WorldWideScience

Sample records for plasma exchange

  1. [Plasma exchange in nephrology: Indications and technique].

    Science.gov (United States)

    Ridel, Christophe; Kissling, Sébastien; Mesnard, Laurent; Hertig, Alexandre; Rondeau, Éric

    2017-02-01

    Plasma exchange is a non-selective apheresis technique that can be performed by filtration or centrifugation allowing rapid purification of high molecular weight pathogens. An immunosuppressive treatment is generally associated to reduce the rebound effect of the purified substance. Substitution solutes such as human albumin and macromolecules are needed to compensate for plasma extraction. Compensation by viro-attenuated plasma is reserved solely for the treatment of thrombotic microangiopathies or when there is a risk of bleeding, because this product is very allergenic and expensive. The treatment goal for a plasma exchange session should be between one and one and one-half times the patient's plasma volume estimated at 40 mL/kg body weight. The anticoagulation is best ensured by the citrate. Complications of plasma exchange are quite rare according to the French hemapheresis registry. The level of evidence of efficacy of plasma exchange in nephrology varies from one pathology to another. Main indications of plasma exchange in nephrology are Goodpasture syndrome, antineutrophil cytoplasmic antibody vasculitis when plasma creatinine is greater than 500 μmol/L, and thrombotic microangiopathies. During renal transplantation, plasma exchange may be proposed in the context of human leukocyte antigen (HLA) desensitization protocols or ABO-incompatible graft. After renal transplantation, plasma exchange is indicated as part of the treatment of acute humoral rejection or recurrent focal segmental glomerulosclerosis on the graft. Plasma exchanges are also proposed in the management of cryoglobulinemia or polyarteritis nodosa. Hemodialysis with membranes of very high permeability tends to replace plasma exchange for myeloma nephropathy. The benefit from plasma exchange has not been formally demonstrated for the treatment of severe lupus or antiphospholipid antibody syndrome. There is no indication of plasma exchange in the treatment of scleroderma or nephrogenic

  2. Plasma volume nomograms for use in therapeutic plasma exchange.

    Science.gov (United States)

    Buffaloe, G W; Heineken, F G

    1983-01-01

    Nomograms have been developed for the convenient estimation of the plasma volumes of patients undergoing therapeutic plasma exchange (TPE), based on equations employing height, body weight, and hematocrit. These nomograms are offered as an aid to prescribing continuous-flow TPE procedure exchange volumes.

  3. GEC Plasma Data Exchange Project

    Science.gov (United States)

    Pitchford, L. C.

    2013-08-01

    In 2010 the Gaseous Electronics Conference (GEC), a major international conference for the low temperature plasma science (LTPS) community, initiated the Plasma Data Exchange Project (PDEP). The PDEP is an informal, community-based project that aims to address, at least in part, the well-recognized needs for the community to organize the means of collecting, evaluating and sharing data both for modelling and for interpretation of experiments. The emphasis to date in the PDEP has been on data related to the electron and ion components of these plasmas rather than on the plasma chemistry. At the heart of the PDEP is the open-access website, LXCat [1], developed by researchers at LAPLACE (Laboratoire Plasma et Conversion d'Energie, Toulouse, France). LXCat is a platform for archiving and manipulating collections of data related to electron scattering and transport in cold, neutral gases, organized in databases set-up by individual members or institutions of the LTPS community. At present, 15 databases of electron scattering data, contributed by groups around the world, can be accessed on LXCat. These databases include complete sets of electron cross sections, over an energy range from thermal to nominally 1 keV, for almost 40 ground-state neutral species and partial sets of data for about 30 other neutral, excited and ionized species. 'Complete' implies that all the major electron momentum and energy loss processes are well described in the dataset. Such 'complete' datasets can be used as input to a Boltzmann calculation of the electron energy distribution function (generally non-Maxwellian), and electron transport and rate coefficients can be obtained in pure gases or mixtures by averaging over the distribution function. Online tools enable importing and exporting data, plotting and comparing different sets of data. An online version of the Boltzmann equation solver BOLSIG+ [2] is also available on the LXCat site. Other members of the community have contributed their

  4. Exchange effects in magnetized quantum plasmas

    CERN Document Server

    Trukhanova, Mariya Iv

    2015-01-01

    We apply the many-particle quantum hydrodynamics including the Coulomb exchange interaction to magnetized quantum plasmas. We consider a number of wave phenomenon under influence of the Coulomb exchange interaction. Since the Coulomb exchange interaction affects longitudinal and transverse-longitudinal waves we focus our attention to the Langmuir waves, Trivelpiece-Gould waves, ion-acoustic waves in non-isothermal magnetized plasmas, the dispersion of the longitudinal low-frequency ion-acoustic waves and low-frequencies electromagnetic waves at $T_{e}\\gg T_{i}$ . We obtained the numerical simulation of the dispersion properties of different types of waves.

  5. Exchange effects in a cold plasma

    CERN Document Server

    Ekman, Robin; Brodin, Gert

    2015-01-01

    We have studied the exchange corrections to linear electrostatic wave propagation in a plasma using a quantum kinetic formalism. Specifically we have considered the zero temperature limit. In order to simplify the calculations we have focused on the long wavelength limit, i.e. wavelengths much longer than the de Broglie wavelength. For the case of ion-acoustic waves we have calculated the exchange correction both to the damping rate and the real part of the frequency. For Langmuir waves the frequency shift due to exchange effects is found. Our results are compared with the frequency shifts deduced from commonly used exchange potentials which are computed from density functional theory.

  6. Hyperchloremic metabolic acidosis following plasma exchange during myasthenia gravis crisis.

    Science.gov (United States)

    Ritzenthaler, Thomas; Grousson, Sébastien; Dailler, Frédéric

    2016-10-01

    Therapeutic plasma exchanges are increasingly used, notably during myasthenia gravis crisis. Repeated exchanges may induce severe adverse events. We reported a case of symptomatic hyperchloremic metabolic acidosis following a therapeutic plasma exchange. Analysis of 4% albumin substitution solution revealed a chloride concentration of 145 mmol/L, which could explain this acidosis. Infusion of high volume of 4% albumin during plasma exchanges may produce hyerchloremic metabolic acidosis. Special attention should be paid when repeated plasma exchanges are performed. J. Clin. Apheresis 31:479-480, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  7. Plasma exchange in progressive systemic sclerosis

    Directory of Open Access Journals (Sweden)

    Mohammad Bagher Owlia

    2015-10-01

    Full Text Available Systemic sclerosis (SSc is an autoimmune systemic disease of unknown etiology. Present treatment modalities have limited impact on clinical/ laboratory outcomes. For the first time in our center, we used plasma exchange (PEx in a rather young woman with recent onset but progressive SSc. She is a 39-year-old woman with a recent history of skin stiffness, Raynaud’s phenomenon, nail fold capillary changes and newly diagnosis of SSc presented to us due to worsening her clinical symptoms even after initiation of routine remedies such as low dose oral prednisolone, Ca-channel blockers, azathioprine and pentoxyfylline. After obtaining written consent, interdisciplinary discussion with experts in this field and agreement we started a series of plasma exchange with FFP replacement for her. A dramatic clinical response was observed in respect to Raynaud’s phenomenon, skin stiffness, tendon rub after three sessions of PEx. Her modified Rodnan skin score (MRSS dropped from 36 (before commencement of therapy to 28 in day 4 and 18 in day 20 after 15 sessions of PEx. In conclusion PEx could significantly modify the course of SSc as observed in our case study. Elimination of culprit immune mediators/cytokines/autoantibodies could be the possible mechanism of action of PEx. 

  8. Plasma exchange in the treatment of immune disease.

    Science.gov (United States)

    Branda, R F; Moldow, C F; McCullough, J J; Jacob, H S

    1975-01-01

    Plasma exchange was investigated as an alternative to the use of toxic drugs to remove unwanted antibody. Studies in rabbits immunized with bovine serum albumin demonstrate that exchange transfusion after a primary immunization results in a rebound of antibody to above preexchange levels. However, exchange transfusion seven, 11, or 18 days after secondary immunization results in permanent lowering of antibody levels. Plasma exchange with the continuous flow centrifuge was used in four patients with hematologic diseases. White cell isoantibodies were removed in a septic leukopenic patient, permitting white cell transfusions. Two patients with immune thrombocytopenia were exchanges; one showed prompt and permanent elevation of platelet count, while the other did not improve. A patient with immune hemolytic anemia had stabilization of hemoglobin levels and decreased Coombs reactivity following plasma exchange.

  9. Fine structure of charge exchange lines observed in laboratory plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Ida, K.; Nishimura, S. [National Inst. for Fusion Science, Nagoya (Japan); Kondo, K.

    1997-01-01

    The influence of the fine structure of charge exchange lines appears only at the plasma edge or in the recombining phase where the ion temperature is low enough. The observed spectra in Li III and C VI are consistent with the sum of fine-structure components populated by statistical weights (assuming complete l-mixing) not by direct charge exchange cross sections. Some discrepancy was observed in the intensity ratio of fine-structure components between the observation and calculation for C VI in the recombining phase. The fine-structure of charge exchange lines gives an apparent Doppler shift in plasma rotation velocity measurement using charge exchange spectroscopy. (author)

  10. [Immunoglobulins or plasma exchange? Guillain-Barré syndrome: indications for plasma exchange and immunoglobulins].

    Science.gov (United States)

    Raphaël, J C; Chevret, S; Jars-Guincestre, M C; Chastang, C; Gajdos, P

    1993-01-01

    The effect of plasma exchange (PE) in the Guillain-Barré syndrome (GBS) has been evaluated in 4 randomized clinical trials. A positive effect could be excluded in only one study conducted in Great Britain which included 29 patients. The more powerful studies conducted in Sweden (39 patients), in North America (245 patients) and in France (220 patients) demonstrated that early use of four PEs in patients with a GBS severe enough to require assistance in walking was followed by decreased duration and severity of the acute phase. These conclusions were ratified at a North American consensus conference. More recently, PE has been demonstrated to increase the number of patients who recover normal muscular power after a 1-year follow-up. The French trial also demonstrated that diluted albumin should be preferred over fresh frozen plasma. The number of plasma exchanges and the role of PE in initially benign forms is of great importance and is now under study by a cooperative group in France. The effect of immunoglobulins (IgG) was recently investigated in a randomized trial including 150 patients. In this study, high doses (0.4 g/kg/day for 5 days) were compared with 5 PE administered between days 7 and 14 in children and adults who, at inclusion, were unable to walk. The main result was that the outcome at one month was good with IgG as with PE. Treatment is easier with IgG, and morbidity is lower. Direct costs are similar. If IgG are shown to be as effective as PE, IgG should be given for GBS.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Principles of separation: indications and therapeutic targets for plasma exchange.

    Science.gov (United States)

    Williams, Mark E; Balogun, Rasheed A

    2014-01-01

    Extracorporeal "blood purification," mainly in the form of hemodialysis has been a major portion of the clinical activity of many nephrologists for the past 5 decades. A possibly older procedure, therapeutic plasma exchange, separates and then removes plasma as a method of removing pathogenic material from the patient. In contrast to hemodialysis, therapeutic plasma exchange preferentially removes biologic substances of high molecular weight such as autoantibodies or alloantibodies, antigen-antibody complexes, and Ig paraproteins. These molecular targets may be cleared through two alternative procedures: centrifugal separation and membrane separation. This review presents operational features of each procedure, with relevance to the nephrologist. Kinetics of removal of these plasma constituents are based on the principles of separation by the apheresis technique and by features specific to each molecular target, including their production and compartmentalization in the body. Molecular targets for common renal conditions requiring therapeutic plasma exchange are also discussed in detail.

  12. Plasma exchange for renal vasculitis and idiopathic rapidly progressive glomerulonephritis: a meta-analysis

    DEFF Research Database (Denmark)

    Walsh, Michael; Catapano, Fausta; Szpirt, Wladimir;

    2011-01-01

    Plasma exchange may be effective adjunctive treatment for renal vasculitis. We performed a systematic review and meta-analysis of randomized controlled trials of plasma exchange for renal vasculitis.......Plasma exchange may be effective adjunctive treatment for renal vasculitis. We performed a systematic review and meta-analysis of randomized controlled trials of plasma exchange for renal vasculitis....

  13. Plasma Exchange in the Management of Catastrophic Antiphospholipid Syndrome

    Directory of Open Access Journals (Sweden)

    Dimitri Titeca-Beauport

    2016-01-01

    Full Text Available Objective. Report of a case of catastrophic antiphospholipid syndrome (CAPS with multiple organ involvement leading to a life-threatening condition despite early combination corticosteroid and heparin therapy. Initiation of plasma exchange led to rapid improvement of the patient’s general condition. Design. Case report. Setting. University teaching hospital medical intensive care unit. Patient. Single case: 52-year-old man hospitalized for catastrophic antiphospholipid syndrome (CAPS with cardiac, renal, and cutaneous involvement. Despite early methylprednisolone and heparin therapy, the patient’s condition progressively deteriorated, resulting in acute renal failure, right adrenal hemorrhage, and pulmonary involvement, leading to acute respiratory distress on day 6, requiring high-flow nasal cannula oxygen therapy with FiO2 of 1.0. Interventions. Plasma exchange was started on day 6. Endpoints and Main Results. A marked improvement of the patient’s general condition was observed after initiation of plasma exchange, with successful weaning of oxygen therapy and normalization of platelet count, troponin, and serum creatinine within four days. Conclusions. This case illustrates the efficacy of plasma exchange in CAPS and the difficulty for physicians to determine the optimal timing of plasma exchange.

  14. Plasma Exchange in the Management of Catastrophic Antiphospholipid Syndrome.

    Science.gov (United States)

    Titeca-Beauport, Dimitri; Salle, Valery; Kontar, Loay; Maizel, Julien; Choukroun, Gabriel

    2016-01-01

    Objective. Report of a case of catastrophic antiphospholipid syndrome (CAPS) with multiple organ involvement leading to a life-threatening condition despite early combination corticosteroid and heparin therapy. Initiation of plasma exchange led to rapid improvement of the patient's general condition. Design. Setting. University teaching hospital medical intensive care unit. Patient. Single case: 52-year-old man hospitalized for catastrophic antiphospholipid syndrome (CAPS) with cardiac, renal, and cutaneous involvement. Despite early methylprednisolone and heparin therapy, the patient's condition progressively deteriorated, resulting in acute renal failure, right adrenal hemorrhage, and pulmonary involvement, leading to acute respiratory distress on day 6, requiring high-flow nasal cannula oxygen therapy with FiO2 of 1.0. Interventions. Plasma exchange was started on day 6. Endpoints and Main Results. A marked improvement of the patient's general condition was observed after initiation of plasma exchange, with successful weaning of oxygen therapy and normalization of platelet count, troponin, and serum creatinine within four days. Conclusions. This case illustrates the efficacy of plasma exchange in CAPS and the difficulty for physicians to determine the optimal timing of plasma exchange.

  15. Plasma Exchange in the Management of Catastrophic Antiphospholipid Syndrome

    Science.gov (United States)

    Salle, Valery; Kontar, Loay; Maizel, Julien

    2016-01-01

    Objective. Report of a case of catastrophic antiphospholipid syndrome (CAPS) with multiple organ involvement leading to a life-threatening condition despite early combination corticosteroid and heparin therapy. Initiation of plasma exchange led to rapid improvement of the patient's general condition. Design. Case report. Setting. University teaching hospital medical intensive care unit. Patient. Single case: 52-year-old man hospitalized for catastrophic antiphospholipid syndrome (CAPS) with cardiac, renal, and cutaneous involvement. Despite early methylprednisolone and heparin therapy, the patient's condition progressively deteriorated, resulting in acute renal failure, right adrenal hemorrhage, and pulmonary involvement, leading to acute respiratory distress on day 6, requiring high-flow nasal cannula oxygen therapy with FiO2 of 1.0. Interventions. Plasma exchange was started on day 6. Endpoints and Main Results. A marked improvement of the patient's general condition was observed after initiation of plasma exchange, with successful weaning of oxygen therapy and normalization of platelet count, troponin, and serum creatinine within four days. Conclusions. This case illustrates the efficacy of plasma exchange in CAPS and the difficulty for physicians to determine the optimal timing of plasma exchange. PMID:27833765

  16. Ferrokinetics: a biologic model for plasma iron exchange in man.

    Science.gov (United States)

    Cook, J D; Marsaglia, G; Eschbach, J W; Funk, D D; Finch, C A

    1970-02-01

    A method is presented for calculating internal iron kinetics. An early reflux associated with extravascular exchange and a late reflux associated with erythropoiesis are described. A biologic model of iron exchange is proposed in which erythron iron turnover is divided into an effective portion (iron fixed in circulating red cells) and wastage iron of erythropoiesis (late reflux). Nonerythroid iron exchange also has a fixed portion (parenchymal uptake) and an early reflux (lymphatic circuit), both of which correlate in amount with the amount of plasma iron. Ferrokinetic measurements in normal subjects and in various pathologic states are presented to validate the model.

  17. SNS potential with exchange field in quantum dusty plasmas

    Science.gov (United States)

    Zeba, I.; Batool, Maryam; Khan, Arroj A.; Jamil, M.; Rozina, Ch

    2017-02-01

    The shielding potential of a static test charge is studied in quantum dusty plasmas. The plasma system consisting upon electrons, ions and negatively static charged dust species, is embedded in an ambient magnetic field. The modified equation of dispersion is derived using quantum hydrodynamic model (QHD) for magnetized plasmas. The quantum effects are inculcated through Fermi degenerate pressure, tunneling effect and exchange-correlation effects. The study of shielding is important to know the existence of the silence zones in space and astrophysical objects as well as crystal formation. The graphical description of the normalized potential depict the significance of the exchange and correlation effects arising through spin and other variables on the shielding potential.

  18. Exchange corrections in a low-temperature plasma.

    Science.gov (United States)

    Ekman, Robin; Zamanian, Jens; Brodin, Gert

    2015-07-01

    We have studied the exchange corrections to linear electrostatic wave propagation in a plasma using a quantum kinetic formalism. Specifically, we have considered the zero-temperature limit. In order to simplify the calculations we have focused on the long-wavelength limit, i.e., wavelengths much longer than the de Broglie wavelength. For the case of ion-acoustic waves we have calculated the exchange correction both to the damping rate and the real part of the frequency. For Langmuir waves the frequency shift due to exchange effects is found. Our results are compared with the frequency shifts deduced from commonly used exchange potentials which are computed from density-functional theory.

  19. [Therapeutic plasma exchange: a review of the literature].

    Science.gov (United States)

    Andrulli, Simeone; Bigi, Maria Carla; Granata, Antonio; Cossu, Maria; Logias, Francesco

    2012-01-01

    Therapeutic plasma exchange is an extracorporeal plasmapheresis method for removing high-molecular-weight pathogens and toxins from the circulation. It can be indicated in many clinical conditions, both kidney-related and non-kidney-related. This review focuses on clinical trials related to Goodpasture syndrome, thrombotic thrombocytopenic purpura, and acute renal insufficiency due to multiple myeloma. It also discusses the difficulties and opportunities associated with the development of a randomized controlled multicenter study and of a web-based database. Finally, we report a summary of the risks and complications of therapeutic plasma exchange and how we can update the information on their frequency and seriousness by means of a longitudinal prospective multicenter study open to all centers performing the procedure.

  20. Controlled trial of plasma exchange in treatment of Raynaud's syndrome.

    Science.gov (United States)

    O'Reilly, M J; Talpos, G; Roberts, V C; White, J M; Cotton, L T

    1979-01-01

    Twenty-seven patients with Raynaud's syndrome had their digital vessel patency assessed by Doppler ultrasound after different thermal stresses. Digital vessel patency rates differed significantly after stresses at 15 degrees C and 45 degrees C. In a randomised controlled trial placebo and heparin had no effect either on patients' symptoms or on the patency of their digital vessels. Plasma exchange improved both symptoms and vessel patency rates at 15 degrees C and 21 degrees C. Improvement in seven out of eight of these patients has been maintained for six months. Assessing digital vessel patency by Doppler techniques allow continuous, atraumatic, and safe evaluation of the effects of different methods of treatment on the patency of the digital vessels and has helped to indicate that plasma exchange is a useful adjunct in the management of patients with severe Raynaud's syndrome. PMID:376042

  1. Charge-exchange source terms in magnetohydrodynamic plasmas

    Science.gov (United States)

    DeStefano, Anthony M.; Heerikhuisen, Jacob

    2017-05-01

    In the modeling of space plasma environments, source terms are often used to couple separate species of particles and/or fluids. There have been many techniques developed over the years to make such coupling more tractable while maintaining maximum physical fidelity. In our current application we use the formalism of the Boltzmann collision integral to compute source terms due to charge-exchange events in the heliosphere. The charge-exchange cross sections often encountered in heliospheric interactions can be fit to laboratory data, but in most cases cannot be directly integrated over analytically. Therefore, researchers often employ various levels of approximation, either semi-analytic or numerical. We explore several assumptions to the charge-exchange source term integrals, namely using Maxwellian velocity spaces for like-mass species and either hard-sphere, power-law, or exact forms of the cross section.

  2. Plasma Adiponectin Levels in Acute Liver Failure Patients Treated with Plasma Filtration with Dialysis and Plasma Exchange.

    Science.gov (United States)

    Yamamoto, Hiroshi; Nakae, Hajime; Uji, Yoshitaka; Maeda, Kazuhisa; Tani, Tohru; Eguchi, Yutaka

    2015-08-01

    Plasma filtration with dialysis (PDF) is a blood purification therapy in which simple plasma exchange (PE) is performed using a selective membrane plasma separator while the dialysate flows outside of the hollow fibers. Improvement of hypoadiponectinemia is considered to be a useful therapeutic approach for ameliorating fatal conditions including cardio-metabolic and infectious disease. We investigated the effects of PDF in comparison to PE in terms of plasma adiponectin (APN) changes in patients with acute liver failure. Seventeen patients with liver failure were studied; PDF was performed 55 times and PE 14 times. Plasma APN levels increased significantly after PDF, while decreasing significantly after PE. PDF appears to be among the most useful blood purification therapies in acute liver failure cases in terms of increasing APN levels.

  3. Numerical calculation of charge exchange cross sections for plasma diagnostics

    Science.gov (United States)

    Mendez, Luis

    2016-09-01

    The diagnostics of impurity density and temperature in the plasma core in tokamak plasmas is carried out by applying the charge exchange recombination spectroscopy (CXRS) technique, where a fast beam of H atoms collides with the plasma particles leading to electron capture reactions with the impurity ions. The diagnostics is based on the emission of the excited ions formed in the electron capture. The application of the CXRS requires the knowledge of accurate state-selective cross sections, which in general are not accessible experimentally, and the calculation of cross sections for the high n capture levels, required for the diagnostics in the intermediate energy domain of the probe beam, is particularly difficult. In this work, we present a lattice numerical method to solve the time dependent Schrödinger equation. The method is based on the GridTDSE package, it is applicable in the wide energy range 1 - 500 keV/u and can be used to assess the accuracy of previous calculations. The application of the method will be illustrated with calculations for collisions of multiply charged ions with H. Work partially supported by project ENE2014-52432-R (Secretaria de Estado de I+D+i, Spain).

  4. Charge exchange in fluid description of partially ionized plasmas

    CERN Document Server

    Vranjes, J; Luna, M

    2015-01-01

    The effects of charge exchange on waves propagating in weakly ionized plasmas are discussed. It is shown that for low-frequency processes, ions and neutrals should be treated as a single fluid with some effective charge on all of them. We have derived a new momentum equation which should be used in such an environment. As a result, the low-frequency magnetic waves can propagate even if particles are not magnetized, which is entirely due to the charge exchange and the fact that it is not possible to separate particles into two different populations as charged and neutral species. So there can be no friction force between ions and neutrals in the usual sense. The mean force per particle is proportional to the ionization ratio $n_i/(n_i+ n_n)$. Regarding the application of the theory to the Alfven wave propagation in the lower solar atmosphere, the results predict that the plane of displacement of the fluid must change by 90 degrees when an Alfven wave propagates from the area where particles are un-magnetized (...

  5. [Efficacy of plasma exchange combined with fetal hepacyties on viral hepatitis gravis].

    Science.gov (United States)

    Zheng, X H; Tang, X P; Chen, J

    2001-10-28

    To evaluate the efficacy of mid-artificial liver support system (ALSS) on viral hepatitis gravis. One hundred and thirty eight patients with hepatitis gravis were treated with plasma exchange combined with fetal hepacyties, fifty six patients were treated with plasma exchange and other forty eight patients were treated with fetal hepacyties respectively. The liver function was examined in all patients before ALSS. The liver function, amino acid spectrum and cardiac muscle enzyme were examined before and after ALSS in patients treated with plasma exchange and fetal hepacyties. It showed that the survival rate of the patients treated with plasma exchange combined with fetal hepacyties was higher than that of the patients only treated with plasma exchange or fetal hepacyties (P viral hepatits gravis.

  6. Cascade filtration for TTP: an effective alternative to plasma exchange with cryodepleted plasma.

    Science.gov (United States)

    Bruni, R; Giannini, G; Lercari, G; Bo, A; Florio, G; De Luigi, M C; Marmont, A; Gobbi, A; Damasio, E; Valbonesi, M

    1999-12-01

    TTP remains enigmatic both in terms of etiology and management. The most recent approach is aggressive plasma exchange (PE) employing cryopoor plasma for replacement, based on the pathogenetic relevance given to exceedingly large Von Willebrand (VWF) multimers in the determination of the syndrome with normalization during remission. PE with fresh frozen plasma (FFP) is better than FFP infusion as shown by a recent Canadian study, supporting the theory that to treat TTP an offending circulating agent needs to be removed from the patient's plasma in contrast to the hypothesis that a missing factor is to be given along with FFP. A more recent hypothesis is supported by the results of studies published by the end of 1998 [Moake J, Chintagumpala M, Turner N et al. Blood 1994;84:490-97; Moake J, McPherson PD. Am J Med 1989;87: 3-9N] which would show that TTP is mediated by auto-antibodies to VWF-cleaving protease, or is the result of deficiency of the protease ascribed to abnormalities in its production, function or survival. Plasmapheresis without plasma infusion is relatively ineffective perhaps because it does not increase the protease activity. Cascade filtration (CF) is the autologous counterpart of plasmapheresis. It has been used by our group since 1980 to remove from patients plasma macromolecules such as VWF, fibrinogen, LDL and circulatory immune complexes (CIC). After secondary filtration, the autologous plasma has a composition which is very similar to that of allogeneic plasma after cryoprecipitation, a product which used in the management of TTP. Based on this knowledge, in 1994 we began to use CF in the treatment of TTP patients. In the beginning (7 patients) CF was combined with a decreasing number of conventional PEs using allogeneic plasma for substitution. Lately only CF with some plasma supplementation has been used in the last 9 cases. From a clinical point of view our 16 patients achieved remission after a number of treatments (11 +/- 7) that

  7. Plasma Exchange in Severe Attacks of Neuromyelitis Optica

    Directory of Open Access Journals (Sweden)

    Mickael Bonnan

    2012-01-01

    Full Text Available Background. Neuromyelitis optica (NMO attacks are poorly controlled by steroids and evolve in stepwise neurological impairments. Assuming the strong humoral response underlying NMO attacks, plasma exchange (PLEX is an appropriate technique in severe NMO attacks. Objective. Presenting an up-to-date review of the literature of PLEX in NMO. Methods. We summarize the rationale of PLEX in relation with the physiology of NMO, the main technical aspects, and the available studies. Results. PLEX in severe attacks from myelitis or optic neuritis are associated with a better outcome, depending on PLEX delay (“time is cord and eyes”. NMO-IgG status has no influence. Finally, we build up an original concept linking the inner dynamic of the lesion, the timing of PLEX onset and the expected clinical results. Conclusion. PLEX is a safe and efficient add-on therapy in NMO, in synergy with steroids. Large therapeutic trials are required to definitely assess the procedure and define the time opportunity window.

  8. Current indication of plasma exchanges in nephrology: A systematic review

    Directory of Open Access Journals (Sweden)

    Sidy M Seck

    2011-01-01

    Full Text Available Therapeutic plasma exchange (TPE has been firstly performed with centrifugation devices used in blood banking procedures. Nowadays, TPE is increasingly performed in intensive care units using hemodiafiltration generators that ensure better efficiency and simplicity. However, prescription for the different medical pathologies depends on weak evidence-based recommen-dations, and is often guided by the clinician′s own experience. In this review, we briefly recall the rationale of TPE prescription before discussing the evidence level of common indications of TPE in nephrology. Currently, strong evidence-based data for the benefit of TPE is clearly demonstrated in renal diseases such as hemolytic uremic syndrome, anti-glomerular basement membrane vasculitis, and recurrent glomerulonephritis after kidney transplantation and management of humoral renal allograft rejection in high-risk recipients. However, the other indications of TPE, such as renal vasculitis associated with anti-neutrophil cytoplasmic antibodies, mixed cryoglobulinemia, periarte-ritis nodosa, and acute renal failure in myeloma are still controversial. Finally, TPE have been found to be clearly inefficient in lupus nephritis, except for patients with associated thrombotic mic-roangiopathy or catastrophic antiphospholipid antibodies syndrome. More randomized clinical trials are required to precisely place TPE in the management of renal diseases. Meanwhile, the decision to use this burdensome and costly therapy should be individualized according to its proven benefits and potential complications.

  9. Exchange effects in Coulomb quantum plasmas: Dispersion of waves in 2D and 3D mediums

    CERN Document Server

    Andreev, Pavel A

    2014-01-01

    We describe quantum hydrodynamic equations with the Coulomb exchange interaction for three and two dimensional plasmas. Explicit form of the force densities are derived. We present non-linear Schrodinger equations (NLSEs) for the Coulomb quantum plasmas with the exchange interaction. We show contribution of the exchange interaction in the dispersion of the Langmuir, and ion-acoustic waves. We consider influence of the spin polarization ratio on strength of the Coulomb exchange interaction. This is important since exchange interaction between particles with same spin direction and particles with opposite spin directions are different. At small particle concentrations $n_{0}>10^{25}cm^{-3}$ the Fermi pressure prevails over the exchange interaction for all polarizations. Similar picture we obtain for two dimensional quantum plasmas.

  10. Give or take? Intravenous immunoglobulin or plasma exchange for Guillain-Barré syndrome.

    Science.gov (United States)

    Hughes, Richard A C

    2011-07-28

    A new randomised controlled trial suggested that plasma exchange hastened removal from the ventilator in mechanically ventilated children with Guillain-Barré syndrome compared with intravenous immunoglobulin. Two larger trials in adults showed the opposite result.

  11. Plasma Exchange for Renal Vasculitis and Idiopathic Rapidly Progressive Glomerulonephritis: A Meta-analysis

    DEFF Research Database (Denmark)

    Walsh, Michael; Catapano, Fausta; Szpirt, Wladimir;

    2010-01-01

    BACKGROUND:: Plasma exchange may be effective adjunctive treatment for renal vasculitis. We performed a systematic review and meta-analysis of randomized controlled trials of plasma exchange for renal vasculitis. STUDY DESIGN:: Systematic review and meta-analysis of articles identified from...... electronic databases, bibliographies, and studies identified by experts. Data were abstracted in parallel by 2 reviewers. SETTING & POPULATION:: Adults with idiopathic renal vasculitis or rapidly progressive glomerulonephritis. SELECTION CRITERIA FOR STUDIES:: Randomized controlled trials that compared...... standard care with standard care plus adjuvant plasma exchange in adult patients with either renal vasculitis or idiopathic rapidly progressive glomerulonephritis. INTERVENTION:: Adjuvant plasma exchange. OUTCOME:: Composite of end-stage renal disease or death. RESULTS:: We identified 9 trials including...

  12. Plasma extraction rate and collection efficiency during therapeutic plasma exchange with Spectra Optia in comparison with Haemonetics MCS+.

    Science.gov (United States)

    Lambert, Catherine; Gericke, Marion; Smith, Richard; Hermans, Cedric

    2011-01-01

    For therapeutic plasma exchange (TPE), continuous and intermittent flow separators are known to be efficient. This study was undertaken to compare the performances of the Spectra Optia, a continuous flow centrifugal apheresis system recently developed by CaridianBCT, with the Haemonetics Multicomponents System (MCS)+ apheresis system based on intermittent flow centrifugation. The primary objective of the study was to compare the time required to exchange one total plasma volume with both separators. The secondary objectives were to determine the plasma exchange efficiency, the plasma extraction rate, the percentage of target exchange volume achieved, and the loss of cellular components. The study involved prospectively paired comparison of 16 TPE on each device performed in patients with chronic diseases treated with TPE. The time required to exchange 1 total plasma volume was 182 ± 36 minutes for MCS+ procedures and 100 ± 20 minutes for the Spectra Optia procedures (P rate was achieved (30.2 ± 4.3 vs 16.8 ± 3.4 mL/min, respectively, P exchange efficiency was slightly better with the Spectra Optia compared with the MCS+ procedures (83.4 ± 7.0 vs 80.0 ± 8.5%, P compared with the MCS+ procedures (1.6 ± 2.3 vs 7.5 ± 4.2%, respectively, P comparable. In conclusion, the Spectra Optia has significantly higher extraction rate and exchange efficiency than the MCS+ allowing to remove the same amount of plasma in less time, by processing less blood. It also removes significantly less platelets than the MCS+ separator.

  13. Efficacy of plasma exchange and immunoadsorption in systemic lupus erythematosus and antiphospholipid syndrome: A systematic review.

    Science.gov (United States)

    Kronbichler, Andreas; Brezina, Biljana; Quintana, Luis F; Jayne, David R W

    2016-01-01

    Extracorporeal treatments have been used since the 1970s in the management of systemic lupus erythematosus (SLE). A randomised controlled trial comparing the efficacy of standard of care (SOC) combined with plasma exchange against SOC alone in patients with lupus nephritis revealed no difference in terms of renal outcome. Subsequently, initial expectations have been dampened and further experience with plasma exchange is mainly limited to observational studies and single case reports. Beneficial effects have been reported in patients with refractory disease course or in pregnancy with prior complications due to SLE and antiphospholipid syndrome. A more specific form of extracorporeal treatment, immunoadsorption (IAS), has emerged as a valuable option in the treatment of SLE. In line with the plasma exchange experience, IAS seems to have beneficial effects in patients with refractory disease, contraindications to standard immunosuppression or during pregnancy. The mechanism IAS relates to autoantibody removal but for plasma exchange removal of activated complement components, coagulation factors, cytokines and microparticles may also be relevant. Both treatment forms have good safety profiles although reactions to blood product replacement in plasma exchange and procedure related complications such as bleeding or catheter-related infections have occurred. There is a need to more clearly define the clinical utility of plasma exchange and IAS in refractory lupus and APS subgroups.

  14. High-volume plasma exchange in patients with acute liver failure

    DEFF Research Database (Denmark)

    Larsen, Fin Stolze; Schmidt, Lars Ebbe; Bernsmeier, Christine

    2016-01-01

    BACKGROUND & AIMS: Acute liver failure (ALF) often results in cardiovascular instability, renal failure, brain oedema and death either due to irreversible shock, cerebral herniation or development of multiple organ failure. High-volume plasma exchange (HVP), defined as exchange of 8-12 or 15...

  15. Preparation of ion-exchange thin film using plasma processes. Plasma process wo mochiita ion kokansei usumaku no sakusei

    Energy Technology Data Exchange (ETDEWEB)

    Ogumi, Z.; Uchimoto, Y. (Kyoto University, Kyoto (Japan). Faculty of Engineering)

    1992-10-31

    The present report describes a study which aims at preparation of a new functional film by plasma polymerization. For this purpose, 4-vinylpyridine monomer is plasma-polymerized to obtain a thin film, which is quaternarized with 1-bromopropane to produce an anion exchange thin film, which is laminated on the surface of a cation-exchange film to make a mono-valent cation perm-selective film. In plasma-polymerization, the relations of polymerizing pressure, as parameter, to the deposition rate of the polymerizerd film and the characteristics of compound were clarified. In preparing the anion-exchange thin film, the preparation of uniform ultrathin films with no pinhole was attempted. For this purpose, the transference number of Cl[sup -] was measured so as to confirm that Cl[sup -] is uniformly distributed and fixed cation groups are distributed uniformly in the film. The perm-selective film exhibited a high mono-valent cation perm-selectivity while its film resistance was increased. This increase is found to be broken down to the resistance of the plasma-polymerization film layer and the resistance of the film interface. The latter arises from the implantation of nitrogen-cointaining species in the plasma onto the surface of the cation exchange film. 26 refs., 10 figs., 2 tabs.

  16. Guillain-Barre syndrome in a 7-month-old boy successfully applied plasma exchange.

    Science.gov (United States)

    Akarcan, Sanem Eren; İşgüder, Rana; Yılmaz, Ünsal; Ayhan, Yüce; Ceylan, Gökhan; Ağın, Hasan

    2016-02-01

    Despite being the most common cause of acute flaccid paralysis in children Guillain-Barré syndrome has a low incidence under 18 years old, and is even rarer under the age of 2. Established treatment regimens include intravenous immunoglobulin and plasma exchange in older children and adults. However very limited data are available for the efficacy and safety of plasma exchange in infants younger than 12 month-old. This article presents the experience of plasma exchange in the case of 7-month-old boy diagnosed with Guillain-Barré syndrome. A 7-month-old boy was referred to the pediatric intensive care unit with a 10-day history of progressive weakness, feeding difficulty and constipation. He was diagnosed with axonal Guillain-Barré syndrome on the basis of clinical and electromyographical findings. The patient recovered fully with intravenous immunoglobulin and plasma exchange. Plasma exchange may be a safe option in the treatment in infants with Guillain-Barré syndrome as young as 7-month-age. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Successful Use of Plasma Exchange in the Treatment of Corticosteroid-Refractory Eosinophilic Granulomatosis with Polyangiitis Associated with Gastrointestinal Manifestations

    Directory of Open Access Journals (Sweden)

    Kohei Tsujimoto

    2016-01-01

    Full Text Available We describe the case of a 33-year-old woman having corticosteroid-refractory eosinophilic granulomatosis with polyangiitis (EGPA who presented with abdominal pain and responded dramatically to plasma exchange. Eosinophilia, asthma history, neuropathy, pulmonary infiltrates, and paranasal sinus abnormalities confirmed the diagnosis of EGPA. Treatment was initiated with 1 g/day of methylprednisolone pulse therapy for 3 days followed by 60 mg/day of intravenous prednisolone without relieving abdominal pain. Then, plasma exchange was performed thrice. Abdominal pain disappeared after the first plasma exchange. Indication of plasma exchange for EGPA remains controversial; however, it may represent a valid option in cases with gastrointestinal involvement.

  18. Evaluation of a new microporous filtration membrane system for therapeutic plasma exchange.

    Science.gov (United States)

    Kurtz, S R; Carey, P M; McGill, M; Pineda, A A; Zaroulis, C G; Case, M T

    1987-01-01

    A new therapeutic plasma exchange device developed by Sarns Inc./3M was evaluated in plasmapheresis of 20 healthy volunteers and in a multicenter clinical study of therapeutic plasma exchange that included 49 patients. Safety and efficacy of plasma separation from whole blood were assessed for a module that contains Durapore microporous surfactant-free polyvinylidene fluoride membrane (Millipore Corp., Bedford, Mass., USA). The extra-corporeal volume was 80 ml. Citrate and heparin anticoagulants were utilized. Mean plasma separation efficiency was 62% with unhindered passage of plasma proteins through the membrane pores and no hemolysis or activation of complement as measured by total hemolytic complement (CH50) and C3 conversion. Mean decrease in platelet count after procedures was 10%. No severe reactions occurred, and citrate effects (13%) were comparable to values reported with centrifugal instruments. The Sarns Inc./3M Therapore device is a rapid, safe and efficient system for plasma exchange and potentially for source plasma collection. The principal benefits are small extracorporeal volume and cell-free filtrate.

  19. Rituximab in a child with autoimmune thrombotic thrombocytopenic purpura refractory to plasma exchange.

    Science.gov (United States)

    Narayanan, Parameswaran; Jayaraman, Aparna; Rustagi, Rashi S; Mahadevan, S; Parameswaran, Sreejith

    2012-07-01

    A nine-year-old girl presented with headache, purpura and mild left hemiparesis. Laboratory evaluation revealed thrombotic microangiopathy with ADAMTS13 deficiency, with auto-antibodies to ADAMTS13. She was treated with plasma exchange and steroids, following which she improved transiently, relapsing within 2 months. The relapse was refractory to conventional therapy and rituximab was tried. She had good response to rituximab and has been in remission for the past 12 months. Rituximab may be a promising option for children with acquired TTP refractory to plasma exchange and steroids.

  20. The use of plasma exchange in Hashimoto's encephalopathy: A case report and review of the literature.

    Science.gov (United States)

    Cook, Melissa K; Malkin, Mark; Karafin, Matthew S

    2015-06-01

    Hashimoto's Encephalopathy (HE) is a very rare condition characterized by psychosis, seizures, cognitive fluctuations, and myoclonus. In a few published cases, plasma exchange has been used due to the theoretical removal of antithyroid peroxidase antibodies (anti-TPO), one of the postulated causes of the condition. We report a case of HE treated by plasma exchange where no clinical or neurophysiologic improvement was observed despite documented reduction of the anti-TPO antibody to levels below the limits of laboratory detection. We discuss these findings in the context of the known literature for this disease process.

  1. Severe Leptospirosis with Multiple Organ Failure Successfully Treated by Plasma Exchange and High-Volume Hemofiltration

    Directory of Open Access Journals (Sweden)

    Vincent Bourquin

    2011-01-01

    Full Text Available Background. Leptospirosis is a spirochetal zoonosis with complex clinical features including renal and liver failure. Case report. We report the case of a Swiss fisherman presenting with leptospirosis. After initial improvement, refractory septic shock and severe liver and kidney failure developed. The expected mortality was estimated at 90% with clinical scores. The patient underwent plasma exchanges and high-volume hemofiltration (HVHF with complete recovery of hepatic and kidney functions. Discussion. Plasma exchanges and HVHF may confer survival benefit on patients with severe leptospirosis, refractory septic shock, and multiple-organ failure.

  2. Plasma code for astrophysical charge exchange emission at X-ray wavelengths

    CERN Document Server

    Gu, Liyi; Raassen, A J J

    2016-01-01

    Charge exchange X-ray emission provides unique insights into the interactions between cold and hot astrophysical plasmas. Besides its own profound science, this emission is also technically crucial to all observations in the X-ray band, since charge exchange with the solar wind often contributes a significant foreground component that contaminates the signal of interest. By approximating the cross sections resolved to $n$ and $l$ atomic subshells, and carrying out complete radiative cascade calculation, we create a new spectral code to evaluate the charge exchange emission in the X-ray band. Comparing to collisional thermal emission, charge exchange radiation exhibits enhanced lines from large-$n$ shells to the ground, as well as large forbidden-to-resonance ratios of triplet transitions. Our new model successfully reproduces an observed high-quality spectrum of comet C/2000 WM1 (LINEAR), which emits purely by charge exchange between solar wind ions and cometary neutrals. It demonstrates that a proper charge ...

  3. Plasma exchange in antineutrophil cytoplasmic antibody-associated vasculitis--a 25-year perspective

    DEFF Research Database (Denmark)

    Szpirt, Wladimir M

    2015-01-01

    Demonstration of a pathogenic role for antineutrophil cytoplasmic antibodies (ANCA) underlies the scientific rationale for plasma exchange (PLEX) in the treatment of ANCA-associated vasculitis (AAV). Most clinical evidence of efficacy concerns the use of PLEX for the recovery of renal function...

  4. Plasma-exchange in the treatment of severe thyrotoxicosis in pregnancy

    NARCIS (Netherlands)

    Derksen, R.H.W.M.; Poortman, J.; Wiel, A. van de; Kinderen, P.J. der; Kater, L.

    1984-01-01

    Three female patients with severe thyrotoxicosis, two of them pregnant 22 and 16 wk, respectively, were treated with plasma-exchange (PE) combined with anti-thyroid drugs. In both pregnant patients PE was an effective adjunct to therapy with low-dose carbimazol. They were both delivered of normal ba

  5. A prospective study of plasma exchange in the treatment of diffuse scleroderma.

    Institute of Scientific and Technical Information of China (English)

    1995-01-01

    A prospective randomized study to compare the efficacy between plasma exchange (PE) plus Dpenicillamine (13 cases) (group Ⅰ)and D-penicillamine alone (16 cases) (group Ⅱ) in the treatment of diffuse scleroderma was carried out. Total skin score, the distance between finger and palm the distance between

  6. Post-transfusion purpura treated with plasma exchange by haemonetics cell separator. A case report

    DEFF Research Database (Denmark)

    Laursen, B; Morling, N; Rosenkvist, J;

    1978-01-01

    A case of post-transfusion purpura in a 61-year-old, multiparous female with a platelet alloantibody (anti-Zwa) in her serum is reported. The patient was successfully treated with plasma exchange by means of a Haemonetics 30 cell separator and corticosteroids. Compared with other therapeutic meas...

  7. Effects of hemoperfusion adsorption and/or plasma exchange in treatment of severe viral hepatitis:A comparative study

    Institute of Scientific and Technical Information of China (English)

    Nian-Hai He; Ying-Jie Wang; Ze-Wen Wang; Jun Liu; Jia-Jia Li; Guo-Dong Liu; Yu-Ming Wang

    2004-01-01

    AIM: Non-bioartificial liver has been applied to clinic for quite a long time, but the reported efficacy has been very different. The aim of this study was to compare the efficacy and safety of hemoperfusion adsorption, plasma exchange and plasma exchange plus hemoperfusion adsorption in treatment of severe viral hepatitis.METHODS: Seventy-five patients with severe viral hepatitis were treated with hemoperfusion adsorption therapy (24cases), plasma exchange therapy (17 cases) and plasma exchange plus hemoperfusion adsorption therapy (34 cases).The data of liver function, renal function, blood routine test,prothrombin time (PT) and prothrombin activity (PTa) preand post-therapy were analyzed.RESULTS: Clinical symptoms of patients improved after treatment. The levels of aminotransferase, total bilirubin,direct bilirubin decreased significantly after 3 therapies (P<0.05 or P<0.01). PT, the level of total serum protein decreased significantly and PTa increased significantly after plasma exchange therapy and plasma exchange plus hemoperfusion adsorption therapy (P<0.05 or P<0.01). The side effects were few and mild in all patients.CONCLUSION: Three therapies were effective in the treatment of severe viral hepatitis. Plasma exchange therapy and plasma exchange plus hemoperfusion adsorption therapy are better than hemoperfusion adsorption therapy.

  8. Effects of hemoperfusion adsorption and/or plasma exchange in treatment of severe viral hepatitis: A comparative study

    Science.gov (United States)

    He, Nian-Hai; Wang, Ying-Jie; Wang, Ze-Wen; Liu, Jun; Li, Jia-Jia; Liu, Guo-Dong; Wang, Yu-Ming

    2004-01-01

    AIM: Non-bioartificial liver has been applied to clinic for quite a long time, but the reported efficacy has been very different. The aim of this study was to compare the efficacy and safety of hemoperfusion adsorption, plasma exchange and plasma exchange plus hemoperfusion adsorption in treatment of severe viral hepatitis. METHODS: Seventy-five patients with severe viral hepatitis were treated with hemoperfusion adsorption therapy (24 cases), plasma exchange therapy (17 cases) and plasma exchange plus hemoperfusion adsorption therapy (34 cases). The data of liver function, renal function, blood routine test, prothrombin time (PT) and prothrombin activity (PTa) pre-and post-therapy were analyzed. RESULTS: Clinical symptoms of patients improved after treatment. The levels of aminotransferase, total bilirubin, direct bilirubin decreased significantly after 3 therapies (P < 0.05 or P < 0.01). PT, the level of total serum protein decreased significantly and PTa increased significantly after plasma exchange therapy and plasma exchange plus hemoperfusion adsorption therapy (P < 0.05 or P < 0.01). The side effects were few and mild in all patients. CONCLUSION: Three therapies were effective in the treatment of severe viral hepatitis. Plasma exchange therapy and plasma exchange plus hemoperfusion adsorption therapy are better than hemoperfusion adsorption therapy. PMID:15069730

  9. Plasma code for astrophysical charge exchange emission at X-ray wavelengths

    Science.gov (United States)

    Gu, Liyi; Kaastra, Jelle; Raassen, A. J. J.

    2016-04-01

    Charge exchange X-ray emission provides unique insight into the interactions between cold and hot astrophysical plasmas. Besides its own profound science, this emission is also technically crucial to all observations in the X-ray band, since charge exchange with the solar wind often contributes a significant foreground component that contaminates the signal of interest. By approximating the cross sections resolved to n and l atomic subshells and carrying out complete radiative cascade calculation, we have created a new spectral code to evaluate the charge exchange emission in the X-ray band. Compared to collisional thermal emission, charge exchange radiation exhibits enhanced lines from large-n shells to the ground, as well as large forbidden-to-resonance ratios of triplet transitions. Our new model successfully reproduces an observed high-quality spectrum of comet C/2000 WM1 (LINEAR), which emits purely by charge exchange between solar wind ions and cometary neutrals. It demonstrates that a proper charge exchange model will allow us to probe the ion properties remotely, including charge state, dynamics, and composition, at the interface between the cold and hot plasmas.

  10. Modulation of waves due to charge-exchange collisions in magnetized partially ionized space plasma

    Energy Technology Data Exchange (ETDEWEB)

    Shaikh, Dastgeer, E-mail: dastgeer.shaikh@uah.ed [Department of Physics and Center for Space Plasma and Aeronomy Research, University of Alabama in Huntsville, Huntsville, AL 35899 (United States); Zank, G.P. [Department of Physics and Center for Space Plasma and Aeronomy Research, University of Alabama in Huntsville, Huntsville, AL 35899 (United States)

    2010-10-04

    A nonlinear time dependent fluid simulation model is developed that describes the evolution of magnetohydrodynamic waves in the presence of collisional and charge exchange interactions of a partially ionized plasma. The partially ionized plasma consists of electrons, ions and a significant number of neutral atoms. In our model, the electrons and ions are described by a single fluid compressible magnetohydrodynamic (MHD) model and are coupled self-consistently to the neutral gas, described by the compressible hydrodynamic equations. Both the plasma and neutral fluids are treated with different energy equations that describe thermal energy exchange processes between them. Based on our self-consistent model, we find that propagating Alfvenic and fast/slow modes grow and damp alternately through a nonlinear modulation process. The modulation appears to be robust and survives strong damping by the neutral component.

  11. Modulation of waves due to charge-exchange collisions in magnetized partially ionized space plasma

    CERN Document Server

    Shaikh, Dastgeer

    2010-01-01

    A nonlinear time dependent fluid simulation model is developed that describes the evolution of magnetohydrodynamic waves in the presence of collisional and charge exchange interactions of a partially ionized plasma. The partially ionized plasma consists of electrons, ions and a significant number of neutral atoms. In our model, the electrons and ions are described by a single fluid compressible magnetohydrodynamic (MHD) model and are coupled self-consistently to the neutral gas, described by the compressible hydrodynamic equations. Both the plasma and neutral fluids are treated with different energy equations that describe thermal energy exchange processes between them. Based on our self-consistent model, we find that propagating Alfv\\'enic and fast/slow modes grow and damp alternately through a nonlinear modulation process. The modulation appears to be robust and survives strong damping by the neutral component.

  12. Charge exchange fast neutral measurement with natural diamond detectors in neon plasma on LHD

    Science.gov (United States)

    Saida, T.; Sasao, M.; Isobe, M.; Krasilnikov, A. V.

    2003-03-01

    Charge exchange (CX) fast neutral spectra produced by ion cyclotron resonance frequency hydrogen minority heating in neon and helium majority plasmas sustained by neutral beam injection were measured with perpendicular Natural Diamond Detectors during the fifth campaign in 2002 on large helical devices (LHDs). It was observed that there were differences between fast neutral spectra shapes in neon plasma and those in helium of the same discharge condition with similar plasma parameters. Dominant CX processes in neon and helium plasmas were studied for ionization components from outside of the last closed flux surface. High-energy proton spectra were obtained by taking account of each charge state distribution and responsible charge exchange cross sections. The high-energy proton tail formations in both plasmas were similar for the same heating regime. The relaxation time tendencies of the effective temperatures of a high-energy proton have also shown no differences, indicating that the acceleration and confinement of energetic ions in LHDs are similar in neon and helium plasmas.

  13. The charge-exchange induced coupling between plasma-gas counterflows in the heliosheath

    Directory of Open Access Journals (Sweden)

    H. J. Fahr

    Full Text Available Many hydrodynamic models have been presented which give similar views of the interaction of the solar wind plasma bubble with the counterstreaming partially ionized interstellar medium. In the more recent of these models it is taken into account that the solar and interstellar hydrodynamic flows of neutral atoms and protons are coupled by mass-, momentum-, and energy-exchange terms due to charge exchange processes. We shall reinvestigate the theoretical basis of this coupling here by use of a simplified description of the heliospheric interface and describe the main physics of the H-atom penetration through the more or less standing well-known plasma wall ahead of the heliopause. Thereby we can show that the type of charge exchange coupling terms used in up-to-now hydrodynamic treatments unavoidably leads to an O-type critical point at the sonic point of the H-atom flow, thus not allowing for a continuation of the integration of the hydrodynamic set of differential equations. The remedy for this problem is given by a more accurate formulation of the momentum exchange term for quasi-and sub-sonic H-atom flows. With a refined momentum exchange term derived from basic kinetic Boltzmann principles, we instead arrive at a characteristic equation with an X-type critical point, allowing for a continuous solution from supersonic to subsonic flow conditions. This necessitates that the often treated problem of the propagation of inter-stellar H-atoms through the heliosheath has to be solved using these newly derived, differently effective plasma – gas friction forces. Substantially different results are to be expected from this context for the filtration efficiency of the heliospheric interface.

    Key words. Interplanetary physics (heliopause and solar wind termination; interstellar gas – Ionosphere (plasma temperature and density

  14. One year's experience using a rotating filter for therapeutic plasma exchange.

    Science.gov (United States)

    Kaplan, A A; Halley, S E; Reardon, J; Sevigny, J

    1989-01-01

    The authors previously demonstrated the feasibility of using a rotating filter system for therapeutic plasma exchange. They now report on the technical details of a 1 year clinical experience. Seventeen patients underwent 188 treatments. Hemoaccess was provided by antecubital veins (147 Rx), femoral catheters (37 Rx), or an a-v fistula (3 Rx). Blood flows ranged from 75 to 100 ml/min. Net plasma removed per treatment was 3,231 +/- 53 ml (mean +/- SE, n = 188). Mean plasma removal rate per treatment was 40.2 +/- 0.6 ml/min; mean treatment time was 83 +/- 2 min. Platelet counts before and after treatment revealed a 15 +/- 4% decline (n = 46 Rx). Despite filtration fractions up to 86% there was no evidence of significant membrane plugging or hemolysis. For semiselective removal of cholesterol, the rotating filter was used in a cascade system with a secondary filter. Eighty percent of processed plasma was returned to the patient, but the treatment time was prolonged by 37% and the total cholesterol removed was 26% less when compared with the single pass system. The authors conclude that an inexpensive rotating filter can provide a highly efficient plasma exchange. The inherent efficiency of this system must be considered when evaluating its use with secondary filtration techniques.

  15. False-positive serology following intravenous immunoglobulin and plasma exchange through transfusion of fresh frozen plasma in a patient with pemphigus vulgaris.

    Science.gov (United States)

    Nomura, Hisashi; Honda, Haruki; Egami, Shohei; Yokoyama, Tomoaki; Fujimoto, Atsushi; Ishikawa, Makiko; Sugiura, Makoto

    2015-04-01

    Intravenous immunoglobulin therapy and plasma exchange through transfusion of fresh frozen plasma are therapeutic options for patients with refractory pemphigus vulgaris. Passive acquisition of various clinically important antibodies through these therapies can occur, leading to false serology and negatively affecting patients' clinical care. It is recommended that dermatologists recognize the possibility of these phenomena and interpret them appropriately. Here, we report false-positive serology following intravenous immunoglobulin therapy and plasma exchange through transfusion of fresh frozen plasma in a patient with refractory pemphigus vulgaris. We also discuss the measure for misinterpretation and unnecessary clinical intervention.

  16. Two unusual cases with Wilson's disease: hepatoma and fulminant hepatitis treated with plasma exchange.

    Science.gov (United States)

    Aydinli, Musa; Harmanci, Ozgur; Ersoy, Osman; Iskit, Arzu T.; Ozcebe, Osman; Abbasoglu, Osman; Bayraktar, Yusuf

    2006-01-01

    We report two atypical cases of Wilson's disease. The first case is a 22-year-old male patient with a history of disease for 15 years and diagnosed as Wilson's disease upon investigations. Alpha-fetoprotein level was found elevated and computed tomography showed a 3.5-cm liver mass. Hepatocellular carcinoma was diagnosed. Radiofrequency ablation and liver transplantation were performed successfully. The second case is a 24-year-old female patient who presented with fulminant hepatitis. Urinary copper excretion and ceruloplasmin levels were suggestive of Wilson's disease. Despite chelation therapy, no improvement was observed. Plasma exchange therapy was performed for seven days. Her clinical status improved, and transplantation was no longer needed. To conclude, although hepatoma is rarely seen in Wilson's disease, patients should be examined regularly to diagnose it in a treatable stage. Removal of copper and toxic metabolites with plasma exchange therapy may be a way of treatment for fulminant hepatitis associated with Wilson's disease. PMID:17225847

  17. A Rare case of Guillain-Barré syndrome in pregnancy treated with plasma exchange

    Directory of Open Access Journals (Sweden)

    Rahul Vasudev

    2014-01-01

    Full Text Available Guillain-Barre syndromé (GBS is an autoimmune disorder. It is rare in pregnancy as there is a decrease in cell-mediated immunity. A case of 28-year-old pregnant woman who presented with acute flaccid quadriplegia suffering from GBS is discussed in this study. She was treated with plasma exchange in her immediate post-partum period. The management of GBS in pregnancy has been discussed.

  18. A Case of Lewis-Sumner Syndrome Showing Dramatic Improvement after Plasma Exchange

    OpenAIRE

    Park, Young-Eun; Yook, Ji-Won; Kim, Dae-Seong

    2010-01-01

    We report a patient with Lewis-Sumner syndrome (LSS) who showed an improvement only with plasma exchange (PE). The patient, 32-yr old man, had progressive multifocal motor-sensory deficits with persistent, multiple conduction blocks and marked slowing of NCVs. Nerve pathology supported a diagnosis of demyelinating neuropathy by revealing marked loss of myelinated fibers with inter- and intrafascicular variation. Although the patient was refractory to treatment with corticosteroid and intraven...

  19. Therapeutic plasma exchange-A new dawn in the treatment of pemphigus vulgaris

    Directory of Open Access Journals (Sweden)

    Rajesh Kumar

    2015-01-01

    Full Text Available Pemphigus vulgaris is an autoimmune disorder that involves intraepithelial blistering and sores of skin and mucous membrane. It generally correlates with the levels of circulating autoantibodies; their removal seems a reasonable therapeutic approach. Therapeutic plasma exchange is hypothesized to remove pathogenic autoantibodies and has been used in refractory or severe cases. It may be considered for rapid control of severe or recalcitrant pemphigus vulgaris and should be combined with use of concomitant immuno-suppressive.

  20. Therapeutic plasma exchange in patients with neurological diseases: multicenter retrospective analysis.

    Science.gov (United States)

    Kaya, Emin; Keklik, Muzaffer; Sencan, Mehmet; Yilmaz, Mehmet; Keskin, Ali; Kiki, Ilhami; Erkurt, Mehmet Ali; Sivgin, Serdar; Korkmaz, Serdal; Okan, Vahap; Doğu, Mehmet Hilmi; Unal, Ali; Cetin, Mustafa; Altuntaş, Fevzi; Ilhan, Osman

    2013-06-01

    Therapeutic plasma exchange (TPE), is a procedure, changing pathologic substances in the plasma of patients with replacement fluid. TPE has an increasing list of indications in recent years such as neurological, connective tissue, hematological, nephrological, endocrinological and metabolic disorders. We report our multicenter data about therapeutic plasma exchange in patients with neurological diseases. Six University Hospitals' aphaeresis units medical records about neurologic diseases were reviewed retrospectively. Hundred and fifteen patients and 771 TPE sessions from six aphaeresis units' were included to this study. Of the 115 patients, 53 (46%) were men and 62 (54%) were women. The median age was 50 (range: 5-85) years. Of these patients 58.3% were Guillain-Barre syndrome (GBS), 17.4% were acute disseminated encephalomyelitis (ADEM), 10.4% were chronic inflammatory demyelinating polyradiculoneuropathy (CIDP), 7% were multiple sclerosis, 6.1% were myasthenia gravis (MG) and 0.9% were Wilson disease (WD). The median number of TPE sessions per patient was 5 (range 1-72). Human albumin was used as a replacement fluid in 66% and fresh frozen plasma was used in 34% of cases. TPE was done through central venous catheters in 66%, and peripheral venous access in 34% of patients. Some complications were seen in patients (18.3%) during TPE sessions. These complications were, complications related to catheter placement procedure (8.7%), hypotension (3.5%), hypocalcaemia (3.5%) and allergic reactions (1.7%). The complication ratios were 2.7% in total 771 TPE procedures. TPE procedure was terminated in 6% of sessions depending on these complications. Overall responses to TPE were noted in 89.5% of patients. In conclusion; Therapeutic plasma exchange is an effective treatment option in several neurologic diseases.

