WorldWideScience

Sample records for plasma diagnostics

  1. Diagnostics of Nanodusty Plasma

    Science.gov (United States)

    Greiner, Franko; Groth, Sebastian; Tadsen, Bejamin; Piel, Alexander

    2015-11-01

    The diagnostic of nanodusty plasmas, i.e. plasmas including nano-sized dust particles, is a challenging task. For both, the diagnostic of the nanodusty plasma itself, and the in-situ diagnostic of the nanoparticles, no standard diagnostic exist. Nanodust particle size and density can be estimated using light scattering techniques, namely kinetic Mie ellipsometry and extinction measurements. The charge of the nanoparticles can be estimated from the analysis of dust density waves (DDW). Parameters like the electron density, which give information about the plasma itself, may be deduced from the DDW analysis. We present detailed investigations on nanodust in a reactive Argon-Acetylene plasma created in an rf-driven parallel plate reactor at low pressure using the above mentioned portfolio of diagnostic. Funded by DFG under contract SFB TR-24/A2.

  2. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  3. Plasma diagnostics for tokamaks and stellarators

    Energy Technology Data Exchange (ETDEWEB)

    Stott, P. E.; Sanchez, J.

    1994-07-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: Magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Scattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma. (Author) 451 refs.

  4. Far infrared fusion plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Luhmann, N.C. Jr.; Peebles, W.A.

    1990-01-01

    Over the last several years, reflectometry has grown in importance as a diagnostic for both steady-state density Profiles as well as for the investigation of density fluctuations and turbulence. As a diagnostic for density profile measurement, it is generally believed to be well understood in the tokamak environment. However, its use as a fluctuation diagnostic is hampered by a lack of quantitative experimental understanding of its wavenumber sensitivity and spatial resolution. Several researchers, have theoretically investigated these questions. However, prior to the UCLA laboratory investigation, no group has experimentally investigated these questions. Because of the reflectometer's importance to the world effort in understanding plasma turbulence and transport, UCLA has, over the last year, made its primary Task IIIA effort the resolution of these questions. UCLA has taken the lead in a quantitative experimental understanding of reflectometer data as applied to the measurement of density fluctuations. In addition to this, work has proceeded on the design, construction, and installation of a reflectometer system on UCLA's CCT tokamak. This effort will allow a comparison between the improved confinement regimes (H-mode) observed on both the DIII-D and CCT machines with the goal of achieving a physics understanding of the phenomena. Preliminary investigation of a new diagnostic technique to measure density profiles as a function of time has been initiated at UCLA. The technique promises to be a valuable addition to the range of available plasma diagnostics. Work on advanced holographic reflectometry technique as applied to fluctuation diagnostics has awaited a better understanding of the reflectometer signal itself as discussed above. Efforts to ensure the transfer of the diagnostic developments have continued with particular attention devoted to the preliminary design of a multichannel FIR interferometer for MST.

  5. Advanced plasma diagnostics for plasma processing

    Science.gov (United States)

    Malyshev, Mikhail Victorovich

    1999-10-01

    A new, non-intrusive, non-perturbing diagnostic method was developed that can be broadly applied to low pressure, weakly ionized plasmas and glow discharges-trace rare gases optical emission spectroscopy (TRG-OES). The method is based on a comparison of intensities of atomic emission from trace amounts of inert gases (He, Ne, Ar, Kr, and Xe) that are added to the discharge to intensities calculated from the theoretical model. The model assumes a Maxwellian electron energy distribution function (EEDF), computes the population of emitting levels both from the ground state and the metastable states of rare gases, and from the best fit between theory and experiment determines electron temperature (Te). Subject to conditions, TRG-OES can also yield electron density or its upper or lower limit. From the comparison of the emission from levels excited predominantly by high energy electrons to that excited by low energy electrons, information about the EEDF can be obtained. The use of TRG-OES also allows a traditionally qualitative actinometry technique (determination of concentration of radical species in plasma through optical emission) to become a precise quantitative method by including Te and rare gases metastables effects. A combination of TRG-OES, advanced actinometry, and Langmuir probe measurements was applied to several different plasma reactors and regimes of operation. Te measurements and experiments to correct excitation cross section were conducted in a laboratory helical resonator. Two chamber configuration of a commercial (Lam Research) metal etcher were studied to determine the effects of plasma parameters on plasma-induced damage. Two different methods (RF inductive coupling and ultra-high frequency coupling) for generating a plasma in a prototype reactor were also studied. Pulsed plasmas, a potential candidate to eliminate the plasma-induced damage to microelectronics devices that occurs in manufacturing due to differential charging of the wafer, have

  6. Microwave diagnostics of atmospheric plasmas

    Science.gov (United States)

    Scott, David

    Plasma treatment of biological tissues has tremendous potential due to the wide range of applications. Most plasmas have gas temperatures which greatly exceed room temperature. These are often utilized in electro-surgery for cutting and coagulating tissue. Another type of plasma, referred to as cold atmospheric plasma, or CAP, is characterized by heavy particle temperatures which are at or near room temperature. Due to this lack of thermal effect, CAP may provide less invasive medical procedures. Additionally, CAP have been demonstrated to be effective at targeting cancer cells while minimizing damage to the surrounding tissue. A recently fabricated Microwave Electron Density Device (MEDD) utilizes microwave scattering on small atmospheric plasmas to determine the electron plasma density. The MEDD can be utilized on plasmas which range from a fraction of a millimeter to several centimeters at atmospheric pressure when traditional methods cannot be applied. Microwave interferometry fails due to the small size of the plasma relative to the microwave wavelength which leads to diffraction and negligible phase change; electrostatic probes introduce very strong perturbation and are associated with difficulties of application in strongly-collisional atmospheric conditions; and laser Thomson scattering is not sensitive enough to measure plasma densities less than 1012 cm-3. The first part of this dissertation provides an overview of two types of small atmospheric plasma objects namely CAPs and plasmas utilized in the electro-surgery. It then goes on to describe the fabrication, testing and calibration of the MEDD facility. The second part of this dissertation is focused on the application of the MEDD and other diagnostic techniques to both plasma objects. A series of plasma images that illustrate the temporal evolution of a discharge created by an argon electrosurgical device operating in the coagulation mode and its behavior was analyzed. The discharge of the argon

  7. Optical diagnostics of femtosecond laser plasmas

    Institute of Scientific and Technical Information of China (English)

    李玉同; 张杰; 陈黎明; 夏江帆; 腾浩; 赵理曾; 林景全; 李英骏; 魏志义; 王龙; 江文勉

    2001-01-01

    Optical diagnostics of evolution of plasmas produced by ultrashort laser pulses is carried out using a femtosecond probing beam. The time sequence of plasma shadowgrams and interferograms are obtained. The filamentation instability in high_density region induces the local density modification. Large_scale toroidal magnetic fields confine plasma expansion in the transverse direction, resulting in the formation of a plasma jet. The plasma expansion along the target normal direction is found to scale as 1 2.

  8. Plasma diagnostics in plasma processing for nanotechnology and nanolevel chemistry

    Directory of Open Access Journals (Sweden)

    Hiroshi Akatsuka

    2004-01-01

    Full Text Available The author reviews the role of various plasma diagnostics in plasma processing for nanotechnology, and points out some essential methods of spectroscopic methods to diagnose plasmas for nanoprocessing. Two experimental examples are discussed between the characteristics of nanomaterials and plasma parameters. One is measurement of rotation temperature in processing of carbon nanotube. The other is that of vibrational temperature in surface nitriding of titanium by nitrogen plasma processing. We summarize what to measure and how to measure them from the technical viewpoint of plasma diagnostics.

  9. ISTTOK plasma control with the tomography diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, H.; Caralho, P.J.; Duarte, P.; Pereira, T.; Coelho, R.; Silva, C. [Association Euratom/IST, Institute of Plasmas and Nuclear Fusion, Technology Graduate Institute, P-1049-001 Lisbon (Portugal)

    2011-07-01

    A real-time plasma position control system is mandatory to achieve long duration (up to 250 ms), Alternating Current (AC) discharges on the ISTTOK tokamak. Such a system has been used for some time supported only on magnetic field diagnostic data. However, this system does not function accurately when the plasma current is low, rendering it inoperative during the plasma current reversal. A tomography diagnostic with 3 pinhole cameras and 8 silicone photodiode channels per camera was installed and customized to supply alternative plasma position to be used for plasma position control. As no filtering is applied, most of the radiation detected is in the visible/near-UV range. This system (i) executes a tomographic reconstruction, (ii) determines the average emissivity position from it, (iii) calculates the shift from the required position and (iv) supplies the vertical field power supply unit with the desired current value, all in less than 100 {mu}s. The horizontal magnetic field power supply unit is expected to be included in the system and will have no impact in the process time. This paper presents the tomography diagnostic architecture together with results of its scientific exploitation in ISTTOK AC discharges, where it has proven to be capable of supplying an accurate plasma position during the current reversal. The use of the tomography diagnostic for plasma position overcomes some limitations of the magnetic diagnostics, but poses challenges of its own such as blindness to plasma current direction. (authors)

  10. Some plasma aspects and plasma diagnostics of ion sources.

    Science.gov (United States)

    Wiesemann, Klaus

    2008-02-01

    We consider plasma properties in the most advanced type of plasma ion sources, electron cyclotron resonance ion sources for highly charged ions. Depending on the operation conditions the plasma in these sources may be highly ionized, which completely changes its transport properties. The most striking difference to weakly ionized plasma is that diffusion will become intrinsically ambipolar. We further discuss means of plasma diagnostics. As noninvasive diagnostic methods we will discuss analysis of the ion beam, optical spectroscopy, and measurement of the x-ray bremsstrahlung continuum. From beam analysis and optical spectroscopy one may deduce ion densities, and electron densities and distribution functions as a mean over the line of sight along the axis (optical spectroscopy) or at the plasma edge (ion beam). From x-ray spectra one obtains information about the population of highly energetic electrons and the energy transfer from the driving electromagnetic waves to the plasma -- basic data for plasma modeling.

  11. Diagnostics of laser ablated plasma plumes

    DEFF Research Database (Denmark)

    Amoruso, S.; Toftmann, B.; Schou, Jørgen;

    2004-01-01

    The effect of an ambient gas on the expansion dynamics of laser ablated plasmas has been studied for two systems by exploiting different diagnostic techniques. First, the dynamics of a MgB2 laser produced plasma plume in an Ar atmosphere has been investigated by space-and time-resolved optical...

  12. Plasma diagnostics surface analysis and interactions

    CERN Document Server

    Auciello, Orlando

    2013-01-01

    Plasmas and their interaction with materials have become subjects of major interest because of their importance in modern forefront technologies such as microelectronics, fusion energy, and space. Plasmas are used in microelectronics to process semiconductors (etching of patterns for microcircuits, plasma-induced deposition of thin films, etc.); plasmas produce deleterious erosion effects on surfaces of materials used for fusion devices and spaceships exposed to the low earth environment.Diagnostics of plasmas and materials exposed to them are fundamental to the understanding of the physical a

  13. Microwave Diagnostics of Ultracold Neutral Plasma

    CERN Document Server

    Guo, Ronghua Lu Li

    2010-01-01

    We suggest an approach for using microwave radiation in diagnostics of ultracold neutral plasma. Microwave scattering from ultracold neutral plasma is calculated . Simple formulations are get and indicate that the dipole radiation power of ultracold neutral plasma does not depend on density profile $n_e(r)$ and $\\omega$ when $\\omega\\gg\\omega_{pe0}$, but on the total electron number $N_e$. This method provides the information of $N_e$ and from which we can get the three body recombination rate of the plasma, which is extremely important in the researches of ultracold neutral plasma.

  14. Synthetic diagnostics platform for fusion plasmas (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Shi, L., E-mail: lshi@pppl.gov; Valeo, E. J.; Tobias, B. J.; Kramer, G. J.; Hausammann, L.; Tang, W. M. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540 (United States); Chen, M. [Department of Mechanical and Aerospace Engineering, University of California, Davis, California 95616 (United States)

    2016-11-15

    A Synthetic Diagnostics Platform (SDP) for fusion plasmas has been developed which provides state of the art synthetic reflectometry, beam emission spectroscopy, and Electron Cyclotron Emission (ECE) diagnostics. Interfaces to the plasma simulation codes GTC, XGC-1, GTS, and M3D-C{sup 1} are provided, enabling detailed validation of these codes. In this paper, we give an overview of SDP’s capabilities, and introduce the synthetic diagnostic modules. A recently developed synthetic ECE Imaging module which self-consistently includes refraction, diffraction, emission, and absorption effects is discussed in detail. Its capabilities are demonstrated on two model plasmas. The importance of synthetic diagnostics in validation is shown by applying the SDP to M3D-C{sup 1} output and comparing it with measurements from an edge harmonic oscillation mode on DIII-D.

  15. Diagnostics of nonlocal plasmas: advanced techniques

    Science.gov (United States)

    Mustafaev, Alexander; Grabovskiy, Artiom; Strakhova, Anastasiya; Soukhomlinov, Vladimir

    2014-10-01

    This talk generalizes our recent results, obtained in different directions of plasma diagnostics. First-method of flat single-sided probe, based on expansion of the electron velocity distribution function (EVDF) in series of Legendre polynomials. It will be demonstrated, that flat probe, oriented under different angles with respect to the discharge axis, allow to determine full EVDF in nonlocal plasmas. It is also shown, that cylindrical probe is unable to determine full EVDF. We propose the solution of this problem by combined using the kinetic Boltzmann equation and experimental probe data. Second-magnetic diagnostics. This method is implemented in knudsen diode with surface ionization of atoms (KDSI) and based on measurements of the magnetic characteristics of the KDSI in presence of transverse magnetic field. Using magnetic diagnostics we can investigate the wide range of plasma processes: from scattering cross-sections of electrons to plasma-surface interactions. Third-noncontact diagnostics method for direct measurements of EVDF in remote plasma objects by combination of the flat single-sided probe technique and magnetic polarization Hanley method.

  16. Online plasma diagnostics of a laser-produced plasma

    Science.gov (United States)

    Kai, Gao; Nasr, A. M. Hafz; Song, Li; Mohammad, Mirzaie; Guangyu, Li; Quratul, Ain

    2017-01-01

    In this study, we report a laser interferometry experiment for the online-diagnosing of a laser-produced plasma. The laser pulses generating the plasma are ultra-fast (30 femtoseconds), ultra-intense (tens of Terawatt) and are focused on a helium gas jet to generate relativistic electron beams via the laser wakefield acceleration (LWFA) mechanism. A probe laser beam (λ = 800 nm) which is split-off the main beam is used to cross the plasma at the time of arrival of the main pulse, allowing online plasma density diagnostics. The interferometer setup is based on the NoMarski method in which we used a Fresnel bi-prism where the probe beam interferes with itself after crossing the plasma medium. A high-dynamic range CCD camera is used to record the interference patterns. Based upon the Abel inversion technique, we obtained a 3D density distribution of the plasma density.

  17. Plasma Diagnostics by Antenna Impedance Measurements

    Science.gov (United States)

    Swenson, C. M.; Baker, K. D.; Pound, E.; Jensen, M. D.

    1993-01-01

    The impedance of an electrically short antenna immersed in a plasma provides an excellent in situ diagnostic tool for electron density and other plasma parameters. By electrically short we mean that the wavelength of the free-space electromagnetic wave that would be excited at the driving frequency is much longer than the physical size of the antenna. Probes using this impedance technique have had a long history with sounding rockets and satellites, stretching back to the early 1960s. This active technique could provide information on composition and temperature of plasmas for comet or planetary missions. Advantages of the impedance probe technique are discussed and two classes of instruments built and flown by SDL-USU for determining electron density (the capacitance and plasma frequency probes) are described.

  18. Diagnostics for the plasma liner experiment.

    Science.gov (United States)

    Lynn, A G; Merritt, E; Gilmore, M; Hsu, S C; Witherspoon, F D; Cassibry, J T

    2010-10-01

    The goal of the Plasma Liner Experiment (PLX) is to explore and demonstrate the feasibility of forming imploding spherical "plasma liners" via merging high Mach number plasma jets to reach peak liner pressures of ∼0.1 Mbar using ∼1.5 MJ of initial stored energy. Such a system would provide HED plasmas for a variety of fundamental HEDLP, laboratory astrophysics, and materials science studies, as well as a platform for experimental validation of rad-hydro and rad-MHD simulations. It could also prove attractive as a potential standoff driver for magnetoinertial fusion. Predicted parameters from jet formation to liner stagnation cover a large range of plasma density and temperature, varying from n(i)∼10(16) cm(-3), T(e)≈T(i)∼1 eV at the plasma gun mouth to n(i)>10(19) cm(-3), T(e)≈T(i)∼0.5 keV at stagnation. This presents a challenging problem for the plasma diagnostics suite which will be discussed.

  19. Plasma Diagnostics and Plasma-Surface Interactions in Inductively Coupled Plasmas

    OpenAIRE

    Titus, Monica Joy

    2010-01-01

    The semiconductor industry's continued trend of manufacturing device features on the nanometer scale requires increased plasma processing control and improved understanding of plasma characteristics and plasma-surface interactions. This dissertation presents a series of experimental results for focus studies conducted in an inductively coupled plasma (ICP) system. First novel "on-wafer" diagnostic tools are characterized and related to plasma characteristics. Second, plasma-polymer interactio...

  20. Adaptive Embedded Digital System for Plasma Diagnostics

    Science.gov (United States)

    González, Angel; Rodríguez, Othoniel; Mangual, Osvaldo; Ponce, Eduardo; Vélez, Xavier

    2014-05-01

    An Adaptive Embedded Digital System to perform plasma diagnostics using electrostatic probes was developed at the Plasma Engineering Laboratory at Polytechnic University of Puerto Rico. The system will replace the existing instrumentation at the Laboratory, using reconfigurable hardware to minimize the equipment and software needed to perform diagnostics. The adaptability of the design resides on the possibility of replacing the computational algorithm on the fly, allowing to use the same hardware for different probes. The system was prototyped using Very High Speed Integrated Circuits Hardware Description Language (VHDL) into an Field Programmable Gate Array (FPGA) board. The design of the Embedded Digital System includes a Zero Phase Digital Filter, a Derivative Unit, and a Computational Unit designed using the VHDL-2008 Support Library. The prototype is able to compute the Plasma Electron Temperature and Density from a Single Langmuir probe. The system was tested using real data previously acquired from a single Langmuir probe. The plasma parameters obtained from the embedded system were compared with results computed using matlab yielding excellent matching. The new embedded system operates on 4096 samples versus 500 on the previous system, and completes its computations in 26 milliseconds compared with about 15 seconds on the previous system.

  1. Comparative analyses of plasma probe diagnostics techniques

    Energy Technology Data Exchange (ETDEWEB)

    Godyak, V. A. [Electrical Engineering and Computer Science Department, University of Michigan, Ann Arbor, Michigan 48109, USA and RF Plasma Consulting, Brookline, Massachusetts 02446 (United States); Alexandrovich, B. M. [Plasma Sensors, Brookline, Massachusetts 02446 (United States)

    2015-12-21

    The subject of this paper is a comparative analysis of the plasma parameters inferred from the classical Langmuir probe procedure, from different theories of the ion current to the probe, and from measured electron energy distribution function (EEDF) obtained by double differentiation of the probe characteristic. We concluded that the plasma parameters inferred from the classical Langmuir procedure can be subjected to significant inaccuracy due to the non-Maxwellian EEDF, uncertainty of locating the plasma potential, and the arbitrariness of the ion current approximation. The plasma densities derived from the ion part of the probe characteristics diverge by as much as an order of magnitude from the density calculated according to Langmuir procedure or calculated as corresponding integral of the measured EEDF. The electron temperature extracted from the ion part is always subjected to uncertainty. Such inaccuracy is attributed to modification of the EEDF for fast electrons due to inelastic electron collisions, and to deficiencies in the existing ion current theories; i.e., unrealistic assumptions about Maxwellian EEDFs, underestimation of the ion collisions and the ion ambipolar drift, and discounting deformation of the one-dimensional structure of the region perturbed by the probe. We concluded that EEDF measurement is the single reliable probe diagnostics for the basic research and industrial applications of highly non-equilibrium gas discharge plasmas. Examples of EEDF measurements point up importance of examining the probe current derivatives in real time and reiterate significance of the equipment technical characteristics, such as high energy resolution and wide dynamic range.

  2. Charge Diagnostics for Laser Plasma Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, K.; Gonsalves, A. J.; Lin, C.; Sokollik, T.; Smith, A.; Rodgers, D.; Donahue, R.; Bryne, W.; Leemans, W. P.

    2010-06-01

    The electron energy dependence of a scintillating screen (Lanex Fast) was studied with sub-nanosecond electron beams ranging from 106 MeV to 1522 MeV at the Lawrence Berkeley National Laboratory Advanced Light Source (ALS) synchrotron booster accelerator. The sensitivity of the Lanex Fast decreased by 1percent per 100 MeV increase of the energy. The linear response of the screen against the charge was verified with charge density and intensity up to 160 pC/mm2 and 0.4 pC/ps/mm2, respectively. For electron beams from the laser plasma accelerator, a comprehensive study of charge diagnostics has been performed using a Lanex screen, an integrating current transformer, and an activation based measurement. The charge measured by each diagnostic was found to be within +/-10 percent.

  3. Diagnostic for the plasma liner experiment

    Energy Technology Data Exchange (ETDEWEB)

    Gilmore, M.; Merritt, E.; Lynn, A.G. [University of New Mexico, Albuquerque NM (United States); Bauer, B.S.; Fuelling, S.; Siemen, R.E. [University of Nevada, Reno NV (United States); Hsu, S.C. [Los Alamos National Laboratory, Los Alamos NM (United States); Witherspoon, F.D.; Brockington, S.; Case, A.; Messer, S.J. [HyperV Tecnologies Corp, Chantilly VA (United States); Cassibry, J.T. [University of Alabama, Huntsville AL (United States)

    2011-07-01

    Magneto-Inertial Fusion (MIF) includes a class of fusion energy concepts that seek to relax the required implosion times of inertial fusion to microseconds rather than nanoseconds by utilizing magnetized targets. The Plasma Liner Experiment (PLX) at Los Alamos National Laboratory will explore and demonstrate the feasibility of forming imploding spherical 'plasma liners' that can reach peak pressures {approx} 0.1 Mbar upon stagnation. The liners will be formed via merging of 30 - 60 dense, high Mach number plasma jets (M {approx} 10-35, v {approx} 50-70 km/s, jet radius {approx} 5 cm) in spherically convergent geometry. This is a staged, exploratory project where scientific issues will be studied first at modest stored energies ({approx} 300 kJ) before attempting to reach MIF-relevant pressures (requiring {approx} 1.5 MJ). Key physics issues include peak parameters (n, T, radius) at stagnation, dynamics of the merging jet liner formation (e.g. lateral shocks, instabilities), and spherical symmetry of the liner. Plasmas will be high-Z species (e.g. Ar, Xe), unmagnetized, and are expected to have densities {approx} 10{sup 22} m{sup -3} and low temperature, Te {approx} Ti {approx} a few eV, when initially exiting the plasma guns where the jets are formed. Density and temperature will first decrease slightly, then increase to n {approx} 10{sup 25} - 10{sup 26} m{sup -3} and Te {approx} Ti {approx} 100 eV as stagnation is approached over a 1 meter radial distance. The large range of densities (4-5 orders of magnitude), initially cold plasma, and short optical depth as the jets merge make diagnosing the plasma a particularly challenging problem. Initial diagnostics will include multi-chord visible interferometry and polarimetry, Schlieren imaging, visible and V-UV spectroscopy, fast 1-dimensional imaging diode arrays, fast visible cameras, bolometry, magnetic and electrostatic probes, and pressure sensitive 'witness plates' to measure pressure and jet

  4. Compact collimated fiber optic array diagnostic for railgun plasma experiments

    Energy Technology Data Exchange (ETDEWEB)

    Tang, V; Solberg, J; Ferriera, T; Tully, L; Stephan, P

    2008-10-02

    We have developed and tested a compact collimated sixteen channel fiber optic array diagnostic for studying the light emission of railgun armature plasmas with {approx}mm spatial and sub-{micro}s temporal resolution. The design and operational details of the diagnostic are described. Plasma velocities, oscillation, and dimension data from the diagnostic for the Livermore Fixed Hybrid Armature experiment are presented and compared with 1-D simulations. The techniques and principles discussed allow the extension of the diagnostic to other railgun and related dense plasma experiments.

  5. Compact collimated fiber optic array diagnostic for railgun plasmas.

    Science.gov (United States)

    Tang, V; Solberg, J M; Ferriera, T J; Tully, L K; Stephan, P L

    2009-01-01

    We developed and tested a compact collimated 16 channel fiber optic array diagnostic for studying the light emission of railgun armature plasmas with approximately millimeter spatial and submicrosecond temporal resolution. The design and operational details of the diagnostic are described. Plasma velocities, oscillation, and dimension data from the diagnostic for the Livermore fixed hybrid armature experiment are presented and compared with one-dimensional simulations. The techniques and principles discussed allow the extension of the diagnostic to other railgun and related dense plasma experiments.

  6. Passive Spectroscopic Diagnostics for Magnetically-confined Fusion Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, B. C.; Biter, M.; Hill, K. W.; Hillis, D. L.; Hogan, J. T.

    2007-07-18

    Spectroscopy of radiation emitted by impurities and hydrogen isotopes plays an important role in the study of magnetically-confined fusion plasmas, both in determining the effects of impurities on plasma behavior and in measurements of plasma parameters such as electron and ion temperatures and densities, particle transport, and particle influx rates. This paper reviews spectroscopic diagnostics of plasma radiation that are excited by collisional processes in the plasma, which are termed 'passive' spectroscopic diagnostics to distinguish them from 'active' spectroscopic diagnostics involving injected particle and laser beams. A brief overview of the ionization balance in hot plasmas and the relevant line and continuum radiation excitation mechanisms is given. Instrumentation in the soft X-ray, vacuum ultraviolet, ultraviolet, visible, and near-infrared regions of the spectrum is described and examples of measurements are given. Paths for further development of these measurements and issues for their implementation in a burning plasma environment are discussed.

  7. Second topical conference on high-temperature plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Jahoda, F.C.; Freese, K.B. (comps.)

    1978-02-01

    This report contains the program and abstracts of papers presented at the Second American Physical Society Topical Conference on High Temperature Plasma Diagnostics, March 1-3, 1978, Santa Fe, New Mexico.

  8. Advancements of microwave diagnostics in magnetically confined plasmas

    NARCIS (Netherlands)

    Mase, A.; Kogi, Y.; Ito, N.; Yokota, Y.; Akaki, K.; Kawahata, K.; Nagayama, Y.; Tokuzawa, T.; Yamaguchi, S.; Hojo, H.; Oyama, N.; N C Luhmann Jr.,; Park, H. K.; Donne, A. J. H.

    2009-01-01

    Microwave to millimeter-wave diagnostic techniques such as interferometry, reflectometry, scattering and radiometry have been powerful tools for diagnosing magnetically confined plasmas. Recent advances in electronic devices and components together with computer technology have enabled the developme

  9. Recent Advancements in Microwave Imaging Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    H. Park; C.C. Chang; B.H. Deng; C.W. Domier; A.J.H. Donni; K. Kawahata; C. Liang; X.P. Liang; H.J. Lu; N.C. Luhmann, Jr.; A. Mase; H. Matsuura; E. Mazzucato; A. Miura; K. Mizuno; T. Munsat; K. and Y. Nagayama; M.J. van de Pol; J. Wang; Z.G. Xia; W-K. Zhang

    2002-03-26

    Significant advances in microwave and millimeter wave technology over the past decade have enabled the development of a new generation of imaging diagnostics for current and envisioned magnetic fusion devices. Prominent among these are revolutionary microwave electron cyclotron emission imaging (ECEI), microwave phase imaging interferometers, imaging microwave scattering and microwave imaging reflectometer (MIR) systems for imaging electron temperature and electron density fluctuations (both turbulent and coherent) and profiles (including transport barriers) on toroidal devices such as tokamaks, spherical tori, and stellarators. The diagnostic technology is reviewed, and typical diagnostic systems are analyzed. Representative experimental results obtained with these novel diagnostic systems are also presented.

  10. Advanced Laser and RF Plasma Sources and Diagnostics

    Science.gov (United States)

    2007-06-13

    jacks, fibers, collimators, and breadboards $19,832.71 Interferometry Gunn diode and I-Q mixer $6,775.00 RF Components and Automation High...temperature diagnostics for both our laser window and radiofrequency air plasmas. We have also acquired a tunable 668 nm diode laser, optical filters...diagnostics for both our laser window and radiofrequency air plasmas. We have also acquired a tunable 668 nm diode laser, optical filters, splitters

  11. Plasma diagnostics and plasma-surface interactions in inductively coupled plasmas

    Science.gov (United States)

    Titus, Monica Joy

    The semiconductor industry's continued trend of manufacturing device features on the nanometer scale requires increased plasma processing control and improved understanding of plasma characteristics and plasma-surface interactions. This dissertation presents a series of experimental results for focus studies conducted in an inductively coupled plasma (ICP) system. First novel "on-wafer" diagnostic tools are characterized and related to plasma characteristics. Second, plasma-polymer interactions are characterized as a function of plasma species and processing parameters. Complementary simulations accompany each focus study to supplement experimental findings. Wafer heating mechanisms in inductively coupled molecular gas plasmas are explored with PlasmaTemp(TM), a novel "on-wafer" diagnostic tool. Experimental wafer measurements are obtained with the PlasmaTemp(TM) wafer processed in argon (Ar) and argon-oxygen (Ar/O2) mixed plasmas. Wafer heating mechanisms were determined by combining the experimental measurements with a 3-dimensional heat transfer model of the wafer. Comparisons between pure Ar and Ar/O2 plasmas demonstrate that two additional wafer heating mechanisms can be important in molecular gas plasmas compared to atomic gas discharges. Thermal heat conduction from the neutral gas and O-atom recombination on wafer surface can contribute as much as 60% to wafer heating under conditions of low-energy ion bombardment in molecular plasmas. Measurements of a second novel "on-wafer" diagnostic sensor, the PlasmaVolt(TM), were tested and validated in the ICP system for Ar plasmas varying in power and pressure. Sensor measurements were interpreted with a numerical sheath simulation and comparison to scaling laws derived from the inhomogeneous sheath model. The study demonstrates sensor measurements are proportional to the RF-current through the sheath and the scaling is a function of sheath impedance. PlasmaVolt(TM) sensor measurements are proportional to the

  12. Atmospheric Pressure Plasma Based Flame Control and Diagnostics

    Science.gov (United States)

    2015-01-01

    TYPE 3. DATES COVERED 00-00-2015 to 00-00-2015 4. TITLE AND SUBTITLE Atmospheric Pressure Plasma Based Flame Control and Diagnostics 5a...to 10%)  Flame speed enhancement (>20%)  Extension of lean limit (factor of two)  Distributed ignition  Development of new diagnostics

  13. Plasma diagnostics in a pulsed accelerator used for material processing

    Energy Technology Data Exchange (ETDEWEB)

    Zhukeshov, A [Science Research Institute of Experimental and Theoretical Physics, al-Farabi Kazakh National University, 96a Tole bi str., 050012 Almaty (Kazakhstan)

    2007-04-15

    Results of research work of a pulsed plasma accelerator, designed as diagnostic and material science stands in SRIETP are presented. We present results on the development of electric and magnetic probes used for measurement of plasma parameters. The physical properties and changes in structure of vanadium alloy, common quality carbon and stainless steels have been investigated as well.

  14. Development of innovative thermal plasma and particle diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Bachmann, Benjamin-Leon

    2013-09-24

    Three original plasma diagnostic systems have been developed to investigate transient three-dimensional plasma processes with high spatial and temporal resolution. The developed diagnostics have been analyzed and tested by increasing the complexity from a stationary free burning Argon arc to a dc pulsed process and finally to a transient gas metal arc including droplet transfer through the plasma. The transient plasma parameters that have been determined include three-dimensional axially symmetric plasma densities (n{sub e}, n{sub A}, n{sub A+}, n{sub A++}), electron temperatures (T{sub e}), electrical conductivities (σ{sub el}), magnetic flux densities (B) and current densities (j{sub el}). In the case of a droplet transfer through an arc consisting of an Iron/Argon plasma, the droplet density, surface tension, viscosity, and temperature have been determined.

  15. Status and challenges in electrical diagnostics of processing plasmas

    DEFF Research Database (Denmark)

    Stamate, Eugen

    2014-01-01

    Dry processing based on reactive plasmas was the main driven force for micro- and recently nano-electronic industry. Once with the increasing in plasma complexity new diagnostics methods have been developed to ensure a proper process control during etching, thin film deposition, ion implantation...... or other steps in device fabrication. This work reviews some of the unconventional methods developed in the last two decays to measure the parameters of reactive plasmas including, the test function method, thermal probes, and plasma-sheath-lens probes. The negative ion detection and surface contamination...... in plasmas with a high degree of contamination are also addressed. (C) 2014 Elsevier B.V. All rights reserved....

  16. Workshop on extremely high energy density plasmas and their diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Shozo (ed.)

    2001-09-01

    Compiled are the papers presented at the workshop on 'Extremely High Energy Density Plasmas and Their Diagnostics' held at National Institute for Fusion Science. The papers cover physics and applications of extremely high-energy density plasmas such as dense z-pinch, plasma focus, and intense pulsed charged beams. Separate abstracts were presented for 7 of the papers in this report. The remaining 25 were considered outside the subject scope of INIS. (author)

  17. Irradiation effects on plasma diagnostic components

    Energy Technology Data Exchange (ETDEWEB)

    Nishitani, Takeo [ed.] [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Iida, Toshiyuki; Ikeda, Yujiro [and others

    1998-10-01

    One of the most important issues to develop the diagnostics for the experimental thermonuclear reactor such as ITER is the irradiation effects on the diagnostics components. Typical neutron flux and fluence on the first wall are 1 MW/m{sup 2} and 1 MWa/m{sup 2}, respectively for ITER. In such radiation condition, most of the present diagnostics could not survive so that those will be planed to be installed far from the vacuum vessel. However, some diagnostics sensors such as bolometers and magnetic probes still have to be install inside vessel. And many transmission components for lights, wave and electric signals are inevitable even inside vessel. As a part of this R and D program of the ITER Engineering Design Activities (EDA), we carried out the irradiation tests on the basic materials of the transmission components and in-vessel diagnostics sensors in order to identify radiation hardened materials that can be used for diagnostic systems. (J.P.N.)

  18. Laser-aided diagnostics of plasmas and gases

    CERN Document Server

    Muraoka, K

    2000-01-01

    Updated and expanded from the original Japanese edition, Laser-Aided Diagnostics of Gases and Plasmas takes a unique approach in treating laser-aided diagnostics. The book unifies the subject by joining applications instead of describing each application as a totally separate system. In taking this approach, it highlights the relative strengths of each method and shows how they can complement each other in the study of gases and plasmas.The first part of the book presents a general introduction to the laser-aided study of gases and plasmas, including the various principles and hardware needed for each method, while the second part describes the applications of each general system in detail.Beneficial to a wide spectrum of academic and industrial researchers, this book provides a solid examination of the various options and methods available when involved in the analysis and diagnostics of gases and plasmas.

  19. Spectra of neutral carbon for plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J.G.; Kato, M.; Kato, T.

    2000-10-01

    Recently, carbon pellet experiments have been performed on W-7AS and a few CI lines have been observed in the situation of the pellet cloud from the cold dense plasma to hot ambient plasma. In so large varied conditions, the collisional radiative (CR) model is needed to study the spectra. In this article, a CR model including 79 states with n {<=} 6 and l {<=} 4 is developed, and then the line spectra and line intensity ratios are evaluated in the ionizing and recombining plasma, respective. (author)

  20. Diagnostics in ? helicon plasmas for ? deposition

    Science.gov (United States)

    Granier, A.; Nicolazo, F.; Vallée, C.; Goullet, A.; Turban, G.; Grolleau, B.

    1997-05-01

    0963-0252/6/2/008/img3 and 0963-0252/6/2/008/img4 helicon plasmas used for plasma enhanced chemical vapour deposition of 0963-0252/6/2/008/img5 films are investigated in the 1 - 10 mTorr pressure and 0 - 800 W rf power ranges. The positive oxygen ions are analysed by energy selective mass spectrometry and Langmuir probes. The oxygen atom concentration is monitored by actinometry and ionization threshold mass spectrometry. In oxygen plasmas it is shown that 0963-0252/6/2/008/img6 is the major positive ion, and that the oxygen molecules are far from being completely dissociated, due to a very high oxygen atom recombination frequency on the reactor walls. The dissociation degree increases with the rf power reaching 10% at 500 W. In 0963-0252/6/2/008/img4 plasmas, the plasma density and electron temperature decrease as the TEOS fraction increases. In contrast, the degree of oxygen dissociation increases sharply with the addition of a few per cent TEOS, is maximum for about 5% TEOS and decreases as TEOS fraction is further increased. In a 95:5 0963-0252/6/2/008/img4 plasma (5 mTorr, 300 W) the fluxes of oxygen positive ions and atoms impinging onto a floating substrate are estimated to be 0963-0252/6/2/008/img9 and 0963-0252/6/2/008/img10 respectively. Under these plasma conditions, near-stoichiometric 0963-0252/6/2/008/img11 films, with low OH content, are deposited at ambient temperature. The corresponding atom to ion flux ratio is about 250, which suggests the dominant role of oxygen atoms in the deposition kinetics. The comparison of the compositions of layers grown in a 5 mTorr 95:5 0963-0252/6/2/008/img4 plasma at two rf powers confirms the major role of oxygen atoms.

  1. Status and challenges in electrical diagnostics of processing plasmas

    DEFF Research Database (Denmark)

    Stamate, Eugen

    Reactive plasmas produced in oxygen, nitrogen, hydrogen and other complex gas mixture are used for various applications including thin films, etching, ion implantation, ashing, particles growth, oxidation and other surface functionalization processes. Most of the reactive gases are also...... the possibility to control and use these plasmas for processing. Development of reactive plasma sources for both applications and basic science is rather challenging and some of these efforts will be presented in direct correlation with diagnostic approaches....... electronegative so that, the role of negative ions cannot be neglected. The continuous decrease of the features size in micro- and nanoelectronic industry requires a precise control of plasma parameters including the negative ions. Despite of a good progress in plasma diagnostics, yet more is to be done...

  2. No diagnostic value of plasma clusterin in Alzheimer's disease.

    Directory of Open Access Journals (Sweden)

    Edina Silajdžić

    Full Text Available There is an urgent need for biomarkers to enable early diagnosis of Alzheimer's disease (AD. It has recently been shown that a variant within the clusterin gene is associated with increased risk of AD and plasma levels of clusterin have been found to be associated with the risk of AD. We, therefore, investigated the diagnostic value of clusterin by quantifying clusterin using an ELISA in plasma from 171 controls, 127 patients with AD, 82 patients with other dementias and 30 patients with depression. We observed similar plasma clusterin levels in controls, AD patients and patients with other dementias, suggesting that plasma clusterin levels have no diagnostic value for AD. There was a slight, but significant, increase in plasma clusterin in patients with depression compared to all other groups tested, which may warrant further investigation.

  3. Optical diagnostics of femtosecond laser plasmas

    Institute of Scientific and Technical Information of China (English)

    LI; Yutong

    2001-01-01

    [1]Benattar, R., Popovics, C., Sigel, R., Polarized light interferometer for laser fusion studies, Rev. Sci. Instrum., 979, 50(2): 583.[2]Young, P. E., Hammer, J. H., Wilks, S. C. et al., Laser beam propagation and channel formation in underdense plasmas, Phys. Plasmas, 995, 2(7): 2825.[3]Zhang, P., He, J.T., Chen, D.B. et al., Effects of a prepulse on γ-ray radiation produced by a femtosecond laser with only mJ energy, Phys. Rev. E., 998, 57: R3746.[4]Stamper, J. A., Review on spontaneous magnetic fields in laser-produced plasmas: phenomena and measurements, Laser and Particle Beams, 99, 9(4): 84.[5]Stamper, J. A., McLean, E. A., Ripin, B. H., Studies of spontaneous magnetic fields in laser-produced plasmas by Faraday rotation, Phys. Rev. Lett., 978, 40(8): 77.[6]Raven, A., Willi, O., Rumsby, P. T., Megagauss magnetic field profiles in laser-produced plasmas, Phys. Rev. Lett., 978, 4(8): 554.[7]Burgess, M. D. J., Luther-Davis, B., Nugent, K. A., An experimental study of magnetic fields in plasmas created by high intensity one micron laser radiation, Phys. Fluids, 985, 28(7): 2286.[8]Borghesi, M., Mackinnon, A. J., Bell, A. R. et al., Megagauss magnetic field generation and plasma jet formation on solid targets irradiated by an ultraintense picosecond laser pulse, Phys. Rev. Lett., 998, 8(): 2.

  4. Physicians' use of plasma methylmalonic acid as a diagnostic tool

    DEFF Research Database (Denmark)

    Hvas, A M; Vestergaard, H; Gerdes, Lars Ulrik;

    2000-01-01

    : This lack of response to an increased plasma methylmalonic acid raises an important question. Is the clinical response inadequate, or is the connection between an increased level of plasma methylmalonic acid and signs of clinical significant cobalamin deficiency less clear?......OBJECTIVES: To investigate physicians' reasons for requesting plasma methylmalonic acid and their reactions to an increased concentration of plasma methylmalonic acid. DESIGN: Study of medical records. SETTING: Three somatic district hospitals in Denmark. SUBJECTS: Medical records of 198 patients...... with a plasma methylmalonic acid measurement above the reference interval. Information on diagnostic decisions was available for 177 patients. MAIN OUTCOME MEASURES: Reasons for requesting plasma methylmalonic acid and the reactions to the finding of elevated plasma methylmalonic acid. RESULTS: An explicit...

  5. Microwave-plasma interactions studied via mode diagnostics in ALPHA

    Science.gov (United States)

    Friesen, T.; Andresen, G. B.; Ashkezari, M. D.; Baquero-Ruiz, M.; Bertsche, W.; Bowe, P. D.; Butler, E.; Cesar, C. L.; Chapman, S.; Charlton, M.; Eriksson, S.; Fajans, J.; Fujiwara, M. C.; Gill, D. R.; Gutierrez, A.; Hangst, J. S.; Hardy, W. N.; Hayano, R. S.; Hayden, M. E.; Humphries, A. J.; Hydomako, R.; Jonsell, S.; Kurchaninov, L.; Madsen, N.; Menary, S.; Nolan, P.; Olchanski, K.; Olin, A.; Povilus, A.; Pusa, P.; Robicheaux, F.; Sarid, E.; Silveira, D. M.; So, C.; Storey, J. W.; Thompson, R. I.; van der Werf, D. P.; Wurtele, J. S.; Yamazaki, Y.

    The goal of the ALPHA experiment is the production, trapping and spectroscopy of antihydrogen. A direct comparison of the ground state hyperfine spectra in hydrogen and antihydrogen has the potential to be a high-precision test of CPT symmetry. We present a novel method for measuring the strength of a microwave field for hyperfine spectroscopy in a Penning trap. This method incorporates a non-destructive plasma diagnostic system based on electrostatic modes within an electron plasma. We also show how this technique can be used to measure the cyclotron resonance of the electron plasma, which can potentially serve as a non-destructive measurement of plasma temperature.

  6. THz time-domain spectroscopy for tokamak plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Causa, F.; Zerbini, M.; Buratti, P.; Gabellieri, L.; Pacella, D.; Romano, A.; Tuccillo, A. A.; Tudisco, O. [ASSOCIAZIONE EURATOM ENEA sulla Fusione, C. R. Frascati, via E. Fermi 45, 00044 Frascati (Roma) (Italy); Johnston, M. [Clarendon Laboratory, Department of Physics, University of Oxford, Parks Road, Oxford OX1 3PU (United Kingdom); Doria, A.; Gallerano, G. P.; Giovenale, E. [ENEA C.R. Frascati UTAPRAD, via E. Fermi 45, 00044 Frascati (Roma) (Italy)

    2014-08-21

    The technology is now becoming mature for diagnostics using large portions of the electromagnetic spectrum simultaneously, in the form of THz pulses. THz radiation-based techniques have become feasible for a variety of applications, e.g., spectroscopy, imaging for security, medicine and pharmaceutical industry. In particular, time-domain spectroscopy (TDS) is now being used also for plasma diagnostics in various fields of application. This technique is promising also for plasmas for fusion applications, where plasma characteristics are non-uniform and/or evolve during the discharge This is because THz pulses produced with femtosecond mode-locked lasers conveniently span the spectrum above and below the plasma frequency and, thus, can be used as very sensitive and versatile probes of widely varying plasma parameters. The short pulse duration permits time resolving plasma characteristics while the large frequency span permits a large dynamic range. The focus of this work is to present preliminary experimental and simulation results demonstrating that THz TDS can be realistically adapted as a versatile tokamak plasma diagnostic technique.

  7. Recent results on ITER plasma equilibrium diagnostics and identification

    Energy Technology Data Exchange (ETDEWEB)

    Albanese, R.; Coccorese, E.; Morabito, F.C.; Pironti, A.; Versaci, M. [Associazione CREATE/ENEA/EURATOM - DIMET, Loc. Feo di Vito, Reggio Calabria (Italy); Mc Carthy, P.J. [Cork Univ. College (Ireland). Physics Dept.

    1998-07-01

    The most recent results achieved by our work-group on the plasma shape and position identification problem as well as on the interpretation of magnetic diagnostics are presented. The proposed test cases are related to the most recent configuration of sensors and geometry specification available from ITER. One of the aims of the work is also to give some design directions about the problem of optimal selection of the diagnostics for control parameters. (author)

  8. Vertical Electron Cyclotron Emission Diagnostic for TCV Plasmas

    Directory of Open Access Journals (Sweden)

    Goodman T. P.

    2012-09-01

    Full Text Available Electron cyclotron resonance heating (ECRH and electron cyclotron current drive (ECCD are used to heat the plasma, to tailor the current profiles and to achieve different operating regimes of tokamak plasmas. Plasmas with ECRH/ECCD are characterized by non-thermal electrons, which cannot be described by a Maxwellian distribution. Non-thermal electrons are also generated during MHD activity, like sawteeth crashes. Quantifying the non-thermal electron distribution is therefore a key for understanding EC heated fusion plasmas. For this purpose a vertical electron cyclotron emission (V-ECE diagnostic is being installed at TCV. The diagnostic layout, the calibration, the analysis technique for data interpretation, the physics potentials and limitations are discussed.

  9. Plasma diagnostics using synchrotron radiation in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Fidone, I.; Giruzzi, G.; Granata, G.

    1995-09-01

    This report deal with the use of synchrotron radiation in tokamaks. The main advantage of this new method is that it enables to overcome several deficiencies, caused by cut-off, refraction, and harmonic overlap. It also makes it possible to enhance the informative contents of the familiar low harmonic scheme. The basic theory of the method is presented and illustrated by numerical applications, for plasma parameters of relevance in present and next step tokamaks. (TEC). 10 refs., 13 figs.

  10. Signal processing methods for MFE plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Candy, J.V.; Casper, T.; Kane, R.

    1985-02-01

    The application of various signal processing methods to extract energy storage information from plasma diamagnetism sensors occurring during physics experiments on the Tandom Mirror Experiment-Upgrade (TMX-U) is discussed. We show how these processing techniques can be used to decrease the uncertainty in the corresponding sensor measurements. The algorithms suggested are implemented using SIG, an interactive signal processing package developed at LLNL.

  11. Flush-mounted probe diagnostics for argon glow discharge plasma

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Liang, E-mail: xld02345@mail.ustc.edu.cn; Cao, Jinxiang; Liu, Yu; Wang, Jian; Du, Yinchang; Zheng, Zhe; Zhang, Xiao; Wang, Pi [Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Zhang, Jin; Li, Xiao; Qin, Yongqiang; Zhao, Liang [Science and Technology on Space Physics Laboratory, Beijing 100076 (China)

    2014-09-15

    A comparison is made between plasma parameters measured by a flush-mounted probe (FP) and a cylindrical probe (CP) in argon glow discharge plasma. Parameters compared include the space potential, the plasma density, and the effective electron temperature. It is found that the ion density determined by the FP agrees well with the electron density determined by the CP in the quasi-neutral plasma to better than 10%. Moreover, the space potential and effective electron temperature calculated from electron energy distribution function measured by the FP is consistent with that measured by the CP over the operated discharge current and pressure ranges. These results present the FP can be used as a reliable diagnostic tool in the stable laboratory plasma and also be anticipated to be applied in other complicated plasmas, such as tokamaks, the region of boundary-layer, and so on.

  12. Ultrafast Diagnostics for Electron Beams from Laser Plasma Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Matlis, N. H.; Bakeman, M.; Geddes, C. G. R.; Gonsalves, T.; Lin, C.; Nakamura, K.; Osterhoff, J.; Plateau, G. R.; Schroeder, C. B.; Shiraishi, S.; Sokollik, T.; van Tilborg, J.; Toth, Cs.; Leemans, W. P.

    2010-06-01

    We present an overview of diagnostic techniques for measuring key parameters of electron bunches from Laser Plasma Accelerators (LPAs). The diagnostics presented here were chosen because they highlight the unique advantages (e.g., diverse forms of electromagnetic emission) and difficulties (e.g., shot-to-shot variability) associated with LPAs. Non destructiveness and high resolution (in space and time and energy) are key attributes that enable the formation of a comprehensive suite of simultaneous diagnostics which are necessary for the full characterization of the ultrashort, but highly-variable electron bunches from LPAs.

  13. Plasma-driven ultrashort bunch diagnostic

    CERN Document Server

    Dornmair, I; Floettmann, K; Marchetti, B; Maier, A R

    2016-01-01

    Ultrashort electron bunches are crucial for an increasing number of applications, however, diagnosing their longitudinal phase space remains a challenge. We propose a new method that harnesses the strong electric fields present in a laser driven plasma wakefield. By transversely displacing driver laser and witness bunch, a streaking field is applied to the bunch. This field maps the time information to a transverse momentum change and, consequently, to a change of transverse position. We illustrate our method with simulations where we achieve a time resolution in the attosecond range.

  14. Plasma-driven ultrashort bunch diagnostics

    Science.gov (United States)

    Dornmair, I.; Schroeder, C. B.; Floettmann, K.; Marchetti, B.; Maier, A. R.

    2016-06-01

    Ultrashort electron bunches are crucial for an increasing number of applications, however, diagnosing their longitudinal phase space remains a challenge. We propose a new method that harnesses the strong electric fields present in a laser driven plasma wakefield. By transversely displacing driver laser and witness bunch, a streaking field is applied to the bunch. This field maps the time information to a transverse momentum change and, consequently, to a change of transverse position. We illustrate our method with simulations where we achieve a time resolution in the attosecond range.

  15. Polarizer design for millimeter-wave plasma diagnostics

    DEFF Research Database (Denmark)

    Leipold, Frank; Salewski, Mirko; Jacobsen, Asger Schou

    2013-01-01

    Radiation from magnetized plasmas is in general elliptically polarized. In order to convert the elliptical polarization to linear polarization, mirrors with grooved surfaces are currently employed in our collective Thomson scattering diagnostic at ASDEX Upgrade. If these mirrors can be substituted...

  16. Near-infrared spectroscopy for burning plasma diagnostic applications.

    Science.gov (United States)

    Soukhanovskii, V A

    2008-10-01

    Ultraviolet and visible (UV-VIS, 200-750 nm) atomic spectroscopy of neutral and ionized fuel species (H, D, T, and Li) and impurities (e.g., He, Be, C, and W) is a key element of plasma control and diagnosis on International Thermonuclear Experimental Reactor and future magnetically confined burning plasma experiments (BPXs). Spectroscopic diagnostic implementation and performance issues that arise in the BPX harsh nuclear environment in the UV-VIS range, e.g., degradation of first mirror reflectivity under charge-exchange atom bombardment (erosion) and impurity deposition, permanent and dynamic loss of window, and optical fiber transmission under intense neutron and gamma-ray fluxes, are either absent or not as severe in the near-infrared (NIR, 750-2000 nm) range. An initial survey of NIR diagnostic applications has been undertaken on the National Spherical Torus Experiment. It is demonstrated that NIR spectroscopy can be used for machine protection and plasma control applications, as well as contribute to plasma performance evaluation and physics studies. Emission intensity estimates demonstrate that NIR measurements are possible in the BPX plasma operating parameter range. Complications in the NIR range due to the parasitic background emissions are expected to occur at very high plasma densities, low impurity densities, and at high plasma-facing component temperatures.

  17. Optical diagnostics of dusty plasmas during nanoparticle growth

    Science.gov (United States)

    Mikikian, M.; Labidi, S.; von Wahl, E.; Lagrange, J. F.; Lecas, T.; Massereau-Guilbaud, V.; Géraud-Grenier, I.; Kovacevic, E.; Berndt, J.; Kersten, H.; Gibert, T.

    2017-01-01

    Carbon-based thin films deposited on surfaces exposed to a typical capacitively-coupled RF plasma are sources of molecular precursors at the origin of nanoparticle growth. This growth leads to drastic changes of the plasma characteristics. Thus, a precise understanding of the dusty plasma structure and dynamics is required to control the plasma evolution and the nanoparticle growth. Optical diagnostics can reveal some particular features occurring in these kinds of plasmas. High-speed imaging of the plasma glow shows that instabilities induced by nanoparticle growth can be constituted of small brighter plasma regions (plasmoids) that rotate around the electrodes. A single bigger region of enhanced emission is also of particular interest: the void, a main central dust-free region, has very distinct plasma properties than the surrounding dusty region. This particularity is emphasized using optical emission spectroscopy with spatiotemporal resolution. Emission profiles are obtained for the buffer gas and the carbonaceous molecules giving insights on the changes of the electron energy distribution function during dust particle growth. Dense clouds of nanoparticles are shown to be easily formed from two different thin films, one constituted of polymer and the other one created by the plasma decomposition of ethanol.

  18. Advanced Plasma Diagnostic Analysis using Neural Networks

    Science.gov (United States)

    Tritz, Kevin; Reinke, Matt

    2016-10-01

    Machine learning techniques, specifically neural networks (NN), are used with sufficient internal complexity to develop an empirically weighted relationship between a set of filtered X-ray emission measurements and the electron temperature (Te) profile for a specific class of discharges on NSTX. The NN response matrix is used to calculate the Te profile directly from the filtered X-ray diode measurements which extends the electron temperature time response from the 60Hz Thomson Scattering profile measurements to fast timescales (>10kHz) and greatly expands the applicability of Te profile information to fast plasma phenomena, such as ELM dynamics. This process can be improved by providing additional information which helps the neural network refine the relationship between Te and the corresponding X-ray emission. NN supplement limited measurements of a particular quantity using related measurements with higher time or spatial resolution. For example, the radiated power (Prad) determined using resistive foil bolometers is related to similar measurements using AXUV diode arrays through a complex and slowly time-evolving quantum efficiency curve in the VUV spectral region. Results from a NN trained using Alcator C-Mod resistive foil bolometry and AXUV diodes are presented, working towards hybrid Prad measurements with the quantitative accuracy of resistive foil bolometers and with the enhanced temporal and spatial resolution of the unfiltered AXUV diode arrays. Work supported by Department of Energy Grant #: DE-FG02-09ER55012.

  19. Plasma diagnostics by means of electric probes; Diagnostico del plasma por medio de sondas electricas

    Energy Technology Data Exchange (ETDEWEB)

    Colunga S, S

    1991-04-15

    In this work a summary of the classical theoretical models to interpret the characteristic curve of a Langmuir electric probe placed in a plasma without magnetic field and with the one is made. The methodology for the electron temperature calculation and the density of the plasma in both cases is given, starting from the characteristic curve of the probe, as well as the approaches for the correct application of this diagnostic method of the plasma. (Author)

  20. Biomedical applications and diagnostics of atmospheric pressure plasma

    Science.gov (United States)

    Petrović, Z. Lj; Puač, N.; Lazović, S.; Maletić, D.; Spasić, K.; Malović, G.

    2012-03-01

    Numerous applications of non-equilibrium (cold, low temperature) plasmas require those plasmas to operate at atmospheric pressure. Achieving non-equilibrium at atmospheric pressure is difficult since the ionization growth is very fast at such a high pressure. High degree of ionization on the other hand enables transfer of energy between electrons and ions and further heating of the background neutral gas through collisions between ions and neutrals. Thus, all schemes to produce non-equilibrium plasmas revolve around some form of control of ionization growth. Diagnostics of atmospheric pressure plasmas is difficult and some of the techniques cannot be employed at all. The difficulties stem mostly from the small size. Optical emission spectroscopy and laser absorption spectroscopy require very high resolution in order to resolve the anatomy of the discharges. Mass analysis is not normally applicable for atmospheric pressure plasmas, but recently systems with triple differential pumping have been developed that allow analysis of plasma chemistry at atmospheric pressures which is essential for numerous applications. Application of such systems is, however, not free from problems. Applications in biomedicine require minimum heating of the ambient air. The gas temperature should not exceed 40 °C to avoid thermal damage to the living tissues. Thus, plasmas should operate at very low powers and power control is essential. We developed unique derivative probes that allow control of power well below 1 W and studied four different sources, including dielectric barrier discharges, plasma needle, atmospheric pressure jet and micro atmospheric pressure jet. The jet operates in plasma bullet regime if proper conditions are met. Finally, we cover results on treatment of bacteria and human cells as well as treatment of plants by plasmas. Localized delivery of active species by plasmas may lead to a number of medical procedures that may also involve removal of bacteria, fungi and

  1. Evaluation of two-beam spectroscopy as a plasma diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Billard, B.D.

    1980-04-01

    A two-beam spectroscopy (TBS) system is evaluated theoretically and experimentally. This new spectroscopic technique uses correlations between components of emitted light separated by a small difference in angle of propagation. It is thus a non-perturbing plasma diagnostic which is shown to provide local (as opposed to line-of-sight averaged) information about fluctuations in the density of light sources within a plasma - information not obtainable by the usual spectroscopic methods. The present design is an improvement on earlier systems proposed in a thesis by Rostler.

  2. Remote network control plasma diagnostic system for Tokamak T-10

    Science.gov (United States)

    Troynov, V. I.; Zimin, A. M.; Krupin, V. A.; Notkin, G. E.; Nurgaliev, M. R.

    2016-09-01

    The parameters of molecular plasma in closed magnetic trap is studied in this paper. Using the system of molecular diagnostics, which was designed by the authors on the «Tokamak T-10» facility, the radiation of hydrogen isotopes at the plasma edge is investigated. The scheme of optical radiation registration within visible spectrum is described. For visualization, identification and processing of registered molecular spectra a new software is developed using MatLab environment. The software also includes electronic atlas of electronic-vibrational-rotational transitions for molecules of protium and deuterium. To register radiation from limiter cross-section a network control system is designed using the means of the Internet/Intranet. Remote control system diagram and methods are given. The examples of web-interfaces for working out equipment control scenarios and viewing of results are provided. After test run in Intranet, the remote diagnostic system will be accessible through Internet.

  3. Numerical calculation of charge exchange cross sections for plasma diagnostics

    Science.gov (United States)

    Mendez, Luis

    2016-09-01

    The diagnostics of impurity density and temperature in the plasma core in tokamak plasmas is carried out by applying the charge exchange recombination spectroscopy (CXRS) technique, where a fast beam of H atoms collides with the plasma particles leading to electron capture reactions with the impurity ions. The diagnostics is based on the emission of the excited ions formed in the electron capture. The application of the CXRS requires the knowledge of accurate state-selective cross sections, which in general are not accessible experimentally, and the calculation of cross sections for the high n capture levels, required for the diagnostics in the intermediate energy domain of the probe beam, is particularly difficult. In this work, we present a lattice numerical method to solve the time dependent Schrödinger equation. The method is based on the GridTDSE package, it is applicable in the wide energy range 1 - 500 keV/u and can be used to assess the accuracy of previous calculations. The application of the method will be illustrated with calculations for collisions of multiply charged ions with H. Work partially supported by project ENE2014-52432-R (Secretaria de Estado de I+D+i, Spain).

  4. Microwave and optical diagnostics in a gadolinium plasma; Diagnostics hyperfrequence et optique dans un plasma magnetise de gadolinium

    Energy Technology Data Exchange (ETDEWEB)

    Larousse, B. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. des Procedes d`Enrichissement]|[Conservatoire National des Arts et Metiers (CNAM), 75 - Paris (France)

    1997-12-31

    The optimization of the separation process of the gadolinium isotopes by Ion Cyclotron Resonance requires a precise knowledge of the physical characteristics of the plasma. Thus, two kinds of diagnostics have been developed: the first one to estimate the microwave power inside the source and the second one to measure the density of atomic and ionic of the gadolinium inside the plasma source and in front of the collector. Microwave diagnostic: A microstrip antenna has been designed and developed in order to characterize the microwave at 36 GHz frequency in the plasma source. The experimental results for different plasma regimes are presented. The measurements inside the plasma source show a maximum of microwave absorption for an argon pressure of 10{sup -4} mb (93% of absorption of the incident wave in the conditions of isotope separation). Laser absorption diagnostic: The theory of laser absorption in presence of a magnetic field is recalled and the first results are presented. In the spectral range between 560 and 620 nm, corresponding to high energy levels of gadolinium, no signal is obtained so that the density is below the detection limit 10{sup 10} cm{sup -3}. In the spectral range between 380 and 400 nm, two lines are observed, issue from the fundamental and metastable (633 cm{sup -1}) levels. The density of metastable level of gadolinium ions is about 10{sup 10} cm{sup -3} with a relative precision of 15 % and its variation is studied as a function of argon pressure, at different sections of the plasma column (source, collector). The achieved set of measurements has been performed in order to check the theoretical models. (author) 32 refs.

  5. Applying Quantum Cascade Laser Spectroscopy in Plasma Diagnostics

    Directory of Open Access Journals (Sweden)

    Jürgen Röpcke

    2016-07-01

    Full Text Available The considerably higher power and wider frequency coverage available from quantum cascade lasers (QCLs in comparison to lead salt diode lasers has led to substantial advances when QCLs are used in pure and applied infrared spectroscopy. Furthermore, they can be used in both pulsed and continuous wave (cw operation, opening up new possibilities in quantitative time resolved applications in plasmas both in the laboratory and in industry as shown in this article. However, in order to determine absolute concentrations accurately using pulsed QCLs, careful attention has to be paid to features like power saturation phenomena. Hence, we begin with a discussion of the non-linear effects which must be considered when using short or long pulse mode operation. More recently, cw QCLs have been introduced which have the advantage of higher power, better spectral resolution and lower fluctuations in light intensity compared to pulsed devices. They have proved particularly useful in sensing applications in plasmas when very low concentrations have to be monitored. Finally, the use of cw external cavity QCLs (EC-QCLs for multi species detection is described, using a diagnostics study of a methane/nitrogen plasma as an example. The wide frequency coverage of this type of QCL laser, which is significantly broader than from a distributed feedback QCL (DFB-QCL, is a substantial advantage for multi species detection. Therefore, cw EC-QCLs are state of the art devices and have enormous potential for future plasma diagnostic studies.

  6. Plasma characterization on carbon fiber cathode by spectroscopic diagnostics

    Institute of Scientific and Technical Information of China (English)

    Liu Lie; Li Li-Min; Xu Qi-Fu; Chang Lei; Wen Jian-Chun

    2009-01-01

    This paper mainly investigates plasma characterization on carbon fiber cathodes with and without cesium iodide (CsI) coating powered by a~300 ns,~200 kV accelerating pulse. It was found that the CsI layers can not only improve the diode voltage,but also maintain a stable perveance.This indicates a slowly changed diode gap or a low cathode plasma expansion velocity.By spectroscopic diagnostics,in the vicinity of the cathode surface the average plasma density and temperature were found to be~3×1014 cm-3 and~5 eV,respectively,for an electron current density of~40 A/cm2.Furthermore,there exists a multicomponent plasma expansion toward the anode.The plasma expansion velocity,corresponding to the carbon and hydrogen ions,is estimated to be~1.5 cm/μs.Most notably,Cs spectroscopic line was obtained only at the distance ≤0.5 mm from the cathode surface.Carbon and hydrogen ions are obtained up to the distance of 2.5 mm from the cathode surface.Cs ions almost remain at the vicinity of the cathode surface.These results show that the addition of Cal enables a slow cathode plasma expansion toward the anode,providing a positive prospect for developing long-pulse electron beam sources.

  7. Advanced targets, diagnostics and applications of laser-generated plasmas

    Science.gov (United States)

    Torrisi, L.

    2015-04-01

    High-intensity sub-nanosecond-pulsed lasers irradiating thin targets in vacuum permit generation of electrons and ion acceleration and high photon yield emission in non-equilibrium plasmas. At intensities higher than 1015 W/cm2 thin foils can be irradiated in the target-normal sheath acceleration regime driving ion acceleration in the forward direction above 1 MeV per charge state. The distributions of emitted ions in terms of energy, charge state and angular emission are controlled by laser parameters, irradiation conditions, target geometry and composition. Advanced targets can be employed to increase the laser absorption in thin foils and to enhance the energy and the yield of the ion acceleration process. Semiconductor detectors, Thomson parabola spectrometer and streak camera can be employed as online plasma diagnostics to monitor the plasma parameters, shot by shot. Some applications in the field of the multiple ion implantation, hadrontherapy and nuclear physics are reported.

  8. Filterscope edge plasma diagnostic for the W7-X stellarator

    Science.gov (United States)

    Harris, Jeffrey; Unterberg, Ezekial; Lore, Jeremy; Stephey, Laurie; Schmitz, Oliver; Wurden, Glen; Biedermann, Christoph; Krychowiak, Maciej; Koenig, Ralf

    2015-11-01

    W7-X is a large (R = 5.5m, a = 0.5m, B 10 MW) superconducting stellarator at the Max-Planck Institut für Plasmaphysik in Greifswald, Germany, which will begin plasma operations in the last quarter of 2015. We describe here the first measurements with a 24-channel filterscope diagnostic [E. A. Unterberg et al., Rev. Sci. Instrum. 83, 10D722, (2012)] of edge plasma characteristics and spectral emission from impurities near the test limiters installed for initial plasma experiments. These measurements, together with high resolution IR thermography imaging of the limiter, will be used as inputs for edge transport modeling using the EMC3 code [J. D. Lore et al., Nucl. Fusion 52, 0540 (2012)]. This work is sponsored by DOE Contract No. DE-AC05- 00OR22725 with UT-Battelle.

  9. High density plasmas and new diagnostics: An overview (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Celona, L., E-mail: celona@lns.infn.it; Gammino, S.; Mascali, D. [Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania (Italy)

    2016-02-15

    One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including “volume-integrated” X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a “pin-hole camera” has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines.

  10. High density plasmas and new diagnostics: An overview (invited).

    Science.gov (United States)

    Celona, L; Gammino, S; Mascali, D

    2016-02-01

    One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including "volume-integrated" X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a "pin-hole camera" has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines.

  11. Diagnostic for Plasma Enhanced Chemical Vapor Deposition and Etch Systems

    Science.gov (United States)

    Cappelli, Mark A.

    1999-01-01

    concentration, temperature, ion energy distribution, and electron number density. A wide variety of diagnostic techniques are under development through this consortium grant to measure these parameters. including molecular beam mass spectrometry (MBMS). Fourier transform infrared (FTIR) spectroscopy, broadband ultraviolet (UV) absorption spectroscopy, a compensated Langmuir probe. Additional diagnostics. Such as microwave interferometry and microwave absorption for measurements of plasma density and radical concentrations are also planned.

  12. PROMINENCE PLASMA DIAGNOSTICS THROUGH EXTREME-ULTRAVIOLET ABSORPTION

    Energy Technology Data Exchange (ETDEWEB)

    Landi, E. [Department of Atmospheric, Oceanic and Space Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Reale, F. [Dipartimento di Fisica e Chimica, Universita di Palermo, Piazza del Parlamento 1, I-90134 Palermo (Italy)

    2013-07-20

    In this paper, we introduce a new diagnostic technique that uses EUV and UV absorption to determine the electron temperature and column emission measure, as well as the He/H relative abundance of the absorbing plasma. If a realistic assumption on the geometry of the latter can be made and a spectral code such as CHIANTI is used, then this technique can also yield the absorbing plasma hydrogen and electron density. This technique capitalizes on the absorption properties of hydrogen and helium at different wavelength ranges and temperature regimes. Several cases where this technique can be successfully applied are described. This technique works best when the absorbing plasma is hotter than 15,000 K. We demonstrate this technique on AIA observations of plasma absorption during a coronal mass ejection eruption. This technique can be easily applied to existing observations of prominences and cold plasmas in the Sun from almost all space missions devoted to the study of the solar atmosphere, which we list.

  13. Optimized and Automated design of Plasma Diagnostics for Additive Manufacture

    Science.gov (United States)

    Stuber, James; Quinley, Morgan; Melnik, Paul; Sieck, Paul; Smith, Trevor; Chun, Katherine; Woodruff, Simon

    2016-10-01

    Despite having mature designs, diagnostics are usually custom designed for each experiment. Most of the design can be now be automated to reduce costs (engineering labor, and capital cost). We present results from scripted physics modeling and parametric engineering design for common optical and mechanical components found in many plasma diagnostics and outline the process for automated design optimization that employs scripts to communicate data from online forms through proprietary and open-source CAD and FE codes to provide a design that can be sent directly to a printer. As a demonstration of design automation, an optical beam dump, baffle and optical components are designed via an automated process and printed. Supported by DOE SBIR Grant DE-SC0011858.

  14. Solar Prominence Modelling and Plasma Diagnostics at ALMA Wavelengths

    Science.gov (United States)

    Rodger, Andrew; Labrosse, Nicolas

    2017-09-01

    Our aim is to test potential solar prominence plasma diagnostics as obtained with the new solar capability of the Atacama Large Millimeter/submillimeter Array (ALMA). We investigate the thermal and plasma diagnostic potential of ALMA for solar prominences through the computation of brightness temperatures at ALMA wavelengths. The brightness temperature, for a chosen line of sight, is calculated using the densities of electrons, hydrogen, and helium obtained from a radiative transfer code under non-local thermodynamic equilibrium (non-LTE) conditions, as well as the input internal parameters of the prominence model in consideration. Two distinct sets of prominence models were used: isothermal-isobaric fine-structure threads, and large-scale structures with radially increasing temperature distributions representing the prominence-to-corona transition region. We compute brightness temperatures over the range of wavelengths in which ALMA is capable of observing (0.32 - 9.6 mm), however, we particularly focus on the bands available to solar observers in ALMA cycles 4 and 5, namely 2.6 - 3.6 mm (Band 3) and 1.1 - 1.4 mm (Band 6). We show how the computed brightness temperatures and optical thicknesses in our models vary with the plasma parameters (temperature and pressure) and the wavelength of observation. We then study how ALMA observables such as the ratio of brightness temperatures at two frequencies can be used to estimate the optical thickness and the emission measure for isothermal and non-isothermal prominences. From this study we conclude that for both sets of models, ALMA presents a strong thermal diagnostic capability, provided that the interpretation of observations is supported by the use of non-LTE simulation results.

  15. Polarizer design for millimeter-wave plasma diagnostics.

    Science.gov (United States)

    Leipold, F; Salewski, M; Jacobsen, A S; Jessen, M; Korsholm, S B; Michelsen, P K; Nielsen, S K; Stejner, M

    2013-08-01

    Radiation from magnetized plasmas is in general elliptically polarized. In order to convert the elliptical polarization to linear polarization, mirrors with grooved surfaces are currently employed in our collective Thomson scattering diagnostic at ASDEX Upgrade. If these mirrors can be substituted by birefringent windows, the microwave receivers can be designed to be more compact at lower cost. Sapphire windows (a-cut) as well as grooved high density polyethylene windows can serve this purpose. The sapphire window can be designed such that the calculated transmission of the wave energy is better than 99%, and that of the high density polyethylene can be better than 97%.

  16. Streak Tubes for Diagnostics of Lasers and Plasmas

    Science.gov (United States)

    Sokolov, A. Yu; Konovalov, P. I.; Nurtdinov, R. I.; Vikulin, M. P.; Pryanishnikov, I. G.; Dolotov, A. S.; Krapiva, P. S.

