WorldWideScience

Sample records for plasma clinical-chemical parameters

  1. Typical parameters of the plasma chemical similarity in non-isothermal reactive plasmas

    International Nuclear Information System (INIS)

    Gundermann, S.; Jacobs, H.; Miethke, F.; Rutsher, A.; Wagner, H.E.

    1996-01-01

    The substance of physical similarity principles is contained in parameters which govern the comparison of different realizations of a model device. Because similarity parameters for non-isothermal plasma chemical reactors are unknown to a great extent, an analysis of relevant equations is given together with some experimental results. Modelling of the reactor and experimental results for the ozone synthesis are presented

  2. Titanium nitride plasma-chemical synthesis with titanium tetrachloride raw material in the DC plasma-arc reactor

    Science.gov (United States)

    Kirpichev, D. E.; Sinaiskiy, M. A.; Samokhin, A. V.; Alexeev, N. V.

    2017-04-01

    The possibility of plasmochemical synthesis of titanium nitride is demonstrated in the paper. Results of the thermodynamic analysis of TiCl4 - H2 - N2 system are presented; key parameters of TiN synthesis process are calculated. The influence of parameters of plasma-chemical titanium nitride synthesis process in the reactor with an arc plasmatron on characteristics on the produced powders is experimentally investigated. Structure, chemical composition and morphology dependencies on plasma jet enthalpy, stoichiometric excess of hydrogen and nitrogen in a plasma jet are determined.

  3. Quasi-equilibria and plasma chemical similarity in non-isothermal reactive plasmas

    International Nuclear Information System (INIS)

    Miethke, F.; Rutscher, A.; Wagner, H.E.

    2000-01-01

    With regard to the output of stable products the mode of operation of non-isothermal plasma chemical reactors shows physical and chemical well defined states, which represent limiting cases and may be interpreted as quasi-equilibrium states. The occurrence and the characteristics of these states, meanwhile more than once observed and described, are demonstrated by an instructive model reaction. Within the frame of the so-called Macroscopic Kinetics a central parameter is dominating the reactor operation. This result may be generalized and is linked up to the application of similarity principles for the reactor operation. After the general formulation of such principles, starting from the balance equations of particles and energy, a dimensionless similarity parameter is formulated, characterizing the composition of the effluent gas of the reactor. The applicability of this parameter is demonstrated by experimental examples. (Authors)

  4. Plasma-chemical processes and systems

    International Nuclear Information System (INIS)

    Castro B, J.

    1987-01-01

    The direct applications of plasma technology on chemistry and metallurgy are presented. The physical fundaments of chemically active non-equilibrium plasma, the reaction kinetics, and the physical chemical transformations occuring in the electrical discharges, which are applied in the industry, are analysed. Some plasma chemical systems and processes related to the energy of hydrogen, with the chemical technology and with the metallurgy are described. Emphasis is given to the optimization of the energy effectiveness of these processes to obtain reducers and artificial energetic carriers. (M.C.K.) [pt

  5. S-parameter at Non-Zero Temperature and Chemical Potential

    DEFF Research Database (Denmark)

    Søndergaard, Ulrik Ishøj; Sannino, Francesco; Pica, Claudio

    2011-01-01

    We compute the finite-temperature and matter density corrections to the S-parameter at the one loop level. At non-zero temperature T and matter density Lorentz symmetry breaks and therefore we suggest a suitable generalization of the S-parameter. By computing the plasma correction, we discover...... a reduction of the S-parameter in the physically relevant region of small external momenta for any non-zero chemical potential and T. In particular, the S-parameter vanishes at small m/T, where m is the mass of the fermions, due to the finite extent of the temporal direction. Our results are directly...

  6. A two-temperature chemical non-equilibrium modeling of DC arc plasma

    International Nuclear Information System (INIS)

    Qian Haiyang; Wu Bin

    2011-01-01

    To a better understanding of non-equilibrium characteristics of DC arc plasma,a two-dimensional axisymmetric two-temperature chemical non-equilibrium (2T-NCE) model is applied for direct current arc argon plasma generator with water-cooled constrictor at atmospheric pressure. The results show that the electron temperature and heavy particle temperature has a relationship under different working parameters, indicating that DC arc plasma has a strong non-equilibrium characteristic, and the variation is obvious. (authors)

  7. Oxygen Barrier Coating Deposited by Novel Plasma-enhanced Chemical Vapor Deposition

    DEFF Research Database (Denmark)

    Jiang, Juan; Benter, M.; Taboryski, Rafael Jozef

    2010-01-01

    We report the use of a novel plasma-enhanced chemical vapor deposition chamber with coaxial electrode geometry for the SiOx deposition. This novel plasma setup exploits the diffusion of electrons through the inner most electrode to the interior samples space as the major energy source. This confi......We report the use of a novel plasma-enhanced chemical vapor deposition chamber with coaxial electrode geometry for the SiOx deposition. This novel plasma setup exploits the diffusion of electrons through the inner most electrode to the interior samples space as the major energy source...... effect of single-layer coatings deposited under different reaction conditions was studied. The coating thickness and the carbon content in the coatings were found to be the critical parameters for the barrier property. The novel barrier coating was applied on different polymeric materials...

  8. The effect of axial ion parameters on the properties of glow discharge polymer in T2B/H2 plasma

    Science.gov (United States)

    Ai, Xing; He, Xiao-Shan; Huang, Jing-Lin; He, Zhi-Bing; Du, Kai; Chen, Guo

    2018-03-01

    Glow discharge polymer (GDP) films were fabricated using plasma-enhanced chemical vapor deposition. The main purpose of this work was to explore the correlations of plasma parameters with the surface morphology and chemical structure of GDP films. The intensities of main positive ions and ion energy as functions of axial distances in T2B/H2 plasma were diagnosed using energy-resolved mass spectrometry. The surface morphology and chemical structure were characterized as functions of axial distances using a scanning electron microscope and Fourier transform infrared spectroscopy, respectively. As the axial distance increases, both the intensities of positive ions and high energy ions decreases, and dissociation weakens while polymerization enhances. This leads to the weakening of the cross-linking structure of GDP films and the formation of dome defects on films. Additionally, high energy ions could introduce a strong etching effect to form etching pits. Therefore, an axial distance of about 20 mm was found to be the optimal plasma parameter to prepare the defect-free GDP films. These results could help one to find the optimal plasma parameters for GDP film deposition.

  9. Characterization of hot dense plasma with plasma parameters

    Science.gov (United States)

    Singh, Narendra; Goyal, Arun; Chaurasia, S.

    2018-05-01

    Characterization of hot dense plasma (HDP) with its parameters temperature, electron density, skin depth, plasma frequency is demonstrated in this work. The dependence of HDP parameters on temperature and electron density is discussed. The ratio of the intensities of spectral lines within HDP is calculated as a function of electron temperature. The condition of weakly coupled for HDP is verified by calculating coupling constant. Additionally, atomic data such as transition wavelength, excitation energies, line strength, etc. are obtained for Be-like ions on the basis of MCDHF method. In atomic data calculations configuration interaction and relativistic effects QED and Breit corrections are newly included for HDP characterization and this is first result of HDP parameters from extreme ultraviolet (EUV) radiations.

  10. DAQ system for low density plasma parameters measurement

    International Nuclear Information System (INIS)

    Joshi, Rashmi S.; Gupta, Suryakant B.

    2015-01-01

    In various cases where low density plasmas (number density ranges from 1E4 to 1E6 cm -3 ) exist for example, basic plasma studies or LEO space environment measurement of plasma parameters becomes very critical. Conventional tip (cylindrical) Langmuir probes often result into unstable measurements in such lower density plasma. Due to larger surface area, a spherical Langmuir probe is used to measure such lower plasma densities. Applying a sweep voltage signal to the probe and measuring current values corresponding to these voltages gives V-I characteristics of plasma which can be plotted on a digital storage oscilloscope. This plot is analyzed for calculating various plasma parameters. The aim of this paper is to measure plasma parameters using a spherical Langmuir probe and indigenously developed DAQ system. DAQ system consists of Keithley source-meter and a host system connected by a GPIB interface. An online plasma parameter diagnostic system is developed for measuring plasma properties for non-thermal plasma in vacuum. An algorithm is developed using LabVIEW platform. V-I characteristics of plasma are plotted with respect to different filament current values and different locations of Langmuir probe with reference to plasma source. V-I characteristics is also plotted for forward and reverse voltage sweep generated programmatically from the source meter. (author)

  11. Sensitivity of transient synchrotron radiation to tokamak plasma parameters

    International Nuclear Information System (INIS)

    Fisch, N.J.; Kritz, A.H.

    1988-12-01

    Synchrotron radiation from a hot plasma can inform on certain plasma parameters. The dependence on plasma parameters is particularly sensitive for the transient radiation response to a brief, deliberate, perturbation of hot plasma electrons. We investigate how such a radiation response can be used to diagnose a variety of plasma parameters in a tokamak. 18 refs., 13 figs

  12. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  13. Assessment of thermodynamic parameters of plasma shock wave

    International Nuclear Information System (INIS)

    Vasileva, O V; Isaev, Yu N; Budko, A A; Filkov, A I

    2014-01-01

    The work is devoted to the solution of the one-dimensional equation of hydraulic gas dynamics for the coaxial magneto plasma accelerator by means of Lax-Wendroff modified algorithm with optimum choice of the regularization parameter artificial viscosity. Replacement of the differential equations containing private derivatives is made by finite difference method. Optimum parameter of regularization artificial viscosity is added using the exact known decision of Soda problem. The developed algorithm of thermodynamic parameter calculation in a braking point is proved. Thermodynamic parameters of a shock wave in front of the plasma piston of the coaxial magneto plasma accelerator are calculated on the basis of the offered algorithm. Unstable high-frequency fluctuations are smoothed using modeling and that allows narrowing the ambiguity area. Results of calculation of gas dynamic parameters in a point of braking coincide with literary data. The chart 3 shows the dynamics of change of speed and thermodynamic parameters of a shock wave such as pressure, density and temperature just before the plasma piston

  14. On improved understanding of plasma-chemical processes in complex low-temperature plasmas

    Science.gov (United States)

    Röpcke, Jürgen; Loffhagen, Detlef; von Wahl, Eric; Nave, Andy S. C.; Hamann, Stephan; van Helden, Jean-Piere H.; Lang, Norbert; Kersten, Holger

    2018-05-01

    Over the last years, chemical sensing using optical emission spectroscopy (OES) in the visible spectral range has been combined with methods of mid infrared laser absorption spectroscopy (MIR-LAS) in the molecular fingerprint region from 3 to 20 μm, which contains strong rotational-vibrational absorption bands of a large variety of gaseous species. This optical approach established powerful in situ diagnostic tools to study plasma-chemical processes of complex low-temperature plasmas. The methods of MIR-LAS enable to detect stable and transient molecular species in ground and excited states and to measure the concentrations and temperatures of reactive species in plasmas. Since kinetic processes are inherent to discharges ignited in molecular gases, high time resolution on sub-second timescales is frequently desired for fundamental studies as well as for process monitoring in applied research and industry. In addition to high sensitivity and good temporal resolution, the capacity for broad spectral coverage enabling multicomponent detection is further expanding the use of OES and MIR-LAS techniques. Based on selected examples, this paper reports on recent achievements in the understanding of complex low-temperature plasmas. Recently, a link with chemical modeling of the plasma has been provided, which is the ultimate objective for a better understanding of the chemical and reaction kinetic processes occurring in the plasma. Contribution to the Topical Issue "Fundamentals of Complex Plasmas", edited by Jürgen Meichsner, Michael Bonitz, Holger Fehske, Alexander Piel.

