  1. Design of a 500-kJ Mather-type plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Heidarnia, A., E-mail: a-heidarnia@yahoo.com; Sadighzadeh, A.; Zaeem, A. A.; Damideh, V. [Nuclear Science and Technology Research Institute, Plasma Physics and Nuclear Fusion Research School (Iran, Islamic Republic of)

    2016-12-15

    In this article, design of a 500-kJ Mather-type plasma focus device to achieve 10{sup 11} neutrons/shot is reported. One of its important characteristics is the triple-part anode design. The anode is surrounded by an alumina insulator. The second part of the anode is changeable in order to locate cylindrical, conical, or other shapes of pieces mounted on it. This geometry leads to the easier investigation of the neutron and X-ray emissions of the device. The third part of the anode is for changing the materials exposed to different kinds of radiations. The design parameters are considered by semiempirical and empirical formulas and are sketched by Solidworks software. Also, the peak current and neutron yield are estimated.

  2. Design of a 500-kJ Mather-type plasma focus device

    Science.gov (United States)

    Heidarnia, A.; Sadighzadeh, A.; Zaeem, A. A.; Damideh, V.

    2016-12-01

    In this article, design of a 500-kJ Mather-type plasma focus device to achieve 1011 neutrons/shot is reported. One of its important characteristics is the triple-part anode design. The anode is surrounded by an alumina insulator. The second part of the anode is changeable in order to locate cylindrical, conical, or other shapes of pieces mounted on it. This geometry leads to the easier investigation of the neutron and X-ray emissions of the device. The third part of the anode is for changing the materials exposed to different kinds of radiations. The design parameters are considered by semiempirical and empirical formulas and are sketched by Solidworks software. Also, the peak current and neutron yield are estimated.

  3. Dense Plasma Focus Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hui [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Li, Shengtai [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jungman, Gerard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hayes-Sterbenz, Anna Catherine [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-31

    The mechanisms for pinch formation in Dense Plasma Focus (DPF) devices, with the generation of high-energy ions beams and subsequent neutron production over a relatively short distance, are not fully understood. Here we report on high-fidelity 2D and 3D numerical magnetohydrodynamic (MHD) simulations using the LA-COMPASS code to study the pinch formation dynamics and its associated instabilities and neutron production.

  4. Energy spectrum of argon ions emitted from Filippov type Sahand plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadnejad, M.; Pestehe, S. J.; Mohammadi, M. A. [Department of Atomic and Molecular Physics, Faculty of Physics, University of Tabriz, Postal Code 5166614766, Tabriz (Iran, Islamic Republic of); Research Institute for Applied Physics and Astronomy, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2013-07-15

    The energy and flux of the argon ions produced in Sahand plasma focus have been measured by employing a well-designed Faraday cup. The secondary electron emission effects on the ion signals are simulated and the dimensions of Faraday cup are optimized to minimize these effects. The measured ion energy spectrum is corrected for the ion energy loss and charge exchange in the background gas. The effects of the capacitor bank voltage and working gas pressure on the ion energy spectrum are also investigated. It has been shown that the emitted ion number per energy increases as the capacitor bank voltage increases. Decreasing the working gas pressure leads to the increase in the number of emitted ion per energy.

  5. Energy spectrum of argon ions emitted from Filippov type Sahand plasma focus

    Science.gov (United States)

    Mohammadnejad, M.; Pestehe, S. J.; Mohammadi, M. A.

    2013-07-01

    The energy and flux of the argon ions produced in Sahand plasma focus have been measured by employing a well-designed Faraday cup. The secondary electron emission effects on the ion signals are simulated and the dimensions of Faraday cup are optimized to minimize these effects. The measured ion energy spectrum is corrected for the ion energy loss and charge exchange in the background gas. The effects of the capacitor bank voltage and working gas pressure on the ion energy spectrum are also investigated. It has been shown that the emitted ion number per energy increases as the capacitor bank voltage increases. Decreasing the working gas pressure leads to the increase in the number of emitted ion per energy.

  6. Neutron production with mixture of deuterium and krypton in Sahand Filippov type plasma focus facility

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadi, M.A., E-mail: mohammadidorbash@yahoo.com [Department of Atomic and Molecular Physics, Faculty of Physics, University of Tabriz, Tabriz (Iran, Islamic Republic of); Research Institute for Applied Physics and Astronomy, University of Tabriz, Tabriz (Iran, Islamic Republic of); Sobhanian, S. [Department of Atomic and Molecular Physics, Faculty of Physics, University of Tabriz, Tabriz (Iran, Islamic Republic of); Research Institute for Applied Physics and Astronomy, University of Tabriz, Tabriz (Iran, Islamic Republic of); Rawat, R.S. [Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University (Singapore)

    2011-08-01

    This Letter reports the order of magnitude enhancement in neutron yield from Sahand plasma focus device with krypton seeded deuterium operation. The highest average neutron yield of 2.2x10{sup 9} neutrons per shot was achieved at 1.00 Torr deuterium with 3% krypton which is higher than the best average neutron yield of 3.18x10{sup 8} neutrons per shot for pure deuterium operation. Estimation of average neutron energy showed that the maximum and minimum average energies are 2.98±0.6 MeV at 16 kV in 0.25 Torr deuterium with 3% Kr and 2.07±0.2 MeV at 18 kV operation in 0.5 Torr deuterium with 3% Kr, respectively. The anisotropy of neutron emission from Sahand DPF showed that the neutrons are produced mainly by beam-target mechanisms. -- Highlights: → The highest average neutron yield of 2.2x10{sup 9} neutrons per shot was achieved at mixture of deuterium and krypton. → In the krypton seeding of deuterium also anisotropy of neutron emission deuterium is found. → The krypton seeding of deuterium made the neutron emission more reliable over wider operating pressure ranges.

  7. Global parameter optimization of Mather type plasma focus in the framework of the Gratton-Vargas two-dimensional snowplow model

    CERN Document Server

    Auluck, S K H

    2014-01-01

    Dense Plasma Focus (DPF) is known to produce highly energetic ions, electrons and plasma environment which can be used for breeding of short-lived isotopes, plasma nanotechnology and other material processing applications. Commercial utilization of DPF in such areas would need a design tool which can be deployed in an automatic search for the best possible device configuration for a given application. The recently revisited [S K H Auluck, Physics of Plasmas 20, 112501 (2013)] Gratton-Vargas (GV) two-dimensional analytical snowplow model of plasma focus provides a numerical formula for dynamic inductance of a Mather type plasma focus fitted to thousands of automated computations, which enables construction of such design tool. This inductance formula is utilized in the present work to explore global optimization, based on first-principles optimality criteria, in a 4-dimensional parameter-subspace of the zero-resistance GV model. The optimization process is shown to reproduce the empirically observed constancy ...

  8. Construction and experimental study of a 2.5 kJ, simply configured, Mather type plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Shirani, B.; Abbasi, F. [Shahid Beheshti University, Tehran (Iran, Islamic Republic of). Radiation Application Department

    2010-06-15

    In this work, a 2.5 kJ plasma focus device (named as SBUPF1) has been constructed on the basis of a simple configuration. The most important characteristics of this configuration is relative simplicity and using less components in its structure compared with common configurations. SBUPF1 has been tested between 18- 25 kV and wide range of pressure for various gases including Argon, Neon and Deuterium. The system shows consistent and reproducible plasma focusing action as well as fusion neutron production (when deuterium is used as working gas). (author)

  9. Compression between ion and hard x-ray emissions from nitrogen and argon in Mather type plasma focus device

    Directory of Open Access Journals (Sweden)

    S Paghe

    2016-12-01

    Full Text Available In this study, some characteristics of a Mather type Plasma Focus (PF device such as a discharge current, pinch time, ion flux and hard x-ray intensity has been investigated simultaneously in argon and nitrogen gases separately for various operating gas pressures and charging voltages of capacitor bank. It was observed that pinch phenomena was energy and pressure dependent in current sheath as well as ion and hard x-ray emission intensity. Optimum pressure with maximum ion flux and the most intense hard x-ray showed a nearly linear dependence on the charging voltage of the device. Maximum ion flux was estimated in the order of 1018 ions per steradian in both gases. Hard x-ray emission was registered a little after discharge current and Faraday cup (FC signals. Also, optimum pressure for maximum ion flux was not the same as the pressure for intense hard x-rays. Hard x-ray intensity reached its peak at higher pressures

  10. Global parameter optimization of a Mather-type plasma focus in the framework of the Gratton-Vargas two-dimensional snowplow model

    Science.gov (United States)

    Auluck, S. K. H.

    2014-12-01

    Dense plasma focus (DPF) is known to produce highly energetic ions, electrons and plasma environment which can be used for breeding short-lived isotopes, plasma nanotechnology and other material processing applications. Commercial utilization of DPF in such areas would need a design tool that can be deployed in an automatic search for the best possible device configuration for a given application. The recently revisited (Auluck 2013 Phys. Plasmas 20 112501) Gratton-Vargas (GV) two-dimensional analytical snowplow model of plasma focus provides a numerical formula for dynamic inductance of a Mather-type plasma focus fitted to thousands of automated computations, which enables the construction of such a design tool. This inductance formula is utilized in the present work to explore global optimization, based on first-principles optimality criteria, in a four-dimensional parameter-subspace of the zero-resistance GV model. The optimization process is shown to reproduce the empirically observed constancy of the drive parameter over eight decades in capacitor bank energy. The optimized geometry of plasma focus normalized to the anode radius is shown to be independent of voltage, while the optimized anode radius is shown to be related to capacitor bank inductance.

  11. Electron Temperature Measurement Using PIN Diodes as Detectors to Record the X-ray Pulses from a Low-Energy Mather-Type Plasma Focus

    Institute of Scientific and Technical Information of China (English)

    M. Asif; Amna Ikram

    2004-01-01

    In the experiment to determine the plasma electron temperature, a modified multichannel PIN diodes assembly is used as detectors to record the X-ray pulses from a low-energy Mather-type plasma focus device energized by a 32μF, 15 kV (3.6 k J) single capacitor, with deuterium as a filling gas. The ratio of the integrated bremsstrahlung emission transmitting through foils to the total incident flux as a function of foil thickness at various temperatures is obtained for foil absorbers of material. Using 3μm, 6μm, 9μm,12μm,15μm and 18μm thick aluminium absorbers, the transmitted X-ray flux is detected. By comparing the experimental and theoretical curves through a computer program, the plasma electron temperature is determined. Results show that the deuterium focus plasma electron temperature is about 800 eV.

  12. EDITORIAL: Focus on Plasma Medicine

    Science.gov (United States)

    Morfill, G. E.; Kong, M. G.; Zimmermann, J. L.

    2009-11-01

    'Plasma Healthcare' is an emerging interdisciplinary research topic of rapidly growing importance, exploring considerable opportunities at the interface of plasma physics, chemistry and engineering with life sciences. Some of the scientific discoveries reported so far have already demonstrated clear benefits for healthcare in areas of medicine, food safety, environmental hygiene, and cosmetics. Examples include ongoing studies of prion inactivation, chronic wound treatment and plasma-mediated cancer therapy. Current research ranges from basic physical processes, plasma chemical design, to the interaction of plasmas with (i) eukaryotic (mammalian) cells; (ii) prokaryotic (bacteria) cells, viruses, spores and fungi; (iii) DNA, lipids, proteins and cell membranes; and (iv) living human, animal and plant tissues in the presence of biofluids. Of diverse interests in this new field is the need for hospital disinfection, in particular with respect to the alarming increase in bacterial resistance to antibiotics, the concomitant needs in private practices, nursing homes etc, the applications in personal hygiene—and the enticing possibility to 'design' plasmas as possible pharmaceutical products, employing ionic as well as molecular agents for medical treatment. The 'delivery' of the reactive plasma agents occurs at the gaseous level, which means that there is no need for a carrier medium and access to the treatment surface is optimal. This focus issue provides a close look at the current state of the art in Plasma Medicine with a number of forefront research articles as well as an introductory review. Focus on Plasma Medicine Contents Application of epifluorescence scanning for monitoring the efficacy of protein removal by RF gas-plasma decontamination Helen C Baxter, Patricia R Richardson, Gaynor A Campbell, Valeri I Kovalev, Robert Maier, James S Barton, Anita C Jones, Greg DeLarge, Mark Casey and Robert L Baxter Inactivation factors of spore-forming bacteria using low

  13. Low voltage operation of plasma focus.

    Science.gov (United States)

    Shukla, Rohit; Sharma, S K; Banerjee, P; Das, R; Deb, P; Prabahar, T; Das, B K; Adhikary, B; Shyam, A

    2010-08-01

    Plasma foci of compact sizes and operating with low energies (from tens of joules to few hundred joules) have found application in recent years and have attracted plasma-physics scientists and engineers for research in this direction. We are presenting a low energy and miniature plasma focus which operates from a capacitor bank of 8.4 muF capacity, charged at 4.2-4.3 kV and delivering approximately 52 kA peak current at approximately 60 nH calculated circuit inductance. The total circuit inductance includes the plasma focus inductance. The reported plasma focus operates at the lowest voltage among all reported plasma foci so far. Moreover the cost of capacitor bank used for plasma focus is nearly 20 U.S. dollars making it very cheap. At low voltage operation of plasma focus, the initial breakdown mechanism becomes important for operation of plasma focus. The quartz glass tube is used as insulator and breakdown initiation is done on its surface. The total energy of the plasma focus is approximately 75 J. The plasma focus system is made compact and the switching of capacitor bank energy is done by manual operating switch. The focus is operated with hydrogen and deuterium filled at 1-2 mbar.

  14. A novel technique based on a plasma focus device for nano-porous gallium nitride formation on P-type silicon

    Science.gov (United States)

    Sharifi Malvajerdi, S.; Salar Elahi, A.; Habibi, M.

    2017-04-01

    A new deposition formation was observed with a Mather-type Plasma Focus Device (MPFD). MPFD was unitized to fabricate porous Gallium Nitride (GaN) on p-type Silicon (Si) substrate with a (100) crystal orientation for the first time in a deposition process. GaN was deposited on Si with 4 and 7 shots. The samples were subjected to a 3 phase annealing procedure. First, the semiconductors were annealed in the PFD with nitrogen plasma shots after their deposition. Second, a thermal chemical vapor deposition annealed the samples for 1 h at 1050 °C by nitrogen gas at a pressure of 1 Pa. Finally, an electric furnace annealed the samples for 1 h at 1150 °C with continuous flow of nitrogen. Porous GaN structures were observed by Field emission scanning electron microscopy and atomic force microscopy. Furthermore, X-Ray diffraction analysis was carried out to determine the crystallinity of GaN after the samples were annealed. Energy-Dispersive X-Ray Spectroscopy indicated the amount of gallium, nitrogen, and oxygen due to the self-oxidation of the samples. Photoluminescence spectroscopy revealed emissions at 2.94 eV and 3.39 eV, which shows that hexagonal wurtzite crystal structures were formed.

  15. Synthesis of TiN/a-Si3N4 thin film by using a Mather type dense plasma focus system

    Institute of Scientific and Technical Information of China (English)

    T.Hussain; R.Ahmad; N.Khalid; Z.A.Umar; A.Hussnain

    2013-01-01

    A 2.3 kJ Mather type pulsed plasma focus device was used for the synthesis of a TiN/a-Si3N4 thin film at room temperature.The film was characterized using X-ray diffraction (XRD),X-ray photoelectron spectroscopy (XPS),scanning electron microscopy (SEM),and atomic force microscopy (AFM).The XRD pattern confirms the growth of polycrystalline TiN thin film.The XPS results indicate that the synthesized film is non-stoichiometric and contains titanium nitride,silicon nitride,and a phase of silicon oxy-nitride.The SEM and AFM results reveal that the surface of the synthesized film is quite smooth with 0.59 nm roughness (root-mean-square).

  16. Kinetic Simulations of Dense Plasma Focus Breakdown

    Science.gov (United States)

    Schmidt, A.; Higginson, D. P.; Jiang, S.; Link, A.; Povilus, A.; Sears, J.; Bennett, N.; Rose, D. V.; Welch, D. R.

    2015-11-01

    A dense plasma focus (DPF) device is a type of plasma gun that drives current through a set of coaxial electrodes to assemble gas inside the device and then implode that gas on axis to form a Z-pinch. This implosion drives hydrodynamic and kinetic instabilities that generate strong electric fields, which produces a short intense pulse of x-rays, high-energy (>100 keV) electrons and ions, and (in deuterium gas) neutrons. A strong factor in pinch performance is the initial breakdown and ionization of the gas along the insulator surface separating the two electrodes. The smoothness and isotropy of this ionized sheath are imprinted on the current sheath that travels along the electrodes, thus making it an important portion of the DPF to both understand and optimize. Here we use kinetic simulations in the Particle-in-cell code LSP to model the breakdown. Simulations are initiated with neutral gas and the breakdown modeled self-consistently as driven by a charged capacitor system. We also investigate novel geometries for the insulator and electrodes to attempt to control the electric field profile. The initial ionization fraction of gas is explored computationally to gauge possible advantages of pre-ionization which could be created experimentally via lasers or a glow-discharge. Prepared by LLNL under Contract DE-AC52-07NA27344.

  17. Theoretical Study of a Spherical Plasma Focus

    Science.gov (United States)

    Ay, Yasar

    A theoretical model is developed for two concentric electrodes spherical plasma focus device in order to investigate the plasma sheath dynamics, radiative emission, and the ion properties. The work focuses on the model development of the plasma sheath dynamics and its validation, followed by studying of the radiation effects and the beam-ion properties in such unique geometry as a pulsed source for neutrons, soft and hard x-rays, and electron and ion beams. Chapter 1 is an introduction on fusion systems including plasma focus. Chapter 2 is an extensive literature survey on plasma focus modeling and experiments including the various radiations and their mechanism. Chapter 3 details modeling and validation of the plasma sheath dynamics model with comparison between hydrogen, deuterium, tritium and deuterium-tritium mixture for the production of pulsed neutrons. Chapter 4 is a study of the radiative phase, in which neutron yield is investigated, as well as the predicted beam-ion properties. Chapter 5 summarizes and discusses the results. Chapter 6 provides concluding remarks and proposed future works. The phases of the developed model are the rundown phase I, rundown phase II, the reflected phase and a radiative phase. The rundown phase I starts immediately after the completion of the gas breakdown and ends when the current sheath reaches the equator point of the spherical shape. Then immediately followed by rundown phase II to start and it ends when the shock front hits the axis, which is the beginning of the reflected shock phase. Reflected shock front moves towards the incoming current sheath and meets it which is both the end of the reflected shock phase and the beginning of the radiative phase. After the reflected shock front and the current sheath meet, the current sheath continues to move radially inward by compressing the produced plasma column until it reaches the axis. Since the discharge current contains important information about the plasma dynamic

  18. Design and Construction of a Dense Plasma Focus Device

    Science.gov (United States)

    1976-10-01

    breakdown phase ............ 6 3. Typical device waveforms ........ .................... . 11 4. Fluid models of pinch mechanisms...16 5. Ion trajectory models ........... ...................... 19 6. Fillipov-type plasma focus device ...... ................ ... 22 7...52 14a. Pulse amplifier .......... ......................... ... 56 14b. Triggering circuit for the thyratron tube and spark gap ........ 57 15

  19. Simulations with Conventional and Gas Puff Plasma Focus Devices

    Science.gov (United States)

    Shan, Bing; Liu, Mahe; Lee, Paul; Lee, Sing

    2000-10-01

    An energy consistent plasma focus model is improved by considering the plasma ionization states based on the corona equilibrium. This provides the model with the capability of calculating the plasma dynamics and states for different gases in plasma focus. The model is employed to simulate the behavior of the NX2 plasma focus, with both neon and argon gases. The results show that much lower pressure is required to work with argon for x-ray. The model has also been modified to describe a gas-puff plasma focus based on a measured pressure distribution profile. The simulation result reveals that the gas-puff scheme is more efficient in plasma heating and can improve the stability of the plasma column. By comparing with the published results, agreements have been obtained between the computations and experiments of both machines in the major points regarding plasma dynamics, plasma column stability and appearances, plasma temperatures, and x-ray radiation properties.

  20. Experimental results of breakdown in "Dena" plasma focus device

    Science.gov (United States)

    Goudarzi, Shervin; Hoseinian, S. M.; Raeisdana, A.

    2014-06-01

    In spite of the intense research activities on Plasma Focus devices, the physics of the initial breakdown and surface discharge phase has not been realized completely. In this paper we have analyzed the surface discharge and initial breakdown phase in Filippov-type Plasma Focus Facility "Dena" (90 kJ, 25 kV) on the base of the current and current derivative measured signals by using Argon, Neon and Krypton as working gases at different discharge voltages and gas pressures, and the effects of working conditions (atomic weight, discharge voltage and gas pressure) on the breakdown and surface discharge phase have expressed. Also, on the base of these results, we have investigated about the relation of this phase with final pinch phase.

  1. Dense plasma focus (DPF) accelerated non radio isotopic radiological source

    Energy Technology Data Exchange (ETDEWEB)

    Rusnak, Brian; Tang, Vincent

    2017-01-31

    A non-radio-isotopic radiological source using a dense plasma focus (DPF) to produce an intense z-pinch plasma from a gas, such as helium, and which accelerates charged particles, such as generated from the gas or injected from an external source, into a target positioned along an acceleration axis and of a type known to emit ionizing radiation when impinged by the type of accelerated charged particles. In a preferred embodiment, helium gas is used to produce a DPF-accelerated He2+ ion beam to a beryllium target, to produce neutron emission having a similar energy spectrum as a radio-isotopic AmBe neutron source. Furthermore, multiple DPFs may be stacked to provide staged acceleration of charged particles for enhancing energy, tunability, and control of the source.

  2. Bending and Focusing with Plasmas and Crystals - Potential and Challenges

    CERN Document Server

    Zimmermann, F

    2013-01-01

    This talk review the potential of plasmas and crystals for focusing and bending high-energy charged particle beams. It covers topics like plasma lenses, plasma wigglers, plasma dipoles, crystal channeling & reflection, radiation in crystals, crystal accelerators, crystalline beams and ultimate limitations. Past, ongoing or required R&D efforts are highlighted. Invited presentation at EuCARD'13 "Visions for the Future of Particle Accelerators," CERN, 11 June 2013.

  3. Preliminary Results Of A 600 Joules Small Plasma Focus Device

    Science.gov (United States)

    Lee, S. H.; Yap, S. L.; Wong, C. S.

    2009-07-01

    Preliminary results of a 600 J (3.7 μF, 18 kV) Mather type plasma focus device operated at low pressure will be presented. The discharge is formed between a solid anode with length of 6 cm and six symmetrically and coaxially arranged cathode rods of same lengths. The cathode base is profiled in a knife-edge design and a set of coaxial plasma gun are attached to it in order to initiate the breakdown and enhance the current sheath formation. The experiments have been performed in argon gas under a low pressure condition of several microbars. The discharge current and the voltage across the electrodes during the discharge are measured with high voltage probe and current coil. The current and voltage characteristics are used to determine the possible range of operating pressure that gives good focusing action. At a narrow pressure regime of 9.0±0.5 μbar, focusing action is observed with good reproducibility. Preliminary result of ion beam energy is presented. More work will be carried out to investigate the radiation output.

  4. Dense Plasma Focus - From Alternative Fusion Source to Versatile High Energy Density Plasma Source for Plasma Nanotechnology

    Science.gov (United States)

    Rawat, R. S.

    2015-03-01

    The dense plasma focus (DPF), a coaxial plasma gun, utilizes pulsed high current electrical discharge to heat and compress the plasma to very high density and temperature with energy densities in the range of 1-10 × 1010 J/m3. The DPF device has always been in the company of several alternative magnetic fusion devices as it produces intense fusion neutrons. Several experiments conducted on many different DPF devices ranging over several order of storage energy have demonstrated that at higher storage energy the neutron production does not follow I4 scaling laws and deteriorate significantly raising concern about the device's capability and relevance for fusion energy. On the other hand, the high energy density pinch plasma in DPF device makes it a multiple radiation source of ions, electron, soft and hard x-rays, and neutrons, making it useful for several applications in many different fields such as lithography, radiography, imaging, activation analysis, radioisotopes production etc. Being a source of hot dense plasma, strong shockwave, intense energetic beams and radiation, etc, the DPF device, additionally, shows tremendous potential for applications in plasma nanoscience and plasma nanotechnology. In the present paper, the key features of plasma focus device are critically discussed to understand the novelties and opportunities that this device offers in processing and synthesis of nanophase materials using, both, the top-down and bottom-up approach. The results of recent key experimental investigations performed on (i) the processing and modification of bulk target substrates for phase change, surface reconstruction and nanostructurization, (ii) the nanostructurization of PLD grown magnetic thin films, and (iii) direct synthesis of nanostructured (nanowire, nanosheets and nanoflowers) materials using anode target material ablation, ablated plasma and background reactive gas based synthesis and purely gas phase synthesis of various different types of

  5. Plasma lens experiments at the Final Focus Test Beam

    Energy Technology Data Exchange (ETDEWEB)

    Barletta, B. [California Univ., Los Angeles, CA (United States)]|[Lawrence Berkeley Lab., CA (United States); Chattopadhyay, S. [Lawrence Berkeley Lab., CA (United States); Chen, P. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)] [and others

    1993-04-01

    We intend to carry out a series of plasma lens experiments at the Final Focus Test Beam facility at SLAC. These experiments will be the first to study the focusing of particle beams by plasma focusing devices in the parameter regime of interest for high energy colliders, and is expected to lead to plasma lens designs capable of unprecedented spot sizes. Plasma focusing of positron beams will be attempted for the first time. We will study the effects of lens aberrations due to various lens imperfections. Several approaches will be applied to create the plasma required including laser ionization and beam ionization of a working gas. At an increased bunch population of 2.5 {times} 10{sup 10}, tunneling ionization of a gas target by an electron beam -- an effect which has never been observed before -- should be significant. The compactness of our device should prove to be of interest for applications at the SLC and the next generation linear colliders.

  6. Plasma focus in the limit of low energy

    Energy Technology Data Exchange (ETDEWEB)

    Silva, P.; Soto, L.; Sylvester, G.; Zambra, M. [Comision Chilena de Energia Nuclear, Casilla 188 D, Santiago (Chile); Bruzzone, H.; Clausse, A.; Moreno, C. [Red Interinstitucional de Plasmas Densos y Magnetizados, PLADEMA (Argentina)

    2002-07-01

    In order to achieve the design of a repetitive neutron pulses source for a substance detector, a single shot very small plasma focus device has been designed and constructed. The plasma focus operates in the limit of low energy (160 nF capacitor bank, 25-50 nH, 30-40 kV, 70-130 J). The design of the electrode was assisted by a simple model of a Mather plasma focus. A neutron yield of 10{sup 4} - 10{sup 5} is expected when the discharge is operated with deuterium. (Author)

  7. Image Analysis of Plasma Induced by Focused IR Pulsed Laser

    Directory of Open Access Journals (Sweden)

    Ahmad Hadi Ali

    2011-12-01

    Full Text Available Plasma induced by focused laser beam is very essential especially in laser material interaction. Preliminary study leading to this research has been carried out. A Q-switch Nd:YAG laser was employed as a source of energy. The laser was focused using a wide-angle camera lens. The formation of plasma at the focal region was visualized perpendicularly using a CCD video camera interfaced to an image processing system. The dynamic expansion of the laser plasma was grabbed in conjunction with a high-speed photographic system. The observation results show that the plasma was formed in an ellipsoidal shape. The lateral width and the length of the plasma were found gradually increased

  8. Interaction of powerful hot plasma and fast ion streams with materials in dense plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Chernyshova, M., E-mail: maryna.chernyshova@ipplm.pl [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Gribkov, V.A. [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Institution of Russian Academy of Sciences A.A. Baikov Institute of Metallurgy and Material Science RAS, Moscow (Russian Federation); Kowalska-Strzeciwilk, E.; Kubkowska, M.; Miklaszewski, R.; Paduch, M.; Pisarczyk, T.; Zielinska, E. [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Demina, E.V.; Pimenov, V.N.; Maslyaev, S.A. [Institution of Russian Academy of Sciences A.A. Baikov Institute of Metallurgy and Material Science RAS, Moscow (Russian Federation); Bondarenko, G.G. [National Research University Higher School of Economics (HSE), Moscow (Russian Federation); Vilemova, M.; Matejicek, J. [Institute of Plasma Physics of the CAS, Prague (Czech Republic)

    2016-12-15

    Highlights: • Materials perspective for use in mainstream nuclear fusion facilities were studied. • Powerful streams of hot plasma and fast ions were used to induce irradiation. • High temporal, spatial, angular and spectral resolution available in experiments. • Results of irradiation were investigated by number of analysis techniques. - Abstract: A process of irradiating and ablating solid-state targets with hot plasma and fast ion streams in two Dense Plasma Focus (DPF) devices – PF-6 and PF-1000 was examined by applying a number of diagnostics of nanosecond time resolution. Materials perspective for use in chambers of the mainstream nuclear fusion facilities (mainly with inertial plasma confinement like NIF and Z-machine), intended both for the first wall and for constructions, have been irradiated in these simulators. Optical microscopy, SEM, Atomic Emission Spectroscopy, images in secondary electrons and in characteristic X-ray luminescence of different elements, and X-ray elemental analysis, gave results on damageability for a number of materials including low-activated ferritic and austenitic stainless steels, β-alloy of Ti, as well as two types of W and a composite on its base. With an increase of the number of shots irradiating the surface, its morphology changes from weakly pronounced wave-like structures or ridges to strongly developed ones. At later stages, due to the action of the secondary plasma produced near the target materials they melted, yielding both blisters and a fracturing pattern: first along the grain and then “in-between” the grains creating an intergranular net of microcracks. At the highest values of power flux densities multiple bubbles appeared. Furthermore, in this last case the cracks were developed because of microstresses at the solidification of melt. Presence of deuterium within the irradiated ferritic steel surface nanolayers is explained by capture of deuterons in lattice defects of the types of impurity atoms

  9. Focusing of Intense Laser via Parabolic Plasma Concave Surface

    Science.gov (United States)

    Zhou, Weimin; Gu, Yuqiu; Wu, Fengjuan; Zhang, Zhimeng; Shan, Lianqiang; Cao, Leifeng; Zhang, Baohan

    2015-12-01

    Since laser intensity plays an important role in laser plasma interactions, a method of increasing laser intensity - focusing of an intense laser via a parabolic plasma concave surface - is proposed and investigated by three-dimensional particle-in-cell simulations. The geometric focusing via a parabolic concave surface and the temporal compression of high harmonics increased the peak intensity of the laser pulse by about two orders of magnitude. Compared with the improvement via laser optics approaches, this scheme is much more economic and appropriate for most femtosecond laser facilities. supported by National Natural Science Foundation of China (Nos. 11174259, 11175165), and the Dual Hundred Foundation of China Academy of Engineering Physics

  10. The plasma focus as a tool for plasma-wall-interaction studies

    Science.gov (United States)

    Ramos, G.; Martinez, M.; Herrera, J. J. E.; Castillo, F.

    2015-03-01

    The study of the interaction of magnetized plasmas with candidate materials for fusion reactors, as for example tungsten, is a main topic in fusion research. Many studies simulate the plasma wall interaction using ion beams, while only a few use plasma simulators. Plasma foci can produce dense magnetized plasmas of deuterium and helium among other species. We used the plasma focus Fuego-Nuevo II, to expose tungsten samples to deuterium and helium plasmas. The samples were analysed by means of SEM, RBS and NRA, evidencing surface erosion, surface melting and retention of deuterium in a shallow surface layer of 250 nm amounting 6.5·1016 D/cm2. The plasma temperature has been measured at the position of the samples using a triple Langmuir probe and compared to calculations of a snowplow model. The modelling of the electrode to reach desired plasma parameters is discussed.

  11. Self-sustained focusing of high-density streaming plasma

    Science.gov (United States)

    Bugaev, A.; Dobrovolskiy, A.; Goncharov, A.; Gushenets, V.; Litovko, I.; Naiko, I.; Oks, E.

    2017-01-01

    We describe our observations of the transport through an electrostatic plasma lens of a wide-aperture, high-current, low energy, metal-ion plasma flow produced by a cathodic arc discharge. The lens input aperture was 80 mm, the length of the lens was 140 mm, and there were three electrostatic ring electrodes located in a magnetic field formed by permanent magnets. The lens outer electrodes were grounded and the central electrode was biased up to -3 kV. The plasma was a copper plasma with directed (streaming) ion energy 20-40 eV, and the equivalent ion current was up to several amperes depending on the potential applied to the central lens electrode. We find that when the central lens electrode is electrically floating, the current density of the plasma flow at the lens focus increases by up to 40%-50%, a result that is in good agreement with a theoretical treatment based on plasma-optical principles of magnetic insulation of electrons and equipotentialization along magnetic field lines. When the central lens electrode is biased negatively, an on-axis stream of energetic electrons is formed, which can also provide a mechanism for focusing of the plasma flow. Optical emission spectra under these conditions show an increase in intensity of lines corresponding to both copper atoms and singly charged copper ions, indicating the presence of fast electrons within the lens volume. These energetic electrons, as well as accumulating on-axis and providing ion focusing, can also assist in reducing the microdroplet component in the dense, low-temperature, metal plasma.

  12. Numerical Experiments Providing New Insights into Plasma Focus Fusion Devices

    Directory of Open Access Journals (Sweden)

    Sing Lee

    2010-04-01

    Full Text Available Recent extensive and systematic numerical experiments have uncovered new insights into plasma focus fusion devices including the following: (1 a plasma current limitation effect, as device static inductance is reduced towards very small values; (2 scaling laws of neutron yield and soft x-ray yield as functions of storage energies and currents; (3 a global scaling law for neutron yield as a function of storage energy combining experimental and numerical data showing that scaling deterioration has probably been interpreted as neutron ‘saturation’; and (4 a fundamental cause of neutron ‘saturation’. The ground-breaking insights thus gained may completely change the directions of plasma focus fusion research.

  13. Multi-scaling of the dense plasma focus

    Science.gov (United States)

    Saw, S. H.; Lee, S.

    2015-03-01

    The dense plasma focus is a copious source of multi-radiations with many potential new applications of special interest such as in advanced SXR lithography, materials synthesizing and testing, medical isotopes and imaging. This paper reviews the series of numerical experiments conducted using the Lee model code to obtain the scaling laws of the multi-radiations.

  14. Neutron and Ion Beams Emitted from Plasma Focus (112.5 J) Device

    Science.gov (United States)

    El-Aragi M., G.

    2010-02-01

    Preliminary results of recent experiments performed within the Mather-type 112.5 J plasma focus device are presented. The ion beams from the focus device operated with deuterium filling at 1 mbar were registered using CR-39 solid state nuclear track detectors (SSNTD) and a Faraday cup detector for time-resolved measurements. The time-resolved neutron emission from the focus region measurements was detected with a photomultiplier tube (IP-28) optically coupled with a plastic scintillator NE 102.

  15. Application of an impedance matching transformer to a plasma focus.

    Science.gov (United States)

    Bures, B L; James, C; Krishnan, M; Adler, R

    2011-10-01

    A plasma focus was constructed using an impedance matching transformer to improve power transfer between the pulse power and the dynamic plasma load. The system relied on two switches and twelve transformer cores to produce a 100 kA pulse in short circuit on the secondary at 27 kV on the primary with 110 J stored. With the two transformer systems in parallel, the Thevenin equivalent circuit parameters on the secondary side of the driver are: C = 10.9 μF, V(0) = 4.5 kV, L = 17 nH, and R = 5 mΩ. An equivalent direct drive circuit would require a large number of switches in parallel, to achieve the same Thevenin equivalent. The benefits of this approach are replacement of consumable switches with non-consumable transformer cores, reduction of the driver inductance and resistance as viewed by the dynamic load, and reduction of the stored energy to produce a given peak current. The system is designed to operate at 100 Hz, so minimizing the stored energy results in less load on the thermal management system. When operated at 1 Hz, the neutron yield from the transformer matched plasma focus was similar to the neutron yield from a conventional (directly driven) plasma focus at the same peak current.

  16. A compact plasma focus device and its neutron emission

    Institute of Scientific and Technical Information of China (English)

    王新新; 韩旻; 王志文; 刘坤

    1999-01-01

    A 2.2-kJ compact plasma focus device was developed and its characteristics of neutron emission were investigated. A maximum neutron yield of (3.1 ± 1.5) × 10~7 was obtained at 15 hPa deuterium filling pressure. It was found that the neutron yield Y_n is strongly correlated with the amplitude of the pinch dip in di/dt waveform. The time resolved measurement of the neutron pulse indicated that both the hard X-rays and the neutrons are emitted from plasma focus at the same instant and the width of neutron pulse (FWHM) changes slightly from 50 to 53 ns. The pinch time t_p varies from 1.5 to 16.5 ns and it is usually the case that the shorter t_p, the higher the neutron yield. It was also found that the squirrel cage cathode is better than the tubular cathode.

  17. The Relationship Between Personality Type And Leadership Focus

    Directory of Open Access Journals (Sweden)

    Grant Sieff

    2006-11-01

    Full Text Available Optimising focus is a key success driver for many organisation leaders. The relationship between personality type and leadership focus is examined. Personality type is assessed with Form M of the Myers-Briggs Type Indicator instrument, and leadership focus is explored through the development and application of a Leadership Focus Questionnaire. South African executives form the target population for this study. Both functionalist and interpretive approaches are applied. Three primary theoretical hypotheses about leadership focus, concerning (1 optimising the balance of focus between external and internal priorities, (2 the fit between the leadership personality type and the organisation type, and (3 the capacity to manage a multiple focus, are considered. Results show that Extraverted personality types are more comfortable with the challenges of focus in the leadership role than are Introverted types, and Extraverted, Sensing, Thinking and Judging types experience a greater degree of fit with their organisations than do Introverted, Intuitive, Feeling and Perceiving types.

  18. Current and Perspective Applications of Dense Plasma Focus Devices

    Science.gov (United States)

    Gribkov, V. A.

    2008-04-01

    Dense Plasma Focus (DPF) devices' applications, which are intended to support the main-stream large-scale nuclear fusion programs (NFP) from one side (both in fundamental problems of Dense Magnetized Plasma physics and in its engineering issues) as well as elaborated for an immediate use in a number of fields from the other one, are described. In the first direction such problems as self-generated magnetic fields, implosion stability of plasma shells having a high aspect ratio, etc. are important for the Inertial Confinement Fusion (ICF) programs (e.g. as NIF), whereas different problems of current disruption phenomenon, plasma turbulence, mechanisms of generation of fast particles and neutrons in magnetized plasmas are of great interest for the large devices of the Magnetic Plasma Confinement—MPC (e.g. as ITER). In a sphere of the engineering problems of NFP it is shown that in particular the radiation material sciences have DPF as a very efficient tool for radiation tests of prospect materials and for improvement of their characteristics. In the field of broad-band current applications some results obtained in the fields of radiation material sciences, radiobiology, nuclear medicine, express Neutron Activation Analysis (including a single-shot interrogation of hidden illegal objects), dynamic non-destructive quality control, X-Ray microlithography and micromachining, and micro-radiography are presented. As the examples of the potential future applications it is proposed to use DPF as a powerful high-flux neutron source to generate very powerful pulses of neutrons in the nanosecond (ns) range of its duration for innovative experiments in nuclear physics, for the goals of radiation treatment of malignant tumors, for neutron tests of materials of the first wall, blankets and NFP device's constructions (with fluences up to 1 dpa per a year term), and ns pulses of fast electrons, neutrons and hard X-Rays for brachytherapy.

  19. Understanding neutron production in the deuterium dense plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Appelbe, Brian, E-mail: b.appelbe07@imperial.ac.uk, E-mail: j.chittenden@imperial.ac.uk; Chittenden, Jeremy, E-mail: b.appelbe07@imperial.ac.uk, E-mail: j.chittenden@imperial.ac.uk [The Blackett Laboratory, Imperial College London, SW7 2AZ (United Kingdom)

    2014-12-15

    The deuterium Dense Plasma Focus (DPF) can produce copious amounts of MeV neutrons and can be used as an efficient neutron source. However, the mechanism by which neutrons are produced within the DPF is poorly understood and this limits our ability to optimize the device. In this paper we present results from a computational study aimed at understanding how neutron production occurs in DPFs with a current between 70 kA and 500 kA and which parameters can affect it. A combination of MHD and kinetic tools are used to model the different stages of the DPF implosion. It is shown that the anode shape can significantly affect the structure of the imploding plasma and that instabilities in the implosion lead to the generation of large electric fields at stagnation. These electric fields can accelerate deuterium ions within the stagnating plasma to large (>100 keV) energies leading to reactions with ions in the cold dense plasma. It is shown that the electromagnetic fields present can significantly affect the trajectories of the accelerated ions and the resulting neutron production.

  20. Preionization Techniques in a kJ-Scale Dense Plasma Focus

    Science.gov (United States)

    Povilus, Alexander; Shaw, Brian; Chapman, Steve; Podpaly, Yuri; Cooper, Christopher; Falabella, Steve; Prasad, Rahul; Schmidt, Andrea

    2016-10-01

    A dense plasma focus (DPF) is a type of z-pinch device that uses a high current, coaxial plasma gun with an implosion phase to generate dense plasmas. These devices can accelerate a beam of ions to MeV-scale energies through strong electric fields generated by instabilities during the implosion of the plasma sheath. The formation of these instabilities, however, relies strongly on the history of the plasma sheath in the device, including the evolution of the gas breakdown in the device. In an effort to reduce variability in the performance of the device, we attempt to control the initial gas breakdown in the device by seeding the system with free charges before the main power pulse arrives. We report on the effectiveness of two techniques developed for a kJ-scale DPF at LLNL, a miniature primer spark gap and pulsed, 255nm LED illumination. Prepared by LLNL under Contract DE-AC52-07NA27344.

  1. Self-aligning concave relativistic plasma mirror with adjustable focus

    CERN Document Server

    Tsai, Hai-En; Shaw, Joseph M; Stark, David J; Wang, Xiaoming; Zgadzaj, Rafal; Downer, M C

    2016-01-01

    We report an experimental-computational study of the optical properties of plasma mirrors (PMs) at the incident laser frequency when irradiated directly at relativistic intensity (1e18 < I_0 < 1e19 W/cm^2) by near-normally incident (4 degree), high-contrast, 30 fs, 800 nm laser pulses. We find that such relativistic PMs are highly reflective (0.6 to 0.8), and focus a significant fraction of reflected light to intensity as large as 10I_0 at distance f as small 25 microns from the PM, provided that pre-pulses do not exceed 1e14 W/cm^2 prior to 20 ps before arrival of the main pulse peak. Particle-in-cell simulations show that focusing results from denting of the reflecting surface by light pressure combined with relativistic transparency, and that reflectivity and f can be adjusted by controlling pre-plasma length L over the range 0.5 < L < 3 microns. Pump-probe reflectivity measurements show the PM's focusing properties evolve on a ps time scale.

  2. Dynamics of the plasma current sheath in plasma focus discharges in different gases

    Energy Technology Data Exchange (ETDEWEB)

    Vinogradov, V. P.; Krauz, V. I., E-mail: krauz-vi@nrcki.ru [National Research Center Kurchatov Institute (Russian Federation); Mokeev, A. N. [Project Center ITER (Russian Federation); Myalton, V. V.; Kharrasov, A. M. [National Research Center Kurchatov Institute (Russian Federation)

    2016-12-15

    The shape of the plasma current sheath (PCS) in the final stage of its radial compression, the dynamics of pinching, and the subsequent pinch decay in plasma focus (PF) discharges in different gases are studied using an improved multichannel system of electron-optical plasma photography and a newly elaborated synchronization system. The PCS structure in discharges in heavy gases (Ne, Ar) is found to differ significantly from that in discharges in hydrogen and deuterium. The influence of a heavy gas (Xe) additive to hydrogen and deuterium on the structure and compression dynamics of the PCS is investigated.

  3. Reliable Field Distortion Spark Gap for Plasma Focus

    Institute of Scientific and Technical Information of China (English)

    S.HUSSAIN; M.ZAKAULLAH

    2007-01-01

    A simple,low cost,easily maintained,and reliable field distortion spark gap has been developed to operate at a voltage up to 30 kV.The header construction necessary to attach the spark gap switch to a single 12.5μF,40 kV(10 kJ)capacitor is described.The main features of the spark gap are its wide range of voltage operation,high current capacity,low inductance and long lifetime.The performance of spark gap has been tested in a plasma focus and results are presented in this report.

  4. Development of a mobile and repetitive plasma focus

    Science.gov (United States)

    Rapezzi, L.; Angelone, M.; Pillon, M.; Rapisarda, M.; Rossi, E.; Samuelli, M.; Mezzetti, F.

    2004-05-01

    A plasma focus device aimed at working in environmental conditions not tailored for nuclear equipment has been developed by ENEA. It can operate in deuterium at 1 Hz shot rate, with an average neutron production of 3 × 108 neutrons/shot at 6 kJ of capacitor energy. It is easy to transport and conceived for those industrial purposes where a rather intense neutron generator is required but the use of tritium is forbidden. The machine is designed to be reliable and uniform in emission and to be operated in the field by personnel who are not specialists, to meet the requirements of the possible transformation into a commercial product.

  5. Focused beams of fast neutral atoms in glow discharge plasma

    Science.gov (United States)

    Grigoriev, S. N.; Melnik, Yu. A.; Metel, A. S.; Volosova, M. A.

    2017-06-01

    Glow discharge with electrostatic confinement of electrons in a vacuum chamber allows plasma processing of conductive products in a wide pressure range of p = 0.01 - 5 Pa. To assist processing of a small dielectric product with a concentrated on its surface beam of fast neutral atoms, which do not cause charge effects, ions from the discharge plasma are accelerated towards the product and transformed into fast atoms. The beam is produced using a negatively biased cylindrical or a spherical grid immersed in the plasma. Ions accelerated by the grid turn into fast neutral atoms at p > 0.1 Pa due to charge exchange collisions with gas atoms in the space charge sheaths adjoining the grid. The atoms form a diverging neutral beam and a converging beam propagating from the grid in opposite directions. The beam propagating from the concave surface of a 0.24-m-wide cylindrical grid is focused on a target within a 10-mm-wide stripe, and the beam from the 0.24-m-diameter spherical grid is focused within a 10-mm-diameter circle. At the bias voltage U = 5 kV and p ˜ 0.1 Pa, the energy of fast argon atoms is distributed continuously from zero to eU ˜ 5 keV. The pressure increase to 1 Pa results in the tenfold growth of their equivalent current and a decrease in the mean energy by an order of magnitude, which substantially raises the efficiency of material etching. Sharpening by the beam of ceramic knife-blades proved that the new method for the generation of concentrated fast atom beams can be effectively used for the processing of dielectric materials in vacuum.

  6. Editorial: Focus on Laser- and Beam-Driven Plasma Accelerators

    Science.gov (United States)

    Joshi, Chan; Malka, Victor

    2010-04-01

    The ability of short but intense laser pulses to generate high-energy electrons and ions from gaseous and solid targets has been well known since the early days of the laser fusion program. However, during the past decade there has been an explosion of experimental and theoretical activity in this area of laser-matter interaction, driven by the prospect of realizing table-top plasma accelerators for research, medical and industrial uses, and also relatively small and inexpensive plasma accelerators for high-energy physics at the frontier of particle physics. In this focus issue on laser- and beam-driven plasma accelerators, the latest advances in this field are described. Focus on Laser- and Beam-Driven Plasma Accelerators Contents Slow wave plasma structures for direct electron acceleration B D Layer, J P Palastro, A G York, T M Antonsen and H M Milchberg Cold injection for electron wakefield acceleration X Davoine, A Beck, A Lifschitz, V Malka and E Lefebvre Enhanced proton flux in the MeV range by defocused laser irradiation J S Green, D C Carroll, C Brenner, B Dromey, P S Foster, S Kar, Y T Li, K Markey, P McKenna, D Neely, A P L Robinson, M J V Streeter, M Tolley, C-G Wahlström, M H Xu and M Zepf Dose-dependent biological damage of tumour cells by laser-accelerated proton beams S D Kraft, C Richter, K Zeil, M Baumann, E Beyreuther, S Bock, M Bussmann, T E Cowan, Y Dammene, W Enghardt, U Helbig, L Karsch, T Kluge, L Laschinsky, E Lessmann, J Metzkes, D Naumburger, R Sauerbrey, M. Scḧrer, M Sobiella, J Woithe, U Schramm and J Pawelke The optimum plasma density for plasma wakefield excitation in the blowout regime W Lu, W An, M Zhou, C Joshi, C Huang and W B Mori Plasma wakefield acceleration experiments at FACET M J Hogan, T O Raubenheimer, A Seryi, P Muggli, T Katsouleas, C Huang, W Lu, W An, K A Marsh, W B Mori, C E Clayton and C Joshi Electron trapping and acceleration on a downward density ramp: a two-stage approach R M G M Trines, R Bingham, Z Najmudin

  7. Laser Plasmas : Lie-optic matrix algorithm for computer simulation of paraxial self-focusing in a plasma

    Indian Academy of Sciences (India)

    D Subbarao; R Uma; Kamal Goyal; Sanjeev Goyal; Karuna Batra

    2000-11-01

    Propagation algorithm for computer simulation of stationary paraxial self-focusing laser beam in a medium with saturating nonlinearity is given in Lie-optic form. Accordingly, a very natural piece-wise continuous Lie transformation that reduces to a restricted Lorentz group of the beam results. It gives rise to a matrix method for self-focusing beam propagation that is constructed and implemented. Although the results use plasma nonlinearities of saturable type, and a gaussian initial beam, these results are applicable for other media like linear optical fibers and to more general situations.

  8. Opening switch research on a dense plasma focus

    Science.gov (United States)

    Gerdin, G.

    1987-02-01

    Experiments were performed to enhance power coupling to the load by placing the load electrode opposite the muzzle end of the Dense Plasma Focus plasma gun. The impaler concept, whereby the current sheath is run into a knife edge insulator, was tested in two configurations. However, the power coupled to the load was always less than one tenth that of the experiments where the load was coupled to the breach of the gun. Other load coupling schemes where the load electrode was brought near the outside of the central electrode prevented pinches (voltage surges) when placed too close and the power coupled to the load was reduced when the load electrodes were moved away. The results were not as good as those of the impaler concept. Measurements of the dynamics of the current sheath in various stages were performed and compared with theory. Generally the velocity of the current sheath falls below theoretical expectations suggesting the presence of electrode drag, a phenomenon not present in the model. During the radial collapse phase the model and the experimental estimates of dL/dt are in substantiaL agreement before pinch time but disagree afterward due to two dimensional effects not present in the theory.

  9. MHD modeling of dense plasma focus electrode shape variation

    Science.gov (United States)

    McLean, Harry; Hartman, Charles; Schmidt, Andrea; Tang, Vincent; Link, Anthony; Ellsworth, Jen; Reisman, David

    2013-10-01

    The dense plasma focus (DPF) is a very simple device physically, but results to date indicate that very extensive physics is needed to understand the details of operation, especially during the final pinch where kinetic effects become very important. Nevertheless, the overall effects of electrode geometry, electrode size, and drive circuit parameters can be informed efficiently using MHD fluid codes, especially in the run-down phase before the final pinch. These kinds of results can then guide subsequent, more detailed fully kinetic modeling efforts. We report on resistive 2-d MHD modeling results applying the TRAC-II code to the DPF with an emphasis on varying anode and cathode shape. Drive circuit variations are handled in the code using a self-consistent circuit model for the external capacitor bank since the device impedance is strongly coupled to the internal plasma physics. Electrode shape is characterized by the ratio of inner diameter to outer diameter, length to diameter, and various parameterizations for tapering. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  10. Characterization of bismuth nanospheres deposited by plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, M., E-mail: cscientific2@aec.org.sy [IBA Laboratory, Chemistry Department, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic); Al-Hawat, Sh.; Akel, M. [Physics Department, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic); Mrad, O. [Chemistry Department, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic)

    2015-02-14

    A new method for producing thin layer of bismuth nanospheres based on the use of low energy plasma focus device is demonstrated. Various techniques such as scanning electron microscopy, Rutherford backscattering spectroscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and Raman spectroscopy have been used to characterize the morphology and the composition of the nanospheres. Experimental parameters may be adjusted to favour the formation of bismuth nanospheres instead of microspheres. Therefore, the formation of large surface of homogeneous layer of bismuth nanospheres with sizes of below 100 nm can be obtained. The natural snowball phenomenon is observed to be reproduced in nanoscale where spheres roll over the small nanospheres and grow up to bigger sizes that can reach micro dimensions. The comet-like structure, a reverse phenomenon to snowball is also observed.

  11. Fully kinetic simulations of megajoule-scale dense plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, A.; Link, A.; Tang, V.; Halvorson, C.; May, M. [Lawrence Livermore National Laboratory, Livermore California 94550 (United States); Welch, D. [Voss Scientific, LLC, Albuquerque, New Mexico 87108 (United States); Meehan, B. T.; Hagen, E. C. [National Security Technologies, LLC, Las Vegas, Nevada 89030 (United States)

    2014-10-15

    Dense plasma focus (DPF) Z-pinch devices are sources of copious high energy electrons and ions, x-rays, and neutrons. Megajoule-scale DPFs can generate 10{sup 12} neutrons per pulse in deuterium gas through a combination of thermonuclear and beam-target fusion. However, the details of the neutron production are not fully understood and past optimization efforts of these devices have been largely empirical. Previously, we reported on the first fully kinetic simulations of a kilojoule-scale DPF and demonstrated that both kinetic ions and kinetic electrons are needed to reproduce experimentally observed features, such as charged-particle beam formation and anomalous resistivity. Here, we present the first fully kinetic simulation of a MegaJoule DPF, with predicted ion and neutron spectra, neutron anisotropy, neutron spot size, and time history of neutron production. The total yield predicted by the simulation is in agreement with measured values, validating the kinetic model in a second energy regime.

  12. Plasma motion observations in a very small plasma focus in the limit of low energy

    Energy Technology Data Exchange (ETDEWEB)

    Soto, L.; Silva, P.; Moreno, J. [Comision Chilena de Energia Nuclear, Casilla 188-D Santiago, (Chile); Altamirano, L. [Dicontek, Pasaje Galicia 11365, La Florida, Santiago (Chile); Clausse, A. [PLADEMA, UNCPBA Tandil and Comision Nacional de Energia Atomica (Argentina)

    2003-07-01

    A very small plasma focus device has been designed and constructed. The plasma focus operates in the limit of low energy (160 n F capacitor bank, 65 n H, 20 - 40 kV, {approx} 32 - 100 J). The design of the electrode was assisted by a simple model of a Mather plasma focus. A neutron yield of 10{sup 4} - 10{sup 5} is expected when the discharge is operated with deuterium. Experiments in H{sub 2} has been performed at pressures over the range 0.1 to 2 mbar. The diagnostics used in the experiments include current derivative, voltage monitor, and plasma image using a ICCD camera gated at 5 ns. The umbrella-like current sheath running over the end of the coaxial electrodes and the pinch after the radial collapse can be clearly observed in the photographs. The velocity of the radial collapse is of the order of 10{sup 5} m/s. The observations are similar to the results obtained with devices operating at energies several order of magnitude higher. (Author)

  13. Observation of plasma jets in a table top plasma focus discharge

    Energy Technology Data Exchange (ETDEWEB)

    Pavez, Cristian; Soto, Leopoldo, E-mail: lsoto@cchen.cl [Comisión Chilena de Energía Nuclear, CCHEN, Casilla 188-D, Santiago (Chile); Center for Research and Applications in Plasma Physics and Pulsed Power, P4, Santiago-Talca (Chile); Departamento de Ciencias Físicas, Facultad de Ciencias Exactas, Universidad Andrés Bello, República 220, Santiago (Chile); Pedreros, José [Comisión Chilena de Energía Nuclear, CCHEN, Casilla 188-D, Santiago (Chile); Departamento de Ingeniería Eléctrica, Universidad de Santiago de Chile, Santiago (Chile); Tarifeño-Saldivia, Ariel [Comisión Chilena de Energía Nuclear, CCHEN, Casilla 188-D, Santiago (Chile); Center for Research and Applications in Plasma Physics and Pulsed Power, P4, Santiago-Talca (Chile)

    2015-04-15

    In the last years, medium size Z-pinch experiments operating at tens of kJ are being used to create supersonic plasma jets. Those experiments are produced with wire arrays and radial foils, and they are conducted in generators based on water-filled transmission lines. Also plasma jets have been observed in small X-pinch experiments operating at 1 kJ. In this work, observations of plasma jets produced in a table top plasma focus device by means of optical and digital interferometry are shown. The device was operated at only ∼70 J, achieving 50 kA in 150 ns. The plasma jets were observed after the pinch, in the region close and on the anode, along the axis. The electron density measured from the jets is in the range 10{sup 24}–10{sup 25 }m{sup −3}. From two consecutive plasma images separated 18 ns, the axial jet velocity was measured in the order of 4 × 10{sup 4 }m/s.

  14. Focused ion beams using a high-brightness plasma source

    Science.gov (United States)

    Guharay, Samar

    2002-10-01

    High-brightness ion beams, with low energy spread, have merits for many new applications in microelectronics, materials science, and biology. Negative ions are especially attractive for the applications that involve beam-solid interactions. When negative ions strike a surface, especially an electrically isolated surface, the surface charging voltage is limited to few volts [1]. This property can be effectively utilized to circumvent problems due to surface charging, such as device damage and beam defocusing. A compact plasma source, with the capability to deliver either positive or negative ion beams, has been developed. H- beams from this pulsed source showed brightness within an order of magnitude of the value for beams from liquid-metal ion sources. The beam angular intensity is > 40 mAsr-1 and the corresponding energy spread is 1 Acm-2 and a spot size of 100 nm. Such characteristics of focused beam parameters, using a dc source, will immediately open up a large area of new applications. [1] P. N. Guzdar, A. S. Sharma, S. K. Guharay, "Charging of substrates irradiated by particle beams" Appl. Phys. Lett. 71, 3302 (1997). [2] S. K. Guharay, E. Sokolovsky, J. Orloff, "Characteristics of ion beams from a Penning source for focused ion beam applications" J. Vac. Sci Technol. B17, 2779 (1999).

  15. Scattered ionizing radiations from low-energy focus plasma and radiation dosimetery assessment

    Indian Academy of Sciences (India)

    G M El-Arag; M A Ayad; M A El-Kolaly; W Madcour

    2010-10-01

    Scattered ionizing radiation emissions from a low-energy plasma focus (0.1 kJ Mather-type) device operating with different gases were studied. The plasma focus device was powered by a capacitor bank of 1 F at 18 kV maximum charging voltage. The radiation emissions were investigated using time-integrated thermoluminescence TLD-500. These detectors were calibrated against standard X-ray machine as well as standard sources (60Co and 137Ca). Calibration of detectors showed linear relation over all the region of measurements. It was found that radiation levels would be minimum for different gases, when the gas pressure was between 0.5 and 0.8 Torr. Only helium deviated from this phenomenon as it gave maximum radiation level at 0.8 Torr pressure. It was also found that, for all the gases used, the radiation levels were maximum when the applied voltage was 15 keV.

  16. Type 1 diabetes and obesity in children : Focus on inflammation

    NARCIS (Netherlands)

    Verrijn Stuart, A.A.

    2013-01-01

    Type 1 diabetes (T1D) is an inflammatory disorder as is obesity. This thesis addresses inflammatory features in both conditions, with focus on inflammatory mediators and the role of adipose tissue (AT). The first part, specific aspects of immune tolerance in T1D,focuses on immune (dys) regulation an

  17. Opening Switch Research on a Plasma Focus VI.

    Science.gov (United States)

    1988-02-26

    densi y ( -’cm-3 suggest that th. I asma is at max imu: compress ion. Xna xxmmn1m AVI JulmrW0 51 (a) PLASMA DENSITY (SCALE: 1.0=1.6- 1018CM-3 ) 1.0 .4 7...IEEE inter. Pulsed Power Conf., New Mexico , 350 (1983). 3. F. Venneri, and G. Gerdin, IEEE Int. Conf. on Plasma Sci., St. Louis, MO, 1984, Conf. Record

  18. Experimental study of the performance of a very small repetitive plasma focus device in different working conditions

    Science.gov (United States)

    Goudarzi, S.; Babaee, H.; Esmaeli, A.; Nasiri, A.

    2017-01-01

    SORENA-1 is a very small repetitive Mather-type plasma focus device (20 J) that can operate at frequencies up to 1 Hz. This device has been designed and constructed in the Plasma and Nuclear Fusion Research School of the Nuclear Science and Technology Research Institute of Iran. In this article, the structure of SORENA-1 is described and results of experiments with Ar, Ne, and D2 working gases at several discharge voltages and initial pressures are presented and analyzed.

  19. Focusing of plasma flow in an E cross B discharge

    Science.gov (United States)

    Griswold, Martin; Raitses, Yevgeny; Fisch, Nathaniel J.

    2010-11-01

    ExB discharges can be used to accelerate ions in a quasi-neutral plasma. Large ion fluxes can be produced in this way because there is no space charge limitation, however difficulty in specifying the electric field distribution results in large flow divergence [1]. Recent work has identified new methods to control the flow divergence [2,3]. We present the results of new techniques that are designed to further reduce the divergence. [4pt] [1] A.I. Morozov and V.V. Savelyev, Reviews of Plasma Physics vol. 21, B. B. Kadomtsev and V. D. Shafranov, Eds. New York: Consultants Bureau, 2000. [2] Y. Raitses, L.A. Dorf, A.A. Litvak, and N.J. Fisch, Journal of Applied Physics 88 (2000) 1263. [3] A. Smirnov, Y. Raitses, and N.J. Fisch, IEEE Transactions on Plasma Science 36 (2008) 1998.

  20. Counter-facing plasma focus system as a repetitive and/or long-pulse high energy density plasma source

    Science.gov (United States)

    Aoyama, Yutaka; Nakajima, Mitsuo; Horioka, Kazuhiko

    2009-11-01

    A plasma focus system composed of a pair of counter-facing coaxial plasma guns is proposed as a long-pulse and/or repetitive high energy density plasma source. A proof-of-concept experiment demonstrated that with an assist of breakdown and outer electrode connections, current sheets evolved into a configuration for stable plasma confinement at the center of the electrodes. The current sheets could successively compress and confine the high energy density plasma every half period of the discharge current, enabling highly repetitive light emissions in extreme ultraviolet region with time durations in at least ten microseconds.

  1. Study of Neutron From a Dense Plasma Focus Paco Instrument by Means of Nuclear Tracks Detectors

    Directory of Open Access Journals (Sweden)

    M. Milanese

    2016-08-01

    Full Text Available A most interesting feature of dense plasma foci is the acceleration of charge particle at energy in the range of MeV per nucleon. Using deuterium gas, this devices produce fusion D-D reactions, generation fast neutron pulses (~ 2.5 MeV. The device used in the present work is a Mather-type dense plasma focus, called PACO. It is a 2kJ device at 31 kV, with an oxygen-free copper anode, 50 mm long with 40 mm diameter. The coaxial cathode is formed by ten copper rods arranged in a squirrel cage configuration at a radius of 50mm. The insulator in an annular Pyrex® tube located at the base of the anode. The energy store is provided by four 1 µF (40 kV, 40 nH capacitors in parallel. The plasma focus was operated at 1.5 mb deuterium gas pressure. Neutron and accelerated particles are analyzed with material detectors (CR-39 Lantrack® for different conditions. A detailed study is made of track diameters when the plastic is chemically etched with, 6N KOH at 60°C (±1 for 12 h.

  2. Tapered plasma channels to phase-lock accelerating and focusing forces in laser-plasma accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Rittershofer, W.; Schroeder, C.B.; Esarey, E.; Gruner, F.J.; Leemans, W.P.

    2010-05-17

    Tapered plasma channels are considered for controlling dephasing of a beam with respect to a plasma wave driven by a weakly-relativistic, short-pulse laser. Tapering allows for enhanced energy gain in a single laser plasma accelerator stage. Expressions are derived for the taper, or longitudinal plasma density variation, required to maintain a beam at a constant phase in the longitudinal and/or transverse fields of the plasma wave. In a plasma channel, the phase velocities of the longitudinal and transverse fields differ, and, hence, the required tapering differs. The length over which the tapered plasma density becomes singular is calculated. Linear plasma tapering as well as discontinuous plasma tapering, which moves beams to adjacent plasma wave buckets, are also considered. The energy gain of an accelerated electron in a tapered laser-plasma accelerator is calculated and the laser pulse length to optimize the energy gain is determined.

  3. Comparative study of radiation emission without and with target in a 2.2 kJ plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Muhammad Zubair, E-mail: mzubairkhan-um76@yahoo.com [Plasma Technology Research Center, Department of Physics, Faculty of Science, University Malaya, 50603 Kuala Lumpur Malaysia and Department of Physics, Federal Urdu University of Arts, Science and Technology, 45320 Islamabad (Pakistan); Ling, Yap Seong; San, Wong Chiow [Plasma Technology Research Center, Department of Physics, Faculty of Science, University Malaya, 50603 Kuala Lumpur (Malaysia)

    2014-03-24

    The radiation emission in a 2.2 kJ Mather-type dense plasma focus device is investigated using a five channel BPX65 PIN diode spectrometer. Estimated X-ray associated with the hollow anode without and with target in Argon gas medium is compared. At optimum conditions, the radiation emission from the system is found to be strongly influenced with target in hollow anode and the filling gas pressure. The maximum X-ray yield in 4π sr was obtained in case of hollow anode in argon gas medium with target 'Lead' due to interaction of electron beam. Results indicated that an appropriate design of hollow anode with target could enhance the radiation emission by more intense interaction of expected electron beam with target. The outcomes are helpful in designing a plasma focus with enhanced X-ray radiation with improved shot to shot reproducibility in plasma focus device.

  4. Palm top plasma focus device as a portable pulsed neutron source.

    Science.gov (United States)

    Rout, R K; Niranjan, Ram; Mishra, P; Srivastava, R; Rawool, A M; Kaushik, T C; Gupta, Satish C

    2013-06-01

    Development of a palm top plasma focus device generating (5.2 ± 0.8) × 10(4) neutrons∕pulse into 4π steradians with a pulse width of 15 ± 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 μF capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 μF, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of (3)He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

  5. effect of the plasma ion channel on self-focusing of a Gaussian laser pulse in underdense plasma

    Directory of Open Access Journals (Sweden)

    Sh Irani

    2013-09-01

    Full Text Available  We have considered the self-focusing of a Gaussian laser pulse in unmagnetized plasma. High-intensity electromagnetic fields cause the variation of electron density in plasma. These changes in the special conditions cause the acceleration of electrons to the higher energy and velocities. Thus the equation of plasma density evolution was obtained considering the electrons ponderomotive force. Then, an equation for the width of laser pulse with a relativistic mass correction term and the effect of ion channel were derived and the propagation of high-intensity laser pulse in an underdense plasma with weak relativistic approximation was investigated. It is shown that the ratio of ion channel radius to spot size could result in different forms of self focusing for the laser pulse in plasma.

  6. Confinement effect of cylindrical-separatrix-type magnetic field on the plume of magnetic focusing type Hall thruster

    Science.gov (United States)

    Yu, Daren; Meng, Tianhang; Ning, Zhongxi; Liu, Hui

    2017-04-01

    A magnetic focusing type Hall thruster was designed with a cylindrical magnetic seperatrix. During the process of a hollow cathode crossing the separatrix, the variance of plume parameter distribution was monitored. Results show that the ion flux on the large spatial angle is significantly lower when the hollow cathode is located in the inner magnetic field. This convergence effect is preserved even in a distant area. A mechanism was proposed for plume divergence from the perspective of cathode-to-plume potential difference, through which the confinement effect of cylindrical-separatrix-type magnetic field on thruster plume was confirmed and proposed as a means of plume protection for plasma propulsion devices.

  7. Localized Castleman disease of plasma cell type in the abdomen

    Institute of Scientific and Technical Information of China (English)

    LU Zhi-hua; WU Mei

    2011-01-01

    Castleman disease is a relatively rare entity,with the hyaline-vascular type the predominant form.Although the plasma cell type is uncommon,it still comprises approximately 10% of cases of localized diseases.In addition,the abdomen is a rare site for involvement and localized Castleman disease of the plasma cell type in the abdomen is rare.The radiologic features of localized plasma cell type in the abdomen are mostly limited to case reports.In addition to the conventional imaging findings,we present some new imaging findings of localized plasma cell type in the abdomen.

  8. Strong self-focusing of a cosh-Gaussian laser beam in collisionless magneto-plasma under plasma density ramp

    Energy Technology Data Exchange (ETDEWEB)

    Nanda, Vikas; Kant, Niti, E-mail: nitikant@yahoo.com [Department of Physics, Lovely Professional University, G. T. Road, Phagwara, Punjab 144411 (India)

    2014-07-15

    The effect of plasma density ramp on self-focusing of cosh-Gaussian laser beam considering ponderomotive nonlinearity is analyzed using WKB and paraxial approximation. It is noticed that cosh-Gaussian laser beam focused earlier than Gaussian beam. The focusing and de-focusing nature of the cosh-Gaussian laser beam with decentered parameter, intensity parameter, magnetic field, and relative density parameter has been studied and strong self-focusing is reported. It is investigated that decentered parameter “b” plays a significant role for the self-focusing of the laser beam as for b=2.12, strong self-focusing is seen. Further, it is observed that extraordinary mode is more prominent toward self-focusing rather than ordinary mode of propagation. For b=2.12, with the increase in the value of magnetic field self-focusing effect, in case of extraordinary mode, becomes very strong under plasma density ramp. Present study may be very useful in the applications like the generation of inertial fusion energy driven by lasers, laser driven accelerators, and x-ray lasers. Moreover, plasma density ramp plays a vital role to enhance the self-focusing effect.

  9. Hard X-ray sources from miniature plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Raspa, V. [Buenos Aires Univ., PLADEMA, CONICET and INFIP (Argentina); Silva, P.; Moreno, J.; Zambra, M.; Soto, L. [Comision Chilena de Energia Nuclear, Santiago (Chile)

    2004-07-01

    As first stage of a program to design a repetitive pulsed radiation generator for industrial applications, two miniature plasma foci have been designed and constructed at the Chilean commission of nuclear energy. The devices operate at an energy level of the order of tens of joules (PF-50 J, 160 nF capacitor bank, 20-35 kV, 32-100 J, {approx} 150 ns time to peak current) and hundred of joules (PF-400 J, 880 nF, 20-35 kV, 176-539 J, {approx} 300 ns time to peak current). Hard X-rays are being studied in these devices operating with hydrogen. Images of metallic plates with different thickness were obtained on commercial radiographic film, Agfa Curix ST-G2, in order to characterize the energy of the hard X-ray outside of the discharge chamber of PF-400 J. An effective energy of the order of 90 keV was measured under those conditions. X ray images of different metallic objects also have been obtained. (authors)

  10. Dense plasma focus research at the Institute of Laser Engineering, Osaka (Japan)

    Science.gov (United States)

    Yokoyama, M.; Yamamoto, Y.; Kisoda, A.; Yamada, Y.; Kitagawa, Y.; Yamanaka, M.; Yamanaka, C.

    1983-09-01

    Research using a 50 kV/50 kJ deuterium plasma focus with 1.25 MA maximum current is summarized. Plasma dynamics in implosion phase of dense plasma focus were investigated by 2nsec ruby laser holographic interferometry and shadowgraphy. Radial pinch velocity of the plasma column and ionizing front velocity are 20 million cm/sec. Rayleigh-Taylor instability is observed in the early stage of the implosion phase. Effects of CO2 laser light on a dense plasma focus are discussed. High energy deuteron intensity, energy spectrum, and angular distribution were measured from radioactivity induced in graphite, aliminum and copper in ion dominant low pressure mode and neutron dominant high pressure mode.

  11. Counter-facing plasma focus system as an efficient and long-pulse EUV light source

    Science.gov (United States)

    Kuwabara, H.; Hayashi, K.; Kuroda, Y.; Nose, H.; Hotozuka, K.; Nakajima, M.; Horioka, K.

    2011-04-01

    A plasma focus system composed of a pair of counter-facing coaxial plasma guns is proposed as a long-pulse and efficient EUV light source. A proof-of-concept experiment demonstrated that with an assist of breakdown and outer electrode connections, current sheets evolved into a configuration for stable plasma confinement at the center of the electrode. The current sheets could successively compress and confine the high energy density plasma every half period of the discharge current, enabling highly repetitive light emissions in extreme ultraviolet region with time duration in at least ten microseconds for Xe plasma. Also, we confirmed operations of our system for Li plasma. We estimated the highest EUV energy in Li plasma operation at 93mJ/4π sr per 2% bandwidth per pulse.

  12. Study of the interrelation between the electrotechnical parameters of the plasma focus discharge circuit and the plasma compression dynamics on the PF-3 and PF-1000 facilities

    Energy Technology Data Exchange (ETDEWEB)

    Mitrofanov, K. N., E-mail: mitrkn@inbox.ru [Troitsk Institute for Innovation and Fusion Research (Russian Federation); Krauz, V. I., E-mail: krauz-vi@nrcki.ru, E-mail: vkrauz@yandex.ru [National Research Centre Kurchatov Institute (Russian Federation); Grabovski, E. V. [Troitsk Institute for Innovation and Fusion Research (Russian Federation); Myalton, V. V.; Vinogradov, V. P. [National Research Centre Kurchatov Institute (Russian Federation); Paduch, M. [Institute of Plasma Physics and Laser Microfusion (Poland); Scholz, M. [Polish Academy of Sciences, Niewodniczański Institute of Nuclear Physics (Poland); Karpiński, L. [Łukasiewicz University of Technology, Faculty of Electrical and Computer Engineering (Poland)

    2015-05-15

    The main stages of the plasma current sheath (PCS) dynamics on two plasma focus (PF) facilities with different geometries of the electrode system, PF-3 (Filippov type) and PF-1000 (Mather type), were studied by analyzing the results of the current and voltage measurements. Some dynamic characteristics, such as the PCS velocity in the acceleration phase in the Mather-type facility (PF-1000), the moment at which the PCS reaches the anode end, and the plasma velocity in the radial stage of plasma compression in the PF-3 Filippov-type facility, were determined from the time dependence of the inductance of the discharge circuit with a dynamic plasma load. The energy characteristics of the discharge circuit of the compressing PCS were studied for different working gases (deuterium, argon, and neon) at initial pressures of 1.5–3 Torr in discharges with energies of 0.3–0.6 MJ. In experiments with deuterium, correlation between the neutron yield and the electromagnetic energy deposited directly in the compressed PCS was investigated.