    2016-09-01

    Designing a facility for laser fusion research requires sufficient advancement in diagnostics techniques for lasers and plasmas, including those involving streak camera imaging. Maximum specifications of streak cameras depend on the parameters of streak tubes. The paper illustrates how these devices function, and which of their parameters are limiting. The paper presents a novel technological platform designed at VNIIA, which was used to develop a new generation of streak tubes. Using these streak tubes in streak cameras, the efficiency of streak camera imaging techniques can be improved by several orders of magnitude, and new techniques can be designed.

  17. Broadband notch filter design for millimeter-wave plasma diagnostics

    DEFF Research Database (Denmark)

    Furtula, Vedran; Michelsen, Poul; Leipold, Frank;

    2010-01-01

    Notch filters are integrated in plasma diagnostic systems to protect millimeter-wave receivers from intensive stray radiation. Here we present a design of a notch filter with a center frequency of 140 GHz, a rejection bandwidth of ∼ 900 MHz, and a typical insertion loss below 2 dB in the passband...... of ±9 GHz. The design is based on a fundamental rectangular waveguide with eight cylindrical cavities coupled by T-junction apertures formed as thin slits. Parameters that affect the notch performance such as physical lengths and conductor materials are discussed. The excited resonance mode...

  18. Automatization of hardware configuration for plasma diagnostic system

    Science.gov (United States)

    Wojenski, A.; Pozniak, K. T.; Kasprowicz, G.; Kolasinski, P.; Krawczyk, R. D.; Zabolotny, W.; Linczuk, P.; Chernyshova, M.; Czarski, T.; Malinowski, K.

    2016-09-01

    Soft X-ray plasma measurement systems are mostly multi-channel, high performance systems. In case of the modular construction it is necessary to perform sophisticated system discovery in parallel with automatic system configuration. In the paper the structure of the modular system designed for tokamak plasma soft X-ray measurements is described. The concept of the system discovery and further automatic configuration is also presented. FCS application (FMC/ FPGA Configuration Software) is used for running sophisticated system setup with automatic verification of proper configuration. In order to provide flexibility of further system configurations (e.g. user setup), common communication interface is also described. The approach presented here is related to the automatic system firmware building presented in previous papers. Modular construction and multichannel measurements are key requirement in term of SXR diagnostics with use of GEM detectors.

  19. Challenges in plasma and laser wakefield accelerated beams diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Cianchi, A., E-mail: alessandro.cianchi@roma2.infn.it [University of Rome Tor Vergata and INFN, V. della Ricerca Scientifica 1, 00133 Rome (Italy); Anania, M.P.; Bellaveglia, M.; Castellano, M.; Chiadroni, E.; Ferrario, M.; Gatti, G. [INFN-LNF - Via E. Fermi 40, 00044 Frascati (RM) (Italy); Marchetti, B. [DESY, Platanenallee 6, D-15738 Zeuthen (Germany); Mostacci, A. [University of Rome La Sapienza, P.le Aldo Moro 5, 00185 Rome (Italy); Pompili, R. [INFN-LNF - Via E. Fermi 40, 00044 Frascati (RM) (Italy); Ronsivalle, C. [ENEA C.R. Frascati, Via E. Fermi,45 00044 Frascati (RM) (Italy); Rossi, A.R.; Serafini, L. [INFN-Mi, Via Celoria, 16 20133 Milano (Italy)

    2013-08-21

    The new frontier in the particle beam accelerator is the so called plasma acceleration. Using the strong electric field inside a plasma it is possible to achieve accelerating gradients in the order of magnitude larger with respect to the actual technologies. Different schemes have been proposed and several already tested, producing beams of energy of several GeV. Mainly two approaches are followed: either the beam is directly produced by the interaction of a TW/PW class laser with a gas jet or a preexisting particle beam is accelerated in a plasma channel. In both cases a precise determination of the emerging beam parameters is mandatory for the fine tuning of the devices. The measurement of these parameters, in particular the emittance, is not trivial, mainly due to the large energy spread and to the tight focusing of these beams or to the background noise produced in the plasma channel. We show the problems related to the diagnostic of this kind of beams and the proposed or already realized solutions.

  20. Challenges in plasma and laser wakefield accelerated beams diagnostic

    Science.gov (United States)

    Cianchi, A.; Anania, M. P.; Bellaveglia, M.; Castellano, M.; Chiadroni, E.; Ferrario, M.; Gatti, G.; Marchetti, B.; Mostacci, A.; Pompili, R.; Ronsivalle, C.; Rossi, A. R.; Serafini, L.

    2013-08-01

    The new frontier in the particle beam accelerator is the so called plasma acceleration. Using the strong electric field inside a plasma it is possible to achieve accelerating gradients in the order of magnitude larger with respect to the actual technologies. Different schemes have been proposed and several already tested, producing beams of energy of several GeV. Mainly two approaches are followed: either the beam is directly produced by the interaction of a TW/PW class laser with a gas jet or a preexisting particle beam is accelerated in a plasma channel. In both cases a precise determination of the emerging beam parameters is mandatory for the fine tuning of the devices. The measurement of these parameters, in particular the emittance, is not trivial, mainly due to the large energy spread and to the tight focusing of these beams or to the background noise produced in the plasma channel. We show the problems related to the diagnostic of this kind of beams and the proposed or already realized solutions.

  1. Optical diagnostics for laser wakefields in plasma channels

    Science.gov (United States)

    Gaul, E. W.; Le Blanc, S. P.; Downer, M. C.

    1998-11-01

    Laser wakefield accelerators can excite large amplitude electrostatic fields (E >= 100 GV/m) which are potentially suitable for compact accelerators and advanced high energy colliders. An accurate diagnostic tool is necessary to test the physical effects in the wakefield predicted by theory and numerical simulations, and to have control over experiments. Frequency domain interferometry (FDI) (C. W. Siders et. al.), Phys. Rev. Lett. 76, 3570 (1995) has been developed in previous work. We experimentally demonstrate single-shot FDI as a sensitive diagnostic technique for probing laser wakefields. To generate wakefields longer than the diffraction limit, optical guiding of the laser pulse is necessary. An optical guide is formed by the hydrodynamic expansion of a cylindrical shock wave driven by a laser heated plasma, which is generated by laser pulse focused with an axicon lens (C. G. Durfee and H. M. Milchberg, Phys. Rev. Lett. 71, 2409 (1993)) to intensities of ~= 10^13 W/cm^2. These are too low to reach multi-photon ionization or significant collisional ionization in <= 1 atm helium. We preionize Helium gas with an electrical discharge for efficient inverse bremsstrahlung absorption of the laser pulse and formation of a plasma channel. Spatially resolved chirped pulse interferometry is used to measure the radial electron density profile of the channel.

  2. Electromagnetic Analysis of ITER Diagnostic Equatorial Port Plugs During Plasma Disruptions

    Energy Technology Data Exchange (ETDEWEB)

    Y. Zhai, R. Feder, A. Brooks, M. Ulrickson, C.S. Pitcher and G.D. Loesser

    2012-08-27

    ITER diagnostic port plugs perform many functionsincluding structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to the plasma. The design of diagnostic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate responses of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the Diagnostic First Walls (DFWs), Diagnostic Shield Modules (DSMs) and the EPP structure, as well as impact on the system design integration due to electrical contact among various EPP structural components are discussed.

  3. Establishing isokinetic flow for a plasma torch exhaust gas diagnostic for a plasma hearth furnace

    Energy Technology Data Exchange (ETDEWEB)

    Pollack, B.R.

    1996-05-01

    Real time monitoring of toxic metallic effluents in confined gas streams can be accomplished through use of Microwave Induced Plasmas to perform atomic emission spectroscopy, For this diagnostic to be viable it is necessary that it sample from the flowstream of interest in an isokinetic manner. A method of isokinetic sampling was established for this device for use in the exhaust system of a plasma hearth vitrification furnace. The flow and entrained particulate environment were simulated in the laboratory setting using a variable flow duct of the same dimensions (8-inch diameter, schedule 40) as that in the field and was loaded with similar particulate (less than 10 {mu}m in diameter) of lake bed soil typically used in the vitrification process. The flow from the furnace was assumed to be straight flow. To reproduce this effect a flow straightener was installed in the device. An isokinetic sampling train was designed to include the plasma torch, with microwave power input operating at 2.45 GHz, to match local freestream velocities between 800 and 2400 ft/sec. The isokinetic sampling system worked as planned and the plasma torch had no difficulty operating at the required flowrates. Simulation of the particulate suspension was also successful. Steady particle feeds were maintained over long periods of time and the plasma diagnostic responded as expected.

  4. Establishing isokinetic flow for a plasma torch exhaust gas diagnostic for a plasma hearth furnace

    Energy Technology Data Exchange (ETDEWEB)

    Pollack, Brian R. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    1996-05-01

    Real time monitoring of toxic metallic effluents in confined gas streams can be accomplished through use of Microwave Induced Plasmas to perform atomic emission spectroscopy, For this diagnostic to be viable it is necessary that it sample from the flowstream of interest in an isokinetic manner. A method of isokinetic sampling was established for this device for use in the exhaust system of a plasma hearth vitrification furnace. The flow and entrained particulate environment were simulated in the laboratory setting using a variable flow duct of the same dimensions (8-inch diameter, schedule 40) as that in the field and was loaded with similar particulate (less than 10 μm in diameter) of lake bed soil typically used in the vitrification process. The flow from the furnace was assumed to be straight flow. To reproduce this effect a flow straightener was installed in the device. An isokinetic sampling train was designed to include the plasma torch, with microwave power input operating at 2.45 GHz, to match local freestream velocities between 800 and 2400 ft/sec. The isokinetic sampling system worked as planned and the plasma torch had no difficulty operating at the required flowrates. Simulation of the particulate suspension was also successful. Steady particle feeds were maintained over long periods of time and the plasma diagnostic responded as expected.

  5. Diagnostic techniques for measuring suprathermal electron dynamics in plasmas (invited).

    Science.gov (United States)

    Coda, S

    2008-10-01

    Plasmas, both in the laboratory and in space, are often not in thermodynamic equilibrium, and the plasma electron distribution function is accordingly non-Maxwellian. Suprathermal electron tails can be generated by external drives, such as rf waves and electric fields, or internal ones, such as instabilities and magnetic reconnection. The variety and importance of the phenomena in which suprathermal electrons play a significant role explains an enduring interest in diagnostic techniques to investigate their properties and dynamics. X-ray bremsstrahlung emission has been studied in hot magnetized plasmas for well over two decades, flanked progressively by electron-cyclotron emission in geometries favoring the high-energy end of the distribution function (high-field-side, vertical, oblique emission), by electron-cyclotron absorption, by spectroscopic techniques, and at lower temperatures, by Langmuir probes and electrostatic analyzers. Continuous progress in detector technology and in measurement and analysis techniques, increasingly sophisticated layouts (multichannel and tomographic systems, imaging geometries), and highly controlled suprathermal generation methods (e.g., perturbative rf modulation) have all been brought to bear in recent years on an increasingly detailed, although far from complete, understanding of suprathermal electron dynamics.

  6. Development of Diagnostics for Large-Scale Experiments with Dense Magnetized Plasmas - MJ Plasma-focus diagnostics systems

    Energy Technology Data Exchange (ETDEWEB)

    Scholz, M.; Karpinski, L.; Paduch, M.; Pisarczyk, T.; Zielinska, E.; Chodukowski, T. [Institute of Plasma Physics and Laser Microfusion IPPLM, 01-497 Warsaw (Poland); Sadowski, M.J. [Institute of Plasma Physics and Laser Microfusion IPPLM, 01-497 Warsaw (Poland)] [The Andrzej Soltan Institute for Nuclear Studies IPJ, 05-400 Otwock-Swiert (Poland); Skladnik-Sadowska, E.; Czaus, K.; Kwiatkowski, R.; Malinowski, K. [The Andrzej Soltan Institute for Nuclear Studies IPJ, 05-400 Otwock-Swiert (Poland); Krauz, S. [RNC Kurchatov Institute, Moscow (Russian Federation); Mitrovanov, K. [FGUP GNC RF Triniti, Troick (Russian Federation)

    2011-07-01

    This document presents the diagnostics arrangements and interesting results of research on fusion pulsed plasma, which was generated within the large PF-1000 facility operated in the Institute of Plasma Physics and Laser Microfusion (Warsaw, Poland). Experimental studies were carried out with the following diagnostic techniques: 1) Rogovski coil for current measurements; 2) Four dI/dt probes in different places around the collector of PF-1000; 3) Voltage divider; 4) Mach-Zender interferometer (16 frames); 5) Fast scintillation probes for X-ray and neutron detection; 6) Silver activation counters; 7) Specially prepared current probes; 8) Thomson spectrometer for mass- and energy-analysis of deuterium beams; 9) Ion-pinhole cameras equipped with nuclear-track detectors, etc. The studies have been carried out with the pure deuterium filling, and particular attention was paid to correlations between the fast-neutron emission and an evolution of plasma parameters. The total fusion-neutron yield, as measured with four silver-activation counters, was found to be up to 7*10{sup 11} per shot, depending on the experimental conditions. Correlations of the neutron pulses with interferometric frame-pictures of the PF pinch column were studied. From time-of-flight (ToF) measurements of the fusion neutrons it was possible to estimate a CM velocity of deuterons involved in the D-D reactions. The fast fusion-produced protons have also been recorded and analyzed by means pinhole cameras and shielded track detectors. The document is composed of an abstract followed by the slides of the presentation. (authors)

  7. Electromagnetic Analysis For The Design Of ITER Diagnostic Port Plugs During Plasma Disruptions

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Y

    2014-03-03

    ITER diagnostic port plugs perform many functions including structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to plasma. The design of diagnotic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate response of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the Diagnostic First Walls (DFWs). Diagnostic Shield Modules (DSMs) and the EPP structure, as well as impact on the system design integration due to electrical contact among various EPP structural components are discussed.

  8. Electron beam charge diagnostics for laser plasma accelerators

    Directory of Open Access Journals (Sweden)

    K. Nakamura

    2011-06-01

    Full Text Available A comprehensive study of charge diagnostics is conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs. First, a scintillating screen (Lanex was extensively studied using subnanosecond electron beams from the Advanced Light Source booster synchrotron, at the Lawrence Berkeley National Laboratory. The Lanex was cross calibrated with an integrating current transformer (ICT for up to the electron energy of 1.5 GeV, and the linear response of the screen was confirmed for charge density and intensity up to 160  pC/mm^{2} and 0.4  pC/(ps  mm^{2}, respectively. After the radio-frequency accelerator based cross calibration, a series of measurements was conducted using electron beams from an LPA. Cross calibrations were carried out using an activation-based measurement that is immune to electromagnetic pulse noise, ICT, and Lanex. The diagnostics agreed within ±8%, showing that they all can provide accurate charge measurements for LPAs.

  9. Electron Beam Charge Diagnostics for Laser Plasma Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Kei; Gonsalves, Anthony; Lin, Chen; Smith, Alan; Rodgers, David; Donahue, Rich; Byrne, Warren; Leemans, Wim

    2011-06-27

    A comprehensive study of charge diagnostics is conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs). First, a scintillating screen (Lanex) was extensively studied using subnanosecond electron beams from the Advanced Light Source booster synchrotron, at the Lawrence Berkeley National Laboratory. The Lanex was cross calibrated with an integrating current transformer (ICT) for up to the electron energy of 1.5 GeV, and the linear response of the screen was confirmed for charge density and intensity up to 160 pC/mm{sup 2} and 0.4 pC/(ps mm{sup 2}), respectively. After the radio-frequency accelerator based cross calibration, a series of measurements was conducted using electron beams from an LPA. Cross calibrations were carried out using an activation-based measurement that is immune to electromagnetic pulse noise, ICT, and Lanex. The diagnostics agreed within {+-}8%, showing that they all can provide accurate charge measurements for LPAs.

  10. DIAGNOSTIC SPECTROSCOPIQUE EN TEMPERATURE ELECTRONIQUE DES PLASMAS PHOTOIONISES

    Directory of Open Access Journals (Sweden)

    A. K Ferouani

    2009-12-01

    Full Text Available In this work, we are interested in the diagnostics in electronic temperature of a plasma purely photoionized, based on the intensity ration of lines emitted by ions helium-like, witch have an atomic number Z relatively small. We considered the three lines corresponding to the transitions starting from the excited levels 1s2l towards the fundamental level 1s2 1S0, like appropriate lines. More precisely, the line of resonance w due to the transition 1s2p 1P1 1s2 1 S0, the line of intercombinaison (x,y 1s2p 3 P2,1 1s2 1 S0 as well as prohibited line z due to the transition 1s2 3 S1 1s2 1 S0. These lines appear clearly in the spectra of astrophysical plasmas. As helium-like ion, we chose two, the oxygen O6+ (Z=8 and neon Ne8+ (Z=10. We carried out calculations of the ration of lines intensity G=(zxy/w of O6+ and Ne8+ according to the electronic temperature in the range going from 105 to 107 K. We will see that, like it was shown by Gabriel and Jordan in 1969, this intensity ration can be very sensitive to the temperature electronic and practically independent of the electronic density. Consequently, the ration G can be used to determine in a reliable way the electronic temperature of plasma observed.

  11. TPX diagnostics for tokamak operation, plasma control and machine protection

    Energy Technology Data Exchange (ETDEWEB)

    Edmonds, P.H. [Texas Univ., Austin, TX (United States). Fusion Research Center; Medley, S.S.; Young, K.M. [Princeton Univ., NJ (United States). Plasma Physics Lab.] [and others

    1995-08-01

    The diagnostics for TPX are at an early design phase, with emphasis on the diagnostic access interface with the major tokamak components. Account has to be taken of the very severe environment for diagnostic components located inside the vacuum vessel. The placement of subcontracts for the design and fabrication of the diagnostic systems is in process.

  12. Neutral Beam Injection for Plasma and Magnetic FieldDiagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Vainionpaa, Jaakko Hannes; Leung, Ka Ngo; Kwan, Joe W.; Levinton,Fred

    2007-08-01

    At the Lawrence Berkeley National Laboratory (LBNL) adiagnostic neutral beam injection system for measuring plasma parameters,flow velocity, and local magnetic field is being developed. High protonfraction and small divergence is essential for diagnostic neutral beams.In our design, a neutral hydrogen beam with an 8 cm x 11 cm (or smaller)elliptical beam spot at 2.5 m from the end of the extraction column isproduced. The beam will deliver up to 5 A of hydrogen beam to the targetwith a pulse width of ~;1 s, once every 1 - 2 min. The H1+ ion species ofthe hydrogen beamwill be over 90 percent. For this application, we havecompared two types of RF driven multicusp ion sources operating at 13.56MHz. The first one is an ion source with an external spiral antennabehind a dielectric RF-window. The second one uses an internal antenna insimilar ion source geometry. The source needs to generate uniform plasmaover a large (8 cm x 5 cm) extraction area. We expect that the ion sourcewith internal antenna will be more efficient at producing the desiredplasma density but might have the issue of limited antenna lifetime,depending on the duty factor. For both approaches there is a need forextra shielding to protect the dielectric materials from the backstreaming electrons. The source walls will be made of insulator materialsuch as quartz that has been observed to generate plasma with higheratomic fraction than sources with metal walls. The ion beam will beextracted and accelerated by a set of grids with slits, thus forming anarray of 6 sheet-shaped beamlets. The multiple grid extraction will beoptimized using computer simulation programs. Neutralization of the beamwill be done in neutralization chamber, which has over 70 percentneutralization efficiency.

  13. Diagnostic evaluation of plasma aldosterone concentration to plasma renin activity ratio in primary aldosteronism

    Institute of Scientific and Technical Information of China (English)

    Huilan ZHANG; Daowen WANG

    2008-01-01

    Using the plasma aldosterone concentration to plasma renin activity ratio (PAC/PRA ratio) as the screening test of choice for primary aldosteronism in hypertensive patients, we studied the clinical character-istics and the diagnostic value of PAC/PRA ratio in primary aldosteronism. The plasma aldosterone concen-tration (PAC) and plasma renin activity (PRA) levels were measured by radioimmunoassay in 902 hypertensive patients from out-patient clinics or hospitals. One hundred and twenty-six suspected primary aldosteronism patients whose PAC/PRA ratio was > 25 ng/dL/ng/mL/ hr had a lamellar computed tomography (CT) scan in the adrenal gland and follow-up visits. The proportion of primary aldosteronism in hypertensive patients was 14% (126/902). There were 54 patients with unilateral or bilateral hyperplasia and 25 patients with adenoma according to the CT scan. 39% (49/126) of the patients with primary aldosteronism had hypokalemia. Twenty-five patients received surgical treatment. The efficacy and cure rates were 100% (25/25) and 48% (12/25), respect-ively. The effective rate of aldactone and the single-drug cure rate were 89% (48/54) and 24% (13/54), respectively. Primary aldosteronism affects over 10% of hypertensive patients in China. The PAC/PRA ratio can be considered as a routine screening test in hypertensives, especially resistant hypertensive patients and a high PAC/PRA ratio is an invaluable index in primary aldosteronism diagnosis.

  14. CO{sub 2} laser diagnostics for measurements of the plasma density profile and plasma density fluctuations on LHD

    Energy Technology Data Exchange (ETDEWEB)

    Vyacheslavov, L.N. [Budker Institute of Nuclear Physics, Novosibirsk (Russian Federation); Tanaka, K.; Kawahata, K. [National Inst. for Fusion Science, Toki, Gifu (Japan)

    2001-04-01

    A CO{sub 2} laser based diagnostics complimentary to the existing FIR interferometer is proposed. It combines interferometry for plasma density profile measurement under conditions of large density gradients, and both imaging and scattering techniques for observation of plasma fluctuations. Two-colour interferometer with a slablike probe beam and a single multichannel linear detector array provide observation of plasma density profile and density fluctuations at two locations along the probe beam. Basic characteristics of the diagnostics are considered as well as some effects that include dispersion and are critical for two colour imaging technique. The results of the bench-top experiments with the prototype of the interferometer are presented. (author)

  15. Second Topical Conference on High-Temperature Plasma Diagnostics

    Science.gov (United States)

    1978-02-01

    1 and is employed to make routine measurements of the evolution of plasma density in the high density ( n > 5 x 1011* cm-3) Alcator A tokamak...plasmas. To exemplify the use of these techniques in fusion plasmas, studies of density fluc- tuations in the ATC and ALCATOR tokamaks will be...character- istics for the excessive incidence of plasma light. Video signals are recorded with a video tape recorder, which starts and stops recording

  16. Present status on atomic and molecular data relevant to fusion plasma diagnostics and modeling

    Energy Technology Data Exchange (ETDEWEB)

    Tawara, H. [ed.

    1997-01-01

    This issue is the collection of the paper presented status on atomic and molecular data relevant to fusion plasma diagnostics and modeling. The 10 of the presented papers are indexed individually. (J.P.N.)

  17. Quantitative single shot and spatially resolved plasma wakefield diagnostics

    CERN Document Server

    Kasim, Muhammad Firmansyah; Ceurvorst, Luke; Levy, Matthew C; Ratan, Naren; Sadler, James; Bingham, Robert; Burrows, Philip N; Trines, Raoul; Wing, Matthew; Norreys, Peter

    2015-01-01

    Diagnosing plasma conditions can give great advantages in optimizing plasma wakefield accelerator experiments. One possible method is that of photon acceleration. By propagating a laser probe pulse through a plasma wakefield and extracting the imposed frequency modulation, one can obtain an image of the density modulation of the wakefield. In order to diagnose the wakefield parameters at a chosen point in the plasma, the probe pulse crosses the plasma at oblique angles relative to the wakefield. In this paper, mathematical expressions relating the frequency modulation of the laser pulse and the wakefield density profile of the plasma for oblique crossing angles are derived. Multidimensional particle-in-cell simulation results presented in this paper confirm that the frequency modulation profiles and the density modulation profiles agree to within 10%. Limitations to the accuracy of the measurement are discussed in this paper. This technique opens new possibilities to quantitatively diagnose the plasma wakefie...

  18. Development, diagnostic and applications of radio-frequency plasma reactor

    Science.gov (United States)

    Puac, N.

    2008-07-01

    In many areas of the industry, plasma processing of materials is a vital technology. Nonequilibrium plasmas proved to be able to produce chemically reactive species at a low gas temperature while maintaining highly uniform reaction rates over relatively large areas (Makabe and Petrovic 2006). At the same time nonequilibrium plasmas provide means for good and precise control of the properties of active particles that determine the surface modification. Plasma needle is one of the atmospheric pressure sources that can be used for treatment of the living matter which is highly sensitive when it comes to low pressure or high temperatures (above 40 C). Dependent on plasma conditions, several refined cell responses are induced in mammalian cells (Sladek et al. 2005). It appears that plasma treatment may find many biomedical applications. However, there are few data in the literature about plasma effects on plant cells and tissues. So far, only the effect of low pressure plasmas on seeds was investigated. It was shown that short duration pretreatments by non equilibrium low temperature air plasma were stimulative in light induced germination of Paulownia tomentosa seeds (Puac et al. 2005). As membranes of plants have different properties to those of animals and as they show a wide range of properties we have tried to survey some of the effects of typical plasma which is envisaged to be used in biotechnological applications on plant cells. In this paper we will make a comparison between two configurations of plasma needle that we have used in treatment of biological samples (Puac et al. 2006). Difference between these two configurations is in the additional copper ring that we have placed around glass tube at the tip of the needle. We will show some of the electrical characteristics of the plasma needle (with and without additional copper ring) and, also, plasma emission intensity obtained by using fast ICCD camera.

  19. Plasma Diagnostic and Performance of a Permanent Magnet Hall Thruster

    CERN Document Server

    Ferreira, J L; Rego, I D S; Ferreira, I S; Ferreira, Jose Leonardo; Souza, Joao Henrique Campos De; Rego, Israel Da Silveira; Ferreira, Ivan Soares

    2004-01-01

    Electric propulsion is now a sucessfull method for primary propulsion of deep space long duration missions and for geosyncronous satellite attitude control. Closed Drift Plasma Thruster, so called Hall Thruster or SPT (stationary plasma thruster) were primarily conceived in USSR (the ancient Soviet Union) and now it is been developed by space agencies, space research institutes and industries in several countries such as France, USA, Israel, Russian Federation and Brazil. In this work, we show plasma characteristics and performance of a Hall Thruster designed with an innovative concept which uses an array of permanent magnets, instead of an eletromagnet, to produce a radial magnetic field inside its cylindrical plasma drift channel. Within this new concept, we expect to develop a Hall Thruster within power consuption that will scale up to small and medium size satellites. A plasma density and temperature space profiles inside and outside the thruster channel will be shown. Space plasma potential, ion temperat...

  20. Magnetic Diagnostics For Equilibrium Reconstruction And Realtime Plasma Control In NSTX-Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Gerhardt, Stefan P. [PPPL; Erickson, Keith [PPPL; Kaita, Robert [PPPL; Lawson, John [PPPL; Mozulay, Robert [PPPL; Mueller, Dennis [PPPL; Que, Weiguo [PPPL; Rahman, Nabidur [PPPL; Schneider, Hans [PPPL; Smalley, Gustav [PPPL; Tresemer, Kelsey [PPPL

    2014-06-01

    This paper describes aspects of magnetic diagnostics for realtime control in NSTX-U. The sensor arrangement on the upgraded center column is described. New analog and digital circuitry for processing the plasma current rogowski data are presented. An improved algorithm for estimating the plasma vertical velocity for feedback control is presented.

  1. Plasma diagnostics approach to welding heat source/molten pool interaction

    Energy Technology Data Exchange (ETDEWEB)

    Key, J.F.; McIlwain, M.E.; Isaacson, L.

    1980-01-01

    Plasma diagnostic techniques show that weld fusion zone profile and loss of metal vapors from the molten pool are strongly dependent on both the intensity and distribution of the heat source. These plasma properties, are functions of cathode vertex angle and thermal conductivity of the shielding gas, especially near the anode.

  2. Diagnostics of Femtosecond Laser-Plasmas Using Fundamental and Second Harmonic Emission

    Institute of Scientific and Technical Information of China (English)

    ZHAO Li-Zeng; ZHANG Ping; FENG Bao-Hua; WEI Zhi-Yi; ZHANG Jie

    2000-01-01

    By observing the fundamental and second harmonic emission from a plasma produced by a 150 fs, 5 mJ laser at 800nm, the electron temperature, the expansion speed and the scalelength of the plasma have been diagnosed. Moreover the polarization of the fundamental and second harmonic emission has been studied. This could be a useful diagnostic for modulation at the critical surface of the plasma.

  3. Millimeter-wave receiver design for plasma diagnostics

    DEFF Research Database (Denmark)

    Leipold, Frank; Hansen, S. K.; Jacobsen, Asger Schou;

    2016-01-01

    Scattered millimeter waves entering from the collective Thomson scattering diagnostic at ASDEX Upgrade fusion device are generally elliptically polarized. In order to convert the millimeter waves to linearly polarized waves (required for the detector), birefringent window assemblies (sapphire) have...

  4. X-ray plasma diagnostics for totally and partially photoionized plasmas such as Warm Absorber in AGN

    CERN Document Server

    Porquet, D; Porquet, Delphine; Dubau, Jacques

    1999-01-01

    Thanks to the new generation of X-ray satellites such as Chandra and XMM, high resolution and high sensitivity spectra are available. In particular, for the first time, the three most intense lines (resonance, intercombination and forbidden) of low charged (low Z) He-like ions are splitted for non solar plasmas. We present density, ionizing process and temperature diagnostics, for totally and partially photoionized plasmas, based on ratios of these three lines. These powerful plasma diagnostics could be used for hot astrophysical plasmas such as AGN, starburst galaxies, X-ray binaries, etc. In particular, they could be applied to Warm Absorber often seen in Active Galactic Nuclei (Porquet & Dubau 2000), which is an important key tool to understand central region of different types of AGN (Seyfert 1 and 2, high and low redshift quasars).

  5. Fusion plasma diagnostics with mm-waves an introduction

    CERN Document Server

    Hartfuss, Hans-Jürgen

    2013-01-01

    Filling a gap in the literature, this introduction to the topic covers the physics of the standard microwave diagnostics established on modern fusion experiments, and the necessary technological background from the field of microwave engineering. Written by well-known mm-wave diagnosticians in the field of fusion physics, the textbook includes such major diagnostic techniques as electron cyclotron emission, interferometry, reflectometry, polarimetry, and scattering.

  6. Electromagnetic analysis of ITER diagnostic equatorial port plugs during plasma disruptions

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Y., E-mail: yzhai@pppl.gov [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Feder, R.; Brooks, A. [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Ulrickson, M. [Sandia National Laboratory, Albuquerque, NM (United States); Pitcher, C.S. [ITER Organization, Route de Vinon sur Verdon, St Paul lez Durance (France); Loesser, G.D. [Princeton Plasma Physics Laboratory, Princeton, NJ (United States)

    2013-10-15

    Highlights: ► Disruption loads on ITER diagnostic equatorial port plugs are extracted. ► Upward major disruption produces the largest radial moment and radial force on diagnostic first walls and diagnostic shield modules. ► Large eddy currents on supporting rails, keys and water pipes are observed during disruption. -- Abstract: ITER diagnostic port plugs perform many functions including structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to the plasma. The design of diagnostic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate responses of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the diagnostic first walls (DFWs), diagnostic shield modules (DSMs) and the EPP structure, as well as impact on the system design integration due to electrical contact among various EPP structural components are discussed.

  7. Diagnostics of MCF plasmas using Lyman-{alpha} fluorescence excited by one or two photons

    Energy Technology Data Exchange (ETDEWEB)

    Voslamber, D

    1998-11-01

    Laser-induced Lyman-{alpha} fluorescence of the hydrogen isotopes is investigated with regard to diagnostic applications in magnetically confined fusion plasmas. A formal analysis is presented for two excitation schemes: one-photon and Doppler-free two-photon excitation. The analysis includes estimates of the expected experimental errors arising from the photon noise and from the sensitivity of the observed fluorescence signals to variations of the plasma and laser parameters. Both excitation schemes are suitable primarily for application in the plasma edge, but even in the plasma bulk of large machines they can still be applied in combination with a diagnostic neutral beam. The two-photon excitation scheme is particularly attractive because it involves absorption spectra that are resolved within the Doppler width. This implies a large diagnostic potential and in particular offers a way to measure the deuterium-tritium fuel mix in fusion reactors. (author) 37 refs.

  8. Spectroscopic diagnostics of plasma during laser processing of aluminium

    Science.gov (United States)

    Lober, R.; Mazumder, J.

    2007-10-01

    The role of the plasma in laser-metal interaction is of considerable interest due to its influence in the energy transfer mechanism in industrial laser materials processing. A 10 kW CO2 laser was used to study its interaction with aluminium under an argon environment. The objective was to determine the absorption and refraction of the laser beam through the plasma during the processing of aluminium. Laser processing of aluminium is becoming an important topic for many industries, including the automobile industry. The spectroscopic relative line to continuum method was used to determine the electron temperature distribution within the plasma by investigating the 4158 Å Ar I line emission and the continuum adjacent to it. The plasmas are induced in 1.0 atm pure Ar environment over a translating Al target, using f/7 and 10 kW CO2 laser. Spectroscopic data indicated that the plasma composition and behaviour were Ar-dominated. Experimental results indicated the plasma core temperature to be 14 000-15 300 K over the incident range of laser powers investigated from 5 to 7 kW. It was found that 7.5-29% of the incident laser power was absorbed by the plasma. Cross-section analysis of the melt pools from the Al samples revealed the absence of any key-hole formation and confirmed that the energy transfer mechanism in the targets was conduction dominated for the reported range of experimental data.

  9. Runaway electrons as a diagnostic of plasma internal magnetic fluctuations

    Institute of Scientific and Technical Information of China (English)

    Zheng Yong-Zhen; Ding Xuan-Tong; Li Wen-Zhong

    2006-01-01

    The transport of runaway electrons in a high-temperature plasma is relatively easy to measure in a steady state experiment and a perturbation experiment, which provides runaway electron diffusion coefficient Dr. This diffusion coefficient is determined by internal magnetic fluctuations, so it can be interpreted in terms of a magnetic fluctuation level. The internal magnetic fluctuation level (br/BT) is estimated to be about (2-4)×-4 in the HL-1M plasma. The results presented here demonstrate the effectiveness of using runaway electron transport techniques to determine internal magnetic fluctuations. A profile of magnetic fluctuation level in the HL-1M plasma can be estimated from Dr.

  10. Development and Integration of a Data Acquisition System for SST-1 Phase-1 Plasma Diagnostics

    Institute of Scientific and Technical Information of China (English)

    Amit K SRIVASTAVA; Manika SHARMA; Imran MANSURI; Atish SHARMA; Tushar RAVAL; Subrata PRADHAN

    2012-01-01

    Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physics information) while avoiding unnecessary generation of a large volume data. SST-1 Phase-1 tokamak operation has been envisaged with data acquisition of several essential diagnostics channels. These channels demand data acquisition at a sampling rate ranging from 1 kilo samples per second (KSPS) to 1 mega samples per second (MSPS). Considering the technical characteristics and requirements of the diagnostics, a data acquisition system based on PXI and CAMAC has been developed for SST-1 plasma diagnostics. Both these data acquisition systems are scalable. Present data acquisition needs involving slow plasma diagnostics are catered by the PXI based data acquisition system. On the other hand, CAMAC data acquisition hardware meets all requirements of the SST-1 Phase-1 fast plasma diagnostics channels. A graphical user interface for both data acquisition systems (PXI and CAMAC) has been developed using LabVIEW application development software. The collected data on the local hard disk are directly streaming to the central server through a dedicated network for post-shot data analysis. This paper describes the development and integration of the data acquisition system for SST-1 Phase-1 plasma diagnostics. The integrated testing of the developed data acquisition system has been performed using SST-1 central control and diagnostics signal conditioning units. In the absence of plasma shots, the integrated testing of the data acquisition system for the initial diagnostics of SST-1 Phase-1 operation has been performed with simulated physical signals. The primary engineering objective of this integrated testing is to validate the performance of the developed data acquisition system under simulated conditions close to that of actual tokamak operation. The data

  11. Plasma Channel Diagnostic Based on Laser Centroid Oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Gonsalves, Anthony; Nakamura, Kei; Lin, Chen; Osterhoff, Jens; Shiraishi, Satomi; Schroeder, Carl; Geddes, Cameron; Toth, Csaba; Esarey, Eric; Leemans, Wim

    2010-09-09

    A technique has been developed for measuring the properties of discharge-based plasma channels by monitoring the centroid location of a laser beam exiting the channel as a function of input alignment offset between the laser and the channel. The centroid position of low-intensity (<10{sup 14}Wcm{sup -2}) laser pulses focused at the input of a hydrogen-filled capillary discharge waveguide was scanned and the exit positions recorded to determine the channel shape and depth with an accuracy of a few %. In addition, accurate alignment of the laser beam through the plasma channel can be provided by minimizing laser centroid motion at the channel exit as the channel depth is scanned either by scanning the plasma density or the discharge timing. The improvement in alignment accuracy provided by this technique will be crucial for minimizing electron beam pointing errors in laser plasma accelerators.

  12. Diagnostics of atmospheric pressure capillary DBD oxygen plasma jet

    CERN Document Server

    Roy, N C; Pramanik, B K

    2015-01-01

    Atmospheric pressure capillary dielectric barrier oxygen discharge plasma jet is developed to generate non-thermal plasma using unipolar positive pulse power supply. Both optical and electrical techniques are used to investigate the characteristics of the produced plasma as function of applied voltage and gas flow rate. Analytical results obtained from the optical emission spectroscopic data reveal the gas temperature, rotational temperature, excitation temperature and electron density. Gas temperature and rotational temperature are found to decrease with increasing oxygen flow rate but increase linearly with applied voltage. It is exposed that the electron density is boosting up with enhanced applied voltage and oxygen flow rate, while the electron excitation temperature is reducing with rising oxygen flow rate. Electrical characterization demonstrates that the discharge frequency is falling with flow rate but increasing with voltage. The produced plasma is applied preliminarily to study the inactivation yie...

  13. ECE diagnostic of high temperature ECRH heated plasmas on FTU

    Energy Technology Data Exchange (ETDEWEB)

    Zerbini, M; Buratti, P; Tudisco, O; Giruzzi, G; Bruschi, A; Cirant, S; Granucci, G; Simonetto, A; Sozzi, C; Gandini, F; Pacella, D; Fournier, K B; Finkenthal, M

    2000-01-31

    The Electron Cyclotron Emission (ECE) diagnostic on FTU tokamak is routinely performed with a Michelson interferometer with spectral range extending up to 1300 GHz. The diagnostic allowed accurate electron temperature measurements during the recent 140 Ghz Electron Cyclotron Resonance Heating (ECRH) experiments on FTU. Very accurate measurements have been performed on a wide range of electron temperatures and profile peaking. The ECE measurements have been compared with Thomson Scattering and with observations of X-ray spectra from highly stripped molybdenum ions. The suprathermal emission in these conditions has been studied.

  14. Laser-induced incandescence diagnostic for in situ monitoring of nanoparticle synthesis in an atmospheric plasma

    Science.gov (United States)

    Mitrani, James; Patel, Shane; Shneider, Mikhail; Stratton, Brent; Raitses, Yevgeny

    2014-10-01

    A DC arc discharge with a consumed graphite electrode is commonly used for synthesis of carbon nanoaparticles in a low temperature (0.1-1 eV), atmospheric pressure plasma. The formation of nanoparticles in this plasma is poorly understood; it is not clear where nanoparticles nucleate and grow in the arc discharge. Therefore, a laser-induced incandescence (LII) diagnostic for in situ monitoring of the nanoparticles' spatial distribution in the plasma is currently being constructed. The LII diagnostic involves heating the particles with a short-pulsed laser, and measuring the induced spatiotemporal incandescence profiles on longer timescales. By appropriately modeling the induced spatiotemporal incandescence profiles, one can measure particle diameters and volume fraction. LII diagnostics have been extensively used to study soot particles in flames. However, they have never been applied in a strongly coupled plasma background. Even though the spatial dimensions for soot and nanoparticles are similar, great care is needed in developing an LII diagnostic for monitoring nanoparticles in a plasma background. Therefore, we will calibrate our LII diagnostic by measuring spatiotemporal incandescence profiles of known, research grade soot and nanoparticles. This work was supported by DOE Contract DE-AC02-09CH11466.

  15. Diagnostics for plasma control on DEMO: challenges of implementation

    NARCIS (Netherlands)

    Donne, A. J. H.; Costley, A. E.; Morris, A. W.

    2012-01-01

    As a test fusion power plant, DEMO will have to demonstrate reliability and very long pulse/steady-state operation, which calls for unprecedented robustness and reliability of all diagnostic systems (also requiring adequate redundancy). But DEMO will have higher levels of neutron and gamma fluxes, a

  16. Diagnostics for plasma control on DEMO: challenges of implementation

    NARCIS (Netherlands)

    Donne, A. J. H.; Costley, A. E.; Morris, A. W.

    2012-01-01

    As a test fusion power plant, DEMO will have to demonstrate reliability and very long pulse/steady-state operation, which calls for unprecedented robustness and reliability of all diagnostic systems (also requiring adequate redundancy). But DEMO will have higher levels of neutron and gamma fluxes,

  17. Plasma cell gingivitis associated with cheilitis: A diagnostic dilemma!

    Directory of Open Access Journals (Sweden)

    Presanthila Janam

    2012-01-01

    Full Text Available Plasma cell gingivitis is a rare condition characterized by diffuse and massive infiltration of plasma cells into the sub-epithelial connective tissue. Clinically, it appears as a diffuse reddening and edematous swelling of the gingiva with a sharp demarcation along the mucogingival border. Though considered as a hypersensitive reaction to an allergen, the etiology of this bizarre condition is still not properly understood. Here, we present an interesting case of plasma cell gingivitis associated with an enlarged and fissured upper lip, which is quite a rarity. The condition was diagnosed based on clinical and histopathologic findings and treated by gingivectomy. The associated cheilitis has dramatically reduced after treatment of the gingival lesion.

  18. Diagnostic studies of ion beam formation in inductively coupled plasma

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, Jenee L. [Iowa State Univ., Ames, IA (United States)

    2015-01-01

    This dissertation describes a variety of studies focused on the plasma and the ion beam in inductively coupled plasma mass spectrometry (ICP-MS). The ability to use ICP-MS for measurements of trace elements in samples requires the analytes to be efficiently ionized. Updated ionization efficiency tables are discussed for ionization temperatures of 6500 K and 7000 K with an electron density of 1 x 1015 cm-3. These values are reflective of the current operating parameters of ICP-MS instruments. Calculations are also discussed for doubly charged (M2+) ion formation, neutral metal oxide (MO) ionization, and metal oxide (MO+) ion dissociation for similar plasma temperature values. Ionization efficiency results for neutral MO molecules in the ICP have not been reported previously.

  19. Microwave cavity diagnostics of microwave breakdown plasmas. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Eckstrom, D.J.; Williams, M.S. [SRI International, Menlo Park, CA (United States)

    1989-08-01

    We have performed microwave cavity perturbation measurements in the LLNL AIM facility using a 329-MHz cavity that allow us to examine in detail the plasma formation and decay processes for electron densities between approximately 10{sup 5} and 10{sup 7}/cm{sup 3}. We believe these to be the lowest density plasmas ever studied in microwave breakdown experiments, and as such they allow us to determine the power and energy required to produce plasmas suitable for HF radar reflection as well as the effective lifetimes of these plasmas before re-ionization is required. Analyses of these results leads to the following conclusions. (1) For microwave breakdown pulses varying from 0.6 to 2.4 {mu}s, the threshold power required to produce measurable plasmas is 30 to 12 MW/m{sup 2} at 0.01 torr, decreasing to 3.5 to 1.8 MW/m{sup 2} at 1 to 3 torr, and then increasing to 5 to 3.5 MW/m{sup 2} at 30 torr. The threshold power in each case decreases with increasing pulse length, but the required pulse energy increases with decreasing power or increasing pulse length. (2) The effective electron density decay rates are approximately 100/s for 0.1 to 1 torr, after which they increase linearly with pressure. Thus, the useful plasma lifetimes are in the range of 20 to 40 ms at the lower pressures and decrease to about 1 ms at 30 torr. These decay rates and lifetimes are comparable to those that would exist for artificially ionized regions in the upper atmosphere. (3) The collision frequencies measured at pressures of 1 torr and above correspond to electron temperatures of 800 K or less. In fact, the inferred temperatures for p > 3 torr are below room temperature. This may be due to a contribution to the measured conductivity by negative ions.

  20. Plasma diagnostics during magnetron sputtering of aluminum doped zinc oxide

    DEFF Research Database (Denmark)

    Stamate, Eugen; Crovetto, Andrea; Sanna, Simone

    2016-01-01

    Plasma parameters during magnetron sputtering of aluminum-doped zinc oxide are investigated with optical emission spectroscopy, electrostatic probes and mass spectrometry with the aim of understanding the role of negative ions of oxygen during the film growth and improving the uniformity of the f......Plasma parameters during magnetron sputtering of aluminum-doped zinc oxide are investigated with optical emission spectroscopy, electrostatic probes and mass spectrometry with the aim of understanding the role of negative ions of oxygen during the film growth and improving the uniformity...

  1. Plasma Diagnostic in laser ablation plumes for isotope separation applications

    Energy Technology Data Exchange (ETDEWEB)

    Matos, Juliana B. de [Instituto Tecnologico de Aeronautica, Sao Jose dos Campos, SP (Brazil)]. E-mail: juliana@ieav.cta.br; Rodrigues, Nicolau A.S.; Neri, Jose W.; Silveira, Carlos A.B. [Instituto de Estudos Avancados (IEAv/EFO), Sao Jose dos Campos, SP (Brazil). Div. de Fotonica

    2008-07-01

    The plasma plume produced in vacuum by ablation of copper, aluminum and tungsten samples, illuminated by copper laser pulses, was investigated. A Langmuir probe was used to study the macroscopic parameters electron number density (Ne) and electron temperature (Te). Plasma expansion velocity (Vp) was also investigated and it was studied the dependence of these parameters with the laser irradiance. Typical values are respectively N{sub e} {approx} 10{sup 8}-10{sup 9}/cm{sup 3}, T{sub e} {approx} 15 eV and Vp {approx} 10 km/s. (author)

  2. Application of coherent lidar to ion measurements in plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Hutchinson, D.P.; Richards, R.K.; Bennett, C.A.; Simpson, M.L.

    1997-03-01

    A coherent lidar system has been constructed for the measurement of alpha particles in a burning plasma. The lidar system consists of a pulsed CO{sub 2} laser transmitter and a heterodyne receiver. The receiver local oscillator is a cw, sequence-band CO{sub 2} laser operating with a 63.23 GHz offset from the transmitter.

  3. Overview of C-2 field-reversed configuration experiment plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Gota, H., E-mail: hgota@trialphaenergy.com; Thompson, M. C.; Tuszewski, M.; Binderbauer, M. W. [Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States)

    2014-11-15

    A comprehensive diagnostic suite for field-reversed configuration (FRC) plasmas has been developed and installed on the C-2 device at Tri Alpha Energy to investigate the dynamics of FRC formation as well as to understand key FRC physics properties, e.g., confinement and stability, throughout a discharge. C-2 is a unique, large compact-toroid merging device that produces FRC plasmas partially sustained for up to ∼5 ms by neutral-beam (NB) injection and end-on plasma-guns for stability control. Fundamental C-2 FRC properties are diagnosed by magnetics, interferometry, Thomson scattering, spectroscopy, bolometry, reflectometry, and NB-related fast-ion/neutral diagnostics. These diagnostics (totaling >50 systems) are essential to support the primary goal of developing a deep understanding of NB-driven FRCs.

  4. Overview of C-2 field-reversed configuration experiment plasma diagnostics.

    Science.gov (United States)

    Gota, H; Thompson, M C; Tuszewski, M; Binderbauer, M W

    2014-11-01

    A comprehensive diagnostic suite for field-reversed configuration (FRC) plasmas has been developed and installed on the C-2 device at Tri Alpha Energy to investigate the dynamics of FRC formation as well as to understand key FRC physics properties, e.g., confinement and stability, throughout a discharge. C-2 is a unique, large compact-toroid merging device that produces FRC plasmas partially sustained for up to ∼5 ms by neutral-beam (NB) injection and end-on plasma-guns for stability control. Fundamental C-2 FRC properties are diagnosed by magnetics, interferometry, Thomson scattering, spectroscopy, bolometry, reflectometry, and NB-related fast-ion/neutral diagnostics. These diagnostics (totaling >50 systems) are essential to support the primary goal of developing a deep understanding of NB-driven FRCs.

  5. Perspective: The physics, diagnostics, and applications of atmospheric pressure low temperature plasma sources used in plasma medicine

    Science.gov (United States)

    Laroussi, M.; Lu, X.; Keidar, M.

    2017-07-01

    Low temperature plasmas have been used in various plasma processing applications for several decades. But it is only in the last thirty years or so that sources generating such plasmas at atmospheric pressure in reliable and stable ways have become more prevalent. First, in the late 1980s, the dielectric barrier discharge was used to generate relatively large volume diffuse plasmas at atmospheric pressure. Then, in the early 2000s, plasma jets that can launch cold plasma plumes in ambient air were developed. Extensive experimental and modeling work was carried out on both methods and much of the physics governing such sources was elucidated. Starting in the mid-1990s, low temperature plasma discharges have been used as sources of chemically reactive species that can be transported to interact with biological media, cells, and tissues and induce impactful biological effects. However, many of the biochemical pathways whereby plasma affects cells remain not well understood. This situation is changing rather quickly because the field, known today as "plasma medicine," has experienced exponential growth in the last few years thanks to a global research community that engaged in fundamental and applied research involving the use of cold plasma for the inactivation of bacteria, dental applications, wound healing, and the destruction of cancer cells/tumors. In this perspective, the authors first review the physics as well as the diagnostics of the principal plasma sources used in plasma medicine. Then, brief descriptions of their biomedical applications are presented. To conclude, the authors' personal assessment of the present status and future outlook of the field is given.

  6. Laser Diagnostic Method for Plasma Sheath Potential Mapping

    Science.gov (United States)

    Walsh, Sean P.

    Electric propulsion systems are gaining popularity in the aerospace field as a viable option for long term positioning and thrusting applications. In particular, Hall thrusters have shown promise as the primary propulsion engine for space probes during interplanetary journeys. However, the interaction between propellant xenon ions and the ceramic channel wall continues to remain a complex issue. The most significant source of power loss in Hall thrusters is due to electron and ion currents through the sheath to the channel wall. A sheath is a region of high electric field that separates a plasma from a wall or surface in contact. Plasma electrons with enough energy to penetrate the sheath may result emission of a secondary electron from the wall. With significant secondary electron emission (SEE), the sheath voltage is reduced and so too is the electron retarding electric field. Therefore, a lower sheath voltage further increases the particle loss to the wall of a Hall thruster and leads to plasma cooling and lower efficiency. To further understand sheath dynamics, laser-induced fluorescence is employed to provide a non-invasive, in situ, and spatially resolved technique for measuring xenon ion velocity. By scanning the laser wavelength over an electronic transition of singly ionized xenon and collecting the resulting fluorescence, one can determine the ion velocity from the Doppler shifted absorption. Knowing the velocity at multiple points in the sheath, it can be converted to a relative electric potential profile which can reveal a lot about the plasma-wall interaction and the severity of SEE. The challenge of adequately measuring sheath potential profiles is optimizing the experiment to maximize the signal-to-noise ratio. A strong signal with low noise, enables high resolution measurements and increases the depth of measurement in the sheath, where the signal strength is lowest. Many improvements were made to reduce the background luminosity, increase the

  7. In situ electromagnetic field diagnostics with an electron plasma in a Penning-Malmberg trap

    Science.gov (United States)

    Amole, C.; Ashkezari, M. D.; Baquero-Ruiz, M.; Bertsche, W.; Butler, E.; Capra, A.; Cesar, C. L.; Charlton, M.; Deller, A.; Evetts, N.; Eriksson, S.; Fajans, J.; Friesen, T.; Fujiwara, M. C.; Gill, D. R.; Gutierrez, A.; Hangst, J. S.; Hardy, W. N.; Hayden, M. E.; Isaac, C. A.; Jonsell, S.; Kurchaninov, L.; Little, A.; Madsen, N.; McKenna, J. T. K.; Menary, S.; Napoli, S. C.; Olchanski, K.; Olin, A.; Pusa, P.; Rasmussen, C. Ø.; Robicheaux, F.; Sarid, E.; Silveira, D. M.; So, C.; Stracka, S.; Tharp, T.; Thompson, R. I.; van der Werf, D. P.; Wurtele, J. S.

    2014-01-01

    We demonstrate a novel detection method for the cyclotron resonance frequency of an electron plasma in a Penning-Malmberg trap. With this technique, the electron plasma is used as an in situ diagnostic tool for the measurement of the static magnetic field and the microwave electric field in the trap. The cyclotron motion of the electron plasma is excited by microwave radiation and the temperature change of the plasma is measured non-destructively by monitoring the plasma's quadrupole mode frequency. The spatially resolved microwave electric field strength can be inferred from the plasma temperature change and the magnetic field is found through the cyclotron resonance frequency. These measurements were used extensively in the recently reported demonstration of resonant quantum interactions with antihydrogen.

  8. Laser Thomson scattering diagnostics of non-equilibrium high pressure plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Muraoka, K.; Uchino, K.; Bowden, M.D.; Noguchi, Y. [Kyushu Univ., Fukuoka (Japan). Interdisciplinary Graduate School of Engineering Sciences

    2001-07-01

    For various applications of non-equilibrium high pressure plasmas, knowledge of electron properties, such as electron density, electron temperature and/or electron energy distribution function (eedf), is prerequisite for any rational approach to understanding physical and chemical processes occurring in the plasmas. For this purpose, laser Thomson scattering has been successfully applied for the first time to measure the electron properties in plasmas for excimer laser pumping and in microdischarges. Although this diagnostic technique is well established for measurements in high temperature plasmas, its applications to these glow discharge plasmas have had various inherent difficulties, such as a presence of high density neutral particles (>10{sup 21} m{sup -3}) in the excimer laser pumping discharges and an extremely small plasma size (<0.1 mm) and the presence of nearby walls for microdischarges. These difficulties have been overcome and clear signals have been obtained. The measured results are presented and their implications in the respective discharge phenomena are discussed.

  9. In situ electromagnetic field diagnostics with an electron plasma in a Penning-Malmberg trap

    CERN Document Server

    Amole, C; Baquero-Ruiz, M.; Bertsche, W.; Butler, E.; Capra, A.; Cesar, C.L.; Charlton, M.; Deller, A.; Evetts, N.; Eriksson, S.; Fajans, J.; Friesen, T.; Fujiwara, M.C.; Gill, D.R.; Gutierrez, A.; Hangst, J.S.; Hardy, W.N.; Hayden, M.E.; Isaac, C.A.; Jonsell, S.; Kurchaninov, L.; Little, A.; Madsen, N.; McKenna, J.T.K.; Menary, S.; Napoli, S.C.; Olchanski, K.; Olin, A.; Pusa, P.; Rasmussen, C.; Robicheaux, F.; Sarid, E.; Silveira, D.M.; So, C.; Stracka, S.; Tharp, T.; Thompson, R.I.; van der Werf, D.P.; Wurtele, J.S.

    2014-01-01

    We demonstrate a novel detection method for the cyclotron resonance frequency of an electron plasma in a Penning-Malmberg trap. With this technique, the electron plasma is used as an in situ diagnostic tool for measurement of the static magnetic field and the microwave electric field in the trap. The cyclotron motion of the electron plasma is excited by microwave radiation and the temperature change of the plasma is measured non-destructively by monitoring the plasma's quadrupole mode frequency. The spatially-resolved microwave electric field strength can be inferred from the plasma temperature change and the magnetic field is found through the cyclotron resonance frequency. These measurements were used extensively in the recently reported demonstration of resonant quantum interactions with antihydrogen.

  10. Diagnostic potential of plasma carboxymethyllysine and carboxyethyllysine in multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Weinstock-Guttmann Bianca

    2010-10-01

    Full Text Available Abstract Background This study compared the level of advanced glycation end products (AGEs, N-(Carboxymethyllysine (CML and N-(Carboxyethyllysine (CEL, in patients with multiple sclerosis (MS and healthy controls (HCs, correlating these markers with clinical indicators of MS disease severity. Methods CML and CEL plasma levels were analyzed in 99 MS patients and 43 HCs by tandem mass spectrometry (LC/MS/MS. Patients were stratified based on drug modifying therapies (DMTs including interferon beta, glatiramer acetate and natalizumab. Results The level of plasma CEL, but not CML, was significantly higher in DMT-naïve MS patients when compared to HCs (P Conclusion Our results suggest that AGEs in general and CEL in particular could be useful biomarkers in MS clinical practice. Longitudinal studies are warranted to determine any causal relationship between changes in plasma level of AGEs and MS disease pathology. These studies will pave the way for use of AGE inhibitors and AGE-breaking agents as new therapeutic modalities in MS.

  11. Plasma tests of diagnostic mirrors for ITER purposes

    Energy Technology Data Exchange (ETDEWEB)

    Vukolov, K.Yu., E-mail: vukolov@nfi.kiae.ru [NRC “Kurchatov Institute”, Kurchatov sq.1, 123182 Moscow (Russian Federation); Mukhammedzyanov, T.R.; Andreenko, E.N. [NRC “Kurchatov Institute”, Kurchatov sq.1, 123182 Moscow (Russian Federation); Arkhipov, I.I. [A.N. Frumkin Institute of Physical Chemistry and Electrochemistry, RAS, Leninsky pr. 31, 119991 Moscow (Russian Federation); Orlovskiy, I.I.; Tobengauz, A.M.; Vukolov, D.K. [NRC “Kurchatov Institute”, Kurchatov sq.1, 123182 Moscow (Russian Federation)

    2013-10-15

    Highlights: •Prototype of ITER H-alpha endoscope with 1 mm pupil is tested in T-10 tokamak. •Three molybdenum mirrors either preserved their reflectivity or were locally damaged. •First mirror assembly with 4 mm pupil was tested in ITER-like conditions. •Mirrors preserved their reflectivity after 40 h test treated as 400 pulses. •Small entrance pupil is vital for lifetime of the first mirror. -- Abstract: One of the main problems of ITER optical diagnostics is the degradation of collecting mirrors by erosion or impurity deposition. It is suggested to reduce the degradation by small entrance pupil in optical system. The prototype of endoscope optical system for H-alpha ITER diagnostics is under testing in T-10 tokamak. It has entrance pupil of 1 mm diameter. Three molybdenum mirrors were tested between 1 and 3 years. In spite of local degradation or surface damages appeared after 2 years of operation, the diagnostics remained functional. In parallel, the first mirror assembly (FMA) with 4 mm pupil was tested in a magnetron sputtering installation. Deuterium pressure was 0.7 Pa during magnetron discharge with 1 A current. Estimated flux of aluminum and carbon atoms was about 10{sup 14} at cm{sup −2} s{sup −1} on the FMA entrance pupil. As a result, FMA molybdenum mirrors preserved their reflectivity after 40 h of exposure which can be considered as 400 ITER pulses. Thereby small entrance pupil appears as a good solution for first mirror protection.

  12. Nonlinear frequency shift in Raman backscattering and its implications for plasma diagnostics

    Science.gov (United States)

    Kaganovich, D.; Hafizi, B.; Palastro, J. P.; Ting, A.; Helle, M. H.; Chen, Y.-H.; Jones, T. G.; Gordon, D. F.

    2016-12-01

    Raman backscattered radiation of intense laser pulses in plasmas is investigated for a wide range of intensities relevant to laser wakefield acceleration. The weakly nonlinear dispersion relation for Raman backscattering predicts an intensity and density dependent frequency shift that is opposite to that suggested by a simple relativistic consideration. This observation has been benchmarked against experimental results, providing a novel diagnostic for laser-plasma interactions.

  13. Nonlinear Frequency Shift in Raman Backscattering and its Implications for Plasma Diagnostics

    CERN Document Server

    Kaganovich, D; Palastro, J P; Ting, A; Helle, M H; Chen, Y -H; Jones, T G; Gordon, D F

    2016-01-01

    Raman backscattered radiation of intense laser pulses in plasma is investigated for a wide range of intensities relevant to laser wakefield acceleration. The weakly nonlinear dispersion relation for Raman backscattering predicts an intensity and density dependent frequency shift that is opposite to that suggested by a simple relativistic consideration. This observation has been benchmarked against experimental results, providing a novel diagnostic for laser-plasma interactions.

  14. Plasma diagnostic techniques in thermal-barrier tandem-mirror fusion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Silver, E.H.; Clauser, J.F.; Carter, M.R.; Failor, B.H.; Foote, J.H.; Hornady, R.S.; James, R.A.; Lasnier, C.J.; Perkins, D.E.

    1986-08-29

    We review two classes of plasma diagnostic techniques used in thermal-barrier tandem-mirror fusion experiments. The emphasis of the first class is to study mirror-trapped electrons at the thermal-barrier location. The focus of the second class is to measure the spatial and temporal behavior of the plasma space potential at various axial locations. The design and operation of the instruments in these two categories are discussed and data that are representative of their performance is presented.

  15. Diagnostics of Atmospheric Pressure Surface Discharge Plasmas in Argon

    Institute of Scientific and Technical Information of China (English)

    张锐; 詹如娟; 温晓辉

    2003-01-01

    Atmospheric pressure surface discharge is shown to have great prospects for a number of industrial applications.To acquire better results in application fields and considering that the study of the basic parameters including electron temperature and electron density is desirable,we develop an equivalent circuit model and the diagnostic techniques based on optical emission spectroscopy and electrical measurement in our laboratory.The electron temperature has been determined to be about 0.7eV by a Fermi-Dirac model.The electron density has been calculated to be near 1010 cm-3 from a time resolved electrical measurement(Ohmic heating method).

  16. Nonintrusive microwave diagnostics of collisional plasmas in Hall thrusters and dielectric barrier discharges

    Science.gov (United States)

    Stults, Joshua

    This research presents a numerical framework for diagnosing electron properties in collisional plasmas. Microwave diagnostics achieved a significant level of development during the middle part of the last century due to work in nuclear weapons and fusion plasma research. With the growing use of plasma-based devices in fields as diverse as space propulsion, materials processing and fluid flow control, there is a need for improved, flexible diagnostic techniques suitable for use under the practical constraints imposed by plasma fields generated in a wide variety of aerospace devices. Much of the current diagnostic methodology in the engineering literature is based on analytical diagnostic, or forward, models. The Appleton-Hartree formula is an oft-used analytical relation for the refractive index of a cold, collisional plasma. Most of the assumptions underlying the model are applicable to diagnostics for plasma fields such as those found in Hall Thrusters and dielectric barrier discharge (DBD) plasma actuators. Among the assumptions is uniform material properties, this assumption is relaxed in the present research by introducing a flexible, numerical model of diagnostic wave propagation that can capture the effects of spatial gradients in the plasma state. The numerical approach is chosen for its flexibility in handling future extensions such as multiple spatial dimensions to account for scattering effects when the spatial extent of the plasma is small relative to the probing beam's width, and velocity dependent collision frequency for situations where the constant collision frequency assumption is not justified. The numerical wave propagation model (forward model) is incorporated into a general tomographic reconstruction framework that enables the combination of multiple interferometry measurements. The combined measurements provide a quantitative picture of the spatial variation in the plasma properties. The benefit of combining multiple measurements in a coherent

  17. Simulated plasma facing component measurements for an in situ surface diagnostic on Alcator C-Moda)

    Science.gov (United States)

    Hartwig, Z. S.; Whyte, D. G.

    2010-10-01

    The ideal in situ plasma facing component (PFC) diagnostic for magnetic fusion devices would perform surface element and isotope composition measurements on a shot-to-shot (˜10 min) time scale with ˜1 μm depth and ˜1 cm spatial resolution over large areas of PFCs. To this end, the experimental adaptation of the customary laboratory surface diagnostic—nuclear scattering of MeV ions—to the Alcator C-Mod tokamak is being guided by ACRONYM, a Geant4 synthetic diagnostic. The diagnostic technique and ACRONYM are described, and synthetic measurements of film thickness for boron-coated PFCs are presented.

  18. Electron kinetic effects on optical diagnostics in fusion plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Mirnov, V. V.; Den Hartog, D. J.; Duff, J.; Parke, E. [University of Wisconsin-Madison and the Center for Magnetic Self-Organization in Laboratory and Astrophysical Plasmas, Madison, Wisconsin (United States); Brower, D. L., E-mail: vvmirnov@wisc.edu; Ding, W. X. [University of California Los Angeles, Los Angeles, California (United States)

    2014-08-21

    At anticipated high electron temperatures in ITER, the effects of electron thermal motion on Thomson scattering (TS), toroidal interferometer/polarimeter (TIP) and poloidal polarimeter (PoPola) diagnostics will be significant and must be accurately treated. We calculate electron thermal corrections to the interferometric phase and polarization state of an EM wave propagating along tangential and poloidal chords (Faraday and Cotton-Mouton polarimetry) and perform analysis of the degree of polarization for incoherent TS. The precision of the previous lowest order linear in τ = T{sub e}/m{sub e}c{sup 2} model may be insufficient; we present a more precise model with τ{sup 2}-order corrections to satisfy the high accuracy required for ITER TIP and PoPola diagnostics. The linear model is extended from Maxwellian to a more general class of anisotropic electron distributions that allows us to take into account distortions caused by equilibrium current, ECRH and RF current drive effects. The classical problem of degree of polarization of incoherent Thomson scattered radiation is solved analytically exactly without any approximations for the full range of incident polarizations, scattering angles, and electron thermal motion from non-relativistic to ultra-relativistic. The results are discussed in the context of the possible use of the polarization properties of Thomson scattered light as a method of T{sup e} measurement relevant to ITER operational scenarios.

  19. Laser Diagnostics Study of Plasma Assisted Combustion for Scramjet Applications

    Science.gov (United States)

    2011-12-01

    treatment of the fuel or reactants into hydrogen rich syngas prior to thermal oxidation [11-12], enhanced ignition of hydrocarbon fuels [9,13-14...dramatically, and a significant rise of OH in the post combustion gas region is evident. It is 532 nm Power Supply N d: YA G L as er Dye Laser...plasma, ne~1014-1015 cm-3). The power supply is a 2 kW magnetron (2.45 GHz), although no more than 40 W seems to be required for most test conditions due

  20. Diagnostic value of plasma aldosterone/potassium ratio in hypoaldosteronism.

    Science.gov (United States)

    Shiah, C J; Wu, K D; Tsai, D M; Liao, S T; Siauw, C P; Lee, L S

    1995-05-01

    The diagnosis of hypoaldosteronism usually depends upon a combination of abnormal clinical and laboratory findings. The most common abnormality in hypoaldosteronism is hyperkalemia, which may be combined with sodium depletion. In the present study, 5 of 16 patients diagnosed with isolated hypoaldosteronism (IHA) had sodium depletion due to renal salt wasting, and four patients had normokalemia. Of these 16 IHA patients, 70% had subnormal baseline and stimulated plasma renin activity (PRA). Six patients diagnosed with type I pseudohypoaldosteronism (PHA) had normal or high PRA and plasma aldosterone concentrations (PAC). In 11 control subjects, supine PAC correlated positively with serum potassium (SK), and PAC stimulated by furosemide and ambulation correlated with the 24-hour urinary potassium excretion (UK). However, these correlations were not found in IHA and PHA patients. The ratio of UK/UNa+K and UNa/UK correlated with the stimulated PAC when the IHA and control subjects were taken as a whole. However, these electrolyte excretion parameters bore no relationship to the supine PAC. The stimulated PAC/SK ratio was used to discriminate the three groups; all IHA patients had a ratio below 3. The results indicate that stimulated PAC reflects the bioactivity of aldosterone on the collecting tubule, and the stimulated PAC/SK ratio is useful for the diagnosis of hypoaldosteronism and pseudohypoaldosteronism.

  1. Dust dynamics and diagnostic applications in quasi-neutral plasmas and magnetic fusion

    Science.gov (United States)

    Wang, Zhehui; Ticos, Catalin M.; Si, Jiahe; Delzanno, Gian Luca; Lapenta, Gianni; Wurden, Glen

    2007-11-01

    Little is known about dust dynamics in highly ionized quasi-neutral plasmas with ca. 1.0 e+20 per cubic meter density and ion temperature at a few eV and above, including in magnetic fusion. For example, dust motion in fusion, better known as UFO's, has been observed since 1980's but not explained. Solid understanding of dust dynamics is also important to International Thermonuclear Experimental Reactor (ITER) because of concerns about safety and dust contamination of fusion core. Compared with well studied strongly-coupled dusty plasma regime, new physics may arise in the higher density quasi-neutral plasma regime because of at least four orders of magnitude higher density and two orders of magnitude hotter ion temperature. Our recent laboratory experiments showed that plasma-flow drag force dominates over other forces in a quasi-neutral flowing plasma. In contrast, delicate balance among different forces in dusty plasma has led to many unique phenomena, in particular, the formation of dust crystal. Based on our experiments, we argue that 1) dust crystal will not form in the highly ionized plasmas with flows; 2) the UFO's are moving dust dragged by plasma flows; 3) dust can be used to measure plasma flow. Two diagnostic applications using dust for laboratory quasi-neutral plasmas and magnetic fusion will also be presented.

  2. Plasma plume diagnostics of low power stationary plasma thruster (SPT-20M8) with collisional radiative model

    Science.gov (United States)

    Uttamsing Rajput, Rajendrasing; Alona, Khaustova; Loyan, Andriy V.

    2017-03-01

    Electric propulsion offers higher specific impulse compared to the chemical propulsion systems. It reduces the overall propellant mass and enables high operational lifetimes. Scientific Technological Center of Space Power and Energy (STC SPE), KhAI is involved in designing, manufacturing and testing of stationary plasma thrusters (SPT). Efforts are made to perform plasma diagnostics with corona and collisional radiative models (C-R model), as expected corona model falls short below 4 eV because of the heavy particle collisions elimination, whereas the C-R model's applicability is confirmed. Several tests are performed to analyze the electron temperature at various operational parameters of thruster like discharge voltage and mass flow rate. SPT-20M8 far and near-field plumes diagnostics are performed. Feasibility of C-R model by comparing its result to optical emission spectroscopy (OES) to investigate the electron temperature is validated with the probe measurements within the 10% of discrepancy.

  3. FAR-TECH's Nanoparticle Plasma Jet System and its Application to Disruptions, Deep Fueling, and Diagnostics

    Science.gov (United States)

    Thompson, J. R.; Bogatu, I. N.; Galkin, S. A.; Kim, J. S.

    2012-10-01

    Hyper-velocity plasma jets have potential applications in tokamaks for disruption mitigation, deep fueling and diagnostics. Pulsed power based solid-state sources and plasma accelerators offer advantages of rapid response and mass delivery at high velocities. Fast response is critical for some disruption mitigation scenario needs, while high velocity is especially important for penetration into tokamak plasma and its confining magnetic field, as in the case of deep fueling. FAR-TECH is developing the capability of producing large-mass hyper-velocity plasma jets. The prototype solid-state source has produced: 1) >8.4 mg of H2 gas only, and 2) >25 mg of H2 and >180 mg of C60 in a H2/C60 gas mixture. Using a coaxial plasma gun coupled to the source, we have successfully demonstrated the acceleration of composite H/C60 plasma jets, with momentum as high as 0.6 g.km/s, and containing an estimated C60 mass of ˜75 mg. We present the status of FAR-TECH's nanoparticle plasma jet system and discuss its application to disruptions, deep fueling, and diagnostics. A new TiH2/C60 solid-state source capable of generating significantly higher quantities of H2 and C60 in <0.5 ms will be discussed.

  4. Plasma Diagnostics of the Interstellar Medium with Radio Astronomy

    CERN Document Server

    Haverkorn, Marijke

    2013-01-01

    We discuss the degree to which radio propagation measurements diagnose conditions in the ionized gas of the interstellar medium (ISM). The "signal generators" of the radio waves of interest are extragalactic radio sources (quasars and radio galaxies), as well as Galactic sources, primarily pulsars. The polarized synchrotron radiation of the Galactic non-thermal radiation also serves to probe the ISM, including space between the emitting regions and the solar system. Radio propagation measurements provide unique information on turbulence in the ISM as well as the mean plasma properties such as density and magnetic field strength. Radio propagation observations can provide input to the major contemporary questions on the nature of ISM turbulence, such as its dissipation mechanisms and the processes responsible for generating the turbulence on large spatial scales. Measurements of the large scale Galactic magnetic field via Faraday rotation provide unique observational input to theories of the generation of the ...