  15. A solid-state nuclear magnetic resonance study of post-plasma reactions in organosilicone microwave plasma-enhanced chemical vapor deposition (PECVD) coatings.

    Science.gov (United States)

    Hall, Colin J; Ponnusamy, Thirunavukkarasu; Murphy, Peter J; Lindberg, Mats; Antzutkin, Oleg N; Griesser, Hans J

    2014-06-11

    Plasma-polymerized organosilicone coatings can be used to impart abrasion resistance and barrier properties to plastic substrates such as polycarbonate. Coating rates suitable for industrial-scale deposition, up to 100 nm/s, can be achieved through the use of microwave plasma-enhanced chemical vapor deposition (PECVD), with optimal process vapors such as tetramethyldisiloxane (TMDSO) and oxygen. However, it has been found that under certain deposition conditions, such coatings are subject to post-plasma changes; crazing or cracking can occur anytime from days to months after deposition. To understand the cause of the crazing and its dependence on processing plasma parameters, the effects of post-plasma reactions on the chemical bonding structure of coatings deposited with varying TMDSO-to-O2 ratios was studied with (29)Si and (13)C solid-state magic angle spinning nuclear magnetic resonance (MAS NMR) using both single-pulse and cross-polarization techniques. The coatings showed complex chemical compositions significantly altered from the parent monomer. (29)Si MAS NMR spectra revealed four main groups of resonance lines, which correspond to four siloxane moieties (i.e., mono (M), di (D), tri (T), and quaternary (Q)) and how they are bound to oxygen. Quantitative measurements showed that the ratio of TMDSO to oxygen could shift the chemical structure of the coating from 39% to 55% in Q-type bonds and from 28% to 16% for D-type bonds. Post-plasma reactions were found to produce changes in relative intensities of (29)Si resonance lines. The NMR data were complemented by Fourier transform infrared (FTIR) spectroscopy. Together, these techniques have shown that the bonding environment of Si is drastically altered by varying the TMDSO-to-O2 ratio during PECVD, and that post-plasma reactions increase the cross-link density of the silicon-oxygen network. It appears that Si-H and Si-OH chemical groups are the most susceptible to post-plasma reactions. Coatings produced at a

  16. Calculation of stationary plasma parameters in an electromagnetic trap

    International Nuclear Information System (INIS)

    Karpukhin, V.I.; Lavrent'ev, O.A.; Sappa, N.N.

    1978-01-01

    The model of energy and particle balance is considered and the numerical calculations for stationary plasma parameters, supported by the electron injection, are obtained for a hypothetical electromagnetic trap with linear dimensions, magnetic field strength and energy contribution to plasma of the order of these parameters for the modern tokamak-type traps. The process of limitation of an effective injection current and energy contribution to plasma caused by returning of electrons to the injector due to diffusion in the velocity space is simulated. In approximation of a classical diffusion dependences are obtained of the effective energy contribution to plasma and of the parameters ntausub(E) and Tsub(i) (n is a plasma density; tausub(E)- energetic lifetime; Tsub(i) ion temperature) on electron injection current and power and on the confining magnetic field strength. It had been established that at classical character of diffusion in electromagnetic trap with above parameters one could obtain stationary plasma with ntausub(E)=10 12 cm -3 s and Tsub(i)=1keV, maintaining only by electron injection

  17. Fast determination of plasma parameters through function parametrization

    International Nuclear Information System (INIS)

    Braams, B.J.; Jilge, W.; Lackner, K.

    1985-09-01

    The method of function parametrization, developed by H. Wind for fast data evaluation in high energy physics, is demonstrated in the context of controlled fusion research. This method relies on a statistical analysis of a large data base of simulated experiments in order to obtain a functional representation for intrinsic physical parameters of a system in terms of the values of the measurements. Rapid determination of characteristic equilibrium parameters of a tokamak discharge is shown to be a particularly indicated application. The method is employed on the ASDEX experiment to determine the following parameters of the plasma: position of the magnetic axis, geometric center, and current center; minor radius, elongation, and area of the plasma column; a normalized safety factor at the plasma boundary; the Shafranov parameter βsub(p)+lsub(i)/2; the flux difference between the plasma boundary and an external reference value; the position of the lower and upper saddle points, and the intersections of the separatrix with the four divertor plates. The relevant measurements consist of three differential poloidal flux measurements, four poloidal field measurements, the current through the multipole shaping coils, and the total plasma current. Function parametrization supplies a very accurate interpretation of these data, which is now used for online data analysis, and is also sufficiently fast to be suitable for real-time control of the plasma. (orig.)

  18. Combustion flame-plasma hybrid reactor systems, and chemical reactant sources

    Science.gov (United States)

    Kong, Peter C

    2013-11-26

    Combustion flame-plasma hybrid reactor systems, chemical reactant sources, and related methods are disclosed. In one embodiment, a combustion flame-plasma hybrid reactor system comprising a reaction chamber, a combustion torch positioned to direct a flame into the reaction chamber, and one or more reactant feed assemblies configured to electrically energize at least one electrically conductive solid reactant structure to form a plasma and feed each electrically conductive solid reactant structure into the plasma to form at least one product is disclosed. In an additional embodiment, a chemical reactant source for a combustion flame-plasma hybrid reactor comprising an elongated electrically conductive reactant structure consisting essentially of at least one chemical reactant is disclosed. In further embodiments, methods of forming a chemical reactant source and methods of chemically converting at least one reactant into at least one product are disclosed.

  19. Influence of Chemical Precleaning on the Plasma Treatment Efficiency of Aluminum by RF Plasma Pencil

    International Nuclear Information System (INIS)

    Prysiazhnyi, Vadym; Slavicek, Pavel; Klima, Milos; Mikmekova, Eliska

    2016-01-01

    This paper is aimed to show the influence of initial chemical pretreatment prior to subsequent plasma activation of aluminum surfaces. The results of our study showed that the state of the topmost surface layer (i.e. the surface morphology and chemical groups) of plasma modified aluminum significantly depends on the chemical precleaning. Commonly used chemicals (isopropanol, trichlorethane, solution of NaOH in deionized water) were used as precleaning agents. The plasma treatments were done using a radio frequency driven atmospheric pressure plasma pencil developed at Masaryk University, which operates in Ar, Ar/O 2 gas mixtures. The effectiveness of the plasma treatment was estimated by the wettability measurements, showing high wettability improvement already after 0.3 s treatment. The effects of surface cleaning (hydrocarbon removal), surface oxidation and activation (generation of OH groups) were estimated using infrared spectroscopy. The changes in the surface morphology were measured using scanning electron microscopy. Optical emission spectroscopy measurements in the near-to-surface region with temperature calculations showed that plasma itself depends on the sample precleaning procedure. (paper)

  20. Influence of Chemical Precleaning on the Plasma Treatment Efficiency of Aluminum by RF Plasma Pencil

    Science.gov (United States)

    Vadym, Prysiazhnyi; Pavel, Slavicek; Eliska, Mikmekova; Milos, Klima

    2016-04-01

    This paper is aimed to show the influence of initial chemical pretreatment prior to subsequent plasma activation of aluminum surfaces. The results of our study showed that the state of the topmost surface layer (i.e. the surface morphology and chemical groups) of plasma modified aluminum significantly depends on the chemical precleaning. Commonly used chemicals (isopropanol, trichlorethane, solution of NaOH in deionized water) were used as precleaning agents. The plasma treatments were done using a radio frequency driven atmospheric pressure plasma pencil developed at Masaryk University, which operates in Ar, Ar/O2 gas mixtures. The effectiveness of the plasma treatment was estimated by the wettability measurements, showing high wettability improvement already after 0.3 s treatment. The effects of surface cleaning (hydrocarbon removal), surface oxidation and activation (generation of OH groups) were estimated using infrared spectroscopy. The changes in the surface morphology were measured using scanning electron microscopy. Optical emission spectroscopy measurements in the near-to-surface region with temperature calculations showed that plasma itself depends on the sample precleaning procedure.

  1. Effects of biometrics, location and persistent organic pollutants on blood clinical-chemical parameters in polar bears (Ursus maritimus) from Svalbard, Norway.

    Science.gov (United States)

    Ciesielski, Tomasz Maciej; Sonne, Christian; Ormbostad, Ingunn; Aars, Jon; Lie, Elisabeth; Bytingsvik, Jenny; Jenssen, Bjørn Munro

    2018-05-31

    In the present study, blood clinical-chemical parameters (BCCPs) were analysed in 20 female and 18 male Svalbard polar bears (Ursus maritimus) captured in spring 2007. The aim was to study how age, body condition (BC), biometrics, plasma lipid content and geographical location may confound the relationship between persistent organic pollutants (POPs) including PCBs, HCB, chlordanes, DDTs, HCHs, mirex and OH-PCBs and the concentrations of 12 specific BCCPs (hematocrit [HCT], hemoglobin [HB], aspartate aminotransferase [ASAT], alanine aminotransferase [ALAT], γ-glutamyltransferase [GGT], creatine kinase [CK], triglycerides [TG], cholesterol [CHOL], high-density lipoprotein [HDL], creatinine (CREA], urea, potassium (K]), and to investigate if any of these BCCPs may be applied as potential biomarkers for POP exposure in polar bears. Initial PCA and O-PLS modelling showed that age, lipids, BC and geographical location (longitude and latitude) were important parameters explaining BCCPs in females. Following subsequent partial correlation analyses correcting for age and lipids, multiple POPs in females were still significantly correlated with HCT and HDL (all p biometrics, lipids and longitude in males, multiple POPs were significantly correlated with HCT, ASAT, GGT and CHOL (all p < 0.05). In conclusion, several confounding parameters has to be taken into account when studying the relations between BCCPs and POPs in polar bears. When correcting for these, in particular HCT may be used as a simple cost-efficient biomarker of POP exposure in polar bears. Furthermore, decreasing HDL concentrations and increasing CHOL concentration with increasing POP concentrations may indicate responses related to increased risk of cardiovascular disease. We therefore suggest to further study POP exposure and lipidome response to increase knowledge of the risk of cardiometabolic syndrome in polar bears. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Effect of Equilibrium Flow on Plasma Parameters

    International Nuclear Information System (INIS)

    Mukhopadhyay, S.; Lahiri, S.; Sakanaka, P.H.; Dasgupta, B.

