WorldWideScience

Sample records for plasma focus type

  1. A model for plasma evolution in Filipov type plasma focus facilities

    International Nuclear Information System (INIS)

    Siahpoush, V.; Sobhanian, S.; Tafreshi, M. A.; Lamehi, M.

    2003-01-01

    A model is presented in this paper for the evolution of plasma in Filipov type plasma focus facilities. With the help of this model, one can predict some of the main parameters of the produced plasma and obtain the optimized geometrical an physical properties (anode radius and length, gas pressure, capacitance, bank energy etc) for the primary design purposes. The results obtained by this model will be compared with the experimental data obtained from the 90 kJ plasma focus facility D ena

  2. An investigation of the plasma behaviour in a Filippov type plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Mahabadi, T D [Plasma Physics Research Center, I.A.U, PO Box 14665-678, Tehran (Iran, Islamic Republic of); Tafreshi, M A [School of Plasma Physics and Nuclear Fusion, Institute of Nuclear Science and Technology, AEOI, PO Box 14155-1339, Tehran (Iran, Islamic Republic of)

    2007-09-15

    Plasma behaviour in the 90 kJ Filippov type plasma focus (PF) device Dena, is studied both experimentally and theoretically. The latest experimental data obtained by the use of the Dena facility are presented. Then the experimental data are compared with the simulated data obtained through the ML model. This study shows that the ML model, to a good extent, is capable of predicting the plasma behaviour in the Filippov type PF. The experimental and the theoretical results show that the increment of the discharge voltage leads to an almost linear decrement of the pinch time. It is also shown that the increment of the pressure leads to a decrement of the current sheath expansion velocity. Finally, a semiempirical method for determination of the permitted values of the current efficiency factor and the mass shedding factor is presented.

  3. Plasma Focus

    International Nuclear Information System (INIS)

    Bernard, Alain; Jolas, Alain; Garconnet, J.-P.; Mascureau, J. de; Nazet, Christian; Coudeville, Alain; Bekiarian, Andre.

    1977-01-01

    The present report is the edition of the lectures given in a conference on the Focus experiment held at the Centre d'etudes de Limeil, on Oct. 1975. After a survey of the early laboratories one will find the main results obtained in Limeil concerning interferometry, laser scattering, electric and magnetic-measurements, X-ray and neutron emission and also the possible use of explosive current generators instead of capacitor banks at high energy levels. The principal lines of future research are given in the conclusion [fr

  4. Adaptation of Sing Lee's model to the Filippov type plasma focus geometry

    International Nuclear Information System (INIS)

    Siahpoush, V; Tafreshi, M A; Sobhanian, S; Khorram, S

    2005-01-01

    A new model for plasma behaviour in Filippov type plasma focus (PF) systems has been described and used. This model is based on the so-called slug model and Sing Lee's model for Mather type PF devices. Using the model, the discharge current and its derivative as a function of time, and the pinch time and the maximum discharge current as a function of pressure, have been predicted. At the end, the predicted data are compared with the experimental data obtained through a Filippov type PF facility with a nominal maximum energy of 90 kJ

  5. Plasma focus breeder

    International Nuclear Information System (INIS)

    Ikuta, Kazunari.

    1981-09-01

    Instead of using linear accelerators, it is possible to breed fissile fuels with the help of high current plasma focus device. A mechanism of accelerating proton beam in plasma focus device to high energy would be a change of inductance in plasma column because of rapid growth of plasma instability. A possible scheme of plasma focus breeder is also proposed. (author)

  6. Study the Output Characteristics of a 90 kJ Filippove-Type Plasma Focus

    Science.gov (United States)

    Sadat Kiai, S. M.; Talaei, A.; Adlparvar, S.; Zirak, A.; Elahi, M.; Safarian, A.; Farhangi, S.; Alhooie, S.; Dabirzadeh, A. A.; Khalaj, M. M.; Mahlooji, M. S.; Talaei, M.; KaKaei, S.; Sheibani, S.; Kashani, A.; Zahedi, F.

    2010-08-01

    The output characteristics of a Filippove-Type plasma focus "Dena" (288 μF, 25 kV, 90 kJ) is numerically investigated by considering the voltage, current, current derivative, and maximum current as a function of capacitor bank energy in the constant Argon gas pressure and compared to the experiment. It is shown that increase on the bank energy leads to the increment on the maximum current and decrement on the pinch time.

  7. High energy ions and energetic plasma irradiation effects on aluminum in a Filippov-type plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Roshan, M.V. [National Institute of Education, Nanyang Technological University, 1 Nanyang Walk, Singapore 637616 (Singapore)], E-mail: mroshan20@yahoo.com; Rawat, R.S. [National Institute of Education, Nanyang Technological University, 1 Nanyang Walk, Singapore 637616 (Singapore); Babazadeh, A.R.; Emami, M.; Sadat Kiai, S.M. [Plasma Physics Research Center, AEOI, 14155-1339 Tehran (Iran, Islamic Republic of); Verma, R.; Lin, J.J.; Talebitaher, A.R.; Lee, P.; Springham, S.V. [National Institute of Education, Nanyang Technological University, 1 Nanyang Walk, Singapore 637616 (Singapore)

    2008-12-30

    High energy ions and energetic plasma irradiation of aluminum cathode inserts have been accomplished in nitrogen and argon filled plasma focus device. The Filippov-type plasma focus facility, Dena, with 288 {mu}F capacitor bank and charging voltage of 25 kV (90 kJ maximum storage energy) was first optimized for strong ion beam generation for nitrogen and argon gases by maximizing hard X-ray emission efficiency. X-ray diffraction analysis as well as scanning electron microscopy along with energy dispersive X-ray spectroscopy carried out to study the structural, morphological and compositional profile of the treated samples. Change in preferred orientation, emergence of meta-stable phases, generation of copper micro-droplets, and production of cracks across the sample are demonstrated and discussed. The micro-hardness measurements in Vickers scale reveal that after ion irradiation, the surface hardness of samples is reduced.

  8. Studies of the Hard X-ray Emission from the Filippov Type Plasma Focus Device, Dena

    Science.gov (United States)

    Tafreshi, M. A.; Saeedzadeh, E.

    2006-12-01

    This article is about the characteristics of the hard X-ray (HXR) emission from the Filippov type plasma focus (PF) device, Dena. The article begins with a brief presentation of Dena, and the mechanism of the HXR production in PF devices. Then using the differential absorption spectrometry, the energy resolved spectrum of the HXR emission from a 37 kJ discharge in Dena, is estimated. The energy flux density and the energy fluence of this emission have also been calculated to be 1.9 kJ cm-2 s-1 and 9.4 × 10-5 J cm-2. In the end, after presentation of radiography of sheep bones and calf ribs, the medical application of the PF devices has been discussed.

  9. Plasma focus matching conditions

    International Nuclear Information System (INIS)

    Soliman, H.M.; Masoud, M.M.; Elkhalafawy, T.A.

    1988-01-01

    A snow-plough and slug models have been used to obtain the optimum matching conditions of the plasma in the focus. The dimensions of the plasma focus device are, inner electrode radius = 2 cm, outer electrode radius = 5.5 cm, and its length = 8 cm. It was found that the maximum magnetic energy of 12.26 kJ has to be delivered to plasma focus whose density is 10 19 /cm 3 at focusing time of 2.55 μs and with total external inductance of 24.2 n H. The same method is used to evaluate the optimum matching conditions for the previous coaxial discharge system which had inner electrode radius = 1.6 cm, outer electrode radius = 3.3 cm and its length = 31.5 cm. These conditions are charging voltage = 12 kV, capacity of the condenser bank = 430 μf, plasma focus density = 10 19 /cm 3 focusing time = 8 μs and total external inductance = 60.32 n H.3 fig., 2 tab

  10. Plasma focus project

    International Nuclear Information System (INIS)

    Sahlin, H.L.

    1975-12-01

    The primary objective of this project is to provide a relatively simple pulsed power source for high density pulsed fusion studies with a variety of DT and other fusion microexplosion targets. The plasma focus operated on DT at 1 MJ should produce greater than or equal to 10 15 DT neutrons per pulse corresponding to 2800 J of nuclear energy release and for low pressure operation and appropriately configured high Z anode center should yield an x-ray burst of about 1000 J with a substantial fraction of this x-ray energy concentrated in the 5-100 kV range. Because of its x-ray and neutron production potential, the operation of the focus as an x-ray source is also under study and an initial design study for a repetitively pulsed 1 MJ plasma focus as a pulsed neutron materials testing source has been completed. The plasma focus seems particularly appropriate for application as a materials testing source for pulsed fusion reactors, for example, based on laser driven fusion microexplosions. The construction status of the device is described

  11. X-ray and neutron emission studies in a new Filippov type plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Babazadeh, A.R.; Banoushi, A. [Technical University of Amirkabir, Tehran (Iran, Islamic Republic of). Dept. of Physics; Roshan, M.V.; Habibi, H.; Nasiry, A.; Memarzadeh, M.; Lamehi, M.; Kiai, S.M. Sadat [Atomic Energy Organization of Iran (AEOI), Tehran (Iran, Islamic Republic of). Nuclear Fusion Research Center

    2002-03-01

    We have performed experimental comparative studies of the X-ray and neutron emission generated by the new Filippov-type plasma focus 'Dena', (90 kJ, 25 kV, 288{mu}F) in the pressure range of 0.6-1 torr. Time-integrated and time-resolved detectors, together with an X-ray pin-hole camera, along with a Be filter of 10{mu}m thickness have been used. For a working gas of neon and a at insert anode, the maximum soft and hard X-rays (SXR-HXR) yield obtained was 16 V and 1.5 V/shot over a 4{pi} solid angle, respectively, for a charging voltage range of 16-20 kV. As for the argon gas, the similar results such as 3.5 and 2 V/shot have been found, leading to a total conversion efficiency of X-ray emission of 0.09 % (for neon) and 0.03 % (for argon) of the stored energy. These efficiencies have been improved by the employment of a conic insert anode up to 0.4% and 0.1%. With deuterium puffing gas and a at insert anode, the maximum emission yield has been found to be 2.5 V for SXR and 1 V for HXR/shot which produce an ultimate emission profile width (FWHM) of 70-90 ns for X-rays and neutrons, giving rise to a maximum neutron yield of 1.2 x 10{sup 9}. Nevertheless, the maximum yield has been increased up to 5.5 times with the conic insert anode. In order to increase the neutron yield, we have introduced a krypton admixture to the deuterium filling gas and found that, for a krypton pressure of about 0.1 torr, the neutron yield increases by a factor of 3.5 for the flat insert and 1.5 for the conic insert anodes. (author)

  12. Dose-current discharge correlation analysis in a Mather type Plasma Focus device for medical applications

    Science.gov (United States)

    Sumini, M.; Mostacci, D.; Tartari, A.; Mazza, A.; Cucchi, G.; Isolan, L.; Buontempo, F.; Zironi, I.; Castellani, G.

    2017-11-01

    In a Plasma Focus device the plasma collapses into the pinch where it reaches thermonuclear conditions for a few tens of nanoseconds, becoming a multi-radiation source. The nature of the radiation generated depends on the gas filling the chamber and the device working parameters. The self-collimated electron beam generated in the backward direction with respect to the plasma motion is one of the main radiation sources of interest also for medical applications. The electron beam may be guided against a high Z material target to produce an X-ray beam. This technique offers an ultra-high dose rate source of X-rays, able to deliver during the pinch a massive dose (up to 1 Gy per discharge for the PFMA-3 test device), as measured with EBT3 GafchromicⒸfilm tissue equivalent dosimeters. Given the stochastic behavior of the discharge process, a reliable on-line estimate of the dose-delivered is a very challenging task, in some way preventing a systematic application as a potentially interesting therapy device. This work presents an approach to linking the dose registered by the EBT3 GafchromicⒸfilms with the information contained in the signal recorded during the current discharge process. Processing the signal with the Wigner-Ville distribution, a spectrogram was obtained, displaying the information on intensity at various frequency scales, identifying the band of frequencies representative of the pinch events and define some patterns correlated with the dose.

  13. Dense Plasma Focus Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hui [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Li, Shengtai [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jungman, Gerard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hayes-Sterbenz, Anna Catherine [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-31

    The mechanisms for pinch formation in Dense Plasma Focus (DPF) devices, with the generation of high-energy ions beams and subsequent neutron production over a relatively short distance, are not fully understood. Here we report on high-fidelity 2D and 3D numerical magnetohydrodynamic (MHD) simulations using the LA-COMPASS code to study the pinch formation dynamics and its associated instabilities and neutron production.

  14. Stability of expanded plasma focus

    International Nuclear Information System (INIS)

    Soliman, H.M.

    1994-01-01

    In this study, the stabilization of the expanded plasma focus formed by 4.5 kJ plasma focus device of Mather type by magnetic field is presented. The experimental results of the induced axial magnetic field and electric probe measurements of the expanded plasma focus show that, the plasma consists of three plasmoids, electron temperature measurements off the plasmoids at a point close to the muzzle are 26 eV, 30 eV and 27 eV respectively and the electron densities are 6.6 x 10 14 , 6.1 x 10 14 / cm 3 respectively. The presence of external axial magnetic field (B 2 = 1.6 kg) at the mid distance between the breech and the muzzle has a less effect on the stability of expanded focus and it causes a restriction for the plasma motion. the electron temperature of the three plasmoids are found to increase in that case by 23%, 18.5% respectively. When this axial magnetic field is applied at the muzzle end, it leads to a more stable expanded plasma focus which consists mainly of one plasmoid with electron temperature of 39 eV and density of 3.4 x 10 14 / cm 3 . 5 figs

  15. Energy spectrum of argon ions emitted from Filippov type Sahand plasma focus

    International Nuclear Information System (INIS)

    Mohammadnejad, M.; Pestehe, S. J.; Mohammadi, M. A.

    2013-01-01

    The energy and flux of the argon ions produced in Sahand plasma focus have been measured by employing a well-designed Faraday cup. The secondary electron emission effects on the ion signals are simulated and the dimensions of Faraday cup are optimized to minimize these effects. The measured ion energy spectrum is corrected for the ion energy loss and charge exchange in the background gas. The effects of the capacitor bank voltage and working gas pressure on the ion energy spectrum are also investigated. It has been shown that the emitted ion number per energy increases as the capacitor bank voltage increases. Decreasing the working gas pressure leads to the increase in the number of emitted ion per energy

  16. Neutron production with mixture of deuterium and krypton in Sahand Filippov type plasma focus facility

    International Nuclear Information System (INIS)

    Mohammadi, M.A.; Sobhanian, S.; Rawat, R.S.

    2011-01-01

    This Letter reports the order of magnitude enhancement in neutron yield from Sahand plasma focus device with krypton seeded deuterium operation. The highest average neutron yield of 2.2x10 9 neutrons per shot was achieved at 1.00 Torr deuterium with 3% krypton which is higher than the best average neutron yield of 3.18x10 8 neutrons per shot for pure deuterium operation. Estimation of average neutron energy showed that the maximum and minimum average energies are 2.98±0.6 MeV at 16 kV in 0.25 Torr deuterium with 3% Kr and 2.07±0.2 MeV at 18 kV operation in 0.5 Torr deuterium with 3% Kr, respectively. The anisotropy of neutron emission from Sahand DPF showed that the neutrons are produced mainly by beam-target mechanisms. -- Highlights: → The highest average neutron yield of 2.2x10 9 neutrons per shot was achieved at mixture of deuterium and krypton. → In the krypton seeding of deuterium also anisotropy of neutron emission deuterium is found. → The krypton seeding of deuterium made the neutron emission more reliable over wider operating pressure ranges.

  17. A study of plasma focus

    International Nuclear Information System (INIS)

    Hirano, Katsumi; Majima, Kazuo

    1976-01-01

    The behavior of the plasma acceleration between electrodes, the phenomena due to the pinch effect at the top of the electrodes and the neutron emission mechanism were experimentally studied. The plasma focus device was a Mather type coaxial discharge device, and the instruments used for the present purpose were a Rogoski coil, an image converter camera, a scintillation detector and a silver foil activation counter. The results of the present experiment were as follows. Plasma focus was not definitely made under the same condition. When the focus was seen, a dip was observed in the discharge wave form, and the emissions of X-ray and neutrons were detected. The angular anisotropy of neutron emission was observed, and corresponds to a beam target model. The phenomena showing the occurrence of focus were seen, when the current sheet was produced at a delayed time after discharge, and arrived at the muzzle with large velocity. The relation between the number of emitted neutrons and the velocity of the current sheet was obtained, whereas no systematic relation exists between the number of emitted neutrons and the velocity of pinch. When the focus was not observed, no dip was seen in current wave form, and the emissions of X-ray and neutrons were not detected. The reason of no focus was considered. (Kato, T.)

  18. Magnetic tearing in plasma focus

    International Nuclear Information System (INIS)

    Sharkawy, W.

    1994-01-01

    A plasma focus device used is Mather type filled with hydrogen gas at pressure between 0.1 and 1 torr. When connected to a large capacitor ≤10 KV a discharge is started with peak current 100 KA. Under the influence of the radial electric field E r , due to the potential between electrodes, and B φ the plasma will drift in the axial direction with velocity cE r /B φ . An induced axial magnetic field B z has been detected which due to sheath velocity. A propagation of magnetosonic wave has been observed with velocity ≅10 3 m sec -1 . Such a wave might be excited when the magnetic pressure is much greater than the plasma kinetic pressure B 2 /8π>nKT. Assuming (MHD) to be stable, Tearing model was driven which generally has smaller growth rates than (MHD) modes. Using the designed theoretical model and the plasma parameters the electron energy dΦ/dt=Ba 2 /τ R was calculated to be 2.22 KeV, which is comparable with that detected from X-ray measurements. (author)

  19. Instabilities in the plasma focus

    International Nuclear Information System (INIS)

    Kaeppeler, H.J.

    1975-03-01

    The plasma focus was studied by many research teams in view of a possible approach to controlled thermonuclear fusion. Though it is questionable whether the plasma focus will ever lead to a fusion reactor, it nevertheless constitutes a strong source of neutron, X- and gamma radiation for simulating fusion reactor conditions. Furthermore, the plasma focus yields very high temperatures (10 7 K) and densities (> 10 19 cm -3 ) and thus provides interesting conditions for the study of high density plasmas. This review paper starts with a description of the compression stage of the focussing plasma, using a snow-plough model. It is shown that sophisticated MHD calculations substantiate the snowplough theory, but are not suited to describe the phenomena in the final compressed stage. For this purpose, a particle-in-cell calculation is employed, yielding a beam-beam collision model for the neutron production. Experimental evidence indicates that neutron production is associated with the appearence of m = O instabilities and is the direct result of collisions between anomalously accelerated ions. One of the mechanisms of ion acceleration are strong local electric fields. Another possible mechanism can bee seen in beam-plasma instabilities caused by runaway electrons. The analytical derivation of the dispersion relation for plasma focus conditions including runaway effect is discussed (orig.) [de

  20. Technology of a small plasma focus

    International Nuclear Information System (INIS)

    Lee, S.

    1990-01-01

    This paper reviews plasma focus technology, including the underlying dynamic and energy balance theory, scaling of the neutron yield, cost effectiveness of the design, as well as the main subsystems, e.g., capacitor bank, spark-gap switch and triggering electronics, the plasma focus tube, some simple diagnostics, and a high-voltage charger. It discusses the range of densities and temperatures available with a small plasma focus, and the type of experiments and applications that can be carried out with it. 61 refs, 21 figs

  1. Some optical diagnostics for the plasma focus

    International Nuclear Information System (INIS)

    Korzhavin, V.M.

    1980-01-01

    Some aspects of studying plasma focus dynamics are reported. Particular efforts were made to develop an infrared (IR) diagnostics. The plasma focus is formed in a discharge chamber, when shock waves and plasma sheath cumulate on the axis as a result of the break-down of filling gas by the application of high voltage. The current J was measured with a Rogovsky coil, and the voltage U was measured with a capacitor divider. The current derivative was measured with magnetic probes, and X-ray and neutron emission intensities were measured with a plastic scintillator. The total neutron yield were measured by the activation method. The time-integrated soft X-ray pictures of plasma focus were taken with a pin-hole camera. The formation and disruption of plasma focus were studied by multi-picture speed photography. Laser interferometry was used to study the time-space distribution of plasma density. For the study of turbulence phenomena in plasma focus, a new type IR detector was employed. The results of measurements suggest that there exists some superthermal radiation during the second compression of plasma focus, but it is not so strong. (Kato, T.)

  2. Plasma focusing in coaxial gun

    International Nuclear Information System (INIS)

    Soliman, H.M.; Masoud, M.M.; El-Khalafawy, T.

    1986-01-01

    A capacitor bank has been discharged between two coaxial electrodes of 6.6 cm outer diameter, 3.2 cm inner diameter and length of 31.5 cm. filled with hydrogen gas at pressure of 310 μHg. Results show that, the axial and radial plasma current reach a maximum value at a position adjacent to the gun muzzle, at which the plasma focus occurs. The measurement of the electron temperature and density and azimuthal electric field along the axis of the expansion chamber, gives a maximum value at z∼18 cm from the gun muzzle, while the axial plasma current and velocity has a minimum value at that position. These results indicate that a second point of a plasma focus has been formed at z∼18 cm from the gun muzzle, along the axis of the expansion chamber

  3. Catastrophe in plasma focus evolution

    International Nuclear Information System (INIS)

    Ikuta, Kazunari.

    1984-07-01

    A theory of generating strong electric field in a dense plasma column in plasma focus is established by applying the formula for the electron thermal conductivity in destroyed magnetic surfaces like those in tokamaks. The origin of the electric field may be from abrupt rise of plasma resistivity when the irregularity of magnetic field is weak. However, the electric field can be from the inductive origin in case the irregularity attains a certain level. Both origin should be mixed up depending on the magnitude of the irregularity. (author)

  4. Global parameter optimization of a Mather-type plasma focus in the framework of the Gratton–Vargas two-dimensional snowplow model

    International Nuclear Information System (INIS)

    Auluck, S K H

    2014-01-01

    Dense plasma focus (DPF) is known to produce highly energetic ions, electrons and plasma environment which can be used for breeding short-lived isotopes, plasma nanotechnology and other material processing applications. Commercial utilization of DPF in such areas would need a design tool that can be deployed in an automatic search for the best possible device configuration for a given application. The recently revisited (Auluck 2013 Phys. Plasmas 20 112501) Gratton–Vargas (GV) two-dimensional analytical snowplow model of plasma focus provides a numerical formula for dynamic inductance of a Mather-type plasma focus fitted to thousands of automated computations, which enables the construction of such a design tool. This inductance formula is utilized in the present work to explore global optimization, based on first-principles optimality criteria, in a four-dimensional parameter-subspace of the zero-resistance GV model. The optimization process is shown to reproduce the empirically observed constancy of the drive parameter over eight decades in capacitor bank energy. The optimized geometry of plasma focus normalized to the anode radius is shown to be independent of voltage, while the optimized anode radius is shown to be related to capacitor bank inductance. (paper)

  5. Plasma-focused cyclic accelerators

    International Nuclear Information System (INIS)

    Mondelli, A.A.; Chernin, D.P.

    1985-01-01

    The use of ambient plasma to neutralize the transverse forces of an intense particle beam has been known for many years. Most recently, the so-called ion-focused regime (IFR) for beam propagation has been used as a means of focusing intense electron beams in linear accelerators and suggested for injecting an electron beam across magnetic field lines into a high-current cyclic accelerator. One technique for generating the required background plasma for IFR propagation is to use a laser to ionize ambient gas in the accelerator chamber. This paper discusses an alternative means of plasma production for IFR, viz. by using RF breakdown. For this approach the accelerator chamber acts as a waveguide. This technique is not limited to toroidal accelerators. It may be applied to any accelerator or recirculator geometry as well as for beam steering and for injection or extraction of beams in closed accelerator configurations

  6. Axial sheath dynamics in a plasma focus

    International Nuclear Information System (INIS)

    Soliman, H.M.; El-Khalafawy, T.A.; Masoud, M.M.

    1990-01-01

    This paper presents the result of investigation with a 10 kJ Mather type plasma focus. It is operated in hydrogen gas at ambient pressure of 0.15--1 torr and charging voltage of 8--11 kV. Radial distribution of the current sheath density with axial distance has been estimated. Plasma rotation in the expansion chamber in the absence of external magnetic field has been detected. A plasma flare from the plasma focus region propagating in the radial direction has been observed. Streak photography shows two plasma streams flowing simultaneously out of the muzzle. The mean energy of the electron beam ejected from the pinch region of the focused plasma, was measured by retarding field analyzer to be 0.32 keV. The electron temperature of the plasma focus at peak compression was determined by measuring the X-ray intensity as a function of absorber thickness at a distance of 62 cm from the focus. The electron temperature has been found to 3 keV

  7. Plasma-focused cyclic accelerators

    International Nuclear Information System (INIS)

    Mondelli, A.A.; Chernin, D.P.

    1985-01-01

    The use of ambient plasma to neutralize the transverse forces of an intense particle beam has been known for many years. Most recently, the so-called ion-focused regime (IFR) for beam propagation has been used as a means of focusing intense electron beams in linear accelerators and suggested for injecting an electron beam across magnetic field lines into a high-current cyclic accelerator. One technique for generating the required background plasma for IFR propagation is to use a laser to ionize ambient gas in the accelerator chamber. For cyclic accelerators a technique is required for carrying the plasma channel and the beam around a bend. Multiple laser-generated channels with dipole magnetic fields to switch the beam from one channel to the next have been tested at Sandia. This paper discusses an alternative means of plasma production for IFR, viz. by using rf breakdown. For this approach the accelerator chamber acts as a waveguide. With a suitable driving frequency, a waveguide mode can be driven which has its peak field intensity on the axis with negligible fields at the chamber walls. The plasma production and hence the beam propagation is thereby isolated from the walls. This technique is not limited to toroidal accelerators. It may be applied to any accelerator or recirculator geometry as well as for beam steering and for injection or extraction of beams in closed accelerator configurations

  8. The Upgraded Plasma Focus Installation > - The Installation >

    International Nuclear Information System (INIS)

    Krokhin, O.N.; Nikulin, V.Ya.; Babenko, B.A.; Gorbunov, D.N.; Gurei, A.E.; Kalachev, N.V.; Kozlova, T.A.; Malafeev, Yu.S.; Polukhin, S.N.; Sychev, A.A.; Tikhomirov, A.A.; Tsybenko, S.P.; Volobuev, I.V.

    1999-01-01

    The paper presents the upgraded plasma focus installation > - the installation > and some preliminary experimental results. The total energy stored in capacity bank is now 400 kJ, current - 5 MA with the rise time 3.5 μs. The investigation is targeted on the study of near electrode processes and its influence on plasma dynamics in a special operating regime of Filippov type PF - Hard X-ray regime. (author)

  9. EDITORIAL: Focus on Plasma Medicine

    Science.gov (United States)

    Morfill, G. E.; Kong, M. G.; Zimmermann, J. L.

    2009-11-01

    'Plasma Healthcare' is an emerging interdisciplinary research topic of rapidly growing importance, exploring considerable opportunities at the interface of plasma physics, chemistry and engineering with life sciences. Some of the scientific discoveries reported so far have already demonstrated clear benefits for healthcare in areas of medicine, food safety, environmental hygiene, and cosmetics. Examples include ongoing studies of prion inactivation, chronic wound treatment and plasma-mediated cancer therapy. Current research ranges from basic physical processes, plasma chemical design, to the interaction of plasmas with (i) eukaryotic (mammalian) cells; (ii) prokaryotic (bacteria) cells, viruses, spores and fungi; (iii) DNA, lipids, proteins and cell membranes; and (iv) living human, animal and plant tissues in the presence of biofluids. Of diverse interests in this new field is the need for hospital disinfection, in particular with respect to the alarming increase in bacterial resistance to antibiotics, the concomitant needs in private practices, nursing homes etc, the applications in personal hygiene—and the enticing possibility to 'design' plasmas as possible pharmaceutical products, employing ionic as well as molecular agents for medical treatment. The 'delivery' of the reactive plasma agents occurs at the gaseous level, which means that there is no need for a carrier medium and access to the treatment surface is optimal. This focus issue provides a close look at the current state of the art in Plasma Medicine with a number of forefront research articles as well as an introductory review. Focus on Plasma Medicine Contents Application of epifluorescence scanning for monitoring the efficacy of protein removal by RF gas-plasma decontamination Helen C Baxter, Patricia R Richardson, Gaynor A Campbell, Valeri I Kovalev, Robert Maier, James S Barton, Anita C Jones, Greg DeLarge, Mark Casey and Robert L Baxter Inactivation factors of spore-forming bacteria using low

  10. Optimum Design of Plasma Focus

    International Nuclear Information System (INIS)

    Ramos, Ruben; Gonzalez, Jose; Clausse, Alejandro

    2000-01-01

    The optimum design of Plasma Focus devices is presented based in a lumped parameter model of the MHD equations.Maps in the design parameters space are obtained, which determine the length and deuterium pressure required to produce a given neutron yield.Sensitivity analyses of the main effective numbers (sweeping efficiencies) was performed, and lately the optimum values were determined in order to set a basis for the conceptual design

  11. Neutron emission from deuterium plasma focus

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Banjanac, R.; Dragic, A.; Djordjevic, D.; Joksimovic, D.; Maric, Z.; Udovicic, V.; Vukovic, J.

    1998-01-01

    The anisotropy of emitted neutrons is investigated on a small 'Mather-type' plasma focus device (PF). This problem is of importance for determining the nature of the fusion reaction mechanisms. Mica detectors together with thick uranium foils were used for both detection and angular distribution measurements of the neutrons. Previously, the annealing of the detectors was done and measured after the irradiation with neutrons from Am-Be source. Also, annealing ability of H-plasma focus has been tested. Geometry of detectors in both experiments was the same. (authors)

  12. Application of plasma focus device to compression of toroidal plasma

    International Nuclear Information System (INIS)

    Ikuta, Kazunari

    1980-01-01

    A new concept of compressing a toroidal plasma using a plasma focus device is considered. Maximum compression ratio of toroidal plasma is determined merely by the initial density ratio of the toroidal plasma to a sheet plasma in a focus device because of the Rayleigh-Taylor instability. An initiation senario of plasma-linear is also proposed with a possible application of this concepts to the creation of a burning plasma in reversed field configurations, i.e., burning plasma vortex. (author)

  13. Investigation of Plasma Facing Components in Plasma Focus Operation

    Science.gov (United States)

    Roshan, M. V.; Babazadeh, A. R.; Kiai, S. M. Sadat; Habibi, H.; Mamarzadeh, M.

    2007-09-01

    Both aspects of the plasma-wall interactions, counter effect of plasma and materials, have been considered in our experiments. The AEOI plasma focus, Dena, has Filippov-type electrodes. The experimental results verify that neutron production increases using tungsten as an anode insert material, compared to the copper one. The experiments show decrement of the hardness of Aluminum targets outward the sides, from 135 to 78 in Vickers scale. The sputtering yield is about 0.0065 for deuteron energy of 50 keV.

  14. Invited paper: Plasma focus in China

    International Nuclear Information System (INIS)

    Jinji, Y.

    1983-01-01

    Plasma focus research in China began in the seventies. There are now 3 devices in two institutions, Tsinghua University in Beijing and the Institute of Mining and Metallurgy in Changsha. The research works can be divided into two groups: the engineering problems related to plasma focus devices and the plasma phenomena and process of the focus. Under the first subject, insulation and plasma spark gaps are studied. By casting silicon rubber onto the ends of the transmission cable, the length of insulation can be appreciably reduced. With the method of simulating charges, the electric field distribution of a field distortion type spark gap was calculated. Comparison of the field distribution before and after triggering was represented. It shows that the electric field strength of the gap after triggering may reach 14-80 times as high as that before triggering. Thus the characteristic of the gap may be improved remarkably. In respect of the phenomena of the plasma focus, neutron emission and X-ray emission were measured. It was shown that the proportion of X-ray with higher energy depends upon the material of the inner electrode. Two kinds of stud materials, tungsten and molybendum, were adopted. Measured results of the distribution of X-ray energy were represented respectively for the two materials used. Evidently, the distribution changed with the inserted materials

  15. Energy coupling in the plasma focus

    International Nuclear Information System (INIS)

    Wainwright, T.E.; Pickles, W.L.; Sahlin, H.L.; Price, D.F.

    1979-01-01

    Experiments have been performed with a 125-kJ plasma focus to investigate mechanisms for rapid coupling of inductively-stored energy into plasmas. The coupling can take place through the formation of an electron or ion beam that deposits its energy in a target or directly by the penetration of the magnetic field into a resistive plasma. Some preliminary results from experiments of both types are described. The experiments use a replaceable conical anode tip that is intended to guide the focus to within a few millimeters of the axis, where it can suddenly deliver energy either to a small target or to particles that are accelerated. X-ray and fast-ion diagnostics have been used to study the effects

  16. Investigation of a staged plasma-focus apparatus

    International Nuclear Information System (INIS)

    Lee, J.H.; McFarland, D.R.; Harries, W.L.

    1978-01-01

    A new staged plasma-focus geometry combining two Mather-type plasma-focus guns has been constructed, and the current-sheet dynamics investigated. The production of simultaneous pairs of plasma foci has been achieved. The intensities of X-ray and fusion-neutron emission were measured and found to agree with the scaling law for a plasma focus. Advantages of this new geometry include the possibility of using plasma-focus type pinches in multiple arrays at power levels beyond the validity regime of the current scaling law for a single gun. (author)

  17. Design a 10 kJ IS Mather Type Plasma Focus for Solid Target Activation to Produce Short-Lived Radioisotopes 12C(d,n)13N

    Science.gov (United States)

    Sadat Kiai, S. M.; Adlparvar, S.; Sheibani, S.; Elahi, M.; Safarien, A.; Farhangi, S.; Zirak, A. R.; Alhooie, S.; Mortazavi, B. N.; Khalaj, M. M.; Khanchi, A. R.; Dabirzadeh, A. A.; Kashani, A.; Zahedi, F.

    2010-10-01

    A 10 kJ (15 kV, 88 μF) IS (Iranian Sun) Mather type plasma focus device has been studied to determine the activity of a compound exogenous carbon solid target through 12C(d,n)13N nuclear reaction. The produced 13N is a short-lived radioisotope with a half-life of 9.97 min and threshold energy of 0.28 MeV. The results indicate that energetic deuterons impinging on the solid target can produce yield of = 6.7 × 10-5 with an activity of A = 6.8 × 104 Bq for one plasma focus shut and A ν = 4 × 105 Bq for 6 shut per mint when the projectile maximum deuterons energy is E max = 3 MeV.

  18. A lumped parameter model of plasma focus

    International Nuclear Information System (INIS)

    Gonzalez, Jose H.; Florido, Pablo C.; Bruzzone, H.; Clausse, Alejandro

    1999-01-01

    A lumped parameter model to estimate neutron emission of a plasma focus (PF) device is developed. The dynamic of the current sheet is calculated using a snowplow model, and the neutron production with the thermal fusion cross section for a deuterium filling gas. The results were contrasted as a function of the filling pressure with experimental measurements of a 3.68 KJ Mather-type PF. (author)

  19. Plasma focus system: Design, construction and experiments

    International Nuclear Information System (INIS)

    Alacakir, A.; Akguen, Y.; Boeluekdemir, A. S.

    2007-01-01

    The aim of this work is to construct a compact experimental system for fusion research. The design, construction and experiments of the 3 kJ Mather type plasma focus machine is described. This machine is established for neutron yield and fast neutron radiography by D-D reaction which is given by D + D→ 3 He (0.82 MeV) + n (2.45 MeV) . Investigation of the geometry of plasma focus machine in the presence of high voltage drive and vacuum system setup is shown. 108 neutron per pulse and 200 kA peak current is obtained for many shots. Scintillator screen for fast neutron imaging, sensitive to 2.45 MeV neutrons, is also manufactured in our labs. Structural neutron shielding computations for safety is also completed

  20. Development of TPF-1 plasma focus for education

    Science.gov (United States)

    Picha, R.; Promping, J.; Channuie, J.; Poolyarat, N.; Sangaroon, S.; Traikool, T.

    2017-09-01

    The plasma focus is a device that uses high voltage and electromagnetic force to induce plasma generation and acceleration, in order to cause nuclear reactions. Radiation of various types (X-ray, gamma ray, electrons, ions, neutrons) can be generated using this method during the pinch phase, thus making the plasma focus able to serve as a radiation source. Material testing, modification, and identification are among the current applications of the plasma focus. Other than being an alternative option to isotopic sources, the plasma focus, which requires multidisciplinary team of personnel to design, operate, and troubleshoot, can also serve as an excellent learning device for physics and engineering students in the fields including, but not limited to, plasma physics, nuclear physics, electronics engineering, and mechanical engineering. This work describes the parameters and current status of Thai Plasma Focus 1 (TPF-1) and the characteristics of the plasma being produced in the machine using a Rogowski coil.

  1. Plasma lenses for focusing relativistic electron beams

    International Nuclear Information System (INIS)

    Govil, R.; Wheeler, S.; Leemans, W.

    1997-01-01

    The next generation of colliders require tightly focused beams with high luminosity. To focus charged particle beams for such applications, a plasma focusing scheme has been proposed. Plasma lenses can be overdense (plasma density, n p much greater than electron beam density, n b ) or underdense (n p less than 2 n b ). In overdense lenses the space-charge force of the electron beam is canceled by the plasma and the remaining magnetic force causes the electron beam to self-pinch. The focusing gradient is nonlinear, resulting in spherical aberrations. In underdense lenses, the self-forces of the electron beam cancel, allowing the plasma ions to focus the beam. Although for a given beam density, a uniform underdense lens produces smaller focusing gradients than an overdense lens, it produces better beam quality since the focusing is done by plasma ions. The underdense lens can be improved by tapering the density of the plasma for optimal focusing. The underdense lens performance can be enhanced further by producing adiabatic plasma lenses to avoid the Oide limit on spot size due to synchrotron radiation by the electron beam. The plasma lens experiment at the Beam Test Facility (BTF) is designed to study the properties of plasma lenses in both overdense and underdense regimes. In particular, important issues such as electron beam matching, time response of the lens, lens aberrations and shot-to-shot reproducibility are being investigated

  2. The heating of plasma focus electrodes

    International Nuclear Information System (INIS)

    Angeli, E; Frignani, M; Mannucci, S; Rocchi, F; Sumini, M; Tartari, A

    2006-01-01

    Plasma focus (PF) technology development today is strictly related to the possibility of a high frequency repetitive working regime. One of the more relevant obstacles to this goal is the heating of structural components due to direct interaction with plasma. In this paper, temperature decay measurements of the inner electrode of a 7 kJ Mather type PF are presented. Data from several series of shots at different bank energies are analysed and compared with theoretical and numerical models. Two possible scale laws are derived from the experimental data to correlate thermal deposition with bank energy. It is found that a fraction of about 10% of total energy is released to the inner electrode. Finally, after some considerations about the cooling and heating mechanisms, an analysis on maximum temperature sustained by materials is presented

  3. Anode plasma and focusing reb diodes

    International Nuclear Information System (INIS)

    Goldstein, S.A.; Swain, D.W.; Hadley, G.R.; Mix, L.P.

    1975-01-01

    The use of electrical, optical, x-ray, and particle diagnostics to characterize the production of anode plasma and to monitor its influence on beam generation and focusing is reviewed. Studies using the Nereus accelerator show that after cathode turn-on, deposition of several kJ/gm on the anode is necessary before ions from hydrocarbons, adsorbed gases, and heavier metallic species are detected. The actual time at which ions are liberated depends on several factors, one of which is the specific heat of the anode substrate. Once formed, anode ions cross the A-K gap (with an energy equal to the diode voltage) and interact with the cathode to produce an axially peaked beam profile, a ''pinch'' which does not follow the critical current criterion. Experiments with externally generated anode plasma show that this type of pinch can be attracted to localized areas on the anode. Preliminary observations on Hydra indicate the anode plasma composition is similar to that on Nereus. The effect of this plasma on pinch dynamics currently is under investigation

  4. Sausage instability threshold in a low energy plasma focus

    International Nuclear Information System (INIS)

    Zakaullah, M.; Nasir, M.; Khattak, F.Y.; Murtaza, G.

    1993-01-01

    Development of sausage instability (m = 0 mode) is studied in a small low energy Mather-type plasma focus. A shadow graphic study of the current sheath has shown that the focused plasma necks off during the radial phase before the maximum compression. This may indicate the lowering of the instability threshold. Three hook-type structures are observed which may not be due to the multifoci formation. The bubble shape structure is observed to be developed in the expansion phase. (author)

  5. Plasma focus - a pulsed radiation source

    International Nuclear Information System (INIS)

    Blagoev, Alexandar; Zapryanov, Stanislav; Gol'tsev, Vasilii; Gemishev, Orlin

    2014-01-01

    The article is devoted to the applications of plasma focus (PF) in radiobiology. Briefly describes the principle of operation of the device and the parameters of the PF type 'Mader' at the Physics Department of the University. Phase pinch discharge zones appear hot and dense plasma, which is a source of X-ray and neutron pulse when the working gas is deuterium. These radiations are essential for biological applications. Besides these bundles are obtained from accelerated charged particles and shock wave of ionized gas. Described are some of the contributions of other authors using PF in radiobiology. Given the results in the exposure of living organisms with soft X-ray emission of PF. We examined the viability of the cells of the two types of yeasts, after irradiation with X-rays at a dose of 65 mSv, where no change was found on the performance. It is shown that soft X-ray radiation doses on the order of tens of mSv, cause a significant change in the productivity of the electronic transport in the photosynthetic apparatus of Chlamydomonas reinhardtii. Trichoderma reesei M7 shows remarkable vitality irradiation with substantial doses of hard X-ray radiation (tens Sv). Appear endoglyukonazata changes in the protein component and the residual mass

  6. Structural Analysis of Extended Plasma Focus Chamber

    International Nuclear Information System (INIS)

    Mohd Azhar Ahmad; Abdul Halim Baijan; Siti Aiasah Hashim

    2016-01-01

    Accelerator Development Centre (ADC) of Nuclear Malaysia intends to upgrade the plasma focus device. It involves the extension part placed on top of the existing plasma focus vacuum chamber. This extended vacuum chamber purposely to give an extra space in conducting experiments on the existing plasma focus chamber. The aim of upgrading the plasma focus device is to solve the limitation in research and analysis of sample due to its done in an open system that cause analysis of samples is limited and less optimal. This extended chamber was design in considering the ease of fabrication as well as durability of its structural. Thus, this paper discusses the structural analysis in term of pressure loading effect in extended chamber. (author)

  7. Experimental investigation of the operating characteristic of a plasma focus

    International Nuclear Information System (INIS)

    Rapp, H.

    The design of a 60 kJ plasma focus installation of the Mather type for generating a deuterium plasma with fusion conditions is described. The advantages of a plasma focus layout in comparison with the linear z-pinch are explained, and questions which arise from the interaction of energy storage and plasma accelerator are discussed. The conclusions are used as a basis for planning the entire installation and dimensioning the individual components. This is followed by a description of some typical difficulties which can have a negative effect on the operation of the plasma focus and how these problems were overcome. Photographic observation of the acceleration and compression process has provided important information concerning the configuration, structure and velocity of the plasma, which is supplemented by magnetic probe measurements of the variations in current. Additional observations involve measurements of neutron yield, neutron flux anisotropy and the neutron spectrum. A theoretical analysis is also presented

  8. Electron beam production by a plasma focus

    International Nuclear Information System (INIS)

    Smith, J.R.; Luo, C.M.; Schneider, R.F.; Rhee, M.J.

    1984-01-01

    Operation of a plasma focus as a Compact Pulsed Accelerator (CPA) for ions has been previously reported. The CPA consists of: (1) a 15 μF, 3 kJ capacitor, (2) a triggered spark gap, (3) a coaxial transmission line, and (4) a Mather geometry plasma gun. Recently the authors have investigated application of the CPA as an accelerator for electrons. In the previously reported work using the standard Mather plasma gun geometry, ions were accelerated away from the plasma gun and were therefore conveniently extracted for analysis, but electrons were directed into the hollow anode where extraction is blocked by the coaxial transmission line. For investigation of accelerated electrons a new plasma gun design which allows extraction of electrons has been developed. Details of the new plasma gun design and further results of beam diagnostics are discussed

  9. Kinetic Simulations of Dense Plasma Focus Breakdown

    Science.gov (United States)

    Schmidt, A.; Higginson, D. P.; Jiang, S.; Link, A.; Povilus, A.; Sears, J.; Bennett, N.; Rose, D. V.; Welch, D. R.

    2015-11-01

    A dense plasma focus (DPF) device is a type of plasma gun that drives current through a set of coaxial electrodes to assemble gas inside the device and then implode that gas on axis to form a Z-pinch. This implosion drives hydrodynamic and kinetic instabilities that generate strong electric fields, which produces a short intense pulse of x-rays, high-energy (>100 keV) electrons and ions, and (in deuterium gas) neutrons. A strong factor in pinch performance is the initial breakdown and ionization of the gas along the insulator surface separating the two electrodes. The smoothness and isotropy of this ionized sheath are imprinted on the current sheath that travels along the electrodes, thus making it an important portion of the DPF to both understand and optimize. Here we use kinetic simulations in the Particle-in-cell code LSP to model the breakdown. Simulations are initiated with neutral gas and the breakdown modeled self-consistently as driven by a charged capacitor system. We also investigate novel geometries for the insulator and electrodes to attempt to control the electric field profile. The initial ionization fraction of gas is explored computationally to gauge possible advantages of pre-ionization which could be created experimentally via lasers or a glow-discharge. Prepared by LLNL under Contract DE-AC52-07NA27344.

  10. Plasma focus as a pulsed power source

    International Nuclear Information System (INIS)

    Sahlin, H.; McFarland, G.; Barlett, R.; Gullickson, R.

    1975-01-01

    The plasma focus is a remarkable natural phenomena that achieves significant space-time compression of both particle and field energy. Depending on the mode of operation, about 20 percent of the bank energy can be concentrated into the kinetic energy of a thin, dense, cylindrically convergent gas shell, or into a small-diameter, high-ν/γ relativistic electron burst and oppositely directed ion burst. The kinetic energy of the fast ions and electrons can exceed the applied voltage by a factor of greater than 100. The different modes of energy concentration by the plasma focus are presented and discussed both in terms of their role in the direct yield of the focus and for the case of a plasma focus supplemented by various fusionable targets

  11. What is the Plasma Focus Thermonuclear Pulsors Technology?

    International Nuclear Information System (INIS)

    Ramos, R.; Gonzalez, J.; Moreno, C.; Clausse, A.

    2003-01-01

    In this paper we describe a type of neutron generators, called Plasma Focus, which is suitable to several applications, where traditional generators are non-applicable.The main characteristics are its transportability and to be non-contaminating, which would allow in-situ tests.The Plasma Focus, produces neutron pulses by thermonuclear fusion reactions, satisfy these requirements and it is comparatively non expensive.This last feature would assure competitivity in the neutron sources market

  12. Dense plasma focus - a literature review

    International Nuclear Information System (INIS)

    Tendys, J.

    1976-01-01

    The dense plasma focus (DPF) is a convenient source of short, intense neutron pulses, and dense, high temperature plasma. This review of the literature on the DPF indicates that its operation is still not understood, and attempts to show where the present data is either inadequate or inconsistent. Because the plasma conditions and neutron and x-ray fluxes vary from shot to shot, it is maintained that, to resolve inconsistencies in the present data, spectra need to be measured with energy and time resolution simultaneously, and cannot be built up from a large number of shots. Time resolutions of the order of 1 nsec for pulse lengths of about 100 nsec make these requirements especially difficult. Some theoretical models are presented for the neutron output and its spectrum, but no self-consistent description of the plasma in the focus region is likely for some time. (author)

  13. Computational numerical modelling of plasma focus

    International Nuclear Information System (INIS)

    Brollo, Fabricio

    2005-01-01

    Several models for calculation of the dynamics of Plasma Focus have been developed. All of them begin from the same physic principle: the current sheet run down the anode length, ionizing and collecting the gas that finds in its way.This is known as snow-plow model.Concerning pinch's compression, a MHD model is proposed.The plasma is treated as a fluid , particularly as a high ionized gas.However, there are not many models that, taking into account thermal equilibrium inside the plasma, make approximated calculations of the maximum temperatures reached in the pinch.Besides, there are no models which use those temperatures to estimate the termofusion neutron yield for the Deuterium or Deuterium-Tritium gas filled cases.In the PLADEMA network (Dense Magnetized Plasmas) a code was developed with the objective of describe the plasma focus dynamics, in a conceptual engineering stage.The codes calculates the principal variables (currents, time to focus, etc) and estimates the neutron yield in Deuterium-filled plasma focus devices.It can be affirmed that the code's experimental validation, in its axial and radial stages, was very successfully. However, it was accepted that the compression stage should be formulated again, to find a solution for a large variation of a parameter related with velocity profiles for the particles trapped inside the pinch.The objectives of this work can be stated in the next way : - Check the compression's model hypothesis. Develop a new model .- Implement the new model in the code. Compare results against experimental data of Plasma Focus devices from all around the world [es

  14. Preliminary studies on a plasma focus opening switch

    Energy Technology Data Exchange (ETDEWEB)

    Wong, C S; Moo, S P; Singh, J P [Univ. of Malaya, Kuala Lumpur (Malaysia). Physics Dept., Plasma Research Laboratory; Choi, P [Ecole Polytechnique, Palaiseau (France). Laboratoire de Physique des Milieux Ionises

    1997-12-31

    The small plasma focus device UNU/ICTP PFF has been modified to assess the operation of a plasma focus based long conduction (> 2 {mu}s) opening switch, with a plasma filled diode as the load. The UNU/ICTP PFF is a Mather type plasma focus device powered by a single 15 kV, 30 {mu}F capacitor delivering a peak current of 150 kA when discharged at 15 kV. The device has been optimized for reproducible focusing in various gases including deuterium, argon, carbon dioxide, helium as well as in air. In particular, the optimum operating pressure for air is between 0.5 to 1.1 mbar, whereas for argon it is between 0.3 to 3 mbar. For the operation of the UNU/ICTP PFF as an opening switch, the electrode geometry is modified to redirect the plasma motion at the end of the axial rundown phase to avoid the normal plasma focus action, and the operating regime is shifted to low pressure to favour plasma opening switch action. With air as the working gas, pressure as low as 10{sup -3} mbar was tested. At such a low pressure, a set of 12 plasma injection cable guns is used to initiate breakdown of the discharge. The design and operating principle is presented and some preliminary results obtained on the operational characteristics of this device are discussed. (author). 5 figs., 4 refs.

  15. Non-hydrodynamic model of plasma focus structure

    International Nuclear Information System (INIS)

    Imshennik, V.S.; Zueva, N.M.; Lokutsievskij, O.V.; Mikhajlova, M.S.

    1985-01-01

    Experimental and theoretical plasma focus study has resulted in the necessity of creating a non-hydrodynamic plasma focus structure model (MKHD model). This model describes the final stage of plasma focus, which starts immediately after maximum plasma compression. It is related to a very limited space near the neck of the sausage instability. The MKHD model is two-dimensional, axially symmetric and collisionless with respect to the ions and magnetohydrodynamic with respect to the electrons; it accounts for the pinch instability of the sausage type (m=0 mode). The MKHD model, first of all, explains the long time of the plasma focus existence and non-thermonuclear peculiarities in the neutron yield. The initial and boundary conditions are formulated in accordance with the experiments and the results of computations in the 2D MHD model. A non-stationary process of plasma focus dynamics is studied numerically for a relatively long time - about 20 ns; this time is, in principle, not restricted. The computations show that the external edge of the neck expands rather slowly (at a speed that is lower than the thermal ion velocity, by an order of magnitude), and the magnetic field energy is converted to the kinetic energy of the chaotic ion motion (which is doubled for the time of computation). A 'supra-thermal' tail (with the deuterium ion energy higher than 10 keV) forms slowly at the ion distribution function; this tail determines a substantial part of the total neutron yield. The formation of stable vortices, which actually determine the structure of the plasma flow during the developed non-hydrodynamic stage of the plasma focus, is also found in the computations. These properties of the development of the sausage instability, as found in the numerical experiment with the MKHD plasma focus model, are in qualitative agreement with the behaviour of an instability of the same type in the MHD models of the Z-pinch

  16. The plasma focus - numerical experiments leading technology

    International Nuclear Information System (INIS)

    Saw, S.H.; Lee, S.

    2013-01-01

    Numerical experiments on the plasma focus are now used routinely to assist design and provide reference points for diagnostics. More importantly guidance has been given regarding the implementation of technology for new generations of plasma focus devices. For example intensive series of experiments have shown that it is of no use to reduce static bank inductance L0 below certain values because of the consistent loading effects of the plasma focus dynamics on the capacitor bank. Thus whilst it was thought that the PF1000 could receive major benefits by reducing its bank inductance L 0 , numerical experiments have shown to the contrary that its present L 0 of 30 nH is already optimum and that reducing L 0 would be a very expensive fruitless exercise. This knowledge gained from numerical experiments now acts as a general valuable guideline to all high performance (ie low inductance) plasma focus devices not to unnecessarily attempt to further lower the static inductance L 0 . The numerical experiments also show that the deterioration of the yield scaling law (e.g. the fusion neutron yield scaling with storage energy) is inevitable again due to the consistent loading effect of the plasma focus, which becomes more and more dominant as capacitor bank impedance reduces with increasing capacitance C 0 as storage energy is increased. This line of thinking has led to the suggestion of using higher voltages (as an alternative to increasing C 0 ) and to seeding of Deuterium with noble gases in order to enhance compression through thermodynamic mechanisms and through radiation cooling effects of strong line radiation. Circuit manipulation e.g. to enhance focus pinch compression by current-stepping is also being numerically experimented upon. Ultimately however systems have to be built, guided by numerical experiments, so that the predicted technology may be proven and realized. (author)

  17. Magnetized whirls in plasma focus discharges

    International Nuclear Information System (INIS)

    Witalis, E.

    1979-05-01

    The plasma focus is briefly described with emphasis on its capabilities as a neutron source. The filamentary whirl structures observed in the discharge plasma are described. Starting with a simple, early and particularly well established case of vorticity imparted by a rotational electric field to the plasma in MHD generators, a general derivation is then outlined proving that such magnetically induced rotation is a general feature for the normally Hall-conducting magnetized plasma. Physical interpretations of the effect are given and objections to it are critically reviewed as is also a theory proposing radiation cooling as the cause of plasma filamentation. A more detailed derivation based essentially on the consistent description of the motion and the field generation of the charged plasma particles yields a theoretical model where the specific features of magnetically compressed plasmas are found. In particular, the ion collisionless skin depth is obtained as the key length parameter. This length is identified as roughly the whirl radius. In conjunction with a generalized Bennett relation theoretical whirl properties are predicted and found to agree with observations. Mechanisms that relate the whirls to nuclear fusion reaction conditions are tentatively indicated. (author)

  18. Compression Models for Plasma Focus Devices

    International Nuclear Information System (INIS)

    Gonzalez, Jose; Calusse, Alejandro; Ramos, Ruben; Rodriguez Palomino, Luis

    2003-01-01

    Using a numerical model that calculates the dynamics of Plasma Focus devices, we compared the results of three different compression models of the plasma pinch.One of the main objectives in this area is to develop a simplified model to calculate the neutron production of Plasma Focus devices, to study the influence of the main parameters in this neutron yield.The dynamics is thoroughly studied, and the model predicts fairly well values such as maximum currents and times for pinch collapse.Therefore, we evaluate here different models of pinch compression, to try to predict the neutron production with good agreement with the rest of the variables involved.To fulfill this requirement, we have experimental results of neutron production as a function of deuterium filling pressure in the chamber, and typical values of other main variables in the dynamics of the current sheet

  19. Beam acceleration in plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Antanasijevic, R.; Banjanac, R.; Dragic, A.; Maric, Z.; Stanojevic, J.; Udovicic, V. E-mail: udovicic@atom.phy.bg.ac.yu; Vukovic, J

    2001-06-01

    The proton beam emission from the small 8 kJ plasma focus device operated with the H{sub 2} filling was analyzed. Maximum energy and yield were obtained using NTD. The fast protons were registered with the energy up to 500 keV using the polycarbonate absorbers with the different thickness.

  20. Beam acceleration in plasma focus device

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Banjanac, R.; Dragic, A.; Maric, Z.; Stanojevic, J.; Udovicic, V.; Vukovic, J.

    2001-01-01

    The proton beam emission from the small 8 kJ plasma focus device operated with the H 2 filling was analyzed. Maximum energy and yield were obtained using NTD. The fast protons were registered with the energy up to 500 keV using the polycarbonate absorbers with the different thickness

  1. Experimental study of X-ray emission yield in a Filippov-type Plasma Focus operating in neon and neon-krypton mixture

    International Nuclear Information System (INIS)

    Babazadeh, A.R.; Kiai, S.M.S.; Roshan, M.V.; Emami, M.

    2002-01-01

    Since the installation of PF-DENA at AEOI about one year ago, we performed quantitative studies of variation of X-ray radiations from a new Filippov-type plasma focus device: Dena (90 kJ, 25 kV, 288 μF). The operating gas was neon at a constant pressure of 1 torr and different pressures of krypton admixture (up to 0.3 torr), with the discharge voltage up to 18 kV. For charging voltage of 17 kV with 41 kJ stored energy and spark gap pressure of 1.2x 10 -2 torr, the maximum soft and little hard X-ray (SXR-HXR) emission is found for the neon, resulting in a total SXR yield of 2 V/shot measured by silicon semiconductor diode detectors. Concerning the effect of krypton admixture, a maximum intensity of SXR radiation has been observed at low krypton pressure that is about 1 V/shot. At higher pressure, the quality of SXR emission decreases down to zero. However, the maximum intensity of the HXR radiation yield in the same pressure range was found to be 2.5 V/shot. By increasing the pressure of krypton up tp 0.3 torr, the results show that the krypton admixture gas generally causes, a decrease of the SXR radiation yield down to zero, whereas, the HXR emission yield carries a maximum value at the optimum pressure of krypton that is about 0.1 torr. Nevertheless, the pressure increments of krypton lead to decreasing in the discharge voltage for the maximum X-ray production. (author)

  2. Ion Distribution Measurement In Plasma Focus

    International Nuclear Information System (INIS)

    Suryadi; Sunardi; Usada, Widdi; Purwadi, Agus; Zaenuri, Akhmad

    1996-01-01

    Measurement of the Argon ion distribution in plasma focus by using Faraday cup has been done. The intensity of ion beam followed the I Rn rule, n=1,02. In the operation condition of 0,8 mbar and 12,5 kV the current sheath spen 2.2 to 2.4 μsecond in the rundown phase. Cu ion was also been observed in the Faraday cup

  3. Preliminary results of neutron production in Sahand plasma focus device

    International Nuclear Information System (INIS)

    Siahpoush, V.; Mohammadi, M.A.; Khorram, S.; Shabani, I.; Borhanian, J.; Ashrafi, S.; Naghshara, H.; Moslehi-Fard, M.; Sobhanian, S.

    2004-01-01

    We report in this paper the preliminary results of neutron generation during fusion reaction in deuterium in the Sahand Filipov type plasma focus, recently installed and put in operation at Tabriz University. The special calibration procedure for neutron detection system, using activation method is described

  4. Properties of the Dense Plasma Produced in Plasma Focus

    International Nuclear Information System (INIS)

    Peacock, N.J.; Wilcock, P.D.; Speer, R.J.; Morgan, P.D.

    1969-01-01

    The plasma produced by the focus or quasi-cylindrical magnetic compression which occurs at the open end of a metal-walled, coaxial plasma gun has been studied, using the electrical waveforms and the electromagnetic and reaction particle, emission. The electromagnetic radiation in the XUV region of the spectrum has previously been briefly reported, and the present paper describes further more detailed analyses of the line emission at wavelengths shorter than 10 Å when impurities are added to the gas filling. The emission is characteristic of a plasma with a temperature of a few keV and a density greater than 10 19 cm -3 , while the appearance of optical transitions in highly stripped ions, e. g. A XVIII, gives a measure of the thermalization in the plasma. The stored electrical energy has been doubled and the scaling of the neutron emission with the applied voltage and the initial particle density is presented. The duration of the neutron and X-ray emission is considerably longer than the observed instability growth time in the plasma filament. Calculations of the mode of heating and the confinement of the plasma are compared with experimental observations. (author)

  5. Plasma vitamin D and osteo-cartilaginous markers in Italian males affected by intervertebral disc degeneration: Focus on seasonal and pathological trend of type II collagen degradation.

    Science.gov (United States)

    Brayda-Bruno, Marco; Viganò, Marco; Cauci, Sabina; Vitale, Jacopo A; de Girolamo, Laura; De Luca, Paola; Lombardi, Giovanni; Banfi, Giuseppe; Colombini, Alessandra

    2017-08-01

    To evaluate plasma vitamin D and cross-linked C-telopeptides of type I (CTx-I) and type II (CTx-II) collagen concentrations in males with lumbar intervertebral disc degeneration (IVD) compared to healthy controls. Improved knowledge might suggest to optimize the vitamin D status of IVD patients and contribute to clarify mechanisms of cartilage degradation. 79 Italian males with lumbar IVD assessed by Magnetic Resonance Imaging (MRI) and 79 age, sex and BMI-matched healthy controls were enrolled. Plasma 25hydroxyvitamin D (25(OH)D), CTx-I and CTx-II were measured by immunoassays. Circannual seasonality, correlation between biomarkers concentrations and clinical variables were assessed. Overall subjects 25(OH)D and CTx-II showed month rhythmicity with acrophase in August/September and October/November, and nadir in February/March and April/May, respectively. An inverse correlation between 25(OH)D and CTx-I, and a direct correlation between CTx-II and CTx-I were observed. IVD patients, particularly with osteochondrosis, showed higher CTx-II than healthy controls. Month of sampling may affect plasma 25(OH)D and CTx-II concentrations. The correlation between CTx-I and CTx-II suggests an interplay between the osteo-cartilaginous endplate and the fibro-cartilaginous disc. The results of this study highlighted that osteochondrosis associates with increased cartilaginous catabolism. Vitamin D supplementation seems more necessary in winter for lumbar IVD patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Bursting of filaments in the plasma focus

    International Nuclear Information System (INIS)

    Gratton, F.T.L.

    1976-01-01

    Photographs of the current sheath of (low energy) plasma focus show a disruption of the filaments. This phenomenon is interpreted as a vortex breakdown. Physical parameters which support this hypothesis are obtained from measurements, from the theoretical thickness of the current sheath given by Nardi and from some models of the plasma flow. The widening of a vortex due to axial velocity increase is analyzed by means of magnetohydrodynamic collinear models. The main results are: (1) the existence of a limit separating supercritical from subcritical regimes (their character changes with the ratio between kinetic and magnetic energy); (2) the existence of flow regimes where the vortex radius remains approximately constant for moderate increments of the external velocity; (3) the structure of the vortex may change substantially for a sufficiently large increment of the external velocity, even in subcritical states; (4) the possibility that a burst of the vortex may occur when the external velocity suffers a slowdown

  7. Electron density measurements on the plasma focus

    International Nuclear Information System (INIS)

    Rueckle, B.

    1976-01-01

    The paper presents a determination of the maximum electron density in a plasma focus, produced with the NESSI experimental setup, by the method of laser beam deflection. For each discharge a time-resolved measurement was performed at four different places. Neutron efficiency as well as the time of the initial X-ray emission was registrated. The principle and the economic aspects of the beam deflection method are presented in detail. The experimental findings and the resulting knowledge of the neutron efficiency are discussed. (GG) [de

  8. Plasma devices for focusing extreme light pulses

    International Nuclear Information System (INIS)

    Fuchs, J.; Gonoskov, A.A.; Nakatsutsumi, M.; Nazarov, W.; Quere, F.; Sergeev, A.M.; Yan, X.Q.

    2014-01-01

    Since the inception of the laser, there has been a constant push toward increasing the laser peak intensity, as this has lead to opening the exploration of new territories, and the production of compact sources of particles and radiation with unprecedented characteristics. However, increasing the peak laser intensity is usually performed by enhancing the produced laser properties, either by lowering its duration or increasing its energy, which involves a great level of complexity for the laser chain, or comes at great cost. Focusing tightly is another possibility to increase the laser intensity, but this comes at the risk of damaging the optics with target debris, as it requires their placement in close proximity to the interaction region. Plasma devices are an attractive, compact alternative to tightly focus extreme light pulses and further increase the final laser intensity. (authors)

  9. Deposition of aluminium nanoparticles using dense plasma focus device

    International Nuclear Information System (INIS)

    Devi, Naorem Bilasini; Srivastava, M P; Roy, Savita

    2010-01-01

    Plasma route to nanofabrication has drawn much attention recently. The dense plasma focus (DPF) device is used for depositing aluminium nanoparticles on n-type Si (111) wafer. The plasma chamber is filled with argon gas and evacuated at a pressure of 80 Pa. The substrate is placed at distances 4.0 cm, 5.0 cm and 6.0 cm from the top of the central anode. The aluminium is deposited on Si wafer at room temperature with two focused DPF shots. The deposits on the substrate are examined for their morphological properties using atomic force microscopy (AFM). The AFM images have shown the formation of aluminium nanoparticles. From the AFM images, it is found that the size of aluminium nanoparticles increases with increase in distance between the top of anode and the substrate for same number of DPF shots.

  10. Current scaling of plasma focus devices

    International Nuclear Information System (INIS)

    Schiuma, C.; Herold, H.; Kaeppeler, H.J.; Shakhatre, M.; Auluck, S.K.H.

    1990-03-01

    In continuation of the work by G. Decker et al. on current and neutron yield scaling of plasma focus devices an analytical solution for the circuit equation (with resistance R = 0) in the compression phase was derived. Together with the solution for the rundown phase from G. Decker et al, which was extended for finite resistance (R ≠ 0), there follows an analytical scaling theory for maximum and pinch currents. At the same time there exists the possibility to discuss the influence of finite resistance on current variation and scaling parameters. The model solutions were checked out by numerical integrations of the current equation. While at the beginning of the rundown phase the ohmic resistance cannot be neglected (the magnitude R/L plays an important role), its influence at the end of the rundown phase and in the compression phase is negligible. The theoretically determined values are compared with the results of numerous probe measurements. (orig.)