  13. Generation of acoustic rogue waves in dusty plasmas through three-dimensional particle focusing by distorted waveforms

    Science.gov (United States)

    Tsai, Ya-Yi; Tsai, Jun-Yi; I, Lin

    2016-06-01

    Rogue waves--rare uncertainly emerging localized events with large amplitudes--have been experimentally observed in many nonlinear wave phenomena, such as water waves, optical waves, second sound in superfluid He II (ref. ) and ion acoustic waves in plasmas. Past studies have mainly focused on one-dimensional (1D) wave behaviour through modulation instabilities, and to a lesser extent on higher-dimensional behaviour. The question whether rogue waves also exist in nonlinear 3D acoustic-type plasma waves, the kinetic origin of their formation and their correlation with surrounding 3D waveforms are unexplored fundamental issues. Here we report the direct experimental observation of dust acoustic rogue waves in dusty plasmas and construct a picture of 3D particle focusing by the surrounding tilted and ruptured wave crests, associated with the higher probability of low-amplitude holes for rogue-wave generation.

  14. Characterization of plasma-induced cell membrane permeabilization: focus on OH radical distribution

    Science.gov (United States)

    Sasaki, Shota; Honda, Ryosuke; Hokari, Yutaro; Takashima, Keisuke; Kanzaki, Makoto; Kaneko, Toshiro

    2016-08-01

    Non-equilibrium atmospheric-pressure plasma (APP) is used medically for plasma-induced cell permeabilization. However, how plasma irradiation specifically triggers permeabilization remains unclear. In an attempt to identify the dominant factor(s), the distribution of plasma-produced reactive species was investigated, primarily focusing on OH radicals. A stronger plasma discharge, which produced more OH radicals in the gas phase, also produced more OH radicals in the liquid phase (OHaq), enhancing the cell membrane permeability. In addition, plasma irradiation-induced enhancement of cell membrane permeability decreased markedly with increased solution thickness (<1 mm), and the plasma-produced OHaq decayed in solution (diffusion length on the order of several hundred micrometers). Furthermore, the horizontally center-localized distribution of OHaq corresponded with the distribution of the permeabilized cells by plasma irradiation, while the overall plasma-produced oxidizing species in solution (detected by iodine-starch reaction) exhibited a doughnut-shaped horizontal distribution. These results suggest that OHaq, among the plasma-produced oxidizing species, represents the dominant factor in plasma-induced cell permeabilization. These results enhance the current understanding of the mechanism of APP as a cell-permeabilization tool.

  15. Neutron angular distribution in a plasma focus obtained using nuclear track detectors.

    Science.gov (United States)

    Castillo-Mejía, F; Herrera, J J E; Rangel, J; Golzarri, J I; Espinosa, G

    2002-01-01

    The dense plasma focus (DPF) is a coaxial plasma gun in which a high-density, high-temperature plasma is obtained in a focused column for a few nanoseconds. When the filling gas is deuterium, neutrons can be obtained from fusion reactions. These are partially due to a beam of deuterons which are accelerated against the background hot plasma by large electric fields originating from plasma instabilities. Due to a beam-target effect, the angular distribution of the neutron emission is anisotropic, peaked in the forward direction along the axis of the gun. The purpose of this work is to illustrate the use of CR-39 nuclear track detectors as a diagnostic tool in the determination of the time-integrated neutron angular distribution. For the case studied in this work, neutron emission is found to have a 70% contribution from isotropic radiation and a 30% contribution from anisotropic radiation.

  16. Concrete shielding of neutron radiations of plasma focus and dose examination by FLUKA

    Science.gov (United States)

    Nemati, M. J.; Amrollahi, R.; Habibi, M.

    2013-07-01

    Plasma Focus (PF) is among those devices which are used in plasma investigations, but this device produces some dangerous radiations after each shot, which generate a hazardous area for the operators of this device; therefore, it is better for the operators to stay away as much as possible from the area, where plasma focus has been placed. In this paper FLUKA Monte Carlo simulation has been used to calculate radiations produced by a 4 kJ Amirkabir plasma focus device through different concrete shielding concepts with various thicknesses (square, labyrinth and cave concepts). The neutron yield of Amirkabir plasma focus at varying deuterium pressure (3-9 torr) and two charging voltages (11.5 and 13.5 kV) is (2.25 ± 0.2) × 108 neutrons/shot and (2.88 ± 0.29) × 108 neutrons/shot of 2.45 MeV, respectively. The most influential shield for the plasma focus device among these geometries is the labyrinth concept on four sides and the top with 20 cm concrete.

  17. Ion beam emission within a low energy focus plasma (0.1 kJ) operating with hydrogen

    Energy Technology Data Exchange (ETDEWEB)

    El-Aragi, Gamal E. [Nuclear Research Center, Cairo (Egypt). Plasma Physics and Nuclear Fusion Dept.

    2010-06-15

    An investigation of energetic ion beam emission from a low energy plasma focus (0.1 kJ Mather type) device operating with hydrogen gas is studied. The ion beam emission is investigated using time-integrated and time-resolved detectors. The present plasma focus device is powered by a capacitor bank of 1 {mu}F at 18 kV maximum charging voltage. The correlation of ion beam intensity with filling gas pressure indicates that the beam emission is maximized at the optimum pressure for the focus formation at peak current. Energy of ions is determined with a time-of-flight (TOF) method, taking into account distance from the center electrode to the detection plane. (orig.)

  18. Surface modifications of fusion reactor relevant materials on exposure to fusion grade plasma in plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Niranjan, Ram, E-mail: niranjan@barc.gov.in [Applied Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Rout, R.K.; Srivastava, R. [Applied Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Chakravarthy, Y. [Laser and Plasma Technology Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Mishra, P. [Materials Processing Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Kaushik, T.C.; Gupta, Satish C. [Applied Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2015-11-15

    Graphical abstract: - Highlights: • Exposure of materials (W, Ni, SS, Mo and Cu) to fusion plasma in a plasma focus device. • The erosion and the formations of blisters, pores, craters, micro-cracks after irradiation. • The structural phase transformation in the SS sample after irradiation. • The surface layer alloying of the samples with the plasma focus anode material. - Abstract: An 11.5 kJ plasma focus (PF) device was used here to irradiate materials with fusion grade plasma. The surface modifications of different materials (W, Ni, stainless steel, Mo and Cu) were investigated using various available techniques. The prominent features observed through the scanning electron microscope on the sample surfaces were erosions, cracks, blisters and craters after irradiations. The surface roughness of the samples increased multifold after exposure as measured by the surface profilometer. The X-ray diffraction analysis indicated the changes in the microstructures and the structural phase transformation in surface layers of the samples. We observed change in volumes of austenite and ferrite phases in the stainless steel sample. The energy dispersive X-ray spectroscopic analysis suggested alloying of the surface layer of the samples with elements of the PF anode. We report here the comparative analysis of the surface damages of materials with different physical, thermal and mechanical properties. The investigations will be useful to understand the behavior of the perspective materials for future fusion reactors (either in pure form or in alloy) over the long operations.

  19. A two-dimensionally focusing, quasi-optical antenna for millimeter-wave scattering in plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Idehara, T.; Tatsukawa, T. (Faculty of Engineering, Fukui University, Fukui 910, Japan (JP)); Brand, G.F.; Fekete, P.W.; Moore, K.J. (School of Physics, University of Sydney, NSW 2006 (Australia))

    1990-06-01

    A two-dimensionally focusing, quasi-optical antenna having one elliptical reflector and one parabolic reflector has been built for use with a tunable gyrotron in order to carry out millimeter-wave scattering measurements on the TORTUS tokamak plasma at the University of Sydney. The advantages of this antenna are the following: (1) The elliptical reflector focuses the radiation beam in the toroidal direction, while the parabolic reflector focuses in the direction of major radius. This gives excellent two-dimensional focusing in the plasma region, and consequently excellent spatial resolution. (2) The focal point can be easily swept along the direction of major radius in the whole plasma region, simply by changing the angle of the parabolic reflector by a small amount. These features have been demonstrated experimentally using the tunable gyrotron source, GYROTRON III, and in computations of the radiated fields.

  20. Description of plasma focus current sheath as the Turner relaxed state of a Hall magnetofluid

    Science.gov (United States)

    Auluck, S. K. H.

    2009-12-01

    The central mystery of plasma focus research is the two orders-of-magnitude-higher-than-thermal fusion reaction rate and the fact that both the space-resolved neutron spectra and space-resolved reaction proton spectra show features which can be ascribed only to a rotational motion of the center-of-mass of the reacting deuteron population. It has been suggested earlier [S. K. H. Auluck, IEEE Trans. Plasma Sci. 25, 37 (1997)] that this and other experimental observations can be consistently explained in terms of a hypothesis involving rotation of the current carrying plasma annulus behind the imploding gas-dynamic shock. Such rotation (more generally, mass flow) is an in-built feature of relaxed state of a two-fluid plasma [R. N. Sudan, Phys. Rev. Lett. 42, 1277 (1979)]. Relaxation in the "Hall magnetofluid" approximation, in which the generalized Ohm's law includes the Hall effect term and the magnetic convection term but omits the contributions to the electric field from resistive dissipation, electron pressure gradient, thermoelectric effect, electron inertia, etc., has been extensively studied by many authors. In the present paper, Turner's [IEEE Trans. Plasma Sci. PS-14, 849 (1986)] degenerate solution for the relaxed state of the Hall magnetohydrodynamic plasma has been adapted to the case of an infinitely long annular current carrying plasma, a tractable idealization of the current sheath of a plasma focus. The resulting model is consistent with experimental values of ion kinetic energy and observation of predominantly radially directed neutron emission in good shots.

  1. Diagnostic systems for the nuclear fusion and plasma research in the PF-24 plasma focus laboratory at the IFJ PAN

    Directory of Open Access Journals (Sweden)

    Marciniak Łukasz

    2016-12-01

    Full Text Available This paper presents a set of diagnostics dedicated to PF-24 - new medium size - plasma focus (PF device built and operated at the Institute of Nuclear Physics Polish Academy of Sciences (IFJ PAN. The PF-24 can operate at energy level up to 93 kJ and charging voltage up to 40 kV. Each condenser is connected with a specially designed spark gap with a very small jitter, which ensures a high effi ciency and a low current rise time. The working parameters of PF-24 generator make it a suitable tool for testing new detection systems to be used in fusion research. Four types of such detection systems are presented in this article: three diagnostic systems used to measure electric quantities (Rogowski coil, magnetic probe, capacitance probe, neutron counter based on beryllium activation, fast neutron pinhole camera based on small-area BCF-12 plastic scintillation detectors and high-speed four-frame soft X-ray camera with microchannel plate.

  2. On the Self-Focusing of Whistler Waves in a Radial Inhomogeneous Plasma

    DEFF Research Database (Denmark)

    Balmashnov, A. A.

    1980-01-01

    The process of whistler wave self-focusing is experimentally investigated. It was found that a whistler wave propagating along the plasma column with a density crest excites a longitudinal wave of the same frequency propagating across the external magnetic field. The amplitude modulation...... of the latter wave is accompanied by a density modification, which leads to trapping of the whistler wave in a density trough in the center of the plasma column....

  3. Emerging treatments in type 2 diabetes: focus on canagliflozin

    Science.gov (United States)

    Rosiak, Marek; Grzeszczak, Susanna; Kosior, Dariusz A; Postuła, Marek

    2014-01-01

    Type 2 diabetes mellitus (T2DM) is a prevalent metabolic disorder, which affects more than 300 million people globally. The common effect of uncontrolled diabetes is the state of hyperglycemia, which results from beta-cell dysfunction as well as insulin resistance, which is accompanied with microvascular and macrovascular complications. As hyperglycemia defines diabetes, glycemic control is fundamental to the management of diabetes. Sodium glucose co-transporter 2 inhibitors (SGLT2) are a new group of oral antidiabetic medications that act by blocking the reabsorption of glucose, causing it to be excreted in the urine. Canagliflozin was the first SGLT2 inhibitor to be approved in the US by the Food and Drug Administration for the treatment and control of T2DM and on September 19, 2013, the Committee for Medicinal Products for Human Use of the European Medicines Agency adopted a positive opinion, recommending the granting of a marketing authorization for the medicinal product Invokana®. Canagliflozin is a SGLT2 inhibitor, which acts upon the proximal tubules of the kidneys and reduces the renal threshold for glucose. It is highly selective, binding 250 times more potently to SGLT2 than sodium glucose co-transporter 1 inhibitor. This action allows a higher amount of glucose to be excreted within the urine, causing the patient’s plasma glucose level to be decreased and indirectly causing weight loss. Among the most common adverse events are hypoglycemia, headache, nausea, female genital and urinary tract infections, nasopharyngitis, and transient postural dizziness. Given its high efficacy in reducing hyperglycemia and good safety profile as either monotherapy or an add-on treatment to metformin, sulfonylureas, or insulin, canagliflozin seems to be a promising antihyperglycemic drug. Nevertheless, further large-scale and long-term studies should be conducted to evaluate the impact of canagliflozin on cardiovascular risk in T2DM patients. PMID:25187722

  4. Low Temperature Plasmas Generated and Sustained Indefinitely Using a Focused Microwave Beam

    Science.gov (United States)

    Reid, Remington; Hoff, Brad; Lepell, Paul; AFRL Team

    2016-10-01

    The Air Force Research Laboratory has constructed a device that can initiate a plasma discharge in a focused microwave beam and sustain it indefinitely. A 10 kW, 4.5 GHz beam is passed through a vacuum chamber outfitted with pressure windows that are transparent to 4.5 GHz radiation. The pressure windows are large enough in diameter to prevent any interactions between the beam and the metallic chamber. The entire experiment is housed inside an anechoic chamber to minimize reflections. This novel plasma source generates low temperature, low density plasmas that have no contact with the walls which minimizes contamination and sheath formation.

  5. Fine structure of modal focusing effect in a three dimensional plasma-sheath-lens formed by disk electrodes

    DEFF Research Database (Denmark)

    Stamate, Eugen; Yamaguchi, Masahito

    2015-01-01

    Modal and discrete focusing effects associated with three-dimensional plasma-sheath-lenses show promising potential for applications in ion beam extraction, mass spectrometry, plasma diagnostics and for basic studies of plasma sheath. The ion focusing properties can be adjusted by controlling the...

  6. OPTIMISATION OF NEON SXR (SOFT X-RAY YIELD OF THE INTI PLASMA FOCUS MACHINE AT 12 kV

    Directory of Open Access Journals (Sweden)

    A.R.J.A. FEDERICO

    2015-02-01

    Full Text Available The INTI plasma focus machine is a 3 kJ Mather type plasma focus machine,powered by a single Maxwell capacitor. The system produces remarkable consistent focusing action in neon, making it a suitable source for the production of high energy photons, electrons, ions and neon soft x-rays (SXR [1, 2]. The aim of this paper is to optimise the neon SXR yield of the INTI plasma focus machine operated at 12 kV by parametrically, changing the anode dimensions (radius and length using the Lee Model Code (version RADPFV5.15dd. Results of the optimisation procedures resulted in a neon SXR yield of 6.47 J at 2.5 torr and 12 kV, with a shorter length and a fatter anode radius of 7.9 cm and 1.2 cm respectively. This gives an improvement in the neon SXR yield of 40% when compares to neon SXR yield of 2.74 J at 2.5 torr 12 kV with the present configurations.

  7. Emerging treatments in type 2 diabetes: focus on canagliflozin

    Directory of Open Access Journals (Sweden)

    Rosiak M

    2014-08-01

    Full Text Available Marek Rosiak,1,2 Susanna Grzeszczak,2 Dariusz A Kosior,2,3 Marek Postuła1,2 1Department of Cardiology and Hypertension, Central Clinical Hospital, the Ministry of the Interior, Warsaw, Poland; 2Department of Experimental and Clinical Pharmacology, Medical University of Warsaw, Poland; 3Mossakowski Medical Research Centre, Polish Academy of Sciences, Warsaw, Poland Abstract: Type 2 diabetes mellitus (T2DM is a prevalent metabolic disorder, which affects more than 300 million people globally. The common effect of uncontrolled diabetes is the state of hyperglycemia, which results from beta-cell dysfunction as well as insulin resistance, which is accompanied with microvascular and macrovascular complications. As hyperglycemia defines diabetes, glycemic control is fundamental to the management of diabetes. Sodium glucose co-transporter 2 inhibitors (SGLT2 are a new group of oral antidiabetic medications that act by blocking the reabsorption of glucose, causing it to be excreted in the urine. Canagliflozin was the first SGLT2 inhibitor to be approved in the US by the Food and Drug Administration for the treatment and control of T2DM and on September 19, 2013, the Committee for Medicinal Products for Human Use of the European Medicines Agency adopted a positive opinion, recommending the granting of a marketing authorization for the medicinal product Invokana®. Canagliflozin is a SGLT2 inhibitor, which acts upon the proximal tubules of the kidneys and reduces the renal threshold for glucose. It is highly selective, binding 250 times more potently to SGLT2 than sodium glucose co-transporter 1 inhibitor. This action allows a higher amount of glucose to be excreted within the urine, causing the patient's plasma glucose level to be decreased and indirectly causing weight loss. Among the most common adverse events are hypoglycemia, headache, nausea, female genital and urinary tract infections, nasopharyngitis, and transient postural dizziness. Given its

  8. Plasma follistatin is elevated in patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Hansen, J; Rinnov, Anders Rasmussen; Krogh-Madsen, Rikke

    2013-01-01

    Plasma follistatin is elevated in patients with low-grade inflammation and insulin resistance as observed with polycystic ovary syndrome. In the present study, we evaluated plasma follistatin in patients with type 2 diabetes characterised by low-grade inflammation and assessed the acute effects o...

  9. Intricate Plasma-Scattered Images and Spectra of Focused Femtosecond Laser Pulses

    Science.gov (United States)

    Ooi, C. H. Raymond; Talib, Md. Ridzuan

    2016-08-01

    We report on some interesting phenomena in the focusing and scattering of femtosecond laser pulses in free space that provide insights on intense laser plasma interactions. The scattered image in the far field is analyzed and the connection with the observed structure of the plasma at the focus is discussed. We explain the physical mechanisms behind the changes in the colorful and intricate image formed by scattering from the plasma for different compressions, as well as orientations of plano-convex lens. The laser power does not show significant effect on the images. The pulse repetition rate above 500 Hz can affect the image through slow dynamics The spectrum of each color in the image shows oscillatory peaks due to interference of delayed pulse that correlate with the plasma length. Spectral lines of atomic species are identified and new peaks are observed through the white light emitted by the plasma spot. We find that an Ar gas jet can brighten the white light of the plasma spot and produce high resolution spectral peaks. The intricate image is found to be extremely sensitive and this is useful for applications in sensing microscale objects.

  10. Time-resolved spectra of dense plasma focus using spectrometer, streak camera, and CCD combination

    Energy Technology Data Exchange (ETDEWEB)

    Goldin, F. J. [Livermore Operations, National Security Technologies, LLC, Livermore, California 94550 (United States); Meehan, B. T.; Hagen, E. C. [North Las Vegas Facility, National Security Technologies, LLC, North Las Vegas, Nevada 89030 (United States); Wilkins, P. R. [Lawrence Livermore National Laboratories, Livermore, California 94550 (United States)

    2010-10-15

    A time-resolving spectrographic instrument has been assembled with the primary components of a spectrometer, image-converting streak camera, and CCD recording camera, for the primary purpose of diagnosing highly dynamic plasmas. A collection lens defines the sampled region and couples light from the plasma into a step index, multimode fiber which leads to the spectrometer. The output spectrum is focused onto the photocathode of the streak camera, the output of which is proximity-coupled to the CCD. The spectrometer configuration is essentially Czerny-Turner, but off-the-shelf Nikon refraction lenses, rather than mirrors, are used for practicality and flexibility. Only recently assembled, the instrument requires significant refinement, but has now taken data on both bridge wire and dense plasma focus experiments.

  11. Time-Resolved Spectra of Dense Plasma Focus Using Spectrometer, Streak Camera, CCD Combination

    Energy Technology Data Exchange (ETDEWEB)

    F. J. Goldin, B. T. Meehan, E. C. Hagen, P. R. Wilkins

    2010-10-01

    A time-resolving spectrographic instrument has been assembled with the primary components of a spectrometer, image-converting streak camera, and CCD recording camera, for the primary purpose of diagnosing highly dynamic plasmas. A collection lens defines the sampled region and couples light from the plasma into a step index, multimode fiber which leads to the spectrometer. The output spectrum is focused onto the photocathode of the streak camera, the output of which is proximity-coupled to the CCD. The spectrometer configuration is essentially Czerny–Turner, but off-the-shelf Nikon refraction lenses, rather than mirrors, are used for practicality and flexibility. Only recently assembled, the instrument requires significant refinement, but has now taken data on both bridge wire and dense plasma focus experiments.

  12. Self-Focusing/Defocusing of Chirped Gaussian Laser Beam in Collisional Plasma with Linear Absorption

    Science.gov (United States)

    Wani, Manzoor Ahmad; Kant, Niti

    2016-09-01

    This paper presents an investigation on the self-focusing/defocusing of chirped Gaussian laser beam in collisional plasma with linear absorption. We have derived the differential equation for the beam width parameter by using WKB and paraxial approximations and solved it numerically. The effect of chirp and other laser plasma parameters is seen on the behavior of beam width parameter with dimensionless distance of propagation. The results are discussed and presented graphically. Our simulation results show that the amplitude of oscillations decreases with the distance of propagation. Due to collisional frequency, the laser beam shows fast divergence which can be minimized by the introduction of chirp parameter. The chirp decreases the effect of defocusing and increases the ability of self-focusing of laser beam in collisional plasma. Supported by a financial grant from CSIR, New Delhi, India, under Project No. 03(1277)/13/EMR-II

  13. Ion beam extraction from a matrix ECR plasma source by discrete ion-focusing effect

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, Mihai

    2010-01-01

    Positive or negative ion beams extracted from plasma are used in a large variety of surface functionalization techniques such as implantation, etching, surface activation, passivation or oxidation. Of particular importance is the surface treatment of materials sensitive to direct plasma exposure...... due to high heath fluxes, the controllability of the ion incidence angle, and charge accumulation when treating insulating materials. Despite of a large variety of plasma sources available for ion beam extraction, there is a clear need for new extraction mechanisms that can make available ion beams...... with high current densities that can treat surfaces placed adjacent to the extraction region. This work introduces a new phenomenology for ion beam extraction using the discrete ion-focusing effect associated with three-dimensional plasma-sheath-lenses [1, 2]. Experiments are performed in a matrix...

  14. High-throughput blood cell focusing and plasma isolation using spiral inertial microfluidic devices.

    Science.gov (United States)

    Xiang, Nan; Ni, Zhonghua

    2015-12-01

    Herein, we explored the blood cell focusing and plasma isolation using a spiral inertial microfluidic device. First, the flow-rate and concentration effects on the migration dynamics of blood cells were systematically investigated to uncover the focusing mechanisms and steric crowding effects of cells in Dean-coupled inertial flows. A novel phenomenon that the focusing status of discoid red blood cells (RBCs) changes according to the channel height was discovered. These experimental data may provide valuable insights for the high-throughput processing of blood samples using inertial microfluidics. On the basis of the improved understandings on blood cell focusing, efficient isolation of plasma from whole blood with a 20-fold dilution was achieved at a throughput up to 700 μl/min. The purity of the isolated blood plasma was close to 100 %, and the plasma yield was calculated to be 38.5 %. As compared with previously-reported devices, our spiral inertial microfluidic device provides a balanced overall performance, and has overriding advantages in terms of processing throughput and operating efficiency.

  15. Self-Focusing of Hermite-Cosh-Gaussian Laser Beams in Plasma under Density Transition

    Directory of Open Access Journals (Sweden)

    Manzoor Ahmad Wani

    2014-01-01

    Full Text Available Self-focusing of Hermite-Cosh-Gaussian (HChG laser beam in plasma under density transition has been discussed here. The field distribution in the medium is expressed in terms of beam-width parameters and decentered parameter. The differential equations for the beam-width parameters are established by a parabolic wave equation approach under paraxial approximation. To overcome the defocusing, localized upward plasma density ramp is considered, so that the laser beam is focused on a small spot size. Plasma density ramp plays an important role in reducing the defocusing effect and maintaining the focal spot size up to several Rayleigh lengths. To discuss the nature of self-focusing, the behaviour of beam-width parameters with dimensionless distance of propagation for various values of decentered parameters is examined by numerical estimates. The results are presented graphically and the effect of plasma density ramp and decentered parameter on self-focusing of the beams has been discussed.

  16. Seeding the m = 0 instability in dense plasma focus Z-pinches with a hollow anode

    CERN Document Server

    Liu, J X; McMahon, M; Tummel, K; Cooper, C; Higginson, D; Shaw, B; Povilus, A; Link, A; Schmidt, A

    2016-01-01

    The dense plasma focus (DPF) is a classic Z-pinch plasma device that has been studied for decades as a radiation source. The formation of the m = 0 plasma instability during the compression phase is linked to the generation of high-energy charged particle beams, which, when operated in deuterium, lead to beam-target fusion reactions and the generation of neutron yield. In this paper, we present a technique of seeding the m = 0 instability by employing a hollow in the anode. As the plasma sheath moves along the anode's hollow structure, a low density perturbation is formed and this creates a non-uniform plasma column which is highly unstable. Dynamics of the low density perturbation and preferential seeding of the m = 0 instability were studied in detail with fully kinetic plasma simulations performed in the Large Scale Plasma particle-in-cell code as well as with a simple snowplow model. The simulations showed that by employing an anode geometry with appropriate inner hollow radius, the neutron yield of the D...

  17. Comparative study of X-ray emission from plasma focus relative to different preionization schemes

    Science.gov (United States)

    Ahmad, S.; Qayyum, A.; Hassan, M.; Zakaullah, M.

    2017-07-01

    A 2.7-kJ Mather-type plasma focus has been investigated for X-ray emission with preionization produced by an α-source, a β-source, and a shunt resistor. Time-resolved and time integrated measurements are carried out using a PIN-diode-based X-ray spectrometer and pinhole camera. The β-source (28Ni63) assisted preionization enhances the X-ray emission up to 25%, while preionization induced by depleted uranium (92U238) increases both Cu-Kα and total X-ray yield of about 100%. The preionization caused by the optimum shunt resistor enhances the Cu-Kα and total X-ray yield of about 53%. It is found that preionization also broadens the working pressure range for the high X-ray yield and improves the shot-to-shot reproducibility of the system. Pinhole images reveal that the X-ray emission from the anode tip is dominant owing to impact of electron bombardment, while the X-ray emission from hot spots is also visible.

  18. Submicron focusing of XUV radiation from a laser plasma source using a multilayer Laue lens

    Science.gov (United States)

    Reese, M.; Schäfer, B.; Großmann, P.; Bayer, A.; Mann, K.; Liese, T.; Krebs, H. U.

    2011-01-01

    The focusing properties of a one-dimensional multilayer Laue lens (MLL) were investigated using monochromatic soft X-ray radiation from a table-top, laser-produced plasma source. The MLL was fabricated by a focused ion beam (FIB) structuring of pulsed laser deposited ZrO2/Ti multilayers. This novel method offers the potential to overcome limitations encountered in electron lithographic processes. Utilizing this multilayer Laue lens, a line focus of XUV radiation from a laser-induced plasma in a nitrogen gas puff target could be generated. The evaluated focal length is close to the designed value of 220 μm for the measurement wavelength of 2.88 nm. Divergence angle and beam waist diameter are measured by a moving knife edge and a far-field experiment, determining all relevant second-order moments based beam parameters. The waist diameter has been found to be approximately 370 nm (FWHM).

  19. Stark Broadening Analysis Using Optical Spectroscopy of the Dense Plasma Focus

    Science.gov (United States)

    Ross, Patrick; Bennett, Nikki; Dutra, Eric; Hagen, E. Chris; Hsu, Scott; Hunt, Gene; Koch, Jeff; Waltman, Tom; NSTec DPF Team

    2015-11-01

    To aid in validating numerical modeling of MA-class dense plasma focus (DPF) devices, spectroscopic measurements of the Gemini Dense Plasma Focus (DPF) were performed using deuterium and deuterium/dopant (argon/krypton) gas. The spectroscopic measurements were made using a fiber-coupled spectrometer and streak camera. Stark line-broadening analysis was applied to the deuterium beta emission (486 nm) in the region near the breakdown of the plasma and during the run-down and run-in phases of the plasma evolution. Densities in the range of 1e17 to low 1e18 cm-3 were obtained. These values are in agreement with models of the DPF performed using the LSP code. The spectra also show a rise and fall with time, indicative of the plasma sheath passing by the view port. Impurity features were also identified in the spectra which grew in intensity as the gas inside the DPF was discharged repeatedly without cycling. Implications of this impurity increase for D-T discharges (without fresh gas fills between every discharge) will be discussed. This work was done by National Security Technologies, LLC, under Contract No. DE-AC52-06NA25946, and by Los Alamos National Laboratory, under Contract no. DE-AC52-06NA25396 with the U.S. Department of Energy. DOE/NV/25946-2515.

  20. Imperative function of electron beams in low-energy plasma focus device

    Indian Academy of Sciences (India)

    M Z Khan; L K Lim; S L Yap; C S Wong

    2015-12-01

    A 2.2 kJ plasma focus device was analysed as an electron beam and an X-ray source that operates with argon gas refilled at a specific pressure. Time-resolved X-ray signals were observed using an array of PIN diode detectors, and the electron beam energy was detected using a scintillator-assisted photomultiplier tube. The resultant X-rays were investigated by plasma focus discharge for pressures ranging from 1.5 mbar to 2.0 mbar. This range corresponded to the significant values of X-ray yields and electron beam energies from the argon plasma. The electron temperature of argon plasma at an optimum pressure range was achieved by an indirect method using five-channel BPX65 PIN diodes of aluminum foils with different thicknesses. X-ray yield, electron beam energy, and electron temperature of argon plasma were achieved at 1.5–2.0 mbar because of the strong bombardment of the energetic electron beam.

  1. Developing a plasma focus research training system for the fusion energy age

    Science.gov (United States)

    Lee, S.

    2014-08-01

    The 3 kJ UNU/ICTP Plasma Focus Facility is the most significant device associated with the AAAPT (Asian African Association for Plasma Training). In original and modified/upgraded form it has trained generations of plasma focus (PF) researchers internationally, producing many PhD theses and peer-reviewed papers. The Lee Model code was developed for the design of this PF. This code has evolved to cover all PF machines for design, interpretation and optimization, for derivation of radiation scaling laws; and to provide insights into yield scaling limitations, radiative collapse, speed-enhanced and current-stepped PF variants. As example of fresh perspectives derivable from this code, this paper presents new results on energy transfers of the axial and radial phases of generalized PF devices. As the world moves inexorably towards the Fusion Energy Age it becomes ever more important to train plasma fusion researchers. A recent workshop in Nepal shows that demand for such training continues. Even commercial project development consultants are showing interest. We propose that the AAAPT-proven research package be upgraded, by modernizing the small PF for extreme modes of operation, switchable from the typical strong-focus mode to a slow-mode which barely pinches, thus producing a larger, more uniform plasma stream with superior deposition properties. Such a small device would be cost-effective and easily duplicated, and have the versatility of a range of experiments from intense multi-radiation generation and target damage studies to superior advanced-materials deposition. The complementary code is used to reference experiments up to the largest existing machine. This is ideal for studying machine limitations and scaling laws and to suggest new experiments. Such a modernized versatile PF machine complemented by the universally versatile code would extend the utility of the PF experience; so that AAAPT continues to provide leadership in pulsed plasma research training in

  2. Modelling of the internal dynamics and density in a tens of joules plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Marquez, Ariel [CNEA and Instituto Balseiro, 8402 Bariloche (Argentina); Gonzalez, Jose [INVAP-CONICET and Instituto Balseiro, 8402 Bariloche, Argentina. (Argentina); Tarifeno-Saldivia, Ariel; Pavez, Cristian; Soto, Leopoldo [CCHEN, Comision Chilena de Energia Nuclear, Casilla 188-D, Santiago (Chile); Center for Research and Applications in Plasma Physics and Pulsed Power, P4 (Chile); Clausse, Alejandro [CNEA-CONICET and Universidad Nacional del Centro, 7000 Tandil (Argentina)

    2012-01-15

    Using MHD theory, coupled differential equations were generated using a lumped parameter model to describe the internal behaviour of the pinch compression phase in plasma focus discharges. In order to provide these equations with appropriate initial conditions, the modelling of previous phases was included by describing the plasma sheath as planar shockwaves. The equations were solved numerically, and the results were contrasted against experimental measurements performed on the device PF-50J. The model is able to predict satisfactorily the timing and the radial electron density profile at the maximum compression.

  3. Relativistic self-focusing of intense laser beam in thermal collisionless quantum plasma with ramped density profile

    Science.gov (United States)

    Zare, S.; Yazdani, E.; Rezaee, S.; Anvari, A.; Sadighi-Bonabi, R.

    2015-04-01

    Propagation of a Gaussian x-ray laser beam has been analyzed in collisionless thermal quantum plasma with considering a ramped density profile. In this density profile due to the increase in the plasma density, an earlier and stronger self-focusing effect is noticed where the beam width oscillates with higher frequency and less amplitude. Moreover, the effect of the density profile slope and the initial plasma density on the laser propagation has been studied. It is found that, by increasing the initial density and the ramp slope, the laser beam focuses faster with less oscillation amplitude, smaller laser spot size and more oscillations. Furthermore, a comparison is made among the laser self-focusing in thermal quantum plasma, cold quantum plasma and classical plasma. It is realized that the laser self-focusing in the quantum plasma becomes stronger in comparison with the classical regime.

  4. Dense Plasma Focus Z-pinches for High Gradient Particle Acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Tang, V; Adams, M L; Rusnak, B

    2009-07-24

    The final Z-pinch stage of a Dense Plasma Focus (DPF) could be used as a simple, compact, and potentially rugged plasma-based high-gradient accelerator with fields at the 100 MV/m level. In this paper we review previously published experimental beam data that indicate the feasibility of such an DPF-based accelerator, qualitatively discuss the physical acceleration processes in terms of the induced voltages, and as a starting point examine the DPF acceleration potential by numerically applying a self-consistent DPF system model that includes the induced voltage from both macroscopic and instability driven plasma dynamics. Applications to the remote detection of high explosives and a multi-staged acceleration concept are briefly discussed.

  5. Ponderomotive self-focusing of Gaussian laser beam in warm collisional plasma

    Energy Technology Data Exchange (ETDEWEB)

    Jafari Milani, M. R., E-mail: mrj.milani@gmail.com [Plasma Physics Research School, Tehran (Iran, Islamic Republic of); Department of Energy Engineering and Physics, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Niknam, A. R., E-mail: a-niknam@sbu.ac.ir [Laser and Plasma Research Institute, Shahid Beheshti University, G.C., Tehran (Iran, Islamic Republic of); Farahbod, A. H. [Plasma Physics Research School, Tehran (Iran, Islamic Republic of)

    2014-06-15

    The propagation characteristics of a Gaussian laser beam through warm collisional plasma are investigated by considering the ponderomotive force nonlinearity and the complex eikonal function. By introducing the dielectric permittivity of warm unmagnetized plasma and using the WKB and paraxial ray approximations, the coupled differential equations defining the variations of laser beam parameters are obtained and solved numerically. Effects of laser and plasma parameters such as the collision frequency, the initial laser intensity and its spot size on the beam width parameter and the axis laser intensity distribution are analyzed. It is shown that, self-focusing of the laser beam takes place faster by increasing the collision frequency and initial laser spot size and then after some distance propagation the laser beam abruptly loses its initial diameter and vastly diverges. Furthermore, the modified electron density distribution is obtained and the collision frequency effect on this distribution is studied.

  6. Study of soft X-ray emission during wire array implosion under plasma focus conditions at the PF-3 facility

    Energy Technology Data Exchange (ETDEWEB)

    Dan’ko, S. A. [National Research Centre Kurchatov Institute (Russian Federation); Mitrofanov, K. N., E-mail: mitrofan@triniti.ru [Troitsk Institute for Innovation and Fusion Research (Russian Federation); Krauz, V. I.; Myalton, V. V.; Zhuzhunashvili, A. I.; Vinogradov, V. P.; Kharrasov, A. M.; Anan’ev, S. S.; Vinogradova, Yu. V.; Kalinin, Yu. G. [National Research Centre Kurchatov Institute (Russian Federation)

    2015-11-15

    Results of measurements of soft X-ray emission with photon energies of <1 keV under conditions of a plasma focus (PF) experiment are presented. The experiments were carried out at the world’s largest PF device—the PF-3 Filippov-type facility (I ⩽ 3 MA, T/4 ≈ 15–20 µs, W{sub 0} ⩽ 3 MJ). X-ray emission from both a discharge in pure neon and with a tungsten wire array placed on the axis of the discharge chamber was detected. The wire array imploded under the action of the electric current intercepted from the plasma current sheath of the PF discharge in neon. The measured soft X-ray powers from a conventional PF discharge in gas and a PF discharge in the presence of a wire array were compared for the first time.

  7. Application of plasma-polymerized films for isoelectric focusing of proteins in a capillary electrophoresis chip.

    Science.gov (United States)

    Tsai, Shuo-Wen; Loughran, Michael; Hiratsuka, Atsunori; Yano, Kazuyoshi; Karube, Isao

    2003-03-01

    The first use of plasma polymerization technique to modify the surface of a glass chip for capillary isoelectric focusing (cIEF) of different proteins is reported. The electrophoresis separation channel was machined in Tempax glass chips with length 70 mm, 300 microm width and 100 microm depth. Acetonitrile and hexamethyldisiloxane monomers were used for plasma polymerization. In each case 100 nm plasma polymer films were coated onto the chip surface to reduce protein wall adsorption and minimize the electroosmotic flow. Applied voltages of 1000 V, 2000 V and 3000 V were used to separate mixtures of cytochrome c (pI 9.6), hemoglobin (pI 7.0) and phycocyanin (pI 4.65). Reproducible isoelectric focusing of each pI marker protein was observed in different coated capillaries at increasing concentration 2.22-5 microg microL(-1). Modification of the glass capillary with hydrophobic HMDS plasma polymerized films enabled rapid cIEF within 3 min. The separation efficiency of cytochrome c and phycocyanin in both acrylamide and HMDS coated capillaries corresponded to a plate number of 19600 which compares favourably with capillary electrophoresis of neurotransmitters with amperometric detection.

  8. Statistical characterization of the reproducibility of neutron emission of small plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Tarifeno-Saldivia, Ariel; Soto, Leopoldo [Comision Chilena de Energia Nuclear (CCHEN), Casilla 188-D, Santiago (Chile); Center for Research and Applications in Plasma Physics and Pulsed Power, P4 (Chile) and Departamento de Ciencias Fisicas, Universidad Andres Bello, Republica 220, Santiago (Chile)

    2012-09-15

    The purpose of this work is to discuss the techniques related to the detection of fast pulsed neutrons produced in plasma focus (PF) devices, the statistical analysis of the corresponding data, and the methodologies for evaluation of the device performance in low emission neutron sources. A general mathematical framework is presented for the assessment of the reproducibility of the neutron emission of small PF devices given the shot-to-shot distribution and detector efficiency. The effect on the reproducibility in case of using two independent detectors is also discussed. The analysis is applied to the neutron emission of the plasma focus device PF-50J operating in repetitive mode (0.1-0.5 Hz and 65 J bank energy).

  9. Advances towards pB11 Fusion with the Dense Plasma Focus

    CERN Document Server

    Lerner, Eric J

    2007-01-01

    The prospects for achieving net energy production with pB11 fuel have recently considerably brightened. Studies have shown that the multi-GG field potentially obtainable with modest dense plasma focus devices have the effect of reducing the flow of energy from the ions to the electrons and thus suppressing bremsstrahlung radiation that cools the plasma. We report here on new simulations that indicate that net energy production may be achievable in high-magnetic-field devices at peak currents as low as 2.3 MA. While these simulations only model the dense plasmoid formed in the focus, new simulation techniques can allow a full particle-in-cell simulation of DPF functioning over the wide range of time and space scales needed. Such simulations will be of great value in the next round of experiments that will use pB11 fuel.

  10. X-ray emission from a small 2 kJ plasma focus

    Science.gov (United States)

    Beg, F. N.; Ross, I.; Dangor, A. E.

    1997-05-01

    We report on a study of a 2 kJ, 200 kA plasma focus device as an x-ray source. The x-ray yield from a number of pure gases, deuterium, nitrogen, neon, argon, and xenon, was measured as a function of pressure. X-ray emission is mainly due to line radiation. Maximum x-ray yield of 12.5 J obtained for neon. At lower pressures, electron beams are generated which play an important role.

  11. Numerical Analysis of Amirkabir Plasma Focus (APF) Device for Neon and Argon Gases

    Science.gov (United States)

    Niknam Sharak, M.; Goudarzi, S.; Raeisdana, A.; Jafarabadi, M.

    2013-04-01

    In this paper the experimental results in different working conditions in Amirkabir Plasma Focus (APF) Device have been compared with the numerical results of a two-dimensional simulation code based on Lee's model. The experiments were done with pure Neon and Argon as operating gases over a wide range of working conditions (gas pressures and discharge voltages). It is observed that by a proper choice for values of the efficiency factors, comparison between numerical and experimental results shows a good agreement.

  12. High-Energy Ion Acceleration Mechanisms in a Dense Plasma Focus Z-Pinch

    Science.gov (United States)

    Higginson, D. P.; Link, A.; Schmidt, A.; Welch, D.

    2016-10-01

    The compression of a Z-pinch plasma, specifically in a dense plasma focus (DPF), is known to accelerate high-energy electrons, ions and, if using fusion-reactant ions (e.g. D, T), neutrons. The acceleration of particles is known to coincide with the peak constriction of the pinch, however, the exact physical mechanism responsible for the acceleration remains an area of debate and uncertainty. Recent work has suggested that this acceleration is linked to the growth of an m =0 (sausage) instability that evacuates a region of low-density, highly-magnetized plasma and creates a strong (>MV/cm) electric field. Using the fully kinetic particle-in-cell code LSP in 2D-3V, we simulate the compression of a 2 MA, 35 kV DPF plasma and investigate in detail the formation of the electric field. The electric field is found to be predominantly in the axial direction and driven via charge-separation effects related to the resistivity of the kinetic plasma. The strong electric and magnetic fields are shown to induce non-Maxwellian distributions in both the ions and electrons and lead to the acceleration of high-energy tails. We compare the results in the kinetic simulations to assumptions of magnetohydrodynamics (MHD). Prepared by LLNL under Contract DE-AC52-07NA27344.

  13. Repetitive tabletop plasma focus to produce a tunable damage factor on materials for fusion reactors

    Science.gov (United States)

    Soto, Leopoldo; Pavez, Cristian; Inestrosa-Izurieta, Maria Jose; Moreno, Jose; Davis, Sergio; Bora, Biswajit; Avaria, Gonzalo; Jain, Jalaj; Altamirano, Luis; Panizo, Miguel; Gonzalez, Raquel; Rivera, Antonio

    2016-10-01

    Future thermonuclear reactors, both magnetic and inertial confinement approaches, need materials capable of withstanding the extreme radiation and heat loads expected from high repetition rate plasma. A damage factor (F = qτ1/2) in the order of 104 (W/cm2) s1/2 is expected. The axial plasma dynamics after the pinch in a tabletop plasma focus of hundred joules, PF-400J, was characterized by means of pulsed optical refractive diagnostics. The energy, interaction time and power flux of the plasma burst interacting with targets was obtained. Results show a high dependence of the damage factor with the distance from the anode top where the sample is located. A tunable damage factor in the range 10- 105(W/cm2) s1/2 can be obtained. At present the PF-400J operating at 0.077 Hz is being used to study the effects of fusion-relevant pulses on material target, including nanostructured materials. A new tabletop device to be operated up to 1Hz including tunable damage factor has been designed and is being constructed, thus thousand cumulative shots on materials could be obtained in few minutes. The scaling of the damage factor for plasma foci operating at different energies is discussed. Supported by CONICYT: PIA ACT-1115, PAI 79130026.

  14. Comparison of measured and computed radial trajectories of plasma focus devices UMDPF1 and UMDPF0

    Energy Technology Data Exchange (ETDEWEB)

    Lim, L. H.; Yap, S. L., E-mail: yapsl@um.edu.my; Lim, L. K.; Lee, M. C.; Poh, H. S.; Ma, J. [Plasma Technology Research Centre, Department of Physics, Faculty of Science, University of Malaya, 50603 Kuala Lumpur (Malaysia); Yap, S. S. [UMPEDAC, University of Malaya, 50603 Kuala Lumpur (Malaysia); Faculty of Engineering, Multimedia University, Cyberjaya, 63100 Selangor (Malaysia); Lee, S. [Plasma Technology Research Centre, Department of Physics, Faculty of Science, University of Malaya, 50603 Kuala Lumpur (Malaysia); INTI International University, 71800 Nilai (Malaysia); Institute for Plasma Focus Studies, 32 Oakpark Drive, Chadstone 3148 (Australia)

    2015-09-15

    In published literature, there has been scant data on radial trajectory of the plasma focus and no comparison of computed with measured radial trajectory. This paper provides the first such comparative study. We compute the trajectories of the inward-moving radial shock and magnetic piston of UMDPF1 plasma focus and compare these with measured data taken from a streak photograph. The comparison shows agreement with the measured radial trajectory in terms of average speeds and general shape of trajectory. This paper also presents the measured trajectory of the radially compressing piston in another machine, the UMDPF0 plasma focus, confirming that the computed radial trajectory also shows similar general agreement. Features of divergence between the computed and measured trajectories, towards the end of the radial compression, are discussed. From the measured radial trajectories, an inference is made that the neutron yield mechanism could not be thermonuclear. A second inference is made regarding the speeds of axial post-pinch shocks, which are recently considered as a useful tool for damage testing of fusion-related wall materials.

  15. Focus on Vitamin D, Inflammation and Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Marcelo Macedo Rogero

    2012-01-01

    Full Text Available The initial observations linking vitamin D to type 2 diabetes in humans came from studies showing that both healthy and diabetic subjects had a seasonal variation of glycemic control. Currently, there is evidence supporting that vitamin D status is important to regulate some pathways related to type 2 diabetes development. Since the activation of inflammatory pathways interferes with normal metabolism and disrupts proper insulin signaling, it is hypothesized that vitamin D could influence glucose homeostasis by modulating inflammatory response. Human studies investigating the impact of vitamin D supplementation on inflammatory biomarkers of subjects with or at high risk of developing type 2 diabetes are scarce and have generated conflicting results. Based on available clinical and epidemiological data, the positive effects of vitamin D seem to be primarily related to its action on insulin secretion and sensitivity and secondary to its action on inflammation. Future studies specifically designed to investigate the role of vitamin D on type 2 diabetes using inflammation as the main outcome are urgently needed in order to provide a more robust link between vitamin D, inflammation and type 2 diabetes.

  16. Use of plasma: clinical indications and types of plasma components in Sweden.

    Science.gov (United States)

    Norda, R; Tynell, E

    2007-12-01

    The use of plasma in Sweden is relatively high compared to other countries in the European Union. An analysis of all transfusion recipients in Orebro county during the whole year 2000 was performed. There were 3159 transfusion recipients of whom 96% had a registered diagnosis and 50% had undergone a "true" operation. Seven hundred and eleven patients (23%) had received plasma. Significantly more operated than nonoperated and more men than women received plasma. The typical plasma recipient was a man undergoing cardiovascular surgery. In Sweden there are two main types of plasma components: fresh frozen (FFP) and nonfrozen liquid plasma stored for up to 14 days, both considered to be clinically equal for most indications. The quality of these components as well as stored thawed FFP has been studied. The major storage effect was cold-induced contact activation and thereby consumption of C1 esterase inhibitor (C1INH) by day 14 in 22%. The citrate content in plasma sustained the overall coagulation function over 14 days. Other studies have shown that the levels of FV and ADAMTS 13 after 14 days remain at 70% or more compared to those for FFP. Since it is immediately available, liquid, nonfrozen or thawed, plasma is of great value in emergencies. Quality criteria for plasma components need to be assessed against evidence based indications and published in guidelines.

  17. Emerging treatments in type 2 diabetes: focus on canagliflozin

    OpenAIRE

    Rosiak M; Grzeszczak S; Kosior DA; Postuła M

    2014-01-01

    Marek Rosiak,1,2 Susanna Grzeszczak,2 Dariusz A Kosior,2,3 Marek Postuła1,2 1Department of Cardiology and Hypertension, Central Clinical Hospital, the Ministry of the Interior, Warsaw, Poland; 2Department of Experimental and Clinical Pharmacology, Medical University of Warsaw, Poland; 3Mossakowski Medical Research Centre, Polish Academy of Sciences, Warsaw, Poland Abstract: Type 2 diabetes mellitus (T2DM) is a prevalent metabolic disorder, which affects more than 300 million people globally...

  18. Characterization of the axial plasma shock in a table top plasma focus after the pinch and its possible application to testing materials for fusion reactors

    Energy Technology Data Exchange (ETDEWEB)

    Soto, Leopoldo, E-mail: lsoto@cchen.cl; Pavez, Cristian; Moreno, José [Comisión Chilena de Energía Nuclear, Casilla 188-D, Santiago (Chile); Centro de Investigación y Aplicaciones en Física de Plasmas y Potencia Pulsada, P" 4, Santiago-Talca (Chile); Departamento de Ciencias Físicas, Facultad de Ciencias Exactas, Universidad Andrés Bello, República 220, Santiago (Chile); Inestrosa-Izurieta, María José [Comisión Chilena de Energía Nuclear, Casilla 188-D, Santiago (Chile); Centro de Investigación y Aplicaciones en Física de Plasmas y Potencia Pulsada, P" 4, Santiago-Talca (Chile); Veloso, Felipe [Instituto de Física, Pontificia Universidad Católica de Chile, Santiago (Chile); Gutiérrez, Gonzalo [Departamento de Física, Facultad de Ciencias, Universidad de Chile, Santiago (Chile); Vergara, Julio [Facultad de Ingeniería, Pontificia Universidad Católica de Chile, Santiago (Chile); Clausse, Alejandro [CNEA-CONICET and Universidad Nacional del Centro, 7000 Tandil (Argentina); Bruzzone, Horacio [CONICET and Universidad de Mar del Plata, Mar del Plata (Argentina); Castillo, Fermín [Instituto de Ciencias Físicas, Universidad Nacional Autónoma de México, Cuernavaca, Morelos (Mexico); and others

    2014-12-15

    The characterization of plasma bursts produced after the pinch phase in a plasma focus of hundreds of joules, using pulsed optical refractive techniques, is presented. A pulsed Nd-YAG laser at 532 nm and 8 ns FWHM pulse duration was used to obtain Schlieren images at different times of the plasma dynamics. The energy, interaction time with a target, and power flux of the plasma burst were assessed, providing useful information for the application of plasma focus devices for studying the effects of fusion-relevant pulses on material targets. In particular, it was found that damage factors on targets of the order of 10{sup 4} (W/cm{sup 2})s{sup 1/2} can be obtained with a small plasma focus operating at hundred joules.

  19. Kinetic Simulations of the Self-Focusing and Dissipation of Finite-Width Electron Plasma Waves

    Energy Technology Data Exchange (ETDEWEB)

    Winjum, B. J. [Univ. of California, Los Angeles, CA (United States); Berger, R. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chapman, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Banks, J. W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brunner, S. [Federal Inst. of Technology, Lausanne (Switzerland)

    2013-09-01

    Two-dimensional simulations, both Vlasov and particle-in-cell, are presented that show the evolution of the field and electron distribution of finite-width, nonlinear electron plasma waves. The intrinsically intertwined effects of self-focusing and dissipation of field energy caused by electron trapping are studied in simulated systems that are hundreds of wavelengths long in the transverse direction but only one wavelength long and periodic in the propagation direction. From various initial wave states, both the width at focus Δm relative to the initial width Δ0 and the maximum field amplitude at focus are shown to be a function of the growth rate of the transverse modulational instability γTPMI divided by the loss rate of field energy νE to electrons escaping the trapping region. With dissipation included, an amplitude threshold for self-focusing γTPMIE~1 is found that supports the analysis of Rose [Phys. Plasmas 12, 012318 (2005)].

  20. Simulation of electrical discharge in a 3.6 Joule miniature plasma focus device using SIMULINK

    Science.gov (United States)

    Jafari, Hossein; Habibi, Morteza

    2014-08-01

    A novel technique has been developed and studied in this paper to simulate the electrical discharge circuit of a 3.6 J miniature plasma focus device (PFD) and investigate the effect of inductance variation on voltage spike and current dip. The technique is based on a correlation between the electrical discharge circuit and plasma dynamics in a very small PFD that operates at the energy of 3.6 J. The simulation inputs include the charging voltage, capacitor bank capacitance, current limiter resistance, by-pass resistance as well as the time-dependent inductance and resistance of the plasma sheath which are calculated by assuming the plasma dynamics as transit times in going from one phase to the next. The variations of the most important elements in the circuit (i.e. the constant and breakdown inductances) and their effects on the current dip are studied in PFDs with low and high constant inductance. The model demonstrated for achieving a good pinch in the PFD, although the total inductance of the system should be low; however there is always an optimum inductance which causes an appropriate pinch. Furthermore, the electrical power produced by the pulsed power supply, the mechanical energy as well as the magnetic energy which are transferred into the plasma tube were obtained from simulation. The graph of electrical power demonstrated a high instantaneous increment in the power transferred into the plasma as one of the greatest advantages of the pulsed power supply. The simulation was performed using software tools within the MATLAB/SIMULINK simulation environment.

  1. Plasma and muscle myostatin in relation to type 2 diabetes.

    Directory of Open Access Journals (Sweden)

    Claus Brandt

    Full Text Available OBJECTIVE: Myostatin is a secreted growth factor expressed in skeletal muscle tissue, which negatively regulates skeletal muscle mass. Recent animal studies suggest a role for myostatin in insulin resistance. We evaluated the possible metabolic role of myostatin in patients with type 2 diabetes and healthy controls. DESIGN: 76 patients with type 2 diabetes and 92 control subjects were included in the study. They were matched for age, gender and BMI. Plasma samples and biopsies from the vastus lateralis muscle were obtained to assess plasma myostatin and expression of myostatin in skeletal muscle. RESULTS: Patients with type 2 diabetes had higher fasting glucose (8.9 versus 5.1 mmol/L, P<0.001, plasma insulin (68.2 versus 47.2 pmol/L, P<0.002 and HOMA2-IR (1.6 versus 0.9, P<0.0001 when compared to controls. Patients with type 2 diabetes had 1.4 (P<0.01 higher levels of muscle myostatin mRNA content than the control subjects. Plasma myostatin concentrations did not differ between patients with type 2 diabetes and controls. In healthy controls, muscle myostatin mRNA correlated with HOMA2-IR (r = 0.30, P<0.01, plasma IL-6 (r = 0.34, P<0.05 and VO2 max (r = -0.26, P<0.05, however, no correlations were observed in patients with type 2 diabetes. CONCLUSIONS: This study supports the idea that myostatin may have a negative effect on metabolism. However, the metabolic effect of myostatin appears to be overruled by other factors in patients with type 2 diabetes.

  2. Search for thermonuclear neutrons in a mega-ampere plasma focus

    Science.gov (United States)

    Klir, D.; Kubes, P.; Paduch, M.; Pisarczyk, T.; Chodukowski, T.; Scholz, M.; Kalinowska, Z.; Bienkowska, B.; Karpinski, L.; Kortanek, J.; Kravarik, J.; Rezac, K.; Ivanova-Stanik, I.; Tomaszewski, K.; Zielinska, E.

    2012-01-01

    Plasma focus experiments were carried out at a modified PF-1000 where the cathode disc was added in front of the anode. Experimental results indicated a fraction of thermonuclear neutrons on the mega-ampere current level. In order to prove the thermonuclear mechanism, the time of neutron production and the neutron energy spectrum were measured by time-of-flight (TOF) diagnostics. Neutron TOF signals showed that the neutron production was a multiphase process and more than one mechanism occurred simultaneously. The occurrence of the thermonuclear mechanism was most evident during the plasma stagnation at low deuterium pressures. At low filling pressures, the narrow width of the neutron energy spectra demonstrated an ion temperature of about 1 keV. The possibility of thermonuclear neutrons was studied also after the stagnation, during the main neutron emission. In this case, the thermonuclear mechanism could be verified by calculating the number of deuterons that participate in the fusion process. For the bulk of thermonuclear plasmas, a significant fraction of plasma should participate in fusion. Finally, the basic consideration of the thermonuclear mechanism in Z-pinches showed the reasonableness of the MagLIF concept.

  3. Comparisons of dense-plasma-focus kinetic simulations with experimental measurements

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Link, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Welch, D. [Voss Scientific, Inc., Albuquerque, NM (United States); Ellsworth, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Falabella, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Tang, V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-06-01

    Dense-plasma-focus (DPF) Z-pinch devices are sources of copious high-energy electrons and ions, x rays, and neutrons. The mechanisms through which these physically simple devices generate such high-energy beams in a relatively short distance are not fully understood and past optimization efforts of these devices have been largely empirical. Previously we reported on fully kinetic simulations of a DPF and compared them with hybrid and fluid simulations of the same device. Here we present detailed comparisons between fully kinetic simulations and experimental data on a 1.2 kJ DPF with two electrode geometries, including neutron yield and ion beam energy distributions. A more intensive third calculation is presented which examines the effects of a fully detailed pulsed power driver model. We also compare simulated electromagnetic fluctuations with direct measurement of radiofrequency electromagnetic fluctuations in a DPF plasma. These comparisons indicate that the fully kinetic model captures the essential physics of these plasmas with high fidelity, and provide further evidence that anomalous resistivity in the plasma arises due to a kinetic instability near the lower hybrid frequency.

  4. Numerical Experiments on Oxygen Plasma Focus: Scaling Laws of Soft X-Ray Yields

    Science.gov (United States)

    Akel, M.

    2013-08-01

    Numerical experiments have been investigated on UNU/ICTP PFF low energy plasma focus device with oxygen filling gas. In these numerical experiments, the temperature window of 119-260 eV has been used as a suitable temperature range for generating oxygen soft X-rays. The Lee model was applied to characterize the UNU/ICTP PFF plasma focus. The optimum soft X-ray yield (Ysxr) was found to be 0.75 J, with the corresponding efficiency of about 0.03 % at pressure of 2.36 Torr and the end axial speed was va = 5 cm/μs. The practical optimum combination of p0, z0 and `a' for oxygen Ysxr was found to be 0.69 Torr, 4.8 cm and 2.366 cm respectively, with the outer radius b = 3.2 cm. This combination gives Ysxr ~ 5 J, with the corresponding efficiency of about 0.16 %. Thus we expect to increase the oxygen Ysxr of UNU/ICTP PFF, without changing the capacitor bank, merely by changing the electrode configuration and operating pressure. Scaling laws on oxygen soft X-ray yield, in terms of storage energies E0, peak discharge current Ipeak and focus pinch current Ipinch were found over the range from 1 kJ to 1 MJ. It was found that the oxygen soft X-ray yields scale well with and for the low inductance (L0 = 30 nH) (where yields are in J and currents in kA). While the soft X-ray yield scaling laws in terms of storage energies were found to be as (E0 in kJ and Ysxr in J) with the scaling showing gradual deterioration as E0 rises over the range. The oxygen soft X-ray yield emitted from plasma focus is found to be about 8.7 kJ for storage energy of 1 MJ. The optimum efficiency for soft X-ray yield (1.1 %) is with capacitor bank energy of 120 kJ. This indicates that oxygen plasma focus is a good soft X-ray source when properly designed.

  5. Plasma proteome analysis of patients with type 1 diabetes with diabetic nephropathy

    DEFF Research Database (Denmark)

    Overgaard, Anne Julie; Hansen, Henning Gram; Lajer, Maria

    2010-01-01

    -driven studies or urinary based investigations. To date only two studies have investigated the proteome of blood in search for new biomarkers, and these studies were conducted in sera from patients with type 2 diabetes. This is the first reported in depth proteomic study where plasma from type 1 diabetic......As part of a clinical proteomics program focused on diabetes and its complications we are looking for new and better protein biomarkers for diabetic nephropathy. The search for new and better biomarkers for diabetic nephropathy has, with a few exceptions, previously focused on either hypothesis...

  6. Focus on strongly correlated quantum fluids: from ultracold quantum gases to QCD plasmas Focus on strongly correlated quantum fluids: from ultracold quantum gases to QCD plasmas

    Science.gov (United States)

    Adams, Allan; Carr, Lincoln D.; Schaefer, Thomas; Steinberg, Peter; Thomas, John E.

    2013-04-01

    The last few years have witnessed a dramatic convergence of three distinct lines of research concerned with different kinds of extreme quantum matter. Two of these involve new quantum fluids that can be studied in the laboratory, ultracold quantum gases and quantum chromodynamics (QCD) plasmas. Even though these systems involve vastly different energy scales, the physical properties of the two quantum fluids are remarkably similar. The third line of research is based on the discovery of a new theoretical tool for investigating the properties of extreme quantum matter, holographic dualties. The main goal of this focus issue is to foster communication and understanding between these three fields. We proceed to describe each in more detail. Ultracold quantum gases offer a new paradigm for the study of nonperturbative quantum many-body physics. With widely tunable interaction strength, spin composition, and temperature, using different hyperfine states one can model spin-1/2 fermions, spin-3/2 fermions, and many other spin structures of bosons, fermions, and mixtures thereof. Such systems have produced a revolution in the study of strongly interacting Fermi systems, for example in the Bardeen-Cooper-Schrieffer (BCS) to Bose-Einstein condensate (BEC) crossover region, where a close collaboration between experimentalists and theorists—typical in this field—enabled ground-breaking studies in an area spanning several decades. Half-way through this crossover, when the scattering length characterizing low-energy collisions diverges, one obtains a unitary quantum gas, which is universal and scale invariant. The unitary gas has close parallels in the hydrodynamics of QCD plasmas, where the ratio of viscosity to entropy density is extremely low and comparable to the minimum viscosity conjecture, an important prediction of AdS/CFT (see below). Exciting developments in the thermodynamic and transport properties of strongly interacting Fermi gases are of broad

  7. Inducing immune tolerance: a focus on Type 1 diabetes mellitus.

    Science.gov (United States)

    Xu, Dan; Prasad, Suchitra; Miller, Stephen D

    2013-09-01

    Tolerogenic strategies that specifically target diabetogenic immune cells in the absence of complications of immunosuppression are the desired treatment for the prevention or even reversal of Type 1 diabetes (T1D). Antigen (Ag)-based therapies must not only suppress disease-initiating diabetogenic T cells that are already activated, but, more importantly, prevent activation of naive auto-Ag-specific T cells that may become autoreactive through epitope spreading as a result of Ag liberation from damaged islet cells. Therefore, identification of auto-Ags relevant to T1D initiation and progression is critical to the design of effective Ag-specific therapies. Animal models of T1D have been successfully employed to identify potential diabetogenic Ags, and have further facilitated translation of Ag-specific tolerance strategies into human clinical trials. In this review, we highlight important advances using animal models in Ag-specific T1D immunotherapies, and the application of the preclinical findings to human subjects. We provide an up-to-date overview of the strengths and weaknesses of various tolerance-inducing strategies, including infusion of soluble Ags/peptides by various routes of delivery, genetic vaccinations, cell- and inert particle-based tolerogenic approaches, and various other strategies that target distinct tolerance-inducing pathways.

  8. Calibration constant of a silver activation counter used with plasma focus devices

    Directory of Open Access Journals (Sweden)

    GR Etaati

    2010-03-01

    Full Text Available The silver activation counters are commonly used for pulsed-neutron yield measurements especially in plasma focus devices. The counter normally consists of a Geiger-Muller tube along with silver foils and polyethylene (as a moderator, which is calibrated against an Am-Be radioisotope neutron source. The neutrons, after being slowed-down in the polyethylene, activate the silver foils. By measuring the foil activity with a Geiger-Muller counter, the neutron yield is determined. In the present paper, the activation counter’s calibration constant calculation using the MCNP4C code is explained. The calculated calibration constant is in good agreement with the experimental results.

  9. Pleiotropic effects of fenofibrate: focus on type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Aleksandr Sergeevich Ametov

    2014-09-01

    Full Text Available AimsThe aim of the present study was to investigate the role of chronic low-grade inflammation in the development of the diabetic neuropathy and the possibility of its medical treatment with fenofibrate (145 mg/day.Materials and MethodsThis trial included 60 patients with type 2 diabetes mellitus. The serum levels of several factors were measured: tumour necrosis factor-α (TNF-α, interleukin-1β (IL-1β, interleukin-6 (IL-6, C-reactive protein (CRP, markers of oxidative stress (malondialdehyde levels, haemostasis, uric acid, glycaemic and lipid profile and the peripheral status (electromyography, total symptom score [TSS] and neuropathy impairment score in the lower limbs [NIS-LL]. Follow-up was at 24 weeks.ResultsA significant negative correlation was found between the excitation rate of the sural nerve and levels of TNF, IL-6 and CRP (p <0.05. A number of changes were observed in the group of patients treated with fenofibrate (145 mg, daily for 24 weeks: Levels of TNF decreased from 9.6±3.68 to 8.1±3.02 pg/ml (p <0.05, IL-6 decreased from 3.3±1.69 to 2.7±1.28 pg/ml (p <0.05, CRP decreased from 5.6±3.63 to 3.1±2.34 mg/l (p <0.05, thiobarbituric acid (TBARS decreased from 3.1±089 to 2.6±1.21 mmol/l (p >0.05, uric acid decreased from 364±69.85 to 296.8±87.3 mmol/l (p <0.05 and fibrinogen decreased from 4.1±0.59 to 3.4±0.71 g/l (p <0.05. Improved levels of total cholesterol, triglycerides, HDL, VLDL and atherogenic index (p <0.05 were observed. Significantly increased M-wave in extensor digitorum brevis muscle was observed, from 5.25±2.31 to 6.3±3.14 mV (p <0.05. In addition, TSS changed from 9.55±1.53 to 7.28±1.26 (p <0.005 and NIS-LL changed from 10.12±2.05 to 8.24±1.68 (p <0.05.ConclusionA correlation was found between EMG parameters and serum levels of inflammatory markers. Fenofibrate significantly reduced levels of inflammatory cytokines and improved lipid and purine metabolism as well as the function of the peripheral

  10. Catalytic action of β source on x-ray emission from plasma focus

    Science.gov (United States)

    Ahmad, S.; Sadiq, Mehboob; Hussain, S.; Shafiq, M.; Zakaullah, M.; Waheed, A.

    2006-01-01

    The influence of preionization around the insulator sleeve by a mesh-type β source (Ni6328) for the x-ray emission from a (2.3-3.9 kJ) plasma focus device is investigated. Quantrad Si p-i-n diodes along with suitable filters are employed as time-resolved x-ray detectors and a multipinhole camera with absorption filters is used for time-integrated analysis. X-ray emission in 4π geometry is measured as a function of argon and hydrogen gas filling pressures with and without β source at different charging voltages. It is found that the pressure range for the x-ray emission is broadened, x-ray emission is enhanced, and shot to shot reproducibility is improved with the β source. With argon, the CuKα emission is estimated to be 27.14 J with an efficiency of 0.7% for β source and 21.5 J with an efficiency of 0.55% without β source. The maximum x-ray yield in 4π geometry is found to be about 68.90 J with an efficiency of 1.8% for β source and 54.58 J with an efficiency of 1.4% without β source. With hydrogen, CuKα emission is 11.82 J with an efficiency of 0.32% for β source and 10.07 J with an efficiency of 0.27% without β source. The maximum x-ray yield in 4π geometry is found to be 30.20 J with an efficiency of 0.77% for β source and 25.58 J with an efficiency of 0.6% without β source. The x-ray emission with Pb insert at the anode tip without β source is also investigated and found to be reproducible and significantly high. The maximum x-ray yield is estimated to be 46.6 J in 4π geometry with an efficiency of 1.4% at 23 kV charging voltage. However, degradation of x-ray yield is observed when charging voltage exceeds 23 kV for Pb insert. From pinhole images it is observed that the x-ray emission due to the bombardment of electrons at the anode tip is dominant in both with and without β source.

  11. Surgical treatment of unicentric plasma cell histological type Castleman's disease

    Directory of Open Access Journals (Sweden)

    Marić Nebojša

    2011-01-01

    Full Text Available Introduction. Castleman’s disease or angiofollicular lymph hyperplasia is a rare disease with two identified clinical forms. Unicentric or localized form is characterized by isolated growth of lymph nodes, most often in mediastinum, and multicentric form is expressed as systemic disease with spread lymphadenopathy, organomegaly and presence of general symptoms of the disease. Histological types are hyalovascular, plasma-cell and transitive (mixed cell. Case report. This case report shows a woman, 59 years old, with unicentric form of plasma-cell type of Castleman’s disease. Unicentric form is usually shown as hyalovascular histological type, extremely rare as plasma-cell type, and transitive (mixed cell type was never described in literature as localized clinical form. The disease was manifested with chest pain, loss of body weight, exhaustion and weakness of legs. Further diagnostic procedures found the presence of enlarged lymph nodes paratracheally right, in a close contact with vena cava superior. The disease was confirmed by histopathological analysis of bioptated mediastinal lymph node after mediastinoscopy. Surgical treatment included extirpation of enlarged lymph nodes. After the regular postoperative condition, a full therapy effect was confirmed. Conclusion. Unicentric form of Castleman’s disease is expressed with enlarged lymph nodes on predilected places, usually in mediastinum. Surgical treatment is best method for the management of the disease and brings a full recovery of patient.

  12. Deposition of magnesium nitride thin films on stainless steel-304 substrates by using a plasma focus device

    Science.gov (United States)

    Ramezani, Amir Hoshang; Habibi, Maryam; Ghoranneviss, Mahmood

    2014-08-01

    In this research, for the first time, we synthesize magnesium nitride thin films on 304-type stainless steel substrates using a Mather-type (2 kJ) plasma focus (PF) device. The films of magnesium nitride are coated with different number of focus shots (like 15, 25 and 35) at a distance of 8 cm from the anode tip and at 0° angular position with respect to the anode axis. For investigation of the structural properties and surface morphology of magnesium nitride films, we utilized the X-ray diffractometer (XRD), atomic force microscopy (AFM) and scanning electron microscopy (SEM) analysis, respectively. Also, the elemental composition is characterized by energy-dispersive X-ray (EDX) analysis. Furthermore, Vicker's microhardness is used to study the mechanical properties of the deposited films. The results show that the degree of crystallinity of deposited thin films (from XRD), the average size of particles and surface roughness (from AFM), crystalline growth of structures (from SEM) and the hardness values of the films depend on the number of focus shots. The EDX analysis demonstrates the existence of the elemental composition of magnesium in the deposited samples.

  13. AmBe Radiological Source Replacement Using Dense Plasma Focus Z-Pinch

    Science.gov (United States)

    Shaw, Brian; Povilus, Alexander; Chapman, Steven; Podpaly, Yuri; Cooper, Christopher; Higginson, Drew; Link, Anthony; Schmidt, Andrea

    2016-10-01

    A dense plasma focus (DPF) is a compact plasma gun that produces high energy ion beams up to several MeV through strong potential gradients formed from m=0 plasma instabilities. These ion beams can be used to replace radiological sources for a variety of applications. Americium-beryllium (AmBe) neutron sources are commonly used for oil well logging. An optimized DPF produces high energy helium ion beams of 2+ MeV which can interact with a beryllium target to produce neutrons. The alpha-Be interaction produces a neutron energy spectrum similar to the neutrons produced by the AmBe reaction. To demonstrate this concept experimentally a 2 kJ DPF is used to produce a beam of alpha particles which interacts with a beryllium target. We report on the improvements made to the DPF platform using He gas and the observation of 3.0 ×104 peak neutrons generated per shot. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  14. Effect of driver impedance on dense plasma focus Z-pinch neutron yield

    Energy Technology Data Exchange (ETDEWEB)

    Sears, Jason, E-mail: sears8@llnl.gov, E-mail: schmidt36@llnl.gov; Link, Anthony, E-mail: sears8@llnl.gov, E-mail: schmidt36@llnl.gov; Schmidt, Andrea, E-mail: sears8@llnl.gov, E-mail: schmidt36@llnl.gov [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States); Welch, Dale [Voss Scientific, Albuquerque, NM 87108 (United States)

    2014-12-15

    The Z-pinch phase of a dense plasma focus (DPF) heats the plasma by rapid compression and accelerates ions across its intense electric fields, producing neutrons through both thermonuclear and beam-target fusion. Driver characteristics have empirically been shown to affect performance, as measured by neutron yield per unit of stored energy. We are exploring the effect of driver characteristics on DPF performance using particle-in-cell (PIC) simulations of a kJ scale DPF. In this work, our PIC simulations are fluid for the run-down phase and transition to fully kinetic for the pinch phase, capturing kinetic instabilities, anomalous resistivity, and beam formation during the pinch. The anode-cathode boundary is driven by a circuit model of the capacitive driver, including system inductance, the load of the railgap switches, the guard resistors, and the coaxial transmission line parameters. It is known that the driver impedance plays an important role in the neutron yield: first, it sets the peak current achieved at pinch time; and second, it affects how much current continues to flow through the pinch when the pinch inductance and resistance suddenly increase. Here we show from fully kinetic simulations how total neutron yield depends on the impedance of the driver and the distributed parameters of the transmission circuit. Direct comparisons between the experiment and simulations enhance our understanding of these plasmas and provide predictive design capability for neutron source applications.

  15. Plasma focus neutron anisotropy measurements and influence of a deuteron beam obstacle

    Science.gov (United States)

    Talebitaher, A.; Springham, S. V.; Rawat, R. S.; Lee, P.

