WorldWideScience

Sample records for plasma concentration measurement

  1. Measurement of plasma adenosine concentration: methodological and physiological considerations

    International Nuclear Information System (INIS)

    Gewirtz, H.; Brown, P.; Most, A.S.

    1987-01-01

    This study tested the hypothesis that measurements of plasma adenosine concentration made on samples of blood obtained in dipyridamole and EHNA (i.e., stopping solution) may be falsely elevated as a result of ongoing in vitro production and accumulation of adenosine during sample processing. Studies were performed with samples of anticoagulated blood obtained from anesthesized domestic swine. Adenosine concentration of ultra filtrated plasma was determined by HPLC. The following parameters were evaluated: (i) rate of clearance of [ 3 H]adenosine added to plasma, (ii) endogenous adenosine concentration of matched blood samples obtained in stopping solution alone, stopping solution plus EDTA, and perchloric acid (PCA), (iii) plasma and erythrocyte endogenous adenosine concentration in nonhemolyzed samples, and (iv) plasma adenosine concentration of samples hemolyzed in the presence of stopping solution alone or stopping solution plus EDTA. We observed that (i) greater than or equal to 95% of [ 3 H]adenosine added to plasma is removed from it by formed elements of the blood in less than 20 s, (ii) plasma adenosine concentration of samples obtained in stopping solution alone is generally 10-fold greater than that of matched samples obtained in stopping solution plus EDTA, (iii) deliberate mechanical hemolysis of blood samples obtained in stopping solution alone resulted in substantial augmentation of plasma adenosine levels in comparison with matched nonhemolyzed specimens--addition of EDTA to stopping solution prevented this, and (iv) adenosine content of blood samples obtained in PCA agreed closely with the sum of plasma and erythrocyte adenosine content of samples obtained in stopping solution plus EDTA

  2. Measurement of plasma homovanillic acid concentrations in schizophrenic patients.

    Science.gov (United States)

    Kaminski, R; Powchick, P; Warne, P A; Goldstein, M; McQueeney, R T; Davidson, M

    1990-01-01

    1. Several lines of evidence suggest that abnormalities of central dopaminergic transmission may be involved in the expression of some schizophrenic symptoms. However, elucidation of the role of dopamine (DA) in schizophrenia has eluded investigative efforts partially because no accurate and easily repeatable measure of brain DA activity exists. 2. The development of a technique to measure homovanillic acid in plasma has offered the possibility of performing serial measurements of this major DA metabolite. 3. Assuming that plasma homovanillic acid (PHVA) concentrations is an index of brain DA activity, measurement of PHVA can play a role in elucidating the DA abnormality in schizophrenia. 4. Results to date suggest that plasma homovanillic acid concentrations are lower in chronic schizophrenic patients compared to normal controls, and that PHVA values correlate with schizophrenic symptom severity. 5. In addition, PHVA levels were shown to initially rise and subsequently decline during chronic neuroleptic administration in treatment responsive but not in treatment refractory schizophrenic patients.

  3. Laser system for measuring small changes in plasma tracer concentrations.

    Science.gov (United States)

    Klaesner, J W; Pou, N A; Parker, R E; Galloway, R L; Roselli, R J

    1996-01-01

    The authors developed a laser-diode system that can be used for on-line optical concentration measurements in physiologic systems. Previous optical systems applied to whole blood have been hampered by artifacts introduced by red blood cells (RBCs). The system introduced here uses a commercially available filter cartridge to separate RBCs from plasma before plasma concentration measurements are made at a single wavelength. The filtering characteristics of the Cellco filter cartridge (#4007-10, German-town, MD) were adequate for use in the on-line measurement system. The response time of the filter cartridge was less than 40 seconds, and the sieving characteristics of the filter for macromolecules were excellent, with filtrate-to-plasma albumin ratios of 0.98 +/- 0.11 for studies in sheep and 0.94 +/- 0.15 for studies in dogs. The 635-nm laser diode system developed was shown to be more sensitive than the spectrophotometer used in previous studies (Klaesner et al., Annals of Biomedical Engineering, 1994; 22, 660-73). The new system was used to measure the product of filtration coefficient (Kfc) and reflection coefficient for albumin (delta f) in an isolated canine lung preparation. The delta fKfc values [mL/(cmH2O.min.100 g dry lung weight)] measured with the laser diode system (0.33 +/- 0.22) compared favorably with the delta fKfc obtained using a spectrophotometer (0.27 +/- 0.20) and with the Kfc obtained using the blood-corrected gravimetric method (0.32 +/- 0.23). Thus, this new optical system was shown to accurately measure plasma concentration changes in whole blood for physiologic levels of Kfc. The same system can be used with different optical tracers and different source wavelengths to make optical plasma concentration measurements for other physiologic applications.

  4. Laser-Based Optical System for Reactive Radical Concentration Measurements in Plasmas and Flames

    National Research Council Canada - National Science Library

    Fridman, Alexander

    2006-01-01

    Defense University Research Instrumentation Program (DURIP) funding was used to assemble a multi-purpose optical diagnostic system for in-situ radical concentration measurements in plasma and combustion systems...

  5. Plasma concentrations of blood coagulation factor VII measured by immunochemical and amidolytic methods

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Gram, J; Jespersen, J

    2000-01-01

    Ever since the coagulant activity of blood coagulation factor VII (FVII:C) was identified as a risk indicator of cardiac death, a large number of studies have measured FVII protein concentrations in plasma. FVII protein concentrations are either measured immunologically with an ELISA method (FVII...

  6. Determination of deuterium concentrations in JET plasmas from fusion reaction rate measurements

    International Nuclear Information System (INIS)

    Jarvis, O.N.; Balet, B.; Cordey, J.G.; Morgan, P.D.; Sadler, G.; Belle, P. van; Conroy, S.; Elevant, T.

    1989-01-01

    The concentration of deuterium in the central regions of JET plasmas, expressed as a fraction of the electron concentration (n d /n e ), has been determined using four different methods involving neutron detection. These measurements are found to be consistent and agree within experimental errors with values deduced from Z eff measurements using visible bremsstrahlung radiation. (author) 11 refs., 1 fig., 1 tab

  7. Processing-independent proANP measurement for low concentrations in plasma

    DEFF Research Database (Denmark)

    Mark, Peter D; Hunter, Ingrid; Terzic, Dijana

    2018-01-01

    BACKGROUND: Decreased concentrations of pro-atrial-derived natriuretic peptides (proABP) in plasma have been associated with obesity and suggested as a predictor of type 2 diabetes. However, assays for measuring proANP are generally aimed to quantitate higher concentrations of proANP associated...

  8. Measurement of cytoplasmic Ca2+ concentration in Saccharomyces cerevisiae induced by air cold plasma

    Science.gov (United States)

    Xiaoyu, DONG

    2018-03-01

    In this study, a novel approach to measure the absolute cytoplasmic Ca2+ concentration ([Ca2+]cyt) using the Ca2+ indicator fluo-3 AM was established. The parameters associated with the probe fluo-3 AM were optimized to accurately determine fluorescence intensity from the Ca2+-bound probe. Using three optimized parameters (final concentration of 6 mM probe, incubation time of 135 min, loading probe before plasma treatment), the maximum fluorescence intensity (F max = 527.8 a.u.) and the minimum fluorescence intensity (F min = 63.8 a.u.) were obtained in a saturated Ca2+ solution or a solution of lacking Ca2+. Correspondingly, the maximum [Ca2+]cyt induced by cold plasma was 1232.5 nM. Therefore, the Ca2+ indicator fluo-3 AM was successfully applied to measure the absolute [Ca2+]cyt in Saccharomyces cerevisiae stimulated by cold plasma at atmospheric air pressure.

  9. Saliva oxytocin measures do not reflect peripheral plasma concentrations after intranasal oxytocin administration in men.

    Science.gov (United States)

    Quintana, Daniel S; Westlye, Lars T; Smerud, Knut T; Mahmoud, Ramy A; Andreassen, Ole A; Djupesland, Per G

    2018-05-16

    Oxytocin plays an important role in social behavior. Thus, there has been significant research interest for the role of the oxytocin system in several psychiatric disorders, and the potential of intranasal oxytocin administration to treat social dysfunction. Measurement of oxytocin concentrations in saliva are sometimes used to approximate peripheral levels of oxytocin; however, the validity of this approach is unclear. In this study, saliva and plasma oxytocin was assessed after two doses of Exhalation Delivery System delivered intranasal oxytocin (8 IU and 24 IU), intravenous oxytocin (1 IU) and placebo in a double-dummy, within-subjects design with men. We found that intranasal oxytocin (8 IU and 24 IU) administration increased saliva oxytocin concentrations in comparison to saliva oxytocin concentration levels after intravenous and placebo administration. Additionally, we found that saliva oxytocin concentrations were not significantly associated with plasma oxytocin concentrations after either intranasal or intravenous oxytocin administration. Altogether, we suggest that saliva oxytocin concentrations do not accurately index peripheral oxytocin after intranasal or intravenous oxytocin administration, at least in men. The data indicates that elevated oxytocin saliva levels after nasal delivery primarily reflect exogenous administered oxytocin that is cleared from the nasal cavity to the oropharynx, and is therefore a weak surrogate for peripheral blood measurements. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Plasma assisted measurements of alkali metal concentrations in pressurized combustion processes

    International Nuclear Information System (INIS)

    Hernberg, R.; Haeyrinen, V.

    1995-01-01

    The plasma assisted method for continuous measurement of alkali metal concentrations in product gas flows of pressurized energy processes will be tested and applied at the 1.6 MW PFBC/G facility at Delft University of Technology in the Netherlands. Measurements will be performed during 1995 and 1996 at different stages of the research programme. The results are expected to give information about the influence of different process conditions on the generation of alkali metal vapours, the comparison of different methods for alkali measurement and the specific performance of our system. The project belongs to the Joule II extension program under contract JOU2-CT93-0431. (author)

  11. Rapid measurement of plasma free fatty acid concentration and isotopic enrichment using LC/MS

    Science.gov (United States)

    Persson, Xuan-Mai T.; Błachnio-Zabielska, Agnieszka Urszula; Jensen, Michael D.

    2010-01-01

    Measurements of plasma free fatty acids (FFA) concentration and isotopic enrichment are commonly used to evaluate FFA metabolism. Until now, gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) was the best method to measure isotopic enrichment in the methyl derivatives of 13C-labeled fatty acids. Although IRMS is excellent for analyzing enrichment, it requires time-consuming derivatization steps and is not optimal for measuring FFA concentrations. We developed a new, rapid, and reliable method for simultaneous quantification of 13C-labeled fatty acids in plasma using high-performance liquid chromatography-mass spectrometry (HPLC/MS). This method involves a very quick Dole extraction procedure and direct injection of the samples on the HPLC system. After chromatographic separation, the samples are directed to the mass spectrometer for electrospray ionization (ESI) and analysis in the negative mode using single ion monitoring. By employing equipment with two columns connected parallel to a mass spectrometer, we can double the throughput to the mass spectrometer, reducing the analysis time per sample to 5 min. Palmitate flux measured using this approach agreed well with the GC/C/IRMS method. This HPLC/MS method provides accurate and precise measures of FFA concentration and enrichment. PMID:20526002

  12. Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements

    Directory of Open Access Journals (Sweden)

    Jeffrey Viviano

    2016-03-01

    Full Text Available In this article we present data on the concentration of calcium as determined by Inductively Coupled Plasma (ICP measurements. Calcium was estimated in the reagents used for native gel electrophoresis of Neuronal Calcium Sensor (NCS proteins. NCS proteins exhibit calcium-dependent mobility shift in native gels. The sensitivity of this shift to calcium necessitated a precise determination of calcium concentrations in all reagents used. We determined the calcium concentrations in different components used along with the samples in the native gel experiments. These were: 20 mM Tris pH 7.5, loading dye and running buffer, with distilled water as reference. Calcium determinations were through ICP measurements. It was found that the running buffer contained calcium (244 nM over the blank. Keywords: Neuronal calcium sensor proteins, Electrophoresis, Mobility shift, Calcium, Magnesium

  13. Impurity identifications, concentrations and particle fluxes from spectral measurements of the EXTRAP T2R plasma

    Science.gov (United States)

    Menmuir, S.; Kuldkepp, M.; Rachlew, E.

    2006-10-01

    An absolute intensity calibrated 0.5 m spectrometer with optical multi-channel analyser detector was used to observe the visible-UV radiation from the plasma in the EXTRAP T2R reversed field pinch experiment. Spectral lines were identified indicating the presence of oxygen, chromium, iron and molybdenum impurities in the hydrogen plasma. Certain regions of interest were examined in more detail and at different times in the plasma discharge. Impurity concentration calculations were made using the absolute intensities of lines of OIV and OV measured at 1-2 ms into the discharge generating estimates of the order of 0.2% of ne in the central region rising to 0.7% of ne at greater radii for OIV and 0.3% rising to 0.6% for OV. Edge electron temperatures of 0.5-5 eV at electron densities of 5-10×1011 cm-3 were calculated from the measured relative intensities of hydrogen Balmer lines. The absolute intensities of hydrogen lines and of multiplets of neutral chromium and molybdenum were used to determine particle fluxes (at 4-5 ms into the plasma) of the order 1×1016, 7×1013 and 3×1013 particles cm-2 s-1, respectively.

  14. Diagnostics of PF-1000 facility operation and plasma concentration on the basis of spectral measurements

    International Nuclear Information System (INIS)

    Skladnik-Sadowska, E.; Malinowski, K.; Sadowski, M.J.; Scholz, M.; Tsarenko, A.V.

    2005-01-01

    The paper concerns the monitoring of the operation of high-current pulse discharges and the determination of the plasma concentration within the dense magnetized plasma column by means of optical spectroscopy methods. In experiments performed within the large PF-1000 facility, which is operated at IPPLM in Warsaw, particular attention was paid to possibility of the determination of correctness of the operational mode. In order to measure the visible radiation (VR), as emitted from the collapsing current sheath and the dense pinch region, the use was made of the MECHELLE R 900-optical-spectrometer, which was equipped with a CCD measuring head. The spectral measurements were performed at an angle of about 650 to the symmetry axis of the PF electrode system, through an optical window and a special collimator coupled with the quartz optical-cable. The observed VR emission originated from a part of the inner- and outer-electrode surfaces, the collapsing current-sheath layer and a portion of the dense plasma pinch-region (located a distance of 40-50 mm from the electrode ends). Considerable differences were found in the optical spectra recorded for so-called good shots and for cases of some failures. In the case of a breakdown (damage) of the main insulator there were observed different Al-lines, which originated from the eroded insulator material. At so-called bad vacuum conditions there were recorded various C-lines, and at an uncontrolled air-leakage into the experimental chamber there appeared numerous N-lines. The appearance of these characteristic spectral lines made possible to determine whether the operation of the PF-1000 facility was correct or incorrect. The paper reports also on estimates of plasma concentration values, which have been performed on the basis of a quantitative analysis of the Stark broadening of the selected spectral lines. (author)

  15. Plasma assisted measurements of alkali metal concentrations in pressurized combustion processes

    Energy Technology Data Exchange (ETDEWEB)

    Hernberg, R.; Haeyrinen, V. [Tampere Univ. of Technology (Finland). Dept. of Physics

    1996-12-01

    The plasma assisted method for continuous measurement of alkali concentrations in product gas flows of pressurized energy processes will be tested and applied at the 1.6 MW PFBC/G facility at Delft University of Technology in the Netherlands. During the reporting period the alkali measuring device has been tested under pressurized conditions at VTT Energy, DMT, Foster-Wheeler Energia and ABB Carbon. Measurements in Delft will be performed during 1996 after installation of the hot gas filter. The original plan for measurements in Delft has been postponed due to schedule delays in Delft. The results are expected to give information about the influence of different process conditions on the generation of alkali vapours, the comparison of different methods for alkali measurement and the specific performance of our system. This will be the first test of the plasma assisted measurement method in a gasification process. The project belongs to the Joule II extension program under contract JOU2-CT93-0431. (author)

  16. Ion mobility spectrometry as a simple and rapid method to measure the plasma propofol concentrations for intravenous anaesthesia monitoring

    Science.gov (United States)

    Wang, Xin; Zhou, Qinghua; Jiang, Dandan; Gong, Yulei; Li, Enyou; Li, Haiyang

    2016-11-01

    The plasma propofol concentration is important information for anaesthetists to monitor and adjust the anaesthesia depth for patients during a surgery operation. In this paper, a stand-alone ion mobility spectrometer (IMS) was constructed for the rapid measurement of the plasma propofol concentrations. Without any sample pre-treatment, the plasma samples were dropped on a piece of glass microfiber paper and then introduced into the IMS cell by the thermal desorption directly. Each individual measurement could be accomplished within 1 min. For the plasma propofol concentrations from 1 to 12 μg mL-1, the IMS response was linear with a correlation coefficient R2 of 0.998, while the limit of detection was evaluated to be 0.1 μg mL-1. These measurement results did meet the clinical application requirements. Furthermore, other clinically-often-used drugs, including remifentanil, flurbiprofen and atracurium, were found no significant interference with the qualitative and quantitative analysis of the plasma propofol. The plasma propofol concentrations measured by IMS were correlated well with those measured by the high performance liquid chromatography (HPLC). The results confirmed an excellent agreement between these two methods. Finally, this method was applied to monitor the plasma propofol concentrations for a patient undergoing surgery, demonstrating its capability of anaesthesia monitoring in real clinical environments.

  17. Plasma concentrations of misonidazole

    Energy Technology Data Exchange (ETDEWEB)

    Notter, G; Rylander, U; Turesson, I

    1980-10-01

    The plasma concentrations of misonidazole doses between 0.6 and 2.0 g/m/sup 2/ were analyzed in respect to the variation within the same patient and between different patients. Peak plasma levels were observed after 2 hours. The mean plasma levels of misonidazole only at 3 hours were 23.8, 47.0 and 76.5 ..mu..g/ml after misonidazole doses of 0.6, 1.2 g/m/sup 2/, respectively. The half-life of misonidazole only was found to be 8.2 hours for women and 10.5 for men. Good linearity between plasma levels and drug doses was observed after administration of different single doses to the same patient within the dose range 0.6 to 2.0 g/m/sup 2/.

  18. Measurement of excitation, ionization, and electron temperatures and positive ion concentrations in a 144 MHz inductively coupled radiofrequency plasma

    International Nuclear Information System (INIS)

    Walters, P.E.; Chester, T.L.; Winefordner, J.D.

    1977-01-01

    Diagnostic measurements of 144 MHz radiofrequency inductively coupled plasmas at pressures between 0.5 and 14 Torr have been made. Other variables studied included the gas type (Ar or Ne) and material in plasma (Ti or Tl). Parameters measured included excitation temperatures via the atomic Boltzmann plot and the two-line method, ionization electric probes. Excitation temperatures increased as the pressure of Ar or Ne plasmas decreased and reached a maximum of approx.9000 degreeK in the latter case and approx.6700 degreeK in the former case; Tl in the Ar plasma resulted in in a smaller rate of decrease of excitation temperature with increase of pressure of Ar. The ionization temperatures were lower than the excitation temperatures and were similar for both the Ar and Ne plasmas. Electron temperatures were about 10 times higher than the excitation temperatures indicating non-LTE behavior. Again, the electron temperatures indicating in Ne were considerably higher than in Ar. With the presence of metals, the electron temperatures with a metal in the Ar plasma were higher than in the absence. Positive ion concentrations were also measured for the various plasmas and were found to be similar (approx.10 18 m -3 ) in both the Ar and Ne plasmas. The presence of metals caused significant increase in the positive ion concentrations. From the results obtained, the optimum Ar pressure for Tl electrodeless discharge lamps operated at 144 MHz would be between 2 and 4 Torr

  19. IFCC reference measurement procedure for substance concentration determination of total carbon dioxide in blood, plasma or serum

    NARCIS (Netherlands)

    Burnett, RW; Covington, AK; Fogh-Andersen, N; Kulpmann, WR; Lewenstam, A; Mas, AHJ; VanKessel, AL; Zijlstra, WG

    A reference measurement procedure for substance concentration determination of total CO, in blood, plasma (the anticoagulant is usually heparin) or serum is described. The document covers the principle of the method, the materials and equipment needed and essential aspects of the procedure. The

  20. Measurement of concentrations of whole blood levels of choline, betaine, and dimethylglycine and their relations to plasma levels.

    Science.gov (United States)

    Awwad, Hussain Mohamad; Kirsch, Susanne H; Geisel, Juergen; Obeid, Rima

    2014-04-15

    We aimed at developing a method for the measurement of choline and its metabolites in whole blood (WB). After an extraction step, quantification of choline, betaine, and dimethylglycine (DMG) was performed using ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). Plasma and WB metabolites were evaluated in a group of 61 elderly people. The calibration curves were linear (r(2)>0.997) for all compounds. The inter- and intra-assay coefficients of variation for all analytes were 90% and the relative matrix effect were ≤4.0%. The median concentrations of choline, betaine, and DMG were 11.3, 27.8, and 5.9μmol/L in plasma and 66.6, 165, and 13.7μmol/L in WB, respectively. There were positive correlations between WB and plasma markers; for choline (r=0.42), betaine (r=0.61), and DMG (r=0.56) (all p≤0.001). The concentrations of betaine in WB and plasma were significantly higher in men than in women. The concentrations of WB choline and DMG did not differ significantly according to sex. In conclusion, we have established a reliable method for measuring choline metabolites in WB. The concentrations of WB choline, betaine, and DMG seem to reflect intracellular concentrations of these metabolites. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Measurement of plasma gentamicin concentrations postchemical ciliary body ablation in dogs with chronic glaucoma.

    Science.gov (United States)

    Rankin, Amy J; Lanuza, Rick; KuKanich, Butch; Crumley, William C; Pucket, Jonathan D; Allbaugh, Rachel A; Meekins, Jessica M

    2016-01-01

    To investigate the absorption of gentamicin into the plasma after an intravitreal injection in dogs and to report the success rate of this procedure in lowering the intraocular pressure. Twenty-four client-owned dogs with chronic, end-stage glaucoma. Dogs received a unilateral (22) or bilateral (2) intravitreal injection of 25-40 mg of gentamicin (mean ± SD dose 2.57 ± 1.65 mg/kg and range 0.61-7.50 mg/kg) and 1 mg of dexamethasone per eye. Blood samples were collected at various time points following the intravitreal injection. Plasma concentrations of gentamicin were determined by liquid chromatography and mass spectrometry. The total plasma concentration of gentamicin ranged from 0.21 to 9.71 μg/mL (mean ± SD 2.15 ± 2.03). The mean gentamicin CMAX was 2.29 μg/mL at 2.54 h with a terminal half-life of 9.8 h. The success rate of the chemical ablation procedure was 86.4% (19/22 eyes) in dogs that had at least 1 month of follow-up. Intravitreal injection of gentamicin in eyes with chronic glaucoma resulted in detectable plasma levels in dogs and was successful in lowering the intraocular pressure in 86.4% of the eyes after the first procedure. © 2015 American College of Veterinary Ophthalmologists.

  2. Plasma assisted measurements of alkali metal concentrations in pressurised combustion processes

    Energy Technology Data Exchange (ETDEWEB)

    Hernberg, R; Haeyrinen, V [Tampere Univ. of Technology (Finland)

    1997-10-01

    In this project the continuous alkali measurement method plasma excited alkali resonance line spectroscopy (PEARLS) was developed, tested and demonstrated in pressurised combustion facilities. The PEARLS method has been developed at Tampere University of Technology (TUT). During 1994-1996 the PEARLS method was developed from the laboratory level to an industrial prototype. The alkali measuring instrument has been tested and used for regular measurements in four different pressurised combustion installations ranging up to industrial pilot scale. The installations are: (1) a pressurised entrained flow reactor (PEFR) at VTT Energy in Jyvaeskylae, Finland (2) a pressurised fluidised bed combustion facility, called FRED, at DMT in Essen, Germany. (3) a 10 MW pressurised circulating fluidised bed combustion pilot plant at Foster Wheeler Energia Oy in Karhula, Finland (4) PFBC Research Facility at ABB Carbon in Finspaang, Sweden

  3. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  4. Plasma concentration of acetylcholine in young women

    International Nuclear Information System (INIS)

    Kawashima, K.; Oohata, H.; Fujimoto, K.; Suzuki, T.

    1987-01-01

    A sensitive and specific radioimmunoassay was applied to the determination of acetylcholine (ACh) in plasma. The concentration of ACh in plasma sampled from 32 young women was 456.1+-53.1 (mean +-S.E.M.) pg/ml. No significant correlations were observed between plasma concentrations of ACh and acetylcholinesterase (AChE) activity, or gonadal hormones. These data demonstrate that an amount of ACh measurable by radioimmunoassay is present in plasma and plasma ACh is not regulated by AChE activity and the menstrual cycle in young women. The origin and physiological as well as pathophysiological significance of ACh in plasma remain to be clarified. 13 refs. (Author)

  5. Gastric emptying in rats following administration of a range of different fats measured as acetaminophen concentration in plasma

    DEFF Research Database (Denmark)

    Porsgaard, Trine; Straarup, Ellen Marie; Høy, Carl-Erik

    2003-01-01

    an indirect measure of gastric emptying. Emulsified fats with added acetaminophen were fed by gavage to rats, and the plasma concentration of acetaminophen was followed for 3 h by repeated blood sampling from the carotid artery. The fats administered included rapeseed, corn, and fish oils, lard, and cocoa...... in gastric emptying between the groups fed the different fats, except for the emptying of tridecanoin (tri-10:0) that was statistically significantly slower than that of randomized oil, cocoa butter, and rapeseed oil (p

  6. Measurement of total and free docetaxel concentration in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Rigo-Bonnin, Raül; Cobo-Sacristán, Sara; Gonzalo-Diego, Núria; Colom, Helena; Muñoz-Sánchez, Carmen; Urruticoechea, Ander; Falo, Catalina; Alía, Pedro

    2016-01-05

    Docetaxel is a semi-synthetic taxane with cytotoxic anti-neoplastic activity and, currently used as anticancer agent in several types of cancer. Docetaxel is highly bound to plasma proteins, and this significantly determines its clearance and activity. Therefore, measurement of free docetaxel in plasma is pharmacologically important when pharmacokinetics is investigated. We developed and validated chromatographic methods by ultra-performance liquid chromatography-tandem mass spectrometry to measure total and free docetaxel concentration in human plasma. The final validated methods involved liquid-liquid extraction followed by dryness under nitrogen evaporation. To measure free docetaxel concentration, sample preparation was preceded by ultrafiltration. Chromatographic separation was achieved using an Acquity(®) UPLC(®) BEH™ (2.1×100 mm id, 1.7 μm) reverse-phase C18 column at a flow rate of 0.4 mL/min, using isocratic elution mode containing ammonium acetate/formic acid in water/methanol (30:70 v/v) as mobile phase. Docetaxel and its internal standard (paclitaxel) were detected by electrospray ionization mass spectrometry in positive ion multiple reaction monitoring mode using mass-to-charge (m/z) transitions of 808.3→527.0 (quantifier) and 808.3→509.0 (qualifier); and 854.3→569.0 (quantifier) and 854,3→509,0 (qualifier), respectively. The run time per sample was 3.5 min. The limits of quantification were 1,95 and 0.42 μg/L and linearity was observed between 1.95 and 1000 and 0.42-100 μg/L for total and free docetaxel, respectively. Coefficients of variation and absolute relative biases were less than 13.8% and 10.0%. Recovery values were greater than 79.4%. Evaluation of the matrix effect showed ion suppression and no carry-over was observed. The validated methods could be useful for both therapeutic drug monitoring and pharmacokinetic studies. They could be applied to daily clinical laboratory practice to measure the concentration of total and free

  7. REAL INTAKE AND PROVISION WITH VITAMINS AND CALCIUM IN OSTEOPOROSIS: ASSESSMENT BY MEASURING INTAKE AND PLASMA CONCENTRATIONS

    Directory of Open Access Journals (Sweden)

    V. N. Khodyrev

    2014-01-01

    Full Text Available Aim:  To assess the providing an organism with vitamins (А, В2, С, Е, β-carotene, and calcium in osteoporosis patients by measuring their intake and plasma concentrations. Materials and methods: 108 pairs “osteoporosis patient – healthy volunteer” aged 64.29±9.73 years were formed using a “case-control” method. Real intake of vitamins and calcium was studied defining the frequency of food taking for a month using questionnaire method. Daily intake of vitamins А, В2, С, Е, β-carotene, and calcium was calculated based on the analysis of the frequency of food taking. Among the basic group, using randomized method, 60% of osteoporosis patients were selected who underwent definition of plasma levels of vitamins А, В2, С, and Е. The same study was performed in 60 control volunteers. Results: Correlation of the intake of vitamins A, C, and β-carotene with their plasma levels wasn’t noted. It may reveal an increased need in these nutrients in osteoporosis. According to the calcium intake, every osteoporosis patient can be attributed to a population category with deep insufficiency of calcium intake (less than 500 mg a day. Conclusion: The data obtained need further investigation and, first of all, in clinical and biochemical fields (enzymatic non-provision for calcium uptake, clinical manifestations of insufficient provision with nutrients. Solution of these problems would enable regulation of food intake concerning calcium uptake in osteoporosis.

  8. Plasma leptin concentration in donkeys.

    Science.gov (United States)

    Díez, E; López, I; Pérez, C; Pineda, C; Aguilera-Tejero, E

    2012-01-01

    Donkeys appear to be more predisposed than large breed horses to suffer from hyperlipemia. The reason for that predisposition is unknown but anorexia is a consistent feature of the disease. Leptin, a protein synthesized in fat tissue, is one of the major inhibitors of appetite in mammals. We hypothesized that donkeys could have elevated plasma leptin concentrations compared to horses. Blood samples were obtained from 50 donkeys for measurement of leptin, triglycerides (TGs), glucose, and insulin. Glucose/insulin ratio, modified insulin to glucose ratio, and reciprocal of the square root of insulin were calculated. Based on their body condition score (BCS), donkeys were classified as lean (n = 18), normal (n = 16), or overweight (n = 16). The results were compared with reference values from our laboratory and with a group of horses (n = 25) used as an internal control. Values of both leptin and TGs in donkeys were above the horse reference range and also significantly higher than those of the control horses: leptin (11.2 ± 1.7 versus 5.8 ± 0.5 µg/L, p donkeys had leptin (19.3 ± 2.9 µg/L) and TG (1.3 ± 0.2 mmol/L) concentrations that were significantly (p donkeys. A significant positive correlation (p Donkeys have higher plasma leptin concentrations than horses and leptin is correlated with BCS.

  9. The effect of diet and exercise on plasma metabolilte and hormone concentrations in horses measured before and after exercise

    DEFF Research Database (Denmark)

    Jensen, Rasmus Bovbjerg; Blache, D.; Bach Knudsen, K E

    2017-01-01

    :00), and plasma samples were analysed for relevant metabolites and hormones. Plasma leptin concentrations increased after exercise but were not affected by diet, whereas diet and exercise had no effect on the plasma concentrations of ghrelin and insulin like growth factor 1 (IGF-1). Furthermore, diet influenced......Exercise influences different endocrine and metabolic parameters, and information in the literature is sparse for some of these hormones and metabolites in the exercising horse. The aim of the present experiment was to study the metabolic response to exercise when feeding diets with varying...... carbohydrate composition (fibre and starch) under experimental conditions where diet and exercise were standardised and controlled. The response was investigated in a 4×4 Latin square design experiment using four Norwegian Coldblooded trotter horses. The dietary treatments were two fibre based diets, hay only...

  10. Ammonia concentrations in canine whole blood, EDTA-anticoagulated whole blood, and plasma measured by use of a point-of-care ammonia meter.

    Science.gov (United States)

    Odunayo, Adesola; Tobias, Karen M; Okafor, Chika C; Flatland, Bente

    2017-11-01

    OBJECTIVE To investigate the use of canine whole blood (WB) for measurement of ammonia concentration by use of a point-of-care ammonia meter and to compare results of measuring ammonia concentrations in WB, EDTA-anticoagulated WB, and plasma. ANIMALS 40 client-owned dogs. PROCEDURES A blood sample (2 mL) was obtained from each dog. One drop of WB was immediately applied to a test strip for evaluation with an ammonia meter. The remainder of the blood sample was placed in an EDTA-containing tube, and 1 drop of EDTA-anticoagulated WB was applied to a test strip. The remaining EDTA-anticoagulated WB sample was centrifuged, and the plasma was harvested and placed on ice. One drop of plasma was applied to a test strip; the remainder of the plasma sample was transported on ice and used for ammonia measurement with a reference laboratory instrument. All samples were tested within 1 hour after sample collection. Results were evaluated to detect significant differences in ammonia concentration. RESULTS Ammonia concentrations did not differ significantly between WB and EDTA-anticoagulated WB and between plasma samples measured with the meter and reference laboratory instrument. However, median ammonia concentration was significantly higher in plasma than in WB or EDTA-anti-coagulated WB. CONCLUSIONS AND CLINICAL RELEVANCE Anticoagulant-free WB was a valid sample for measurement by use of the ammonia meter. Plasma samples had higher ammonia concentrations than did WB samples. Results for each sample type should be interpreted by use of specimen- and method-specific reference intervals.

  11. Technical note: Validation of a handheld meter for measuring β-hydroxybutyrate concentrations in plasma and serum from dairy cows.

    Science.gov (United States)

    Pineda, A; Cardoso, F C

    2015-12-01

    The use of handheld meters for cow-side tests for β-hydroxybutyrate (BHB) concentrations in whole blood has become common. The aim of this study was to compare serum BHB (sBHB) and plasma BHB (pBHB) concentrations analyzed using either a "gold standard" enzymatic laboratory method (LM; Randox Laboratories Ltd., Antrim, UK; cat. no. RB1007) or a handheld meter (PX; Precision Xtra, Abbott Diabetes Care Inc., Alameda, CA). Results from 374 (187 serum and 187 plasma) samples taken from Holstein cows from 11 d before (52 samples) to 5 d after parturition (137 samples) were used for the analysis. Statistical analysis was performed using the MIXED, REG, and LOGISTIC procedures of SAS (v9.4; SAS Institute Inc., Cary, NC). A linear mixed model with repeated measures was fitted for LM and PX. Regression and correlation analyses were completed to estimate the relationship and agreement between the 2 methods. Lin's concordance correlation coefficient (CCC) and Bland-Altman plots were used to evaluate agreement between LM and PX. Cross-validation by randomly splitting the data in model-building and validation sets was performed to estimate and validate the equation that predicted the LM results using PX. Receiver operating characteristic (ROC) curves were used to estimate the sensitivity (Se) and specificity (Sp) of PX at different threshold levels. The CCC was 0.74 for pBHB and 0.68 for sBHB. The 95% confidence interval of agreement of the Bland-Altman plot encompassed 96% of the difference between LM and PX for pBHB and 95% for sBHB. The mean difference for pBHB was -0.50±0.25mmol, and that for sBHB was -0.63±0.41mmol. The highest Se and Sp for PX were achieved when the threshold for ketosis was set to 1.8mmol/L for pBHB and 2.1mmol/L for sBHB. The area under the ROC curve was 0.97 for pBHB and 0.96 for sBHB. The negative bias shown by the Bland-Altman plots suggested that PX yielded higher pBHB and sBHB concentrations than the LM. However, the excellent test

  12. Increased plasma fibronectin concentrations in obesity

    DEFF Research Database (Denmark)

    Andersen, T; Dejgaard, A; Astrup, A

    1987-01-01

    In 23 morbidly obese patients we investigated the influence of a large weight loss (30.6 kg, range 17.5-90.8) on the plasma fibronectin concentrations. Further, changes in plasma fibronectin were related to serum insulin levels and to liver biochemistry. Between the measurements patients had been...... treated with an intermittent very-low-calorie formula diet sufficient in respect to protein, minerals and vitamins. They were investigated in weight-stable states. Before weight reduction, 14 patients (61%, 95% confidence limits 39-80%) had elevated plasma fibronectin levels. Plasma fibronectin decreased...... (medians 1.22 and 0.59 mumol/l before and after weight loss, p less than 0.01) and was after weight loss within the normal range in 14 patients. The change in plasma fibronectin was unassociated with the magnitude of the weight loss as well as with the reduction of overweight. The resulting plasma...

  13. Sequence variation does not confound the measurement of plasma PfHRP2 concentration in African children presenting with severe malaria

    Directory of Open Access Journals (Sweden)

    Ramutton Thiranut

    2012-08-01

    Full Text Available Abstract Background Plasmodium falciparum histidine-rich protein PFHRP2 measurement is used widely for diagnosis, and more recently for severity assessment in falciparum malaria. The Pfhrp2 gene is highly polymorphic, with deletion of the entire gene reported in both laboratory and field isolates. These issues potentially confound the interpretation of PFHRP2 measurements. Methods Studies designed to detect deletion of Pfhrp2 and its paralog Pfhrp3 were undertaken with samples from patients in seven countries contributing to the largest hospital-based severe malaria trial (AQUAMAT. The quantitative relationship between sequence polymorphism and PFHRP2 plasma concentration was examined in samples from selected sites in Mozambique and Tanzania. Results There was no evidence for deletion of either Pfhrp2 or Pfhrp3 in the 77 samples with lowest PFHRP2 plasma concentrations across the seven countries. Pfhrp2 sequence diversity was very high with no haplotypes shared among 66 samples sequenced. There was no correlation between Pfhrp2 sequence length or repeat type and PFHRP2 plasma concentration. Conclusions These findings indicate that sequence polymorphism is not a significant cause of variation in PFHRP2 concentration in plasma samples from African children. This justifies the further development of plasma PFHRP2 concentration as a method for assessing African children who may have severe falciparum malaria. The data also add to the existing evidence base supporting the use of rapid diagnostic tests based on PFHRP2 detection.

  14. Measurement of sorafenib plasma concentration by high-performance liquid chromatography in patients with advanced hepatocellular carcinoma: is it useful the application in clinical practice? A pilot study.

    Science.gov (United States)

    Fucile, Carmen; Marenco, Simona; Bazzica, Marco; Zuccoli, Maria Laura; Lantieri, Francesca; Robbiano, Luigi; Marini, Valeria; Di Gion, Paola; Pieri, Giulia; Stura, Paola; Martelli, Antonietta; Savarino, Vincenzo; Mattioli, Francesca; Picciotto, Antonino

    2015-01-01

    Pharmacokinetics and dose-finding studies on sorafenib were conducted on heterogeneous groups of patients with solid tumors. Portal hypertension, gut motility impairment and altered bile enterohepatic circulation may explain different sorafenib toxicological profile in cirrhotic patients. This study evaluated sorafenib plasma concentration in a homogeneous group of cirrhotic patients with hepatocellular carcinoma (HCC). Sorafenib concentrations were determined by liquid chromatography in 12 consecutive patients. Data have been evaluated by the generalized estimating equations method (p value statistical level was set at α = 0.05). (1) There were not significant differences between sorafenib concentrations in patients who tolerate the full dose versus patients with reduced dose due to toxicity; (2) the average sorafenib concentrations measured 3 h after the morning dosing were lower than those measured 12 h after the evening dosing (p = 0.005); (3) sorafenib concentrations decrease overtime (p < 10(-4)); (4) it has been found an association between the development of severe adverse reactions and sorafenib concentrations (p < 10(-5)). The relationship between dose and concentration of sorafenib in HCC patients is poor and not clinically predictable, confirming the variability both in the maximum tolerated dose and in plasma concentrations. Several factors may influence the pharmacokinetics in patients with liver disease. This may explain the inter-patient variability of concentrations and the lack of differences in concentration at different dosages. It could be interesting to extend the series of HCC patients to enhance information on the kinetics of the drug; furthermore, to establish a threshold of plasma sorafenib concentrations to predict severe adverse reactions would be clinically useful.

  15. Usefulness of saliva for measurement of 3,4-methylenedioxymethamphetamine and its metabolites: correlation with plasma drug concentrations and effect of salivary pH.

    Science.gov (United States)

    Navarro, M; Pichini, S; Farré, M; Ortuño, J; Roset, P N; Segura, J; de la Torre, R

    2001-10-01

    Saliva is an alternative biologic matrix for drugs-of-abuse testing that offers the advantages of noninvasive, rapid, and easy sampling. We studied the excretion profile of 3,4-methylenedioxymethamphetamine (MDMA) and its metabolites in both saliva and plasma, as well the effect of the drug on salivary pH. Saliva and plasma samples were obtained from eight healthy MDMA consumers after ingestion of a single 100-mg dose of the drug. Concentrations of MDMA and its main metabolites, 3,4-methylenedioxyamphetamine (MDA) and 4-hydroxy-3-methoxymethamphetamine (HMMA), in saliva and plasma were measured by gas chromatography-mass spectrometry. Apparent pharmacokinetic parameters for MDMA in saliva were estimated, and the saliva-to-plasma ratio at each time interval was calculated and correlated with salivary pH. MDMA, MDA, and HMMA were detected in saliva. Salivary concentrations of MDMA were 1728.9-6510.6 microg/L and peaked at 1.5 h after drug intake. This was followed by a progressive decrease, with a mean concentration of 126.2 microg/L at 24 h. The saliva-to-plasma ratio was 32.3-1.2, with a peak of 18.1 at 1.5 h after drug administration. Salivary pH seemed to be affected by MDMA administration; pH values decreased by 0.6 units (mean pH values of 6.9 and 6.8 at 1.5 and 4 h after drug administration vs predose pH of 7.4). Measurement of MDMA in saliva is a valuable alternative to determination of plasma drug concentrations in both clinical and toxicologic studies. On-site testing is also facilitated by noninvasive and rapid collection of salivary specimens.

  16. Decreased maternal plasma apelin concentrations in preeclampsia.

    Science.gov (United States)

    Bortoff, Katherine D; Qiu, Chunfang; Runyon, Scott; Williams, Michelle A; Maitra, Rangan

    2012-01-01

    Preeclampsia is a hypertensive disorder that complicates 3-7% of pregnancies. The development of preeclampsia has not been completely elucidated and current therapies are not broadly efficacious. The apelinergic system appears to be involved in hypertensive disorders and experimental studies indicate a role of this system in preeclampsia. Thus, an epidemiological evaluation of apelin protein concentration in plasma was conducted in case-control study of pregnant women. Data and maternal plasma samples were collected from pregnant women with confirmed preeclampsia (n = 76) or normotensive controls (n = 79). Concentrations of apelin peptides were blindly measured using enzyme-linked immunosorbent assay. Data were subjected to statistical analyses. Plasma apelin concentrations, measured at delivery, were lower in preeclampsia cases compared with controls (mean ± standard deviation: 0.66 ± 0.29 vs. 0.78 ± 0.31 ng/mL, p = 0.02). After controlling for confounding by maternal age, smoking status, and pre-pregnancy body mass index, odds of preeclampsia were 48% lower for women with high versus low plasma apelin (≥0.73 vs. preclampsia and other hypertensive maternal disorders.

  17. Plasma fibronectin concentrations in morbidly obese patients

    DEFF Research Database (Denmark)

    Dejgaard, A; Andersen, T; Christoffersen, Pernille Yde

    1984-01-01

    Plasma fibronectin concentrations and liver morphology were investigated in 45 morbidly obese subjects (median overweight 88%) and in 42 normal weight controls, matched for sex and age. A significantly (P less than 0.01) raised plasma fibronectin concentration (median 464 mg/l, range 276-862 mg...... in their liver biopsies (r = 0.33, P less than 0.05). Significantly (P less than 0.05) elevated plasma fibronectin concentrations even in obese subjects without hepatic fatty change indicate that liver fat accumulation is no prerequisite of the obesity-related elevation of plasma fibronectin. Raised plasma...

  18. FK concentrator outdoor measurements

    OpenAIRE

    Hernández Sanz, Maikel; Vilaplana, J., J.; Benitez Gimenez, Pablo; Mohedano,, Rubén; Zamora Herranz, Pablo; Miñano Dominguez, Juan Carlos; Mendes Lopes, Joao

    2013-01-01

    The FK is a two-stage optical concentrator for CPV, composed by a Fresnel lens working as POE and a refractive element working as SOE. Both elements perform Köhler integration, for uniform irradiance purposes. The FK has demonstrated that compares very well with other Fresnel-based concentrator optics. Recent on-sun measurements carried out on an FK mono-module prototype have already shown outstanding results, achieving electrical efficiencies over 34%. Further optimization of optical design ...

  19. Characterization of the analytic performance of an electrochemical point-of-care meter for measuring β-hydroxybutyrate concentration in blood and plasma from periparturient dairy cattle.

    Science.gov (United States)

    Megahed, Ameer A; Hiew, Mark W H; Townsend, Jonathan R; Constable, Peter D

    2017-06-01

    The Precision Xtra electrochemical meter is widely used to measure blood β-hydroxybutyrate concentration (BHBb) in dairy cattle. The meter uses an algorithm optimized for human blood that assumes the HCT in cattle is the same as in people, and that intra-erythrocyte β-hydroxybutyrate (BHBe) and plasma β-hydroxybutyrate (BHBp) concentration are equivalent. The first objective was to characterize the analytic performance of the meter for measuring BHBb and BHBp in dairy cattle. The second objective was to characterize the influence of HCT and sample temperature on BHBp concentration measured by the meter. Blood and plasma samples were obtained from 106 periparturient Holstein cattle and 15 lactating Holstein cows with experimentally induced electrolyte and acid-base imbalances. Meter performance was evaluated using Deming regression and Bland-Altman plots. Multivariable linear regression was used to determine the effect of HCT and sample temperature on BHBb and BHBp concentration, respectively. The meter was linear up to BHB = 3.0 mmol/L as measured by the reference method, equivalent to meter values for BHBb > 4.5 mmol/L and BHBp > 5.2 mmol/L. An increase in HCT resulted in higher BHBb concentration. This result was partially explained by BHBe being much lower than BHBp. Changes in sample temperature caused a linear change in measured BHBp whenever BHBp > 3.0 mmol/L. Meter accuracy was markedly dependent on the BHBe-to-BHBp ratio and consequently the HCT. Therefore, the algorithm used by the meter should be revised when applied to bovine blood for improved accuracy. © 2017 American Society for Veterinary Clinical Pathology.

  20. Measurement of plasma parameters

    International Nuclear Information System (INIS)

    1999-01-01

    The physics issues of the measurements of the plasma properties necessary to provide both the control and science data for achieving the goals of the ITER device are discussed. The assessment of the requirements for these measurements is first discussed, together with priorities that relate to the experimental program. Subsequently, some of the proposed measurement techniques, the plasma diagnostics, are described with particular emphasis on their implementation on ITER and their capability to meet the requirements. A judgement on the present status of the diagnostic program on ITER is provided with some indication of the research and development program necessary to demonstrate viability of techniques or their implementation. (author)

  1. Plasma organochlorine concentrations and bone ultrasound measurements: a cross-sectional study in peri-and postmenopausal Inuit women from Greenland

    Directory of Open Access Journals (Sweden)

    Mulvad Gert

    2006-12-01

    Full Text Available Abstract Background Inuit women are highly exposed through their traditional seafood based diet to organochlorine compounds, some of them displaying endocrine disrupting properties. We hypothesized that this exposure might be related to bone characteristics that are altered in osteoporosis, because hormone deficiency is a known risk factor for the disease. Methods We measured quantitative ultrasound parameters (QUS at the right calcaneum of 153 peri- and postmenopausal Inuit women (49–64 year old from Nuuk, Greenland, and investigated the relation between these parameters and plasma organochlorine concentrations. We used high-resolution gas chromatography with electron capture detection to analyze plasma samples for 14 polychlorinated biphenyls (PCB congeners and 11 chlorinated pesticides and metabolites. We analysed morning urine samples for cadmium, a potential confounder, by atomic absorption spectrometry. We used a validated questionnaire to document dietary and lifestyle habits as well as reproductive and medical histories. Results Concentrations of PCB 153, a surrogate of exposure to most organochlorines present in plasma samples, were inversely correlated to QUS parameters in univariate analyses (p 2 = 0.39; p Conclusion Overall we found little evidence that organochlorines exposure is related to osteoporosis in Greenlandic Inuit women, but the hypothesis that exposure to dioxin-like compounds might be linked to decreased bone quality and osteoporosis deserves further attention.

  2. Primary study on the clinical significance of measurement of epidermal growth factor (EGF) and NPY concentrations in human semen plasma

    International Nuclear Information System (INIS)

    Zhang Jiyun; Ning Yong

    2008-01-01

    Objective: To investigate the difference between the semen plasma contents of EGF and NPY in fertile and non-fertile males with the relevant sperm count and motility. Methods: Semen plasma contents of EGF and NPY were determined with RIA in 110 non-fertile males. Simultaneous semen analysis revealed (1) Group A, n=45, with normal sperm count, (2) Group B, n=34 low sperm count (0-20) x 10 6 /ml and (3) Group C n=31, with aspermia. White blood cell/HPF was examined in all the semen specimens and sperm motile rate and motility were examined in Group A specimens. Results: The semen plasma contents of EGF and NPY in non-fertile males were significantly higher than those in fertile males (P 1 x 10 6 /ml) were significantly lower than those in specimens with more white blood cells (P<0.05). Conclusion: Higher semen plasma contents of EGF and NPY might exert toxic effect on the sperms, contributing to the development of infertility. (authors)

  3. Comparison of Plasma, Saliva, and Hair Levetiracetam Concentrations.

    Science.gov (United States)

    Karaś-Ruszczyk, Katarzyna; Kuczyńska, Julita; Sienkiewicz-Jarosz, Halina; Kurkowska-Jastrzębska, Iwona; Bienkowski, Przemyslaw; Restel, Magdalena; Samochowiec, Jerzy; Mierzejewski, Pawel

    2017-06-01

    Previous findings revealed high correlations between serum/plasma and saliva levetiracetam concentrations, indicating saliva as an alternative matrix for monitoring levetiracetam therapy. Levetiracetam concentration in the hair, which could reflect long-term drug exposure and patients' compliance, has not been systematically tested, as yet. The aim of this study was to determine the correlation between plasma, saliva, and hair levetiracetam concentrations in 47 patients with epilepsy. Plasma, saliva, and hair levetiracetam concentrations were measured by liquid chromatography-tandem mass spectrometry with positive ionization. Levetiracetam saliva and plasma concentrations were highly correlated (r = 0.93). Plasma concentrations were not influenced by sex, age, and other concomitant antiepileptic drugs. Levetiracetam hair concentrations correlated with plasma concentrations (r = 0.36) but not daily dose (mg/kg). Drug hair concentrations were not influenced by hair color or treatment (dyed). The results tend to indicate that saliva may be a reliable alternative to plasma for monitoring levetiracetam concentrations. Levetiracetam can also be detected in human hair.

  4. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    Science.gov (United States)

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  5. Effect of hemodialysis on leflunomide plasma concentrations.

    Science.gov (United States)

    Beaman, Jasmine M; Hackett, L Peter; Luxton, Grant; Illett, Kenneth F

    2002-01-01

    To report on the influence of hemodialysis on the disposition of leflunomide in a woman with end-stage renal disease. A 65-year-old white woman with a history of diabetes, end-stage renal disease, rheumatoid arthritis, vasculitis, and leg ulcers was admitted to the hospital with a flare in the symptoms of joint pain and vasculitis. Prior to admission, she had been treated for rheumatoid arthritis with methotrexate 7.5 mg once a week. Due to adverse effects from methotrexate and continuing painful joints, leflunomide was considered as a therapeutic alternative. A loading dose of 100 mg was followed two days later by a daily dose of 10 mg. The active metabolite of leflunomide (A771726) was measured before and after hemodialysis and between hemodialysis sessions over a period of 80 days. Pre- and post-hemodialysis concentrations were compared for 17 sessions during this time. Based on the initial measured concentrations, the leflunomide dose was increased to 20 mg/d for several weeks before being reduced to 15 mg due to elevated liver enzymes. Although renal pathways are responsible in part for excretion of A771726, the concentrations achieved in this patient at doses of 10-20 mg/d were at the low end of the range reported in the literature. It was shown that pre- and post-hemodialysis concentrations of A771726 did not differ significantly. Thus, the low concentrations of A771726 were not a result of the hemodialysis. Steady-state concentrations of A771726 in plasma were not affected by hemodialysis or renal impairment. Reduction of the dose of leflunomide in patients with chronic renal failure undergoing hemodialysis does not appear to be required.

  6. The protein concentration of blood coagulation factor VII can be measured equally well in plasma and serum

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Overgaard, K; Gram, J

    1995-01-01

    In the Northwick Park Heart Study, the coagulant activity of factor VII (FVII:C) has been identified as a risk marker of ischaemic heart disease. In the fasting state, the protein concentration of FVII (FVII:Ag) might be an even better risk marker, because of the low coefficient of variation...

  7. Plasma Glutamine Concentrations in Liver Failure.

    Directory of Open Access Journals (Sweden)

    Gunnel Helling

    Full Text Available Higher than normal plasma glutamine concentration at admission to an intensive care unit is associated with an unfavorable outcome. Very high plasma glutamine levels are sometimes seen in both acute and chronic liver failure. We aimed to systematically explore the relation between different types of liver failure and plasma glutamine concentrations.Four different groups of patients were studies; chronic liver failure (n = 40, acute on chronic liver failure (n = 20, acute fulminant liver failure (n = 20, and post-hepatectomy liver failure (n = 20. Child-Pugh and Model for End-stage Liver Disease (MELD scores were assessed as indices of liver function. All groups except the chronic liver failure group were followed longitudinally during hospitalisation. Outcomes were recorded up to 48 months after study inclusion.All groups had individuals with very high plasma glutamine concentrations. In the total group of patients (n = 100, severity of liver failure correlated significantly with plasma glutamine concentration, but the correlation was not strong.Liver failure, regardless of severity and course of illness, may be associated with a high plasma glutamine concentration. Further studies are needed to understand whether high glutamine levels should be regarded as a biomarker or as a contributor to symptomatology in liver failure.

  8. Determination of particle concentrations in multitemperature plasmas

    International Nuclear Information System (INIS)

    Richley, E.; Tuma, D.T.

    1982-01-01

    The use of the multitemperature Saha equation (MSE) of Prigogine 1 and Patapov 2 for calculating particle concentrations in plasmas is shown to be an invalid procedure. Errors greater than one order of magnitude in the electron density in high-pressure argon and nitrogen electric arc plasmas can be easily incurred by using the multitemperature Saha equation. The alternative kinetic method for calculating concentrations is shown to be based on firm concepts. Simpliying procedures and computational techniques for calculating concentrations with the kinetic method are illustrated with examples

  9. Plasma catecholamine and serum gastrin concentrations during sham feeding

    DEFF Research Database (Denmark)

    Bekker, Carsten; Andersen, D; Kronborg, O

    1983-01-01

    Plasma adrenaline, plasma noradrenaline and serum gastrin concentrations were measured before and after sham feeding in eight patients with duodenal ulcer and in four normal subjects. No significant change in the concentrations was observed after sham feeding. In three patients with duodenal ulce...... groups. It is concluded that sympathetic nervous activity and serum gastrin concentrations are not influenced by sham feeding in contrast to the influence of insulin hypoglycemia....... an insulin test resulted in a 25-fold rise in plasma adrenaline. The ulcer patients showed significantly higher levels of plasma adrenaline and plasma noradrenaline than the normal subjects both before and after sham feeding, and this difference was probably not caused only by age difference in the two...

  10. Pathogen Inactivated Plasma Concentrated: Preparation and Uses

    Science.gov (United States)

    2004-09-01

    of decontamination, porcine parvovirus (PPV) was selected as a model virus; B19 is the form that infects humans. PPV is an interesting pathogen...ultrasound to cold plasma. The ultrasound generates pure ice crystals, which are then removed to leave concentrated plasma. Testing: Porcine parvovirus ...energy to “burn” any proteins that they encounter. Furthermore, as they react, they also produce multiple other reactive oxygen species (ROS) that are

  11. Plasma concentration of ionized calcium in healthy iguanas.

    Science.gov (United States)

    Dennis, P M; Bennett, R A; Harr, K E; Lock, B A

    2001-08-01

    To measure plasma concentration of ionized calcium in healthy green iguanas. Prospective study. 9 juvenile and 21 (10 male, 11 female) adult iguanas. Blood samples were obtained from each iguana, and plasma calcium, glucose, phosphorus, uric acid, total protein, albumin, globulin, potassium, and ionized calcium concentrations, aspartate transaminase (AST) activity, and pH were measured. Heparinized blood was used for measurement of ionized calcium concentration and blood pH. A CBC was also performed to assess the health of the iguanas. Significant differences were not detected among the 3 groups (juveniles, males, and females) with regard to ionized calcium concentration. Mean ionized calcium concentration measured in blood was 1.47 +/- 0.105 mmol/L. Significant differences were detected between juveniles and adults for values of phosphorus, glucose, total protein, albumin, globulin, and AST activity. Ionized calcium concentration provides a clinical measurement of the physiologically active calcium in circulation. Evaluation of physiologically active calcium in animals with suspected calcium imbalance that have total plasma calcium concentrations within reference range or in gravid animals with considerably increased total plasma calcium concentrations is vital for determining a therapeutic plan. Accurate evaluation of calcium status will provide assistance in the diagnosis of renal disease and seizures and allow for better evaluation of the health status of gravid female iguanas.

  12. Dimethylglycine accumulates in uremia and predicts elevated plasma homocysteine concentrations.

    Science.gov (United States)

    McGregor, D O; Dellow, W J; Lever, M; George, P M; Robson, R A; Chambers, S T

    2001-06-01

    Hyperhomocysteinemia is a risk factor for atherosclerosis that is common in chronic renal failure (CRF), but its cause is unknown. Homocysteine metabolism is linked to betaine-homocysteine methyl transferase (BHMT), a zinc metalloenzyme that converts glycine betaine (GB) to N,N dimethylglycine (DMG). DMG is a known feedback inhibitor of BHMT. We postulated that DMG might accumulate in CRF and contribute to hyperhomocysteinemia by inhibiting BHMT activity. Plasma and urine concentrations of GB and DMG were measured in 33 dialysis patients (15 continuous ambulatory peritoneal dialysis and 18 hemodialysis), 33 patients with CRF, and 33 age-matched controls. Concentrations of fasting plasma total homocysteine (tHcy), red cell and serum folate, vitamins B(6) and B(12), serum zinc, and routine biochemistry were also measured. Groups were compared, and determinants of plasma tHcy were identified by correlations and stepwise linear regression. Plasma DMG increased as renal function declined and was twofold to threefold elevated in dialysis patients. Plasma GB did not differ between groups. The fractional excretion of GB (FE(GB)) was increased tenfold, and FED(MG) was doubled in CRF patients compared with controls. Plasma tHcy correlated positively with plasma DMG, the plasma DMG:GB ratio, plasma creatinine, and FE(GB) and negatively with serum folate, zinc, and plasma GB. In the multiple regression model, only plasma creatinine, plasma DMG, or the DMG:GB ratio was independent predictors of tHcy. DMG accumulates in CRF and independently predicts plasma tHcy concentrations. These findings suggest that reduced BHMT activity is important in the pathogenesis of hyperhomocysteinemia in CRF.

  13. Measurements of total lead concentrations and of lead isotope ratios in whole blood by use of inductively coupled plasma source mass spectrometry

    International Nuclear Information System (INIS)

    Delves, H.T.; Campbell, M.J.

    1988-01-01

    Methods are described for the accurate and precise determination of total lead and its isotopic composition in whole blood using inductively coupled plasma source mass spectrometry (ICP-MS). Sensitivities of up to 3 x 10 6 counts s -1 for 208 Pb at a total lead concentration of 5 μmol l -1 (1 μg ml -1 ) enabled total blood lead levels to be measured in 4 min per sample, with a detection limit of 0.072 μmol l -1 (15 μg l -1 ). The agreement between ICP-MS and atomic absorption spectrometry (AAS) for this analysis was excellent: ICP-MS 0.996 x AAS -0.0165 μmol l -1 ; r 0.994. Isotope ratio measurements required 15 min to achieve the required accuracy and precision both of which were generally better than 0.5% for 206 Pb: 207 Pb and 208 Pb: 206 Pb isotopic lead ratios. The ICP-MS data for these ratios in ten quality control blood specimens has a mean bias relative to isotope dilution mass spectrometry of -0.412% for 206 Pb: 207 Pb ratios and of +0.055% for the 208 Pb: 206 Pb ratios. This level of accuracy and that of the total blood lead measurements is sufficient to permit application of these ICP-MS methods to environmental studies. (author)

  14. Plasma digoxin concentrations and urinary excretion during a 'simpler' regimen of infant digitalization.

    Science.gov (United States)

    Savage, M O; Hibble, A G; Pickering, D

    1975-01-01

    We have measured the plasma concentrations in sick neonates and infants being administered digoxin by a safer regimen. In the presence of normal renal function the plasma concentrations appear to be satisfactory. PMID:1103751

  15. Fetal plasma erythropoietin concentration in severe growth retardation.

    Science.gov (United States)

    Snijders, R J; Abbas, A; Melby, O; Ireland, R M; Nicolaides, K H

    1993-02-01

    The aim of this study was to determine whether hypoxemia induces an increase in plasma erythropoietin concentration in human fetal life and, if so, whether this response stimulates fetal erythropoiesis. The plasma erythropoietin concentration in blood samples from 33 small-for-gestational-age fetuses at 26 to 38 weeks' gestation was measured. Measurements were compared with the reference range for gestation, and associations with PO2, pH, and erythroblast and erythrocyte counts were examined. The mean plasma erythropoietin concentration in the small-for-gestational-age fetuses was significantly increased, and the degree of increase was significantly associated both with fetal acidemia and, more strongly, with fetal erythroblastosis. Erythropoietin production in response to tissue hypoxia occurs from at least 26 weeks' gestation with measurable physiologic effects on erythropoiesis. Furthermore, more accurate assessment of tissue oxygenation may be obtained by measuring the erythroblast count rather than the blood pH.

  16. Meat juice: An alternative matrix for assessing animal health by measuring acute phase proteins. Correlations of pig-MAP and haptoglobin concentrations in pig meat juice and plasma.

    Science.gov (United States)

    Piñeiro, M; Gymnich, S; Knura, S; Piñeiro, C; Petersen, B

    2009-10-01

    Quantification of acute phase proteins (APPs) in blood can be used for monitoring animal health and welfare on farms, and could be also of interest for the detection of diseased animals during the meat inspection process. However serum or plasma is not always available for end-point analysis at slaughter. Meat juice might provide an adequate, alternative matrix that can be easily obtained for post-mortem analysis at abattoirs. The concentrations of pig Major Acute phase Protein (pig-MAP) and haptoglobin, two of the main APPs in pigs, were determined in approximately 300 paired samples of plasma and meat juice from the diaphragm (pars costalis), obtained after freezing and thawing the muscle. APPs concentrations in meat juice were closely correlated to those in plasma (r=0.695 for haptoglobin, r=0.858 for pig-MAP, panimal health in pig production, with implications for food safety and meat quality.

  17. Plasma and skin vitamin E concentrations in canine atopic dermatitis.

    Science.gov (United States)

    Plevnik Kapun, Alja; Salobir, Janez; Levart, Alenka; Tavčar Kalcher, Gabrijela; Nemec Svete, Alenka; Kotnik, Tina

    2013-01-01

    Altered homeostasis of vitamin E has been demonstrated in human atopic dermatitis. Data on plasma and skin vitamin E concentrations in canine atopic dermatitis (CAD) are not available. To determine vitamin E concentrations in plasma and skin of atopic dogs. Vitamin E concentrations in plasma and full-thickness skin biopsies of 15 atopic dogs were related to CAD extent and severity index (CADESI-03) scores and compared to the equivalent concentrations in 17 healthy dogs. Statistically significant differences of measured parameters between the two groups were determined by the nonparametric Mann Whitney U test and correlations between CADESI-03 scores and vitamin E concentrations were evaluated by the Spearman rank test. A value of P vitamin E were significantly lower in atopic dogs than in healthy dogs, with median values of 29.8 and 52.9 μmol/L, respectively. Skin vitamin E values did not differ significantly between patients and healthy controls. The median concentration of skin vitamin E in atopic dogs was higher than that in healthy dogs. No significant correlations were found between CADESI-03 score and plasma vitamin E or skin vitamin E concentrations. Significantly lower plasma vitamin E concentrations in atopic dogs than in healthy controls indicate altered homeostasis of vitamin E in CAD. Further investigation into vitamin E supplementation in CAD is warranted.

  18. Control of exogenous factors affecting plasma homovanillic acid concentration.

    Science.gov (United States)

    Davidson, M; Giordani, A B; Mohs, R C; Mykytyn, V V; Platt, S; Aryan, Z S; Davis, K L

    1987-04-01

    Measurements of plasma homovanillic acid (pHVA) concentrations appear to be a valid research strategy in psychiatric disorders in which a central dopamine (DA) abnormality has been implicated. This study provides guidance about the control of some of the exogenous factors affecting pHVA concentrations. Fasting for 14 hours eliminates the dietary effects on pHVA in healthy human subjects. Changing position, walking for 30 minutes, or smoking two cigarettes has no effect on pHVA concentrations.

  19. Low plasma triiodothyronine concentrations and outcome in preterm infants.

    Science.gov (United States)

    Lucas, A; Rennie, J; Baker, B A; Morley, R

    1988-01-01

    A major association has been found between low plasma triiodothyronine concentrations in preterm neonates and their later developmental outcome. Plasma triiodothyronine concentration was measured longitudinally in 280 preterm infants below 1850 g birth weight. Babies whose lowest recorded concentration was less than 0.3 nmol/l had, at 18 months' corrected age, 8.3 and 7.4 point disadvantages in Bayley mental and motor scales and a 8.6 point disadvantage on the academic scale of Developmental Profile II, even after adjusting for a range of antenatal and neonatal factors known to influence later development. Low concentrations of triiodothyronine were strongly associated with infant mortality, but not after adjusting for the presence of respiratory illness. There was no association between plasma triiodothyronine concentrations and somatic growth up to 18 months, and no association with necrotising enterocolitis or later cerebral palsy. Data on postnatal changes in plasma triiodothyronine concentrations are presented for reference purposes. While cited reference ranges for plasma triiodothyronine concentration appear suitable for well infants above 1500 g birth weight, smaller or ill babies often have very low values for many weeks. Our data are relevant to the debate on endocrine 'replacement' treatment in premature babies. PMID:2461683

  20. Plasma concentrations of endothelin in patients with abnormal vascular reactivity

    International Nuclear Information System (INIS)

    Predel, H.G.; Meyer-Lehnert, H.; Baecker, A.; Stelkens, H.; Kramer, H.J.

    1990-01-01

    We measured circulating concentrations of endothelin in healthy subjects and in patients with abnormal vascular reactivity. Endothelin concentrations were determined by radioimmunoassay after extraction of plasma using Sep-Pak C-18 cartridges in healthy subjects, in patients with diabetes mellitus type I, in patients with mild to moderate essential hypertension and in non-dialyzed patients with stable chronic renal failure. Plasma concentrations were similar in healthy controls, in diabetics and in hypertensive patients averaging 5.0±0.6 pg/ml, 4.7±0.2 pg/ml and 6.5±1.0 pg/ml, respectively. In contrast, plasma concentrations of endothelin were markedly elevated in patients with chronic renal failure averaging 16.6±2.9 pg/ml. No correlations were observed between serum creatinine concentrations ranging from 124 to 850 μmol/l or blood pressure and plasma concentrations of endothelin. Bicycle ergometric exercise in six healthy subjects and an acute modest i.v. saline load of 1,000 ml of 0.45% NaCl administered within 60 min in six patients with mild essential hypertension did not affect plasma concentrations of endothelin

  1. Development of concentric equipotential surfaces in bumpy torus plasma

    International Nuclear Information System (INIS)

    Takasugi, Keiichi; Iguchi, Harukazu; Fujiwara, Masami; Ikegami, Hideo

    1983-01-01

    Radial profiles of the plasma space potential are measured in Nagoya Bumpy Torus (NBT-1) by the use of a heavy ion beam probe. Asymmetric potential profiles owing to toroidal drift are observed in high pressure operation (C-mode). As the pressure is decreased, toroidal plasma is effectively heated (T-mode), poloidal precessional frequency overcomes the electron collision frequency and the equipotential surfaces becomes concentric inside the hot electron ring. (author)

  2. Altering plasma sodium concentration rapidly changes blood pressure during haemodialysis.

    Science.gov (United States)

    Suckling, Rebecca J; Swift, Pauline A; He, Feng J; Markandu, Nirmala D; MacGregor, Graham A

    2013-08-01

    Plasma sodium is increased following each meal containing salt. There is an increasing interest in the effects of plasma sodium concentration, and it has been suggested that it may have direct effects on blood pressure (BP) and possibly influences endothelial function. Experimental increases of plasma sodium concentration rapidly raise BP even when extracellular volume falls. Ten patients with end-stage renal failure established on haemodialysis were studied during the first 2 h of dialysis without fluid removal during this period. They were randomized to receive haemodialysis with (i) dialysate sodium concentration prescribed to 135 mmol/L and (ii) 145 mmol/L in random order in a prospective, single-blinded crossover study. BP measurements and blood samples were taken every 30 min. Pre-dialysis sitting BP was 137/76 ± 7/3 mmHg. Lower dialysate sodium concentration (135 mmol/L) reduced plasma sodium concentration [139.49 ± 0.67 to 135.94 ± 0.52 mmol/L (P area under the curve (AUC) 15823.50 ± 777.15 (mmHg)min] compared with 145 mmol/L [AUC 17018.20 ± 1102.17 (mmHg)min], mean difference 1194.70 ± 488.41 (mmHg)min, P < 0.05. There was a significant positive relationship between change in plasma sodium concentration and change in systolic BP. This direct relationship suggests that a fall of 1 mmol/L in plasma sodium concentration would be associated with a 1.7 mmHg reduction in systolic BP (P < 0.05). The potential mechanism for the increase in BP seen with salt intake may be through small but significant changes in plasma sodium concentration.

  3. Effect of breed on plasma endothelin-1 concentration, plasma renin activity, and serum cortisol concentration in healthy dogs

    DEFF Research Database (Denmark)

    Höglund, K.; Lequarré, A.-S.; Ljungvall, I.

    2016-01-01

    BACKGROUND: There are breed differences in several blood variables in healthy dogs. OBJECTIVE: Investigate breed variation in plasma endothelin-1 (ET-1) concentration, plasma renin activity, and serum cortisol concentration. ANIMALS: Five-hundred and thirty-one healthy dogs of 9 breeds examined...... at 5 centers (2-4 breeds/center). METHODS: Prospective observational study. Circulating concentrations of ET-1 and cortisol, and renin activity, were measured using commercially available assays. Absence of organ-related or systemic disease was ensured by thorough clinical investigations, including...