    2003-01-01

    The transition to high confinement modes have been identified with the occurrence of strong shear flow near the plasma boundary. Plasma flow has also been associated with various instabilities, heating and other physical processes. As a result, it has become very important to study the effect of such flows on various plasma parameters. In this paper, we present the numerical solution of plasma equilibrium with incompressible toroidal and poloidal flows in several magnetic confinement configurations including tokamaks. The code, which was reported in the last conference, has been used to solve the problem in both circular and D-shaped devices. A parametric study on the generation of shear flow due to radial electric fields has been carried out. Through this study, it has been possible to generate plasma equilibria having sharp pressure gradients which are remarkably close to those reported in various H-mode experiments. The effects of flow on reverse shear equilibria and on the position of the magnetic axis has been studied. Finally, a detailed study has been carried out to understand the effect of flows on important plasma parameters, such as the poloidal flux function, β, energy confinement time

  3. Fundamental aspects of plasma chemical physics Thermodynamics

    CERN Document Server

    Capitelli, Mario; D'Angola, Antonio

    2012-01-01

    Fundamental Aspects of Plasma Chemical Physics - Thermodynamics develops basic and advanced concepts of plasma thermodynamics from both classical and statistical points of view. After a refreshment of classical thermodynamics applied to the dissociation and ionization regimes, the book invites the reader to discover the role of electronic excitation in affecting the properties of plasmas, a topic often overlooked by the thermal plasma community. Particular attention is devoted to the problem of the divergence of the partition function of atomic species and the state-to-state approach for calculating the partition function of diatomic and polyatomic molecules. The limit of ideal gas approximation is also discussed, by introducing Debye-Huckel and virial corrections. Throughout the book, worked examples are given in order to clarify concepts and mathematical approaches. This book is a first of a series of three books to be published by the authors on fundamental aspects of plasma chemical physics.  The next bo...

  4. Wave propagation in a quasi-chemical equilibrium plasma

    Science.gov (United States)

    Fang, T.-M.; Baum, H. R.

    1975-01-01

    Wave propagation in a quasi-chemical equilibrium plasma is studied. The plasma is infinite and without external fields. The chemical reactions are assumed to result from the ionization and recombination processes. When the gas is near equilibrium, the dominant role describing the evolution of a reacting plasma is played by the global conservation equations. These equations are first derived and then used to study the small amplitude wave motion for a near-equilibrium situation. Nontrivial damping effects have been obtained by including the conduction current terms.

  5. Measurement of performance parameters of plasma source for plasma opening switch on Qiangguang-Ⅰ generator

    International Nuclear Information System (INIS)

    Luo Weixi; Zeng Zhengzhong; Lei Tianshi; Wang Liangping; Hu Yixiang; Sun Tieping; Huang Tao

    2012-01-01

    The plasma source (cable guns) of the plasma opening switch (POS) on Qiangguang Ⅰ generator was chosen as the study object. The plasma source performance was investigated by using charge collectors. Experimental results show that the plasma ejection density is positively correlated with the structural parameter, the distance between gun core tip and muzzle plane, and the plasma ejection velocity is negatively correlated with the parameter. The increasing rate of plasma ejection density is less than that of drive current. As far as a plasma source with tens of cable plasma guns is concerned, the influence of single cable gun's discharge dispersancy on plasma uniformity is little. Analysis of uncertainty shows that the uncertainty of measurement can be reduced by increasing the number of experiments and averaging the results. The combined standard uncertainty of plasma ejection density is less than 10%. (authors)

  6. Microwave plasma-enhanced chemical vapour deposition growth of carbon nanostructures

    Directory of Open Access Journals (Sweden)

    Shivan R. Singh

    2010-05-01

    Full Text Available The effect of various input parameters on the production of carbon nanostructures using a simple microwave plasma-enhanced chemical vapour deposition technique has been investigated. The technique utilises a conventional microwave oven as the microwave energy source. The developed apparatus is inexpensive and easy to install and is suitable for use as a carbon nanostructure source for potential laboratory-based research of the bulk properties of carbon nanostructures. A result of this investigation is the reproducibility of specific nanostructures with the variation of input parameters, such as carbon-containing precursor and support gas flow rate. It was shown that the yield and quality of the carbon products is directly controlled by input parameters. Transmission electron microscopy and scanning electron microscopy were used to analyse the carbon products; these were found to be amorphous, nanotubes and onion-like nanostructures.

  7. Strangeness chemical equilibration in a quark-gluon plasma

    International Nuclear Information System (INIS)

    Letessier, Jean; Rafelski, Johann

    2007-01-01

    We study, in the dynamically evolving quark-gluon plasma (QGP) fireball formed in relativistic heavy ion collisions at the BNL Relativistic Heavy Ion Collider (RHIC) and CERN Large Hadron Collider (LHC), the growth of strangeness yield toward and beyond the chemical equilibrium. We account for the contribution of the direct strangeness production and evaluate the thermal-QCD strangeness production mechanisms. The specific yield of strangeness per entropy, s/S, is the primary target variable. We explore the effect of collision impact parameter, i.e., fireball size, on kinetic strangeness chemical equilibration in QGP. Insights gained in studying the RHIC data with regard to the dynamics of the fireball are applied to the study of strangeness production at the LHC. We use these results and consider the strange hadron relative particle yields at RHIC and LHC in a systematic fashion. We consider both the dependence on s/S and the direct dependence on the participant number

  8. Fast determination of plasma parameters

    International Nuclear Information System (INIS)

    Wijnands, T.J.; Parlange, F.; Joffrin, E.

    1995-01-01

    Fast analysis of diagnostic signals of a tokamak discharge is demonstrated by using 4 fundamentally different techniques. A comparison between Function Parametrization (FP), Canonical Correlation Analysis (CCA) and a particular Neural Network (NN) configuration known as the Multi Layer Perceptron (MLP) is carried out, thereby taking a unique linear model based on a Singular Value Decomposition (SVD) as a reference. The various techniques provide all functional representations of characteristic plasma parameters in terms of the values of the measurements and are based on an analysis of a large, experimentally achieved database. A brief mathematical description of the various techniques is given, followed by two particular applications to Tore Supra diagnostic data. The first problem is concerned with the identification of the plasma boundary parameters using the poloidal field and differential poloidal flux measurements. A second application involves the interpretation of line integrated data from the multichannel interfero-polarimeter to obtain the central value of the safety factor. (author) 4 refs.; 3 figs

  9. Strangeness Production in a Chemically Equilibrating Quark-Gluon Plasma

    Institute of Scientific and Technical Information of China (English)

    HE Ze-Jun; LONG Jia-Li; MA Yu-Gang; MA Guo-Liang

    2004-01-01

    @@ We study the strangeness of a chemically equilibrating quark-gluon plasma at finite baryon density based on the and will accelerate with the change of the initial system from a chemically non-equilibrated to an equilibrated system. We also find that the calculated strangeness is very different from the one in the thermodynamic equilibrium system. This study may be helpful to understand the formation of quark-gluon plasma via a chemically non-equilibrated evolution framework.

  10. Plasma Assisted Chemical Vapour Deposition – Technological Design Of Functional Coatings

    Directory of Open Access Journals (Sweden)

    Januś M.

    2015-06-01

    Full Text Available Plasma Assisted Chemical Vapour Deposition (PA CVD method allows to deposit of homogeneous, well-adhesive coatings at lower temperature on different substrates. Plasmochemical treatment significantly impacts on physicochemical parameters of modified surfaces. In this study we present the overview of the possibilities of plasma processes for the deposition of diamond-like carbon coatings doped Si and/or N atoms on the Ti Grade2, aluminum-zinc alloy and polyetherketone substrate. Depending on the type of modified substrate had improved the corrosion properties including biocompatibility of titanium surface, increase of surface hardness with deposition of good adhesion and fine-grained coatings (in the case of Al-Zn alloy and improving of the wear resistance (in the case of PEEK substrate.

  11. Blood plasma clinical-chemical parameters as biomarker endpoints for organohalogen contaminant exposure in Norwegian raptor nestlings

    DEFF Research Database (Denmark)

    Sonne, Christian; Bustnes, Jan O.; Herzke, Dorte

    2012-01-01

    Raptors are exposed to biomagnifying and toxic organohalogenated compounds (OHCs) such as organochlorines, brominated flame retardants and perfluorinated compounds. To investigate how OHC exposure may affect biochemical pathways we collected blood plasma from Norwegian northern goshawk (n=56...... it is uncertain if such changes have any health effects. The OHC concentrations were below concentrations causing reproductive toxicity in adults of other raptor species but similar to those of concern for endocrine disruption of thyroid hormones in e.g., bald eagles....

  12. Some parameters of uranium hexafluoride plasma produced by products of nuclear reaction

    International Nuclear Information System (INIS)

    Batyrbekov, G.A.; Belyakova, Eh.A.

    1996-01-01

    The probe experimental results of investigation of uranium hexafluoride plasma produced in the centre of nuclear reactor core were demonstrated. Study of uranium hexafluoride plasma is continued by the following reasons: a possibility of U F 6 utilization as nuclear fuel, the utilization of U F 6 as volume source o ionization, search of active laser media compatible with U F 6 that is complicated by lack of constant rates data for most of plasma-chemical reactions with U F 6 and his dissociation products. Cylindrical probe volt-ampere characteristics (VAC) measured in U F 6 plasma at pressure 20 Torr and different thermal neutron fluxes and have following features: -firstly, it is possible to choose a linear part in the field of small positive potentials of probe (0-1) V; - secondary, ion branches of VAC have typical break which current of satiation corresponds to; -thirdly, probe VAC measured at small values of thermal neutron flux density are symmetrical. Diagnostics approaches were used for interpretation VAC of probe. The values of satiation current and linear part of electron branch were calculated, and such plasma parameters as conductivity, diffusion coefficient values of positive and negative ions were determined. The resonance recharge cross section was estimated on diffusion coefficient value

  13. Drag force in strongly coupled, anisotropic plasma at finite chemical potential

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Somdeb; Haque, Najmul [Theory Division, Saha Institute of Nuclear Physics,1/AF Bidhannagar, Kolkata-700 064 (India)

    2014-12-30

    We employ methods of gauge/string duality to analyze the drag force on a heavy quark moving through a strongly coupled, anisotropic N=4,SU(N) super Yang-Mills plasma in the presence of a finite U(1) chemical potential. We present numerical results valid for any value of the anisotropy parameter and the U(1) charge density and arbitrary direction of the quark velocity with respect to the direction of anisotropy. In the small anisotropy limit we are also able to furnish analytical results.