  1. Plasma exchange for induction and cyclosporine A for maintenance of remission in Wegener's granulomatosis--a clinical randomized controlled trial

    DEFF Research Database (Denmark)

    Szpirt, Wladimir M; Heaf, James G; Petersen, Jørgen

    2011-01-01

    The use of plasma exchange (PE) for induction treatment of anti-neutrophil cytoplasm autoantibody (ANCA)-associated vasculitis (AAV), including Wegener's granulomatosis (WG), is still controversial. The use of PE in AAV is not commonly accepted in patients with a plasma creatinine......The use of plasma exchange (PE) for induction treatment of anti-neutrophil cytoplasm autoantibody (ANCA)-associated vasculitis (AAV), including Wegener's granulomatosis (WG), is still controversial. The use of PE in AAV is not commonly accepted in patients with a plasma creatinine...

  2. Low energy plasma treatment of a proton exchange membrane used for low temperature fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Charles, C [Space Plasma, Power, and Propulsion group, Research School of Physical Sciences and Engineering, Australian National University, Canberra, ACT 0200 (Australia); Ramdutt, D [Space Plasma, Power, and Propulsion group, Research School of Physical Sciences and Engineering, Australian National University, Canberra, ACT 0200 (Australia); Brault, P [GREMI-CNRS Laboratory, University of Orleans, BP 6744, F-45067, Orleans (France); Caillard, A [Space Plasma, Power, and Propulsion group, Research School of Physical Sciences and Engineering, Australian National University, Canberra, ACT 0200 (Australia); Bulla, D [Space Plasma, Power, and Propulsion group, Research School of Physical Sciences and Engineering, Australian National University, Canberra, ACT 0200 (Australia); Boswell, R [Space Plasma, Power, and Propulsion group, Research School of Physical Sciences and Engineering, Australian National University, Canberra, ACT 0200 (Australia); Rabat, H [GREMI-CNRS Laboratory, University of Orleans, BP 6744, F-45067, Orleans (France); Dicks, A [School of Engineering, University of Queensland, Brisbane, QLD 4072 (Australia)

    2007-05-15

    A low energy ({approx}30 V) plasma treatment of Nafion, a commercial proton exchange membrane used for low temperature fuel cells, is performed in a helicon radiofrequency (13.56 MHz) plasma system. For argon densities in the 10{sup 9}-10{sup 10} cm{sup -3} range, the water contact angle (hydrophobicity) of the membrane surface linearly decreases with an increase in the plasma energy dose, which is maintained below 5.1 J cm{sup -2}, and which results from the combination of an ion energy dose (up to 3.8 J cm{sup -2}) and a photon (mostly UV) energy dose (up to 1.3 J cm{sup -2}). The decrease in water contact angle is essentially a result of the energy brought to the surface by ion bombardment. The measured effect of the energy brought to the surface by UV light is found to be negligible.

  3. Low energy plasma treatment of a proton exchange membrane used for low temperature fuel cells

    Science.gov (United States)

    Charles, C.; Ramdutt, D.; Brault, P.; Caillard, A.; Bulla, D.; Boswell, R.; Rabat, H.; Dicks, A.

    2007-05-01

    A low energy (~30 V) plasma treatment of Nafion, a commercial proton exchange membrane used for low temperature fuel cells, is performed in a helicon radiofrequency (13.56 MHz) plasma system. For argon densities in the 109-1010 cm-3 range, the water contact angle (hydrophobicity) of the membrane surface linearly decreases with an increase in the plasma energy dose, which is maintained below 5.1 J cm-2, and which results from the combination of an ion energy dose (up to 3.8 J cm-2) and a photon (mostly UV) energy dose (up to 1.3 J cm-2). The decrease in water contact angle is essentially a result of the energy brought to the surface by ion bombardment. The measured effect of the energy brought to the surface by UV light is found to be negligible.

  4. Charge-exchange recombination spectroscopy of the plasma ion temperature at the T-10 tokamak

    Science.gov (United States)

    Krupin, V. A.; Tugarinov, S. N.; Barsukov, A. G.; Dnestrovskij, A. Yu.; Klyuchnikov, L. A.; Korobov, K. V.; Krasnyanskii, S. A.; Naumenko, N. N.; Nemets, A. R.; Sushkov, A. V.; Tilinin, G. N.

    2013-08-01

    Charge-exchange recombination spectroscopy (CXRS) based on a diagnostic neutral beam has been developed at the T-10 tokamak. The diagnostics allows one to measure the ion temperature profile in the cross section of the plasma column. In T-10 experiments, the measurement technique was adjusted and the elements of the CXRS diagnostics for ITER were tested. The used spectroscopic equipment makes it possible to reliably determine the ion temperature from the Doppler broadening of impurity lines (helium, carbon), as well as of the spectral lines of the working gas. The profiles of the plasma ion temperature in deuterium and helium discharges were measured at different plasma currents and densities, including with the use of active Doppler measurements of lines of different elements. The validity and reliability of ion temperature measurements performed by means of the developed CXRS diagnostics are analyzed.

  5. Hydrogen–deuterium exchange on plasma-exposed W and SS surface

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ikuji, E-mail: takagi@nucleng.kyoto-u.ac.jp; Nomura, Shinji; Minamimoto, Toshihiro; Akiyoshi, Masafumi; Kobayashi, Taishi; Sasaki, Takayuki

    2015-08-15

    The desorption cross section for hydrogen isotopes adsorbed on stainless steel (SS) and tungsten (W) has been evaluated experimentally to provide basic information on tritium exchange. One side of a sample sheet was alternately exposed to H and D plasma, and deuterium density on the surface was repeatedly observed using nuclear reaction analysis (NRA) under continuous plasma exposure. From the time dependent change in the deuterium density, the desorption cross sections for SS and W were estimated to be 6.9 ± 2.3 × 10{sup −23} m{sup 2} and 4.6 ± 1.0 × 10{sup −23} m{sup 2}, respectively. No significant differences in the cross section between H and D plasma were observed. Recombinative desorption was found to dominate the desorption process owing to the low incident energy of hydrogen atoms.

  6. Plasma-exchange as a "rescue therapy" for dermato/polymyositis in acute phase. Experience in three young patients.

    Science.gov (United States)

    Cozzi, Franco; Marson, Piero; Pigatto, Erika; Tison, Tiziana; Polito, Pamela; Galozzi, Paola; De Silvestro, Giustina; Punzi, Leonardo

    2015-12-01

    There are few data in the literature supporting the efficacy of plasma-exchange in dermato/polymyositis. The authors report three cases of patients with acute disease phase showing severe pharyngo-esophageal muscle weakness unresponsive to conventional therapy (corticosteroids and immunosuppressant agents) who were treated with plasma-exchange. As the patients were at high risk of "aspiration pneumonia", tracheostomy and PEG tubes were placed. The patients underwent a series of plasma-exchange for a mean of 15 weeks, during which time they progressively recovered muscle strength, their serum muscle enzyme values returned to normal levels, and MRI showed resolution of muscle edema. The tracheostomy and PEG tubes could be removed. Our findings suggest that plasma-exchange in association with immunosuppressant agents could play a relevant role in the management of dermato/polymyositis in acute phase. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Randomized trial of plasma exchange or high-dosage methylprednisolone as adjunctive therapy for severe renal vasculitis

    National Research Council Canada - National Science Library

    Jayne, DR

    2007-01-01

    .... This study investigated whether the addition of plasma exchange was more effective than intravenous methylprednisolone in the achievement of renal recovery in those who presented with a serum creatinine > 500 mu mol/L (5.8 mg/dl...

  8. Plasma-grafted alkaline anion-exchange membranes based on polyvinyl chloride for potential application in direct alcohol fuel cell

    Science.gov (United States)

    Hu, Jue; Zhang, Chengxu; Cong, Jie; Toyoda, Hirotaka; Nagatsu, Masaaki; Meng, Yuedong

    2011-05-01

    Plasma grafting is employed to prepare alkaline anion-exchange membranes in this study. The attenuated total reflection Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy and thermo gravimetric analysis demonstrate that the benzyltrimethylammonium cationic groups are successfully introduced into the polyvinyl chloride matrix via plasma grafting, quaternization and alkalization. The plasma-grafted alkaline anion-exchange membrane exhibits a satisfactory ionic exchange capacity (1.01 mmol g-1), thermal stability, mechanical property, ionic conductivity (0.0145 S cm-1) and methanol permeability (9.59 × 10-12 m2 s-1), suggesting a great potential for application in direct alcohol fuel cells. The open circuit voltage of air-breathing ADAFC using plasma-grafted alkaline anion-exchange membrane is 0.796 V with 1 M EtOH solution at ambient temperature.

  9. EXCHANGE

    Energy Technology Data Exchange (ETDEWEB)

    Boltz, J.C. (ed.)

    1992-09-01

    EXCHANGE is published monthly by the Idaho National Engineering Laboratory (INEL), a multidisciplinary facility operated for the US Department of Energy (DOE). The purpose of EXCHANGE is to inform computer users about about recent changes and innovations in both the mainframe and personal computer environments and how these changes can affect work being performed at DOE facilities.

  10. Treatment of Goodpasture syndrome with cyclophosphamide, prednisone and plasma exchange transfusions.

    Science.gov (United States)

    Rossen, R D; Duffy, J; McCredie, K B; Reisberg, M A; Sharp, J T; Hersh, E M; Eknoyan, G; Suki, W N

    1976-01-01

    Repeated plasm exchanges were performed in a 44-year-old man with Goodpasture syndrome, also treated with cyclophosphamide and prednisone. Improvement was observed within 3 weeks of starting the protocol, and by the 76th week, endogenous creatinine clearance had increased from 30 to 56 ml/min/1.73 M2 and serum albumin from 2.7 to 3.7 g/dl. Prior treatment with immunosuppressive drugs had not significantly influenced circulating antibody levels. But sustained suppression of antibody was achieved after the plasma exchanges were begun, suggesting that physical removal of circulating antibody combined with antiproliferative drug treatment may be a useful way to control undesirable humoral immune responses. PMID:949874

  11. Long-term outcomes of thrombotic microangiopathy treated with plasma exchange: A systematic review.

    Science.gov (United States)

    Thejeel, Bashiar; Garg, Amit X; Clark, William F; Liu, Aiden R; Iansavichus, Arthur V; Hildebrand, Ainslie M

    2016-06-01

    With the adoption of plasma exchange as standard treatment for thrombotic microangiopathy (TMA), more patients are surviving and long-term outcomes have greater relevance. We conducted a systematic review to synthesize and evaluate the quality of evidence on long-term outcomes of TMA among adults treated with plasma exchange and to identify factors that may be associated with a worse long-term prognosis. We searched databases from 1980 to 2013 for eligible articles published in any language. We included studies that reported outcomes in at least ten adults with a history of TMA treated with plasma exchange and at least 6 months of follow-up. We abstracted data in duplicate and assessed the methodological quality of each study using an assessment tool developed based on recommended validity criteria. We screened 6672 articles, reviewed 213, and included 34 studies totaling 1182 patients (study median [range], 24 [10-118]). The mean (or median) follow-up ranged from 6 months to 13 years. The cumulative incidence of relapse and mortality was highly variable and ranged from 3 to 84 and 0 to 61%, respectively. The incidence of other outcomes across 10 studies also varied (outcomes included hypertension, kidney disease, preeclampsia, stroke, seizure, severe cognitive impairment, and depression); in three other studies, long-term neurocognitive function and health-related quality of life were significantly lower than in the general population. Patients who survive an episode of TMA may be susceptible to long-term vascular complications, but the magnitude of this risk and how to mitigate it remains unclear. Am. J. Hematol. 91:623-630, 2016. © 2016 Wiley Periodicals, Inc.

  12. Is therapeutic plasma exchange indicated for patients with gemcitabine-induced hemolytic uremic syndrome?

    Science.gov (United States)

    Gore, Ethan McCaleb; Jones, Benjamin Scott; Marques, Marisa B

    2009-01-01

    Atypical hemolytic uremic syndrome (aHUS) has been described as an uncommon complication of gemcitabine. In this review, we discuss the diagnosis of gemcitabine-induced aHUS (GiHUS) and the published experience with therapeutic plasma exchange (TPE). To illustrate GiHUS, we present a patient who developed hypertension and peripheral edema while receiving gemcitabine and subsequently was found to have thrombocytopenia, hemolytic anemia, renal failure, and normal ADAMTS-13 activity. Although laboratory parameters improved on suspending gemcitabine, they worsened after reinstitution of the drug. Thrombocytopenia and hemolysis ceased once the drug was permanently discontinued without therapeutic plasma exchange (TPE). The pathological characteristics of GiHUS suggest damage of the glomeruli endothelial lining, leading to occlusion by fibrin-rich thrombi. Among 26 patients described in the literature not treated with TPE, 56% recovered from GiHUS, whereas only 30% of 18 patients treated with TPE did. The difference in recovery rate may have been confounded by the severity of GiHUS as suggested by the rate of dialysis in each group: 10/26 (38%) patients who did not receive TPE were dialyzed compared with 11/18 (61%) of those who had plasma exchange. Thus, although the currently available evidence is not decisive for use or non use of TPE, we suggest that the most important therapeutic intervention in GiHUS is discontinuation of the drug. Apheresis medicine specialists should be aware of this specific type of aHUS and provide treatment advice based on the currently available evidence.

  13. A case of Lewis-Sumner syndrome showing dramatic improvement after plasma exchange.

    Science.gov (United States)

    Park, Young-Eun; Yook, Ji-Won; Kim, Dae-Seong

    2010-07-01

    We report a patient with Lewis-Sumner syndrome (LSS) who showed an improvement only with plasma exchange (PE). The patient, 32-yr old man, had progressive multifocal motor-sensory deficits with persistent, multiple conduction blocks and marked slowing of NCVs. Nerve pathology supported a diagnosis of demyelinating neuropathy by revealing marked loss of myelinated fibers with inter- and intrafascicular variation. Although the patient was refractory to treatment with corticosteroid and intravenous immunoglobulin, PE produced a dramatic improvement. Our experience strongly proposes that PE should be tried for refractory LSS.

  14. [Plasma exchange in treatment refractory septic shock : Presentation of a therapeutic add-on strategy].

    Science.gov (United States)

    David, S; Hoeper, M M; Kielstein, J T

    2017-02-01

    Sepsis is defined as a systemic inflammatory response of the body to an infection. Besides anti-infective drugs and removal of the site of infection, no specific therapeutics that target the overwhelming host response are available. Clinical researchers are currently evaluating the extracorporeal elimination of circulating cytokines. Modern adsorbing techniques have increasingly been used for this purpose allowing an unselective but highly effective removal of the vast majority of circulating cytokines but also fail to replace used protective factors in patients' plasma. Therapeutic plasma exchange (TPE) however might represent a novel method to remove pathologically elevated cytokines and simultaneously to replace protective plasmatic factors. Here we report the case of a septic shock patient treated with TPE and review the available literature with respect to TPE as an adjunctive therapy in sepsis.

  15. Intermittent heterochronic plasma exchange as a modality for delaying cellular senescence-a hypothesis.

    Science.gov (United States)

    Kiprov, Dobri D

    2013-12-01

    The population of baby boomers (age 60-65) is rapidly increasing globally. The aging of the human body is associated with the decline of cellular function which leads to the development of a variety of diseases. The increased demand for health care for the aging population creates significant financial burden to any healthcare system. Developing strategies and health intervention methods to ameliorate this situation is paramount. Experiments utilizing heterochronic parabiosis in mice have demonstrated that replacing the aging cellular milieu with the plasma of a young experimental animal leads to reversal of cellular senescence. This article describes a hypothetical model of intermittent heterochronic plasma exchange in humans as a modality for heterochronic parabiosis in an attempt to delay cellular senescence. Copyright © 2013 Wiley Periodicals, Inc.

  16. Silenced uses and moral ideals in the exchange of Danish blood and plasma

    DEFF Research Database (Denmark)

    Sheikh, Zainab Afshan; Deleuran, Ida; Hoeyer, Klaus

    2016-01-01

    This article explores the interplay between cultural discourses, moral reasoning and silenced uses in the international exchange of Danish blood plasma. Campaigns, policymakers, health professionals working in the blood banks – and even donors – consistently refer to ideals portraying blood....... However, we find that available cultural discourses poorly capture the moral reasoning among many donors. In fact, when informed about the existing forms of tender, plasma trade sounds like a good idea to most of them. Furthermore, they are not particularly interested in information. We argue...... that the silencing of trade is infusing the system with an unnecessary vulnerability that could easily be avoided with a different communication strategy towards donors. To arrive at new and better strategies, however, one must move beyond the immediate words and reactions of donors contemplating trade and seek...

  17. Plasma exchange and chlorambucil in polyneuropathy associated with monoclonal IgM gammopathy. IgM-associated Polyneuropathy Study Group.

    Science.gov (United States)

    Oksenhendler, E; Chevret, S; Léger, J M; Louboutin, J P; Bussel, A; Brouet, J C

    1995-01-01

    The study compared chlorambucil alone with chlorambucil in combination with plasma exchange in patients with polyneuropathy associated with monoclonal IgM. Forty four patients were prospectively randomly assigned, in a comparative open trial, to receive either 0.1 mg/kg/day chlorambucil orally, for 12 months or chlorambucil associated with 15 courses of plasma exchange, during the first four months of treatment. They were evaluated by a neuropathy disability score and nerve conduction studies. No difference was found between the two treatment groups. The average neuropathy disability score improved by 2.1 points from baseline (21.0 to 18.9) in the chlorambucil group and by 1.8 points (20.4 to 18.6) in the chlorambucil + plasma exchange group (P = 0.70). The mean motor nerve conduction velocity decreased from 20.0 to 18.2 m/s in the chlorambucil group and increased from 20.5 to 22.5 m/s in the chlorambucil + plasma exchange group (P = 0.51). A slight improvement of the sensory component of the neuropathy disability score (from 10.5 to 8.3) was noted in both groups (P = 0.01). At the end of the study and according to self evaluation, 15 patients--eight from the chlorambucil group and seven from the chlorambucil + plasma exchange group--reported clinical improvement, whereas 15--eight from the chlorambucil group and seven from the chlorambucil + plasma exchange group--reported clinical worsening. Neuropathy remained stable in the others. Thus plasma exchange seemed to confer no additional benefit in the treatment of polyneuropathy associated with monoclonal IgM. PMID:7673949

  18. The Plasma Membrane Ca2+ ATPase and the Plasma Membrane Sodium Calcium Exchanger Cooperate in the Regulation of Cell Calcium

    Science.gov (United States)

    Brini, Marisa; Carafoli, Ernesto

    2011-01-01

    Calcium is an ambivalent signal: it is essential for the correct functioning of cell life, but may also become dangerous to it. The plasma membrane Ca2+ ATPase (PMCA) and the plasma membrane Na+/Ca2+ exchanger (NCX) are the two mechanisms responsible for Ca2+ extrusion. The NCX has low Ca2+ affinity but high capacity for Ca2+ transport, whereas the PMCA has a high Ca2+ affinity but low transport capacity for it. Thus, traditionally, the PMCA pump has been attributed a housekeeping role in maintaining cytosolic Ca2+, and the NCX the dynamic role of counteracting large cytosolic Ca2+ variations (especially in excitable cells). This view of the roles of the two Ca2+ extrusion systems has been recently revised, as the specific functional properties of the numerous PMCA isoforms and splicing variants suggests that they may have evolved to cover both the basal Ca2+ regulation (in the 100 nM range) and the Ca2+ transients generated by cell stimulation (in the μM range). PMID:21421919

  19. The results of therapeutic plasma exchange in patients with severe hyperthyroidism: a retrospective multicenter study.

    Science.gov (United States)

    Keklik, Muzaffer; Kaynar, Leylagul; Yilmaz, Mehmet; Sivgin, Serdar; Solmaz, Musa; Pala, Cigdem; Aribas, Sulbiye; Akyol, Gulsah; Unluhizarci, Kursat; Cetin, Mustafa; Eser, Bulent; Unal, Ali

    2013-06-01

    Hyperthyroidism characterized by elevated serum levels of circulating thyroid hormones. The aim of hyperthyroidism treatment is to achieve a euthyroid state as soon as possible and to maintain euthyroid status. However, drug withdrawal and utilization of alternative therapies are needed in cases in which leucopenia or impairment in liver functions is observed during medical therapy. In the present study, we aimed to present our cases which underwent therapeutic plasma exchange (TPE) due to severe hyperthyroidism. The results of 22 patients who underwent therapeutic plasma exchange due to hyperthyroidism in Apheresis Units of Erciyes University and Gaziantep University, between 2006 and 2012, were retrospectively reviewed. These cases had severe thyrotoxic values despite anti-thyroid drug use. After TPE, we observed a significant decrease in free thyroxin (FT4) (phyperthyroidism by TPE in 20 cases (91%). Both FT3 and FT4 levels remained above the normal limits in two of 22 patients. TPE should be considered as an effective and safe therapeutic option to achieve euthyroid state before surgery or radioactive iodine treatment. TPE is a useful option in cases with severe hyperthyroidism unresponsive to anti-thyroid agents and in those with clinical manifestations of cardiac failure and in patients with severe adverse events during anti-thyroid therapy.

  20. Diffusion, trapping, and isotope exchange of plasma implanted deuterium in ion beam damaged tungsten

    Science.gov (United States)

    Barton, Joseph Lincoln

    Tritium accumulation in nuclear fusion reactor materials is a major concern for practical and safe fusion energy. This work examines hydrogen isotope exchange as a tritium removal technique, analyzes the effects of neutron damage using high energy copper ion beams, and introduces a diffusion coefficient that is a function of the concentration of trapped atoms. Tungsten samples were irradiated with high energy (0.5 - 5 MeV) copper ions for controlled levels of damage - 10-3 to 10-1 displacements per atom (dpa) - at room temperature. Samples were then exposed to deuterium plasma at constant temperature (˜ 380 K) to a high fluence of 1024 ions/m2, where retention is at is maximized (i.e. saturated). By then subsequently exposing these samples to fractions of this fluence with hydrogen plasma, isotope exchange rates were observed. The resulting deuterium still trapped in the tungsten is then measured post mortem. Nuclear reaction analysis (NRA) gives the depth resolved deuterium retention profile with the 3He(D,p) 4He reaction, and thermal desorption spectroscopy (TDS) gives the total amount of deuterium trapped in the tungsten by heating a sample in vacuum up to 1200 K and measuring the evaporated gas molecules with a residual gas analyzer. Isotope exchange data show that hydrogen atoms can displace trapped deuterium atoms efficiently only up to the first few microns, but does not affect the atoms trapped at greater depths. In ion damaged tungsten, measurements showed a significant increase in retention in the damage region proportional to dpa 0.66, which results in a significant spike in total retention, and isotope exchange in damaged samples is still ineffective at depths greater than a few microns. Thus, isotope exchange is not an affective tritium removal technique; however, these experiments have shown that trapping in material defects greatly affects diffusion. These experiments lead to a simplified diffusion model with defect densities as the only free

  1. X-ray spectroscopic study of charge exchange phenomena in plasma-wall interaction

    Directory of Open Access Journals (Sweden)

    Renner O.

    2013-11-01

    Full Text Available Jets of energetic ions launched at laser-burnt-through foils represent an efficient tool for investigation of plasma interaction with solid surfaces (plasma-wall interaction, PWI and for description of transient phenomena occurring close to the walls. Highly charged ions approaching the secondary target interpenetrate the near surface layer, collide with the counter-propagating matter and capture a large number of electrons. This results in a creation of atoms in highly excited Rydberg states or hollow ions with multiple inner vacancies; plasma jet and target ions may also undergo charge exchange (CE processes. We report PWI experiments with Al/Si(PMMA and Al/C targets irradiated at normal or oblique laser incidence. The distinct dip structures observed in red wings of Al Lyγ self-emission is interpreted in terms of CE between C6+ and Al12+ in the near-wall zone. The spectroscopic identification of CE phenomena is supported by results of analytical and numerical calculations.

  2. Combination therapy with mitoxantrone and plasma exchange in aggressive relapsing remitting multiple sclerosis: A preliminary clinical study

    Directory of Open Access Journals (Sweden)

    Nasim Tabrizi

    2012-01-01

    Full Text Available Background: The efficacy of mitoxantrone induction therapy in rapidly worsening multiple sclerosis (MS is well established. Plasma exchange is also applied as an adjuvant in exacerbations of relapsing MS. The aim of this study was to compare the efficacy of combination therapy with mitoxantrone and plasma exchange versus mitoxantrone alone in patients with aggressive MS. Materials and Methods: Forty patients with aggressive relapsing remitting MS were randomly put into two groups. The first group underwent monthly plasma exchange for three successive months, followed by 12 mg/m 2 mitoxantrone at the end of each course and two more doses of 6 mg/m 2 mitoxantrone in 3-month intervals. The second group received the same doses of mitoxantrone only without plasma exchange. At the end of 8 months treatment course, clinical reassessment and neuroimaging was performed and treatment was continued with interferon-β. Results: At the end of induction therapy, Expanded Disability Status Scale score was significantly improved in both groups (P < 0.001. Number of demyelinating and gadolinium-enhancing plaques in brain magnetic resonance imaging (MRI was prominently reduced in group 2 (P ≤ 0.05, but the changes were not statistically significant in group 1, except for juxtacortical plaques. Conclusion: Administration of mitoxantrone as an induction therapy in patients of aggressive relapsing remitting MS results in significant improvement of their clinical state and MRI activity. However, combination of plasma exchange with mitoxantrone gives no more benefits than mitoxantrone alone and sometimes worsens the situation possibly by reduction of mitoxantrone efficacy as a result of plasma exchange.

  3. Study of plasma off-gas treatment from spent ion exchange resin pyrolysis.

    Science.gov (United States)

    Castro, Hernán Ariel; Luca, Vittorio; Banchi, Hugo Luis

    2017-03-23

    Polystyrene divinylbenzene-based ion exchange resins are employed extensively within nuclear power plants (NPPs) and research reactors for purification and chemical control of the cooling water system. To maintain the highest possible water quality, the resins are regularly replaced as they become contaminated with a range of isotopes derived from compromised fuel elements as well as corrosion and activation products including (14)C, (60)Co, (90)Sr, (129)I, and (137)Cs. Such spent resins constitute a major proportion (in volume terms) of the solid radioactive waste generated by the nuclear industry. Several treatment and conditioning techniques have been developed with a view toward reducing the spent resin volume and generating a stable waste product suitable for long-term storage and disposal. Between them, pyrolysis emerges as an attractive option. Previous work of our group suggests that the pyrolysis treatment of the resins at low temperatures between 300 and 350 °C resulted in a stable waste product with a significant volume reduction (>50%) and characteristics suitable for long-term storage and/or disposal. However, another important issue to take into account is the complexity of the off-gas generated during the process and the different technical alternatives for its conditioning. Ongoing work addresses the characterization of the ion exchange resin treatment's off-gas. Additionally, the application of plasma technology for the treatment of the off-gas current was studied as an alternative to more conventional processes utilizing oil- or gas-fired post-combustion chambers operating at temperatures in excess of 1000 °C. A laboratory-scale flow reactor, using inductively coupled plasma, operating under sub-atmospheric conditions was developed. Fundamental experiments using model compounds have been performed, demonstrating a high destruction and removal ratio (>99.99%) for different reaction media, at low reactor temperatures and moderate power

  4. Charge exchange between two nearest neighbour ions immersed in a dense plasma

    Science.gov (United States)

    Sauvan, P.; Angelo, P.; Derfoul, H.; Leboucher-Dalimier, E.; Devdariani, A.; Calisti, A.; Talin, B.

    1999-04-01

    In dense plasmas the quasimolecular model is relevant to describe the radiative properties: two nearest neighbor ions remain close to each other during a time scale of the order of the emission time. Within the frame of a quasistatic approach it has been shown that hydrogen-like spectral line shapes can exhibit satellite-like features. In this work we present the effect on the line shapes of the dynamical collision between the two ions exchanging transiently their bound electron. This model is suitable for the description of the core, the wings and the red satellite-like features. It is post-processed to the self consistent code (IDEFIX) giving the adiabatic transition energies and the oscillator strengths for the transient molecule immersed in a dense free electron bath. It is shown that the positions of the satellites are insensitive to the dynamics of the ion-ion collision. Results for fluorine Lyβ are presented.

  5. Plasma-exchange in the treatment of systemic rheumatic diseases: past and present experience

    Directory of Open Access Journals (Sweden)

    P. Marson

    2011-06-01

    Full Text Available La terapia con plasma-exchange (PEx è stata utilizzata sin dagli anni Settanta per la cura di molteplici malattie, nella cui patogenesi fattori umorali si riteneva potessero giocare un ruolo di rilievo. Questa modalità di trattamento comporta la rimozione di autoanticorpi, immunocomplessi circolanti, molecole di adesione, citochine, chemochine ed altri mediatori solubili implicati nello sviluppo del danno tissutale (1. Nel 1993 l’American Society of Apheresis (ASFA ha per la prima volta pubblicato un elenco di applicazioni cliniche delle diverse tecniche di aferesi terapeutica, fra le quali di gran lunga la più utilizzata era, allora come oggi, il PEx (2. Questo elenco comprendeva malattie autoimmuni, malattie ematologiche ed oncologiche, disordini metabolici, malattie neurologiche e malattie renali. Fra le malattie autoimmuni figuravano molte forme morbose di pertinenza reumatologica...

  6. Plasma Sprayed Ni-Al Coatings for Safe Ending Heat Exchanger Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Allen, M.L.; Berndt, C.C.; Otterson, D.

    1998-11-01

    Brookhaven National Laboratory (BNL) has developed thermally conductive composite liners for corrosion and scale protection in heat exchanger tubes exposed to geothermal brine. The liners cannot withstand roller expansion to connect the tubes to the tubesheet. It is not possible to line the ends of the tubes with the same material after roller expansion due to the nature of the current liner application process. It was requested that BNL evaluate plasma sprayed Ni-Al coatings for safe ending heat exchanger tubes exposed to geothermal brine. The tubes of interest had an internal diameter of 0.875 inches. It is not typical to thermal spray small diameter components or use such small standoff distances. In this project a nozzle extension was developed by Zatorski Coating Company to spray the tube ends as well as flat coupons for testing. Four different Ni-Al coatings were investigated. One of these was a ductilized Ni-AlB material developed at Oak Ridge National Laboratory. The coatings were examined by optical and scanning electron microscopy. In addition, the coatings were analyzed by X-ray diffraction and subjected to corrosion, tensile adhesion, microhardness and field tests in a volcanic pool in New Zealand.

  7. Plasma-induced Styrene Grafting onto the Surface of Polytetrafluoroethylene Powder for Proton Exchange Membrane Application%Plasma-induced Styrene Grafting onto the Surface of Polytetrafluoroethylene Powder for Proton Exchange Membrane Application

    Institute of Scientific and Technical Information of China (English)

    兰彦; 程诚; 张素贞; 倪国华; 陈龙威; 杨光杰; M.NAGATSU; 孟月东

    2011-01-01

    Low-temperature plasma treatment was adopted to graft styrene onto polytetrafluo- roethylene (PTFE) powder, which is widely used in the fabrication of proton exchange membrane (PEM). The grafted PTFE powder was sulfonated in chlorosulfonic acid and fabricated into a membrane, which was used as inexpensive PEM material for a proton exchange membrane fuel cell (PEMFC). Fourier transform infrared spectroscopy attenuated total reflection spectroscopy (FTIR-ATR) and X-ray photoelectron spectroscopy (XPS) analysis were used to characterize the structure of the sulfonated PTFE powder. The results showed that all the PTFE powders were successfully grafted by nitrogen plasma and then sulfonated under such experimental conditions. A scanning electron microscopy (SEM) image indicated that the fabricated membrane exhibits flat morphology and homogenous structure. The ion exchange capacity (IEC) of this kind of PEM was also investigated.

  8. Treatment of spent ion-exchange resins in shaft-type reactor with fuel-plasma source of heating

    Energy Technology Data Exchange (ETDEWEB)

    Dmitriev, S. A.; Knyazev, I. A.; Lifanov, F. A.; Polkanov, M. A.; Shvetsov, S. Yu; Savkin, A. E. [Moscow Scientific and Industrial Association RADON, Moscow (Russian Federation)

    1999-07-01

    The method of high-temperature conditioning the spent radioactive ion-exchange resins in combination with other combustible and incombustible radioactive waste in the plasma shaft furnace with obtaining a crystalline glass-like matrix as a final product has been developed. The method was tested on the pilot plant consisted of ceramic plasma melter, steel water-cooled shaft furnace, lined by fire-resistant concrete, and system of gas purification. The capacity of the furnace was within the limits from 10 to 15 kg/h. The volume and mass reduction factors of treated waste were 36 and 7.6, accordingly. The content of gaseous products of thermal decomposition of a waste at an output of the shaft furnace and properties of obtained slag compound were determined. Based on test results the proposals on creation of compact plasma plant for treatment of mixed radioactive waste including spent ion exchange resins were developed. (author). 3 refs., 2 tabs., 2 figs.

  9. Ion-exchange chromatography used to isolate a spermadhesin-related protein from domestic goat (Capra hircus) seminal plasma.

    Science.gov (United States)

    Teixeira, Dárcio Italo Alves; Melo, Luciana Magalhães; Gadelha, Carlos Alberto de Almeida; Cunha, Rodrigo Maranguape Silva da; Bloch, Carlos; Rádis-Baptista, Gandhi; Cavada, Benildo Sousa; Freitas, Vicente José de Figueirêdo

    2006-03-31

    Mammalian seminal plasma contains among others, proteins called spermadhesins, which are the major proteins of boar and stallion seminal plasma. These proteins appear to be involved in capacitation and sperm-egg interaction. Previously, we reported the presence of a protein related to spermadhesins in goat seminal plasma. In the present study, we have further characterized this protein, and we propose ion-exchange chromatography to isolate this seminal protein. Semen was obtained from four adult Saanen bucks. Seminal plasma was pooled, dialyzed against distilled water and freeze-dried. Lyophilized proteins were loaded onto an ion-exchange chromatography column. Dialyzed-lyophilized proteins from the main peak of DEAE-Sephacel were applied to a C2/C18 column coupled to an RP-HPLC system, and the eluted proteins were lyophilized for electrophoresis. The N-terminal was sequenced and amino acid sequence similarity was determined using CLUSTAL W. Additionally, proteins from DEAE-Sephacel chromatography step were dialyzed and submitted to a heparin-Sepharose high-performance liquid chromatography. Goat seminal plasma after ion-exchange chromatography yielded 6.47 +/- 0.63 mg (mean +/- SEM) of the major retained fraction. The protein was designated BSFP (buck seminal fluid protein). BSFP exhibited N-terminal sequence homology to boar, stallion and bull spermadhesins. BSFP showed no heparin-binding capabilities. These results together with our previous data indicate that goat seminal plasma contains a protein that is structurally related to proteins of the spermadhesin family. Finally, this protein can be efficiently isolated by ion-exchange and reverse-phase chromatography.

  10. PLASMA SPRAYED Ni-Al COATINGS FOR SAFE ENDING HEAT EXCHANGER TUBES

    Energy Technology Data Exchange (ETDEWEB)

    ALLAN,M.L.; OTTERSON,D.; BERNDT,C.C.

    1998-11-01

    Brookhaven National Laboratory (BNL) has developed thermally conductive composite liners for corrosion and scale protection in heat exchanger tubes exposed to geothermal brine. The liners cannot withstand roller expansion to connect the tubes to the tubesheet. It is not possible to line the ends of the tubes with the same material after roller expansion due to the nature of the current liner application process. It was requested that BNL evaluate plasma sprayed Ni-Al coatings for safe ending heat exchanger tubes exposed to geothermal brine. The tubes of interest had an internal diameter of 0.875 inches. It is not typical to thermal spray small diameter components or use such small standoff distances. In this project a nozzle extension was developed by Zatorski Coating Company to spray the tube ends as well as flat coupons for testing. Four different Ni-Al coatings were investigated. One of these was a ductilized Ni-AIB material developed at Oak Ridge National Laboratory. The coatings were examined by optical and scanning electron microscopy. In addition, the coatings were analyzed by X-ray diffraction and subjected to corrosion, tensile adhesion, microhardness and field tests in a volcanic pool in New Zealand. It was determined that the Ni-Al coatings could be applied to a depth of two inches on the tube ends. When sprayed on flat coupons the coatings exhibited relatively high adhesion strength and microhardness. Polarization curves showed that the coating performance was variable. Measured corrosion potentials indicated that the Ni-Al coatings are active towards steel coated with thermally conductive polymers, thereby suggesting preferential corrosion. Corrosion also occurred on the coated coupons tested in the volcanic pool. This may have been exacerbated by the difficulty in applying a uniform coating to the coupon edges. The Ni-Al coatings applied to the tubes had significant porosity and did not provide adequate corrosion protection. This is associated with

  11. Therapeutic plasma exchange in antisynthetase syndrome with severe interstitial lung disease.

    Science.gov (United States)

    Omotoso, Bolanle A; Ogden, Melissa I; Balogun, Rasheed A

    2015-12-01

    Antisynthetase syndrome (ASS) is a rare condition characterized by interstitial lung disease (ILD), inflammatory myositis, fever, Raynaud phenomenon, mechanic's hand, and inflammatory polyarthritis in the setting of antibodies to amino acyl-transfer RNA synthetases, with anti-Jo-1 antibody being the most common. Prognosis is very poor especially when there is associated ILD. To date, there is no standardized treatment for ILD associated ASS. Therapy is based on the use of steroids alone or in combination with other immunosuppressive agents, especially in severe or refractory cases. The role of therapeutic plasma exchange (TPE) in the management of this rare condition has not been established. Here, we report a case of severe ILD associated ASS in a 41-year-old woman who did not show clinical or laboratory response after six doses of high dose steroids and a dose of IV cyclophosphamide. Because of the aggressive nature of her disease and poor prognostic indices present, a decision was made to add TPE to her treatment. She underwent five sessions of TPE. At the end of the 5th session, the anti-Jo-1 antibody levels dropped to 3.6 AI (antibody index) and her creatinine kinase (CK) level from 875 to 399 U L(-1) (Units per liter) with overall improvement in her respiratory status. This case suggests TPE may be a promising treatment option in patients with ILD associated ASS refractory to steroids and other immunosuppressive therapy, particularly those with severe disease.

  12. Immunoglobulin M 'Flare' Seen in a Case of Waldenstrom's Macroglobulinemia: Successfully Managed by Therapeutic Plasma Exchange.

    Science.gov (United States)

    Datta, Suvro Sankha; Mukherjee, Somnath; Talukder, Biplabendu; Bhattacharya, Prasun

    2016-06-01

    Therapeutic plasma exchange (TPE) is a conjunctive modality of treatment along with rituximab to decrease paraproteinemia associated with hyperviscosity. Here we narrate our experience in treating a diagnosed case of Waldenstrom's macroglobulinemia in 70 years old male patient with moderate anemia and severe features of hyperviscosity syndrome by serial TPE and rituximab combined with bortezomib. The patient was relieved of his symptoms after initial two TPE procedures performed on alternative day. However he again developed signs and symptoms of the disease within 6 weeks following second TPE and starting of rituximab (375 mg/m(2) weekly for 4 weeks) therapy with bortezomib. His serum IgM level became as high as 9.901 g/dl suggesting immunoglobulin M 'Flare' due to rituximab therapy. At the end of third TPE he was relieved symptomatically with low IgM level (3.13 g/dl) and discharged in hemodynamically stable condition. Therefore we concluded that careful monitoring of serum viscosity and IgM level are necessary during treatment with rituximab based chemotherapy and TPE should be promptly initiated to control the treatment related hyperviscosity syndrome.

  13. Immune tolerance induced using plasma exchange and rituximab in an infantile Pompe disease patient.

    Science.gov (United States)

    Deodato, Federica; Ginocchio, Virginia Maria; Onofri, Alfredo; Grutter, Giorgia; Germani, Alessandro; Dionisi-Vici, Carlo

    2014-06-01

    Infantile Pompe disease, resulting from deficiency of lysosomal acid α-glucosidase, requires enzyme replacement therapy with recombinant human acid α-glucosidase. Most patients develop antirecombinant human acid α-glucosidase antibodies, leading to reduced response to enzyme therapy in a subgroup of them. Aiming to improve treatment response, several immune tolerance induction strategies have been explored. We describe a patient with life-threatening infusion-associated reactions presenting anti-recombinant human acid α-glucosidase antibodies. He was successfully treated with an immune tolerance induction protocol, consisting of plasma exchange combined with a single dose of rituximab. Immediate reduction of antibody titer was obtained and enzyme therapy was resumed without infusion-associated reactions. Twenty-two months later, immunoglobulin G titer remained below 1:100. In conclusion, we applied a short-course immune tolerance induction strategy in a patient with severe infusion-associated reactions and anti-recombinant human acid α-glucosidase antibodies, leading to early and persisting reduction of antibody titer, in the absence of significant adverse events.

  14. Plasma exchange in Goodpasture syndrome associated with Turner's syndrome: A case report.

    Science.gov (United States)

    Jiao, L P; Fan, J F; Sun, Q; Shen, Y

    2012-12-01

    Good pasture syndrome (GPS) has been paid much attention recently for the dangerous illness and high mortality. To investigate the efficiency of plasma exchange (PE) to treat Goodpasture syndrome (GPS) in children associated with Turner's syndrome. We report a case of a 15 year old female with GPS and Turner's syndrome. The patient has intermittent fever and cough for 45 days and oliguria for 6 days. Turner's syndrome was determined through blood karyotype analysis, and GPS was diagnosed because the patient was negative for antinuclear antibodies and antineutrophil cytoplasmic antibodies (ANCA), but positive for anti-glomerular basement membrane (anti-GBM) antibodies (200 RU/ml). PE was carried out in combination with immunosuppression therapy. The results show PE treatment can efficiently decrease the levels of anti-GBM antibodies. The antibody levels were >200 RU/ml and 184 RU/ml before and after the first PE treatment, respectively. The removal efficiency were 40%, 47%, 42%, 54%, 52% for the fifth, sixth, seventh, eighth and ninth PE procedures, respectively. The therapy with PE, hemodialysis, pulse methylprednisolone followed by oral prednisone and cyclophosphamide greatly contributed to improvement of this patient's condition, and resolved the patient's pulmonary haemorrhage. All these results demonstrate that PE contributed efficiently to the treatment for GPS in children.

  15. Plasma exchange treatment for acute hyperlipidemic pancreatitis with falsely low levels of serum triglycerides - a case report.

    Science.gov (United States)

    Markota, A; Knehtl, M; Sinkovic, A; Ekart, R; Hojs, R; Bevc, S

    2014-10-01

    Hypertriglyceridemia is a well-recognized cause of acute pancreatitis. We present a patient with acute hypertriglyceridemic pancreatitis. At presentation serum triglycerides were severely elevated (104 mmol/l) and were decreasing the next day (11 mmol/l). However, based on increasing levels of serum lipase, worsening respiratory failure and evidently lipemic serum, we decided to perform plasma exchange, and patient's condition improved dramatically. Repeated laboratory test of the serum obtained before the first plasma exchange revealed that the actual value of serum triglycerides was 57 mmol/l. A clinically-driven decision is crucial when treating patients with hypertriglyceridemic acute pancreatitis as the serum triglyceride levels can be falsely low.

  16. Guillain - Barre syndrome in a patient with acute myocardial infarction with ventricular septal defect repair treated with plasma exchange

    Directory of Open Access Journals (Sweden)

    Maitrey D Gajjar

    2015-01-01

    Full Text Available Guillain - Barre syndrome (GBS is an acute, frequently severe progressive illness of peripheral nervous system that is autoimmune in nature. GBS after myocardial infarction (MI with ventricular septal defect (VSD is uncommon with high mortality rate if not treated promptly. [1] We report a successful outcome of GBS post MI with VSD in a 60-year-old male patient who was on a ventilator treated successfully with therapeutic plasma exchange.

  17. Anti-GBM of Pregnancy: Acute Renal Failure Resolved after Spontaneous Abortion, Plasma Exchange, Hemodialysis, and Steroids

    OpenAIRE

    Mohammed Muqeet Adnan; Jordan Morton; Syed Hashmi; Sufyan Abdul Mujeeb; William Kern; Benjamin Jr. Cowley

    2014-01-01

    Antiglomerular basement membrane disease presenting during pregnancy is very uncommon. We present a case of a pregnant female who presented with acute renal failure needing dialysis from Goodpasture's disease. She responded very well to just plasma exchange, high dose steroids, and hemodialysis. Cyclophosphamide was never started on this patient. She had a spontaneous abortion in her 8th week of pregnancy and henceforth did very well to regain her renal function. Patient became hemodialysis i...

  18. The contribution of the sodium-calcium exchanger (NCX) and plasma membrane Ca(2+) ATPase (PMCA) to cerebellar synapse function.

    Science.gov (United States)

    Roome, Chris J; Empson, Ruth M

    2013-01-01

    The cerebellum, a part of the brain critically involved in motor learning and sensory adaptation, expresses high levels of the sodium-calcium exchanger (NCX) and the plasma membrane calcium ATPase (PMCA). Both these transporters control calcium dynamics at a variety of synapses, and here, we draw upon the available literature to discuss how NCX and PMCA work together to shape pre-synaptic calcium dynamics at cerebellar synapses.

  19. Treatment of acute relapses in neuromyelitis optica: Steroids alone versus steroids plus plasma exchange.

    Science.gov (United States)

    Abboud, Hesham; Petrak, Alex; Mealy, Maureen; Sasidharan, Sarana; Siddique, Laila; Levy, Michael

    2016-02-01

    Although adding plasma exchange (PLEX) to steroids in severe neuromyelitis optica (NMO) attacks is common practice in steroid-resistant cases, the benefit of this strategy has not been previously quantified. The objective of this paper is to compare the efficacy of high-dose intravenous methylprednisolone (IVMP) versus IVMP+PLEX in treatment of acute NMO relapses. We conducted a retrospective review of the last 83 NMO admissions to the Johns Hopkins Hospital treated with IVMP alone versus IVMP+PLEX (for steroid-resistant cases). Extended Disability Status Scale (EDSS) score was calculated at baseline, at presentation, at discharge, and on follow-up. Eighteen NMO relapses (16 patients, 87% female, mean age at relapse: 33.9±23.8, median baseline EDSS 2.5) were treated with IVMP alone and 65 relapses (43 patients, 95% female, mean age at relapse: 43.8±15.7, median baseline EDSS 5.75) were treated with IVMP + PLEX. Sixty-five percent of IVMP + PLEX patients achieved an EDSS equal or below their baseline at follow-up while only 35% of the IVMP-only patients achieved their baseline EDSS on follow-up (odds ratio=3.36, 95% CI 1.0657 to 10.6004, p = 0.0386). PLEX was more effective in improving EDSS in patients on preventive immunosuppressive medications at time of relapse. PLEX+IVMP are more likely to improve EDSS after NMO relapses compared to IVMP alone, especially in patients taking preventive medications. © The Author(s), 2015.

  20. Factors associated with the effectiveness of plasma exchange for the treatment of NMO-IgG-positive neuromyelitis optica spectrum disorders.

    Science.gov (United States)

    Lim, Young-Min; Pyun, So Young; Kang, Bong-Hui; Kim, Jimin; Kim, Kwang-Kuk

    2013-08-01

    To identify factors associated with plasma exchange response in neuromyelitis optica (NMO) spectrum disorders, the clinical and magnetic resonance imaging (MRI) features of 31 NMO-IgG-positive patients receiving plasma exchange for steroid-resistant exacerbations were analyzed. Functional improvement was observed in 65% of the patients. A lower baseline Expanded Disability Status Scale score was associated with favorable response (p = 0.040). Patients without cord atrophy had a higher success rate than patients with atrophy (p = 0.016). Levels of NMO-IgG did not differ between responders and non-responders before and after plasma exchange. In conclusion, a minimal pre-existing disability is the primary determinant of the effectiveness of plasma exchange.

  1. X-ray and EUV spectroscopy of various astrophysical and laboratory plasmas -- Collisional, photoionization and charge-exchange plasmas

    CERN Document Server

    Liang, G Y; Wang, F L; Wu, Y; Zhong, J Y; Zhao, G

    2014-01-01

    Several laboratory facilities were used to benchmark theoretical spectral models those extensively used by astronomical communities. However there are still many differences between astrophysical environments and laboratory miniatures that can be archived. Here we setup a spectral analysis system for astrophysical and laboratory (SASAL) plasmas to make a bridge between them, and investigate the effects from non-thermal electrons, contribution from metastable level-population on level populations and charge stage distribution for coronal-like, photoionized, and geocoronal plasmas. Test applications to laboratory measurement (i.e. EBIT plasma) and astrophysical observation (i.e. Comet, Cygnus X-3) are presented. Time evolution of charge stage and level population are also explored for collisional and photoionized plasmas.

  2. Inositol phospholipids regulate the guanine-nucleotide-exchange factor Tiam1 by facilitating its binding to the plasma membrane and regulating GDP/GTP exchange on Rac1.

    Science.gov (United States)

    Fleming, Ian N; Batty, Ian H; Prescott, Alan R; Gray, Alex; Kular, Gursant S; Stewart, Hazel; Downes, C Peter

    2004-09-15

    Binding of the Rac1-specific guanine-nucleotide-exchange factor, Tiam1, to the plasma membrane requires the N-terminal pleckstrin homology domain. In the present study, we show that membrane-association is mediated by binding of PtdIns(4,5)P(2) to the pleckstrin homology domain. Moreover, in 1321N1 astrocytoma cells, translocation of Tiam1 to the cytosol, following receptor-mediated stimulation of PtdIns(4,5)P(2) breakdown, correlates with decreased Rac1-GTP levels, indicating that membrane-association is required for GDP/GTP exchange on Rac1. In addition, we show that platelet-derived growth factor activates Rac1 in vivo by increasing PtdIns(3,4,5)P(3) concentrations, rather than the closely related lipid, PtdIns(3,4)P(2). Finally, the data demonstrate that PtdIns(4,5)P(2) and PtdIns(3,4,5)P(3) bind to the same pleckstrin homology domain in Tiam1 and that soluble inositol phosphates appear to compete with lipids for this binding. Together, these novel observations provide strong evidence that distinct phosphoinositides regulate different functions of this enzyme, indicating that local concentrations of signalling lipids and the levels of cytosolic inositol phosphates will play crucial roles in determining its activity in vivo.

  3. Severe Uncompensated Metabolic Alkalosis due to Plasma Exchange in a Patient with Pulmonary-Renal Syndrome: A Clinician’s Challenge

    Directory of Open Access Journals (Sweden)

    Mohsin Ijaz

    2015-01-01

    Full Text Available Metabolic alkalosis secondary to citrate toxicity from plasma exchange is very uncommon in patients with normal renal function. In patients with advanced renal disease this can be a fatal event. We describe a case of middle-aged woman with Goodpasture’s syndrome treated with plasma exchange who developed severe metabolic alkalosis. High citrate load in plasma exchange fluid is the underlying etiology. Citrate metabolism generates bicarbonate and once its level exceeds the excretory capacity of kidneys, the severe metabolic alkalosis ensues. Our patient presented with generalized weakness, fever, and oliguria and developed rapidly progressive renal failure. Patient had positive serology for antineutrophilic cytoplasmic antibodies myeloperoxidase (ANCA-MPO and anti-glomerular basement membrane antibodies (anti-GBM. Renal biopsy showed diffuse necrotizing and crescentic glomerulonephritis with linear glomerular basement membrane staining. Patient did not respond to intravenous steroids. Plasma exchange was started with fresh frozen plasma but patient developed severe metabolic alkalosis. This metabolic alkalosis normalized with cessation of plasma exchange and initiation of low bicarbonate hemodialysis. ANCA-MPO and anti-GBM antibodies levels normalized within 2 weeks and remained undetectable at 3 months. Patient still required maintenance hemodialysis.

  4. Successful treatment of severe myasthenia gravis developed after allogeneic hematopoietic stem cell transplantation with plasma exchange and rituximab.

    Science.gov (United States)

    Unal, Sule; Sag, Erdal; Kuskonmaz, Baris; Kesici, Selman; Bayrakci, Benan; Ayvaz, Deniz C; Tezcan, Ilhan; Yalnızoglu, Dilek; Uckan, Duygu

    2014-05-01

    Myasthenia gravis is among the rare complications after allogeneic hematopoietic stem cell transplantation and is usually associated with chronic GVHD. Herein, we report a 2-year and 10 months of age female with Griscelli syndrome, who developed severe myasthenia gravis at post-transplant +22nd month and required respiratory support with mechanical ventilation. She was unresponsive to cyclosporine A, methylprednisolone, intravenous immunoglobulin, and mycophenolate mofetil and the symptoms could only be controlled after plasma exchange and subsequent use of rituximab, in addition to cyclosporine A and mycophenolate mofetil maintenance. She is currently asymptomatic on the 6th month of follow-up.

  5. Possible role for exchange plasmapheresis with fresh frozen plasma for maternal indications in selected cases of preeclampsia and eclampsia.

    Science.gov (United States)

    Schwartz, M L

    1986-07-01

    A new case of a preeclamptic who developed the diagnostic criteria for the hemolytic uremic syndrome and who was treated with plasmapheresis is presented. Fourteen case reports of gravidas with preeclampsia treated by exchange plasmapheresis with fresh frozen plasma for maternal indications are reviewed. Only four cases had been reported as eclampsia or preeclampsia. The other cases had been reported as thrombotic thrombocytopenic purpura, the postpartum hemolytic uremic syndrome, or fatty liver of pregnancy. The possible role of plasmapheresis in treating very carefully selected cases of preeclampsia is discussed.

  6. Maintenance of kidney function following treatment with eculizumab and discontinuation of plasma exchange after a third kidney transplant for atypical hemolytic uremic syndrome associated with a CFH mutation.

    Science.gov (United States)

    Davin, Jean-Claude; Gracchi, Valentina; Bouts, Antonia; Groothoff, Jaap; Strain, Lisa; Goodship, Tim

    2010-04-01

    Kidney transplant in patients with atypical hemolytic uremic syndrome (aHUS) is associated with a poor outcome because of recurrent disease, especially in patients known to have a factor H mutation. Long-term prophylactic plasma exchange and combined liver-kidney transplant have prevented graft loss caused by recurrence. However, the mortality associated with liver transplant is not negligible, and prophylactic plasma exchange requires permanent vascular access and regular hospitalization and exposes the patient to potential allergic reactions to plasma. Eculizumab is a high-affinity humanized monoclonal antibody that binds to C5 and thus prevents generation of C5a and the membrane attack complex. We report the case of a 17-year-old girl with aHUS associated with a mutation in the gene for complement factor H (CFH; c.3572C>T, Ser1191Leu) who was highly dependent on plasma exchange. Because of severe allergic reactions to plasma after the third renal graft, eculizumab was introduced in place of plasma exchange without problems. This and other reports suggest that the promise of complement inhibitors in the management of aHUS is going to be fulfilled.

  7. Therapeutic plasma exchange in pediatric patients of Guillain-Barre syndrome: Experience from a Tertiary Care Centre

    Directory of Open Access Journals (Sweden)

    Maitrey Gajjar

    2016-01-01

    Full Text Available Background and Objective: Therapeutic Plasma Exchange (TPE is performed effectively and safely in adult patients, but the use of TPE is limited in paediatric patients due to lack of universally accepted indications and technical challenges like establishment of adequate vascular access, low blood volume, increased incidence of adverse events during procedure and poor co-operation of patients during procedure. We present our experience of TPE in paediatric patients to assess the effectiveness and safety of TPE in paediatric patients. Materials and Methods: A total 122 TPE procedures were performed in 40 paediatric patients between 3 to 15 years of age group with Guillain Barre Syndrome (GBS. TPE procedures were performed on alternate days depending on the clinical condition of the patient. Patient′s total blood volume was calculated as per Nadler′s formula and processed through central double lumen catheter. 1-1.5 plasma volume was exchanged with normal saline and fresh frozen plasma. Results: A total of 122 TPE procedures (with an average of three procedures per patient were performed on 40 paediatric patients. More than three TPE procedures were performed in 29 patients, of which 27 patients showed improvement from grade-0 and grade-I to grade-III. One did not show any response and succumbed to the disease. Complications were observed in 14 patients which were well managed. Inadequate vascular access was most common complication observed in 11 patients. Conclusion: TPE in paediatric patients has been increasing and has been shown to be effective as first line or adjunctive therapy in selected diseases. It is safe procedure when volume shifts, calcium supplementation and venous access are taken care.

  8. Silenced uses and moral ideals in the exchange of Danish blood and plasma

    DEFF Research Database (Denmark)

    Sheikh, Zainab Afshan; Deleuran, Ida; Hoeyer, Klaus

    2016-01-01

    as ‘beyond trade’. This stands in remarkable contrast to the fact that the donated plasma is sold to an international pharmaceutical company in consequence of rules of tender set by the European Union. Donors are not aware of this, and when asked in hypothetical terms about trade, they strongly oppose it...

  9. Flow-Induced New Channels of Energy Exchange in Multi-Scale Plasma Dynamics – Revisiting Perturbative Hybrid Kinetic-MHD Theory

    Science.gov (United States)

    Shiraishi, Junya; Miyato, Naoaki; Matsunaga, Go

    2016-01-01

    It is found that new channels of energy exchange between macro- and microscopic dynamics exist in plasmas. They are induced by macroscopic plasma flow. This finding is based on the kinetic-magnetohydrodynamic (MHD) theory, which analyses interaction between macroscopic (MHD-scale) motion and microscopic (particle-scale) dynamics. The kinetic-MHD theory is extended to include effects of macroscopic plasma flow self-consistently. The extension is realised by generalising an energy exchange term due to wave-particle resonance, denoted by δ WK. The first extension is generalisation of the particle’s Lagrangian, and the second one stems from modification to the particle distribution function due to flow. These extensions lead to a generalised expression of δ WK, which affects the MHD stability of plasmas. PMID:27160346

  10. Plasma renin, plasma aldosterone and exchangeable sodium in normotensive and hypertensive kidney transplant recipients with and without transplant renal artery stenosis.

    Science.gov (United States)

    Kornerup, H J; Pedersen, E B

    1977-01-01

    Blood pressure (BP), plasma renin concentration (PRC), plasma aldosterone concentration (PAC) and exchangeable sodium (ES) were studied in 19 kidney recipients on different fixed levels of sodium intake after successful kidney transplantation. The following groups of kidney recipients were investigated: group 1: 7 normotensives, group 2:7 hypertensives without transplant renal artery stenosis (TRAS), group 3:5 hypertensives with angiographically verified TRAS. Hypertension in the recipients without TRAS (group 2) was characterized by a positive correlation between BP and ES and a normal response of PRC and PAC to a fixed low (10 mEQ/day) and high (150 mEq/day) sodium intake. In contrast, hypertension in the recipients with TRAS (group 3) was characterized by a normal or varyingly increased PRC on a liberal sodium intake and a reduced response of PRC to sodium restriction, whereas PAC did not differ from the other groups of recipients. In one recipient in group 3 who underwent surgical correction for TRAS, PRC and PAC decreased before operation during sodium restriction, but BP remained high until after operation, when it normalized simultaneously with a decrease in ES. The results indicate that sodium retention is involved in the pathogenesis of posttransplant hypertension and suggest that an increased activity of the renin--angiotensin system is counterbalanced by an accumulation of sodium in TRAS.

  11. Refractory heparin induced thrombocytopenia with thrombosis (HITT) treated with therapeutic plasma exchange and rituximab as adjuvant therapy.

    Science.gov (United States)

    Schell, Amy M; Petras, Melissa; Szczepiorkowski, Zbigniew M; Ornstein, Deborah L

    2013-10-01

    We report a case of refractory heparin-induced thrombocytopenia with thrombosis (HITT) with prolonged thrombocytopenia and multiple thrombotic complications that failed to improve despite aggressive treatment. A 60 year old female with a prior history of venous thromboembolism was admitted with an acute pulmonary embolism, and developed HITT after several days on heparin therapy. She suffered multiple complications including bilateral venous limb gangrene, acute renal failure, and refractory thrombocytopenia, leading us to use multimodality therapy including therapeutic plasma exchange (TPE) and rituximab immunosuppression. The patient had transient improvements in her thrombocytopenia with TPE, and rituximab was added in an attempt to reduce antibody production. She eventually required bilateral limb amputation, and only after removal of the gangrenous limbs did her platelet count show sustained improvement. We discuss the possible contribution of infection to her prolonged course.

  12. Role of Therapeutic Plasma Exchange in Treatment of Tumefactive Multiple Sclerosis-Associated Low CD4 and CD8 Levels

    Directory of Open Access Journals (Sweden)

    Kristen Lew

    2016-08-01

    Full Text Available We report a 35-year-old healthy male who developed central nervous system inflammatory demyelinating disease consistent with tumefactive multiple sclerosis. About 2 weeks after onset of symptoms and prior to initiation of therapy, the patient had lymphopenia and low CD4 and CD8 levels. His lymphocyte count was 400 cells/µl (850–3,900 cells/µl, CD4 was 193 cells/µl (490–1,740 cells/µl and CD8 was 103 cells/µl (180–1,170 cells/µl. He was treated with intravenous methylprednisolone followed by therapeutic plasma exchange, the levels of CD4 and CD8 normalized, and ultimately, he recovered completely.