  4. Plasma procalcitonin concentrations are increased in dogs with sepsis

    Science.gov (United States)

    Goggs, Robert; Milloway, Matthew; Troia, Roberta; Giunti, Massimo

    2018-01-01

    Sepsis, the life-threatening organ dysfunction caused by a dysregulated host response to infection, is difficult to identify and to prognosticate for. In people with sepsis, procalcitonin (PCT) measurement aids diagnosis, enables therapeutic monitoring and improves prognostic accuracy. This study used a commercial canine PCT assay to measure plasma PCT concentrations in dogs with gastric dilatation volvulus (GDV) syndrome and in dogs with sepsis. It was hypothesised that dogs with GDV syndrome and with sepsis have greater plasma PCT concentrations than healthy dogs and that dogs with sepsis have greater PCT concentrations than dogs with GDV syndrome. Before analysing canine plasma samples, the ability of the assay to identify canine PCT, in addition to assay imprecision and the lower limit of detection were established. The assay had low imprecision with coefficients of variation ≤4.5 per cent. The lower limit of detection was 3.4 pg/ml. Plasma PCT concentrations were measured in 20 dogs with sepsis, in 32 dogs with GDV syndrome and in 52 healthy dogs. Median (IQR) PCT concentration in dogs with sepsis 78.7 pg/ml (39.1–164.7) was significantly greater than in healthy dogs 49.8 pg/ml (36.2–63.7) (P=0.019), but there were no significant differences between PCT concentrations in dogs with GDV syndrome and controls (P=0.072) or between dogs with sepsis and GDV syndrome (P=1.000). Dogs with sepsis have significantly increased plasma PCT concentrations compared with healthy dogs, although considerable overlap between these populations was identified. Future investigations should confirm this finding in other populations and evaluate the diagnostic and prognostic value of PCT in dogs with sepsis. PMID:29682292

  5. Reduced plasma concentrations of vitamin B6 and increased ...

    African Journals Online (AJOL)

    Reduced plasma concentrations of vitamin B6 and increased plasma concentrations of the neurotoxin 3-hydroxykynurenine are associated with nodding syndrome: a case control study in Gulu and Amuru districts, Northern Uganda.

  6. Vitamin E plasma concentration in osteoporotic patients

    Directory of Open Access Journals (Sweden)

    Hajimahmoodi M

    2007-06-01

    Full Text Available Background: The cause of osteoporosis is multifactorial and many dietary factors are important in the prevention of this disease. Antioxidants as free radical scavengers may influence osteoporosis by reducing the effects of oxidative stress that may be associated with bone loss. Vitamin E is an important antioxidant that protects polyunsaturated fatty acids (PUFA in cell membranes from oxidation. There are only two studies regarding vitamin E plasma levels in subjects suffering from osteoporosis. The purpose of this study was to investigate the association between plasma vitamin E levels and bone mineral density (BMD in Iranian patients. Methods: Subjects were consecutively recruited between May and September 2005 from among a total of approximately 1000 people referred for instrumental screening for osteoporosis to the Jami Clinic in Tehran. Inclusion criteria for the study group were: a femoral neck T-score of -1 or less, osteopenia, severe osteopenia and osteoporosis. A total of 137 subjects were enrolled. According to their femoral and spinal BMD scores, 54 persons were selected as a control group. The control group consisted of subjects with a femoral neck T-score and spine T-score of -1 or more. In selecting the case group, only the femoral BMD score was used. Plasma vitamin E was measured, after extraction with methanol, by HPLC with UV detection at 280 nm. Methanol, deionized water and butanol (90:4:6 was used as a mobile phase with a C8 column. The flow rate was 1.0 ml. min-1 and the acetate ester of vitamin E was used as an internal standard. Results: The results show no significant difference in plasma vitamin E between the control and case groups, however linear regression analysis does reveal a significant difference between the T-score and plasma vitamin E. Conclusion: Deceleration Femoral bone Density during osteoporosis will be Accelerated with Decrease of Vitamin E Antioxidant level.

  7. Live animal measurements, carcass composition and plasma hormone and metabolite concentrations in male progeny of sires differing in genetic merit for beef production.

    Science.gov (United States)

    Clarke, A M; Drennan, M J; McGee, M; Kenny, D A; Evans, R D; Berry, D P

    2009-07-01

    In genetic improvement programmes for beef cattle, the effect of selecting for a given trait or index on other economically important traits, or their predictors, must be quantified to ensure no deleterious consequential effects go unnoticed. The objective was to compare live animal measurements, carcass composition and plasma hormone and metabolite concentrations of male progeny of sires selected on an economic index in Ireland. This beef carcass index (BCI) is expressed in euros and based on weaning weight, feed intake, carcass weight and carcass conformation and fat scores. The index is used to aid in the genetic comparison of animals for the expected profitability of their progeny at slaughter. A total of 107 progeny from beef sires of high (n = 11) or low (n = 11) genetic merit for the BCI were compared in either a bull (slaughtered at 16 months of age) or steer (slaughtered at 24 months of age) production system, following purchase after weaning (8 months of age) from commercial beef herds. Data were analysed as a 2 × 2 factorial design (two levels of genetic merit by two production systems). Progeny of high BCI sires had heavier carcasses, greater (P animal value (obtained by multiplying carcass weight by carcass value, which was based on the weight of meat in each cut by its commercial value) than progeny of low BCI sires. Regression of progeny performance on sire genetic merit was also undertaken across the entire data set. In steers, the effect of BCI on carcass meat proportion, calculated carcass value (c/kg) and animal value was positive (P carcass fat proportion (P carcass weight followed the same trends as BCI. Muscularity scores, carcass meat proportion and calculated carcass value increased, whereas scanned fat depth, carcass fat and bone proportions decreased with increasing sire EPD for conformation score. The opposite association was observed for sire EPD for fat score. Results from this study show that selection using the BCI had positive

  8. Plasma carnitine concentrations after chronic alcohol intoxication 

    Directory of Open Access Journals (Sweden)

    Alina Kępka

    2013-05-01

    Full Text Available Background: Carnitine transports fatty acids from the cytoplasm to the mitochondrial matrix, where the fatty acids are oxidized. Chronic alcohol consumption reduces the concentration of carnitine and interferes with oxidative processes occurring in the cell.Aim: The assessment of carnitine concentrations in plasma of chronically intoxicated alcohol dependent persons in a 49-day abstinence period.Material/Methods: The study included 31 patients (5 women and 27 men aged from 26 to 60 years (44.6± 8.9 and 32 healthy subjects (15 women and 17 men aged 22-60 years (39.8± 9.4. The patients’ alcohol dependence ranged from 2 to 30 years (13.6± 7.5. Examined subjects consumed 75-700 g of ethanol/day (226.9± 151.5. Plasma concentrations of free and total carnitine were measured three times: at the first (T0, 30th (T30 and 49th (T49 day of hospital detoxification. Free (FC and total (TC carnitine were determined by the spectrophotometric method. Plasma acylcarnitine (AC concentration was calculated from the difference between TC and FC; then the AC/FC ratio was calculated. To determine statistically significant differences for related variables, Student’s t-test was used.Results: At T0, alcoholics had significantly lower concentration of FC and TC (p < 0.05 in plasma, as compared to the control group. In comparison to controls, at T30, plasma TC and FC (p < 0.01 as well as AC (p < 0.001 were reduced. The lowest concentration of TC, FC and AC (p < 0.001was found at T49. The ratio of AC/FC at T0 had a tendency to be higher in alcoholics than in the control group (p = 0.05, whereas at T49 it was significantly lower in alcoholics as compared to the control subjects (p < 0.05.Conclusions: Chronic alcohol intoxication causes a plasma deficiency of carnitine. Forty-nine days of abstinence showed a significant decrease in the concentration of TC, FC and AC. Further research is necessary to clarify whether a low level of plasma carnitine

  9. Effect of estimated glomerular filtration rate on plasma concentrations of B-type natriuretic peptides measured with multiple immunoassays in elderly individuals

    DEFF Research Database (Denmark)

    Schou, M.; Alehagen, U.; Goetze, J.P.

    2009-01-01

    linear regression models. RESULTS: In univariate analyses the effect of a 10% decrease in eGFR on proBNP concentrations was a 15% (95% confidence interval 11% to 18%), 9% (5% to 13%) and 21% (14% to 28%) increase. In multivariate models the effect was a 7% (3% to 11%), 4% (2% to 6%) and 13% (4% to 20....... SETTING: 474 elderly outpatients with suspected heart failure (prevalence 13%) from the primary care. MAIN OUTCOME MEASURES: The effects of eGFR on proBNP, measured with three different immunoassays (Roche Diagnostics, Oslo and Copenhagen), and BNP (Shionogi) concentrations were evaluated by multiple...

  10. Use of refractometry for determination of psittacine plasma protein concentration.

    Science.gov (United States)

    Cray, Carolyn; Rodriguez, Marilyn; Arheart, Kristopher L

    2008-12-01

    Previous studies have demonstrated both poor and good correlation of total protein concentrations in various avian species using refractometry and biuret methodologies. The purpose of the current study was to compare these 2 techniques of total protein determination using plasma samples from several psittacine species and to determine the effect of cholesterol and other solutes on refractometry results. Total protein concentration in heparinized plasma samples without visible lipemia was analyzed by refractometry and an automated biuret method on a dry reagent analyzer (Ortho 250). Cholesterol, glucose, and uric acid concentrations were measured using the same analyzer. Results were compared using Deming regression analysis, Bland-Altman bias plots, and Spearman's rank correlation. Correlation coefficients (r) for total protein results by refractometry and biuret methods were 0.49 in African grey parrots (n=28), 0.77 in Amazon parrots (20), 0.57 in cockatiels (20), 0.73 in cockatoos (36), 0.86 in conures (20), and 0.93 in macaws (38) (Prefractometry in Amazon parrots, conures, and macaws (n=25 each, PRefractometry can be used to accurately measure total protein concentration in nonlipemic plasma samples from some psittacine species. Method and species-specific reference intervals should be used in the interpretation of total protein values.

  11. LDA measurements under plasma conditions

    International Nuclear Information System (INIS)

    Lesinski, J.; Mizera-Lesinska, B.; Fanton, J.C.; Boulos, M.I.

    1979-01-01

    A study was made of the application of Laser Doppler Anemometry (LDA) for the measurement of the fluid and particle velocities under plasma conditions. The flow configuration, is that of a dc plasma jet called the principal jet, in which an alumina powder of a mean particle diameter of 115 μm and a standard deviation of 11.3 μm was injected using a secondary jet. The plasma jet immerged from a 7.1 mm ID nozzle while that of the secondary jet was 2 nm in diameter. The secondary jet was introduced at the nozzle level of the plasma jet directed 90 0 to its axis. Details of the nozzle and the gas flow system are shown in Figure 2

  12. Turbulence measurements in fusion plasmas

    International Nuclear Information System (INIS)

    Conway, G D

    2008-01-01

    Turbulence measurements in magnetically confined toroidal plasmas have a long history and relevance due to the detrimental role of turbulence induced transport on particle, energy, impurity and momentum confinement. The turbulence-the microscopic random fluctuations in particle density, temperature, potential and magnetic field-is generally driven by radial gradients in the plasma density and temperature. The correlation between the turbulence properties and global confinement, via enhanced diffusion, convection and direct conduction, is now well documented. Theory, together with recent measurements, also indicates that non-linear interactions within the turbulence generate large scale zonal flows and geodesic oscillations, which can feed back onto the turbulence and equilibrium profiles creating a complex interdependence. An overview of the current status and understanding of plasma turbulence measurements in the closed flux surface region of magnetic confinement fusion devices is presented, highlighting some recent developments and outstanding problems.

  13. Damping Measurements of Plasma Modes

    Science.gov (United States)

    Anderegg, F.; Affolter, M.; Driscoll, C. F.

    2010-11-01

    For azimuthally symmetric plasma modes in a magnesium ion plasma, confined in a 3 Tesla Penning-Malmberg trap with a density of n ˜10^7cm-3, we measure a damping rate of 2s-1plasma column, alters the frequency of the mode from 16 KHz to 192 KHz. The oscillatory fluid displacement is small compared to the wavelength of the mode; in contrast, the fluid velocity, δvf, can be large compared to v. The real part of the frequency satisfies a linear dispersion relation. In long thin plasmas (α> 10) these modes are Trivelpiece-Gould (TG) modes, and for smaller values of α they are Dubin spheroidal modes. However the damping appears to be non-linear; initially large waves have weaker exponential damping, which is not yet understood. Recent theoryootnotetextM.W. Anderson and T.M. O'Neil, Phys. Plasmas 14, 112110 (2007). calculates the damping of TG modes expected from viscosity due to ion-ion collisions; but the measured damping, while having a similar temperature and density dependence, is about 40 times larger than calculated. This discrepancy might be due to an external damping mechanism.

  14. Plasma magnesium concentration in patients undergoing coronary artery bypass grafting.

    Science.gov (United States)

    Kotlinska-Hasiec, Edyta; Makara-Studzinska, Marta; Czajkowski, Marek; Rzecki, Ziemowit; Olszewski, Krzysztof; Stadnik, Adam; Pilat, Jacek; Rybojad, Beata; Dabrowski, Wojciech

    2017-05-11

    [b]Introduction[/b]. Magnesium (Mg) plays a crucial role in cell physiology and its deficiency may cause many disorders which often require intensive treatment. The aim of this study was to analyse some factors affecting preoperative plasma Mg concentration in patients undergoing coronary artery bypass grafting (CABG). [b]Materials and method[/b]. Adult patients scheduled for elective CABG with cardio-pulmonary bypass (CPB) under general anaesthesia were studied. Plasma Mg concentration was analysed before surgery in accordance with age, domicile, profession, tobacco smoking and preoperative Mg supplementation. Blood samples were obtained from the radial artery just before the administration of anaesthesia. [b]Results. [/b]150 patients were studied. Mean preoperative plasma Mg concentration was 0.93 ± 0.17 mmol/L; mean concentration in patients - 1.02 ± 0.16; preoperative Mg supplementation was significantly higher than in patients without such supplementation. Moreover, intellectual workers supplemented Mg more frequently and had higher plasma Mg concentration than physical workers. Plasma Mg concentration decreases in elderly patients. Patients living in cities, on average, had the highest plasma Mg concentration. Smokers had significantly lower plasma Mg concentration than non-smokers. [b]Conclusions. [/b]1. Preoperative magnesium supplementation increases its plasma concentration. 2. Intellectual workers frequently supplement magnesium. 3. Smoking cigarettes decreases plasma magnesium concentration.

  15. Plasma ascorbic acid concentrations in prevalent patients with end-stage renal disease on hemodialysis.

    Science.gov (United States)

    Sirover, William D; Liu, Yuguan; Logan, Amanda; Hunter, Krystal; Benz, Robert L; Prasad, Deepali; Avila, Jose; Venkatchalam, Thaliga; Weisberg, Lawrence S; Handelman, Garry J

    2015-05-01

    To determine the prevalence of vitamin C (ascorbic acid [AA]) deficiency in patients with end-stage renal disease, the effect of supplemental AA on plasma AA concentrations, and the extrinsic and intrinsic factors that affect plasma AA concentrations in this patient population. In study 1, we compared the effect of hemodialysis (HD) on plasma AA concentrations between patients with low and high pre-HD AA concentrations. In study 2, we analyzed kinetic and nonkinetic factors for their association with increased plasma AA concentrations in patients on maintenance HD. Study 1 was performed in a single outpatient HD clinic in Cherry Hill, New Jersey. Study 2 was performed in 4 outpatient HD clinics in Southern New Jersey. In study 1, we collected plasma samples from 8 adult patients on maintenance HD at various time points around their HD treatment and assayed them for AA concentration. In study 2, we enrolled 203 adult patients and measured pre-HD plasma AA concentrations. We ascertained supplemental AA use and assessed dietary AA intake. In study 1, plasma AA concentrations were compared during the intradialytic and interdialytic period. In study 2, pre-HD plasma AA concentrations were correlated with supplement use and demographic factors. Study 1 showed that over the course of a single HD treatment, the plasma AA concentration decreased by a mean (±standard deviation) of 60% (±6.6). In study 2, the median pre-HD plasma AA concentration was 15.7 μM (interquartile range, 8.7-66.8) in patients who did not take a supplement and 50.6 μM (interquartile range, 25.1-88.8) in patients who did take a supplement (P HD plasma AA concentration ≥30 μM. HD depletes plasma AA concentrations, and AA supplementation allows patients to achieve higher plasma AA concentrations. Copyright © 2015 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  16. Growth hormone concentrations in mammary secretions and plasma of the periparturient bitch and in plasma of the neonate.

    Science.gov (United States)

    Schoenmakers, I; Kooistra, H S; Okkens, A C; Hazewinkel, H A; Bevers, M M; Mol, J A

    1997-01-01

    The presence of growth hormone (GH) in mammary secretions of bitches was investigated in relation to plasma GH concentrations at about the time of parturition and during the first weeks of lactation. Plasma GH concentrations in neonates were measured during the first weeks of lactation, to determine whether GH in maternal milk contributes to plasma concentrations of GH in the neonate. Gastrointestinal uptake of GH was studied by measurement of plasma bovine GH (bGH) concentrations after intragastric administration of bGH. High concentrations of GH were found in the mammary secretions of the bitches, particularly before parturition and in colostrum, exceeding maternal plasma concentration up to 100-1000 times. GH concentrations in milk were not not significantly correlated with GH concentrations in plasma of bitches or neonates. Bovine GH could not be detected in neonatal plasma for 4 h after intragastric administration of bGH. The presence of high concentrations of canine GH (cGH) in ante-partum and colostral mammary secretions is consistent with the progesterone-induced mammary biosynthesis of GH. GH in milk is probably not absorbed from the gastrointestinal tract into the blood circulation of the newborn in its intact form.

  17. Plasma polychlorinated biphenyl concentrations and immune function in postmenopausal women

    International Nuclear Information System (INIS)

    Spector, June T.; De Roos, Anneclaire J.; Ulrich, Cornelia M.; Sheppard, Lianne; Sjoedin, Andreas; Wener, Mark H.; Wood, Brent

    2014-01-01

    Background: Polychlorinated biphenyl (PCB) exposure has been associated with non-Hodgkin lymphoma in several studies, and the immune system is a potential mediator. Objectives: We analyzed associations of plasma PCBs with immune function measures. We hypothesized that higher plasma PCB concentrations are associated with lower immune function cross-sectionally, and that increases in PCB concentrations over a one year period are associated with decreases in immune function. Methods: Plasma PCB concentrations and immune function [natural killer (NK) cell cytotoxicity and PHA-induced T-lymphocyte proliferation (PHA-TLP)] were measured at baseline and one year in 109 postmenopausal overweight women participating in an exercise intervention study in the Seattle, Washington (USA) area. Mixed models, with adjustment for body mass index and other potential confounders, were used to estimate associations of PCBs with immune function cross-sectionally and longitudinally. Results: Associations of PCBs with immune function measures differed across groups of PCBs (e.g., medium- and high-chlorinated and dioxin-like [mono-ortho-substituted]) and by the time frame for the comparison (cross-sectional vs. longitudinal). Higher concentrations of medium- and high-chlorinated PCBs were associated with higher PHA-TLP cross-sectionally but not longitudinally. The mean decrease in 0.5 µg/mL PHA-TLP/50.0 pmol/g-lipid increase in dioxin-like PCBs over one year was 51.6 (95% confidence interval 2.7, 100.5; P=0.039). There was no association between plasma PCBs and NK cytotoxicity. Conclusions: These results do not provide strong evidence of impaired cellular immunity from PCB exposure. Larger longitudinal studies with greater variability in PCB exposures are needed to further examine temporal associations of PCBs with immune function. - Highlights: • Plasma PCBs and immune function were measured in 109 women at baseline and one year. • Immune measures included T lymphocyte proliferation

  18. Plasma polychlorinated biphenyl concentrations and immune function in postmenopausal women

    Energy Technology Data Exchange (ETDEWEB)

    Spector, June T., E-mail: spectj@uw.edu [Department of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, 4225 Roosevelt Way NE, Seattle, WA 98105 (United States); Department of Medicine, School of Medicine, University of Washington, Seattle, WA (United States); De Roos, Anneclaire J., E-mail: ajd335@drexel.edu [Epidemiology Program, Public Health Sciences Division, Fred Hutchinson Cancer Research Center, 1100 Fairview Avenue N, P.O. Box 19024, Seattle, WA 98109 (United States); Department of Epidemiology, School of Public Health, University of Washington, Seattle, WA (United States); Ulrich, Cornelia M., E-mail: neli.ulrich@nct-heidelberg.de [Department of Epidemiology, School of Public Health, University of Washington, Seattle, WA (United States); Cancer Prevention Program, Fred Hutchinson Cancer Research Center, 1100 Fairview Avenue N, P.O. Box 19024, Seattle, WA 98109 (United States); National Center for Tumor Diseases and German Cancer Research Center, Heidelberg (Germany); Sheppard, Lianne, E-mail: sheppard@uw.edu [Department of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, 4225 Roosevelt Way NE, Seattle, WA 98105 (United States); Department of Biostatistics, School of Public Health, University of Washington, Seattle, WA (United States); Sjoedin, Andreas, E-mail: asjodin@cdc.gov [National Center for Environmental Health, CDC, 4770 Buford Highway NE, Atlanta, GA 30341 (United States); Wener, Mark H., E-mail: wener@u.washington.edu [Department of Medicine, School of Medicine, University of Washington, Seattle, WA (United States); Wood, Brent, E-mail: woodbl@u.washington.edu [Department of Medicine, School of Medicine, University of Washington, Seattle, WA (United States); and others

    2014-05-01

    Background: Polychlorinated biphenyl (PCB) exposure has been associated with non-Hodgkin lymphoma in several studies, and the immune system is a potential mediator. Objectives: We analyzed associations of plasma PCBs with immune function measures. We hypothesized that higher plasma PCB concentrations are associated with lower immune function cross-sectionally, and that increases in PCB concentrations over a one year period are associated with decreases in immune function. Methods: Plasma PCB concentrations and immune function [natural killer (NK) cell cytotoxicity and PHA-induced T-lymphocyte proliferation (PHA-TLP)] were measured at baseline and one year in 109 postmenopausal overweight women participating in an exercise intervention study in the Seattle, Washington (USA) area. Mixed models, with adjustment for body mass index and other potential confounders, were used to estimate associations of PCBs with immune function cross-sectionally and longitudinally. Results: Associations of PCBs with immune function measures differed across groups of PCBs (e.g., medium- and high-chlorinated and dioxin-like [mono-ortho-substituted]) and by the time frame for the comparison (cross-sectional vs. longitudinal). Higher concentrations of medium- and high-chlorinated PCBs were associated with higher PHA-TLP cross-sectionally but not longitudinally. The mean decrease in 0.5 µg/mL PHA-TLP/50.0 pmol/g-lipid increase in dioxin-like PCBs over one year was 51.6 (95% confidence interval 2.7, 100.5; P=0.039). There was no association between plasma PCBs and NK cytotoxicity. Conclusions: These results do not provide strong evidence of impaired cellular immunity from PCB exposure. Larger longitudinal studies with greater variability in PCB exposures are needed to further examine temporal associations of PCBs with immune function. - Highlights: • Plasma PCBs and immune function were measured in 109 women at baseline and one year. • Immune measures included T lymphocyte proliferation

  19. Analytic validation and comparison of three commercial immunoassays for measurement of plasma atrial/A-type natriuretic peptide concentration in horses

    DEFF Research Database (Denmark)

    Trachsel, D S; Schwarzwald, C C; Grenacher, B

    2014-01-01

    Measurement of atrial/A-type natriuretic peptide (ANP) concentrations may be of use for assessment of cardiac disease, and reliable data on the analytic performance of available assays are needed. To assess the suitability for clinical use of commercially available ANP assays, intra-assay and inter......-Altman analyses. For all assays, precision was moderate but acceptable and dilution parallelism was good. All assays showed analytic performance similar to other immunoassays used in veterinary medicine. However, the results from the three assays were poorly comparable. Our study highlights the need...

  20. Plasma galanin concentrations in obese, normal weight and anorectic women.

    Science.gov (United States)

    Invitti, C; Brunani, A; Pasqualinotto, L; Dubini, A; Bendinelli, P; Maroni, P; Cavagnini, F

    1995-05-01

    Galanin is believed to play a role in the control of eating behavior. No information is available on its concentrations in the biological fluids in human obesity, and this study aimed to clarify this. We measured plasma galanin and serum insulin levels in 30 obese, 35 normal weight and 11 anorectic women. Mean galanin values were quite similar in obese and control subjects (76.8 +/- 3.20 vs 76.1 +/- 2.33 pg/ml) and only slightly reduced in anorectic patients (67.9 +/- 2.30 pg/ml). Insulin levels were significantly increased and decreased in obese and anorectic patients, respectively, compared to controls. Insulin correlated positively with BMI in the whole group of subjects studied (r = 0.72, P < 0.0001) and in the obese subgroup (r = 0.56, P < 0.02). No correlations could be detected between WH ratio, insulin and galanin concentrations and between galanin and BMI. In conclusion, plasma galanin concentrations appear to be comparable in obese, normal weight and anorectic subjects. This does not exclude a role of galanin in the regulation of eating behavior since variations of the peptide in discrete brain areas may not be detectable in general circulation and peripheral sources of the peptide may contribute to its plasma levels. Also, our data suggest that galanin does not play a major role in the regulation of insulin secretion in humans.

  1. Stress at birth: plasma noradrenaline concentrations of women in labour and in cord blood.

    Science.gov (United States)

    Messow-Zahn, K; Sarafoff, M; Riegel, K P

    1978-03-15

    Radioenzymatically measured plasma noradrenaline concentrations, present at birth in umbilical veins of 19 healthy, 17 acutely asphyxiated, and 9 chronically distressed newborn infants were found to be elevated above maternal values proportional to the degree of distress and to plasma H ion concentrations.

  2. Temperature measurements in thermonuclear plasmas

    International Nuclear Information System (INIS)

    Breton, D.

    1958-01-01

    The temperatures needed to produce thermonuclear reactions are of the order of several million degrees Kelvin. Devising methods for measuring such temperatures has been the subject of research in many countries. In order to present the problem clearly and to demonstrate its importance, the author reviews the various conditions which must be fulfilled in order that reactions may be qualified as thermonuclear. The relationship between the temperature and the cross-section of the reactions is studied, and it is shown that the notion of temperature in the plasmas is complex, which leads to a consideration of the temperature of the ions and that of the electrons. None of the methods for the temperature measurements is completely satisfactory because of the hypotheses which must be made, and which are seldom fulfilled during high-intensity discharges in the plasmas. In practice it is necessary to use several methods simultaneously. (author) [fr

  3. Measurement of air entrainment in plasma jets

    International Nuclear Information System (INIS)

    Fincke, J.R.; Rodriquez, R.; Pentecost, C.G.

    1990-01-01

    The concentration and temperature of air entrained into argon and helium plasma jets has been measured using coherent anti-Stokes Raman spectroscopy (CARS). The argon plasma flow field is characterized by a short region of well behaved laminar flow near the nozzle exit followed by an abrupt transition to turbulence. Once the transition of turbulence occurs, air is rapidly mixed into the jet core. The location of the transition region is determined by the rapid cooling of the jet and the resulting increase in Reynolds number. In contrast, the helium plasma flow field never exceeds a Reynolds number of 200 and remains laminar. The entrainment process in this case is controlled by molecular diffusion rather than turbulent mixing. 9 refs., 5 figs., 1 tab

  4. Risk factors contributing to a low darunavir plasma concentration

    NARCIS (Netherlands)

    Daskapan, Alper; Stienstra, Ymkje; Kosterink, Jos G.W.; Bierman, Wouter F.W.; van der Werf, Tjip S.; Touw, Daan J.; Alffenaar, Jan Willem C.

    Darunavir is an efficacious drug; however, pharmacokinetic variability has been reported. The objective of this study was to find predisposing factors for low darunavir plasma concentrations in patients starting the once- or twice-daily dosage. Darunavir plasma concentrations from January 2010 till

  5. The Influence of a Mouthpiece-Based Topography Measurement Device on Electronic Cigarette User's Plasma Nicotine Concentration, Heart Rate, and Subjective Effects Under Directed and Ad Libitum Use Conditions.

    Science.gov (United States)

    Spindle, Tory R; Hiler, Marzena M; Breland, Alison B; Karaoghlanian, Nareg V; Shihadeh, Alan L; Eissenberg, Thomas

    2017-04-01

    Electronic cigarettes e-cigarettes aerosolize a liquid solution often containing nicotine. e-cigarette nicotine delivery may be influenced by user puffing behaviors ("puff topography"). E-cigarette puff topography can be recorded using mouthpiece-based computerized systems. The present study sought to examine the extent to which these systems influence e-cigarette nicotine delivery and other e-cigarette associated acute effects under ad libitum use conditions. Plasma nicotine concentration, heart rate, and subjective effects were assessed in 29 experienced e-cigarette users using their preferred e-cigarette battery and liquid (≥12mg/mL nicotine) in two sessions differing only by the presence of a mouthpiece-based device. In both sessions, participants completed a directed e-cigarette use bout (10 puffs, 30-s interpuff interval) and a 90-min ad libitum bout. Puff topography was recorded in the session with the topography mouthpiece. Plasma nicotine, heart rate, and subjective effects, aside from "Did the e-cigarette Taste Good?" were independent of topography measurement (higher mean taste ratings were observed in the no topography condition). Mean (SEM) plasma nicotine concentration following the ad libitum bout was 34.3ng/mL (4.9) in the no topography condition and 35.7ng/mL (4.3) in the topography condition. Longer puff durations, longer interpuff intervals, and larger puff volumes were observed in the ad libitum relative to the directed bout. E-cigarette use significantly increased plasma nicotine concentration and heart rate while suppressing abstinence symptoms. These effects did not differ when a topography mouthpiece was present. Future studies using ad libitum e-cigarette use bouts would facilitate understanding of e-cigarette toxicant yield. No prior study has examined whether mouthpiece-based topography recording devices influence e-cigarette associated nicotine delivery, heart rate, or subjective effects under ad libitum conditions or assessed ad

  6. Plasma concentrations of midazolam during continuous subcutaneous administration in palliative care.

    Science.gov (United States)

    Bleasel, M D; Peterson, G M; Dunne, P F

    1994-01-01

    We have investigated the steady-state plasma concentrations of midazolam during continuous subcutaneous administration in palliative care. Using a sensitive gas chromatography with electron capture detector assay, plasma concentrations of midazolam were measured in 11 patients (median age 68 years; range 47-82 years; six females) receiving the drug by continuous subcutaneous infusion (median rate 20 mg/day; range 10-60 mg/day). While not significant, the infusion rate tended to decrease with increasing age of the patient (Spearman's p = -0.51; p = 0.11). The steady-state plasma concentration range was 10-147 ng/ml, with a median of 30 ng/ml. Infusion rates and plasma concentrations of midazolam were correlated (Spearman's p = 0.71; p < 0.05). No other significant relationships were found between plasma concentrations and the variables of age, sex and liver function.

  7. Concentration of platelets and growth factors in platelet-rich plasma from Goettingen minipigs.

    Science.gov (United States)

    Jungbluth, Pascal; Grassmann, Jan-Peter; Thelen, Simon; Wild, Michael; Sager, Martin; Windolf, Joachim; Hakimi, Mohssen

    2014-01-01

    In minipigs little is known about the concentration of growth factors in plasma, despite their major role in several patho-physiological processes such as healing of fractures. This prompted us to study the concentration of platelets and selected growth factors in plasma and platelet-rich plasma (PRP) preparation of sixteen Goettingen minipigs. Platelet concentrations increased significantly in PRP in comparison to native blood plasma. Generally, significant increase in the concentration of all growth factors tested was observed in the PRP in comparison to the corresponding plasma or serum. Five of the plasma samples examined contained detectable levels of bone morphogenic protein 2 (BMP-2) whereas eleven of the plasma or serum samples contained minimal amounts of vascular endothelial growth factor (VEGF) and platelet-derived growth factor (PDGF-bb) respectively. On the other hand variable concentrations of bone morphogenic protein 7 (BMP-7) and transforming growth factor β1 (TGF-β1) were measured in all plasma samples. In contrast, all PRP samples contained significantly increased amounts of growth factors. The level of BMP-2, BMP-7, TGF-β1, VEGF and PDGF-bb increased by 17.6, 1.5, 7.1, 7.2 and 103.3 fold, in comparison to the corresponding non-enriched preparations. Moreover significant positive correlations were found between platelet count and the concentrations of BMP-2 (r=0.62, pplatelet-rich plasma of minipigs which might thus serve as a source of autologous growth factors.

  8. Opioid Concentrations in Oral Fluid and Plasma in Cancer Patients With Pain.

    Science.gov (United States)

    Heiskanen, Tarja; Langel, Kaarina; Gunnar, Teemu; Lillsunde, Pirjo; Kalso, Eija A

    2015-10-01

    Measuring opioid concentrations in pain treatment is warranted in situations where optimal opioid analgesia is difficult to reach. To assess the usefulness of oral fluid (OFL) as an alternative to plasma in opioid concentration monitoring in cancer patients on chronic opioid therapy. We collected OFL and plasma samples from 64 cancer patients on controlled-release (CR) oral morphine, CR oral oxycodone, or transdermal (TD) fentanyl for pain. Samples were obtained on up to five separate days. A total of 213 OFL and plasma samples were evaluable. All patients had detectable amounts of the CR or TD opioid in both plasma and OFL samples. The plasma concentrations of oxycodone and fentanyl (determination coefficient R(2) = 0.628 and 0.700, respectively), but not morphine (R(2) = 0.292), were moderately well correlated to the daily opioid doses. In contrast to morphine and fentanyl (mean OFL/plasma ratio 2.0 and 3.0, respectively), the OFL oxycodone concentrations were significantly higher than the respective plasma concentrations (mean OFL/plasma ratio 14.9). An active transporter could explain the much higher OFL vs. plasma concentrations of oxycodone compared with morphine and fentanyl. OFL analysis is well suited for detecting the studied opioids. For morphine and fentanyl, an approximation of the plasma opioid concentrations is obtainable, whereas for oxycodone, the OFL/plasma concentration relationship is too variable for reliable approximation results. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  9. Lutein Supplementation Increases Breast Milk and Plasma Lutein Concentrations in Lactating Women and Infant Plasma Concentrations but Does Not Affect Other Carotenoids123

    Science.gov (United States)

    Sherry, Christina L.; Oliver, Jeffery S.; Renzi, Lisa M.; Marriage, Barbara J.

    2014-01-01

    Lutein is a carotenoid that varies in breast milk depending on maternal intake. Data are lacking with regard to the effect of dietary lutein supplementation on breast milk lutein concentration during lactation and subsequent plasma lutein concentration in breast-fed infants. This study was conducted to determine the impact of lutein supplementation in the breast milk and plasma of lactating women and in the plasma of breast-fed infants 2–3 mo postpartum. Lutein is the dominant carotenoid in the infant brain and the major carotenoid found in the retina of the eye. Eighty-nine lactating women 4–6 wk postpartum were randomly assigned to be administered either 0 mg/d of lutein (placebo), 6 mg/d of lutein (low-dose), or 12 mg/d of lutein (high-dose). The supplements were consumed for 6 wk while mothers followed their usual diets. Breast milk carotenoids were measured weekly by HPLC, and maternal plasma carotenoid concentrations were measured at the beginning and end of the study. Infant plasma carotenoid concentrations were assessed at the end of the study. No significant differences were found between dietary lutein + zeaxanthin intake and carotenoid concentrations in breast milk and plasma or body mass index at baseline. Total lutein + zeaxanthin concentrations were greater in the low- and high-dose–supplemented groups than in the placebo group in breast milk (140% and 250%, respectively; P Lutein supplementation did not affect other carotenoids in lactating women or their infants. Lactating women are highly responsive to lutein supplementation, which affects plasma lutein concentrations in the infant. This trial was registered at clinicaltrials.gov as NCT01747668. PMID:24899160

  10. Lutein supplementation increases breast milk and plasma lutein concentrations in lactating women and infant plasma concentrations but does not affect other carotenoids.

    Science.gov (United States)

    Sherry, Christina L; Oliver, Jeffery S; Renzi, Lisa M; Marriage, Barbara J

    2014-08-01

    Lutein is a carotenoid that varies in breast milk depending on maternal intake. Data are lacking with regard to the effect of dietary lutein supplementation on breast milk lutein concentration during lactation and subsequent plasma lutein concentration in breast-fed infants. This study was conducted to determine the impact of lutein supplementation in the breast milk and plasma of lactating women and in the plasma of breast-fed infants 2-3 mo postpartum. Lutein is the dominant carotenoid in the infant brain and the major carotenoid found in the retina of the eye. Eighty-nine lactating women 4-6 wk postpartum were randomly assigned to be administered either 0 mg/d of lutein (placebo), 6 mg/d of lutein (low-dose), or 12 mg/d of lutein (high-dose). The supplements were consumed for 6 wk while mothers followed their usual diets. Breast milk carotenoids were measured weekly by HPLC, and maternal plasma carotenoid concentrations were measured at the beginning and end of the study. Infant plasma carotenoid concentrations were assessed at the end of the study. No significant differences were found between dietary lutein + zeaxanthin intake and carotenoid concentrations in breast milk and plasma or body mass index at baseline. Total lutein + zeaxanthin concentrations were greater in the low- and high-dose-supplemented groups than in the placebo group in breast milk (140% and 250%, respectively; P Lutein supplementation did not affect other carotenoids in lactating women or their infants. Lactating women are highly responsive to lutein supplementation, which affects plasma lutein concentrations in the infant. This trial was registered at clinicaltrials.gov as NCT01747668. © 2014 American Society for Nutrition.

  11. effects of artemether on the plasma and urine concentrations of ...

    African Journals Online (AJOL)

    Dr Komolafe

    2011-05-16

    May 16, 2011 ... degeneration of the renal tissue of rats, inability of the damaged kidneys to concentrate urine, which manifested as excessive water loss and electrolyte depletion. Key words: Artemether, electrolytes in plasma, urine concentrations, rats. INTRODUCTION. Artemether, one of the derivatives of artemisinin, is.

  12. Negative symptoms in nondeficit syndrome respond to neuroleptic treatment with changes in plasma homovanillic acid concentrations.

    Science.gov (United States)

    Suzuki, E; Kanba, S; Koshikawa, H; Nibuya, M; Yagi, G; Asai, M

    1996-05-01

    Deficit syndrome (DS) in schizophrenia is characterized by serious, chronic, and primary negative symptoms. We investigated differences in response to neuroleptic treatment between 8 DS patients and 6 nondeficit syndrome (NDS) patients who had the selective dopamine-D2 receptor blocker bromperidol added to their neuroleptic regimens. First, 9 mg/d was administered for 4 weeks, followed by 18 mg/d for another 4 weeks. Plasma homovanillic acid (pHVA) and plasma bromperidol concentrations were measured, and psychiatric symptoms were scored. In the NDS patients, both positive and negative symptoms improved. However, only the positive symptom scores changed in the DS patients. On day 4, pHVA concentrations of the NDS patients alone were significantly elevated. Plasma bromperidol concentrations did not differ between the groups. These results suggest that bromperidol exerts different effects on negative symptoms and pHVA concentrations between NDS and DS patients, effects that are unrelated to plasma bromperidol concentrations.

  13. Plasma 8-iso-Prostaglandin F2α concentrations and outcomes after acute intracerebral hemorrhage.

    Science.gov (United States)

    Du, Quan; Yu, Wen-Hua; Dong, Xiao-Qiao; Yang, Ding-Bo; Shen, Yong-Feng; Wang, Hao; Jiang, Li; Du, Yuan-Feng; Zhang, Zu-Yong; Zhu, Qiang; Che, Zhi-Hao; Liu, Qun-Jie

    2014-11-01

    Higher plasma 8-iso-Prostaglandin F2α concentrations have been associated with poor outcome of severe traumatic brain injury. We further investigated the relationships between plasma 8-iso-Prostaglandin F2α concentrations and clinical outcomes in patients with acute intracerebral hemorrhage. Plasma 8-iso-Prostaglandin F2α concentrations of 128 consecutive patients and 128 sex- and gender-matched healthy subjects were measured by enzyme-linked immunosorbent assay. We assessed their relationships with disease severity and clinical outcomes including 1-week mortality, 6-month mortality and unfavorable outcome (modified Rankin Scale score>2). Plasma 8-iso-Prostaglandin F2α concentrations were substantially higher in patients than in healthy controls. Plasma 8-iso-Prostaglandin F2α concentrations were positively associated with National Institutes of Health Stroke Scale (NIHSS) scores and hematoma volume using a multivariate linear regression. It emerged as an independent predictor for clinical outcomes of patients using a forward stepwise logistic regression. ROC curves identified the predictive values of plasma 8-iso-Prostaglandin F2α concentrations, and found its predictive value was similar to NIHSS scores and hematoma volumes. However, it just numerically added the predictive values of NIHSS score and hematoma volume. Increased plasma 8-iso-Prostaglandin F2α concentrations are associated with disease severity and clinical outcome after acute intracerebral hemorrhage. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Measuring the Plasma Density of a Ferroelectric Plasma Source in an Expanding Plasma

    International Nuclear Information System (INIS)

    Dunaevsky, A.; Fisch, N.J.

    2003-01-01

    The initial density and electron temperature at the surface of a ferroelectric plasma source were deduced from floating probe measurements in an expanding plasma. The method exploits negative charging of the floating probe capacitance by fast flows before the expanding plasma reaches the probe. The temporal profiles of the plasma density can be obtained from the voltage traces of the discharge of the charged probe capacitance by the ion current from the expanding plasma. The temporal profiles of the plasma density, at two different distances from the surface of the ferroelectric plasma source, could be further fitted by using the density profiles for the expanding plasma. This gives the initial values of the plasma density and electron temperature at the surface. The method could be useful for any pulsed discharge, which is accompanied by considerable electromagnetic noise, if the initial plasma parameters might be deduced from measurements in expanding plasma

  15. Radioimmunoassay of plasma myoglobin concentrations in normal persons

    Energy Technology Data Exchange (ETDEWEB)

    Milanov, S.; Milkov, V. (Meditsinska Akademiya, Sofia (Bulgaria). Nauchen Inst. po Rentgenologiya i Radiobiologiya)

    1982-01-01

    Plasma myoglobin concentrations by radioimmunoassay in 53 normal persons (29 women and 24 men) with ages ranging from 19 to 76 years. The average values for myoglobin concentrations in the plasma of 29 women, aged 19 to 76 years, are 4a.09 +- 4.51 ng/ml, while in 24 healthy men, aged 20 to 74 years, they are 54.39 +-4.68 ng/ml. The obtained results for the plasma myoglobin level in men are higher than the ones recorded in women at statistical significance p<0.05. In the group under study the plasma myoglobin values disclose also age-related differences, although lacking statistical significance (p>0.10).

  16. Plasma fibronectin concentrations in patients with liver diseases

    DEFF Research Database (Denmark)

    Gluud, C; Dejgaard, A; Clemmensen, I

    1983-01-01

    age- and sex-matched healthy controls in patients with chronic persistent or chronic active hepatitis (n = 7), primary biliary cirrhosis (n = 8), alcoholic fatty liver (n = 9), alcoholic hepatitis (n = 10), and alcoholic cirrhosis (n = 16). Patients with acute viral hepatitis (type A (n = 2); type B...... (n = 7); type non A, non B (n = 1] had significantly (P less than 0.01) raised plasma fibronectin concentrations (median 506 mg/l (range 339-804] compared to controls (median 399 mg/l (range 304-462]. Morbidly obese patients with fatty liver (n = 11) had significantly (P less than 0.001) raised......Plasma, obtained just prior to diagnostic liver biopsy in 71 patients with various liver diseases, was examined by electroimmunoassay using immunoglobulin against human fibronectin and purified plasma fibronectin as standard. The plasma fibronectin concentration was not significantly different from...

  17. Measurement of heavy metals by means of a plasma-assisted method

    International Nuclear Information System (INIS)

    Hernberg, R.; Haeyrinen, V.; Oikari, R.

    1995-01-01

    The plasma-assisted measuring device for on-line measurement of alkali metal concentrations in pressurised processes, which has been developed in the Laboratory, will be further developed to provide for simultaneous measurement of heavy metal concentrations. (author)

  18. Concentration of perfluorinated compounds and cotinine in human foetal organs, placenta, and maternal plasma

    DEFF Research Database (Denmark)

    Mamsen, Linn Salto; Jönsson, Bo A.G.; Lindh, Christian H.

    2017-01-01

    levels. Foetal exposure has previously been estimated from umbilical cord plasma, but the actual concentration in foetal organs has never been measured. Objectives The concentrations of 5 PFASs and cotinine – the primary metabolite of nicotine – were measured in human foetuses, placentas, and maternal...... plasma to evaluate to what extent these compounds were transferred from mother to foetus and to determine if the PFAS concentrations were associated with maternal cigarette smoking. Methods Thirty-nine Danish women who underwent legal termination of pregnancy before gestational week 12 were included; 24...... ratio for all five PFASs and cotinine. Smokers presented 99 ng/g cotinine in plasma, 108 ng/g in placenta, and 61 ng/g in foetal organs. No correlation between the maternal cotinine concentrations and PFAS concentrations was found. Conclusions PFASs were transferred from mother to foetus, however...

  19. Computed exercise plasma lactate concentrations: A conversion formula

    Directory of Open Access Journals (Sweden)

    Lia Bally

    2016-04-01

    Full Text Available Objectives: Blood lactate measurements are common as a marker of skeletal muscle metabolism in sport medicine. Due to the close equilibrium between the extracellular and intramyocellular space, plasma lactate is a more accurate estimate of muscle lactate. However, whole blood-based lactate measurements are more convenient in field use. The purpose of this investigation was therefore (1 to establish a plasma-converting lactate formula for field use, and (2 to validate the computed plasma lactate levels by comparison to a laboratory standard method. Design and methods: A total of 91 venous samples were taken from 6 individuals with type 1 diabetes during resting and exercise conditions and assessed for whole blood and plasma lactate using the YSI 2300 analyzer. A linear model was applied to establish a formula for converting whole blood lactate to plasma lactate. The validity of computed plasma lactate values was assessed by comparison to a laboratory standard method. Results: Whole blood YSI lactate could be converted to plasma YSI values (slope 1.66, intercept 0.12 for samples with normal hematocrit. Computed plasma levels compared to values determined by the laboratory standard method using Passing-Bablok regression yielded a slope of 1.03 (95%CI:0.99:1.08 with an intercept of -0.11 (95%CI:-0.18:-0.06. Conclusions: Whole blood YSI lactate values can be reliably converted into plasma values which are in line with laboratory determined plasma measurements. Keywords: Lactate, Plasma vs whole-blood, Hematocrit, Enzyme electrodes, Sample treatment

  20. A method for estimation of plasma albumin concentration from the buffering properties of whole blood

    DEFF Research Database (Denmark)

    Rees, Stephen Edward; Diemer, Tue; Kristensen, Søren Risom

    2012-01-01

    measurements of acid-base and oxygenation status. This article presents and evaluates a new method for doing so. MATERIALS AND METHODS: The mathematical method for estimating plasma albumin concentration is described. To evaluate the method at numerous albumin concentrations, blood from 19 healthy subjects......PURPOSE: Hypoalbuminemia is strongly associated with poor clinical outcome. Albumin is usually measured at the central laboratory rather than point of care, but in principle, information exists in the buffering properties of whole blood to estimate plasma albumin concentration from point of care...

  1. Changes in plasma potassium concentration during carbon dioxide pneumoperitoneum

    DEFF Research Database (Denmark)

    Perner, A; Bugge, K; Lyng, K M

    1999-01-01

    Hyperkalaemia with ECG changes had been noted during prolonged carbon dioxide pneumoperitoneum in pigs. We have compared plasma potassium concentrations during surgery in 11 patients allocated randomly to undergo either laparoscopic or open appendectomy and in another 17 patients allocated randomly...... to either carbon dioxide pneumoperitoneum or abdominal wall lifting for laparoscopic colectomy. Despite an increasing metabolic acidosis, prolonged carbon dioxide pneumoperitoneum resulted in only a slight increase in plasma potassium concentrations, which was both statistically and clinically insignificant....... Thus hyperkalaemia is unlikely to develop in patients with normal renal function undergoing carbon dioxide pneumoperitoneum for laparoscopic surgery....

  2. Isoniazid concentrations in hair and plasma area-under-the-curve exposure among children with tuberculosis.

    Directory of Open Access Journals (Sweden)

    Vidya Mave

    Full Text Available We measured hair and plasma concentrations of isoniazid among sixteen children with tuberculosis who underwent personal or video-assisted directly observed therapy and thus had 100% adherence. This study therefore defined typical isoniazid exposure parameters after two months of treatment among fully-adherent patients in both hair and plasma (plasma area under the concentration-time curve, AUC, estimated using pharmacokinetic data collected 0, 2, 4, and 6 hours after drug administration. We found that INH levels in hair among highly-adherent individuals did not correlate well with plasma AUC or trough concentrations, suggesting that each measure may provide incremental and complementary information regarding drug exposure in the context of TB treatment.

  3. Variable aromatase inhibitor plasma concentrations do not correlate with circulating estrogen concentrations in post-menopausal breast cancer patients.

    Science.gov (United States)

    Hertz, Daniel L; Speth, Kelly A; Kidwell, Kelley M; Gersch, Christina L; Desta, Zeruesenay; Storniolo, Anna Maria; Stearns, Vered; Skaar, Todd C; Hayes, Daniel F; Henry, N Lynn; Rae, James M

    2017-10-01

    The aromatase inhibitors (AI) exemestane (EXE), letrozole (LET), and anastrozole suppress estrogen biosynthesis, and are effective treatments for estrogen receptor (ER)-positive breast cancer. Prior work suggests that anastrozole blood concentrations are associated with the magnitude of estrogen suppression. The objective of this study was to determine whether the magnitude of estrogen suppression, as determined by plasma estradiol (E2) concentrations, in EXE or LET treated patients is associated with plasma AI concentrations. Five hundred post-menopausal women with ER-positive breast cancer were enrolled in the prospective Exemestane and Letrozole Pharmacogenetic (ELPh) Study conducted by the COnsortium on BReast cancer phArmacogomics (COBRA) and randomly assigned to either drug. Estrogen concentrations were measured at baseline and after 3 months of AI treatment and drug concentrations were measured after 1 or 3 months. EXE or LET concentrations were compared with 3-month E2 concentration or the change from baseline to 3 months using several complementary statistical procedures. Four-hundred patients with on-treatment E2 and AI concentrations were evaluable (EXE n = 200, LET n = 200). Thirty (7.6%) patients (EXE n = 13, LET n = 17) had 3-month E2 concentrations above the lower limit of quantification (LLOQ) (median: 4.75; range: 1.42-63.8 pg/mL). EXE and LET concentrations were not associated with on-treatment E2 concentrations or changes in E2 concentrations from baseline (all p > 0.05). Steady-state plasma AI concentrations do not explain variability in E2 suppression in post-menopausal women receiving EXE or LET therapy, in contrast with prior evidence in anastrozole treated patients.

  4. Effect of Diuresis on Plasma Renin Activity and Aldosterone Concentration in Normal and Toxemic Pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Sung, H. K.; Lee, H. S.; Cho, S. S.; Koh, J. H.; Lee, J. K.; Kim, H. S. [Korea Atomic Emergy Research Institute, Seoul (Korea, Republic of)

    1973-03-15

    The changes of plasma renin activity, aldosterone concentration, serum sodium, and potassium levels were studied before and after the water loading followed by diuretics injection. The materials were: 13 non-, 11 normal-, and 11 toxemic pregnancy cases. The plasma renin activity and aldosterone concentration of the cord and postpartum blood were also measured. Following were the results: 1. The plasma renin activity was elevated significantly in normal pregnancy, and slightly in toxemic pregnancy. The serum sodium levels were decreased in pregnancy. 2. The plasma aldosterone concentration was slightly decreased in normal pregnancy, and slightly increased in toxemic pregnancy, however, statistically insignificant. 3. The plasma renin activity of the cord and postpartum blood were lower than those of pregnancy cases. 4. The changes of plasma renin activity after the diuretic administration showed an initial increase, which recovered within 2 hours. These changes were the least in normal pregnancy, and the most in toxemic pregnancy. 5. The changes of plasma aldosterone concentration after the diuretic administration were similar to those of plasma renin activity, although the variations were not so wide.

  5. Effect of Diuresis on Plasma Renin Activity and Aldosterone Concentration in Normal and Toxemic Pregnancy

    International Nuclear Information System (INIS)

    Sung, H. K.; Lee, H. S.; Cho, S. S.; Koh, J. H.; Lee, J. K.; Kim, H. S.

    1973-01-01

    The changes of plasma renin activity, aldosterone concentration, serum sodium, and potassium levels were studied before and after the water loading followed by diuretics injection. The materials were: 13 non-, 11 normal-, and 11 toxemic pregnancy cases. The plasma renin activity and aldosterone concentration of the cord and postpartum blood were also measured. Following were the results: 1. The plasma renin activity was elevated significantly in normal pregnancy, and slightly in toxemic pregnancy. The serum sodium levels were decreased in pregnancy. 2. The plasma aldosterone concentration was slightly decreased in normal pregnancy, and slightly increased in toxemic pregnancy, however, statistically insignificant. 3. The plasma renin activity of the cord and postpartum blood were lower than those of pregnancy cases. 4. The changes of plasma renin activity after the diuretic administration showed an initial increase, which recovered within 2 hours. These changes were the least in normal pregnancy, and the most in toxemic pregnancy. 5. The changes of plasma aldosterone concentration after the diuretic administration were similar to those of plasma renin activity, although the variations were not so wide.

  6. Measurement of toroidal plasma current in RF heated helical plasmas

    International Nuclear Information System (INIS)

    Besshou, Sakae

    1993-01-01

    This report describes the measurement of toroidal plasma current by a semiflexible Rogowski coil in a helical vacuum chamber. A Rogowski coil measures the toroidal plasma current with a resolution of 0.1 kA, frequency range of up to 1 kHz and sensitivity of 6.5 x 10 -9 V · s/A. We measured the spontaneous toroidal plasma current (from -1.2 to +1.2 kA) under electron cyclotron resonance heating at 0.94 T toroidal field in the Heliotron-E device. We found that the measured direction of toroidal plasma current changes its sign as in the predicted behavior of a neoclassical diffusion-driven bootstrap current, depending on the horizontal position of the plasma column. We explain the observed plasma currents in terms of the compound phenomenon of an ohmic current and a neoclassical diffusion-driven current. The magnitude of the neoclassical current component is smaller than the value predicted by a collisionless neoclassical theory. (author)

  7. Choline concentrations are lower in postnatal plasma of preterm infants than in cord plasma.

    Science.gov (United States)

    Bernhard, Wolfgang; Raith, Marco; Kunze, Rebecca; Koch, Vera; Heni, Martin; Maas, Christoph; Abele, Harald; Poets, Christian F; Franz, Axel R

    2015-08-01

    Choline is essential to human development, particularly of the brain in the form of phosphatidylcholine, sphingomyelin and acetylcholine, for bile and lipoprotein formation, and as a methyl group donator. Choline is actively transported into the fetus, and maternal supply correlates with cognitive outcome. Interruption of placental supply may therefore impair choline homeostasis in preterm infants. Determination of postnatal plasma concentrations of choline and its derivatives betaine and dimethylglycine (DMG) in preterm infants compared to cord and maternal blood matched for postmenstrual age (PMA). We collected plasma of very low-birth-weight infants undergoing neonatal intensive care (n = 162), cord plasma of term and preterm infants (n = 176, 24-42-week PMA), serum of parturients (n = 36), and plasma of healthy premenopausal women (n = 40). Target metabolites were analyzed with tandem mass spectrometry and reported as median (25th/75th percentiles). Cord plasma choline concentration was 41.4 (31.8-51.2) µmol/L and inversely correlated with PMA. In term but not in preterm infants, cord plasma choline was lower in girls than in boys. Prenatal glucocorticoid treatment did not affect choline levels in cord plasma, whereas betaine was decreased and DMG increased. In parturients and non-pregnant women, choline concentrations were 14.1 (10.3-16.9) and 8.8 (5.7-11.2) µmol/L, respectively, whereas betaine was lowest in parturients. After delivery, preterm infant plasma choline decreased to 20.8 (16.0-27.6) µmol/L within 48 h. Betaine and DMG correlated with plasma choline in all groups. In preterm infants, plasma choline decreases to 50 % of cord plasma concentrations, reflecting choline undernourishment and postnatal metabolic adaptation, and potentially contributing to impaired outcome.

  8. Relationship between the concentrations of plasma phospholipid stearic acid and plasma lipoprotein lipids in healthy men.

    Science.gov (United States)

    Li, D

    2001-01-01

    This study investigated the correlation between the plasma phospholipid (PL) saturated fatty acid (SFA) concentration (as a surrogate marker of SFA intake) and plasma lipid and lipoprotein lipid concentrations in 139 healthy Australian men aged 20-55 years old with widely varying intakes of saturated fat (vegans, n=18; ovolacto vegetarians, n=43; moderate meat eaters, n=60; high meat eaters, n=18). Both the ovolacto vegetarian and vegan groups demonstrated significant decreases in plasma total cholesterol (TC), low-density-lipoprotein cholesterol (LDL-C) and triacylglycerol concentrations compared with both the high-meat-eater and moderate-meat-eater groups. Total SFA and individual SFA [palmitic acid (16:0), stearic acid (18:0) and arachidic acid (20:0)] in the plasma PL were significantly lower in both the ovolacto vegetarian and vegan groups than in both the high- and moderate-meat-eater groups, while myristic acid (14:0) was significantly lower in the vegans than in the high-meat-eaters. Bivariate analysis of the results showed that the plasma PL stearic acid concentration was strongly positively correlated with plasma TC (P<0.0001), LDL-C (P<0.0001) and triacylglycerol (P<0.0001), with r(2) values of 0.655, 0.518 and 0.43 respectively. In multiple linear regression, after controlling for potential confounding factors (such as exercise, dietary group, age, body mass index, plasma PL myristic acid, palmitic acid and arachidic acid, and dietary total fat, saturated fat, cholesterol, carbohydrate and fibre intake), the plasma PL stearic acid concentration was still strongly positively correlated with plasma TC (P<0.0001) and LDL-C (P=0.006) concentrations. Based on the present data, it would seem appropriate for the population to reduce their dietary total SFA intake rather than to replace other SFA with stearic acid.

  9. Effect of intravenous injection of galanin on plasma concentrations ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-10-06

    Oct 6, 2008 ... The goal of this study was to determine whether intravenously galanin injection effect on plasma concentrations of growth hormone (GH), thyroxine (T4), triiodothyronine (T3) and milk production in the. Saanen goats. Fifteen Saanen goats were randomly divided into 5 groups (n = 3 in each group). Each.

  10. Effect of serotonin infusions on the mean plasma concentrations of ...

    African Journals Online (AJOL)

    Milk samples were assayed for protein, fat and lactose constituents. The daily amounts of milk were determined throughout the experiment. Infusions of 1 ng 5HT did not change the plasma concentrations of the T3, T4 and GH throughout the experiment period. Infusions of 4 and 8 ng 5HT significantly (p<0.01) increased the ...

  11. Recalculation of measured fuel nuclide concentrations

    International Nuclear Information System (INIS)

    Moeller, W.

    1984-01-01

    The concentrations and concentration ratios of heavy fuel nuclides determined in the Central Institute for Nuclear Research Rossendorf on the basis of destructive burnup measurements are compared with the results of microburnup calculations. The possibility is discussed to improve the results by taking into account the spectral characteristics at the positions of the measuring samples. (author)

  12. Unfiltered coffee increases plasma homocysteine concentrations in healthy volunteers: a randomized trial

    NARCIS (Netherlands)

    Grubben, M.J.; Boers, G.H.; Blom, H.J.; Broekhuizen, R.; Jong, de R.; Rijt, van L.; Katan, M.B.

    2000-01-01

    Background: An elevated plasma homocysteine concentration is a putative risk factor for cardiovascular disease. Observational studies have reported an association between coffee consumption and plasma homocysteine concentrations. Objective: We studied the effect of coffee consumption on plasma

  13. Unfiltered coffee increases plasma homocysteine concentrations in healthy volunteers: a randomized trial

    NARCIS (Netherlands)

    Grubben, M. J.; Boers, G. H.; Blom, H. J.; Broekhuizen, R.; de Jong, R.; van Rijt, L.; de Ruijter, E.; Swinkels, D. W.; Nagengast, F. M.; Katan, M. B.

    2000-01-01

    An elevated plasma homocysteine concentration is a putative risk factor for cardiovascular disease. Observational studies have reported an association between coffee consumption and plasma homocysteine concentrations. We studied the effect of coffee consumption on plasma homocysteine in a crossover

  14. Reduced plasma aldosterone concentrations in randomly selected patients with insulin-dependent diabetes mellitus.

    LENUS (Irish Health Repository)

    Cronin, C C

    2012-02-03

    Abnormalities of the renin-angiotensin system have been reported in patients with diabetes mellitus and with diabetic complications. In this study, plasma concentrations of prorenin, renin, and aldosterone were measured in a stratified random sample of 110 insulin-dependent (Type 1) diabetic patients attending our outpatient clinic. Fifty-four age- and sex-matched control subjects were also examined. Plasma prorenin concentration was higher in patients without complications than in control subjects when upright (geometric mean (95% confidence intervals (CI): 75.9 (55.0-105.6) vs 45.1 (31.6-64.3) mU I-1, p < 0.05). There was no difference in plasma prorenin concentration between patients without and with microalbuminuria and between patients without and with background retinopathy. Plasma renin concentration, both when supine and upright, was similar in control subjects, in patients without complications, and in patients with varying degrees of diabetic microangiopathy. Plasma aldosterone was suppressed in patients without complications in comparison to control subjects (74 (58-95) vs 167 (140-199) ng I-1, p < 0.001) and was also suppressed in patients with microvascular disease. Plasma potassium was significantly higher in patients than in control subjects (mean +\\/- standard deviation: 4.10 +\\/- 0.36 vs 3.89 +\\/- 0.26 mmol I-1; p < 0.001) and plasma sodium was significantly lower (138 +\\/- 4 vs 140 +\\/- 2 mmol I-1; p < 0.001). We conclude that plasma prorenin is not a useful early marker for diabetic microvascular disease. Despite apparently normal plasma renin concentrations, plasma aldosterone is suppressed in insulin-dependent diabetic patients.

  15. Clinical significance of determination of plasma ADM concentrations in hyperthyroid patients complicated with pulmonary hypertension

    International Nuclear Information System (INIS)

    Wang Kaiqin; Zhang Jing

    2006-01-01

    Objective: To investigate the plasma adrenomedullin (ADM) concentrations in hyperthyroid patients with or without pulmonary hypertension. Methods: Plasma ADM levels were measured with RIA in: (1) 30 hyperthyroid patients without pulmonary hypertension, (2) 27 hyperthyroid patients with pulmonary, hypertension, and (3) 32 controls. Results: (1) In this study, 27 of the 57 hyperthyroid patients were complicated with pulmonary hypertension (47.37%), (2) Plasma ADM concentrations in the patients with pulmonary hypertension were significantly higher than those in patients without pulmonary hypertension and controls (P 3 , T 4 (thyroid hormones) were positively correlated with those of ADM while there were no correlations in controls. Conclusion: Plasma ADM concentrations increased in hyperthyroid patients, especially in those complicated with pulmonary hypertension. The clinicians should look for pulmonary hypertension in hyperthyroid patients with substantially elevated levels of ADM. (authors)

  16. Reliability of basal plasma vasopressin concentrations in healthy male adults.

    Science.gov (United States)

    Quintana, Daniel S; Westlye, Lars T; Smerud, Knut T; Mahmoud, Ramy A; Djupesland, Per G; Andreassen, Ole A

    2017-10-01

    The neuropeptides oxytocin (OT) and arginine vasopressin (AVP) play important and interrelated roles in modulating mammalian social behaviour. While the OT system has received considerable research attention for its potential to treat psychiatric symptoms, comparatively little is known about the role of the AVP system in human social behaviour. To better understand the intraindividual stability of basal AVP, the present study assessed the reproducibility of basal plasma AVP concentrations. Basal plasma AVP was assessed at four sampling points separated by 8 days, on average, in 16 healthy adult males. Only one out of six comparisons revealed strong evidence for reproducibility of basal AVP concentrations (visit 2 vs. visit 4: r=0.8, p0.1). The concordance correlation coefficient [0.15, 95% CI (-0.55, 0.73)] also revealed poor overall reproducibility. Poor reliability of basal AVP concentrations suggests future work covarying AVP with trait markers should proceed with careful consideration of intraindividual fluctuations.

  17. Interferometric measurements of plasma density in high-β plasmas

    International Nuclear Information System (INIS)

    Quinn, W.E.

    1977-01-01

    The coupled-cavity laser interferometer technique is particularly applicable to the measurement of pulsed plasma densities. This technique is based on the fact that if a small fraction of a gas laser's output radiation is reflected into the laser with an external mirror, the intensity of the laser output is modulated. These amplitude or intensity modulations are produced by changes in the laser gain. A rotating corner mirror or an oscillating mirror can be used to produce a continuous feedback modulation of the interferometer which produces a continuous background fringe pattern. The presence of plasma in the outer cavity causes an additional change which results in a phase shift of the regular period of the background fringe pattern. The integral of the plasma density along the line of sight can be evaluated by comparison of the time history of the fringes obtained with and without plasma

  18. Plasma fluctuation measurements in tokamaks using beam-plasma interactions

    International Nuclear Information System (INIS)

    Fonck, R.J.; Duperrex, P.A.; Paul, S.F.

    1990-01-01

    High-frequency observations of light emitted from the interactions between plasma ions and injected neutral beam atoms allow the measurement of moderate-wavelength fluctuations in plasma and impurity ion densities. To detect turbulence in the local plasma ion density, the collisionally excited fluorescence from a neutral beam is measured either separately at several spatial points or with a multichannel imaging detector. Similarly, the role of impurity ion density fluctuations is measured using charge exchange recombination excited transitions emitted by the ion species of interest. This technique can access the relatively unexplored region of long-wavelength plasma turbulence with k perpendicular ρ i much-lt 1, and hence complements measurements from scattering experiments. Optimization of neutral beam geometry and optical sightlines can result in very good localization and resolution (Δx≤1 cm) in the hot plasma core region. The detectable fluctuation level is determined by photon statistics, atomic excitation processes, and beam stability, but can be as low as 0.2% in a 100 kHz bandwidth over the 0--1 MHz frequency range. The choices of beam species (e.g., H 0 , He 0 , etc.), observed transition (e.g., H α , L α , He I singlet or triplet transitions, C VI Δn=1, etc.) are dictated by experiment-specific factors such as optical access, flexibility of beam operation, plasma conditions, and detailed experimental goals. Initial tests on the PBX-M tokamak using the H α emissions from a heating neutral beam show low-frequency turbulence in the edge plasma region

  19. Continuous measurements of outdoor radon concentrations

    International Nuclear Information System (INIS)

    Iida, T.; Ikebe, Y.; Suzuki, K.; Ueno, K.; Komura, K.; Kato, I.; Jin Yihe

    1993-01-01

    The authors studied and developed an electrostatic 222 Rn monitor and have measured continuously outdoor radon ( 222 Rn) concentrations at Nagoya University since 1985. Four 222 Rn monitors were newly constructed to measure outdoor 222 Rn concentrations at other locations. The 222 Rn concentrations at Nagoya and Kasugai show a clear diurnal variation in autumn, and a seasonal pattern of a spring-summer minimum and a autumn-winter maximum. The results at Toki are the same pattern as that at Nagoya except spring. The concentrations at Kanazawa show a slight seasonal variation. A clear diurnal variation is observed in summer. (4 figs.)

  20. Measuring methods for the TFR plasma diagnostics

    International Nuclear Information System (INIS)

    Etievant, C.

    1975-02-01

    The measuring methods in operation or still under development for the diagnostics of the TFR plasma parameters (ion and electron temperatures, electron density, current density are reviewed, the diagnostics of the electrical behavior of the discharge, the neutral gas densities, the impurities and the parameters of the plasma turbulence being also investigated. Actual works are principally devoted to: improving ion temperature measurements by the possible use of the Doppler effect or infra-red incoherent scattering; improving n(e) and T(e) measurement by Thomson scattering; measuring the poloidal field and current density; measuring impurities by X and UV spectroscopy and measuring instabilities and turbulence [fr

  1. Absence of a relation between efavirenz plasma concentrations and toxicity-driven efavirenz discontinuations in the EuroSIDA study

    DEFF Research Database (Denmark)

    van Luin, Matthijs; Bannister, Wendy P; Mocroft, Amanda

    2009-01-01

    plasma concentrations were measured from patients in the EuroSIDA study starting EFV after 1 January 1999. Patients with a plasma concentration available were divided into those that discontinued EFV because of any toxicity or by the choice of the patient or physician within 2 years (TOXPC group...

  2. Do plasma concentrations of apelin predict prognosis in patients with advanced heart failure?

    Science.gov (United States)

    Dalzell, Jonathan R; Jackson, Colette E; Chong, Kwok S; McDonagh, Theresa A; Gardner, Roy S

    2014-01-01

    Apelin is an endogenous vasodilator and inotrope, plasma concentrations of which are reduced in advanced heart failure (HF). We determined the prognostic significance of plasma concentrations of apelin in advanced HF. Plasma concentrations of apelin were measured in 182 patients with advanced HF secondary to left ventricular systolic dysfunction. The predictive value of apelin for the primary end point of all-cause mortality was assessed over a median follow-up period of 544 (IQR: 196-923) days. In total, 30 patients (17%) reached the primary end point. Of those patients with a plasma apelin concentration above the median, 14 (16%) reached the primary end point compared with 16 (17%) of those with plasma apelin levels below the median (p = NS). NT-proBNP was the most powerful prognostic marker in this population (log rank statistic: 10.37; p = 0.001). Plasma apelin concentrations do not predict medium to long-term prognosis in patients with advanced HF secondary to left ventricular systolic dysfunction.

  3. Plasma N-terminal pro B-type natriuretic peptide concentrations in dogs with pulmonic stenosis.

    Science.gov (United States)

    Kobayashi, Keiya; Hori, Yasutomo; Chimura, Syuuichi

    2014-06-01

    The detailed information between plasma N-terminal pro B-type natriuretic peptide (NT-proBNP) concentrations and dogs with pulmonic stenosis (PS) is still unknown. The aim of the present study was to investigate the clinical utility of measuring plasma NT-proBNP concentrations in dogs with PS and to determine whether plasma NT-proBNP concentration could be used to assess disease severity. This retrospective study enrolled 30 client-owned, untreated dogs with PS (asymptomatic [n=23] and symptomatic [n=7]) and 11 healthy laboratory beagles. Results of physical examination, thoracic radiography and echocardiography were recorded. Plasma NT-proBNP concentrations were measured using commercial laboratories. Compared to the healthy control dogs, cardiothoracic ratio was significantly increased in dogs with both asymptomatic and symptomatic PS. Similarly, the ratio of the main pulmonary artery to aorta was significantly decreased in dogs with both asymptomatic and symptomatic PS. The pulmonic pressure gradient in the symptomatic PS dogs was significantly higher than that in the asymptomatic PS dogs. Plasma NT-proBNP concentration was significantly elevated in the symptomatic PS dogs compared to the healthy control dogs and the asymptomatic PS dogs. Furthermore, the Doppler-derived pulmonic pressure gradient was significantly correlated with the plasma NT-proBNP concentration (r=0.78, r(2)=0.61, P764 pmol/l to identify severe PS had a sensitivity of 76.2% and specificity of 81.8%. The plasma NT-proBNP concentration increased by spontaneous PS, i.e. right-sided pressure overload and can be used as an additional method to assess the severity of PS in dogs.