  14. Polyethylene Oxide Films Polymerized by Radio Frequency Plasma-Enhanced Chemical Vapour Phase Deposition and Its Adsorption Behaviour of Platelet-Rich Plasma

    International Nuclear Information System (INIS)

    Wen-Juan, Hu; Fen-Yan, Xie; Qiang, Chen; Jing, Weng

    2008-01-01

    We present polyethylene oxide (PEO) functional films polymerized by rf plasma-enhanced vapour chemical deposition (rf-PECVD) on p-Si (100) surface with precursor ethylene glycol dimethyl ether (EGDME) and diluted Ar in pulsed plasma mode. The influences of discharge parameters on the film properties and compounds are investigated. The film structure is analysed by Fourier transform infrared (FTIR) spectroscopy. The water contact angle measurement and atomic force microscope (AFM) are employed to examine the surface polarity and to detect surface morphology, respectively. It is concluded that the smaller duty cycle in pulsed plasma mode contributes to the rich C-O-C (EO) group on the surfaces. As an application, the adsorption behaviour of platelet-rich plasma on plasma polymerization films performed in-vitro is explored. The shapes of attached cells are studied in detail by an optic invert microscope, which clarifies that high-density C-O-C groups on surfaces are responsible for non-fouling adsorption behaviour of the PEO films

  15. Polyethylene Oxide Films Polymerized by Radio Frequency Plasma-Enhanced Chemical Vapour Phase Deposition and Its Adsorption Behaviour of Platelet-Rich Plasma

    Science.gov (United States)

    Hu, Wen-Juan; Xie, Fen-Yan; Chen, Qiang; Weng, Jing

    2008-10-01

    We present polyethylene oxide (PEO) functional films polymerized by rf plasma-enhanced vapour chemical deposition (rf-PECVD) on p-Si (100) surface with precursor ethylene glycol dimethyl ether (EGDME) and diluted Ar in pulsed plasma mode. The influences of discharge parameters on the film properties and compounds are investigated. The film structure is analysed by Fourier transform infrared (FTIR) spectroscopy. The water contact angle measurement and atomic force microscope (AFM) are employed to examine the surface polarity and to detect surface morphology, respectively. It is concluded that the smaller duty cycle in pulsed plasma mode contributes to the rich C-O-C (EO) group on the surfaces. As an application, the adsorption behaviour of platelet-rich plasma on plasma polymerization films performed in-vitro is explored. The shapes of attached cells are studied in detail by an optic invert microscope, which clarifies that high-density C-O-C groups on surfaces are responsible for non-fouling adsorption behaviour of the PEO films.

  16. Two dimensional radial gas flows in atmospheric pressure plasma-enhanced chemical vapor deposition

    Science.gov (United States)

    Kim, Gwihyun; Park, Seran; Shin, Hyunsu; Song, Seungho; Oh, Hoon-Jung; Ko, Dae Hong; Choi, Jung-Il; Baik, Seung Jae

    2017-12-01

    Atmospheric pressure (AP) operation of plasma-enhanced chemical vapor deposition (PECVD) is one of promising concepts for high quality and low cost processing. Atmospheric plasma discharge requires narrow gap configuration, which causes an inherent feature of AP PECVD. Two dimensional radial gas flows in AP PECVD induces radial variation of mass-transport and that of substrate temperature. The opposite trend of these variations would be the key consideration in the development of uniform deposition process. Another inherent feature of AP PECVD is confined plasma discharge, from which volume power density concept is derived as a key parameter for the control of deposition rate. We investigated deposition rate as a function of volume power density, gas flux, source gas partial pressure, hydrogen partial pressure, plasma source frequency, and substrate temperature; and derived a design guideline of deposition tool and process development in terms of deposition rate and uniformity.

  17. Investigation of the helicon discharge plasma parameters in a hybrid RF plasma system

    International Nuclear Information System (INIS)

    Aleksandrov, A. F.; Petrov, A. K.; Vavilin, K. V.; Kralkina, E. A.; Neklyudova, P. A.; Nikonov, A. M.; Pavlov, V. B.; Ayrapetov, A. A.; Odinokov, V. V.; Sologub, V. A.; Pavlov, G. Ya.

    2016-01-01

    Results of an experimental study of the helicon discharge plasma parameters in a prototype of a hybrid RF plasma system equipped with a solenoidal antenna are described. It is shown that an increase in the external magnetic field leads to the formation of a plasma column and a shift of the maximum ion current along the discharge axis toward the bottom flange of the system. The shape of the plasma column can be controlled via varying the configuration of the magnetic field.

  18. Investigation of the helicon discharge plasma parameters in a hybrid RF plasma system

    Energy Technology Data Exchange (ETDEWEB)

    Aleksandrov, A. F.; Petrov, A. K., E-mail: alpetrov57@gmail.com; Vavilin, K. V.; Kralkina, E. A.; Neklyudova, P. A.; Nikonov, A. M.; Pavlov, V. B. [Moscow State University, Faculty of Physics (Russian Federation); Ayrapetov, A. A.; Odinokov, V. V.; Sologub, V. A.; Pavlov, G. Ya. [Research Institute of Precision Engineering (Russian Federation)

    2016-03-15

    Results of an experimental study of the helicon discharge plasma parameters in a prototype of a hybrid RF plasma system equipped with a solenoidal antenna are described. It is shown that an increase in the external magnetic field leads to the formation of a plasma column and a shift of the maximum ion current along the discharge axis toward the bottom flange of the system. The shape of the plasma column can be controlled via varying the configuration of the magnetic field.

  19. Optimization of plasma flow parameters of the magnetoplasma compressor

    International Nuclear Information System (INIS)

    Dojcinovic, I P; Kuraica, M M; Obradovc, B M; Cvetanovic, N; Puric, J

    2007-01-01

    Optimization of the working conditions of the magnetoplasma compressor (MPC) has been performed through analysing discharge and compression plasma flow parameters in hydrogen, nitrogen and argon at different pressures. Energy conversion rate, volt-ampere curve exponent and plasma flow velocities have been studied to optimize the efficiency of energy transfer from the supply source to the plasma. It has been found that the most effective energy transfer from the supply to the plasma is in hydrogen as a working gas at 1000 Pa pressure. It was found that the accelerating regime exists for hydrogen up to 3000 Pa pressures, in nitrogen up to 2000 Pa and in argon up to 1000 Pa pressure. At higher pressures MPC in all the gases works in the decelerating regime. At pressures lower than 200 Pa, high cathode erosion is observed. MPC plasma flow parameter optimization is very important because this plasma accelerating system may be of special interest for solid surface modification and other technology applications

  20. Investigation of helium plasma stream parameters in experiments on surface modification

    International Nuclear Information System (INIS)

    Bandura, A.N.; Byrka, O.V.; Chebotarev, V.V.; Garkusha, I.E.; Tsarenko, A.V. and eds.

    2005-01-01

    The main objection of this study is adjustment of plasma treatment regimes for different materials that allows achieving optimal thickness of modified layer with simultaneously minimal value of surface roughness. With use of optical spectroscopy, detailed information about the basic plasma parameters - electron density, electron and ion temperatures, plasma stream duration and velocity, was obtained. Integrated spectra of plasma radiation were analyzed. The majority of helium and impurity spectral lines were investigated on a subject of Stark broadening. Plasma pressure and energy density values measured with piezodetectors and calorimeters are in good agreement with plasma parameters obtained by optical techniques

  1. Dependence of plasma characteristics on dc magnetron sputter parameters

    International Nuclear Information System (INIS)

    Wu, S.Z.

    2005-01-01

    Plasma discharge characteristics of a dc magnetron system were measured by a single Langmuir probe at the center axis of the dual-side process chamber. Plasma potential, floating potential, electron and ion densities, and electron temperature were extracted with varying dc power and gas pressure during sputter deposition of a metal target; strong correlations were shown between these plasma parameters and the sputter parameters. The electron density was controlled mostly by secondary electron generation in constant power mode, while plasma potential reflects the confinement space variation due to change of discharge voltage. When discharge pressure was varied, plasma density increases with the increased amount of free stock molecules, while electron temperature inversely decreased, due to energy-loss collision events. In low-pressure discharges, the electron energy distribution function measurements show more distinctive bi-Maxwellian distribution, with the fast electron temperature gradually decreases with increased gas pressure

  2. Atmospheric Pressure Plasma Induced Sterilization and Chemical Neutralization

    Science.gov (United States)

    Garate, Eusebio; Evans, Kirk; Gornostaeva, Olga; Alexeff, Igor; Lock Kang, Weng; Wood, Thomas K.

    1998-11-01

    We are studying chemical neutralization and surface decontamination using atmospheric pressure plasma discharges. The plasma is produced by corona discharge from an array of pins and a ground plane. The array is constructed so that various gases, like argon or helium, can be flowed past the pins where the discharge is initiated. The pin array can be biased using either DC, AC or pulsed discharges. Results indicate that the atmospheric plasma is effective in sterilizing surfaces with biological contaminants like E-coli and bacillus subtilus cells. Exposure times of less than four minutes in an air plasma result in a decrease in live colony counts by six orders of magnitude. Greater exposure times result in a decrease of live colony counts of up to ten orders of magnitude. The atmospheric pressure discharge is also effective in decomposing organic phosphate compounds that are simulants for chemical warfare agents. Details of the decomposition chemistry, by-product formation, and electrical energy consumption of the system will be discussed.

  3. BOVINE PLASMA FIBRINOGEN AS MARKER IN CLINICAL AND SUB-CLINICAL MASTITIS

    Directory of Open Access Journals (Sweden)

    R. Ali

    2018-06-01

    Full Text Available Plasma samples were collected from healthy as well as clinical and sub-clinical mastitis affected cows from Barasat, West Bengal, India. Plasma samples, after ammonium sulphate precipitation, were dialyzed against several changes of PBS (pH 7.2 to remove the excess ammonium sulphate. Then plasma fibrinogens were purified by gel filtration chromatography on Sephacryl S-200 HR. SDS-PAGE (10% of purified fibrinogen from plasma of healthy cow revealed polypeptide bands of 74, 67 and 57 kDa which represent the α (alpha, β (beta and γ (gamma- chains respectively. On the other hand, purified fibrinogen from plasma of sub-clinical and clinical mastitis affected cow revealed polypeptide bands of 73 (α-chain, 68 kDa (β-chain and 72 (γ-chain, 68 kDa (β-chain respectively. The SDS-PAGE analysis showed the absence of gamma (γ- chain of fibrinogen in both the samples of sub-clinical and clinical mastitis positive cow. Single precipitin line was observed in double immunodiffusion test when purified fibrinogen from healthy, clinical and subclinical mastitis positive cows reacted with hyper immune sera raised in rabbit. No precipitin line was found against the normal control serum. These purified fibrinogens also showed cross reactivity against antibody raised in rabbit when analyzed by western blot technique.

  4. Sensing signatures mediated by chemical structure of molecular solids in laser-induced plasmas.

    Science.gov (United States)

    Serrano, Jorge; Moros, Javier; Laserna, J Javier

    2015-03-03

    Laser ablation of organic compounds has been investigated for almost 30 years now, either in the framework of pulse laser deposition for the assembling of new materials or in the context of chemical sensing. Various monitoring techniques such as atomic and molecular fluorescence, time-of-flight mass spectrometry, and optical emission spectroscopy have been used for plasma diagnostics in an attempt to understand the spectral signature and potential origin of gas-phase ions and fragments from organic plasmas. Photochemical and photophysical processes occurring within these systems are generally much more complex than those suggested by observation of optical emission features. Together with laser ablation parameters, the structural and chemical-physical properties of molecules seem to be closely tied to the observed phenomena. The present manuscript, for the first time, discusses the role of molecular structure in the optical emission of organic plasmas. Factors altering the electronic distribution within the organic molecule have been found to have a direct impact on its ensuing optical emissions. The electron structure of an organic molecule, resulting from the presence, nature, and position of its atoms, governs the breakage of the molecule and, as a result, determines the extent of atomization and fragmentation that has proved to directly impact the emissions of CN radicals and C2 dimers. Particular properties of the molecule respond more positively depending on the laser irradiation wavelength, thereby redirecting the ablation process through photochemical or photothermal decomposition pathways. It is of paramount significance for chemical identification purposes how, despite the large energy stored and dissipated by the plasma and the considerable number of transient species formed, the emissions observed never lose sight of the original molecule.