  5. Basis set expansion for inverse problems in plasma diagnostic analysis

    Science.gov (United States)

    Jones, B.; Ruiz, C. L.

    2013-07-01

    A basis set expansion method [V. Dribinski, A. Ossadtchi, V. A. Mandelshtam, and H. Reisler, Rev. Sci. Instrum. 73, 2634 (2002)], 10.1063/1.1482156 is applied to recover physical information about plasma radiation sources from instrument data, which has been forward transformed due to the nature of the measurement technique. This method provides a general approach for inverse problems, and we discuss two specific examples relevant to diagnosing fast z pinches on the 20-25 MA Z machine [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats, J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K. W. Struve, W. A. Stygar, L. K. Warne, J. R. Woodworth, C. W. Mendel, K. R. Prestwich, R. W. Shoup, D. L. Johnson, J. P. Corley, K. C. Hodge, T. C. Wagoner, and P. E. Wakeland, in Proceedings of the Pulsed Power Plasma Sciences Conference (IEEE, 2007), p. 979]. First, Abel inversion of time-gated, self-emission x-ray images from a wire array implosion is studied. Second, we present an approach for unfolding neutron time-of-flight measurements from a deuterium gas puff z pinch to recover information about emission time history and energy distribution. Through these examples, we discuss how noise in the measured data limits the practical resolution of the inversion, and how the method handles discontinuities in the source function and artifacts in the projected image. We add to the method a propagation of errors calculation for estimating uncertainties in the inverted solution.

  6. Basis set expansion for inverse problems in plasma diagnostic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jones, B.; Ruiz, C. L. [Sandia National Laboratories, PO Box 5800, Albuquerque, New Mexico 87185 (United States)

    2013-07-15

    A basis set expansion method [V. Dribinski, A. Ossadtchi, V. A. Mandelshtam, and H. Reisler, Rev. Sci. Instrum. 73, 2634 (2002)] is applied to recover physical information about plasma radiation sources from instrument data, which has been forward transformed due to the nature of the measurement technique. This method provides a general approach for inverse problems, and we discuss two specific examples relevant to diagnosing fast z pinches on the 20–25 MA Z machine [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats, J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K. W. Struve, W. A. Stygar, L. K. Warne, J. R. Woodworth, C. W. Mendel, K. R. Prestwich, R. W. Shoup, D. L. Johnson, J. P. Corley, K. C. Hodge, T. C. Wagoner, and P. E. Wakeland, in Proceedings of the Pulsed Power Plasma Sciences Conference (IEEE, 2007), p. 979]. First, Abel inversion of time-gated, self-emission x-ray images from a wire array implosion is studied. Second, we present an approach for unfolding neutron time-of-flight measurements from a deuterium gas puff z pinch to recover information about emission time history and energy distribution. Through these examples, we discuss how noise in the measured data limits the practical resolution of the inversion, and how the method handles discontinuities in the source function and artifacts in the projected image. We add to the method a propagation of errors calculation for estimating uncertainties in the inverted solution.

  7. [Plasma cholesterol determination in birds--a diagnostic tool for detection of organophosphate and carbamate intoxication].

    Science.gov (United States)

    Kiesau, B; Kummerfeld, N

    1998-07-01

    An investigation was done on the clinical usefulness of the dry chemistry analyzer Vitros DT 60 II for determination of avian plasma cholinesterase. The analytical reliability of the method, evaluated by precision and accuracy, proved to be high for plasma of numerous pet and wild birds. Values of normal plasma-cholinesterase activity were established for different psittacine and European wild birds. Significant differences in physiologic plasma-cholinesterase activity were noted between closely related species as well as between juvenile and adult birds. These findings emphasize the necessity to use control values of the same species and age group for comparison. Dry chemistry plasma-cholinesterase determination can be used as a diagnostic tool for detection of organophosphate and carbamate poisonings in the majority of investigated birds.

  8. VUV diagnostic of electron impact processes in low temperature molecular hydrogen plasma

    CERN Document Server

    Komppula, J

    2015-01-01

    Novel methods for diagnostics of molecular hydrogen plasma processes, such as ionization, production of high vibrational levels, dissociation of molecules via excitation to singlet and triplet states and production of metastable states, are presented for molecular hydrogen plasmas in corona equilibrium. The methods are based on comparison of rate coefficients of plasma processes and optical emission spectroscopy of lowest singlet and triplet transitions, i.e. Lyman-band ($B^1\\Sigma^+_u \\rightarrow X^1\\Sigma^+_g$) and molecular continuum ($a^3\\Sigma^+_g \\rightarrow b^3\\Sigma^+_u$), of the hydrogen molecule in VUV wavelength range. Comparison of rate coefficients of spin-allowed and/or spin-forbidden excitations reduces the uncertainty caused by the non-equilibrium distributions of electron energy and molecular vibrational level, which are typically known poorly in plasma sources. The described methods are applied to estimate the rates of various plasma processes in a filament arc discharge.

  9. Microwave Diagnostics for Studies of Electromagnetic Scattering by Fluorescent Lamp Plasma

    Institute of Scientific and Technical Information of China (English)

    Xiang HE; Jian-ping CHEN; Ying WU; Yu-dong CHEN; Xiao-jun ZENC; Hai-chao QIN; Xiao-wu NI

    2010-01-01

    This gaper reports a related microwave diagnostic method that measures both the electron number density and the electron-neutral collision frequency,which are crucial to understand the behavior of microwave traveling in plasma.Arrays of standard commerci fluorescent lamp placed directly against each other in two rows are used to peoduce a plasma layer.Attenuations of microwave by plasma layer are studied experimentally in the frequencies of 1~8 GHz using a synthesized signal generator and a spectrum analyzer.Two wave-polarizations are under investigation:electric field of the wave is either parallel(E-wave)or perprndicular(H-wave)to the fluorescent lamp axis.The electron number density and the electron-neutral collision frequensy of fluorescent lamp plasma are obtained by microwave diagnstics,for the purpose of analyzing microwave scattering characteristics by plasma.

  10. Backreflection diagnostics for ultra-intense laser plasma experiments based on frequency resolved optical gating

    Science.gov (United States)

    Wagner, F.; Hornung, J.; Schmidt, C.; Eckhardt, M.; Roth, M.; Stöhlker, T.; Bagnoud, V.

    2017-02-01

    We report on the development and implementation of a time resolved backscatter diagnostics for high power laser plasma experiments at the petawatt-class laser facility PHELIX. Pulses that are backscattered or reflected from overcritical plasmas are characterized spectrally and temporally resolved using a specially designed second harmonic generation frequency resolved optical gating system. The diagnostics meets the requirements made by typical experiments, i.e., a spectral bandwidth of more than 30 nm with sub-nanometer resolution and a temporal window of 10 ps with 50 fs temporal resolution. The diagnostics is permanently installed at the PHELIX target area and can be used to study effects such as laser-hole boring or relativistic self-phase-modulation which are important features of laser-driven particle acceleration experiments.

  11. SXR-XUV Diagnostics for Edge and Core of Magnetically Confined Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Stutman, Dan [Johns Hopkins University

    2014-09-10

    The present report summarizes the results obtained during a one-year extension of DoE grant “SXR-XUV Diagnostics for Edge and Core of Magnetically Confined Plasmas”, at Johns Hopkins University, aimed at completing the development of a new type of magnetic fusion plasma diagnostic, the XUV Transmission Grating Imaging Radiometer (TGIR). The TGIR enables simultaneous spatially and spectrally resolved measurements of the XUV/VUV radiated power from impurities in fusion plasmas, with high speed. The instrument was successfully developed and qualified in the laboratory and in experiments on a tokamak. Its future applications will be diagnostic of the impurity content and transport in the divertor and edge of advanced magnetic fusion experiments, such as NSTX Upgrade.

  12. High-efficiency fast scintillators for "optical" soft x-ray arrays for laboratory plasma diagnostics.

    Science.gov (United States)

    Delgado-Aparicio, L F; Stutman, D; Tritz, K; Vero, R; Finkenthal, M; Suliman, G; Kaita, R; Majeski, R; Stratton, B; Roquemore, L; Tarrio, C

    2007-08-20

    Scintillator-based "optical" soft x-ray (OSXR) arrays have been investigated as a replacement for the conventional silicon (Si)-based diode arrays used for imaging, tomographic reconstruction, magnetohydrodynamics, transport, and turbulence studies in magnetically confined fusion plasma research. An experimental survey among several scintillator candidates was performed, measuring the relative and absolute conversion efficiencies of soft x rays to visible light. Further investigations took into account glass and fiber-optic face-plates (FOPs) as substrates, and a thin aluminum foil (150 nm) to reflect the visible light emitted by the scintillator back to the optical detector. Columnar (crystal growth) thallium-doped cesium iodide (CsI:Tl) deposited on an FOP, was found to be the best candidate for the previously mentioned plasma diagnostics. Its luminescence decay time of the order of approximately 1-10 micros is thus suitable for the 10 micros time resolution required for the development of scintillator-based SXR plasma diagnostics. A prototype eight channel OSXR array using CsI:Tl was designed, built, and compared to an absolute extreme ultraviolet diode counterpart: its operation on the National Spherical Torus Experiment showed a lower level of induced noise relative to the Si-based diode arrays, especially during neutral beam injection heated plasma discharges. The OSXR concept can also be implemented in less harsh environments for basic spectroscopic laboratory plasma diagnostics.

  13. Diagnostics and results from coaxial plasma gun development for the PLX- α project

    Science.gov (United States)

    Case, A.; Brockington, S.; Cruz, E.; Witherspoon, F. D.

    2016-10-01

    We present results from the diagnostics used during development of the contoured gap coaxial plasma guns for the PLX- α project at LANL. Plasma-jet diagnostics include fast photodiodes for velocimetry, a ballistic pendulum for total plasmoid momentum, and interferometry for line integrated density. Deflectometry will be used for line integrated perpendicular density gradients. Time-resolved high-resolution spectroscopy using a novel detector and time-integrated survey spectroscopy are used for measurements of velocity and temperature, as well as impurities. We will also use a Faraday cup for density, fast imaging for plume geometry, and time-integrated imaging for overall light emission. Experimental results are compared to the desired target parameters for the plasma jets (up to n 2 ×1016cm-3 , v 50km / s , mass 5gm , radius = 4cm , and length 10cm). This work supported by the ARPA-E ALPHA Program.

  14. Synthetic plasma edge diagnostics for EMC3-EIRENE, highlighted for Wendelstein 7-X

    Science.gov (United States)

    Frerichs, H.; Effenberg, F.; Schmitz, O.; Biedermann, C.; Feng, Y.; Jakubowski, M.; König, R.; Krychowiak, M.; Lore, J.; Niemann, H.; Pedersen, T. S.; Stephey, L.; Wurden, G. A.

    2016-11-01

    Interpretation of spectroscopic measurements in the edge region of high-temperature plasmas can be a challenge since line of sight integration effects make direct interpretation in terms of quantitative, local emission strengths often impossible. The EMC3-EIRENE code—a 3D fluid edge plasma and kinetic neutral gas transport code—is a suitable tool for full 3D reconstruction of such signals. A versatile synthetic diagnostic module has been developed recently which allows the realistic 3D setup of various plasma edge diagnostics to be captured. We highlight these capabilities with two examples for Wendelstein 7-X (W7-X): a visible camera for the analysis of recycling, and a coherent-imaging system for velocity measurements.

  15. Overview of the electric propulsion plasma diagnostics suite for the VASIMR VX-200 testbed

    Science.gov (United States)

    Olsen, Christopher; Longmier, Benjamin; Ballenger, Maxwell; Squire, Jared; Glover, Tim; Carter, Mark; Bering, Edgar; Giambusso, Matthew

    2012-10-01

    Descriptions of the various plasma diagnostics and data analysis methods are given for instruments used in high power (> 100 kW) electric propulsion testing. These include planar Langmuir probes, an articulating retarding potential analyzer, a double Langmuir probe, a multi-axis magnetometer, a high frequency electric field probe, microwave interferometer, and momentum flux targets. These diagnostics have been used to measure the efficiencies of the thruster, plasma source, ion cyclotron resonance booster, and magnetic nozzle as well as used to explore physical phenomena in the plume such as ion/electron detachment, plasma turbulence, and magnetic field line stretching. Typical plume parameters range up to 10^13 cm-3 electron density, 1 kG applied magnetic fields, ion energies in excess of 150 eV, and cold electrons (2 -- 5 eV) with a spatial measurement range over 2 m.

  16. PREFACE: IX International Conference on Modern Techniques of Plasma Diagnostics and their Application

    Science.gov (United States)

    Savjolov, A. S.; Dodulad, E. I.

    2016-01-01

    The IX Conference on ''Modern Techniques of Plasma Diagnosis and their Application'' was held on 5 - 7 November, 2014 at National Research Nuclear University MEPhI (NRNU MEPhI). The goal of the conference was an exchange of information on both high-temperature and low-temperature plasma diagnostics as well as deliberation and analysis of various diagnostic techniques and their applicability in science, industry, ecology, medicine and other fields. The Conference also provided young scientists from scientific centres and universities engaged in plasma diagnostics with an opportunity to attend the lectures given by the leading specialists in this field as well as present their own results and findings. The first workshop titled ''Modern problems of plasma diagnostics and their application for control of chemicals and the environment'' took place at Moscow Engineering and Physics Institute (MEPhI) in June 1998 with the support of the Section on Diagnostics of the Council of Russian Academic of Science on Plasma Physics and since then these forums have been held at MEPhI every two years. In 2008 the workshop was assigned a conference status. More than 150 specialists on plasma diagnostics and students took part in the last conference. They represented leading Russian scientific centres (such as Troitsk Institute of Innovative and Thermonuclear Research, National Research Centre ''Kurchatov Institute'', Russian Federal Nuclear Centre - All-Russian Scientific Research Institute of Experimental Physics and others) and universities from Belarus, Ukraine, Germany, USA, Belgium and Sweden. About 30 reports were made by young researchers, students and post-graduate students. All presentations during the conference were broadcasted online over the internet with viewers in Moscow, Prague, St. Petersburgh and other cities. The Conference was held within the framework of the Centre of Plasma, Laser Research and Technology supported by MEPhI Academic Excellence Project (Russian

  17. Role of spectroscopic diagnostics in studying nanosecond laser-plasma interaction

    Science.gov (United States)

    Burger, Miloš; Pantić, Dragan; Nikolić, Zoran; Djeniže, Stevan

    2017-05-01

    We studied the impact of varying the intensity of Nd:YAG nanosecond 1.06 μm laser radiation on the morphology and internal structure of copper plasma plumes were examined. Standard diagnostic techniques used to deduce axial distributions of electron density and temperature revealed effects of a pronounced plasma screening regime. Methods of fast imaging spectroscopy are used to examine the transition from weak- to high-screening plasma, applying irradiance on the order of 109 W cm-2 in helium atmosphere. Behavior of both ionized and neutral species was observed up to 1 μs after the laser pulse. Showing significant differences with an increase of laser irradiance, the change in plasma propagation mechanisms is attributed to internal shockwave dynamics within the plasma plume. Implications of observed behavior to plasma uniformity can affect diagnostics, and are relevant to both modeling and applications. Contribution to the Topical Issue "Physics of Ionized Gases (SPIG 2016)", edited by Goran Poparic, Bratislav Obradovic, Dragana Maric and Aleksandar Milosavljevic.

  18. The Multiple Resonance Probe: A Novel Device for Industry Compatible Plasma Diagnostics

    Science.gov (United States)

    Brinkmann, Ralf Peter; Storch, Robert; Lapke, Martin; Oberrath, Jens; Schulz, Christian; Styrnoll, Tim; Zietz, Christian; Awakowicz, Peter; Musch, Thomas; Mussenbrock, Thomas; Rolfes, Ilona

    2012-10-01

    To be useful for the supervision or control of technical plasmas, a diagnostic method must be i) robust and stable, ii) insensitive to perturbation by the process, iii) itself not perturbing the process, iv) clearly and easily interpretable without the need for calibration, v) compliant with the requirements of process integration, and, last but not least, vi) economical in terms of investment, footprint, and maintenance. Plasma resonance spectroscopy, exploiting the natural ability of plasmas to resonate on or near the electron plasma frequency, provides a good basis for such an ``industry compatible'' plasma diagnostics. The contribution will describe the general idea of active plasma resonance spectroscopy and introduce a mathematical formalism for its analysis. It will then focus on the novel multipole resonance probe (MRP), where the excited resonances can be classified explicitly and the connection between the probe response and the desired electron density can be cast as a simple formula. The current state of the MRP project will be described, including the experimental characterization of a prototype in comparison with Langmuir probes, and the development of a specialized measurement circuit.

  19. Radial scanning diagnostics of bremsstrahlung and line emission in T-10 plasma

    Energy Technology Data Exchange (ETDEWEB)

    Nemets, A. R., E-mail: Nemets-AR@nrcki.ru; Krupin, V. A.; Klyuchnikov, L. A., E-mail: lklyuchnikov@list.ru; Korobov, K. V.; Nurgaliev, M. R. [National Research Centre Kurchatov Institute, Institute of Tokamak Physics (Russian Federation)

    2016-12-15

    The paper describes the scanning spectroscopic diagnostics designed for measurement of line integrated plasma radiation in two visible spectral ranges. This diagnostic system is aimed at measuring the bremsstrahlung absolute values and profile with high spatial resolution. The bremsstrahlung absolute values are used to determine the value and radial distribution of effective plasma ion charge Z{sub eff}(r) in T-10 discharges. The importance of Z{sub eff} measurement is due to its strong influence on plasma heating, confinement, and stability. The spatial distribution of emission for one of the chosen spectral lines is measured simultaneously with bremsstrahlung. The spatial resolution of measurements is ~1 cm, and the temporal resolution is up to 10 ms. The spectral equipment and methods for its calibration are described. Examples of line integrated brightness distribution in a “continuum window” of 5236 ± 6 Å and brightness of the lines C{sup 5+} (5291 Å), He{sup 1+} (4686 Å), and D{sub β} (4861 Å) are given. Flattening of the bremsstrahlung brightness profile in the central region of the plasma column in some discharges with sawtooth oscillations in the T-10 is observed. The measured effective ion charge profiles in ohmic discharges with high plasma density and low discharge currents demonstrate accumulation of light impurities at the column axis; as a consequence, quenching of sawtooth oscillations in some discharges is observed. The developed diagnostics provides necessary data for investigation of heat, particle, and current transport in the plasma of the T-10. Successful application of the obtained data on Z{sub eff}(r) for investigation of geodesic acoustic modes of plasma oscillations in the T-10 should be specially noted.

  20. Diagnostic Suite for HyperV Coaxial Plasma Gun Development for the PLX- α Project

    Science.gov (United States)

    Case, Andrew; Brockington, Sam; Witherspoon, F. Douglas

    2015-11-01

    We present the diagnostic suite to be used during development of the coaxial guns HyperV will deliver to LANL in support of the ARPA-E Accelerating Low-Cost Plasma Heating And Assembly (ALPHA) program. For plasma jet diagnostics this includes fast photodiodes for velocimetry, a ballistic pendulum for measuring total plasmoid momentum, interferometry for line integrated plasma density, deflectometry for line integrated perpendicular density gradient measurements, and spectroscopy, both time resolved high resolution spectroscopy using a novel detector developed by HyperV and time integrated survey spectroscopy, for measurements of velocity and temperature as well as impurities. In addition, we plan to use fast pressure probes for stagnation pressure, a Faraday cup for density, fast imaging for plume geometry and time integrated imaging for overall light emission. A novel low resolution long record length camera developed by HyperV will also be used for plume diagnostics. For diagnostics of gun operation, we will use Rogowski coils to measure current, voltage dividers for voltages, B-dot probes for magnetic field, and time resolved fast photodiodes to measure plasmoid velocity inside the accelerator. This work supported by the ARPA-E ALPHA program.

  1. Edge and Plasma -Wall Interaction Diagnostics in the TJ-II Stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Tabares, F. L.; Tafalla, D.; Branas, B.; Hidalgo, A.; Garcia-Cortes, I.; Lopez-Fraguas, A.; Ortiz, P.

    2003-07-01

    The operation of the TJ-II stellarator, carried out under ECR heating conditions until now, the plasma edge parameters and those processes has been identified. Therefore, an important , has implieda careful control of partied e sources and the associated plasma-wall interaction processes. A clear coupling between the plasma edge parameters and those processes has been identified. Therefore, an important effort has been devoted to the development of dedicated diagnostics in both fields. Remarkable success has been attained in the development of atomic-beam based edge diagnostics, namely, thermal Li and supersonic He beams. In particular, fast (up to 200 Hz) sampling of temperature and density profiles has been made possible thorough an upgraded version of the pulsed, supersonic He beam diagnostic. In this paper, whorl devoted to the upgrading of these techniques is described. Also, preliminary experiments oriented to the validation of the collisional radiative models use din the beam-based diagnostic interpretaron as well as simulations of Laser Induced Fluorescence (LIF) studies of level populations of electronically excited He atoms are shown. (Author) 17 refs.

  2. Proceedings of the fifth Australia-Japan workshop on plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The fifth Australia-Japan Workshop on Plasma Diagnostics was held at Japan Atomic Energy Research Institute (JAERI), Naka, Japan, from December 15 to 17 in 1999. The first workshop was held at JAERI, Naka in 1989, and the workshops have been held almost every two years in Australia and Japan under the Agreement between the Government of Japan and the Government of Australia on cooperation in the field of Science and Technology. In the workshops, latest research works for plasma diagnostics and plasma experiment have been presented and discussed. The research works of both countries have been developed, and the mutual understanding became deeper through the workshops. In the fifth workshop, the statuses of JT-60U (JAERI), LHD (National Institute for Fusion Science) and H-1NF (Australian National University) were introduced, and the latest research works for plasma diagnostics were also presented. The active and deeper discussions were performed. This report contains twenty-eight papers presented at the workshop. The 25 of the presented papers are indexed individually. (J.P.N.)

  3. Influence of plasma diagnostics and constraints on the quality of equilibrium reconstructions on Joint European Torus

    Energy Technology Data Exchange (ETDEWEB)

    Gelfusa, M.; Gaudio, P.; Peluso, E. [Associazione EURATOM-ENEA, University of Rome “Tor Vergata”, Roma (Italy); Murari, A.; Baruzzo, M. [Consorzio RFX-Associazione EURATOM ENEA per la Fusione, I-35127 Padova (Italy); Lupelli, I.; Hawkes, N.; Brix, M.; Drozdov, V.; Meigs, A.; Romanelli, M. [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Craciunescu, T. [EURATOM-MEdC Association, NILPRP, Bucharest (Romania); Schmuck, S.; Sieglin, B. [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, EURATOM Association, Wendelsteinstr.1, 17491 Greifswald (Germany); Collaboration: JET-EFDA Contributors

    2013-10-15

    One of the main approaches to thermonuclear fusion relies on confining high temperature plasmas with properly shaped magnetic fields. The determination of the magnetic topology is, therefore, essential for controlling the experiments and for achieving the required performance. In Tokamaks, the reconstruction of the fields is typically formulated as a free boundary equilibrium problem, described by the Grad-Shafranov equation in toroidal geometry and axisymmetric configurations. Unfortunately, this results in mathematically very ill posed problems and, therefore, the quality of the equilibrium reconstructions depends sensitively on the measurements used as inputs and on the imposed constraints. In this paper, it is shown how the different diagnostics (Magnetics Measurements, Polarimetry and Motional Stark Effect), together with the edge current density and plasma pressure constraints, can have a significant impact on the quality of the equilibrium on JET. Results show that both the Polarimetry and Motional Stark Effect internal diagnostics are crucial in order to obtain reasonable safety factor profiles. The impact of the edge current density constraint is significant when the plasma is in the H-mode of confinement. In this plasma scenario the strike point positions and the plasma last closed flux surface can change even by centimetres, depending on the edge constraints, with a significant impact on the remapping of the equilibrium-dependent diagnostics and of pedestal physics studies. On the other hand and quite counter intuitively, the pressure constraint can severely affect the quality of the magnetic reconstructions in the core. These trends have been verified with several JET discharges and consistent results have been found. An interpretation of these results, as interplay between degrees of freedom and available measurements, is provided. The systematic analysis described in the paper emphasizes the importance of having sufficient diagnostic inputs and of

  4. Additive manufacture (3d printing) of plasma diagnostic components and assemblies for fusion experiments

    Science.gov (United States)

    Sieck, Paul; Woodruff, Simon; Stuber, James; Romero-Talamas, Carlos; Rivera, William; You, Setthivoine; Card, Alexander

    2015-11-01

    Additive manufacturing (or 3D printing) is now becoming sufficiently accurate with a large range of materials for use in printing sensors needed universally in fusion energy research. Decreasing production cost and significantly lowering design time of energy subsystems would realize significant cost reduction for standard diagnostics commonly obtained through research grants. There is now a well-established set of plasma diagnostics, but these expensive since they are often highly complex and require customization, sometimes pace the project. Additive manufacturing (3D printing) is developing rapidly, including open source designs. Basic components can be printed for (in some cases) less than 1/100th costs of conventional manufacturing. We have examined the impact that AM can have on plasma diagnostic cost by taking 15 separate diagnostics through an engineering design using Conventional Manufacturing (CM) techniques to determine costs of components and labor costs associated with getting the diagnostic to work as intended. With that information in hand, we set about optimizing the design to exploit the benefits of AM. Work performed under DOE Contract DE-SC0011858.

  5. Construction, calibration, and application of a compact spectrophotometer for EUV (300-2500-A) plasma diagnostics.

    Science.gov (United States)

    Moos, H W; Chen, K I; Terry, J L; Fastie, W G

    1979-04-15

    A 400-mm normal incidence concave grating spectrophotometer, specifically designed for plasma diagnostics, is described. The wavelength drive, in which the grating is translated as well as rotated, is discussed in detail; the wavelength linearity of the sine drive and methods of improving it are analyzed. The instrument can be used in any orientation, is portable under vacuum, and quite rugged. The construction techniques utilized produce a high quality vacuum making the instrument compatible with both high purity plasma devices and synchrotron radiation sources. The photometric sensitivity calibration was found to be very stable during extended use on high temperature plasma devices. The applications of the instrument to diagnose plasmas in two tokamaks and a mirror device are described. A facility used for photometric calibration of extreme ultraviolet (lambda > 300-A) spectrophotometers against NBS standard diodes is described. The instrumental calibration obtained using this facility was checked by using synchrotron radiation from SURF II; very good agreement was observed.

  6. Papers presented at the eleventh topical conference on high-temperature plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This report contains the following eleven papers presented at the conference: Neutral Beam Diagnostics for Alcator C-Mod; A Study for the Installation of the TEXT HIBP on DIII-D; Time-domain Triple-probe Measurement of Edge Plasma Turbulence on TEXT-U; A Langmuir/Mach Probe Array for Edge Plasma Turbulence and Flow; Determination of Field Line Location and Safety Factor in TEXT-U; Hybrid ECE Imaging Array System for TEXT-U; First Results from the Phase Contrast Imaging System on TEXT-U; A Fast Tokamak Plasma Flux and Electron Density Reconstruction Technique; Time-series Analysis of Nonstationary Plasma Fluctuations Using Wavelet Transforms; Quantitative Modeling of 3-D Camera Views for Tokamak Divertors; and Variable-frequency Complex Demodulation Technique for Extracting Amplitude and Phase Information. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  7. Diagnostic performance of plasma mi-R499 for acute myocardial infarction

    Institute of Scientific and Technical Information of China (English)

    韩志君

    2014-01-01

    Objective To evaluate the diagnostic performance of plasma miR-499 in acute myocardial infarction(AMI)diagnosis.Methods Diagnostic accuracy test was used.The suspected AMI patients,who with chest pain for more than half an hour and been admitted in the SecondPeople’s Hospital of Wuxi and First People’s Hospital of Chuzhou during October 2010 and July 2011,were consecutively and prospectively enrolled in the present study.Sixty apparently healthy individuals were designed as healthy

  8. Neutral Beam Source and Target Plasma for Development of a Local Electric Field Fluctuation Diagnostic

    Science.gov (United States)

    Bakken, M. R.; Burke, M. G.; Fonck, R. J.; Lewicki, B. T.; Rhodes, A. T.; Winz, G. R.

    2016-10-01

    A new diagnostic measuring local E-> (r , t) fluctuations is being developed for plasma turbulence studies in tokamaks. This is accomplished by measuring fluctuations in the separation of the π components in the Hα motional Stark spectrum. Fluctuations in this separation are expected to be Ẽ / ẼEMSE 10-3EMSE 10-3 . In addition to a high throughput, high speed spectrometer, the project requires a low divergence (Ω 0 .5°) , 80 keV, 2.5 A H0 beam and a target plasma test stand. The beam employs a washer-stack arc ion source to achieve a high species fraction at full energy. Laboratory tests of the ion source demonstrate repeatable plasmas with Te 10 eV and ne 1.6 ×1017 m-3, sufficient for the beam ion optics requirements. Te and ne scalings of the ion source plasma are presented with respect to operational parameters. A novel three-phase resonant converter power supply will provide 6 mA/cm2 of 80 keV H0 at the focal plane for pulse lengths up to 15 ms, with low ripple δV / 80 keV 0.05 % at 280 kHz. Diagnostic development and validation tests will be performed on a magnetized plasma test stand with 0.5 T field. The test chamber will utilize a washer-stack arc source to produce a target plasma comparable to edge tokamak plasmas. A bias-plate with programmable power supply will be used to impose Ẽ within the target plasma. Work supported by US DOE Grant DE-FG02-89ER53296.

  9. Far infrared fusion plasma diagnostics. Task 3A, Progress report, FY 1990

    Energy Technology Data Exchange (ETDEWEB)

    Luhmann, N.C. Jr.; Peebles, W.A.

    1990-12-31

    Over the last several years, reflectometry has grown in importance as a diagnostic for both steady-state density Profiles as well as for the investigation of density fluctuations and turbulence. As a diagnostic for density profile measurement, it is generally believed to be well understood in the tokamak environment. However, its use as a fluctuation diagnostic is hampered by a lack of quantitative experimental understanding of its wavenumber sensitivity and spatial resolution. Several researchers, have theoretically investigated these questions. However, prior to the UCLA laboratory investigation, no group has experimentally investigated these questions. Because of the reflectometer`s importance to the world effort in understanding plasma turbulence and transport, UCLA has, over the last year, made its primary Task IIIA effort the resolution of these questions. UCLA has taken the lead in a quantitative experimental understanding of reflectometer data as applied to the measurement of density fluctuations. In addition to this, work has proceeded on the design, construction, and installation of a reflectometer system on UCLA`s CCT tokamak. This effort will allow a comparison between the improved confinement regimes (H-mode) observed on both the DIII-D and CCT machines with the goal of achieving a physics understanding of the phenomena. Preliminary investigation of a new diagnostic technique to measure density profiles as a function of time has been initiated at UCLA. The technique promises to be a valuable addition to the range of available plasma diagnostics. Work on advanced holographic reflectometry technique as applied to fluctuation diagnostics has awaited a better understanding of the reflectometer signal itself as discussed above. Efforts to ensure the transfer of the diagnostic developments have continued with particular attention devoted to the preliminary design of a multichannel FIR interferometer for MST.

  10. Statistical analysis of polarizing maps of blood plasma laser images for the diagnostics of malignant formations

    Science.gov (United States)

    Ungurian, V. P.; Ivashchuk, O. I.; Ushenko, V. O.

    2012-01-01

    This work is aimed at searching the interconnections between the statistic structure of blood plasma microscopic images and manifestations of optical anisotropy of liquid crystal protein network. The model of linear birefringence of albumin and globulin crystals underlies in the ground of this work. The results of investigating the interrelation between statistical moments of the 1st-4th order are presented that characterize the coordinate distributions of polarization ellipticity of laser images of blood plasma smears and pathological changes in human organism. The diagnostic criteria of breast cancer nascency and its severity degree differentiation are determined.

  11. Absolute calibration of space-resolving soft X-ray spectrograph for plasma diagnostics

    Science.gov (United States)

    Yoshikawa, M.; Okamoto, Y.; Kawamori, E.; Watanabe, Y.; Watabe, C.; Yamaguchi, N.; Tamano, T.

    2001-07-01

    A grazing incidence flat-field soft X-ray (20-350 Å) spectrograph was constructed and applied for impurity diagnostics in the GAMMA 10 fusion plasma. The spectrograph consisted of a limited height entrance slit, an aberration-corrected concave grating, a microchannel-plate intensified detector and an instant camera/a high speed solid state camera. An absolute calibration experiment for the SX spectrograph was performed at the Photon Factory in the High Energy Accelerator Research Organization with monitoring the incident synchrotron beam intensity by using an absolutely calibrated XUV silicon photodiode. From the results of absolute calibration of the spectrograph, the radiation loss from the plasma was obtained.

  12. Absolute calibration of space-resolving soft X-ray spectrograph for plasma diagnostics

    CERN Document Server

    Yoshikawa, M; Kawamori, E; Watanabe, Y; Watabe, C; Yamaguchi, N; Tamano, T

    2001-01-01

    A grazing incidence flat-field soft X-ray (20-350 A) spectrograph was constructed and applied for impurity diagnostics in the GAMMA 10 fusion plasma. The spectrograph consisted of a limited height entrance slit, an aberration-corrected concave grating, a microchannel-plate intensified detector and an instant camera/a high speed solid state camera. An absolute calibration experiment for the SX spectrograph was performed at the Photon Factory in the High Energy Accelerator Research Organization with monitoring the incident synchrotron beam intensity by using an absolutely calibrated XUV silicon photodiode. From the results of absolute calibration of the spectrograph, the radiation loss from the plasma was obtained.

  13. Formation of Imploding Plasma Liners for HEDP and MIF Applications - Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Gilmore, Mark [Univ. of New Mexico, Albuquerque, NM (United States). Dept. of Electrical and Computer Engineering. Dept. of Physics and Astronomy; Hsu, Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Witherspoon, F. Douglas [HyperV Technologies Corp., Chantilly, VA (United States); Cassibry, Jason [Univ. of Alabama, Huntsville, AL (United States); Bauer, Bruno S. [Univ. of Nevada, Reno, NV (United States)

    2015-04-27

    The goal of the plasma liner experiment (PLX) was to explore and demonstrate the feasibility of forming imploding spherical plasma liners that can reach High Energy Density (HED)-relevant (~ 0.1 Mbar) pressures upon stagnation. The plasma liners were to be formed by a spherical array of 30 – 36 railgun-driven hypervelocity plasma jets (Mach 10 – 50). Due to funding and project scope reductions in year two of the project, this initial goal was revised to focus on studies of individual jet propagation, and on two jet merging physics. PLX was a collaboration between a number of partners including Los Alamos National Laboratory, HyperV Technologies, University of New Mexico (UNM), University of Alabama, Huntsville, and University of Nevada, Reno. UNM’s part in the collaboration was primary responsibility for plasma diagnostics. Though full plasma liner experiments could not be performed, the results of single and two jet experiments nevertheless laid important groundwork for future plasma liner investigations. Though challenges were encountered, the results obtained with one and two jets were overwhelmingly positive from a liner formation point of view, and were largely in agreement with predictions of hydrodynamic models.

  14. Towards personalized diagnostics via longitudinal study of the human plasma N-glycome.

    Science.gov (United States)

    Hennig, René; Cajic, Samanta; Borowiak, Matthias; Hoffmann, Marcus; Kottler, Robert; Reichl, Udo; Rapp, Erdmann

    2016-08-01

    Facilitated by substantial advances in analytical methods, plasma N-glycans have emerged as potential candidates for biomarkers. In the recent years, several investigations could link aberrant plasma N-glycosylation to numerous diseases. However, due to often limited specificity and sensitivity, only a very limited number of glycan biomarkers were approved by the authorities up to now. The inter-individual heterogeneity of the plasma N-glycomes might mask disease related changes in conventional large cross-sectional cohort studies, with a one-time sampling approach. But, a possible benefit of longitudinal sampling in biomarker discovery could be, that already small changes during disease progression are revealed, by monitoring the plasma N-glycome of individuals over time. To evaluate this, we collected blood plasma samples of five healthy donors over a time period of up to six years (min. 1.5 years). The plasma N-glycome was analyzed by xCGE-LIF, to investigate the intra-individual N-glycome variability over time. It is shown, that the plasma N-glycome of an individual is remarkably stable over a period of several years, and that observed small longitudinal changes are independent from seasons, but significantly correlated with lifestyle and environmental factors. Thus, the potential of future longitudinal biomarker discovery studies could be demonstrated, which is a further step towards personalized diagnostics. This article is part of a Special Issue entitled "Glycans in personalised medicine" Guest Editor: Professor Gordan Lauc.

  15. Influence of electron injection into 27 cm audio plasma cell on the plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Haleem, N. A.; Ragheb, M. S.; Zakhary, S. G. [Accelerators Department, Nuclear Research Center, AEA, Cairo 13759 (Egypt); El Fiki, S. A.; Nouh, S. A. [Faculty of Science, Ain Shams University, Cairo 11566 (Egypt); El Disoki, T. M. [Faculty of Girls, Ain Shams University, Cairo 11566 (Egypt)

    2013-08-15

    In this article, the plasma is created in a Pyrex tube (L = 27 cm, φ= 4 cm) as a single cell, by a capacitive audio frequency (AF) discharge (f = 10–100 kHz), at a definite pressure of ∼0.2 Torr. A couple of tube linear and deviating arrangements show plasma characteristic conformity. The applied AF plasma and the injection of electrons into two gas mediums Ar and N{sub 2} revealed the increase of electron density at distinct tube regions by one order to attain 10{sup 13}/cm{sup 3}. The electrons temperature and density strengths are in contrast to each other. While their distributions differ along the plasma tube length, they show a decaying sinusoidal shape where their peaks position varies by the gas type. The electrons injection moderates electron temperature and expands their density. The later highest peak holds for the N{sub 2} gas, at electrons injection it changes to hold for the Ar. The sinusoidal decaying density behavior generates electric fields depending on the gas used and independent of tube geometry. The effect of the injected electrons performs a responsive impact on electrons density not attributed to the gas discharge. Analytical tools investigate the interaction of the plasma, the discharge current, and the gas used on the electrodes. It points to the emigration of atoms from each one but for greater majority they behave to a preferred direction. Meanwhile, only in the linear regime, small percentage of atoms still moves in reverse direction. Traces of gas atoms revealed on both electrodes due to sheath regions denote lack of their participation in the discharge current. In addition, atoms travel from one electrode to the other by overcoming the sheaths regions occurring transportation of particles agglomeration from one electrode to the other. The electrons injection has contributed to increase the plasma electron density peaks. These electrons populations have raised the generated electrostatic fields assisting the elemental ions

  16. Plasma globotriaosylsphingosine: diagnostic value and relation to clinical manifestations of Fabry disease.

    Science.gov (United States)

    Rombach, S M; Dekker, N; Bouwman, M G; Linthorst, G E; Zwinderman, A H; Wijburg, F A; Kuiper, S; Vd Bergh Weerman, M A; Groener, J E M; Poorthuis, B J; Hollak, C E M; Aerts, J M F G

    2010-09-01

    Fabry disease is an X-linked lysosomal storage disorder due to deficiency of alpha-Galactosidase A, causing accumulation of globotriaosylceramide and elevated plasma globotriaosylsphingosine (lysoGb3). The diagnostic value and clinical relevance of plasma lysoGb3 concentration was investigated. All male and adult female patients with classical Fabry disease could be discerned by an elevated plasma lysoGb3. In young pre-symptomatic Fabry heterozygotes, lysoGb3 levels can be normal. Individuals carrying the R112H and P60L mutations, without classical Fabry symptoms, showed no elevated plasma lysoGb3. Multiple regression analysis showed that there is no correlation of plasma lysoGb3 concentration with total disease severity score in Fabry males. However, plasma lysoGb3 concentration did correlate with white matter lesions (odds ratio: 6.1 per 100 nM lysoGb3 increase (95% CI: 1.4-25.9, p=0.015). In females, plasma lysoGb3 concentration correlated with overall disease severity. Furthermore, plasma lysoGb3 level was related to left ventricular mass (19.5+/-5.5 g increase per 10 nM lysoGb3 increase; p=0.001). In addition, it was assessed whether lifetime exposure to lysoGb3 correlates with disease manifestations. Male Fabry patients with a high lysoGb3 exposure (>10,000 U), were moderately or severely affected, only one mildly. Female patients with a low exposure (1000 U showed disease complications. Plasma lysoGb3 is useful for the diagnosis of Fabry disease. LysoGb3 is an independent risk factor for development of cerebrovascular white matter lesions in male patients and left ventricular hypertrophy in females. Disease severity correlates with exposure to plasma lysoGb3.

  17. Extreme ultraviolet and soft x-ray diagnostics of high-temperature plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Moos, W.

    1986-10-02

    This report describes recent progress and plans for calendar year 1987 in the Johns Hopkins University program to develop and improve spectroscopic diagnostics for the high temperature plasmas used in magnetic fusion research. An EUV spectrograph which provides time resolved spectra along fifteen chords of a plasma device has been completed and evaluation on DIII-D will began in late 1986. Other instrumentation work includes the evaluation of a sensitive detector for ion temperature/velocity distribution determinations and a feasibility study of Zeeman polarimetry for determining magnetic fields. A comprehensive data set taken on the TEXT tokamak is undergoing analysis as a means of improving the ionic parameters used in diagnostic studies and to expand the capabilities of existing instruments. Potential new advanced in spectroscopic technology are being monitored to determine if they provide advantages for fusion research.

  18. Extreme ultraviolet and soft x-ray diagnostics of high-temperature plasmas. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Moos, W.

    1986-10-02

    This report describes recent progress and plans for calendar year 1987 in the Johns Hopkins University program to develop and improve spectroscopic diagnostics for the high temperature plasmas used in magnetic fusion research. An EUV spectrograph which provides time resolved spectra along fifteen chords of a plasma device has been completed and evaluation on DIII-D will began in late 1986. Other instrumentation work includes the evaluation of a sensitive detector for ion temperature/velocity distribution determinations and a feasibility study of Zeeman polarimetry for determining magnetic fields. A comprehensive data set taken on the TEXT tokamak is undergoing analysis as a means of improving the ionic parameters used in diagnostic studies and to expand the capabilities of existing instruments. Potential new advanced in spectroscopic technology are being monitored to determine if they provide advantages for fusion research.

  19. Size-based molecular diagnostics using plasma DNA for noninvasive prenatal testing.

    Science.gov (United States)

    Yu, Stephanie C Y; Chan, K C Allen; Zheng, Yama W L; Jiang, Peiyong; Liao, Gary J W; Sun, Hao; Akolekar, Ranjit; Leung, Tak Y; Go, Attie T J I; van Vugt, John M G; Minekawa, Ryoko; Oudejans, Cees B M; Nicolaides, Kypros H; Chiu, Rossa W K; Lo, Y M Dennis

    2014-06-10

    Noninvasive prenatal testing using fetal DNA in maternal plasma is an actively researched area. The current generation of tests using massively parallel sequencing is based on counting plasma DNA sequences originating from different genomic regions. In this study, we explored a different approach that is based on the use of DNA fragment size as a diagnostic parameter. This approach is dependent on the fact that circulating fetal DNA molecules are generally shorter than the corresponding maternal DNA molecules. First, we performed plasma DNA size analysis using paired-end massively parallel sequencing and microchip-based capillary electrophoresis. We demonstrated that the fetal DNA fraction in maternal plasma could be deduced from the overall size distribution of maternal plasma DNA. The fetal DNA fraction is a critical parameter affecting the accuracy of noninvasive prenatal testing using maternal plasma DNA. Second, we showed that fetal chromosomal aneuploidy could be detected by observing an aberrant proportion of short fragments from an aneuploid chromosome in the paired-end sequencing data. Using this approach, we detected fetal trisomy 21 and trisomy 18 with 100% sensitivity (T21: 36/36; T18: 27/27) and 100% specificity (non-T21: 88/88; non-T18: 97/97). For trisomy 13, the sensitivity and specificity were 95.2% (20/21) and 99% (102/103), respectively. For monosomy X, the sensitivity and specificity were both 100% (10/10 and 8/8). Thus, this study establishes the principle of size-based molecular diagnostics using plasma DNA. This approach has potential applications beyond noninvasive prenatal testing to areas such as oncology and transplantation monitoring.

  20. An accurate automated technique for quasi-optics measurement of the microwave diagnostics for fusion plasma

    Science.gov (United States)

    Hu, Jianqiang; Liu, Ahdi; Zhou, Chu; Zhang, Xiaohui; Wang, Mingyuan; Zhang, Jin; Feng, Xi; Li, Hong; Xie, Jinlin; Liu, Wandong; Yu, Changxuan

    2017-08-01

    A new integrated technique for fast and accurate measurement of the quasi-optics, especially for the microwave/millimeter wave diagnostic systems of fusion plasma, has been developed. Using the LabVIEW-based comprehensive scanning system, we can realize not only automatic but also fast and accurate measurement, which will help to eliminate the effects of temperature drift and standing wave/multi-reflection. With the Matlab-based asymmetric two-dimensional Gaussian fitting method, all the desired parameters of the microwave beam can be obtained. This technique can be used in the design and testing of microwave diagnostic systems such as reflectometers and the electron cyclotron emission imaging diagnostic systems of the Experimental Advanced Superconducting Tokamak.

  1. Papers presented at the Tenth Topical Conference on High-Temperature Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    1994-08-01

    This report contains papers on the following topics: Effects of limited spatial resolution on fluctuation measurements; vertical viewing of electron-cyclotron radiation in Text-U; measurement of temperature fluctuations from electron-cyclotron emission; a varying cross section magnetic coil diagnostic used in digital feedback control of plasma position in Text-Upgrade; high-sensitivity, high resolution measurements of radiated power on Text-U; wave launching as a diagnostic tool to investigate plasma turbulence; edge parameters from an energy analyzer and particle transport on Text-U; initial results from a charge exchange q-Diagnostic on Text-U; a method for neutral spectra analysis taking ripple-trapped particle losses into account; application of a three sample volume{sup S(k,{omega}}) estimate to optical measurements of turbulence on Text; initial operation of the 2D Firsis on Text-Upgrade; horizontal-view interferometer on Text-Upgrade; plasma potential measurements on Text-Upgrade with A 2 MeV heavy ion beam; fluctuation measurements using the 2 MeV heavy ion beam probe on Text-U; the time domain triple probe method; a phase contrast imaging system for Text-U; and development of rugged corner cube detectors for the Text-U-Fir interferometer. These papers have been placed on the database elsewhere.

  2. Serum lactate as predictor and diagnostic biomarker of plasma leakage in adult dengue patients

    Directory of Open Access Journals (Sweden)

    Rika Bur

    2016-12-01

    Full Text Available Background Dengue fever (DF and dengue hemorrhagic fever (DHF are differentiated by the occurrence in DHF of plasma leakage into the interstitial space as shown by pleural and peritoneal effusion, hemoconcentration, and intravascular hypovolemia. Perfusion dysfunction causes anaerobic metabolism, which leads to increased serum lactate. This study was to determine serum lactate as prognostic predictor and diagnostic biomarker of plasma leakage in adult dengue patients. Methods A cross-sectional retrospective cohort study was conducted on 57 adult dengue patients hospitalized in the internal medicine ward of Cipto Mangunkusumo Hospital and Persahabatan Hospital in Jakarta. Serum lactate was examined to determine its mean difference between DF and DHF. The data was analyzed by independent t-test and the cut-off points were identified for presence as well as absence of plasma leakage, then the receiver operating characteristics (ROC curve was used to determine sensitivity and specificity. Results Mean serum lactate was significantly higher in DHF than in DF. From the ROC curve, the cut-off point for serum lactate as prognostic predictor on day 3 of fever was ³2.65 mmol/L with AUC of 0.626 (95% CI 0.480-0.772; p=0.108. The cut-off point for diagnostic biomarker of plasma leakage on day 5 of fever was ³2.55 mmol/L with sensitivity 66.6%, specificity 54.2%, and AUC 0.668 (95% CI 0.550-0.826; p=0.016. Conclusion There was a significant difference in serum lactate between DF and DHF. In the critical phase, serum lactate of ³2.55 mmol/L could be used as plasma leakage diagnostic marker of low accuracy.

  3. Modeling and Simulation for Nanoparticle Plasma Jet Diagnostic Probe for Runaway Electron Beam-Plasma Interaction

    Science.gov (United States)

    Bogatu, I. N.; Galkin, S. A.

    2016-10-01

    The C60 nanoparticle plasma jet (NPPJ) rapid injection into a tokamak major disruption is followed by C60 gradual fragmentation along plasma-traversing path. The result is abundant C ion concentration in the core plasma enhancing the potential to probe and diagnose the runaway electrons (REs) during different phases of their dynamics. A C60/C NPPJ of 75 mg, high-density (>1023 m-3) , hyper-velocity (>4 km/s), and uniquely fast response-to-delivery time ( 1 ms) has been demonstrated on a test bed. It can rapidly and deeply deliver enough mass to increase electron density to 2.4x1021 m-3, 60 times larger than typical DIII-D pre-disruption value. We will present the results of our on-going work on: 1) self-consistent model for RE current density evolution (by Dreicer mechanism and ``avalanche'') focused on the effect of fast and deep deposition of C ions, 2) improvement of single C60q+ fragmenting ion penetration model through tokamak B(R)-field and post-TQ plasma, and 3) simulation of C60q+ PJ penetration through the DIII-D characteristic 2 T B-field to the RE beam central location by using the Hybrid Electro-Magnetic 2D code (HEM-2D. Work supported by US DOE DE-SC0015776 Grant.

  4. Limited Diagnostic Utility of Plasma Adrenocorticotropic Hormone for Differentiation between Adrenal Cushing Syndrome and Cushing Disease.

    Science.gov (United States)

    Hong, A Ram; Kim, Jung Hee; Hong, Eun Shil; Kim, I Kyeong; Park, Kyeong Seon; Ahn, Chang Ho; Kim, Sang Wan; Shin, Chan Soo; Kim, Seong Yeon

    2015-09-01

    Measurement of the plasma adrenocorticotropic hormone (ACTH) level has been recommended as the first diagnostic test for differentiating between ACTH-independent Cushing syndrome (CS) and ACTH-dependent CS. When plasma ACTH values are inconclusive, a differential diagnosis of CS can be made based upon measurement of the serum dehydroepiandrosterone sulfate (DHEA-S) level and results of the high-dose dexamethasone suppression test (HDST). The aim of this study was to assess the utility of plasma ACTH to differentiate adrenal CS from Cushing' disease (CD) and compare it with that of the HDST results and serum DHEA-S level. We performed a retrospective, multicenter study from January 2000 to May 2012 involving 92 patients with endogenous CS. The levels of plasma ACTH, serum cortisol, 24-hour urine free cortisol (UFC) after the HDST, and serum DHEA-S were measured. Fifty-seven patients had adrenal CS and 35 patients had CD. The area under the curve of plasma ACTH, serum DHEA-S, percentage suppression of serum cortisol, and UFC after HDST were 0.954, 0.841, 0.950, and 0.997, respectively (all P<0.001). The cut-off values for plasma ACTH, percentage suppression of serum cortisol, and UFC after HDST were 5.3 pmol/L, 33.3%, and 61.6%, respectively. The sensitivity and specificity of plasma ACTH measurement were 84.2% and 94.3%, those of serum cortisol were 95.8% and 90.6%, and those of UFC after the HDST were 97.9% and 96.7%, respectively. Significant overlap in plasma ACTH levels was seen between patients with adrenal CS and those with CD. The HDST may be useful in differentiating between these forms of the disease, especially when the plasma ACTH level alone is not conclusive.

  5. [Two-temperature diagnostic studies by emission spectra for nonequilibrium Ti-H plasma].

    Science.gov (United States)

    Deng, Chun-feng; Lu, Biao; Wu, Chun-lei; Wang, Yi-fu; Wen, Zhong-wei

    2014-12-01

    Using the T-H solid solution made by titanium absorbed hydrogen as the cathode, the Ti-H plasma produced by the pulsed vacuum are ion source was nonequilibrium: it contained both the component of titanium and hydrogen; there existed gradient in the radiaL, the horizontal and the time. As a result, it could not be described by a single temperature. The present paper assumed that the subsystem consisting of electrons and the subsystem consisting of other heavy particles reached equilibrium respectively, meaning that the Ti-H plasma was described by the two temperatures as electron temperature and heavy ion temperature, it was non-equilibrium two-temperature plasma Using Culdberg-Waage dissociation equation to describe the molecular dissociation process in the system, using Saha ionization equation to describe the atomic ionization process, combining plasma's charge quasi-neutral condition and introducing atomic emission spectroscopy as a plasma diagnostic method which would not interfere the plasma at the same time; the temperature and the particle number density of the Ti-H plasma were diagnosed. Using MATLAB as a tool, both the titanium atoms and monovalent titanium ions' ionization were considered, and the calculated results showed that with the electtron density determined by the Stark broadening of spectral lines in advance, except the heavy particle temperature and the hydrogen number density, the Ti-H plasma's parameters could be diagnosed fairly accurately; the accuracy of the electron density values had a great effect on the calculation results; if the heavy particle temperature could be determined in advance, the temperature and the particle number density of the Ti-H plasma could be accurately analyzed quantitatively.

  6. He-like ions as practical astrophysical plasma diagnostics: From stellar coronae to active galactic nuclei

    CERN Document Server

    Porquet, Delphine; Grosso, Nicolas; 10.1007/s11214-010-9731-2

    2011-01-01

    We review X-ray plasma diagnostics based on the line ratios of He-like ions. Triplet/singlet line intensities can be used to determine electronic temperature and density, and were first developed for the study of the solar corona. Since the launches of the X-ray satellites Chandra and XMM-Newton, these diagnostics have been extended and used (from CV to Si XIII) for a wide variety of astrophysical plasmas such as stellar coronae, supernova remnants, solar system objects, active galactic nuclei, and X-ray binaries. Moreover, the intensities of He-like ions can be used to determine the ionization process(es) at work, as well as the distance between the X-ray plasma and the UV emission source for example in hot stars. In the near future thanks to the next generation of X-ray satellites (e.g., Astro-H and IXO), higher-Z He-like lines (e.g., iron) will be resolved, allowing plasmas with higher temperatures and densities to be probed. Moreover, the so-called satellite lines that are formed closed to parent He-like ...

  7. Development of simple designs of multitip probe diagnostic systems for RF plasma characterization.

    Science.gov (United States)

    Naz, M Y; Shukrullah, S; Ghaffar, A; Rehman, N U

    2014-01-01

    Multitip probes are very useful diagnostics for analyzing and controlling the physical phenomena occurring in low temperature discharge plasmas. However, DC biased probes often fail to perform well in processing plasmas. The objective of the work was to deduce simple designs of DC biased multitip probes for parametric study of radio frequency plasmas. For this purpose, symmetric double probe, asymmetric double probe, and symmetric triple probe diagnostic systems and their driving circuits were designed and tested in an inductively coupled plasma (ICP) generated by a 13.56 MHz radio frequency (RF) source. Using I-V characteristics of these probes, electron temperature, electron number density, and ion saturation current was measured as a function of input power and filling gas pressure. An increasing trend was noticed in electron temperature and electron number density for increasing input RF power whilst a decreasing trend was evident in these parameters when measured against filling gas pressure. In addition, the electron energy probability function (EEPF) was also studied by using an asymmetric double probe. These studies confirmed the non-Maxwellian nature of the EEPF and the presence of two groups of the energetic electrons at low filling gas pressures.

  8. Development of Simple Designs of Multitip Probe Diagnostic Systems for RF Plasma Characterization

    Directory of Open Access Journals (Sweden)

    M. Y. Naz

    2014-01-01

    Full Text Available Multitip probes are very useful diagnostics for analyzing and controlling the physical phenomena occurring in low temperature discharge plasmas. However, DC biased probes often fail to perform well in processing plasmas. The objective of the work was to deduce simple designs of DC biased multitip probes for parametric study of radio frequency plasmas. For this purpose, symmetric double probe, asymmetric double probe, and symmetric triple probe diagnostic systems and their driving circuits were designed and tested in an inductively coupled plasma (ICP generated by a 13.56 MHz radio frequency (RF source. Using I-V characteristics of these probes, electron temperature, electron number density, and ion saturation current was measured as a function of input power and filling gas pressure. An increasing trend was noticed in electron temperature and electron number density for increasing input RF power whilst a decreasing trend was evident in these parameters when measured against filling gas pressure. In addition, the electron energy probability function (EEPF was also studied by using an asymmetric double probe. These studies confirmed the non-Maxwellian nature of the EEPF and the presence of two groups of the energetic electrons at low filling gas pressures.

  9. Collisional-radiative modelling for the spectroscopic diagnostic of turbulent plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Rosato, J.; Lefevre, T.; Escarguel, A.; Capes, H.; Catoire, F.; Marandet, Y.; Stamm, R. [PIIM, Universite de Provence, CNRS, Marseille (France); Rosmej, F.B. [Universite Pierre et Marie Curie, Paris (France)] [LULI, Palaiseau (France); Kadomtsev, M.B.; Levashova, M.G.; Lisitsa, V.S. [NFI, Russian Research Center, Kurchatov Institute, Moscow (Russian Federation); Bonhomme, G. [IJL, Universite de Nancy, CNRS, Vandoeuvre-les-Nancy (France)

    2011-07-01

    Spectroscopy is a diagnostic method widely used in plasma physics research, e.g. in laboratory experiments, in fusion devices or in astrophysics. Information on the plasma parameters (electron density, temperature etc.) can be obtained from the analysis of both line shapes and intensities through the use of suitable models. The aim of the present paper is to assess the role of turbulent fluctuations on line intensity ratios in the case of weakly radiating plasmas. This involves the use of collisional-radiative modelling. In the present work we address the radiation due to atomic lines in turbulent helium plasmas at low density/temperature. The statistical formalism previously used in line shape modelling is adapted in this way, and the atomic populations are calculated with a collisional-radiative code. Different regimes, according to the turbulence correlation time, have been considered. In the static case, which corresponds to low-frequency fluctuations, it has been shown that the turbulence can lead to an increase of the line intensities. An application to helium in realistic experimental conditions has revealed that line ratios are sensitive to the fluctuations, which offers a track to a diagnostic. In the dynamic case, the use of a reduced model in the case of an ideal two-level atom has revealed the possibility for a significant dependence of the atomic populations on the turbulence frequency

  10. Diagnostics of recombining laser plasma parameters based on He-like ion resonance lines intensity ratios

    Science.gov (United States)

    Ryazantsev, S. N.; Skobelev, I. Yu; Faenov, A. Ya; Pikuz, T. A.; Grum-Grzhimailo, A. N.; Pikuz, S. A.

    2016-11-01

    While the plasma created by powerful laser expands from the target surface it becomes overcooled, i.e. recombining one. Improving of diagnostic methods applicable for such plasma is rather important problem in laboratory astrophysics nowadays because laser produced jets are fully scalable to young stellar objects. Such scaling is possible because of the plasma hydrodynamic equations invariance under some transformations. In this paper it is shown that relative intensities of the resonance transitions in He-like ions can be used to measure the parameters of recombining plasma. Intensity of the spectral lines corresponding to these transitions is sensitive to the density in the range of 1016-1020 cm-3 while the temperature ranges from 10 to 100 eV for ions with nuclear charge Zn ∼ 10. Calculations were carried out for F VIII ion and allowed to determine parameters of plasma jets created by nanosecond laser system ELFIE (Ecole Polytechnique, France) for astrophysical phenomenon modelling. Obtained dependencies are quite universal and can be used for any recombining plasma containing He-like fluorine ions.

  11. PIC Simulation of RF Plasma Sheath Formation and Initial Validation of Optical Diagnostics using HPC Resources

    Science.gov (United States)

    Icenhour, Casey; Exum, Ashe; Martin, Elijah; Green, David; Smithe, David; Shannon, Steven

    2014-10-01

    The coupling of experiment and simulation to elucidate near field physics above ICRF antennae presents challenges on both the experimental and computational side. In order to analyze this region, a new optical diagnostic utilizing active and passive spectroscopy is used to determine the structure of the electric fields within the sheath region. Parallel and perpendicular magnetic fields with respect to the sheath electric field have been presented. This work focuses on the validation of these measurements utilizing the Particle-in-Cell (PIC) simulation method in conjunction with High Performance Computing (HPC) resources on the Titan supercomputer at Oak Ridge National Laboratory (ORNL). Plasma parameters of interest include electron density, electron temperature, plasma potentials, and RF plasma sheath voltages and thicknesses. The plasma is modeled utilizing the VSim plasma simulation tool, developed by the Tech-X Corporation. The implementation used here is a two-dimensional electromagnetic model of the experimental setup. The overall goal of this study is to develop models for complex RF plasma systems and to help outline the physics of RF sheath formation and subsequent power loss on ICRF antennas in systems such as ITER. This work is carried out with the support of Oak Ridge National Laboratory and the Tech-X Corporation.

  12. Contribution of satellite lines to temperature diagnostics with He-like triplet lines in photoionized plasma

    Science.gov (United States)

    Wang, Feilu; Han, Bo; Salzmann, David; Zhao, Gang

    2017-04-01

    In the present paper, the He α triplet line ratios (resonance, intercombination, and forbidden lines) are computed for photoionized plasmas, when the contributions of nearby satellite lines are taken into account. The computations have been carried out with our radiative-collisional code, RCF, which is based on the flexible atomic code. The calculations of these line ratios have been done for three materials, namely, silicon, magnesium, and neon. Our calculations are used to derive the plasma temperatures for several astronomical objects, where the spectra are emitted from photoionizing plasmas. It is shown that the incorporation of the satellite lines from doubly excited Li-like ions into the He α triplet lines is necessary to obtain reliable temperature diagnostics for these astrophysical objects.

  13. Cross-diagnostic comparison of fluctuation measurements in a linear plasma column

    Science.gov (United States)

    Light, Adam D.; Archer, Nicholas A. A.; Bashyal, Atit; Chakraborty Thakur, Saikat; Tynan, George R.

    2015-11-01

    The advent of fast imaging diagnostics, which provide two-dimensional measurements on relevant plasma time scales, has proven invaluable for interpreting plasma dynamics in laboratory devices. Despite its success, imaging remains a qualitative aid for many studies, because intensity is difficult to map onto a single physical variable for use in a theoretical model. This work continues our exploration of the relationship between visible-light and electrostatic probe measurements in the Controlled Shear Decorrelation Experiment (CSDX). CSDX is a well-characterized linear machine producing dense plasmas relevant to the tokamak edge (Te ~ 3 eV, ne ~1013 /cc). Visible light from ArI and ArII line emission is collected at high frame rates using a fast digital camera. Floating potential and ion-saturation current are measured by an array of electrostatic probe tips. We present a detailed comparison between imaging and probe measurements of fluctuations, including temporal, spatial, and spectral properties in various operational regimes.

  14. Plasma DNA integrity index as a potential molecular diagnostic marker for breast cancer.

    Science.gov (United States)

    Kamel, Azza M; Teama, Salwa; Fawzy, Amal; El Deftar, Mervat

    2016-06-01

    Plasma DNA integrity index is increased in various malignancies including breast cancer, the most common cancer in women worldwide; early detection is crucial for successful treatment. Current screening methods fail to detect many cases of breast cancer at an early stage. In this study, we evaluated the level of plasma DNA integrity index in 260 females (95 with breast cancer, 95 with benign breast lesions, and 70 healthy controls) to verify its potential value in discriminating malignant from benign breast lesions. The criteria of the American Joint Committee on Cancer were used for staging of breast cancer patients. DNA integrity index was measured by real-time PCR. DNA integrity index was significantly higher in breast cancer than in benign breast patients and healthy subjects (P = cancer group was 85.3 % at 0.55 DNA integrity index cutoff. In conclusion, the plasma DNA integrity index may be a promising molecular diagnostic marker of malignancy in breast lesions.

  15. Temperature diagnostics of a non-thermal plasma jet at atmospheric pressure

    Science.gov (United States)

    Schäfer, Jan

    2013-09-01

    The study reflects the concept of the temperature as a physical quantity resulting from the second thermodynamic law. The reliability of different approaches of the temperature diagnostics of open non-equilibrium systems is discussed using examples of low temperature atmospheric pressure discharges. The focus of this work is a miniaturized non-thermal atmospheric pressure plasma jet for local surface treatment at ambient atmosphere. The micro-discharge is driven with a capacitively coupled radio frequency electric field at 27.12 MHz and fed with argon at rates of about 1 slm through the capillary with an inner diameter of 4 mm. The discharge consists of several contracted filaments with diameter around 300 μm which are rotating azimuthally in the capillary in a self-organized manner. While the measured temperatures of the filament core exceed 700 K, the heat impact on a target below the plasma jet remains limited leading to target temperatures below 400 K. Different kinds of temperatures and energy transport processes are proposed and experimentally investigated. Nevertheless, a reliable and detailed temperature diagnostics is a challenge. We report on a novel diagnostics approach for the spatially and temporally resolved measurement of the gas temperature based on the optical properties of the plasma. Laser Schlieren Deflectometry is adapted to explore temperature profiles of filaments and their behaviour. In parallel, the method demonstrates a fundamental Fermat's principle of minimal energy. Information acquired with this method plays an important role for the optimization of local thin film deposition and surface functionalization by means of the atmospheric pressure plasma jet. The work was supported in part by the Deutsche Forschungsgemeinschaft within SFB-TR 24.

  16. 13th TOPICAL CONFERENCE ON HIGH TEMPERATURE PLASMA DIAGNOSTICS SCIENTIFIC PROGRAM

    Energy Technology Data Exchange (ETDEWEB)

    C. BARNES

    2000-07-01

    Electron cyclotron emission (ECE) has been employed as a standard electron temperature profile diagnostic on many tokamaks and stellarators, but most magnetically confined plasma devices cannot take advantage of standard ECE diagnostics to measure temperature. They are either overdense, operating at high density relative to the magnetic field (e.g. {omega}{sub pe} >> {Omega}{sub ce} in a spherical torus) or they have insufficient density and temperature to reach the blackbody condition ({tau} > 2). Electron Bernstein waves (EBWs) are electrostatic waves which can propagate in overdense plasmas and have a high optical thickness at the electron cyclotron resonance layers, as a result of their large K{sub i}. This talk reports on measurements of EBW emission on the CDX-U spherical torus, where B{sub 0} {approx} 2 kG, {approx} 10{sup 13} cm{sup -3} and T{sub e} {approx} 10 - 200 eV. Results will be presented for both direct detection of EBWs and for mode-converted EBW emission. The EBW emission was absolutely calibrated and compared to the electron temperature profile measured by a multi-point Thomson scattering diagnostic. Depending on the plasma conditions, the mode-converted EBW radiation temperature was found to be {le} T{sub e} and the emission source was determined to be radially localized at the electron cyclotron resonance layer. A Langmuir triple probe was employed to measure changes in edge density profile in the vicinity of the upper hybrid resonance where the mode conversion of the EBWs is expected to occur. Changes in the mode conversion efficiency may explain the observation of mode-converted EBW radiation temperatures below T{sub e}. Initial results suggest EBW emission and EBW heating are viable concepts for plasmas where {omega}{sub pe} >> {Omega}{sub ce}.

  17. Hybrid-structure atomic models for HED laboratory plasma diagnostics and simulations

    Science.gov (United States)

    Hansen, Stephanie

    2010-03-01

    While theoretical atomic physics calculations are well developed for isolated atoms and have been thoroughly benchmarked against low-density laboratory sources such as electron beam ion traps and tokamak plasmas, the high energy density (HED) regime offers significant challenges for atomic physics and spectroscopic modeling. High plasma densities lead to collective effects such as continuum lowering, line broadening, and significant populations in multiply excited atomic states. These effects change the plasma equation of state and the character of emission and absorption spectra and must be accounted for in order to accurately simulate radiative transfer in and apply spectroscopic diagnostics to HED plasmas. Modeling complex mid- and high-Z ions in the HED regime is a particular challenge because exponential growth in accessible configuration space overwhelms the reduction of the Rydberg levels through continuum lowering. This talk will discuss one approach to generating a tractable spectroscopic-quality atomic kinetics model and describe its application to HED laboratory plasmas produced on Sandia's Z facility. [4pt] Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  18. Identification and Plasma Diagnostics Study of Extreme Ultraviolet Transitions in Highly Charged Yttrium

    Directory of Open Access Journals (Sweden)

    Roshani Silwal

    2017-09-01

    Full Text Available Extreme ultraviolet spectra of the L-shell ions of highly charged yttrium (Y 26 + –Y 36 + were observed in the electron beam ion trap of the National Institute of Standards and Technology using a flat-field grazing-incidence spectrometer in the wavelength range of 4 nm-20 nm. The electron beam energy was systematically varied from 2.3 keV–6.0 keV to selectively produce different ionization stages. Fifty-nine spectral lines corresponding to Δ n = 0 transitions within the n = 2 and n = 3 shells have been identified using detailed collisional-radiative (CR modeling of the non-Maxwellian plasma. The uncertainties of the wavelength determinations ranged between 0.0004 nm and 0.0020 nm. Li-like resonance lines, 2s– 2 p 1 / 2 and 2s–2 p 3 / 2 , and the Na-like D lines, 3s– 3 p 1 / 2 and 3s– 3 p 3 / 2 , have been measured and compared with previous measurements and calculations. Forbidden magnetic dipole (M1 transitions were identified and analyzed for their potential applicability in plasma diagnostics using large-scale CR calculations including approximately 1.5 million transitions. Several line ratios were found to show strong dependence on electron density and, hence, may be implemented in the diagnostics of hot plasmas, in particular in fusion devices.

  19. Cross-diagnostic comparison of fluctuation measurements in a cylindrical argon plasma

    Science.gov (United States)

    Light, Adam; Chakraborty Thakur, Saikat; Tynan, George

    2016-10-01

    The advent of fast imaging diagnostics, which provide two-dimensional measurements on relevant plasma time scales, has proven invaluable for interpreting plasma dynamics in laboratory devices. Despite its success, imaging remains a qualitative aid for many studies, because intensity is difficult to map onto a single physical variable for use in a theoretical model. This work continues our exploration of the relationship between visible-light imaging and other diagnostics in the Controlled Shear Decorrelation Experiment (CSDX). CSDX is a well-characterized linear machine producing dense plasmas relevant to the tokamak edge (Te 5 eV, ne 1013 /cc). Visible light from ArI and ArII line emission is collected at high frame rates using a fast digital camera, floating potential and ion-saturation current are measured by an array of electrostatic probe tips, and average profiles of ion temperature and velocity are obtained using laser-induced fluorescence (LIF). We present a detailed comparison between these measurements, including temporal, spatial, and spectral properties in various operational regimes.

  20. Testing of a pulsed He supersonic beam for plasma edge diagnostic in the TJ-IU torsatron

    Science.gov (United States)

    Tabarés, F. L.; Tafalla, D.; Herrero, V.; Tanarro, I.

    1997-02-01

    A new, compact atomic beam source based on the supersonic expansion of He has been developed for application as a plasma edge diagnostic. The beam is produced from a pulsed valve with a duration between 0.2 to 2 ms and a nominal repetition rate 10 and a divergence of ± 1° have been achieved at stagnation pressures below 2 bar. The diagnostic has been tested in ECRH plasmas on the TJ-IU torsatron, representing the first application of a supersonic beam to plasma characterization, to our knowledge. Operational conditions which minimized the total amount of He injected into the plasma were chosen. Non-perturbative injection conditions in the low density plasmas could be obtained at local He densities of ⋍ 1 × 10 11 cm -3 and a beam diameter < 1 cm. Due to the relatively low electron density of the ECRH plasmas, and to the good penetration characteristics of the supersonic He beam, the diagnostic could be used up to fairly low values of the normalized plasma minor radius, {r}/{a} (a = 12 cm) . Details of the optimization of the atomic beam diagnostics and typical results for steady state conditions in the TJ-IU plasmas are presented.