  13. Impurity line emission due to thermal charge exchange in JET edge plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Maggi, C.F.; Horton, L.D.; Koenig, R.; Stamp, M. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Summers, H.P. [Strathclyde Univ., Glasgow (United Kingdom)

    1994-07-01

    High n-shell emission from hydrogen-like carbon (C VI, n=8-7) has been routinely observed from the plasma edge of JET. By comparing the measured spectral line intensities with the signals predicted by advanced atomic physics modelling of carbon and hydrogen radiation, integrated with modelling of the divertor and edge plasma, it is concluded that charge transfer from excited state hydrogen donors into fully stripped carbon ions can account for the observed spectral emission, but that the hydrogen distribution and to a lesser extent the carbon distribution away from the strike zone predicted by the transport model are too low. Data presented are those of three upper X-point discharges, where the target material was carbon. 5 refs., 1 fig., 3 tabs.

  14. Na(+)/Ca (2+) exchange and the plasma membrane Ca(2+)-ATPase in β-cell function and diabetes.

    Science.gov (United States)

    Herchuelz, André; Nguidjoe, Evrard; Jiang, Lin; Pachera, Nathalie

    2013-01-01

    The rat pancreatic β-cell expresses two splice variants of the Na+/Ca(2+) exchanger 1 (NCX1) and six splice variants of the plasma membrane Ca(2+)-ATPase (PMCA). In the β-cell, Na(+)/Ca(2+) exchange displays a high capacity, contributes to both Ca(2+) outflow and influx and participates to the control of insulin release. Gain of function studies show that overexpression of NCX1 or PMCA2 leads to endoplasmic reticulum (ER) Ca(2+) depletion with subsequent ER stress, decrease in β-cell proliferation and β-cell death by apoptosis. Interestingly, chronic exposure to cytokines or high free fatty acids concentration also induces ER Ca(2+) depletion and β-cell death in diabetes. Loss of function studies shows, on the contrary, that heterozygous inactivation of NCX1 (Ncx1 ( +/- )) leads to an increase in β-cell function (insulin production and release) and a fivefold increase in both β-cell mass and proliferation. The mutation also increases β-cell resistance to hypoxia, and Ncx1 ( +/- ) islets show a four to seven times higher rate of diabetes cure than Ncx1 ( +/+ ) islets when transplanted in diabetic animals. Thus, downregulation of the Na(+)/Ca(2+) exchanger leads to various changes in β-cell function that are opposite to the major abnormalities seen in diabetes. In addition, the β-cell, which is an excitable cell, includes the mutually exclusive exon B in the alternative splicing region of NCX1, which confers a high sensitivity of its NCX splice variants (NCX1.3 & 1.7) to the inhibitory action of compounds like KB-R7943. This provides a unique model for the prevention and treatment of β-cell dysfunction in diabetes and following islet transplantation.

  15. Automated suspension of washed erythrocytes in fresh-frozen plasma for exchange transfusion. Obtaining a desired hematocrit.

    Science.gov (United States)

    Wenk, R E; Masucol, E; Brewer, M K

    1981-01-01

    Stored red blood cells may be automatically saline washed and resuspended in fresh-frozen plasma to yield a final product with any hematocrit that is desired. The technique provides for rapid processing and issue of blood and minimal risk of contamination of the unit. Red blood cells are more readily available than whole blood, and their use, with fresh-frozen plasma, in exchange transfusion, provides similar advantages, including low potassium content and normal content of procoagulants and bilirubin binding capacity. The method of reconstruction is based on calculations that use empirically determined estimates of average hematocrit and specific gravity of red blood cells and the volumetric flow characteristics of a programmable IBM 2991 Blood Processor. Only the weight of the stored red blood cell unit is required as a measurement at the time of preparing the resuspended cells. Quality-control studies of the final hematocrit indicates a 2.4 per cent standard deviation from a target value of 55 per cent.

  16. Management of an acute outbreak of diarrhoea-associated haemolytic uraemic syndrome with early plasma exchange in adults from southern Denmark: an observational study

    DEFF Research Database (Denmark)

    Colic, Edin; Dieperink, Hans; Titlestad, Kjell

    2011-01-01

    Diarrhoea-associated haemolytic uraemic syndrome in adults is a life-threatening, but rare multisystem disorder that is characterised by acute haemolytic anaemia, thrombocytopenia, and renal insufficiency. We aimed to assess the success of management of this disorder with plasma exchange therapy....

  17. Compact, accurate description of diagnostic neutral beam propagation and attenuation in a high temperature plasma for charge exchange recombination spectroscopy analysis.

    Science.gov (United States)

    Bespamyatnov, Igor O; Rowan, William L; Granetz, Robert S

    2008-10-01

    Charge exchange recombination spectroscopy on Alcator C-Mod relies on the use of the diagnostic neutral beam injector as a source of neutral particles which penetrate deep into the plasma. It employs the emission resulting from the interaction of the beam atoms with fully ionized impurity ions. To interpret the emission from a given point in the plasma as the density of emitting impurity ions, the density of beam atoms must be known. Here, an analysis of beam propagation is described which yields the beam density profile throughout the beam trajectory from the neutral beam injector to the core of the plasma. The analysis includes the effects of beam formation, attenuation in the neutral gas surrounding the plasma, and attenuation in the plasma. In the course of this work, a numerical simulation and an analytical approximation for beam divergence are developed. The description is made sufficiently compact to yield accurate results in a time consistent with between-shot analysis.

  18. On-line clean-up and screening of oxacillin and cloxacillin in human urine and plasma with a weak ion exchange monolithic column.

    Science.gov (United States)

    Yang, Gengliang; Feng, Sha; Liu, Haiyan; Yin, Junfa; Zhang, Li; Cai, Liping

    2007-07-01

    A weak ion exchange monolithic column prepared by modifying the GMA-MAA-EDMA (glycidyl methacrylate-methacrylic acid-ethylene glycol dimethacrylate) monoliths with ethylenediamine was applied to remove matrix compounds in biological fluid. Using this monolithic column, on-line clean-up and screening of oxacillin and cloxacillin in human urine and plasma samples had been investigated. Chromatography was performed by reversed-phase HPLC on a C(18) column with ultraviolet detection at 225 nm. Results showed that the ion exchange monolithic column could be used for deproteinization and retaining oxacillin and cloxacillin in human urine and plasma, which provided a simple and fast method for assaying drugs in human urine and plasma.

  19. Separation of gold, palladium and platinum in chromite by anion exchange chromatography for inductively coupled plasma atomic emission spectrometric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Kwang Soon; Lee, Chang Heon; Park, Yeong Jae; Joe, Kih Soo; Kim, Won Ho [KAERI, Taejon (Korea, Republic of)

    2001-08-01

    A study has been carried out on the separation of gold, iridium, palladium, rhodium, ruthenium and platinum in chromite samples and their quantitative determination using inductively coupled plasma atomic emission spectrometry (ICP-AES). The dissolution condition of the minerals by fusion with sodium peroxide was optimized and chromatographic elution behavior of the rare metals was investigated by anion exchange chromatography. Spectral interference of chromium, a matrix of the minerals, was investigated on determination of gold. Chromium interfered on determination of gold at the concentration of 500 mg/L and higher. Gold plus trace amounts of iridium, palladium, rhodium and ruthenium, which must be preconcentrated before ICP-AES was separated by anion exchange chromatography after reducing Cr(VI) to Cr(III) by H{sub 2}O{sub 2}. AuCl{sup -}{sub 4} retained on the resin column was selectively eluted with acetone- HNO{sub 3}-H{sub 2}O as an eluent. In addition, iridium, palladium, rhodium and ruthenium remaining on the resin column were eluted as a group with concentrated HCl. However, platinum was eluted with concentrated HNO{sub 3}. The recovery yield of gold with acetone-HNO{sub 3}-H{sub 2}O was 100.7 {+-} 2.0 % , and the yields of palladium and platinum with concentrated HCl and HNO{sub 3} were 96.1 {+-} 1.8% and 96.6 {+-} 1.3%, respectively. The contents of gold and platinum in a Mongolian chromite sample were 32.6 {+-} 2.2 {mu}g/g and 1.6 {+-} 0.14 {mu}g/g, respectively. Palladium was not detected.

  20. Alumina-carbon nanofibers nanocomposites obtained by spark plasma sintering for proton exchange membrane fuel cell bipolar plates

    Energy Technology Data Exchange (ETDEWEB)

    Borrell, A.; Torrecillas, R. [Centro de Investigacion en Nanomateriales y Nanotecnologia (CINN) Consejo Superior de Investigaciones Cientificas, Universidad de Oviedo, Principado de Asturias, Parque Tecnologico de Asturias, Llanera Asturias (Spain); Rocha, V.G.; Fernandez, A. [ITMA Materials Technology, Parque Tecnologico de Asturias, Llanera Asturias (Spain)

    2012-08-15

    There is an increasing demand of multifunctional materials for a wide variety of technological developments. Bipolar plates for proton exchange membrane fuel cells are an example of complex functionality components that must show among other properties high mechanical strength, electrical, and thermal conductivity. The present research explored the possibility of using alumina-carbon nanofibers (CNFs) nanocomposites for this purpose. In this study, it was studied for the first time the whole range of powder compositions in this system. Homogeneous powders mixtures were prepared and subsequently sintered by spark plasma sintering. The materials obtained were thoroughly characterized and compared in terms of properties required to be used as bipolar plates. The control on material microstructure and composition allows designing materials where mechanical or electrical performances are enhanced. A 50/50 vol.% alumina-CNFs composite appears to be a very promising material for this kind of application. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. The dose of nafamostat mesilate during plasma exchange with continuous hemodiafiltration in the series-parallel circuit.

    Science.gov (United States)

    Nakae, Hajime; Igarashi, Toshiko; Tajimi, Kimitaka

    2006-06-01

    We studied nafamostat mesilate (NM) and interleukin (IL)-18 levels to determine whether the dose of NM is reduced during plasma exchange (PE) with continuous hemodiafiltration (CHDF) when the series-parallel circuit is used. The subjects of the current study included four patients with acute hepatic failure who underwent PE with CHDF. The four patients underwent a total 15 PE + CHDF procedures, and for each procedure, they were randomized to receive either a half-dose of NM or no NM in the CHDF circuit. Eight procedures were carried out with NM administration, and seven were carried out without NM administration. The dose of NM in the NM group was significantly higher than that in the non-NM group (P = 0.040). No significant differences were observed between the two groups in the inlet NM concentration, the outlet NM concentration, or the rate of IL-18 removal. No statistical correlation was observed between the IL-18 level and the NM dose, the inlet NM concentration, or the outlet NM concentration. There was no blood access difficulty such as catheter failure or clotting of the filter. Thus, it might be possible to carry out PE and CHDF with the series-parallel method without administration of NM in the CHDF circuit.

  2. Evaluation of the therapeutic efficacy of lamivudine combined with plasma exchange for treating acute-on-chronic hepatitis B liver failure

    Directory of Open Access Journals (Sweden)

    HU Qijiang

    2013-02-01

    Full Text Available ObjectiveTo observe the clinical effects of lamivudine antiviral therapy combined with plasma exchange in patients with acute-on-chronic hepatitis B liver failure. MethodsForty-seven patients (treatment group were administered lamivudine and underwent plasma exchange. An additional forty-five patients (control group were administered lamivudine but no plasma exchange. Otherwise, all patients received the same basic medical treatment. The two groups were further divided into three sub-groups according to the model for end-stage liver disease (MELD score: <30, 30-39, and ≥40. The significance of differences in survival rates between the groups and sub-groups was determined by the χ2 test. ResultsThe overall survival rate was significantly better in the treatment group (63.82% vs. control group: 44.44%; χ2=4.31, P<0.05. Within the treatment group, the survival rates were highest in the 30-39 MELD score sub-group (71.42%, which was significantly different from survival rate in the same sub-group of the controls (vs. 38.10%; χ2=4.71, P<005. The other two MELD score sub-groups showed no significant differences between the treatment and control groups (all P>0.05. ConclusionCombined therapy consisting of lamivudine treatment and plasma exchange can improve the survival rate of patients with acute-on-chronic hepatitis B liver failure who have MELD scores between 30 and 39.

  3. Therapeutic plasma exchange as a steroid-sparing therapy in a patient with limbic encephalitis due to antibodies to voltage-gated potassium channels.

    Science.gov (United States)

    Martin, Isabella W; Martin, Christi-Lynn B; Dunbar, Nancy M; Lee, Stephen L; Szczepiorkowski, Zbigniew M

    2016-02-01

    Autoantibodies to the voltage-gated potassium channel (VGKC) complex cause a spectrum of non-paraneoplastic neurologic syndromes including limbic encephalitis (LE). We report a case of a man with LE who underwent a course of therapeutic plasma exchange (TPE) in addition to other immunomodulatory therapies and experienced sustained clinical resolution of his symptoms. This report adds to the existing literature supporting TPE in cases of LE due to VGKC complex autoantibodies.

  4. Effectiveness of combining plasma exchange with continuous hemodiafiltration on acute Fatty liver of pregnancy complicated by multiple organ dysfunction.

    Science.gov (United States)

    Chu, Yu-Feng; Meng, Mei; Zeng, Juan; Zhou, Hai-Yan; Jiang, Jin-Jiao; Ren, Hong-Sheng; Zhang, Ji-Cheng; Zhu, Wen-Ying; Wang, Chun-Ting

    2012-06-01

    Acute fatty liver of pregnancy (AFLP) is a rare disease of progressive hepatic insufficiency and secondary systemic complications that induce significant maternal risk. The application of combining plasma exchange (PE) and continuous hemodiafiltration (CHDF) is a novel concept for patients with AFLP. Since 2002, we have utilized the combination of PE with CHDF as adjunctive medical therapy for 11 AFLP patients with multiple organ dysfunction. Before PE and CHDF initiation, four patients had signs and symptoms of encephalopathy, four required ventilatory support, and all 11 were developing liver failure, significant renal compromise, and coagulopathy. PE combined with CHDF for patients was initiated a mean of 2 days postpartum (range, days 0-3). Daily or every other day PE combined with CHDF was undertaken on two to eight occasions for each of the 11 patients. Ten patients responded with composite clinical and laboratory improvement and were discharged to the ward, then cured and discharged from hospital; one patient died of septic shock. Average duration of hospitalization was 17 days (range, days 9-38) from time of admission to discharge; the average duration of intensive care unit was 10 days (range, days 4-23). No significant PE- and CHDF-related complications occurred. These results indicate that combing PE and CHDF in a series-parallel circuit is an effective and safe treatment for patients with severe AFLP. This finding may have important implications for the development of an effective treatment for patients with AFLP suffering multiple organ dysfunction. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  5. Does early initiation of therapeutic plasma exchange improve outcome in pediatric stem cell transplant-associated thrombotic microangiopathy?

    Science.gov (United States)

    Jodele, Sonata; Laskin, Benjamin L; Goebel, Jens; Khoury, Jane C; Pinkard, Susan L; Carey, Patricia M; Davies, Stella M

    2013-03-01

    The use of therapeutic plasma exchange (TPE) in hematopoietic stem cell transplant-associated thrombotic microangiopathy (TA-TMA) is controversial because the exact mechanism of injury in TA-TMA is not yet understood. The study objective was to retrospectively review the outcome of children receiving TPE for TA-TMA at our institution. We hypothesized that patients initiating TPE earlier in their disease course would receive a greater benefit than those starting later, regardless of the therapeutic mechanism. We identified 10 consecutive pediatric patients with TA-TMA treated with TPE. Nine of these patients showed normalization of the laboratory variables associated with microangiopathy during their TPE course, but only five patients recovered renal function and survived TA-TMA. The five survivors started TPE a median of 17 days (range, 4-25 days) after TA-TMA diagnosis while the five patients who died started TPE a median of 32 days (range, 17-73 days) after TA-TMA was diagnosed. Three of the five survivors had multiorgan failure at TA-TMA diagnosis and completely recovered with early institution of TPE. These three survivors were able to discontinue renal replacement therapy, and all achieved a normal posttreatment creatinine. The five patients with later institution of TPE progressed to end-stage renal disease and all died. There were no serious TPE-related complications in either group. This is the first report evaluating TPE response in regard to procedure initiation time after TA-TMA diagnosis. Our data suggests that early initiation of TPE might be beneficial even in patients with multiorgan failure due to TA-TMA. © 2012 American Association of Blood Banks.

  6. Effects of weakly coupled and dense quantum plasmas environments on charge exchange and ionization processes in Na+ + Rb(5s) atom collisions

    Science.gov (United States)

    Pandey, Mukesh Kumar; Lin, Yen-Chang; Ho, Yew Kam

    2017-02-01

    The effects of weakly coupled or classical and dense quantum plasmas environment on charge exchange and ionization processes in Na+ + Rb(5s) atom collision at keV energy range have been investigated using classical trajectory Monte Carlo (CTMC) method. The interaction of three charged particles are described by the Debye-Hückel screen potential for weakly coupled plasma, whereas exponential cosine-screened Coulomb potential have been used for dense quantum plasma environment and the effects of both conditions on the cross sections are compared. It is found that screening effects on cross sections in high Debye length condition is quite small in both plasma environments. However, enhanced screening effects on cross sections are observed in dense quantum plasmas for low Debye length condition, which becomes more effective while decreasing the Debye length. Also, we have found that our calculated results for plasma-free case are comparable with the available theoretical results. These results are analyzed in light of available theoretical data with the choice of model potentials.

  7. Treatment Efficacy and Safety During Plasma Exchange With Citrate Anticoagulation: A Randomized Study of 4 Versus 15% Citrate.

    Science.gov (United States)

    Antonic, Manja; Gubensek, Jakob; Buturovic-Ponikvar, Jadranka; Ponikvar, Rafael

    2016-04-01

    In plasma exchange (PE), contrary to dialysis, there is no ultrafiltration, and the volume of anticoagulant contributes to volume overload of the patient and might also reduce PE efficiency through dilution. To reduce the volume of citrate, we compared 4 and 15% citrate anticoagulation protocols in PE in a randomized study, aiming to evaluate PE efficacy, anticoagulation efficiency, and overall safety. In addition to standard biochemical analyses during PE treatments, the elimination rate (ER) of immunoglobulins was calculated to evaluate PE efficacy. Anticoagulation was evaluated by postfilter ionized calcium, visual evaluation of the extracorporeal system, and change in the sieving coefficient (SC) during PE. Accumulation of citrate was determined by calculating the total-to-ionized calcium ratio and measuring the citrate concentration after PE. One hundred forty procedures (70 in each group) were performed in 37 patients. The mean citrate infusion rate was 197 ± 10 mL/h in the 4% and 59 ± 5.5 mL/h in the 15% groups, respectively; the total volume of infused citrate was 502 ± 77 mL versus 164 ± 52 mL (P comparable. Ionized calcium was stable during the procedures, and there were no significant side effects. Although postfilter ionized calcium was on the upper limit of the target range (0.41 ± 0.16 vs. 0.37 ± 0.14 mmol/L, P = 0.38), the visual assessment score was excellent, and even a rise in SC was observed during the procedures in both groups. The total-to-ionized calcium ratio was increased in 20 versus 22% of procedures, and citrate concentrations after PE were also similar (1306 ± 441 vs. 1263 ± 405 μmol/L). To conclude, we were unable to show superior PE efficacy in the 15% citrate group, but we significantly reduced the infused volume, which is important in patients with fluid overload. Both citrate protocols were found to provide excellent anticoagulation without significant metabolic disturbances

  8. Life-threatening postpartum hemolysis, elevated liver functions tests, low platelets syndrome versus thrombocytopenic purpura - Therapeutic plasma exchange is the answer

    Directory of Open Access Journals (Sweden)

    Prashant Nasa

    2011-01-01

    Full Text Available The differential diagnosis of life-threatening microangiopathic disorders in a postpartum female includes severe preeclampsia-eclampsia, hemolysis, elevated liver functions tests, low platelets syndrome and thrombotic thrombocytopenic purpura. There is considerable overlapping in the clinical and laboratory findings between these conditions, and hence an exact diagnosis may not be always possible. However, there is considerable maternal mortality and morbidity associated with these disorders. This case underlines the complexity of pregnancy-related microangiopathies regarding their differential diagnosis, multiple organ dysfunction and role of therapeutic plasma exchange in their management.

  9. Acute severe organophosphate poisoning in a child who was successfully treated with therapeutic plasma exchange, high-volume hemodiafiltration, and lipid infusion.

    Science.gov (United States)

    Yesilbas, Osman; Kihtir, Hasan S; Altiti, Mohammad; Petmezci, Mey Talip; Balkaya, Seda; Bursal Duramaz, Burcu; Ersoy, Melike; Sevketoglu, Esra

    2016-10-01

    Acute severe organophosphate poisoning is a serious complication seen in developing and agricultural countries. Pralidoxime and high dose atropine are the standard treatments. There is no consensus about acute severe organophosphate poisonings that are unresponsive to pralidoxime, atropine, and supportive therapies. We report a case of acute severe organophosphate poisoning that was unresponsive to standard treatments and successfully treated with high-volume continuous venovenous hemodiafiltration and therapeutic plasma exchange combined with lipid infusion. J. Clin. Apheresis 31:467-469, 2016. © 2015 Wiley Periodicals, Inc.

  10. Selective and Accurate Determination Method of Propofol in Human Plasma by Mixed-Mode Cation Exchange Cartridge and GC-MS

    Directory of Open Access Journals (Sweden)

    Jae Sung Pyo

    2016-01-01

    Full Text Available A gas chromatography-mass spectrometry (GC-MS method for the determination of propofol in human plasma has been developed and validated. Propofol was extracted from human plasma by using mixed-mode cation exchange/reversed-phase (MCX cartridges. As propofol easily volatilizes during concentration, 100% methanol was injected directly into GC-MS to elute propofol. Despite avoiding concentration process of the eluted solution, lower limit of quantization (LLOQ of propofol was 25 ng/mL. The validated method exhibited good linearity (R2=0.9989 with accuracy and precision −5.8%~11.7% and 3.7%~11.6%, respectively. The other validation parameters, recovery and matrix effect, ranged from 96.6% to 99.4% and 95.3% to 101.4%, respectively. Propofol standard was quantified to evaluate possible loss due to the concentration processes, nitrogen gas and centrifugal vacuum. These two concentration processes resulted in notable decrease in the quantity of propofol, signifying avoiding any concentration processes during propofol quantification. Also, to confirm suitability of the developed method, authentic human plasma samples were analyzed. The selective assay method using MCX cartridge and GC-MS facilitated quantification of propofol in plasma sample accurately by preventing any losses due to the concentration processes.

  11. Selective and Accurate Determination Method of Propofol in Human Plasma by Mixed-Mode Cation Exchange Cartridge and GC-MS.

    Science.gov (United States)

    Pyo, Jae Sung

    2016-01-01

    A gas chromatography-mass spectrometry (GC-MS) method for the determination of propofol in human plasma has been developed and validated. Propofol was extracted from human plasma by using mixed-mode cation exchange/reversed-phase (MCX) cartridges. As propofol easily volatilizes during concentration, 100% methanol was injected directly into GC-MS to elute propofol. Despite avoiding concentration process of the eluted solution, lower limit of quantization (LLOQ) of propofol was 25 ng/mL. The validated method exhibited good linearity (R (2) = 0.9989) with accuracy and precision -5.8%~11.7% and 3.7%~11.6%, respectively. The other validation parameters, recovery and matrix effect, ranged from 96.6% to 99.4% and 95.3% to 101.4%, respectively. Propofol standard was quantified to evaluate possible loss due to the concentration processes, nitrogen gas and centrifugal vacuum. These two concentration processes resulted in notable decrease in the quantity of propofol, signifying avoiding any concentration processes during propofol quantification. Also, to confirm suitability of the developed method, authentic human plasma samples were analyzed. The selective assay method using MCX cartridge and GC-MS facilitated quantification of propofol in plasma sample accurately by preventing any losses due to the concentration processes.

  12. Refractory autoimmune hemolytic anemia in a patient with DiGeorge syndrome treated successfully with plasma exchange: a case report and review of the literature.

    Science.gov (United States)

    Damlaj, Moussab; Séguin, Chantal

    2014-11-01

    Warm antibody autoimmune hemolytic anemia (AIHA) results from targeted antibodies towards the red blood cells (RBCs) and can be either idiopathic or secondary to certain diseases, such as autoimmune disorders or malignancy, drugs, or infection. Patients with DiGeorge syndrome are particularly vulnerable to autoimmune conditions secondary to thymic hypoplasia and dysfunction of the immune system. First-line therapy for AIHA consists of corticosteroids, with most patients showing signs of response. Relapses are not uncommon and are treated with splenectomy or rituximab. There is a paucity of reports in the literature regarding treatment options beyond this stage. Herein, we describe an unusual case of a 20-year-old female affected by DiGeorge syndrome with a history of immune thrombocytopenia (ITP), who presented with life-threatening AIHA. Standard first- and second-line therapeutic modalities were ineffective in controlling her disease and she ultimately underwent plasma exchange therapy with successful resolution of hemolysis. At her last follow-up, one year after her initial presentation, she remains clinically well without signs of hemolysis. We conclude that in refractory cases of warm AIHA, plasma exchange therapy can be a valuable tool in the therapeutic armamentarium.

  13. A single-center prospective study on the safety of plasma exchange procedures using a double-viral-inactivated and prion-reduced solvent/detergent fresh-frozen plasma as the replacement fluid in the treatment of thrombotic microangiopathy.

    Science.gov (United States)

    Vendramin, Chiara; McGuckin, Siobhan; Alwan, Ferras; Westwood, John-Paul; Thomas, Mari; Scully, Marie

    2017-01-01

    Patients presenting with acute episodes of thrombotic microangiopathies (TMAs) require urgent access to plasma exchange (PEX). OctaplasLG, a solvent/detergent fresh-frozen plasma product that has undergone viral inactivation and prion reduction step, has been used in our institution since 2013, replacing Octaplas. We prospectively reviewed 981 PEX procedures where OctaplasLG was the replacement fluid in 90 patients admitted acutely with a TMA presentation within our institution from January 1, 2013, to December 31, 2015. We recorded citrate toxicities, plasma reactions, viral transfer, complications related to central venous catheter, and venous thrombotic events (VTEs). Citrate toxicities were 5.4%, plasma reactions were 2%, and all were classified as Grade 1 or 2. VTE had an incidence of 12.2%, although 50% of the episodes occurred in early remission when patients were not receiving PEX. No line insertions complications were recorded. Line-associated infections were 2.2%. Hepatitis B and C serology and human immunodeficiency virus (HIV) were checked on admission. There were four patients who may have had passive transient transfer of hepatitis B antibodies from pooled plasma. No hepatitis C or HIV viral transfer was documented after treatment and no seroconversion was detected after treatment. Our data have demonstrated that the incidence of complications during PEX is low and using OctaplasLG is comparable to the low incidence of reactions. No cases of anaphylaxis, transfusion-related acute lung injury, or fatal plasma reactions were seen. There was no evidence of viral transmission or seroconversion after treatment. © 2016 AABB.

  14. [Three shades of fluids: Bergström 2.0 / Furosemide stress test / replacement fluid for therapeutic plasma exchange].

    Science.gov (United States)

    Schmidt, Julius J; Kielstein, Jan T

    2015-06-01

    Fluids play an important role in clinical nephrology.1) Temperature of dialysate fluid has recently re-attracted a lot of attention. Individualized cooling of the dialysate (0.5 °C below predialysis ear temperature) has been shown to not only prevent intradialytic hypotension but also to improve myocardial contractility and to prevent white matter changes in CKD5D.2) Access fluid in AKI is associated with an increased mortality. While Furosemide has no place in treating AKI the Furosemide stress test can help to identify patients with AKI that will eventually need renal replacement therapy.3) Components of replacement fluid for therapeutic plasma exchange (albumin or fresh frozen plasma) are high in demand. Especially the cost for albumin increases year by year. Alternative solutions such as immunoadsorption should be studied and employed for those indications where replenishment of plasma components is not necessary. Further, a seperate reimbursement of repalcement fluid seems necessary to avoid a decline in treatment quality.

  15. A fast acquisition rate system for charge exchange measurements at the plasma edge at the ASDEX Upgrade tokamak

    CERN Document Server

    Cavedon, Marco; Viezzer, Eleonora; Dux, Ralph; Geiger, Benedikt; McDermott, Rachael Marie; Meyer, Hendrik; Stroth, Ulrich

    2016-01-01

    In this work, a new type of high through-put Czerny-Turner spectrometer has been developed which allows to acquire multiple channels simultaneously with a repetition time on the order of \\SI{10}{\\us} at different wavelengths. The spectrometer has been coupled to the edge charge exchange recombination system at ASDEX Upgrade which has been recently refurbished with new lines of sight. Construction features, calibration methods, and initial measurements obtained with the new setup will be presented.

  16. Comparison of plasma exchange performances between Spectra Optia and COBE Spectra apheresis systems in repeated procedures considering variability and using specific statistical models.

    Science.gov (United States)

    Hequet, O; Stocco, V; Assari, S; Drillat, P; Le, Q H; Kassir, A; Rigal, D; Bouzgarrou, R

    2014-08-01

    Repeated therapeutic plasma exchange (TPE) procedures using centrifugation techniques became a standard therapy in some diseases. As the new device Spectra Optia (SPO; Terumo BCT) was available, we studied its performances in repeated procedures in 20 patients in three apheresis units. First we analysed the performance results obtained by SPO. Second we compared the performances of the SPO device to a standard device, COBE Spectra (CSP; Terumo BCT) in the same patients using statistical method of mixed effects linear regression that considers variability between patients, centres and apheresis procedures. The performances analysed were classified according to plasma removal performances and their consequences on patients whose blood disturbances were assessed. Primary outcome was plasma removal efficiency (PRE) and PRE-anticoagulant corrected which was a more accurate parameter. Secondary outcomes corresponded to the volume of ACD-A consumed, platelets content in waste bag, procedure duration and status of coagulation system observed after TPE sessions. Before comparing the performances of both devices we compared the plasma volumes (PVs) processed in both techniques which showed that the PVs processed in SPO procedures were lower than in CSP procedures. In these conditions the statistical analysis revealed similar performances in both apheresis devices in PRE (p = ns) but better performances with SPO when considering higher PRE corrected by anticoagulant volume used (p apheresis patients' coagulation blood levels were identical before SPO and CSP, we showed identical haemostasis disturbances after SPO and CSP but lower platelet losses and higher fibrinogen post-apheresis blood levels after SPO (p < 0.05). No side effects or technical complications occurred during and after SPO and CSP. This study demonstrated that the Spectra Optia device is an alternative device to today's standard, the COBE Spectra device.

  17. Successful Treatment of Focal Segmental Glomerulosclerosis after Kidney Transplantation with Plasma Exchange and Abatacept in a Patient with Juvenile Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Hannelore Sprenger-Mähr

    2016-01-01

    Full Text Available Recurrent focal segmental glomerulosclerosis (FSGS after renal transplantation is difficult to treat. Recently a series of four patients unresponsive to plasma exchange (PE and rituximab, who were successfully treated with abatacept, has been reported. We present a 26-year-old Caucasian patient who suffered from juvenile rheumatoid arthritis and developed severe proteinuria eleven days after transplantation. An allograft biopsy was suggestive of recurrent focal segmental glomerulosclerosis. He did not respond to PE therapy. A first dose of abatacept produced partial remission. Four weeks later proteinuria again increased and a second biopsy showed progression of disease. After another ineffective course of PE he was given a second dose of abatacept, which was followed by rapid, complete, and sustained resolution of proteinuria. This treatment caused a significant increase in BK and JC viremia. Whether abatacept ameliorated proteinuria via an effect on podocytes or on the patient’s primary disease remains speculative.

  18. Plasma exchanges for the treatment of severe systemic necrotizing vasculitides in clinical daily practice: Data from the French Vasculitis Study Group.

    Science.gov (United States)

    de Luna, Gonzalo; Chauveau, Dominique; Aniort, Julien; Carron, Pierre-Louis; Gobert, Pierre; Karras, Alexandre; Marchand-Adam, Sylvain; Maurier, François; Hatron, Pierre-Yves; Mania, Alexandre; le Guenno, Guillaume; Bally, Stéphane; Bienvenu, Boris; Cardineau, Eric; Goulenok, Tiphaine; Jourde-Chiche, Noémie; Samson, Maxime; Huart, Antoine; Pourrat, Jacques; Tiple, Aurélien; Aumaitre, Olivier; Puéchal, Xavier; Heshmati, Farhad; le Jeunne, Claire; Mouthon, Luc; Guillevin, Loïc; Terrier, Benjamin

    2015-12-01

    The use of plasma exchanges (PLEX) in systemic necrotizing vasculitides (SNV) still need to be codified. To describe indications, efficacy and safety of PLEX for the treatment of SNV, we conducted a multicenter retrospective study on patients with ANCA-associated vasculitis (AAV) or non-viral polyarteritis nodosa (PAN) treated with PLEX. One hundred and fifty-two patients were included: GPA (n = 87), MPA (n = 56), EGPA (n = 4) and PAN (n = 5). PLEX were used for rapidly progressive glomerulonephritis (RPGN) in 126 cases (86%), alveolar hemorrhage in 64 cases (42%), and severe mononeuritis multiplex in 23 cases (15%). In patients with RPGN, there was a significant improvement in renal function compared to baseline value (P studies are ongoing to define optimal indications, PLEX regimen and concomitant medications.

  19. Survey of inorganic arsenic in marine animals and marine certified reference materials by anion exchange high-performance liquid chromatography-inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Sloth, Jens Jørgen; Larsen, Erik Huusfeldt; Julshamn, Kåre

    2005-01-01

    A method for the determination of inorganic arsenic in seafood samples using high-performance liquid chromatography-inductively coupled plasma mass spectrometry is described. The principle of the method relied on microwave-assisted alkaline dissolution of the sample, which at the same time oxidized...... arsenite [As(Ill)] to arsenate [As(V)], whereby inorganic arsenic could be determined as the single species As(V). Anion exchange chromatography using isocratic elution with aqueous ammonium carbonate as the mobile phase was used for the separation of As(V) from other coextracted organoarsenic compounds......, including arsenobetaine. The stability of organoarsenic compounds during the sample pretreatment was investigated, and no degradation/conversion to inorganic arsenic was detected. The method was employed for the determination of inorganic arsenic in a variety of seafood samples including fish, crustaceans...

  20. High-volume plasma exchange in a patient with acute liver failure due to non-exertional heat stroke in a sauna.

    Science.gov (United States)

    Chen, Kuan-Jung; Chen, Tso-Hsiao; Sue, Yuh-Mou; Chen, Tzay-Jinn; Cheng, Chung-Yi

    2014-10-01

    Heat stroke is a life-threatening condition characterized by an increased core body temperature (over 40°C) and a systemic inflammatory response, which may lead to a syndrome of multiple organ dysfunction. Heat stroke may be due to either strenuous exercise or non-exercise-induced exposure to a high environmental temperature. Current management of heat stroke is mostly supportive, with an emphasis on cooling the core body temperature and preventing the development of multiple organ dysfunction. Prognosis of heat stroke depends on the severity of organ involvement. Here, we report a rare case of non-exercise-induced heat stroke in a 73-year-old male patient who was suffering from acute liver failure after prolonged exposure in a hot sauna room. We successfully managed this patient by administering high-volume plasma exchange, and the patient recovered completely after treatment.

  1. Analysis of BNP7787 thiol-disulfide exchange reactions in phosphate buffer and human plasma using microscale electrochemical high performance liquid chromatography.

    Science.gov (United States)

    Shanmugarajah, Dakshine; Ding, Daoyuan; Huang, Quili; Chen, Xinghai; Kochat, Harry; Petluru, Pavankumar N; Ayala, Philippe Y; Parker, Aulma R; Hausheer, Frederick H

    2009-04-01

    BNP7787 (disodium 2,2'-dithio-bis ethane sulfonate; Tavocept) is a novel water-soluble investigational agent that is undergoing clinical development for prevention and mitigation of cisplatin-induced nephrotoxicity. BNP7787 is a disulfide that undergoes thiol-disulfide exchange reactions in vivo with physiological thiols. Mesna-disulfide heteroconjugates that form as a result of these exchange reactions may play a key role in the protection against cisplatin-induced nephrotoxicity. Although several analytical methods have been used to detect thiols and disulfides, they have notable limitations including (i) low sensitivity, (ii) interference by chemical modification by derivatization reagents, and (iii) cumbersome sample preparation. In this paper, a sensitive micro-HPLC-EC method is described that identifies BNP7787 and mesna in plasma and phosphate buffer across a broad concentration range from 500nM to 100microM. This method utilizes a dual electrochemical detector equipped with a wall-jet gold electrode. The approach described here facilitates the identification of BNP7787 and mesna down to nanomolar levels. Although we did not focus on optimizing the approach for other thiol and disulfide compounds, we believe this approach could be optimized and used in the identification of other thiols and disulfides in plasma. The assay requires significantly less sample preparation and does not involve the use of derivatizing agents (i.e., the thiol and disulfide species can be detected directly) and represents an important advance over previous methods. This method was used to detect and quantitate BNP7787 and to monitor and kinetically characterize the interactions of BNP7787 with glutathione, cysteine, cysteinyl-glycine, cysteinyl-glutamate and homocysteine.

  2. Phosphorylation and activation of the plasma membrane Na+/H+ exchanger (NHE1 during osmotic cell shrinkage.

    Directory of Open Access Journals (Sweden)

    Robert R Rigor

    Full Text Available The Na(+/H(+Exchanger isoform 1 (NHE1 is a highly versatile, broadly distributed and precisely controlled transport protein that mediates volume and pH regulation in most cell types. NHE1 phosphorylation contributes to Na(+/H(+ exchange activity in response to phorbol esters, growth factors or protein phosphatase inhibitors, but has not been observed during activation by osmotic cell shrinkage (OCS. We examined the role of NHE1 phosphorylation during activation by OCS, using an ideal model system, the Amphiuma tridactylum red blood cell (atRBC. Na(+/H(+ exchange in atRBCs is mediated by an NHE1 homolog (atNHE1 that is 79% identical to human NHE1 at the amino acid level. NHE1 activity in atRBCs is exceptionally robust in that transport activity can increase more than 2 orders of magnitude from rest to full activation. Michaelis-Menten transport kinetics indicates that either OCS or treatment with the phosphatase inhibitor calyculin-A (CLA increase Na(+ transport capacity without affecting transport affinity (K(m=44 mM in atRBCs. CLA and OCS act non-additively to activate atNHE1, indicating convergent, phosphorylation-dependent signaling in atNHE1 activation. In situ(32P labeling and immunoprecipitation demonstrates that the net phosphorylation of atNHE1 is increased 4-fold during OCS coinciding with a more than 2-order increase in Na(+ transport activity. This is the first reported evidence of increased NHE1 phosphorylation during OCS in any vertebrate cell type. Finally, liquid chromatography and mass spectrometry (LC-MS/MS analysis of atNHE1 immunoprecipitated from atRBC membranes reveals 9 phosphorylated serine/threonine residues, suggesting that activation of atNHE1 involves multiple phosphorylation and/or dephosphorylation events.

  3. Direct analysis of ultra-trace semiconductor gas by inductively coupled plasma mass spectrometry coupled with gas to particle conversion-gas exchange technique.

    Science.gov (United States)

    Ohata, Masaki; Sakurai, Hiromu; Nishiguchi, Kohei; Utani, Keisuke; Günther, Detlef

    2015-09-01

    An inductively coupled plasma mass spectrometry (ICPMS) coupled with gas to particle conversion-gas exchange technique was applied to the direct analysis of ultra-trace semiconductor gas in ambient air. The ultra-trace semiconductor gases such as arsine (AsH3) and phosphine (PH3) were converted to particles by reaction with ozone (O3) and ammonia (NH3) gases within a gas to particle conversion device (GPD). The converted particles were directly introduced and measured by ICPMS through a gas exchange device (GED), which could penetrate the particles as well as exchange to Ar from either non-reacted gases such as an air or remaining gases of O3 and NH3. The particle size distribution of converted particles was measured by scanning mobility particle sizer (SMPS) and the results supported the elucidation of particle agglomeration between the particle converted from semiconductor gas and the particle of ammonium nitrate (NH4NO3) which was produced as major particle in GPD. Stable time-resolved signals from AsH3 and PH3 in air were obtained by GPD-GED-ICPMS with continuous gas introduction; however, the slightly larger fluctuation, which could be due to the ionization fluctuation of particles in ICP, was observed compared to that of metal carbonyl gas in Ar introduced directly into ICPMS. The linear regression lines were obtained and the limits of detection (LODs) of 1.5 pL L(-1) and 2.4 nL L(-1) for AsH3 and PH3, respectively, were estimated. Since these LODs revealed sufficiently lower values than the measurement concentrations required from semiconductor industry such as 0.5 nL L(-1) and 30 nL L(-1) for AsH3 and PH3, respectively, the GPD-GED-ICPMS could be useful for direct and high sensitive analysis of ultra-trace semiconductor gas in air.

  4. Development of the gas puff charge exchange recombination spectroscopy (GP-CXRS) technique for ion measurements in the plasma edge

    Energy Technology Data Exchange (ETDEWEB)

    Churchill, R. M.; Theiler, C.; Lipschultz, B. [MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139 (United States); Dux, R.; Pütterich, T.; Viezzer, E. [Max-Planck-Institut für Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany); Collaboration: Alcator C-Mod Team; ASDEX Upgrade Team

    2013-09-15

    A novel charge-exchange recombination spectroscopy (CXRS) diagnostic method is presented, which uses a simple thermal gas puff for its donor neutral source, instead of the typical high-energy neutral beam. This diagnostic, named gas puff CXRS (GP-CXRS), is used to measure ion density, velocity, and temperature in the tokamak edge/pedestal region with excellent signal-background ratios, and has a number of advantages to conventional beam-based CXRS systems. Here we develop the physics basis for GP-CXRS, including the neutral transport, the charge-exchange process at low energies, and effects of energy-dependent rate coefficients on the measurements. The GP-CXRS hardware setup is described on two separate tokamaks, Alcator C-Mod and ASDEX Upgrade. Measured spectra and profiles are also presented. Profile comparisons of GP-CXRS and a beam based CXRS system show good agreement. Emphasis is given throughout to describing guiding principles for users interested in applying the GP-CXRS diagnostic technique.

  5. Analysis of amphetamine-type stimulants and their metabolites in plasma, urine and bile by liquid chromatography with a strong cation-exchange column-tandem mass spectrometry.

    Science.gov (United States)

    Kuwayama, Kenji; Inoue, Hiroyuki; Kanamori, Tatsuyuki; Tsujikawa, Kenji; Miyaguchi, Hajime; Iwata, Yuko T; Miyauchi, Seiji; Kamo, Naoki

    2008-05-01

    The aim of this work was to develop and validate a method for analysing amphetamine-type stimulants (ATSs) and their metabolites in plasma, urine and bile by liquid chromatography with a strong cation-exchange column-tandem mass spectrometry, and to apply it to the pharmacokinetic study of ATSs. 3,4-Methylenedioxymethamphetamine, methamphetamine, ketamine and their main metabolites, 4-hydroxy-3-methoxymethamphetamine, 3,4-methylenedioxyamphetamine, p-hydroxymethamphetamine, amphetamine and norketamine, were simultaneously quantified by the new method (50-5000 ng/ml). The coefficients of variation and the percent deviations for the eight compounds were in the range of 0.2 to 5.3% and -9.4 to +12.8%, respectively. The recoveries were over 90% in all biological samples tested. This method was effective for the separation and the identification of ATSs and their main metabolites having amine moieties in plasma, urine and bile, and was applicable to pharmacokinetic analysis of methamphetamine, ketamine and their main metabolites in biological samples. This analytical method should be useful for the pharmacokinetic analysis of ATSs.

  6. Filtration as the main transport mechanism of protein exchange between plasma and the peritoneal cavity in hepatic cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Lassen, N A; Parving, H H;

    1980-01-01

    with carcinomatous ascites. Trans-vascular escape rates of albumin (TERa) and IgG (TERg) were determined in the cirrhotic patients from the disappearance of simultaneously intravenously injected 131I-labelled serum albumin and 124I-labelled IgG. Peritoneal space to plasma appearance times ranged 0.1-3.3 h......, but significantly higher (P TERa and TERg were on average 9.6 and 8.6% of intravascular protein masses per hour, mean TERg/TERa ratio was 0.95. Peritoneal space...

  7. STEC:O111-HUS complicated by acute encephalopathy in a young girl was successfully treated with a set of hemodiafiltration, steroid pulse, and soluble thrombomodulin under plasma exchange.

    Science.gov (United States)

    Yada, Noritaka; Fujioka, Masayuki; Bennett, Charles L; Inoki, Kazuya; Miki, Toyokazu; Watanabe, Akihiko; Yoshida, Toshiko; Hayakawa, Masaki; Matsumoto, Masanori; Fujimura, Yoshihiro

    2015-04-01

    We report a 14-year-old girl, who developed shigatoxin-producing E. coli (STEC)-HUS complicated by encephalopathy. She was successfully treated with hemodiafiltration, high-dose methylprednisolone pulse therapy, and soluble recombinant thrombomodulin under plasma exchange. von Willebrand factor multimers analysis provides potential insights into how the administered therapies might facilitate successful treatment of STEC-HUS.

  8. Clinical Study on Treatment of Gouty Arthritis with Plasma Exchange%血浆置换疗法在痛风性关节炎治疗中的应用

    Institute of Scientific and Technical Information of China (English)

    应美爱; 陈家萍; 叶书来

    2009-01-01

    目的 观察治疗性血浆置换治疗痛风性关节炎的临床疗效.方法 采用血浆置换法治疗17例痛风性关节炎患者,比较置换前后患者血尿酸(UA)、C-反应性蛋白(CRP)、血沉(ESR)的变化及临床症状的改善.结果 17例患者经血浆置换后血尿酸、C-反应蛋白、血沉明显降低(P<0.01);临床症状明显好转,关节红、肿、热、痛症状消失.结论 血浆置换结合药物治疗痛风性关节炎的疗效显著.%Objective To study the clinical effect of plasma exchange in the treatment of gouty arthritis. Methods Seventeen patients with gouty arthritis were treated with plasma exchange.Results In 17 patients,the clinical symptoms were significantly ameliorated after treatment with plasma exchange. The contents of uric acid(UA),C-reactive protein(CRP) and erythrocyte sedimentation rate (ESR) descended after the treatment. Conclusion The plasma exchange is a reliable therapy or gouty arthritis.

  9. Therapeutic Plasma Exchange May Improve Hemodynamics and Organ Failure Among Children with Sepsis-Induced Multiple Organ Dysfunction Syndrome Receiving Extracorporeal Life Support

    Science.gov (United States)

    Kawai, Yu; Cornell, Timothy T.; Cooley, Elaine G.; Beckman, Craig N.; Baldridge, Paula K.; Mottes, Theresa A.; Luckritz, Kera E.; Plomaritas, Kathryn S.; Meade, J. Michael; Odetola, Folafoluwa O.; Han, Yong Y.; Blatt, Neal B.; Annich, Gail M.

    2014-01-01

    Objective To determine the effect of therapeutic plasma exchange (TPE) on hemodynamics, organ failure, and survival in children with multiple organ dysfunction syndrome (MODS) due to sepsis requiring extracorporeal life support (ECLS). Design A retrospective analysis. Setting A pediatric intensive care unit (PICU) in an academic children’s hospital. Patients 14 consecutive children with sepsis and MODS who received TPE while on ECLS from 2005 to 2013. Interventions Median of 3 cycles of TPE with median of 1.0 times the estimated plasma volume per exchange. Measurements and Main Results Organ Failure Index (OFI) and Vasoactive-Inotropic Score (VIS) were measured before and after TPE use. PICU survival in our cohort was 71.4%. OFI decreased in patients following TPE [pre: 4.1 ± 0.7 vs. post: 2.9 ± 0.9 (mean ±SD); p = 0.0004]. Patients showed improved VIS following TPE [pre: 24.5 (13.0–69.8) vs. post: 5.0 (1.5–7.0), median (25th–75th); p = 0.0002]. Among all patients, the change in OFI was greater for early TPE use than late use [pre: −1.7 ±1.2 vs. post: −0.9 ±0.6; p = 0.14], similar to the change in VIS [pre: −67.5 (28.0–171.2) vs. post: −12.0 (7.2–18.5); p = 0.02]. Among survivors, the change in OFI was greater among early TPE use than late use [early: −2.3 ±1.0 vs. late: −0.8 ± 0.8; p = 0.03], as was the change in VIS [early: −42.0 (16.0–76.3) vs. late: −12.0 (5.3–29.0); p=0.17]. The mean duration of ECLS after TPE according to timing of TPE was not statistically different among all patients or among survivors. Conclusions The use of TPE in children on ECLS with sepsis-induced MODS is associated with organ failure recovery and improved hemodynamic status. Initiating TPE early in the hospital course was associated with greater improvement in organ dysfunction and decreased requirement for vasoactive and/or inotropic agents. PMID:25599148

  10. Successful long-term (22 year) treatment of limited scleroderma using therapeutic plasma exchange: Is blood rheology the key?

    Science.gov (United States)

    Harris, Edward S; Meiselman, Herbert J; Moriarty, Patrick M; Weiss, John

    2017-01-01

    While a number of studies have shown short-term beneficial effects of therapeutic plasma exchange (TPE) for treating systemic scleroderma (SSc), there have been no reports on the very long-term usage of TPE as the sole systemic treatment intervention. We report the case of a male patient, originally diagnosed with limited systemic scleroderma (lcSSc) in early 1990, who has been undergoing regular plasmapheresis treatments for more than 22 years, beginning in late 1993. Prior to commencing treatment, the patient exhibited symptoms including severe gastro esophageal reflux disease (GERD) with esophagitis, frequent Raynaud's attacks, reduced lung function, and chronic chilling. With the exception of mild residual Raynaud's, all of the patient's symptoms reversed after three years of regular TPE treatments and he remains in complete remission. While the typical explanation for the therapeutic benefits seen with TPE focuses on temporary reduction of circulating antibodies or other pathogenic factors, we propose instead an explanation based on abnormal blood rheology as a novel disease pathogenesis model for SSc.

  11. Plasma exchange in management of skin diseases%血浆置换疗法在皮肤病中的应用

    Institute of Scientific and Technical Information of China (English)

    林俊萍; 高兴华

    2000-01-01

    @@ 血浆置换疗法(plasma exchange,PE)是一种体外净化(apheresis)方法,通过血细胞分离机、分离膜等去除血浆中的致病因子,如特异性自身抗体、参与组织损伤的非特异性炎症介质(补体、C反应蛋白、纤维蛋白原等)、免疫复合物、胆固醇、巨球蛋白、毒性代谢产物、微生物及其代谢产物等,同时补充适量的正常人血浆、白蛋白或代血浆,从而发挥治疗作用.血浆去除术(plasmapheresis)系指通过在体外去除血浆来治疗疾病的方法.目前PE和血浆去除术已被作为同义词使用.

  12. Chiral resolution of salbutamol in plasma sample by a new chiral ligand-exchange chromatography method after its extraction with nano-sized imprinted polymer.

    Science.gov (United States)

    Alizadeh, Taher; Shamkhali, Amir Naser

    2016-01-15

    A new chromatographic procedure, based upon chiral ligand-exchange principal, was developed for the resolution of salbutamol enantiomers. The separation was carried out on a C18 column. (l)-Alanine and Cu(2+) were applied as chiral resolving agent and complexing ion, respectively. The kind of copper salt had definitive effect on the enantioseparation. Density functional theory (DFT) was used to substantiate the effect of various anions, accompanying Cu(2+), on the formation of ternary complexes, assumed to be created during separation process. The DFT results showed that the anion kind had huge effect on the stability difference between two corresponding diastereomeric complexes and their chemical structures. It was shown that the extent of participation of the chiral selector in the ternary diastereomeric complexes formation was managed by the anion kind, affecting thus the enantioseparation efficiency of the developed method. Water/methanol (70:30) mixture containing (l)-alanine-Cu(2+) (4:1) was found to be the best mobile phase for salbutamol enantioseparation. In order to analyze sulbutamol enantiomers in plasma samples, racemic salbutamol was first extracted from the samples via nano-sized salbutamol-imprinted polymer and then enantioseparated by the developed method.

  13. Twice-daily therapeutical plasma exchange-based salvage therapy in severe autoimmune thrombotic thrombocytopenic purpura: the French TMA Reference Center experience.

    Science.gov (United States)

    Soucemarianadin, Myriam; Benhamou, Ygal; Delmas, Yahsou; Pichereau, Claire; Maury, Eric; Pène, Frédéric; Halimi, Jean-Michel; Presne, Claire; Thouret, Jean-Marc; Veyradier, Agnès; Coppo, Paul

    2016-08-01

    Daily therapeutic plasma exchange (TPE) and rituximab improved thrombotic thrombocytopenic purpura (TTP) prognosis. In the more severe cases, salvage therapies including twice-daily TPE and/or cyclophosphamide may be proposed and require evaluation. TTP was defined as a thrombotic microangiopathy (TMA) with severe (TMA registry, we considered those with a severe disease (i.e., unresponsive to daily TPE and rituximab) who received twice-daily TPE. Nineteen of 289 (6.6%) patients with TTP were treated by twice-daily TPE between 2008 and 2014. Twice-daily TPE was associated with rituximab in 16 cases. The median duration of twice-daily TPE treatment was 3 d (2-22 d). In 6 patients (31.6%), additional treatments (mainly pulses of cyclophosphamide) were performed because of a persistently refractory disease (4 cases) or an exacerbation (2 cases), despite twice-daily TPE. Only one patient (5.3%) died. The other 18 achieved a durable complete remission 25.5 d (13-68 d) after the first TPE. The median follow-up was 14.4 months (7 d-45 months). Twice-daily TPE may be an efficient strategy in the more severe TTP patients with a short-term life-threatening disease that could overcome their poor prognosis. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Longitudinal relationships between fluid status, inflammation, urine volume and plasma metabolites of icodextrin in patients randomized to glucose or icodextrin for the long exchange.

    Science.gov (United States)

    Davies, Simon J; Garcia Lopez, Elvia; Woodrow, Graham; Donovan, Kieron; Plum, Jorg; Williams, Paul; Johansson, Ann Catherine; Bosselmann, Hans-Peter; Heimburger, Olof; Simonsen, Ole; Davenport, Andrew; Lindholm, Bengt; Tranaeus, Anders; Divino Filho, Jose C

    2008-09-01

    Randomized trials have shown that icodextrin reduces the volume of extra-cellular fluid (ECFv) with variable effects on residual renal function. To explore this fluid shift and its possible mechanisms in more detail, prospectively collected data from one such trial, including measures of inflammation (C-reactive protein, tumour necrosis factor-alpha, albumin and low and high molecular weight hyaluronan) ANP (atrial naturetic peptide), an indirect marker of intra-vascular volume, plasma concentrations of icodextrin metabolites and alpha-amylase activity were analysed. 50 patients were randomized to either 2.27% glucose or icodextrin (n = 28) for a long exchange following a month run in. Blood samples were obtained at -1, 0, 3 and 6 months, coincident with measurements of urine volume and fluid status. In both randomized groups, a significant correlation between the fall in ECFv and the decline in urine volume was observed (P = 0.001), although the relative drop in urine volume for patients randomized to icodextrin tended to be less. At baseline, ANP was higher in patients with proportionately more ECFv for a given body water or height. Icodextrin patients had non-significantly higher ANP levels at baseline, whereas by 3 (P = 0.026) and 6 months (P = 0.016) these differed between groups due to divergence. There was a correlation between increasing ANP and reduced ECF at 3 months, r = -0.46, P = 0.007, in patients randomized to icodextrin, but not glucose. There were no relationships between fluid status and any inflammatory markers at any point of the study, with the exception of albumin at baseline, r = -0.39, P = 0.007. Amylase activities at -1 month and baseline were highly correlated, r = 0.89, P volume, fluid or inflammatory status. This analysis supports observational data that changes in fluid status are associated with changes in urine volume. Icodextrin was not associated with a greater fall in urine output despite its larger effect on ECFv. Changes in fluid

  15. 血浆置换在神经系统疾病中的应用%Plasma exchange in the treatment of neurological diseases: analysis of 78 cases

    Institute of Scientific and Technical Information of China (English)

    母艳蕾; 张华

    2012-01-01

    目的 回顾分析血浆置换(plasma exchange,PE)治疗神经免疫性疾病患者的资料,了解其疗效和不良反应. 方法 对78例应用PE换治疗过的患者资料回顾性分析,其中包括73例重症肌无力(myasthenia gravis,MG),3例吉兰巴雷综合征(Guillain-Barre' syndrome,GBS),1 例慢性炎性脱髓鞘性多神经根神经病(chronic inflammatory demyelinating polyneuropathy,CIDP)和1例多发性硬化(multiple sclerosis,MS).PE头3次为隔日1次,之后为隔周1次,偶有1周2次.应用临床评分观察疗效,根据临床记录了解有关副反应.结果 73例MG患者PE后第3d、第14d和第30d临床绝对评分明显降低,差异具有统计学意义.PE对3例GBS和1例CIDP患者疗效肯定,1例MS患者行双重置换(double filtration plasmapheresis,therapy,DFPP)后临床症状改善不明显,以上患者在PE治疗过程中未见严重不良反应. 结论 PE在多数神经系统免疫疾病如MG、GBS和CIDP疗效肯定,不良反应较少.在治疗中枢神经系统脱髓鞘病(例如MS等)的情况有待进一步观察.%Objectives To assess the efficacy and side effects of plasma exchange (PE) in the treatment of myasthenia gravis (MG), Guillain-Barre syndrome (GBS), chronic inflammatory demyelination polyneuropathy (CIDP) and multiple sclerosis (MS) patients. Methods We retrospectively reviewed 78 neurological patients treated with PE, including MG 73 cases, GBS 3 cases, CIDP one case and MS one case. PE was performed every other day for 3 times, and then once a week (or twice a week for some patients). Efficacy was evaluated by clinical scales assessed before and after PE, and the side effects were recorded. Results In the 73 MG cases, the scores of absolute scale for clinical signs after PE for 3, 14 and 30 days were statistically lower than the score before PE. In the 3 GBS and one CIDP cases, PE was effective in shortening recovery period and improving disability. In the MS case, no prominent improvement was detected after

  16. Plasma exchange-centered artiifcial liver support system in hepatitis B virus-related acute-on-chronic liver failure:a nationwide prospective multicenter study in China

    Institute of Scientific and Technical Information of China (English)

    Jia-Jia Chen; Jian-He Gan; Zhi-Liang Gao; Yu-Ming Wang; Shu-Mei Lin; Qing Xie; Chen Pan; Lan-Juan Li; Jian-Rong Huang; Qian Yang; Xiao-Wei Xu; Xiao-Li Liu; Shao-Rui Hao; Hui-Fen Wang; Tao Han; Jing Zhang

    2016-01-01

    BACKGROUND: Plasma exchange (PE)-centered artiifcial liver support system reduced the high mortality rate of hepa-titis B virus (HBV)-related acute-on-chronic liver failure (ACLF). But the data were diverse in different medical centers. The present prospective nationwide study was to evaluate the effects of PE on patients with HBV-ACLF at different stages. METHODS: From December 2009 to December 2011, we eval-uated 250 patients at different stages of HBV-ACLF from 10 major medical centers in China. All the laboratory parameters were collected at admission, before and after PE. RESULTS: Among the 250 patients who underwent 661 rounds of PE, one-month survival rate was 61.6%; 141 (56.4%) showed improvement after PE. Variables such as age (P=0.000), levels of total bilirubin (TB,P=0.000), direct bilirubin (P=0.000), total triglycerides (P=0.000), low-density lipoprotein (P=0.022), Na+ (P=0.014), Cl– (P=0.038), creatinine (Cr,P=0.007), ifbrinogen (P=0.000), prothrombin time (PT,P=0.000), white blood cell (P=0.000), platelet (P=0.003) and MELD (P=0.000) were signiifcantly related to prognosis. Multivariate logistic regression analysis showed that age, disease stage, TB, Cr and PT levels were independent risk factors of mortality among HBV-ACLF patients. CONCLUSIONS: PE can improve the clinical outcome of pa-tients with HBV-ACLF. Levels of TB, Cr and PT, age and disease stage help to predict prognosis.