  4. Curcuminoids Lower Plasma Leptin Concentrations: A Meta-analysis.

    Science.gov (United States)

    Atkin, Stephen L; Katsiki, Niki; Derosa, Giuseppe; Maffioli, Pamela; Sahebkar, Amirhossein

    2017-12-01

    Curcumin is a naturally occurring polyphenol that has been suggested to improve several metabolic diseases. Leptin is an adipokine involved in metabolic status and appetite, with marked crosstalk with other systems. Available data suggest that curcumin may affect leptin levels; therefore, this meta-analysis was performed to evaluate this. A systematic review and meta-analysis were undertaken on all randomized controlled trials of curcumin studies that included the measurement of leptin. The search included PubMed-Medline, Scopus, ISI Web of Knowledge, and Google Scholar databases. Quantitative data synthesis was performed by using a random-effects model, with standardized mean difference and 95% confidence interval as summary statistics. A funnel plot, Begg's rank correlation, and Egger's weighted regression tests assessed the presence of publication bias. Four eligible articles comprising five treatment arms were selected for the meta-analysis. Meta-analysis showed a significant decrease in plasma leptin concentrations following curcumin treatment (standardized mean difference: -0.69, 95% confidence interval: -1.16, -0.23, p = 0.003; I 2  = 76.53%). There was no evidence of publication bias. This meta-analysis showed that curcumin supplementation is associated with a decrease in leptin levels that may be regarded as a potential mechanism for the metabolic effects of curcumin. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  5. The laser, measuring instrument for plasmas

    International Nuclear Information System (INIS)

    Anderegg, F.; Behn, R.; Paris, P.J.; Salito, S.A.; Siegrist, M.R.; Weisen, H.

    1988-06-01

    There are several different and in general complementary methods for the investigation of plasmas. All of them have different characteristics and properties covering a large spectrum of physical measuring techniques. Electromagnetic waves serving as 'thermometers' permit to detect the global behaviour of the plasma as well as that of the particles composing it. One of the advantages of these introspective methods is that it brings information on temporary and local conditions of the domain being interrogated. With the development of micro-wave sources and lasers after the war the principal tools of this type of plasma diagnostics are now available. In this paper the emphasis is on the lasers which are different according to the type of measurement. Their versatility in measuring plasma parameters is largely acknowledged. We illustrate the potential of measuring methods by lasers by means of the research work done at two experimental installations of CRPP. (author) 21 figs., 8 refs

  6. Subjective satiety and plasma PYY concentration after wholemeal pasta.

    Science.gov (United States)

    Costabile, Giuseppina; Griffo, Ettore; Cipriano, Paola; Vetrani, Claudia; Vitale, Marilena; Mamone, Gianfranco; Rivellese, Angela A; Riccardi, Gabriele; Giacco, Rosalba

    2018-06-01

    Dietary fiber and whole grain foods may contribute to the regulation of appetite; however, evidence has produced inconclusive findings. The objective was to evaluate the effects of an experimental wholemeal pasta on appetite ratings, plasma concentrations of gastrointestinal hormones involved in appetite control, and postprandial glucose/insulin responses in healthy adults. Fourteen healthy adults (7M/7F), mean age 30±2 yrs (mean±SEM), participated in a randomized, controlled, crossover trial. Participants consumed on two different days, at one week interval, 117g of wholemeal pasta or 100g of refined wheat pasta (control pasta), similar in energy and macronutrient composition except for fiber amount, which was higher in wholemeal pasta (11 vs 3 g). Appetite ratings, glucose/insulin/lipid and gastrointestinal hormone responses were measured at fasting and for 4-h after the ingestion of the pasta tests, after which self-reported energy intake for 8-h was evaluated. After the wholemeal pasta, the desire to eat and the sensation of hunger were lower (-16%, p=0.04 and -23%, p=0.004, respectively) and satiety was higher (+13%; p=0.08) compared with the control pasta; no effect on self-reported energy intake at subsequent meal was observed. After wholemeal pasta, glucose, triglyceride increased and GLP-1 responses were not different compared to control pasta but insulin response at 30 min (ppasta contributed to appetite control but did not seem to influence acute energy balance. Appetite ratings were associated with modifications in PYY hormone concentrations. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Lapatinib Plasma and Tumor Concentrations and Effects on HER Receptor Phosphorylation in Tumor.

    Directory of Open Access Journals (Sweden)

    Neil L Spector

    Full Text Available The paradigm shift in cancer treatment from cytotoxic drugs to tumor targeted therapies poses new challenges, including optimization of dose and schedule based on a biologically effective dose, rather than the historical maximum tolerated dose. Optimal dosing is currently determined using concentrations of tyrosine kinase inhibitors in plasma as a surrogate for tumor concentrations. To examine this plasma-tumor relationship, we explored the association between lapatinib levels in tumor and plasma in mice and humans, and those effects on phosphorylation of human epidermal growth factor receptors (HER in human tumors.Mice bearing BT474 HER2+ human breast cancer xenografts were dosed once or twice daily (BID with lapatinib. Drug concentrations were measured in blood, tumor, liver, and kidney. In a randomized phase I clinical trial, 28 treatment-naïve female patients with early stage HER2+ breast cancer received lapatinib 1000 or 1500 mg once daily (QD or 500 mg BID before evaluating steady-state lapatinib levels in plasma and tumor.In mice, lapatinib levels were 4-fold higher in tumor than blood with a 4-fold longer half-life. Tumor concentrations exceeded the in vitro IC90 (~ 900 nM or 500 ng/mL for inhibition of HER2 phosphorylation throughout the 12-hour dosing interval. In patients, tumor levels were 6- and 10-fold higher with QD and BID dosing, respectively, compared to plasma trough levels. The relationship between tumor and plasma concentration was complex, indicating multiple determinants. HER receptor phosphorylation varied depending upon lapatinib tumor concentrations, suggestive of changes in the repertoire of HER homo- and heterodimers.Plasma lapatinib concentrations underestimated tumor drug levels, suggesting that optimal dosing should be focused on the site of action to avoid to inappropriate dose escalation. Larger clinical trials are required to determine optimal dose and schedule to achieve tumor concentrations that maximally

  8. Low plasma adiponectin concentrations do not predict weight gain in humans

    DEFF Research Database (Denmark)

    Vozarova, Barbora; Stefan, Norbert; Lindsay, Robert S

    2002-01-01

    Low concentrations of plasma adiponectin, the most abundant adipose-specific protein, are observed in obese individuals and predict the development of type 2 diabetes. Administration of adiponectin to rodents prevented diet-induced weight gain, suggesting a potential etiologic role of hypoadipone......Low concentrations of plasma adiponectin, the most abundant adipose-specific protein, are observed in obese individuals and predict the development of type 2 diabetes. Administration of adiponectin to rodents prevented diet-induced weight gain, suggesting a potential etiologic role...... of hypoadiponectinemia in the development of obesity. Our aim was to prospectively examine whether low plasma adiponectin concentrations predict future weight gain in Pima Indians, explaining the predictive effect of adiponectin on the development of type 2 diabetes. We measured plasma adiponectin concentrations in 219...... nondiabetic Pima Indians (112 M/107 F, age 31 +/- 9 years, body weight 96 +/- 20 kg [mean +/- SD]) in whom body weight and height were measured and BMI calculated at baseline and follow-up. Cross-sectionally, plasma adiponectin concentrations were negatively associated with body weight (r = -0.28, P = 0...

  9. Plasma intermedin concentration in patients with chronic heart faliure

    International Nuclear Information System (INIS)

    Yu Xiaohua; Du Xingbang; Zhu Yunhe; Luo Lei; Zhao Changjun; Liu Yongfeng; Ren Liangping; Ren Yongsheng

    2011-01-01

    Objective: To study the clinical significance of determination of changes of plasma levels of intermedin (IMD), BNP and CRP in patients with chronic heart failure. Methods: Plasma IMD, BNP (with RIA) and CRP (with immuno-turbidity) levels were determined in 46 patients with chronic heart failure of various grades (grade I-II n=31, grade III-IV, n=15) and 42 normal controls. Results: Compared with the control group,the plasma IMD level in patients with chronic heart failure was decreased 53.2% (P<0.01), the BNP and CRP were increased 1658.5% and 80.5% respectively (each P<0.001). Compared with the grade I-II group, the plasma IMD level in grade III-IV was decreased 34.7% (P<0.05), the BNP and CRP levels in grade III-IV were increased 257.8% and 76% (all P<0.001) individually. Conclusion: Plasma intermedin concentration was significantly decreased in patients with chronic heart failure, which suggests that they play an important role in the pathogenesis of chronic heart failure. (authors)

  10. Concentration and limit behaviors of stationary measures

    Science.gov (United States)

    Huang, Wen; Ji, Min; Liu, Zhenxin; Yi, Yingfei

    2018-04-01

    In this paper, we study limit behaviors of stationary measures of the Fokker-Planck equations associated with a system of ordinary differential equations perturbed by a class of multiplicative noise including additive white noise case. As the noises are vanishing, various results on the invariance and concentration of the limit measures are obtained. In particular, we show that if the noise perturbed systems admit a uniform Lyapunov function, then the stationary measures form a relatively sequentially compact set whose weak∗-limits are invariant measures of the unperturbed system concentrated on its global attractor. In the case that the global attractor contains a strong local attractor, we further show that there exists a family of admissible multiplicative noises with respect to which all limit measures are actually concentrated on the local attractor; and on the contrary, in the presence of a strong local repeller in the global attractor, there exists a family of admissible multiplicative noises with respect to which no limit measure can be concentrated on the local repeller. Moreover, we show that if there is a strongly repelling equilibrium in the global attractor, then limit measures with respect to typical families of multiplicative noises are always concentrated away from the equilibrium. As applications of these results, an example of stochastic Hopf bifurcation and an example with non-decomposable ω-limit sets are provided. Our study is closely related to the problem of noise stability of compact invariant sets and invariant measures of the unperturbed system.

  11. Effect of pregnancy on plasma phenobarbital concentrations in rats.

    OpenAIRE

    Moriyama, Masahiro; Domoto, Haruyo; Yamashita, Syoichi; Furuno, Katsushi; Oishi, Ryozo; Kawasaki, Hiromu; Gomita, Yutaka

    1995-01-01

    We examined the pharmacokinetics of phenobarbital before and during pregnancy in rats. Animals were divided into four groups: (a) control, (b) pregnant, (c) phenobarbital-treated, and (d) phenobarbital-treated pregnant groups. The increase in body weight of nonpregnant or pregnant rats was not influenced by long-term phenobarbital treatment. Plasma phenobarbital concentrations during the period of long-term phenobarbital treatment with a fixed dosage by body weight were not significantly affe...

  12. Elevated circulating plasma endothelin-1 concentrations in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Emmeluth, C; Henriksen, Jens Henrik

    1993-01-01

    veins on the one hand and the femoral artery on the other (P > 0.1), indicating no major net elimination or release in the liver, kidney or lower limb. A significant negative correlation was found between systolic and diastolic blood pressures on the one hand and circulating ET-1 on the other (r = -0.......70, P vein catheterization (n = 8), no significant differences were found in ET-1 plasma concentration between the liver, renal, or femoral...

  13. Precise Charge Measurement For Laser Plasma Accelerators

    International Nuclear Information System (INIS)

    Nakamura, Kei; Gonsalves, Anthony; Lin, Chen; Sokollik, Thomas; Shiraishi, Satomi; van Tilborg, Jeroen; Osterhoff, Jens; Donahue, Rich; Rodgers, David; Smith, Alan; Byrne, Warren; Leemans, Wim

    2011-01-01

    Cross-calibrations of charge diagnostics are conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs). Employed diagnostics are a scintillating screen, activation based measurement, and integrating current transformer. The diagnostics agreed within ±8 %, showing that they can provide accurate charge measurements for LPAs provided they are used properly.

  14. Measurements of natural 41Ca concentrations

    International Nuclear Information System (INIS)

    Steinhof, A.

    1989-05-01

    Atomic mass spectroscopic examinations on 41 Ca were carried out in the UNILAC accelerator. A sensitivity of about 10 -15 was achieved. This would allow the measurement of present natural 41 Ca concentrations as soon as the problem of the transmission determination is solved. In this respect suggestions were worked out and their feasibility discussed. The detection of 41 Ca-ions is especially free of background when high UNILAC-energies are applied. An estimation showed a background level corresponding with a 41 Ca concentration of less then 10 -17 referred to 40 Ca. Besides an independent concept for the electromagnetic concentration of 41 Ca with variable concentration factors was developed. After being concentrated up to 50 respectively 25 times the initial concentration in the GSI mass separator, the 41 Ca concentration of three recent deer bones found in the Odenwald was measured by atomic mass spectroscopy in the 14UD-Pelletron Tandem in Rehovot (Israel). The measured 41 Ca concentrations ranged between 10 -14 to 10 -13 with consideration of the concentration factor. A theoretical study of the 41 Ca production in the earth's surface based on cosmic radiation illustrates the influence of trace elements on the neutron flux and thus on the 41 Ca production. This influence might be a possible explanation for the observed amplitude of variation of the 41 Ca concentration in recent bones which are of decisive importance for the feasibility of 41 Ca-related dating. In this work a method is suggested that does not depend on the amplitude of variation mentioned above and which would allow the determination of the erosion rate of rocks by its 41 Ca concentrations. (orig./HP) [de

  15. 2. Basis of measurement of plasma flow. 2.3 Plasma flow measurements. Spectroscopic methods

    International Nuclear Information System (INIS)

    Kado, Shinichiro

    2007-01-01

    The construction of optical system, optical fiber incident system, reciprocal linear dispersion, grating smile and astigmatism of the reflection plane diffraction grating spectrometer are explained in order to measure the plasma flow. The specification of flow measurement and evaluation of 0 point of velocity are stated. For examples of measurements, the fine structures of He II (Δn = 3 - 4) in material and plasma(MAP)-II of Tokyo University, plasma flow measurement by the charge exchange recombination spectroscopy using Large Helical Device and by Zeeman spectroscopy using TRIAM-1M tokamak plasma are stated. (S.Y.)

  16. Fasting plasma chenodeoxycholic acid and cholic acid concentrations are inversely correlated with insulin sensitivity in adults

    Directory of Open Access Journals (Sweden)

    Laville Martine

    2011-07-01

    Full Text Available Abstract Background Accumulating data suggest a novel role for bile acids (BAs in modulating metabolic homeostasis. BA treatment has been shown to improve glucose tolerance and to increase energy expenditure in mice. Here, we investigated the relationship between fasting plasma BAs concentrations and metabolic parameters in humans. Findings Fasting plasma glucose, insulin and lipid profile were measured in 14 healthy volunteers, 20 patients with type 2 diabetes (T2D, and 22 non-diabetic abdominally obese subjects. Insulin sensitivity was also assessed by the determination of the glucose infusion rate (GIR during a hyperinsulinemic-euglycemic clamp in a subgroup of patients (9 healthy and 16 T2D subjects. Energy expenditure was measured by indirect calorimetry. Plasma cholic acid (CA, chenodeoxycholic acid (CDCA and deoxycholic acid (DCA concentrations were analyzed by gas chromatograph-mass spectrometry. In univariable analysis, a positive association was found between HOMA-IR and plasma CDCA (β = 0.09, p = 0.001, CA (β = 0.03, p = 0.09 and DCA concentrations (β = 0.07, p Conclusions Both plasma CDCA, CA and DCA concentrations were negatively associated with insulin sensitivity in a wide range of subjects.

  17. Effect of physiological determinants and cardiac disease on plasma adiponectin concentrations in dogs.

    Science.gov (United States)

    Damoiseaux, C; Merveille, A-C; Krafft, E; Da Costa, A M; Gomart, S; Jespers, P; Michaux, C; Clercx, C; Verhoeven, C; Mc Entee, K

    2014-01-01

    In humans, a high concentration of adiponectin is associated with a favorable cardiovascular risk profile whereas, in patients with heart failure (HF), a high concentration of adiponectin is associated with a less favorable prognosis. To evaluate the physiological determinants of plasma adiponectin concentration in dogs and the influence of heart disease, myxomatous mitral valve disease (MMVD), and dilated cardiomyopathy (DCM). One hundred and fourteen client-owned dogs and 9 Beagles from the research colony of the Clinical Veterinary Unit of the University of Liège. We prospectively measured circulating adiponectin concentration in healthy control dogs (n = 77), dogs with MMVD (n = 22) and dogs with DCM (n = 15) of various degrees of severity. Diagnosis was confirmed by Doppler echocardiography. Plasma adiponectin concentration was measured by a canine-specific sandwich ELISA kit. An analysis of covariance showed an association between adiponectin concentration and age, neuter status, and heart disease. No association between adiponectin concentration and class of HF, sex, body condition score, body weight, circadian rhythm, or feeding was found. Plasma adiponectin concentration was negatively correlated with age (P = .001). Adiponectin was lower in neutered (P = .008) compared to intact dogs. Circulating adiponectin concentration was increased in dogs with DCM compared to healthy dogs (P = .018) and to dogs with MMVD (P = .014). Age and neutering negatively influence circulating adiponectin concentration. Plasma adiponectin concentration increased in dogs with DCM. Additional research is required to investigate if this hormone is implicated in the pathophysiology of DCM and associated with clinical outcome. Copyright © 2014 by the American College of Veterinary Internal Medicine.

  18. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.

    Science.gov (United States)

    Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.

  19. Plasma concentrations of fentanyl with subcutaneous infusion in palliative care patients.

    OpenAIRE

    Miller, R S; Peterson, G M; Abbott, F; Maddocks, I; Parker, D; McLean, S

    1995-01-01

    1. Plasma concentrations of fentanyl were measured by g.c. in 20 patients (median age: 75 years and range: 54-86 years; eight females) in palliative care receiving the drug by continuous s.c. infusion (median rate: 1200 micrograms day-1 and range: 100-5000 micrograms day-1). 2. The infusion rate was significantly related to the duration of therapy (Spearman rho = 0.56, P < 0.05). The total steady-state plasma concentrations of fentanyl ranged between 0.1 and 9 ng ml-1, with a median of 1 ng m...

  20. Plasma concentrations of fentanyl with subcutaneous infusion in palliative care patients.

    Science.gov (United States)

    Miller, R S; Peterson, G M; Abbott, F; Maddocks, I; Parker, D; McLean, S

    1995-12-01

    1. Plasma concentrations of fentanyl were measured by g.c. in 20 patients (median age: 75 years and range: 54-86 years; eight females) in palliative care receiving the drug by continuous s.c. infusion (median rate: 1200 micrograms day-1 and range: 100-5000 micrograms day-1). 2. The infusion rate was significantly related to the duration of therapy (Spearman rho = 0.56, P Infusion rates and both total and unbound plasma concentrations of fentanyl were correlated (Spearman rho = 0.92, P infusion in the palliative care setting, which necessitates careful titration of dosage according to individual clinical response.

  1. Plasma D-dimer concentration in patients with systemic sclerosis

    Directory of Open Access Journals (Sweden)

    Montagnana Martina

    2006-01-01

    Full Text Available Abstract Background Systemic sclerosis (SSc is an autoimmune disorder of the connective tissue characterized by widespread vascular lesions and fibrosis. Little is known so far on the activation of the hemostatic and fibrinolytic systems in SSc, and most preliminary evidences are discordant. Methods To verify whether SSc patients might display a prothrombotic condition, plasma D-dimer was assessed in 28 consecutive SSc patients and in 33 control subjects, matched for age, sex and environmental habit. Results and discussion When compared to healthy controls, geometric mean and 95% confidence interval (IC95% of plasma D-dimer were significantly increased in SSc patients (362 ng/mL, IC 95%: 361–363 ng/mL vs 229 ng/mL, IC95%: 228–231 ng/mL, p = 0.005. After stratifying SSc patients according to disease subset, no significant differences were observed between those with limited cutaneous pattern and controls, whereas patients with diffuse cutaneous pattern displayed substantially increased values. No correlation was found between plasma D-dimer concentration and age, sex, autoantibody pattern, serum creatinine, erythrosedimentation rate, nailfold videocapillaroscopic pattern and pulmonary involvement. Conclusion We demonstrated that SSc patients with diffuse subset are characterized by increased plasma D-dimer values, reflecting a potential activation of both the hemostatic and fibrinolytic cascades, which might finally predispose these patients to thrombotic complications.

  2. Plasma methylphenidate concentrations in youths treated with high-dose osmotic release oral system formulation.

    Science.gov (United States)

    Stevens, Jonathan R; George, Robert A; Fusillo, Steven; Stern, Theodore A; Wilens, Timothy E

    2010-02-01

    Children and adolescents are being treated increasingly for attention-deficit/hyperactivity disorder (ADHD) with a variety of stimulants in higher than Food and Drug Administration (FDA)-approved doses and in combination with other medications. We sought to determine methylphenidate (MPH) concentrations in children and adolescents treated with high-dose, extended-release osmotic release oral system (OROS) MPH plus concomitant medications, and to examine MPH concentrations with respect to the safety and tolerability of treatment. Plasma MPH concentrations were measured by liquid chromatography-mass spectrometry 4-5 hours after administration of medication in a sample of youths diagnosed with ADHD. These youths were treated naturalistically with higher than FDA-approved doses of OROS MPH in addition to their concomitant medications. Markers of safety and tolerability (e.g., measures of blood pressure and heart rate) were also examined. Among the 17 patients (with a mean age of 16.2 +/- 2 years and a mean number of concurrent medications of 2.23 +/- 0.94), the mean plasma MPH concentration was 28 +/- 9.1 ng/mL, despite a mean daily dose of OROS MPH of 169 +/- 5 mg (3.0 +/- 0.8 mg/kg per day). No patient had a plasma MPH level >or=50 ng/mL or clinical signs of stimulant toxicity. No correlation was found between plasma MPH concentrations and OROS MPH dose or changes in vital signs. High-dose OROS MPH, used in combination with other medications, was not associated with either unusually elevated plasma MPH concentrations or with clinically meaningful changes in vital signs. Study limitations include a single time-point sampling of MPH concentrations, a small sample size, and a lack of outcome measures to address treatment effectiveness.

  3. Endostatin concentration in plasma of healthy human volunteers

    International Nuclear Information System (INIS)

    Shah, I.; Malik, M.O.; Khan, M.J.; Fatima, S.; Habib, S.H.

    2017-01-01

    Angiogenesis is involved in many cardiovascular and cancerous diseases, including atherosclerosis and is controlled by a fine balance between angiogenic and angiostatic mediators. Endostatin is one of the main angiostatic mediators, and inhibits angiogenesis and prevents progression of atherosclerosis. The available literature shows a broad range of concentrations in relatively small samples of healthy controls and is calculated by using different techniques. This study was aimed to determine the basal endostatin concentration in plasma of healthy volunteers, to fully understand its physiological role. Methods: Fifty healthy adult volunteers were recruited to the study. Participants were advised not to participate in any physical activity on the day before the blood sampling. The volunteers' physical activity, height, weight, heart rate and blood pressure were recorded. The samples were analysed for plasma endostatin concentration, using ELISA. The participants were divided by gender and ethnic groups to calculate any difference. Results: Endostatin and other variables were normally distributed. Most of the participants had a moderate level of physical activity with no gender related difference (p=0.370). The mean value for plasma endostatin in all samples was 105+-12 ng/ml with range of 81-132 ng/ml. For males, it was 107+-13 ng/ml, while for females; 102+-12 ng/ml. There were no significant gender or ethnicity related differences in endostatin concentration. Moreover, endostatin was not significantly related with any anthropometric and physical variable. Conclusion: This study gives endostatin levels in normal healthy people and show no gender and ethnicity related differences in endostatin levels. Endostatin was not related with any anthropometric and physical variable. (author)

  4. Plasma oxytocin concentrations are lower in depressed vs. healthy control women and are independent of cortisol.

    Science.gov (United States)

    Yuen, Kaeli W; Garner, Joseph P; Carson, Dean S; Keller, Jennifer; Lembke, Anna; Hyde, Shellie A; Kenna, Heather A; Tennakoon, Lakshika; Schatzberg, Alan F; Parker, Karen J

    2014-04-01

    The neuropeptide oxytocin (OT) promotes social behavior and attenuates stress responsivity in mammals. Recent clinical evidence suggests OT concentrations may be dysregulated in major depression. This study extends previous research by testing whether: 1) OT concentrations vary systematically in depressive disorders with and without hypercortisolemia, 2) gender differences in OT concentrations are observed in depressed vs. healthy control participants, and 3) OT concentrations are predictive of clinical phenotypes. Plasma OT concentrations of psychotic major depressive (PMD; n = 14: 10 female, 4 male), non-psychotic major depressive (NPMD; n = 17: 12 female, 5 male), and non-depressed, healthy control (n = 19: 11 female, 8 male) participants were assayed at 2000, 2400, 0400, and 0800 h. Plasma cortisol concentrations were quantified at 2300 h, and clinical phenotypes were determined. As expected, PMD participants, compared to NPMD and healthy control participants, showed higher plasma cortisol concentrations. Although both depressed groups showed similar OT concentrations, a significant interaction effect between group and gender was observed. Specifically, depressed females exhibited lower mean OT concentrations than depressed males. Further, depressed vs. healthy control female participants exhibited lower mean OT concentrations, whereas depressed vs. healthy control male participants showed a trend in the opposite direction. OT concentrations were also predictive of desirability, drug dependence, and compulsivity scores as measured by the Million Clinical Multiaxial Inventory-III. All findings were independent of cortisol. These data suggest that OT signaling may provide a mechanism by which to better understand female-biased risk to develop depressive disorders and that plasma OT concentrations may be a useful biomarker of certain clinical phenotypes. Copyright © 2013. Published by Elsevier Ltd.

  5. Measurement of tritium concentration in urine

    International Nuclear Information System (INIS)

    Sekiyama, Shigenobu; Deshimaru, Takehide

    1979-01-01

    Concerning the safety management of the advanced thermal reactor ''Fugen'', the internal exposure management for tritium is important, because heavy water is used as the moderator in the reactor, and tritium is produced in the heavy water. Tritium is the radioactive nuclide with the maximum β-ray energy of 18 keV, and the radiation exposure is limited to the internal exposure in human bodies, as tritium is taken in through the skin and by breathing. The tritium concentration in urine of the operators of the Fugen plant was measured. As for tritium measurement, the analysis of raw urine, the analysis after passing through mixed ion exchange resin and the analysis after distillation are applied. The scintillator, the liquid scintillation counter, the ion exchange resin and the distillator are introduced. The preliminary survey was conducted on the urine sample, the scintillator the calibration, etc. The measuring condition, the measurement of efficiency, and the limitation of detection with various background are explained, with the many experimental data and the calculating formula. Concerning the measured tritium concentration in urine, the tritium concentrations in distilled urine, raw urine and the urine refined with ion exchange resin were compared, and the correlation formulae are presented. The actual tritium concentration value in urine was less than 50 pci/ml. The measuring methods of raw urine and the urine refined with ion exchange resin are adequate as they are quick and accurate. (Nakai, Y.)

  6. Impact of Annexin A 7 Deficiency on FGF23 Plasma Concentrations

    Directory of Open Access Journals (Sweden)

    Anja T. Umbach

    2016-11-01

    Full Text Available Background/Aims: The release of fibroblast growth factor FGF23, a powerful regulator of 1,25(OH2D3 formation and mineral metabolism, is stimulated by store-operated Ca2+ entry (SOCE, which is accomplished by the pore forming Ca2+ release activated channel protein Orai1. Regulators of Orai1 and thus FGF23 release include serum & glucocorticoid inducible kinase SGK1, a kinase up-regulated by glucocorticosteroids. Some effects of glucocorticoids require the presence of annexin A7, such as suppression of prostaglandin E2 in gastric glands. The present study thus explored whether annexin A7 impacts on FGF23 plasma levels. Methods: Comparisons were made between gene targeted mice lacking functional annexin A7 (Anx7-/- and their wild type littermates (Anx7+/+. Serum C-terminal-FGF23, intact FGF23, 1,25(OH2D3 and PTH concentrations were measured by ELISA or EIA. The serum and urinary phosphate concentrations were measured by colorimetry, the serum Ca2+ concentration and the urinary Ca2+ concentration by flame photometry. Results: Serum C-terminal FGF23 levels and corticosterone levels were significantly higher and serum 1,25(OH2 D3 and PTH levels were significantly lower in Anx7-/- than in Anx7+/+ mice. Water intake was slightly but significantly higher in Anx7-/- mice than in Anx7+/+ mice. No significant difference was observed between Anx7-/- and Anx7+/+ mice in urinary fluid excretion, plasma Ca2+ concentration, plasma phosphate concentration and urinary Ca2+ output. The urinary phosphate output was significantly lower in Anx7-/- mice than in Anx7+/+ mice. Conclusion: Annexin A7 deficiency upregulates FGF23 plasma levels, an effect paralleled by increased corticosterone plasma levels, as well as decreased 1,25(OH2 D3 and PTH plasma levels.

  7. Identification of a Hemolysis Threshold That Increases Plasma and Serum Zinc Concentration.

    Science.gov (United States)

    Killilea, David W; Rohner, Fabian; Ghosh, Shibani; Otoo, Gloria E; Smith, Lauren; Siekmann, Jonathan H; King, Janet C

    2017-06-01

    Background: Plasma or serum zinc concentration (PZC or SZC) is the primary measure of zinc status, but accurate sampling requires controlling for hemolysis to prevent leakage of zinc from erythrocytes. It is not established how much hemolysis can occur without changing PZC/SZC concentrations. Objective: This study determines a guideline for the level of hemolysis that can significantly elevate PZC/SZC. Methods: The effect of hemolysis on PZC/SZC was estimated by using standard hematologic variables and mineral content. The calculated hemolysis threshold was then compared with results from an in vitro study and a population survey. Hemolysis was assessed by hemoglobin and iron concentrations, direct spectrophotometry, and visual assessment of the plasma or serum. Zinc and iron concentrations were determined by inductively coupled plasma spectrometry. Results: A 5% increase in PZC/SZC was calculated to result from the lysis of 1.15% of the erythrocytes in whole blood, corresponding to ∼1 g hemoglobin/L added into the plasma or serum. Similarly, the addition of simulated hemolysate to control plasma in vitro caused a 5% increase in PZC when hemoglobin concentrations reached 1.18 ± 0.10 g/L. In addition, serum samples from a population nutritional survey were scored for hemolysis and analyzed for changes in SZC; samples with hemolysis in the range of 1-2.5 g hemoglobin/L showed an estimated increase in SZC of 6% compared with nonhemolyzed samples. Each approach indicated that a 5% increase in PZC/SZC occurs at ∼1 g hemoglobin/L in plasma or serum. This concentration of hemoglobin can be readily identified directly by chemical hemoglobin assays or indirectly by direct spectrophotometry or matching to a color scale. Conclusions: A threshold of 1 g hemoglobin/L is recommended for PZC/SZC measurements to avoid increases in zinc caused by hemolysis. The use of this threshold may improve zinc assessment for monitoring zinc status and nutritional interventions.

  8. Moringa Oleifera leaf extract increases plasma antioxidant status associated with reduced plasma malondialdehyde concentration without hypoglycemia in fasting healthy volunteers.

    Science.gov (United States)

    Ngamukote, Sathaporn; Khannongpho, Teerawat; Siriwatanapaiboon, Marent; Sirikwanpong, Sukrit; Dahlan, Winai; Adisakwattana, Sirichai

    2016-12-29

    To investigate the effect of Moringa Oleifera leaf extract (MOLE) on plasma glucose concentration and antioxidant status in healthy volunteers. A randomized crossover design was used in this study. Healthy volunteers were randomly assigned to receive either 200 mL of warm water (10 cases) or 200 mL of MOLE (500 mg dried extract, 10 cases). Blood samples were drawn at 0, 30, 60, 90, and 120 min for measuring fasting plasma glucose (FPG), ferric reducing ability of plasma (FRAP), Trolox equivalent antioxidant capacity (TEAC) and malondialdehyde (MDA). FPG concentration was not signifificantly different between warm water and MOLE. The consumption of MOLE acutely improved both FRAP and TEAC, with increases after 30 min of 30 μmol/L FeSO 4 equivalents and 0.18 μmol/L Trolox equivalents, respectively. The change in MDA level from baseline was signifificantly lowered after the ingestion of MOLE at 30, 60, and 90 min. In addition, FRAP level was negatively correlated with plasma MDA level after an intake of MOLE. MOLE increased plasma antioxidant capacity without hypoglycemia in human. The consumption of MOLE may reduce the risk factors associated with chronic degenerative diseases.

  9. Plasma aldosterone concentrations and plasma renin activity in healthy dogs and dogs with hyperadrenocorticism

    NARCIS (Netherlands)

    Javadi, S; Mol, JA; Boer, P; Boer, WH; Runberk, A

    2003-01-01

    The mean (se) basal plasma aldosterone concentrations were significantly lower in 31 dogs with pituitary-dependent hyperadrenocorticism (PDH) (75 [9] pmol/litre) than in 12 healthy dogs (118 [14] pmol/litre), whereas in five dogs with hyperadrenocorticism due to an adrenocortical tumour they were

  10. Plasma bupivacaine concentrations following orbital injections in cats.

    Science.gov (United States)

    Shilo-Benjamini, Yael; Pypendop, Bruno H; Newbold, Georgina; Pascoe, Peter J

    2017-01-01

    To determine plasma bupivacaine concentrations after retrobulbar or peribulbar injection of bupivacaine in cats. Randomized, crossover, experimental trial with a 2 week washout period. Six adult healthy cats, aged 1-2 years, weighing 4.6 ± 0.7 kg. Cats were sedated by intramuscular injection of dexmedetomidine (36-56 μg kg -1 ) and were administered a retrobulbar injection of bupivacaine (0.75 mL, 0.5%; 3.75 mg) and iopamidol (0.25 mL), or a peribulbar injection of bupivacaine (1.5 mL, 0.5%; 7.5 mg), iopamidol (0.5 mL) and 0.9% saline (1 mL) via a dorsomedial approach. Blood (2 mL) was collected before and at 5, 10, 15, 22, 30, 45, 60, 120, 240 and 480 minutes after bupivacaine injection. Atipamezole was administered approximately 30 minutes after bupivacaine injection. Plasma bupivacaine and 3-hydroxybupivacaine concentrations were determined using liquid chromatography-mass spectrometry. Bupivacaine maximum plasma concentration (C max ) and time to C max (T max ) were determined from the data. The bupivacaine median (range) C max and T max were 1.4 (0.9-2.5) μg mL -1 and 17 (4-60) minutes, and 1.7 (1.0-2.4) μg mL -1 , and 28 (8-49) minutes, for retrobulbar and peribulbar injections, respectively. In both treatments the 3-hydroxybupivacaine peak concentration was 0.05-0.21 μg mL -1 . In healthy cats, at doses up to 2 mg kg -1 , bupivacaine peak plasma concentrations were approximately half that reported to cause arrhythmias or convulsive electroencephalogram (EEG) activity in cats, and about one-sixth of that required to produce hypotension. Copyright © 2016 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  11. Brain-derived neurotrophic factor (BDNF) plasma concentration in patients diagnosed with premature ovarian insufficiency (POI).

    Science.gov (United States)

    Czyzyk, Adam; Filipowicz, Dorota; Podfigurna, Agnieszka; Ptas, Paula; Piestrzynska, Malgorzata; Smolarczyk, Roman; Genazzani, Andrea R; Meczekalski, Blazej

    2017-05-01

    Premature ovarian insufficiency (POI) is defined as a cessation of function of ovaries in women younger than 40 years old. Brain-derived neurotrophic factor (BDNF) is a protein critically involved in neuronal growth and metabolism. BDNF also has been shown to be important regulator of oocyte maturation. Recent data show that BDNF can be potentially involved in POI pathology. The aim of the study was to assess the BDNF plasma concentrations in patients diagnosed with idiopathic POI. 23 women diagnosed with POI (age 31 ± 7 years) and 18 (age 31 ± 3) controls were included to the study, matched according to age and body mass index. The BDNF concentrations were measured using competitive enzyme-linked immunosorbent assay (ELISA). Hormonal and metabolic parameters were measured in all individuals, in controls in late follicular phase. The POI group demonstrated lower mean plasma concentrations of BDNF (429.25 ± 65.52 pg/ml) in comparison to healthy controls (479.75 ± 34.75 pg/ml, p = 0.0345). The BDNF plasma concentration correlated negatively (R = -0.79, p BDNF and progesterone in controls. In conclusion, POI patients show significantly lower BDNF plasma concentration and it correlates with the duration of amenorrhea. This observation brings important potential insights to the pathology of POI.

  12. Effect of Postural Change on Plasma Insulin Concentration in Normal Volunteer

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Ho Kyung; Koh, Joo Whan; Joo, Jong Koo; Kim, Jin Yong; Lee, Jang Kyu [Korea Atomic Research Institute, Seoul (Korea, Republic of)

    1974-03-15

    The concentrations of some blood constituents are known to be influenced by the postural change. The blood glucose and insulin concentrations were measured, first, in the supine, and then (30 minutes later) in the erect positions under the fasting state. The effects of a duretic, furose-mide, were also studied under the same condition for 5 consecutive days. The materials were 5 healthy volunteers aging 20-29 years old with out any diabetic past, or family histories. The blood glucose was measured by the Nelson's method, and plasma insulin by the radioimmunoassay method. Following are the results; 1) The plasma insulin concentration in the erect position is slightly higher than in the supine position, however, the increase is statistically insignificant because of the notable individual variations in the values of the supine position. 2) Four out of 5 cases show the increase of about 80% of plasma insulin in the erect position, which is statistically significant if analyzed on the basis of frequency distribution. 3) The blood glucose concentration showed no postural changes. 4) The increase of the plasma insulin concentration in the erect position seems to the result of limited extra vasation of insulin in the lower extremities.

  13. Application of NMR-based metabonomics suggests a relationship between betaine absorption and elevated creatine plasma concentrations in catheterised sows

    DEFF Research Database (Denmark)

    Yde, Christian Clement; Westerhuis, Johan A.; Bertram, Hanne Christine S.

    2012-01-01

    of these metabolites from the small intestine. The LF diet resulted in a higher betaine concentration in the blood than the two high-fibre diets (P¼0·008). This leads to higher plasma concentrations of methionine (P¼0·0028) and creatine (P¼0·020) of endogenous origin. In conclusion, the use of NMR spectroscopy...... for measuring nutrient uptake in the present study elucidated the relationship between betaine uptake and elevated creatine plasma concentrations....

  14. Correlation of plasma and peritoneal diasylate clomipramine concentration with hemodynamic recovery after intralipid infusion in rabbits.

    Science.gov (United States)

    Harvey, Martyn; Cave, Grant; Hoggett, Kerry

    2009-02-01

    Drug sequestration to an expanded plasma lipid phase has been proposed as a potential mechanism of action for lipid emulsions in lipophilic cardiotoxin overdose. The authors set out to document plasma and peritoneal diasylate clomipramine concentration after resuscitation with lipid emulsion in a rabbit model of clomipramine-induced hypotension. Twenty sedated mechanically ventilated New Zealand White rabbits were allocated to receive either 12 mL/kg 20% Intralipid or 12 mL/kg saline solution, following clomipramine infusion to 50% baseline mean arterial pressure (MAP). Hemodynamic parameters and serum clomipramine concentration were determined to 59 minutes. Peritoneal dialysis with 20% Intralipid or saline solution was evaluated for clomipramine concentration. Mean arterial pressure was greater in lipid-treated animals as assessed by repeated-measures analysis of variance (F[1,14] = 6.84; p = 0.020). Lipid infusion was associated with elevated plasma clomipramine concentration and reduced initial volume of distribution (Vd; 5.7 [+/-1.6] L/kg lipid vs. 15.9 [+/-7.2] L/kg saline; p = 0.0001). Peritoneal diasylate clomipramine concentration was greater in lipid-treated animals (366.2 [+/-186.2] microg/L lipid vs. 37.7 [+/-13.8] microg/L saline; p = 0.002). Amelioration of clomipramine-induced hypotension with lipid infusion is associated with reduced initial Vd and elevated plasma clomipramine concentration consistent with intravascular drug-lipid sequestration. Concomitant peritoneal dialysis with lipid emulsion enhances clomipramine extraction.

  15. The plasma and peritoneal fluid concentrations of matrix metalloproteinase-9 are elevated in patients with endometriosis.

    Science.gov (United States)

    Liu, Haiping; Wang, Jianye; Wang, Haiyu; Tang, Ning; Li, Yunfei; Zhang, Yan; Hao, Tianyu

    2016-09-01

    Enzyme matrix metalloproteinase-9 is a member of the matrix metalloproteinase family, which is critical to normal tissue remodelling during embryogenesis and wound healing. In patients with endometriosis, increased expression and activity of matrix metalloproteinase-9 have been observed in ectopic endometrium, but the plasma and peritoneal fluid concentrations of matrix metalloproteinase-9 in patients with endometriosis and their relation to disease severity have not been clear. The aim of the study was to investigate the concentrations of matrix metalloproteinase-9 in plasma and peritoneal fluid of patients with endometriosis. A prospective case-control study was conducted in Jinan Military General Hospital between January 2010 and December 2013. Fifty patients with proven endometriosis and 26 endometriosis-free controls were enrolled in this study. Patients with endometriosis were evaluated and divided into moderate/severe endometriosis group (stage I-II, n = 26) and minimal/mild endometriosis group (stage III-IV, n = 24) according to the revised criteria of the American Society for Reproductive Medicine. Blood samples and peritoneal fluid were obtained from both patients and controls. Matrix metalloproteinase-9 was measured using enzyme-linked immunosorbent assay in plasma and peritoneal fluid. The concentration of matrix metalloproteinase-9 between different groups was compared and its correlation to disease severity was analysed. Plasma and peritoneal fluid concentrations of matrix metalloproteinase-9 in patients with endometriosis were higher than that in controls. In addition, those patients with moderate/severe endometriosis had significantly higher plasma and peritoneal fluid concentrations of matrix metalloproteinase-9 compared to those with minimal/mild endometriosis. Matrix metalloproteinase-9 concentrations in plasma and peritoneal fluid were both positively correlated with severity of endometriosis and plasma matrix metalloproteinase-9

  16. Plasma flow measurements in a simulated low earth orbit plasma

    International Nuclear Information System (INIS)

    Gabriel, S.B.; Mccoy, J.E.; Carruth, M.R. Jr.

    1982-01-01

    The employment of large, higher power solar arrays for space operation has been considered, taking into account a utilization of high operating voltages. In connection with the consideration of such arrays, attention must be given to the fact that the ambient environment of space contains a tenuous low energy plasma which can interact with the high voltage array causing power 'leakage' and arcing. An investigation has been conducted with the aim to simulate the behavior of such an array in low-earth-orbit (LEO). During the experiments, local concentrations of the 'leakage' current were observed when the panel was at a high voltage. These concentrations could overload or damage a small area of cells in a large string. It was hypothesized that this effect was produced by electrostatic focusing of the particles by the sheath fields. To verify this experimentally, an end-effect Langmuir probe was employed. The obtained results are discussed

  17. The association of plasma gamma-aminobutyric acid concentration with postoperative delirium in critically ill patients.

    Science.gov (United States)

    Yoshitaka, Shiho; Egi, Moritoki; Kanazawa, Tomoyuki; Toda, Yuichiro; Morita, Kiyoshi

    2014-12-01

    Delirium is a common complication in postoperative, critically ill patients. The mechanism of postoperative delirium is not well understood but many studies have shown significant associations between benzodiazepine use, alcohol withdrawal and cirrhosis, and an increased risk of delirium. We aimed to investigate a possible link with alterations of gamma-aminobutyric acid (GABA) activity. A prospective observational investigation of 40 patients > 20 years old who had undergone elective surgery with general anaesthesia and were expected to need postoperative intensive care for more than 48 hours. We assessed postoperative delirium using the confusion assessment method in the intensive care unit at 1 hour after the operation and on postoperative Day (POD) 1 and POD 2. We collected blood samples for measurement of plasma GABA concentrations before the operation and on POD 1 and 2. Postoperative delirium and perioperative plasma GABA concentrations in patients with and without delirium. Postoperative delirium occurred in 13 of the patients. Patients with delirium had significantly higher Acute Physiology and Chronic Health Evaluation II scores than patients without delirium. The mean plasma GABA concentration on POD 2 was significantly lower in patients with delirium than in those without delirium. After adjustment of relevant variables, plasma GABA concentration on POD 2 was independently associated with postoperative delirium. Plasma GABA level on POD 2 has a significant independent association with postoperative delirium.

  18. Measurement of concentration of heavy water

    International Nuclear Information System (INIS)

    Tsukamoto, Yuichi; Kondo, Mitsuo; Sakurai, Naoyuki

    1979-01-01

    The concentration of heavy water is measured as one of the technical management in the Fugen plant. The heavy water is used as the moderator in the reactor. The measuring method depends on the theory of light absorption. The light absorption range of heavy water spreads from near infrared to infrared zone. The near infrared absorption was adopted for the purpose, as the absorption is much larger in infrared zone, and the measurement has to be conducted, limiting the apparent absorption. This measuring method is available to determine the concentration of heavy water in the broad range exactly. The preparation of heavy water sample and the measurement of the absorption spectra of near infrared ray are explained, as the experimental procedure. The sample cell was made of quartz, and the spectroscope was the Hitachi 323 type. The resolving power is 100 nm and 27 nm for the wave length of 1000 nm and 2500 nm, respectively. Concerning the measured results, the absorption was recorded in the wave length range from 600 nm to 2600 nm, and for the heavy water concentration range from 0 to 99.77 wt. %. The peaks of absorption were located at the wave length of 1450, 1660, 1920, 1970, 2020 and 2600 nm. The three kinds of fundamental vibration mode of the molecules of both light and heavy water are shown, and the peaks belong to H 2 O, HDO and D 2 O, respectively. The relation between the absorption and the heavy water concentration, and that between the transmissivity and the wave length are shown, when the cell thickness was varied to 5 mm and 20 mm, and the heavy water concentration to 21%, 62% and 99.85%. (Nakai, Y.)

  19. Plasma adiponectin concentrations are associated with dietary glycemic index in Malaysian patients with type 2 diabetes.

    Science.gov (United States)

    Loh, Beng-In; Sathyasuryan, Daniel Robert; Mohamed, Hamid Jan Jan

    2013-01-01

    Adiponectin, an adipocyte-derived hormone has been implicated in the control of blood glucose and chronic inflammation in type 2 diabetes. However, limited studies have evaluated dietary factors on plasma adiponectin levels, especially among type 2 diabetic patients in Malaysia. The aim of this study was to investigate the influence of dietary glycemic index on plasma adiponectin concentrations in patients with type 2 diabetes. A cross-sectional study was conducted in 305 type 2 diabetic patients aged 19-75 years from the Penang General Hospital, Malaysia. Socio-demographic information was collected using a standard questionnaire while dietary details were determined by using a pre-validated semi-quantitative food frequency questionnaire. Anthropometry measurement included weight, height, BMI and waist circumference. Plasma adiponectin concentrations were measured using a commercial ELISA kit. Data were analyzed using multiple linear regression. After multivariate adjustment, dietary glycemic index was inversely associated with plasma adiponectin concentrations (β =-0.272, 95% CI -0.262, - 0.094; pfoods containing high dietary glycemic index that plasma adiponectin level reduced by 0.3 μg/mL. Thirty two percent (31.9%) of the variation in adiponectin concentrations was explained by age, sex, race, smoking status, BMI, waist circumference, HDL-C, triglycerides, magnesium, fiber and dietary glycemic index according to the multiple linear regression model (R2=0.319). These results support the hypothesis that dietary glycemic index influences plasma adiponectin concentrations in patients with type 2 diabetes. Controlled clinical trials are required to confirm our findings and to elucidate the underlying mechanism.

  20. EFFECTS OF CIGARETTE SMOKING ON ERYTHROCYTE ANTIOXIDATIVE ENZYME ACTIVITIES AND PLASMA CONCENTRATIONS OF THEIR COFACTORS

    Directory of Open Access Journals (Sweden)

    M. Zahraie

    2005-07-01

    Full Text Available Tobacco smoke contains numerous compounds, many ‎of which are oxidants and capable of producing free radical and enhancing ‎the oxidative stress. The aim of this study was to investigate the effect of cigarette smoking on the erythrocyte antioxidative enzyme activities and the plasmaconcentration of their cofactors. ‎Sixty eight healthy men were enrolled, 32 of whom had never smoked and 36 had smoked at least 10 cigarettes per day for ‎at least one year. Hemolysate superoxide dismutase (Cu-Zn SOD, glutathione peroxidase (GSH-Px and ‎catalase (CAT activities were measured using spectrophotometer. Plasma copper, zinc and selenium concentrations were determined ‎using atomic absorption spectrophotometer. Plasma iron concentration was determined by colorimetric ‎method. We found that erythrocyte Cu-Zn SOD activity was significantly higher in tobacco smokers ‎compared with non-smokers (1294 ± 206.7 U/gHb in smokers vs. 1121.6 ± 237.8 U/gHb in non-‎smokers, P < 0.01. While plasma selenium concentration was significantly lower in tobacco ‎smokers (62.7±14.8 μg/L in smokers vs. 92.1 ± 17.5 μg/L in non-smokers, P < 0.01, there were no significant ‎differences in erythrocyte GSH-Px and CAT activities and plasma copper, zinc and iron concentrations between the two groups. ‎It seems that cigarette smoking can alter antioxidative enzymes activity and plasma concentration of some trace elements.

  1. Decreased plasma concentrations of brain-derived neurotrophic factor (BDNF) in patients with functional hypothalamic amenorrhea.

    Science.gov (United States)

    Podfigurna-Stopa, Agnieszka; Casarosa, Elena; Luisi, Michele; Czyzyk, Adam; Meczekalski, Blazej; Genazzani, Andrea Riccardo

    2013-09-01

    Functional hypothalamic amenorrhea (FHA) is a non organic, secondary amenorrhea related to gonadotropin-releasing hormone pulsatile secretion impairment. Brain-derived neurotrophic factor (BDNF), a member of the neurotrophin family of survival-promoting molecules, plays an important role in the growth, development, maintenance and function of several neuronal systems. The aim of the study was the evaluation of plasma BDNF concentrations in patients with the diagnosis of FHA. We studied 85 subjects diagnosed with FHA who were compared with 10 healthy, eumenorrheic controls with normal body mass index. Plasma BDNF and serum luteinizing hormone, follicle-stimulating hormone and estradiol (E2) concentrations were measured by immunoenzymatic method (enzyme-linked immunosorbent assay). Significantly lower concentration of plasma BDNF was found in FHA patients (196.31 ± 35.26 pg/ml) in comparison to healthy controls (407.20 ± 25.71 pg/ml; p < 0.0001). In the control group, there was a strong positive correlation between plasma BDNF and serum E2 concentrations (r = 0.92, p = 0.0001) but in FHA group it was not found. Role of BDNF in FHA is not yet fully understood. There could be found studies concerning plasma BDNF concentrations in humans and animals in the literature. However, our study is one of the first projects which describes decreased plasma BDNF concentration in patients with diagnosed FHA. Therefore, further studies on BDNF in FHA should clarify the role of this peptide.

  2. Neutron measurement techniques for tokamak plasmas

    International Nuclear Information System (INIS)

    Jarvis, O.N.

    1994-01-01

    The present article reviews the neutron measurement techniques that are currently being applied to the study of tokamak plasmas. The range of neutron energies of primary interest is limited to narrow bands around 2.5 and 14 MeV, and the variety of measurements that can be made for plasma diagnostic purposes is also restricted. To characterize the plasma as a neutron source, it is necessary only to measure the total neutron emission, the relative neutron emissivity as a function of position throughout the plasma, and the energy spectra of the emitted neutrons. In principle, such measurements might be expected to be relatively easy. That this is not the case is, in part, attributable to practical problems of accessibility to a harsh environment but is mostly a consequence of the time-scale on which the measurements have to be made and of the wide range of neutron emission intensities that have to be covered: for tokamak studies, the time-scale is of the order of 1 to 100 ms and the neutron intensity ranges from 10 12 to 10 19 s -1 . (author)

  3. Perioperative plasma concentrations of stable nitric oxide products are predictive of cognitive dysfunction after laparoscopic cholecystectomy.

    LENUS (Irish Health Repository)

    Iohom, G

    2012-02-03

    In this study our objectives were to determine the incidence of postoperative cognitive dysfunction (POCD) after laparoscopic cholecystectomy under sevoflurane anesthesia in patients aged >40 and <85 yr and to examine the associations between plasma concentrations of i) S-100beta protein and ii) stable nitric oxide (NO) products and POCD in this clinical setting. Neuropsychological tests were performed on 42 ASA physical status I-II patients the day before, and 4 days and 6 wk after surgery. Patient spouses (n = 13) were studied as controls. Cognitive dysfunction was defined as deficit in one or more cognitive domain(s). Serial measurements of serum concentrations of S-100beta protein and plasma concentrations of stable NO products (nitrate\\/nitrite, NOx) were performed perioperatively. Four days after surgery, new cognitive deficit was present in 16 (40%) patients and in 1 (7%) control subject (P = 0.01). Six weeks postoperatively, new cognitive deficit was present in 21 (53%) patients and 3 (23%) control subjects (P = 0.03). Compared with the "no deficit" group, patients who demonstrated a new cognitive deficit 4 days postoperatively had larger plasma NOx at each perioperative time point (P < 0.05 for each time point). Serum S-100beta protein concentrations were similar in the 2 groups. In conclusion, preoperative (and postoperative) plasma concentrations of stable NO products (but not S-100beta) are associated with early POCD. The former represents a potential biochemical predictor of POCD.

  4. Plasma Apelin Concentrations in Patients With Polyuria-Polydipsia Syndrome.

    Science.gov (United States)

    Urwyler, Sandrine Andrea; Timper, Katharina; Fenske, Wiebke; de Mota, Nadia; Blanchard, Anne; Kühn, Felix; Frech, Nica; Arici, Birsen; Rutishauser, Jonas; Kopp, Peter; Stettler, Christoph; Müller, Beat; Katan, Mira; Llorens-Cortes, Catherine; Christ-Crain, Mirjam

    2016-05-01

    Apelin and arginine vasopressin are antagonists in the regulation of body fluid and osmotic homeostasis. There are no data about apelin levels in patients with polyuria-polydipsia syndrome (PPS). To investigate plasma apelin levels and plasma apelin to copeptin ratios in patients with PPS and healthy volunteers using copeptin as a surrogate marker for arginine vasopressin. We included 41 patients with PPS in this post hoc analysis of a prospective study performed in tertiary care hospitals in Switzerland and Germany and 113 healthy volunteers as a control group. Plasma apelin and copeptin levels were measured in 15 patients with complete central diabetes insipidus (DI), seven patients with complete nephrogenic DI, 19 patients with primary polydipsia (PP), and 113 healthy volunteers. Plasma apelin levels were highest in patients with complete nephrogenic DI (413 pmol/L; interquartile range, 332-504 pmol/L; P = .01) and lower in patients with PP (190 [172-215] pmol/L; P .9) was similar to healthy volunteers (57 [37-102] pmol/pmol). In contrast, the apelin to copeptin ratio was higher in patients with complete central DI (89 [73-135] pmol/pmol; P = .02) and lower in patients with complete nephrogenic DI (7 [6-10] pmol/pmol; P < .001) compared to healthy volunteers. In PP, normal plasma apelin to copeptin ratio attests a normal water homeostasis. In contrast, in patients with central or nephrogenic DI, the increased or decreased apelin to copeptin ratio, respectively, reflects a disturbed osmotic and body fluid homeostasis.

  5. Athoropometric measurements and plasma proteins in protein ...

    African Journals Online (AJOL)

    Athoropometric measurements and plasma proteins in protein energy malnutrition. MH Etukudo, EO Agbedana, OO Akinyinka, BOA Osifo. Abstract. No Abstract. Global Journal of Medical Sciences Vol. 5(1) 2006: 7-11. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD ...

  6. Childhood obesity treatment; Effects on BMI SDS, body composition, and fasting plasma lipid concentrations.

    Science.gov (United States)

    Nielsen, Tenna Ruest Haarmark; Fonvig, Cilius Esmann; Dahl, Maria; Mollerup, Pernille Maria; Lausten-Thomsen, Ulrik; Pedersen, Oluf; Hansen, Torben; Holm, Jens-Christian

    2018-01-01

    The body mass index (BMI) standard deviation score (SDS) may not adequately reflect changes in fat mass during childhood obesity treatment. This study aimed to investigate associations between BMI SDS, body composition, and fasting plasma lipid concentrations at baseline and during childhood obesity treatment. 876 children and adolescents (498 girls) with overweight/obesity, median age 11.2 years (range 1.6-21.7), and median BMI SDS 2.8 (range 1.3-5.7) were enrolled in a multidisciplinary outpatient treatment program and followed for a median of 1.8 years (range 0.4-7.4). Height and weight, body composition measured by dual-energy X-ray absorptiometry, and fasting plasma lipid concentrations were assessed at baseline and at follow-up. Lipid concentrations (total cholesterol (TC), low-density lipoprotein (LDL), high-density lipoprotein (HDL), non-HDL, and triglycerides (TG)) were available in 469 individuals (264 girls). Linear regressions were performed to investigate the associations between BMI SDS, body composition indices, and lipid concentrations. At baseline, BMI SDS was negatively associated with concentrations of HDL (p = 6.7*10-4) and positively with TG (p = 9.7*10-6). Reductions in BMI SDS were associated with reductions in total body fat percentage (pobesity during multidisciplinary childhood obesity treatment are accompanied by improvements in body composition and fasting plasma lipid concentrations. Even in individuals increasing their BMI SDS, body composition and lipid concentrations may improve.

  7. Concentrations of Nicotinamide in Plasma by RP-HPLC With Fluorescence Detection

    Directory of Open Access Journals (Sweden)

    Pan Zhipeng

    2016-01-01

    Full Text Available The purpose of this study is to establish a new method for detecting nicotinamide concentration in plasma. In the experiment, the high performance liquid chromatography (HPLC method was used, with a fluorescence detector. The nicotinamide in the plasma was first converted to N1- methylnicotinamide, then reacted with acetophenone under certain conditions to produce fluorescent derivatives for testing. The method is a kind of highly sensitive detection, of which the lower limit is 10 ng/mL, the recovery rate is between 92.75% and 105.13%, and the relative standard deviation (RSD is between 3.76% and 4.43%. The results showed that this measurement method is accurate, sensitive and rapid. It meets the requirements of the experiment, and applies to the detection of nicotinamide concentration in plasma.

  8. Intake of whole grains and vegetables determines the plasma enterolactone concentration of Danish women.

    Science.gov (United States)

    Johnsen, Nina F; Hausner, Helene; Olsen, Anja; Tetens, Inge; Christensen, Jane; Knudsen, Knud Erik Bach; Overvad, Kim; Tjønneland, Anne

    2004-10-01

    The mammalian lignan enterolactone (ENL), which is produced from dietary plant-lignan precursors by the intestinal microflora, may protect against breast cancer and other hormone-dependent cancers. This cross-sectional study examined which variables related to diet and lifestyle were associated with high plasma concentrations of ENL in Danish postmenopausal women. Plasma ENL was measured by time-resolved fluoroimmunoassay in 857 Danish women aged 50-64 y who participated in a prospective cohort study. Diet was assessed using a semiquantitative FFQ, and background information on lifestyle was collected using a self-administered questionnaire. Multiple analyses of covariance were completed in two steps. The median plasma ENL concentration was 27 nmol/L (range 0-455 nmol/L). In covariance analyses, positive associations were found between consumption of cereals, vegetables, and beverages and plasma ENL concentration. When analyzing subgroups of these food groups, the associations were confined to whole-grain products, cabbage, leafy vegetables, and coffee. For fat and the nondietary variables, negative associations between BMI, smoking, and frequency of bowel movements and plasma ENL concentration were observed. These data show that foods high in ENL precursors are associated with high concentrations of ENL. Furthermore, smoking, frequent bowel movements, and consumption of fat seems to have a negative affect on the ENL concentration. In conclusion, whole grains and vegetables are the most important dietary providers of plant lignans for the concentration of ENL in Danish postmenopausal women, and if ENL is found to protect against cancer or heart disease, the intake of whole grains and vegetables should be increased.

  9. Effects of fasting on plasma catecholamine, corticosterone and glucose concentrations under basal and stress conditions in individual rats

    NARCIS (Netherlands)

    de Boer, S.F.; Koopmans, S.J.; Slangen, J L; Van der Gugten, J

    Plasma noradrenaline (NA), adrenaline (A), corticosterone (CS) and glucose concentrations were determined in blood sampled via a cardiac catheter from freely moving male rats under ad lib fed and 24 hr food deprived conditions using a repeated measures within-subject design. Resting plasma NA and

  10. Diffraction tomography for plasma refractive index measurements

    International Nuclear Information System (INIS)

    Howard, J.; Nazikian, R.; Sharp, L.E.

    1989-01-01

    Measurement of the properties of probing beams of coherent electromagnetic radiation yields essential information about the line of sight integrated plasma refractive index. Presented is a scalar diffraction treatment of forward angle scattering plasma diagnostics based on the diffraction projection theorem first presented by E. Wolf in 1969. New results are obtained for near field scattering from probing Gaussian beams and it is demonstrated that the effects of diffraction need to be addressed for tomographic inversion of near field scattering and interferometry data. 33 refs., 10 figs

  11. Plasma brain natriuretic peptide concentrations in patients with valvular heart disease

    Science.gov (United States)

    Stewart, Ralph A; Lee, Mildred; Gabriel, Ruvin; Van Pelt, Niels; Newby, David E; Kerr, Andrew J

    2016-01-01

    Objective Plasma brain natriuretic peptide (BNP) concentrations predict prognosis in patients with valvular heart disease (VHD), but it is unclear whether this directly relates to disease severity. We assessed the relationship between BNP and echocardiographic measures of disease severity in patients with VHD. Methods Plasma BNP concentrations were measured in patients with normal left ventricular (LV) systolic function and isolated VHD (mitral regurgitation (MR), n=33; aortic regurgitation (AR), n=39; aortic stenosis (AS), n=34; mitral stenosis (MS), n=30), and age-matched and sex-matched controls (n=39) immediately prior to exercise stress echocardiography. Results Compared with controls, patients with VHD had elevated plasma BNP concentrations (MR median 35 (IQR 23–52), AR 34 (22–45), AS 31 (22–60), MS 58 (34–90); controls 24 (16–33) pg/mL; p<0.01 for all). LV end diastolic volume index varied by valve lesion; (MR (mean 77±14), AR (91±28), AS (50±17), MS (43±11), controls (52±13) mL/m2; p<0.0001). There were no associations between LV volume and BNP. Left atrial (LA) area index varied (MR (18±4 cm2/m2), AR (12±2), AS (11±3), MS (19±6), controls (11±2); p<0.0001), but correlated with plasma BNP concentrations: MR (r=0.42, p=0.02), MS (r=0.86, p<0.0001), AR (r=0.53, p=0.001), AS (r=0.52, p=0.002). Higher plasma BNP concentrations were associated with increased pulmonary artery pressure and reduced exercise capacity. Despite adverse cardiac remodelling, 81 (60%) patients had a BNP concentration within the normal range. Conclusions Despite LV remodelling, plasma BNP concentrations are often normal in patients with VHD. Conversely, mild elevations of BNP occur with LA dilatation in the presence of normal LV. Plasma BNP concentrations should be interpreted with caution when assessing patients with VHD. PMID:27175283

  12. Absorption kinetics and steady-state plasma concentrations of theophylline following therapeutic doses of two sustained-release preparations

    DEFF Research Database (Denmark)

    Andersen, O; Nielsen, M K; Eriksen, P B

    1983-01-01

    Ten healthy volunteers received two sustained-release preparations as a single and multiple dose regimen in an open crossover study. Plasma theophylline concentrations were measured by an enzyme immunoassay. The limited fluctuation of the theophylline levels at steady state, with twice daily...... formulation, whereas this was not the case for the other (r = 0.27 and 0.49). The daily dose necessary to keep the plasma concentration within the therapeutic range of 55-110 mumole/liter varied from 7.9 to 22.9 mg/kg. Only mild side effects were recorded, but they were not correlated to the plasma...... theophylline concentration....

  13. Correlation measurements for fusion plasma diagnostics

    International Nuclear Information System (INIS)

    Pazsit, I.

    1995-01-01

    A list of a few methods for plasma diagnostics via fluctuations (noise) analysis of random (both temporally and spatially) system parameters is reviewed. Analogy is drawn with certain noise analysis methods, used in the diagnostics of fission reactors. These methods have been applied also to fusion measurements to some extent. However, the treatment of fusion plasma fluctuations is dominated by an approach that allows for temporal randomness, but assumes periodicity in space. This approach suits well a large class of phenomena such as magnetic fluctuations (MHD effects), but is much less suited to treat localised effects such as turbulence and density fluctuations. This paper discusses the potentials of the former approach, i.e. ordinary noise analysis methods of non-periodic variables in fusion plasma diagnostics. A new recommendation is to use the crossed beam correlation analysis of soft X-ray signals for determining the local short-range correlations in the plasma and to perform a systematic exploration of the plasma spatial correlation structure with that and other methods. 16 refs, 7 figs

  14. Conjoint regulation of glucagon concentrations via plasma insulin and glucose in dairy cows.

    Science.gov (United States)

    Zarrin, M; Wellnitz, O; Bruckmaier, R M

    2015-04-01

    Insulin and glucagon are glucoregulatory hormones that contribute to glucose homeostasis. Plasma insulin is elevated during normoglycemia or hyperglycemia and acts as a suppressor of glucagon secretion. We have investigated if and how insulin and glucose contribute to the regulation of glucagon secretion through long term (48 h) elevated insulin concentrations during simultaneous hypoglycemia or euglycemia in mid-lactating dairy cows. Nineteen Holstein dairy cows were randomly assigned to 3 treatment groups: an intravenous insulin infusion (HypoG, n = 5) to decrease plasma glucose concentrations (2.5 mmol/L), a hyperinsulinemic-euglycemic clamp to study effects of insulin at simultaneously normal glucose concentrations (EuG, n = 6) and a 0.9% saline infusion (NaCl, n = 8). Plasma glucose was measured at 5-min intervals, and insulin and glucose infusion rates were adjusted accordingly. Area under the curve of hourly glucose, insulin, and glucagon concentrations on day 2 of infusion was evaluated by analysis of variance with treatments as fixed effect. Insulin infusion caused an increase of plasma insulin area under the curve (AUC)/h in HypoG (41.9 ± 8.1 mU/L) and EuG (57.8 ± 7.8 mU/L) compared with NaCl (13.9 ± 1.1 mU/L; P insulin infusion induces elevated glucagon concentrations during hypoglycemia, although the same insulin infusion reduces glucagon concentrations at simultaneously normal glucose concentrations. Thus, insulin does not generally have an inhibitory effect on glucagon concentrations. If simultaneously glucose is low and insulin is high, glucagon is upregulated to increase glucose availability. Therefore, insulin and glucose are conjoint regulatory factors of glucagon concentrations in dairy cows, and the plasma glucose status is the key factor to decide if its concentrations are increased or decreased. This regulatory effect can be important for the maintenance of glucose homeostasis if insulin secretion is upregulated by other factors than high

  15. Quadrature interferometry for plasma density measurements

    International Nuclear Information System (INIS)

    Warthen, B.J.; Shlachter, J.S.

    1995-01-01

    A quadrature interferometer has been used routinely in several pulsed power experiments to measure the line-averaged electron density. The optical source is a 30 mW, continuous wave Nd-YAG laser operating at 1,300 nm. The light is coupled directly to an optical fiber and split into reference and scene beams with a fiber splitter. The scene beam is transported to and from the plasma using single mode optical fibers up to 100 m in length. To simplify alignment through the plasma, the authors have used GRIN lenses on both the launch and receive sides of the single pass transmission diagnostic where this is possible. The return beam passes through a half-wave plate which is used to compensate for polarization rotation associated with slow (hour) time scale drift in the single mode fibers. The reference beam is sent through a quarter-wave plate to produce circular polarization; mixing of the reference and scene beams is accomplished using a non-polarizing beam splitter, and the interference signals are focused into additional fibers which relay the light to fast photodiodes. The quadrature optics allow for an unambiguous determination of the slope of the density changes at inflection points. All of the beam processing optics are located on a stable optical table which is remote and protected from the experiment. Final setup of the interferometer is facilitated by looking at the Lissajous figure generated from the two quadrature components. The authors have used this interferometer to diagnose the background density in the Pegasus-II power flow channel, to study the plasma plume generated in foil implosion experiments, to measure the plasma blowoff during implosions, and to understand the plasma formation mechanism in a fusion target plasma system

  16. Measurement of interstitial cetirizine concentrations in human skin

    DEFF Research Database (Denmark)

    Petersen, Lars Jelstrup; Church, M K; Rihoux, J P

    1999-01-01

    BACKGROUND: The purpose of the present study was to measure the concentrations of cetirizine in the extracellular water compartment in intact human skin and assess simultaneously inhibition of histamine-induced wheal and flare reactions. METHODS: Skin cetirizine levels were collected...... by the microdialysis technique and analyzed by high-pressure liquid chromatography with mass spectrometry detection. Skin levels in 20 subjects were compared to plasma levels for 4 h after a single oral dose of 10 or 20 mg of cetirizine. Skin prick tests were performed with histamine 100 mg/ml. RESULTS: Plasma...... cetirizine levels increased within 30 min to reach peak values of 315+/-10 and 786+/-45 ng/ml 90-120 min after administration of 10 and 20 mg of cetirizine. This was followed by a slow decline. In the skin, dialysate cetirizine levels (non-protein-bound fraction only) peaked at 1.6+/-0.1 and 2.4+/-0.3 ng...

  17. Sigma-1 receptor concentration in plasma of patients with late-life depression: a preliminary study

    Directory of Open Access Journals (Sweden)

    Shimizu H

    2013-12-01

    Full Text Available Hideyuki Shimizu,1 Minoru Takebayashi,2 Masayuki Tani,1 Hiroaki Tanaka,1 Bun Yamagata,1 Kenzo Kurosawa,1 Hiroki Yamada,1 Mitsugu Hachisu,3 Kazue Hisaoka-Nakashima,2 Mami Okada-Tsuchioka,2 Masaru Mimura,4 Akira Iwanami11Department of Neuropsychiatry, Showa University School of Medicine, Tokyo, Japan; 2Department of Psychiatry and Institute for Clinical Research, National Hospital Organization Kure Medical Center, Kure, Japan; 3Department of Clinical Psychopharmacy, Pharmacy School, Showa University, Tokyo, Japan; 4Department of Neuropsychiatry, Keio University School of Medicine, Tokyo, JapanBackground: Recently, the sigma-1 receptor has been shown to play a significant role in the neural transmission of mood by regulating N-methyl-D-aspartate receptors. Additionally, the sigma-1 receptor has been reported to influence cognitive functions including learning and memory. In this study, we measured plasma sigma-1 receptor concentrations before and after antidepressant treatment in patients with late-life major depressive disorder (MDD and explored whether changes in depressive status are related to sigma-1 receptor concentrations.Methods: The study participants were 12 subjects with late-life MDD diagnosed according to the criteria of the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition. All of the participants were over 60 years old. Immediately prior to and 8 weeks after the start of treatment, sigma-1 receptor concentration and mental status, including depressive symptoms (Hamilton Depression Rating Scale; HAM-D, were measured. Treatment for depression was performed according to a developed algorithm based on the choice of treatments. We examined the association between changes in sigma-1 receptor concentration and HAM-D scores during antidepressant treatment. For the measurement of plasma sigma-1 receptor concentration, blood plasma samples were separated by sodium dodecyl sulfate polyacrylamide gel electrophoresis. Western

  18. Electric field measurements in moving ionization fronts during plasma breakdown

    NARCIS (Netherlands)

    Wagenaars, E.; Bowden, M.D.; Kroesen, G.M.W.