  11. Ion acceleration in the plasma focus

    International Nuclear Information System (INIS)

    Deutsch, R.

    1982-09-01

    Experimental informations are used to estimate the time dependence of the current density in the plasma focus and the electromagnetic field is determined from the Maxwell equations. The acceleration of the ions in these fields is studied. A detailed analysis of the acceleration in the compression phase, in the expansion phase and during the evolution of the m=O instability is made. It is shown, that the appearance of fast selffocused quasineutral electron beams, as a result of the betatron acceleration, has a decisive importance in the ion acceleration during the m=O constriction. Models for electromagnetic ion acceleration are described for each phase. A concordance with many experimental results can be observed. (orig.)

  12. Deterministic dynamics of plasma focus discharges

    International Nuclear Information System (INIS)

    Gratton, J.; Alabraba, M.A.; Warmate, A.G.; Giudice, G.

    1992-04-01

    The performance (neutron yield, X-ray production, etc.) of plasma focus discharges fluctuates strongly in series performed with fixed experimental conditions. Previous work suggests that these fluctuations are due to a deterministic ''internal'' dynamics involving degrees of freedom not controlled by the operator, possibly related to adsorption and desorption of impurities from the electrodes. According to these dynamics the yield of a discharge depends on the outcome of the previous ones. We study 8 series of discharges in three different facilities, with various electrode materials and operating conditions. More evidence of a deterministic internal dynamics is found. The fluctuation pattern depends on the electrode materials and other characteristics of the experiment. A heuristic mathematical model that describes adsorption and desorption of impurities from the electrodes and their consequences on the yield is presented. The model predicts steady yield or periodic and chaotic fluctuations, depending on parameters related to the experimental conditions. (author). 27 refs, 7 figs, 4 tabs

  13. Delayed hot spots in a low energy plasma focus

    International Nuclear Information System (INIS)

    Rout, R.K.; Shyam, A.

    1991-01-01

    In a low energy Mather-type plasma focus device, hot spots having temperature in the range of few keV have been observed even 1 μs after the pinch disintegration and in regions away from the pinch area. These hot spots are perhaps created by the thermal runaway due to temperature fluctuations in the background gas. (author). 12 refs., 6 figs

  14. Plasma-current structures of plasma focus during the current disruption

    International Nuclear Information System (INIS)

    Krokhin, O.N.; Kalachev, N.V.; Malafeev, Yu.S.; Nikulin, V.Ya; Polukhin, S.N.; Tsybenko, S.P.

    2000-01-01

    The results are presented of an investigation of the plasma structures arising during the current disruption in the Dense Plasma Focus (DPF). The study was performed using the laser-shadow and interferometry methods together with measurements of current and X-ray radiation. An analysis of the experimental results shows that for the construction of a multi mega-amperes current disruption device, the Filippov type of DPF (in comparison with the Mather type) is to be preferred since the processes occurring in the X-ray regime are much faster than in the pinch regime, and this type of plasma focus is geometrically more suitable for the assembly of such a current disrupter.This disrupter is now under construction, based on the 'Tulip' DPF installation

  15. Design and preliminary results of the IMA plasma focus experiment

    Energy Technology Data Exchange (ETDEWEB)

    Soliman, H M; Masoud, M M [Arab Republic of Egypt, Atomic Energy Authority Plasma physics and Nuclear Fusion department, Cairo (Egypt)

    1994-12-31

    The present paper describes the design, operation and characteristics of aton 1MA plasma focus device, which built in egypt at the plasma physics department, N.R.C., atomic energy authority. The main parts of the system are: the coaxial electrodes of mather type, the expansion chamber, the condenser bank of 75 kJ stored energy, the pressurized spark gap switches and Blumlein trigger system. Measurement of the breakdown voltage between plasma focus electrodes and discharge current, using half of the condenser bank, showed that, for U{sub c} h = 32 kV, the discharge current was 0.5 Ma. In the discharge current and voltage traces a sharp drop in discharge current correspondingly to a sudden rise in voltage have been observed, which characterize the focus regime. Time structure of the x-ray emission measurements have been performed by means of scintillation detectors. by using a hydrogen gas the results showed that, the x-ray intensity is increased with increasing the hydrogen gas pressure. plasma sheath current density, J-Z distribution in axial direction during the acceleration phase of the discharge is studied, using a miniature Rogovsky coil. The results cleared that J{sub z} is increased with the axial distance from breech to muzzle at different hydrogen gas pressures. 12 figs.

  16. Design and preliminary results of the IMA plasma focus experiment

    International Nuclear Information System (INIS)

    Soliman, H.M.; Masoud, M.M.

    1993-01-01

    The present paper describes the design, operation and characteristics of aton 1MA plasma focus device, which built in egypt at the plasma physics department, N.R.C., atomic energy authority. The main parts of the system are: the coaxial electrodes of mather type, the expansion chamber, the condenser bank of 75 kJ stored energy, the pressurized spark gap switches and Blumlein trigger system. Measurement of the breakdown voltage between plasma focus electrodes and discharge current, using half of the condenser bank, showed that, for U c h = 32 kV, the discharge current was 0.5 Ma. In the discharge current and voltage traces a sharp drop in discharge current correspondingly to a sudden rise in voltage have been observed, which characterize the focus regime. Time structure of the x-ray emission measurements have been performed by means of scintillation detectors. by using a hydrogen gas the results showed that, the x-ray intensity is increased with increasing the hydrogen gas pressure. plasma sheath current density, J-Z distribution in axial direction during the acceleration phase of the discharge is studied, using a miniature Rogovsky coil. The results cleared that J z is increased with the axial distance from breech to muzzle at different hydrogen gas pressures. 12 figs

  17. Plasma focus - dense Z pinch and their applications

    International Nuclear Information System (INIS)

    Ishii, Shozo

    1986-02-01

    ''Workshop on the possibility of Z-pinch as a intense pulse light source'' in 1983 and ''Research meeting on plasma focus and Z-pinch'' in 1984 were held at Institute of Plasma Physics, Nagoya University under a collaborating research program. Research activities reported at the meetings on plasma focus, dense Z-pinch, and related phenomena are summerized. (author)

  18. Recent results on medium-size plasma-focus device

    International Nuclear Information System (INIS)

    Miklaszewski, R.; Kasperczuk, A.; Paduch, M.; Tomaszewaski, K.; Wereszczynski, Z.

    1992-01-01

    A brief history of investigation carried out on the PF-150 plasma-focus device is presented. Essential results concerning the dynamics of plasma sheath are summarized. The present state of investigation and main areas of interest are shown. (author)

  19. Laser plasma focus produced in a ring target

    International Nuclear Information System (INIS)

    Saint-Hilaire, G.; Szili, Z.

    1976-01-01

    A new geometry for generating a laser-produced plasma is presented. A toroidal mirror is used to focus a CO 2 laser beam on the inside wall of a copper ring target. The plasma produced converges at the center of the ring where an axial plasma focus is formed. High-speed photography shows details of a plasma generated at a distance from the target surface. This new geometry could have important applications in the field of x-ray lasers

  20. Self-focusing of laser beam crossing a laser plasma

    International Nuclear Information System (INIS)

    Bakos, J.S.; Foeldes, I.B.; Ignacz, P.N.; Soerlei, Zs.

    1983-03-01

    A crossed-beam experiment was performed to clarify the mechanism of self-focusing in a laser produced spark. The plasma was created by one beam and self-focusing was observed in the weak probe beam which crossed the plasma. Experimental results show that the cause of self-focusing is the nonuniform heating mechanism. (author)

  1. Similitude observations and scaling laws for the plasma focus

    International Nuclear Information System (INIS)

    Kaeppeler, H.J.

    It has been attempted to give a coherent explanation of the most important physical processes concerning a model theory of the plasma focus of the Mather type. For this purpose the compression process, the stable dense phase and the subsequent neutron-producing instable phase were described. With the assumption that I 0 2 /rho 0 R 0 2 = const and t 0 /t/sub c/ = const a theoretical explanation is given for the already experimentally determined dependence of the neutron production on the fourth power of the maximum current. A few other conclusions based on these scaling laws are being discussed

  2. Plasma lenses for SLAC Final Focus Test facility

    International Nuclear Information System (INIS)

    Betz, D.; Cline, D.; Joshi, C.; Rajagopalan, S.; Rosenzweig, J.; Su, J.J.; Williams, R.; Chen, P.; Gundersen, M.; Katsouleas, T.; Norem, J.

    1991-01-01

    A collaborative group of accelerator and plasma physicists and engineers has formed with an interest in exploring the use of plasma lenses to meet the needs of future colliders. Analytic and computational models of plasma lenses are briefly reviewed and several design examples for the SLAC Final Focus Test Beam are presented. The examples include discrete, thick, and adiabatic lenses. A potential plasma source with desirable lens characteristics is presented

  3. Dense Plasma Focus - From Alternative Fusion Source to Versatile High Energy Density Plasma Source for Plasma Nanotechnology

    Science.gov (United States)

    Rawat, R. S.

    2015-03-01

    The dense plasma focus (DPF), a coaxial plasma gun, utilizes pulsed high current electrical discharge to heat and compress the plasma to very high density and temperature with energy densities in the range of 1-10 × 1010 J/m3. The DPF device has always been in the company of several alternative magnetic fusion devices as it produces intense fusion neutrons. Several experiments conducted on many different DPF devices ranging over several order of storage energy have demonstrated that at higher storage energy the neutron production does not follow I4 scaling laws and deteriorate significantly raising concern about the device's capability and relevance for fusion energy. On the other hand, the high energy density pinch plasma in DPF device makes it a multiple radiation source of ions, electron, soft and hard x-rays, and neutrons, making it useful for several applications in many different fields such as lithography, radiography, imaging, activation analysis, radioisotopes production etc. Being a source of hot dense plasma, strong shockwave, intense energetic beams and radiation, etc, the DPF device, additionally, shows tremendous potential for applications in plasma nanoscience and plasma nanotechnology. In the present paper, the key features of plasma focus device are critically discussed to understand the novelties and opportunities that this device offers in processing and synthesis of nanophase materials using, both, the top-down and bottom-up approach. The results of recent key experimental investigations performed on (i) the processing and modification of bulk target substrates for phase change, surface reconstruction and nanostructurization, (ii) the nanostructurization of PLD grown magnetic thin films, and (iii) direct synthesis of nanostructured (nanowire, nanosheets and nanoflowers) materials using anode target material ablation, ablated plasma and background reactive gas based synthesis and purely gas phase synthesis of various different types of

  4. Dense Plasma Focus - From Alternative Fusion Source to Versatile High Energy Density Plasma Source for Plasma Nanotechnology

    International Nuclear Information System (INIS)

    Rawat, R S

    2015-01-01

    The dense plasma focus (DPF), a coaxial plasma gun, utilizes pulsed high current electrical discharge to heat and compress the plasma to very high density and temperature with energy densities in the range of 1-10 × 10 10 J/m 3 . The DPF device has always been in the company of several alternative magnetic fusion devices as it produces intense fusion neutrons. Several experiments conducted on many different DPF devices ranging over several order of storage energy have demonstrated that at higher storage energy the neutron production does not follow I 4 scaling laws and deteriorate significantly raising concern about the device's capability and relevance for fusion energy. On the other hand, the high energy density pinch plasma in DPF device makes it a multiple radiation source of ions, electron, soft and hard x-rays, and neutrons, making it useful for several applications in many different fields such as lithography, radiography, imaging, activation analysis, radioisotopes production etc. Being a source of hot dense plasma, strong shockwave, intense energetic beams and radiation, etc, the DPF device, additionally, shows tremendous potential for applications in plasma nanoscience and plasma nanotechnology. In the present paper, the key features of plasma focus device are critically discussed to understand the novelties and opportunities that this device offers in processing and synthesis of nanophase materials using, both, the top-down and bottom-up approach. The results of recent key experimental investigations performed on (i) the processing and modification of bulk target substrates for phase change, surface reconstruction and nanostructurization, (ii) the nanostructurization of PLD grown magnetic thin films, and (iii) direct synthesis of nanostructured (nanowire, nanosheets and nanoflowers) materials using anode target material ablation, ablated plasma and background reactive gas based synthesis and purely gas phase synthesis of various different types of

  5. Preliminary Results Of A 600 Joules Small Plasma Focus Device

    International Nuclear Information System (INIS)

    Lee, S. H.; Yap, S. L.; Wong, C. S.

    2009-01-01

    Preliminary results of a 600 J (3.7 μF, 18 kV) Mather type plasma focus device operated at low pressure will be presented. The discharge is formed between a solid anode with length of 6 cm and six symmetrically and coaxially arranged cathode rods of same lengths. The cathode base is profiled in a knife-edge design and a set of coaxial plasma gun are attached to it in order to initiate the breakdown and enhance the current sheath formation. The experiments have been performed in argon gas under a low pressure condition of several microbars. The discharge current and the voltage across the electrodes during the discharge are measured with high voltage probe and current coil. The current and voltage characteristics are used to determine the possible range of operating pressure that gives good focusing action. At a narrow pressure regime of 9.0±0.5 μbar, focusing action is observed with good reproducibility. Preliminary result of ion beam energy is presented. More work will be carried out to investigate the radiation output.

  6. Plasma waves generated by rippled magnetically focused electron beams surrounded by tenuous plasmas

    International Nuclear Information System (INIS)

    Cuperman, S.; Petran, F.

    1982-01-01

    This chapter investigates the electrostatic instability and the corresponding unstable wave spectrum of magnetically focused neutralized rippled electron beams under spacelike conditions. Topics considered include general equations and equilibrium, the derivation of the dispersion relation, and the solution of the dispersion relation (long wavelength perturbations, short wavelength perturbations, the rippled beam). The results indicate that in the long wavelength limit two types of instability (extending over different frequency ranges) exist. An instability of the beam-plasma type occurs due to the interaction between the beam electrons and the surrounding plasm electrons at the beam-plasma interface. A parametric type instability is produced by the coupling of a fast forward wave and a fast backward wave due to the rippling (modulation) of the beam. It is demonstrated that in the short wavelength limit, surface waves which are stable for the laminar beam may become unstable in the rippled beam case

  7. Three-fluid magnetohydrodynamical simulation of plasma focus discharges

    International Nuclear Information System (INIS)

    Behler, K.; Bruhns, H.

    1987-01-01

    A two-dimensional, three-fluid code based on the two-fluid Potter code [Methods in Computational Physics (Academic, New York, 1970), Vol. 9, p. 340] was developed for simulating the plasma focus discharge. With this code it is possible to treat the neutral gas in addition to the plasma components and to model the ionization and recombination phenomena. Thus the sheet dynamics in a plasma focus can be studied and effects investigated such as the occurrence of residual gas (or plasma) density behind the current sheet in the run-down phase. This is a prerequisite to the occurrence of leak currents, which are one of the causes limiting the performance of large plasma focus devices. It is shown that fast operating foci with small dimensions behave favorably compared with the ''classical'' Mather focus [Methods of Experimental Physics (Academic, New York, 1971), Vol. 9B, p. 187] with long coaxial electrodes

  8. Preliminary results obtained from a dense plasma focus

    International Nuclear Information System (INIS)

    Sinman, S.; Sinman, A.

    1982-01-01

    In this study, for the data processing in our Dense Plasma Focus (DPF) system, a multiparameters numerical hierarchy obtained from the fundamental equations based on the snowplows model and its conclusions have been developed. Evaluating the data along the transients of the total plasma current, the anode current and the focus voltage recorded by an oscilloscope, they have been possible to determine the time domain plasma parameters such as the shock thickness, the sheath temperature, velocity and electron density, the pressure at the focus phase and the plasma temperature. Besides, the dissipated energy through the focus notch or in other words, the plasma temperature has also been calculated by means of the numerical integration. In the text, a performance chart together with some other correlation curves for the optimization of the DPF systems are submitted and discussed. (author)

  9. Light ion beams generation in dense plasma focus

    International Nuclear Information System (INIS)

    Yokoyama, M.; Kitagawa, Y.; Yamada, Y.; Okada, M.; Yamamoto, Y.

    1982-01-01

    The high energy deuterons and protons in a Mather type plasma focus device were measured by nuclear activation techniques. The radioactivity induced in graphite, aluminum and copper targets provided the deuteron intensity, energy spectra and angular dependence. High energy protons were measured by cellulose nitrate particle track detectors. The plasma focus device was operated at 30 kV for a stored energy of 18 kJ at 1.5 Torr D 2 (low pressure mode), and 5 Torr D 2 (high pressure mode). The yield ratio of N-13 and Al-28 showed the mean deuteron energy of 1.55 MeV under low pressure mode and of 1.44 MeV under high pressure mode. The deuteron energy spectra were measured by the stacks of 10 aluminum foils, and consisted of two components as well as the proton energy spectra measured by CN film technique. The angular spread of deuteron beam was within 30 degree under low pressure mode. Under high pressure mode, the distribution showed multi-structure, and two peaks were observed at the angle smaller than 20 degree and at 60 degree. The protons with energy more than 770 keV were directed in the angle of 10 degree. The high energy electron beam was also observed. A three-channel ruby laser holographic interferometry was used to see the spatial and temporal location of the generation of high energy ions. The ion temperature in plasma focus was estimated from D + He 3 mixture gas experiment. (Kato, T.)

  10. Plasma focusing and diagnosis of high energy particle beams

    International Nuclear Information System (INIS)

    Chen, Pisin.

    1990-09-01

    Various novel concepts of focusing and diagnosis of high energy charged particle beams, based on the interaction between the relativistic particle beam and the plasma, are reviewed. This includes overdense thin plasma lenses, and (underdense) adiabatic plasma lens, and two beam size monitor concepts. In addition, we introduce another mechanism for measuring flat beams based on the impulse received by heavy ions in an underdense plasma. Theoretical investigations show promise of focusing and diagnosing beams down to sizes where conventional methods are not possible to provide. 21 refs

  11. Self-focusing of electron bunches in a nonlinear plasma

    International Nuclear Information System (INIS)

    Krasovitskii, V.B.; Osmolovsky, S.I.

    1994-01-01

    The phenomena of self-focusing of previously bunched electron beam in hot nonlinear plasma with the frequency which less than the plasma one is studied. It is established that influence of the Miller's force nonlinearity of the plasma don't leads to self-focusing breaking. However in the case of a dense beam, the appearance strong resonant electric field is followed by the change of the sign of the plasma dielectric constant to positive at the beam axis. But the dielectric constant remain negative at the outer of the beam

  12. Numerical experimentation on focusing time and neutron yield in GN1 plasma focus machine

    International Nuclear Information System (INIS)

    Singh, Arwinder; Lee, Sing; Saw, S.H.

    2014-01-01

    In this paper, we have shown how we have fitted Lee's six phase model code to analyze the current waveform of the GN1 plasma focus machine working in deuterium gas. The Lee's 6-phase model codes was later configured to work between 0.5 to 6 Torr and the results of both focusing time and neutron yield was then compared with the published experimental results. The final results indicate that Lee's code, gives realistic plasma dynamics and focus properties together with a realistic neutron yield for GN1 plasma focus, without the need of any adjustable parameters, needing only to fit the computed current trace to a measured current trace. (author)

  13. Laser light scatter experiments on plasma focus plant

    International Nuclear Information System (INIS)

    Wenzel, N.

    1985-01-01

    The plasma focus plant is an experiment on nuclear fusion, which is distinguished by a high neutron yield. Constituting an important method of diagnosis in plasma focussing, the laser light scatter method makes it possible, apart from finding the electron temperature and density, to determine the ion temperature resolved according to time and place and further, to study the occurrence of micro-turbulent effects. Starting from the theoretical basis, this dissertation describes light scatter measurements with ruby lasers on the POSEIDON plasma focus. They are given, together with earlier measurements on the Frascati 1 MJ plant and the Heidelberg 12 KJ plant. The development of the plasma parameters and the occurrence of superthermal light scatter events are discussed in connection with the dynamics of the plasma and the neutron emission characteristics of the individual plants. The results support the view that the thermo-nuclear neutron production at the plasma focus is negligible. Although the importance of micro-turbulent mechanisms in producing neutrons cannot be finally judged, important guidelines are given for the spatial and time relationships with plasma dynamics, plasma parameters and neutron emission. The work concludes with a comparison of all light scatter measurements at the plasma focus described in the literature. (orig.) [de

  14. Electrical characteristics of a small plasma focus device

    International Nuclear Information System (INIS)

    Choi, P.; Favre, M.; Silva, P.; Chuaqui, H.; Wyndham, E.

    1996-01-01

    Efficient plasma focus operation relies on uniform initial breakdown across the insulator surface. The basic plasma focus electric circuit is discussed in order to highlight circuit modifications that produce high voltage oscillation at the initial breakdown time. Superimposed on the main discharge voltage, such oscillating voltage has been found in real systems to enhance the initial gas breakdown by localizing the initial current path across the insulator surface. PSPICE circuit simulations are compared with electric signals from different operational plasma focus devices. (author). 3 figs., 7 refs

  15. Matching of dense plasma focus devices with fission reactors

    International Nuclear Information System (INIS)

    Harms, A.A.; Heindler, M.

    1978-01-01

    The potential role of dense plasma focus devices as compact neutron sources for fissile fuel breeding in conjunction with existing fission reactors is considered. It is found that advanced plasma focus devices can be used effectively in conjunction with neutronically efficient fission reactors to constitute ''self-sufficient'' breeders. Correlations among the various parameters such as the power output and conversion ratio of the fission reactor with the neutron yield and capacitor bank energy of the dense plasma focus device are presented and discussed

  16. Focusing of relativistic electron bunch, moving in cylindrical plasma waveguide

    International Nuclear Information System (INIS)

    Amatuni, A.Ts.; Ehlbakyan, S.S.; Sekhpossyan, E.V.

    1994-01-01

    The problem on the focusing of electron bunches moving with the relativistic velocity along the axis of cylindrical overdense plasma waveguide with the conducting internal surface is considered. The existence of periodic and nonperiodic components of the fields, generated in the plasma is shown. The conditions of electron bunch self-focusing by transverse electrical field and azimuthal magnetic field are derived. The possibility of the acceleration and focusing of electron or positron bunches by driving electron bunch wake field is discussed. The conditions, when the bunch in plasma waveguide moves without wake fields generating are obtained, which could be of the interest for the transport of relativistic electron (positron) bunches. 5 refs

  17. Self-organisation phenomena in the plasma focus

    International Nuclear Information System (INIS)

    Deutsch, R.; Grauf, W.; Herold, H.; Schmidt, H.

    1982-06-01

    The structure of the final minimum-energy state of the focus plasma was studied, using Taylor's relaxation theory. A superposition of the reversed pinch field and the field of eddies was obtained. Similar structures could be observed experimentally. (orig.)

  18. Numerical Study of Radiation Emissions from the Plasma Focus

    International Nuclear Information System (INIS)

    Akel, M.; Salo, S.

    2013-12-01

    Ion populations of studied plasma have been calculated versus electron temperatures. The expected emission spectra (full, Bremsstrahlung, recombination, and line) of plasma focus operated with different gases (nitrogen, oxygen, neon, argon, krypton and xenon) have been studied for different conditions using POPULATE, SPECTRA, XRAYFIL and FLYCHK codes for non-local thermodynamic equilibrium model (NLTE). The suitable electron temperatures ranges for soft X-ray and extreme ultraviolet (EUV) emissions from plasma focus have been investigated. The Ratio- BPX65.F code has been written in FORTRAN 77 for studying the soft X-ray emission of plasma focus using BPX65 PIN Diode X-ray Spectrometer technique. The X-ray ratio curves for various electron temperatures with probable electron and ion densities of the studied plasma produced have been computed with the assumption of non-LTE model for the distribution of the ionic species. The calculated X-ray ratio curves have been compared with experimental results for the argon plasma focus. These ratio curves could be used for electron temperatures deduction of plasma focus (author).

  19. Technical and experimental investigations of a plasma focus neutron source

    International Nuclear Information System (INIS)

    Rapp, H.K.

    The results obtained from two plasma-focus devices of different size allow to report on the technical and physical properties of such neutron flash sources. The results of some diagnostic methods used for the control of the gas discharge and for the measurement of the neutron production are included. The planning of plasma focus devices is illustrated with the aid of snow-plow calculations

  20. Self-focusing relativistic electron streams in plasmas

    International Nuclear Information System (INIS)

    Cox, J.L. Jr.

    1975-01-01

    A relativistic electron stream propagating through a dense plasma induces current and charge densities which determine how the stream can self-focus. Magnetic self-focusing is possible because stream-current neutralization, although extensive, is not complete. Electric self-focusing can occur because the stream charge becomes overneutralized when the net current is smaller than a critical value. Under some circumstances, the latter process can cause the stream to focus into a series of electron bunches

  1. Electrostatic plasma lens for focusing negatively charged particle beams.

    Science.gov (United States)

    Goncharov, A A; Dobrovolskiy, A M; Dunets, S M; Litovko, I V; Gushenets, V I; Oks, E M

    2012-02-01

    We describe the current status of ongoing research and development of the electrostatic plasma lens for focusing and manipulating intense negatively charged particle beams, electrons, and negative ions. The physical principle of this kind of plasma lens is based on magnetic isolation electrons providing creation of a dynamical positive space charge cloud in shortly restricted volume propagating beam. Here, the new results of experimental investigations and computer simulations of wide-aperture, intense electron beam focusing by plasma lens with positive space charge cloud produced due to the cylindrical anode layer accelerator creating a positive ion stream towards an axis system is presented.

  2. Experimental validation of models for Plasma Focus devices

    International Nuclear Information System (INIS)

    Rodriguez Palomino, Luis; Gonzalez, Jose; Clausse, Alejandro

    2003-01-01

    Plasma Focus(PF) Devices are thermonuclear pulsators that produce short pulsed radiation (X-ray, charged particles and neutrons). Since Filippov and Mather, investigations have been used to study plasma properties. Nowadays the interest about PF is focused in technology applications, related to the use of these devices as pulsed neutron sources. In the numerical calculus the Inter institutional PLADEMA (PLAsmas DEnsos MAgnetizados) network is developing three models. Each one is useful in different engineering stages of the Plasma Focus design. One of the main objectives in this work is a comparative study on the influence of the different parameters involved in each models. To validate these results, several experimental measurements under different geometry and initial conditions were performed. (author)

  3. Physics and technology of large plasma focus devices

    International Nuclear Information System (INIS)

    Herold, H.

    1990-01-01

    This paper reports on the plasma focus (PF) which produces a high temperature (0,5 to 1 keV), high density (5 · 10 18 cm -3 ), short living (up to 500 ns) fusion plasma in a very simple and cheap device. In the focus plasma, fusion processes take place with an energy efficiency which is not surpassed even by large Tokamak or Inertial Confinement Fusion devices. But this fusion efficiency and the high fusion neutron yield are not the only impetus to PF research. Due to the high energy density in the focus plasma (j ≥ 10 6 A/cm 2 exclamation point), many very interesting, mostly nonlinear phenomena take place which led to high intensity electron, ion and radiation emission. Micro- and macro instabilities, turbulence and selforganization processes develop. Most of these phenomena are not or only poorly understood

  4. Pulsed x-ray generation from a plasma focus device

    International Nuclear Information System (INIS)

    Zambra, M; Bruzzone, H; Sidelnikov, Y; Kies, W; Moreno, C; Sylvester, G; Silva, P; Moreno, J; Soto, L

    2003-01-01

    Dynamical pinches coupled to electrodes like the dense Z-pinch or the dense plasma focus have been intensively studied in the last four decades for their high fusion efficiency and their application potential. Though the expectations of the eighties of the last century, scaling these pinches up to fusion reactors, did not come true, the development of fast and powerful experiments resulted in new insights in pinch physics and paved the way for developing compact dynamical pinches as pulsed neutron and X-radiation sources for many applications. There is a permanent and growing interest in the research community for understanding and determining the generation properties of X-rays, neutrons and charged particles emitted from a high-temperature high-density plasmas, especially in the plasma focus configuration. The Plasma Physics and Plasma Technology Group of the CCHEN has developed the SPEED4 fast-plasma focus device, in collaboration with the Plasma Physics Group of the Dusseldorf University, in order to perform experimental studies such as X-ray and neutron emission, and electron and ion beam characterization (author)

  5. Parametric studies in a small plasma focus device

    International Nuclear Information System (INIS)

    Chuaqui, H.; Favre, M.; Silva, P.; Wyndham, E.

    1996-01-01

    Very high temperature and density plasmas can be produced in modest size plasma focus devices at the kJ level. Much of the scaling parameters on the plasma focus have been evaluated, though many questions still remain. The modest cost and simple construction allows easy modification to the device and the discharge parameters. In this paper the authors report on a small plasma focus device, which is set-up to investigate the effect of some of those modifications on the plasma, with detailed experimental diagnostics. Experiments have been carried out in various gases and with mixtures of different ratios. Extended operating range from below 0.5 torr upwards has been achieved with the implementation of the auxiliary discharge circuit. Despite the low voltage and low energy operation, energetic beam formation has been observed at the time of the final compression, prior to disruption. Current sheath formation and evolution has been characterized using the magnetic probes array, in correlation with beam formation and plasma emission. The relationship of the current sheath structure and that of the pinched plasma, as shown by the filtered X-ray pinhole camera, has been investigated

  6. Interaction of powerful hot plasma and fast ion streams with materials in dense plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Chernyshova, M., E-mail: maryna.chernyshova@ipplm.pl [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Gribkov, V.A. [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Institution of Russian Academy of Sciences A.A. Baikov Institute of Metallurgy and Material Science RAS, Moscow (Russian Federation); Kowalska-Strzeciwilk, E.; Kubkowska, M.; Miklaszewski, R.; Paduch, M.; Pisarczyk, T.; Zielinska, E. [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Demina, E.V.; Pimenov, V.N.; Maslyaev, S.A. [Institution of Russian Academy of Sciences A.A. Baikov Institute of Metallurgy and Material Science RAS, Moscow (Russian Federation); Bondarenko, G.G. [National Research University Higher School of Economics (HSE), Moscow (Russian Federation); Vilemova, M.; Matejicek, J. [Institute of Plasma Physics of the CAS, Prague (Czech Republic)

    2016-12-15

    Highlights: • Materials perspective for use in mainstream nuclear fusion facilities were studied. • Powerful streams of hot plasma and fast ions were used to induce irradiation. • High temporal, spatial, angular and spectral resolution available in experiments. • Results of irradiation were investigated by number of analysis techniques. - Abstract: A process of irradiating and ablating solid-state targets with hot plasma and fast ion streams in two Dense Plasma Focus (DPF) devices – PF-6 and PF-1000 was examined by applying a number of diagnostics of nanosecond time resolution. Materials perspective for use in chambers of the mainstream nuclear fusion facilities (mainly with inertial plasma confinement like NIF and Z-machine), intended both for the first wall and for constructions, have been irradiated in these simulators. Optical microscopy, SEM, Atomic Emission Spectroscopy, images in secondary electrons and in characteristic X-ray luminescence of different elements, and X-ray elemental analysis, gave results on damageability for a number of materials including low-activated ferritic and austenitic stainless steels, β-alloy of Ti, as well as two types of W and a composite on its base. With an increase of the number of shots irradiating the surface, its morphology changes from weakly pronounced wave-like structures or ridges to strongly developed ones. At later stages, due to the action of the secondary plasma produced near the target materials they melted, yielding both blisters and a fracturing pattern: first along the grain and then “in-between” the grains creating an intergranular net of microcracks. At the highest values of power flux densities multiple bubbles appeared. Furthermore, in this last case the cracks were developed because of microstresses at the solidification of melt. Presence of deuterium within the irradiated ferritic steel surface nanolayers is explained by capture of deuterons in lattice defects of the types of impurity atoms

  7. Study of opening switch characteristics of a plasma focus

    International Nuclear Information System (INIS)

    Rhee, M.J.; Schneider, R.F.

    1985-01-01

    It is shown that a current charged transmission line and an opening switch can be used as an inductive energy storage system to produce a high power pulse. A plasma focus device, in which a transmission line is inserted in series with the capacitor bank and a coaxial gun, is considered as an inductive energy storage system. The m = 0 instability in the plasma focus is utilized as an opening switch and the disrupted plasma column is considered as bipolar diode. The system is described preferably by the transmission line theory rather than the lumped circuit theory. The relationship between the output voltage and the current drop is given by V = ΔIZ, where Z is the characteristic impedance of the transmission line. The current drop ΔI depends on the mismatched load impedance of the plasma diode which is governed by nature of the m = 0 instability

  8. Conceptual Design and Simulation of a Miniature Plasma Focus

    International Nuclear Information System (INIS)

    Jafari, H.; Habibi, M.; Amrollahi, R.

    2012-01-01

    Design and construction of a miniature plasma focus device with 3.6 J of energy bank is reported. In design the device, some of very important parameters of designing such as plasma energy density and derive parameter was used. Regarding to the electrical and geometrical parameters of the device, a simulation is carried out by MATLAB software. Simulation results showed that the formation of the pinch have occurred at the moment of the peak discharge current.

  9. Paul Ion Trap as a Diagnostic for Plasma Focus

    Science.gov (United States)

    Sadat Kiai, S. M.; Adlparvar, S.; Zirak, A.; Alhooie, Samira; Elahi, M.; Sheibani, S.; Safarien, A.; Farhangi, S.; Dabirzadeh, A. A.; Khalaj, M. M.; Mahlooji, M. S.; KaKaei, S.; Talaei, A.; Kashani, A.; Tajik Ahmadi, H.; Zahedi, F.

    2010-02-01

    The plasma discharge contamination by high and low Z Impurities affect the rate of nuclear fusion reaction products, specially when light particles have to be confined. These impurities should be analyzed and can be fairly controlled. This paper reports on the development of a Paul ion trap with ion sources by impact electron ionization as a diagnostic for the 10 kJ Iranian sunshine plasma focus device. Preliminary results of the residual gas are analyzed and presented.

  10. Spheromak type plasma experiment apparatus

    International Nuclear Information System (INIS)

    Odagiri, Kiyoyuki; Miyauchi, Yasuyuki; Oomura, Hiroshi

    1985-01-01

    The fusion power reactor which is expected to be the most promising energy has been developed for several plasma confinement systems. Under these circumstances, Spheromak configuration has recently attracted attention because of its simple structure and efficient plasma confinement. This apparatus was ordered by the Engineering Department of University of Tokyo for basic studies of the Spheromak plasma confinement technologies. This forms Spheromak plasma according to the induction discharge system which injects this plasma with magnetic energy generated by a toroidal current in the plasma and discharges the current through the electrical feed through. Toroidal current is induced by the poloidal coil in the vessel. We worked together with the researchers of University of Tokyo to conduct experiments and confirmed the formation and confinement of Spheromak plasma in the initial test. (author)

  11. Stopping of magnetic collapse due to residual plasma effect in a plasma focus

    International Nuclear Information System (INIS)

    Sasorov, P.V.

    1990-01-01

    The effect of the external plasma of a divergent current shell of a plasma pinch is discussed. Even a small amount of plasma is shown to be sufficiently enough for principal change in dynamics of late stages of sausage-type instability development in a Z-pinch

  12. Lifetime and shelf life of sealed tritium-filled plasma focus chambers with gas generator

    Directory of Open Access Journals (Sweden)

    B.D. Lemeshko

    2017-11-01

    Full Text Available The paper describes the operation features of plasma focus chambers using deuterium–tritium mixture. Handling tritium requires the use of sealed, vacuum-tight plasma focus chambers. In these chambers, there is an accumulation of the impurity gases released from the inside surfaces of the electrodes and the insulator while moving plasma current sheath inside chambers interacting with β-electrons generated due to the decay of tritium. Decay of tritium is also accompanied by the accumulation of helium. Impurities lead to a decreased yield of neutron emission from plasma focus chambers, especially for long term operation. The paper presents an option of absorption type gas generator in the chamber based on porous titanium, which allows to significantly increase the lifetime and shelf life of tritium chambers. It also shows the results of experiments on the comparison of the operation of sealed plasma focus chambers with and without the gas generator. Keywords: Plasma focus, Neutron yield, Tritium-filled plasma focus chambers, PACS Codes: 29.25.-v, 52.58.Lq

  13. Experimental studies of plasma wake-field acceleration and focusing

    International Nuclear Information System (INIS)

    Rosenzweig, J.B.; Cole, B.; Ho, C.; Argonne National Lab., IL

    1989-01-01

    More than four years after the initial proposal of the Plasma Wake-field Accelerator (PWFA), it continues to be the object of much investigation, due to the promise of the ultra-high accelerating gradients that can exist in relativistic plasma waves driven in the wake of charged particle beams. These large amplitude plasma wake-fields are of interest in the laboratory, both for the wealth of basic nonlinear plasma wave phenomena which can be studied, as well as for the applications of acceleration of focusing of electrons and positrons in future linear colliders. Plasma wake-field waves are also of importance in nature, due to their possible role in direct cosmic ray acceleration. The purpose of the present work is to review the recent experimental advances made in PWFA research at Argonne National Laboratory, in which many interesting beam and plasma phenomena have been observed. Emphasis is given to discussion of the nonlinear aspects of the PWFA beam-plasma interaction. 29 refs., 13 figs

  14. Numerical Experiments Providing New Insights into Plasma Focus Fusion Devices

    Directory of Open Access Journals (Sweden)

    Sing Lee

    2010-04-01

    Full Text Available Recent extensive and systematic numerical experiments have uncovered new insights into plasma focus fusion devices including the following: (1 a plasma current limitation effect, as device static inductance is reduced towards very small values; (2 scaling laws of neutron yield and soft x-ray yield as functions of storage energies and currents; (3 a global scaling law for neutron yield as a function of storage energy combining experimental and numerical data showing that scaling deterioration has probably been interpreted as neutron ‘saturation’; and (4 a fundamental cause of neutron ‘saturation’. The ground-breaking insights thus gained may completely change the directions of plasma focus fusion research.

  15. Pinches and micropinches in the SPEED 2 plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Roewekamp, P; Decker, G; Kies, W; Lucas, B; Schmitz, F; Ziethen, G [Heinrich-Heine-Univ., Duesseldorf (Germany). Institut fuer Experimentalphysik; Simanovskij, D M; Bobashev, S V [Russian Academy of Sciences, St. Petersburg (Russian Federation). A.F. Ioffe Physico-Technical Inst.

    1997-12-31

    The discharges in the SPEED 2 Plasma Focus as well as other pinch plasmas generated in a plasma focus configuration exhibit two different modes. The micropinch mode is experimentally investigated in detail and well theoretically modelled. Therefore its characteristics e.g. temperature, density, life time and energy output are well known. Nevertheless the micropinches appear very erratic in space and time and their optimization and application is rather difficult. In contrast to this the column mode is not equally well understood yet. Its remarkable features are the unexpectedly high stability (also if the critical current for radiative collapse is exceeded) and its reproducibility, which are important for applications in soft x-ray microscopy or lithography. (J.U.). 6 figs., 9 refs.

  16. Study of electron beam production by a plasma focus

    International Nuclear Information System (INIS)

    Smith, J.R.; Luo, C.M.; Rhee, M.J.; Schneider, R.F.

    1983-01-01

    A preliminary investigation of the electron beam produced by a plasma focus device using a current charged transmission line is described. Electron beam currents as high as 10 kA were measured. Interaction of the extracted beam and the filling gas was studied using open shutter photography

  17. A Plasma Focus operated at a very low pressure range

    International Nuclear Information System (INIS)

    Bruzzone, H.; Grondona, D.; Kelly, H.; Marquez, A.

    1990-01-01

    Several characteristics of the neutron production and the hard X-ray emission from a Plasma Focus device operating at 30 kV (6 kV of stored energy) and at an unusually low pressure range are presented. (Author)

  18. Multi-scaling of the dense plasma focus

    Science.gov (United States)

    Saw, S. H.; Lee, S.

    2015-03-01

    The dense plasma focus is a copious source of multi-radiations with many potential new applications of special interest such as in advanced SXR lithography, materials synthesizing and testing, medical isotopes and imaging. This paper reviews the series of numerical experiments conducted using the Lee model code to obtain the scaling laws of the multi-radiations.

  19. Application of an impedance matching transformer to a plasma focus.

    Science.gov (United States)

    Bures, B L; James, C; Krishnan, M; Adler, R

    2011-10-01

    A plasma focus was constructed using an impedance matching transformer to improve power transfer between the pulse power and the dynamic plasma load. The system relied on two switches and twelve transformer cores to produce a 100 kA pulse in short circuit on the secondary at 27 kV on the primary with 110 J stored. With the two transformer systems in parallel, the Thevenin equivalent circuit parameters on the secondary side of the driver are: C = 10.9 μF, V(0) = 4.5 kV, L = 17 nH, and R = 5 mΩ. An equivalent direct drive circuit would require a large number of switches in parallel, to achieve the same Thevenin equivalent. The benefits of this approach are replacement of consumable switches with non-consumable transformer cores, reduction of the driver inductance and resistance as viewed by the dynamic load, and reduction of the stored energy to produce a given peak current. The system is designed to operate at 100 Hz, so minimizing the stored energy results in less load on the thermal management system. When operated at 1 Hz, the neutron yield from the transformer matched plasma focus was similar to the neutron yield from a conventional (directly driven) plasma focus at the same peak current.

  20. Repetitively pulsed capacitor bank for the dense-plasma focus

    International Nuclear Information System (INIS)

    Zucker, O.; Bostick, W.; Gullickson, R.; Long, J.; Luce, J.; Sahlin, H.

    1975-12-01

    This report describes a 1 pulse per second capacitor bank designed to energize a dense-plasma focus (DPF). The DPF is a neutron source capable (with moderate scaling) of delivering a minimum of 10 15 neutrons per pulse or neutron flux of 2 x 10 13 N/cm 2 .s. The average power consumption, which has become a major issue due to the energy crisis, is analyzed with respect to other plasma devices and is shown to be highly favorable. This small source size high flux neutron source could be extemely useful to qualify fission reactor material irradiation results for fusion reactor design

  1. Design of a repetitively pulsed megajoule dense-plasma focus

    International Nuclear Information System (INIS)

    Zucker, O.; Bostick, W.; Gullickson, R.; Long, J.; Luce, J.; Sahlin, H.

    1975-01-01

    This report describes a 1 pulse per second, dense-plasma-focus (DPF) materials-testing device capable of delivering a minimum of 10 15 neutrons per pulse. Moderate scaling up from existing designs is shown to be sufficient to provide 2 x 10 13 neutrons/ cm 2 . s to a suitable target. The average power consumption, which has become a major issue due to the energy crisis, is analyzed with respect to other plasma devices and is shown to be highly favorable. Also discussed is a novel approach to capacitor-bank and switch design with respect to repetitive-pulse operation. (auth)

  2. Repetitively pulsed capacitor bank for the dense-plasma focus

    International Nuclear Information System (INIS)

    Zucker, O.; Bostick, W.; Gullickson, R.; Long, J.; Luce, J.; Sahlin, H.

    1976-01-01

    This report describes a 1 pulse per second capacitor bank designed to energize a dense-plasma focus (DPF). The DPF is a neutron source capable (with moderate scaling) of delivering a minimum of 10 15 neutrons per pulse or neutron flux of 2 x 10 13 N/cm 2 . s. The average power consumption, which has become a major issue due to the energy crisis, is analyzed with respect to other plasma devices and is shown to be highly favorable. This small source size high flux neutron source could be extremely useful to qualify fission reactor material irradiation results for fusion reactor design

  3. Production of radioisotopes within a plasma focus device

    International Nuclear Information System (INIS)

    Angeli, E.; Tartari, A.; Frignani, M.; Molinari, V.; Mostacci, D.; Rocchi, F.; Sumini, M. . E-mail address of corresponding author: domiziano.mostacci@mail.ing.unibo.it

    2005-01-01

    In recent years, research conducted in the US and in Italy has demonstrated production of radioisotopes in Plasma Focus (PF) devices, and particularly, on what could be termed 'endogenous' production, to wit, production within the plasma itself, as opposed to irradiation of targets. This technique relies on the formation of localized small plasma zones characterized by very high densities and fairly high temperatures. The conditions prevailing in these zones lead to high nuclear reaction rates, as pointed out in previous work by several authors. Further investigation of the cross sections involved has proven necessary to model the phenomena involved. In this paper, the present status of research in this field is reviewed, both with regards to cross section models and to experimental production of radioisotopes. Possible outcomes and further development are discussed. (author)

  4. Time correlation between plasma behaviour and soft x-ray emission in a plasma focus

    International Nuclear Information System (INIS)

    Hirano, Katsumi; Tagaya, Yutaka; Shimoda, Katsuji; Okabe, Yushiro; Yamamoto, Toshikazu

    1986-01-01

    Soft X-rays emitted from a plasma focus are investigated experimentally. In contrast to single-pulsive burst of neutron, hard X-rays, ion- and electron beams, the soft X-rays are observed from the collapse phase to the decay phase of the plasma column, and have typically three successive peaks in its signal. Each peak corresponds to the maximum compression, the disruption and the decay phase of plasma column. It is revealed that the first and the second peaks are radiated by plasma itself, whereas the third peak is caused by emission from the inner electrode face. (author)

  5. Temporal evolution of ion energy in a plasma focus

    International Nuclear Information System (INIS)

    Rhee, M.J.; Weidman, D.J.

    1988-01-01

    For the first time, the temporal structure of ion energy in a plasma focus is revealed using a time-resolving Thomson spectrometer. The velocities and arrival times of ions are determined from the spectrogram. The resulting distribution of ions in velocity--time space at the source is found to be a line distribution, as if the ions were accelerated in a diode by a pulsed voltage

  6. Plasma Channel Lenses and Plasma Tornadoes for Optical Beam Focusing and Transport

    Science.gov (United States)

    Hubbard, R. F.; Kaganovich, D.; Johnson, L. A.; Gordon, D. F.; Penano, J. R.; Hafizi, B.; Helle, M. H.; Mamonau, A. A.

    2017-10-01

    Shaped plasmas offer the possibility of manipulating laser pulses at intensities far above the damage limits for conventional optics. An example is the plasma channel, which is a cylindrical plasma column with an on-axis density minimum. Long plasma channels have been widely used to guide intense laser pulses, particularly in laser wakefield accelerators. A new concept, the ``plasma tornado'', offers the possibility of creating long plasma channels with no nearby structures and at densities lower than can be achieved by capillary discharges. A short plasma channel can focus a laser pulse in much the same manner as a conventional lens or off-axis parabola. When placed in front of the focal point of an intense laser pulse, a plasma channel lens (PCL) can reduce the effective f-number of conventional focusing optics. When placed beyond the focal point, it can act as a collimator. We will present experimental and modeling results for a new plasma tornado design, review experimental methods for generating short PCLs, and discuss potential applications. Supported by the Naval Research Laboratory Base Program.

  7. Preliminary studies of the plasma focus as an opening switch

    International Nuclear Information System (INIS)

    Venneri, F.; Gerdin, G.

    1983-01-01

    Sharp current interruption at pinch time suggests the possible application of the plasma focus as an opening switch. Switch impedances on the order of 0.5 ohms or greater would be of interest to pulsed power applications if the rise time for the impedance is sufficiently short. The experimental determination of the magnitude of the plasma focus impedance at pinch time and its nature (R or L) are obviously important in assessing the feasibility of this application. An experimental estimate of the Spitzer resistance of the plasma focus based on soft-X-ray measurements indicates a Spitzer resistance of 9 mΩ. Estimates of resistance based on the maximum particle energy observed 4 (V about E /sub MAX/ /e) and the current at pinch time (R about E /sub MAX/ /eI /sub p/ ) would indicate an effective resistance of about one ohm. Estimates of resistance based on circuit parameters (L, I, q/C) yield about one third of an ohm. To resolve these discrepancies a exclamationBexclamation probe 5 is being developed to get a better estimate of L(t), L(t) and I(t) through spatially resolved measurements. Preliminary results are reported

  8. The Relationship Between Personality Type And Leadership Focus

    Directory of Open Access Journals (Sweden)

    Grant Sieff

    2006-11-01

    Full Text Available Optimising focus is a key success driver for many organisation leaders. The relationship between personality type and leadership focus is examined. Personality type is assessed with Form M of the Myers-Briggs Type Indicator instrument, and leadership focus is explored through the development and application of a Leadership Focus Questionnaire. South African executives form the target population for this study. Both functionalist and interpretive approaches are applied. Three primary theoretical hypotheses about leadership focus, concerning (1 optimising the balance of focus between external and internal priorities, (2 the fit between the leadership personality type and the organisation type, and (3 the capacity to manage a multiple focus, are considered. Results show that Extraverted personality types are more comfortable with the challenges of focus in the leadership role than are Introverted types, and Extraverted, Sensing, Thinking and Judging types experience a greater degree of fit with their organisations than do Introverted, Intuitive, Feeling and Perceiving types.

  9. Current and Perspective Applications of Dense Plasma Focus Devices

    Science.gov (United States)

    Gribkov, V. A.

    2008-04-01

    Dense Plasma Focus (DPF) devices' applications, which are intended to support the main-stream large-scale nuclear fusion programs (NFP) from one side (both in fundamental problems of Dense Magnetized Plasma physics and in its engineering issues) as well as elaborated for an immediate use in a number of fields from the other one, are described. In the first direction such problems as self-generated magnetic fields, implosion stability of plasma shells having a high aspect ratio, etc. are important for the Inertial Confinement Fusion (ICF) programs (e.g. as NIF), whereas different problems of current disruption phenomenon, plasma turbulence, mechanisms of generation of fast particles and neutrons in magnetized plasmas are of great interest for the large devices of the Magnetic Plasma Confinement—MPC (e.g. as ITER). In a sphere of the engineering problems of NFP it is shown that in particular the radiation material sciences have DPF as a very efficient tool for radiation tests of prospect materials and for improvement of their characteristics. In the field of broad-band current applications some results obtained in the fields of radiation material sciences, radiobiology, nuclear medicine, express Neutron Activation Analysis (including a single-shot interrogation of hidden illegal objects), dynamic non-destructive quality control, X-Ray microlithography and micromachining, and micro-radiography are presented. As the examples of the potential future applications it is proposed to use DPF as a powerful high-flux neutron source to generate very powerful pulses of neutrons in the nanosecond (ns) range of its duration for innovative experiments in nuclear physics, for the goals of radiation treatment of malignant tumors, for neutron tests of materials of the first wall, blankets and NFP device's constructions (with fluences up to 1 dpa per a year term), and ns pulses of fast electrons, neutrons and hard X-Rays for brachytherapy.

  10. Current and Perspective Applications of Dense Plasma Focus Devices

    International Nuclear Information System (INIS)

    Gribkov, V. A.

    2008-01-01

    Dense Plasma Focus (DPF) devices' applications, which are intended to support the main-stream large-scale nuclear fusion programs (NFP) from one side (both in fundamental problems of Dense Magnetized Plasma physics and in its engineering issues) as well as elaborated for an immediate use in a number of fields from the other one, are described. In the first direction such problems as self-generated magnetic fields, implosion stability of plasma shells having a high aspect ratio, etc. are important for the Inertial Confinement Fusion (ICF) programs (e.g. as NIF), whereas different problems of current disruption phenomenon, plasma turbulence, mechanisms of generation of fast particles and neutrons in magnetized plasmas are of great interest for the large devices of the Magnetic Plasma Confinement--MPC (e.g. as ITER). In a sphere of the engineering problems of NFP it is shown that in particular the radiation material sciences have DPF as a very efficient tool for radiation tests of prospect materials and for improvement of their characteristics. In the field of broad-band current applications some results obtained in the fields of radiation material sciences, radiobiology, nuclear medicine, express Neutron Activation Analysis (including a single-shot interrogation of hidden illegal objects), dynamic non-destructive quality control, X-Ray microlithography and micromachining, and micro-radiography are presented. As the examples of the potential future applications it is proposed to use DPF as a powerful high-flux neutron source to generate very powerful pulses of neutrons in the nanosecond (ns) range of its duration for innovative experiments in nuclear physics, for the goals of radiation treatment of malignant tumors, for neutron tests of materials of the first wall, blankets and NFP device's constructions (with fluences up to 1 dpa per a year term), and ns pulses of fast electrons, neutrons and hard X-Rays for brachytherapy

  11. Preionization Techniques in a kJ-Scale Dense Plasma Focus

    Science.gov (United States)

    Povilus, Alexander; Shaw, Brian; Chapman, Steve; Podpaly, Yuri; Cooper, Christopher; Falabella, Steve; Prasad, Rahul; Schmidt, Andrea

    2016-10-01

    A dense plasma focus (DPF) is a type of z-pinch device that uses a high current, coaxial plasma gun with an implosion phase to generate dense plasmas. These devices can accelerate a beam of ions to MeV-scale energies through strong electric fields generated by instabilities during the implosion of the plasma sheath. The formation of these instabilities, however, relies strongly on the history of the plasma sheath in the device, including the evolution of the gas breakdown in the device. In an effort to reduce variability in the performance of the device, we attempt to control the initial gas breakdown in the device by seeding the system with free charges before the main power pulse arrives. We report on the effectiveness of two techniques developed for a kJ-scale DPF at LLNL, a miniature primer spark gap and pulsed, 255nm LED illumination. Prepared by LLNL under Contract DE-AC52-07NA27344.

  12. Observation of intense beam in low pressure from IPR Plasma Focus facility

    International Nuclear Information System (INIS)

    Kumar, R.; Shyam, A.; Chaturvedi, S.; Lathi, D.; Sarkar, Partha; Chaudhari, V.; Verma, R.; Shukla, R.; Debnath, K.; Sonara, J.; Shah, K.; Adhikary, B.

    2004-01-01

    Full text: Plasma focus (PF) is a powerful source of various ionizing radiation such as charged particles beam (ions and electrons), X-ray, neutrons etc. This device can operate from energy level of 50J to 1MJ. Plasma Focus is relatively small, simple and cheap in comparison with other radiation sources based on isotopes, accelerators and fusion reactors. Radiation pulse from PF is strong and very short. Now with the new pulsed power technology this device can be operated repeatedly with enhanced lifetime. All these features make plasma focus a versatile device for academic as well as industrial interest such as hot plasma physics and plasma collective processes, equation of state of matter under extreme conditions, material science including material characterization, dynamic equation control, and surface modification and destruction test. Intense burst of neutrons have been observed from a low energy (3.6 kJ) Mather type plasma focus device operated in 0.4 Torr pressure of deuterium medium at IPR. The emitted neutrons (10 9 /shot), that are accompanied by a strong hard X-ray pulse, were found to be having energy up to 3.26 MeV in the axial direction of the device

  13. Dose Measurements in a 20-J Repetitive Plasma Focus

    Science.gov (United States)

    Goudarzi, S.; Babaee, H.; Esmaeli, A.; Nasiri, A.; Mazandarani, A.

    2018-02-01

    In this article, the results of X-ray dose measurements executed using thermoluminescent dosimeters in experiments with a very small (20 J) repetitive plasma focus device named SORENA-1 are presented and analyzed. The working gas in these experiments was Argon. Also, pinch formation in experiments with this device has been observed. This device has been designed and constructed in Plasma and Nuclear Fusion Research School of Nuclear Science and Technology Research Institute of Iran. From these results, it is concluded that we can do experiments with this device using Ar as working gas all over the working days of year, and a good symmetry for measured dose around the device has been seen.

  14. Study of microwave emission from a dense plasma focus

    International Nuclear Information System (INIS)

    Gerdin, G.; Venneri, F.; Tanisi, M.

    1985-01-01

    Microwave emission was detected in a 12.5 kJ dense plasma focus, using microwave horns and detectors placed in various locations outside the device. The results show that the parallel plates connecting the focus to its capacitor banks act as antennas and transmission lines, rather than wave guides. Subsequent measurements were performed with a microwave detector (R-band) attached to the focus anode, directly looking into the coaxial gun region, allowing to restrict the microwave emitting region to the muzzle end of the focus. The microwave frequency spectrum, determined with a time of flight detection system, strongly suggests the lower hybrid instability as the driving mechanism of the emissions. Comparing the time sequence of the emissions with those of other observable phenomena in the focus, a model was developed, to explain the possible relationship between the generation of microwave radiation and turbulence induced resistivity in the focus pinch. According to the model, microwaves and enhanced resistivity are caused by current driven instabilities occurring in the current sheath produced at the outer boundary of the pinch during the initial compression phase. Comparisons of the model predictions with observed experimental results are presented, including time resolved measurements of the pinch resistivity

  15. Interaction of powerful hot plasma and fast ion streams with materials in dense plasma focus devices

    Czech Academy of Sciences Publication Activity Database

    Chernyshova, M.; Gribkov, V. A.; Kowalska-Strzeciwilk, E.; Kubkowska, M.; Miklaszewski, R.; Paduch, M.; Pisarczyk, T.; Zielinska, E.; Demina, E.V.; Pimenov, V. N.; Maslyaev, S. A.; Bondarenko, G.G.; Vilémová, Monika; Matějíček, Jiří

    2016-01-01

    Roč. 113, December (2016), s. 109-118 ISSN 0920-3796 R&D Projects: GA ČR(CZ) GA14-12837S Institutional support: RVO:61389021 Keywords : Radiation damageability * Materials tests * Plasma focus * Plasma streams * Ion beams * Laser interferometrya Subject RIV: JF - Nuclear Energetics OBOR OECD: Nuclear related engineering Impact factor: 1.319, year: 2016 http://www.sciencedirect.com/science/article/pii/S0920379616306858

  16. Dynamics of the plasma current sheath in plasma focus discharges in different gases

    Energy Technology Data Exchange (ETDEWEB)

    Vinogradov, V. P.; Krauz, V. I., E-mail: krauz-vi@nrcki.ru [National Research Center Kurchatov Institute (Russian Federation); Mokeev, A. N. [Project Center ITER (Russian Federation); Myalton, V. V.; Kharrasov, A. M. [National Research Center Kurchatov Institute (Russian Federation)

    2016-12-15

    The shape of the plasma current sheath (PCS) in the final stage of its radial compression, the dynamics of pinching, and the subsequent pinch decay in plasma focus (PF) discharges in different gases are studied using an improved multichannel system of electron-optical plasma photography and a newly elaborated synchronization system. The PCS structure in discharges in heavy gases (Ne, Ar) is found to differ significantly from that in discharges in hydrogen and deuterium. The influence of a heavy gas (Xe) additive to hydrogen and deuterium on the structure and compression dynamics of the PCS is investigated.

  17. Plasma focus sources: Supplement to the neutron resonance radiography workshop proceedings

    International Nuclear Information System (INIS)

    Nardi, V.; Brzosko, J.

    1989-01-01

    Since their discovery, plasma focus discharges have been recognized as very intense pulsed sources of deuterium-deuterium (D-D) or deuterium-tritium (D-T) fusion-reaction neutrons, with outstanding capabilities. Specifically, the total neutron emission/shot, YN, and the rate of neutron emission, Y/sub n/, of an optimized plasma focus (PF) are higher than the corresponding quantities observed in any other type of pinched discharge at the same level of powering energy W 0 . Recent developments have led to the concept and experimental demonstration of an Advanced Plasma Focus System (APF) that consists of a Mather-geometry plasma focus in which field distortion elements (FDEs) are inserted in the inter-electrode gap for increasing the neutron yield/shot, Y/sub n/. The FDE-induced redistribution of the plasma current increases Y/sub n/ by a factor ≅5-10 above the value obtained without FDEs under otherwise identical conditions of operation of the plasma focus. For example, an APF that is fed by a fast capacitor bank with an energy, W 0 = 6kJ, and voltage, V 0 = 16.5 kV provides Y/sub n/ /congruent/ 4 /times/ 10 9 D-D neutrons/shot (pure D 2 filling) and Y/sub n/ = 4 /times/ 10 11 D-T neutrons/shot (filling is 50% deuterium and 50% tritium). The FDE-induced increase of Y/sub n/ for fixed values of (W 0 , V 0 ), the observed scaling law Y/sub n/ /proportional to/ W 0 2 for optimized plasma focus systems, and our experience with neutron scattering in bulk objects lead us to the conclusion that we can use an APF as a source of high-intensity neutron pulses (10 14 n/pulse) in the field off neutron radiography (surface and bulk) with a nanosecond or millisecond time resolution

  18. Experimental investigations of plasma lens focusing and plasma channel transport of heavy ion beams

    International Nuclear Information System (INIS)

    Tauschwitz, T.; Yu, S.S.; Eylon, S.; Reginato, L.; Leemans, W.; Rasmussen, J.O.; Bangerter, R.O.

    1995-04-01

    Final focusing of ion beams and propagation in a reactor chamber are crucial questions for heavy ion beam driven Fusion. An alternative solution to ballistic quadrupole focusing, as it is proposed in most reactor studies today, is the utilization of the magnetic field produced by a high current plasma discharge. This plasma lens focusing concept relaxes the requirements for low emittance and energy spread of the driver beam significantly and allows to separate the issues of focusing, which can be accomplished outside the reactor chamber, and of beam transport inside the reactor. For focusing a tapered wall-stabilized discharge is proposed, a concept successfully demonstrated at GSI, Germany. For beam transport a laser pre-ionized channel can be used

  19. The plasma focus as a large fluence neutron source

    International Nuclear Information System (INIS)

    Zucker, O.; Bostick, W.; Long, J.; Luce, J.; Sahlin, H.

    1977-01-01

    A continuously operated, 1 pps, dense-plasma-focus device capable of delivering a minimum of 10 15 neutrons per pulse for material testing purposes is described. With I 5 scaling, predicted from analysis of existing machines, yields of 10 16 -10 17 neutrons per pulse are postulated. The average power consumption, which has become a major issue as a result of the energy crisis is shown to be highly favorable. A novel approach to the capacitor bank and switch design allowing repetitive operation is discussed. (Auth.)

  20. Flow morphing by coaxial type plasma actuator

    Science.gov (United States)

    Toyoizumi, S.; Aono, H.; Ishikawa, H.

    2017-04-01

    The purpose of study is to achieve the fluid drag reduction of a circular disk by Dielectric Barrier Discharge Plasma Actuator (DBD-PA). We here introduced “Flow Morphing” concept that flow around the body was changed by DBD-PA jet, such as the body shape morphing. Coaxial type DBD-PA injected axisymmetric jet, generating the vortex region on the pressure side of the circular disk. The vortex generated by axisymmetric plasma jet and flow around circular disk were visualized by tracer particles method. The fluid drag was measured by compression type load cell. In addition streamwise velocity was measured by an X-type hot wire probe. The extent of fluid drag reduction by coaxial type DBD-PA jet was influenced by the volume of vortex region and the diameter of plasma electrode.

  1. Density profile measurements from a two-gun plasma focus device

    International Nuclear Information System (INIS)

    Tzeng, C.C.; Yen, C.K.; Yeh, T.R.; Kuo, Y.Y.; Shang, D.J.; Yu, Y.Z.; Hou, W.S.

    1990-01-01

    The dynamics of the plasma evolution in a two-gun plasma focus device has been studied using the laser shadowgraphy as well as the laser interferometry. The experiments were carried out from a 700 kJ two-gun plasma focus device reported earlier, which consisted of a pair of Mather type coaxial electrodes connected muzzle to muzzle. Previous results indicated that the simultaneous formation of the two deuterium plasma foci occurred earlier and then after ∼ 100 ns a disk-shaped plasma of ∼ 1.5 cm in diameter appeared in the middle region between the anodes. It is, therefore, the authors' goal to study the density profiles in the plasma foci and the middle region in order to understand further the formation of the plasma foci and their time evolution. The laser shadowgraphy was done with a XeCl excimer pumped dye laser system which operated at 550 nm with pulse width of ∼ 10 ns. The laser interferometry, on the other hand, was carried out using a TEA-TEA oscillator-amplifier N 2 -laser system with 337.1 nm and subnano-second pulse width. Both results show that the maximum electron density is ≥2 x 10 19 cm -3 and, in addition, the growth of the hydrodynamic instabilities are observed. These results together with the detailed density profiles are presented and discussed

  2. ''Flicker'' in laser-plasma self-focusing

    International Nuclear Information System (INIS)

    Coggeshall, S.V.; Mead, W.C.; Jones, R.D.

    1988-01-01

    Under certain conditions, a new mode of laser-plasma self-focusing can occur which is characterized by a self-sustaining, continual shifting of filament-produced focal spots and a somewhat chaotic redistribution of light at the critical surface. Associated with this phenomenon is the possibility of significant intensity multiplication due to self-focusing. This flickering of laser light is caused by small amplitude, short wavelength ion acoustic waves which are produced near the foci of the filaments and subsequently propagate and convect toward the laser. As these ion fluctuations move toward the laser, they cause further light ray trajectory changes which shift the locations of the foci. New sound waves are launched and the process is self-perpetuated. 7 refs., 5 figs

  3. Editorial: Focus on Laser- and Beam-Driven Plasma Accelerators

    Science.gov (United States)

    Joshi, Chan; Malka, Victor

    2010-04-01

    The ability of short but intense laser pulses to generate high-energy electrons and ions from gaseous and solid targets has been well known since the early days of the laser fusion program. However, during the past decade there has been an explosion of experimental and theoretical activity in this area of laser-matter interaction, driven by the prospect of realizing table-top plasma accelerators for research, medical and industrial uses, and also relatively small and inexpensive plasma accelerators for high-energy physics at the frontier of particle physics. In this focus issue on laser- and beam-driven plasma accelerators, the latest advances in this field are described. Focus on Laser- and Beam-Driven Plasma Accelerators Contents Slow wave plasma structures for direct electron acceleration B D Layer, J P Palastro, A G York, T M Antonsen and H M Milchberg Cold injection for electron wakefield acceleration X Davoine, A Beck, A Lifschitz, V Malka and E Lefebvre Enhanced proton flux in the MeV range by defocused laser irradiation J S Green, D C Carroll, C Brenner, B Dromey, P S Foster, S Kar, Y T Li, K Markey, P McKenna, D Neely, A P L Robinson, M J V Streeter, M Tolley, C-G Wahlström, M H Xu and M Zepf Dose-dependent biological damage of tumour cells by laser-accelerated proton beams S D Kraft, C Richter, K Zeil, M Baumann, E Beyreuther, S Bock, M Bussmann, T E Cowan, Y Dammene, W Enghardt, U Helbig, L Karsch, T Kluge, L Laschinsky, E Lessmann, J Metzkes, D Naumburger, R Sauerbrey, M. Scḧrer, M Sobiella, J Woithe, U Schramm and J Pawelke The optimum plasma density for plasma wakefield excitation in the blowout regime W Lu, W An, M Zhou, C Joshi, C Huang and W B Mori Plasma wakefield acceleration experiments at FACET M J Hogan, T O Raubenheimer, A Seryi, P Muggli, T Katsouleas, C Huang, W Lu, W An, K A Marsh, W B Mori, C E Clayton and C Joshi Electron trapping and acceleration on a downward density ramp: a two-stage approach R M G M Trines, R Bingham, Z Najmudin

  4. Oscillation of the current sheet velocity in plasma focus discharges

    International Nuclear Information System (INIS)

    Melzacki, K.; Nardi, V.