  1. Testing of a pulsed He supersonic beam for plasma edge diagnostic in the TJ-IU torsatron

    Energy Technology Data Exchange (ETDEWEB)

    Tabares, F.L. [Association EURATOM/CIEMAT, Madrid (Spain); Tafalla, D. [Association EURATOM/CIEMAT, Madrid (Spain); Herrero, V. [Instituto de Estructura de la Materia, CSIC, 28006 Madrid (Spain); Tanarro, I. [Instituto de Estructura de la Materia, CSIC, 28006 Madrid (Spain)

    1997-02-01

    A new, compact atomic beam source based on the supersonic expansion of He has been developed for application as a plasma edge diagnostic. The beam is produced from a pulsed valve with a duration between 0.2 to 2 ms and a nominal repetition rate <500 Hz. A terminal speed ratio >10 and a divergence of {+-}1 have been achieved at stagnation pressures below 2 bar. The diagnostic has been tested in ECRH plasmas on the TJ-IU torsatron, representing the first application of a supersonic beam to plasma characterization, to our knowledge. Operational conditions which minimized the total amount of He injected into the plasma were chosen. Non-perturbative injection conditions in the low density plasmas could be obtained at local He densities of {approx_equal}1 x 10{sup 11} cm{sup -3} and a beam diameter <1 cm. Due to the relatively low electron density of the ECRH plasmas, and to the good penetration characteristics of the supersonic He beam, the diagnostic could be used up to fairly low values of the normalized plasma minor radius, r/a (a=12 cm). Details of the optimization of the atomic beam diagnostics and typical results for steady state conditions in the TJ-IU plasmas are presented. (orig.).

  2. Influence of excited state spatial distributions on plasma diagnostics: Atmospheric pressure laser-induced He-H2 plasma

    Science.gov (United States)

    Monfared, Shabnam K.; Hüwel, Lutz

    2012-10-01

    Atmospheric pressure plasmas in helium-hydrogen mixtures with H2 molar concentrations ranging from 0.13% to 19.7% were investigated at times from 1 to 25 μs after formation by a Q-switched Nd:YAG laser. Spatially integrated electron density values are obtained using time resolved optical emission spectroscopic techniques. Depending on mixture concentration and delay time, electron densities vary from almost 1017 cm-3 to about 1014 cm-3. Helium based results agree reasonably well with each other, as do values extracted from the Hα and Hβ emission lines. However, in particular for delays up to about 7 μs and in mixtures with less than 1% hydrogen, large discrepancies are observed between results obtained from the two species. Differences decrease with increasing hydrogen partial pressure and/or increasing delay time. In mixtures with molecular hydrogen fraction of 7% or more, all methods yield electron densities that are in good agreement. These findings seemingly contradict the well-established idea that addition of small amounts of hydrogen for diagnostic purposes does not perturb the plasma. Using Abel inversion analysis of the experimental data and a semi-empirical numerical model, we demonstrate that the major part of the detected discrepancies can be traced to differences in the spatial distributions of excited helium and hydrogen neutrals. The model yields spatially resolved emission intensities and electron density profiles that are in qualitative agreement with experiment. For the test case of a 1% H2 mixture at 5 μs delay, our model suggests that high electron temperatures cause an elevated degree of ionization and thus a reduction of excited hydrogen concentration relative to that of helium near the plasma center. As a result, spatially integrated analysis of hydrogen emission lines leads to oversampling of the plasma perimeter and thus to lower electron density values compared to those obtained from helium lines.

  3. A diagnostic system for electrical faults in a high current discharge plasma setup.

    Science.gov (United States)

    Nigam, S; Aneesh, K; Navathe, C P; Gupta, P D

    2011-02-01

    A diagnostic system to detect electrical faults inside a coaxial high current discharge device is presented here. This technique utilizes two biconical antennas picking up electromagnetic radiation from the discharge device, a voltage divider sensing input voltage, and a Rogowski coil measuring the main discharge current. A computer program then analyses frequency components in these signals and provides information as to whether the discharge event was normal or any breakdown fault occurred inside the coaxial device. The diagnostic system is developed for a 450 kV and 50 kA capillary discharge plasma setup. For the setup various possible faults are analyzed by electrical simulation, followed by experimental results. In the case of normal discharge through the capillary load the dominant frequency is ∼4 MHz. Under faulty conditions, the peak in magnitude versus frequency plot of the antenna signal changes according to the fault position which involves different paths causing variation in the equivalent circuit elements.

  4. Additive Manufacture (3D Printing) of Plasma Diagnostic Components and Assemblies for Fusion Experiments

    Science.gov (United States)

    Quinley, Morgan; Chun, Katherine; Melnik, Paul; Sieck, Paul; Smith, Trevor; Stuber, James; Woodruff, Simon; Romero-Talamas, Carlos; Rivera, William; Card, Alexander

    2016-10-01

    We are investigating the potential impact of additive manufacturing (3D printing) on the cost and complexity of plasma diagnostics. We present a survey of the current state-of-the-art in additive manufacture of metals, as well as the design of diagnostic components that have been optimized for and take advantage of these processes. Included among these is a set of retarding field analyzer probe heads that have been printed in tungsten with internal heat sinks and cooling channels. Finite element analysis of these probe heads shows the potential for a 750K reduction in peak temperature, allowing the probe to take data twice as often without melting. Results of the evaluation of these probe heads for mechanical strength and outgassing, as well as their use on Alcator C-Mod will be presented. Supported by DOE SBIR Grant DE-SC0011858.

  5. A diagnostic system for electrical faults in a high current discharge plasma setup

    Science.gov (United States)

    Nigam, S.; Aneesh, K.; Navathe, C. P.; Gupta, P. D.

    2011-02-01

    A diagnostic system to detect electrical faults inside a coaxial high current discharge device is presented here. This technique utilizes two biconical antennas picking up electromagnetic radiation from the discharge device, a voltage divider sensing input voltage, and a Rogowski coil measuring the main discharge current. A computer program then analyses frequency components in these signals and provides information as to whether the discharge event was normal or any breakdown fault occurred inside the coaxial device. The diagnostic system is developed for a 450 kV and 50 kA capillary discharge plasma setup. For the setup various possible faults are analyzed by electrical simulation, followed by experimental results. In the case of normal discharge through the capillary load the dominant frequency is ˜4 MHz. Under faulty conditions, the peak in magnitude versus frequency plot of the antenna signal changes according to the fault position which involves different paths causing variation in the equivalent circuit elements.

  6. Analysis and Interpretation of the Plasma Dynamic Response to Additional Heating Power using different Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Manini, A

    2002-07-01

    The main goal in the research of nuclear fusion, and therefore in tokamak research as well, is the development of a high power, steady-state power plant. To obtain the high power required for igniting the plasma, the size of the device must be very large. The performance of the tokamak plasma depends in particular on the plasma shape and on the internal plasma profiles. These profiles include those of the current density and the pressure, two quantities that can be modified by means of auxiliary heating methods such as Electron Cyclotron Heating (ECH). ECH is a very important tool due to its capability of injecting highly localised and intense power. Off-axis ECH and Electron Cyclotron Current Drive (ECCD) modify both current density and electron temperature profiles, leading to modification of confinement and stability properties. in particular, complete stabilisation of magnetohydrodynamic modes using ECCD is feasible. Furthermore, ECH is crucial as a mean of increasing the bootstrap current fraction through the formation of internal transport barriers, so that confinement is also improved. Finally, it is also noted that modulated ECH (MECH) is a very effective tool for perturbative energy transport experiments in many different regimes. Experiments performed in the TCV and the ASDEX Upgrade tokamaks are presented. The role of TCV is very important due to its flexibility of varying the plasma shape, its versatile high power ECH system at both the second and third electron cyclotron harmonics, and due to the numerous diagnostics installed, e.g. the two soft X-ray (SXR) diagnostics which simultaneously allow high temporal and spatial resolutions. The importance of ASDEX Upgrade is related to its large size, which makes it a reactor-relevant experimental facility, and to the Neutral Beam Injection (NBI) and ECH heating facilities, which allow a study of heat and particle transport in either mostly ion-heated or mostly electron-heated regimes. Moreover, for the

  7. Serial data acquisition for the X-ray plasma diagnostics with selected GEM detector structures

    Science.gov (United States)

    Czarski, T.; Chernyshova, M.; Pozniak, K. T.; Kasprowicz, G.; Zabolotny, W.; Kolasinski, P.; Krawczyk, R.; Wojenski, A.; Zienkiewicz, P.

    2015-10-01

    The measurement system based on GEM—Gas Electron Multiplier detector is developed for X-ray diagnostics of magnetic confinement tokamak plasmas. The paper is focused on the measurement subject and describes the fundamental data processing to obtain reliable characteristics (histograms) useful for physicists. The required data processing have two steps: 1—processing in the time domain, i.e. events selections for bunches of coinciding clusters, 2—processing in the planar space domain, i.e. cluster identification for the given detector structure. So, it is the software part of the project between the electronic hardware and physics applications. The whole project is original and it was developed by the paper authors. The previous version based on 1-D GEM detector was applied for the high-resolution X-ray crystal spectrometer KX1 in the JET tokamak. The current version considers 2-D detector structures for the new data acquisition system. The fast and accurate mode of data acquisition implemented in the hardware in real time can be applied for the dynamic plasma diagnostics. Several detector structures with single-pixel sensors and multi-pixel (directional) sensors are considered for two-dimensional X-ray imaging. Final data processing is presented by histograms for selected range of position, time interval and cluster charge values. Exemplary radiation source properties are measured by the basic cumulative characteristics: the cluster position distribution and cluster charge value distribution corresponding to the energy spectra. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  8. Spectroscopic diagnostics of superthermal electrons with high-number harmonic EC radiation in tokamak reactor plasmas

    Directory of Open Access Journals (Sweden)

    Minashin P.V.

    2015-01-01

    Full Text Available A method of spectroscopic diagnostics of the average perpendicular-to-magnetic-field momentum of the superthermal component of the electron velocity distribution (EVD, based on the high-number-harmonic electron cyclotron (EC radiation, is suggested for nuclear fusion-reactor plasmas under condition of a strong auxiliary heating (e.g. in tokamak DEMO, a next step after tokamak ITER. The method is based on solving an inverse problem for reconstruction of the EVD in parallel and perpendicular-to-magnetic-field components of electron momentum at high and moderate energies responsible for the emission of the high-number-harmonic EC radiation.

  9. Cell-free DNA promoter hypermethylation in plasma as a diagnostic marker for pancreatic adenocarcinoma

    DEFF Research Database (Denmark)

    Henriksen, Stine Dam; Madsen, Poul Henning; Larsen, Anders Christian;

    2016-01-01

    analysis using backward stepwise elimination. RESULTS: Patients with pancreatic adenocarcinoma (n = 95), chronic pancreatitis (n = 97) and acute pancreatitis (n = 59) and patients screened, but negative for pancreatic adenocarcinoma (n = 27), were included. The difference in mean number of methylated genes...... with chronic/acute pancreatitis were included as additional benign control groups. Based on an optimized accelerated bisulfite treatment protocol, methylation-specific PCR of a 28 gene panel was performed on plasma samples. A diagnostic prediction model was developed by multivariable logistic regression...

  10. Investigation of relativistic laser-plasmas using nuclear diagnostics; Untersuchung relativistischer Laserplasmen mittels nukleardiagnostischer Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, Marc M.

    2011-01-19

    The present work explores with the development of a novel nuclear diagnostic method for the investigation of the electron dynamics in relativistic laser-plasma interactions. An additional aim of this work was the determination of the real laser peak intensity via the interaction of an intense laser short-pulse with a solid target. The nuclear diagnostics is based on a photo-neutron disintegration nuclear activation method. The main constituent of the nuclear diagnostic are novel pseudoalloic activation targets as a kind of calorimeter to measure the high-energy bremsstrahlung produced by relativistic electrons. The targets are composed of several stable isotopes with different ({gamma},xn)-reaction thresholds. The activated nuclides were identified via the characteristic gamma-ray decay spectrum by using high-resolution gamma spectroscopy after the laser irradiation. Via the gamma spectroscopy the ({gamma},xn)-reaction yields were determined. The high-energy bremsstrahlung spectrum has been deconvolved using a novel analysis method based on a modified Penfold-Leiss method. This facilitates the reconstruction of the spectrum of bremsstrahlung photons without any anticipated fit procedures. Furthermore, the characterization of the corresponding bremsstrahlung electrons in the interaction zone is accessible immediately. The consolidated findings about the properties of the relativistic electrons were used to determine the real peak intensity at the laser-plasma interaction zone. In the context of this work, experiments were performed at three different laser facilities. First Experiments were carried out at the 100 TW laser facility at Laboratoire pour l'Utilisation des Lasers Intense (LULI) in France and supplementary at the Vulcan laser facility at Rutherford Appleton Laboratory (RAL) in United Kingdom. The main part of the activation experiments were performed at the PHELIX laser facility (Petawatt High Energy Laser for heavy Ion EXperiments) at GSI

  11. Reproducible diagnostic metabolites in plasma from typhoid fever patients in Asia and Africa.

    Science.gov (United States)

    Näsström, Elin; Parry, Christopher M; Vu Thieu, Nga Tran; Maude, Rapeephan R; de Jong, Hanna K; Fukushima, Masako; Rzhepishevska, Olena; Marks, Florian; Panzner, Ursula; Im, Justin; Jeon, Hyonjin; Park, Seeun; Chaudhury, Zabeen; Ghose, Aniruddha; Samad, Rasheda; Van, Tan Trinh; Johansson, Anders; Dondorp, Arjen M; Thwaites, Guy E; Faiz, Abul; Antti, Henrik; Baker, Stephen

    2017-05-09

    Salmonella Typhi is the causative agent of typhoid. Typhoid is diagnosed by blood culture, a method that lacks sensitivity, portability and speed. We have previously shown that specific metabolomic profiles can be detected in the blood of typhoid patients from Nepal (Näsström et al., 2014). Here, we performed mass spectrometry on plasma from Bangladeshi and Senegalese patients with culture confirmed typhoid fever, clinically suspected typhoid, and other febrile diseases including malaria. After applying supervised pattern recognition modelling, we could significantly distinguish metabolite profiles in plasma from the culture confirmed typhoid patients. After comparing the direction of change and degree of multivariate significance, we identified 24 metabolites that were consistently up- or down regulated in a further Bangladeshi/Senegalese validation cohort, and the Nepali cohort from our previous work. We have identified and validated a metabolite panel that can distinguish typhoid from other febrile diseases, providing a new approach for typhoid diagnostics.

  12. Ion Source for Neutral beam injection meant for plasma and magnetic field diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Vainionpaa, Jaakko Hannes; Leung, Ka Ngo; Gough, Richard A.; Kwan, Joe W.; Levinton, Fred

    2007-06-01

    At the Lawrence Berkeley National Laboratory (LBNL) a diagnostic neutral beam injection system for measuring plasma parameters, flow velocity, and local magnetic field is being developed. The systems is designed to have a 90 % proton fraction and small divergence with beam current at 5-6 A and a pulse length of {approx}1 s occurring once every 1-2 min. The ion source needs to generate uniform plasma over a large (8 cm x 5 cm) extraction area. For this application, we have compared RF driven multicusp ion sources operating with either an external or an internal antenna in similar ion source geometry. The ion beam will be made of an array of six sheet-shaped beamlets. The design is optimized using computer simulation programs.

  13. Analysis and Interpretation of the Plasma Dynamic Response to Additional Heating Power using different Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Manini, A

    2002-07-01

    The main goal in the research of nuclear fusion, and therefore in tokamak research as well, is the development of a high power, steady-state power plant. To obtain the high power required for igniting the plasma, the size of the device must be very large. The performance of the tokamak plasma depends in particular on the plasma shape and on the internal plasma profiles. These profiles include those of the current density and the pressure, two quantities that can be modified by means of auxiliary heating methods such as Electron Cyclotron Heating (ECH). ECH is a very important tool due to its capability of injecting highly localised and intense power. Off-axis ECH and Electron Cyclotron Current Drive (ECCD) modify both current density and electron temperature profiles, leading to modification of confinement and stability properties. in particular, complete stabilisation of magnetohydrodynamic modes using ECCD is feasible. Furthermore, ECH is crucial as a mean of increasing the bootstrap current fraction through the formation of internal transport barriers, so that confinement is also improved. Finally, it is also noted that modulated ECH (MECH) is a very effective tool for perturbative energy transport experiments in many different regimes. Experiments performed in the TCV and the ASDEX Upgrade tokamaks are presented. The role of TCV is very important due to its flexibility of varying the plasma shape, its versatile high power ECH system at both the second and third electron cyclotron harmonics, and due to the numerous diagnostics installed, e.g. the two soft X-ray (SXR) diagnostics which simultaneously allow high temporal and spatial resolutions. The importance of ASDEX Upgrade is related to its large size, which makes it a reactor-relevant experimental facility, and to the Neutral Beam Injection (NBI) and ECH heating facilities, which allow a study of heat and particle transport in either mostly ion-heated or mostly electron-heated regimes. Moreover, for the

  14. Drifting plasma collection by a positive biased tether wire in LEO-like plasma conditions: current measurement and plasma diagnostic

    OpenAIRE

    Siguier, Jean-Michel; Sarrailh, Pierre; Roussel, Jean-François; Inguimbert, Virgine; Murat, Gaël; Sanmartín Losada, Juan Ramón

    2013-01-01

    BETs is a three-year project financed by the Space Program of the European Commission, aimed at developing an efficient deorbit system that could be carried on board any future satellite launched into Low Earth Orbit (LEO). The operational system involves a conductive tape-tether left bare to establish anodic contact with the ambient plasma as a giant Langmuir probe. As a part of this project, we are carrying out both numerical and experimental approaches to estimate the collected current by ...

  15. Diagnostic suite of the C-2U advanced beam-driven field-reversed configuration plasma experiment

    Science.gov (United States)

    Thompson, M. C.; Gota, H.; Putvinski, S.; Tuszewski, M.; Binderbauer, M.

    2016-11-01

    The C-2U experiment at Tri Alpha Energy studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes magnetic sensors, interferometry, Thomson scattering, spectroscopy, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors. While many of these diagnostic systems were inherited from the preceding experiment C-2, C-2U has a variety of new and upgraded diagnostic systems: multi-chord far-infrared polarimetry, multiple fast imaging cameras with selectable atomic line filters, proton detector arrays, and 100 channel bolometer units capable of observing multiple regions of the spectrum simultaneously. In addition, extensive ongoing work focuses on advanced methods of measuring separatrix shape and plasma current profile that will facilitate equilibrium reconstruction and active control of the FRC plasma.

  16. Diagnostic suite of the C-2U advanced beam-driven field-reversed configuration plasma experiment

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, M. C., E-mail: mthompson@trialphaenergy.com; Gota, H.; Putvinski, S.; Tuszewski, M.; Binderbauer, M. [Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States)

    2016-11-15

    The C-2U experiment at Tri Alpha Energy studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes magnetic sensors, interferometry, Thomson scattering, spectroscopy, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors. While many of these diagnostic systems were inherited from the preceding experiment C-2, C-2U has a variety of new and upgraded diagnostic systems: multi-chord far-infrared polarimetry, multiple fast imaging cameras with selectable atomic line filters, proton detector arrays, and 100 channel bolometer units capable of observing multiple regions of the spectrum simultaneously. In addition, extensive ongoing work focuses on advanced methods of measuring separatrix shape and plasma current profile that will facilitate equilibrium reconstruction and active control of the FRC plasma.

  17. Kinetic and Diagnostic Studies of Molecular Plasmas Using Laser Absorption Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Welzel, S [INP-Greifswald, 17489 Greifswald, Felix-Hausdorff-Str. 2 (Germany); Rousseau, A [Laboratoire de Physique et Technologie des Plasmas, Ecole Polytechnique, CNRS, 91128 Palaiseau (France); Davies, P B [Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW (United Kingdom); Roepcke, J [INP-Greifswald, 17489 Greifswald, Felix-Hausdorff-Str. 2 (Germany)

    2007-10-15

    Within the last decade mid infrared absorption spectroscopy between 3 and 20 {mu}m, known as Infrared Laser Absorption Spectroscopy (IRLAS) and based on tuneable semiconductor lasers, namely lead salt diode lasers, often called tuneable diode lasers (TDL), and quantum cascade lasers (QCL) has progressed considerably as a powerful diagnostic technique for in situ studies of the fundamental physics and chemistry of molecular plasmas. The increasing interest in processing plasmas containing hydrocarbons, fluorocarbons, organo-silicon and boron compounds has lead to further applications of IRLAS because most of these compounds and their decomposition products are infrared active. IRLAS provides a means of determining the absolute concentrations of the ground states of stable and transient molecular species, which is of particular importance for the investigation of reaction kinetics. Information about gas temperature and population densities can also be derived from IRLAS measurements. A variety of free radicals and molecular ions have been detected, especially using TDLs. Since plasmas with molecular feed gases are used in many applications such as thin film deposition, semiconductor processing, surface activation and cleaning, and materials and waste treatment, this has stimulated the adaptation of infrared spectroscopic techniques to industrial requirements. The recent development of QCLs offers an attractive new option for the monitoring and control of industrial plasma processes as well as for highly time-resolved studies on the kinetics of plasma processes. The aim of the present article is threefold: (i) to review recent achievements in our understanding of molecular phenomena in plasmas (ii) to report on selected studies of the spectroscopic properties and kinetic behaviour of radicals, and (iii) to describe the current status of advanced instrumentation for TDLAS in the mid infrared.

  18. An Optical Streak Diagnostic for Observing Anode-Cathode Plasmas for Radiographic Source Development

    Energy Technology Data Exchange (ETDEWEB)

    Droemer, Darryl W. [National Security Technologies, LLC; Crain, Marlon D.; Lare, Gregory A. [National Security Technologies, LLC; Bennett, Nichelle L. [National Security Technologies, LLC; Johnston, Mark D. [Sandia National Laboratories

    2013-06-13

    National Security Technologies, LLC, and Sandia National Laboratories are collaborating in the development of pulsed power–driven flash x-ray radiographic sources that utilize high-intensity electron beam diodes. The RITS 6 (Radiographic Integrated Test Stand) accelerator at Sandia is used to drive a self magnetic pinch diode to produce a Bremsstrahlung x-ray source. The high electric fields and current densities associated with these short A-K gap pinch beam diodes present many challenges in diode development. Plasmas generated at both the anode and cathode affect the diode performance, which is manifested in varying spot (source) sizes, total dose output, and impedance profiles. Understanding the nature of these plasmas including closure rates and densities is important in modeling their behavior and providing insight into their mitigation. In this paper we describe a streak camera–based optical diagnostic that is capable of observing and measuring plasma evolution within the A-K gap. By imaging a region of interest onto the input slit of a streak camera, we are able to produce a time-resolved one-dimensional image of the evolving plasma. Typical data are presented.

  19. Plasma-water systems studied with optical diagnostics including sum-frequency generation spectroscopy

    Science.gov (United States)

    Ito, Tsuyohito

    2016-09-01

    Recently, various applications of plasma-water systems have been reported, such as materials synthesis, agricultural applications, and medical treatments. As one of basic studies of such systems, we are investigating water surface structure influenced by a plasma via vibrational sum-frequency generation spectroscopy. Vibrational sum-frequency generation spectroscopy is known to be an interfacially active diagnostic technique, as such process occurs in noncentrosymmetric medium. Visible and wavenumber-tunable infrared beams are simultaneously irradiated to the interface. The interfacial water has ice-like ( 3200 cm-1), liquid-like ( 3400 cm-1), and free OH (3700 cm-1) structures (assignment of the ice-like structure still remains contentious), and the intensity of the signal becomes stronger when the tunable infrared beam resonates with a vibration of the structures. The results indicate that with generating air dielectric barrier discharges for supplying reactive species to the water surface, all investigated signals originating from the above-mentioned three structures decrease. Furthermore, the signal strengths are recovered after terminating the plasma generation. We currently believe that the surface density of the reactive species should be high when they are found at the water surface. Details on the experimental results of the sum-frequency generation spectroscopy, as well as other spectroscopic results of plasma-water systems, will be presented at the conference.

  20. X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics

    Science.gov (United States)

    Rácz, R.; Biri, S.; Pálinkás, J.; Mascali, D.; Castro, G.; Caliri, C.; Romano, F. P.; Gammino, S.

    2016-02-01

    Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago. The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.

  1. Development of the so-called third stage laser Thomson scattering diagnostics of plasmas

    Science.gov (United States)

    Muraoka, Katsunori; Yamagata, Yukihiko; Hisano, Taishi; Uchino, Kiichirou; Miyazaki, Koichi

    2003-10-01

    In the recent review article,^1) we indicated that the incoherent laser Thomson scattering (LTS) diagnostics of plasmas for measurements of electron densities and temperatures (or more generally EEDFs) be classified as having evolved from the first stage where a whole Thomson spectrum be obtained during a single laser pulse from plasmas having electron density of above 10^18 m-3, through the second stage where data accumulation be prerequisite for ne below 10^18 m-3, and to the third stage where a strong suppression of stray light in addition to the data accumulation be necessary to measure at an extremely small size of less than 100 μm near to material surfaces. The third stage LTS was first demonstrated for a PDP (plasma display panel)-like discharge three years ago employing a triple grating polychromator. In order to further expand its applicable ranges, we are pursuing a more general approach by taking into account such factors as laser divergence, stray light suppression and other aspects. The present status is presented. 1) K. Muraoka, K. Uchino, Y. Yamagata, Y. Noguchi, M. Mansour, P. Suanpoot, S. Narishige, and M. Noguchi, Plasma Sources Sci. Technol. 11 (2002) A143.

  2. X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Rácz, R., E-mail: rracz@atomki.hu; Biri, S.; Pálinkás, J. [Institute for Nuclear Research (Atomki), Hungarian Academy of Sciences, Bem tér 18/C, H-4026 Debrecen (Hungary); Mascali, D.; Castro, G.; Caliri, C.; Gammino, S. [Instituto Nazionale di Fisica Nucleare—Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Romano, F. P. [Instituto Nazionale di Fisica Nucleare—Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); CNR, Istituto per i Beni Archeologici e Monumentali, Via Biblioteca 4, 95124 Catania (Italy)

    2016-02-15

    Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago. The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.

  3. X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics.

    Science.gov (United States)

    Rácz, R; Biri, S; Pálinkás, J; Mascali, D; Castro, G; Caliri, C; Romano, F P; Gammino, S

    2016-02-01

    Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago. The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.

  4. Diagnostic systems for the nuclear fusion and plasma research in the PF-24 plasma focus laboratory at the IFJ PAN

    Directory of Open Access Journals (Sweden)

    Marciniak Łukasz

    2016-12-01

    Full Text Available This paper presents a set of diagnostics dedicated to PF-24 - new medium size - plasma focus (PF device built and operated at the Institute of Nuclear Physics Polish Academy of Sciences (IFJ PAN. The PF-24 can operate at energy level up to 93 kJ and charging voltage up to 40 kV. Each condenser is connected with a specially designed spark gap with a very small jitter, which ensures a high effi ciency and a low current rise time. The working parameters of PF-24 generator make it a suitable tool for testing new detection systems to be used in fusion research. Four types of such detection systems are presented in this article: three diagnostic systems used to measure electric quantities (Rogowski coil, magnetic probe, capacitance probe, neutron counter based on beryllium activation, fast neutron pinhole camera based on small-area BCF-12 plastic scintillation detectors and high-speed four-frame soft X-ray camera with microchannel plate.

  5. Development of diffractive XUV-VUV light extractors for fusion plasma diagnostic

    Science.gov (United States)

    Stutman, D.; Caravelli, G.; Delgado-Aparicio, L.; Finkenthal, M.; Tritz, K.; Kaita, R.; Roquemore, L.

    2009-11-01

    The diagnostic and control of next generation MFE and ICF fusion experiments will require optical light extractors capable of withstanding intense plasma and radiation exposure. A solution applicable from the XUV to the infrared is to use free-standing diffractive optics such as transmission gratings or zone plates. Here we present results on XUV-VUV diffractive extractors for the diagnostic of boundary MFE plasmas. For the VUV range we developed Si transmission gratings having 1 μm period, 5 μm thickness, 40% open fraction, 1x2 mm active area, and coated with Ni, while for the XUV range we use SiN gratings having 0.2 μm period, 0.3 μm thickness, 1x1 mm area, and coated with Ta. The grating extractors are spectrally and spatially calibrated in the laboratory using a newly developed extended XUV-VUV source and will be employed for imaging spectrometry on the NSTX experiment. The operational characteristics of the extended source and first space resolved XUV-VUV spectra will be presented. Work supported by DoE Grant DE-FG02-99ER54523 at JHU and Contract DE-AC02-09CH11466 at PU.

  6. Plasma magnetic field diagnostic using two-photon Doppler-free LIF

    Science.gov (United States)

    Yoon, Young Dae; Bellan, Paul

    2015-11-01

    A detailed description of a new plasma B field diagnostic using Doppler-free two-photon laser-induced fluorescence is presented. The diagnostic is based on a method previously developed in the context of rubidium vapor experiments. Two counter-propagating 393nm diode laser beams are directed into an argon plasma to excite Ar-II ions from 3s2 3p4 4 s4P1 / 2 ⟶ 3s2 3p4 4 p4S3 / 2 ⟶ 3s2 3p4 4 d4P3 / 2 . These levels involve two similar (392.86 and 393.25nm) transition wavelengths, so the two counter-propagating beams effectively cancel out the Doppler effect. The excited ions then decay to the 3s2 3p4 4 p4P1 / 2 level, emitting a 324.98nm line which is to be detected by a photomultiplier tube. The Zeeman splitting -- normally unobservable because of the large Doppler broadening -- of the resultant fluorescence is then to be analyzed, yielding the magnetic field of the particular location. This method is expected to provide a 3-D localized, non-perturbing measurement of magnetic fields. An experimental implementation is currently in progress.

  7. Fourier transform infrared phase-modulated ellipsometry for in situ diagnostics of plasma-surface interactions

    Energy Technology Data Exchange (ETDEWEB)

    Shirafuji, T [International Innovation Center, Kyoto University, Sakyo-ku, Kyoto 606-8501 (Japan); Motomura, H [Department of Electronics, Kyoto University, Nishikyo-ku, Katsura 615-8510 (Japan); Tachibana, K [Department of Electronics, Kyoto University, Nishikyo-ku, Katsura 615-8510 (Japan)

    2004-03-21

    Applicability of Fourier transform infrared (FTIR) spectroscopy to an in situ diagnostics tool of plasma-surface interactions is described. After a brief review of conventional reflection absorption spectroscopy (RAS) and phase-modulated RAS (PMRAS), our FTIR phase-modulated spectroscopic ellipsometry (PMSE) is described in detail. The FTIR PMSE is constructed by insertion of a grid polarizer as an analyser in front of an infrared detector in addition to the conventional set-up of PMRAS. This simple change brings about a higher sensitivity than that of conventional PMRAS, which enables us to detect chemical species generated on (or removed from) the top surface layer during plasma processing. This feature is demonstrated by the fact that our FTIR PMSE can be applied to surface diagnostics during reactive ion etching processes such as for Si, SiO{sub 2}/Si, SiO{sub 2}/Si{sub 3}N{sub 4}, SiO{sub 2}/photo-resist and low-dielectric-constant films. (topical review)

  8. Combined complementary plasma diagnostics to characterize a 2f plasma with additional DC current with conditioning effects at the chamber wall

    Science.gov (United States)

    Klick, Michael; Rothe, Ralf; Baek, Kye Hyun; Lee, Eunwoo

    2016-09-01

    Multiple frequencies and DC current used in a low-pressure plasma rf discharge result in an increased complexity. This needs plasma diagnostics applied, in particular in a plasma process chamber. That is done under manufacturing conditions which restrict the applicable plasma diagnostics to non-invasive methods with small footprint. So plasma chamber parameters, optical emission spectroscopy (OES), and self-excited electron spectroscopy (SEERS) are used to characterize the plasma and to understand chamber wall conditioning effects in an Ar plasma. The parameters are classified according to their origin--the region they are representative for. The center ion density is estimated from the DC current and compared to the SEERS electron density reflecting the electron density close to that at the chamber wall. The conditioning effects are caused by Si sputtering at a Si wafer changing the chamber wall state only when the chamber is clean, subsequent plasmas in the same chamber are not affected in that way. Through the combination of the complementary methods it can be shown that the chamber wall condition finally changes the radial plasma density distribution. Also the heating of electrons in the sheath is shown to be influenced by conditioning effects.

  9. Advanced beam dynamics and diagnostics concepts for laser-plasma accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Dornmair, Irene

    2017-05-15

    Laser-Plasma Accelerators (LPAs) combine a multitude of unique features, which makes them very attractive as drivers for next generation brilliant light sources including compact X-ray free-electron lasers. They provide high accelerating gradients, thereby drastically shrinking the accelerator size, while at the same time the produced electron bunches are intrinsically as short as a few femtoseconds and carry high peak currents. LPA are subject of very active research, yet, the field currently faces the challenge of improving the beam quality, and achieving stable and well-controlled injection and acceleration. This thesis tackles this issue from three different sides. A novellongitudinal phase space diagnostics is proposed that employs the strong fields present in plasma wakefields to streak ultrashort electron bunches. This allows for a temporal resolution down to the attosecond range, enabling direct determination to the current profile and the slice energy spread, both crucial quantities for the performance of free-electron lasers. Furthermore, adiabatic matching sections at the plasma-vacuum boundary are investigated. These can drastically reduce the beam divergence and thereby relax the constraints on the subsequent beam optics. For externally injected beams, the matching sections could even provide the key technology that permits emittance conservation by increasing the matched beam size to a level achievable with currently available magnetic optics. Finally, a new method is studied that allows to modify the wakefield shape. To this end, the plasma density is periodically modulated. One possible application can be to remove the linearly correlated energy spread, or chirp, from the accelerated bunch, which is suspected of being responsible for the main part of the often large energy spread of plasma accelerated beams.

  10. Application of mid-infrared tuneable diode laser absorption spectroscopy to plasma diagnostics: a review

    Energy Technology Data Exchange (ETDEWEB)

    Roepcke, J [INP-Greifswald, 17489 Greifswald, Friedrich-Ludwig-Jahn-Str. 19 (Germany); Lombardi, G [CNRS LIMHP, Universite Paris XIII, 99, av. J.B. Clement, 93430 Villetaneuse (France); Rousseau, A [Laboratoire de Physique et Technologie des Plasmas, Ecole Polytechnique, CNRS, 91128 Palaiseau (France); Davies, P B [Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW (United Kingdom)

    2006-11-01

    Within the last decade mid-infrared absorption spectroscopy over a region from 3 to 17{mu}m and based on tuneable lead salt diode lasers, often called tuneable diode laser absorption spectroscopy or TDLAS, has progressed considerably as a powerful diagnostic technique for in situ studies of the fundamental physics and chemistry in molecular plasmas. The increasing interest in processing plasmas containing hydrocarbons, fluorocarbons, organo-silicon and boron compounds has led to further applications of TDLAS because most of these compounds and their decomposition products are infrared active. TDLAS provides a means of determining the absolute concentrations of the ground states of stable and transient molecular species, which is of particular importance for the investigation of reaction kinetic phenomena. Information about gas temperature and population densities can also be derived from TDLAS measurements. A variety of free radicals and molecular ions have been detected by TDLAS. Since plasmas with molecular feed gases are used in many applications such as thin film deposition, semiconductor processing, surface activation and cleaning, and materials and waste treatment, this has stimulated the adaptation of infrared spectroscopic techniques to industrial requirements. The recent development of quantum cascade lasers (QCLs) offers an attractive new option for the monitoring and control of industrial plasma processes. The aim of the present paper is threefold: (i) to review recent achievements in our understanding of molecular phenomena in plasmas (ii) to report on selected studies of the spectroscopic properties and kinetic behaviour of radicals and (iii) to describe the current status of advanced instrumentation for TDLAS in the mid-infrared.

  11. Magnetic diagnostics: general principles and the problem of reconstruction of plasma current and pressure profiles in toroidal systems

    Energy Technology Data Exchange (ETDEWEB)

    Pustovitov, V.D.

    2000-04-01

    The restrictions of the magnetic diagnostics are discussed. Being related to the integral nature of the measurable quantities, they follow from the fundamental laws of electromagnetism. A series of particular examples demonstrating the strength of these restrictions is given and analyzed. A general rule is emphasized that the information obtained from external magnetic measurements is obviously insufficient for the reliable evaluation of plasma current and pressure profiles in tokamaks or in stellarators. The underlying reason is that outside the plasma the own field of the equilibrium plasma currents is determined by the boundary conditions on the plasma surface only. (author)

  12. Ion acceleration from intense laser-generated plasma: methods, diagnostics and possible applications

    Directory of Open Access Journals (Sweden)

    Torrisi Lorenzo

    2015-06-01

    Full Text Available Many parameters of non-equilibrium plasma generated by high intensity and fast lasers depend on the pulse intensity and the laser wavelength. In conditions favourable for the target normal sheath acceleration (TNSA regime the ion acceleration from the rear side of the target can be enhanced by increasing the thin foil absorbance through the use of nanoparticles and nanostructures promoting the surface plasmon resonance effect. In conditions favourable for the backward plasma acceleration (BPA regime, when thick targets are used, a special role is played by the laser focal position with respect to the target surface, a proper choice of which may result in induced self-focusing effects and non-linear acceleration enhancement. SiC detectors employed in the time-of-flight (TOF configuration and a Thomson parabola spectrometer permit on-line diagnostics of the ion streams emitted at high kinetic energies. The target composition and geometry, apart from the laser parameters and to the irradiation conditions, allow further control of the plasma characteristics and can be varied by using advanced targets to reach the maximum ion acceleration. Measurements using advanced targets with enhanced the laser absorption effect in thin films are presented. Applications of accelerated ions in the field of ion source, hadrontherapy and nuclear physics are discussed.

  13. Ion Current Collection Diagnostic for the Triggered Plasma Opening Switch Experiment

    Science.gov (United States)

    Jackson, D. P.; Gilmore, M. A.

    2005-10-01

    The novel Triggered Plasma Opening Switch (TPOS) is a unique device that exploits the high conductivity and low mass properties of plasma. The TPOS's objective is to take the initial ˜.8 MA (˜250 ns rise time) storage inductor current and deliver ˜.5 MA at ˜2.5 MV (˜10ns rise time) to a load of ˜5-10 φ. Study of the TPOS characteristics is in progress via an Ion Current Collection Diagnostic (ICCD). The ICCD has been designed, fabricated, tested, and is in use on the TPOS in order to explore the main switch opening profile. The ICCD utilizes 12 charge collectors (biased faraday cups) that are positioned perpendicularly to the main switch stage in order to collect radially traveling ions emitted from the plasma surface via the Child-Langmuir law. Magnetostatic simulations with self consistent space charge emitting surfaces of the main switch using the Trak static 2D finite element code have been conducted as well. Finally, ICCD experimental data have been recorded, and hopefully these data will provide evidence that support both theory and simulation.

  14. Schlieren, Phase-Contrast, and Spectroscopy Diagnostics for the LBNL HIF Plasma Channel Experiment

    Science.gov (United States)

    Ponce, D. M.; Niemann, C.; Fessenden, T. J.; Leemans, W.; Vandersloot, K.; Dahlbacka, G.; Yu, S. S.; Sharp, W. M.; Tauschwitz, A.

    1999-11-01

    The LBNL Plasma Channel experiment has demonstrated stable 42-cm Z-pinch discharge plasma channels with peak currents in excess of 50 kA for a 7 torr nitrogen, 30 kV discharge. These channels offer the possibility of transporting heavy-ion beams for inertial fusion. We postulate that the stability of these channels resides in the existance of a neutral-gas density depresion created by a pre-pulse discharge before the main capacitor bank discharge is created. Here, we present the results and experimental diagnostics setup used for the study of the pre-pulse and main bank channels. Observation of both the plasma and neutral gas dynamics is achieved. Schlieren, Zernike's phase-contrast, and spectroscopic techniques are used. Preliminary Schlieren results show a gas shockwave moving radially at a rate of ≈ 10^6 mm/sec as a result of the fast and localized deposited energy during the evolution of the pre-pulse channel. This data will be used to validate simulation codes (BUCKY and CYCLOPS).

  15. Spectroscropy of middle charge state high-z ions in the ultraviolet for plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Utter, Steven Bryan [Auburn Univ., AL (United States)

    1999-12-11

    The quest for the creation of an economically feasible thermonuclear fusion energy reactor is sttill active after many decades of research. Modern machines produce plasmas which are both hotter and more dense than those created 30 years ago and future devices promise to continue this trend. Paramount to this research is the capability to adequately measure certain parameters of the plasma such as temperature, density, impurity concentration and radiation loss. This dissertation reports three sets of spectroscopic measurements from intermediate charge state of high-Z ions, which have been performed at the Electron Beam Ion Trap (EBIT) facility of the Lawrence Livermore National Laboratory, relevant to the development of spectral plasma diagnostics and to the understanding of radiative energy loss from heavy impurity ions of today's and future fusion devices: measurements of W radiation from 40 - 85 A, precision measurements along the Cu isoelectric sequence, and UV spectroscopy of Ti-like W. The results are also compared to the best available theoretical calculations.

  16. Heavy ion beam probing—diagnostics to study potential and turbulence in toroidal plasmas

    Science.gov (United States)

    Melnikov, A. V.; Krupnik, L. I.; Eliseev, L. G.; Barcala, J. M.; Bravo, A.; Chmyga, A. A.; Deshko, G. N.; Drabinskij, M. A.; Hidalgo, C.; Khabanov, P. O.; Khrebtov, S. M.; Kharchev, N. K.; Komarov, A. D.; Kozachek, A. S.; Lopez, J.; Lysenko, S. E.; Martin, G.; Molinero, A.; de Pablos, J. L.; Soleto, A.; Ufimtsev, M. V.; Zenin, V. N.; Zhezhera, A. I.; T-10 Team; TJ-II Team

    2017-07-01

    Heavy ion beam probing (HIBP) is a unique diagnostics to study the core plasma potential and turbulence. Advanced HIBPs operate in the T-10 tokamak and TJ-II flexible heliac with fine focused (magnetic configurations with ECR and neutral beam injection (NBI) heating at TJ-II. Time evolution of the radial profiles and/or local values of plasma parameters from high field side (HFS) to low field side (LFS), -1  magnetic field B pol (by the beam toroidal shift), poloidal electric filed E pol that allows one to derive the electrostatic turbulent particle flux ΓE×B. The cross-phase of density oscillations produces the phase velocity of their poloidal propagation or rotation; also it gives the poloidal mode number. Dual HIBP, consisting of two identical HIBPs located ¼ torus apart provide the long-range correlations of core plasma parameters. Low-noise high-gain electronics allows us to study broadband turbulence and quasi-coherent modes like geodesic acoustic modes and Alfvén eigenmodes.

  17. Qualifying plasma diagnostics for a high power microwave background of ECRH heated discharges

    Energy Technology Data Exchange (ETDEWEB)

    Hirsch, M.; Baldzuhn, J.; Endler, M.; Laux, M.; Zhang, D.; Laqua, H.P.; Noke, F.; Purps, F.; Ewert, K. [Max-Planck Institut fur Plasmaphysik, EURATOM Association, D-17491 Greifswald (Germany); Oosterbeek, J.W. [Technische Universiteit Eindhoven, Den Doelch 2, 5612 AZ Eindhoven (Netherlands); Jimenez, R. [Associacion EURATOM/CIEMAT, av. Complutense 22, 28040, Madrid (Spain)

    2011-07-01

    Microwave background radiation resulting from multiple reflected unabsorbed ECRH / ECCD power may cause severe problems for microwave absorbing in-vessel components such as gaskets, bellows, windows, isolators and cable insulations in particular during long pulse operation. For qualifying in-vessel components of W7-X in the environment of an isotropic 140 GHz radiation the Microwave Stray Radiation Launch facility, MISTRAL is operated at IPP. Power flux densities of 10-40 kW/m{sup 2} are obtained with a pulsed power gyrotron launching the microwave via a corrugated transmission line and a vacuum window to the MISTRAL vessel. The focus of the program was on cable isolations as required e.g. for in-vessel magnetic diagnostics. Sufficient shielding is obtained in nearly closed metal pipes only. Cryo pumps require a temperature < 12 K where Hydrogen desorption starts. The cryo pumps are usually shielded from plasma radiation by so called chevron structures. It is investigated whether coating of these chevrons with a microwave absorbing layer yields a sufficient reduction of the stray radiation level to ensure cryo pump operation. Diagnostic windows have been tested also. Although the temperature rise even of uncooled ZnSe and quartz windows at 10 kW/m{sup 2} is uncritical with respect to damage the associated refractive index changes may be too high for some diagnostic purposes e.g. for interferometry. A possible shielding are meshes or {mu}W absorbing coatings. Integrated diagnostic mock-ups such as for the diamagnetic loop, the inner Rogowski coils, Mirnov coils and the bolometer head also have been tested

  18. Spectroscopic Investigations of Highly Charged Tungsten Ions - Atomic Spectroscopy and Fusion Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Clementson, Joel [Lund Univ. (Sweden)

    2010-05-01

    The spectra of highly charged tungsten ions have been investigated using x-ray and extreme ultraviolet spectroscopy. These heavy ions are of interest in relativistic atomic structure theory, where high-precision wavelength measurements benchmark theoretical approaches, and in magnetic fusion research, where the ions may serve to diagnose high-temperature plasmas. The work details spectroscopic investigations of highly charged tungsten ions measured at the Livermore electron beam ion trap (EBIT) facility. Here, the EBIT-I and SuperEBIT electron beam ion traps have been employed to create, trap, and excite tungsten ions of M- and L-shell charge states. The emitted spectra have been studied in high resolution using crystal, grating, and x-ray calorimeter spectrometers. In particular, wavelengths of n = 0 M-shell transitions in K-like W55+ through Ne-like W64+, and intershell transitions in Zn-like W44+ through Co-like W47+ have been measured. Special attention is given to the Ni-like W46+ ion, which has two strong electric-dipole forbidden transitions that are of interest for plasma diagnostics. The EBIT measurements are complemented by spectral modeling using the Flexible Atomic Code (FAC), and predictions for tokamak spectra are presented. The L-shell tungsten ions have been studied at electron-beam energies of up to 122 keV and transition energies measured in Ne-like W64+ through Li-like W71+. These spectra constitute the physics basis in the design of the ion-temperature crystal spectrometer for the ITER tokamak. Tungsten particles have furthermore been introduced into the Sustained Spheromak Physics Experiment (SSPX) spheromak in Livermore in order to investigate diagnostic possibilities of extreme ultraviolet tungsten spectra for the ITER divertor. The spheromak measurement and spectral modeling using FAC suggest that tungsten ions in charge states around Er-like W6+ could be useful for

  19. Analytical investigation of microwave resonances of a curling probe for low and high-pressure plasma diagnostics

    Science.gov (United States)

    Arshadi, Ali; Brinkmann, Ralf Peter

    2017-01-01

    The concept of ‘active plasma resonance spectroscopy’ (APRS) has attracted greater interest in recent years as an established plasma diagnostic technique. The APRS describes a class of related methods utilizing the intrinsic ability of plasma to resonate at or near the electron plasma frequency {ω\\text{pe}} . The Curling probe (CP) as a novel realization of the APRS idea, is a miniaturized spiral slot embedded flatly in the chamber wall. Consequently, a plasma diagnostic technique with minimum disturbance and without metal contamination can be developed. To measure the plasma parameters the CP is fed with a weak frequency-swept signal from the exterior of the plasma chamber by a network analyzer which also records the response of the plasma versus the frequency. The resonance behavior is strongly dependent on the electron density and the gas pressure. The CP has also the advantage of resonating at a frequency greater than {ω\\text{pe}} which is dependent on the spiral’s length. The double resonance characteristic gives the CP the ability to be applied in varying plasma regimes. Assuming that the spiralization does not have a considerable effect on the resonances, a ‘straightened’ infinite length CP has recently been investigated (Arshadi and Brinkmann 2016 Plasma Sources Sci. Technol. 25 045014) to obtain the surface wave resonances. This work generalizes the approach and models the CP by a rectangular slot-type resonator located between plasma and quartz. Cold plasma theory and Maxwell’s equations are utilized to compute the electromagnetic fields propagating into the plasma by the diffraction of an incident plane wave at the slot. A mathematical model is employed and both kinds of resonances are derived. The analytical study of this paper shows good agreement with the numerical results of the probe inventors.

  20. [Mass spectrometry analysis of blood plasma lipidome as method of disease diagnostics, evuation of effectiveness and optimization of drug therapy].

    Science.gov (United States)

    Lokhov, P G; Maslov, D L; Balashova, E E; Trifonova, O P; Medvedeva, N V; Torkhovskaya, T I; Ipatova, O M; Archakov, A I; Malyshev, P P; Kukharchuk, V V; Shestakova, E A; Shestakova, M V; Dedov, I I

    2015-01-01

    A new method for the analysis of blood lipid based on direct mass spectrometry of lipophilic low molecular weight fraction of blood plasma has been considered. Such technique allows quantification of hundreds of various types of lipids and this changes existing concepts on diagnostics of lipid disorders and related diseases. The versatility and quickness of the method significantly simplify its wide use. This method is applicable for diagnostics of atherosclerosis, diabetes, cancer and other diseases. Detalization of plasma lipid composition at the molecular level by means of mass spectrometry allows to assess the effectiveness of therapy and to optimize the drug treatment of cardiovascular diseases by phospholipid preparations.

  1. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    In order to support the operation of ITER and the planned experimental programme an extensive set of plasma and first wall measurements will be required. The number and type of required measurements will be similar to those made on the present-day large tokamaks while the specification of the mea...

  2. Fast, Deep-Record-Length, Fiber-Coupled Photodiode Imaging Array for Plasma Diagnostics

    Science.gov (United States)

    Brockington, Samuel; Case, Andrew; Witherspoon, F. Douglas

    2015-11-01

    HyperV Technologies has been developing an imaging diagnostic comprised of an array of fast, low-cost, long-record-length, fiber-optically-coupled photodiode channels to investigate plasma dynamics and other fast, bright events. By coupling an imaging fiber bundle to a bank of amplified photodiode channels, imagers and streak imagers can be constructed. By interfacing analog photodiode systems directly to commercial analog-to-digital converters and modern memory chips, a scalable solution for 100 to 1000 pixel systems with 14 bit resolution and record-lengths of 128k frames has been developed. HyperV is applying these techniques to construct a prototype 1000 Pixel framing camera with up to 100 Msamples/sec rate and 10 to 14 bit depth. Preliminary experimental results as well as future plans will be discussed. Work supported by USDOE Phase 2 SBIR Grant DE-SC0009492.

  3. X-ray calibration facility for plasma diagnostics of the MégaJoule laser

    Directory of Open Access Journals (Sweden)

    Hubert S.

    2013-11-01

    Full Text Available The Laser MégaJoule (LMJ located at CEA-CESTA will be equipped with x-ray plasma diagnostics using different kinds of x-ray components such as filters, mirrors, crystals, detectors and cameras. To guarantee LMJ measurements, detectors such as x-ray cameras need to be regularly calibrated. An x-ray laboratory is devoted to this task and performs absolute x-ray calibrations for similar x-ray cameras running on Laser Integration Line (LIL. This paper presents the x-ray calibration bench with its x-ray tube based High Energy x-ray Source (HEXS and some calibration results. By mean of an ingenious transposition system under vacuum absolute x-ray calibration of x-ray cameras, like streak and stripline ones, can be carried out. Coupled to a new collimation system with micrometric accuracy on aperture sensitivity quantum efficiency measurements can be achieved with reduced uncertainties.

  4. Single-crystal Diamond Detector for DT and DD plasmas diagnostic

    Science.gov (United States)

    Rebai, M.; Cazzaniga, C.; Tardocchi, M.; Grosso, G.; Croci, G.; Perelli Cippo, E.; Calvani, P.; Girolami, M.; Trucchi, D. M.; Gorini, G.

    2016-11-01

    Single-crystal Diamond Detectors (SDD) are good candidates as high-energy neutron detectors in the extreme conditions of the next generation thermonuclear fusion facilities like the ITER experiment, due to their high radiation hardness, fast response time and small size. Neutron detection in SDDs is based on the collection of electron-hole pairs produced by charged particles generated by neutron interaction on 12 C . In this work the SDD response to neutrons with energies between 2.8 and 3.8MeV was determined at the Legnaro CN accelerator at the INFN Laboratories in Legnaro (PD, Italy). This work is relevant for the characterization of SDDs response functions, which are key points for Deuterium-Deuterium and Deuterium-Tritium plasma diagnostic.

  5. Spectroscopic diagnostics of electron temperature and energy conversion efficiency of laser-sustained plasma in flowing argon

    Science.gov (United States)

    Mazumder, J.; Krier, H.; Chen, X.

    1988-08-01

    Laser sustained plasmas are often formed during laser materials interaction. The University's 10 kW CW CO2 laser has been used to study argon plasmas for the application to laser supported propulsion and laser materials processing. The spectroscopic diagnostic method has been applied to study laser-sustained plasmas in 1 atmosphere pure argon gas flow with an f/7 on-axis laser focusing scheme. High flow speeds of 2 to 10 m/sec are achieved. Plasma electron temperatures distributions are determined from the 415.8 nm Ar1 line and its adjacent continuum intensities. Plasma core temperatures as high as 20,000 K are reported. The total absorption of the incident laser power and the radiation loss by the plasma are calculated from the temperature distribution. Results indicated that up to 86 percent of the incident laser power can be absorbed and nearly 60 percent of the incident laser power can be retained by the flowing argon gas to provide thrust. Further research is called for in the Laser Induced Fluorescence (LIF) technique for diagnostics of the downstream mixing zone and the plasma outer region. Experiments over a wider range of operating conditions, as well as multiple plasma testings, are required to find the optimum operating scheme.

  6. Data Acquisition and Automation for Plasma Rotation Diagnostic in the TCABR Tokamak

    Science.gov (United States)

    Ronchi, G.; Severo, J. H. F.; de Sá, W. P.; Galvão, R. M. O.

    2015-03-01

    In this work we describe the implementation of a full modular system of data acquisition and processing for the plasma rotation diagnostic in the TCABR tokamak. The experimental setup uses a single monochromator and six photomultipliers (PMT), in which pair of PMTs measures the light at slightly different wavelengths. Thus, it can measure the time evolution of the Doppler shift of the impurities emission lines coming from three spatial positions (one for toroidal rotation and two for poloidal rotation). The data acquisition and preanalysis program were written with LabVIEW software and is capable of controlling the spectrometer wavelength, PMTs power supplies, data acquisition, and storage. All data are recorded in MDSplus trees that easily allow data visualization and post-processing analysis (both locally and remotely) via MATLAB, Python, Java and others programming languages. This system can run independently from other diagnostics and machine systems and can be integrated with the main tokamak control system by means of TCP/IP messages.

  7. Reproducible diagnostic metabolites in plasma from typhoid fever patients in Asia and Africa

    Science.gov (United States)

    Näsström, Elin; Parry, Christopher M; Vu Thieu, Nga Tran; Maude, Rapeephan R; de Jong, Hanna K; Fukushima, Masako; Rzhepishevska, Olena; Marks, Florian; Panzner, Ursula; Im, Justin; Jeon, Hyonjin; Park, Seeun; Chaudhury, Zabeen; Ghose, Aniruddha; Samad, Rasheda; Van, Tan Trinh; Johansson, Anders; Dondorp, Arjen M; Thwaites, Guy E; Faiz, Abul; Antti, Henrik; Baker, Stephen

    2017-01-01

    Salmonella Typhi is the causative agent of typhoid. Typhoid is diagnosed by blood culture, a method that lacks sensitivity, portability and speed. We have previously shown that specific metabolomic profiles can be detected in the blood of typhoid patients from Nepal (Näsström et al., 2014). Here, we performed mass spectrometry on plasma from Bangladeshi and Senegalese patients with culture confirmed typhoid fever, clinically suspected typhoid, and other febrile diseases including malaria. After applying supervised pattern recognition modelling, we could significantly distinguish metabolite profiles in plasma from the culture confirmed typhoid patients. After comparing the direction of change and degree of multivariate significance, we identified 24 metabolites that were consistently up- or down regulated in a further Bangladeshi/Senegalese validation cohort, and the Nepali cohort from our previous work. We have identified and validated a metabolite panel that can distinguish typhoid from other febrile diseases, providing a new approach for typhoid diagnostics. DOI: http://dx.doi.org/10.7554/eLife.15651.001 PMID:28483042

  8. Resonant scattering as a sensitive diagnostic of current collisional plasma models

    Science.gov (United States)

    Ogorzalek, Anna; Zhuravleva, Irina; Allen, Steven W.; Pinto, Ciro; Werner, Norbert; Mantz, Adam; Canning, Rebecca; Fabian, Andrew C.; Kaastra, Jelle S.; de Plaa, Jelle

    2017-08-01

    Resonant scattering is a subtle process that suppresses fluxes of some of the brightest optically thick X-ray emission lines produced by collisional plasmas in galaxy clusters and massive early-type galaxies. The amplitude of the effect depends on the turbulent structure of the hot gas, making it a sensitive velocity probe. It is therefore crucial to properly model this effect in order to correctly interpret high resolution X-ray spectra. Our measurements of resonant scattering with XMM-Newton Reflection Grating Spectrometer in giant elliptical galaxies and with Hitomi in the center of Perseus Cluster show that the potentially rich inference from this effect is limited by the uncertainties in the atomic data underlying plasma codes such as APEC and SPEX. Typically, the effect is of the order of 10-20%, while the discrepancy between the two codes is of similar order or even higher. Precise knowledge of the emissivity and oscillator strengths of lines emitted by Fe XVII and Fe XXV, as well as their respective uncertainties propagated through plasma codes are key to understanding gas dynamics and microphysics in giant galaxies and cluster ICM, respectively. This is especially crucial for massive ellipticals, where sub-eV resolution would be needed to measure line broadening precisely, making resonant scattering an important velocity diagnostic in these systems for the foreseeable future. In this poster, I will summarize current status of resonant scattering measurements and show how they depend on the assumed atomic data. I will also discuss which improvements are essential to maximize scientific inference from future high resolution X-ray spectra.

  9. Synthetic aperture microwave imaging with active probing for fusion plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Shevchenko, Vladimir F.; Freethy, Simon J.; Huang, Billy K. [EURATOM/CCFE Fusion Association, Culham, Abingdon, Oxon, 0X14 3DB (United Kingdom); Vann, Roddy G. L. [York Plasma Institute, Dept. of Physics, University of York, York YO10 5DD (United Kingdom)

    2014-08-21

    A Synthetic Aperture Microwave Imaging (SAMI) system has been designed and built to obtain 2-D images at several frequencies from fusion plasmas. SAMI uses a phased array of linearly polarised antennas. The array configuration has been optimised to achieve maximum synthetic aperture beam efficiency. The signals received by antennas are down-converted to the intermediate frequency range and then recorded in a full vector form. Full vector signals allow beam focusing and image reconstruction in both real time and a post-processing mode. SAMI can scan over 16 pre-programmed frequencies in the range of 10-35GHz with a switching time of 300ns. The system operates in 2 different modes simultaneously: both a 'passive' imaging of plasma emission and also an 'active' imaging of the back-scattered signal of the radiation launched by one of the antennas from the same array. This second mode is similar to so-called Doppler backscattering (DBS) reflectometry with 2-D resolution of the propagation velocity of turbulent structures. Both modes of operation show good performance in fusion plasma experiments on Mega Amp Spherical Tokamak (MAST). We have obtained the first ever 2-D images of BXO mode conversion windows. With active probing, first ever turbulence velocity maps have been obtained. We present an overview of the diagnostic and discuss recent results. In contrast to quasi-optical microwave imaging systems SAMI requires neither big aperture viewing ports nor large 2-D detector arrays to achieve the desired imaging resolution. The number of effective 'pixels' of the synthesized image is proportional to the number of receiving antennas squared. Thus only a small number of optimised antennas is sufficient for the majority of applications. Possible implementation of SAMI on ITERand DEMO is discussed.

  10. Synthetic aperture microwave imaging with active probing for fusion plasma diagnostics

    Science.gov (United States)

    Shevchenko, Vladimir F.; Freethy, Simon J.; Huang, Billy K.; Vann, Roddy G. L.

    2014-08-01

    A Synthetic Aperture Microwave Imaging (SAMI) system has been designed and built to obtain 2-D images at several frequencies from fusion plasmas. SAMI uses a phased array of linearly polarised antennas. The array configuration has been optimised to achieve maximum synthetic aperture beam efficiency. The signals received by antennas are down-converted to the intermediate frequency range and then recorded in a full vector form. Full vector signals allow beam focusing and image reconstruction in both real time and a post-processing mode. SAMI can scan over 16 pre-programmed frequencies in the range of 10-35GHz with a switching time of 300ns. The system operates in 2 different modes simultaneously: both a 'passive' imaging of plasma emission and also an 'active' imaging of the back-scattered signal of the radiation launched by one of the antennas from the same array. This second mode is similar to so-called Doppler backscattering (DBS) reflectometry with 2-D resolution of the propagation velocity of turbulent structures. Both modes of operation show good performance in fusion plasma experiments on Mega Amp Spherical Tokamak (MAST). We have obtained the first ever 2-D images of BXO mode conversion windows. With active probing, first ever turbulence velocity maps have been obtained. We present an overview of the diagnostic and discuss recent results. In contrast to quasi-optical microwave imaging systems SAMI requires neither big aperture viewing ports nor large 2-D detector arrays to achieve the desired imaging resolution. The number of effective 'pixels' of the synthesized image is proportional to the number of receiving antennas squared. Thus only a small number of optimised antennas is sufficient for the majority of applications. Possible implementation of SAMI on ITERand DEMO is discussed.

  11. Application and Continued Development of Thin Faraday Collectors as a Lost Ion Diagnostic for Tokamak Fusion Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    F. Ed Cecil

    2011-06-30

    This report summarizes the accomplishment of sixteen years of work toward the development of thin foil Faraday collectors as a lost energetic ion diagnostic for high temperature magnetic confinement fusion plasmas. Following initial, proof of principle accelerator based studies, devices have been tested on TFTR, NSTX, ALCATOR, DIII-D, and JET (KA-1 and KA-2). The reference numbers refer to the attached list of publications. The JET diagnostic KA-2 continues in operation and hopefully will provide valuable diagnostic information during a possible d-t campaign on JET in the coming years. A thin Faraday foil spectrometer, by virtue of its radiation hardness, may likewise provide a solution to the very challenging problem of lost alpha particle measurements on ITER and other future burning plasma machines.

  12. An in situ accelerator-based diagnostic for plasma-material interactions science on magnetic fusion devices

    Science.gov (United States)

    Hartwig, Zachary S.; Barnard, Harold S.; Lanza, Richard C.; Sorbom, Brandon N.; Stahle, Peter W.; Whyte, Dennis G.

    2013-12-01

    This paper presents a novel particle accelerator-based diagnostic that nondestructively measures the evolution of material surface compositions inside magnetic fusion devices. The diagnostic's purpose is to contribute to an integrated understanding of plasma-material interactions in magnetic fusion, which is severely hindered by a dearth of in situ material surface diagnosis. The diagnostic aims to remotely generate isotopic concentration maps on a plasma shot-to-shot timescale that cover a large fraction of the plasma-facing surface inside of a magnetic fusion device without the need for vacuum breaks or physical access to the material surfaces. Our instrument uses a compact (˜1 m), high-current (˜1 milliamp) radio-frequency quadrupole accelerator to inject 0.9 MeV deuterons into the Alcator C-Mod tokamak at MIT. We control the tokamak magnetic fields - in between plasma shots - to steer the deuterons to material surfaces where the deuterons cause high-Q nuclear reactions with low-Z isotopes ˜5 μm into the material. The induced neutrons and gamma rays are measured with scintillation detectors; energy spectra analysis provides quantitative reconstruction of surface compositions. An overview of the diagnostic technique, known as accelerator-based in situ materials surveillance (AIMS), and the first AIMS diagnostic on the Alcator C-Mod tokamak is given. Experimental validation is shown to demonstrate that an optimized deuteron beam is injected into the tokamak, that low-Z isotopes such as deuterium and boron can be quantified on the material surfaces, and that magnetic steering provides access to different measurement locations. The first AIMS analysis, which measures the relative change in deuterium at a single surface location at the end of the Alcator C-Mod FY2012 plasma campaign, is also presented.

  13. PREFACE: Fourteenth International Symposium on Laser-Aided Plasma Diagnostics (LAPD14)

    Science.gov (United States)

    Giudicotti, L.; Pasqualotto, R.

    2010-04-01

    The attached PDF contains, the full preface, a list of the scientific committee, former LAPD chairmen, local organizers, previous locations of LAPD meetings, participants email contacts and a list of the contributed papers. logo The Fourteenth International Symposium on Laser-Aided Plasma Diagnostics (LAPD14), was held from 21-24 September 2009 in Castelbrando, Treviso, Italy. The series of LAPD symposia was originally started at Kyushu University in 1983, and since then it has been organized every two years alternately in Japan, Europe and the United States, traveling around the world five times. Each LAPD Symposium brings together scientists working in different disciplines all related to the diagnostics of any type of plasma by laser or similar techniques. Researchers working on nuclear fusion, industrial process, low temperature plasma chemistry, laser development and material science, are invited to present prominent new diagnostic developments, with the aim of synergetic discussions. The broad spectrum of contributions represents one of the strengths of this symposium, which is an important, unique and fruitful source of cross-fertilization between these fields and a forum of discussions. The scope of LAPD14 was very broad, including many techniques related to laser probing of plasmas: incoherent and coherent Thomson scattering, polarimetry, interferometry, reflectometry, laser induced fluorescence, laser absorption spectroscopy, laser photodetachment spectroscopy, cavity ringdown spectroscopy, Raman scattering, reflectometry, microwave diagnostics and related laser and hardware developments. LAPD14 was attended by 66 researchers, from 15 different countries who presented a total of 57 papers (13 general, 12 topical, 10 short talks and 23 poster contributions). It is a tradition of LAPD that the first lecture of each meeting, which is more general and aims to review prominent new developments, is called 'the Akazaki lecture' in honor of Professor Masanori

  14. Study on re-sputtering during CN{sub x} film deposition through spectroscopic diagnostics of plasma

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Peipei; Yang, Xu; Li, Hui; Cai, Hua [Department of Optical Science and Engineering, Fudan University, Shanghai 200433 (China); Sun, Jian; Xu, Ning [Department of Optical Science and Engineering, Fudan University, Shanghai 200433 (China); Shanghai Engineering Research Center of Ultra-Precision Optical Manufacturing, Fudan University, Shanghai 200433 (China); Wu, Jiada, E-mail: jdwu@fudan.edu.cn [Department of Optical Science and Engineering, Fudan University, Shanghai 200433 (China); Shanghai Engineering Research Center of Ultra-Precision Optical Manufacturing, Fudan University, Shanghai 200433 (China); Engineering Research Center of Advanced Lighting Technology, Ministry of Education, Fudan University, Shanghai 200433 (China)

    2015-10-15

    A nitrogen-carbon plasma was generated during the deposition of carbon nitride (CN{sub x}) thin films by pulsed laser ablation of a graphite target in a discharge nitrogen plasma, and the optical emission of the generated nitrogen-carbon plasma was measured for the diagnostics of the plasma and the characterization of the process of CN{sub x} film deposition. The nitrogen-carbon plasma was recognized to contain various species including nitrogen molecules and molecular ions excited in the ambient N{sub 2} gas, carbon atoms and atomic ions ablated from the graphite target and CN radicals. The temporal evolution and spatial distribution of the CN emission and their dependence on the substrate bias voltage show two groups of CN radicals flying in opposite directions. One represents the CN radicals formed as the products of the reactions occurring in the nitrogen-carbon plasma, revealing the reactive deposition of CN{sub x} film due to the reactive expansion of the ablation carbon plasma in the discharge nitrogen plasma and the effective formation of gaseous CN radicals as precursors for CN{sub x} film growth. The other one represents the CN radicals re-sputtered from the growing CN{sub x} film by energetic plasma species, evidencing the re-sputtering of the growing film accompanying film growth. And, the re-sputtering presents ion-induced sputtering features.

  15. Feasibility of arc-discharge and plasma-sputtering methods in cleaning plasma-facing and diagnostics components of fusion reactors

    Energy Technology Data Exchange (ETDEWEB)

    Hakola, Antti, E-mail: antti.hakola@vtt.fi [VTT Technical Research Centre of Finland, VTT (Finland); Likonen, Jari [VTT Technical Research Centre of Finland, VTT (Finland); Karhunen, Juuso; Korhonen, Juuso T. [Department of Applied Physics, Aalto University (Finland); Aints, Märt; Laan, Matti; Paris, Peeter [Department of Physics, University of Tartu (Estonia); Kolehmainen, Jukka; Koskinen, Mika; Tervakangas, Sanna [DIARC-Technology Oy, Espoo (Finland)

    2015-10-15

    Highlights: • Feasibility of the arc-discharge and plasma-sputtering techniques in removing deposited layers from ITER-relevant samples demonstrated. • Samples with the size of an A4 paper can be cleaned from 1-μm thick deposited layers in 10–20 minutes by the arc-discharge method. • The plasma-sputtering method is 5–10 times slower but the resulting surfaces are very smooth. • Arc-discharge method could be used for rapid cleaning of plasma-facing components during maintenance shutdowns of ITER, plasma sputtering is preferred for diagnostics mirrors. - Abstract: We have studied the feasibility of arc-discharge and plasma-sputtering methods in removing deposited layers from ITER-relevant test samples. Prototype devices have been designed and constructed for the experiments and the cleaning process is monitored by a spectral detection system. The present version of the arc-discharge device is capable of removing 1-μm thick layers from 350-mm{sup 2} areas in 4–8 s, but due to the increased roughness of the cleaned surfaces and signs of local melting, mirror-like surfaces cannot be treated by this technique. The plasma-sputtering approach, for its part, is some 5–10 times slower in removing the deposited layers but no changes in surface roughness or morphology of the samples could be observed after the cleaning phase. The arc-discharge technique could therefore be used for rapid cleaning of plasma-facing components during maintenance shutdowns of ITER while in the case of diagnostics mirrors plasma sputtering is preferred.

  16. Spectro-Polarimetric Observations of Interplanetary Hydrogen as a Diagnostic of the Heliopause Plasma Boundary

    Science.gov (United States)

    Harris, W.; Ben-Jaffel, L.; Roesler, F.; Corliss, J.; Dawson, O.; Giersch, L.

    2006-12-01

    Neutral interplanetary hydrogen (IPH) does not originate in the solar system, but is dominated by material in the interstellar medium (ISM) that has penetrated into the solar system. This material is not pristine or thermal in its properties, but contains a record of both the ISM and its passage across the broad mixing- plasma boundary formed by the interaction of the Solar wind and the ionized component of the ISM. This record is provided by charge exchange interactions between hydrogen atoms and protons in the boundary region that effectively translate the characteristics of the plasma interaction and boundary region to the non- interacting neutral population. The primary observational technique used to observe IPH is resonance scattering of solar Ly-alpha emission in the optically thick medium. These data show evidence of line of sight dependent line-broadening and deceleration associated with the boundary crossing. Here we describe a new class of instrument, a spatial-heterodyne spectro-polarimeter (SHSPOL) that offers improved diagnostic capabilities for the study of the IPH. SHSPOL combines the high sensitivity and spectral resolving power of SHS with a novel far ultraviolet polarimeter design. Combined, these technologies permit rapid accumulation of IPH line-shape measurements with the added measurement of the offers a new way to explore the radial properties of the IPH along a given line of sight from the scattering angle dependent polarization of the incoming light. We will discuss the principle of SHSPOL and our development of prototype instrument for observing the IPH from a sounding rocket platform.

  17. Plasma diagnostic approach for the low-temperature deposition of silicon quantum dots using dual frequency PECVD

    Science.gov (United States)

    Sahu, B. B.; Yin, Y.; Lee, J. S.; Han, Jeon G.; Shiratani, M.