  17. Plasma exchange-centered artiifcial liver support system in hepatitis B virus-related acute-on-chronic liver failure:a nationwide prospective multicenter study in China

    Institute of Scientific and Technical Information of China (English)

    Jia-Jia Chen; Jian-He Gan; Zhi-Liang Gao; Yu-Ming Wang; Shu-Mei Lin; Qing Xie; Chen Pan; Lan-Juan Li; Jian-Rong Huang; Qian Yang; Xiao-Wei Xu; Xiao-Li Liu; Shao-Rui Hao; Hui-Fen Wang; Tao Han; Jing Zhang

    2015-01-01

    BACKGROUND: Plasma exchange (PE)-centered artiifcial liver support system reduced the high mortality rate of hepa-titis B virus (HBV)-related acute-on-chronic liver failure (ACLF). But the data were diverse in different medical centers. The present prospective nationwide study was to evaluate the effects of PE on patients with HBV-ACLF at different stages. METHODS: From December 2009 to December 2011, we eval-uated 250 patients at different stages of HBV-ACLF from 10 major medical centers in China. All the laboratory parameters were collected at admission, before and after PE. RESULTS: Among the 250 patients who underwent 661 rounds of PE, one-month survival rate was 61.6%; 141 (56.4%) showed improvement after PE. Variables such as age (P=0.000), levels of total bilirubin (TB,P=0.000), direct bilirubin (P=0.000), total triglycerides (P=0.000), low-density lipoprotein (P=0.022), Na+ (P=0.014), Cl– (P=0.038), creatinine (Cr,P=0.007), ifbrinogen (P=0.000), prothrombin time (PT,P=0.000), white blood cell (P=0.000), platelet (P=0.003) and MELD (P=0.000) were signiifcantly related to prognosis. Multivariate logistic regression analysis showed that age, disease stage, TB, Cr and PT levels were independent risk factors of mortality among HBV-ACLF patients. CONCLUSIONS: PE can improve the clinical outcome of pa-tients with HBV-ACLF. Levels of TB, Cr and PT, age and disease stage help to predict prognosis.

  18. Response to Therapeutic Plasma Exchange as a Rescue Treatment in Clinically Isolated Syndromes and Acute Worsening of Multiple Sclerosis: A Retrospective Analysis of 90 Patients.

    Directory of Open Access Journals (Sweden)

    Johannes Ehler

    Full Text Available Experience with therapeutic plasma exchange (TPE for acute relapses in clinically isolated syndrome (CIS or multiple sclerosis (MS patients has been derived from small and inhomogeneous patient populations so far. In the present study, we retrospectively evaluated features associated with TPE response in a larger cohort of CIS and MS patients with acute worsening of disease.Ninety CIS and MS patients with acute relapses or acute worsening of symptoms were firstly treated with TPE. The population consisted of 62 women and 28 men with a median age of 38 years (range 18-69 years.Primary endpoint was the clinical response to TPE, focused on the functional improvement of the target neurologic deficit. Secondary endpoint was an improvement in expanded disability status scale (EDSS scoring.A clinical response to TPE was observed in 65 out of 90 patients (72.2%, with marked improvement in 18 (20.0% and moderate improvement in 47 out of 90 patients (52.2%. The median EDSS was reduced from 3.75 before to 3.0 after TPE (p = 0.001. Response to TPE was significantly more frequent in patients with relapsing courses of disease (CIS, RR-MS, p = 0.001, no disease modifying drugs (p = 0.017, gadolinium-positive (Gd+ MRI lesions (p = 0.001 and EDSS ≤ 5.0 before TPE (p = 0.014. In the multiple logistic regression analysis only the detection of Gd+ MRI lesions was significantly altered (p = 0.004.Clinical response to TPE was achieved in the majority of our patients. We identified clinical and diagnostic features in CIS and MS relapses that might be helpful to identify patients responding to TPE. Gd+ MRI lesions before treatment were the best predictor of the response to TPE in our cohort.

  19. COMBINED PLASMA FILTRATION, SELECTIVE ADSORPTION OF CYTOKINES WITH HEMOFILTRATION AND PLASMA EXCHANGE IN THE CORRECTION OF PLATELET AND COAGULATION HEMOSTASIS IN PATIENTS WITH THE SYNDROME OF DISSEMINATED INTRAVASCULAR COAGULATION

    Directory of Open Access Journals (Sweden)

    L. V. Belskikh

    2015-01-01

    value or continued to increase progressively. In this subgroup of the patients purulent complications progressed in 9 patients, mortality was 35%. Conclusion. Thus, the level of thrombocyte hemostasis in different phases of pancreatic necrosis can be quantified using indicators of morphofunctional status of circulating platelets. When dealing with coagulation version of disseminated intravascular coagulation syndrome the number of activated cells is on the rise up to 40% or more. The development of consumption coagulopathy is characterized with progressive increase of degenerative platelets up to 10% or more. Combined plasma filtration, selective adsorption of cytokines with hemofiltration and exchange plasmapheresis are effective methods for adjusting of platelet and coagulation hemostasis in patients with necrotizing pancreatitis.

  20. Retrospective analysis of plasma exchange combined with glucocorticosteroids for the treatment of systemic lupus erythematosus-related acute pancreatitis in central China.

    Science.gov (United States)

    Yu, Yi-Kai; Yu, Fei; Ye, Cong; Dai, Yu-Jie; Huang, Xiao-Wei; Hu, Shao-Xian

    2016-08-01

    Systemic lupus erythematosus-related acute pancreatitis (SLEAP) has a poor prognosis with a high mortality. We described the clinical features of SLEAP, and discussed the feasibility of plasma exchange (PE) combined with glucocorticosteroids (GC) in short-term prognosis and possible mechanism in reducing serum inflammatory cytokine IL-6 and removing serum lipids. A retrospective study was performed by an independent rheumatologist. Medical records of SLEAP from March 2010 to December 2014 were retrieved from Tongji Hospital information system, and patients were divided into two groups according to whether PE therapy was adopted. Sixteen patients treated with PE in combination with GC were classified as group A, and the other 10 patients who were treated with merely GC were classified as group B. Patients' clinical remission rate and average daily GC dosage after two-week therapy were compared between the two groups. Patients' serum inflammatory cytokines and lipid concentration were compared between baseline and after two-week treatment in both groups. Pearson correlation test was performed to determine association between serum cytokines and Ranson score. SLEDAI score in group A patients at baseline (14.8±3.1) showed no statistical difference from that in group B (14.1±3.3). At baseline serum IL-6 levels had no significant difference between group A [13.14 (11.12, 16.57) mg/L] and group B [14.63 (11.37, 16.37) mg/L]; after two-week therapy IL-6 decreased significantly in group A [9.16 (7.93, 10.75)mg/L] while it did not show decreasing trend in group B [13.62 (9.29,17.63) mg/L]. Serum lipid concentration after two-week therapy in group A [(TC=5.02±0.53, TG=1.46±0.44) mmol/L] decreased significantly compared to baseline [(TC=6.11±0.50, TG=2.14±1.03) mmol/L], while similar tendency was not observed in group B. The remission rate after two-week therapy was higher in group A (70.0%) than in group B (25.0%). Acute pancreatitis (AP) was one of the clinical

  1. The prevention and nursing for the complications of 25 patients with plasma exchange%25例患者血浆置换过程中并发症的预防与护理

    Institute of Scientific and Technical Information of China (English)

    赵茜芸

    2015-01-01

    目的:探讨血浆置换在临床应用中常见并发症的相关原因、预防及护理对策,保证临床血浆置换治疗的顺利完成。方法对本组25例患者进行血浆置换共53次,采用Prismaflex系统CRRT机,TPE-2000血浆分离器,将患者含有毒素或致病物质的血浆分离出来,同时代之以1000~3000mL新鲜冰冻血浆,通过对治疗过程中并发症的的观察,总结出并发症的发生原因,并及时制定相应的预防及护理措施。结果25例患者中有1例患者出现过敏反应;1例出现低血压;1例发生低血钙;未见穿刺针脱出滑出、出血倾向及感染等严重并发症的发生。结论掌握熟练的操作技术和术中的密切观察护理可以预防血浆置换并发症的发生,是保证血浆置换顺利完成的关键。%ObjectiveTo investigate the related causes, prevention and nursing countermeasure of common complications in the clinical application of plasma exchange and then guarantee the completion of clinical plasma exchange treatment.Methods This group contains 25 cases of patients who have been operated with plasma exchange at 53 times totally. The Prismaflex system CRRT machine and TPE-2000 plasma separator were used to separate patients serum containing toxins or pathogenic substance, replacing with 1000 to 3000 mL fresh frozen plasma. It is expected to summarize the causes resulting in the complications from the observation in the process of treatment, and make corresponding measurements to prevent and nurse. Results Among 25 cases of patients, it appeared allergic reaction for 1 case; developed hypotension for 1 case and 1 case of low blood calcium; No serious complications were observed such as puncture needle dropping out, bleeding tendency, and infection.Conclusion It could be achieved to prevent the occurrence of complications in plasma exchange via the skilled operation techniques and the close observation and nursing in operation, which are

  2. Rapid isolation of plutonium in environmental solid samples using sequential injection anion exchange chromatography followed by detection with inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Qiao Jixin, E-mail: jixin.qiao@risoe.d [Radiation Research Division, Riso National Laboratory for Sustainable Energy, Technical University of Denmark, DK-4000 Roskilde (Denmark); Hou Xiaolin; Roos, Per [Radiation Research Division, Riso National Laboratory for Sustainable Energy, Technical University of Denmark, DK-4000 Roskilde (Denmark); Miro, Manuel [Department of Chemistry, Faculty of Sciences, University of the Balearic Islands, Carretera de Valldemossa km. 7.5, E-07122 Palma de Mallorca, Illes Balears (Spain)

    2011-01-31

    This paper reports an automated analytical method for rapid determination of plutonium isotopes ({sup 239}Pu and {sup 240}Pu) in environmental solid extracts. Anion exchange chromatographic columns were incorporated in a sequential injection (SI) system to undertake the automated separation of plutonium from matrix and interfering elements. The analytical results most distinctly demonstrated that the crosslinkage of the anion exchanger is a key parameter controlling the separation efficiency. AG 1-x4 type resin was selected as the most suitable sorbent material for analyte separation. Investigation of column size effect upon the separation efficiency revealed that small-sized (2 mL) columns sufficed to handle up to 50 g of environmental soil samples. Under the optimum conditions, chemical yields of plutonium exceeded 90% and the decontamination factors for uranium, thorium and lead ranged from 10{sup 3} to 10{sup 4}. The determination of plutonium isotopes in three standard/certified reference materials (IAEA-375 soil, IAEA-135 sediment and NIST-4359 seaweed) and two reference samples (Irish Sea sediment and Danish soil) revealed a good agreement with reference/certified values. The SI column-separation method is straightforward and less labor intensive as compared with batch-wise anion exchange chromatographic procedures. Besides, the automated method features low consumption of ion-exchanger and reagents for column washing and elution, with the consequent decrease in the generation of acidic waste, thus bearing green chemical credentials.

  3. Rapid isolation of plutonium in environmental solid samples using sequential injection anion exchange chromatography followed by detection with inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per; Miró, Manuel

    2011-01-31

    This paper reports an automated analytical method for rapid determination of plutonium isotopes ((239)Pu and (240)Pu) in environmental solid extracts. Anion exchange chromatographic columns were incorporated in a sequential injection (SI) system to undertake the automated separation of plutonium from matrix and interfering elements. The analytical results most distinctly demonstrated that the crosslinkage of the anion exchanger is a key parameter controlling the separation efficiency. AG 1-×4 type resin was selected as the most suitable sorbent material for analyte separation. Investigation of column size effect upon the separation efficiency revealed that small-sized (2 mL) columns sufficed to handle up to 50 g of environmental soil samples. Under the optimum conditions, chemical yields of plutonium exceeded 90% and the decontamination factors for uranium, thorium and lead ranged from 10(3) to 10(4). The determination of plutonium isotopes in three standard/certified reference materials (IAEA-375 soil, IAEA-135 sediment and NIST-4359 seaweed) and two reference samples (Irish Sea sediment and Danish soil) revealed a good agreement with reference/certified values. The SI column-separation method is straightforward and less labor intensive as compared with batch-wise anion exchange chromatographic procedures. Besides, the automated method features low consumption of ion-exchanger and reagents for column washing and elution, with the consequent decrease in the generation of acidic waste, thus bearing green chemical credentials.

  4. High-throughput sequential injection method for simultaneous determination of plutonium and neptunium in environmental solids using macroporous anion-exchange chromatography, followed by inductively coupled plasma mass spectrometric detection.

    Science.gov (United States)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per; Miró, Manuel

    2011-01-01

    This paper reports an automated analytical method for rapid and simultaneous determination of plutonium and neptunium in soil, sediment, and seaweed, with detection via inductively coupled plasma mass spectrometry (ICP-MS). A chromatographic column packed with a macroporous anion exchanger (AG MP-1 M) was incorporated in a sequential injection (SI) system for the efficient retrieval of plutonium, along with neptunium, from matrix elements and potential interfering nuclides. The sorption and elution behavior of plutonium and neptunium onto AG MP-1 M resin was compared with a commonly utilized AG 1-gel-type anion exchanger. Experimental results reveal that the pore structure of the anion exchanger plays a pivotal role in ensuring similar separation behavior of plutonium and neptunium along the separation protocol. It is proven that plutonium-242 ((242)Pu) performs well as a tracer for monitoring the chemical yield of neptunium when using AG MP-1 M resin, whereby the difficulties in obtaining a reliable and practicable isotopic neptunium tracer are overcome. An important asset of the SI setup is the feasibility of processing up to 100 g of solid substrates using a small-sized (ca. 2 mL) column with chemical yields of neptunium and plutonium being ≥79%. Analytical results of three certified/standard reference materials and two solid samples from intercomparison exercises are in good agreement with the reference values at the 0.05 significance level. The overall on-column separation can be completed within 3.5 h for 10 g of soil samples. Most importantly, the anion-exchange mini-column suffices to be reused up to 10-fold with satisfactory chemical yields (>70%), as demanded in environmental monitoring and emergency scenarios, making the proposed automated assembly well-suited for unattended and high-throughput analysis.

  5. Clinical study on plasma exchange in treatment of Guillain - Barre syndrome in 15 cases.%血浆置换治疗格林巴利综合征15例临床分析

    Institute of Scientific and Technical Information of China (English)

    赖芳芳

    2011-01-01

    Objective To study the effect of plasma exchange therapy in treatment of Guillain - Barre syndrome. Methods The clinical effectiveness of plasna exchange in treatment of fifteen patients with Guillain - Barre syndrome had been observed, and the evaluation of its therapeutic effect through the detection of concentration of antibody and complement was carried out. Results After the treatment of plasna exchange,neurological function of these patients were significantly improved. Among them, three cases cured, 7 cases with excellent effectiveness and 4 with effectiveness. Antibody and complement in their plasna were significantly decreased in comparison with those before the treatment, and their difference was significant ( P < 0.05 ). Conclusion The treatment with plasna exchange is an effective method for treatment of Guillain - Barre syndrome.%目的 探讨血浆置换疗法对格林巴利综合征的治疗效果.方法 对15例格林巴利综合征患者进行血浆置换治疗,观察其临床效果并检测患者血浆中抗体和补体的含量,评价其治疗效果.结果 血浆置换治疗后,患者神经功能明显改善,痊愈3例,显效7例,有效4例,无效1例,总有效率93.33%;血浆中抗体和补体含量明显降低,与治疗前比较差异有统计学意义(P<0.05).结论 血浆置换术是治疗格林巴利综合征较为有效的方法.

  6. Effect of nebulizer/spray chamber interfaces on simultaneous, axial view inductively coupled plasma optical emission spectrometry for the direct determination of As and Se species separated by ion exchange high-performance liquid chromatography

    Science.gov (United States)

    Gettar, Raquel T.; Smichowski, Patricia; Garavaglia, Ricardo N.; Farías, Silvia; Batistoni, Daniel A.

    2005-06-01

    Different nebulizer/expansion chamber combinations were evaluated to assess their performance for sample introduction in the direct coupling with an axial view inductively coupled plasma multielement spectrometer for on-line determination of As and Se species previously separated by ion exchange-high performance liquid chromatography. The column effluents were injected into the plasma without prior derivatization. The instrument operation software was adapted for data acquisition and processing to allow multi-wavelength recording of the transient chromatographic peaks. After optimization of the chromatographic operating conditions, separation of mixtures of inorganic As and Se species, and of inorganic and two organic As species (monomethylarsonic and dimethylarsinic acids), was achieved with excellent resolution. Species discrimination from mixtures of As and Se oxyanions was further improved by the simultaneous element detection at specific analytical wavelengths. Three nebulizers and three spray chambers, employed in seven combinations, were tested as interfaces. Concentric nebulizers associated to a glass cyclonic chamber appear most suitable regarding sensitivity and signal to noise ratio. Measured element detection limits (3 σ) were around 10 ng ml - 1 for all the species considered, making the method a viable alternative to similar procedures that employ volatile hydride generation previous to sample injection into the plasma. Analytical recoveries both for inorganic and organic species ranged between 92 and 107%. The method was demonstrated to be apt for the analysis of surface waters potentially subjected to natural contamination with arsenic.

  7. Efficacy observation of sequential plasma perfusion of low dose plasma exchange in patients with acute on chronic liver failure%小剂量血浆置换序贯血浆灌流对慢加急性肝衰竭患者疗效观察

    Institute of Scientific and Technical Information of China (English)

    吴刚; 陈文; 邓存良; 唐黎; 秦波

    2014-01-01

    Objective To investigate the clinical efficacy of sequential plasma perfusion of low dose plasma exchange in the pa-tients with acute on chronic liver failure (ACLF).Methods The patients with HBV related ACLF in the infection department of the Affiliated Hospital of Luzhou Medical College were divided into the plasma exchange therapy group (group A,n=114)and the low dose plasma exchange sequential plasma perfusion therapy group (group B,n=144).The group A was treated only by plasma exchange of fresh frozen plasma 2 400 mL;while the group B adopted the sequential plasma perfusion of plasma exchange,with fresh frozen plasma dosage of 1 400 mL.The changes of the liver and renal function,coagulation function and electrolyte indicators were observed in the two groups.The differences in the clinical effects and adverse reactions were compared between the two groups.Results The serum levels of ALT,TBIL and INR after treatment in the two groups were significant decreased than before treatment(P<0.05);ALB and PTA were significantly improved compared with before treatment(P<0.05);there were no signif-icant differences in serum levels of CRE,K+ and Na+ between before and after treatment.The changes of various indexes before and after treatment had no statistical differences between the two groups.The total effective rate and the mortality at 24 weeks in the group B was 66.66% and 47.22% respectively,which had no statistical differences compared with the group A.The total oc-currence rate of adverse reactions in the group B was 23.75%,which was significant lower than 35.26% in the group A with statis-tical difference (P=0.011).Conclusion Sequential plasma perfusion of plasma exchange has better clinical effect and few adverse reactions for treating the patients with ACLF,which can reduce the plasma dosage significantly.%目的:研究小剂量血浆置换序贯血浆灌流对慢加急性肝衰竭(ACLF)患者的临床疗效。方法病例来源于泸州医学

  8. Heat exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Craig, L.B.; Farma, A.J.

    1987-01-06

    This invention concerns a heat exchanger as used in a space heater, of the type in which hot exhaust gases transfer heat to water or the like flowing through a helical heat exchange coil. A significant improvement to the efficiency of the heat exchange occurring between the air and water is achieved by using a conduit for the water having external helical fluting such that the hot gases circulate along two paths, rather than only one. A preferred embodiment of such a heat exchanger includes a porous combustion element for producing radiant heat from a combustible gas, surrounded by a helical coil for effectively transferring the heat in the exhaust gas, flowing radially from the combustion element, to the water flowing through the coil. 4 figs.

  9. Role of the guanine nucleotide exchange factor in Akt2-mediated plasma membrane translocation of GLUT4 in insulin-stimulated skeletal muscle.

    Science.gov (United States)

    Takenaka, Nobuyuki; Yasuda, Naoto; Nihata, Yuma; Hosooka, Tetsuya; Noguchi, Tetsuya; Aiba, Atsu; Satoh, Takaya

    2014-11-01

    The small GTPase Rac1 plays a key role in insulin-promoted glucose uptake mediated by the GLUT4 glucose transporter in skeletal muscle. Our recent studies have demonstrated that the serine/threonine protein kinase Akt2 is critically involved in insulin-dependent Rac1 activation. The purpose of this study is to clarify the role of the guanine nucleotide exchange factor FLJ00068 in Akt2-mediated Rac1 activation and GLUT4 translocation in mouse skeletal muscle and cultured myocytes. Constitutively activated FLJ00068 induced GLUT4 translocation in a Rac1-dependent and Akt2-independent manner in L6 myocytes. On the other hand, knockdown of FLJ00068 significantly reduced constitutively activated Akt2-triggered GLUT4 translocation. Furthermore, Rac1 activation and GLUT4 translocation induced by constitutively activated phosphoinositide 3-kinase were inhibited by knockdown of FLJ00068. In mouse gastrocnemius muscle, constitutively activated FLJ00068 actually induced GLUT4 translocation to the sarcolemma. GLUT4 translocation by constitutively activated FLJ00068 was totally abolished in rac1 knockout mouse gastrocnemius muscle. Additionally, we were successful in detecting the activation of Rac1 following the expression of constitutively activated FLJ00068 in gastrocnemius muscle by immunofluorescence microscopy using an activation-specific probe. Collectively, these results strongly support the notion that FLJ00068 regulates Rac1 downstream of Akt2, leading to the stimulation of glucose uptake in skeletal muscle.

  10. Prostaglandin E1 joint plasma exchange treatment of chronic severe hepatitis%前列腺素E1联合血浆置换治疗慢性重型肝炎的临床研究

    Institute of Scientific and Technical Information of China (English)

    唐学兰

    2011-01-01

    目的 探讨前列腺素E1联合血浆置换治疗慢性重型肝炎的疗效.方法 将88例慢性重型肝炎患者完全随机分为治疗组与对照组.治疗组46例,在内科综合治疗的基础上予前列腺素E1联合血浆置换治疗;对照组42例,只予内科综合治疗.观察2组治疗前后的症状体征及相关实验室指标.结果 治疗组经治疗后症状体征均明显好转,总胆红素、ALT、总蛋白、白蛋白、胆碱酯酶、凝血酶原活动度、血氨均改善明显(P<0.01或P<0.05).治疗后,2组间除白蛋白水平外,其余各指标均差异有统计学意义(P<0.05).随访3个月,治疗组总有效率69.6%(32例)、早期有效率79.3%(23例)、中期有效率64.3%(9例),均明显高于对照组的47.6%(20例)、55.6%(15例)、38.5%(5例),差异均有统计学意义(均P<0.01).结论 前列腺素E1联合血浆置换治疗慢性重型肝炎能明显改善肝功能,明显提高疗效.%Objective To investigate the curative effect, timing and feasibility of prostaglandin E1 combined plasma exchange in treatment of chronic severe hepatitis. Methods Eighty-eight patients with chronic severe hepatitis were randomly divided into treatment group and control group. The treatment group was given prostaglandin E1 combined plasma exchange treatment based on the comprehensive treatment of internal medicine. Control group only had given the internal medicine comprehensive treatment. Results The symptoms and signs of the treatment group were improved after treatments, especially with total bilirubin, cholinesterase, prothrombin activity, NH3 ( P < 0.01,P < 0.05 ). After treatment, except for albumin, the others indicators of the two groups had significant difference ( P < 0.05). Follow-up for three months, the total effective rate of the treatment group was 69.6% ( 32cases ), early effective rate was 79.3% (23 cases), mid-term effective rate was 64.3% (9 cases) were all significantly higher than those of control group [47

  11. Transendothelial lipoprotein exchange and microalbuminuria

    DEFF Research Database (Denmark)

    Jensen, Jan Skov; Feldt-Rasmussen, Bo; Jensen, Kurt Svarre

    2004-01-01

    OBJECTIVE: Microalbuminuria associates with increased risk of atherosclerosis in individuals without diabetes. We hypothesized that transendothelial lipoprotein exchange is elevated among such individuals, possibly explaining increased intimal lipoprotein accumulation and thus atherosclerosis....... METHODS: Using an in vivo isotope technique, transendothelial exchange of low density lipoprotein (LDL) was measured in 77 non-diabetic individuals. Autologous 131-iodinated LDL was reinjected intravenously, and the 1-h fractional escape rate was calculated as index of transendothelial exchange. RESULTS...... transformed) plasma insulin: beta=0.6 (95% CI: 0.1-1.1); R=0.22; Plipoproteins, LDL size, body mass index, plasma volume, and use of medicine, and it was unlikely caused by altered hepatic LDL receptor expression...

  12. Hydrogen exchange

    DEFF Research Database (Denmark)

    Jensen, Pernille Foged; Rand, Kasper Dyrberg

    2016-01-01

    Hydrogen exchange (HX) monitored by mass spectrometry (MS) is a powerful analytical method for investigation of protein conformation and dynamics. HX-MS monitors isotopic exchange of hydrogen in protein backbone amides and thus serves as a sensitive method for probing protein conformation...... and dynamics along the entire protein backbone. This chapter describes the exchange of backbone amide hydrogen which is highly quenchable as it is strongly dependent on the pH and temperature. The HX rates of backbone amide hydrogen are sensitive and very useful probes of protein conformation......, as they are distributed along the polypeptide backbone and form the fundamental hydrogen-bonding networks of basic secondary structure. The effect of pressure on HX in unstructured polypeptides (poly-dl-lysine and oxidatively unfolded ribonuclease A) and native folded proteins (lysozyme and ribonuclease A) was evaluated...

  13. Development and validation of a solid-phase extraction method using anion exchange sorbent for the analysis of cannabinoids in plasma and serum by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Gasse, Angela; Pfeiffer, Heidi; Köhler, Helga; Schürenkamp, Jennifer

    2016-07-01

    The aim of this work was to develop and validate a solid-phase extraction (SPE) method for the analysis of cannabinoids with emphasis on a very extensive and effective matrix reduction in order to ensure constant good results in selectivity and sensitivity regardless of the applied measuring technology. This was obtained by the use of an anion exchange sorbent (AXS) and the purposive ionic interaction between matrix components and this sorbent material. In a first step, the neutral cannabinoids ∆9-tetrahydrocannabinol (THC) and 11-hydroxy-∆9-tetrahydrocannabinol (11-OH-THC) were eluted, leaving 11-nor-9-carboxy-∆9-tetrahydrocannabinol (THC-COOH) and the main interfering matrix components bound to the AXS. In a second step, exploiting differences in pH and polarity, it was possible to separate matrix components and THC-COOH, thereby yielding a clean elution of THC-COOH into the same collecting tube as THC and 11-OH-THC. Even when using a simple measuring technology like gas chromatography with single quadrupole mass spectrometry, this two-step elution allows for an obvious decrease in number and intensity of matrix interference in the chromatogram. Hence, in both plasma and serum, the AXS extracts resulted in very good selectivity. Limits of detection and limits of quantification were below 0.25 and 0.35 ng/mL for the neutral cannabinoids in both matrices, 2.0 and 3.0 ng/mL in plasma and 1.6 and 3.3 ng/mL in serum for THC-COOH. The recoveries were ≥79.8 % for all analytes. Interday and intraday imprecisions ranged from 0.8 to 6.1 % relative standard deviation, and accuracy bias ranged from -12.6 to 3.6 %.

  14. Development and validation of a UHPLC-MS/MS assay for colistin methanesulphonate (CMS) and colistin in human plasma and urine using weak-cation exchange solid-phase extraction.

    Science.gov (United States)

    Zhao, Miao; Wu, Xiao-Jie; Fan, Ya-Xin; Guo, Bei-Ning; Zhang, Jing

    2016-05-30

    A rapid ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay method was developed for determination of CMS and formed colistin in human plasma and urine. After extraction on a 96-well SPE Supra-Clean Weak Cation Exchange (WCX) plate, the eluents were mixed and injected into the UHPLC-MS/MS system directly. A Phonomenex Kinetex XB-C18 analytical column was employed with a mobile phase consisting of solution "A" (acetonitrile:methanol, 1:1, v/v) and solution "B" (0.1% formic acid in water, v/v). The flow rate was 0.4 mL/min with gradient elution over 3.5 min. Ions were detected in ESI positive ion mode and the precursor-product ion pairs were m/z 390.7/101.3 for colistin A, m/z 386.0/101.2 for colistin B, and m/z 402.3/101.2 for polymyxin B1 (IS), respectively. The lower limit of quantification (LLOQ) was 0.0130 and 0.0251 mg/L for colistin A and colistin B in both plasma and urine with accuracy (relative error, %) <± 12.6% and precision (relative standard deviation, %) <± 10.8%. Stability of CMS was demonstrated in biological samples before and during sample treatment, and in the extract. This new analytical method provides high-throughput treatment and optimized quantification of CMS and colistin, which offers a highly efficient tool for the analysis of a large number of clinical samples as well as routine therapeutic drug monitoring.

  15. A rapid and precise method for measuring plasma apoE-rich HDL using polyethylene glycol and cation-exchange chromatography: a pilot study on the clinical significance of apoE-rich HDL measurements.

    Science.gov (United States)

    Ikeda, Toru; Shinohata, Ryoko; Murakami, Masaaki; Hina, Kazuyoshi; Kamikawa, Shigeshi; Hirohata, Satoshi; Kusachi, Shozo; Tamura, Arisa; Usui, Shinichi

    2017-02-01

    High-density lipoprotein (HDL) containing apolipoprotein E (apoE-rich HDL) represents only a small portion of plasma HDL. Reliable methods for determining and isolating apoE-rich HDL have not been well studied. We established a novel analytical method for apoE-rich HDL using polyethylene glycol and a cation-exchange column (PEG-column method). Furthermore, we examined biochemical correlates of apoE-rich HDL-cholesterol (HDL-C) in 36 patients who underwent coronary computed tomographic angiography. Our PEG-column method demonstrated high reproducibility (coefficient of variation HDL-C concentrations. Isolated apoE-rich HDL exhibited a larger diameter (14.8nm) than apoE-poor HDL (10.8nm) and contained both apoE and apoA-I. ApoE-rich HDL-C concentrations correlated significantly with triglycerides (rs=-0.646), LDL size (rs=0.472), adiponectin (rs=0.476), and other lipoprotein components. No significant correlation was obtained with the coronary calcium score. Multiple regression analysis revealed that plasma triglycerides and adiponectin concentrations remained significant independent predictors of apoE-rich (adjusted R(2)=0.486) but not apoE-poor HDL-C. The PEG-column method demonstrated, to various degrees, significant correlations between HDL subfractions and several lipid-related biomarkers involved in an atherogenic lipoprotein profile. Our separation technique for apoE-rich HDL is useful to clarify the role of apoE-rich HDL in atherosclerosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Exchange Options

    NARCIS (Netherlands)

    Jamshidian, Farshid

    2007-01-01

    The contract is described and market examples given. Essential theoretical developments are introduced and cited chronologically. The principles and techniques of hedging and unique pricing are illustrated for the two simplest nontrivial examples: the classical Black-Scholes/Merton/Margrabe exchange

  17. International Exchanges

    Institute of Scientific and Technical Information of China (English)

    2014-01-01

    <正>On April 1st,2014,CPAPD Deputy Secretary General Ms.Chen Huaifan met with Mr.Djudjuk Juyoto Suntani,President of the World Peace Committee,Indonesia,who headed the delegation,in the CPAPD office.The two sides exchanged views on issues of common concern including cooperation between the two organizations and the inheritance of Chinese culture.

  18. Exchange Options

    NARCIS (Netherlands)

    Jamshidian, F.

    2007-01-01

    The contract is described and market examples given. Essential theoretical developments are introduced and cited chronologically. The principles and techniques of hedging and unique pricing are illustrated for the two simplest nontrivial examples: the classical Black-Scholes/Merton/Margrabe exchange

  19. Investigation on the method and safety of the non - heparinized plasma exchange therapy in treating patients with hepatic failure%无肝素血浆置换治疗肝功能衰竭的方法及安全性探讨

    Institute of Scientific and Technical Information of China (English)

    张文华; 贾文玲; 周子英; 唐海涛; 王凤梅

    2012-01-01

    Objective To explore the method and safely of the non - heparinized plasma exchange in treating patients with hepatic failure. Methods Plasma exchange therapy was used to treat 62 patients with hepatic failure and these patients were randomly divided into 2 groups: 30 patients as the treatment group and 32 patients as the control group. Patients in the treatment group were treated with non - hepa-rinized plasma exchange therapy by using physiological saline to wash the plasma separator continuously during the recovery period , giving 81 times plasma exchange treatment in total. Patients in the control group were treated with heparinized plasma exchange therapy, they were given 82 times plasma exchange treatment in total. Results There were no adverse effects related to haemorrhage and blood coagulation in the treatment group, whereas other types of adverse effects occurred in 23 patients of the same group. On the other hand there were 12 adverse effects related to haemorrhage and blood coagulation in the control group plus other adverse effects occurred in 26 patients of this group. The incidence rate of adverse effects related to haemorrhage and blood coagulation between the two groups has significant difference(P 0. 05) Conclusion Using the non - heparinized plasma exchange to treat patients with hepatic failure is safe and the incidence rate of adverse effects related to haemorrhage and blood coagulation is lower whereas the incidence rate of other adverse effects is similar to the traditional.plasma exchange therapy. This therapy is characterized by simplicity in operation and high safety level.%目的 探讨采用无肝素血浆置换治疗肝衰竭患者的方法及安全性.方法 采用血浆置换对62例肝衰竭患者进行治疗,随机分为两组,治疗组30例进行无肝素血浆置换治疗,治疗过程中持续给予生理盐水冲洗分离器及管路,共81人次.对照组32例常规加用肝素进行血浆置换治疗,共82人次,观察治疗中

  20. 血浆置换治疗儿童危重自身免疫性疾病临床分析%Plasma exchange in the treatment of pediatric antoimmune diseases

    Institute of Scientific and Technical Information of China (English)

    陈慧; 封志纯; 王斌; 陶少华; 常平

    2008-01-01

    Objective To investigate the efficacy of plasma exchange (PE) and to explore its mechanism in the treatment of pediatric antoimmune diseases.Methods The 12 children with antoimmune diseases,including 3 systemic lupus erythematosus (SLE),3 thrombotic thrombocytopenic purpura (TTP),5 Guillain-Barre syndrome (GBS),1 hemolytic uremic syndrome(HUS),weighted 10~35 kg,were treated with PE.The PE volume was 50~70 ml/kg(1/4 Hydroxyethyl Starch,3/4 fresh frozen plasma)every time.The ANA,anti-dsDNA,complements and clinic symptoms were examined before and after PE.Results The neurological and psychiatric symptoms in 2 SLE childrern were ameliorated after the first PE.The levels of complement were increased,while the levels of ANA and anti-dsDNA were decreased after PE.The clinical symptoms of the 3 TTP were resolved immediately after the therapy,and their thrombocyte returned to normal in the fifth day after PE.The 4 GBS had not acute respiratory failure.Myodynamia of the lower limbs had improved increasedly after PE.Two children in 12 patiens died of pulmonary hemorrhage,10 had been discharged from the hospital,the cure rate was 83%.Conclusion PE was effective in treatment of pediatric antoimmune diseases and improved survival rate of patients.%目的 观察血浆置换(plasma exchange,PE)技术对儿童危重自身免疫性疾病的疗效并探讨其机制.方法 用PE治疗3例系统性红斑狼疮,3例血栓性血小板减少性紫癜,5例吉兰-巴雷综合征,1例溶血尿毒综合征患儿.12例危重自身免疫性疾病患儿体重10~35 kg,平均(26.25±6.85) kg,每次置换量50~70 ml/kg,每日或隔日1次,共置换3~5次.检测PE治疗前后血生化、自身抗体及临床症状、体征等变化.结果 2例系统性红斑狼疮患儿在第1次PE治疗后神经系统症状明显减轻,血清补体升高,ANA和抗ds-DNA抗体滴度下降;3例血栓性血小板减少性紫癜患儿神志改善,于PE治疗后第5天血小板恢复正常;4

  1. Ion exchange equilibrium constants

    CERN Document Server

    Marcus, Y

    2013-01-01

    Ion Exchange Equilibrium Constants focuses on the test-compilation of equilibrium constants for ion exchange reactions. The book first underscores the scope of the compilation, equilibrium constants, symbols used, and arrangement of the table. The manuscript then presents the table of equilibrium constants, including polystyrene sulfonate cation exchanger, polyacrylate cation exchanger, polymethacrylate cation exchanger, polysterene phosphate cation exchanger, and zirconium phosphate cation exchanger. The text highlights zirconium oxide anion exchanger, zeolite type 13Y cation exchanger, and

  2. Experimental study on the influence of charge exchange on the stopping power in the interaction of chlorine with a gas and a deuterium plasma; Etude experimentale de l`influence des echanges de charges sur le pouvoir d`arret dans l`interaction d`ions chlore avec un gaz et un plasma de deuterium

    Energy Technology Data Exchange (ETDEWEB)

    Nectoux, Marie [Inst. de Physique Nucleaire, Paris-11 Univ., 91 - Orsay (France)

    1998-01-06

    This thesis is placed in the context of the physics of energy deposition of a multicharged heavy ion beam in matter at intermediate energies. The experiment gave measurements of energy loss as a function of final charge state for chlorine ions at 1.7 MeV/u in deuterium gas or plasma. In this way, we explore the influence of charge state evolution, depending on experimentally measured capture and ionization cross sections and the electron density of the target, on energy loss. The target is cylindrical and enclosed by two fast valves. The plasma is created in the gas by a discharge, which induces a magnetic perturbation of the beam (lens effect). This effect induces a divergent and misaligned outgoing beam. A simulation including charge state and velocity evolution of the projectile in flight in the magnetic field has been made in order to optimize beam analysis, to reach a precision better than 10{sup -3} in energy measurement. This study led to removal of the target to the `Split Pole`, a refocusing magnetic spectrometer. The first results obtained clearly show the dependence of energy loss on exit charge and especially on its evolution in the target. This is explained in terms of the lengths covered by the projectile in its successive charge states in the target, which depends on target electron density and the medium considered. In plasma, we observed an energy distribution with exit charge twice that observed in gas, because of a strong decrease of charge exchange. A comparison of data obtained in gas with stopping power calculated from Bethe-Bloch-Barkas theory leads to the necessity of including spatial extension of the projectile charge in the theory. (author) 81 refs., 62 figs., 5tabs.

  3. Value of plasma exchange in the treatment of patients with severe liver disease in pregnancy%血浆置换在妊娠期重症肝病患者治疗中的应用价值

    Institute of Scientific and Technical Information of China (English)

    魏绪霞; 熊亮; 陆平兰; 易小猛; 吕海金; 刘剑戎; 李敏如; 安玉玲; 易慧敏

    2014-01-01

    目的:探讨血浆置换在妊娠期重症肝病患者治疗中的作用及安全性。方法回顾性分析2009年3月至2013年11月在中山大学附属第三医院外科ICU接受诊治的28例妊娠期重症肝病患者临床资料。根据患者治疗方案分为治疗组与对照组,其中治疗组12例,年龄21~28岁,中位年龄25岁;对照组16例,年龄18~29岁,中位年龄24岁。所有患者均签署知情同意书,符合医学伦理学规定。入组患者均分娩后转入外科ICU,予以抗感染、抗病毒、护肝、利胆、补充人血白蛋白和丙种球蛋白、输注凝血物质等治疗。治疗组在上述治疗的基础上予以新鲜同型血浆置换治疗。比较两组临床检验指标和临床疗效,观察治疗组血浆置换后的不良反应情况。两组患者检验指标比较采用t检验,率的比较采用χ2检验。结果治疗组患者治疗后血TB、ALB、Scr、空腹血糖(FPG)、凝血酶原活动度(PTA)和动脉血乳酸(Lac)分别为(197±69)μmol/L、(30±7)g/L、(111±42)μmol/L、(5.7±2.4)mmol/L、(55±24)%、(2.3±0.6)mmol/L,对照组相应为(299±113)μmol/L、(24±6)g/L、(165±82)μmol/L、(3.7±1.7)mmol/L、(33±11)%(、4.4±1.5)mmol/L,治疗组较对照组明显改善(t=-3.453,2.389,-4.892,2.798,6.079,-3.339;P<0.05)。治疗组有效率为92%(11/12),明显高于对照组的56%(9/16)(χ2=4.215,P<0.05)。治疗组患者中1例输注血浆后出现一过性低血压,予小剂量血管活性药物调控,1h后血压恢复正常。结论血浆置换能改善妊娠期重症肝病患者的临床检验指标,提高临床疗效,是一种安全、有效的治疗方法。%Objective To investigate the therapeutic effect and safety of plasma exchange in the treatment of patients with severe liver disease in pregnancy. Methods Clinical data of 28 patients with severe liver disease in pregnancy in

  4. Púrpura trombocitopênica trombótica - remissão completa em paciente com mau prognóstico após tratamento com plasmaférese terapêutica e rituximabe Successful outcome in poor-prognostic acute thrombotic thrombocytopenic purpura treated with plasma exchange and rituximab

    Directory of Open Access Journals (Sweden)

    Cesar de Almeida Neto

    2008-02-01

    Full Text Available A púrpura trombocitopênica trombótica (PTT é uma doença rara e fatal que deve ser diagnosticada e tratada prontamente a fim de se obter melhor resposta terapêutica. Apresentamos um caso de PTT aguda grave tratada com plasmaférese e rituximabe. Ao diagnóstico, a paciente apresentava anemia hemolítica microangiopática, icterícia, febre, convulsões, seguidas por coma e choque hipovolêmico. Os exames laboratoriais iniciais mostravam DHL=2.860 IU/L, contagem de plaquetas de 37 x 10(9/L, hemoglobina de 5,1 g/dL e no esfregaço de sangue periférico havia a presença de esquizócitos. Iniciado tratamento para PTT com pulsoterapia com metilprednisolona e plasmaféreses terapêuticas diárias com troca de uma volemia plasmática e substituição com plasma fresco congelado. Após cinco sessões de plasmaférese, houve piora no quadro neurológico, acompanhado por aumento importante de DHL, ALT, AST e a contagem de plaquetas era de 72 x 10(9/L. Iniciamos o uso de rituximabe na dose padrão de 375mg/m²/semana/4 semanas e passamos a utilizar plasma pobre em crioprecipitado como reposição durante as plasmaféreses. Dois dias após a mudança na conduta terapêutica, houve importante melhora do quadro neurológico, estabilização da contagem de plaquetas e queda acentuada de DHL. Após 23 procedimentos de plasmaférese e quatro doses de rituximabe, a paciente apresentou remissão completa, mantida há 34 meses. A plasmaférese terapêutica com plasma pobre em crioprecipitado e o uso concomitante de rituximabe foi uma estratégia útil no tratamento deste caso de PTT aguda grave. Porém, ensaios clínicos prospectivos e randomizados são necessários para confirmar estes achados.Thrombotic thrombocytopenic purpura (TTP is a rare severe disease that must be diagnosed and treated promptly for a successful outcome. We report a case of severe acute TTP treated with plasma exchange and rituximab. The patient presented at diagnosis with severe

  5. International Exchanges

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    On October 12,2015,Mr.Zhu Rui,CPAPD Secretary General,chaired informal discussions with U.S.young experts and scholars on arms control and non-proliferation.The two sides exchanged views on international arms control,disarmament,non-proliferation and nuclear security,etc.During October 12 to 16,2015,at the invitation of the CPAPD,a four-member delegation from the Vietnam Peace Committee headed by its Vice-President Ms.Nguyen Thi Hoang Van

  6. 血浆置换在儿科的应用:附93例病例分析%Plasma exchange in pediatric patients:analysis of 93 cases

    Institute of Scientific and Technical Information of China (English)

    张桂菊; 刘小荣; 孟繁英; 马军梅

    2015-01-01

    Objective To assess the indications,effect and complications of plasma exchange(PE) application in children.Methods A total of 93 patients treated with PE were enrolled,and the clinical mani-festations before and after treatment were analyzed retrospectively.Results Ninety-three cases of children received PE treatment 2 to 1 1 times,an average of 5.5 times,53 cases with combination blood purification treatment.In 93 patients,there were 36 cases with hemolytic uremic syndrome,among them,22 cases (61.1 %)were healed,14 cases(38.9%)remained hematuria,and proteinuria and 5 of them(13.9%)with injured renal function.There were 9 cases with Guillain-Barre'syndrome and 8 of them got improved.Six in 8 cases with anti-N-methyl-D-aspartate receptorencephalitis got better after treatment.All of the 3 cases with myasthenia gravis got recovery.There were 4 cases with acute disseminated encephalomyelitis and 4 cases with chronic inflammatory demyelinating polyneuropathy respectively.The treatment effect rate was all 3 /4. Four in 9 patients with poisonous mushroom poisoning also got improved.The adverse reactions were ob-served in 12 cases(12.9%),including allergic in 9 cases and hypotension in 3 patients.No serious adverse reactions were found during treatment.Conclusion PE is an safe and effective blood purification method, with less adverse reaction,for treatment of the atypical hemolytic uremic syndrome and some serious nervous system diseases,such as myasthenia gravis,Guillain-Barre syndrome,etc.%目的:探讨血浆置换(plasma exchange,PE )在儿科应用的指征、治疗效果及不良反应。方法回顾性分析93例应用 PE 治疗患儿,总结前后病情转归。结果93例患儿 PE 治疗2~11次,平均5.5次,53例患儿采用联合血液净化治疗。溶血尿毒综合征36例,22例(61.1%)痊愈,14例(38.9%)遗留不同程度血尿、蛋白尿,其中5例(13.9%)肾功能未恢复正常。神经系统疾病患儿中吉兰-巴雷综合征9例,治疗后好转8

  7. Umbilical Cord-Derived Mesenchymal Stem Cell Transplantation in Hepatitis B Virus Related Acute-on-Chronic Liver Failure Treated with Plasma Exchange and Entecavir: a 24-Month Prospective Study.

    Science.gov (United States)

    Li, Yu-Hua; Xu, Ying; Wu, Hua-Mei; Yang, Jing; Yang, Li-Hong; Yue-Meng, Wan

    2016-12-01

    Search for an effective therapy for patients with hepatitis B virus related acute-on-chronic liver failure (HBV-ACLF) remains an important issue. This study investigated the efficacy of umbilical cord-derived mesenchymal stem cell (UC-MSC) transplantation in patients with HBV-ACLF. 45 consecutive entecavir-treated HBV-ACLF patients were prospectively studied. Among these patients, 11 received both plasma exchange (PE) and a single transplantation of UC-MSCs (group A), while 34 received only PE (group B). The primary endpoint was survival at 24 months. Compared with group B, levels of albumin, alanine aminotransferase, aspartate aminotransferase, total bilirubin, direct bilirubin, prothrombin time (PT), international normalized ratio (INR) and model for end-stage liver disease score in group A improved significantly at 4 weeks after transplantation (p < 0.05). Levels of albumin, PT and INR in group A were also markedly improved at 24 months (p < 0.05). Group A had significantly higher cumulative survival rate at 24 months (54.5 % v.s. 26.5 %, p = 0.015 by log rank test). Between the two groups, levels of creatinine, White blood cell, hemoglobin and platelet were similar. HBeAg loss and hepatocellular carcinoma incidence were similar at 24 months. Group assignment (relative risk: 2.926, 95%confidence interval: 1.043-8.203, p = 0.041) was an independent predictor for survival at 24 months. Success rate of UC-MSC transplantation was 100 % in group A. No severe adverse event was observed in any patient. UC-MSC transplantation is safe and effective for HBV-ACLF patients treated with PE and entecavir. It further improves the hepatic function and survival.

  8. Genetic interactions between the Golgi Ca2+/H+ exchanger Gdt1 and the plasma membrane calcium channel Cch1/Mid1 in the regulation of calcium homeostasis, stress response and virulence in Candida albicans.

    Science.gov (United States)

    Wang, Yanan; Wang, Junjun; Cheng, Jianqing; Xu, Dayong; Jiang, Linghuo

    2015-11-01

    The Golgi-localized Saccharomyces cerevisiae ScGdt1 is a member of the cation/Ca(2+) exchanger superfamily. We show here that Candida albicans CaGdt1 is the functional homolog of ScGdt1 in calcium sensitivity, and shows genetic interactions with CaCch1 or CaMid1 in response to ER stresses. In addition, similar to ScCCH1 and ScMID1, deletion of either CaCCH1 or CaMID1 leads to a growth sensitivity of cells to cold stress, which can be suppressed by deletion of CaGDT1. Furthermore, deletion of CaCCH1 leads to a severe delay in filamentation of C. albicans cells, and this defect is abolished by deletion of CaGDT1. In contrast, CaGDT1 does not show genetic interaction with CaMID1 in filamentation. Interestingly, C. albicans cells lacking both CaMID1 and CaGDT1 exhibit an intermediate virulence between C. albicans cells lacking CaCCH1 (non-virulent) and C. albicans cells lacking CaGDT1 (partially virulent), while C. albicans cells lacking both CaCCH1 and CaGDT1 are not virulent in a mouse model of systemic candidiasis. Therefore, CaGdt1 genetically interacts with the plasma membrane calcium channel, CaCch1/CaMid1, in the response of C. albicans cells to cold and ER stresses and antifungal drug challenge as well as in filamentation and virulence.

  9. Optimization of collision/reaction gases for determination of 90Sr in atmospheric particulate matter by inductively coupled plasma tandem mass spectrometry after direct introduction of air via a gas-exchange device

    Science.gov (United States)

    Suzuki, Yoshinari; Ohara, Ryota; Matsunaga, Kirara

    2017-09-01

    Nuclear power plant accidents release radioactive strontium 90 (90Sr) into the environment. Monitoring of 90Sr, although important, is difficult and time consuming because it emits only beta radiation. We have developed a new analytical system that enables real-time analysis of 90Sr in atmospheric particulate matter with an analytical run time of only 10 min. Briefly, after passage of an air sample through an impactor, a small fraction of the sample is introduced into a gas-exchange device, where the air is replaced by Ar. Then the sample is directly introduced into an inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) system equipped with a collision/reaction cell to eliminate isobaric interferences on 90Sr from 90Zr+, 89Y1H+, and 90Y+. Experiments with various reaction gas conditions revealed that these interferences could be minimized under the following optimized conditions: 1.0 mL min- 1 O2, 10.0 mL min- 1 H2, and 1.0 mL min- 1 NH3. The estimated background equivalent concentration and estimated detection limit of the system were 9.7 × 10- 4 and 3.6 × 10- 4 ng m- 3, respectively, which are equivalent to 4.9 × 10- 6 and 1.8 × 10- 6 Bq cm- 3. Recoveries of Sr in PM2.5 measured by real-time analysis compared to those obtained by simultaneously collection on filter was 53 ± 23%, and using this recovery, the detection limit as PM2.5 was estimated to be 3.4 ± 1.5 × 10- 6 Bq cm- 3. That is, this system enabled detection of 90Sr at concentrations < 5 × 10- 6 Bq cm- 3 even considering the insufficient fusion/vaporization/ionization efficiency of Sr in PM2.5.

  10. Clinical efficacy of plasma exchange method in the treatment of autoimmune disease%血浆置换法治疗自身免疫性疾病的效果

    Institute of Scientific and Technical Information of China (English)

    冉崇丕

    2015-01-01

    Objective To study the clinical efficacy of Plasma exchange method in the treatment of autoimmune dis-ease. Methods From March 2011 to March 2014 in the PeoPle's HosPital of Dangyang City,a total of 40 autoimmune diseases Patients were selected,4 cases of scleroderma,5 cases of systemic luPus erythematosus,18 cases of rheumatoid arthritis,7 ca-ses of Polymyositis/dermatomyositis,6 cases of mixed connected tissue,Patients were all treated with Plasma exchange meth-od. ComPlement C3 ,comPlement C4 ,IgG,IgA,IgM,erythrocyte sedimentation rate( ESR),C-reactive Protein( CRP), rheumatoid factors( RF),creatine kinase( CK),lactic dehydrogenase( LDH),Platelet count( PLT),hemoglobin( Hb), hydroxybutyrate hehydrogenase(HBDH)before and after treatment were comPared. Results ComPlement C3,comPlement C4 ,IgG,IgA,IgM of Patients before and after treatment were comPared,the differences were statistically significant( P﹤0. 05). After treatment RF,CRP,ESR levels of rheumatoid arthritis Patients were lower than those before treatment,the differences were statistically significant( P﹤0. 05). Before and after treatment ESR,CRP levels of scleroderma Patients were comPared,the differences were statistically significant(P﹤0. 05);before and after treatment RBC,WBC,PLT,Hb were showed no significant differences(P﹥0. 05). Before and after treatment ESR,CRP levels of systemic luPus erythematosus Pa-tients were comPared,the differences were statistically significant( P﹤0. 05);before and after treatment RBC,WBC,PLT, Hb were showed no significant differences(P﹥0. 05). Before and after treatment LDH,HBDH,ESR,CK of Polymyositis/dermatomyositis Patients were comPared,the differences were statistically significant( P﹤0. 05). Conclusion The effect of Plasma exchange is significant in the treatment of autoimmune diseases,and the adverse reactions are less.%目的:探讨血浆置换法治疗自身免疫性疾病的临床效果。方法选取2011年3月—2014年3月当阳市人民医院

  11. Energy exchanges in reconnection outflows

    Science.gov (United States)

    Lapenta, Giovanni; Goldman, Martin V.; Newman, David L.; Markidis, Stefano

    2017-01-01

    Reconnection outflows are highly energetic directed flows that interact with the ambient plasma or with flows from other reconnection regions. Under these conditions the flow becomes highly unstable and chaotic, as any flow jets interacting with a medium. We report here massively parallel simulations of the two cases of interaction between outflow jets and between a single outflow with an ambient plasma. We find in both case the development of a chaotic magnetic field, subject to secondary reconnection events that further complicate the topology of the field lines. The focus of the present analysis is on the energy balance. We compute each energy channel (electromagnetic, bulk, thermal, for each species) and find where the most energy is exchanged and in what form. The main finding is that the largest energy exchange is not at the reconnection site proper but in the regions where the outflowing jets are destabilized.

  12. [Therapeutic plasma exchange: applications in neurology].

    Science.gov (United States)

    Láinez-Andrés, José M; Gascón-Giménez, Francisco; Coret-Ferrer, Francisco; Casanova-Estruch, Bonaventura; Santonja, José M

    2015-02-01

    Introduccion. El recambio plasmatico es una tecnica utilizada en el tratamiento de algunas enfermedades neurologicas de base autoinmune desde los años ochenta, especialmente en situaciones agudas. En los ultimos años se han publicado nuevos datos sobre su empleo en numerosas entidades con base autoinmune, ampliando, con ello, el espectro de utilizacion. Objetivo. Actualizar las indicaciones de esta tecnica en el tratamiento de las enfermedades neurologicas. Desarrollo. Se ha realizado una revision exhaustiva de todos los articulos publicados desde los años ochenta sobre la eficacia del recambio plasmatico en el tratamiento de las diferentes enfermedades neurologicas. Tambien se ha efectuado un analisis detallado de las recomendaciones y evidencias de la utilizacion de este procedimiento por parte de las diferentes sociedades cientificas. Conclusiones. El recambio plasmatico ha demostrado ser una alternativa eficaz con evidencia cientifica de primer nivel en enfermedades como el sindrome de Guillain-Barre, la polineuropatia desmielinizante inflamatoria cronica o la miastenia grave. Ha mostrado ser eficaz en el tratamiento de episodios desmielinizantes agudos sin respuesta a otras terapias, en los brotes de neuromielitis optica y en otras enfermedades del sistema nervioso central producidas por anticuerpos. En los estudios comparativos con inmunoglobulinas intravenosas, la eficacia de ambas terapias es similar. Es preciso seguir realizando estudios comparativos para conocer mejor los mecanismos y establecer indicaciones prioritarias y comparar la relacion coste-eficacia de ambos procedimientos.

  13. Segmented heat exchanger

    Science.gov (United States)

    Baldwin, Darryl Dean; Willi, Martin Leo; Fiveland, Scott Byron; Timmons, Kristine Ann

    2010-12-14

    A segmented heat exchanger system for transferring heat energy from an exhaust fluid to a working fluid. The heat exchanger system may include a first heat exchanger for receiving incoming working fluid and the exhaust fluid. The working fluid and exhaust fluid may travel through at least a portion of the first heat exchanger in a parallel flow configuration. In addition, the heat exchanger system may include a second heat exchanger for receiving working fluid from the first heat exchanger and exhaust fluid from a third heat exchanger. The working fluid and exhaust fluid may travel through at least a portion of the second heat exchanger in a counter flow configuration. Furthermore, the heat exchanger system may include a third heat exchanger for receiving working fluid from the second heat exchanger and exhaust fluid from the first heat exchanger. The working fluid and exhaust fluid may travel through at least a portion of the third heat exchanger in a parallel flow configuration.

  14. Stirring Unmagnetized Plasma

    CERN Document Server

    Collins, C; Wallace, J; Jara-Almonte, J; Reese, I; Zweibel, E; Forest, C B; 10.1103/PhysRevLett.108.115001

    2012-01-01

    A new concept for spinning unmagnetized plasma is demonstrated experimentally. Plasma is confined by an axisymmetric multi-cusp magnetic field and biased cathodes are used to drive currents and impart a torque in the magnetized edge. Measurements show that flow viscously couples momentum from the magnetized edge (where the plasma viscosity is small) into the unmagnetized core (where the viscosity is large) and that the core rotates as a solid body. To be effective, collisional viscosity must overcome the ion-neutral drag due to charge exchange collisions.

  15. Jeans instability with exchange effects in quantum dusty magnetoplasmas

    Energy Technology Data Exchange (ETDEWEB)

    Jamil, M., E-mail: jamil.gcu@gmail.com [Department of Physics, COMSATS Institute of Information Technology, Lahore 54000 (Pakistan); Rasheed, A. [Department of Physics, Government College University, Faisalabad 38000 (Pakistan); Rozina, Ch. [Department of Physics, Lahore College for Women University, Lahore 54000 (Pakistan); Jung, Y.-D. [Department of Applied Physics and Department of Bionanotechnology, Hanyang University, Ansan, Kyunggi-Do 426-791 (Korea, Republic of); Salimullah, M. [Department of Physics, Jahangirnagar University, Savar, Dhaka 1342 (Bangladesh)

    2015-08-15

    Jeans instability is examined in magnetized quantum dusty plasmas using the quantum hydrodynamic model. The quantum effects are considered via exchange-correlation potential, recoil effect, and Fermi degenerate pressure, in addition to thermal effects of plasma species. It is found that the electron exchange and correlation potential have significant effects over the threshold value of wave vector and Jeans instability. The presence of electron exchange and correlation effect shortens the time of dust sound that comparatively stabilizes the self gravitational collapse. The results at quantum scale are helpful in understanding the collapse of the self-gravitating dusty plasma systems.

  16. Safety of plasma exchange therapy in patients with anti-NMDA receptor encephalitis%血浆置换治疗抗N-甲基-M-天冬氨酸受体脑炎的安全性分析

    Institute of Scientific and Technical Information of China (English)

    张艳; 高岱佺; 叶红; 宿英英

    2015-01-01

    目的 探讨血浆置换(PE)治疗抗N-甲基-M-天冬氨酸(NMDA)受体脑炎的安全性和可操作性.方法 前瞻性观察研究2012年1月至2015年1月收入宣武医院神经内科监护病房的抗NMDA受体脑炎患者PE治疗的不良反应和疗效.结果 共纳入9例患者接受PE治疗54次,全部(100%)患者经过PE治疗后CSF和(或)血清中NMDA受体抗体滴度均有减低或转为阴性,共5例(55.5%)患者临床好转.PE不良反应依次为:不自主运动增加、低血压、PE管路凝血、体温升高、过敏反应和深静脉置管处管口周围渗血.无致死的严重不良反应.结论 PE可有效治疗抗NMDA受体脑炎,并且安全可行.%Objective To explore the safety of plasma exchange (PE) therapy in patients with anti-NMDA receptor encephalitis.Methods Prospective reviews were conducted for the adverse events and therapeutic efficacies of PE therapy in 9 patients with anti-NMDA receptor encephalitis admitted into neurointensive care unit from January 2012 to January 2015.Results A total of 54 PE procedures were performed.The NMDA receptor antibody titer of cerebrospinal fluid (CSF) and/or sera in 9 patients (100%) decreased or turned negative.Five patients (55.5%) demonstrated clinical improvement after PE therapy.And clinical complications included frequent involuntary movements,hypotension,coagulation of PE channel,febricity,allergic response and errhysis around peripheral venous access.Conclusion PE is effective,safe and well-tolerated in patients with anti-NMDA receptor encephalitis.

  17. Handbook on heat exchangers

    Science.gov (United States)

    Bazhan, Pavel I.; Kanevets, Georgii E.; Seliverstov, Vladimir M.

    Essential data on heat exchange equipment used in ship, locomotive, automotive, and aircraft powerplants are presented in a systematic manner. The data cover the principal types and technical and performance characteristics of heat exchangers, fundamentals of the theory of heat exchange, calculation of heat transfer coefficients for different types of heat exchange apparatus, optimization of heat exchangers, computer-aided design of heat exchange equipment, testing techniques, and test result processing.

  18. Totalization Data Exchange (TDEX)

    Data.gov (United States)

    Social Security Administration — The Totalization Data Exchange (TDEX) process is an exchange between SSA and its foreign country partners to identify deaths of beneficiaries residing abroad. The...

  19. Exchange frequency in replica exchange molecular dynamics

    Science.gov (United States)

    Sindhikara, Daniel; Meng, Yilin; Roitberg, Adrian E.

    2008-01-01

    The effect of the exchange-attempt frequency on sampling efficiency is studied in replica exchange molecular dynamics (REMD). We show that sampling efficiency increases with increasing exchange-attempt frequency. This conclusion is contrary to a commonly expressed view in REMD. Five peptides (1-21 residues long) are studied with a spectrum of exchange-attempt rates. Convergence rates are gauged by comparing ensemble properties between fixed length test REMD simulations and longer reference simulations. To show the fundamental correlation between exchange frequency and convergence time, a simple model is designed and studied, displaying the same basic behavior of much more complex systems.