    2017-03-01

    The deuterium-deuterium (DD) fusion neutron yield and anisotropy were measured on a shot-to-shot basis for the NX2 plasma focus (PF) device using two beryllium fast-neutron activation detectors at 0° and 90° to the PF axis. Measurements were performed for deuterium gas pressures in the range 6-16 mbar, and positive correlations between neutron yield and anisotropy were observed at all pressures. Subsequently, at one deuterium gas pressure (13 mbar), the contribution to the fusion yield produced by the forwardly-directed D+ ion beam, emitted from the plasma pinch, was investigated by using a circular Pyrex plate to obstruct the beam and suppress its fusion contribution. Neutron measurements were performed with the obstacle positioned at two distances from the anode tip, and also without the obstacle. It was found that 80% of the neutron yield originates in the plasma pinch column and just above that. In addition, proton pinhole imaging was performed from the 0° and 90° directions to the pinch. The obtained proton images are consistent with the conclusion that DD fusion is concentrated ( 80%) in the pinch column region.

  16. Construction of a Compact, Low-Inductance, 100 J Dense Plasma Focus for Yield Optimization Studies

    Science.gov (United States)

    Cooper, Christopher; Povilus, Alex; Chapman, Steven; Falabella, Steve; Podpaly, Yuri; Shaw, Brian; Liu, Jason; Schmidt, Andrea

    2016-10-01

    A new 100 J mini dense plasma focus (DPF) is constructed to optimize neutron yields for a variety of plasma conditions and anode shapes. The device generates neutrons by leveraging instabilities that occur during a z-pinch in a plasma sheath to accelerate a beam of deuterium ions into a background deuterium gas target. The features that distinguish this miniDPF from previous 100 J devices are a compact, engineered electrode geometry and a low-impedance driver. The driving circuit inductance is minimized by mounting the capacitors close to the back of the anode and cathode yields. The anode can rapidly be changed out to test new designs. The neutron yield and 2D images of the visible light emission are compared to simulations with the hybrid kinetic code LSP which can directly simulate the device and anode designs. Initial studies of the sheath physics and neutron yields for a scaling of discharge voltages and neutral fill pressures are presented. Prepared by LLNL under Contract DE-AC52-07NA27344.

  17. Hundred joules plasma focus device as a potential pulsed source for in vitro cancer cell irradiation

    Science.gov (United States)

    Jain, J.; Moreno, J.; Andaur, R.; Armisen, R.; Morales, D.; Marcelain, K.; Avaria, G.; Bora, B.; Davis, S.; Pavez, C.; Soto, L.

    2017-08-01

    Plasma focus devices may arise as useful source to perform experiments aimed to study the effects of pulsed radiation on human cells in vitro. In the present work, a table top hundred joules plasma focus device, namely "PF-400J", was adapted to irradiate colorectal cancer cell line, DLD-1. For pulsed x-rays, the doses (energy absorbed per unit mass, measured in Gy) were measured using thermoluminescence detectors (TLD-100 dosimeters). The neutron fluence and the average energy were used to estimate the pulsed neutron doses. Fifty pulses of x-rays (0.12 Gy) and fifty pulses of neutrons (3.5 μGy) were used to irradiate the cancer cells. Irradiation-induced DNA damage and cell death were assessed at different time points after irradiation. Cell death was observed using pulsed neutron irradiation, at ultralow doses. Our results indicate that the PF-400J can be used for in vitro assessment of the effect of pulsed radiation in cancer cell research.

  18. The Role of the Driver Circuit in the Neutron Yield of the Plasma Focus

    Science.gov (United States)

    Sears, Jason; Schmidt, Andrea; Link, Anthony; Welch, Dale

    2015-11-01

    Emperical observations have suggested that dense plasma focus (DPF) neutron yield increases with driver impedance. Using the particle-in-cell code LSP, we reproduce this trend in a kJ DPF, and demonstrate in detail how driver impedance is coupled to neutron output. We implement a 2-D model of the plasma focus including self-consistent circuit-driven boundary conditions. We show that m=0 growth is central to beam formation and is a chaotic, non-deterministic process. Neutrons are produced when high, short-lived electric fields in the low-density cavity of an m=0 mode accelerate a beam of ions into the dense downstream pinch region. Neutron yield is highest when the ion beam is generated within 50 ns of the pinch formation on axis, because at that time the pinch (target) density is highest. High driver impedance contributes to prompt beam formation in two ways. First, the high impedance driver, losing less energy to run-down, has a faster run-in velocity and hence larger Rayleigh-Taylor features that more readily seed the m=0 instability. Second, the shorter anode of the high-impedance driver retains less trailing mass in the run-down region and thus exhibits fewer and less parasitic restrikes. Prepared by LLNL under Contract DE-AC52-07NA27344.

  19. Assessment of image quality in x-ray radiography imaging using a small plasma focus device

    Science.gov (United States)

    Kanani, A.; Shirani, B.; Jabbari, I.; Mokhtari, J.

    2014-08-01

    This paper offers a comprehensive investigation of image quality parameters for a small plasma focus as a pulsed hard x-ray source for radiography applications. A set of images were captured from some metal objects and electronic circuits using a low energy plasma focus at different voltages of capacitor bank and different pressures of argon gas. The x-ray source focal spot of this device was obtained to be about 0.6 mm using the penumbra imaging method. The image quality was studied by several parameters such as image contrast, line spread function (LSF) and modulation transfer function (MTF). Results showed that the contrast changes by variations in gas pressure. The best contrast was obtained at a pressure of 0.5 mbar and 3.75 kJ stored energy. The results of x-ray dose from the device showed that about 0.6 mGy is sufficient to obtain acceptable images on the film. The measurements of LSF and MTF parameters were carried out by means of a thin stainless steel wire 0.8 mm in diameter and the cut-off frequency was obtained to be about 1.5 cycles/mm.

  20. Radiography using a dense plasma focus device as a source of pulsed X-rays

    Science.gov (United States)

    Herrera, Julio; Castillo, Fermín; Gamboa, Isabel; Rangel, José

    2007-11-01

    Soft and hard X-ray emissions have been studied in the FN-II, which is a small dense plasma focus machine (5 kJ), operating at the Instituto de Ciencias Nucleares, UNAM, using aluminum filtered pin-hole cameras. Their angular distribution has been measured using TLD-200 dosimeters [1]. Their temporal evolution has been observed by means of a PIN diode, and scinltillators coupled to photomultipliers outside the discharge chamber. The X rays source can be concentrated by placing a needle on the end of the electrode. X-rays crossing across a 300 micron aluminum window, through the axis of the machine, can be used to obtain high contrast radiographs, with an average dose of 0.4 mGy per shot. In contrast, the average dose with a hollow cathode is 0.2 mGy per shot. This work is partially supported by grant IN105705 de la DGAPA-UNAM. [1] F. Castillo, J.J.E. Herrera, J. Rangel, I. Gamboa, G. Espinosa y J.I. Golzarri ``Angular Distribution of fusion products and X-rays emitted by a small dense plasma focus machine'' Journal of Applied Physics 101 013303-1-7 (2007).

  1. Note: Repetitive operation of the capacitor bank of the low-voltage miniature plasma focus at 50 Hz

    Science.gov (United States)

    Shukla, Rohit; Shyam, Anurag

    2013-10-01

    We have already reported the low-voltage operation of a plasma focus describing the operation of plasma focus at 4.2 kV which proposes possibility of making a repetitive system using compact driving source. Another recent article describes that the same capacitor-bank can drive the plasma focus for a measured ˜5 × 104 neutrons per shot at 5 kV and 59 kA current. In the present work, repetitive operation of the capacitor-bank of plasma focus is done and that too is being reported at a very high repetition rate of 50 Hz using very simple scheme of charging and triggering the bank. The bank is continuously discharged to burst duration of 20 s in this configuration admeasuring a thousand shots.

  2. Personality type and leadership focus: Relationship between self and line- manager perceptions

    Directory of Open Access Journals (Sweden)

    Grant Sieff

    2009-04-01

    Full Text Available The relationship between personality type and leadership focus is examined in this article. Personality type is assessed by means of the Myers-Briggs Type Indicator (MBTI, and leadership focus is explored both with participants and their line-managers using a Leadership Focus Questionnaire. Petroleum company mid-level managers form the target population of 220. Three leadership focus hypotheses are tested with 53 respondents, addressing (1 optimising external and internal focus, (2 fit with organisation type, and (3 managing a multiple focus. The Pearson Correlation Coefficient, ANOVA and paired T-tests are applied. Results show that in circumstances associated with change, Feeling and Perceiving types are favoured for managing the stress of competing leadership demands. Line-managers of participants rely more on Intuition while participants prefer Sensing in dealing with external stakeholders.

  3. The plasma membrane calcium pumps: focus on the role in (neuro)pathology.

    Science.gov (United States)

    Brini, Marisa; Carafoli, Ernesto; Calì, Tito

    2017-02-19

    The plasma membrane Ca(2+) ATPase (PMCA pump) is a member of the superfamily of P-type pumps. It is organized in the plasma membrane with ten transmembrane helices and two main cytosolic loops, one of which contains the catalytic center. It also contains a long C-terminal tail that houses the binding site for calmodulin, the main regulator of the activity of the pump. The pump also contains a number of other regulators, among them acidic phospholipids, kinases, and numerous protein interactors. Separate genes code for 4 basic pump isoforms in mammals, additional isoform complexity being generated by the alternative splicing of primary transcripts. Pumps 1 and 4 are expressed ubiquitously, pumps 2 and 3 are tissue restricted, with preference for the nervous system. In essentially all cells, the pump coexists with much more powerful systems that clear Ca(2+) from the cytosol, e.g. the SERCA pump and the Na(+)/Ca(2+) exchanger. Its role in the global regulation of cellular Ca(2+) homeostasis is thus quantitatively marginal: its main function is the regulation of Ca(2+) signaling in selected sub-plasma membrane microdomains where Ca(2+) modulated interactors also reside. Malfunctions of the pump linked to genetic mutations are now described with increasing frequency, the disease phenotypes being especially severe in the nervous system where isoforms 2 and 3 predominate. The analysis of the pump defects suggests that the disease phenotypes are likely to be related to the imperfect modulation of Ca(2+) signaling in selected sub-plasma membrane microdomains, leading to the defective control of the activity of important Ca(2+) dependent interactors.

  4. Investigation of structural properties of chromium thin films prepared by a plasma focus device

    Science.gov (United States)

    Javadi, S.; Habibi, M.; Ghoranneviss, M.; Lee, S.; Saw, S. H.; Behbahani, R. A.

    2012-08-01

    We report the synthesis of chromium thin films on Si(400) substrates by utilizing a low-energy (1.6 kJ) plasma focus device. The films of chromium are deposited with different numbers of focus shots (15, 25 and 35) at a distance of 8 cm and at 0° angular position with respect to the anode axis. The films are investigated structurally by x-ray diffraction analysis and morphologically by atomic force microscopy and scanning electron microscopy. The elemental composition is characterized by energy dispersive x-ray analysis. Furthermore, Vicker's micro hardness is used to study the mechanical properties of the deposited films. The degree of crystallinity of chromium films, the size of the particles and the hardness values of the films increase when the number of focus shots is raised from 15 to 25 and then decrease when the substrate is treated with 35 shots. We discuss the dynamic processes involved in the formation of the chromium films.

  5. Ion probe beam experiments and kinetic modeling in a dense plasma focus Z-pinch

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, A., E-mail: schmidt36@llnl.gov; Ellsworth, J., E-mail: schmidt36@llnl.gov; Falabella, S., E-mail: schmidt36@llnl.gov; Link, A., E-mail: schmidt36@llnl.gov; McLean, H., E-mail: schmidt36@llnl.gov; Rusnak, B., E-mail: schmidt36@llnl.gov; Sears, J., E-mail: schmidt36@llnl.gov; Tang, V., E-mail: schmidt36@llnl.gov [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States); Welch, D. [Voss Scientific, LLC, 418 Washington St SE, Albuquerque NM 87108 (United States)

    2014-12-15

    The Z-pinch phase of a dense plasma focus (DPF) emits multiple-MeV ions in a ∼cm length. The mechanisms through which these physically simple devices generate such high energy beams in a relatively short distance are not fully understood. We are exploring the origins of these large gradients using measurements of an ion probe beam injected into a DPF during the pinch phase and the first kinetic simulations of a DPF Z-pinch. To probe the accelerating fields in our table top experiment, we inject a 4 MeV deuteron beam along the z-axis and then sample the beam energy distribution after it passes through the pinch region. Using this technique, we have directly measured for the first time the acceleration of an injected ion beam. Our particle-in-cell simulations have been benchmarked on both a kJ-scale DPF and a MJ-scale DPF. They have reproduced experimentally measured neutron yields as well as ion beams and EM oscillations which fluid simulations do not exhibit. Direct comparisons between the experiment and simulations enhance our understanding of these plasmas and provide predictive design capability for accelerator and neutron source applications.

  6. Fully Three-dimensional Simulation and Modeling of a Dense Plasma Focus

    CERN Document Server

    Meehan, B T

    2014-01-01

    A Dense Plasma Focus (DPF) is a pulsed-power machine that electromagnetically accelerates and cylindrically compresses a shocked plasma in a Z-pinch. The pinch results in a brief (about 100 nanosecond) pulse of X-rays, and, for some working gases, also a pulse of neutrons. A great deal of experimental research has been done into the physics of DPF reactions, and there exist mathematical models describing its behavior during the different time phases of the reaction. Two of the phases, known as the inverse pinch and the rundown, are approximately governed by magnetohydrodynamics, and there are a number of well-established codes for simulating these phases in two dimensions or in three dimensions under the assumption of axial symmetry. There has been little success, however, in developing fully three-dimensional simulations. In this work we present three-dimensional simulations of DPF reactions and demonstrate that 3D simulations predict qualitatively and quantitatively different behavior than their 2D counterp...

  7. Fully three-dimensional simulation and modeling of a dense plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Meehan, B. T.; Niederhaus, J. H. J.

    2014-10-01

    A dense plasma focus (DPF) is a pulsed-power machine that electromagnetically accelerates and cylindrically compresses a shocked plasma in a Z-pinch. The pinch results in a brief (~ 100 ns) pulse of X-rays, and, for some working gases, also a pulse of neutrons. A great deal of experimental research has been done into the physics of DPF reactions, and there exist mathematical models describing its behavior during the different time phases of the reaction. Two of the phases, known as the inverse pinch and the rundown, are approximately governed by magnetohydrodynamics, and there are a number of well-established codes for simulating these phases in two dimensions or in three dimensions under the assumption of axial symmetry. There has been little success, however, in developing fully three-dimensional simulations. In this work we present three-dimensional simulations of DPF reactions and demonstrate that three-dimensional simulations predict qualitatively and quantitatively different behavior than their two-dimensional counterparts. One of the most important quantities to predict is the time duration between the formation of the gas shock and Z-pinch, and the three-dimensional simulations more faithfully represent experimental results for this time duration and are essential for accurate prediction of future experiments.

  8. Low-Energy Plasma Focus Device as an Electron Beam Source

    Science.gov (United States)

    Seong Ling, Yap; Naresh Kumar, Nitturi; Lian Kuang, Lim; Chiow San, Wong

    2014-01-01

    A low-energy plasma focus device was used as an electron beam source. A technique was developed to simultaneously measure the electron beam intensity and energy. The system was operated in Argon filling at an optimum pressure of 1.7 mbar. A Faraday cup was used together with an array of filtered PIN diodes. The beam-target X-rays were registered through X-ray spectrometry. Copper and lead line radiations were registered upon usage as targets. The maximum electron beam charge and density were estimated to be 0.31 μC and 13.5 × 1016/m3, respectively. The average energy of the electron beam was 500 keV. The high flux of the electron beam can be potentially applicable in material sciences. PMID:25544952

  9. Radiation protection of PFMA-1, a plasma focus for medical applications.

    Science.gov (United States)

    Fabbri, A; Frignani, M; Mannucci, S; Mostacci, D; Rocchi, F; Sumini, M; Teodori, F; Angeli, E; Tartari, A; Cucchi, G

    2007-12-01

    A plasma focus is being developed for breeding short-lived radionuclides. The different radiation protection issues and concerns posed by the machine once in operation are analysed and discussed. Activation is shown to be totally negligible and likewise neutron emission is found to pose no concern at all. The only source of radiation risk is found to rest in the radionuclides produced, 18F and 15 O, generating a peak exposure of 1.114 Sv y(-1) at the distance of closest approach of 2.5 m. Shielding to protect against this hazard is calculated to be 5 cm Pb or 54 cm concrete for the operation area and 5.5 cm Pb for the transportation flask.

  10. Analysis for Radiation and Shielding Dose in Plasma Focus Neutron Source Using FLUKA

    Science.gov (United States)

    Nemati, M. J.; Amrollahi, R.; Habibi, M.

    2012-06-01

    Monte Carlo simulations have been performed for the attenuation of neutron radiation produced at Plasma focus (PF) devices through various shielding design. At the test site it will be fired with deuterium and tritium (D-T) fusion resulting in a yield of about 1013 fusion neutrons of 14 MeV. This poses a radiological hazard to scientists and personnel operating the device. The goal of this paper was to evaluate various shielding options under consideration for the PF operating with D-T fusion. Shields of varying neutrons-shielding effectiveness were investigated using concrete, polyethylene, paraffin and borated materials. The most effective shield, a labyrinth structure, allowed almost 1,176 shots per year while keeping personnel under 20 mSV of dose. The most expensive shield that used, square shield with 100 cm concrete thickness on the walls and Borated paraffin along with borated polyethylene added outside the concrete allowed almost 15,000 shot per year.

  11. Ion beam and neutron output from a sub-kilojoule dense plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Ellsworth, J. L., E-mail: ellsworth7@llnl.gov; Falabella, S., E-mail: ellsworth7@llnl.gov; Schmidt, A., E-mail: ellsworth7@llnl.gov; Tang, V., E-mail: ellsworth7@llnl.gov [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States)

    2014-12-15

    We are seeking to gain a better fundamental understanding of the ion beam acceleration and neutron production dense plasma focus (DPF) device. Experiments were performed on a kilojoule level, fast rise time DPF located at LLNL. Ion beam spectra and neutron yield were measured for deuterium pinches. Visible light images of the pinch are used to determine the pinch length. In addition, an RF probe was placed just outside the cathode to measure fluctuations in E{sub z} up to 6 GHz, which is within the range of the lower hybrid frequencies. We find these oscillations arise at a characteristic frequency near 4 GHz during the pinch. Comparisons of the neutron yield and ion beam characteristics are presented. The neutron yield is also compared to scaling laws.

  12. Feasibility analysis of a Plasma Focus neutron source for BNCT treatment of transplanted human liver

    Science.gov (United States)

    Benzi, V.; Mezzetti, F.; Rocchi, F.; Sumini, M.

    2004-01-01

    Boron Neutron Capture Therapy preliminary treatments on transplanted human liver have been recently conducted at Pavia University. The need of high fluences of thermal neutrons imposed the use of the available thermal channel of a TRIGA reactor properly modified for this application. We analyse the possibility of using the Plasma Focus (PF) machine as a pulsed neutron source for this medical application instead of a nuclear reactor. Thermalization of the fast (2.45 MeV for D-D reactions) neutrons produced by the PF is gained with a paraffin or polyethylene moderator which contains both the neutron source and the irradiation chamber. The design parameters of a PF optimized for such an application are discussed, as well as other considerations on the advantages that this machine can bring to this kind of cancer therapy.

  13. Low Energy Plasma Focus as an Intense X-ray Source for Radiography

    Institute of Scientific and Technical Information of China (English)

    S. Hussain; M. Zakaullah; Shujaat Ali; A. Waheed

    2004-01-01

    Study on X-ray emission from a low energy (1.8 k J) plasma focus device powered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175 kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energy windows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry is found to be (27.3±1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52 ±0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at the anode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device as an intense X-ray source for radiography is demonstrated.

  14. MCNP Simulation to Hard X-Ray Emission of KSU Dense Plasma Focus Machine

    CERN Document Server

    Mohamed, Amgad E

    2015-01-01

    The MCNP program used to simulate the hard x-ray emission from KSU dense plasma focus device, an electron beam spectrum of maximum energy 100 keV was used to hit anode target. The bremsstrahlung radiation was measured using the F2 tally functions on the chamber walls and on a virtual sphere surrounding the machine, the radiation spectrum was recorded for various anode materials like tungsten, stainless steel and molybdenum. It was found that tungsten gives the best and the most intense radiation for the same electron beam. An aluminum filter of thickness 2mm and 4mm was used to cutoff the lower energy band from the x-ray spectrum. It was found that the filters achieved the mission and there is no distinct difference in between.

  15. Silicon dioxide mask by plasma enhanced atomic layer deposition in focused ion beam lithography

    Science.gov (United States)

    Liu, Zhengjun; Shah, Ali; Alasaarela, Tapani; Chekurov, Nikolai; Savin, Hele; Tittonen, Ilkka

    2017-02-01

    In this work, focused ion beam (FIB) lithography was developed for plasma enhanced atomic layer deposited (PEALD) silicon dioxide SiO2 hard mask. The PEALD process greatly decreases the deposition temperature of the SiO2 hard mask. FIB Ga+ ion implantation on the deposited SiO2 layer increases the wet etch resistivity of the irradiated region. A programmed exposure in FIB followed by development in a wet etchant enables the precisely defined nanoscale patterning. The combination of FIB exposure parameters and the development time provides greater freedom for optimization. The developed process provides high pattern dimension accuracy over the tested range of 90–210 nm. Utilizing the SiO2 mask developed in this work, silicon nanopillars with 40 nm diameter were successfully fabricated with cryogenic deep reactive ion etching and the aspect ratio reached 16:1. The fabricated mask is suitable for sub-100 nm high aspect ratio silicon structure fabrication.

  16. Low-Energy Plasma Focus Device as an Electron Beam Source

    Directory of Open Access Journals (Sweden)

    Muhammad Zubair Khan

    2014-01-01

    Full Text Available A low-energy plasma focus device was used as an electron beam source. A technique was developed to simultaneously measure the electron beam intensity and energy. The system was operated in Argon filling at an optimum pressure of 1.7 mbar. A Faraday cup was used together with an array of filtered PIN diodes. The beam-target X-rays were registered through X-ray spectrometry. Copper and lead line radiations were registered upon usage as targets. The maximum electron beam charge and density were estimated to be 0.31 μC and 13.5×1016/m3, respectively. The average energy of the electron beam was 500 keV. The high flux of the electron beam can be potentially applicable in material sciences.

  17. Measurements of fast electron beams and soft X-ray emission from plasma-focus experiments

    Directory of Open Access Journals (Sweden)

    Surała Władysław

    2016-06-01

    Full Text Available The paper reports results of the recent experimental studies of pulsed electron beams and soft X-rays in plasma-focus (PF experiments carried out within a modified PF-360U facility at the NCBJ, Poland. Particular attention was focused on time-resolved measurements of the fast electron beams by means of two different magnetic analyzers, which could record electrons of energy ranging from about 41 keV to about 715 keV in several (6 or 8 measuring channels. For discharges performed with the pure deuterium filling, many strong electron signals were recorded in all the measuring channels. Those signals were well correlated with the first hard X-ray pulse detected by an external scintillation neutron-counter. In some of the analyzer channels, electron spikes (lasting about dozens of nanoseconds and appearing in different instants after the current peculiarity (so-called current dip were also recorded. For several discharges, fast ion beams, which were emitted along the z-axis and recorded with nuclear track detectors, were also investigated. Those measurements confirmed a multibeam character of the ion emission. The time-integrated soft X-ray images, which were taken side-on by means of a pinhole camera and sensitive X-ray films, showed the appearance of some filamentary structures and so-called hot spots. The application of small amounts of admixtures of different heavy noble gases, i.e. of argon (4.8% volumetric, krypton (1.6% volumetric, or xenon (0.8% volumetric, decreased intensity of the recorded electron beams, but increased intensity of the soft X-ray emission and showed more distinct and numerous hot spots. The recorded electron spikes have been explained as signals produced by quasi-mono-energetic microbeams emitted from tiny sources (probably plasma diodes, which can be formed near the observed hot spots.

  18. High-resolution X-ray focusing concave (elliptical) curved crystal spectrograph for laser-produced plasma

    Institute of Scientific and Technical Information of China (English)

    Shali xiao(肖沙里); Yingjun Pan(潘英俊); Xianxin Zhong(钟先信); Xiancai Xiong(熊先才); Guohong Yang(杨国洪); Zongli Liu(刘宗礼); Yongkun Ding(丁永坤)

    2004-01-01

    The X-ray spectrum emitted from laser-produced plasma contains plentiful information.X-ray spectrometer is a powerful tool for plasma diagnosis and studying the information and evolution of the plasma.X-ray concave(elliptical)curved crystals analyzer was designed and manufactured to investigate the properties of laser-produced plasma.The experiment was carried out on Mianyang Xingguang-ⅡFacility and aimed at investigating the characteristics of a high density iron plasma.Experimental results using KAP,LIF,PET,and MICA curved crystal analyzers are described,and the spectra of Au,Ti laser-produced plasma are shown.The focusing crystal analyzer clearly gave an increase in sensitivity over a flat crystal.

  19. Experimental results on the irradiation of nuclear fusion relevant materials at the dense plasma focus ‘Bora’ device

    Science.gov (United States)

    Cicuttin, A.; Crespo, M. L.; Gribkov, V. A.; Niemela, J.; Tuniz, C.; Zanolli, C.; Chernyshova, M.; Demina, E. V.; Latyshev, S. V.; Pimenov, V. N.; Talab, A. A.

    2015-06-01

    Samples of materials counted as perspective ones for use in the first-wall and construction elements in nuclear fusion reactors (FRs) with magnetic and inertial plasma confinement (W, Ti, Al, low-activated ferritic steel ‘Eurofer’ and some alloys) were irradiated in the dense plasma focus (DPF) device ‘Bora’ having a bank energy of ⩽5 kJ. The device generates hot dense (T ˜ 1 keV, n ˜ 1019 cm-3) deuterium plasma, powerful plasma streams (v ˜ 3 × 107 cm s-1) and fast (E ˜ 0.1 … 1.0 MeV) deuterons of power flux densities q up to 1010 and 1012 W cm-2 correspondingly. ‘Damage factor’ F = q × τ0.5 ensures an opportunity to simulate radiation loads (predictable for both reactors types) by the plasma/ion streams, which have the same nature and namely those parameters as expected in the FR modules. Before and after irradiation we provided investigations of our samples by means of a number of analytical techniques. Among them we used optical and scanning electron microscopy to understand character and parameters of damageability of the surface layers of the samples. Atomic force microscopy was applied to measure roughness of the surface after irradiation. These characteristics are quite important for understanding mechanisms and values of dust production in FR that may relate to tritium retention and emergency situations in FR facilities. We also applied two new techniques. For the surface we elaborated the portable x-ray diffractometer that combines x-ray single photon detection with high spectroscopic and angular resolutions. For bulk damageability investigations we applied an x-ray microCT system where x-rays were produced by a Hamamatsu microfocus source (150 kV, 500 µA, 5 µm minimum focal spot size). The detector was a Hamamatsu CMOS flat panel coupled to a fibre optic plate under the GOS scintillator. The reconstruction of three-dimensional data was run with Cobra 7.4 and DIGIX CT software while VG Studio Max 2.1, and Amira 5.3 were used for

  20. Isolated and Integrated Form-Focused Instruction: Effects on Different Types of L2 Knowledge

    Science.gov (United States)

    Spada, Nina; Jessop, Lorena; Tomita, Yasuyo; Suzuki, Wataru; Valeo, Antonella

    2014-01-01

    In this study we compared the effects of two types of form-focused instruction (FFI) on second language (L2) learning and their potential contributions to the development of different types of L2 knowledge. Both types of instruction were pre-emptive in nature, that is planned and teacher generated. In Integrated FFI attention to form was embedded…

  1. Particle-in-cell modeling for MJ scale dense plasma focus with varied anode shape

    Energy Technology Data Exchange (ETDEWEB)

    Link, A., E-mail: link6@llnl.gov; Halvorson, C., E-mail: link6@llnl.gov; Schmidt, A. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Hagen, E. C. [National Security Technologies, Las Vegas, NV 89030 (United States); Rose, D. V.; Welch, D. R. [Voss Scientific LLC, Albuquerque NM 87108 (United States)

    2014-12-15

    Megajoule scale dense plasma focus (DPF) Z-pinches with deuterium gas fill are compact devices capable of producing 10{sup 12} neutrons per shot but past predictive models of large-scale DPF have not included kinetic effects such as ion beam formation or anomalous resistivity. We report on progress of developing a predictive DPF model by extending our 2D axisymmetric collisional kinetic particle-in-cell (PIC) simulations from the 4 kJ, 200 kA LLNL DPF to 1 MJ, 2 MA Gemini DPF using the PIC code LSP. These new simulations incorporate electrodes, an external pulsed-power driver circuit, and model the plasma from insulator lift-off through the pinch phase. To accommodate the vast range of relevant spatial and temporal scales involved in the Gemini DPF within the available computational resources, the simulations were performed using a new hybrid fluid-to-kinetic model. This new approach allows single simulations to begin in an electron/ion fluid mode from insulator lift-off through the 5-6 μs run-down of the 50+ cm anode, then transition to a fully kinetic PIC description during the run-in phase, when the current sheath is 2-3 mm from the central axis of the anode. Simulations are advanced through the final pinch phase using an adaptive variable time-step to capture the fs and sub-mm scales of the kinetic instabilities involved in the ion beam formation and neutron production. Validation assessments are being performed using a variety of different anode shapes, comparing against experimental measurements of neutron yield, neutron anisotropy and ion beam production.

  2. Plasma process optimization for N-type doping applications

    Energy Technology Data Exchange (ETDEWEB)

    Raj, Deven; Persing, Harold; Salimian, Siamak; Lacey, Kerry; Qin Shu; Hu, Jeff Y.; McTeer, Allen [Applied Materials, Inc., Varian Semiconductor Business Unit, 35 Dory Road, Gloucester, MA 01930 (United States); Micron Technology, Inc., 8000 S. Federal Way, Boise, ID 83707 (United States)

    2012-11-06

    Plasma doping (PLAD) has been adopted across the implant technology space and into high volume production for both conventional DRAM and NAND doping applications. PLAD has established itself as an alternative to traditional ion implantation by beamline implantation. The push for high doping concentration, shallow doping depth, and conformal doping capability expand the need for a PLAD solution to meet such requirements. The unique doping profile and doping characteristics at high dose rates allow for PLAD to deliver a high throughput, differentiated solution to meet the demand of evolving transistor technology. In the PLAD process, ions are accelerated to the wafer as with a negative wafer bias applied to the wafer. Competing mechanisms, such as deposition, sputtering, and etching inherent in plasma doping require unique control and process optimization. In this work, we look at the distinctive process tool control and characterization features which enable an optimized doping process using n-type (PH{sub 3} or AsH{sub 3}) chemistries. The data in this paper will draw the relationship between process optimization through plasma chemistry study to the wafer level result.

  3. Effect of Wall Material on H– Production in a Plasma Sputter-Type Ion Source

    Directory of Open Access Journals (Sweden)

    Y. D. M. Ponce

    2004-12-01

    Full Text Available The effect of wall material on negative hydrogen ion (H– production was investigated in a multicusp plasma sputter-type ion source (PSTIS. Steady-state cesium-seeded hydrogen plasma was generated by a tungsten filament, while H– was produced through surface production using a molybdenum sputter target. Plasma parameters and H– yields were determined from Langmuir probe and Faraday cup measurements, respectively. At an input hydrogen pressure of 1.2 mTorr and optimum plasma discharge parameters Vd = –90 V and Id = –2.25 A, the plasma parameters ne was highest and T–e was lowest as determined from Langmuir probe measurements. At these conditions, aluminum generates the highest ion current density of 0.01697 mA/cm2, which is 64% more than the 0.01085 mA/cm2 that stainless steel produces. The yield of copper, meanwhile, falls between the two materials at 0.01164 mA/cm2. The beam is maximum at Vt = –125 V. Focusing is achieved at VL = –70 V for stainless steel, Vt = –60 V for aluminum, and Vt = –50 V for copper. The results demonstrate that proper selection of wall material can greatly enhance the H– production of the PSTIS.

  4. Damage threshold and focusability of mid-infrared free-electron laser pulses gated by a plasma mirror with nanosecond switching pulses

    CERN Document Server

    Wang, Xiaolong; Zen, Heishun; Kii, Toshiteru; Ohgaki, Hideaki

    2013-01-01

    The presence of a pulse train structure of an oscillator-type free-electron laser (FEL) results in the immediate damage of a solid target upon focusing. We demonstrate that the laser-induced damage threshold can be significantly improved by gating the mid-infrared (MIR) FEL pulses with a plasma mirror. Although the switching pulses we employ have a nanosecond duration which does not guarantee the clean wavefront of the gated FEL pulses, the high focusablity is experimentally confirmed through the observation of spectral broadening by a factor of 2.1 when we tightly focus the gated FEL pulses onto the Ge plate.

  5. The Optimal Conditions for Form-Focused Instruction: Method, Target Complexity, and Types of Knowledge

    Science.gov (United States)

    Kim, Jeong-eun

    2012-01-01

    This dissertation investigates optimal conditions for form-focused instruction (FFI) by considering effects of internal (i.e., timing and types of FFI) and external (i.e., complexity and familiarity) variables of FFI when it is offered within a primarily meaning-focused context of adult second language (L2) learning. Ninety-two Korean-speaking…

  6. Niemann-Pick type C: focus on the adolescent/adult onset form.

    Science.gov (United States)

    Di Lazzaro, Vincenzo; Marano, Massimo; Florio, Lucia; De Santis, Stefano

    2016-11-01

    Niemann-Pick disease type C (NP-C) is an inherited sphingolipidosis characterized by progressive neurological deterioration and early mortality. The symptomatology and disease progression of NP-C are markedly affected by the age at onset of neurological manifestations, and categorization into early-infantile, late-infantile, juvenile, adolescent/adult neurological onset forms can aid evaluation of disease course and responses to therapy. Here, we review current information on the detection, diagnosis, monitoring and treatment of NP-C, with a focus on the adolescent/adult-onset form. A recent analysis indicated that the combined incidence of NP-C related to NPC1 gene mutations (NPC1) and NP-C related to NPC2 gene mutations (NPC2) is approximately 1 case in every 89 000 live births. In particular, late-onset phenotypes might well provide a greater contribution to the overall incidence than has previously been reported. Some neuropathological features in NP-C are held in common with other advanced age-onset diseases such as Alzheimer's disease. Visceral symptoms such as splenomegaly are frequently asymptomatic in patients with adolescent/adult-onset NP-C, and are only occasionally detected during routine ultrasound assessments. In contrast, most patients with adolescent/adult-onset exhibit some degree of slowly progressive, non-disease-specific movement disorders (e.g. cerebellar ataxia), and/or more pathognomonic neurological signs such as vertical supranuclear gaze palsy. An increasing number of adolescent/adult-onset cases have been reported following initial recognition of cognitive impairment and/or psychiatric signs. The recent development and implementation of new clinical screening tools (e.g. the NP-C suspicion index) and biomarkers (e.g. plasma oxysterols) should help identify patients who warrant further investigation and possible treatment.

  7. Research on pinches driven by SPPED 2 generator hard X-ray and neutron emission in plasma focus configuration

    CERN Document Server

    Sánchez-Soto, L L; Silva, P; Sylvester, G S; Zambra, M; Pavez, C; Raspa, V; Castillo, F; Kies, W; Soto, Leopoldo; Moreno, Jose; Silva, Patricio; Sylvester, Gustavo; Zambra, Marcelo; Pavez, Cristian; Raspa, Veronica; Castillo, Fermin; Kies, Walter

    2004-01-01

    SPEED2 is a generator based on Marx technology and was designed in the University of Dusseldorf. SPEED2 consists on 40 +/- Marx modules connected in parallel (4.1 mF equivalent Marx generator capacity, 300 kV, 4 MA in short circuit, 187 kJ, 400 ns rise time, dI/dt~1013 A/s). Currently the SPEED2 is operating at the Comision Chilena de Energia Nuclear, CCHEN, Chile, being the most powerful and energetic device for dense transient plasma in the Southern Hemisphere. Most of the previous works developed in SPEED2 at Dusseldorf were done in a plasma focus configuration for soft X-ray emission and the neutron emission from SPEED2 was not completely studied. The research program at CCHEN considers experiments in different pinch configurations (plasma focus, gas puffed plasma focus, gas embedded Z-pinch, wire arrays) at current of hundred of kiloamperes to mega-amperes, using the SPEED2 generator. The Chilean operation has begun implementing and developing diagnostics in a conventional plasma focus configuration oper...

  8. Research on pinches driven by Speed-2 generator: Hard X-ray and neutron emission in plasma focus configuration

    Energy Technology Data Exchange (ETDEWEB)

    Soto, L.; Moreno, J.; Silva, P.; Sylvester, G.; Zambra, M.; Pavez, C. [Comision Chilena de Energia Nuclear, Santiago (Chile); Pavez, C. [Universidad de Concepcion (Chile); Raspa, V. [Buenos Aires Univ., PLADEMA, CONICET and INFIP (Argentina); Castillo, F. [Insitituto de Ciencias Nucleares, UNAM (Mexico); Kies, W. [Heinrich-Heine-Univ., Dusseldorf (Germany)

    2004-07-01

    Speed-2 is a generator based on Marx technology and was designed in the University of Dusseldorf. Speed-2 consists on 40 +/- Marx modules connected in parallel (4.1 {mu}F equivalent Marx generator capacity, 300 kV, 4 MA in short circuit, 187 kJ, 400 ns rise time, dI/dt {approx} 10{sup 13} A/s). Currently Speed-2 is operating at CCHEN (Chilean nuclear energy commission), being the most powerful and energetic device for dense transient plasma in the Southern Hemisphere. Most of the previous works developed in Speed-2 at Dusseldorf were done in a plasma focus configuration for soft X-ray emission and the neutron emission from Speed-2 was not completely studied. The research program at CCHEN considers experiments in different pinch configurations (plasma focus, gas puffed plasma focus, gas embedded Z-pinch, wire arrays) at current of hundred of kilo- to mega-amperes, using the Speed-2 generator. The Chilean operation has begun implementing and developing diagnostics in a conventional plasma focus configuration operating in deuterium in order to characterize the neutron emission and the hard X-ray production. Silver activation counters, plastics CR39 and scintillator-photomultiplier detectors are used to characterize the neutron emission. Images of metallic plates with different thickness are obtained on commercial radiographic film, Agfa Curix ST-G2, in order to characterize an effective energy of the hard X-ray outside of the discharge. (authors)

  9. Identification of type-2 phosphatidic acid phosphohydrolase (PAPH-2) in neutrophil plasma membranes.

    Science.gov (United States)

    Boder, E; Taylor, G; Akard, L; Jansen, J; English, D

    1994-11-01

    Plasma membrane phosphatidic acid phosphohydrolase (PAPH) plays an important role in signal transduction by converting phosphatidic acid to diacylglycerol. PAPH-2, a Mg(2+)-independent, detergent-dependent enzyme involved in cellular signal transduction, is reportedly absent from the plasma membranes of neutrophilic leukocytes, a cell that responds to metabolic stimulation with abundant phospholipase D-dependent diacylglycerol generation. The present study was designed to resolve this discrepancy, focusing on the influence of cellular disruption techniques, detergent availability and cation sensitivity on the apparent distribution of PAPH in neutrophil subcellular fractions. The results clearly indicate the presence of two distinct types of PAPH within the particulate and cytosolic fractions of disrupted cells. Unlike the cytosolic enzyme, the particulate enzymes was not potentiated by magnesium and was strongly detergent-dependent. The soluble and particulate enzymes displayed dissimilar pH profiles. Separation of neutrophil particulate material into fractions rich in plasma membranes, specific granules and azurophilic granules by high speed discontinuous density gradient centrifugation revealed that the majority of the particulate activity was confined to plasma membranes. This activity was not inhibited by pretreatment with n-ethyl-maleimide in concentrations as high as 25 mM. PAPH activity recovered in the cytosolic fraction of disrupted neutrophils was almost completely inhibited by 5.0 mM n-ethylmaleimide. We conclude that resting neutrophils possess n-ethylmaleimide-resistant PAPH (type 2) within their plasma membranes. This enzyme may markedly influence the kinetics of cell activation by metabolizing second messengers generated as a result of activation of plasma membrane phospholipase D.

  10. A new attempt using LabVIEW into a computational experiment of plasma focus device

    Science.gov (United States)

    Kim, Myungkyu

    2017-03-01

    The simulation program of plasma focus device based on S. Lee's model has been first developed since 30 years ago and it is widely used to date. Originally the program made by GWbasic language, and then modified by visual basic which was included in the Microsoft Excel. Using Excel well-known to researchers is a key advantage of this program. But it has disadvantages in displaying data in same graph, in slow calculation speed, and in displaying data and calculation of smaller time step. To overcome all these points, the LabVIEW that made by national instrument and based on graphical environment is used for simulation. Furthermore it is correlated with data acquisition of experiment, once experiment being the data is directly transferred to the simulation program and then analyzes and predicts for the next shot. The mass swept factor (fm) and current factor (fc) can be easily find out using this program. This paper describes the detail function and usage of the program and compares the results with the existing one.

  11. Nanofocus of tenth of joules and a portable plasma focus of few joules for field applications

    Science.gov (United States)

    Soto, Leopoldo; Pavéz, Cristian; Moreno, José; Tarifeño, Ariel; Pedreros, José; Altamirano, Luis

    2009-01-01

    A repetitive pinch plasma focus that works with stored energy less than 1 J per shot has be developed at the Chilean Nuclear Energy Commission. The main features of this device, repetitive Nanofocus, are 5 nF of capacity, 5 nH of inductance, 5-10 kV charging voltage, 60-250 mJ stored energy, 5-10 kA current peak, per shot. The device has been operated at 20 Hz in hydrogen and deuterium. X-ray radiographs of materials of different thickness were obtained. Neutrons were detected using a system based upon 3He proportional counter in chare integrated mode. However, the reproducibility of this miniaturized device is low and several technological subjects have to be previously solved in order to produce neutrons for periods greater than minutes. Further studies in the Nanofocus are being carried out. In addition, a device with a stored energy of a few joules is being explored. A preliminary compact, low weight (3 kg), portable PF device (25 cm×5 cm×5 cm) for field applications has been designed. This device was designed to operate with few kilovolts (10 kV or less) with a stored energy of 2 J and a repetition rate of 10 Hz without cooling. A neutron flux of the order of 104-105 n/s is expected.

  12. Development and experimental study of oil-free capacitor module for plasma focus device

    Science.gov (United States)

    Sharma, Ravindra Kumar; Sharma, Archana

    2017-03-01

    This development is concerned with the compact capacitor module for a plasma focus device. Oil-free, non-standard geometry capacitors are designed and developed for high current delivery in sub-microseconds time. Metalized dielectric film based pulse capacitor becomes progressively less viable at currents above 10 kA. It is due to reliability and energy scaling difficulties, based on effects such as vaporization, high resistivity, and end connection. Bipolar electrolytic capacitors are also not preferred due to their limited life and comparatively low peak current delivery. Bi-axially oriented polypropylene (BOPP) film with extended aluminum foil is a combination to deliver moderately high power. But, electrically weak points, relative permittivity, and the edge gap margins have made its adoption difficult. A concept has been developed in lab for implementing the above combination in a less complex and costly manner. This paper concerns the development and testing process techniques for quite different hollow cylindrical, oil-free capacitors (4 μ F , 10 kV, 20 nH). Shot life of 1000 has been experimentally performed on the test bed at its rated energy density level. The technological methods and engineering techniques are now available and utilized for manufacturing and testing of BOPP film based oil-free capacitors.

  13. In situ determination of the static inductance and resistance of a plasma focus capacitor bank.

    Science.gov (United States)

    Saw, S H; Lee, S; Roy, F; Chong, P L; Vengadeswaran, V; Sidik, A S M; Leong, Y W; Singh, A

    2010-05-01

    The static (unloaded) electrical parameters of a capacitor bank are of utmost importance for the purpose of modeling the system as a whole when the capacitor bank is discharged into its dynamic electromagnetic load. Using a physical short circuit across the electromagnetic load is usually technically difficult and is unnecessary. The discharge can be operated at the highest pressure permissible in order to minimize current sheet motion, thus simulating zero dynamic load, to enable bank parameters, static inductance L(0), and resistance r(0) to be obtained using lightly damped sinusoid equations given the bank capacitance C(0). However, for a plasma focus, even at the highest permissible pressure it is found that there is significant residual motion, so that the assumption of a zero dynamic load introduces unacceptable errors into the determination of the circuit parameters. To overcome this problem, the Lee model code is used to fit the computed current trace to the measured current waveform. Hence the dynamics is incorporated into the solution and the capacitor bank parameters are computed using the Lee model code, and more accurate static bank parameters are obtained.

  14. Revisiting Plant Plasma Membrane Lipids in Tobacco: A Focus on Sphingolipids.

    Science.gov (United States)

    Cacas, Jean-Luc; Buré, Corinne; Grosjean, Kevin; Gerbeau-Pissot, Patricia; Lherminier, Jeannine; Rombouts, Yoann; Maes, Emmanuel; Bossard, Claire; Gronnier, Julien; Furt, Fabienne; Fouillen, Laetitia; Germain, Véronique; Bayer, Emmanuelle; Cluzet, Stéphanie; Robert, Franck; Schmitter, Jean-Marie; Deleu, Magali; Lins, Laurence; Simon-Plas, Françoise; Mongrand, Sébastien

    2016-01-01

    The lipid composition of plasma membrane (PM) and the corresponding detergent-insoluble membrane (DIM) fraction were analyzed with a specific focus on highly polar sphingolipids, so-called glycosyl inositol phosphorylceramides (GIPCs). Using tobacco (Nicotiana tabacum) 'Bright Yellow 2' cell suspension and leaves, evidence is provided that GIPCs represent up to 40 mol % of the PM lipids. Comparative analysis of DIMs with the PM showed an enrichment of 2-hydroxylated very-long-chain fatty acid-containing GIPCs and polyglycosylated GIPCs in the DIMs. Purified antibodies raised against these GIPCs were further used for immunogold-electron microscopy strategy, revealing the distribution of polyglycosylated GIPCs in domains of 35 ± 7 nm in the plane of the PM. Biophysical studies also showed strong interactions between GIPCs and sterols and suggested a role for very-long-chain fatty acids in the interdigitation between the two PM-composing monolayers. The ins and outs of lipid asymmetry, raft formation, and interdigitation in plant membrane biology are finally discussed.

  15. Low-Energy Plasma Focus as a Tailored X-Ray Source

    Science.gov (United States)

    Zakaullah, M.; Alamgir, K.; Shafiq, M.; Sharif, M.; Waheed, A.; Murtaza, G.

    2000-06-01

    A low-energy (2.3 kJ) plasma focus energized by a single 32-μF capacitor charged at 12 kV with filling gases hydrogen, neon, and argon is investigated as an X-ray source. Experiments are conducted with a copper and an aluminum anode. Specifically, attention is given to tailoring the radiation in different windows, e.g., 1.2-1.3 keV, 1.3-1.5 keV, 2.5-5 keV, and Cu-Kα line radiation. The highest X-ray emission is observed with neon filling and the copper anode in the 1.2-1.3 keV window, which we speculate to be generated due to recombination of hydrogenlike neon ions with a few eV to a few 10s of eV electrons. The wall-plug efficiency of the device is found to be 4%. The other significant emission occurs with hydrogen filling, which exhibits wall-plug efficiency of 1.7% for overall X-ray emission and 0.35% for Cu-Kα line radiation. The emission is dominated by the interaction of electrons in the current sheath with the anode tip. The emission with the aluminum anode and hydrogen filling is up to 10 J, which corresponds to wall-plug efficiency of 0.4%. The X-ray emission with argon filling is less significant.

  16. Self-Similar Nonlinear Dynamical Solutions for One-Component Nonneutral Plasma in a Time-Dependent Linear Focusing Field

    Energy Technology Data Exchange (ETDEWEB)

    Hong Qin and Ronald C. Davidson

    2011-07-19

    In a linear trap confining a one-component nonneutral plasma, the external focusing force is a linear function of the configuration coordinates and/or the velocity coordinates. Linear traps include the classical Paul trap and the Penning trap, as well as the newly proposed rotating-radio- frequency traps and the Mobius accelerator. This paper describes a class of self-similar nonlinear solutions of nonneutral plasma in general time-dependent linear focusing devices, with self-consistent electrostatic field. This class of nonlinear solutions includes many known solutions as special cases.

  17. Research of the Effects of Electron Focused Electric Field upon an Enhanced Glow Discharge Plasma Ion Implantation

    Institute of Scientific and Technical Information of China (English)

    LI Liu-he; WU Yong-qin; ZHANG Yan-hua; CAI Xun; CHU Paul K

    2004-01-01

    A new Enhanced Glow Discharge Plasma Ion Implantation methods are introduced, in which the plasma are produced by the self glow discharge excitated by high negative voltage bias. The electric field is designed to a electron focusing mode by using a small area hollow anode and a large area sample holder cathode. The pattern of equipotentials of the electric field are calculated through finite-element method. By using the special electron-focusing field, the self glow discharge are enhanced and provide denser ions to implanted into the substrate.

  18. Exploring types of focused factories in hospital care: a multiple case study.

    Science.gov (United States)

    Bredenhoff, Eelco; van Lent, Wineke A M; van Harten, Wim H

    2010-06-07

    Focusing on specific treatments or diseases is proposed as a way to increase the efficiency of hospital care. The definition of "focus" or "focused factory", however, lacks clarity. Examples in health care literature relate to very different organizations.Our aim was to explore the application of the focused factory concept in hospital care, including an indication of its performance, resulting in a conceptual framework that can be helpful in further identifying different types of focused factories. Thus contributing to the understanding of the diversity of examples found in the literature. We conducted a cross-case comparison of four multiple-case studies into hospital care. To cover a broad array of focus, different specialty fields were selected. Each study investigated the organizational context, the degree of focus, and the operational performance. Focus was measured using an instrument translated from industry. Data were collected using both qualitative and quantitative methods and included site visits. A descriptive analysis was performed at the case study and cross-case studies level. The operational performance per specialty field varied considerably, even when cases showed comparable degrees of focus. Cross-case comparison showed three focus domains. The product domain considered specialty based focused factories that treated patients for a single-specialty, but did not pursue a specific strategy nor adapted work-designs or layouts. The process domain considered delivery based focused factories that treated multiple groups of patients and often pursued strategies to improve efficiency and timeliness and adapted work-designs and physical layouts to minimize delays. The product-process domain considered procedure based focused factories that treated a single well-defined group of patients offering one type of treatment. The strategic focusing decisions and the design of the care delivery system appeared especially important for delivery and procedure based

  19. Exploring types of focused factories in hospital care: a multiple case study

    Directory of Open Access Journals (Sweden)

    van Lent Wineke AM

    2010-06-01

    Full Text Available Abstract Background Focusing on specific treatments or diseases is proposed as a way to increase the efficiency of hospital care. The definition of "focus" or "focused factory", however, lacks clarity. Examples in health care literature relate to very different organizations. Our aim was to explore the application of the focused factory concept in hospital care, including an indication of its performance, resulting in a conceptual framework that can be helpful in further identifying different types of focused factories. Thus contributing to the understanding of the diversity of examples found in the literature. Methods We conducted a cross-case comparison of four multiple-case studies into hospital care. To cover a broad array of focus, different specialty fields were selected. Each study investigated the organizational context, the degree of focus, and the operational performance. Focus was measured using an instrument translated from industry. Data were collected using both qualitative and quantitative methods and included site visits. A descriptive analysis was performed at the case study and cross-case studies level. Results The operational performance per specialty field varied considerably, even when cases showed comparable degrees of focus. Cross-case comparison showed three focus domains. The product domain considered specialty based focused factories that treated patients for a single-specialty, but did not pursue a specific strategy nor adapted work-designs or layouts. The process domain considered delivery based focused factories that treated multiple groups of patients and often pursued strategies to improve efficiency and timeliness and adapted work-designs and physical layouts to minimize delays. The product-process domain considered procedure based focused factories that treated a single well-defined group of patients offering one type of treatment. The strategic focusing decisions and the design of the care delivery system

  20. Social support sources, types, and generativity: a focus group study of cancer survivors and their caregivers.

    Science.gov (United States)

    Wong, Alison G; Ki, Ppudah; Maharaj, Artie; Brown, Edna; Davis, Cindy; Apolinsky, Felice

    2014-01-01

    Various research studies have identified the sources and types of support that people with cancer receive; however, few have focused on identifying the specific characteristics of emotional, instrumental, and informational support. In this study, focus groups consisting of Gilda's Club members explored the types of support that people with cancer and their caregivers experienced and valued. Results showed that although men and women with cancer and caregivers identify similar sources of support, they experience different types of support. Results also indicated a desire among participants to help and support others, a concept referred to as generativity. Implications for social workers and health care providers are explored.

  1. Sex differences in type 2 diabetes: focus on disease course and outcomes

    Directory of Open Access Journals (Sweden)

    Arnetz L

    2014-09-01

    Full Text Available Lisa Arnetz,1,2 Neda Rajamand Ekberg,1,2 Michael Alvarsson1,2 1Department of Molecular Medicine and Surgery, Karolinska Institutet, 2Department of Endocrinology, Metabolism and Diabetes, Stockholm, Sweden Background: Women with type 2 diabetes (T2D are less likely to reach the goals for hemoglobin A1c compared with men, and have higher all-cause mortality. The risk of cardiovascular disease is elevated among both men and women with T2D, however, the risk has declined among men over recent years while it remains stationary in women. Reasons for these sex differences remain unclear, and guidelines for diabetes treatment do not differentiate between sexes. Possible causes for varying outcome include differences in physiology, treatment response, and psychological factors. This review briefly outlines sex differences in hormonal pathophysiology, and thereafter summarizes the literature to date on sex differences in disease course and outcome. Methods: Systematic searches were performed on PubMed using “sex”, “gender”, and various glucose-lowering therapies as keywords. Earlier reviews are summarized and results from individual studies are reported. Reference lists from studies were used to augment the search. Results: There is an increased risk of missing the diagnosis of T2D when screening women with only fasting plasma glucose instead of with an oral glucose tolerance test. The impact of various risk factors for complications may differ by sex. Efficacy and side effects of some glucose-lowering drugs differ between men and women. Men with T2D appear to suffer more microvascular complications, while women have higher morbidity and mortality in cardiovascular disease and also fare worse psychologically. Conclusion: Few studies to date have focused on sex differences in T2D. Several questions demand further study, such as whether risk factors and treatment guidelines should be sex-specific. There is a need for clinical trials designed

  2. Optical emission spectroscopy of deuterium and helium plasma jets emitted from plasma focus discharges at the PF-1000U facility

    Science.gov (United States)

    Skladnik-Sadowska, E.; Dan'ko, S. A.; Kwiatkowski, R.; Sadowski, M. J.; Zaloga, D. R.; Paduch, M.; Zielinska, E.; Kharrasov, A. M.; Krauz, V. I.

    2016-12-01

    Optical emission spectroscopy techniques were used to investigate the spectra of dense deuterium-plasma jets generated by high-current pulse discharges within the large PF-1000U facility and to estimate parameters of plasma inside the jets and their surroundings. Time-resolved optical spectra were recorded by means of a Mechelle®900 spectrometer. From an analysis of the deuterium line broadening, it was estimated that the electron concentration at a distance 57 cm from the electrode outlets amounted to (0.4-3.7) × 1017 cm-3 depending on the initial gas distribution and the time interval of the spectrum registration after the instant of the plasma jet generation. From the re-absorption dip in the Dβ profile, it was assessed that the electron concentration in the surrounding gas was equal to about 1.5 × 1015 cm-3. On the basis of the measured ratio of He II 468.6 nm and He I 587.6 nm line intensities, it was estimated that the electron temperature amounted to about 5.3 eV. Also estimated were some dimensionless parameters of the investigated plasma jets.

  3. Ion beam extraction from a matrix ECR plasma source by discrete ion-focusing effect

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, Mihai

    2010-01-01

    Positive or negative ion beams extracted from plasma are used in a large variety of surface functionalization techniques such as implantation, etching, surface activation, passivation or oxidation. Of particular importance is the surface treatment of materials sensitive to direct plasma exposure ...

  4. Enhanced relativistic self-focusing of Hermite-cosh-Gaussian laser beam in plasma under density transition

    Energy Technology Data Exchange (ETDEWEB)

    Nanda, Vikas; Kant, Niti, E-mail: nitikant@yahoo.com [Department of Physics, Lovely Professional University, Phagwara 144411, Punjab (India)

    2014-04-15

    Enhanced and early relativistic self-focusing of Hermite-cosh-Gaussian (HChG) beam in the plasmas under density transition has been investigated theoretically using Wentzel-Kramers-Brillouin and paraxial ray approximation for mode indices m=0, 1, and 2. The variation of beam width parameter with normalized propagation distance for m=0, 1, and 2 is reported, and it is observed that strong self-focusing occurs as the HChG beam propagates deeper inside the nonlinear medium as spot size shrinks due to highly dense plasmas and the results are presented graphically. A comparative study between self-focusing of HChG beam in the presence and absence of plasmas density transition is reported. The dependency of beam width parameter on the normalized propagation distance for different values of decentered parameter “b” has also been presented graphically. For m=0 and 1, strong self-focusing is reported for b=1.8, and for m=2 and b=1.8, beam gets diffracted. The results obtained indicate the dependency of the self-focusing of the HChG beam on the selected values of decentered parameter. Moreover, proper selection of decentered parameter results strong self-focusing of HChG beam. Stronger self-focusing of laser beam is observed due to the presence of plasma density transition which might be very useful in the applications like the generation of inertial fusion energy driven by lasers, laser driven accelerators, etc.

  5. The role of the gas/plasma plume and self-focusing in a gas-filled capillary discharge waveguide for high-power laser-plasma applications

    CERN Document Server

    Ciocarlan, C.; Islam, M. R.; Ersfeld, B.; Abuazoum, S.; Wilson, R.; Aniculaesei, C.; Welsh, G. H.; Vieux, G.; Jaroszynski, D. A.; 10.1063/1.4822333

    2013-01-01

    The role of the gas/plasma plume at the entrance of a gas-filled capillary discharge plasma waveguide in increasing the laser intensity has been investigated. Distinction is made between neutral gas and hot plasma plumes that, respectively, develop before and after discharge breakdown. Time-averaged measurements show that the on-axis plasma density of a fully expanded plasma plume over this region is similar to that inside the waveguide. Above the critical power, relativistic and ponderomotive selffocusing lead to an increase in the intensity, which can be nearly a factor of 2 compared with the case without a plume. When used as a laser plasma wakefield accelerator, the enhancement of intensity can lead to prompt electron injection very close to the entrance of the waveguide. Self-focusing occurs within two Rayleigh lengths of the waveguide entrance plane in the region, where the laser beam is converging. Analytical theory and numerical simulations show that, for a density of 3.01018 cm3, the peak normalized...

  6. Plasma apolipoprotein A5 and triglycerides in type 2 diabetes

    NARCIS (Netherlands)

    Dallinga-Thie, GM; Van Tol, A; Hattori, H; van Vark-van de Zee, LC; Jansen, H; Sijbrands, EJG

    Aims/hypothesis: Variation in the human apolipoprotein (APO) A5 gene (APOA5) is associated with elevated plasma triglycerides. However, data on the exact role of plasma concentrations of APOA5 in human triglyceride homeostasis are lacking. In the present study, we estimated plasma APOA5 levels in

  7. Plasma apolipoprotein A5 and triglycerides in type 2 diabetes

    NARCIS (Netherlands)

    Dallinga-Thie, GM; Van Tol, A; Hattori, H; van Vark-van de Zee, LC; Jansen, H; Sijbrands, EJG

    2006-01-01

    Aims/hypothesis: Variation in the human apolipoprotein (APO) A5 gene (APOA5) is associated with elevated plasma triglycerides. However, data on the exact role of plasma concentrations of APOA5 in human triglyceride homeostasis are lacking. In the present study, we estimated plasma APOA5 levels in pa

  8. Study of Magnetic Field Behavior at Lower Pressure of Neon in the Axial Phase of INTI Plasma Focus

    Directory of Open Access Journals (Sweden)

    K.K.A. Devi

    2014-03-01

    Full Text Available The magnetic field distribution substantially affects mechanisms for the generation of radiation in Z-pinches. Investigation of the axial component of the magnetic field is one of the important problems in plasma focus studies. The designed magnetic probe is intended to use for the study of current sheet in INTI plasma focus device with energy of about 3.3 kJ. The measurements of the azimuthal component of the magnetic field on the INTI Plasma Focus operated at neon pressures below 1 Torr was carried out using a custom built calibrated magnetic probe. The probe was tested for neon gas under the various lower pressures (i.e., 0.1, 0.3, 0.5 and 0.7, 1, 2, 3, 5 torr etc.. It is observed that the time response of the designed probe is sufficient for the rise time of the magnetic field associated with the current in the axial phase. We also note that the small size of the designed probe is well suited to sense the magnetic field without perturbing the plasma unduly. The probe designed and constructed is also suitable to carryout measurements to obtain axial distributions of trajectory, average axial velocity and magnetic field of the current sheath at a certain radial distances along the axis of the tube.

  9. Soft X-ray Emission Optimization Studies with Krypton and Xenon Gases in Plasma Focus Using Lee Model

    Science.gov (United States)

    Akel, Mohamad

    2013-10-01

    The X-ray emission properties of krypton and xenon plasmas are numerically investigated using corona plasma equilibrium model. Numerical experiments have been investigated on various low energy plasma focus devices with Kr and Xe filling gases using Lee model. The Lee model was applied to characterize and to find the optimum combination of soft X-ray yields (Ysxr) for krypton (~4 Å) and xenon (~3 Å) plasma focus. These combinations give Ysxr = 0.018 J for krypton, and Ysxr = 0.5 J for xenon. Scaling laws on Kr and Xe soft X-ray yields, in terms of storage energies E0, peak discharge current Ipeak and focus pinch current Ipinch were found over the range from 2.8 to 900 kJ. Soft X-ray yields scaling laws in terms of storage energies were found to be as and for Kr and Xe, respectively, (E0 in kJ and Ysxr in J) with the scaling showing gradual deterioration as E0 rises over the range. The maximum soft X-ray yields are found to be about 0.5 and 27 J from krypton and xenon, respectively, for storage energy of 900 kJ. The optimum efficiencies for soft X-ray yields (0.0002 % for Kr) and (0.0047 % for Xe) are with capacitor bank energies of 67.5 and 225 kJ, respectively.

  10. Nanofocus: an ultra-miniature dense pinch plasma focus device with submillimetric anode operating at 0.1 J

    Energy Technology Data Exchange (ETDEWEB)

    Soto, Leopoldo; Pavez, Cristian; Moreno, Jose [Comision Chilena de Energia Nuclear, Casilla 188-D, Santiago (Chile); Barbaglia, Mario; Clausse, Alejandro [CNEA-CONICET and Universidad Nacional del Centro, 7000 Tandil (Argentina)], E-mail: lsoto@cchen.cl

    2009-02-01

    As a method for investigating the minimum energy to produce a pinch plasma focus (PF) discharge, an ultra-miniature device for pinch discharges has been designed, constructed and characterized (nanofocus (NF): 5 nF, 5-10 kV, 5-10 kA, 60-250 mJ, 16 ns time to peak current). Submillimetric anode radii (0.8 and 0.21 mm) covered by coaxial insulators were used for experiments in hydrogen. Evidence of pinch was observed in electrical signals in discharges operating at 3 mbar and {approx}100 mJ. A single-frame image converter camera (4 ns exposure) was used to obtain plasma images in the visible range. The dynamics observed from the photographs is consistent with (a) the formation of a plasma sheath close to the insulator surface, (b) the plasma covering the anode, (c) radial compression over the anode; (d) finally the plasma is detached from the anode in the axial direction. The total time from stages (a) to (d) was observed in {approx}30 ns. This ultra-miniature device has a value for the 'plasma energy density parameter' and for the 'drive parameter' of the same order or greater than PF devices operating at energies several orders of magnitude higher.

  11. Laser-optical measurements of the velocities of the plasma jets formed from different gases in a kilojoule-range plasma focus facility

    Energy Technology Data Exchange (ETDEWEB)

    Polukhin, S. N., E-mail: snpol@lebedev.ru; Dzhamankulov, A. M.; Gurei, A. E.; Nikulin, V. Ya., E-mail: vnik@lebedev.ru; Peregudova, E. N.; Silin, P. V. [Russian Academy of Sciences, Lebedev Physical Institute (Russian Federation)

    2016-12-15

    The velocities of the plasma jets formed from Ne, N{sub 2}, Ar, and Xe gases in plasma focus facilities were determined by means of laser-optical shadowgraphy of the shock waves generated at the jet leading edge. In spite of the almost tenfold ratio between the atomic weights of these gases, the outflow velocities of the plasma jets formed in experiments with these gases differ by less than twice, in the range of (0.7–1.1) × 10{sup 7} cm/s under similar discharge conditions. The energies of the jet ions were found to vary from 0.7 keV for nitrogen to 4 keV for xenon.

  12. Development of Diagnostics for Large-Scale Experiments with Dense Magnetized Plasmas - MJ Plasma-focus diagnostics systems

    Energy Technology Data Exchange (ETDEWEB)

    Scholz, M.; Karpinski, L.; Paduch, M.; Pisarczyk, T.; Zielinska, E.; Chodukowski, T. [Institute of Plasma Physics and Laser Microfusion IPPLM, 01-497 Warsaw (Poland); Sadowski, M.J. [Institute of Plasma Physics and Laser Microfusion IPPLM, 01-497 Warsaw (Poland)] [The Andrzej Soltan Institute for Nuclear Studies IPJ, 05-400 Otwock-Swiert (Poland); Skladnik-Sadowska, E.; Czaus, K.; Kwiatkowski, R.; Malinowski, K. [The Andrzej Soltan Institute for Nuclear Studies IPJ, 05-400 Otwock-Swiert (Poland); Krauz, S. [RNC Kurchatov Institute, Moscow (Russian Federation); Mitrovanov, K. [FGUP GNC RF Triniti, Troick (Russian Federation)

    2011-07-01

    This document presents the diagnostics arrangements and interesting results of research on fusion pulsed plasma, which was generated within the large PF-1000 facility operated in the Institute of Plasma Physics and Laser Microfusion (Warsaw, Poland). Experimental studies were carried out with the following diagnostic techniques: 1) Rogovski coil for current measurements; 2) Four dI/dt probes in different places around the collector of PF-1000; 3) Voltage divider; 4) Mach-Zender interferometer (16 frames); 5) Fast scintillation probes for X-ray and neutron detection; 6) Silver activation counters; 7) Specially prepared current probes; 8) Thomson spectrometer for mass- and energy-analysis of deuterium beams; 9) Ion-pinhole cameras equipped with nuclear-track detectors, etc. The studies have been carried out with the pure deuterium filling, and particular attention was paid to correlations between the fast-neutron emission and an evolution of plasma parameters. The total fusion-neutron yield, as measured with four silver-activation counters, was found to be up to 7*10{sup 11} per shot, depending on the experimental conditions. Correlations of the neutron pulses with interferometric frame-pictures of the PF pinch column were studied. From time-of-flight (ToF) measurements of the fusion neutrons it was possible to estimate a CM velocity of deuterons involved in the D-D reactions. The fast fusion-produced protons have also been recorded and analyzed by means pinhole cameras and shielded track detectors. The document is composed of an abstract followed by the slides of the presentation. (authors)

  13. Research on soft x-rays in high-current plasma-focus discharges and estimation of plasma electron temperature

    Science.gov (United States)

    Skladnik-Sadowska, E.; Zaloga, D.; Sadowski, M. J.; Kwiatkowski, R.; Malinowski, K.; Miklaszewski, R.; Paduch, M.; Surala, W.; Zielinska, E.; Tomaszewski, K.

    2016-09-01

    The paper presents results of experimental studies of dense and high-temperature plasmas, which were produced by pulsed high-current discharges within a modernised PF-1000U facility operated at different initial gas conditions, and supplied from a condenser bank which delivered energy of about 350 kJ. The investigated discharges were performed at the initial deuterium filling under pressure of 1.6-2.0 hPa, with or without an additional puffing of pure deuterium (1 cm3, under pressure 0.15 MPa, at instants 1.5-2 ms before the main discharge initiation). For a comparison discharges were also performed at the initial neon filling under pressure of 1.1-1.3 hPa, with or without the addition of deuterium puffing. The recorded discharge current waveforms, laser interferometric images, signals of hard x-rays and fusion neutrons, as well as time-integrated x-ray pinhole images and time-resolved x-ray signals were compared. From a ratio of the x-ray signals recorded behind beryllium filters of different thickness there were estimated values of a plasma electron temperature (T e) in a region at the electrode outlets. For pure deuterium discharges an averaged T e value amounted to 150-170 eV, while for neon discharges with the deuterium puffing it reached 330-880 eV (with accuracy of  ±20%).

  14. Influence of the Al wire placed in the anode axis on the transformation of the deuterium plasma column in the plasma focus discharge

    Science.gov (United States)

    Kubes, P.; Paduch, M.; Cikhardtova, B.; Cikhardt, J.; Klir, D.; Kravarik, J.; Rezac, K.; Zielinska, E.; Zaloga, D.; Sadowski, M. J.; Tomaszewski, K.

    2016-06-01

    In this paper, we describe the influence of an Al wire of 270 μm in diameter placed along the anode axis on the transformation of the deuterium pinch column in a megaampere (MA) plasma focus device. The evolution of the pinched column and of the wire corona was investigated by means of the multiframe interferometry, neutron and X-ray diagnostics. The wire corona did not influence considerably on the evolution of dense plasma structures and neutron production, but it increased the plasma density and consequently, the currents around its surface. The distribution of the closed internal currents (ranging hundreds of kA) and associated magnetic fields amounting to 5 T were also estimated in the dense plasma column and in plasmoidal structures at the near-equilibrium state. The description is based on the balance of the plasma pressure and the pressure of the internal poloidal and toroidal current components compressed by the external pinched column. The dominant number of fusion deuterium-deuterium (D-D) neutrons is produced during the evolution of instabilities, when the uninterrupted wire corona (containing deuterium) connects the dense structures of the pinch, and it did not allow the formation of a constriction of the sub-millimeter diameter.

  15. Dense Plasma Focus: physics and applications (radiation material science, single-shot disclosure of hidden illegal objects, radiation biology and medicine, etc.)

    Science.gov (United States)

    Gribkov, V. A.; Miklaszewski, R.; Paduch, M.; Zielinska, E.; Chernyshova, M.; Pisarczyk, T.; Pimenov, V. N.; Demina, E. V.; Niemela, J.; Crespo, M.-L.; Cicuttin, A.; Tomaszewski, K.; Sadowski, M. J.; Skladnik-Sadowska, E.; Pytel, K.; Zawadka, A.; Giannini, G.; Longo, F.; Talab, A.; Ul'yanenko, S. E.

    2015-03-01

    The paper presents some outcomes obtained during the year of 2013 of the activity in the frame of the International Atomic Energy Agency Co-ordinated research project "Investigations of Materials under High Repetition and Intense Fusion-Relevant Pulses". The main results are related to the effects created at the interaction of powerful pulses of different types of radiation (soft and hard X-rays, hot plasma and fast ion streams, neutrons, etc. generated in Dense Plasma Focus (DPF) facilities) with various materials including those that are counted as perspective ones for their use in future thermonuclear reactors. Besides we discuss phenomena observed at the irradiation of biological test objects. We examine possible applications of nanosecond powerful pulses of neutrons to the aims of nuclear medicine and for disclosure of hidden illegal objects. Special attention is devoted to discussions of a possibility to create extremely large and enormously diminutive DPF devices and probabilities of their use in energetics, medicine and modern electronics.

  16. Self-focusing of coaxial electromagnetic beams in a plasma with electron temperature dependent electron-ion recombination coefficient

    Science.gov (United States)

    Misra, Shikha; Sodha, M. S.; Mishra, S. K.

    2017-02-01

    An analytical formulation, describing the propagation of multiple coaxial Gaussian electromagnetic (em) beams in a self-formed plasma channel with dominant collisional nonlinearity has been developed; the generation/recombination of high energy plasma particles has been considered as an additional source of plasma non-linearity in addition to Ohmic heating. Well versed paraxial approach in the vicinity of the intensity maximum has been adopted to solve the wave equation and examine the non-linear propagation of em beams while the dielectric function in the presence of the em field is determined from the balance of partial pressure gradient of electron/ion gas with the space charge field and energy balance of plasma particles. On the basis of the analysis the influence of this novel non-linearity on the propagation features like electron temperature, dielectric function and critical curves are derived numerically and graphically presented. The inclusion of this novel nonlinearity results in reduced focusing effect. The three regime characteristic features viz. oscillatory focusing/defocusing and steady divergence of beam propagation have also been worked out.

  17. The Effect of Driver Rise-Time on Pinch Current and its Impact on Plasma Focus Performance and Neutron Yield

    Science.gov (United States)

    Sears, Jason; Schmidt, Andrea; Link, Anthony; Welch, Dale

    2016-10-01

    Experiments have suggested that dense plasma focus (DPF) neutron yield increases with faster drivers [Decker NIMP 1986]. Using the particle-in-cell code LSP [Schmidt PRL 2012], we reproduce this trend in a kJ DPF [Ellsworth 2014], and demonstrate how driver rise time is coupled to neutron output. We implement a 2-D model of the plasma focus including self-consistent circuit-driven boundary conditions. Driver capacitance and voltage are varied to modify the current rise time, and anode length is adjusted so that run-in coincides with the peak current. We observe during run down that magnetohydrodynamic (MHD) instabilities of the sheath shed blobs of plasma that remain in the inter-electrode gap during run in. This trailing plasma later acts as a low-inductance restrike path that shunts current from the pinch during maximum compression. While the MHD growth rate increases slightly with driver speed, the shorter anode of the fast driver allows fewer e-foldings and hence reduces the trailing mass between electrodes. As a result, the fast driver postpones parasitic restrikes and maintains peak current through the pinch during maximum compression. The fast driver pinch therefore achieves best simultaneity between its ion beam and peak target density, which maximizes neutron production. Prepared by LLNL under Contract DE-AC52-07NA27344.