    1994-01-01

    The oscillation of the propagation speed of the plasma focus current sheet has been recorded with schlieren photography. The sheet stuttering in the propagation during the implosion phase has a frequency of about 60 MHz. The effect could be recorded due to application of long exposure time (60 ns) technique. It is not detectable in the subnanosecond pictures. The pictures are taken in black schlieren. The probing range of the electron density gradient, with integration along the path of the 1 J, Q-switched ruby laser beam, has been selected by the size of the stop and aperture within 3 x 10 18 cm -3 and 3 x 10 20 cm -3 . Raising the sensitivity threshold to 2 x 10 19 cm -3 (refraction angle of 4 mrad) has helped to clear the pictures by limiting their image to high gradients of density only. With this technique (and other diagnostic methods) the dynamics of 6 kJ, 16 kV plasma focus discharges in deuterium at 5 torr, with a 10% decrease of the magnetic insulation at the breech has been investigated. The average implosion velocity of the current sheath obtained with this effect, 5 x 10 6 cm/s, is consistent with those measured by the smear effect, and the electric probe. The electron density gradient has been determined at several instants; at the pinch time it is (3 ± 1.5) x 10 20 cm -4 . The data are discussed on the basis of several pictures

  5. Instabilities in the 'on' phase of the plasma focus

    International Nuclear Information System (INIS)

    Kaeppeler, H.J.

    1990-07-01

    In the operation of large plasma focus devices, e.g. POSEIDON, there appear saturation phenomena in the neutron production when the charging energy of the condensor bank approaches its nominal value. This saturation is attributed to the action of impurities. It is assumed that there appear instabilities which are in part caused by impurities. In order to be able to answer this question, the linear dispersion relation was derived from a three-fluid theory (electrons, ions and neutrals) with the aid of the computer algebra (CA) code MACSYMA. The inversion of the 17x17 matrix (it is assumed that v a =v i and T a =T i ) and solution of the determinant was carried out on a CONVEX C 120 computer using the CA code MAPLE. The calculation of the zeros was done with a modified CPZERO program from the SLATEC library. There appear four instabilities in the rundown phase of the plasma focus, two of them gradient driven. The first two are unstable electrostatic waves with very high phase velocities, thus they do not contribute to anomalous dissipation. The third is identified as a gradient driven space charge instability which may possibly lead to current chopping. The electron acoustic wave instability, here gradient driven, is the fourth. It was found in a previous study of MPD thruster instabilities. (orig.)

  6. Compact and tunable focusing device for plasma wakefield acceleration

    Science.gov (United States)

    Pompili, R.; Anania, M. P.; Chiadroni, E.; Cianchi, A.; Ferrario, M.; Lollo, V.; Notargiacomo, A.; Picardi, L.; Ronsivalle, C.; Rosenzweig, J. B.; Shpakov, V.; Vannozzi, A.

    2018-03-01

    Plasma wakefield acceleration, either driven by ultra-short laser pulses or electron bunches, represents one of the most promising techniques able to overcome the limits of conventional RF technology and allows the development of compact accelerators. In the particle beam-driven scenario, ultra-short bunches with tiny spot sizes are required to enhance the accelerating gradient and preserve the emittance and energy spread of the accelerated bunch. To achieve such tight transverse beam sizes, a focusing system with short focal length is mandatory. Here we discuss the development of a compact and tunable system consisting of three small-bore permanent-magnet quadrupoles with 520 T/m field gradient. The device has been designed in view of the plasma acceleration experiments planned at the SPARC_LAB test-facility. Being the field gradient fixed, the focusing is adjusted by tuning the relative position of the three magnets with nanometer resolution. Details about its magnetic design, beam-dynamics simulations, and preliminary results are examined in the paper.

  7. Energy analysis of the ion beam from plasma focus

    International Nuclear Information System (INIS)

    Kilic, H.; Nardi, V.; Prior, W.

    1984-01-01

    The authors have experimentally determined the energy spectrum of a deuteron beam in the energy interval 100 KeV ≤ E ≤ 10 MeV, with typical beam current I ≥ 1-2 A. A 5 kJ (15 kV, 49 μF) plasma focus machine is used to generate the ion beam at relatively low pressure 3-4 Torr D/sub 2/ (beam anode) and at higher pressure 6-8 Torr D/sub 2/ (high-neutron-yield mode). The spectrum is obtained from two different methods, i.e. from ion time of flight - by using time delays of Faraday cup signals with respect to hard x-ray signals - and from ion filtering, (mylar filter with different thickness from 2.5 μm up to 500 μm are used to cover the Faraday cup). The Faraday cup is located in a differentially pumed chamber (10/sup -4/ - 10/sup -5/ Torr) which is separated from the plasma focus chamber (8-3 Torr) by a 150 μm diam. pinhole (12.5 μm thick tungsten foil). The pinhole and Faraday cup are positioned on the gun axis at a distance of 15 cm and 25 cm from the end of the anode respectively

  8. Pinch modes in the SPEED2 plasma focus

    International Nuclear Information System (INIS)

    Kies, W.; Decker, G.; Berntien, U.; Glushkov, D.A.; Sidelnikov, Yu.V.; Koshelev, K.N.; Simanovskij, D.M.; Bobashev, S.V.

    2001-01-01

    Deuterium discharges in the SPEED2 plasma focus (80 kJ, 200 kV, 2 MA, 400 ns) have been found unexpectedly stable within the operational regime as a neutron source. Only at higher filling pressures (above 6 mbar) sometimes m=0 instabilities appeared in the pinch column, especially in discharges of lower efficiency (moderate dynamics and neutron yield). Enhancing the electromagnetic radiation by doping these discharges with heavy gases (e.g. neon, argon) distinctly two pinch modes are produced, the micropinch mode (MPM) or the stable column mode (SCM), with a transition regime where the initial SCM is followed by the MPM. Micropinches are local radiative collapses initiated by m=0 instabilities of low-energy-density pinch plasmas. These instabilities and the successive micropinches can be suppressed by kinetic deuterons produced during dynamical compression of high-energy-density deuterium plasma sheaths. Depending on the relaxation of this fast deuteron component the pinch column can be stabilized for several tens of nanoseconds. While the short-lived (appr.1 ns) micropinches erratically appear as point-like successive flashes along the pinch axis with temperatures about 1 keV and about solid density the reproducible SCM, optimized with respect to the compression ratio, forms a powerful linear radiation source of temperatures and densities similar to the MPM. The SCM needs powerful (fast) drivers in order to use the kinetic ion stabilization, but not necessarily MA currents as available from the SPEED2 driver. This opens the possibility to establish the SCM also in compact experiments like SPEED3 (8 kJ, 80 kV, 0.8 MA, 300 ns) or even SPEED4 (2 kJ, 40 kV 250 kA, 300 ns). (author)

  9. Four-fluid description of turbulent plasma focus dynamics

    International Nuclear Information System (INIS)

    Hayd, A.; Maurer, M.; Meinke, P.; Kaeppeler, H.J.

    1984-06-01

    The dynamic phenomena in the compression, pinch and late phases of the plasma focus experiment POSEIDON in its operational mode at 60 kV, 280 kJ, were previously calculated from a two-fluid theory using the new hybrid code REDUCE/FORTRAN. Two important results were found: the neutron production already in the pinch phase for currents larger than 500 kA and filamentary structures on and around the pinch axis. In a continuation of this work, a four-fluid system of dynamical equations was formulated and programmed with the REDUCE/FORTRAN code. Besides macro-turbulence, the new four-fluid theory includes micro-instabilities and anomalous transport properties, as well as the runaway effect for electrons and ions. First results from calculations with this new theory are presented and are compared with previous calculations and with recent experimental observations. (orig.)

  10. Characterization of bismuth nanospheres deposited by plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, M., E-mail: cscientific2@aec.org.sy [IBA Laboratory, Chemistry Department, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic); Al-Hawat, Sh.; Akel, M. [Physics Department, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic); Mrad, O. [Chemistry Department, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic)

    2015-02-14

    A new method for producing thin layer of bismuth nanospheres based on the use of low energy plasma focus device is demonstrated. Various techniques such as scanning electron microscopy, Rutherford backscattering spectroscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and Raman spectroscopy have been used to characterize the morphology and the composition of the nanospheres. Experimental parameters may be adjusted to favour the formation of bismuth nanospheres instead of microspheres. Therefore, the formation of large surface of homogeneous layer of bismuth nanospheres with sizes of below 100 nm can be obtained. The natural snowball phenomenon is observed to be reproduced in nanoscale where spheres roll over the small nanospheres and grow up to bigger sizes that can reach micro dimensions. The comet-like structure, a reverse phenomenon to snowball is also observed.

  11. Fully kinetic simulations of megajoule-scale dense plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, A.; Link, A.; Tang, V.; Halvorson, C.; May, M. [Lawrence Livermore National Laboratory, Livermore California 94550 (United States); Welch, D. [Voss Scientific, LLC, Albuquerque, New Mexico 87108 (United States); Meehan, B. T.; Hagen, E. C. [National Security Technologies, LLC, Las Vegas, Nevada 89030 (United States)

    2014-10-15

    Dense plasma focus (DPF) Z-pinch devices are sources of copious high energy electrons and ions, x-rays, and neutrons. Megajoule-scale DPFs can generate 10{sup 12} neutrons per pulse in deuterium gas through a combination of thermonuclear and beam-target fusion. However, the details of the neutron production are not fully understood and past optimization efforts of these devices have been largely empirical. Previously, we reported on the first fully kinetic simulations of a kilojoule-scale DPF and demonstrated that both kinetic ions and kinetic electrons are needed to reproduce experimentally observed features, such as charged-particle beam formation and anomalous resistivity. Here, we present the first fully kinetic simulation of a MegaJoule DPF, with predicted ion and neutron spectra, neutron anisotropy, neutron spot size, and time history of neutron production. The total yield predicted by the simulation is in agreement with measured values, validating the kinetic model in a second energy regime.

  12. Simulation of a dense plasma focus x-ray source

    International Nuclear Information System (INIS)

    Stark, R.A.

    1994-01-01

    The authors are performing simulations of the magnetohydrodynamics of a Dense Plasma Focus (DPF) x-ray source located at Science Research Laboratory (SRL), Alameda, CA, in order to optimize its performance. The SRL DPF, which was developed as a compact source for x-ray lithography, operates at 20 Hz, giving x-ray power (9--14 Angstroms) of 500 W using neon gas. The simulations are performed with the two dimensional MHD code MACH2, developed by Mission Research Corporation, with a steady state corona model as the equation of state. The results of studies of the sensitivity of x-ray output to charging voltage and current, and to initial gas density will be presented. These studies should indicate ways to optimize x-ray production efficiency. Simulations of various inner electrode configurations will also be presented

  13. Charged particles beams measurements in plasma focus discharges

    International Nuclear Information System (INIS)

    Jakubowski, L.; Sadowski, M.; Zebrowski, J.

    2001-01-01

    Experimental studies performed with many Plasma-Focus (PF) facilities have shown that simultaneously with the emission of X-ray pulses and intense relativistic electron beams (REBs) there also appears the emission of pulsed ion streams of a relatively high energy (up to several MeV). Such ions are emitted mainly along the z-axis of the PF discharge, although the ion angular distribution is relatively wide. From PF discharges with deuterium filling fast neutrons produced by nuclear fusion reactions are also emitted. The paper concerns studies of the energetic ion beams and their correlation with the pulsed REBs. Time-integrated measurements were performed with an ion pinhole camera equipped with solid-state nuclear track detectors (SSNTDs), and time-resolved studies were carried out with a scintillation detector, enabling the determination of an ion energy spectrum on the basis of the time-of-flight (TOF) technique. (author)

  14. Characterization of bismuth nanospheres deposited by plasma focus device

    International Nuclear Information System (INIS)

    Ahmad, M.; Al-Hawat, Sh.; Akel, M.; Mrad, O.

    2015-01-01

    A new method for producing thin layer of bismuth nanospheres based on the use of low energy plasma focus device is demonstrated. Various techniques such as scanning electron microscopy, Rutherford backscattering spectroscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and Raman spectroscopy have been used to characterize the morphology and the composition of the nanospheres. Experimental parameters may be adjusted to favour the formation of bismuth nanospheres instead of microspheres. Therefore, the formation of large surface of homogeneous layer of bismuth nanospheres with sizes of below 100 nm can be obtained. The natural snowball phenomenon is observed to be reproduced in nanoscale where spheres roll over the small nanospheres and grow up to bigger sizes that can reach micro dimensions. The comet-like structure, a reverse phenomenon to snowball is also observed

  15. Plasma focus as an heavy ion source in the problem of heavy ion fusion

    International Nuclear Information System (INIS)

    Gribkov, V.A.; Dubrovskij, A.V.; Kalachev, N.V.; Krokhin, O.N.; Silin, P.V.; Nikulin, V.Ya.; Cheblukov, Yu.N.

    1984-01-01

    Results of experiments on the ion flux formation in a plasma focus (PF) to develop a multicharged ion source for thermonuclear facility driver are presented. In plasma focus accelerating section copper ions were injected. Advantages of the suggested method of ion beam formation are demonstrated. Beam emittance equalling < 0.1 cmxmrad is obtained. Plasma focus ion energy exceeds 1 MeV. Plasma focus in combination with a neodymium laser is thought to be a perspective ion source for heavy ion fusion

  16. Macroparticle acceleration from a modified mather-type plasma gun

    International Nuclear Information System (INIS)

    Hou, W.S.; Yeh, T.R.; Wen, M.; Yeh, C.K.; Shang, D.J.

    1987-01-01

    The use of electromagnetic force to accelerate projectiles of a few grams in a plasma-driven railgun device was described recently. Since then, subsequent research along this development has been exploited at many laboratories. As part of the plasma focus research project, an effort of modified Mather-type plasma gun has also been constructed at the Institute of Nuclear Energy Research (INER) for impact studies. The idea takes the advantage of accelerating plasmas with JxB force toward the muzzle of the gun and then strikes the projecticle to transfer their kinetic energy. Preliminary results indicate that the projecticle velocity of 1.1 km/sec can be achieved routinely with a 1.2-gram stainless steel projectile

  17. Laser induced focusing for over-dense plasma beams

    International Nuclear Information System (INIS)

    Schmidt, Peter; Boine-Frankenheim, Oliver; Mulser, Peter

    2015-01-01

    The capability of ion acceleration with high power, pulsed lasers has become an active field of research in the past years. In this context, the radiation pressure acceleration (RPA) mechanism has been the topic of numerous theoretical and experimental publications. Within that mechanism, a high power, pulsed laser beam hits a thin film target. In contrast to the target normal sheath acceleration, the entire film target is accelerated as a bulk by the radiation pressure of the laser. Simulations predict heavy ion beams with kinetic energy up to GeV, as well as solid body densities. However, there are several effects which limit the efficiency of the RPA: On the one hand, the Rayleigh-Taylor-instability limits the predicted density. On the other hand, conventional accelerator elements, such as magnetic focusing devices are too bulky to be installed right after the target. Therefore, we present a new beam transport method, suitable for RPA-like/over-dense plasma beams: laser induced focusing

  18. Energy conversion and concentration in a high-current gaseous discharge: Dense plasma spheromak in plasma focus experiments

    International Nuclear Information System (INIS)

    Kukushkin, A.B.; Rantsev-Kartinov, V.A.; Terentiev, A.R.

    1995-01-01

    Experimental results are presented which verify the possibility of the self-generated transformation of the magnetic field in plasma focus discharges to give a closed, spheromak-like magnetic configuration (SLMC). The energy conversion mechanism suggests a possibility of further concentrating the plasma power density by means of natural compressing the SLMC-trapped plasma by the residual magnetic field of the plasma focus discharge

  19. The application of selected radionuclides for monitoring of the D-D reactions produced by dense plasma-focus device.

    Science.gov (United States)

    Jednorog, S; Szydlowski, A; Bienkowska, B; Prokopowicz, R

    The dense plasma focus (DPF) device-DPF-1000U which is operated at the Institute of Plasma Physics and Laser Microfusion is the largest that type plasma experiment in the world. The plasma that is formed in large plasma experiments is characterized by vast numbers of parameters. All of them need to be monitored. A neutron activation method occupies a high position among others plasma diagnostic methods. The above method is off-line, remote, and an integrated one. The plasma which has enough temperature to bring about nuclear fusion reactions is always a strong source of neutrons that leave the reactions area and take along energy and important information on plasma parameters and properties as well. Silver as activated material is used as an effective way of neutrons measurement, especially when they are emitted in the form of short pulses like as it happens from the plasma produced in Dense Plasma-Focus devices. Other elements such as beryllium and yttrium are newly introduced and currently tested at the Institute of Plasma Physics and Laser Microfusion to use them in suitable activation neutron detectors. Some specially designed massive indium samples have been recently adopted for angular neutrons distribution measurements (vertical and horizontal) and have been used in the recent plasma experiment conducted on the DPF-1000U device. This choice was substantiated by relatively long half-lives of the neutron induced isotopes and the threshold character of the 115 In(n,n') 115m In nuclear reaction.

  20. Effect of spin-polarized D-3He fuel on dense plasma focus for space propulsion

    Science.gov (United States)

    Mei-Yu Wang, Choi, Chan K.; Mead, Franklin B.

    1992-01-01

    Spin-polarized D-3He fusion fuel is analyzed to study its effect on the dense plasma focus (DPF) device for space propulsion. The Mather-type plasma focus device is adopted because of the ``axial'' acceleration of the current carrying plasma sheath, like a coaxial plasma gun. The D-3He fuel is chosen based on the neutron-lean fusion reactions with high charged-particle fusion products. Impulsive mode of operation is used with multi-thrusters in order to make higher thrust (F)-to-weight (W) ratio with relatively high value of specific impulse (Isp). Both current (I) scalings with I2 and I8/3 are considered for plasma pinch temperature and capacitor mass. For a 30-day Mars mission, with four thrusters, for example, the typical F/W values ranging from 0.5-0.6 to 0.1-0.2 for I2 and I8/3 scalings, respectively, and the Isp values of above 1600 s are obtained. Parametric studies indicate that the spin-polarized D-3He provides increased values of F/W and Isp over conventional D-3He fuel which was due to the increased fusion power and decreased radiation losses for the spin-polarized case.

  1. Interaction of dense nitrogen plasma with SS304 surface using APF plasma focus device

    Science.gov (United States)

    Afrashteh, M.; Habibi, M.; Heydari, E.

    2012-04-01

    The nitridation of SS304 surfaces is obtained by irradiating nitrogen ions from Amirkabir plasma focus device, which use multiple focus deposition shots at optimum distance 10 cm from the anode. The Vickers Micro-Hardness values are improved more than twice for the nitrided samples comparing to the nonnitrided ones. The X-ray diffraction (XRD) analysis is carried out in order to explore the phase changes in the near surface structure of the metals. The results of Scanning Electron Microscopy (SEM) indicate changes in surface morphology which are the emergence of smooth and uniform film on the surface of the nitrided metals.

  2. Neutron localization measurements from a two-gun plasma focus device

    International Nuclear Information System (INIS)

    Yeh, T.R.; Wen, M.; Tzeng, C.C.; Shang, D.J.; Yeh, C.K.; Wu, K.S.; Kuo, Y.Y.; Hou, W.S.

    1989-01-01

    The simultaneous formation of the two deuterium plasma foci has been reported recently by Hou, W.S., et al, in Procs I.E.E.E. Int. Conf. on Plasma Science, 1986, 87, in a Mather type two-gun plasma focus assembly with maximum bank energy of ∼700 kJ. In addition, these plasmas will evolve and then produce a disk-shaped plasma in the middle of the two plasma foci. Soft X-ray filter techniques which allow measurements of the electron temperature at both pinch points and the middle point yielded a few hundred eV for these three regions. Neutron localization measurements which were carried out with a collimator and a scintillator-fiber-photomultiplier assembly indicate that an enhancement of ∼80% in neutron yield is observed in the middle region as the separation between two electrodes is 9.1 cm. Further experimental evidence shows that the neutron production in the middle region is the result of the beam-beam interaction in nature. (author)

  3. Construction and characterization of a plasma focus device and diagnostic test ion

    International Nuclear Information System (INIS)

    Morales Arango, Diana Marsela

    2013-01-01

    In this work we designed and built a Plasma Focus device 2kJ power in order to extend the energy range of devices designed in DPTN CCHEN and study the scaling laws type Plasma Focus Device. The operating parameters of this device are: T/ 4 =907ns, C = 8000nF, L = 42nH, E = 2kJ, lo = 276kA. In such a way to optimize the device tests were performed with various electrode configurations, insulator length, to determine the conditions under which it operates in Plasma Focus mode. Subsequent to the construction tests were performed on devices PF-400J (T /4 = 300ns, C = 880nF, L = 38nH, E = 400J, lo = 168kA) y PF-2kJ (device between the hundreds of joules and kilojoules of energy) diagnostic charged particle emission used the Faraday Cup consisting of a biased graphite collector. For a series of shots on the PF-400J and PF-2kJ operated at 27kV and 20kV respectively kinetic energy distribution of proton between 60keV-150keV were found, deuterons between 60KeV-300KeV. With the idea of optimizing the results in future diagnostic type spectrometer Thompson, spectroscopy and diffraction networks in gas mixture will be implemented

  4. A 3-MA compact-toroid-plasma-flow-switched plasma focus demonstration experiment on Shiva Star

    Energy Technology Data Exchange (ETDEWEB)

    Kiuttu, G F; Degnan, J H [Phillips Lab., Kirtland AFB, NM (United States). High Energy Sources Div.; Graham, J D [Maxwell Labs., Albuquerque, NM (United States); and others

    1997-12-31

    A novel dense plasma focus experiment using the Shiva Star capacitor bank is described. The experiment uses a compact toroid (CT) magnetized plasma flow switch (PFS) to initiate the focus implosion. The CT armature stably and reproducibly translates up to 3 MA from the vacuum feed region through coaxial electrodes to the gas puff central load. The inertia of the 1 mg CT and the work that must be done in compressing the internal magnetic fields during the translation provide a delay in current delivery to the pinch of 5 - 10 {mu}s, which matches the bank quarter cycle time relatively well. Effectiveness of the current delivery was monitored primarily by inductive probes in the PFS region, fast photography of the focus, and x-ray and neutron measurements of the pinch. K shell x-ray yields using neon gas were as high as 1 kJ, and 10{sup 8} neutrons were produced in a deuterium gas focus. (author). 4 figs., 10 refs.

  5. A 3-MA compact-toroid-plasma-flow-switched plasma focus demonstration experiment on Shiva Star

    International Nuclear Information System (INIS)

    Kiuttu, G.F.; Degnan, J.H.

    1996-01-01

    A novel dense plasma focus experiment using the Shiva Star capacitor bank is described. The experiment uses a compact toroid (CT) magnetized plasma flow switch (PFS) to initiate the focus implosion. The CT armature stably and reproducibly translates up to 3 MA from the vacuum feed region through coaxial electrodes to the gas puff central load. The inertia of the 1 mg CT and the work that must be done in compressing the internal magnetic fields during the translation provide a delay in current delivery to the pinch of 5 - 10 μs, which matches the bank quarter cycle time relatively well. Effectiveness of the current delivery was monitored primarily by inductive probes in the PFS region, fast photography of the focus, and x-ray and neutron measurements of the pinch. K shell x-ray yields using neon gas were as high as 1 kJ, and 10 8 neutrons were produced in a deuterium gas focus. (author). 4 figs., 10 refs

  6. Plasma lens focusing and plasma channel transport for heavy ion fusion

    International Nuclear Information System (INIS)

    Tauschwitz, A.; Yu, S.S.; Bangerter, R.O.

    1996-01-01

    The final focus lens in an ion beam driven inertial confinement fusion reactor is important since it sets limiting requirements for the quality of the driver beam. Improvements of the focusing capabilities can facilitate the construction of the driver significantly. A focusing system that is of interest both for heavy ion and for light ion drivers is an adiabatic, current carrying plasma lens. This lens is characterized by the fact that it can slowly (adiabatically) reduce the envelope radius of a beam over several betatron oscillations by increasing the focusing magnetic field along a tapered high current discharge. A reduction of the beam diameter by a factor of 3 to 5 seems feasible with this focusing scheme. Such a lens can be used for an ignition test facility where it can be directly coupled to the fusion target. For use in a repetitively working reactor chamber the lens has to be located outside of the reactor and the tightly focused but strongly divergent beam must be confined in a high current transport channel from the end of the lens into the immediate vicinity of the target. Laser preionization of a background gas is an efficient means to direct and stabilize such a channel. Experiments have been started to test both, the principle of adiabatic focusing, and the stability of laser preionized high current discharge channels. (author). 4 figs., 7 refs

  7. Plasma lens focusing and plasma channel transport for heavy ion fusion

    Energy Technology Data Exchange (ETDEWEB)

    Tauschwitz, A; Yu, S S; Bangerter, R O [Lawrence Berkeley Lab., CA (United States); and others

    1997-12-31

    The final focus lens in an ion beam driven inertial confinement fusion reactor is important since it sets limiting requirements for the quality of the driver beam. Improvements of the focusing capabilities can facilitate the construction of the driver significantly. A focusing system that is of interest both for heavy ion and for light ion drivers is an adiabatic, current carrying plasma lens. This lens is characterized by the fact that it can slowly (adiabatically) reduce the envelope radius of a beam over several betatron oscillations by increasing the focusing magnetic field along a tapered high current discharge. A reduction of the beam diameter by a factor of 3 to 5 seems feasible with this focusing scheme. Such a lens can be used for an ignition test facility where it can be directly coupled to the fusion target. For use in a repetitively working reactor chamber the lens has to be located outside of the reactor and the tightly focused but strongly divergent beam must be confined in a high current transport channel from the end of the lens into the immediate vicinity of the target. Laser preionization of a background gas is an efficient means to direct and stabilize such a channel. Experiments have been started to test both, the principle of adiabatic focusing, and the stability of laser preionized high current discharge channels. (author). 4 figs., 7 refs.

  8. Investigation of plasma dynamics and x-ray emission in'ATON'plasma focus

    International Nuclear Information System (INIS)

    Soliman, H.M.; Masoud, M.M.

    1995-01-01

    The experimental studies on 20 kJ 'Aton' plasma focus device are presented in this paper. The plasma sheath structure has been investigated by means of the measurements of the axial and azimuthal magnetic fields along the coaxial electrodes. The operating gas was hydrogen with pressures in the range of 0.62 torr to 6 torr. The intensity of visible radiation emitted by the plasma sheath was measured as a function of axial distances along the coaxial electrodes. The results showed that the visible radiation intensity is increased with axial distances until a position near the muzzle, then it decreased and has a minimum value at the coaxial electrode muzzle. The main parameters contributing to the behavior of the distribution are the plasma sheath density and the impurities from the eroded materials of the discharge electrodes. An x-ray pulse has been detected along the coaxial electrodes and extended up to the expansion chamber. At a distance near the muzzle two x-ray pulses have been detected, the second one has intensity relative to the first one with time lag of 11μs. 8 fig

  9. Compressing and focusing a short laser pulse by a thin plasma lens

    International Nuclear Information System (INIS)

    Ren, C.; Duda, B. J.; Hemker, R. G.; Mori, W. B.; Katsouleas, T.; Antonsen, T. M.; Mora, P.

    2001-01-01

    We consider the possibility of using a thin plasma slab as an optical element to both focus and compress an intense laser pulse. By thin we mean that the focal length is larger than the lens thickness. We derive analytic formulas for the spot size and pulse length evolution of a short laser pulse propagating through a thin uniform plasma lens. The formulas are compared to simulation results from two types of particle-in-cell code. The simulations give a greater final spot size and a shorter focal length than the analytic formulas. The difference arises from spherical aberrations in the lens which lead to the generation of higher-order vacuum Gaussian modes. The simulations also show that Raman side scattering can develop. A thin lens experiment could provide unequivocal evidence of relativistic self-focusing

  10. Type 1 diabetes and obesity in children : Focus on inflammation

    NARCIS (Netherlands)

    Verrijn Stuart, A.A.

    2013-01-01

    Type 1 diabetes (T1D) is an inflammatory disorder as is obesity. This thesis addresses inflammatory features in both conditions, with focus on inflammatory mediators and the role of adipose tissue (AT). The first part, specific aspects of immune tolerance in T1D,focuses on immune (dys) regulation

  11. Polarization of X-ray lines emitted from plasma-focus discharges; Problems of interpretation

    International Nuclear Information System (INIS)

    Jakubowski, L.

    2002-01-01

    In high current pulse discharges of the Plasma Focus (PF) type, inside the collapsing pinch column, there are formed local micro-regions of high-density and high-temperature plasma, so-called hot spots. Individual hot spots are separated in space and time. Each hot spot is characterized by its specific electron concentration and temperature, as well as by the emission of X-ray lines with different polarization. When numerous hot spots are produced it is impossible to determine local plasma parameters and to interpret the polarization effects. To eliminate this problem this study was devoted to the realization of PF-type discharges with single hot spot only. It has been achieved by a choice of the electrode configuration, which facilitated the formation of a single hot spot emitting intense X-ray lines. At the chosen experimental conditions it was possible to determine local plasma parameters and to demonstrate evident differences in the polarization of the observed X-ray lines. (author)

  12. X-ray polarization studies of plasma focus experiments with a single hot spots

    International Nuclear Information System (INIS)

    Jakubowski, L.; Sadowski, M.J.; Baronova, E.O.

    2004-01-01

    In high current pulse discharges of the plasma focus (PF) type, inside the collapsing pinch column, there are formed local micro-regions of high-density and high-temperature plasma, so-called hot spots. Individual hot spots are separated in space and time. Each hot spot is characterized by its specific electron concentration and temperature, as well as by the emission of x-ray lines with different polarization. When numerous hot spots are produced it is impossible to determine local plasma parameters and to interpret the polarization effects. To eliminate this problem this study was devoted to the realization of PF-type discharges with single hot spot only. It has been achieved by a choice of the electrode configuration, which facilitated the formation of a single hot spot emitting intense x-ray lines. At the chosen experimental conditions it was possible to determine local plasma parameters and to demonstrate evident differences in the polarization of the observed x-ray lines. (author)

  13. Polarization of x-ray lines emitted from plasma-focus discharges; Problems of interpretation

    International Nuclear Information System (INIS)

    Jakubowski, L.; Sadowski, M.J.; Baronova, E.O.

    2003-01-01

    In high current pulse discharges of the Plasma Focus (PF) type, inside the collapsing pinch column, there are formed local micro-regions of high-density and high-temperature plasma, so-called hot spots. Individual hot spots are separated in space and time. Each hot spot is characterized by its specific electron concentration and temperature, as well as by the emission of X-ray lines with different polarization. When numerous hot spots are produced it is impossible to determine local plasma parameters and to interpretate the polarization effects. To eliminate this problem this study was devoted to the realization of PF-type discharges with single hot spot only. It has been achieved by a choice of the electrode configuration, which facilitated the formation of a single hot spot emitting intense X-ray lines. At the chosen experimental conditions it was possible to determine local plasma parameters and to demonstrate evident differences in the polarization of the observed X-ray lines. (author)

  14. Electromagnetic field theory. Solely theories with plasma in focus

    International Nuclear Information System (INIS)

    Stenstrom, L.

    1979-01-01

    The Institute of Electromagnetic Field Theory at Chalmers Technical University is concerned with purely theoretical work on plasma physics for nuclear fusion. The team concerned is looking at nonlinear effects in the plasma energy exchange mechanism. Both inertia restricted and magnetically enclosed plasma are considered. Analytic and computer methods are used upon the model equations of the plasma. The Institute has associations with Euratom and with work in Maryland and in Grenoble. Work on particle paths is of interst. It also is associated with the construction at Sundsvik of an accelerator to give zero keV negative ions. A problem is to find staff of a sufficiently high quality for such complex work. The difficulties are not economic, but mainly that the desired practical results appear to be so far into the future. (G.P.)

  15. Potential medical applications of the plasma focus in the radioisotope production for PET imaging

    International Nuclear Information System (INIS)

    Roshan, M.V.; Razaghi, S.; Asghari, F.; Rawat, R.S.; Springham, S.V.; Lee, P.; Lee, S.; Tan, T.L.

    2014-01-01

    Devices other than the accelerators are desired to be investigated for generating high energy particles to induce nuclear reaction and positron emission tomography (PET) producing radioisotopes. The experimental data of plasma focus devices (PF) are studied and the activity scaling law for External Solid Target (EST) activation is established. Based on the scaling law and the techniques to enhance the radioisotopes production, the feasibility of generating the required activity for PET imaging is studied. - Highlights: • Short lived radioisotopes for PET imaging are produced in plasma focus device. • The scaling law of the activity induced with plasma focus energy is established. • The potential medical applications of plasma focus are studied

  16. Comparison the Results of Numerical Simulation And Experimental Results for Amirkabir Plasma Focus Facility

    Science.gov (United States)

    Goudarzi, Shervin; Amrollahi, R.; Niknam Sharak, M.

    2014-06-01

    In this paper the results of the numerical simulation for Amirkabir Mather-type Plasma Focus Facility (16 kV, 36μF and 115 nH) in several experiments with Argon as working gas at different working conditions (different discharge voltages and gas pressures) have been presented and compared with the experimental results. Two different models have been used for simulation: five-phase model of Lee and lumped parameter model of Gonzalez. It is seen that the results (optimum pressures and current signals) of the Lee model at different working conditions show better agreement than lumped parameter model with experimental values.

  17. Comparison the results of numerical simulation and experimental results for Amirkabir plasma focus facility

    International Nuclear Information System (INIS)

    Goudarzi, Shervin; Amrollahi, R; Sharak, M Niknam

    2014-01-01

    In this paper the results of the numerical simulation for Amirkabir Mather-type Plasma Focus Facility (16 kV, 36μF and 115 nH) in several experiments with Argon as working gas at different working conditions (different discharge voltages and gas pressures) have been presented and compared with the experimental results. Two different models have been used for simulation: five-phase model of Lee and lumped parameter model of Gonzalez. It is seen that the results (optimum pressures and current signals) of the Lee model at different working conditions show better agreement than lumped parameter model with experimental values.

  18. Design of a new type synchronous focusing mechanism

    Science.gov (United States)

    Zhang, Jintao; Tan, Ruijun; Chen, Zhou; Zhang, Yongqi; Fu, Panlong; Qu, Yachen

    2018-05-01

    Aiming at the dual channel telescopic imaging system composed of infrared imaging system, low-light-level imaging system and image fusion module, In the fusion of low-light-level images and infrared images, it is obvious that using clear source images is easier to obtain high definition fused images. When the target is imaged at 15m to infinity, focusing is needed to ensure the imaging quality of the dual channel imaging system; therefore, a new type of synchronous focusing mechanism is designed. The synchronous focusing mechanism realizes the focusing function through the synchronous translational imaging devices, mainly including the structure of the screw rod nut, the shaft hole coordination structure and the spring steel ball eliminating clearance structure, etc. Starting from the synchronous focusing function of two imaging devices, the structure characteristics of the synchronous focusing mechanism are introduced in detail, and the focusing range is analyzed. The experimental results show that the synchronous focusing mechanism has the advantages of ingenious design, high focusing accuracy and stable and reliable operation.

  19. Spectral study of the electron beam emitted from a 3 kJ plasma focus

    International Nuclear Information System (INIS)

    Patran, A; Tan, L C; Stoenescu, D; Rafique, M S; Rawat, R S; Springham, S V; Tan, T L; Lee, P; Zakaullah, M; Lee, S

    2005-01-01

    In a 3 kJ Mather-type plasma focus device operated in neon, the electron beam emission is investigated using both a magnetic electron energy analyser (in the 30-660 keV range) and a Rogowski coil (coupled with an appropriate RC passive integrator). Several electron emission features are identified and correlated with the x-ray emission in different energy ranges. The electron beam output shows very strong correlation with the general plasma dynamics (breakdown, axial and radial acceleration, pinch and post-pinch phases). The electrons' energy spectra showed most of the electron emission concentrating below 200 keV and negligible emission with energy above 350 keV. At 4 mbar neon, the electron emission, as well as the beam energy, is the highest and has a good shot-to-shot reproducibility

  20. An electrodynamical model for the ion behaviour in the final plasma focus stages

    International Nuclear Information System (INIS)

    Zambreanu, V.; Doloc, C.M.

    1992-01-01

    Plasma focus devices (PFDs) are strong sources of fusion neutrons but the problem of which interactions are responsible for the fusion reactions is still open since neither of the proposed theoretical models has been confirmed experimentally. A model for the trajectories of the deuteron ions in a configuration of selfconsistent electromagnetic fields is proposed starting from an empirical plasma model which describes the plasma focus collapse and column phases. The proposed model is only electrodynamical under the assumption of a uniform current density and an infinite length of the plasma column, not taking into account the fluid characteristics of the plasma. (author)

  1. Soft X-ray measurements for investigating the plasma focus dynamics

    International Nuclear Information System (INIS)

    Nahrath, B.

    In a Mather-type plasma focus short time soft x-ray pictures are taken by means of a double pinhole camera equipped with a pulsed channel plate and two different filters to study the local development of electron temperatures Tsub(e) with time resolution of 3 ns. Up to the maximum compression the measured Tsub(e) are roughly in accordance with the results of MHD-calculations. During a later phase, characterized by the occurence of m=O-instabilities, localized plasma regions with high densities and high electron temperatures Tsub(e) of about 600 eV (up to 1000 eV) are observed. Using the channel plate technique with increased sensivity a slowly decaying plasma with local Tsub(e)-values of about 300 eV and large diffuse structures is identified for several hundred nanoseconds. During this 'late phase' of the focus most of the neutron emission takes place. There is no correlation between the value of Tsub(e) and the rate of neutron emission. (orig.) [de

  2. Investigation of focusing of relativistic electron and positron bunches moving in cold plasma. Final report

    International Nuclear Information System (INIS)

    Amatuni, A.Ts.; Elbakian, S.S.; Khachatryan, A.G.; Sekhpossian, E.V.

    1995-03-01

    This document is the final report on a project to study focusing effects of relativistic beams of electrons and positrons interacting with a cold plasma. The authors consider three different models for the overdense cold plasma - electron bunch interaction. They look at coulomb effects, wakefield effects, bunch parameters, and the effects of trains of pulses on focusing properties

  3. Deposition of titanium nitride on Si(1 0 0) wafers using plasma focus

    International Nuclear Information System (INIS)

    Hussain, Tousif; Ahmad, R.; Khan, I.A.; Siddiqui, Jamil; Khalid, Nida; Bhatti, Arshad Saleem; Naseem, Shahzad

    2009-01-01

    Titanium nitride thin films were deposited on Si(1 0 0) substrates by using a low energy (2.3 KJ) Mather-type plasma focus device. The composition of the deposited films was characterized by X-ray diffraction (XRD). The crystallite size has strong dependence on the numbers of focus shots. The crystallinity of TiN thin films is found to increase with increasing the number of focus shots. The effect of different number of focus shots on micro structural changes of thin films was characterized by Scanning Electron Microscope (SEM) and Atomic Force Microscope (AFM). SEM results showed net-like structure for film deposited for 15 numbers of shots, which are elongated grains of Si 3 N 4 in amorphous form embedded into TiN crystals. The average surface roughness was calculated from AFM images of the thin films. These results indicated that the average surface roughness increased for films deposited with increased number of focus shots. The least crystallite size and roughness are observed for film deposited with 25 focus shots.

  4. Observation of helical structure in a low energy plasma focus pinch

    International Nuclear Information System (INIS)

    Rout, R.K.; Shyam, A.

    1989-01-01

    Helical structure and hot spots were observed in a Mather-type plasma focus operated at 3 KJ of bank energy. The experiments were carried out with the help of a fast optical framing camera and two X-ray pin-hole cameras with different filters. It was observed that initially a conical pinch (with base diameter of 6 mm and length of 14 mm) with temperature of ≅ 10 2 eV was formed. This pinch disintegrated after ≅ 50 ns by a single lobe sausage instability into a central high temperature (≅ 10 3 eV) filament of 1 mm diameter and 8 mm length containing a high emissivity helical structure. This helix is probably responsible for generation of axial magnetic field and relaxation of the focus pinch. Hot spots of high X-ray intensity and temperature (≅ 10 3 eV) were also observed much beyond the filament region. (author)

  5. Stationary self-focusing of Gaussian laser beam in relativistic thermal quantum plasma

    International Nuclear Information System (INIS)

    Patil, S. D.; Takale, M. V.

    2013-01-01

    In the present paper, we have employed the quantum dielectric response in thermal quantum plasma to model relativistic self-focusing of Gaussian laser beam in a plasma. We have presented an extensive parametric investigation of the dependence of beam-width parameter on distance of propagation in relativistic thermal quantum plasma. We have studied the role of Fermi temperature in the phenomenon of self-focusing. It is found that the quantum effects cause much higher oscillations of beam-width parameter and better relativistic focusing of laser beam in thermal quantum plasma in comparison with that in the relativistic cold quantum plasma and classical relativistic plasma. Our computations show more reliable results in comparison to the previous works

  6. effect of the plasma ion channel on self-focusing of a Gaussian laser pulse in underdense plasma

    Directory of Open Access Journals (Sweden)

    Sh Irani

    2013-09-01

    Full Text Available  We have considered the self-focusing of a Gaussian laser pulse in unmagnetized plasma. High-intensity electromagnetic fields cause the variation of electron density in plasma. These changes in the special conditions cause the acceleration of electrons to the higher energy and velocities. Thus the equation of plasma density evolution was obtained considering the electrons ponderomotive force. Then, an equation for the width of laser pulse with a relativistic mass correction term and the effect of ion channel were derived and the propagation of high-intensity laser pulse in an underdense plasma with weak relativistic approximation was investigated. It is shown that the ratio of ion channel radius to spot size could result in different forms of self focusing for the laser pulse in plasma.

  7. Palm top plasma focus device as a portable pulsed neutron source

    International Nuclear Information System (INIS)

    Rout, R. K.; Niranjan, Ram; Srivastava, R.; Rawool, A. M.; Kaushik, T. C.; Gupta, Satish C.; Mishra, P.

    2013-01-01

    Development of a palm top plasma focus device generating (5.2 ± 0.8) × 10 4 neutrons/pulse into 4π steradians with a pulse width of 15 ± 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 μF capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of −15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 μF, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of 3 He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

  8. Beam deviation method as a diagnostic tool for the plasma focus

    International Nuclear Information System (INIS)

    Schmidt, H.; Rueckle, B.

    1978-01-01

    The application of an optical method for density measurements in cylindrical plasmas is described. The angular deviation of a probing light beam sent through the plasma is proportional to the maximum of the density in the plasma column. The deviation does not depend on the plasma dimensions, however, it is influenced to a certain degree by the density profile. The method is successfully applied to the investigation of a dense plasma focus with a time resolution of 2 ns and a spatial resolution (in axial direction) of 2 mm. (orig.) [de

  9. Dense Plasma Focus-Based Nanofabrication of III-V Semiconductors: Unique Features and Recent Advances.

    Science.gov (United States)

    Mangla, Onkar; Roy, Savita; Ostrikov, Kostya Ken

    2015-12-29

    The hot and dense plasma formed in modified dense plasma focus (DPF) device has been used worldwide for the nanofabrication of several materials. In this paper, we summarize the fabrication of III-V semiconductor nanostructures using the high fluence material ions produced by hot, dense and extremely non-equilibrium plasma generated in a modified DPF device. In addition, we present the recent results on the fabrication of porous nano-gallium arsenide (GaAs). The details of morphological, structural and optical properties of the fabricated nano-GaAs are provided. The effect of rapid thermal annealing on the above properties of porous nano-GaAs is studied. The study reveals that it is possible to tailor the size of pores with annealing temperature. The optical properties of these porous nano-GaAs also confirm the possibility to tailor the pore sizes upon annealing. Possible applications of the fabricated and subsequently annealed porous nano-GaAs in transmission-type photo-cathodes and visible optoelectronic devices are discussed. These results suggest that the modified DPF is an effective tool for nanofabrication of continuous and porous III-V semiconductor nanomaterials. Further opportunities for using the modified DPF device for the fabrication of novel nanostructures are discussed as well.

  10. Plasma follistatin is elevated in patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Hansen, J; Rinnov, Anders Rasmussen; Krogh-Madsen, Rikke

    2013-01-01

    Plasma follistatin is elevated in patients with low-grade inflammation and insulin resistance as observed with polycystic ovary syndrome. In the present study, we evaluated plasma follistatin in patients with type 2 diabetes characterised by low-grade inflammation and assessed the acute effects o...... of hyperglycemia, hyperinsulinemia and LPS on plasma follistatin....

  11. Plasma apolipoprotein A5 and triglycerides in type 2 diabetes

    NARCIS (Netherlands)

    Dallinga-Thie, G. M.; van Tol, A.; Hattori, H.; van Vark-van der Zee, L. C.; Jansen, H.; Sijbrands, E. J. G.

    2006-01-01

    Variation in the human apolipoprotein (APO) A5 gene (APOA5) is associated with elevated plasma triglycerides. However, data on the exact role of plasma concentrations of APOA5 in human triglyceride homeostasis are lacking. In the present study, we estimated plasma APOA5 levels in patients with type

  12. Ion implantation on nickel targets by means of repetitive plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Vitulli, S.; Rapezzi, L. [ENEA Brasimone, Camugnano, Bologna (Italy); Apicella, M.L.; Samuelli, M. [ENEA Frascati, Frascati, Roma (Italy)

    2004-07-01

    Some test has been done in order to assess the possible use of a plasma focus as an implanter. The device utilized is the repetitive Plasma Focus operating in the ENEA Brasimone Center. The implanted sample is a sheet of Nickel with a surface of 17 cm{sup 2} inserted in a rigid sample at a variable distance from the top of the anode. After irradiation the sample is analyzed with Auger spectroscopy that provides the surface concentration of the various elements on the sample at different implantation depths. The result of the analysis shows that the Plasma Focus is an effective implantation source, even for metallurgical applications. (orig.)

  13. Hard X-ray sources from miniature plasma focus devices

    International Nuclear Information System (INIS)

    Raspa, V.; Silva, P.; Moreno, J.; Zambra, M.; Soto, L.

    2004-01-01

    As first stage of a program to design a repetitive pulsed radiation generator for industrial applications, two miniature plasma foci have been designed and constructed at the Chilean commission of nuclear energy. The devices operate at an energy level of the order of tens of joules (PF-50 J, 160 nF capacitor bank, 20-35 kV, 32-100 J, ∼ 150 ns time to peak current) and hundred of joules (PF-400 J, 880 nF, 20-35 kV, 176-539 J, ∼ 300 ns time to peak current). Hard X-rays are being studied in these devices operating with hydrogen. Images of metallic plates with different thickness were obtained on commercial radiographic film, Agfa Curix ST-G2, in order to characterize the energy of the hard X-ray outside of the discharge chamber of PF-400 J. An effective energy of the order of 90 keV was measured under those conditions. X ray images of different metallic objects also have been obtained. (authors)

  14. Hard X-ray sources from miniature plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Raspa, V. [Buenos Aires Univ., PLADEMA, CONICET and INFIP (Argentina); Silva, P.; Moreno, J.; Zambra, M.; Soto, L. [Comision Chilena de Energia Nuclear, Santiago (Chile)

    2004-07-01

    As first stage of a program to design a repetitive pulsed radiation generator for industrial applications, two miniature plasma foci have been designed and constructed at the Chilean commission of nuclear energy. The devices operate at an energy level of the order of tens of joules (PF-50 J, 160 nF capacitor bank, 20-35 kV, 32-100 J, {approx} 150 ns time to peak current) and hundred of joules (PF-400 J, 880 nF, 20-35 kV, 176-539 J, {approx} 300 ns time to peak current). Hard X-rays are being studied in these devices operating with hydrogen. Images of metallic plates with different thickness were obtained on commercial radiographic film, Agfa Curix ST-G2, in order to characterize the energy of the hard X-ray outside of the discharge chamber of PF-400 J. An effective energy of the order of 90 keV was measured under those conditions. X ray images of different metallic objects also have been obtained. (authors)

  15. Strong self-focusing of a cosh-Gaussian laser beam in collisionless magneto-plasma under plasma density ramp

    International Nuclear Information System (INIS)

    Nanda, Vikas; Kant, Niti

    2014-01-01

    The effect of plasma density ramp on self-focusing of cosh-Gaussian laser beam considering ponderomotive nonlinearity is analyzed using WKB and paraxial approximation. It is noticed that cosh-Gaussian laser beam focused earlier than Gaussian beam. The focusing and de-focusing nature of the cosh-Gaussian laser beam with decentered parameter, intensity parameter, magnetic field, and relative density parameter has been studied and strong self-focusing is reported. It is investigated that decentered parameter “b” plays a significant role for the self-focusing of the laser beam as for b=2.12, strong self-focusing is seen. Further, it is observed that extraordinary mode is more prominent toward self-focusing rather than ordinary mode of propagation. For b=2.12, with the increase in the value of magnetic field self-focusing effect, in case of extraordinary mode, becomes very strong under plasma density ramp. Present study may be very useful in the applications like the generation of inertial fusion energy driven by lasers, laser driven accelerators, and x-ray lasers. Moreover, plasma density ramp plays a vital role to enhance the self-focusing effect

  16. Strong self-focusing of a cosh-Gaussian laser beam in collisionless magneto-plasma under plasma density ramp

    Energy Technology Data Exchange (ETDEWEB)

    Nanda, Vikas; Kant, Niti, E-mail: nitikant@yahoo.com [Department of Physics, Lovely Professional University, G. T. Road, Phagwara, Punjab 144411 (India)

    2014-07-15

    The effect of plasma density ramp on self-focusing of cosh-Gaussian laser beam considering ponderomotive nonlinearity is analyzed using WKB and paraxial approximation. It is noticed that cosh-Gaussian laser beam focused earlier than Gaussian beam. The focusing and de-focusing nature of the cosh-Gaussian laser beam with decentered parameter, intensity parameter, magnetic field, and relative density parameter has been studied and strong self-focusing is reported. It is investigated that decentered parameter “b” plays a significant role for the self-focusing of the laser beam as for b=2.12, strong self-focusing is seen. Further, it is observed that extraordinary mode is more prominent toward self-focusing rather than ordinary mode of propagation. For b=2.12, with the increase in the value of magnetic field self-focusing effect, in case of extraordinary mode, becomes very strong under plasma density ramp. Present study may be very useful in the applications like the generation of inertial fusion energy driven by lasers, laser driven accelerators, and x-ray lasers. Moreover, plasma density ramp plays a vital role to enhance the self-focusing effect.

  17. Energy transformation in Z-pinch and plasma focus discharges with wire and wire-in-liner loads

    International Nuclear Information System (INIS)

    Kubes, Pavel; Kravarik, Jozef; Klir, Daniel; Scholz, Marek; Paduch, Marian; Tomaszewski, Krzysztof; Karpinski, Leslaw; Bakshaev, Yury L.; Blinov, Peter I.; Chernenko, Andrey S.; Dan'ko, Sergey A.; Korolev, Valery D.; Shashkov, Andrey Y.; Tumanov, Victor I.

    2002-01-01

    The results of the study of the Z-pinch and plasma-focus plasmas at presence of the axial C, Al, or Cu wires of sufficient high diameter are discussed in this paper. The wire was positioned on the top of the inner electrode of the PF 1000 plasma focus (1.8 MA, IPPLM Warsaw), or at the axis with or without the tungsten or alumine wire array load at the S-300 facility (3 MA, RRC Kurchatov Institute, Moscow), and at the axis of the small Z-pinch Z-150 (50 kA, CTU Prague). The plasma corona around the wire was generated both by the current going through the wires and by the implosion of the wire array or of the current sheath. The experiments showed interesting results often observed in some shots of Z-pinch type discharges - existence of helical structures, two relatively long and stable pinch phases, oscillation of pinch diameter, and back return of the plasma exploding from the pinch. All these observed phenomena can be evolved by spontaneous self-generation and transformation of the axial magnetic field in the pinch during the plasma implosion and explosion. A configuration of axial and azimuthal magnetic field confines the plasma and later transforms or dissipates during a few tens or hundreds ns. A fast transformation of internal magnetic fields can induce a sufficiently high electric field for generation of keV particles and radiation. Study and usage of Z-pinch discharges is connected with solving of two principal problems, limitation of instability development and a way of generation of high energy particles and radiation. The first problem is partially solved by the faster increase of the current, by better cylindrical symmetry of the load and plasma, by higher density of the plasma or by the presence of a stronger magnetized plasma

  18. Evaluation of the effect of anode groove pitch to ion beam focusibility on spherical plasma focus diode

    Energy Technology Data Exchange (ETDEWEB)

    Imanari, K [Oyama National College of Technology (Japan). Department of Electrical Engineering; Jiang, W; Masugata, K; Yatsui, K [Nagaoka Univ. of Technology (Japan). Laboratory of Beam Technology

    1997-12-31

    A new PIC simulation code was developed to evaluate the effect of anode plasma nonuniformity on LIB focusibility. The plasma nonuniformity was modelled by inducing anode grooves in the code. In the experimental conditions, groove pitch about 2.2 mm and groove width of 1.0 mm, the simulation results are in a good agreement with the observed data. At a groove pitch of 2.4 mm, the local divergence was very small, although the focal length was very long. It was inferred that the focusibility of SPFD will be determined by the z-deflection angle rather than the local divergence angle. Modification of the anode curvature may be advantageous to get a higher power density on the focal point. (author). 6 figs., 3 refs.

  19. Basic physical phenomena, neutron production and scaling of the dense plasma focus

    International Nuclear Information System (INIS)

    Kaeppeler, H.J.

    This paper presents an attempt at establishing a model theory for the dense plasma focus in order to present a consistent interpretation of the basic physical phenomena leading to neutron production from both acceleration and thermal processes. To achieve this, the temporal history of the focus is divided into the compression of the plasma sheath, a qiescent and very dense phase with ensuing expansion, and an instable phase where the focus plasma is disrupted by instabilities. Finally, the decay of density, velocity and thermal fields is considered. Under the assumption that Io 2 /sigmaoRo 2 = const and to/Tc = const, scaling laws for plasma focus devices are derived. It is shown that while generally the neutron yield scales with the fourth power of maximum current, neutron production from thermal processes becomes increasingly important for large devices, while in the small devices neutron production from acceleration processes is by far predominant. (orig.) [de

  20. Plasma-focus neutron diagnostics by means of high-sensitivity bubble detectors

    International Nuclear Information System (INIS)

    Zoita, V.; Pantea, A.; Patran, A.; Lee, P.; Springham, S.V.; Koh, M.; Rawat, R.S.; Zhang, T.; Hassan, M.

    2005-01-01

    A new type of bubble detector (a superheated fluid detector), the DEFENDER TM , was tested as a neutron diagnostics device on the NX2 plasma focus (PF) device at the NIE/NTU, Singapore. The DEFENDER TM detector was recently developed and commercialised by BTI, Canada, and it is characterised by a very high sensitivity (a factor of about 30 higher than the standard detectors) to fast neutrons (energy above 100 keV). Together with its particular energy response this high sensitivity allows for the development of improved neutron diagnostics for the PF devices. The NX2 plasma focus device has the following typical operating parameters: condenser bank charging voltage: 15 kV; stored energy: 2.3 kJ; peak current: 420 kA; current rise-time: 1.35 μs; deuterium pressure: 20 mbar. During most of the experiments reported here the NX2 device was operated at 14 kV charging voltage and 20 mbar deuterium pressure. A few shots were done at voltages of 14.5 and 15 kV and the same gas pressure. The bubble detector neutron diagnostics experiments carried out on the NX2 machine involved the following measurements: 1. Relative calibration of the four detectors. The detectors were irradiated simultaneously, in identical conditions, by plasma focus neutron pulses and their neutron responses were compared.; 2. angular distribution of the neutron fluence (single shot). The distribution of the neutron fluence was measured at four angles with respect to the PF electrode axis: 0, 30, 60 and 90 deg; 3. Reproducibility of the neutron yield at high repetition rate operation. The NX2 device was operated at 1 Hz repetition rate.; 4. Bubble detector response time. The response time of the DEFENDER TM detector was tested by using the short PF neutron pulses and a high-speed video camera. The paper will present the results of these experiments and their implications for the development of neutron plasma diagnostics techniques based on the bubble detectors and their broader class of superheated

  1. Nuclear Malaysia Plasma Focus Device as a X-ray Source For Radiography Applications

    International Nuclear Information System (INIS)

    Rokiah Mohd Sabri; Abdul Halim Baijan; Siti Aiasah Hashim; Mohd Rizal Mohd Chulan; Wah, L.K.; Mukhlis Mokhtar; Azaman Ahmad; Rosli Che Ros

    2013-01-01

    A 3.375 kJ plasma focus is designed to operate at 13.5 kV for the purpose of studying x-ray source for radiography in Argon discharge. X-rays is detected by using x-ray film from the mammography radiographic plate. The feasibility of the plasma focus as a high intensity flash x-ray source for good contrast in radiography image is presented. (author)

  2. High Voltage Homemade Capacitor Charger for Plasma Focus System

    International Nuclear Information System (INIS)

    Abdul Halim Baijan; Azaman Ahmad; Rokiah Mohd Sabri; Siti Aiasah Hashim; Mohd Rizal Md Chulan; Wah, L.K.; Azhar Ahmad; Rosli Che Ros; Mohd Faiz Mohd Zin

    2015-01-01

    A high voltage capacitor charger has been designed and built to replace a high voltage charger type General Atomics CCDs Power Supply which was damaged. The fabrication design was using materials which were easily available in the local market. Among the main components of the high-voltage charger is a transformer for neon lights, variable transformer rated 0 - 240 V 1 KVA, and 240 V transformer isolator. The results of experiments that have been conducted shows that a homemade capacitor charger was able to charge high voltage capacitors up to the required voltage of which was 12 kV. However the time taken for charging is quite long, up to more than 6 minutes. (author)

  3. Characterization of plasma-induced cell membrane permeabilization: focus on OH radical distribution

    International Nuclear Information System (INIS)

    Sasaki, Shota; Honda, Ryosuke; Hokari, Yutaro; Takashima, Keisuke; Kaneko, Toshiro; Kanzaki, Makoto

    2016-01-01

    Non-equilibrium atmospheric-pressure plasma (APP) is used medically for plasma-induced cell permeabilization. However, how plasma irradiation specifically triggers permeabilization remains unclear. In an attempt to identify the dominant factor( s ), the distribution of plasma-produced reactive species was investigated, primarily focusing on OH radicals. A stronger plasma discharge, which produced more OH radicals in the gas phase, also produced more OH radicals in the liquid phase (OH aq ), enhancing the cell membrane permeability. In addition, plasma irradiation-induced enhancement of cell membrane permeability decreased markedly with increased solution thickness (<1 mm), and the plasma-produced OH aq decayed in solution (diffusion length on the order of several hundred micrometers). Furthermore, the horizontally center-localized distribution of OH aq corresponded with the distribution of the permeabilized cells by plasma irradiation, while the overall plasma-produced oxidizing species in solution (detected by iodine-starch reaction) exhibited a doughnut-shaped horizontal distribution. These results suggest that OH aq, among the plasma-produced oxidizing species, represents the dominant factor in plasma-induced cell permeabilization. These results enhance the current understanding of the mechanism of APP as a cell-permeabilization tool. (paper)

  4. Compact activation detectors for measuring of neutron emission on plasma focus installations

    International Nuclear Information System (INIS)

    Krokhin, O.N.; Nikulin, V.Ya.; Peregudova, E.V.; Volobuev, I.V.

    2005-01-01

    The paper presents the two compact simple systems for the measurement of the absolute neutron yield in the range 10 6 - 10 12 neutrons/pulse and higher and spatial anisotropy of neutron radiation. The systems are destined for the registration of the short duration neutron radiation of the pulsed plasma installations, such as Plasma Focus (PF), z-pinches and others plasma installations. This paper also includes the results of the neutron emission measurements on different PF installations: 'Tulip' (P.N. Lebedev Physical Institute, Moscow Russia), the PF-1000 and PF-150 installations (Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland)

  5. Measurement of angular distribution of neutrons emitted from plasma focus using NTD

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Maric, Z.; Banjanac, R.; Dragic, A.; Stanojevic, J.; Dordevic, D.; Joksimovic, D.; Udovicic, V.; Vukovic, J.

    1999-01-01

    Mica detectors together with thick uranium foils were used for detection and angular distribution measurement of the neutrons emitted from the d-plasma focus (DPF). The distance between detectors and plasma pinch was 4 cm. For reason of detector protection from the thermal shock, they were covered with the mica layer of 1 mm thickness. Annealing of the detectors were measured after the irradiation with neutrons from an Am-Be source and treated with thermal shock H-plasma focus (HPF). Geometry of detectors in both experiments was the same

  6. Measurement of angular distribution of neutrons emitted from plasma focus using NTD

    Energy Technology Data Exchange (ETDEWEB)

    Antanasijevic, R.; Maric, Z.; Banjanac, R.; Dragic, A.; Stanojevic, J.; Dordevic, D.; Joksimovic, D.; Udovicic, V.; Vukovic, J

    1999-06-01

    Mica detectors together with thick uranium foils were used for detection and angular distribution measurement of the neutrons emitted from the d-plasma focus (DPF). The distance between detectors and plasma pinch was 4 cm. For reason of detector protection from the thermal shock, they were covered with the mica layer of 1 mm thickness. Annealing of the detectors were measured after the irradiation with neutrons from an Am-Be source and treated with thermal shock H-plasma focus (HPF). Geometry of detectors in both experiments was the same.

  7. Measurement of angular distribution of neutrons emitted from plasma focus using NTD

    CERN Document Server

    Antanasijevic, R; Banjanac, R; Dragic, A; Stanojevic, J; Dordevic, D; Joksimovic, D; Udovicic, V; Vukovic, J

    1999-01-01

    Mica detectors together with thick uranium foils were used for detection and angular distribution measurement of the neutrons emitted from the d-plasma focus (DPF). The distance between detectors and plasma pinch was 4 cm. For reason of detector protection from the thermal shock, they were covered with the mica layer of 1 mm thickness. Annealing of the detectors were measured after the irradiation with neutrons from an Am-Be source and treated with thermal shock H-plasma focus (HPF). Geometry of detectors in both experiments was the same.

  8. Ti film deposition process of a plasma focus: Study by an experimental design

    Directory of Open Access Journals (Sweden)

    M. J. Inestrosa-Izurieta

    2017-10-01

    Full Text Available The plasma generated by plasma focus (PF devices have substantially different physical characteristics from another plasma, energetic ions and electrons, compared with conventional plasma devices used for plasma nanofabrication, offering new and unique opportunities in the processing and synthesis of Nanomaterials. This article presents the use of a plasma focus of tens of joules, PF-50J, for the deposition of materials sprayed from the anode by the plasma dynamics in the axial direction. This work focuses on the determination of the most significant effects of the technological parameters of the system on the obtained depositions through the use of a statistical experimental design. The results allow us to give a qualitative understanding of the Ti film deposition process in our PF device depending on four different events provoked by the plasma dynamics: i an electric erosion of the outer material of the anode; ii substrate ablation generating an interlayer; iii electron beam deposition of material from the center of the anode; iv heat load provoking clustering or even melting of the deposition surface.

  9. Transport of long-pulse relativistic electron beams in preformed plasma channels in the ion focus regime

    International Nuclear Information System (INIS)

    Miller, J.D.

    1989-01-01

    Experiments have been performed demonstrating efficient transport of long-pulse (380 ns), high-current (200 A), relativistic electron beams (REBs) in preformed plasma channels in the ion focus regime (IFR). Plasma channels were created by low-energy ( e , and channel ion mass, in agreement with theoretical values predicted for the ion hose instability. Microwave emission has also been observed indicative of REB-plasma electron two-stream instability. Plasma channel density measurements indicate that the two-stream instability can become dominant for measured f e values slightly above unity. The author has introduced a theoretical analysis for high-current REB transport and modulation in axially periodic IFR plasma channels. Analytic expression for the electric field are found for the case of a cosine modulation of the channel ion density. Two different types of channels are considered: (i) periodic beam-induced ionization channels, and (ii) periodic plasma slab channels created by an external source. Analytical conditions are derived for the matched radius of the electron beam and for approximate beam envelope motion using a 'smooth' approximation. Numerical solutions to the envelope equation show that by changing the wavelength or the amplitude of the space-charge neutralization fraction of the ion channel density modulation, the beam can be made to focus and diverge, or to undergo stable, modulated transport

  10. Neutron angular distribution in a plasma focus obtained using nuclear track detectors.

    Science.gov (United States)

    Castillo-Mejía, F; Herrera, J J E; Rangel, J; Golzarri, J I; Espinosa, G

    2002-01-01

    The dense plasma focus (DPF) is a coaxial plasma gun in which a high-density, high-temperature plasma is obtained in a focused column for a few nanoseconds. When the filling gas is deuterium, neutrons can be obtained from fusion reactions. These are partially due to a beam of deuterons which are accelerated against the background hot plasma by large electric fields originating from plasma instabilities. Due to a beam-target effect, the angular distribution of the neutron emission is anisotropic, peaked in the forward direction along the axis of the gun. The purpose of this work is to illustrate the use of CR-39 nuclear track detectors as a diagnostic tool in the determination of the time-integrated neutron angular distribution. For the case studied in this work, neutron emission is found to have a 70% contribution from isotropic radiation and a 30% contribution from anisotropic radiation.