    2016-10-01

    Although studies of silicon (Si) quantum dots (QDs) were started just a few years ago, progress is noteworthy concerning unique film properties and their potential application for devices. In particular, relating to the Si QD process optimization, it is essential to control the deposition environment by studying the role of plasma parameters and atomic and molecular species in the process plasmas. In this work, we report on advanced material processes for the low-temperature deposition of Si QDs by utilizing radio frequency and ultrahigh frequency dual frequency (DF) plasma enhanced chemical vapor deposition (PECVD) method. DF PECVD can generate a very high plasma density in the range ~9  ×  1010 cm-3 to 3.2  ×  1011 cm-3 at a very low electron temperature (T e) ~ 1.5 to 2.4 eV. The PECVD processes, using a reactive mixture of H2/SiH4/NH3 gases, are carefully studied to investigate the operating regime and to optimize the deposition parameters by utilizing different plasma diagnostic tools. The analysis reveals that a higher ion flux at a higher plasma density on the substrate is conducive to enhancing the overall crystallinity of the deposited film. Along with high-density plasmas, a high concentration of atomic H and N is simultaneously essential for the high growth rate deposition of Si QDs. Numerous plasma diagnostics methods and film analysis tools are used to correlate the effect of plasma- and atomic-radical parameters on the structural and chemical properties of the deposited Si QD films prepared in the reactive mixtures of H2/SiH4/NH3 at various pressures.

  18. Diagnostic development in precise opacity measurement of radiatively heated Al plasma on Shenguang II laser facility

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Yang [Wuhan National Laboratory for Optoelectronics, Institute of Optoelectronics Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Yang Jiamin; Zhang Jiyan [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Liu Jinsong; Yuan Xiao [Wuhan National Laboratory for Optoelectronics, Institute of Optoelectronics Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Jin Fengtao [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Department of Physics, National University of Defense Technology, Changsha 410073 (China)

    2009-04-15

    Simultaneous measurements of the self-emission spectrum, the backlighting source spectrum, and the transmission spectrum in one shot, which reduce the experimental uncertainties from shot-to-shot fluctuation, are essential for precise opacity experiments. In order to achieve precise absorption spectrum of Al plasmas, a special half sample sandwich target was designed and short backlighter was used to provide time- and space-resolving diagnostics on the Shenguang II high power laser facility. In the measurement, a cylindrical cavity with CH foam baffles was used to provide a clean x-ray radiation environment for sample heating. The x-ray source spectrum, the transmission spectrum, and the self-emission spectrum of the soft x-ray heated Al sample were recorded in one shot with a penta-erythritol tetrakis (hydroxymethy) methane C(CH{sub 2}OH){sub 4} (PET) crystal spectrometer by using the point-projection method. Experimental results have been compared with the calculation results of a detailed level accounting opacity code.

  19. Fast data transmission in dynamic data acquisition system for plasma diagnostics

    Science.gov (United States)

    Byszuk, Adrian; Poźniak, Krzysztof; Zabołotny, Wojciech M.; Kasprowicz, Grzegorz; Wojeński, Andrzej; Cieszewski, Radosław; Juszczyk, Bartłomiej; Kolasiński, Piotr; Zienkiewicz, Paweł; Chernyshova, Maryna; Czarski, Tomasz

    2014-11-01

    This paper describes architecture of a new data acquisition system (DAQ) targeted mainly at plasma diagnostic experiments. Modular architecture, in combination with selected hardware components, allows for straightforward reconfiguration of the whole system, both offline and online. Main emphasis will be put into the implementation of data transmission subsystem in said system. One of the biggest advantages of described system is modular architecture with well defined boundaries between main components: analog frontend (AFE), digital backplane and acquisition/control software. Usage of a FPGA chips allows for a high flexibility in design of analog frontends, including ADC FPGA interface. Data transmission between backplane boards and user software was accomplished with the use of industry-standard PCI Express (PCIe) technology. PCIe implementation includes both FPGA firmware and Linux device driver. High flexibility of PCIe connections was accomplished due to use of configurable PCIe switch. Whenever it's possible, described DAQ system tries to make use of standard off-the-shelf (OTF) components, including typical x86 CPU & motherboard (acting as PCIe controller) and cabling.

  20. DIRECT SMEAR VS CELL BLOCK (PLASMA- THROMBIN CLOT METHOD: DIAGNOSTIC VALUE IN SEROSAL CAVITIES FLUIDS CYTOLOGY

    Directory of Open Access Journals (Sweden)

    P MAHZOUNI

    2000-03-01

    Full Text Available Introduction. To improve testing sensitivity, most laboratories use two or more preparation methods but in our laboratories only one method is used which is "direct smear". In this study we tried to evaluate the diagnostic value of cell block as adjunct to direct smear in the cytologic investigation of serosal cavities fluids. Methods. In a clinical trial study 62 specimens of serosal cavity fluids were investigated in AL-Zahrapathology laboratory (Get. 1998 to Get. 1999. Cytologic slides from each specimens were prepared in two methods: direct smear and cell block (plasma- thrombin clot method. Smears and cell blocks were studied separately by the same cytopathologist. The diagnosis were categorized as positive, negative, suspicious or unsatisfactory. Also, the time required for studing of each slides were noted. Findings. The findings indicated that there are discrepancy between direct smear and cell block methods in the number of "suspicious" cases. Also there is significant difference between the mean time needed for studing of direct smear and cell block. Conclusion. It is recommended that the remainer of each specimen should be kept in refrigerator in order to prepare cell blocks in suspicious cases of direct smear. This method facilitates making a more definite diagnosis and reducing the number of suspicious cases.

  1. A diamond based neutron spectrometer for diagnostics of deuterium-tritium fusion plasmas

    Science.gov (United States)

    Cazzaniga, C.; Nocente, M.; Rebai, M.; Tardocchi, M.; Calvani, P.; Croci, G.; Giacomelli, L.; Girolami, M.; Griesmayer, E.; Grosso, G.; Pillon, M.; Trucchi, D. M.; Gorini, G.

    2014-11-01

    Single crystal Diamond Detectors (SDD) are being increasingly exploited for neutron diagnostics in high power fusion devices, given their significant radiation hardness and high energy resolution capabilities. The geometrical efficiency of SDDs is limited by the size of commercially available crystals, which is often smaller than the dimension of neutron beams along collimated lines of sight in tokamak devices. In this work, we present the design and fabrication of a 14 MeV neutron spectrometer consisting of 12 diamond pixels arranged in a matrix, so to achieve an improved geometrical efficiency. Each pixel is equipped with an independent high voltage supply and read-out electronics optimized to combine high energy resolution and fast signals (1 MHz) spectroscopy. The response function of a prototype SDD to 14 MeV neutrons has been measured at the Frascati Neutron Generator by observation of the 8.3 MeV peak from the 12C(n, α)9Be reaction occurring between neutrons and 12C nuclei in the detector. The measured energy resolution (2.5% FWHM) meets the requirements for neutron spectroscopy applications in deuterium-tritium plasmas.

  2. A diamond based neutron spectrometer for diagnostics of deuterium-tritium fusion plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Cazzaniga, C., E-mail: carlo.cazzaniga@mib.infn.it; Nocente, M.; Gorini, G. [University of Milano Bicocca, Piazza della Scienza 3, Milano (Italy); Istituto di Fisica del Plasma, Associazione EURATOM-ENEA-CNR, via Roberto Cozzi 53, Milano (Italy); Rebai, M.; Giacomelli, L. [University of Milano Bicocca, Piazza della Scienza 3, Milano (Italy); Tardocchi, M.; Croci, G.; Grosso, G. [Istituto di Fisica del Plasma, Associazione EURATOM-ENEA-CNR, via Roberto Cozzi 53, Milano (Italy); Calvani, P.; Girolami, M.; Trucchi, D. M. [CNR-ISM, Research Area Roma 1, Via Salaria km 29.300, 00015-Monterotondo Scalo (Rm) (Italy); Griesmayer, E. [Atominstitut, Vienna University of Technology, Vienna (Austria); Pillon, M. [Associazione EURATOM-ENEA sulla Fusione ENEA C.R. Frascati, Via E. Fermi, 45, 00044 Frascati (Roma) (Italy)

    2014-11-15

    Single crystal Diamond Detectors (SDD) are being increasingly exploited for neutron diagnostics in high power fusion devices, given their significant radiation hardness and high energy resolution capabilities. The geometrical efficiency of SDDs is limited by the size of commercially available crystals, which is often smaller than the dimension of neutron beams along collimated lines of sight in tokamak devices. In this work, we present the design and fabrication of a 14 MeV neutron spectrometer consisting of 12 diamond pixels arranged in a matrix, so to achieve an improved geometrical efficiency. Each pixel is equipped with an independent high voltage supply and read-out electronics optimized to combine high energy resolution and fast signals (<30 ns), which are essential to enable high counting rate (>1 MHz) spectroscopy. The response function of a prototype SDD to 14 MeV neutrons has been measured at the Frascati Neutron Generator by observation of the 8.3 MeV peak from the {sup 12}C(n, α){sup 9}Be reaction occurring between neutrons and {sup 12}C nuclei in the detector. The measured energy resolution (2.5% FWHM) meets the requirements for neutron spectroscopy applications in deuterium-tritium plasmas.

  3. Novel diagnostics of metabolic dysfunction detected in breath and plasma by selective isotope assisted labeling (SIAL)

    Science.gov (United States)

    Haviland, Julia A.; Tonelli, Marco; Haughey, Dermot T.; Porter, Warren P.; Assadi-Porter, Fariba M.

    2012-01-01

    OBJECTIVE Metabolomics is the study of a unique fingerprint of small molecules present in biological systems under healthy and disease conditions. One of the major challenges in metabolomics is validation of fingerprint molecules to identify specifically perturbed pathways in metabolic aberrations. This step is crucial to the understanding of budding metabolic pathologies and the ability to identify early indicators of common diseases such as obesity, diabetes mellitus type II, metabolic syndrome, polycystic ovary syndrome, and cancer. We present a novel approach to diagnosing aberrations in glucose utilization including metabolic pathway switching in a disease state. METHODS We used a well-defined prenatally exposed glucocorticoid mouse model that results in adult females with metabolic dysfunction. We applied the complementary technologies of nuclear magnetic resonance spectroscopy, and cavity ringdown spectroscopy to analyze serial plasma samples and real-time breath measurements following selective 13C-isotope assisted labeling (SIAL). These platforms allowed us to trace metabolic markers in whole animals and identify key metabolic pathway switching in prenatally glucocorticoid-treated animals. RESULTS Total glucose flux is significantly proportionally increased through the major oxidative pathways of glycolysis and the pentose phosphate pathway in the prenatally glucocorticoid-treated animals relative to the control animals. CONCLUSION This novel diagnostics approach is fast, non-invasive and sensitive for determining specific pathway utilization, and provides a direct translational application in the healthcare field. PMID:22304834

  4. Expansion tunnel characterization and development of non-intrusive microwave plasma diagnostics

    Science.gov (United States)

    Dufrene, Aaron T.

    The focus of this research is the development of non-intrusive microwave diagnostics for characterization of expansion tunnels. The main objectives of this research are to accurately characterize the LENS XX expansion tunnel facility, develop non-intrusive RF diagnostics that will work in short-duration expansion tunnel testing, and to determine plasma properties and other information that might otherwise be unknown, less accurate, intrusive, or more difficult to determine through conventional methods. Testing was completed in LENS XX, a new large-scale expansion tunnel facility at CUBRC, Inc. This facility is the largest known expansion tunnel in the world with an inner diameter of 24 inches, a 96 inch test section, and an end-to-end length of more than 240 ft. Expansion tunnels are currently the only facilities capable of generating high-enthalpy test conditions with minimal or no freestream dissociation or ionization. However, short test times and freestream noise at some conditions have limited development of these facilities. To characterize the LENS XX facility, the first step is to evaluate the facility pressure, vacuum, temperature, and other mechanical restrictions to derive a theoretical testing parameter space. Test condition maps are presented for a variety of parameters and gases based on 1D perfect gas dynamics. Test conditions well beyond 10 km/s or 50 MJ/kg are identified with minimum test times of 200 us. Additionally, a four-chamber expansion tube configuration is considered for extending the stagnation enthalpy range of the facility even further. A microwave shock speed diagnostic measures primary and secondary shock speeds accurately every 30 in. down the entire length of the facility resulting in a more accurate determination of freestream conditions required for computational comparisons. The high resolution of this measurement is used to assess shock speed attenuation as well as secondary diaphragm performance. Negligible shock attenuation is

  5. Betatron radiation based diagnostics for plasma wakefield accelerated electron beams at the SPARC_LAB test facility

    Science.gov (United States)

    Shpakov, V.; Anania, M. P.; Biagioni, A.; Chiadroni, E.; Cianchi, A.; Curcio, A.; Dabagov, S.; Ferrario, M.; Filippi, F.; Marocchino, A.; Paroli, B.; Pompili, R.; Rossi, A. R.; Zigler, A.

    2016-09-01

    Recent progress with wake-field acceleration has shown a great potential in providing high gradient acceleration fields, while the quality of the beams remains relatively poor. Precise knowledge of the beam size at the exit from the plasma and matching conditions for the externally injected beams are the key for improvement of beam quality. Betatron radiation emitted by the beam during acceleration in the plasma is a powerful tool for the transverse beam size measurement, being also non-intercepting. In this work we report on the technical solutions chosen at SPARC_LAB for such diagnostics tool, along with expected parameters of betatron radiation.

  6. Application of piezodetectors for diagnostics of pulsed and quasi-steady-state plasma streams

    Energy Technology Data Exchange (ETDEWEB)

    Bandura, A.N.; Chebotarev, V.V.; Garkusha, I.E.; Tereshin, V.I.; Ladygina, M.S. [NSC KIPT, Kharkov (Ukraine). Inst. of Plasma Physics

    2006-04-15

    The paper reports on studies of the plasma streams generated by two experimental devices: the quasi-steady-state plasma accelerator (QSPA) Kh-50 and the pulsed plasma gun PROSVET. The radial distributions of the plasma pressure for different times and varied distances from the accelerator output have been used for investigation of the plasma stream dynamics and study the plasma compression in the focus region for different operational regimes of plasma accelerators. In experiments for the application of pulsed plasma streams for surface modification of different industrial steels, optimal regimes of surface processing have been chosen on the basis of the plasma pressure measurements. Examples of application of the piezodetectors in simulation experiments on plasma surface interaction under high heat loads are presented.

  7. Progress in Development of C60 Nanoparticle Plasma Jet for Diagnostic of Runaway Electron Beam-Plasma Interaction and Disruption Mitigation Study for ITER

    Science.gov (United States)

    Bogatu, I. N.; Thompson, J. R.; Galkin, S. A.; Kim, J. S.

    2013-10-01

    We produced a C60 nanoparticle plasma jet (NPPJ) with uniquely fast response-to-delivery time (~ 1 - 2 ms) and unprecedentedly high momentum (~ 0 . 6 g .km/s). The C60 NPPJ was obtained by using a solid state TiH2/C60 pulsed power cartridge producing ~180 mg of C60 molecular gas by sublimation and by electromagnetic acceleration of the C60 plasma in a coaxial gun (~35 cm length, 96 kJ energy) with the output of a high-density (>1023 m-3) hyper-velocity (>4 km/s) plasma jet. The ~ 75 mg C60/C plasma jet has the potential to rapidly and deeply deliver enough mass to significantly increase electron density (to ne ~ 2 . 4 ×1021 m-3, i.e. ~ 60 times larger than typical DIII-D pre-disruption value, ne 0 ~ 4 ×1019 m-3), and to modify the 'critical electric field' and the runaway electrons (REs) collisional drag during different phases of REs dynamics. The C60 NPPJ, as a novel injection technique, allows RE beam-plasma interaction diagnostic by quantitative spectroscopy of C ions visible/UV line intensity. The system is scalable to ~ 1 - 2 g C60/C plasma jet output and technology is adaptable to ITER acceptable materials (BN and Be) for disruption mitigation. Work supported by US DOE DE-FG02-08ER85196 grant.

  8. The cluster charge identification in the GEM detector for fusion plasma imaging by soft X-ray diagnostics

    Science.gov (United States)

    Czarski, T.; Chernyshova, M.; Malinowski, K.; Pozniak, K. T.; Kasprowicz, G.; Kolasinski, P.; Krawczyk, R.; Wojenski, A.; Zabolotny, W.

    2016-11-01

    The measurement system based on gas electron multiplier detector is developed for soft X-ray diagnostics of tokamak plasmas. The multi-channel setup is designed for estimation of the energy and the position distribution of an X-ray source. The focal measuring issue is the charge cluster identification by its value and position estimation. The fast and accurate mode of the serial data acquisition is applied for the dynamic plasma diagnostics. The charge clusters are counted in the space determined by 2D position, charge value, and time intervals. Radiation source characteristics are presented by histograms for a selected range of position, time intervals, and cluster charge values corresponding to the energy spectra.

  9. The cluster charge identification in the GEM detector for fusion plasma imaging by soft X-ray diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Czarski, T., E-mail: tomasz.czarski@ifpilm.pl; Chernyshova, M.; Malinowski, K. [Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw (Poland); Pozniak, K. T.; Kasprowicz, G.; Kolasinski, P.; Krawczyk, R.; Wojenski, A.; Zabolotny, W. [Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw (Poland)

    2016-11-15

    The measurement system based on gas electron multiplier detector is developed for soft X-ray diagnostics of tokamak plasmas. The multi-channel setup is designed for estimation of the energy and the position distribution of an X-ray source. The focal measuring issue is the charge cluster identification by its value and position estimation. The fast and accurate mode of the serial data acquisition is applied for the dynamic plasma diagnostics. The charge clusters are counted in the space determined by 2D position, charge value, and time intervals. Radiation source characteristics are presented by histograms for a selected range of position, time intervals, and cluster charge values corresponding to the energy spectra.

  10. Development of ion diagnostic system based on electrostatic probe in the boundary plasma of the JFT-2M tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Uehara, Kazuya; Kawakami, Tomohide [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Amemiya, Hiroshi; Hoethker, K.; Cosler, A.; Bieger, W.

    1995-06-01

    An ion diagnostic system using electrostatic probes for measurements in the JFT-2M tokamak boundary plasma has been developed under the collaboration program between KFA and JAERI. The rotating double probe system, on which the Hoethker double probe and Amemiya asymmetric probe can mounted, are manufactured at KFA workshop while the linear driver to support the rotating double probe, the ion toothbrush probe, the Katsumata probe and the cubic Mach probe are developed at JAERI. This report describes the hardware of this probe system for ion diagnostics in the boundary plasma and preliminary data obtained by means of this system. Furthermore, results on the transport are estimated on the basis of these probe data. (author).

  11. Pretreatment plasma levels and diagnostic utility of hematopoietic cytokines in cervical cancer or cervical intraepithelial neoplasia patients.

    Science.gov (United States)

    Ławicki, Sławomir; Będkowska, Grażyna E; Gacuta-Szumarska, Ewa; Knapp, Paweł; Szmitkowski, Maciej

    2012-07-04

    In this study, we compared plasma levels and the diagnostic utility of hematopoietic growth factors (HGFs) with SCC-Ag in cervical cancer patients in relation to control groups and cervical intraepithelial neoplasia (CIN) patients and healthy subjects. Pretreatment plasma levels of HGFs (SCF, GM-CSF, G-CSF and M-CSF) were determined by the use of immunoenzyme assay (ELISA), and SCC-Ag by chemiluminescent microparticle immunoassay (CMIA). Significantly different concentrations of GM-CSF, G-CSF and M-CSF were observed in the group of patients with cervical cancer and CIN compared to the healthy controls. Significant differences in plasma levels of GM-CSF and M-CSF between cervical cancer and benign lesions patients were also found. The HGFs and SCC-Ag diagnostic specificities received high values. The diagnostic sensitivity and the predictive value of a positive and negative test result were higher for M-CSF than for antigen SCC in the cancer group. The M-CSF area under the ROC curve (AUC) was the largest from hematopoietic cytokines and SCC-Ag. These results suggest the potential utility of M-CSF as a good candidate for a marker of cervical cancer as well as benign lesions of this organ (CIN).

  12. Data acquisition and real-time signal processing of plasma diagnostics on ASDEX Upgrade using LabVIEW RT

    Energy Technology Data Exchange (ETDEWEB)

    Giannone, L., E-mail: Louis.Giannone@ipp.mpg.d [Max-Planck-Institut fuer Plasmaphysik, EURATOM-IPP Association, D-85748 Garching (Germany); Cerna, M. [National Instruments, Austin, TX 78759-3504 (United States); Cole, R.; Fitzek, M. [Unlimited Computer Systems GmbH, 82393 Iffeldorf (Germany); Kallenbach, A. [Max-Planck-Institut fuer Plasmaphysik, EURATOM-IPP Association, D-85748 Garching (Germany); Lueddecke, K. [Unlimited Computer Systems GmbH, 82393 Iffeldorf (Germany); McCarthy, P.J. [Department of Physics, University College Cork, Association EURATOM-DCU, Cork (Ireland); Scarabosio, A.; Schneider, W.; Sips, A.C.C.; Treutterer, W. [Max-Planck-Institut fuer Plasmaphysik, EURATOM-IPP Association, D-85748 Garching (Germany); Vrancic, A.; Wenzel, L.; Yi, H. [National Instruments, Austin, TX 78759-3504 (United States); Behler, K.; Eich, T.; Eixenberger, H.; Fuchs, J.C.; Haas, G.; Lexa, G. [Max-Planck-Institut fuer Plasmaphysik, EURATOM-IPP Association, D-85748 Garching (Germany)

    2010-07-15

    The existing VxWorks real-time system for the position and shape control in ASDEX Upgrade has been extended to calculate magnetic flux surfaces in real-time using a multi-core PCI Express system running LabVIEW RT 8.6. real-time signal processing of bolometers and manometers is performed with the on-board FPGA to calculate the measured radiated power flux and particle flux respectively from the raw data. Radiation feedback experiments use halo current measurements from the outer divertor with real-time median filter pre-processing to remove the excursions produced by ELMs. Integration of these plasma diagnostics into the control system by the exchange of XML sheets for communicating the real-time variables to be produced and consumed is in operation. Reflective memory and UDP are employed by the LabVIEW RT plasma diagnostics to communicate with the control system and other plasma diagnostics in a multi-platform real-time network.

  13. Growth of γ-alumina thin films by pulsed laser deposition and plasma diagnostic

    Science.gov (United States)

    Yahiaoui, K.; Abdelli-Messaci, S.; Messaoud Aberkane, S.; Siad, M.; Kellou, A.

    2017-07-01

    The present work discusses about the synthesis of alumina thin films, which have applications in current and next-generation solid-state electronic devices due to their attractive properties. Alumina thin films were synthesized by pulsed laser deposition at different oxygen pressures and substrate temperatures. The dependence of substrate temperature, oxygen pressure, and the deposition time on the properties of the films has been observed by growing three series of alumina thin films on Si (100). The first films are synthesized using substrate temperatures ranging from room temperature to 780 °C at 0.01 mbar of O2. The second series was realized at a fixed substrate temperature of 760 °C and varied oxygen pressure (from 0.005 to 0.05 mbar). The third set of series was elaborated at different deposition times (from 15 to 60 min) while the oxygen pressure and the substrate temperature were fixed at 0.01 mbar and 760 °C, respectively. The films were characterized using X-ray diffractometer (XRD) for structural analysis, a scanning electron microscope for morphological analysis, a nano-indenter for mechanical analysis (hardness and Young's modulus), and Rutherford backscattering spectroscopy for thickness and stoichiometry measurements. Using optical emission spectroscopy, plasma diagnostic was carried out both in the vacuum and in the presence of oxygen with a pressure ranging from 0.01 to 0.05 mbar. Several neutral, ionic, and molecular species were identified such as Al, Al+, and Al++ in vacuum and in oxygen ambiance, O and AlO molecular bands in oxygen-ambient atmosphere. The spatiotemporal evolution of the most relevant species was achieved and their velocities were estimated. The highest amount of crystallized alumina in γ-phase was found in the films elaborated under 0.01 mbar of O2, at a substrate temperature of 780 °C, and a deposition time of 60 min.

  14. High-pressure duo-multichannel soft x-ray spectrometer for tokamak plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Schwob, J.L.; Wouters, A.W.; Suckewer, S.

    1987-03-01

    A high-resolution, time-resolving soft X-ray multichannel spectrometer (SOXMOS) that permits the simultaneous measurement of emission in two different spectral ranges has been developed and tested extensively for tokamak plasma diagnostics. The basic instrument is a high-resolution, interferometrically adjusted, extreme grazing incidence Schwob-Fraenkel duochromator. The instrument is equipped with two multichannel detectors that are adjusted interferometrically and scan along the Rowland circle. Each consists of an MgF/sub 2/ coated, funneled microchannel plate, associated with a phosphor screen image intensifier that is coupled to a 1024-element photodiode array by a flexible fibrer optic conduit. The total wavelength coverage of the instrument is 5 to 340/sup 0/ A with a measured resolution (FWHM) of about 0.2 A when equipped with a 600 g/mm grating, and 5 to 85 A with a resolution of about 0.06 A using a 2400 g/mm grating. The simultaneous spectral coverage of each detector varies from 15 A at the short wavelength limit to 70 A at the long wavelength limit with the lower dispersion grating. The minimum read-out time for a full spectral portion is 17 ms, but several individual lines can be measured with 1 ms time resolution by selected pixel readout. Higher time resolution can be achieved by replacing one multichannel detector with a single channel electron multiplier detector. Examples of data from the PLT and TFTR tokamaks are presented to illustrate the instrument's versatility, high spectral resolution, and high signal-to-noise ratio even in the 10 A region. 44 refs., 20 figs.

  15. Development of x-ray and ion diagnostics of plasma obtained with a 10-TW femtosecond laser

    Science.gov (United States)

    Ryć, L.; Dobrzański, L.; Dubecky, F.; Jabłoński, S.; Parys, P.; Słysz, W.; Rosiński, M.

    2016-07-01

    Several x-ray and ion semiconductor detectors have been developed for the diagnostics of femtosecond laser plasma generated by a 10-TW laser which was recently commissioned for operation at the Institute of Plasma Physics and Laser Microfusion, Warsaw. A range of detectors has been employed including a CdTe detector for hard x-rays and four detectors for proton detection. These four are SiC and GaN employing a sandwich structure, an interdigitated M-S-M InP detector and finally a silicon photo-diode equipped with an aluminium filter (to shield against scattered light). The detectors presented are innovative as they are not commonly used for the diagnostic of laser plasma. The details of the internal structures of the detectors are presented. The immunity of the detectors to the noise coming from the laser system and the femtosecond plasma is discussed. Lastly, the possibility for further modifications and improvements are considered and discussed.

  16. Ionization energy shift of characteristic K x-ray lines from high-Z materials for plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Słabkowska, K.; Szymańska, E.; Polasik, M. [Faculty of Chemistry, Nicholas Copernicus University, 87-100 Toruń (Poland); Pereira, N. R. [Ecopulse, Inc., 7844 Vervain Ct, Springfield, Virginia 22152 (United States); Rzadkiewicz, J. [National Centre for Nuclear Research, 05-400 Otwock (Poland); Seely, J. F. [Artep, Inc., 2922 Excelsior Springs Ct, Ellicott, Maryland 21042 (United States); Weber, B. V.; Schumer, J. W. [Naval Research Laboratory, Washington, DC 20375 (United States)

    2014-03-15

    The energy of the characteristic x-rays emitted by high atomic number atoms in a plasma that contains energetic electrons depends on the atom's ionization. For tungsten, the ionization energy shift of the L-lines has recently been used to diagnose the plasma's ionization; the change in energy of a K-line has been measured for iridium and observed for ytterbium. Here, we present detailed computations of the ionization energy shift to K-lines of these and an additional element, dysprosium; for these atoms, some K-lines nearly coincide in energy with K-edges of slightly lower Z atoms so that a change in transmission behind a K-edge filter betrays a change in energy. The ionization energy shift of such high-energy K-lines may enable a unique diagnostic when the plasma is inside an otherwise opaque enclosure such as hohlraums used on the National Ignition Facility.

  17. Spectroscopic diagnostics of active screen plasma nitriding processes: on the interplay of active screen and model probe plasmas

    Science.gov (United States)

    Hamann, S.; Börner, K.; Burlacov, I.; Spies, H.-J.; Röpcke, J.

    2015-09-01

    In a reactor used for active screen plasma nitriding (ASPN) the interplay of two plasma types, (i) the plasma of the cylindrical active screen driven in a pulsed dc mode (f = 1 kHz, 60% duty cycle) and (ii) the plasma at an internal model probe driven in a cw dc mode, ignited in a low pressure H2-N2 gas mixture (p = 3 mbar) containing small amounts of CH4 and CO2 have been studied by tunable diode laser infrared absorption (TDLAS) and optical emission spectroscopy (OES) techniques. Applying in situ TDLAS the evolution of the carbon containing precursors, CH4 and CO2, and of the reaction products, NH3, HCN, CO and H2O, has been monitored. The degree of dissociation of the carbon containing precursor molecules varied between 70% and 92%. The concentrations of the reaction products were found to be in the range 1012…1015 molecules cm-3. By analyzing the development of the molecular concentrations at changes of gas mixtures and plasma power values, it was found that (i) HCN and NH3 are the main products of plasma conversion in the case of methane admixture and (ii) CO, HCN and NH3 in the carbon dioxide case. The fragmentation efficiencies of methane and carbon dioxide (RF(CH4)  ≈  1…2   ×   1015 molecules J-1, RF(CO2)  ≈  0.5…1.0   ×   1016 molecules J-1) and the respective conversion efficiencies to the product molecules (R C(product) ≈ 1013-1015 molecules J-1) have been determined for different gas mixtures and plasma power values, while the influence of probe and screen plasmas, i.e. the phenomena caused by the interplay of both plasma sources, was analyzed. The additional usage of the plasma at the model probe has a sensitive influence on the generation of the reaction products, in particular that of NH3 and HCN. With the help of OES the rotational temperature of the screen plasma could be determined, which increases with power from 770 K to 950 K. Also with power the ionic component of nitrogen molecules, i

  18. V.U.V. plasma spectroscopy diagnostic of electron cyclotron resonance multicharged ion sources; Diagnostic de plasmas crees dans des sources d'ions multicharges a resonance cyclotronique electronique par spectroscopie V.U.V

    Energy Technology Data Exchange (ETDEWEB)

    Berreby, R

    1997-12-15

    To characterize the multicharged ions within the plasma of an E.C.R. ion source, the V.U.V. spectroscopy is used as a non invasive diagnostic of excited matter. In E.C.R.I. S. (electron cyclotron resonance ion source) electrons are heated and magnetically confined within the mirror machine to overcome the successive ionization potentials of the desired elements. As the electrons bounce inside the magnetic configuration in their gyration movement, they interact with the microwaves injected into the source at the resonance frequency. To enhance the performances in high charge states and extracted currents delivered by E.C.R.I.S., the fundamental parameters of the plasma created in these machines must be known. The goal of spectroscopic diagnostics in the V.U.V. range installed on the sources is to determine electron density and temperature on one hand, and the ionic densities and confinement time on the other hand. We used microchannel plates as detector on a 3 meter grazing incidence spectrometer equipped with a 600 lines/mm holographic grating. The calibration of the whole grating with detector was performed by two different methods. These are the branching ratio and charge exchange methods. Identification of lines emitted by a plasma, which gather the whole charge states of ions is necessary to make an exhaustive study of the plasma state. And finally, the determination of plasma parameters like electron density and temperature and ion densities and confinement times that uses theoretical models were the aim of this work. (author)

  19. Plasma diagnostics in gas metal arc welding by optical emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Valensi, F; Pellerin, S; Zielinska, S [GREMI, Universite d' Orleans (Site de Bourges)/CNRS, BP 4043, 18028 Bourges cedex (France); Boutaghane, A [Universite des Sciences et de la Technologie Houari Boumediene, Alger (Algeria); Dzierzega, K [Marian Smoluchowski Institute of Physics, Jagellonian University, Krakow (Poland); Pellerin, N [CNRS, UPR3079 CEMHTI, 1D av. de la Recherche Scientifique, 45071 Orleans cedex 2 (France); Briand, F, E-mail: flavien.valensi@laplace.univ-tsle.f, E-mail: stephane.pellerin@univ-orleans.f, E-mail: aboutaghane@yahoo.f, E-mail: krzycho@netmail.if.uj.edu.p, E-mail: sylwia.zielinska@airliquide.co, E-mail: nadia.pellerin@univ-orleans.f, E-mail: francis.briand@airliquide.co [CTAS-Air Liquide Welding, Saint Ouen l' Aumone, 95315 Cergy-Pontoise cedex (France)

    2010-11-03

    The plasma column in a metal inert gas welding process is investigated by optical emission spectroscopy and high-speed imaging. The concentration and repartition of iron vapours are measured and correlated with the plasma and electrode geometric configuration. Plasma temperatures and electron densities are also measured for each studied position in the plasma. The temperatures are calculated using two different methods, allowing validation of the local thermodynamic equilibrium state of the plasma. The results show a maximum temperature of 12 500 K in the upper part of the arc, away from the arc axis. The iron concentration reaches a maximum of 0.3% close to the anode and strongly decreases along both the vertical and radial directions. The plasma thermophysical properties, calculated from this plasma composition, are then discussed regarding the metal transfer mode.

  20. New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Hillesheim, J. C.; Peebles, W. A.; Rhodes, T. L.; Schmitz, L.; Carter, T. A. [Department of Physics and Astronomy, University of California, Los Angeles, Los Angeles, California 90095-1547 (United States); White, A. E. [Massachusetts Institute of Technology, Cambridge, Massachusetts 02139-4307 (United States)

    2010-10-15

    A novel multichannel, tunable Doppler backscattering (DBS)/reflectometry system has recently been developed and applied to a variety of DIII-D plasmas. Either DBS or reflectometry can be easily configured for use in a wide range of plasma conditions using a flexible quasi-optical antenna system. The multiple closely spaced channels, when combined with other fluctuation diagnostic systems, have opened up new measurements of plasma properties. For example, the toroidal and fine-scale radial structure of coherent plasma oscillations, such as geodesic acoustic modes, have been probed simultaneously in the core of high temperature plasmas by applying correlation analysis between two toroidally separated DBS systems, as well as within the multichannel array. When configured as a reflectometer, cross-correlation with electron cyclotron emission radiometry has uncovered detailed information regarding the crossphase relationship between density and temperature fluctuations. The density-temperature crossphase measurement yields insight into the physics of tokamak turbulence at a fundamental level that can be directly compared with predictions from nonlinear gyrokinetic simulations.

  1. New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak (invited).

    Science.gov (United States)

    Hillesheim, J C; Peebles, W A; Rhodes, T L; Schmitz, L; White, A E; Carter, T A

    2010-10-01

    A novel multichannel, tunable Doppler backscattering (DBS)/reflectometry system has recently been developed and applied to a variety of DIII-D plasmas. Either DBS or reflectometry can be easily configured for use in a wide range of plasma conditions using a flexible quasi-optical antenna system. The multiple closely spaced channels, when combined with other fluctuation diagnostic systems, have opened up new measurements of plasma properties. For example, the toroidal and fine-scale radial structure of coherent plasma oscillations, such as geodesic acoustic modes, have been probed simultaneously in the core of high temperature plasmas by applying correlation analysis between two toroidally separated DBS systems, as well as within the multichannel array. When configured as a reflectometer, cross-correlation with electron cyclotron emission radiometry has uncovered detailed information regarding the crossphase relationship between density and temperature fluctuations. The density-temperature crossphase measurement yields insight into the physics of tokamak turbulence at a fundamental level that can be directly compared with predictions from nonlinear gyrokinetic simulations.

  2. Quantum cascade laser based monitoring of CF2 radical concentration as a diagnostic tool of dielectric etching plasma processes

    Science.gov (United States)

    Hübner, M.; Lang, N.; Zimmermann, S.; Schulz, S. E.; Buchholtz, W.; Röpcke, J.; van Helden, J. H.

    2015-01-01

    Dielectric etching plasma processes for modern interlevel dielectrics become more and more complex by the introduction of new ultra low-k dielectrics. One challenge is the minimization of sidewall damage, while etching ultra low-k porous SiCOH by fluorocarbon plasmas. The optimization of this process requires a deeper understanding of the concentration of the CF2 radical, which acts as precursor in the polymerization of the etch sample surfaces. In an industrial dielectric etching plasma reactor, the CF2 radical was measured in situ using a continuous wave quantum cascade laser (cw-QCL) around 1106.2 cm-1. We measured Doppler-resolved ro-vibrational absorption lines and determined absolute densities using transitions in the ν3 fundamental band of CF2 with the aid of an improved simulation of the line strengths. We found that the CF2 radical concentration during the etching plasma process directly correlates to the layer structure of the etched wafer. Hence, this correlation can serve as a diagnostic tool of dielectric etching plasma processes. Applying QCL based absorption spectroscopy opens up the way for advanced process monitoring and etching controlling in semiconductor manufacturing.

  3. Fast particle-driven ion cyclotron emission (ICE) in tokamak plasmas and the case for an ICE diagnostic in ITER

    CERN Document Server

    McClements, K G; Dendy, R O; Carbajal, L; Chapman, S C; Cook, J W S; Harvey, R W; Heidbrink, W W; Pinches, S D

    2014-01-01

    Fast particle-driven waves in the ion cyclotron frequency range (ion cyclotron emission or ICE) have provided a valuable diagnostic of confined and escaping fast ions in many tokamaks. This is a passive, non-invasive diagnostic that would be compatible with the high radiation environment of deuterium-tritium plasmas in ITER, and could provide important information on fusion {\\alpha}-particles and beam ions in that device. In JET, ICE from confined fusion products scaled linearly with fusion reaction rate over six orders of magnitude and provided evidence that {\\alpha}-particle confinement was close to classical. In TFTR, ICE was observed from super-Alfv\\'enic {\\alpha}-particles in the plasma edge. The intensity of beam-driven ICE in DIII-D is more strongly correlated with drops in neutron rate during fishbone excitation than signals from more direct beam ion loss diagnostics. In ASDEX Upgrade ICE is produced by both super-Alfv\\'enic DD fusion products and sub-Alfv\\'enic deuterium beam ions.

  4. Langmuir probe Diagnostic for local parameter measurement in Magnetized Plasma using LabVIEW

    Directory of Open Access Journals (Sweden)

    Bijal Vara

    2014-03-01

    Full Text Available In recent years, plasma technology is used by Semiconductor, thin film industries for deposit layers, etching process and surface modification. So it is necessary to understanding internal plasma parameter. Langmuir probe is one of the simplest techniques which is used to measure wide range of plasma parameter like plasma potential, floating potential, electron temperature, electron energy distribution function (EEDF etc. Langmuir current voltage characteristic is obtained by varying bias voltage of the probe. LabVIEW is most powerful Microsoft window compatible software which is used to immediate data acquisition and analysis. In this paper describes analysis of Langmuir data using LabVIEW software which automatically measure I-V Plasma probe Characteristics and obtain EEDF of plasma.

  5. Mass number identification by Alfvén wave diagnostics in hydrogen and helium plasmas in TCABR

    Energy Technology Data Exchange (ETDEWEB)

    Puglia, P.G.P.; Elfimov, A.G., E-mail: elfimov@if.usp.br; Andriati, A.V.; Galvão, R.M.O.; Guimarães-Filho, Z.O.; Ronchi, G.; Ruchko, L.F.

    2016-03-11

    The mass number is obtained through the identification of the Global Alfvén (GA) wave resonances in ohmic plasma discharges in the TCABR tokamak. By comparing hydrogen and helium discharges, the composition of carbon, oxygen, and iron impurities is determined. The non-perturbative Alfvén diagnostic is used that is based on the excitation of GA waves by an external antenna fed by a low power generator, in the frequency band swept just below the minimum of the Alfvén wave continuum. Odd or even toroidal modes are excited by selecting the current phase in the two antenna modules separated by 180 degrees in the toroidal direction. The density profile, determined from cross analysis of reflectometer and interferometer data, shows impurity accumulation in the plasma core. - Highlights: • A non-perturbative Alfvén diagnostic is used to find the mass number in ohmic discharges in TCABR tokamak. • Global Alfvén waves are excited by an external antenna fed by a low power generator at the minimum of the Alfvén continuum. • Comparing hydrogen and helium discharges, the composition of carbon, oxygen and iron impurities is determined. • The density profile defined reflectometer and interferometer data shows impurity accumulation in the plasma core.

  6. Energy shifts of K- and L-lines as spectroscopic diagnostic of Z-pinch plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Słabkowska, K.; Szymańska, E.; Polasik, M. [Faculty of Chemistry, Nicolaus Copernicus University, 87-100 Toruń (Poland); Rzadkiewicz, J. [National Centre for Nuclear Research, 05-400 Otwock (Poland); Syrocki, Ł. [Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, 87-100 Toruń (Poland); Pereira, N. R., E-mail: ninorpereira@gmail.com [Ecopulse, Inc., Springfield, VA, 22152 (United States)

    2014-12-15

    Ultrafast molybdenum wire implosions on the Z machine at Sandia produce intense pulses of multi-keV x-rays from partially ionized plasmas. The most intense radiation comes from a hot, dense core of thermal plasma in ionization equilibrium with Mo ionized to within the L-shell. Non-thermal, energetic electrons in the plasma generate Kα and Kβ radiation, whose energy is affected by Mo’s ionization state, and therefore on the plasma temperature. Based on an extensive series of recent computations on this effect, we recalculate the pinch’ Mo x-ray spectrum, with reasonable results.

  7. Description of the plasma diagnostics package (PDP) for the OSS-1 Shuttle mission and JSC plasma chamber test in conjunction with the fast pulse electron gun (FPEG)

    Science.gov (United States)

    Shawhan, S. D.

    1982-01-01

    The objectives, equipment, and techniques for the plasma diagnostics package (PDP) carried by the OSS-1 instrument payload of the STS-4 and scheduled for the Spacelab-2 mission are described. The goals of the first flight were to examine the Orbiter-magnetoplasma interactions by measuring the electric and magnetic field strengths, the ionized particle wakes, and the generated waves. The RMS was employed to lift the unit out of the bay in order to allow characterization of the fields, EM interference, and plasma contamination within 15 m of the Orbiter. The PDP will also be used to examine plasma depletion, chemical reaction rates, waves, and energized plasma produced by firing of the Orbiter thrusters. Operation of the PDP was carried out in the NASA Space Environment Simulation Laboratory test chamber, where the PDP was used to assay the fields, fluxes, wave amplitudes, and particle energy spectra. The PDP instrumentation is also capable of detecting thermal ions, thermal electrons suprathermal particles, VHF/UHF EMI levels, and the S-band field strength.

  8. Gaseous electron multiplier-based soft x-ray plasma diagnostics development: Preliminary tests at ASDEX Upgrade

    Science.gov (United States)

    Chernyshova, M.; Malinowski, K.; Czarski, T.; Wojeński, A.; Vezinet, D.; Poźniak, K. T.; Kasprowicz, G.; Mazon, D.; Jardin, A.; Herrmann, A.; Kowalska-Strzeciwilk, E.; Krawczyk, R.; Kolasiński, P.; Zabołotny, W.; Zienkiewicz, P.

    2016-11-01

    A Gaseous Electron Multiplier (GEM)-based detector is being developed for soft X-ray diagnostics on tokamaks. Its main goal is to facilitate transport studies of impurities like tungsten. Such studies are very relevant to ITER, where the excessive accumulation of impurities in the plasma core should be avoided. This contribution provides details of the preliminary tests at ASDEX Upgrade (AUG) with a focus on the most important aspects for detector operation in harsh radiation environment. It was shown that both spatially and spectrally resolved data could be collected, in a reasonable agreement with other AUG diagnostics. Contributions to the GEM signal include also hard X-rays, gammas, and neutrons. First simulations of the effect of high-energy photons have helped understanding these contributions.

  9. Gaseous electron multiplier-based soft x-ray plasma diagnostics development: Preliminary tests at ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Chernyshova, M., E-mail: maryna.chernyshova@ipplm.pl; Malinowski, K.; Czarski, T.; Kowalska-Strzęciwilk, E. [Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw (Poland); Wojeński, A.; Poźniak, K. T.; Kasprowicz, G.; Krawczyk, R.; Kolasiński, P.; Zabołotny, W.; Zienkiewicz, P. [Institute of Electronic Systems, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw (Poland); Vezinet, D.; Herrmann, A. [Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Mazon, D.; Jardin, A. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France)

    2016-11-15

    A Gaseous Electron Multiplier (GEM)-based detector is being developed for soft X-ray diagnostics on tokamaks. Its main goal is to facilitate transport studies of impurities like tungsten. Such studies are very relevant to ITER, where the excessive accumulation of impurities in the plasma core should be avoided. This contribution provides details of the preliminary tests at ASDEX Upgrade (AUG) with a focus on the most important aspects for detector operation in harsh radiation environment. It was shown that both spatially and spectrally resolved data could be collected, in a reasonable agreement with other AUG diagnostics. Contributions to the GEM signal include also hard X-rays, gammas, and neutrons. First simulations of the effect of high-energy photons have helped understanding these contributions.

  10. Optical diagnostics of reactive species in atmospheric-pressure nonthermal plasma

    Science.gov (United States)

    Ono, Ryo

    2016-03-01

    This paper reviews optical measurements of reactive species in atmospheric-pressure nonthermal plasmas: streamer discharge, dielectric barrier discharge (DBD), plasma jet, and plasma-assisted ignition and combustion. Measurements of OH, O, N, {{\\text{O}}3} , NO, {{\\text{N}}2} (A, B, C), {{\\text{O}}2} (a, b), {{\\text{N}}2}(v) , {{\\text{O}}2}(v) , He*, Ar*, \\text{N}2+ , CH, and CH2O by laser-induced fluorescence, absorption, optical emission spectroscopy, and coherent anti-Stokes Raman scattering methods are included. Reactive species measurement in low-frequency (\\cong 1 Hz) pulsed streamer discharge is introduced, and reactive species production and reaction processes indicated by these measurements are described in detail. Measurements in high-frequency DBD, atmospheric-pressure diffuse discharge, and dc corona discharge are described. Measurements in plasma jets are also reviewed: rf plasma jets, kHz plasma jets, and additional plasma jets. Finally, measurements in plasma-assisted ignition and combustion are described and reviewed in addition to measurements in conventional spark ignition. A comprehensive list of the reviewed measurements is provided.

  11. Size-based molecular diagnostics using plasma DNA for noninvasive prenatal testing

    NARCIS (Netherlands)

    Yu, S.C.; Chan, K.C.; Zheng, Y.W.; Jiang, P.; Liao, G.J.; Sun, H; Akolekar, R.; Leung, T.Y.; Go, A.T.; Vugt, J.M.G. van; Minekawa, R.; Oudejans, C.B.; Nicolaides, K.H.; Chiu, R.W.; Lo, Y.M.

    2014-01-01

    Noninvasive prenatal testing using fetal DNA in maternal plasma is an actively researched area. The current generation of tests using massively parallel sequencing is based on counting plasma DNA sequences originating from different genomic regions. In this study, we explored a different approach th

  12. Identification of plasma microRNAs as new potential biomarkers with high diagnostic power in human cutaneous melanoma.

    Science.gov (United States)

    Fogli, Stefano; Polini, Beatrice; Carpi, Sara; Pardini, Barbara; Naccarati, Alessio; Dubbini, Nevio; Lanza, Maria; Breschi, Maria Cristina; Romanini, Antonella; Nieri, Paola

    2017-05-01

    Melanoma is a devastating disease with few therapeutic options in the advanced stage and with the urgent need of reliable biomarkers for early detection. In this context, circulating microRNAs are raising great interest as diagnostic biomarkers. We analyzed the expression profiles of 21 selected microRNAs in plasma samples from melanoma patients and healthy donors to identify potential diagnostic biomarkers. Data analysis was performed using global mean normalization and NormFinder algorithm. Linear regression followed by receiver operating characteristic analyses was carried out to evaluate whether selected plasma miRNAs were able to discriminate between cases and controls. We found five microRNAs that were differently expressed among cases and controls after Bonferroni correction for multiple testing. Specifically, miR-15b-5p, miR-149-3p, and miR-150-5p were up-regulated in plasma of melanoma patients compared with healthy controls, while miR-193a-3p and miR-524-5p were down-regulated. Receiver operating characteristic analyses of these selected microRNAs provided area under the receiver operating characteristic curve values ranging from 0.80 to 0.95. Diagnostic value of microRNAs is improved when considering the combination of miR-149-3p, miR-150-5p, and miR-193a-3p. The triple classifier had a high capacity to discriminate between melanoma patients and healthy controls, making it suitable to be used in early melanoma diagnosis.

  13. Intermediate frequency band digitized high dynamic range radiometer system for plasma diagnostics and real-time Tokamak control

    Science.gov (United States)

    Bongers, W. A.; van Beveren, V.; Thoen, D. J.; Nuij, P. J. W. M.; de Baar, M. R.; Donné, A. J. H.; Westerhof, E.; Goede, A. P. H.; Krijger, B.; van den Berg, M. A.; Kantor, M.; Graswinckel, M. F.; Hennen, B. A.; Schüller, F. C.

    2011-06-01

    An intermediate frequency (IF) band digitizing radiometer system in the 100-200 GHz frequency range has been developed for Tokamak diagnostics and control, and other fields of research which require a high flexibility in frequency resolution combined with a large bandwidth and the retrieval of the full wave information of the mm-wave signals under investigation. The system is based on directly digitizing the IF band after down conversion. The enabling technology consists of a fast multi-giga sample analog to digital converter that has recently become available. Field programmable gate arrays (FPGA) are implemented to accomplish versatile real-time data analysis. A prototype system has been developed and tested and its performance has been compared with conventional electron cyclotron emission (ECE) spectrometer systems. On the TEXTOR Tokamak a proof of principle shows that ECE, together with high power injected and scattered radiation, becomes amenable to measurement by this device. In particular, its capability to measure the phase of coherent signals in the spectrum offers important advantages in diagnostics and control. One case developed in detail employs the FPGA in real-time fast Fourier transform (FFT) and additional signal processing. The major benefit of such a FFT-based system is the real-time trade-off that can be made between frequency and time resolution. For ECE diagnostics this corresponds to a flexible spatial resolution in the plasma, with potential application in smart sensing of plasma instabilities such as the neoclassical tearing mode (NTM) and sawtooth instabilities. The flexible resolution would allow for the measurement of the full mode content of plasma instabilities contained within the system bandwidth.

  14. Intermediate frequency band digitized high dynamic range radiometer system for plasma diagnostics and real-time Tokamak control

    Energy Technology Data Exchange (ETDEWEB)

    Bongers, W. A.; Beveren, V. van; Westerhof, E.; Goede, A. P. H.; Krijger, B.; Berg, M. A. van den; Graswinckel, M. F.; Schueller, F. C. [FOM-Institute for Plasma Physics Rijnhuizen, Association EURATOM-FOM, Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Thoen, D. J. [Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft (Netherlands); Nuij, P. J. W. M. [Eindhoven University of Technology, Control Systems Technology Group, and Applied Physics Department, PO Box 513, NL-5600 MB Eindhoven (Netherlands); Baar, M. R. de; Donne, A. J. H.; Hennen, B. A. [FOM-Institute for Plasma Physics Rijnhuizen, Association EURATOM-FOM, Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Eindhoven University of Technology, Control Systems Technology Group, and Applied Physics Department, PO Box 513, NL-5600 MB Eindhoven (Netherlands); Kantor, M. [FOM-Institute for Plasma Physics Rijnhuizen, Association EURATOM-FOM, Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Forschungszentrum Juelich GMBH, Institute of Energy and Climate research, Plasma Physics, Association EURATOM-FZJ, Trilateral Euregio Cluster, 52425 Juelich (Germany); Ioffe Institute, RAS, Saint-Petersburg, 195256 (Russian Federation)

    2011-06-15

    An intermediate frequency (IF) band digitizing radiometer system in the 100-200 GHz frequency range has been developed for Tokamak diagnostics and control, and other fields of research which require a high flexibility in frequency resolution combined with a large bandwidth and the retrieval of the full wave information of the mm-wave signals under investigation. The system is based on directly digitizing the IF band after down conversion. The enabling technology consists of a fast multi-giga sample analog to digital converter that has recently become available. Field programmable gate arrays (FPGA) are implemented to accomplish versatile real-time data analysis. A prototype system has been developed and tested and its performance has been compared with conventional electron cyclotron emission (ECE) spectrometer systems. On the TEXTOR Tokamak a proof of principle shows that ECE, together with high power injected and scattered radiation, becomes amenable to measurement by this device. In particular, its capability to measure the phase of coherent signals in the spectrum offers important advantages in diagnostics and control. One case developed in detail employs the FPGA in real-time fast Fourier transform (FFT) and additional signal processing. The major benefit of such a FFT-based system is the real-time trade-off that can be made between frequency and time resolution. For ECE diagnostics this corresponds to a flexible spatial resolution in the plasma, with potential application in smart sensing of plasma instabilities such as the neoclassical tearing mode (NTM) and sawtooth instabilities. The flexible resolution would allow for the measurement of the full mode content of plasma instabilities contained within the system bandwidth.

  15. X-ray plasma diagnostics for totally and partially photoionized plasmas such as warm absorbers in agn

    Directory of Open Access Journals (Sweden)

    Delphine Porquet

    2000-01-01

    Full Text Available Gracias a la nueva generaci on de satelites de rayos-X, como Chandra y XMM, se pueden obtener espectros de alta sensibilidad y resoluci on. En particular, se pueden separar las tres l neas m as intensas (resonantes, de intercombinaci on y prohibidas de iones de baja carga (baja Z como el He, en plasmas no solares. Basados en estas tres l neas, presentamos diagn osticos para densidad, procesos de ionizaci on y temperatura totalmente o parcialmente ionizados por fotoionizaci on. Estos poderosos diagn osticos pueden ser usados en plasmas calientes como los de AGN, galaxias con brotes de formaci on estelar, binarias de rayos-X, etc. En parti- cular, pueden ser usados en los absorbedores tibios que se ven en AGN (Porquet & Dubau 2000, que son herramientas importantes para entender las regiones centrales de diferentes tipos de AGN (Seyferts 1 y 2 y cuasares de bajo y alto corrimiento al rojo.

  16. Single-shot, ultrafast diagnostics of light-speed plasma structures and accelerating GeV electrons

    Science.gov (United States)

    Chang, Yen-Yu; Shaw, Joseph M.; Welch, James; Weichman, Kathleen; Hannasch, Andrea; LaBerge, Maxwell; Henderson, Watson; Zgadzaj, Rafal; Bernstein, Aaron; Downer, Mike

    2017-03-01

    We have experimentally demonstrated ultrafast diagnostics to visualize the laser wakefield acceleration process in a single-shot mode. We measured the Faraday rotation of a probe pulse due to the magnetic field induced by GeV electrons in low-density plasmas. In addition, we improved the temporal resolution of Frequency Domain Streak Camera (FDSC) to ˜10 fs by broadening the bandwidth of the probe beam, enabling visualization of the bubble dynamics. A prototype experiment using the broad bandwidth FDSC was performed.

  17. Radial profile measurements of plasma pressure-like fluctuations with the heavy ion beam diagnostic on the tokamak ISTTOK

    Energy Technology Data Exchange (ETDEWEB)

    Henriques, R. B., E-mail: rhenriques@ipfn.ist.utl.pt; Malaquias, A.; Nedzelskiy, I. S.; Silva, C.; Coelho, R.; Figueiredo, H.; Fernandes, H. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa (Portugal)

    2014-11-15

    The Heavy Ion Beam Diagnostic (HIBD) on the tokamak ISTTOK (Instituto Superior Técnico TOKamak) has been modified, in terms of signal conditioning, to measure the local fluctuations of the n{sub e}σ{sub 1,2}(T{sub e}) product (plasma density times the effective ionization cross-section) along the tokamak minor diameter, in 12 sample volumes in the range of −0.7a < r < 0.7a, with a maximum delay time of 1 μs. The corresponding signals show high correlation with the magnetic Mirnov coils in the characteristic MHD frequency range of ISTTOK plasmas and enable the identification of tearing modes. This paper describes the HIBD signal conditioning system and presents a preliminary analysis of the radial profile measurements of local n{sub e}σ{sub 1,2}(T{sub e}) fluctuations.

  18. High sensitivity far infrared laser diagnostics for the C-2U advanced beam-driven field-reversed configuration plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Deng, B. H., E-mail: bdeng@trialphaenergy.com; Beall, M.; Schroeder, J.; Settles, G.; Feng, P.; Kinley, J. S.; Gota, H.; Thompson, M. C. [Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688 (United States)

    2016-11-15

    A high sensitivity multi-channel far infrared laser diagnostics with switchable interferometry and polarimetry operation modes for the advanced neutral beam-driven C-2U field-reversed configuration (FRC) plasmas is described. The interferometer achieved superior resolution of 1 × 10{sup 16} m{sup −2} at >1.5 MHz bandwidth, illustrated by measurement of small amplitude high frequency fluctuations. The polarimetry achieved 0.04° instrument resolution and 0.1° actual resolution in the challenging high density gradient environment with >0.5 MHz bandwidth, making it suitable for weak internal magnetic field measurements in the C-2U plasmas, where the maximum Faraday rotation angle is less than 1°. The polarimetry resolution data is analyzed, and high resolution Faraday rotation data in C-2U is presented together with direct evidences of field reversal in FRC magnetic structure obtained for the first time by a non-perturbative method.

  19. Betatron radiation based diagnostics for plasma wakefield accelerated electron beams at the SPARC-LAB test facility

    Energy Technology Data Exchange (ETDEWEB)

    Shpakov, V.; Anania, M.P.; Biagioni, A.; Chiadroni, E. [INFN - LNF, via Enrico Fermi 40, 00044 Frascati (Italy); Cianchi, A. [INFN - LNF, via Enrico Fermi 40, 00044 Frascati (Italy); “Tor Vergata” University, via della Ricerca Scientifica 1, 00133 Rome (Italy); Curcio, A. [INFN - LNF, via Enrico Fermi 40, 00044 Frascati (Italy); Dabagov, S. [INFN - LNF, via Enrico Fermi 40, 00044 Frascati (Italy); P.N. Lebedev Physical Institute RAS, Leninskiy Prospekt 53, 119991 Moscow (Russian Federation); NRNU “MEPhI”, Kashirskoe highway 31, 115409 Moscow (Russian Federation); Ferrario, M.; Filippi, F. [INFN - LNF, via Enrico Fermi 40, 00044 Frascati (Italy); Marocchino, A. [Dipartimento SBAI Universitá di Roma ‘La Sapienza’, via Antonio Scarpa 14/16, 00161 Rome (Italy); Paroli, B. [INFN - MI, via Celoria 16, 20133 Milan (Italy); Pompili, R. [INFN - LNF, via Enrico Fermi 40, 00044 Frascati (Italy); Rossi, A.R. [INFN - MI, via Celoria 16, 20133 Milan (Italy); Zigler, A. [Racah Institute of Physics Hebrew University of Jerusalem (Israel)

    2016-09-01

    Recent progress with wake-field acceleration has shown a great potential in providing high gradient acceleration fields, while the quality of the beams remains relatively poor. Precise knowledge of the beam size at the exit from the plasma and matching conditions for the externally injected beams are the key for improvement of beam quality. Betatron radiation emitted by the beam during acceleration in the plasma is a powerful tool for the transverse beam size measurement, being also non-intercepting. In this work we report on the technical solutions chosen at SPARC-LAB for such diagnostics tool, along with expected parameters of betatron radiation. - Highlights: • The betatron radiation parameters in SPARC-LAB wakefiled experiments were studied. • The differences with betatron radiation in other wake-field experiments were highlighted. • The solution for betatron radiation detection was investigated.

  20. High sensitivity far infrared laser diagnostics for the C-2U advanced beam-driven field-reversed configuration plasmas

    Science.gov (United States)

    Deng, B. H.; Beall, M.; Schroeder, J.; Settles, G.; Feng, P.; Kinley, J. S.; Gota, H.; Thompson, M. C.

    2016-11-01

    A high sensitivity multi-channel far infrared laser diagnostics with switchable interferometry and polarimetry operation modes for the advanced neutral beam-driven C-2U field-reversed configuration (FRC) plasmas is described. The interferometer achieved superior resolution of 1 × 1016 m-2 at >1.5 MHz bandwidth, illustrated by measurement of small amplitude high frequency fluctuations. The polarimetry achieved 0.04° instrument resolution and 0.1° actual resolution in the challenging high density gradient environment with >0.5 MHz bandwidth, making it suitable for weak internal magnetic field measurements in the C-2U plasmas, where the maximum Faraday rotation angle is less than 1°. The polarimetry resolution data is analyzed, and high resolution Faraday rotation data in C-2U is presented together with direct evidences of field reversal in FRC magnetic structure obtained for the first time by a non-perturbative method.

  1. Physics-based investigation of negative ion behavior in a negative-ion-rich plasma using integrated diagnostics

    Science.gov (United States)

    Tsumori, K.; Takeiri, Y.; Ikeda, K.; Nakano, H.; Geng, S.; Kisaki, M.; Nagaoka, K.; Tokuzawa, T.; Wada, M.; Sasaki, K.; Nishiyama, S.; Goto, M.; Osakabe, M.

    2017-08-01

    Total power of 16 MW has been successfully delivered to the plasma confined in the Large Helical Device (LHD) from three Neutral Beam Injectors (NBIs) equipped with negative hydrogen (H-) ion sources. However, the detailed mechanisms from production through extraction of H- ions are still yet to be clarified and a similar size ion source on an independent acceleration test bench called Research and development Negative Ion Source (RNIS) serves as the facility to study physics related to H- production and transport for further improvement of NBI. The production of negative-ion-rich plasma and the H- ions behavior in the beam extraction region in RNIS is being investigated by employing an integrated diagnostic system. Flow patterns of electrons, positive ions and H- ions in the extraction region are described in a two-dimensional map. The measured flow patterns indicate the existence a stagnation region, where the H- flow changes the direction at a distance about 20 mm from the plasma grid. The pattern also suggested the H- flow originated from plasma grid (PG) surface that turned back toward extraction apertures. The turning region seems formed by a layer of combined magnetic field produced by the magnetic filter field and the Electron-Deflection Magnetic (EDM) field created by magnets installed in the extraction electrode.

  2. Diagnostics of a charge breeder electron cyclotron resonance ion source helium plasma with the injection of ^{23}Na^{1+} ions

    Directory of Open Access Journals (Sweden)

    O. Tarvainen

    2016-05-01

    Full Text Available This work describes the utilization of an injected ^{23}Na^{1+} ion beam as a diagnostics of the helium plasma of a charge breeder electron cyclotron resonance ion source. The obtained data allows estimating the upper limit for the ion-ion collision mean-free path of the incident sodium ions, the lower limit of ion-ion collision frequencies for all charge states of the sodium ions and the lower limit of the helium plasma density. The ion-ion collision frequencies of high charge state ions are shown to be at least on the order of 1–10 MHz and the plasma density is estimated to be on the order of 10^{11}  cm^{-3} or higher. The experimental results are compared to simulations of the ^{23}Na^{1+} capture into the helium plasma. The results indicate that the lower breeding efficiency of light ions in comparison to heavier elements is probably due to different capture efficiencies in which the in-flight ionization of the incident 1+ ions plays a vital role.

  3. The Diagnostics Of Hydrogen-Cesium Plasma Using Fully Relativistic Electron Impact Cross Sections

    Science.gov (United States)

    Priti, Priti; Dipti, Dipti; Gangwar, Reetesh; Srivastava, Rajesh

    2016-10-01

    Electron excitation cross-sections and rate coefficients have been calculated using fully relativistic distorted wave theory for several fine-structure transitions from the ground as well as excited states of cesium atom in the wide range of incident electron energy. These processes play dominant role in low pressure hydrogen-cesium plasma relevant to the negative ion based neutral beam injectors for the ITER project. The calculated cross-sections are used to construct a reliable collisional radiative (CR) model to characterize the hydrogen-cesium plasma. The calculated plasma parameters are compared with the available experimental and theoretical results.

  4. Diagnostic en température et en densité d’un plasma LIBS.

    OpenAIRE

    MENNI, Meriem

    2016-01-01

    La spectroscopie d’émission du plasma induit par laser conduit à la technique LIBS. Acronyme qui signifie Laser induced Breakdown Spectroscopy. Dans cette technique, un petit plasma est généré en focalisant une impulsion laser sur un échantillon d’intérêt, qu’il soit solide, liquide ou gazeux. L’analyse spectrale de la lumière émise par le plasma permet d’identifier et de quantifier les éléments contenus initialement dans le volume ablaté de l’échan...

  5. Acoustic Diagnostics of Plasma Channels Induced by Intense Femtosecond Laser Pulses in Air

    Institute of Scientific and Technical Information of China (English)

    HAO Zuo-Qiang; WEI Zhi-Yi; YU Jin; ZHANG Jie; LI Yu-Tong; YUAN Xiao-Hui; ZHENG Zhi-Yuan; WANG Peng; WANG Zhao-Hua; LING Wei-Jun

    2005-01-01

    @@ Long plasma channels induced by femtosecond laser pulses in air are diagnosed using the sonographic method. By detecting the sound signals along the channels, the length and the electron density of the channels are measured.

  6. Plasma diagnostics from self-absorbed doublet lines in laser-induced breakdown spectroscopy

    Science.gov (United States)

    D'Angelo, C. A.; Garcimuño, M.; Díaz Pace, D. M.; Bertuccelli, G.

    2015-10-01

    In this paper, a generalized approach is developed and applied for plasma characterization and quantitative purposes in laser-induced breakdown spectroscopy (LIBS) experiences by employing a selected pair of spectral lines belonging to the same multiplet. It is based on the comparison between experimental ratios of line parameters and the theoretical calculus obtained under the framework of a homogeneous plasma in local thermodynamic equilibrium. The applicability of the method was illustrated by using the atomic resonance transitions 279.55-280.27 nm of Mg II, which are usually detected in laser-induced plasma (LIP) during laser ablation of many kinds of targets. The laser induced plasmas were produced using a Nd:YAG laser from a pressed pellet of powdered calcium hydroxide with a concentration of 300 ppm of Mg. The experimental ratios for peak intensities, total intensities and Stark widths were obtained for different time windows and matched to the theoretical calculus. The temperature and the electron density of the plasma, as well as the Mg columnar density (the atom/ion concentration times the length of the plasma along the line-of-sight), were determined. The results were interpreted under the employed approach.

  7. Concentration and Methylation of Cell-Free DNA from Blood Plasma as Diagnostic Markers of Renal Cancer

    Science.gov (United States)

    Tsyba, Liudmyla; Onyshchenko, Kateryna; Kashparova, Olena; Nikolaienko, Oleksii; Panasenko, Grigory; Vozianov, Sergii; Romanenko, Alina; Rynditch, Alla

    2016-01-01

    The critical point for successful treatment of cancer is diagnosis at early stages of tumor development. Cancer cell-specific methylated DNA has been found in the blood of cancer patients, indicating that cell-free DNA (cfDNA) circulating in the blood is a convenient tumor-associated DNA marker. Therefore methylated cfDNA can be used as a minimally invasive diagnostic marker. We analysed the concentration of plasma cfDNA and methylation of six tumor suppressor genes in samples of 27 patients with renal cancer and 15 healthy donors as controls. The cfDNA concentrations in samples from cancer patients and healthy donors was measured using two different methods, the SYBR Green I fluorescence test and quantitative real-time PCR. Both methods revealed a statistically significant increase of cfDNA concentrations in cancer patients. Hypermethylation on cfDNA was detected for the LRRC3B (74.1%), APC (51.9%), FHIT (55.6%), and RASSF1 (62.9%) genes in patients with renal cancer. Promoter methylation of VHL and ITGA9 genes was not found on cfDNA. Our results confirmed that the cfDNA level and methylation of CpG islands of RASSF1A, FHIT, and APC genes in blood plasma can be used as noninvasive diagnostic markers of cancer.

  8. Concentration and Methylation of Cell-Free DNA from Blood Plasma as Diagnostic Markers of Renal Cancer.

    Science.gov (United States)

    Skrypkina, Inessa; Tsyba, Liudmyla; Onyshchenko, Kateryna; Morderer, Dmytro; Kashparova, Olena; Nikolaienko, Oleksii; Panasenko, Grigory; Vozianov, Sergii; Romanenko, Alina; Rynditch, Alla

    2016-01-01

    The critical point for successful treatment of cancer is diagnosis at early stages of tumor development. Cancer cell-specific methylated DNA has been found in the blood of cancer patients, indicating that cell-free DNA (cfDNA) circulating in the blood is a convenient tumor-associated DNA marker. Therefore methylated cfDNA can be used as a minimally invasive diagnostic marker. We analysed the concentration of plasma cfDNA and methylation of six tumor suppressor genes in samples of 27 patients with renal cancer and 15 healthy donors as controls. The cfDNA concentrations in samples from cancer patients and healthy donors was measured using two different methods, the SYBR Green I fluorescence test and quantitative real-time PCR. Both methods revealed a statistically significant increase of cfDNA concentrations in cancer patients. Hypermethylation on cfDNA was detected for the LRRC3B (74.1%), APC (51.9%), FHIT (55.6%), and RASSF1 (62.9%) genes in patients with renal cancer. Promoter methylation of VHL and ITGA9 genes was not found on cfDNA. Our results confirmed that the cfDNA level and methylation of CpG islands of RASSF1A, FHIT, and APC genes in blood plasma can be used as noninvasive diagnostic markers of cancer.

  9. Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic.

    Science.gov (United States)

    Swadling, G F; Ross, J S; Datte, P; Moody, J; Divol, L; Jones, O; Landen, O

    2016-11-01

    An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause "blanking" (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ∼8 J cm(-2). This is significantly above the expected threshold for the onset of "blanking" effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate "blanking." Estimates suggest that an areal density of 10(19) cm(-2) Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

  10. Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic

    Science.gov (United States)

    Swadling, G. F.; Ross, J. S.; Datte, P.; Moody, J.; Divol, L.; Jones, O.; Landen, O.

    2016-11-01

    An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause "blanking" (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ˜8 J cm-2. This is significantly above the expected threshold for the onset of "blanking" effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate "blanking." Estimates suggest that an areal density of 1019 cm-2 Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

  11. Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Swadling, G. F.; Ross, J. S.; Datte, P.; Moody, J.; Divol, L.; Jones, O.; Landen, O. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2016-11-15

    An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause “blanking” (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ∼8 J cm{sup −2}. This is significantly above the expected threshold for the onset of “blanking” effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate “blanking.” Estimates suggest that an areal density of 10{sup 19} cm{sup −2} Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

  12. [Plasma copeptin--a multi-purpose diagnostic tool for clinicians?].

    Science.gov (United States)

    Koistinen, Heikki

    2012-01-01

    Measurement of antidiuretic hormone (ADH) is utilized in the diagnosis of hyponatremia and polyuria. However, determination of ADH is slow, and results may be unreliable. Copeptin is a glycopeptide of 39 amino acid residues that is cleaved from a precursor of ADH and secreted to the circulation in an equimolar manner with ADH. Determination of the copeptin level is quick and reliable, and improves the diagnostics of osmotic disorders. Copeptin seems to be a promising diagnostic tool also in acute coronary syndrome and may have prognostic significance in cardiac insufficiency, stroke or septicaemia, too.

  13. Plasma lysosphingomyelin demonstrates great potential as a diagnostic biomarker for Niemann-Pick disease type C in a retrospective study.

    Directory of Open Access Journals (Sweden)

    Richard W D Welford

    Full Text Available Niemann-Pick disease type C (NP-C is a devastating, neurovisceral lysosomal storage disorder which is characterised by variable manifestation of visceral signs, progressive neuropsychiatric deterioration and premature death, caused by mutations in the NPC1 and NPC2 genes. Due to the complexity of diagnosis and the availability of an approved therapy in the EU, improved detection of NP-C may have a huge impact on future disease management. At the cellular level dysfunction or deficiency of either the NPC1 or NPC2 protein leads to a complex intracellular endosomal/lysosomal trafficking defect, and organ specific patterns of sphingolipid accumulation. Lysosphingolipids have been shown to be excellent biomarkers of sphingolipidosis in several enzyme deficient lysosomal storage disorders. Additionally, in a recent study the lysosphingolipids, lysosphingomyelin (SPC and glucosylsphingosine (GlcSph, appeared to be elevated in the plasma of three adult NP-C patients. In order to investigate the clinical utility of SPC and GlcSph as diagnostic markers, an in-depth fit for purpose biomarker assay validation for measurement of these biomarkers in plasma by liquid chromatography-tandem mass spectrometry was performed. Plasma SPC and GlcSph are stable and can be measured accurately, precisely and reproducibly. In a retrospective analysis of 57 NP-C patients and 70 control subjects, median plasma SPC and GlcSph were significantly elevated in NP-C by 2.8-fold and 1.4-fold respectively. For miglustat-naïve NP-C patients, aged 2-50 years, the area under the ROC curve was 0.999 for SPC and 0.776 for GlcSph. Plasma GlcSph did not correlate with SPC levels in NP-C patients. The data indicate excellent potential for the use of lysosphingomyelin in NP-C diagnosis, where it could be used to identify NP-C patients for confirmatory genetic testing.