    2006-01-01

    We have performed time-resolved, direct measurements of electric field strengths in moving ionization fronts during the breakdown phase of a pulsed plasma. Plasma breakdown, or plasma ignition, is a highly transient process marking the transition from a gas to a plasma. Some aspects of plasma

  19. Anti-tumor Effects of Plasma Activated Media and Correlation with Hydrogen Peroxide Concentration

    Science.gov (United States)

    Laroussi, Mounir; Mohades, Soheila; Barekzi, Nazir; Maruthamuthu, Venkat; Razavi, Hamid

    2016-09-01

    Plasma activated media (PAM) can induce death in cancer cells. In our research, PAM is produced by exposing liquid culture medium to a helium plasma pencil. Reactive oxygen and nitrogen species in the aqueous state are known factors in anti-tumor effects of PAM. The duration of plasma exposure determines the concentrations of reactive species produced in PAM. Stability of the plasma generated reactive species and their lifetime depend on parameters such as the chemical composition of the medium. Here, a complete cell culture medium was employed to make PAM. Later, PAM was used to treat SCaBER cancer cells either as an immediate PAM (right after exposure) or as an aged-PAM (after storage). SCaBER (ATCC®HTB-3™) is an epithelial cell line from a human bladder with the squamous carcinoma disease. A normal epithelial cell line from a kidney tissue of a dog - MDCK (ATCC®CCL-34™) - was used to analyze the selective effect of PAM. Correspondingly, we measured the concentration of hydrogen peroxide- as a stable species with biological impact on cell viability- in both immediate PAM and aged-PAM. In addition, we report on the effect of serum supplemented in PAM on the H2O2 concentration measured by Amplex red assay kit. Finally, we evaluate the effects of PAM on growth and morphological changes in MDCK cells using fluorescence microscopy.

  20. Postprandial changes in plasma acylcarnitine concentrations as markers of fatty acid flux in overweight and obesity.

    Science.gov (United States)

    Ramos-Roman, Maria A; Sweetman, Lawrence; Valdez, Maressa J; Parks, Elizabeth J

    2012-02-01

    This study determined whether reductions in postprandial plasma nonesterified fatty acid (FFA) flux would lead to reductions in plasma acylcarnitine (AC) concentrations. Plasma AC was measured by liquid chromatography with tandem mass spectrometry in the fasting state and over 6 hours after a high-fat (50% energy) meal was fed to 16 overweight and obese subjects with a wide range of insulin sensitivities. Body composition was measured by dual-energy x-ray absorptiometry; insulin sensitivity by insulin-modified, frequently sampled intravenous glucose tolerance test; substrate oxidation by indirect calorimetry; blood metabolite and hormone concentrations biochemically; and fatty acid flux by using stable isotope tracers. Lean body mass and fasting fat oxidation correlated positively (r > 0.522, P 0.515, P Conditions that impact fatty acid flux contribute to the control of postprandial plasma AC concentrations. These data underscore the need for a better understanding of postprandial fatty acid oxidation and dietary fat delivery in the setting of adipose insulin resistance to determine how postprandial lipemia contributes to chronic disease risk. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. IFCC guideline for sampling, measuring and reporting ionized magnesium in plasma

    DEFF Research Database (Denmark)

    Rayana, M.C. Ben; Burnett, R.W.; Covington, A.K.

    2008-01-01

    Analyzers with ion-selective electrodes (ISEs) for ionized magnesium (iMg) should yield comparable and unbiased results for iMg. This IFCC guideline on sampling, measuring and reporting iMg in plasma provides a prerequisite to achieve this goal [in this document, "plasma" refers to circulating...... plasma and the forms in which it is sampled, namely the plasma phase of anticoagulated whole blood (or "blood"), plasma separated from blood cells, or serum]. The guideline recommends measuring and reporting ionized magnesium as a substance concentration relative to the substance concentration...... of magnesium in primary aqueous calibrants with magnesium, sodium, and calcium chloride of physiological ionic strength. The recommended name is "the concentration of ionized magnesium in plasma". Based on this guideline, results will be approximately 3% higher than the true substance concentration and 4...

  2. Lutein Supplementation Increases Breast Milk and Plasma Lutein Concentrations in Lactating Women and Infant Plasma Concentrations but Does Not Affect Other Carotenoids 1 2 3

    OpenAIRE

    Sherry, Christina L.; Oliver, Jeffery S.; Renzi, Lisa M.; Marriage, Barbara J.

    2014-01-01

    Lutein is a carotenoid that varies in breast milk depending on maternal intake. Data are lacking with regard to the effect of dietary lutein supplementation on breast milk lutein concentration during lactation and subsequent plasma lutein concentration in breast-fed infants. This study was conducted to determine the impact of lutein supplementation in the breast milk and plasma of lactating women and in the plasma of breast-fed infants 2–3 mo postpartum. Lutein is the dominant carotenoid in t...

  3. Portable method of measuring gaseous acetone concentrations.

    Science.gov (United States)

    Worrall, Adam D; Bernstein, Jonathan A; Angelopoulos, Anastasios P

    2013-08-15

    Measurement of acetone in human breath samples has been previously shown to provide significant non-invasive diagnostic insight into the control of a patient's diabetic condition. In patients with diabetes mellitus, the body produces excess amounts of ketones such as acetone, which are then exhaled during respiration. Using various breath analysis methods has allowed for the accurate determination of acetone concentrations in exhaled breath. However, many of these methods require instrumentation and pre-concentration steps not suitable for point-of-care use. We have found that by immobilizing resorcinol reagent into a perfluorosulfonic acid polymer membrane, a controlled organic synthesis reaction occurs with acetone in a dry carrier gas. The immobilized, highly selective product of this reaction (a flavan) is found to produce a visible spectrum color change which could measure acetone concentrations to less than ppm. We here demonstrate how this approach can be used to produce a portable optical sensing device for real-time, non-invasive acetone analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Plasma oxytocin concentrations during late pregnancy and parturition in the dog.

    Science.gov (United States)

    Klarenbeek, M; Okkens, A C; Kooistra, H S; Mol, J A; M M Bevers; Taverne, M A M

    2007-11-01

    While oxytocin is widely used in the treatment of dystocia in dogs, there is little information about its secretion before and during normal unassisted whelping. We therefore measured plasma oxytocin concentrations during late pregnancy and the expulsive stage of parturition. Blood samples were collected from eight dogs at 3-min intervals during a 42-min period between the 2nd and 14th day before whelping and during parturition after the birth of 1-3 pups. The litters consisted of 5-15 pups and the progression of the expulsive stage was linear and nearly parallel in the eight bitches. The overall mean (+/-S.D.) plasma oxytocin concentration during late pregnancy was 3.6+/-2.1pg/ml. Mean values in individual dogs ranged from 1.2 to 7.4 pg/ml, but the intra-animal variation was rather small. During the expulsive stage the overall mean (+/-S.D.) plasma oxytocin concentration was 12.9+/-13.9 pg/ml, with mean values in individual dogs ranging from 3.5 to 46 pg/ml. The mean area under the oxytocin curve for parturient dogs was significantly higher (Pdogs. During the expulsive stage, the peak plasma oxytocin level in individual dogs ranged between 10 and 117 pg/ml. In six of the eight dogs a pup was born during blood collection and in five of these animals the plasma oxytocin concentration increased temporarily during periods of abdominal straining and expulsion. However, straining efforts and expulsion were not consistently associated with a rise in the circulating oxytocin level. It is concluded that in the dog plasma oxytocin levels are higher and more variable during the expulsive stage of parturition than during late pregnancy. Interrelationships between the secretion pattern of oxytocin, the level of uterine contractility, and the progress of fetal expulsion in dogs need further exploration.

  5. The effects of therapeutic concentrations ofamisulpride andrisperidone on human plasma lipid peroxidation – invitro studies

    Directory of Open Access Journals (Sweden)

    Anna Dietrich-Muszalska

    2011-09-01

    Full Text Available Introduction: Antipsychotics may in different ways affect the oxidative stress measured by plasma lipid peroxidation. Probably some of them may intensify the oxidative balance disturbances occurring in schizophrenia. The effects of amisulpride and risperidone on redox processes are not known sufficiently yet. Aim of the study: Establishment of the effects of amisulpride and risperidone on human plasma lipid peroxidation measured by determination of the level of thiobarbituric acid-reactive substances (TBARS, in vitro. Material and methods: Blood for the studies was collected from healthy volunteers (aged 24-26 years for ACD solution. Active substances of the examined drugs were dissolved in 0.01% dimethylsulfoxide (DMSO to the final concentrations (of amisulpride 578 ng/ml and risperidone 64 ng/ml and incubated with plasma for 1 and 24 hours at 37ºC. For each experiment the control samples of plasma with DMSO (without the drug were performed. The lipid peroxidation level was measured in plasma by determining the TBARS concentration, using the spectrophotometric method (acc. to Rice-Evans, 1991. The results were analysed using the following statistical methods: the paired Student t-test and ANOVA II variance analysis and NIR test (StatSoft Inc., Statistica v. 6.0. Results: The ANOVA II variance analysis indicated significant differences in the effects of both drugs on TBARS level (F=4.26; df=2, p0.05. Conclusion: Amisulpride and risperidone in concentrations corresponding to doses recommended for treatment of acute episode of schizophrenia do not induce oxidative stress measured by lipid peroxidation. Unlike risperidone, amisulpride exhibits antioxidative effects.

  6. Apparatus for measuring a concentration of radioactivity

    International Nuclear Information System (INIS)

    Tabuchi, H.; Ogushi, A.

    1978-01-01

    Disclosed is an apparatus for measuring concentration of radioactivity in a fluid circulating in a cooling system or a disposal system, etc., of a nuclear power plant (e.g. coolant), the apparatus having a plurality of sampling tubes with different diameters depending on the intensities of radioactivity, and the sampling tubes having valves for switching from one fluid to another fluid. The sampling tubes are connected to the system to a discharge pipe, and are disposed in the proximity of a radiation detector adapted to issue a signal representative of radiation. The issued signal is supplied to a multichannel pulse height analyzer and a data processing system providing an indication of the concentrations of radioactivities for respective radionuclides

  7. Simultaneous measurement of 3 fluctuating plasma parameters

    International Nuclear Information System (INIS)

    Carlson, A.; Giannone, L.

    1991-01-01

    Langmuir triple probes can provide simultaneous measurements of n e , T e and V pl with good temporal and spatial resolution, and therefore are especially suited to detailed investigations of plasma turbulence in the scrape-off-layer. Unfortunately, the finite tip separation coupled with the fluctuating gradients prevents a simple interpretation of the results. We have developed a method using, essentially, two or more triple probes, which allows a good estimate of the three plasma parameters and their spatial derivatives at each point of time (assuming tip separation is much less than correlation length and dimensionless fluctuation levels are much less than unity). In particular, we can unambiguously measure the temperature fluctuations and the turbulent particle and heat flux. (author) 1 fig

  8. Simultaneous measurement of 3 fluctuating plasma parameters

    International Nuclear Information System (INIS)

    Carlson, A.; Giannone, L.

    1991-01-01

    Langmuir triple probes can provide simultaneous measurements of n e , T e , and V pl with good temporal and spatial resolution, and therefore are especially suited to detailed investigations of plasma turbulence in the scrape-off-layer. Unfortunately, the finite tip separation coupled with the fluctuating gradients prevents a simple interpretation of the results. We have developed a method using, essentially, two or more triple probes, which allows a good estimate of the three plasma parameters and their spatial derivatives at each point of time (assuming tip separation is much less than correlation length and dimensionless fluctuation levels are much less than unity). In particular, we can unambiguously measure the temperature fluctuations and the turbulent particle and heat flux. (orig.)

  9. Simultaneous measurement of 3 fluctuating plasma parameters

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, A; Giannone, L. (Max-Planck-Institut fuer Plasmaphysik, Garching (Germany))

    1991-01-01

    Langmuir triple probes can provide simultaneous measurements of n[sub e], T[sub e] and V[sub pl] with good temporal and spatial resolution, and therefore are especially suited to detailed investigations of plasma turbulence in the scrape-off-layer. Unfortunately, the finite tip separation coupled with the fluctuating gradients prevents a simple interpretation of the results. We have developed a method using, essentially, two or more triple probes, which allows a good estimate of the three plasma parameters and their spatial derivatives at each point of time (assuming tip separation is much less than correlation length and dimensionless fluctuation levels are much less than unity). In particular, we can unambiguously measure the temperature fluctuations and the turbulent particle and heat flux. (author) 1 fig.

  10. Plasma measurements with surface barrier detectors

    International Nuclear Information System (INIS)

    Futch, A.H. Jr.; Bradley, A.E.

    1969-01-01

    A surface barrier detector system for measuring the loss rate of protons from a hydrogen plasma and their energy spectrum is described. A full width at half maximum (FWHM) resolution of 1.4 keV for 15-keV hydrogen atoms was obtained using a selected detector having a sensitive area of 3 mm 2 and a depletion depth of 700 microns

  11. Thomson scattering measurements in atmospheric plasma jets

    International Nuclear Information System (INIS)

    Gregori, G.; Schein, J.; Schwendinger, P.; Kortshagen, U.; Heberlein, J.; Pfender, E.

    1999-01-01

    Electron temperature and electron density in a dc plasma jet at atmospheric pressure have been obtained using Thomson laser scattering. Measurements performed at various scattering angles have revealed effects that are not accounted for by the standard scattering theory. Differences between the predicted and experimental results suggest that higher order corrections to the theory may be required, and that corrections to the form of the spectral density function may play an important role. copyright 1999 The American Physical Society

  12. Ion Distribution Measurement In Plasma Focus

    International Nuclear Information System (INIS)

    Suryadi; Sunardi; Usada, Widdi; Purwadi, Agus; Zaenuri, Akhmad

    1996-01-01

    Measurement of the Argon ion distribution in plasma focus by using Faraday cup has been done. The intensity of ion beam followed the I Rn rule, n=1,02. In the operation condition of 0,8 mbar and 12,5 kV the current sheath spen 2.2 to 2.4 μsecond in the rundown phase. Cu ion was also been observed in the Faraday cup

  13. Measurements of radon concentrations in dwelling houses

    International Nuclear Information System (INIS)

    Birkholz, W.; Klink, T.

    1993-01-01

    Radon and its daughter products gain in importance in health protection and radiation safety. Especially in the southern region of Saxony radon concentrations in dwellings may be high by former silver and uranium mines. We found radon contents of about 20.000 Bq/m 3 in dwellings. To redevelop such houses it is necessary to know intrude path of radon. In present work we studied different measuring systems, active and passive detectors, short and long term integrating devices. By means of investigation of radon sources several redeveloping methods are rates as well from radiological as from civil engineering point of view. (author)

  14. Energy conversion and concentration in a high-current gaseous discharge: Dense plasma spheromak in plasma focus experiments

    International Nuclear Information System (INIS)

    Kukushkin, A.B.; Rantsev-Kartinov, V.A.; Terentiev, A.R.

    1995-01-01

    Experimental results are presented which verify the possibility of the self-generated transformation of the magnetic field in plasma focus discharges to give a closed, spheromak-like magnetic configuration (SLMC). The energy conversion mechanism suggests a possibility of further concentrating the plasma power density by means of natural compressing the SLMC-trapped plasma by the residual magnetic field of the plasma focus discharge

  15. Salivary pH as a marker of plasma adiponectin concentrations in Women.

    Science.gov (United States)

    Tremblay, Monique; Loucif, Yacine; Methot, Julie; Brisson, Diane; Gaudet, Daniel

    2012-02-03

    Plasma adiponectin is a significant correlate of the pro-inflammatory cardiometabolic risk profile associated with obesity and type 2 diabetes. Salivary pH is influenced by several cardiometabolic risk components such as inflammation, oxidation and numerous oral and systemic health modulators, including the menopausal status. This study aimed to assess the association between plasma adiponectin concentrations and salivary pH in women according to the menopausal status. Unstimulated saliva collection was performed in 151 Caucasian women of French-Canadian origin (53 premenopausal women (PMW) and 98 menopausal women (MW)). Student's t test, ANOVA and linear regression models were used to assess the association between plasma adiponectin concentrations and salivary pH. Plasma adiponectin levels increased as a function of salivary pH in the whole sample and among MW (r = 0.29 and r = 0.36, p salivary pH (R2) was 10.8% (p salivary pH quartiles (p = 0.005). These results suggest that salivary pH is a significant correlate of plasma adiponectin levels in women. With the increasing prevalence of type 2 diabetes and obesity, new technologies should be developed to more easily monitor health status, disease onset and progression. Salivary pH, a simple, inexpensive and non-invasive measure, could be a very promising avenue.

  16. Salivary pH as a marker of plasma adiponectin concentrations in Women

    Directory of Open Access Journals (Sweden)

    Tremblay Monique

    2012-02-01

    Full Text Available Abstract Background Plasma adiponectin is a significant correlate of the pro-inflammatory cardiometabolic risk profile associated with obesity and type 2 diabetes. Salivary pH is influenced by several cardiometabolic risk components such as inflammation, oxidation and numerous oral and systemic health modulators, including the menopausal status. This study aimed to assess the association between plasma adiponectin concentrations and salivary pH in women according to the menopausal status. Method Unstimulated saliva collection was performed in 151 Caucasian women of French-Canadian origin (53 premenopausal women (PMW and 98 menopausal women (MW. Student's t test, ANOVA and linear regression models were used to assess the association between plasma adiponectin concentrations and salivary pH. Results Plasma adiponectin levels increased as a function of salivary pH in the whole sample and among MW (r = 0.29 and r = 0.36, p 2 was 10.8% (p Conclusions These results suggest that salivary pH is a significant correlate of plasma adiponectin levels in women. With the increasing prevalence of type 2 diabetes and obesity, new technologies should be developed to more easily monitor health status, disease onset and progression. Salivary pH, a simple, inexpensive and non-invasive measure, could be a very promising avenue.

  17. Serial changes in plasma K concentration during storage of irradiation blood products

    International Nuclear Information System (INIS)

    Togashi, Kazue; Yamada, Keiko; Otake, Sachiko; Saito, Yukiko; Sugimura, Kazuhito; Takahashi, Hoyu

    1996-01-01

    Irradiation of blood products is highly effective in the prevention of transfusion-associated graft-versus-host disease (GVHD). In order to assess the safe storage period of irradiated blood products, serial changes in plasma K, red cell 2,3-diphosphoglycerate (2,3-DPG) and lactic acid concentrations of whole blood and M·A·P-added red cell concentrate (RC-M·A·P) during storage at 5degC were measured after irradiation with 137 Cs by IBL 437C (CIS bio international). Plasma K concentration did not change immediately after irradiation, but increased more rapidly and in a radiation dose-dependent manner in the irradiated products than nonirradiated products. The changes in red cell 2,3-DPG and lactic acid concentrations were not affected by irradiation but were rather dependent on the storage period after blood collection. Plasma K concentrations of whole blood and RC-M·A·P irradiated with 25 Gy increased at 5 and 3 days, respectively, to the K levels observed after the storage of nonirradiated products for 21 days. It is therefore recommended that whole blood be used within 5 days and RC-M·A·P within 3 days when stored after irradiation with 25 Gy. (author)

  18. Use of antibiotics is associated with lower enterolactone plasma concentration

    DEFF Research Database (Denmark)

    Bolvig, Anne Katrine; Kyrø, Cecilie; Nørskov, Natalja

    2016-01-01

    Scope High enterolactone levels may have health benefits in relation to risk of noncommunicable diseases. Enterolactone is produced by the colonic microbiota after intake of lignans and treatment with antimicrobials may result in altered enterolactone production. This study investigates the assoc......Scope High enterolactone levels may have health benefits in relation to risk of noncommunicable diseases. Enterolactone is produced by the colonic microbiota after intake of lignans and treatment with antimicrobials may result in altered enterolactone production. This study investigates...... the association between antibiotic use and enterolactone concentration. Methods and results Using LC–MS/MS, enterolactone concentrations were quantified in plasma samples from 2237 participants from the Diet, Cancer and Health cohort. The participants were healthy at enrollment, but were later diagnosed...... with cancer. At enrollment, participants had blood drawn and completed a food frequency questionnaire and lifestyle questionnaire. Antibiotic use was assessed as reimbursed antibiotic prescriptions up to 12 months before enrollment. Antibiotic use ≤3 months before enrollment was associated with a 41% (Δcrude...

  19. Plasma concentrations of alpha-melanocyte-stimulating hormone are elevated in patients on chronic haemodialysis.

    Science.gov (United States)

    Airaghi, L; Garofalo, L; Cutuli, M G; Delgado, R; Carlin, A; Demitri, M T; Badalamenti, S; Graziani, G; Lipton, J M; Catania, A

    2000-08-01

    Clinical and/or laboratory signs of systemic inflammation occur frequently in patients undergoing long-term haemodialysis. It is likely, therefore, that a compensatory release of endogenous anti-inflammatory molecules occurs to limit host reactions. The aim of the present research was to determine if the potent anti-inflammatory peptide alpha-melanocyte-stimulating hormone (alpha-MSH), a pro-opiomelanocortin derivative, is increased in plasma of haemodialysis patients. Because endotoxin and cytokines induce alpha-MSH in vivo and in vitro, we also measured plasma concentrations of endotoxin, interleukin-6 (IL-6), and tumour necrosis factor alpha (TNF-alpha), and the two circulating products of activated monocytes, nitric oxide (NO) and neopterin. Thirty-five chronic haemodialysis patients, 20 patients with chronic renal failure not yet on dialysis, and 35 normal controls were included in the study. In the haemodialysis group, blood samples were obtained before and at the end of a dialysis session. Plasma alpha-MSH was measured using a double antibody radioimmunoassay, and IL-6, TNF-alpha, and neopterin using specific enzyme-linked immunosorbent assays. Plasma nitrites were determined by a colorimetric method, and endotoxin with the quantitative chromogenic LAL (limulus amoebocyte lysate) method. Mean plasma alpha-MSH was higher in haemodialysis patients than in control subjects, with the peptide concentrations being particularly elevated in dialysed patients with detectable endotoxin. High alpha-MSH concentrations were observed in the pre-dialysis samples, with no substantial change at the end of the dialysis session. Plasma concentrations of IL-6, TNF-alpha, neopterin, and NO were generally elevated in chronic haemodialysis patients and there was a negative correlation between circulating alpha-MSH and IL-6. In patients with renal failure not yet on dialysis, mean plasma alpha-MSH was similar to that of normal subjects. alpha-MSH is increased in the circulation of

  20. Association between plasma homocysteine concentrations and extracranial carotid stenosis

    International Nuclear Information System (INIS)

    Mousavi, Seyed Ali; Ghasemi, M.; Hoseini, T.

    2006-01-01

    Increasing epidemiologic data support a relationship between elevated plasma total homocysteine levels and an increased risk for vascular disease. Higher plasma total homocysteine (tHcy) levels have been associated with extracranial carotid atherosclerosis and cerebral infarction in whites. However, data regarding such associations are limited for Asians. This study examined the association between tHcy level and carotid stenosis in Iranian subjects. In this retrospective study, the subjects were 158 patients with ischemic stroke, including 105 with a normal tHcy level and 53 with a high tHcy level. We investigated the extracranial carotid arteries by ultrasonography and measured serum tHcy by ELISA method in these two groups. We found no meaningful association between a high tHcy level and carotid stenosis. The lack of any meaningful difference in carotid stenosis between patients with normal and elevated tHcy levels is probably due to the low frequency of extracranial diseases in the Asian population and to the nature of homocysteine atherosclerosis. (author)

  1. Measurement of radon activity concentration in buildings

    International Nuclear Information System (INIS)

    Godet, J.L.; Perrin, M.L.; Pineau, C.; Dechaux, E.

    2010-01-01

    Radon exposure, along with medical-related exposure, is the leading source of exposure to ionising radiation for the French population. Measurement campaigns are done in the action plan, drawn up by the French nuclear safety authority (ASN), in cooperation with the French directorate for housing, town planning and countryside (DHUP), the French radiation protection and nuclear safety institute (IRSN), the French health monitoring institute (InVS) and the French scientific and technical centre for construction (CSTB). The review of 2005-2008 measurement campaign shows that of the 7356 buildings screened, 84.8% had activity concentration levels below the 400 Bq/m 3 action level. For the other buildings (15.2%), action will be required to reduce human exposure to radon, possibly including building renovation/redevelopment work. In the 1999-2002 measurement campaign,12% of the 13,000 buildings screened had a radon activity concentration level higher than 400 Bq/m 3 . In addition, the ASN and the French general directorate of labour (DGT) are continuing to work on drawing up regulations for occupational risk management. The second national health and environment plan (PNSE 2) was published on 26 June 2009. It follows on from the actions initiated in PNSE 1, a document provided for under the Public Health Act dated 9 August 2004 and under the French 'Grenelle' environmental agreements. On the basis of guidelines laid out in PNSE 2, a radon action plan for 2009-2012 will be drawn up, enabling some of the actions to be continued, particularly in the fields of new building projects and dwellings. (author)

  2. Plasma concentrations of the cyclic nucleotides, adenosine 3',5'-monophosphate and guanosine 3'.5'-monophosphate, in healthy adults treated with theophylline

    DEFF Research Database (Denmark)

    Fenger, M; Eriksen, P B; Andersen, O

    1982-01-01

    Plasma concentrations of cyclic adenosine monophosphate and cyclic guanosine monophosphate were measured in 10 health adults before, during and after periods of theophylline administration. Cyclic adenosine monophosphate concentrations did not change significantly, but cyclic guanosine monophosph...

  3. Plasma concentrations, behavioural and physiological effects following intravenous and intramuscular detomidine in horses.

    Science.gov (United States)

    Mama, K R; Grimsrud, K; Snell, T; Stanley, S

    2009-11-01

    Detomidine hydrochloride is used to provide sedation, muscle relaxation and analgesia in horses, but a lack of information pertaining to plasma concentration has limited the ability to correlate drug concentration with effect. To build on previous information and assess detomidine for i.v. and i.m. use in horses by simultaneously assessing plasma drug concentrations, physiological parameters and behavioural characteristics. Systemic effects would be seen following i.m. and i.v. detomidine administration and these effects would be positively correlated with plasma drug concentrations. Behavioural (e.g. head position) and physiological (e.g. heart rate) responses were recorded at fixed time points from 4 min to 24 h after i.m. or i.v. detomidine (30 microg/kg bwt) administration to 8 horses. Route of administration was assigned using a balanced crossover design. Blood was sampled at predetermined time points from 0.5 min to 48 h post administration for subsequent detomidine concentration measurements using liquid chromatography-mass spectrometry. Data were summarised as mean +/- s.d. for subsequent analysis of variance for repeated measures. Plasma detomidine concentration peaked earlier (1.5 min vs. 1.5 h) and was significantly higher (105.4 +/- 71.6 ng/ml vs. 6.9 +/- 1.4 ng/ml) after i.v. vs. i.m. administration. Physiological and behavioural changes were of a greater magnitude and observed at earlier time points for i.v. vs. i.m. groups. For example, head position decreased from an average of 116 cm in both groups to a low value 35 +/- 23 cm from the ground 10 min following i.v. detomidine and to 64 +/- 24 cm 60 min after i.m. detomidine. Changes in heart rate followed a similar pattern; low value of 17 beats/min 10 min after i.v. administration and 29 beats/min 30 min after i.m. administration. Plasma drug concentration and measured effects were correlated positively and varied with route of administration following a single dose of detomidine. Results support a

  4. EXTENDED STORAGE OF BUFFY-COAT PLATELET CONCENTRATES IN PLASMA OR A PLATELET ADDITIVE SOLUTION

    Science.gov (United States)

    Slichter, Sherrill J.; Bolgiano, Doug; Corson, Jill; Jones, Mary Kay; Christoffel, Todd; Bailey, S. Lawrence; Pellham, Esther

    2014-01-01

    Background Platelet concentrates prepared from whole blood in the U.S. are made using the platelet-rich-plasma (PRP) method. The platelet concentrates must be made within 8 hours of blood collection and stored for only 5 days. In Europe and Canada, platelet concentrates are made using the buffy-coat (BC) method from whole blood held overnight at 22°C and storage times may be up to 7 days. Our studies were designed to determine how long BC platelets can be stored in plasma or Plasmalyte while meeting the FDA’s post-storage viability criteria. Study Design, Materials, And Methods Normal subjects donated whole blood that was stored at 22°C for 22 ± 2 hours prior to preparation of BC platelets. Platelets were stored for 5 to 8 days in either plasma or Plasmalyte concentrations of 65% or 80%. Radiolabeled autologous stored versus fresh platelet recoveries and survivals were assessed as well as post-storage in vitro assays. Results BC platelets stored in either plasma or 65% Plasmalyte met FDA post-storage platelet recovery criteria for 7 days but survivals for only 6 days, while storage in 80% Plasmalyte gave very poor results. Both stored platelet recoveries and survivals correlated with the same donor’s fresh results, but the correlation was much stronger between recoveries than survivals. In vitro measures of extent of shape change, morphology score, and pH best predicted post-storage platelet recoveries, while annexin V binding best predicted platelet survivals. Conclusion BC platelets stored in either plasma or 65% Plasmalyte meet FDA’s post-storage viability criteria for 6 days. PMID:24673482

  5. Device for measuring the tritium concentration in a measuring gas

    International Nuclear Information System (INIS)

    Koran, P.

    1987-01-01

    The measuring gas is brought into contact via a measuring gas path with a diaphragm permeable to water, which separates the measuring gas path from a counter gas path leading to a proportional detector. The measuring gas path and the counter gas path are in counterflow in the area of diaphragm. The preferably hose diaphragm consists of a well-known ion exchange material, which can be used for gas drying purposes, which is permeable to water and tritium compounds similar to water, but is impermeable to other gases and liquids contained in air, particularly rare gases. In this way, the tritium concentration can be measured with great rare gas suppression. (orig./HP) [de

  6. Plasma Aluminum Concentrations in Pediatric Patients Receiving Long-Term Parenteral Nutrition.

    Science.gov (United States)

    Courtney-Martin, Glenda; Kosar, Christina; Campbell, Alison; Avitzur, Yaron; Wales, Paul W; Steinberg, Karen; Harrison, Debra; Chambers, Kathryn

    2015-07-01

    Patients receiving long-term parenteral nutrition (PN) are at increased risk of aluminium (Al) toxicity because of bypass of the gastrointestinal tract during PN infusion. Complications of Al toxicity include metabolic bone disease (MBD), Al-associated encephalopathy in adults, and impaired neurological development in preterm infants. Unlike the United States, there are no regulations regarding Al content of large- and small-volume parenterals in Canada. We, therefore, aimed to present our data on plasma Al concentration and Al intake from our cohort of pediatric patients receiving long-term PN. Plasma Al concentration was retrospectively gathered from the patient charts of all 27 patients with intestinal failure (IF) receiving long-term PN at The Hospital for Sick Children, Toronto, Canada, and compared with age- and sex-matched controls recruited for comparison. In addition, Al concentration was measured in PN samples collected from 10 randomly selected patients with IF and used to determine their Al intake. The plasma Al concentration of patients with IF receiving long-term PN was significantly higher than that of control participants (1195 ± 710 vs 142 ± 63 nmol/L; P Parenteral and Enteral Nutrition.

  7. Effect of temperature on the concentration of plasma gonadotropine and spermatogenesis of the goldfish Carassius auratus

    Energy Technology Data Exchange (ETDEWEB)

    Gillet, C.; Billard, R.; Breton, B.

    1977-01-01

    Concentrations of immunoreactive plasma gonadotropin (c-GtH) were measured for goldfish kept at conditions of temperature held constant or increasing between 10 and 30/sup 0/C, between February and July. At temperatures of 17/sup 0/C or above the levels of plasma c-GtH were significantly (P < 0.005) higher during April and May than at 10/sup 0/C. In April the pituitary concentration of c-GtH was maximum for fish held at 17/sup 0/C or above and the minimum for fish held below 17/sup 0/C, but in June the situation was reversed. A study of the gonads showed that spermatogenesis is faster at 17--24/sup 0/C than at 10/sup 0/C, but at 30/sup 0/C spermatogenic activity was inhibited.

  8. Measurement of plasma conductivity using faraday rotation of submillimeter waves

    International Nuclear Information System (INIS)

    Kuzmenko, P.J.; Self, S.A.

    1983-01-01

    This paper examines the application of Faraday rotation to the measurement of electron combustion MHD plasmas. Details on the design of a working system are given, including the selection of operating wavelength. A theoretical comparison between the Faraday rotation technique and two-path interferometry shows Faraday rotation in its simplest form to be somewhat less sensitive to changes in electron concentration. This deficit can be balanced against greater immunity to vibration and thermal drift. Improved techniques of measuring the rotation angle promise greater sensitivity. A preliminary experiment has verified the technique

  9. Childhood obesity treatment; Effects on BMI SDS, body composition, and fasting plasma lipid concentrations.

    Directory of Open Access Journals (Sweden)

    Tenna Ruest Haarmark Nielsen

    Full Text Available The body mass index (BMI standard deviation score (SDS may not adequately reflect changes in fat mass during childhood obesity treatment. This study aimed to investigate associations between BMI SDS, body composition, and fasting plasma lipid concentrations at baseline and during childhood obesity treatment.876 children and adolescents (498 girls with overweight/obesity, median age 11.2 years (range 1.6-21.7, and median BMI SDS 2.8 (range 1.3-5.7 were enrolled in a multidisciplinary outpatient treatment program and followed for a median of 1.8 years (range 0.4-7.4. Height and weight, body composition measured by dual-energy X-ray absorptiometry, and fasting plasma lipid concentrations were assessed at baseline and at follow-up. Lipid concentrations (total cholesterol (TC, low-density lipoprotein (LDL, high-density lipoprotein (HDL, non-HDL, and triglycerides (TG were available in 469 individuals (264 girls. Linear regressions were performed to investigate the associations between BMI SDS, body composition indices, and lipid concentrations.At baseline, BMI SDS was negatively associated with concentrations of HDL (p = 6.7*10-4 and positively with TG (p = 9.7*10-6. Reductions in BMI SDS were associated with reductions in total body fat percentage (p<2*10-16 and percent truncal body fat (p<2*10-16. Furthermore, reductions in BMI SDS were associated with improvements in concentrations of TC, LDL, HDL, non-HDL, LDL/HDL-ratio, and TG (all p <0.0001. Changes in body fat percentage seemed to mediate the changes in plasma concentrations of TC, LDL, and non-HDL, but could not alone explain the changes in HDL, LDL/HDL-ratio or TG. Among 81 individuals with available lipid concentrations, who increased their BMI SDS, 61% improved their body composition, and 80% improved their lipid concentrations.Reductions in the degree of obesity during multidisciplinary childhood obesity treatment are accompanied by improvements in body composition and fasting plasma

  10. Measurement of Debye length in laser-produced plasma.

    Science.gov (United States)

    Ehler, W.

    1973-01-01

    The Debye length of an expanded plasma created by placing an evacuated chamber with an entrance slit in the path of a freely expanding laser produced plasma was measured, using the slab geometry. An independent measurement of electron density together with the observed value for the Debye length also provided a means for evaluating the plasma electron temperature. This temperature has applications in ascertaining plasma conductivity and magnetic field necessary for confinement of the laser produced plasma. Also, the temperature obtained would be useful in analyzing electron-ion recombination rates in the expanded plasma and the dynamics of the cooling process of the plasma expansion.

  11. Medium-chain triglycerides in infant formulas and their relation to plasma ketone body concentrations.

    Science.gov (United States)

    Wu, P Y; Edmond, J; Auestad, N; Rambathla, S; Benson, J; Picone, T

    1986-04-01

    A mild ketosis is known to prevail in the mother, fetus, and newborn infant during the 3rd trimester and in the early neonatal period. It has been shown that during an equivalent period in the rat ketone bodies are readily oxidized and serve as key substrates for lipogenesis in brain. Since medium-chain triglycerides are known to be ketogenic, preterm infants may benefit from dietary medium-chain triglycerides beyond the point of enhanced fat absorption. Our objective was to determine the ketogenic response in preterm infants (gestational age: 33 +/- 0.8 wk) fed three different isocaloric formulas by measuring the concentrations of 3-hydroxybutyrate and acetoacetate in the plasma of these infants. At the time of entrance to the study the infants were receiving 110 kcal/kg/24 h. Study I (11 infants): the infants were fed sequentially in the order; PM 60/40 (PM), Special Care Formula (SCF), and Similac 20 (SIM). In SCF greater than 50% of the fat consists of medium-chain length fatty acids while PM and SIM contain about 25%. The concentration of 3-hydroxybutyrate in plasma was significantly higher when infants were fed SCF than PM and SIM [0.14 +/- 0.03, 0.06 +/- 0.01, and 0.05 +/- 0.01 mM, respectively (p less than 0.01)]. Study II (12 infants); the infants were fed SCF, then SIM, or the reverse. The concentration of acetoacetate in plasma was 0.05 +/- 0.01 and 0.03 +/- 0.01 mM when infants were fed SCF and SIM, respectively (0.1 greater than p greater than 0.05). The concentrations of 3-hydroxybutyrate in plasma were similar to those measured in study I for the respective formulas.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Relationship between physical activity and plasma fibrinogen concentrations in adults without chronic diseases.

    Directory of Open Access Journals (Sweden)

    Manuel A Gomez-Marcos

    Full Text Available To analyze the relationship between regular physical activity, as assessed by accelerometer and 7-day physical activity recall (PAR, and plasma fibrinogen concentrations.A cross-sectional study in a previously established cohort of healthy subjects was performed. This study analyzed 1284 subjects who were included in the EVIDENT study (mean age 55.0±13.6 years; 60.90% women. Fibrinogen concentrations were measured in blood plasma. Physical activity was assessed with a 7-day PAR (metabolic equivalents (METs/hour/week and GT3X ActiGraph accelerometer (counts/minute for 7 days.Physical exercise, which was evaluated with both an accelerometer (Median: 237.28 counts/minute and 7-day PAR (Median: 8 METs/hour/week. Physical activity was negatively correlated with plasma fibrinogen concentrations, which was evaluated by counts/min (r = -0.100; p<0.001 and METs/hour/week (r = -0.162; p<0.001. In a multiple linear regression analysis, fibrinogen concentrations of the subjects who performed more physical activity (third tertile of count/minute and METs/hour/week respect to subjects who performed less (first tertile, maintained statistical significance after adjustments for age and others confounders (β = -0.03; p = 0.046 and β = -0.06; p<0.001, respectively.Physical activity, as assessed by accelerometer and 7-day PAR, was negatively associated with plasma fibrinogen concentrations. This relation is maintained in subjects who performed more exercise even after adjusting for age and other confounders.

  13. Electron density measurements on the plasma focus

    International Nuclear Information System (INIS)

    Rueckle, B.

    1976-01-01

    The paper presents a determination of the maximum electron density in a plasma focus, produced with the NESSI experimental setup, by the method of laser beam deflection. For each discharge a time-resolved measurement was performed at four different places. Neutron efficiency as well as the time of the initial X-ray emission was registrated. The principle and the economic aspects of the beam deflection method are presented in detail. The experimental findings and the resulting knowledge of the neutron efficiency are discussed. (GG) [de

  14. Surface resistivity measurement of plasma treated polymers

    International Nuclear Information System (INIS)

    Simon, D.; Pigram, P.J.; Liesegang, J.

    2000-01-01

    Full text: Resistivity of insulators is an important property of materials used within the integrated circuit and packaging industries. The measurement of electrical resistivity of insulator materials in the surface region in this work is interpreted through observations of surface charge decay. A self-field driven and diffusion charge transport theory is used to model the process and resistivity values obtained computationally. Data for the charge decay of surface charged samples are collected by suspending them inside a coaxial cylinder connected to an electrometer. Samples used have been low density polyethylene LDPE sheet, both pristine and surface treated. Some samples have been treated by air plasma at low vacuum pressures for different periods of time; others have been washed in ethyl acetate and then plasma treated before the resistivity measurement. The sets of resistivity measurements form the various treatments are compared below. X-ray photoelectron spectroscopy (XPS) has also been used to investigate and account for the observed variations in surface resistivity

  15. The influence of a cooked meat meal on creatinine plasma concentration and creatinine clearance.

    OpenAIRE

    Mayersohn, M; Conrad, K A; Achari, R

    1983-01-01

    1 The influence of a meal containing cooked meat (225 g) on creatinine plasma concentration, creatinine urinary excretion and creatinine clearance was determined in six healthy male subjects. 2 The meat meal produced an average 52% increase in creatinine plasma concentration within 1.5 to 3.5 h after ingestion. The 24 h area under the creatinine plasma concentration-time curve increased by about 19%. Urinary creatinine excretion during 24 h increased by an average of 13%. Creatinine clearance...

  16. Maternal plasma concentrations of beta-lipotrophin, beta-endorphin and gamma-lipotrophin throughout pregnancy.

    Science.gov (United States)

    Browning, A J; Butt, W R; Lynch, S S; Shakespear, R A

    1983-12-01

    Plasma beta-LPH, beta-EP and gamma-LPH concentrations were measured by radioimmunoassay in 10 pregnant women from 12 weeks gestation until term and in nine women in the early follicular phase of the cycle. There was a progressive and significant rise in the concentration of all three peptides throughout pregnancy and by 32 weeks the concentrations of beta-LPH and beta-EP were greater than the corresponding concentrations in the follicular phase: gamma-LPH was greater than in the follicular phase by the end of pregnancy in those women who were delivered after 40 weeks. The ratio of beta-LPH to gamma-LPH did not change significantly throughout pregnancy, but there was a progressive fall in the beta-LPH/beta-EP ratio. The possible presence of a 'big LPH' to explain this finding is discussed.

  17. Frequency of soup intake and amount of dietary fiber intake are inversely associated with plasma leptin concentrations in Japanese adults.

    Science.gov (United States)

    Kuroda, Motonaka; Ohta, Masanori; Okufuji, Tatsuya; Takigami, Chieko; Eguchi, Masafumi; Hayabuchi, Hitomi; Ikeda, Masaharu

    2010-06-01

    Previous studies have shown that the intake of soup negatively correlates with the body mass index (BMI), suggesting that soup intake reduces the risk of obesity. In this study, to clarify the association of the intake of soup and various nutrients with plasma leptin concentration, a cross-sectional study on 504 Japanese adults aged 20-76 years (103 men and 401 women) was performed. The intake of soup and various nutrients was investigated by food frequency questionnaires. Plasma leptin concentration was measured in fasting blood by radioimmunoassay. The correlation was analyzed by multiple regression analysis. The average frequency of soup intake was 7.6 times/week. The average plasma leptin concentration was 7.76 ng/ml. After adjusting the confounding factors, the frequency of soup intake has a significant inverse association with plasma leptin concentration. Among the macronutrients, only dietary fiber intake negatively correlated with plasma leptin concentration after the adjustment for potential confounding factors. These results suggest that the intakes of soup and dietary fiber were negatively correlated with plasma leptin concentration in Japanese adults. Copyright 2010 Elsevier Ltd. All rights reserved.

  18. Treatment with clozapine and its effect on plasma homovanillic acid and norepinephrine concentrations in schizophrenia.

    Science.gov (United States)

    Davidson, M; Kahn, R S; Stern, R G; Hirschowitz, J; Apter, S; Knott, P; Davis, K L

    1993-02-01

    Measurement of plasma concentrations of the dopamine metabolite, homovanillic acid (pHVA), is an indirect tool to assess changes in dopamine turnover. Levels of pHVA have been reported to decrease during treatment with conventional antidopaminergic, neuroleptics, with the decrement correlating with symptomatic improvement in schizophrenic symptoms. Clozapine, an atypical neuroleptic, is the only drug proved to be effective in treatment-refractory patients. However, the mechanism mediating this unique efficacy has not been fully elucidated. This study examined the effect of clozapine on pHVA concentrations in schizophrenic patients. Since clozapine potently binds to alpha 2-adrenergic receptors, plasma norepinephrine (pNE) concentrations were also measured. Twenty-eight treatment-refractory schizophrenic patients (24 men, 4 women) were treated with clozapine (up to 600 mg/day) for 5 weeks, after a minimum 1-week drug-free period. Symptomatology and pHVA and pNE concentrations were measured at the last drug-free day and weekly for 5 weeks. Fourteen patients responded to clozapine treatment, while an equal number did not. Mean pHVA concentrations did not significantly change during treatment with clozapine. Although clozapine tended to lower pHVA concentrations in treatment responders, the effect was small and not significant. Clozapine treatment significantly raised pNE concentrations, but this did not differentiate responders from nonresponders to clozapine. These findings suggest that clozapine's effect on DA turnover is small and that clozapine may be effective in treatment-refractory schizophrenia by mechanisms other than, or in addition to, dopamine receptor blockade. However, since about one-third of NE is metabolized into HVA, the clozapine-induced increase in pNE may have overshadowed a possible lowering effect of clozapine on pHVA.

  19. Plasma B-type natriuretic peptide concentration for diagnosis of acute heart failure with renal insufficiency

    Directory of Open Access Journals (Sweden)

    Naila Atik Khan

    2016-07-01

    Full Text Available Background : Plasma B-type natriuretic peptide (BNP is the diagnostic tool for acute heart failure (AHF.This natriu­retic peptide level depends on renal function, through renal metabolism and excretion. Therefore we examined the effect ofrenal impairment on plasma BNP level during diagnosis of AHF.Objective: The objective of the study was to assess the effect of renal dysfunction on plasma BNP level and to determine appropriate cutoff value of plasma BNP to diagnose the patients of AHF with renal insufficiency.Methods: This cross sectional analytical study was conducted in the Depart­ment of Biochemistry Bangabandhu Sheikh Mujib Medical University (BSMMU. The study was done among 90 AHF patients selected from cardiology emergency department during the period of July 2012 to June 2013. After enrollment plasma BNP concentration was measured and eGFR was estimated from serum creatinine by the four parameter Modifica­tion of Diet and Renal Disease (MORD equation and then grouped into two groups on the basis of empirical cut off value of eGFR 60 ml/min/1.73 m2Results: In this study a significant negative correlation was found between plasma BNP evel and eGFR (P<0.001 , with higher BNP levels observed as eGFR declined. The optimal BNP cutoff value for diagno­sis of AHF patients with renal insufficiency was 824 pg/ml. At this cutoff level AHF with renal insufficiency could be diagnosed with sensitivity and specificity of 84% and 71 %, respectively.Conclusions: By adjusting the cutoff value, plasma BNP can be used to diagnose AHF with renal insufficiency with an acceptable sensitivity and specificity.

  20. Plasma ATP concentration and venous oxygen content in the forearm during dynamic handgrip exercise

    Directory of Open Access Journals (Sweden)

    Askew Christopher D

    2009-12-01

    Full Text Available Abstract Background It has been proposed that adenosine triphosphate (ATP released from red blood cells (RBCs may contribute to the tight coupling between blood flow and oxygen demand in contracting skeletal muscle. To determine whether ATP may contribute to the vasodilatory response to exercise in the forearm, we measured arterialised and venous plasma ATP concentration and venous oxygen content in 10 healthy young males at rest, and at 30 and 180 seconds during dynamic handgrip exercise at 45% of maximum voluntary contraction (MVC. Results Venous plasma ATP concentration was elevated above rest after 30 seconds of exercise (P Conclusions Collectively these results indicate that ATP in the plasma originated from the muscle microcirculation, and are consistent with the notion that deoxygenation of the blood perfusing the muscle acts as a stimulus for ATP release. That ATP concentration was elevated just 30 seconds after the onset of exercise also suggests that ATP may be a contributing factor to the blood flow response in the transition from rest to steady state exercise.

  1. High plasma concentrations of asymmetric dimethylarginine inhibit ischemic cardioprotection in hypercholesterolemic rats

    International Nuclear Information System (INIS)

    Landim, M.B.P.; Dourado, P.M.M.; Casella-Filho, A.; Chagas, A.C.P.; Luz, P.L. da

    2013-01-01

    A low concentration of nitric oxide associated with a high concentration of asymmetric dimethylarginine (ADMA) can explain the lack of ischemic cardioprotection observed in the presence of hypercholesterolemia. The objective of the present study was to evaluate the effect of hypercholesterolemia on ischemic pre- and postconditioning and its correlation with plasma concentrations of ADMA. Male Wistar rats (6-8 weeks old) fed a 2% cholesterol diet (n = 21) for 8 weeks were compared to controls (n = 25) and were subjected to experimental myocardial infarction and reperfusion, with ischemic pre- and postconditioning. Total cholesterol and ADMA were measured in plasma before the experimental infarct and the infarct area was quantified. Weight, total cholesterol and plasma ADMA (means ± SE; 1.20 ± 0.06, 1.27 ± 0.08 and 1.20 ± 0.08 vs 0.97 ± 0.04, 0.93 ± 0.05 and 0.97 ± 0.04 µM) were higher in animals on the hypercholesterolemic diet than in controls, respectively. Cardioprotection did not reduce infarct size in the hypercholesterolemic animals (pre: 13.55% and post: 8% compared to 7.95% observed in the group subjected only to ischemia and reperfusion), whereas infarct size was reduced in the animals on a normocholesterolemic diet (pre: 8.25% and post: 6.10% compared to 12.31%). Hypercholesterolemia elevated ADMA and eliminated the cardioprotective effects of ischemic pre- and postconditioning in rats

  2. High plasma concentrations of asymmetric dimethylarginine inhibit ischemic cardioprotection in hypercholesterolemic rats

    Energy Technology Data Exchange (ETDEWEB)

    Landim, M.B.P.; Dourado, P.M.M.; Casella-Filho, A.; Chagas, A.C.P.; Luz, P.L. da [Unidade de Aterosclerose, Instituto do Coração, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil)

    2013-05-10

    A low concentration of nitric oxide associated with a high concentration of asymmetric dimethylarginine (ADMA) can explain the lack of ischemic cardioprotection observed in the presence of hypercholesterolemia. The objective of the present study was to evaluate the effect of hypercholesterolemia on ischemic pre- and postconditioning and its correlation with plasma concentrations of ADMA. Male Wistar rats (6-8 weeks old) fed a 2% cholesterol diet (n = 21) for 8 weeks were compared to controls (n = 25) and were subjected to experimental myocardial infarction and reperfusion, with ischemic pre- and postconditioning. Total cholesterol and ADMA were measured in plasma before the experimental infarct and the infarct area was quantified. Weight, total cholesterol and plasma ADMA (means ± SE; 1.20 ± 0.06, 1.27 ± 0.08 and 1.20 ± 0.08 vs 0.97 ± 0.04, 0.93 ± 0.05 and 0.97 ± 0.04 µM) were higher in animals on the hypercholesterolemic diet than in controls, respectively. Cardioprotection did not reduce infarct size in the hypercholesterolemic animals (pre: 13.55% and post: 8% compared to 7.95% observed in the group subjected only to ischemia and reperfusion), whereas infarct size was reduced in the animals on a normocholesterolemic diet (pre: 8.25% and post: 6.10% compared to 12.31%). Hypercholesterolemia elevated ADMA and eliminated the cardioprotective effects of ischemic pre- and postconditioning in rats.

  3. Plasma concentrations of osteoprotegerin during normo- and hyperglycaemic clamping

    DEFF Research Database (Denmark)

    Knudsen, S T; Jeppesen, Peter; Poulsen, P L

    2007-01-01

    OBJECTIVE: Plasma levels of osteoprotegerin (OPG) are elevated in subjects with diabetes as well as in non-diabetic subjects with cardiovascular disease. In previous studies a positive correlation was found between plasma levels of OPG and markers of glycaemic control in diabetic subjects. The aim...

  4. Effects of total gastrectomy on plasma silicon and amino acid concentrations in men.

    Science.gov (United States)

    Tatara, Marcin R; Krupski, Witold; Szpetnar, Maria; Dąbrowski, Andrzej; Bury, Paweł; Szabelska, Anna; Charuta, Anna; Boguszewska-Czubara, Anna; Maciejewski, Ryszard; Wallner, Grzegorz

    2015-12-01

    The aim of the study was to determine one-year effects of total gastrectomy on plasma silicon and free amino acid concentrations in patients and evaluate changes of volumetric bone mineral density (vBMD) in lumbar spine. Eight patients were enrolled to the control (CTR) group. Six patients subjected to total gastrectomy (GX group) were included to the experimental group. vBMD in trabecular and cortical bone was measured in lumbar vertebrae at baseline (before surgery) and one year later using quantitative computed tomography. Plasma concentrations of silicon and free amino acids were determined at baseline and one year later using photometric method and ion-exchange chromatography. Body weights within CTR and GX groups were not different after one-year follow-up when compared to the baseline values (P > 0.05). An average annual decrease of vBMD in the trabecular bone in the gastrectomized patients reached 15.0% in lumbar spine and was significantly different in comparison to the percentage changes observed in CTR group (P = 0.02). One-year percentage change of vBMD in the cortical bone in L1 and L2 has shown significantly decreased values by 10.5 and 9.1% in the GX group when compared to the percentage change observed in the controls (P silicon was significantly lowered by 26.7% one year after the total gastrectomy when compared to the baseline value (P = 0.009). Total gastrectomy in patients has induced severe osteoporotic changes in lumbar spine within one-year period. The observed osteoporotic changes were associated with decreased plasma concentration of silicon indicating importance of exocrine and endocrine functions of stomach for silicon homeostasis maintenance. Gastrectomy-induced bone loss was not related to decreased amino acid concentration in plasma obtained from overnight fasted patients. © 2015 by the Society for Experimental Biology and Medicine.

  5. DAQ system for low density plasma parameters measurement

    International Nuclear Information System (INIS)

    Joshi, Rashmi S.; Gupta, Suryakant B.

    2015-01-01

    In various cases where low density plasmas (number density ranges from 1E4 to 1E6 cm -3 ) exist for example, basic plasma studies or LEO space environment measurement of plasma parameters becomes very critical. Conventional tip (cylindrical) Langmuir probes often result into unstable measurements in such lower density plasma. Due to larger surface area, a spherical Langmuir probe is used to measure such lower plasma densities. Applying a sweep voltage signal to the probe and measuring current values corresponding to these voltages gives V-I characteristics of plasma which can be plotted on a digital storage oscilloscope. This plot is analyzed for calculating various plasma parameters. The aim of this paper is to measure plasma parameters using a spherical Langmuir probe and indigenously developed DAQ system. DAQ system consists of Keithley source-meter and a host system connected by a GPIB interface. An online plasma parameter diagnostic system is developed for measuring plasma properties for non-thermal plasma in vacuum. An algorithm is developed using LabVIEW platform. V-I characteristics of plasma are plotted with respect to different filament current values and different locations of Langmuir probe with reference to plasma source. V-I characteristics is also plotted for forward and reverse voltage sweep generated programmatically from the source meter. (author)

  6. Plasma lactate concentration as a predictor of gastric necrosis and survival among dogs with gastric dilatation-volvulus: 102 cases (1995-1998).

    Science.gov (United States)

    de Papp, E; Drobatz, K J; Hughes, D

    1999-07-01

    To determine relationships between plasma lactate concentration and gastric necrosis and between plasma lactate concentration and outcome for dogs with gastric dilatation-volvulus. Retrospective study. 102 dogs. Information on signalment, history, plasma lactate concentration, medical and surgical treatment, cost of hospitalization, and outcome was retrieved from medical records. 69 of 70 (99%) dogs with plasma lactate concentration dogs with plasma lactate concentration > 6.0 mmol/L (1 dog euthanatized for economic reasons was not included). Gastric necrosis was identified in 38 (37%) dogs. Median plasma lactate concentration in dogs with gastric necrosis (6.6 mmol/L) was significantly higher than concentration in dogs without gastric necrosis (3.3 mmol/L). Specificity and sensitivity of using plasma lactate concentration (with a cutoff of 6.0 mmol/L) to predict which dogs had gastric necrosis were 88 and 61%, respectively. Sixty-two of 63 (98%) dogs without gastric necrosis survived, compared with 25 of 38 (66%) dogs with gastric necrosis. Preoperative plasma lactate concentration was a good predictor of gastric necrosis and outcome for dogs with GDV. Preoperative measurement of plasma lactate concentration may assist in determining prognosis of dogs with GDV.

  7. Seminal Plasma HIV-1 RNA Concentration Is Strongly Associated with Altered Levels of Seminal Plasma Interferon-γ, Interleukin-17, and Interleukin-5

    Science.gov (United States)

    Hoffman, Jennifer C.; Anton, Peter A.; Baldwin, Gayle Cocita; Elliott, Julie; Anisman-Posner, Deborah; Tanner, Karen; Grogan, Tristan; Elashoff, David; Sugar, Catherine; Yang, Otto O.

    2014-01-01

    Abstract Seminal plasma HIV-1 RNA level is an important determinant of the risk of HIV-1 sexual transmission. We investigated potential associations between seminal plasma cytokine levels and viral concentration in the seminal plasma of HIV-1-infected men. This was a prospective, observational study of paired blood and semen samples from 18 HIV-1 chronically infected men off antiretroviral therapy. HIV-1 RNA levels and cytokine levels in seminal plasma and blood plasma were measured and analyzed using simple linear regressions to screen for associations between cytokines and seminal plasma HIV-1 levels. Forward stepwise regression was performed to construct the final multivariate model. The median HIV-1 RNA concentrations were 4.42 log10 copies/ml (IQR 2.98, 4.70) and 2.96 log10 copies/ml (IQR 2, 4.18) in blood and seminal plasma, respectively. In stepwise multivariate linear regression analysis, blood HIV-1 RNA level (pplasma HIV-1 RNA level. After controlling for blood HIV-1 RNA level, seminal plasma HIV-1 RNA level was positively associated with interferon (IFN)-γ (p=0.03) and interleukin (IL)-17 (p=0.03) and negatively associated with IL-5 (p=0.0007) in seminal plasma. In addition to blood HIV-1 RNA level, cytokine profiles in the male genital tract are associated with HIV-1 RNA levels in semen. The Th1 and Th17 cytokines IFN-γ and IL-17 are associated with increased seminal plasma HIV-1 RNA, while the Th2 cytokine IL-5 is associated with decreased seminal plasma HIV-1 RNA. These results support the importance of genital tract immunomodulation in HIV-1 transmission. PMID:25209674

  8. Bone marrow concentrate and platelet-rich plasma differ in cell distribution and interleukin 1 receptor antagonist protein concentration.

    Science.gov (United States)

    Cassano, Jennifer M; Kennedy, John G; Ross, Keir A; Fraser, Ethan J; Goodale, Margaret B; Fortier, Lisa A

    2018-01-01

    Bone marrow concentrate (BMC) and platelet-rich plasma (PRP) are used extensively in regenerative medicine. The aim of this study was to determine differences in the cellular composition and cytokine concentrations of BMC and PRP and to compare two commercial BMC systems in the same patient cohort. Patients (29) undergoing orthopaedic surgery were enrolled. Bone marrow aspirate (BMA) was processed to generate BMC from two commercial systems (BMC-A and BMC-B). Blood was obtained to make PRP utilizing the same system as BMC-A. Bone marrow-derived samples were cultured to measure colony-forming units, and flow cytometry was performed to assess mesenchymal stem cell (MSC) markers. Cellular concentrations were assessed for all samples. Catabolic cytokines and growth factors important for cartilage repair were measured using multiplex ELISA. Colony-forming units were increased in both BMCs compared to BMA (p BMC-A and PRP, but there were differences in leucocyte concentrations. TGF-β1 and PDGF were not different between BMC-A and PRP. IL-1ra concentrations were greater (p = 0.0018) in BMC-A samples (13,432 pg/mL) than in PRP (588 pg/mL). The IL-1ra/IL-1β ratio in all BMC samples was above the value reported to inhibit IL-1β. The bioactive factors examined in this study have differing clinical effects on musculoskeletal tissue. Differences in the cellular and cytokine composition between PRP and BMC and between BMC systems should be taken into consideration by the clinician when choosing a biologic for therapeutic application. Clinical, Level II.

  9. Uranium concentrations in fossils measured by SIMS

    International Nuclear Information System (INIS)

    Uyeda, Chiaki; Okano, Jun

    1988-01-01

    Semiquantitative analyses of uranium in fossil bones and teeth were carried out by SIMS. The results show a tendency that uranium concentrations in the fossils increase with the ages of the fossils. It is noticed that fossil bones and teeth having uranium concentration of more than several hundred ppm are not rare. (author)

  10. Fast Plasma Potential Measurements Using an Emissive Probe

    Science.gov (United States)

    Ready, Amanda; Clark, Michael; Endrizzi, Douglass; Forest, Cary; Peterson, Ethan

    2017-10-01

    A heated emissive probe was developed for making direct plasma potential (Vp) measurements in rapidly fluctuating plasmas. Previous experiments on the Big Red Ball (BRB) were hindered by sudden potential drops, making Langmuir measurements of the plasma potential difficult. DC heating of a tungsten filament to emission allowed for fast (4 MHz) floating potential measurements that closely matched Vp. Two BRB experiments currently use the emissive probe. The investigation of unmagnetized, collisionless shocks used plasma potential measurements to study the sub-structure of strong plasma shocks. A separate investigation of emulated magnetospheres in laboratory plasmas used the plasma potential to map the equilibria and instabilities in the electric field of such structures. Results showing electric field measurements and comparison with cold Langmuir measurements will be presented. Future plans for probe modifications and applications to other experiments on the BRB will also be shown.

  11. Measurement of temperature, electric conductivity and density of plasma

    International Nuclear Information System (INIS)

    Vasilevova, I.; Nefedov, A.; Oberman, F.; Urinson, A.

    1982-01-01

    Three instruments are briefly described developed by the High Temperatures Institute of the USSR Academy of Sciences for the measurement of plasma temperature, electric conductivity and density. The temperature measuring instrument uses as a standard a light source whose temperature may significantly differ from plasma temperature because three light fluxes are compared, namely the flux emitted by the plasma, the flux emitted directly by the standard source, and the flux emitted by the standard source after passage through the plasma. The results of measurement are computer processed. Electric conductivity is measured using a coil placed in a probe which is automatically extended for a time of maximally 0.3 seconds into the plasma stream. The equipment for measuring plasma density consists of a special single-channel monochromator, a temperature gauge, a plasma pressure gauge, and of a computer for processing the results of measurement. (Ha)

  12. Laser produced plasma density measurement by Mach-Zehnder interferometry

    International Nuclear Information System (INIS)

    Vaziri, A.; Kohanzadeh, Y.; Mosavi, R.K.

    1976-06-01

    This report describes an optical interferometric method of measuring the refractive index of the laser-produced plasma, giving estimates of its electron density. The plasma is produced by the interaction of a high power pulsed CO 2 laser beam with a solid target in the vacuum. The time varying plasma has a transient electron density. This transient electron density gives rise to a changing plasma refractive index. A Mach-Zehnder ruby laser interferometer is used to measure this refractive index change

  13. Plasma firocoxib concentrations after intra-articular injection of autologous conditioned serum prepared from firocoxib positive horses.

    Science.gov (United States)

    Ortved, K F; Goodale, M B; Ober, C; Maylin, G A; Fortier, L A

    2017-12-01

    Orthobiologics such as autologous conditioned serum (ACS) are often used to treat joint disease in horses. Because ACS is generated from the horse's own blood, any medication administered at the time of preparation would likely be present in stored ACS, which could lead to an inadvertent positive drug test following intra-articular (IA) injection. The main objective of this study was to determine if ACS prepared from firocoxib positive horses could result in detectable plasma concentrations of the drug following IA injection. Firocoxib was administered to six horses at 0.1mg/kg PO twice at a 24h interval. Blood was obtained at 4h following the second dose and transferred to a separate syringe (Arthrex IRAP II) for ACS preparation. Plasma and ACS concentrations of firocoxib were analysed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). When horses were confirmed firocoxib negative, 7.5mL of ACS was injected into both tarsocrural joints. Blood samples were collected at 0, 4, 8, 12, 24, and 48h, and firocoxib concentration was measured. Mean (±standard error of the mean, SEM) plasma concentration of firocoxib 4h following the second dose was 33.3±4.72ng/mL. Mean (±SEM) firocoxib concentration in ACS was 35.4±4.47ng/mL. Fourteen days following the second and last dose of firocoxib, mean plasma concentration was below the lower limit of detection (LOD=1ng/mL) in all horses. Following IA injection of ACS, plasma concentrations of firocoxib remained below LOD at all times in all horses. ACS generated from horses with therapeutic plasma concentrations of firocoxib did not contain sufficient firocoxib to lead to a positive plasma drug test following IA administration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Electrical Measurements on a Moving Argon Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, A. A.M.; Howatson, A. M. [Oxford University (United Kingdom)

    1966-10-15

    Experimental current-voltage characteristic curves were obtained for a moving argon plasma at two stations in an electrically-driven 5 cm shock tube. The standard energy was 1 kj and the base pressure 10 torr, giving a shock of about Mach 4. The measurements were made on the highly-ionized driver gas which followed the shock at speeds between 800 and 1100 m/sec. Two types of electrode were used. One comprised circular solid electrodes of aluminium, molybdenum or stainless steel so machined as to be quite flush with the tube wall; the other comprised filaments of tungsten wire which were immersed in the free stream and could be used cold or heated for thermionic emission. Characteristics were obtained both for applied voltages and for MHD-generated voltages; for the latter a magnetic field of good uniformity up to 0.9 Wb/m{sup 2} was used. The results were always markedly dependent on the surface condition of the electrodes. For consistent results the flush electrodes had to be cleaned carefully by hand after every third discharge, while the filament electrodes were thermionically cleaned before every discharge. In general the cold electrode characteristics for applied voltage showed three distinct regions: a current increase such as would be expected from a double probe; a saturation region; and a linear increase, in order of increasing voltage. For the flush electrodes another apparent saturation was found before, finally, the transition to an arc-type discharge. The first saturation current for flush electrodes corresponded to a random ion current much less than that estimated to exist away from the tube walls, as is expected from a consideration of diffusion through a boundary layer. The value of the current varied somewhat with the electrode material. For the cold filaments, the saturation current density was of the same order as for the flush electrodes. From the linear region of the curves, an effective plasma conductivity was obtained. For comparison, the

  15. Limited sampling strategy for determining metformin area under the plasma concentration-time curve

    DEFF Research Database (Denmark)

    Santoro, Ana Beatriz; Stage, Tore Bjerregaard; Struchiner, Claudio José

    2016-01-01

    AIM: The aim was to develop and validate limited sampling strategy (LSS) models to predict the area under the plasma concentration-time curve (AUC) for metformin. METHODS: Metformin plasma concentrations (n = 627) at 0-24 h after a single 500 mg dose were used for LSS development, based on all su...

  16. Plasma fibrinogen and factor VII concentrations in adults after prenatal exposure to famine

    NARCIS (Netherlands)

    Roseboom, T. J.; van der Meulen, J. H.; Ravelli, A. C.; Osmond, C.; Barker, D. J.; Bleker, O. P.

    2000-01-01

    To assess the effect of maternal malnutrition during different stages of gestation on plasma concentrations of fibrinogen and factor VII, we investigated 725 people, aged 50 years, born around the time of the Dutch famine 1944-5. After adjustment for sex, plasma fibrinogen concentrations differed by

  17. Plasma carotenoid concentrations in relation to acute respiratory infections in elderly people

    NARCIS (Netherlands)

    Graat, J.M.; Kok, F.J.; Schouten, E.G.

    2004-01-01

    A high plasma carotenoid concentration could improve the immune response and result in decreased risk of infectious diseases. However, data on the relationship of plasma carotenoid concentration with acute respiratory infections, which occur frequently in elderly people, are scarce. We investigated,

  18. Plasma androgen concentrations in initial samples from spotted ...

    African Journals Online (AJOL)

    1990-01-31

    Jan 31, 1990 ... initial samples, the immobilization stress response and the response to exogenous GnRH administration, for ... the sex-specific differences in plasma androgens is confounded by other variables such as the reproductive.

  19. Plasma concentrations of endothelial vasoactive substances in clinically healthy subjects. associations with urinary albumin excretion and ambulatory blood pressure

    DEFF Research Database (Denmark)

    Clausen, P; Jensen, J S; Jensent, G

    2000-01-01

    controls with normoalbuminuria. Plasma concentration of ET-1 was measured using an ELISA method and plasma concentration of nitrate/nitrite using a photometric method. Twenty-four-hour blood pressure was measured using a portable recorder (TM-2421). No significant differences in the concentrations...... of nitrate/nitrite and ET-1 were found between the groups, e.g. 21 (10-105) vs. 18 (11 -152) (p=0.33) and 0.98 (0.58 1.95) vs. 1.10 (0.54 -1.50) (p = 0.27), respectively. However, plasma nitrate/nitrite was significantly positively correlated to systolic and diastolic blood pressure in subjects...... in clinically healthy subjects. However, nitrate/nitrite is positively correlated to BP only in subjects with normoalbuminuria, and ET-1 is positively correlated to BP only in subjects with elevated UAE....

  20. Plasma pharmacokinetics and synovial concentrations of S-flurbiprofen plaster in humans.

    Science.gov (United States)

    Yataba, Ikuko; Otsuka, Noboru; Matsushita, Isao; Kamezawa, Miho; Yamada, Ichimaro; Sasaki, Sigeru; Uebaba, Kazuo; Matsumoto, Hideo; Hoshino, Yuichi

    2016-01-01

    The purpose of this study is to investigate the pharmacokinetics and deep tissue penetration capability of the newly developed S-flurbiprofen plaster (SFPP) in humans. Study 1: SFPP tape-type patch (2-60 mg) was applied to the lower back for 24 h in healthy adult volunteers. S-flurbiprofen (SFP) plasma concentration was measured over time to examine SFP pharmacokinetics. Study 2: SFPP (20 mg) was applied for 12 h to the affected knee of osteoarthritis (OA) patients who were scheduled for total knee arthroplasty. Deep tissues (synovial tissue and synovial fluid) were collected during surgery to compare SFP concentrations after application of SFPP or a commercially available flurbiprofen (FP) gel-type patch. Study 1: The plasma concentration of SFP was sustained during 24-h topical application of the SFPP, showing a high percutaneous absorption ratio of 51.4-72.2 %. Cmax and AUC0-∞ were dose-proportional. Study 2: After application of the SFPP for 12 h, SFP concentrations in the synovial tissue and synovial fluid were 14.8-fold (p = 0.002) and 32.7-fold (p < 0.001) higher, respectively, than those achieved by the FP patch. Sustained plasma concentration of SFP and high percutaneous absorption ratio was observed after 24-h topical application of the SFPP. Compared to the FP patch, the SFPP showed superior percutaneous absorption and greater tissue penetration of SFP into the synovial tissue. Greater tissue penetration of the SFPP seemed to be primarily due to its formulation. Thus, SFPP is expected to show higher efficacy for the treatment of knee OA.