  11. Effects of admixture gas on the production of {sup 18}F radioisotope in plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Talaei, Ahmad [Nuclear Science and Technology Research Institute (NSTR), Nuclear Science Research School, A.E.O.I., 14155-1339 Tehran (Iran, Islamic Republic of); Sadat Kiai, S.M., E-mail: sadatkiai@yahoo.co [Nuclear Science and Technology Research Institute (NSTR), Nuclear Science Research School, A.E.O.I., 14155-1339 Tehran (Iran, Islamic Republic of); Zaeem, A.A. [Department of Physics, Khaje Nasir University of Technology (K.N. Toosi), 1541846911 Tehran (Iran, Islamic Republic of)

    2010-12-15

    In this article, the effect of admixture gas on the heating and cooling of pinched plasma directly related to the enhancement or reduction of {sup 18}F production through the {sup 16}O({sup 3}He, p){sup 18}F is considered in the plasma focus devices. It is shown that by controlling the velocity of added Oxygen particles mixed with the working helium gas into the plasma focus chamber, one can increase the current and decrease the confinement time (plasma heating) or vice verse (plasma cooling). The highest level of nuclear activities of {sup 18}F was found around 16% of the Oxygen admixture participation and was about 0.35 MBq in the conditions of 20 kJ, 0.1 Hz and after 2 min operating of Dena PF. However, in the same condition, but for the frequency of 1 Hz, the level of activity increased up to 3.4 MBq.

  12. Experimental study of the performance of a very small repetitive plasma focus device in different working conditions

    Energy Technology Data Exchange (ETDEWEB)

    Goudarzi, S., E-mail: sgoudarzi@aeoi.org.ir; Babaee, H.; Esmaeli, A.; Nasiri, A. [Atomic Energy Organization of Iran, Plasma and Nuclear Fusion Research School, Nuclear Science and Technology Research Institute (Iran, Islamic Republic of)

    2017-01-15

    SORENA-1 is a very small repetitive Mather-type plasma focus device (20 J) that can operate at frequencies up to 1 Hz. This device has been designed and constructed in the Plasma and Nuclear Fusion Research School of the Nuclear Science and Technology Research Institute of Iran. In this article, the structure of SORENA-1 is described and results of experiments with Ar, Ne, and D{sub 2} working gases at several discharge voltages and initial pressures are presented and analyzed.

  13. The calculation of turbulence phenomena in plasma focus dynamics using REDUCE

    International Nuclear Information System (INIS)

    Hayd, A.; Maurer, M.; Meinke, P.; Kaeppeler, H.J.

    1982-05-01

    Based on previous calculations of the development of highly turbulent plasma states resulting from m=0 instabilities and the application to the turbulent development in the late stage of a plasma focus experiment, using REDUE, the treatment of plasma focus dynamics is extended to the compression stage and 'intermediate' stage between maximum density and m = o onset. For this, a two-fluid model of the magneto-fluid dynamic equations is employed. The non-linear development is again treated in ω, k-space and transformed back into r, t-space to obtain local dynamic variables as functions of time. The calculation is applied to the Stuttgart plasma focus experiment POSEIDON. It is shown that for relatively high pinch currents, neutron production also appears in the 'intermediate' phase, the life-time of which increases with increasing pinch current. (orig.)

  14. Characterization of a Very Small Plasma Focus in the Limit of Low Energy (50 J)

    International Nuclear Information System (INIS)

    Silva, P.; Sotol, L.; Moreno, J.; Sylvester, G.; Zambra, M.; Altamirano, L.; Bruzzone, H.; Clausse, A.; Moreno, C.

    2001-01-01

    A very small plasma focus device has been designed and constructed. The plasma focus operates in the limit of low energy (160 nF capacitor bank, 65 nH, 250-40 kV, ∼32-128 J). The design of the electrode was assisted by a simple model of a Mather plasma focus. The calculations indicate that yields of 10 4 -10 5 neutrons per shot are expected when the discharge is operated with deuterium. A single frame image converter camera (5 ns exposure) was used to obtain plasma images in the visible range. The umbrella-like current sheath running over the end of the coaxial electrodes and the pinch after the radial collapse can be clearly observed in the photographs. The observations are similar to the results obtained with devices operating at energies several order of magnitude higher. (author)

  15. Concrete shielding of neutron radiations of plasma focus and dose examination by FLUKA

    Science.gov (United States)

    Nemati, M. J.; Amrollahi, R.; Habibi, M.

    2013-07-01

    Plasma Focus (PF) is among those devices which are used in plasma investigations, but this device produces some dangerous radiations after each shot, which generate a hazardous area for the operators of this device; therefore, it is better for the operators to stay away as much as possible from the area, where plasma focus has been placed. In this paper FLUKA Monte Carlo simulation has been used to calculate radiations produced by a 4 kJ Amirkabir plasma focus device through different concrete shielding concepts with various thicknesses (square, labyrinth and cave concepts). The neutron yield of Amirkabir plasma focus at varying deuterium pressure (3-9 torr) and two charging voltages (11.5 and 13.5 kV) is (2.25 ± 0.2) × 108 neutrons/shot and (2.88 ± 0.29) × 108 neutrons/shot of 2.45 MeV, respectively. The most influential shield for the plasma focus device among these geometries is the labyrinth concept on four sides and the top with 20 cm concrete.

  16. Evidence of magnetic field in plasma focus by means of Faraday rotation measurements

    International Nuclear Information System (INIS)

    Fischfeld, G.

    1982-01-01

    Preliminary results of Faraday rotation measurements on a beam of laser light crossing the plasma column in the axial direction. are repacted. The presence of intense axial magnetic field Bsup(z) in the column both before and during the pinch phase is demonstrated. The experiments were performed on the Mather type Frascati 1 MJ plasma Focus, operated at 250 KJ 3 torr D 2 filling pressure. Is is used in the measurements a Quantel YG 49 YAG laser, frecuency doubled by means of KD*P crystal, which delivers about 60 mJ in 3 ns at = 530 nm. The beam polarization is analized by Wollaston prism. The electronic density is determined by Mach-Zender insterferometry. Two measurements are taken at time close to the end of the radial collapse phase, yielding Faraday rotation angles of 0.25 +- 0.05 rd and 0.56 +- o.05 rd which correspond to values, of axial magnetic fields of b(sup z) = 500 KG and B(sub z) = 400 KG. (Author) [pt

  17. Self-magnetically-insulated 'plasma-focus diode' as a new source of an intence pulsed light-ion beam

    International Nuclear Information System (INIS)

    Takahashi, Akira; Aga, Keigo; Masugata, Katsumi; Ito, Michiaki; Yatsui, Kiyoshi

    1986-01-01

    A new and simple type of self-magnetically-insulated diode named ''Plasma-Focus Diode'' has been successfully developed, where anode and cathode are constituted by a pair of coaxial cylindrical electrodes similarly to a Mather-type plasma-focus device. Operating conditions are typically as follows: inductively-calibrated diode voltage ∼ 660 kV, diode current ∼ 142 kA, total ion current ∼ 32 kA, pulse width ∼ 90 ns and diode efficiency ∼ 22 %. Multiple-shots operation more than 50 shots has been possible without changing flashboard. Local divergence angle has been observed to be 0.9 deg ∼ 1.6 deg. Using such a simple ion diode, we have demonstrated a possibility of high concentration of beam-power density onto a target placed at the center. (author)

  18. Duoplasmatron with a nozzle type plasma expension cup

    International Nuclear Information System (INIS)

    Kobayashi, M.; Nishikawa, T.; Takagi, A.

    1974-01-01

    Various tests are described which were carried out in order to clarify the cause of the aberration existing in the beams extracted from a nozzle type plasma expansion cup. The tests involve the extraction electrodes having different edge shapes, gridded extraction electrodes, high-voltage facing electrodes at the cup exit making different angles with the axis, plasma cups having different contours at the exit, plasma cups gridded at the exit, biasing the cup exit with respect to anode, plasma cups having different ratios of the exit area to axial length, etc. The results show that the inward meniscus type distortion of the plasma boundary near the rim of plasma cup will be a dominant source for the aberration. Both proper shaping of the contour of the cup exit and biasing the cup exit reduced the aberration

  19. Dynamics of ponderomotive self-focusing and periodic bursts of stimulated Brillouin backscattering in plasmas

    International Nuclear Information System (INIS)

    Andreev, N.E.; Gorbunov, L.M.; Tarakanov, S.V.; Zykov, A.I.

    1993-01-01

    The space--time evolution of ponderomotive self-focusing of electromagnetic beams in a plasma is investigated. The quasineutral, hydrodynamic plasma response to the ponderomotive force is considered. The set of coupled quasioptic and acoustic equations is solved both analytically and numerically for slab and cylindrical beams. It is shown that the transient process of self-focusing has the form of a nonlinear wave propagating along the beam axis from boundary into the interior of a plasma with velocity considerably higher than the ion-sound velocity. Mutual dynamics of self-focusing and stimulated Brillouin backscattering (SBBS) is computed. It is shown that self-focusing results in the high intensity periodical bursts of SBBS. However, the time average level of scattered radiation is quite low

  20. Formation of plasma channels in air under filamentation of focused ultrashort laser pulses

    International Nuclear Information System (INIS)

    Ionin, A A; Seleznev, L V; Sunchugasheva, E S

    2015-01-01

    The formation of plasma channels in air under filamentation of focused ultrashort laser pulses was experimentally and theoretically studied together with theoreticians of the Moscow State University and the Institute of Atmospheric Optics. The influence of various characteristics of ultrashort laser pulses on these plasma channels is discussed. Plasma channels formed under filamentation of focused laser beams with a wavefront distorted by spherical aberration (introduced by adaptive optics) and by astigmatism, with cross-section spatially formed by various diaphragms and with different UV and IR wavelengths, were experimentally and numerically studied. The influence of plasma channels created by a filament of a focused UV or IR femtosecond laser pulse (λ = 248 nm or 740 nm) on characteristics of other plasma channels formed by a femtosecond pulse at the same wavelength following the first one with varied nanosecond time delay was also experimentally studied. An application of plasma channels formed due to the filamentation of focused UV ultrashort laser pulses including a train of such pulses and a combination of ultrashort and long (∼100 ns) laser pulses for triggering and guiding long (∼1 m) electric discharges is discussed. (topical review)

  1. Self-focusing and guiding of short laser pulses in ionizing gases and plasmas

    International Nuclear Information System (INIS)

    Esarey, E.; Sprangle, P.; Krall, J.; Ting, A.

    1997-01-01

    The propagation of intense laser pulses in gases and plasmas is relevant to a wide range of applications, including laser-driven accelerators, laser-plasma channeling, harmonic generation, supercontinuum generation, X-ray lasers, and laser-fusion schemes. Here, several features of intense, short-pulse (≤1 ps) laser propagation in gases undergoing ionization and in plasmas are reviewed, discussed, and analyzed. The wave equations for laser pulse propagation in a gas undergoing ionization and in a plasma are derived. The source-dependent expansion method is discussed, which is a general method for solving the paraxial wave equation with nonlinear source terms. In gases, the propagation of high-power (near the critical power) laser pulses is considered including the effects of diffraction, nonlinear self-focusing, ionization, and plasma generation. Self-guided solutions and the stability of these solutions are discussed. In plasmas, optical guiding by relativistic effects, ponderomotive effects, and preformed density channels is considered. The self-consistent plasma response is discussed, including plasma wave effects and instabilities such as self-modulation. Recent experiments on the guiding of laser pulses in gases and in plasmas are briefly summarized

  2. Self-focusing and Raman scattering of laser pulses in tenuous plasmas

    International Nuclear Information System (INIS)

    Antonsen, T.M. Jr.; Mora, P.

    1993-01-01

    The propagation and self-focusing of short, intense laser pulses in a tenuous plasma is studied both analytically and numerically. Specifically, pulses of length of the order of a few plasma wavelengths and of intensity, which is large enough for relativistic self-focusing to occur, are considered. Such pulses are of interest in various laser plasma acceleration schemes. It is found that these pulses are likely to be strongly affected by Raman instabilities. Two different regimes of instability, corresponding to large and small scattering angles, are found to be important. Small-angle scattering is perhaps the most severe since it couples strongly with relativistic self-focusing, leading the pulses to acquire significant axial and transverse structure in a time of the order of the self-focusing time. Thus it will be difficult to propagate smooth self-focused pulses through tenuous plasmas for distances longer than the Rayleigh length, except for pulse duration of the order of the plasma period

  3. Current sheath curvature correlation with the neon soft x-ray emission from plasma focus device

    International Nuclear Information System (INIS)

    Zhang, T; Lin, X; Chandra, K A; Tan, T L; Springham, S V; Patran, A; Lee, P; Lee, S; Rawat, R S

    2005-01-01

    The insulator sleeve length is one of the major parameters that can severely affect the neon soft x-ray yield from a plasma focus. The effect of the insulation sleeve length on various characteristic timings of plasma focus discharges and hence the soft x-ray emission characteristics has been investigated using a resistive divider. The pinhole images and laser shadowgraphy are used to explain the observed variation in the average soft x-ray yield (measured using a diode x-ray spectrometer) with variation of the insulator sleeve length. We have found that for a neon filled plasma focus device the change in insulator sleeve length changes the current sheath curvature angle and thus the length of the focused plasma column. The optimized current sheath curvature angle is found to be between 39 0 and 41 0 , at the specific axial position of 6.2-9.3 cm from the cathode support plate, for our 3.3 kJ plasma focus device. A strong dependence of the neon soft x-ray yield on the current sheath curvature angle has thus been reported

  4. Diagnostic systems for the nuclear fusion and plasma research in the PF-24 plasma focus laboratory at the IFJ PAN

    Directory of Open Access Journals (Sweden)

    Marciniak Łukasz

    2016-12-01

    Full Text Available This paper presents a set of diagnostics dedicated to PF-24 - new medium size - plasma focus (PF device built and operated at the Institute of Nuclear Physics Polish Academy of Sciences (IFJ PAN. The PF-24 can operate at energy level up to 93 kJ and charging voltage up to 40 kV. Each condenser is connected with a specially designed spark gap with a very small jitter, which ensures a high effi ciency and a low current rise time. The working parameters of PF-24 generator make it a suitable tool for testing new detection systems to be used in fusion research. Four types of such detection systems are presented in this article: three diagnostic systems used to measure electric quantities (Rogowski coil, magnetic probe, capacitance probe, neutron counter based on beryllium activation, fast neutron pinhole camera based on small-area BCF-12 plastic scintillation detectors and high-speed four-frame soft X-ray camera with microchannel plate.

  5. Computer simulation of a plasma focus device driven by a magnetic pulser

    Energy Technology Data Exchange (ETDEWEB)

    Georgescu, N; Zoita, V [Inst. of Physics and Technology of Radiation Devices, Bucharest (Romania); Larour, J [Ecole Polytechnique, Palaiseau (France). Lab. de Physique des Milieux Ionises

    1997-12-31

    A plasma focus device, driven by a magnetic pulse compression circuit, is simulated by using a PSPICE proffam. The elaborated program is much simpler than the other existing ones, which analyse the circuit by directly solving a system of integral-differential equations. The pre-pulse voltage and the high-voltage rise-times are obtained for a set of values of the bypass impedance (R or L). The optimum bypass impedance turns out to be an inductance. During the discharge period, the plasma load is considered as an LR impedance, each component being time dependent. A method is presented for giving us the possibility to introduce the time varying impedances in a PSPICE program. Finally, a set of simulation results (plasma current and voltage, plasma magnetic energy, plasma sheath mechanical energy, pinch voltage) is shown. The results are in good agreement with the classical experimental data. (author). 2 figs., 4 refs.

  6. Neutron and X-ray emission studies in a low energy plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Zakaullah, M. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics; Murtaza, G. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics; Qamar, S. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics; Ahmad, I. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics; Beg, M.M. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics

    1996-03-01

    In a low energy Mather-type plasma focus energized by a single 32 {mu}F capacitor, the X-ray and neutron emission is investigated using time-integrated and time-resolved detectors. The X-ray emission profile has a width (FWHM) of 40-50 ns. The neutron emission profile is broader compared to the X-ray emission profile and also delayed by 30-40 ns. To identify different regimes of X-ray emission, an X-ray pin-hole camera along with different absorption filters is employed. While the X-ray emission is high within a narrow pressure range of 2.0-2.5 mbar, the neutron emission is intense for a wider range of 1.0-4.5 mbar. The intense X-ray emission seems to originate from the axially moving shock wave. These results also indicate rather different production mechanisms for X-ray and neutron emission. Also on comparing the X-ray images with Al(2 {mu}m), Al(5 {mu}m), Al(9 {mu}m) filters, we find that the bulk of X-rays from the focus filament have energies less than 2 keV. (orig.).

  7. Emerging treatments in type 2 diabetes: focus on canagliflozin

    Directory of Open Access Journals (Sweden)

    Rosiak M

    2014-08-01

    Full Text Available Marek Rosiak,1,2 Susanna Grzeszczak,2 Dariusz A Kosior,2,3 Marek Postuła1,2 1Department of Cardiology and Hypertension, Central Clinical Hospital, the Ministry of the Interior, Warsaw, Poland; 2Department of Experimental and Clinical Pharmacology, Medical University of Warsaw, Poland; 3Mossakowski Medical Research Centre, Polish Academy of Sciences, Warsaw, Poland Abstract: Type 2 diabetes mellitus (T2DM is a prevalent metabolic disorder, which affects more than 300 million people globally. The common effect of uncontrolled diabetes is the state of hyperglycemia, which results from beta-cell dysfunction as well as insulin resistance, which is accompanied with microvascular and macrovascular complications. As hyperglycemia defines diabetes, glycemic control is fundamental to the management of diabetes. Sodium glucose co-transporter 2 inhibitors (SGLT2 are a new group of oral antidiabetic medications that act by blocking the reabsorption of glucose, causing it to be excreted in the urine. Canagliflozin was the first SGLT2 inhibitor to be approved in the US by the Food and Drug Administration for the treatment and control of T2DM and on September 19, 2013, the Committee for Medicinal Products for Human Use of the European Medicines Agency adopted a positive opinion, recommending the granting of a marketing authorization for the medicinal product Invokana®. Canagliflozin is a SGLT2 inhibitor, which acts upon the proximal tubules of the kidneys and reduces the renal threshold for glucose. It is highly selective, binding 250 times more potently to SGLT2 than sodium glucose co-transporter 1 inhibitor. This action allows a higher amount of glucose to be excreted within the urine, causing the patient's plasma glucose level to be decreased and indirectly causing weight loss. Among the most common adverse events are hypoglycemia, headache, nausea, female genital and urinary tract infections, nasopharyngitis, and transient postural dizziness. Given its

  8. Self-focusing and self-defocusing of elliptically shaped Gaussian laser beams in plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Nayyar, V P; Soni, V S [Punjabi Univ., Patiala (India). Dept. of Physics

    1979-02-14

    This paper presents a study of the self-focusing and self-defocusing of elliptically shaped Gaussian laser beams in collisional and collisionless plasmas. The non-linear dependence of the dielectric constant inside a collisional plasma is due to inhomogeneous heating of energy carriers and in a collisionless plasma it is due to the ponderomotive force. It is found that the beam gets focused at different points in different planes, exhibiting the effect of astigmatism. In certain power regions considered, the beam either converges or defocuses in both the directions, while in some other regions of the power spectrum one dimension of the beam focuses while the other defocuses. The beam also propagates in an oscillatory waveguide.

  9. The dense plasma focus and nuclear energy. A possible path towards fuel-selfsufficiency

    International Nuclear Information System (INIS)

    Heindler, M.; Harms, A.A.

    1983-01-01

    This chapter examines the concept of incorporating a dense plasma focus device which supplies neutrons to breed fissile fuel for fission reactions in a nuclear energy system. Discusses the dense plasma focus in a fusion-fission symbiont concept; a parametric description of a DPF-based nuclear energy system; fissile fuel and energy balance in a DPF based symbiont; a fusion-fission symbiont with a DPF device of current design; and DPF facility requirements for a self-sufficient fusion-fission symbiont. The primary objective of this study was to establish a systems concept which is essentially self-sufficient with respect to nuclear fuel. Concludes that while existing dense plasma focus devices are insufficient and inadequate for such purpose, the improvement of some critical performance parameters (e.g., the pulse repetition rate and the neutron yield per pulse) could render a self-sufficient nuclear energy concept a nearterm technological objective

  10. Hard TiCx/SiC/a-C:H nanocomposite thin films using pulsed high energy density plasma focus device

    International Nuclear Information System (INIS)

    Umar, Z.A.; Rawat, R.S.; Tan, K.S.; Kumar, A.K.; Ahmad, R.; Hussain, T.; Kloc, C.; Chen, Z.; Shen, L.; Zhang, Z.

    2013-01-01

    Highlights: •The energetic ions and electron beams are used to synthesize TiC x /SiC/a-C:H films. •As-deposited crystalline and hard nanocomposite TiC x /SiC/a-C:H films are synthesized. •Very high average deposition rates of 68 nm/shot are achieved using dense plasma focus. •The maximum hardness of 22 GPa is achieved at the surface of the film. -- Abstract: Thin films of TiC x /SiC/a-C:H were synthesized on Si substrates using a complex mix of high energy density plasmas and instability accelerated energetic ions of filling gas species, emanated from hot and dense pinched plasma column, in dense plasma focus device. The conventional hollow copper anode of Mather type plasma focus device was replaced by solid titanium anode for synthesis of TiC x /SiC/a-C:H nanocomposite thin films using CH 4 :Ar admixture of (1:9, 3:7 and 5:5) for fixed 20 focus shots as well as with different number of focus shots with fixed CH 4 :Ar admixture ratio 3:7. XRD results showed the formation of crystalline TiC x /SiC phases for thin film synthesized using different number of focus shots with CH 4 :Ar admixture ratio fixed at 3:7. SEM results showed that the synthesized thin films consist of nanoparticle agglomerates and the size of agglomerates depended on the CH 4 :Ar admixture ratio as well as on the number of focus shots. Raman analysis showed the formation of polycrystalline/amorphous Si, SiC and a-C for different CH 4 :Ar ratio as well as for different number of focus shots. The XPS analysis confirmed the formation of TiC x /SiC/a-C:H composite thin film. Nanoindentation results showed that the hardness and elastic modulus values of composite thin films increased with increasing number of focus shots. Maximum values of hardness and elastic modulus at the surface of the composite thin film were found to be about 22 and 305 GPa, respectively for 30 focus shots confirming the successful synthesis of hard composite TiC x /SiC/a-C:H coatings

  11. Cross focusing of mixed mode operation in an extra dense plasma

    Energy Technology Data Exchange (ETDEWEB)

    Soni, V S; Nayyar, V P [Punjabi Univ., Patiala (India). Dept. of Physics

    1979-08-01

    This paper presents a study of the nonlinear propagation of a mixture of two degenerate modes (TEM/sub 00/ and TEM/sub 10/) of a high power laser beam in an extradense plasma. The high irradiance inhomogeneous laser beam creates an electron density gradient region in the overdense plasma (n > nsub(c)) through which the beam can propagate. The focusing effects have been studied for different power ratios of the two modes (TEM/sub 00/ mode is considered to be stronger than the TEM/sub 10/ mode). Self-focusing of the beam in x and y directions for critical power has been extensively studied.

  12. Detection of light charged particles from plasma focus by CR-39

    Energy Technology Data Exchange (ETDEWEB)

    Antanasijevic, R.; Vukovic, J.; Popovic, S.; Popovic, M. (Belgrade Univ. (Yugoslavia). Inst. za Fiziku); Puric, J.; Cuk, M. (Faculty of Physical Science, Belgrade (Yugoslavia))

    1991-01-01

    An analysis of a deuteron (D{sup +}) beam, emitted from a plasma focus has been carried out, using a CR-39 plastic nuclear track detector. The CR-39 was pretreated using different processes to destroy the existing background before exposing it to the particles produced in the plasma focus. From measurements of the diameters of the tracks, the estimated energy of the D{sup +} ions is about 0.5 MeV. The total number of emitted D{sup +} ions was 10 particles/pulse. Some preliminary results on imaging etched CR-39 with an Atomic Force Microscope (NanoScope AFM) are also presented. (author).

  13. Detection of light charged particles from plasma focus by CR-39

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Vukovic, J.; Popovic, S.; Popovic, M.

    1991-01-01

    An analysis of a deuteron (D + ) beam, emitted from a plasma focus has been carried out, using a CR-39 plastic nuclear track detector. The CR-39 was pretreated using different processes to destroy the existing background before exposing it to the particles produced in the plasma focus. From measurements of the diameters of the tracks, the estimated energy of the D + ions is about 0.5 MeV. The total number of emitted D + ions was 10 particles/pulse. Some preliminary results on imaging etched CR-39 with an Atomic Force Microscope (NanoScope AFM) are also presented. (author)

  14. Dense Plasma Focus: A question in search of answers, a technology in search of applications

    International Nuclear Information System (INIS)

    Auluck, S.K.H.

    2014-01-01

    Diagnostic information accumulated over four decades of research suggests a directionality of toroidal motion for energetic ions responsible for fusion neutron production in the Dense Plasma Focus (DPF) and existence of an axial component of magnetic field even under conditions of azimuthal symmetry. This is at variance with the traditional view of Dense Plasma Focus as a purely irrotational compressive flow. The difficulty in understanding the experimental situation from a theoretical standpoint arises from polarity of the observed solenoidal state: three independent experiments confirm existence of a fixed polarity of the axial magnetic field or related azimuthal current. Since the equations governing plasma dynamics do not have a built-in direction, the fixed polarity must be related with initial conditions: the plasma dynamics must interact with an external physical vector in order to generate a solenoidal state of fixed polarity. Only four such external physical vectors can be identified: the earth's magnetic field, earth's angular momentum, direction of current flow and the direction of the plasma accelerator. How interaction of plasma dynamics with these fields can generate observed solenoidal state is a question still in search of answers; this paper outlines one possible answer. The importance of this question goes beyond scientific curiosity into technological uses of the energetic ions and the high-power-density plasma environment. However, commercial utilization of such technologies faces reliability concerns, which can be met only by first-principles integrated design of globally-optimized industrial-quality DPF hardware. Issues involved in the emergence of the Dense Plasma Focus as a technology platform for commercial applications in the not-too-distant future are discussed. (author)

  15. Fine structure of modal focusing effect in a three dimensional plasma-sheath-lens formed by disk electrodes

    DEFF Research Database (Denmark)

    Stamate, Eugen; Yamaguchi, Masahito

    2015-01-01

    Modal and discrete focusing effects associated with three-dimensional plasma-sheath-lenses show promising potential for applications in ion beam extraction, mass spectrometry, plasma diagnostics and for basic studies of plasma sheath. The ion focusing properties can be adjusted by controlling the...

  16. Deposition and surface characterization of nanoparticles of zinc oxide using dense plasma focus device in nitrogen atmosphere

    International Nuclear Information System (INIS)

    Malhotra, Yashi; Srivastava, M P; Roy, Savita

    2010-01-01

    Nanoparticles of zinc oxide from zinc oxide pellets in the nitrogen plasma atmosphere are deposited on n and p type silicon substrates using Dense Plasma Focus device. The hot and dense nitrogen plasma formed during the focus phase ionizes the ZnO pellet, which then move upward in a fountain like shape and gets deposited on substrates which are placed above the top of the anode. Structural and surface properties of the deposited ZnO are investigated using X-ray diffraction and Atomic force microscope (AFM). X-ray spectra shows the diffraction plane (002) of ZnO nanoparticles deposited on Si with few shots in nitrogen atmosphere. AFM investigations revealed that there are nanoparticles of size between 15-80 nm on n-Si and p-Si substrates. The deposition on n-type Si is better than the p-type Si can be seen from AFM images, this may be due to different orientation of silicon.

  17. Electrostatic storage ring with focusing provided by the space charge of an electron plasma

    International Nuclear Information System (INIS)

    Pacheco, J. L.; Ordonez, C. A.; Weathers, D. L.

    2013-01-01

    Electrostatic storage rings are used for a variety of atomic physics studies. An advantage of electrostatic storage rings is that heavy ions can be confined. An electrostatic storage ring that employs the space charge of an electron plasma for focusing is described. An additional advantage of the present concept is that slow ions, or even a stationary ion plasma, can be confined. The concept employs an artificially structured boundary, which is defined at present as one that produces a spatially periodic static field such that the spatial period and range of the field are much smaller than the dimensions of a plasma or charged-particle beam that is confined by the field. An artificially structured boundary is used to confine a non-neutral electron plasma along the storage ring. The electron plasma would be effectively unmagnetized, except near an outer boundary where the confining electromagnetic field would reside. The electron plasma produces a radially inward electric field, which focuses the ion beam. Self-consistently computed radial beam profiles are reported.

  18. Geometrical optimization of an ellipsoidal plasma mirror toward tight focusing of ultra-intense laser pulse

    International Nuclear Information System (INIS)

    Kon, A; Nakatsutsumi, M; Chen, Z L; Kodama, R; Buffechoux, S; Fuchs, J; Jin, Z

    2010-01-01

    We developed for the first time, very compact ( 3 ) extremely low f-number (f/number = 0.4) confocal ellipsoid focusing systems. Direct measurement of the laser focal spot using a low-energy laser beam indicates 1/5 reduction of the spot size compared to standard focusing (using a f/2.7 optics). Such mirror is thus able to achieve significant enhancement of the focused laser intensity without modifying the laser system itself. The mirror is then used under plasma mirror regime which enables us to compactify the size, to liberate us from the anxiety of protecting the optics from target debris after shots, and to enhance the temporal contrast. In this paper, we focus our attention to designing and optimizing the geometry of such innovative plasma optics.

  19. Soft X-ray spectroscopic investigation of a plasma focus operated in pure neon

    International Nuclear Information System (INIS)

    Presura, R.; Zoita, V.; Paraschiv, I.

    1996-01-01

    The soft X-ray emission of the medium-energy plasma focus device IPF-2/20 operated in pure neon was studied with spectral resolution. The spectra of H- and He-like Ne ions were recorded by means of a de Broglie spectrograph for initial filling pressures in the range 1.3 to 7 torr. Both the soft X-ray emission characteristics and the plasma parameters are strongly dependent on the working gas pressure. The intensity of the He-like neon ions lines increases when the working gas pressure is raised, while for the H-like ions it has a maximum for about 5 torr filling. The electron density has values of the order of 10 20 cm -3 . The electron temperature ranges between 300 and 350 eV. Both the plasma density and the plasma temperature decrease when the initial gas pressure is increased. (author). 2 figs., 9 refs

  20. The use of convalescent plasma to treat emerging infectious diseases: focus on Ebola virus disease.

    Science.gov (United States)

    Winkler, Anne M; Koepsell, Scott A

    2015-11-01

    The purpose of this review is to discuss the use of convalescent plasma for the treatment of emerging infectious diseases, focusing on the recent use for the treatment of Ebola virus disease (EVD). Ebola convalescent plasma has been used as a therapy for treatment of EVD during the 2014 West Africa epidemic. Several cases from the United States and Europe have been recently published, in addition to multiple ongoing clinical trials in the United States and West Africa. Even more recently, convalescent plasma has been used for treatment of individuals with Middle East respiratory syndrome coronavirus (MERS-CoV) infection. Although the first reports of successful treatment with passive immune therapy date back to the early 1900s, convalescent plasma has materialized as a possible therapy for patients who develop infection from one of the emerging infectious diseases such as EVD or MERS-CoV, although the efficacy of such therapy has yet to be proven in clinical trials.

  1. Soft X-ray spectroscopic investigation of a plasma focus operated in pure neon

    Energy Technology Data Exchange (ETDEWEB)

    Presura, R; Zoita, V; Paraschiv, I [Inst. of Physics and Technology of Radiation Devices, Bucharest (Romania)

    1997-12-31

    The soft X-ray emission of the medium-energy plasma focus device IPF-2/20 operated in pure neon was studied with spectral resolution. The spectra of H- and He-like Ne ions were recorded by means of a de Broglie spectrograph for initial filling pressures in the range 1.3 to 7 torr. Both the soft X-ray emission characteristics and the plasma parameters are strongly dependent on the working gas pressure. The intensity of the He-like neon ions lines increases when the working gas pressure is raised, while for the H-like ions it has a maximum for about 5 torr filling. The electron density has values of the order of 10{sup 20} cm{sup -3}. The electron temperature ranges between 300 and 350 eV. Both the plasma density and the plasma temperature decrease when the initial gas pressure is increased. (author). 2 figs., 9 refs.

  2. Electron beam effects on the spectroscopy of multiply charged ions in plasma focus experiments

    International Nuclear Information System (INIS)

    Abdallah, J.; Clark, R.E.H.; Faenov, A.Y.; Karpinski, L.; Pikuz, S.A.; Romanova, V.M.; Sadowski, M.; Scholz, M.; Szydlowski, A.

    1999-01-01

    Argon-hydrogen mixture plasma focus experiments performed at the Warsaw Institute of Plasma Physics and Laser Microfusion show detailed space resolved spectra for Ar K-shell satellite lines up to F-like Ar and K-alpha of Ar. These transitions originating from autoionizing levels are caused by collisions of ions with the energetic electron beams which are created by the constrictions of the plasma column due to the development of magnetohydrodynamic instabilities. A collisional-radiative model was constructed using a non-Maxwellian electron energy distribution consisting of a thermal Maxwellian part plus a Gaussian part to represent the high-energy electron beam. The shapes of the observed satellite structures are consistent with the calculated spectrum for electron temperatures between 20 and 230 eV, and beam densities of about 10 -3 times the plasma electron density. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  3. Electron beam effects on the spectroscopy of multiply charged ions in plasma focus experiments

    Energy Technology Data Exchange (ETDEWEB)

    Abdallah, J. [UCLA Plasma Physics Laboratory, Los Angeles, CA (United States); Clark, R.E.H. [Los Alamos National Laboratory, Los Alamos, NM (United States); Faenov, A.Y. [MISDC, NPO ' VNIIFTRI' , Mendeleevo, Moscow region, 141570 (Russian Federation); Karpinski, L. [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Pikuz, S.A.; Romanova, V.M. [P. N. Lebedev Physical Institute, Moscow (Russian Federation); Sadowski, M. [Soltan Institute for Nuclear Studies, Swierk (Poland); Scholz, M.; Szydlowski, A. [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland)

    1999-05-01

    Argon-hydrogen mixture plasma focus experiments performed at the Warsaw Institute of Plasma Physics and Laser Microfusion show detailed space resolved spectra for Ar K-shell satellite lines up to F-like Ar and K-alpha of Ar. These transitions originating from autoionizing levels are caused by collisions of ions with the energetic electron beams which are created by the constrictions of the plasma column due to the development of magnetohydrodynamic instabilities. A collisional-radiative model wasconstructed using a non-Maxwellian electron energy distribution consisting of a thermal Maxwellian part plus a Gaussian part to represent the high-energy electron beam. The shapes of the observed satellite structures are consistent with the calculated spectrum for electron temperatures between 20 and 230 eV, and beam densities of about 10{sup -3} times the plasma electron density. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  4. Time resolved x-ray photography of a dense plasma focus

    International Nuclear Information System (INIS)

    Burnett, J.C.; Meyer, J.; Rankin, G.

    1977-01-01

    The temporal development of the hot plasma in a dense plasma focus is studied by x-ray streak photography of approximately 2 ns resolution time. It is shown that initially a uniform x-ray emitting pinch plasma is formed which subsequently cools down until x-ray emission stops after approximately 50 ns. At a time of around 100 ns after initial x-ray emission coinciding with the break-up time of the pinch a second burst of x-rays is observed coming from small localized regions. The observations are compared with results obtained from time-resolved shadow and schlieren photography of a similar dense focus discharge. (author)

  5. On the Self-Focusing of Whistler Waves in a Radial Inhomogeneous Plasma

    DEFF Research Database (Denmark)

    Balmashnov, A. A.

    1980-01-01

    The process of whistler wave self-focusing is experimentally investigated. It was found that a whistler wave propagating along the plasma column with a density crest excites a longitudinal wave of the same frequency propagating across the external magnetic field. The amplitude modulation of the l......The process of whistler wave self-focusing is experimentally investigated. It was found that a whistler wave propagating along the plasma column with a density crest excites a longitudinal wave of the same frequency propagating across the external magnetic field. The amplitude modulation...... of the latter wave is accompanied by a density modification, which leads to trapping of the whistler wave in a density trough in the center of the plasma column....

  6. Noise Suppression and Enhanced Focusability in Plasma Raman Amplifier with Multi-frequency Pump

    International Nuclear Information System (INIS)

    Balakin, A.A.; Fraiman, G.M.; Fisch, N.J.; Malkin, V.M.

    2003-01-01

    Laser pulse compression/amplification through Raman backscattering in plasmas can be facilitated by using multi-frequency pump laser beams. The efficiency of amplification is increased by suppressing the Raman instability of thermal fluctuations and seed precursors. Also the focusability of the amplified radiation is enhanced due to the suppression of large-scale longitudinal speckles in the pump wave structure

  7. Factors which affect operation of a plasma focus in various gases

    International Nuclear Information System (INIS)

    Smith, A.J.

    1987-06-01

    It is shown that the axial transit time t a and γ, the ratio of specific heats, are the main factors which affect the operation of a plasma focus in various gases. An energy balance theory is used to explore this dependence. The results are consistent with previous calculations and with experiment. (author). 12 refs

  8. Analysis of the results obtained by optical measurements in plasma focus equipments

    International Nuclear Information System (INIS)

    Bilbao, L.; Bruzzone, H.

    1982-01-01

    The results obtained by shadow and Schlieren photographies and interferometry in a 1MJ plasma focus device of Frascati (CNEN-EURATOM, Italy) are compared with a great number of similar measurement results in several devices of the world. A critical analysis of the above results is presented. (L.C.) [pt

  9. Surface ionization wave in a plasma focus-like model device

    International Nuclear Information System (INIS)

    Yordanov, V; Blagoev, A; Ivanova-Stanik, I; Veldhuizen, E M van; Nijdam, S; Dijk, J van; Mullen, J J A M van der

    2008-01-01

    A numerical particle in cell-Monte Carlo model of the breakdown in the plasma focus device simulates the development of an ionization wave sliding along the insulator. In order to validate this model a planar model device is created. The pictures of the discharges taken by a fast optical camera show that we have qualitative agreement between the model and the experimental observations.

  10. Surface ionization wave in a plasma focus-like model device

    Energy Technology Data Exchange (ETDEWEB)

    Yordanov, V; Blagoev, A [Faculty of Physics, University of Sofia, 5 James Bourchier Blvd, BG-1164, Sofia (Bulgaria); Ivanova-Stanik, I [IPPLM, 23 Hery St, PO Box 49, PL-00-908 Warsaw (Poland); Veldhuizen, E M van; Nijdam, S; Dijk, J van; Mullen, J J A M van der [Department of Applied Physics, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands)], E-mail: v.yordanov@phys.uni-sofia.bg

    2008-11-07

    A numerical particle in cell-Monte Carlo model of the breakdown in the plasma focus device simulates the development of an ionization wave sliding along the insulator. In order to validate this model a planar model device is created. The pictures of the discharges taken by a fast optical camera show that we have qualitative agreement between the model and the experimental observations.

  11. Hard X-ray dosimetry of a plasma focus suitable for industrial radiography

    Science.gov (United States)

    Knoblauch, P.; Raspa, V.; Di Lorenzo, F.; Clausse, A.; Moreno, C.

    2018-04-01

    Dosimetric measurements of the hard X-ray emission by a small-chamber 4.7 kJ Mather-type plasma focus device capable of producing neat radiographs of metallic objects, were carried out with a set of thermoluminescent detectors TLD 700 (LiF:Mg,Ti). Measurements of the hard X-ray dose dependence with the angular position relative to the electrodes axis, are presented. The source-detector distance was changed in the range from 50 to 100 cm, and the angular positions were explored between ± 70°, relative to the symmetry axis of the electrodes. On-axis measurements show that the X-ray intensity is uniform within a half aperture angle of 6°, in which the source delivers an average dose of (1.5 ± 0.1) mGy/sr per shot. Monte Carlo calculations suggest that the energy of the electron beam responsible for the X-ray emission ranges 100-600 keV.

  12. Self-focusing of nonlinear waves in a relativistic plasma with positive and negative ions

    International Nuclear Information System (INIS)

    Mukherjee, Joydeep; Chowdhury, A.R.

    1994-01-01

    The phenomenon of self-focusing of nonlinear waves was analysed in a relativistic plasma consisting of both positive and negative ions, which are assumed to be hot. The effect of the inertia of the relativistic electron is also considered by treating it dynamically. A modified form of reductive perturbation is used to deduce a nonlinear Schroedinger equation describing the purely spatial variation of the nonlinear wave. Self-focusing of the wave can be ascertained by analysing the transversal stability of the solitary wave. It is shown that the zones of stability of the wave may become wider due to the mutual influence of various factors present in the plasma, thus favouring the process of self-focusing. 10 refs., 2 figs

  13. Developing a plasma focus research training system for the fusion energy age

    International Nuclear Information System (INIS)

    Lee, S.

    2014-01-01

    The 3 kJ UNU/ICTP Plasma Focus Facility is the most significant device associated with the AAAPT (Asian African Association for Plasma Training). In original and modified/upgraded form it has trained generations of plasma focus (PF) researchers internationally, producing many PhD theses and peer-reviewed papers. The Lee Model code was developed for the design of this PF. This code has evolved to cover all PF machines for design, interpretation and optimization, for derivation of radiation scaling laws; and to provide insights into yield scaling limitations, radiative collapse, speed-enhanced and current-stepped PF variants. As example of fresh perspectives derivable from this code, this paper presents new results on energy transfers of the axial and radial phases of generalized PF devices. As the world moves inexorably towards the Fusion Energy Age it becomes ever more important to train plasma fusion researchers. A recent workshop in Nepal shows that demand for such training continues. Even commercial project development consultants are showing interest. We propose that the AAAPT-proven research package be upgraded, by modernizing the small PF for extreme modes of operation, switchable from the typical strong-focus mode to a slow-mode which barely pinches, thus producing a larger, more uniform plasma stream with superior deposition properties. Such a small device would be cost-effective and easily duplicated, and have the versatility of a range of experiments from intense multi-radiation generation and target damage studies to superior advanced-materials deposition. The complementary code is used to reference experiments up to the largest existing machine. This is ideal for studying machine limitations and scaling laws and to suggest new experiments. Such a modernized versatile PF machine complemented by the universally versatile code would extend the utility of the PF experience; so that AAAPT continues to provide leadership in pulsed plasma research training in

  14. Time-resolved characteristics of deuteron-beam generated by plasma focus discharge

    Science.gov (United States)

    Bradley, D. A.

    2018-01-01

    The plasma focus device discussed herein is a Z-pinch pulsed-plasma arrangement. In this, the plasma is heated and compressed into a cylindrical column, producing a typical density of > 1025 particles/m3 and a temperature of (1–3) × 107 oC. The plasma focus has been widely investigated as a radiation source, including as ion-beams, electron-beams and as a source of x-ray and neutron production, providing considerable scope for use in a variety of technological situations. Thus said, the nature of the radiation emission depends on the dynamics of the plasma pinch. In this study of the characteristics of deuteron-beam emission, in terms of energy, fluence and angular distribution were analyzed. The 2.7 kJ plasma focus discharge has been made to operate at a pressure of less than 1 mbar rather than at its more conventional operating pressure of a few mbar. Faraday cup were used to determine deuteron-beam energy and deuteron-beam fluence per shot while CR-39 solid-state nuclear track detectors were employed in studying the angular distribution of deuteron emission. Beam energy and deuteron-beam fluence per shot have been found to be pressure dependent. The largest value of average deuteron energy measured for present conditions was found to be (52 ± 7) keV, while the deuteron-beam fluence per shot was of the order of 1015 ions/m2 when operated at a pressure of 0.2 mbar. The deuteron-beam emission is in the forward direction and is observed to be highly anisotropic. PMID:29309425

  15. Synthesis of nano-crystalline zirconium aluminium oxynitride (ZrAlON) composite films by dense plasma Focus device

    Energy Technology Data Exchange (ETDEWEB)

    Khan, I.A.; Hassan, M.; Hussain, T. [Department of Physics, GC University, 54000 Lahore (Pakistan); Ahmad, R., E-mail: ahriaz@gmail.com [Department of Physics, GC University, 54000 Lahore (Pakistan); Zakaullah, M. [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Rawat, R.S. [National Institute of Education, Nanyang Technological University, Singapore 637616 (Singapore)

    2009-04-01

    Zirconium aluminium oxynitride multiphase composite film is deposited on zirconium substrate using energetic nitrogen ions delivered from dense plasma Focus device. X-ray diffractometer (XRD) results show that five Focus shots are sufficient to initiate the nucleation of ZrN and Al{sub 2}O{sub 3} whereas 10 Focus shots are sufficient to initiate the nucleation of AlN. XRD results reveal that crystal growth of nitrides/oxides increases by increasing Focus shots (up to 30 Focus shots) and resputtering of the previously deposited film is taken place by further increase in Focus shots (40 Focus shots). Scanning electron microscopic (SEM) results indicate the uniform distribution of spherical grains ({approx}35 nm). A smoother surface is observed for 20 Focus shots at 0 deg. angular position. SEM results also show a net-type microstructure (thread like features) of the sample treated for 30 Focus shots whereas rough surface morphology is observed for 40 Focus shots. Energy dispersive spectroscopic profiles show the distribution of different elements present in the deposited composite films. A typical microhardness value of the deposited composite films is 5255 {+-} 10 MPa for 10 grams imposed load which is 3.3 times than the microhardness values of unexposed sample. The microhardness values of the exposed samples increases with increasing Focus shots (up to 30 Focus shots) and decreases for 40 Focus shots treatment due to resputtering of the previously deposited composite film. The microhardness values of the composite films decreases by increasing the sample's angular position.

  16. Relativistic self-focusing of intense laser beam in thermal collisionless quantum plasma with ramped density profile

    Directory of Open Access Journals (Sweden)

    S. Zare

    2015-04-01

    Full Text Available Propagation of a Gaussian x-ray laser beam has been analyzed in collisionless thermal quantum plasma with considering a ramped density profile. In this density profile due to the increase in the plasma density, an earlier and stronger self-focusing effect is noticed where the beam width oscillates with higher frequency and less amplitude. Moreover, the effect of the density profile slope and the initial plasma density on the laser propagation has been studied. It is found that, by increasing the initial density and the ramp slope, the laser beam focuses faster with less oscillation amplitude, smaller laser spot size and more oscillations. Furthermore, a comparison is made among the laser self-focusing in thermal quantum plasma, cold quantum plasma and classical plasma. It is realized that the laser self-focusing in the quantum plasma becomes stronger in comparison with the classical regime.

  17. Focus on Vitamin D, Inflammation and Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Marcelo Macedo Rogero

    2012-01-01

    Full Text Available The initial observations linking vitamin D to type 2 diabetes in humans came from studies showing that both healthy and diabetic subjects had a seasonal variation of glycemic control. Currently, there is evidence supporting that vitamin D status is important to regulate some pathways related to type 2 diabetes development. Since the activation of inflammatory pathways interferes with normal metabolism and disrupts proper insulin signaling, it is hypothesized that vitamin D could influence glucose homeostasis by modulating inflammatory response. Human studies investigating the impact of vitamin D supplementation on inflammatory biomarkers of subjects with or at high risk of developing type 2 diabetes are scarce and have generated conflicting results. Based on available clinical and epidemiological data, the positive effects of vitamin D seem to be primarily related to its action on insulin secretion and sensitivity and secondary to its action on inflammation. Future studies specifically designed to investigate the role of vitamin D on type 2 diabetes using inflammation as the main outcome are urgently needed in order to provide a more robust link between vitamin D, inflammation and type 2 diabetes.

  18. Plasma density measurement with ring-type cutoff probe

    International Nuclear Information System (INIS)

    Kim, D.W.; You, S.J.; Na, B.K.; Kim, J.H.; Shin, Y.H.; Chang, H.Y.; Oh, W.Y.

    2013-01-01

    We proposed a cutoff probe with a ring-type detection tip enclosing a bar-type radiation tip. A comparative study between a proposed ring-type cutoff (RTC) probe and a conventional bar-type cutoff (BTC) probe showed that the RTC probe solved the problem of the BTC probe, the large measurement uncertainty of the electron density in a capacitively coupled plasma source. This improved characteristics of the RTC probe might have originated from the geometrical structure of the RTC probe concerning the monopole antennae radiation. This proposed cutoff probe can be expected to expand the applicable diagnostic range and to enhance the sensitivity of the cutoff probe. - Highlights: ► A cutoff probe with a ring type detection tip is proposed. ► Comparative experiment and simulation were conducted. ► The proposed probe showed a small uncertainty of measured plasma density. ► Improved characteristics might be originated from the geometrical structure

  19. Measurement of the time dependent neutron energy spectrum in the 'DENA' plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Abdollahzadeh, M [Department of Physics, Imam Husein University, PO Box 16575-347, Tehran (Iran, Islamic Republic of); Sadat kiai, S M [Nuclear Science and Technology Research Institute (NSTRI), Nuclear Science Research School, A.E.O.I., PO Box 14155-1339, Tehran (Iran, Islamic Republic of); Babazadeh, A R [Physics Department, Qom University, PO Box 37165, Qom (Iran, Islamic Republic of)

    2008-10-15

    An extended time of flight method is used to determine the time dependent neutron energy spectrum in the Filippove type 'Dena' plasma focus (90 kJ, 25 kV, 288 {mu}F), filled with deuterium gas. An array of 5 detectors containing NE-102 plastic scintillators+photomultipliers is used. The number and position of the detectors are determined by a Monte Carlo program and the MCNP code. This paper briefly describes the simulation method and presents the experimental measurements and their results. The mechanisms of neutron production (thermonuclear and non-thermonuclear) and their time variations are discussed.

  20. Highly ionized copper contribution to the soft X-ray emission in a plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Zoita, V; Patran, A [Inst. of Physics and Technology of Radiation Devices, Bucharest (Romania); Larour, J [Ecole Polytechnique, Palaiseau (France). Lab. de Physique des Milieux Ionises

    1997-12-31

    In order to discriminate between the contributions of the gas plasma and of the anode (solid or plasma) to the soft X-ray emission in a plasma focus device, a series of experiments was carried out using the following combinations of experimental conditions: various gases, different absorption filters and viewing different regions in front of the centre electrode. The experiments were performed on the IPF-2/20 plasma focus device using the following working gases: helium, neon and helium-argon mixtures. The diagnostics used: magnetic probe for current derivative, PIN diode for the minimum pinch radius detection, PIN diodes for the soft X-ray emission, scintillator-photomultiplier detector for the hard X-ray emission. From the analysis of the various diagnostics data recorded with very good time correlation, it followed that the soft K-ray signals had a strong contribution from optical transitions of the highly ionised Cu (Cu XX to XXII) emitting in the range 0.8-1.3 nm. (author). 7 figs., 9 refs.

  1. Spectrum of reflected light by self-focusing of light in a laser plasma

    International Nuclear Information System (INIS)

    Gorbunov, L.M.

    1983-01-01

    The spectrum of the radiation reflected by a laser-produced plasma is considered. In this situation, self-focusing occurs and a region of low density (caviton) is formed. It is shown that the process leads to a considerable broadening of the spectrum on the ''red'' side, and to the appearance of a line structure in the spectrum. The results can explain data for the reflected light spectrum [L. M. Gorbunov et al., FIAN Preprint No. 126 (1979)] as being due to the nonstationary self-focusing of light in a laser-produced plasma that has recently been observed [V. L. Artsimovich et al., FIAN Preprint No. 252 (1981); Sov. Phys. Doklady 27, 618 (1982)

  2. Preliminary results on a 4 kJ, 140 k A plasma focus

    International Nuclear Information System (INIS)

    Silva, Patricio; Favre, Mario; Chuaqui, Hernan; Wyndham, Edmund

    1996-01-01

    Preliminary results on the operation of a 4 kJ, 140 kA Plasma Focus device are presented. The machine operates Hydrogen and Hydrogen-Argon mixtures at pressures between 400 m Torr to 10 Torr. Main diagnostics include electric and current measurements, time and space resolved X-ray observations, with limited spectral resolution, and B-dot sensors to monitor the evolution of de current sheet during the run up phase of the discharge. The results indicate that good focus is obtained in the above pressure range. This is inferred from I-dot traces and Pin diode and pin-hole camera X-ray observations. The B-dot loops suggest that a symmetric current sheet is produced. These results show that the machine exhibits a reliable performance, which allows further studies on dense transient plasmas to be developed. (author)

  3. System for deuterium-tritium mixture filling the working chamber of a dense plasma focus device

    International Nuclear Information System (INIS)

    Bondar', A.I.; Vyskubov, V.P.; Gerasimov, S.A.

    1981-01-01

    A gas-vacuum system designed for filling the gas-discharge chamber of a plasma focus device with equal-coaponent deuterium-tritium mixture is described. The system consists of a unit for gaseous mixture prepa ration and a unit for mixture absorption and device evacuation. The system provides the gaseous mixture purification of O 2 and N 2 impurities. Final tritium content in the gas-discharge chamber after tritium removal is not greater than 2x10 8 Bq/l. Tritium content in a sealed box in which the device is placed does not exceed 30 Bq/l that is less than limiting safe value. The conclusion is made that the described system design gives an opportunity to begin experimental studies at plasma focus devices with deuterium-tritium mixture [ru

  4. Fusion reaction yield in focused discharges with variable energy and plasma fine structure

    International Nuclear Information System (INIS)

    Bortolotti, A.; Brzosko, J.S.; Chiara, P. De; Kilic, H.; Mezzetti, F.; Nardi, V.; Powell, C.; Wang, J.

    1992-01-01

    The same linear correlation between the distribution parameters (ΔT and Max ΔV) of the radial current density J between electrodes and the fusion reaction yield per pulse, Y, in the plasma focus (PF) pinch was quantitatively determined from different PF machines. Contact prints of current-sheath fragments (CSF) ejected from the pinch are obtained from 2.5-MeV-D + ions. CSF's show the same submillimetric fine structure of the pinch. (author) 3 refs., 2 tabs

  5. Numerical Analysis of Amirkabir Plasma Focus (APF) Device for Neon and Argon Gases

    Science.gov (United States)

    Niknam Sharak, M.; Goudarzi, S.; Raeisdana, A.; Jafarabadi, M.

    2013-04-01

    In this paper the experimental results in different working conditions in Amirkabir Plasma Focus (APF) Device have been compared with the numerical results of a two-dimensional simulation code based on Lee's model. The experiments were done with pure Neon and Argon as operating gases over a wide range of working conditions (gas pressures and discharge voltages). It is observed that by a proper choice for values of the efficiency factors, comparison between numerical and experimental results shows a good agreement.

  6. Experimental Study of Current Discharge Behavior and Hard X-ray Anisotropy by APF Plasma Focus Device

    Science.gov (United States)

    Habibi, M.; Amrollahi, R.; Attaran, M.

    2009-03-01

    Amirkabir (APF) is a new Mather-type plasma focus device (16 kV, 36 μf, and 115 nH). In this work we present some experimental results as variation of discharge current signal respect to applied voltage at the optimum pressure, focusing time of plasma versus gas pressure, and variations of current discharge with different insulator sleeve dimensions. As we prospected optimum pressure tending to increase as we tried to higher voltage levels. The time taken by the current sheath to lift-off the insulator surface and therefore quality of pinched plasma depends on the length of the insulator sleeve. The results show that the insulator diameter can influence on pinch quality. Behavior of hard X-ray (HXR) signals with the pressure and also anisotropy of HXR investigated by the use of two scintillation detectors. The distribution of HXR intensity shows a large anisotropy with a maximum intensity between 22.5° and 45° and also between -22.5° and -67.5°.

  7. Metformin increases plasma ghrelin in Type 2 diabetes.

    Science.gov (United States)

    Doogue, Matthew P; Begg, Evan J; Moore, M Peter; Lunt, Helen; Pemberton, Chris J; Zhang, Mei

    2009-12-01

    * Metformin, unlike the other major antihyperglycaemic drugs, is not associated with weight gain. * Ghrelin is an appetite-stimulating hormone whose concentrations vary in relation to food, obesity and diabetes control. * Reports are conflicting about how metformin affects ghrelin concentrations, and this study was aimed at resolving this issue in patients with Type 2 diabetes. * In this study an increase in ghrelin concentrations was seen in response to metformin treatment in patients with Type 2 diabetes. * This effect was opposite to what might be expected if the effect of metformin on weight control was mediated via suppression of ghrelin. * It is likely that the ghrelin response was secondary to improved glycaemic control. * Meal time changes in appetite and satiety did not correlate with changes in ghrelin, which suggests ghrelin may not be important in meal initiation. Metformin treatment of Type 2 diabetes is not usually associated with weight gain, and may assist with weight reduction. Plasma ghrelin concentrations are inversely associated with obesity and food intake. Metformin might therefore affect ghrelin concentrations, although previous studies have shown variable results in this regard. The primary aim of this study was to determine the effect of metformin on plasma ghrelin, appetite and satiety in patients with Type 2 diabetes. Eighteen patients with Type 2 diabetes were studied before and after 6 weeks of metformin treatment, which was titrated to 1 g b.d. On the study days patients were fed standard meals of 390 kcal at 08.00 and 12.30 h, plasma samples were collected at 15- and 30-min intervals, and appetite and satiety were measured on visual analogue scales. Changes in the area under the concentration-time curves (AUCs) of plasma ghrelin, insulin, glucose, appetite and satiety were assessed and examined for correlations with metformin AUCs. Changes in fasting adiponectin and leptin were also measured. Treatment with metformin increased the

  8. Investigation of the neutron production phases of a large plasma focus device

    International Nuclear Information System (INIS)

    Hayd, A.; Maurer, M.; Meinke, P.; Herold, H.; Bertalot, L.; Deutsch, R.; Grauf, W.; Jaeger, U.; Kaeppeler, H.J.; Lepper, F.; Oppenlaender, T.; Schmidt, H.; Schmidt, R.; Schwarz, J.; Schwoerer, K.; Shakhatre, M.

    1982-09-01

    Plasma dynamic behavior and neutron production in large focus devices with pinch currents of approximately 1 MA have been studied with theoretical as well as experimental methods. For treating turbulent plasma motion, a hybrid code based on the analytical computer algorithm REDUCE was developed. Experimental diagnostics include schlieren photographs, reaction proton localization with pinhole cameras and neutron measurements with Ag-counters and scintillators. Calculated and measured data concern the 280 kJ, 60 kV operational mode of the POSEIDON plasma focus. It is shown that for large pinch currents ( > 500 kA), neutron emission also appears before m = 0 onset in the intermediate phase. This part of the neutron production becomes predominant for very large currents. The lifetime of this intermediate phase strongly increases with increasing current. According to theory, the late phase of the focus is governed by strong turbulence phenomena. The lifetime of the turbulence packets is approximately 150 ns and seems to explain the long lasting neutron emission in this phase. (orig.)

  9. The Z-pinch as plasma lens for the focusing of heavy ion beams

    International Nuclear Information System (INIS)

    Elfers, M.

    1992-04-01

    In the present thesis the influence of a Z-pinch plasma on the shape of heavy-ion beams and the for the understanding of this interaction most important plasma parameters were studied. For this the Z-pinch at the heavy-ion accelerator UNILAC was operated. The magnet field gradients of up to (25 ± 3) T/m occuring in the Z-pinch lead to the plasma-lens effect - the focusing of a charged-particle beam traversing axially the Z-pinch. In this thesis for the first time the focusing of a heavy-ion beam by the azimutal magnetic field of a Z-pinch is described. Different beams with an original diameter of 10 mm were focused. The smallest measured beam diameter amounts to 1 mm half-width. The beam energy amounts to 11.4 MeV/u, which leads at gold as projectile matter to a beam energy of 2.25 GeV. (orig./HSI) [de

  10. Comparison of measured and computed radial trajectories of plasma focus devices UMDPF1 and UMDPF0

    Energy Technology Data Exchange (ETDEWEB)

    Lim, L. H.; Yap, S. L., E-mail: yapsl@um.edu.my; Lim, L. K.; Lee, M. C.; Poh, H. S.; Ma, J. [Plasma Technology Research Centre, Department of Physics, Faculty of Science, University of Malaya, 50603 Kuala Lumpur (Malaysia); Yap, S. S. [UMPEDAC, University of Malaya, 50603 Kuala Lumpur (Malaysia); Faculty of Engineering, Multimedia University, Cyberjaya, 63100 Selangor (Malaysia); Lee, S. [Plasma Technology Research Centre, Department of Physics, Faculty of Science, University of Malaya, 50603 Kuala Lumpur (Malaysia); INTI International University, 71800 Nilai (Malaysia); Institute for Plasma Focus Studies, 32 Oakpark Drive, Chadstone 3148 (Australia)

    2015-09-15

    In published literature, there has been scant data on radial trajectory of the plasma focus and no comparison of computed with measured radial trajectory. This paper provides the first such comparative study. We compute the trajectories of the inward-moving radial shock and magnetic piston of UMDPF1 plasma focus and compare these with measured data taken from a streak photograph. The comparison shows agreement with the measured radial trajectory in terms of average speeds and general shape of trajectory. This paper also presents the measured trajectory of the radially compressing piston in another machine, the UMDPF0 plasma focus, confirming that the computed radial trajectory also shows similar general agreement. Features of divergence between the computed and measured trajectories, towards the end of the radial compression, are discussed. From the measured radial trajectories, an inference is made that the neutron yield mechanism could not be thermonuclear. A second inference is made regarding the speeds of axial post-pinch shocks, which are recently considered as a useful tool for damage testing of fusion-related wall materials.

  11. The Dense Plasma Focus Group of IFAS at Argentina: A brief history and recent direction of the investigations

    International Nuclear Information System (INIS)

    Milanese, Maria Magdalena

    2006-01-01

    This is a short review of the research done by the Dense Plasma Focus Group (GPDM) presently working in Tandil, Argentina, from its origin, more than three decades ago, as part of the Plasma Physics Laboratory of Buenos Aires University (the first one in Latin-America where experiments in plasma focus have been made) up to the present. The interest has been mainly experimental studies on plasma focus and, in general, fast electrical discharges. The plasma focus has extensively been studied as neutron producer, including its possibility to play a role in nuclear fusion. It was also researched not only for basic plasma studies, but also for other important applications. Conception, design, construction and study of devices and diagnostics suitable for each application have been made on basis of developed criteria

  12. Characterization of the axial plasma shock in a table top plasma focus after the pinch and its possible application to testing materials for fusion reactors

    Energy Technology Data Exchange (ETDEWEB)

    Soto, Leopoldo, E-mail: lsoto@cchen.cl; Pavez, Cristian; Moreno, José [Comisión Chilena de Energía Nuclear, Casilla 188-D, Santiago (Chile); Centro de Investigación y Aplicaciones en Física de Plasmas y Potencia Pulsada, P" 4, Santiago-Talca (Chile); Departamento de Ciencias Físicas, Facultad de Ciencias Exactas, Universidad Andrés Bello, República 220, Santiago (Chile); Inestrosa-Izurieta, María José [Comisión Chilena de Energía Nuclear, Casilla 188-D, Santiago (Chile); Centro de Investigación y Aplicaciones en Física de Plasmas y Potencia Pulsada, P" 4, Santiago-Talca (Chile); Veloso, Felipe [Instituto de Física, Pontificia Universidad Católica de Chile, Santiago (Chile); Gutiérrez, Gonzalo [Departamento de Física, Facultad de Ciencias, Universidad de Chile, Santiago (Chile); Vergara, Julio [Facultad de Ingeniería, Pontificia Universidad Católica de Chile, Santiago (Chile); Clausse, Alejandro [CNEA-CONICET and Universidad Nacional del Centro, 7000 Tandil (Argentina); Bruzzone, Horacio [CONICET and Universidad de Mar del Plata, Mar del Plata (Argentina); Castillo, Fermín [Instituto de Ciencias Físicas, Universidad Nacional Autónoma de México, Cuernavaca, Morelos (Mexico); and others

    2014-12-15

    The characterization of plasma bursts produced after the pinch phase in a plasma focus of hundreds of joules, using pulsed optical refractive techniques, is presented. A pulsed Nd-YAG laser at 532 nm and 8 ns FWHM pulse duration was used to obtain Schlieren images at different times of the plasma dynamics. The energy, interaction time with a target, and power flux of the plasma burst were assessed, providing useful information for the application of plasma focus devices for studying the effects of fusion-relevant pulses on material targets. In particular, it was found that damage factors on targets of the order of 10{sup 4} (W/cm{sup 2})s{sup 1/2} can be obtained with a small plasma focus operating at hundred joules.