  18. Dynamics of plasma formation and permanent structural transformation in ZBLAN excited by tightly focused femtosecond laser pulses

    Science.gov (United States)

    Cho, Sung-Hak; Chang, Won-Seok; Kim, Kwang-Ryul; Hong, Jong Wook

    2009-01-01

    Time-resolved dynamics of plasma formation and bulk refractive-index modification in fluoride glass (ZBLAN) excited by a tightly focused femtosecond (130 fs) Ti:sapphire laser ( λp=790 nm) was observed in situ. The femtosecond time-resolved pump-probe measurement with perpendicularly linear polarized beams was used to study the dynamics of both plasma formation and induced permanent structural transformation with refractive-index change. In the refractive-index domain, the lifetime of induced plasma formation is ˜35 ps and structural transition time for forming the refractive-index change is ˜80 ps. In the optical damage domain, however, the lifetime of induced plasma formation is ˜40 ps and structural transition time for forming the optical damage is ˜140 ps. We found that the process of refractive-index bulk modification is significantly different from that of optical cracks. From the diffraction efficiency of Kogelnik's coupled mode theory, the maximum value of refractive-index change (Δ n) was estimated to be 1.3×10 -2. By the scanning of fluoride glass on the optical X-Y-Z stages, the fabrication of internal grating with refractive-index modification was demonstrated in fluoride glass using tightly focused femtosecond laser.

  19. Using FLUKA to Study Concrete Square Shield Performance in Attenuation of Neutron Radiation Produced by APF Plasma Focus Neutron Source

    Science.gov (United States)

    Nemati, M. J.; Habibi, M.; Amrollahi, R.

    2013-04-01

    In 2010, representatives from the Nuclear Engineering and physics Department of Amirkabir University of Technology (AUT) requested development of a project with the objective of determining the performance of a concrete shield for their Plasma Focus as neutron source. The project team in Laboratory of Nuclear Engineering and physics department of Amirkabir University of Technology choose some shape of shield to study on their performance with Monte Carlo code. In the present work, the capability of Monte Carlo code FLUKA will be explored to model the APF Plasma Focus, and investigating the neutron fluence on the square concrete shield in each region of problem. The physical models embedded in FLUKA are mentioned, as well as examples of benchmarking against future experimental data. As a result of this study suitable thickness of concrete for shielding APF will be considered.

  20. FePt nanoparticle formation with lower phase transition temperature by single shot plasma focus ion irradiation

    Science.gov (United States)

    Lin, J. J.; Roshan, M. V.; Pan, Z. Y.; Verma, R.; Lee, P.; Springham, S. V.; Tan, T. L.; Rawat, R. S.

    2008-07-01

    Uniform FePt nanoparticles were synthesized through nanostructuring of pulsed laser deposited FePt thin films by single shot H+ ion irradiation using a plasma focus device. The annealing temperature required for phase transition from low Ku face-centred cubic to high Ku face-centred tetragonal, for ion irradiated samples, is simultaneously lowered down to 400 °C. The energetic H+ ion irradiation significantly reduces the activation energy for atomic ordering by increasing the number of vacancies. The advantage of using a plasma focus device is that it can achieve nanostructuring in much shorter time, in single shot ion exposure with pulse duration of typically about a few hundreds of nanoseconds, as compared with much longer duration required by continuous ion sources.

  1. Effect of Higher Order Axial Electron Temperature on Self-Focusing of Electromagnetic Pulsed Beam in Collisional Plasma

    Institute of Scientific and Technical Information of China (English)

    夏雄平; 易林

    2012-01-01

    Effect of higher order axial electron temperature on self-focusing of electromagnetic pulsed beam in collisional plasma is investigated.It is shown that higher order axial electron temperature T p4 is not trivial than T p0 and T p2,which can modify slightly radial redistribution of electron density and increases effective dielectric constant.As a result,on one hand,slightly reduce electromagnetic beam self-focusing in the course of oscillatory convergence,on the other hand,quicken beam divergence in the course of steady divergence,i.e.,higher order axial electron temperature T p4 can decrease the influence of collisional nonlinearity in collisional plasma.

  2. Effects of relativistic and channel focusing on q-Gaussian laser beam propagating in a preformed parabolic plasma channel

    Science.gov (United States)

    Wang, Li; Hong, Xue-Ren; Sun, Jian-An; Tang, Rong-An; Yang, Yang; Zhou, Wei-Jun; Tian, Jian-Min; Duan, Wen-Shan

    2017-07-01

    The propagation of q-Gaussian laser beam in a preformed plasma channel is investigated by means of the variational method. A differential equation for the spot size has been obtained by including the effects of relativistic self-focusing, ponderomotive self-channeling and preformed channel focusing. The propagation behaviors and their corresponding physical conditions are identified. The comparison of the propagation between q-Gaussian and Gaussian laser beams is done by theoretical and numerical analysis. It is shown that, in the same channel, the focusing power of q-Gaussian laser beam is lower than that of Gaussian laser beam, i.e., the q-Gaussian laser beam is easier to focus than Gaussian laser beam.

  3. Application of plasma focus installations for a study of the influence of deuterium cumulative flows on materials

    Indian Academy of Sciences (India)

    L I Ivanov; A I Dedyurin; I V Borovitskaya; O N Krokhin; V Ya Nikulin; S N Polukhin; A A Tikhomirov; A S Fedotov

    2003-12-01

    In this work, as an example of an application of the plasma focus (PF) device, we study the influence on alloys of vanadium of a cumulative flow producing in the PF device. The experiment was done in a 4-kJ PF device with various gas fillings and various anode shapes. It was found that the velocity of the axial cumulative flow depends on the type of gas and is about $5\\cdot 10^{7}$ cm/s for deuterium and $2\\cdot 10^{7}$ cm/s for argon fillings of plasma focus chamber; the shape of the flow is changed from a broad conical fly for deuterium to a quasi-one-directional stream for argon. The dynamics and structure of such flows are investigated by means of laser diagnostics and an image converter camera. The experiments show that cumulative flows produce various defects in tested samples. The appearance of a large number of cracks on the surface of vanadium under the impulse influence of deuterium plasma shows that pure vanadium cannot be used for the construction of thermonuclear fusion reactors. Such PF installations could also be used effectively for the study of other material and construction elements proposed for the use in thermonuclear machines.

  4. Laser Plasmas : Lie-optics, geometrical phase and nonlinear dynamics of self-focusing and soliton evolution in a plasma

    Indian Academy of Sciences (India)

    D Subbarao; R Uma; H Singh; Kamal Goyal; Sanjeev Goyal; Ravinder Kumar

    2000-11-01

    It is useful to state propagation laws for a self-focusing laser beam or a soliton in grouptheoretical form to be called Lie-optical form for being able to predict self-focusing dynamics conveniently and amongst other things, the geometrical phase. It is shown that the propagation of the gaussian laser beam is governed by a rotation group in a non-absorbing medium and by the Lorentz group in an absorbing medium if the additional symmetry of paraxial propagation is imposed on the laser beam. This latter symmetry, however, needs care in its implementation because the electromagnetic wave of the laser sees a different refractive index profile than the laboratory observer in this approximation. It is explained how to estimate this non-Taylor paraxial power series approximation. The group theoretical laws so-stated are used to predict the geometrical or Berry phase of the laser beam by a technique developed by one of us elsewhere. The group-theoretical Lie-optic (or ABCD) laws are also useful in predicting the laser behavior in a more complex optical arrangement like in a laser cavity etc. The nonlinear dynamical consequences of these laws for long distance (or time) predictions are also dealt with. Ergodic dynamics of an ensemble of laser beams on the torus during absorptionless self-focusing is discussed in this context. From the point of view of new physics concepts, we introduce a stroboscopic invariant torus and a stroboscopic generating function in classical mechanics that is useful for long-distance predictions of absorptionless self-focusing.

  5. Self-focusing and self-compression of a laser pulse in the presence of an external tapered magnetized density-ramp plasma

    Science.gov (United States)

    Saedjalil, N.; Jafari, S.

    2016-06-01

    In this paper, the effects of external tapered axial magnetic field and plasma density-ramp on the spatiotemporal evolution of the laser pulse in inhomogeneous plasma have been studied. The external magnetic field can modify the refractive index of plasma and consequently intensifies the nonlinear effects. By considering the relativistic nonlinearity effect, self-focusing and self-compression of the laser beam propagating through the magnetized plasma have been investigated, numerically. Numerical results indicate that self-focusing and self-compression are better enhanced in a tapered magnetic field than in a uniform one. Besides, in plasma density-ramp profile, self-focusing and self-compression of the laser beam improve in comparison with no ramp structure. In addition, with increasing both the slope of the density ramp and slope constant parameter of the tapered magnetic field, the laser focusing increases, properly, in short distances of the laser propagation through the plasma.

  6. Observed Multi-Decade DD and DT Z-Pinch Fusion Rate Scaling in 5 Dense Plasma Focus Fusion Machines

    Energy Technology Data Exchange (ETDEWEB)

    Hagen, E. C. [National Security Technologies, LLC; Lowe, D. R. [National Security Technologies, LLC; O' Brien, R. [University of Nevada, Las Vegas; Meehan, B. T. [National Security Technologies, LLC

    2013-06-18

    Dense Plasma Focus (DPF) machines are in use worldwide or a wide variety of applications; one of these is to produce intense, short bursts of fusion via r-Z pinch heating and compression of a working gas. We have designed and constructed a series of these, ranging from portable to a maximum energy storage capacity of 2 MJ. Fusion rates from 5 DPF pulsed fusion generators have been measured in a single laboratory using calibrated activation detectors. Measured rates range from ~ 1015 to more than 1019 fusions per second have been measured. Fusion rates from the intense short (20 – 50 ns) periods of production were inferred from measurement of neutron production using both calibrated activation detectors and scintillator-PMT neutron time of flight (NTOF) detectors. The NTOF detectors are arranged to measure neutrons versus time over flight paths of 30 Meters. Fusion rate scaling versus energy and current will be discussed. Data showing observed fusion cutoff at D-D fusion yield levels of approximately 1*1012, and corresponding tube currents of ~ 3 MA will be shown. Energy asymmetry of product neutrons will also be discussed. Data from the NTOF lines of sight have been used to measure energy asymmetries of the fusion neutrons. From this, center of mass energies for the D(d,n)3He reaction are inferred. A novel re-entrant chamber that allows extremely high single pulse neutron doses (> 109 neutrons/cm2 in 50 ns) to be supplied to samples will be described. Machine characteristics and detector types will be discussed.

  7. Low plasma aldosterone despite normal plasma renin activity in uncomplicated type 1 diabetes mellitus : effects of RAAS stimulation

    NARCIS (Netherlands)

    Luik, PT; Kerstens, MN; Hoogenberg, K; Navis, GJ; Dullaart, RPF

    2003-01-01

    Background Data on levels and responsiveness of PRA and aldosterone in type 1 diabetes mellitus are conflicting. Earlier studies were not standardized with respect to the type of diabetes mellitus, the presence of diabetic complications or sodium intake. Therefore, we studied plasma renin activity a

  8. Low plasma aldosterone despite normal plasma renin activity in uncomplicated type 1 diabetes mellitus : effects of RAAS stimulation

    NARCIS (Netherlands)

    Luik, PT; Kerstens, MN; Hoogenberg, K; Navis, GJ; Dullaart, RPF

    Background Data on levels and responsiveness of PRA and aldosterone in type 1 diabetes mellitus are conflicting. Earlier studies were not standardized with respect to the type of diabetes mellitus, the presence of diabetic complications or sodium intake. Therefore, we studied plasma renin activity

  9. Demonstration of relativistic electron beam focusing by a laser-plasma lens.

    Science.gov (United States)

    Thaury, C; Guillaume, E; Döpp, A; Lehe, R; Lifschitz, A; Ta Phuoc, K; Gautier, J; Goddet, J-P; Tafzi, A; Flacco, A; Tissandier, F; Sebban, S; Rousse, A; Malka, V

    2015-04-16

    Laser-plasma technology promises a drastic reduction of the size of high-energy electron accelerators. It could make free-electron lasers available to a broad scientific community and push further the limits of electron accelerators for high-energy physics. Furthermore, the unique femtosecond nature of the source makes it a promising tool for the study of ultrafast phenomena. However, applications are hindered by the lack of suitable lens to transport this kind of high-current electron beams mainly due to their divergence. Here we show that this issue can be solved by using a laser-plasma lens in which the field gradients are five order of magnitude larger than in conventional optics. We demonstrate a reduction of the divergence by nearly a factor of three, which should allow for an efficient coupling of the beam with a conventional beam transport line.

  10. Demonstration of electron beam focusing by a laser-plasma lens

    CERN Document Server

    Thaury, Cédric; Döpp, Andreas; Lehe, Remi; Lifschitz, Agustin; Phuoc, Kim Ta; Gautier, Julien; Goddet, Jean-Philippe; Tafzi, Amar; Flacco, Alessandro; Tissandier, Fabien; Sebban, Stéphane; Rousse, Antoine; Malka, Victor

    2014-01-01

    Laser-plasma technology promises a drastic reduction of the size of high energy electron accelerators. It could make free electron lasers available to a broad scientific community, and push further the limits of electron accelerators for high energy physics. Furthermore the unique femtosecond nature of the source makes it a promising tool for the study of ultra-fast phenomena. However, applications are hindered by the lack of suitable lens to transport this kind of high-current electron beams, mainly due to their divergence. Here we show that this issue can be solved by using a laser-plasma lens, in which the field gradients are five order of magnitude larger than in conventional optics. We demonstrate a reduction of the divergence by nearly a factor of three, which should allow for an efficient coupling of the beam with a conventional beam transport line.

  11. Prototype for Internet support of pregnant women and mothers with type 1 diabetes: focus group testing

    Directory of Open Access Journals (Sweden)

    Adolfsson A

    2012-08-01

    Full Text Available Annsofie Adolfsson,1,2 Malin Jansson1,21School of Life Sciences, University of Skovde, Skovde, Sweden; 2Department of Obstetrics and Gynaecology, Skaraborg Hospital, Skovde, SwedenBackground: The aim of this study was to pilot test a prototype website called MODIAB-web designed to support pregnant women and mothers with type 1 diabetes.Method: A focus group was undertaken and the results were analyzed using qualitative content analysis.Results: Eight subthemes were identified, comprising "blood glucose versus insulin," "application for smart phones," "the time aspect," "interface and technology," "forum," "direct link to the diabetes midwife," "ask the expert," and "lack of contact information." These subthemes were condensed into two main themes. The first theme was "easily understood interface, but in need of a more blood-glucose focused orientation" and the second theme was "forum for interaction with both equals and experts." Conclusion: The women in this study had positive impressions of several of the MODIAB-web functions, including a forum for pregnant mothers with type 1 diabetes and the possibility of being able to put their blood glucose levels into a diagram which could be sent directly to the diabetes midwife. Access to articles and information via the "fact" tab and the ability to ask questions of experts were also significantly helpful to women in the focus group. Pregnant women and mothers with type 1 diabetes can gain support from such a Web-based self-help system.Keywords: type 1 diabetes, web support, pregnancy, focus group interview

  12. Long-term insulin glargine therapy in type 2 diabetes mellitus: a focus on cardiovascular outcomes

    Directory of Open Access Journals (Sweden)

    Joseph JJ

    2015-01-01

    Full Text Available Joshua J Joseph, Thomas W Donner Division of Endocrinology, Diabetes and Metabolism, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA Abstract: Cardiovascular disease is the leading cause of mortality in type 2 diabetes mellitus. Hyperinsulinemia is associated with increased cardiovascular risk, but the effects of exogenous insulin on cardiovascular disease progression have been less well studied. Insulin has been shown to have both cardioprotective and atherosclerosis-promoting effects in laboratory animal studies. Long-term clinical trials using insulin to attain improved diabetes control in younger type 1 and type 2 diabetes patients have shown improved cardiovascular outcomes. Shorter trials of intensive diabetes control with high insulin use in higher risk patients with type 2 diabetes have shown either no cardiovascular benefit or increased all cause and cardiovascular mortality. Glargine insulin is a basal insulin analog widely used to treat patients with type 1 and type 2 diabetes. This review focuses on the effects of glargine on cardiovascular outcomes. Glargine lowers triglycerides, leads to a modest weight gain, causes less hypoglycemia when compared with intermediate-acting insulin, and has a neutral effect on blood pressure. The Outcome Reduction With Initial Glargine Intervention (ORIGIN trial, a 6.2 year dedicated cardiovascular outcomes trial of glargine demonstrated no increased cardiovascular risk. Keywords: glargine, insulin, type 2 diabetes, cardiovascular disease, cardiovascular outcomes

  13. Relativistic Spherical Wake Wave in Plasma. Relativistic focusing spherical mirror and Schwinger pair production

    Science.gov (United States)

    Bulanov, Stepan; Maksimchuk, Anatoly; Zhidkov, Alexei

    2009-11-01

    We report on the analytic and computer simulation study of a relativistic spherical wake wave. Such a wave in the breaking regime, traveling towards the center is able to reflect and focus the incoming radiation and up-shifting its frequency. The reflected and focused electromagnetic pulse can have such high intensity, that it is able to create e^+e^- pairs via Schwinger process.

  14. Demonstration of neutron production in a table-top pinch plasma focus device operating at only tens of joules

    Energy Technology Data Exchange (ETDEWEB)

    Soto, Leopoldo; Silva, Patricio; Moreno, Jose; Zambra, Marcelo; Pavez, Cristian [Comision Chilena de EnergIa Nuclear, Casilla 188-D, Santiago (Chile); Kies, Walter; Altamirano, Luis; Huerta, Luis [Center for Research and Applications in Plasma Physics and Pulsed Power, P4 (Chile); Mayer, Roberto E [Centro Atomico Bariloche and Instituto Balseiro, 8400 Bariloche (Argentina); Clausse, Alejandro [CNEA-CONICET and Universidad Nacional del Centro, 7000 Tandil (Argentina)], E-mail: lsoto@cchen.cl

    2008-10-21

    Neutron emission from a deuterium plasma pinch generated in a very small plasma focus (6 mm anode diameter) operating at only tens of joules is presented. A maximum current of 50 kA is achieved 140 ns after the beginning of the discharge, when the device is charged at 50 J (160 nF capacitor bank, 38 nH, 20-30 kV, 32-72 J). Although the stored energy is very low, the estimated energy density in the plasma and the energy per particle in the plasma are of the same order as in higher energy devices. The dependence of the neutron yield on the filling pressure of deuterium was obtained for discharges with 50 and 67 J stored in the capacitor bank. Neutrons were measured by means of a system based on a {sup 3}He proportional counter in current mode. The average neutron yield for 50 J discharges at 6 mbar was (1.2 {+-} 0.5) x 10{sup 4} neutrons per shot, and (3.6 {+-} 1.6) x 10{sup 4} for 67 J discharges at 9 mbar. The maximum energy of the neutrons was (2.7 {+-} 1.8) MeV. Possible applications related to substance detection and others are discussed.

  15. Bounds imposed on the sheath velocity of a dense plasma focus by conservation laws and ionization stability condition

    CERN Document Server

    Auluck, S K H

    2014-01-01

    Experimental data compiled over five decades of dense plasma focus research is consistent with the snowplow model of sheath propagation, based on the hypothetical balance between magnetic pressure driving the plasma into neutral gas ahead and wind pressure resisting its motion. The resulting sheath velocity, or the numerically proportional drive parameter, is known to be approximately constant for devices optimized for neutron production over 8 decades of capacitor bank energy. This paper shows that the validity of the snowplow hypothesis, with some correction, as well as the non-dependence of sheath velocity on device parameters, have their roots in local conservation laws for mass, momentum and energy coupled with the ionization stability condition. Both upper and lower bounds on sheath velocity are shown to be related to material constants of the working gas and independent of the device geometry and capacitor bank impedance.

  16. Design and initial results from a kilojoule level dense plasma focus with hollow anode and cylindrically symmetric gas puff

    Science.gov (United States)

    Ellsworth, J. L.; Falabella, S.; Tang, V.; Schmidt, A.; Guethlein, G.; Hawkins, S.; Rusnak, B.

    2014-01-01

    We have designed and built a Dense Plasma Focus (DPF) Z-pinch device using a kJ-level capacitor bank and a hollow anode, and fueled by a cylindrically symmetric gas puff. Using this device, we have measured peak deuteron beam energies of up to 400 keV at 0.8 kJ capacitor bank energy and pinch lengths of ˜6 mm, indicating accelerating fields greater than 50 MV/m. Neutron yields of on the order of 107 per shot were measured during deuterium operation. The cylindrical gas puff system permitted simultaneous operation of DPF with a radiofrequency quadrupole accelerator for beam-into-plasma experiments. This paper describes the machine design, the diagnostic systems, and our first results.

  17. Bounds imposed on the sheath velocity of a dense plasma focus by conservation laws and ionization stability condition

    Science.gov (United States)

    Auluck, S. K. H.

    2014-09-01

    Experimental data compiled over five decades of dense plasma focus research are consistent with the snowplow model of sheath propagation, based on the hypothetical balance between magnetic pressure driving the plasma into neutral gas ahead and "wind pressure" resisting its motion. The resulting sheath velocity, or the numerically proportional "drive parameter," is known to be approximately constant for devices optimized for neutron production over 8 decades of capacitor bank energy. This paper shows that the validity of the snowplow hypothesis, with some correction, as well as the non-dependence of sheath velocity on device parameters, have their roots in local conservation laws for mass, momentum, and energy coupled with the ionization stability condition. Both upper and lower bounds on sheath velocity are shown to be related to material constants of the working gas and independent of the device geometry and capacitor bank impedance.

  18. Dipeptidyl peptidase-4 inhibitors in type 2 diabetes therapy--focus on alogliptin.

    Science.gov (United States)

    Capuano, Annalisa; Sportiello, Liberata; Maiorino, Maria Ida; Rossi, Francesco; Giugliano, Dario; Esposito, Katherine

    2013-01-01

    Type 2 diabetes mellitus is a complex and progressive disease that is showing an apparently unstoppable increase worldwide. Although there is general agreement on the first-line use of metformin in most patients with type 2 diabetes, the ideal drug sequence after metformin failure is an area of increasing uncertainty. New treatment strategies target pancreatic islet dysfunction, in particular gut-derived incretin hormones. Inhibition of the enzyme dipeptidyl peptidase-4 (DPP-4) slows degradation of endogenous glucagon-like peptide-1 (GLP-1) and thereby enhances and prolongs the action of the endogenous incretin hormones. The five available DPP-4 inhibitors, also known as 'gliptins' (sitagliptin, vildagliptin, saxagliptin, linagliptin, alogliptin), are small molecules used orally with similar overall clinical efficacy and safety profiles in patients with type 2 diabetes. The main differences between the five gliptins on the market include: potency, target selectivity, oral bioavailability, long or short half-life, high or low binding to plasma proteins, metabolism, presence of active or inactive metabolites, excretion routes, dosage adjustment for renal and liver insufficiency, and potential drug-drug interactions. On average, treatment with gliptins is expected to produce a mean glycated hemoglobin (HbA1c) decrease of 0.5%-0.8%, with about 40% of diabetic subjects at target for the HbA1c goal pioglitazone, glibenclamide, voglibose, or insulin therapy significantly improves glycemic control compared with placebo in adult or elderly patients with inadequately controlled type 2 diabetes. In the EXAMINE trial, alogliptin is being compared with placebo on cardiovascular outcomes in approximately 5,400 patients with type 2 diabetes. In clinical studies, DPP-4 inhibitors were generally safe and well tolerated. However, there are limited data on their tolerability, due to their relatively recent marketing approval. Alogliptin will be used most when avoidance of

  19. Re-appraisal and extension of the Gratton-Vargas two-dimensional analytical snowplow model of plasma focus evolution in the context of contemporary research

    CERN Document Server

    Auluck, S K H

    2013-01-01

    Recent resurgence of interest in applications of dense plasma focus and doubts about the conventional view of dense plasma focus as a purely irrotational compressive flow have re-opened questions concerning device optimization. In this context, this paper re-appraises and extends the analytical snowplow model of plasma focus sheath evolution developed by F. Gratton and J.M. Vargas (GV) (Energy Storage, Compression and Switching, Ed. V. Nardi, H. Sahlin, and W. H. Bostick, Eds., vol. 2. New York: Plenum, 1983, p. 353) and shows its relevance to contemporary research. The GV model enables construction of a special orthogonal coordinate system in which the plasma flow problem can be simplified and a model of sheath structure can be formulated. The LPP plasma focus facility, which reports neutron yield better than global scaling law, is shown to be operating closer to an optimum operating point of the GV model as compared with PF-1000.

  20. Wear behavior of gas tunnel type plasma sprayed Zr-based metallic glass composite coatings

    Energy Technology Data Exchange (ETDEWEB)

    Yugeswaran, S., E-mail: yugeswaran@gmail.com [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Kobayashi, A., E-mail: kobayasi@jwri.osaka-u.ac.jp [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Suresh, K., E-mail: ksureshphy@gmail.com [Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong Special Administrative Region (China); Rao, K.P., E-mail: mekprao@cityu.edu.hk [Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong Special Administrative Region (China); Subramanian, B., E-mail: subramanianb3@gmail.com [CSIR - Central Electrochemical Research Institute, Karaikudi 630 006 (India)

    2012-09-01

    Highlights: Black-Right-Pointing-Pointer Zr-based metallic glass composite coatings are prepared by gas tunnel plasma torch. Black-Right-Pointing-Pointer Increasing plasma current increases crystallinity amount and hardness of coatings. Black-Right-Pointing-Pointer Coating produced at 300 A plasma current gives minimum sliding wear rate. Black-Right-Pointing-Pointer Coating produced at higher plasma current gives lower erosive wear rate. - Abstract: Gas tunnel type plasma spraying is a prospective method to produce metallic glass composite coatings with high quality due to its noteworthy feature of process controllability. In this study, Zr{sub 55}Cu{sub 30}Al{sub 10}Ni{sub 5} metallic glass composite coatings were produced by gas tunnel type plasma spraying torch under optimum spraying conditions with selected plasma currents. The formation mechanism, sliding, and erosive wear behaviors of the coatings with respect to plasma current was examined. The phase and thermal analyses as well as microstructure of the plasma sprayed coatings produced at different plasma currents were characterized using X-ray diffraction (XRD), differential scanning calorimetry (DSC), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDX) techniques. The sliding and erosive wear behaviors of the coatings were studied using a pin-on-disc and a specially designed erosive wear tester, respectively. The results showed that an increase in plasma current increased the crystalline content in the metallic glass composite coatings, which enhanced the hardness and wear resistance of the coatings.

  1. Dynamics of apokamp-type atmospheric pressure plasma jets

    Science.gov (United States)

    Sosnin, Eduard A.; Panarin, Victor A.; Skakun, Victor S.; Baksht, Evgeny Kh.; Tarasenko, Victor F.

    2017-02-01

    The paper describes a new discharge source of atmospheric pressure plasma jets (APPJs) in air with no gas supply through the discharge region. In this discharge mode, plasma jets develop from the bending point of a bright current channel between two electrodes and are therefore termed an apokamp (from Greek `off' and `bend'). The apokamp can represent single plasma jets of length up 6 cm or several jets, and the temperature of such jets can range from more than 1000 °C at their base to 100-250 °C at their tip. Apokamps are formed at maximum applied voltage of positive polarity, provided that the second electrode is capacitively decoupled with ground. According to high-speed photography with time resolution from several nanoseconds to several tens of nanoseconds, the apokamp consists of a set of plasma bullets moving with a velocity of 100-220 km/s, which excludes the convective mechanism of plasma decay. Estimates on a 100-ns scale show that the near-electrode zones and the zones from which apokamps develop are close in temperature.

  2. Potential plasma markers of type 1 and type 2 leprosy reactions: a preliminary report

    Directory of Open Access Journals (Sweden)

    Oliveira Maria

    2009-05-01

    Full Text Available Abstract Background The clinical management of leprosy Type 1 (T1R and Type 2 (T2R reactions pose challenges mainly because they can cause severe nerve injury and disability. No laboratory test or marker is available for the diagnosis or prognosis of leprosy reactions. This study simultaneously screened plasma factors to identify circulating biomarkers associated with leprosy T1R and T2R among patients recruited in Goiania, Central Brazil. Methods A nested case-control study evaluated T1R (n = 10 and TR2 (n = 10 compared to leprosy patients without reactions (n = 29, matched by sex and age-group (+/- 5 years and histopathological classification. Multiplex bead based technique provided profiles of 27 plasma factors including 16 pro inflammatory cytokines: tumor necrosis factor-α (TNF-α, Interferon-γ (IFN-γ, interleukin (IL- IL12p70, IL2, IL17, IL1 β, IL6, IL15, IL5, IL8, macrophage inflammatory protein (MIP-1 alpha (MIP1α, 1 beta (MIP1β, regulated upon activation normal T-cell expressed and secreted (RANTES, monocyte chemoattractrant protein 1 (MCP1, CC-chemokine 11 (CCL11/Eotaxin, CXC-chemokine 10 (CXCL10/IP10; 4 anti inflammatory interleukins: IL4, IL10, IL13, IL1Rα and 7 growth factors: IL7, IL9, granulocyte-colony stimulating factor (G-CSF, granulocyte macrophage-colony stimulating factor (GM-CSF, platelet-derived growth factor BB (PDGF BB, basic fibroblast growth factor (bFGF, vascular endothelial growth factor (VEGF. Results Elevations of plasma CXCL10 (P = 0.004 and IL6 (p = 0.013 were observed in T1R patients compared to controls without reaction. IL6 (p = 0.05, IL7 (p = 0.039, and PDGF-BB (p = 0.041 were elevated in T2R. RANTES and GMCSF were excluded due to values above and below detection limit respectively in all samples. Conclusion Potential biomarkers of T1R identified were CXCL10 and IL6 whereas IL7, PDGF-BB and IL6, may be laboratory markers of TR2. Additional studies on these biomarkers may help understand the

  3. Calibration of the RSS-131 high efficiency ionization chamber for radiation dose monitoring during plasma experiments conducted on plasma focus device

    Science.gov (United States)

    Szewczak, Kamil; Jednoróg, Sławomir

    2014-10-01

    Plasma research poses a radiation hazard. Due to the program of deuterium plasma research using the PF-1000 device, it is an intensive source of neutrons (up to 1011 n · pulse -1) with energy of 2,45 MeV and ionizing electromagnetic radiation with a broad energy spectrum. Both types of radiation are mostly emitted in ultra-short pulses (˜100 ns). The aim of this work was to test and calibrate the RSS-131 radiometer for its application in measurements of ultra-short electromagnetic radiation pulses with broad energy spectrum emitted during PF-1000 discharge. In addition, the results of raw measurements performed in the control room are presented.

  4. Use of DPP-4 inhibitors in type 2 diabetes: focus on sitagliptin

    Directory of Open Access Journals (Sweden)

    Bo Ahrén

    2010-03-01

    Full Text Available Bo AhrénDepartment of Clinical Sciences, Lund University, Lund, SwedenAbstract: Inhibition of dipeptidyl peptidase-4 (DPP-4 prevents the inactivation of glucagonlike peptide-1 (GLP-1. This increases circulating levels of active GLP-1, stimulates insulin secretion and inhibits glucagon secretion, which results in lowering of glucose levels and improvement of the glycemic control in patients with type 2 diabetes. This review summarizes experiences with DPP-4 inhibition in the treatment of type 2 diabetes, with a focus on sitagliptin. Sitagliptin has in several clinical studies been shown to improve metabolic control in type 2 diabetes, both when used as monotherapy and when used in combination with metformin, sulfonylurea, thiazolidinediones or insulin. The reduction in HbA1c is ≈0.6% to 1.0% from baseline levels of 7.5% to 8.7% over 6 to 12 months therapy. Sitagliptin has a favorable safety profile, is highly tolerable, and there is a minimal risk of hypoglycemia. Furthermore, sitagliptin is body weight neutral or induces a slight body weight reduction. Sitagliptin may be used in the early stages of type 2 diabetes in combination with metformin or other treatments in subjects with inadequate glycemic control on these treatments alone. Sitagliptin may also be used in monotherapy and, finally, sitagliptin may be used in combination with insulin in more advanced stages of the disease.Keywords: glucagon-like peptide-1, dipeptidyl peptidase-4, type 2 diabetes, sitagliptin, treatment

  5. Numerical simulation to study the transient self focusing of laser beam in plasma

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, R. P.; Hussain, Saba, E-mail: sabahussain44@yahoo.com; Gaur, Nidhi [Centre for Energy Studies, Indian Institute of Technology Delhi, New Delhi 110016 (India)

    2015-02-15

    In this paper, we present the numerical simulation for the coupled system of equations governing the dynamics of laser and Ion Acoustic Wave (IAW) in a collisionless plasma, when the coupling between the waves is through ponderomotive non-linearity. The nonlinear evolution of the laser beam is studied when the pump laser is perturbed by a periodic perturbation. By changing the perturbation wave number, we have studied its effect on the nonlinear evolution pattern of laser beam. In order to have a physical insight into the nonlinear dynamics of laser beam evolution in time and space, we have studied the laser and IAW spectra containing spatial harmonics. The magnitude of these harmonics changes with time and leads to time dependent localization of laser beam in spatial domain. The nonlinear dynamics of this localization is investigated in detail by using simulation and a semi-analytical model.

  6. Investigations on the transition between column and micropinch mode of plasma focus operation

    Science.gov (United States)

    Lebert, R.; Engel, A.; Neff, W.

    1995-12-01

    X-ray emission from pinch plasma devices with pinch currents ranging from 200 to 400 kA operated with pure high-Z gases are investigated with temporal spatial and spectral resolution. If operated using elements Zneon) K-shell emission is observed from column-like volumes several 100 μm in diameter and several mm in length (bulk or column mode). For Z≳18 (e.g., krypton or xenon) emission with hν≳1 keV is only observed from micropinches. For argon (Z=18) both modes of operation can be observed. The occurrence of a specific mode depends on the initial gas pressure. In this paper the transition regime between column and micropinches is investigated with particular regard to argon. A criterion is proposed to decide whether column mode or micropinch mode is expected.

  7. Experimental study of soft X-ray intensity with different anode tips in Amirkabir plasma focus device

    Indian Academy of Sciences (India)

    HABIBI MORTEZA; MAHTAB MAHSA

    2016-07-01

    To study the effect of different anode tip geometries on the intensity of soft X-rays emitted from a 4 kJ plasma focus device (PFD), we considered five different anode tips which were cylindrical-flat, cylindricalhollow, spherical-convex, cone-flat and cone-hollow tips. BPX-65 PIN diodes covered by four different filters are used to register the intensity of soft X-rays. The use of cone-flat anode tip has augmented the emitted X-ray three times compared to the conventional cylindrical-flat anode.

  8. Dense plasma focus PACO as a hard X-ray emitter: a study on the radiation source

    OpenAIRE

    Supán, L.; Guichón, S.; Milanese, Maria Magdalena; Niedbalski, Jorge Julio; Moroso, Roberto Luis; Acuña, H.; Malamud, Florencia

    2016-01-01

    The radiation in the X-ray range detected outside the vacuum chamber of the dense plasma focus (DPF) PACO, are produced on the anode zone. The zone of emission is studied in a shot-to-shot analysis, using pure deuterium as filling gas. We present a diagnostic method to determine the place and size of the hard X-ray source by image analysis of high density radiography plates. Fil: Supán, L.. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Insti...

  9. Electron Beam Focusing and Spreading due to interactions With Copropagating Plasma Waves and Lasers: Explanation of Simulation Results

    Science.gov (United States)

    Bowman, A.; Williams, R. L.

    2016-10-01

    Numerical simulation results suggest that a low energy electron beam, injected perpendicularly across co-propagating plasma waves and laser beams, can be compressed to a line focus under certain conditions, but under different conditions can be spread out into two main lobes on which bunching patterns are impressed. We report several explanations for these observations, and also discuss the similarity of these results to other research results previously reported in the literature. The prospects for testing these results in a laboratory will be discussed, as well as the use of these phenomena as diagnostics. Supported by the Department of Energy.

  10. Postprandial hyperglycemia and endothelial function in type 2 diabetes: focus on mitiglinide

    Directory of Open Access Journals (Sweden)

    Kitasato Lisa

    2012-06-01

    Full Text Available Abstract The risk of cardiovascular complication in a diabetes patient is similar to that in a nondiabetic patient with a history of myocardial infarction. Although intensive control of glycemia achieved by conventional antidiabetic agents decreases microvascular complications such as retinopathy and nephropathy, no marked effect has been reported on macrovascular complications or all-cause mortality. Evidence from VADT, ACCORD, and ADVANCE would suggest that glycemic control has little effect on macrovascular outcomes. Moreover, in the case of ACCORD, intensive glycemic control may be associated with an increased risk of mortality. There is sufficient evidence that suggests that postprandial hyperglycemia may be an independent risk factor for cardiovascular disease in diabetes patients. However, there are no prospective clinical trials supporting the recommendation that lowering postprandial blood glucose leads to lower risk of cardiovascular outcomes. Mitiglinide is a short-acting insulinotropic agent used in type 2 diabetes treatment. It has a rapid stimulatory effect on insulin secretion and reduces postprandial plasma glucose level in patients with type 2 diabetes. Because of its short action time, it is unlikely to exert adverse effects related to hypoglycemia early in the morning and between meals. Mitiglinide reduces excess oxidative stress and inflammation, plays a cardioprotective role, and improves postprandial metabolic disorders. Moreover, mitiglinide add-on therapy with pioglitazone favorably affects the vascular endothelial function in type 2 diabetes patients. These data suggest that mitiglinide plays a potentially beneficial role in the improvement of postprandial hyperglycemia in type 2 diabetes patients and can be used to prevent cardiovascular diseases. Although the results of long-term, randomized, placebo-controlled trials for determining the cardiovascular effects of mitiglinide on clinical outcomes are awaited, this

  11. Postprandial hyperglycemia and endothelial function in type 2 diabetes: focus on mitiglinide.

    Science.gov (United States)

    Kitasato, Lisa; Tojo, Taiki; Hatakeyama, Yuko; Kameda, Ryo; Hashikata, Takehiro; Yamaoka-Tojo, Minako

    2012-06-29

    The risk of cardiovascular complication in a diabetes patient is similar to that in a nondiabetic patient with a history of myocardial infarction. Although intensive control of glycemia achieved by conventional antidiabetic agents decreases microvascular complications such as retinopathy and nephropathy, no marked effect has been reported on macrovascular complications or all-cause mortality. Evidence from VADT, ACCORD, and ADVANCE would suggest that glycemic control has little effect on macrovascular outcomes. Moreover, in the case of ACCORD, intensive glycemic control may be associated with an increased risk of mortality. There is sufficient evidence that suggests that postprandial hyperglycemia may be an independent risk factor for cardiovascular disease in diabetes patients. However, there are no prospective clinical trials supporting the recommendation that lowering postprandial blood glucose leads to lower risk of cardiovascular outcomes. Mitiglinide is a short-acting insulinotropic agent used in type 2 diabetes treatment. It has a rapid stimulatory effect on insulin secretion and reduces postprandial plasma glucose level in patients with type 2 diabetes. Because of its short action time, it is unlikely to exert adverse effects related to hypoglycemia early in the morning and between meals. Mitiglinide reduces excess oxidative stress and inflammation, plays a cardioprotective role, and improves postprandial metabolic disorders. Moreover, mitiglinide add-on therapy with pioglitazone favorably affects the vascular endothelial function in type 2 diabetes patients. These data suggest that mitiglinide plays a potentially beneficial role in the improvement of postprandial hyperglycemia in type 2 diabetes patients and can be used to prevent cardiovascular diseases. Although the results of long-term, randomized, placebo-controlled trials for determining the cardiovascular effects of mitiglinide on clinical outcomes are awaited, this review is aimed at summarizing

  12. The effects of pre-ionization using a shunt resistor on reproducibility of the x-ray emission in a dense plasma focus device

    Science.gov (United States)

    Piriaei, D.; Yousefi, H. R.; Mahabadi, T. D.; SalarElahi, A.; Ghoranneviss, M.

    2017-08-01

    In this research, the effects of pre-ionization using a shunt resistor on reproducibility of x-ray emission in a Mather type plasma focus device have been studied. This technique increased the intensities of the emitted x-rays from argon as the filling gas of the device and made the x-ray yields with similar intensities reproducible. A Mirnov coil was also used to record the variations of the plasma's magnetic field, and the wavelet spectrums of these recorded signals showed the reduced instabilities due to the application of the pre-ionization technique. Moreover, it was demonstrated that this technique was capable of reducing the number of initial runaway electrons that could increase the impurities and instabilities inside the plasma. In addition to the above-mentioned features, this technique could improve the uniform formation of the current sheath during the breakdown phase that might later lead to a high quality pinch and high intensity emitted x-rays.

  13. Effects of relativistic and channel focusing on q-Gaussian laser beam propagating in a preformed parabolic plasma channel

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Li; Hong, Xue-Ren, E-mail: hxr_nwnu@163.com; Sun, Jian-An, E-mail: sunja@nwnu.edu.cn; Tang, Rong-An; Yang, Yang; Zhou, Wei-Jun; Tian, Jian-Min; Duan, Wen-Shan

    2017-07-12

    The propagation of q-Gaussian laser beam in a preformed plasma channel is investigated by means of the variational method. A differential equation for the spot size has been obtained by including the effects of relativistic self-focusing, ponderomotive self-channeling and preformed channel focusing. The propagation behaviors and their corresponding physical conditions are identified. The comparison of the propagation between q-Gaussian and Gaussian laser beams is done by theoretical and numerical analysis. It is shown that, in the same channel, the focusing power of q-Gaussian laser beam is lower than that of Gaussian laser beam, i.e., the q-Gaussian laser beam is easier to focus than Gaussian laser beam. - Highlights: • Some behaviors for Gaussian laser are also found for q-Gaussian one. • The parameter regions corresponding to different laser behaviors are given. • Influence of q on the laser propagation behavior is obvious. • The q-Gaussian laser beam is easier to focus than the Gaussian one.

  14. Interaction of a self-focused laser beam with a DT fusion target in a plasma-loaded cone-guided ICF scheme

    Science.gov (United States)

    Saedjalil, N.; Mehrangiz, M.; Jafari, S.; Ghasemizad, A.

    2016-06-01

    In this paper, the interaction of a self-focused laser beam with a DT fusion target in a plasma-loaded cone-guided ICF scheme has been presented. We propose here to merge a plasma-loaded cone with the precompressed DT target in order to strongly focus the incident laser beam on the core to improve the fusion gain. The WKB approximation is used to derive a differential equation that governs the evolution of beamwidth of the incident laser beam with the distance of propagation in the plasma medium. The effects of initial plasma and laser parameters, such as initial plasma electron temperature, initial radius of the laser beam, initial laser beam intensity and plasma density, on self-focusing and defocusing of the Gaussian laser beam have been studied. Numerical results indicate that with increasing the plasma frequency (or plasma density) in the cone, the laser beam will be self-focused noticeably, while for a thinner laser beam (with small radius), it will diverge as propagate in the cone. By evaluating the energy deposition of the relativistic electron ignitors in the fuel, the importance of electron transportation in the cone-attached shell was demonstrated. Moreover, by lessening the least energy needed for ignition, the electrons coupling with the pellet enhances. Therefore, it increases the fusion efficiency. In this scheme, with employing a plasma-loaded cone, the fusion process improves without needing an ultrahigh-intensity laser beam in a conventional ICF.

  15. Performance of Focused Ion Beam Trimmed Yoke-Type Magnetoresistive Heads for Magnetic Microscopy

    OpenAIRE

    Phillips, Gavin N.; Eisenberg, Martin; Draaisma, Eddie A.; Abelmann, Leon; Lodder, J. Cock

    2002-01-01

    Thin-film yoke-type magnetoresistive (MR) tape heads with eight channels have been used for scanning magnetoresistance microscopy. The NiFe read flux guides of the channels have been trimmed down from 12 ¿m to widths varying between 5 ¿m and 100 nm by focused ion-beam milling with Ga+ ions. The tape-bearing surface of the milled regions has been reconstructed in situ by the local deposition of Pt. Tracks with a minimum bit length of 1 ¿m have been written on Co-Ni-O metal evaporated tape and ...

  16. Modulation of C1-Inhibitor and Plasma Kallikrein Activities by Type IV Collagen

    Directory of Open Access Journals (Sweden)

    Sriram Ravindran

    2012-01-01

    Full Text Available The contact system of coagulation can be activated when in contact with biomaterials. As collagen is being tested in novel biomaterials in this study, we have investigated how type IV collagen affects plasma kallikrein and C1-inhibitor. Firstly, we showed C1-inhibitor binds to type IV collagen with a Kd of 0.86 μM. The effects of type IV collagen on plasma kallikrein, factor XIIa, and β-factor XIIa activity and on C1-inhibitor function were determined. Factor XIIa rapidly lost activity in the presence of type IV collagen, whereas plasma kallikrein and β-factor XIIa were more stable. The rate of inhibition of plasma kallikrein by C1-inhibitor was decreased by type IV collagen in a dose-dependent manner. These studies could be relevant to the properties of biomaterials, which contain collagen, and should be considered in the testing for biocompatibility.

  17. Integrated lens auto-focus system driven by a nut-type ultrosonic motor (USM)

    Institute of Scientific and Technical Information of China (English)

    ZHOU TieYing; CHEN Yu; LU CunYue; FU DeYong; HU XiaoPing; LI Yi; TIANBin

    2009-01-01

    This paper introduces an integrated optical auto-focus system driven by a nut-type ultrasonic motor (USM). The system comprises an optical lens as a rotor (M6 or M7), a polyhedral tube of copper as a stator; an image sensor, and a driver IC of the motor. The sizes of the AF (auto-focus) module are 8.5 mm×8.5 mm×5.9 mm. The piezoelectric elements are bonded on the external surface of the stator. The rotor has external screw thread that engages with the inner screw thread of the stator. When the pie-zoelectric elements are excited by the driver IC, a bend traveling wave in plane is generated on the stator along the circle direction, that drives the lens rotor to rotate and then to move axially. The driver IC is controlled by an image feedback of an image sensor centered on the axis of the casing, then the optical focusing is realized. The power consumption is zero at rest and is less than 0.25 W in motion; focusing precision 3 r/s(180 r/min); response <10 ms; high reliability: resistant to shock and fall off; directly driven by the driver IC without transmission mechanism; the friction force is namely the driving force and noiseless. The integrated optical auto-focus system is very useful, espe-cially for cellular phones. The image resolution of 3-5 MP has been obtained in the module prototypes of the cellular phone.

  18. Integrated lens auto-focus system driven by a nut-type ultrosonic motor (USM)

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    This paper introduces an integrated optical auto-focus system driven by a nut-type ultrasonic motor (USM). The system comprises an optical lens as a rotor (M6 or M7), a polyhedral tube of copper as a stator; an image sensor, and a driver IC of the motor. The sizes of the AF (auto-focus) module are 8.5 mm×8.5 mm×5.9 mm. The piezoelectric elements are bonded on the external surface of the stator. The rotor has external screw thread that engages with the inner screw thread of the stator. When the piezoelectric elements are excited by the driver IC, a bend traveling wave in plane is generated on the stator along the circle direction, that drives the lens rotor to rotate and then to move axially. The driver IC is controlled by an image feedback of an image sensor centered on the axis of the casing, then the optical focusing is realized. The power consumption is zero at rest and is less than 0.25 W in motion; focusing precision <10 μm; speed >3 r/s(180 r/min); response <10 ms; high reliability: resistant to shock and fall off; directly driven by the driver IC without transmission mechanism; the friction force is namely the driving force and noiseless. The integrated optical auto-focus system is very useful, especially for cellular phones. The image resolution of 3―5 MP has been obtained in the module prototypes of the cellular phone.

  19. Skin Depth vs. Relativistics Self-focusing at ps Laser-Plasma Interaction

    Science.gov (United States)

    Hora, Heinrich; Peng, Hansheng; Zhang, Weiyan; Osman, Frederick

    2002-03-01

    Highly charged MeV ions from target irradiated by laser longer than 0.1 ns, can be explained by relativistic self-focusing and subsequent acceleration by the nonlinear (ponderomotive) force [1]. In strong contrast to this, same laser intensities of ps pulses produced hundred times less energetic ions if the contrast ratio for suppression of prepulses was sufficiently high [1]. It was remarkable that the number of ions was constant and the ion energy linear on the laser intensity. We developed a model to explain the measurements as interactions within the skin layer of the target in contrast to relativistic self-focusing. However, if there is an appropriate prepulse applied, the MeV ions appear as before with the ns pulses which can be explained by the then possible relativistic self focusing. Consequences for the fast ignitor laser fusion scheme are elaborated. [1] J. Badziak, et al. Laser and Particle Beams 17, 323 (1999); E. Woryna, J. Wolowski, B. Kralikowa, J. Kraska, L. Laska, M. Pfeifer, K. Rohlena, J. Skala, V. Perina, R. Höpfl, & H. Hora, Rev. Scient. Instrum. 71, 949 (2000).

  20. Elevated plasma levels of chemerin in newly diagnosed type 2 diabetes mellitus with hypertension.

    Science.gov (United States)

    Yang, Mengliu; Yang, Gangyi; Dong, Jing; Liu, Ying; Zong, Haihong; Liu, Hua; Boden, Guenther; Li, Ling

    2010-10-01

    Chemerin is a recently discovered metabolic regulator hormone. The pathophysiologic role of this hormone in humans remains unknown. In this study, we have compared plasma chemerin levels in patients with type 2 diabetes mellitus with or without hypertension and in control subjects. We also assessed the association of plasma chemerin with body composition and metabolic parameters in these subjects. Plasma chemerin levels were found to be markedly increased in patients with type 2 diabetes mellitus with hypertension as compared with patients with type 2 diabetes mellitus and normal controls (P < 0.01). Multiple regression analysis showed that waist circumference, diastolic blood pressure, 2-hour plasma insulin after glucose overload, and HbA1c were independently related factors influencing plasma chemerin levels. The present work indicates the potential link of chemerin with the pathogenesis of insulin resistance, obesity, and metabolic syndrome.

  1. Argon ion beam interaction on polyethylene terephthalate surface by a 4 kJ plasma focus device

    Indian Academy of Sciences (India)

    Habibi Morteza; Alavi M H S

    2016-03-01

    Polyethylene terephthalate (PET) has a wide variety of applications ranging from making regular bottles to biosensors. However, for many of these applications, surface treatment is needed to improve its surface characteristics such as adhesion to other materials. In this study, we focussed on treating PET foils by dense Ar pulsed plasma produced by a 4.5 kJ Mather-type plasmafocus device (20 kV, 40 $\\mu$f, 115 nH) to examine its ability to make the PET surface hydrophilic. The most common method to examine this characteristic is measuring the water contact angle on a polymer surface. The results show that while the energy and density of plasma in our device are higher compared to other devices, as the exposure time is very low, the device can enhance thewettability of PET film surfaces.

  2. Study on the application of plasma technology to advanced global environmental harmony type technology; Kankyo chowagata gijutsu no kodoka eno plasma no oyo ni kansuru chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Plasma application technology is systematically investigated. Fundamental feature of plasma, method of plasma generation, special features of plasma, and its application area are arranged. The present application area of plasma chemical reaction in industry has been arranged for each utilization and process according to the patents research and scientific journals. For the global environmental harmony type technology, functions required for the membrane separators are investigated by assuming the recovery of environmental load substances, and possible manufacturing process of the membrane by using plasma technology is also investigated. For the improvement of catalysis by the plasma process, the requirement for the catalyst, a fine particle effect for catalyst, production of catalyst, plasma technology applicable to the improvement of catalyst, thermal plasma, and low-temperature plasma are described. For the application of plasma to enhance the catalysis reaction, synthesis of ammonia and methanol are described. 177 refs., 67 figs., 18 tabs.

  3. Dipeptidyl peptidase-4 inhibitors in type 2 diabetes therapy – focus on alogliptin

    Directory of Open Access Journals (Sweden)

    Capuano A

    2013-09-01

    Full Text Available Annalisa Capuano,1 Liberata Sportiello,1 Maria Ida Maiorino,2 Francesco Rossi,1 Dario Giugliano,2 Katherine Esposito3 1Department of Experimental Medicine, 2Department of Medical, Surgical, Neurological, Metabolic Sciences, and Geriatrics, 3Department of Clinical and Experimental Medicine and Surgery, Second University of Naples, Naples, Italy Abstract: Type 2 diabetes mellitus is a complex and progressive disease that is showing an apparently unstoppable increase worldwide. Although there is general agreement on the first-line use of metformin in most patients with type 2 diabetes, the ideal drug sequence after metformin failure is an area of increasing uncertainty. New treatment strategies target pancreatic islet dysfunction, in particular gut-derived incretin hormones. Inhibition of the enzyme dipeptidyl peptidase-4 (DPP-4 slows degradation of endogenous glucagon-like peptide-1 (GLP-1 and thereby enhances and prolongs the action of the endogenous incretin hormones. The five available DPP-4 inhibitors, also known as 'gliptins' (sitagliptin, vildagliptin, saxagliptin, linagliptin, alogliptin, are small molecules used orally with similar overall clinical efficacy and safety profiles in patients with type 2 diabetes. The main differences between the five gliptins on the market include: potency, target selectivity, oral bioavailability, long or short half-life, high or low binding to plasma proteins, metabolism, presence of active or inactive metabolites, excretion routes, dosage adjustment for renal and liver insufficiency, and potential drug–drug interactions. On average, treatment with gliptins is expected to produce a mean glycated hemoglobin (HbA1c decrease of 0.5%–0.8%, with about 40% of diabetic subjects at target for the HbA1c goal <7%. There are very few studies comparing DPP-4 inhibitors. Alogliptin as monotherapy or added to metformin, pioglitazone, glibenclamide, voglibose, or insulin therapy significantly improves glycemic control

  4. Theoretical and experimental study of inertial gases admixtures influence on the hard x-ray emission of plasma focus

    Science.gov (United States)

    Dulatov, A. K.; Lemeshko, B. D.; Mikhailov, Yu V.; Prokuratov, I. A.; Selifanov, A. N.

    2015-11-01

    This paper studies the influence of inertial gases admixtures (Ar, Kr, Xe) to deuterium in plasma focus (PF) chambers. Experiments were realized in PF chambers with discharge currents of 350, 650 and 1000 kA. The measurements of the hard x-ray (HXR) emission were carried out by the scintillation detector SSDI38 with time resolution of 2.5 ns. Experiments show the existence of optimum amount of inertial gases, which corresponds with the atomic number of added gas. At the optimum amount of inertial gas and deuterium in PF chamber, the HXR yield rises up to 10 times in comparison with HXR yield only for deuterium filling. This work shows the dependence of HXR emission on PF device stored energy. The mechanism of inertial gases admixtures influence that leads to rise of HXR yield has been discussed. The mechanism concerns with different behavior of deuterium ions and ions of inertial gases during the pinch decay phase when the discharge current compression force has reduced. Inertial gas ions locate near the axis of the pinch and deuterium ions go to the near plasma area. Local positive charge in plasma forms on this axis because of multiply charged ions of inertial gases. Then electrons gather to the axis area and electron density increases. This electrons form high current electron beam under the influence of the induced electromotive force during the pinch decay phase. HXR emission is generated after the electron beam interaction with the anode target in PF chamber.

  5. Axial and radial preliminary results of the neutron radiation from miniature plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, J.; Silva, P.; Soto, L. [Comision Chilena de Energia Nuclear, Santiago (Chile)

    2004-07-01

    As first step of a program to design a repetitive pulsed neutron generator for applications, two miniature plasma foci have been designed and constructed at the Chilean commission of nuclear energy. The devices operate at an energy level of the order of tens of joules (PF-50 J, 160 nF capacitor bank, 20-35 kV, 32-100 J, {approx} 150 ns time to peak current) and hundred of joules (PF-400 J, 880 nF, 20-35 kV, 176-539 J, {approx} 300 ns time to peak current). Neutron emission has been obtained in both devices operating in deuterium. A specific technique was necessary to develop in order to detect neutron pulsed of 10{sup 4} neutrons per shot. The maximum total neutron yield measured was of the order of 10{sup 6} and 10{sup 4} neutrons per shot in the PF-400 J and PF-50 J respectively. Axial and radial measurements of the neutron emission are presented and the anisotropy is evaluated in this work. The neutrons are measured by pairs of silver activation counters, {sup 3}He detectors and scintillator-photomultiplier detectors. (authors)

  6. The effect of anode shape on neon soft x-ray emissions and current sheath configuration in plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadi, M A; Sobhanian, S [Faculty of Physics, University of Tabriz, Tabriz (Iran, Islamic Republic of); Wong, C S [Plasma Research Laboratory, Physics Department, University of Malaya, Kuala Lumpur (Malaysia); Lee, S; Lee, P; Rawat, R S, E-mail: rajdeep.rawat@nie.edu.s [Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University (Singapore)

    2009-02-21

    The effect of three different anode shapes, flat, tapered and hemispherical, on the x-ray emission characteristics of a neon filled UNU-ICTP plasma focus device is investigated. The current sheath dynamics, in the radial collapse phase, has been simultaneously interrogated using the laser shadowgraphy method to understand the variation in x-ray emission characteristics for anodes of different shapes used in the experiments. The maximum neon soft x-ray (SXR) yield for the flat anode is about 7.5 {+-} 0.4 J at 4 mbar, whereas for hemispherical and tapered anodes the neon SXR is almost halved with the optimum pressure shifting to a lower value of 3 mbar. The laser shadowgraphic images confirm that the reduction in the overall neon SXR yield is due to the reduced focused plasma column length for these anodes. The relative HXR yield was the highest for the hemispherical anode followed by the tapered and the flat anodes in that order. The shadowgraphic images and the voltage probe signals confirmed that for the hemispherical anode the multiple-pinch phenomenon was most commonly observed, which could be responsible for multiple HXR bursts for this anode with maximum HXR yields.

  7. ESTIMATING RATIO OF PEAK TO UNIFORM VALUES OF VARIOUS PROFILES OF RELEVANCE TO PLASMA FOCUS PINCH COLUMNS

    Directory of Open Access Journals (Sweden)

    CHONG PERK LIN

    2013-02-01

    Full Text Available In the Lee Model code for radiative plasma focus computation, both the density profile and the temperature profile (versus anode radius of the pinch column are approximated by step functions with uniform values across the column radius. This means that the computed density and temperatures will be lower than the physical situation where the density and temperature profiles will certainly have peak values higher than the uniform (with radius values of the step function. It has been shown that the density profile is side-peaked (somewhat shell-shaped or like the shape of a volcanic crater with the assumption of no reflected shock wave; whereas the temperature profile is centre-peaked somewhat like a Gaussian shape. The aim of this paper is to investigate the use of higher degree mathematical function, where the crater-shaped profile can be well represented, to pproximate the plasma focus density profile. Two different approximated functions will be discussed: namely Gaussian distribution function and Bézier function. From these profiles we obtain the likely ratio of the profiled peak temperature to the step function uniform temperature and the peak density to the step function uniform density. In this manner we are able to suggest correction factors to the temperature and density computed by the Lee Model code.

  8. Electron self-injection during interaction of tightly focused few-cycle laser pulses with underdense plasma

    Science.gov (United States)

    Zhidkov, Alexei; Fujii, Takashi; Nemoto, Koshichi

    2008-09-01

    We study the interaction of short laser pulses tightly focused in a tiny volume proportional to the cube of the pulse wavelength (λ3) with underdense plasma by means of real-geometry particle-in-cell simulations. Underdense plasma irradiated by relatively low-energy λ3 (and λ2 ) laser pulses is shown to be an efficient source of multi-MeV electrons, ˜50nC/J , and coherent hard x rays, despite a strong pulse diffraction. Transverse wave breaking in the vicinity of the laser focus is found to give rise to an immense electron charge loading to the acceleration phase of a laser wake field. A strong blowout regime provoked by the injected electrons resulting in the distribution of accelerated electrons is found for λ3 pulses (further electron acceleration driving by λ2 pulses runs in the usual way). With an increase of pulse energy, wiggling and electron-hose instabilities in the λ3 pulse wake are recognized in the blowout regime. For higher-energy λ3 pulses, the injected beams are well modulated and may serve as a good source of coherent x rays.

  9. Multicusp type machine for electron cyclotron resonance plasma with reduced dimensions

    Science.gov (United States)

    Amemiya, H.; Maeda, M.

    1996-03-01

    Plasmas are created in a cusp type magnetic trap using electron cyclotron resonance heating. The magnetic field is generated with permanent magnets forming a 12-pole, whereby the polarity at the ends of the rods has been reversed in order to obtain end plugs and to improve the plasma confinement. In this way, the plasma volume could be reduced such that the cross section was close to or smaller than the cutoff width of a circular waveguide. This increases the microwave power absorbed and gives a high plasma density even above the cutoff value.

  10. Multicusp type machine for electron cyclotron resonance plasma with reduced dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Amemiya, H.; Maeda, M. [The Institute of Physical and Chemical Research (RIKEN), Hirosawa 2-1, Wako-shi, Saitama-Pref., 351-01 (Japan)

    1996-03-01

    Plasmas are created in a cusp type magnetic trap using electron cyclotron resonance heating. The magnetic field is generated with permanent magnets forming a 12-pole, whereby the polarity at the ends of the rods has been reversed in order to obtain end plugs and to improve the plasma confinement. In this way, the plasma volume could be reduced such that the cross section was close to or smaller than the cutoff width of a circular waveguide. This increases the microwave power absorbed and gives a high plasma density even above the cutoff value. {copyright} {ital 1996 American Institute of Physics.}

  11. Property control of expanding thermal plasma deposited textured zinc oxide with focus on thin film solar cell applications

    Energy Technology Data Exchange (ETDEWEB)

    Groenen, R. [Eindhoven University of Technology, Department of Applied Physics, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Loeffler, J. [Utrecht University, Debye Institute, SID-Physics of Devices, P.O. Box 80000, 3508 TA Utrecht (Netherlands); Linden, J.L. [TNO TPD, Division Models and Processes, P.O. Box 595, 5600 AN Eindhoven (Netherlands); Schropp, R.E.I. [Utrecht University, Debye Institute, SID-Physics of Devices, P.O. Box 80000, 3508 TA Utrecht (Netherlands); Sanden, M.C.M. van de [Eindhoven University of Technology, Department of Applied Physics, P.O. Box 513, 5600 MB Eindhoven (Netherlands)]. E-mail: m.c.m.v.d.sanden@tue.nl

    2005-12-01

    Property control of expanding thermal plasma deposited textured zinc oxide is demonstrated considering intrinsic, i.e. bulk, and extrinsic transparent conducting oxide quality relevant for application in thin film amorphous silicon pin solar cells. Particularly the interdependence of electrical conductivity, film composition and film morphology, i.e. structure, feature shape and roughness of the surface, is addressed. Control of film composition is mainly governed by plasma production and gas phase chemistry inherently inducing a significant contribution to film morphology, whereas control of film morphology solely is governed by near-substrate conditions. Especially the ratio of zinc to oxygen and the reactor chamber pressure appear to be determinative in obtaining zinc oxide exhibiting the appropriate intrinsic and extrinsic quality, i.e. a high electrical conductivity, a high transmittance, a textured rough surface morphology and a strong hydrogen plasma resistance. The solar cell performance of appropriate undoped and aluminium doped textured zinc oxide inherently obtained during deposition is comparable with respect to Asahi U-type fluorine-doped tin oxide.

  12. Clinical Implication of Plasma Hydrogen Sulfide Levels in Japanese Patients with Type 2 Diabetes

    Science.gov (United States)

    Suzuki, Kunihiro; Sagara, Masaaki; Aoki, Chie; Tanaka, Seiichi; Aso, Yoshimasa

    2017-01-01

    Objective The goal of the present study was to investigate the plasma hydrogen sulfide (H2S) levels in patients with type 2 diabetes, as the plasma H2S levels in Japanese patients with type 2 diabetes remain unclear. Methods The plasma H2S levels were measured in 154 outpatients with type 2 diabetes and 66 outpatients without diabetes. All blood samples were collected in the outpatient department from 09:00 to 10:00. The patients had fasted from 21:00 the previous evening and had not consumed alcohol or caffeine or smoked until sample collection. The plasma H2S levels were measured using the methylene blue assay. The plasma H2S levels were determined in triplicate, and the average concentrations were calculated against a calibration curve of sodium sulfide. Results The patients with type 2 diabetes showed a progressive reduction in the plasma H2S levels (45.1±15.5 μM versus 54.0±26.4 μM, p<0.05), which paralleled poor glycemic control. There was a significant correlation between a reduction in the plasma H2S levels and the HbA1c levels (β=-0.505, p<0.01), Furthermore, a reduction in the plasma H2S levels was found to be related to a history of cardiovascular diseases in patients with type 2 diabetes (39.9±13.8 μM versus 47.5±15.9 μM, p<0.01). Conclusion Collectively, the plasma H2S levels were reduced in patients with type 2 diabetes, which may have implications in the pathophysiology of cardiovascular disease in diabetic patients. The trial was registered with the University Hospital Medical Information Network (UMIN no. #000020549). PMID:28049995

  13. Investigation on Plasma Jet Flow Phenomena During DC Air Arc Motion in Bridge-Type Contacts

    Science.gov (United States)

    Zhai, Guofu; Bo, Kai; Chen, Mo; Zhou, Xue; Qiao, Xinlei

    2016-05-01

    Arc plasma jet flow in the air was investigated under a bridge-type contacts in a DC 270 V resistive circuit. We characterized the arc plasma jet flow appearance at different currents by using high-speed photography, and two polished contacts were used to search for the relationship between roughness and plasma jet flow. Then, to make the nature of arc plasma jet flow phenomena clear, a simplified model based on magnetohydrodynamic (MHD) theory was established and calculated. The simulated DC arc plasma was presented with the temperature distribution and the current density distribution. Furthermore, the calculated arc flow velocity field showed that the circular vortex was an embodiment of the arc plasma jet flow progress. The combined action of volume force and contact surface was the main reason of the arc jet flow. supported by National Natural Science Foundation of China (Nos. 51307030, 51277038)

  14. Investigation on Plasma Jet Flow Phenomena During DC Air Arc Motion in Bridge-Type Contacts

    Institute of Scientific and Technical Information of China (English)

    ZHAI Guofu; BO Kai; CHEN Mo; ZHOU Xue; QIAO Xinlei

    2016-01-01

    Arc plasma jet flow in the air was investigated under a bridge-type contacts in a DC 270 V resistive circuit.We characterized the arc plasma jet flow appearance at different currents by using high-speed photography,and two polished contacts were used to search for the relationship between roughness and plasma jet flow.Then,to make the nature of arc plasma jet flow phenomena clear,a simplified model based on magnetohydrodynamic (MHD) theory was established and calculated.The simulated DC arc plasma was presented with the temperature distribution and the current density distribution.Furthermore,the calculated arc flow vclocity field showed that the circular vortex was an embodiment of the arc plasma jet flow progress.The combined action of volume force and contact surface was the main reason of the arc jet flow.

  15. Evaluation of random plasma glucose for assessment of glycaemic control in type 2 diabetes mellitus.

    Science.gov (United States)

    Ain, Qurratul; Latif, Atif; Jaffar, Syed Raza; Ijaz, Aamir

    2017-09-01

    To evaluate the accuracy of random plasma glucose in outpatients with type 2 diabetes mellitus for assessing glycaemic control. This comparative, cross-sectional study was conducted at the chemical pathology department of PNS Shifa Hospital, Karachi, from August 2015 to March 2016, and comprised data of subjects with type 2 diabetes mellitus who reported for evaluation of glycaemic control in non-fasting state. All blood samples were analysed for random plasma glucose and glycated haemoglobin. Random plasma glucose was compared as an index test with glycated haemoglobin considering it as reference standard at a value of less than 7% for good glycaemic control. SPSS 20 was used for data analysis. Of the 222 subjects, 93(42%) had good glycaemic control. Random plasma glucose showed strong positive correlation with glycated haemoglobin (p=0.000).Area under curve for random plasma glucose as determined by plotting receiver operating characteristic curve against glycated haemoglobin value of 7% was 0.89 (95% confidence interval: 0.849-0.930). Random plasma glucose at cut-off value of 150 mg/dl was most efficient for ruling out poor glycaemic control among patients with type 2 diabetes mellitus with 90.7% sensitivity and69.9% specificity and Youden's index of 0.606. Random plasma glucose may be used to reflect glycaemic control in adults with type 2 diabetes mellitus in areas where glycated haemoglobin is not feasible.

  16. The heliocentric radial variation of plasma oscillations associated with type III radio bursts

    Science.gov (United States)

    Gurnett, D. A.; Anderson, R. R.; Scarf, F. L.; Kurth, W. S.

    1978-01-01

    A survey is presented of all of the electron plasma oscillation events found to date in association with low-frequency type III solar radio bursts using approximately 9 years of observations from the Imp 6 and 8, Helios 1 and 2, and Voyager 1 and 2 spacecraft. Plasma oscillation events associated with type III radio bursts show a pronounced increase in both the intensity and the frequency of occurrence with decreasing heliocentric radial distance. This radial dependence explains why intense electron plasma oscillations are seldon observed in association with type III radio bursts at the orbit of the earth. Possible interpretations of the observed radial variation in the plasma oscillation intensity are considered.

  17. Wind mass transfer in S-type symbiotic binaries I. Focusing by the wind compression model

    CERN Document Server

    Skopal, Augustin

    2014-01-01

    Context: Luminosities of hot components in symbiotic binaries require accretion rates that are higher than those that can be achieved via a standard Bondi-Hoyle accretion. This implies that the wind mass transfer in symbiotic binaries has to be more efficient. Aims: We suggest that the accretion rate onto the white dwarfs (WDs) in S-type symbiotic binaries can be enhanced sufficiently by focusing the wind from their slowly rotating normal giants towards the binary orbital plane. Methods: We applied the wind compression model to the stellar wind of slowly rotating red giants in S-type symbiotic binaries. Results: Our analysis reveals that for typical terminal velocities of the giant wind, 20 to 50 km/s, and measured rotational velocities between 6 and 10 km/s, the densities of the compressed wind at a typical distance of the accretor from its donor correspond to the mass-loss rate, which can be a factor of $\\sim$10 higher than for the spherically symmetric wind. This allows the WD to accrete at rates of $10^{-...

  18. The Dense Plasma Focus Opportunities in Detection of Hidden Objects by Using Nanosecond Impulse Neutron Inspection System (NINIS)

    Science.gov (United States)

    Gribkov, V.; Dubrovsky, A.; Karpiński, L.; Miklaszewski, R.; Paduch, M.; Scholz, M.; StrzyŻewski, P.; Tomaszewski, K.

    2006-12-01

    Dense Plasma Focus device is proposed for use as a neutron source to generate very powerful pulses of neutrons in the nanosecond (ns) range of its duration. Our devices PF-6, recently put into operation at the Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland, and PF-10 belonging to the Institute for Theoretical and Experimental Physics, Moscow, Russia, have energy storages in its capacitor banks 7.4 kJ and 13 kJ as a maximum. Operated with the DPF chambers of a special design they have a current maximum up to ˜760 kA with a quarter period of the discharge equal to 1 microsecond. They generate circa 109 of 2.5-MeV neutrons in one pulse of ≅ 10-ns duration when working with deuterium, what permit to expect 1011 14-MeV neutrons at their operation with DT-mixture. This feature gives a principal possibility to create a "single-shot detection system" for interrogation of hidden objects. It means that all necessary information will be received during a single bright pulse of neutrons having duration in a nanosecond range by means of the time-of-flight technique with a short flight base. It might be a base for the creation of the Nanosecond Impulse Neutron Inspection System (NINIS). These characteristics of the neutron source open a number of opportunities while interrogation time in this case would now depend only on the data-processing system.

  19. Research on anisotropy of fusion-produced protons and neutrons emission from high-current plasma-focus discharges

    Energy Technology Data Exchange (ETDEWEB)

    Malinowski, K., E-mail: karol.malinowski@ncbj.gov.pl; Sadowski, M. J.; Szydlowski, A. [National Centre for Nuclear Research (NCBJ), 05-400 Otwock (Poland); Institute of Plasma Physics and Laser Microfusion (IFPiLM), 01-497 Warsaw (Poland); Skladnik-Sadowska, E.; Czaus, K.; Kwiatkowski, R.; Zaloga, D. [National Centre for Nuclear Research (NCBJ), 05-400 Otwock (Poland); Paduch, M.; Zielinska, E. [Institute of Plasma Physics and Laser Microfusion (IFPiLM), 01-497 Warsaw (Poland)

    2015-01-15

    The paper concerns fast protons and neutrons from D-D fusion reactions in a Plasma-Focus-1000U facility. Measurements were performed with nuclear-track detectors arranged in “sandwiches” of an Al-foil and two PM-355 detectors separated by a polyethylene-plate. The Al-foil eliminated all primary deuterons, but was penetrable for fast fusion protons. The foil and first PM-355 detector were penetrable for fast neutrons, which were converted into recoil-protons in the polyethylene and recorded in the second PM-355 detector. The “sandwiches” were irradiated by discharges of comparable neutron-yields. Analyses of etched tracks and computer simulations of the fusion-products behavior in the detectors were performed.

  20. Specific features of X-ray generation by plasma focus chambers with deuterium and deuterium-tritium fillings

    Science.gov (United States)

    Dulatov, A. K.; Krapiva, P. S.; Lemeshko, B. D.; Mikhailov, Yu. V.; Moskalenko, I. N.; Prokuratov, I. A.; Selifanov, A. N.

    2016-01-01

    The process of hard X-ray (HXR) generation in plasma focus (PF) chambers was studied experimentally. The radiation was recorded using scintillation detectors with a high time resolution and thermoluminescent detectors in combination with the method of absorbing filters. Time-resolved analysis of the processes of neutron and X-ray generation in PFs is performed. The spectra of HXR emission from PF chambers with deuterium and deuterium-tritium fillings are determined. In experiments with PF chambers filled with a deuterium-tritium mixture, in addition to the HXR pulse with photon energies of up to 200-300 keV, a γ-ray pulse with photon energies of up to 2.5-3.0 MeV is recorded, and a mechanism of its generation is proposed.