  1. Associations between marine food consumption and plasma concentrations of POPs in a Norwegian coastal population.

    Science.gov (United States)

    Rylander, Charlotta; Sandanger, Torkjel Manning; Brustad, Magritt

    2009-02-01

    There are strong indications that a moderate intake of fatty fish decreases the risk of cardiovascular diseases due to its content of omega-3 fatty acids. Other studies indicate that fatty fish consumption increase the body burden of Persistent Organic Pollutants (POPs) and may thereby increase the risk of negative health effects. Many of the latter studies are based on POP analysis of fatty fish, from which a recommended daily intake for humans has been calculated based on the no-observed adverse effect level (NOAEL) obtained from animal studies. Studies investigating associations between human plasma concentrations of POPs and intake of marine food show deviating results. In this study we investigated associations between self-reported intake of marine food (fatty fish, fish liver, fish liver oil, seagull eggs and halibut) and plasma concentrations of POPs. The study group consisted of 44 women and 16 men from northern Norway with a marine based diet. In addition to donate blood samples, the participants answered a detailed food frequency questionnaire with special emphasis on marine food consumption. Concentrations of 25 different POPs were measured in plasma. PCB 153 and p'p-DDE were the most ubiquitous PCB and chlorinated pesticide and the geometric mean concentrations were 73 ng/g lipids and 116 ng/g lipids respectively. The main findings in this study were that age, gender and intake of fresh fish liver oil were significant predictors of three of the most common PCBs and trans-Nonachlor in this study group. In addition, intake of seagull eggs influenced the concentration of PCB 180. However, even though the participants had a high intake of marine food they did not have elevated levels of POPs compared to other study groups. Intake of fatty fish did not significantly affect the body burden of POPs in this study group.

  2. Plasma concentrations resulting from florfenicol preparations given to pigs in their drinking water.

    Science.gov (United States)

    Gutiérrez, L; Vargas, D; Ocampo, L; Sumano, H; Martinez, R; Tapia, G

    2011-09-01

    Florfenicol administered through the drinking water has been recommended as a metaphylactic antibacterial drug to control outbreaks of respiratory diseases in pigs caused by strains of Actinobacillus pleuropneumoniae and Pasteurella multocida, yet it is difficult to pinpoint in practice when the drug is given metaphylactically or therapeutically. Further, pigs are likely to reject florfenicol-medicated water, and plasma concentrations of the drug are likely to be marginal for diseases caused by Escherichia coli, Klebsiella pneumoniae, and Staphylococcus aureus. The reported minimal inhibitory concentration (MIC) values for these organisms show a breakpoint of 2 to 3 μg/mL. An experiment was conducted during September and October 2009. One hundred twenty healthy crossbred pigs (Landrace-Yorkshire), weighing 23 ± 6.2 kg, were used in this trial. They were randomly assigned to 5 groups, with 3 replicates of 8 animals/group. Two commercial preparations of florfenicol were administered through the drinking water at 2 concentrations (0.01 and 0.015%). Water intake was measured before and after medication, and plasma concentrations of florfenicol were determined by HPLC. Considerable rejection of florfenicol-medicated water was observed. However, plasma florfenicol concentrations were of a range sufficient for a methaphylaxis approach to preventing disease by bacteria, with MIC breakpoints of ≤ 0.25 μg/mL. Decreased efficacy as a metaphylactic medication should be expected for bacteria with MIC >0.25 μg/mL, considering the reported existence of bacteria resistant to florfenicol and the natural resistance of Streptococcus suis or E. coli to this drug.

  3. Increased plasma concentration of serum amyloid P component in centenarians with impaired cognitive performance

    DEFF Research Database (Denmark)

    Nybo, M; Olsen, H; Jeune, B

    1998-01-01

    these to the cognitive performance evaluated by Mini Mental State Examination (MMSE). We observed a significantly (p gender-matched controls (32.8+/-11.4 microg/ml). Six severely demented centenarians had an even......Serum amyloid P component (SAP) binds to all amyloid fibrils including those in the plaques and tangles of Alzheimer patients. To investigate whether the plasma SAP concentration correlated to cognitive impairment, we measured SAP levels in blood samples from 41 centenarians and compared...... higher SAP concentration (60.2 microg/ml), while the subgroup of cognitive intact centenarians (MMSE score >24) showed a normal SAP concentration (38.4+/-9.3 microg/ml). No dehydration or hepatic dysfunction was demonstrable in the centenarians. We conclude that the centenarians with impaired cognitive...

  4. Plasma carotenoid concentrations of infants are increased by feeding a milk-based infant formula supplemented with carotenoids.

    Science.gov (United States)

    Mackey, Amy D; Albrecht, Daniel; Oliver, Jeffery; Williams, Timberly; Long, Amy C; Price, Pamela T

    2013-06-01

    Human milk is the gold standard of infant nutrition and is a source of important substances, including carotenoids. Infant formulas are designed to mimic the composition and/or performance of human milk, although currently carotenoids are not routinely added to US infant formulas. The aim of this study was to assess plasma concentrations of β-carotene, lutein and lycopene 56 days after feeding infants milk-based infant formula without (CTRL) or with different concentrations of added carotenoids (L1 and L2). Plasma carotenoid concentrations increased in infants fed carotenoid-supplemented formulas as compared with the control formula with no added carotenoids. At study day 56, infants fed the supplemented formulas (L1 and L2) had mean plasma lutein, β-carotene and lycopene concentrations that were within the range of a concurrent group of human milk-fed infants (HM). Anthropometric measurements were comparable among all study groups. Plasma carotenoid concentrations of infants fed the supplemented formulas were within the range of the HM group and are consistent with reported plasma carotenoid ranges in human milk-fed infants. The experimental formulas were well tolerated and anthropometric measurements were comparable among all study groups. © 2012 Society of Chemical Industry.

  5. Measurement of performance parameters of plasma source for plasma opening switch on Qiangguang-Ⅰ generator

    International Nuclear Information System (INIS)

    Luo Weixi; Zeng Zhengzhong; Lei Tianshi; Wang Liangping; Hu Yixiang; Sun Tieping; Huang Tao

    2012-01-01

    The plasma source (cable guns) of the plasma opening switch (POS) on Qiangguang Ⅰ generator was chosen as the study object. The plasma source performance was investigated by using charge collectors. Experimental results show that the plasma ejection density is positively correlated with the structural parameter, the distance between gun core tip and muzzle plane, and the plasma ejection velocity is negatively correlated with the parameter. The increasing rate of plasma ejection density is less than that of drive current. As far as a plasma source with tens of cable plasma guns is concerned, the influence of single cable gun's discharge dispersancy on plasma uniformity is little. Analysis of uncertainty shows that the uncertainty of measurement can be reduced by increasing the number of experiments and averaging the results. The combined standard uncertainty of plasma ejection density is less than 10%. (authors)

  6. Relation of plasma tryptophan concentrations during pregnancy to maternal sleep and mental well-being: The GUSTO cohort.

    Science.gov (United States)

    van Lee, Linde; Cai, Shirong; Loy, See Ling; Tham, Elaine K H; Yap, Fabian K P; Godfrey, Keith M; Gluckman, Peter D; Shek, Lynette P C; Teoh, Oon Hoe; Goh, Daniel Y T; Tan, Kok Hian; Chong, Yap Seng; Meaney, Michael J; Chen, Helen; Broekman, Birit F P; Chong, Mary F F

    2018-01-01

    Evidence suggests a relation between plasma tryptophan concentrations and sleep and mental well-being. As no studies have been performed in pregnant women, we studied the relation of plasma tryptophan concentrations during pregnancy with sleep quality, and mood during and after pregnancy. Pregnant women (n = 572) from the Growing Up in Singapore Towards healthy Outcomes study completed the Pittsburgh Sleep Quality Index (PSQI), the Edinburgh Postnatal Depression Scale (EPDS) and the State-Trait Anxiety Inventory (STAI) at 26-28 weeks gestation and three months post-delivery. Plasma tryptophan concentrations were measured at 26-28 weeks gestation. Poisson regressions estimated prevalence ratios (PR) for the association between tryptophan and poor sleep quality (PSQI global score > 5), probable antenatal depression (EPDS ≥ 15) and probable anxiety (STAI-state ≥ 41) were calculated adjusting for covariates. Mean plasma tryptophan concentrations was 48.0µmol/L (SD: 8.09). Higher plasma tryptophan concentrations were associated with a lower prevalence of antenatal poor sleep quality adjusting for covariates [PR: 0.88 (95% CI 0.80, 0.97) per 10µmol/L], especially in those participants who also suffered from anxiety symptoms [PR: 0.80 (95% CI 0.67, 0.95)]. No associations were observed between tryptophan concentrations during pregnancy and postnatal sleep quality or mental well-being. Subjective measures were used to assess sleep and mental well-being. We observed that higher plasma tryptophan concentrations were associated with a 12% lower prevalence of poor sleep quality during pregnancy, in particular among those with anxiety symptoms. These findings suggest the importance of having adequate tryptophan concentrations during pregnancy. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Differential Responses of Plasma Adropin Concentrations To Dietary Glucose or Fructose Consumption In Humans.

    Science.gov (United States)

    Butler, Andrew A; St-Onge, Marie-Pierre; Siebert, Emily A; Medici, Valentina; Stanhope, Kimber L; Havel, Peter J

    2015-10-05

    Adropin is a peptide hormone encoded by the Energy Homeostasis Associated (ENHO) gene whose physiological role in humans remains incompletely defined. Here we investigated the impact of dietary interventions that affect systemic glucose and lipid metabolism on plasma adropin concentrations in humans. Consumption of glucose or fructose as 25% of daily energy requirements (E) differentially affected plasma adropin concentrations (P Glucose consumption reduced plasma adropin from 3.55 ± 0.26 to 3.28 ± 0.23 ng/ml (N = 42). Fructose consumption increased plasma adropin from 3.63 ± 0.29 to 3.93 ± 0.34 ng/ml (N = 45). Consumption of high fructose corn syrup (HFCS) as 25% E had no effect (3.43 ± 0.32 versus 3.39 ± 0.24 ng/ml, N = 26). Overall, the effect of glucose, HFCS and fructose on circulating adropin concentrations were similar to those observed on postprandial plasma triglyceride concentrations. Furthermore, increases in plasma adropin levels with fructose intake were most robust in individuals exhibiting hypertriglyceridemia. Individuals with low plasma adropin concentrations also exhibited rapid increases in plasma levels following consumption of breakfasts supplemented with lipids. These are the first results linking plasma adropin levels with dietary sugar intake in humans, with the impact of fructose consumption linked to systemic triglyceride metabolism. In addition, dietary fat intake may also increase circulating adropin concentrations.

  8. Plasma vs heart tissue concentration in humans - literature data analysis of drugs distribution.

    Science.gov (United States)

    Tylutki, Zofia; Polak, Sebastian

    2015-03-12

    Little is known about the uptake of drugs into the human heart, although it is of great importance nowadays, when science desires to predict tissue level behavior rather than to measure it. Although the drug concentration in cardiac tissue seems a better predictor for physiological and electrophysiological changes than its level in plasma, knowledge of this value is very limited. Tissue to plasma partition coefficients (Kp) come to rescue since they characterize the distribution of a drug among tissues as being one of the input parameters in physiologically based pharmacokinetic (PBPK) models. The article reviews cardiac surgery and forensic medical studies to provide a reference for drug concentrations in human cardiac tissue. Firstly, the focus is on whether a drug penetrates into heart tissue at a therapeutic level; the provided values refer to antibiotics, antifungals and anticancer drugs. Drugs that directly affect cardiomyocyte electrophysiology are another group of interest. Measured levels of amiodarone, digoxin, perhexiline and verapamil in different sites in human cardiac tissue where the compounds might meet ion channels, gives an insight into how these more lipophilic drugs penetrate the heart. Much data are derived from postmortem studies and they provide insight to the cardiac distribution of more than 200 drugs. The analysis depicts potential problems in defining the active concentration location, what may indirectly suggest multiple mechanisms involved in the drug distribution within the heart. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Neutron measurements as fusion plasma diagnostics

    International Nuclear Information System (INIS)

    Nishitani, Takeo; Hoek, M.

    1993-01-01

    Neutron measurements play important roles as the diagnostics of many aspects of the plasma in large tokamak devices such as JT-60U and JET. In the d-d discharges of JT-60U, the most important application of the neutron measurement is the investigation of the fusion performance using fission chambers. The ion velocity distribution function, and the triton slowing down are investigated by the neutron spectrometer and the 14 MeV neutron detector, respectively. TANSY is a combined proton-recoil and neutron time-of flight spectrometer for 14 MeV neutrons to be used during the d-t phase at JET. The detection principle is based on the measurements of the flight time of a scattered initial neutron and the energy of a corresponding recoil proton. The scattering medium is a polyethylene foil. The resolution and efficiency, using a thin foil (0.95 mg/cm 2 ), is 155 keV and 1.4x10 -5 cm 2 , respectively. (author)

  10. Concentrations in plasma clozapine levels in schizophrenic and schizoaffective patients.

    Science.gov (United States)

    Iglesias García, Celso; Iglesias Alonso, Ana; Bobes, Julio

    There is great variability in plasma levels of clozapine. The objective of this study is to know the characteristics of patients treated with clozapine and the relationship between them and the variability of plasma levels. Descriptive, cross-sectional study of all patients currently treated with clozapine in a Psychiatric Service with a diagnosis of schizophrenic psychosis or schizoaffective disorder. The present study assessed physical situation, psychopathology and functionality of the patients and explored the associations and correlations between clinical variables and plasma levels. We studied 39 patients, predominantly men, with negative and depressive symptoms and cardiovascular risk factors (metabolic syndrome and smoking). Significant variability in dose and even greater in clozapine levels were observed. The levels of clozapine at equal doses/kg of body weight were higher in non-smokers, they had positive correlation with BMI and negative correlation with systolic BP, disruptive behaviors and number of cigarettes consumed. Plasma level monitoring clozapine is an important tool to avoid clozapine plasma levels monitoring and minimize undesirable clinical situations (metabolic syndrome, sedation, negative symptoms and functional impairment). It is also important to control the effects of a smoking habit for optimum drug bioavailability. Copyright © 2017 SEP y SEPB. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Measuring Concentration in Data with an Exogenous Order

    OpenAIRE

    Abedieh, Jasmin; Groll, Andreas; Eugster, Manuel J. A.

    2013-01-01

    Concentration measures order the statistical units under observation according to their market share. However, there are situations where an order according to an exogenous variable is more appropriate or even required. The present article introduces a generalized definition of market concentration and defines a corresponding concentration measure. It is shown that this generalized concept of market concentration satisfies the common axioms of (classical) concentration measures. In an appl...

  12. The plasma leptin concentration is closely associated with the body fat mass in nondiabetic uremic patients

    DEFF Research Database (Denmark)

    Clausen, P; Nielsen, P K; Olgaard, K

    1999-01-01

    filtration rate seemed to have a limited influence on the plasma leptin concentration in nondiabetic uremic subjects matched by body fat mass to controls. The plasma leptin concentration was closely associated with the body fat mass, and the leptin level might, therefore, be useful as an indicator of the fat......Plasma leptin is associated with the body mass index and, more precisely, with the body fat mass. Plasma leptin has been found to be elevated in uremic patients. This study aimed at investigating the plasma leptin concentration and associations between plasma leptin, body fat mass, and glomerular.......4 (3.1-59.5) ng/ml versus 5.4 (1.6-47.5) ng/ml (median and range in parentheses; p

  13. Correlation between Behavioural and Psychological Symptoms of Alzheimer Type Dementia and Plasma Homocysteine Concentration

    Directory of Open Access Journals (Sweden)

    Zhanjie Zheng

    2014-01-01

    Full Text Available The relationship between plasma homocysteine and behavioral and psychological symptoms of dementia (BPSD has not been specifically investigated in previous research. In this study, we compared plasma homocysteine (Hcy among 40 Alzheimer’s disease (AD patients with BPSD, 37 AD patients without BPSD, and 39 healthy controls. Our results evidenced that the plasma homocysteine levels in AD patients with BPSD and without BPSD were higher than healthy controls and that the plasma homocysteine concentration in AD patients with BPSD was the highest among the three groups. Significant correlation between plasma homocysteine concentration and cognitive decline and duration of dementia was observed, but there was no correlation between BPSD and cognitive dysfunction or duration of dementia. In conclusion, this study showed for the first time that BPSD were associated with plasma homocysteine concentration in Alzheimer's dementia, and the results supported that hyperhomocysteine may take part in the pathogenesis of BPSD.

  14. Plasma lactate concentration as a prognostic biomarker in dogs with gastric dilation and volvulus.

    Science.gov (United States)

    Mooney, Erin; Raw, Cameron; Hughes, Dez

    2014-09-01

    Initial and serial plasma lactate concentrations can be used to guide decision making in individual dogs with GDV but care is necessary in phrasing conversations with owners. Published data suggests that survival is more likely and the chance of complications less in dogs with an initial plasma lactate of 6 mmol/L makes gastric necrosis and greater expense more likely. However, because of the overlap between groups and the good overall survival rates, exploratory laparotomy should always be recommended irrespective of the plasma lactate concentration. Falls in plasma lactate of greater than ~40% after fluid resuscitation are likely to indicate better survival. If the initial plasma lactate concentration is moderately to severely increased (5->10 mmol/L) and a sustained increase in plasma lactate occurs after fluid resuscitation, the cause should be aggressively pursued. Many dogs with persistent hyperlactatemia over 24-48 hours do not survive. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Blood sampling and hemolysis affect concentration of plasma metabolites

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Pedersen, Lene Juul; Jensen, Margit Bak

    2012-01-01

    design and blood was collected after restraint via vein puncture 1, 4, 11, and 23 h after morning feeding. Plasma samples were categorized as without or with minor or major hemolysis [clear (n = 218), yellow (n = 97), or red (n = 37)] upon centrifugation. Plasma NEFA (P ...Two experiments were carried out to reveal and quantify plasma metabolites that are sensitive to hemolysis and animal stress due to the blood sampling procedure (vein puncture vs. catheter). In Exp. 1, 48 sows were fed 4 diets either once (0800 h) or twice daily (0800 h and 1500 h) in a crossover......, a subset of samples from 24 sows fed twice daily in Exp. 1 was combined with data obtained from 30 sows sampled using jugular vein catheters. All sows in Exp. 2 were fed twice daily (0800 h and 1500 h) and blood samples collected repeatedly 1, 4, 11, and 23 h after morning feeding (other conditions were...

  16. Measurement of the concentration of plasmatic cortisol by competition to the binding protein

    International Nuclear Information System (INIS)

    Okada, H.; Tambascia, M.A.; Wajchenberg, B.L.; Pieroni, R.R.

    1977-01-01

    The concentration of plasmatic cortisol was measured by competition to the binding protein (transcortin), after extracting the samples with dicloromethane. It is a suitable method for clinical routine, 100μl of plasma being used in each analysis. The normal mean +- standard error mean in 8:00 a.m. fasting subjects was 13,62 +- 5,43 μl/100 ml of plasma [pt

  17. Measurements of plasma position in TJ-I Tokamak

    International Nuclear Information System (INIS)

    Qin, J.; Ascasibar, E.; Navarro, A.P.; Ochando, M.A.; Pastor, I.; Pedrosa, M.A.; Rodriguez, L.; Sanchez, J.; Team, TJ-I.

    1994-01-01

    This report presents the experimental measurements of plasma position in TJ-I tokamak by using small magnetic probes. The basis of method has been described in our previous work (1) in which the plasma current is considered as a filament current. The observed relations between the disruptive instabilities and plasma displacements are also show here. (Author) 7 refs

  18. Spectroscopic analysis applied to temperature measurement in plasmas

    International Nuclear Information System (INIS)

    Fieffe-Prevost, P.

    1978-01-01

    The plasma temperature is defined only if the plasma is in a state near thermodynamic equilibrium. This plasma state is analysed in detail and spectroscopic methods for measuring the temperature are discussed. As an application the hydrogen arc of the National Institute of Metrology of the Conservatoire National des Arts et Metiers (Paris) is briefly described [fr

  19. Poloidal rotation velocity measurement in toroidal plasmas via microwave reflectometry

    International Nuclear Information System (INIS)

    Pavlichenko, O.S.; Skibenko, A.I.; Fomin, I.P.; Pinos, I.B.; Ocheretenko, V.L.; Berezhniy, V.L.

    2001-01-01

    Results of experiment modeling backscattering of microwaves from rotating plasma layer perturbed by fluctuations are presented. It was shown that auto- and crosscorrelation of reflected power have a periodicity equal to rotation period. Such periodicity was observed by microwave reflectometry in experiments on RF plasma production on U-3M torsatron and was used for measurement of plasma poloidal rotation velocity. (author)

  20. The relationship between HbA(1c) and fasting plasma glucose in patients with increased plasma liver enzyme measurements

    DEFF Research Database (Denmark)

    Christiansen, R; Rasmussen, L Melholt; Nybo, H

    2012-01-01

    levels of increased liver enzyme concentrations. Methods:  Data from 10 065 patients with simultaneous measurement of HbA(1c) , venous fasting plasma glucose, alanine aminotransferase and γ-glutamyl transferase were extracted from our laboratory database. Correlations were investigated in four patient...

  1. Plasma capric acid concentrations in healthy subjects determined by high-performance liquid chromatography.

    Science.gov (United States)

    Shrestha, Rojeet; Hui, Shu-Ping; Imai, Hiromitsu; Hashimoto, Satoru; Uemura, Naoto; Takeda, Seiji; Fuda, Hirotoshi; Suzuki, Akira; Yamaguchi, Satoshi; Hirano, Ken-Ichi; Chiba, Hitoshi

    2015-09-01

    Capric acid (FA10:0, decanoic acid) is a medium-chain fatty acid abundant in tropical oils such as coconut oil, whereas small amounts are present in milk of goat, cow, and human. Orally ingested FA10:0 is transported to the liver and quickly burnt within it. Only few reports are available for FA10:0 concentrations in human plasma. Fasting (n = 5, male/female = 3/2, age 31 ± 9.3 years old) and non-fasting (n = 106, male/female = 44/62, age 21.9 ± 3.2 years old) blood samples were collected from apparently healthy Japanese volunteers. The total FA10:0 in the plasma were measured by high-performance liquid chromatography after derivatization with 2-nitrophenylhydrazine followed by UV detection. Inter and intra-assay coefficient of variation of FA10:0 assay at three different concentrations ranged in 1.7-3.9 and 1.3-5.4%, respectively, with an analytical recovery of 95.2-104.0%. FA10:0 concentration was below detection limit (0.1 µmol/L) in each fasting human plasma. FA10:0 was not detected in 50 (47.2%) of 106 non-fasting blood samples, while 29 (27.4%) plasma samples contained FA10:0 less than or equal to 0.5 µmol/L (0.4 ± 0.1), and 27 (25.5%) contained it at more than 0.5 µmol/L (0.9 ± 0.3). A half of the non-fasting plasma samples contained detectable FA10:0. This simple, precise, and accurate high-performance liquid chromatography method might be useful for monitoring plasma FA10:0 during medium-chain triglycerides therapy. © The Author(s) 2015.

  2. Plasma L-tryptophan concentration in major depressive disorder: new data and meta-analysis.

    Science.gov (United States)

    Ogawa, Shintaro; Fujii, Takashi; Koga, Norie; Hori, Hiroaki; Teraishi, Toshiya; Hattori, Kotaro; Noda, Takamasa; Higuchi, Teruhiko; Motohashi, Nobutaka; Kunugi, Hiroshi

    2014-09-01

    Tryptophan, an essential amino acid, is the precursor to serotonin and is metabolized mainly by the kynurenine pathway. Both serotonin and kynurenine have been implicated in the pathophysiology of major depressive disorder (MDD). However, plasma tryptophan concentration in patients with MDD has not unequivocally been reported to be decreased, which prompted us to perform a meta-analysis on previous studies and our own data. We searched the PubMed database for case-control studies published until August 31, 2013, using the search terms plasma AND tryptophan AND synonyms for MDD. An additional search was performed for the term amino acid instead of tryptophan. We obtained our own data in 66 patients with MDD (DSM-IV) and 82 controls who were recruited from March 2011 to July 2012. The majority of the patients were medicated (N = 53). Total plasma tryptophan concentrations were measured by the liquid chromatography/mass spectrometry method. We scrutinized 160 studies for eligibility. Original articles that were written in English and documented plasma tryptophan values in patients and controls were selected. We included 24 studies from the literature and our own data in the meta-analysis, which involved a total of 744 patients and 793 controls. Data on unmedicated patients (N = 156) and their comparison subjects (N = 203) were also extracted. To see the possible correlation between tryptophan concentrations and depression severity, meta-regression analysis was performed for 10 studies with the Hamilton Depression Rating Scale 17-item version score. In our case-control study, mean (SD) plasma tryptophan level was significantly decreased in the MDD patients versus the controls (53.9 [10.9] vs 57.2 [11.3] μmol/L; P = .03). The meta-analysis after adjusting for publication bias showed a significant decrease in patients with MDD with a modest effect size (Hedges g, -0.45). However, analysis on unmedicated subjects yielded a large effect (Hedges g, -0.84; P = .00015). We

  3. Plasma-parameter measurements using neutral-particle-beam attenuation

    International Nuclear Information System (INIS)

    Foote, J.H.; Molvik, A.W.; Turner, W.C.

    1982-01-01

    Intense and energetic neutral-particle-beam injection used for fueling or heating magnetically confined, controlled-fusion experimental plasmas can also provide diagnostic measurements of the plasmas. The attenuation of an atomic beam (mainly from charge-exchange and ionization interactions) when passing through a plasma gives the plasma line density. Orthogonal arrays of highly collimated detectors of the secondary-electron-emission type have been used in magnetic-mirror experiments to measure neutral-beam attenuation along chords through the plasma volume at different radial and axial positions. The radial array is used to infer the radial plasma-density profile; the axial array, to infer the axial plasma-density profile and the ion angular distribution at the plasma midplane

  4. Citalopram and escitalopram plasma drug and metabolite concentrations: genome-wide associations.

    Science.gov (United States)

    Ji, Yuan; Schaid, Daniel J; Desta, Zeruesenay; Kubo, Michiaki; Batzler, Anthony J; Snyder, Karen; Mushiroda, Taisei; Kamatani, Naoyuki; Ogburn, Evan; Hall-Flavin, Daniel; Flockhart, David; Nakamura, Yusuke; Mrazek, David A; Weinshilboum, Richard M

    2014-08-01

    Citalopram (CT) and escitalopram (S-CT) are among the most widely prescribed selective serotonin reuptake inhibitors used to treat major depressive disorder (MDD). We applied a genome-wide association study to identify genetic factors that contribute to variation in plasma concentrations of CT or S-CT and their metabolites in MDD patients treated with CT or S-CT. Our genome-wide association study was performed using samples from 435 MDD patients. Linear mixed models were used to account for within-subject correlations of longitudinal measures of plasma drug/metabolite concentrations (4 and 8 weeks after the initiation of drug therapy), and single-nucleotide polymorphisms (SNPs) were modelled as additive allelic effects. Genome-wide significant associations were observed for S-CT concentration with SNPs in or near the CYP2C19 gene on chromosome 10 (rs1074145, P = 4.1 × 10(-9) ) and with S-didesmethylcitalopram concentration for SNPs near the CYP2D6 locus on chromosome 22 (rs1065852, P = 2.0 × 10(-16) ), supporting the important role of these cytochrome P450 (CYP) enzymes in biotransformation of citalopram. After adjustment for the effect of CYP2C19 functional alleles, the analyses also identified novel loci that will require future replication and functional validation. In vitro and in vivo studies have suggested that the biotransformation of CT to monodesmethylcitalopram and didesmethylcitalopram is mediated by CYP isozymes. The results of our genome-wide association study performed in MDD patients treated with CT or S-CT have confirmed those observations but also identified novel genomic loci that might play a role in variation in plasma levels of CT or its metabolites during the treatment of MDD patients with these selective serotonin reuptake inhibitors. © 2014 The British Pharmacological Society.

  5. Measuring brightness temperature distributions of plasma bunches

    International Nuclear Information System (INIS)

    Kirko, V.I.; Stadnichenko, I.A.

    1981-01-01

    The possibility of restoration of brightness temperature distribution along plasma jet on the base of a simple ultra high- speed photography and subsequent photometric treatment is shown. The developed technique has been applied for finding spectral radiation intensity and brightness temperature of plasma jets of a tubular gas-cumulative charge and explosive plasma compressor. The problem of shock wave front has been successfully solved and thus distribution of above parameters beginning from the region preceeding the shock wave has been obtained [ru

  6. Adequate plasma drug concentrations suggest that amoxicillin can be administered by continuous infusion using elastomeric pumps.

    Science.gov (United States)

    Arensdorff, Lyne; Boillat-Blanco, Noémie; Decosterd, Laurent; Buclin, Thierry; de Vallière, Serge

    2017-09-01

    Elastomeric pumps can be useful for the administration of antibiotics in the outpatient setting. To determine amoxicillin degradation in elastomeric pumps, as well as the effectiveness of amoxicillin treatment administered by elastomeric pumps. Antibiotic degradation was measured in elastomeric pumps filled with 6 g of amoxicillin in 240 mL of NaCl 0.9% by drawing samples at 12 h intervals when stored in the fridge for 48 h and when worn around the waist for 24 h. Subsequently nine patients were treated with continuous infusions of 8 or 12 g of amoxicillin per day. Plasma amoxicillin concentrations were measured on each visit to the outpatient parenteral antibiotic therapy unit. Clinical outcome was verified 3 months after the end of treatment. Amoxicillin degradation in elastomeric pumps reached 10% after 48 h in the fridge and an additional 30% when worn around the waist for 24 h. Mean plasma drug concentrations achieved with 12 g of amoxicillin per day were 18.5 mg/L (95% CI 13.5-23.5), which is largely above the MIC of amoxicillin-susceptible bacteria. Nine patients treated for various complicated infections were cured and had no unexpected adverse effects. Adequate plasma drug concentrations and favourable clinical outcomes suggest that amoxicillin can be administered by continuous infusion using elastomeric pumps. This treatment modality does not fulfil formal requirements regarding pharmaceutical stability, but the resulting safety impact in patients is probably limited. Therapeutic drug monitoring and a close clinical follow-up are recommended if this route of administration is chosen. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Studies of radioimmunoassay for plasma aldosterone concentration by immunologic purification and extraction procedure without chromatography

    International Nuclear Information System (INIS)

    Yokoyama, Hisamitsu

    1975-01-01

    After the aldosterone fraction of plasma was specifically absorbed using highly concentrated anti-aldosterone serum(i.e. Ab-II; diluted to 1:50,000), it was applied to the radioimmunoassay: and the separation of the free from the bound fractions was performed by the saturated ammonium sulfate method. Reasonable and satisfactory standard curves were obtained, but attention should be given to environmental factors at measurement, especially to the room temperature in summer. According to our results the mean final recovery for 58 specimens was 41.8+-6.4(SD)% through the overall extraction procedure, and the minimum detectable sensitivity of the standard curve was 10pg. The mean water blank value was 7.02+-2.62 (SD) pg/tube. Possible reasons for the higher blank value than others may have been the reagent or the solvent blank, and/or the insufficient process of immunologic purification by Ad-II for the tritium-labelled aldosterone which was used for recovery and immunoassay. The precision was from 9.4 to 25.3% coefficient of variations; the accuracy and recovery rate were almost satisfactory. In our clinical application, the plasma aldosterone concentration indicated high values in the peripheral and affected adrenal venous blood of patients with primary aldosteronism. In a patient with Bartter's syndrome, hyperreninemia and secondary hyperaldosteronism were observed. Almost all of the patients with Addison's disease and with total adrenalectomy indicated the lowest or undetectable levels. A high level of plasma aldosterone concentration was measured in a patient with edema and chronic renal failure and one with juvenile hypertension associated with an orbital tumor. (JPN)

  8. Studies of radioimmunoassay for plasma aldosterone concentration by immunologic purification and extraction procedure without chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, H [Okayama Univ. (Japan). School of Medicine

    1975-07-01

    After the aldosterone fraction of plasma was specifically absorbed using highly concentrated anti-aldosterone serum(i.e. Ab-II; diluted to 1:50,000), it was applied to the radioimmunoassay: and the separation of the free from the bound fractions was performed by the saturated ammonium sulfate method. Reasonable and satisfactory standard curves were obtained, but attention should be given to environmental factors at measurement, especially to the room temperature in summer. According to our results the mean final recovery for 58 specimens was 41.8+-6.4(SD)% through the overall extraction procedure, and the minimum detectable sensitivity of the standard curve was 10pg. The mean water blank value was 7.02+-2.62 (SD) pg/tube. Possible reasons for the higher blank value than others may have been the reagent or the solvent blank, and/or the insufficient process of immunologic purification by Ad-II for the tritium-labelled aldosterone which was used for recovery and immunoassay. The precision was from 9.4 to 25.3% coefficient of variations; the accuracy and recovery rate were almost satisfactory. In our clinical application, the plasma aldosterone concentration indicated high values in the peripheral and affected adrenal venous blood of patients with primary aldosteronism. In a patient with Bartter's syndrome, hyperreninemia and secondary hyperaldosteronism were observed. Almost all of the patients with Addison's disease and with total adrenalectomy indicated the lowest or undetectable levels. A high level of plasma aldosterone concentration was measured in a patient with edema and chronic renal failure and one with juvenile hypertension associated with an orbital tumor.

  9. Evaluation of plasma fibrinogen concentration as a diagnostic indicator of inflammation in red-eared sliders (Trachemys scripta elegans).

    Science.gov (United States)

    Moore, A Russell; Allender, Matthew C; Mitchell, Mark A; MacNeill, Amy L

    2015-01-15

    To critically evaluate plasma fibrinogen concentration as a diagnostic indicator of inflammation in red-eared sliders (Trachemys scripta elegans). Prospective induced-disease model and prospective cross-sectional study. Plasma samples from 12 purpose-bred red-eared sliders and 153 farm-raised red-eared sliders. A modification of the Jacobsson method was developed to measure fibrinogen concentration in platelet-poor plasma from red-eared sliders. Purpose-bred turtles had been inoculated with a ranavirus (n = 4) or sterile PBS solution (8) as part of another study. Farm-raised red-eared sliders were categorized as healthy (n = 138) or overtly ill (15) on the basis of physical examination findings at the time of blood sample collection. Samples from 124 of the 138 healthy red-eared sliders were used to establish a fibrinogen concentration reference interval as measured by the modified Jacobsson method. Fibrinogen concentrations in ranavirus-infected and physically ill turtles were compared with those of healthy turtles to determine whether fibrinogen concentration would be a useful diagnostic indicator of inflammation in red-eared sliders. The modified Jacobsson method was reliably used to measure fibrinogen concentration. The fibrinogen concentration reference interval from healthy reproductively active female red-eared sliders was right skewed. Fibrinogen concentration did not differ significantly between healthy red-eared sliders and ranavirus-infected or overtly ill red-eared sliders. A reference interval for red-eared slider plasma fibrinogen concentration was established and partitioned by sex to account for considerable right skewing observed for females. Fibrinogen concentration was not a useful indicator of inflammation in red-eared sliders with ranavirus infection or other overt illnesses.

  10. Glucose-stimulated insulin response in pregnant sheep following acute suppression of plasma non-esterified fatty acid concentrations

    Directory of Open Access Journals (Sweden)

    Sriskandarajah Nadarajah

    2004-09-01

    Full Text Available Abstract Background Elevated non-esterified fatty acids (NEFA concentrations in non-pregnant animals have been reported to decrease pancreatic responsiveness. As ovine gestation advances, maternal insulin concentrations fall and NEFA concentrations increase. Experiments were designed to examine if the pregnancy-associated rise in NEFA concentration is associated with a reduced pancreatic sensitivity to glucose in vivo. We investigated the possible relationship of NEFA concentrations in regulating maternal insulin concentrations during ovine pregnancy at three physiological states, non-pregnant, non-lactating (NPNL, 105 and 135 days gestational age (dGA, term 147+/- 3 days. Methods The plasma concentrations of insulin, growth hormone (GH and ovine placental lactogen (oPL were determined by double antibody radioimmunoassay. Insulin responsiveness to glucose was measured using bolus injection and hyperglycaemic clamp techniques in 15 non-pregnant, non-lactating ewes and in nine pregnant ewes at 105 dGA and near term at 135 dGA. Plasma samples were also collected for hormone determination. In addition to bolus injection glucose and insulin Area Under Curve calculations, the Mean Plasma Glucose Increment, Glucose Infusion Rate and Mean Plasma Insulin Increment and Area Under Curve were determined for the hyperglycaemic clamp procedures. Statistical analysis of data was conducted with Students t-tests, repeated measures ANOVA and 2-way ANOVA. Results Maternal growth hormone, placental lactogen and NEFA concentrations increased, while basal glucose and insulin concentrations declined with advancing gestation. At 135 dGA following bolus glucose injections, peak insulin concentrations and insulin area under curve (AUC profiles were significantly reduced in pregnant ewes compared with NPNL control ewes (p Conclusions Results suggest that despite an acute suppression of circulating NEFA concentrations during pregnancy, the associated steroids and hormones

  11. Plasma vitamin C concentration in pregnant women with ...

    African Journals Online (AJOL)

    Background: Oxidative stress plays a role in the aetiology of pre-eclampsia and vitamin C may prevent pre-eclampsia. Objective: To determine the association between plasma vitamin C and pre-eclampsia in Mulago Hospital, Kampala, Uganda. Methods: This case-control study was conducted at Mulago Hospital from 1st ...

  12. Hepatitis C virus infection influences the S-methadone metabolite plasma concentration.

    Directory of Open Access Journals (Sweden)

    Shiow-Ling Wu

    Full Text Available Heroin-dependent patients typically contract hepatitis C virus (HCV at a disproportionately high level due to needle exchange. The liver is the primary target organ of HCV infection and also the main organ responsible for drug metabolism. Methadone maintenance treatment (MMT is a major treatment regimen for opioid dependence. HCV infection may affect methadone metabolism but this has rarely been studied. In our current study, we aimed to test the hypothesis that HCV may influence the methadone dosage and its plasma metabolite concentrations in a MMT cohort from Taiwan.A total of 366 MMT patients were recruited. The levels of plasma hepatitis B virus (HBV, HCV, human immunodeficiency virus (HIV antibodies (Ab, liver aspartate aminotransferase (AST and alanine aminotransferase (ALT, as well as methadone and its metabolite 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP were measured along with the urine morphine concentration and amphetamine screening.Of the 352 subjects in our cohort with HCV test records, 95% were found to be positive for plasma anti-HCV antibody. The liver functional parameters of AST (Wilcoxon Rank-Sum test, P = 0.02 and ALT (Wilcoxon Rank-Sum test, P = 0.04, the plasma methadone concentrations (Wilcoxon Rank-Sum test, P = 0.043 and the R-enantiomer of methadone concentrations (Wilcoxon Rank-Sum test, P = 0.032 were significantly higher in the HCV antibody-positive subjects than in the HCV antibody-negative patients, but not the S-EDDP/methadone dose ratio. The HCV levels correlated with the methadone dose (β= 14.65 and 14.13; P = 0.029 and 0.03 and the S-EDDP/methadone dose ratio (β= -0.41 and -0.40; P = 0.00084 and 0.002 in both univariate and multivariate regression analyses.We conclude that HCV may influence the methadone dose and plasma S-EDDP/methadone dose ratio in MMT patients in this preliminary study.

  13. Methodological issues in assessing plasma 25-hydroxyvitamin D concentration in newborn infants.

    Science.gov (United States)

    Gallo, Sina; Comeau, Kathryn; Agellon, Sherry; Vanstone, Catherine; Sharma, Atul; Jones, Glenville; L'abbé, Mary; Khamessan, Ali; Weiler, Hope; Rodd, Celia

    2014-04-01

    Although no gold standard exists, liquid chromatography tandem mass spectrometry (LC-MS/MS) is a precise and accurate method for the analysis of plasma 25-hydroxyvitamin D (25(OH)D). Immunoassays are more readily available and require small volume sampling, ideal for infant testing. The objective was to compare two commercially available immunoassays for measuring circulating 25(OH)D concentration in infant plasma against LC-MS/MS. Capillary blood samples from 103 infants were analyzed for plasma 25(OH)D using an enzyme immunoassay (EIA, Octeia, IDS Ltd.) and radioimmunoassay (RIA, DiaSorin). Plasma 25(OH)D(3), C-3 epimer of 25(OH)D(3) (3-epi-25(OH)D(3)) and 24,25-dihydroxyvitamin D (24,25(OH)(2)D(3)) were measured on the same samples using LC-MS/MS. To establish whether plasma 24,25(OH)(2)D(3) or 3-epi-25(OH)D(3) interferes with these immunoassay results, the zero 25(OH)D calibrator from each assay kit was spiked with increasing amounts of 24,25(OH)(2)D(3) or 3-epi-25(OH)D(3). Classifying infants below the common vitamin D status targets of 50 nmol/L and 75 nmol/L respectively, 58% and 99% fell below using the RIA, 19% and 56% with the EIA and 31% and 76% with LC-MS/MS. Compared to LC-MS/MS, both immunoassays showed poor Bland-Altman limits of agreement for 25(OH)D concentrations (RIA: limits of agreement -27 to +13%; EIA: -12 to +41%), and mountain plots (folded cumulative distribution) depicted significant skew and bias. Spiked 24,25(OH)2D3 concentrations, but not 3-epi-25(OH)D3, appeared as >100% of known values on the EIA but not on the RIA thus, suggesting that the EIA may cross-react with 24,25(OH)(2)D(3) to a greater extent than 3-epi-25(OH)D(3). Two common immunoassays resulted in very different classifications of vitamin D status possibly related to the interference of other vitamin D metabolites. Based on these data, LC-MS/MS assessment of vitamin D status is recommended in young infants (4-6 weeks of age). Copyright © 2014 Elsevier Inc. All rights

  14. Turbidimetry for measurement of radon concentration

    International Nuclear Information System (INIS)

    Wang Huanqiang

    1993-01-01

    This paper describes a turbidimetric technique counting the tracks registered on CR-39 foils exposed to radon. Instead of eyeview through microscope, by using the differential spectrophotometer, strong correlation between the radon cumulative concentration and track turbidence was observed(r=0.999). Under the etching condition of 7.07 mol·L -1 KOH water solution at 80 o C for 16 hr, linear regression showed that the ratio of track turbidence and cumulative concentration of radon exposure was 1.99 x 10 -1 turbidence (KBq m -1 h) -1 and the determination limit was 36 KBq m -3 h. The details of the experiments are represented in this paper. (Author)

  15. Radon concentration measurements in therapeutic spring water

    International Nuclear Information System (INIS)

    Deak, N.; Horvath, A.; Sajo B, L.; Marx, G.

    1996-01-01

    It is believed that people undergoing a curative cycle in a given spa, may receive a dose in the range of 400 mSv/year which is many times the average annual dose so that their risk of lung cancer may increase by 3% or more. To determine the risk due to the natural radioactivity, of the most frequented spas in Budapest (H), we selected four and some others located on the country side being of particular interest. Results of the radon concentration in spring water are presented, with the evidence that some spas have a high radon concentration. We conclude that patients receiving treatment may be exposed to an additional dose in the range of 29-76 mSv/year that at the bronchia could be between 445-1182 mSv/year. (authors). 6 refs., 2 figs., 2 tabs

  16. Twenty-four-hour plasma tryptophan concentrations and ratios are below normal in obese subjects and are not normalized by substantial weight reduction

    DEFF Research Database (Denmark)

    Breum, Leif; Rasmussen, Michael H; Hilsted, Jannik

    2003-01-01

    BACKGROUND: Plasma tryptophan concentrations and the ratio of tryptophan to other large neutral amino acids (plasma tryptophan ratio) are reportedly low in obese subjects. The plasma tryptophan ratio predicts brain tryptophan uptake and serotonin production. If this ratio is low in obese subjects......, serotonin function may also be low. Plasma tryptophan concentrations and ratios have been measured only at single time points in obese subjects; it is not known whether low values for these 2 variables persist throughout a 24-h period. OBJECTIVE: Our objective was to determine whether plasma tryptophan...... concentrations and ratios in obese subjects are lower than those in normal-weight subjects throughout a 24-h period and whether they increase when body weight is reduced. DESIGN: Plasma tryptophan concentrations and ratios were examined in obese subjects before and after weight loss and in nonobese control...

  17. On Debye radius measurement in an unstable gas discharged plasma

    International Nuclear Information System (INIS)

    Shvilkin, B.N.

    1998-01-01

    It is shown that at low concentrations of charged particles conditions can be realized in a magnetized unstable-to-drift plasma for which concentration perturbations are comparable to the concentration itself. The electron temperature is then determined by potential fluctuations, and the drift oscillation wavelength is of the order of the Debye length

  18. Plasma glucose, cholesterol, triglyceride, and glycerol concentrations in the postmature rabbit.

    Science.gov (United States)

    Harlow, A C; Roux, J F; Shapiro, M I

    1980-02-15

    Plasma cholesterol, triglycerides, glycerol, and glucose concentrations were measured in term and postmature rabbits. The data show that the term and postmature mothers have significantly higher glycemia than their fetuses. However, triglyceride and cholesterol concentrations are lower in the postmature mother than in her fetus. Postmature fetuses are characterized by very high plasma triglyceride and cholesterol concentrations. The results demonstrate that postmaturity is accompanied by maternal and fetal lipid metabolic changes related to a decrease in the transfer of maternal fatty acids through the placenta and to a diminution in fetal liver glucose utilization. The postmature fetus is then in a relative state of fasting and must rely on its own supply of fuel (glycogen and lipids) to provide cells for growth and survival. The maternal metabolic changes can possibly be explained by a decreased utilization of maternal substrates by the fetus, the placenta becoming insufficient. The close interrelationship of fetal and maternal lipid metabolism with the activity of the placenta suggests that an accurate knowledge of the metabolic changes taking place in the fetus during alteration of the maternal environment is indispensable to the understanding of the short- and long-term effects of maternal disease on the fetus.

  19. Plasma lactate concentrations in free-ranging moose (Alces alces) immobilized with etorphine.

    Science.gov (United States)

    Haga, Henning A; Wenger, Sandra; Hvarnes, Silje; Os, Oystein; Rolandsen, Christer M; Solberg, Erling J

    2009-11-01

    To investigate plasma lactate concentrations of etorphine-immobilized moose in relation to environmental, temporal and physiological parameters. Prospective clinical study. Fourteen female and five male moose (Alces alces), estimated age range 1-7 years. The moose were darted from a helicopter with 7.5 mg etorphine per animal using projectile syringes and a dart gun. Once immobilized, the moose were approached, a venous blood sample was obtained and vital signs including pulse oximetry were recorded. Diprenorphine was administered to reverse the effects of etorphine. Timing of events, ambient temperature and snow depth were recorded. Blood samples were cooled and centrifuged before plasma was harvested and frozen. The plasma was thawed later and lactate analysed. Data were analysed using descriptive statistics and regression analysis. All animals recovered uneventfully and were alive 12 weeks after immobilization. Mean +/- SD plasma lactate was found to be 9.2 +/- 2.1 mmol L(-1). Plasma lactate concentrations were related positively to snow depth and negatively to time from induction of immobilization to blood sampling. The model that best described the variability in plasma lactate concentrations used induction time (time from firing the dart to the moose being immobilized). The second best model included induction time and snow depth. Plasma lactate concentrations in these etorphine-immobilized moose were in the range reported for other immobilized wild ruminants. Decreasing induction time, which may be related to a more profound etorphine effect, and increasing snow depth possibly may increase plasma lactate concentrations in etorphine-immobilized moose.

  20. Evidence of small-scale magnetic concentrations dragged by vortex motion of solar photospheric plasma

    Science.gov (United States)

    Balmaceda, L.; Vargas Domínguez, S.; Palacios, J.; Cabello, I.; Domingo, V.

    2010-04-01

    Vortex-type motions have been measured by tracking bright points in high-resolution observations of the solar photosphere. These small-scale motions are thought to be determinant in the evolution of magnetic footpoints and their interaction with plasma and therefore likely to play a role in heating the upper solar atmosphere by twisting magnetic flux tubes. We report the observation of magnetic concentrations being dragged towards the center of a convective vortex motion in the solar photosphere from high-resolution ground-based and space-borne data. We describe this event by analyzing a series of images at different solar atmospheric layers. By computing horizontal proper motions, we detect a vortex whose center appears to be the draining point for the magnetic concentrations detected in magnetograms and well-correlated with the locations of bright points seen in G-band and CN images.

  1. Preliminary report: Measurement of apixaban and rivaroxaban in plasma from bleeding patients

    DEFF Research Database (Denmark)

    Jensen, Kathrine Overgaard Foss; Hansen, Svend Høime; Gøtze, Jens Peter

    2017-01-01

    patients receiving rivaroxaban (n = 91) or apixaban (n = 15) showed agreement and correlation between the methods. Measurement in spiked plasma from patients with active bleeding, however, revealed a 26% overestimation by the assay. Conclusions Our findings show that Biophen is suitable for measuring...... apixaban and rivaroxaban concentrations in plasma. However, our results in patients with active bleeding show an overestimation of 26%. This should be taken into account when assessing possible intoxication with apixaban and rivaroxaban in patients presenting with bleeding....

  2. Determination of plasma albumin concentration in healthy and diseased turtles: a comparison of protein electrophoresis and the bromcresol green dye-binding method.

    Science.gov (United States)

    Müller, Kerstin; Brunnberg, Leo

    2010-03-01

    In reptile medicine, plasma chemistry analysis is widely used for the evaluation of an individual's health status. The standard method for the determination of plasma albumin concentration is protein electrophoresis combined with the determination of total protein concentration, but the bromcresol green (BCG) dye-binding method is also used. The reliability of the BCG method for the measurement of albumin concentration in reptiles is unknown. The aim of this study was to compare the plasma albumin values of turtles obtained by protein electrophoresis and the BCG method. Between March 2008 and September 2008, heparinized plasma samples from 16 clinically healthy and 10 diseased turtles of different species were collected. Plasma albumin concentrations were measured by protein electrophoresis and by the BCG method. The results of the 2 methods were compared using Passing-Bablok regression and Bland-Altman plots. Albumin concentration measured by BCG was weakly correlated with the corresponding protein electrophoretic values in all turtles (r(s)=.610, Palbumin concentration measured with the 2 different methods differed significantly in all turtles (P=.009; Wilcoxon's test) and in healthy turtles (P=.005) but not in diseased animals (P=.241). In the Bland-Altman plot a systematic error was found between the 2 methods in diseased turtles. Measurement of albumin by the BCG dye-binding method may lead to inaccurate results for plasma albumin concentration, especially in ill turtles. Therefore, for health assessment in turtles, albumin should be measured by protein electrophoresis.

  3. Influence of storage conditions on in vitro stability of atrial natriuretic peptide and of anesthesia on plasma atrial natriuretic peptide concentration in cats.

    Science.gov (United States)

    Heishima, Yasuhiro; Hori, Yasutomo; Chikazawa, Seishiro; Kanai, Kazutaka; Hoshi, Fumio; Itoh, Naoyuki

    2016-08-01

    OBJECTIVE To investigate the in vitro stability of atrial natriuretic peptide (ANP) in plasma samples under various storage conditions and the influence of anesthesia on plasma ANP concentration in cats. ANIMALS 1 cat with congestive heart failure and 5 healthy adult mixed-breed cats. PROCEDURES A plasma sample from the cat with heart failure was serially diluted, and dilutional parallelism of ANP concentration was evaluated. Plasma samples containing aprotinin or serum samples from the 5 healthy cats were kept at room temperature (27°C) for ≤ 12 hours. Plasma samples from the same healthy cats were stored at -70°, -20°, or 4°C for ≤ 14 days. Plasma samples were obtained from the healthy cats before and during isoflurane anesthesia. Plasma ANP concentrations were measured at a commercial laboratory by use of a human ANP chemiluminescence assay. RESULTS Intra- and interassay coefficients of variation were 1.5% and 2.5%, respectively, and dilutional parallelism was established. Although ANP concentration decreased by 82.4 ± 13.6% (mean ± SD) after sample storage for 12 hours at room temperature, this decrease was prevented by aprotinin. Plasma ANP concentrations were stable for 7 days at -20°C and for 14 days at -70°C. However, concentrations decreased markedly to 57.6 ± 6.9% at -20°C and to 18.0 ± 3.0% at 4°C after 14 days. Plasma ANP concentration decreased significantly in cats during anesthesia and was correlated with blood pressure. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that aprotinin should be added routinely in preparation of plasma samples from cats for measurement of ANP concentration, and those samples, if stored, should be frozen immediately at ≤ -20°C. General anesthesia or systemic blood pressure may affect plasma ANP concentration in cats.

  4. Baseline Plasma C-Reactive Protein Concentrations and Motor Prognosis in Parkinson Disease.

    Directory of Open Access Journals (Sweden)

    Atsushi Umemura

    Full Text Available C-reactive protein (CRP, a blood inflammatory biomarker, is associated with the development of Alzheimer disease. In animal models of Parkinson disease (PD, systemic inflammatory stimuli can promote neuroinflammation and accelerate dopaminergic neurodegeneration. However, the association between long-term systemic inflammations and neurodegeneration has not been assessed in PD patients.To investigate the longitudinal effects of baseline CRP concentrations on motor prognosis in PD.Retrospective analysis of 375 patients (mean age, 69.3 years; mean PD duration, 6.6 years. Plasma concentrations of high-sensitivity CRP were measured in the absence of infections, and the Unified Parkinson's Disease Rating Scale Part III (UPDRS-III scores were measured at five follow-up intervals (Days 1-90, 91-270, 271-450, 451-630, and 631-900.Change of UPDRS-III scores from baseline to each of the five follow-up periods.Change in UPDRS-III scores was significantly greater in PD patients with CRP concentrations ≥0.7 mg/L than in those with CRP concentrations <0.7 mg/L, as determined by a generalized estimation equation model (P = 0.021 for the entire follow-up period and by a generalized regression model (P = 0.030 for the last follow-up interval (Days 631-900. The regression coefficients of baseline CRP for the two periods were 1.41 (95% confidence interval [CI] 0.21-2.61 and 2.62 (95% CI 0.25-4.98, respectively, after adjusting for sex, age, baseline UPDRS-III score, dementia, and incremental L-dopa equivalent dose.Baseline plasma CRP levels were associated with motor deterioration and predicted motor prognosis in patients with PD. These associations were independent of sex, age, PD severity, dementia, and anti-Parkinsonian agents, suggesting that subclinical systemic inflammations could accelerate neurodegeneration in PD.

  5. Plasma position from ring current measurements in Extrap T1

    International Nuclear Information System (INIS)

    Brunsell, P.; Jin Li.

    1989-11-01

    The inductive coupling between the plasma and the four octupole field coils in the Extrap T1 device is utilized as a means of estimating the plasma position. The current in each octupole ring as well as the plasma current is measured by a Rogowski coil and the ring - plasma mutual inductance is then computed assuming axisymmetric plasma displacements. The obtained position is in agreement with internal magnetic probe measurements. The time - evolution of the plasma position for different external vertical and toroidal field strengths is studied. For the present discharge parameter a vertical field of about .008 T is found to give an almost radially stationary plasma. The results are compared with a simple equilibrium model

  6. Spectroscopic measurements of anode plasma with cryogenic pulsed ion sources

    International Nuclear Information System (INIS)

    Yoneda, H.; Urata, T.; Ohbayashi, K.; Kim, Y.; Horioka, K.; Kasuya, K.

    1987-01-01

    In ion beam diodes, electromagnetic wave is coupled to ion beam. Ion is extracted from anode plasma, which is produced early in the power pulse. However, exact mechanism of anode plasma production, expansion and ion extraction process is unknown. In particularly, anode plasma expansion is seemed to be one of the reasons of rapid impedance collapse of the diode, which is serious problem in high power experiments. Some experimental results showed that anode plasma expansion velocity was about 5 times larger than that inferred from simple thermal velocity. Several explanations for these results were proposed; for example, electron collisionarity in anode plasma, fast neutral gas particle, diamagnetism. To solve this question, it is necessary to measure the characteristic of anode plasma with space and time resolution. The authors made spectroscopic measurements to investigate variety of electron temperature, electron density, expansion velocity of anode plasma with various ion sources

  7. Direct measurement of the plasma response to electrostatic ion waves

    International Nuclear Information System (INIS)

    Sarfaty, M.; DeSouza-Machado, S.; Skiff, F.

    1995-01-01

    Plasma wave-wave and wave-particle interactions are studied in a linear magnetized plasma. The relatively quiet plasma is produced by an argon gas-discharge. The plasma density is n e ≅ 10 9 cm -3 and the electron/ion temperatures are T e ≅ 5eV and T i = 0.05eV. A grid and a four ring antenna, both mounted on a scanning carriage, are used to launch electrostatic ion waves in the plasma. Laser Induced Fluorescence measurements of both the linear and the nonlinear plasma response to the wave fields are presented. The Vlasov-Poisson equations are used to explain the measured zero, first and second order terms of the ion distribution function in the presence of wave fields. In addition to the broadening (heating) of the ion distribution as the authors increase the wave amplitudes, induced plasma flows are observed both along and across the magnetic field

  8. Plasma concentrations of enrofloxacin in African grey parrots treated with medicated water.

    Science.gov (United States)

    Flammer, K; Aucoin, D P; Whitt, D A; Prus, S A

    1990-01-01

    Plasma concentrations of enrofloxacin were measured four times during a 7-day treatment period in African grey parrots that were fed with enrofloxacin-medicated drinking water. Water medicated at doubling doses of 0.09, 0.19, 0.38, 0.75, 1.5, and 3.0 mg/ml achieved mean concentrations (+/- SEM) of 0.10 (+/- 0.05), 0.12 (+/- 0.05), 0.12 (+/- 0.03), 0.15 (+/- 0.05), 0.30 (+/- 0.11), and 0.20 (+/- 0.06) micrograms/ml, respectively. A portion of the administered enrofloxacin was metabolized to an equipotent metabolite, ciprofloxacin. Mean ciprofloxacin concentrations paralleled enrofloxacin concentrations but were lower, ranging from 0.04 to 0.27 micrograms/ml. Acceptance of medicated water was adequate at lower doses; however, at doses of 1.5 and 3.0 mg/ml, acceptance was unsatisfactory, and mean weight loss in these groups was significantly higher than the control group. Based on the concentrations achieved in these preliminary trials and the susceptibility patterns of gram-negative bacteria isolated from psittacine birds, drinking water medicated with enrofloxacin at 0.19-0.75 mg/ml might be effective for treating highly susceptible gram-negative bacterial infections in African grey parrots.

  9. Dyslipidemia and reference values for fasting plasma lipid concentrations in Danish/North-European White children and adolescents

    DEFF Research Database (Denmark)

    Nielsen, Tenna Ruest Haarmark; Lausten-Thomsen, Ulrik; Fonvig, Cilius Esmann

    2017-01-01

    BACKGROUND: Dyslipidemia is reported in 27 - 43% of children and adolescents with overweight/obesity and tracks into adulthood, increasing the risk of cardiovascular morbidity. Cut-off values for fasting plasma lipid concentrations are typically set at fixed levels throughout childhood. The objec......BACKGROUND: Dyslipidemia is reported in 27 - 43% of children and adolescents with overweight/obesity and tracks into adulthood, increasing the risk of cardiovascular morbidity. Cut-off values for fasting plasma lipid concentrations are typically set at fixed levels throughout childhood....... The objective of this cross-sectional study was to generate fasting plasma lipid references for a Danish/North-European White population-based cohort of children and adolescents, and investigate the prevalence of dyslipidemia in this cohort as well as in a cohort with overweight/obesity. METHODS: A population......, and fasting plasma lipid concentrations were measured on all participants. Smoothed reference curves and percentiles were generated using the Generalized Additive Models for Location Scale and Shape package in the statistical software R. RESULTS: In the population-based cohort, plasma concentrations of total...

  10. Recent measurements of electron density profiles of plasmas in PLADIS I, a plasma disruption simulator

    International Nuclear Information System (INIS)

    Bradley, J. III; Sharp, G.; Gahl, J.M. Kuznetsov, V.; Rockett, P.; Hunter, J.

    1995-01-01

    Tokamak disruption simulation experiments are being conducted at the University of New Mexico (UNM) using the PLADIS I plasma gun system. PLADIS I is a high power, high energy coaxial plasma gun configured to produce an intense plasma beam. First wall candidate materials are placed in the beam path to determine their response under disruption relevant energy densities. An optically thick vapor shield plasma has been observed to form above the target surface in PLADIS I. Various diagnostics have been used to determine the characteristics of the incident plasma and the vapor shielding plasma. The cross sectional area of the incident plasma beam is a critical characteristic, as it is used in the calculation of the incident plasma energy density. Recently, a HeNe interferometer in the Mach-Zehnder configuration has been constructed and used to probe the electron density of the incident plasma beam and vapor shield plasma. The object beam of the interferometer is scanned across the plasma beam on successive shots, yielding line integrals of beam density on different chords through the plasma. Data from the interferometer is used to determine the electron density profile of the incident plasma beam as a function of beam radius. This data is then used to calculate the effective beam area. Estimates. of beam area, obtained from other diagnostics such as damage targets, calorimeter arrays and off-axis measurements of surface pressure, will be compared with data from the interferometer to obtain a better estimate of the beam cross sectional area

  11. The effect of 8-week low impact aerobic exercise on plasma fibrinogen concentration in old women

    Directory of Open Access Journals (Sweden)

    Shahla Dehghan

    2013-09-01

    Full Text Available Applied Exercise Physiology focuses on the physiological effects of exercise training on physiological processes, health, and physical well-being. The aim of this study was investigation of effects of 8-week low impact aerobic exercise on plasma fibrinogen concentration in old women. Fibrinogen is one of the most important inflammation factors and a prediction index in cardio vascular diseases. Iranian women especially older ones are generally sedentary because of their traditional and religious believes. Samples were 23 healthy and enable to do physical activity old women of Shahrekord (Chaharmahal va bakhtiary province, Iran retirement home. Subjects were randomly divided to two groups including experimental (n=14 individuals and control (n=11 individuals. First, for assessment of fibrinogen level, 5cc blood samples were obtained after 8 hours nightly fasting from anterior vein in resting condition. Experimental group was participated in 8 week (three times a week LIA training program (15 min in first day with 40% of maximum heart rate until 40 min in last day with 65% of maximum heart rate. All of mentioned measurements repeated at the end of 8 week training. The obtained results showed that 8 week LIA program has significant effect on reduction of old women plasma fibrinogen level (P=0.02. It seems that use of 8 week LIA training has positive effects on improvement of cardiovascular health and prevention of inflammation disease related to plasma fibrinogen level in Iranian old women. Key words: aerobic exercises, old women, fibrinogen.

  12. Plasma homocyst(e)ine concentrations in eclamptic and preeclamptic African women postpartum.

    Science.gov (United States)

    Rajkovic, A; Mahomed, K; Malinow, M R; Sorenson, T K; Woelk, G B; Williams, M A

    1999-09-01

    To examine the relationship between plasma homocyst(e)ine and risk of eclampsia and preeclampsia among sub-Saharan African women who delivered at Harare Maternity Hospital in Zimbabwe. We ran a hospital-based, case-control study at Harare Maternity Hospital, University of Zimbabwe, Harare, Zimbabwe comprising 33 pregnant women with eclampsia and 138 with preeclampsia. Controls were 185 normotensive pregnant women. Plasma was collected postpartum and homocyst(e)ine levels were measured by high-performance liquid chromatography and electrochemical detection. Women with eclampsia or preeclampsia had significantly higher mean homocyst(e)ine levels than normotensive controls (12.54 or 12.77 micromol/L versus 9.93 micromol/L, respectively, Pine distribution (median 13.9 micromol/L) compared with women in the lowest quartile (median 6.2 micromol/L). The corresponding OR for preeclampsia was 4.57. Nulliparas with elevated homocyst(e)ine had a 12.90 times higher risk of preeclampsia compared with multiparas without elevated homocyst(e)ine. Postpartum plasma homocyst(e)ine concentrations are higher among Zimbabwean women with eclampsia and preeclampsia compared with normotensive women.

  13. Correlation between the Plasma Insulin and Glucose Concentration in Normal Korean Adults

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jang Kyu; Sung, Ho Kyung; Kim, Jin Eui [Radiological Research Institute, Seoul (Korea, Republic of)

    1971-09-15

    The correlation between the plasma insulin, and glucose concentration was studied in healthy Korean adults consisting of 20 males and 22 females of 16 to 38 years of age. The blood samples of above subjects were obtained through cubital vein at arbitrary times during their usual working hours. Plasma insulin was assayed by means of double antibody system of radioimmunoassay technics, and blood glucose was determined by means of Van Slyke-Folch method. Results were as follows : 1. There were no differences in the blood sugar levels in relation to the plasma insulin concentration either by sex or age. 2. In the case, when the plasma insulin concentration was within 50 mmuU/ml, the correlation between the insulin, and glucose concentration existed, the ratio of which was expressed as; Plasma glucose concentration (mg/dl)=91.9 + 0.08 X Insulin concentration r=0.62. 3. Insulinogenic index was 12.4%, which was somewhat higher than other reports. 4. It is suggested that the correlation between plasma insulin and glucose concentration could be determined at arbitrary times instead of fasting times.

  14. Effects of betaine intake on plasma homocysteine concentrations and consequences for health

    NARCIS (Netherlands)

    Olthof, Margreet R.; Verhoef, P.

    High plasma concentrations of homocysteine may increase risk of cardiovascular disease. Folic acid lowers plasma homocysteine by 25% maximally, because 5-methyltetrahydrofolate is a methyl donor in the remethylation of homocysteine to methionine. Betaine (trimethylglycine) is also a methyl donor in

  15. Effects of Betaine Intake on Plasma Homocysteine Concentrations and Consequences for Health

    NARCIS (Netherlands)

    Olthof, M.R.; Verhoef, P.

    2005-01-01

    High plasma concentrations of homocysteine may increase risk of cardiovascular disease. Folic acid lowers plasma homocysteine by 25% maximally, because 5-methyltetrahydrofolate is a methyl donor in the remethylation of homocysteine to methionine. Betaine (trimethylglycine) is also a methyl donor in

  16. PFAS concentrations in plasma samples from Danish school children and their mothers

    DEFF Research Database (Denmark)

    Mørck, Thit A; Nielsen, Flemming; Nielsen, Jeanette K S

    2015-01-01

    an association between plasma levels and the age of the mothers and higher levels of plasma PFASs in mothers with low parity. There were no associations between PFAS concentrations and residential area, dietary habits of the participants or with respect to the birth order of the children. The levels...

  17. Chronic effects assessment and plasma concentrations of the {beta}-blocker propranolol in fathead minnows (Pimephales promelas)

    Energy Technology Data Exchange (ETDEWEB)

    Giltrow, Emma [Institute for the Environment, Brunel University, Uxbridge, Middlesex UB8 3PH (United Kingdom); Eccles, Paul D. [Institute for the Environment, Brunel University, Uxbridge, Middlesex UB8 3PH (United Kingdom); Biosciences, School of Health Sciences and Social Care, Brunel University, Uxbridge, Middlesex UB8 3PH (United Kingdom); Winter, Matthew J.; McCormack, Paul J. [AstraZeneca Safety, Health and Environment, Brixham Environmental Laboratory, Freshwater Quarry, Brixham, Devon TQ5 8BA (United Kingdom); Rand-Weaver, Mariann [Biosciences, School of Health Sciences and Social Care, Brunel University, Uxbridge, Middlesex UB8 3PH (United Kingdom); Hutchinson, Thomas H. [Natural Environmental Research Council, Plymouth Marine Laboratory, Prospect Place, The Hoe, Plymouth PL1 3DH (United Kingdom); Sumpter, John P., E-mail: john.sumpter@brunel.ac.uk [Institute for the Environment, Brunel University, Uxbridge, Middlesex UB8 3PH (United Kingdom)

    2009-11-27

    The presence of many human pharmaceuticals in the aquatic environment is now a worldwide concern, yet little is known of the chronic effects that these bioactive substances may be having on aquatic organisms. Propranolol, a non-specific beta adrenoreceptor blocker ({beta}-blocker), is used to treat high blood pressure and heart disease in humans. Propranolol has been found in surface waters worldwide at concentrations ranging from 12 to 590 ng/L. To test the potential for ecologically relevant effects in fish in receiving waters, short-term (21 days) adult reproduction studies were conducted, in which fathead minnows were exposed to nominal concentrations of propranolol hydrochloride [CAS number 318-98-9] ranging from 0.001 to 10 mg/L (measured concentrations typically from 78 to 130%). Exposure of fish to 3.4 mg/L (measured) over 3 days caused 100% mortality or severe toxicity requiring euthanasia. The most sensitive endpoints from the studies were a decrease in hatchability (with regard to the number of days to hatch) and a concentration-related increase in female gonadal somatic index (GSI), giving LOEC{sup hatchability} and LOEC{sup female} {sup GSI} values of 0.1 mg/L. Concentration-related decreases in weights of male fish were also observed, with LOEC{sup m}ale wet weight value of 1.0 mg/L, and the LOEC{sup r}eproduction value was 1.0 mg/L. Collectively, these data do not suggest that propranolol was acting as a reproductive toxin. Plasma concentrations of propranolol in male fish exposed to nominal concentrations of 0.1 and 1.0 mg/L were 0.34 and 15.00 mg/L, respectively, which constitutes 436 and 1546% of measured water concentrations. These compare with predicted concentrations of 0.07 and 0.84 mg/L, and thus to a degree support the use of partition coefficient models for predicting concentrations in plasma in fish. In addition, propranolol plasma concentrations in fish exposed to water concentrations of 0.1 and 1.0 mg/L were greater than the human

  18. Chronic effects assessment and plasma concentrations of the β-blocker propranolol in fathead minnows (Pimephales promelas)

    International Nuclear Information System (INIS)

    Giltrow, Emma; Eccles, Paul D.; Winter, Matthew J.; McCormack, Paul J.; Rand-Weaver, Mariann; Hutchinson, Thomas H.; Sumpter, John P.