  14. Diagnostics and analyses of decay process in laser produced tetrakis(dimethyl-amino)ethylene plasma

    Science.gov (United States)

    Ding, Guowen; Scharer, John E.; Kelly, Kurt L.

    2001-01-01

    A large volume (hundreds of cm3) plasma is created by a 193 nm laser ionizing an organic vapor, tetrakis(dimethyl-amino)ethylene (TMAE). The plasma is characterized as high electron density (1013-1012 cm-3) and low electron temperature (˜0.1 eV). To investigate the plasma decay processes, a fast Langmuir probe technique is developed, including detailed considerations of probe structure, probe surface cleaning, shielding, frequency response of the detection system, physical processes in probe measurement, dummy probe corrections as well as noise analysis. The mechanisms for the plasma decay are studied and a delayed ionization process following the laser pulse is found to be important. This mechanism is also supported by optical emission measurements which show that nitrogen enhances the delayed emission from TMAE plasma. A model combining electron-ion recombination and delayed ionization is utilized together with experimental results to order the terms and calculate the relaxation times for delayed ionization. The relaxation times are longer for lower TMAE pressures and lower electron densities.

  15. Imaging diagnostics of pulsed plasma discharges in saline generated with various sharp pin powered electrodes

    Science.gov (United States)

    Asimakoulas, L.; Karim, M. L.; Dostal, L.; Krcma, F.; Graham, W. G.; Field, T. A.

    2016-09-01

    Plasmas formed by 1 ms pulses of between 180 and 300 V applied to sharp pin-like electrodes immersed in saline solution have been imaged with a Photron SA-X2 fast framing camera and an Andor iStar 510 ICCD camera. Stainless steel, Tungsten and Gold electrodes were investigated with tip diameters of 30 μm, 1 μm and volume, which appears to move about, but remains close to the tip. In the case of Tungsten with higher voltages or longer pulses the tip of the needle can heat up to incandescent temperatures. At higher voltages shock wave fronts appear to be observed as the vapour layer collapses at the end of the voltage pulse. Backlighting and no lighting to observe bubble/vapour layer formation and emission due to plasma formation were employed. Sometimes at higher voltages a thicker vapour layer engulfs the tip and no plasma emission/current is observed.

  16. New Microwave Diagnostic Theory for Measurement of Electron Density in Atmospheric Plasmas

    Institute of Scientific and Technical Information of China (English)

    ZHANG Shu; HU Xi-Wei

    2005-01-01

    @@ We present the phase shift of an electromagnetic wave passing through an atmospheric plasma layer. In this kind of plasma, the phase shift depends not only on the line average electron density and layer width, but also on the electron-neutral collision frequency. Since the collision frequency is close to or even larger than the incident microwave frequency, a one-dimensional code for the numerical solution of the wave equation with full time and space variables is established to give the phase shift. When the width and the pressure (hence the electron-neutral collision frequency) are known, the measurement of phase shift will uniquely determine the line average electrons density in an atmospheric plasma.

  17. Diagnostics of low and atmospheric pressure plasmas by means of mass spectrometry

    CERN Document Server

    Benedikt, Jan; von Keudell, Achim

    2011-01-01

    The knowledge of absolute fluxes of reactive species such as radicals or energetic ions to the surface is crucial for understanding the growth or etching of thin films. These species have due to their high reactivity very low densities and their detection is therefore a challenging task. Mass spectrometry is a very sensitive technique and it will be demonstrated that it is a good choice for the study of plasma chemistry. Mass spectrometry measures the plasma composition directly at the surface and is not limited by existence of accessible optical transitions. When properly designed and carefully calibrated mass spectrometry provides absolute densities of the measured species. It can even measure internally excited metastable species. Here, measurement of neutral species and positive ions generated in an atmospheric pressure plasmas jet operated with He, hexamethyldisiloxane and O2 will be presented.

  18. Laser diagnostics on atmospheric pressure discharge plasmas, including cryoplasmas, in environments around room and cryogenic temperature

    Science.gov (United States)

    Sakakibara, Noritaka; Muneoka, Hitoshi; Urabe, Keiichiro; Yasui, Ryoma; Sakai, Osamu; Terashima, Kazuo

    2017-04-01

    Cryoplasmas, the plasma gas temperature (T g) of which can be controlled continuously below room temperature, show various unique and advantageous properties depending on T g. Recently, the T g dependence of plasma chemistry related to metastable helium (Hem) has been revealed in helium cryoplasmas. However, T g was only estimated by thermal calculation from the temperature outside the plasmas. In this study, for better evaluation of T g, near-infrared laser heterodyne interferometry (NIR-LHI) measurements were conducted in atmospheric pressure helium pulsed discharge plasmas at around room and cryogenic ambient temperatures (T a). The maximum difference between T g and T a was evaluated as 47 K at T a  =  300 K with 282 mW power consumption. To further investigate the T g dependence of plasma chemical reactions related to Hem, laser absorption spectroscopy (LAS) was performed on the same discharge plasmas to measure the Hem density and lifetime. The Hem lifetime was longer at lower T g, i.e. the lifetime at T g  =  145 K (9.6 µs) was seven times longer than that at T g  =  386 K (1.4 µs). By comparing the results with the numerically simulated rates of Hem quenching reactions taking T g into account, the mechanism of the Hem quenching reaction was revealed to vary with T g even though the main quenching reaction was a three-body collision at all T g. In this manner, the combination of NIR-LHI with LAS led directly to the T g dependence of Hem quenching reactions.

  19. Scattered light diagnostics of overdense plasma cavity in solid targets irradiated by an ultraintense laser pulse.

    Science.gov (United States)

    Andreev, A A; Zhidkov, A G; Uesaka, M; Kinoshita, K; Platonov, K Yu

    2002-09-01

    The light scattered backward from a target illuminated by ultraintense laser pulses carries important information about the nonlinear laser-plasma interaction. We analyze the usefulness of this information by plasma corona analysis with the help of an analytical model we developed, and particle-in-cell simulation. The spectrum of scattered light is shown to be shifted, to be broadened, and to be modulated, in comparison with the initial laser spectrum, and the spectral shift is an indicator of laser pulse contrast ratio.

  20. Terbium to Quantum Dot FRET Bioconjugates for Clinical Diagnostics: Influence of Human Plasma on Optical and Assembly Properties

    Directory of Open Access Journals (Sweden)

    Niko Hildebrandt

    2011-10-01

    Full Text Available Förster resonance energy transfer (FRET from luminescent terbium complexes (LTC as donors to semiconductor quantum dots (QDs as acceptors allows extraordinary large FRET efficiencies due to the long Förster distances afforded. Moreover, time-gated detection permits an efficient suppression of autofluorescent background leading to sub-picomolar detection limits even within multiplexed detection formats. These characteristics make FRET-systems with LTC and QDs excellent candidates for clinical diagnostics. So far, such proofs of principle for highly sensitive multiplexed biosensing have only been performed under optimized buffer conditions and interactions between real-life clinical media such as human serum or plasma and LTC-QD-FRET-systems have not yet been taken into account. Here we present an extensive spectroscopic analysis of absorption, excitation and emission spectra along with the luminescence decay times of both the single components as well as the assembled FRET-systems in TRIS-buffer, TRIS-buffer with 2% bovine serum albumin, and fresh human plasma. Moreover, we evaluated homogeneous LTC-QD FRET assays in QD conjugates assembled with either the well-known, specific biotin-streptavidin biological interaction or, alternatively, the metal-affinity coordination of histidine to zinc. In the case of conjugates assembled with biotin-streptavidin no significant interference with the optical and binding properties occurs whereas the histidine-zinc system appears to be affected by human plasma.

  1. The use of ultraviolet Thomson scattering as a versatile diagnostic for detailed measurements of a collisional laser produced plasma

    Energy Technology Data Exchange (ETDEWEB)

    Tracy, M.D.

    1993-01-08

    Collective Thomson scattering from ion-acoustic waves at 266nm is used to obtain spatially resolved, two-dimensional electron density, sound speed, and radial drift profiles of a collisional laser plasma. An ultraviolet diagnostic wavelength minimizes the complicating effects of inverse bremsstrahlung and refractive turning in the coronal region of interest, where the electron densities approach n{sub c}/10. Laser plasmas of this type are important because they model some of the aspects of the plasmas found in high-gain laser-fusion pellets irradiated by long pulse widths where the laser light is absorbed mostly in the corona. The experimental results and LASNEX simulations agree within a percent standard deviation of 40% for the electron density and 50% for the sound speed and radial drift velocity. Thus it is shown that the hydrodynamics equations with classical coefficients and the numerical approximations in LASNEX are valid models of laser-heated, highly collisional plasmas. The versatility of Thomson scattering is expanded upon by extending existing theory with a Fokker-Planck based model to include plasmas that are characterized by (0 {le} k{sub ia}{lambda}{sub ii} {le} {infinity}) and ZT{sub e}/T{sub i}, where k{sub ia} is the ion- acoustic wave number, {lambda}{sub ii} is the ion-ion mean free path, Z is the ionization state of the plasma, and T{sub e}, T{sub i} are the electron and ion temperatures in electron volts respectively. The model is valid for plasmas in which the electrons are approximately collisionless, (k{sub ia}{lambda}{sub ei}, k{sub ia}{lambda}{sub ee} {ge} 1), and quasineutrality holds, ({alpha} {much_gt}1), where {alpha} = 1/k{lambda}{sub DE} and {lambda}{sub DE} is the electron Debye length. This newly developed model predicts the lineshape of the ion-acoustic Thomson spectra and when fit to experimental data provides a direct measurement of the relative thermal flow velocity between the electrons and ions.

  2. Electron plasmas as a diagnostic tool for hyperfine spectroscopy of antihydrogen

    Science.gov (United States)

    Friesen, T.; Amole, C.; Ashkezari, M. D.; Baquero-Ruiz, M.; Bertsche, W.; Bowe, P. D.; Butler, E.; Capra, A.; Cesar, C. L.; Charlton, M.; Deller, A.; Evetts, N.; Eriksson, S.; Fajans, J.; Fujiwara, M. C.; Gill, D. R.; Gutierrez, A.; Hangst, J. S.; Hardy, W. N.; Hayden, M. E.; Isaac, C. A.; Jonsell, S.; Kurchaninov, L.; Little, A.; Madsen, N.; McKenna, J. T. K.; Menary, S.; Napoli, S. C.; Olchanski, K.; Olin, A.; Pusa, P.; Rasmussen, C. Ø.; Robicheaux, F.; Sarid, E.; Silveira, D. M.; So, C.; Stracka, S.; Thompson, R. I.; van der Werf, D. P.; Wurtele, J. S.

    2013-03-01

    Long term magnetic confinement of antihydrogen atoms has recently been demonstrated by the ALPHA collaboration at CERN, opening the door to a range of experimental possibilities. Of particular interest is a measurement of the antihydrogen spectrum. A precise comparison of the spectrum of antihydrogen with that of hydrogen would be an excellent test of CPT symmetry. One prime candidate for precision CPT tests is the ground-state hyperfine transition; measured in hydrogen to a precision of nearly one part in 1012. Effective execution of such an experiment with trapped antihydrogen requires precise knowledge of the magnetic environment. Here we present a solution that uses an electron plasma confined in the antihydrogen trapping region. The cyclotron resonance of the electron plasma is probed with microwaves at the cyclotron frequency and the subsequent heating of the electron plasma is measured through the plasma quadrupole mode frequency. Using this method, the minimum magnetic field of the neutral trap can be determined to within 4 parts in 104. This technique was used extensively in the recent demonstration of resonant interaction with the hyperfine levels of trapped antihydrogen atoms.

  3. L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources

    Science.gov (United States)

    Petkov, E. E.; Safronova, A. S.; Kantsyrev, V. L.; Shlyaptseva, V. V.; Rawat, R. S.; Tan, K. S.; Beiersdorfer, P.; Hell, N.; Brown, G. V.

    2016-11-01

    X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.

  4. ASTRO-H White Paper - Plasma Diagnostic and Dynamics of the Galactic Center Region

    CERN Document Server

    Koyama, K; Nobukawa, M; Uchiyama, H; Nakashima, S; Aharonian, F; Chernyakova, M; Ichinohe, Y; Nobukawa, K K; Maeda, Y; Matsumoto, H; Murakami, H; Ricci, C; Stawarz, L; Tanaka, T; Tsuru, T G; Watanabe, S; Yamauchi, S; Yuasa, T

    2014-01-01

    The most characteristic high-energy phenomena in the Galactic center (GC) region is the presence of strong K-shell emission lines from highly ionized Si, S, Ar, Ca, Fe and Ni, which form the Galactic Center X-ray Emission (GCXE). These multiple lines suggest that the GCXE is composed of at least two plasmas with temperatures of ~1 and ~7 keV. The GCXE also exhibits the K-shell lines from neutral Si, S, Ar, Ca, Fe and Ni atoms. A debatable issue is the origin of the GCXE plasma; whether it is a diffuse plasma or integrated emission of many unresolved point sources such as cataclysmic variables and active binaries. Detailed spectroscopy for these lines may provide a reliable picture of the GCXE plasma. The origin of the K-shell lines from neutral atoms is most likely the fluorescence by X-rays from a putative past flare of Sgr A*. Therefore ASTRO-H may provide unprecedented data for the past light curve of Sgr A*. All these lines may provide key information for the dynamics of the GCXE, using possible Doppler s...

  5. Electron plasmas as a diagnostic tool for hyperfine spectroscopy of antihydrogen

    Energy Technology Data Exchange (ETDEWEB)

    Friesen, T.; Thompson, R. I. [Department of Physics and Astronomy, University of Calgary, Calgary AB, T2N 1N4 (Canada); Amole, C.; Capra, A.; Menary, S. [Department of Physics and Astronomy, York University, Toronto ON, M3J 1P3 (Canada); Ashkezari, M. D.; Hayden, M. E. [Department of Physics, Simon Fraser University, Burnaby BC, V5A 1S6 (Canada); Baquero-Ruiz, M.; Fajans, J.; Little, A.; So, C.; Wurtele, J. S. [Department of Physics, University of California, Berkeley, CA 94720-7300 (United States); Bertsche, W. [School of Physics and Astronomy, University of Manchester, M13 9PL Manchester, UK and The Cockcroft Institute, WA4 4AD Warrington (United Kingdom); Bowe, P. D.; Hangst, J. S.; Rasmussen, C. O. [Department of Physics and Astronomy, Aarhus University, DK-8000 Aarhus C (Denmark); Butler, E. [Physics Department, CERN, CH-1211 Geneva 23 (Switzerland); Cesar, C. L.; Silveira, D. M. [Instituto de Fisica, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-972 (Brazil); Charlton, M. [Department of Physics, College of Science, Swansea University, Swansea SA2 8PP (United Kingdom); and others

    2013-03-19

    Long term magnetic confinement of antihydrogen atoms has recently been demonstrated by the ALPHA collaboration at CERN, opening the door to a range of experimental possibilities. Of particular interest is a measurement of the antihydrogen spectrum. A precise comparison of the spectrum of antihydrogen with that of hydrogen would be an excellent test of CPT symmetry. One prime candidate for precision CPT tests is the ground-state hyperfine transition; measured in hydrogen to a precision of nearly one part in 10{sup 12}. Effective execution of such an experiment with trapped antihydrogen requires precise knowledge of the magnetic environment. Here we present a solution that uses an electron plasma confined in the antihydrogen trapping region. The cyclotron resonance of the electron plasma is probed with microwaves at the cyclotron frequency and the subsequent heating of the electron plasma is measured through the plasma quadrupole mode frequency. Using this method, the minimum magnetic field of the neutral trap can be determined to within 4 parts in 10{sup 4}. This technique was used extensively in the recent demonstration of resonant interaction with the hyperfine levels of trapped antihydrogen atoms.

  6. L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Petkov, E. E., E-mail: emilp@unr.edu; Safronova, A. S.; Kantsyrev, V. L.; Shlyaptseva, V. V. [University of Nevada, Reno, Nevada 89557 (United States); Rawat, R. S.; Tan, K. S. [National Institute of Education, Nanyang Technological University, Singapore 637616 (Singapore); Beiersdorfer, P.; Brown, G. V. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Hell, N. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Dr. Remeis-Sternwarte and ECAP, Universität Erlangen-Nürnberg, 96049 Bamberg (Germany)

    2016-11-15

    X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.

  7. X-ray Diagnostics of Thermal Conditions of the Hot Plasmas in the Centaurus Cluster

    CERN Document Server

    Takahashi, I; Makishima, K; Matsushita, K; Fukazawa, Y; Ikebe, Y; Kitaguchi, T; Kokubun, M; Nakazawa, K; Okuyama, S; Ota, N; Tamura, T

    2009-01-01

    X-ray data of the Centaurus cluster, obtained with {\\it XMM-Newton} for 45 ksec, were analyzed. Deprojected EPIC spectra from concentric thin shell regions were reproduced equally well by a single-phase plasma emission model, or by a two-phase model developed by {\\it ASCA}, both incorporating cool (1.7--2.0 keV) and hot ($\\sim 4$ keV) plasma temperatures. However, EPIC spectra with higher statistics, accumulated over 3-dimentional thick shell regions, were reproduced better by the two-phase model than by the singe-phase one. Therefore, hot and cool plasma phases are inferred to co-exist in the cluster core region within $\\sim 70$ kpc. The iron and silicon abundances of the plasma were reconfirmed to increase significantly towards the center, while that of oxygen was consistent with being radially constant. The implied non-solar abundance ratios explains away the previously reported excess X-ray absorption from the central region. Although an additional cool ($\\sim 0.7$ keV) emission was detected within $\\sim ...

  8. Laser diagnostics and modeling of plasma assisted CVD. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Plasma assisted chemical vapor deposition (PACVD) represents a novel approach for utilizing the nonequilibrium effects of reactive plasmas for depositing a wide range of protective hardface coatings that have both wear and erosion application. The nonequilibrium plasma is the heart of this complex system and has the function of generating the reactive molecular fragments (radicals) and atomic species at concentration levels unattainable by other competing processes. It is now widely accepted that such advanced protective hardface coatings materials will play a vital role in the energy technologies of the coming decades, with major applications in diverse areas ranging from aerospace and commercial propulsion systems (jet engines) to automotive components and internal combustion engines, (ceramic heat engines), cutting and machining tools, electronic packaging, thermal management, and possibly room-temperature superconductors. Wear and associated erosion aspects are responsible for an enormous expenditure of energy and fiscal resources in almost all DOE applications. Many of the results from this investigation arc also applicable to other materials processing reactors such as electron beam, PVD, CVD, laser ablation, microwave, high energy cathodic arc, thermal plasma (rf or dc) and combustion spray. These also include the various hybrid systems such as the rf/dc arc as used in Japan for diamond deposition and e-beam PVD deposition of advanced titanium alloy coatings as used at the Paton Institute in Kiev, Ukraine.

  9. High-energy resolution Thomson Parabola spectrometer for laser plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G. A. P.; Schillaci, F. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Institute of Physics of the ASCR, ELI-Beamlines project, Na Slovance 2, Prague (Czech Republic); Carpinelli, M. [INFN Sezione di Cagliari, c/o Dipartimento di Fisica, Università di Cagliari, Cagliari (Italy); Cuttone, G.; Romano, F. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania (Italy); Maggiore, M. [Institute of Physics of the ASCR, ELI-Beamlines project, Na Slovance 2, Prague, Czech Republic and Laboratori Nazionali di Legnaro, INFN, Via Università 2, Legnaro (PD) (Italy); Ter-Avetisyan, S. [Laboratori Nazionali di Legnaro, INFN, Via Università 2, Legnaro (PD) (Italy); Tramontana, A. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and School of Mathematics and Physics, The Queen' s University Belfast, BT7 1NN (United Kingdom); Velyhan, A. [Institute of Physics of the ASCR, ELI-Beamlines project, Na Slovance 2, Prague (Czech Republic)

    2013-07-26

    Thomson Parabola (TP) spectrometers are widely used devices for laser-driven beam diagnostics as they provide a complete set of information on the accelerated particles. A novel TP has been developed at LNS with a design able to detect protons up to 20 MeV. The layout design and some results obtained during the experimental campaign at PALS laboratory will be reported in the following.

  10. DIRECT SMEAR VS CELL BLOCK (PLASMA- THROMBIN CLOT) METHOD: DIAGNOSTIC VALUE IN SEROSAL CAVITIES FLUIDS CYTOLOGY

    OpenAIRE

    Mahzouni, P.; M SHARIFANI

    2000-01-01

    Introduction. To improve testing sensitivity, most laboratories use two or more preparation methods but in our laboratories only one method is used which is "direct smear". In this study we tried to evaluate the diagnostic value of cell block as adjunct to direct smear in the cytologic investigation of serosal cavities fluids. Methods. In a clinical trial study 62 specimens of serosal cavity fluids were investigated in AL-Zahrapathology laboratory (Get. 1998 to Get. 1999). Cytologic slid...

  11. Mass spectrometric signatures of the blood plasma metabolome for disease diagnostics.

    Science.gov (United States)

    Lokhov, Petr G; Balashova, Elena E; Voskresenskaya, Anna A; Trifonova, Oxana P; Maslov, Dmitry L; Archakov, Alexander I

    2016-01-01

    In metabolomics, a large number of small molecules can be detected in a single run. However, metabolomic data do not include the absolute concentrations of each metabolite. Generally, mass spectrometry analyses provide metabolite concentrations that are derived from mass peak intensities, and the peak intensities are strictly dependent on the type of mass spectrometer used, as well as the technical characteristics, options and protocols applied. To convert mass peak intensities to actual concentrations, calibration curves have to be generated for each metabolite, and this represents a significant challenge depending on the number of metabolites that are detected and involved in metabolome-based diagnostics. To overcome this limitation, and to facilitate the development of diagnostic tests based on metabolomics, mass peak intensities may be expressed in quintiles. The present study demonstrates the advantage of this approach. The examples of diagnostic signatures, which were designed in accordance to this approach, are provided for lung and prostate cancer (leading causes of mortality due to cancer in developed countries) and impaired glucose tolerance (which precedes type 2 diabetes, the most common endocrinology disease worldwide).

  12. Numerical simulations used for a validity check on the laser induced photo-detachment diagnostic method in electronegative plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Oudini, N. [Laboratoire des plasmas de décharges, Centre de Développement des Technologies Avancées, Cité du 20 Aout BP 17 Baba Hassen, 16081 Algiers (Algeria); Taccogna, F. [Istituto di Metodologie Inorganiche e dei Plasmi, CNR, via Amendola 122/D, 70126 Bari (Italy); Bendib, A. [Laboratoire d' Electronique Quantique, Faculté de Physique, USTHB, El Alia BP 32, Bab Ezzouar 16111, Algiers (Algeria); Aanesland, A. [Laboratoire de Physique des Plasmas (CNRS, Ecole Polytechnique, Sorbonne Universités, UPMC Univ Paris 06, Univ Paris-Sud), École Polytechnique, 91128 Palaiseau Cedex (France)

    2014-06-15

    Laser photo-detachment is used as a method to measure or determine the negative ion density and temperature in electronegative plasmas. In essence, the method consists of producing an electropositive channel (negative ion free region) via pulsed laser photo-detachment within an electronegative plasma bulk. Electrostatic probes placed in this channel measure the change in the electron density. A second pulse might be used to track the negative ion recovery. From this, the negative ion density and temperature can be determined. We study the formation and relaxation of the electropositive channel via a two-dimensional Particle-In-Cell/Mote Carlo collision model. The simulation is mainly carried out in a Hydrogen plasma with an electronegativity of α = 1, with a parametric study for α up to 20. The temporal and spatial evolution of the plasma potential and the electron densities shows the formation of a double layer (DL) confining the photo-detached electrons within the electropositive channel. This DL evolves into two fronts that move in the opposite directions inside and outside of the laser spot region. As a consequence, within the laser spot region, the background and photo-detached electron energy distribution function relaxes/thermalizes via collisionless effects such as Fermi acceleration and Landau damping. Moreover, the simulations show that collisional effects and the DL electric field strength might play a non-negligible role in the negative ion recovery within the laser spot region, leading to a two-temperature negative ion distribution. The latter result might have important effects in the determination of the negative ion density and temperature from laser photo detachment diagnostic.

  13. Use of soft x-ray diagnostic on the COMPASS tokamak for investigations of sawteeth crash neighborhood and of plasma position using fast inversion methods

    Energy Technology Data Exchange (ETDEWEB)

    Imrisek, M. [Institute of Plasma Physics ASCR, Prague (Czech Republic); Faculty of Mathematics and Physics, Charles University in Prague, Prague (Czech Republic); Weinzettl, V.; Mlynar, J.; Panek, R.; Hron, M. [Institute of Plasma Physics ASCR, Prague (Czech Republic); Odstrcil, T. [Max-Planck-Institut für Plasmaphysik, Garching (Germany); Odstrcil, M. [Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Prague (Czech Republic); Optical Research Center, University of Southampton, Southampton (United Kingdom); Ficker, O. [Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Prague (Czech Republic); Pinzon, J. R. [Institue Jean Lamour, Université de Lorraine, Nancy (France); Ehrlacher, C. [ENS Cachan, Paris (France)

    2014-11-15

    The soft x-ray diagnostic is suitable for monitoring plasma activity in the tokamak core, e.g., sawtooth instability. Moreover, spatially resolved measurements can provide information about plasma position and shape, which can supplement magnetic measurements. In this contribution, fast algorithms with the potential for a real-time use are tested on the data from the COMPASS tokamak. In addition, the soft x-ray data are compared with data from other diagnostics in order to discuss possible connection between sawtooth instability on one side and the transition to higher confinement mode, edge localized modes and productions of runaway electrons on the other side.

  14. SiC detectors for radiation sources characterization and fast plasma diagnostic

    Science.gov (United States)

    Cannavò, A.; Torrisi, L.

    2016-09-01

    Semiconductor detectors based on SiC have been investigated to characterize the radiations (photons and particles) emitted from different sources, such as radioactive sources, electron guns, X-ray tubes and laser-generated plasmas. Detectors show high response velocity, low leakage current, high energy gap and high radiation hardness. Their high detection efficiency permits to use the detectors in spectroscopic mode and in time-of-flight (TOF) approach, generally employed to monitor low and high radiation fluxes, respectively. Using the laser start signal, they permit to study the properties of the generated plasma in vacuum by measuring accurately the particle velocity and energy using pulsed lasers at low and high intensities. Possible applications will be reported and discussed.

  15. GEM detector development for tokamak plasma radiation diagnostics: SXR poloidal tomography

    Science.gov (United States)

    Chernyshova, Maryna; Malinowski, Karol; Ziółkowski, Adam; Kowalska-Strzeciwilk, Ewa; Czarski, Tomasz; Poźniak, Krzysztof T.; Kasprowicz, Grzegorz; Zabołotny, Wojciech; Wojeński, Andrzej; Kolasiński, Piotr; Krawczyk, Rafał D.

    2015-09-01

    An increased attention to tungsten material is related to a fact that it became a main candidate for the plasma facing material in ITER and future fusion reactor. The proposed work refers to the studies of W influence on the plasma performances by developing new detectors based on Gas Electron Multiplier GEM) technology for tomographic studies of tungsten transport in ITER-oriented tokamaks, e.g. WEST project. It presents current stage of design and developing of cylindrically bent SXR GEM detector construction for horizontal port implementation. Concept to overcome an influence of constraints on vertical port has been also presented. It is expected that the detecting unit under development, when implemented, will add to the safe operation of tokamak bringing creation of sustainable nuclear fusion reactors a step closer.

  16. Plasma breakdown diagnostics with the biased disc of electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O; Ropponen, T; Toivanen, V; Arje, J; Koivisto, H [University of Jyvaeskylae, Department of Physics, Accelerator Laboratory, PO Box 35 (YFL), 40500 Jyvaeskylae (Finland)], E-mail: olli.tarvainen@jyu.fi

    2009-08-15

    The electron cyclotron resonance ion sources at the JYFL (University of Jyvaeskylae, Department of Physics) accelerator laboratory have been operated in pulsed mode to study the time-resolved current signal from the biased discs of the ion sources. The purpose of the experiments is to gain an understanding of the ion source parameters affecting the time required for the transition from neutral gas to plasma. It was observed that the plasma breakdown time depends strongly on the neutral gas density, gas species and density of seed electrons. In particular, it was observed that a low power microwave signal at secondary frequency makes the breakdown time virtually independent of the neutral gas density. The results can be utilized for operation of ECR ion sources in the so-called preglow mode. A simple qualitative model, which is in good agreement with the experiments, has been developed to interpret the results.

  17. Identification of hepatotropic viruses from plasma using deep sequencing: a next generation diagnostic tool.

    Directory of Open Access Journals (Sweden)

    John Law

    Full Text Available We conducted an unbiased metagenomics survey using plasma from patients with chronic hepatitis B, chronic hepatitis C, autoimmune hepatitis (AIH, non-alcoholic steatohepatitis (NASH, and patients without liver disease (control. RNA and DNA libraries were sequenced from plasma filtrates enriched in viral particles to catalog virus populations. Hepatitis viruses were readily detected at high coverage in patients with chronic viral hepatitis B and C, but only a limited number of sequences resembling other viruses were found. The exception was a library from a patient diagnosed with hepatitis C virus (HCV infection that contained multiple sequences matching GB virus C (GBV-C. Abundant GBV-C reads were also found in plasma from patients with AIH, whereas Torque teno virus (TTV was found at high frequency in samples from patients with AIH and NASH. After taxonomic classification of sequences by BLASTn, a substantial fraction in each library, ranging from 35% to 76%, remained unclassified. These unknown sequences were assembled into scaffolds along with virus, phage and endogenous retrovirus sequences and then analyzed by BLASTx against the non-redundant protein database. Nearly the full genome of a heretofore-unknown circovirus was assembled and many scaffolds that encoded proteins with similarity to plant, insect and mammalian viruses. The presence of this novel circovirus was confirmed by PCR. BLASTx also identified many polypeptides resembling nucleo-cytoplasmic large DNA viruses (NCLDV proteins. We re-evaluated these alignments with a profile hidden Markov method, HHblits, and observed inconsistencies in the target proteins reported by the different algorithms. This suggests that sequence alignments are insufficient to identify NCLDV proteins, especially when these alignments are only to small portions of the target protein. Nevertheless, we have now established a reliable protocol for the identification of viruses in plasma that can also be

  18. Langmuir probe diagnostics of an atmospheric pressure, vortex-stabilized nitrogen plasma jet

    Energy Technology Data Exchange (ETDEWEB)

    Prevosto, L.; Mancinelli, B. R. [Grupo de Descargas Electricas, Departamento Ingenieria Electromecanica, Facultad Regional Venado Tuerto (UTN), Laprida 651, (2600) Venado Tuerto, Santa Fe (Argentina); Kelly, H. [Grupo de Descargas Electricas, Departamento Ingenieria Electromecanica, Facultad Regional Venado Tuerto (UTN), Laprida 651, (2600) Venado Tuerto, Santa Fe (Argentina) and Instituto de Fisica del Plasma (CONICET), Departamento de Fisica, Facultad de Ciencias Exactas y Naturales UBA Ciudad Universitaria Pab. I, (1428) Buenos Aires (Argentina)

    2012-09-15

    Langmuir probe measurements in an atmospheric pressure direct current (dc) plasma jet are reported. Sweeping probes were used. The experiment was carried out using a dc non-transferred arc torch with a rod-type cathode and an anode of 5 mm diameter. The torch was operated at a nominal power level of 15 kW with a nitrogen flow rate of 25 Nl min{sup -1}. A flat ion saturation region was found in the current-voltage curve of the probe. The ion saturation current to a cylindrical probe in a high-pressure non local thermal equilibrium (LTE) plasma was modeled. Thermal effects and ionization/recombination processes inside the probe perturbed region were taken into account. Averaged radial profiles of the electron and heavy particle temperatures as well as the electron density were obtained. An electron temperature around 11 000 K, a heavy particle temperature around 9500 K and an electron density of about 4 Multiplication-Sign 10{sup 22} m{sup -3}, were found at the jet centre at 3.5 mm downstream from the torch exit. Large deviations from kinetic equilibrium were found throughout the plasma jet. The electron and heavy particle temperature profiles showed good agreement with those reported in the literature by using spectroscopic techniques. It was also found that the temperature radial profile based on LTE was very close to that of the electrons. The calculations have shown that this method is particularly useful for studying spraying-type plasma jets characterized by electron temperatures in the range 9000-14 000 K.

  19. High resolution X-ray spherically bent crystal spectrometer for laser-produced plasma diagnostics

    Institute of Scientific and Technical Information of China (English)

    Shali Xiao; Hongjian Wang; Jun Shi; Changhuan Tang; Shenye Liu

    2009-01-01

    A new high spectral resolution crystal spectrometer is designed to measure very low emissive X-ray spectra of laser-produced plasma in 0.5 - 0.9 nm range. A large open aperture (30 x 20 (mm)) mica (002) spherically bent crystal with curvature radius R = 380 mm is used as dispersive and focusing element. The imaging plate is employed to obtain high spectral resolution with effective area of 30 x 80 (mm). The long designed path of the X-ray spectrometer beam is 980 mm from the source to the detector via the crystal. Experiment is carried out at a 20-J laser facility. X-ray spectra in an absolute intensity scale is obtained from Al laser produced plasmas created by laser energy of 6.78 J. Samples of spectra obtained with spectral resolution of up to E/鈻矱 ~ 1500 are presented. The results clearly show that the device is good to diagnose laser high-density plasmas.

  20. LIF diagnostics of hydroxyl radical in a methanol containing atmospheric-pressure plasma jet

    Science.gov (United States)

    Qian, Mu-Yang; Liu, San-Qiu; Pei, Xue-Kai; Lu, Xin-Pei; Zhang, Jia-Liang; Wang, De-Zhen

    2016-10-01

    In this paper, a pulsed-dc CH3OH/Ar plasma jet generated at atmospheric pressure is studied by laser-induced fluorescence (LIF) and optical emission spectroscopy (OES). A gas-liquid bubbler system is proposed to introduce the methanol vapor into the argon gas, and the CH3OH/Ar volume ratio is kept constant at about 0.1%. Discharge occurs in a 6-mm needle-to-ring gap in an atmospheric-pressure CH3OH/Ar mixture. The space-resolved distributions of OH LIF inside and outside the nozzle exhibit distinctly different behaviors. And, different production mechanisms of OH radicals in the needle-to-ring discharge gap and afterglow of plasma jet are discussed. Besides, the optical emission lines of carbonaceous species, such as CH, CN, and C2 radicals, are identified in the CH3OH/Ar plasma jet. Finally, the influences of operating parameters (applied voltage magnitude, pulse frequency, pulsewidth) on the OH radical density are also presented and analyzed. Project supported by the National Natural Science Foundation of China (Grant Nos. 11465013 and 11375041), the Natural Science Foundation of Jiangxi Province, China (Grant Nos. 20151BAB212012 and 20161BAB201013), and the International Science and Technology Cooperation Program of China (Grant No. 2015DFA61800).

  1. Diagnostics of plasma decay and afterglow transient of an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O; Ropponen, T; Toivanen, V; Kalvas, T; Arje, J; Koivisto, H, E-mail: olli.tarvainen@jyu.f [University of Jyvaeskylae, Department of Physics, Accelerator Laboratory PO Box 35 (YFL), 40500 Jyvaeskylae (Finland)

    2010-08-15

    The electron cyclotron resonance ion sources at the JYFL (University of Jyvaeskylae, Department of Physics) accelerator laboratory have been operated in pulsed mode to study the decay of bremsstrahlung emission and ion beam currents of different charge states. The purpose of the experiments is to gain understanding on the ion source parameters affecting the afterglow. It was observed that the bremsstrahlung emission characteristics during the afterglow and decay times of extracted ion beam currents are virtually independent of the ion source tuning parameters. The decay time of different charge states was found to be almost inversely proportional to the square of the ion charge. The result is in good agreement with a simple theoretical model based on diffusion of ions from the magnetic field of the ion source. It was observed that the plasma decay time is shorter in the case of the ion source with lower operation frequency and, thus, lower magnetic field strength. The scaling between the ion sources supports a model based on Bohm diffusion, arising from non-linear effects such as instabilities and fluctuating fields in turbulent plasma. The experiments provide information on the mechanisms causing instabilities during the plasma decay.

  2. Study of the Plasma Turbulence Dynamics by Measurements of Diagnostic Stimulated Electromagnetic Emission. Part II. Results of Numerical Simulation

    Science.gov (United States)

    Sergeev, E. N.; Grach, S. M.

    2017-07-01

    The data on measured dynamic characteristics of diagnostic stimulated electromagnetic emission (SEE) of the ionosphere are presented. Numerical simulations of the SEE evolution within the framework of a theoretical model of the broad-continuum SEE feature with the use of improved (3D) empirical model of the spatial spectrum of artificial irregularities of the HF pumped ionospheric plasma are performed and compared with the measurement data. Possible applications of such a comparison for determining the spectrum parameters and studying the evolution of the geomagnetic field-aligned artificial irregularities (striations) are discussed. It is concluded that changes in the intensity and spectrum shape of the striations, mainly for transverse scales l ⊥ 2-18 m, play the decisive role in the observed variations of the magnitude and temporal characteristics of the overshoot effect (formation of the intensity maximum followed by the suppression of the ionospheric SEE intensity).

  3. A novel ultra-thin 3D detector—For plasma diagnostics at JET and ITER tokamaks

    Science.gov (United States)

    García, Francisco; Pelligrini, G.; Balbuena, J.; Lozano, M.; Orava, R.; Ullan, M.

    2009-08-01

    A novel ultra-thin silicon detector called U3DTHIN has been designed and built for applications that range from Neutral Particle Analyzers (NPA) used in Corpuscular Diagnostics of High Temperature Plasma to very low X-ray spectroscopy. The main purpose of this detector is to provide a state-of-the-art solution to upgrade the current detector system of the NPAs at JET and also to pave the road for the future detection systems of the ITER experimental reactor. Currently the NPAs use a very thin scintillator-photomultiplier tube [F. García, S.S. Kozlovsky, D.V. Balin, Background Properties of CEM, MCP and PMT detectors at n-γ irradiation. Preprint PNPI-2392, Gatchina, 2000, p. 9 [1]; F. García, S.S. Kozlovsky, V.V. Ianovsky, Scintillation Detectors with Low Sensitivity to n-γ Background. Preprint PNPI-2391, Gatchina, 2000, p. 8 [2

  4. A real-time algorithm for the harmonic estimation and frequency tracking of dominant components in fusion plasma magnetic diagnostics

    Science.gov (United States)

    Alves, D.; Coelho, R.; JET-EFDA Contributors

    2013-08-01

    The real-time tracking of instantaneous quantities such as frequency, amplitude, and phase of components immerse in noisy signals has been a common problem in many scientific and engineering fields such as power systems and delivery, telecommunications, and acoustics for the past decades. In magnetically confined fusion research, extracting this sort of information from magnetic signals can be of valuable assistance in, for instance, feedback control of detrimental magnetohydrodynamic modes and disruption avoidance mechanisms by monitoring instability growth or anticipating mode-locking events. This work is focused on nonlinear Kalman filter based methods for tackling this problem. Similar methods have already proven their merits and have been successfully employed in this scientific domain in applications such as amplitude demodulation for the motional Stark effect diagnostic. In the course of this work, three approaches are described, compared, and discussed using magnetic signals from the Joint European Torus tokamak plasma discharges for benchmarking purposes.

  5. Diagnostics of hemangioma by the methods of correlation and fractal analysis of laser microscopic images of blood plasma

    Science.gov (United States)

    Boychuk, T. M.; Bodnar, B. M.; Vatamanesku, L. I.

    2012-01-01

    For the first time the complex correlation and fractal analysis was used for the investigation of microscopic images of both tissue images and hemangioma liquids. It was proposed a physical model of description of phase distributions formation of coherent radiation, which was transformed by optical anisotropic biological structures. The phase maps of laser radiation in the boundary diffraction zone were used as the main information parameter. The results of investigating the interrelation between the values of correlation (correlation area, asymmetry coefficient and autocorrelation function excess) and fractal (dispersion of logarithmic dependencies of power spectra) parameters are presented. They characterize the coordinate distributions of phase shifts in the points of laser images of histological sections of hemangioma, hemangioma blood smears and blood plasma with vascular system pathologies. The diagnostic criteria of hemangioma nascency are determined.

  6. Plasma diagnostics in TFTR using emission of cyclotron radiation at arbitrary frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Fidone, I.; Giruzzi, G.; Taylor, G.

    1995-07-01

    Emission of cyclotron radiation at arbitrary wave frequency for diagnostic purposes is discussed. It is shown that the radiation spectrum at arbitrary frequencies is more informative than the first few harmonics and it is suited for diagnosis of superthermal electrons without any {open_quotes}ad hoc{close_quotes} value of the wall reflection coefficient. Thermal radiation from TFTR is investigated and it is shown that the bulk and the tail of the electron momentum distribution during strong neutral beam injection is a Maxwellian with a single temperature in all ranges of electron energies.

  7. A high repetition rate transverse beam profile diagnostic for laser-plasma proton sources

    Science.gov (United States)

    Dover, Nicholas; Nishiuchi, Mamiko; Sakaki, Hironao; Kando, Masaki; Nishitani, Keita

    2016-10-01

    The recently upgraded J-KAREN-P laser can provide PW peak power and intensities approaching 1022 Wcm-2 at 0.1 Hz. Scaling of sheath acceleration to such high intensities predicts generation of protons to near 100 MeV, but changes in electron heating mechanisms may affect the emitted proton beam properties, such as divergence and pointing. High repetition rate simultaneous measurement of the transverse proton distribution and energy spectrum are therefore key to understanding and optimising the source. Recently plastic scintillators have been used to measure online proton beam transverse profiles, removing the need for time consuming post-processing. We are therefore developing a scintillator based transverse proton beam profile diagnostic for use in ion acceleration experiments using the J-KAREN-P laser. Differential filtering provides a coarse energy spectrum measurement, and time-gating allows differentiation of protons from other radiation. We will discuss the design and implementation of the diagnostic, as well as proof-of-principle results from initial experiments on the J-KAREN-P system demonstrating the measurement of sheath accelerated proton beams up to 20 MeV.

  8. X-ray optical diagnostic of laser produced plasmas for nuclear fusion and X-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Butzbach, R.

    2001-07-01

    In the present work, the conception, design and appliance of toroidally bent crystals for the X-ray optical diagnostics of laser produced plasmas is discussed. The first part of this work deals with the development, design and characterization of an X-Ray microscope for the observation of Rayleigh-Taylor instabilities, which act against the confinement and ignition of the fuel in the inertial confinement fusion process. The aim of the second part of the present work was the diagnostic of the lasing medium for amplified spontaneous emission close to the water window. For this purpose, an one-dimensionally (1-D) imaging X-ray spectrometer based on toroidally bent quartz crystals was developed for the observation of the Ni-like 4f-3d transition of Yb, Hf, Ta, and W ions, which should be related to the amplified 4d-4p emission, since the 4f niveau is very close to the 4d niveau. Thus, the 4f-3d transition can serve as an indicator for the population of the 4d niveau. (orig.)

  9. Optical fiber imaging for high speed plasma motion diagnostics: applied to low voltage circuit breakers.

    Science.gov (United States)

    McBride, J W; Balestrero, A; Ghezzi, L; Tribulato, G; Cross, K J

    2010-05-01

    An integrated portable measurement system is described for the study of high speed and high temperature unsteady plasma flows such as those found in the vicinity of high current switching arcs. An array of optical fibers allows the formation of low spatial resolution images, with a maximum capture rate of 1 x 10(6) images per second (1 MHz), with 8 bit intensity resolution. Novel software techniques are reported to allow imaging of the arc; and to measure arc trajectories. Results are presented on high current (2 kA) discharge events in a model test fixture and on the application to a commercial low voltage circuit breaker.

  10. High-resolution spectroscopic diagnostics of very high-temperature plasmas in the hard x-ray regime

    Energy Technology Data Exchange (ETDEWEB)

    Widmann, K

    1999-12-06

    Motivated by the need for establishing a reliable database useful for the application of x-ray spectroscopic tools for the diagnostic of very high temperature plasmas, high-resolution crystal spectrometer measurements have been performed investigating the characteristic K-shell radiation of highly charged krypton and xenon. The measurements, which have been performed at the Electron-Beam-Ion-Trap (EBIT) facility of the Lawrence Livermore National Laboratory, include the investigation of the n = 2 {yields} 1 transitions in heliumlike krypton (Kr{sup 34+}) and innershell excited lithiumlike krypton (Kr{sup 33+}) utilizing a conventional reflection-type crystal spectrometer of von Hamos geometry. The electron-excitation-energy selective measurements map the contribution of the dielectronic recombination lines providing the means of accurate interpretation of the line profiles of the characteristic K{alpha} x-ray emission of plasmas. The high-resolution measurements of the n = 2 {yields} 1 transitions in heliumlike xenon (Xe{sup 52+}) and hydrogenlike xenon (Xe{sup 53+}) were based on a new transmission-type crystal spectrometer of DuMond geometry. The resolving power of the developed spectrometer was sufficient for charge state specific observation allowing the determination of the electron-impact excitation cross section for the hydrogen- and heliumlike K{alpha} transitions. The disagreement with theoretically predicted values is a measure of the magnitude of the Breit interaction for the highly charged high-Z ions.

  11. A Diagnostic Dilemma: Waldenström's Macroglobulinemia/Plasma Cell Leukemia

    Directory of Open Access Journals (Sweden)

    Bhawna Sethi

    2012-01-01

    Full Text Available Waldenström's macroglobulinemia is a B-cell neoplasm characterized by infiltration of the bone marrow by a lymphoplasmacytic infiltrate and an IgM monoclonal gammopathy. It is an uncommon disease with overall incidence of approximately 3 per million persons per year, accounting for approximately 1% to 2% of all hematologic cancers. It has only one-sixth the estimated prevalence of plasma cell myeloma. Disease symptoms can be due to infiltration of bone marrow and other tissue sites by malignant lymphoplasmacytic cells or due to the effects of elevated serum IgM levels. However, patients may present with constitutional symptoms only or may be asymptomatic. In our case, patient presented with chief complaints of fatigability and dyspnoea and was misdiagnosed as plasma cell leukemia on peripheral blood film and bone marrow morphology, but turned out to be a case of Waldenström's macroglobulinemia on cytoflorometry. The patient was referred for chemotherapy but expired on 10th day of admission. The suspected cause of death was cardiorespiratory failure.

  12. Synthetic aperture microwave imaging with active probing for fusion plasma diagnostics

    CERN Document Server

    Shevchenko, Vladimir F; Freethy, Simon J; Huang, Billy K

    2012-01-01

    A Synthetic Aperture Microwave Imaging (SAMI) system has been designed and built to obtain 2-D images at several frequencies from fusion plasmas. SAMI uses a phased array of linearly polarised antennas. The array configuration has been optimised to achieve maximum synthetic aperture beam efficiency. The signals received by antennas are down-converted to the intermediate frequency range and then recorded in a full vector form. Full vector signals allow beam focusing and image reconstruction in both real time and a post processing mode. SAMI can scan over 16 preprogrammed frequencies in the range of 10-35GHz with a switching time of 300ns. The system operates in 2 different modes simultaneously: both a passive imaging of plasma emission and also an active imaging of the back-scattered signal of the radiation launched by one of the antennas from the same array. This second mode is similar to so-called Doppler backscattering (DBS) reflectometry with 2-D resolution of the propagation velocity of turbulent structur...

  13. UV and x-ray spectral lines of FeXXIII ion for plasma diagnostics

    CERN Document Server

    Murakami, I; Murakami, Izumi; Kato, Takako

    1996-01-01

    We have calculated X-ray and UV spectra of Be-like Fe (FeXXIII) ion in collisional-radiative model including all fine-structure transitions among the 2s^2, 2s2p, 2p^2, 2snl, and 2pnl levels where n=3 and 4, adopting data for the collision strengths by Zhang & Sampson (1992) and by Sampson, Goett, & Clark (1984). Some line intensity ratios can be used for the temperature diagnostics. We show 5 ratios in UV region and 9 ratios in X-ray region as a function of electron temperature and density at 0.3keV < T_e < 10keV and n_e = 1 - 10^{25} cm^{-3}. The effect of cascade in these line ratios and in the level population densities are discussed.

  14. MIT modular x-ray source systems for the study of plasma diagnostics

    Science.gov (United States)

    Coleman, J. W.; Wenzel, K. W.; Petrasso, R. D.; Lo, D. H.; Li, C. K.; Lierzer, J. R.; Wei, T.

    1992-10-01

    Two new x-ray source systems are now on line at our facility. Each provides an e-beam to 25 kV. Targets are interchangeable between machines, and four x-ray detectors may be used simultaneously with a target. The gridded e-gun of the RACEHORSE system gives a 0.5-1.0-cm pulsable spot on target. The nongridded e-gun of the SCORPION system provides a 0.3-mm or smaller dc microspot on target. RACEHORSE is being used to study and characterize type-II diamond photoconductors for use in diagnosing plasmas, while SCORPION is being used to develop a slitless spectrograph using photographic film. Source design details and some RACEHORSE results are presented.

  15. Plasma diagnostics and modeling of direct current microplasma discharges at atmospheric pressure

    Science.gov (United States)

    Wang, Qiang

    High pressure (100s of torr) microplasma (length scale 100s of micrometer) non-equilibrium discharges have potential applications as chemical microreactors, sensors, microelectromechanical systems (MEMS), and excimer radiation sources. Experimental and theoretical studies of these microplasmas can provide critical information on fundamental discharge characteristics, and help extend the window of stable discharge operation. Spatially resolved measurements (resolution ˜ 6 mum) were taken across a 200 mum slot-type microdischarge in atmospheric pressure helium or argon. Small amounts of actinometer gases were added to the flow for optical emission spectroscopy measurements. Gas temperature profiles were determined from N2 emission rotational spectroscopy. Stark splitting of the hydrogen Balmer-beta (Hbeta ) line was used to investigate the electric field distribution in the cathode sheath region. Electron densities were evaluated from the analysis of the spectral line broadenings of Hbeta emission. The measured gas temperature was in the range of 350--650 K in He, and 600--1200 K in Ar, both peaking near the cathode and increasing with power. The electron density in the bulk plasma was in the range (3-7)x1013 cm -3 in He, and (1-4)x1014 cm-3 in Ar. The measured electric field in He peaked at the cathode and decayed to small values over a distance of ˜50 mum (sheath edge) from the cathode. The experimental data were also used to validate a self-consistent one-dimensional plasma model. By a combination of measurements and simulation it was found that the dominant gas heating mechanism in DC microplasmas was ion Joule heating. Simulation results also predicted the existence of electric field reversals in the negative glow under operating conditions that favor a high electron diffusion flux emanating from the cathode sheath. The electric field adjusted to satisfy continuity of the total current. Also, the electric field in the anode layer was self adjusted to be

  16. Compact, accurate description of diagnostic neutral beam propagation and attenuation in a high temperature plasma for charge exchange recombination spectroscopy analysis.

    Science.gov (United States)

    Bespamyatnov, Igor O; Rowan, William L; Granetz, Robert S

    2008-10-01

    Charge exchange recombination spectroscopy on Alcator C-Mod relies on the use of the diagnostic neutral beam injector as a source of neutral particles which penetrate deep into the plasma. It employs the emission resulting from the interaction of the beam atoms with fully ionized impurity ions. To interpret the emission from a given point in the plasma as the density of emitting impurity ions, the density of beam atoms must be known. Here, an analysis of beam propagation is described which yields the beam density profile throughout the beam trajectory from the neutral beam injector to the core of the plasma. The analysis includes the effects of beam formation, attenuation in the neutral gas surrounding the plasma, and attenuation in the plasma. In the course of this work, a numerical simulation and an analytical approximation for beam divergence are developed. The description is made sufficiently compact to yield accurate results in a time consistent with between-shot analysis.

  17. ITER Plasma at Ion Cyclotron Frequency Domain: The Fusion Alpha Particles Diagnostics Based on the Stimulated Raman Scattering of Fast Magnetosonic Wave off High Harmonic Ion Bernstein Modes

    Science.gov (United States)

    Stefan, V. Alexander

    2014-10-01

    A novel method for alpha particle diagnostics is proposed. The theory of stimulated Raman scattering, SRS, of the fast wave and ion Bernstein mode, IBM, turbulence in multi-ion species plasmas, (Stefan University Press, La Jolla, CA, 2008). is utilized for the diagnostics of fast ions, (4)He (+2), in ITER plasmas. Nonlinear Landau damping of the IBM on fast ions near the plasma edge leads to the space-time changes in the turbulence level, (inverse alpha particle channeling). The space-time monitoring of the IBM turbulence via the SRS techniques may prove efficient for the real time study of the fast ion velocity distribution function, spatial distribution, and transport. Supported by Nikola Tesla Labs., La Jolla, CA 92037.

  18. Plasma Biomarkers of Brain Injury as Diagnostic Tools and Outcome Predictors After Extracorporeal Membrane Oxygenation.

    Science.gov (United States)

    Bembea, Melania M; Rizkalla, Nicole; Freedy, James; Barasch, Noah; Vaidya, Dhananjay; Pronovost, Peter J; Everett, Allen D; Mueller, Gregory

    2015-10-01

    To determine if elevations in plasma brain injury biomarkers are associated with outcome at hospital discharge in children who require extracorporeal membrane oxygenation. Prospective observational study. Single tertiary-care academic center. Eighty children who underwent extracorporeal membrane oxygenation between June 2010 and December 2013. None. We measured six brain injury biomarkers (glial fibrillary acidic protein, monocyte chemoattractant protein 1/chemokine (C-C motif) ligand 2, neuron-specific enolase, S100b, intercellular adhesion molecule-5, and brain-derived neurotrophic factor) daily during extracorporeal membrane oxygenation, using an electrochemiluminescent multiplex assay. We recorded clinical, neuroimaging, and extracorporeal membrane oxygenation course data. We analyzed the association of biomarker concentrations with favorable versus unfavorable outcome at hospital discharge. Favorable outcome was defined as Pediatric Cerebral Performance Category 1, 2, or no change from baseline. Patients had a median age of 3 days (interquartile range, 1 d-10 mo), and 56% were male. Thirty-three of 80 (41%) had unfavorable outcome, and 22 of 70 (31%) had abnormal neuroimaging findings during or after extracorporeal membrane oxygenation. Peak concentrations were significantly higher in patients with unfavorable outcome than in those with favorable outcome for glial fibrillary acidic protein (p = 0.002), monocyte chemoattractant protein 1/chemokine (C-C motif) ligand 2 (p = 0.030), neuron-specific enolase (p = 0.006), and S100b (p = 0.015) and in patients with versus without abnormal neuroimaging findings for glial fibrillary acidic protein (p = 0.001) and intercellular adhesion molecule-5 (p = 0.001). The area under the receiver operator characteristic curve for unfavorable outcome was 0.73 for a noncollinear biomarker combination. After removing collinear biomarkers, the adjusted odds ratios for unfavorable outcome were 2.89 (95% CI, 1.09-7.73) for neuron

  19. Advances of plasma diagnostics with high-resolution spectroscopy of stellar coronae

    CERN Document Server

    Ness, J U

    2005-01-01

    X-ray emission from cool stars is an important tracer for stellar activity. The X-ray luminosity reflects different levels of activity and covers four orders of magnitude in stars of spectral types M-F. Low spectral resolution provided by X-ray observations of stellar coronae in the past allowed the determination of temperature distributions and elemental abundances making use of atomic databases (listing line emissivities and bremsstrahlung continuum for a given temperature structure). The new missions XMM-Newton and Chandra carry X-ray gratings providing sufficient spectral resolution to measure the fluxes of strategic emission lines. I describe the different approaches applicable to low-resolution and high-resolution spectra, especially focusing on the new grating spectra with X-ray lines. From only a few lines it is possible to determine plasma temperatures and associated densities, to check for any effects from resonant scattering, and to identify particular abundance anomalies. Line-based temperature- a...

  20. Diagnostic Performance of Plasma DNA Methylation Profiles in Lung Cancer, Pulmonary Fibrosis and COPD.

    Science.gov (United States)

    Wielscher, Matthias; Vierlinger, Klemens; Kegler, Ulrike; Ziesche, Rolf; Gsur, Andrea; Weinhäusel, Andreas

    2015-08-01

    Disease-specific alterations of the cell-free DNA methylation status are frequently found in serum samples and are currently considered to be suitable biomarkers. Candidate markers were identified by bisulfite conversion-based genome-wide methylation screening of lung tissue from lung cancer, fibrotic ILD, and COPD. cfDNA from 400 μl serum (n = 204) served to test the diagnostic performance of these markers. Following methylation-sensitive restriction enzyme digestion and enrichment of methylated DNA via targeted amplification (multiplexed MSRE enrichment), a total of 96 markers were addressed by highly parallel qPCR. Lung cancer was efficiently separated from non-cancer and controls with a sensitivity of 87.8%, (95%CI: 0.67-0.97) and specificity 90.2%, (95%CI: 0.65-0.98). Cancer was distinguished from ILD with a specificity of 88%, (95%CI: 0.57-1), and COPD from cancer with a specificity of 88% (95%CI: 0.64-0.97). Separation of ILD from COPD and controls was possible with a sensitivity of 63.1% (95%CI: 0.4-0.78) and a specificity of 70% (95%CI: 0.54-0.81). The results were confirmed using an independent sample set (n = 46) by use of the four top markers discovered in the study (HOXD10, PAX9, PTPRN2, and STAG3) yielding an AUC of 0.85 (95%CI: 0.72-0.95). This technique was capable of distinguishing interrelated complex pulmonary diseases suggesting that multiplexed MSRE enrichment might be useful for simple and reliable diagnosis of diverse multifactorial disease states.

  1. Implementation of a multichannel soft x-ray diagnostic for electron temperature measurements in TJ-II high-density plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Baiao, D.; Varandas, C. [Associacao EURATOM/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, 1049-001 Lisboa (Portugal); Medina, F.; Ochando, M.; Pastor, I. [Laboratorio Nacional de Fusion, Asociacion EURATOM-CIEMAT, 28040 Madrid (Spain); Molinero, A.; Chercoles, J. [Laboratorio General de Electronica y Automatica-CIEMAT, 28040 Madrid (Spain)

    2012-10-15

    Based on the multi-foil technique, a multichannel soft x-ray diagnostic for electron temperature measurements has been recently implemented in the TJ-II stellarator. The diagnostic system is composed by four photodiodes arrays with beryllium filters of different thickness. An in-vacuum amplifier board is coupled to each array, aiming at preventing induced noise currents. The Thomson scattering and the vacuum ultraviolet survey diagnostics are used for assessing plasma profiles and composition, being the analysis carried out with the radiation code IONEQ. The electron temperature is determined through the different signal-pair ratios with temporal and spatial resolution. The design and preliminary results from the diagnostic are presented.

  2. Combination of the ionic-to-atomic line intensity ratios from two test elements for the diagnostic of plasma temperature and electron number density in Inductively Coupled Plasma Atomic Emission Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tognoni, E. [Istituto per i Processi Chimico-Fisici, Area della Ricerca del Consiglio Nazionale delle Ricerche Via Moruzzi 1, 56124 Pisa (Italy)], E-mail: tognoni@ipcf.cnr.it; Hidalgo, M.; Canals, A. [Departamento de Quimica Analitica, Nutricion y Bromatologia. Universidad de Alicante. Apdo. 99, 03080, Alicante (Spain); Cristoforetti, G.; Legnaioli, S.; Salvetti, A.; Palleschi, V. [Istituto per i Processi Chimico-Fisici, Area della Ricerca del Consiglio Nazionale delle Ricerche Via Moruzzi 1, 56124 Pisa (Italy)

    2007-05-15

    In Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES) spectrochemical analysis, the MgII(280.270 nm)/MgI(285.213 nm) ionic to atomic line intensity ratio is commonly used as a monitor of the robustness of operating conditions. This approach is based on the univocal relationship existing between intensity ratio and plasma temperature, for a pure argon atmospheric ICP in thermodynamic equilibrium. In a multi-elemental plasma in the lower temperature range, the measurement of the intensity ratio may not be sufficient to characterize temperature and electron density. In such a range, the correct relationship between intensity ratio and plasma temperature can be calculated only when the complete plasma composition is known. We propose the combination of the line intensity ratios of two test elements (double ratio) as an effective diagnostic tool for a multi-elemental low temperature LTE plasma of unknown composition. In particular, the variation of the double ratio allows us discriminating changes in the plasma temperature from changes in the electron density. Thus, the effects on plasma excitation and ionization possibly caused by introduction of different samples and matrices in non-robust conditions can be more accurately interpreted. The method is illustrated by the measurement of plasma temperature and electron density in a specific analytic case.

  3. X-ray photoionized plasma diagnostics with Helium-like ions Application to Warm Absorber-Emitter in Active Galactic Nuclei

    CERN Document Server

    Porquet, D; Porquet, Delphine

    2000-01-01

    We present He-like line ratios (resonance, intercombination and forbiddenlines) for totally and partially photoionized media. For solar plasmas, theseline ratios are already widely used for density and temperature diagnostics ofcoronal (collisional) plasmas. In the case of totally and partiallyphotoionized plasmas, He-like line ratios allow for the determination of theionization processes involved in the plasma (photoionization with or without anadditional collisional ionization process), as well as the density and theelectronic temperature. With the new generation of X-ray satellites,Chandra/AXAF, XMM and Astro-E, it will be feasible to obtain both high spectralresolution and high sensitivity observations. Thus in the coming years, theratios of these three components will be measurable for a large number ofnon-solar objects. In particular, these ratios could be applied to the WarmAbsorber-Emitter, commonly present in Active Galactic Nuclei (AGN). A betterunderstanding of the Warm Absorber connection to other...

  4. Developing an edge-plasma diagnostic tool for the Globus-M tokamak based on measuring ratios of HeI lines

    Science.gov (United States)

    Timokhin, V. M.; Rykachevskii, A. I.; Miroshnikov, I. V.; Sergeev, V. Yu.; Kochergin, M. M.; Koval', A. N.; Mukhin, E. E.; Tolstyakov, S. Yu.; Voronin, A. V.

    2016-08-01

    A diagnostic technique that is based on measuring the ratios of neutral-helium line strengths has been developed for peripheral distributions of electron temperature and density of tokamak plasma. The main components of the technique are a four-channel filter-lens imaging polychromator (FLIP-4) and a Phantom Miro M110 high-speed camera for recording the images. The polychromator has been assembled, adjusted, and tested on an optical test bench. The optical system was installed on the spherical Globus-M tokamak. Some preliminary experiments were carried out. Images of the plasma-gun jet were obtained at neutralhelium lines.

  5. Talbot-Lau x-ray deflectometer electron density diagnostic for laser and pulsed power high energy density plasma experiments (invited)

    Science.gov (United States)

    Valdivia, M. P.; Stutman, D.; Stoeckl, C.; Mileham, C.; Begishev, I. A.; Theobald, W.; Bromage, J.; Regan, S. P.; Klein, S. R.; Muñoz-Cordovez, G.; Vescovi, M.; Valenzuela-Villaseca, V.; Veloso, F.

    2016-11-01

    Talbot-Lau X-ray deflectometry (TXD) has been developed as an electron density diagnostic for High Energy Density (HED) plasmas. The technique can deliver x-ray refraction, attenuation, elemental composition, and scatter information from a single Moiré image. An 8 keV Talbot-Lau interferometer was deployed using laser and x-pinch backlighters. Grating survival and electron density mapping were demonstrated for 25-29 J, 8-30 ps laser pulses using copper foil targets. Moiré pattern formation and grating survival were also observed using a copper x-pinch driven at 400 kA, ˜1 kA/ns. These results demonstrate the potential of TXD as an electron density diagnostic for HED plasmas.

  6. Talbot-Lau x-ray deflectometer electron density diagnostic for laser and pulsed power high energy density plasma experiments (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Valdivia, M. P., E-mail: mpvaldivia@pha.jhu.edu; Stutman, D. [Department of Physics and Astronomy, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Stoeckl, C.; Mileham, C.; Begishev, I. A.; Theobald, W.; Bromage, J.; Regan, S. P. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Klein, S. R. [Center for Laser Experimental Astrophysical Research, University of Michigan, Ann Arbor, Michigan 48105 (United States); Muñoz-Cordovez, G.; Vescovi, M.; Valenzuela-Villaseca, V.; Veloso, F. [Instituto de Física, Pontificia Universidad Católica de Chile, Macul, Santiago (Chile)

    2016-11-15

    Talbot-Lau X-ray deflectometry (TXD) has been developed as an electron density diagnostic for High Energy Density (HED) plasmas. The technique can deliver x-ray refraction, attenuation, elemental composition, and scatter information from a single Moiré image. An 8 keV Talbot-Lau interferometer was deployed using laser and x-pinch backlighters. Grating survival and electron density mapping were demonstrated for 25–29 J, 8–30 ps laser pulses using copper foil targets. Moiré pattern formation and grating survival were also observed using a copper x-pinch driven at 400 kA, ∼1 kA/ns. These results demonstrate the potential of TXD as an electron density diagnostic for HED plasmas.

  7. THE DIAGNOSTIC O VI ABSORPTION LINE IN DIFFUSE PLASMAS: COMPARISON OF NON-EQUILIBRIUM IONIZATION STRUCTURE SIMULATIONS TO FUSE DATA

    Energy Technology Data Exchange (ETDEWEB)

    De Avillez, Miguel A. [Department of Mathematics, University of Evora, R. Romao Ramalho 59, 7000 Evora (Portugal); Breitschwerdt, Dieter [Zentrum fuer Astronomie und Astrophysik, Technische Universitaet Berlin, Hardenbergstrasse 36, D-10623 Berlin (Germany)

    2012-12-20

    The nature of the interstellar O VI in the Galactic disk is studied by means of a multi-fluid hydrodynamical approximation, tracing the detailed time-dependent evolution of the ionization structure of the plasma. Our focus is to explore the signature of any non-equilibrium ionization condition present in the interstellar medium using the diagnostic O VI ion. A detailed comparison between the simulations and FUSE data is carried out by taking lines of sight (LOS) measurements through the simulated Galactic disk, covering an extent of 4 kpc from different vantage points. The simulation results bear a striking resemblance with the observations: (1) the N(O VI) distribution with distance and angle fall within the minimum and maximum values of the FUSE data; (2) the column density dispersion with distance is constant for all the LOS, showing a mild decrease at large distances; (3) O VI has a clumpy distribution along the LOS; and (4) the time-averaged midplane density for distances >400 pc has a value of (1.3-1.4) Multiplication-Sign 10{sup -8} cm{sup -3}. The highest concentration of O VI by mass occurs in the thermally stable (10{sup 3.9} K < T {<=} 10{sup 4.2} K; 20%) and unstable (10{sup 4.2} K < T < 10{sup 5} K; 50%) regimes, both well below its peak temperature in collisional ionization equilibrium, with the corresponding volume filling factors oscillating with time between 8%-20% and 4%-5%, respectively. These results may also be relevant for intergalactic metal absorption systems at high redshifts.

  8. An assessment of Fe xx-Fe xxii emission lines in SDO/EVE data as diagnostics for high-density solar flare plasmas using EUVE stellar observations

    Science.gov (United States)

    Keenan, F. P.; Milligan, R. O.; Mathioudakis, M.; Christian, D. J.

    2017-06-01

    The Extreme Ultraviolet Variability Experiment (EVE) on the Solar Dynamics Observatory obtains extreme-ultraviolet (EUV) spectra of the full-disc Sun at a spectral resolution of ˜1 Å and cadence of 10 s. Such a spectral resolution would normally be considered to be too low for the reliable determination of electron density (Ne) sensitive emission line intensity ratios, due to blending. However, previous work has shown that a limited number of Fe xxi features in the 90-160 Å wavelength region of EVE do provide useful Ne-diagnostics at relatively low flare densities (Ne ≃ 1011-1012 cm-3). Here, we investigate if additional highly ionized Fe line ratios in the EVE 90-160 Å range may be reliably employed as Ne-diagnostics. In particular, the potential for such diagnostics to provide density estimates for high Ne (˜1013 cm-3) flare plasmas is assessed. Our study employs EVE spectra for X-class flares, combined with observations of highly active late-type stars from the EUVE satellite plus experimental data for well-diagnosed tokamak plasmas, both of which are similar in wavelength coverage and spectral resolution to those from EVE. Several ratios are identified in EVE data, which yield consistent values of electron density, including Fe xx 113.35/121.85 and Fe xxii 114.41/135.79, with confidence in their reliability as Ne-diagnostics provided by the EUVE and tokamak results. These ratios also allow the determination of density in solar flare plasmas up to values of ˜1013 cm-3.

  9. Study on the plasma proteomic profiling by using surface enhanced laser desorption ionization time of flight mass spectrometry for setting up a diagnostic model of endometriosis

    Institute of Scientific and Technical Information of China (English)

    Liu Hai-yuan; Liu Chun-yan; Leng Jin-hua; Liu Zhu-feng; Sun Da-wei; Zhu Lan; Lang Jing-he; Zheng Yan-hua; Zhang Jian-zhong

    2007-01-01

    Objective: To determine the plasma proteomic profiling by using surface enhanced laser desorption ionization time of flight mass spectrometry (SELDI-TOF-MS) combined with bioinformatics for screening biomarkers of endometriosis and primarily setting up a diagnostic model of endometriosis.Method.Thirty-six patients with endometriosis diagnosed laparoscopically and thirty-five healthy controls were included in the study.Their serum were analyzed by SELDI and protein chip to generate protein profiling spectra.Student t test was used to compare the peak intensifies of the protein profiling results from the different groups.Biomarker Pattern Software was used to analyze the data between two groups and set up a diagnostic model for endometriosis.Protein profiling spectra from sixteen endometriosis patients and fifteen healthy controls were used double-blindedly to test the efficiency of the diagnostic model and generate the sensitivity and specificity of the model.Result: Fourteen abnormally expressed protein peaks were detected in the plasma of patients with endometriosis (P<0.01).The endometriosis diagnostic model was composed of three protein peaks.It correctly identified 33 of 36 patients with endometriosis and 29 of 35 controls in the training test.In the masked set 14 of 16 patients with endometriosis and 12 of 15 normal controls were correctly identified with sensitivity of 87.5% and specificity of 8o%.Conclusion: Patients with endometriosis have a unique cluster of proteins in plasma detected by SELDI.SELDI provides a new approach for screening novel biomarkers of endometriosis.Its utility in clinical practice need further study.

  10. Modeling of low-temperature plasmas generated using laser-induced breakdown spectroscopy: the ChemCam diagnostic tool on the Mars Science Laboratory Rover

    Science.gov (United States)

    Colgan, James

    2016-05-01

    We report on efforts to model the low-temperature plasmas generated using laser-induced breakdown spectroscopy (LIBS). LIBS is a minimally invasive technique that can quickly and efficiently determine the elemental composition of a target and is employed in an extremely wide range of applications due to its ease of use and fast turnaround. In particular, LIBS is the diagnostic tool used by the ChemCam instrument on the Mars Science Laboratory rover Curiosity. In this talk, we report on the use of the Los Alamos plasma modeling code ATOMIC to simulate LIBS plasmas, which are typically at temperatures of order 1 eV and electron densities of order 10 16 - 17 cm-3. At such conditions, these plasmas are usually in local-thermodynamic equilibrium (LTE) and normally contain neutral and singly ionized species only, which then requires that modeling must use accurate atomic structure data for the element under investigation. Since LIBS devices are often employed in a very wide range of applications, it is therefore desirable to have accurate data for most of the elements in the periodic table, ideally including actinides. Here, we discuss some recent applications of our modeling using ATOMIC that have explored the plasma physics aspects of LIBS generated plasmas, and in particular discuss the modeling of a plasma formed from a basalt sample used as a ChemCam standard1. We also highlight some of the more general atomic physics challenges that are encountered when attempting to model low-temperature plasmas. The Los Alamos National Laboratory is operated by Los Alamos National Security, LLC for the National Nuclear Security Administration of the U.S. Department of Energy under Contract No. DE-AC5206NA25396. Work performed in conjunction with D. P. Kilcrease, H. M. Johns, E. J. Judge, J. E. Barefield, R. C. Wiens, S. M. Clegg.