  1. Profile of saxagliptin in the treatment of type 2 diabetes: focus on Japanese patients

    Directory of Open Access Journals (Sweden)

    Konya H

    2014-07-01

    Full Text Available Hiroyuki Konya,1 Yuzo Yano,1 Satoshi Matsutani,1 Taku Tsunoda,2 Takashi Ikawa,2 Yoshiki Kusunoki,2 Toshihiro Matsuo,2 Masayuki Miuchi,2 Tomoyuki Katsuno,3 Tomoya Hamaguchi,4 Jun-ichiro Miyagawa,2 Mitsuyoshi Namba21Department of Internal Medicine, Ashiya Municipal Hospital, Ashiya, 2Division of Diabetes, Endocrinology and Metabolism, Department of Internal Medicine, 3Division of Innovative Diabetes Treatment, Hyogo College of Medicine, Nishinomiya, 4Division of Diabetes, Department of Internal Medicine, Itami City Hospital, Itami, Hyogo, JapanAbstract: Saxagliptin is a selective and potent dipeptidyl peptidase (DPP-4 inhibitor, approved as an adjunct to diet and exercise to improve glycemic control in type 2 diabetes mellitus (T2DM in the USA on July 2009, and had been launched globally in over 86 countries by September 2013. In patients with T2DM, once-daily administration of saxagliptin before breakfast achieves sustained inhibition of plasma DPP-4 activity and reduction of postprandial hyperglycemia, including after dinner, associated with an increase in plasma glucagon-like peptide-1 levels. This paper reviews the safety and efficacy of saxagliptin in Japanese patients with T2DM. The clinical development study in Japan supported its usefulness for the disease. Saxagliptin 1, 2.5, and 5 mg led to significant improvements in glycated hemoglobin (HbA1c, and was generally well tolerated. Treatment with saxagliptin 5 mg induced a sustained reduction in HbA1c over 52 weeks. Long-term combination therapy with saxagliptin and other oral hypoglycemic agents also provided sustained glycemic control and was well tolerated for up to 52 weeks. Saxagliptin as add-on to sulfonylureas or glinides has a tendency to increase hypoglycemia, but not with other oral antidiabetic agents, such as α-glucosidase inhibitors, metformin, or thiazolidinediones. The results of clinical trials have confirmed the long-term efficacy and safety of saxagliptin monotherapy as

  2. Rosiglitazone Decreases Plasma Levels of Osteoprotegerin in a Randomized Clinical Trial with Type 2 Diabetes Patients

    DEFF Research Database (Denmark)

    Nybo, Mads; Preil, Simone Rørdam; Juhl, Henning Friis

    2011-01-01

      Cardiovascular disease is the leading cause of death in patients with type 2 diabetes mellitus (T2DM). We suggested that plasma osteoprotegerin (OPG), a strong, independent predictor of cardiovascular disease, could discriminate between anti-diabetic treatments depending on their benefits....../placebo or rosiglitazone/placebo). A total of 371 individuals were eligible for the study. Basic variables were analysed along with measurement of plasma OPG and HbA(1c) at the beginning and end of the study. Only rosiglitazone treatment caused a significant decrease in plasma OPG concentrations (p = 0.003), while...... no significant change was seen in the other treatment groups. The effect of rosiglitazone on plasma OPG remained significant in a univariate analysis adjusted for change in HbA(1c) (p = 0.013). Of note, the change in plasma OPG significantly correlated with HbA(1c) improvement in rosiglitazone-treated patients...

  3. Modulation of C1-Inhibitor and Plasma Kallikrein Activities by Type IV Collagen

    OpenAIRE

    Sriram Ravindran; Marc Schapira; Patston, Philip A.

    2012-01-01

    The contact system of coagulation can be activated when in contact with biomaterials. As collagen is being tested in novel biomaterials in this study, we have investigated how type IV collagen affects plasma kallikrein and C1-inhibitor. Firstly, we showed C1-inhibitor binds to type IV collagen with a Kd of 0.86 μM. The effects of type IV collagen on plasma kallikrein, factor XIIa, and β-factor XIIa activity and on C1-inhibitor function were determined. Factor XIIa rapidly lost activity in the...

  4. Characterization of plasma etching damage on p -type GaN using Schottky diodes

    OpenAIRE

    2008-01-01

    The plasma etching damage in p-type GaN has been characterized. From current-voltage and capacitance-voltage characteristics of Schottky diodes, it was revealed that inductively coupled plasma (ICP) etching causes an increase in series resistance of the Schottky diodes and compensation of acceptors in p-type GaN. We investigated deep levels near the valence band of p-type GaN using current deep level transient spectroscopy (DLTS), and no deep level originating from the ICP etching damage was ...

  5. Acute hyperinsulinemia decreases plasma osteoprotegerin with diminished effect in type 2 diabetes and obesity

    DEFF Research Database (Denmark)

    Jørgensen, Gitte Maria; Vind, Birgitte; Nybo, Mads;

    2009-01-01

    the acute effects of insulin on plasma OPG concentrations in individuals with type 2 diabetes and obese individuals compared with lean controls. DESIGN: The study population consisted of ten type 2 diabetic, ten obese subjects, and ten lean subjects with no family history of diabetes. METHODS: All subjects...... infusion decreased plasma OPG concentrations in all groups (Pobese and type 2 diabetic individuals (P=0.007). Baseline OPG correlated with fasting insulin, baseline lactate, and low density lipoprotein cholesterol in the diabetic group, and with baseline FFA...... in the lean group. The relative change of OPG in response to insulin correlated inversely with HbA1c and baseline FFA in the lean group. CONCLUSIONS: Acute hyperinsulinemia decreases plasma OPG, but with diminished effect in individuals with type 2 diabetes and obesity. Increased levels of OPG in arteries...

  6. Evaluation of prenatal RHD typing strategies on cell-free fetal DNA from maternal plasma

    NARCIS (Netherlands)

    M.G.H.M. Grootkerk-Tax; A.A. Soussan; M. de Haas; P.A. Maaskant-van Wijk; C.E. van der Schoot

    2006-01-01

    BACKGROUND: The discovery of cell-free fetal DNA in maternal plasma led to the development of assays to predict the fetal D status with RHD-specific sequences. Few assays are designed in such a way that the fetus can be typed in RHD psi mothers and that RHD psi fetuses are correctly typed. Owing to

  7. Deposition of Chromium Thin Films on Stainless Steel-304 Substrates Using a Low Energy Plasma Focus Device

    Science.gov (United States)

    Javadi, S.; Ghoranneviss, M.; Hojabri, A.; Habibi, M.; Hosseinnejad, M. T.

    2012-06-01

    In this paper, we study thin films of chromium deposited on stainless steel-304 substrates using a low energy (1.6 kJ) plasma focus device. The films of chromium are likewise deposited with 25 focus shots each at various axial distances from the top of the anode (3, 5, 7, 9 and 11 cm). We also consider different angular positions with respect to the anode axis (0°, 15° and 30°) at a distance of 5 cm from the anode tip to deposit the chromium films on the stainless steel substrates. To characterize the structural properties of the films, we benefit from X-ray diffraction (XRD) analysis. Atomic force microscopy (AFM) and scanning electron microscopy (SEM) are applied as well to study the surface morphology of these deposited films. Furthermore, we make use of Vicker's micro-hardness measurements to investigate the mechanical properties of chromium thin films. The XRD results show that the degree of crystallinity of chromium thin films depends on the substrate axial and angular positions. The AFM images illustrate that the film deposited at the distance of 5 cm and the angular position of 0° has quite a uniform surface with homogeneous distribution of grains on the film surface. From the hardness results, we observe that the sample deposited at the axial distance of 5 cm from the anode tip and at the angle of 0° with respect to the anode axis, is harder than the other deposited films.

  8. Plasma adrenaline kinetics in type 1 (insulin-dependent) diabetic patients with and without autonomic neuropathy

    DEFF Research Database (Denmark)

    Dejgaard, Anders; Hilsted, J; Henriksen, J H

    1989-01-01

    Plasma adrenaline kinetics (clearance, extraction across the forearm, initial plasma disappearance rate, mean sojourn time, volume of distribution) were studied in sixteen Type 1 (insulin-dependent) diabetic patients during constant i.v. infusion of tritium labelled adrenaline. In patients with (n...... = 8) and without (n = 8) neuropathy forearm venous plasma noradrenaline and adrenaline concentrations as well as plasma clearance of adrenaline based on arterial sampling (1.7 vs 2.1 l/min) were not significantly different. The initial disappearance time (T 1/2) after the infusion of the tritium...... labelled adrenaline had been stopped was significantly prolonged in Type 1 diabetic patients with neuropathy compared to those without (after 20 min infusion 2.7 vs 2.2 min, p less than 0.02, after 75 min infusion 3.7 vs 2.9 min, p less than 0.05). The corresponding values for the mean sojourn time...

  9. Quantitative iTRAQ-Based Proteomic Identification of Candidate Biomarkers for Diabetic Nephropathy in Plasma of Type 1 Diabetic Patients

    DEFF Research Database (Denmark)

    Overgaard, Anne Julie; Thingholm, Tine Engberg; Larsen, Martin R

    2010-01-01

    INTRODUCTION: As part of a clinical proteomics programme focused on diabetes and its complications, it was our goal to investigate the proteome of plasma in order to find improved candidate biomarkers to predict diabetic nephropathy. METHODS: Proteins derived from plasma from a cross...... immunoassay confirmed the overall protein expression patterns observed by the iTRAQ analysis. CONCLUSION: The candidate biomarkers discovered in this cross-sectional cohort may turn out to be progression biomarkers and might have several clinical applications in the treatment and monitoring of diabetic......-sectional cohort of 123 type 1 diabetic patients previously diagnosed as normoalbuminuric, microalbuminuric or macroalbuminuric were enriched with hexapeptide library beads and subsequently pooled within three groups. Proteins from the three groups were compared by online liquid chromatography and tandem mass...

  10. A nut-type ultrasonic motor and its application in the focus system

    Institute of Scientific and Technical Information of China (English)

    ZHOU TieYing; ZHANG Yun; CHEN Yu; LU CunYue; FU DeYong; LI Yi; HU XiaoPing

    2009-01-01

    This article reports a screw-driven polyhedron linear ultrasonic motor (USM) of nut-type. It is comprised of a stator, which is a threaded metal nut bonded with piezoelectric plates on its external surface, and a rotor with external threads, which engage with the internal threads of the stator. A traveling wave in the plane is stimulated on the stator when harmonic electric signals are applied to the piezoelectric plates. The traveling wave drives the rotor to rotate, and the threads transform the rotation into a linear motion. The lens can be fixed in the rotor and realize the integrated design of the auto focus system. This structure can omit retarder and directly drive to obtain a high accuracy of positioning, and it is shock-proof. A mini AF cellular phone module (8.5 mm×8.5 mm×5.9 mm) driven by this motor was made and an image resolution of 3 5 MP was obtained in the module prototypes of the cellular phone.

  11. [Medicinal chemistry and pharmacology focused on cannabidiol, a major component of the fiber-type cannabis].

    Science.gov (United States)

    Takeda, Shuso

    2013-01-01

    Considerable attention has focused on cannabidiol (CBD), a major non-psychotropic constituent of fiber-type cannabis plant, and it has been reported to possess diverse biological activities. Although CBD is obtained from non-enzymatic decarboxylation of its parent molecule, cannabidiolic acid (CBDA), several studies have investigated whether CBDA itself is biologically active. In the present report, the author summarizes findings indicating that; 1) CBDA is a selective cyclooxygenase-2 (COX-2) inhibitor, and ii) CBDA possesses an anti-migrative potential for highly invasive cancer cells, apparently through a mechanism involving inhibition of cAMP-dependent protein kinase A, coupled with an activation of the small GTPase, RhoA. Further, the author introduces recent findings on the medicinal chemistry and pharmacology of the CBD derivative, CBD-2',6'-dimethyl ether (CBDD), that exhibits inhibitory activity toward 15-lipoxygenase (15-LOX), an enzyme responsible for the production of oxidized low-density lipoprotein (LDL). These studies establish CBD as both an important experimental tool and as a lead compound for pharmaceutical development. In this review, the author further discusses the potential uses of CBD and its derivatives in future medicines.

  12. Dense Plasma Focus Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hui [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Li, Shengtai [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jungman, Gerard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hayes-Sterbenz, Anna Catherine [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-10

    Here we report on high-fidelity 2D and 3D numerical magnetohydrodynamic (MHD) simulations using the LA-COMPASS code to study the pinch formation dynamics in a DPF and the associated instabilities and neutron production.

  13. Exploring types of focused factories in hospital care: a multiple case study.

    NARCIS (Netherlands)

    Bredenhoff, E.; Bredenhoff, Eelco; van Lent, W.A.M.; van Harten, Willem H.

    2010-01-01

    Background: Focusing on specific treatments or diseases is proposed as a way to increase the efficiency of hospital care. The definition of "focus" or "focused factory", however, lacks clarity. Examples in health care literature relate to very different organizations. Our aim was to explore the

  14. A new type of plasma knife and its effect on biological issues--a pilot study.

    Science.gov (United States)

    Justan, I; Tichý, F; Slavícek, P

    2010-01-01

    Currently, several types of plasma discharge devices have become established for performing surgical procedures or superficial sterilization. Our goal is to introduce a brand new type of plasma discharge device with different characteristics, which we have used for two experiments involving thermal damage to biological tissues. A plasma discharge device with the following characteristics was used for all incisions in plasma group: radio frequency barrier discharger at atmospheric pressure with a working frequency of 13.56 MHz. The working gas was Argon. We used a Cesar 136 generator with typical power 100-150W and with a working gas flow rate between 0.5 and 3 litres per minute. The inner diameter of the end of the nozzle was 0.4mm. A standard Martin electrotome was used for all comparative incisions in the electrotome group. We used two experimental fresh rat cadavers, employing their skin, tails, lungs, livers, kidneys and spleens to make a comparative study between incisions made with a plasma discharge knife and those made with a standard electrotome device. All samples underwent histological verification. Our experiment showed slight differences in the impact on incision edges made by the plasma knife and the electrotome. The most interesting effect is on the skin: the plasma knife does not damage hair bulbs, and it results in less thermal damage. The plasma discharge knife is a promising device for cutting various biological tissues. Its effect can be compared with a standard electrotome, while in some tissues it causes less harm then an electrotome. Moreover, we can adjust its therapeutic effect. However, we do not consider the plasma knife a better choice at present, because maneuvering it is unwieldy.

  15. Comparing transfusion reaction rates for various plasma types: a systematic review and meta-analysis/regression.

    Science.gov (United States)

    Saadah, Nicholas H; van Hout, Fabienne M A; Schipperus, Martin R; le Cessie, Saskia; Middelburg, Rutger A; Wiersum-Osselton, Johanna C; van der Bom, Johanna G

    2017-09-01

    We estimated rates for common plasma-associated transfusion reactions and compared reported rates for various plasma types. We performed a systematic review and meta-analysis of peer-reviewed articles that reported plasma transfusion reaction rates. Random-effects pooled rates were calculated and compared between plasma types. Meta-regression was used to compare various plasma types with regard to their reported plasma transfusion reaction rates. Forty-eight studies reported transfusion reaction rates for fresh-frozen plasma (FFP; mixed-sex and male-only), amotosalen INTERCEPT FFP, methylene blue-treated FFP, and solvent/detergent-treated pooled plasma. Random-effects pooled average rates for FFP were: allergic reactions, 92/10(5) units transfused (95% confidence interval [CI], 46-184/10(5) units transfused); febrile nonhemolytic transfusion reactions (FNHTRs), 12/10(5) units transfused (95% CI, 7-22/10(5) units transfused); transfusion-associated circulatory overload (TACO), 6/10(5) units transfused (95% CI, 1-30/10(5) units transfused); transfusion-related acute lung injury (TRALI), 1.8/10(5) units transfused (95% CI, 1.2-2.7/10(5) units transfused); and anaphylactic reactions, 0.8/10(5) units transfused (95% CI, 0-45.7/10(5) units transfused). Risk differences between plasma types were not significant for allergic reactions, TACO, or anaphylactic reactions. Methylene blue-treated FFP led to fewer FNHTRs than FFP (risk difference = -15.3 FNHTRs/10(5) units transfused; 95% CI, -24.7 to -7.1 reactions/10(5) units transfused); and male-only FFP led to fewer cases of TRALI than mixed-sex FFP (risk difference = -0.74 TRALI/10(5) units transfused; 95% CI, -2.42 to -0.42 injuries/10(5) units transfused). Meta-regression demonstrates that the rate of FNHTRs is lower for methylene blue-treated compared with FFP, and the rate of TRALI is lower for male-only than for mixed-sex FFP; whereas no significant differences are observed between plasma types for allergic

  16. Multicusp type Electron Cyclotron Resonance ion source for plasma processing

    Energy Technology Data Exchange (ETDEWEB)

    Amemiya, Hiroshi; Shigueoka, Yoshyuki (Institute of Physical and Chemical Research, Wako, Saitama (Japan)); Ishii, Shigeyuki

    1991-02-01

    A multi-cusp type ECR (electron cyclotron resonance) ion source is built with use of SmCo magnets and 2.45 GHz-TE{sub 11} circular mode microwave. The ion source is operated at pressures from 10{sup -4} to 10{sup -3} Torr with the input microwave power from 100 to 400 W. In hydrogen, the current density of H{sup +} is higher than those of H{sub 2}{sup +} and H{sub 3}{sup +}. The dependence of the fraction of each ion species on the power and pressure is measured and explained by rate equations. The source is operated also in other gases. Mass spectra in He, N{sub 2}, O{sub 2}, Ar and CH{sub 4} are shown together with the pressure and power dependences. Multicharged state of up to 3 has been obtained. (author).

  17. At wavelength focusing properties evaluation of the Wolter type grazing incidence mirror

    CERN Document Server

    Takeuchi, A; Uesugi, K; Aoki, S

    2001-01-01

    Focusing properties of a Wolter mirror were evaluated in a hard X-ray region (approx 10 keV). Although the sagittal focal spot size was found to be 0.7 mu m, some spots are spread in meridional direction within a range of over 100 mu m. A Foucault-test method has been employed for closer investigation of the focusing properties. Wave-front of the sagittal focusing rays was almost ideal. On the contrary, it was found that slope error of about 100-300 mu rad existed for the meridional focusing.

  18. Energy- and time-resolved measurements of fast ions emitted from plasma-focus discharges by means of a Thomson spectrometer

    Science.gov (United States)

    Kwiatkowski, R.; Czaus, K.; Paduch, M.; Sadowski, M. J.; Skladnik-Sadowska, E.; Zaloga, D. R.; Zielinska, E.; Żebrowski, J.

    2015-09-01

    The paper presents results of time-resolved measurements of fast deuterons emitted from high-current discharges of the Plasma-Focus (PF) type. The measurements were performed in a modified PF-1000U facility which is operated at the IFPiLM in Warsaw, Poland. The device was equipped with a fast-acting gas valve placed inside the inner electrode and oriented along the z-axis. The valve could inject a small volume of a chosen gas in front of this electrode. The PF discharges were initiated at the initial deuterium pressure equal to 1.6 or 2 hPa, with or without the use of the gas-puffing. Such discharges emitted intense beams of accelerated primary ions and X-ray pulses as well as products of nuclear fusion reactions. The reported measurements of the fast ion beams were performed by means of a Thomson-type spectrometer located at a chosen distance at the z-axis and equipped with miniature scintillation detectors. These detectors were placed in different points upon the deuteron parabola which corresponded to determined energy values. The detectors configuration allowed us to determine instants of the ion emission (using a TOF technique) and to compare them with instants of the X-ray emission. The collected data provided important information about emission characteristics of the modified PF-1000U facility.

  19. Plasma Kinetics in the Ethanol/Water/Air Mixture in "Tornado" Type Electrical Discharge

    CERN Document Server

    Levko, D; Chernyak, V; Olszewski, S; Nedybaliuk, O

    2011-01-01

    This paper presents the results of a theoretical and experimental study of plasma-assisted reforming of ethanol into molecular hydrogen in a new modification of the "tornado" type electrical discharge. Numerical modeling clarifies the nature of the non-thermal conversion and explains the kinetic mechanism of nonequilibrium plasma-chemical transformations in the gas-liquid system and the evolution of hydrogen during the reforming as a function of discharge parameters and ethanol-to-water ratio in the mixture. We also propose a scheme of chemical reactions for plasma kinetics description. It is shown that some characteristics of the investigated reactor are at least not inferior to characteristics of other plasma chemical reactors.

  20. Plasma adiponectin concentrations are associated with dietary glycemic index in Malaysian patients with type 2 diabetes.

    Science.gov (United States)

    Loh, Beng-In; Sathyasuryan, Daniel Robert; Mohamed, Hamid Jan Jan

    2013-01-01

    Adiponectin, an adipocyte-derived hormone has been implicated in the control of blood glucose and chronic inflammation in type 2 diabetes. However, limited studies have evaluated dietary factors on plasma adiponectin levels, especially among type 2 diabetic patients in Malaysia. The aim of this study was to investigate the influence of dietary glycemic index on plasma adiponectin concentrations in patients with type 2 diabetes. A cross-sectional study was conducted in 305 type 2 diabetic patients aged 19-75 years from the Penang General Hospital, Malaysia. Socio-demographic information was collected using a standard questionnaire while dietary details were determined by using a pre-validated semi-quantitative food frequency questionnaire. Anthropometry measurement included weight, height, BMI and waist circumference. Plasma adiponectin concentrations were measured using a commercial ELISA kit. Data were analyzed using multiple linear regression. After multivariate adjustment, dietary glycemic index was inversely associated with plasma adiponectin concentrations (β =-0.272, 95% CI -0.262, - 0.094; pglycemic index that plasma adiponectin level reduced by 0.3 μg/mL. Thirty two percent (31.9%) of the variation in adiponectin concentrations was explained by age, sex, race, smoking status, BMI, waist circumference, HDL-C, triglycerides, magnesium, fiber and dietary glycemic index according to the multiple linear regression model (R2=0.319). These results support the hypothesis that dietary glycemic index influences plasma adiponectin concentrations in patients with type 2 diabetes. Controlled clinical trials are required to confirm our findings and to elucidate the underlying mechanism.

  1. Determination of protein carbonyls in plasma, cell extracts, tissue homogenates, isolated proteins: Focus on sample preparation and derivatization conditions.

    Science.gov (United States)

    Weber, Daniela; Davies, Michael J; Grune, Tilman

    2015-08-01

    Protein oxidation is involved in regulatory physiological events as well as in damage to tissues and is thought to play a key role in the pathophysiology of diseases and in the aging process. Protein-bound carbonyls represent a marker of global protein oxidation, as they are generated by multiple different reactive oxygen species in blood, tissues and cells. Sample preparation and stabilization are key steps in the accurate quantification of oxidation-related products and examination of physiological/pathological processes. This review therefore focuses on the sample preparation processes used in the most relevant methods to detect protein carbonyls after derivatization with 2,4-dinitrophenylhydrazine with an emphasis on measurement in plasma, cells, organ homogenates, isolated proteins and organelles. Sample preparation, derivatization conditions and protein handling are presented for the spectrophotometric and HPLC method as well as for immunoblotting and ELISA. An extensive overview covering these methods in previously published articles is given for researchers who plan to measure protein carbonyls in different samples.

  2. The effect of pre-ionization by a shunt resistor on the reproducibility of plasma focus x-ray emission

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, S [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Sadiq, Mehboob [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Shafiq, M [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Waheed, A [PINSTECH, PO Box 2151, 44000 Islamabad (Pakistan); Lee, P [Natural Sciences Academics Group, National Institute of Education, Nanyang Technological University, 1 Nanyang Walk, 637616 (Singapore); Zakaullah, M [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan)

    2006-08-15

    The effect of pre-ionization by means of a shunt resistor on the x-ray emission of a low energy (1.8 kJ) plasma focus device powered by a 9 {mu}F capacitor bank, charged at 20 kV and giving a peak discharge current of about 175 kA is investigated. Quantrad Si pin-diodes along with a suitable filter are employed as time-resolved x-ray detectors, whereas a multipinhole camera with absorption filters is used for time-integrated analysis. X-ray flux in 4{pi}-geometry is measured as a function of argon filling pressure with and without pre-ionization. It is found that appropriate selection of the shunt resistor increases shot-to-shot reproducibility of the x-ray emission as well as the stability of the pinch filament and broadens the x-ray pulse width. The x-ray emission is also enhanced by (45 {+-} 5)% at the optimum pressure.

  3. Knowing the dense plasma focus - The coming of age (of the PF) with broad-ranging scaling laws

    Science.gov (United States)

    Saw, S. H.; Lee, S.

    2017-03-01

    The dense plasma focus is blessed not only with copious multi-radiations ranging from electron and ion beams, x-rays both soft and hard, fusion neutrons D-D and D-T but also with the property of enhanced compression from radiative collapse leading to HED (high energy density) states. The Lee code has been used in extensive systematic numerical experiments tied to reality through fitting with measured current waveforms and verified through comparison of measured and computed yields and measurements of multi-radiation. The studies have led to establishment of scaling laws with respect to storage energy, discharge current and pinch currents for fusion neutrons, characteristic soft x-rays, all-line radiation and ion beams. These are summarized here together with a first-time presentation of a scaling law of radiatively enhanced compression as a function of atomic number of operational gas. This paper emphasizes that such a broad range of scaling laws signals the coming of age of the DPF and presents a reference platform for planning the many potential applications such as in advanced SXR lithography, materials synthesizing and testing, medical isotopes, imaging and energy and high energy density (HED).

  4. Effect of deposition parameters on structural and mechanical properties of niobium nitride synthesized by plasma focus device

    Science.gov (United States)

    Siddiqui, Jamil; Hussain, Tousif; Ahmad, Riaz; Khalid, Nida

    2015-06-01

    Effects of deposition angle and axial distance on the structural and mechanical properties of niobium nitride synthesized by a dense plasma focus (DPF) system are studied. The x-ray diffraction (XRD) confirms that the deposition parameters affect the growth of multi-phase niobium nitride. Scanning electron microscopy (SEM) shows the granular surface morphology with strong thermally assisted coagulation effects observed at the 5-cm axial distance. The non-porous granular morphology observed at the 9-cm distance along the anode axis is different from those observed at deposition angles of 10° and 20°. Energy dispersive x-ray (EDX) spectroscopy reveals the maximum nitrogen content at the shortest (5 cm) axial position. Atomic force microscopy (AFM) exhibits that the roughness of coated films varies for coatings synthesized at different axial and angular positions, and the Vickers micro-hardness test shows that a maximum hardness value is (08.44 ± 0.01) GPa for niobium nitride synthesized at 5-cm axial distance, which is about 500% more than that of a virgin sample. Project supported by the HEC, Pakistan.

  5. EBT2 Dosimetry of X-rays produced by the electron beam from PFMA-3, a Plasma Focus for medical applications

    CERN Document Server

    Ceccolini, Elisa; Mostacci, Domiziano; Sumini, Marco; Tartari, Agostino

    2011-01-01

    The electron beam emitted from the back of Plasma Focus devices is being studied as a radiation source for IORT (IntraOperative Radiation Therapy) applications. A Plasma Focus device is being developed to this aim, to be utilized as an X-ray source. The electron beam is driven to impinge on 50 {\\mu}m brass foil, where conversion X-rays are generated. Measurements with gafchromic film are performed to analyse the attenuation of the X-rays beam and to predict the dose given to the culture cell in radiobiological experiments to follow.

  6. Negative interference by rheumatoid factor of plasma B-type natriuretic peptide in chemiluminescent microparticle immunoassays.

    Directory of Open Access Journals (Sweden)

    Wen Fan

    Full Text Available BACKGROUND: The chemiluminescent microparticle immunoassay (CMIA is widely used for the quantitative determination of B-type natriuretic peptide (BNP in human ethylenediaminetetraacetic acid plasma. Rheumatoid factor (RF is usually thought to result in a positive interference in immunoassays, but it is not clear whether its presence in plasma can lead to interferences in the CMIA of BNP. METHODS: The estimation of BNP recovery was carried out by diluting high-concentration BNP samples with RF-positive or RF-negative plasma at a ratio of 1:9. The diluted samples were then tested using the ARCHITECT i2000 System and ARCHITECT BNP Reagent Kits and the recovery was then calculated. RESULTS: When the RF level ranged from 48 to 1420 IU/mL, the average recovery of BNP was 79.29% and 91.61% in the RF-positive and RF-negative plasma samples, respectively, and was thus significantly lower in the group of RF-positive plasma samples than in the group of RF-negative plasma samples. At a dilution of 1:16, the measured BNP level increased by >36% in six of the seven RF-positive plasma samples. The recovery of BNP increased significantly in the RF-positive plasma samples after pretreatment with IgG-sensitive latex particles. In addition, The BNP recovery was not significantly related to the plasma RF at concentrations ranging from 48 to 2720 IU/mL. CONCLUSIONS: Measurement of BNP by CMIA is susceptible to interference from RF leading to predominantly (but not exclusively lower results. Pretreatment of samples with blocking reagents is advisable prior to the initiation of denying patient's necessary treatment.

  7. Negative interference by rheumatoid factor of plasma B-type natriuretic peptide in chemiluminescent microparticle immunoassays.

    Science.gov (United States)

    Fan, Wen; Xu, Lei; Xie, Liangcai; Yang, Decai; Liu, Xuezheng; Zhang, Jiajun; Li, Yirong; Yi, Cunjian

    2014-01-01

    The chemiluminescent microparticle immunoassay (CMIA) is widely used for the quantitative determination of B-type natriuretic peptide (BNP) in human ethylenediaminetetraacetic acid plasma. Rheumatoid factor (RF) is usually thought to result in a positive interference in immunoassays, but it is not clear whether its presence in plasma can lead to interferences in the CMIA of BNP. The estimation of BNP recovery was carried out by diluting high-concentration BNP samples with RF-positive or RF-negative plasma at a ratio of 1:9. The diluted samples were then tested using the ARCHITECT i2000 System and ARCHITECT BNP Reagent Kits and the recovery was then calculated. When the RF level ranged from 48 to 1420 IU/mL, the average recovery of BNP was 79.29% and 91.61% in the RF-positive and RF-negative plasma samples, respectively, and was thus significantly lower in the group of RF-positive plasma samples than in the group of RF-negative plasma samples. At a dilution of 1:16, the measured BNP level increased by >36% in six of the seven RF-positive plasma samples. The recovery of BNP increased significantly in the RF-positive plasma samples after pretreatment with IgG-sensitive latex particles. In addition, The BNP recovery was not significantly related to the plasma RF at concentrations ranging from 48 to 2720 IU/mL. Measurement of BNP by CMIA is susceptible to interference from RF leading to predominantly (but not exclusively) lower results. Pretreatment of samples with blocking reagents is advisable prior to the initiation of denying patient's necessary treatment.

  8. Borrmann Type 4 Advanced Gastric Cancer: Focus on the Development of Scirrhous Gastric Cancer

    OpenAIRE

    Jung, Kyoungwon; Park, Moo In; Kim, Sung Eun; Park, Seun Ja

    2016-01-01

    Early diagnosis of Borrmann type 4 advanced gastric cancer (AGC) is very important for improving the prognosis of AGC patients. Because there is no definite mass in most cases of Borrmann type 4 AGC, its accurate diagnosis via endoscopy requires an understanding of its pathogenesis and developmental process. Moreover, many people confuse linitis plastica (LP) type gastric cancer (GC), scirrhous GC, and Borrmann type 4 AGC. To distinguish each of these cancers, knowledge of their endoscopic an...

  9. Plasma lipid profiling shows similar associations with prediabetes and type 2 diabetes.

    Directory of Open Access Journals (Sweden)

    Peter J Meikle

    Full Text Available The relationship between lipid metabolism with prediabetes (impaired fasting glucose and impaired glucose tolerance and type 2 diabetes mellitus is poorly defined. We hypothesized that a lipidomic analysis of plasma lipids might improve the understanding of this relationship. We performed lipidomic analysis measuring 259 individual lipid species, including sphingolipids, phospholipids, glycerolipids and cholesterol esters, on fasting plasma from 117 type 2 diabetes, 64 prediabetes and 170 normal glucose tolerant participants in the Australian Diabetes, Obesity and Lifestyle Study (AusDiab then validated our findings on 1076 individuals from the San Antonio Family Heart Study (SAFHS. Logistic regression analysis of identified associations with type 2 diabetes (135 lipids and prediabetes (134 lipids, after adjusting for multiple covariates. In addition to the expected associations with diacylglycerol, triacylglycerol and cholesterol esters, type 2 diabetes and prediabetes were positively associated with ceramide, and its precursor dihydroceramide, along with phosphatidylethanolamine, phosphatidylglycerol and phosphatidylinositol. Significant negative associations were observed with the ether-linked phospholipids alkylphosphatidylcholine and alkenylphosphatidylcholine. Most of the significant associations in the AusDiab cohort (90% were subsequently validated in the SAFHS cohort. The aberration of the plasma lipidome associated with type 2 diabetes is clearly present in prediabetes, prior to the onset of type 2 diabetes. Lipid classes and species associated with type 2 diabetes provide support for a number of existing paradigms of dyslipidemia and suggest new avenues of investigation.

  10. Effects of focus of attention and type of practice on learning and self-efficacy in dart throwing.

    Science.gov (United States)

    Shafizadeh, Mohsen; Platt, Geoffrey K; Bahram, Abbas

    2013-08-01

    The present investigation studied the effect of focus of attention and type of practice on self-efficacy and learning during a demonstration of the dart-throwing skill. 48 university students (M = 22.5 yr., SD = 3.6) without any experience of dart throwing were divided into four groups according to the type of practice (physical and observational) and focus of attention (internal and external) and practiced a dart-throwing task. Self-efficacy in dart throwing was measured at the pre-test, acquisition, and transfer phases. The internal-focus group concentrated on their limb function, whereas the external-focus group concentrated on the darts and the target during the demonstration. Observational groups only watched during the acquisition phase, then performed the task in the retention and transfer phases. There was a main effect of focus of attention in the retention and transfer phases after controlling self-efficacy, with external focus groups showing higher performance than internal focus groups. External focus of attention could facilitate the acquisition of a motor skill during observation and may build and/or be supported by self-efficacy.

  11. Type 2 diabetes associated changes in the plasma non-esterified fatty acids, oxylipins and endocannabinoids

    Science.gov (United States)

    Type 2 diabetes (T2D) has profound effects on metabolism that can be detected in plasma. While increases in circulating non-esterified fatty acids (NEFA) are well described in T2D, effects on circulating signaling lipids have received little attention. Oxylipins and endocannabinoids are classes of ...

  12. Impact of hemoglobin on plasma pro-B-type natriuretic peptide concentrations in the general population

    DEFF Research Database (Denmark)

    Nybo, Mads; Benn, Marianne; Mogelvang, Rasmus

    2007-01-01

    Age, sex, and renal function contribute to variations in plasma concentrations of B-type natriuretic peptide (BNP) and its molecular precursor (proBNP). Recent studies indicate that anemia may also affect proBNP concentrations in patients with heart failure or stroke. However, the impact...

  13. A self-focusing, high transformer ratio, collinear plasma dielectric wakefield accelerator driven by a ramped bunch train

    Science.gov (United States)

    Sotnikov, Gennadij V.; Marshall, Thomas C.; Shchelkunov, Sergey V.; Hirshfield, Jay L.

    2017-03-01

    New results of studies of wakefield excitation by a ramped bunch train in a collinear, single-channel dielectriclined THz-wakefield accelerator structure that is filled with a low-temperature plasma are presented. A novel ramped train of drive bunches, together with plasma filling part of the transport channel, makes possible substantial improvement of the transformer ratio of the multimode collinear device to 6:1 while the plasma could stabilize the transverse motion of the drive and witness bunches.

  14. An example of genetically distinct HIV type 1 variants in cerebrospinal fluid and plasma during suppressive therapy

    OpenAIRE

    Dahl, V.; Gisslen, M.; Hagberg, L.; Peterson, J.; Shao, W.; Spudich, S.; Price, RW; Palmer, S.

    2014-01-01

    We sequenced the genome of human immunodeficiency virus type 1 (HIV-1) recovered from 70 cerebrospinal fluid (CSF) specimens and 29 plasma samples and corresponding samples obtained before treatment initiation from 17 subjects receiving suppressive therapy. More CSF sequences than plasma sequences were hypermutants. We determined CSF sequences and plasma sequences in specimens obtained from 2 subjects after treatment initiation. In one subject, we found genetically distinct CSF and plasma seq...

  15. U-Shaped Association between Plasma Manganese Levels and Type 2 Diabetes.

    Science.gov (United States)

    Shan, Zhilei; Chen, Sijing; Sun, Taoping; Luo, Cheng; Guo, Yanjun; Yu, Xuefeng; Yang, Wei; Hu, Frank B; Liu, Liegang

    2016-12-01

    Manganese is both an essential element and a known toxicant, and it plays important roles in many mechanisms in relation to type 2 diabetes (T2D). However, epidemiological studies of this relationship are rare. We investigated the association between plasma manganese and newly diagnosed T2D as well as whether the association could be modified by manganese superoxide dismutase (MnSOD) polymorphisms. We conducted a case-control study of 3,228 participants in China: 1,614 T2D patients and 1,614 controls. Concentrations of plasma magnesium were measured, and all participants were genotyped for the MnSOD Val16Ala polymorphism (rs4880). A U-shaped association was observed between plasma manganese and T2D, with increased odds ratios (ORs) in relation to either low or high plasma manganese levels. Compared with the middle tertile, the multivariate-adjusted ORs [95% confidence intervals (CIs)] of T2D associated with the lowest tertile and the highest tertile of plasma manganese were 1.89 (1.53, 2.33) and 1.56 (1.23, 1.97), respectively. In spline analysis, the U-shaped association was consistently indicated, with the lowest odds of T2D at the plasma manganese concentration of 4.95 μg/L. Minor allele frequencies (C allele) of the MnSOD Val16Ala polymorphism (rs4880) in the normal glucose tolerance (NGT) and the T2D groups were 13.57% and 14.50%, respectively. The MnSOD rs4880 polymorphism was not associated with T2D, and no interaction was found between plasma manganese and the MnSOD rs4880 polymorphism in relation to T2D. Our results suggested a U-shaped association between plasma manganese and T2D; both low and high levels of plasma manganese were associated with higher odds of newly diagnosed T2D. The U-shaped association was not modified by the MnSOD rs4880 polymorphism. Citation: Shan Z, Chen S, Sun T, Luo C, Guo Y, Yu X, Yang W, Hu FB, Liu L. 2016. U-shaped association between plasma manganese levels and type 2 diabetes. Environ Health Perspect 124:1876-1881;

  16. Increased plasma N-glycome complexity is associated with higher risk of type 2 diabetes.

    Science.gov (United States)

    Keser, Toma; Gornik, Ivan; Vučković, Frano; Selak, Najda; Pavić, Tamara; Lukić, Edita; Gudelj, Ivan; Gašparović, Hrvoje; Biočina, Bojan; Tilin, Therese; Wennerström, Annika; Männistö, Satu; Salomaa, Veikko; Havulinna, Aki; Wang, Wei; Wilson, James F; Charutvedi, Nishi; Perola, Markus; Campbell, Harry; Lauc, Gordan; Gornik, Olga

    2017-09-13

    Better understanding of type 2 diabetes and its prevention is a pressing need. Changes in human plasma N-glycome are associated with many diseases and represent promising diagnostic and prognostic biomarkers. Variations in glucose metabolism directly affect glycosylation through the hexosamine pathway but studies of plasma glycome in type 2 diabetes are scarce. The aim of this study was to determine whether plasma protein N-glycome is changed in individuals who are at greater risk of developing type 2 diabetes. Using a chromatographic approach, we analysed N-linked glycans from plasma proteins in two populations comprising individuals with registered hyperglycaemia during critical illness (increased risk for development of type 2 diabetes) and individuals who stayed normoglycaemic during the same condition: AcuteInflammation (59 cases vs 49 controls) and AcuteInflammation Replication (52 cases vs 14 controls) populations. N-glycome was also studied in individuals from FinRisk (37 incident cases of type 2 diabetes collected at baseline vs 37 controls), Orkney Complex Disease Study (ORCADES; 94 individuals with HbA1c > 6.5% [47.5 mmol/mol] vs 658 controls) and Southall and Brent Revisited (SABRE) cohort studies (307 individuals with HbA1c > 6.5% [47.5 mmol/mol] vs 307 controls). Individuals with increased risk for diabetes type 2 development (AcuteInflammation and AcuteInflammation Replication populations), incident cases of type 2 diabetes collected at baseline (FinRisk population) and individuals with elevated HbA1c (ORCADES and SABRE populations) all presented with increased branching, galactosylation and sialylation of plasma protein N-glycans and these changes were of similar magnitude. Increased complexity of plasma N-glycan structures is associated with higher risk of developing type 2 diabetes and poorer regulation of blood glucose levels. Although further research is needed, this finding could offer a potential new approach for improvement in prevention

  17. The Role of Task Type in Foreign Language Written Production: Focusing on Fluency, Complexity, and Accuracy

    Science.gov (United States)

    Rezazadeh, Mohsen; Tavakoli, Mansoor; Rasekh, Abbas Eslami

    2011-01-01

    The aim of this study was to investigate the effects of two task types on foreign language written production. Particularly it addressed the issue of how three aspects of language production (i.e. fluency, complexity, and accuracy) vary among two different task types (i.e. argumentative writing task and instruction writing task). One hundred sixty…

  18. The Type of Fat Ingested at Breakfast Influences the Plasma Lipid Profile of Postmenopausal Women

    Directory of Open Access Journals (Sweden)

    J. M. Morillas-Ruiz

    2014-01-01

    Full Text Available To assess whether the type of fat ingested at breakfast can modify the plasma lipid profile and other cardiovascular risk variables in postmenopausal women at risk of cardiovascular disease, a longitudinal, randomized, and crossover study was carried out with postmenopausal women at risk of CVD. They were randomly assigned to eat each type of breakfast during one month: 6 study periods (breakfast with the same composition plus butter/margarine/virgin olive oil separated by two washout periods. On the first and last days of each study period, weight, arterial blood pressure, heart rate, and body mass index were recorded in fasting conditions and a blood sample was collected to measure plasma lipid profile. When comparing final values to baseline values, we only found out statistically significant differences on plasma lipid profiles. Butter-based breakfast increased total cholesterol and HDL, while margarine-based breakfast decreased total cholesterol and LDL and increased HDL. After the olive oil-based breakfast intake, a tendency towards a decrease of total cholesterol and LDL levels and an increase of HDL levels was observed. No statistically significant differences were observed in triglycerides levels, BMI, and arterial pressure in any breakfast type. The margarine-based breakfast was the only one which significantly increased the percentage of volunteers with optimal lipid profiles. The polyunsaturated fat at breakfast has improved the plasma lipid profile in the analyzed sample population, suggesting that PUFA-based breakfast can be advisable in women at risk of CVD.

  19. MIXED HYALINE VASCULAR AND PLASMA CELL TYPE CASTLEMAN’S DISEASE: REPORT OF A CASE

    Directory of Open Access Journals (Sweden)

    F. Asgarani

    2006-05-01

    Full Text Available Castleman’s disease (angiofollicular lymphoid hyperplasia includes a heterogeneous group of lymphoproliferative disorders. The cause of this disease remains uncertain. There are two types of localized Castleman’s disease: the more common hyaline vascular and the plasma cell types. Mixed variant is an uncommon localized lesion in general population. The lesions can occur in any part of the body that contains lymphoid tissue, although seventy percent are found in the anterior mediastinum. We report a thirty years old boy with Castleman’s disease who presented with fever, anorexia, weight loss,sweating, anemia and abdominal mass. The histologic examination of the biopsy specimens revealed a mixed hyaline vascular and plasma cell type of Castleman’s disease.

  20. Cellular cholesterol efflux to plasma from moderately hypercholesterolaemic type 1 diabetic patients is enhanced, and is unaffected by simvastatin treatment

    NARCIS (Netherlands)

    de Vries, R; Kerstens, MN; Sluiter, WJ; Groen, AK; van Tol, A; Dullaart, RPF

    Cellular cholesterol efflux to plasma is important in reverse cholesterol transport and may be affected by simvastatin in type 1 diabetes mellitus. In 14 moderately hypercholesterolaemic type 1 diabetic and 13 healthy men we determined plasma (apo)lipoproteins, pre-beta HDL formation, cholesteryl

  1. Study on the related risk factors with atherogenic index of plasma in male type 2 diabetic patients

    Institute of Scientific and Technical Information of China (English)

    吴晓明

    2012-01-01

    Objective To study related factors with atherogenic index of plasma in male type 2 diabetic patients. Methods 133 male patients with type 2 diabetes mellitus were divided into non-atherogenic phenom (N group) and atherogemic phenom(A group) according to the cutpoint of atherogenic index of plasma

  2. New type X—ray mask fabricated using inductvely coupled plasma deepetching

    Institute of Scientific and Technical Information of China (English)

    D.Chen; W.Lei; S.Wang; C.Li; X.Guo; H.Mao; D.Zhang; F.Yi

    2001-01-01

    The fabrication of X-ray masks is a critical and challenging process in LIGA technique.As inductively coupled plasma(ICP) deepetching appears to be the most suitable source for deep silicon etching,we fabricated a new type X-ray mask using this technique.In comparison with other types of X-ray masks,the mask we fabricated has the advantages of its low cost and its simple fabrication process.Besired microstructures have also been fabricated using this new type X-ray mask in LIGA technique.

  3. A numerical simulation of surface wave excitation in a rectangular planar-type plasma source

    Institute of Scientific and Technical Information of China (English)

    Chen Zhao-Quan; Liu Ming-Hai; Lan Chao-Hui; Chen Wei; Tang Liang; Luo Zhi-Qing; Yan Bao-Rong; Lu Jian-Hong; Hu Xi-Wei

    2009-01-01

    The principle of surface wave plasma discharge in a rectangular cavity is introduced simply based on surface plasmon polariton theory.The distribution of surface-wave electric field at the interface of the plasma-dielectric slab is investigated by using the three-dimensional finite-difference time-domain method (3D-FDTD) with different slotantenna structures.And the experimental image of discharge with a novel slot antenna array and the simulation of the electric field with this slot antenna array are both displayed.Combined with the distribution of surface wave excitation and experimental results,the numerical simulation performed by using 3D-FDTD is shown to be a useful tool in the computer-aided antenna design for large area planar-type surface-wave plasma sources.

  4. Interventions for Learning Disabilities: Does a Journal-Based Change in Focus and Article Type Reflect or Influence Legal Mandates?

    Science.gov (United States)

    McCleary, Daniel F.; Rowlette, Emily Fuller; Pelchar, Taylor K.; Bain, Sherry K.

    2013-01-01

    We investigated whether there was a noticeable shift in focus from general to specific learning disabilities, and in the types of articles (narrative or empirically based) in the Journal of Learning Disabilities (JLD) between 1995 to 2000. A pilot study had revealed an increase in empirically based articles and a shift toward specifically…

  5. Sulfonated polystyrene-type plasma-polymerized membranes for miniature direct methanol fuel cells

    Science.gov (United States)

    Roualdes, Stéphanie; Topala, Ionut; Mahdjoub, Habiba; Rouessac, Vincent; Sistat, Philippe; Durand, Jean

    Sulfonated polystyrene-type membranes were synthesized by plasma polymerization of a mixture of styrene and trifluoromethane sulfonic acid monomers in a low-frequency after-glow discharge plasma reactor. Such a deposition process enables the preservation of the monomers structure, which was confirmed by mass spectrometry analysis. The synthesized plasma-polymerized membranes are dense and uniform with a few microns thickness. Their structure determined by Fourier-transform infra-red spectroscopy and X-ray photoelectron spectroscopy is very rich in sulfonic acid groups (up to 5%) and stable up to 120 °C. Even if their intrinsic proton conductivity is low (10 -1 mS cm -1), directly related to their disorganized and highly cross-linked structure, plasma-polymerized membranes present a proton conduction ability similar to Nafion ® because of their low thickness. Due to their highly cross-linked structure, these membranes enable a reduction of the methanol crossover in a factor 10 by comparison with Nafion ®. Thus, the integration of plasma-polymerized films in miniaturized direct methanol fuel cells as proton-exchange membranes seems promising.

  6. [Insulin pump in type 2 diabetes: B-cell focused treatment].

    Science.gov (United States)

    Picková, Klára; Rušavý, Zdeněk

    2017-01-01

    Type 2 diabetes is a disorder characterized by insulin resistance and progressive deterioration of B-cell insulin secretion. B-cell protective strategies for lowering glucolipotoxicity by rapid achievement of normoglycemia using exogenous insulin improve their function and prolong diabetes remission. Insulin pump is an effective treatment method in newly diagnosed diabetes, where even short-term pump therapy is B-cell protective. Combination therapy with insulin pump and antidiabetics targeting the incretin system acts in synergy to protect the B-cell. While the positive effect of insulin pump is apparent even a year after stopping the therapy, the effect of incretins lasts only while on the medication. Short-term insulin treatment, especially delivered by insulin pump, is an effective method of B-cell protection in recent type 2 diabetes.Key words: B-cell function - diabetes mellitus - insulin pump - insulin resistance - type 2 diabetes.

  7. Diagnosis of type III hyperlipoproteinemia by chromatography of plasma lipoproteins on columns containing agarose.

    Science.gov (United States)

    Shepherd, J; Packard, C J; Dryburgh, F J; Third, J L

    1975-12-01

    Agarose column chromatography has been used to separate plasma lipoproteins into very-low-density lipoproteins (VLDL), low-density lipoproteins (LDL) and high-density lipoproteins (HDL). Applied to the diagnosis of primary type III hyperlipoproteinemia, the procedure is capable of demonstrating three characteristic and specific changes from normality in the elution pattern of lipoproteins from patients with this condition. In the type III profile there is (a) incomplete separation of VLDL from putative LDL material, (b) early elution of the type III LDL with respect to a normal LDL marker, and (c) relative deficiency of type III LDL with elution characteristics of normal LDL. We advocate the use of this method in the diagnosis of type III hyperlipoproteinemia.

  8. Frequent Intratype Neutralization by Plasma Immunoglobulin A Identified in HIV Type 2 Infection

    OpenAIRE

    Özkaya Şahin, Gülşen; Månsson, Fredrik; Palm, Angelica A.; Vincic, Elzbieta; da Silva, Zacarias; Medstrand, Patrik; Norrgren, Hans; Fenyö, Eva Maria; Jansson, Marianne

    2013-01-01

    Human immunodeficiency virus type 2 (HIV-2) is less transmissible and less pathogenic compared to HIV-1 and, when matched for CD4+ T cell count, the plasma viral load in HIV-2-infected individuals is approximately one log lower than in HIV-1-infected individuals. The explanation for these observations is elusive, but differences in virus controlling immunity generated in the two infections may be contributing factors. In the present study, we investigated neutralization by immunoglobulin A (I...

  9. Intense Cherenkov-type terahertz electromagnetic radiation from ultrafast laser-plasma interaction

    Institute of Scientific and Technical Information of China (English)

    Hu Qiang-Lin; Liu Shi-Bing; Li Wei

    2008-01-01

    A Cherenkov-type terahertz electromagnetic radiation is revealed, which results efficiently from the collective effects in the time-domain of ultrafast pulsed electron current produced by ultrafast intense laser-plasma interaction.The emitted pulse waveform and spectrum, and the dependence of laser pulse parameters on the structure of the radiation field are investigated numerically. The condition of THz radiation generation in this regime and Cherenkov geometry of the radiation field are studied analytically.

  10. The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

    Science.gov (United States)

    Cornish, S.; Khachan, J.

    2016-02-01

    A new and simple type of electron gun is presented. Unlike conventional electron guns, which require a heated filament or extractor, accelerator and focusing electrodes, this gun uses the collimated electron microchannels of an inertial electrostatic confinement (IEC) discharge to achieve the same outcome. A cylindrical cathode is placed coaxially within a cylindrical anode to create the discharge. Collimated beams of electrons and fast neutrals emerge along the axis of the cylindrical cathode. This geometry isolates one of the microchannels that emerge in a negatively biased IEC grid. The internal operating pressure range of the gun is 35-190 mTorr. A small aperture separates the gun from the main vacuum chamber in order to achieve a pressure differential. The chamber was operated at pressures of 4-12 mTorr. The measured current produced by the gun was 0.1-3 mA (0.2-14 mA corrected measurement) for discharge currents of 1-45 mA and discharge voltages of 0.5-12 kV. The collimated electron beam emerges from the aperture into the vacuum chamber. The performance of the gun is unaffected by the pressure differential between the vacuum chamber and the gun. This allows the aperture to be removed and the chamber pressure to be equal to the gun pressure if required.

  11. Dense Plasma Focus as Collimated Source of D-D Fusion Neutron Beams for Irradiation Experiences and Study of Emitted Radiations

    Science.gov (United States)

    Milanese, M.; Niedbalski, J.; Moroso, R.; Guichón, S.; Supán, J.

    2008-04-01

    A "table-top" 2 kJ, 250 kA plasma focus, the PACO (Plasma AutoConfinado), designed by the Dense Plasma Group of IFAS is used in its optimum regime for neutron yield for obtaining collimated pulsed neutron beams (100 ns). A simple and low-cost shielding arrangement was developed in order to fully eliminate the 2.45 MeV neutrons generated in the PACO device (108 per shot at 31 kV, 1-2 mbar). Conventional neutron diagnostics: scintillator-photomultiplier (S-PMT), silver activation counters (SAC), etc., are used to determine the minimum width of the shielding walls. Emission of very hard electromagnetic pulses is also studied. Collimation using lead and copper plates is made to determine the localization of the very hard X-ray source. The maximum energy of the continuum photon distribution is estimated in 0,6 MeV using a system of filters.

  12. Plasma Pressure Driven Magnetic Self-Focusing of Aspherical Supernovae and Highly Collimated Gamma-Ray Bursts

    CERN Document Server

    Tsui, K H

    2012-01-01

    During the process of core-collapse of a massive star, the iron core evolves into an inner central core and an outer envelope, generating a cavity in between. The dynamics of this cavity, filled with plasma and magnetic field by the rapidly rotating pulsar (spun-down magnetar) at the center, is believed to be very relevant to account for supernovae and gamma-ray bursts \\citep{uzdensky2007}. The interactions of the pressurized conducting plasma and the magnetic field could generate some spatial distributions of plasma and magnetic field within the cavity. In an effort to better understand the spatial distributions, a set of time-dependent magnetohydrodynamic (MHD) equations is used to model this cavity system. Homologous solutions in Lagrangian representation are obtained to account for the spatial structures. Under this self-similar description, the magnetic flux function is governed by an eigenvalue equation with the eigenvalue being the poloidal plasma $\\beta$, which is the ratio of plasma pressure to poloi...

  13. Frequent intratype neutralization by plasma immunoglobulin a identified in HIV type 2 infection.

    Science.gov (United States)

    Özkaya Şahin, Gülşen; Månsson, Fredrik; Palm, Angelica A; Vincic, Elzbieta; da Silva, Zacarias; Medstrand, Patrik; Norrgren, Hans; Fenyö, Eva Maria; Jansson, Marianne

    2013-03-01

    Human immunodeficiency virus type 2 (HIV-2) is less transmissible and less pathogenic compared to HIV-1 and, when matched for CD4(+) T cell count, the plasma viral load in HIV-2-infected individuals is approximately one log lower than in HIV-1-infected individuals. The explanation for these observations is elusive, but differences in virus controlling immunity generated in the two infections may be contributing factors. In the present study, we investigated neutralization by immunoglobulin A (IgA), in parallel with IgG, purified from plasma of HIV-1, HIV-2, and HIV-1/HIV-2 dually (HIV-D) infected individuals. Neutralization was analyzed against HIV-1 and HIV-2 isolates using a plaque reduction assay. In HIV-2 infection, intratype-specific neutralization by IgA was frequently detected, although at a lesser magnitude then the corresponding IgG neutralizing titers. In contrast, neutralization by IgA could rarely be demonstrated in HIV-1 infection despite similar plasma IgA levels in both infections. In addition, IgA and IgG of HIV-D plasma neutralized the HIV-2 isolate more potently than the HIV-1 isolate, suggesting that the difference between neutralizing activity of plasma IgA and IgG depends on the virus itself. Taken together, these findings suggest that both IgA and IgG add to the potent intratype neutralizing activity detected in HIV-2 plasma, which may contribute to virus control in HIV-2 infection.

  14. Plasma lysophosphatidylcholine levels are reduced in obesity and type 2 diabetes.

    Directory of Open Access Journals (Sweden)

    Melissa N Barber

    Full Text Available BACKGROUND: Obesity and type 2 diabetes (T2DM are associated with increased circulating free fatty acids and triacylglycerols. However, very little is known about specific molecular lipid species associated with these diseases. In order to gain further insight into this, we performed plasma lipidomic analysis in a rodent model of obesity and insulin resistance as well as in lean, obese and obese individuals with T2DM. METHODOLOGY/PRINCIPAL FINDINGS: Lipidomic analysis using liquid chromatography coupled to mass spectrometry revealed marked changes in the plasma of 12 week high fat fed mice. Although a number of triacylglycerol and diacylglycerol species were elevated along with of a number of sphingolipids, a particularly interesting finding was the high fat diet (HFD-induced reduction in lysophosphatidylcholine (LPC levels. As liver, skeletal muscle and adipose tissue play an important role in metabolism, we next determined whether the HFD altered LPCs in these tissues. In contrast to our findings in plasma, only very modest changes in tissue LPCs were noted. To determine when the change in plasma LPCs occurred in response to the HFD, mice were studied after 1, 3 and 6 weeks of HFD. The HFD caused rapid alterations in plasma LPCs with most changes occurring within the first week. Consistent with our rodent model, data from our small human cohort showed a reduction in a number of LPC species in obese and obese individuals with T2DM. Interestingly, no differences were found between the obese otherwise healthy individuals and the obese T2DM patients. CONCLUSION: Irrespective of species, our lipidomic profiling revealed a generalized decrease in circulating LPC species in states of obesity. Moreover, our data indicate that diet and adiposity, rather than insulin resistance or diabetes per se, play an important role in altering the plasma LPC profile.

  15. Association of fasting plasma glucose and serum lipids in Type 2 diabetics

    Directory of Open Access Journals (Sweden)

    S Khadke

    2015-01-01

    Full Text Available Dyslipidemia is a significant morbidity associated with diabetes and cardiovascular disorders. The present study was undertaken to assess the lipid profile of type 2 diabetic and age-gender matched healthy subjects and its association, if any, with fasting plasma glucose. Clinically diagnosed diabetic subjects were recruited for the study. The fasting plasma glucose and lipid profiles were analyzed for 99 diabetic and 101 healthy volunteers. The blood samples were analyzed for fasting plasma glucose, total cholesterol, triglycerides, high density lipoprotein-cholesterol, low density lipoprotein-cholesterol and very low density lipoprotein-cholesterol. Correlation analysis of lipid profile with fasting plasma glucose and calculation of risk ratio was done. The levels of high density lipoprotein-cholesterol and low density lipoprotein-cholesterol were found to be significantly low in diabetics and subjects with lower low density lipoprotein-cholesterol were on statins. Inspite of lower lipid values, the risk ratio for diabetics was significantly higher. The correlation analysis indicated significant difference in relationship between fasting plasma glucose, lipid parameters and risk ratios in the two groups. Diabetics with lower high density lipoprotein-cholesterol and higher total cholesterol present with a higher risk ratio pointing to need of non-statin high density lipoprotein-raising medications decreasing their predisposition to cardiovascular disorders. The study highlights the altered pattern of correlation of lipid profile with fasting plasma glucose in diabetics and their increased risk of cardiovascular disorders. The dyslipidemia in the form of triglyceridemia and significantly low high density lipoprotein-cholesterol in diabetics point towards the need of non-statin high density lipoprotein-raising medications.

  16. Type 2 diabetes associated changes in the plasma non-esterified fatty acids, oxylipins and endocannabinoids.

    Directory of Open Access Journals (Sweden)

    Dmitry Grapov

    Full Text Available Type 2 diabetes has profound effects on metabolism that can be detected in plasma. While increases in circulating non-esterified fatty acids (NEFA are well-described in diabetes, effects on signaling lipids have received little attention. Oxylipins and endocannabinoids are classes of bioactive fatty acid metabolites with many structural members that influence insulin signaling, adipose function and inflammation through autocrine, paracrine and endocrine mechanisms. To link diabetes-associated changes in plasma NEFA and signaling lipids, we quantitatively targeted >150 plasma lipidome components in age- and body mass index-matched, overweight to obese, non-diabetic (n = 12 and type 2 diabetic (n = 43 African-American women. Diabetes related NEFA patterns indicated ∼60% increase in steroyl-CoA desaturase activity and ∼40% decrease in very long chain polyunsaturated fatty acid chain shortening, patterns previously associated with the development of nonalcoholic fatty liver disease. Further, epoxides and ketones of eighteen carbon polyunsaturated fatty acids were elevated >80% in diabetes and strongly correlated with changes in NEFA, consistent with their liberation during adipose lipolysis. Endocannabinoid behavior differed by class with diabetes increasing an array of N-acylethanolamides which were positively correlated with pro-inflammatory 5-lipooxygenase-derived metabolites, while monoacylglycerols were negatively correlated with body mass. These results clearly show that diabetes not only results in an increase in plasma NEFA, but shifts the plasma lipidomic profiles in ways that reflect the biochemical and physiological changes of this pathological state which are independent of obesity associated changes.

  17. Type 2 diabetes associated changes in the plasma non-esterified fatty acids, oxylipins and endocannabinoids.

    Science.gov (United States)

    Grapov, Dmitry; Adams, Sean H; Pedersen, Theresa L; Garvey, W Timothy; Newman, John W

    2012-01-01

    Type 2 diabetes has profound effects on metabolism that can be detected in plasma. While increases in circulating non-esterified fatty acids (NEFA) are well-described in diabetes, effects on signaling lipids have received little attention. Oxylipins and endocannabinoids are classes of bioactive fatty acid metabolites with many structural members that influence insulin signaling, adipose function and inflammation through autocrine, paracrine and endocrine mechanisms. To link diabetes-associated changes in plasma NEFA and signaling lipids, we quantitatively targeted >150 plasma lipidome components in age- and body mass index-matched, overweight to obese, non-diabetic (n = 12) and type 2 diabetic (n = 43) African-American women. Diabetes related NEFA patterns indicated ∼60% increase in steroyl-CoA desaturase activity and ∼40% decrease in very long chain polyunsaturated fatty acid chain shortening, patterns previously associated with the development of nonalcoholic fatty liver disease. Further, epoxides and ketones of eighteen carbon polyunsaturated fatty acids were elevated >80% in diabetes and strongly correlated with changes in NEFA, consistent with their liberation during adipose lipolysis. Endocannabinoid behavior differed by class with diabetes increasing an array of N-acylethanolamides which were positively correlated with pro-inflammatory 5-lipooxygenase-derived metabolites, while monoacylglycerols were negatively correlated with body mass. These results clearly show that diabetes not only results in an increase in plasma NEFA, but shifts the plasma lipidomic profiles in ways that reflect the biochemical and physiological changes of this pathological state which are independent of obesity associated changes.

  18. Metabolic syndrome and type 2 diabetes mellitus: focus on peroxisome proliferator activated receptors (PPAR

    Directory of Open Access Journals (Sweden)

    Fisman Enrique Z

    2003-03-01

    Full Text Available Abstract The metabolic syndrome is a highly prevalent clinical entity. The recent Adult Treatment Panel (ATP III guidelines have called specific attention to the importance of targeting the cardiovascular risk factors of the metabolic syndrome as a method of risk reduction therapy. The main factors characteristic of this syndrome are abdominal obesity, atherogenic dyslipidemia, elevated blood pressure, insulin resistance (with or without glucose intolerance, prothrombotic and proinflammatory states. An insulin resistance following nuclear peroxisome proliferator activated receptors (PPAR deactivation (mainly obesity-related is the key phase of metabolic syndrome initiation. Afterwards, there are 2 principal pathways of metabolic syndrome development: 1 with preserved pancreatic beta cells function and insulin hypersecretion which can compensate for insulin resistance. This pathway leads mainly to the macrovascular complications of metabolic syndrome; 2 with massive damage of pancreatic beta cells leading to progressively decrease of insulin secretion and to hyperglycemia (e.g. overt type 2 diabetes. This pathway leads to both microvascular and macrovascular complications. We suggest that a PPAR-based appraisal of metabolic syndrome and type 2 diabetes may improve our understanding of these diseases and set a basis for a comprehensive approach in their treatment.

  19. Sun protection attitudes and behaviours among first generation Australians with darker skin types: results from focus groups.

    Science.gov (United States)

    Bryant, Jamie; Zucca, Alison; Brozek, Irena; Rock, Vanessa; Bonevski, Billie

    2015-02-01

    Despite residing in a country that has the highest rates of skin cancer in the world, little is known about the knowledge, attitudes and sun protection practices of first generation Australian-born individuals with olive and darker skin types. Six focus groups with first generation Australian-born individuals of Asian, Mediterranean, Middle Eastern and Indian background were conducted. Participants had good knowledge of the dangers of skin cancer. Most correctly perceived darker skin types as protective and believed they were at low risk of skin cancer. Most participants could recall high profile mass media sun protection campaigns. Several participants suggested that greater representation of ethnic minorities and/or individuals with darker skin types would increase the personal relevance of campaigns. Beliefs that sun protection is not necessary on the basis of skin type highlights the need for further studies to explore fundamental differences in attitudes and practices between those with olive and darker skin and the general Australian population.

  20. A 160 kJ dual plasma focus (DuPF) for fusion-relevant materials testing and nano-materials fabrication

    Science.gov (United States)

    Saw, S. H.; Damideh, V.; Chong, P. L.; Lee, P.; Rawat, R. S.; Lee, S.

    2014-08-01

    This paper summarizes PF-160 Dual Plasma Focus (DuPF) numerical experiments using the Lee Model code and preliminary 3D design drawings using SolidWorks software. This DuPF consists of two interchangeable electrodes enabling it to be optimized for both Slow Pinch Mode (SFM) and Fast Pinch Mode (FFM); the latter using a speed factor (SF) of 90 kA cm-1 Torr-0.5 for FFM in deuterium [S Lee et al, IEEE Trans Plasma Science 24, 1101-1105 (1996)]; and the former with SF of less than half that value for SFM. Starting with available 6 × 450 µF capacitors rated at 11kV (10% reversal), numerical experiments indicate safe operation at 9 kV, 6 Torr deuterium with FFM anode of 5 cm radius; producing intense ion beam and streaming plasma pulses which would be useful for studies of potential fusion reactor wall materials. On the other hand operating at 5 kV, 10 Torr deuterium with SFM anode of 10 cm radius leads to long-duration, uniform large-area flow which could be more suitable for synthesis of nano-materials. The dual plasma focus design is illustrated here with two figures showing FFM and SFM electrodes.

  1. The electromagnetic Ram action of the plasma focus as a paradigm for the generation of cosmic rays and the gigantic jets in active galaxies

    Science.gov (United States)

    Bostick, W. H.; Nardi, V.

    1985-08-01

    Recent measurements of the energy spectrum of the plasma-focus-generated deuteron beam yield as spectrum of the form N(E)=(approx.) E to the -2.7 for 1MeV E 13 MeV. Other measurements show that the beta 1 electron beam which is generated simultaneously with the deuteron beam is interrupted into segments of spacing 25ps and duration approximately 4ps. A stuttering-electro-magnetic-ram (ser) model of the plasma focus in proposed which is similar to Raudorf's electronic ram which produces a similar spectrum for an electron beam for 1Mev E 10MeV. It is proposed that the cosmic ray spectrum and the giganic galactic jets are both generated by ser action near the centers of active galaxies.

  2. The electromagnetic ram action of the plasma focus as a paradigm for the generation of cosmic rays and the gigantic jets in active galaxies

    Science.gov (United States)

    Bostick, W. H.; Nardi, V.

    1985-01-01

    Recent measurements of the energy spectrum of the plasma-focus-generated deuteron beam yield as spectrum of the form N(E)=(approx.) E to the -2.7 for 1MeV E 13 MeV. Other measurements show that the beta 1 electron beam which is generated simultaneously with the deuteron beam is interrupted into segments of spacing 25ps and duration approximately 4ps. A stuttering-electro-magnetic-ram (ser) model of the plasma focus in proposed which is similar to Raudorf's electronic ram which produces a similar spectrum for an electron beam for 1Mev E 10MeV. It is proposed that the cosmic ray spectrum and the giganic galactic jets are both generated by ser action near the centers of active galaxies.

  3. Time delay in thin slabs with self-focusing Kerr-type nonlinearity

    Science.gov (United States)

    Isić, G.; Milanović, V.; Radovanović, J.; Ikonić, Z.; Indjin, D.; Harrison, P.

    2008-03-01

    Time delays for an intense transverse electric (TE) wave propagating through a Kerr-type nonlinear slab are investigated. The relation between the bidirectional group delay and the dwell time is derived and it is shown that the difference between them can be separated into three terms. The first one is the familiar self-interference time, due to the dispersion of the medium surrounding the slab. The other two terms are caused by the nonlinearity and oblique incidence of the TE wave. It is shown that the electric field distribution along the slab may be expressed in terms of Jacobi elliptic functions while the phase difference introduced by the slab is given in terms of incomplete elliptic integrals. The expressions for the field-intensity-dependent complex reflection and transmission coefficients are derived and the multivalued oscillatory behavior of the delay times for the case of a thin slab is demonstrated.

  4. Improving the energy-extraction efficiency of laser-plasma accelerator driven free-electron laser using transverse-gradient undulator with focusing optics and longitudinal tapering

    CERN Document Server

    Zhou, G; Wu, J; Zhang, T

    2016-01-01

    It is reported that [Z. Huang et al., Phys. Rev. Lett. 109, 204801 (2012)], high-gain free-electron laser (FEL) can be generated by transverse-dispersed electron beams from laser-plasma accelerators (LPAs) using transverse-gradient undulator (TGU) assuming an ideal constant dispersion function without focusing optics. The constant dispersion function keeps electrons beyond the resonant energy bandwidth still being on resonant with the FEL radiation. Instead, in this paper, the case with focusing optics in an LPA-driven FEL using TGU is numerically studied, in which the dispersion function should be monotonously decreasing along the undulator. Even though the FEL resonance is not always satisfied for off-energy electrons in this case, through subtly optimizing the initial dispersion and focusing parameters, it is feasible to achieve a similar radiation power to the case assuming an ideal constant dispersion function without focusing optics, and meanwhile, to attain a good transverse coherence. Moreover, higher...

  5. Evidence of nuclear fusion neutrons in an extremely small plasma focus device operating at 0.1 Joules

    Science.gov (United States)

    Soto, Leopoldo; Pavéz, Cristián; Moreno, José; Altamirano, Luis; Huerta, Luis; Barbaglia, Mario; Clausse, Alejandro; Mayer, Roberto E.

    2017-08-01

    We report on D-D fusion neutron emission in a plasma device with an energy input of only 0.1 J, within a range where fusion events have been considered very improbable. The results presented here are the consequence of scaling rules we have derived, thus being the key point to assure the same energy density plasma in smaller devices than in large machines. The Nanofocus (NF)—our device—was designed and constructed at the P4 Lab of the Chilean Nuclear Energy Commission. Two sets of independent measurements, with different instrumentation, were made at two laboratories, in Chile and Argentina. The neutron events observed are 20σ greater than the background. The NF plasma is produced from a pulsed electrical discharge using a submillimetric anode, in a deuterium atmosphere, showing empirically that it is, in fact, possible to heat and compress the plasma. The strong evidence presented here stretches the limits beyond what was expected. A thorough understanding of this could possibly tell us where the theoretical limits actually lie, beyond conjectures. Notwithstanding, a window is thus open for low cost endeavours for basic fusion research. In addition, the development of small, portable, safe nonradioactive neutron sources becomes a feasible issue.

  6. Plasma calprotectin and its association with cardiovascular disease manifestations, obesity and the metabolic syndrome in type 2 diabetes mellitus patients

    DEFF Research Database (Denmark)

    Pedersen, Lise; Nybo, M.; Poulsen, M. K.

    2014-01-01

    Background: Plasma calprotectin is a potential biomarker of cardiovascular disease (CVD), insulin resistance (IR), and obesity. We examined the relationship between plasma calprotectin concentrations, CVD manifestations and the metabolic syndrome (MetS) in patients with type 2 diabetes mellitus (T2...... associated with obesity, MetS status, autonomic neuropathy, PAD, and MI. However, plasma calprotectin was not an independent predictor of CVD, MI, autonomic neuropathy or PAD....

  7. Focus on migrants with type 2 diabetes mellitus in European Countries.

    Science.gov (United States)

    Testa, Roberto; Bonfigli, Anna Rita; Genovese, Stefano; Ceriello, Antonio

    2016-04-01

    The prevalence of type 2 diabetes mellitus, one of the major causes of morbility and mortality in Europe, is increasing in all European countries. Diabetes is not distributed equally among all population groups, as higher incidence, appearance of complications, and different mortality rates have been observed among migrants and the native population. These differences may be due to genetic profiles, lifestyle, and utilization of the health care system in different ways. Taking into account that the quantity of migrants is nowadays increasing, mainly in the southern part of Europe, the knowledge of diabetes in migrants through a better collection of data is necessary, considering that few limited epidemiological studies have evaluated the importance of this problem in EU countries. A special effort in developing a comprehensive management for native and immigrant populations in order to prevent and cure diabetes should be mandatory. This activity could be helpful to limit the incidence of future diabetes complications and to avoid the consequent burden of the health care system along with a control on its costs. It is clear that diabetes complication prevention is essential for long-term sustainability of the health care system.

  8. β-cell replacement sources for type 1 diabetes: a focus on pancreatic ductal cells.

    Science.gov (United States)

    Corritore, Elisa; Lee, Yong-Syu; Sokal, Etienne M; Lysy, Philippe A

    2016-08-01

    Thorough research on the capacity of human islet transplantation to cure type 1 diabetes led to the achievement of 3- to 5-year-long insulin independence in nearly half of transplanted patients. Yet, translation of this technique to clinical routine is limited by organ shortage and the need for long-term immunosuppression, restricting its use to adults with unstable disease. The production of new bona fide β cells in vitro was thus investigated and finally achieved with human pluripotent stem cells (PSCs). Besides ethical concerns about the use of human embryos, studies are now evaluating the possibility of circumventing the spontaneous tumor formation associated with transplantation of PSCs. These issues fueled the search for cell candidates for β-cell engineering with safe profiles for clinical translation. In vivo studies revealed the regeneration capacity of the exocrine pancreas after injury that depends at least partially on facultative progenitors in the ductal compartment. These stimulated subpopulations of pancreatic ductal cells (PDCs) underwent β-cell transdifferentiation through reactivation of embryonic signaling pathways. In vitro models for expansion and differentiation of purified PDCs toward insulin-producing cells were described using cocktails of growth factors, extracellular-matrix proteins and transcription factor overexpression. In this review, we will describe the latest findings in pancreatic β-cell mass regeneration due to adult ductal progenitor cells. We will further describe recent advances in human PDC transdifferentiation to insulin-producing cells with potential for clinical translational studies.