  13. Characterization of the axial plasma shock in a table top plasma focus after the pinch and its possible application to testing materials for fusion reactors

    International Nuclear Information System (INIS)

    4, Santiago-Talca (Chile); Departamento de Ciencias Físicas, Facultad de Ciencias Exactas, Universidad Andrés Bello, República 220, Santiago (Chile))" data-affiliation=" (Comisión Chilena de Energía Nuclear, Casilla 188-D, Santiago (Chile); Centro de Investigación y Aplicaciones en Física de Plasmas y Potencia Pulsada, P4, Santiago-Talca (Chile); Departamento de Ciencias Físicas, Facultad de Ciencias Exactas, Universidad Andrés Bello, República 220, Santiago (Chile))" >Soto, Leopoldo; 4, Santiago-Talca (Chile); Departamento de Ciencias Físicas, Facultad de Ciencias Exactas, Universidad Andrés Bello, República 220, Santiago (Chile))" data-affiliation=" (Comisión Chilena de Energía Nuclear, Casilla 188-D, Santiago (Chile); Centro de Investigación y Aplicaciones en Física de Plasmas y Potencia Pulsada, P4, Santiago-Talca (Chile); Departamento de Ciencias Físicas, Facultad de Ciencias Exactas, Universidad Andrés Bello, República 220, Santiago (Chile))" >Pavez, Cristian; 4, Santiago-Talca (Chile); Departamento de Ciencias Físicas, Facultad de Ciencias Exactas, Universidad Andrés Bello, República 220, Santiago (Chile))" data-affiliation=" (Comisión Chilena de Energía Nuclear, Casilla 188-D, Santiago (Chile); Centro de Investigación y Aplicaciones en Física de Plasmas y Potencia Pulsada, P4, Santiago-Talca (Chile); Departamento de Ciencias Físicas, Facultad de Ciencias Exactas, Universidad Andrés Bello, República 220, Santiago (Chile))" >Moreno, José; 4, Santiago-Talca (Chile))" data-affiliation=" (Comisión Chilena de Energía Nuclear, Casilla 188-D, Santiago (Chile); Centro de Investigación y Aplicaciones en Física de Plasmas y Potencia Pulsada, P4, Santiago-Talca (Chile))" >Inestrosa-Izurieta, María José; Veloso, Felipe; Gutiérrez, Gonzalo; Vergara, Julio; Clausse, Alejandro; Bruzzone, Horacio; Castillo, Fermín

    2014-01-01

    The characterization of plasma bursts produced after the pinch phase in a plasma focus of hundreds of joules, using pulsed optical refractive techniques, is presented. A pulsed Nd-YAG laser at 532 nm and 8 ns FWHM pulse duration was used to obtain Schlieren images at different times of the plasma dynamics. The energy, interaction time with a target, and power flux of the plasma burst were assessed, providing useful information for the application of plasma focus devices for studying the effects of fusion-relevant pulses on material targets. In particular, it was found that damage factors on targets of the order of 10 4 (W/cm 2 )s 1/2 can be obtained with a small plasma focus operating at hundred joules

  14. Simulation of electrical discharge in a 3.6 Joule miniature plasma focus device using SIMULINK

    International Nuclear Information System (INIS)

    Jafari, H.; Habibi, M.

    2014-01-01

    A novel technique has been developed and studied in this paper to simulate the electrical discharge circuit of a 3.6 J miniature plasma focus device (PFD) and investigate the effect of inductance variation on voltage spike and current dip. The technique is based on a correlation between the electrical discharge circuit and plasma dynamics in a very small PFD that operates at the energy of 3.6 J. The simulation inputs include the charging voltage, capacitor bank capacitance, current limiter resistance, bypass resistance as well as the time-dependent inductance and resistance of the plasma sheath which are calculated by assuming the plasma dynamics as transit times in going from one phase to the next. The variations of the most important elements in the circuit (i.e. the constant and breakdown inductances) and their effects on the current dip are studied in PFDs with low and high constant inductance. The model demonstrated for achieving a good pinch in the PFD, although the total inductance of the system should be low; however there is always an optimum inductance which causes an appropriate pinch. Furthermore, the electrical power produced by the pulsed power supply, the mechanical energy as well as the magnetic energy which are transferred into the plasma tube were obtained from simulation. The graph of electrical power demonstrated a high instantaneous increment in the power transferred into the plasma as one of the greatest advantages of the pulsed power supply. The simulation was performed using software tools within the MATLAB/SIMULINK simulation environment. The PFD, generating neutrons in the range of 10 6 to 10 10 neutrons per pulse will have substantial use in the physics and engineering applications. (authors)

  15. Plasma sheath dynamics and parameters in focus and defocus conditions. Vol. 2

    International Nuclear Information System (INIS)

    Masoud, M.M.; Soliman, H.M.; El-Aragi, G.M.

    1996-01-01

    The study deals with the effect of the inner electrode polarity on the dynamic behaviour and parameters of plasma sheath in a coaxial discharge. The experimental investigations presented here were carried out in a coaxial plasma focus discharge device of mather geometry. It consisted of coaxial stainless steel hollow cylindrical electrodes with inner electrode 18.2 cm length and outer-electrode 31.5 cm length. The diameter of the inner and outer electrodes are 3.2 cm and 6.6 cm, respectively. The two electrodes are separated by a teflon disc at the breech. The outer electrode muzzle is connected to stainless steel expansion chamber of 23 cm length and 17 cm diameter. The discharge takes place in hydrogen gas with a base pressure of 1 torr. The experiments were conducted with 10 kV bank voltage, which corresponds to 100 K A peak discharge current. By using a double electric probe, It was found that the plasma electron density was higher near the negative electrode. Investigations using a miniature rogovsky coil have shown that, the radial and azimuthal current density increased with radial distance from negative electrode to positive electrode. The shape and the axial velocity of plasma sheath were measured using a magnetic probe. The experimental results indicate that, the plasma is thick near the negative electrode, in both cases of the outer or the inner electrode. Also it has been found that the axial plasma sheath velocity reaches its maximum value at the muzzle for positive and negative inner electrode. The magnitude of maximum axial velocity reaches 1.7 x 10 60 cm/s for positive inner electrode and decreased by 25% for negative inner electrode further investigations revealed that on interchanging the polarity from normal operation (positive inner electrode), it was found that with negative inner electrode the soft x-ray emission intensity dropped by three orders of magnitude from that with positive inner electrode. 9 figs

  16. Plasma sheath dynamics and parameters in focus and defocus conditions. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Masoud, M M; Soliman, H M; El-Aragi, G M [Plasma Physics and Nuclear Fusion Department, Nuclear Research Centre, Atomic Energy Aurhority, Cairo (Egypt)

    1996-03-01

    The study deals with the effect of the inner electrode polarity on the dynamic behaviour and parameters of plasma sheath in a coaxial discharge. The experimental investigations presented here were carried out in a coaxial plasma focus discharge device of mather geometry. It consisted of coaxial stainless steel hollow cylindrical electrodes with inner electrode 18.2 cm length and outer-electrode 31.5 cm length. The diameter of the inner and outer electrodes are 3.2 cm and 6.6 cm, respectively. The two electrodes are separated by a teflon disc at the breech. The outer electrode muzzle is connected to stainless steel expansion chamber of 23 cm length and 17 cm diameter. The discharge takes place in hydrogen gas with a base pressure of 1 torr. The experiments were conducted with 10 kV bank voltage, which corresponds to 100 K A peak discharge current. By using a double electric probe, It was found that the plasma electron density was higher near the negative electrode. Investigations using a miniature rogovsky coil have shown that, the radial and azimuthal current density increased with radial distance from negative electrode to positive electrode. The shape and the axial velocity of plasma sheath were measured using a magnetic probe. The experimental results indicate that, the plasma is thick near the negative electrode, in both cases of the outer or the inner electrode. Also it has been found that the axial plasma sheath velocity reaches its maximum value at the muzzle for positive and negative inner electrode. The magnitude of maximum axial velocity reaches 1.7 x 10{sup 60} cm/s for positive inner electrode and decreased by 25% for negative inner electrode further investigations revealed that on interchanging the polarity from normal operation (positive inner electrode), it was found that with negative inner electrode the soft x-ray emission intensity dropped by three orders of magnitude from that with positive inner electrode. 9 figs.

  17. Kinetic Simulations of the Self-Focusing and Dissipation of Finite-Width Electron Plasma Waves

    Energy Technology Data Exchange (ETDEWEB)

    Winjum, B. J. [Univ. of California, Los Angeles, CA (United States); Berger, R. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chapman, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Banks, J. W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brunner, S. [Federal Inst. of Technology, Lausanne (Switzerland)

    2013-09-01

    Two-dimensional simulations, both Vlasov and particle-in-cell, are presented that show the evolution of the field and electron distribution of finite-width, nonlinear electron plasma waves. The intrinsically intertwined effects of self-focusing and dissipation of field energy caused by electron trapping are studied in simulated systems that are hundreds of wavelengths long in the transverse direction but only one wavelength long and periodic in the propagation direction. From various initial wave states, both the width at focus Δm relative to the initial width Δ0 and the maximum field amplitude at focus are shown to be a function of the growth rate of the transverse modulational instability γTPMI divided by the loss rate of field energy νE to electrons escaping the trapping region. With dissipation included, an amplitude threshold for self-focusing γTPMIE~1 is found that supports the analysis of Rose [Phys. Plasmas 12, 012318 (2005)].

  18. Plasma and Muscle Myostatin in Relation to Type 2 Diabetes

    Science.gov (United States)

    Brandt, Claus; Nielsen, Anders R.; Fischer, Christian P.; Hansen, Jakob; Pedersen, Bente K.; Plomgaard, Peter

    2012-01-01

    Objective Myostatin is a secreted growth factor expressed in skeletal muscle tissue, which negatively regulates skeletal muscle mass. Recent animal studies suggest a role for myostatin in insulin resistance. We evaluated the possible metabolic role of myostatin in patients with type 2 diabetes and healthy controls. Design 76 patients with type 2 diabetes and 92 control subjects were included in the study. They were matched for age, gender and BMI. Plasma samples and biopsies from the vastus lateralis muscle were obtained to assess plasma myostatin and expression of myostatin in skeletal muscle. Results Patients with type 2 diabetes had higher fasting glucose (8.9 versus 5.1 mmol/L, Pmyostatin mRNA content than the control subjects. Plasma myostatin concentrations did not differ between patients with type 2 diabetes and controls. In healthy controls, muscle myostatin mRNA correlated with HOMA2-IR (r = 0.30, Pmyostatin may have a negative effect on metabolism. However, the metabolic effect of myostatin appears to be overruled by other factors in patients with type 2 diabetes. PMID:22615949

  19. Simulations of a dense plasma focus on a high impedance generator

    Science.gov (United States)

    Beresnyak, Andrey; Giuliani, John; Jackson, Stuart; Richardson, Steve; Swanekamp, Steve; Schumer, Joe; Commisso, Robert; Mosher, Dave; Weber, Bruce; Velikovich, Alexander

    2017-10-01

    We study the connection between plasma instabilities and fast ion acceleration for neutron production on a Dense Plasma Focus (DPF). The experiments will be performed on the HAWK generator (665 kA), which has fast rise time, 1.2 μs, and a high inductance, 607 nH. It is hypothesized that high impedance may enhance the neutron yield because the current will not be reduced during the collapse resulting in higher magnetization. To prevent upstream breakdown, we will inject plasma far from the insulator stack. We simulated rundown and collapse dynamics with Athena - Eulerian 3D, unsplit finite volume MHD code that includes shock capturing with Riemann solvers, resistive diffusion and the Hall term. The simulations are coupled to an equivalent circuit model for HAWK. We will report the dynamics and implosion time as a function of the initial injected plasma distribution and the implications of non-ideal effects. We also traced test particles in MHD fields and confirmed the presence of stochastic acceleration, which was limited by the size of the system and the strength of the magnetic field. Supported by DOE/NNSA and the Naval Research Laboratory Base Program.

  20. Pulsed neutron generators based on plasma focus devices of low energy

    International Nuclear Information System (INIS)

    Silva, Patricio; Moreno, Jose; Soto, Leopoldo

    2003-01-01

    The plasma focus is a pulsed neutron source especially suited for applications because it reduces the danger of contamination of conventional isotopic radioactive sources. As first stage of a program to design a repetitive pulsed neutron generator for industrial applications we constructed two very small plasma focus operating at an energy level of the order of a) tens of joules (PF-50J, 160nF capacitor bank, 20-35 kV, 32-100J, ∼150ns first quarter of period) and b) hundred of joules (PF-400J, 880nF, 20-35kV, 176-539J, ∼300ns first quarter of period). In this article we present results related to design and construction of these small plasma foci (PF-50J and PF-400J). Neutron yield vs. deuterium. pressure has been obtained, a maximum emission of the order of 7x10 4 and 10 6 neutrons per shot has been measured in the PF-50J and PF-400J respectively (author)

  1. Filamentary structures in dense plasma focus: Current filaments or vortex filaments?

    Energy Technology Data Exchange (ETDEWEB)

    Soto, Leopoldo, E-mail: lsoto@cchen.cl; Pavez, Cristian; Moreno, José [Comisión Chilena de Energía Nuclear, CCHEN, Casilla 188-D, Santiago (Chile); Center for Research and Applications in Plasma Physics and Pulsed Power, P4, Departamento de Ciencias Físicas, Facultad de Ciencias Exactas, Universidad Andrés Bello, República 220, Santiago (Chile); Castillo, Fermin [Universidad Nacional Autónoma de México, Cuernavaca, México (Mexico); Veloso, Felipe [Instituto de Física, Pontificia Universidad Católica de Chile, 7820436 Santiago (Chile); Auluck, S. K. H. [Bhabha Atomic Research Center, Mumbai 400 085 (India)

    2014-07-15

    Recent observations of an azimuthally distributed array of sub-millimeter size sources of fusion protons and correlation between extreme ultraviolet (XUV) images of filaments with neutron yield in PF-1000 plasma focus have re-kindled interest in their significance. These filaments have been described variously in literature as current filaments and vortex filaments, with very little experimental evidence in support of either nomenclature. This paper provides, for the first time, experimental observations of filaments on a table-top plasma focus device using three techniques: framing photography of visible self-luminosity from the plasma, schlieren photography, and interferometry. Quantitative evaluation of density profile of filaments from interferometry reveals that their radius closely agrees with the collision-less ion skin depth. This is a signature of relaxed state of a Hall fluid, which has significant mass flow with equipartition between kinetic and magnetic energy, supporting the “vortex filament” description. This interpretation is consistent with empirical evidence of an efficient energy concentration mechanism inferred from nuclear reaction yields.

  2. External circuit integration with electromagnetic particle in cell modeling of plasma focus devices

    International Nuclear Information System (INIS)

    Seng, Y. S.; Lee, P.; Rawat, R. S.

    2015-01-01

    The pinch performance of a plasma focus (PF) device is sensitive to the physical conditions of the breakdown phase. It is therefore essential to model and study the initial phase in order to optimize device performance. An external circuit is self consistently coupled to the electromagnetic particle in cell code to model the breakdown and initial lift phase of the United Nations University/International Centre for Theoretical Physics (UNU-ICTP) plasma focus device. Gas breakdown during the breakdown phase is simulated successfully, following a drop in the applied voltage across the device and a concurrent substantial rise in the circuit current. As a result, the plasma becomes magnetized, with the growing value of the magnetic field over time leading to the gradual lift off of the well formed current sheath into the axial acceleration phase. This lifting off, with simultaneous outward sheath motion along the anode and vertical cathode, and the strong magnetic fields in the current sheath region, was demonstrated in this work, and hence validates our method of coupling the external circuit to PF devices. Our method produces voltage waveforms that are qualitatively similar to the observed experimental voltage profiles of the UNU-ICTP device. Values of the mean electron energy before and after voltage breakdown turned out to be different, with the values after breakdown being much lower. In both cases, the electron energy density function turned out to be non-Maxwellian

  3. Designing Neutralized Drift Compression for Focusing of Intense Ion Beam Pulses in a Background Plasma

    International Nuclear Information System (INIS)

    Kaganovich, I.D.; Davidson, R.C.; Dorf, M.; Startsev, E.A.; Barnard, J.J.; Friedman, A.; Lee, E.P.; Lidia, S.M.; Logan, B.G.; Roy, P.K.; Seidl, P.A.; Welch, D.R.; Sefkow, A.B.

    2009-01-01

    Neutralized drift compression offers an effective method for particle beam focusing and current amplification. In neutralized drift compression, a linear radial and longitudinal velocity drift is applied to a beam pulse, so that the beam pulse compresses as it drifts in the drift-compression section. The beam intensity can increase more than a factor of 100 in both the radial and longitudinal directions, resulting in more than 10,000 times increase in the beam number density during this process. The self-electric and self-magnetic fields can prevent tight ballistic focusing and have to be neutralized by supplying neutralizing electrons. This paper presents a survey of the present theoretical understanding of the drift compression process and plasma neutralization of intense particle beams. The optimal configuration of focusing and neutralizing elements is discussed in this paper.

  4. Focus on strongly correlated quantum fluids: from ultracold quantum gases to QCD plasmas Focus on strongly correlated quantum fluids: from ultracold quantum gases to QCD plasmas

    Science.gov (United States)

    Adams, Allan; Carr, Lincoln D.; Schaefer, Thomas; Steinberg, Peter; Thomas, John E.

    2013-04-01

    The last few years have witnessed a dramatic convergence of three distinct lines of research concerned with different kinds of extreme quantum matter. Two of these involve new quantum fluids that can be studied in the laboratory, ultracold quantum gases and quantum chromodynamics (QCD) plasmas. Even though these systems involve vastly different energy scales, the physical properties of the two quantum fluids are remarkably similar. The third line of research is based on the discovery of a new theoretical tool for investigating the properties of extreme quantum matter, holographic dualties. The main goal of this focus issue is to foster communication and understanding between these three fields. We proceed to describe each in more detail. Ultracold quantum gases offer a new paradigm for the study of nonperturbative quantum many-body physics. With widely tunable interaction strength, spin composition, and temperature, using different hyperfine states one can model spin-1/2 fermions, spin-3/2 fermions, and many other spin structures of bosons, fermions, and mixtures thereof. Such systems have produced a revolution in the study of strongly interacting Fermi systems, for example in the Bardeen-Cooper-Schrieffer (BCS) to Bose-Einstein condensate (BEC) crossover region, where a close collaboration between experimentalists and theorists—typical in this field—enabled ground-breaking studies in an area spanning several decades. Half-way through this crossover, when the scattering length characterizing low-energy collisions diverges, one obtains a unitary quantum gas, which is universal and scale invariant. The unitary gas has close parallels in the hydrodynamics of QCD plasmas, where the ratio of viscosity to entropy density is extremely low and comparable to the minimum viscosity conjecture, an important prediction of AdS/CFT (see below). Exciting developments in the thermodynamic and transport properties of strongly interacting Fermi gases are of broad

  5. Fields of an ultrashort tightly focused radially polarized laser pulse in a linear response plasma

    Science.gov (United States)

    Salamin, Yousef I.

    2017-10-01

    Analytical expressions for the fields of a radially polarized, ultrashort, and tightly focused laser pulse propagating in a linear-response plasma are derived and discussed. The fields are obtained from solving the inhomogeneous wave equations for the vector and scalar potentials, linked by the Lorenz gauge, in a plasma background. First, the scalar potential is eliminated using the gauge condition, then the vector potential is synthesized from Fourier components of an initial uniform distribution of wavenumbers, and the inverse Fourier transformation is carried out term-by-term in a truncated series (finite sum). The zeroth-order term in, for example, the axial electric field component is shown to model a pulse much better than its widely used paraxial approximation counterpart. Some of the propagation characteristics of the fields are discussed and all fields are shown to have manifested the expected limits for propagation in a vacuum.

  6. Time and space resolved observation of hot spots in a plasma focus

    International Nuclear Information System (INIS)

    Choi, P.; Aliaga, R.; Herold, H.

    1990-01-01

    The authors report some recent results on the time and space evolution of hot spots on the DPF-78 plasma focus at the University of Stuttgart. The experiments were carried out in mixtures of deuterium and krypton at a bank voltage of 60 kV and a stored energy of 28 kJ. A modification of the ADRRM streak technique carried out in the soft x-ray region allowed us to directly examine some characteristics of the hot spots. Simultaneous measurements were carried out on the hard x-ray radiation (80 keV), the spatially resolved optical emissions, the neutron yield rate with TOF information and the plasma and bank currents

  7. DLC coating on stainless steel by pulsed methane discharge in repetitive plasma focus

    International Nuclear Information System (INIS)

    Hassan, M.; Qayyum, A.; Ahmad, S.; Mahmood, S.; Shafiq, M.; Zakaullah, M.; Lee, P.; Rawat, R.S.

    2014-01-01

    Amorphous hydrogenated carbon (a-C:H)/diamond-like carbon (DLC) coatings have been achieved on AISI 304 stainless steel (SS) substrates by employing energetic ions emitted from a repetitive plasma focus operated in CH 4 discharge. The Raman spectroscopy of the coatings exhibits the evolution of a-C:H/DLC coatings with clearly observed D and G peaks centered about 1320–1360 and 1560–1620 cm −1 respectively. The diamond character of the coatings is influenced by the ion flux and repetition rate of the focus device. The repetitive discharge mode of plasma focus has led to the formation of a-C:H/DLC coatings in short duration of time. The coatings transform from a-C to a-C:H depending upon substrate angular position. X-ray diffraction (XRD) analysis confirms the formation of DLC coating owing to stress-induced restructuring in SS. The estimated crystallite size is found to be ∼40–50 nm. Field emission scanning electron micrographs exhibit a layered granular surface morphology of the coatings. The Vickers surface hardness of the DLC coated SS samples has been significantly improved.

  8. DLC coating on stainless steel by pulsed methane discharge in repetitive plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, M., E-mail: hassanjh@gmail.com [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University, BLK7, 1 Nanyang Walk, Singapore 637616 (Singapore); Qayyum, A.; Ahmad, S. [National Tokamak Fusion Program, 3329 Islamabad (Pakistan); Mahmood, S. [Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University, BLK7, 1 Nanyang Walk, Singapore 637616 (Singapore); Department of Physics, University of Karachi, 75270 Karachi (Pakistan); Shafiq, M.; Zakaullah, M. [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Lee, P.; Rawat, R.S. [Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University, BLK7, 1 Nanyang Walk, Singapore 637616 (Singapore)

    2014-06-01

    Amorphous hydrogenated carbon (a-C:H)/diamond-like carbon (DLC) coatings have been achieved on AISI 304 stainless steel (SS) substrates by employing energetic ions emitted from a repetitive plasma focus operated in CH{sub 4} discharge. The Raman spectroscopy of the coatings exhibits the evolution of a-C:H/DLC coatings with clearly observed D and G peaks centered about 1320–1360 and 1560–1620 cm{sup −1} respectively. The diamond character of the coatings is influenced by the ion flux and repetition rate of the focus device. The repetitive discharge mode of plasma focus has led to the formation of a-C:H/DLC coatings in short duration of time. The coatings transform from a-C to a-C:H depending upon substrate angular position. X-ray diffraction (XRD) analysis confirms the formation of DLC coating owing to stress-induced restructuring in SS. The estimated crystallite size is found to be ∼40–50 nm. Field emission scanning electron micrographs exhibit a layered granular surface morphology of the coatings. The Vickers surface hardness of the DLC coated SS samples has been significantly improved.

  9. Plasma osteoprotegerin concentrations in peripheral sensory neuropathy in Type 1 and Type 2 diabetic patients

    DEFF Research Database (Denmark)

    Nybo, M; Poulsen, M K; Grauslund, J

    2010-01-01

    Osteoprotegerin (OPG) has been linked to different diabetes complications, including cardiovascular disease, and new findings have indicated a specific role in diabetic peripheral neuropathy, but the exact mechanism is unknown. To investigate a possible association between OPG and diabetic...... peripheral sensory neuropathy, we therefore analysed plasma OPG in Type 1 and Type 2 diabetic patients with and without peripheral neuropathy....

  10. Assessment of image quality in x-ray radiography imaging using a small plasma focus device

    International Nuclear Information System (INIS)

    Kanani, A.; Shirani, B.; Jabbari, I.; Mokhtari, J.

    2014-01-01

    This paper offers a comprehensive investigation of image quality parameters for a small plasma focus as a pulsed hard x-ray source for radiography applications. A set of images were captured from some metal objects and electronic circuits using a low energy plasma focus at different voltages of capacitor bank and different pressures of argon gas. The x-ray source focal spot of this device was obtained to be about 0.6 mm using the penumbra imaging method. The image quality was studied by several parameters such as image contrast, line spread function (LSF) and modulation transfer function (MTF). Results showed that the contrast changes by variations in gas pressure. The best contrast was obtained at a pressure of 0.5 mbar and 3.75 kJ stored energy. The results of x-ray dose from the device showed that about 0.6 mGy is sufficient to obtain acceptable images on the film. The measurements of LSF and MTF parameters were carried out by means of a thin stainless steel wire 0.8 mm in diameter and the cut-off frequency was obtained to be about 1.5 cycles/mm. - Highlights: • We investigated a small plasma focus as pulsed x-ray source for radiography applications. • The image quality was studied by several parameters such as image contrast, LSF and MTF. • The x-ray source focal spot was obtained to be ∼0.6 mm using the penumbra imaging method. • The x-ray dose measurement showed that about 0.6 mGy is sufficient to obtain acceptable images on the film. • The profiles of LSF and MTF showed that the cut-off frequency is about 1.5 cycles/mm

  11. Operational characteristics of a high voltage plasma focus device working with deuterium and heavy gas mixture

    International Nuclear Information System (INIS)

    Zoita, V.; Presura, R.; Gherendi, F.; Dumitrescu-Zoita, C.; Aliaga, R.

    1992-01-01

    The addition of a few neon percents to the deuterium gas filling of a medium energy plasma focus device (PFD) changes dramatically the radiation characteristics of the discharge as well as the pinch configuration. One exceptional result is the generation of high aspect ratio pinches shown clearly and reproducibly on X-ray pinhole camera images and on schlieren pictures. Another remarkable result is that these pinches which show no macroscopic instabilities copiously produce neutrons and hard X-rays. This confirms an experimental fact previously identified on a lower voltage PFD: the macroscopic instabilities do not play the decisive role in the neutronic performance of medium energy PFD's. (Author)

  12. Two-dimensional magnetohydrodynamic calculations for a 5 MJ plasma focus

    International Nuclear Information System (INIS)

    Maxon, S.

    1983-01-01

    This article describes the calculation of the performance of a 5 MJ plasma focus using a two-dimensional magnetohydrodynamic (2-D MHD) code. Discusses two configurations, a solid and a hollow anode. Finds an instability in the current sheath of the hollow anode which has the characteristics of the short wave length sausage instability. As the current sheath reaches the axis, the numerical solution is seen to break down. When the numerical solution breaks down, the code shows a splitting of the current sheath (from the axis to the anode) and the loss of a large amount of magnetic energy. Current-sheath stagnation is observed in the hollow anode configuration

  13. Self-focusing of a non-Gaussian laser mode in a dense plasma

    International Nuclear Information System (INIS)

    Nayyar, V.P.

    1978-01-01

    This paper presents a study of the self-focusing of a high-power non-Gaussian laser beam operating in TEM 01 mode in a strongly ionized plasma. The nonlinearity in the dielectric constant is caused by the nonuniform redistribution of carriers due to their inhomogeneous heating by the laser beam having transverse variation of intensity along its wave front. It is found that when the power of the beam exceeds the critical power, focusing effects are observed in the Y direction, whereas divergence of the beam takes place in the X direction. In the reverse case (when P 2 first increases in the Y direction, after penetrating a certain depth it reaches a broadened maxima and then starts decreasing with the distance of propagation inside the medium. The beam continues diverging in the X direction. It has also been found that absorption brings about a reduction in the extent of self-focusing. When the absorption length is less than the self-focusing length appreciable self-focusing does not take place

  14. Development of the dense plasma focus for short-pulse applications

    Science.gov (United States)

    Bennett, N.; Blasco, M.; Breeding, K.; Constantino, D.; DeYoung, A.; DiPuccio, V.; Friedman, J.; Gall, B.; Gardner, S.; Gatling, J.; Hagen, E. C.; Luttman, A.; Meehan, B. T.; Misch, M.; Molnar, S.; Morgan, G.; O'Brien, R.; Robbins, L.; Rundberg, R.; Sipe, N.; Welch, D. R.; Yuan, V.

    2017-01-01

    The dense plasma focus (DPF) has long been considered a compact source for pulsed neutrons and has traditionally been optimized for the total neutron yield. In this paper, we describe the efforts to optimize the DPF for short-pulse applications by introducing a reentrant cathode at the end of the coaxial plasma gun. The resulting neutron pulse widths are reduced by an average of 21 ±9 % from the traditional long-drift DPF design. Pulse widths and yields achieved from deuterium-tritium fusion at 2 MA are 61.8 ±30.7 ns FWHM and 1.84 ±0.49 ×1012 neutrons per shot. Simulations were conducted concurrently to elucidate the DPF operation and confirm the role of the reentrant cathode. A hybrid fluid-kinetic particle-in-cell modeling capability demonstrates correct sheath velocities, plasma instabilities, and fusion yield rates. Consistent with previous findings that the DPF is dominated by beam-target fusion from superthermal ions, we estimate that the thermonuclear contribution is at the 1% level.

  15. Plasma focus neutron anisotropy measurements and influence of a deuteron beam obstacle

    Energy Technology Data Exchange (ETDEWEB)

    Talebitaher, A. [Physics Department, University of Regina, Saskatchewan, Canada S4S 0A2 (Canada); Springham, S.V., E-mail: stuart.springham@nie.edu.sg [Natural Sciences and Science Education, National Institute of Education, 637616 (Singapore); Rawat, R.S.; Lee, P. [Natural Sciences and Science Education, National Institute of Education, 637616 (Singapore)

    2017-03-11

    The deuterium-deuterium (DD) fusion neutron yield and anisotropy were measured on a shot-to-shot basis for the NX2 plasma focus (PF) device using two beryllium fast-neutron activation detectors at 0° and 90° to the PF axis. Measurements were performed for deuterium gas pressures in the range 6–16 mbar, and positive correlations between neutron yield and anisotropy were observed at all pressures. Subsequently, at one deuterium gas pressure (13 mbar), the contribution to the fusion yield produced by the forwardly-directed D{sup +} ion beam, emitted from the plasma pinch, was investigated by using a circular Pyrex plate to obstruct the beam and suppress its fusion contribution. Neutron measurements were performed with the obstacle positioned at two distances from the anode tip, and also without the obstacle. It was found that ~ 80% of the neutron yield originates in the plasma pinch column and just above that. In addition, proton pinhole imaging was performed from the 0° and 90° directions to the pinch. The obtained proton images are consistent with the conclusion that DD fusion is concentrated (~ 80%) in the pinch column region.

  16. Limits of deuterium pressure range with neutron production in plasma focus devices

    International Nuclear Information System (INIS)

    Pouzo, J.; Milanese, M.; Piriz, R.; Cortazar, D.; Moroso, R.

    1988-01-01

    In this work we present the experimental curves of neutron yield (Y) respect to the deuterium filling pressure (p) obtained in our plasma focuses device PACO. Y increases with the focus current (I f ) according with the scaling law Y ∼I 4-5 f , but it presents a limited range of p beyond which Y drastically decreases. The higher pressure limit is coincident with recently reported limit due to the energy available to maintain the ionization rate of the neutral gas during the roll-off stage. The lower pressure limit is here explained, through experimental evidences, in terms of a phenomenon connected with the dynamics of the current sheath (cs) during the roll-off stage. (author). 8 refs, 11 figs

  17. Characterization of light ion beams generated by a plasma focus device

    International Nuclear Information System (INIS)

    Koo, Bon Cheul

    1999-02-01

    Plasma focus device has been studied as neutron and X-ray sources generated from the high pressure fusion reaction during Z-pinch. Recently, the scope of the device is focused on efficient neutron generation, X-ray lithography, preliminary fusion experiment, and ion/electron beam generation devices. A Hexagonal Beam Generator with six parallel capacitors has been developed and generated ion beams from 30kJ(C=6 μ F, V= 100kV) maximum energy. To find the optimum condition of ion beam generation, the correlation among charging voltage(20∼30kV), operation pressure of chamber(0.1∼5 torr), and length of electrode has been studied. To measure ion beam, a Faraday Cup and 3 Rogowski coils were installed. Energy of ion beam was obtained by adopting time-of -flight method between Rogowski coils

  18. Hot electron spatial distribution under presence of laser light self-focusing in over-dense plasmas

    International Nuclear Information System (INIS)

    Tanimoto, T; Yabuuchi, T; Habara, H; Kondo, K; Kodama, R; Mima, K; Tanaka, K A; Lei, A L

    2008-01-01

    In fast ignition for laser thermonuclear fusion, an ultra intense laser (UIL) pulse irradiates an imploded plasma in order to fast-heat a high-density core with hot electrons generated in laser-plasma interactions. An UIL pulse needs to make plasma channel via laser self-focusing and to propagate through the corona plasma to reach close enough to the core. Hot electrons are used for heating the core. Therefore the propagation of laser light in the high-density plasma region and spatial distribution of hot electron are important in issues in order to study the feasibility of this scheme. We measure the spatial distribution of hot electron when the laser light propagates into the high-density plasma region by self-focusing

  19. Nitriding of Ti substrate using energetic ions from plasma focus device

    International Nuclear Information System (INIS)

    Henriquez, A; Bhuyan, H; Favre, M; Bora, B; Wyndham, E; Chuaqui, H; Mändl, S; Gerlach, J W; Manova, D

    2012-01-01

    Plasma Focus (PF) discharge is a pulsed plasma producing discharge that generates high temperature and high density plasma for a short duration. PF devices are known to emit intense ion beams pulses of characteristic energy in the keV to a few MeV range, in a time scale of tens of nanoseconds. We have previously investigated the ion flux and energy spectrum of ion beams emitted from a low energy PF, operating at 20 kV, with 1.8 kJ stored energy. It was observed that the ion beams have wide range of energy and intensity spectra with a clear angular anisotropy. Due to the wide range of ion energy and intensity spectra PF has become a subject of current interest for its applications in material sciences including surface modification and thin film deposition. The purpose of this study is the formation of titanium nitride (TiN) thin film and to investigate the structural properties of the TiN thin films in terms of PF angular positions. Substrates like Ti and Ti/Si were nitrided in a 1.8 kJ PF device at different angular positions with respect to the PF axis in order to correlate their surface properties with ion beam parameters. Preliminary characterizations of the ion implanted substrates have been conducted, using SEM, EDX and XRD. Our results indicate the formation of nanocrystalline TiN thin film only in certain angular positions. Angular dependency of the surface morphology was observed, which shows that the surface features strongly depends on ion beam energy and flux. With increasing angular positions, a reduction in the deposition rate and the sputter rate is observed. A pronounced nanostructured surface is only observed at the axis of the pinched plasma column, indicating the dominant role of sputtering and perhaps melting and fast re-crystallization of the surface in creating the nanostructures.

  20. Study of the thermal effect on silicon surface induced by ion beam from plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Z., E-mail: pscientific5@aec.org.sy [Scientific Service Department, Atomic Energy Commission of Syria, P.O. Box: 6091, Damascus (Syrian Arab Republic); Ahmad, M. [IBA Laboratory, Atomic Energy Commission of Syria, P.O. Box: 6091, Damascus (Syrian Arab Republic); Chemistry Department, Atomic Energy Commission of Syria, P.O. Box: 6091, Damascus (Syrian Arab Republic); Al-Hawat, Sh.; Akel, M. [Physics Department, Atomic Energy Commission of Syria, P.O. Box: 6091, Damascus (Syrian Arab Republic)

    2017-04-01

    Structural modifications in form of ripples and cracks are induced by nitrogen ions from plasma focus on silicon surface. The investigation of such structures reveals correlation between ripples and cracks formation in peripheral region of the melt spot. The reason of such correlation and structure formation is explained as result of thermal effect. Melting and resolidification of the center of irradiated area occur within one micro second of time. This is supported by a numerical simulation used to investigate the thermal effect induced by the plasma focus ion beams on the silicon surface. This simulation provides information about the temperature profile as well as the dynamic of the thermal propagation in depth and lateral directions. In accordance with the experimental observations, that ripples are formed in latter stage after the arrival of last ion, the simulation shows that the thermal relaxation takes place in few microseconds after the end of the ion beam arrival. Additionally, the dependency of thermal propagation and relaxation on the distance of the silicon surface from the anode is presented.

  1. Assessment of image quality in x-ray radiography imaging using a small plasma focus device

    Science.gov (United States)

    Kanani, A.; Shirani, B.; Jabbari, I.; Mokhtari, J.

    2014-08-01

    This paper offers a comprehensive investigation of image quality parameters for a small plasma focus as a pulsed hard x-ray source for radiography applications. A set of images were captured from some metal objects and electronic circuits using a low energy plasma focus at different voltages of capacitor bank and different pressures of argon gas. The x-ray source focal spot of this device was obtained to be about 0.6 mm using the penumbra imaging method. The image quality was studied by several parameters such as image contrast, line spread function (LSF) and modulation transfer function (MTF). Results showed that the contrast changes by variations in gas pressure. The best contrast was obtained at a pressure of 0.5 mbar and 3.75 kJ stored energy. The results of x-ray dose from the device showed that about 0.6 mGy is sufficient to obtain acceptable images on the film. The measurements of LSF and MTF parameters were carried out by means of a thin stainless steel wire 0.8 mm in diameter and the cut-off frequency was obtained to be about 1.5 cycles/mm.

  2. Synthesis of nanostructured multiphase Ti(C,N)/a-C films by a plasma focus device

    International Nuclear Information System (INIS)

    Ghareshabani, E.; Rawat, R.S.; Sobhanian, S.; Verma, R.; Karamat, S.; Pan, Z.Y.

    2010-01-01

    Nanostructured multiphase Ti(C,N)/a-C films were deposited using a 3.3 kJ pulsed plasma focus device onto silicon (1 0 0) substrates at room temperature. The plasma focus device, fitted with solid titanium anode instead of usual hollow copper anode, was operated with nitrogen and Ar/CH 4 as the filling gas. Films were deposited with different number of shots, at 80 mm from top of the anode and at zero angular position with respect to anode axis. X-ray diffraction results show the diffraction peaks related to different compounds such as TiC 2 , TiN, Ti 2 CN, Ti and TiC 0.62 confirming the deposition of multiphase titanium carbo-nitride composite films on silicon. X-ray photoelectron spectroscopy confirms the formation of Ti-C, C-N, Ti-N, Ti-O and C-C bonds in the films. Scanning electron microscopy reveals that the nanostructure grains are agglomerates of smaller nanoparticles about 10-20 nm in size. Raman studies verify the formation of multiphase Ti(C,N) and also of amorphous graphite in the films. The maximum microhardness value of the composite film is 14.8 ± 1.3 GPa for 30 shots.

  3. Study of the stacked plasma generator of Maecker type

    International Nuclear Information System (INIS)

    Shirai, Hiroyuki; Tabei, Katsuine; Machida, Ichiro; Ishihara, Kimio.

    1981-01-01

    An experimental investigation of a stacked plasma generator of Maecker type has been performed at low pressures (25 - 760 Torr) and low electric currents (10 - 60 A) for argon gas. Radial distributions of electron density and electron temperature were obtained by measuring the intensities of spectral lines and continuum from cylindrically confined plasmas. Based on such data of the macroscopic plasma parameters, the SAHA equilibrium relation, and the collisional and radiative theory of BATES et al., the spatial extent of equilibrium region and nonequilibrium effects of electronic excitation of the atom have been examined. In the plasmas generated in the apparatus, electron temperature ranged from 7,500 to 11,000 0 K and electron density 7 x 10 14 to 3 x 10 16 cm -3 . It was found that thermochemical equilibrium conditions existed only in the vicinity of the tube axis even at relatively high pressures and high currents, and the higher excited levels than the 5p level of argon atom were always in SAHA equilibrium with free electrons. (author)

  4. Self-Focusing of Quadruple Gaussian Laser Beam in an Inhomogenous Magnetized Plasma with Ponderomotive Non-Linearity: Effect of Linear Absorption

    International Nuclear Information System (INIS)

    Aggarwal, Munish; Vij, Shivani; Kant, Niti

    2015-01-01

    The propagation of quadruple Gaussian laser beam in a plasma characterized by axial inhomogeneity and nonlinearity due to ponderomotive force in the paraxial ray approximation is investigated. An appropriate expression for the nonlinear dielectric constant has been developed in the presence of external magnetic field, with linear absorption and due to saturation effects for arbitrary large intensity. The effects of different types of plasma axial inhomogeneities on self-focusing of laser beam have been studied with the typical laser and plasma parameters. Self-focusing of quadruple Gaussian laser beam in the presence of externally applied magnetic field and saturating parameter is found significantly improved in the case of extraordinary mode. Our results reveal that initially converging beam shows oscillatory convergence whereas initially diverging beam shows oscillatory divergence. The beam is more focussed at lower intensity in both cases viz. extraordinary and ordinary mode. (paper)

  5. Dynamics of 120 and 20 kV plasma focus devices with respect to density and current distribution, neutron and X-ray emission

    International Nuclear Information System (INIS)

    Decker, G.; Nahrath, B.; Oppenlaender, T.; Pross, G.; Rueckle, B.; Schmidt, H.; Shakhatre, M.; Trunk, M.

    1976-01-01

    Our experiments have aimed at two goals: 1) better understanding of the dynamics and neutron production of the focus phase and 2) improved scaling of the neutron yield by operating a high voltage focus. 1) For the first goal, experiments with a 30 kJ/ 16 kV plasma focus of the Mather type (NESSI) were performed. The simultaneously applied diagnostics include interferometry, X-ray photography with channel plates, magnetic probes and neutron emission. In the established chronology we can distinguish 5 phases in the development of the plasma focus: a compression phase is followed by a short (8 ns) very dense phase, where the density peaks at a minimum radius (t = 0 in our chronology). The plasma cylinder expands to a relatively long lasting (30 to 70 ns) quiescent phase before instabilities occur. This short unstable phase is followed by a decay phase during which the neutron emission peaks. Important correlations between the plasma parameters and the neutron emission are discussed. 2) Under the assumption that the neutron yield scales with a high power of the current, we concluded that a high voltage focus could result in higher neutron yield as compared with a lower voltage device of the same energy. The proper adjustments of the discharge parameters necessary due to the very short current risetime have been investigated. (orig.) [de

  6. Dynamics of 120 and 20 kV plasma focus devices with respect to density and current distribution, and neutron and X-ray emission

    International Nuclear Information System (INIS)

    Decker, G.; Nahrath, B.; Oppenlaender, T.; Pross, G.; Rueckle, B.; Schmidt, H.; Shakhatre, M.; Trunk, M.

    1977-01-01

    The experiments had two goals: (1) Better understanding of the dynamics and neutron production of the focus phase and (2) improved scaling of the neutron yield by operating a high-voltage focus. For the first goal, experiments with a 30-kJ/16-kV plasma focus of the Mather type (NESSI) were performed. The simultaneously applied diagnostics include interferometry, X-ray photography with channel plates, magnetic probes and scintillator/photomultiplier detectors for measuring hard X-ray and neutron emission. In the established chronology one can distinguish five phases in the development of the plasma focus: A compression phase is followed by a short (8 ns) very dense phase, where the density peaks at a minimum radius (t=0, authors' chronology). The plasma cylinder expands to a relatively long-lasting (30 to 70 ns) quiescent phase before instabilities occur. This short unstable phase is followed by a decay phase during which the neutron emission peaks. Important correlations between the plasma parameters and the neutron emission are discussed. Secondly, on the assumption that the neutron yield scales with a high power of the current, it was concluded that a high-voltage focus could result in higher neutron yield as compared with a lower voltage device of the same energy. The proper adjustments of the discharge parameters necessary due to the very short current risetime were investigated. (author)

  7. Theoretical Study of the Endogenous Production of N-13 in 115 kJ Plasma Focus Device Using Methane Gas

    Science.gov (United States)

    Faghih Haghani, Saeedeh; Sadighzadeh, A.; Talaei, A.; Zaeem, A. A.; Sadat Kiai, S. M.; Heydarnia, A.; Damideh, V.

    2013-08-01

    Mather type plasma focus device with the bank energy of 115 kJ (40 kV, 144μF) was studied for induced activity of N-13; a short-lived radioisotope β+ emitter with 511 keV of gamma rays and has a half-life of t1/2 = 9.93 min through 12C (d, n)13N nuclear reaction. N-13 radioisotope is used in Positron Emission Tomography (PET) for imaging and treatment. In this paper endogenous production of 13N is considered. It is shown by adding 3-4 % CH4 to the chamber, the induced activity of N-13 has increased about 4 %. Our study is representative of producing 106 - 109 Bq induced activity of this SLR in IR-MPF-100 device.

  8. Correlation of the neutron yield from the plasma focus upon variations in the magnetic field energy of the discharge circuit

    Science.gov (United States)

    Ablesimov, V. E.; Dolin, Yu. N.; Kalinychev, A. E.; Tsibikov, Z. S.

    2017-10-01

    The relation between neutron yield Y and magnetic field energy variations Δ W in the discharge circuit has been studied for a Mather-type plasma-focus camera. The activation technique (activation of silver isotopes) has been used to measure the integral yield of DD neutrons from the source. The time dependence of the neutron yield has been recorded by scintillation detectors. For the device used in the investigations, the neutron yield exhibits a linear dependence on variations in the magnetic field energy Δ W in the discharge circuit at the instant of neutron generation. It is also found that this dependence is related to the initial deuteron pressure in the discharge chamber.

  9. Density Transition Based Self-Focusing of cosh-Gaussian Laser Beam in Plasma with Linear Absorption

    International Nuclear Information System (INIS)

    Kant, Niti; Wani, Manzoor Ahmad

    2015-01-01

    Density transition based self-focusing of cosh-Gaussian laser beam in plasma with linear absorption has been studied. The field distribution in the plasma is expressed in terms of beam width parameter, decentered parameter, and linear absorption coefficient. The differential equation for the beam width parameter is solved by following Wentzel–Kramers–Brillouin (WKB) and paraxial approximation through parabolic wave equation approach. The behaviour of beam width parameter with dimensionless distance of propagation is studied at optimum values of plasma density, decentered parameter and with different absorption levels in the medium. The results reveal that these parameters can affect the self-focusing significantly. (paper)

  10. Pinching evidences in a miniature plasma focus with fast pseudospark switch

    International Nuclear Information System (INIS)

    Hassan, S M; Zhang, T; Patran, A; Rawat, R S; Springham, S V; Tan, T L; Wong, D; Wang, W; Lee, S; Gribkov, V A; Mohanty, S R; Lee, P

    2006-01-01

    We report the observations of pinching in a miniature plasma focus (PF) (58-160 J) operated in repetitive mode using fast pseudospark switch (PSS). The size of the device, which includes the capacitor bank, PSS and the focus chamber, is of the order of 22 cm x 22 cm x 38 cm. Several diagnostic tools, the gated imager, streak camera, current and voltage probe, are employed simultaneously to confirm the occurrence of pinching in this fast miniature PF device. The device is optimized for operation in neon and hydrogen as the working gas. The best focus formation was obtained at pressures between 0.5 to 8.0 mbar for neon and between 7.0 to 15.0 mbar for hydrogen. When the system was operated at 100 J with hydrogen as the filling gas, the typical dip in the current derivative signal and the typical peak in the voltage signal associated with pinch compression, are observed to be most intense indicating efficient pinching in the miniature PF device

  11. Space-time structure of neutron and X-ray sources in a plasma focus

    International Nuclear Information System (INIS)

    Bostick, W.H.; Nardi, V.; Prior, W.

    1977-01-01

    Systematic measurements with paraffin collimators of the neutron emission intensity have been completed on a plasma focus with a 15-20 kV capacitor bank (hollow centre electrode; discharge period T approximately 8 μs; D 2 filling at 4-8 torr). The space resolution was 1 cm or better. These data indicate that at least 70% of the total neutron yield originates within hot-plasma regions where electron beams and high-energy D beams (approximately > 0.1-1 MeV) are produced. The neutron source is composed of several (approximately > 1-10) space-localized sources of different intensity, each with a duration approximately less than 5 ns (FWHM). Localized neutron sources and hard (approximately > 100 keV) X-ray sources have the same time multiplicity and are usually distributed in two groups over a time interval 40-400 ns long. By the mode of operation used by the authors one group of localized sources (Burst II) is observed 200-400 ns after the other group (Burst I) and its space distribution is broader than for Burst I. The maximum intensity of a localized source of neutrons in Burst I is much higher than the maximum intensity in Burst II. Secondary reactions T(D,n) 4 He (from the tritium produced only by primary reactions in the same discharge; no tritium was used in filling the discharge chamber) are observed in a time coincidence with the strongest D-D neutron pulse of Burst I. The neutron signal from a localized source with high intensity has a relatively long tail of small amplitude (area tail approximately less than 0.2 X area peak). This tail can be generated by the D-D reactions of the unconfined part of an ion beam in the cold plasma. Complete elimination of scattered neutrons on the detector was achieved in these measurements. (author)

  12. Design, fabrication, and characterization of a 2.3 kJ plasma focus of negative inner electrode

    International Nuclear Information System (INIS)

    Mathuthu, M.; Zengeni, T.G.; Gholap, A.V.

    1997-01-01

    The design, fabrication, and characterization of a 2.3 kJ plasma focus device with negative inner electrode are discussed. The purpose of the design was to initiate research in and study of plasma dynamics, nuclear reactions, and neutron emission mechanisms at the university. Also the device will be used to teach and demonstrate plasma phenomena at the postgraduate level and to perform experiments with inverted polarity to examine different operating regimes with nonstandard gases. It is hoped that in the long run the research work will help find a solution to the polarity riddle of plasma focus devices. When the system was operated with spectrographic argon as the filling gas, the best focus was obtained at a pressure range of 0.1 endash 1.25 Torr. With nitrogen as the filling gas, the best focus was obtained at pressures between 0.1 and 1.25 Torr. Air gave the best focus at a pressure range of 0.5 endash 1.5 Torr. The observed good focus action is attributed to the small inner electrode length (this reduces the amount of anode material ablated into the current sheath) and tapering of the inner electrode. Positive z-directed electrons contribute to the temperature and further ionization of the plasma gas during focusing. The performance of the device compares quite well with other known devices. copyright 1997 American Institute of Physics

  13. Characteristics of x-rays from a plasma focus operated with neon gas

    Energy Technology Data Exchange (ETDEWEB)

    Zakaullah, M [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Alamgir, K [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Shafiq, M [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Hassan, S M [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Sharif, M [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Hussain, S [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Waheed, A [PINSTECH, PO Box 2151, 44000 Islamabad (Pakistan)

    2002-11-01

    The x-ray emission from a low-energy (2.3 kJ) plasma focus is investigated with neon as the filling gas. Two anode configurations are used in the experiment: the conventional cylindrical anode, and tapered anode slightly toward the open end. The latter geometry enhances soft x-ray emission by an order of magnitude. The emission is pressure dependent and, in both cases, the highest emission is observed at 3-3.5 mbar. For the cylindrical anode, the soft x-ray emission is up to 7 J per shot, which is from a pinched plasma column, 5-6 mm long. For the tapered anode, up to 80 J per shot soft x-ray yield in 4{pi} geometry is recorded, which corresponds to 4% wall plug efficiency. The diameter of the x-ray emission filament is much larger compared with the cylindrical anode. The bulk of emitted radiation is of energy 1.2-1.3 keV, which is thought to arise from recombination of hydrogen-like (Ne x) ions with the low-energy electrons.

  14. Characteristics of x-rays from a plasma focus operated with neon gas

    International Nuclear Information System (INIS)

    Zakaullah, M; Alamgir, K; Shafiq, M; Hassan, S M; Sharif, M; Hussain, S; Waheed, A

    2002-01-01

    The x-ray emission from a low-energy (2.3 kJ) plasma focus is investigated with neon as the filling gas. Two anode configurations are used in the experiment: the conventional cylindrical anode, and tapered anode slightly toward the open end. The latter geometry enhances soft x-ray emission by an order of magnitude. The emission is pressure dependent and, in both cases, the highest emission is observed at 3-3.5 mbar. For the cylindrical anode, the soft x-ray emission is up to 7 J per shot, which is from a pinched plasma column, 5-6 mm long. For the tapered anode, up to 80 J per shot soft x-ray yield in 4π geometry is recorded, which corresponds to 4% wall plug efficiency. The diameter of the x-ray emission filament is much larger compared with the cylindrical anode. The bulk of emitted radiation is of energy 1.2-1.3 keV, which is thought to arise from recombination of hydrogen-like (Ne x) ions with the low-energy electrons

  15. Varying Radii of On-Axis Anode Hollows For kJ-Class Dense Plasma Focus

    Science.gov (United States)

    Shaw, Brian; Chapman, Steven; Falabella, Steven; Pankin, Alexei; Liu, Jason; Link, Anthony; Schmidt, Andréa

    2017-10-01

    A dense plasma focus (DPF) is a compact plasma gun that produces high energy ion beams, up to several MeV, through strong potential gradients. Motivated by particle-in-cell simulations, we have tried a series of hollow anodes on our kJ-class DPF. Each anode has varying hollow sizes, and has been studied to optimize ion beam production in Helium, reduce anode sputter, and increase neutron yields in deuterium. We diagnose the rate at which electrode material is ablated and deposited onto nearby surfaces. This is of interest in the case of solid targets, which perform poorly in the presence of sputter. We have found that the larger the hollow radius produces more energetic ion beams, higher neutron yield, and sputter less than a flat top anode. A complete comparison is presented. This work was prepared by LLNL under Contract DE-AC52-07NA27344 and supported by Office of Defense Nuclear Nonproliferation Research and Development within U.S. Department of Energy's National Nuclear Security Administration.

  16. Development of X-ray and ion diagnostic methods for plasma focus research

    International Nuclear Information System (INIS)

    Sadowski, M.

    1986-12-01

    A review of experimental methods used for investigation of X-rays and ion-beams emmited from plasma focus facilities is presented. The research program has been realized at the Institute for Nuclear Studies in Swierk and at the Institut fuer Plasmaforschung in Stuttgart, within the frames of an international co-operation. The studies on ion emission from different PF facilities are reviewed. The application of CN-films with Al-filters and of different ion-pinhole cameras is described. The use of a Thomson mass-spectrometer adopted for plasma studies is presented. The time-resolved measurements combined with a simultaneous mass- and energy-analysis of the ion beams are also described. The most important results of these studies are summarized. Particular attention is also paid to the studies of the X-ray emission. The use of stereoscopic sets of vacuum pinhole cameras with thin Be-filters is described. The application of X-ray pinhole cameras equipped with miniature scintillators for time-resolved measurements is also presented. The most important results of the X-ray emission studies are summarized. 35 refs., 12 figs. (author)

  17. Two-dimensional magnetohydrodynamic calculations for a 5 MJ plasma focus

    International Nuclear Information System (INIS)

    Maxon, S.

    1979-01-01

    The performance of a 5 MJ plasma focus is calculated using our two-dimensional magnetohydrodynamic (2-D MHD) code. Two configurations are discussed, a solid and a hollow anode. In the case of the hollow anode, we find an instability in the current sheath which has the characteristics of the short wave length sausage instability. As the current sheath reaches the axis, the numerical solution is seen to break down. Just before this time, plasma parameters take on the characteristic values rho/rho 0 = 143, kT/sup i/ = 7.4 keV, B/sub theta/ = 4.7 MG, and V/sub z/ = 60 cm/μs for a zone with r = 0.2 mm. When the numerical solution breaks down, the code shows a splitting of the current sheath (from the axis to the anode) and the loss of a large amount of magnetic energy. Current-sheath stagnation is observed in the hollow anode configuration, also

  18. Hot spots and filaments in the pinch of a plasma focus: a unified approach

    International Nuclear Information System (INIS)

    Di Vita, A.

    2009-01-01

    To date, no MHD-based complete description of the tiny, relatively stable, well-ordered structures (hot spots, filaments) observed in the pinch of a plasma focus seems to be feasible. Indeed, the large value of electron density suggests that a classification of such structures which is based on the approximation of local thermodynamical equilibrium (LTE) is possible. Starting from an often overlooked, far-reaching result of LTE, we derive a purely analytical description of both hot spots and filaments. In spite of their quite different topology, both configurations are extrema of the same variational principle. Well-known results of conventional MHD are retrieved as benchmark cases. It turns out that hot spots satisfy Taylor's principle of constrained minimum of magnetic energy, the constraint being given by fixed magnetic helicity. Filaments are similar to the filaments of a superconductor and form a plasma with β equals 0.11 and energy diffusion coefficient equals 0.88*D(Bohm). Any process - like e.g. radiative collapse - which raises particle density while reducing radial size may transform filaments into hot spots. A well-known scaling law is retrieved - the collisional Vlasov high beta scaling. A link between dissipation and topology is highlighted. Accordingly, a large-current pinch may give birth to tiny hot spots with large electron density and magnetic field. (author)

  19. Time resolved energy spectrum of the axial ion beam generated in plasma focus discharges

    International Nuclear Information System (INIS)

    Bostick, W.H.; Kilic, H.; Nardi, V.; Powell, C.W.

    1993-01-01

    The energy spectrum of the deuteron beam along the electrode axis (0 (degree) ) in a plasma focus discharge has been determined with a time of flight (TOF) method and with a differential filter method in the ion energy interval E = 0.3-9 MeV. The ion TOF method is applied to single-ion pulse events with an ion emission time t(E) that is only weakly dependent on the ion energy E for E > 0.3 MeV. The correlation of the ion beam intensity with the filling pressure, the neutron yield and the hard X-ray intensity is also reported. (author). 11 refs, 10 figs

  20. Electromagnetic particle in cell modeling of the plasma focus: Current sheath formation and lift off

    International Nuclear Information System (INIS)

    Seng, Y. S.; Lee, P.; Rawat, R. S.

    2014-01-01

    The shaping and formation of the current sheath takes place in the breakdown phase of a plasma focus device and critically controls the device performance. Electrostatic particle in cell codes, with magnetic effects ignored, have been used to model the breakdown phase. This Letter reports the successful development and implementation of an electromagnetic particle in cell (EMPIC) code, including magnetic effects self-consistently, to simulate the breakdown phase; from the ionization, localization and gliding discharge along the insulator to the time instant of current sheath lift off. The magnetic field was found to be appreciable from the time the current sheath came into contact with the anode with increased local current, initiating the voltage breakdown of the device as a result

  1. Discrete focusing effect of positive ions by a plasma-sheath lens

    International Nuclear Information System (INIS)

    Stamate, E.; Sugai, H.

    2005-01-01

    We demonstrate that the sheath created adjacent to the surface of a negatively biased electrode that interfaces an insulator acts as a lens that focuses the positive ions to distinct regions on the surface. Thus, the positive ion flux is discrete, leading to the formation of a passive surface, of no ion impact, near the edge and an active surface at the center. Trajectories of positive ions within the sheath are obtained by solving in three dimensions the Poisson equation for electrodes of different geometry. Simulations are confirmed by developing the ion flux profile on the electrode surface as the sputtering pattern produced by ion impact. Measurements are performed in a dc plasma produced in Ar gas

  2. Experimental studies of fast deuterons, impurity- and admixture-ions emitted from a plasma focus

    International Nuclear Information System (INIS)

    Mozer, A.; Sadowski, M.; Herold, H.; Schmidt, H.

    1982-01-01

    The energy and mass analysis of ions emitted from a 50-kJ, 18-kV, plasma focus machine was performed with a Thomson analyzer. Energy distribution functions of fast deuterons (E> or =350 keV) and those of impurity ions have been determined. The energy distributions of the O, N, and C impurity ions in different ionization states have similar character. They usually increase exponentially and after reaching the maximum at E/Zroughly-equal1.0 MeV they decrease exponentially to E/Zroughly-equal1.8 MeV. For deuterons at lower operating pressures (p 0 + -Ar 7+ ions of energy from 0.5 to 14 MeV are produced

  3. A study of x-ray emission from the anode region in a plasma focus device

    International Nuclear Information System (INIS)

    Jia Wang; Tsinchi Yang

    1988-01-01

    The physical process of x-ray emission from the anode region in a plasma focus device due to the interaction of a powerful electron beam with the metal anode and with ionised metallic vapour from the anode is investigated. The influence of the magnetic field of the beam is taken into consideration. A MC-PIC model (Monte Carlo-particle in cell) is proposed for the process, in which an electron-photon collision cascade is simulated by the MC approach and the time-dependent state of metallic vapour is determined by PIC computation. The time-resolved energy spectra and angular distributions of x-ray emission from the extending anode region are calculated. The time-integrated characteristics of the x-ray emission can be compared with the results of experiments as far as they are available. (author)

  4. Efficacy of liver assisting in patients with hepatic encephalopathy with special focus on plasma exchange

    DEFF Research Database (Denmark)

    Stenbøg, Poul; Busk, Troels; Larsen, Fin Stolze

    2013-01-01

    Severe liver injury result in development of hepatic encephalopathy (HE) and often also in brain edema that is a potentially fatal complication. HE and brain edema are correlated to the level and persistence of hyperammonemia and the presence of systemic inflammation. Treatment of HE and brain...... edema is based on restoring and keeping normal physiological variables including tonicity, blood gasses, lactate, temperature and vascular resistance by a wide variety of interventions. In addition liver support devices improve the stage of HE, cerebral metabolic rate for oxygen and glucose......, and are used either as a bridge to liver transplantation or liver recovery in patients with fulminant hepatic failure and in patients with acute-on-chronic liver failure. This short review will mainly focus on the management and efficacy of doing plasma exchange on HE in patients with acute HE....

  5. Working gas effects on the X-ray emission of a plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Cengher, M; Presura, R; Zoita, V [Inst. of Physics and Technology of Radiation Devices, Bucharest (Romania)

    1997-12-31

    Experiments on the plasma focus device IPF-2/20 operating with argon, neon and mixtures of argon with deuterium were performed and some X-ray emission parameters measured. The time evolution of the X-ray emission and dependence of the X-ray yield on the working gas composition was analyzed. The softer X radiation was measured with time resolution in the energy bands from 4 to 40 keV, and the hard X-rays for energies above 200 keV. In deuterium-argon mixtures the soft X-ray yield increases both with pressure (for the same ratio of argon) and with the quantity of argon added to deuterium at the same total pressure. For argon or neon the hard X-ray yield is lower than for deuterium-heavy gas mixtures. The softer X-ray yield decreases with pressure both for neon and for argon. (author). 4 figs., 5 refs.

  6. Review of results from the FN-2 dense plasma focus machine

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, J.J.E.; Castillo, F.; Gamboa, I.; Rangel, J. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico); Golzarri, J.I.; Espinosa, G. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2004-07-01

    The FN-II is a small dense plasma focus (4.8 kJ at 36 kV), operating at the University of Mexico. Substantial effort has been dedicated to the study of the anisotropy in the neutron, proton and hard X-ray radiation. Concerning the neutron, it has been observed that there is an anisotropic distribution superposed on a far larger isotropic one. These clearly separated effects can be interpreted as the consequence of two different neutron emission mechanisms. The shape of the proton distribution is very similar to the neutron one. The angular distribution of hard X-rays and ions is also studied within the chamber with TLD and CR-39 detectors respectively. Two maxima are found around the axis of the device for X rays within the 20-200 keV range. (authors)

  7. Measurements of fast electron beams and soft X-ray emission from plasma-focus experiments

    Directory of Open Access Journals (Sweden)

    Surała Władysław

    2016-06-01

    Full Text Available The paper reports results of the recent experimental studies of pulsed electron beams and soft X-rays in plasma-focus (PF experiments carried out within a modified PF-360U facility at the NCBJ, Poland. Particular attention was focused on time-resolved measurements of the fast electron beams by means of two different magnetic analyzers, which could record electrons of energy ranging from about 41 keV to about 715 keV in several (6 or 8 measuring channels. For discharges performed with the pure deuterium filling, many strong electron signals were recorded in all the measuring channels. Those signals were well correlated with the first hard X-ray pulse detected by an external scintillation neutron-counter. In some of the analyzer channels, electron spikes (lasting about dozens of nanoseconds and appearing in different instants after the current peculiarity (so-called current dip were also recorded. For several discharges, fast ion beams, which were emitted along the z-axis and recorded with nuclear track detectors, were also investigated. Those measurements confirmed a multibeam character of the ion emission. The time-integrated soft X-ray images, which were taken side-on by means of a pinhole camera and sensitive X-ray films, showed the appearance of some filamentary structures and so-called hot spots. The application of small amounts of admixtures of different heavy noble gases, i.e. of argon (4.8% volumetric, krypton (1.6% volumetric, or xenon (0.8% volumetric, decreased intensity of the recorded electron beams, but increased intensity of the soft X-ray emission and showed more distinct and numerous hot spots. The recorded electron spikes have been explained as signals produced by quasi-mono-energetic microbeams emitted from tiny sources (probably plasma diodes, which can be formed near the observed hot spots.

  8. Effect of Wall Material on H– Production in a Plasma Sputter-Type Ion Source

    Directory of Open Access Journals (Sweden)

    Y. D. M. Ponce

    2004-12-01

    Full Text Available The effect of wall material on negative hydrogen ion (H– production was investigated in a multicusp plasma sputter-type ion source (PSTIS. Steady-state cesium-seeded hydrogen plasma was generated by a tungsten filament, while H– was produced through surface production using a molybdenum sputter target. Plasma parameters and H– yields were determined from Langmuir probe and Faraday cup measurements, respectively. At an input hydrogen pressure of 1.2 mTorr and optimum plasma discharge parameters Vd = –90 V and Id = –2.25 A, the plasma parameters ne was highest and T–e was lowest as determined from Langmuir probe measurements. At these conditions, aluminum generates the highest ion current density of 0.01697 mA/cm2, which is 64% more than the 0.01085 mA/cm2 that stainless steel produces. The yield of copper, meanwhile, falls between the two materials at 0.01164 mA/cm2. The beam is maximum at Vt = –125 V. Focusing is achieved at VL = –70 V for stainless steel, Vt = –60 V for aluminum, and Vt = –50 V for copper. The results demonstrate that proper selection of wall material can greatly enhance the H– production of the PSTIS.