  11. Determination of state-to-state electron-impact rate coefficients between Ar excited states: a review of combined diagnostic experiments in afterglow plasmas

    Science.gov (United States)

    Zhu, Xi-Ming; Cheng, Zhi-Wen; Carbone, Emile; Pu, Yi-Kang; Czarnetzki, Uwe

    2016-08-01

    Electron-impact excitation processes play an important role in low-temperature plasma physics. Cross section and rate coefficient data for electron-impact processes from the ground state to excited states or between two excited states are required for both diagnostics and modeling works. However, the collisional processes between excited states are much less investigated than the ones involving the ground state due to various experimental challenges. Recently, a method for determining electron excitation rate coefficients between Ar excited states in afterglow plasmas was successfully implemented and further developed to obtain large sets of collisional data. This method combines diagnostics for electron temperature, electron density, and excited species densities and kinetic modeling of excited species, from which the electron excitation rate coefficients from one of the 1s states to the other 1s states or to one of 2p or 3p states are determined (states are in Paschen’s notation). This paper reviews the above method—namely the combined diagnostics and modeling in afterglow plasmas. The results from other important approaches, including electron-beam measurement of cross sections, laser pump-probe technique for measuring rate coefficients, and theoretical calculations by R-matrix and distorted-wave models are also discussed. From a comparative study of these results, a fitted mathematical expression of excitation rate coefficients is obtained for the electron temperature range of 1-5 eV, which can be used for the collisional-radiative modeling of low-temperature Ar plasmas. At last, we report the limitations in the present dataset and give some suggestions for future work in this area.

  12. Measurement of electron density of the plasma in the Tokamak TCABR, through Thomson scattering diagnostic; Medida da densidade eletronica do plasma no Tokamak TCABR, atraves do diagnostico Espalhamento Thomson

    Energy Technology Data Exchange (ETDEWEB)

    Jeronimo, Leonardo Cunha

    2013-07-01

    Over the last few years is remarkable, so increasingly evident the need for a new source of energy for mankind. One promising option is through nuclear fusion, where the plasma produced in the reactor can be converted into electrical energy. Therefore, knowing the characteristics of this plasma is very important to control it and understand it so desirable. One of the diagnostic options is called Thomson scattering . This is considered the most reliable method for the determination of important plasma parameters such as temperature and electron density, and may also help in the study and explanation of various internal mechanisms. The great advantage lies in the tact that they consist of a direct measurement and nonperturbative. But it is a diagnosis whose installation and execution is admittedly complex, limiting it only a few laboratories in the fíeld of fusion for the world. Among the main difficulties, wc can highlight the fact that the scattered signal is very small, thus requiring a large increase of the incident power. Moreover, the external physical conditions can cause mechanical vibrations that eliminate or minimize them as much as possible, is a great challenge, considering the optical micrometrically very sensitive and needs involved in the system. This work describes the entire process of installation and operation of Thomson scattering diagnostic in tokamak TCABR and through this diagnosis, we work on results of electron temperature, to finally be able to calculate the electron density of the plasma. (author)

  13. A Multifrequency Notch Filter for Millimeter Wave Plasma Diagnostics based on Photonic Bandgaps in Corrugated Circular Waveguides

    Directory of Open Access Journals (Sweden)

    Wagner D.

    2015-01-01

    Full Text Available Sensitive millimeter wave diagnostics need often to be protected against unwanted radiation like, for example, stray radiation from high power Electron Cyclotron Heating applied in nuclear fusion plasmas. A notch filter based on a waveguide Bragg reflector (photonic band-gap may provide several stop bands of defined width within up to two standard waveguide frequency bands. A Bragg reflector that reflects an incident fundamental TE11 into a TM1n mode close to cutoff is combined with two waveguide tapers to fundamental waveguide diameter. Here the fundamental TE11 mode is the only propagating mode at both ends of the reflector. The incident TE11 mode couples through the taper and is converted to the high order TM1n mode by the Bragg structure at the specific Bragg resonances. The TM1n mode is trapped in the oversized waveguide section by the tapers. Once reflected at the input taper it will be converted back into the TE11 mode which then can pass through the taper. Therefore at higher order Bragg resonances, the filter acts as a reflector for the incoming TE11 mode. Outside of the Bragg resonances the TE11 mode can propagate through the oversized waveguide structure with only very small Ohmic attenuation compared to propagating in a fundamental waveguide. Coupling to other modes is negligible in the non-resonant case due to the small corrugation amplitude (typically 0.05·λ0, where λ0 is the free space wavelength. A Bragg reflector for 105 and 140 GHz was optimized by mode matching (scattering matrix simulations and manufactured by SWISSto12 SA, where the required mechanical accuracy of ± 5 μm could be achieved by stacking stainless steel rings, manufactured by micro-machining, in a high precision guiding pipe. The two smooth-wall tapers were fabricated by electroforming. Several measurements were performed using vector network analyzers from Agilent (E8362B, ABmm (MVNA 8-350 and Rohde&Schwarz (ZVA24 together with frequency multipliers. The

  14. Characterization of a 20 kW helicon source for fusion relevant plasma-surface interactions using microwave and electrostic diagnostics

    Science.gov (United States)

    Caneses, Juan Francisco; Blackwell, Boyd; Guenette, Mathew; Corr, Cormac

    2013-10-01

    The MAGnetized Plasma Interaction Experiment (MAGPIE) is a non-uniform axial magnetic field helicon source built to study fusion relevant plasma-surface interactions. In this work we describe its operation with a new 20 kW pulsed RF source in H2 and He under various discharge configurations. Diagnostics such as RF double probes and a 140 GHz heterodyne Michelson microwave interferometer are used to characterize the performance of the device over a wide range of operational regimes. During initial characterization we have measured plasma densities in excess of 1 × 1019 m-3 in H2 at 12 kW of RF power. Finally, we report on recent work conducted in MAGPIE in close collaboration with the Australian Nuclear Science and Technology Organisation (ANSTO) and the Plasma Research Laboratory (PRL) where biased material samples are subjected to H2 plasma. These samples are then analyzed ex-suti using a variety of material characterization techniques. Materials being investigated include graphite, diamond and tungsten.

  15. A systematic review of the literature examining the diagnostic efficacy of measurement of fractionated plasma free metanephrines in the biochemical diagnosis of pheochromocytoma

    Directory of Open Access Journals (Sweden)

    Thabane Lehana

    2004-06-01

    Full Text Available Abstract Background Fractionated plasma metanephrine measurements are commonly used in biochemical testing in search of pheochromocytoma. Methods We aimed to critically appraise the diagnostic efficacy of fractionated plasma free metanephrine measurements in detecting pheochromocytoma. Nine electronic databases, meeting abstracts, and the Science Citation Index were searched and supplemented with previously unpublished data. Methodologic and reporting quality was independently assessed by two endocrinologists using a checklist developed by the Standards for Reporting of Diagnostic Studies Accuracy Group and data were independently abstracted. Results Limitations in methodologic quality were noted in all studies. In all subjects (including those with genetic predisposition: the sensitivities for detection of pheochromocytoma were 96%–100% (95% CI ranged from 82% to 100%, whereas the specificities were 85%–100% (95% CI ranged from 78% to 100%. Statistical heterogeneity was noted upon pooling positive likelihood ratios when those with predisposition to disease were included (p Conclusion Negative plasma fractionated free metanephrine measurements are effective in ruling out pheochromocytoma. However, a positive test result only moderately increases suspicion of disease, particularly when screening for sporadic pheochromocytoma.

  16. Tritium Plasma Experiment Upgrade and Improvement of Surface Diagnostic Capabilities at STAR Facility for Enhancing Tritium and Nuclear PMI Sciences

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, M.; Taylor, C. N.; Pawelko, R. J.; Cadwallader, L. C.; Merrill, B. J.

    2016-04-01

    The Tritium Plasma Experiment (TPE) is a unique high-flux linear plasma device that can handle beryllium, tritium, and neutron-irradiated plasma facing materials, and is the only existing device dedicated to directly study tritium retention and permeation in neutron-irradiated materials with tritium [M. Shimada et.al., Rev. Sci. Instru. 82 (2011) 083503 and and M. Shimada, et.al., Nucl. Fusion 55 (2015) 013008]. The plasma-material-interaction (PMI) determines a boundary condition for diffusing tritium into bulk PFCs, and the tritium PMI is crucial for enhancing fundamental sciences that dictate tritium fuel cycles and safety and are high importance to an FNSF and DEMO. Recently the TPE has undergone major upgrades in its electrical and control systems. New DC power supplies and a new control center enable remote plasma operations from outside of the contamination area for tritium, minimizing the possible exposure risk with tritium and beryllium. We discuss the electrical upgrade, enhanced operational safety, improved plasma performance, and development of optical spectrometer system. This upgrade not only improves operational safety of the worker, but also enhances plasma performance to better simulate extreme plasma-material conditions expected in ITER, Fusion Nuclear Science Facility (FNSF), and Demonstration reactor (DEMO). This work was prepared for the U.S. Department of Energy, Office of Fusion Energy Sciences, under the DOE Idaho Field Office contract number DE-AC07-05ID14517.

  17. A physical parameter method for the design of broad-band X-ray imaging systems to do coronal plasma diagnostics

    Science.gov (United States)

    Kahler, S.; Krieger, A. S.

    1978-01-01

    The technique commonly used for the analysis of data from broad-band X-ray imaging systems for plasma diagnostics is the filter ratio method. This requires the use of two or more broad-band filters to derive temperatures and line-of-sight emission integrals or emission measure distributions as a function of temperature. Here an alternative analytical approach is proposed in which the temperature response of the imaging system is matched to the physical parameter being investigated. The temperature response of a system designed to measure the total radiated power along the line of sight of any coronal structure is calculated. Other examples are discussed.

  18. Diagnostics of electron temperature and ions distribution in expanding Al plasmas pumped by a ns-pulsed 1.06μm laser

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Resonance lines are extensively used to diagnose electronic temperature Te and ions distribution. However, the analysis of the x-ray spectroscopy emitted from plasmas produced by a ns laser usually needs the help of a code or some assumptions. In this paper, a diagnostic idea of using line-pairs emitted from a doubly-excited state is proposed. By using the method presented in this paper, Te and the fractional population ratio of bare nuclei and H-like ions are directly obtained from the emission intensity ratios.

  19. Complex polarization-phase and spatial-frequency selections of laser images of blood-plasma films in diagnostics of changes in their polycrystalline structure

    Science.gov (United States)

    Ushenko, Yu. A.; Angelskii, P. O.; Dubolazov, A. V.; Karachevtsev, A. O.; Sidor, M. I.; Mintser, O. P.; Oleinichenko, B. P.; Bizer, L. I.

    2013-10-01

    We present a theoretical formalism of correlation phase analysis of laser images of human blood plasma with spatial-frequency selection of manifestations of mechanisms of linear and circular birefringence of albumin and globulin polycrystalline networks. Comparative results of the measurement of coordinate distributions of the correlation parameter—the modulus of the degree of local correlation of amplitudes—of laser images of blood plasma taken from patients of three groups—healthy patients (donors), rheumatoid-arthritis patients, and breast-cancer patients—are presented. We investigate values and ranges of change of statistical (the first to fourth statistical moments), correlation (excess of autocorrelation functions), and fractal (slopes of approximating curves and dispersion of extrema of logarithmic dependences of power spectra) parameters of coordinate distributions of the degree of local correlation of amplitudes. Objective criteria for diagnostics of occurrence and differentiation of inflammatory and oncological states are determined.

  20. Low-energy x-ray and electron physics and applications to diagnostics development for laser-produced plasma research. Final report, April 30, 1980-April 29, 1981

    Energy Technology Data Exchange (ETDEWEB)

    Henke, B.L.

    1981-08-01

    This final report describes a collaborative extension of an ongoing research program in low-energy x-ray and electron physics into particular areas of immediate need for the diagnostics of plasmas as involved in laser-produced fusion research. It has been for the continued support for one year of a post-doctoral research associate and for three student research assistants who have been applied to the following specific efforts: (1) the continuation of our research on the absolute characterization of x-ray photocathode systems for the 0.1 to 10 keV photon energy region. The research results were applied collaboratively to the design, construction and calibration of photocathodes for time-resolved detection with the XRD and the streak and framing cameras; (2) the design, construction and absolute calibration of optimized, bolt-on spectrographs for the absolute measurement of laser-produced plasma spectra.

  1. In-situ optical emission spectroscopy diagnostic of plasma ignition impact on crystalline silicon passivation by a-Si:H films

    Science.gov (United States)

    Meddeb, Hosny; Bearda, Twan; Abdulraheem, Yaser; Dimassi, Wissem; Ezzaouia, Hatem; Gordon, Ivan; Szlufcik, Jozef; Poortmans, Jef

    2016-08-01

    The influence of the plasma ignition condition during PECVD deposition from a silane/hydrogen mixture on the amorphous silicon passivation of crystalline silicon surface is investigated. The changes in this process step mainly consist in varying the power density for very brief durations in between 1 s and 3 s. We find that the ignition phase contributes significantly in the film growth, especially in the a-Si:H/c-Si interface formation. In particular, the deposition rate increases with ignition power density. TEM cross-section inspection presents a rougher a-Si:H/c-Si interface with higher plasma power and thus, a tendency for nano-clusters formation caused by the crystalline nature of the substrate. In-situ plasma diagnostics reveal the gradual raise up of IHa*/ISiH* with the power density leading to worse SiH* abstraction to the surface. Whereas, time-resolved optical emission spectroscopy explains the possible recombination mechanism in the plasma due to higher-silane related reactive species (HSRS) formation via polymerization reactions. Our results point out that the ignition conditions with a rather low power for longer time give the best passivation, resulting an effective lifetime up to 9 ms.

  2. Spectral diagnostics of a vapor-plasma plume produced during welding titanium with a high-power ytterbium fiber laser

    Science.gov (United States)

    Uspenskiy, S. A.; Petrovskiy, V. N.; Bykovskiy, D. P.; Mironov, V. D.; Prokopova, N. M.; Tret'yakov, E. V.

    2015-03-01

    This work is devoted to the research of welding plume during high power ytterbium fiber laser welding of a titanium alloy in the Ar shielding gas environment. High speed video observation of a vapor-plasma plume for visualization of processes occurring at laser welding was carried out. The coefficient of the inverse Bremsstrahlung absorption of laser radiation is calculated for a plasma welding plume by results of spectrometer researches. The conclusion deals with the impact of plasma on a high-power fiber laser radiation.

  3. Diagnostics of an AC driven atmospheric pressure non-thermal plasma jet and its use for radially directed jet array

    Science.gov (United States)

    Zhu, W.; Wang, R.

    2017-08-01

    An alternating current atmospheric pressure plasma jet is generated with noble gas or noble gas/oxygen admixture as working gas. A "core plasma filament" is observed at the center of the dielectric tube and extends to the plasma jet at higher peak-to-peak voltages. This type of plasma jet is believed to be of the same nature with the reported plasma bullet driven by pulsed DC power sources. Double current probes are used to assess the speed of the plasma bullet and show that the speed is around 104-105 m/s. The time dependence of the downstream bullet speed is attributed to the gas heating and in turn the increase of the reduced electric field E/N. Optical emission spectra show the dependence of helium and oxygen emission intensities on the concentration of oxygen additive in the carrier gas, with peak values found at 0.5% O2. Multiple radial jets are realized on dielectric tubes of different sizes. As a case study, one of these multi-jet devices is used to treat B. aureus on the inner surface of a plastic beaker and is shown to be more effective than a single jet.

  4. A new beam emission polarimetry diagnostic for measuring the magnetic field line angle at the plasma edge of ASDEX Upgrade

    Science.gov (United States)

    Viezzer, E.; Dux, R.; Dunne, M. G.

    2016-11-01

    A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line Dα. The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.

  5. A new beam emission polarimetry diagnostic for measuring the magnetic field line angle at the plasma edge of ASDEX Upgrade.

    Science.gov (United States)

    Viezzer, E; Dux, R; Dunne, M G

    2016-11-01

    A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line Dα. The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.

  6. A new beam emission polarimetry diagnostic for measuring the magnetic field line angle at the plasma edge of ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Viezzer, E., E-mail: eleonora.viezzer@ipp.mpg.de, E-mail: eviezzer@us.es [Max-Planck-Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Department of Atomic, Molecular, and Nuclear Physics, University of Seville, Avda. Reina Mercedes, 41012 Seville (Spain); Dux, R.; Dunne, M. G. [Max-Planck-Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany)

    2016-11-15

    A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line D{sub α}. The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.

  7. Plasma chemistry and diagnostic in an Ar-N{sub 2}-H{sub 2} microwave expanding plasma used for nitriding treatments

    Energy Technology Data Exchange (ETDEWEB)

    Touimi, S; Jauberteau, J L; Jauberteau, I; Aubreton, J, E-mail: jean-louis.jauberteau@unilim.f [SPCTS-UMR 6638 CNRS, Faculte des Sciences, 123 av A. Thomas, 87060 Limoges (France)

    2010-05-26

    This paper reports on the mass spectrometry analysis performed downstream a microwave discharge in an Ar-N{sub 2}-H{sub 2} gas mixture under nitriding conditions. Investigations are focused on the main simple radicals NH{sub 2}, NH and N, and on the molecular species NH{sub 3} and N{sub 2}H{sub 2} produced. Because of wall desorptions due to catalytic effects, we must develop a specific method taking into account both wall desorption and the dissociative ionization effects in order to correct the mass spectrometer signal intensity. The relative concentrations of the above-mentioned species are studied in various gas mixtures. Correlations are made between the plasma chemistry and the plasma parameters (electron density and energy electron distribution function), measured by means of a Langmuir probe spatially resolved within the plasma expansion. These results show the efficiency of ternary gas mixtures (Ar-N{sub 2}-H{sub 2}) in producing electrons and N{sub x}H{sub y} species used in plasma nitriding processes.

  8. Research support for plasma diagnostics on Elmo Bumpy Torus: diamagnetic measurements and data analysis, and development of ring models for realistic representation of fields near the plasma

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, K.H.; Steimle, R.F.

    1984-10-01

    Theoretical and experimental studies relating to the diamagnetism of the EBT electron rings have contributed to a better understanding of ring energy and geometry. The primary experimental effort during the past year was the taking of data using the UMR Hall Effect Diamagnetic Diagnostic instrument with the probes mounted along the horizontal midplane at the large major radius position of an EBT cavity. Analysis of this data has confirmed earlier indications of an electron ring component being present near the cavity wall.

  9. Intermediate frequency band digitized high dynamic range radiometer system for plasma diagnostics and real-time Tokamak control

    NARCIS (Netherlands)

    Bongers, WA.; Van Beveren, V.; Thoen, D.J.; Nuij, P.J.W.M.; De Baar, M.R.; Donné, A.J.H.; Westerhof, E.; Goede, A.P.H.; Krijger, B.; Van den Berg, M.A.; Kantor, M.; Graswinckel, M.F.; Hennen, B.A.; Schüller, F.C.

    2011-01-01

    An intermediate frequency (IF) band digitizing radiometer system in the 100–200 GHz frequency range has been developed for Tokamak diagnostics and control, and other fields of research which require a high flexibility in frequency resolution combined with a large bandwidth and the retrieval of the f

  10. Spectrum response and analysis of 77 GHz band collective Thomson scattering diagnostic for bulk and fast ions in LHD plasmas

    DEFF Research Database (Denmark)

    Nishiura, M.; Kubo, S.; Tanaka, K.

    2014-01-01

    A collective Thomson scattering (CTS) diagnostic was developed and used to measure the bulk and fast ions originating from 180 keV neutral beams in the Large Helical Device (LHD). Electromagnetic waves from a gyrotron at 77 GHz with 1 MW power output function as both the probe and electron cyclot...

  11. Particle sources with high-intensity lasers: a tool for plasma diagnostics and an innovative source for applications; Sources de particules avec des lasers de haute intensite: un outil pour les diagnostics plasma et une source innovante pour les applications

    Energy Technology Data Exchange (ETDEWEB)

    Fritzler, S

    2003-09-15

    This work is an experimental study on particle generation with high-intensity lasers. This document is divided into 4 parts, whereas the first is dedicated to theoretical basics of particle generation and acceleration mechanisms during relativistic laser plasma interactions, the 3 other parts cover experimental studies on neutron, electron as well as proton generation. In the first part basic laser and plasma characteristics will be introduced as well as physical processes of interest during the interaction of a relativistic high-intensity laser with an underdense / overdense plasma. In the second part we introduce methodological basics of neutron generation by D(d,n)He{sup 3} reactions since this can reveal information about ion kinetics and possible ion heating mechanisms in plasmas. Subsequently the set-up for this experiment, pursued in the underdense regime, will be described in detail. The experimental results will be discussed for the gas jet interaction as well as for the beam target model since it was deduced that plasma ions are heated during the interaction to fusion temperatures of about 1 keV. The third part describes the generation of an electron beam with an energy up to 200 MeV in a new regime termed 'forced laser Wakefield'. Here, the presented experimental results were for the first time fully explained and even extended by the numerical modelling of this interaction in terms of energy, yield, angular divergence, emittance as well as bunch length of this electron beam. In the last part we present a 10 MeV proton beam generation using foil targets and a 10 Hz laser. Again the kinematic simulation of this experiment is in agreement with the experimental results by means of yield and angular divergence.

  12. Verification of optical diagnostic methods in H{sub 2}/D{sub 2} - plasmas; Verifikation von optischen Diagnostikmethoden an H{sub 2}/D{sub 2} - Plasmen

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, Stephan

    2010-12-02

    For the neutral beam injection of the fusion experiment ITER negative deuterium ions have to be extracted from an ion source, accelerated to 1 MeV and subsequently neutralized. To control the plasma processes of the non-thermal hydrogen low temperature plasmas in the ion sources the knowledge of the plasma parameters like electron temperature and electron density is necessary. Among the required diagnostic methods the optical emission spectroscopy has one of the simplest setups which allows non-invasive and in situ measurements of the parameters. Within the scope of this thesis a modular diode system was developed, which allows together with systematically verified and improved optical diagnostic methods a time resolved online monitoring of the plasma parameters. The verification was carried out in stable and reproducible electron cyclotron resonance plasmas. These plasmas allows a simple comparison between the optical emission spectroscopy and various reference methods in a large parameter range of electron temperature and electron density. In order to verify the effective population densities from collisional radiative models and the deduced emission rate coefficients reference measurements were carried out using a Langmuir probe, a double probe, the Boyd-Twiddy-Method, interferometry, laser detachment, a mass spectrometer and already verified optical diagnostic methods of diagnostic gases like helium and argon. By a correction of the used collisional radiative model the determination of the electron density was significantly improved. (orig.)

  13. Spectral diagnostics of a vapor-plasma plume produced during welding with a high-power ytterbium fiber laser

    Science.gov (United States)

    Uspenskiy, S. A.; Shcheglov, P. Yu.; Petrovskiy, V. N.; Gumenyuk, A. V.; Rethmeier, M.

    2013-07-01

    We have conducted spectroscopic studies of the welding plasma formed in the process of welding with an ytterbium fiber laser delivering output power of up to 20 kW. The influence of shielding gases (Ar, He) on different parts of the welding plume is investigated. The absorption coefficient of the laser radiation by the welding-plume plasma is estimated. Scattering of 532-nm probe radiation from particles of the condensed metal vapor within the caustic of a high-power fiber laser beam is measured. Based on the obtained results, conclusions are made on the influence of the plasma formation and metal vapor condensation on the radiation of the high-power fiber laser and the stability of the welding process.

  14. Batch processing of overlapping molecular spectra as a tool for spatio-temporal diagnostics of power modulated microwave plasma jet

    Science.gov (United States)

    Voráč, Jan; Synek, Petr; Potočňáková, Lucia; Hnilica, Jaroslav; Kudrle, Vít

    2017-02-01

    Power modulated microwave plasma jet operating in argon at atmospheric pressure was studied by spatio-temporally resolved optical emission spectroscopy (OES) in order to clarify the influence of modulation on plasma parameters. OES was carried out in OH, NH, N2 and {{{N}}}2+ spectral regions using a spectrometer with intensified CCD detector synchronised with 101–103 Hz sine modulating signal. A special software, able to fit even the overlapping spectra, was developed to batch process the massive datasets produced by this spatio-temporal study. Results show that studied species with the exception of {{{N}}}2+ have balanced rotational and vibrational temperatures across the modulation frequencies. Significant influence of modulation can be clearly observed on temperature spatial gradients. Whereas for low modulation frequencies where the temperatures reach sharp maxima upon discharge tip, the high frequency modulation produces thermally homogeneous plasma.

  15. Microwave diagnostic for the determination of the electron temperature of a low density shock-heated argon plasma

    Science.gov (United States)

    Schneider, C. P.; Exberger, R. J.

    1978-01-01

    The diffraction, defocusing and beam bending effects of microwaves transmitted through a bounded shock-heated argon plasma with low electron density are investigated with the purpose of developing an accurate method for electron temperature (Te) determination. This report describes the evaluation technique and presents results for an argon plasma with pressure between 3 and 10 torr, and T2 between 5500 and 9500 K. The electron temperature values obtained have a range of uncertainty between -20% and +10% only. The electron temperature is equal or lower by approximately 1000 K in comparison to the heavy particle temperature (T2).

  16. A 'multi-colour' SXR diagnostic for time and space-resolved measurements of electron temperature, MHD activity and particle transport in MCF plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Delgado-Aparicio, L F [Johns Hopkins University, Department of Physics and Astronomy, Baltimore, MD 21218 (United States); Stutman, D [Johns Hopkins University, Department of Physics and Astronomy, Baltimore, MD 21218 (United States); Tritz, K [Johns Hopkins University, Department of Physics and Astronomy, Baltimore, MD 21218 (United States); Finkenthal, M [Johns Hopkins University, Department of Physics and Astronomy, Baltimore, MD 21218 (United States); Bell, R [Princeton Plasma Physics Laboratory, Princeton, NJ 08543-0451 (United States); Gates, D [Princeton Plasma Physics Laboratory, Princeton, NJ 08543-0451 (United States); Kaita, R [Princeton Plasma Physics Laboratory, Princeton, NJ 08543-0451 (United States); LeBlanc, B [Princeton Plasma Physics Laboratory, Princeton, NJ 08543-0451 (United States); Maingi, R [Oak Ridge National Laboratory/UT-Battelle, Oak Ridge, TN 37831 (United States); Yuh, H [Nova Photonics, Inc., One Oak Place, Princeton, NJ 08540 (United States); Levinton, F [Nova Photonics, Inc., One Oak Place, Princeton, NJ 08540 (United States); Heidbrink, W [University of California-Irvine, Department of Physics and Astronomy, Irvine, CA 92697 (United States)

    2007-08-01

    A fast ({<=}0.1 ms) and compact 'multi-colour' soft x-ray array has been developed for time and space-resolved electron temperature (T{sub e}) measurements in magnetically confined fusion (MCF) plasmas. The electron temperature is obtained by modelling the slope of the continuum radiation from ratios of the available 1D-Abel inverted radial emissivity profiles over different energy ranges, with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints or need of shot-to-shot reproducibility. This technique has been used to perform fast T{sub e} measurements in the National Spherical Torus Experiment (NSTX), avoiding the limitations imposed by the well-known multi-point Thompson scattering, electron cyclotron emission and electron Bernstein wave mode conversion diagnostics. The applicability of this 'multi-colour' technique for magnetohydrodynamic (MHD) mode recognition and a variety of perturbative electron and impurity transport studies in MCF plasmas is also discussed. Reconstructed 'multi-colour' emissivity profiles for a variety of NSTX scenarios are presented here for the first time.

  17. Space-and time-resolved diagnostics of the ENEA EUV discharge-produced-plasma source used for metrology and other applications

    Institute of Scientific and Technical Information of China (English)

    S.Bollanti; P.Di Lazzaro; F.Flora; L.Mezi; D.Murra; A.Torre

    2015-01-01

    A discharge-produced-plasma(DPP) source emitting in the extreme ultraviolet(EUV) spectral region is running at the ENEA Frascati Research Centre. The plasma is generated in low-pressure xenon gas and efficiently emits 100-ns duration radiation pulses in the 10–20-nm wavelength range, with an energy of 20 m J/shot/sr at a 10-Hz repetition rate. The complex discharge evolution is constantly examined and controlled with electrical measurements, while a nsgated CCD camera allowed observation of the discharge development in the visible, detection of time-resolved plasmacolumn pinching, and optimization of the pre-ionization timing. Accurately calibrated Zr-filtered PIN diodes are used to monitor the temporal behaviour and energy emission of the EUV pulses, while the calibration of a dosimetric film allows quantitative imaging of the emitted radiation. This comprehensive plasma diagnostics has demonstrated its effectiveness in suitably adjusting the source configuration for several applications, such as exposures of photonic materials and innovative photoresists.

  18. Wave and plasma measurements and GPS diagnostics of the main ionospheric trough as a hybrid method used for Space Weather purposes

    Directory of Open Access Journals (Sweden)

    H. Rothkaehl

    2008-02-01

    Full Text Available The region of the main ionospheric trough is a unique region of the ionosphere, where different types of waves and instabilities can be generated. This region of the ionosphere acts like a lens, focusing a variety of indicators from the equator of plasmapause and local ionospheric plasma. This paper reports the results of monitoring the mid-latitude trough structure, dynamics and wave activity. For these purposes, the data gathered by the currently-operating DEMETER satellite and past diagnostics located on IK-19, Apex, and MAGION-3 spacecraft, as well as TEC measurements were used. A global-time varying picture of the ionospheric trough was reconstructed using the sequence of wave spectra registered and plasma measurements in the top-side ionosphere. The authors present the wave activity from ULF frequency band to the HF frequency detected inside the trough region and discuss its properties during geomagnetic disturbances. It is thought that broadband emissions are correlated with low frequency radiation, which is excited by the wave-particle interaction in the equatorial plasmapause and moves to the ionosphere along the geomagnetic field line. In the ionosphere, the suprathermal electrons can interact with these electrostatic waves and excite electron acoustic waves or HF longitudinal plasma waves.

    Furthermore, the electron density trough can provide useful data on the magnetosphere ionosphere dynamics and morphology and, in consequence, can be used for Space Weather purposes.

  19. Spatially resolved measurements and diagnostics of digitally controlled rotating field pulsed plasma operated in helium at 20 kHz

    Science.gov (United States)

    Giersz, Jacek; Jankowski, Krzysztof; Reszke, Edward

    2017-04-01

    Using optical emission spectrometry, fundamental properties are investigated of a stable, planar atmospheric pressure micro discharge, several dozen microliters in volume, driven by a digitally controlled 20 kHz rotating microsecond pulsed power. The discharge is generated by rectangular wave pulses using helium as the working gas. At a low cost, the digitally controlled plasma source produces a highly symmetrical, non-stationary helium discharge maintained in open air within 5 electrodes positioned in the plane toward the center. It has been shown that the geometrical shapes of the momentary discharges, which occur between the electrodes, are not arc-like shaped, but rather have a diffusive character and the resulting plasma can become doughnut-like in shape. Rotational and vibrational temperatures from OH and N2 bands, excitation temperatures from He lines and ionization temperatures from Ca lines, as well as electron number densities from Hβ Stark broadening have been estimated along the plasma diameter using axial viewing. The results demonstrated that Texc (He) reaches stable value of 3800 K for selected plasma generation conditions (one anode and two cathodes commutation mode, cathode pulse width 8 microseconds, supplied power 200 W, helium gas flow 1 L·min- 1), while the Trot (OH) is considerably lower (1700 K). The electron number density has been evaluated to be (1.7-3.3) × 1014 cm- 3 and both Tion (Ca) and Tvib (N2) varied, throughout in the 4500-5100 K and 4000-4800 K ranges respectively, reaching its peak value near 2 mm off the plasma axis. Spatial measurements revealed symmetrical distribution of the plasma parameters, while the measurements of calcium and nitrogen ionic emission confirmed symmetrical doughnut shape of the discharge. Moreover, the processes running inside the discharge and their interaction with the surrounding atmosphere have been described in accordance to the recorded spectra. Spectroscopic observation has shown the existence of

  20. A temporally and spatially resolved electron density diagnostic method for the edge plasma based on Stark broadening

    Science.gov (United States)

    Zafar, A.; Martin, E. H.; Shannon, S. C.; Isler, R. C.; Caughman, J. B. O.

    2016-11-01

    An electron density diagnostic (≥1010 cm-3) capable of high temporal (ms) and spatial (mm) resolution is currently under development at Oak Ridge National Laboratory. The diagnostic is based on measuring the Stark broadened, Doppler-free spectral line profile of the n = 6-2 hydrogen Balmer series transition. The profile is then fit to a fully quantum mechanical model including the appropriate electric and magnetic field operators. The quasi-static approach used to calculate the Doppler-free spectral line profile is outlined here and the results from the model are presented for H-δ spectra for electron densities of 1010-1013 cm-3. The profile shows complex behavior due to the interaction between the magnetic substates of the atom.

  1. BRAF Mutation Testing in Cell-Free DNA from the Plasma of Patients with Advanced Cancers Using a Rapid, Automated Molecular Diagnostics System.

    Science.gov (United States)

    Janku, Filip; Huang, Helen J; Claes, Bart; Falchook, Gerald S; Fu, Siqing; Hong, David; Ramzanali, Nishma M; Nitti, Giovanni; Cabrilo, Goran; Tsimberidou, Apostolia M; Naing, Aung; Piha-Paul, Sarina A; Wheler, Jennifer J; Karp, Daniel D; Holley, Veronica R; Zinner, Ralph G; Subbiah, Vivek; Luthra, Rajyalakshmi; Kopetz, Scott; Overman, Michael J; Kee, Bryan K; Patel, Sapna; Devogelaere, Benoit; Sablon, Erwin; Maertens, Geert; Mills, Gordon B; Kurzrock, Razelle; Meric-Bernstam, Funda

    2016-06-01

    Cell-free (cf) DNA from plasma offers an easily obtainable material for BRAF mutation analysis for diagnostics and response monitoring. In this study, plasma-derived cfDNA samples from patients with progressing advanced cancers or malignant histiocytosis with known BRAF(V600) status from formalin-fixed paraffin-embedded (FFPE) tumors were tested using a prototype version of the Idylla BRAF Mutation Test, a fully integrated real-time PCR-based test with turnaround time about 90 minutes. Of 160 patients, BRAF(V600) mutations were detected in 62 (39%) archival FFPE tumor samples and 47 (29%) plasma cfDNA samples. The two methods had overall agreement in 141 patients [88%; κ, 0.74; SE, 0.06; 95% confidence interval (CI), 0.63-0.85]. Idylla had a sensitivity of 73% (95% CI, 0.60-0.83) and specificity of 98% (95% CI, 0.93-1.00). A higher percentage, but not concentration, of BRAF(V600) cfDNA in the wild-type background (>2% vs. ≤ 2%) was associated with shorter overall survival (OS; P = 0.005) and in patients with BRAF mutations in the tissue, who were receiving BRAF/MEK inhibitors, shorter time to treatment failure (TTF; P = 0.001). Longitudinal monitoring demonstrated that decreasing levels of BRAF(V600) cfDNA were associated with longer TTF (P = 0.045). In conclusion, testing for BRAF(V600) mutations in plasma cfDNA using the Idylla BRAF Mutation Test has acceptable concordance with standard testing of tumor tissue. A higher percentage of mutant BRAF(V600) in cfDNA corresponded with shorter OS and in patients receiving BRAF/MEK inhibitors also with shorter TTF. Mol Cancer Ther; 15(6); 1397-404. ©2016 AACR.

  2. Simulation results for PLATO: a prototype hybrid X-ray photon counting detector with a low energy threshold for fusion plasma diagnostics

    Science.gov (United States)

    Habib, A.; Menouni, M.; Pangaud, P.; Fenzi, C.; Colledani, G.; Moureau, G.; Escarguel, A.; Morel, C.

    2017-01-01

    PLATO is a prototype hybrid X-ray photon counting detector that has been designed to meet the specifications for plasma diagnostics for the WEST tokamak platform (Tungsten (W) Environment in Steady-state Tokamak) in southern France, with potential perspectives for ITER. PLATO represents a customized solution that fulfills high sensitivity, low dispersion and high photon counting rate. The PLATO prototype matrix is composed of 16 × 18 pixels with a 70 μm pixel pitch. New techniques have been used in analog sensitive blocks to minimize noise coupling through supply rails and substrate, and to suppress threshold dispersion across the matrix. The PLATO ASIC is designed in CMOS 0.13 μm technology and was submitted for a fabrication run in June 2016. The chip is designed to be bump-bonded to a silicon sensor. This paper presents pixel architecture as well as simulation results while highlighting novel solutions.

  3. Plasma diagnostics of an Ar/NH{sub 3} direct-current reactive magnetron sputtering discharge for SiN{sub x} deposition

    Energy Technology Data Exchange (ETDEWEB)

    Henry, F., E-mail: Fhenry@ulb.ac.be; Duluard, C.Y.; Batan, A.; Reniers, F., E-mail: Freniers@ulb.ac.be

    2012-08-01

    We have performed the deposition of silicon nitride thin films with the DC reactive magnetron sputtering technique from a silicon target in an Ar/NH{sub 3} gas mixture. Usually, the control of the process is carried out with discharge voltage measurements, which give information on the nature of the sputtering mode: metallic or reactive. To have a more complete view of the sputtering process, we have performed X-ray photoelectron spectroscopy (XPS) to investigate the chemistry of the silicon target racetrack and optical emission spectroscopy (OES) to investigate the Ar/NH{sub 3} gas phase near the target surface. When the NH{sub 3} molar fraction is increased, XPS measurements reveal the progressive formation of a silicon nitride layer on the target surface, thereby demonstrating a continuous transition to the reactive mode. OES measurements have highlighted the presence of several species which, according to the literature, are believed to be directly sputtered from the surface of the target: Si, SiH and SiN. Their intensities could be related to the chemical state of the target surface and provide a better insight into the sputtering process on the target surface. - Highlights: Black-Right-Pointing-Pointer Plasma diagnostics of Ar/NH{sub 3} DC reactive magnetron sputtering. Black-Right-Pointing-Pointer Multiple diagnostic techniques. Black-Right-Pointing-Pointer Poisoning of the target by formation of silicon nitride layer. Black-Right-Pointing-Pointer Relation between the light emitted by the plasma and the surface state of the target.

  4. Eight-channel Kirkpatrick-Baez microscope for multiframe x-ray imaging diagnostics in laser plasma experiments.

    Science.gov (United States)

    Yi, Shengzhen; Zhang, Zhe; Huang, Qiushi; Zhang, Zhong; Mu, Baozhong; Wang, Zhanshan; Fang, Zhiheng; Wang, Wei; Fu, Sizu

    2016-10-01

    Because grazing-incidence Kirkpatrick-Baez (KB) microscopes have better resolution and collection efficiency than pinhole cameras, they have been widely used for x-ray imaging diagnostics of laser inertial confinement fusion. The assembly and adjustment of a multichannel KB microscope must meet stringent requirements for image resolution and reproducible alignment. In the present study, an eight-channel KB microscope was developed for diagnostics by imaging self-emission x-rays with a framing camera at the Shenguang-II Update (SGII-Update) laser facility. A consistent object field of view is ensured in the eight channels using an assembly method based on conical reference cones, which also allow the intervals between the eight images to be tuned to couple with the microstrips of the x-ray framing camera. The eight-channel KB microscope was adjusted via real-time x-ray imaging experiments in the laboratory. This paper describes the details of the eight-channel KB microscope, its optical and multilayer design, the assembly and alignment methods, and results of imaging in the laboratory and at the SGII-Update.

  5. Eight-channel Kirkpatrick-Baez microscope for multiframe x-ray imaging diagnostics in laser plasma experiments

    Science.gov (United States)

    Yi, Shengzhen; Zhang, Zhe; Huang, Qiushi; Zhang, Zhong; Mu, Baozhong; Wang, Zhanshan; Fang, Zhiheng; Wang, Wei; Fu, Sizu

    2016-10-01

    Because grazing-incidence Kirkpatrick-Baez (KB) microscopes have better resolution and collection efficiency than pinhole cameras, they have been widely used for x-ray imaging diagnostics of laser inertial confinement fusion. The assembly and adjustment of a multichannel KB microscope must meet stringent requirements for image resolution and reproducible alignment. In the present study, an eight-channel KB microscope was developed for diagnostics by imaging self-emission x-rays with a framing camera at the Shenguang-II Update (SGII-Update) laser facility. A consistent object field of view is ensured in the eight channels using an assembly method based on conical reference cones, which also allow the intervals between the eight images to be tuned to couple with the microstrips of the x-ray framing camera. The eight-channel KB microscope was adjusted via real-time x-ray imaging experiments in the laboratory. This paper describes the details of the eight-channel KB microscope, its optical and multilayer design, the assembly and alignment methods, and results of imaging in the laboratory and at the SGII-Update.

  6. Study of laser-induced removal of co-deposits from tokamak plasma-facing components using ion diagnostics and optical spectroscopy

    Science.gov (United States)

    Wolowski, J.; Gasior, P.; Hoffman, J.; Kubkowska, M.; Rosinski, M.; Szymanski, Z.

    2010-10-01

    The paper presents studies of the application of ion diagnostics and optical spectroscopy for on-line measurement of the amount and characteristics of co-deposits from the laser-ablated surface of the plasma-facing components (e.g. graphite tiles). For removal of the co-deposit layer a repetitive Nd:YAG laser was used. Determination of the characteristics of ions emitted from the laser-illuminated targets was performed using ion collectors (on the basis of a time-of-flight method) and an optical spectrometer. The main ion stream parameters and spectral lines of deuterium and carbon or tungsten ions were measured depending on laser pulse parameters. The research proved that optical spectroscopy could be a convenient method for on-line observation of the co-deposited layer removal by means of laser ablation. In combination with the investigation of collected co-deposit dust, the performed study made it possible to state that laser-induced breakdown spectroscopy can be useful as a diagnostic method for the ablative co-deposited layer removal and the wall conditioning. The properties of modified surfaces of samples and collected dust (evaporated co-deposit) were determined using different measuring methods.

  7. Practical diagnostic approaches to composite plasma cell neoplasm and low grade B-cell lymphoma/clonal infiltrates in the bone marrow.

    Science.gov (United States)

    Hussein, Shafinaz; Gill, Kamraan; Baer, Lea N; Hoehn, Daniela; Mansukhani, Mahesh; Jobanputra, Vaidehi; Bhagat, Govind; Alobeid, Bachir

    2015-03-01

    Composite plasma cell neoplasm (PCN) and low grade B-cell lymphoma (B-NHL) in the bone marrow are uncommon and raise the differential diagnosis of B-NHL with plasmacytic differentiation and PCN with lymphoplasmacytic morphology. This can be a challenging differential diagnosis, and the distinctions are important because of differences in management. We report five cases of composite PCN with B-NHL or clonal B-cell infiltrates involving the bone marrow. By using multiple different diagnostic modalities, including immunophenotyping by flow cytometry and immunohistochemistry, cytogenetic analysis and IGH gene rearrangement studies by polymerase chain reaction, we were able to distinguish two distinct clonally unrelated neoplasms in all cases. We describe the utility and pitfalls of these different diagnostic modalities. Flow cytometric analysis with a panel of antibodies that includes CD19, CD56, CD138, CD45 and other aberrant markers commonly expressed by PCN will allow identification of clonally unrelated PCN and B-NHL in a composite neoplasm, and distinguish them from B-NHL with plasmacytic differentiation and PCN with lymphoplasmacytic morphology. Cytogenetic and molecular analyses can give false-negative or false-positive results. In summary, a multimodal approach utilizing these different tools, including clinical data, should be used to arrive at the correct diagnosis.

  8. Early detection of severe sepsis in the emergency room: diagnostic value of plasma C-reactive protein, procalcitonin, and interleukin-6.

    Science.gov (United States)

    Uusitalo-Seppälä, Raija; Koskinen, Pertti; Leino, Aila; Peuravuori, Heikki; Vahlberg, Tero; Rintala, Esa M

    2011-12-01

    To determine the diagnostic values of plasma C-reactive protein (CRP), procalcitonin (PCT), and interleukin-6 (IL-6) using an electrochemiluminescence immunoassay (ECLIA) method (Roche Diagnostics GmbH, Mannheim, Germany) to identify severe sepsis in an emergency room (ER) setting. This was a single-centre prospective follow-up study of 539 consecutive adult patients admitted to the ER with suspected infection. Blood samples were taken concurrently with blood cultures at admission. Patients were divided into 5 groups on the basis of systemic inflammatory response syndrome (SIRS) criteria, documentation of bacterial infection, and organ dysfunction. Fifty-nine patients with no SIRS or bacterial infection, 68 patients with bacterial infection but no SIRS, 54 patients with SIRS but no bacterial infection, 309 patients with sepsis (SIRS and bacterial infection), and 49 patients with severe sepsis (sepsis and organ failure) were evaluated. In a logistic regression model, the odds ratio (OR) for PCT was 1.58 (95% confidence interval (CI) 1.37-1.82, p sepsis, but the difference in AUC was not significant between PCT and IL-6. In multivariate logistic regression analysis, after adjusting for confounders, PCT and IL-6 remained significant independent predictors of severe sepsis. PCT and IL-6 proved superior to CRP in detecting patients with severe sepsis. The findings thus support the use of either PCT or IL-6 as an early tool to diagnose severe sepsis. The automatic ECLIA method allows even night-shift measurements.

  9. C/NOFS satellite observations of equatorial ionospheric plasma structures supported by multiple ground-based diagnostics in October 2008

    Science.gov (United States)

    Nishioka, M.; Basu, Su.; Basu, S.; Valladares, C. E.; Sheehan, R. E.; Roddy, P. A.; Groves, K. M.

    2011-10-01

    In early October 2008, the C/NOFS satellite orbited near the magnetic equator at its perigee altitude of ˜400 km at dusk in the Peruvian sector. This provided an ideal opportunity for a comparison, under the current very low solar flux condition, of equatorial ionospheric disturbances observed with the Communication/Navigation Outage Forecasting System (C/NOFS) in situ measurements and ground-based observations available near Jicamarca Observatory. The primary objective was the comparison of plasma density disturbances measured by a Planar Langmuir Probe (PLP) instrument on the C/NOFS satellite with VHF scintillation activity at Ancon near Jicamarca for this period. Here we discuss in detail two extreme cases: one in which severe in situ disturbances were accompanied by mild scintillation on a particular day, namely, 10 October while there was little in situ disturbance with strong scintillation on 5 October. This apparent contradiction was diagnosed further by a latitudinal ground-based GPS network at Peruvian longitudes, a Digisonde, and the incoherent scatter radar (ISR) at Jicamarca. The crucial distinction was provided by the behavior of the equatorial ionization anomaly (EIA). The EIA was well-developed on the day having severe in situ disturbances (10 Oct). This led to lower equatorial plasma density and total electron content (TEC) at the equator and consequently reduced the scintillations detected at Ancon. On the other hand, on the day with severe scintillations (5 Oct), the EIA was not so well developed as on 10 October, leading to relatively higher equatorial plasma density and TEC. Consequently the severe scintillations at Ancon were likely caused by ionospheric structure located below the altitude of C/NOFS. The NRL SAMI2 model was utilized to gain a greater understanding of the role of neutral winds and electric fields in reproducing the TEC as a function of latitude for both classes of irregularities. Spectral studies with high resolution in situ

  10. Measurements of transition probabilities for spin-changing lines of atomic ions used in diagnostics of astrophysical plasmas

    Science.gov (United States)

    Smith, P. L.; Johnson, B. C.; Kwong, H. S.; Parkinson, W. H.; Knight, R. D.

    1984-01-01

    The intensities of ultraviolet, spin-changing, 'intersystem' lines of low-Z atomic ions are frequently used in determinations of electron densities and temperatures in astrophysical plasmas as well as in measurements of element abundances in the interstellar gas. The transition probabilities (A-values) of these lines, which are about five orders of magnitude weaker than allowed lines, have not been measured heretofore and various calculations produce A-values for these lines that differ by as much as 50 percent A radio-frequency ion trap has been used for the first measurements of transition probabilities for intersystem lines seen in astronomical spectra. The measurement procedure is discussed and results for Si III, O III, N II, and C III are reviewed and compared to calculated values. Discrepancies exist; these indicate that some of the calculated A-values may be less reliable than has been beleived and that revisions to the electron densities determined for some astrophysical plasmas may be required.

  11. Diagnostics of plasma in the ionospheric D-region: detection and study of different ionospheric disturbance types

    Science.gov (United States)

    Nina, Aleksandra; Čadež, Vladimir M.; Popović, Luka Č.; Srećković, Vladimir A.

    2017-07-01

    Here we discuss our recent investigations of the ionospheric plasma by using very low and low frequency (VLF/LF) radio waves. We give a review of how to detect different low ionospheric reactions (sudden ionospheric disturbances) to various terrestrial and extra-terrestrial events, show their classification according to intensity and time duration, and present some methods for their detections in time and frequency domains. Investigations of detection in time domain are carried out for intensive long-lasting perturbations induced by solar X-ray flares and for short-lasting perturbations caused by gamma ray bursts. We also analyze time variations of signals used in the low ionospheric monitoring after earthquake events. In addition, we describe a procedure for the detection of acoustic and gravity waves from the VLF/LF signal analysis in frequency domain. The research of the low ionospheric plasma is based on data collected by the VLF/LF receivers located in Belgrade, Serbia. Contribution to the Topical Issue "Physics of Ionized Gases (SPIG 2016)", edited by Goran Poparic, Bratislav Obradovic, Dragana Maric and Aleksandar Milosavljevic.

  12. Fourier-transform infrared spectroscopy coupled with a classification machine for the analysis of blood plasma or serum: a novel diagnostic approach for ovarian cancer.

    Science.gov (United States)

    Gajjar, Ketan; Trevisan, Júlio; Owens, Gemma; Keating, Patrick J; Wood, Nicholas J; Stringfellow, Helen F; Martin-Hirsch, Pierre L; Martin, Francis L

    2013-07-21

    Currently available screening tests do not deliver the required sensitivity and specificity for accurate diagnosis of ovarian or endometrial cancer. Infrared (IR) spectroscopy of blood plasma or serum is a rapid, versatile, and relatively non-invasive approach which could characterize biomolecular alterations due to cancer and has potential to be utilized as a screening or diagnostic tool. In the past, no such approach has been investigated for its applicability in screening and/or diagnosis of gynaecological cancers. We set out to determine whether attenuated total reflection Fourier-transform IR (ATR-FTIR) spectroscopy coupled with a proposed classification machine could be applied to IR spectra obtained from plasma and serum for accurate class prediction (cancer vs. normal). Plasma and serum samples were obtained from ovarian cancer cases (n = 30), endometrial cancer cases (n = 30) and non-cancer controls (n = 30), and subjected to ATR-FTIR spectroscopy. Four derived datasets were processed to estimate the real-world diagnosis of ovarian and endometrial cancer. Classification results for ovarian cancer were remarkable (up to 96.7%), whereas endometrial cancer was classified with a relatively high accuracy (up to 81.7%). The results from different combinations of feature extraction and classification methods, and also classifier ensembles, were compared. No single classification system performed best for all different datasets. This demonstrates the need for a framework that can accommodate a diverse set of analytical methods in order to be adaptable to different datasets. This pilot study suggests that ATR-FTIR spectroscopy of blood is a robust tool for accurate diagnosis, and carries the potential to be utilized as a screening test for ovarian cancer in primary care settings. The proposed classification machine is a powerful tool which could be applied to classify the vibrational spectroscopy data of different biological systems (e.g., tissue, urine, saliva

  13. Coherence properties and diagnostics of betatron radiation emitted by an externally-injected electron beam propagating in a plasma channel

    Energy Technology Data Exchange (ETDEWEB)

    Paroli, B., E-mail: bruno.paroli@unimi.it [Dipartimento di Fisica, Universitá degli Studi di Milano and INFN Sezione di Milano, via G. Celoria, 16, 20133 Milano (Italy); Chiadroni, E.; Ferrario, M. [INFN-LNF, via E. Fermi, 00044 Frascati (Italy); Mostacci, A. [“La Sapienza” University, SBAI Department, via A. Scarpa 14, 00161 Rome (Italy); INFN-LNF, via E. Fermi, 00044 Frascati (Italy); Petrillo, V.; Potenza, M.A.C.; Rossi, A.R.; Serafini, L. [Dipartimento di Fisica, Universitá degli Studi di Milano and INFN Sezione di Milano, via G. Celoria, 16, 20133 Milano (Italy)

    2015-07-15

    A 3-dimensional time-domain simulation of X-ray produced by a laser wakefield accelerated electron beam was performed in order to know its properties like intensity, spectrum, divergence and coherence. Particular attention was paid to the coherence around the acceleration axis. The broad spectrum of betatron radiation (1–10 keV) leads to a short coherence length. Nevertheless we observe that under particular detection condition the spatial coherence has a characteristic enlargement. We give a simplified interpretation of this effect in terms of phase shift of the electric field on a virtual detector. Moreover we describe a near field scattering technique to characterize the betatron radiation. This diagnostics will be used to map the transverse spatio-temporal coherence of X-ray radiation in the laser wakefield accelerator under development at Frascati National Laboratories (LNF)

  14. Coherence properties and diagnostics of betatron radiation emitted by an externally-injected electron beam propagating in a plasma channel

    Science.gov (United States)

    Paroli, B.; Chiadroni, E.; Ferrario, M.; Mostacci, A.; Petrillo, V.; Potenza, M. A. C.; Rossi, A. R.; Serafini, L.

    2015-07-01

    A 3-dimensional time-domain simulation of X-ray produced by a laser wakefield accelerated electron beam was performed in order to know its properties like intensity, spectrum, divergence and coherence. Particular attention was paid to the coherence around the acceleration axis. The broad spectrum of betatron radiation (1-10 keV) leads to a short coherence length. Nevertheless we observe that under particular detection condition the spatial coherence has a characteristic enlargement. We give a simplified interpretation of this effect in terms of phase shift of the electric field on a virtual detector. Moreover we describe a near field scattering technique to characterize the betatron radiation. This diagnostics will be used to map the transverse spatio-temporal coherence of X-ray radiation in the laser wakefield accelerator under development at Frascati National Laboratories (LNF).

  15. Surface temperature measurement of the plasma facing components with the multi-spectral infrared thermography diagnostics in tokamaks

    Science.gov (United States)

    Zhang, C.; Gauthier, E.; Pocheau, C.; Balorin, C.; Pascal, J. Y.; Jouve, M.; Aumeunier, M. H.; Courtois, X.; Loarer, Th.; Houry, M.

    2017-03-01

    For the long-pulse high-confinement discharges in tokamaks, the equilibrium of plasma requires a contact with the first wall materials. The heat flux resulting from this interaction is of the order of 10 MW/m2 for steady state conditions and up to 20 MW/m2 for transient phases. The monitoring on surface temperatures of the plasma facing components (PFCs) is a major concern to ensure safe operation and to optimize performances of experimental operations on large fusion facilities. Furthermore, this measurement is also required to study the physics associated to the plasma material interactions and the heat flux deposition process. In tokamaks, infrared (IR) thermography systems are routinely used to monitor the surface temperature of the PFCs. This measurement requires an accurate knowledge of the surface emissivity. However, and particularly for metallic materials such as tungsten, this emissivity value can vary over a wide range with both the surface condition and the temperature itself, which makes instantaneous measurement challenging. In this context, the multi-spectral infrared method appears as a very promising alternative solution. Indeed, the system has the advantage to carry out a non-intrusive measurement on thermal radiation while evaluating surface temperature without requiring a mandatory surface emissivity measurement. In this paper, a conceptual design for the multi-spectral infrared thermography is proposed. The numerical study of the multi-channel system based on the Levenberg-Marquardt (LM) nonlinear curve fitting is applied. The numerical results presented in this paper demonstrate the design allows for measurements over a large temperature range with a relative error of less than 10%. Furthermore, laboratory experiments have been performed from 200 °C to 740 °C to confirm the feasibility for temperature measurements on stainless steel and tungsten. In these experiments, the unfolding results from the multi-channel detection provide good

  16. Diagnostic opportunities for evaluation of the exposure of dairy cows to the mycotoxins deoxynivalenol (DON) and zearalenone (ZEN): reliability of blood plasma, bile and follicular fluid as indicators.

    Science.gov (United States)

    Winkler, J; Kersten, S; Meyer, U; Stinshoff, H; Locher, L; Rehage, J; Wrenzycki, C; Engelhardt, U H; Dänicke, S

    2015-10-01

    To investigate the usefulness of follicular fluid (FF) in relation to blood plasma and bile as indicators of exposure of dairy cows to ZEN, DON and their metabolites, a dose-response study was performed with 30 dairy cows. The cows, 10 in each group (named CON; FUS-50, FUS-100), received a diet with three different concentrations of Fusarium toxin-contaminated maize. Thereby, the following dietary concentration were reached: CON (0.02 mg ZEN and 0.07 mg DON, per kg dry matter, DM), FUS-50 (0.33 mg ZEN and 2.62 mg DON, per kg DM) and FUS-100 (0.66 mg ZEN and 5.24 mg DON, per kg DM). ZEN, DON and de-epoxy-DON (de-DON) were detected in FF. Based on the linear regression between toxin concentration in plasma and FF, it seems that about 50% (m = 0.5) of ZEN present in plasma is present in FF while an increase of 1 ng/ml DON or de-DON in plasma is paralleled by an increase of 1.5 ng/ml DON or 1.1 ng/ml de-DON in FF. ZEN, DON and their metabolites, except zearalenone (ZAN), were also detected in bile. Contrary to DON and de-DON, ZEN and its metabolites were accumulated in bile so that the concentration of ZEN and metabolites was much higher than for DON and de-DON. The main compound was β-zearalenol (β-ZEL). The biliary ZEN, α-zearalenol (α-ZEL) and β-ZEL concentration correlated linearly with each other with an uncertainty of <15% (r(2) ≥ 0.86), whereas the ratio between ZEN: α-ZEL: β-ZEL was about 1.5:1:11. With the help of established linear relationship between toxin intake and toxin concentration, bile could be used as diagnostic indicator to assess the exposure of cows. Journal of Animal Physiology and Animal Nutrition © 2014 Blackwell Verlag GmbH.

  17. Influence of in-flight particle state diagnostics on properties of plasma sprayed YSZ-CeO2 nanocomposite coatings

    Directory of Open Access Journals (Sweden)

    S. Mantry

    2014-07-01

    Full Text Available This article describes the influence of controlling in-flight hot particle characteristics on properties of plasma sprayed nanostructured yttria stabilized zirconia (YSZ coatings. This article depicts dependence of adhesion strength of as-sprayed nanostructured YSZ coatings on particle temperature, velocity and size of the splat prior to impact on the metallic substrate. Particle temperature measurement is based on two-color pyrometry and particle velocities are measured from the length of the particle traces during known exposure times. The microstructure and adhesion strength of as-sprayed nano-YSZ coatings were studied. Field emission scanning electron microscopy results revealed that morphology of coating exhibits bimodal microstructure consisting of nano-zones reinforced in the matrix of fully melted particles. The coating adhesion strength is noticed to be greatly affected by the melting state of agglomerates. Maximum adhesion strength of 42.39 MPa has been experimentally found out by selecting optimum levels of particle temperature and velocity. The enhanced bond strength of nano-YSZ coating may be attributed to higher interfacial toughness due to cracks being interrupted by adherent nano-zones.

  18. Plasma diagnostics in two kinematic classes of CMEs observed by the Atmospheric Imaging Assembly onboard the Solar Dynamic Observatory

    Science.gov (United States)

    Chmielewska, E.; Tomczak, M.; Kołomański, S.; Mrozek, T.

    2016-11-01

    In order to study the dynamics and thermal properties of two kinematic classes of coronal mass ejections (CMEs) we analyzed two well-observed events in the early stage of their propagation, using multiwavelength observations from the Atmospheric Imaging Assembly (AIA) of the Solar Dynamic Observatory (SDO). For deriving differential emission measure (DEM) profiles and DEM maps of the basic structures of CMEs, we used two methods: the regularized inversion and the iterative forward-fitting approach. For the CME associated with a M2.0 class flare (CME-FL), we identified a hot, moving, blob-like feature which seems to be a candidate for a CME flux rope. Furthermore, an expanding system of loop and coronal dimming was clearly seen in AIA images. For the CME related to an eruptive prominence (CME-EP), we observed an eruptive plasmoid and a failed-eruption of cold plasma. However, we also recognized warm and hot moving signatures that revealed a multi-temperature nature of the eruptive prominence. Our main results are as follows: (a) An analysis of the examples of the two different kinematic classes of CMEs shows that despite the slight variations in the values of speeds and accelerations (CME-FL: v≈174 km s-1, a&ap350 m s-2; CME-EP: v≈135 km s-1, a≈160 m s-2) they present the same kinematic behavior; (b) in the field of view of the LASCO coronagraphs these two events have the similar, positive accelerations; (c) for both events we observed an impulsive acceleration phase (IAP); (d) the expanding structures seen in 171 Å, 193 Å, 211 Å in both events move faster than the hotter blobs; (e) the plasmoid core for the CME-FL is hot (8.0-15.8 MK); (f) the expanding blob and the hot structure in the prominence region for the CME-EP event have the similar temperature range (0.8-2.5 MK).

  19. Requirements for ITER diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Young, K.M.

    1991-01-01

    The development and design of plasma diagnostics for the International Thermonuclear Experimental Reactor (ITER) present a formidable challenge for experimental plasma physicists. The large plasma size, the high central density and temperature and the very high thermal wall loadings provide new challenges for present measurement techniques and lead to a search for new methods. But the physics and control requirements for the long burn phase of the discharge, combined with very limited access to the plasma, constrained by the requirement for radiation shielding of the coils and sharing of access ports with heating and current drive power, remote manipulation, fueling and turn blanket modules, make for very difficult design choices. An initial attempt at these choices has been made by an international team of diagnostic physicists, gathering together in a series of three workshops during the ITER Conceptual Design Activity. This paper is based on that report and provides a summary of its most important points. To provide a background against which to place the diagnostic requirements and design concepts, the ITER device, its most important plasma properties and the proposed experimental program will be described. The specifications for the measurement of the plasma parameters and the proposed diagnostics for these measurements will then be addressed, followed by some examples of the design concepts that have been proposed. As a result of these design studies, it was clear that there were many uncertainties associated with these concepts, particularly because of the nuclear radiation environment, so that a Research and Development Program for diagnostic hardware was established. It will also be briefly summarized.

  20. DIAGNOSTIC-VALUE OF PLASMA-LEVELS OF TUMOR-NECROSIS-FACTOR-ALPHA (TNF-ALPHA) AND INTERLEUKIN-6 (IL-6) IN NEWBORNS WITH SEPSIS

    NARCIS (Netherlands)

    DEBONT, ESJM; MARTENS, A; VANRAAN, J; SAMSON, G; FETTER, WPF; OKKEN, A; DELEIJ, LHFM; KIMPEN, J

    The aim of this study was to examine if TNF alpha and IL-6 plasma levels could be of value in diagnosing neonatal sepsis. Tumor necrosis factor alpha (TNF alpha) and interleukin-6 (IL-6) plasma levels were determined in 15 newborn infants with confirmed sepsis (group I), 18 with suspected sepsis

  1. Design and specifications of the diagnostics for the instrumented calorimeter of source for the production of ions of deuterium extracted from radio frequency plasma.

    Science.gov (United States)

    De Muri, M; Dalla Palma, M; Fasolo, D; Pasqualotto, R; Pomaro, N; Rizzolo, A; Serianni, G; Tollin, M

    2012-02-01

    In the development of the neutral beam injector for ITER experiment, the test facility SPIDER is going to be built. To measure the beam parameters, several diagnostics are used. One of them is the Short-Time Retractable Instrumented Kalorimeter Experiment (STRIKE) which measures beam uniformity, beamlet divergence, and stripping losses. This contribution gives an overview of the diagnostics dedicated to these measurements: thermal cameras, thermocouples, current sensors, and electrostatic sensors. The specifications of these diagnostics have been defined according to the results of electrostatic and thermal simulations. A failure modes and effects analysis has been performed during the design. Consequently the project of the STRIKE diagnostics has been optimized to reduce the possible failure risks.

  2. SIRT Method for Diagnostics of Inhomogeneous Dense DT Plasmas with Fast Protons%高能质子束探测稠密不均匀氘氚等离子体密度的SIRT算法

    Institute of Scientific and Technical Information of China (English)

    李雪梅; 沈百飞; 张晓梅; 王志文; 何燕和

    2011-01-01

    应用同时迭代重建算法(SIRT)重建不均匀稠密氘氚等离子体的密度分布.在二维等离子体密度重建的数值模拟中,探测稠密等离子体的高能质子束可以由强激光和等离子体相互作用产生,且质子束经过稠密等离子体后的能量损失是比较重要的.如果已知入射质子束和出射质子束的能量分布,可以在出射质子束能量测量的误差水平未知的情况下用SIRT算法重建等离子体的密度分布.结果显示,SIRT算法的精确度高于以L-曲线为准则的Tikhonov正则化方法,并可以在数据量不完全时重建密度分布.%Density reconstruction of inhomogeneous dense DT plasmas is studied with simultaneous iterative reconstruction technique (SIRT). In simulation of density diagnostics of a two-dimensional (2D) slice plasma, fast protons used for diagnostics can be generated with laser-plasma interaction and energy loss of fast protons going through plasmas is crucial. As original and final energies of protons are given, density reconstruction by SIRT method is done without noise level of final energies. Accuracy of the method is better than that of the Tikhonov regularization method based on deviation principle of L-curve. In addition,the SIRT method is available with incomplete data.

  3. Optical diagnostics and mass spectrometry on the afterglow of an atmospheric pressure Ar/O$_2$ radiofrequency plasma used for polymer surface treatment

    CERN Document Server

    Duluard, Corinne Y; Hubert, Julie; Reniers, François

    2016-01-01

    In the context of polymer surface treatment, the afterglow of an atmospheric pressure Ar/O$_2$ radiofrequency plasma is characterized by optical emission spectroscopy, laser induced fluorescence and mass spectrometry. The influence of the O$_2$ gas flow rate and the source power on the plasma properties (gas temperature, Ar excitation temperature, relative concentrations of O atoms and OH radicals) are evaluated. We show that for plasma torch-to-substrate distances lower than 6 mm, the afterglow creates a protective atmosphere, thus the plasma gas composition interacting with the substrate is well controlled. For higher distances, the influence of ambient air can no longer be neglected and gradients in Ar, O$_2$ and N$_2$ concentrations are measured as a function of axial and vertical position.

  4. International Workshop on Diagnostics for ITER

    CERN Document Server

    Gorini, Giuseppe; Sindoni, Elio

    1996-01-01

    This book of proceedings collects the papers presented at the Workshop on Diagnostics for ITER, held at Villa Monastero, Varenna (Italy), from August 28 to September 1, 1995. The Workshop was organised by the International School of Plasma Physics "Piero Caldirola. " Established in 1971, the ISPP has organised over fifty advanced courses and workshops on topics mainly related to plasma physics. In particular, courses and workshops on plasma diagnostics (previously held in 1975, 1978, 1982, 1986, and 1991) can be considered milestones in the history of this institution. Looking back at the proceedings of the previous meetings in Varenna, one can appreciate the rapid progress in the field of plasma diagnostics over the past 20 years. The 1995 workshop was co-organised by the Istituto di Fisica del Plasma of the National Research Council (CNR). In contrast to previous Varenna meetings on diagnostics, which have covered diagnostics in present-day tokamaks and which have had a substantial tutorial component, the 1...

  5. Calculation of fully relativistic cross sections for electron excitation of cesium atom and its application to the diagnostics of hydrogen-cesium plasma

    Science.gov (United States)

    Priti; Dipti; Gangwar, R. K.; Srivastava, R.

    2017-01-01

    Electron impact excitation cross-sections and rate coefficients have been calculated using fully relativistic distorted wave theory for several fine-structure transitions from the ground as well as excited states of cesium atom in the wide range of incident electron energy. These processes play dominant role in low pressure hydrogen-cesium plasma, which is relevant to the negative ion based neutral beam injectors for the ITER project. As an application, the calculated detailed cross-sections are used to construct a reliable collisional radiative (CR) model to characterize the hydrogen-cesium plasma. Other processes such as radiative population transfer, electron impact ionization and mutual neutralization of Cs+ ion with negative hydrogen ion along with their reverse processes are also taken into account. The calculated cross-sections and the extracted plasma parameters from the present model are compared with the available experimental and theoretical results.

  6. Electrical and spectroscopic diagnostics of a single-stage plasma-catalysis system: effect of packing with TiO2

    Science.gov (United States)

    Tu, Xin; Gallon, Helen J.; Whitehead, J. Christopher

    2011-12-01

    The influence of adding TiO2 on the electrical and spectroscopic characteristics of a N2 dielectric barrier discharge (DBD) has been investigated in a single-stage plasma-catalysis system. The introduction of the catalyst into the electrode gap leads to a transition in the discharge behaviour. The presence of the TiO2 pellets in the discharge significantly increases the vibrational temperature of N2 in the DBD, which suggests that the interaction of plasma and catalyst has a strong effect on the electron energy distribution function in the discharge with an increase in electron density in the high-energy tail of the distribution function.

  7. Electric-probe Diagnostics for Plasma Configuration of Large-scale Magnetically Dispersed Arc Plasma%大尺度磁分散电弧等离子体位形的静电探针诊断

    Institute of Scientific and Technical Information of China (English)

    查俊; 焦凌云; 白冰; 王城; 夏维东

    2013-01-01

    磁旋转电弧可以产生大面积均匀等离子体:磁分散电弧等离子体.利用快速移动水冷静电探针对大气压氩弧磁分散电弧等离子体进行了诊断,得到发生器弧室内的电子温度分布、电弧位形以及等离子体波动等信息.诊断结果表明:等离子体弧柱区呈圆盘状,并在轴向有较大扩张,弧柱区下游等离子体波动较大,为等离子体云与冷气团混合所致.将探针诊断结果与采用热力学平衡模型的数值计算结果比较,发现2者具有相似的等离子体位形,但实验测量得到的电子温度更高,等离子体分布范围更广.分析认为,这种差异可能是等离子体偏离局域热力学平衡和等离子体的不稳定性造成的.%Magnetically rotating arc can induce large-scale magnetically dispersed arc plasma.Using a fast-moving water-cooling electric probe,we diagnosed large-scale dispersed arc plasma in argon at atmospheric pressure,and obtained its electron temperature profile,arc plasma configuration and plasma fluctuation.It is shown that the arc column exhibits a disk configuration and expands in axial direction.In the meantime,the erratic fluctuation increases in the plasma downstream,which may be a result of the cold air entrainment in the plasma cloud.There is a good comparability in plasma configuration between the measurements and the simulations by local-thermedynamicequilibrium magneto-hydrodynamic model,while the measurements have relatively higher electron temperature and larger plasma volume phenomenon.Further analysis indicates that the difference may be caused by deviation from thermal equilibrium of plasma and instability of plasma.

  8. Nonthermal plasma chemistry and physics

    CERN Document Server

    Meichsner, Jurgen; Schneider, Ralf; Wagner, Hans-Erich

    2013-01-01

    In addition to introducing the basics of plasma physics, Nonthermal Plasma Chemistry and Physics is a comprehensive presentation of recent developments in the rapidly growing field of nonthermal plasma chemistry. The book offers a detailed discussion of the fundamentals of plasma chemical reactions and modeling, nonthermal plasma sources, relevant diagnostic techniques, and selected applications.Elucidating interconnections and trends, the book focuses on basic principles and illustrations across a broad field of applications. Expert contributors address environmental aspects of plasma chemist

  9. Diagnostic of the self-healing of metallized polypropylene film by modeling of the broadening emission lines of aluminum emitted by plasma discharge

    Science.gov (United States)

    Tortai, J.-H.; Bonifaci, N.; Denat, A.; Trassy, C.