  9. Wind mass transfer in S-type symbiotic binaries II. Indication of wind focusing

    CERN Document Server

    Shagatova, Natalia; Carikova, Zuzana

    2016-01-01

    Context. The wind mass transfer from a giant to its white dwarf companion in symbiotic binaries is not well understood. For example, the efficiency of wind mass transfer of the canonical Bondi-Hoyle accretion mechanism is too low to power the typical luminosities of the accretors. However, recent observations and modelling indicate a considerably more efficient mass transfer in symbiotic binaries. Aims. We determine the velocity profile of the wind from the giant at the near-orbital-plane region of eclipsing S-type symbiotic binaries EG And and SY Mus, and derive the corresponding spherical equivalent of the mass-loss rate. With this approach, we indicate the high mass transfer ratio. Methods. We achieved this aim by modelling the observed column densities taking into account ionization of the wind of the giant, whose velocity profile is derived using the inversion of Abel's integral operator for the hydrogen column density function. Results. Our analysis revealed the spherical equivalent of the mass-loss rat...

  10. Impact of hemoglobin on plasma pro-B-type natriuretic peptide concentrations in the general population

    DEFF Research Database (Denmark)

    Nybo, Mads; Benn, Marianne; Mogelvang, Rasmus

    2007-01-01

    BACKGROUND: Age, sex, and renal function contribute to variations in plasma concentrations of B-type natriuretic peptide (BNP) and its molecular precursor (proBNP). Recent studies indicate that anemia may also affect proBNP concentrations in patients with heart failure or stroke. However...... the proBNP plasma concentration. RESULTS: The mean proBNP concentration was increased 1.7-fold in the group with anemia vs the nonanemic group [mean (SD) 42 (45) pmol/L vs 25 (29) pmol/L, P ... was modest. CONCLUSIONS: Because moderate anemia is associated with a 1.7-fold increase in proBNP concentrations, hemoglobin concentrations should be taken into consideration in patients with nonspecific symptoms of heart disease and increased proBNP concentrations....

  11. Plasma copeptin as marker of cardiovascular disease in asymptomatic type 2 diabetes patients

    DEFF Research Database (Denmark)

    Bar-Shalom, Dana; Poulsen, Mikael K; Rasmussen, Lars M;

    2014-01-01

    for sub-clinical CVD. A total of 302 T2DM patients referred to the Diabetes Clinic at Odense University Hospital, Denmark, entered the study. None of the patients had known or suspected CVD. As a control group, 30 healthy adults were recruited from the DanRisk study - a random sample of middle-aged Danes....... A variety of clinical investigations were performed, including blood pressure measurements, carotid intima media thickness evaluation and myocardial perfusion scintigraphy. Blood sample analyses included copeptin measurements. Median plasma copeptin concentrations were similar in the T2DM group......Recently, copeptin was found associated with cardiovascular disease (CVD) and all-cause mortality in type 2 diabetes mellitus (T2DM) patients treated in primary care. This study aimed to evaluate whether plasma copeptin correlated to CVD in asymptomatic T2DM patients intensively investigated...

  12. Weight reduction and the impaired plasma-derived free fatty acid oxidation in type 2 diabetic subjects

    NARCIS (Netherlands)

    Blaak, EE; Wolffenbuttel, BHR; Saris, WHM; Pelsers, MMAL; Wagenmakers, AJM

    2001-01-01

    In a previous study the oxidation of plasma free fatty acids (FFA) under baseline conditions and during exercise was lower in type 2 diabetic subjects compared with weight-matched controls. The present study intended to investigate the effect of weight reduction (very low calorie diet) on plasma FFA

  13. Weight reduction and the impaired plasma-derived free fatty acid oxidation in type 2 diabetic subjects

    NARCIS (Netherlands)

    Blaak, EE; Wolffenbuttel, BHR; Saris, WHM; Pelsers, MMAL; Wagenmakers, AJM

    2001-01-01

    In a previous study the oxidation of plasma free fatty acids (FFA) under baseline conditions and during exercise was lower in type 2 diabetic subjects compared with weight-matched controls. The present study intended to investigate the effect of weight reduction (very low calorie diet) on plasma FFA

  14. Sustained high plasma mannose less sensitive to fluctuating blood glucose in glycogen storage disease type Ia children

    NARCIS (Netherlands)

    Nagasaka, Hironori; Yorifuji, Tohru; Bandsma, Robert H. J.; Takatani, Tomozumi; Asano, Hisaki; Mochizuki, Hiroshi; Takuwa, Mayuko; Tsukahara, Hirokazu; Inui, Ayano; Tsunoda, Tomoyuki; Komatsu, Haruki; Hiejima, Eitaro; Fujisawa, Tomoo; Hirano, Ken-ichi; Miida, Takashi; Ohtake, Akira; Taguchi, Tadao; Miwa, Ichitomo

    2013-01-01

    Plasma mannose is suggested to be largely generated from liver glycogen-oriented glucose-6-phosphate. This study examined plasma mannose in glycogen storage disease type Ia (GSD Ia) lacking conversion of glucose-6-phosphate to glucose in the liver. We initially examined fasting-and postprandial 2 h-

  15. 2D hydrodynamic simulation of a line-focused plasma in Ni-like Ag x-ray laser research

    Institute of Scientific and Technical Information of China (English)

    Zheng Wu-Di; Zhang Guo-Ping

    2007-01-01

    In most collisional schemes of x-ray laser (XRL) experiments, a bow-like intensity distribution of XRL is often observed, and it is generally ascribed to the two-dimensional hydrodynamic behaviour of expanding plasma. In order to better understand its essence in physics, a newly developed two-dimensional non-equilibrium radiation hydrodynamic code XRL2D is used to simulate a quasi-steady state Ni-like Ag XRL experiment on ShenGuang-II facility. The simulation results show that the bow-like distribution of Ni-like ions caused by over-ionization in the central area of plasma is responsible for the bow-like shape of the XRL intensity distribution observed.

  16. Higher Plasma Methylglyoxal Levels are Associated with Incident Cardiovascular Disease in Individuals with Type 1 Diabetes

    DEFF Research Database (Denmark)

    Hanssen, Nordin M J; Scheijen, Jean L J M; Jorsal, Anders

    2017-01-01

    Methylglyoxal (MGO), a major precursor for advanced glycation endproducts (AGEs), is increased in diabetes. In diabetic rodents, inhibition of MGO prevents cardiovascular disease (CVD). Whether plasma MGO levels are associated with incident CVD in people with type 1 diabetes is unknown. We included...... analyzed with Cox regression, with adjustment for sex, age, HbA1c, DN, diabetes duration, smoking, systolic blood pressure, anti-hypertensive medication and BMI. During follow-up, 73 individuals suffered at least one CVD event (36 fatal and 53 non-fatal events). Higher MGO levels were associated with total...... events in individuals with type 1 diabetes. MGO may explain the increased risk, at least in part, for CVD in type 1 diabetes....

  17. Enhancement of H{sup -}/D{sup -} volume production in a double plasma type negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fukumasa, Osamu; Nishimura, Hideki; Sakiyama, Satoshi [Yamaguchi Univ., Ube (Japan). Faculty of Engineering

    1997-02-01

    H{sup -}/D{sup -} production in a pure volume source has been studied. In our double plasma type negative ion source, both energy and density of fast electrons are well controlled. With the use of this source, the enhancement of H{sup -}/D{sup -} production has been observed. Namely, under the same discharge power, the extracted H{sup -}/D{sup -} current in the double plasma operation is higher than that in the single plasma operation. At the same time, measurements of plasma parameters have been made in the source and the extractor regions for these two cases. (author)

  18. Comparative biochemical studies of fresh frozen plasma and pooled solvent/detergent-treated plasma (octaplasLG(®) ) with focus on protein S and its impact in different thrombin generation assay set-ups.

    Science.gov (United States)

    Heger, A; Janisch, S; Pock, K; Römisch, J

    2016-10-01

    The solvent/detergent treatment enables effective and robust inactivation of all lipid-enveloped viruses, but also inactivates partly sensitive plasma proteins such as protein S. The aim of this study was to investigate the thrombin generation capacity of octaplasLG(®) , in particular focusing on the function of protein S in thrombin generation assay and the impact of assay settings. Sixteen octaplasLG(®) batches and 32 units of single donor fresh frozen plasma (FFP) were investigated. For protein S, both functional activity and free antigen levels were measured. Thrombin generation assay was performed using two fluorogenic tests with different triggers. Finally, rotational thromboelastometry was performed. Mean protein S levels were lower in octaplasLG(®) , but a wider range of values was found for FFP. Clotting parameters and thrombin generation capacities overlapped between the two plasma groups as demonstrated using both thrombin generation assays and different triggers. Spiking studies with protein S-depleted plasma, human purified protein S or antibodies against protein S confirmed a correlation between protein S and thrombin generation capacity under specific assay conditions, especially in an assay with low tissue factor concentration. Correlation between protein S and thrombin generation capacity was demonstrated in the TGA. Due to higher variability in protein S content in the FFP group, overlapping haemostatic potentials of the two plasma groups were found. © 2016 International Society of Blood Transfusion.

  19. Plasma properties of a new-type surface wave-sustained plasma source under the conditions of depositing DLC films

    Science.gov (United States)

    Xu, Junqi; Kousaka, Hiroyuki; Umehara, Noritsugu; Diao, Dongfeng

    2006-01-01

    Surface wave-sustained plasma (SWP) is one of the low-pressure, high- density plasma. Applying this technique, diamond-like carbon (DLC) films with excellent characteristics can be prepared by physical vapor deposition (PVD) method. However, the films' application is restricted in some degree, because it is difficult to control the film properties. In this paper, SWP was excited along a conductive rod at a frequency of 2.45 GHz without magnetic fields around the chamber wall. The fundamental theories of plasma diagnostic were presented and plasma properties were studied with a Langmuir probe under the conditions of depositing DLC films by PVD method with a graphite target. Plasma density, electron temperature, plasma potential and target current were measured at difference technique parameters such as gas pressure, microwave power, and so on. As a result, it was proved that plasma properties are greatly affected by microwave power, target voltage and argon gas pressure in chamber. The gas mass flow rate had almost no effect on plasma characters. At the same time, the results indicated that electron density is up to 10 11-10 12cm -3 even at the low pressure of 1 Pa.

  20. Reliable test for prenatal prediction of fetal RhD type using maternal plasma from RhD negative women

    DEFF Research Database (Denmark)

    Clausen, Frederik Banch; Krog, Grethe Risum; Rieneck, Klaus;

    2005-01-01

    The objective of this study was to establish a reliable test for prenatal prediction of fetal RhD type using maternal plasma from RhD negative women. This test is needed for future prenatal Rh prophylaxis.......The objective of this study was to establish a reliable test for prenatal prediction of fetal RhD type using maternal plasma from RhD negative women. This test is needed for future prenatal Rh prophylaxis....

  1. Plasma NT-proBNP and White Matter Hyperintensities in Type 2 Diabetic Patients

    DEFF Research Database (Denmark)

    Reinhard, Henrik; Garde, Ellen; Skimminge, Arnold

    2012-01-01

    Elevated plasma N-terminal (NT)-proBNP from the heart as well as white matter hyperintensities (WMH) in the brain predict cardiovascular (CV) mortality in the general population. The cause of poor prognosis associated with elevated P-NT-proBNP is not known but WMH precede strokes in high risk...... populations. We assessed the association between P-NT-proBNP and WMH or brain atrophy measured with magnetic resonance imaging (MRI) in type 2 diabetic patients, and age-matched controls....

  2. Plasma NT-proBNP and White Matter Hyperintensities in Type 2 Diabetic Patients

    DEFF Research Database (Denmark)

    Reinhard, Henrik; Garde, Ellen; Skimminge, Arnold;

    2012-01-01

    Elevated plasma N-terminal (NT)-proBNP from the heart as well as white matter hyperintensities (WMH) in the brain predict cardiovascular (CV) mortality in the general population. The cause of poor prognosis associated with elevated P-NT-proBNP is not known but WMH precede strokes in high risk pop...... populations. We assessed the association between P-NT-proBNP and WMH or brain atrophy measured with magnetic resonance imaging (MRI) in type 2 diabetic patients, and age-matched controls....

  3. Synthesis of nonstoichiometric M-type barium ferrite nanobelt by spark plasma sintering method

    Institute of Scientific and Technical Information of China (English)

    ZHAO Wenyu; ZHANG Qingjie; TANG Xinfeng; CHENG Haibin

    2005-01-01

    This study investigated the feasibility of ultrafast crystallization of M-type barium ferrite when the coprecipitation precursors in stoichiometric proportions as BaFe12O19, Fe(OH)3 and BaCO3 nanoparticles, had been heated by spark plasma sintering (SPS) process. The results show that SPS method may realize the ultrafast crystallization of M-type barium ferrite, absolutely prevent the crystallization of intermediate phase α-Fe2O3, and significantly decrease the crystallization temperature of M-type barium ferrite. The sintered samples obtained at 800℃ by sintering the precursors for 10 minutes are a kind of multiphase ferrites composed of major phase M-type barium ferrite and trace amount of BaFe0.24Fe0.76O2.88. It is discovered that M-type barium ferrites in the holes of the sintered samples are in nanobelt microstructure about 100-300 nm in width and several micrometers in length. These M-type barium ferrite nanobelts are non-stoichiometric and may be expressed as BaFe12+Xo19+1.5x (-4.77≤x≤6.50). Their composistions suggest completely random Fe-rich or Ba-rich domains.

  4. ASSOCIATION OF VITAMIN D LEVEL WITH FASTING PLASMA GLUCOSE IN TYPE 2 DIABETIC PATIENTS

    Directory of Open Access Journals (Sweden)

    Josephine Latha

    2015-09-01

    Full Text Available BACKGROUND : The prevalence of vitamin D deficiency has increased in India. Recently there have been plenty of research studies pointing to the essentiality of vitamin D beyond bone health. Type 2 diabetes is also found to be more prevalent in individuals with hypovita minosis D. AIM: To evaluate the levels of vitamin D in type 2 diabetic patients and age matched healthy controls in South Indian population and also to correlate vitamin D level with fasting plasma glucose level and lipid profile in type 2 diabetic patient s. MATERIALS AND METHODS: This cross - sectional study include d 51 type2 diabetic patients and 51 healthy controls. Estimation of Fasting blood glucose and lipid profile was done in Beckmann - Coulter auto analyzer using standard kits. Vitamin D was estimated by Chemiluminescent Immuno Assay (C.L.I.A. Statistical analysis was done using SPSS version 21 software. RESULTS: The vitamin D level was significantly lower in the diabetic patients. The fasting plasma glucose, total cholesterol, triglycerides, low densi ty lipoproteins and very low density lipoproteins were increased in patients with vitamin D deficiency (i.e. vitamin D < 20 ng/ml but the increase was statistically significant only in fasting blood glucose and triglycerides(p<0.01. The level of high den sity lipoproteins was statistically significantly lower in the vitamin D deficient group (p<0.01. By Pearson’s correlation vitamin D was found to be negatively correlated significantly (p value < 0.01 with fasting blood sugar and triglycerides and was fo und to be positively correlated significantly (p value <0.01 with HDL. CONCLUSION: There is high prevalence of Vitamin D deficiency in type 2 diabetic patients. These individuals have also been proved to have atherogenic dyslipidemia that may lead to vasc ular complications. Whether supplementing diabetic patients with vitamin D helps in reducing further complications is yet to be proved by interventional studies.

  5. Plasma apolipoprotein C-III levels, triglycerides, and coronary artery calcification in type 2 diabetics.

    Science.gov (United States)

    Qamar, Arman; Khetarpal, Sumeet A; Khera, Amit V; Qasim, Atif; Rader, Daniel J; Reilly, Muredach P

    2015-08-01

    Triglyceride-rich lipoproteins have emerged as causal risk factors for developing coronary heart disease independent of low-density lipoprotein cholesterol levels. Apolipoprotein C-III (ApoC-III) modulates triglyceride-rich lipoprotein metabolism through inhibition of lipoprotein lipase and hepatic uptake of triglyceride-rich lipoproteins. Mutations causing loss-of-function of ApoC-III lower triglycerides and reduce coronary heart disease risk, suggestive of a causal role for ApoC-III. Little data exist about the relationship of ApoC-III, triglycerides, and atherosclerosis in patients with type 2 diabetes mellitus (T2DM). Here, we examined the relationships between plasma ApoC-III, triglycerides, and coronary artery calcification in patients with T2DM. Plasma ApoC-III levels were measured in a cross-sectional study of 1422 subjects with T2DM but without clinically manifest coronary heart disease. ApoC-III levels were positively associated with total cholesterol (Spearman r=0.36), triglycerides (r=0.59), low-density lipoprotein cholesterol (r=0.16), fasting glucose (r=0.16), and glycosylated hemoglobin (r=0.12; Ptriglycerides (Tobit regression ratio, 1.43; 95% confidence interval, 0.94-2.18; P=0.086) and separately for very low-density lipoprotein cholesterol (Tobit regression ratio, 1.14; 95% confidence interval, 0.75-1.71; P=0.53). In persons with T2DM, increased plasma ApoC-III is associated with higher triglycerides, less favorable cardiometabolic phenotypes, and higher coronary artery calcification, a measure of subclinical atherosclerosis. Therapeutic inhibition of ApoC-III may thus be a novel strategy for reducing plasma triglyceride-rich lipoproteins and cardiovascular risk in T2DM. © 2015 American Heart Association, Inc.

  6. Neon soft x-ray emission studies from the UNU-ICTP plasma focus operated with longer than optimal anode length

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadi, M A [Faculty of Physics, University of Tabriz, Tabriz, Iran (Iran, Islamic Republic of); Verma, R [Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University (Singapore); Sobhanian, S [Faculty of Physics, University of Tabriz, Tabriz, Iran (Iran, Islamic Republic of); Wong, C S [Plasma Research Laboratory, Physics Department, University of Malaya, Kuala Lumpur (Malaysia); Lee, S [Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University (Singapore); Springham, S V [Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University (Singapore); Tan, T L [Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University (Singapore); Lee, P [Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University (Singapore); Rawat, R S [Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University (Singapore)

    2007-11-15

    The UNU-ICTP plasma focus with a significantly longer than conventional anode can still be a reasonably good neon soft x-ray (SXR) source. The highest average neon SXR yield of 3.3 J was achieved at 3 mbar. The time difference between the two first peaks of the voltage probe signal at the radial collapse phase was found to be inversely related to the SXR yield, i.e. the smaller the time difference, the higher the yield and vice versa. The estimation of average current sheath speeds using the shadowgraphic method coupled with laser and focus peak timing signals showed that the average axial rundown speed is similar to the one obtained for the optimal anode length but the average radial compression speed is decreased significantly. The range of pressure for a good neon SXR yield, however, has become much narrower, making efficient plasma focus operation a very sensitive function of the filling gas pressure for longer than the optimal anode length.

  7. Re-appraisal and extension of the Gratton-Vargas two-dimensional analytical snowplow model of plasma focus. II. Looking at the singularity

    Energy Technology Data Exchange (ETDEWEB)

    Auluck, S. K. H., E-mail: skhauluck@gmail.com [HiQ TechKnowWorks Private Limited, Nerul, Navi Mumbai 400706 (India)

    2015-11-15

    The Gratton-Vargas snowplow model, recently revisited and expanded [S. K. H. Auluck, Phys. Plasmas 20, 112501 (2013)], has given rise to significant new insights into some aspects of the Dense Plasma Focus (DPF), in spite of being a purely kinematic description having no reference to plasma phenomena. It is able to provide a good fit to the experimental current waveforms in at least 4 large facilities. It has been used for construction of a local curvilinear frame of reference, in which conservation laws for mass, momentum, and energy can be reduced to effectively-one-dimensional hyperbolic conservation law equations. Its utility in global parameter optimization of device parameters has been demonstrated. These features suggest that the Gratton-Vargas model deserves a closer look at its supposed limitations near the singular phase of the DPF. This paper presents a discussion of its development near the device axis, based on the original work of Gratton and Vargas, with some differences. It is shown that the Gratton-Vargas partial differential equation has solutions for times after the current singularity, which exhibit an expanding bounded volume (which can serve as model of an expanding plasma column) and decreasing dynamic inductance of the discharge, in spite of having no built-in hydrodynamics. This enables the model to qualitatively reproduce the characteristic shape of the current derivative in DPF experiments without reference to any plasma phenomena, such as instabilities, anomalous resistance, or reflection of hydrodynamic shock wave from the axis. The axial propagation of the solution exhibits a power-law dependence on the dimensionless time starting from the time of singularity, which is similar to the power-law relations predicted by theory of point explosions in ideal gases and which has also been observed experimentally.

  8. Re-appraisal and extension of the Gratton-Vargas two-dimensional analytical snowplow model of plasma focus. II. Looking at the singularity

    Science.gov (United States)

    Auluck, S. K. H.

    2015-11-01

    The Gratton-Vargas snowplow model, recently revisited and expanded [S. K. H. Auluck, Phys. Plasmas 20, 112501 (2013)], has given rise to significant new insights into some aspects of the Dense Plasma Focus (DPF), in spite of being a purely kinematic description having no reference to plasma phenomena. It is able to provide a good fit to the experimental current waveforms in at least 4 large facilities. It has been used for construction of a local curvilinear frame of reference, in which conservation laws for mass, momentum, and energy can be reduced to effectively-one-dimensional hyperbolic conservation law equations. Its utility in global parameter optimization of device parameters has been demonstrated. These features suggest that the Gratton-Vargas model deserves a closer look at its supposed limitations near the singular phase of the DPF. This paper presents a discussion of its development near the device axis, based on the original work of Gratton and Vargas, with some differences. It is shown that the Gratton-Vargas partial differential equation has solutions for times after the current singularity, which exhibit an expanding bounded volume (which can serve as model of an expanding plasma column) and decreasing dynamic inductance of the discharge, in spite of having no built-in hydrodynamics. This enables the model to qualitatively reproduce the characteristic shape of the current derivative in DPF experiments without reference to any plasma phenomena, such as instabilities, anomalous resistance, or reflection of hydrodynamic shock wave from the axis. The axial propagation of the solution exhibits a power-law dependence on the dimensionless time starting from the time of singularity, which is similar to the power-law relations predicted by theory of point explosions in ideal gases and which has also been observed experimentally.

  9. Plasma adrenaline kinetics in type 1 (insulin-dependent) diabetic patients with and without autonomic neuropathy

    DEFF Research Database (Denmark)

    Dejgaard, A; Hilsted, J; Henriksen, Jens Henrik Sahl

    1989-01-01

    labelled adrenaline had been stopped was significantly prolonged in Type 1 diabetic patients with neuropathy compared to those without (after 20 min infusion 2.7 vs 2.2 min, p less than 0.02, after 75 min infusion 3.7 vs 2.9 min, p less than 0.05). The corresponding values for the mean sojourn time...... volume in Type 1 diabetic patients with neuropathy as compared to patients without neuropathy (estimated space of distribution 29 vs 20 l). Our results suggest that patients with diabetic neuropathy do not adjust the plasma adrenaline concentration to changes in adrenaline infusion rate as rapidly...... as those without neuropathy, i.e. the effect of an elevated adrenaline secretion rate may be prolonged in patients with diabetic autonomic neuropathy....

  10. Electrostatic energy analyzer measurements of low energy zirconium beam parameters in a plasma sputter-type negative ion source.

    Science.gov (United States)

    Malapit, Giovanni M; Mahinay, Christian Lorenz S; Poral, Matthew D; Ramos, Henry J

    2012-02-01

    A plasma sputter-type negative ion source is utilized to produce and detect negative Zr ions with energies between 150 and 450 eV via a retarding potential-type electrostatic energy analyzer. Traditional and modified semi-cylindrical Faraday cups (FC) inside the analyzer are employed to sample negative Zr ions and measure corresponding ion currents. The traditional FC registered indistinct ion current readings which are attributed to backscattering of ions and secondary electron emissions. The modified Faraday cup with biased repeller guard ring, cut out these signal distortions leaving only ringings as issues which are theoretically compensated by fitting a sigmoidal function into the data. The mean energy and energy spread are calculated using the ion current versus retarding potential data while the beam width values are determined from the data of the transverse measurement of ion current. The most energetic negative Zr ions yield tighter energy spread at 4.11 eV compared to the least energetic negative Zr ions at 4.79 eV. The smallest calculated beam width is 1.04 cm for the negative Zr ions with the highest mean energy indicating a more focused beam in contrast to the less energetic negative Zr ions due to space charge forces.

  11. Mechanical and Chemical Characterization of a TiC/C System Synthesized Using a Focus Plasma Arc.

    Directory of Open Access Journals (Sweden)

    Reza Mahmoodian

    Full Text Available Titanium carbide-graphite (TiC/C composite was successfully synthesized from Ti and C starting elemental powders using self-propagating high-temperature synthesis technique in an ultra-high plasma inert medium in a single stage. The TiC was exposed to a high-temperature inert medium to allow recrystallization. The product was then characterized using field emission scanning electron microscopy (FESEM coupled with energy dispersive X-ray analysis (EDX, X-ray diffraction (XRD, Rietveld refinement, nanoindentation, and micro-hardness to determine the product's properties. The recorded micro-hardness of the product was 3660 HV, which is a 14% enhancement and makes is comparable to TiC materials.

  12. Plasma matrix metalloproteinases, low density lipoprotein oxidisability and soluble adhesion molecules after a glucose load in Type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Brown Jackie

    2004-06-01

    Full Text Available Abstract Background Acute hyperglycaemia is an independent cardiovascular risk factor in Type 2 diabetes which may be mediated through increased oxidative damage to plasma low density lipoprotein, and in vitro, high glucose concentrations promote proatherogenic adhesion molecule expression and matrix metalloproteinase expression. Methods We examined these atherogenic risk markers in 21 subjects with Type 2 diabetes and 20 controls during an oral 75 g glucose tolerance test. Plasma soluble adhesion molecule concentrations [E-selectin, VCAM-1 and ICAM-1], plasma matrix metalloproteinases [MMP-3 and 9] and plasma LDL oxidisability were measured at 30 minute intervals. Results In the diabetes group, the concentrations of all plasma soluble adhesion molecules fell promptly [all p Conclusions A glucose load leads to a rapid fall in plasma soluble adhesion molecule concentrations in Type 2 diabetes and controls, perhaps reflecting reduced generation of soluble from membrane forms during enhanced leukocyte – endothelial adhesion or increased hepatic clearance, without changes in plasma matrix metalloproteinase concentrations or low density lipoprotein oxidisability. These in vivo findings are in contrast with in vitro data.

  13. Validation of the Aerosol Beam-Focused Laser-Induced Plasma Spectrometer (ABF-LIPS) for Metal Emission Characterization

    Science.gov (United States)

    2010-03-01

    Figure 2-3 Focusing Simulation by Computational Fluid Dynamic ( CFD ) Modeling ... 6 Figure 2-4 ABF-LIPS prototype...32 Figure 5-8 Sampling location for ABF-LIPS and reference method during September 2005 test on platform prior to baghouse ...CAAA Clean Air Act Amendments CCD Charge Coupled Device CEMS Continuous Emission Monitoring System CFD Computational Fluid Dynamic CFR Code of

  14. Postprandial plasma fructose level is associated with retinopathy in patients with type 2 diabetes.

    Science.gov (United States)

    Kawasaki, Takahiro; Ogata, Nobuyuki; Akanuma, Hiroshi; Sakai, Tadashi; Watanabe, Hiroyuki; Ichiyanagi, Kaoru; Yamanouchi, Toshikazu

    2004-05-01

    The aim of the present study was to investigate the association of fructose on microangiopathy in patients with diabetes. Postprandial plasma fructose concentrations and postprandial plasma glucose concentrations were simultaneously measured 3 times within a 24-hour period (2 hours after each meal) in 38 patients with type 2 diabetes that had been admitted to the hospital. The mean postprandial plasma fructose concentrations (MPPF) and the mean postprandial plasma glucose concentrations (MPPG) were calculated. Fructose was measured by gas chromatography-mass spectrometry (GCMS). Based solely on MPPF, we were able to divide the patients into three groups: the high MPPF (31.9 +/- 6.5 micromol/L) group (n = 12), the middle MPPF (21.2 +/- 1.8 micromol/L) group (n = 13), and the low MPPF (15.2 +/- 2.4 micromol/L) group (n = 13). Prevalence and degree of retinopathy and nephropathy were then evaluated in the 3 different groups. A significant correlation was observed in the prevalence of proliferative diabetic retinopathy (PDR) among the 3 MPPF groups (P =.024). The prevalence of PDR was higher in the high MPPF group (75.0%) than in the middle and low MPPF groups (23.1% and 38.5%, respectively). Although not significantly different statistically, the prevalence of all degrees of retinopathy showed a tendency to be higher in the high MPPF group (83.3%) than in the middle and low MPPF groups (46.2% and 46.2%, respectively) (P =.081). Nephropathy prevalence also showed a tendency to be higher in the high MPPF group (66.7%) than in the middle and low MPPF groups (38.5% and 30.8%, respectively), although the differences were not significant. The prevalence of clinical albuminuria was not significantly different among the 3 groups, but there was a tendency for it to be higher in the low MPPF group (30.8%) than in the high and middle MPPF groups (16.7% and 0%, respectively). No significant differences in glycemic indicators and mean duration of diabetes were observed among the 3

  15. Regular physical exercise training assists in preventing type 2 diabetes development: focus on its antioxidant and anti-inflammatory properties

    Directory of Open Access Journals (Sweden)

    Reis Flávio

    2011-01-01

    Full Text Available Abstract Diabetes mellitus has emerged as one of the main alarms to human health in the 21st century. Pronounced changes in the human environment, behavior and lifestyle have accompanied globalization, which resulted in escalating rates of both obesity and diabetes, already described as diabesity. This pandemic causes deterioration of life quality with high socio-economic costs, particularly due to premature morbidity and mortality. To avoid late complications of type 2 diabetes and related costs, primary prevention and early treatment are therefore necessary. In this context, effective non-pharmacological measures, such as regular physical activity, are imperative to avoid complications, as well as polymedication, which is associated with serious side-effects and drug-to-drug interactions. Our previous work showed, in an animal model of obese type 2 diabetes, the Zucker Diabetic Fatty (ZDF rat, that regular and moderate intensity physical exercise (training is able, per se, to attenuate insulin resistance and control glycaemia, dyslipidaemia and blood pressure, thus reducing cardiovascular risk, by interfering with the pathophysiological mechanisms at different levels, including oxidative stress and low-grade inflammation, which are key features of diabesity. This paper briefly reviews the wide pathophysiological pathways associated with Type 2 diabetes and then discusses in detail the benefits of training therapy on glycaemic control and on cardiovascular risk profile in Type 2 diabetes, focusing particularly on antioxidant and anti-inflammatory properties. Based on the current knowledge, including our own findings using an animal model, it is concluded that regular and moderate intensity physical exercise (training, due to its pleiotropic effects, could replace, or at least reduce, the use of anti-diabetic drugs, as well as of other drugs given for the control of cardiovascular risk factors in obese type 2 diabetic patients, working as a

  16. Re-appraisal and extension of the Gratton-Vargas two-dimensional analytical snowplow model of plasma focus - Part II: Looking at the singularity

    CERN Document Server

    Auluck, S K H

    2016-01-01

    The Gratton-Vargas snowplow model, recently revisited and expanded (S K H Auluck, Physics of Plasmas, 20, 112501 (2013)), has given rise to significant new insights into some aspects of the Dense Plasma Focus (DPF), in spite of being a purely kinematic description having no reference to plasma phenomena. It is able to provide a good fit to the experimental current waveforms in at least 4 large facilities. It has been used for construction of a local curvilinear frame of reference, in which conservation laws for mass, momentum and energy can be reduced to effectively-one-dimensional hyperbolic conservation law equations. Its utility in global parameter optimization of device parameters has been demonstrated. These features suggest that the Gratton-Vargas model deserves a closer look at its supposed limitations near the singular phase of the DPF. This paper presents a discussion of its development near the device axis, based on the original work of Gratton and Vargas, with some differences. It is shown that the...

  17. Hepatocyte growth factor activator is a potential target proteinase for Kazal-type inhibitor in turkey (Meleagris gallopavo) seminal plasma.

    Science.gov (United States)

    Słowińska, Mariola; Bukowska, Joanna; Hejmej, Anna; Bilińska, Barbara; Kozłowski, Krzysztof; Jankowski, Jan; Ciereszko, Andrzej

    2015-08-01

    A peculiar characteristic of turkey seminal plasma is the increased activity of serine proteinases. It is of interest if the single-domain Kazal-type inhibitor controls the activity of turkey seminal plasma proteinases. Pure preparations of the Kazal-type inhibitor and anti-Kazal-type inhibitor monospecific immunoglobulin Gs were used as ligands in affinity chromatography for proteinase isolation from turkey seminal plasma. Gene expression and the immunohistochemical detection of the single-domain Kazal-type inhibitor in the reproductive tract of turkey toms are described. The hepatocyte growth factor activator (HGFA) was identified in the binding fraction in affinity chromatography. Hepatocyte growth factor activator activity was inhibited by the Kazal-type inhibitor in a dose-dependent manner. This protease was a primary physiological target for the single-domain Kazal-type inhibitor. Numerous proteoforms of HGFA were present in turkey seminal plasma, and phosphorylation was the primary posttranslational modification of HGFA. In addition to HGFA, acrosin was a target proteinase for the single-domain Kazal-type inhibitor. In seminal plasma, acrosin was present only in complexes with the Kazal-type inhibitor and was not present as a free enzyme. The single-domain Kazal-type inhibitor was specific for the reproductive tract. The germ cell-specific expression of Kazal-type inhibitors in the testis indicated an important function in spermatogenesis; secretion by the epithelial cells of the epididymis and the ductus deferens indicated that the Kazal-type inhibitor was an important factor involved in the changes in sperm membranes during maturation and in the maintenance of the microenvironment in which sperm maturation occurred and sperm was stored. The role of HGFA in these processes remains to be established.

  18. Use of delayed gamma rays for active non-destructive assay of {sup 235}U irradiated by pulsed neutron source (plasma focus)

    Energy Technology Data Exchange (ETDEWEB)

    Andola, Sanjay; Niranjan, Ram [Applied Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Kaushik, T.C., E-mail: tckk@barc.gov.in [Applied Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Rout, R.K. [Applied Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Kumar, Ashwani; Paranjape, D.B.; Kumar, Pradeep; Tomar, B.S.; Ramakumar, K.L. [Radioanalytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Gupta, S.C. [Applied Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2014-07-01

    A pulsed neutron source based on plasma focus device has been used for active interrogation and assay of {sup 235}U by monitoring its delayed high energy γ-rays. The method involves irradiation of fissile material by thermal neutrons obtained after moderation of a burst of neutrons emitted upon fusion of deuterium in plasma focus (PF) device. The delayed gamma rays emitted from the fissile material as a consequence of induced fission were detected by a large volume sodium iodide (NaI(Tl)) detector. The detector is coupled to a data acquisition system of 2k input size with 2k ADC conversion gain. Counting was carried out in pulse height analysis mode for time integrated counts up to 100 s while the temporal profile of delayed gamma has been obtained by counting in multichannel scaling mode with dwell time of 50 ms. To avoid the effect of passive (natural) and active (from surrounding materials) backgrounds, counts have been acquired for gamma energy between 3 and 10 MeV. The lower limit of detection of {sup 235}U in the oxide samples with this set-up is estimated to be 14 mg.

  19. Low-dose spironolactone reduces plasma fibulin-1 levels in patients with type 2 diabetes and resistant hypertension

    DEFF Research Database (Denmark)

    Stolzenburg Oxlund, Christina; Cangemi, Claudia; Henriksen, J E

    2015-01-01

    whether antihypertensive treatment with spironolactone changes plasma fibulin-1 levels. In a multicenter, double-blind, randomized, placebo-controlled study, 119 patients with type 2 diabetes and resistant hypertension were included. A dose of spironolactone 25 mg or matching placebo was added to previous...... treatment (P=0.009), but increased after placebo (P=0.017). Baseline plasma fibulin-1 correlated with BP and estimated glomerular filtration rate. Increased levels of plasma fibulin-1 (P=0.004) were observed in diabetic participants reporting erectile dysfunction as compared with participants who did not....... Treatment with low-dose spironolactone reduced plasma fibulin-1 levels in patients with type 2 diabetes and resistant hypertension. This supports the hypothesis that the antihypertensive effect of the mineralocorticoid receptor blocker in part may be due to regression of vascular remodeling....

  20. Validation of plasma microRNAs as biomarkers for myotonic dystrophy type 1.

    Science.gov (United States)

    Perfetti, A; Greco, S; Cardani, R; Fossati, B; Cuomo, G; Valaperta, R; Ambrogi, F; Cortese, A; Botta, A; Mignarri, A; Santoro, M; Gaetano, C; Costa, E; Dotti, M T; Silvestri, G; Massa, R; Meola, G; Martelli, F

    2016-12-01

    Non-invasive and simple to measure biomarkers are still an unmet need for myotonic dystrophy type 1 (DM1). Indeed, muscle biopsies can be extremely informative, but their invasive nature limits their application. Extracellular microRNAs are emerging humoral biomarkers and preliminary studies identified a group of miRNAs that are deregulated in the plasma or serum of small groups of DM1 patients. Here we adopted very stringent selection and normalization criteria to validate or disprove these miRNAs in 103 DM1 patients and 111 matched controls. We confirmed that 8 miRNAs out of 12 were significantly deregulated in DM1 patients: miR-1, miR-27b, miR-133a, miR-133b, miR-206, miR-140-3p, miR-454 and miR-574. The levels of these miRNAs, alone or in combination, discriminated DM1 from controls significantly, and correlated with both skeletal muscle strength and creatine kinase values. Interestingly, miR-133b levels were significantly higher in DM1 female patients. Finally, the identified miRNAs were also deregulated in the plasma of a small group (n = 30) of DM2 patients. In conclusion, this study proposes that miRNAs might be useful as DM1 humoral biomarkers.

  1. Validation of plasma microRNAs as biomarkers for myotonic dystrophy type 1

    Science.gov (United States)

    Perfetti, A.; Greco, S.; Cardani, R.; Fossati, B.; Cuomo, G.; Valaperta, R.; Ambrogi, F.; Cortese, A.; Botta, A.; Mignarri, A.; Santoro, M.; Gaetano, C.; Costa, E.; Dotti, M. T.; Silvestri, G.; Massa, R.; Meola, G.; Martelli, F.

    2016-01-01

    Non-invasive and simple to measure biomarkers are still an unmet need for myotonic dystrophy type 1 (DM1). Indeed, muscle biopsies can be extremely informative, but their invasive nature limits their application. Extracellular microRNAs are emerging humoral biomarkers and preliminary studies identified a group of miRNAs that are deregulated in the plasma or serum of small groups of DM1 patients. Here we adopted very stringent selection and normalization criteria to validate or disprove these miRNAs in 103 DM1 patients and 111 matched controls. We confirmed that 8 miRNAs out of 12 were significantly deregulated in DM1 patients: miR-1, miR-27b, miR-133a, miR-133b, miR-206, miR-140-3p, miR-454 and miR-574. The levels of these miRNAs, alone or in combination, discriminated DM1 from controls significantly, and correlated with both skeletal muscle strength and creatine kinase values. Interestingly, miR-133b levels were significantly higher in DM1 female patients. Finally, the identified miRNAs were also deregulated in the plasma of a small group (n = 30) of DM2 patients. In conclusion, this study proposes that miRNAs might be useful as DM1 humoral biomarkers. PMID:27905532

  2. Fraunhofer-type absorption line splitting and polarization in confocal double-pulse laser induced plasma

    Energy Technology Data Exchange (ETDEWEB)

    Nagli, Lev, E-mail: nagli@post.tau.ac.il; Gaft, Michael

    2013-10-01

    Strong line splitting and polarization are observed in Fraunhofer-type absorption lines in Pb, Sn, Si, Cd, In, and Zn in confocal double-pulse laser induced plasma (DP-LIP) experiments. This effect is detectable using medium laser power densities: (∼ 1–2) × 10{sup 13} W/m{sup 2} for the first laser pulse and 1 × 10{sup 14} W/m{sup 2} for the second laser pulse. Polarization and splitting effects exist only during the second laser pulse (∼ 7 ns). Absorption line polarization and splitting phenomena may be explained by a high overall magnetic field and motional Stark effect caused by the second laser pulse inside the laser plasma created by the first pulse. - Highlights: • Certain Fraunhofer absorption lines in DP LIBS are polarized. • Certain Fraunhofer absorption lines in DP LIBS are split. • Those effects exist during laser pulse. • Effects take place in elements with ns{sup 2}np{sup 2} and ns{sup 2} electron ground state.

  3. Thermal Design of a Bitter-Type Electromagnet for Dusty Plasma Experiments: Prototype Design and Construction

    Science.gov (United States)

    Birmingham, W. J.; Bates, E. M.; Romero-Talamás, Carlos; Rivera, W. F.

    2015-11-01

    For the purpose of analyzing magnetized dusty plasma at the University of Maryland Baltimore County (UMBC) Dusty Plasma Laboratory, we are designing a resistive water cooled Bitter-Type electromagnet. When completed, the magnet will be programmable to generate fields of up to 10 T for at least 10 seconds and up to several minutes. An analytic thermal design method was developed for establishing the location of elongated axial cooling passages. Comparisons with finite element analysis (FEA) data reveals that the thermal design method was capable of generating cooling channel patterns which establish manageable temperature profiles within the magnet. With our analytic method, cooling hole patterns can be generated in seconds instead of hours with FEA software. To further validate our thermal analysis as well as manufacturing techniques of our magnet design, we are now constructing a prototype electromagnet. The prototype is designed to operate continuously at 1 T with a current of 750 A, and has four diagnostic ports that can accommodate thermocouples and optical access to the water flow. A 1.25 inch diameter bore allows for axial field measurements and provides space for small scale experiments. Thermal analysis and specifics of the electromagnet design are presented.

  4. Plasma thyroid hormone concentration is associated with hepatic triglyceride content in patients with type 2 diabetes.

    Science.gov (United States)

    Bril, Fernando; Kadiyala, Sushma; Portillo Sanchez, Paola; Sunny, Nishanth E; Biernacki, Diane; Maximos, Maryann; Kalavalapalli, Srilaxmi; Lomonaco, Romina; Suman, Amitabh; Cusi, Kenneth

    2016-01-01

    The underlying mechanisms responsible for the development and progression of non-alcoholic fatty liver disease (NAFLD) in patients with type 2 diabetes mellitus (T2DM) are unclear. Since the thyroid hormone regulates mitochondrial function in the liver, we designed this study in order to establish the association between plasma free T4 levels and hepatic triglyceride accumulation and histological severity of liver disease in patients with T2DM and NAFLD. This is a cross-sectional study including a total of 232 patients with T2DM. All patients underwent a liver MR spectroscopy ((1)H-MRS) to quantify hepatic triglyceride content, and an oral glucose tolerance test to estimate insulin resistance. A liver biopsy was performed in patients with a diagnosis of NAFLD. Patients were divided into 5 groups according to plasma free T4 quintiles. We observed that decreasing free T4 levels were associated with an increasing prevalence of NAFLD (from 55% if free T4≥1.18 ng/dL to 80% if free T4triglyceride accumulation by (1)H-MRS (ptriglyceride content in patients with T2DM. These results suggest that thyroid hormone may play a role in the regulation of hepatic steatosis and support the notion that hypothyroidism may be associated with NAFLD. No NCT number required. Copyright © 2016 American Federation for Medical Research.

  5. Self-excitation of microwave oscillations in plasma-assisted slow-wave oscillators by an electron beam with a movable focus.

    Science.gov (United States)

    Bliokh, Yu P; Nusinovich, G S; Shkvarunets, A G; Carmel, Y

    2004-10-01

    Plasma-assisted slow-wave oscillators (pasotrons) operate without external magnetic fields, which makes these devices quite compact and lightweight. Beam focusing in pasotrons is provided by ions, which appear in the device due to the impact ionization of a neutral gas by beam electrons. Typically, the ionization time is on the order of the rise time of the beam current. This means that, during the rise of the current, beam focusing by ions becomes stronger. Correspondingly, a beam of electrons, which was initially diverging radially due to the self-electric field, starts to be focused by ions, and this focus moves towards the gun as the ion density increases. This feature makes the self-excitation of electromagnetic (em) oscillations in pasotrons quite different from practically all other microwave sources where em oscillations are excited by a stationary electron beam. The process of self-excitation of em oscillations has been studied both theoretically and experimentally. It is shown that in pasotrons, during the beam current rise the amount of current entering the interaction space and the beam coupling to the em field vary. As a result, the self-excitation can proceed faster than in conventional microwave sources with similar operating parameters such as the operating frequency, cavity quality-factor and the beam current and voltage.

  6. Selenium, zinc and copper in plasma of patients with type 1 diabetes mellitus in different metabolic control states

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, C.; Alegria, A.; Barbera, R.; Farre, R.; Lagarda, M.J. [Valencia Univ. (Spain). Lab. of Nutrition and Food Chemistry

    1998-07-01

    The Studies of selenium (Se), zinc (Zn) and copper (Cu) levels in diabetic patients have led to contradictory findings as to the possible relationship between the degree of diabetic control and the changes in mineral contents. In the present study the plasma Cu, Se and Zn contents of diabetic patients and healthy people were measured and the relationship between these contents and diabetic metabolic control, as determined by glycosylated hemoglobin (HbA{sub 1c}), was studied. The mean plasma Se content in diabetic patients was significantly lower than in controls (p<0.01) and a negative correlation between the plasma contents of Se and HbA{sub 1c} was found. No statistically significant differences in plasma Zn contents, either between patients with type 1 diabetes mellitus and controls, or between patients with type 1 diabetes mellitus but different degrees of metabolic control, were found. A statistically significant sex difference in plasma Cu contents was observed in the control population. In females, statistically significant differences were found in plasma Cu contents between the control subjects and the diabetic patients with medium or poor metabolic control, as well as between diabetic patients with good and poor metabolic control. In males, the only statistically significant differences were between the control subjects and diabetic patients with poor metabolic control. The correlation between plasma contents of Cu and HbA{sub 1c} is not significant. (orig.)

  7. CORRELATION OF FASTING AND POST-PRANDIAL PLASMA GLUCOSE WITH GLYCATED HEMOGLOBIN IN PATIENTS WITH DIABETIC TYPE 2

    Directory of Open Access Journals (Sweden)

    HASAN SAFAEI

    2003-12-01

    Full Text Available Introduction: Meaurment of glycated hamoglobin is the accepted indicator of long therm glycemic control. This study wase done to evaluate the relative value beetwen plasma glucose at different time point and glycated gemoglubin. RESEARCH DESIGN AND METHODS: This is a descriptive cross sectional study on type 2 diabetic patients who reffered to Isfahan endocrin and reaserch center. Each two week or month giycemic pofiles . le, plasma glucose at prebreakfast (8:00 AM 2 hour postprandial and Extended post Lunch (5:00PM times points plasma glucose were compared with measurement of glycated hemoglobin (HbA1C after 3 months. Result were analysed by multiple linear regression and pyerson correlation confidence. RESULTS: Mean plasma glucose for Fasting, 2 hpp, 5 PM and HbA1C was 147.3±57.08 1999.83 ± 52.99, 178.68 ±68.17 and 9.35 ±1.5 and corelation confidence between plasma glucose and HbA1C 0.316 , 0.460 and 0.548 Respectively. Multiple regression between plasmaglucose and glycated hemoglobin was 0.651 with p< 0.0001. Conclusions: in type 2 diaabetic patients extended postlumch (5:00 PM plasma glucose and 2 hour postprandial are beter correlation with HbA1C than fasting plasma glucose.

  8. Effectiveness of music therapy on focused attention, working memory and stress in Type 2 diabetes: An exploratory study

    Directory of Open Access Journals (Sweden)

    Indira Tumuluri

    2017-01-01

    Full Text Available Cognitive deficits are reported in diabetes mellitus type 2 (DM2. Previous research has shown that music-based intervention can not only reduce hyperglycemia but also target cognitive functions as well as stress. The aim of this exploratory study was to understand the effect of active participation in music therapy (MT on the cognitive deficits of DM2 patients. MT of twenty sessions was carried out with three participants with DM2. Serum cortisol, perceived stress, Color Trail Test (1 and 2, and verbal n-back (1 and 2 tests were used to measure the outcomes. Feedback was taken for the subjective ratings and satisfaction of the participants. Stress and cortisol reduced and focused attention and working memory improved in varying degrees. Subjectively, participants reported having benefitted from the intervention. This is the first attempt to investigate the effect of music-based intervention on cognitive function in DM2 patients using case study approach.

  9. Discriminating between cardiac and pulmonary dysfunction in the general population with dyspnea by plasma pro-B-type natriuretic peptide

    DEFF Research Database (Denmark)

    Mogelvang, R; Goetze, JP; Schnohr, P;

    2007-01-01

    OBJECTIVES: This study was designed to determine whether measurement of plasma pro-B-type natriuretic peptide (proBNP) could be used in discriminating between cardiac and pulmonary dyspnea in the general population. BACKGROUND: Natriuretic peptides are useful markers in ruling out acute cardiac...... the expected concentration of plasma proBNP based on age and gender was established for dyspneic subjects: an actual plasma proBNP concentration below half of the expected value ruled out left ventricular systolic and diastolic dysfunction (sensitivity 100%, 95% CI 100% to 100%; specificity 15%, 95% CI 12...

  10. Discriminating between cardiac and pulmonary dysfunction in the general population with dyspnea by plasma pro-B-type natriuretic peptide

    DEFF Research Database (Denmark)

    Mogelvang, R; Goetze, JP; Schnohr, P

    2007-01-01

    OBJECTIVES: This study was designed to determine whether measurement of plasma pro-B-type natriuretic peptide (proBNP) could be used in discriminating between cardiac and pulmonary dyspnea in the general population. BACKGROUND: Natriuretic peptides are useful markers in ruling out acute cardiac...... with dyspnea, left ventricular hypertrophy and/or systolic dysfunction was associated with a 2.6-fold increase in plasma proBNP concentration (p ...% to 17%). CONCLUSIONS: In the general population with dyspnea, plasma proBNP concentrations are increased in left ventricular dilatation, hypertrophy, systolic dysfunction, or diastolic dysfunction, but are unaffected by pulmonary dysfunction....

  11. Cumulative effect of Weibel-type instabilities in counterstreaming plasmas with non-Maxwellian anisotropies

    CERN Document Server

    Lázár, M; Shukla, P K

    2008-01-01

    Counterstreaming plasma structures are widely present in laboratory experiments and astrophysical systems, and they are investigated either to prevent unstable modes arising in beam-plasma experiments or to prove the existence of large scale magnetic fields in astrophysical objects. Filamentation instability arises in a counterstreaming plasma and is responsible for the magnetization of the plasma. Filamentationally unstable mode is described by assuming that each of the counterstreaming plasmas has an isotropic Lorentzian (kappa) distribution. In this case, the filamentation instability growth rate can reach a maximum value markedly larger than that for a a plasma with a Maxwellian distribution function. This behaviour is opposite to what was observed for the Weibel instability growth rate in a bi-kappa plasma, which is always smaller than that obtained for a bi-Maxwellian plasma. The approach is further generalized for a counterstreaming plasma with a bi-kappa temperature anisotropy. In this case, the filam...

  12. RF electric field penetration and power deposition into nonequilibrium planar-type inductively coupled plasmas

    Institute of Scientific and Technical Information of China (English)

    Mao Ming; Wang Shuai; Dai Zhong-Ling; Wang You-Nian

    2007-01-01

    The RF electric field penetration and the power deposition into planar-type inductively coupled plasmas in lowpressure discharges have been studied by means of a self-consistent model which consists of Maxwell equations combined with the kinetic equation of electrons. The Maxwell equations are solved based on the expansion of the Fourier-Bessel series for determining the RF electric field. Numerical results show the influence of a non-Maxwellian electron energy distribution on the RF electric field penetration and the power deposition for different coil currents. Moreover, the two-dimensional spatial profiles of RF electric field and power density are also shown for different numbers of RF coil turns.

  13. Postprandial Plasma Concentrations of Individual Bile Acids and FGF-19 in Patients With Type 2 Diabetes

    DEFF Research Database (Denmark)

    Sonne, David P; van Nierop, F Samuel; Kulik, Willem

    2016-01-01

    CONTEXT: Bile acids regulate lipid and carbohydrate metabolism by interaction with membrane or intracellular proteins including the nuclear farnesoid X receptor (FXR). Postprandial activation of ileal FXR leads to secretion of fibroblast growth factor 19 (FGF-19), a gut hormone that may be implic......CONTEXT: Bile acids regulate lipid and carbohydrate metabolism by interaction with membrane or intracellular proteins including the nuclear farnesoid X receptor (FXR). Postprandial activation of ileal FXR leads to secretion of fibroblast growth factor 19 (FGF-19), a gut hormone that may...... be implicated in postprandial glucose metabolism. OBJECTIVE: To describe postprandial plasma concentrations of 12 individual bile acids and FGF-19 in patients with type 2 diabetes (T2D) and healthy controls. DESIGN AND SETTING: Descriptive study, performed at the Center for Diabetes Research, Gentofte Hospital...... and FGF-19 concentrations. RESULTS: Postprandial total bile acid concentrations increased with increasing meal fat content (P

  14. Rapid changes in plasma androgens during insulin withdrawal in male type 1 (insulin-dependent) diabetics

    DEFF Research Database (Denmark)

    Madsbad, S; Gluud, C; Bennett, Patrick

    1986-01-01

    Plasma concentrations of testosterone, androstenedione and dihydrotestosterone were measured in 15 Type 1 (insulin-dependent) diabetics with (n = 8) and without (n = 7) B-cell function during 12 h of insulin withdrawal and compared with those of 8 normal subjects. Before insulin withdrawal...... no significant difference was found in androgen concentrations between the diabetic and the normal subjects. The normal diurnal profiles, with highest androgen concentrations in the morning before insulin withdrawal (08:00) and lowest concentrations at 20:00 h were maintained in the diabetics. However......, testosterone and dihydrotestosterone concentrations were lower in the diabetics after 4 h of insulin withdrawal and remained so throughout the study. The concentrations of androstenedione were not significantly different between diabetics and normal subjects except after 4 h of insulin withdrawal. Despite...

  15. Day-to-day variability of fasting plasma glucose in newly diagnosed type 2 diabetic subjects.

    Science.gov (United States)

    Ollerton, R L; Playle, R; Ahmed, K; Dunstan, F D; Luzio, S D; Owens, D R

    1999-03-01

    To determine the day-to-day intraindividual variability of fasting plasma glucose (FPG) in newly diagnosed Caucasian type 2 diabetic subjects. A total of 193 newly diagnosed, previously untreated, Caucasian type 2 diabetic subjects (135 men, 58 women) had FPG measured on two consecutive days (FPG1, FPG2). Ethical approval and subjects' full informed consent were obtained. Subjects fasted for 12 h before each study day and rested for at least 30 min before blood was taken. Plasma glucose was analyzed by a glucose oxidase method with intra- and interassay coefficients of variation (CVs) < 2%. Variability of FPG was assessed by comparison of percentage differences (PDs): PD = 100 (FPG2 - FPG1)/FPG1, with averaged FPG (FPGaver = [FPG1 + FPG2]/2). Biological and analytical variability were determined by use of SD2total = SD2biological + SD2analytical, where SD2analytical approximately equal to 2 x (CVglucose measurement)2. Given normally distributed data with zero mean, 95% of daily percentage differences will be expected to fall within a range of +/- 2 SDtotal. Subjects were age 54 +/- 10 years (mean +/- SD) and had BMI of 29.3 +/- 5.3 kg/m2. FPG values for both days were 12.2 +/- 3.4 mmol/l (FPG1) and 12.1 +/- 3.3 mmol/l (FPG2), with a mean paired difference (95% CI) of 0.1 (0.0 to 0.3) mmol/l. The variance of these differences increased with increasing FPGaver. The PDs did not exhibit this effect and were normally distributed (mean -0.6% [-1.7 to 0.4]; SD 7.4% [6.8 to 8.3]), giving a 95% variability (2 SD) of 14.8%. Biological variability (2 SDbiological) was 13.7%. No significant difference in PD was found between men and women (mean difference 1.3% [-1.0 to 3.6]; SDmale 7.4%, SDfemale 7.3%; P = 0.62). A total of 95% of the FPG values for this group of newly diagnosed type 2 diabetic subjects varied within approximately +/- 15% on a daily basis, with approximately 14% caused by biological variability. As these results are expressed in percentage terms, subjects in

  16. An evidence-based practice-oriented review focusing on canagliflozin in the management of type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Messana JA

    2017-02-01

    Full Text Available Joseph A Messana,1 Stanley S Schwartz,2,3 Raymond R Townsend1 1Nephrology Division, Perelman School of Medicine, University of Pennsylvania, 2Main Line Health, 3Department of Medicine, University of Pennsylvania, Philadelphia, PA, USA Abstract: Caring for patients with type 2 diabetes mellitus (T2DM has entered an era with many recent additions to the regimens used to clinically control their hyperglycemia. The most recent class of agents approved by the Food and Drug Administration (FDA for T2DM is the sodium–glucose-linked transporter type 2 (SGLT2 inhibitors, which work principally in the proximal tubule of the kidney to block filtered glucose reabsorption. In the few years attending this new class arrival in the market, there has been a great deal of interest generated by the novel mechanism of action of SGLT2 inhibitors and by recent large outcome trials suggesting benefit on important clinical outcomes such as death, cardiovascular disease and kidney disease progression. In this review, we focus on canagliflozin, the first-in-class marketed SGLT2 inhibitor in the USA. In some cases, we included data from other SGLT2 inhibitors, such as outcomes in clinical trials, important insights on clinical features and benefits, and adverse effects. These agents represent a fundamentally different way of controlling blood glucose and for the first time in T2DM care to offer the opportunity to reduce glucose, blood pressure, and weight with effects sustained for at least 2 years. Important side effects include genital mycotic infections and the potential for orthostatic hypotension and rare instances of normoglycemic ketoacidosis. Active ongoing clinical trials promise to deepen our experience with the potential benefits, as well as the clinical risks attending the use of this new group of antidiabetic agents. Keywords: SGLT2, canagliflozin, review, outcomes, type 2 diabetes mellitus 

  17. The relationship between MTHFR gene polymorphisms, plasma homocysteine levels and diabetic retinopathy in type 2 diabetes mellitus

    Institute of Scientific and Technical Information of China (English)

    孙家忠; 徐焱成; 朱宜莲; 鲁红云; 邓浩华; 范幼筠; 孙苏欣; 张颖

    2003-01-01

    Objective To evaluate the role of methylenetetrahydrofolate reductase (MTHFR) gene polymorphisms and plasma homocysteine levels in patients with type 2 diabetes mellitus and diabetic retinopathy (DR). Methods Total of 208 patients with type 2 diabetes mellitus and 57 controls were recruited into the study. MTHFR genetic C677T polymorphisms were determined by PCR-RFLP. Plasma total homocysteine levels were measured using high-performance liquid chromatography (HPLC) with fluorescence detection. Results The frequencies of MTHFR TT homogeneous type, CT heterogeneous type and allele T (28.18%, 41.82%, 49.09%) were significantly higher in the type 2 diabetes mellitus with diabetic retinopathy group than those without retinopathy (18.37%, 29.59%, 33.16%) and those of controls (17.54%, 28.07%, 31.58%). The presence of the T allele appeared to have a strong association with the development of diabetic retinopathy. The odds ratio was 1.94 with a 95% confidence interval of 1.31-2.88. Moreover, plasma homocysteine levels were remarkably higher in patients with TT or CT genotype than in patients with the CC genotype. Conclusion MTHFR gene C677T mutation associated with a predisposition to increased plasma homocysteine levels may be considered as a genetic risk factor for diabetic microangiopathy (such as DR) in Chinese patients with type 2 diabetes mellitus.

  18. Reduced plasma total homocysteine concentrations in Type 1 diabetes mellitus is determined by increased renal clearance.

    NARCIS (Netherlands)

    Veldman, B.A.J.; Vervoort, G.M.M.; Blom, H.J.; Smits, P.

    2005-01-01

    INTRODUCTION: Elevated plasma levels of total homocysteine are related to the development of vascular complications. Patients with diabetes mellitus are particularly at risk for the development of these complications. Several factors determine plasma total homocysteine including renal function.

  19. A Guillemin type E pulse forming network as the driver for a pulsed, high density plasma source.

    Science.gov (United States)

    Rathod, Priyavandna J; Anitha, V P; Sholapurwala, Z H; Saxena, Y C

    2014-06-01

    A Guillemin type E pulse forming network (PFN) has been designed, developed, and tested for its application in generating high density (~1 × 10(18) m(-3)) plasmas. In the present study, plasma thus generated is utilized to investigate the interaction of high power microwaves (HPMs) with plasma in an experimental architecture known as SYMPLE (System for Microwave PLasma Experiment). Plasma discharges of ~100 μs (max) duration are to be produced, by delivering energy of 5 kJ stored in a PFN to the plasma source, a washer gun. The output of the PFN, in terms of its rise time, flat top and amplitude, needs to be tailored, depending on the experimental requirements. An ignitron (NL8900) trigger generator (ITG) is developed in-house to control the PFN discharge through the gun. This ITG is also to be used in a circuit that synchronizes the HPM and plasma shots, to ensure that HPM-plasma interaction takes place during a temporal regime where appropriate parametric conditions are satisfied. Hence it is necessary to retain the jitter within ±2.5 μs. Further, requirement on plasma quiescence (~10%) necessitates maintaining the ripple within 5%. The developmental work of the PFN, keeping in view the above criteria and the test results, is presented in this paper. The parameters of the PFN have been analytically approximated and verified with PSPICE simulation. The test results presented include rise time ~5-8 μs, flat top variable in the range 20-100 μs, ripple within ~1.5%, and jitter within ±2.5 μs, producing quiescent (plasma discharge meeting the experimental requirements.

  20. Hard X-ray dose intensity and spatial distribution in a plasma focus device using thermoluminescence dosimeters

    Indian Academy of Sciences (India)

    A Kanani; M N Nasrabadi; B Shirani; I Jabbari

    2015-07-01

    In the present study, X-ray emission dose characteristics from a small Mather-type PF device in various pressures of argon as the operating gas were studied. The PF device was powered by a 12 F capacitor at 25 kV charging voltage. Time-integrated hard X-ray (HXR) emission was investigated using thermoluminescence dosimeters (TLDs). These detectors were calibrated with 60Co and 131Cs sources. Twenty-four dosimeters were placed at four different radial distances from the axis of the electrodes at the top of the anode to measure the dose spatial distribution at the top of the anode for different pressures (0.5–1.3 mbar). At each radius, six dosimeters were placed circularly with equal angular intervals on the inner surface of the device chamber. It was found that the optimum pressure for the highest yield of X-ray is 0.9 mbar. The maximum measured dose was 17 mGy per shot at the top of the anode and about 0.5 mGy per shot at 90° with respect to the anode axis. Furthermore, these results showed that the dose at each radius is symmetrical at 360° around the top of the anode, but X-ray distribution follows an anisotropical behaviour. A fast plastic scintillator was also used for time-resolved HXR detection, and a linear relation was observed between the amplitude of the scintillator-PMT signals and TLD responses.

  1. Plasma microRNAs as biomarkers for myotonic dystrophy type 1.

    Science.gov (United States)

    Perfetti, Alessandra; Greco, Simona; Bugiardini, Enrico; Cardani, Rosanna; Gaia, Paola; Gaetano, Carlo; Meola, Giovanni; Martelli, Fabio

    2014-06-01

    Myotonic dystrophy type 1 (DM1) lacks non-invasive and easy to measure biomarkers, still largely relying on semi-quantitative tests for diagnostic and prognostic purposes. Muscle biopsies provide valuable data, but their use is limited by their invasiveness. microRNA (miRNAs) are small non-coding RNAs regulating gene expression that are also present in biological fluids and may serve as diseases biomarkers. Thus, we tested plasma miRNAs in the blood of 36 DM1 patients and 36 controls. First, a wide miRNA panel was profiled in a patient subset, followed by validation using all recruited subjects. We identified a signature of nine deregulated miRNAs in DM1 patients: eight miRNAs were increased (miR-133a, miR-193b, miR-191, miR-140-3p, miR-454, miR-574, miR-885-5p, miR-886-3p) and one (miR-27b) was decreased. Next, the levels of these miRNAs were used to calculate a "DM1-miRNAs score". We found that both miR-133a levels and DM1-miRNAs score discriminated DM1 from controls significantly and Receiver-Operator Characteristic curves displayed an area under the curve of 0.94 and 0.97, respectively. Interestingly, both miR-133a levels and DM1-miRNAs score displayed an inverse correlation with skeletal muscle strength and displayed higher values in more compromised patients. In conclusion, we identified a characteristic plasma miRNA signature of DM1. Although preliminary, this study indicates miRNAs as potential DM1 humoral biomarkers. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Study of x-ray emission from a table top plasma focus and its application as an x-ray backlighter

    Science.gov (United States)

    Beg, F. N.; Ross, I.; Lorenz, A.; Worley, J. F.; Dangor, A. E.; Haines, M. G.

    2000-09-01

    A study of a 2 kJ, 200 kA, table top plasma focus device as an intense x-ray source is reported. The x-ray yield from a number of gases, (deuterium, nitrogen, neon, argon, and xenon) is measured as a function of filling pressure and in neon as a function of anode length. In gases with Zplasma implodes to form a uniform cylindrical column, whereas for Z⩾18, the plasma consists of a number of hot spots. A maximum x-ray yield of 16.6 J and pulse length of 10-15 ns was obtained in neon. The x-ray emission was established to be due to H- and He-like line radiation. The temperature estimated from spectroscopic observations was about 300-400 eV at an electron density of (3-5)×1020cm-3 in neon. At low pressures in neon, hard x-ray radiation, presumably due to electron beams was dominant. Mesh images of different wire materials were recorded at the optimum pressure in neon as a proof of principle for x-ray backlighting.

  3. Study of the effect of pyrex and quartz insulators on X-ray intensity in a 4 kJ plasma focus device

    Science.gov (United States)

    Koohestani, Saeedeh; Habibi, Morteza; Amrollahi, Reza

    2013-06-01

    In this paper we study the soft X-ray (SXR) and hard X-ray (HXR) intensity produced in different insulator sleeves by a 4 kJ plasma focus device (APF) using filtered PIN-diodes and a fast scintillation detector. The experiments were performed for a great number of neon filling gas pressures at voltages of 11, 12 and 13 kV. Lengths of 40 and 50 mm look optimal to yield the most SXR intensity for the Pyrex and Quartz insulators respectively. The device appears to optimize much better for Pyrex insulator than the Quartz. For Pyrex and Quartz insulators, the lengths of 40 mm and 50 mm seem optimal to yield maximum HXR intensity, respectively.

  4. Axial magnetic field and toroidally streaming fast ions in the dense plasma focus are natural consequences of conservation laws in the curved axisymmetric geometry of the current sheath

    CERN Document Server

    Auluck, S K H

    2014-01-01

    Direct measurement of axial magnetic field in the PF-1000 dense plasma focus (DPF), and its reported correlation with neutron emission, call for a fresh look at previous reports of existence of axial magnetic field component in the DPF from other laboratories, and associated data suggesting toroidal directionality of fast ions participating in fusion reactions, with a view to understand the underlying physics. In this context, recent work dealing with application of the hyperbolic conservation law formalism to the DPF is extended in this paper to a curvilinear coordinate system, which reflects the shape of the DPF current sheath. Locally-unidirectional shock propagation in this coordinate system enables construction of a system of 7 one-dimensional hyperbolic conservation law equations with geometric source terms, taking into account all the components of magnetic field and flow velocity. Rankine-Hugoniot jump conditions for this system lead to expressions for the axial magnetic field and three components of ...

  5. CORRELATION OF PLASMA FIBRINOGEN WITH BLOOD PRESSURE, BMI, LIPID PROFILE AND GLYCEMIC STATUS IN TYPE II D M

    Directory of Open Access Journals (Sweden)

    Suresh

    2014-12-01

    Full Text Available BACKGROUND: Diabetes is the most common metabolic disorder all over the world3.The incidence of diabetes is showing an alarming rise in developing countries, particularly in India. Type 2 diabetes is the most prevalent form in India and constitutes more than 95% of the cases.9 During the past decade, the potential role of haemostatic factors particularly fibrinogen in various disorders and their complication has gained considerable interest. Plasma fibrinogen is a important marker in type 2 Diabetes, but its correlation with smoking, age, sex, hypertension, obesity, family history lipids, has not been evaluated in large studies. In view of paucity of data from Indian studies, we attempt to correlate plasma fibrinogen with blood pressure, BMI, lipid profile and glycemic status in type 2 diabetes mellitus. METHODS: A total of 100, known and newly detected type-2 diabetic patients with and without associated hypertension of more than 40 years of age belonging to both sexes were included. All these patients were registered cases in Basaveshwar Teaching & General Hospital, Gulbarga as outpatients and in-patients. Type-2 diabetic patients associated with myocardial infarction, stroke, chronic inflammatory diseases, tuberculosis, malignancy, secondary hypertension and pregnancy were excluded from this study. After a detailed clinical examination, the following investigations were done: For diabetes mellitus: Random blood sugar, fasting blood sugar, post-prandial blood sugar and glycosylated haemoglobin (ERBA Kit. Renal profile: Blood urea and serum creatinine. Serum lipids: Cholesterol, triglyceride (TG, high density lipoprotein (HDL and low density lipoprotein (LDL by commercially available kits (ERBA Kit. Routine urine examination: Sugar and albumin. Estimation of plasma fibrinogen: The plasma fibrinogen was estimated by thrombin-clotting method by using FIBROQUANT KIT [Tulip Diagnostics (P Ltd.]. OBJECTIVES: To know the fibrinogen levels in patients

  6. An evidence-based practice-oriented review focusing on canagliflozin in the management of type 2 diabetes.

    Science.gov (United States)

    Messana, Joseph A; Schwartz, Stanley S; Townsend, Raymond R

    2017-01-01

    Caring for patients with type 2 diabetes mellitus (T2DM) has entered an era with many recent additions to the regimens used to clinically control their hyperglycemia. The most recent class of agents approved by the Food and Drug Administration (FDA) for T2DM is the sodium-glucose-linked transporter type 2 (SGLT2) inhibitors, which work principally in the proximal tubule of the kidney to block filtered glucose reabsorption. In the few years attending this new class arrival in the market, there has been a great deal of interest generated by the novel mechanism of action of SGLT2 inhibitors and by recent large outcome trials suggesting benefit on important clinical outcomes such as death, cardiovascular disease and kidney disease progression. In this review, we focus on canagliflozin, the first-in-class marketed SGLT2 inhibitor in the USA. In some cases, we included data from other SGLT2 inhibitors, such as outcomes in clinical trials, important insights on clinical features and benefits, and adverse effects. These agents represent a fundamentally different way of controlling blood glucose and for the first time in T2DM care to offer the opportunity to reduce glucose, blood pressure, and weight with effects sustained for at least 2 years. Important side effects include genital mycotic infections and the potential for orthostatic hypotension and rare instances of normoglycemic ketoacidosis. Active ongoing clinical trials promise to deepen our experience with the potential benefits, as well as the clinical risks attending the use of this new group of antidiabetic agents.

  7. An evidence-based practice-oriented review focusing on canagliflozin in the management of type 2 diabetes

    Science.gov (United States)

    Messana, Joseph A; Schwartz, Stanley S; Townsend, Raymond R

    2017-01-01

    Caring for patients with type 2 diabetes mellitus (T2DM) has entered an era with many recent additions to the regimens used to clinically control their hyperglycemia. The most recent class of agents approved by the Food and Drug Administration (FDA) for T2DM is the sodium–glucose-linked transporter type 2 (SGLT2) inhibitors, which work principally in the proximal tubule of the kidney to block filtered glucose reabsorption. In the few years attending this new class arrival in the market, there has been a great deal of interest generated by the novel mechanism of action of SGLT2 inhibitors and by recent large outcome trials suggesting benefit on important clinical outcomes such as death, cardiovascular disease and kidney disease progression. In this review, we focus on canagliflozin, the first-in-class marketed SGLT2 inhibitor in the USA. In some cases, we included data from other SGLT2 inhibitors, such as outcomes in clinical trials, important insights on clinical features and benefits, and adverse effects. These agents represent a fundamentally different way of controlling blood glucose and for the first time in T2DM care to offer the opportunity to reduce glucose, blood pressure, and weight with effects sustained for at least 2 years. Important side effects include genital mycotic infections and the potential for orthostatic hypotension and rare instances of normoglycemic ketoacidosis. Active ongoing clinical trials promise to deepen our experience with the potential benefits, as well as the clinical risks attending the use of this new group of antidiabetic agents. PMID:28255241

  8. Experimental investigation of the ternary system Ni–Pd–Sn with special focus on the B8-type phase

    Energy Technology Data Exchange (ETDEWEB)

    Jandl, Isabella, E-mail: Isabella.jandl@univie.ac.at; Ipser, Herbert; Richter, Klaus W.

    2015-11-15

    The ternary alloy system Ni–Pd–Sn was investigated experimentally from 700 °C upwards, with special focus on the general NiAs-type compounds. The phase diagram and crystallographic parameters were studied by means of powder X-ray diffraction (XRD), differential thermal analysis (DTA), light optical microscopy (LOM) and scanning electron microscopy (SEM) in combination with energy dispersive X-ray spectroscopy (EDX). An isothermal section at 700 °C was constructed wherein a continuous phase field between the binary NiAs-type compounds γ (PdSn) and Ni{sub 3}Sn{sub 2} (high temperature modification) was detected. A series of samples throughout this phase field was used to investigate lattice parameter variations, occupation of the atomic sites and the melting behaviour. A partial ordering of the transition metals was observed. Moreover, three vertical sections at 30 at.%, 40 at.% and 50 at.% Sn were determined. Altogether, seven ternary invariant phase reactions were discovered: two ternary eutectic reactions, one ternary eutectoid reaction, three ternary transition reactions and one maximum. A complete reaction scheme for the investigated temperature range is given. Furthermore, a partial liquidus surface projection, except for the low-temperature Sn-rich region, was developed. - Highlights: • Detailed study of the ternary alloy system Ni–Pd–Sn. • 1 Isotherm, 3 vertical sections, a partial liquidus projection and a reaction scheme. • A continuous phase field, between γ and Ni{sub 3}Sn{sub 2}, was discovered. • Lattice parameters and structural features in this phase field were analysed. • A partial order of Ni and Pd in this phase field was observed.