  20. 血浆置换治疗以肝脏损害为突出表现的儿童鱼胆中毒%Application of plasma exchange therapy to treat fish bile poisoning in children with hepatic damage

    Institute of Scientific and Technical Information of China (English)

    陈光明; 陈秀丽; 王承峰; 李媛媛; 陈丽; 翁增凤; 陈锦华; 詹海霞

    2016-01-01

    目的:探讨血浆置换(PE)治疗儿童鱼胆中毒的疗效及安全性。方法11例以肝脏损害为突出表现的鱼胆中毒儿童,在常规对症治疗的基础上,于入院后2~20 h后给予PE治疗;观察PE治疗前后临床症状及生命体征变化,并于PE前、PE后、PE后3 d、PE后7 d抽取静脉血监测血生化改变。结果11例患儿经PE治疗后临床症状很快消失;PE治疗过程中患儿平均动脉压(MAP)、心率(HR)、呼吸频率(RR)和脉搏血氧饱和度(SpO2)等生命体征持续稳定;PE治疗前后各时间点丙氨酸转氨酶(ALT)、天冬氨酸转氨酶(AST)、总胆红素(TB)、直接胆红素(DB)、血尿素氮(BUN)、血肌酐(SCR)、肌酸磷酸激酶(CK)、心肌型肌酸激酶同功酶(CK-MB)、乳酸脱氢酶(LDH)、α-羟丁酸脱氢酶(HBD)值存在统计学差异(P<0.05);结论 PE治疗儿童鱼胆中毒安全有效,早期PE治疗可提高鱼胆中毒儿童的抢救成功率。%Objective To investigate the efficacy and safety of plasma exchange (PE) to treat fish bile poisoning in children. Methods A total of 11 children suffering from fish bile poisoning were included in the current study. All patients presented obvious hepatic damage and were provided with PE therapy 2 to 20 h after admission in addition to routine therapy to relieve symptoms. Then, clinical symptoms and vital sign changes were observed before and after PE therapy. Meanwhile, venous blood samples were collected from those children before PE treatment, immediately after PE treatment, 3 d after PE treatment and 7 d after PE treatment to monitor biochemical changes. Results After PE treatment, clinical symptoms quickly disappeared in those children. During PE treatment, these patients presented stable mean arterial pressure (MAP), heart rate (HR), respiratory rate (RR) and saturation of pulse oximetry (SpO2) and other vital signs. Statistical differences exist in the

  1. Application of plasma exchange therapy and its adverse reactions observed in the clinical treatment of autoimmune dis -eases in neurology%血浆置换联合药物治疗在神经内科免疫疾病临床治疗中的应用及不良反应观察

    Institute of Scientific and Technical Information of China (English)

    刘世俊; 辜敏

    2015-01-01

    Objective To investigate the application of plasma exchange therapy and its adverse reactions in the clinical treatment of neurological autoimmune diseases .Methods A total of 90 patients of autoimmune diseases were selected from April 2012 to April 2014 in Department of Neurology of our hospital ,including 51 males and 39 females .All patients were randomly divided into plasma exchange group (n = 30) ,treatment group ( n = 30) and plasmapheresis combined treatment group ( n = 30) ,which were observed for each patient outcomes and ad‐verse events .Results The efficiency is 97% in plasma exchange combined with oral administration of globulin and prednisone tablets .It is higher than those of the patients in single drug treatment and plasmapheresis alone group . While the incidence of adverse reactions observed in patients showed that the combined incidence of adverse reac ‐tions in patients in drug treatment group was lower than that in plasma exchange group .It is of significant differ‐ence ( P < 0 .05) .Conclusion Plasma exchange treatment of autoimmune diseases and neurological diseases was of 3 significant effects .When treated through combination with the drug ,the effect were better and adverse reactions were reduced.%目的:探讨血浆置换联合药物治疗在神经内科免疫疾病临床治疗中的应用及不良反应发生情况。方法选取2012年4月至2014年4月在本院神经内科进行治疗的免疫疾病患者共90例,其中男性51例,女性39例,将所有患者随机分为血浆置换组、药物治疗组、血浆置换联合药物治疗组,每组30例患者,观察每组患者治疗效果及不良反应发生情况。结果通过血浆置换联合丙球球蛋白及泼尼松片口服,患者有效率97%,高于单独药物治疗和单独血浆置换患者,同时,观察患者不良反应发生情况发现,联合治疗组患者不良反应发生率低于药物治疗组和单独血浆置换组

  2. Plasma turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Horton, W. [Univ. of Texas, Austin, TX (United States). Inst. for Fusion Studies; Hu, G. [Globalstar LP, San Jose, CA (United States)

    1998-07-01

    The origin of plasma turbulence from currents and spatial gradients in plasmas is described and shown to lead to the dominant transport mechanism in many plasma regimes. A wide variety of turbulent transport mechanism exists in plasmas. In this survey the authors summarize some of the universally observed plasma transport rates.

  3. VT Telephone Exchange Boundaries

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The UtilityTelecom_EXCHANGE represents Vermont Telephone Exchange boundaries as defined by the VT Public Service Board. The original data was...

  4. Indiana Health Information Exchange

    Science.gov (United States)

    The Indiana Health Information Exchange is comprised of various Indiana health care institutions, established to help improve patient safety and is recognized as a best practice for health information exchange.

  5. Plasma harmonics

    CERN Document Server

    Ganeev, Rashid A

    2014-01-01

    Preface; Why plasma harmonics? A very brief introduction Early stage of plasma harmonic studies - hopes and frustrations New developments in plasma harmonics studies: first successes Improvements of plasma harmonics; Theoretical basics of plasma harmonics; Basics of HHG Harmonic generation in fullerenes using few-cycle pulsesVarious approaches for description of observed peculiarities of resonant enhancement of a single harmonic in laser plasmaTwo-colour pump resonance-induced enhancement of odd and even harmonics from a tin plasmaCalculations of single harmonic generation from Mn plasma;Low-o

  6. Approximate strip exchanging.

    Science.gov (United States)

    Roy, Swapnoneel; Thakur, Ashok Kumar

    2008-01-01

    Genome rearrangements have been modelled by a variety of primitives such as reversals, transpositions, block moves and block interchanges. We consider such a genome rearrangement primitive Strip Exchanges. Given a permutation, the challenge is to sort it by using minimum number of strip exchanges. A strip exchanging move interchanges the positions of two chosen strips so that they merge with other strips. The strip exchange problem is to sort a permutation using minimum number of strip exchanges. We present here the first non-trivial 2-approximation algorithm to this problem. We also observe that sorting by strip-exchanges is fixed-parameter-tractable. Lastly we discuss the application of strip exchanges in a different area Optical Character Recognition (OCR) with an example.

  7. Dusty plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Fortov, Vladimir E; Khrapak, Aleksei G; Molotkov, Vladimir I; Petrov, Oleg F [Institute for High Energy Densities, Associated Institute for High Temperatures, Russian Academy of Sciences, Moscow (Russian Federation); Khrapak, Sergei A [Max-Planck-Institut fur Extraterrestrische Physik, Garching (Germany)

    2004-05-31

    The properties of dusty plasmas - low-temperature plasmas containing charged macroparticles - are considered. The most important elementary processes in dusty plasmas and the forces acting on dust particles are investigated. The results of experimental and theoretical investigations of different states of strongly nonideal dusty plasmas - crystal-like, liquid-like, gas-like - are summarized. Waves and oscillations in dusty plasmas, as well as their damping and instability mechanisms, are studied. Some results on dusty plasma investigated under microgravity conditions are presented. New directions of experimental research and potential applications of dusty plasmas are discussed. (reviews of topical problems)

  8. 激素免疫抑制剂及其联合血浆置换治疗ANCA相关性血管炎的疗效比较%Clinical effect comparison of hormone immunosuppressive agents and its combination with plasma exchange in treatment of ANCA related vasculitis

    Institute of Scientific and Technical Information of China (English)

    韩晓文

    2015-01-01

    Objective To review and study clinical effect of hormone immunosuppressive agents and its combination with plasma exchange in treatment of ANCA related vasculitis.Methods collect materials of 35 cases patients diagnosed by pathology as AAV in department of rheumatism and nephrology of Baotou city central hospital with clinical manifestations of with acute nephritis syndrome. 25 case of them received methylprednisolone (0.5 g, 0.8g, 0.8g), later with sufficient hormone and cyclophosphamide (0.6 measurement semimonthly), which is normal treatment group. The rest10 patients received combination with plasma exchange therapy on the basis of former therapy, which is combination treatment group. Compare two groups with clinical effect 6 months before and after treatment. Results (1) after treatment, ANCA in serum of two groups was significantly decreased (P0.05), and BUN difference of normal group showed statistical significance from that before treatment(P0.05).Conclusion hormone immunosuppressive agents only and its combination with plasma exchange shows remarkable effect in treatment of ANCA, and its combination with plasma exchange has better effect for improvement of renal function and ANCA clearance with good safety.%目的:回顾性研究激素免疫抑制剂及其联合血浆置换治疗ANCA相关性血管炎的疗效。方法收集包头市中心医院肾内风湿科经病理确诊为 AAV,且临床表现符合急进性肾小球肾炎综合征的患者资料共35例,其中25例予以甲泼尼龙冲击治疗(0.5 g、0.8g、0.8g),后减为足量激素+环磷酰胺(计量0.6半月一次)简称为普通治疗组;余10例患者除上述药物治疗,还联合血浆置换治疗,简称联合治疗组;比较2组患者治疗前、治疗后6个月的临床疗效。结果(1)治疗后两组患者血清 ANCA均较治疗前明显下降(P0.05),而普通组相对于治疗前差异则有统计学意义(P0.05)。结论单独激素免疫抑制

  9. On the contribution of exchange interactions to the Vlasov equation

    CERN Document Server

    Zamanian, J; Marklund, M

    2014-01-01

    Exchange effects play an important role in determining the equilibrium properties of dense matter systems, as well as for magnetic phenomena. There exists an extensive literature concerning, e.g., the effects of exchange interactions on the equation of state of dense matter. Here, a generalization of the Vlasov equation to include exchange effects is presented allowing for electromagnetic mean fields, thus incorporating some of the dynamic effects due to the exchange interactions. Treating the exchange term perturbatively, the correction to classical Langmuir waves in plasmas is found, and the results are compared with previous work. It is noted that the relative importance of exchange effects scales similarly with density and temperature as particle dispersive effects, but that the overall magnitude is sensitive to the details of the specific problem. The implications of our results are discussed.

  10. Adaptively Compressed Exchange Operator

    CERN Document Server

    Lin, Lin

    2016-01-01

    The Fock exchange operator plays a central role in modern quantum chemistry. The large computational cost associated with the Fock exchange operator hinders Hartree-Fock calculations and Kohn-Sham density functional theory calculations with hybrid exchange-correlation functionals, even for systems consisting of hundreds of atoms. We develop the adaptively compressed exchange operator (ACE) formulation, which greatly reduces the computational cost associated with the Fock exchange operator without loss of accuracy. The ACE formulation does not depend on the size of the band gap, and thus can be applied to insulating, semiconducting as well as metallic systems. In an iterative framework for solving Hartree-Fock-like systems, the ACE formulation only requires moderate modification of the code, and can be potentially beneficial for all electronic structure software packages involving exchange calculations. Numerical results indicate that the ACE formulation can become advantageous even for small systems with tens...

  11. Laser Processed Heat Exchangers

    Science.gov (United States)

    Hansen, Scott

    2017-01-01

    The Laser Processed Heat Exchanger project will investigate the use of laser processed surfaces to reduce mass and volume in liquid/liquid heat exchangers as well as the replacement of the harmful and problematic coatings of the Condensing Heat Exchangers (CHX). For this project, two scale unit test articles will be designed, manufactured, and tested. These two units are a high efficiency liquid/liquid HX and a high reliability CHX.

  12. Microsoft Exchange 2013 cookbook

    CERN Document Server

    Van Horenbeeck, Michael

    2013-01-01

    This book is a practical, hands-on guide that provides the reader with a number of clear, step-by-step exercises.""Microsoft Exchange 2013 Cookbook"" is targeted at network administrators who deal with the Exchange server in their day-to-day jobs. It assumes you have some practical experience with previous versions of Exchange (although this is not a requirement), without being a subject matter expert.

  13. Plasma Discharge Process in a Pulsed Diaphragm Discharge System

    Science.gov (United States)

    Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu

    2014-12-01

    As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.

  14. Plasma waves

    CERN Document Server

    Swanson, DG

    1989-01-01

    Plasma Waves discusses the basic development and equations for the many aspects of plasma waves. The book is organized into two major parts, examining both linear and nonlinear plasma waves in the eight chapters it encompasses. After briefly discussing the properties and applications of plasma wave, the book goes on examining the wave types in a cold, magnetized plasma and the general forms of the dispersion relation that characterize the waves and label the various types of solutions. Chapters 3 and 4 analyze the acoustic phenomena through the fluid model of plasma and the kinetic effects. Th

  15. Plasma astrophysics

    CERN Document Server

    Kaplan, S A; ter Haar, D

    2013-01-01

    Plasma Astrophysics is a translation from the Russian language; the topics discussed are based on lectures given by V.N. Tsytovich at several universities. The book describes the physics of the various phenomena and their mathematical formulation connected with plasma astrophysics. This book also explains the theory of the interaction of fast particles plasma, their radiation activities, as well as the plasma behavior when exposed to a very strong magnetic field. The text describes the nature of collective plasma processes and of plasma turbulence. One author explains the method of elementary

  16. Usable optimistic fair exchange

    OpenAIRE

    Küpçü, Alptekin; Lysyanskaya, A.

    2012-01-01

    Fairly exchanging digital content is an everyday problem. It has been shown that fair exchange cannot be achieved without a trusted third party (called the Arbiter). Yet, even with a trusted party, it is still non-trivial to come up with an efficient solution, especially one that can be used in a p2p file sharing system with a high volume of data exchanged. We provide an efficient optimistic fair exchange mechanism for bartering digital files, where receiving a payment in return for a file (b...

  17. Exchange rate regime choice

    Directory of Open Access Journals (Sweden)

    Beker Emilija

    2006-01-01

    Full Text Available The choice of an adequate exchange rate regime proves to be a highly sensitive field within which the economic authorities present and confirm themselves. The advantages and disadvantages of fixed and flexible exchange rate regimes, which have been quite relativized from the conventional point of view, together with simultaneous, but not synchronized effects of structural and external factors, remain permanently questioned throughout a complex process of exchange rate regime decision making. The paper reflects the attempt of critical identification of the key exchange rate performances with emphasis on continuous non-uniformity and (uncertainty of shelf life of a relevant choice.

  18. Optimization of Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Ivan Catton

    2010-10-01

    The objective of this research is to develop tools to design and optimize heat exchangers (HE) and compact heat exchangers (CHE) for intermediate loop heat transport systems found in the very high temperature reator (VHTR) and other Generation IV designs by addressing heat transfer surface augmentation and conjugate modeling. To optimize heat exchanger, a fast running model must be created that will allow for multiple designs to be compared quickly. To model a heat exchanger, volume averaging theory, VAT, is used. VAT allows for the conservation of mass, momentum and energy to be solved for point by point in a 3 dimensional computer model of a heat exchanger. The end product of this project is a computer code that can predict an optimal configuration for a heat exchanger given only a few constraints (input fluids, size, cost, etc.). As VAT computer code can be used to model characteristics )pumping power, temperatures, and cost) of heat exchangers more quickly than traditional CFD or experiment, optimization of every geometric parameter simultaneously can be made. Using design of experiment, DOE and genetric algorithms, GE, to optimize the results of the computer code will improve heat exchanger disign.

  19. Building Relationships through Exchange

    Science.gov (United States)

    Primavera, Angi; Hall, Ellen

    2011-01-01

    From the moment of birth, children form and develop relationships with others in their world based on exchange. Children recognize that engaging in such encounters offers them the opportunity to enter into a relationship with another individual and to nurture that relationship through the exchange of messages and gifts, items and ideas. At Boulder…

  20. Aberration Corrected Emittance Exchange

    CERN Document Server

    Nanni, Emilio A

    2015-01-01

    Full exploitation of emittance exchange (EEX) requires aberration-free performance of a complex imaging system including active radio-frequency (RF) elements which can add temporal distortions. We investigate the performance of an EEX line where the exchange occurs between two dimensions with normalized emittances which differ by orders of magnitude. The transverse emittance is exchanged into the longitudinal dimension using a double dog-leg emittance exchange setup with a 5 cell RF deflector cavity. Aberration correction is performed on the four most dominant aberrations. These include temporal aberrations that are corrected with higher order magnetic optical elements located where longitudinal and transverse emittance are coupled. We demonstrate aberration-free performance of emittances differing by 4 orders of magnitude, i.e. an initial transverse emittance of $\\epsilon_x=1$ pm-rad is exchanged with a longitudinal emittance of $\\epsilon_z=10$ nm-rad.

  1. Lowering of plasma phospholipid transfer protein activity by acute hyperglycaemia-induced hyperinsulinaemia in healthy men

    NARCIS (Netherlands)

    vanTol, A; Ligtenberg, JJM; Riemens, SC; vanHaeften, TW; Dullaart, RPF

    1997-01-01

    Human plasma contains two lipid transfer proteins involved in the remodelling of plasma lipoproteins: cholesteryl ester transfer protein (CETP) and phospholipid transfer protein (PLTP). CETP mediates the transfer/exchange of cholesterylesters, triglycerides and phospholipids between high-density lip

  2. Determination of aminopolycarboxylic acids at ultra-trace levels by means of online coupling ion exchange chromatography and inductively coupled plasma-mass spectrometry with indirect detection via their Pd²⁺-complexes.

    Science.gov (United States)

    Nette, David; Seubert, Andreas

    2015-07-16

    A new indirect IC-ICP-MS method for the determination of aminopolycarboxylic acids in water samples is described. It is based on the addition of an excess of Pd(II) to water samples. The analytes are forced into very strong and negatively charged palladium complexes, separated by ion exchange chromatography and detected by their palladium content, utilizing an on-line coupled ICP-MS. This method is suitable to determine the concentration of 8 aminopolycarboxylic acids (nitrilotriacetic acid (NTA), (2-carboxyethyl) iminodiacetic acid (β-ADA), methylglycinediacetic acid (MGDA), 2-hydroxyethyl) ethylenediamine triacetic acid (HEDTA), diethylene triamine pentaacetic acid (DTPA), ethylendiamine tetraacetic acid (EDTA), 1,3-diaminopropane tetraacetic acid (1,3-PDTA) and 1,2-diaminopropane tetraacetic acid (1,2-PDTA) at the ng kg(-1) level. The method is faster and easier than the established gas chromatography (GC)-method ISO 16588:2002 and up to two orders of magnitude more sensitive than the ion pair chromatography based method of DIN 38413-8. Analytic performance is superior to ISO 16588:2002 and the comparability is good. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Anion exchange membrane

    Science.gov (United States)

    Verkade, John G; Wadhwa, Kuldeep; Kong, Xueqian; Schmidt-Rohr, Klaus

    2013-05-07

    An anion exchange membrane and fuel cell incorporating the anion exchange membrane are detailed in which proazaphosphatrane and azaphosphatrane cations are covalently bonded to a sulfonated fluoropolymer support along with anionic counterions. A positive charge is dispersed in the aforementioned cations which are buried in the support to reduce the cation-anion interactions and increase the mobility of hydroxide ions, for example, across the membrane. The anion exchange membrane has the ability to operate at high temperatures and in highly alkaline environments with high conductivity and low resistance.

  4. Heat exchanger design handbook

    CERN Document Server

    Thulukkanam, Kuppan

    2013-01-01

    Completely revised and updated to reflect current advances in heat exchanger technology, Heat Exchanger Design Handbook, Second Edition includes enhanced figures and thermal effectiveness charts, tables, new chapter, and additional topics--all while keeping the qualities that made the first edition a centerpiece of information for practicing engineers, research, engineers, academicians, designers, and manufacturers involved in heat exchange between two or more fluids.See What's New in the Second Edition: Updated information on pressure vessel codes, manufacturer's association standards A new c

  5. Exchange Rate in Focus

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    China announced the reform of its decade-old RMB exchange rate regime last July, linking the RMB to a basket of currencies rather than the U.S. dollar alone, and allowing the RMB to appreciate 2 percent against the U.S. currency. Since then, different viewpoints on the new regime have been voiced. The People's Bank of China, the central bank, said in a statement in late March that it would further improve the system, broadening the foreign exchange market, increasing the flexibility of the RMB exchange r...

  6. Two-component model of the interaction of an interstellar cloud with surrounding hot plasma

    OpenAIRE

    Provornikova, E. A.; Izmodenov, V. V.; Lallement, R.

    2011-01-01

    We present a two-component gasdynamic model of an interstellar cloud embedded in a hot plasma. It is assumed that the cloud consists of atomic hydrogen gas, interstellar plasma is quasineutral. Hydrogen atoms and plasma protons interact through a charge exchange process. Magnetic felds and radiative processes are ignored in the model. The influence of heat conduction within plasma on the interaction between a cloud and plasma is studied. We consider the extreme case and assume that hot plasma...

  7. Determination of aminopolycarboxylic acids at ultra-trace levels by means of online coupling ion exchange chromatography and inductively coupled plasma-mass spectrometry with indirect detection via their Pd{sup 2+}-complexes

    Energy Technology Data Exchange (ETDEWEB)

    Nette, David; Seubert, Andreas, E-mail: seubert@staff.uni-marburg.de

    2015-07-16

    Highlights: • 8 important APCA’s analyzed in one run instead of 3 in the previous method. • Pd{sup 2+} extents the methods applicability to 3 and more dentate amino carboxylic acids. • Separation system optimized for the isocratic determination of important APCA’s. • Thermodynamic stability of APCA–Pd{sup 2+} complexes is higher than for Fe{sup 3+} and In{sup 3+}. • Pd{sup 2+} is kinetically much slower than Fe{sup 3+} and In{sup 3+} and makes the method more rugged. - Abstract: A new indirect IC-ICP-MS method for the determination of aminopolycarboxylic acids in water samples is described. It is based on the addition of an excess of Pd(II) to water samples. The analytes are forced into very strong and negatively charged palladium complexes, separated by ion exchange chromatography and detected by their palladium content, utilizing an on-line coupled ICP-MS. This method is suitable to determine the concentration of 8 aminopolycarboxylic acids (nitrilotriacetic acid (NTA), (2-carboxyethyl) iminodiacetic acid (β-ADA), methylglycinediacetic acid (MGDA), 2-hydroxyethyl) ethylenediamine triacetic acid (HEDTA), diethylene triamine pentaacetic acid (DTPA), ethylendiamine tetraacetic acid (EDTA), 1,3-diaminopropane tetraacetic acid (1,3-PDTA) and 1,2-diaminopropane tetraacetic acid (1,2-PDTA) at the ng kg{sup −1} level. The method is faster and easier than the established gas chromatography (GC)-method ISO 16588:2002 [1] and up to two orders of magnitude more sensitive than the ion pair chromatography based method of DIN 38413-8. Analytic performance is superior to ISO 16588:2002 and the comparability is good.

  8. Optimization of an anion-exchange high performance liquid chromatography-inductively coupled plasma-mass spectrometric method for the speciation analysis of oxyanion-forming metals and metalloids in leachates from cement-based materials.

    Science.gov (United States)

    Mulugeta, Mesay; Wibetoe, Grethe; Engelsen, Christian J; Lund, Walter

    2010-10-01

    A method was developed for the speciation analysis of the oxyanions of As(III), As(V), Cr(VI), Mo(VI), Sb(III), Sb(V), Se(IV), Se(VI) and V(V) in leachates from cement-based materials, based on anion-exchange HPLC coupled with ICP-MS. The method was optimized in a two-step multivariate approach: the effect of sample pH and mobile phase composition on resolution, peak symmetry and analysis time was studied. Optimum conditions were then identified for the significant experimental factors by studying their interdependence. A mobile phase composition of 20 mM ammonium nitrate, 50 mM ammonium tartrate and pH 9.5 was found to be a compromise optimum for the separation of the target analytes using isocratic elution. The optimum condition provided separation of the analytes in less than 6 min, at a mobile phase flow rate of 1.0 mL/min. The signal intensities of the analytes were improved by adding 1% methanol to the mobile phase. The limit of detection of the method was in the range 0.2-2.2 μg/L for the various species. The effect of sample constituents was studied using spiked concrete leachates. The method was used to determine the target oxyanionic species in leachates generated from a concrete material in the pH range 3.5-12.4; CrO(4)(2-), MoO(4)(2-) and VO(4)(3-) were detected in most of the leachates.

  9. Data Exchange Inventory System (DEXI)

    Data.gov (United States)

    Social Security Administration — Enterprise tool used to identify data exchanges occurring between SSA and our trading partners. DEXI contains information on both incoming and outgoing exchanges and...

  10. Exchange Risk Management Policy

    CERN Document Server

    2005-01-01

    At the Finance Committee of March 2005, following a comment by the CERN Audit Committee, the Chairman invited the Management to prepare a document on exchange risk management policy. The Finance Committee is invited to take note of this document.

  11. NASA Earth Exchange (NEX)

    Data.gov (United States)

    National Aeronautics and Space Administration — The NASA Earth Exchange (NEX) represents a new platform for the Earth science community that provides a mechanism for scientific collaboration and knowledge sharing....

  12. Active microchannel heat exchanger

    Science.gov (United States)

    Tonkovich, Anna Lee Y [Pasco, WA; Roberts, Gary L [West Richland, WA; Call, Charles J [Pasco, WA; Wegeng, Robert S [Richland, WA; Wang, Yong [Richland, WA

    2001-01-01

    The present invention is an active microchannel heat exchanger with an active heat source and with microchannel architecture. The microchannel heat exchanger has (a) an exothermic reaction chamber; (b) an exhaust chamber; and (c) a heat exchanger chamber in thermal contact with the exhaust chamber, wherein (d) heat from the exothermic reaction chamber is convected by an exothermic reaction exhaust through the exhaust chamber and by conduction through a containment wall to the working fluid in the heat exchanger chamber thereby raising a temperature of the working fluid. The invention is particularly useful as a liquid fuel vaporizer and/or a steam generator for fuel cell power systems, and as a heat source for sustaining endothermic chemical reactions and initiating exothermic reactions.

  13. Emittance exchange results

    Energy Technology Data Exchange (ETDEWEB)

    Fliller, R.P., III; /Brookhaven; Koeth, T.; /Rutgers U., Piscataway

    2009-09-01

    The promise of next-generation light sources depends on the availability of ultra-low emittance electron sources. One method of producing low transverse emittance beams is to generate a low longitudinal emittance beam and exchange it with a large transverse emittance. Experiments are underway at Fermilab's A0 Photoinjector and ANL's Argonne Wakefield Accelerator using the exchange scheme of Kim and Sessler. The experiment at the A0 Photoinjector exchanges a large longitudinal emittance with a small transverse emittance. AWA expects to exchange a large transverse emittance with a small longitudinal emittance. In this paper we discuss recent results at A0 and AWA and future plans for these experiments.

  14. Emittance Exchange Results

    Energy Technology Data Exchange (ETDEWEB)

    Fliller III,R.; Koeth, T.

    2009-05-04

    The promise of next-generation light sources depends on the availability of ultra-low emittance electron sources. One method of producing low transverse emittance beams is to generate a low longitudinal emittance beam and exchange it with a large transverse emittance. Experiments are underway at Fermilab's A0 Photoinjector and ANL's Argonne Wakefield Accelerator using the exchange scheme of Kim and Sessler. The experiment at the A0 Photoinjector exchanges a large longitudinal emittance with a small transverse emittance. AWA expects to exchange a large transverse emittance with a small longitudinal emittance. In this paper we discuss recent results at A0 and AWA and future plans for these experiments.

  15. Microplate Heat Exchanger Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose a microplate heat exchanger for cryogenic cooling systems used for continuous flow distributed cooling systems, large focal plane arrays, multiple cooling...

  16. HUD Exchange Grantee Database

    Data.gov (United States)

    Department of Housing and Urban Development — The About Grantees section of the HUD Exchange brings up contact information, reports, award, jurisdiction, and location data for organizations that receive HUD...

  17. Compact, super heat exchanger

    Science.gov (United States)

    Fortini, A.; Kazaroff, J. M.

    1980-01-01

    Heat exchanger uses porous media to enhance heat transfer through walls of cooling channels, thereby lowering wall temperature. Porous media within cooling channel increases internal surface area from which heat can be transferred to coolant. Comparison data shows wall has lower temperature and coolant has higher temperature when porous medium is used within heat exchanger. Media can be sintered powedered metal, metal fibers, woven wire layers, or any porous metal having desired permeability and porosity.

  18. Plasma Antenna

    OpenAIRE

    N M Vijay

    2014-01-01

    The fundamental base of plasma antenna is the use of an ionized medium as a conductor. The plasma antenna is a radiofrequency antenna formed by a plasma columns, Filaments or sheets, which are excited by a surface wave. The relevance of this device is how rapidly it can be turned on and off, only applying an electrical pulse. Besides its wide carrier frequency, the great directivity and controllable antenna shape. Otherwise a disadvantage is that it needs energy to be ionized....

  19. Private Health Insurance Exchanges

    Science.gov (United States)

    Buttorff, Christine; Nowak, Sarah; Syme, James; Eibner, Christine

    2017-01-01

    Abstract Private health insurance exchanges offer employer health insurance, combining online shopping, increased plan choice, benefit administration, and cost-containment strategies. This article examines how private exchanges function, how they may affect employers and employees, and the possible implications for the Affordable Care Act's (ACA's) Small Business Health Options Program (SHOP) Marketplaces. The authors found that private exchanges could encourage employees to select less-generous plans. This could expose employees to higher out-of-pocket costs, but premium contributions would drop substantially, so net spending would decrease. On the other hand, employee spending may increase if, in moving to private exchanges, employers decrease their health insurance contributions. Most employers can avoid the ACA's “Cadillac tax” by reducing the generosity of the plans they offer, regardless of whether they move to a private exchange. There is not yet enough evidence to determine whether the private exchanges will become prominent in the insurance market and how they will affect employers and their employees. PMID:28845340

  20. NafionTM膜表面改性用等离子体聚合方法提高膜的阳离子选择性%Surface Modification of Ion Exchange Membrane(NafionTM) The Enhancement of Cation Selectivity by Plasma Polymerization Process

    Institute of Scientific and Technical Information of China (English)

    曾蓉; 朱鹤孙; 庞志成; 弋峰

    2001-01-01

    An ultra-thin anionic exchange layer containing —NH2 and —CONH2 was deposited on the surface of NafionTM membrane. This layer was deposited from ethylene and ammonia using a glow-discharge plasma polymerization technique. The SEM, ATR(attenuated total reflection) spectra and XPS(X-ray photoelectron spectroscopy) showed that the resulted plasma polymers containing —NH2 and —CONH2 was about 0.5 μm thick. The proton perm-selectivity of plasma-modified NafionTM membrane was expressed by tCu, the transference number of the Cu2+ ion through the membrane which was determined by using NafionTM membrane as the separator in a typical two-compartment cell(0.25 mol/L CuCl2-0.5mol/L HCl|plasma-modified NafionTM membrane|1 mol/L HCl). Pretreatment of the NafionTM membrane by oxygen sputtering enhanced the adhesion of plasma polymer onto its surface. The plasma-treated membrane exhibited a high perm-selectivity and its resistance in 1 mol/L HCl was only a little bit higher than NafionTM membrane(<0.5 Ω*cm2).%采用辉光放电等离子体聚合方法, 以C2H4和NH3为单体, 在NafionTM膜表面沉积一层含氨基及酰氨基的类聚乙烯阴离子交换膜, 提高了NafionTM膜对阳离子的选择性, 同时不显著增加膜电阻. 由SEM确定该等离子体聚合膜厚约0.5 μm, 用红外光谱及X光电子能谱表征膜结构. 采用四电极法测量膜电阻, 膜对质子的选择性由Cu2+的迁移数tCu表征, 用二室隔膜装置(0.25 mol/L CuCl2-0.5 mol/L HCl|等离子体处理膜|1 mol/L HCl)测量tCu. O2等离子体预处理NafionTM膜有利于沉积膜在NafionTM膜上的沉积并与NafionTM膜紧密结合. 经改性后的NafionTM膜电阻值仍然很小, 在1 mol/L HCl溶液中电阻小于0.5 Ω*cm2.

  1. Plasma physics

    CERN Document Server

    Drummond, James E

    2013-01-01

    A historic snapshot of the field of plasma physics, this fifty-year-old volume offers an edited collection of papers by pioneering experts in the field. In addition to assisting students in their understanding of the foundations of classical plasma physics, it provides a source of historic context for modern physicists. Highly successful upon its initial publication, this book was the standard text on plasma physics throughout the 1960s and 70s.Hailed by Science magazine as a ""well executed venture,"" the three-part treatment ranges from basic plasma theory to magnetohydrodynamics and microwa

  2. Treatment of Alzheimer disease using combination therapy with plasma exchange and haemapheresis with albumin and intravenous immunoglobulin: Rationale and treatment approach of the AMBAR (Alzheimer Management By Albumin Replacement) study.

    Science.gov (United States)

    Boada, M; Ramos-Fernández, E; Guivernau, B; Muñoz, F J; Costa, M; Ortiz, A M; Jorquera, J I; Núñez, L; Torres, M; Páez, A

    2016-09-01

    There is a growing interest in new therapeutic strategies for the treatment of Alzheimer disease (AD) which focus on reducing the beta-amyloid peptide (Aβ) burden in the brain by sequestering plasma Aβ, a large proportion of which is bound to albumin and other proteins. This review discusses the concepts of interaction between Aβ and albumin that have given rise to AMBAR (Alzheimer's Disease Management by Albumin Replacement) project, a new multicentre, randomised, controlled clinical trial for the treatment of AD. Results from preliminary research suggest that Albutein(®) (therapeutic albumin, Grifols) contains no quantifiable levels of Aβ. Studies also show that Albutein(®) has Aβ binding capacity. On the other hand, AD entails a high level of nitro-oxidative stress associated with fibrillar aggregates of Aβ that can induce albumin modification, thus affecting its biological functions. Results from the phase ii study confirm that using therapeutic apheresis to replace endogenous albumin with Albutein(®) 5% is feasible and safe in patients with AD. This process resulted in mobilisation of Aβ and cognitive improvement in treated patients. The AMBAR study will test combination therapy with therapeutic apheresis and haemopheresis with the possible leverage effect of Albutein(®) with intravenous immunoglobulin replacement (Flebogamma(®) DIF). Cognitive, functional, and behavioural changes in patients with mild to moderate AD will be assessed. the AMBAR study represents a new therapeutic perspective for AD. Copyright © 2014 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. High-beta plasma blobs in the morningside plasma sheet

    Directory of Open Access Journals (Sweden)

    G. Haerendel

    Full Text Available Equator-S frequently encountered, i.e. on 30% of the orbits between 1 March and 17 April 1998, strong variations of the magnetic field strength of typically 5–15-min duration outside about 9RE during the late-night/early-morning hours. Very high-plasma beta values were found, varying between 1 and 10 or more. Close conjunctions between Equator-S and Geotail revealed the spatial structure of these "plasma blobs" and their lifetime. They are typically 5–10° wide in longitude and have an antisymmetric plasma or magnetic pressure distribution with respect to the equator, while being altogether low-latitude phenomena 
    (≤ 15°. They drift slowly sunward, exchange plasma across the equator and have a lifetime of at least 15–30 min. While their spatial structure may be due to some sort of mirror instability, little is known about the origin of the high-beta plasma. It is speculated that the morningside boundary layer somewhat further tailward may be the source of this plasma. This would be consistent with the preference of the plasma blobs to occur during quiet conditions, although they are also found during substorm periods. The relation to auroral phenomena in the morningside oval is uncertain. The energy deposition may be mostly too weak to generate a visible signature. However, patchy aurora remains a candidate for more disturbed periods.

    Key words. Magnetospheric physics (plasma convection; plasma sheet; plasma waves and instabilities

  4. Modeling the Europa plasma torus

    Science.gov (United States)

    Schreier, Ron; Eviatar, Aharon; Vasyliunas, Vytenis M.; Richardson, John D.

    1993-12-01

    The existence of a torus of plasma generated by sputtering from Jupiter's satellite Europa has long been suspected but never yet convincingly demonstrated. Temperature profiles from Voyager plasma observations indicate the presence of hot, possibly freshly picked-up ions in the general vicinity of the orbit of Europa, which may be interpreted as evidence for a local plasma torus. Studies of ion partitioning in the outer regions of the Io torus reveal that the oxygen to sulfur mixing ratio varies with radial distance; this may indicates that oxygen-rich matter is injected from a non-Io source, most probably Europa. We have constructed a quantitative model of a plasma torus near the orbit of Europa which takes into account plasma input from the Io torus, sputtering from the surface of Europa, a great number of ionization and charge exchange processes, and plasma loss by diffusive transport. When the transport time is chosen so that the model's total number density in consistent with the observed total plasma density, the contribution from Europa is found to be significant although not dominant. The model predicts in detail the ion composition, charge states, and the relative fractions of hot Europa-generated and (presumed) cold Io-generated ions. The results are generally consistent with observations from Voyager and can in principle (subject to limitations of data coverage) be confirmed in more detail by Ulysses.

  5. Exchanging Description Logic Knowledge Bases

    NARCIS (Netherlands)

    Arenas, M.; Botoeva, E.; Calvanese, D.; Ryzhikov, V.; Sherkhonov, E.

    2012-01-01

    In this paper, we study the problem of exchanging knowledge between a source and a target knowledge base (KB), connected through mappings. Differently from the traditional database exchange setting, which considers only the exchange of data, we are interested in exchanging implicit knowledge. As rep

  6. Heat exchanger restart evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, J.M.; Hirst, C.W.; Lentz, T.F.

    1992-02-28

    On December 24, 1991, the K-Reactor was in the shutdown mode with full AC process water flow and full cooling water flow. Safety rod testing was being performed as part of the power ascension testing program. The results of cooling water samples indicated tritium concentrations higher than allowable. Further sampling and testing confirmed a Process Water System to Cooling Water System leak in heat exchanger 4A (HX 4A). The heat exchanger was isolated and the plant shutdown. Heat exchanger 4kA was removed from the plant and moved to C-Area prior to performing examinations and diagnostic testing. This included locating and identifying the leaking tube or tubes, eddy current examination of the leaking tube and a number of adjacent tubes, visually inspecting the leaking tube from both the inside as well as the area surrounding the failure mechanism. In addition ten other tubes that either exhibited eddy current indications or would represent a baseline condition were removed from heat exchanger 4A for metallurgical examination. Additional analysis and review of heat exchanger leakage history was performed to determine if there are any patterns which can be used for predictive purposes. Compensatory actions have been taken to improve the sensitivity and response time to any future events of this type. The results of these actions are summarized herein.

  7. Ion exchange phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Bourg, I.C.; Sposito, G.

    2011-05-01

    Ion exchange phenomena involve the population of readily exchangeable ions, the subset of adsorbed solutes that balance the intrinsic surface charge and can be readily replaced by major background electrolyte ions (Sposito, 2008). These phenomena have occupied a central place in soil chemistry research since Way (1850) first showed that potassium uptake by soils resulted in the release of an equal quantity of moles of charge of calcium and magnesium. Ion exchange phenomena are now routinely modeled in studies of soil formation (White et al., 2005), soil reclamation (Kopittke et al., 2006), soil fertilitization (Agbenin and Yakubu, 2006), colloidal dispersion/flocculation (Charlet and Tournassat, 2005), the mechanics of argillaceous media (Gajo and Loret, 2007), aquitard pore water chemistry (Tournassat et al., 2008), and groundwater (Timms and Hendry, 2007; McNab et al., 2009) and contaminant hydrology (Chatterjee et al., 2008; van Oploo et al., 2008; Serrano et al., 2009).

  8. Microgravity condensing heat exchanger

    Science.gov (United States)

    Thomas, Christopher M. (Inventor); Ma, Yonghui (Inventor); North, Andrew (Inventor); Weislogel, Mark M. (Inventor)

    2011-01-01

    A heat exchanger having a plurality of heat exchanging aluminum fins with hydrophilic condensing surfaces which are stacked and clamped between two cold plates. The cold plates are aligned radially along a plane extending through the axis of a cylindrical duct and hold the stacked and clamped portions of the heat exchanging fins along the axis of the cylindrical duct. The fins extend outwardly from the clamped portions along approximately radial planes. The spacing between fins is symmetric about the cold plates, and are somewhat more closely spaced as the angle they make with the cold plates approaches 90.degree.. Passageways extend through the fins between vertex spaces which provide capillary storage and communicate with passageways formed in the stacked and clamped portions of the fins, which communicate with water drains connected to a pump externally to the duct. Water with no entrained air is drawn from the capillary spaces.

  9. Effective attraction between oscillating electrons in plasma

    CERN Document Server

    Dvornikov, Maxim

    2011-01-01

    We consider the effective interaction between electrons due to the exchange of virtual acoustic waves in low temperature plasma. Electrons are supposed to participate in rapid oscillations and form a spherically symmetric soliton like structure. We show that under certain conditions this effective interaction can result in the attraction between oscillating electrons and can be important for the dynamics of a plasmoid. Some possible applications of the obtained results to the theory of natural long lived plasma structures are also discussed.

  10. Tuning Exchange Anisotropy of Exchange-Biased System

    Institute of Scientific and Technical Information of China (English)

    XU Yan; HU Jing-Guo; R.L.Stamps

    2008-01-01

    Exchange anisotropy in FM/AFM bilayers has given a lot of static magnetization properties such as enhanced coercivity and magnetization loop shifts.These phenomena are primarily from the effective anisotropies intro-duced into a ferromagnet by exchange coupling with a strongly anisotropic antiferromagnet.These effective anisotropies can also be used to explain the dynamic consequences of exchange-biased bilayers.In this article,the dynamic con-sequences such as exchange-induced susceptibility,exchange-induced permeability,and the corresponding domain wall characteristics in the exchange-biased structures of ferromagnet/antiferromagnetl/antiferromagnet2 are studied.The results show that the second antiferromagnetic layer can largely affect the dynamic consequences of exchange-biased bilayers.Especially in the ease of critical temperature,the effects become more obvious.Practically,the exchange anisotropy of biased bilayer system can be tuned by exchange coupling with the second antiferromagnetic layer.

  11. Plasma chromograninx

    DEFF Research Database (Denmark)

    Goetze, Jens P; Hilsted, Linda M; Rehfeld, Jens F

    2014-01-01

    Cardiovascular risk assessment remains difficult in elderly patients. We examined whether chromogranin A (CgA) measurement in plasma may be valuable in assessing risk of death in elderly patients with symptoms of heart failure in a primary care setting. A total of 470 patients (mean age 73 years......) were followed for 10 years. For CgA plasma measurement, we used a two-step method including a screening test and a confirmative test with plasma pre-treatment with trypsin. Cox multivariable proportional regression and receiver-operating curve (ROC) analyses were used to assess mortality risk...... of follow-up showed significant additive value of CgA confirm measurements compared with NT-proBNP and clinical variables. CgA measurement in the plasma of elderly patients with symptoms of heart failure can identify those at increased risk of short- and long-term mortality....

  12. Plasma Cleaning

    Science.gov (United States)

    Hintze, Paul E.

    2016-01-01

    NASA's Kennedy Space Center has developed two solvent-free precision cleaning techniques: plasma cleaning and supercritical carbon dioxide (SCCO2), that has equal performance, cost parity, and no environmental liability, as compared to existing solvent cleaning methods.

  13. Exchangeable lower previsions

    CERN Document Server

    de Cooman, Gert; Miranda, Enrique; 10.3150/09-BEJ182

    2009-01-01

    We extend de Finetti's [Ann. Inst. H. Poincar\\'{e} 7 (1937) 1--68] notion of exchangeability to finite and countable sequences of variables, when a subject's beliefs about them are modelled using coherent lower previsions rather than (linear) previsions. We derive representation theorems in both the finite and countable cases, in terms of sampling without and with replacement, respectively.

  14. Baltic Exchange toodi Tallinna

    Index Scriptorium Estoniae

    2007-01-01

    Viimane osa merekonteineritesse kokkupakitud Londoni laevandus- ja merebörsi Baltic Exchange'i endise peakorteri detailidest jõudis 2007. a. juunis Tallinna. Hoone detailid ostnud ärimehed Heiti Hääl ja Eerik-Niiles Kross plaanivad leida hoonele koha Tallinna kesklinnas. E.-N. Krossi kommentaar

  15. Telephone Exchange Maintenance

    CERN Multimedia

    2005-01-01

    Urgent maintenance work on CERN telephone exchanges will be performed on 24 March from 6 a.m. to 8 a.m. Telephone services may be disrupted or even interrupted during this time. For more details, please contact us by email at Standard.Telephone@cern.ch.

  16. Currency Exchange Rates.

    Science.gov (United States)

    Siler, Carl R.

    This curriculum unit of the Muncie (Indiana) Southside High School is to simulate the dynamics of foreign currency exchange rates from the perspectives of: (1) a major U.S. corporation, ABB Power T & D Company, Inc., of Muncie, Indiana, a manufacturer of large power transformers for the domestic and foreign markets; and (2) individual…

  17. Microtube strip heat exchanger

    Science.gov (United States)

    Doty, F. D.

    1991-04-01

    During the last quarter, Doty Scientific, Inc. (DSI) continued to make progress on the microtube strip (MTS) heat exchangers. The team has begun a heat exchanger stress analysis; however, they have been concentrating the bulk of their analytical energies on a computational fluid dynmaics (CFD) model to determine the location and magnitude of shell-side flow maldistribution which decreases heat exchanger effectiveness. DSI received 120 fineblanked tubestrips from Southern Fineblanking (SFB) for manufacturing process development. Both SFB and NIST provided inspection reports of the tubestrips. DSI completed the tooling required to encapsulate a tube array and press tubestrips on the array. Pressing the tubestrips on tube arrays showed design deficiencies both in the tubestrip design and the tooling design. DSI has a number of revisions in process to correct these deficiencies. The research effort has identified a more economical fusible alloy for encapsulating the tube array, and determined the parameters required to successfully encapsulate the tube array with the new alloy. A more compact MTS heat exchanger bank was designed.

  18. Nature's Heat Exchangers.

    Science.gov (United States)

    Barnes, George

    1991-01-01

    Discusses the heat-transfer systems of different animals. Systems include heat conduction into the ground, heat transferred by convection, heat exchange in lizards, fish and polar animals, the carotid rete system, electromagnetic radiation from animals and people, and plant and animal fiber optics. (MDH)

  19. Plasma confinement

    CERN Document Server

    Hazeltine, R D

    2003-01-01

    Detailed and authoritative, this volume examines the essential physics underlying international research in magnetic confinement fusion. It offers readable, thorough accounts of the fundamental concepts behind methods of confining plasma at or near thermonuclear conditions. Designed for a one- or two-semester graduate-level course in plasma physics, it also represents a valuable reference for professional physicists in controlled fusion and related disciplines.

  20. Counterflow Regolith Heat Exchanger

    Science.gov (United States)

    Zubrin, Robert; Jonscher, Peter

    2013-01-01

    A problem exists in reducing the total heating power required to extract oxygen from lunar regolith. All such processes require heating a great deal of soil, and the heat energy is wasted if it cannot be recycled from processed material back into new material. The counterflow regolith heat exchanger (CoRHE) is a device that transfers heat from hot regolith to cold regolith. The CoRHE is essentially a tube-in-tube heat exchanger with internal and external augers attached to the inner rotating tube to move the regolith. Hot regolith in the outer tube is moved in one direction by a right-hand - ed auger, and the cool regolith in the inner tube is moved in the opposite direction by a left-handed auger attached to the inside of the rotating tube. In this counterflow arrangement, a large fraction of the heat from the expended regolith is transferred to the new regolith. The spent regolith leaves the heat exchanger close to the temperature of the cold new regolith, and the new regolith is pre-heated close to the initial temperature of the spent regolith. Using the CoRHE can reduce the heating requirement of a lunar ISRU system by 80%, reducing the total power consumption by a factor of two. The unique feature of this system is that it allows for counterflow heat exchange to occur between solids, instead of liquids or gases, as is commonly done. In addition, in variants of this concept, the hydrogen reduction can be made to occur within the counterflow heat exchanger itself, enabling a simplified lunar ISRU (in situ resource utilization) system with excellent energy economy and continuous nonbatch mode operation.

  1. Analytical applications of ion exchangers

    CERN Document Server

    Inczédy, J

    1966-01-01

    Analytical Applications of Ion Exchangers presents the laboratory use of ion-exchange resins. This book discusses the development in the analytical application of ion exchangers. Organized into 10 chapters, this book begins with an overview of the history and significance of ion exchangers for technical purposes. This text then describes the properties of ion exchangers, which are large molecular water-insoluble polyelectrolytes having a cross-linked structure that contains ionic groups. Other chapters consider the theories concerning the operation of ion-exchange resins and investigate th

  2. 血浆置换联合药物治疗儿童重症系统性红斑狼疮的临床疗效%Clinical Efficacy of Plasma Exchange Combined with Drugs for the Treatment of Severe Systemic Lupus Erythematosus in Children

    Institute of Scientific and Technical Information of China (English)

    简讯; 罗晓英; 马懿; 胡诗德; 肖胜; 杨乔岚

    2013-01-01

    [目的]观察血浆置换联合激素、霉酚酸酯(MMF)治疗儿童重症系统性红斑狼疮(SLE)的临床疗效。[方法]回顾性分析入住本院的18例重症S L E患儿的临床资料,观察治疗前后患儿症状、体征(发热、关节疼痛、皮疹、水肿)缓解情况及抗SM抗体、抗ds-DNA抗体、抗RNP抗体、血沉(ESR)、24h尿蛋白、肌酐(SCr)及补体C3的变化。[结果]18例患儿经治疗后症状全部得到好转,其中12例面部红斑消失,2例患儿皮肤表面溃疡愈合,13例患儿雷诺现象消失,发热及关节疼痛明显缓解。ESR由治疗前的(92±24)mm/h降到(27±15)mm/h ,24 h尿蛋白由治疗前的(8.12±4.76)g降到(1.83±1.55)g ,抗SM抗体、抗ds-DNA抗体转阴率明显下降。[结论]血浆置换联合激素、MMF可降低血清自身抗体,有效控制儿童重症SLE ,值得临床推广应用。%[Objective] To observe the clinical efficacy of plasma exchange combined with corticoids and myco-phenolate mofetil(MMF) for the treatment of severe systemic lupus erythematosus (SLE) in children .[Methods]Clinical data of 18 children with severe SLE in our hospital were analyzed retrospectively .The improvement of symptoms and signs(fever ,joint pain ,rash ,edema) and anti-SM antibody ,anti-ds-DNA antibody ,anti-RNP anti-bodies ,blood sedimentation(ESR) ,24h urine protein ,serum creatinine(Scr) and complement C3 before and after treatment were observed .[Results]Symptoms of all the 18 patients got better after treatment .Facial erythema of 12 patients disappeared .Skin surface ulcer of 2 patients was healed .Raynaud phenomenon of 13 patients disap-peared ,and fever and joint pain were alleviated significantly .ESR reduced from (92 ± 24)mm/h to (27 ± 15)mm/h ,and 24h urinary protein reduced from (8 .12 ± 4 .76)g to (1 .83 ± 1 .55)g .The negative conversion rate of anti-SM antibody and anti-ds-DNA antibody decreased obviously .[Conclusion

  3. EXCHANGE RATE - REGIMES AND POLICIES

    Directory of Open Access Journals (Sweden)

    Novak Lučić

    2014-12-01

    Full Text Available Exchange rate of one currency is the price of the currency expressed in units of other currency. It is formed by the interaction of supply and demand in the foreign exchange market. Given that the exchange rate has a direct impact on the competitiveness of a country in terms of features of its exports and imports, in its balance of payments, and indirectly the overall economic and social development, in addition to acting in market principles - supply and demand in the formation of the equilibrium exchange rate, exchange rate is subject to different, stronger or weaker, more or less, forms of intervention. In the search for the optimal exchange rate policy of the national currency, the monetary authorities are positioned between the two extremes - the complete abandonment of the exchange rate to the market laws of supply and demand, or fixing the exchange rate for any of the selected anchor currency.

  4. Data Exchange Inventory (DEXI) System

    Data.gov (United States)

    Social Security Administration — DEXI is an intranet application used by SSA users to track all incoming and outgoing data exchanges between SSA and our data exchange partners. Information such as...

  5. 血浆置换联合日间连续性血液滤过治疗肝衰竭并肾功能不全的护理%Nursing care of plasma exchange combined with daytime continuous ve-nous-venous hemofiltration in the treatment of liver failure accompanied with renal insufficiency

    Institute of Scientific and Technical Information of China (English)

    李颖; 周莉; 陈占军; 郑素军; 段钟平

    2015-01-01

    Objective To summarize the nursing care of plasma exchange combined with daytime continuous venous-venous hemofiltration in liver failure patients accompanied with renal insufficiency. Methods 187 liver failure patients accompanied with renal insufficiency received plasma exchange combined with daytime continuous venous-venous hemofiltration in Artificial Liver Center, Beijing You'an Hospital Affiliated to Capital Medical University from January 2013 to May 2014 were selected as research objects. Liver and kidney function and blood coagulation indexes before and after treatment were compared. The nursing measures included the pretreatment conversation with patient, close observation, correct handling to adverse reactions with effective nursing intervention during treatment, health education and follow up after treatment. Results Alanine transaminase [(220.2±109.9) v s (366.4±153.3) U/L], aspartate transami-nase [(148.2±71.7) vs (219.8±90.0) U/L], total bilirubin [(283.0±78.2) vs (420.0±106.3)μmol/L], direct bilirubin [(141.5±38.1) vs (206.7±52.4)μmol/L], serum urea [(25.0±5.8) vs (28.8±5.6) mmol/L], creatinine [(176.6±38.6) vs (290.7±63.3)μmol/L] of patient after treatment was significantly lower than that before treatment respectively, albumin [(28.1±3.0) v s (26.6±3.1) g/L], prothrombin activity [(32.3±7.1)%v s (27.7±7.0)%] of patient after treatment was significantly higher than that before treatment respectively, with significantly statistical difference (P﹤ 0.01). Conclusion The combination of plas-ma exchange and daytime continuous venous-venous hemofiltration provides a good option for treatment of liver failure patients accompanied with renal insufficiency. Nurs-ing care support during the whole treatment proce-dures is the key of success.%目的:总结肝衰竭合并肾功能不全患者行血浆置换联合日间连续性血液滤过治疗的护理。方法选取首都医科大学附属北京佑安医院人工肝中心2013年1

  6. plasma treatment

    Directory of Open Access Journals (Sweden)

    Puač Nevena

    2014-11-01

    Full Text Available In this paper we will present results for plasma sterilization of planktonic samples of two reference strains of bacteria, Pseudomonas aeruginosa ATCC 27853 and Enterococcus faecalis ATCC 29212. We have used a plasma needle as a source of non-equilibrium atmospheric plasma in all treatments. This device is already well characterized by OES, derivative probes and mass spectrometry. It was shown that power delivered to the plasma is bellow 2 W and that it produces the main radical oxygen and nitrogen species believed to be responsible for the sterilization process. Here we will only present results obtained by electron paramagnetic resonance which was used to detect the OH, H and NO species. Treatment time and power delivered to the plasma were found to have the strongest influence on sterilization. In all cases we have observed a reduction of several orders of magnitude in the concentration of bacteria and for the longest treatment time complete eradication. A more efficient sterilization was achieved in the case of gram negative bacteria.

  7. Plasma metallization

    CERN Document Server

    Crowther, J M

    1997-01-01

    Many methods are currently used for the production of thin metal films. However, all of these have drawbacks associated with them, for example the need for UHV conditions, high temperatures, exotic metal precursors, or the inability to coat complex shaped objects. Reduction of supported metal salts by non-isothermal plasma treatment does not suffer from these drawbacks. In order to produce and analyse metal films before they become contaminated, a plasma chamber which could be attached directly to a UHV chamber with XPS capability was designed and built. This allowed plasma treatment of supported metal salts and surface analysis by XPS to be performed without exposure of the metal film to the atmosphere. Non-equilibrium plasma treatment of Nylon 66 supported gold(lll) chloride using hydrogen as the feed gas resulted in a 95% pure gold film, the remaining 5% of the film being carbon. If argon or helium were used as the feed gases during plasma treatment the resultant gold films were 100% pure. Some degree of s...

  8. The Exchange Rate Forecasting Puzzle

    OpenAIRE

    Francis Vitek

    2005-01-01

    We survey and update the empirical literature concerning the predictability of nominal exchange rates using structural macroeconomic models over the recent floating exchange rate period. In particular, we consider both flexible and sticky price versions of the monetary model of nominal exchange rate determination. In agreement with the existing empirical literature, we find that nominal exchange rate movements are difficult to forecast, with a random walk generally dominating the monetary mod...

  9. Geology Exchange Program

    Science.gov (United States)

    Because geology professors cannot bring ore deposits from around the globe into their classrooms, the next best thing is to take their students to the deposits, according to David Norman, an associate professor of geochemistry at New Mexico Tech and Angus Moore of the Royal School of Mines. They organized a new exchange program between the New Mexico Institute of Mining and Technology in Socorro, N.M., and the Royal School of Mines in London, England. In May, 14 students from England toured deposits in New Mexico, Arizona, Utah, and Colorado; in the photograph, Norman (on the right) describes a rock from a New Mexico ore deposit to some of the visitors from England. In early June a contingency from New Mexico Tech began studying deposits in England, Spain, and Portugal. Norman and Moore say that the exchange program may be expanded next year.

  10. Lipid exchange by ultracentrifugation

    DEFF Research Database (Denmark)

    Drachmann, Nikolaj Düring; Olesen, Claus

    2014-01-01

    Lipids play an important role in maintaining P-type ATPase structure and function, and often they are crucial for ATPase activity. When the P-type ATPases are in the membrane, they are surrounded by a mix of different lipids species with varying aliphatic chain lengths and saturation......, and the complex interplay between the lipids and the P-type ATPases are still not well understood. We here describe a robust method to exchange the majority of the lipids surrounding the ATPase after solubilisation and/or purification with a target lipid of interest. The method is based on an ultracentrifugation...... step, where the protein sample is spun through a dense buffer containing large excess of the target lipid, which results in an approximately 80-85 % lipid exchange. The method is a very gently technique that maintains protein folding during the process, hence allowing further characterization...

  11. Exchange rate rebounds after foreign exchange market interventions

    Science.gov (United States)

    Hoshikawa, Takeshi

    2017-03-01

    This study examined the rebounds in the exchange rate after foreign exchange intervention. When intervention is strongly effective, the exchange rate rebounds at next day. The effect of intervention is reduced slightly by the rebound after the intervention. The exchange rate might have been 67.12-77.47 yen to a US dollar without yen-selling/dollar-purchasing intervention of 74,691,100 million yen implemented by the Japanese government since 1991, in comparison to the actual exchange rate was 103.19 yen to the US dollar at the end of March 2014.

  12. Heat exchange apparatus

    Science.gov (United States)

    Degtiarenko, Pavel V.

    2003-08-12

    A heat exchange apparatus comprising a coolant conduit or heat sink having attached to its surface a first radial array of spaced-apart parallel plate fins or needles and a second radial array of spaced-apart parallel plate fins or needles thermally coupled to a body to be cooled and meshed with, but not contacting the first radial array of spaced-apart parallel plate fins or needles.

  13. Exchange Rate Predictions

    OpenAIRE

    Yablonskyy, Karen

    2012-01-01

    The aim of this thesis is to analyze the foreign exchange currency forecasting techniques. Moreover the central idea behind the topic is to develop the strategy of forecasting by choosing indicators and techniques to make own forecast on currency pair EUR/USD. This thesis work is a mixture of theory and practice analyses. The goal during the work on this project was to study different types of forecasting techniques and make own forecast, practice forecasting and trading on Forex platform, ba...

  14. Thermoelectric heat exchange element

    Science.gov (United States)

    Callas, James J.; Taher, Mahmoud A.

    2007-08-14

    A thermoelectric heat exchange module includes a first substrate including a heat receptive side and a heat donative side and a series of undulatory pleats. The module may also include a thermoelectric material layer having a ZT value of 1.0 or more disposed on at least one of the heat receptive side and the heat donative side, and an electrical contact may be in electrical communication with the thermoelectric material layer.

  15. Exchange Rate Predictions

    OpenAIRE

    Yablonskyy, Karen

    2012-01-01

    The aim of this thesis is to analyze the foreign exchange currency forecasting techniques. Moreover the central idea behind the topic is to develop the strategy of forecasting by choosing indicators and techniques to make own forecast on currency pair EUR/USD. This thesis work is a mixture of theory and practice analyses. The goal during the work on this project was to study different types of forecasting techniques and make own forecast, practice forecasting and trading on Forex platform, ba...

  16. Hydrogen Exchange Mass Spectrometry.

    Science.gov (United States)

    Mayne, Leland

    2016-01-01

    Hydrogen exchange (HX) methods can reveal much about the structure, energetics, and dynamics of proteins. The addition of mass spectrometry (MS) to an earlier fragmentation-separation HX analysis now extends HX studies to larger proteins at high structural resolution and can provide information not available before. This chapter discusses experimental aspects of HX labeling, especially with respect to the use of MS and the analysis of MS data.