  9. Generation of second-harmonic radiations of a self-focusing laser from a plasma with density-transition

    International Nuclear Information System (INIS)

    Kant, Niti; Gupta, Devki Nandan; Suk, Hyyong

    2011-01-01

    A Gaussian laser-beam resonantly generates a second-harmonic wave in a plasma in the presence of a wiggler magnetic-field of suitable period. The self-focusing of the fundamental pulse enhances the intensity of the second-harmonic pulse. An introduction of an upward plasma-density ramp strongly enhances the self-focusing of the fundamental laser pulse. The laser pulse attains a minimum spot size and propagates up to several Rayleigh lengths without divergence. Due to the strong self-focusing of the fundamental laser pulse, the second-harmonic intensity enhances significantly. A considerable enhancement of the intensity of the second-harmonic is observed from the proposed mechanism. -- Highlights: → An upward plasma-density ramp is very important for laser propagation in plasmas. → As the plasma density increases, effect of self-focusing becomes stronger. → We utilize this self-focused laser to generate second-harmonic radiations. → The self-focusing laser enhances the intensity of the second-harmonic pulse.

  10. Generation of second-harmonic radiations of a self-focusing laser from a plasma with density-transition

    Energy Technology Data Exchange (ETDEWEB)

    Kant, Niti [Department of Physics, Lovely Professional University, Phagwara 144 402, Punjab (India); Gupta, Devki Nandan, E-mail: dngupta@physics.du.ac.in [Department of Physics and Astrophysics, University of Delhi, Delhi 110 007 (India); Suk, Hyyong [Advanced Photonics Research Institute (APRI) and Graduate Program of Photonics and Applied Physics, Gwangju Institute of Science and Technology, Gwangju 500 712 (Korea, Republic of)

    2011-08-15

    A Gaussian laser-beam resonantly generates a second-harmonic wave in a plasma in the presence of a wiggler magnetic-field of suitable period. The self-focusing of the fundamental pulse enhances the intensity of the second-harmonic pulse. An introduction of an upward plasma-density ramp strongly enhances the self-focusing of the fundamental laser pulse. The laser pulse attains a minimum spot size and propagates up to several Rayleigh lengths without divergence. Due to the strong self-focusing of the fundamental laser pulse, the second-harmonic intensity enhances significantly. A considerable enhancement of the intensity of the second-harmonic is observed from the proposed mechanism. -- Highlights: → An upward plasma-density ramp is very important for laser propagation in plasmas. → As the plasma density increases, effect of self-focusing becomes stronger. → We utilize this self-focused laser to generate second-harmonic radiations. → The self-focusing laser enhances the intensity of the second-harmonic pulse.

  11. Numerical experiments on plasma focus for soft x-ray yield scaling laws derivation using Lee model

    International Nuclear Information System (INIS)

    Akel, M.

    2015-01-01

    The required plasma parameters of krypton and xenon at different temperatures were calculated, the x-ray emission properties of plasmas were studied, and based on the corona model the suitable temperature range for generating H-like and He-like ions (therefore soft x-ray emissions) of different gases plasma were found. The code is applied to characterize the plasma focus in different plasma focus devices, and for optimizing the nitrogen, oxygen, neon, argon, krypton and xenon soft x-ray yields based on bank, tubes and operating parameters. It is found that t he soft x-ray yield increases with changing pressure until it reaches the maximum value for each plasma focus device. Keeping the bank parameters, operational voltage unchanged but systematically changing other parameters, numerical experiments were performed finding the optimum combination of Po, z0 and 'a' for the maximum soft x-ray yield. Thus we expect to increase the soft x-ray yield of plasma focus device several-fold from its present typical operation; without changing the capacitor bank, merely by changing the electrode configuration and the operating pressure. The Lee model code was also used to run numerical experiments on plasma focus devices for optimizing soft x-ray yield with reducing Lo, varying z0 and 'a' to get engineering designs with maximum soft x-ray yield for these devices at different experimental conditions and gases. Numerical experiments showed the influence of the gas used in plasma focus and its propor ties on soft x-ray emission and its propor ties and then on its applications. Scaling laws for soft x-ray of nitrogen, oxygen, neon, argon, krypton and xenon plasma focus in terms of energy, peak discharge current and focus pinch current were found. Radiative cooling effects are studied indicating that radiative collapse may be observed for heavy noble gases (Ar, Kr, Xe) for pinch currents even below 100 k A. The results show that the line radiation emission and

  12. Numerical experiments on plasma focus for soft x-ray yield scaling laws derivation using Lee model

    International Nuclear Information System (INIS)

    Akel, M.

    2012-09-01

    The required plasma parameters of krypton and xenon at different temperatures were calculated, the x-ray emission properties of plasmas were studied, and based on the corona model the suitable temperature range for generating H-like and He-like ions (therefore soft x-ray emissions) of different gases plasma were found. The code is applied to characterize the plasma focus in different plasma focus devices, and for optimizing the nitrogen, oxygen, neon, argon, krypton and xenon soft x-ray yields based on bank, tubes and operating parameters. It is found that the soft x-ray yield increases with changing pressure until it reaches the maximum value for each plasma focus device. Keeping the bank parameters, operational voltage unchanged but systematically changing other parameters, numerical experiments were performed finding the optimum combination of P o , Z o and 'a' for the maximum soft x-ray yield. Thus we expect to increase the soft x-ray yield of plasma focus device several-fold from its present typical operation; without changing the capacitor bank, merely by changing the electrode configuration and the operating pressure. The Lee model code was also used to run numerical experiments on plasma focus devices for optimizing soft x-ray yield with reducing L o , varying L o and 'a' to get engineering designs with maximum soft x-ray yield for these devices at different experimental conditions and gases. Numerical experiments showed the influence of the gas used in plasma focus and its properties on soft x-ray emission and its properties and then on its applications. Scaling laws for soft x-ray of nitrogen, oxygen, neon, argon, krypton and xenon plasma focus, in terms of energy, peak discharge current and focus pinch current were found. Radiative cooling effects are studied indicating that radiative collapse may be observed for heavy noble gases (Ar, Kr, Xe) for pinch currents even below 100 kA. The results show that the line radiation emission and tube voltages have

  13. Utilizing the ratio and the summation of two spectral lines for estimation of optical depth: Focus on thick plasmas

    Science.gov (United States)

    Rezaei, Fatemeh; Tavassoli, Seyed Hassan

    2016-11-01

    In this paper, a study is performed on the spectral lines of plasma radiations created from focusing of the Nd:YAG laser on Al standard alloys at atmospheric air pressure. A new theoretical method is presented to investigate the evolution of the optical depth of the plasma based on the radiative transfer equation, in LTE condition. This work relies on the Boltzmann distribution, lines broadening equations, and as well as the self-absorption relation. Then, an experimental set-up is devised to extract some of plasma parameters such as temperature from modified line ratio analysis, electron density from Stark broadening mechanism, line intensities of two spectral lines in the same order of ionization from similar species, and the plasma length from the shadowgraphy section. In this method, the summation and the ratio of two spectral lines are considered for evaluation of the temporal variations of the plasma parameters in a LIBS homogeneous plasma. The main advantage of this method is that it comprises the both of thin and thick laser induced plasmas without straight calculation of self-absorption coefficient. Moreover, the presented model can also be utilized for evaluation the transition of plasma from the thin condition to the thick one. The results illustrated that by measuring the line intensities of two spectral lines at different evolution times, the plasma cooling and the growth of the optical depth can be followed.

  14. Effect of exponential density transition on self-focusing of q-Gaussian laser beam in collisionless plasma

    Science.gov (United States)

    Valkunde, Amol T.; Vhanmore, Bandopant D.; Urunkar, Trupti U.; Gavade, Kusum M.; Patil, Sandip D.; Takale, Mansing V.

    2018-05-01

    In this work, nonlinear aspects of a high intensity q-Gaussian laser beam propagating in collisionless plasma having upward density ramp of exponential profiles is studied. We have employed the nonlinearity in dielectric function of plasma by considering ponderomotive nonlinearity. The differential equation governing the dimensionless beam width parameter is achieved by using Wentzel-Kramers-Brillouin (WKB) and paraxial approximations and solved it numerically by using Runge-Kutta fourth order method. Effect of exponential density ramp profile on self-focusing of q-Gaussian laser beam for various values of q is systematically carried out and compared with results Gaussian laser beam propagating in collisionless plasma having uniform density. It is found that exponential plasma density ramp causes the laser beam to become more focused and gives reasonably interesting results.

  15. Deposition of Al N and Ti N thin films on substrates of stainless steel SS304 using plasma focus device

    International Nuclear Information System (INIS)

    Al-Hawat, Sh.; Soukieh, M.; Abou Kharoub, M.; Al-Sadat, W.

    2006-06-01

    A 2.8 kJ plasma focus device was used to deposit thin films of aluminium nitride Al N and titanium nitride Ti N on a stainless steel 394 substrate, in order to improve its surface properties. The deposition process was carried out using various number of nitrogen plasma shots at pressures 0.5-0.75 mbar and at different sample's distances from the anode. The plasma diagnostics was achieved using the voltage and current signals recorded by a voltage divider and Rogovskii coil to determine the temperature and plasma density. The surface hardness of SS-304 was increased by about 50% after plasma coating and the thickness of the coated layers was about 1-2μm. This study shows that the hardness is increased with increasing the number of shots and decreased with the distance from the anode. The coated layers were characterized and a qualitative understanding of the deposition process was given. (author)

  16. The Optimal Conditions for Form-Focused Instruction: Method, Target Complexity, and Types of Knowledge

    Science.gov (United States)

    Kim, Jeong-eun

    2012-01-01

    This dissertation investigates optimal conditions for form-focused instruction (FFI) by considering effects of internal (i.e., timing and types of FFI) and external (i.e., complexity and familiarity) variables of FFI when it is offered within a primarily meaning-focused context of adult second language (L2) learning. Ninety-two Korean-speaking…

  17. Correlating neutron yield and reliability for selecting experimental parameters for a plasma focus machine

    International Nuclear Information System (INIS)

    Pross, G.

    Possibilities of optimizing focus machines with a given energy content in the sense of high neutron yield and high reliability of the discharges are investigated experimentally. For this purpose, a focus machine of the Mather type with an energy content of 12 kJ was constructed. The following experimental parameters were varied: the material of the insulator in the ignition zone, the structure of the outside electrode, the length of the inside electrode, the filling pressure and the amount and polarity of the battery voltage. An important part of the diagnostic program consists of measurements of the azimuthal and axial current distribution in the accelerator, correlated with short-term photographs of the luminous front as a function of time. The results are given. A functional schematic has been drafted for focus discharge as an aid in extensive optimization of focus machines, combining findings from theory and experiments. The schematic takes into account the multiparameter character of the discharge and clarifies relationships between the experimental parameters and the target variables neutron yield and reliability

  18. Effects of fusion relevant transient energetic radiation, plasma and thermal load on PLANSEE double forged tungsten samples in a low-energy plasma focus device

    Science.gov (United States)

    Javadi, S.; Ouyang, B.; Zhang, Z.; Ghoranneviss, M.; Salar Elahi, A.; Rawat, R. S.

    2018-06-01

    Tungsten is the leading candidate for plasma facing component (PFC) material for thermonuclear fusion reactors and various efforts are ongoing to evaluate its performance or response to intense fusion relevant radiation, plasma and thermal loads. This paper investigates the effects of hot dense decaying pinch plasma, highly energetic deuterium ions and fusion neutrons generated in a low-energy (3.0 kJ) plasma focus device on the structure, morphology and hardness of the PLANSEE double forged tungsten (W) samples surfaces. The tungsten samples were provided by Forschungszentrum Juelich (FZJ), Germany via International Atomic Energy Agency, Vienna, Austria. Tungsten samples were irradiated using different number of plasma focus (PF) shots (1, 5 and 10) at a fixed axial distance of 5 cm from the anode top and also at various distances from the top of the anode (5, 7, 9 and 11 cm) using fixed number (5) of plasma focus shots. The virgin tungsten sample had bcc structure (α-W phase). After PF irradiation, the XRD analysis showed (i) the presence of low intensity new diffraction peak corresponding to β-W phase at (211) crystalline plane indicating the partial structural phase transition in some of the samples, (ii) partial amorphization, and (iii) vacancy defects formation and compressive stress in irradiated tungsten samples. Field emission scanning electron microscopy showed the distinctive changes to non-uniform surface with nanometer sized particles and particle agglomerates along with large surface cracks at higher number of irradiation shots. X-ray photoelectron spectroscopy analysis demonstrated the reduction in relative tungsten oxide content and the increase in metallic tungsten after irradiation. Hardness of irradiated samples initially increased for one shot exposure due to reduction in tungsten oxide phase, but then decreased with increasing number of shots due to increasing concentration of defects. It is demonstrated that the plasma focus device provides

  19. Study of the thermal and suprathermal electron density fluctuations of the plasma in the Focus experiment

    International Nuclear Information System (INIS)

    Jolas, A.

    1981-10-01

    An experiment on Thomson scattering of ruby laser light by the electrons of a plasma produced by an intense discharge between the electrodes of a coaxial gun in a gas at low pressure has been carried out. It is shown that the imploding plasma is made up of layers with different characteristics: a dense plasma layer where the density fluctuations are isotropic and have a thermal level, and a tenuous plasma layer where the fluctuations are anisotropic, and strongly suprathermal. The suprathermal fluctuations are attributed to microscopic instabilities generated by the electric current circulating in the transition zone where the magnetic field penetrates the plasma [fr

  20. Preliminary design of a 150 kJ repetitive plasma focus for the production of 18-F

    Science.gov (United States)

    Sumini, Marco; Mostacci, Domiziano; Rocchi, Federico; Frignani, Michele; Tartari, Agostino; Angeli, Ergisto; Galaverni, Dario; Coli, Ugo; Ascione, Bernardino; Cucchi, Giorgio

    2006-06-01

    Experiments in the past five years have demonstrated production of short-lived radioisotopes with a Plasma Focus device, using the so-termed Endogenous Mode. So far radioisotope activities of only a few microcuries have been obtained from single discharges in small scale Plasma Focus machines (capacitor bank energies of approximately 7 kJ). It is expected that higher activities could be obtained with larger bank energies, operating at high pulse repetition rates, e.g. 1 Hz. However, many scientific and technological issues must be addressed for a high-energy Plasma Focus device to run at one pulse per second. Aim of this paper is to present preliminary results pertaining to the plasma, electrical, fluid-dynamical, thermal, material and mechanical design of a 150 kJ Plasma Focus, capable of a repetition rate of 1 Hz, that will be operated at 30 kV with a 350 μF capacitor bank and a maximum total current of 1.5 MA. This device will be used to breed 18-F for the synthesis of drugs used in positron-emission medical examinations, such as FDG for PET.

  1. Preliminary design of a 150 kJ repetitive plasma focus for the production of 18-F

    International Nuclear Information System (INIS)

    Sumini, Marco; Mostacci, Domiziano; Rocchi, Federico; Frignani, Michele; Tartari, Agostino; Angeli, Ergisto; Galaverni, Dario; Coli, Ugo; Ascione, Bernardino; Cucchi, Giorgio

    2006-01-01

    Experiments in the past five years have demonstrated production of short-lived radioisotopes with a Plasma Focus device, using the so-termed Endogenous Mode. So far radioisotope activities of only a few microcuries have been obtained from single discharges in small scale Plasma Focus machines (capacitor bank energies of approximately 7 kJ). It is expected that higher activities could be obtained with larger bank energies, operating at high pulse repetition rates, e.g. 1 Hz. However, many scientific and technological issues must be addressed for a high-energy Plasma Focus device to run at one pulse per second. Aim of this paper is to present preliminary results pertaining to the plasma, electrical, fluid-dynamical, thermal, material and mechanical design of a 150 kJ Plasma Focus, capable of a repetition rate of 1 Hz, that will be operated at 30 kV with a 350 μF capacitor bank and a maximum total current of 1.5 MA. This device will be used to breed 18-F for the synthesis of drugs used in positron-emission medical examinations, such as FDG for PET

  2. Research on pinches driven by Speed-2 generator: Hard X-ray and neutron emission in plasma focus configuration

    Energy Technology Data Exchange (ETDEWEB)

    Soto, L.; Moreno, J.; Silva, P.; Sylvester, G.; Zambra, M.; Pavez, C. [Comision Chilena de Energia Nuclear, Santiago (Chile); Pavez, C. [Universidad de Concepcion (Chile); Raspa, V. [Buenos Aires Univ., PLADEMA, CONICET and INFIP (Argentina); Castillo, F. [Insitituto de Ciencias Nucleares, UNAM (Mexico); Kies, W. [Heinrich-Heine-Univ., Dusseldorf (Germany)

    2004-07-01

    Speed-2 is a generator based on Marx technology and was designed in the University of Dusseldorf. Speed-2 consists on 40 +/- Marx modules connected in parallel (4.1 {mu}F equivalent Marx generator capacity, 300 kV, 4 MA in short circuit, 187 kJ, 400 ns rise time, dI/dt {approx} 10{sup 13} A/s). Currently Speed-2 is operating at CCHEN (Chilean nuclear energy commission), being the most powerful and energetic device for dense transient plasma in the Southern Hemisphere. Most of the previous works developed in Speed-2 at Dusseldorf were done in a plasma focus configuration for soft X-ray emission and the neutron emission from Speed-2 was not completely studied. The research program at CCHEN considers experiments in different pinch configurations (plasma focus, gas puffed plasma focus, gas embedded Z-pinch, wire arrays) at current of hundred of kilo- to mega-amperes, using the Speed-2 generator. The Chilean operation has begun implementing and developing diagnostics in a conventional plasma focus configuration operating in deuterium in order to characterize the neutron emission and the hard X-ray production. Silver activation counters, plastics CR39 and scintillator-photomultiplier detectors are used to characterize the neutron emission. Images of metallic plates with different thickness are obtained on commercial radiographic film, Agfa Curix ST-G2, in order to characterize an effective energy of the hard X-ray outside of the discharge. (authors)

  3. Plasma focus as an x-ray source for tailoring of radiation in different energy windows

    International Nuclear Information System (INIS)

    Zakaullah, M.; Alamgir, K.; Shafiq, M.; Sharif, M.

    2001-01-01

    A low energy (2.3 kj) plasma focus energized by a single 32 micro f capacitor charged at 12 kv with filling gases hydrogen, neon and argon is investigated as an X-ray source. Experiments are conducted with a copper and an aluminum anode. Specifically, attention in given to tailoring the radiation in different windows, e. g. 1.2-1.3 keV, 1.3-1.5 keV, 2.5-5 keV and Cu-Ka line radiation. The highest X-ray emission is observed with neon filling and the copper anode in the 1.2-1.3 keV window, which speculated to be generated due to recombination of hydrogen like neon ions with a few eV to a few 10s of eV electrons. The wall-plug efficiency of the device is found to be 4%. The other significant emission occurs with Hydrogen filling, which exhibits wall plug efficiency of 1.7% for over all x-ray emission and 0.35% for Cu- Ka line radiation. The emission is dominated by the interaction of electrons in the current sheath with the anode tip. The emission with the aluminum anode and hydrogen filling is up to 10 j, which corresponds to wall-plug efficiency of 0.4%. The X-ray emission with argon filling is less significant. (author)

  4. Properties of hotspots in plasma focus discharges operating in hydrogen-argon mixtures

    International Nuclear Information System (INIS)

    Silva, P; Favre, M

    2002-01-01

    We have investigated the properties of hotspots formed in low energy plasma focus (PF) discharges operating in hydrogen-argon mixtures, at 140 kA current level. A combination of filtered pinhole and slit-wire camera is used to measure the hotspot size and temperature. The results show that the best conditions for reproducible and localized hotspot formation are obtained by adjusting the base pressure in such a way that the mass load allows the time of first radial collapse to coincide with peak current. When the PF is operated with 20% argon content, rather uniform hotspots, of 115 μm characteristic size and 300 eV characteristic temperature, are produced with a better than 80% reproducibility in their axial localization. The electron density in the hotspots is estimated to be ∼10 20 cm -3 . Calculations performed with a CRE code indicate that a significant fraction of the radiation is emitted in the 3.2 to 3.88 keV region, corresponding to K α emission from highly ionized argon

  5. In situ determination of the static inductance and resistance of a plasma focus capacitor bank

    Energy Technology Data Exchange (ETDEWEB)

    Saw, S. H. [INTI University College, Nilai 71800 (Malaysia); Institute for Plasma Focus Studies, 32 Oakpark Drive, Chadstone, Victoria 3148 (Australia); Lee, S. [INTI University College, Nilai 71800 (Malaysia); Institute for Plasma Focus Studies, 32 Oakpark Drive, Chadstone, Victoria 3148 (Australia); National Institute of Education, Nanyang Technological University, Singapore 637616 (Singapore); Roy, F.; Chong, P. L.; Vengadeswaran, V.; Sidik, A. S. M.; Leong, Y. W.; Singh, A. [INTI University College, Nilai 71800 (Malaysia)

    2010-05-15

    The static (unloaded) electrical parameters of a capacitor bank are of utmost importance for the purpose of modeling the system as a whole when the capacitor bank is discharged into its dynamic electromagnetic load. Using a physical short circuit across the electromagnetic load is usually technically difficult and is unnecessary. The discharge can be operated at the highest pressure permissible in order to minimize current sheet motion, thus simulating zero dynamic load, to enable bank parameters, static inductance L{sub 0}, and resistance r{sub 0} to be obtained using lightly damped sinusoid equations given the bank capacitance C{sub 0}. However, for a plasma focus, even at the highest permissible pressure it is found that there is significant residual motion, so that the assumption of a zero dynamic load introduces unacceptable errors into the determination of the circuit parameters. To overcome this problem, the Lee model code is used to fit the computed current trace to the measured current waveform. Hence the dynamics is incorporated into the solution and the capacitor bank parameters are computed using the Lee model code, and more accurate static bank parameters are obtained.

  6. The thermal evolution of targets under plasma focus pulsed ion implantation

    International Nuclear Information System (INIS)

    Sanchez, G.; Feugeas, J.

    1997-01-01

    Pulsed ion beam implantation with plasma focus has proved to be an effective method of metal surface treatment for tribological purposes. Nevertheless, the pulsed nature and the continuous energy spectrum of the ion beams differ from those of the standard ion implantation processes. In this paper a model of the thermal evolution of the surface layers of stainless steel, titanium and copper, during and after nitrogen and argon ion beam incidence, is presented using the finite-difference method. In the calculations, the geometry and physical characteristics of the ion beams, the single-ion-solid interaction process and the thermal properties of the materials were used. The results showed a strong thermal effect consisting in the generation of transitory heating slopes and heating speeds as high as ∼3600 K μm -1 and ∼40 K ns -1 respectively, with maximum temperatures that can reach even the material evaporation point at the surface layers. The cooling down process, through the thermal conduction mechanism at the target bulk, turns out to be fast enough to produce the complete thermal relaxation of the target in only a few microseconds after the end of the ion beam incidence. The results presented are contrasted with experiments performed in similar conditions to those used in the numerical model. (Author)

  7. Development and experimental study of oil-free capacitor module for plasma focus device

    Science.gov (United States)

    Sharma, Ravindra Kumar; Sharma, Archana

    2017-03-01

    This development is concerned with the compact capacitor module for a plasma focus device. Oil-free, non-standard geometry capacitors are designed and developed for high current delivery in sub-microseconds time. Metalized dielectric film based pulse capacitor becomes progressively less viable at currents above 10 kA. It is due to reliability and energy scaling difficulties, based on effects such as vaporization, high resistivity, and end connection. Bipolar electrolytic capacitors are also not preferred due to their limited life and comparatively low peak current delivery. Bi-axially oriented polypropylene (BOPP) film with extended aluminum foil is a combination to deliver moderately high power. But, electrically weak points, relative permittivity, and the edge gap margins have made its adoption difficult. A concept has been developed in lab for implementing the above combination in a less complex and costly manner. This paper concerns the development and testing process techniques for quite different hollow cylindrical, oil-free capacitors (4 μ F , 10 kV, 20 nH). Shot life of 1000 has been experimentally performed on the test bed at its rated energy density level. The technological methods and engineering techniques are now available and utilized for manufacturing and testing of BOPP film based oil-free capacitors.

  8. Response of inorganic materials to laser - plasma EUV radiation focused with a lobster eye collector

    Science.gov (United States)

    Bartnik, Andrzej; Fiedorowicz, Henryk; Jarocki, Roman; Kostecki, Jerzy; Szczurek, Miroslaw; Havlikova, Radka; Pína, Ladislav; Švéda, Libor; Inneman, Adolf

    2007-05-01

    A single photon of EUV radiation carries enough energy to break any chemical bond or excite electrons from inner atomic shells. It means that the radiation regardless of its intensity can modify chemical structure of molecules. It is the reason that the radiation even with low intensity can cause fragmentation of long chains of organic materials and desorption of small parts from their surface. In this work interaction of EUV radiation with inorganic materials was investigated. Different inorganic samples were irradiated with a 10 Hz laser - plasma EUV source based on a gas puff target. The radiation was focused on a sample surface using a lobster eye collector. Radiation fluence at the surface reached 30 mJ/cm2 within a wavelength range 7 - 20 nm. In most cases there was no surface damage even after several minutes of irradiation. In some cases there could be noticed discolouration of an irradiated surface or evidences of thermal effects. In most cases however luminescent and scattered radiation was observed. The luminescent radiation was emitted in different wavelength ranges. It was recorded in a visible range of radiation and also in a wide wavelength range including UV, VUV and EUV. The radiation was especially intense in a case of non-metallic chemical compounds.

  9. In situ determination of the static inductance and resistance of a plasma focus capacitor bank

    International Nuclear Information System (INIS)

    Saw, S. H.; Lee, S.; Roy, F.; Chong, P. L.; Vengadeswaran, V.; Sidik, A. S. M.; Leong, Y. W.; Singh, A.

    2010-01-01

    The static (unloaded) electrical parameters of a capacitor bank are of utmost importance for the purpose of modeling the system as a whole when the capacitor bank is discharged into its dynamic electromagnetic load. Using a physical short circuit across the electromagnetic load is usually technically difficult and is unnecessary. The discharge can be operated at the highest pressure permissible in order to minimize current sheet motion, thus simulating zero dynamic load, to enable bank parameters, static inductance L 0 , and resistance r 0 to be obtained using lightly damped sinusoid equations given the bank capacitance C 0 . However, for a plasma focus, even at the highest permissible pressure it is found that there is significant residual motion, so that the assumption of a zero dynamic load introduces unacceptable errors into the determination of the circuit parameters. To overcome this problem, the Lee model code is used to fit the computed current trace to the measured current waveform. Hence the dynamics is incorporated into the solution and the capacitor bank parameters are computed using the Lee model code, and more accurate static bank parameters are obtained.

  10. Self-Similar Nonlinear Dynamical Solutions for One-Component Nonneutral Plasma in a Time-Dependent Linear Focusing Field

    International Nuclear Information System (INIS)

    Qin, Hong; Davidson, Ronald C.

    2011-01-01

    In a linear trap confining a one-component nonneutral plasma, the external focusing force is a linear function of the configuration coordinates and/or the velocity coordinates. Linear traps include the classical Paul trap and the Penning trap, as well as the newly proposed rotating-radio- frequency traps and the Mobius accelerator. This paper describes a class of self-similar nonlinear solutions of nonneutral plasma in general time-dependent linear focusing devices, with self-consistent electrostatic field. This class of nonlinear solutions includes many known solutions as special cases.

  11. Study of self-focusing of Non Gaussian laser beam in a plasma with density variation using moment theory approach

    Science.gov (United States)

    Pathak, Nidhi; Kaur, Sukhdeep; Singh, Sukhmander

    2018-05-01

    In this paper, self-focusing/defocusing effects have been studied by taking into account the combined effect of ponder-motive and relativistic non linearity during the laser plasma interaction with density variation. The formulation is based on the numerical analysis of second order nonlinear differential equation for appropriate set of laser and plasma parameters by employing moment theory approach. We found that self-focusing increases with increasing the laser intensity and density variation. The results obtained are valuable in high harmonic generation, inertial confinement fusion and charge particle acceleration.

  12. Plasma apolipoprotein A5 and triglycerides in type 2 diabetes

    NARCIS (Netherlands)

    Dallinga-Thie, GM; Van Tol, A; Hattori, H; van Vark-van de Zee, LC; Jansen, H; Sijbrands, EJG

    Aims/hypothesis: Variation in the human apolipoprotein (APO) A5 gene (APOA5) is associated with elevated plasma triglycerides. However, data on the exact role of plasma concentrations of APOA5 in human triglyceride homeostasis are lacking. In the present study, we estimated plasma APOA5 levels in

  13. Regulatory focus and adherence to self-care behaviors among adults with type 2 diabetes.

    Science.gov (United States)

    Avraham, Rinat; Van Dijk, Dina; Simon-Tuval, Tzahit

    2016-09-01

    The aims of this study were, first, to test the association between regulatory focus of adults with type 2 diabetes and their adherence to two types of self-care behaviors - lifestyle change (e.g. physical activity and diet) and medical care regimens (blood-glucose monitoring, foot care and medication usage). Second, to explore whether a fit between the message framing and patients' regulatory focus would improve their intentions to adhere specifically when the type of behavior fits the patients' regulatory focus as well. A cross-sectional study was conducted among 130 adults with type 2 diabetes who were hospitalized in an academic medical center. The patients completed a set of questionnaires that included their diabetes self-care activities, regulatory focus, self-esteem and demographic, socioeconomic and clinical data. In addition, participants were exposed to either a gain-framed or a loss-framed message, and were then asked to indicate their intention to improve adherence to self-care behaviors. A multivariable linear regression model revealed that promoters reported higher adherence to lifestyle change behaviors than preventers did (B = .60, p = .028). However, no effect of regulatory focus on adherence to medical care regimens was found (B = .46, p = .114). In addition, preventers reported higher intentions to adhere to medical care behaviors when the message framing was congruent with prevention focus (B = 1.16, p = .023). However, promoters did not report higher intentions to adhere to lifestyle behaviors when the message framing was congruent with promotion focus (B = -.16, p = .765). These findings justify the need to develop tailor-made interventions that are adjusted to both patients' regulatory focus and type of health behavior.

  14. Influence of light absorption on relativistic self-focusing of Gaussian laser beam in cold quantum plasma

    Science.gov (United States)

    Patil, S. D.; Valkunde, A. T.; Vhanmore, B. D.; Urunkar, T. U.; Gavade, K. M.; Takale, M. V.

    2018-05-01

    When inter particle distance is comparable to the de Broglies wavelength of charged particles, quantum effects in plasmas are unavoidable. We have exploited an influence of light absorption on self-focusing of Gaussian laser beam in cold quantum plasma by considering relativistic nonlinearity. Nonlinear differential equation governing beam-width parameter has been established by using parabolic equation approach under paraxial and WKB approximations. The effect of light absorption on variation of beam-width parameter with dimensionless distance of propagation is presented graphically and discussed. It is found that light absorption plays vital role in weakening the relativistic self-focusing of laser beam during propagation in cold quantum plasma and gives reasonably interesting results.

  15. Stimulated Brillouin scattering reduction induced by self-focusing for a single laser speckle interacting with an expanding plasma

    International Nuclear Information System (INIS)

    Masson-Laborde, P. E.; Depierreux, S.; Loiseau, P.; Hüller, S.; Pesme, D.; Labaune, Ch.; Bandulet, H.

    2014-01-01

    The origin of the low level of stimulated Brillouin scattering (SBS) observed in laser-plasma experiments carried out with a single laser speckle is investigated by means of three-dimensional simulations and modeling in the limit when the laser beam power P is well above the critical power for ponderomotive self-focusing We find that the order of magnitude of the time averaged reflectivities, together with the temporal and spatial SBS localization observed in our simulations, are correctly reproduced by our modeling. It is observed that, after a short transient stage, SBS reaches a significant level only (i) as long as the incident laser pulse is increasing in amplitude and (ii) in a single self-focused speckle located in the low-density front part of the plasma. In order to describe self-focusing in an inhomogeneous expanding plasma, we have derived a new Lagrangian density describing this process. Using then a variational approach, our model reproduces the position and the peak intensity of the self-focusing hot spot in the front part of the plasma density profile as well as the local density depletion in this hot spot. The knowledge of these parameters then makes it possible to estimate the spatial amplification of SBS as a function of the laser beam power and consequently to explain the experimentally observed SBS reflectivity, considerably reduced with respect to standard theory in the regime of large laser beam power

  16. Ion beam extraction from a matrix ECR plasma source by discrete ion-focusing effect

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, Mihai

    2010-01-01

    -ECR plasma source [3] with transversal magnetic filter for electron temperature control. 12 ECR plasma cells are placed 7.5 cm apart on the top of a cubic chamber 40x40x40 cm3. Each cell can be controlled independently by tuning the injected microwave power. The discharge is operated at pressures below 1 m......Positive or negative ion beams extracted from plasma are used in a large variety of surface functionalization techniques such as implantation, etching, surface activation, passivation or oxidation. Of particular importance is the surface treatment of materials sensitive to direct plasma exposure...... due to high heath fluxes, the controllability of the ion incidence angle, and charge accumulation when treating insulating materials. Despite of a large variety of plasma sources available for ion beam extraction, there is a clear need for new extraction mechanisms that can make available ion beams...

  17. The role of the gas/plasma plume and self-focusing in a gas-filled capillary discharge waveguide for high-power laser-plasma applications

    CERN Document Server

    Ciocarlan, C.; Islam, M. R.; Ersfeld, B.; Abuazoum, S.; Wilson, R.; Aniculaesei, C.; Welsh, G. H.; Vieux, G.; Jaroszynski, D. A.; 10.1063/1.4822333

    2013-01-01

    The role of the gas/plasma plume at the entrance of a gas-filled capillary discharge plasma waveguide in increasing the laser intensity has been investigated. Distinction is made between neutral gas and hot plasma plumes that, respectively, develop before and after discharge breakdown. Time-averaged measurements show that the on-axis plasma density of a fully expanded plasma plume over this region is similar to that inside the waveguide. Above the critical power, relativistic and ponderomotive selffocusing lead to an increase in the intensity, which can be nearly a factor of 2 compared with the case without a plume. When used as a laser plasma wakefield accelerator, the enhancement of intensity can lead to prompt electron injection very close to the entrance of the waveguide. Self-focusing occurs within two Rayleigh lengths of the waveguide entrance plane in the region, where the laser beam is converging. Analytical theory and numerical simulations show that, for a density of 3.01018 cm3, the peak normalized...

  18. Enhanced relativistic self-focusing of Hermite-cosh-Gaussian laser beam in plasma under density transition

    International Nuclear Information System (INIS)

    Nanda, Vikas; Kant, Niti

    2014-01-01

    Enhanced and early relativistic self-focusing of Hermite-cosh-Gaussian (HChG) beam in the plasmas under density transition has been investigated theoretically using Wentzel-Kramers-Brillouin and paraxial ray approximation for mode indices m=0, 1, and 2. The variation of beam width parameter with normalized propagation distance for m=0, 1, and 2 is reported, and it is observed that strong self-focusing occurs as the HChG beam propagates deeper inside the nonlinear medium as spot size shrinks due to highly dense plasmas and the results are presented graphically. A comparative study between self-focusing of HChG beam in the presence and absence of plasmas density transition is reported. The dependency of beam width parameter on the normalized propagation distance for different values of decentered parameter “b” has also been presented graphically. For m=0 and 1, strong self-focusing is reported for b=1.8, and for m=2 and b=1.8, beam gets diffracted. The results obtained indicate the dependency of the self-focusing of the HChG beam on the selected values of decentered parameter. Moreover, proper selection of decentered parameter results strong self-focusing of HChG beam. Stronger self-focusing of laser beam is observed due to the presence of plasma density transition which might be very useful in the applications like the generation of inertial fusion energy driven by lasers, laser driven accelerators, etc

  19. Enhanced relativistic self-focusing of Hermite-cosh-Gaussian laser beam in plasma under density transition

    Energy Technology Data Exchange (ETDEWEB)

    Nanda, Vikas; Kant, Niti, E-mail: nitikant@yahoo.com [Department of Physics, Lovely Professional University, Phagwara 144411, Punjab (India)

    2014-04-15

    Enhanced and early relativistic self-focusing of Hermite-cosh-Gaussian (HChG) beam in the plasmas under density transition has been investigated theoretically using Wentzel-Kramers-Brillouin and paraxial ray approximation for mode indices m=0, 1, and 2. The variation of beam width parameter with normalized propagation distance for m=0, 1, and 2 is reported, and it is observed that strong self-focusing occurs as the HChG beam propagates deeper inside the nonlinear medium as spot size shrinks due to highly dense plasmas and the results are presented graphically. A comparative study between self-focusing of HChG beam in the presence and absence of plasmas density transition is reported. The dependency of beam width parameter on the normalized propagation distance for different values of decentered parameter “b” has also been presented graphically. For m=0 and 1, strong self-focusing is reported for b=1.8, and for m=2 and b=1.8, beam gets diffracted. The results obtained indicate the dependency of the self-focusing of the HChG beam on the selected values of decentered parameter. Moreover, proper selection of decentered parameter results strong self-focusing of HChG beam. Stronger self-focusing of laser beam is observed due to the presence of plasma density transition which might be very useful in the applications like the generation of inertial fusion energy driven by lasers, laser driven accelerators, etc.

  20. Waterspout as a special type of atmospheric aerosol dusty plasma

    Science.gov (United States)

    Rantsev-Kartinov, Valentin A.

    2004-11-01

    An analysis of databases of photographic images of oceanic surface revealed the presence of oceanic skeletal structures (OSS) [1] Rantsev-Kartinov V.A., Preprint . The OSSs presumably differ from the formerly found skeletal structures (SS) (Phys. Lett. A 306 (2002) 175) only by the fact that OSS are filled in with the closely packed blocks of a smaller size, up to thin, tens of microns-sized capillaries. The SSs in the Earth atmosphere were suggested [1] to be produced during atmospheric electricity activity by the volcanic-born dust. The fall-out of such SSs on the oceanic surface is a material source of OSS. Here we suggest that an OSS block [1] in the form of vertically oriented floating cylinder may be a stimulator of waterspout (WS). The main body of WS may be interpreted as a special type of atmospheric aerosol dusty plasma, and WS column - as a long-lived filament, being formed in the process of electric breakdown between the cloud and oceanic surface. The charged water drops aerosol may behave similar to microdust and lift upward to the cloud by the electrostatic force. With such a capillary&;electrostatic model of WS, it appears possible to interpret many effects related to WS.

  1. On the course of fusion processes occurring in the plasma focus - an investigation by using time-resolved neutron spectroscopy

    International Nuclear Information System (INIS)

    Schmidt, R.

    1987-01-01

    The plasma focus POSEIDON emits up to 2x10 11 neutrons during some 100 ns, if it is operated with deuterium. This very high neutron production cannot be explained by a thermal neutron production mechanism starting out from the measured values of temperature (about 1 KeV) and deuteron density (10 18 cm -3 ). There is no doubt, that there exist strong ''beam-target''-processes of the deuterons, which cause such a high suprathermal neutron production. The neutron emission of the plasma focus POSEIDON appears in two pulses, which are associated to the two main phases of the hot and dense plasma. The first is the pinch or quiescent phase, in which a stable plasma column over 100 or 150 ns exists. The second phase is characterized by turbulence processes and starts with the end of the stable phase with the on-set of the m=0-instabilities and ends with the decay of the plasma. Both phases of neutron production are studied by time-resolved analysis of the neutron anisotropy factor and by time and spatial-resolved measurements of the neutron emission. Hence it follows, that there exist during both phases different non thermal neutron production processes, which are caused by different deuteron acceleration mechanisms. To get information on these deuteron acceleration mechanisms it is appropriate to analyse the neutron spectra of the plasma focus, because the half-width and the shape of the measured spectra are related to the energy and the angular distribution of the accelerated deuterons. (orig./GG) [de

  2. Effect of inserted metal at anode tip on formation of pulsed X-ray emitting zone of plasma focus device

    Science.gov (United States)

    Miremad, Seyed Milad; Shirani Bidabadi, Babak

    2018-04-01

    The effect of the anode's insert material of a plasma focus device on the properties of X-ray emission zone was studied. Inserts were fabricated out of six different materials including aluminum, copper, zinc, tin, tungsten, and lead to cover a wide range of atomic numbers. For each anode's insert material at different gas pressures and different voltages, the shape of X-ray emission zone was recorded by three pinhole cameras, which were installed on sidewall and roof of the chamber of plasma focus device. The results indicated that by changing the gas pressure and the charge voltage of capacitor, the X-ray source of plasma focus emerges with different forms as a concentrated column or conical shape with sharp or cloudy edges. These structures are in the form of a combination of plasma emission and anode-tip emission with different intensities. These observations indicate that the material of the anode-tip especially affects the structure of X-ray emission zone.

  3. Ponderomotive and weakly relativistic self-focusing of Gaussian laser beam in plasma: Effect of light absorption

    Energy Technology Data Exchange (ETDEWEB)

    Patil, S. D., E-mail: sdpatilphy@gmail.com [Department of Physics, Devchand College, Arjunnagar, Dist.: Kolhapur 591 237 (India); Takale, M. V. [Department of Physics, Shivaji University, Kolhapur 416 004 (India)

    2016-05-06

    This paper presents an influence of light absorption on self-focusing of laser beam propagation in plasma. The differential equation for beam-width parameter is obtained using the Wentzel-Kramers-Brillouin and paraxial approximations through parabolic equation approach. The nonlinearity in dielectric function is assumed to be aroused due to the combined effect of weakly relativistic and ponderomotive regime. To highlight the nature of propagation, behavior of beam-width parameter with dimensionless distance of propagation is presented graphically and discussed. The present work is helpful to understand issues related to the beam propagation in laser plasma interaction experiments where light absorption plays a vital role.

  4. Dense plasma focus x-ray source for sub-micron lithography

    International Nuclear Information System (INIS)

    Prasad, R.R.; Krishnan, M.; Mangano, J.; Greene, P.; Qi, Niansheng

    1993-01-01

    A discharge driven, dense plasma focus in neon is under development at SRL for use as a point x-ray source for sub-micron lithography. This source is presently capable of delivering ∼ 13j/pulse of neon K-shell x-rays (8--14 angstrom) into 4π steradians with 2 kj of electrical energy stored in the capacitor bank charged to 9 kV at a pulse repetition rate of 2 Hz. The discharge is produced by a ≤4 kj, ≤12 kV, capacitor bank circuit, which has a fixed inductance of 12 nH and drives ≤450 kA currents into the DPF load, with ∼1.1 μs rise-times. X-rays are produced when a dense pinch of neon is formed along the axis of the DPF electrodes. A new rail-gap switched capacitor bank and DPF have been built, designed for continuous operation at 2 Hz and burst mode operation at 20 Hz. This paper will present measurements of the x-ray output at a repetition rate of 2 Hz using the new capacitor bank. It will also describe measurements of the spot size (0.3--0.8 mm) and the spectrum (8--14 angstrom) of the DPF source. The dependence of these parameters on the DPF head geometry, bank energy and operating pressure will be discussed. The x-ray output has been measured using filtered pin diodes, x-ray diodes, and absolutely calibrated x-ray crystal spectra. Results from the source operating at 2 Hz will be presented. A novel concept of a windowless beamline has also been developed. The results of preliminary experiments to test the concept will be discussed. At a pulse repetition rate of 20 Hz, this source should produce 200--400 W of x-ray power in the 8-14 angstrom wavelength band, with an input power of 40--60 kW

  5. Development of Diagnostics for Large-Scale Experiments with Dense Magnetized Plasmas - MJ Plasma-focus diagnostics systems

    Energy Technology Data Exchange (ETDEWEB)

    Scholz, M.; Karpinski, L.; Paduch, M.; Pisarczyk, T.; Zielinska, E.; Chodukowski, T. [Institute of Plasma Physics and Laser Microfusion IPPLM, 01-497 Warsaw (Poland); Sadowski, M.J. [Institute of Plasma Physics and Laser Microfusion IPPLM, 01-497 Warsaw (Poland)] [The Andrzej Soltan Institute for Nuclear Studies IPJ, 05-400 Otwock-Swiert (Poland); Skladnik-Sadowska, E.; Czaus, K.; Kwiatkowski, R.; Malinowski, K. [The Andrzej Soltan Institute for Nuclear Studies IPJ, 05-400 Otwock-Swiert (Poland); Krauz, S. [RNC Kurchatov Institute, Moscow (Russian Federation); Mitrovanov, K. [FGUP GNC RF Triniti, Troick (Russian Federation)

    2011-07-01

    This document presents the diagnostics arrangements and interesting results of research on fusion pulsed plasma, which was generated within the large PF-1000 facility operated in the Institute of Plasma Physics and Laser Microfusion (Warsaw, Poland). Experimental studies were carried out with the following diagnostic techniques: 1) Rogovski coil for current measurements; 2) Four dI/dt probes in different places around the collector of PF-1000; 3) Voltage divider; 4) Mach-Zender interferometer (16 frames); 5) Fast scintillation probes for X-ray and neutron detection; 6) Silver activation counters; 7) Specially prepared current probes; 8) Thomson spectrometer for mass- and energy-analysis of deuterium beams; 9) Ion-pinhole cameras equipped with nuclear-track detectors, etc. The studies have been carried out with the pure deuterium filling, and particular attention was paid to correlations between the fast-neutron emission and an evolution of plasma parameters. The total fusion-neutron yield, as measured with four silver-activation counters, was found to be up to 7*10{sup 11} per shot, depending on the experimental conditions. Correlations of the neutron pulses with interferometric frame-pictures of the PF pinch column were studied. From time-of-flight (ToF) measurements of the fusion neutrons it was possible to estimate a CM velocity of deuterons involved in the D-D reactions. The fast fusion-produced protons have also been recorded and analyzed by means pinhole cameras and shielded track detectors. The document is composed of an abstract followed by the slides of the presentation. (authors)

  6. Surface modification study of zirconium on exposure to fusion grade plasma in an 11.5 kJ plasma focus device

    International Nuclear Information System (INIS)

    Srivastava, Rohit; Niranjan, Ram; Rout, R.K.; Kaushik, T.C.; Chakravarthy, Y.; Mishra, P.

    2017-01-01

    In continuation of our investigation on effect of fusion grade plasma produced in an existing MEPF-12 (11.5 kJ, 40 μF, 24 kV) plasma focus (PF) facility on different materials, likely to be used in future fusion reactors, we have reported here the study on Zirconium (Zr) metal. In the present work, the Zr sample in disc (2 mm thick, 10 mm diameter) form was exposed to twenty shots of plasma focus operated at 4 mbar deuterium gas filling pressure and 11.5 kJ bank energy. The samples were placed at a distance of 6 cm from the tip of the anode in the MEPF-12 PF device. The emissions from the device comprise of deuterium ions in wide energy range (a few keV to several hundreds of keV), high temperature plasma (in general a few keV) and neutrons of 2.45 MeV energy produced due to D(D, 3 He)n fusion reactions

  7. Preliminary results on a 4 kJ, 140 k A plasma focus; Resultados preliminares en un plasma foco de 4 KJ

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Patricio; Favre, Mario; Chuaqui, Hernan; Wyndham, Edmund [Pontificia Univ. Catolica de Chile, Santiago (Chile). Facultad de Fisica

    1997-12-31

    Preliminary results on the operation of a 4 kJ, 140 kA Plasma Focus device are presented. The machine operates Hydrogen and Hydrogen-Argon mixtures at pressures between 400 m Torr to 10 Torr. Main diagnostics include electric and current measurements, time and space resolved X-ray observations, with limited spectral resolution, and B-dot sensors to monitor the evolution of de current sheet during the run up phase of the discharge. The results indicate that good focus is obtained in the above pressure range. This is inferred from I-dot traces and Pin diode and pin-hole camera X-ray observations. The B-dot loops suggest that a symmetric current sheet is produced. These results show that the machine exhibits a reliable performance, which allows further studies on dense transient plasmas to be developed. (author). 5 refs., 5 figs.

  8. Scaling Laws of Nitrogen Soft X-Ray Yields from 1 to 200 kJ Plasma Focus

    International Nuclear Information System (INIS)

    Akel, M.; Lee, S.

    2013-01-01

    Numerical experiments are carried out systematically to determine the nitrogen soft x-ray yield for optimized nitrogen plasma focus with storage energy E 0 from 1 kJ to 200 kJ. Scaling laws on nitrogen soft x-ray yield, in terms of storage energies E 0 , peak discharge current I p eak and focus pinch current I p inch were found. It was found that the nitrogen x-ray yields scales on average with y s xr, N= 1.93xE o 1 .21 J (E 0 in kJ) with the scaling showing gradual deterioration as E 0 rises over the range. A more robust scaling is y s xr = 8x10 - 8I 0 3.38 p inch . The optimum nitrogen soft x-ray yield emitted from plasma focus is found to be about 1 kJ for storage energy of 200 kJ. This indicates that nitrogen plasma focus is a good water-window soft x-ray source when properly designed. (author)

  9. Low plasma aldosterone despite normal plasma renin activity in uncomplicated type 1 diabetes mellitus : effects of RAAS stimulation

    NARCIS (Netherlands)

    Luik, PT; Kerstens, MN; Hoogenberg, K; Navis, GJ; Dullaart, RPF

    Background Data on levels and responsiveness of PRA and aldosterone in type 1 diabetes mellitus are conflicting. Earlier studies were not standardized with respect to the type of diabetes mellitus, the presence of diabetic complications or sodium intake. Therefore, we studied plasma renin activity

  10. Detection of x-rays emitted from a plasma focus device with energy of 2.8 KJ, and its applications in plasma diagnostic and radiography

    International Nuclear Information System (INIS)

    AL-Hawat, Sh.; Akel, M.

    2011-06-01

    The local plasma focus device was modified by replacing the old capacitors (25μF,20 kV ,1.43μH ) and the open spark gap by new capacitors with (25μF,20 kV ,200 nH ) and a new closed spark gap, so instead of a current of 50 kA as a maximum value we obtained a maximum current about 120 kA. The modified device is capable now to generate x-rays, which was confirmed by taking some radiographies for metallic pieces, electronic elements and others . In addition to that some diagnostics were carried out on the device using Ohm voltage divider to record voltage curves, Rogovskii coil for measuring the current, and five channel diodes to evaluate the temporal evolution of x-rays generated in the device working on argon vs. pressure and voltage. The generation of the soft x-ray emission in a low energy 2.8 kJ plasma focus device operated with argon using a detector of five PIN-Si BPX-65 diodes filtered with different foils of Mylar, Al and Cu. Spectral analysis using the recorded x-ray signals ratio method shows that there are two components in the x-ray emissions: one arising from the focused argon plasma with temperature of 2.5 keV and the other arising from the electron beam activity on copper anode, where the second component is predominant in most of investigated experiments due to the used of solid anode. Numerical experiments were carried out using five phases radiative Lee model RADPF5.15d-dd with N 2 , O 2 , Ar, Ne gases on plasma focus device AECS PF1-2 (or PF SY1-2) for its characterization and soft x-ray optimization. (author)

  11. Measurement of electron- and ion beam energies and currents in a plasma focus discharge

    International Nuclear Information System (INIS)

    Yamamoto, Toshikazu; Kondoh, Yoshiomi; Shimoda, Katsuji; Hirano, Katsumi

    1982-01-01

    Measurements of energetic particle beams in a plsma focus with a Mather type device are presented. Rogowski coils are used for time-resolved measurement, and solid-state nuclear track detectors for time-integrated measurement of the beams. In the upstream direction with respect to the discharge current, only the electron beam with the maximum current of several kA was detected, which was approximately one percent of the discharge current. The electron energies of the beam were spread from 0.1 to 1 MeV. In the downstream direction, two successive emissions of ions were observed. The first emission had an extremely high energy of the order of some MeV and a low beam current of less than 10 A. The second emission, the main part of the ion beam, with energies of 100 - 800 keV, followed the first one with a time lag of several tens of nanoseconds, and the beam current reached several tens of amperes. (author)

  12. Self-focusing, self modulation and stability properties of laser beam propagating in plasma: A variational approach

    International Nuclear Information System (INIS)

    Kaur, Ravinder; Gill, Tarsem Singh; Mahajan, Ranju

    2010-01-01

    Laboratory as well as Particle in cell (PIC) simulation experiments reveal the strong flow of energetic electrons co-moving with laser beam in laser plasma interaction. Equation governing the evolution of complex envelope in slowly varying envelope approximation is nonlinear parabolic equation. A Lagrangian for the problem is set up and assuming a trial Gaussian profile, we solve the reduced Lagrangian problem for beam width and curvature. Besides self-focusing and self-modulation of laser beam, we observe that stability properties of such plasma system are studied about equilibrium values using this variational approach. We obtained an eigen value equation, which is cubic in nature and investigated the criterion for stability using Hurwitz conditions for laser beam plasma system.

  13. Z-Pinch at extreme energies: Nanofocus of less than 1J. Plasma Focus of 400 J. Gas embedded Z-pinch operating at MA

    International Nuclear Information System (INIS)

    Pavez Morales, Cristian A

    2007-01-01

    anisotropic of 42.5% of the total production of neutrons is obtained with this technique. Finally, the average energy and the spectral distribution of neutrons at 900 from the axis of the pinch were measured by using the time of flight technique and an array of photomultipliers where it is possible to observe a maximum in the distribution around 2.5 MeV and a second diffused peak around 2.8 MeV. The Nanofocus device was electrically characterized. The plasma dynamics was studied by means of ultrafast photography in the visible spectrum reporting the formation of a dynamic coaxial discharge (plasma focus type) which is characterized by the formation and subsequent breaking of plasma column over the anode. The emission of radiation was studied by means of X-rays detection techniques with and without time resolution. From the signals of the photomultiplier, x-ray emission starts in the moment of the electrical break, and the maximum emission is previous to the moment of maximum current. An effective energy for radiation of 4.2keV is obtained from the detection technique with photography film and stepped filters. In the gas embedded Z-pinch experiment, a couple of conical electrodes were used to determine a preferential area of electrical break in the gas and then to form the discharge channel. The information of the channel structure, the same as its electronic density, was obtained using refractive optical techniques. A singularity was observed near to the cathode with a electronic density of the order of 4x10 24 m -3 immersed in a plasma column of density of the order of 1x10 24 m -3 . For those discharges where the formation of the plasma channel was well defined, it is possible to observe compression of the column and 3 He detectors give signals corresponding up to 5 x 10 5 neutrons per pulse. Moreover, macroscopic instabilities are not observed during the time in which the discharge is studied by means of optical diagnosis. With this, it is obtained that times of stability

  14. Dense Plasma Focus: physics and applications (radiation material science, single-shot disclosure of hidden illegal objects, radiation biology and medicine, etc.)

    Science.gov (United States)

    Gribkov, V. A.; Miklaszewski, R.; Paduch, M.; Zielinska, E.; Chernyshova, M.; Pisarczyk, T.; Pimenov, V. N.; Demina, E. V.; Niemela, J.; Crespo, M.-L.; Cicuttin, A.; Tomaszewski, K.; Sadowski, M. J.; Skladnik-Sadowska, E.; Pytel, K.; Zawadka, A.; Giannini, G.; Longo, F.; Talab, A.; Ul'yanenko, S. E.

    2015-03-01

    The paper presents some outcomes obtained during the year of 2013 of the activity in the frame of the International Atomic Energy Agency Co-ordinated research project "Investigations of Materials under High Repetition and Intense Fusion-Relevant Pulses". The main results are related to the effects created at the interaction of powerful pulses of different types of radiation (soft and hard X-rays, hot plasma and fast ion streams, neutrons, etc. generated in Dense Plasma Focus (DPF) facilities) with various materials including those that are counted as perspective ones for their use in future thermonuclear reactors. Besides we discuss phenomena observed at the irradiation of biological test objects. We examine possible applications of nanosecond powerful pulses of neutrons to the aims of nuclear medicine and for disclosure of hidden illegal objects. Special attention is devoted to discussions of a possibility to create extremely large and enormously diminutive DPF devices and probabilities of their use in energetics, medicine and modern electronics.

  15. Plasma-based creation of short light pulses: analysis and simulation of amplification and focusing

    Czech Academy of Sciences Publication Activity Database

    Riconda, C.; Weber, Stefan A.; Lancia, L.; Marqués, J.-R.; Mourou, G.; Fuchs, J.

    2015-01-01

    Roč. 57, č. 1 (2015), s. 014002 ISSN 0741-3335 R&D Projects: GA MŠk ED1.1.00/02.0061; GA MŠk EE2.3.20.0279 Grant - others:ELI Beamlines(XE) CZ.1.05/1.1.00/02.0061; LaserZdroj (OP VK 3)(XE) CZ.1.07/2.3.00/20.0279 Institutional support: RVO:68378271 Keywords : plasma-based amplification * PIC simulations * parametric instabilities Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.404, year: 2015

  16. Using FLUKA to Study Concrete Square Shield Performance in Attenuation of Neutron Radiation Produced by APF Plasma Focus Neutron Source

    Science.gov (United States)

    Nemati, M. J.; Habibi, M.; Amrollahi, R.

    2013-04-01

    In 2010, representatives from the Nuclear Engineering and physics Department of Amirkabir University of Technology (AUT) requested development of a project with the objective of determining the performance of a concrete shield for their Plasma Focus as neutron source. The project team in Laboratory of Nuclear Engineering and physics department of Amirkabir University of Technology choose some shape of shield to study on their performance with Monte Carlo code. In the present work, the capability of Monte Carlo code FLUKA will be explored to model the APF Plasma Focus, and investigating the neutron fluence on the square concrete shield in each region of problem. The physical models embedded in FLUKA are mentioned, as well as examples of benchmarking against future experimental data. As a result of this study suitable thickness of concrete for shielding APF will be considered.

  17. Effect of self-focusing on resonant third harmonic generation of laser in a rippled density plasma

    International Nuclear Information System (INIS)

    Kaur, Sukhdeep; Sharma, A. K.; Yadav, Sushila

    2010-01-01

    Resonant third harmonic generation by a Gaussian laser beam in a rippled density plasma is studied. The laser ponderomotive force induces second harmonic longitudinal velocity on electrons that couples with the static density ripple to produce a density perturbation at 2ω,2k+q, where ω and k are the frequency and wave number of the laser and q is the ripple wave number of the laser. This density perturbation beats with electron oscillatory velocity at ω,k-vector to produce a nonlinear current driving the third harmonic generation. In the regime of quadratic nonlinearity, the self-focusing of the laser enhances the third harmonic power. However, at higher intensity, plasma density is significantly reduced on the axis, detuning the third harmonic resonance and weakening the harmonic yield. Self-focusing causes enhancement in the efficiency of harmonic generation.

  18. Elevated plasma homocysteine in type 2 diabetes mellitus: a risk ...

    African Journals Online (AJOL)

    The fasting plasma glucose (p<0.01), tHcy (p<0.02), and triglyceride (p<0.03) were significantly higher in the diabetes group when compared with the corresponding control values. The plasma folic acid and vitamin B12 (p<0.05) were significantly reduced compared to the control values. The tHcy (p<0.01) was significantly ...

  19. Plasma properties of a modified beam-plasma type ion source

    International Nuclear Information System (INIS)

    Ishikawa, Junzo; Sano, Fumimichi; Tsuji, Hiroshi; Ektessabi, A.M.; Takagi, Toshinori

    1978-01-01

    The properties of the plasma produced by beam-plasma discharge were experimentally investigated. The ion source used for this work consists of three parts, that is, the ion-extracting region with an electron gun, the drift space and the collector region. Primary and secondary electron beams are injected in to the drift tube. The interaction between plasma and these electron beams causes production of high density plasma by virtue of the beam-plasma discharge. The gas inlet is located in the middle of the drift tube, so that the gas conductance is high. The energy of the primary and secondary electron beams is transferred to that microwaves through beam-plasma interaction. The microwaves heat the plasma electrons by the cyclotron resonance or other mechanism. The amount of the energetic plasma electrons is much larger than that of the beam electrons, so that neutral gas is ionized. The density of the produced plasma is 10 2 or 10 3 times as large as the plasma produced by impact ionization. With a probe located in the middle of the drift tube, the plasma density and the electron temperature can be measured, and the power and spectra of the microwaves can be detected. The microwave oscillation, the primary electron beam characteristics, and the gas pressure characteristics were studied. Larger current of the high energy primary of secondary electron beam is required for the effective discharge. The ion source has to be operated at the minimum gas pressure. The length of beam-plasma interaction and the magnetic field intensity in the drift tube are also important parameters. (Kato, T.)

  20. Application of plasma focus installations for a study of the influence ...

    Indian Academy of Sciences (India)

    The appearance of a large number of cracks on the surface of vanadium under the impulse influence of deuterium plasma shows that pure vanadium cannot be used for the construction of thermonuclear fusion reactors. Such PF installations could also be used effectively for the study of other material and construction ...

  1. Characteristics of ion spectrum in a low energy nitrogen operated plasma focus: application to the metallic substrates thermal treatment

    International Nuclear Information System (INIS)

    Kelly, H.; Lepone, A.; Marquez, A.

    1998-01-01

    Full text: This work presents the nitrogen ion spectrum characteristics in a Plasma Focus device, determined using a Thomson spectrometer and a Faraday cup, operated in the secondary electron collective mode. It is also discussed the thermal treatment and the re coating induce by ions incident on a metallic surface (AISI 304 steel) placed in front of the coaxial gun, when the device is operated with a Ti implant at the end of the central electrode

  2. Experimental study on the optimization for neutron emission in a small fast plasma focus operated at tens of Joules

    International Nuclear Information System (INIS)

    Tarifeno-Saldivia, A; Soto, L

    2014-01-01

    This work reports results of a systematic experimental study dealing with the optimization for neutron emission of the PF-50J plasma focus. The device was operated in a repetitive mode at repetition rates of 0.1-0.5 Hz. Optimal configurations, neutron emission rates, observed anisotropy, analysis and contrast of 'good' and 'bad' shots are currently presented. Additionally, engineering aspects on the neutron emission were also studied, such as contaminants removal circuit and chamber design.

  3. Effects of gas chamber geometry and gas flow on the neutron production in a fast plasma focus neutron source

    International Nuclear Information System (INIS)

    Tarifeño-Saldivia, Ariel; Soto, Leopoldo

    2014-01-01

    This work reports that gas chamber geometry and gas flow management substantially affect the neutron production of a repetitive fast plasma focus. The gas flow rate is the most sensitive parameter. An appropriate design of the gas chamber combined with a suitable flow-rate management can lead to improvements in the neutron production of one order of magnitude working in a fast repetitive mode. (paper)

  4. Plasma amino acid profiles are associated with insulin, C-peptide and adiponectin levels in type 2 diabetic patients

    OpenAIRE

    Nakamura, H; Jinzu, H; Nagao, K; Noguchi, Y; Shimba, N; Miyano, H; Watanabe, T; Iseki, K

    2014-01-01

    Objectives: Plasma-free amino acid (PFAA) profiles have been associated with a future risk of developing diabetes or cardiovascular disease in nondiabetic subjects. These PFAA alterations might predominantly result from the metabolic shift caused by insulin resistance and visceral fat deposition. The variety of PFAA profiles within diabetic subjects is not well researched. In this study, we focused on type 2 diabetic subjects and examined the association between PFAA profiles and insulin- and...

  5. Analysis of behavior of focusing error signals generated by astigmatic method when a focused spot moves beyond the radius of a land-groove-type optical disk

    Science.gov (United States)

    Shinoda, Masahisa; Nakatani, Hidehiko; Nakai, Kenya; Ohmaki, Masayuki

    2015-09-01

    We theoretically calculate behaviors of focusing error signals generated by an astigmatic method in a land-groove-type optical disk. The focusing error signal from the land does not coincide with that from the groove. This behavior is enhanced when a focused spot of an optical pickup moves beyond the radius of the optical disk. A gain difference between the slope sensitivities of focusing error signals from the land and the groove is an important factor with respect to stable focusing servo control. In our calculation, the format of digital versatile disc-random access memory (DVD-RAM) is adopted as the land-groove-type optical disk model, and the dependences of the gain difference on various factors are investigated. The gain difference strongly depends on the optical intensity distribution of the laser beam in the optical pickup. The calculation method and results in this paper will be reflected in newly developed land-groove-type optical disks.

  6. The desing study of high voltage plasma focus for a large fluence neutron source by using a water capacitor bank

    International Nuclear Information System (INIS)

    Ueno, Isao; Kobata, Tadasuke

    1983-01-01

    A new possibility for high intensity neutron source (HINS) would be opened by the plasma focus device if we have a high voltage capacitor bank. A scaling law of neutron yield for D-T gas discharge in plasma focus device is obtained after Imshennik, Filippov and Filippova. The resulting scaling law shows the realizability of the D-T HINS by the use of plasma focus, provided that the device is operated under a high voltage condition. Until now, it has been difficult to construct the high voltage capacitor bank of long life, for example with V 0 =300kV, C 0 =200μF and L 0 --5nH necessary in the level of HINS. It becomes possible to design this capacitor bank by using the coaxial water capacitor which has been developed for the electron and ion beam accelerator. The size of a capacitor designed for V 0 =300kV, C 0 =1μF is phi5m x 22m. Two hundred capacitors are used in parallel in order to get the 200μF. (author)

  7. Comparative analysis of turbulent effects on thermal plasma characteristics inside the plasma torches with rod- and well-type cathodes

    International Nuclear Information System (INIS)

    Hur, Min; Hong, Sang Hee

    2002-01-01

    The thermal plasma characteristics inside the two non-transferred plasma torches with rod-type cathode (RTC) and well-type cathode (WTC) are analysed in conjunction with turbulent effects on them in the atmospheric-pressure conditions. A control volume method and a modified semi-implicit pressure linked equations revised algorithm are used for solving the governing equations, i.e. conservation equations of mass, momentum, and energy together with a current continuity equation for arc discharge. A cold flow analysis is introduced to find the cathode spot position in the WTC torch, and both the laminar and turbulent models are employed to gain a physical insight into the turbulent effects on the thermal plasma characteristics produced inside the two torches. The numerical analysis for an RTC torch shows that slightly different values of plasma temperature and velocity between the laminar and turbulent calculations occur and the radial temperature profiles are constricted at the axis with increasing the gas flow rate, and that the large turbulent viscosities appear mostly near the anode wall. These calculated results indicate that the turbulent effects on the thermal plasma characteristics are very weak in the whole discharge region inside the RTC torch. On the other hand, the calculated results of the two numerical simulations for a WTC torch present that the significantly different values of plasma characteristics between the two models appear in the whole torch region and the plasma temperatures decrease with increasing the gas flow rate because the relatively strong turbulent effects are prevailing in the entire interior region of the WTC torch. From the comparisons of plasma net powers calculated and measured in this work, the turbulent modelling turns out to provide the more accurately calculated results close to the measured ones compared with the laminar one, especially for the torch with WTC. This is because the turbulent effects are considerably strong in

  8. Type I parametric down conversion of highly focused Gaussian beams in finite length crystals

    International Nuclear Information System (INIS)

    Jeronimo-Moreno, Yasser; Jáuregui, R

    2014-01-01

    This paper presents a study of the correlations in wave vector space of photon pairs generated by type I spontaneous parametric down conversion using a Gaussian pump beam. The analysis covers both moderate focused and highly focused regimes, paying special attention to the angular spectrum and the conditional angular spectrum. Simple analytic expressions are derived that allow a detailed study of the dependence of these spectra on the waist of the source and the length of the nonlinear crystal. These expressions are in good agreement with numerical expectations and reported experimental results. They are used to make a systematic search of optimization parameters that improve the feasibility of using highly focused Gaussian beams to generate idler and signal photons with predetermined mean values and spread of their transverse wave vectors. (papers)

  9. Re-appraisal and extension of the Gratton-Vargas two-dimensional analytical snowplow model of plasma focus evolution in the context of contemporary research

    International Nuclear Information System (INIS)

    Auluck, S. K. H.