  9. Plasma Antimicrobial Peptide LL-37 Level Is Inversely Associated with HDL Cholesterol Level in Patients with Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Shu Meguro

    2014-01-01

    Full Text Available Introduction. Relation between atherosclerosis and innate immunity has attracted attention. As the antimicrobial peptide, LL-37, could have an important role in atherosclerosis, we supposed that there could be a meaningful association of plasma LL-37 level with risk factors for cardiovascular disease in subjects with type 2 diabetes mellitus. Materials and Methods. We evaluated plasma LL-37 level and other clinical markers in Japanese subjects with type 2 diabetes mellitus (n=133, 115 men and 18 women; age 64.7±11.5 years; HbA1c 8.1±1.6%. Plasma level of LL-37 was measured by ELISA. Results. Mean plasma LL-37 level was 71.2±22.3 ng/mL. Plasma LL-37 level showed significant correlations with HDL cholesterol (r=−0.450, P<0.01, triglyceride (r=0.445, P<0.01, and high sensitive C-reactive protein (r=0.316, P<0.01 but no significant correlation with age, body mass index, HbA1c, estimated glomerular filtration rate, 25-hydroxyvitamin D, or vitamin D binding protein. Multiple linear regression analysis showed significant correlations of plasma LL-37 level with HDL cholesterol (β=−0.411, P<0.01 and high sensitive C-reactive protein (β=0.193, P<0.05. Conclusion. Plasma LL-37 level was positively correlated with inflammatory markers and negatively correlated with HDL cholesterol in patients with type 2 diabetes mellitus.

  10. Analytical isoelectric focusing of apolipoprotein B of human plasma low-density lipoproteins in the presence of a nonionic and a zwitterionic detergent.

    Science.gov (United States)

    Melnik, B C; Melnik, S F

    1988-06-01

    A method for the analytical isoelectric focusing of Nonidet-P40-delipidated apolipoprotein B of human plasma low-density lipoproteins has been developed. Isoelectric focusing was performed in the presence of the zwitterionic nondenaturing detergent Chaps, 3-[(3-cholamidopropyl)-dimethylammonio]-1-propane sulfonate, and the nonionic surfactant Nonidet-P40, polyoxyethyleneglycol p-t-octylphenol with a mean of 9.0 ethylene oxide units per molecule. Low-density lipoprotein (LDL) apolipoprotein B (apo-B) entered 3.75% polyacrylamide gels without precipitation at the sites of sample application, permitting apoprotein recoveries of greater than 90% in the migrating bands. LDL apo-B exhibited 10 distinguishable bands with apparent isoelectric points of 7.34 (band 1), 7.27 (band 2), 7.16 (band 3), 7.02 (band 4), 6.88 (band 5), 6.70 (band 6), 6.61 (band 7), 6.48 (band 8), 6.40 (band 9), and 6.24 (band 10), respectively. Bands 3 and 4, 6 and 7, as well as 8 and 9 could be identified as major double bands. When the focused apo-B was run in a second dimension by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, the same relative molecular weight of B-100 was obtained for all focused bands. After electrotransfer to nitrocellulose paper, all bands reacted with polyclonal anti-human LDL antibody. Furthermore, the detergent-solubilized apo-B retained the immunological properties of native low-density lipoproteins when tested by double immunodiffusion against polyvalent anti-human LDL sera.

  11. Initial phase hot corrosion mechanism of gas tunnel type plasma sprayed thermal barrier coatings

    Energy Technology Data Exchange (ETDEWEB)

    Yugeswaran, S. [Joining and Welding Research Institute, Osaka University, Osaka 567-0047 (Japan); Kobayashi, A., E-mail: kobayasi@jwri.osaka-u.ac.jp [Joining and Welding Research Institute, Osaka University, Osaka 567-0047 (Japan); Ananthapadmanabhan, P.V. [L and PT Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2012-04-25

    Highlights: Black-Right-Pointing-Pointer Free standing TBC specimens were prepared by gas tunnel type plasma spraying with thickness of around 300-400 {mu}m. Black-Right-Pointing-Pointer 50%8YSZ + 50%La{sub 2}Zr{sub 2}O{sub 7} composite coating shows superior hot corrosion resistance. Black-Right-Pointing-Pointer Corrosive crystals structure and phase transformation was well controlled in this coating. - Abstract: The hot corrosion resistance of the top layer in TBC is one of the main constructive factors which determines the lifetime of the coatings under critical operating environments. In the present study, 8 wt% yttria stabilized zirconia (8YSZ), lanthanum zirconate (La{sub 2}Zr{sub 2}O{sub 7}) and equal weight percentage of its composite (50%8YSZ + 50% La{sub 2}Zr{sub 2}O{sub 7}) coatings were prepared by using gas tunnel type plasma spray torch at optimum spraying conditions. The hot corrosion performances of the above thermal barrier coatings were examined against 40 wt%V{sub 2}O{sub 5}-60 wt%Na{sub 2}SO{sub 4} corrosive ash at 1173 K for 5 h in open air atmosphere. After hot-corrosion testing, the coating surface was studied using a scanning electron microscope to observe the microstructure and X-ray diffraction techniques were used to identify the phase compositions. The results showed that LaVO{sub 4} and YVO{sub 4} are the main hot corrosion products along with the ZrO{sub 2} phase transformation from tetragonal to monoclinic phases in La{sub 2}Zr{sub 2}O{sub 7} and 8YSZ coatings respectively. The microstructure and phase formation mechanism of the hot corrosion products varied with each coating and among these, composition of 50%8YSZ + 50%La{sub 2}Zr{sub 2}O{sub 7} coating exhibited least degradation against V{sub 2}O{sub 5}-Na{sub 2}SO{sub 4} corrosive environment compared to the other coatings.

  12. Plasma matrix metalloproteinases are associated with incident cardiovascular disease and all-cause mortality in patients with type 1 diabetes

    DEFF Research Database (Denmark)

    Peeters, S A; Engelen, Lian; Buijs, J

    2017-01-01

    BACKGROUND: Altered regulation of extracellular matrix remodeling by matrix metalloproteinases (MMPs) and tissue inhibitor of metalloproteinase (TIMP) may contribute to vascular complications in type 1 diabetes. We investigated associations between plasma MMP-1, -2, -3, -9, -10 and TIMP-1, and ca...

  13. Plasma proteomics classifiers improve risk prediction for renal disease in patients with hypertension or type 2 diabetes

    NARCIS (Netherlands)

    Pena, Michelle J.; Jankowski, Joachim; Heinze, Georg; Kohl, Maria; Heinzel, Andreas; Bakker, Stephan J. L.; Gansevoort, Ron T.; Rossing, Peter; de Zeeuw, Dick; Heerspink, Hiddo J. Lambers; Jankowski, Vera

    2015-01-01

    OBJECTIVE: Micro and macroalbuminuria are strong risk factors for progression of nephropathy in patients with hypertension or type 2 diabetes. Early detection of progression to micro and macroalbuminuria may facilitate prevention and treatment of renal diseases. We aimed to develop plasma proteomics

  14. ABNORMAL PLASMA NORADRENALINE RESPONSE AND EXERCISE INDUCED ALBUMINURIA IN TYPE-1 (INSULIN-DEPENDENT) DIABETES-MELLITUS

    NARCIS (Netherlands)

    HOOGENBERG, K; DULLAART, RPF

    1992-01-01

    Submaximal exercise provokes an abnormal elevation in albuminuria in type 1 (insulin-dependent) diabetes mellitus. Plasma catecholamines might be involved in this phenomenon by a renal vasoconstrictive effect. Twelve healthy subjects (Controls: albuminuria It is concluded that the exercise-induced p

  15. Plasma proteomics classifiers improve risk prediction for renal disease in patients with hypertension or type 2 diabetes

    NARCIS (Netherlands)

    Pena, Michelle J.; Jankowski, Joachim; Heinze, Georg; Kohl, Maria; Heinzel, Andreas; Bakker, Stephan J. L.; Gansevoort, Ron T.; Rossing, Peter; de Zeeuw, Dick; Heerspink, Hiddo J. Lambers; Jankowski, Vera

    2015-01-01

    OBJECTIVE: Micro and macroalbuminuria are strong risk factors for progression of nephropathy in patients with hypertension or type 2 diabetes. Early detection of progression to micro and macroalbuminuria may facilitate prevention and treatment of renal diseases. We aimed to develop plasma proteomics

  16. Urine and plasma metabolites predict the development of diabetic nephropathy in individuals with Type 2 diabetes mellitus

    NARCIS (Netherlands)

    Pena, M. J.; Lambers Heerspink, H. J.; Hellemons, M. E.; Friedrich, T.; Dallmann, G.; Lajer, M.; Bakker, S. J. L.; Gansevoort, R. T.; Rossing, P.; de Zeeuw, D.; Roscioni, S. S.

    Aims Early detection of individuals with Type 2 diabetes mellitus or hypertension at risk for micro- or macroalbuminuria may facilitate prevention and treatment of renal disease. We aimed to discover plasma and urine metabolites that predict the development of micro-or macroalbuminuria. Methods

  17. Correlation between Behavioural and Psychological Symptoms of Alzheimer Type Dementia and Plasma Homocysteine Concentration

    Directory of Open Access Journals (Sweden)

    Zhanjie Zheng

    2014-01-01

    Full Text Available The relationship between plasma homocysteine and behavioral and psychological symptoms of dementia (BPSD has not been specifically investigated in previous research. In this study, we compared plasma homocysteine (Hcy among 40 Alzheimer’s disease (AD patients with BPSD, 37 AD patients without BPSD, and 39 healthy controls. Our results evidenced that the plasma homocysteine levels in AD patients with BPSD and without BPSD were higher than healthy controls and that the plasma homocysteine concentration in AD patients with BPSD was the highest among the three groups. Significant correlation between plasma homocysteine concentration and cognitive decline and duration of dementia was observed, but there was no correlation between BPSD and cognitive dysfunction or duration of dementia. In conclusion, this study showed for the first time that BPSD were associated with plasma homocysteine concentration in Alzheimer's dementia, and the results supported that hyperhomocysteine may take part in the pathogenesis of BPSD.

  18. Evaluation of the Association of Plasma Pentraxin 3 Levels with Type 2 Diabetes and Diabetic Nephropathy in a Malay Population

    Directory of Open Access Journals (Sweden)

    Norhashimah Abu Seman

    2013-01-01

    Full Text Available Recent reports have demonstrated that elevated plasma long pentraxin 3 (PTX3 levels are associated with cardiovascular and chronic kidney diseases. In the current study, we investigated the plasma PTX3 levels in 296 Malay subjects including the subjects with normal glucose tolerance (NGT and type 2 diabetes (T2DM patients with or without DN by using an enzyme-linked immune-sorbent assay. Results showed that in males, plasma PTX3 levels in T2DM patients without DN were lower than that in the subjects with NGT (2.78 versus 3.98 ng/mL; P=0.021. Plasma PTX3 levels in T2DM patients with DN were decreased compared to the patients without DN (1.63 versus 2.78 ng/mL; P=0.013. In females, however, no significant alteration of plasma PTX3 levels among NGT subjects and T2DM patients with and without DN was detected. Furthermore, an inverse correlation between PTX3 and body mass index was found in male subjects with NGT (P=0.012; r=-0.390, but not in male T2DM patients, neither in all females. The current study provided the first evidence that decreased plasma PTX3 levels are associated with T2DM and DN in Malay men and also suggested that PTX3 may have different effects in DN and chronic kidney diseases.

  19. Plasma C-type natriuretic peptide as a predictor for therapeutic response to metoprolol in children with postural tachycardia syndrome.

    Directory of Open Access Journals (Sweden)

    Jing Lin

    Full Text Available POTS is a global public-health disease, but predictor for therapeutic response to metoprolol in children with POTS is lacking. This study was designed to investigate predictive value of plasma C-type natriuretic peptide (CNP in the therapeutic efficacy of metoprolol on postural tachycardia syndrome (POTS in children. Totally 34 children with POTS and 27 healthy children were included in the study. The head-up test or head-up tilt test was used to check heart rate and blood pressure from supine to upright in subjects. A double antibody (competitive sandwich immunoluminometric assay was used to detect plasma CNP. Metoprolol was used to treat children with POTS. The difference in plasma concentrations of CNP between responders and non-responders was compared. An ROC curve was used to analyze plasma CNP to predict efficacy of metoprolol on POTS in children. Plasma CNP in children with POTS was significantly higher than that of healthy children [(51.9 ± 31.4 vs. (25.1 ± 19.1 pg/ml, P 32.55 pg/ml yielded a sensitivity of 95.8% and specificity of 70% in predicting therapeutic efficacy of metoprolol on POTS children. Plasma CNP might serve as a useful predictor for the therapeutic efficacy of metoprolol on POTS in children.

  20. Effect of Resistance Training on Plasma Nitric Oxide and Asymmetric Dimethylarginine Concentrations in Type I Diabetic Rats

    Science.gov (United States)

    Esfahani, Parivash Shekarchizadeh; Gharakhanlou, Reza; Karimian, Jahangir; Khazaei, Majid; Feizi, Awat; Safarzade, Alireza

    2013-01-01

    Background: Asymmetric dimethylarginine (ADMA) has a predominant role in progression of some cardiovascular diseases, including diabetes. It interferes with L-arginine in production of nitric oxide (NO) by inhibition of NO synthase. The purpose of this study was to evaluate the effect of resistance training on plasma NO and ADMA concentrations in type 1 diabetic male rats. Methods: Thirty-six male wistar rats were randomly divided into four groups: (1) control; (2) diabetic; (3) diabetic trained, and (4) control trained (n = 9 each). In the trained groups, the animals undertook one training session per day, 3 days/week, for 4 weeks. At the end of experiment, blood samples were taken and the concentrations of plasma glucose, insulin, lipid profile, NO and ADMA concentrations were determined. Results: plasma ADMA concentration showed a significant increase in diabetic rats compare to control group (0.73 ± 0.07 vs. 0.62 ± 0.04 μmol/l; P < 0.05). The plasma ADMA level in the trained diabetic and control were lower than the sedentary groups, although it was not statistically significant. Plasma NO concentration in diabetic group was lower than control (P < 0.05). Resistance training significantly increased plasma NO concentration in diabetic animals (P < 0.05). Conclusion: Elevated ADMA level in diabetic animals can normalize during resistance exercise. Reduced ADMA level and increased NO level following resistance training might improve cardiovascular risk in diabetic subjects. PMID:23717776

  1. Modulation of electrical properties in Cu/n-type InP Schottky junctions using oxygen plasma treatment

    Science.gov (United States)

    Kim, Hogyoung; Cho, Yunae; Jung, Chan Yeong; Kim, Se Hyun; Kim, Dong-Wook

    2015-12-01

    Using current-voltage (I-V) measurements, we investigated the effect of oxygen plasma treatment on the temperature-dependent electrical properties of Cu/n-type indium phosphide (InP) Schottky contacts at temperatures in the range 100-300 K. Changes in the electrical parameters were evident below 180 K for the low-plasma-power sample (100 W), which is indicative of the presence of a wider distribution of regions of low barrier height. Modified Richardson plots were used to obtain Richardson constants, which were similar to the theoretical value of 9.4 A cm-2 K-2 for n-type InP. This suggests that, for all the samples, a thermionic emission model including a spatially inhomogeneous Schottky barrier can be used to describe the charge transport phenomena at the metal/semiconductor interface. The voltage dependence of the reverse-bias current revealed that Schottky emission was dominant for the untreated and high-plasma-power (250 W) samples. For the low-plasma-power sample, Poole-Frenkel emission was dominant at low voltages, whereas Schottky emission dominated at higher voltages. Defect states and nonuniformity of the interfacial layer appear to be significant in the reverse-bias charge transport properties of the low-plasma-power sample.

  2. On the Dirichlet Problem of Mixed Type for Lower Hybrid Waves in Axisymmetric Cold Plasmas

    Science.gov (United States)

    Lupo, Daniela; Monticelli, Dario D.; Payne, Kevin R.

    2015-07-01

    For a class of linear second order partial differential equations of mixed elliptic-hyperbolic type, which includes a well known model for analyzing possible heating in axisymmetric cold plasmas, we give results on the weak well-posedness of the Dirichlet problem and show that such solutions are characterized by a variational principle. The weak solutions are shown to be saddle points of natural functionals suggested by the divergence form of the PDEs. Moreover, the natural domains of the functionals are the weighted Sobolev spaces to which the solutions belong. In addition, all critical levels will be characterized in terms of global extrema of the functionals restricted to suitable infinite dimensional linear subspaces. These subspaces are defined in terms of a robust spectral theory with weights which is associated to the linear operator and is developed herein. Similar characterizations for the weighted eigenvalue problem and nonlinear variants will also be given. Finally, topological methods are employed to obtain existence results for nonlinear problems including perturbations in the gradient which are then applied to the well-posedness of the linear problem with lower order terms.

  3. A feature of negative hydrogen ion production in the Uramoto-type sheet plasma

    Energy Technology Data Exchange (ETDEWEB)

    Jimbo, Kouichi [Kyoto Univ., Uji (Japan). Inst. of Atomic Energy

    1997-02-01

    It seems that negative hydrogen ions H{sup -} are formed directly from atomic hydrogens H. When the chamber was biased more negative against the anode potential at constant are power, forming a much deeper electrostatic well in the Uramoto-type sheet plasma negative ion source, more negative hydrogen ion currents were extracted. The chamber potential V{sub B} was biased down to -100V in the 150V discharge. The negative ion current J{sup -} was evaluated by the JAERI-probe measurement. J{sup -} increases linearly with the chamber current I{sub B}. The largest J{sup -} value was obtained at absolute value of |V{sub prob,f}|=15V and absolute value of |V{sub B}|=100V; the discharge was not operated for absolute value of |V{sub B}|>100V. We speculate the following collisional (three-body) electron attachment to H as a possible production process for H{sup -}; e+e+H{yields}e+H{sup -}. This process may explain the linear increase of J{sup -} with absolute value of |V{sub prob,f}|. (S.Y.)

  4. Electrical characterization of deep levels in n-type GaAs after hydrogen plasma treatment

    Energy Technology Data Exchange (ETDEWEB)

    Nyamhere, C., E-mail: s210239522@live.nmmu.ac.z [Department of Physics, Nelson Mandela Metropolitan University, PO Box 77000, Port Elizabeth 6031 (South Africa); Botha, J.R.; Venter, A. [Department of Physics, Nelson Mandela Metropolitan University, PO Box 77000, Port Elizabeth 6031 (South Africa)

    2011-05-15

    Deep level transient spectroscopy (DLTS) and Laplace-DLTS (L-DLTS) have been used to investigate defects in an n-type GaAs before and after exposure to a dc hydrogen plasma (hydrogenation). DLTS revealed the presence of three prominent electron traps in the material in the temperature range 20-300 K. However, L-DLTS with its higher resolution enabled the splitting of two narrowly spaced emission rates. Consequently four electron traps at, E{sub C}-0.33 eV, E{sub C}-0.36 eV, E{sub C}-0.38 eV and E{sub C}-0.56 eV were observed in the control sample. Following hydrogenation, all these traps were passivated with a new complex (presumably the M3), emerging at E{sub C}-0.58 eV. Isochronal annealing of the passivated material between 50 and 300 {sup o}C, revealed the emergence of a secondary defect, not previously observed, at E{sub C}-0.37 eV. Finally, the effect of hydrogen passivation is completely reversed upon annealing at 300 {sup o}C, as all the defects originally observed in the reference sample were recovered.

  5. Impact of Ramadan focused education program on hypoglycemic risk and metabolic control for patients with type 2 diabetes

    Science.gov (United States)

    Tourkmani, Ayla M; Hassali, Mohamed Azmi; Alharbi, Turki J; Alkhashan, Hesham I; Alobikan, Aljoharah H; Bakhiet, Ahmed H; Alqahtani, Hala B; Alrasheedy, Alian A; Alawwad, Ahmed D; Mishriky, Adel M; Aljadhey, Hisham

    2016-01-01

    Background Fasting during the month of Ramadan could lead to acute complications and increased hypoglycemic risk of patients with type 2 diabetes. Therefore, diabetes is one of the diseases that need careful observation and special considerations during Ramadan including patients’ education and counseling. Objectives To evaluate the impact of Ramadan focused education program on acute complications and biomedical parameters. Methods A prospective nonrandomized interventional controlled design was run on three phases: before, during, and after Ramadan on 262 type 2 diabetes patients. The intervention group (n=140) received focused individualized diabetic education sessions and antidiabetic medications adjustment before and after Ramadan, while the control group (n=122) received standard diabetic care. A validated hypoglycemia questionnaire was used in both groups to assess the change of the risk. Patients were advised to adjust the dosage and timing of antidiabetic agents according to the recommendations for management of diabetes during Ramadan. Primary outcomes were postintervention change of hypoglycemia score and HbA1c over 6-month follow-up. Data were presented as mean ± standard deviation. HbA1c was expressed in percentage. Results The hypoglycemic scores before, during, and after Ramadan were 14.21±8.50, 6.36±6.17, and 5.44±5.55 in the intervention group, respectively (P<0.001) and 14.01±5.10, 13.46±5.30, and 9.27±4.65 in the control group, respectively (P<0.001). HbA1c levels were 9.79±1.89, 8.26±1.54, and 8.52±1.61 before, during, and after Ramadan in the intervention group, respectively (P<0.001), and 10.04±1.47, 9.54±1.38, and 9.59±1.79 in the control group, respectively (P<0.001). Post-Ramadan reductions of HbA1c and hypoglycemic scores were significantly higher in the intervention group (−13.0% vs −4.5%, P=0.004 for HbA1c and −61.7% vs −33.8%, P<0.001 for hypoglycemic score). Low-density lipoprotein cholesterol improved in the

  6. Impact of Ramadan focused education program on hypoglycemic risk and metabolic control for patients with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Tourkmani AM

    2016-09-01

    Full Text Available Ayla M Tourkmani,1 Mohamed Azmi Hassali,2 Turki J Alharbi,1 Hesham I Alkhashan,1 Aljoharah H Alobikan,1 Ahmed H Bakhiet,1 Hala B Alqahtani,1 Alian A Alrasheedy,3 Ahmed D Alawwad,1 Adel M Mishriky,1 Hisham Aljadhey4 1Family and Community Medicine Department, Prince Sultan Military Medical City, Riyadh, Saudi Arabia; 2Discipline of Social and Administrative Pharmacy, School of Pharmaceutical Sciences, Universiti Sains Malaysia, Penang, Malaysia; 3Department of Pharmacy Practice, Unaizah College of Pharmacy, Qassim University, Qassim Saudi Arabia; 4Medication Safety Research Chair, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia Background: Fasting during the month of Ramadan could lead to acute complications and increased hypoglycemic risk of patients with type 2 diabetes. Therefore, diabetes is one of the diseases that need careful observation and special considerations during Ramadan including patients’ education and counseling. Objectives: To evaluate the impact of Ramadan focused education program on acute complications and biomedical parameters. Methods: A prospective nonrandomized interventional controlled design was run on three phases: before, during, and after Ramadan on 262 type 2 diabetes patients. The intervention group (n=140 received focused individualized diabetic education sessions and antidiabetic medications adjustment before and after Ramadan, while the control group (n=122 received standard diabetic care. A validated hypoglycemia questionnaire was used in both groups to assess the change of the risk. Patients were advised to adjust the dosage and timing of antidiabetic agents according to the recommendations for management of diabetes during Ramadan. Primary outcomes were postintervention change of hypoglycemia score and HbA1c over 6-month follow-up. Data were presented as mean ± standard deviation. HbA1c was expressed in percentage. Results: The hypoglycemic scores before, during, and after Ramadan were 14

  7. Daily rhythms of plasma melatonin, but not plasma leptin or leptin mRNA, vary between lean, obese and type 2 diabetic men.

    Science.gov (United States)

    Mäntele, Simone; Otway, Daniella T; Middleton, Benita; Bretschneider, Silvia; Wright, John; Robertson, M Denise; Skene, Debra J; Johnston, Jonathan D

    2012-01-01

    Melatonin and leptin exhibit daily rhythms that may contribute towards changes in metabolic physiology. It remains unclear, however, whether this rhythmicity is altered in obesity or type 2 diabetes (T2DM). We tested the hypothesis that 24-hour profiles of melatonin, leptin and leptin mRNA are altered by metabolic status in laboratory conditions. Men between 45-65 years old were recruited into lean, obese-non-diabetic or obese-T2DM groups. Volunteers followed strict sleep-wake and dietary regimes for 1 week before the laboratory study. They were then maintained in controlled light-dark conditions, semi-recumbent posture and fed hourly iso-energetic drinks during wake periods. Hourly blood samples were collected for hormone analysis. Subcutaneous adipose biopsies were collected 6-hourly for gene expression analysis. Although there was no effect of subject group on the timing of dim light melatonin onset (DLMO), nocturnal plasma melatonin concentration was significantly higher in obese-non-diabetic subjects compared to weight-matched T2DM subjects (peffect of subject group on absolute plasma leptin concentration and, when expressed relative to an individual's 24-hour mean, plasma leptin showed significant (peffect of time on leptin mRNA expression. Despite an overall effect (peffects of group on leptin mRNA expression. Altered plasma melatonin rhythms in weight-matched T2DM and non-diabetic individuals supports a possible role of melatonin in T2DM aetiology. However, neither obesity nor T2DM changed 24-hour rhythms of plasma leptin relative to cycle mean, or expression of subcutaneous adipose leptin gene expression, compared with lean subjects.

  8. Rapid focused sequencing: a multiplexed assay for simultaneous detection and strain typing of Bacillus anthracis, Francisella tularensis, and Yersinia pestis.

    Directory of Open Access Journals (Sweden)

    Rosemary S Turingan

    Full Text Available BACKGROUND: The intentional release of Bacillus anthracis in the United States in 2001 has heightened concern about the use of pathogenic microorganisms in bioterrorism attacks. Many of the deadliest bacteria, including the Class A Select Agents Bacillus anthracis, Francisella tularensis, and Yersinia pestis, are highly infectious via the pulmonary route when released in aerosolized form. Hence, rapid, sensitive, and reliable methods for detection of these biothreats and characterization of their potential impact on the exposed population are of critical importance to initiate and support rapid military, public health, and clinical responses. METHODOLOGY/PRINCIPAL FINDINGS: We have developed microfluidic multiplexed PCR and sequencing assays based on the simultaneous interrogation of three pathogens per assay and ten loci per pathogen. Microfluidic separation of amplified fluorescently labeled fragments generated characteristic electrophoretic signatures for identification of each agent. The three sets of primers allowed significant strain typing and discrimination from non-pathogenic closely-related species and environmental background strains based on amplicon sizes alone. Furthermore, sequencing of the 10 amplicons per pathogen, termed "Rapid Focused Sequencing," allowed an even greater degree of strain discrimination and, in some cases, can be used to determine virulence. Both amplification and sequencing assays were performed in microfluidic biochips developed for fast thermal cycling and requiring 7 µL per reaction. The 30-plex sequencing assay resulted in genotypic resolution of 84 representative strains belonging to each of the three biothreat species. CONCLUSIONS/SIGNIFICANCE: The microfluidic multiplexed assays allowed identification and strain differentiation of the biothreat agents Bacillus anthracis, Francisella tularensis, and Yersinia pestis and clear discrimination from closely-related species and several environmental

  9. Line focus by the ellipsoidal and hyperbolic mirrors, and the fabrication of the new type`s heated air engine. 1; Daenmenkyo to sokyokumenkyo ni yoru line focus to shingata netsu kuki engine no shisaku. 1

    Energy Technology Data Exchange (ETDEWEB)

    Shishido, K.; Kazimierski, Z.; Shoji, T. [Tohoku Gakuin University, Sendai (Japan). Faculty of Engineering; Sugiura, M. [Tohoku Gakuin Tsutsujigaoka High School, Sendai (Japan); Kobayashi, Y. [Tokyo Special Glass Co. Ltd., Tokyo (Japan)

    1996-10-27

    Line focusing by ellipsoidal and hyperbolic mirrors was devised for solar heat collection, and the new prototype heated air engine is under fabrication based on such focusing. Ellipse is a locus of the point at which the distance from the 2nd focus is equal to that from the circle with the 1st focus as a center and the major axis as a radius. Hyperbola can be also figured under similar geometric conditions. The link mechanism possible to machine quadratic surfaces based on the above principle has been developed. High-precision quadratic surface mirrors can be fabricated by the link mechanism for convergent solar heat power generation, achieving line focusing of light. The new prototype heated air engine is also proposed which is composed of the heating part by line focusing, cylinder, piston and cooling column. This engine is featured by simple function, light weight, compact body, high efficiency and safety, and is under fabrication. Although conventional converging mirrors use all the mirror surface, the new line focusing uses only the upper part of the mirror, and the lower part is turned over for protection of the mirror from strong wind. 9 figs.

  10. Incompatible type A plasma transfusion in patients requiring massive transfusion protocol: Outcomes of an Eastern Association for the Surgery of Trauma multicenter study.

    Science.gov (United States)

    Stevens, W Tait; Morse, Bryan C; Bernard, Andrew; Davenport, Daniel L; Sams, Valerie G; Goodman, Michael D; Dumire, Russell; Carrick, Matthew M; McCarthy, Patrick; Stubbs, James R; Pritts, Timothy A; Dente, Christopher J; Luo-Owen, Xian; Gregory, Jason A; Turay, David; Gomaa, Dina; Quispe, Juan C; Fitzgerald, Caitlin A; Haddad, Nadeem N; Choudhry, Asad; Quesada, Jose F; Zielinski, Martin D

    2017-07-01

    With a relative shortage of type AB plasma, many centers have converted to type A plasma for resuscitation of patients whose blood type is unknown. The goal of this study is to determine outcomes for trauma patients who received incompatible plasma transfusions as part of a massive transfusion protocol (MTP). As part of an Eastern Association for the Surgery of Trauma multi-institutional trial, registry and blood bank data were collected from eight trauma centers for trauma patients (age, ≥ 15 years) receiving emergency release plasma transfusions as part of MTPs from January 2012 to August 2016. Incompatible type A plasma was defined as transfusion to patient blood type B or type AB. Of the 1,536 patients identified, 92% received compatible plasma transfusions and 8% received incompatible type A plasma. Patient characteristics were similar except for greater penetrating injuries (48% vs 36%; p = 0.01) in the incompatible group. In the incompatible group, patients were transfused more plasma units at 4 hours (median, 9 vs. 5; p plasma to patients with blood groups B and AB as part of a MTP does not appear to be associated with significant increases in morbidity or mortality. Therapeutic study, level IV.

  11. Cardiac C-type natriuretic peptide gene expression and plasma concentrations in neonatal piglets

    DEFF Research Database (Denmark)

    Hansen, Lasse; Smith, Julie; Goetze, Jens P

    2014-01-01

    in plasma and cardiac tissue extracts were quantified by a porcine-specific radioimmunoassay. RESULTS: Cardiac CNP mRNA contents (n=24) were low compared to sites of known expression, where porcine seminal vesicle CNP mRNA contents were 200-fold higher. In addition, plasma proCNP concentrations...

  12. Plasma cholesteryl ester transfer is a determinant of intima-media thickness in type 2 diabetic and nondiabetic subjects : Role of CETP and triglycerides

    NARCIS (Netherlands)

    de Vries, R; Perton, FG; Dallinga-Thie, GM; van Roon, AM; Wolffenbuttel, BHR; van Tol, A; Dullaart, RPF

    2005-01-01

    We tested whether carotid artery intima-media thickness (IMT) is associated with plasma cholesteryl ester transfer (CET) and/or the plasma cholesteryl ester transfer protein (CETP) concentration in type 2 diabetic and control subjects. In 87 male and female subjects with type 2 diabetes (nonsmokers,

  13. A cross-sectional survey on prevalence and risk factors for abnormal plasma liver enzymes in overweight or obese patients with type 2 diabetes mellitus

    Institute of Scientific and Technical Information of China (English)

    王娇

    2014-01-01

    Objective To explore the prevalence and risk factors for abnormal plasma liver enzymes in patients with type 2diabetes mellitus.Methods Overweight or obese patients with type 2 diabetes were recruited from 60 tertiary and secondary hospitals in Guangdong Province between August 2011 and March 2012.The abnormal plasma liver

  14. Plasma cholesteryl ester transfer is a determinant of intima-media thickness in type 2 diabetic and nondiabetic subjects : Role of CETP and triglycerides

    NARCIS (Netherlands)

    de Vries, R; Perton, FG; Dallinga-Thie, GM; van Roon, AM; Wolffenbuttel, BHR; van Tol, A; Dullaart, RPF

    2005-01-01

    We tested whether carotid artery intima-media thickness (IMT) is associated with plasma cholesteryl ester transfer (CET) and/or the plasma cholesteryl ester transfer protein (CETP) concentration in type 2 diabetic and control subjects. In 87 male and female subjects with type 2 diabetes (nonsmokers,

  15. Plasma cholesteryl ester transfer is a determinant of intima-media thickness in type 2 diabetic and nondiabetic subjects: Role of CETP and triglycerides

    NARCIS (Netherlands)

    R. de Vries (Rindert); F.G. Perton (Frank G.); G.M. Dallinga-Thie (Geesje); A.M.M. van Roon (Arie); B.H.R. Wolffenbuttel (Bruce); A. van Tol (Arie); R.P.F. Dullaart (Robin)

    2005-01-01

    textabstractWe tested whether carotid artery intima-media thickness (IMT) is associated with plasma cholesteryl ester transfer (CET) and/or the plasma cholesteryl ester transfer protein (CETP) concentration in type 2 diabetic and control subjects. In 87 male and female subjects with type 2 diabetes

  16. Post-heparin plasma lipoprotein lipase, but not hepatic lipase activity, is related to plasma adiponectin in type 2 diabetic patients and healthy subjects

    NARCIS (Netherlands)

    De Vries, R; Wolffenbuttel, BHR; Sluiter, WJ; Van Tol, A; Dullaart, RPF

    2005-01-01

    The aim of this study was to determine the relationships of plasma adiponectin with post-heparin plasma lipoprotein lipase (LPL) and hepatic lipase (HL) activities, and to evaluate whether plasma adiponectin contributes to diabetes-associated dyslipidaemia. Plasma adiponectin, post-heparin plasma

  17. The Effect of Glycemic Control on Plasma Ghrelin and Serum IGF-1 Levels in Type 1 Diabetic Girls

    Directory of Open Access Journals (Sweden)

    Tolga Altuğ Şen

    2009-12-01

    Full Text Available Introduction: The aim of this study was to investigate the effect of glycemic control on plasma ghrelin levels and serum IGF-1 levels in girls with type 1 diabetes. Materials and Method: The study group composed of 32 diabetic girls between the ages of 14.0-20.0 years with Tanner pubertal stage 5; and 15 healthy girls in similar ages with Tanner pubertal stage 5 formed the control group. Diabetic girls were classified as well glycemic controlled (n=18 and poor glycemic controlled (n=14 according to last year’s mean glycosylated hemoglobin levels. All subjects were tested for fasting plasma ghrelin and serum IGF-1 levels. Results: The mean fasting plasma ghrelin levels in girls with well controlled diabetes, in girls wtih poor controlled diabetes and in control group were 483.4±221.9 pg/ml, 310.7±110.2 pg/ml, 471.9±175.0 pg/ml respectively. The mean serum IGF-1 levels in girls with well controlled diabetes was 233.9±59.2 ng/ml, in girls with poor controlled diabetes 183.9±36.7 ng/ml, and in healthy controls 247.3±48.5 ng/ml. Plasma ghrelin levels and serum IGF-1 levels were similar in girls with well controlled diabetes and in the control group, however it was significantly supressed in those with poorly controlled diabetes. Conclusion: The metabolic control may be a determinative factor on plasma ghrelin and serum IGF-1 levels of type 1 diabetics. Plasma ghrelin and serum IGF-1 levels were similar in well glycemic controlled diabetics and control group, while they were suppressed in only poor glycemic controlled diabetics. (Journal of Current Pediatrics 2009; 7: 104-10

  18. Unbound fraction of fluconazole and linezolid in human plasma as determined by ultrafiltration: Impact of membrane type.

    Science.gov (United States)

    Kratzer, Alexander; Kees, Frieder; Dorn, Christoph

    2016-12-15

    Ultrafiltration is a rapid and convenient method to determine the free concentrations of drugs in plasma. Several ultrafiltration devices based on Eppendorf cups are commercially available, but are not validated for such use by the manufacturer. Plasma pH, temperature and relative centrifugal force as well as membrane type can influence the results. In the present work, we developed an ultrafiltration method in order to determine the free concentrations of linezolid or fluconazole, both neutral and moderately lipophilic antiinfective drugs for parenteral as well as oral administration, in plasma of patients. Whereas both substances behaved relatively insensitive in human plasma regarding variations in pH (7.0-8.5), temperature (5-37°C) or relative centrifugal force (1000-10.000xg), losses of linezolid were observed with the Nanosep Omega device due to adsorption onto the polyethersulfone membrane (unbound fraction 75% at 100mg/L and 45% at 0.1mg/L, respectively). No losses were observed with Vivacon which is equipped with a membrane of regenerated cellulose. With fluconazole no differences between Nanosep and Vivacon were observed. Applying standard conditions (pH 7.4/37°C/1000xg/20min), the mean unbound fraction of linezolid in pooled plasma from healthy volunteers was 81.5±2.8% using Vivacon, that of fluconazole was 87.9±3.5% using Nanosep or 89.4±3.3% using Vivacon. The unbound fraction of linezolid was 85.4±3.7% in plasma samples from surgical patients and 92.1±6.2% in ICU patients, respectively. The unbound fraction of fluconazole was 93.9±3.3% in plasma samples from ICU patients.

  19. Plasma C-type natriuretic peptide as a predictor for therapeutic response to metoprolol in children with postural tachycardia syndrome.

    Science.gov (United States)

    Lin, Jing; Han, Zhenhui; Li, Hongxia; Chen, Selena Ying; Li, Xueying; Liu, Ping; Wang, Yuli; Tang, Chaoshu; Du, Junbao; Jin, Hongfang

    2015-01-01

    POTS is a global public-health disease, but predictor for therapeutic response to metoprolol in children with POTS is lacking. This study was designed to investigate predictive value of plasma C-type natriuretic peptide (CNP) in the therapeutic efficacy of metoprolol on postural tachycardia syndrome (POTS) in children. Totally 34 children with POTS and 27 healthy children were included in the study. The head-up test or head-up tilt test was used to check heart rate and blood pressure from supine to upright in subjects. A double antibody (competitive) sandwich immunoluminometric assay was used to detect plasma CNP. Metoprolol was used to treat children with POTS. The difference in plasma concentrations of CNP between responders and non-responders was compared. An ROC curve was used to analyze plasma CNP to predict efficacy of metoprolol on POTS in children. Plasma CNP in children with POTS was significantly higher than that of healthy children [(51.9 ± 31.4) vs. (25.1 ± 19.1) pg/ml, P metoprolol was significantly higher than non-responders [(59.1 ± 33.5) vs. (34.8 ± 16.7) pg/ml, P = 0.037] before treatment. The ROC curve showed that area under the curve was 0.821 (95% CI 0.642-0.999). The cut-off value of plasma CNP > 32.55 pg/ml yielded a sensitivity of 95.8% and specificity of 70% in predicting therapeutic efficacy of metoprolol on POTS children. Plasma CNP might serve as a useful predictor for the therapeutic efficacy of metoprolol on POTS in children.

  20. Plasma clusterin and the CLU Gene rs11136000 variant are associated with mild cognitive impairment in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Rongrong Cai

    2016-07-01

    Full Text Available Objective: Type 2 diabetes mellitus (T2DM is related to an elevated risk of mild cognitive impairment (MCI. Plasma clusterin is reported associated with the early pathology of Alzheimer's disease (AD and longitudinal brain atrophy in subjects with MCI. The rs11136000 single nucleotide polymorphism within the clusterin (CLU gene is also associated with the risk of AD. We aimed to investigate the associations among plasma clusterin, rs11136000 genotype and T2DM-associated MCI. Methods: A total of 231 T2DM patients, including 126 MCI and 105 cognitively healthy controls were enrolled in this study. Demographic parameters were collected and neuropsychological tests were conducted. Plasma clusterin and CLU rs11136000 genotype were examined.Results: Plasma clusterin was significantly higher in MCI patients than in control group (p=0.007. In subjects with MCI, plasma clusterin level was negatively correlated with Montreal cognitive assessment and auditory verbal learning test_delayed recall scores (p=0.027 and p=0.020, respectively. After adjustment for age, educational attainment, and gender, carriers of rs11136000 TT genotype demonstrated reduced risk for MCI compared with the CC genotype carriers (OR=0.158, χ2=4.113, p=0.043. Multivariable regression model showed that educational attainment, duration of diabetes, HDL-c, and plasma clusterin levels are associated with MCI in T2DM patients.Conclusions: Plasma clusterin was associated with MCI and may reflect a protective response in T2DM patients. TT genotype exhibited a reduced risk of MCI compared to CC genotype. Further investigations should be conducted to determine the role of clusterin in cognitive decline.

  1. Daily rhythms of plasma melatonin, but not plasma leptin or leptin mRNA, vary between lean, obese and type 2 diabetic men.

    Directory of Open Access Journals (Sweden)

    Simone Mäntele

    Full Text Available Melatonin and leptin exhibit daily rhythms that may contribute towards changes in metabolic physiology. It remains unclear, however, whether this rhythmicity is altered in obesity or type 2 diabetes (T2DM. We tested the hypothesis that 24-hour profiles of melatonin, leptin and leptin mRNA are altered by metabolic status in laboratory conditions. Men between 45-65 years old were recruited into lean, obese-non-diabetic or obese-T2DM groups. Volunteers followed strict sleep-wake and dietary regimes for 1 week before the laboratory study. They were then maintained in controlled light-dark conditions, semi-recumbent posture and fed hourly iso-energetic drinks during wake periods. Hourly blood samples were collected for hormone analysis. Subcutaneous adipose biopsies were collected 6-hourly for gene expression analysis. Although there was no effect of subject group on the timing of dim light melatonin onset (DLMO, nocturnal plasma melatonin concentration was significantly higher in obese-non-diabetic subjects compared to weight-matched T2DM subjects (p<0.01 and lean controls (p<0.05. Two T2DM subjects failed to produce any detectable melatonin, although did exhibit plasma cortisol rhythms comparable to others in the group. Consistent with the literature, there was a significant (p<0.001 effect of subject group on absolute plasma leptin concentration and, when expressed relative to an individual's 24-hour mean, plasma leptin showed significant (p<0.001 diurnal variation. However, there was no difference in amplitude or timing of leptin rhythms between experimental groups. There was also no significant effect of time on leptin mRNA expression. Despite an overall effect (p<0.05 of experimental group, post-hoc analysis revealed no significant pair-wise effects of group on leptin mRNA expression. Altered plasma melatonin rhythms in weight-matched T2DM and non-diabetic individuals supports a possible role of melatonin in T2DM aetiology. However, neither

  2. Experimental studies of radiation resistance of boron nitride, C2C ceramics Al2O3 and carbon-fiber composites using a PF-1000 plasma-focus device

    Science.gov (United States)

    Gribkov, V. A.; Tuniz, C.; Demina, E. V.; Dubrovsky, A. V.; Pimenov, V. N.; Maslyaev, S. V.; Gaffka, R.; Gryaznevich, M.; Skladnik-Sadowska, E.; Sadowski, M. J.; Miklaszewski, R.; Paduch, M.; Scholz, M.

    2011-04-01

    This paper reports on experiments undertaken to compare the radiation resistance of two types of ceramics, boron nitride (BN) and pure alumina (Al2O3), which are used in a TAEA antenna coil installed in the MAST spherical tokamak. Samples of the investigated materials (bulk BN and a 20 μm film of Al2O3 on Al substrate) were exposed on the axis of the plasma-focus PF-1000 device, which can emit intense streams of hot plasma (v≈107 cm s-1 and Npl≈1018 cm-3) and fast deuteron beams (Ei≈100 keV). The most powerful plasma-ion pulse lasted 0.2-1.0 μs and its intensity decayed in about 100 μs. The irradiation process was diagnosed using fast optical cameras, laser interferometry and optical spectrometry. Experiments were performed at power flux densities equal to 109-1010 W cm-2 or 108-109 W cm-2 during the most powerful stage of the interaction process. The irradiated specimens were investigated by means of optical microscopy and x-ray structure analysis (XRSA). It was shown that at 1010 W cm-2 pulses the Al2O3 coating was completely evaporated, whereas a surface of the BN sample became smoother than in the virgin one. A direct comparison of both samples after the action of 108 W cm-2 pulses demonstrated a wave-like structure (more distinct on Al2O3). Weighing of these samples showed, however, that the evaporation of BN was about two times stronger than that of Al2O3 in spite of the lower irradiation flux; the XRSA showed no evidence of cracking of Al2O3 after these pulses. The insulation properties of Al2O3 did not decline, and the Al2O3 coating may be potentially more beneficial, provided that it is kept below its melting point. Characteristic features of damages of a material based on the carbon-fiber composite with additions of silicium carbide (SiC; 8-40% volumetric) were also investigated. It was found that at q=109 W cm-2, the surface erosion is associated with sputtering and evaporation. The degree of this erosion depends on the fibers' orientation in

  3. Fasting plasma triglyceride concentration: A possible approach to identify increased risk of statin-induced type 2 diabetes.

    Science.gov (United States)

    Sung, Ki-Chul; Reaven, Gerald

    2015-09-01

    To evaluate the hypothesis that measurement of fasting plasma triglyceride concentration identifies individuals at enhanced risk of statin-induced type 2 diabetes mellitus. A retrospective analysis of data collected from routine health examinations in non-diabetic, East Asian individuals (n = 5790) with low-density lipoprotein cholesterol concentrations of ⩾3.4 mmol/L. Subjects were stratified into those with or without a triglyceride concentration of ⩾1.7 mmol/L, and comparisons made of risk factors for type 2 diabetes mellitus. Approximately 40% of men and 20% of women with elevations of both low-density lipoprotein cholesterol and triglyceride concentrations were more insulin resistant (homeostatic model assessment of insulin resistance), associated with higher plasma concentrations of HbA1c, glucose and insulin. Apparently, healthy, non-diabetic East Asian men and women with combined elevations of low-density lipoprotein cholesterol and triglyceride concentrations are glucose intolerant and insulin resistant, and thereby at enhanced risk of type 2 diabetes mellitus. Measurement of plasma triglyceride concentration can identify within a hypercholesterolemic population a subset of individuals at enhanced risk of statin-induced type 2 diabetes mellitus. © The Author(s) 2015.

  4. Urine and plasma metabolites predict the development of diabetic nephropathy in individuals with Type 2 diabetes mellitus.

    Science.gov (United States)

    Pena, M J; Lambers Heerspink, H J; Hellemons, M E; Friedrich, T; Dallmann, G; Lajer, M; Bakker, S J L; Gansevoort, R T; Rossing, P; de Zeeuw, D; Roscioni, S S

    2014-09-01

    Early detection of individuals with Type 2 diabetes mellitus or hypertension at risk for micro- or macroalbuminuria may facilitate prevention and treatment of renal disease. We aimed to discover plasma and urine metabolites that predict the development of micro- or macroalbuminuria. Patients with Type 2 diabetes (n = 90) and hypertension (n = 150) were selected from the community-cohort 'Prevention of REnal and Vascular End-stage Disease' (PREVEND) and the Steno Diabetes Center for this case-control study. Cases transitioned in albuminuria stage (from normo- to microalbuminuria or micro- to macroalbuminuria). Controls, matched for age, gender, and baseline albuminuria stage, remained in normo- or microalbuminuria stage during follow-up. Median follow-up was 2.9 years. Metabolomics were performed on plasma and urine. The predictive performance of a metabolite for albuminuria transition was assessed by the integrated discrimination index. In patients with Type 2 diabetes with normoalbuminuria, no metabolites discriminated cases from controls. In patients with Type 2 diabetes with microalbuminuria, plasma histidine was lower (fold change = 0.87, P = 0.02) and butenoylcarnitine was higher (fold change = 1.17, P = 0.007) in cases vs. controls. In urine, hexose, glutamine and tyrosine were lower in cases vs. controls (fold change = 0.20, P diabetes. Type 2 diabetes-specific plasma and urine metabolites were discovered that predict the development of macroalbuminuria beyond established renal risk markers. These results should be confirmed in a large, prospective cohort. © 2014 The Authors. Diabetic Medicine © 2014 Diabetes UK.

  5. A randomized trial of selenium supplementation and risk of type-2 diabetes, as assessed by plasma adiponectin.

    Directory of Open Access Journals (Sweden)

    Margaret P Rayman

    Full Text Available BACKGROUND: Evidence that selenium affects the risk of type-2 diabetes is conflicting, with observational studies and a few randomized trials showing both lower and higher risk linked to the level of selenium intake and status. We investigated the effect of selenium supplementation on the risk of type-2 diabetes in a population of relatively low selenium status as part of the UK PRECISE (PREvention of Cancer by Intervention with SElenium pilot study. Plasma adiponectin concentration, a recognised independent predictor of type-2 diabetes risk and known to be correlated with circulating selenoprotein P, was the biomarker chosen. METHODS: In a randomized, double-blind, placebo-controlled trial, five hundred and one elderly volunteers were randomly assigned to a six-month intervention with 100, 200 or 300 µg selenium/d as high-selenium or placebo yeast. Adiponectin concentration was measured by ELISA at baseline and after six months of treatment in 473 participants with one or both plasma samples available. RESULTS: Mean (SD plasma selenium concentration was 88.5 ng/g (19.1 at baseline and increased significantly in the selenium-treatment groups. In baseline cross-sectional analyses, the fully adjusted geometric mean of plasma adiponectin was 14% lower (95% CI, 0-27% in the highest than in the lowest quartile of plasma selenium (P for linear trend = 0.04. In analyses across randomized groups, however, selenium supplementation had no effect on adiponectin levels after six months of treatment (P = 0.96. CONCLUSIONS: These findings are reassuring as they did not show a diabetogenic effect of a six-month supplementation with selenium in this sample of elderly individuals of relatively low selenium status.

  6. Association of Plasma Myeloperoxidase Level with Risk of Coronary Artery Disease in Patients with Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Ping Song

    2015-01-01

    Full Text Available Aims. This study aimed to investigate whether the change of plasma myeloperoxidase (MPO level would be associated with the incidence of coronary artery disease (CAD among diabetic patients. Methods. 339 patients with type 2 diabetes mellitus (DM underwent coronary angiography. Of them, 204 cases had CAD and were assigned to CAD group and 135 cases without CAD were assigned to non-CAD group. Results. Compared to non-CAD group, CAD group had higher level of plasma MPO (p<0.01. Multiple linear regression analysis showed that plasma MPO level was correlated with Gensini score. Multiple logistic analysis showed that the odds ratios for CAD across increasing tertiles of MPO level were 1.191 (0.971–1.547 and 1.488 (1.115–2.228 (p=0.048, p=0.009 versus 1st tertile of MPO level, resp. by adjusting for age, sex, and other conventional risk factors for CAD. The subjects were stratified into nine groups according to tertiles of MPO and HbA1c. The odds ratio for CAD was significantly higher in group with highest levels of MPO and HbA1c (OR = 4.08, p<0.01. Conclusion. Plasma MPO level was positively correlated with the degree of coronary artery stenosis in type 2 diabetic patients, and increasing blood glucose might amplify the association between MPO and CAD.

  7. Method for characterization of a spherically bent crystal for K.alpha. X-ray imaging of laser plasmas using a focusing monochromator geometry

    Science.gov (United States)

    Kugland, Nathan; Doeppner, Tilo; Glenzer, Siegfried; Constantin, Carmen; Niemann, Chris; Neumayer, Paul

    2015-04-07

    A method is provided for characterizing spectrometric properties (e.g., peak reflectivity, reflection curve width, and Bragg angle offset) of the K.alpha. emission line reflected narrowly off angle of the direct reflection of a bent crystal and in particular of a spherically bent quartz 200 crystal by analyzing the off-angle x-ray emission from a stronger emission line reflected at angles far from normal incidence. The bent quartz crystal can therefore accurately image argon K.alpha. x-rays at near-normal incidence (Bragg angle of approximately 81 degrees). The method is useful for in-situ calibration of instruments employing the crystal as a grating by first operating the crystal as a high throughput focusing monochromator on the Rowland circle at angles far from normal incidence (Bragg angle approximately 68 degrees) to make a reflection curve with the He-like x-rays such as the He-.alpha. emission line observed from a laser-excited plasma.

  8. Measurement of ion beam angular distribution at different helium gas pressures in a plasma focus device by large-area polycarbonate detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sohrabi, M.; Habibi, M., E-mail: mortezahabibi@gmail.com; Ramezani, V. [Amirkabir University of Technology, Energy Engineering and Physics Department (Iran, Islamic Republic of)

    2017-02-15

    The paper presents an experimental study and analysis of full helium ion density angular distributions in a 4-kJ plasma focus device (PFD) at pressures of 10, 15, 25, and 30 mbar using large-area polycarbonate track detectors (PCTDs) (15-cm etchable diameter) processed by 50-Hz-HV electrochemical etching (ECE). Helium ion track distributions at different pressures, in particular, at the main axis of the PFD are presented. Maximum ion track density of ~4.4 × 10{sup 4} tracks/cm{sup 2} was obtained in the PCTD placed 6 cm from the anode. The ion distributions for all pressures applied are ring-shaped, which is possibly due to the hollow cylindrical copper anode used. The large-area PCTD processed by ECE proves, at the present state-of-theart, a superior method for direct observation and analysis of ion distributions at a glance with minimum efforts and time. Some observations of the ion density distributions at different pressures are reported and discussed.

  9. Optimization of an open-focused microwave oven digestion procedure for determination of metals in diesel oil by inductively coupled plasma optical emission spectrometry.

    Science.gov (United States)

    Sant'Ana, Flavio W; Santelli, Ricardo E; Cassella, Alessandra R; Cassella, Ricardo J

    2007-10-01

    This work reports the optimization of a focused microwave assisted procedure for the wet acid dissolution of diesel oil in order to allow the determination of metals in the samples by inductively coupled plasma optical emission spectrometry (ICP-OES). The dissolution process was monitored by measuring residual carbon content (RCC), also by ICP-OES, in the final solutions obtained after application of digestion program. All experimental work was performed using a commercial sample of diesel oil containing 85.74+/-0.13% of carbon. The initial dissolution program comprised three steps: (i) carbonization with H(2)SO(4); (ii) oxidation with HNO(3) and (iii) final oxidation with H(2)O(2). During work it was verified that the first step played an important role on the dissolution process of this kind of sample. It is therefore, necessary to give a detailed optimization of such step. Employing the optimized conditions it was possible to digest 2.5 g of diesel oil with a 40 min-heating program. At these conditions, residual carbon content was always lower than 5%. Optimized methodology was applied in the determination of metals in three diesel oil samples by ICP-OES. Recovery tests were also performed by adding 10 microg of metals, as organic standards, to the samples before digestion. Recovery percentages always higher than 90% were obtained for the metals of interest (Al, Cu, Fe and Ni), except for Zn, which presented recoveries between 70 and 78%.

  10. Early effects comparison of X-rays delivered at high-dose-rate pulses by a plasma focus device and at low dose rate on human tumour cells.

    Science.gov (United States)

    Virelli, A; Zironi, I; Pasi, F; Ceccolini, E; Nano, R; Facoetti, A; Gavoçi, E; Fiore, M R; Rocchi, F; Mostacci, D; Cucchi, G; Castellani, G; Sumini, M; Orecchia, R

    2015-09-01

    A comparative study has been performed on the effects of high-dose-rate (DR) X-ray beams produced by a plasma focus device (PFMA-3), to exploit its potential medical applications (e.g. radiotherapy), and low-DR X-ray beams produced by a conventional source (XRT). Experiments have been performed at 0.5 and 2 Gy doses on a human glioblastoma cell line (T98G). Cell proliferation rate and potassium outward currents (IK) have been investigated by time lapse imaging and patch clamp recordings. The results showed that PFMA-3 irradiation has a greater capability to reduce the proliferation rate activity with respect to XRT, while it does not affect IK of T98G cells at any of the dose levels tested. XRT irradiation significantly reduces the mean IK amplitude of T98G cells only at 0.5 Gy. This work confirms that the DR, and therefore the source of radiation, is crucial for the planning and optimisation of radiotherapy applications.

  11. Phosphosite mapping of P-type plasma membrane H+-ATPase in homologous and heterologous environments

    DEFF Research Database (Denmark)

    Rudashevskaya, Elena; Ye, Juanying; Jensen, Ole N;

    2012-01-01

    Phosphorylation is an important posttranslational modification of proteins in living cells and primarily serves regulatory purposes. Several methods were employed for isolating phosphopeptides from proteolytically digested plasma membranes of Arabidopsis thaliana. After a mass spectrometric...

  12. Total plasma homocysteine is associated with hypertension in Type I diabetic patients

    DEFF Research Database (Denmark)

    Neugebauer, S; Tarnow, L; Stehouwer, C D

    2002-01-01

    between plasma homocysteine concentrations, methylenetetrahydrofolate reductase gene polymorphism, hypertension, diabetic microvascular and macrovascular complications associated with kidney function. METHODS: Vascular complications, hypertension, methylenetetrahydrofolate reductase genotype (RFLP....../l in patients with normal GFR are not related to vascular complications, but to hypertension (8.6-11.3 micro mol/l: OR 1.9; >11.3 micro mol/l: OR 3.7). The risk for coronary heart disease (CHD) was also enhanced by a plasma homocysteine concentration greater than 11.3 micro mol/l (OR 5.9). Although the T allele...... was an independent determinant of plasma homocysteine, the methylenetetrahydrofolate reductase gene polymorphism was neither associated with diabetic vascular complications nor with hypertension. CONCLUSION/INTERPRETATION: Increased plasma homocysteine concentrations but not the T allele per se, enhance the risk...

  13. Multicusp type electron cyclotron resonance plasma with arrangement of permanent magnets

    Energy Technology Data Exchange (ETDEWEB)

    Amemiya, H.; Maeda, M. [Institute of Physical and Chemical Research, Wako, Saitama (Japan)

    1995-09-01

    ECR (electron cyclotron resonance) plasmas are generated in a multicusp field of 12-pole formed by permanent magnets, where the polarity of the magnetic field at the end sections is reversed to reflect axially drifting electrons as in the mirror field. Furthermore, the radius of multicusp is contracted below the cut-off radius of the waveguide in vacuum. This is effective in increasing the microwave power absorbed in the plasma and the ion density. (author).

  14. Does overnight normalization of plasma glucose by insulin infusion affect assessment of glucose metabolism in Type 2 diabetes?

    DEFF Research Database (Denmark)

    Staehr, P; Højlund, Kurt; Hother-Nielsen, O

    2003-01-01

    AIMS: In order to perform euglycaemic clamp studies in Type 2 diabetic patients, plasma glucose must be reduced to normal levels. This can be done either (i) acutely during the clamp study using high-dose insulin infusion, or (ii) slowly overnight preceding the clamp study using a low-dose insulin...... infusion. We assessed whether the choice of either of these methods to obtain euglycaemia biases subsequent assessment of glucose metabolism and insulin action. METHODS: We studied seven obese Type 2 diabetic patients twice: once with (+ ON) and once without (- ON) prior overnight insulin infusion. Glucose...... turnover rates were quantified by adjusted primed-constant 3-3H-glucose infusions, and insulin action was assessed in 4-h euglycaemic, hyperinsulinaemic (40 mU m-2 min-1) clamp studies using labelled glucose infusates (Hot-GINF). RESULTS: Basal plasma glucose levels (mean +/- sd) were 5.5 +/- 0.5 and 10...

  15. A STUDY ON RELATIONSHIP BETWEEN FASTING PLASMA GLUCOSE, COPPER AND CERULOPLASMIN LEVELS IN TYPE 2 DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    Rangaswamy

    2015-08-01

    Full Text Available INTRODUCTION: Diabetes mellitus (DM is an endocrine disease associated with hyperglycemia characterized by both insulin resistance and defective insulin secretion. Copper a transition metal is present in many tissues like liver, muscle etc., It can oxidize proteins and lipids which lead to increased production of free radical compounds. Ceruloplasmin an alpha 2 globulin is an acute phase copper containing plasma protein synthesized mainly by hepatic parenchymal cells, lymphocytes etc., Reactive oxygen species (ROS/ free radicals production due to hyperglycemia in diabetes mellitus can directly or indirectly alter the integrity and physiological function of cells. Present study was undertaken to study the relationship b etween fasting plasma glucose (FPG, copper and ceruloplasmin in type 2 Diabetes mellitus. MATERIALS AND METHODOLOGY: The study group consisted of a total 100 subjects which included non - diabetic healthy control subjects (n = 50 and type 2 diabetic patien ts (n = 50. Fasting blood samples were collected and analysed for estimation of fasting plasma glucose, serum copper and ceruloplasmin. RESULTS : Results shows increase in levels of copper and FPG (P<0.001 and decrease in ceruloplasmin (P<0.001 in type 2 DM patients compared to healthy controls. CONCLUSION: Our study shows an increase in copper and FPG with decreased levels of ceruloplasmin which may be due to generation of ROS which leads to increased consumption of available antioxidants in the body .

  16. Clinical value of plasma B-type natriuretic peptide assay in pediatric pneumonia accompanied by heart failure

    Science.gov (United States)

    HU, DAN; LIU, YANG; TAO, HUIXIAN; GAO, JINPING

    2015-01-01

    Previous studies have shown that B-type natriuretic peptide (BNP) is useful in differentiating cardiac from pulmonary causes of dyspnea in adults. To date, international guidelines have recommended measurements of circulating BNP as a biomarker for diagnostic and prognostic purposes, as well as therapeutic monitoring, in adults with cardiac diseases, particularly those suffering from acute and chronic heart failure (HF). The aim of the present study was to investigate the differential diagnostic and therapeutic analysis of BNP levels assayed in pediatric pneumonia accompanied by HF. The clinical data of 80 patients with pneumonia, aged 1–3 years, were analyzed. The patients were divided into two groups: Simple pneumonia (46 cases) and pneumonia accompanied by HF (34 cases). All patients underwent two plasma BNP assays: The first one upon admission to the hospital and the second one prior to discharge. The plasma BNP levels of 20 healthy children were used as the negative control. Plasma BNP levels were measured using the Triage® BNP automated immunoassay systems and reagents. Statistical analysis showed that the plasma BNP levels of the patients upon admission were higher in the pneumonia accompanied by HF group compared with those in the simple pneumonia group (750±120 vs. 135±50 pg/ml; P<0.05). In addition, in the pneumonia accompanied by HF group, the plasma BNP levels of the patients were higher upon admission to the hospital than they were prior to discharge (750±120 vs. 115±45 pg/ml; P<0.05); therefore, plasma BNP may comprise a sensitive diagnostic and therapeutic evaluative marker for pediatric patients with pneumonia accompanied by HF. This finding could prove invaluable in the clinical diagnosis and treatment of the disease. PMID:26668612

  17. Inverse Association of Plasma Chromium Levels with Newly Diagnosed Type 2 Diabetes: A Case-Control Study

    Directory of Open Access Journals (Sweden)

    Sijing Chen

    2017-03-01

    Full Text Available Chromium has long been known as an enhancer of insulin action. However, the role of chromium in the development of type 2 diabetes mellitus (T2DM in humans remains controversial. The current study aimed to examine the associations of plasma chromium levels with T2DM and pre-diabetes mellitus (pre-DM. We conducted a case-control study involving 1471 patients with newly diagnosed T2DM, 682 individuals with newly diagnosed pre-DM, and 2290 individuals with normal glucose tolerance in a Chinese population from 2009 to 2014. Plasma chromium was measured by inductively coupled plasma mass spectrometry. Plasma chromium levels were lower in the T2DM and pre-DM groups than in the control group (median: 3.68 μg/L, 3.61 μg/L, 3.97 μg/L, respectively, p < 0.001. After adjustment for potential confounding factors, the odds ratios (95% confidence interval for T2DM across increasing quartiles of plasma chromium levels were 1 (referent, 0.67 (0.55–0.83, 0.64 (0.51–0.79, and 0.58 (0.46–0.73, respectively (p for trend <0.001. The corresponding odds ratios (95% confidence interval for pre-DM were 1 (referent, 0.70 (0.54–0.91, 0.67 (0.52–0.88, and 0.58 (0.43–0.78, respectively (p for trend < 0.001. Our results indicated that plasma chromium concentrations were inversely associated with T2DM and pre-DM in Chinese adults.

  18. Inverse Association of Plasma Chromium Levels with Newly Diagnosed Type 2 Diabetes: A Case-Control Study

    Science.gov (United States)

    Chen, Sijing; Jin, Xiaoling; Shan, Zhilei; Li, Shuzhen; Yin, Jiawei; Sun, Taoping; Luo, Cheng; Yang, Wei; Yao, Ping; Yu, Kaifeng; Zhang, Yan; Cheng, Qian; Cheng, Jinquan; Bao, Wei; Liu, Liegang

    2017-01-01

    Chromium has long been known as an enhancer of insulin action. However, the role of chromium in the development of type 2 diabetes mellitus (T2DM) in humans remains controversial. The current study aimed to examine the associations of plasma chromium levels with T2DM and pre-diabetes mellitus (pre-DM). We conducted a case-control study involving 1471 patients with newly diagnosed T2DM, 682 individuals with newly diagnosed pre-DM, and 2290 individuals with normal glucose tolerance in a Chinese population from 2009 to 2014. Plasma chromium was measured by inductively coupled plasma mass spectrometry. Plasma chromium levels were lower in the T2DM and pre-DM groups than in the control group (median: 3.68 μg/L, 3.61 μg/L, 3.97 μg/L, respectively, p < 0.001). After adjustment for potential confounding factors, the odds ratios (95% confidence interval) for T2DM across increasing quartiles of plasma chromium levels were 1 (referent), 0.67 (0.55–0.83), 0.64 (0.51–0.79), and 0.58 (0.46–0.73), respectively (p for trend <0.001). The corresponding odds ratios (95% confidence interval) for pre-DM were 1 (referent), 0.70 (0.54–0.91), 0.67 (0.52–0.88), and 0.58 (0.43–0.78), respectively (p for trend < 0.001). Our results indicated that plasma chromium concentrations were inversely associated with T2DM and pre-DM in Chinese adults. PMID:28304331

  19. Proportions of several types of plasma and urine microparticles are increased in patients with rheumatoid arthritis with active disease.

    Science.gov (United States)

    Viñuela-Berni, V; Doníz-Padilla, L; Figueroa-Vega, N; Portillo-Salazar, H; Abud-Mendoza, C; Baranda, L; González-Amaro, R

    2015-06-01

    We analysed the proportions of different microparticles (MPs) in plasma from patients with rheumatoid arthritis (RA), and assessed their relationship with disease activity/therapy and their in-vitro effect on proinflammatory cytokine release. Blood and urine samples were obtained from 55 patients with RA (24 untreated and 31 under conventional therapy) and 20 healthy subjects. Fourteen patients with systemic lupus erythematosus (SLE) were also studied. The proportions of CD3(+) , CD14(+) , CD19(+) , CD41(+) and CD62E(+) MPs were determined by flow cytometry analysis. The in-vitro effect of plasma MPs on the release of interleukin (IL)-1, IL-6, IL-17 and tumour necrosis factor (TNF)-α was also analysed. We detected that the proportions of different types of annexin-V(+) MPs were enhanced in plasma (CD3(+) , CD14(+) , CD19(+) , CD41(+) and CD62E(+) MPs) and urine (CD14(+) , CD3(+) and CD19(+) MPs) from RA patients with high disease activity (DAS28 index > 5·1). Accordingly, a significant positive correlation was observed between the levels of MPs and DAS28 score, and these levels diminished significantly at week 4 of immunosuppressive therapy. Finally, MPs isolated from patients with high disease activity induced, in vitro, an enhanced release of IL-1, IL-17 and TNF-α. In SLE, enhanced levels of different types of plasma MPs were also detected, with a tight correlation with disease activity. Our data further support that MPs have a relevant role in the pathogenesis of RA and suggest that the analysis of the proportions of these microvesicles in plasma could be useful to monitor disease activity and therapy response in patients with RA.

  20. Plasma waves

    CERN Document Server

    Swanson, DG

    1989-01-01

    Plasma Waves discusses the basic development and equations for the many aspects of plasma waves. The book is organized into two major parts, examining both linear and nonlinear plasma waves in the eight chapters it encompasses. After briefly discussing the properties and applications of plasma wave, the book goes on examining the wave types in a cold, magnetized plasma and the general forms of the dispersion relation that characterize the waves and label the various types of solutions. Chapters 3 and 4 analyze the acoustic phenomena through the fluid model of plasma and the kinetic effects. Th

  1. High plasma levels of islet amyloid polypeptide in young with new-onset of type 1 diabetes mellitus.

    Directory of Open Access Journals (Sweden)

    Johan F Paulsson

    Full Text Available AIMS/HYPOTHESIS: Islet amyloid polypeptide (IAPP is a beta cell hormone secreted together with insulin upon glucose stimulation. IAPP participates in normal glucose regulation, but IAPP is also known for its ability to misfold and form islet amyloid. Amyloid fibrils form through smaller cell toxic intermediates and deposited amyloid disrupts normal islet architecture. Even though IAPP and amyloid formation are much discussed in type 2 diabetes, our aim was to study the significance of IAPP in type 1 diabetes. RESULTS: Plasma IAPP levels in children and adolescents with newly diagnosed type 1 diabetes (n = 224 were analysed and concentrations exceeding 100 pmol/L (127.2-888.7 pmol/L were found in 11% (25/224. The IAPP increase did not correlate with C-peptide levels. CONCLUSIONS/INTERPRETATION: Plasma levels of IAPP and insulin deviate in a subpopulation of young with newly-diagnosed type 1 diabetes. The determined elevated levels of IAPP might increase the risk for IAPP misfolding and formation of cell toxic amyloid in beta cells. This finding add IAPP-aggregation to the list over putative pathological factors causing type 1 diabetes.

  2. Toluene decomposition by DBD-type plasma combined with metal oxide catalysts supported on ferroelectric materials.

    Science.gov (United States)

    Jeong, Jin Guk; Lee, Hyeong Seok; Kang, Youngjin; Lee, Ki Bong; Yoo, Jung Whan

    2013-06-01

    We investigated toluene decomposition with a single-stage plasma catalytic system operated at atmospheric pressure and working at reduced temperature (T < 75 degrees C), where a synergistic catalyst was integrated on ferroelectric BaTiO3 beads with a high dielectric constant. The catalyst species were characterized by FE-SEM and XPS before and after the experiment. The MnO2/BaTiO3 catalyst showed high stability in igniting plasma during destruction of toluene for 230 hours in a lifetime test.

  3. Plasma Adrenomedullin level in Egyptian children and Adolescents with type 1 diabetes mellitus: relationship to microvascular complications

    Directory of Open Access Journals (Sweden)

    El-Habashy Safinaz A

    2010-02-01

    Full Text Available Abstract Background Adrenomedullin (AM is known to be elevated in different clinical situations including diabetes mellitus (DM, but its potential role in the pathogenesis of vascular complications in diabetic children and adolescents is to be clarified. Hence, the study aimed at assessment of plasma adrenomedullin levels in children and adolescents with type 1 DM and correlation of these levels with metabolic control and diabetic microvascular complications (MVC. Methods The study was performed in the Diabetes Specialized Clinic, Children's Hospital of Ain Shams University in Cairo, Egypt. It included 55 diabetic children and adolescents (mean age 13.93 ± 3.15 years who were subdivided into 40 with no MVC and 15 with MVC. Thirty healthy subjects, age-and sex- matched were included as control group (mean age 12.83 ± 2.82 years. Patients and controls were assessed for glycosylated hemoglobin (HbA1c and plasma adrenomedullin assay using ELISA technique. Results Mean plasma AM levels were significantly increased in patients with and without MVC compared to control group, (110.6 pg/mL, 60.25 pg/mL and 39.2 pg/mL respectively (P Conclusion Higher plasma AM levels in diabetics particularly in those with MVC & its correlation with diabetes duration and metabolic control may reflect the role of AM in diabetic vasculopathy in the pediatric age group.

  4. South Asian individuals at high risk of type 2 diabetes have lower plasma vitamin C levels than white Europeans.

    Science.gov (United States)

    Carter, Patrice; Gray, Laura J; Morris, Danielle H; Davies, Melanie J; Khunti, Kamlesh

    2013-01-01

    Individuals of South Asian origin are at high risk of developing type 2 diabetes; the relationship between this risk and diet remains to be investigated fully. Furthermore, fruit and vegetable intake remains low throughout the world and previous data suggest that intake is associated with risk of diabetes. The aim of this research study was to compare plasma vitamin C concentrations, measured as a biomarker for fruit and vegetable intake, in South Asian and white European individuals. Participants recruited as part of the Let's Prevent Diabetes Study provided samples for the quantification of plasma vitamin C. We compared vitamin C levels by ethnicity using multiple regression, both unadjusted and adjusted for confounders, including glycaemic status. Mean plasma vitamin C was significantly lower in the South Asian participants compared with white European participants (34.5 (sd 19·8) v. 39·9 (sd 22·1) µmol/l, respectively; P ≤ 0·0001). Significantly fewer South Asian individuals consumed five portions of fruit and vegetables per d, as determined by a plasma vitamin C concentration of ≥ 50 µmol/l (23·2 % (n 58) v. 31·4 % (n 558); P = 0·01). Vitamin C reflects habitual fruit and vegetable consumption; thus results suggest that South Asians have lower fruit and vegetable intake. However, it cannot be excluded that vitamin C is utilised differently. Dietary advice specifically targeting the South Asian population should be developed.