  17. Thermoelectric heat exchange element

    Energy Technology Data Exchange (ETDEWEB)

    Callas, James J. (Peoria, IL); Taher, Mahmoud A. (Peoria, IL)

    2007-08-14

    A thermoelectric heat exchange module includes a first substrate including a heat receptive side and a heat donative side and a series of undulatory pleats. The module may also include a thermoelectric material layer having a ZT value of 1.0 or more disposed on at least one of the heat receptive side and the heat donative side, and an electrical contact may be in electrical communication with the thermoelectric material layer.

  18. On Exchange QB∞-Rings

    Institute of Scientific and Technical Information of China (English)

    Huanyin Chen

    2007-01-01

    In this paper, we introduce a new class of rings, the QB∞-rings. We investigate necessary and sufficient conditions under which an exchange ring is a QB∞-ring. The modules over an exchange QB∞-ring are studied. Also, we prove that every regular square matrix over an exchange QB∞-ring admits a diagonal reduction by pseudo-invertible matrices.

  19. O3 and NOx Exchange

    NARCIS (Netherlands)

    Loubet, B.; Castell, J.F.; Laville, P.; Personne, E.; Tuzet, A.; Ammann, C.; Emberson, L.; Ganzeveld, L.; Kowalski, A.S.; Merbold, L.; Stella, P.; Tuovinen, J.P.

    2015-01-01

    This discussion was based on the background document “Review on modelling atmosphere-biosphere exchange of Ozone and Nitrogen oxides”, which reviews the processes contributing to biosphere-atmosphere exchange of O3 and NOx, including stomatal and non-stomatal exchange of O3 and NO, NO2.

  20. The stability of exchange networks

    NARCIS (Netherlands)

    Doğan, G.; Assen, M. van; Rijt, A. van de; Buskens, V.W.

    2009-01-01

    Economic and sociological exchange theories predict divisions of exchange benefits given an assumed fixed network of exchange relations. Since network structure has been found to have a large impact on actors’ payoffs, actors have strong incentives for network change.Weanswer the question what happe

  1. Timing Foreign Exchange Markets

    Directory of Open Access Journals (Sweden)

    Samuel W. Malone

    2016-03-01

    Full Text Available To improve short-horizon exchange rate forecasts, we employ foreign exchange market risk factors as fundamentals, and Bayesian treed Gaussian process (BTGP models to handle non-linear, time-varying relationships between these fundamentals and exchange rates. Forecasts from the BTGP model conditional on the carry and dollar factors dominate random walk forecasts on accuracy and economic criteria in the Meese-Rogoff setting. Superior market timing ability for large moves, more than directional accuracy, drives the BTGP’s success. We explain how, through a model averaging Monte Carlo scheme, the BTGP is able to simultaneously exploit smoothness and rough breaks in between-variable dynamics. Either feature in isolation is unable to consistently outperform benchmarks throughout the full span of time in our forecasting exercises. Trading strategies based on ex ante BTGP forecasts deliver the highest out-of-sample risk-adjusted returns for the median currency, as well as for both predictable, traded risk factors.

  2. Scraped surface heat exchangers.

    Science.gov (United States)

    Rao, Chetan S; Hartel, Richard W

    2006-01-01

    Scraped surface heat exchangers (SSHEs) are commonly used in the food, chemical, and pharmaceutical industries for heat transfer, crystallization, and other continuous processes. They are ideally suited for products that are viscous, sticky, that contain particulate matter, or that need some degree of crystallization. Since these characteristics describe a vast majority of processed foods, SSHEs are especially suited for pumpable food products. During operation, the product is brought in contact with a heat transfer surface that is rapidly and continuously scraped, thereby exposing the surface to the passage of untreated product. In addition to maintaining high and uniform heat exchange, the scraper blades also provide simultaneous mixing and agitation. Heat exchange for sticky and viscous foods such as heavy salad dressings, margarine, chocolate, peanut butter, fondant, ice cream, and shortenings is possible only by using SSHEs. High heat transfer coefficients are achieved because the boundary layer is continuously replaced by fresh material. Moreover, the product is in contact with the heating surface for only a few seconds and high temperature gradients can be used without the danger of causing undesirable reactions. SSHEs are versatile in the use of heat transfer medium and the various unit operations that can be carried out simultaneously. This article critically reviews the current understanding of the operations and applications of SSHEs.

  3. The exchangeability of shape

    Directory of Open Access Journals (Sweden)

    Kaba Dramane

    2010-10-01

    Full Text Available Abstract Background Landmark based geometric morphometrics (GM allows the quantitative comparison of organismal shapes. When applied to systematics, it is able to score shape changes which often are undetectable by traditional morphological studies and even by classical morphometric approaches. It has thus become a fast and low cost candidate to identify cryptic species. Due to inherent mathematical properties, shape variables derived from one set of coordinates cannot be compared with shape variables derived from another set. Raw coordinates which produce these shape variables could be used for data exchange, however they contain measurement error. The latter may represent a significant obstacle when the objective is to distinguish very similar species. Results We show here that a single user derived dataset produces much less classification error than a multiple one. The question then becomes how to circumvent the lack of exchangeability of shape variables while preserving a single user dataset. A solution to this question could lead to the creation of a relatively fast and inexpensive systematic tool adapted for the recognition of cryptic species. Conclusions To preserve both exchangeability of shape and a single user derived dataset, our suggestion is to create a free access bank of reference images from which one can produce raw coordinates and use them for comparison with external specimens. Thus, we propose an alternative geometric descriptive system that separates 2-D data gathering and analyzes.

  4. Plasma dynamo

    CERN Document Server

    Rincon, F; Schekochihin, A A; Valentini, F

    2015-01-01

    Magnetic fields pervade the entire Universe and, through their dynamical interactions with matter, affect the formation and evolution of astrophysical systems from cosmological to planetary scales. How primordial cosmological seed fields arose and were further amplified to $\\mu$Gauss levels reported in nearby galaxy clusters, near equipartition with kinetic energy of plasma motions and on scales of at least tens of kiloparsecs, is a major theoretical puzzle still largely unconstrained by observations. Extragalactic plasmas are weakly collisional (as opposed to collisional magnetohydrodynamic fluids), and whether magnetic-field growth and its sustainment through an efficient dynamo instability driven by chaotic motions is possible in such plasmas is not known. Fully kinetic numerical simulations of the Vlasov equation in a six-dimensional phase space necessary to answer this question have until recently remained beyond computational capabilities. Here, we show by means of such simulations that magnetic-field a...

  5. Microwave Plasma Production of Metal Nanopowders

    Directory of Open Access Journals (Sweden)

    Joseph Lik Hang Chau

    2014-06-01

    Full Text Available Metal and metal alloy nanopowders were prepared by using the microwave plasma synthesis method. The microwave plasma was operated in atmospheric pressure at a frequency of 2.45 GHz. The precursor decomposed thermally in the plasma reaction region and the products were then condensed in the heat exchanger, were separated from the gas by the powder filter, and then finally collected in the powder collector. The effect of various processing parameters such as plasma gas, carrier gas, cooling gas, precursor raw materials and feeding rate were studied in this work. Cu, Mo, W, Mo-Ni and Fe-Co nanopowders were successfully prepared by using the microwave plasma synthesis method. The processing conditions can be tuned to manipulate the particle size of the nanopowders.

  6. Fundamental aspects of plasma chemical physics transport

    CERN Document Server

    Capitelli, Mario; Laricchiuta, Annarita

    2013-01-01

    Fundamental Aspects of Plasma Chemical Physics: Tranpsort develops basic and advanced concepts of plasma transport to the modern treatment of the Chapman-Enskog method for the solution of the Boltzmann transport equation. The book invites the reader to consider actual problems of the transport of thermal plasmas with particular attention to the derivation of diffusion- and viscosity-type transport cross sections, stressing the role of resonant charge-exchange processes in affecting the diffusion-type collision calculation of viscosity-type collision integrals. A wide range of topics is then discussed including (1) the effect of non-equilibrium vibrational distributions on the transport of vibrational energy, (2) the role of electronically excited states in the transport properties of thermal plasmas, (3) the dependence of transport properties on the multitude of Saha equations for multi-temperature plasmas, and (4) the effect of the magnetic field on transport properties. Throughout the book, worked examples ...

  7. Experimental study on heat exchange of several types of exchangers

    Institute of Scientific and Technical Information of China (English)

    周志华; 赵振华; 于洋

    2009-01-01

    Aiming at the ground-coupled source heat pump that possesses the shortcomings of occupying larger land,this article studies the heat exchanged of heat exchanger in piling,and compares it with common heat exchangers buried directly. The result indicates that the heat exchanger makes the best use of structure of building,saves land,reduces the construction cost,and the heat exchanged is obviously more than exchangers buried directly. In winter condition,when W-shape pipe heat exchanger in pile foundation is 50 m deep and diameter is 800 mm,it transfers 1.2-1.3 times as large as the one of single U-shape buried directly at the flow rate of 0.6 m/s,whose borehole diameter is 300 mm. And in summer condition it does about 2.0-2.3 times as that of U-shape one.

  8. Plasma medicine

    CERN Document Server

    Fridman, Alexander

    2012-01-01

    This comprehensive text is suitable for researchers and graduate students of a 'hot' new topic in medical physics. Written by the world's leading experts,  this book aims to present recent developments in plasma medicine, both technological and scientific, reviewed in a fashion accessible to the highly interdisciplinary audience consisting of doctors, physicists, biologists, chemists and other scientists, university students and professors, engineers and medical practitioners. The book focuses on major topics and covers the physics required to develop novel plasma discharges relevant for medic

  9. Plasma Exchange for Refractory MDA5 Myositis and ILD

    Science.gov (United States)

    2017-04-26

    Sciences Education student and your department has told you they cannot fund your publication, the 59th Clinical Research Division may pay for your basic ...Tri-Service Nursing Research Program (TSNRP): Defense Medical Research & Development Program (DMRDP): NIH; Congressionally Directed Medical Research...before final clearance Is required to publish/present your materials. If you have any questions or concerns. please contact the S9 CRD/Publications and

  10. Dementia Improvement after Plasma Exchange for Familial Hypercholesterolemia

    Directory of Open Access Journals (Sweden)

    Allen J. Orehek

    2016-01-01

    Full Text Available Worldwide dementia related memory issues affect a great number of patients and families. In this case, a “senior moment” was noted at age fifty and issues with memory and mind progressed resulting in early retirement from work. The patient described here was given a diagnosis of “Pre-Alzheimer’s disease” and presented for further accurate evaluation, diagnosis, and management. The medical management resulted in an improvement in the patients memory and cognitive ability.

  11. Real Exchange Rate Targets, Nominal Exchange Rate Policies, and Inflation Real Exchange Rate Targets, Nominal Exchange Rate Policies, and Inflation

    Directory of Open Access Journals (Sweden)

    J. Saúl Lizondo

    1991-03-01

    Full Text Available Real Exchange Rate Targets, Nominal Exchange Rate Policies, and Inflation Thh paper examines the implications of some nominal exchange rate policies aimed or attaining a given real exchange rate target. A policy rule that sets the rate of nominal depreciation as a function of the departures of the real exchange rate from its target level is unable to achieve the target. In contrast, a policv rule that sets the change in the rate of depreciation as a function of those departures may lead the economy to the target, under certain conditions. However, this policy could also lead the economy to a process of accelerating inflation.

  12. Mastering Microsoft Exchange Server 2010

    CERN Document Server

    McBee, Jim

    2010-01-01

    A top-selling guide to Exchange Server-now fully updated for Exchange Server 2010. Keep your Microsoft messaging system up to date and protected with the very newest version, Exchange Server 2010, and this comprehensive guide. Whether you're upgrading from Exchange Server 2007 SP1 or earlier, installing for the first time, or migrating from another system, this step-by-step guide provides the hands-on instruction, practical application, and real-world advice you need.: Explains Microsoft Exchange Server 2010, the latest release of Microsoft's messaging system that protects against spam and vir

  13. Integrated Foreign Exchange Risk Management

    DEFF Research Database (Denmark)

    Aabo, Tom; Høg, Esben; Kuhn, Jochen

    Empirical research has focused on export as a proxy for the exchange rate exposure and the use of foreign exchange derivatives as the instrument to deal with this exposure. This empirical study applies an integrated foreign exchange risk management approach with a particular focus on the role...... of import in medium-sized, manufacturing firms in Denmark (a small, open economy). We find a strong, negative relation between import and foreign exchange derivatives usage on the aggregate level. Our findings are consistent with the notion that firms use import to match the foreign exchange exposure...... created by foreign sales activities....

  14. Integrated Foreign Exchange Risk Management

    DEFF Research Database (Denmark)

    Aabo, Tom; Høg, Esben; Kuhn, Jochen

    Empirical research has focused on export as a proxy for the exchange rate exposure and the use of foreign exchange derivatives as the instrument to deal with this exposure. This empirical study applies an integrated foreign exchange risk management approach with a particular focus on the role...... of import in medium-sized, manufacturing firms in Denmark (a small, open economy). We find a strong, negative relation between import and foreign exchange derivatives usage on the aggregate level. Our findings are consistent with the notion that firms use import to match the foreign exchange exposure...

  15. Plasma physics and engineering

    CERN Document Server

    Fridman, Alexander

    2011-01-01

    Part I: Fundamentals of Plasma Physics and Plasma ChemistryPlasma in Nature, in the Laboratory, and in IndustryOccurrence of Plasma: Natural and Man MadeGas DischargesPlasma Applications, Plasmas in IndustryPlasma Applications for Environmental ControlPlasma Applications in Energy ConversionPlasma Application for Material ProcessingBreakthrough Plasma Applications in Modern TechnologyElementary Processes of Charged Species in PlasmaElementary Charged Particles in Plasma and Their Elastic and Inelastic CollisionsIonization ProcessesMechanisms of Electron Losses: The Electron-Ion RecombinationEl

  16. State Health Facts - State Decisions on Exchanges

    Data.gov (United States)

    U.S. Department of Health & Human Services — State Decisions For Creating Health Insurance Exchanges, including Exchange Decision, Federal Approval Status, Structure of Exchange, and Type of Exchange.

  17. How do we reduce plasma transfusion in Rhode Island?

    Science.gov (United States)

    Nixon, Christian P; Tavares, Maria F; Sweeney, Joseph D

    2017-08-01

    Plasma transfusions are given to patients with coagulopathy, either prophylactically, before an invasive procedure; or therapeutically, in the presence of active bleeding; and as an exchange fluid in therapeutic plasma exchange for disorders such as thrombotic thrombocytopenic purpura. There is consensus that many prophylactic plasma transfusions are non-efficacious, and the misdiagnosis of thrombotic thrombocytopenic purpura results in unnecessary therapeutic plasma exchange. Beginning in 2001, programs to reduce plasma transfusion in the three major teaching hospitals in Rhode Island were initiated. The programs evolved through the establishment of guidelines, education for key prescribers of plasma, screening of plasma prescriptions, and engagement of individual prescribing physicians for out-of-guidelines prescriptions with modification or cancellation. Establishment of an in-house ADAMTS13 (ADAM metallopeptidase with thrombospondin type 1, motif 13) assay in 2013 was used to prevent therapeutic plasma exchange in patients with non-thrombotic thrombocytopenic purpura microangiopathy. Transfusion service data were gathered at the hospital level regarding blood component use, hospital data for discharges, inpatient mortality, and mean case-mix index, and, at the state level, for units of plasma shipped from the community blood center to in-state hospitals. Between 2006 and 2016, a reduction in plasma use from 11,805 to 2677 units (a 77% decrease) was observed in the three hospitals and was mirrored in the state as a whole. This decline was not associated with any increase in red blood cell transfusion. Inpatient mortality either declined or was unchanged. An active program focused on education and interdiction can achieve a large decrease in plasma transfusions without evidence of patient harm. © 2017 AABB.

  18. Small particle heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A.J.

    1978-06-01

    A dispersion of small absorbing particles forms an ideal system to collect radiant energy, transform it to heat, and efficiently transfer the heat to a surrounding fluid. If the heated fluid is a pressurized gas, it can be passed through an expansion turbine to create useful mechanical energy. The most obvious application of this technique is its use in a solar collection system. In this case, the incoming sunlight is used to heat a compressed gas in an engine utilizing a Brayton cycle. The solar collection system may utilize high concentration as provided by a central receiver or parabolic dish, medium concentration from a linear collector, or possibly no concentration using a flat plate collector, if precautions were taken to reduce the heat losses. The same concept may be applied generally to non-solar heat exchangers. These may be of the type used to heat a gas from a combustion source, or in general as a gas to gas heat exchanger. The latter application may be limited to rather high temperature. Each of the above applications is discussed. First, a description of the concept is applied to a solar central-tower system. The general principles are described, including the optical and physical characteristics of the particles, the confinement of the gas-particle mixture, and the system considerations; the latter include the amount and type of particles, the receiver efficiency and the generation of the particles. The same considerations are reviewed for applications to linear trough and flat plate receivers. Finally, the use of small particles in non-solar heat exchangers is considered.

  19. Cryogenic regenerative heat exchangers

    CERN Document Server

    Ackermann, Robert A

    1997-01-01

    An in-depth survey of regenerative heat exchangers, this book chronicles the development and recent commercialization of regenerative devices for cryogenic applications. Chapters cover historical background, concepts, practical applications, design data, and numerical solutions, providing the latest information for engineers to develop advanced cryogenic machines. The discussions include insights into the operation of a regenerator; descriptions of the cyclic and fluid temperature distributions in a regenerator; data for various matrix geometries and materials, including coarse and fine bronze, stainless steel-woven wire mesh screens, and lead spheres; and unique operating features of cryocoolers that produce deviations from ideal regenerator theory.

  20. EDITORIAL: Stochasticity in fusion plasmas Stochasticity in fusion plasmas

    Science.gov (United States)

    Unterberg, Bernhard

    2010-03-01

    Structure formation and transport in stochastic plasmas is a topic of growing importance in many fields of plasma physics from astrophysics to fusion research. In particular, the possibility to control transport in the boundary of confined fusion plasmas by resonant magnetic perturbations has been investigated extensively during recent years. A major research achievement was finding that the intense transient particle and heat fluxes associated with edge localized modes (here type-I ELMs) in magnetically confined fusion plasmas can be mitigated or even suppressed by resonant magnetic perturbation fields. This observation opened up a possible scheme to avoid too large erosion and material damage by such transients in future fusion devices such as ITER. However, it is widely recognized that a more basic understanding is needed to extrapolate the results obtained in present experiments to future fusion devices. The 4th workshop on Stochasticity in Fusion Plasmas was held in Jülich, Germany, from 2 to 4 March 2009. This series of workshops aims at gathering fusion experts from various plasma configurations such as tokamaks, stellarators and reversed field pinches to exchange knowledge on structure formation and transport in stochastic fusion plasmas. The workshops have attracted colleagues from both experiment and theory and stimulated fruitful discussions about the basics of stochastic fusion plasmas. Important papers from the first three workshops in 2003, 2005 and 2007 have been published in previous special issues of Nuclear Fusion (stacks.iop.org/NF/44/i=6, stacks.iop.org/NF/46/i=4 and stacks.iop.org/NF/48/i=2). This special issue comprises contributions presented at the 4th SFP workshop, dealing with the main subjects such as formation of stochastic magnetic layers, energy and particle transport in stochastic magnetic fields, plasma response to external, non-axis-symmetric perturbations and last but not least application of resonant magnetic perturbations for

  1. Magnetoresistive waves in plasmas

    Science.gov (United States)

    Felber, F. S.; Hunter, R. O., Jr.; Pereira, N. R.; Tajima, T.

    1982-10-01

    The self-generated magnetic field of a current diffusing into a plasma between conductors can magnetically insulate the plasma. Propagation of magnetoresistive waves in plasmas is analyzed. Applications to plasma opening switches are discussed.

  2. Real exchange rate fluctuations, endogenous tradability and exchange rate regime

    OpenAIRE

    Kanda Naknoi

    2005-01-01

    This paper, empirically and theoretically, studies variance decomposition of real exchange rate. We find that deviations from the law of one price for traded goods drive most real exchange rates. However, the relative price of nontraded goods is also important for some countries maintaining stable exchange rate. We propose an explanation based on dynamics of comparative advantage. Our model predicts that comovement of terms of trade and productivity differentials of the nontraded and the expo...

  3. Synthesis of Heat Exchanger Network Considering Multipass Exchangers

    Institute of Scientific and Technical Information of China (English)

    李绍军; 姚平经

    2001-01-01

    Many methods have been proposed for synthesis of heat exchanger networks in recent years, most of which consider single pass exchangers. In this study some evolutionary rules have been proposed for synthesis of multipass exchanger networks. The method is based on the heuristic that optimal networks should feature maximum energy recovery and have the minimum number of shells. The effectiveness of the developed evolutionary rules is demonstrated through some literature examples.

  4. Capital Flows, Exchange Rate Flexibility, and the Real Exchange Rate

    OpenAIRE

    Jean-Louis Combes; Patrick Plane; Tidiane Kinda

    2011-01-01

    This paper analyzes the impact of capital inflows and exchange rate flexibility on the real exchange rate in developing countries based on panel cointegration techniques. The results show that public and private flows are associated with a real exchange rate appreciation. Among private flows, portfolio investment has the highest appreciation effect-almost seven times that of foreign direct investment or bank loans-and private transfers have the lowest effect. Using a de facto measure of excha...

  5. Interfacing heat exchanger network synthesis and detailed heat exchanger design

    Energy Technology Data Exchange (ETDEWEB)

    Polley, G.T.; Panjeh Shahi, M.H. (Manchester Univ. (United Kingdom). Inst. of Science and Technology)

    1991-11-01

    Current heat exchanger network synthesis targeting and design procedures involve the use of assumed stream heat transfer coefficients. However, during detailed heat exchanger design, allowable pressure drops are often the most critical factors. The result can be big differences between the exchanger sizes and costs anticipated by the network designer and those realised by the exchanger designer. This in turn prejudices any optimisation attempted at the network design stage. In this paper it is shown how allowable pressure drop can be used as a basis of network design and consistency between expectation and realisation achieved. (author).

  6. Electrosurgical plasmas

    Science.gov (United States)

    Stalder, Kenneth R.; McMillen, Donald F.; Woloszko, Jean

    2005-06-01

    Electrosurgical medical devices based on repetitively pulsed nonequilibrium micron-scale to millimetre-scale plasma discharges in saline solutions are described. The formation of vapour layers (bubbles) around active electrodes appears to be a common feature at moderate (<300 V rms) voltages, and dissociation, excitation and ionization of the vapour in these bubbles produces chemical conditions that are thought to be the source of beneficial tissue removal and treatment. Experimental data are discussed, as are the results of modelling efforts of the plasma chemistry. Hydroxyl radicals, hydrogen atoms and other species are observed spectroscopically and their interactions with collagen, a common component of tissue encountered in surgical situations, are considered. Several pathways by which hydroxyl radicals interacting with collagen can lead to tissue removal are discussed.

  7. Electrosurgical plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Stalder, Kenneth R; McMillen, Donald F; Woloszko, Jean [ArthroCare Corp., Sunnyvale, CA 94085-3523 (United States)

    2005-06-07

    Electrosurgical medical devices based on repetitively pulsed nonequilibrium micron-scale to millimetre-scale plasma discharges in saline solutions are described. The formation of vapour layers (bubbles) around active electrodes appears to be a common feature at moderate (<300 V rms) voltages, and dissociation, excitation and ionization of the vapour in these bubbles produces chemical conditions that are thought to be the source of beneficial tissue removal and treatment. Experimental data are discussed, as are the results of modelling efforts of the plasma chemistry. Hydroxyl radicals, hydrogen atoms and other species are observed spectroscopically and their interactions with collagen, a common component of tissue encountered in surgical situations, are considered. Several pathways by which hydroxyl radicals interacting with collagen can lead to tissue removal are discussed.

  8. Determination of gold,platinum and palladium in geological samples by inductively coupled plasma mass spectrometry after concentration with 717 anion exchange resin%717阴离子交换树脂富集-电感耦合等离子体质谱法测定地质样品中痕量金铂钯

    Institute of Scientific and Technical Information of China (English)

    李丹; 王锝; 李彪

    2011-01-01

    The adsorption property and separation conditions of 717 anion exchange resin to trace gold,platinum and palladium in geological samples were studied. The sample was dissolved with HCl+ aqua regia under heating in water bath. Only Mo in dissolved elements had interference with the determination of Pd, which could be eliminated using mathematical formula correction. When the flow rate of eluent was 2 mL/min, the enrichment effects of gold, platinum and palladium in 5 % HCl medium reached its best, and the recoveries were close to 100 %. After correcting the influence of coexisting ions, the national first-class certified reference materials were determined by inductively coupled plasma mass spectrometry, and the difference between determination results and certified values was satisfactory. The detection limit of method were 0. 6 ng/mL, 0. 5 ng/mL and 0. 7 ng/mL for Pd, Pt and Au, respectively. Five random geological samples were analyzed by this method in comparison with NiS fire assay-ICP-MS method. The determination results were consistent. The results of two methods were checked by double sample's variance F test, and there was no significant difference.%研究了717型阴离子交换树脂对地质样品中痕量金、铂、钯的吸附性能及分离条件.采用水浴加热,HCl+王水的方式溶解样品,溶出的干扰元素只有Mo对Pd的测定造成干扰,采用数学公式校正可消除此干扰.在5%的HCl介质中,洗脱剂流速为2 mL/min时,金、铂、钯的富集效果最佳,回收率接近100%.经对共存离子影响的校正,用电感耦合等离子体质谱法测定国家一级标准物质,其结果较认定值不超差.方法检出限为Pd 0.6 ng/mL,Pt 0.5ng/mL,Au 0.7ng/mL.随机选取5个地质样品用本法进行分析,同时与硫镍试金-ICP-MS法进行比较,结果一致.两组结果经双样本方差F检验,无显著性差异.

  9. Plasma physics

    CERN Document Server

    Cairns, R A

    1985-01-01

    This book is intended as an introduction to plasma physics at a level suitable for advanced undergraduates or beginning postgraduate students in physics, applied mathematics or astrophysics. The main prerequisite is a knowledge of electromagnetism and of the associated mathematics of vector calculus. SI units are used throughout. There is still a tendency amongst some plasma physics researchers to· cling to C.g.S. units, but it is the author's view that universal adoption of SI units, which have been the internationally agreed standard since 1960, is to be encouraged. After a short introductory chapter, the basic properties of a plasma con­ cerning particle orbits, fluid theory, Coulomb collisions and waves are set out in Chapters 2-5, with illustrations drawn from problems in nuclear fusion research and space physics. The emphasis is on the essential physics involved and (he theoretical and mathematical approach has been kept as simple and intuitive as possible. An attempt has been made to draw attention t...

  10. Plasma pharmacy - physical plasma in pharmaceutical applications.

    Science.gov (United States)

    von Woedtke, Th; Haertel, B; Weltmann, K-D; Lindequist, U

    2013-07-01

    During the last years the use of physical plasma for medical applications has grown rapidly. A multitude of findings about plasma-cell and plasma-tissue interactions and its possible use in therapy have been provided. One of the key findings of plasma medical basic research is that several biological effects do not result from direct plasma-cell or plasma-tissue interaction but are mediated by liquids. Above all, it was demonstrated that simple liquids like water or physiological saline, are antimicrobially active after treatment by atmospheric pressure plasma and that these effects are attributable to the generation of different low-molecular reactive species. Besides, it could be shown that plasma treatment leads to the stimulation of specific aspects of cell metabolism and to a transient and reversible increase of diffusion properties of biological barriers. All these results gave rise to think about another new and innovative field of medical plasma application. In contrast to plasma medicine, which means the direct use of plasmas on or in the living organism for direct therapeutic purposes, this field - as a specific field of medical plasma application - is called plasma pharmacy. Based on the present state of knowledge, most promising application fields of plasma pharmacy might be: plasma-based generation of biologically active liquids; plasma-based preparation, optimization, or stabilization of - mainly liquid - pharmaceutical preparations; support of drug transport across biological barriers; plasma-based stimulation of biotechnological processes.

  11. Fixed Exchange Rates and Trade

    OpenAIRE

    Michael W. Klein; Jay C. Shambaugh

    2004-01-01

    A classic argument for a fixed exchange rate is its promotion of trade. Empirical support for this, however, is mixed. While one branch of research consistently shows a small negative effect of exchange rate volatility on trade, another, more recent, branch presents evidence of a large positive impact of currency unions on trade. This paper helps resolve this disconnect. Our results, which use a new data-based classification of fixed exchange rate regimes, show a large, significant effect of ...

  12. Developing bulk exchange spring magnets

    Energy Technology Data Exchange (ETDEWEB)

    Mccall, Scott K.; Kuntz, Joshua D.

    2017-06-27

    A method of making a bulk exchange spring magnet by providing a magnetically soft material, providing a hard magnetic material, and producing a composite of said magnetically soft material and said hard magnetic material to make the bulk exchange spring magnet. The step of producing a composite of magnetically soft material and hard magnetic material is accomplished by electrophoretic deposition of the magnetically soft material and the hard magnetic material to make the bulk exchange spring magnet.

  13. Exchange Rates, Innovations and Forecasting

    OpenAIRE

    Wolff, Christian C

    1987-01-01

    In this paper an ex-post forecasting experiment is performed on the basis of a version of the "news" model of exchange rate determination. A general finding is that the "news" formulation of monetary exchange rate models leads to relatively accurate ex post exchange rate forecasts. Often the results compare favourably with those obtained from the naive random walk forecasting rule. Thus, the evidence presented in this paper supports the argument that the 1983 finding by Meese and Rogoff (that...

  14. QDB: Validated Plasma Chemistries Database

    Science.gov (United States)

    Rahimi, Sara; Hamilton, James; Hill, Christian; Tennyson, Jonathan; UCL Team

    2016-09-01

    One of most challenging recurring problems when modelling plasmas is the lack of data. This lack of complete and validated datasets hinders research on plasma processes and curbs development of industrial Applications. We will describe the QDB project which aims to fill this missing link by provide a platform for exchange and validation of chemistry datasets. The database will collate published data on both electron scattering and heavy particle reactions and also facilitates and encourages peer-to-peer data sharing by its users. This data platform is rigorously supported by the validation methodical validation of the datasetsan automated chemistry generator employed; this methodology identifies missing reactions in chemistries which although important are currently unreported in the literature and employs mathematical methods to analyze the importance of these chemistries. Gaps in the datasets are filled using in house theoretical methods.

  15. Theoretical investigation of exchange bias

    Institute of Scientific and Technical Information of China (English)

    Xiong Zhi-Jie; Wang Huai-Yu; Ding Ze-Jun

    2007-01-01

    The exchange bias of bilayer magnetic films consisting of ferromagnetic (FM) and antiferromagnetic (AFM) layers in an uncompensated case is studied by use of the many-body Green's function method of quantum statistical theory.The effects of the layer thickness and temperature and the interfacial coupling strength on the exchange bias HE are investigated. The dependence of the exchange bias HE on the FM layer thickness and temperature is qualitatively in agreement with experimental results. When temperature varies, both the coercivity HC and HE decrease with the temperature increasing. For each FM thickness, there exists a least AFM thickness in which the exchange bias occurs,which is called pinning thickness.

  16. Mastering Microsoft Exchange Server 2013

    CERN Document Server

    Elfassy, David

    2013-01-01

    The bestselling guide to Exchange Server, fully updated for the newest version Microsoft Exchange Server 2013 is touted as a solution for lowering the total cost of ownership, whether deployed on-premises or in the cloud. Like the earlier editions, this comprehensive guide covers every aspect of installing, configuring, and managing this multifaceted collaboration system. It offers Windows systems administrators and consultants a complete tutorial and reference, ideal for anyone installing Exchange Server for the first time or those migrating from an earlier Exchange Server version.Microsoft

  17. Data Exchange in Grid Workflow

    Institute of Scientific and Technical Information of China (English)

    ZENG Hongwei; MIAO Huaikou

    2006-01-01

    In existing web services-based workflow, data exchanging across the web services is centralized, the workflow engine intermediates at each step of the application sequence.However, many grid applications, especially data intensive scientific applications, require exchanging large amount of data across the grid services.Having a central workfiow engine relay the data between the services would results in a bottleneck in these cases.This paper proposes a data exchange model for individual grid workflow and multiworkflows composition respectively.The model enables direct communication for large amounts of data between two grid services.To enable data to exchange among multiple workflows, the bridge data service is used.

  18. Quantum dust magnetosonic waves with spin and exchange correlation effects

    Energy Technology Data Exchange (ETDEWEB)

    Maroof, R.; Qamar, A. [Department of Physics, University of Peshawar, Peshawar 25000 (Pakistan); Mushtaq, A. [Department of Physics, Abdul Wali Khan University, Mardan 23200 (Pakistan); National Center for Physics, Shahdra Valley Road, Islamabad 44000 (Pakistan)

    2016-01-15

    Dust magnetosonic waves are studied in degenerate dusty plasmas with spin and exchange correlation effects. Using the fluid equations of magnetoplasma with quantum corrections due to the Bohm potential, temperature degeneracy, spin magnetization energy, and exchange correlation, a generalized dispersion relation is derived. Spin effects are incorporated via spin force and macroscopic spin magnetization current. The exchange-correlation potentials are used, based on the adiabatic local-density approximation, and can be described as a function of the electron density. For three different values of angle, the dispersion relation is reduced to three different modes under the low frequency magnetohydrodynamic assumptions. It is found that the effects of quantum corrections in the presence of dust concentration significantly modify the dispersive properties of these modes. The results are useful for understanding numerous collective phenomena in quantum plasmas, such as those in compact astrophysical objects (e.g., the cores of white dwarf stars and giant planets) and in plasma-assisted nanotechnology (e.g., quantum diodes, quantum free-electron lasers, etc.)

  19. Plasma Medicine: Current Achievements and Future Prospects

    Science.gov (United States)

    Laroussi, Mounir

    2012-10-01

    Research on the biomedical applications of low temperature plasmas started with small scale experiments that were simply aimed at discovering what happens to biological cells when exposed to the chemically rich environment of plasma. These early experiments took place in the mid to late 1990s. As interest in this multidisciplinary field dramatically rose, various engineering and physics groups collaborated with biologists and medical experts to investigate the use of plasma technology as a basis for innovative medical approaches to cure various diseases. However, many questions concerning the fundamental mechanisms involved in cell-plasma interaction remained unanswered. As a result various workshops were organized to gather the diverse research community in the field of plasma medicine in order to have a fruitful exchange of ideas regarding the scientific challenges that needed to be surmounted to advance and expand the field's knowledge base. The present GEC workshop continues this important tradition of scientific cooperation since there is still a significant lack of understanding of many of the biochemical and molecular pathways that come into play when biological cells are exposed to plasmas. In this talk, first background information on the various plasma devices developed in our institute will be presented. This will be followed by a summary of our work on the effects of plasmas on prokaryotic and eukaryotic cells. The talk will be concluded by presenting our vision of the future of the field and an outline of the main challenges that need to be overcome if practical medical applications are to be achieved.

  20. The Radioecology Exchange

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, Catherine L.; Beresford, Nicholas A.; Patel, Sabera; Wells, Claire; Howard, Brenda J. [NERC Centre for Ecology and Hydrology, CEH Lancaster, Lancaster Environment Centre, Library Av., Bailrigg, Lancaster, LA1 4AP (United Kingdom); Mora, Juan Carlos; Real, Almudena [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT), Avenida complutense 22, Madrid, 28040 (Spain); Beaugelin-Seiller, Karine; Gilbin, Rodolphe; Hinton, Thomas [IRSN-Institut de Radioprotection et de Surete Nucleaire, 31, Avenue de la Division Leclerc, 92260 Fontenay-Aux-Roses (France); Vesterbacka, Pia; Muikku, Maarit; Outola, Iisa [Radiation and Nuclear Safety Authority, P.O. Box 14, FI-00881 Helsinki (Finland); Skuterud, Lavrans; AlbumYtre-Eide, Martin [Norwegian Radiation Protection Authority, Grini Naeringspark 13, Oesteraas, 1332 (Norway); Bradshaw, Clare; Stark, Karolina; Jaeschke, Ben [Stockholms Universitet, Universitetsvaegen 10, Stockholm, 10691 (Sweden); Oughton, Deborah; Skipperud, Lindis [NMBU Norwegian University of Life Science P.O. Box 5003N-1432 Aas, Oslo (Norway); Vandenhove, Hildegarde; Vanhoudt, Nathalie [SCK.CEN, Studiecentrum voor Kernenergie/Centre d' Etude de l' Energie Nucleaire, Avenue Herrmann-Debroux 40, BE-1160 Brussels (Belgium); Willrodt, Christine; Steiner, Martin [Bundesamt fuer Strahlenschutz, Willy-Brandt-Strasse 5, 38226 Salzgitter (Germany)

    2014-07-01

    The Radioecology Exchange (www.radioecology-exchange.org) was created in 2011 under the EU FP7 STAR (Strategy for Allied Radioecology) network of excellence. The project aims to integrate the research efforts on radioecology of nine European organisations into a sustainable network. The web site (together with associated Twitter feeds and Facebook page) currently provides the gateway to project outputs and other on-line radiation protection and radioecological resources. In 2013, the EU FP7 COMET (Coordination and implementation of a pan-European instrument for radioecology) project commenced; it aims to strengthen research on the impact of radiation on man and the environment. COMET includes the STAR partners with the addition of one Japanese and two Ukrainian research institutes. As STAR and COMET interact closely together and with the European Radioecology Alliance (www.er-alliance.org/), the Radioecology Exchange will be modified to become an international 'hub' for information related to radioecology. Project specific information will be hosted on separate web sites www.star-radioecology.org and www.comet-radioecology.org. This paper will present an overview of the resources hosted on the Radioecology Exchange inviting other scientists to contribute. Highlighted aspects of the site include: Social media (News blog, Twitter, Facebook) - Items announcing project outputs, training courses, jobs, studentships etc. Virtual laboratory - Information which encourages integration through joint research and integrated use of data and sample materials. These pages will focus on three categories: (1) Methodological: descriptions and video clips of commonly used analytical methods and protocols and the procedures used in STAR and COMET; (2) Informative: databases made available by STAR/COMET partners together with details of sample archives held. Fact-sheets on radio-ecologically important radionuclides and 'topical descriptions' which show absorbed

  1. Asymmetric exchange in flocks

    CERN Document Server

    Dadhichi, Lokrshi Prawar; Maitra, Ananyo; Ramaswamy, Sriram

    2016-01-01

    As the constituents of a flock are polar, one expects a fore-aft asymmetry in their interactions. We show here that the resulting antisymmetric part of the "exchange coupling" between a bird and its neighbours, if large enough, destabilizes the flock through spontaneous turning of the birds. The same asymmetry also yields a natural mechanism for a difference between the speed of advection of information along the flock and the speed of the flock itself. We show that the absence of detailed balance, and not merely the breaking of Galilean invariance, is responsible for this difference. We delineate the conditions on parameters and wavenumber for the existence of the turning instability. Lastly we present an alternative perspective based on flow-alignment effects in an active liquid crystal with turning inertia in contact with a momentum sink.

  2. Hybrid Heat Exchangers

    Science.gov (United States)

    Tu, Jianping Gene; Shih, Wei

    2010-01-01

    A hybrid light-weight heat exchanger concept has been developed that uses high-conductivity carbon-carbon (C-C) composites as the heat-transfer fins and uses conventional high-temperature metals, such as Inconel, nickel, and titanium as the parting sheets to meet leakage and structural requirements. In order to maximize thermal conductivity, the majority of carbon fiber is aligned in the fin direction resulting in 300 W/m.K or higher conductivity in the fin directions. As a result of this fiber orientation, the coefficient of thermal expansion (CTE) of the C-C composite in both non-fiber directions matches well with the CTE of various high-temperature metal alloys. This allows the joining of fins and parting sheets by using high-temperature braze alloys.

  3. Modeling the Enceladus plume--plasma interaction

    CERN Document Server

    Fleshman, B L; Bagenal, F

    2010-01-01

    We investigate the chemical interaction between Saturn's corotating plasma and Enceladus' volcanic plumes. We evolve plasma as it passes through a prescribed H2O plume using a physical chemistry model adapted for water-group reactions. The flow field is assumed to be that of a plasma around an electrically-conducting obstacle centered on Enceladus and aligned with Saturn's magnetic field, consistent with Cassini magnetometer data. We explore the effects on the physical chemistry due to: (1) a small population of hot electrons; (2) a plasma flow decelerated in response to the pickup of fresh ions; (3) the source rate of neutral H2O. The model confirms that charge exchange dominates the local chemistry and that H3O+ dominates the water-group composition downstream of the Enceladus plumes. We also find that the amount of fresh pickup ions depends heavily on both the neutral source strength and on the presence of a persistent population of hot electrons.

  4. Production of antihydrogen via double charge exchange

    Energy Technology Data Exchange (ETDEWEB)

    Muellers, Andreas

    2013-02-01

    combined Penning Ioffe trap and a new laser system. The goal of this thesis was to implement the double charge-exchange method in this new apparatus and increase the number of antihydrogen atoms produced. Compared to our previous experiment, we could raise the numbers of positronium and antihydrogen atoms produced by two orders of magnitude. Most of this gain is due to the larger positron and antiproton plasmas available by now, but we could also achieve significant improvements in the efficiencies of the individual steps. We therefore showed that the double charge-exchange can produce comparable numbers of antihydrogen as the TBR method, but the fraction of cold, trappable atoms is expected to be much higher. Therefore this work is an important step towards precision measurements with trapped antihydrogen atoms.

  5. Determination of soil organic phosphorus exchange sensitivity

    Science.gov (United States)

    Shand, Charles; Wendler, Renate; Lumsdon, David; Cooper, Pat; George, Timothy; Brown, Lawrie; Giles, Courtney; Stutter, Marc; Menezes-Blackburn, Daniel; Zhang, Hao; Wearing, Catherine; Haygarth, Philip; Blackwell, Martin; Darch, Tegan

    2015-04-01

    Soils contain both organic and inorganic phosphorus (P) species in varying proportions. Studies have shown that many soils contain substantial amounts of inositol hexaphosphate (IHP) and there is much interest worldwide in developing strategies to make some use of this recalcitrant resource for plant growth to reduce P fertilizer inputs. Little is known about the preference of ion exchange processes in the solubilisation of organic vs inorganic P forms in soils, an important first step in making P forms bioavailable. Although they do not possess biotic functions, resins provides a simple means to deplete P forms in soil allowing investigation of exchange selectivity between inorganic and organic P forms. The aim of our work was to determine new understanding of exchange selectivity in soils and provide insight into potential depletion and plant uptake of soil phosphorus, with emphasis on organic forms such as IHP. For our study we used a Cambisol sampled from an agricultural area (Tayport) near Dundee in Scotland. The soil had a high Olsen (0.5 M sodium bicarbonate at pH 8.5) extractable P status (84 mg P/kg) and P-31 nuclear magnetic resonance analysis of its NaOH/EDTA extract showed it contained a substantial proportion of IHP (21 % of total extractable P). For resin extraction we used anion exchange resin sheets (4.17 cm each side) in bicarbonate form to minimise pH related solubilisation effects. We used 3.5 g of soil in 75 ml of water and added 1, 2 or 3 resin squares. After equilibration the resin squares were removed and replaced with fresh resin squares a further 3 times. Phosphorus was recovered from the resin sheets by elution with 0.25 M sulphuric acid and analysed by inductively coupled plasma spectroscopy to determine total P, and colorimetrically with malachite green to determine inorganic P with the remainder assigned to organic P. The data showed that the resin preferentially removed inorganic P and even after four sequential extractions little or

  6. Liquid/liquid heat exchanger

    Science.gov (United States)

    Miller, C. G.

    1980-01-01

    Conceptual design for heat exchanger, utilizing two immiscible liquids with dissimilar specific gravities in direct contact, is more efficient mechanism of heat transfer than conventional heat exchangers with walls or membranes. Concept could be adapted for collection of heat from solar or geothermal sources.

  7. Educators Exchange: A Program Evaluation.

    Science.gov (United States)

    Armstrong, William B.

    The Educators Exchange Program (EEP) was established under a training and educational exchange agreement reached by California's San Diego Community College District (SDCCD) and the republic of Mexico. In the program, the District provided a 4-week technological training program to faculty at Centros de Capacitacion Tecnologica Industrial…

  8. Macroreticular chelating ion-exchangers.

    Science.gov (United States)

    Hirsch, R F; E Gancher, R; Russo, F R

    1970-06-01

    Two macroreticular chelating ion-exchangers have been prepared and characterized. One contains the iminodiacetate group and the second contains the arsonate group as the ion-exchanging site. The macroreticular resins show selectivities among metal ions similar to those of the commercially available naicroreticular chelating resins. Chromatographie separations on the new resins are rapid and sharp.

  9. Social exchange : Relations and networks

    NARCIS (Netherlands)

    Dijkstra, Jacob

    2015-01-01

    In this short paper, I review the literature on social exchange networks, with specific attention to theoretical and experimental research. I indicate how social exchange theory is rooted in general social theory and mention a few of its main links to social network analysis and empirical network re

  10. Exchange Rates and Old People.

    Science.gov (United States)

    Dowd, James J.

    1980-01-01

    Extends earlier work on aging as a process of exchange by focusing on the issue of exchange rates and how they are negotiated. Access to power resources declines with age, placing the old person in the position of negotiating from weakness. (Author)

  11. Value Appropriation in Business Exchange

    DEFF Research Database (Denmark)

    Ellegaard, Chris; Medlin, Christopher J.; Geersbro, Jens

    2014-01-01

    Purpose – Value appropriation is a central, yet neglected aspect in business exchange research. The purpose of the paper is to generate an overview of research on active value appropriation in business exchange and provide the foundation for further research into value appropriation, as well as s...

  12. EXCHANGE. Volume 9-92

    Energy Technology Data Exchange (ETDEWEB)

    Boltz, J.C. [ed.

    1992-09-01

    EXCHANGE is published monthly by the Idaho National Engineering Laboratory (INEL), a multidisciplinary facility operated for the US Department of Energy (DOE). The purpose of EXCHANGE is to inform computer users about about recent changes and innovations in both the mainframe and personal computer environments and how these changes can affect work being performed at DOE facilities.

  13. DN interaction from meson exchange

    NARCIS (Netherlands)

    Haidenbauer, J.; Krein, G.; Meiner, U. -G.; Tolos, L.

    A model of the DN interaction is presented which is developed in close analogy to the meson-exchange (K) over barN potential of the Julich group utilizing SU(4) symmetry constraints. The main ingredients of the interaction are provided by vector meson (rho, omega) exchange and higher-order box

  14. Next Generation Microchannel Heat Exchangers

    CERN Document Server

    Ohadi, Michael; Dessiatoun, Serguei; Cetegen, Edvin

    2013-01-01

    In Next Generation Microchannel Heat Exchangers, the authors’ focus on the new generation highly efficient heat exchangers and presentation of novel data and technical expertise not available in the open literature.  Next generation micro channels offer record high heat transfer coefficients with pressure drops much less than conventional micro channel heat exchangers. These inherent features promise fast penetration into many mew markets, including high heat flux cooling of electronics, waste heat recovery and energy efficiency enhancement applications, alternative energy systems, as well as applications in mass exchangers and chemical reactor systems. The combination of up to the minute research findings and technical know-how make this book very timely as the search for high performance heat and mass exchangers that can cut costs in materials consumption intensifies.

  15. Heat exchanger leakage problem location

    Directory of Open Access Journals (Sweden)

    Jícha Miroslav

    2012-04-01

    Full Text Available Recent compact heat exchangers are very often assembled from numerous parts joined together to separate heat transfer fluids and to form the required heat exchanger arrangement. Therefore, the leak tightness is very important property of the compact heat exchangers. Although, the compact heat exchangers have been produced for many years, there are still technological problems associated with manufacturing of the ideal connection between the individual parts, mainly encountered with special purpose heat exchangers, e.g. gas turbine recuperators. This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine recuperator. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.

  16. High Temperature Heat Exchanger Project

    Energy Technology Data Exchange (ETDEWEB)

    Anthony E. Hechanova, Ph.D.

    2008-09-30

    The UNLV Research Foundation assembled a research consortium for high temperature heat exchanger design and materials compatibility and performance comprised of university and private industry partners under the auspices of the US DOE-NE Nuclear Hydrogen Initiative in October 2003. The objectives of the consortium were to conduct investigations of candidate materials for high temperature heat exchanger componets in hydrogen production processes and design and perform prototypical testing of heat exchangers. The initial research of the consortium focused on the intermediate heat exchanger (located between the nuclear reactor and hydrogen production plan) and the components for the hydrogen iodine decomposition process and sulfuric acid decomposition process. These heat exchanger components were deemed the most challenging from a materials performance and compatibility perspective

  17. Heat exchanger leakage problem location

    Science.gov (United States)

    Hejčík, Jiří; Jícha, Miroslav

    2012-04-01

    Recent compact heat exchangers are very often assembled from numerous parts joined together to separate heat transfer fluids and to form the required heat exchanger arrangement. Therefore, the leak tightness is very important property of the compact heat exchangers. Although, the compact heat exchangers have been produced for many years, there are still technological problems associated with manufacturing of the ideal connection between the individual parts, mainly encountered with special purpose heat exchangers, e.g. gas turbine recuperators. This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine recuperator. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.

  18. Improved edge charge exchange recombination spectroscopy in DIII-D

    Science.gov (United States)

    Chrystal, C.; Burrell, K. H.; Grierson, B. A.; Haskey, S. R.; Groebner, R. J.; Kaplan, D. H.; Briesemeister, A.

    2016-11-01

    The charge exchange recombination spectroscopy diagnostic on the DIII-D tokamak has been upgraded with the addition of more high radial resolution view chords near the edge of the plasma (r/a > 0.8). The additional views are diagnosed with the same number of spectrometers by placing fiber optics side-by-side at the spectrometer entrance with a precise separation that avoids wavelength shifted crosstalk without the use of bandpass filters. The new views improve measurement of edge impurity parameters in steep gradient, H-mode plasmas with many different shapes. The number of edge view chords with 8 mm radial separation has increased from 16 to 38. New fused silica fibers have improved light throughput and clarify the observation of non-Gaussian spectra that suggest the ion distribution function can be non-Maxwellian in low collisionality plasmas.

  19. Fault-Tolerant Heat Exchanger

    Science.gov (United States)

    Izenson, Michael G.; Crowley, Christopher J.

    2005-01-01

    A compact, lightweight heat exchanger has been designed to be fault-tolerant in the sense that a single-point leak would not cause mixing of heat-transfer fluids. This particular heat exchanger is intended to be part of the temperature-regulation system for habitable modules of the International Space Station and to function with water and ammonia as the heat-transfer fluids. The basic fault-tolerant design is adaptable to other heat-transfer fluids and heat exchangers for applications in which mixing of heat-transfer fluids would pose toxic, explosive, or other hazards: Examples could include fuel/air heat exchangers for thermal management on aircraft, process heat exchangers in the cryogenic industry, and heat exchangers used in chemical processing. The reason this heat exchanger can tolerate a single-point leak is that the heat-transfer fluids are everywhere separated by a vented volume and at least two seals. The combination of fault tolerance, compactness, and light weight is implemented in a unique heat-exchanger core configuration: Each fluid passage is entirely surrounded by a vented region bridged by solid structures through which heat is conducted between the fluids. Precise, proprietary fabrication techniques make it possible to manufacture the vented regions and heat-conducting structures with very small dimensions to obtain a very large coefficient of heat transfer between the two fluids. A large heat-transfer coefficient favors compact design by making it possible to use a relatively small core for a given heat-transfer rate. Calculations and experiments have shown that in most respects, the fault-tolerant heat exchanger can be expected to equal or exceed the performance of the non-fault-tolerant heat exchanger that it is intended to supplant (see table). The only significant disadvantages are a slight weight penalty and a small decrease in the mass-specific heat transfer.

  20. PIC Simulation of plasma detachment

    Science.gov (United States)

    Ishiguro, Seiji; Pianpanit, Theerasarn; Hasegawa, Hiroki; Kanno, Ryutaro

    2014-10-01

    The detached plasma, which is caused by gas puffing, has been proposed and it is the most promising way to reduce the heat load to the divertor plate of fusion oriented devices. Dynamical and kinetic behavior of the detached plasma is unresolved. So we are developing particle-in-cell simulation model with atomic processes such as line radiation, ionization, charge-exchange collision and recombination. As a first step, we have performed PIC simulation with Monte Carlo collisions, where spatial and velocity space distributions of charged particles, self-consistent electric field, and atomic processes such as ionization and charge exchange are included. Temperature decrease and density increase in front of the target is observed and electric potential structure along the axis is created. This work is performed with the support and under the auspices of NIFS Collaboration Research programs (NIFS14KNXN279 and 8 NIFS13KNSS038) and the Research Cooperation Program on Hierarchy and Holism in Natural Sciences at the NINS.

  1. Electrically switched ion exchange

    Energy Technology Data Exchange (ETDEWEB)

    Lilga, M.A. [Pacific Northwest National Lab., Richland, WA (United States); Schwartz, D.T.; Genders, D.

    1997-10-01

    A variety of waste types containing radioactive {sup 137}Cs are found throughout the DOE complex. These waste types include water in reactor cooling basins, radioactive high-level waste (HLW) in underground storage tanks, and groundwater. Safety and regulatory requirements and economics require the removal of radiocesium before these wastes can be permanently disposed of. Electrically Switched Ion Exchange (ESIX) is an approach for radioactive cesium separation that combines IX and electrochemistry to provide a selective, reversible, and economic separation method that also produces little or no secondary waste. In the ESIX process, an electroactive IX film is deposited electrochemically onto a high-surface area electrode, and ion uptake and elution are controlled directly by modulating the potential of the film. For cesium, the electroactive films under investigation are ferrocyanides, which are well known to have high selectivities for cesium in concentrated sodium solutions. When a cathode potential is applied to the film, Fe{sup +3} is reduced to the Fe{sup +2} state, and a cation must be intercalated into the film to maintain charge neutrality (i.e., Cs{sup +} is loaded). Conversely, if an anodic potential is applied, a cation must be released from the film (i.e., Cs{sup +} is unloaded). Therefore, to load the film with cesium, the film is simply reduced; to unload cesium, the film is oxidized.

  2. Energy-Exchange Project

    Energy Technology Data Exchange (ETDEWEB)

    1982-04-01

    The purpose of the study was to determine what energy savings can be achieved by coordinating the resources and requirements of two facilities, the 26th Ward Water Pollution Control Plant (WPCP) and a housing development named Starrett City with its own total energy system. It was determined that three energy exchange options were economically and technically feasible. These include: the transfer of digester gas produced at the 26th Ward to the boilers at the Starrett City's total energy plant (TEP); the transfer of hot water heated at the TEP to the 26th Ward for space and process heating; and the transfer of coal effluent waste water from the 26th Ward to the condenser cooling systems at the TEP. Technical information is presented to support the findings. The report addresses those tasks of the statement of work dedicated to data acquisition, analysis, and energy conservation strategies internal to the Starrett City TEP and the community it supplies as well as to the 26th Ward WPCP. (MCW)

  3. Shock acceleration in partially neutral plasmas

    CERN Document Server

    Morlino, G; Blasi, P; Caprioli, D

    2010-01-01

    We present the non-linear theory of shock acceleration applied to SNRs expanding into partially neutral plasma. Using this theory we show how the Balmer lines detected from young SNRs can be used to test the efficiency of shocks in the production of cosmic rays. In particular we investigate the effect of charge-exchange between protons and neutral hydrogen occurring in the precursor formed ahead of the shock. In this precursor the CR pressure accelerate the ionized component of the plasma and a relative velocity between protons and neutral hydrogen is established. On the other hand the charge-exchange process tends to equilibrate ions and neutrals resulting in the heating of both components. We show that even when the shock converts only a few per cent of the total bulk kinetic energy into CRs, the heating is efficient enough to produce a detectable broadening of the narrow Balmer lines emitted by the neutral hydrogen.

  4. Custom, contract, and kidney exchange.

    Science.gov (United States)

    Healy, Kieran; Krawiec, Kimberly D

    2012-01-01

    In this Essay, we examine a case in which the organizational and logistical demands of a novel form of organ exchange (the nonsimultaneous, extended, altruistic donor (NEAD) chain) do not map cleanly onto standard cultural schemas for either market or gift exchange, resulting in sociological ambiguity and legal uncertainty. In some ways, a NEAD chain resembles a form of generalized exchange, an ancient and widespread instance of the norm of reciprocity that can be thought of simply as the obligation to “pay it forward” rather than the obligation to reciprocate directly with the original giver. At the same time, a NEAD chain resembles a string of promises and commitments to deliver something in exchange for some valuable consideration--that is, a series of contracts. Neither of these salient "social imaginaries" of exchange--gift giving or formal contract--perfectly meets the practical demands of the NEAD system. As a result, neither contract nor generalized exchange drives the practice of NEAD chains. Rather, the majority of actual exchanges still resemble a simpler form of exchange: direct, simultaneous exchange between parties with no time delay or opportunity to back out. If NEAD chains are to reach their full promise for large-scale, nonsimultaneous organ transfer, legal uncertainties and sociological ambiguities must be finessed, both in the practices of the coordinating agencies and in the minds of NEAD-chain participants. This might happen either through the further elaboration of gift-like language and practices, or through a creative use of the cultural form and motivational vocabulary, but not necessarily the legal and institutional machinery, of contract.

  5. Effect of polyamine reagents on exchange capacity in ion exchangers

    Science.gov (United States)

    Petrova, T. I.; Dyachenko, F. V.; Bogatyreva, Yu. V.; Borodastov, A. K.; Ershova, I. S.

    2016-05-01

    Effect of compounds involved in complex reagents is described using Helamin 906H reagent as an example. The working exchange capacity of KU-2-8chs cation exchanger in hydrogen form and Amberlite IRA 900Cl anion exchanger in OH form remained almost unchanged when they were used repeatedly to purify water that contained Helamin 906H reagent; in addition, this capacity was the same upon filtration of water that did not contain this reagent. Leakage of total organic carbon was observed earlier than that of calcium ions upon filtration of the solution through the cation exchanger layer. The test results obtained in industrial conditions indicated that using H-OH filters to purify turbine condensate enables the decrease of the concentration of organic and other impurities therein.

  6. Determination of Lead Isotopic Ratios in Corals by Anion Exchange Resin Technique and High Resolution Inductively Coupled Plasma Mass Spectrometry%阴离子交换树脂分离富集/电感耦合等离子体质谱测定珊瑚中铅的同位素组成

    Institute of Scientific and Technical Information of China (English)

    戴洁; 瞿建国; 张经

    2012-01-01

    在自制微型离子交换柱的基础上,建立了阴离子交换树脂AG1-X8分离富集珊瑚中痕量元素Pb的前处理方法,并使用高分辨电感耦合等离子体质谱( HR - ICP - MS)测定了海南橙黄滨珊瑚(porites lutea)样品中的Pb同位素比值.从全程空白值、洗脱曲线、回收率和基体分离情况等方面考察了不同洗脱剂的洗脱效果,结果表明,采用0.50 mol/L HNO3时的洗脱效果最好,方法的全程空白值为18 pg,Pb的回收率为99.6%,在洗脱过程中无拖尾现象,且能与Ca、Sr、Mg、Fe、Mn、Zn、Ba和U等珊瑚中的基体元素成功分离,对上述基体元素的去除率均能达到99.8%以上.使用该方法测得海南珊瑚样品中的207pb/206 Pb、208Pb/206Pb比值分别为0.850 5、2.087 0,相对标准偏差(RSDs,n=21)分别为0.12%和0.11%.该法质量控制良好,表明建立的AG1-X8阴离子交换树脂分离富集/HR - ICP - MS测定珊瑚中Pb的同位素组成的方法可靠,可推广应用于其它复杂样品中铅同位素组成的测定.%A pretreatment method to enrich trace element Pb in corals was established with AG1-X8 anion exchange resin and self-made PTFE micro column, then Pb isotopic ratios in Hainan corals (porites lutea) in China was measured by high-resolution inductively coupled plasma mass spectrometry (HR - ICP - MS). Several parameters including procedural blank, elution curve, Pb recovery and matrix separation were compared among four different eluents, and the results showed 0. 50 mol/ L HNO3 was the best eluent, of which the procedural blank was 18 pg, and recovery of Pb was 99. 6% , besides, there was no tailing observed and more than 99. 8% of the matrix elements in corals such as Ca, Sr, Mg, Fe, Mn, U, Ba as well as Zn could be well separated from Pb during the eluting process. After eluted with 0. 50 mol/L HNO3 ,207Pb/206Pb and 208Pb/206Pb in Hainan corals was determined to be 0. 850 5 and 2. 087 0, with RSDs(n =21) of 0. 12% and 0. 11

  7. Clinical observation of bilirubin adsorption combined with plasma exchange therapy in the treatment of hepa-topulmonary syndrome respiratory failure%胆红素吸附联合血浆置换治疗肝肺综合征呼吸衰竭的临床观察

    Institute of Scientific and Technical Information of China (English)

    杨春霞; 马小芳; 邓春艳

    2015-01-01

    目的:观察胆红素吸附联合血浆置换治疗肝肺综合征呼吸衰竭效果,探讨作用机制。方法134例各种原因肝病合并肝肺综合征患者随机分为血液净化组和对照组,测定纤支镜肺灌洗液中胆红素、IL-6浓度,监测两组机械通气( MV)参数变化,血气分析监测氧代谢情况,评估血液净化对肝肺综合征合并呼吸功能衰竭的治疗效果。结果与对照组相比,血液净化组纤支镜肺灌洗胆红素浓度、IL-6浓度( P<0.05),均明显下降,机械通气脱机时间早,时间短,呼吸机支持力度小(P<0.05),氧分压升高而肺泡-动脉氧分压差下降(P<0.05),肺功能明显改善。结论血液净化可有效治疗肝肺综合征改善肺功能,纠正呼吸衰竭,原因与清除肺组织局部胆红素沉积、炎症介质等因索有关。%Objective To observe the clinical effect of bilirubin adsorption combined with plasma exchange therapy in the treatment of hepatopulmonary syndrome respiratory failure. Methods 134 cases of various cause liver disease combined with hepatopulmonary syndrome patients were randomly divided into the blood purification group and the control group. The concentration of bilirubin and IL-6 in bronchoscopy lung lavage fluid was determined. Me-chanical ventilation ( MV) parameters, oxygen metabolism and blood gas analysis were monitored. Results Com-pared with the control group, the concentration of bilirubin and IL-6 decreased significantly in the blood purification group (P<0. 05). The blood purification group had earlier weaning time of mechanical ventilation, shorter ventila-tion time, and smaller ventilator support than the control group (P<0. 05). The improvement of pulmonary function was more pronounced in the blood purification group than in the control group. Conclusion Blood purification can effectively improve lung function and correct respiratory failure in the treatment of hepatopulmonary syndrome respira

  8. Exchange Rate Deregulation and Industrial Performance: An ...

    African Journals Online (AJOL)

    FIRST LADY

    Key Words: Exchange Rate, Deregulation, Industrial Performance, Co- integration ... and exchange risk there from. In fact ... factors underscore the importance of exchange rate to the economic well being of ..... Wearing. Apparel, Footwear,.