    2009-01-01

    The presence of many human pharmaceuticals in the aquatic environment is now a worldwide concern, yet little is known of the chronic effects that these bioactive substances may be having on aquatic organisms. Propranolol, a non-specific beta adrenoreceptor blocker (β-blocker), is used to treat high blood pressure and heart disease in humans. Propranolol has been found in surface waters worldwide at concentrations ranging from 12 to 590 ng/L. To test the potential for ecologically relevant effects in fish in receiving waters, short-term (21 days) adult reproduction studies were conducted, in which fathead minnows were exposed to nominal concentrations of propranolol hydrochloride [CAS number 318-98-9] ranging from 0.001 to 10 mg/L (measured concentrations typically from 78 to 130%). Exposure of fish to 3.4 mg/L (measured) over 3 days caused 100% mortality or severe toxicity requiring euthanasia. The most sensitive endpoints from the studies were a decrease in hatchability (with regard to the number of days to hatch) and a concentration-related increase in female gonadal somatic index (GSI), giving LOEC hatchability and LOEC female GSI values of 0.1 mg/L. Concentration-related decreases in weights of male fish were also observed, with LOEC m ale wet weight value of 1.0 mg/L, and the LOEC r eproduction value was 1.0 mg/L. Collectively, these data do not suggest that propranolol was acting as a reproductive toxin. Plasma concentrations of propranolol in male fish exposed to nominal concentrations of 0.1 and 1.0 mg/L were 0.34 and 15.00 mg/L, respectively, which constitutes 436 and 1546% of measured water concentrations. These compare with predicted concentrations of 0.07 and 0.84 mg/L, and thus to a degree support the use of partition coefficient models for predicting concentrations in plasma in fish. In addition, propranolol plasma concentrations in fish exposed to water concentrations of 0.1 and 1.0 mg/L were greater than the human therapeutic plasma concentration

  19. Measurements of EEDF in recombination dominated afterglow plasma

    Science.gov (United States)

    Plasil, R.; Korolov, I.; Kotrik, T.; Varju, J.; Dohnal, P.; Donko, Z.; Bano, G.; Glosik, J.

    2009-11-01

    Electron energy distribution functions (EEDF) have been measured in decaying plasma in Flowing Afterglow Langmuir Probe (FALP) experiment. The measurements have been carried out in diffusion and recombination governed plasmas used for studies of recombination of KrD+ and H3+ ions.

  20. Measurements of EEDF in recombination dominated afterglow plasma

    Energy Technology Data Exchange (ETDEWEB)

    Plasil, R; Korolov, I; Kotrik, T; Varju, J; Dohnal, P; Glosik, J [Charles University, Faculty of Mathematics and Physics, Department of Surface and Plasma Science, Prague (Czech Republic); Donko, Z; Bano, G, E-mail: radek.plasil@mff.cuni.c [Research Institute for Solid State Physics and Optics, Hungarian Academy of Sciences, Budapest (Hungary)

    2009-11-15

    Electron energy distribution functions (EEDF) have been measured in decaying plasma in Flowing Afterglow Langmuir Probe (FALP) experiment. The measurements have been carried out in diffusion and recombination governed plasmas used for studies of recombination of KrD{sup +} and H{sub 3}{sup +} ions.

  1. Measurements of EEDF in recombination dominated afterglow plasma

    International Nuclear Information System (INIS)

    Plasil, R; Korolov, I; Kotrik, T; Varju, J; Dohnal, P; Glosik, J; Donko, Z; Bano, G

    2009-01-01

    Electron energy distribution functions (EEDF) have been measured in decaying plasma in Flowing Afterglow Langmuir Probe (FALP) experiment. The measurements have been carried out in diffusion and recombination governed plasmas used for studies of recombination of KrD + and H 3 + ions.

  2. Measurement of the argon plasma temperature by use of pyrometer

    International Nuclear Information System (INIS)

    Wang Fanhou; Jing Fuqian

    2002-01-01

    The author describes in detail how to use pyrometer to measure the plasma temperature. The temperatures of shock-generated argon plasmas are given in the present work. Measured results of temperature-pressure curve are compared with calculated results using Saha-Debye-Huckel model, which are in good agreement

  3. Clinical significance of 2 h plasma concentrations of first-line anti-tuberculosis drugs

    DEFF Research Database (Denmark)

    Prahl, Julie B; Johansen, Isik S; Cohen, Arieh S

    2014-01-01

    OBJECTIVES: To study 2 h plasma concentrations of the first-line tuberculosis drugs isoniazid, rifampicin, ethambutol and pyrazinamide in a cohort of patients with tuberculosis in Denmark and to determine the relationship between the concentrations and the clinical outcome. METHODS: After 6......-207 days of treatment (median 34 days) 2 h blood samples were collected from 32 patients with active tuberculosis and from three patients receiving prophylactic treatment. Plasma concentrations were determined using LC-MS/MS. Normal ranges were obtained from the literature. Clinical charts were reviewed...... failure occurred more frequently when the concentrations of isoniazid and rifampicin were both below the normal ranges (P = 0.013) and even more frequently when they were below the median 2 h drug concentrations obtained in the study (P = 0.005). CONCLUSIONS: At 2 h, plasma concentrations of isoniazid...

  4. HPLC for simultaneous quantification of total ceramide, glucosylceramide, and ceramide trihexoside concentrations in plasma

    NARCIS (Netherlands)

    Groener, Johanna E. M.; Poorthuis, Ben J. H. M.; Kuiper, Sijmen; Helmond, Mariette T. J.; Hollak, Carla E. M.; Aerts, Johannes M. F. G.

    2007-01-01

    BACKGROUND: Simple, reproducible assays are needed for the quantification of sphingolipids, ceramide (Cer), and sphingoid bases. We developed an HPLC method for simultaneous quantification of total plasma concentrations of Cer, glucosylceramide (GlcCer), and ceramide trihexoside (CTH). METHODS:

  5. Depolarization Rayleigh scattering as a means of molecular concentration determination in plasmas

    NARCIS (Netherlands)

    Meulenbroeks, R.F.G.; Schram, D.C.; Jaegers, L.J.M.; Sanden, van de M.C.M.

    1992-01-01

    The difference in polarization for Rayleigh scattered radiation on spherically and nonspherically symmetric scattering objects has been used to obtain molecular species concentrations in plasmas of simple composition. Using a Rayleigh scattering diagnostic, the depolarized component of the scattered

  6. Concentration of plasma haptoglobin and symptomatic cerebral vasospasm after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    FAN Yi-mu

    2013-08-01

    Full Text Available The relation of plasma haptoglobin concentration to symptomatic cerebral vasospasm (SCVS after subarachnoid hemorrhage (SAH was investigated. The plasma concentration of haptoglobin was analyzed by enzyme-linked immunosorbent assay (ELISA. SCVS was determined by aggravated headache, deteriorated conscious state a few days after ictus or by new neurologic impairment and new ischemic injuries on repeated CT scans. The mean concentration of plasma haptoglobin in 19 patients with SCVS was (0.29 ± 0.14 g/L, whereas it was (0.78 ± 0.48 g/L in 24 patients without SCVS. These findings may suggest that plasma haptoglobin concentration seems to be associated with the development of SCVS after SAH.

  7. Dynamics of plasma catecholamine and corticosterone concentrations during reinforced and extinguished operant behavior in rats

    NARCIS (Netherlands)

    de Boer, S.F.; de Beun, R; Slangen, J L; van der Gugten, J

    Plasma noradrenaline (NA), adrenaline (A) and corticosterone (CS) concentrations were determined simultaneously in permanently heart-cannulated rats before and during the performance of reinforced and nonreinforced (extinguished) operant behavior. Shortly before the experimental food-reinforced (VI

  8. High plasma uric acid concentration: causes and consequences

    Directory of Open Access Journals (Sweden)

    de Oliveira Erick

    2012-04-01

    Full Text Available Abstract High plasma uric acid (UA is a precipitating factor for gout and renal calculi as well as a strong risk factor for Metabolic Syndrome and cardiovascular disease. The main causes for higher plasma UA are either lower excretion, higher synthesis or both. Higher waist circumference and the BMI are associated with higher insulin resistance and leptin production, and both reduce uric acid excretion. The synthesis of fatty acids (tryglicerides in the liver is associated with the de novo synthesis of purine, accelerating UA production. The role played by diet on hyperuricemia has not yet been fully clarified, but high intake of fructose-rich industrialized food and high alcohol intake (particularly beer seem to influence uricemia. It is not known whether UA would be a causal factor or an antioxidant protective response. Most authors do not consider the UA as a risk factor, but presenting antioxidant function. UA contributes to > 50% of the antioxidant capacity of the blood. There is still no consensus if UA is a protective or a risk factor, however, it seems that acute elevation is a protective factor, whereas chronic elevation a risk for disease.

  9. Effects of acute exposure to increased plasma branched-chain amino acid concentrations on insulin-mediated plasma glucose turnover in healthy young subjects.

    Science.gov (United States)

    Everman, Sarah; Mandarino, Lawrence J; Carroll, Chad C; Katsanos, Christos S

    2015-01-01

    Plasma branched-chain amino acids (BCAA) are inversely related to insulin sensitivity of glucose metabolism in humans. However, currently, it is not known whether there is a cause-and-effect relationship between increased plasma BCAA concentrations and decreased insulin sensitivity. To determine the effects of acute exposure to increased plasma BCAA concentrations on insulin-mediated plasma glucose turnover in humans. Ten healthy subjects were randomly assigned to an experiment where insulin was infused at 40 mU/m2/min (40U) during the second half of a 6-hour intravenous infusion of a BCAA mixture (i.e., BCAA; N = 5) to stimulate plasma glucose turnover or under the same conditions without BCAA infusion (Control; N = 5). In a separate experiment, seven healthy subjects were randomly assigned to receive insulin infusion at 80 mU/m2/min (80U) in association with the above BCAA infusion (N = 4) or under the same conditions without BCAA infusion (N = 3). Plasma glucose turnover was measured prior to and during insulin infusion. Insulin infusion completely suppressed the endogenous glucose production (EGP) across all groups. The percent suppression of EGP was not different between Control and BCAA in either the 40U or 80U experiments (P > 0.05). Insulin infusion stimulated whole-body glucose disposal rate (GDR) across all groups. However, the increase (%) in GDR was not different [median (1st quartile - 3rd quartile)] between Control and BCAA in either the 40U ([199 (167-278) vs. 186 (94-308)] or 80 U ([491 (414-548) vs. 478 (409-857)] experiments (P > 0.05). Likewise, insulin stimulated the glucose metabolic clearance in all experiments (P BCAA in either of the experiments (P > 0.05). Short-term exposure of young healthy subjects to increased plasma BCAA concentrations does not alter the insulin sensitivity of glucose metabolism.

  10. Effects of acute exposure to increased plasma branched-chain amino acid concentrations on insulin-mediated plasma glucose turnover in healthy young subjects.

    Directory of Open Access Journals (Sweden)

    Sarah Everman

    Full Text Available Plasma branched-chain amino acids (BCAA are inversely related to insulin sensitivity of glucose metabolism in humans. However, currently, it is not known whether there is a cause-and-effect relationship between increased plasma BCAA concentrations and decreased insulin sensitivity.To determine the effects of acute exposure to increased plasma BCAA concentrations on insulin-mediated plasma glucose turnover in humans.Ten healthy subjects were randomly assigned to an experiment where insulin was infused at 40 mU/m2/min (40U during the second half of a 6-hour intravenous infusion of a BCAA mixture (i.e., BCAA; N = 5 to stimulate plasma glucose turnover or under the same conditions without BCAA infusion (Control; N = 5. In a separate experiment, seven healthy subjects were randomly assigned to receive insulin infusion at 80 mU/m2/min (80U in association with the above BCAA infusion (N = 4 or under the same conditions without BCAA infusion (N = 3. Plasma glucose turnover was measured prior to and during insulin infusion.Insulin infusion completely suppressed the endogenous glucose production (EGP across all groups. The percent suppression of EGP was not different between Control and BCAA in either the 40U or 80U experiments (P > 0.05. Insulin infusion stimulated whole-body glucose disposal rate (GDR across all groups. However, the increase (% in GDR was not different [median (1st quartile - 3rd quartile] between Control and BCAA in either the 40U ([199 (167-278 vs. 186 (94-308] or 80 U ([491 (414-548 vs. 478 (409-857] experiments (P > 0.05. Likewise, insulin stimulated the glucose metabolic clearance in all experiments (P 0.05.Short-term exposure of young healthy subjects to increased plasma BCAA concentrations does not alter the insulin sensitivity of glucose metabolism.

  11. [Plasma prolactin concentration and the effect of metergoline in pseudopregnant Afghan hounds].

    Science.gov (United States)

    Okkens, A C; Dieleman, S J; Kooistra, H S; Bevers, M M

    2000-02-01

    The effects of metergoline, a 5-hydroxytryptamine (serotinin) antagonist, on the plasma concentrations of prolactin in overtly pseudopregnant Afghan hounds and on the clinical symptoms of overt pseudopregnancy were studied. Plasma concentrations of prolactin and progesterone were determined in six Afghan hounds with signs of overt pseudopregnancy for 2-3 weeks and in three Afghan hounds that were not pseudopregnant at the time of blood sampling. In the overtly pseudopregnant bitches the plasma concentrations of prolactin before treatment (35.5 +/- 8.5 micrograms l-1) were significantly higher than the plasma concentrations of prolactin of the three bitches that were not pseudopregnant (6.3 +/- 0.5 micrograms l-1); the latter values were similar to those of non-psueodopregnant beagle bitches during the total luteal phase. The six pseudopregnant Afghan hounds were treated for 10 days with the antiserotoninergic drug metergoline. At 2 h after the onset of treatment with metergoline, the mean plasma concentration of prolactin had decreased to 10.8 +/- 2.9 micrograms l-1. The plasma concentrations of prolactin continued to decline to 5.4 +/- 1.0 micrograms l-1 at 4 h and to 1.0 +/- 0.1 microgram l-1 during treatment days 3-10. Signs of pseudopregnancy, such as swelling of the mammary glands and digging, decreased during the treatment period. The treatment was associated with mild behavioural side effects such as whimpering and aggressiveness. These side effects are probably not related to suppression of prolactin but are due to a direct effect on serotoninergic pathways in the brain. It is concluded that high plasma concentrations of prolactin are associated with the development and maintenance of pseudopregnancy. The serotonin antagonist metergoline strongly suppresses plasma concentration of prolactine in pseudopregnant dogs and decreases the clinical signs of pseudopregnancy.

  12. Plasma concentrations of prolactin in overtly pseudopregnant Afghan hounds and the effect of metergoline.

    Science.gov (United States)

    Okkens, A C; Dieleman, S J; Kooistra, H S; Bevers, M M

    1997-01-01

    The effect of metergoline, a 5-hydroxytryptamine (serotonin) antagonist, on the plasma concentrations of prolactin in overtly pseudopregnant Afghan hounds and on the clinical symptoms of overt pseudopregnancy were studied. Plasma concentrations of prolactin and progesterone were determined in six Afghan hounds with signs of overt pseudopregnancy for 2-3 weeks and in three Afghan hounds that were not pseudopregnant at the time of blood sampling. In the overtly pseudopregnant bitches the plasma concentrations of prolactin before treatment (35.5 +/- 8.5 micrograms l-1) were significantly higher than the plasma concentrations of prolactin of the three bitches that were not pseudopregnant (6.3 +/- 0.5 micrograms l-1); the latter values were similar to those of non-pseudopregnant beagle bitches during the total luteal phase. The six pseudopregnant Afghan hounds were treated for 10 days with the antiserotoninergic drug metergoline. At 2 h after the onset of treatment with metergoline, the mean plasma concentration of prolactin had decreased to 10.8 +/- 2.9 micrograms l-1. The plasma concentrations of prolactin continued to decline to 5.4 +/- 1.0 micrograms l-1 at 4 h and to 1.0 +/- 0.1 microgram l-1 during treatment days 3-10. Signs of pseudopregnancy, such as swelling of the mammary glands and digging, decreased during the treatment period. The treatment was associated with mild behavioural side effects such as whimpering and aggressiveness. These side effects are probably not related to suppression of prolactin but are due to a direct effect on serotoninergic pathways in the brain. It is concluded that high plasma concentrations of prolactin are associated with the development and maintenance of pseudopregnancy. The serotonin antagonist metergoline strongly suppresses plasma concentrations of prolactin in pseudopregnant dogs and decreases the clinical signs of pseudopregnancy.

  13. Spectroscopic measurements of plasma emission light for plasma-based acceleration experiments

    International Nuclear Information System (INIS)

    Filippi, F.; Mostacci, A.; Palumbo, L.; Anania, M.P.; Biagioni, A.; Chiadroni, E.; Ferrario, M.; Cianchi, A.; Zigler, A.

    2016-01-01

    Advanced particle accelerators are based on the excitation of large amplitude plasma waves driven by either electron or laser beams. Future experiments scheduled at the SPARC-LAB test facility aim to demonstrate the acceleration of high brightness electron beams through the so-called resonant Plasma Wakefield Acceleration scheme in which a train of electron bunches (drivers) resonantly excites wakefields into a preformed hydrogen plasma; the last bunch (witness) injected at the proper accelerating phase gains energy from the wake. The quality of the accelerated beam depends strongly on plasma density and its distribution along the acceleration length. The measurements of plasma density of the order of 10 16 –10 17  cm −3 can be performed with spectroscopic measurements of the plasma-emitted light. The measured density distribution for hydrogen filled capillary discharge with both Balmer alpha and Balmer beta lines and shot-to-shot variation are here reported.

  14. Spectroscopic measurements of plasma emission light for plasma-based acceleration experiments

    Science.gov (United States)

    Filippi, F.; Anania, M. P.; Biagioni, A.; Chiadroni, E.; Cianchi, A.; Ferrario, M.; Mostacci, A.; Palumbo, L.; Zigler, A.

    2016-09-01

    Advanced particle accelerators are based on the excitation of large amplitude plasma waves driven by either electron or laser beams. Future experiments scheduled at the SPARC_LAB test facility aim to demonstrate the acceleration of high brightness electron beams through the so-called resonant Plasma Wakefield Acceleration scheme in which a train of electron bunches (drivers) resonantly excites wakefields into a preformed hydrogen plasma; the last bunch (witness) injected at the proper accelerating phase gains energy from the wake. The quality of the accelerated beam depends strongly on plasma density and its distribution along the acceleration length. The measurements of plasma density of the order of 1016-1017 cm-3 can be performed with spectroscopic measurements of the plasma-emitted light. The measured density distribution for hydrogen filled capillary discharge with both Balmer alpha and Balmer beta lines and shot-to-shot variation are here reported.

  15. Influence of meal composition on postprandial peripheral plasma concentrations of vasoactive peptides in man

    DEFF Research Database (Denmark)

    Pedersen-Bjergaard, U; Høst, U; Kelbaek, H

    1996-01-01

    In a randomized cross-over study healthy non-obese male human subjects received standardized isocaloric, isovolumetric meals consisting of either carbohydrate, protein or fat and a non-caloric control meal consisting of an equal volume of water. Peripheral venous plasma concentrations of calcitonin...... that the postprandial peripheral plasma concentrations of CGRP, VIP and PYY are dependent on the caloric meal composition. The VIP, but not the CGRP and PYY concentrations seem to be influenced by gastric distension. The physiological significance of the postprandial alterations in peripheral concentrations...

  16. Comparison of Theory with Rotation Measurements in JET ICRH Plasmas

    International Nuclear Information System (INIS)

    R.V. Budny; C.S. Chang; C. Giroud; R.J. Goldston; D. McCune; J. Ongena; F.W. Perkins; R.B. White; K.-D. Zastrow; and contributors to the EFDA-JET work programme

    2001-01-01

    Plasma rotation appears to improve plasma performance by increasing the E x B flow shearing rate, thus decreasing radial correlations in the microturbulence. Also, plasma rotation can increase the stability to resistive MHD modes. In the Joint European Torus (JET), toroidal rotation rates omega (subscript ''tor'') with high Mach numbers are generally measured in NBI-heated plasmas (since the neutral beams aim in the co-plasma current direction). They are considerably lower with only ICRH (and Ohmic) heating, but still surprisingly large considering that ICRH appears to inject relatively small amounts of angular momentum. Either the applied torques are larger than naively expected, or the anomalous transport of angular momentum is smaller than expected. Since ICRH is one of the main candidates for heating next-step tokamaks, and for creating burning plasmas in future tokamak reactors, this paper attempts to understand ICRH-induced plasma rotation

  17. Fasting plasma total ghrelin concentrations in monozygotic twins discordant for obesity.

    Science.gov (United States)

    Leskelä, Piia; Ukkola, Olavi; Vartiainen, Johanna; Rönnemaa, Tapani; Kaprio, Jaakko; Bouchard, Claude; Kesäniemi, Y Antero

    2009-02-01

    Ghrelin is a hormone that is involved in the regulation of food intake. Neuronal, endocrine, and genetic factors have been shown to regulate plasma ghrelin levels; but the determinants of fasting ghrelin concentrations are not yet fully understood. The main aim was to explore the roles of adiposity and genetic differences in determining fasting plasma total ghrelin levels. We measured total ghrelin levels in a population of 23 monozygotic twin pairs discordant for obesity. In addition, 2 variants of ghrelin gene, namely, Arg51Gln and Leu72Met, were genotyped in 3 populations of monozygotic twin pairs: 23 obesity-discordant, 43 lean-concordant, and 46 obesity-concordant twin pairs. In discordant twins, lean co-twins had higher fasting plasma total ghrelin levels (950 pg/mL, SD = 328 pg/mL) than obese twins (720 pg/mL, SD = 143 pg/mL; P = .003). Arg51Gln-polymorphism of the ghrelin gene was equally distributed between the twin groups. However, there were significant differences in genotype frequencies at the Leu72Met polymorphism between the discordant and obese-concordant groups (P = .003) and between the discordant and lean-concordant groups (P = .011), but not between the 2 concordant groups. In the discordant group, there were fewer Met carriers (4%) than among the obese (17%) or the lean-concordant groups (15%). Plasma total ghrelin levels are affected by acquired obesity independent of genetic background. The Leu72 allele is particularly common among monozygotic twins discordant for obesity, suggesting that this ghrelin allele is more permissive in the regulation of energy balance. The ghrelin gene may thus play a role in the regulation of variability of body weight, such that Leu72 allele carriers are more prone to weight variability in response to environmental factors.

  18. Advances in deuterium dioxide concentration measurement

    Energy Technology Data Exchange (ETDEWEB)

    Shon, Woojung [University of Science & Technology, Daejeon (Korea, Republic of); Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yim, Sung Paal, E-mail: nspyim@kaeri.re.kr [University of Science & Technology, Daejeon (Korea, Republic of); Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Lim; Park, Hyunmin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Kwang Rag; Chung, Hongsuk [University of Science & Technology, Daejeon (Korea, Republic of); Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Cheo Kyung [Handong Global University, Pohang (Korea, Republic of)

    2016-11-01

    Highlights: • Heavy water (D{sub 2}O) with a high purity level is necessary for nuclear fusion application. • D{sub 2}O purity is analyzed using Fourier Transform infrared (FT-IR) spectroscopy and newly introduced off-axis integrated cavity output spectroscopy (OA-ICOS). • OA-ICOS has advantages in terms of analysis of D{sub 2}O vapor. • OA-ICOS is expected that it can be used for accurate isotopic analyses in the future. - Abstract: The deuterium–tritium (D–T) reaction has been identified as the most efficient reaction for fusion devices. Deuterium can be obtained by heavy water electrolysis. Heavy water (D{sub 2}O) with a high purity level is necessary for nuclear fusion application. A D{sub 2}O isotopic analysis is thus very important. A system for a heavy water analysis was built and a newly designed isotopic analysis experiment was carried out. We tried to analyze the D{sub 2}O purity using Fourier Transform infrared (FT-IR) spectroscopy and newly introduced off-axis integrated cavity output spectroscopy (OA-ICOS). We found that the OA-ICOS based on measurement via laser absorption spectroscopy shows very high sensitivity. We ameliorated the sensitivity by an order of magnitude of more than 10{sup 3}–10{sup 5}. We could make the apparatus smaller by employing very tiny diode laser and fiber optics elements of a DFB (Distributed Feedback) type. Consequently, our device has advantages in terms of maintainability and mobility even in a radioactive environment. This new method could be used for an accurate isotopic analysis in the future.

  19. Concentrations of plasma copper and zinc and blood selenium in ...

    African Journals Online (AJOL)

    prior to lambing, when they were transferred to kikuyu pastures. From six weeks prior to lambing, all the ewes received 0,5 kg supplementary feeding daily. This was increased by 0,1 kg per week up to lambing. The diet consisted of 55% oaten hay, 35,6% barley, 4% fish meal, 3% Rumevite stud concentrate,. 1% bentonite,.

  20. Platelet concentration of plateletrich plasma from dogs, obtained through three centrifugation speeds

    Directory of Open Access Journals (Sweden)

    Vanessa Couto de Magalhães Ferraz

    2007-12-01

    Full Text Available The platelets release at least 4 growth factors (Platelet Derived Growth Factor. ²1 and ²2 Transforming Growth Factors and Insulin-like Growth Factor which are responsible for the migration and activation of cells that will start the reparation of soft tissues and bones. The Platelet Rich Plasma is an autogenous source for Growth Factors, obtained by platelet concentration by centrifuging total blood. This study aimed the comparison of platelet concentrations in plasma centrifuged in three different centrifugation speeds (1300, 1600 e 3200rpm, for the production of platelet rich plasma. Blood was drowned from 15 dogs, 40ml of each, and these were divided into four groups and centrifuged at 800rpm. Then the first group was centrifuged at 1300rpm, the second at 1600rpm, the third at 3200rpm and the last was used as control, named plasma. The mean percentage increase in the platelet concentration for each technique was: 1300 - 183%, 1600 - 210% and 3200 - 222%. But in centrifugation at 3200 rpm, platelets presented altered morphology and different sizes in every sample studied, which was understood as severe cell damage. It was concluded that the best technique for the preparation of the platelet rich plasma in dogs consisted of the previous centrifugation of the blood at 800rpm for ten minutes, and then the plasma should be separated. This plasma is then submitted to a second centrifugation of 1600rpm for 10 minutes, and the platelet poor plasma is separated and discharged.

  1. Plasma phospholipid fatty acid concentration and incident coronary heart disease in men and women: the EPIC-Norfolk prospective study.

    Directory of Open Access Journals (Sweden)

    Kay-Tee Khaw

    Full Text Available The lack of association found in several cohort studies between dietary saturated fat and coronary heart disease (CHD risk has renewed debate over the link between dietary fats and CHD.We assessed the relationship between plasma phospholipid fatty acid (PFA concentration and incident CHD using a nested case control design within a prospective study (EPIC-Norfolk of 25,639 individuals aged 40-79 years examined in 1993-1997 and followed up to 2009. Plasma PFA concentrations were measured by gas chromatography in baseline samples retrieved from frozen storage. In 2,424 men and women with incident CHD compared with 4,930 controls alive and free of cardiovascular disease, mean follow-up 13 years, saturated PFA (14:0, 16:0,18:0 plasma concentrations were significantly associated with increased CHD risk (odds ratio [OR] 1.75, 95% CI 1.27-2.41, p<0.0001, in top compared to bottom quartiles (Q, and omega-6 polyunsaturated PFA concentrations were inversely related (OR 0.77, 0.60-0.99, p<0.05 after adjusting for age, sex, body mass index, blood pressure, smoking, alcohol intake, plasma vitamin C, social class, education, and other PFAs. Monounsaturated PFA, omega-3 PFA, and trans PFA concentrations were not significantly associated with CHD. Odd chain PFA (15:0, 17:0 concentrations were significantly inversely associated with CHD (OR 0.73, 0.59-0.91, p<0.001, Q4 versus Q1. Within families of saturated PFA or polyunsaturated PFA, significantly heterogeneous relationships with CHD were observed for individual fatty acids.In this study, plasma concentrations of even chain saturated PFA were found to be positively and omega-6 polyunsaturated PFA inversely related to subsequent coronary heart disease risk. These findings are consistent with accumulating evidence suggesting a protective role of omega-6 fats substituting for saturated fats for CHD prevention.

  2. Interferometer for electron density measurement in exploding wire plasma

    International Nuclear Information System (INIS)

    Batra, Jigyasa; Jaiswar, Ashutosh; Kaushik, T.C.

    2016-12-01

    Mach-Zehnder Interferometer (MZI) has been developed for measuring electron density profile in pulsed plasmas. MZI is to be used for characterizing exploding wire plasmas for correlating electron density dynamics with x-rays emission. Experiments have been carried out for probing electron density in pulsed plasmas produced in our laboratory like in spark gap and exploding wire plasmas. These are microsecond phenomenon. Changes in electron density have been registered in interferograms with the help of a streak camera for specific time window. Temporal electron density profiles have been calculated by analyzing temporal fringe shifts in interferograms. This report deals with details of MZI developed in our laboratory along with its theory. Basic introductory details have also been provided for exploding wire plasmas to be probed. Some demonstrative results of electron density measurements in pulsed plasmas of spark gap and single exploding wires have been described. (author)

  3. Influence of antihypertensive therapy, sodium intake and the concentration of potassium in plasma on concentration of aldosterone and plasma renin activity

    Directory of Open Access Journals (Sweden)

    Lalić Tijana

    2013-01-01

    Full Text Available Introduction: Primary aldosteronism (PA is a group of disorders which are characterized by inadequate and non-suppressible production of aldosterone. The prevalence of PA is increasing in hypertensive population. The golden standard of screening for primary aldosteronism, determination of aldosterone/plasma renin activity (ARR, is influenced by numerous exogenous and endogenous factors. Testing cannot always be conducted under optimal conditions. Objective: To determine influence of antihypertensive drugs and concentrations of potassium and sodium in blood and urine on values of aldosterone and plasma renin activity. Methods: In this retrospective study, we analyzed medical reports of patients admitted to Department of thyroid gland disease in the period from 2009 to 2011, with increased risk for primary aldosteronism. Body weight and height, sodium and potassium in serum and urine, plasma aldosterone concentrations and plasma renin activity, data on medicines and comorbidity were analyzed in all patients. In processing data, statistical methods descriptive analysis, Student T test and univariate linear regression were applied. Result: Of 137 patients, there were more patients with resistant hypertension (53,28% than with adrenal tumors (46,72%. Most patients used calcium channel blockers. Treatment with alpha blockers and calcium channel blockers does not influence ARR. Beta blockers and ACE inhibitors can influence ARR and diuretics and vasodilatators have definite influence. Diabetes mellitus can have higher risk of false negative results. Urine sodium excretion is significantly correlated with plasma aldosteron and serum potassium. Plasma aldosteron and PRA are significantly correlated with concentrations of electrolites in urine. Conclusion: Increased prevalence of primary aldosteronism necessitates need for accurate and better diagnostics.

  4. Plasma turbulence measured by fast sweep reflectometry on Tore Supra

    International Nuclear Information System (INIS)

    Clairet, F.; Vermare, L.; Leclert, G.

    2004-01-01

    Traditionally devoted to electron density profile measurement we show that fast frequency sweeping reflectometry technique can bring valuable and innovative measurements onto plasma turbulence. While fast frequency sweeping technique is traditionally devoted to electron density radial profile measurements we show in this paper how we can handle the fluctuations of the reflected signal to recover plasma density fluctuation measurements with a high spatial and temporal resolution. Large size turbulence related to magneto-hydrodynamic (MHD) activity and the associated magnetic islands can be detected. The radial profile of the micro-turbulence, which is responsible for plasma anomalous transport processes, is experimentally determined through the fluctuation of the reflected phase signal. (authors)

  5. Plasma turbulence measured by fast sweep reflectometry on Tore Supra

    International Nuclear Information System (INIS)

    Clairet, F.; Vermare, L.; Heuraux, S.; Leclert, G.

    2004-01-01

    Traditionally devoted to electron density profile measurement we show that fast frequency sweeping reflectometry technique can bring valuable and innovative measurements onto plasma turbulence. While fast frequency sweeping technique is traditionally devoted to electron density radial profile measurements we show in this paper how we can handle the fluctuations of the reflected signal to recover plasma density fluctuation measurements with a high spatial and temporal resolution. Large size turbulence related to magneto-hydrodynamic (MHD) activity and the associated magnetic islands can be detected. The radial profile of the micro-turbulence, which is responsible for plasma anomalous transport processes, is experimentally determined through the fluctuation of the reflected phase signal

  6. Measurement of plasma flows into tile gaps

    Czech Academy of Sciences Publication Activity Database

    Dejarnac, Renaud; Komm, Michael; Stöckel, Jan; Pánek, Radomír

    2008-01-01

    Roč. 382, č. 1 (2008), s. 31-34 ISSN 0022-3115 R&D Projects: GA AV ČR KJB100430602 Institutional research plan: CEZ:AV0Z20430508 Keywords : Tokamak diagnostic * Gaps * Ion saturation current * Edge modeling * Sheaths Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.501, year: 2008

  7. Retinol, carotenoids, and tocopherols in the milk of lactating adolescents and relationships with plasma concentrations.

    Science.gov (United States)

    de Azeredo, Vilma B; Trugo, Nadia M F

    2008-02-01

    We determined the concentrations of retinol, carotenoids, and tocopherols in breast milk of adolescents and evaluated their associations with plasma levels and with maternal characteristics (period of lactation, body mass index, age of menarche, and years postmenarche). This was a single cross-sectional survey of retinol, carotenoid, and tocopherol composition of milk and plasma of lactating adolescent mothers (n = 72; 30-120 d postpartum) attending public daycare clinics in Rio de Janeiro, Brazil. Milk and plasma components were analyzed by high-performance liquid chromatography. Nutrient concentrations (micromoles per liter, mean +/- SE) in plasma and milk were, respectively, retinol 2.1 +/- 0.5 and 0.62 +/- 0.44, beta-carotene 0.18 +/- 0.19 and 0.016 +/- 0.017, alpha-carotene 0.05 +/- 0.04 and 0.0035 +/- 0.002, lutein plus zeaxanthin 0.15 +/- 0.11 and 0.025 +/- 0.024, lycopene 0.1 +/- 0.11 and 0.016 +/- 0.025, alpha-tocopherol 10.8 +/- 5.3 and 2.7 +/- 1.8, gamma-tocopherol 2.6 +/- 2.3 and 0.37 +/- 0.15. The milk/plasma molar ratios of retinol and tocopherols were two times higher than those of carotenoids. Significant correlations (P milk and plasma nutrient levels were observed for beta-carotene (r = 0.41), alpha-carotene (r = 0.60), and lutein plus zeaxanthin (r = 0.57), but not for lycopene, retinol, and tocopherols. Nutrient concentrations in plasma and in milk were not associated with the maternal characteristics investigated. Concentrations of the nutrients studied, especially retinol and alpha-tocopherol, in mature milk of lactating adolescents were, in general, lower than in milk of adult lactating women. Milk concentrations were associated with plasma concentrations only for beta-carotene, alpha-carotene, and lutein plus zeaxanthin.

  8. Semen quality and concentration of soluble proteins in the seminal plasma of Alpine bucks Semen quality and concentration of soluble proteins in the seminal plasma of Alpine bucks

    Directory of Open Access Journals (Sweden)

    Simone Eliza Facione Guimarães

    2010-06-01

    Full Text Available It was aimed to study the in vitro seminal quality analyzed by complementary tests and to compare them with physical, morphological and biochemical aspects of male goat semen of the Alpine breed. This experiment took place at the Federal University of Viçosa, situated at 20º45’ S latitude and 42º51’ W longitude, Southwest of Brazil. It was done during the summer months of January and February, and three adult male goats of the Alpine breed were used in intensive conditions. The semen was collected by artificial vagina method. In all semen samples (45 ejaculates, after the physical and morphological analysis, the hiposmotic test was done. In 24 ejaculates, it were done thermo-resistance test, and in 21 ejaculates it were determined the concentration of total soluble proteins in seminal plasma. The male goats presented difference in the semen physical and morphological aspects, in the hiposmotic test and thermo-resistance test, but they did not presented difference in total soluble proteins concentration in seminal plasma. Results of the slow thermo-resistance test and hiposmotic test were positively correlated (r = 0.60. It was concluded, according to our results, that the concentration of total soluble proteins in seminal plasma can not be used as a parameter to predict the seminal quality of Alpine bucks.It was aimed to study the in vitro seminal quality analyzed by complementary tests and to compare them with physical, morphological and biochemical aspects of male goat semen of the Alpine breed. This experiment took place at the Federal University of Viçosa, situated at 20º45’ S latitude and 42º51’ W longitude, Southwest of Brazil. It was done during the summer months of January and February, and three adult male goats of the Alpine breed were used in intensive conditions. The semen was collected by artificial vagina method. In all semen samples (45 ejaculates, after the physical and morphological analysis, the hiposmotic test

  9. Temperature measurement in low pressure plasmas. Temperaturmessungen im Niederdruckplasma

    Energy Technology Data Exchange (ETDEWEB)

    Rosenbauer, K.A.; Wilting, H.; Schramm, G. (Duesseldorf Univ. (Germany, F.R.). Abt. fuer Histologie und Embryologie)

    1989-11-01

    The present work discusses the influence of various parameters on the substrate temperature in a low pressure plasma. The measurement method chosen utilized Signotherm (Merck) temperature sensors embedded in silicon between two glass substrates. All measurements were made in a 200 G Plasma Processor from Technics Plasma GmbH. The substrate temperature is dependent on the process time, the RF power, the process gas and the position in the chamber. The substrate temperature increases with increasing process time and increasing power. Due to the location of the microwave port from the magnetron to the chamber, the substrate temperature is highest in the center of the chamber. Measurements performed in an air plasma yielded higher results than in an oxygen plasma. (orig.).

  10. Measurement of effective renal plasma flow in congestive heart failure

    International Nuclear Information System (INIS)

    Tauxe, W.N.; Dubovsky, E.V.; Mantle, J.A.; Dustan, H.P.; Logic, J.R.

    1981-01-01

    In the management of patients with congestive heart failure (CHF), it is often desirable to have precise knowledge of overall renal function, including the effective renal plasma flow (ERPF). It has long been recognized that ERPF is diminished in CHF. Since glomerular filtration rate is often decreased to a much lesser extent, other noninvasive procedures such as the measurement of creatinine clearances may not be entirely suitable. ERPF determination by the single plasma sampling (SPS) method affords a rapid, simple, noninvasive, and economical technique that is quite accurate and reproducible. A SPS method has been well-tested in patients following renal transplantation plus a wide variety of nephrological disorders. We have been concerned whether the SPS method would be valid in volume expanded patients. In 28 determinations of ERPF in patients with CHF, and in five patients who did not have CHF, we have found the SPS estimation of ERPF to yield results that are not clinically significantly different from those obtained by the detailed compartmental analysis method. The volumes of 131 I-orthoiodohippurate (OIH) distribution were found to be somewhat higher in CHF than in controls, but fractional rate constants were proportionately lower so that intercompartmental flow rates and OIH concentrations were not different from controls. Therefore, the SPS estimation of ERPF is valid in patients with CHF and may be useful in monitoring the renal effects of various hemodynamic and pharmacological interventions. (orig.)

  11. Plasma concentrations of free triiodothyronine predict weight change in euthyroid persons2

    Science.gov (United States)

    Ortega, Emilio; Pannacciulli, Nicola; Bogardus, Clifton; Krakoff, Jonathan

    2007-01-01

    Background Factors that influence energy metabolism and substrate oxidation, such as thyroid hormones (THs), may be important regulators of body weight. Objective We investigated associations of THs cross-sectionally with obesity, energy expenditure, and substrate oxidation and prospectively with weight change. Design Euthyroid, nondiabetic, healthy, adult Pima Indians (n = 89; 47 M, 42 F) were studied. Percentage body fat (%BF) was measured by using dual-energy X-ray absorptiometry; sleeping metabolic rate (SMR), respiratory quotient, and substrate oxidation rates were measured in a respiratory chamber. Thyroid-stimulating hormone (TSH), free thyroxine (T4), free triiodothyronine (T3), and leptin concentrations were measured in fasting plasma samples. Results TSH, but neither free T3 nor free T4, was associated with %BF and leptin concentrations (r = 0.27 and 0.29, respectively; both: P ≤ 0.01). In multiple regression analyses adjusted for age, sex, fat mass, and fat-free mass, free T3 was a positive predictor of SMR (P = 0.02). After adjustment for age, sex, %BF, and energy balance, free T3 was a negative predictor of 24-h respiratory quotient (P < 0.05) and a positive predictor of 24-h lipid oxidation rate (P = 0.006). Prospectively, after an average follow-up of 4 ± 2 y, the mean increase in weight was 3 ± 9 kg. Baseline T3 concentrations were associated with absolute and annual percentage of changes in weight (r = −0.27, P = 0.02, and r = −0.28, P = 0.009, for the age-and sex-adjusted associations, respectively). Conclusions In euthyroid Pima Indians, lower free T3 but not free T4 concentrations were an independent predictor of SMR and lipid oxidation and a predictor of weight gain. This finding indicates that control of T4-to-T3 conversion may play a role in body weight regulation. PMID:17284741

  12. Methods for direct measurement of the plasma potential

    DEFF Research Database (Denmark)

    Andersen, S. A.; Christoffersen, G. B.; Jensen, Vagn Orla

    1972-01-01

    Reports on a simple experimental technique which can be used for determination of the plasma where the plasma potential prevails; these ions are accepted by the analyser plate when phi c= phi pl. Part of this technique has been used by Andersen, Jensen, Michelsen and Nielsen (1971) in measurements...

  13. Measurements of plasma temperature and electron density in laser

    Indian Academy of Sciences (India)

    The temperature and electron density characterizing the plasma are measured by time-resolved spectroscopy of neutral atom and ion line emissions in the time window of 300–2000 ns. An echelle spectrograph coupled with a gated intensified charge coupled detector is used to record the plasma emissions.

  14. High-nitrate vegetable diet increases plasma nitrate and nitrite concentrations and reduces blood pressure in healthy women.

    Science.gov (United States)

    Ashworth, Ann; Mitchell, Klaus; Blackwell, Jamie R; Vanhatalo, Anni; Jones, Andrew M

    2015-10-01

    Epidemiological studies suggest that green leafy vegetables, which are high in dietary nitrate, are protective against CVD such as stroke. High blood pressure (BP) is a major risk factor for stroke and inorganic nitrate has been shown to reduce BP. The objective of the present study was to test the hypothesis that diets containing high-nitrate (HN) vegetables would increase plasma nitrate and nitrite concentrations and reduce BP in healthy women. A randomized, crossover trial, where participants received HN vegetables (HN diet) or avoided HN vegetables (Control diet) for 1 week. Before and after each intervention, resting BP and plasma nitrate and nitrite concentrations were measured. University of Exeter, UK. Nineteen healthy women (mean age 20 (sd 2) years; mean BMI 22·5 (sd 3·8) kg/m2). The HN diet significantly increased plasma nitrate concentration (before HN diet: mean 24·4 (sd 5·6) µmol/l; after HN diet: mean 61·0 (sd 44·1) µmol/l, Pdiet: mean 98 (sd 91) nmol/l; after HN diet: mean 185 (sd 34) nmol/l, Pdiet. The HN diet significantly reduced resting systolic BP (before HN diet: mean 107 (sd 9) mmHg; after HN diet: mean 103 (sd 6) mmHg, Pdiet (before Control diet: mean 106 (sd 8) mmHg; after Control diet: mean 106 (sd 8) mmHg). Consumption of HN vegetables significantly increased plasma nitrate and nitrite concentrations and reduced BP in normotensive women.

  15. Plasma heme oxygenase-1 concentration is elevated in individuals with type 2 diabetes mellitus.

    Directory of Open Access Journals (Sweden)

    Wei Bao

    Full Text Available BACKGROUND: Circulating concentrations of heme oxygenase-1 (HO-1 have been recently reported to be elevated in several chronic disorders. However, no study has ever examined the association between circulating HO-1 concentrations and type 2 diabetes mellitus (T2DM. METHODS AND FINDINGS: 581 cases with newly-diagnosed T2DM (New-T2DM and 611 comparison controls were recruited in this two-phase case-control study, comprising 420 cases and 429 controls collected in the first phase study and 161 cases and 182 controls in the second phase replication study. Analyses, using both separated data and combined data from the two-phase studies, show that plasma HO-1 concentrations were significantly increased in New-T2DM cases compared to controls (P<0.001. Plasma HO-1 concentrations were significantly correlated with plasma glucose concentrations, HOMA-beta and HOMA-IR (P<0.001. After adjustment for age, sex, BMI and family history of diabetes, the ORs for New-T2DM in the highest quartile of plasma HO-1 concentrations, compared with the lowest, was 8.23 (95% CI 5.55-12.21; P for trend <0.001. The trend remained significant after additional adjustment for fasting plasma glucose/insulin, HOMA-beta/HOMA-IR, TC/TG, smoking, drinking and history of hypertension, and even in further stratification analysis by age, sex, BMI, smoking, drinking and history of hypertension. CONCLUSIONS: Elevated plasma HO-1 concentrations are associated with higher ORs for New-T2DM, which add more knowledge regarding the important role of oxidative stress in T2DM. More consequent studies were warranted to confirm the clinical utility of plasma HO-1, especially in diagnosis and prognosis of T2DM and its complications.

  16. Effect of low-fat diets on plasma high-density lipoprotein concentrations

    NARCIS (Netherlands)

    Katan, M.B.

    1998-01-01

    Low concentrations of HDLs in plasma are a strong predictor of risk for coronary as well as other cardiovascular diseases. There is increasing evidence that this relation is causal and that interventions that change HDL concentrations also change risk. One such intervention is exchanging fat and

  17. Concentration of vanadium in crude oil and water using inductively-coupled plasma spectrometry

    International Nuclear Information System (INIS)

    Amin, Y.M.; Hassan, M.A.; Junkin, K.; Mahat, R.H.; Raphie, B.

    1991-01-01

    Vanadium is a trace element that is usually associated to crude oil and its products. In this study the concentration of vanadium in a few samples of local crude oil, sea and river water were determined using inductively-coupled plasma spectrometry (ICP). It is hoped that the concentration of vanadium in water can be used to indicate the possible extent of oil contamination

  18. PFAS concentrations in plasma samples from Danish school children and their mothers.

    Science.gov (United States)

    Mørck, Thit A; Nielsen, Flemming; Nielsen, Jeanette K S; Siersma, Volkert D; Grandjean, Philippe; Knudsen, Lisbeth E

    2015-06-01

    Perfluoroalkyl substances (PFASs) are accumulating in our environment and human exposure to these potentially harmful chemicals are of growing concern. In the present study, 116 children aged 6-11 and 143 mothers in two locations in Denmark donated blood samples as a supplement to their participation in the large European human biomonitoring project, DEMOCOPHES (Demonstration of a study to COordinate and Perform Human Biomonitoring on a European Scale). The blood samples were analyzed by LC-MS/MS for the concentration of six PFASs: PFOA, PFHxS, PFNA, PFDA, br-PFOS and n-PFOS. All measured compounds were above the detection limit in both mothers and children except for PFHxS in one child. There was a significant correlation between the levels in children and their mothers, indicating a family-related exposure pattern. However, we also found that the levels of PFOA, PFNA, PFDA, br-PFOS and total-PFOS were significantly higher in children compared to their mothers. This may be due to higher exposure in children through for example dust and soil, and due to the fact that children are smaller in body size and blood volume and hence have a lower storage capacity. Furthermore, we found an association between plasma levels and the age of the mothers and higher levels of plasma PFASs in mothers with low parity. There were no associations between PFAS concentrations and residential area, dietary habits of the participants or with respect to the birth order of the children. The levels are comparable to concentrations found in other Western countries. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Measuring the equations of state in a relaxed magnetohydrodynamic plasma

    Science.gov (United States)

    Kaur, M.; Barbano, L. J.; Suen-Lewis, E. M.; Shrock, J. E.; Light, A. D.; Brown, M. R.; Schaffner, D. A.

    2018-01-01

    We report measurements of the equations of state of a fully relaxed magnetohydrodynamic (MHD) laboratory plasma. Parcels of magnetized plasma, called Taylor states, are formed in a coaxial magnetized plasma gun, and are allowed to relax and drift into a closed flux conserving volume. Density, ion temperature, and magnetic field are measured as a function of time as the Taylor states compress and heat. The theoretically predicted MHD and double adiabatic equations of state are compared to experimental measurements. We find that the MHD equation of state is inconsistent with our data.

  20. Inflammatory markers in dependence on the plasma concentration of 37 fatty acids after the coronary stent implantation.

    Science.gov (United States)

    Handl, Jiří; Meloun, Milan; Mužáková, Vladimíra

    2018-02-05

    Using the regression model building the relationships between the concentration of 37 fatty acids of blood plasma phospholipids of 41 patients with coronary artery disease after coronary stent implantation, the inflammatory response and oxidative stress markers were estimated. The dynamics of the inflammatory response and the oxidative stress was indicated by measuring plasma concentrations of highly sensitive C-reactive protein, interleukin-6, serum amyloid A and malondialdehyde before, 24h after stent implantation. The multiple linear regression analysis was preceded by an exploratory data analysis, principal component analysis, factor analysis and cluster analysis, which proved a hidden internal relation of 37 fatty acids. The concentration of cerotic acid (C26:0) has been positively associated with an increase of malondialdehyde concentration after stent implantation, while the concentrations of tetracosatetraenoic (C24:4 N6) and nonadecanoic (C19:0) acids were associated with decrease of lipoperoxidation. The increase of interleukin-6 during the 24h after implantation was associated with higher levels of pentadecanoic acid (C15:0) and lower levels of α-linolenic acid (C18:3 N3). Regression models found several significant fatty acids at which the strength of the parameter β for each fatty acid on selected markers of C-reactive protein, malondialdehyde, interleukin-6 and serum amyloid A was estimated. Parameter β testifies to the power of the positive or negative relationship of the fatty acid concentration on the concentration of selected markers. The influencing effect of the cerotic acid (C26:0) concentration in plasma phospholipids exhibiting parameter β=140.4 is, for example, 3.5 times higher than this effect of n-3 tetracosapentaenoic acid (C24:5 N3) with β=40.0. Composition of fatty acids in plasma phospholipids shows spectrum of fatty acids available for intercellular communication in systemic inflammatory response of organism and should affect

  1. Plasma corticosterone and thyroxine concentrations during chronic ingestion of crude oil in mallard ducks (Anas platyrhynchos)

    Science.gov (United States)

    Rattner, B.A.; Eastin, W.C.

    1981-01-01

    1. Blood samples were collected from mallard ducks after 6, 12, and 18 weeks of dietary exposure to mash containing 0.015%, 0.150%, and 1.500% crude oil.2. Plasma corticosterone concentrations in ducks fed mash containing 0.150% or 1.500% Alaskan Prudhoe Bay crude oil were uniformly depressed when compared to values in untreated control birds.3. Plasma thyroxine concentration was not altered in ducks chronically exposed to crude oil.4. The observed alteration in corticosterone concentration could reduce tolerance to temperature and dietary fluctuations in the environment.

  2. Rhabdomyolysis and Artifactual Increase in Plasma Bicarbonate Concentration in an Amazon Parrot (Amazona species).

    Science.gov (United States)

    Leissinger, Mary K; Johnson, James G; Tully, Thomas N; Gaunt, Stephen D

    2017-09-01

    A 7-year-old male Amazon parrot housed outdoors presented with acute collapse, marked lethargy, and open-mouth breathing. The patient had stiffness of the pectoral muscles, and petechiation and ecchymosis noted around the eyes and beneath the mandible. Laboratory data revealed markedly increased aspartate aminotransferase, creatine kinase, and lactate dehydrogenase activity consistent with rhabdomyolysis, as well as markedly increased plasma bicarbonate concentration. Marked clinical improvement and resolution of laboratory abnormalities occurred with fluid therapy, administration of a nonsteroidal anti-inflammatory medication, and husbandry modifications, including indoor housing and dietary alteration. A spurious increase in bicarbonate measurement as documented in equine and bovine cases of rhabdomyolysis also occurred in this avian patient and must be considered for accurate interpretation of acid-base status in exotic species presenting with consistent clinical signs.

  3. Changes in relative and absolute concentrations of plasma phospholipid fatty acids observed in a randomized trial of Omega-3 fatty acids supplementation in Uganda.

    Science.gov (United States)

    Song, Xiaoling; Diep, Pho; Schenk, Jeannette M; Casper, Corey; Orem, Jackson; Makhoul, Zeina; Lampe, Johanna W; Neuhouser, Marian L

    2016-11-01

    Expressing circulating phospholipid fatty acids (PLFAs) in relative concentrations has some limitations: the total of all fatty acids are summed to 100%; therefore, the values of individual fatty acid are not independent. In this study we examined if both relative and absolute metrics could effectively measure changes in circulating PLFA concentrations in an intervention trial. 66 HIV and HHV8 infected patients in Uganda were randomized to take 3g/d of either long-chain omega-3 fatty acids (1856mg EPA and 1232mg DHA) or high-oleic safflower oil in a 12-week double-blind trial. Plasma samples were collected at baseline and end of trial. Relative weight percentage and absolute concentrations of 41 plasma PLFAs were measured using gas chromatography. Total cholesterol was also measured. Intervention-effect changes in concentrations were calculated as differences between end of 12-week trial and baseline. Pearson correlations of relative and absolute concentration changes in individual PLFAs were high (>0.6) for 37 of the 41 PLFAs analyzed. In the intervention arm, 17 PLFAs changed significantly in relative concentration and 16 in absolute concentration, 15 of which were identical. Absolute concentration of total PLFAs decreased 95.1mg/L (95% CI: 26.0, 164.2; P=0.0085), but total cholesterol did not change significantly in the intervention arm. No significant change was observed in any of the measurements in the placebo arm. Both relative weight percentage and absolute concentrations could effectively measure changes in plasma PLFA concentrations. EPA and DHA supplementation changes the concentrations of multiple plasma PLFAs besides EPA and DHA.Both relative weight percentage and absolute concentrations could effectively measure changes in plasma phospholipid fatty acid (PLFA) concentrations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Correlation between lamivudine plasma concentrations and patient self-reported adherence to antiretroviral treatment in experienced HIV patients

    Directory of Open Access Journals (Sweden)

    Minzi OM

    2011-11-01

    Full Text Available OM Minzi1, V Mugoyela2, LL Gustafsson31Unit of Pharmacology and Therapeutics, 2Department of Medicinal Chemistry, School of Pharmacy, Muhimbili University of Health and Allied Sciences, Dar Es Salaam, Tanzania; 3Division of Clinical Pharmacology, Department of Laboratory Medicine, Karolinska Institutet, Karolinska University Hospital, Huddinge, Stockholm, SwedenBackground: Adherence to antiretroviral treatment (ART is important to achieve treatment success in human immunodeficiency virus (HIV-infected patients. Most HIV clinics apply the patient self-report (PSR method. However, the reliability of this method in experienced HIV patients remains questionable.Purpose: To validate the PSR method for measuring adherence to ART using lamivudine (3TC plasma concentrations in experienced HIV patients.Methods: The study was conducted in Dar Es Salaam and involved 220 patients who were receiving ART services at HIV clinics for more than 12 months. Self-reported adherence information to ART was obtained on the day of HIV clinic visit. The patients were asked to mention the number of doses missed within the past 7 days. In addition, blood samples (2 mL were collected from each patient on the same day. The blood samples were determined for 3TC plasma concentrations. The target 3TC plasma concentration as indicator concentration for adherent patients was determined in 20 patients who took their evening dose of antiretrovirals under supervision. The blood from these patients was drawn 3 hours after drug administration.Results: Complete drug levels of 3TC and self-reported adherence data was obtained in 200 treatment-experienced HIV patients. Lamivudine plasma concentrations obtained in these patients ranged between 0.02–17.36 µg/mL. The mean time from dose administration to blood drawing was 3.1 ± 1.2 hours with coefficient of variation >39%. The mean 3TC plasma concentration obtained in 20 patients who took their antiretroviral dose under supervision was

  5. Flavonoid-rich dark chocolate improves endothelial function and increases plasma epicatechin concentrations in healthy adults.

    Science.gov (United States)

    Engler, Mary B; Engler, Marguerite M; Chen, Chung Y; Malloy, Mary J; Browne, Amanda; Chiu, Elisa Y; Kwak, Ho-Kyung; Milbury, Paul; Paul, Steven M; Blumberg, Jeffrey; Mietus-Snyder, Michele L

    2004-06-01

    Dark chocolate derived from the plant (Theobroma cacao) is a rich source of flavonoids. Cardioprotective effects including antioxidant properties, inhibition of platelet activity, and activation of endothelial nitric oxide synthase have been ascribed to the cocoa flavonoids. To investigate the effects of flavonoid-rich dark chocolate on endothelial function, measures of oxidative stress, blood lipids, and blood pressure in healthy adult subjects. The study was a randomized, double-blind, placebo-controlled design conducted over a 2 week period in 21 healthy adult subjects. Subjects were randomly assigned to daily intake of high-flavonoid (213 mg procyanidins, 46 mg epicatechin) or low-flavonoid dark chocolate bars (46 g, 1.6 oz). High-flavonoid chocolate consumption improved endothelium-dependent flow-mediated dilation (FMD) of the brachial artery (mean change = 1.3 +/- 0.7%) as compared to low-flavonoid chocolate consumption (mean change = -0.96 +/- 0.5%) (p = 0.024). No significant differences were noted in the resistance to LDL oxidation, total antioxidant capacity, 8-isoprostanes, blood pressure, lipid parameters, body weight or body mass index (BMI) between the two groups. Plasma epicatechin concentrations were markedly increased at 2 weeks in the high-flavonoid group (204.4 +/- 18.5 nmol/L, p < or = 0.001) but not in the low-flavonoid group (17.5 +/- 9 nmol/L, p = 0.99). Flavonoid-rich dark chocolate improves endothelial function and is associated with an increase in plasma epicatechin concentrations in healthy adults. No changes in oxidative stress measures, lipid profiles, blood pressure, body weight or BMI were seen.

  6. Effect of 'PC Game Room' use and polycyclic aromatic hydrocarbon exposure on plasma testosterone concentrations in young male Koreans.

    Science.gov (United States)

    Kim, Heon; Kang, Jong-Won; Ku, Seung-Yup; Kim, Seok Hyun; Cho, Soo-Hun; Koong, Sung-Soo; Kim, Yong-Dae; Lee, Chul-Ho

    2005-03-01

    'PC Game Rooms' were first popularized in Korea, although the concept is now becoming popular worldwide. PC Game Rooms provide users with high-performance PC connected to the high-speed internet, and access to computer games. However, PC Game Room users are exposed to various hazardous agents such as cigarette smoke in a confined environment, and thus it is likely that excessive PC Game Room use involves abnormal exposure to polycyclic aromatic hydrocarbons (PAH) as well as being associated with disturbed sleep or circadian rhythm. In this cross-sectional study, the exposure to PAH was evaluated by measuring urinary 1-hydroxypyrene (1-OHP) and 2-naphthol. The correlations between PC Game Room use and PAH exposure and plasma testosterone and LH levels were analysed in 208 young male Koreans. Urinary 1-OHP concentrations increased (P = 0.0001) and plasma testosterone levels decreased (P = 0.0153) significantly with increased duration of PC Game Room use. Correlation analysis showed that plasma testosterone concentrations were significantly negatively correlated with urinary 1-OHP (r = -0.22, P = 0.0012) and 2-naphthol (r = -0.15, P = 0.0308) concentrations. Moreover, these associations persisted after adjusting for other independent variables. However, the duration of PC Game Room use itself was not found to be an independent significant determinant of plasma testosterone level. Rather, PC Game Room use increased PAH exposure, which decreased plasma testosterone level. The younger age group (15-19 years) showed a more prominent decrease in plasma testosterone concentrations with increasing duration of PC Game Room use than the older age group (20-24 years) (r2 = 0.355, P = 0.0301 versus r2 = 0.213, P = 0.0001). These results imply that the excessive use of PC Game Rooms is related to an adverse impact on sex hormonal status in young male Koreans via PAH exposure. This effect was more prominent in the younger age group.

  7. Increased plasma proline concentrations are associated with sarcopenia in the elderly.

    Science.gov (United States)

    Toyoshima, Kenji; Nakamura, Marie; Adachi, Yusuke; Imaizumi, Akira; Hakamada, Tomomi; Abe, Yasuko; Kaneko, Eiji; Takahashi, Soiciro; Shimokado, Kentaro

    2017-01-01

    Metabolome analyses have shown that plasma amino acid profiles reflect various pathological conditions, such as cancer and diabetes mellitus. It remains unclear, however, whether plasma amino acid profiles change in patients with sarcopenia. This study therefore aimed to investigate whether sarcopenia-specific changes occur in plasma amino acid profiles. A total of 153 community-dwelling and seven institutionalized elderly individuals (56 men, 104 women; mean age, 77.7±7.0 years) were recruited for this cross-sectional analysis. We performed a comprehensive geriatric assessment, which included an evaluation of hand grip strength, gait speed, muscle mass and blood chemistry, including the concentration of 18 amino acids. Twenty-eight of the 160 participants met the criteria for sarcopenia established by the Asian Working Group on Sarcopenia in Older People. Univariate analysis revealed associations between the presence of sarcopenia and a higher plasma concentration of proline and glutamine, lower concentrations of histidine and tryptophan. Multivariable analysis revealed that a higher concentration of proline was the only variable independently associated with sarcopenia. The plasma concentration of proline may be useful for understanding the underlying pathophysiology of sarcopenia.

  8. Increased plasma proline concentrations are associated with sarcopenia in the elderly.

    Directory of Open Access Journals (Sweden)

    Kenji Toyoshima

    Full Text Available Metabolome analyses have shown that plasma amino acid profiles reflect various pathological conditions, such as cancer and diabetes mellitus. It remains unclear, however, whether plasma amino acid profiles change in patients with sarcopenia. This study therefore aimed to investigate whether sarcopenia-specific changes occur in plasma amino acid profiles.A total of 153 community-dwelling and seven institutionalized elderly individuals (56 men, 104 women; mean age, 77.7±7.0 years were recruited for this cross-sectional analysis. We performed a comprehensive geriatric assessment, which included an evaluation of hand grip strength, gait speed, muscle mass and blood chemistry, including the concentration of 18 amino acids.Twenty-eight of the 160 participants met the criteria for sarcopenia established by the Asian Working Group on Sarcopenia in Older People. Univariate analysis revealed associations between the presence of sarcopenia and a higher plasma concentration of proline and glutamine, lower concentrations of histidine and tryptophan. Multivariable analysis revealed that a higher concentration of proline was the only variable independently associated with sarcopenia.The plasma concentration of proline may be useful for understanding the underlying pathophysiology of sarcopenia.

  9. Risk factors associated with high linezolid trough plasma concentrations.

    Science.gov (United States)

    Morata, L; De la Calle, C; Gómez-Cerquera, J M; Manzanedo, L; Casals, G; Brunet, M; Cobos-Trigueros, N; Martínez, J A; Mensa, J; Soriano, A

    2016-06-01

    The major concern of linezolid is the adverse events. High linezolid trough serum concentration (Cmin) has been associated with toxicity. The aim of this study was to analyze factors associated with high Cmin. Main clinical characteristics of 104 patients treated with 600 mg/12 hours of linezolid were retrospectively reviewed. Samples were obtained just before the next dose after at least three doses and within the first 8 days of treatment. High Cmin was considered when it was >8 mg/L. Univariate and multivariate analysis were performed. 34.6% patients had a Cmin >8 mg/L, and they were older and had more frequently an estimated glomerular filtration by MDRD 8 was the renal function. Patients with an eGF 80 mL/min (OR: 4.273) and there was a trend towards a high Cmin in patients with eGF between 40-80 mL/min (OR: 2.109). High Cmin were frequent, especially in patients with MDRD <40 mL/min. Therapeutic drug monitoring could be useful to avoid toxicity in patients with renal dysfunction.

  10. Inverse association between plasma homocysteine concentrations and type 2 diabetes mellitus among a middle-aged and elderly Chinese population.

    Science.gov (United States)

    Yu, C; Wang, J; Wang, F; Han, X; Hu, H; Yuan, J; Miao, X; Yao, P; Wei, S; Wang, Y; Liang, Y; Chen, W; Zhang, X; Guo, H; Yang, H; Tang, Y; Zheng, D; Wu, T; He, M

    2018-03-01

    Plasma homocysteine concentrations have been reported to be associated with type 2 diabetes mellitus (T2DM) with controversial findings. The aim of the present study was to investigate the association between plasma homocysteine concentrations and T2DM. A cross-sectional study including 19,085 eligible participants derived from the Dongfeng-Tongji cohort was conducted. Plasma homocysteine concentrations were measured by Abbott Architect i2000 Automatic analyzer and T2DM was defined according to American Diabetes Association criteria. Logistic regression model was used to explore the association between plasma homocysteine concentrations and T2DM. The prevalence of T2DM was 19.0% in the whole population (mean age 62.9 years), 21.8% in males, and 17.1% in females. In the multivariable logistic regression analyses, compared with those in the lowest quintile, the OR (95% CI) of T2DM was 1.05 (0.92-1.21), 0.99 (0.86-1.14), 0.90 (0.78-1.05), and 0.77 (0.66-0.90) for quintile 2 to quintile 5 of homocysteine concentrations after adjustment for potential confounders (P for trend associated with decreased T2DM prevalence risk (OR = 0.88 per SD increase of homocysteine concentration; 95% CI: 0.84-0.93). A significant interaction between homocysteine concentrations and drinking status on T2DM prevalence risk was observed (P for interaction = 0.03). The inverse association of plasma homocysteine concentrations with T2DM prevalence risk was observed in non-drinkers but not in current drinkers. Plasma homocysteine concentrations were inversely correlated with T2DM among a middle-aged and elderly Chinese population. Copyright © 2017 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  11. Nondestructive measurement for radionuclide concentration distribution in soil column

    International Nuclear Information System (INIS)

    Ogawa, Hiromichi; Ohnuki, Toshihiko; Yamamoto, Tadatoshi; Wadachi, Yoshiki

    1985-01-01

    A nondestructive method has been studied for determining the concentration of radionuclide (Cs-137) distributed in a soil column. The concentration distribution was calculated from the counting rate distribution using the efficiency matrix of a detector. The concentration distribution obtained by this method, with measuring efficiencies of theoretical calculation, coincides well with that obtained by the destructive sampling method. This method is, therefore, found to be effective for the measurement of one dimensional concentration distribution. The measuring limit of this method is affected not only by the radionuclide concentration but also by the shape of concentration distribution in a soil column and also by the way it is divided into concentration blocks. It is found that, the radioactive concentration up to 2.6 x 10 -4 μCi/g (9.62 Bq/g), and also the distribution up to where the concentration reduces to half at every 1 cm of depth, can be measured by this system. The concentration blocks can be divided into 1 cm of thickness as a minimum value. (author)

  12. Design and testing of miniaturized plasma sensor for measuring hypervelocity impact plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Goel, A., E-mail: ashish09@stanford.edu; Tarantino, P. M.; Lauben, D. S.; Close, S. [Department of Aeronautics and Astronautics, Stanford University, Stanford, California 94305 (United States)

    2015-04-15

    An increasingly notable component of the space environment pertains to the impact of meteoroids and orbital debris on spacecraft and the resulting mechanical and electrical damages. Traveling at speeds of tens of km/s, when these particles, collectively referred to as hypervelocity particles, impact a satellite, they vaporize, ionize, and produce a radially expanding plasma that can generate electrically harmful radio frequency emission or serve as a trigger for electrostatic discharge. In order to measure the flux, composition, energy distribution, and temperature of ions and electrons in this plasma, a miniaturized plasma sensor has been developed for carrying out in-situ measurements in space. The sensor comprises an array of electrostatic analyzer wells split into 16 different channels, catering to different species and energy ranges in the plasma. We present results from numerical simulation based optimization of sensor geometry. A novel approach of fabricating the sensor using printed circuit boards is implemented. We also describe the test setup used for calibrating the sensor and show results demonstrating the energy band pass characteristics of the sensor. In addition to the hypervelocity impact plasmas, the plasma sensor developed can also be used to carry out measurements of ionospheric plasma, diagnostics of plasma propulsion systems, and in other space physics experiments.

  13. Vitamin C Deficiency Reduces Muscarinic Receptor Coronary Artery Vasoconstriction and Plasma Tetrahydrobiopterin Concentration in Guinea Pigs

    Directory of Open Access Journals (Sweden)

    Gry Freja Skovsted

    2017-07-01

    Full Text Available Vitamin C (vitC deficiency is associated with increased cardiovascular disease risk, but its specific interplay with arteriolar function is unclear. This study investigates the effect of vitC deficiency in guinea pigs on plasma biopterin status and the vasomotor responses in coronary arteries exposed to vasoconstrictor/-dilator agents. Dunkin Hartley female guinea pigs (n = 32 were randomized to high (1500 mg/kg diet or low (0 to 50 mg/kg diet vitC for 10–12 weeks. At euthanasia, coronary artery segments were dissected and mounted in a wire-myograph. Vasomotor responses to potassium, carbachol, sodium nitroprusside (SNP, U46619, sarafotoxin 6c (S6c and endothelin-1 (ET-1 were recorded. Plasma vitC and tetrahydrobiopterin were measured by HPLC. Plasma vitC status reflected the diets with deficient animals displaying reduced tetrahydrobiopterin. Vasoconstrictor responses to carbachol were significantly decreased in vitC deficient coronary arteries independent of their general vasoconstrictor/vasodilator capacity (p < 0.001. Moreover, in vitC deficient animals, carbachol-induced vasodilator responses correlated with coronary artery diameter (p < 0.001. Inhibition of cyclooxygenases with indomethacin increased carbachol-induced vasoconstriction, suggesting an augmented carbachol-induced release of vasodilator prostanoids. Atropine abolished carbachol-induced vasomotion, supporting a specific muscarinic receptor effect. Arterial responses to SNP, potassium, S6c, U46619 and ET-1 were unaffected by vitC status. The study shows that vitC deficiency decreases tetrahydrobiopterin concentrations and muscarinic receptor mediated contraction in coronary arteries. This attenuated vasoconstrictor response may be linked to altered production of vasoactive arachidonic acid metabolites and reduced muscarinic receptor expression/signaling.

  14. Influence of inulin on plasma isoflavone concentrations in healthy postmenopausal women.

    Science.gov (United States)

    Piazza, Cateno; Privitera, Maria Giovanna; Melilli, Barbara; Incognito, Tiziana; Marano, Maria Rosa; Leggio, Gian Marco; Roxas, Matilde Amico; Drago, Filippo

    2007-09-01

    Bacterial intestinal glucosidases exert an important role in isoflavone absorption. Insoluble dietary fibers such as inulin may stimulate the growth of these bacteria in the colon and, hence, stimulate the absorption of these substances in subjects who may need isoflavone supplementation. The objective was to assess the influence of inulin on plasma isoflavone concentrations after intake of soybean isoflavones in healthy postmenopausal women. Twelve healthy postmenopausal women participated in a randomized, double-blind, crossover study. They consumed 40 mg of a conjugated form of soybean isoflavones (6 mg daidzein and 18 mg genistein as free form) with or without 3.66 g inulin twice daily in two 21-d experimental phases. Blood samples were collected 0, 1, 2, 3, 4, 6, 10, 12, and 24 h after intake of isoflavones with breakfast and dinner at the end of each 21-d experimental phase. Plasma concentrations of isoflavones were assessed by HPLC with an electrochemical detector. Plasma 24-h areas under the curve indicated that the intake of soybean isoflavones with inulin for 21 d was followed by higher plasma concentrations of daidzein and genistein (38% and 91%, respectively) compared with the formulation without inulin. Furthermore, the time for the maximum concentration of daidzein and genistein appeared to be lower after the 21-d intake of soybean isoflavones, with or without inulin. However, the time for the maximum concentration of daidzein and genistein after supplementation with the inulin-containing formulation on day 21 was not significantly different from that after supplementation with the formulation without inulin. Inulin may increase the apparent plasma concentrations of the soybean isoflavones daidzein and genistein in postmenopausal women. The higher plasma concentrations of the 2 isoflavones suggests that the absorption of each was facilitated by the presence of inulin.