  5. Continuous subcutaneous infusion of glucagon-like peptide 1 lowers plasma glucose and reduces appetite in type 2 diabetic patients

    DEFF Research Database (Denmark)

    Toft-Nielsen, M B; Madsbad, Sten; Holst, J J

    1999-01-01

    OBJECTIVE: The gut hormone glucagon-like peptide 1 (GLP-1) has insulinotropic and anorectic effects during intravenous infusion and has been proposed as a new treatment for type 2 diabetes and obesity. The effect of a single subcutaneous injection is brief because of rapid degradation. We therefore...... sought to evaluate the effect of infusion of GLP-1 for 48 h in patients with type 2 diabetes. RESEARCH DESIGN AND METHODS: We infused GLP-1 (2.4 pmol.kg-1.min-1) or saline subcutaneously for 48 h in randomized order in six patients with type 2 diabetes to evaluate the effect on appetite during fixed....... CONCLUSIONS: We conclude that 48-h continuous subcutaneous infusion of GLP-1 in type 2 diabetic patients 1) lowers fasting as well as meal-related plasma glucose, 2) reduces appetite, 3) has no gastrointestinal side effects, and 4) has no negative effect on blood pressure....

  6. A dense plasma focus-based neutron source for a single-shot detection of illicit materials and explosives by a nanosecond neutron pulse

    Energy Technology Data Exchange (ETDEWEB)

    Gribkov, V A; Latyshev, S V [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Miklaszewski, R A; Chernyshova, M [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Drozdowicz, K; Wiacek, U [Institute of Nuclear Physics, Krakow (Poland); Tomaszewski, K [ACS Ltd, Warsaw (Poland); Lemeshko, B D [N L Dukhov All-Russian Institute of Automation, Moscow (Russian Federation)], E-mail: gribkovv@yahoo.com

    2010-03-15

    Recent progress in a single-pulse Nanosecond Impulse Neutron Investigation System (NINIS) intended for interrogation of hidden objects by means of measuring elastically scattered neutrons is presented in this paper. The method uses very bright neutron pulses having duration of the order of 10 ns only, which are generated by dense plasma focus (DPF) devices filled with pure deuterium or DT mixture as a working gas. The small size occupied by the neutron bunch in space, number of neutrons per pulse and mono-chromaticity ({delta}E/E{approx}1%) of the neutron spectrum provides the opportunity to use a time-of-flight (TOF) technique with flying bases of about a few metres. In our researches we used DPF devices having bank energy in the range 2-7 kJ. The devices generate a neutron yield of the level of 10{sup 8}-10{sup 9} 2.45 MeV and 10{sup 10}-10{sup 11} 14 MeV neutrons per pulse with pulse duration {approx}10-20 ns. TOF base in the tests was 2.2-18.5 m. We have demonstrated the possibility of registering of neutrons scattered by the substances under investigation-1 litre bottles with methanol (CH{sub 3}OH), phosphoric (H{sub 2}PO{sub 4}) and nitric (HNO{sub 3}) acids as well as a long object-a 1 m gas tank filled with deuterium at high pressure. It is shown that the above mentioned short TOF bases and relatively low neutron yields are enough to distinguish different elements' nuclei composing the substance under interrogation and to characterize the geometry of lengthy objects in some cases. The wavelet technique was employed to 'clean' the experimental data registered. The advantages and restrictions of the proposed and tested NINIS technique in comparison with other methods are discussed.

  7. A dense plasma focus-based neutron source for a single-shot detection of illicit materials and explosives by a nanosecond neutron pulse

    Science.gov (United States)

    Gribkov, V. A.; Latyshev, S. V.; Miklaszewski, R. A.; Chernyshova, M.; Drozdowicz, K.; Wiącek, U.; Tomaszewski, K.; Lemeshko, B. D.

    2010-03-01

    Recent progress in a single-pulse Nanosecond Impulse Neutron Investigation System (NINIS) intended for interrogation of hidden objects by means of measuring elastically scattered neutrons is presented in this paper. The method uses very bright neutron pulses having duration of the order of 10 ns only, which are generated by dense plasma focus (DPF) devices filled with pure deuterium or DT mixture as a working gas. The small size occupied by the neutron bunch in space, number of neutrons per pulse and mono-chromaticity (ΔE/E~1%) of the neutron spectrum provides the opportunity to use a time-of-flight (TOF) technique with flying bases of about a few metres. In our researches we used DPF devices having bank energy in the range 2-7 kJ. The devices generate a neutron yield of the level of 108-109 2.45 MeV and 1010-1011 14 MeV neutrons per pulse with pulse duration ~10-20 ns. TOF base in the tests was 2.2-18.5 m. We have demonstrated the possibility of registering of neutrons scattered by the substances under investigation—1 litre bottles with methanol (CH3OH), phosphoric (H2PO4) and nitric (HNO3) acids as well as a long object—a 1 m gas tank filled with deuterium at high pressure. It is shown that the above mentioned short TOF bases and relatively low neutron yields are enough to distinguish different elements' nuclei composing the substance under interrogation and to characterize the geometry of lengthy objects in some cases. The wavelet technique was employed to 'clean' the experimental data registered. The advantages and restrictions of the proposed and tested NINIS technique in comparison with other methods are discussed.

  8. Erythrocyte caspase-3 activation and oxidative imbalance in erythrocytes and in plasma of type 2 diabetic patients.

    Science.gov (United States)

    Maellaro, Emilia; Leoncini, Silvia; Moretti, Daniele; Del Bello, Barbara; Tanganelli, Italo; De Felice, Claudio; Ciccoli, Lucia

    2013-08-01

    An increased oxidative stress and a decreased life span of erythrocytes (RBCs) are reported in patients with diabetes. Aim of this study was to assess in RBCs from patients with type 2 diabetes whether downstream effector mechanisms of apoptosis, such as activation of caspase-3, is operative, and whether an iron-related oxidative imbalance, occurring inside RBCs and in plasma, could be involved in caspase-3 activation. In 26 patients with type 2 diabetes and in 12 healthy subjects, oxidative stress was evaluated by means of different markers; non-protein-bound iron, methemoglobin and glutathione were determined in RBCs, and non-protein-bound iron was also determined in plasma. Erythrocyte caspase-3 activation was evaluated by an immunosorbent enzyme assay. Arterial hypertension, demographic and standard biochemical data were also evaluated. The results show, for the first time, that type 2 diabetic RBCs put into motion caspase-3 activation, which is significantly higher than in control RBCs. Such an effector mechanism of "eryptosis" was positively correlated to blood glucose levels and to the increased plasma NPBI level. Caspase-3 activation was also positively correlated to occurrence of arterial hypertension. The results suggest that an extracellular oxidative milieu can be responsible for erythrocyte caspase-3 activation in patients with type 2 diabetes. In turn, caspase-3 activation can be envisaged as a novel mechanism which, by impairing the maintenance of erythrocyte shape and function, might contribute to the shortened life span of RBCs from patients with type 2 diabetes and to hemorheological disorders observed in these patients.

  9. Increased cholesterol efflux from cultured fibroblasts to plasma from hypertriglyceridemic type 2 diabetic patients: roles of pre beta-HDL, phospholipid transfer protein and cholesterol esterification.

    Science.gov (United States)

    de Vries, R; Groen, A K; Perton, F G; Dallinga-Thie, G M; van Wijland, M J A; Dikkeschei, L D; Wolffenbuttel, B H R; van Tol, A; Dullaart, R P F

    2008-02-01

    We tested whether hypertriglyceridemia associated with type 2 diabetes mellitus is accompanied by alterations in pre beta-HDL, which are considered to be initial acceptors of cell-derived cholesterol, and by changes in the ability of plasma to promote cellular cholesterol efflux. In 28 hypertriglyceridemic and 56 normotriglyceridemic type 2 diabetic patients, and in 56 control subjects, we determined plasma lipids, HDL cholesterol and phospholipids, plasma pre beta-HDL and pre beta-HDL formation, phospholipid transfer protein (PLTP) activity, plasma cholesterol esterification (EST) and cholesteryl ester transfer (CET) and the ability of plasma to stimulate cholesterol efflux out of cultured human fibroblasts. HDL cholesterol and HDL phospholipids were lower, whereas plasma PLTP activity, EST and CET were higher in hypertriglyceridemic diabetic patients than in the other groups. Pre beta-HDL levels and pre beta-HDL formation were unaltered, although the relative amount of pre beta-HDL (expressed as % of total plasma apo A-I) was increased in hypertriglyeridemic diabetic patients. Cellular cholesterol efflux to plasma from hypertriglyceridemic diabetic patients was increased compared to efflux to normotriglyceridemic diabetic and control plasma, but efflux to normotriglyceridemic diabetic and control plasma did not differ. Multiple linear regression analysis demonstrated that cellular cholesterol efflux to plasma was positively and independently related to pre beta-HDL formation, PLTP activity and EST (multiple r=0.48), but not to the diabetic state. In conclusion, cholesterol efflux from fibroblasts to normotriglyceridemic diabetic plasma is unchanged. Efflux to hypertriglyceridemic diabetic plasma is enhanced, in association with increased plasma PLTP activity and cholesterol esterification. Unaltered pre beta-HDL formation in diabetic hypertriglyceridemia, despite low apo A-I, could contribute to maintenance of cholesterol efflux.

  10. Plasma concentrations of generic lopinavir/ritonavir in HIV type-1-infected individuals.

    NARCIS (Netherlands)

    Lugt, J. van der; Lange, J.; Avihingsanon, A.; Ananworanich, J.; Sealoo, S.; Burger, D.M.; Gorowara, M.; Phanuphak, P.; Ruxrungtham, K.

    2009-01-01

    BACKGROUND: Generic drugs can contribute to access to treatment for HIV-infected patients. However quality and safety remains an issue of concern. Therefore, we evaluated minimal plasma concentrations and short-term safety of a generic lopinavir/ritonavir 200/50 mg tablet formulation. METHODS: In a

  11. Plasminogen activator inhibitor-type I: its plasma determinants and relation with cardiovascular risk

    NARCIS (Netherlands)

    Hoekstra, T.; Geleijnse, J.M.; Schouten, E.G.; Kluft, C.

    2004-01-01

    The habitual level of PAI-1 is influenced by many factors, of which obesity and insulin resistance are the most important. It is possible to reduce plasma PAI-1 by changes in life style, e.g. weight reduction and physical activity. Data on potential interactions between environmental and metabolic v

  12. Mutagenicity and Immune Toxicity of Emulsion-type Sausage Cured with Plasma-treated Water.

    Science.gov (United States)

    Kim, Hyun-Joo; Sung, Nak-Yun; Yong, Hae In; Kim, Hanwool; Lim, Younggap; Ko, Kwang Hyun; Yun, Cheol-Heui; Jo, Cheorun

    2016-01-01

    Cold plasma has been developed to reduce microbial contamination and to improve safety of food and medical products. In addition, the technology can be used in the manufacture of sausages without addition of nitrite. To be applied in food industry commercially, the new technology should be safe and efficient. However, toxicological test of plasma-treated food is limited. Therefore, the purpose of this study was to determine the mutagenicity and immune toxicity of the meat products cured with plasma-treated water (PTW) as a nitrite source. Emulsion sausages were prepared with no nitrite (control), sodium nitrite (SCS), and PTW (SCP). For a mutagenicity test, the Ames test was performed with the sausage samples. For immune toxicity test, 8-wk-old female Balb/c mice were given free access to the sausages in order to evaluate the tumor necrosis factor (TNF)-α level. As a result, no mutagenicity was detected in the sausages by the Ames test. The serum TNF-α values were less than 10 pg/mL in mice after feeding control and treated samples for 32 d, indicating that no inflammatory response was occurred by feeding the sausages made by PTW. Therefore, the present study opens the possibility of using plasma-treated water as a nitrite source without any toxicity.

  13. Cardiac C-type natriuretic peptide gene expression and plasma concentrations in neonatal piglets

    DEFF Research Database (Denmark)

    Hansen, Lasse H; Smith, Julie; Goetze, Jens Peter

    2014-01-01

    and cardiac tissue extracts were quantified by a porcine-specific radioimmunoassay. RESULTS: Cardiac CNP mRNA contents (n=24) were low compared to sites of known expression, where porcine seminal vesicle CNP mRNA contents were 200-fold higher. In addition, plasma proCNP concentrations in the newborn piglets...

  14. Plasma alpha-defensin is associated with cardiovascular morbidity and mortality in type 1 diabetic patients

    DEFF Research Database (Denmark)

    Joseph, G.; Tarnow, L.; Astrup, A.S.;

    2008-01-01

    CONTEXT: alpha-Defensins are antimicrobial peptides of the innate immune system. In addition, experimental evidence suggests that alpha-defensins are proatherogenic. OBJECTIVE: The objective of the study was to examine the predictive value of plasma alpha-defensin as a clinical marker...

  15. Chemical compositions and plasma parameters of planetary nebulae with Wolf-Rayet and wels type central stars

    CERN Document Server

    Girard, P; Acker, A

    2006-01-01

    Aims: Chemical compositions and other properties of planetary nebulae around central stars of spectral types [WC], [WO], and wels are compared with those of `normal' central stars, in order to clarify the evolutionary status of each type and their interrelation. Methods: We use plasma diagnostics to derive from optical spectra the plasma parameters and chemical compositions of 48 planetary nebulae. We also reanalyze the published spectra of a sample of 167 non-WR PN. The results as well as the observational data are compared in detail with those from other studies of the objects in common. Results: The central star's spectral type is clearly correlated with electron density, temperature and excitation class of the nebula, [WC] nebulae tend to be smaller than the other types. All this corroborates the view of an evolutionary sequence from cool [WC 11] central stars inside dense, low excitation nebulae towards hot [WO 1] stars with low density, high excitation nebulae. The wels PN, however, appear to be a separ...

  16. Associations of metabolic variables with arterial stiffness in type 2 diabetes mellitus : focus on insulin sensitivity and postprandial triglyceridaemia

    NARCIS (Netherlands)

    van Dijk, RAJM; Bakker, SJL; Scheffer, PG; Heine, RJ; Stehouwer, CDA

    2003-01-01

    Background Type 2 diabetes mellitus is associated with an increased risk of atherothrombotic disease, which may in part be mediated through increased arterial stiffness. We investigated to what extent increased arterial stiffness is associated with cardiovascular risk factors that commonly cluster i

  17. Lommel pulses: an analytic form for localized waves of the focus wave mode type with bandlimited spectrum.

    Science.gov (United States)

    Sheppard, Colin J R; Saari, Peeter

    2008-01-07

    A criticism of the focus wave mode (FWM) solution for localized pulses is that it contains backward propagating components that are difficult to generate in many practical situations. We describe a form of FWM where the strength of the backward propagating components is identically zero and derive special cases where the field can be written in an analytic form. In particular, a free-space version of "backward light" pulse is considered, which moves in the opposite direction with respect to all its spectral constituents.

  18. Plasma lysosphingomyelin demonstrates great potential as a diagnostic biomarker for Niemann-Pick disease type C in a retrospective study.

    Directory of Open Access Journals (Sweden)

    Richard W D Welford

    Full Text Available Niemann-Pick disease type C (NP-C is a devastating, neurovisceral lysosomal storage disorder which is characterised by variable manifestation of visceral signs, progressive neuropsychiatric deterioration and premature death, caused by mutations in the NPC1 and NPC2 genes. Due to the complexity of diagnosis and the availability of an approved therapy in the EU, improved detection of NP-C may have a huge impact on future disease management. At the cellular level dysfunction or deficiency of either the NPC1 or NPC2 protein leads to a complex intracellular endosomal/lysosomal trafficking defect, and organ specific patterns of sphingolipid accumulation. Lysosphingolipids have been shown to be excellent biomarkers of sphingolipidosis in several enzyme deficient lysosomal storage disorders. Additionally, in a recent study the lysosphingolipids, lysosphingomyelin (SPC and glucosylsphingosine (GlcSph, appeared to be elevated in the plasma of three adult NP-C patients. In order to investigate the clinical utility of SPC and GlcSph as diagnostic markers, an in-depth fit for purpose biomarker assay validation for measurement of these biomarkers in plasma by liquid chromatography-tandem mass spectrometry was performed. Plasma SPC and GlcSph are stable and can be measured accurately, precisely and reproducibly. In a retrospective analysis of 57 NP-C patients and 70 control subjects, median plasma SPC and GlcSph were significantly elevated in NP-C by 2.8-fold and 1.4-fold respectively. For miglustat-naïve NP-C patients, aged 2-50 years, the area under the ROC curve was 0.999 for SPC and 0.776 for GlcSph. Plasma GlcSph did not correlate with SPC levels in NP-C patients. The data indicate excellent potential for the use of lysosphingomyelin in NP-C diagnosis, where it could be used to identify NP-C patients for confirmatory genetic testing.

  19. [The profile of plasma non-esterified fatty acids in children with different terms of type 1 diabetes mellitus].

    Science.gov (United States)

    Akmurzina, V A; Petryairina, E E; Saveliev, S V; Selishcheva, A A

    2016-01-01

    Composition and quantitative content of non-esterified fatty acids (NEFA) were investigated in plasma samples of healthy children (12) and children with type 1 diabetes mellitus (DM1) (31) by gas chromatography (GC) after preliminary NEFA solid-phase extraction from plasma lipids. There was a significant (p1) 1.6-fold increase in the total level of NEFA regardless of the disease duration. In the group of DM1 children with the disease period less than 1 year there was an increase in the arachidonic acid (20:4) content (30%) and the oleic acid trans-isomer (18:1) content (82%), and also a decrease in the docosahexaenoic acid (22:6 n3) content (26% ) and the docosapentaenoic acids (22:5 n-6) content (60%). In the group of DM1 children with prolonged course of this disease the altered NEFA levels returned to the normal level.

  20. Association of plasma angiotensin-(1-7 level and left ventricular function in patients with type 2 diabetes mellitus.

    Directory of Open Access Journals (Sweden)

    Pan-Pan Hao

    Full Text Available BACKGROUND: We recently found that overexpression of angiotensin (Ang-converting enzyme 2, which metabolizes Ang-II to Ang-(1-7 and Ang-I to Ang-(1-9, may prevent diabetes-induced left ventricular remodeling and dysfunction in rats. Our objective was to evaluate the association of plasma Ang-(1-7 level and left ventricular function in patients with type 2 diabetes mellitus. METHODOLOGY/PRINCIPAL FINDINGS: We measured the left ventricular ejection fraction (EF, ratio of early to late left ventricular filling velocity (E/A and ratio of early diastolic mitral inflow to annular velocity (E/Ea by ultrasonography in 110 patients with type 2 diabetes mellitus for more than 5 years. Anthropometric and fasting blood values were obtained from medical records. The plasma Ang-(1-7 level in patients with a poor EF (15 was significantly lower than that in patients with E/Ea ≤15. Ang-(1-7 level was negatively correlated with E/Ea and Log-N-terminal pro-B-type natriuretic peptide and positively with EF and E/A. Stepwise multiple regression analysis revealed that Ang-(1-7, hemoglobin A1c and Ang-II levels as well as duration of diabetes predicted EF; Ang-(1-7 level, fasting blood glucose, low-density lipoprotein cholesterol level and duration of diabetes predicted E/A; and Ang-(1-7 and hemoglobin A1c levels predicted E/Ea. CONCLUSIONS/SIGNIFICANCE: Plasma Ang-(1-7 level is independently associated with left ventricular function in patients with type 2 diabetes mellitus and may be a biomarker for assessing cardiac function in such patients.

  1. Plasma pre beta-HDL formation is decreased by atorvastatin treatment in type 2 diabetes mellitus : Role of phospholipid transfer protein

    NARCIS (Netherlands)

    Dallinga-Thie, G. M.; van Tol, A.; Dullaart, R. P. F.

    2009-01-01

    Atorvastatin lowers plasma phospholipid transfer protein (PLTP) activity, which stimulates pre-beta-HDL, generation in vitro. We determined the effect of atorvastatin on pre-beta-HDL formation and its relation with PLTP activity in type 2 diabetes. Methods: Plasma pre-beta-HDL formation as well as p

  2. Type 2 diabetes mellitus is associated with differential effects on plasma cholesteryl ester transfer protein and phospholipid transfer protein activities and concentrations

    NARCIS (Netherlands)

    Dullaart, RPF; De Vries, R; Scheek, L; Borggreve, SE; Van Gent, T; Dallinga-Thie, GM; Ito, M; Nagano, M; Sluiter, WJ; Hattori, H; Van Tol, A

    2004-01-01

    Background: Human plasma contains two lipid transfer proteins, cholesteryl ester transfer protein (CETP) and phospholipid transfer protein (PLTP), which are crucial in reverse cholesterol transport. Methods: Plasma CETP and PLTP activity levels and concentrations in 16 type 2 diabetic patients and 1

  3. Functional and proteomic alterations of plasma high density lipoproteins in type 1 diabetes mellitus.

    Science.gov (United States)

    Manjunatha, Shankarappa; Distelmaier, Klaus; Dasari, Surendra; Carter, Rickey E; Kudva, Yogish C; Nair, K Sreekumaran

    2016-09-01

    Higher HDL-cholesterol (HDL-C) is linked to lower cardiovascular risk but individuals with type 1 diabetes mellitus (T1DM) with normal or high HDL-C have higher cardiovascular events compared to age matched non-diabetic controls (ND). We determined whether altered HDL functions despite having normal HDL-C concentration may explain increased cardiovascular risk in T1DM individuals. We also determined whether irreversible posttranslational modifications (PTMs) of HDL bound proteins occur in T1DM individuals with altered HDL functions. T1DM with poor glycemic control (T1D-PC, HbA1c≥8.5%, n=15) and T1DM with good glycemic control (T1D-GC, HbA1c≤6.6%, n=15) were compared with equal numbers of NDs, ND-PC and ND-GC respectively, matched for age, sex and body mass index (BMI). We measured cholesterol efflux capacity (CEC) of HDL in the serum using J774 macrophages, antioxidant function of HDL as the ability to reverse the oxidative damage of LDL and PON1 activity using commercially available kit. For proteomic analysis, HDL was isolated by density gradient ultracentrifugation and was analyzed by mass spectrometry and shotgun proteomics method. Plasma HDL-C concentrations in both T1DM groups were similar to their ND. However, CEC (%) of T1D-PC (16.9±0.8) and T1D-GC (17.1±1) were lower than their respective ND (17.9±1, p=0.01 and 18.2±1.4, p=0.02). HDL antioxidative function also was lower (p<0.05). The abundance of oxidative PTMs of apolipoproteins involved in CEC and antioxidative functions of HDL were higher in T1D-PC (ApoA4, p=0.041) and T1D-GC (ApoA4, p=0.025 and ApoE, p=0.041) in comparison with ND. Both T1D-PC and T1D-GC groups had higher abundance of amadori modification of ApoD (p=0.002 and p=0.041 respectively) and deamidation modification of ApoA4 was higher in T1D-PC (p=0.025). Compromised functions of HDL particles in T1DM individuals, irrespective of glycemic control, could be explained by higher abundance of irreversible PTMs of HDL proteins. These

  4. Key steps in type III secretion system (T3SS) towards translocon assembly with potential sensor at plant plasma membrane.

    Science.gov (United States)

    Ji, Hongtao; Dong, Hansong

    2015-09-01

    Many plant- and animal-pathogenic Gram-negative bacteria employ the type III secretion system (T3SS) to translocate effector proteins from bacterial cells into the cytosol of eukaryotic host cells. The effector translocation occurs through an integral component of T3SS, the channel-like translocon, assembled by hydrophilic and hydrophobic proteinaceous translocators in a two-step process. In the first, hydrophilic translocators localize to the tip of a proteinaceous needle in animal pathogens, or a proteinaceous pilus in plant pathogens, and associate with hydrophobic translocators, which insert into host plasma membranes in the second step. However, the pilus needs to penetrate plant cell walls in advance. All hydrophilic translocators so far identified in plant pathogens are characteristic of harpins: T3SS accessory proteins containing a unitary hydrophilic domain or an additional enzymatic domain. Two-domain harpins carrying a pectate lyase domain potentially target plant cell walls and facilitate the penetration of the pectin-rich middle lamella by the bacterial pilus. One-domain harpins target plant plasma membranes and may play a crucial role in translocon assembly, which may also involve contrapuntal associations of hydrophobic translocators. In all cases, sensory components in the target plasma membrane are indispensable for the membrane recognition of translocators and the functionality of the translocon. The conjectural sensors point to membrane lipids and proteins, and a phosphatidic acid and an aquaporin are able to interact with selected harpin-type translocators. Interactions between translocators and their sensors at the target plasma membrane are assumed to be critical for translocon assembly.

  5. Plasma proteomics classifiers improve risk prediction for renal disease in patients with hypertension or type 2 diabetes

    DEFF Research Database (Denmark)

    Pena, Michelle J; Jankowski, Joachim; Heinze, Georg

    2015-01-01

    OBJECTIVE: Micro and macroalbuminuria are strong risk factors for progression of nephropathy in patients with hypertension or type 2 diabetes. Early detection of progression to micro and macroalbuminuria may facilitate prevention and treatment of renal diseases. We aimed to develop plasma...... proteomics classifiers to predict the development of micro or macroalbuminuria in hypertension or type 2 diabetes. METHODS: Patients with hypertension (n = 125) and type 2 diabetes (n = 82) were selected for this case-control study from the Prevention of REnal and Vascular ENd-stage Disease cohort....... RESULTS: In hypertensive patients, the classifier improved risk prediction for transition in albuminuria stage on top of the reference model (C-index from 0.69 to 0.78; P diabetes, the classifier improved risk prediction for transition from micro to macroalbuminuria (C-index from 0...

  6. E→H mode transition density and power in two types of inductively coupled plasma configuration

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jian; Du, Yin-chang; Zhang, Xiao; Zheng, Zhe; Liu, Yu; Xu, Liang; Wang, Pi; Cao, Jin-xiang, E-mail: jxcao@ustc.edu.cn [Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2014-07-15

    E → H transition power and density were investigated at various argon pressures in inductively coupled plasma (ICP) in a cylindrical interlaid chamber. The transition power versus the pressure shows a minimum transition power at 4 Pa (ν/ω=1) for argon. Then the transition density hardly changes at low pressures (ν/ω≪1), but it increases clearly when argon pressure exceeds an appropriate value. In addition, both the transition power and transition density are lower in the re-entrant configuration of ICP compared with that in the cylindrical configuration of ICP. The result may be caused from the decrease of stochastic heating in the re-entrant configuration of ICP. This work is useful to understand E → H mode transition and control the transition points in real plasma processes.

  7. Negative ion beam formation using thermal contact ionization type plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Fukuura, Yoshiyuki; Murakami, Kazutugu; Masuoka, Toshio; Katsumata, Itsuo [Osaka City Univ. (Japan). Faculty of Engineering

    1997-02-01

    The small ion sources utilizing thermal ionization have been already developed, and at present, in order to increase ion yield, that being developed to the cylindrical plasma prototype having the inner surface of a Re foil cylinder as the ionization surface, and stably functioning at 3,000 K has been developed, and by using this plasma source, the research on the formation of various ions has been carried out. At present, the research on the formation of Li negative ion beam is carried out. The separation of negative ions from electrons is performed with the locally limited magnetic field using a small iron core electromagnet placed behind the electrostatic accelerating lens system. So for, the formation of about 2 {mu}A at maximum of negative ions was confirmed. It was decided to identify the kinds of ions by time of flight (TOF) process, and the various improvements for this purpose were carried out. The experimental setup, the structure of the plasma source, the circuits for TOF measurement and so on are explained. The experimental results are reported. The problems are the possibility of the formation of alkali metals, the resolution of the time axis of the TOF system and so on. (K.I.)

  8. Decrease of Plasma Glucose by Hibiscus taiwanensis in Type-1-Like Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Lin-Yu Wang

    2013-01-01

    Full Text Available Hibiscus taiwanensis (Malvaceae is widely used as an alternative herb to treat disorders in Taiwan. In the present study, it is used to screen the effect on diabetic hyperglycemia in streptozotocin-induced diabetic rats (STZ-diabetic rats. The extract of Hibiscus taiwanensis showed a significant plasma glucose-lowering action in STZ-diabetic rats. Stems of Hibiscus taiwanensis are more effective than other parts to decrease the plasma glucose in a dose-dependent manner. Oral administration of Hibiscus taiwanensis three times daily for 3 days into STZ-diabetic rats increased the sensitivity to exogenous insulin showing an increase in insulin sensitivity. Moreover, similar repeated administration of Hibiscus taiwanensis for 3 days in STZ-diabetic rats produced a marked reduction of phosphoenolpyruvate carboxykinase (PEPCK expression in liver and an increased expression of glucose transporter subtype 4 (GLUT 4 in skeletal muscle. Taken together, our results suggest that Hibiscus taiwanensis has the ability to lower plasma glucose through an increase in glucose utilization via elevation of skeletal GLUT 4 and decrease of hepatic PEPCK in STZ-diabetic rats.

  9. An update on the treatment of type 1 and type 2 diabetes mellitus: focus on insulin detemir, a long-acting human insulin analog

    Directory of Open Access Journals (Sweden)

    Katarina Raslova

    2010-05-01

    Full Text Available Katarina RaslovaMetabolic Center Ltd and Slovak Medical University, Bratislava, Slovak RepublicAbstract: Basal insulin analogs are used to minimize unpredictable processes of NPH insulin. Modification of the human insulin molecule results in a slower distribution to peripheral target tissues, a longer duration of action with stable concentrations and thus a lower rate of hypoglycemia. Insulin detemir is a basal insulin analog that provides effective therapeutic options for patients with type 1 and type 2 diabetes. For glycemic control, no significant differences were found in HbA1c levels compared with NPH and insulin glargine. It is comparable with insulin glargine in significantly reducing rates of all types of hypoglycemia. Clinical studies have demonstrated that detemir is responsible for significantly lower within-subject variability and no or less weight gain than NPH insulin and glargine. Recent pharmacodynamic studies have shown that detemir can be used once daily in many patients with diabetes. Together with patient-friendly injection devices and dose adjustments, it provides a treatment option with the potential to lower the key barriers of adherence to insulin therapy in type 2 diabetes. Recent guidelines for treatment of type 2 diabetes suggest starting intensive therapy of hyperglycemia at an early stage of diabetes and recommend therapeutic options that provide the possibility of reaching HbA1c goals individually, with a low risk of hypoglycemia or other adverse effects of treatment. The properties of insulin detemir match these requirements.Keywords: insulin analog, insulin detemir, diabetes mellitus, hypoglycemia, within-subject variability

  10. [Initial osteoblast functions on a type of near β-type titanium alloys surfaces modified by the double glow plasma nitriding technology].

    Science.gov (United States)

    Qu, Y H; Li, F L; Wen, K; Wang, W

    2017-02-09

    Objective: To evaluate the adhesion, proliferation, alkaline phosphatase (ALP) activity and the expression of osteogenesis-related genes and osteoprotegerin (OPG)/receptor activator of NF-κB ligand (RANKL) of osteoblast-like cells on a type of near β-type titanium alloys (Ti-5Zr-3Sn-5Mo-15Nb, TLM) surfaces modified by the double glow plasma nitriding technology, and to investigate the effect of the modified surfaces on the initial functions of osteoblast-like cells. Methods: The surfaces of TLM were modified by the double glow plasma nitriding technology. TLM surfaces without modification were used as control. Cell morphology was observed with scanning electron microscopy (SEM). Methyl thiazolyl tetrazolium (MTT) method was used to measure cell proliferation. Cell ALP activity was evaluated by using reagent kits. The mRNA expression of Runt-related transcription factor-2 (RUNX2), typeⅠcollagen alpha 1 chain (COLⅠ α1) and OPG/RANKL were examined by quantitative real-time PCR(qRT-PCR). Results: Four hour following cell alture, cells on modified surfaces extend filopodia and intercellular junction was tight. Three days later, cell proliferation (0.277±0.007) was significantly higher than that in control group (0.249±0.004) (Pplasma nitriding technology has a positive effect on osteoblasts initial adhesion, proliferation and differentiation, and it can also improve expression of OPG mRNA and has an inhibitory effect on RANKL mRNA expression of osteoblasts.

  11. Focus stacking: Comparing commercial top-end set-ups with a semi-automatic low budget approach. A possible solution for mass digitization of type specimens

    Directory of Open Access Journals (Sweden)

    Jonathan Brecko

    2014-12-01

    Full Text Available In this manuscript we present a focus stacking system, composed of commercial photographic equipment. The system is inexpensive compared to high-end commercial focus stacking solutions. We tested this system and compared the results with several different software packages (CombineZP, Auto-Montage, Helicon Focus and Zerene Stacker. We tested our final stacked picture with a picture obtained from two high-end focus stacking solutions: a Leica MZ16A with DFC500 and a Leica Z6APO with DFC290. Zerene Stacker and Helicon Focus both provided satisfactory results. However, Zerene Stacker gives the user more possibilities in terms of control of the software, batch processing and retouching. The outcome of the test on high-end solutions demonstrates that our approach performs better in several ways. The resolution of the tested extended focus pictures is much higher than those from the Leica systems. The flash lighting inside the Ikea closet creates an evenly illuminated picture, without struggling with filters, diffusers, etc. The largest benefit is the price of the set-up which is approximately € 3,000, which is 8 and 10 times less than the LeicaZ6APO and LeicaMZ16A set-up respectively. Overall, this enables institutions to purchase multiple solutions or to start digitising the type collection on a large scale even with a small budget.

  12. Focus stacking: Comparing commercial top-end set-ups with a semi-automatic low budget approach. A possible solution for mass digitization of type specimens.

    Science.gov (United States)

    Brecko, Jonathan; Mathys, Aurore; Dekoninck, Wouter; Leponce, Maurice; VandenSpiegel, Didier; Semal, Patrick

    2014-01-01

    In this manuscript we present a focus stacking system, composed of commercial photographic equipment. The system is inexpensive compared to high-end commercial focus stacking solutions. We tested this system and compared the results with several different software packages (CombineZP, Auto-Montage, Helicon Focus and Zerene Stacker). We tested our final stacked picture with a picture obtained from two high-end focus stacking solutions: a Leica MZ16A with DFC500 and a Leica Z6APO with DFC290. Zerene Stacker and Helicon Focus both provided satisfactory results. However, Zerene Stacker gives the user more possibilities in terms of control of the software, batch processing and retouching. The outcome of the test on high-end solutions demonstrates that our approach performs better in several ways. The resolution of the tested extended focus pictures is much higher than those from the Leica systems. The flash lighting inside the Ikea closet creates an evenly illuminated picture, without struggling with filters, diffusers, etc. The largest benefit is the price of the set-up which is approximately € 3,000, which is 8 and 10 times less than the LeicaZ6APO and LeicaMZ16A set-up respectively. Overall, this enables institutions to purchase multiple solutions or to start digitising the type collection on a large scale even with a small budget.

  13. Plasma connective tissue growth factor is an independent predictor of end-stage renal disease and mortality in type 1 diabetic nephropathy

    DEFF Research Database (Denmark)

    Nguyen, T.Q.; Tarnow, L.; Jorsal, A.

    2008-01-01

    OBJECTIVE: We evaluated the predictive value of baseline plasma connective tissue growth factor (CTGF) in a prospective study of patients with type 1 diabetes. RESEARCH DESIGN AND METHODS: Subjects were 198 type 1 diabetic patients with established diabetic nephropathy and 188 type 1 diabetic...

  14. Plasma connective tissue growth factor is an independent predictor of end-stage renal disease and mortality in type 1 diabetic nephropathy.

    NARCIS (Netherlands)

    Nguyen, T.Q.; Tarnow, L.; Jorsal, A.; Oliver, N.; Roestenberg, P.M.H.; Ito, Y.; Parving, H.H.; Rossing, P.; Nieuwenhoven, FA van; Goldschmeding, R.

    2008-01-01

    OBJECTIVE: We evaluated the predictive value of baseline plasma connective tissue growth factor (CTGF) in a prospective study of patients with type 1 diabetes. RESEARCH DESIGN AND METHODS: Subjects were 198 type 1 diabetic patients with established diabetic nephropathy and 188 type 1 diabetic patien

  15. Combining insulins for optimal blood glucose control in type 1 and 2 diabetes: focus on insulin glulisine

    Directory of Open Access Journals (Sweden)

    Heather Ulrich

    2007-07-01

    lispro or RHI in type 1 or 2 DM and it has been shown to be as safe and effective when used in a continuous subcutaneous insulin infusion (CSII. In summary, insulin glulisine is a safe, effective, and well tolerated rapid-acting insulin analogue across all BMIs and a worthy option for prandial glucose control in type 1 or 2 DM.Keywords: glycemic control, glycosylated hemoglobin A1c (HbA1c, rapid-acting insulin analogues, type 1 diabetes mellitus, type 2 diabetes mellitus, insulin glulisine, body mass index (BMI

  16. Angiotensin II type 1 receptor antagonists in the treatment of hypertension in elderly patients: focus on patient outcomes

    Directory of Open Access Journals (Sweden)

    Artavazd Tadevosyan

    2011-01-01

    Full Text Available Artavazd Tadevosyan1, Eric J MacLaughlin2, Vardan T Karamyan31Departments of Medicine, Montreal Heart Institute and Université de Montréal, Montreal, QC, Canada; 2Department of Pharmacy Practice, 3Department of Pharmaceutical Sciences, School of Pharmacy, Texas Tech University Health Sciences Center, Amarillo, TX, USAAbstract: Hypertension in the elderly is one of the main risk factors of cardiovascular and cerebrovascular diseases. Knowledge regarding the mechanisms of hypertension and specific considerations in managing hypertensive elderly through pharmacological intervention(s is fundamental to improving clinical outcomes. Recent clinical studies in the elderly have provided evidence that angiotensin II type 1 (AT1 receptor antagonists can improve clinical outcomes to a similar or, in certain populations, an even greater extent than other classical arterial blood pressure-lowering agents. This newer class of antihypertensive agents presents several benefits, including potential for improved adherence, excellent tolerability profile with minimal first-dose hypotension, and a low incidence of adverse effects. Thus, AT1 receptor antagonists represent an appropriate option for many elderly patients with hypertension, type 2 diabetes, heart failure, and/or left ventricular dysfunction.Keywords: angiotensin II, ARB, cardiovascular disease, antihypertensive therapy, elderly

  17. Palaeolithic diet decreases fasting plasma leptin concentrations more than a diabetes diet in patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Fontes-Villalba, Maelán; Lindeberg, Staffan; Granfeldt, Yvonne

    2016-01-01

    diabetes. To elucidate the mechanisms behind these effects, we evaluated fasting plasma concentrations of glucagon, insulin, incretins, ghrelin, C-peptide and adipokines from the same study. METHODS: In a randomised, open-label, cross-over study, 13 patients with type 2 diabetes were randomly assigned...... to eat a Palaeolithic diet based on lean meat, fish, fruits, vegetables, root vegetables, eggs and nuts, or a diabetes diet designed in accordance with current diabetes dietary guidelines during two consecutive 3-month periods. The patients were recruited from primary health-care units and included three...

  18. Impaired Increase of Plasma Abscisic Acid in Response to Oral Glucose Load in Type 2 Diabetes and in Gestational Diabetes

    OpenAIRE

    Pietro Ameri; Santina Bruzzone; Elena Mannino; Giovanna Sociali; Gabriella Andraghetti; Annalisa Salis; Monica Laura Ponta; Lucia Briatore; Adami, Giovanni F.; Antonella Ferraiolo; Pier Luigi Venturini; Davide Maggi; Renzo Cordera; Giovanni Murialdo; Elena Zocchi

    2015-01-01

    The plant hormone abscisic acid (ABA) is present and active in humans, regulating glucose homeostasis. In normal glucose tolerant (NGT) human subjects, plasma ABA (ABAp) increases 5-fold after an oral glucose load. The aim of this study was to assess the effect of an oral glucose load on ABAp in type 2 diabetes (T2D) subjects. We chose two sub-groups of patients who underwent an oral glucose load for diagnostic purposes: i) 9 treatment-naive T2D subjects, and ii) 9 pregnant women with gestati...

  19. Opposed circulating plasma levels of endothelin-1 and C-type natriuretic peptide in children with Plasmodium falciparum malaria

    Directory of Open Access Journals (Sweden)

    Issifou Saadou

    2008-12-01

    Full Text Available Abstract Background Molecular mechanisms involved in the pathogenesis of severe Plasmodium falciparum malaria (SM, are not yet fully understood. Both endothelin-1 (ET-1 and C-type natriuretic peptide (CNP are produced by vascular endothelium and act locally as paracrine regulators of vascular tone, ET-1 being a potent vasoconstrictor and CNP having strong vasorelaxant properties. Methods Plasma levels of ET-1 and N-terminal fragments of CNP (NT-proCNP were studied on admission and after 24 hours of treatment, using enzyme-linked-immunosorbent-assay (ELISA technique, in Gabonese children with severe falciparum malaria (SM, n = 50, with uncomplicated malaria (UM, n = 39 and healthy controls (HC, n = 25. Results Compared to HC, malaria patients had significantly higher plasma levels of ET-1 and significantly lower levels of NT-proCNP (p p p = 0.034, whereas UM was not significantly different to HC. In the SM group we found a trend towards lower ET-1 levels compared to UM (p = 0.085. Conclusion In the present study, an imbalance between the vasoconstricitve and vasorelaxant endothelium-derived substances ET-1 and CNP in the plasma of children with falciparum malaria is demonstrated, presumably in favor of vasoconstrictive and pro-inflammatory effects. These results may indicate involvement of ET-1 and CNP in malaria pathogenesis. Furthermore, results of lower ET-1 and CNP levels in SM may reflect endothelial cell damage.

  20. Sphingomyelin-induced inhibition of the plasma membrane calcium ATPase causes neurodegeneration in type A Niemann-Pick disease.

    Science.gov (United States)

    Pérez-Cañamás, A; Benvegnù, S; Rueda, C B; Rábano, A; Satrústegui, J; Ledesma, M D

    2017-05-01

    Niemann-Pick disease type A (NPA) is a rare lysosomal storage disorder characterized by severe neurological alterations that leads to death in childhood. Loss-of-function mutations in the acid sphingomyelinase (ASM) gene cause NPA, and result in the accumulation of sphingomyelin (SM) in lysosomes and plasma membrane of neurons. Using ASM knockout (ASMko) mice as a NPA disease model, we investigated how high SM levels contribute to neural pathology in NPA. We found high levels of oxidative stress both in neurons from these mice and a NPA patient. Impaired activity of the plasma membrane calcium ATPase (PMCA) increases intracellular calcium. SM induces PMCA decreased activity, which causes oxidative stress. Incubating ASMko-cultured neurons in the histone deacetylase inhibitor, SAHA, restores PMCA activity and calcium homeostasis and, consequently, reduces the increased levels of oxidative stress. No recovery occurs when PMCA activity is pharmacologically impaired or genetically inhibited in vitro. Oral administration of SAHA prevents oxidative stress and neurodegeneration, and improves behavioral performance in ASMko mice. These results demonstrate a critical role for plasma membrane SM in neuronal calcium regulation. Thus, we identify changes in PMCA-triggered calcium homeostasis as an upstream mediator for NPA pathology. These findings can stimulate new approaches for pharmacological remediation in a disease with no current clinical treatments.

  1. The association of personal resilience with stress, coping, and diabetes outcomes in adolescents with type 1 diabetes: variable- and person-focused approaches.

    Science.gov (United States)

    Yi-Frazier, Joyce P; Yaptangco, Mona; Semana, Sharla; Buscaino, Emil; Thompson, Valeria; Cochrane, Katie; Tabile, Marissa; Alving, Erin; Rosenberg, Abby R

    2015-09-01

    This study explored the association between personal resilience and distress, coping, and diabetes outcomes in 50 adolescents with type 1 diabetes. Resilience was defined by a factor score derived from validated instruments measuring self-efficacy, optimism, and self-esteem. Variable- and person-focused methodologies were used to explore these associations. Low resilience was associated with higher distress, poor quality of life, and poor glycemic control. Participants with low resilience used more maladaptive coping strategies and were at greatest risk of poor outcomes. Findings suggest that resilience is a promising candidate for interventions designed to reduce distress and improve outcomes for adolescents with type 1 diabetes.

  2. Canagliflozin-current status in the treatment of type 2 diabetes mellitus with focus on clinical trial data

    Science.gov (United States)

    Bhatia, Jagriti; Gamad, Nanda; Bharti, Saurabh; Arya, Dharamvir Singh

    2014-01-01

    Canagliflozin (CFZ) is a member of new class of glucose lowering agents, sodium-glucose co-transporter (SGLT) inhibitors, which got approval by food and drug administration. It has insulin independent action by blocking the transporter protein SGLT2 in the kidneys, resulting in urinary glucose excretion and reduction in blood glucose levels. In clinical trials, CFZ significantly decreased HbA1c level when administered either as monotherapy or as combined therapy with other anti-diabetic drugs. Intriguingly, it showed additional benefits like weight reduction and lowering of blood pressure. The commonly observed side effects were urinary and genital infections. It has exhibited favorable pharmacokinetic and pharmacodynamic profiles even in patients with renal and hepatic damage. Hence, this review purports to outline CFZ as a newer beneficial drug for type 2 diabetes mellitus. PMID:24936262

  3. PARP inhibition ameliorates nephropathy in an animal model of type 2 diabetes: focus on oxidative stress, inflammation, and fibrosis.

    Science.gov (United States)

    Zakaria, Esraa M; El-Maraghy, Nabila N; Ahmed, Ahmed F; Ali, Abdelmonim A; El-Bassossy, Hany M

    2017-02-21

    Poly(ADP-ribose) polymerase (PARP) enzyme contributes to nephropathy, a serious diabetic complication which may lead to end-stage renal disease. The study aims to investigate the effect of PARP over-activation on kidney functions in a type 2 diabetic rat model. The study also tests the therapeutic use of PARP inhibitors in diabetic nephropathy. Type 2 diabetes was induced in adult male rats by high-fructose/high-fat diet and low streptozotocin dose. Then, the PARP inhibitor 4-aminobenzamide (4-AB) was administered daily for 10 weeks. At the end, urine samples were collected to measure urine creatinine, albumin, and total proteins. PARP activity, superoxide dismutase (SOD) activity, and nitrite content were measured in kidney tissue homogenate. Glucose, fructosamine, insulin, and tumor necrosis factor-alpha (TNF-α) were measured in serum. Furthermore, histological studies, collagen deposition, and immunofluorescence of nuclear factor kappa B (NFκB) and transforming growth factor beta1 (TGF-β1) were carried out. PARP enzyme activity was significantly higher in the diabetic group and was significantly reduced by 4-AB administration. Diabetic animals had clear nephropathy indicated by proteinuria and increased albumin excretion rate (AER) which were significantly decreased by PARP inhibition. In addition, PARP inhibition increased creatinine clearance in diabetic animals and reduced renal TGF-β1 and glomerular fibrosis. Moreover, PARP inhibition alleviated the elevated serum TNF-α level, renal NFκB, nitrite, and the decrease in SOD activity in diabetic animals. However, PARP inhibition did not significantly affect neither hyperglycemia nor insulin sensitivity. PARP enzyme inhibition alleviates diabetic nephropathy through decreasing inflammation, oxidative stress, and renal fibrosis.

  4. [Associations of insulin resistance and pancreatic beta-cell function with plasma glucose level in type 2 diabetes].

    Science.gov (United States)

    Nian, Xiaoping; Sun, Gaisheng; Dou, Chunmei; Hou, Hongbo; Fan, Xiuping; Yu, Hongmei; Ma, Ling; He, Bingxian

    2002-06-10

    To investigate the influence of insulin resistance and pancreatic beta-cell function on plasma glucose level in type 2 diabetes so as to provide theoretical basis for reasonable selection of hypoglycemic agents. The plasma non-specific insulin (NSINS), true insulin (TI) and glucose in eight-one type 2 diabetics, 38 males and 43 females, with a mean age of 53 years, were examined 0, 30, 60 and 120 minutes after they had 75 grams of instant noodles. The patients were divided into two groups according to their fasting plasma glucose (FPG): group A (FPG = 8.89 mmol/L). The insulin resistance was evaluated by HOMA-IR, the beta-cell function was evaluated by HOMA-beta formula and the formula deltaI(30)/deltaG(30) = (deltaI(30)-deltaI(0))/(deltaG(30)-deltaG(0)). The insulin area under curve (INSAUC) was evaluated by the formula INSAUC=FINS/2+INS(30)+INS(60)+INS(120)/2. The mean FPG was 6.23 mmol/L in group A and 12.6 mmol/L in group B. PG2H was 11.7 mmol/L in group A and 19.2 mmol/L in group B. The TI levels in group B at 0, 30, 60, 120 min during standard meal test were significantly higher than those in group A: 6.15 +/- 1.06 vs 4.77 +/- 1.06, 9.76 +/- 1.1 vs 5.88 +/- 1.1,14.68 +/- 1.11 vs 6.87 +/- 1.1 and 17.13 +/- 1.12 vs 8.0 +/- 1.1 microU/dl (all P< 0.01). The NSINS showed the same trend. The insulin resistance in group B was 1.5 times that in group A. With the insulin resistance adjusted, the beta cell function in group A was 5 to 6 times that in group B. The INSAUC in group A was 1.66 times larger than that in group B, especially the INSAUC for true insulin (2 times larger). The contribution of insulin resistance and beta cell function to PG2H was half by half in group A and 1:8 in group B. beta cell function calculated by insulin (Homa-beta) explained 41% of the plasma glucose changes in group A and 54% of the plasma glucose changes in group B. The contribution of insulin deficiency to plasma glocose was 3.3.times that of insulin resistance in group A and was 9

  5. Improved plasma accelerator

    Science.gov (United States)

    Cheng, D. Y.

    1971-01-01

    Converging, coaxial accelerator electrode configuration operates in vacuum as plasma gun. Plasma forms by periodic injections of high pressure gas that is ionized by electrical discharges. Deflagration mode of discharge provides acceleration, and converging contours of plasma gun provide focusing.

  6. SGLT2 inhibitors – an insulin-independent therapeutic approach for treatment of type 2 diabetes: focus on canagliflozin

    Directory of Open Access Journals (Sweden)

    Seufert J

    2015-11-01

    Full Text Available Jochen SeufertDepartment of Endocrinology and Diabetology, Clinic for Internal Medicine II, Freiburg University Hospital, Freiburg, GermanyAbstract: Despite the availability of a great variety of medications, a significant proportion of people with type 2 diabetes mellitus (T2DM are not able to achieve or maintain adequate glycemic control. Beyond improved glucose control, novel treatments would ideally provide a reduction of cardiovascular risk, with a favorable impact on excess weight, and a low intrinsic hypoglycemia risk, as well as a synergistic mechanism of action for broad combination therapy. With the development of sodium glucose cotransporter 2 (SGLT2 inhibitors, an antidiabetic pharmacologic option has recently become available that comes close to meeting these requirements. For the first time, SGLT2 inhibitors offer a therapeutic approach acting directly on the kidneys without requiring insulin secretion or action. Canagliflozin, dapagliflozin, and empagliflozin are the SGLT2 inhibitors approved to date. Taken once a day, these medications can be combined with all other antidiabetic medications including insulin, due to their insulin-independent mechanism of action, with only a minimal risk of hypoglycemia. SGLT2 inhibitors provide additional reductions in body weight and blood pressure due to the therapeutically induced excretion of glucose and sodium through the kidneys. These "concomitant effects" are particularly interesting with regard to the increased cardiovascular risk in T2DM. In many cases, T2DM treatment requires a multidimensional approach where the treatment goals have to be adapted to the individual patient. While there is a consensus on the use of metformin as a first-line drug therapy, various antidiabetics are used for treatment intensification. New mechanisms of action like that of SGLT2 inhibitors such as canagliflozin, which can be used both in early and late stages of diabetes, are a welcome addition to expand

  7. Re-appraisal and extension of the Gratton-Vargas two-dimensional analytical snowplow model of plasma focus - III: Scaling theory for high pressure operation and its implications

    CERN Document Server

    Auluck, S K H

    2016-01-01

    Recent work on the revised Gratton-Vargas model has demonstrated that there are some aspects of Dense Plasma Focus (DPF) which are not sensitive to details of plasma dynamics and are well captured in an oversimplified model assumption which contains very little plasma physics. A hyperbolic conservation law formulation of DPF physics reveals the existence of a velocity threshold related to specific energy of dissociation and ionization, above which, the work done during shock propagation is adequate to ensure dissociation and ionization of the gas being ingested. These developments are utilized to formulate an algorithmic definition of DPF optimization that is valid in a wide range of applications, not limited to neutron emission. A universal scaling theory of DPF design optimization is proposed and illustrated for designing devices working at one or two orders higher pressure of deuterium than the current practice of designs optimized at pressures less than 10 mbar of deuterium. These examples show that the u...

  8. Examining Diet-Related Care Practices Among Adults with Type 2 Diabetes: A Focus on Glycemic Index Choices.

    Science.gov (United States)

    Avedzi, Hayford M; Mathe, Nonsikelelo; Bearman, Stephanie; Storey, Kate; Johnson, Jeffrey A; Johnson, Steven T

    2017-03-01

    We examined self-care dietary practices and usual intakes among adults with Type 2 diabetes in Alberta, Canada, using data from the Healthy Eating and Active Living for Diabetes study. Participants completed a modified Fat/Sugar/Fruit/Vegetable Screener and answered questions about the number of days per week they followed specific diabetes self-care dietary recommendations. Capillary blood samples were collected to assess glycemic control measured by hemoglobin A1c (HbA1c). ANOVA was used to examine differences in dietary self-care, intakes, and glycemic control across categories of days/week of practicing recommended dietary behaviour. Participants (n = 196) were 51% women, mean ± SD age 59.6 ± 8.5 years, with BMI 33.6 ± 6.5 kg/m(2), and diabetes duration of 5.1 ± 6.3 years. Sixteen percent of participants were unfamiliar with low-GI eating and 28% did not include low-GI foods in their diet. Overall, lower mean intake of saturated fat, trans fat, added sugars, higher fibre, and greater GI were each associated with meeting diabetes-related dietary behaviours including: eating ≥5 servings of vegetables and fruit; avoiding processed high fat foods; and replacing high with low-GI foods (P < 0.05). No clear pattern was observed for low-GI eating and HbA1c.

  9. Antihypertensive drugs and erectile dysfunction as seen in spontaneous reports, with focus on angiotensin II type 1 receptor blockers

    Science.gov (United States)

    Ekman, Elisabet; Hägg, Staffan; Sundström, Anders; Werkström, Viktoria

    2010-01-01

    Aim: To describe spontaneously reported cases of erectile dysfunction (ED) in association with angiotensin II type I blockers (ARB) and other antihypertensive drugs. Subjects and methods: All spontaneously reported cases of ED submitted to the Swedish Medical Products Agency (MPA) between 1990 and 2006, where at least one antihypertensive drug was the suspected agent, were scrutinized. Patient demographics, drug treatment and adverse reactions were recorded. Using the Bayesian Confidence Propagation Neural Network (BCPNN) method, the information component (IC) was calculated. Results: Among a total of 225 reports of ED, 59 involved antihypertensive drugs including ARB (9 cases) as suspected agents. A positive IC value was found indicating that ED was reported more often in association with antihypertensive drugs classes, except for angiotensin-converting enzyme inhibitors, compared with all other drugs in the database. Positive dechallenge was reported in 43 cases (72%). Discussion: All classes of major antihypertensive drugs including ARB were implicated as suspected agents in cases of ED. Few risk factors were identified. The relatively high reporting of ED in association with ARB is in contrast with previous studies, suggesting that ARB have neither a positive nor any effect on ED. This discrepancy suggests that further studies are warrnted on this potential adverse reaction to ARB. PMID:21701615

  10. Emerging therapeutic targets in cancer induced bone disease: A focus on the peripheral type 2 cannabinoid receptor.

    Science.gov (United States)

    Marino, Silvia; Idris, Aymen I

    2017-03-05

    Skeletal complications are a common cause of morbidity in patients with primary bone cancer and bone metastases. The type 2 cannabinoid (Cnr2) receptor is implicated in cancer, bone metabolism and pain perception. Emerging data have uncovered the role of Cnr2 in the regulation of tumour-bone cell interactions and suggest that agents that target Cnr2 in the skeleton have potential efficacy in the reduction of skeletal complications associated with cancer. This review aims to provide an overview of findings relating to the role of Cnr2 receptor in the regulation of skeletal tumour growth, osteolysis and bone pain, and highlights the many unanswered questions and unmet needs. This review argues that development and testing of peripherally-acting, tumour-, Cnr2-selective ligands in preclinical models of metastatic cancer will pave the way for future research that will advance our knowledge about the basic mechanism(s) by which the endocannabinoid system regulate cancer metastasis, stimulate the development of a safer cannabis-based therapy for the treatment of cancer and provide policy makers with powerful tools to assess the science and therapeutic potential of cannabinoid-based therapy. Thus, offering the prospect of identifying selective Cnr2 ligands, as novel, alternative to cannabis herbal extracts for the treatment of advanced cancer patients.

  11. Experimental studies of radiation resistance of boron nitride, C2C ceramics Al{sub 2}O{sub 3} and carbon-fiber composites using a PF-1000 plasma-focus device

    Energy Technology Data Exchange (ETDEWEB)

    Gribkov, V A; Demina, E V; Dubrovsky, A V; Pimenov, V N; Maslyaev, S V [Laboratory for Radiation Interaction with Metals, A A Baikov Institute of Metallurgy and Material Science, 119991 Moscow (Russian Federation); Tuniz, C [Multidisciplinary Laboratory, Abdus Salam International Centre for Theoretical Physics, 34014 Trieste (Italy); Gaffka, R; Gryaznevich, M [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Skladnik-Sadowska, E; Sadowski, M J [Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk n. Warsaw (Poland); Miklaszewski, R; Paduch, M; Scholz, M, E-mail: gribkovv@yahoo.com [Dense Magnetized Plasma Division, Institute of Plasma Physics and Laser Microfusion, 01-497 Warsaw (Poland)

    2011-04-15

    This paper reports on experiments undertaken to compare the radiation resistance of two types of ceramics, boron nitride (BN) and pure alumina (Al{sub 2}O{sub 3}), which are used in a TAEA antenna coil installed in the MAST spherical tokamak. Samples of the investigated materials (bulk BN and a 20 {mu}m film of Al{sub 2}O{sub 3} on Al substrate) were exposed on the axis of the plasma-focus PF-1000 device, which can emit intense streams of hot plasma (v{approx}10{sup 7} cm s{sup -1} and N{sub pl}{approx}10{sup 18} cm{sup -3}) and fast deuteron beams (E{sub i}{approx}100 keV). The most powerful plasma-ion pulse lasted 0.2-1.0 {mu}s and its intensity decayed in about 100 {mu}s. The irradiation process was diagnosed using fast optical cameras, laser interferometry and optical spectrometry. Experiments were performed at power flux densities equal to 10{sup 9}-10{sup 10} W cm{sup -2} or 10{sup 8}-10{sup 9} W cm{sup -2} during the most powerful stage of the interaction process. The irradiated specimens were investigated by means of optical microscopy and x-ray structure analysis (XRSA). It was shown that at 10{sup 10} W cm{sup -2} pulses the Al{sub 2}O{sub 3} coating was completely evaporated, whereas a surface of the BN sample became smoother than in the virgin one. A direct comparison of both samples after the action of 10{sup 8} W cm{sup -2} pulses demonstrated a wave-like structure (more distinct on Al{sub 2}O{sub 3}). Weighing of these samples showed, however, that the evaporation of BN was about two times stronger than that of Al{sub 2}O{sub 3} in spite of the lower irradiation flux; the XRSA showed no evidence of cracking of Al{sub 2}O{sub 3} after these pulses. The insulation properties of Al{sub 2}O{sub 3} did not decline, and the Al{sub 2}O{sub 3} coating may be potentially more beneficial, provided that it is kept below its melting point. Characteristic features of damages of a material based on the carbon-fiber composite with additions of silicium carbide (Si

  12. Plasma free amino acid profiling of five types of cancer patients and its application for early detection.

    Directory of Open Access Journals (Sweden)

    Yohei Miyagi

    Full Text Available BACKGROUND: Recently, rapid advances have been made in metabolomics-based, easy-to-use early cancer detection methods using blood samples. Among metabolites, profiling of plasma free amino acids (PFAAs is a promising approach because PFAAs link all organ systems and have important roles in metabolism. Furthermore, PFAA profiles are known to be influenced by specific diseases, including cancers. Therefore, the purpose of the present study was to determine the characteristics of the PFAA profiles in cancer patients and the possibility of using this information for early detection. METHODS AND FINDINGS: Plasma samples were collected from approximately 200 patients from multiple institutes, each diagnosed with one of the following five types of cancer: lung, gastric, colorectal, breast, or prostate cancer. Patients were compared to gender- and age- matched controls also used in this study. The PFAA levels were measured using high-performance liquid chromatography (HPLC-electrospray ionization (ESI-mass spectrometry (MS. Univariate analysis revealed significant differences in the PFAA profiles between the controls and the patients with any of the five types of cancer listed above, even those with asymptomatic early-stage disease. Furthermore, multivariate analysis clearly discriminated the cancer patients from the controls in terms of the area under the receiver-operator characteristics curve (AUC of ROC >0.75 for each cancer, regardless of cancer stage. Because this study was designed as case-control study, further investigations, including model construction and validation using cohorts with larger sample sizes, are necessary to determine the usefulness of PFAA profiling. CONCLUSIONS: These findings suggest that PFAA profiling has great potential for improving cancer screening and diagnosis and understanding disease pathogenesis. PFAA profiles can also be used to determine various disease diagnoses from a single blood sample, which involves a

  13. Identifying low-dimensional dynamics in Type-I edge-localised-mode processes in JET plasmas

    CERN Document Server

    Calderon, F A; Chapman, S C; Webster, A J; Alper, B; Nicol, R M; Contributors, JET EFDA

    2013-01-01

    Edge localised mode (ELM) measurements from reproducibly similar plasmas in the Joint European Torus (JET) tokamak, which differ only in their gas puffing rate, are analysed in terms of the pattern in the sequence of inter-ELM time intervals. It is found that the category of ELM defined empirically as Type I - typically more regular, less frequent, and having larger amplitude than other ELM types - embraces substantially different ELMing processes. By quantifying the structure in the sequence of inter-ELM time intervals using delay time plots, we reveal transitions between distinct phase space dynamics, implying transitions between distinct underlying physical processes. The control parameter for these transitions between these different ELMing processes is the gas puffing rate.

  14. SGLT2 inhibitors – an insulin-independent therapeutic approach for treatment of type 2 diabetes: focus on canagliflozin

    Science.gov (United States)

    Seufert, Jochen

    2015-01-01

    Despite the availability of a great variety of medications, a significant proportion of people with type 2 diabetes mellitus (T2DM) are not able to achieve or maintain adequate glycemic control. Beyond improved glucose control, novel treatments would ideally provide a reduction of cardiovascular risk, with a favorable impact on excess weight, and a low intrinsic hypoglycemia risk, as well as a synergistic mechanism of action for broad combination therapy. With the development of sodium glucose cotransporter 2 (SGLT2) inhibitors, an antidiabetic pharmacologic option has recently become available that comes close to meeting these requirements. For the first time, SGLT2 inhibitors offer a therapeutic approach acting directly on the kidneys without requiring insulin secretion or action. Canagliflozin, dapagliflozin, and empagliflozin are the SGLT2 inhibitors approved to date. Taken once a day, these medications can be combined with all other antidiabetic medications including insulin, due to their insulin-independent mechanism of action, with only a minimal risk of hypoglycemia. SGLT2 inhibitors provide additional reductions in body weight and blood pressure due to the therapeutically induced excretion of glucose and sodium through the kidneys. These “concomitant effects” are particularly interesting with regard to the increased cardiovascular risk in T2DM. In many cases, T2DM treatment requires a multidimensional approach where the treatment goals have to be adapted to the individual patient. While there is a consensus on the use of metformin as a first-line drug therapy, various antidiabetics are used for treatment intensification. New mechanisms of action like that of SGLT2 inhibitors such as canagliflozin, which can be used both in early and late stages of diabetes, are a welcome addition to expand the treatment options for patients at every stage of T2DM. The efficacy and tolerability of canagliflozin have been tested in an extensive clinical trial program

  15. SGLT2 inhibitors - an insulin-independent therapeutic approach for treatment of type 2 diabetes: focus on canagliflozin.

    Science.gov (United States)

    Seufert, Jochen

    2015-01-01

    Despite the availability of a great variety of medications, a significant proportion of people with type 2 diabetes mellitus (T2DM) are not able to achieve or maintain adequate glycemic control. Beyond improved glucose control, novel treatments would ideally provide a reduction of cardiovascular risk, with a favorable impact on excess weight, and a low intrinsic hypoglycemia risk, as well as a synergistic mechanism of action for broad combination therapy. With the development of sodium glucose cotransporter 2 (SGLT2) inhibitors, an antidiabetic pharmacologic option has recently become available that comes close to meeting these requirements. For the first time, SGLT2 inhibitors offer a therapeutic approach acting directly on the kidneys without requiring insulin secretion or action. Canagliflozin, dapagliflozin, and empagliflozin are the SGLT2 inhibitors approved to date. Taken once a day, these medications can be combined with all other antidiabetic medications including insulin, due to their insulin-independent mechanism of action, with only a minimal risk of hypoglycemia. SGLT2 inhibitors provide additional reductions in body weight and blood pressure due to the therapeutically induced excretion of glucose and sodium through the kidneys. These "concomitant effects" are particularly interesting with regard to the increased cardiovascular risk in T2DM. In many cases, T2DM treatment requires a multidimensional approach where the treatment goals have to be adapted to the individual patient. While there is a consensus on the use of metformin as a first-line drug therapy, various antidiabetics are used for treatment intensification. New mechanisms of action like that of SGLT2 inhibitors such as canagliflozin, which can be used both in early and late stages of diabetes, are a welcome addition to expand the treatment options for patients at every stage of T2DM. The efficacy and tolerability of canagliflozin have been tested in an extensive clinical trial program

  16. Circadian pattern of fibrillatory events in non-Brugada-type idiopathic ventricular fibrillation with a focus on J waves.

    Science.gov (United States)

    Aizawa, Yoshiyasu; Sato, Masahito; Ohno, Seiko; Horie, Minoru; Takatsuki, Seiji; Fukuda, Keiichi; Chinushi, Masaomi; Usui, Tatsuya; Aonuma, Kazutaka; Hosaka, Yukio; Haissaguerre, Michel; Aizawa, Yoshifusa

    2014-12-01

    The circadian pattern of ventricular fibrillation (VF) episodes in patients with idiopathic ventricular fibrillation (IVF) is poorly understood. The purpose of this study was to assess the circadian pattern of VF occurrence in patients with IVF. Excluding Brugada syndrome and other primary electrical diseases, the circadian pattern of VF occurrence was determined in 64 patients with IVF. The clinical and electrocardiographic characteristics were compared among patients with nocturnal (midnight to 6:00 AM) VF and nonnocturnal VF in relation to J waves. A J wave was defined as either notching or a slur at the QRS terminal >0.1 mV above the isoelectric line in contiguous leads. The overall distribution pattern of VF occurrence showed 2 peaks at approximately 6:00 AM and around 8:00 PM. Nocturnal VF was observed in 20 patients (31.3%), and J waves were present in 14 of these 20 individuals (70.0%), whereas J waves were less frequent in the 44 nonnocturnal patients with VF: 16 (36.4%) (P = .0117). Among patients with J waves, nocturnal VF was observed in 46.7% with a peak at approximately 4:00 AM. Nocturnal VF was less common in patients without J waves, occurring in only 17.6% (P = .0124). Both the type and location of J waves and the pattern of the ST segment were similar between the nocturnal and nonnocturnal VF groups. J waves were associated with a VF storm and long-term arrhythmia recurrence. In IVF, the presence of J waves may characterize a higher nocturnal incidence of VF and a higher acute and chronic risk of recurrence. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. Continuous subcutaneous infusion of glucagon-like peptide 1 lowers plasma glucose and reduces appetite in type 2 diabetic patients

    DEFF Research Database (Denmark)

    Toft-Nielsen, M B; Madsbad, Sten; Holst, J J

    1999-01-01

    OBJECTIVE: The gut hormone glucagon-like peptide 1 (GLP-1) has insulinotropic and anorectic effects during intravenous infusion and has been proposed as a new treatment for type 2 diabetes and obesity. The effect of a single subcutaneous injection is brief because of rapid degradation. We therefore......, previously shown to lower blood glucose effectively in type 2 diabetic patients. Fasting plasma glucose (day 2) decreased from 14.1 +/- 0.9 (saline) to 12.2 +/- 0.7 mmol/l (GLP-1), P = 0.009, and 24-h mean plasma glucose decreased from 15.4 +/- 1.0 to 13.0 +/- 1.0 mmol/l, P = 0.0009. Fasting and total area...... under the curve for insulin and C-peptide levels were significantly higher during the GLP-1 administration, whereas glucagon levels were unchanged. Neither triglycerides nor free fatty acids were affected. GLP-1 administration decreased hunger and prospective food intake and increased satiety, whereas...

  18. Endothelial dysfunction correlates with plasma fibrinogen and HDL cholesterol in type 2 diabetic patients with coronary artery disease.

    Science.gov (United States)

    Bosevski, M; Borozanov, V; Peovska, I; Georgievska-Ismail, L

    2007-01-01

    Assessment of endothelial dysfunction (ED) in type 2 diabetic patients with coronary artery disease (CAD) and estimation of correlation of ED with metabolic parameters: low HDL, hypertriglyceridemia, obesity, systolic blood pressure and with inflammatory-hemostatic parameters: CRP and fibrinogen. 42 patients (age 60.0 +/- 8.5 years) with diagnosed type 2 diabetes and CAD were randomly included in a cross sectional study. B-mode ultrasound system with a linear transducer 7.5 MHz was used for evaluation of flow mediated vasodilation in brachial artery (FMV). FMV was presented as the percentage increase in brachial artery diameter, within 30 s after limb ischemia, previously provoked by cuff inflation. Percentage value up to 10% was defined as ED. Bivariate linear correlation model presented significant correlation between plasma fibrinogen and FMV percentage, with r -0.47, p HDL HDL (OR 5.16, 95% CI 0.53-60.39) as factors correlated with the presence of endothelial dysfunction. These results presented plasma fibrinogen level and low HDL diabetic patients with coronary artery disease (Tab. 8, Fig. 1, Ref. 25). Full Text (Free, PDF) www.bmj.sk.

  19. Thermoelectric and mechanical properties of melt spun and spark plasma sintered n-type Yb- and Ba-filled skutterudites

    Energy Technology Data Exchange (ETDEWEB)

    Salvador, James R., E-mail: James.salvador@gm.com [General Motors Research and Development Center, 30500 Mound Road, Warren, MI 48090 (United States); Waldo, Richard A.; Wong, Curtis A. [General Motors Research and Development Center, 30500 Mound Road, Warren, MI 48090 (United States); Tessema, Misle [Optimal Inc., 14492 Sheldon Road, Suite 300, Plymouth, MI 48170 (United States); Brown, David N.; Miller, David J. [Molycorp Inc. Research and Development Center, 61 Science Park Road, 01-17 Galen, Singapore 117252 (Singapore); Wang, Hsin; Wereszczak, Andrew A.; Cai, Wei [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States)

    2013-10-01

    Highlights: • N-type double filled skutterudites can be formed by a combination of melt spinning and spark plasma sintering, obviating annealing steps. • The consolidated billets have thermoelectric properties that are comparable to those produced using more time and energy intensive powder metallurgical methods. • We demonstrate that the here described preparation route is scalable to 80 g billets as evidenced by the comparable nature of the transport properties of specimens cuts from large samples to those of smaller lab-scale specimens. -- Abstract: Here we present thermoelectric and mechanical properties of n-type filled-skutterudites produced by a combination of melt spinning of pre-melted charges with subsequent consolidation by spark plasma sintering, a process we refer to as MS-SPS. This combination of processing steps leads to phase-pure n-type filled-skutterudites and obviates more energy and time intensive annealing steps. We show that both the thermoelectric properties and the tensile fracture strength compare favorably to materials made by traditional methods. The process is scalable to at least 80 g billets, such that the transport properties measured on test bars harvested from these larger billets compare favorably to those measured on lab-scale billets (5 g total billet mass). ZT values approaching 1.1 at 750 K were observed in materials made by MS-SPS. In addition, the tensile fracture strength of test bars cut from an 80 g billet is ∼128 MPa at room temperature and decreases with increasing temperature. Fractography of the test bars reveals that the majority failed due to surface and edge flaws with few failures due to volume type flaws. This indicates that the powder metallurgical methods employed to produce these samples is mature.

  20. Studying Coxiella burnetii Type IV Substrates in the Yeast Saccharomyces cerevisiae: Focus on Subcellular Localization and Protein Aggregation.

    Directory of Open Access Journals (Sweden)

    María Rodríguez-Escudero

    Full Text Available Coxiella burnetii is a Gram-negative obligate parasitic bacterium that causes the disease Q-fever in humans. To establish its intracellular niche, it utilizes the Icm/Dot type IVB secretion system (T4BSS to inject protein effectors into the host cell cytoplasm. The host targets of most cognate and candidate T4BSS-translocated effectors remain obscure. We used the yeast Saccharomyces cerevisiae as a model to express and study six C. burnetii effectors, namely AnkA, AnkB, AnkF, CBU0077, CaeA and CaeB, in search for clues about their role in C. burnetii virulence. When ectopically expressed in HeLa cells, these effectors displayed distinct subcellular localizations. Accordingly, GFP fusions of these proteins produced in yeast also decorated distinct compartments, and most of them altered cell growth. CaeA was ubiquitinated both in yeast and mammalian cells and, in S. cerevisiae, accumulated at juxtanuclear quality-control compartments (JUNQs and insoluble protein deposits (IPODs, characteristic of aggregative or misfolded proteins. AnkA, which was not ubiquitinated, accumulated exclusively at the IPOD. CaeA, but not AnkA or the other effectors, caused oxidative damage in yeast. We discuss that CaeA and AnkA behavior in yeast may rather reflect misfolding than recognition of conserved targets in the heterologous system. In contrast, CBU0077 accumulated at vacuolar membranes and abnormal ER extensions, suggesting that it interferes with vesicular traffic, whereas AnkB associated with the yeast nucleolus. Both effectors shared common localization features in HeLa and yeast cells. Our results support the idea that C. burnetii T4BSS effectors manipulate multiple host cell targets, which can be conserved in higher and lower eukaryotic cells. However, the behavior of CaeA and AnkA prompt us to conclude that heterologous protein aggregation and proteostatic stress can be a limitation to be considered when using the yeast model to assess the function of