  9. Hear Exchange Assembly

    Science.gov (United States)

    Lowenstein, Andrew; Sibilia, Marc; Miller, Jeffrey; Tonon, Thomas S.

    2003-05-27

    A heat exchange assembly comprises a plurality of plates disposed in a spaced-apart arrangement, each of the plurality of plates includes a plurality of passages extending internally from a first end to a second end for directing flow of a heat transfer fluid in a first plane, a plurality of first end-piece members equaling the number of plates and a plurality of second end-piece members also equaling the number of plates, each of the first and second end-piece members including a recessed region adapted to fluidly connect and couple with the first and second ends of the plate, respectively, and further adapted to be affixed to respective adjacent first and second end-piece members in a stacked formation, and each of the first and second end-piece members further including at least one cavity for enabling entry of the heat transfer fluid into the plate, exit of the heat transfer fluid from the plate, or 180.degree. turning of the fluid within the plate to create a serpentine-like fluid flow path between points of entry and exit of the fluid, and at least two fluid conduits extending through the stacked plurality of first and second end-piece members for providing first fluid connections between the parallel fluid entry points of adjacent plates and a fluid supply inlet, and second fluid connections between the parallel fluid exit points of adjacent plates and a fluid discharge outlet so that the heat transfer fluid travels in parallel paths through each respective plate.

  10. Separation of proteins from human plasma by sample displacement chromatography in hydrophobic interaction mode

    OpenAIRE

    Josic, Djuro; Breen, Lucas; Clifton, James; Gajdosik, Martina Srajer; Gaso-Sokac, Dajana; Rucevic, Marijana; Müller, Egbert

    2012-01-01

    Sample displacement chromatography (SDC) in reversed-phase and ion-exchange modes was introduced approximately twenty years ago. This method was first used for the preparative purification of peptides and proteins. Recently, SDC in ion-exchange mode was also successfully used for enrichment of low abundance proteins from human plasma. In this paper, the use of SDC for the separation of plasma proteins in hydrophobic interaction mode is demonstrated. By use of two or more columns coupled in se...

  11. Heat exchanger using graphite foam

    Science.gov (United States)

    Campagna, Michael Joseph; Callas, James John

    2012-09-25

    A heat exchanger is disclosed. The heat exchanger may have an inlet configured to receive a first fluid and an outlet configured to discharge the first fluid. The heat exchanger may further have at least one passageway configured to conduct the first fluid from the inlet to the outlet. The at least one passageway may be composed of a graphite foam and a layer of graphite material on the exterior of the graphite foam. The layer of graphite material may form at least a partial barrier between the first fluid and a second fluid external to the at least one passageway.

  12. Ion temperature evolution in an ultracold neutral plasma

    Energy Technology Data Exchange (ETDEWEB)

    McQuillen, P., E-mail: patrickmcquillen@rice.edu; Strickler, T.; Langin, T.; Killian, T. C. [Department of Physics and Astronomy, Rice University, Houston, Texas 77005 (United States)

    2015-03-15

    We study the long-time evolution of the ion temperature in an expanding ultracold neutral plasma using spatially resolved, laser-induced-fluorescence spectroscopy. Adiabatic cooling reduces the ion temperature by an order of magnitude during the plasma expansion, to temperatures as low as 0.2 K. Cooling is limited by heat exchange between ions and the much hotter electrons. We also present evidence for an additional heating mechanism and discuss possible sources. Data are described by a model of the plasma evolution, including the effects of ion-electron heat exchange. We show that for appropriate initial conditions, the degree of Coulomb coupling of ions in the plasma increases during expansion.

  13. Ion Temperature Evolution in an Ultracold Neutral Plasma

    CERN Document Server

    McQuillen, P; Langin, T; Killian, T C

    2015-01-01

    We study the long-time evolution of the ion temperature in an expanding ultracold neutral plasma using spatially resolved, laser-induced-fluorescence spectroscopy. Adiabatic cooling reduces the ion temperature by an order of magnitude during the plasma expansion, to temperatures as low as 0.2 K. Cooling is limited by heat exchange between ions and the much hotter electrons. We also present evidence for an additional heating mechanism and discuss possible sources. Data are described by a model of the plasma evolution, including the effects of ion-electron heat exchange. We show that for appropriate initial conditions, the degree of Coulomb coupling of ions in the plasma increases during expansion.

  14. Plasma Free Metanephrines

    Science.gov (United States)

    ... be limited. Home Visit Global Sites Search Help? Plasma Free Metanephrines Share this page: Was this page helpful? Also known as: Plasma Metanephrines Formal name: Fractionated Plasma Free Metanephrines (Metanephrine ...

  15. Improved plasma accelerator

    Science.gov (United States)

    Cheng, D. Y.

    1971-01-01

    Converging, coaxial accelerator electrode configuration operates in vacuum as plasma gun. Plasma forms by periodic injections of high pressure gas that is ionized by electrical discharges. Deflagration mode of discharge provides acceleration, and converging contours of plasma gun provide focusing.

  16. Plasma physics and fusion plasma electrodynamics

    CERN Document Server

    Bers, Abraham

    2016-01-01

    Plasma is a ubiquitous state of matter at high temperatures. The electrodynamics of plasmas encompasses a large number of applications, from understanding plasmas in space and the stars, to their use in processing semiconductors, and their role in controlled energy generation by nuclear fusion. This book covers collective and single particle dynamics of plasmas for fully ionized as well as partially ionized plasmas. Many aspects of plasma physics in current fusion energy generation research are addressed both in magnetic and inertial confinement plasmas. Linear and nonlinear dynamics in hydrodynamic and kinetic descriptions are offered, making both simple and complex aspects of the subject available in nearly every chapter. The approach of dividing the basic aspects of plasma physics as "linear, hydrodynamic descriptions" to be covered first because they are "easier", and postponing the "nonlinear and kinetic descriptions" for later because they are "difficult" is abandoned in this book. For teaching purpose...

  17. Microsoft Exchange Server 2010 -palvelinprojekti

    OpenAIRE

    Loise, Niklas

    2011-01-01

    Tämän opinnäytetyön tavoitteena on tutkia kuinka, hyvin Exchange Server 2010 -sähköpostijärjestelmä pystyy vastaamaan Päijät-Hämeen koulutuskonsernin työntekijöiden asettamiin vaatimuksiin ja korvaamaan vanhan Novell GroupWise 8 -järjestelmän. Työssä selvitetään Exchange 2010:n uudet ominaisuudet ja tärkeimmät toiminnot. Exchange Server 2010 on Microsoftin viimeisin viestintäpalvelinratkaisu, joka sisältää sähköposti-, kalenteri-, yhteystieto- ja vastaajaratkaisut. Exchange 2010 toimii W...

  18. Counterflow Regolith Heat Exchanger Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The counterflow regolith heat exchanger (CoRHE) is a device that transfers heat from hot regolith to cold regolith. The CoRHE is essentially a tube-in-tube heat...

  19. Quantum Exchangeable Sequences of Algebras

    CERN Document Server

    Curran, Stephen

    2008-01-01

    We extend the notion of quantum exchangeability, introduced by K\\"ostler and Speicher in arXiv:0807.0677, to sequences (\\rho_1,\\rho_2,...c) of homomorphisms from an algebra C into a noncommutative probability space (A,\\phi), and prove a free de Finetti theorem: an infinite quantum exchangeable sequence (\\rho_1,\\rho_2,...c) is freely independent and identically distributed with respect to a conditional expectation. As a corollary we obtain a free analogue of the Hewitt Savage zero-one law. As in the classical case, the theorem fails for finite sequences. We give a characterization of finite quantum exchangeable sequences, which can be viewed as a noncommutative analogue of sampling without replacement. We then give an approximation to how far a finite quantum exchangeable sequence is from being freely independent with amalgamation.

  20. Exchange couplings in magnetic films

    Institute of Scientific and Technical Information of China (English)

    Liu Wei; Liu Xiong-Hua; Cui Wei-Bin; Gong Wen-Jie; Zhang Zhi-Dong

    2013-01-01

    Recent advances in the study of exchange couplings in magnetic films are introduced.To provide a comprehensive understanding of exchange coupling,we have designed different bilayers,trilayers and multilayers,such as anisotropic hard/soft-magnetic multilayer films,ferromagnetic/antiferromagnetic/ferromagnetic trilayers,[Pt/Co]/NiFe/NiO heterostructures,Co/NiO and Co/NiO/Fe trilayers on an anodic aluminum oxide (AAO) template.The exchange-coupling interaction between soft-and hard-magnetic phases,interlayer and interfacial exchange couplings and magnetic and magnetotransport properties in these magnetic films have been investigated in detail by adjusting the magnetic anisotropy of ferromagnetic layers and by changing the thickness of the spacer layer,ferromagnetic layer,and antiferromagnetic layer.Some particular physical phenomena have been observed and explained.

  1. VLER Health Exchange by Area

    Data.gov (United States)

    Department of Veterans Affairs — “Connect Your Docs” through the Virtual Lifetime Electronic Record (VLER) Health Exchange program. This program gives VA and community health care providers secure...

  2. Identifiability, exchangeability and confounding revisited

    OpenAIRE

    Greenland, Sander; Robins, James Matthew

    2009-01-01

    In 1986 the International Journal of Epidemiology published "Identifiability, Exchangeability and Epidemiological Confounding". We review the article from the perspective of a quarter century after it was first drafted and relate it to subsequent developments on confounding, ignorability, and collapsibility.

  3. Yuan Exchange Rate 'Properly Adjusted'

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

      The currency exchange rate was "properly adjusted" this year and takes into account effects on the country's neighbors and the world, Premier Wen Jiabao said at a regional meeting in Malaysia.……

  4. Estimating Foreign Exchange Reserve Adequacy

    Directory of Open Access Journals (Sweden)

    Abdul Hakim

    2013-04-01

    Full Text Available Accumulating foreign exchange reserves, despite their cost and their impacts on other macroeconomics variables, provides some benefits. This paper models such foreign exchange reserves. To measure the adequacy of foreign exchange reserves for import, it uses total reserves-to-import ratio (TRM. The chosen independent variables are gross domestic product growth, exchange rates, opportunity cost, and a dummy variable separating the pre and post 1997 Asian financial crisis. To estimate the risky TRM value, this paper uses conditional Value-at-Risk (VaR, with the help of Glosten-Jagannathan-Runkle (GJR model to estimate the conditional volatility. The results suggest that all independent variables significantly influence TRM. They also suggest that the short and long run volatilities are evident, with the additional evidence of asymmetric effects of negative and positive past shocks. The VaR, which are calculated assuming both normal and t distributions, provide similar results, namely violations in 2005 and 2008.

  5. Pu Anion Exchange Process Intensification

    Energy Technology Data Exchange (ETDEWEB)

    Taylor-Pashow, K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-08

    This project seeks to improve the efficiency of the plutonium anion-exchange process for purifying Pu through the development of alternate ion-exchange media. The objective of the project in FY15 was to develop and test a porous foam monolith material that could serve as a replacement for the current anion-exchange resin, Reillex® HPQ, used at the Savannah River Site (SRS) for purifying Pu. The new material provides advantages in efficiency over the current resin by the elimination of diffusive mass transport through large granular resin beads. By replacing the large resin beads with a porous foam there is much more efficient contact between the Pu solution and the anion-exchange sites present on the material. Several samples of a polystyrene based foam grafted with poly(4-vinylpyridine) were prepared and the Pu sorption was tested in batch contact tests.

  6. Anion exchange polymer electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yu Seung; Kim, Dae Sik; Lee, Kwan-Soo

    2013-07-23

    Solid anion exchange polymer electrolytes and compositions comprising chemical compounds comprising a polymeric core, a spacer A, and a guanidine base, wherein said chemical compound is uniformly dispersed in a suitable solvent and has the structure: ##STR00001## wherein: i) A is a spacer having the structure O, S, SO.sub.2, --NH--, --N(CH.sub.2).sub.n, wherein n=1-10, --(CH.sub.2).sub.n--CH.sub.3--, wherein n=1-10, SO.sub.2-Ph, CO-Ph, ##STR00002## wherein R.sub.5, R.sub.6, R.sub.7 and R.sub.8 each are independently --H, --NH.sub.2, F, Cl, Br, CN, or a C.sub.1-C.sub.6 alkyl group, or any combination of thereof; ii) R.sub.9, R.sub.10, R.sub.11, R.sub.12, or R.sub.13 each independently are --H, --CH.sub.3, --NH.sub.2, --NO, --CH.sub.nCH.sub.3 where n=1-6, HC.dbd.O--, NH.sub.2C.dbd.O--, --CH.sub.nCOOH where n=1-6, --(CH.sub.2).sub.n--C(NH.sub.2)--COOH where n=1-6, --CH--(COOH)--CH.sub.2--COOH, --CH.sub.2--CH(O--CH.sub.2CH.sub.3).sub.2, --(C.dbd.S)--NH.sub.2, --(C.dbd.NH)--N--(CH.sub.2).sub.nCH.sub.3, where n=0-6, --NH--(C.dbd.S)--SH, --CH.sub.2--(C.dbd.O)--O--C(CH.sub.3).sub.3, --O--(CH.sub.2).sub.n--CH--(NH.sub.2)--COOH, where n=1-6, --(CH.sub.2).sub.n--CH.dbd.CH wherein n=1-6, --(CH.sub.2).sub.n--CH--CN wherein n=1-6, an aromatic group such as a phenyl, benzyl, phenoxy, methylbenzyl, nitrogen-substituted benzyl or phenyl groups, a halide, or halide-substituted methyl groups; and iii) wherein the composition is suitable for use in a membrane electrode assembly.

  7. Universality in the stock exchange

    CERN Document Server

    Gonçalves, Rui

    2008-01-01

    We analyze the constituents stocks of the Dow Jones Industrial Average and the Standard & Poor's 100 index of the NYSE stock exchange market. Surprisingly, we discovered that the distribution of the fluctuations of the cubic root of the squared daily return are close to the universal non-parametric Bramwell-Holdsworth-Pinton (BHP) distribution. Since the BHP probability density function appears in several other dissimilar phenomena, our result reveals an universal feature of the stock exchange market.

  8. Shared Year Exchange in Nursing

    DEFF Research Database (Denmark)

    Vedsegaard, Helle Wendner; Wederkinck, Elisabeth

    2010-01-01

    Beskrivelse af Shared Year Exchange in Nursing, et udviklingsporjekt omhandlende udvikling, beskrivelse og implementering af et fælles studieår for sygeplejerskestuderende ved Metropol og La Trobe University Australien.......Beskrivelse af Shared Year Exchange in Nursing, et udviklingsporjekt omhandlende udvikling, beskrivelse og implementering af et fælles studieår for sygeplejerskestuderende ved Metropol og La Trobe University Australien....

  9. Implementation of a plasma-neutral model in NIMROD

    Science.gov (United States)

    Taheri, S.; Shumlak, U.; King, J. R.

    2016-10-01

    Interaction between plasma fluid and neutral species is of great importance in the edge region of magnetically confined fusion plasmas. The presence of neutrals can have beneficial effects such as fueling burning plasmas and quenching the disruptions in tokamaks, as well as deleterious effects like depositing high energy particles on the vessel wall. The behavior of edge plasmas in magnetically confined systems has been investigated using computational approaches that utilize the fluid description for the plasma and Monte Carlo transport for neutrals. In this research a reacting plasma-neutral model is implemented in NIMROD to study the interaction between plasma and neutral fluids. This model, developed by E. T. Meier and U. Shumlak, combines a single-fluid magnetohydrodynamic (MHD) plasma model with a gas dynamic neutral fluid model which accounts for electron-impact ionization, radiative recombination, and resonant charge exchange. Incorporating this model into NIMROD allows the study of the interaction between neutrals and plasma in a variety of plasma science problems. An accelerated plasma moving through a neutral gas background in a coaxial electrode configuration is modeled, and the results are compared with previous calculations from the HiFi code.

  10. Electrostatic two-stream instability in Fermi-Dirac plasmas

    Science.gov (United States)

    Akbari-Moghanjoughi, M.; Mohammadnejad, M.; Esfandyari-Kalejahi, A.

    2016-09-01

    In this paper the electrostatic two-stream instability is investigated for a large range of plasma number-density using the quantum hydrodynamic model by incorporating the relativistic degeneracy, electron-exchange, quantum diffraction and strong parallel quantizing magnetic field effects. It is found that the electron diffraction effect significantly alters the instability growth rate in a wide range of plasma number density. Two cases of classical and quantum Landau quantization limits are compared and the parametric instability condition is closely inspected. It is remarked that for a given streaming speed the instability is bounded by an upper plasma number-density limit. It is also shown that for a given stream speed there is a maximal growth rate corresponding to specific plasma number-density and perturbation wavelength. Current study can help in better understanding of electron-beam plasma interactions and energy exchange for a wide area of number densities ranging from solid density, inertial confined plasmas, big planetary cores and compact stars. It may also be useful in understanding of electrostatic beam-plasma interactions and origin of large magnitude sustainable electrical currents in super-intense plasmas with critically high magnetic fields such as, pulsars, white dwarf interiors and neutron star crusts.

  11. Fusion plasma physics

    CERN Document Server

    Stacey, Weston M

    2012-01-01

    This revised and enlarged second edition of the popular textbook and reference contains comprehensive treatments of both the established foundations of magnetic fusion plasma physics and of the newly developing areas of active research. It concludes with a look ahead to fusion power reactors of the future. The well-established topics of fusion plasma physics -- basic plasma phenomena, Coulomb scattering, drifts of charged particles in magnetic and electric fields, plasma confinement by magnetic fields, kinetic and fluid collective plasma theories, plasma equilibria and flux surface geometry, plasma waves and instabilities, classical and neoclassical transport, plasma-materials interactions, radiation, etc. -- are fully developed from first principles through to the computational models employed in modern plasma physics. The new and emerging topics of fusion plasma physics research -- fluctuation-driven plasma transport and gyrokinetic/gyrofluid computational methodology, the physics of the divertor, neutral ...

  12. International movement of plasma and plasma contracting.

    Science.gov (United States)

    Farrugia, A

    2005-01-01

    Plasma fractionation is a global business characterised by technological stability, increasing consolidation and a high level of regulatory oversight. All these factors affect the ease with which plasma derivatives can be accessed in the world market. As domestic regulatory measures in the first world blood economies become increasingly resonant to the precautionary approach, the availability of plasma as a raw material, as well as its cost, become an increasingly significant component in the cost of the final product. This decreases the amount of plasma which fractionators are able to allocate for export activities. Also, regulatory standards in the country of manufacture will reflect priorities in that country which may not be similar to those in export markets, but which will affect entry to those markets. While many countries possess a fractionation capacity, the limiting factor in supply worldwide is the amount of plasma available, and nationalistic drivers for each country to have its own plant are inimical to product safety and supply. Rather, the provision of sufficient supplies of domestic plasma should be the focus of resource allocation, with a choice of an appropriate contract fractionator. However, contract fractionation too may be affected by domestic considerations unrelated to the needs of the country of plasma origin. This chapter will review the global plasma market and the influences on plasma and plasma product movement across national borders. Problems in ensuring adequate safety and supply will be identified, and some tentative approaches to the amelioration of current barriers to the provision of plasma derivatives will be outlined.

  13. Lifetime of quasiparticles in hot QED plasmas

    CERN Document Server

    Blaizot, J P; Blaizot, Jean Paul; Iancu, Edmond

    1996-01-01

    The calculation of the lifetime of quasiparticles in a QED plasma at high temperature remains plagued with infrared divergences, even after one has taken into account the screening corrections. The physical processes responsible for these divergences are the collisions involving the exchange of very soft, unscreened, magnetic photons, whose contribution is enhanced by the thermal Bose-Einstein occupation factor. The self energy diagrams which diverge in perturbation theory contain no internal fermion loops, but an arbitrary number of internal magnetostatic photon lines. By generalizing the Bloch-Nordsieck model at finite temperature, we can resum all the singular contributions of such diagrams, and obtain the correct long time behaviour of the retarded fermion propagator in the hot QED plasma: S_R(t)\\sim \\exp\\{-\\alpha T \\, t\\, \\ln\\omega_pt\\}, where \\omega_p=eT/3 is the plasma frequency and \\alpha=e^2/4\\pi.

  14. Does Remuneration for Plasma Compromise Autonomy?

    Science.gov (United States)

    White, Lucie

    2015-12-01

    In accordance with a recent statement released by the World Health Organization, the Canadian province of Ontario is moving to ban payment for plasma donation. This is partially based on contentions that remuneration for blood and blood products undermines autonomy and personal dignity. This paper is dedicated to evaluating this claim. I suggest that traditional autonomy-based arguments against commodification of human body parts and substances are less compelling in the context of plasma donation in Canada, but that there is another autonomy-based objection to paid plasma donation that has not received sufficient attention. Namely, the stigma that surrounds exchanging plasma for payment makes it difficult to make an autonomous decision to engage in this activity. I suggest that this problem can be overcome in one of two ways; by banning payment for plasma, or by reducing the stigma surrounding this practice. I provide an indication of how we might work to achieve the latter, contending that this possibility should be taken seriously, due to the difficulties in achieving a sufficient supply of plasma without remuneration.

  15. Nominal exchange rate flexibility and real exchange rate adjustment : evidence from dual exchange rates in developing countries

    OpenAIRE

    Cheung, Yin-Wong; Lai, Kon-Sun

    2005-01-01

    This study investigates whether exchange rate flexibility aids real exchange rate adjustment based on intra-period data on dual exchange rates from developing countries. Specifically, it analyzes whether the flexible parallel market rate produces faster or slower real exchange rate adjustment than the much less flexible official rate does. Half-life estimates of adjustment speeds are obtained using fractional time series analysis. We find no systematic evidence that greater exchange rate flex...

  16. Communication through Plasma Sheaths

    CERN Document Server

    Korotkevich, A O; Zakharov, V E

    2007-01-01

    We wish to transmit messages to and from a hypersonic vehicle around which a plasma sheath has formed. For long distance transmission, the signal carrying these messages must be necessarily low frequency, typically 2 GHz, to which the plasma sheath is opaque. The idea is to use the plasma properties to make the plasma sheath appear transparent.

  17. 22 CFR 41.62 - Exchange visitors.

    Science.gov (United States)

    2010-04-01

    ... NATIONALITY ACT, AS AMENDED Students and Exchange Visitors § 41.62 Exchange visitors. (a) J-1 classification. An alien is classifiable as an exchange visitor if qualified under the provisions of INA 101(a) (15... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Exchange visitors. 41.62 Section 41.62 Foreign...

  18. High spatial and temporal resolution charge exchange recombination spectroscopy on the HL-2A tokamak

    NARCIS (Netherlands)

    Wei, Y. L.; Yu, D. L.; Liu, L.; Ida, K.; von Hellermann, M.; Cao, J. Y.; Sun, A. P.; Ma, Q.; Chen, W. J.; Liu, Yi; Yan, L. W.; Yang, Q. W.; Duan, X. R.; Liu, Yong

    2014-01-01

    A 32/64-channel charge exchange recombination spectroscopy (CXRS) diagnostic system is developed on the HL-2A tokamak (R = 1.65 m, a = 0.4 m), monitoring plasma ion temperature and toroidal rotation velocity simultaneously. A high throughput spectrometer (F/2.8) and a pitch-controlled fiber bundle e

  19. Membrane association of the Arabidopsis ARF exchange factor GNOM involves interaction of conserved domains

    DEFF Research Database (Denmark)

    Anders, Nadine; Nielsen, Michael M.; Keicher, Jutta;

    2008-01-01

    The GNOM protein plays a fundamental role in Arabidopsis thaliana development by regulating endosome-to-plasma membrane trafficking required for polar localization of the auxin efflux carrier PIN1. GNOM is a family member of large ARF guanine nucleotide exchange factors (ARF-GEFs), which regulate...

  20. Conceptual design of the ITER upper port plug for charge exchange diagnostic

    NARCIS (Netherlands)

    Sadakov, S.; Baross, T.; Biel, W.; Borsuk, V.; Hawkes, N.; Hellermann, M. von; Gille, P.; Kiss, G.; Koning, J.; Knaup, M.; Klinkhamer, J.F.F.; Krasikov, Yu.; Litnovsky, A.; Neubauer, O.; Panin, A.

    2009-01-01

    A plug for the ITER core charge exchange recombination spectroscopy (core CXRS) is located in the upper port 3. It transfers the light emitted by interaction of plasma ions with the diagnostic neutral beam (DNB). The plug consists of a main shell, a shielding cassette and a retractable tube. The tub

  1. Introduction to plasma dynamics

    CERN Document Server

    Morozov, A I

    2013-01-01

    As the twenty-first century progresses, plasma technology will play an increasing role in our lives, providing new sources of energy, ion-plasma processing of materials, wave electromagnetic radiation sources, space plasma thrusters, and more. Studies of the plasma state of matter not only accelerate technological developments but also improve the understanding of natural phenomena. Beginning with an introduction to the characteristics and types of plasmas, Introduction to Plasma Dynamics covers the basic models of classical diffuse plasmas used to describe such phenomena as linear and shock w

  2. Lipid exchange between Borrelia burgdorferi and host cells.

    Directory of Open Access Journals (Sweden)

    Jameson T Crowley

    2013-01-01

    Full Text Available Borrelia burgdorferi, the agent of Lyme disease, has cholesterol and cholesterol-glycolipids that are essential for bacterial fitness, are antigenic, and could be important in mediating interactions with cells of the eukaryotic host. We show that the spirochetes can acquire cholesterol from plasma membranes of epithelial cells. In addition, through fluorescent and confocal microscopy combined with biochemical approaches, we demonstrated that B. burgdorferi labeled with the fluorescent cholesterol analog BODIPY-cholesterol or (3H-labeled cholesterol transfer both cholesterol and cholesterol-glycolipids to HeLa cells. The transfer occurs through two different mechanisms, by direct contact between the bacteria and eukaryotic cell and/or through release of outer membrane vesicles. Thus, two-way lipid exchange between spirochetes and host cells can occur. This lipid exchange could be an important process that contributes to the pathogenesis of Lyme disease.

  3. Hartree potential dependent exchange functional

    CERN Document Server

    Constantin, L A; Della Sala, F

    2016-01-01

    We introduce a novel non-local ingredient for the construction of exchange density functionals: the reduced Hartree parameter, which is invariant under the uniform scaling of the density and represents the exact exchange enhancement factor for one- and two-electron systems. The reduced Hartree parameter is used together with the conventional meta-generalized gradient approximation (meta-GGA) semilocal ingredients (i.e. the electron density, its gradient and the kinetic energy density) to construct a new generation exchange functional, termed u-meta-GGA. This u-meta-GGA functional is exact for {the exchange of} any one- and two-electron systems, is size-consistent and non-empirical, satisfies the uniform density scaling relation, and recovers the modified gradient expansion derived from the semiclassical atom theory. For atoms, ions, jellium spheres, and molecules, it shows a good accuracy, being often better than meta-GGA exchange functionals. Our construction validates the use of the reduced Hartree ingredie...

  4. Fair Exchange in Strand Spaces

    Directory of Open Access Journals (Sweden)

    Joshua D. Guttman

    2009-10-01

    Full Text Available Many cryptographic protocols are intended to coordinate state changes among principals. Exchange protocols coordinate delivery of new values to the participants, e.g. additions to the set of values they possess. An exchange protocol is fair if it ensures that delivery of new values is balanced: If one participant obtains a new possession via the protocol, then all other participants will, too. Fair exchange requires progress assumptions, unlike some other protocol properties. The strand space model is a framework for design and verification of cryptographic protocols. A strand is a local behavior of a single principal in a single session of a protocol. A bundle is a partially ordered global execution built from protocol strands and adversary activities. The strand space model needs two additions for fair exchange protocols. First, we regard the state as a multiset of facts, and we allow strands to cause changes in this state via multiset rewriting. Second, progress assumptions stipulate that some channels are resilient-and guaranteed to deliver messages-and some principals are assumed not to stop at certain critical steps. This method leads to proofs of correctness that cleanly separate protocol properties, such as authentication and confidentiality, from invariants governing state evolution. G. Wang's recent fair exchange protocol illustrates the approach.

  5. Electrically Switched Cesium Ion Exchange

    Energy Technology Data Exchange (ETDEWEB)

    JPH Sukamto; ML Lilga; RK Orth

    1998-10-23

    This report discusses the results of work to develop Electrically Switched Ion Exchange (ESIX) for separations of ions from waste streams relevant to DOE site clean-up. ESIX combines ion exchange and electrochemistry to provide a selective, reversible method for radionuclide separation that lowers costs and minimizes secondary waste generation typically associated with conventional ion exchange. In the ESIX process, an electroactive ion exchange film is deposited onto. a high surface area electrode, and ion uptake and elution are controlled directly by modulating the potential of the film. As a result, the production of secondary waste is minimized, since the large volumes of solution associated with elution, wash, and regeneration cycles typical of standard ion exchange are not needed for the ESIX process. The document is presented in two parts: Part I, the Summary Report, discusses the objectives of the project, describes the ESIX concept and the approach taken, and summarizes the major results; Part II, the Technology Description, provides a technical description of the experimental procedures and in-depth discussions on modeling, case studies, and cost comparisons between ESIX and currently used technologies.

  6. Collisionless plasmas in astrophysics

    CERN Document Server

    Belmont, Gerard; Mottez, Fabrice; Pantellini, Filippo; Pelletier, Guy

    2013-01-01

    Collisionless Plasmas in Astrophysics examines the unique properties of media without collisions in plasma physics. Experts in this field, the authors present the first book to concentrate on collisionless conditions in plasmas, whether close or not to thermal equilibrium. Filling a void in scientific literature, Collisionless Plasmas in Astrophysics explains the possibilities of modeling such plasmas, using a fluid or a kinetic framework. It also addresses common misconceptions that even professionals may possess, on phenomena such as "collisionless (Landau) damping". Abundant illustrations

  7. Epithelial cell-cell junctions and plasma membrane domains

    NARCIS (Netherlands)

    Giepmans, Ben N. G.; van Ijzendoorn, Sven C. D.

    Epithelial cells form a barrier against the environment, but are also required for the regulated exchange of molecules between an organism and its surroundings. Epithelial cells are characterised by a remarkable polarization of their plasma membrane, evidenced by the appearance of structurally,

  8. Epithelial cell-cell junctions and plasma membrane domains

    NARCIS (Netherlands)

    Giepmans, Ben N. G.; van Ijzendoorn, Sven C. D.

    2009-01-01

    Epithelial cells form a barrier against the environment, but are also required for the regulated exchange of molecules between an organism and its surroundings. Epithelial cells are characterised by a remarkable polarization of their plasma membrane, evidenced by the appearance of structurally, comp

  9. Laboratory study of collisionless coupling between explosive debris plasma and magnetized ambient plasma

    Science.gov (United States)

    Bondarenko, A. S.; Schaeffer, D. B.; Everson, E. T.; Clark, S. E.; Lee, B. R.; Constantin, C. G.; Vincena, S.; Van Compernolle, B.; Tripathi, S. K. P.; Winske, D.; Niemann, C.

    2017-08-01

    The explosive expansion of a localized plasma cloud into a relatively tenuous, magnetized, ambient plasma characterizes a variety of astrophysical and space phenomena. In these rarified environments, collisionless electromagnetic processes rather than Coulomb collisions typically mediate the transfer of momentum and energy from the expanding "debris" plasma to the surrounding ambient plasma. In an effort to better understand the detailed physics of collisionless coupling mechanisms, compliment in situ measurements of space phenomena, and provide validation of previous computational and theoretical work, the present research jointly utilizes the Large Plasma Device and the Raptor laser facility at the University of California, Los Angeles to study the super-Alfvénic, quasi-perpendicular expansion of laser-produced carbon (C) and hydrogen (H) debris plasma through preformed, magnetized helium (He) ambient plasma via a variety of diagnostics, including emission spectroscopy, wavelength-filtered imaging, and a magnetic flux probe. Doppler shifts detected in a He1+ ion spectral line indicate that the ambient ions initially accelerate transverse to both the debris plasma flow and the background magnetic field. A qualitative analysis in the framework of a "hybrid" plasma model (kinetic ions and inertia-less fluid electrons) demonstrates that the ambient ion trajectories are consistent with the large-scale laminar electric field expected to develop due to the expanding debris. In particular, the transverse ambient ion motion provides direct evidence of Larmor coupling, a collisionless momentum exchange mechanism that has received extensive theoretical and numerical investigation. In order to quantitatively evaluate the observed Doppler shifts, a custom simulation utilizing a detailed model of the laser-produced debris plasma evolution calculates the laminar electric field and computes the initial response of a distribution of ambient test ions. A synthetic Doppler

  10. Analysis of clinical features and risk factors of fungal infections of patients with liver failure after plasma exchange%血浆置换后肝功能衰竭患者真菌感染临床特点及其预后危险因素分析

    Institute of Scientific and Technical Information of China (English)

    于建武; 孙丽杰; 康鹏; 李树臣

    2008-01-01

    Objective To study clinical features and predisposing risk faetors of fungal infections after plasma exchange(PE)in patients with liver failure.Methods The clinical data and prognosis of 31 liver failure patients with fungal infections after PE were retrospectively analyzed.The risk factor of the fungal infections was studied by univariatc analysis.The risk factor of the prognosis of patients was studied by multivariate analysis.Results The rate of fungal infections in patients with liver failure after PE was 31.0%.Fungal infections presented in oral cavity(61.3%),lung(32.3%),intestinal tract(19.4%),uropoietic system(9.7%),abdominal cavity(6.5%),blood(6.5%)and dwell catheter(3.2%).The confirmed pathogens included Candida albicans(58.1%),Candida tropicalis (12.9%),classified budding fungus(6.5%),Aspergillus(12.9%)and mold fungus(9.7%).Univariate analysis showed that fungal infections was significantly related to glucocorticoid(X2=5.201,P=0.023),antibiotic(X2=7.979,P=0.005),hypo-neutrophil(X2=14.373,P<0.01),bacterial infection(X2=6.955,P=0.008).model for end-stage liver disease(MELD)score(X2=12.548,P<0.01),PE frequency(X2=9.878,P=0.002),but not associated with sex(P=0.795),age(P=0.959)or hypoproteinemia(P=0.482).The mortality of fungal infections in patients with liver failure after PE was 80.6%.According to multivariate analysis,plural pathogenic infection(P=0.012),MELD score(P=0.021)and multi-location of fungal infection(P=0.004)were independent predictors of patients mortality.Conclusions The rate of fungal infections increases in patients with liver failure after PE,which can result in higher mortality.Plural pathogenic infection,MELD score and multi-location of fungal infection are related with the prognosis of patients.%目的 了解血浆置换(PE)后肝功能衰竭患者真菌感染的临床特征、易感因素以及影响患者预后的危险因素.方法 对PE后肝功能衰竭合并真菌感染的31例患者的临床资料及转归进行回顾性分

  11. Colloidal Plasmas : Basic physics of colloidal plasmas

    Indian Academy of Sciences (India)

    C B Dwivedi

    2000-11-01

    Colloidal plasma is a distinct class of the impure plasmas with multispecies ionic composition. The distinction lies in the phase distribution of the impurity-ion species. The ability to tailor the electrostatic interactions between these colloidal particles provides a fertile ground for scientists to investigate the fundamental aspects of the Coulomb phase transition behavior. The present contribution will review the basic physics of the charging mechanism of the colloidal particles as well as the physics of the collective normal mode behavior of the general multi-ion species plasmas. Emphasis will be laid on the clarification of the prevailing confusing ideas about distinct qualities of the various acoustic modes, which are likely to exist in colloidal plasmas as well as in normal multi-ion species plasmas. Introductory ideas about the proposed physical models for the Coulomb phase transition in colloidal plasma will also be discussed.

  12. Complex Spectra in Fusion Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Hellermann, M.G. von; Jaspers, R. [FOM-Institute for Plasma Physics Rijnhuizen, Nieuwegein (Netherlands); Bertschinger, G.; Biel, W.; Marchuk, O. [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Plasmaphysik; Giroud, C.; Zastrow, K.D. [UKAEA Culham Laboratory Euratom Association, Abingdon (United Kingdom); Jupen, C. [Univ. of Lund (Sweden). Physics Dept.; O' Mullane, M.; Summers, H.P.; Whiteford, A. [Univ. of Strathclyde, Glasgow (United Kingdom). Applied Physics Dept.

    2005-12-15

    The need for quantitative evaluation of complex line emission spectra as observed in hot fusion plasmas initiated a challenging development of sophisticated interpretation tools based on integrating advanced atomic modelling with detailed treatment of the plasma environment. The successful merging of the two worlds has led to routine diagnostic procedures which have contributed enormously to the understanding of underlying plasma processes and also to a wide acceptance of spectroscopy as a reliable diagnostic method. In this paper three characteristic types of spectra of current and continuing interest are presented. The first is that of medium/heavy species with many ionisation stages revealed in survey VUV and XUV spectra. Such species occur as control gases, as wall materials, as ablated heavy species and possible as layered wall dopants for monitoring erosion. The spectra are complex with line-like and quasi-continuum regions and are amenable to advanced ?pattern recognition' methods. The second type is of few electron, highly ionised systems observed as line-of-sight integrated passive emission spectra in the soft X-ray region. They are analysed successfully in terms of plasma parameters through matching of observation with predicted synthetic spectra. Examples used here include highly resolved helium-like emission spectra of argon, iron and titanium observed on the tokamaks TEXTOR and Tore Supra. The third type, and the emphasis of this work, comprises spectra linked to active beam spectroscopy, that is, charge exchange recombination spectroscopy (CXRS) and beam emission spectroscopy (BES). In this case, a complex spectrum is again composed of a (usually) dominating active spectrum and an underlying passive emission spectrum. Its analysis requires modelling of both active and passive features. Examples used here are from the CXRS diagnostic at JET and TEXTOR. They display characteristic features of the main light impurity ions (C{sup +6}, He{sup +2}, N

  13. CORRELATIONS IN CONFINED QUANTUM PLASMAS

    Energy Technology Data Exchange (ETDEWEB)

    DUFTY J W

    2012-01-11

    This is the final report for the project 'Correlations in Confined Quantum Plasmas', NSF-DOE Partnership Grant DE FG02 07ER54946, 8/1/2007 - 7/30/2010. The research was performed in collaboration with a group at Christian Albrechts University (CAU), Kiel, Germany. That collaboration, almost 15 years old, was formalized during the past four years under this NSF-DOE Partnership Grant to support graduate students at the two institutions and to facilitate frequent exchange visits. The research was focused on exploring the frontiers of charged particle physics evolving from new experimental access to unusual states associated with confinement. Particular attention was paid to combined effects of quantum mechanics and confinement. A suite of analytical and numerical tools tailored to the specific inquiry has been developed and employed

  14. Inflationary trispectrum from graviton exchange

    DEFF Research Database (Denmark)

    Seery, David; Sloth, Martin Snoager; Vernizzi, Filippo

    2009-01-01

    We compute the connected four-point correlation function of the primordial curvature perturbation generated during inflation with standard kinetic terms, where the correlation is established via exchange of a graviton between two pairs of scalar fluctuations. Any such correlation yields a contrib......We compute the connected four-point correlation function of the primordial curvature perturbation generated during inflation with standard kinetic terms, where the correlation is established via exchange of a graviton between two pairs of scalar fluctuations. Any such correlation yields...

  15. Proton exchange membrane fuel cells

    CERN Document Server

    Qi, Zhigang

    2013-01-01

    Preface Proton Exchange Membrane Fuel CellsFuel CellsTypes of Fuel CellsAdvantages of Fuel CellsProton Exchange Membrane Fuel CellsMembraneCatalystCatalyst LayerGas Diffusion MediumMicroporous LayerMembrane Electrode AssemblyPlateSingle CellStackSystemCell Voltage Monitoring Module (CVM)Fuel Supply Module (FSM)Air Supply Module (ASM)Exhaust Management Module (EMM)Heat Management Module (HMM)Water Management Module (WMM)Internal Power Supply Module (IPM)Power Conditioning Module (PCM)Communications Module (COM)Controls Module (CM)SummaryThermodynamics and KineticsTheoretical EfficiencyVoltagePo

  16. Common Knowledge in Email Exchanges

    CERN Document Server

    Sietsma, Floor

    2011-01-01

    We consider a framework in which a group of agents communicates by means of emails, with the possibility of replies, forwards and blind carbon copies (BCC). We study the epistemic consequences of such email exchanges by introducing an appropriate epistemic language and semantics. This allows us to determine when a group of agents acquires common knowledge of the formula expressing that an email was sent. We also show that in our framework from the epistemic point of view the BCC feature of emails cannot be simulated using messages without BCC recipients. Finally, we clarify the notion of a causal relationship between emails using the concept of properly terminating email exchanges.

  17. The Commodity and its Exchange

    DEFF Research Database (Denmark)

    Høst, Jeppe Engset

    2015-01-01

    This chapter examines fishing quota as a commodity in both a conceptual perspective and through ethnographic examples. Inspired by Marx’s ideas of the commodity, use-value, exchange-value, and ground rent, the chapter combines a theoretical approach with ethnographic material. The different aspects...... and the value of the quota are examined through the concrete exchange of fishing rights, and it is explained why quota trade can give rise to speculation and monopolies. In the final part of the chapter, it is argued that the value of transferable fishing quotas rely on a social relation between owners...

  18. Evaluating China's Exchange Rate Regime

    Institute of Scientific and Technical Information of China (English)

    Charlie Xiao Feng

    2008-01-01

    @@ In 1994 China established a de facto currency peg.1 The dollar-RMB exchange rate was fixed at 8.28.The People's Bank of China(PBC) allowed the rate a narrow band of around .01 to .02 percent in which it could shift daily.The exchange rate program did not become newsworthy until U.S.Treasury Secretary John Snow's visit in 2003.In fact as a study by Frankel and Wei (2007)showed, the RMB's forward was actually selling at a discount against the dollar prior to Secretary Snow's visit to China and his subsequent report, signaling that investors were anticipating RMB depreciation.

  19. CHANGES IN EXCHANGE RATE REGIMES

    Directory of Open Access Journals (Sweden)

    Carmen SANDU (TODERASCU

    2014-06-01

    Full Text Available The experience of recentyears showsthat it hasa fundamentalroleformation mechanismof the exchange rateinmacroeconomic stabilization. Global economiccrises, oil shockshave shownthe difficultyoffloatingsustainabilitybyparticipants in the system. EuropeanMonetary System, focused onconcertedfloatingcurrenciestoECU, was formedunder the conditionsin which somecountries have adoptedregional monetaryarrangements(EU countries, with suchbasescurrencyregimeshybridthat combinesspecific mechanismsto those offixedratefree floating. This paperaims to demonstratethe important role thatithasthe choice ofexchange rateregimeas abasic elementin thefoundationofmacroeconomic stabilizationinstruments. Consideredan expression of thestateof the domestic economyandinternationalcompetitiveness, the exchange rate is determined bya complex set ofexternal factorsorinternalstabilityisa prerequisite forthe crisis.

  20. Interaction of neutral atoms and plasma turbulence in the tokamak edge region

    OpenAIRE

    Wersal, Christoph; Ricci, Paolo; Jorge, Rogério; Morales, Jorge; Paruta, Paola; Riva, Fabio

    2016-01-01

    A novel first-principles self-consistent model that couples plasma and neutral atom physics suitable for the simulation of turbulent plasma behaviour in the tokamak edge region has been developed and implemented in the GBS code. While the plasma is modelled by the drift-reduced two fluid Braginskii equations, a kinetic model is used for the neutrals, valid in short and in long mean free path scenarios. The model includes ionization, charge-exchange, recombination, and elastic collisional proc...

  1. A role for eisosomes in maintenance of plasma membrane phosphoinositide levels

    OpenAIRE

    Fröhlich, Florian; Christiano, Romain; Olson, Daniel K.; Alcazar-Roman, Abel; DeCamilli, Pietro; Walther, Tobias C

    2014-01-01

    The plasma membrane delineates the cell and mediates its communication and material exchange with the environment. Many processes of the plasma membrane occur through interactions of proteins with phosphatidylinositol(4,5)-bisphosphate (PI(4,5)P2), which is highly enriched in this membrane and is a key determinant of its identity. Eisosomes function in lateral organization of the plasma membrane, but the molecular function of their major protein subunits, the BAR domain–containing proteins Pi...

  2. Nonlinear plasma wave in magnetized plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Bulanov, Sergei V. [Kansai Photon Science Institute, JAEA, Kizugawa, Kyoto 619-0215 (Japan); Prokhorov Institute of General Physics, Russian Academy of Sciences, Moscow 119991 (Russian Federation); Moscow Institute of Physics and Technology, Dolgoprudny, Moscow region 141700 (Russian Federation); Esirkepov, Timur Zh.; Kando, Masaki; Koga, James K. [Kansai Photon Science Institute, JAEA, Kizugawa, Kyoto 619-0215 (Japan); Hosokai, Tomonao; Zhidkov, Alexei G. [Photon Pioneers Center, Osaka University, 2-8 Yamadaoka, Suita, Osaka 565-0871 (Japan); Japan Science and Technology Agency, CREST, 2-1, Yamadaoka, Suita, Osaka 565-0871 (Japan); Kodama, Ryosuke [Photon Pioneers Center, Osaka University, 2-8 Yamadaoka, Suita, Osaka 565-0871 (Japan); Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2013-08-15

    Nonlinear axisymmetric cylindrical plasma oscillations in magnetized collisionless plasmas are a model for the electron fluid collapse on the axis behind an ultrashort relativisically intense laser pulse exciting a plasma wake wave. We present an analytical description of the strongly nonlinear oscillations showing that the magnetic field prevents closing of the cavity formed behind the laser pulse. This effect is demonstrated with 3D PIC simulations of the laser-plasma interaction. An analysis of the betatron oscillations of fast electrons in the presence of the magnetic field reveals a characteristic “Four-Ray Star” pattern.

  3. Elements of plasma technology

    CERN Document Server

    Wong, Chiow San

    2016-01-01

    This book presents some fundamental aspects of plasma technology that are important for beginners interested to start research in the area of plasma technology . These include the properties of plasma, methods of plasma generation and basic plasma diagnostic techniques. It also discusses several low cost plasma devices, including pulsed plasma sources such as plasma focus, pulsed capillary discharge, vacuum spark and exploding wire; as well as low temperature plasmas such as glow discharge and dielectric barrier discharge which the authors believe may have potential applications in industry. The treatments are experimental rather than theoretical, although some theoretical background is provided where appropriate. The principles of operation of these devices are also reviewed and discussed.

  4. Binary collision rates of relativistic thermal plasmas. I Theoretical framework

    Science.gov (United States)

    Dermer, C. D.

    1985-01-01

    Binary collision rates for arbitrary scattering cross sections are derived in the case of a beam of particles interacting with a Maxwell-Boltzmann (MB) plasma, or in the case of two MB plasmas interacting at generally different temperatures. The expressions are valid for all beam energies and plasma temperatures, from the nonrelativistic to the extreme relativistic limits. The calculated quantities include the reaction rate, the energy exchange rate, and the average rate of change of the squared transverse momentum component of a monoenergetic particle beam as a result of scatterings with particles of a MB plasma. Results are specialized to elastic scattering processes, two-temperature reaction rates, or the cold plasma limit, reproducing previous work.

  5. Inertial Electrostatic Confinement (IEC) Fusion using Helicon Injected Plasma Source

    Science.gov (United States)

    Miley, George; Ahern, Drew; Bowman, Jaerd

    2016-10-01

    The use of an external plasma source with the IEC has the advantage that the background pressure in the IEC chamber can be low. This then enables a deep potential well formation for ion confinement. Also unit efficiency is increase due to minimization of ion losses through charge exchange. This technique is under study experimentally for use in a plasma jet propulsion unit and as an IEC type neutron source. Current work has studied the effect of locating the IEC grids off-center in the vacuum chamber, near the plasma entrance from the Helicon. With double grids, the relative potentials employed are also key factors in device performance. Electron emitters are added for space charge neutralization in the case of plasma jet propulsion. Plasma simulations are used to supplement the experiments. Specifically, the electric field and the magnetic field effects on energetic ion trajectories are examined for varying configurations. Funding by NASA, Air Force Research Lab and NPL Associates.

  6. Functional expression of Na-Ca exchanger clones measured with the fluorescent Ca(2+)-indicating dye fluo-3.

    Science.gov (United States)

    Schnetkamp, P P

    1996-01-01

    The process of Ca2+ homeostasis is of prime importance to all cells because of the ubiquitous role of cytoplasmic Ca2+ as an intracellular messenger and the cytotoxicity of sustained elevated cytosolic Ca2+ concentrations. Two classes of plasma membrane proteins are responsible for maintaining cytosolic free Ca2+ in the submicromolar range against a very large electrochemical Ca2+ gradient across the plasma membrane, the ATP-driven Ca2+ pump and Na-Ca exchangers. Two types of Na-Ca exchangers are known, the 3Na:1Ca exchangers found in heart, brain, kidney, and most other tissues and the 4Na:1Ca+ 1K exchanger found in retinal rod and cone photoreceptors. Functional expression of Na-Ca(/K) exchangers is most often measured as 45Ca uptake in Na(+)-loaded cells or as Na-Ca exchange currents with the giant excised patch technique. In this study, two functional assays used to detect expression of the bovine heart Na-Ca exchanger in CHO cells are described. Both assays are based on measurements of cytosolic free Ca2+ with the fluorescent Ca(2+)-indicating dye fluo-3 and should be equally applicable in the study of functional expression of both Na-Ca and Na-Ca/K exchanger clones.

  7. Nonadiabatic exchange dynamics during adiabatic frequency sweeps.

    Science.gov (United States)

    Barbara, Thomas M

    2016-04-01

    A Bloch equation analysis that includes relaxation and exchange effects during an adiabatic frequency swept pulse is presented. For a large class of sweeps, relaxation can be incorporated using simple first order perturbation theory. For anisochronous exchange, new expressions are derived for exchange augmented rotating frame relaxation. For isochronous exchange between sites with distinct relaxation rate constants outside the extreme narrowing limit, simple criteria for adiabatic exchange are derived and demonstrate that frequency sweeps commonly in use may not be adiabatic with regard to exchange unless the exchange rates are much larger than the relaxation rates. Otherwise, accurate assessment of the sensitivity to exchange dynamics will require numerical integration of the rate equations. Examples of this situation are given for experimentally relevant parameters believed to hold for in-vivo tissue. These results are of significance in the study of exchange induced contrast in magnetic resonance imaging.

  8. Reviews of plasma physics

    CERN Document Server

    2008-01-01

    "Reviews of Plasma Physics Volume 24," edited by V.D. Shafranov, presents two reviews from the cutting-edge of Russian plasma physics research. The first review by V.A. Rozhansky devoted to the mechanisms of transverse conductivity and generation of self-consistent electric fields in strongly ionized magnetized plasma. The second review by O.G. Bakunin considers numerous aspects of turbulent transport in plasma and fluids. This review is focused on scaling arguments for describing anomalous diffusion in the presence of complex structures. These topics are especially important for fusion plasma research, plasma astrophysics, discharge physics, and turbulence

  9. Reviews of plasma physics

    Energy Technology Data Exchange (ETDEWEB)

    Shafranov, Vitalii Dmitrievich (ed.); Bakunin, Oleg G. (comps.) [Rossijskij Nauchnyj Tsentr ' ' Kurchatovskij Inst.' ' , Moscow (Russian Federation). Nuclear Fusion Inst.; Rozhansky, V. [St. Petersburg State Polytechnical Univ. (Russian Federation)

    2008-07-01

    Reviews of Plasma Physics Volume 24, edited by V.D. Shafranov, presents two reviews from the cutting-edge of Russian plasma physics research. The first review by V.A. Rozhansky devoted to the mechanisms of transverse conductivity and generation of self-consistent electric fields in strongly ionized magnetized plasma. The second review by O.G. Bakunin considers numerous aspects of turbulent transport in plasma and fluids. This review is focused on scaling arguments for describing anomalous diffusion in the presence of complex structures. These topics are especially important for fusion plasma research, plasma astrophysics, discharge physics, and turbulence (orig.)

  10. Energy Exchange NASA Opening Plenary

    Science.gov (United States)

    Marrs, Rick

    2017-01-01

    Rick Marrs, Deputy Assistant Administrator Office of Strategic Infrastructure NASA Headquarters will be speaking during the 2017 Energy Exchange opening plenary. His presentation showcases the NASA mission, sustainability at NASA, NASA's strategic Sustainability Performance Plan, Existing PV Partnerships, and NASA funded Solar Initiatives at KSC.

  11. Knowledge Exchange with Sistema Scotland

    Science.gov (United States)

    Allan, Julie; Moran, Nikki; Duffy, Celia; Loening, Gica

    2010-01-01

    This paper reports on a knowledge exchange project, funded by the Scottish Funding Council and undertaken by a group of researchers from three higher education institutions in Scotland and the project partner, Sistema Scotland. This newly established charity is attempting to implement a major programme of social change, developed in Venezuela,…

  12. The Commodity and its Exchange

    DEFF Research Database (Denmark)

    Høst, Jeppe Engset

    2015-01-01

    and the value of the quota are examined through the concrete exchange of fishing rights, and it is explained why quota trade can give rise to speculation and monopolies. In the final part of the chapter, it is argued that the value of transferable fishing quotas rely on a social relation between owners...... and nonowners of quota, as a form of monopoly rent....

  13. Fragmentary model of exchange interactions

    CERN Document Server

    Kotov, V M

    2000-01-01

    This article makes attempt to refusal from using neutrino for explanation continuous distribution of beta particle energy by conversion to characteristic exchange interaction particles in nucleolus. It is taking formulation for nuclear position with many different fragments. It is computing half-value period of spontaneous fission of heavy nucleolus. (author)

  14. "Bottle-Brush" Heat Exchanger

    Science.gov (United States)

    Tward, E.; Gatewood, J. R.

    1982-01-01

    Heat exchanger consists of a metal tube with wires extending inward from wall. Conduction of heat along wires improves heat transfer to gas or other filling. Fluid is heated throughout the cross section of tube. Suggested applications are refrigerators, heat engines, thermal instrumentation, and heat switches.

  15. Milk fouling in heat exchangers.

    NARCIS (Netherlands)

    Jeurnink, Th.J.M.

    1996-01-01

    The mechanisms of fouling of heat exchangers by milk were studied. Two major fouling mechanisms were indentified during the heat treatment of milk: (i) the formation and the subsequent deposition of activated serum protein molecules as a result of the heat denaturation; (ii) the precipitation of cal

  16. Baltic Exchange teper v Tallinne

    Index Scriptorium Estoniae

    2007-01-01

    Viimane osa merekonteineritesse kokkupakitud Londoni laevandus- ja merebörsi Baltic Exchange'i endise peakorteri detailidest jõudis 2007. a. juunis Tallinna. Hoone detailid ostnud ärimehed Heiti Hääl ja Eerik-Niiles Kross plaanivad leida hoonele koha Tallinna kesklinnas. E.-N. Krossi kommentaar

  17. The Commodity and its Exchange

    DEFF Research Database (Denmark)

    Høst, Jeppe Engset

    2015-01-01

    This chapter examines fishing quota as a commodity in both a conceptual perspective and through ethnographic examples. Inspired by Marx’s ideas of the commodity, use-value, exchange-value, and ground rent, the chapter combines a theoretical approach with ethnographic material. The different aspec...

  18. SPECTRAL ANALYSIS OF EXCHANGE RATES

    Directory of Open Access Journals (Sweden)

    ALEŠA LOTRIČ DOLINAR

    2013-06-01

    Full Text Available Using spectral analysis is very common in technical areas but rather unusual in economics and finance, where ARIMA and GARCH modeling are much more in use. To show that spectral analysis can be useful in determining hidden periodic components for high-frequency finance data as well, we use the example of foreign exchange rates

  19. Knowledge Exchange with Sistema Scotland

    Science.gov (United States)

    Allan, Julie; Moran, Nikki; Duffy, Celia; Loening, Gica

    2010-01-01

    This paper reports on a knowledge exchange project, funded by the Scottish Funding Council and undertaken by a group of researchers from three higher education institutions in Scotland and the project partner, Sistema Scotland. This newly established charity is attempting to implement a major programme of social change, developed in Venezuela,…

  20. Common knowledge in email exchanges

    NARCIS (Netherlands)

    Sietsma, F.; Apt, K.R.; van Eijck, D.J.N.; Verbrugge, R.

    2011-01-01

    We consider a framework in which a group of agents communicates by means of emails, with the possibility of replies, forwards and blind carbon copies (BCC). We study the epistemic consequences of such email exchanges by introducing an appropriate epistemic language and semantics. This allows us to

  1. Extracellular superoxide dismutase of boar seminal plasma.

    Science.gov (United States)

    Kowalowka, M; Wysocki, P; Fraser, L; Strzezek, J

    2008-08-01

    Superoxide dismutase (SOD) is an enzymatic component of the antioxidant defense system that protects spermatozoa by catalysing the dismutation of superoxide anions to hydrogen peroxide and oxygen. Age and season effects on SOD activity in the seminal plasma were measured in boars at the onset of 8 months through a 35-month period. It was found that age-related changes in SOD activity in the seminal plasma were markedly higher in boars less than 2 years of age. However, it appeared that SOD activity was established at the early sexual maturity age (8-12 months). There were variations in SOD activity throughout the season, being significantly higher in spring and autumn than in summer. A secretory extracellular form of SOD (EC-SOD) was purified to homogeneity (350-fold) from boar seminal plasma, using a three-step purification protocol (affinity chromatography followed by ion exchange and ceramic hydroxyapatite chromatography). The molecular properties and specificity of SOD (molecular mass, isoelectric point, optimum pH, thermostability and susceptibility to inhibitors) confirmed that the purified enzyme is an extracellular form of Cu/Zn-superoxide dismutase occurring in boar seminal plasma. The results of this study indicate that EC-SOD is an important antioxidant enzyme of boar seminal plasma, which plays an important physiological role in counteracting oxidative stress in spermatozoa.

  2. Foreign Exchange Reserves: Bangladesh Perspective

    Directory of Open Access Journals (Sweden)

    Md Zahangir Alam

    2013-10-01

    Full Text Available This study is about foreign exchangereserves of Bangladesh. The mainpurpose of this study is to the influence of exchange rates on foreign exchangereserves to the Bangladesh context.  Both the primary and secondary data has been used inthis study. The primary data has been collected through a structuredquestionnaire from 50 respondents. The secondary data, namely Bangladeshforeign exchange reserves (FER, Bangladesh current account balance (CAB,Bangladesh capital andfinancial account balance (CFAB, and BDT/USD exchange rates (ER.  This study covers yearly data from July 01,1996 to June 30, 2005 and quarterly data from July 01, 2005 to June 30, 2012. Findingsof this study shows that out of the selected 16 factors affecting foreignexchange reserves, exchange rates occupy the first position, weighted averagescore (WAS being 4.56. Foreign exchange reserves (FER and current accountbalance (CAB have increased by 502.9087% and 1451.218%,whereas capital and financial account (CFAB has decreased by -649.024% on June30, 2012 compared to June 30, 1997. The influence of other factors heldconstant, as ER changes by 285.6894 units due to one unit change in FER, onaverage in the same direction which represents that ER has positive effect on theFER and this relationship is statistically significant.  62.1526 percentof the variation in FER is explained by ER. The outcomes of Breusch-Godfrey test (LM test, ARCHtest, and the Normality test are that there is a serial correlation among residuals, the variance of residuals is notconstant, and the residuals are not normally distributed.