  5. The calculation of electron chemical potential and ion charge state and their influence on plasma conductivity in electrical explosion of metal wire

    International Nuclear Information System (INIS)

    Shi, Zongqian; Wang, Kun; Li, Yao; Shi, Yuanjie; Wu, Jian; Jia, Shenli

    2014-01-01

    The electron chemical potential and ion charge state (average ion charge and ion distribution) are important parameters in calculating plasma conductivity in electrical explosion of metal wire. In this paper, the calculating method of electron chemical potential and ion charge state is discussed at first. For the calculation of electron chemical potential, the ideal free electron gas model and Thomas-Fermi model are compared and analyzed in terms of the coupling constant of plasma. The Thomas-Fermi ionization model, which is used to calculate ion charge state, is compared with the method based on Saha equation. Furthermore, the influence of electron degenerated energy levels and ion excited states in Saha equation on the ion charge state is also analyzed. Then the influence of different calculating methods of electron chemical potential and ion charge state on plasma conductivity is discussed by applying them in the Lee-More conductivity model

  6. The Chemical Potential of Plasma Membrane Cholesterol: Implications for Cell Biology.

    Science.gov (United States)

    Ayuyan, Artem G; Cohen, Fredric S

    2018-02-27

    Cholesterol is abundant in plasma membranes and exhibits a variety of interactions throughout the membrane. Chemical potential accounts for thermodynamic consequences of molecular interactions, and quantifies the effective concentration (i.e., activity) of any substance participating in a process. We have developed, to our knowledge, the first method to measure cholesterol chemical potential in plasma membranes. This was accomplished by complexing methyl-β-cyclodextrin with cholesterol in an aqueous solution and equilibrating it with an organic solvent containing dissolved cholesterol. The chemical potential of cholesterol was thereby equalized in the two phases. Because cholesterol is dilute in the organic phase, here activity and concentration were equivalent. This equivalence allowed the amount of cholesterol bound to methyl-β-cyclodextrin to be converted to cholesterol chemical potential. Our method was used to determine the chemical potential of cholesterol in erythrocytes and in plasma membranes of nucleated cells in culture. For erythrocytes, the chemical potential did not vary when the concentration was below a critical value. Above this value, the chemical potential progressively increased with concentration. We used standard cancer lines to characterize cholesterol chemical potential in plasma membranes of nucleated cells. This chemical potential was significantly greater for highly metastatic breast cancer cells than for nonmetastatic breast cancer cells. Chemical potential depended on density of the cancer cells. A method to alter and fix the cholesterol chemical potential to any value (i.e., a cholesterol chemical potential clamp) was also developed. Cholesterol content did not change when cells were clamped for 24-48 h. It was found that the level of activation of the transcription factor STAT3 increased with increasing cholesterol chemical potential. The cholesterol chemical potential may regulate signaling pathways. Copyright © 2018. Published by

  7. Multiscale multiphysics nonempirical approach to calculation of light emission properties of chemically active nonequilibrium plasma: application to Ar-GaI3 system

    International Nuclear Information System (INIS)

    Adamson, S; Astapenko, V; Chernysheva, I; Chorkov, V; Deminsky, M; Demchenko, G; Demura, A; Demyanov, A; Dyatko, N; Eletzkii, A; Knizhnik, A; Kochetov, I; Napartovich, A; Rykova, E; Sukhanov, L; Umanskii, S; Vetchinkin, A; Zaitsevskii, A; Potapkin, B

    2007-01-01

    Present-day computational techniques provide a possibility of evaluating properties of macrosystems using ab initio quantum chemistry and theories of elementary processes. Physical and chemical phenomena on very different timescales have to be taken into account (excitation, emission, chemical reactions, diffusion) at different levels of refining. This refining covers a very wide region of parameters starting from the structure of species up to the macro chemical mechanism of their conversion. This multilevel approach is described in detail in the paper and includes interaction and data transfer between different levels of phenomena description. In the framework of the approach, unknown properties of molecules, ions and atoms (structure, potential energy curves, transition dipole moments) are calculated based on quantum-chemical methods. The calculation results are used to evaluate rate characteristics of physical and chemical processes. The developed kinetic state-to-state scheme is then used to calculate the macro properties of the system under investigation. As an example of the multilevel approach, the emission properties of the Ar-GaI 3 positive column discharge plasma were calculated using the Chemical Work Bench computational environment. The calculations yield the electron energy balance and emission efficiency as functions of plasma parameters

  8. Plasma parameters effects on the properties, aging and stability behaviors of allylamine plasma coated ultra-high molecular weight polyethylene (UHMWPE) films

    Energy Technology Data Exchange (ETDEWEB)

    Aziz, Gaelle, E-mail: gaelle.aziz@ugent.be; Thukkaram, Monica; De Geyter, Nathalie; Morent, Rino

    2017-07-01

    Highlights: • Medium to atmospheric pressure DBD is used to deposit amino rich films. • Process parameters affect the films’ surface chemical and physical properties. • High deposition rates can be reached by varying the power and/or monomer flow rate. • High amino selectivity (NH{sub 2}/N in %) is obtained at low powers and high monomer concentration. • Aging and stability behaviors of the deposited coatings can be controlled by carefully choosing the plasma parameters. - Abstract: In this work, a dielectric barrier discharge (DBD) operated at medium to atmospheric pressure has been used for the deposition of thin polyallylamine (PAA) films on ultra-high molecular weight polyethylene (UHMWPE) substrates. The effect of treatment time (1–5 min), discharge power (5.7–24.0 W), monomer concentration (1–2 g/h) and pressure (10–100 kPa) on the films properties, aging and stability behaviors have been investigated. The used characterization techniques are X-ray photoelectron spectroscopy, water contact angle and optical reflectance spectroscopy. In this paper, it is shown that plasma treatment time does not affect the coatings chemistry; whereas plasma power, monomer concentration and pressure control the coatings properties. It is also shown that the deposition rate of the deposited films changes with varying W/FM values. At low W/FM values, high deposition rates of up to 2 nm/s are observed. Plasma treatments were also characterized by their amino efficiency ([NH{sub 2}]/[C] in %) and amino selectivity ([NH{sub 2}]/[N] in %). Depending on the used parameters, these varied between 12.3% and 20% and between 71.2% and 91.1%, respectively. For the aging study, coatings that preserved most of their hydrophilicity were obtained at power ≤11.3 W, monomer concentration ≥1.5 g/h and pressure ≥50 kPa. For the stability study, coatings that showed the highest [N] (%) and lowest percentage of thickness decrease were obtained at ≤2 min, 24.0 W, 1 g/h and

  9. Relationships between organohalogen contaminants and blood plasma clinical-chemical parameters in chicks of three raptor species from Northern Norway

    DEFF Research Database (Denmark)

    Sonne, Christian; Bustnes, Jan Ove; Herzke, Dorte

    2010-01-01

    :creatinine were significantly positively correlated to various OHCs (all: praptor chicks of Northern Scandinavia may impact blood plasma biochemistry in a way that indicates impacts on liver, kidney, bone...

  10. RF plasma parameter determination by a Langmuir multipoint double probe array

    International Nuclear Information System (INIS)

    Rojas-Olmedo, I A; López-Callejas, R; De la Piedad-Beneitez, A; Valencia-Alvarado, R; Peña-Eguiluz, R; Mercado-Cabrera, A; Barocio, S R; Muñoz-Castro, A E; Rodríguez-Méndez, B G

    2012-01-01

    A multipoint double Langmuir (MDL) probe system, which is exempt from interference, has been designed and assembled to be applied to an RF plasma. The system provides the measurement of fundamental plasma parameters such as density, temperature, plasma potential, etc. on the basis of the Bohm Approximation Theory and the Orbital Movement Limit. Thus, one pair of the MDL system is selected so as to consider the right plasma parameters within the prevailing pressure-power intervals. Both the hardware and software of the system have been applied to the modification of material properties by means of the PIII process.

  11. Clinical Symptoms in Fibromyalgia Are Better Associated to Lipid Peroxidation Levels in Blood Mononuclear Cells Rather than in Plasma

    Science.gov (United States)

    Cano-García, Francisco J.; De Miguel, Manuel; Carrión, Angel M.; Navas, Plácido; Sánchez Alcázar, José A.

    2011-01-01

    Background We examined lipid peroxidation (LPO) in blood mononuclear cells (BMCs) and plasma, as a marker of oxidative damage, and its association to clinical symptoms in Fibromyalgia (FM) patients. Methods We conducted a case–control and correlational study comparing 65 patients and 45 healthy controls. Clinical parameters were evaluated using the Fibromyalgia Impact Questionnaire (FIQ), visual analogues scales (VAS), and the Beck Depression Inventory (BDI). Oxidative stress was determined by measuring LPO in BMCs and plasma. Results We found increased LPO levels in BMCs and plasma from FM patients as compared to normal control (P<0.001). A significant correlation between LPO in BMCs and clinical parameters was observed (r = 0.584, P<0.001 for VAS; r = 0.823, P<0.001 for FIQ total score; and r = 0.875, P<0.01 for depression in the BDI). We also found a positive correlation between LPO in plasma and clinical symptoms (r = 0.452, P<0.001 for VAS; r = 0.578, P<0.001 for FIQ total score; and r = 0.579, P<0.001 for depression in the BDI). Partial correlation analysis controlling for age and BMI, and sex, showed that both LPO in cells and plasma were independently associated to clinical symptoms. However, LPO in cells, but not LPO in plasma, was independently associated to clinical symptoms when controlling for depression (BDI scores). Discussion The results of this study suggest a role for oxidative stress in the pathophysiology of fibromyalgia and that LPO in BMCs rather than LPO in plasma is better associated to clinical symptoms in FM. PMID:22046409

  12. Clinical symptoms in fibromyalgia are better associated to lipid peroxidation levels in blood mononuclear cells rather than in plasma.