  15. Age- and gender-related alteration in plasma advanced oxidation protein products (AOPP) and glycosaminoglycan (GAG) concentrations in physiological ageing.

    Science.gov (United States)

    Komosinska-Vassev, Katarzyna; Olczyk, Pawel; Winsz-Szczotka, Katarzyna; Kuznik-Trocha, Kornelia; Klimek, Katarzyna; Olczyk, Krystyna

    2012-02-13

    The authors studied the role of increased oxidative stress in the development of oxidative protein damage and extracellular matrix (ECM) components in ageing. The age- and gender-associated disturbances in connective tissue metabolism were evaluated by the plasma chondroitin sulphated glycosaminoglycans (CS-GAG) and non-sulphated GAG-hyaluronan (HA) measurements. Plasma concentration of advanced oxidation protein products (AOPP) was analysed in order to assess oxidative protein damage and evaluate the possible deleterious role of oxidative phenomenon on tissue proteoglycans' metabolism during the physiological ageing process. Sulphated and non-sulphated GAGs as well as AOPP were quantified in plasma samples from 177 healthy volunteers. A linear age-related decline of plasma CS-GAG level was found in this study (r=-0.46; page (r=0.44; page-dependent relationship has been shown in regard to AOPP. AOPP levels significantly increased with age (r=0.63; pphysiological ageing. A significant correlation was found between the concentrations of AOPP and both CS-GAG (r=-0.31; page changes in the ECM are reflected by CS-GAG and HA plasma levels. Strong correlations between AOPP and ECM components indicate that oxidative stress targets protein and non-protein components of the connective tissue matrix during human ageing.

  16. Single-shot optical conductivity measurement of dense aluminum plasmas

    International Nuclear Information System (INIS)

    Churina, I. V.; Cho, B.-I.; Bernstein, A.; Stoker, D. S.; Dalton, A.; Symes, D. R.; Ditmire, T.

    2009-01-01

    The optical conductivity of a dense femtosecond laser-heated aluminum plasma heated to 0.1-1.5 eV was measured using frequency-domain interferometry with chirped pulses, permitting simultaneous observation of optical probe reflectivity and probe pulse phase shift. Coupled with published models of bound-electron contributions to the conductivity, these two independent experimental data yielded a direct measurement of both real and imaginary components of the plasma conductivity.

  17. The plasma carnitine concentration regulates renal OCTN2 expression and carnitine transport in rats

    OpenAIRE

    Schürch, R; Todesco, L; Novakova, K; Mevissen, M; Stieger, B; Krähenbühl, S

    2010-01-01

    Previous findings in rats and in human vegetarians suggest that the plasma carnitine concentration and/or carnitine ingestion may influence the renal reabsorption of carnitine. We tested this hypothesis in rats with secondary carnitine deficiency following treatment with N-trimethyl-hydrazine-3-propionate (THP) for 2 weeks and rats treated with excess L-carnitine for 2 weeks. Compared to untreated control rats, treatment with THP was associated with an approximately 70% decrease in plasma car...

  18. Negative symptoms in nondeficit syndrome respond to neuroleptic treatment with changes in plasma homovanillic acid concentrations.

    OpenAIRE

    Suzuki, E; Kanba, S; Koshikawa, H; Nibuya, M; Yagi, G; Asai, M

    1996-01-01

    Deficit syndrome (DS) in schizophrenia is characterized by serious, chronic, and primary negative symptoms. We investigated differences in response to neuroleptic treatment between 8 DS patients and 6 nondeficit syndrome (NDS) patients who had the selective dopamine-D2 receptor blocker bromperidol added to their neuroleptic regimens. First, 9 mg/d was administered for 4 weeks, followed by 18 mg/d for another 4 weeks. Plasma homovanillic acid (pHVA) and plasma bromperidol concentrations were m...

  19. Dietary modulation of plasma angiopoietin-like protein 4 concentrations in healthy volunteers and in patients with type 2 diabetes

    NARCIS (Netherlands)

    Jonker, Jacqueline T.; Smit, Johannes W. A.; Hammer, Sebastiaan; Snel, Marieke; van der Meer, Rutger W.; Lamb, Hildo J.; Mattijssen, Frits; Mudde, Karin; Jazet, Ingrid M.; Dekkers, Olaf M.; de Roos, Albert; Romijn, Johannes A.; Kersten, Sander; Rensen, Patrick C. N.

    2013-01-01

    Angiopoietin-like protein 4 (ANGPTL4) has been identified as an inhibitor of lipoprotein lipase. Preliminary data suggest that plasma nonesterified fatty acids (NEFAs) raise plasma ANGPTL4 concentrations in humans. The objective was to assess plasma ANGPTL4 concentrations after various nutritional

  20. Dietary modulation of plasma angiopoietin-like protein 4 concentrations in healthy volunteers and in patients with type 2 diabetes

    NARCIS (Netherlands)

    Jonker, J.T.; Smit, J.W.A.; Hammer, S.; Snel, M.; Meer, R.W. van der; Lamb, H.J.; Mattijssen, F.; Mudde, K.; Jazet, I.M.; Dekkers, O.M.; Roos, A. de; Romijn, J.A.; Kersten, S.; Rensen, P.C.

    2013-01-01

    BACKGROUND: Angiopoietin-like protein 4 (ANGPTL4) has been identified as an inhibitor of lipoprotein lipase. Preliminary data suggest that plasma nonesterified fatty acids (NEFAs) raise plasma ANGPTL4 concentrations in humans. OBJECTIVE: The objective was to assess plasma ANGPTL4 concentrations

  1. Dietary modulation of plasma angiopoietin-like protein 4 concentrations in healthy volunteers and in patients with type 2 diabetes

    NARCIS (Netherlands)

    Jonker, J.T.; Smit, J.W.A.; Hammer, S.; Snel, M.; Meer, van der R.; Lamb, H.J.; Mattijssen, F.B.J.; Mudde, C.M.; Jazet, I.M.; Dekkers, O.M.; Roos, de A.; Romijn, J.A.; Kersten, A.H.; Rensen, P.C.N.

    2013-01-01

    Background: Angiopoietin-like protein 4 (ANGPTL4) has been identified as an inhibitor of lipoprotein lipase. Preliminary data suggest that plasma nonesterified fatty acids (NEFAs) raise plasma ANGPTL4 concentrations in humans. Objective: The objective was to assess plasma ANGPTL4 concentrations

  2. Fever and changes in plasma zinc and iron concentrations in the goat: The role of leukocytic pyrogen

    NARCIS (Netherlands)

    Verheijden, J.H.M.; Miert, A. S. J. P. A. M. Van; Duin, C.T.M. van; Schotman, A.J.H.; Nieuwenhuis, J.

    1984-01-01

    In goats with trypanosomiasis (T. vivax or T. congolense) no marked fall in plasma zinc concentration was seen despite high temperature peaks, whereas plasma concentrations of iron tended to undergo some decline. In goats infected with Ehrlichia phagocytophila, there was a marked decline in plasma

  3. [Measurement of maternal plasma volume during pregnancy].

    Science.gov (United States)

    Uzan, S; Beaufils, M; Uzan, M; Donsimoni, R; Mareck, A; Salat-Baroux, J; Sureau, C

    1988-02-01

    An increased maternal plasma volume (PV) is a characteristic phenomenon of normal pregnancy, which may be related to a physiological decrease of peripheral resistances. The authors have studied the plasma volume of 1,105 patients distributed as follows: normal (387), permanently hypertensive patients (84), hypertensive patients during pregnancy (390), patients with apparently isolated RCIU (154) or with a pathological past-history during previous pregnancies (90). It appears that the PV is a sign of a severe HBP, and presents a rather early and good predictive value regarding the weight of the fetus and some complications such as severe UCIU and fetal death in utero. In case of pathological past events or pre-existing hypertension, the PV enables to differentiate rather well patients who will be prone to a complicated pregnancy. In view of these results, utilization and interpretation criteria of this parameter during pregnancies with hypertension or pregnancies in which there is a suspicion or a risk of intra-uterine growth delay, are defined.

  4. Concentration of Potassium in Plasma, Erythrocytes, and Muscle Tissue in Cows with Decreased Feed Intake and Gastrointestinal Ileus.

    Science.gov (United States)

    Schneider, S; Müller, A; Wittek, T

    2016-01-01

    Healthy cows consume large amounts of potassium and a sudden loss in appetite can lead to hypokalemia. The routine method to evaluate potassium homeostasis is the measurement of the extracellular potassium in plasma or serum, but this does not provide information about the intracellular potassium pool. To evaluate potassium homeostasis by comparing the extracellular and intracellular potassium concentration in cows with reduced feed intake and gastrointestinal ileus. Twenty cows 1-3 days postpartum (group 1) and 20 cows with gastrointestinal ileus (group 2). Observational cross-sectional study. Plasma potassium was measured by using an ion-sensitive electrode. Intracellular potassium was measured in erythrocytes and muscle tissue (muscle biopsy) by using inductively coupled plasma optical emission spectroscopy. Cows of group 1 did not have hypokalemia. Overall cows with gastrointestinal ileus were hypokalemic (mean ± SD, 2.9 mmol/L ± 0.78), but potassium concentration in erythrocytes and muscle tissue was not lower than in postpartum cows. Intracellular potassium in erythrocytes varied very widely; group 1: 3497-10735 mg/kg (5559 ± 2002 mg/kg), group 2: 4139-21678 mg/kg (7473 ± 4034 mg/kg). Potassium in muscle tissue did not differ between group 1 (3356 ± 735 mg/kg wet weight) and group 2 (3407 ± 1069 mg/kg wet weight). No association between extracellular and intracellular potassium concentrations was detected. That measurement of plasma potassium concentration is not sufficient to evaluate potassium metabolism of cows. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  5. MiOXSYS: a novel method of measuring oxidation reduction potential in semen and seminal plasma.

    Science.gov (United States)

    Agarwal, Ashok; Sharma, Rakesh; Roychoudhury, Shubhadeep; Du Plessis, Stefan; Sabanegh, Edmund

    2016-09-01

    To measure oxidative reduction potential (ORP) in semen and seminal plasma and to establish their reference levels. ORP levels were measured in semen and seminal plasma. Tertiary hospital. Twenty-six controls and 33 infertile men. None. Static ORP (sORP) and capacitance ORP (cORP) were measured in semen and seminal plasma at time 0 and 120 minutes. Correlation of ORP was assessed between [1] semen and seminal plasma and [2] time 0 and 120 minutes. The association with sperm parameters was studied in (a) controls and (b) infertile patients, and a receiver operating characteristic curve was generated to establish the sORP cutoff. Semen sORP and cORP levels were associated with seminal plasma levels at time 0 and time 120 minutes. In controls and infertile patients, an inverse relationship of sORP levels was established with concentration and total sperm count in semen as well as seminal plasma at time 0 and 120 minutes. Classification of subjects based on sperm motility showed that subjects with abnormal motility present with poor concentration, total count, morphology, and elevated levels of semen and seminal plasma sORP at time 120 minutes. The sORP cutoff of 1.48 in semen and 2.09 in seminal plasma based on motility was able to distinguish subjects with normal semen quality from those with abnormal semen quality. The MiOXSYS System can reliably measure ORP levels in semen and seminal plasma. ORP levels are not affected by semen age, making this new technology easy to employ in a clinical setting. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  6. Phytosterol plasma concentrations and coronary heart disease in the prospective Spanish EPIC cohort

    Science.gov (United States)

    Escurriol, Verónica; Cofán, Montserrat; Moreno-Iribas, Concepción; Larrañaga, Nerea; Martínez, Carmen; Navarro, Carmen; Rodríguez, Laudina; González, Carlos A.; Corella, Dolores; Ros, Emilio

    2010-01-01

    Phytosterol intake with natural foods, a measure of healthy dietary choices, increases plasma levels, but increased plasma phytosterols are believed to be a coronary heart disease (CHD) risk factor. To address this paradox, we evaluated baseline risk factors, phytosterol intake, and plasma noncholesterol sterol levels in participants of a case control study nested within the European Prospective Investigation into Cancer and Nutrition (EPIC) Spanish cohort who developed CHD (n = 299) and matched controls (n = 584) who remained free of CHD after a 10 year follow-up. Sitosterol-to-cholesterol ratios increased across tertiles of phytosterol intake (P = 0.026). HDL-cholesterol level increased, and adiposity measures, cholesterol/HDL ratios, and levels of glucose, triglycerides, and lathosterol, a cholesterol synthesis marker, decreased across plasma sitosterol tertiles (P phytosterol intake and plasma sitosterol. The multivariable-adjusted odds ratio for CHD across the lowest to highest plasma sitosterol tertile was 0.59 (95% confidence interval, 0.36–0.97). Associations were weaker for plasma campesterol. The apolipoprotein E genotype was unrelated to CHD risk or plasma phytosterols. The data suggest that plasma sitosterol levels are associated with a lower CHD risk while being markers of a lower cardiometabolic risk in the EPIC-Spain cohort, a population with a high phytosterol intake. PMID:19786566

  7. Treatment with cinacalcet increases plasma sclerostin concentration in hemodialysis patients with secondary hyperparathyroidism.

    Science.gov (United States)

    Kuczera, Piotr; Adamczak, Marcin; Więcek, Andrzej

    2016-11-15

    Sclerostin is a paracrine acting factor, which is expressed in the osteocytes and articular chondrocytes. Sclerostin decreases the osteoblast-related bone formation through the inhibition of the Wnt/β-catenin pathway. Osteocytes also express the Calcium sensing receptor which is a target for cinacalcet. The aim of this study was to assess the influence of six-month cinacalcet treatment on plasma sclerostin concentration in hemodialysed patients with secondary hyperparathyroidism (sHPT). In 58 hemodialysed patients with sHPT (PTH > 300 pg/ml) plasma sclerostin and serum PTH, calcium and phosphate concentrations were assessed before the first dose of cinacalcet and after 3 and 6 months of treatment. Serum PTH concentration decreased after 3 and 6 month of treatment from 1138 (931-1345) pg/ml to 772 (551-992) pg/ml and to 635 (430-839) pg/ml, respectively. Mean serum calcium and phosphate concentrations remained stable. Plasma sclerostin concentration increased after 3 and 6 months of treatment from 1.66 (1.35-1.96) ng/ml, to 1.77 (1.43-2.12) ng/ml and to 1.87 (1.50-2.25) ng/ml, respectively. In 42 patients with cinacalcet induced serum PTH decrease plasma sclerostin concentration increased after 3 and 6 months of treatment from 1.51 (1.19-1.84) ng/ml to 1.59 (1.29-1.89) ng/ml and to 1.75 (1.42-2.01) ng/ml, respectively. Contrary, in the 16 patients without cinacalcet induced serum PTH decrease plasma sclerostin concentration was stable. Plasma sclerostin concentrations correlated inversely with serum PTH concentrations at the baseline and also after 6 months of treatment. 1. In hemodialysed patients with secondary hyperparathyroidism treatment with cinacalcet increases plasma sclerostin concentration 2. This effect seems to be related to decrease of serum PTH concentration.

  8. [Effects of dietary wheat gluten level on decreasing plasma homocysteine concentration in rats].

    Science.gov (United States)

    Liu, Yiqun; Han, Feng; Sun, Licui; Lu, Jiaxi; Sugiyama, Kimio; Huang, Zhenwu

    2015-05-01

    To investigate the effects of different level of casein and wheat gluten on decreasing plasma homocysteine concentration in rats. 48 rats of the Wistar were fed with different level of casein (12.5%, 25% and 50%) and wheat gluten (14.5%, 29% and 58%) diets for 14 days, and they were killed by decapitation to obtain blood and livers was subject to analysis the concentration of homocysteine, cysteine and other amino acids, as well as BHMT and CBS activities. Body weight gain in rats fed wheat gluten dietary was significantly less than casein dietary, but food intake was significantly decreased in wheat gluten group with increasing of the protein content. The plasma homocysteine concentration in rats fed wheat gluten was marketly less than casein, however plasma cysteine concentration in wheat gluten was higher than casein group. The effects of wheat gluten on plasma homocysteine concentration are mainly depends on the low contents of methionine and high cysteine content, but the low contents of lyscine and threonine are not ignored. The mainly mechanism is that the increased cysteine concentration promot enzyme activities of homocystein metabolism, and increase the consumption of homocysteine.

  9. Power law relation between particle concentrations and their sizes in the blood plasma

    International Nuclear Information System (INIS)

    Kirichenko, M N; Chaikov, L L; Zaritskii, A R

    2016-01-01

    This work is devoted to the investigation of sizes and concentrations of particles in blood plasma by dynamic light scattering (DLS). Blood plasma contains many different proteins and their aggregates, microparticles and vesicles. Their sizes, concentrations and shapes can give information about donor's health. Our DLS study of blood plasma reveals unexpected dependence: with increasing of the particle sizes r (from 1 nm up to 1 μm), their concentrations decrease as r -4 (almost by 12 orders). We found also that such dependence was repeated for model solution of fibrinogen and thrombin with power coefficient is -3,6. We believe that this relation is a fundamental law of nature that shows interaction of proteins (and other substances) in biological liquids. (paper)

  10. Plasma potential measurements in the edge region of the ISTTOK plasma, using electron emissive probes

    International Nuclear Information System (INIS)

    Ionita, C.; Balan, P.; Schrittwieser, R.; Cabral, J.A.; Fernandes, H.; Figueiredo, H. F.C.; Varandas, C.

    2001-01-01

    We have recently started to use electron-emissive probes for direct measurements of the plasma potential and its fluctuations in the edge region of the plasma ring in the tokamak ISTTOK in Lisbon, Portugal. This method is based on the fact that the electron emission current of such a probe is able to compensate electron temperature variations and electron drifts, which can occur in the edge plasma region of magnetized fusion devices, and which are making measurements with cold probes prone to errors. In this contribution we present some of the first results of our investigations in ISTTOK.(author)

  11. Simulation of density measurements in plasma wakefields using photo acceleration

    CERN Document Server

    Kasim, Muhammad Firmansyah; Ceurvorst, Luke; Sadler, James; Burrows, Philip N; Trines, Raoul; Holloway, James; Wing, Matthew; Bingham, Robert; Norreys, Peter

    2015-01-01

    One obstacle in plasma accelerator development is the limitation of techniques to diagnose and measure plasma wakefield parameters. In this paper, we present a novel concept for the density measurement of a plasma wakefield using photon acceleration, supported by extensive particle in cell simulations of a laser pulse that copropagates with a wakefield. The technique can provide the perturbed electron density profile in the laser’s reference frame, averaged over the propagation length, to be accurate within 10%. We discuss the limitations that affect the measurement: small frequency changes, photon trapping, laser displacement, stimulated Raman scattering, and laser beam divergence. By considering these processes, one can determine the optimal parameters of the laser pulse and its propagation length. This new technique allows a characterization of the density perturbation within a plasma wakefield accelerator.

  12. Simulation of density measurements in plasma wakefields using photon acceleration

    Directory of Open Access Journals (Sweden)

    Muhammad Firmansyah Kasim

    2015-03-01

    Full Text Available One obstacle in plasma accelerator development is the limitation of techniques to diagnose and measure plasma wakefield parameters. In this paper, we present a novel concept for the density measurement of a plasma wakefield using photon acceleration, supported by extensive particle in cell simulations of a laser pulse that copropagates with a wakefield. The technique can provide the perturbed electron density profile in the laser’s reference frame, averaged over the propagation length, to be accurate within 10%. We discuss the limitations that affect the measurement: small frequency changes, photon trapping, laser displacement, stimulated Raman scattering, and laser beam divergence. By considering these processes, one can determine the optimal parameters of the laser pulse and its propagation length. This new technique allows a characterization of the density perturbation within a plasma wakefield accelerator.

  13. Gas and particle velocity measurements in an induction plasma

    International Nuclear Information System (INIS)

    Lesinski, J.; Gagne, R.; Boulos, M.I.

    1981-08-01

    Laser doppler anemometry was used for the measurements of the plasma and particle velocity profiles in the coil region of an inductively coupled plasma. Results are reported for a 50 mm ID induction torch operated at atmospheric pressure with argon as the plasma gas. The oscillator frequency was 3 MHz and the power in the coil was varied between 4.6 and 10.5 kW. The gas velocity measurements were made using a fine carbon powder as a tracer (dp approx. = 1 μm). Measurements were also made with larger silicon particles (dp = 33 μm and sigma = 13 μm) centrally injected in the plasma under different operating conditions

  14. Nitrate-Rich Vegetables Increase Plasma Nitrate and Nitrite Concentrations and Lower Blood Pressure in Healthy Adults.

    Science.gov (United States)

    Jonvik, Kristin L; Nyakayiru, Jean; Pinckaers, Philippe Jm; Senden, Joan Mg; van Loon, Luc Jc; Verdijk, Lex B

    2016-05-01

    Dietary nitrate is receiving increased attention due to its reported ergogenic and cardioprotective properties. The extent to which ingestion of various nitrate-rich vegetables increases postprandial plasma nitrate and nitrite concentrations and lowers blood pressure is currently unknown. We aimed to assess the impact of ingesting different nitrate-rich vegetables on subsequent plasma nitrate and nitrite concentrations and resting blood pressure in healthy normotensive individuals. With the use of a semirandomized crossover design, 11 men and 7 women [mean ± SEM age: 28 ± 1 y; mean ± SEM body mass index (BMI, in kg/m(2)): 23 ± 1; exercise: 1-10 h/wk] ingested 4 different beverages, each containing 800 mg (∼12.9 mmol) nitrate: sodium nitrate (NaNO3), concentrated beetroot juice, a rocket salad beverage, and a spinach beverage. Plasma nitrate and nitrite concentrations and blood pressure were determined before and up to 300 min after beverage ingestion. Data were analyzed using repeated-measures ANOVA. Plasma nitrate and nitrite concentrations increased after ingestion of all 4 beverages (P nitrate concentrations were similar for all treatments (all values presented as means ± SEMs: NaNO3: 583 ± 29 μmol/L; beetroot juice: 597 ± 23 μmol/L; rocket salad beverage: 584 ± 24 μmol/L; spinach beverage: 584 ± 23 μmol/L). Peak plasma nitrite concentrations were different between treatments (NaNO3: 580 ± 58 nmol/L; beetroot juice: 557 ± 57 nmol/L; rocket salad beverage: 643 ± 63 nmol/L; spinach beverage: 980 ± 160 nmol/L; P = 0.016). When compared with baseline, systolic blood pressure declined 150 min after ingestion of beetroot juice (from 118 ± 2 to 113 ± 2 mm Hg; P nitrate-rich beetroot juice, rocket salad beverage, and spinach beverage effectively increases plasma nitrate and nitrite concentrations and lowers blood pressure to a greater extent than sodium nitrate. These findings show that nitrate-rich vegetables can be used as dietary nitrate

  15. Concentrations of danofloxacin 18% solution in plasma, milk and tissues after subcutaneous injection in dairy cows

    International Nuclear Information System (INIS)

    Mestorino, N.; Marchetti, M.L.; Turic, E.; Pesoa, J.; Errecalde, J.

    2009-01-01

    Danofloxacin is a fluoroquinolone developed for use in veterinary medicine. Its concentrations and pharmacokinetic profile in plasma, milk and tissues of lactating dairy cows were determined, and its milk withdrawal time (WT) calculated. Twenty-one dairy cows received a single subcutaneous administration of 18% mesylate danofloxacin salt (6 mg kg -1 ). Plasma and milk samples were obtained at different times until 48 h. Groups of three animals were sacrificed at different post-administration times and tissue samples (mammary gland, uterus, duodenum, jejunum, ileum, colon and mesenteric lymph nodes) obtained. Danofloxacin concentrations were determined by liquid chromatography with fluorescence detection. The milk WT was calculated by the Time to Safe Concentration method (Software WTM 1.4, EMEA). Danofloxacin was rapidly absorbed and its distribution from plasma to all sampled tissues and milk was extensive. Milk and tissues concentrations were several times above those found in plasma. Plasma area under the curve (AUCp) was 9.69 μg h mL -1 and its elimination half life (T β 1/2 ) was 12.53 h. AUC values for the various tissues and milk greatly exceeded AUCp. T β 1/2 from milk and tissues ranged between 4.57 and 21.91 h and the milk withdrawal time was 73.48 h. The reported results support the potential use of danofloxacin in the treatment of mastitis and other infections in milk cows with 3 days of withdrawal

  16. Forced swimming and imipramine modify plasma and brain amino acid concentrations in mice.

    Science.gov (United States)

    Murakami, Tatsuro; Yamane, Haruka; Tomonaga, Shozo; Furuse, Mitsuhiro

    2009-01-05

    The relationships between monoamine metabolism and forced swimming or antidepressants have been well studied, however information is lacking regarding amino acid metabolism under these conditions. Therefore, the aim of the present study was to investigate the effects of forced swimming and imipramine on amino acid concentrations in plasma, the cerebral cortex and the hypothalamus in mice. Forced swimming caused cerebral cortex concentrations of L-glutamine, L-alanine, and taurine to be increased, while imipramine treatment caused decreased concentrations of L-glutamate, L-alanine, L-tyrosine, L-methionine, and L-ornithine. In the hypothalamus, forced swimming decreased the concentration of L-serine while imipramine treatment caused increased concentration of beta-alanine. Forced swimming caused increased plasma concentration of taurine, while concentrations of L-serine, L-asparagine, L-glutamine and beta-alanine were decreased. Imipramine treatment caused increased plasma concentration of all amino acid, except for L-aspartate and taurine. In conclusion, forced swimming and imipramine treatment modify central and peripheral amino acid metabolism. These results may aid in the identification of amino acids that have antidepressant-like effects, or may help to refine the dosages of antidepressant drugs.

  17. Magnetic Field Measurements In Magnetized Plasmas Using Zeeman Broadening Diagnostics

    Science.gov (United States)

    Haque, Showera; Wallace, Matthew; Presura, Radu; Neill, Paul

    2017-10-01

    The Zeeman effect has been used to measure the magnetic field in high energy density plasmas. This method is limited when plasma conditions are such that the line broadening due to the high plasma density and temperature surpasses the Zeeman splitting. We have measured magnetic fields in magnetized laser plasmas under conditions where the Zeeman splitting was not spectrally resolved. The magnetic field strength was determined from the difference in widths of two doublet components, using an idea proposed by Tessarin et al. (2011). Time-gated spectra with one-dimensional space-resolution were obtained at the Nevada Terawatt Facility for laser plasmas created by 20 J, 1 ns Leopard laser pulses, and expanding in the azimuthal magnetic field produced by the 0.6 MA Zebra pulsed power generator. We explore the response of the Al III 4s 2S1/2 - 4p 2P1 / 2 , 3 / 2 doublet components to the external magnetic field spatially along the plasma. Radial magnetic field and electron density profiles were measured within the plasma plume. This work was supported by the DOE/OFES Grant DE-SC0008829 and DOE/NNSA contract DE-FC52-06NA27616.

  18. Concentrations of thiocyanate and goitrin in human plasma, their precursor concentrations in brassica vegetables, and associated potential risk for hypothyroidism.

    Science.gov (United States)

    Felker, Peter; Bunch, Ronald; Leung, Angela M

    2016-04-01

    Brassica vegetables are common components of the diet and have beneficial as well as potentially adverse health effects. Following enzymatic breakdown, some glucosinolates in brassica vegetables produce sulforaphane, phenethyl, and indolylic isothiocyanates that possess anticarcinogenic activity. In contrast, progoitrin and indolylic glucosinolates degrade to goitrin and thiocyanate, respectively, and may decrease thyroid hormone production. Radioiodine uptake to the thyroid is inhibited by 194 μmol of goitrin, but not by 77 μmol of goitrin. Collards, Brussels sprouts, and some Russian kale (Brassica napus) contain sufficient goitrin to potentially decrease iodine uptake by the thyroid. However, turnip tops, commercial broccoli, broccoli rabe, and kale belonging to Brassica oleracae contain less than 10 μmol of goitrin per 100-g serving and can be considered of minimal risk. Using sulforaphane plasma levels following glucoraphanin ingestion as a surrogate for thiocyanate plasma concentrations after indole glucosinolate ingestion, the maximum thiocyanate contribution from indole glucosinolate degradation is estimated to be 10 μM, which is significantly lower than background plasma thiocyanate concentrations (40-69 μM). Thiocyanate generated from consumption of indole glucosinolate can be assumed to have minimal adverse risks for thyroid health. © The Author(s) 2016. Published by Oxford University Press on behalf of the International Life Sciences Institute. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  19. Measured and calculated NO2 concentrations in Amsterdam in 2008

    International Nuclear Information System (INIS)

    Wesseling, J.P.; Nguyen, P.L.; Van der Zee, S.

    2010-08-01

    Calculations using the Dutch standard calculation method for air quality in urban streets performed for 38 streets in Amsterdam in 2008 yield, on average, lower Nitrogen dioxide concentrations than measurements at those locations. This follows from research by the RIVM and the Public Health Service of Amsterdam (GGD Amsterdam). The average difference between measured and calculated concentrations is 11 %. At measuring locations of the National Air Quality Measuring Network in the Netherlands no significant underestimation of concentrations by the model is observed. The research was performed by the Dutch ministry of Housing, Spatial Planning en the Environment (VROM). The air quality in the streets that were investigated is mainly determined by emissions from local traffic. The measurements have been performed during thirteen periods of four weeks each, using so called 'Palmes' diffusion tubes. These measurements have been calibrated using the European reference method that is operational in the permanent measuring stations of the GGD Amsterdam. The calculations were performed using the geometry of the roads and information of the traffic at the measuring locations. Part of the differences can be explained, as some locations are not within the scope of the model. In these situations the model is known to perform slightly less. Apart from local traffic, other sources, like shipping, also contribute to the NO2 background concentrations in streets in Amsterdam. Sources that have only globally been included in the calculation of this background concentration may influence concentrations at specific locations. Further studies on this subject will be conducted in 2010. [nl

  20. Plasma concentrations of soluble urokinase-type plasminogen activator receptor are increased in patients with malaria and are associated with a poor clinical or a fatal outcome

    DEFF Research Database (Denmark)

    Ostrowski, Sisse R; Ullum, Henrik; Goka, Bamenla Q

    2005-01-01

    PAR are associated with disease severity in malaria. METHODS: At admission to the hospital, plasma concentrations of suPAR were measured by ELISA in samples from 645 African children with clinical symptoms of malaria: 478 had malaria, and 167 had a blood film negative for Plasmodium parasites. Fourteen healthy......BACKGROUND: Blood concentrations of soluble urokinase-type plasminogen activator receptor (suPAR) are increased in conditions with immune activation, and high concentrations of suPAR often predict a poor clinical outcome. This study explored the hypothesis that high plasma concentrations of su......: If the plasma concentration of suPAR reflects the extent of parasite-induced immune activation, this may explain why a high concentration of suPAR is associated with a poor clinical outcome in patients with malaria....

  1. Setting-up and validation of two radioimmunoassay methods for determination of plasma progesterone concentration in mares, cows and rats

    International Nuclear Information System (INIS)

    Rosa e Silva, A.A.M.; Caldas, M.C.S.; Campos, L.M.A.; Gradela, A.

    1993-01-01

    Two reliable radioimmunoassay (RIA) methods which permits the measurement of progesterone (P 4 ) in plasma of equine, bovine and rats are described. After extraction of plasma with diethylic ether the RIA methods were performed. The first one utilizes 125 I progesterone (double antibody method) and the other 1,2,6,7,16, 17 3 H progesterone (adsorption in charcoal/dextran). Both two methods were suitable in the valuation of plasma P 4 concentration in different physiological reproductive conditions. The method of the double antibody showed higher sensibility beyond to be less expensive than the other method. Despite it, the two RIA methods were much less expensive than available commercial Kits in the market. (author)

  2. Low plasma taurine concentration in Newfoundland dogs is associated with low plasma methionine and cyst(e)ine concentrations and low taurine synthesis.

    Science.gov (United States)

    Backus, Robert C; Ko, Kwang Suk; Fascetti, Andrea J; Kittleson, Mark D; Macdonald, Kristin A; Maggs, David J; Berg, John R; Rogers, Quinton R

    2006-10-01

    Although taurine is not dietarily essential for dogs, taurine deficiency and dilated cardiomyopathy (DCM) are sporadically reported in large-breed dogs. Taurine status and husbandry were examined in 216 privately owned Newfoundlands, a giant dog breed with high incidence of idiopathic DCM (1.3-2.5%). Plasma taurine concentration was positively correlated (P ine (r = 0.37) and methionine (r = 0.35) concentrations and was similar across age, sex, neutering status, body weight, and body-condition scores. Plasma taurine concentration was low (ine, tryptophan, and alpha-amino-n-butyric acid concentrations than the other dogs (P ine and blood glutathione, lower (P < 0.01) de novo taurine synthesis (59 +/- 15 vs. 124 +/- 27 mg x kg(-0.75) x d(-1)), and greater (P < 0.05) fecal bile acid excretion (1.7 +/- 0.2 vs. 1.4 +/- 0.2 micromol/g). Newfoundlands would appear to have a higher dietary sulfur amino acid requirement than Beagles, a model breed used in nutrient requirement determinations.

  3. A high sensitivity momentum flux measuring instrument for plasma thruster exhausts and diffusive plasmas.

    Science.gov (United States)

    West, Michael D; Charles, Christine; Boswell, Rod W

    2009-05-01

    A high sensitivity momentum flux measuring instrument based on a compound pendulum has been developed for use with electric propulsion devices and radio frequency driven plasmas. A laser displacement system, which builds upon techniques used by the materials science community for surface stress measurements, is used to measure with high sensitivity the displacement of a target plate placed in a plasma thruster exhaust. The instrument has been installed inside a vacuum chamber and calibrated via two different methods and is able to measure forces in the range of 0.02-0.5 mN with a resolution of 15 microN. Measurements have been made of the force produced from the cold gas flow and with a discharge ignited using argon propellant. The plasma is generated using a Helicon Double Layer Thruster prototype. The instrument target is placed about 1 mean free path for ion-neutral charge exchange collisions downstream of the thruster exit. At this position, the plasma consists of a low density ion beam (10%) and a much larger downstream component (90%). The results are in good agreement with those determined from the plasma parameters measured with diagnostic probes. Measurements at various flow rates show that variations in ion beam velocity and plasma density and the resulting momentum flux can be measured with this instrument. The instrument target is a simple, low cost device, and since the laser displacement system used is located outside the vacuum chamber, the measurement technique is free from radio frequency interference and thermal effects. It could be used to measure the thrust in the exhaust of other electric propulsion devices and the momentum flux of ion beams formed by expanding plasmas or fusion experiments.

  4. Toxic plasma concentration of ropivacaine after a paravertebral block in a patient suffering from severe hypoalbuminemia.

    Science.gov (United States)

    Calenda, Emile; Baste, Jean Marc; Hajjej, Ridha; Danielou, Eric; Peillon, Christophe

    2014-03-01

    A case of systemic ropivacaine toxicity from a continuous thoracic paravertebral block in an adult patient who received a lobectomy is presented. The catheter was placed by the surgeon. Eleven hours after the start of the infusion, the patient experienced an arrhythmia leading to death. The total venous plasma concentration of ropivacaine was high (3.2 μg/mL). Furthermore, the patient had severe hypoalbuminemia (albumin 24 g/L), which resulted in the increase of the unbound ropivacaine plasma concentration that was responsible for the toxic side effects. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Effects of Barium Concentration on Oropharyngeal Swallow Timing Measures

    OpenAIRE

    Stokely, Shauna L.; Molfenter, Sonja M.; Steele, Catriona M.

    2013-01-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between “thin” (40 % w/v concentration) and “ultrathin” (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; ...

  6. Variation of pH-measurement in platelet concentrates

    NARCIS (Netherlands)

    van der Meer, P. F.; van Zanten, A. P.; Pietersz, R. N.; Reesink, H. W.

    2001-01-01

    To measure pH in platelet concentrates, blood gas analysers with different calibration principles may be used. In this study, variances observed in pH measurements with two types of blood gas analysers were investigated. pH was measured in crystalloid solutions (platelet additive solution (PAS-II),

  7. Impact of gender and menstrual cycle phase on plasma cytokine concentrations.

    LENUS (Irish Health Repository)

    O'Brien, Sinead M

    2012-02-03

    OBJECTIVE: The lifetime prevalence of major depression is twice as high in females as in males. Depression is known to increase at periods where there are changes in gonadal hormones. We examined pro- and anti-inflammatory cytokine levels during the normal menstrual cycle of healthy females compared to similar time points in healthy males. METHODS: Plasma concentrations of interleukin (IL)-4, IL-6, IL-8, IL-10, tumour necrosis factor-alpha (TNF-alpha) and soluble IL-6 receptor (sIL-6R) were measured with enzyme-linked immunosorbent assays in healthy females during the normal ovulatory menstrual cycle and also in males at similar time points. RESULTS: The luteal phase of the menstrual cycle is associated with increased production of sIL-6R, IL-4 and TNF-alpha compared to the early follicular phase. No change was observed in IL-6, IL-8 and IL-10 concentration throughout the menstrual cycle. We found IL-4 positively correlated with oestrogen while TNF-alpha positively correlated with progesterone. Females were found to have significantly higher concentrations of TNF-alpha and sIL-6R across all phases of the menstrual cycle, compared to males across similar time points. CONCLUSION: The normal menstrual cycle is associated with increased production of sIL-6R, IL-4 and TNF-alpha in the luteal phase compared to the early follicular phase. Females have significantly higher concentrations of sIL-6R and TNF-alpha at all time points across the menstrual cycle than males.

  8. Prediagnostic circulating concentrations of plasma insulin-like growth factor-I and risk of lymphoma in the European Prospective Investigation into Cancer and Nutrition

    NARCIS (Netherlands)

    Perez-Cornago, Aurora; Appleby, Paul N.; Tipper, Sarah; Key, Timothy J.; Allen, Naomi E.; Nieters, Alexandra; Vermeulen, Roel; Roulland, Sandrine; Casabonne, Delphine; Kaaks, Rudolf; Fortner, Renee T.; Boeing, Heiner; Trichopoulou, Antonia; La Vecchia, Carlo; Klinaki, Eleni; Hansen, Louise; Tjønneland, Anne; Bonnet, Fabrice; Fagherazzi, Guy; Boutron-Ruault, Marie Christine; Pala, Valeria; Masala, Giovanna; Sacerdote, Carlotta; Peeters, Petra H.; Bueno-de-Mesquita, H. Bas; Weiderpass, Elisabete; Dorronsoro, Miren; Quirós, J. Ramón; Barricarte, Aurelio; Gavrila, Diana; Agudo, Antonio; Borgquist, Signe; Rosendahl, Ann H.; Melin, Beatrice; Wareham, Nick; Khaw, Kay Tee; Gunter, Marc; Riboli, Elio; Vineis, Paolo; Travis, Ruth C.

    2017-01-01

    Insulin-like growth factor (IGF)-I has cancer promoting activities. However, the hypothesis that circulating IGF-I concentration is related to risk of lymphoma overall or its subtypes has not been examined prospectively. IGF-I concentration was measured in pre-diagnostic plasma samples from a nested

  9. Effects of barium concentration on oropharyngeal swallow timing measures.

    Science.gov (United States)

    Stokely, Shauna L; Molfenter, Sonja M; Steele, Catriona M

    2014-02-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between "thin" (40 % w/v concentration) and "ultrathin" (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.

  10. Hemostatic variables, plasma lactate concentration, and inflammatory biomarkers in dogs with gastric dilatation-volvulus.

    Science.gov (United States)

    Verschoof, J; Moritz, A; Kramer, M; Bauer, N

    2015-01-01

    Prospective characterization of hemostastatic variables, plasma lactate concentration, and inflammatory biomarkers in dogs with gastric dilatation-volvulus (GDV). Coagulation variables (platelets, prothrombin time [PT], activated partial thromboplastin time [aPTT], fibrinogen, antithrombin [AT], protein C [PC], protein S [PS], D-dimers), plasma lactate concentration and inflammatory biomarkers (C-reactive protein, white blood cell [WBC] count, lymphocyte and neutrophil numbers) were assessed in 20 dogs with GDV presented between 2011 and 2012. Blood was taken preoperatively and at days 1 and 3 postoperatively. The prognostic value of these variables before and after surgery was evaluated as well as the behavior of variables during the study. Overall, 7/20 (35%) dogs did not survive; two dogs (29%) were euthanized during surgery due to severe gastric necrosis and 5 (71%) dogs after surgery due to sepsis and disseminated intravascular coagulopathy. Prior to surgery, median plasma lactate concentration was significantly (p = 0.01) lower in survivors (6.2 mmol/l, range 1.9-9.7 mmol/l) when compared to non-survivors (11.8 mmol/l, range 7.5-16.2 mmol/l). In dogs dying after surgery, significantly higher plasma lactate concentration, coagulation times and D-dimer concentration were present as well as lower fibrinogen concentration and activity of PC and AT compared to survivors. At discharge, activity of AT, PC and PS were markedly below the reference interval in 6/13 (46%), 11/13 (85%), and 8/13 (62%) dogs, respectively. Only lactate plasma concentration was of preoperative prognostic value. After surgery, severe abnormalities of coagulation variables, especially the endogenous anticoagulants were present in most of the dogs. The severity of the abnormalities was associated with survival.

  11. Correlations between plasma noradrenaline concentrations, antioxidants, and neutrophil counts after submaximal resistance exercise in men

    Science.gov (United States)

    Ramel, A; Wagner, K; Elmadfa, I

    2004-01-01

    Objectives: To investigate noradrenaline concentrations, neutrophil counts, plasma antioxidants, and lipid oxidation products before and after acute resistance exercise. Methods: 17 male participants undertook a submaximal resistance exercise circuit (10 exercises; 75% of the one repetition maximum; mean (SD) exercise time, 18.6 (1.1) minutes). Blood samples were taken before and immediately after exercise and analysed for plasma antioxidants, noradrenaline, neutrophils, and lipid oxidation products. Wilcoxon's signed-rank test and Pearson's correlation coefficient were used for calculations. Results: Neutrophils, noradrenaline, fat soluble antioxidants, and lipid oxidation products increased after exercise. Noradrenaline concentrations were associated with higher antioxidant concentrations. Neutrophils were related to higher concentrations of conjugated dienes. Conclusions: Submaximal resistance exercise increases plasma antioxidants. This might reflect enhanced antioxidant defence in response to the oxidative stress of exercise, though this is not efficient for inhibiting lipid oxidation. The correlation between noradrenaline concentrations and plasma antioxidants suggests a modulating role of the stress hormone. Neutrophils are a possible source of oxidative stress after resistance exercise. PMID:15388566

  12. Aquatic respiration rate measurements at low oxygen concentrations.

    Directory of Open Access Journals (Sweden)

    Moritz Holtappels

    Full Text Available Despite its huge ecological importance, microbial oxygen respiration in pelagic waters is little studied, primarily due to methodological difficulties. Respiration measurements are challenging because of the required high resolution of oxygen concentration measurements. Recent improvements in oxygen sensing techniques bear great potential to overcome these limitations. Here we compare 3 different methods to measure oxygen consumption rates at low oxygen concentrations, utilizing amperometric Clark type sensors (STOX, optical sensors (optodes, and mass spectrometry in combination with (18-18O2 labeling. Oxygen concentrations and consumption rates agreed well between the different methods when applied in the same experimental setting. Oxygen consumption rates between 30 and 400 nmol L(-1 h(-1 were measured with high precision and relative standard errors of less than 3%. Rate detection limits in the range of 1 nmol L(-1 h(-1 were suitable for rate determinations in open ocean water and were lowest at the lowest applied O2 concentration.

  13. Sleep restriction alters plasma endocannabinoids concentrations before but not after exercise in humans.

    Science.gov (United States)

    Cedernaes, Jonathan; Fanelli, Flaminia; Fazzini, Alessia; Pagotto, Uberto; Broman, Jan-Erik; Vogel, Heike; Dickson, Suzanne L; Schiöth, Helgi B; Benedict, Christian

    2016-12-01

    Following binding to cannabinoid receptors, endocannabinoids regulate a variety of central nervous system processes including appetite and mood. Recent evidence suggests that the systemic release of these lipid metabolites can be altered by acute exercise and that their levels also vary across the 24-h sleep-wake cycle. The present study utilized a within-subject design (involving 16 normal-weight men) to determine whether daytime circulating endocannabinoid concentrations differ following three nights of partial sleep deprivation (4.25-h sleep opportunity, 2:45-7a.m. each night) vs. normal sleep (8.5-h sleep opportunity, 10:30p.m.-7a.m. each night), before and after an acute bout of ergometer cycling in the morning. In addition, subjective hunger and stress were measured. Pre-exercise plasma concentrations of 2-arachidonoylglycerol (2AG) were 80% higher 1.5h after awakening (vs. normal sleep, pexercise (+44%, pexercise-induced rise. Finally, subjective stress was generally lower on the day after three nights of short sleep vs. normal sleep, especially after exercise (pexercise-induced elevations of endocannabinoids appear to be less affected by short sleep duration. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  14. Variation in absorption and half-life of hydrocortisone influence plasma cortisol concentrations.

    Science.gov (United States)

    Hindmarsh, Peter C; Charmandari, Evangelia

    2015-04-01

    Hydrocortisone therapy should be individualized in congenital adrenal hyperplasia (CAH) patients to avoid over and under replacement. We have assessed how differences in absorption and half-life of cortisol influence glucocorticoid exposure. Forty-eight patients (21 M) aged between 6·1 and 20·3 years with CAH due to CYP21A2 deficiency were studied. Each patient underwent a 24-h plasma cortisol profile with the morning dose used to calculate absorption parameters along with an intravenous (IV) hydrocortisone (15 mg/m(2) body surface area) bolus assessment of half-life. Parameters derived were maximum plasma concentration (Cmax ), time of maximum plasma concentration (tmax ), time to attaining plasma cortisol concentration cortisol. Mean half-life was 76·5 ± 5·2 (range 40-225·3) min, Cmax 780·7 ± 61·6 nmol/l and tmax 66·7 (range 20-118) min. Time taken to a plasma cortisol concentration less than 100 nmol/l was 289 (range 140-540) min. Those with a fast half-life and slow tmax took longest to reach a plasma cortisol concentration less than 100 nmol/l (380 ± 34·6 min), compared to those with a slow half-life and fast tmax (298 ± 34·8 min) and those with a fast half-life and fast tmax (249·5 ± 14·4 min) (One-way anovaF = 4·52; P = 0·009). Both rate of absorption and half-life of cortisol in the circulation play important roles in determining overall exposure to oral glucocorticoid. Dose regimens need to incorporate estimates of these parameters into determining the optimum dosing schedule for individuals. © 2014 John Wiley & Sons Ltd.

  15. Oestradiol-17β plasma concentrations after intramuscular injection of oestradiol benzoate or oestradiol cypionate in llamas (Lama glama

    Directory of Open Access Journals (Sweden)

    Aba Marcelo A

    2010-02-01

    Full Text Available Abstract Background Llamas (Lama glama are induced ovulators and the process of ovulation depends on dominant follicular size. In addition, a close relationship between behavioural estrus and ovulation is not registered in llamas. Therefore, the exogenous control of follicular development with hormones aims to predict the optimal time to mate. Oestradiol-17β (E2 and its esters are currently used in domestic species, including camelids, in synchronization treatments. But, in llamas, there is no reports regarding the appropriate dosages to be used and most protocols have been designed by extrapolation from those recommended for other ruminants. The aim of the present study was to characterize plasma E2 concentrations in intact female llamas following a single intramuscular (i.m. injection of two oestradiol esters: oestradiol benzoate (EB and oestradiol cypionate (ECP. Methods Twelve non pregnant and non lactating sexually mature llamas were i.m. injected on day 0 with 2.5 mg of EB (EB group, n = 6 or ECP (ECP group, n = 6. Blood samples were collected immediately before injection, at 1, 6, 12, 24 h after treatment and then daily until day 14 post injection. Changes in hormone concentrations with time were analyzed in each group by analysis of variance (ANOVA using a repeated measures (within-SS design. Plasma E2 concentrations and area under the concentration-time curve (AUC values were compared between groups by ANOVA. In all cases a Least-Significant Difference test (LSD was used to determine differences between means. Hormonal and AUC data are expressed as mean ± S.E.M. Results Peak plasma E2 concentrations were achieved earlier and were higher in EB group than in ECP group. Thereafter, E2 returned to physiological concentrations earlier in EB group (day 5 than in ECP group (day 9. Although plasma E2 profiles differed over time among groups there were no differences between them on AUC values. Conclusions The i.m. injection of a single dose

  16. Oestradiol-17β plasma concentrations after intramuscular injection of oestradiol benzoate or oestradiol cypionate in llamas (Lama glama)

    Science.gov (United States)

    2010-01-01

    Background Llamas (Lama glama) are induced ovulators and the process of ovulation depends on dominant follicular size. In addition, a close relationship between behavioural estrus and ovulation is not registered in llamas. Therefore, the exogenous control of follicular development with hormones aims to predict the optimal time to mate. Oestradiol-17β (E2) and its esters are currently used in domestic species, including camelids, in synchronization treatments. But, in llamas, there is no reports regarding the appropriate dosages to be used and most protocols have been designed by extrapolation from those recommended for other ruminants. The aim of the present study was to characterize plasma E2 concentrations in intact female llamas following a single intramuscular (i.m.) injection of two oestradiol esters: oestradiol benzoate (EB) and oestradiol cypionate (ECP). Methods Twelve non pregnant and non lactating sexually mature llamas were i.m. injected on day 0 with 2.5 mg of EB (EB group, n = 6) or ECP (ECP group, n = 6). Blood samples were collected immediately before injection, at 1, 6, 12, 24 h after treatment and then daily until day 14 post injection. Changes in hormone concentrations with time were analyzed in each group by analysis of variance (ANOVA) using a repeated measures (within-SS) design. Plasma E2 concentrations and area under the concentration-time curve (AUC) values were compared between groups by ANOVA. In all cases a Least-Significant Difference test (LSD) was used to determine differences between means. Hormonal and AUC data are expressed as mean ± S.E.M. Results Peak plasma E2 concentrations were achieved earlier and were higher in EB group than in ECP group. Thereafter, E2 returned to physiological concentrations earlier in EB group (day 5) than in ECP group (day 9). Although plasma E2 profiles differed over time among groups there were no differences between them on AUC values. Conclusions The i.m. injection of a single dose of both

  17. Measurement of radon activity concentrations in air of Tuzla city

    International Nuclear Information System (INIS)

    Adrovic, F.; Fazlic, R.; Tresnjo, Z.

    2004-01-01

    The survey was conducted over one year in the area of Tuzla city and its surrounding. At the measuring locations there were registered Daily and seasonal variations in outdoor radon concentration were observed, with average values lying within the region of 9 - 30 Bq/m 3 . The results of the measurements will be included in the concentration map of radon activity in Bosnia and Herzegovina, which is under preparation. (P.A.)

  18. Plasma and muscle cortisol measurements as indicators of meat quality and stress in pigs.

    Science.gov (United States)

    Shaw, F D; Trout, G R; McPhee, C P

    1995-01-01

    Post-slaughter blood samples and muscle samples were collected from pigs slaughtered at the completion of a live-animal performance trial. There were two lines of pigs in which the halothane allele (n) was segregating. The lines were a lean line selected for rapid lean growth and an unselected fat line. There were homozygous normal (NN), homozygous halothane positive (nn) and heterozygous (Nn) genotypes in both lnes. Cortisol was measured in the plasma of the blood samples and in muscle juice obtained by high-speed centrifugation. Meat quality was assessed using pH, colour, fibre-optic probe, drip loss and cure yield measurements. Plasma cortisol concentrations in the fat line were significantly (P meat quality attributes were generally highly significant (r = 0·31 to r = 0·51, P < 0·001) There was a highly significant correlation (r = 0·73, P < 0·0001) between plasma and muscle cortisol concentrations.

  19. Directional rf probe for measurement of conductivity of flowing plasmas

    International Nuclear Information System (INIS)

    Jayakumar, R.; Chakravarthy, D.P.; Rohatgi, V.K.

    1977-01-01

    An electrodeless immersible rf probe for measurement of plasma conductivity in the range 0.01 to 100 mho/m has been designed and fabricated. The probe, with an overall diameter of 11 mm, employs unidirectional electromagnetic field lines which reduce the inaccuracies caused by insertion of the probe in a flowing plasma. In the range studied the probe output shows a linear relationship with the conductivity of the medium. Such probes are of interest in the study of MHD and reentry plasmas

  20. Density measurements of microsecond-conduction-time POS plasmas

    International Nuclear Information System (INIS)

    Hinshelwood, D.; Goodrich, P.J.; Weber, B.V.; Commisso, R.J.; Grossmann, J.M.; Kellogg, J.C.

    1993-01-01

    Measurements of the electron density in a coaxial microsecond conduction time plasma opening switch during switch operation are described. Current conduction is observed to cause a radial redistribution of the switch plasma. A local reduction in axial line density of more than an order of magnitude occurs by the time opening begins. This reduction, and the scaling of conduction current with plasma density, indicate that current conduction in this experiment is limited by hydrodynamic effects. It is hypothesized that the density reduction allows the switch to open by an erosion mechanism. Initial numerical modeling efforts have reproduced the principal observed results. A model that predicts accurately the conduction current is presented

  1. Measurements of the neutron yield from a coaxial gun plasma

    International Nuclear Information System (INIS)

    Zolototrubov, I.M.; Krasnikov, A.A.; Kurishchenko, A.M.; Novikov, Yu.M.; Poryatuj, V.S.; Tolstolutskij, A.G.

    1977-01-01

    Neutron yield from deuterium plasma produced by a pulse coaxial accelerator was measured. The maximum neutron yield with 5 kj stored in a condenser battery is 3x10 6 neutron/pulse. The basis of the method of measuring neutron yield from the plasma was through the induced activity. It was shown that application of even a small uniform longitudinal magnetic field (up to 1 kOe) on the accelerator decreases several times the neutron yield. It is also shown that a small amount of stored discharge energy can produce high-temperature plasma at the output of pulse coaxial accelerator in the absense of the direct magnetic field. It is supposed that the reason for the reduction of neutron yield level in the case of applying the magnetic field is decreasing plasma density because of increasing the bunch cross-section

  2. Plasma density measurements from the GEOS-1 relaxation sounder

    International Nuclear Information System (INIS)

    Etcheto, J.; Bloch, J.J.

    1978-01-01

    The relaxation sounder uses the characteristics of the propagation of radiowaves to sound the plasma surrounding the spacecraft. It determines, in particular, the plasma frequency, which gives the electron density. Measurements over the whole dayside of the magnetosphere, from the evening to the night sectors, are now available. The behaviour of the plasma resonance depends on local time, the nighttime echoes being generally weaker. Density measurements thus obtained are shown and discussed in the context of what is presently known about the plasma distribution in the magnetosphere. In particular, the density around apogee is studied as a function of magnetic activity. On the dayside, it appears to vary between a few and a few tens of electrons per cubic centimeter. The evolution of the density profile for several consecutive days is studied and interpreted tracing back the drift of the particles. (Auth.)

  3. Opacity measurements in shock-generated argon plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Erskine, D.

    1993-07-01

    Dense plasmas having uniform and constant density and temperature are generated by passage of a planar shock wave through gas. The opacity of the plasma is accurately measured versus wavelength by recording the risetime of emitted light. This technique is applicable to a wide variety of species and plasma conditions. Initial experiments in argon have produced plasmas with 2 eV temperatures, 0.004--0.04 g/cm{sup 3} densities, and coupling parameters {Gamma} {approximately}0.3--0.7. Measurements in visible light are compared with calculations using the HOPE code. An interesting peak in the capacity at 400 nm is observed for the first time and is identified with the 4s-5p transition in excited neutral argon atoms.

  4. Temperature Measurements of Dense Plasmas by Detailed Balance

    International Nuclear Information System (INIS)

    Holl, A; Redmer, R; Ropke, G; Reinholz, H; Thiele, R; Fortmann, C; Forster, E; Cao, L; Tschentscher, T; Toleikis, S; Glenzer, S H

    2006-01-01

    Plasmas at high electron densities of n e = 10 20 - 10 26 cm -3 and moderate temperatures T e = 1 - 20 eV are important for laboratory astrophysics, high energy density science and inertial confinement fusion. These plasmas are usually referred to as Warm Dense Matter (WDM) and are characterized by a coupling parameter of Λ ∼> 1 where correlations become important. The characterization of such plasmas is still a challenging task due to the lack of direct measurement techniques for temperatures and densities. They propose to measure the Thomson scattering spectrum of vacuum-UV radiation off density fluctuations in the plasma. Collective Thomson scattering provides accurate data for the electron temperature applying first principles. Further, this method takes advantage of the spectral asymmetry resulting from detailed balance and is independent of collisional effects in these dense systems

  5. Serum creatinine and creatinine clearance for predicting plasma methotrexate concentrations after high-dose methotrexate chemotherapy for the treatment for childhood lymphoblastic malignancies.

    Science.gov (United States)

    Xu, Wei-qun; Zhang, Ling-yan; Chen, Xue-ying; Pan, Bin-hua; Mao, Jun-qing; Song, Hua; Li, Jing-yuang; Tang, Yong-min

    2014-01-01

    Monitoring of plasma methotrexate (MTX) concentrations allows for therapeutic adjustments in treating childhood acute lymphoblastic leukemia (ALL) or non-Hodgkin lymphoma (NHL) with high-dose MTX (HDMTX). We tested the hypothesis that assessment of creatinine clearance (CrCl) and/or serum Cr may be a suitable means of monitoring plasma MTX concentrations. All children in the study had ALL or NHL, were in complete remission, and received HDMTX (3 or 5 g/m(2))+leucovorin. Plasma MTX concentrations were measured at 24, 48, and 96 h. CrCl was determined at 24 and 48 h. Correlations between 24- and 48-h plasma MTX concentrations and CrCl and serum Cr concentrations were determined. CrCl and serum Cr concentrations were compared over time between children who had delayed and non-delayed MTX elimination. A total of 105 children were included. There were significant negative correlations between CrCl at 24 and 48 h and plasma MTX concentrations at 24 (both p < 0.001) and 48 h (both p < 0.001). There were significant positive correlations between serum Cr concentrations at both 24 and 48 h and plasma MTX concentrations at 24 (both p < 0.001) and 48 h (both p < 0.001). There were 88 (30.2 %) instances of elimination delay. Children with elimination delay had significantly lower CrCl and higher Cr concentrations at 24 and 48 h compared with children without elimination delay (all p < 0.05). Our findings suggest that, with further refinement, assessment of renal function may be a useful means of monitoring plasma MTX concentrations during HDMTX for ALL and NHL.

  6. Relationship between plasma dabigatran concentration and activated partial thromboplastin time in Japanese patients with non-valvular atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Daiki Shimomura

    2015-08-01

    Conclusions: There was a significant correlation between plasma dabigatran concentrations and aPTT. Additionally, in daily clinical practice in Japan, plasma dabigatran concentrations and aPTT reached a peak in the 4-h post administration range. Considering the pharmacokinetics of dabigatran, aPTT can be used as an index for risk screening for excess dabigatran concentrations in Japanese patients with NVAF.

  7. Effects of Electronic Cigarette Liquid Nicotine Concentration on Plasma Nicotine and Puff Topography in Tobacco Cigarette Smokers: A Preliminary Report.

    Science.gov (United States)

    Lopez, Alexa A; Hiler, Marzena M; Soule, Eric K; Ramôa, Carolina P; Karaoghlanian, Nareg V; Lipato, Thokozeni; Breland, Alison B; Shihadeh, Alan L; Eissenberg, Thomas

    2016-05-01

    Electronic cigarettes (ECIGs) aerosolize a liquid that usually contains propylene glycol and/or vegetable glycerin, flavorants, and the dependence-producing drug nicotine in various concentrations. This study examined the extent to which ECIG liquid nicotine concentration is related to user plasma nicotine concentration in ECIG-naïve tobacco cigarette smokers. Sixteen ECIG-naïve cigarette smokers completed four laboratory sessions that differed by the nicotine concentration of the liquid (0, 8, 18, or 36 mg/ml) that was placed into a 1.5 Ohm, dual coil "cartomizer" powered by a 3.3V battery. In each session, participants completed two, 10-puff ECIG use bouts with a 30-second inter-puff interval; bouts were separated by 60 minutes. Venous blood was sampled before and after bouts for later analysis of plasma nicotine concentration; puff duration, volume, and average flow rate were measured during each bout. In bout 1, relative to the 0mg/ml nicotine condition (mean = 3.8 ng/ml, SD = 3.3), plasma nicotine concentration increased significantly immediately after the bout for the 8 (mean = 8.8 ng/ml, SD = 6.3), 18 (mean = 13.2 ng/ml, SD = 13.2), and 36 mg/ml (mean = 17.0 ng/ml, SD = 17.9) liquid concentration. A similar pattern was observed after bout 2. Average puff duration in the 36 mg/ml condition was significantly shorter compared to the 0mg/ml nicotine condition. Puff volume increased during the second bout for 8 and 18 mg/ml conditions. For a given ECIG device, nicotine delivery may be directly related to liquid concentration. ECIG-naïve cigarette smokers can, from their first use bout, attain cigarette-like nicotine delivery profiles with some currently available ECIG products. Liquid nicotine concentration can influence plasma nicotine concentration in ECIG-naïve cigarette smokers, and, at some concentrations, the nicotine delivery profile of a 3.3V ECIG with a dual coil, 1.5-Ohm cartomizer approaches that of a combustible tobacco cigarette in this

  8. Measurements of indoor radon concentration in Libyan cities

    International Nuclear Information System (INIS)

    Elarabiy, S. F.; Khalifa, M.; Misrati, N.; Chahboune, N.; Ahmed, M.

    2012-12-01

    Studies confirm that the risk of exposure to indor radon is attributable to lung cancer worldwide. The relationship between radon exposure and cancer is a linear one which necessitates for need for measurements of indoor radon concentration. This paper presents the results of measurements of indoor radon in several libya cities using CR-39 plastic. The results showed that the average radon concentration in the cities of Tripoli, Al-harcha and Alrajaban were 48.8 Bg/m 3 , 51.4 Bg/m 3 and 55.5 Bg/m 3 respectively. The average indoor radon concentration in Libya is low comparing with other studies. (Author)

  9. Analysis of BAG3 plasma concentrations in patients with acutely decompensated heart failure.

    Science.gov (United States)

    Gandhi, Parul U; Gaggin, Hanna K; Belcher, Arianna M; Harisiades, Jamie E; Basile, Anna; Falco, Antonia; Rosati, Alessandra; Piscione, Federico; Januzzi, James L; Turco, M Caterina

    2015-05-20

    BCL-2-associated athanogene 3 (BAG3) is a protein implicated in the cardiomyocyte stress response and genesis of cardiomyopathy. Extracellular BAG3 is measurable in patients with heart failure (HF), but the relationship of BAG3 with HF prognosis is unclear. BAG3 plasma concentrations were measured in 39 acutely decompensated HF patients; the primary endpoint was death at 1 year. Baseline characteristics were compared by vital status and median BAG3 concentration. Correlation of BAG3 with left ventricular ejection fraction (LVEF) and other biomarkers was performed. Prognostic value was assessed using Cox proportional hazards regression and Kaplan-Meier analysis. At baseline, median BAG3 was significantly higher in decedents (N=11) than survivors (N=28; 1489 ng/mL versus 50 ng/mL; P=0.04); decedents also had worse renal function and higher median natriuretic peptide (NP) and sST2. BAG3 was not significantly correlated with NPs, mid-regional pro-adrenomedullin, sST2, or eGFR, however. Mortality was increased in patients with supra-median BAG3 (>336 ng/mL; 42.1% versus 15.0%, P=0.06). In age and LVEF-adjusted Cox proportional hazards, BAG3 remained a significant mortality predictor (HR=3.20; 95% CI=1.34-7.65; P=0.02); those with supra-median BAG3 had significantly shorter time-to-death (P=0.04). The stress response protein BAG3 is measurable in patients with ADHF and may be prognostic for death. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Workplace aerosol mass concentration measurement using optical particle counters.

    Science.gov (United States)

    Görner, Peter; Simon, Xavier; Bémer, Denis; Lidén, Göran

    2012-02-01

    Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM® 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO®) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions

  11. Plasma drug concentrations and clinical effects of a peripheral alpha-2-adrenoceptor antagonist, MK-467, in horses sedated with detomidine.

    Science.gov (United States)

    Vainionpää, Mari H; Raekallio, Marja R; Pakkanen, Soile A E; Ranta-Panula, Ville; Rinne, Valtteri M; Scheinin, Mika; Vainio, Outi M

    2013-05-01

    To investigate plasma drug concentrations and the effect of MK-467 (L-659'066) on sedation, heart rate and gut motility in horses sedated with intravenous (IV) detomidine. Experimental randomized blinded crossover study. Six healthy horses. Detomidine (10 μg kg(-1) IV) was administered alone (DET) and in combination with MK-467 (250 μg kg(-1) IV; DET + MK). The level of sedation and intestinal sounds were scored. Heart rate (HR) and central venous pressure (CVP) were measured. Blood was collected to determine plasma drug concentrations. Repeated measures anova was used for HR, CVP and intestinal sounds, and the Student's t-test for pairwise comparisons between treatments for the area under the time-sedation curve (AUCsed ) and pharmacokinetic parameters. Significance was set at p Detomidine-induced intestinal hypomotility was prevented by MK-467. AUCsed was significantly higher with DET than DET + MK, but maximal sedations scores did not differ significantly between treatments. MK-467 lowered the AUC of the plasma concentration of detomidine, and increased its volume of distribution and clearance. MK-467 prevented detomidine induced bradycardia and intestinal hypomotility. MK-467 did not affect the clinical quality of detomidine-induced sedation, but the duration of the effect was reduced, which may have been caused by the effects of MK-467 on the plasma concentration of detomidine. MK-467 may be useful clinically in the prevention of certain peripheral side effects of detomidine in horses. © 2013 The Authors. Veterinary Anaesthesia and Analgesia © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  12. A small spacecraft for multipoint measurement of ionospheric plasma

    Science.gov (United States)

    Roberts, T. M.; Lynch, K. A.; Clayton, R. E.; Weiss, J.; Hampton, D. L.

    2017-07-01

    Measurement of ionospheric plasma is often performed by a single in situ device or remotely using cameras and radar. This article describes a small, low-resource, deployed spacecraft used as part of a local, multipoint measurement network. A B-field aligned sounding rocket ejects four of these spin-stabilized spacecraft in a cross pattern. In this application, each spacecraft carries two retarding potential analyzers which are used to determine plasma density, flow, and ion temperature. An inertial measurement unit and a light-emitting diode array are used to determine the position and orientation of the devices after deployment. The design of this spacecraft is first described, and then results from a recent test flight are discussed. This flight demonstrated the successful operation of the deployment mechanism and telemetry systems, provided some preliminary plasma measurements in a simple mid-latitude environment, and revealed several design issues.

  13. Dissociation between plasma concentrations of thyroxine and insulin-like growth factor-I.

    Science.gov (United States)

    Dauncey, M J; Morovat, A; Rudd, B T; Shakespear, R A

    1990-09-01

    The relation between plasma concentrations of thyroxine (T4) and insulin-like growth factor-I (IGF-I) has been examined in young, growing pigs under controlled conditions of energy intake. Compared with euthyroid controls, plasma levels of IGF-I were significantly elevated (P less than 0.005) both in hypothyroid animals on the same food intake and in hyperthyroid animals on double the food intake. There was however no increase in IGF-I in a hyperthyroid group on the control level of intake. Contrary to previous reports in which energy intake was not controlled, it is concluded that there is no simple correlation between plasma concentrations of T4 and IGF-I.

  14. Validation of image cytometry for sperm concentration measurement

    DEFF Research Database (Denmark)

    Egeberg Palme, Dorte L.; Johannsen, Trine Holm; Petersen, Jørgen Holm

    2017-01-01

    Sperm concentration is an essential parameter in the diagnostic evaluation of men from infertile couples. It is usually determined by manual counting using a hemocytometer, and is therefore both laborious and subjective. We have earlier shown that a newly developed image cytometry (IC) method may...... be used to determine sperm concentration. Here we present a validation of the IC method by analysis of 4010 semen samples. There was high agreement between IC and manual counting at sperm concentrations above 3 mill/ml and in samples with concentrations above 12 mill/ml the two methods can be used...... a lower coefficient of variation than the manual method (5% vs 10%), indicating a better precision of the IC method. In conclusion, measurement of sperm concentration by IC can be used at concentrations above 3 mill/ml and seems more accurate and precise than manual counting, making it an attractive...

  15. Traceable measurements of the activity concentration in air

    CERN Document Server

    Paul, A; Forkel-Wirth, Doris; Müller, A; Marcos, A

    2002-01-01

    The nuclear reactions induced by high energetic protons in heavy targets such as UC/sub 2/ and ThC cause a particular, complex radiation protection task at facilities like ISOLDE: the measurement of a mixture of different isotopes of the radioactive noble gas radon and the radon progenies in air. The knowledge of their respective activity concentration is fundamental for exposure assessments. Due to the complex mixture of activity concentrations in air, its precise determination is quite difficult. Therefore, a new procedure for taking reference samples was developed and implemented for the traceable measurement of the activity concentration of radioactive ions (e.g., radon progenies) in air. This technique is combined by measuring alpha -particles with a multi-wire ionization chamber for the parallel on-line determination of the activity concentration of different radon isotopes. (10 refs).

  16. Intercomparison of different instruments for measuring radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Iida, Takao

    1990-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap method, a flow-type ionization chamber (pulse-counting method), a two-filter method, an electrostatic collection method and a passive integration radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq·m -3 (in outdoor air) to 110 Bq·m -3 (in indoor air). The results obtained by these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling method was about 52% of radon concentration. (author)

  17. Intercomparison of different instruments that measure radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, M.; Iida, T.; Ikebe, Y.