    2013-01-01

    Recent resurgence of interest in applications of dense plasma focus and doubts about the conventional view of dense plasma focus as a purely irrotational compressive flow have re-opened questions concerning device optimization. In this context, this paper re-appraises and extends the analytical snowplow model of plasma focus sheath evolution developed by F. Gratton and J. M. Vargas [Energy Storage, Compression and Switching, edited by V. Nardi, H. Sahlin, and W. H. Bostick (Plenum, New York, 1983), Vol. 2, p. 353)] and shows its relevance to contemporary research. The Gratton-Vargas (GV) model enables construction of a special orthogonal coordinate system in which the plasma flow problem can be simplified and a model of sheath structure can be formulated. The Lawrenceville Plasma Physics (LPP) plasma focus facility, which reports neutron yield better than global scaling law, is shown to be operating closer to an optimum operating point of the GV model as compared with PF-1000

  10. Comment on “Stationary self-focusing of Gaussian laser beam in relativistic thermal quantum plasma” [Phys. Plasmas 20, 072703 (2013)

    International Nuclear Information System (INIS)

    Habibi, M.; Ghamari, F.

    2014-01-01

    Patil and Takale in their recent article [Phys. Plasmas 20, 072703 (2013)], by evaluating the quantum dielectric response in thermal quantum plasma, have modeled the relativistic self-focusing of Gaussian laser beam in a plasma. We have found that there are some important shortcomings and fundamental mistakes in Patil and Takale [Phys. Plasmas 20, 072703 (2013)] that we give a brief description about them and refer readers to important misconception about the use of the Fermi temperature in quantum plasmas, appearing in Patil and Takale [Phys. Plasmas 20, 072703 (2013)

  11. Dynamics of hot spots in the DPF-78 plasma focus from x-ray spectra and REB emission

    International Nuclear Information System (INIS)

    Schmidt, H.; Wang, X.X.

    1995-01-01

    The X-ray emission from hot spots in the plasma focus DPF-78 was investigated with the help of two X-ray quartz crystal spectrometers of the Johann type and a 4 fold magnifying X-ray pinhole camera. In the experiments the working gas was chosen to be 300 Pa deuterium with 20 Pa argon admixture. X-ray spectra in the wavelength range from 3.55 angstrom to 4.0 angstrom, including H-like and He-like Argon lines, were recorded on Kodak DEF-2 film. From the spatially resolved spectra recorded side-on, a relative spectral shift between different hot spots of the same shot was often observed. The shift could be attributed to the Doppler shift. From spectral characteristics such as intensities and FWHM of Ar resonant and intercombination lines electron densities of up to 3 x 10 27 m -3 were determined. Radial dimensions of the hot spots ranging from about 140 microm to 300 microm were found from pinhole pictures applying the penumbra method. Usually two pulses of relativistic electron beams were observed using Cherenkov detectors in a magnetic spectrometer. The energy of the first pulse, which was emitted at the time of maximum compression, was higher than that of the second pulse. The measured FWHM of the REB pulses ranges from 3 ns to about 10 ns. The characteristics of the time-integrated X-ray spectra and the time resolved REB spectra and their dependence on the composition of the filling gas are discussed

  12. Prototype for Internet support of pregnant women and mothers with type 1 diabetes: focus group testing

    Directory of Open Access Journals (Sweden)

    Adolfsson A

    2012-08-01

    Full Text Available Annsofie Adolfsson,1,2 Malin Jansson1,21School of Life Sciences, University of Skovde, Skovde, Sweden; 2Department of Obstetrics and Gynaecology, Skaraborg Hospital, Skovde, SwedenBackground: The aim of this study was to pilot test a prototype website called MODIAB-web designed to support pregnant women and mothers with type 1 diabetes.Method: A focus group was undertaken and the results were analyzed using qualitative content analysis.Results: Eight subthemes were identified, comprising "blood glucose versus insulin," "application for smart phones," "the time aspect," "interface and technology," "forum," "direct link to the diabetes midwife," "ask the expert," and "lack of contact information." These subthemes were condensed into two main themes. The first theme was "easily understood interface, but in need of a more blood-glucose focused orientation" and the second theme was "forum for interaction with both equals and experts." Conclusion: The women in this study had positive impressions of several of the MODIAB-web functions, including a forum for pregnant mothers with type 1 diabetes and the possibility of being able to put their blood glucose levels into a diagram which could be sent directly to the diabetes midwife. Access to articles and information via the "fact" tab and the ability to ask questions of experts were also significantly helpful to women in the focus group. Pregnant women and mothers with type 1 diabetes can gain support from such a Web-based self-help system.Keywords: type 1 diabetes, web support, pregnancy, focus group interview

  13. TuFF3. Self-focusing in underdense ultraviolet laser-produced plasmas

    International Nuclear Information System (INIS)

    Tanaka, K.; Boswell, B.; Craxton, R.S.; Goldman, L.M.; Richardson, M.C.; Seka, W.; Short, R.W.; Soures, J.M.

    1984-01-01

    Ultraviolet laser-matter interaction processes are of considerable interest to laser fusion. Among these processes, filamentation (or self-focusing) is of particular importance, since it could prevent attainment of the illumination uniformity required for high target compression. In addition self-focusing may complicate the interpretation of target interaction experiments. Self-focusing has been studied experimentally by side-on x-ray pinhole camera photography and backscatter spectrometry. These results are compared with two-dimensional simulations using the hydro code SAGE, which is well suited to model thermal self-focusing (no ponderomotive forces are included in these simulations)

  14. Analysis of waves in the plasma guided by a periodical vane-type slow wave structure

    International Nuclear Information System (INIS)

    Wu, T.J.; Kou, C.S.

    2005-01-01

    In this study, the dispersion relation has been derived to characterize the propagation of the waves in the plasma guided by a periodical vane-type slow wave structure. The plasma is confined by a quartz plate. Results indicate that there are two different waves in this structure. One is the plasma mode that originates from the plasma surface wave propagating along the interface between the plasma and the quartz plate, and the other is the guide mode that originally travels along the vane-type slow wave structure. In contrast to its original slow wave characteristics, the guide mode becomes a fast wave in the low-frequency portion of the passband, and there exists a cut-off frequency for the guide mode. The vane-type guiding structure has been shown to limit the upper frequency of the passband of the plasma mode, compared with that of the plasma surface wave. In addition, the passband of the plasma mode increases with the plasma density while it becomes narrower for the guide mode. The influences of the parameters of the guiding structure and plasma density on the propagation of waves are also presented

  15. Diffraction, self-focusing, and the geometrical optics limit in laser produced plasmas

    International Nuclear Information System (INIS)

    Marchand, R.; Rankin, R.; Capjack, C.E.; Birnboim, A.

    1987-01-01

    The effect of diffraction on the self-modulation of an intense laser beam in an initially uniform hydrogen plasma is investigated. A formalism is used in which the diffraction term in the paraxial wave equation can be arbitrarily reduced by the use of a weight factor iota. In the limit where iota approaches zero, it is shown that the paraxial wave equation correctly reduces to the geometrical optics limit and that the problem then becomes formally equivalent to solving the ray-tracing equations. When iota = 1, the paraxial wave equation takes its usual form and diffraction is fully accounted for. This formalism is applied to the simulation of self-modulation of an intense laser beam in a hydrogen plasma, for which diffraction is shown to be significant

  16. Proton acceleration: new developments for focusing and energy selection, and applications in plasma physics

    Science.gov (United States)

    Audebert, P.

    2007-11-01

    In the last few years, intense research has been conducted on laser-accelerated ion sources and their applications. These sources have exceptional properties, i.e. high brightness and high spectral cut-off, high directionality and laminarity, short burst duration. We have shown that for proton energies >10 MeV, the transverse and longitudinal emittance are respectively example point-projection radiography with unprecedented resolution. We will show example of such time and space-resolved radiography of fast evolving fields, either of associated with the expansion of a plasma in vacuum [*] or with the propagation of a ICF-relevant laser beam in an underdense plasma. These proton sources also open new opportunities for ion beam generation and control, and could stimulate development of compact ion accelerators for many applications.

  17. Wave optical theory for fast self-focusing of laser beams in plasmas

    International Nuclear Information System (INIS)

    Subbarao, D.; Uma, R.; Ghatak, A.K.; Indian Inst. of Tech., New Delhi. Dept. of Physics)

    1983-01-01

    A theory based on the field and non-linearity expansions in terms of Laguerre-Gauss functions is presented. The theory is useful when very fast self focusing occurs, as in the case of relativistic self focusing. Results for self trapping with a saturable non-linearity are closer to the numerical results than those obtained by any other theory. (author)

  18. Development of sausage-type instability in a Z-pinch plasma column

    International Nuclear Information System (INIS)

    Vikhrev, V.V.; Ivanov, V.V.; Rozanova, G.A.

    1993-01-01

    The development of sausage-type instabilities in an initially homogeneous Z-pinch plasma column has been investigated by means of numerical modelling. It is shown that in the presence of short-wave perturbations of a Z-pinch boundary and a rarefied plasma surrounding the pinch, cavities filled with a rarefied plasma and with a magnetic field are formed in the plasma column. As a result of this cavity growth, small columns of dense plasma form on the axis in the Z-pinch which have a temperature substantially higher than the average plasma temperature in the plasma column. When deuterium is present in the pinch, these dense high temperature bunches can become a source of intensive neutron radiation. (author). 24 refs, 7 figs

  19. Plasma-liquid system with reverse vortex flow of 'tornado' type (TORNADO-LE)

    International Nuclear Information System (INIS)

    Nedybalyuk, O.A.; Chernyak, V.Ya.; Olszewski, S.V.

    2010-01-01

    The results of experimental investigations of the plasma in plasma-liquid system with reverse vortex flow of 'tornado' type are presented. Volt-ampere characteristic of discharge in the current range from 200 to 400 mA were measured. Emission spectra of plasma in range from 200 to 1100 nm were measured. Excitation temperatures (electronic T e * , vibrational T v * and rotational T r * ) were obtained. Emission spectra of hydroxyl OH were calculated.

  20. Total plasma homocysteine is associated with hypertension in Type I diabetic patients

    DEFF Research Database (Denmark)

    Neugebauer, S; Tarnow, L; Stehouwer, C D

    2002-01-01

    between plasma homocysteine concentrations, methylenetetrahydrofolate reductase gene polymorphism, hypertension, diabetic microvascular and macrovascular complications associated with kidney function. METHODS: Vascular complications, hypertension, methylenetetrahydrofolate reductase genotype (RFLP...... was an independent determinant of plasma homocysteine, the methylenetetrahydrofolate reductase gene polymorphism was neither associated with diabetic vascular complications nor with hypertension. CONCLUSION/INTERPRETATION: Increased plasma homocysteine concentrations but not the T allele per se, enhance the risk...... of hypertension and of CHD in Danish Type I diabetic patients with normal renal function....

  1. Parathyroid mitogenic activity in plasma from patients with familial multiple endocrine neoplasia type 1

    International Nuclear Information System (INIS)

    Brandi, M.L.; Aurbach, G.D.; Fitzpatrick, L.A.; Quarto, R.; Spiegel, A.M.; Bliziotes, M.M.; Norton, J.A.; Doppman, J.L.; Marx, S.J.

    1986-01-01

    Hyperplasia of the parathyroid glands is a central feature of familial multiple endocrine neoplasia type 1. We used cultured bovine parathyroid cells to test for mitogenic activity in plasma from patients with this disorder. Normal plasma stimulated [ 3 H]thymidine incorporation, on the average, to the same extent as it was stimulated in a plasma-free control culture. This contrasted with the results of the tests with plasma from patients with familial multiple endocrine neoplasia type 1, in which parathyroid mitogenic activity increased 2400 percent over the control value (P less than 0.001). Plasma from these patients also stimulated the proliferation of bovine parathyroid cells in culture, whereas plasma from normal subjects inhibited it. Parathyroid mitogenic activity in plasma from the patients with familial multiple endocrine neoplasia type 1 was greater than that in plasma from patients with various other disorders, including sporadic primary hyperparathyroidism (with adenoma, hyperplasia, or cancer of the parathyroid), sporadic primary hypergastrinemia, sporadic pituitary tumor, familial hypocalciuric hypercalcemia, and multiple endocrine neoplasia type 2 (P less than 0.05). Parathyroid mitogenic activity in the plasma of patients with familial multiple endocrine neoplasia type 1 persisted for up to four years after total parathyroidectomy. The plasma also had far more mitogenic activity in cultures of parathyroid cells than did optimal concentrations of known growth factors or of any parathyroid secretagogue. This mitogenic activity had an apparent molecular weight of 50,000 to 55,000. We conclude that primary hyperparathyroidism in familial multiple endocrine neoplasia type 1 may have a humoral cause

  2. Use of DPP-4 inhibitors in type 2 diabetes: focus on sitagliptin

    Directory of Open Access Journals (Sweden)

    Bo Ahrén

    2010-03-01

    Full Text Available Bo AhrénDepartment of Clinical Sciences, Lund University, Lund, SwedenAbstract: Inhibition of dipeptidyl peptidase-4 (DPP-4 prevents the inactivation of glucagonlike peptide-1 (GLP-1. This increases circulating levels of active GLP-1, stimulates insulin secretion and inhibits glucagon secretion, which results in lowering of glucose levels and improvement of the glycemic control in patients with type 2 diabetes. This review summarizes experiences with DPP-4 inhibition in the treatment of type 2 diabetes, with a focus on sitagliptin. Sitagliptin has in several clinical studies been shown to improve metabolic control in type 2 diabetes, both when used as monotherapy and when used in combination with metformin, sulfonylurea, thiazolidinediones or insulin. The reduction in HbA1c is ≈0.6% to 1.0% from baseline levels of 7.5% to 8.7% over 6 to 12 months therapy. Sitagliptin has a favorable safety profile, is highly tolerable, and there is a minimal risk of hypoglycemia. Furthermore, sitagliptin is body weight neutral or induces a slight body weight reduction. Sitagliptin may be used in the early stages of type 2 diabetes in combination with metformin or other treatments in subjects with inadequate glycemic control on these treatments alone. Sitagliptin may also be used in monotherapy and, finally, sitagliptin may be used in combination with insulin in more advanced stages of the disease.Keywords: glucagon-like peptide-1, dipeptidyl peptidase-4, type 2 diabetes, sitagliptin, treatment

  3. Bounds imposed on the sheath velocity of a dense plasma focus by conservation laws and ionization stability condition

    International Nuclear Information System (INIS)

    Auluck, S. K. H.

    2014-01-01

    Experimental data compiled over five decades of dense plasma focus research are consistent with the snowplow model of sheath propagation, based on the hypothetical balance between magnetic pressure driving the plasma into neutral gas ahead and “wind pressure” resisting its motion. The resulting sheath velocity, or the numerically proportional “drive parameter,” is known to be approximately constant for devices optimized for neutron production over 8 decades of capacitor bank energy. This paper shows that the validity of the snowplow hypothesis, with some correction, as well as the non-dependence of sheath velocity on device parameters, have their roots in local conservation laws for mass, momentum, and energy coupled with the ionization stability condition. Both upper and lower bounds on sheath velocity are shown to be related to material constants of the working gas and independent of the device geometry and capacitor bank impedance

  4. Bounds imposed on the sheath velocity of a dense plasma focus by conservation laws and ionization stability condition

    Energy Technology Data Exchange (ETDEWEB)

    Auluck, S. K. H., E-mail: skhauluck@gmail.com, E-mail: skauluck@barc.gov.in [Physics Group, Bhabha Atomic Research Center, Mumbai (India)

    2014-09-15

    Experimental data compiled over five decades of dense plasma focus research are consistent with the snowplow model of sheath propagation, based on the hypothetical balance between magnetic pressure driving the plasma into neutral gas ahead and “wind pressure” resisting its motion. The resulting sheath velocity, or the numerically proportional “drive parameter,” is known to be approximately constant for devices optimized for neutron production over 8 decades of capacitor bank energy. This paper shows that the validity of the snowplow hypothesis, with some correction, as well as the non-dependence of sheath velocity on device parameters, have their roots in local conservation laws for mass, momentum, and energy coupled with the ionization stability condition. Both upper and lower bounds on sheath velocity are shown to be related to material constants of the working gas and independent of the device geometry and capacitor bank impedance.

  5. Compressional Pc5 type pulsations in the morningside plasma sheet

    Directory of Open Access Journals (Sweden)

    A. Vaivads

    Full Text Available We study compressional pulsations in Pc5 frequency range observed in the dawn-side at distances of about 10 RE , close to the magnetic equator. We use data obtained during two events of conjunctions between Equator-S and Geotail: 1000–1700 UT on 9 March 1998, and 0200–0600 UT on 25 April 1998. In both events, pulsations are observed after substorm activity. The pulsations are antisymmetric with respect to the equatorial plane (even mode, and move eastward with phase velocity close to plasma velocity. The pulsations tend to be pressure balanced. We also discuss possible generation mechanisms of the pulsations.

    Key words. Magnetospheric physics (magnetospheric configuration and dynamics; MHD waves and instabilities; plasma sheet

  6. Compressional Pc5 type pulsations in the morningside plasma sheet

    Directory of Open Access Journals (Sweden)

    A. Vaivads

    2001-03-01

    Full Text Available We study compressional pulsations in Pc5 frequency range observed in the dawn-side at distances of about 10 RE , close to the magnetic equator. We use data obtained during two events of conjunctions between Equator-S and Geotail: 1000–1700 UT on 9 March 1998, and 0200–0600 UT on 25 April 1998. In both events, pulsations are observed after substorm activity. The pulsations are antisymmetric with respect to the equatorial plane (even mode, and move eastward with phase velocity close to plasma velocity. The pulsations tend to be pressure balanced. We also discuss possible generation mechanisms of the pulsations.Key words. Magnetospheric physics (magnetospheric configuration and dynamics; MHD waves and instabilities; plasma sheet

  7. Dipeptidyl peptidase-4 inhibitors in type 2 diabetes therapy – focus on alogliptin

    Directory of Open Access Journals (Sweden)

    Capuano A

    2013-09-01

    Full Text Available Annalisa Capuano,1 Liberata Sportiello,1 Maria Ida Maiorino,2 Francesco Rossi,1 Dario Giugliano,2 Katherine Esposito3 1Department of Experimental Medicine, 2Department of Medical, Surgical, Neurological, Metabolic Sciences, and Geriatrics, 3Department of Clinical and Experimental Medicine and Surgery, Second University of Naples, Naples, Italy Abstract: Type 2 diabetes mellitus is a complex and progressive disease that is showing an apparently unstoppable increase worldwide. Although there is general agreement on the first-line use of metformin in most patients with type 2 diabetes, the ideal drug sequence after metformin failure is an area of increasing uncertainty. New treatment strategies target pancreatic islet dysfunction, in particular gut-derived incretin hormones. Inhibition of the enzyme dipeptidyl peptidase-4 (DPP-4 slows degradation of endogenous glucagon-like peptide-1 (GLP-1 and thereby enhances and prolongs the action of the endogenous incretin hormones. The five available DPP-4 inhibitors, also known as 'gliptins' (sitagliptin, vildagliptin, saxagliptin, linagliptin, alogliptin, are small molecules used orally with similar overall clinical efficacy and safety profiles in patients with type 2 diabetes. The main differences between the five gliptins on the market include: potency, target selectivity, oral bioavailability, long or short half-life, high or low binding to plasma proteins, metabolism, presence of active or inactive metabolites, excretion routes, dosage adjustment for renal and liver insufficiency, and potential drug–drug interactions. On average, treatment with gliptins is expected to produce a mean glycated hemoglobin (HbA1c decrease of 0.5%–0.8%, with about 40% of diabetic subjects at target for the HbA1c goal <7%. There are very few studies comparing DPP-4 inhibitors. Alogliptin as monotherapy or added to metformin, pioglitazone, glibenclamide, voglibose, or insulin therapy significantly improves glycemic control

  8. On 2D electron cloud dynamics in high-current plasma lens for ion beam focusing

    International Nuclear Information System (INIS)

    Goncharov, A. A.; Litovko, I. V.; Onishchenko, I. N.; Zadorozhny, V. F.

    1997-01-01

    In this paper we are dealing with the appear the stable existence and dynamics of 2-D electron vortical structures in crossed electric and magnetic fields. The collective interactions in which the electron motion is nonlinear and ion motion is linear, is concerned. By using of the kinetic equation and the catastrophe theory approach we deduce an origin of the vortical structures. The nonlinear differential equation for the electric potential in a hydrodynamical approximation is obtained. It describes a drift motion of the electrons in oscillating electric fields of the high-current plasma lens(PL), arising due to presence the principal unremoval radical gradient of the axical component of the magnetic field. It was shown that the considered equations have contained the solutions in the form of the single vortical structures. The stability of the structures are given

  9. Effect of cholecalciferol and levo carnitine on plasma glucose, plasma insulin and insulin resistance in type 2 diabetic rats

    International Nuclear Information System (INIS)

    Anwar, M. K.; Hussain, M. M.; Khan, M. A.; Ahmad, T.

    2013-01-01

    Objective: To compare the effects of combined and individual supplementation of cholecalciferol and levo carnitine on plasma glucose, plasma insulin and insulin resistance in type 2 diabetic rats. Methods: The randomised controlled trial was conducted at the Department of Physiology, Army Medical College, Rawalpindi, between October 2010 and April 2011. It comprised 80 healthy Sprague Dawley rats who were divided into four groups (n = 20 each). Rats were fed high-fat diet for 2 weeks followed by an intraperitoneal injection of streptozocin to induce type 2 diabetes mellitus. Group I served as diabetic control; group II was given cholecalciferol; group III; levo carnitine; and group IV was administered cholecalciferol and levo carnitine together. After 6 days of supplementation, terminal intracardiac blood extraction was done and samples were analysed for fasting plasma glucose and plasma insulin. Insulin resistance was calculated by homeostatic model assessment for insulin resistance. SPSS 17.0 was used for statistical analysis. Results: Fasting plasma glucose levels were significantly decreased (p <0.001) in the combined supplementation group compared to the diabetic control and individual supplementation groups. Combined supplementation showed a significant increase in fasting plasma insulin levels when compared with diabetic control and levo carnitine groups (p <0.001), and the effect of combined supplementation on ameliorating insulin resistance was significantly better (p <0.001) as compared to the individual supplementation of cholecalciferol and levo carnitine. Conclusions: The combined supplementation of cholecalciferol and levo carnitine for 6 days markedly improved the glycaemic control, insulin secretion and insulin resistance in type 2 diabetic rats on high-fat diet. A prolonged supplementation by both the compounds along with caloric restriction may yield a more promising outcome. (author)

  10. Characteristics of the Plasma Source for Ground Ionosphere Simulation Surveyed by Disk-Type Langmuir Probe

    Science.gov (United States)

    Ryu, Kwangsun; Lee, Junchan; Kim, Songoo; Chung, Taejin; Shin, Goo-Hwan; Cha, Wonho; Min, Kyoungwook; Kim, Vitaly P.

    2017-12-01

    A space plasma facility has been operated with a back-diffusion-type plasma source installed in a mid-sized vacuum chamber with a diameter of 1.5 m located in Satellite Technology Research Center (SaTReC), Korea Advanced Institute of Science and Technology (KAIST). To generate plasma with a temperature and density similar to the ionospheric plasma, nickel wires coated with carbonate solution were used as filaments that emit thermal electrons, and the accelerated thermal electrons emitted from the heated wires collide with the neutral gas to form plasma inside the chamber. By using a disk-type Langmuir probe installed inside the vacuum chamber, the generation of plasma similar to the space environment was validated. The characteristics of the plasma according to the grid and plate anode voltages were investigated. The grid voltage of the plasma source is realized as a suitable parameter for manipulating the electron density, while the plate voltage is suitable for adjusting the electron temperature. A simple physical model based on the collision cross-section of electron impact on nitrogen molecule was established to explain the plasma generation mechanism.

  11. Dense plasma focus PACO as a hard X-ray emitter: a study on the radiation source

    OpenAIRE

    Supán, L.; Guichón, S.; Milanese, Maria Magdalena; Niedbalski, Jorge Julio; Moroso, Roberto Luis; Acuña, H.; Malamud, Florencia

    2016-01-01

    The radiation in the X-ray range detected outside the vacuum chamber of the dense plasma focus (DPF) PACO, are produced on the anode zone. The zone of emission is studied in a shot-to-shot analysis, using pure deuterium as filling gas. We present a diagnostic method to determine the place and size of the hard X-ray source by image analysis of high density radiography plates. Fil: Supán, L.. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Insti...

  12. ESTUDIO EXPERIMENTAL DE UNA DESCARGA PLASMA FOCUS RAPIDA OPERADA EN EL RANGO DE DECENAS DE JOULES EMITIENDO NEUTRONES

    OpenAIRE

    TARIFEÑO SALDIVIA; ARIEL ESTEBAN; TARIFEÑO SALDIVIA; ARIEL ESTEBAN

    2011-01-01

    En esta investigación doctoral se estudió experimentalmente una descarga plasma focus operada a decenas de joules y decenas de kiloamperes. El dispositivo genera una descarga coaxial por medio de un arreglo de electrodos los cuales consisten de un electrodo central, un aislante cilíndrico y un electrodo exterior. La descarga es alimentada por un generador capacitivo y se opera a presiones de algunos milibar. Los parámetros eléctricos típicos del dispositivo, denominado PF-50J, son T/4 ...

  13. Soft x-ray measurements in the FN-II dense plasma focus device for different anode configurations

    International Nuclear Information System (INIS)

    Rojo-Blanco, C; Castillo-Mejía, F; Rangel-Gutiérrez, J; Herrera-Velázquez, J J E

    2012-01-01

    A study of the soft x-ray emission is presented, for a low energy (4.8 kJ) dense plasma focus device. Three Quantrad Si PIN-diodes with differential filter combinations of Be, Al, Ti, Ni, and Mo are employed as time-resolved x-ray detectors. The x-ray flux in different energy windows is measured as function of the deuterium filling pressure. A comparison is made for three anode configurations: (a) hollow, (b) flat, and (c) 2mm diameter W needle.

  14. Experimental study of a fast plasma focus discharge operated in the range of tens of joules emitting neutrons

    International Nuclear Information System (INIS)

    Tarifeno Saldivia, Eriel Esteban

    2011-01-01

    In this doctoral research, a small plasma focus discharge operated at tens of joules and kilo amperes has been experimentally studied. This device produces a coaxial discharge by an electrode arrange which consists of an inner electrode, a cylindrical insulator, and an outer electrode. The discharge is driven by a capacitive generator and it is operated at pressures of some millibars. Typical electrical parameters of the device are T/4∼150ns, 160 nF, 40 nH, 30-100J, 40-70kA. When Deuterium is used as filling gas, neutrons are produced by fusion reactions. The device, namely PF-50J, is one of the most extreme plasma focus reported in the literature to emit neutrons. The results of this work have demonstrated that the same dynamics found in larger machines (operated from kJ to MJ) is also found in this extremely low energy device which means that after the discharge is initiated, a plasma sheet is formed over the insulator. By the action of the Lorentz force, the plasma sheet moves axially. When the sheet reaches the top end of the inner electrode, it starts to implode radially to finally form a dense plasma column (pinch). Finally, the plasma column is disrupted 5-10ns after column formation. Shock piston velocities of the order of 10 4 -10 5 m/s were estimated from experiments for each discharge dynamical phase. Typical pinch densities of 10 24-25 m -3 were also observed in PF-50J. An interesting feature observed in this work is the formation of axial jet-like structures which appears at late times almost hundred nanoseconds after pinch disruption. These structures are composed by a metallic plasma which results from ablation of the inner electrode. The mechanism responsible for the formation of this kind of structure is still unknown, although evidence suggests that the phenomena is not related to the pinch formation process. One of the principal motivations of this thesis was to study the optimization for neutron emission in the PF-50J device. This plasma focus

  15. Investigation on Plasma Jet Flow Phenomena During DC Air Arc Motion in Bridge-Type Contacts

    Science.gov (United States)

    Zhai, Guofu; Bo, Kai; Chen, Mo; Zhou, Xue; Qiao, Xinlei

    2016-05-01

    Arc plasma jet flow in the air was investigated under a bridge-type contacts in a DC 270 V resistive circuit. We characterized the arc plasma jet flow appearance at different currents by using high-speed photography, and two polished contacts were used to search for the relationship between roughness and plasma jet flow. Then, to make the nature of arc plasma jet flow phenomena clear, a simplified model based on magnetohydrodynamic (MHD) theory was established and calculated. The simulated DC arc plasma was presented with the temperature distribution and the current density distribution. Furthermore, the calculated arc flow velocity field showed that the circular vortex was an embodiment of the arc plasma jet flow progress. The combined action of volume force and contact surface was the main reason of the arc jet flow. supported by National Natural Science Foundation of China (Nos. 51307030, 51277038)

  16. Effects of relativistic and channel focusing on q-Gaussian laser beam propagating in a preformed parabolic plasma channel

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Li; Hong, Xue-Ren, E-mail: hxr_nwnu@163.com; Sun, Jian-An, E-mail: sunja@nwnu.edu.cn; Tang, Rong-An; Yang, Yang; Zhou, Wei-Jun; Tian, Jian-Min; Duan, Wen-Shan

    2017-07-12

    The propagation of q-Gaussian laser beam in a preformed plasma channel is investigated by means of the variational method. A differential equation for the spot size has been obtained by including the effects of relativistic self-focusing, ponderomotive self-channeling and preformed channel focusing. The propagation behaviors and their corresponding physical conditions are identified. The comparison of the propagation between q-Gaussian and Gaussian laser beams is done by theoretical and numerical analysis. It is shown that, in the same channel, the focusing power of q-Gaussian laser beam is lower than that of Gaussian laser beam, i.e., the q-Gaussian laser beam is easier to focus than Gaussian laser beam. - Highlights: • Some behaviors for Gaussian laser are also found for q-Gaussian one. • The parameter regions corresponding to different laser behaviors are given. • Influence of q on the laser propagation behavior is obvious. • The q-Gaussian laser beam is easier to focus than the Gaussian one.

  17. Effects of relativistic and channel focusing on q-Gaussian laser beam propagating in a preformed parabolic plasma channel

    International Nuclear Information System (INIS)

    Wang, Li; Hong, Xue-Ren; Sun, Jian-An; Tang, Rong-An; Yang, Yang; Zhou, Wei-Jun; Tian, Jian-Min; Duan, Wen-Shan

    2017-01-01

    The propagation of q-Gaussian laser beam in a preformed plasma channel is investigated by means of the variational method. A differential equation for the spot size has been obtained by including the effects of relativistic self-focusing, ponderomotive self-channeling and preformed channel focusing. The propagation behaviors and their corresponding physical conditions are identified. The comparison of the propagation between q-Gaussian and Gaussian laser beams is done by theoretical and numerical analysis. It is shown that, in the same channel, the focusing power of q-Gaussian laser beam is lower than that of Gaussian laser beam, i.e., the q-Gaussian laser beam is easier to focus than Gaussian laser beam. - Highlights: • Some behaviors for Gaussian laser are also found for q-Gaussian one. • The parameter regions corresponding to different laser behaviors are given. • Influence of q on the laser propagation behavior is obvious. • The q-Gaussian laser beam is easier to focus than the Gaussian one.

  18. Compressional Pc5 type pulsations in the morningside plasma sheet

    Energy Technology Data Exchange (ETDEWEB)

    Vaivads, A.; Baumjohann, W.; Haerendel, G.; Nakamura, R.; Kucharek, H.; Klecker, B. [Max-Planck-Institut fuer Extraterrestrische Physik, Garching (Germany); Lessard, M.R. [Dartmouth Coll., Hanover, NH (United States). Thayer School of Engineering; Kistler, L.M. [New Hampshire Univ., Durham (United States). Space Science Center; Mukai, T.; Nishida, A. [Institute of Space and Astronautical Science, Sagamihara, Kanagawa (Japan)

    2001-03-01

    We study compressional pulsations in Pc5 frequency range observed in the dawn-side at distances of about 10 R{sub E}, close to the magnetic equator. We use data obtained during two events of conjunctions between Equator-S and Geotail: 1000-1700 UT on 9 March 1998, and 0200-0600 UT on 25 April 1998. In both events, pulsations are observed after substorm activity. The pulsations are antisymmetric with respect to the equatorial plane (even mode), and move eastward with phase velocity close to plasma velocity. The pulsations tend to be pressure balanced. We also discuss possible generation mechanisms of the pulsations. (orig.)

  19. Axial and radial preliminary results of the neutron radiation from miniature plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, J.; Silva, P.; Soto, L. [Comision Chilena de Energia Nuclear, Santiago (Chile)

    2004-07-01

    As first step of a program to design a repetitive pulsed neutron generator for applications, two miniature plasma foci have been designed and constructed at the Chilean commission of nuclear energy. The devices operate at an energy level of the order of tens of joules (PF-50 J, 160 nF capacitor bank, 20-35 kV, 32-100 J, {approx} 150 ns time to peak current) and hundred of joules (PF-400 J, 880 nF, 20-35 kV, 176-539 J, {approx} 300 ns time to peak current). Neutron emission has been obtained in both devices operating in deuterium. A specific technique was necessary to develop in order to detect neutron pulsed of 10{sup 4} neutrons per shot. The maximum total neutron yield measured was of the order of 10{sup 6} and 10{sup 4} neutrons per shot in the PF-400 J and PF-50 J respectively. Axial and radial measurements of the neutron emission are presented and the anisotropy is evaluated in this work. The neutrons are measured by pairs of silver activation counters, {sup 3}He detectors and scintillator-photomultiplier detectors. (authors)

  20. Heliocentric radial variation of plasma oscillations associated with type III radio bursts

    International Nuclear Information System (INIS)

    Gurnett, D.A.; Anderson, R.R.; Scarf, F.L.; Kurth, W.S.

    1978-01-01

    A survey is presented of all of the electron plasma oscillation events found to date in association with low-frequency type III solar radio bursts using approximately 9 years of observations from the Imp 6 and 8, Helios 1 and 2, and Voyager 1 and 2 spacecraft. Plasma oscillation events associated with type III radio bursts show a pronounced increase in both the intensity and the frequency of occurrence with decreasing heliocentric radial distance. This radial dependence explains why intense electron plasma oscillations are seldom observed in association with type III radio bursts at the orbit of the earth. Possible interpretations of the observed radial variation in the plasma oscillation intensity are considered

  1. Shock and magnetosonic waves in a Mather-type plasma focus

    International Nuclear Information System (INIS)

    Gerdin, G.; Venneri, F.; Boulais, K.

    1986-01-01

    A fast streak camera has been used to measure the speeds of the axially propagating transverse ionization wave (or rundown phase), the radial collapse, and what appears to be a magnetosonic compression wave propagating along the pinch. The current flowing in the moving current sheath was measured by means of a magnetic probe placed between the coaxial electrodes. The magnetic probe is necessary to determine the pinch current since the device current does not always entirely flow in the current sheath (CS). The CS current was varied from about 200 to 800 kA in the experiments reported here at a static fill of 3 Torr of deuterium. All three velocities were found to be linear with the CS current as predicted from simple models with less than a 10% uncertainty in the least squares slope. The axial or rundown speed was found to be consistent with the constant speed model of v/sub AX/ ≅ v/sub A//√2 where v/sub A/ is the Alfven speed at the surface of the inner conductor. The velocity of the radial collapse was compared with a 4th Order Runge-Kutta solution to the snowplow model or 'M' theory and the agreement was not as good. The magnetosonic scaling with current at constant fill pressure is consistent with a constant mass per unit length being swept up by the snowplow and representing about 1/4 of the original fill gas mass per unit length over the center electrode

  2. Review of wet environment types on Mars with focus on duration and volumetric issues.

    Science.gov (United States)

    Kereszturi, Akos

    2012-06-01

    The astrobiological significance of certain environment types on Mars strongly depends on the temperature, duration, and chemistry of liquid water that was present there in the past. Recent works have focused on the identification of signs of ancient water on Mars, as it is more difficult to estimate the above-mentioned parameters. In this paper, two important factors are reviewed, the duration and the volume of water at different environment types on past and present Mars. Using currently available information, we can only roughly estimate these values, but as environment types show characteristic differences in this respect, it is worth comparing them and the result may have importance for research in astrobiology. Impact-induced and geothermal hydrothermal systems, lakes, and valley networks were in existence on Mars over the course of from 10(2) to 10(6) years, although they would have experienced substantially different temperature regimes. Ancient oceans, as well as water in outflow channels and gullies, and at the microscopic scale as interfacial water layers, would have had inherently different times of duration and overall volume: oceans may have endured from 10(4) to 10(6) years, while interfacial water would have had the smallest volume and residence time of liquid phase on Mars. Martian wet environments with longer residence times of liquid water are believed to have existed for that amount of time necessary for life to develop on Earth between the Late Heavy Bombardment and the age of the earliest fossil record. The results of this review show the necessity for more detailed analysis of conditions within geothermal heat-induced systems to reconstruct the conditions during weathering and mineral alteration, as well as to search for signs of reoccurring wet periods in ancient crater lakes.

  3. Plasma and muscle myostatin in relation to type 2 diabetes

    DEFF Research Database (Denmark)

    Brandt, Claus; Nielsen, Anders R; Fischer, Christian P

    2012-01-01

    Myostatin is a secreted growth factor expressed in skeletal muscle tissue, which negatively regulates skeletal muscle mass. Recent animal studies suggest a role for myostatin in insulin resistance. We evaluated the possible metabolic role of myostatin in patients with type 2 diabetes and healthy...

  4. Diagnostics of a stationary MPD-type plasma jet with a HCN laser interferometer

    International Nuclear Information System (INIS)

    Graser, W.; Hoffmann, P.

    1975-01-01

    A HCN laser interferometer of the Ashby-Jephcott type operating at a wavelength of 337 μm was used to measure spatially resolved electron densities in a stationary MPD-type plasma jet with non-LTE behavior. Experiments were performed with and without superimposed magnetic fields up to 0.1 T at the exit of the plasma accelerator. Electron densities were obtained within the limits of 5times10 12 and 10 15 cm -3 with an accuracy better than 10%. Within the axially symmetric expanding plasma of about 15-cm average diameter and 50-cm length the radial resolving power came to less than 1 cm. So this technique has proved to be suitable to fill a gap in the diagnostics of stationary magnetized plasmas in the mean range of electron densities. (auth)

  5. Plasma adrenaline kinetics in type 1 (insulin-dependent) diabetic patients with and without autonomic neuropathy

    DEFF Research Database (Denmark)

    Dejgaard, A; Hilsted, J; Henriksen, Jens Henrik Sahl

    1989-01-01

    Plasma adrenaline kinetics (clearance, extraction across the forearm, initial plasma disappearance rate, mean sojourn time, volume of distribution) were studied in sixteen Type 1 (insulin-dependent) diabetic patients during constant i.v. infusion of tritium labelled adrenaline. In patients with (n...... = 8) and without (n = 8) neuropathy forearm venous plasma noradrenaline and adrenaline concentrations as well as plasma clearance of adrenaline based on arterial sampling (1.7 vs 2.1 l/min) were not significantly different. The initial disappearance time (T 1/2) after the infusion of the tritium...... labelled adrenaline had been stopped was significantly prolonged in Type 1 diabetic patients with neuropathy compared to those without (after 20 min infusion 2.7 vs 2.2 min, p less than 0.02, after 75 min infusion 3.7 vs 2.9 min, p less than 0.05). The corresponding values for the mean sojourn time...

  6. Evaluation of Turner relaxed state as a model of long-lived ion-trapping structures in plasma focus and Z-pinches

    Science.gov (United States)

    Auluck, S. K. H.

    2011-03-01

    Relatively long-lived spheroidal structures coincident with the neutron emission phase have been observed in frozen deuterium fiber Z-pinch and some plasma focus devices. Existence of energetic ion-trapping mechanism in plasma focus has also been inferred from experimental data. It has been conjectured that these are related phenomena. This paper applies Turner's theory [L. Turner, IEEE Trans. Plasma Sci. 14, 849 (1986)] of relaxation of a Hall magnetofluid to construct a model of these structures and ion-trapping mechanism. Turner's solution modified for a finite-length plasma is used to obtain expressions for the magnetic field, velocity, and equilibrium pressure fields and is shown to represent an entity which is simultaneously a fluid vortex, a force-free magnetic field, a confined finite-pressure plasma, a charged object, and a trapped energetic ion beam. Characteristic features expected from diagnostic experiments are evaluated and shown to resemble experimental observations.

  7. Separated Type Atmospheric Pressure Plasma Microjets Array for Maskless Microscale Etching

    Directory of Open Access Journals (Sweden)

    Yichuan Dai

    2017-06-01

    Full Text Available Maskless etching approaches such as microdischarges and atmospheric pressure plasma jets (APPJs have been studied recently. Nonetheless, a simple, long lifetime, and efficient maskless etching method is still a challenge. In this work, a separated type maskless etching system based on atmospheric pressure He/O2 plasma jet and microfabricated Micro Electro Mechanical Systems (MEMS nozzle have been developed with advantages of simple-structure, flexibility, and parallel processing capacity. The plasma was generated in the glass tube, forming the micron level plasma jet between the nozzle and the surface of polymer. The plasma microjet was capable of removing photoresist without masks since it contains oxygen reactive species verified by spectra measurement. The experimental results illustrated that different features of microholes etched by plasma microjet could be achieved by controlling the distance between the nozzle and the substrate, additive oxygen ratio, and etch time, the result of which is consistent with the analysis result of plasma spectra. In addition, a parallel etching process was also realized by plasma microjets array.

  8. Isotopic ratio measurement using a double focusing magnetic sector mass analyser with an inductively coupled plasma as an ion source

    International Nuclear Information System (INIS)

    Walder, A.J.; Freedman, P.A.

    1992-01-01

    An inductively coupled plasma source was coupled to a magnetic sector mass analyser equipped with seven Faraday detectors. An electrostatic filter located between the plasma source and the magnetic sector was used to create a double focusing system. Isotopic ratio measurements of uranium and lead standards revealed levels of internal and external precision comparable to those obtained using thermal inonization mass spectrometry. An external precision of 0.014% was obtained from the 235 U: 238 U measurement of six samples of a National Bureau of Standards (NBS) Standard Reference Material (SRM) U-500, while an RSD of 0.022% was obtained from the 206 Pb: 204 Pb measurement of six samples of NBS SRM Pb-981. Measured isotopic ratios deviated from the NBS value by approximately 0.9% per atomic mass unit. This deviation approximates to a linear function of mass bias and can therefore be corrected for by the analysis of standards. The analysis of NBS SRM Sr-987 revealed superior levels of internal and external precision. The normalization of the 87 Sr: 86 Sr ratio to the 86 Sr: 88 Sr ratio reduced the RSD to approximately 0.008%. The measured ratio was within 0.01% of the NBS value and the day-to-day reproducibility was consistent within one standard deviation. (author)

  9. Fixation of the stressed state of glass plates by coating them with thin films using a plasma focus installation

    Science.gov (United States)

    Kolokoltsev, V. N.; Degtiarev, V. F.; Borovitskaya, I. V.; Nikulin, V. Ya.; Peregudova, E. N.; Silin, P. V.; Eriskin, A. A.

    2018-01-01

    Elastic deformation in transparent mediums is usually studied by the photoelasticity method. For opaque mediums the method of film coating and strain gauge method are used. After the external load was removed, the interference pattern corresponding to elastic deformation of the material disappears. It is found that the elastic deformation state of the thin glass plate under the action of concentrated load can be fixed during the deposition of a thin metal film. Deposition of thin copper films was carried out by passing of plasma through the copper tube installed inside the Plasma Focus installation. After removing of the load, interference pattern on the glass plates was observed in the form of Newton’s rings and isogers in non-monochromatic light on the CCD scanners which uses uorescent lamps with cold cathode. It is supposed that the copper film fixes the relief of the surface of the glass plate at the time of deformation and saves it when the load is removed. In the case of a concentrated load, this relief has the shape of a thin lens of large radius. For this reason, the interference of coherent light rays in a thin air gap between the glass of the scanners atbed and the lens surface has the shape of Newton's rings. In this case, when scanning the back side of the plate, isogyres are observed. The presented method can be used in the analysis of the mechanical stress in a various optical elements.

  10. Specific features of X-ray generation by plasma focus chambers with deuterium and deuterium–tritium fillings

    Energy Technology Data Exchange (ETDEWEB)

    Dulatov, A. K., E-mail: bogolubov@vniia.ru; Krapiva, P. S.; Lemeshko, B. D.; Mikhailov, Yu. V.; Moskalenko, I. N.; Prokuratov, I. A.; Selifanov, A. N. [All-Russia Research Institute of Automatics (Russian Federation)

    2016-01-15

    The process of hard X-ray (HXR) generation in plasma focus (PF) chambers was studied experimentally. The radiation was recorded using scintillation detectors with a high time resolution and thermoluminescent detectors in combination with the method of absorbing filters. Time-resolved analysis of the processes of neutron and X-ray generation in PFs is performed. The spectra of HXR emission from PF chambers with deuterium and deuterium–tritium fillings are determined. In experiments with PF chambers filled with a deuterium–tritium mixture, in addition to the HXR pulse with photon energies of up to 200–300 keV, a γ-ray pulse with photon energies of up to 2.5–3.0 MeV is recorded, and a mechanism of its generation is proposed.

  11. Coating of Titanium Nitride on Stainless Steel Targets by a 4 kJ Plasma Focus Device

    Science.gov (United States)

    Omrani, M.; Habibi, M.; Amrollahi, R.

    2012-08-01

    Titanium nitride thin films were deposited on stainless steel (SS316L) targets by using a 4 kJ plasma focus device. The corresponding energy flux delivered to SS316L surface is estimated to be 2.69 × 1013 kev cm-3 ns-1. X-ray diffraction analysis reveals the formation of a nanocrystalline titanium nitride coating on the surface of targets. Thickness of the elements found on the surface of treated samples which are obtained by Rutherford backscattering spectrometry analysis (RBS) were (×1015 at/cm2) .45% Ti, 50% N and 5% Fe. Scanning electron microscopy was used to indicate changes in surface morphology. Existence of grains in different size confirms the formation of TiN crystals on the surface of targets.

  12. Research on anisotropy of fusion-produced protons and neutrons emission from high-current plasma-focus discharges

    Energy Technology Data Exchange (ETDEWEB)

    Malinowski, K., E-mail: karol.malinowski@ncbj.gov.pl; Sadowski, M. J.; Szydlowski, A. [National Centre for Nuclear Research (NCBJ), 05-400 Otwock (Poland); Institute of Plasma Physics and Laser Microfusion (IFPiLM), 01-497 Warsaw (Poland); Skladnik-Sadowska, E.; Czaus, K.; Kwiatkowski, R.; Zaloga, D. [National Centre for Nuclear Research (NCBJ), 05-400 Otwock (Poland); Paduch, M.; Zielinska, E. [Institute of Plasma Physics and Laser Microfusion (IFPiLM), 01-497 Warsaw (Poland)

    2015-01-15

    The paper concerns fast protons and neutrons from D-D fusion reactions in a Plasma-Focus-1000U facility. Measurements were performed with nuclear-track detectors arranged in “sandwiches” of an Al-foil and two PM-355 detectors separated by a polyethylene-plate. The Al-foil eliminated all primary deuterons, but was penetrable for fast fusion protons. The foil and first PM-355 detector were penetrable for fast neutrons, which were converted into recoil-protons in the polyethylene and recorded in the second PM-355 detector. The “sandwiches” were irradiated by discharges of comparable neutron-yields. Analyses of etched tracks and computer simulations of the fusion-products behavior in the detectors were performed.

  13. Dense Plasma Focus: physics and applications (radiation material science, single-shot disclosure of hidden illegal objects, radiation biology and medicine, etc.)

    International Nuclear Information System (INIS)

    Gribkov, V A; Miklaszewski, R; Paduch, M; Zielinska, E; Chernyshova, M; Pisarczyk, T; Sadowski, M J; Pimenov, V N; Demina, E V; Niemela, J; Crespo, M-L; Cicuttin, A; Tomaszewski, K; Skladnik-Sadowska, E; Pytel, K; Zawadka, A; Giannini, G; Longo, F; Talab, A; Ul'yanenko, S E

    2015-01-01

    The paper presents some outcomes obtained during the year of 2013 of the activity in the frame of the International Atomic Energy Agency Co-ordinated research project 'Investigations of Materials under High Repetition and Intense Fusion-Relevant Pulses'. The main results are related to the effects created at the interaction of powerful pulses of different types of radiation (soft and hard X-rays, hot plasma and fast ion streams, neutrons, etc. generated in Dense Plasma Focus (DPF) facilities) with various materials including those that are counted as perspective ones for their use in future thermonuclear reactors. Besides we discuss phenomena observed at the irradiation of biological test objects. We examine possible applications of nanosecond powerful pulses of neutrons to the aims of nuclear medicine and for disclosure of hidden illegal objects. Special attention is devoted to discussions of a possibility to create extremely large and enormously diminutive DPF devices and probabilities of their use in energetics, medicine and modern electronics. (paper)

  14. Using Focus Group Interviews to Analyze the Behavior of Users of New Types of Tobacco Products

    Science.gov (United States)

    2017-01-01

    Objectives To characterize the usage patterns of new types of tobacco products (NTTPs) to develop effective strategies for the regulation of NTTPs in Korea. Methods We conducted focus group interviews to identify the NTTP usage patterns of research subjects. The NTTPs were limited to electronic cigarettes (e-cigarettes), waterpipe tobacco, and rolling tobacco. We categorized 30 research subjects into 4 groups. The e-cigarette group was divided into adult and adolescent groups. Each group contained 7-8 subjects. An interview lasting approximately 2 hours was conducted with each group. Results Ninety percent of NTTP users used an NTTP in combination with conventional cigarettes. Subjects mostly bought NTTPs online, unlike how they bought cigarettes. Additionally, a great deal of information, such as how to use NTTPs and descriptions of NTTP products, was exchanged through online or offline societies. The primary reason why the subjects used NTTPs was that NTTPs offer a greater range of flavors and aromas than cigarettes. Moreover, NTTPs were felt to be less repulsive than cigarettes. NTTPs were not used as a cigarette substitute; rather, they were mostly used in places and situations where traditional cigarette smoking was not allowed. Conclusions Based on the results of this study, the government should conduct studies on the effects of the combined use of NTTPs and cigarettes on the human body, obtain and provide accurate data regarding NTTP use, and develop and implement polices to ban NTTP advertising, which may arouse adolescents’ curiosity, and the addition of flavoring substances to tobacco products. PMID:29020756

  15. Using Focus Group Interviews to Analyze the Behavior of Users of New Types of Tobacco Products.

    Science.gov (United States)

    Kim, Jinyoung; Lee, Sungkyu

    2017-09-01

    To characterize the usage patterns of new types of tobacco products (NTTPs) to develop effective strategies for the regulation of NTTPs in Korea. We conducted focus group interviews to identify the NTTP usage patterns of research subjects. The NTTPs were limited to electronic cigarettes (e-cigarettes), waterpipe tobacco, and rolling tobacco. We categorized 30 research subjects into 4 groups. The e-cigarette group was divided into adult and adolescent groups. Each group contained 7-8 subjects. An interview lasting approximately 2 hours was conducted with each group. Ninety percent of NTTP users used an NTTP in combination with conventional cigarettes. Subjects mostly bought NTTPs online, unlike how they bought cigarettes. Additionally, a great deal of information, such as how to use NTTPs and descriptions of NTTP products, was exchanged through online or offline societies. The primary reason why the subjects used NTTPs was that NTTPs offer a greater range of flavors and aromas than cigarettes. Moreover, NTTPs were felt to be less repulsive than cigarettes. NTTPs were not used as a cigarette substitute; rather, they were mostly used in places and situations where traditional cigarette smoking was not allowed. Based on the results of this study, the government should conduct studies on the effects of the combined use of NTTPs and cigarettes on the human body, obtain and provide accurate data regarding NTTP use, and develop and implement polices to ban NTTP advertising, which may arouse adolescents' curiosity, and the addition of flavoring substances to tobacco products.

  16. [Medicinal chemistry and pharmacology focused on cannabidiol, a major component of the fiber-type cannabis].

    Science.gov (United States)

    Takeda, Shuso

    2013-01-01

    Considerable attention has focused on cannabidiol (CBD), a major non-psychotropic constituent of fiber-type cannabis plant, and it has been reported to possess diverse biological activities. Although CBD is obtained from non-enzymatic decarboxylation of its parent molecule, cannabidiolic acid (CBDA), several studies have investigated whether CBDA itself is biologically active. In the present report, the author summarizes findings indicating that; 1) CBDA is a selective cyclooxygenase-2 (COX-2) inhibitor, and ii) CBDA possesses an anti-migrative potential for highly invasive cancer cells, apparently through a mechanism involving inhibition of cAMP-dependent protein kinase A, coupled with an activation of the small GTPase, RhoA. Further, the author introduces recent findings on the medicinal chemistry and pharmacology of the CBD derivative, CBD-2',6'-dimethyl ether (CBDD), that exhibits inhibitory activity toward 15-lipoxygenase (15-LOX), an enzyme responsible for the production of oxidized low-density lipoprotein (LDL). These studies establish CBD as both an important experimental tool and as a lead compound for pharmaceutical development. In this review, the author further discusses the potential uses of CBD and its derivatives in future medicines.

  17. Parallel vigilance: parents' dual focus following diagnosis of Type 1 diabetes mellitus in their young child.

    Science.gov (United States)

    Niedel, Selaine; Traynor, Michael; McKee, Martin; Grey, Margaret

    2013-05-01

    There is consensus that enabling patient self-care and expertise leads to better management of chronic illness. Clinicians are being encouraged to manage clinical encounters in ways that promote these outcomes rather than perpetuate hierarchical relationships. This article describes one part of a larger study of 55 outpatient consultations conducted within 14 months of the diagnosis of Type 1 diabetes mellitus in young children. Participants were parents and the specialist doctors, nurses, dieticians and social workers who oversee the child's secondary care. Consultations were audio-recorded and transcribed. Our analysis draws on aspects of conversation analysis (CA) to investigate how parents' talk enacts a growing confidence in the management of their child's disease in the face of questioning from professionals. Analysis reveals how this talk distinguishes a duality of focus that combines the normal watchfulness exhibited by all parents as they protect their children, with an additional intense, parallel watchfulness for signs of potentially serious manifestations of diabetes. We term this phenomenon parallel vigilance and illustrate its development using five representative extracts from consultations. The concept of parallel vigilance extends the chronic illness literature and informs our understanding of a process that contributes to parents' developing expertise and provides new and important insights into the way in which parents conceptualize and implement their evolving role in the care of their child. Moreover, parallel vigilance serves as an enabler of parental contributions to the specialist consultation.

  18. Comparing transfusion reaction rates for various plasma types: a systematic review and meta-analysis/regression.

    Science.gov (United States)

    Saadah, Nicholas H; van Hout, Fabienne M A; Schipperus, Martin R; le Cessie, Saskia; Middelburg, Rutger A; Wiersum-Osselton, Johanna C; van der Bom, Johanna G

    2017-09-01

    We estimated rates for common plasma-associated transfusion reactions and compared reported rates for various plasma types. We performed a systematic review and meta-analysis of peer-reviewed articles that reported plasma transfusion reaction rates. Random-effects pooled rates were calculated and compared between plasma types. Meta-regression was used to compare various plasma types with regard to their reported plasma transfusion reaction rates. Forty-eight studies reported transfusion reaction rates for fresh-frozen plasma (FFP; mixed-sex and male-only), amotosalen INTERCEPT FFP, methylene blue-treated FFP, and solvent/detergent-treated pooled plasma. Random-effects pooled average rates for FFP were: allergic reactions, 92/10 5 units transfused (95% confidence interval [CI], 46-184/10 5 units transfused); febrile nonhemolytic transfusion reactions (FNHTRs), 12/10 5 units transfused (95% CI, 7-22/10 5 units transfused); transfusion-associated circulatory overload (TACO), 6/10 5 units transfused (95% CI, 1-30/10 5 units transfused); transfusion-related acute lung injury (TRALI), 1.8/10 5 units transfused (95% CI, 1.2-2.7/10 5 units transfused); and anaphylactic reactions, 0.8/10 5 units transfused (95% CI, 0-45.7/10 5 units transfused). Risk differences between plasma types were not significant for allergic reactions, TACO, or anaphylactic reactions. Methylene blue-treated FFP led to fewer FNHTRs than FFP (risk difference = -15.3 FNHTRs/10 5 units transfused; 95% CI, -24.7 to -7.1 reactions/10 5 units transfused); and male-only FFP led to fewer cases of TRALI than mixed-sex FFP (risk difference = -0.74 TRALI/10 5 units transfused; 95% CI, -2.42 to -0.42 injuries/10 5 units transfused). Meta-regression demonstrates that the rate of FNHTRs is lower for methylene blue-treated compared with FFP, and the rate of TRALI is lower for male-only than for mixed-sex FFP; whereas no significant differences are observed between plasma types for allergic reactions, TACO

  19. Exploring types of focused factories in hospital care: a multiple case study.

    NARCIS (Netherlands)

    Bredenhoff, E.; Bredenhoff, Eelco; van Lent, W.A.M.; van Harten, Willem H.

    2010-01-01

    Background: Focusing on specific treatments or diseases is proposed as a way to increase the efficiency of hospital care. The definition of "focus" or "focused factory", however, lacks clarity. Examples in health care literature relate to very different organizations. Our aim was to explore the

  20. Changes of plasma angiogenic factors during chronic resistance exercise in type 1 diabetic rats

    International Nuclear Information System (INIS)

    Esfahani, S.P.; Gharakhanlou, R.

    2012-01-01

    Objective: Exercise has several beneficial effects on cardiovascular system. However, the exact mechanism is unclear. The purpose of this study was to evaluate the effects of chronic resistance exercise on some plasma angiogenic factors in type 1 diabetic rats. Methodology: Thirty male Wistar rats were divided into three groups of control, diabetic and diabetic trained (n = 10 each). Diabetes was induced by a single intraperitoneal injection of streptozotocin (55 mg/kg). The rats in the trained group undertook one training session per day, 3 days/week, for 4 weeks. Blood samples were taken and the concentrations of plasma glucose, lipid profile, nitric oxide (NO), vascular endothelial growth factor (VEGF) and soluble form of VEGF receptor-1 (sFlt-1) were determined. Results: We found a significant reduction in plasma NO concentrations in diabetic rats compared to the controls (p 0.05). There were no significant differences in plasma VEGF and sFlt-1 concentrations between diabetic sedentary and trained groups (p > 0.05). Moreover, VEGF/sFlt-1 ratios in diabetic animals were lower than the control group and resistance exercise could not increase this ratio in diabetic animals (p > 0.05) Conclusion: Resistance exercise could not change plasma VEGF, sFlt-1 and VEGF/sFlt-1 ratio. However, it increased plasma NO concentrations in diabetic animals. More studies are needed to determine the effects of this type of exercise on the angiogenesis process. (author)

  1. A Comprehensive Approach Towards Optimizing the Xenon Plasma Focused Ion Beam Instrument for Semiconductor Failure Analysis Applications.

    Science.gov (United States)

    Subramaniam, Srinivas; Huening, Jennifer; Richards, John; Johnson, Kevin

    2017-08-01

    The xenon plasma focused ion beam instrument (PFIB), holds significant promise in expanding the applications of focused ion beams in new technology thrust areas. In this paper, we have explored the operational characteristics of a Tescan FERA3 XMH PFIB instrument with the aim of meeting current and future challenges in the semiconductor industry. A two part approach, with the first part aimed at optimizing the ion column and the second optimizing specimen preparation, has been undertaken. Detailed studies characterizing the ion column, optimizing for high-current/high mill rate activities, have been described to support a better understanding of the PFIB. In addition, a novel single-crystal sacrificial mask method has been developed and implemented for use in the PFIB. Using this combined approach, we have achieved high-quality images with minimal artifacts, while retaining the shorter throughput times of the PFIB. Although the work presented in this paper has been performed on a specific instrument, the authors hope that these studies will provide general insight to direct further improvement of PFIB design and applications.

  2. Plasma adiponectin concentrations are associated with dietary glycemic index in Malaysian patients with type 2 diabetes.

    Science.gov (United States)

    Loh, Beng-In; Sathyasuryan, Daniel Robert; Mohamed, Hamid Jan Jan

    2013-01-01

    Adiponectin, an adipocyte-derived hormone has been implicated in the control of blood glucose and chronic inflammation in type 2 diabetes. However, limited studies have evaluated dietary factors on plasma adiponectin levels, especially among type 2 diabetic patients in Malaysia. The aim of this study was to investigate the influence of dietary glycemic index on plasma adiponectin concentrations in patients with type 2 diabetes. A cross-sectional study was conducted in 305 type 2 diabetic patients aged 19-75 years from the Penang General Hospital, Malaysia. Socio-demographic information was collected using a standard questionnaire while dietary details were determined by using a pre-validated semi-quantitative food frequency questionnaire. Anthropometry measurement included weight, height, BMI and waist circumference. Plasma adiponectin concentrations were measured using a commercial ELISA kit. Data were analyzed using multiple linear regression. After multivariate adjustment, dietary glycemic index was inversely associated with plasma adiponectin concentrations (β =-0.272, 95% CI -0.262, - 0.094; pfoods containing high dietary glycemic index that plasma adiponectin level reduced by 0.3 μg/mL. Thirty two percent (31.9%) of the variation in adiponectin concentrations was explained by age, sex, race, smoking status, BMI, waist circumference, HDL-C, triglycerides, magnesium, fiber and dietary glycemic index according to the multiple linear regression model (R2=0.319). These results support the hypothesis that dietary glycemic index influences plasma adiponectin concentrations in patients with type 2 diabetes. Controlled clinical trials are required to confirm our findings and to elucidate the underlying mechanism.

  3. Dense Plasma Focus Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hui [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Li, Shengtai [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jungman, Gerard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hayes-Sterbenz, Anna Catherine [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-10

    Here we report on high-fidelity 2D and 3D numerical magnetohydrodynamic (MHD) simulations using the LA-COMPASS code to study the pinch formation dynamics in a DPF and the associated instabilities and neutron production.

  4. Using Focus Group Interviews to Analyze the Behavior of Users of New Types of Tobacco Products

    Directory of Open Access Journals (Sweden)

    Jinyoung Kim

    2017-09-01

    Full Text Available Objectives To characterize the usage patterns of new types of tobacco products (NTTPs to develop effective strategies for the regulation of NTTPs in Korea. Methods We conducted focus group interviews to identify the NTTP usage patterns of research subjects. The NTTPs were limited to electronic cigarettes (e-cigarettes, waterpipe tobacco, and rolling tobacco. We categorized 30 research subjects into 4 groups. The e-cigarette group was divided into adult and adolescent groups. Each group contained 7-8 subjects. An interview lasting approximately 2 hours was conducted with each group. Results Ninety percent of NTTP users used an NTTP in combination with conventional cigarettes. Subjects mostly bought NTTPs online, unlike how they bought cigarettes. Additionally, a great deal of information, such as how to use NTTPs and descriptions of NTTP products, was exchanged through online or offline societies. The primary reason why the subjects used NTTPs was that NTTPs offer a greater range of flavors and aromas than cigarettes. Moreover, NTTPs were felt to be less repulsive than cigarettes. NTTPs were not used as a cigarette substitute; rather, they were mostly used in places and situations where traditional cigarette smoking was not allowed. Conclusions Based on the results of this study, the government should conduct studies on the effects of the combined use of NTTPs and cigarettes on the human body, obtain and provide accurate data regarding NTTP use, and develop and implement polices to ban NTTP advertising, which may arouse adolescents’ curiosity, and the addition of flavoring substances to tobacco products.

  5. At wavelength focusing properties evaluation of the Wolter type grazing incidence mirror

    CERN Document Server

    Takeuchi, A; Uesugi, K; Aoki, S

    2001-01-01

    Focusing properties of a Wolter mirror were evaluated in a hard X-ray region (approx 10 keV). Although the sagittal focal spot size was found to be 0.7 mu m, some spots are spread in meridional direction within a range of over 100 mu m. A Foucault-test method has been employed for closer investigation of the focusing properties. Wave-front of the sagittal focusing rays was almost ideal. On the contrary, it was found that slope error of about 100-300 mu rad existed for the meridional focusing.

  6. Application of a Bonner sphere spectrometer for determination of the energy spectra of neutrons generated by ≈1 MJ plasma focus

    Czech Academy of Sciences Publication Activity Database

    Králík, M.; Krása, Josef; Velyhan, Andriy; Scholz, M.; Ivanova-Stanik, I.M.; Bienkowska, B.; Miklaszewski, R.; Schmidt, H.; Řezáč, K.; Klír, D.; Kravárik, J.; Kubeš, P.