    Directory of Open Access Journals (Sweden)

    Mario D Cordero

    Full Text Available BACKGROUND: We examined lipid peroxidation (LPO in blood mononuclear cells (BMCs and plasma, as a marker of oxidative damage, and its association to clinical symptoms in Fibromyalgia (FM patients. METHODS: We conducted a case-control and correlational study comparing 65 patients and 45 healthy controls. Clinical parameters were evaluated using the Fibromyalgia Impact Questionnaire (FIQ, visual analogues scales (VAS, and the Beck Depression Inventory (BDI. Oxidative stress was determined by measuring LPO in BMCs and plasma. RESULTS: We found increased LPO levels in BMCs and plasma from FM patients as compared to normal control (P<0.001. A significant correlation between LPO in BMCs and clinical parameters was observed (r = 0.584, P<0.001 for VAS; r = 0.823, P<0.001 for FIQ total score; and r = 0.875, P<0.01 for depression in the BDI. We also found a positive correlation between LPO in plasma and clinical symptoms (r = 0.452, P<0.001 for VAS; r = 0.578, P<0.001 for FIQ total score; and r = 0.579, P<0.001 for depression in the BDI. Partial correlation analysis controlling for age and BMI, and sex, showed that both LPO in cells and plasma were independently associated to clinical symptoms. However, LPO in cells, but not LPO in plasma, was independently associated to clinical symptoms when controlling for depression (BDI scores. DISCUSSION: The results of this study suggest a role for oxidative stress in the pathophysiology of fibromyalgia and that LPO in BMCs rather than LPO in plasma is better associated to clinical symptoms in FM.

  13. Clinical symptoms in fibromyalgia are better associated to lipid peroxidation levels in blood mononuclear cells rather than in plasma.

    Science.gov (United States)

    Cordero, Mario D; Alcocer-Gómez, Elísabet; Cano-García, Francisco J; De Miguel, Manuel; Carrión, Angel M; Navas, Plácido; Sánchez Alcázar, José A

    2011-01-01

    We examined lipid peroxidation (LPO) in blood mononuclear cells (BMCs) and plasma, as a marker of oxidative damage, and its association to clinical symptoms in Fibromyalgia (FM) patients. We conducted a case-control and correlational study comparing 65 patients and 45 healthy controls. Clinical parameters were evaluated using the Fibromyalgia Impact Questionnaire (FIQ), visual analogues scales (VAS), and the Beck Depression Inventory (BDI). Oxidative stress was determined by measuring LPO in BMCs and plasma. We found increased LPO levels in BMCs and plasma from FM patients as compared to normal control (PBMI, and sex, showed that both LPO in cells and plasma were independently associated to clinical symptoms. However, LPO in cells, but not LPO in plasma, was independently associated to clinical symptoms when controlling for depression (BDI scores). The results of this study suggest a role for oxidative stress in the pathophysiology of fibromyalgia and that LPO in BMCs rather than LPO in plasma is better associated to clinical symptoms in FM.

  14. Reduced chemical warfare agent sorption in polyurethane-painted surfaces via plasma-enhanced chemical vapor deposition of perfluoroalkanes.

    Science.gov (United States)

    Gordon, Wesley O; Peterson, Gregory W; Durke, Erin M

    2015-04-01

    Perfluoralkalation via plasma chemical vapor deposition has been used to improve hydrophobicity of surfaces. We have investigated this technique to improve the resistance of commercial polyurethane coatings to chemicals, such as chemical warfare agents. The reported results indicate the surface treatment minimizes the spread of agent droplets and the sorption of agent into the coating. The improvement in resistance is likely due to reduction of the coating's surface free energy via fluorine incorporation, but may also have contributing effects from surface morphology changes. The data indicates that plasma-based surface modifications may have utility in improving chemical resistance of commercial coatings.

  15. Fundamental aspects of plasma chemical physics transport

    CERN Document Server

    Capitelli, Mario; Laricchiuta, Annarita

    2013-01-01

    Fundamental Aspects of Plasma Chemical Physics: Tranpsort develops basic and advanced concepts of plasma transport to the modern treatment of the Chapman-Enskog method for the solution of the Boltzmann transport equation. The book invites the reader to consider actual problems of the transport of thermal plasmas with particular attention to the derivation of diffusion- and viscosity-type transport cross sections, stressing the role of resonant charge-exchange processes in affecting the diffusion-type collision calculation of viscosity-type collision integrals. A wide range of topics is then discussed including (1) the effect of non-equilibrium vibrational distributions on the transport of vibrational energy, (2) the role of electronically excited states in the transport properties of thermal plasmas, (3) the dependence of transport properties on the multitude of Saha equations for multi-temperature plasmas, and (4) the effect of the magnetic field on transport properties. Throughout the book, worked examples ...

  16. On the distribution of plasma parameters in RF glow discharge

    International Nuclear Information System (INIS)

    Ning Cheng; Liu Zuli; Liu Donghui; Han Caiyuan.

    1993-01-01

    A self-consistent numerical model based on the two-fluid equations for describing the transport of charged particles in the RF glow discharge is presented. For a plasma generator filled with low-pressure air and parallel-plate electrodes, the model is numerical solved. The space-time distribution of parameters and the spatial distribution of some time-averaged parameters in plasma, which show the physical picture of the RF glow discharge, are obtained

  17. Influence of Chemical Precleaning on the Plasma Treatment Efficiency of Aluminum by RF Plasma Pencil

    Czech Academy of Sciences Publication Activity Database

    Prysiazhnyi, V.; Slavíček, P.; Mikmeková, Eliška; Klíma, M.

    2016-01-01

    Roč. 18, č. 4 (2016), s. 430-437 ISSN 1009-0630 Institutional support: RVO:68081731 Keywords : atmospheric pressure plasma * plasma jet * aluminium * surface treatment * surface processing * chemical precleaning Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.830, year: 2016

  18. A proposed method for fast determination of plasma parameters

    International Nuclear Information System (INIS)

    Braams, B.J.; Lackner, K.

    1984-09-01

    The method of function parametrization, developed and applied by H. Wind for fast data evaluation in high energy physics, is presented in the context of controlled fusion research. This method relies on statistical analysis of a data base of simulated experiments in order to obtain a functional representation for the intrinsic physical parameters of a system in terms of the values of the measurements. Some variations on Wind's original procedure are suggested. A specific application for tokamak experiments would be the determination of certain global parameters of the plasma, characterizing the current profile, shape of the cross-section, plasma pressure, and the internal inductance. The relevant measurements for this application include values of the poloidal field and flux external to the plasma, and a diamagnetic measurement. These may be combined with other diagnostics, such as electron-cyclotron emission and laser interferometry, in order to obtain also density and temperature profiles. There appears to be a capability for on-line determination of basic physical parameters, in a millisecond timescale on a minicomputer instead of in seconds on a large mainframe. (orig.)

  19. Composition and partition functions of partially ionized hydrogen plasma in Non-Local Thermal Equilibrium (Non-LThE) and Non-Local Chemical Equilibrium (Non-LChE)

    International Nuclear Information System (INIS)

    Chen Kuan; Eddy, T.L.

    1993-01-01

    A GTME (Generalized MultiThermodynamic Equilibrium) plasma model is developed for plasmas in both Non-LThE (Non-Local Thermal Equilibrium) and Non-LChE (Non-Local Chemical Equilibrium). The model uses multitemperatures for thermal nonequilibrium and non-zero chemical affinities as a measure of the deviation from chemical equilibrium. The plasma is treated as an ideal gas with the Debye-Hueckel approximation employed for pressure correction. The proration method is used when the cutoff energy level is between two discrete levels. The composition and internal partition functions of a hydrogen plasma are presented for electron temperatures ranging from 5000 to 35000 K and pressures from 0.1 to 1000 kPa. Number densities of 7 different species of hydrogen plasma and internal partition functions of different energy modes (rotational, vibrational, and electronic excitation) are computed for three affinity values. The results differ from other plasma properties in that they 1) are not based on equilibrium properties; and 2) are expressed as a function of different energy distribution parameters (temperatures) within each energy mode of each species as appropriate. The computed number densities and partition functions are applicable to calculating the thermodynamic, transport, and radiation properties of a hydrogen plasma not in thermal and chemical equilibria. The nonequilibrium plasma model and plasma compositions presented in this paper are very useful to the diagnosis of high-speed and/or low-pressure plasma flows in which the assumptions of local thermal and chemical equilibrium are invalid. (orig.)

  20. Ion source plasma parameters measurement based on Langmuir probe with commercial frequency sweep

    International Nuclear Information System (INIS)

    Xie, Y.H.; Hu, C.D.; Liu, S.; Shong, S.H.; Jiang, C.C.; Liu, Z.M.

    2010-01-01

    Langmuir probe is one of the main diagnostic tools to measure the plasma parameters in the ion source. In this article, the commercial frequency power, which is sine wave of 50 Hz, was supplied on the Langmuir probe to measure the plasma parameters. The best feature of this probe sweep voltage is that it does not need extra design. The probe I-V characteristic curve can be got in less than 5 ms and the plasma parameters, the electron temperature and the electron density, varying with the time can be got in one plasma discharge of 400 ms.

  1. Study on spatial distribution of plasma parameters in a magnetized inductively coupled plasma

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Hee-Woon; Lee, Woohyun; Kim, Ji-Won; Whang, Ki-Woong, E-mail: kwhang@snu.ac.kr [Plasma Laboratory, Inter-University Semiconductor Research Center, Department of Electrical and Computer Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Kim, Hyuk [Samsung Electronics Co., Banwol-dong, Hwaseong 445-701 (Korea, Republic of); Park, Wanjae [Tokyo Electron Miyagi Ltd., Taiwa-cho, Kurokawa-gun, Miyagi 981-3629 (Japan)

    2015-07-15

    Spatial distributions of various plasma parameters such as plasma density, electron temperature, and radical density in an inductively coupled plasma (ICP) and a magnetized inductively coupled plasma (M-ICP) were investigated and compared. Electron temperature in between the rf window and the substrate holder of M-ICP was higher than that of ICP, whereas the one just above the substrate holder of M-ICP was similar to that of ICP when a weak (<8 G) magnetic field was employed. As a result, radical densities in M-ICP were higher than those in ICP and the etch rate of oxide in M-ICP was faster than that in ICP without severe electron charging in 90 nm high aspect ratio contact hole etch.

  2. North-South asymmetry of interplanetary plasma and solar parameters

    International Nuclear Information System (INIS)

    El-Borie, M. A.