    1987-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap technique, a flow-type ionization chamber (pulse-counting technique), a two-filter method, an electrostatic collection method and a passive integrating radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq/m/sup 3/ (in outdoor air) to 110 Bq/m/sup 3/ (in indoor air). The results obtained from these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling technique was about 52% of radon concentrations

  18. Traceable measurements of the activity concentration in air

    International Nuclear Information System (INIS)

    Paul, Annette; Honig, Anja; Forkel-Wirth, Doris; Mueller, Andre; Marcos, Alicia

    2002-01-01

    The nuclear reactions induced by high energetic protons in heavy targets such as UC 2 and ThC cause a particular, complex radiation protection task at facilities like ISOLDE: the measurement of a mixture of different isotopes of the radioactive noble gas radon and the radon progenies in air. The knowledge of their respective activity concentration is fundamental for exposure assessments. Due to the complex mixture of activity concentrations in air, its precise determination is quite difficult. Therefore, a new procedure for taking reference samples was developed and implemented for the traceable measurement of the activity concentration of radioactive ions (e.g., radon progenies) in air. This technique is combined by measuring α-particles with a multi-wire ionization chamber for the parallel on-line determination of the activity concentration of different radon isotopes

  19. Association of plasma PCB levels and HbA1c concentration in Iran.

    Science.gov (United States)

    Eftekhari, Sahar; Aminian, Omid; Moinfar, Zeinab; Schettgen, Thomas; Kaifie, Andrea; Felten, Michael; Kraus, Thomas; Esser, André

    2018-01-01

    The rapid increase in prevalence of diabetes mellitus over the last decades warrants more attention to the effects of environmental and occupational exposures on glucose metabolism. Our study aimed to assess the association between the plasma levels of various congeners of polychlorinated biphenyls (PCBs) and the serum concentration of glycated haemoglobin (HbA1c). Our study population consisted of 140 Iranian adults from seven different occupational groups and a group of non-occupationally exposed female participants. The plasma concentration of PCBs were determined at the laboratory of occupational toxicology at RWTH Aachen University, Germany. We considered an HbA1c concentration of 5.7% and more as indicating a disturbed glucose metabolism. Logistic regression was used to assess the association between quartiles of concentrations of PCB congeners and serum HbA1c. Participants with an increased HbA1c value had higher plasma levels of PCB 138, 153, 180 and the PCB sum, although this association was statistically not significant. There was no significant difference between the levels of PCB 138, 153, 180, the sum of these congeners, and PCB 118 in their quartiles when comparing with HbA1c concentrations. For our cohort, we could not demonstrate a significant association between PCB and HbA1c concentrations indicating a disturbance of glucose metabolism.

  20. [Relation between dose, plasma concentration and therapeutic effect of theophylline in children with sleep apnea].

    Science.gov (United States)

    Rodríguez-Palomares, C; Ugartechea, J C; Palma-Aguirre, J A; Juárez-Olguín, H; Calderón-Mandujano, B

    1989-12-01

    The plasma concentration of theophylline was determined in twelve children with infantile sleep apnea (average age 48.5 days). The purpose of the study was to correlate concentrations with the dosages given, the therapeutic response and any adverse effects which could arise. In addition, other pharmacokinetic values were found, half-life (t 1/2) and clearance concentrations (Clss). The oral maintenance dose used was 4 mg/kg/24 h. The serum concentration of theophylline was determined by a homogeneous immunoassay enzyme technique (EMIT). A bad correlation was found (r = 0.45) between the oral dosage given and the plasma concentrations found. This was probably due to variations in the clearance of the drug. Yet, plasma concentrations fell between 3.0 and 12.6 micrograms/mL, enough to satisfactorily control apneic episodes in all the children included in the study without undesirable side-effects. Only one patient had some trouble in falling asleep and showed signs of irritability. The half-life was 13.30 +/- 7.46 hours and Clss was 36.64 +/- 12.98 mL/h/kg. In general, our results correlate with those reported in the literature. The accuracy of the pharmacokinetic parameters with two samples is reliable, therefore avoiding the use of multiple sampling in this group of children.

  1. Low Plasma alpha-Tocopherol Concentrations and Adverse Clinical Outcomes in Diabetic Hemodialysis Patients

    NARCIS (Netherlands)

    Espe, K.M.; Raila, J.; Henze, A.; Blouin, K.; Schneider, A.; Schmiedeke, D.; Krane, V.; Pilz, S.; Schweigert, F.J.; Hocher, B.; Wanner, C.; Drechsler, C.

    2013-01-01

    Background and objectives Trials with the antioxidant vitamin E have failed to show benefit in the general population. Considering the different causes of death in ESRD, this study investigated the association between plasma concentrations of α-tocopherol and specific clinical outcomes in diabetic

  2. Effect of abomasal glucose infusion on plasma concentrations of gut peptides in periparturient dairy cows

    DEFF Research Database (Denmark)

    Larsen, Mogens; Relling, A E; Reynolds, C K

    2010-01-01

    Six Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in the portal vein, hepatic vein, mesenteric vein, and an artery were used to study the effects of abomasal glucose infusion on splanchnic plasma concentrations of gut peptides. The experimental design was a randomi...

  3. Phenylbutyrate reduces plasma leucine concentrations without affecting the flux of leucine

    Science.gov (United States)

    Phenylbutyrate (PB) has been used as an alternative pathway to excrete nitrogen in urea cycle disorder patients for the last 20 years. PB, after oxidation to phenylacetate, is conjugated with glutamine and excreted in the urine. A reduction in the plasma concentration of branched amino acids (BCAA) ...

  4. Calcium alpha-ketoglutarate administration to malnourished hemodialysis patients improves plasma arginine concentrations.

    Science.gov (United States)

    Riedel, E; Hampl, H; Steudle, V; Nündel, M

    1996-01-01

    Calcium alpha-ketoglutarate administration to 24 malnourished hemodialysis patients for 1 year leads to a significant increase in plasma concentrations of L-arginine from 53.6 +/- 18.3 (compared to a healthy control group: 87.5 +/- 27.3) to 71.1 +/- 15.9 mumol/l (p calcium alpha-ketoglutarate administration.

  5. Safflower oil consumption does not increase plasma conjugated linoleic acid concentrations in humans.

    Science.gov (United States)

    Herbel, B K; McGuire, M K; McGuire, M A; Shultz, T D

    1998-02-01

    Conjugated linoleic acid (CLA) is a mixture of positional and geometric isomers of linoleic acid (LA) with conjugated double bonds. CLA has anticarcinogenic properties and has been identified in human tissues, dairy products, meats, and certain vegetable oils. A variety of animal products are good sources of CLA, but plant oils contain much less. However, plant oils are a rich source of LA, which may be isomerized to CLA by intestinal microorganisms in humans. To investigate the effect of triacylglycerol-esterified LA consumption on plasma concentrations of esterified CLA in total lipids, a dietary intervention (6 wk) was conducted with six men and six women. During the intervention period a salad dressing containing 21 g safflower oil providing 16 g LA/d was added to the subjects' daily diets. Three-day diet records and fasting blood were obtained initially and during dietary and postdietary intervention periods. Although LA intake increased significantly during the dietary intervention, plasma CLA concentrations were not affected. Plasma total cholesterol and LDL-cholesterol concentrations were significantly lower after addition of safflower oil to the diet. In summary, consumption of triacylglycerol-esterified LA in safflower oil did not increase plasma concentrations of esterified CLA in total lipids.

  6. High fetal plasma adenosine concentration: a role for the fetus in preeclampsia?

    LENUS (Irish Health Repository)

    Espinoza, Jimmy

    2012-02-01

    OBJECTIVE: Clinical observations suggest a role for the fetus in the maternal manifestations of preeclampsia, but the possible signaling mechanisms remain unclear. This study compares the fetal plasma concentrations of adenosine from normal pregnancies with those from preeclampsia. STUDY DESIGN: This secondary data analysis included normal pregnancies (n = 27) and patients with preeclampsia (n = 39). Patients with preeclampsia were subclassified into patients with (n = 25) and without (n = 14) abnormal uterine artery Doppler velocimetry (UADV). RESULTS: Fetal plasma concentrations of adenosine were significantly higher in patients with preeclampsia (1.35 +\\/- 0.09 mumol\\/L) than in normal pregnancies (0.52 +\\/- 0.06 mumol\\/L; P < .0001). Fetal plasma concentrations of adenosine in patients with preeclampsia with abnormal UADV (1.78 +\\/- 0.15 mumol\\/L), but not with normal UADV (0.58 +\\/- 0.14 mumol\\/L), were significantly higher than in normal pregnancies (P < .0001). CONCLUSION: Patients with preeclampsia with sonographic evidence of chronic uteroplacental ischemia have high fetal plasma concentrations of adenosine.

  7. Decreased coenzyme Q10 concentration in plasma of children with cystic fibrosis

    NARCIS (Netherlands)

    Oudshoorn, J.H.; Lecluse, A.L.Y.; Berg, R. van den; Vaes, W.H.J.; Laag, J. van der; Houwen, R.H.J.

    2006-01-01

    OBJECTIVES: Coenzyme Q10 (CoQ10) is an effective lipophilic antioxidant and protects against lipid peroxidation by scavenging radicals. Patients with cystic fibrosis generally have fat malabsorption; thus, we hypothesized that overall plasma CoQ10 concentration in pediatric patients with cystic

  8. Plasma paracetamol concentrations and pharmacokinetics following rectal administration in neonates and young infants

    DEFF Research Database (Denmark)

    Hansen, Tom Giedsing; O'Brien, K; Morton, N S

    1999-01-01

    Despite widespread use in children pharmacokinetic data about paracetamol are relatively scarce, not the least in the youngest age groups. This study aimed to describe plasma paracetamol concentrations and pharmacokinetics of a single rectal paracetamol dose in neonates and young infants....

  9. Persistent increase of plasma butyryl/isobutyrylcarnitine concentrations as marker of SCAD defect and ethylmalonic encephalopathy

    DEFF Research Database (Denmark)

    Merinero, B; Perez-Cerda, C; Ruiz Sala, P

    2007-01-01

    High concentrations of butyryl/isobutyrylcarnitine (C(4)-carnitine) in plasma with increase of ethylmalonic acid (EMA) in urine point to different genetic entities, and further investigations are required to differentiate the possible underlying defect. Here we report three unrelated cases, two n...

  10. Evaluation of pulsatile plasma concentrations of growth hormone in healthy dogs and dogs with dilated cardiomyopathy

    NARCIS (Netherlands)

    Beijerink, N.J.; Lee, W.M.; Stokhof, A.A.; Voorhout, G.; Mol, J.A.; Kooistra, H.S.

    2011-01-01

    Abstract OBJECTIVE: To evaluate plasma concentrations of growth hormone (GH) and insulin-like growth factor I (IGF-I) in healthy dogs and large-breed dogs with dilated cardiomyopathy (DCM). ANIMALS: 8 dogs with DCM and 8 healthy control dogs of comparable age and body weight. PROCEDURES: Blood

  11. Heterogeneity at the CETP gene locus. Influence on plasma CETP concentrations and HDL cholesterol levels

    NARCIS (Netherlands)

    Kuivenhoven, J.A.; de Knijff, P.; Boer, J M; Smalheer, H A; Botma, G.J.; Seidell, J C; Kastelein, J.J.; Pritchard, P H

    This study was designed to investigate the association(s) between heterogeneity at the cholesteryl ester transfer protein (CETP) gene locus, CETP plasma concentrations, and HDL cholesterol levels. Healthy men with the lowest, median, and highest deciles of HDL cholesterol were selected from a large

  12. A twin study of the trough plasma steady-state concentration of metformin

    DEFF Research Database (Denmark)

    Stage, Tore B; Damkier, Per; Pedersen, Rasmus S

    2015-01-01

    OBJECTIVE: The aim of this study was to determine the intrapair similarity in trough steady-state plasma concentrations of metformin in monozygotic and dizygotic twin pairs. METHODS: We included 16 twin pairs (eight monozygotic and eight dizygotic twin pairs) for this study after contacting 524 t...

  13. Plasma urea nitrogen and progesterone concentrations and follicular dynamics in ewes fed proteins of different degradability

    Directory of Open Access Journals (Sweden)

    Gustavo Bianchi Lazarin

    2012-07-01

    Full Text Available The effects of overfeeding with protein of different degradability on body condition, plasma urea nitrogen and progesterone concentrations, ovulation number and follicular dynamics were assessed in Santa Ines ewes. Twelve ewes were assigned to a randomized block design according to body weight and received overfeeding with soybean meal or with corn gluten meal or maintenance diet for 28 days before ovulation and during the next estrous cycle. Blood samples were taken on days 7, 14, 21, and 28 after the beginning of treatments for analysis of plasma urea nitrogen and on days 3, 6, 9, 12, and 15 into the estrous cycle for analysis of plasma urea nitrogen and progesterone. Follicular dynamics was monitored daily by ultrasound during one estrous cycle. Dry matter and crude protein intake, weight gain, plasma urea nitrogen concentration before ovulation, number of ovulations, diameter of the largest follicle of the 1st and of the 2nd waves and the growth rate of the largest follicle of the 1st wave were higher in the ewes that received overfeeding. The growth rate of the largest follicle of the 3rd wave was higher in the ewes fed maintenance diet. The back fat thickness, plasma urea nitrogen before ovulation and progesterone concentrations, diameter of the largest follicle of the 2nd wave and growth rate of the largest follicle of the 3rd wave were higher in ewes that received overfeeding with soybean meal. The growth rate of the largest follicle of the 1st wave was higher in ewes that received overfeeding with corn gluten meal. Overfeeding with protein-rich feeds may increase the ovulation number and with soybean meal, it may be effective in increasing plasma progesterone concentration in ewes.

  14. Predictors of Per- and Polyfluoroalkyl Substance (PFAS) Plasma Concentrations in 6-10 Year Old American Children.

    Science.gov (United States)

    Harris, Maria H; Rifas-Shiman, Sheryl L; Calafat, Antonia M; Ye, Xiaoyun; Mora, Ana Maria; Webster, Thomas F; Oken, Emily; Sagiv, Sharon K

    2017-05-02

    Certain per- and polyfluoroalkyl substances (PFASs) are suspected developmental toxicants, but data on PFAS concentrations and exposure routes in children are limited. We measured plasma PFASs in children aged 6-10 years from the Boston-area Project Viva prebirth cohort, and used multivariable linear regression to estimate associations with sociodemographic, behavioral, and health-related factors, and maternal PFASs measured during pregnancy. PFAS concentrations in Project Viva children (sampled 2007-2010) were similar to concentrations among youth participants (aged 12-19 years) in the 2007-8 and 2009-10 National Health and Nutrition Examination Survey (NHANES); mean concentrations of most PFASs declined from 2007 to 2010 in Project Viva and NHANES. In mutually adjusted models, predictors of higher PFAS concentrations included older child age, lower adiposity, carpeting or a rug in the child's bedroom, higher maternal education, and higher neighborhood income. Concentrations of perfluorooctanesulfonate (PFOS), perfluorooctanoate (PFOA), perfluorohexanesulfonate (PFHxS), and 2-(N-methyl-perfluorooctane sulfonamido) acetate (Me-PFOSA-AcOH) were 26-36% lower in children of black mothers compared to children of white mothers and increased 12-21% per interquartile range increase in maternal pregnancy PFASs. Breastfeeding duration did not predict childhood PFAS concentrations in adjusted multivariable models. Together, the studied predictors explained the observed variability in PFAS concentrations to only a modest degree.

  15. Maternal plasma pyridoxal-5'-phosphate concentrations and risk of isolated oral clefts in the Philippines.

    Science.gov (United States)

    Tamura, Tsunenobu; Munger, Ronald G; Nepomuceno, Buena; Corcoran, Christopher; Cembrano, Joselito; Solon, Florentino

    2007-04-01

    We report that inadequate vitamin B-6 status of Filipino mothers, assessed by erythrocyte aspartate aminotransferase activity coefficient (EAST-AC), is associated with an increased risk for isolated cleft lip with or without cleft palate (CL/P) in their children. Its association with the status assessed by plasma pyridoxal-5'-phosphate (PLP) concentrations is unknown. In a case-control study in the Philippines including 46 cases (mothers of a child with CL/P) and 392 controls (mothers of an unaffected child), we evaluated the association between the risk for CL/P and maternal vitamin B-6 status assessed by PLP and EAST-AC. The ORs of CL/P were estimated by classifying mothers by PLP (>30, 20-30, and values, compared to those with adequate status by both values. Inadequate vitamin B-6 status assessed by maternal PLP and EAST-AC values independently and both combined was associated with an increased risk for CL/P. The association was highest when both values were considered, suggesting that the measurement of both PLP and EAST-AC provides better assessment of vitamin B-6 status than either measurement alone.

  16. Effects of Acute Supramaximal Cycle Exercise on Plasma FFA Concentration in Obese Adolescent Boys.

    Directory of Open Access Journals (Sweden)

    Georges Jabbour

    Full Text Available The aims of the present study are 1 to evaluate the free fatty acid (FFA profile and 2 to determine the relative anaerobic and aerobic contributions to total energy consumption during repeated supramaximal cycling bouts (SCE in adolescent boys with different body weight statuses.Normal-weight (NW, overweight (OW, and obese (OB adolescent boys (n =15 per group completed a SCE sessions consisted of 6 x 6s maximal sprints with 2 min of passive rest between each repetition. Plasma FFA levels were determined at rest, immediately after a 10 min warm-up, and immediately at the end of SCE. The anaerobic and aerobic contributions (% were measured via repeated SCE bouts. Insulin resistance was calculated using the homoeostatic model assessment (HOMA-IR index.The FFA concentrations measured immediately after SCE were higher in the OB group than in the OW and NW (p<0.01 and p<0.01, respectively groups. Moreover, the anaerobic contributions to SCE were significantly lower in obese adolescents (p<0.01 and decreased significantly during the 2nd, 3rd and 4th repetitions. The FFA levels were significantly associated with the HOMA-IR index and aerobic contribution among adolescent boys (r=0.83 and r=0.91, respectively, p<0.01.In contrast to the NW and OW groups, there is an increase in lipid mobilization and sift to aerobic energy metabolism during SCE in the OB group.

  17. Measurements of the sheath potential in low density plasmas

    International Nuclear Information System (INIS)

    Bradley, J.W.; Khamis, R.A.; Sanduk, M.I.; Elliott, J.A.; Rusbridge, M.G.

    1992-01-01

    We have measured the sheath potential around a probe in a range of different plasma conditions in the UMIST, University of Manchester Institute of Science and Technology, quadrupole GOLUX and in a related experiment in which the plasma expands freely to supersonic velocity. In the latter case, the sheath potential agrees well with an appropriately modified form of the usual expression for a field-free plasma, for both hydrogen and argon plasmas. In GOLUX, however, the sheath potential is found to be significantly less than the accepted value, even when the magnetic field is taken into account. For the slow moving plasma in the outer part of the quadrupole confining field, we present both theoretical and experimental results showing that the reduction is due to truncation of the electron velocity distribution as the probe drains electrons from a closed flux tube faster than they can be replaced. In the central hot plasma, however, this explanation cannot apply. Here, the plasma is moving at about sonic speed and magnetic effects are weak. Nevertheless, the results are significantly different from both in the field free experiment. (author)

  18. Reflective measurement of water concentration using millimeter wave illumination

    Science.gov (United States)

    Sung, Shijun; Bennett, David; Taylor, Zachary; Bajwa, Neha; Tewari, Priyamvada; Maccabi, Ashkan; Culjat, Martin; Singh, Rahul; Grundfest, Warren

    2011-04-01

    THz and millimeter wave technology have shown the potential to become a valuable medical imaging tool because of its sensitivity to water and safe, non-ionizing photon energy. Using the high dielectric constant of water in these frequency bands, reflectionmode THz sensing systems can be employed to measure water content in a target with high sensitivity. This phenomenology may lead to the development of clinical systems to measure the hydration state of biological targets. Such measurements may be useful in fast and convenient diagnosis of conditions whose symptoms can be characterized by changes in water concentration such as skin burns, dehydration, or chemical exposure. To explore millimeter wave sensitivity to hydration, a reflectometry system is constructed to make water concentration measurements at 100 GHz, and the minimum detectable water concentration difference is measured. This system employs a 100 GHz Gunn diode source and Golay cell detector to perform point reflectivity measurements of a wetted polypropylene towel as it dries on a mass balance. A noise limited, minimum detectable concentration difference of less than 0.5% by mass can be detected in water concentrations ranging from 70% to 80%. This sensitivity is sufficient to detect hydration changes caused by many diseases and pathologies and may be useful in the future as a diagnostic tool for the assessment of burns and other surface pathologies.

  19. Concentration of Radon Progeny in Air by Alpha Spectrometry Measurement

    International Nuclear Information System (INIS)

    Acena, M. L.; Crespo, M. T.

    1989-01-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of 214 Po and 318 Po. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter. (Author) 15 refs

  20. Low plasma selenium concentrations in critically ill children: the interaction effect between inflammation and selenium deficiency

    Science.gov (United States)

    2014-01-01

    Introduction Low plasma selenium concentrations are frequent in critically ill patients. However, whether this is due to systemic inflammation, a deficient nutritional state or both is still not clear. We aimed to determine the factors associated with low plasma selenium in critically ill children while considering the inflammatory response and nutritional status. Method A prospective study was conducted in 173 children (median age 34 months) with systemic inflammatory response who had plasma selenium concentrations assessed 48 hours after admission and on the 5th day of ICU stay. The normal reference range was 0.58 μmol/L to 1.6 μmol/L. The outcome variable was ‘low plasma selenium’, which was defined as plasma selenium values below the distribution median during this period. The main explanatory variables were age, malnutrition, sepsis, C-reactive protein (CRP), and clinical severity scores. The data were analyzed using a Binomial Generalized Estimating Equations model, which includes the correlation between admission and 5th day responses. Results Malnutrition and CRP were associated with low plasma selenium. The interaction effect between these two variables was significant. When CRP values were less than or equal to 40 mg/L, malnutrition was associated with low plasma selenium levels (odds ratio (OR) = 3.25, 95% confidence interval (CI) 1.39 to 7.63, P = 0.007; OR = 2.98, 95% CI 1.26 to 7.06, P = 0.013; OR = 2.49, 95% CI 1.01 to 6.17, P = 0.049, for CRP = 10, 20 and 40 mg/L, respectively). This effect decreased as CRP concentrations increased and there was loose significance when CRP values were >40 mg/L. Similarly, the effect of CRP on low plasma selenium was significant for well-nourished patients (OR = 1.13; 95% CI 1.06 to 1.22, P selenium. This interaction should be considered when interpreting plasma concentrations as an index of selenium status in patients with systemic inflammation as well as in the decision

  1. The influence of 5-HTTLPR genotype on the association between the plasma concentration and therapeutic effect of paroxetine in patients with major depressive disorder.

    Directory of Open Access Journals (Sweden)

    Tetsu Tomita

    Full Text Available The efficacy of treatment with selective serotonin reuptake inhibitors in patients with major depressive disorder (MDD can differ depending on the patient's serotonin transporter-linked polymorphic region (5-HTTLPR genotype, and the effects of varying plasma concentrations of drugs can also vary. We investigated the association between the paroxetine plasma concentration and clinical response in patients with different 5-HTTLPR genotypes.Fifty-one patients were enrolled in this study. The Montgomery-Asberg Depression Rating Scale (MADRS was used to evaluate patients at 0, 1, 2, 4, and 6 weeks. The patients' paroxetine plasma concentrations at week 6 were measured using high-performance liquid chromatography. Additionally, their 5-HTTLPR polymorphisms (alleles S and L were analyzed using a polymerase chain reaction with specific primers. We divided the participants into two groups based on their L haplotype: the SS group and the SL and LL group. We performed single and multiple regression analyses to investigate the associations between MADRS improvement and paroxetine plasma concentrations or other covariates for each group.There were no significant differences between the two groups with regard to demographic or clinical data. In the SS group, the paroxetine plasma concentration was significantly negatively correlated with improvement in MADRS at week 6. In the SL and LL group, the paroxetine plasma concentration was significantly positively correlated with improvement in MADRS at week 6 according to the results of the single regression analysis; however, it was not significantly correlated with improvement in MADRS at week 6 according to the results of the multiple regression analysis.Among patients with MDD who do not respond to paroxetine, a lower plasma concentration or a lower oral dose of paroxetine might be more effective in those with the SS genotype, and a higher plasma concentration might be more effective in those with the SL or LL

  2. Comparison of predicted and measured variations of indoor radon concentration

    International Nuclear Information System (INIS)

    Arvela, H.; Voutilainen, A.; Maekelaeinen, I.; Castren, O.; Winqvist, K.

    1988-01-01

    Prediction of the variations of indoor radon concentration were calculated using a model relating indoor radon concentration to radon entry rate, air infiltration and meteorological factors. These calculated variations have been compared with seasonal variations of 33 houses during 1-4 years, with winter-summer concentration ratios of 300 houses and the measured diurnal variation. In houses with a slab in ground contact the measured seasonal variations are quite often in agreement with variations predicted for nearly pure pressure difference driven flow. The contribution of a diffusion source is significant in houses with large porous concrete walls against the ground. Air flow due to seasonally variable thermal convection within eskers strongly affects the seasonal variations within houses located thereon. Measured and predicted winter-summer concentration ratios demonstrate that, on average, the ratio is a function of radon concentration. The ratio increases with increasing winter concentration. According to the model the diurnal maximum caused by a pressure difference driven flow occurs in the morning, a finding which is in agreement with the measurements. The model presented can be used for differentiating between factors affecting radon entry into houses. (author)

  3. Associations Between Plasma Chemerin Concentrations and Bone Quality in Adults From the General Population.

    Science.gov (United States)

    Kadric, Lejla; Zylla, Stephanie; Nauck, Matthias; Völzke, Henry; Friedrich, Nele; Hannemann, Anke

    2018-06-01

    Chemerin is an adipokine associated with parameters of inflammation and the metabolic syndrome. Small observational studies suggested that high circulating chemerin levels are also related to bone erosion. We aimed to determine whether plasma chemerin levels are related to bone quality in the general population and to investigate the influence of body mass index (BMI) on that relation. For our analyses, we obtained data from 3583 adults who participated in the population-based Study of Health in Pomerania-Trend. The participants were divided into three groups according to their BMI: lean (<25 kg/m2), overweight (25 to 30 kg/m2), and obese (≥30 kg/m2). Chemerin concentrations were determined in EDTA plasma. Bone quality was assessed using quantitative ultrasound at the heel. Broadband ultrasound attenuation (BUA), speed of sound (SOS), stiffness index, and osteoporotic fracture risk were derived from this measurement. Sex- and BMI-specific linear regression models revealed inverse associations between chemerin levels and BUA in obese men. In obese women, inverse relations between chemerin levels and SOS or stiffness index were found. Logistic regression models revealed positive associations between chemerin levels and osteoporotic fracture risk. In lean or overweight subjects, no statistically significant associations were found. Our sex- and BMI-specific analyses showed that inverse associations between chemerin levels and bone quality are restricted to obese men and women. The observed association may be due to a chemerin-induced negative affect on bone metabolism, possibly due to abrogation of osteoblastogenesis or stimulation of adipogenesis.

  4. MICROWAVE NOISE MEASUREMENT OF ELECTRON TEMPERATURES IN AFTERGLOW PLASMAS

    Energy Technology Data Exchange (ETDEWEB)

    Leiby, Jr., C. C.; McBee, W. D.

    1963-10-15

    Transient electron temperatures in afterglow plasmas were determined for He (5 and 10 torr), Ne, and Ne plus or minus 5% Ar (2.4 and 24 torr) by combining measurements of plasma microwave noise power, and plasma reflectivity and absorptivity. Use of a low-noise parametric preamplifier permitted continuous detection during the afterglow of noise power at 5.5 Bc in a 1 Mc bandwidth. Electron temperature decays were a function of pressure and gas but were slower than predicted by electron energy loss mechanisms. The addition of argon altered the electron density decay in the neon afterglow but the electron temperature decay was not appreciably changed. Resonances in detected noise power vs time in the afterglow were observed for two of the three plasma waveguide geometries studied. These resonances correlate with observed resonances in absorptivity and occur over the same range of electron densities for a given geometry independent of gas type and pressure. (auth)

  5. Development of a laser-induced plasma probe to measure gas phase plasma signals at high pressures and temperatures

    International Nuclear Information System (INIS)

    Gounder, J.D.; Kutne, P.; Meier, W.

    2012-01-01

    The ability of laser induced breakdown spectroscopy (LIBS) technique for on line simultaneous measurement of elemental concentrations has led to its application in a wide number of processes. The simplicity of the technique allows its application to harsh environments such as present in boilers, furnaces and gasifiers. This paper presents the design of a probe using a custom optic which transforms a round beam into a ring (Donut) beam, which is used for forming a plasma in an atmosphere of nitrogen at high pressure (20 bar) and temperature (200 °C). The LIBS experiments were performed using a high pressure cell to characterize and test the effectiveness of the donut beam transmitted through the LIBS probe and collect plasma signal in back scatter mode. The first tests used the second harmonic of a Nd:YAG laser, pulse width 7 ns, to form a plasma in nitrogen gas at five different pressures (1, 5, 10, 15 and 20 bar) and three different gas temperatures (25, 100 and 200 °C). The uniqueness of this probe is the custom made optic used for reshaping the round laser beam into a ring (Donut) shaped laser beam, which is fed into the probe and focused to form a plasma at the measurement point. The plasma signal is collected and collimated using the laser focusing lens and is reflected from the laser beam axis onto an achromatic lens by a high reflection mirror mounted in the center section of the donut laser beam. The effect of gas pressure and temperature on N(I) lines in the high pressure cell experiment shows that the line intensity decreases with pressure and increases with temperature. Mean plasma temperature was calculated using the ratios of N(I) line intensities ranging from 7400 K to 8900 K at 1 bar and 2400 K to 3200 K at 20 bar for the three different gas temperatures. The results show that as a proof of principle the donut beam optics in combination with the LIBS probe can be used for performing extensive LIBS measurements in well controlled laboratory

  6. Development of a laser-induced plasma probe to measure gas phase plasma signals at high pressures and temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Gounder, J.D., E-mail: James.Gounder@dlr.de; Kutne, P.; Meier, W.

    2012-08-15

    The ability of laser induced breakdown spectroscopy (LIBS) technique for on line simultaneous measurement of elemental concentrations has led to its application in a wide number of processes. The simplicity of the technique allows its application to harsh environments such as present in boilers, furnaces and gasifiers. This paper presents the design of a probe using a custom optic which transforms a round beam into a ring (Donut) beam, which is used for forming a plasma in an atmosphere of nitrogen at high pressure (20 bar) and temperature (200 Degree-Sign C). The LIBS experiments were performed using a high pressure cell to characterize and test the effectiveness of the donut beam transmitted through the LIBS probe and collect plasma signal in back scatter mode. The first tests used the second harmonic of a Nd:YAG laser, pulse width 7 ns, to form a plasma in nitrogen gas at five different pressures (1, 5, 10, 15 and 20 bar) and three different gas temperatures (25, 100 and 200 Degree-Sign C). The uniqueness of this probe is the custom made optic used for reshaping the round laser beam into a ring (Donut) shaped laser beam, which is fed into the probe and focused to form a plasma at the measurement point. The plasma signal is collected and collimated using the laser focusing lens and is reflected from the laser beam axis onto an achromatic lens by a high reflection mirror mounted in the center section of the donut laser beam. The effect of gas pressure and temperature on N(I) lines in the high pressure cell experiment shows that the line intensity decreases with pressure and increases with temperature. Mean plasma temperature was calculated using the ratios of N(I) line intensities ranging from 7400 K to 8900 K at 1 bar and 2400 K to 3200 K at 20 bar for the three different gas temperatures. The results show that as a proof of principle the donut beam optics in combination with the LIBS probe can be used for performing extensive LIBS measurements in well controlled

  7. Increased concentrations of plasma IL-18 in patients with hepatic dysfunction after hepatectomy.

    Science.gov (United States)

    Shibata, M; Hirota, M; Nozawa, F; Okabe, A; Kurimoto, M; Ogawa, M

    2000-10-01

    We investigated the dynamic aspects of circulatory IL-18 and other inflammatory cytokines in patients who underwent a hepatectomy. In patients with post-operative hepatic dysfunction, plasma concentrations of these cytokines increased, reflecting severe surgical trauma. IL-6, IL-10 and IFN-gamma increased in the early phase, while IL-18 increased in the later phase after 1 week. Interestingly, the increase in the plasma IL-18 concentration was correlated with that in serum bilirubin levels in hepatectomized patients. Hence, the decrease in the hepatic metabolism of IL-18 may cause the plasma accumulation of IL-18. This mechanism was confirmed using rat experiments. Intravenously administered human IL-18 was excreted into bile. Furthermore, the plasma clearance of human IL-18 was prolonged in bile duct-ligated rats. These results suggest that IL-18 is metabolized in the liver and excreted into bile, and an increase in plasma IL-18 in patients with hepatic dysfunction reflects the decreased metabolism in the liver. Copyright 2000 Academic Press.

  8. Acute phase response and plasma carotenoid concentrations in older women: findings from the nun study.

    Science.gov (United States)

    Boosalis, M G; Snowdon, D A; Tully, C L; Gross, M D

    1996-01-01

    This cross-sectional study investigated whether the acute phase response was associated with suppressed circulating levels of antioxidants in a population of 85 Catholic sisters (nuns) ages 77-99 y. Fasting blood was drawn to determine the presence of an acute phase response, as defined by an elevation in the serum concentration of C-reactive protein. Serum concentrations of albumin, thyroxine-binding prealbumin, zinc, copper, and fibrinogen were determined as were plasma concentrations of carotenoids and alpha tocopherol. Results showed that the presence of an acute phase response was associated with (1) an expected significant decrease in the serum concentrations of albumin (p < 0.001) and thyroxine-binding prealbumin (p < 0.001); (2) an expected significant increase in copper (p < 0.001) and fibrinogen (p = 0.003); and (3) a significant decrease in the plasma concentrations of lycopene (p = 0.03), alpha carotene (p = 0.02), beta carotene (p = 0.02), and total carotenoids (p = 0.01). The acute phase response was associated with decreased plasma levels of the antioxidants lycopene, alpha carotene, and beta carotene. This decrease in circulating antioxidants may further compromise antioxidant status and increase oxidative stress and damage in elders.

  9. HEMOFILTRATION AND COUPLED PLASMA FILTRATION ADSORPTION IMPACT ON TACROLIMUS BLOOD CONCENTRATION IN RENAL TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    A.V. Vatazin

    2014-01-01

    Full Text Available Aim. To study the effect of hemofi ltration and coupled plasma fi ltration adsorption on tacrolimus blood concentration in renal transplant recipients.Methods and results. The study included 8 renal transplant recipients. In these patients immediately after the operation was performed the coupled plasma fi ltration adsorption with hemofiltration using a cartridge Mediasorb to reduce the severity of reperfusion injury. We have found that during this extracorporeal blood correction procedure there was statistically not signifi cant decrease of tacrolimus blood concentration. However, concentration of tacrolimus remained in the therapeutic range even after the procedure and it was not signifi cantly different from the control point С0.Conclusion. Coupled plasma fi ltration adsorption is safe in renal transplant recipients and has no signifi cant impact on tacrolimus blood concentration. However, the downward trend in the concentration of tacrolimus in the course of these procedures, especially in continuous or semicontinuous mode, as well as in patients with low hematocrit and hypoalbuminemia, requires individual monitoring.

  10. The Relationship between the Plasma Triglyceride Concentration and the Severity of Acute Respiratory Distress Syndrome

    Directory of Open Access Journals (Sweden)

    V. V. Kuzkov

    2012-01-01

    Full Text Available Triglycerides (TG may be involved in the pathogenesis of critical impairments. Objective: to study the relationship between the plasma concentration of TG, the outcome of the disease, and the markers of its severity in intensive care unit patients with early-stage acute respiratory distress syndrome (ARDS. Subjects and methods. The prospective study included 18 patients with acute lung injury (ALI, who needed respiratory support. For further analysis, all the patients were divided into groups with TG < 1.00 mmol/l (TGlow; n=7 and >1.00 mmol/l (TGhigh; n=11. Results. A negative correlation was found between plasma TG concentration and oxygenation index (PaO2/FiO2. In the TG^jgh group, extravas-cular lung water index was significantly higher and cardiac index was lower than those in the TGlow group. Among the deceased patients, there was a 1.03 mmol/l reduction in TG concentration by day 4 of the study whereas in the survivors, TG concentration increased by an average of 0.15 mmol/l (p=0.02. Conclusion. In the patients with ALI, the plasma concentration of TG is related to oxygenation impairments and the degree of pulmonary edema, as well as with the outcome of the disease. Key words: triglycerides, acute lung injury, extravascular lung water index, pulmonary edema.

  11. Kinetic and Related Determinants of Plasma Triglyceride Concentration in Abdominal Obesity: Multicenter Tracer Kinetic Study.

    Science.gov (United States)

    Borén, Jan; Watts, Gerald F; Adiels, Martin; Söderlund, Sanni; Chan, Dick C; Hakkarainen, Antti; Lundbom, Nina; Matikainen, Niina; Kahri, Juhani; Vergès, Bruno; Barrett, P Hugh R; Taskinen, Marja-Riitta

    2015-10-01

    Patients with obesity and diabetes mellitus have increased risk of cardiovascular disease. A major cause is an atherogenic dyslipidemia related primarily to elevated plasma concentrations of triglyceride-rich lipoproteins. The aim of this study was to clarify determinants of plasma triglyceride concentration. We focused on factors that predict the kinetics of very-low density lipoprotein 1 (VLDL1) triglycerides. A multicenter study using dual stable isotopes (deuterated leucine and glycerol) and multicompartmental modeling was performed to elucidate the kinetics of triglycerides and apoB in VLDL1 in 46 subjects with abdominal obesity and additional cardiometabolic risk factors. Results showed that plasma triglyceride concentrations were dependent on both the secretion rate (r=0.44, Ptriglycerides and VLDL1-apoB. Liver fat mass was independently and directly associated with secretion rates of VLDL1-triglycerides (r=0.56, Ptriglycerides (r=0.48, Ptriglyceride concentrations in abdominal obesity are determined by the kinetics of VLDL1 subspecies, catabolism being mainly dependent on apoC-III concentration and secretion on liver fat content. Reduction in liver fat and targeting apoC-III may be an effective approach for correcting triglyceride metabolism atherogenic dyslipidemia in obesity. © 2015 American Heart Association, Inc.

  12. Measurement of Uranium in Blood-Plasma of Bavarian Females

    International Nuclear Information System (INIS)

    Chaudhri, M.A.; Watling, R.J.

    2011-01-01

    It has recently been reported that the water supply in some parts of Bavaria (Germany) contains Uranium. In order to study its effects we have determined the concentrations of U in the blood plasma of 25 females. All the females came from Bavaria and were not on any medication. Blood samples were drawn from a superficial arm vein, centrifuged and plasma extracted. The plasma samples were freeze-dried and analysed in our Analytical Laboratory in Perth, Western Australia by using the technique of ICP-MS. The U contents found varied from less than 0.1 to 8.2 ppb (6.6 ng/L to 543 ng/L)

  13. Childhood obesity treatment; Effects on BMI SDS, body composition, and fasting plasma lipid concentrations

    DEFF Research Database (Denmark)

    Nielsen, Tenna Ruest Haarmark; Fonvig, Cilius Esmann; Dahl, Maria

    2018-01-01

    Objective The body mass index (BMI) standard deviation score (SDS) may not adequately reflect changes in fat mass during childhood obesity treatment. This study aimed to investigate associations between BMI SDS, body composition, and fasting plasma lipid concentrations at baseline and during......, and 80% improved their lipid concentrations. Conclusion Reductions in the degree of obesity during multidisciplinary childhood obesity treatment are accompanied by improvements in body composition and fasting plasma lipid concentrations. Even in individuals increasing their BMI SDS, body composition...... childhood obesity treatment. Methods 876 children and adolescents (498 girls) with overweight/obesity, median age 11.2 years (range 1.6±21.7), and median BMI SDS 2.8 (range 1.3±5.7) were enrolled in a multidisciplinary outpatient treatment program and followed for a median of 1.8 years (range 0...

  14. Duloxetine Plasma Concentrations and Its Effectiveness in the Treatment of Nonorganic Chronic Pain in the Orofacial Region.

    Science.gov (United States)

    Kobayashi, Yuka; Nagashima, Wataru; Tokura, Tatsuya; Yoshida, Keizo; Umemura, Eri; Miyauchi, Tomoya; Arao, Munetaka; Ito, Mikiko; Kimura, Hiroyuki; Kurita, Kenichi; Ozaki, Norio

    The purpose of this study was to examine the relationship between the pain-relieving effects of duloxetine and its plasma concentrations in patients with burning mouth syndrome and atypical odontalgia characterized by chronic nonorganic pain in the orofacial region. We administered duloxetine to 77 patients diagnosed as having burning mouth syndrome or atypical odontalgia for 12 weeks. The initial dose of duloxetine was established as 20 mg/d and was increased to 40 mg/d after week 2. We evaluated pain using the visual analog scale and depressive symptoms using the Structured Interview Guide for the Hamilton Depression Rating Scale at weeks 0, 2, 4, 6, 8, 10, and 12 and measured plasma concentrations of duloxetine 12 weeks after the start of its administration. Visual analog scale scores were significantly lower 12 weeks after than at the start of the administration of duloxetine (paired t test, t = 6.65, P pain in patients with chronic nonorganic pain in the orofacial region. However, no relationship was observed between its pain-relieving effects and plasma concentrations.

  15. Measurement of apolipoprotein B radioactivity in whole blood plasma by precipitation with isopropanol

    International Nuclear Information System (INIS)

    Yamada, N.; Havel, R.J.

    1986-01-01

    A method to measure apolipoprotein B radioactivity in whole blood plasma is described that is suitable for routine use in kinetic experiments in vivo. Radiolabeled apolipoprotein B is precipitated from plasma diluted 15- to 30-fold in the presence of carrier low density lipoproteins by 50% isopropanol. The amount of radioiodine in apoB is estimated from the difference between total radioiodine concentration in whole plasma and the fraction soluble in 50% isopropanol. Addition of up to 100 microliters of plasma to radioiodinated lipoproteins did not alter the percent of radioiodine precipitated in 1500 microliters of 50% isopropanol. The percent of radioiodine precipitated by isopropanol 3 min after intravenous injection of homologous radioiodinated very low density lipoproteins, intermediate density lipoproteins, and low density lipoproteins into rabbits was almost identical to that in the injected lipoproteins (y = 1.009 X +/- 0.462; r = 0.997)

  16. Measurements of plasma density fluctuations and electric wave fields using spherical electrostatic probes

    International Nuclear Information System (INIS)

    Eriksson, A.I.; Bostroem, R.

    1995-04-01

    Spherical electrostatic probes are in wide use for the measurements of electric fields and plasma density. This report concentrates on the measurements of fluctuations of these quantities rather than background values. Potential problems with the technique include the influence of density fluctuations on electric field measurements and vice versa, effects of varying satellite potential, and non-linear rectification in the probe and satellite sheaths. To study the actual importance of these and other possible effects, we simulate the response of the probe-satellite system to various wave phenomena in the plasma by applying approximate analytical as well as numerical methods. We use a set of non-linear probe equations, based on probe characteristics experimentally obtained in space, and therefore essentially independent of any specific probe theory. This approach is very useful since the probe theory for magnetized plasmas is incomplete. 47 refs

  17. Comparing predicted estrogen concentrations with measurements in US waters

    International Nuclear Information System (INIS)

    Kostich, Mitch; Flick, Robert; Martinson, John

    2013-01-01

    The range of exposure rates to the steroidal estrogens estrone (E1), beta-estradiol (E2), estriol (E3), and ethinyl estradiol (EE2) in the aquatic environment was investigated by modeling estrogen introduction via municipal wastewater from sewage plants across the US. Model predictions were compared to published measured concentrations. Predictions were congruent with most of the measurements, but a few measurements of E2 and EE2 exceed those that would be expected from the model, despite very conservative model assumptions of no degradation or in-stream dilution. Although some extreme measurements for EE2 may reflect analytical artifacts, remaining data suggest concentrations of E2 and EE2 may reach twice the 99th percentile predicted from the model. The model and bulk of the measurement data both suggest that cumulative exposure rates to humans are consistently low relative to effect levels, but also suggest that fish exposures to E1, E2, and EE2 sometimes substantially exceed chronic no-effect levels. -- Highlights: •Conservatively modeled steroidal estrogen concentrations in ambient water. •Found reasonable agreement between model and published measurements. •Model and measurements agree that risks to humans are remote. •Model and measurements agree significant questions remain about risk to fish. •Need better understanding of temporal variations and their impact on fish. -- Our model and published measurements for estrogens suggest aquatic exposure rates for humans are below potential effect levels, but fish exposure sometimes exceeds published no-effect levels

  18. The active titration method for measuring local hydroxyl radical concentration

    Science.gov (United States)

    Sprengnether, Michele; Prinn, Ronald G.

    1994-01-01

    We are developing a method for measuring ambient OH by monitoring its rate of reaction with a chemical species. Our technique involves the local, instantaneous release of a mixture of saturated cyclic hydrocarbons (titrants) and perfluorocarbons (dispersants). These species must not normally be present in ambient air above the part per trillion concentration. We then track the mixture downwind using a real-time portable ECD tracer instrument. We collect air samples in canisters every few minutes for roughly one hour. We then return to the laboratory and analyze our air samples to determine the ratios of the titrant to dispersant concentrations. The trends in these ratios give us the ambient OH concentration from the relation: dlnR/dt = -k(OH). A successful measurement of OH requires that the trends in these ratios be measureable. We must not perturb ambient OH concentrations. The titrant to dispersant ratio must be spatially invariant. Finally, heterogeneous reactions of our titrant and dispersant species must be negligible relative to the titrant reaction with OH. We have conducted laboratory studies of our ability to measure the titrant to dispersant ratios as a function of concentration down to the few part per trillion concentration. We have subsequently used these results in a gaussian puff model to estimate our expected uncertainty in a field measurement of OH. Our results indicate that under a range of atmospheric conditions we expect to be able to measure OH with a sensitivity of 3x10(exp 5) cm(exp -3). In our most optimistic scenarios, we obtain a sensitivity of 1x10(exp 5) cm(exp -3). These sensitivity values reflect our anticipated ability to measure the ratio trends. However, because we are also using a rate constant to obtain our (OH) from this ratio trend, our accuracy cannot be better than that of the rate constant, which we expect to be about 20 percent.

  19. Development of negative heavy ion sources for plasma potential measurement

    International Nuclear Information System (INIS)

    Sasao, M.; Okabe, Y.; Fujisawa, A.; Iguchi, H.; Fujita, J.; Yamaoka, H.; Wada, M.

    1991-10-01

    A plasma sputter negative ion source was studied for its applicability to the potential measurement of a fusion plasma. Both the beam current density and the beam energy spread are key issues. Energy spectra of a self extracted Au - beam from the source were measured under the condition of a constant work function of the production surface. The full width of half maximum (FWHM) increases from 3 eV to 9 eV monotonically as the target voltage increases from 50 V to 300 V, independently from the target surface work function of 2.2 - 3 eV. (author)

  20. Electron temperature measurements in lowdensity plasmas by helium spectroscopy

    International Nuclear Information System (INIS)

    Brenning, N.

    1977-09-01

    This method to use relative intensities of singlet and triplet lines of neutral helium to measure electron temperature in low-density plasmas is examined. Calculations from measured and theoretical data about transitions in neutral helium are carried out and compared to experimental results. It is found that relative intensities of singlet and triplet lines from neutral helium only can be used for TE determination in low-density, short-duration plasmas. The most important limiting processes are excitation from the metastable 2 3 S level and excitation transfer in collisions between electrons and excited helium atoms. An evaluation method is suggested, which minimizes the effect of these processes. (author)

  1. Electron density measurement for steady state plasmas

    International Nuclear Information System (INIS)

    Kawano, Yasunori; Chiba, Shinichi; Inoue, Akira

    2000-01-01

    Electron density of a large tokamak has been measured successfully by the tangential CO 2 laser polarimeter developed in JT-60U. The tangential Faraday rotation angles of two different wavelength of 9.27 and 10.6 μm provided the electron density independently. Two-color polarimeter concept for elimination of Faraday rotation at vacuum windows is verified for the first time. A system stability for long time operation up to ∼10 hours is confirmed. A fluctuation of a signal baseline is observed with a period of ∼3 hours and an amplitude of 0.4 - 0.7deg. In order to improve the polarimeter, an application of diamond window for reduction of the Faraday rotation at vacuum windows and another two-color polarimeter concept for elimination of mechanical rotation component are proposed. (author)

  2. Plasma fluctuation measurements in tokamaks using beam-plasma interactions (abstract)

    International Nuclear Information System (INIS)

    Fonck, R.J.; Duperrex, P.A.; Paul, S.F.

    1990-01-01

    High-frequency observations of light emitted from the interactions between plasma ions and injected neutral beam atoms allow the measurement of moderate-wavelength fluctuations in plasma and impurity ion densities. To detect turbulence in the local plasma ion density, the collisionally excited fluorescence from a neutral beam is measured either separately at several spatial points or with a multichannel imaging detector. Similarly, the role of impurity ion density fluctuations is measured using charge exchange recombination excited transitions emitted by the ion species of interest. This technique can access the relatively unexplored region of long-wavelength plasma turbulence with k perpendicular ρ i much-lt 1, and hence complements measurements from scattering experiments. Optimization of neutral beam geometry and optical sightlines can result in very good localization and resolution (Δx≤1 cm) in the hot plasma core region. The detectable fluctuation level is determined by photon statistics, atomic excitation processes, and beam stability, but can be as low as 0.2% in a 100 kHz bandwidth over the 0--1 MHz frequency range. The choices of beam species (e.g., H 0 , He 0 , etc.), observed transition (e.g., H α , L α , He I singlet or triplet transitions, C VI Δn=1, etc.) are dictated by experiment-specific factors such as optical access, flexibility of beam operation, plasma conditions, and detailed experimental goals. Initial tests on the PBX-M tokamak using the H α emissions from a heating neutral beam show low-frequency turbulence in the edge plasma region

  3. Influence of preoperative oral rehydration on arterial plasma rocuronium concentrations and neuromuscular blocking effects: A randomised controlled trial.

    Science.gov (United States)

    Ishigaki, Sayaka; Ogura, Takahiro; Kanaya, Ayana; Miyake, Yu; Masui, Kenichi; Kazama, Tomiei

    2017-01-01

    The influence of preoperative rehydration on the action of rocuronium has not yet been investigated. The objective is to evaluate the hypothesis that preoperative rehydration lowers arterial rocuronium plasma concentrations and changes its associated neuromuscular blocking effects during induction of anaesthesia. Randomised, single-blinded study. A secondary hospital from October 2013 to July 2014. In total, 46 men undergoing elective surgery were eligible to participate and were randomly allocated into two groups. Exclusion criteria were severe hepatic, renal or cardiovascular disorder; neuromuscular disease; history of allergy to rocuronium; BMI more than 30 kg m; receiving medication known to influence neuromuscular function. Participants received 1500 ml of oral rehydration solution (rehydration group) or none (control group) until 2 hours before anaesthesia. Arterial blood samples were obtained 60, 90 and 120 s and 30 min after rocuronium (0.6 mg kg) administration during total intravenous anaesthesia. Responses to 0.1-Hz twitch stimuli were measured at the adductor pollicis muscle using acceleromyography. Arterial plasma rocuronium concentrations. Arterial plasma rocuronium concentrations at 60, 90 and 120 s in the rehydration and control groups were 9.9 and 13.7, 6.8 and 9.5 and 6.2 and 8.1 μg ml, respectively (P = 0.02, 0.003 and 0.02, respectively); the onset times in the rehydration and control groups were 92.0 and 69.5 s (P = 0.01), and the times to twitch re-appearance were 25.3 and 30.4 min (P = 0.004), respectively. Preoperative rehydration significantly reduces arterial plasma rocuronium concentrations in the first 2 minutes after administration, prolonging the onset time and shortening the duration of effect. A higher dose or earlier administration should be considered for patients who receive preoperative rehydration. Umin identifier: UMIN000011981.

  4. Continuous measurement of uranium concentrations with the laser spark

    International Nuclear Information System (INIS)

    Gutmacher, R.G.; Cremers, D.A.; Wachter, J.R.

    1987-01-01

    Laser-induced breakdown spectroscopy has been applied to the continuous determination of uranium concentrations between 0.1 and 300 g/L in flowing solutions. The technique is rapid, noninvasive, and unaffected by radioactivity. A concentration of 10 g/L was measured with 0.8% precision in 3 min. Substances that absorb at the laser wavelength, suspended materials, and variations in the acidity of the solution have little or no effect on the results. High concentrations of zirconium, cadmium, aluminum, or stainless steel in solution do not interfere

  5. Fluorescence measurement of atomic oxygen concentration in a dielectric barrier discharge

    Science.gov (United States)

    Dvořák, P.; Mrkvičková, M.; Obrusník, A.; Kratzer, J.; Dědina, J.; Procházka, V.

    2017-06-01

    Concentration of atomic oxygen was measured in a volume dielectric barrier discharge (DBD) ignited in mixtures of Ar + O2(+ H2) at atmospheric pressure. Two-photon absorption laser induced fluorescence (TALIF) of atomic oxygen was used and this method was calibrated by TALIF of Xe in a mixture of argon and a trace of xenon. The calibration was performed at atmospheric pressure and it was shown that quenching by three-body collisions has negligible effect on the life time of excited Xe atoms. The concentration of atomic oxygen in the DBD was around 1021 m-3 and it was stable during the whole discharge period. The concentration did not depend much on the electric power delivered to the discharge provided that the power was sufficiently high so that the visible discharge filled the whole reactor volume. Both the addition of hydrogen or replacing of argon by helium led to a significant decrease of atomic oxygen concentration. The TALIF measurements of O concentration levels in the DBD plasma performed in this work are made use of e.g. in the field analytical chemistry. The results contribute to understanding the processes of analyte hydride preconcentration and subsequent atomization in the field of trace element analysis where DBD plasma atomizers are employed.

  6. Measurement of plasma edge profile on Wendelstein 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Drews, Philipp; Liang, Yunfeng; Neubauer, Olaf; Denner, Peter; Rack, Michael; Liu, Shaocheng; Wang, Nunchao; Nicolai, Dirk; Hollfeld, Klaus; Satheeswaran, Guruparan [Forschungszentrum Juelich, IEK4, Juelich (Germany); Grulke, Olaf [Max-Planck-Institut fuer Plasmaphysik, Greifswald (Germany); Collaboration: W7-X Team

    2016-07-01

    Wendelstein 7-X (W7-X), currently under commissioning at the IPP Greifswald, will be the world's largest stellarator with modular superconducting coils, which will enable steady-state-like plasma operation of up to thirty minutes in order to explore the reactor relevance of this concept. The first operation phase of W7-X will employ a limiter configuration. It will be used primarily for setting up the diagnostics and testing the magnetic configuration. In conjunction with the multipurpose manipulator, a fast reciprocating probe is installed. The combined probe head will be used to measure the radial distribution of the magnetic field using magnetic pick-up coils; the plasma temperature and density profiles and the radial electric field using Langmuir pins; and the plasma flows using a Mach setup. As a quasi-isodynamic stellarator, it has been predicted that not only neoclassical but also turbulent transport will be comparable to or possibly even lower than that of tokamaks. Edge plasma profile measurements, especially those of the electron temperature and density, will play a key role in validating this performance in comparison to the tokamak and hence the viability of a stellarator fusion reactor. The edge plasma profile measurements using the combined probe head are presented.

  7. Measurements in Concentrated Sun using a Remote Controlled Robot

    Directory of Open Access Journals (Sweden)

    Dan Floroian

    2013-04-01

    Full Text Available Nowdays, using the concentrated sunlight is a big issue because the amount of energy is very high and the light is concentrated in a very small area. The main problem in this situation is the heating, and in order to make safe measurements a remote controlled robot is needed. After that, a remote controlled robot will assume the duty of protect the measured sample and to expose it for a precise time to the concentrated sun in order to reduce heating of the sample. For easy operating, and for automatize the process, all the duties, starting with initial conditions, continuing with triggering the measurements, and conditioning the signals and finalizing with data saving must be assured by the robot.

  8. Measurement of average radon gas concentration at workplaces

    International Nuclear Information System (INIS)

    Kavasi, N.; Somlai, J.; Kovacs, T.; Gorjanacz, Z.; Nemeth, Cs.; Szabo, T.; Varhegyi, A.; Hakl, J.

    2003-01-01

    In this paper results of measurement of average radon gas concentration at workplaces (the schools and kindergartens and the ventilated workplaces) are presented. t can be stated that the one month long measurements means very high variation (as it is obvious in the cases of the hospital cave and the uranium tailing pond). Consequently, in workplaces where the expectable changes of radon concentration considerable with the seasons should be measure for 12 months long. If it is not possible, the chosen six months period should contain summer and winter months as well. The average radon concentration during working hours can be differ considerable from the average of the whole time in the cases of frequent opening the doors and windows or using artificial ventilation. (authors)

  9. Plasma dispositions and concentrations of ivermectin in eggs following treatment of laying hens.

    Science.gov (United States)

    Cirak, V Y; Aksit, D; Cihan, H; Gokbulut, C

    2018-05-01

    To determine the plasma disposition and concentrations of ivermectin (IVM) in eggs produced by laying hens following S/C, oral and I/V administration. Twenty-four laying hens, aged 37 weeks and weighing 1.73 (SD 0.12) kg were allocated to three groups of eight birds. The injectable formulation of IVM was administered either orally, S/C, or I/V, at a dose of 0.2 mg/kg liveweight, following dilution (1:5, v/v) with propylene glycol. Heparinised blood samples were collected at various times between 0.25 hours and 20 days after drug administration. Eggs produced by hens were also collected daily throughout the study period. Samples of plasma and homogenised egg were analysed using HPLC. Maximum concentrations of IVM in plasma and mean residence time of IVM were lower after oral (10.2 (SD 7.2) ng/mL and 0.38 (SD 0.14) days, respectively) than after S/C (82.9 (SD 12.4) ng/mL and 1.05 (SD 0.24) days, respectively) administration (pV administration, and until 15 days after S/C administration. Peak concentrations of IVM were 15.7, 23.3 and 1.9 µg/kg, observed 2, 5 and 4 days after I/V, S/C and oral administration, respectively. The low plasma bioavailability of IVM observed after oral administration in laying hens could result in lower efficacy or subtherapeutic plasma concentrations, which may promote the development of parasitic drug resistance. Due to high IVM residues in eggs compared to the maximum residue limits for other food-producing animal species, a withdrawal period should be necessary for eggs after IVM treatment in laying hens.

  10. The influence of environmental variables on platelet concentration in horse platelet-rich plasma.

    Science.gov (United States)

    Rinnovati, Riccardo; Romagnoli, Noemi; Gentilini, Fabio; Lambertini, Carlotta; Spadari, Alessandro

    2016-07-04

    Platelet-rich plasma (PRP) commonly refers to blood products which contain a higher platelet (PLT) concentration as compared to normal plasma. Autologous PRP has been shown to be safe and effective in promoting the natural processes of soft tissue healing or reconstruction in humans and horses. Variability in PLT concentration has been observed in practice between PRP preparations from different patients or from the same individual under different conditions. A change in PLT concentration could modify PRP efficacy in routine applications. The aim of this study was to test the influence of environmental, individual and agonistic variables on the PLT concentration of PRP in horses. Six healthy Standardbred mares were exposed to six different variables with a one-week washout period between variables, and PRP was subsequently obtained from each horse. The variables were time of withdrawal during the day (morning/evening), hydration status (overhydration/dehydration) treatment with anti-inflammatory drugs and training periods on a treadmill. The platelet concentration was significantly higher in horses treated with a non-steroidal anti-inflammatory drug (P = 0.03). The leukocyte concentration increased 2-9 fold with respect to whole blood in the PRP which was obtained after exposure to all the variable considered. Environmental variation in platelet concentration should be taken into consideration during PRP preparation.

  11. Plasma homocyst(e)ine concentrations in pregnant and nonpregnant women with controlled folate intake.

    Science.gov (United States)

    Bonnette, R E; Caudill, M A; Boddie, A M; Hutson, A D; Kauwell, G P; Bailey, L B

    1998-08-01

    To assess the effects of folate intake and pregnancy on plasma total homocyst(e)ine concentrations in women during the second trimester of pregnancy compared with young, healthy nonpregnant women. The diet provided either 450 or 850 microg of folate per day. These levels are approximately the current (400 microg/day) and previous (800 microg/day) Recommended Dietary Allowances for folate in pregnant women. Folate was provided as both food folate (120 microg/day) and supplemental folic acid (either 330 or 730 microg/day) for a period of 12 weeks. Plasma homocyst(e)ine (sum of free and protein-bound homocysteine), serum folate, and erythrocyte folate concentrations were determined weekly. Homocyst(e)ine concentrations were lower in pregnant women during the second trimester of normal pregnancy than in nonpregnant controls, independent of dietary folate intake. The overall mean (+/- standard deviation) homocyst(e)ine concentration of the pregnant subjects (5.4 +/- 1.4 micromol/L) was significantly lower than that observed in the nonpregnant control group (8.7 +/- 1.7 micromol/L) (P ine concentrations remained constant throughout the 12 weeks of the investigation. The folate intakes in this investigation were adequate to maintain constant homocyst(e)ine concentrations in pregnant and nonpregnant women. The lower homocyst(e)ine concentrations observed in pregnant subjects compared with nonpregnant controls may be a physiologic response to pregnancy.

  12. Effect of vitamin E intake from food and supplement sources on plasma α- and γ-tocopherol concentrations in a healthy Irish adult population.

    Science.gov (United States)

    Zhao, Yang; Monahan, Frank J; McNulty, Breige A; Gibney, Mike J; Gibney, Eileen R

    2014-11-14

    Vitamin E is believed to play a preventive role in diseases associated with oxidative stress. The aims of the present study were to quantify vitamin E intake levels and plasma concentrations and to assess dietary vitamin E adequacy in Irish adults. Intake data from the National Adult Nutrition Survey were used; plasma samples were obtained from a representative cohort of survey participants. Plasma α- and γ-tocopherol concentrations were measured by HPLC. The main sources of vitamin E in the diet were 'butter, spreadable fats and oils' and 'vegetables and vegetable dishes'. When vitamin E intake from supplements was taken into account, supplements were found to be the main contributor, making a contribution of 29·2 % to vitamin E intake in the total population. Supplement consumers had significantly higher plasma α-tocopherol concentrations and lower plasma γ-tocopherol concentrations when compared with non-consumers. Consumers of 'vitamin E' supplements had significantly higher vitamin E intake levels and plasma α-tocopherol concentrations compared with consumers of other types of supplements, such as multivitamin and fish oil. Comparison with the Institute of Medicine Estimated Average Requirement of 12 mg/d indicated that when vitamin E intake from food and supplement sources was taken into account, 100 % of the study participants achieved the recommended intake levels. When vitamin E intake from food sources was taken into account, only 68·4 % of the females were found to achieve the recommended intake levels compared with 99·2 % of the males. The results of the present study show that dietary vitamin E intake has a significant effect on plasma α- and γ-tocopherol concentrations. Furthermore, they show that the consumption of supplements is a major contributor to overall intake and has a significant effect on plasma vitamin E concentrations in the Irish population.

  13. TXRF 'measurements' of concentration distribution below the detection limit

    International Nuclear Information System (INIS)

    Kubala-Kukus, A.; Banas, D.; Braziewicz, J.; Majewska, U.; Mrowczynski, S.; Pajek, M.

    2000-01-01

    We demonstrate that a shape of the concentration distribution of the element in a set of samples, as measured by the TXRF method, can be determined even for the concentrations below the detection limit (DL). This can be done, when the measurements reporting the concentration below DL level are included properly in the analysis of the results. The method developed for such correction is presented and discussed. It is demonstrated that this correction is particularly important when the studied concentrations are close to the DL level of the method, which is a common case for TXRF. In the paper a precision of the developed correction is discussed in details, by using the results of numerical simulations of experiments for different concentration distributions and number of performed measurements. It is demonstrated that the factor, which limits the accuracy of the correction, is the number of measurements, not the correction procedure itself. The applicability and importance of the developed correction is demonstrated for routine TXRF analysis of different types of samples of bio-medical interest. (author)

  14. Effect of sampling site, repeated sampling, pH, and PCO2 on plasma lactate concentration in healthy dogs.

    Science.gov (United States)

    Hughes, D; Rozanski, E R; Shofer, F S; Laster, L L; Drobatz, K J

    1999-04-01

    To characterize the variation in plasma lactate concentration among samples from commonly used blood sampling sites in conscious, healthy dogs. 60 healthy dogs. Cross-sectional study using a replicated Latin square design. Each dog was assigned to 1 of 6 groups (n = 10) representing all possible orders for 3 sites (cephalic vein, jugular vein, and femoral artery) used to obtain blood. Samples were analyzed immediately, by use of direct amperometry for pH, PO2, Pco2, glucose, and lactate concentration. Significant differences in plasma lactate concentrations were detected among blood samples from the cephalic vein (highest), femoral artery, and jugular vein (lowest). Mean plasma lactate concentration in the first sample obtained, irrespective of sampling site, was lower than in subsequent samples. Covariation was identified among plasma lactate concentration, pH, and PCO2, but correlation coefficients were low. Plasma lactate concentrations differed among blood samples from various sites. A reference range for plasma lactate concentration was 0.3 to 2.5 mmol/L. Differences in plasma lactate concentrations among samples from various sites and with repeated sampling, in healthy dogs, are small. Use of the reference range may facilitate the clinical use of plasma lactate concentration in dogs.

  15. QA/QC For Radon Concentration Measurement With Charcoal Canister

    International Nuclear Information System (INIS)

    Pantelic, G.; Zivanovic, M.; Rajacic, M.; Krneta Nikolic, J.; Todorovic, D.

    2015-01-01

    The primary concern of any measuring of radon or radon progeny must be the quality of the results. A good quality assurance program, when properly designed and diligently followed, ensures that laboratory staff will be able to produce the type and quality of measurement results which is needed and expected. Active charcoal detectors are used for testing the concentration of radon in dwellings. The method of measurement is based on radon adsorption on coal and measurement of gamma radiation of radon daughters. Upon closing the detectors, the measurement was carried out after achieving the equilibrium between radon and its daughters (at least 3 hours) using NaI or HPGe detector. Radon concentrations as well as measurement uncertainties were calculated according to US EPA protocol 520/5-87-005. Detectors used for the measurements were calibrated by 226Ra standard of known activity in the same geometry. Standard and background canisters are used for QA and QC, as well as for the calibration of the measurement equipment. Standard canister is a sealed canister with the same matrix and geometry as the canisters used for measurements, but with the known activity of radon. Background canister is a regular radon measurement canister, which has never been exposed. The detector background and detector efficiency are measured to ascertain whether they are within the warning and acceptance limits. (author).

  16. Fissile materials in solution concentration measured by active neutron interrogation

    International Nuclear Information System (INIS)

    Romeyer Dherbey, J.; Passard, Ch.; Cloue, J.; Bignan, G.

    1993-01-01

    The use of the active neutron interrogation to measure the concentration of plutonium contained in flow solutions is particularly interesting for fuel reprocessing plants. Indeed, this method gives a signal which is in a direct relation with the fissile materials concentration. Moreover, it is less sensitive to the gamma dose rate than the other nondestructive methods. Two measure methods have been evolved in CEA. Their principles are given into details in this work. The first one consists to detect fission delayed neutrons induced by a 252 Cf source. In the second one fission prompt neutrons induced by a neutron generator of 14 MeV are detected. (O.M.)

  17. PWFA plasma source - interferometric diagnostics for Li vapor density measurements

    International Nuclear Information System (INIS)

    Sivakumaran, V.; Mohandas, K.K.; Singh, Sneha; Ravi Kumar, A.V.

    2015-01-01

    A prototype (40 cm long) plasma source based on Li heat pipe oven has been developed for the Plasma Wakefield Acceleration (PWFA) experiments at IPR (IPR), Gujarat as a part of the ongoing Accelerator Programme. Li vapor in the oven is produced by heating solid Li in helium buffer gas. A uniform column of Li plasma is generated by UV photo ionization (193 nm) of the Li vapor in the heat pipe oven. In these experiments, an accurate measurement of Li vapor density is important as it has got a direct consequence on the plasma electron density. In the present experiment, the vapor density is measured optically by using Hook method (spectrally resolved white light interferometry). The hook like structure formed near the vicinity of the Li 670.8 nm resonance line was recorded with a white light Mach Zehnder interferometer crossed with an imaging spectrograph to estimate the Li vapor density. The vapor density measurements have been carried out as a function of external oven temperature and the He buffer gas pressure. This technique has the advantage of being insensitive to line broadening and line shape, and its high dynamic range even with optically thick absorption line. Here, we present the line integrated Lithium vapor density measurement using Hook method and also compare the same with other optical diagnostic techniques (White light absorption and UV absorption) for Li vapor density measurements. (author)

  18. A radioreceptor assay for measurement of plasma glucocorticoid binding activity

    International Nuclear Information System (INIS)

    Fan Jie

    1990-01-01

    A radioreceptor assay (RRA) for plasma glucocorticoid binding activity (GCBA) has been developed using glucocorticoid receptor in rat thymocytes. Unlike other assays for natural and certain synthetic corticosteroids, RRA measures the GCBA of all natural and synthetic GC in plasma. The range of standard curve was 0 ∼ 1.00 mg/L. The sensitivity was 0.01 mg/l. The recovery rate was 92.1%, and the intra and inter assay CV was 0.7% (n = 3) and 4.4% (n = 3) respectively. The level of corticosterone in 9 rat plasma samples was determined by RRA and CBG-isotope binding assay. There was a general correlation over a wide range between the values determined by the two assays (r = 0.95; P < 0.001). The measuring condition was described in detail

  19. From stellar plasmas to laboratory plasmas: application to X and XUV opacity measurements

    International Nuclear Information System (INIS)

    Loisel, G.

    2011-01-01

    The general context of this thesis is the one of radiative properties of high energy density matter. Energy densities involved (>10 11 J/cm 3 ) implies that a large part of energy exchange goes through radiation-matter interactions. My studies deal with spectral opacity, a fundamental parameter for modelling stellar interiors and constitute a propitious observable to experimental tests of theoretical descriptions of hot and dense plasmas physics. Although the main application of my work is stellar plasmas it can be useful for plasma diagnostics in inertial confinement fusion. My work activities are centred on the experimental study of opacities of plasmas at local thermodynamic equilibrium for temperature conditions of a few tens eV (a few 100000 K) and a few mg/cm 3 in matter density. Plasmas are obtained in conditions as homogenous as possible using the radiative heating of a laser-irradiated cavity. Heating is provided through a laser beam of high energy (100-300 J) and with relatively long pulse duration of a few nanosecond. For such measurements we could benefit from the LULI lasers configuration coupling the nanosecond beam with a picosecond one used to perform on a short duration the measurement of the plasma transmission. The use of short pulse laser to produce a short time radiography beam was a first achievement for this kind of experience. In the spectral range of keV photons, absorbing transitions 2p-3d or 3d-4f of elements of moderate or high atomic number have been probed. They present absorption structures which shape results mainly of the competition between spin-orbit splitting and statistical broadening effects. It appeared that this competition depends strongly on the atomic number Z. Thus for similar plasma parameters we explored opacities of Iron, Nickel, Copper and Germanium (Z around 30) in a first series of measurement and the one of Barium, Samarium and Gadolinium (Z around 60) in a second campaign

  20. Plasma shutdown device

    International Nuclear Information System (INIS)

    Hosogane, Nobuyuki; Nakayama, Takahide.

    1985-01-01

    Purpose: To prevent concentration of plasma currents to the plasma center upon plasma shutdown in a torus type thermonuclear device by the injection of fuels to the plasma center thereby prevent plasma disruption at the plasma center. Constitution: The plasma shutdown device comprises a plasma current measuring device that measures the current distribution of plasmas confined within a vacuum vessel and outputs a control signal for cooling the plasma center when the plasma currents concentrate to the plasma center and a fuel supply device that supplies fuels to the plasma center for cooling the center. The fuels are injected in the form of pellets into the plasmas. The direction and the velocity of the injection are set such that the pellets are ionized at the center of the plasmas. (Horiuchi, T.)