  3. Compact Ceramic Microchannel Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Lewinsohn, Charles [Ceramatec, Inc., Salt Lake City, UT (United States)

    2016-10-31

    The objective of the proposed work was to demonstrate the feasibility of a step change in power plant efficiency at a commercially viable cost, by obtaining performance data for prototype, compact, ceramic microchannel heat exchangers. By performing the tasks described in the initial proposal, all of the milestones were met. The work performed will advance the technology from Technology Readiness Level 3 (TRL 3) to Technology Readiness Level 4 (TRL 4) and validate the potential of using these heat exchangers for enabling high efficiency solid oxide fuel cell (SOFC) or high-temperature turbine-based power plants. The attached report will describe how this objective was met. In collaboration with The Colorado School of Mines (CSM), specifications were developed for a high temperature heat exchanger for three commercial microturbines. Microturbines were selected because they are a more mature commercial technology than SOFC, they are a low-volume and high-value target for market entry of high-temperature heat exchangers, and they are essentially scaled-down versions of turbines used in utility-scale power plants. Using these specifications, microchannel dimensions were selected to meet the performance requirements. Ceramic plates were fabricated with microchannels of these dimensions. The plates were tested at room temperature and elevated temperature. Plates were joined together to make modular, heat exchanger stacks that were tested at a variety of temperatures and flow rates. Although gas flow rates equivalent to those in microturbines could not be achieved in the laboratory environment, the results showed expected efficiencies, robust operation under significant temperature gradients at high temperature, and the ability to cycle the stacks. Details of the methods and results are presented in this final report.

  4. Hot plasma dielectric tensor

    NARCIS (Netherlands)

    Westerhof, E.

    1996-01-01

    The hot plasma dielectric tensor is discussed in its various approximations. Collisionless cyclotron resonant damping and ion/electron Bernstein waves are discussed to exemplify the significance of a kinetic description of plasma waves.

  5. Special issue: Plasma Conversion

    NARCIS (Netherlands)

    Nozaki, T.; Bogaerts, A.; Tu, X.; van de Sanden, M. C. M.

    2017-01-01

    With growing concern of energy and environmental issues, the combination of plasma and heterogeneous catalysts receives special attention in greenhouse gas conversion, nitrogen fixation and hydrocarbon chemistry. Plasma gas conversion driven by renewable electricity is particularly important for the

  6. RMB Exchange Market Pressure and Central Bank Exchange Market Intervention

    Institute of Scientific and Technical Information of China (English)

    Xiaohui Liu; Jing Zhang

    2009-01-01

    The present paper uses the model-dependent and the model-independent approach to measure the RMB exchange market pressure (EMP) and the central bank's intervention using monthly data from January 1999 to June 2008. It is determined that the RMB has been under great appreciation pressure over the past decade. However, the pressure has been weakening since 2005. The two approaches provide significantly different results in terms of the estimated RMB EMP indices and the estimated central bank's interventions. The differences may lead to different predictions of potential currency crises. According to the estimation of the RMB EMP, and based on the model-independent approach, the paper shows that China has been under threat of an appreciation currency crisis since 2008. Therefore, China should adopt a more flexible exchange rate regime to prevent a potential crisis.

  7. The charge exchange recombination diagnostic system on the DIII-D tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Gohil, P.; Burrell, K.H.; Groebner, R.J.; Kim, J.; Martin, W.C.; McKee, E.L.; Seraydarian, R.P.

    1991-11-01

    The charge exchange recombination (CER) diagnostic system on the DIII-D tokamak is used to make spatially and temporally resolved measurements of the ion temperature and toroidal and poloidal rotation velocities. This is performed through visible spectroscopic measurements of the Doppler broadened and Doppler shifted HE II 468.6 nm, the CVI 529.1 nm, and the BV 494.5 nm spectral lines which have been excited by charge exchange recombination interactions between the fully stripped ions and the neutral atoms from the heating beams. The plasma viewing optics comprises 32 viewing chords spanning a typical plasma minor radius of 63 cm across the midplane, of which 15 spatial chords span 4.2 cm at the plasma edge just within the separatrix and provide a chord-to-chord spatial resolution of 0.3 cm. Fast camera readout electronics can provide a temporal resolution of 260 {mu}s per time slice, but the effective minimum integration time, at present, is 1 ms which is limited by the detected photon flux from the plasma and the decay times of the phosphors used on the multichannel plate image intensifiers. Significant changes in the edge plasma radial electric field at the L-H transition have been observed, as determined from the CER measurements, and these results are being extensively compared to theories which consider the effects of sheared electric fields on plasma turbulence. 13 refs., 10 figs.

  8. Microwave Argon Plasma Torch

    Science.gov (United States)

    2013-07-01

    an electron-ion pair in the discharge. Fig. 2. EEDF is non - Maxwellian and changes along the plasma column The electron–neutral collision...plasma radius. Even at atmospheric pressure the EEDF is non - Maxwellian and it is changing along the plasma column. ...18 31st ICPIG, July 14-19, 2013, Granada, Spain EEDF usually strongly differs from Maxwellian and chages along the plasma column (this is

  9. Introduction to Plasma Physics

    Science.gov (United States)

    Gurnett, Donald A.; Bhattacharjee, Amitava

    2017-03-01

    Preface; 1. Introduction; 2. Characteristic parameters of a plasma; 3. Single particle motions; 4. Waves in a cold plasma; 5. Kinetic theory and the moment equations; 6. Magnetohydrodynamics; 7. MHD equilibria and stability; 8. Discontinuities and shock waves; 9. Electrostatic waves in a hot unmagnetized plasma; 10. Waves in a hot magnetized plasma; 11. Nonlinear effects; 12. Collisional processes; Appendix A. Symbols; Appendix B. Useful trigonometric identities; Appendix C. Vector differential operators; Appendix D. Vector calculus identities; Index.

  10. Plasma physics an introduction

    CERN Document Server

    Fitzpatrick, Richard

    2014-01-01

    Plasma Physics: An Introduction is based on a series of university course lectures by a leading name in the field, and thoroughly covers the physics of the fourth state of matter. This book looks at non-relativistic, fully ionized, nondegenerate, quasi-neutral, and weakly coupled plasma. Intended for the student market, the text provides a concise and cohesive introduction to plasma physics theory, and offers a solid foundation for students wishing to take higher level courses in plasma physics.

  11. Quantum kinetic theories in degenerate plasmas

    Science.gov (United States)

    Brodin, Gert; Ekman, Robin; Zamanian, Jens

    2017-01-01

    In this review we give an overview of the recent work on quantum kinetic theories of plasmas. We focus, in particular, on the case where the electrons are fully degenerate. For such systems, perturbation methods using the distribution function can be problematic. Instead we present a model that considers the dynamics of the Fermi surface. The advantage of this model is that, even though the value of the distribution function can be greatly perturbed outside the equilibrium Fermi surface, deformation of the Fermi surface is small up to very large amplitudes. Next, we investigate the short-scale dynamics for which the Wigner-Moyal equation replaces the Vlasov equation. In particular, we study wave-particle interaction, and deduce that new types of wave damping can occur due to the simultaneous absorption (or emission) of multiple wave quanta. Finally, we consider exchange effects within a quantum kinetic formalism to find a model that is more accurate than those using exchange potentials from density functional theory. We deduce the exchange corrections to the dispersion relations for Langmuir and ion-acoustic waves. In comparison to results based on exchange potentials deduced from density functional theory we find that the latter models are reasonably accurate for Langmuir waves, but rather inaccurate for ion acoustic waves.

  12. Plasma membrane ATPases

    DEFF Research Database (Denmark)

    Palmgren, Michael Broberg; Bækgaard, Lone; Lopez Marques, Rosa Laura

    2011-01-01

    The plasma membrane separates the cellular contents from the surrounding environment. Nutrients must enter through the plasma membrane in order to reach the cell interior, and toxic metabolites and several ions leave the cell by traveling across the same barrier. Biological pumps in the plasma me...

  13. Plasma in dentistry

    OpenAIRE

    Cha, Seunghee; Park, Young-Seok

    2014-01-01

    This review describes the contemporary aspects of plasma application in dentistry. Previous studies on plasma applications were classified into two categories, surface treatment and direct applications, and were reviewed, respectively according to the approach. The current review discussed modification of dental implant surface, enhancing of adhesive qualities, enhancing of polymerization, surface coating and plasma cleaning under the topics of surface treatment. Microbicidal activities, deco...

  14. The Plasma Universe

    Science.gov (United States)

    Suplee, Curt

    2009-09-01

    Preface; 1. The fourth state of matter; 2. The music and dance of plasmas; 3. The Sun-Earth connection; 4. Bringing the Sun to Earth: the story of controlled thermonuclear fusion; 5. The cosmic plasma theater: galaxies, stars, and accretion disks; 6. Putting plasmas to work; Index.

  15. Application of explosive welding to heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Arthur, G.

    1983-10-01

    The subject is discussed under the headings: advantages of explosive welding; principle of explosive welding; explosive welding of tubes; metallurgy of explosive welds (micrographs; microhardness); tubular heat exchangers; plugging; sleeving; retubing; construction of new heat exchangers; thermal sleeves.

  16. Foreign Exchange Exposure of Korean Firms

    National Research Council Canada - National Science Library

    Ji-Seon Kim

    2002-01-01

    The purpose of this study is to examine the relationship between the movements of exchange rate and value of Korean firms, so-called foreign exchange rate exposure using newly devised model to find the strong evidence...

  17. A core alternative[Heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, R.H. [Chart Heat Exchangers, Wisconsin (United States)

    2001-09-01

    The development of the efficient Core-in-kettle heat exchangers by Chart Heat Exchangers as an alternative to shell and tube exchangers is reported, and its use as condensers and reboilers in ethylene plants and refrigerant condensers and chillers in natural gas processing and liquid natural gas (LNG) plants are discussed. The novel technology is described with details given of the replacement of the tube bundle with a Chart brazed aluminium plate-fin heat exchanger core, the operation of the exchanger, the savings achieved by installing these heat exchangers in new or existing plants, and Core-in-Kettle retrofits of existing shell and tube heat exchangers. The limitations of the use of Core-in-Kettle heat exchangers to clean fluids typical of hydrocarbon processing, and temperature and pressure limitations are noted.

  18. A simple nonlocal model for exchange.

    Science.gov (United States)

    Janesko, Benjamin G

    2009-12-21

    This work presents a new nonlocal model for the exchange energy density. The model is obtained from the product of the Kohn-Sham one-particle density matrix used to construct exact [Hartree-Fock-like (HF)] exchange, and an approximate density matrix used to construct local spin-density approximation (LSDA) exchange. The proposed exchange energy density has useful formal properties, including correct spin and coordinate scaling and the correct uniform limit. It can readily be evaluated in finite basis sets, with a computational scaling intermediate between HF exchange and semilocal quantities such as the noninteracting kinetic energy density. Applications to representative systems indicate that its properties are typically intermediate between HF and LSDA exchange, and often similar to global hybrids of HF and LSDA exchange. The model is proposed as a novel "Rung 3.5" ingredient for constructing approximate exchange-correlation functionals.

  19. Flexible Exchange of Farming Device Data

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Pedersen, Torben Bach

    2011-01-01

    A new trend in the farming business is to replace conventional farming devices with computerized farming devices. Accordingly, numerous computer-based farming devices for logging, processing and exchanging data have recently been installed on moving farm machinery such as tractors. The exchange...... of data generally takes place between the devices and farming systems, mostly installed at the premises of farmers, contractors, advisory services etc. In most cases, data exchange is based on farming data exchange standards and is bi-directional. Bi-directional data exchange allows different devices...... and systems to exchange data based on a predefined set of rules. In consequence, many hand-coded data exchange solutions have been developed in the farming business. Although efforts regarding incorporating data exchange standards have been made, their actual usage so far has been limited, due to the fact...

  20. The RMB Exchange Rate Keeps Increasing

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    @@ In July 2005, the People's Bank of China officially announced that it would adopt a manageable floating exchange rate, adjusted according to a basket of currencies based on market supply and demand. On that day, the exchange rate of the RMB to the U.S. Dollar increased by 21 percent, and since then the RMB exchange rate has gradually turned to a more flexible exchange rate convention, rather than focusing on the Dollar only.

  1. Exchange Rate Volatility in BRICS Countries

    OpenAIRE

    2012-01-01

    This paper measures the impact of bilateral exchange rates, the world agricultural GDP and third-country exchange rate volatilities (Yen/USD and Euro/USD) on the BRICS agricultural exports using a vector autoregressive (VAR) model. Two measures of volatility are used: the standard deviation and the coefficient of variation of the rates of change of the real exchange rates. We found that most variables are integrated of order two except the third-country exchange rate volatilities which are st...

  2. Wealth Distributions in Asset Exchange Models

    CERN Document Server

    Krapivsky, P L

    2010-01-01

    How do individuals accumulate wealth as they interact economically? We outline the consequences of a simple microscopic model in which repeated pairwise exchanges of assets between individuals build the wealth distribution of a population. This distribution is determined for generic exchange rules --- transactions that involve a fixed amount or a fixed fraction of individual wealth, as well as random or greedy exchanges. In greedy multiplicative exchange, a continuously evolving power law wealth distribution arises, a feature that qualitatively mimics empirical observations.

  3. Groundwater–Surface Water Exchange

    DEFF Research Database (Denmark)

    Karan, Sachin

    The exchange of groundwater-surface water has been invetigated in the western part of Denmark. Holtum AA provides the framework for all the performed investigations. Several methods are used, primarily eld based measurements ombined with numerical models to achieve insight to the governing...... processes of interaction between groundwater and surface water. By using heat as a tracer it has been possible to use temperature directly as calibrationtargets in a groundwater and heat transport model. Thus, it is possible to use heat investigate the change in groundwater discharge in dynamic conditions...... by using simple temperature devices along a stream to delineate the areas of interest in regard to GW{SW exchange. Thus, at several locations in a stream a temperature data logger was placed in the water column and right at the streambed-water interface. By looking at the correlation of streambed...

  4. Inflationary trispectrum from graviton exchange

    CERN Document Server

    Seery, David; Vernizzi, Filippo

    2008-01-01

    We compute the connected four-point correlation function of the primordial curvature perturbation generated during inflation with standard kinetic terms, where the correlation is established via exchange of a graviton between two pairs of scalar fluctuations. Any such correlation yields a contribution to the scalar trispectrum of the order of the tensor to scalar ratio r. This contribution is numerically one order of magnitude larger than the one previously calculated on the basis of scalar perturbations interacting at a point and satisfies a simple relation in the limit where the momentum of the graviton which is exchanged becomes much smaller than the external momenta. We conclude that the total non-linearity parameter generated by single-field models of slow-roll inflation is at maximum tauNL ~ r.

  5. Inflationary trispectrum from graviton exchange

    Energy Technology Data Exchange (ETDEWEB)

    Seery, David [Department of Applied Mathematics and Theoretical Physics, Wilberforce Road, Cambridge, CB3 0WA (United Kingdom); Sloth, Martin S. [Department of Physics and Astronomy, University of Aarhus, Ny Munkegade, DK-8000 Aarhus C (Denmark); Vernizzi, Filippo, E-mail: djs61@cam.ac.uk, E-mail: sloth@phys.au.dk, E-mail: filippo.vernizzi@cea.fr [CEA, IPhT, 91191 Gif-sur-Yvette cedex, France CNRS, URA-2306, 91191 Gif-sur-Yvette cedex (France)

    2009-03-15

    We compute the connected four-point correlation function of the primordial curvature perturbation generated during inflation with standard kinetic terms, where the correlation is established via exchange of a graviton between two pairs of scalar fluctuations. Any such correlation yields a contribution to the scalar trispectrum of the order of the tensor to scalar ratio r. This contribution is numerically one order of magnitude larger than the one previously calculated on the basis of scalar perturbations interacting at a point and satisfies a simple relation in the limit where the momentum of the graviton which is exchanged becomes much smaller than the external momenta. We conclude that the total non-linearity parameter generated by single-field models of slow-roll inflation is at maximum |{tau}{sub NL}| {approx} r.

  6. Groundwater–Surface Water Exchange

    DEFF Research Database (Denmark)

    Karan, Sachin

    The exchange of groundwater-surface water has been invetigated in the western part of Denmark. Holtum AA provides the framework for all the performed investigations. Several methods are used, primarily eld based measurements ombined with numerical models to achieve insight to the governing...... processes of interaction between groundwater and surface water. By using heat as a tracer it has been possible to use temperature directly as calibrationtargets in a groundwater and heat transport model. Thus, it is possible to use heat investigate the change in groundwater discharge in dynamic conditions...... by using simple temperature devices along a stream to delineate the areas of interest in regard to GW{SW exchange. Thus, at several locations in a stream a temperature data logger was placed in the water column and right at the streambed-water interface. By looking at the correlation of streambed...

  7. Bistability in radiative heat exchange

    Science.gov (United States)

    Rudakov, V. I.; Ovcharov, V. V.; Prigara, V. P.

    2008-08-01

    The possibility of a bistable regime in systems with radiative heat exchange is theoretically demonstrated for the first time. The transfer characteristics of a radiation-closed stationary system have been calculated, in which the radiator is a blackbody and the absorber is made of a material with the absorptivity sharply increasing in a certain temperature interval. The radiator and absorber are separated by a vacuum gap. The heat exchange between the system and the environment is controlled by varying the flow rate of a heat-transfer agent cooling the absorber. The output parameter of a bistable system is the absorber temperature, while the input parameter can be either the radiator temperature or the heat-transfer agent flow rate. Depending on the choice of the input parameter, the transfer characteristic of the system is either represented by a usual S-like curve or has an inverted shape.

  8. Electrically controlled cesium ion exchange

    Energy Technology Data Exchange (ETDEWEB)

    Lilga, M. [Pacific Northwest Lab., Richland, WA (United States)

    1996-10-01

    Several sites within the DOE complex (Savannah River, Idaho, Oak Ridge and Hanford) have underground storage tanks containing high-level waste resulting from nuclear engineering activities. To facilitate final disposal of the tank waste, it is advantageous to separate and concentrate the radionuclides for final immobilization in a vitrified glass matrix. This task proposes a new approach for radionuclide separation by combining ion exchange (IX) and electrochemistry to provide a selective and economic separation method.

  9. [Biofouling of heat exchange tubes].

    Science.gov (United States)

    Montero, F; Pintado, J L

    1994-01-01

    We compared the biofouling behavior of different materials (admiralty brass, stainless steel, and titanium) commonly used to construct heat exchangers in thermoelectric plants. The incidence of film formation on the loss of heat during transference was assessed, and analyzed in terms of plant efficiency and corrosion, both general and localized development. Our results showed that the resistance of titanium and stainless steel to corrosion was similar, and much better than that of admiralty brass. Biofouling, however, was higher in the first two materials.

  10. Improved Ceramic for Heat Exchangers

    Science.gov (United States)

    Herbell, T. P.; Rauch, H. W.; Mccreeght, L. R.

    1982-01-01

    Most promising composition developed in investigation consisted of mixed oxides described generically as ZrMAS. Has been commercially designated as GE-7808. Material was obtained from low-cost clay/talc mixture. Overall assessment of ZrMAS indicates it is a viable candidate for heat-exchanger application in automotive gas-turbine engines and possibly other areas that require dielectric materials of moderate refractoriness, good corrosion resistance, and excellent thermal-shock resistance.

  11. Value-Added Exchange Rates

    OpenAIRE

    Rudolfs Bems; Robert C. Johnson

    2012-01-01

    This paper updates the conceptual foundations for measuring real effective exchange rates (REERs) to allow for vertical specialization in trade. We derive a value-added REER describing how demand for the value added that a country produces changes as the price of its value added changes relative to competitors. We then compute this index for 42 countries from 1970-2009 using trade measured in value added terms and GDP deflators. There are substantial differences between value-added and conven...

  12. On forecasting Exchange Rate Volatility.

    OpenAIRE

    Hafner, Christian

    2003-01-01

    In an efficient market, foreign exchange rates have to guarantee absence of triangular arbitrage. This note shows that the no-arbitrage condition can be exploited for forecasting the volatility of a single rate by using the information contained in the other rates. Linearly transforming the volatility forecasts of a bivariate model is shown to be more efficient than using a univariate model for the cross-rate.

  13. Washi Painting Exchanges Promote Friendship

    Institute of Scientific and Technical Information of China (English)

    Chuan; You

    2014-01-01

    <正>Invited by the Sichuan Provincial People’s Association for Friendship with Foreign Countries(SIFA),a washi painting exchange delegation headed by Umeko Iwai,President of Rainbow Society of Japan,a Hiroshima-based non-profit organization,visited Sichuan Province from November 3 to 5,2013.Rice paper was invented in China in ancient times.When the paper-making

  14. Volatility at Karachi Stock Exchange

    OpenAIRE

    Aslam Farid; Javed Ashraf

    1995-01-01

    Frequent “crashes” of the stock market reported during the year 1994 suggest that the Karachi bourse is rapidly converting into a volatile market. This cannot be viewed as a positive sign for this developing market of South Asia. Though heavy fluctuations in stock prices are not an unusual phenomena and it has been observed at almost all big and small exchanges of the world. Focusing on the reasons for such fluctuations is instructive and likely to have important policy implications. Proponen...

  15. On Multiple Gluon Exchange Webs

    CERN Document Server

    Harley, Mark

    2015-01-01

    I present an overview of the study of infrared singularities through the eikonal approximation and the concept of webs. Our work reveals the interesting structure of an infinite subclass of webs, Multiple Gluon Exchange Webs. We find that they can be expressed as sums of products of functions depending upon only a single cusp angle, spanned by a simple basis of functions, and conjecture that this structure will hold to all orders.

  16. Acoustic streaming with heat exchange

    Science.gov (United States)

    Gubaidullin, A. A.; Pyatkova, A. V.

    2016-10-01

    Acoustic streaming in a cylindrical cavity with heat exchange is numerically investigated. The cavity is filled with air. The boundaries of the cavity are maintained at constant temperature. The features of acoustic streaming manifesting with the decrease in the frequency of vibration in comparison with the resonant frequency are determined. The influence of the nonlinearity of process on acoustic streaming is shown. The nonlinearity is caused by the increase of the vibration amplitude.

  17. A Brisk Year in Chinese Cultural Exchange

    Institute of Scientific and Technical Information of China (English)

    1993-01-01

    CULTURAL Exchange has learned from the Bureaufor Cultural Relations with Foreign Countries ofthe Ministry of Culture that in 1992 China’scultural exchanges made great progress under the policyof reform and opening to the outside world.Some 1,200exchange projects were examined and approved by theMinistry of Culture(800 delegations sent abroad,more

  18. Pharmaceutical Applications of Ion-Exchange Resins

    Science.gov (United States)

    Elder, David

    2005-01-01

    The historical uses of ion-exchanged resins and a summary of the basic chemical principles involved in the ion-exchanged process are discussed. Specific applications of ion-exchange are provided that include drug stabilization, pharmaceutical excipients, taste-masking agents, oral sustained-release products, topical products for local application…

  19. Ion-exchange chromatographic protein refolding

    NARCIS (Netherlands)

    Freydell, E.; Wielen, van der L.; Eppink, M.H.M.; Ottens, M.

    2010-01-01

    The application of ion-exchange (IEX) chromatography to protein refolding (IExR) has been successfully proven, as supported by various studies using different model proteins, ion-exchange media and flow configurations. Ion-exchange refolding offers a relatively high degree of process

  20. 76 FR 22633 - Retail Foreign Exchange Transactions

    Science.gov (United States)

    2011-04-22

    ... exposure to retail forex transactions or any other foreign exchange risk. Section 48.12--Authorization to... Office of the Comptroller of the Currency 12 CFR Part 48 RIN 1557-AD42 Retail Foreign Exchange... engage in off-exchange transactions in foreign currency with retail customers. The proposed rule also...

  1. Neighbourhood Book Exchanges: Localising Information Practices

    Science.gov (United States)

    Webster, Tenny; Gollner, Kathleen; Nathan, Lisa

    2015-01-01

    Introduction: Through this paper we report on an exploratory study into the design and use of neighbourhood book exchanges in North America. We identify dominant media framings of these book exchanges in North America, along with claims made concerning the influence of the exchanges. We compare the media claims with insights from interviews with…

  2. Cryogenic Heat Exchanger with Turbulent Flows

    Science.gov (United States)

    Amrit, Jay; Douay, Christelle; Dubois, Francis; Defresne, Gerard

    2012-01-01

    An evaporator-type cryogenic heat exchanger is designed and built for introducing fluid-solid heat exchange phenomena to undergraduates in a practical and efficient way. The heat exchanger functions at liquid nitrogen temperature and enables cooling of N[subscript 2] and He gases from room temperatures. We present first the experimental results of…

  3. Cryogenic Heat Exchanger with Turbulent Flows

    Science.gov (United States)

    Amrit, Jay; Douay, Christelle; Dubois, Francis; Defresne, Gerard

    2012-01-01

    An evaporator-type cryogenic heat exchanger is designed and built for introducing fluid-solid heat exchange phenomena to undergraduates in a practical and efficient way. The heat exchanger functions at liquid nitrogen temperature and enables cooling of N[subscript 2] and He gases from room temperatures. We present first the experimental results of…

  4. Pressurized bellows flat contact heat exchanger interface

    Science.gov (United States)

    Voss, Fred E. (Inventor); Howell, Harold R. (Inventor); Winkler, Roger V. (Inventor)

    1990-01-01

    Disclosed is an interdigitated plate-type heat exchanger interface. The interface includes a modular interconnect to thermally connect a pair or pairs of plate-type heat exchangers to a second single or multiple plate-type heat exchanger. The modular interconnect comprises a series of parallel, plate-type heat exchangers arranged in pairs to form a slot therebetween. The plate-type heat exchangers of the second heat exchanger insert into the slots of the modular interconnect. Bellows are provided between the pairs of fins of the modular interconnect so that when the bellows are pressurized, they drive the plate-type heat exchangers of the modular interconnect toward one another, thus closing upon the second heat exchanger plates. Each end of the bellows has a part thereof a thin, membrane diaphragm which readily conforms to the contours of the heat exchanger plates of the modular interconnect when the bellows is pressurized. This ensures an even distribution of pressure on the heat exchangers of the modular interconnect thus creating substantially planar contact between the two heat exchangers. The effect of the interface of the present invention is to provide a dry connection between two heat exchangers whereby the rate of heat transfer can be varied by varying the pressure within the bellows.

  5. Ion-exchange chromatographic protein refolding

    NARCIS (Netherlands)

    Freydell, E.; Wielen, van der L.; Eppink, M.H.M.; Ottens, M.

    2010-01-01

    The application of ion-exchange (IEX) chromatography to protein refolding (IExR) has been successfully proven, as supported by various studies using different model proteins, ion-exchange media and flow configurations. Ion-exchange refolding offers a relatively high degree of process intensification

  6. Isotope exchange by Ion Cyclotron Wall Conditioning on JET

    Energy Technology Data Exchange (ETDEWEB)

    Wauters, T., E-mail: t.wauters@fz-juelich.de [Laboratory for Plasma Physics, ERM/KMS, TEC Partner, 1000 Brussels (Belgium); Douai, D.; Kogut, D. [CEA, IRFM, F-13108 St-Paul-Lez-Durance (France); Lyssoivan, A. [Laboratory for Plasma Physics, ERM/KMS, TEC Partner, 1000 Brussels (Belgium); Brezinsek, S. [Forschungszentrum Jülich, Institut für Energie- und Klimaforschung Plasmaphysik, 52425 Jülich (Germany); Belonohy, E. [Max-Planck Institut für Plasmaphysik, 85748 Garching (Germany); Blackman, T. [JET-EFDA, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Bobkov, V. [Max-Planck Institut für Plasmaphysik, 85748 Garching (Germany); Crombé, K. [Laboratory for Plasma Physics, ERM/KMS, TEC Partner, 1000 Brussels (Belgium); Drenik, A. [Jožef Stefan Institute, 1000 Ljubljana (Slovenia); Graham, M. [JET-EFDA, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Joffrin, E. [CEA, IRFM, F-13108 St-Paul-Lez-Durance (France); Lerche, E. [Laboratory for Plasma Physics, ERM/KMS, TEC Partner, 1000 Brussels (Belgium); Loarer, T. [CEA, IRFM, F-13108 St-Paul-Lez-Durance (France); Lomas, P.L.; Mayoral, M.-L.; Monakhov, I. [JET-EFDA, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Oberkofler, M. [Max-Planck Institut für Plasmaphysik, 85748 Garching (Germany); Philipps, V. [Forschungszentrum Jülich, Institut für Energie- und Klimaforschung Plasmaphysik, 52425 Jülich (Germany); Plyusnin, V. [IST, Instituto de Plasmas e Fusão Nuclear, 1049-001 Lisboa (Portugal); and others

    2015-08-15

    The isotopic exchange efficiencies of JET Ion Cyclotron Wall Conditioning (ICWC) discharges produced at ITER half and full field conditions are compared for JET carbon (C) and ITER like wall (ILW). Besides an improved isotope exchange rate on the ILW providing cleaner plasma faster, the main advantage compared to C-wall is a reduction of the ratio of retained discharge gas to removed fuel. Complementing experimental data with discharge modeling shows that long pulses with high (∼240 kW coupled) ICRF power maximizes the wall isotope removal per ICWC pulse. In the pressure range 1–7.5 × 10{sup −3} Pa, this removal reduces with increasing discharge pressure. As most of the wall-released isotopes are evacuated by vacuum pumps in the post discharge phase, duty cycle optimization studies for ICWC on JET-ILW need further consideration. The accessible reservoir by H{sub 2}-ICWC at ITER half field conditions on the JET-ILW preloaded by D{sub 2} tokamak operation is estimated to be 7.3 × 10{sup 22} hydrogenic atoms, and may be exchanged within 400 s of cumulated ICWC discharge time.

  7. Cyclotron waves in plasma

    CERN Document Server

    Lominadze, D G

    2013-01-01

    Cyclotron Waves in Plasma is a four-chapter text that covers the basic physical concepts of the theory of cyclotron waves and cyclotron instabilities, brought about by the existence of steady or alternating plasma currents flowing perpendicular to the magnetic field.This book considers first a wide range of questions associated with the linear theory of cyclotron oscillations in equilibrium plasmas and in electron plasmas in metals and semiconductors. The next chapter deals with the parametric excitation of electron cyclotron oscillations in plasma in an alternating electric field. A chapter f

  8. The magic of knowledge exchange

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    “If you have an apple and I have an apple and we exchange these apples then you and I will still each have one apple. But if you have an idea and I have an idea and we exchange these ideas, then each of us will have two ideas”. (George Bernard Shaw). The CERN Global Network is a new, ideal place for past and present members of the CERN community to share ideas and create new links.   On 29 April, CERN’s Knowledge and Technology Transfer (KTT) Group launched the CERN Global Network, a tool whose aim is to facilitate knowledge exchanges inside and outside CERN. "Among the greatest ambassadors of knowledge are people who have been trained and educated at CERN and also at other institutes: here is where the Global Network comes into play", says Rolf Heuer, CERN Director General. “During the first phase, the Network will be open to current and former members of the CERN personnel, that is, staff, fellows, apprentices, associates, students a...

  9. Plasma Therapy: An Overview

    Directory of Open Access Journals (Sweden)

    Rajkumar Diwan

    2011-01-01

    Full Text Available Definition: Plasma, the fourth state of matter, is a collection of charged particles (electrons, ions, neutral atoms. Recent demonstration of plasma technology in treatment of living cells, tissue and organs are creating a new field at the intersection of plasma science and technology with biology and medicine known as plasma medicine. Plasma medicine is one of the newest fields of modem applied plasma chemistry. It appeared several years ago and comprises studies concerning the direct action of low-temperature, one atmosphere air plasma (cold plasma/nonthermal plasmalnonequilibrium on body tissues for various noninvasive therapeutic treatments or diagnostics purpose. The study of plasma holds promise for a myriad of applications ranging from lasers and electronics, hazardous decontamination, sterilization and disinfection of foods, soil, water, instruments, to medical uses in wound healing and treating certain types of tumors and cancers. Plasma represents a new state-of-the-art sterilization and disinfection treatment for certain oral and environmental pathogens, heat-sensitive materials, hard and soft surfaces, and may assist health care facilities in the management of various health concerns. The role that low temperature atmospheric pressure plasma (LTAPP could play in the inactivation of pathogenic microorganisms might prove to be a new, faster, more economical alternative.

  10. Arc Plasma Torch Modeling

    CERN Document Server

    Trelles, J P; Vardelle, A; Heberlein, J V R

    2013-01-01

    Arc plasma torches are the primary components of various industrial thermal plasma processes involving plasma spraying, metal cutting and welding, thermal plasma CVD, metal melting and remelting, waste treatment and gas production. They are relatively simple devices whose operation implies intricate thermal, chemical, electrical, and fluid dynamics phenomena. Modeling may be used as a means to better understand the physical processes involved in their operation. This paper presents an overview of the main aspects involved in the modeling of DC arc plasma torches: the mathematical models including thermodynamic and chemical non-equilibrium models, turbulent and radiative transport, thermodynamic and transport property calculation, boundary conditions and arc reattachment models. It focuses on the conventional plasma torches used for plasma spraying that include a hot-cathode and a nozzle anode.

  11. Laminar Plasma Dynamos

    CERN Document Server

    Wang, Z; Barnes, C W; Barnes, D C; Wang, Zhehui; Pariev, Vladimir I.; Barnes, Cris W.; Barnes, Daniel C.

    2002-01-01

    A new kind of dynamo utilizing flowing laboratory plasmas has been identified. Conversion of plasma kinetic energy to magnetic energy is verified numerically by kinematic dynamo simulations for magnetic Reynolds numbers above 210. As opposed to intrinsically-turbulent liquid-sodium dynamos, the proposed plasma dynamos correspond to laminar flow topology. Modest plasma parameters, 1-20 eV temperatures, 10^{19}-10^{20} m^{-3} densities in 0.3-1.0 m scale-lengths driven by velocities on the order of the Alfven Critical Ionization Velocity (CIV), self-consistently satisfy the conditions needed for the magnetic field amplication. Growth rates for the plasma dynamos are obtained numerically with different geometry and magnetic Reynolds numbers. Magnetic-field-free coaxial plasma guns can be used to sustain the plasma flow and the dynamo.

  12. Plasma polymerization by Softplasma

    DEFF Research Database (Denmark)

    Jiang, J.; Wu, Zhenning; Benter, Maike

    2008-01-01

    In the late 19th century, the first depositions - known today as plasma polymers, were reported. In the last century, more and more research has been put into plasma polymers. Many different deposition systems have been developed. [1, 2] Shi F. F. broadly classified them into internal electrode......, external electrode, and electrodeless microwave or high frequency reactors. [3] Softplasma™ is an internal electrode plasma setup powered by low frequenc~ gower supply. It was developed in late 90s for surface treatment of silicone rubber. [ ]- 5] It is a low pressure, low electron density, 3D homogenous...... plasma. In this study, we are presenting the surface modification"pf polymers by plasma polymerization using Softplasma™. Softplasma™ can be used for two major types of polymerization: polymerization of vinyl monomers, where plasma acts as initiator; chemical vapour deposition, where plasma acts...

  13. Using Kappa Functions to Characterize Outer Heliosphere Proton Distributions in the Presence of Charge-exchange

    Science.gov (United States)

    Zirnstein, E. J.; McComas, D. J.

    2015-12-01

    Kappa functions have long been used in the analysis and modeling of suprathermal particles in various space plasmas. In situ observations of the supersonic solar wind show its distribution contains a cold ion core and power-law tail, which is well-represented by a kappa function. In situ plasma observations by Voyager, as well as observations of energetic neutral atom (ENA) spectra by the Interstellar Boundary Explorer (IBEX), showed that the compressed and heated inner heliosheath (IHS) plasma beyond the termination shock can also be represented by a kappa function. IBEX exposes the IHS plasma properties through the detection of ENAs generated by charge-exchange in the IHS. However, charge-exchange modifies the plasma as it flows through the IHS, and makes it difficult to ascertain the parent proton distribution. In this paper we investigate the evolution of proton distributions, initially represented by a kappa function, that experience losses due to charge-exchange in the IHS. In the absence of other processes, it is no longer representable by a single kappa function due to the energy-dependent, charge-exchange process. While one can still fit a kappa function to the evolving proton distribution over limited energy ranges, this yields fitting parameters (pseudo-density, pseudo-temperature, pseudo-kappa index) that depend on the energy range of the fit. We discuss the effects of fitting a kappa function to the IHS proton distribution over limited energy ranges, its dependence on the initial proton distribution properties at the termination shock, and implications for understanding the observations.

  14. USING KAPPA FUNCTIONS TO CHARACTERIZE OUTER HELIOSPHERE PROTON DISTRIBUTIONS IN THE PRESENCE OF CHARGE-EXCHANGE

    Energy Technology Data Exchange (ETDEWEB)

    Zirnstein, E. J.; McComas, D. J., E-mail: ezirnstein@swri.edu, E-mail: dmccomas@swri.edu [Southwest Research Institute, San Antonio, TX 78228 (United States)

    2015-12-10

    Kappa functions have long been used in the analysis and modeling of suprathermal particles in various space plasmas. In situ observations of the supersonic solar wind show its distribution contains a cold ion core and power-law tail, which is well-represented by a kappa function. In situ plasma observations by Voyager, as well as observations of energetic neutral atom (ENA) spectra by the Interstellar Boundary Explorer (IBEX), showed that the compressed and heated inner heliosheath (IHS) plasma beyond the termination shock can also be represented by a kappa function. IBEX exposes the IHS plasma properties through the detection of ENAs generated by charge-exchange in the IHS. However, charge-exchange modifies the plasma as it flows through the IHS, and makes it difficult to ascertain the parent proton distribution. In this paper we investigate the evolution of proton distributions, initially represented by a kappa function, that experience losses due to charge-exchange in the IHS. In the absence of other processes, it is no longer representable by a single kappa function due to the energy-dependent, charge-exchange process. While one can still fit a kappa function to the evolving proton distribution over limited energy ranges, this yields fitting parameters (pseudo-density, pseudo-temperature, pseudo-kappa index) that depend on the energy range of the fit. We discuss the effects of fitting a kappa function to the IHS proton distribution over limited energy ranges, its dependence on the initial proton distribution properties at the termination shock, and implications for understanding the observations.

  15. Plasmas for medicine

    Science.gov (United States)

    von Woedtke, Th.; Reuter, S.; Masur, K.; Weltmann, K.-D.

    2013-09-01

    Plasma medicine is an innovative and emerging field combining plasma physics, life science and clinical medicine. In a more general perspective, medical application of physical plasma can be subdivided into two principal approaches. (i) “Indirect” use of plasma-based or plasma-supplemented techniques to treat surfaces, materials or devices to realize specific qualities for subsequent special medical applications, and (ii) application of physical plasma on or in the human (or animal) body to realize therapeutic effects based on direct interaction of plasma with living tissue. The field of plasma applications for the treatment of medical materials or devices is intensively researched and partially well established for several years. However, plasma medicine in the sense of its actual definition as a new field of research focuses on the use of plasma technology in the treatment of living cells, tissues, and organs. Therefore, the aim of the new research field of plasma medicine is the exploitation of a much more differentiated interaction of specific plasma components with specific structural as well as functional elements or functionalities of living cells. This interaction can possibly lead either to stimulation or inhibition of cellular function and be finally used for therapeutic purposes. During recent years a broad spectrum of different plasma sources with various names dedicated for biomedical applications has been reported. So far, research activities were mainly focused on barrier discharges and plasma jets working at atmospheric pressure. Most efforts to realize plasma application directly on or in the human (or animal) body for medical purposes is concentrated on the broad field of dermatology including wound healing, but also includes cancer treatment, endoscopy, or dentistry. Despite the fact that the field of plasma medicine is very young and until now mostly in an empirical stage of development yet, there are first indicators of its enormous

  16. Nonlinear Plasma Wave in Magnetized Plasmas

    CERN Document Server

    Bulanov, Sergei V; Kando, Masaki; Koga, James K; Hosokai, Tomonao; Zhidkov, Alexei G; Kodama, Ryosuke

    2013-01-01

    Nonlinear axisymmetric cylindrical plasma oscillations in magnetized collisionless plasmas are a model for the electron fluid collapse on the axis behind an ultrashort relativisically intense laser pulse exciting a plasma wake wave. We present an analytical description of the strongly nonlinear oscillations showing that the magnetic field prevents closing of the cavity formed behind the laser pulse. This effect is demonstrated with 3D PIC simulations of the laser-plasma interaction. An analysis of the betatron oscillations of fast electrons in the presence of the magnetic field reveals a characteristic "Four-Ray Star" pattern which has been observed in the image of the electron bunch in experiments [T. Hosokai, et al., Phys. Rev. Lett. 97, 075004 (2006)].

  17. Colloquium: Nonlinear Collective Interactions in Dense Plasmas

    CERN Document Server

    Shukla, P K

    2010-01-01

    The current understanding of some important collective processes in dense quantum plasmas is presented. After reviewing the basic properties of dense quantum plasmas with degenerate electrons, we present model equations (e.g. the quantum hydrodynamic and effective nonlinear Schr\\"odinger-Poisson equations) that describe collective nonlinear phenomena at nanoscales. The effects of the electron degeneracy arise due to Heisenberg's uncertainty principle and Pauli's exclusion principle for overlapping electron wave functions that result in a nonlinear quantum electron pressure and tunneling/diffusion of electrons through a nonlinear quantum Bohm potential. Since degenerate electrons have $1/2-$spin due to their Fermionic nature, there also appear a spin electron current and a spin force acting on the electrons due to the Bohr magnetization. The present nonlinear equations do not include strong electron correlations and electron-exchange interactions. The quantum effects caused by the electron degeneracy produce n...

  18. Plasma confinement system and methods for use

    Energy Technology Data Exchange (ETDEWEB)

    Jarboe, Thomas R.; Sutherland, Derek

    2017-09-05

    A plasma confinement system is provided that includes a confinement chamber that includes one or more enclosures of respective helicity injectors. The one or more enclosures are coupled to ports at an outer radius of the confinement chamber. The system further includes one or more conductive coils aligned substantially parallel to the one or more enclosures and a further set of one or more conductive coils respectively surrounding portions of the one or more enclosures. Currents may be provided to the sets of conductive coils to energize a gas within the confinement chamber into a plasma. Further, a heat-exchange system is provided that includes an inner wall, an intermediate wall, an outer wall, and pipe sections configured to carry coolant through cavities formed by the walls.

  19. Sustainability of a public system for plasma collection, contract fractionation and plasma-derived medicinal product manufacturing.

    Science.gov (United States)

    Grazzini, Giuliano; Ceccarelli, Anna; Calteri, Deanna; Catalano, Liviana; Calizzani, Gabriele; Cicchetti, Americo

    2013-09-01

    In Italy, the financial reimbursement for labile blood components exchanged between Regions is regulated by national tariffs defined in 1991 and updated in 1993-2003. Over the last five years, the need for establishing standard costs of healthcare services has arisen critically. In this perspective, the present study is aimed at defining both the costs of production of blood components and the related prices, as well as the prices of plasma-derived medicinal products obtained by national plasma, to be used for interregional financial reimbursement. In order to analyse the costs of production of blood components, 12 out 318 blood establishments were selected in 8 Italian Regions. For each step of the production process, driving costs were identified and production costs were. To define the costs of plasma-derived medicinal products obtained by national plasma, industrial costs currently sustained by National Health Service for contract fractionation were taken into account. The production costs of plasma-derived medicinal products obtained from national plasma showed a huge variability among blood establishments, which was much lower after standardization. The new suggested plasma tariffs were quite similar to those currently in force. Comparing the overall costs theoretically sustained by the National Health Service for plasma-derived medicinal products obtained from national plasma to current commercial costs, demonstrates that the national blood system could gain a 10% cost saving if it were able to produce plasma for fractionation within the standard costs defined in this study. Achieving national self-sufficiency through the production of plasma-derived medicinal products from national plasma, is a strategic goal of the National Health Service which must comply not only with quality, safety and availability requirements but also with the increasingly pressing need for economic sustainability.

  20. Impact of Detoxification Techniques on Pulmonary Gas Exchange Function in Patients with Generalized Peritonitis

    Directory of Open Access Journals (Sweden)

    R. A. Mlinnik

    2012-01-01

    Full Text Available Objective: to analyze the impact of different detoxification techniques on pulmonary gas exchange function in patients with generalized peritonitis complicated by multiple organ failure. Subjects and methods. One hundred and thirty patients with generalized peritonitis were examined. According to the used detoxification techniques, the patients were divided into 5 groups. All the patients underwent a comprehensive examination, the key element of which was the evaluation of gas exchange parameters. Results. Membrane plasmapheresis and plasmapheresis with sodium hypochlorite infusion to the plasma filter in patients with peritonitis are shown to improve pulmonary blood oxygenation.

  1. Extraordinary waves in two dimensional electron gas with separate spin evolution and Coulomb exchange interaction

    CERN Document Server

    Andreev, Pavel A

    2016-01-01

    Hydrodynamics analysis of waves in two-dimensional degenerate electron gas with the account of separate spin evolution is presented. The transverse electric field is included along with the longitudinal electric field. The Coulomb exchange interaction is included in the analysis. In contrast with the three-dimensional plasma-like mediums the contribution of the transverse electric field is small. We show the decrease of frequency of both the extraordinary (Langmuir) wave and the spin-electron acoustic wave due to the exchange interaction. Moreover, spin-electron acoustic wave has negative dispersion at the relatively large spin-polarization. Corresponding dispersion dependencies are presented and analyzed.

  2. The Sodium and Potassium Exchange between Intact Frogs and Their Environment

    Science.gov (United States)

    STEINBACH, H. BURR

    1966-01-01

    Intact living frogs (Rana pipiens) were partially immersed in dilute salt solution labeled with K42 or Na24 or, alternatively, injected with Ringer’s fluid containing the appropriate isotope and then partially immersed in unlabeled dilute salt. Before isotopic equilibrium, the animals were sacrificed and specific activities of K42 and Na24 were determined for medium, skin, plasma, and other tissues. With Na24, entering from the medium or escaping to the medium, specific activities of the skin approach that of the plasma. For K42, entering from the medium, the specific activity exceeds that of the plasma. The results are interpreted as indicating that the exchange rate for Na is greater plasma to skin than medium to skin, with the reverse situation for K. Values are given for average Na, K, and Cl contents of the various organ systems. PMID:5924103

  3. SAFE gas turbine cycle primary heat exchangers

    Science.gov (United States)

    Reid, Robert S.; Kapernick, Richard J.

    2002-01-01

    Los Alamos National Laboratory and Marshall Space Flight Center are jointly developing two modular heat pipe heat exchangers, collectively named FIGMENT (Fission Inert Gas Metal Exchanger for Non-nuclear Testing). The FIGMENT heat exchangers are designed to transfer power from the SAFE nuclear reactor cores to gas turbine energy converters. A stainless steel prototype heat exchanger will be built during 2002 in preparation for the construction of a larger refractory metal version. Two promising FIGMENT stainless steel heat exchanger concepts are reviewed here. .

  4. Finned Small Diameter Tube Heat Exchanger

    Science.gov (United States)

    Dang, Chaobin; Daiguji, Hirofumi; Hihara, Eiji; Tokunaga, Masahide

    The performance of fined small tube heat exchangers was investigated both experimentally and theoretically. The Inner diameters of tubes were 1.0mm, 2.1mm and 4.0mm. Exchanged heat and pressure drop obtained from numerical simulation agreed well with the experimental ones. Calculation results show that the volume of a 2.0mm tube heat exchanger can be reduced to 33% of that of a 4mm tube heat exchanger with the same capacity. In addition the distribution of two-phase flow in a branching unit was investigated by measuring downstream temperature distribution. The flow distribution in a branching unit strongly affects the exchanged heat.

  5. Why PPP Real Exchange Rates Mislead

    OpenAIRE

    Larry A Sjaastad

    1998-01-01

    This paper investigates the properties of the purchasing-power-parity (PPP) real exchange rate as a proxy for the true real exchange rate, which is defined as the relative price of traded goods. It finds that the PPP real exchange rate is prone to measurement error and examines the nature of that error. Measurement error is defined as the fraction of the variance of the PPP real exchange rate that has no counterpart in the true real exchange rate. That measurement error is estimated for seven...

  6. MULTI-ITEM FAIR EXCHANGE SCHEME

    Institute of Scientific and Technical Information of China (English)

    Zheng Dong; Chen Kefei

    2002-01-01

    As more business is conduced over the Internet, the fair exchange problem assumes increasing importance. However, the problem of multi-party fair exchange has not been studied as widely as the more fundamental problem of 2-party fair exchange. Recently, Franklin and Tsudik proposed two protocols for n-party multi-item exchange on FC'98, SUCEX-1 and SUCES-2. This paper first gives an attack on the proposed protocol SUCEX-1, then presents two protocols for multi-item exchange, one is an improved protocol of SUCEX-1, another is the extension of protocol SUCEX-2.

  7. Optimal counter-current exchange networks

    CERN Document Server

    Farr, Robert S

    2016-01-01

    We construct a general analysis for exchange devices linking their efficiency to the (potentially fractal) geometry of the exchange surface and supply network. For certain parameter ranges, we show that the optimal exchanger consists of densely packed pipes which span a thin sheet of large area, which may be crumpled into a fractal surface and supplied with a fractal network of pipes. We present the efficiencies of such fractal exchangers, showing factor gains compared to regular exchangers, using parameters relevant for systems such as pigeon lungs and salmon gills.

  8. MULTI—ITEM FAIR EXCHANGE SCHEME

    Institute of Scientific and Technical Information of China (English)

    ZhengDong; ChenKefei

    2002-01-01

    As more ubsiness is conduced over the Internet,the fair exchange problem assumes increasing importance,However,the problem of multi-party fair exchange has not been studied as widely as the more fundamental problem of 2-party fair exchange,Recently,Franklin and Tsudik proposed two protocols for n-parth multi-item exchange on FC'98,SUCEX-1 and SUCES-2,This paper first gives an attack on the proposed protocol SUCEX-1,then presents two protocols for multi-item exchange,one is an improoved protocol of SUCEX-1,another is the extension of protocol SUCEX-2.

  9. Solid state exchange reactions and thermal decomposition

    Energy Technology Data Exchange (ETDEWEB)

    Albarran, G.; Archundia, C.; Maddock, A.G.

    1982-01-01

    A further study of exchange of the cobalt atoms in solid Co(H/sub 2/O)/sub 6/(Co EDTA)/sub 2/ x 4H/sub 2/O has been made. The exchange is more easily measured when the compound has been ..gamma.. irradiated before heating. Without irradiation the exchange is complicated by substantial concurrent thermal decomposition. Vacuum dehydration to the tetrahydrate can be effected at 366 K without appreciable exchange. A relation between exchange, annealing of radiolytic decomposition and thermal decomposition in such compounds is suggested.

  10. Exchange Rate Behavior and Exchange Rate Puzzles: Why the XVIII Century Might Help.

    OpenAIRE

    Torres-Sánchez, R. (Rafael); Gómez-Biscarri, J. (Javier); Pérez-de-Gracia, F. (Fernando)

    2005-01-01

    This article explores the behavior of exchange rates in Spain during the XVIII century. We posit that exchange rates were the result of both government intervention over nominal values of currencies and the estimate that the market of bills of exchange- gave to the value of the currency. We analyze the exchange rates quoted in London on three Spanish cities between 1699 and 1826. After a brief overview of the functioning of the Spanish monetary system and of exchange rate determination, we as...

  11. Does the Nominal Exchange Rate Regime Affect the Long Run Properties of Real Exchange Rates?

    OpenAIRE

    Dreger, Christian; Girardin, Eric

    2007-01-01

    This paper examines whether the behaviour of the real exchange rate is associated with a particular regime for the nominal exchange rate, like fixed and flexible exchange rate arrangements. The analysis is based on 16 annual real exchange rates and covers a long time span, 1870-2006. Four subperiods are distinguished and linked to exchange rate regimes: the Gold Standard, the interwar float, the Bretton Woods system and the managed float thereafter. Panel integration techniques are applied to...

  12. The determinants of exchange rate in Croatia

    Directory of Open Access Journals (Sweden)

    Manuel BENAZIC

    2016-06-01

    Full Text Available The dilemma for every country with an independent monetary policy is which kind of exchange rate arrangement should be applied. Through the exchange rate policy, countries can influence their economies, i.e. price stability and export competiveness. Croatia is a new EU member state, it has its own monetary policy and currency but it is on the way to euro introduction. Regarding the experiences from the beginning of the 1990s when Croatia was faced with serious monetary instabilities and hyperinflation, the goal of Croatian National Bank (CNB is to ensure price stability and one way to do so is through exchange rate policy. Croatia, as a small and open economy, has applied a managed floating exchange rate regime. The exchange rate is determined primarily by the foreign exchange supply and demand on the foreign exchange market, with occasional market interventions by the CNB. Therefore, in order to maintain exchange rate stability, policymakers must be able to recognize how changes in these factors affect changes in the exchange rate. This research aims to find a relationship among the main sources of foreign currency inflow and outflow and the level of exchange rate in Croatia. The analysis is carried out by using the bounds testing (ARDL approach for co-integration. The results indicate the existence of a stable co-integration relationship between the observed variables, whereby an increase in the majority of variables leads to an exchange rate appreciation.

  13. Foreign Exchange Exposure of Korean Firms

    Directory of Open Access Journals (Sweden)

    Ji-Seon Kim

    2002-12-01

    Full Text Available The purpose of this study is to examine the relationship between the movements of exchange rate and value of Korean firms, so-called foreign exchange rate exposure using newly devised model to find the strong evidence. I use weekly data on Korean Firms that are listed on Korea Stock Exchange (KSE for the period from January 1997 to December 2000. I find that about 70% Korean Firms are actually exposed to Won-dollar exchange rate movement at 10% significance level and these results are substantially different from the previous empirical study where little statistical significance was found. In comparing the foreign exchange exposures with three different exchange rates, in Won-dollar and Won-yen exchange exposures, value of Korean firms is positively related to depreciation of Korean Won and negatively related to depreciation of Korean Won with Won-euro exchange exposure. With magnitude of three exposures, results can be interpreted that Dollar exposure seems to be the most significant among three foreign exchange exposures and Korean Firms' value is more sensitive to Won-dollar exchange rate. I also find that exchange exposure is strongly related to firm size and industry especially Electricity & Gas industry is most significantly related.

  14. Space and Astrophysical Plasmas : Sun–Earth connection: Boundary layer waves and auroras

    Indian Academy of Sciences (India)

    G S Lakhina; B T Tsurutani; J K Arballo; C Galvan

    2000-11-01

    Boundary layers are the sites where energy and momentum are exchanged between two distinct plasmas. Boundary layers occurring in space plasmas can support a wide spectrum of plasma waves spanning a frequency range of a few mHz to 100 kHz and beyond. The main characteristics of the broadband plasma waves (with frequencies > 1 Hz) observed in the magnetopause, polar cap, and plasma sheet boundary layers are described. The rapid pitch angle scattering of energetic particles via cyclotron resonant interactions with the waves can provide sufficient precipitated energy flux to the ionosphere to create the diffused auroral oval. The broadband plasma waves may also play an important role in the processes of local heating/acceleration of the boundary layer plasma.

  15. Tear exchange and contact lenses: a review.

    Science.gov (United States)

    Muntz, Alex; Subbaraman, Lakshman N; Sorbara, Luigina; Jones, Lyndon

    2015-01-01

    Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses.

  16. A mechanism of raft formation on both plasma membrane layers

    Science.gov (United States)

    Sornbundit, Kan; Modchang, Charin; Triampo, Wannapong; Triampo, Darapond; Nuttavut, Narin

    2013-10-01

    A double-layered membrane model is proposed to explain raft formation and induction on extracellular (outer) and cytoplasmic (inner) leaflets of plasma membranes in a situation where only the outer layer has a tendency to phase-separate. In the model, lipid exchange with the surrounding medium is allowed on both layers, but lipid exchange between layers is not allowed. Simulations display domain stabilization on both layers. The effect of the lipid recycling frequencies on stationary domain sizes is also investigated. It is found that stationary domain sizes decrease when lipid recycling frequencies are stronger. Linear stability analysis is used to verify the results.

  17. A potential kidney-bone axis involved in the rapid minute-to-minute regulation of plasma Ca2+

    DEFF Research Database (Denmark)

    Nordholm, Anders; Mace, Maria L; Gravesen, Eva;

    2015-01-01

    of plasma-Ca(2+) (p-Ca(2+)) takes place via an exchange mechanism of Ca(2+) between plasma and bone. A labile Ca storage pool exists on bone surfaces storing excess or supplying Ca when blood Ca is lowered. Aim was to examine minute-to-minute regulation of p-Ca(2+) in the very early phase of acute uremia...

  18. Plasma Biomedicine in Orthopedics

    Science.gov (United States)

    Hamaguchi, Satsohi

    2012-10-01

    Various effects of plasmas irradiation on cells, tissues, and biomaterials relevant for orthopedic applications have been examined. For direct application of plasmas to living cells or tissues, dielectric barrier discharges (DBDs) with helium flows into ambient air were used. For biomaterial processing, on the other hand, either helium DBDs mentioned above or low-pressure discharges generated in a chamber were used. In this presentation, plasma effects on cell proliferation and plasma treatment for artificial bones will be discussed. First, the conditions for enhanced cell proliferation in vitro by plasma applications have been examined. The discharge conditions for cell proliferation depend sensitively on cell types. Since cell proliferation can be enhanced even when the cells are cultured in a plasma pre-treated medium, long-life reactive species generated in the medium by plasma application or large molecules (such as proteins) in the medium modified by the plasma are likely to be the cause of cell proliferation. It has been found that there is strong correlation between (organic) hydroperoxide generation and cell proliferation. Second, effects of plasma-treated artificial bones made of porous hydroxyapatite (HA) have been examined in vitro and vivo. It has been found that plasma treatment increases hydrophilicity of the surfaces of microscopic inner pores, which directly or indirectly promotes differentiation of mesenchymal stem cells introduced into the pores and therefore causes faster bone growth. The work has been performed in collaboration with Prof. H. Yoshikawa and his group members at the School of Medicine, Osaka University.

  19. Plasma detachment in linear devices

    Science.gov (United States)

    Ohno, N.

    2017-03-01

    Plasma detachment research in linear devices, sometimes called divertor plasma simulators, is reviewed. Pioneering works exploring the concept of plasma detachment were conducted in linear devices. Linear devices have contributed greatly to the basic understanding of plasma detachment such as volume plasma recombination processes, detached plasma structure associated with particle and energy transport, and other related issues including enhancement of convective plasma transport, dynamic response of plasma detachment, plasma flow reversal, and magnetic field effect. The importance of plasma detachment research using linear devices will be highlighted aimed at the design of future DEMO.

  20. Analysis of pedestal plasma transport

    Energy Technology Data Exchange (ETDEWEB)

    Callen, J. D. [University of Wisconsin, Madison; Groebner, R. [General Atomics, San Diego; Osborne, T.H. [General Atomics, San Diego; Canik, John [ORNL; Owen, Larry W [ORNL; Pankin, A. Y. [Lehigh University, Bethlehem, PA; Rafiq, T. [Lehigh University, Bethlehem, PA; Rognlien, T. D. [Lawrence Livermore National Laboratory (LLNL); Stacey, W. M. [Georgia Institute of Technology

    2010-01-01

    An H-mode edge pedestal plasma transport benchmarking exercise was undertaken for a single DIII-D pedestal. Transport modelling codes used include 1.5D interpretive (ONETWO, GTEDGE), 1.5D predictive (ASTRA) and 2D ones (SOLPS, UEDGE). The particular DIII-D discharge considered is 98889, which has a typical low density pedestal. Profiles for the edge plasma are obtained from Thomson and charge-exchange recombination data averaged over the last 20% of the average 33.53 ms repetition time between type I edge localized modes. The modelled density of recycled neutrals is largest in the divertor X-point region and causes the edge plasma source rate to vary by a factor similar to 10(2) on the separatrix. Modelled poloidal variations in the densities and temperatures on flux surfaces are small on all flux surfaces up to within about 2.6 mm (rho(N) > 0.99) of the mid-plane separatrix. For the assumed Fick's-diffusion-type laws, the radial heat and density fluxes vary poloidally by factors of 2-3 in the pedestal region; they are largest on the outboard mid-plane where flux surfaces are compressed and local radial gradients are largest. Convective heat flows are found to be small fractions of the electron (less than or similar to 10%) and ion (less than or similar to 25%) heat flows in this pedestal. Appropriately averaging the transport fluxes yields interpretive 1.5D effective diffusivities that are smallest near the mid-point of the pedestal. Their 'transport barrier' minima are about 0.3 (electron heat), 0.15 (ion heat) and 0.035 (density) m(2) s(-1). Electron heat transport is found to be best characterized by electron-temperature-gradient-induced transport at the pedestal top and paleoclassical transport throughout the pedestal. The effective ion heat diffusivity in the pedestal has a different profile from the neoclassical prediction and may be smaller than it. The very small effective density diffusivity may be the result of an inward pinch flow nearly