    2001-01-01

    Data of interplanetary plasma (field magnitude, solar wind speed, ion plasma density and temperature) and solar parameters (sunspot number, solar radio flux, and geomagnetic index) over the period 1965-1991, have been used to examine the asymmetry between the solar field north and south of the heliospheric current sheet (HCS). The dependence of N-S asymmetry of field magnitude (B) upon the interplanetary solar polarities is statistically insignificant. There is no clear indication for the presence of N-S asymmetry in the grand-average field magnitude over the solar cycles. During the period 1981-89 (qA<0; negative solar polarity state), the solar plasma was more dense and cooler south of the HCS than north of it. The solar flux component of toward field vector is larger in magnitude than those of away field vector during the qA<0 epoch, and no asymmetry observed in the qA<0 epoch. Furthermore, the sign of the N-S asymmetry in the solar activity depends positively upon the solar polarity state. In addition, it was studied the N-S asymmetry of solar parameters near the HCS, throughout the periods of northern and southern hemispheres were more active than the other. Some asymmetries (with respect to the HCS) in plasma parameters existed during the periods of southern hemisphere predominance

  3. Effects of Hypertonic Saline Solution on Clinical Parameters, Serum Electrolytes and Plasma Volume in the Treatment of Haemorrhagic Septicaemia in Buffaloes

    Directory of Open Access Journals (Sweden)

    M. Arif Zafar*, G. Muhammad, Zafar Iqbal1 and M. Riaz2

    2010-04-01

    Full Text Available This study was conducted to determine the efficacy of hypertonic saline solution (HSS along with antibiotic (ceftiofur HCl and non-steroidal anti-inflammatory drug (ketoprofen in the treatment of haemorrhagic septicaemia in buffaloes. For this purpose, 50 buffaloes suffering from haemorrhagic septicaemia were randomly divided in two equal groups A and B. Group A served as control and was treated with ceftiofur HCl (IM and ketoprofen (IV @ 6 and 2 mg/Kg BW, respectively, for five days. Buffaloes of group B were administered with rapid intravenous infusion of hypertonic saline solution (7.5% NaCl @ 4 ml/Kg BW once in combination with ceftiofur HCl and ketoprofen. Animals were monitored for 24 hours after initiation of treatment. Clinical parameters, serum electrolytes, plasma volume and survival index were recorded at different intervals after treatment. Survival rate (80% in group B was significantly higher (P<0.05 than 48% in group A. The heart rate and respiration rate recovered more effectively in the buffaloes administered with treatment protocol B. Plasma volume was 98% which was almost normal within 24 hours after the infusion of hypertonic saline solution to the animals of group B. It was concluded from the study that hypertonic saline solution as an adjunct to antibiotic and a non-steroidal anti-inflammatory drug more efficiently improved respiration and heart rates and effectively restored plasma volume in resuscitating the buffaloes from haemorrhagic septicaemia than the conventional treatment.

  4. Revisiting linear plasma waves for finite value of the plasma parameter

    Science.gov (United States)

    Grismayer, Thomas; Fahlen, Jay; Decyk, Viktor; Mori, Warren

    2010-11-01

    We investigate through theory and PIC simulations the Landau-damping of plasma waves with finite plasma parameter. We concentrate on the linear regime, γφB, where the waves are typically small and below the thermal noise. We simulate these condition using 1,2,3D electrostatic PIC codes (BEPS), noting that modern computers now allow us to simulate cases where (nλD^3 = [1e2;1e6]). We study these waves by using a subtraction technique in which two simulations are carried out. In the first, a small wave is initialized or driven, in the second no wave is excited. The results are subtracted to provide a clean signal that can be studied. As nλD^3 is decreased, the number of resonant electrons can be small for linear waves. We show how the damping changes as a result of having few resonant particles. We also find that for small nλD^3 fluctuations can cause the electrons to undergo collisions that eventually destroy the initial wave. A quantity of interest is the the life time of a particular mode which depends on the plasma parameter and the wave number. The life time is estimated and then compared with the numerical results. A surprising result is that even for large values of nλD^3 some non-Vlasov discreteness effects appear to be important.

  5. Chemical analysis of plasma-assisted antimicrobial treatment on cotton

    International Nuclear Information System (INIS)

    Kan, C W; Lam, Y L; Yuen, C W M; Luximon, A; Lau, K W; Chen, K S

    2013-01-01

    This paper explores the use of plasma treatment as a pretreatment process to assist the application of antimicrobial process on cotton fabric with good functional effect. In this paper, antimicrobial finishing agent, Microfresh Liquid Formulation 9200-200 (MF), and a binder (polyurethane dispersion, Microban Liquid Formulation R10800-0, MB) will be used for treating the cotton fabric for improving the antimicrobial property and pre-treatment of cotton fabric by plasma under atmospheric pressure will be employed to improve loading of chemical agents. The chemical analysis of the treated cotton fabric will be conducted by Fourier transform Infrared Spectroscopy.

  6. Plasma Arc Cutting Dimensional Accuracy Optimization employing the Parameter Design approach

    Directory of Open Access Journals (Sweden)

    Kechagias John

    2017-01-01

    Full Text Available Plasma Arc Cutting (PAC is a thermal manufacturing process used for metal plates cutting. This work experimentally investigates the influence of process parameters onto the dimensional accuracy performance of the plasma arc cutting process. The cutting parameters studied were cutting speed (mm/min, torch standoff distance (mm, and arc voltage (volts. Linear dimensions of a rectangular workpiece were measured after PAC cutting following the full factorial design experimental approach. For each one of the three process parameters, three parameter levels were used. Analysis of means (ANOM and analysis of variances (ANOVA were performed in order for the effect of each parameter on the leaner dimensional accuracy to be assessed.

  7. Time-resolved resonance fluorescence spectroscopy for study of chemical reactions in laser-induced plasmas.

    Science.gov (United States)

    Liu, Lei; Deng, Leimin; Fan, Lisha; Huang, Xi; Lu, Yao; Shen, Xiaokang; Jiang, Lan; Silvain, Jean-François; Lu, Yongfeng

    2017-10-30

    Identification of chemical intermediates and study of chemical reaction pathways and mechanisms in laser-induced plasmas are important for laser-ablated applications. Laser-induced breakdown spectroscopy (LIBS), as a promising spectroscopic technique, is efficient for elemental analyses but can only provide limited information about chemical products in laser-induced plasmas. In this work, time-resolved resonance fluorescence spectroscopy was studied as a promising tool for the study of chemical reactions in laser-induced plasmas. Resonance fluorescence excitation of diatomic aluminum monoxide (AlO) and triatomic dialuminum monoxide (Al 2 O) was used to identify these chemical intermediates. Time-resolved fluorescence spectra of AlO and Al 2 O were used to observe the temporal evolution in laser-induced Al plasmas and to study their formation in the Al-O 2 chemistry in air.

  8. Applying chemical engineering concepts to non-thermal plasma reactors

    Science.gov (United States)

    Pedro AFFONSO, NOBREGA; Alain, GAUNAND; Vandad, ROHANI; François, CAUNEAU; Laurent, FULCHERI

    2018-06-01

    Process scale-up remains a considerable challenge for environmental applications of non-thermal plasmas. Undersanding the impact of reactor hydrodynamics in the performance of the process is a key step to overcome this challenge. In this work, we apply chemical engineering concepts to analyse the impact that different non-thermal plasma reactor configurations and regimes, such as laminar or plug flow, may have on the reactor performance. We do this in the particular context of the removal of pollutants by non-thermal plasmas, for which a simplified model is available. We generalise this model to different reactor configurations and, under certain hypotheses, we show that a reactor in the laminar regime may have a behaviour significantly different from one in the plug flow regime, often assumed in the non-thermal plasma literature. On the other hand, we show that a packed-bed reactor behaves very similarly to one in the plug flow regime. Beyond those results, the reader will find in this work a quick introduction to chemical reaction engineering concepts.

  9. Dependence of the source performance on plasma parameters at the BATMAN test facility

    Science.gov (United States)

    Wimmer, C.; Fantz, U.

    2015-04-01

    The investigation of the dependence of the source performance (high jH-, low je) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H-, its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H- density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa).

  10. Dependence of the source performance on plasma parameters at the BATMAN test facility

    International Nuclear Information System (INIS)

    Wimmer, C.; Fantz, U.

    2015-01-01

    The investigation of the dependence of the source performance (high j H − , low j e ) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H − , its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H − density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa)

  11. Plasma Arc Cutting Dimensional Accuracy Optimization employing the Parameter Design approach

    OpenAIRE

    Kechagias John; Petousis Markos; Vidakis Nectarios; Mastorakis Nikos

    2017-01-01

    Plasma Arc Cutting (PAC) is a thermal manufacturing process used for metal plates cutting. This work experimentally investigates the influence of process parameters onto the dimensional accuracy performance of the plasma arc cutting process. The cutting parameters studied were cutting speed (mm/min), torch standoff distance (mm), and arc voltage (volts). Linear dimensions of a rectangular workpiece were measured after PAC cutting following the full factorial design experimental approach. For ...

  12. Study of plasma-chemical NO-containing gas flow for treatment of wounds and inflammatory processes.

    Science.gov (United States)

    Pekshev, Alexander V; Shekhter, Anatoly B; Vagapov, Andrey B; Sharapov, Nikolay A; Vanin, Anatoly F

    2018-02-28

    This work is aimed at exhaustive and detailed study of chemical, physical and physico-chemical characteristics of NO-containing gas flow (NO-CGF) generated by a plasma-chemical generator of Plason device, which has been used in medical practice for more than 15 years for effectively healing wound and inflammatory conditions with exogenous nitric oxide (NO-therapy). Data was obtained on spatial structure of the gas flow, and values of its local parameters in axial and radial directions, such as nitric oxide content, velocity, temperature and mass flow density of nitric oxide, providing altogether the effectiveness of treatment by the exogenous NO-therapy method, were determined experimentally and by computations. It was demonstrated that plasma-chemical synthesis of NO from atmospheric air in a low direct current (DC) arc provides a high mass flow of nitric oxide at the level of 1.6-1.8 mg/s, while in the area of impact of NO-CGF on the biological tissue, on its axis, NO content is 400-600 ppm, flow velocity about 5 m/s, nitric oxide mass flow density 0.25-0.40 mg/(s·cm 2 ), temperature 40-60 °C. Tendencies were determined for designing new devices for further experimental biological and medical research in the field of NO-therapy: lowering the temperature of NO-CGF to ambient temperature will enable variation, in experiments, of the affecting flow parameters in a wide range up to their maximum values: NO content up to 2000 ppm, velocity up to 20 m/s, nitric oxide mass flow density up to 2.5 mg/(s·cm 2 ). Copyright © 2017. Published by Elsevier Inc.

  13. Effect of dietary protein levels on growth performance, mortality rate and clinical blood parameters in mink (Mustela vison)

    DEFF Research Database (Denmark)

    Damgaard, B.M.; Clausen, T.N.; Dietz, Hans Henrik

    1998-01-01

    Effects of dietary protein levels ranging from 35% to 15% of metabolizable energy (ME) and dietary fat levels ranging in a reciprocal fashion from 47% to 67% of ME, and a constant dietary carbohydrate level of 18% of ME were investigated in male mink kits in the growing-furring period. Growth...... performance, mortality rate, hepatic fatty infiltration, weights of body and liver, relative weight of liver, haematocrit values, plasma activities of alanine-aminotransferase (ALAT), aspartate-aminotransferase (ASAT) and creatine-kinase (CK), and plasma concentrations of chemical parameters were studied...

  14. Fundamental limits on gas-phase chemical reduction of NOx in a plasma

    Energy Technology Data Exchange (ETDEWEB)

    Penetrante, B.M.; Hsiao, M.C.; Merritt, B.T.; Vogtlin, G.E. [Lawrence Livermore National Lab., CA (United States)

    1997-12-31

    In the plasma, the electrons do not react directly with the NOx molecules. The electrons collide mainly with the background gas molecules like N{sub 2}, O{sub 2} and H{sub 2}O. Electron impact on these molecules result partly in dissociation reactions that produce reactive species like N, O and OH. The NOx in the engine exhaust gas initially consist mostly of NO. The ground state nitrogen atom, N, is the only species that could lead to the chemical reduction of NO to N{sub 2}. The O radical oxidizes NO to NO{sub 2} leaving the same amount of NOx. The OH radical converts NO{sub 2} to nitric acid. Acid products in the plasma can easily get adsorbed on surfaces in the plasma reactor and in the pipes. When undetected, the absence of these oxidation products can often be mistaken for chemical reduction of NOx. In this paper the authors will examine the gas-phase chemical reduction of NOx. They will show that under the best conditions, the plasma can chemically reduce 1.6 grams of NOx per brake-horsepower-hour [g(NOx)/bhp-hr] when 5% of the engine output energy is delivered to the plasma.