    2005-03-01

    Metallized-film capacitors have the property, even under high continuous voltage, to self-heal i.e., to clear a defect in the dielectric. The self-healing process is a consequence of a transient arc discharge. It has been previously shown that during the discharge, due to Joule effect, the metal is vaporized until the arc extinguishes. The discharge duration has been found to be inversely proportional to the mechanical pressure applied on the layers of metallized films making up a capacitor. The aim of this study is to understand the physical processes involved in this spontaneous extinction of the arc discharge. Emission spectroscopy has been used to provide information about the physical properties (temperatures, electronic and neutral particles densities, etc.) of the plasma induces by a self-healing. An analysis, based on the broadenings and shifts of Al atomic lines, of the experimental light spectra obtained has shown that the self-healing process leads to the generation, from the vaporized metal, of a high-density and relatively weakly ionized aluminum plasma. The plasma density increases with the pressure applied on the film layers and, consequently, the density power needed to extend the plasma zone increases as well and the arc discharge goes out faster as experimentally observed.

  10. Total levels of tissue inhibitor of metalloproteinases 1 in plasma yield high diagnostic sensitivity and specificity in patients with colon cancer

    DEFF Research Database (Denmark)

    Holten-Andersen, Mads N; Christensen, Ib Jarle; Nielsen, Hans Jørgen;

    2002-01-01

    PURPOSE: The purpose of this study was to measure total levels of tissue inhibitor of metalloproteinases (TIMP-1) by ELISA in plasma from blood donors, patients with inflammatory bowel disease (IBD), and patients with cancer and to correlate the results to patient diagnosis. EXPERIMENTAL DESIGN: ...

  11. Total levels of tissue inhibitor of metalloproteinases 1 in plasma yield high diagnostic sensitivity and specificity in patients with colon cancer

    DEFF Research Database (Denmark)

    Holten-Andersen, Mads N; Christensen, Ib Jarle; Nielsen, Hans Jørgen;

    2002-01-01

    PURPOSE: The purpose of this study was to measure total levels of tissue inhibitor of metalloproteinases (TIMP-1) by ELISA in plasma from blood donors, patients with inflammatory bowel disease (IBD), and patients with cancer and to correlate the results to patient diagnosis. EXPERIMENTAL DESIGN...

  12. Rhodococcus equi pneumonia in foals: an assessment of the early diagnostic value of serum amyloid A and plasma fibrinogen concentrations in equine clinical practice.

    Science.gov (United States)

    Passamonti, F; Vardi, D M; Stefanetti, V; Marenzoni, M L; Prato, S; Cévese, P; Coletti, M; Pepe, M; Casagrande Proietti, P; Olea-Popelka, F

    2015-02-01

    Early diagnosis and prevention of Rhodococcus equi pneumonia in foals represent important goals for equine clinicians. Recent protocols for diagnosis and treatment of Rhodococcosis in foals typically rely on a multimodal approach based on sonographic evidence suggestive of pyogranulomas, sonographic abscess scores and laboratory findings including plasma fibrinogen concentrations, blood biochemistry testing and platelet and leukocyte counts. The aim of this study was to assess the utility of weekly testing of serum amyloid A (SAA) and plasma fibrinogen concentrations in foals to achieve early diagnosis of R. equi pneumonia prior to the onset of clinical signs. This testing was used to simulate a clinically practical screening procedure and compared with thoracic ultrasonography performed in parallel. The present study suggests that SAA does not represent a reliable early marker of Rhodococcosis when plasma concentrations are tested weekly. However, when clinical signs of R. equi pneumonia are present, SAA concentrations may allow clinicians to obtain 'real-time' indications concerning both the progress of infection and the effectiveness of therapy. This study raises the possibility that plasma fibrinogen monitoring starting at 1 week of age and repeated on a weekly basis, could serve as a screening test allowing clinicians to identify foals as suspected of R. equi infection. Future investigations regarding both physiological plasma fibrinogen concentrations in foals as well as fibrinogen kinetics in foals affected with R. equi pneumonia, including the establishment of appropriate reference intervals for the test method employed in this study, will be necessary in order to clarify this possibility. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. ORION laser target diagnostics.

    Science.gov (United States)

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  14. ORION laser target diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Bentley, C. D.; Edwards, R. D.; Andrew, J. E.; James, S. F.; Gardner, M. D.; Comley, A. J.; Vaughan, K.; Horsfield, C. J.; Rubery, M. S.; Rothman, S. D.; Daykin, S.; Masoero, S. J.; Palmer, J. B.; Meadowcroft, A. L.; Williams, B. M.; Gumbrell, E. T.; Fyrth, J. D.; Brown, C. R. D.; Hill, M. P.; Oades, K. [Plasma Physics Department, Atomic Weapons Establishment, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom); and others

    2012-10-15

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  15. Cleaved forms of the urokinase plasminogen activator receptor in plasma have diagnostic potential and predict postoperative survival in patients with ovarian cancer

    DEFF Research Database (Denmark)

    Henic, E.; Borgfeldt, C.; Christensen, I.J.;

    2008-01-01

    -FIA 3 measuring the liberated uPAR(I). Tumors were classified as benign (n = 211), borderline (possibly malignant; n = 30), and well (n = 19), moderately (n = 15), and poorly (n = 60) differentiated malignant. RESULTS: All uPAR forms as well as CA125 were statistically significant in univariate analysis...... (95% CI), 0.90-0.98] as well as borderline and benign tumors (AUC, 0.78; 95% CI, 0.67-0.89). All suPAR forms were markers for poor prognosis in univariate analyses, and high preoperative plasma level of uPAR(I) is an independent predictor of poor prognosis (hazard ratio, 1.84; 95% CI, 1.15-2.95; P = 0.......011) in multivariate analyses including age and CA125. CONCLUSIONS: High concentration of plasma uPAR(I) is an independent preoperative marker of poor prognosis in patients with ovarian cancer. The combination of plasma suPAR(I-III) + suPAR(II-III) and CA125 discriminates between malignant and benign tumors...

  16. Spectroscopic diagnostics of low-pressure inductively coupled Kr plasma using a collisional-radiative model with fully relativistic cross sections

    Science.gov (United States)

    Gangwar, Reetesh K.; Dipti; Srivastava, Rajesh; Stafford, Luc

    2016-06-01

    A collisional-radiative (C-R) model for krypton plasma using fully relativistic distorted-wave cross sections for electron excitations was developed. The model was applied to the characterization of inductively coupled Kr plasma with cylindrical geometry over the pressure regime 1-50 mTorr. Radially averaged emission intensities from transitions of Kr (4p55p  →  4p55s) in the range 500-900 nm were recorded at 17 cm from the planar RF-driven coil, with the plasma operated in the inductive regime (H mode). The measured emission intensities were then fitted by varying the electron density, n e, and electron temperature, T e, in the C-R model. At both low and high pressures, variations of the electron density by over two orders of magnitude had only a minor role on the relative emission intensities. On the other hand, T e values deduced from the comparison between experiment and model decreased from 6.7 to 2.6 eV as pressure increased from 1 to 50 mTorr. These results are found to be in good agreement with the effective electron temperature determined from Langmuir probe measurements and the predictions of a model based on the particle balance equation of charged particles.

  17. Development of a polarization resolved spectroscopic diagnostic for measurements of the magnetic field in the Caltech coaxial magnetized plasma jet experiment

    Science.gov (United States)

    Shikama, Taiichi; Bellan, Paul M.

    2011-11-01

    Measurements of the magnetic field strength in current-carrying magnetically confined plasmas are necessary for understanding the underlying physics governing the dynamical behavior. Such a measurement would be particularly useful in the Caltech coaxial magnetized plasma gun, an experiment used for fundamental studies relevant to spheromak formation, astrophysical jet formation/propagation, solar coronal physics, and the general behavior of twisted magnetic flux tubes that intercept a boundary. In order to measure the field strength in the Caltech experiment, a non-perturbing spectroscopic method is being implemented to observe the Zeeman splitting in the emission spectra. The method is based on polarization-resolving spectroscopy of the Zeeman-split σ components, a technique previously used in both solar and laboratory plasmas. We have designed and constructed an optical system that can simultaneously detect left- and right-circularly polarized emission with both high throughput and small extinction ratio. The system will be used on the 489.5 nm NII line, chosen because of its simple Zeeman structure and minimal Stark broadening.

  18. A Particle X-ray Temporal Diagnostic (PXTD) for studies of kinetic, multi-ion effects, and ion-electron equilibration rates in Inertial Confinement Fusion plasmas at OMEGA (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Sio, H. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Frenje, J. A. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Katz, J. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA; Stoeckl, C. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA; Weiner, D. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA; Bedzyk, M. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA; Glebov, V. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA; Sorce, C. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA; Gatu Johnson, M. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Rinderknecht, H. G. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Zylstra, A. B. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; Sangster, T. C. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA; Regan, S. P. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA; Kwan, T. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; Le, A. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; Simakov, A. N. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; Taitano, W. T. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; Chacòn, L. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; Keenan, B. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; Shah, R. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; Sutcliffe, G. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Petrasso, R. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA

    2016-09-14

    A Particle X-ray Temporal Diagnostic (PXTD) has been implemented on OMEGA for simultaneous time-resolved measurements of several nuclear products as well as the x-ray continuum produced in High Energy Density Plasmas and Inertial Confinement Fusion implosions. The PXTD removes systematic timing uncertainties typically introduced by using multiple instruments, and it has been used to measure DD, DT, D3He, and T3He reaction histories and the emission history of the x-ray core continuum with relative timing uncertainties within ±10-20 ps. This enables, for the first time, accurate and simultaneous measurements of the x-ray emission histories, nuclear reaction histories, their time differences, and measurements of Ti(t) and Te(t) from which an assessment of multiple-ion-fluid effects, kinetic effects during the shock-burn phase, and ion-electron equilibration rates can be made.

  19. A Particle X-ray Temporal Diagnostic (PXTD) for studies of kinetic, multi-ion effects, and ion-electron equilibration rates in Inertial Confinement Fusion plasmas at OMEGA (invited)

    Science.gov (United States)

    Sio, H.; Frenje, J. A.; Katz, J.; Stoeckl, C.; Weiner, D.; Bedzyk, M.; Glebov, V.; Sorce, C.; Gatu Johnson, M.; Rinderknecht, H. G.; Zylstra, A. B.; Sangster, T. C.; Regan, S. P.; Kwan, T.; Le, A.; Simakov, A. N.; Taitano, W. T.; Chacòn, L.; Keenan, B.; Shah, R.; Sutcliffe, G.; Petrasso, R. D.

    2016-11-01

    A Particle X-ray Temporal Diagnostic (PXTD) has been implemented on OMEGA for simultaneous time-resolved measurements of several nuclear products as well as the x-ray continuum produced in High Energy Density Plasmas and Inertial Confinement Fusion implosions. The PXTD removes systematic timing uncertainties typically introduced by using multiple instruments, and it has been used to measure DD, DT, D3He, and T3He reaction histories and the emission history of the x-ray core continuum with relative timing uncertainties within ±10-20 ps. This enables, for the first time, accurate and simultaneous measurements of the x-ray emission histories, nuclear reaction histories, their time differences, and measurements of Ti(t) and Te(t) from which an assessment of multiple-ion-fluid effects, kinetic effects during the shock-burn phase, and ion-electron equilibration rates can be made.

  20. Improving the screening of blood donors with syphilis rapid diagnostic test (RDT) and rapid plasma reagin (RPR) in low- and middle-income countries (LMIC)

    DEFF Research Database (Denmark)

    Sarkodie, F.; Hassall, O.; Owusu-Dabo, E.

    2017-01-01

    BACKGROUND: Syphilis testing conventionally relies on a combination of non-treponemal and treponemal tests. The primary objective of this study was to describe the positive predictive value (PPV) of a screening algorithm in a combination of a treponemal rapid diagnostic test (RDT) and rapid plasm...... of blood donors by combining syphilis RDT and RPR with relatively good PPV may provide a reasonable technology for LMIC that has a limited capacity for testing and can contribute to the improvement of blood safety with a minimal loss of donors....

  1. Diagnostics of Rovibrational Distribution of H2 in Low Temperature Plasmas by Fulcher-α band Spectroscopy - on the Reaction Rates and Transition Probabilities

    Institute of Scientific and Technical Information of China (English)

    Xiao Bingjia; Shinichiro Kado; Shin Kajita; Daisuge Yamasaki; Satoru Tanaka

    2005-01-01

    A novel fitting procedure is proposed for a better determination of H2 rovibrational distribution from the Fulcher-a band spectroscopy. We have recalculated the transition probabilities and the results show that they deviate from Franck-Condon approximation especially for the non-diagonal transitions. We also calculated the complete sets of vibrationally resolved crosssections for electron impact d3∏u- X3∑g transition based on the semi-classical Gryzinski theory.An example of experimental study confirms that current approach provides a tool for a better diagnostics of H2 rovibrational distribution in electronic ground state.

  2. Development of thin foil Faraday collector as a lost alpha particle diagnostic for high yield D-T tokamak fusion plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Van Belle, P.; Jarvis, O.N.; Sadler, G.J. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Cecil, F.E. [Colorado School of Mines, Golden, CO (United States)

    1994-07-01

    Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.

  3. Diagnostics of the plasma parameters based on the K X-ray line positions for various 4d and 4f metals

    Directory of Open Access Journals (Sweden)

    Szymańska Ewa

    2016-12-01

    Full Text Available This paper shows the theoretical predictions of the outer-shell ionization effect on the positions of Kα1,2, Kβ1,3, and K β2 X-ray lines for some 4d-transition metals (molybdenum and palladium and 4f rare-earth elements (dysprosium and ytterbium. The ionization energy shifts have been evaluated using the multiconfiguration Dirac-Fock method, containing Breit interaction and quantum electrodynamic (QED corrections. The presented results are important for obtaining the information about some parameters of plasma generated by different sources, especially by pulsed power machine and short-pulse lasers.

  4. Maternal plasma levels of cell-free β-HCG mRNA as a prenatal diagnostic indicator of placenta accrete.

    Science.gov (United States)

    Zhou, J; Li, J; Yan, P; Ye, Y H; Peng, W; Wang, S; Wang, X Tong

    2014-09-01

    Several biomarkers, including maternal serum creatinine kinase and α-fetoprotein, have been described as potential tools for the diagnosis of placental abnormalities. This study aimed to determine whether maternal plasma mRNA levels of the β subunit of human chorionic gonadotropin (β-HCG) could predict placenta accreta prenatally. Sixty-eight singleton pregnant women with prior cesarean deliveries (CDs) were classified into three groups: normal placentation (35 women, control group); placenta previa alone (21 women, placenta previa group); and both placenta previa and placenta accreta (12 women, placenta previa/accreta group). Maternal plasma concentrations of cell-free β-HCG mRNA were measured by real-time reverse-transcription polymerase chain reaction and were expressed as multiples of the median (MoM). Cell-free β-HCG mRNA concentrations (MoM, range) were significantly higher in women with placenta accreta (3.65, 2.78-7.19) than in women with placenta previa (0.94, 0.00-2.97) or normal placentation (1.00, 0.00-2.69) (Steel-Dwass test, P placenta previa/accreta group, the concentration of cell-free β-HCG mRNA was significantly higher among women who underwent CDs with hysterectomy (4.41, 3.49-7.19) than among women whose CDs did not result in hysterectomy (3.20, 2.78-3.70) (Mann-Whitney U test, P = 0.012). An increased level of cell-free β-HCG mRNA in the maternal plasma of women with placenta accreta may arise from direct uteroplacental transfer of cell-free placental mRNA molecules. The concentration of cell-free β-HCG mRNA in maternal plasma may be applicable to the prenatal diagnosis of placenta accreta, especially to identify women with placenta accreta likely to require hysterectomy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Elements of plasma technology

    CERN Document Server

    Wong, Chiow San

    2016-01-01

    This book presents some fundamental aspects of plasma technology that are important for beginners interested to start research in the area of plasma technology . These include the properties of plasma, methods of plasma generation and basic plasma diagnostic techniques. It also discusses several low cost plasma devices, including pulsed plasma sources such as plasma focus, pulsed capillary discharge, vacuum spark and exploding wire; as well as low temperature plasmas such as glow discharge and dielectric barrier discharge which the authors believe may have potential applications in industry. The treatments are experimental rather than theoretical, although some theoretical background is provided where appropriate. The principles of operation of these devices are also reviewed and discussed.

  6. Diagnostic Value of Plasma Tumor Necrosis Factor-α Concentration for Chronic Urticaria%血浆TNF-α浓度对慢性荨麻疹的诊断价值

    Institute of Scientific and Technical Information of China (English)

    雷素珍

    2012-01-01

    Objective To investigate the changes of plasma necrosis factor-α concentration in patients with chronic urticaria and analyze its diagnostic value. Methods 86 patients with chronic urticaria and 86 healthy controls were enrolled in this study. Determining plasma tumor necrosis factor-α (TNF-α) concentration with ELISA. Statistical analysis was taken. Results Plasma TNF-α concentration was significantly higher in patients than those of healthy controls (4.2 ±1.8 ng/ml vs 1.8 ±0.7)ng/ml, P2.8 ng/ml) that dignosed chronic urticaria with high sensitivity (83.1% ) and specificity (79. 1% ) respectively. Conclusion TNF-α may be involved in pathogenesis of chronic urticaria, and its concentration can effectively in diagnosis of chronic urticaria.%目的:揭示慢性荨麻疹患者血浆肿瘤坏死因子-α(TNF-α)浓度的变化,分析其对慢性荨麻疹的诊断价值.方法:选取门诊治疗的慢性荨麻疹患者及健康体检者各86例,ELISA检测血浆TNF-α浓度,对数据进行统计分析.结果:慢性荨麻疹患者血浆TNF-α浓度(4.2±1.8)ng/ml显著高于对照组(1.8±0.7)ng/ml(P2.8 ng/ml),对诊断慢性荨麻疹有较高的灵敏度(83.7%)和特异度(79.1%).结论:TNF-α可能参与慢性荨麻疹的发病机制,其浓度可有效诊断慢性荨麻疹.

  7. Thermal and electrostatic simulations of the diagnostic calorimeter for the source for production of ion of deuterium extracted from RF plasma beam.

    Science.gov (United States)

    Serianni, G; Dalla Palma, M; De Muri, M; Fasolo, D; Pasqualotto, R; Pomaro, N; Rizzolo, A; Tollin, M

    2012-02-01

    To study and optimise negative ion production for the ITER neutral beam injectors, a test facility is under construction in Padova with the aim of testing beam characteristics and to verify the source proper operation. The instrumented calorimeter STRIKE (short-time retractable instrumented kalorimeter experiment) is being developed to characterise the SPIDER (Source for Production of Ion of Deuterium Extracted from RF plasma) beam during short operations. The paper presents an investigation of the response of STRIKE measurement systems. It results that biasing is necessary to cope with the influence of secondary electrons on current measurements; moreover, despite the discretisation of the recorded thermal patterns introduced by the pixels of thermal cameras, a sufficient spatial resolution is expected.

  8. High performance diagnostics for Time-Of-Flight and X ray measurements in laser produced plasmas, based on fast diamond detectors

    Science.gov (United States)

    De Angelis, R.; Consoli, F.; Verona, C.; Di Giorgio, G.; Andreoli, P.; Cristofari, G.; Cipriani, M.; Ingenito, F.; Marinelli, M.; Verona-Rinati, G.

    2016-12-01

    The paper reports about the use of single-crystal Chemical Vapour Deposited (CVD) diamonds as radiation detectors in laser-matter interaction experiments on the ABC laser in ENEA - Frascati. The detectors have been designed and realized by University of Tor Vergata - Rome. The interdigital configuration and the new design of the bias-tee voltage supply units guarantee a fast time response. The detectors are sensitive to soft-X photons and to particles. A remarkable immunity to electromagnetic noise, associated with the laser-target interaction, makes them especially useful for the measurements of the time of flight of fast particles. A novel diamond assembly has been tested in plasmas generated by the ABC laser in the nanosecond regime at intensities I=1013÷ 14 W/cm2, where contributions from X rays, fast electrons and ions could be observed.

  9. ITER diagnostics ex-vessel engineering services

    Energy Technology Data Exchange (ETDEWEB)

    Arumugam, A.P., E-mail: arun.prakash@iter.org; Walker, C.I.; Andrew, P.; Barnsley, R.; Beltran, D.; Bertalot, L.; Dammann, A.; Direz, M.F.; Drevon, J.M.; Encheva, A.; Giacomin, T.; Hourtoule, J.; Kuehn, I.; Lanza, R.; Levesy, B.; Maquet, P.; Patel, K.M.; Patisson, L.; Pitcher, C.S.; Portales, M.; and others

    2013-10-15

    Highlights: • This paper describes about the ITER diagnostics ex-vessel engineering services. • It describes various diagnostics systems, its location and its environment. • Diagnostics interfaces with other services such as the buildings, HVAC, electrical services, cooling water, vacuum, liquid and gas distribution. • All the interfaces with these services are identified and defined. • Buildings services for diagnostics, such as penetrations, local shielding, embedment and temperature control are discussed. -- Abstract: Extensive diagnostics systems will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include measurements of temperature, density, impurity concentration, and particle and energy confinement times. ITER diagnostic systems extend from the center of the Tokamak to the various diagnostic areas, where they are controlled and acquired data is processed. This mainly includes the areas such as ports, port cells, gallery, diagnostics enclosures and cubicle areas. The diagnostics port plugs encloses the front end of the diagnostic systems and the diagnostics building houses the diagnostics equipment, instrumentation and control cubicles. There are several systems providing services to diagnostics. These mainly include ITER buildings, electrical power services, cooling water services, Heating Ventilation and Air Conditioning (HVAC), vacuum services, liquid and gas distribution services, cable engineering, de-tritiation systems, control cubicles, etc. Requirements of these service systems have to be defined, even though many of the diagnostics are at an early stage of development. It is a real challenge to define and to design diagnostics systems considering the constraints imposed by these service systems. This paper summarizes the provision of these services to the individual diagnostics and diagnostics areas

  10. Experimental and theoretical research in applied plasma physics

    Energy Technology Data Exchange (ETDEWEB)

    Porkolab, M.

    1992-01-01

    This report discusses research in the following areas: fusion theory and computations; theory of thermonuclear plasmas; user service center; high poloidal beta studies on PBX-M; fast ECE fluctuation diagnostic for balloning mode studies; x-ray imaging diagnostic; millimeter/submillimeter-wave fusion ion diagnostics; small scale turbulence and nonlinear dynamics in plasmas; plasma turbulence and transport; phase contrast interferometer diagnostic for long wavelength fluctuations in DIII-D; and charged and neutral fusion production for fusio plasmas.

  11. ITER diagnostic system: Vacuum interface

    Energy Technology Data Exchange (ETDEWEB)

    Patel, K.M., E-mail: Kaushal.Patel@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Drevon, J.M. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Encheva, A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Kashchuk, Y. [Institution “PROJECT CENTER ITER”, 1, Akademika Kurchatova pl., Moscow (Russian Federation); Maquet, Ph. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France)

    2013-10-15

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10{sup −7} Pa, irrespective of plasma operation, and a leak rate of less than 10{sup −10} Pa m{sup 3} s{sup −1}. In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions

  12. Increased IgG4-Positive Plasma Cells in Granulomatosis with Polyangiitis: A Diagnostic Pitfall of IgG4-Related Disease

    Directory of Open Access Journals (Sweden)

    Sing Yun Chang

    2012-01-01

    Full Text Available Granulomatosis with polyangiitis (Wegener’s (GPA may mimic IgG4-related disease (IgG4-RD on histologic examination of some biopsies, especially those from head and neck sites. IgG4 immunostain is often performed in this context for differential diagnosis with IgG4-RD. However, the prevalence of IgG4+ cells in GPA has not been explored. We examined the IgG4+ cells in 26 cases confirmed as GPA by a thorough clinical and pathologic assessment. Twenty-six biopsies consisted of 14 sinonasal/oral cavity/nasopharynx, 7 orbit/periorbital, 3 lung/pleura, 1 iliac fossa/kidney, and 1 dura specimens. Eight of 26 (31% biopsies revealed increased IgG4+ cells (>30/HPF and >40% in IgG4+/IgG+ ratio. The IgG4+ cells and IgG4+/IgG+ ratio ranged 37–137/hpf and 44–83%, respectively. Eight biopsies with increased IgG4+ cells were from sinonasal (n=4 or orbital/periorbital (n=4 sites. In conclusion, increased IgG4+ cells are not uncommonly seen in sinonasal or orbital/periorbital biopsies of GPA, which could pose as a diagnostic pitfall.

  13. Direct analysis of carbohydrates in animal plasma by ion chromatography coupled with mass spectrometry and pulsed amperometric detection for use as a non-invasive diagnostic tool.

    Science.gov (United States)

    Kotnik, Darja; Smidovnik, Andrej; Jazbec-Križman, Petra; Križman, Mitja; Prošek, Mirko

    2011-12-01

    The present paper demonstrates that electrochemical detection (ECD) coupled to ion chromatography and electrospray ionization tandem mass spectrometry (IC-ECD-ESI/MS/MS) can be used to rapidly estimate some indications of the health status of organisms. The lactulose to mannitol ratio (L/M) is used as a non-invasive assay to investigate small intestinal absorption pathways and mucosal integrity. In the present study, an evaluation of the negative effects of nonsteroidal anti-inflammatory drug meloxicam perorally administrated to a group of dogs was carried out by determining the lactulose/mannitol index using the IC-ECD-ESI/MS/MS hyphenated technique. According to the results of the study, meloxicam altered gastrointestinal permeability. Coenzyme Q(10) (CoQ(10)) was tested to determine if it could prevent meloxicam induced gastrointestinal damage and it was found that CoQ(10) could be an effective preventive treatment. Furthermore, plasma glucose concentration level was determined to be an indirect indicator of the oxidative state in the blood. To find out the beneficial effects of a double antioxidant combination (α-lipoic acid (ALA) and CoQ(10)) on the total glucose level in chickens, ALA and CoQ(10) were provided as food additives in factory farm raised chicken. The results of the pilot study indicate that the glucose level in the plasma of chickens group fed with CoQ(10) and ALA was significantly decreased compared to the control group. Ion chromatography (IC) utilizing pulsed amperometric detection (PAD) was compared to ion chromatography coupled with tandem mass spectrometry (MS/MS) as an analytical tool for monitoring the carbohydrate level in biological fluids. In electrochemical detection, the newly developed two-pulse waveform successfully withstands matrix effects in biological samples. Continuous on-line desalting of the high salt concentrations used as the eluent for carbohydrate separation from the anion-exchange column allows coupling of IC and MS

  14. The various assays for measuring activity states of factor VIIa in plasma and therapeutic products: Diagnostic value and analytical usefulness in various pathophysiological states.

    Science.gov (United States)

    Amiral, Jean; Dunois, Claire; Amiral, Cédric; Seghatchian, Jerard

    2016-12-29

    The key coagulation factor FVII, and its activated form FVIIa, present a major interest for their role at the initiation phase of blood coagulation, and because they can activate all blood coagulation cascade, through the extrinsic, but also the intrinsic pathway. Blood activation initiated through FVII is first presented, as it is understood nowadays. Measurement of FVII and FVIIa were of main interest for epidemiological studies, but FVIIa contribution to assay results was only deduced. The introduction of specific FVIIa assays, functional or immunoassays, allowed measuring directly FVIIa without any interference of non-activated FVII, or other coagulation factors or their activated forms. The various methods available, and their characteristics are presented, with a special focus on two assays developed by our group for FVIIa (a clotting one and a chromogenic one). The FVIIa clotting assay shows evident superiority for measuring its activity in plasma, in pathophysiological conditions. The normal range is products, or for following recoveries in treated patients, including hemophiliacs with inhibitors, patients with severe bleeding risk (liver diseases, surgery, trauma, …), and lastly for measurement of its activity in therapeutic products.

  15. Application and Analysis of the Isoelectronic Line Ratio Temperature Diagnostic in a Planar Ablating-Plasma Experiment at the National Ignition Facility

    Science.gov (United States)

    Epstein, R.; Rosenberg, M. J.; Solodov, A. A.; Myatt, J. F.; Regan, S. P.; Seka, W.; Hohenberger, M.; Barrios, M. A.; Moody, J. D.

    2015-11-01

    The Mn/Co isoelectronic emission-line ratio from a microdot source in planar CH foil targets was measured to infer the electron temperature (Te) in the ablating plasma during two-plasmon-decay experiments at the National Ignition Facility (NIF). We examine the systematic uncertainty in the Te estimate based on the temperature and density sensitivities of the line ratio in conjunction with plausible density constraints, and its contribution to the total Te estimate uncertainty. The potential advantages of alternative microdot elements (e.g., Ti/Cr and Sc/V) are considered. The microdot mass was selected to provide ample line strength while minimizing the effect of self-absorption on the line emission, which is of particular concern, given the narrow linewidths of mid- Z emitters at subcritical electron densities. Atomic line-formation theory and detailed atomic-radiative simulations show that the straight forward interpretation of the isoelectronic ratio solely in terms of its temperature independence remains valid with lines of moderate optical thickness (up to ~ 10) at line center. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.

  16. Study of an H{sub 2}/CH{sub 4} moderate pressure microwave plasma used for diamond deposition: modelling and IR tuneable diode laser diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Lombardi, G [Laboratoire d' Ingenierie des Materiaux et des Hautes Pressions, CNRS UPR 1311, Universite Paris 13, 99 av. J.B. Clement, 93430 Villetaneuse (France); Hassouni, K [Laboratoire d' Ingenierie des Materiaux et des Hautes Pressions, CNRS UPR 1311, Universite Paris 13, 99 av. J.B. Clement, 93430 Villetaneuse (France); Stancu, G D [INP-Greifswald, Friedrich-Ludwig-Jahn-Str. 19, 17489 Greifswald (Germany); Mechold, L [Laser Components GmbH, Werner-von-Siemens-Str. 15, 82140 Olching (Germany); Roepcke, J [INP-Greifswald, Friedrich-Ludwig-Jahn-Str. 19, 17489 Greifswald (Germany); Gicquel, A [Laboratoire d' Ingenierie des Materiaux et des Hautes Pressions, CNRS UPR 1311, Universite Paris 13, 99 av. J.B. Clement, 93430 Villetaneuse (France)

    2005-08-01

    Infra-red tuneable diode laser spectroscopy (IR TDLAS) has been used to detect and quantify the methyl radical and three stable carbon-containing species (CH{sub 4}, C{sub 2}H{sub 2} and C{sub 2}H{sub 6}) in a moderate pressure microwave (f = 2.45 GHz) bell-jar reactor used for diamond films deposition. A wide range of experimental conditions was investigated, with typical pressure/power required to perform diamond deposition, i.e. pressure from 2500 to 12 000 Pa and power from 600 W to 2 kW, which means gas temperatures ranging from 2200 to 3200 K, when the power density increases from 9 to 30 W cm{sup -3}. Since TDLAS is a line of sight averaged technique, the analysis of the experimental data required the use of a one-dimensional non-equilibrium transport model that provides species density and gas temperature variations along the optical beam. This model describes the plasma in terms of 28 species/131 reactions reactive flow. The thermal non-equilibrium is described by distinguishing a first energy mode for the electron and a second one for the heavy species. Parametric studies as a function of power density and methane percentage in the gas mixture are presented. The good agreement obtained between measurement and one-dimensional radial calculations allows a validation of the thermo-chemical model, which can be used as a tool to enlighten the chemistry in the spatially non-uniform H{sub 2}/CH{sub 4} microwave discharge used for diamond deposition. This is especially of interest for high power density discharge conditions that remain poorly understood.

  17. Astrovirus Diagnostics

    Science.gov (United States)

    Pérot, Philippe; Lecuit, Marc; Eloit, Marc

    2017-01-01

    Various methods exist to detect an astrovirus infection. Current methods include electron microscopy (EM), cell culture, immunoassays, polymerase chain reaction (PCR) and various other molecular approaches that can be applied in the context of diagnostic or in surveillance studies. With the advent of metagenomics, novel human astrovirus (HAstV) strains have been found in immunocompromised individuals in association with central nervous system (CNS) infections. This work reviews the past and current methods for astrovirus detection and their uses in both research laboratories and for medical diagnostic purposes. PMID:28085120

  18. Diagnostics for PLX-alpha

    Science.gov (United States)

    Gilmore, Mark; Hsu, Scott

    2015-11-01

    The goal of the Plasma Liner eXperiment PLX-alpha at Los Alamos National Laboratory is to establish the viability of creating a spherically imploding plasma liner for MIF and HED applications, using a spherical array of supersonic plasma jets launched by innovative contoured-gap coaxial plasma guns. PLX- α experiments will focus in particular on establishing the ram pressure and uniformity scalings of partial and fully spherical plasma liners. In order to characterize these parameters experimentally, a suite of diagnostics is planned, including multi-camera fast imaging, a 16-channel visible interferometer (upgraded from 8 channels) with reconfigurable, fiber-coupled front end, and visible and VUV high-resolution and survey spectroscopy. Tomographic reconstruction and data fusion techniques will be used in conjunction with interferometry, imaging, and synthetic diagnostics from modeling to characterize liner uniformity in 3D. Diagnostic and data analysis design, implementation, and status will be presented. Supported by the Advanced Research Projects Agency - Energy - U.S. Department of Energy.

  19. Imaging Techniques for Microwave Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Donne, T. [FOM-Institute for Plasma Physics Rijnhuizen, Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Luhmann Jr, N.C. [University of California, Davis, CA 95616 (United States); Park, H.K. [POSTECH, Pohang, Gyeongbuk 790-784 (Korea, Republic of); Tobias, B.

    2011-07-01

    Advances in microwave technology have made it possible to develop a new generation of microwave imaging diagnostics for measuring the parameters of magnetic fusion devices. The most prominent of these diagnostics is electron cyclotron emission imaging (ECE-I). After the first generation of ECE-I diagnostics utilized at the TEXT-U, RTP and TEXTOR tokamaks and the LHD stellarator, new systems have recently come into operation on ASDEX-UG and DIII-D, soon to be followed by a system on KSTAR. The DIII-D and KSTAR systems feature dual imaging arrays that observe different parts of the plasma. The ECE-I diagnostic yields two-dimensional movies of the electron temperature in the plasma and has given already new insights into the physics of sawtooth oscillations, tearing modes and edge localized modes. Microwave Imaging Reflectometry (MIR) is used on LHD to measure electron density fluctuations. A pilot MIR system has been tested at TEXTOR and, based on the promising results, a new system is now under design for KSTAR. The system at TEXTOR was used to measure the plasma rotation velocity. The system at KSTAR and also the one on LHD will be/are used for measuring the profile of the electron density fluctuations in the plasma. Other microwave imaging diagnostics are phase imaging interferometry, and imaging microwave scattering. The emphasis in this paper will be largely focused on ECE-I. First an overview of the advances in microwave technology are discussed, followed by a description of a typical ECE-I system along with some typical experimental results. Also the utilization of imaging techniques in other types of microwave diagnostics will be briefly reviewed. This document is composed of the slides of the presentation. (authors)

  20. 99mTc-HEPIDA hepatic clearance as a diagnostic tool: usefulness of plasma and hepatic clearance for assessment of hepatic parenchyma performance.

    Science.gov (United States)

    Frieske, Izabela; Surma, Marian J; Bieńkiewicz, Małgorzata; Białkowska-Warzecha, Jolanta; Liniecki, Julian; Kuydowicz, Jan; Kuśmierek, Jacek

    2003-01-01

    Plasma clearance of (99m)Tc-HEPIDA (Cl(Pl)) has been used for two decades for assessment of liver function in patients with diseases of this organ. A specific determination of (99m)Tc-HEPIDA liver clearance (Cl(Hp)) has been developed that provides more direct possibility to evaluate performance of liver parenchyma. Both tests have been studied in healthy volunteers of varying age (48 individuals) and in 83 patients with varying degree of liver damage. The liver damage has been evaluated on the basis of 5 biochemical tests (AspAT, ALAT, GGTP, bilirubine serum concentration, proteinogram) and a score system used for total impairment, which was calculated for each patient. Normal range of Cl(Pl) and Cl(Hp) was determined from a study on healthy individuals (volunteers). The results seem independent of age, but show sex differences. The following values (mean +/- SD) of Cl(Hp) were found in males and females of: (181 +/- 31) ml//min/1.73 m(2) and (158 +/- 22) ml/min/1.73m(2), and of Cl(Pl) were (224 +/- 33) ml/min/1.73 m(2) and (202 +/- 25) ml/min/1.73 m(2) respectively. Accepted lower boundaries of both quantities (mean -2SD) are 115 ml/min/1.73 m(2) and 150 ml/min/1.73 m(2) correspondingly. Negative correlation of individual values of both clearances in all patients with individual score of liver damage were highly significant and correlation coefficients obtained were higher for Cl(Hp) (r = -0.63) than those for Cl(Pl) (r= -0.56). Factorial analysis was performed with the intention of seeing which of the studied factors had the highest factor loading for parenchyma performance that was assumed as the common factor responsible for correlations. The highest value was obtained for hepatic clearance (Cl(Hp)) of (99m)Tc-HEPIDA. In conclusion this quantity seems highly promising as a clinically useful test for assessment of liver performance, both in screening for liver damage and for monitoring of organ conditions during therapy and follow-up of patients.

  1. Diagnostic Suite for the PLX- α Project

    Science.gov (United States)

    Yates, Kevin; Gilmore, Mark; Langendorf, Samuel; Dunn, John; Vaughan, Jacquelynne; Martinez, Ricardo; Hsu, Scott

    2016-10-01

    The Plasma Liner Experiment-ALPHA (PLX- α) at Los Alamos National Laboratory is demonstrating the viability and scalability of spherically imploding plasma liners as a compression driver for plasma-jet-driven magneto-inertial fusion (PJMIF). On PLX- α, plasma liners will be formed by merging up to 60 supersonic plasma jets. We are currently conducting conical-liner experiments ( π/2 solid angle with 6 and 7 plasma guns) to diagnose the jet-merging process and determine the values of post-merge Mach-number-degradation and liner uniformity. The diagnostic suite includes 12-chord interferometry, visible-light survey spectroscopy, high-resolution visible spectroscopy, single- and multi-frame intensified visible imaging, and schlieren imaging. The diagnostics suite and a comparison to synthetic data from 3D simulations on the 6- and 7-jet configurations will be presented. Supported by the ARPA-E ALPHA Program.

  2. Diagnostics for FIRE: A status report

    Science.gov (United States)

    Young, Kenneth M.

    2003-03-01

    The mission for the proposed fusion ignition research experiment (FIRE) device is to "attain, explore, understand and optimize fusion-dominated plasmas." Operation at Q⩾5, for 20 s with a fusion power output of ˜150 MW is the major goal. Attaining this mission sets demands for plasma measurement which are at least as comprehensive as on present tokamaks, with the additional capabilities needed for control of the plasma and for understanding the effects of the alpha-particles. Because of the planned operation in advanced tokamak scenarios, with steep transport barriers, the diagnostic instrumentation must be able to provide fine spatial and temporal resolution. It must also be able to withstand the impact of the intense neutron and gamma irradiation. There are practical engineering issues of minimizing radiation streaming while providing essential diagnostic access to the plasma. Many components will operate close to the first wall, e.g., ceramics and mineral insulated cable for magnetic diagnostics and mirrors for optical diagnostics; these components must be selected and mounted so that they will operate and survive in fluxes which require special material selection. The measurement requirements have been assessed so that the diagnostics for the FIRE device can be defined. Clearly, a better set of diagnostics of alpha-particles than that available for TFTR is essential, since the alpha-particles provide the dominant sources of heating and of instability-drive in the plasma.

  3. High power microwave diagnostic for the fusion energy experiment ITER

    DEFF Research Database (Denmark)

    Korsholm, Søren Bang; Leipold, Frank; Goncalves, B.

    2016-01-01

    Microwave diagnostics will play an increasingly important role in burning plasma fusion energy experiments like ITER and beyond. The Collective Thomson Scattering (CTS) diagnostic to be installed at ITER is an example of such a diagnostic with great potential in present and future experiments....... The ITER CTS diagnostic will inject a 1 MW 60 GHz gyrotron beam into the ITER plasma and observe the scattering off fluctuations in the plasma — to monitor the dynamics of the fast ions generated in the fusion reactions....

  4. Plasma diagnostics of the SIMPA Ecr ion source by X-ray spectroscopy, Collisions of H-like Neon ions with Argon clusters; Diagnostic du plasma de la source d'ions ECR SIMPA par spectroscopie X, Collision d'ions neon hydrogenoides avec des agregats d'argon

    Energy Technology Data Exchange (ETDEWEB)

    Adrouche, N

    2006-09-15

    The first part of this thesis is devoted to the SIMPA ECR ion source characterization, first, I explored the ion source's capacities on the point of view of extracted currents for three elements, argon, krypton and neon. By analyzing the Bremsstrahlung spectra, I determined the electronic temperature in the plasma and the electronic and ionic densities. In a second time, I recorded high resolution X-spectra of argon and krypton plasma's. By taking into account the principal mechanisms of production of a K hole in the ions inside the plasma, I determined the ionic densities of the high charge states of argon. Lastly, I highlighted a correlation between the ions charge states densities with the intensities of extracted currents. The second part of the thesis is devoted to Ne{sup 9+-} argon clusters collisions. First, I presented simple and effective theoretical models allowing to describe the phenomena occurring during a collision, from the point of view of the projectile. I carried out a simulation for a collision of an ion Ne{sup 9+} with an argon cluster of a given size, which has enabled us to know the energy levels populated during the electronic capture and to follow the number of electrons in each projectile shell. Lastly, I presented the first results of a collision between a Ne{sup 9+} beam and argon clusters. These results, have enabled me by using projectile X-ray spectroscopy during the ions-clusters collision, to evidence a strong clustering of targets atoms and to highlight an electronic multi-capture in the projectile ion excited states. (author)

  5. Plasma scattering of electromagnetic radiation

    CERN Document Server

    Sheffield, John

    1975-01-01

    Plasma Scattering of Electromagnetic Radiation covers the theory and experimental application of plasma scattering. The book discusses the basic properties of a plasma and of the interaction of radiation with a plasma; the relationship between the scattered power spectrum and the fluctuations in plasma density; and the incoherent scattering of low-temperature plasma. The text also describes the constraints and problems that arise in the application of scattering as a diagnostic technique; the characteristic performance of various dispersion elements, image dissectors, and detectors; and the ge

  6. First Wall and Operational Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Lasnier, C; Allen, S; Boedo, J; Groth, M; Brooks, N; McLean, A; LaBombard, B; Sharpe, J; Skinner, C; Whyte, D; Rudakov, D; West, W; Wong, C

    2006-06-19

    In this chapter we review numerous diagnostics capable of measurements at or near the first wall, many of which contribute information useful for safe operation of a tokamak. There are sections discussing infrared cameras, visible and VUV cameras, pressure gauges and RGAs, Langmuir probes, thermocouples, and erosion and deposition measurements by insertable probes and quartz microbalance. Also discussed are dust measurements by electrostatic detectors, laser scattering, visible and IR cameras, and manual collection of samples after machine opening. In each case the diagnostic is discussed with a view toward application to a burning plasma machine such as ITER.

  7. Thyroid diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Scriba, P.C.; Boerner, W.; Emrich, S.; Gutekunst, R.; Herrmann, J.; Horn, K.; Klett, M.; Krueskemper, H.L.; Pfannenstiel, P.; Pickardt, C.R.

    1985-03-01

    None of the in-vitro and in-vivo methods listed permits on unambiguous diagnosis when applied alone, owing to the fact that similar or even identical findings are obtained for various individual parameters in different thyroid diseases. Further, especially the in-vitro tests are also subject to extrathyroidal effects which may mask the typical findings. The limited and varying specificity and sensitivity of the tests applied, as well as the falsification of results caused by the patients' idiosyncracies and the methodology, make it necessary to interpret and evaluate the in-vivo and in-vitro findings only if the clinical situation (anamnesis and physical examination) is known. For maximum diagnostic quality of the tests, the initial probability of the assumed type of thyroid disease must be increased (formulation of the clinical problem). The concepts of exclusion diagnosis and identification must be distinguished as well as the diagnosis of functional disturbances on the one hand and of thyroid diseases on the other. Both of this requires a qualified, specific and detailed anamnesis and examination procedure, and the clinical examination remains the obligatory basis of clinical diagnostics. In case of inexplicable discrepancies between the clinical manifestations and the findings obtained with specific methods, or between the findings obtained with a specific method, the patient should be referred to an expert institution, or the expert institution should be consulted.

  8. Ultracold Neutral Plasmas

    CERN Document Server

    Killian, T C; Gupta, P; Laha, S; Martinez, Y N; Mickelson, P G; Nagel, S B; Saenz, A D; Simien, C E; Killian, Thomas C.

    2005-01-01

    Ultracold neutral plasmas are formed by photoionizing laser-cooled atoms near the ionization threshold. Through the application of atomic physics techniques and diagnostics, these experiments stretch the boundaries of traditional neutral plasma physics. The electron temperature in these plasmas ranges from 1-1000 K and the ion temperature is around 1 K. The density can approach $10^{11}$ cm$^{-3}$. Fundamental interest stems from the possibility of creating strongly-coupled plasmas, but recombination, collective modes, and thermalization in these systems have also been studied. Optical absorption images of a strontium plasma, using the Sr$^+$ ${^2S_{1/2}} -> {^2P_{1/2}}$ transition at 422 nm, depict the density profile of the plasma, and probe kinetics on a 50 ns time-scale. The Doppler-broadened ion absorption spectrum measures the ion velocity distribution, which gives an accurate measure of the ion dynamics in the first microsecond after photoionization.

  9. Pulsed plasma electron sourcesa)

    Science.gov (United States)

    Krasik, Ya. E.; Yarmolich, D.; Gleizer, J. Z.; Vekselman, V.; Hadas, Y.; Gurovich, V. Tz.; Felsteiner, J.

    2009-05-01

    There is a continuous interest in research of electron sources which can be used for generation of uniform electron beams produced at E ≤105 V/cm and duration ≤10-5 s. In this review, several types of plasma electron sources will be considered, namely, passive (metal ceramic, velvet and carbon fiber with and without CsI coating, and multicapillary and multislot cathodes) and active (ferroelectric and hollow anodes) plasma sources. The operation of passive sources is governed by the formation of flashover plasma whose parameters depend on the amplitude and rise time of the accelerating electric field. In the case of ferroelectric and hollow-anode plasma sources the plasma parameters are controlled by the driving pulse and discharge current, respectively. Using different time- and space-resolved electrical, optical, spectroscopical, Thomson scattering and x-ray diagnostics, the parameters of the plasma and generated electron beam were characterized.

  10. Plasma Therapy: An Overview

    Directory of Open Access Journals (Sweden)

    Rajkumar Diwan

    2011-01-01

    Full Text Available Definition: Plasma, the fourth state of matter, is a collection of charged particles (electrons, ions, neutral atoms. Recent demonstration of plasma technology in treatment of living cells, tissue and organs are creating a new field at the intersection of plasma science and technology with biology and medicine known as plasma medicine. Plasma medicine is one of the newest fields of modem applied plasma chemistry. It appeared several years ago and comprises studies concerning the direct action of low-temperature, one atmosphere air plasma (cold plasma/nonthermal plasmalnonequilibrium on body tissues for various noninvasive therapeutic treatments or diagnostics purpose. The study of plasma holds promise for a myriad of applications ranging from lasers and electronics, hazardous decontamination, sterilization and disinfection of foods, soil, water, instruments, to medical uses in wound healing and treating certain types of tumors and cancers. Plasma represents a new state-of-the-art sterilization and disinfection treatment for certain oral and environmental pathogens, heat-sensitive materials, hard and soft surfaces, and may assist health care facilities in the management of various health concerns. The role that low temperature atmospheric pressure plasma (LTAPP could play in the inactivation of pathogenic microorganisms might prove to be a new, faster, more economical alternative.

  11. IR thermography diagnostics for the WEST project

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, X., E-mail: xavier.courtois@cea.fr [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Aumeunier, M.H. [OPTIS, ZE de La Farlède, F-83078 Toulon Cedex 9 (France); Joanny, M.; Roche, H.; Micolon, F.; Salasca, S.; Balorin, C.; Jouve, M. [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France)

    2014-10-15

    Highlights: • The WEST project requires a set of three infrared diagnostics. • The tungsten divertor will be monitored by the existing diagnostic renewed. • The antennas monitoring require the development of an innovative diagnostic. • A fiber bundle will be used as image transport for the antennas monitoring. • A wide angle tangential view of the upper divertor and the first wall is studied. - Abstract: To operate long plasma discharge in tokamak equipped with actively cooled plasma facing components (PFC), infrared (IR) thermography is a key diagnostic. Indeed IR data are used for both PFC safety monitoring, to avoid material degradation and water leak, and various physics studies on plasma-wall interaction. The IR monitoring is becoming even more crucial with today metallic PFCs. This is the case for the WEST project (Tungsten (W) Environment for Steady State Tokamak), which aims at installing a W divertor in Tore Supra (TS), in order to operate the 1st tokamak with a full W actively cooled divertor in long plasma discharges. The IR thermography system for the WEST project described in this paper will consist of a set of 3 different diagnostics: (1) Six cameras located in upper ports viewing the full W divertor, which reuse a part of the existing diagnostic of TS. (2) Five novel views located behind the inner protection panels for the antennas monitoring, based on an innovative imaging fibers bundle technology. (3) A tangential wide angle view located in a median port, for the upper divertor and first wall monitoring.

  12. Optical boundary reconstruction of tokamak plasmas for feedback control of plasma position and shape

    NARCIS (Netherlands)

    Hommen, G.; de M. Baar,; Nuij, P.; McArdle, G.; Akers, R.; Steinbuch, M.

    2010-01-01

    A new diagnostic is developed to reconstruct the plasma boundary using visible wavelength images. Exploiting the plasma's edge localized and toroidally symmetric emission profile, a new coordinate transform is presented to reconstruct the plasma boundary from a poloidal view image. The plasma b

  13. Rotorcraft Diagnostics

    Science.gov (United States)

    Haste, Deepak; Azam, Mohammad; Ghoshal, Sudipto; Monte, James

    2012-01-01

    Health management (HM) in any engineering systems requires adequate understanding about the system s functioning; a sufficient amount of monitored data; the capability to extract, analyze, and collate information; and the capability to combine understanding and information for HM-related estimation and decision-making. Rotorcraft systems are, in general, highly complex. Obtaining adequate understanding about functioning of such systems is quite difficult, because of the proprietary (restricted access) nature of their designs and dynamic models. Development of an EIM (exact inverse map) solution for rotorcraft requires a process that can overcome the abovementioned difficulties and maximally utilize monitored information for HM facilitation via employing advanced analytic techniques. The goal was to develop a versatile HM solution for rotorcraft for facilitation of the Condition Based Maintenance Plus (CBM+) capabilities. The effort was geared towards developing analytic and reasoning techniques, and proving the ability to embed the required capabilities on a rotorcraft platform, paving the way for implementing the solution on an aircraft-level system for consolidation and reporting. The solution for rotorcraft can he used offboard or embedded directly onto a rotorcraft system. The envisioned solution utilizes available monitored and archived data for real-time fault detection and identification, failure precursor identification, and offline fault detection and diagnostics, health condition forecasting, optimal guided troubleshooting, and maintenance decision support. A variant of the onboard version is a self-contained hardware and software (HW+SW) package that can be embedded on rotorcraft systems. The HM solution comprises components that gather/ingest data and information, perform information/feature extraction, analyze information in conjunction with the dependency/diagnostic model of the target system, facilitate optimal guided troubleshooting, and offer

  14. Coronal diagnostics

    Directory of Open Access Journals (Sweden)

    J. C. Raymond

    2000-01-01

    Full Text Available Los cocientes de l neas de emisi on en el UV han permitido diagnosticar la densidad, temperatura, abundancias de elementos y el estado de ionizaci on de los plasmas astrof sicos. Con la nueva generaci on de sat elites de rayos-X, estas t ecnicas podr an usarse en los espectros de rayos-X. Es importante recordar que los cocientes proveen valores promediados a lo largo de la l nea de visi on y diferentes diagn osticos dar an valores pesados de forma diferente. Existen varias suposiciones impl citas en los an alisis de estos cocientes. En particular, se suele suponer que la profundi- dad optica es despreciable. Damos algunos ejemplos de las bondades de usar la dispersi on de fotones como una nueva herramienta de diagn ostico, ilustrando los peligros de usar los m etodos usuales cuando la opacidad es alta.

  15. Low temperature plasma technology methods and applications

    CERN Document Server

    Chu, Paul K

    2013-01-01

    Written by a team of pioneering scientists from around the world, Low Temperature Plasma Technology: Methods and Applications brings together recent technological advances and research in the rapidly growing field of low temperature plasmas. The book provides a comprehensive overview of related phenomena such as plasma bullets, plasma penetration into biofilms, discharge-mode transition of atmospheric pressure plasmas, and self-organization of microdischarges. It describes relevant technology and diagnostics, including nanosecond pulsed discharge, cavity ringdown spectroscopy, and laser-induce

  16. Spectroscopy of Low Temperature Plasma

    CERN Document Server

    Ochkin, Vladimir N

    2009-01-01

    Providing an up-to-date overview on spectroscopical diagnostics of low temperature plasma Spectroscopy of Low Temperature Plasma covers the latest developments and techniques. Written by a distinguished scientist and experienced book author this text is applicable to many fields in materials and surface science as well as nanotechnology and contains numerous appendices with indispensable reference data.

  17. Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER

    Energy Technology Data Exchange (ETDEWEB)

    Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.; Petrov, A. A.; Petrov, V. G.; Tugarinov, S. N. [Institution Project center ITER, Moscow (Russian Federation)

    2014-08-21

    In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and represent the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ–ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed.

  18. Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER

    Science.gov (United States)

    Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.; Petrov, A. A.; Petrov, V. G.; Tugarinov, S. N.

    2014-08-01

    In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and represent the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ-ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed.

  19. Experimental Plasma Research project summaries

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-09-01

    This report contains descriptions of the activities supported by the Experimental Plasma Research Branch of APP. The individual project summaries were prepared by the principal investigators and include objectives and milestones for each project. The projects are arranged in six research categories: Plasma Properties; Plasma Heating; Plasma Diagnostics; Atomic, Molecular and Nuclear Physics; Advanced Superconducting Materials; and the Fusion Plasma Research Facility (FPRF). Each category is introduced with a statement of objectives and recent progress and followed by descriptions of individual projects. An overall budget summary is provided at the beginning of the report.

  20. Diagnostic thoracoscopy

    Directory of Open Access Journals (Sweden)

    Plavec Goran

    2002-01-01

    Full Text Available Diagnostic thoracoscopy in patients with pleural effusion of unclear origin mostly provides the correct diagnosis. Results from published reports of previous researches are not uniform. In 47 male and 20 female patients with pleural effusion of unknown etiology, after receiving negative results obtained from cytological finding of pleural effusion and percutaneous needle biopsy, thoracoscopy with biopsy of one or both pleurae was performed. Procedure was done in local anesthesia using Stortz rigid thoracoscope. In 37 patients with malignant disease (primary or metastatic diagnosis was confirmed histopathologically in 31 patient (81.12%. In 27 patients with inflammatory pleural disease diagnosis was confirmed histopathologically in 22 patients (81.4%. Among 11 patients with specific pleural effusions, tuberculosis was confirmed in 10 (90.91%. Normal finding in cases of spontaneous pneumothorax and pulmonary embolism was taken as a positive result. Total number of positive findings was 55 (82.10%. In one patient, the third spontaneous pneumothorax was the indication for thoracoscopy, and after numerous bullae were seen during the procedure, talcum powder pleurodesis was done. In four patients low intensity subcutaneous emphysema occurred one day after thoracoscopy. It can be concluded that thoracoscopy in local anesthesia out of the operating room is good and practical method for solving the unclear pleural effusions, with neglectable rate of complications.

  1. The marker of cobalamin deficiency, plasma methylmalonic acid, correlates to plasma creatinine

    DEFF Research Database (Denmark)

    Hvas, A M; Juul, S; Gerdes, Lars Ulrik

    2000-01-01

    OBJECTIVE: To examine the relationship between the two diagnostic tests, plasma methylmalonic acid and plasma cobalamins, and their association with plasma creatinine, age and sex. DESIGN: Cross-sectional study of simultaneous laboratory measurements. SETTING: County of Aarhus, Denmark. SUBJECTS......: Records on 1689 patients who had their first plasma methylmalonic acid measurement during 1995 and 1996, and who had a simultaneous measurement of plasma cobalamins. Plasma creatinine values measured within a week of measurements of plasma methylmalonic acid and plasma cobalamins were available for 1255...... of the patients. MAIN OUTCOME MEASURES: Predictors of variation in plasma methylmalonic acid; plasma cobalamins, plasma creatinine, age and sex. RESULTS: Plasma methylmalonic acid was positively correlated with plasma creatinine, even for plasma creatinine within the normal range. These associations remained...

  2. Observations and diagnostics in high brightness beams

    Energy Technology Data Exchange (ETDEWEB)

    Cianchi, A., E-mail: alessandro.cianchi@roma2.infn.it [University of Rome Tor Vergata and INFN-Roma Tor Vergata, Via della Ricerca Scientifica 1, 00133 Rome (Italy); Anania, M.P.; Bisesto, F.; Castellano, M.; Chiadroni, E.; Pompili, R.; Shpakov, V. [INFN-LNF, Via Enrico Fermi 40, 00044 Frascati (Italy)

    2016-09-01

    The brightness is a figure of merit largely used in the light sources, like FEL (Free Electron Lasers), but it is also fundamental in several other applications, as for instance Compton backscattering sources, beam driven plasma accelerators and THz sources. Advanced diagnostics are essential tools in the development of high brightness beams. 6D electron beam diagnostics will be reviewed with emphasis on emittance measurement.

  3. DEMO diagnostics and burn control

    Energy Technology Data Exchange (ETDEWEB)

    Biel, Wolfgang, E-mail: w.biel@fz-juelich.de [Institute of Energy and Climate Research, Forschungszentrum Jülich GmbH, Jülich (Germany); Department of Applied Physics, Ghent University (Belgium); Baar, Marco de [FOM-Institute DIFFER, Nieuwegein (Netherlands); Eindhoven University of Technology (Netherlands); Dinklage, Andreas [Max-Planck-Institut für Plasmaphysik, Greifswald (Germany); Felici, Federico [Eindhoven University of Technology (Netherlands); König, Ralf [Max-Planck-Institut für Plasmaphysik, Greifswald (Germany); Meister, Hans; Treutterer, Wolfgang [Max-Planck-Institut für Plasmaphysik, Garching (Germany); Wenninger, Ronald [Max-Planck-Institut für Plasmaphysik, Garching (Germany); EFDA Power Plant Physics and Technology, Garching (Germany)

    2015-10-15

    Highlights: • An initial concept for the DEMO diagnostic and control system is presented. • A preliminary list of control functions and candidate diagnostics is developed. • Challenges regarding disruptions, power exhaust and radiation control are highlighted. • The need for introducing realistic control margins is emphasized. • On outline of the future R&D plan is presented. - Abstract: The development of the control system for a tokamak demonstration fusion reactor (DEMO) faces unprecedented challenges. First, the requirements for control reliability and accuracy are more stringent than on existing fusion devices: any loss of plasma control on DEMO may result in a disruption which could damage the inner wall of the machine, while operating the device with larger margins against the operational limits would lead to a reduction of the electrical output power. Second, the performance of DEMO control is limited by space restrictions for the implementation of components (optimization of the tritium breeding rate), by lifetime issues for the front-end parts (neutron and gamma radiation, erosion and deposition acting on all components) and by slow, weak and indirect action of the available actuators (plasma shaping, heating and fuelling). The European DEMO conceptual design studies include the development of a reliable control system, since the details of the achievable plasma scenario and the machine design may depend on the actual performance of the control system. In the first phase of development, an initial understanding of the prime choices of diagnostic methods applicable to DEMO, implementation and performance issues, the interrelation with the plasma scenario definition, and the planning of necessary future R&D have been obtained.

  4. Collected abstracts on particle beam diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Hickok, R.L.

    1979-01-01

    This report contains a compilation of abstracts on work related to particle beam diagnostics for high temperature plasmas. The abstracts were gathered in early 1978 and represent the status of the various programs as of that date. It is not suggested that this is a comprehensive list of all the work that is going on in the development of particle beam diagnostics, but it does provide a representative view of the work in this field. For example, no abstracts were received from the U.S.S.R. even though they have considerable activity in particle beam diagnostics.

  5. Development of a transient internal probe diagnostic

    Science.gov (United States)

    Spanjers, G. G.; Galambos, J. P.; Bohnet, M. A.; Jarboe, T. R.; Christiansen, W. H.; Wurden, G. A.; Wright, B. L.; Smith, R. J.

    1992-10-01

    The transient internal probe (TIP) diagnostic is a novel method for probing the interior of hot magnetic fusion plasmas. In the TIP scheme, a probe is fired, using a two-stage light gas gun, through a hot plasma at velocities up to 5 km/s, and makes direct, local measurements of the internal magnetic field structure. The data are relayed to the laboratory optical detection system using an incident laser that is directed through a Faraday rotator payload acting as a magneto-optic sensor. Ablative effects are avoided by minimizing the probe size, limiting the time that the probe is in the hot plasma, and encasing the probe with a diamond cladding. The degree to which the diamond probe cladding is susceptible to ablative effects will determine the plasma density and temperature regime in which the TIP diagnostic can be used. If the TIP suffers significant ablation it is an indication that the diagnostic is not usable on this hot and dense of a plasma (or that greater velocity must be imparted to the probe to further minimize the time that it is in the plasma). A quantitative experimental study of the ablation rates of diamond is planned as part of the TIP development. The integrated TIP system will be functional in 1992 and installed on the Helicity Injected Torus (HIT) [T. R. Jarboe, Fusion Tech. 15, 9 (1989)] at the University of Washington.

  6. Note: Infrared laser diagnostics for deuterium gas puff Z pinches

    Science.gov (United States)

    Ivanov, V. V.; McKee, E. S.; Hammel, B. D.; Darling, T. W.; Swanson, K. J.; Covington, A. M.

    2017-07-01

    Deuterium gas puff Z pinches have been used for generation of strong neutron fluxes on the MA class pulse power machines. Due to the low electron density of deuterium Z-pinch plasma, regular laser diagnostics in the visible range cannot be used for observation and study of the pinch. Laser probing at the wavelength of 1064 nm was used for visualization of deuterium plasma. Infrared schlieren and interferometry diagnostics showed the deuterium gas puff plasma dynamics, instabilities, and allowed for the reconstruction of the profile of the plasma density.

  7. Diagnostics spectroscopiques d'espèces carbonées et modélisation physico-chimique de plasmas micro-ondes dans les mélanges H2/CH4 et Ar/H2/CH4 utilisés pour le dépôt de diamant

    OpenAIRE

    Lombardi, Guillaume

    2003-01-01

    A. Gicquel (Examinatrice, Pr. Université Paris XIII) K. Hassouni (Examinateur, CR CNRS LIMHP, HDR) J. Perrin (Rapporteur, DR CNRS LPTP détaché Air Liquide) J.M. Rax (Président du jury, Pr. Université Paris XI) J. Röpcke (Examinateur, INP-Greifswald, Allemagne, HDR) N. Sadeghi (Rapporteur, DR CNRS LSP-Grenoble); The work presented in the frame of this thesis dealt with spectroscopic diagnostic and modelling of 2.45 GHz-microwave plasmas obtained under moderate pressure using a cavity coupling ...

  8. Diagnostic meaning of intestinal wall photoluminescence changes

    Science.gov (United States)

    Besaha, R. M.; Hrynchuk, F. V.; Polyansky, I. Y.

    2006-05-01

    Diagnostics of inflammatory-destructive diseases of the abdominal cavity organs is performed by the determined spectra of luminescence of venous blood plasma. The shift of the photoluminescence maximum beginning with the wave-length 469 nm into short-wave zone proves the presence of the acute inflammatory-destructive diseases and exacerbation of the pathological process.

  9. The LIDAR Thomson Scattering Diagnostic on JET

    DEFF Research Database (Denmark)

    Salzmann, H.; Bundgaard, J.; Gadd, A.

    1988-01-01

    By combining the time‐of‐flight or LIDAR principle with a Thomson backscatter diagnostic, spatial profiles of the electron temperature and density are measured in a magnetically confined fusion plasma. This technique was realized for the first time on the JET tokamak. A ruby laser (3‐J pulse energy...

  10. Understanding Micro Plasmas

    CERN Document Server

    Winter, J; Böke, M; Ellerweg, D; Hemke, T; Knake, N; Mussenbrock, T; Niermann, B; Schröder, D; der Gathen, V Schulz-von; von Keudell, A

    2011-01-01

    Micro plasmas are operated around atmospheric pressure exhibiting pronounced non-equilibrium characteristics, i.e. they possess energetic electrons while ions and neutrals remain cold. They have gained significant interest due to their enormous application potential e.g. in the biomedical, surface modification and light source areas, just to name a few. Many different configurations are in use. Their understanding and quantification is mandatory for further progress in applications. We report on recent progress in the diagnostics and simulation of the entire micro plasma system from gas introduction, via the plasma discharge up to the samples at the example of a plasma jet operated in He/O2 in an ambient air environment.

  11. Laser Wakefield diagnostic using holographic longitudinal interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Volfbeyn, P.; Esarey, E.; Leemans, W.P.

    1999-03-26

    We propose a diagnostic technique for wakefield measurement in plasma channels. A new technique for plasma channel creation, the Ignitor Heater scheme was proposed and experimentally tested in hydrogen and nitrogen previously. It makes use of two laser pulses. The Ignitor, an ultrashort (sub 100 fs) laser pulse, is brought to a line focus using a cylindrical lens to ionize the gas. The Heater pulse (160 ps long) is used to heat the existing spark via in-verse Bremsstrahlung. The hydrodynamic shock expansion creates a partially evacuated plasma channel with a density minimum on axis. Such a channel has properties of an optical waveguide. This technique allows creation of plasma channels in low atomic number gases, such as hydrogen, which is of importance for guiding of highly intense laser pulses. Laser pulses injected into such plasma channels produce a plasma wake that has a phase velocity close to the speed of light. A discussion of plasma wake measurements, using a Longitudinal Interferometry Wakefield Diagnostic Based on Time Domain Rayleigh Refractometry with Holographic Inversion, will be presented.

  12. Experimental and theoretical research in applied plasma physics. Technical progress report, October 15, 1990--October 14, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Porkolab, M.

    1992-06-01

    This report discusses research in the following areas: fusion theory and computations; theory of thermonuclear plasmas; user service center; high poloidal beta studies on PBX-M; fast ECE fluctuation diagnostic for balloning mode studies; x-ray imaging diagnostic; millimeter/submillimeter-wave fusion ion diagnostics; small scale turbulence and nonlinear dynamics in plasmas; plasma turbulence and transport; phase contrast interferometer diagnostic for long wavelength fluctuations in DIII-D; and charged and neutral fusion production for fusio plasmas.

  13. Plasma turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Horton, W. [Univ. of Texas, Austin, TX (United States). Inst. for Fusion Studies; Hu, G. [Globalstar LP, San Jose, CA (United States)

    1998-07-01

    The origin of plasma turbulence from currents and spatial gradients in plasmas is described and shown to lead to the dominant transport mechanism in many plasma regimes. A wide variety of turbulent transport mechanism exists in plasmas. In this survey the authors summarize some of the universally observed plasma transport rates.

  14. Plasma polarization spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, Takashi; Iwamae, Atsushi (eds.) [Kyoto Univ. (Japan). Dept. of Mechanical Engineering and Science

    2008-07-01

    Plasma Polarization Spectroscopy (PPS) is now becoming a standard diagnostic technique for working with laboratory plasmas. This new area needs a comprehensive framework, both experimental and theoretical. This book reviews the historical development of PPS, develops a general theoretical formulation to deal with this phenomenon, along with an overview of relevant cross sections, and reports on laboratory experiments so far performed. It also includes various facets that are interesting from this standpoint, e.g. X-ray lasers and effects of microwave irradiation. It also offers a timely discussion of instrumentation that is quite important in a practical PPS experiment. (orig.)

  15. Plasma Assisted Combustion

    Science.gov (United States)

    2007-02-28

    pressure hydrogen is given in Fig. 2.14. The regions typical for “common” glow discharges (negative glow, Faraday dark space, and positive column) are...Hollenstein Ch. Plasma Phys. Control. Fusion, 42 (2000) 93. [107] M.A. Heald and C.B. Wahrton, Plasma diagnostics with microwaves, John Wi- ley &Sons, New York...Nitrous Oxide J. Chem. Soc. Faraday Trans. 69 352 [194] Albers E A, Hoyermann K, Schacke H, Schmatjko K J, Wagner H Gg, Wolfrum J 1975 Absolute Rate

  16. Verification of Loop Diagnostics

    Science.gov (United States)

    Winebarger, A.; Lionello, R.; Mok, Y.; Linker, J.; Mikic, Z.

    2014-01-01

    Many different techniques have been used to characterize the plasma in the solar corona: density-sensitive spectral line ratios are used to infer the density, the evolution of coronal structures in different passbands is used to infer the temperature evolution, and the simultaneous intensities measured in multiple passbands are used to determine the emission measure. All these analysis techniques assume that the intensity of the structures can be isolated through background subtraction. In this paper, we use simulated observations from a 3D hydrodynamic simulation of a coronal active region to verify these diagnostics. The density and temperature from the simulation are used to generate images in several passbands and spectral lines. We identify loop structures in the simulated images and calculate the loop background. We then determine the density, temperature and emission measure distribution as a function of time from the observations and compare with the true temperature and density of the loop. We find that the overall characteristics of the temperature, density, and emission measure are recovered by the analysis methods, but the details of the true temperature and density are not. For instance, the emission measure curves calculated from the simulated observations are much broader than the true emission measure distribution, though the average temperature evolution is similar. These differences are due, in part, to inadequate background subtraction, but also indicate a limitation of the analysis methods.

  17. Energetic Particle Diagnostics for Transport Analysis 3.Escaping Fast Ion Diagnostics for the Fast Particle Transport Analysis

    Science.gov (United States)

    Isobe, Mitsutaka; Shinohara, Kouji

    Escaping energetic ion diagnostics in magnetically confined plasma experiments are described in this lecture note. Experimental results from escaping energetic ion diagnostics in TFTR, JFT-2M, CHS and W7-AS are shown. In addition to mechanism of energetic ion loss from a viewpoint of particle orbit, effect of MHD activity on energetic particle transport is reviewed.

  18. Fusion neutron diagnostics on ITER tokamak

    Science.gov (United States)

    Bertalot, L.; Barnsley, R.; Direz, M. F.; Drevon, J. M.; Encheva, A.; Jakhar, S.; Kashchuk, Y.; Patel, K. M.; Arumugam, A. P.; Udintsev, V.; Walker, C.; Walsh, M.

    2012-04-01

    ITER is an experimental nuclear reactor, aiming to demonstrate the feasibility of nuclear fusion realization in order to use it as a new source of energy. ITER is a plasma device (tokamak type) which will be equipped with a set of plasma diagnostic tools to satisfy three key requirements: machine protection, plasma control and physics studies by measuring about 100 different parameters. ITER diagnostic equipment is integrated in several ports at upper, equatorial and divertor levels as well internally in many vacuum vessel locations. The Diagnostic Systems will be procured from ITER Members (Japan, Russia, India, United States, Japan, Korea and European Union) mainly with the supporting structures in the ports. The various diagnostics will be challenged by high nuclear radiation and electromagnetic fields as well by severe environmental conditions (ultra high vacuum, high thermal loads). Several neutron systems with different sensitivities are foreseen to measure ITER expected neutron emission from 1014 up to almost 1021 n/s. The measurement of total neutron emissivity is performed by means of Neutron Flux Monitors (NFM) installed in diagnostic ports and by Divertor Neutron Flux Monitors (DNFM) plus MicroFission Chambers (MFC) located inside the vacuum vessel. The neutron emission profile is measured with radial and vertical neutron cameras. Spectroscopy is accomplished with spectrometers looking particularly at 2.5 and 14 MeV neutron energy. Neutron Activation System (NAS), with irradiation ends inside the vacuum vessel, provide neutron yield data. A calibration strategy of the neutron diagnostics has been developed foreseeing in situ and cross calibration campaigns. An overview of ITER neutron diagnostic systems and of the associated challenging engineering and integration issues will be reported.

  19. Discovery and validation of plasma-protein biomarker panels for the detection of colorectal cancer and advanced adenoma in a Danish collection of samples from patients referred for diagnostic colonoscopy

    DEFF Research Database (Denmark)

    Blume, John E.; Wilhelmsen, Michael; Benz, Ryan W.

    2016-01-01

    and utilization of such a resou