    2010-01-01

    Roč. 81, č. 11 (2010), 113503/1-113503/5 ISSN 0034-6748 R&D Projects: GA MŠk LA08024 Grant - others:FP-6 EU(XE) RITA-CT2006-26095 Institutional research plan: CEZ:AV0Z10100523 Keywords : plasma focus * fusion DD neutrons * Bonner sphere spectrometer * energy spectra of scattered neutrons * unfolded and calculated spectra Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.598, year: 2010

  7. Plasma chitotriosidase and CCL18: Early biochemical surrogate markers in type B Niemann-Pick disease

    NARCIS (Netherlands)

    Brinkman, J.; Wijburg, F. A.; Hollak, C. E.; Groener, J. E.; Verhoek, M.; Scheij, S.; Aten, J.; Boot, R. G.; Aerts, J. M.

    2005-01-01

    Type B Niemann-Pick disease (NPD) is a nonneuronopathic lysosomal storage disorder which is characterized by accumulation of sphingomyelin-laden macrophages. The availability of plasma markers for storage cells may be of great value in facilitating therapeutic decisions. Given the similarity of the

  8. Rapid changes in plasma androgens during insulin withdrawal in male type 1 (insulin-dependent) diabetics

    DEFF Research Database (Denmark)

    Madsbad, S; Gluud, C; Bennett, Patrick

    1986-01-01

    Plasma concentrations of testosterone, androstenedione and dihydrotestosterone were measured in 15 Type 1 (insulin-dependent) diabetics with (n = 8) and without (n = 7) B-cell function during 12 h of insulin withdrawal and compared with those of 8 normal subjects. Before insulin withdrawal no sig...

  9. Soluble urokinase-type plasminogen activator receptor forms in plasma as markers of atherosclerotic plaque vulnerability

    DEFF Research Database (Denmark)

    Olson, Fredrik J; Thurison, Tine; Ryndel, Mikael

    2009-01-01

    OBJECTIVES:: To test if circulating forms of the soluble urokinase-type plasminogen activator receptor (suPAR) are potential biomarkers of plaque vulnerability. DESIGN AND METHODS:: Plasma concentrations of suPAR(I-III), suPAR(II-III) and uPAR(I) were measured by time-resolved fluorescence immuno...

  10. Propulsion and Power Generation Capabilities of a Dense Plasma Focus (DPF) Fusion System for Future Military Aerospace Vehicles

    International Nuclear Information System (INIS)

    Knecht, Sean D.; Mead, Franklin B.; Thomas, Robert E.; Miley, George H.; Froning, David

    2006-01-01

    The objective of this study was to perform a parametric evaluation of the performance and interface characteristics of a dense plasma focus (DPF) fusion system in support of a USAF advanced military aerospace vehicle concept study. This vehicle is an aerospace plane that combines clean 'aneutronic' dense plasma focus (DPF) fusion power and propulsion technology, with advanced 'lifting body'-like airframe configurations utilizing air-breathing MHD propulsion and power technology within a reusable single-stage-to-orbit (SSTO) vehicle. The applied approach was to evaluate the fusion system details (geometry, power, T/W, system mass, etc.) of a baseline p-11B DPF propulsion device with Q = 3.0 and thruster efficiency, ηprop = 90% for a range of thrust, Isp and capacitor specific energy values. The baseline details were then kept constant and the values of Q and ηprop were varied to evaluate excess power generation for communication systems, pulsed-train plasmoid weapons, ultrahigh-power lasers, and gravity devices. Thrust values were varied between 100 kN and 1,000 kN with Isp of 1,500 s and 2,000 s, while capacitor specific energy was varied from 1 - 15 kJ/kg. Q was varied from 3.0 to 6.0, resulting in gigawatts of excess power. Thruster efficiency was varied from 0.9 to 1.0, resulting in hundreds of megawatts of excess power. Resulting system masses were on the order of 10's to 100's of metric tons with thrust-to-weight ratios ranging from 2.1 to 44.1, depending on capacitor specific energy. Such a high thrust/high Isp system with a high power generation capability would allow military versatility in sub-orbital space, as early as 2025, and beyond as early as 2050. This paper presents the results that coincide with a total system mass between 15 and 20 metric tons

  11. Characteristics of two types of beam plasma discharge in a laboratory experiment

    International Nuclear Information System (INIS)

    Boswell, R.W.; Kellogg, P.J.

    1983-01-01

    Experiments on the Beam Plasma Discharge (BPD) using an electron beam travelling along a magnetic field have been carried out in a large volume laboratory vacuum chamber. Two different types of BPD have been observed, and scaling laws for varying neutral gas pressure, axial magnetic field, interaction length and electron flux, deduced. The second type of BPD occurs when the beam current is increased well above the threshold for the first type. The transition from the first type to the second, like the ignition of the first, is distinguished by abrupt changes of luminosity, discharge diameter, and wave emission signature

  12. Liver/kidney microsomal antibody type 1 targets CYP2D6 on hepatocyte plasma membrane.

    Science.gov (United States)

    Muratori, L; Parola, M; Ripalti, A; Robino, G; Muratori, P; Bellomo, G; Carini, R; Lenzi, M; Landini, M P; Albano, E; Bianchi, F B

    2000-04-01

    Liver/kidney microsomal antibody type 1 (LKM1) is the marker of type 2 autoimmune hepatitis (AIH) and is detected in up to 6% of patients with hepatitis C virus (HCV) infection. It recognises linear and conformational epitopes of cytochrome P450IID6 (CYP2D6) and may have liver damaging activity, provided that CYP2D6 is accessible to effector mechanisms of autoimmune attack. The presence of LKM1 in the plasma membrane was investigated by indirect immunofluorescence and confocal laser microscopy of isolated rat hepatocytes probed with 10 LKM1 positive sera (five from patients with AIH and five from patients with chronic HCV infection) and a rabbit polyclonal anti-CYP2D6 serum. Serum from both types of patient stained the plasma membrane of non-permeabilised cells, where the fluorescent signal could be visualised as discrete clumps. Conversely, permeabilised hepatocytes showed diffuse submembranous/cytoplasmic staining. Adsorption with recombinant CYP2D6 substantially reduced plasma membrane staining and LKM1 immunoblot reactivity. Plasma membrane staining of LKM1 colocalised with that of anti-CYP2D6. Immunoprecipitation experiments showed that a single 50 kDa protein recognised by anti-CYP2D6 can be isolated from the plasma membrane of intact hepatocytes. AIH and HCV related LKM1 recognise CYP2D6 exposed on the plasma membrane of isolated hepatocytes. This observation supports the notion that anti-CYP2D6 autoreactivity may be involved in the pathogenesis of liver damage.

  13. Determination of protein carbonyls in plasma, cell extracts, tissue homogenates, isolated proteins: Focus on sample preparation and derivatization conditions.

    Science.gov (United States)

    Weber, Daniela; Davies, Michael J; Grune, Tilman

    2015-08-01

    Protein oxidation is involved in regulatory physiological events as well as in damage to tissues and is thought to play a key role in the pathophysiology of diseases and in the aging process. Protein-bound carbonyls represent a marker of global protein oxidation, as they are generated by multiple different reactive oxygen species in blood, tissues and cells. Sample preparation and stabilization are key steps in the accurate quantification of oxidation-related products and examination of physiological/pathological processes. This review therefore focuses on the sample preparation processes used in the most relevant methods to detect protein carbonyls after derivatization with 2,4-dinitrophenylhydrazine with an emphasis on measurement in plasma, cells, organ homogenates, isolated proteins and organelles. Sample preparation, derivatization conditions and protein handling are presented for the spectrophotometric and HPLC method as well as for immunoblotting and ELISA. An extensive overview covering these methods in previously published articles is given for researchers who plan to measure protein carbonyls in different samples. © 2015 Published by Elsevier Ltd.

  14. Stability assessment and operating parameter optimization on experimental results in very small plasma focus, using sensitivity analysis

    Science.gov (United States)

    Jafari, Hossein; Habibi, Morteza

    2018-04-01

    Regarding the importance of stability in small-scale plasma focus devices for producing the repeatable and strength pinching, a sensitivity analysis approach has been used for applicability in design parameters optimization of an actually very low energy device (84 nF, 48 nH, 8-9.5 kV, ∼2.7-3.7 J). To optimize the devices functional specification, four different coaxial electrode configurations have been studied, scanning an argon gas pressure range from 0.6 to 1.5 mbar via the charging voltage variation study from 8.3 to 9.3 kV. The strength and efficient pinching was observed for the tapered anode configuration, over an expanded operating pressure range of 0.6 to 1.5 mbar. The analysis results showed that the most sensitive of the pinch voltage was associated with 0.88 ± 0.8mbar argon gas pressure and 8.3-8.5 kV charging voltage, respectively, as the optimum operating parameters. From the viewpoint of stability assessment of the device, it was observed that the least variation in stable operation of the device was for a charging voltage range of 8.3 to 8.7 kV in an operating pressure range from 0.6 to 1.1 mbar.

  15. Effect of gas filling pressure and operation energy on ion and neutron emission in a medium energy plasma focus device

    Science.gov (United States)

    Niranjan, Ram; Rout, R. K.; Srivastava, Rohit; Kaushik, T. C.

    2018-03-01

    The effects of gas filling pressure and operation energy on deuterium ions and neutrons have been studied in a medium energy plasma focus device, MEPF-12. The deuterium gas filling pressure was varied from 1 to 10 mbar at an operation energy of 9.7 kJ. Also, the operation energy was varied from 3.9 to 9.7 kJ at a deuterium gas filling pressure of 4 mbar. Time resolved emission of deuterium ions was measured using a Faraday cup. Simultaneously, time integrated and time resolved emissions of neutrons were measured using a silver activation detector and plastic scintillator detector, respectively. Various characteristics (fluence, peak density, and most probable energy) of deuterium ions were estimated using the Faraday cup signal. The fluence was found to be nearly independent of the gas filling pressure and operation energy, but the peak density and most probable energy of deuterium ions were found to be varying. The neutron yield was observed to be varying with the gas filling pressure and operation energy. The effect of ions on neutrons emission was observed at each operation condition.

  16. Knowing the dense plasma focus - The coming of age (of the PF) with broad-ranging scaling laws

    Science.gov (United States)

    Saw, S. H.; Lee, S.

    2017-03-01

    The dense plasma focus is blessed not only with copious multi-radiations ranging from electron and ion beams, x-rays both soft and hard, fusion neutrons D-D and D-T but also with the property of enhanced compression from radiative collapse leading to HED (high energy density) states. The Lee code has been used in extensive systematic numerical experiments tied to reality through fitting with measured current waveforms and verified through comparison of measured and computed yields and measurements of multi-radiation. The studies have led to establishment of scaling laws with respect to storage energy, discharge current and pinch currents for fusion neutrons, characteristic soft x-rays, all-line radiation and ion beams. These are summarized here together with a first-time presentation of a scaling law of radiatively enhanced compression as a function of atomic number of operational gas. This paper emphasizes that such a broad range of scaling laws signals the coming of age of the DPF and presents a reference platform for planning the many potential applications such as in advanced SXR lithography, materials synthesizing and testing, medical isotopes, imaging and energy and high energy density (HED).

  17. Normal fasting plasma glucose levels and type 2 diabetes in young men.

    Science.gov (United States)

    Tirosh, Amir; Shai, Iris; Tekes-Manova, Dorit; Israeli, Eran; Pereg, David; Shochat, Tzippora; Kochba, Ilan; Rudich, Assaf

    2005-10-06

    The normal fasting plasma glucose level was recently defined as less than 100 mg per deciliter (5.55 mmol per liter). Whether higher fasting plasma glucose levels within this range independently predict type 2 diabetes in young adults is unclear. We obtained blood measurements, data from physical examinations, and medical and lifestyle information from men in the Israel Defense Forces who were 26 to 45 years of age. A total of 208 incident cases of type 2 diabetes occurred during 74,309 person-years of follow-up (from 1992 through 2004) among 13,163 subjects who had baseline fasting plasma glucose levels of less than 100 mg per deciliter. A multivariate model, adjusted for age, family history of diabetes, body-mass index, physical-activity level, smoking status, and serum triglyceride levels, revealed a progressively increased risk of type 2 diabetes in men with fasting plasma glucose levels of 87 mg per deciliter (4.83 mmol per liter) or more, as compared with those whose levels were in the bottom quintile (less than 81 mg per deciliter [4.5 mmol per liter], P for trend <0.001). In multivariate models, men with serum triglyceride levels of 150 mg per deciliter (1.69 mmol per liter) or more, combined with fasting plasma glucose levels of 91 to 99 mg per deciliter (5.05 to 5.50 mmol per liter), had a hazard ratio of 8.23 (95 percent confidence interval, 3.6 to 19.0) for diabetes, as compared with men with a combined triglyceride level of less than 150 mg per deciliter and fasting glucose levels of less than 86 mg per deciliter (4.77 mmol per liter). The joint effect of a body-mass index (the weight in kilograms divided by the square of the height in meters) of 30 or more and a fasting plasma glucose level of 91 to 99 mg per deciliter resulted in a hazard ratio of 8.29 (95 percent confidence interval, 3.8 to 17.8), as compared with a body-mass index of less than 25 and a fasting plasma glucose level of less than 86 mg per deciliter. Higher fasting plasma glucose

  18. Melting experiment on concrete waste using a hollow type plasma torch mounted on furnace

    International Nuclear Information System (INIS)

    Moon, Y. P.; Kim, T. W.; Kim, H. S.; Shin, S. U.; Lee, M. C.

    2000-01-01

    A furnace coupled with a hollow type plasma torch was manufactured and installed in order to develop a volume reduction technology for non-combustible radioactive waste using plasma. A melting test with 10kg of concrete waste was carried out for the evaluation of melting characteristics in the non-transferred operation mode for 20 minutes with the melter. Feeded concrete was completely melted. However, the molten bath was not easily discharged because of its high viscosity. It was found that some molten slag spat from the molten bath was coated on the surface of torch which was mounted vertically inside furnace

  19. MIXED HYALINE VASCULAR AND PLASMA CELL TYPE CASTLEMAN’S DISEASE: REPORT OF A CASE

    Directory of Open Access Journals (Sweden)

    F. Asgarani

    2006-05-01

    Full Text Available Castleman’s disease (angiofollicular lymphoid hyperplasia includes a heterogeneous group of lymphoproliferative disorders. The cause of this disease remains uncertain. There are two types of localized Castleman’s disease: the more common hyaline vascular and the plasma cell types. Mixed variant is an uncommon localized lesion in general population. The lesions can occur in any part of the body that contains lymphoid tissue, although seventy percent are found in the anterior mediastinum. We report a thirty years old boy with Castleman’s disease who presented with fever, anorexia, weight loss,sweating, anemia and abdominal mass. The histologic examination of the biopsy specimens revealed a mixed hyaline vascular and plasma cell type of Castleman’s disease.

  20. Repetitive plasma loads typical for ITER Type-I ELMS; simulation in QSPA Kh-50

    International Nuclear Information System (INIS)

    Tereshin, V.I.; Bandura, A.N.; Byrka, O.V.; Chebotarev, V.V.; Garkusha, I.E.; Makhlaj, V.A.; Solyakov, D.G.; Tsarenko, A.V.; Landman, I.

    2005-01-01

    The power loads on current tokamaks associated with the Type I ELMs generally do not affect the lifetime of divertor elements. However, the ITER ELMs may lead to unacceptable lifetime; their loads are estimated as QELM(1-3) MJ/m 2 at t = 0.1-1 ms and the repetition frequency of an order of 1 Hz (∼ 400 ELMs during each ITER pulse). Such plasma energy loads expected for ITER ELMs are not achieved in existing tokamaks. Therefore powerful plasma accelerators are used at present for study of plasma-target interaction and for numerical models validation. Quasi-steady-state plasma accelerators (QSPA), which characterized by essentially longer duration of plasma stream generation in comparison with pulsed plasma guns, became especially attractive facilities for investigations of plasma-surface interaction in conditions of high heat loads simulating the ITER disruptions and ELMs. The paper presents experimental study of energy characteristics of the plasma streams generated with quasi-steady-state plasma accelerator QSPA Kh-50 and the main features of plasma interaction with material surfaces in dependence on plasma heat loads. The samples of pure sintered tungsten of EU trademark have been exposed to hydrogen plasma streams produced by the accelerator. To estimate the range of tolerable loads the effects of ELMs on the lifetime of plasma facing components have been experimentally simulated for large numbers of impacts with varying energy density. The experiments were performed with up to 450 pulses of the duration of 0.25 ms and the heat loads in the range of 0.5 - 1.2 MJ/m 2 . At this calorimetry (both at plasma stream and at the target surface), piezo-detectors as well as spectroscopy and interferometry measurements were applied to determine the impacting plasma parameters in different regimes of operation. A threshold character of morphological changes on the tungsten surface under the melting in respect to the pulses number is demonstrated. The number of initial

  1. The changes in plasma endothelin after dosing intervention in type 2 diabetes and its clinical significance

    International Nuclear Information System (INIS)

    Yang Xixiu; Sun Jinfeng; Li Lusheng; Wang Shufang; Zhao Xin

    2002-01-01

    To explore the correlation of endothelin (ET), insulin resistance and microvascular complications in type 2 diabetes, the serum concentrations of OGTT, INS, C-P and plasma ET were measured by radioimmunoassay in 30 normal subjects and 82 patients with type 2 diabetes. ET level had a linear negative correlationship with IAI. The level of ET were significantly greater in group with microangiopathy than in group without microangiopathy (P<0.01). Insulin sensitivity are strongly correlated with vascular endothelial cells. The intervention may play an important role in decreasing insulin resistance of type 2 diabetes, and it is a vascular complications

  2. Plasma heme oxygenase-1 concentration is elevated in individuals with type 2 diabetes mellitus.

    Directory of Open Access Journals (Sweden)

    Wei Bao

    Full Text Available BACKGROUND: Circulating concentrations of heme oxygenase-1 (HO-1 have been recently reported to be elevated in several chronic disorders. However, no study has ever examined the association between circulating HO-1 concentrations and type 2 diabetes mellitus (T2DM. METHODS AND FINDINGS: 581 cases with newly-diagnosed T2DM (New-T2DM and 611 comparison controls were recruited in this two-phase case-control study, comprising 420 cases and 429 controls collected in the first phase study and 161 cases and 182 controls in the second phase replication study. Analyses, using both separated data and combined data from the two-phase studies, show that plasma HO-1 concentrations were significantly increased in New-T2DM cases compared to controls (P<0.001. Plasma HO-1 concentrations were significantly correlated with plasma glucose concentrations, HOMA-beta and HOMA-IR (P<0.001. After adjustment for age, sex, BMI and family history of diabetes, the ORs for New-T2DM in the highest quartile of plasma HO-1 concentrations, compared with the lowest, was 8.23 (95% CI 5.55-12.21; P for trend <0.001. The trend remained significant after additional adjustment for fasting plasma glucose/insulin, HOMA-beta/HOMA-IR, TC/TG, smoking, drinking and history of hypertension, and even in further stratification analysis by age, sex, BMI, smoking, drinking and history of hypertension. CONCLUSIONS: Elevated plasma HO-1 concentrations are associated with higher ORs for New-T2DM, which add more knowledge regarding the important role of oxidative stress in T2DM. More consequent studies were warranted to confirm the clinical utility of plasma HO-1, especially in diagnosis and prognosis of T2DM and its complications.

  3. Plasma N-terminal pro B-type natriuretic peptide concentrations in dogs with pulmonic stenosis.

    Science.gov (United States)

    Kobayashi, Keiya; Hori, Yasutomo; Chimura, Syuuichi

    2014-06-01

    The detailed information between plasma N-terminal pro B-type natriuretic peptide (NT-proBNP) concentrations and dogs with pulmonic stenosis (PS) is still unknown. The aim of the present study was to investigate the clinical utility of measuring plasma NT-proBNP concentrations in dogs with PS and to determine whether plasma NT-proBNP concentration could be used to assess disease severity. This retrospective study enrolled 30 client-owned, untreated dogs with PS (asymptomatic [n=23] and symptomatic [n=7]) and 11 healthy laboratory beagles. Results of physical examination, thoracic radiography and echocardiography were recorded. Plasma NT-proBNP concentrations were measured using commercial laboratories. Compared to the healthy control dogs, cardiothoracic ratio was significantly increased in dogs with both asymptomatic and symptomatic PS. Similarly, the ratio of the main pulmonary artery to aorta was significantly decreased in dogs with both asymptomatic and symptomatic PS. The pulmonic pressure gradient in the symptomatic PS dogs was significantly higher than that in the asymptomatic PS dogs. Plasma NT-proBNP concentration was significantly elevated in the symptomatic PS dogs compared to the healthy control dogs and the asymptomatic PS dogs. Furthermore, the Doppler-derived pulmonic pressure gradient was significantly correlated with the plasma NT-proBNP concentration (r=0.78, r(2)=0.61, P764 pmol/l to identify severe PS had a sensitivity of 76.2% and specificity of 81.8%. The plasma NT-proBNP concentration increased by spontaneous PS, i.e. right-sided pressure overload and can be used as an additional method to assess the severity of PS in dogs.

  4. Plasma B-type natriuretic peptide concentration for diagnosis of acute heart failure with renal insufficiency

    Directory of Open Access Journals (Sweden)

    Naila Atik Khan

    2016-07-01

    Full Text Available Background : Plasma B-type natriuretic peptide (BNP is the diagnostic tool for acute heart failure (AHF.This natriu­retic peptide level depends on renal function, through renal metabolism and excretion. Therefore we examined the effect ofrenal impairment on plasma BNP level during diagnosis of AHF.Objective: The objective of the study was to assess the effect of renal dysfunction on plasma BNP level and to determine appropriate cutoff value of plasma BNP to diagnose the patients of AHF with renal insufficiency.Methods: This cross sectional analytical study was conducted in the Depart­ment of Biochemistry Bangabandhu Sheikh Mujib Medical University (BSMMU. The study was done among 90 AHF patients selected from cardiology emergency department during the period of July 2012 to June 2013. After enrollment plasma BNP concentration was measured and eGFR was estimated from serum creatinine by the four parameter Modifica­tion of Diet and Renal Disease (MORD equation and then grouped into two groups on the basis of empirical cut off value of eGFR 60 ml/min/1.73 m2Results: In this study a significant negative correlation was found between plasma BNP evel and eGFR (P<0.001 , with higher BNP levels observed as eGFR declined. The optimal BNP cutoff value for diagno­sis of AHF patients with renal insufficiency was 824 pg/ml. At this cutoff level AHF with renal insufficiency could be diagnosed with sensitivity and specificity of 84% and 71 %, respectively.Conclusions: By adjusting the cutoff value, plasma BNP can be used to diagnose AHF with renal insufficiency with an acceptable sensitivity and specificity.

  5. Air-water ‘tornado’-type microwave plasmas applied for sugarcane biomass treatment

    Science.gov (United States)

    Bundaleska, N.; Tatarova, E.; Dias, F. M.; Lino da Silva, M.; Ferreira, C. M.; Amorim, J.

    2014-02-01

    The production of cellulosic ethanol from sugarcane biomass is an attractive alternative to the use of fossil fuels. Pretreatment is needed to separate the cellulosic material, which is packed with hemicellulose and lignin in cell wall of sugarcane biomass. A microwave ‘tornado’-type air-water plasma source operating at 2.45 GHz and atmospheric pressure has been applied for this purpose. Samples of dry and wet biomass (˜2 g) have been exposed to the late afterglow plasma stream. The experiments demonstrate that the air-water highly reactive plasma environment provides a number of long-lived active species able to destroy the cellulosic wrapping. Scanning electron microscopy has been applied to analyse the morphological changes occurring due to plasma treatment. The effluent gas streams have been analysed by Fourier-transform infrared spectroscopy (FT-IR). Optical emission spectroscopy and FT-IR have been applied to determine the gas temperature in the discharge and late afterglow plasma zones, respectively. The optimal range of the operational parameters is discussed along with the main active species involved in the treatment process. Synergistic effects can result from the action of singlet O2(a 1Δg) oxygen, NO2, nitrous acid HNO2 and OH hydroxyl radical.

  6. Air–water ‘tornado’-type microwave plasmas applied for sugarcane biomass treatment

    International Nuclear Information System (INIS)

    Bundaleska, N; Tatarova, E; Dias, F M; Lino da Silva, M; Ferreira, C M; Amorim, J

    2014-01-01

    The production of cellulosic ethanol from sugarcane biomass is an attractive alternative to the use of fossil fuels. Pretreatment is needed to separate the cellulosic material, which is packed with hemicellulose and lignin in cell wall of sugarcane biomass. A microwave ‘tornado’-type air–water plasma source operating at 2.45 GHz and atmospheric pressure has been applied for this purpose. Samples of dry and wet biomass (∼2 g) have been exposed to the late afterglow plasma stream. The experiments demonstrate that the air–water highly reactive plasma environment provides a number of long-lived active species able to destroy the cellulosic wrapping. Scanning electron microscopy has been applied to analyse the morphological changes occurring due to plasma treatment. The effluent gas streams have been analysed by Fourier-transform infrared spectroscopy (FT-IR). Optical emission spectroscopy and FT-IR have been applied to determine the gas temperature in the discharge and late afterglow plasma zones, respectively. The optimal range of the operational parameters is discussed along with the main active species involved in the treatment process. Synergistic effects can result from the action of singlet O 2 (a  1 Δ g ) oxygen, NO 2 , nitrous acid HNO 2 and OH hydroxyl radical. (paper)

  7. Pedestal Temperature Model for Type III ELMy H-mode Plasma

    International Nuclear Information System (INIS)

    Buangam, W.; Suwanna, S.; Onjun, T.; Poolyarat, N.; Picha, R.; Singhsomroje, W.

    2009-07-01

    Full text: It is widely known that the improved performance of H-mode plasma results mainly from a formation of the pedestal, which is a narrow region of strong pressure gradient near the edge of plasma. A predictive capability for the conditions at the top of the pedestal is important, especially for predictive simulations of future experiments. New models for predicting the temperature values at the top of the pedestal for type III ELMy H-mode plasma are developed by using two different approaches: a theory-based approaches and an empirical approach. For a theory-based approach, a model is developed based on the calculation of thermal energy in the pedestal region and on accepted scaling laws of energy confinement time. For an empirical model, a scaling law for pedestal temperature in terms of plasma controlled parameters, such as plasma current, magnetic field, heating power, is deduced from experimental data. Predictions from these models are compared with experimental data from the Pedestal International Database. Statistical quantities, such as Root-Mean Square Error (RMSE) and offset values, are computed to quantify the predictive capability of the models. It is found that the theory-based model predicts the pedestal temperature values moderately well yielding RMSE between 30% and 40%. The IPB98(y,3) scaling law yields with best agreement with RMSE of 30.4%. The empirical model predicts the pedestal temperature value with better agreement, yield RMSE of 25.9%

  8. Characterization of plasma etching damage on p-type GaN using Schottky diodes

    International Nuclear Information System (INIS)

    Kato, M.; Mikamo, K.; Ichimura, M.; Kanechika, M.; Ishiguro, O.; Kachi, T.

    2008-01-01

    The plasma etching damage in p-type GaN has been characterized. From current-voltage and capacitance-voltage characteristics of Schottky diodes, it was revealed that inductively coupled plasma (ICP) etching causes an increase in series resistance of the Schottky diodes and compensation of acceptors in p-type GaN. We investigated deep levels near the valence band of p-type GaN using current deep level transient spectroscopy (DLTS), and no deep level originating from the ICP etching damage was observed. On the other hand, by capacitance DLTS measurements for n-type GaN, we observed an increase in concentration of a donor-type defect with an activation energy of 0.25 eV after the ICP etching. The origin of this defect would be due to nitrogen vacancies. We also observed this defect by photocapacitance measurements for ICP-etched p-type GaN. For both n- and p-type GaN, we found that the low bias power ICP etching is effective to reduce the concentration of this defect introduced by the high bias power ICP etching

  9. Prevalence of abnormal plasma liver enzymes in older people with Type 2 diabetes.

    Science.gov (United States)

    Morling, J R; Strachan, M W J; Hayes, P C; Butcher, I; Frier, B M; Reynolds, R M; Price, J F

    2012-04-01

    To determine the prevalence and distribution of abnormal plasma liver enzymes in a representative sample of older adults with Type 2 diabetes. Plasma concentrations of alanine aminotransferase, aspartate aminotransferase and γ-glutamyltransferase were measured in a randomly selected, population-based cohort of 1066 men and women aged 60-75 years with Type 2 diabetes (the Edinburgh Type 2 Diabetes Study). Overall, 29.1% (95% CI 26.1-31.8) of patients had one or more plasma liver enzymes above the upper limit of the normal reference range. Only 10.1% of these patients had a prior history of liver disease and a further 12.4% reported alcohol intake above recommended limits. Alanine aminotransferase was the most commonly raised liver enzyme (23.1% of patients). The prevalence of abnormal liver enzymes was significantly higher in men (odds ratio 1.40, 95% CI 1.07-1.83), in the youngest 5-year age band (odds ratio 2.02, 95% CI 1.44-2.84), in patients with diabetes duration enzyme abnormality. The prevalence of elevated liver enzymes in people with Type 2 diabetes is high, with only modest variation between clinically defined patient groups. Further research is required to determine the prognostic value of raised, routinely measured liver enzymes to inform decisions on appropriate follow-up investigations. © 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.

  10. HLA class I sequence-based typing using DNA recovered from frozen plasma.

    Science.gov (United States)

    Cotton, Laura A; Abdur Rahman, Manal; Ng, Carmond; Le, Anh Q; Milloy, M-J; Mo, Theresa; Brumme, Zabrina L

    2012-08-31

    We describe a rapid, reliable and cost-effective method for intermediate-to-high-resolution sequence-based HLA class I typing using frozen plasma as a source of genomic DNA. The plasma samples investigated had a median age of 8.5 years. Total nucleic acids were isolated from matched frozen PBMC (~2.5 million) and plasma (500 μl) samples from a panel of 25 individuals using commercial silica-based kits. Extractions yielded median [IQR] nucleic acid concentrations of 85.7 [47.0-130.0]ng/μl and 2.2 [1.7-2.6]ng/μl from PBMC and plasma, respectively. Following extraction, ~1000 base pair regions spanning exons 2 and 3 of HLA-A, -B and -C were amplified independently via nested PCR using universal, locus-specific primers and sequenced directly. Chromatogram analysis was performed using commercial DNA sequence analysis software and allele interpretation was performed using a free web-based tool. HLA-A, -B and -C amplification rates were 100% and chromatograms were of uniformly high quality with clearly distinguishable mixed bases regardless of DNA source. Concordance between PBMC and plasma-derived HLA types was 100% at the allele and protein levels. At the nucleotide level, a single partially discordant base (resulting from a failure to call both peaks in a mixed base) was observed out of >46,975 bases sequenced (>99.9% concordance). This protocol has previously been used to perform HLA class I typing from a variety of genomic DNA sources including PBMC, whole blood, granulocyte pellets and serum, from specimens up to 30 years old. This method provides comparable specificity to conventional sequence-based approaches and could be applied in situations where cell samples are unavailable or DNA quantities are limiting. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Investigation on the correlationship between plasma homocysteine and blood glucose, insulin levels in patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Ma Zhongwei

    2005-01-01

    Objective: To explore the correlationship between plasma homocysteine and blood glucose, insulin levels in patients with type 2 diabetes mellitus. Methods: Plasma homocysteine (with ELISA), blood glucose (with hexokinase method) and insulin (with RIA) levels were measured in 66 patients with type 2 diabetes mellitus as well as in 35 controls. Results: Plasma homocysteine levels in the diabetic patients (n=66) were significantly higher than those in controls (P<0.01), especially in those patients complicated with nephropathy (n=32). The homocysteine levels were positively correlated with those of blood glucose and insulin (r=0.3515, r=0.3486, both P<0.01). Conclusion: Plasma homocysteine is an independent risk factor for vascular diseases. The levels of plasma cysteine are significantly increased in patients with type 2 diabetes mellitus, especially in those complicated with nephropathy. Therefore, monitoring of plasma homocysteine level changes is clinically useful. (authors)

  12. Pulsed neutron generators based on the sealed chambers of plasma focus design with D and DT fillings

    International Nuclear Information System (INIS)

    Yurkov, D I; Dulatov, A K; Lemeshko, B D; Golikov, A V; Andreev, D A; Mikhailov, Yu V; Prokuratov, I A; Selifanov, A N

    2015-01-01

    Development of neutron generators using plasma focus (PF) chambers is being conducted in the All-Russia Scientific Research Institute of Automatics (VNIIA) during more than 25 years. PF is a source of soft and hard x-rays and neutrons 2.5 MeV (D) or 14 MeV (DT). Pulses of x-rays and neutrons have a duration of about several tens of nanoseconds, which defines the scope of such generators—the study of ultrafast processes. VNIIA has developed a series of pulse neutron generators covering the range of outputs 10 7 –10 12 n/pulse with resources on the order of 10 3 –10 4 switches, depending on purposes. Generators have weights in the range of 30–700 kg, which allows referring them to the class of transportable generators. Generators include sealed PF chambers, whose manufacture was mastered by VNIIA vacuum tube production plant. A number of optimized PF chambers, designed for use in generators with a certain yield of neutrons has been developed. The use of gas generator based on gas absorber of hydrogen isotopes, enabled to increase the self-life and resource of PF chambers. Currently, the PF chambers withstand up to 1000 switches and have the safety of not less than 5 years. Using a generator with a gas heater, significantly increased security of PF chambers, because deuterium-tritium mixture is released only during work, other times it is in a bound state in the working element of the gas generator. (paper)

  13. Effective implantation of light emitting centers by plasma immersion ion implantation and focused ion beam methods into nanosized diamond

    International Nuclear Information System (INIS)

    Himics, L.; Tóth, S.; Veres, M.; Tóth, A.; Koós, M.

    2015-01-01

    Highlights: • Characteristics of nitrogen implantation of nanodiamond using two low ion energy ion implantation methods were compared. • Formation of complex nitrogen-related defect centers was promoted by subsequent helium implantation and heat treatments. • Depth profiles of the implanted ions and the generated vacancies were determined using SRIM calculations. • The presence of nitrogen impurity was demonstrated by Fourier-transform infrared spectroscopic measurements. • A new nitrogen related band was detected in the photoluminescence spectrum of the implanted samples that was attributed to the N3 color center in nanodiamond. - Abstract: Two different implantation techniques, plasma immersion ion implantation and focused ion beam, were used to introduce nitrogen ions into detonation nanodiamond crystals with the aim to create nitrogen-vacancy related optically active centers of light emission in near UV region. Previously samples were subjected to a defect creation process by helium irradiation in both cases. Heat treatments at different temperatures (750 °C, 450 °C) were applied in order to initiate the formation of nitrogen-vacancy related complex centers and to decrease the sp 2 carbon content formed under different treatments. As a result, a relatively narrow and intensive emission band with fine structure at 2.98, 2.83 and 2.71 eV photon energies was observed in the light emission spectrum. It was assigned to the N3 complex defect center. The formation of this defect center can be expected by taking into account the relatively high dose of implanted nitrogen ions and the overlapped depth distribution of vacancies and nitrogen. The calculated depth profiles distribution for both implanted nitrogen and helium by SRIM simulation support this expectation

  14. Focusing on neuronal cell-type specific mechanisms for brain circuit organization, function and dysfunction

    Institute of Scientific and Technical Information of China (English)

    Lu Li

    2017-01-01

    Mammalian brain circuits consist of dynamically interconnected neurons with characteristic morphology, physiology, connectivity and genetics which are often called neuronal cell types. Neuronal cell types have been considered as building blocks of brain circuits, but knowledge of how neuron types or subtypes connect to and interact with each other to perform neural computation is still lacking. Such mechanistic insights are critical not only to our understanding of normal brain functions, such as perception, motion and cognition, but also to brain disorders including Alzheimer's disease, Schizophrenia and epilepsy, to name a few. Thus it is necessary to carry out systematic and standardized studies on neuronal cell-type specific mechanisms for brain circuit organization and function, which will provide good opportunities to bridge basic and clinical research. Here based on recent technology advancements, we discuss the strategy to target and manipulate specific populations of neuronsin vivo to provide unique insights on how neuron types or subtypes behave, interact, and generate emergent properties in a fully connected brain network. Our approach is highlighted by combining transgenic animal models, targeted electrophysiology and imaging with robotics, thus complete and standardized mapping ofin vivo properties of genetically defined neuron populations can be achieved in transgenic mouse models, which will facilitate the development of novel therapeutic strategies for brain disorders.

  15. Pregnancy Associated Plasma Protein-A in Type 2 Diabetic Patient with Peripheral Neuropathy

    International Nuclear Information System (INIS)

    Nosseir, N.M.

    2011-01-01

    Metabolic changes induced by hyperglycemia lead to dysregulation of cytokines control, subclinical inflammation together with oxidative stress associated with diabetes. The aim of this study is to correlate the role of type 2 diabetic neuropathy on serum pregnancy associated plasma protein-A,interleukin-6 and c-reactive protein .The results denoted that both pregnancy associated plasma protein-A and interleukin-6 were significantly increased in those patients with diabetic neuropathy compared with those without neuropathy but while c-reactive proteins showed significant differences between the three groups, the results lead to the conclusion that PAPP-A,IL-6 are useful tests in monitoring the neuropathic complications associated with type 2 diabetes

  16. Chronic Heart Failure and Comorbid Renal Dysfunction - A Focus on Type 2 Cardiorenal Syndrome

    Science.gov (United States)

    Preeti, Jois; Alexandre, Mebazaa; Pupalan, Iyngkaran; Merlin, Thomas C.; Claudio, Ronco

    2016-01-01

    The most important advancements in the Cardiorenal syndrome (CRS) are its definition and subsequent classifications. When the predominant pathology and pathophysiology is the heart, i.e. chronic heart failure (CHF), and where any renal impairment (RI) subsequent to this is secondary, the classification is type 2 CRS. There are unique differences in the pathophysiology and progression of individual subclasses. It is important to understand the evolution of CHF and consequences of subsequent RI as they are becoming increasingly prevalent, aggravate morbidity and mortality and limit many therapeutic options. In this paper we discuss the significance of the type 2 CRS patients in the context of the thematic series. PMID:27280302

  17. Some discussion on the acceleration mechanism of particles in the type-I plasma comet

    International Nuclear Information System (INIS)

    Li Zhongyuan; Guo Sheyu.

    1991-07-01

    Earlier, the large acceleration of plasma (300 cm/s 2 ) were already observed in type-I tail. Recently, the direct measurements for comet G-Z showed that the energy of particle reaches 2x10 5 eV, an energy much higher than the initial energy of comet particles (≤ 2x10 4 eV). So there should be an accelerated process in the comet. 14 refs, 3 figs

  18. Mean energy of ions at outlet of a type Ecr plasma source

    International Nuclear Information System (INIS)

    Gutierrez T, C.; Gonzalez D, J.

    1998-01-01

    In this work it is described the calculations to mean energy of the ions in the extraction zone of a type Ecr plasma source considering the presence of a metallic substrate. This zone is characterized by the existence of a divergent magnetic field. It is showed that mean energy is function as the distance between the outlet and substrate as the value of the external magnetic field. (Author)

  19. Plasma lysophosphatidylcholine levels are reduced in obesity and type 2 diabetes.

    Directory of Open Access Journals (Sweden)

    Melissa N Barber

    Full Text Available BACKGROUND: Obesity and type 2 diabetes (T2DM are associated with increased circulating free fatty acids and triacylglycerols. However, very little is known about specific molecular lipid species associated with these diseases. In order to gain further insight into this, we performed plasma lipidomic analysis in a rodent model of obesity and insulin resistance as well as in lean, obese and obese individuals with T2DM. METHODOLOGY/PRINCIPAL FINDINGS: Lipidomic analysis using liquid chromatography coupled to mass spectrometry revealed marked changes in the plasma of 12 week high fat fed mice. Although a number of triacylglycerol and diacylglycerol species were elevated along with of a number of sphingolipids, a particularly interesting finding was the high fat diet (HFD-induced reduction in lysophosphatidylcholine (LPC levels. As liver, skeletal muscle and adipose tissue play an important role in metabolism, we next determined whether the HFD altered LPCs in these tissues. In contrast to our findings in plasma, only very modest changes in tissue LPCs were noted. To determine when the change in plasma LPCs occurred in response to the HFD, mice were studied after 1, 3 and 6 weeks of HFD. The HFD caused rapid alterations in plasma LPCs with most changes occurring within the first week. Consistent with our rodent model, data from our small human cohort showed a reduction in a number of LPC species in obese and obese individuals with T2DM. Interestingly, no differences were found between the obese otherwise healthy individuals and the obese T2DM patients. CONCLUSION: Irrespective of species, our lipidomic profiling revealed a generalized decrease in circulating LPC species in states of obesity. Moreover, our data indicate that diet and adiposity, rather than insulin resistance or diabetes per se, play an important role in altering the plasma LPC profile.

  20. Study of Au- production in a plasma-sputter type negative ion source

    International Nuclear Information System (INIS)

    Okabe, Yushirou.

    1991-10-01

    A negative ion source of plasma-sputter type has been constructed for the purpose of studying physical processes which take place in the ion source. Negative ions of gold are produced on the gold target which is immersed in an argon discharge plasma and biased negatively with respect to the plasma. The work function of the target surface was lowered by the deposition of Cs on the target. An in-situ method has been developed to determine the work function of the target surface in the ion source under discharge conditions. The observed minimum work function of a cesiated gold surface in an argon plasma was 1.3 eV, when the negative ion production rate took the maximum value. The production rate increased monotonically and saturated when the surface work function was reduced from 1.9 eV to 1.3 eV. The dependence of Au - production rate on the incident ion energy and on the number of the incident ion was studied. From the experimental results, it is shown that the sputtering process is an important physical process for the negative ion production in the plasma-sputter type negative ion source. The energy distribution function was also measured. When the bias voltage was smaller than 280 V, the high energy component in the distribution decreased as the target voltage was decreased. Therefore, the energy spread ΔE, of the observed negative ion energy distribution also decreased. This tendency is also seen in the energy spectrum of Cu atoms sputtered in normal direction by Ar + ions. (J.P.N.)

  1. Wolter type I x-ray focusing mirror using multilayer coatings

    International Nuclear Information System (INIS)

    Chon, Kwon Su; Namba, Yoshiharu; Yoon, Kwon-Ha

    2006-01-01

    A multilayer coating is a useful addition to a mirror in the x-ray region and has been applied to normal incidence mirrors used with soft x rays. When a multilayer coating is used on grazing incidence optics, higher performance can be achieved than without it.Cr/Sc multilayers coated on a Wolter type I mirror substrate for a soft x-ray microscope are considered. The reflectivity and effective solid angle are calculated for Wolter type I mirrors with uniform and laterally graded multilayer coatings. The laterally graded multilayer mirror showed superior x-ray performance, and the multilayer tolerances were relaxed. This multilayer mirror could be especially useful in the soft x-ray microscope intended for biological applications

  2. Spatial and Time Dynamics of Non-Linear Vortices in Plasma Lens for High-Current Ion Beam Focusing

    Science.gov (United States)

    Goncharov, Alexei A.; Maslov, Vasyl I.; Onishchenko, Ivan N.; Tretyakov, Vitalij N.

    2002-11-01

    It is known from numerical simulation (see, for example, [1]) and from experiments (see, for example, [2]), that an electron density bunches as discrete vortices are long - living structures in vacuum. However, in laboratory experiments [2] it has been shown that the vortices are changed faster, when they are submersed in electrons, distributed around them. The charged plasma lens intended for a focussing of high-current ion beams, has the same crossed configuration of a radial electrical and longitudinal magnetic field [3], as only electron plasma. In this lens the vortical turbulence is excited [3]. The vortex - bunch and vortex - hole are rotated in the inverse directions in system of their rest. The instability development in initially homogeneous plasma causes that the vortices are excited by pairs. Namely, if the vortex - bunch of electrons is generated, near the vortex - hole of electrons is also generated. It is shown, that in nonuniform plasma the vortices behave is various in time. Namely, the vortex - bunch goes to area of larger electron density, and the vortex - hole goes to area of smaller electron density. The speed of the vortex - hole is less than speed of the vortex - bunch. It is shown, that the electron vortices, generated in the plasma lens, can result in to formation of spiral distribution of electron density. The physical mechanism of coalescence of electron vortices - bunches is proposed. 1.Driscoll C.F. et al. Plasma Phys. Contr. Fus. Res. 3 (1989) 507. 2.Kiwamoto Y. et al. Non-neutral plasma physics. Princeton. 1999. P. 99-105. 3.Goncharov A. et al. Plasma Phys. Rep. 20 (1994) 499.

  3. A Control Method of Current Type Matrix Converter for Plasma Control Coil Power Supply

    International Nuclear Information System (INIS)

    Shimada, K.; Matsukawa, M.; Kurihara, K.; Jun-ichi Itoh

    2006-01-01

    In exploration to a tokamak fusion reactor, the control of plasma instabilities of high β plasma such as neoclassical tearing mode (NTM), resistive wall mode (RWM) etc., is the key issue for steady-state sustainment. One of the proposed methods to avoid suppressing RWM is that AC current having a phase to work for reduction the RWM growth is generated in a coil (sector coil) equipped spirally on the plasma vacuum vessel. To stabilize RWM, precise and fast real-time feedback control of magnetic field with proper amplitude and frequency is necessary. This implies that an appropriate power supply dedicated for such an application is expected to be developed. A matrix converter as one of power supply candidates for this purpose could provide a solution The matrix converter, categorized in an AC/AC direct converter composed of nine bi-directional current switches, has a great feature that a large energy storage element is unnecessary in comparison with a standard existing AC/AC indirect converter, which is composed of an AC/DC converter and a DC/AC inverter. It is also advantageous in cost and size of its applications. Fortunately, a voltage type matrix converter has come to be available at the market recently, while a current type matrix converter, which is advantageous for fast control of the large-inductance coil current, has been unavailable. On the background above mentioned, we proposed a new current type matrix converter and its control method applicable to a power supply with fast response for suppressing plasma instabilities. Since this converter is required with high accuracy control, the gate control method is adopted to three-phase switching method using middle phase to reduce voltage and current waveforms distortion. The control system is composed of VME-bus board with DSP (Digital Signal Processor) and FPGA (Field Programmable Gate Array) for high speed calculation and control. This paper describes the control method of a current type matrix converter

  4. Valency and type conversion in CuInSe2 with H2 plasma exposure: A photoemission investigation

    International Nuclear Information System (INIS)

    Nelson, A.J.; Frigo, S.P.; Rosenberg, R.

    1993-01-01

    The effect of H 2 plasma exposure on CuInSe 2 was studied by synchrotron radiation soft-x-ray photoemission spectroscopy. The low-power H 2 plasma was generated with a commercial electron cyclotron resonance plasma source using pure H 2 with the plasma exposure being performed at 200 degree C. In situ photoemission measurements were acquired after each plasma exposure in order to observe changes in the valence-band electronic structure as well as changes in the In 4d and Se 3d core lines. The results were correlated in order to relate changes in surface chemistry to the electronic structure. These measurements indicate that the H 2 plasma exposure type converts the CuInSe 2 surface to an n-type surface as well as converting the In +3 valency state to an In +1 valency state

  5. Plasma coenzyme Q10 levels in type 2 diabetic patients with retinopathy

    Science.gov (United States)

    Ates, Orhan; Bilen, Habip; Keles, Sadullah; Alp, H. Hakan; Keleş, Mevlüt Sait; Yıldırım, Kenan; Öndaş, Osman; Pınar, L. Can; Civelekler, Mustafa; Baykal, Orhan

    2013-01-01

    AIM To determine the relationship between proliferative diabetic retinopathy (PDRP) and plasma coenzyme Q10(CoQ10) concentration. METHODS Patients with type 2 diabetes and PDRP were determined to be the case group (n=50). The control group was consist of healthy individuals (n=50). Plasma CoQ10 and malondialdehyde (MDA) levels were measured in both groups. RESULTS Ubiquinone-10 (Coenzyme Q10) levels in PDRP and control subjects are 3.81±1.19µmol/L and 1.91±0.62µmol/L, respectively. Plasma MDA levels in PDRP and control subjects were 8.16±2µmol/L and 3.44±2.08µmol/L, respectively. Ratio of Ubiquinol-10/ubiquinone-10 in PDRP and control subjects were 0.26±0.16 and 1.41±0.68, respectively. CONCLUSION The ratio of ubiquinol-10/ubiquinone-10 is found lower in patients with PDRP. High levels of plasma ubiquinol-10/ubiquinone-10 ratio indicate the protective effect on diabetic retinopathy. PMID:24195048

  6. Plasma coenzyme Q10 levels in type 2 diabetic patients with retinopathy

    Directory of Open Access Journals (Sweden)

    Orhan Ates

    2013-10-01

    Full Text Available AIM: To determine the relationship between proliferative diabetic retinopathy (PDRP and plasma coenzyme Q10(CoQ10 concentration.METHODS: Patients with type 2 diabetes and PDRP were determined to be the case group (n=50. The control group was consist of healthy individuals (n=50. Plasma CoQ10 and malondialdehyde (MDA levels were measured in both groups.RESULTS: Ubiquinone-10 (Coenzyme Q10 levels in PDRP and control subjects are 3.81±1.19µmol/L and 1.91±0.62µmol/L, respectively. Plasma MDA levels in PDRP and control subjects were 8.16±2µmol/L and 3.44±2.08µmol/L, respectively. Ratio of Ubiquinol-10/ubiquinone-10 in PDRP and control subjects were 0.26±0.16 and 1.41±0.68, respectively.CONCLUSION:The ratio of ubiquinol-10/ubiquinone-10 is found lower in patients with PDRP. High levels of plasma ubiquinol-10/ubiquinone-10 ratio indicate the protective effect on diabetic retinopathy.

  7. Role of decreased Plasma Tryptophan in memory deficits observed in Type-I diabetes

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, S.; Tabassum, S.; Haider, S. [University of Karachi (Pakistan). Dept. of Biochemistry

    2013-01-15

    Objective: To investigate the relationship between plasma tryptophan and the occurrence of memory dysfunctions in male and female type 1 diabetics. Methods: The case-control study was conducted at two urban healthcare facilities in Karachi from January to June 2009, and comprised 100 diabetic subjects of among whom were 50 men and 50 women. The controls were also similar in number and gender. A questionnaire was used to evaluate the memory impairment in the subjects. Plasma tryptophan was determined by high performance liquid chromatography with ultra-violet method. Students t-test was used to analyse tryptophan data. Results: There was considerable memory impairment in the cases (n=40) compared to the controls (n=5). Results also showed a significant (p<0.01) decrease in plasma tryptophan levels in both male and female diabetic patients. Conclusions: Diabetic subjects exhibited occurrence of memory impairment with concomitant decline in plasma tryptophan levels. The findings indicate that decreased brain uptake of tryptophan and lowered brain 5-hydroxytryptamine levels may be responsible for the memory deficits seen in diabetics. (author)

  8. Role of decreased Plasma Tryptophan in memory deficits observed in Type-I diabetes

    International Nuclear Information System (INIS)

    Ahmad, S.; Tabassum, S.; Haider, S.

    2013-01-01

    Objective: To investigate the relationship between plasma tryptophan and the occurrence of memory dysfunctions in male and female type 1 diabetics. Methods: The case-control study was conducted at two urban healthcare facilities in Karachi from January to June 2009, and comprised 100 diabetic subjects of among whom were 50 men and 50 women. The controls were also similar in number and gender. A questionnaire was used to evaluate the memory impairment in the subjects. Plasma tryptophan was determined by high performance liquid chromatography with ultra-violet method. Students t-test was used to analyse tryptophan data. Results: There was considerable memory impairment in the cases (n=40) compared to the controls (n=5). Results also showed a significant (p<0.01) decrease in plasma tryptophan levels in both male and female diabetic patients. Conclusions: Diabetic subjects exhibited occurrence of memory impairment with concomitant decline in plasma tryptophan levels. The findings indicate that decreased brain uptake of tryptophan and lowered brain 5-hydroxytryptamine levels may be responsible for the memory deficits seen in diabetics. (author)

  9. Discriminating the hemolytic risk of blood type A plasmas using the complement hemolysis using human erythrocytes (CHUHE) assay.

    Science.gov (United States)

    Cunnion, Kenji M; Hair, Pamela S; Krishna, Neel K; Sass, Megan A; Enos, Clinton W; Whitley, Pamela H; Maes, Lanne Y; Goldberg, Corinne L

    2017-03-01

    The agglutination-based cross-matching method is sensitive for antibody binding to red blood cells but is only partially predictive of complement-mediated hemolysis, which is important in many acute hemolytic transfusion reactions. Here, we describe complement hemolysis using human erythrocytes (CHUHE) assays that directly evaluate complement-mediated hemolysis between individual serum-plasma and red blood cell combinations. The CHUHE assay is used to evaluate correlations between agglutination titers and complement-mediated hemolysis as well as the hemolytic potential of plasma from type A blood donors. Plasma or serum from each type A blood donor was incubated with AB or B red blood cells in the CHUHE assay and measured for free hemoglobin release. CHUHE assays for serum or plasma demonstrate a wide, dynamic range and high sensitivity for complement-mediated hemolysis for individual serum/plasma and red blood cell combinations. CHUHE results suggest that agglutination assays alone are only moderately predictive of complement-mediated hemolysis. CHUHE results also suggest that plasma from particular type A blood donors produce minimal complement-mediated hemolysis, whereas plasma from other type A blood donors produce moderate to high-level complement-mediated hemolysis, depending on the red blood cell donor. The current results indicate that the CHUHE assay can be used to assess complement-mediated hemolysis for plasma or serum from a type A blood donor, providing additional risk discrimination over agglutination titers alone. © 2016 AABB.

  10. Neon dense plasma focus point x-ray source for ≤ 0.25 μm lithography

    International Nuclear Information System (INIS)

    Prasad, R.R.; Krishnan, M.; Berg, K.; Conlon, D.; Mangano, J.

    1994-01-01

    A discharge driven, dense plasma focus (DPF) in neon has been developed at SRL as a point x-ray source for sub-micron lithography. This source is presently capable of delivering ∼25 J/pulse of neon K-shell x-rays (8--14 angstrom) into 4 π steradians with a ∼1.4% wall plug efficiency at a 20 Hz repetition rate. The discharge is produced by a capacitor bank circuit (8 kV, 1.8 kJ) which has a fixed inductance of 11 nH and drives ∼ 320 kA currents into the DPF load, with ∼1 μs rise-times. X-rays are produced when a dense pinch of neon is formed along the axis of the DPF electrodes. The dense neon pinch has been found to be a cigar shaped object, ∼0.3 mm in diameter at the waist and ∼8 mm long on a singe shot. This source wanders slightly from shot to shot in an overall envelope which is ∼0.5--0.75 mm in diameter and ∼8 mm long. The spectrum of x-rays emitted by the pinch has been extensively studied. It has been found that 60% of the total x-ray output is radiated in the H-like and He-like lines centered at 12.9 angstrom and 40% of the output is radiated in the H-like and He-like continuum, centered at 9.8 angstrom. More than 4 x 10 5 discharges using a cooled DPF head have been fired producing x-rays. The variation in the measured x-ray output, over several hundreds of thousands of shots, corresponds to a variation in the dose delivered to a resist 40 cm from the source, of less than 1%. Data showing the measurement of the x-ray output, dose delivered to a resist, spectra of the source output, novel beam line concepts and potential lithographic applications will be presented

  11. Saturation of backward stimulated scattering of laser in kinetic regime: Wavefront bowing, trapped particle modulational instability, and trapped particle self-focusing of plasma waves

    International Nuclear Information System (INIS)

    Yin, L.; Albright, B. J.; Bowers, K. J.; Daughton, W.; Rose, H. A.

    2008-01-01

    Backward stimulated Raman and Brillouin scattering (SRS and SBS) of laser are examined in the kinetic regime using particle-in-cell simulations. The SRS reflectivity measured as a function of the laser intensity in a single hot spot from two-dimensional (2D) simulations shows a sharp onset at a threshold laser intensity and a saturated level at higher intensities, as obtained previously in Trident experiments [D. S. Montgomery et al., Phys. Plasmas 9, 2311 (2002)]. In these simulations, wavefront bowing of electron plasma waves (ion acoustic waves) due to the trapped particle nonlinear frequency shift, which increases with laser intensity, is observed in the SRS (SBS) regime for the first time. Self-focusing from trapped particle modulational instability (TPMI) [H. A. Rose, Phys. Plasmas 12, 12318 (2005)] is shown to occur in both two- and three-dimensional SRS simulations. The key physics underlying nonlinear saturation of SRS is identified as a combination of wavefront bowing, TPMI, and self-focusing of electron plasma waves. The wavefront bowing marks the beginning of SRS saturation and self-focusing alone is sufficient to terminate the SRS reflectivity, both effects resulting from cancellation of the source term for SRS and from greatly increased dissipation rate of the electron plasm waves. Ion acoustic wave bowing also contributes to the SBS saturation. Velocity diffusion by transverse modes and rapid loss of hot electrons in regions of small transverse extent formed from self-focusing lead to dissipation of the wave energy and an increase in the Landau damping rate in spite of strong electron trapping that reduces Landau damping initially. The ranges of wavelength and growth rate associated with transverse breakup of the electron-plasma wave are also examined in 2D speckle simulations as well as in 2D periodic systems from Bernstein-Greene-Kruskal equilibrium and are compared with theory predictions

  12. Antiobesity Pharmacotherapy for Patients with Type 2 Diabetes: Focus on Long-Term Management

    Directory of Open Access Journals (Sweden)

    Won Seon Jeon

    2014-12-01

    Full Text Available Type 2 diabetes and obesity have a complex relationship; obesity is linked to insulin resistance, the precursor to type 2 diabetes. The management of obesity is an important method to delay onset of diabetes and improve the glycemic durability of antidiabetic agents. However, insulin and some of the oral hypoglycemic agents used to treat diabetes cause significant weight gain, and it is difficult for patients with diabetes to reduce and maintain their weight by life-style changes alone. Thus, antiobesity medications or bariatric surgery may be a necessary adjunct for certain obese patients with diabetes. In 2012, the U.S. Food and Drug Administration (FDA approved lorcaserin and phentermine/topiramate extended-release for the management of chronic weight, and approval for naltrexone/bupropion sustained-release as an adjunct to exercise and reduced caloric intake followed in 2014. Liraglutide is pending FDA approval for antiobesity drug. Here we review the efficacy of approved and new promising drugs for the management of obesity.

  13. An adiabatic focuser

    International Nuclear Information System (INIS)

    Chen, P.; Oide, K.; Sessler, A.M.; Yu, S.S.

    1989-08-01

    Theoretical analysis is made of an intense relativistic electron beam, such as would be available from a linear collider, moving through a plasma of increasing density, but density always less than that of the beam (underdense). In this situation, the plasma electrons are expelled from the beam channel and the electrons are subject to an ever-increasing focusing force provided by the channel ions. Analysis is made on the beam radiation energy loss in the classical, the transition, and the quantum regimes. It is shown that the focuser is insensitive to the beam energy spread behaviors in the nonclassical regimes, the radiation limit on lenses (the Oide limit) can be exceeded. The sensitivity of the system to the topic mismatch and the nonlinearity is also analyzed. Examples are given with SLC-type and TLC-type parameters. 9 refs., 1 tab

  14. Fasting plasma C-peptide, glucagon stimulated plasma C-peptide, and urinary C-peptide in relation to clinical type of diabetes

    DEFF Research Database (Denmark)

    Gjessing, H J; Matzen, L E; Faber, O K

    1989-01-01

    with a fasting plasma C-peptide value less than 0.20 nmol/l, a glucagon stimulated plasma C-peptide value less than 0.32 nmol/l, and a urinary C-peptide value less than 3.1 nmol/l, or less than 0.54 nmol/mmol creatinine/24 h, or less than 5.4 nmol/24 h mainly were Type 1 diabetic patients; while patients with C...

  15. Sun protection attitudes and behaviours among first generation Australians with darker skin types: results from focus groups.

    Science.gov (United States)

    Bryant, Jamie; Zucca, Alison; Brozek, Irena; Rock, Vanessa; Bonevski, Billie

    2015-02-01

    Despite residing in a country that has the highest rates of skin cancer in the world, little is known about the knowledge, attitudes and sun protection practices of first generation Australian-born individuals with olive and darker skin types. Six focus groups with first generation Australian-born individuals of Asian, Mediterranean, Middle Eastern and Indian background were conducted. Participants had good knowledge of the dangers of skin cancer. Most correctly perceived darker skin types as protective and believed they were at low risk of skin cancer. Most participants could recall high profile mass media sun protection campaigns. Several participants suggested that greater representation of ethnic minorities and/or individuals with darker skin types would increase the personal relevance of campaigns. Beliefs that sun protection is not necessary on the basis of skin type highlights the need for further studies to explore fundamental differences in attitudes and practices between those with olive and darker skin and the general Australian population.

  16. TVA - Thermionic Vacuum Arc - A new type of discharge generating pure metal vapor plasma

    International Nuclear Information System (INIS)

    Musa, G.; Popescu, A.; Mustata, I.; Borcoman, I.; Cretu, M.; Leu, G.F.; Salambas, A.; Ehrich, H.; Schumann, I.

    1996-01-01

    In this paper it is presented a new type of discharge in vacuum conditions generating pure metal vapor plasma with energetic metal ions content. The peculiarities of this heated cathode discharge are described and the dependence of the measured ion energy of the working parameters are established. The ion energy value can be easily and smoothly changed. A nearly linear dependence between energy of ions and arc voltage drop has been observed. The ion energy can be increased by the increase of the interelectrode distance, decrease of cathode temperature, change of the relative position of the electrodes and by the decrease of the arc discharge current. A special configuration with cylindrical geometry has been used to develop a small size and compact metal vapour plasma gun. Due to the mentioned peculiarities, this discharge offers new openings for important applications. (author)

  17. Plasma copeptin as marker of cardiovascular disease in asymptomatic type 2 diabetes patients

    DEFF Research Database (Denmark)

    Bar-Shalom, Dana; Poulsen, Mikael K; Rasmussen, Lars M

    2014-01-01

    Recently, copeptin was found associated with cardiovascular disease (CVD) and all-cause mortality in type 2 diabetes mellitus (T2DM) patients treated in primary care. This study aimed to evaluate whether plasma copeptin correlated to CVD in asymptomatic T2DM patients intensively investigated....... A variety of clinical investigations were performed, including blood pressure measurements, carotid intima media thickness evaluation and myocardial perfusion scintigraphy. Blood sample analyses included copeptin measurements. Median plasma copeptin concentrations were similar in the T2DM group...... for sub-clinical CVD. A total of 302 T2DM patients referred to the Diabetes Clinic at Odense University Hospital, Denmark, entered the study. None of the patients had known or suspected CVD. As a control group, 30 healthy adults were recruited from the DanRisk study - a random sample of middle-aged Danes...

  18. The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

    Science.gov (United States)

    Cornish, S.; Khachan, J.

    2016-02-01

    A new and simple type of electron gun is presented. Unlike conventional electron guns, which require a heated filament or extractor, accelerator and focusing electrodes, this gun uses the collimated electron microchannels of an inertial electrostatic confinement (IEC) discharge to achieve the same outcome. A cylindrical cathode is placed coaxially within a cylindrical anode to create the discharge. Collimated beams of electrons and fast neutrals emerge along the axis of the cylindrical cathode. This geometry isolates one of the microchannels that emerge in a negatively biased IEC grid. The internal operating pressure range of the gun is 35-190 mTorr. A small aperture separates the gun from the main vacuum chamber in order to achieve a pressure differential. The chamber was operated at pressures of 4-12 mTorr. The measured current produced by the gun was 0.1-3 mA (0.2-14 mA corrected measurement) for discharge currents of 1-45 mA and discharge voltages of 0.5-12 kV. The collimated electron beam emerges from the aperture into the vacuum chamber. The performance of the gun is unaffected by the pressure differential between the vacuum chamber and the gun. This allows the aperture to be removed and the chamber pressure to be equal to the gun pressure if required.

  19. The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

    International Nuclear Information System (INIS)

    Cornish, S.; Khachan, J.

    2016-01-01

    A new and simple type of electron gun is presented. Unlike conventional electron guns, which require a heated filament or extractor, accelerator and focusing electrodes, this gun uses the collimated electron microchannels of an inertial electrostatic confinement (IEC) discharge to achieve the same outcome. A cylindrical cathode is placed coaxially within a cylindrical anode to create the discharge. Collimated beams of electrons and fast neutrals emerge along the axis of the cylindrical cathode. This geometry isolates one of the microchannels that emerge in a negatively biased IEC grid. The internal operating pressure range of the gun is 35-190 mTorr. A small aperture separates the gun from the main vacuum chamber in order to achieve a pressure differential. The chamber was operated at pressures of 4-12 mTorr. The measured current produced by the gun was 0.1-3 mA (0.2-14 mA corrected measurement) for discharge currents of 1-45 mA and discharge voltages of 0.5-12 kV. The collimated electron beam emerges from the aperture into the vacuum chamber. The performance of the gun is unaffected by the pressure differential between the vacuum chamber and the gun. This allows the aperture to be removed and the chamber pressure to be equal to the gun pressure if required. (paper)

  20. Plasma glucosylceramide and ceramide in type 1 Gaucher disease patients: correlations with disease severity and response to therapeutic intervention

    NARCIS (Netherlands)

    Groener, J. E. M.; Poorthuis, B. J. H. M.; Kuiper, S.; Hollak, C. E. M.; Aerts, J. M. F. G.

    2008-01-01

    The concentrations of plasma glucosylceramide (GlcCer) and ceramide (Cer) were determined in a cohort of type 1 Gaucher disease patients. In plasma of untreated patients, GlcCer concentrations were on average 3-fold increased (median Gaucher: 17.5 nmol/ml, range: 6.5-45.5 (n=27); median control: 5.9