  15. Improvement of Plating Characteristics Between Nickel and PEEK by Plasma Treatment and Chemical Etching

    International Nuclear Information System (INIS)

    Lee, Hye W.; Lee, Jong K.; Park, Ki Y.

    2009-01-01

    Surface of PEEK(poly-ether-ether-ketone) was modified by chemical etching, plasma treatment and mechanical grinding to improve the plating adhesion. The plating characteristics of these samples were studied by the contact angle, plating thickness, gloss and adhesion. Chemical etching and plasma treatment increased wettability, adhesion and gloss. The contact angle of as-received PEEK was 61 .deg. . The contact angles of chemical etched, plasma treated or both were improved to the range of 15∼33 .deg. . In the case of electroless plating, the thickest layer without blister was 1.6 μm. The adhesion strengths by chemical etching, plasma treatment or both chemical etching and plasma treatment were 75 kgf/cm 2 , 102 kgf/cm 2 , 113 kgf/cm 2 , respectively, comparing to the 24 kgf/cm 2 of as-received. In the case of mechanically ground PEEKs, the adhesion strengths were higher than those unground, with the sacrifice of surface gloss. The gloss of untreated PEEK were greater than mechanically ground PEEKs. Plating thickness increased linearly with the plating times

  16. Plasma jet source parameter optimisation and experiments on injection into Globus-M spherical tokamak

    International Nuclear Information System (INIS)

    Gusev, V.K.; Petrov, Yu.V.; Sakharov, N.V.; Semenov, A.A.; Voronin, A.V.

    2005-01-01

    Results of theoretical and experimental research on the plasma sources and injection of plasma and gas jet produced by the modified source into tokamak Globus-M are presented. An experimental test stand was developed for investigation of intense plasma jet generation. Optimisation of pulsed coaxial accelerator parameters by means of analytical calculations is performed with the aim of achieving the highest flow velocity at limited coaxial electrode length and discharge current. The optimal parameters of power supply to generate a plasma jet with minimal impurity contamination and maximum flow velocity were determined. A comparison of experimental and calculation results is made. Plasma jet parameters are measured, such as: impurity species content, pressure distribution across the jet, flow velocity, plasma density, etc. Experiments on the interaction of a higher kinetic energy plasma jet with the magnetic field and plasma of the Globus-M tokamak were performed. Experimental results on plasma and gas jet injection into different Globus-M discharge phases are presented and discussed. Results are presented on the investigation of plasma jet injection as the source for discharge breakdown, plasma current startup and initial density rise. (author)

  17. Plasma-Lyte 148: A clinical review

    Science.gov (United States)

    Weinberg, Laurence; Collins, Neil; Van Mourik, Kiara; Tan, Chong; Bellomo, Rinaldo

    2016-01-01

    AIM To outline the physiochemical properties and specific clinical uses of Plasma-Lyte 148 as choice of solution for fluid intervention in critical illness, surgery and perioperative medicine. METHODS We performed an electronic literature search from Medline and PubMed (via Ovid), anesthesia and pharmacology textbooks, and online sources including studies that compared Plasma-Lyte 148 to other crystalloid solutions. The following keywords were used: “surgery”, “anaesthesia”, “anesthesia”, “anesthesiology”, “anaesthesiology”, “fluids”, “fluid therapy”, “crystalloid”, “saline”, “plasma-Lyte”, “plasmalyte”, “hartmann’s”, “ringers” “acetate”, “gluconate”, “malate”, “lactate”. All relevant articles were accessed in full. We summarized the data and reported the data in tables and text. RESULTS We retrieved 104 articles relevant to the choice of Plasma-Lyte 148 for fluid intervention in critical illness, surgery and perioperative medicine. We analyzed the data and reported the results in tables and text. CONCLUSION Plasma-Lyte 148 is an isotonic, buffered intravenous crystalloid solution with a physiochemical composition that closely reflects human plasma. Emerging data supports the use of buffered crystalloid solutions in preference to saline in improving physicochemical outcomes. Further large randomized controlled trials assessing the comparative effectiveness of Plasma-Lyte 148 and other crystalloid solutions in measuring clinically important outcomes such as morbidity and mortality are needed. PMID:27896148

  18. Improvement in the performance of external quality assessment in Korean HIV clinical laboratories using unrecalcified human plasma.

    Science.gov (United States)

    Wang, Jin-Sook; Kee, Mee-Kyung; Choi, Byeong-Sun; Kim, Chan-Wha; Kim, Hyon-Suk; Kim, Sung Soon

    2012-01-01

    The external quality assessment schemes (EQAS) organizer provides a suitable program to monitor and improve the quality of human immunodeficiency virus (HIV) testing laboratories with EQAS panels prepared under various conditions. The aim of the current study was to investigate the effects of human plasma samples on the EQAS results of HIV obtained from hospital-based clinical laboratories. From 2007 to 2009, HIV EQAS panels consisted of four to six samples that consisted of undiluted positive and negative samples and were provided to laboratories twice per year. Up until the first half EQAS in 2008, EQAS panel materials were obtained by converting acid citrate dextrose treated plasma to serum via chemical treatment with CaCl2. Beginning with the second EQAS in 2008, all materials were prepared without the defibrination process. Approximately 300 HIV clinical laboratories participated in this program. The overall performance of clinical laboratories was shown to be improved when using unrecalcified plasma panels compared with recalcified panels. Significant differences were observed in EIA analyses of plasma for both positive (plaboratories.

  19. Reference values of amino acids and of common clinical chemistry in plasma of healthy infants aged 1 and 4 months.

    Science.gov (United States)

    Haschke-Becher, Elisabeth; Kainz, Alexander; Bachmann, Claude

    2016-01-01

    To compare plasma levels of amino acids and clinical chemistry parameters in healthy infants at 1 and 4 months of age and to establish corresponding reference limits. Data of three multicenter studies assessing the safety of new infant formulas were used. During these studies infants of both age-groups were either breast-fed or received formulas of low or high protein content. All samples were analyzed centrally in the same accredited laboratory. Plasma was collected from 521 infants in total, 157 boys and 135 girls aged 1 month and 121 boys and 108 girls aged 4 months. At the age of 1 month, 62 infants had received exclusively breast milk, 198 exclusively formula, and 27 both; in the 4-months age group corresponding numbers were 49, 158 and 18, respectively; for 9 infants, diet was unknown. Concentrations of most amino acids and clinical chemistry parameters differed significantly between both ages. Regardless of age, most plasma amino acid levels were comparable or lower in breast-fed than in formula-fed infants whereas at 1 month of age most clinical chemistry parameters were higher. While in breast-fed infants the plasma urea concentration decreased over 4 months of age, it increased in formula-fed infants. There were significant differences between infants fed a low and high protein formula. At both ages, high protein formulas resulted in significantly higher threonine, 2-aminobutyrate, and urea concentrations. For clinical use, age- and diet specific reference limits in infants are warranted.

  20. Investigation of shock compressed plasma parameters by interaction with magnetic field

    International Nuclear Information System (INIS)

    Dudin, S. V.; Fortov, V. E.; Gryaznov, V. K.; Mintsev, V. B.; Shilkin, N. S.; Ushnurtsev, A. E.

    1998-01-01

    The Hall effect parameters in shock compressed air, helium and xenon have been estimated and results of experiments with air and helium plasma are presented. Explosively driven shock tubes were used for the generation of strong shock waves. To obtain magnetic field a solenoid was winded over the shock tube. Calculations of dense shock compressed plasma parameters were carried out to plan the experiments. In the experiments with the magnetic field of ∼5 T it was found, that air plasma slug was significantly heated by the whirlwind electrical field. The reflected shock waves technique was used in the experiments with helium. Results on measurements of electrical conductivity and electron concentration of helium are presented

  1. Gravimetrical and chemical characterization of SiOx structures deposited on fine powders by short plasma exposure in a plasma down stream reactor

    International Nuclear Information System (INIS)

    Spillmann, Adrian; Sonnenfeld, Axel; Rohr, Philipp Rudolf von

    2008-01-01

    The surface of lactose particles was modified by a plasma-enhanced chemical vapor deposition process to improve the flow behavior of the powder. For this, the particulates were treated in a plasma down stream reactor which provides a short (50 ms) and homogeneous exposure to the capacitively coupled RF discharge. The organosilicon monomer hexamethyldisiloxane (HMDSO) was used as a precursor for the formation of SiO x which is deposited on the substrate particle surface. For varying process gas mixtures (O 2 /Ar/HMDSO) and RF power applied, the amount of the deposited material was determined gravimetrically after dissolution of the lactose substrate particles and the chemical composition of the accumulated deposition material was investigated by means of attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. The concentration of the deposited SiO x relating to the substrate material was found to be in the range of 0.1 wt.%. Based on the ATR-FTIR analysis, the inorganic, i.e. oxidic SiO x fraction of the obtained deposits was shown to be controllable by varying the process parameters, whilst a relatively large amount of organic structures must be considered.

  2. Change in plasma lactate concentration during arctigenin administration in a phase I clinical trial in patients with gemcitabine-refractory pancreatic cancer.

    Science.gov (United States)

    Fujioka, Rumi; Mochizuki, Nobuo; Ikeda, Masafumi; Sato, Akihiro; Nomura, Shogo; Owada, Satoshi; Yomoda, Satoshi; Tsuchihara, Katsuya; Kishino, Satoshi; Esumi, Hiroyasu

    2018-01-01

    Arctigenin is evaluated for antitumor efficacy in patients with pancreatic cancer. It has an inhibitory activity on mitochondrial complex I.Therefore, plasma lactate level of patients after arctigenin administration was evaluated for biomarker of clinical response and/or adverse effect. Plasma lactate level in 15 patients enrolled in a Phase I clinical trial of GBS-01 rich in arctigenin was analyzed by colorimetric assay. Statistical analyses for association of plasma lactate and clinical responses, pharmacokinetics of arctigenin, and background factors of each patient by multivariate and univariate analyses.In about half of the patients, transient increase of lactate was observed. Correlation between plasma lactate level and pharmacokinetic parameters of arctigenin and its glucuronide conjugate, and clinical outcome was not detected. Regarding to the determinant of lactate level, only slight association with liver function test was detected. Plasma lactate level is primary determined by reutilization rather than production for antitumor effect and dose not serve as a biomarker. Arctigenin, inhibition of mitochondrial complex I, plasma lactate concentration, phase I clinical trial of GBS-01, Cori cycle.

  3. Change in plasma lactate concentration during arctigenin administration in a phase I clinical trial in patients with gemcitabine-refractory pancreatic cancer.

    Directory of Open Access Journals (Sweden)

    Rumi Fujioka

    Full Text Available Arctigenin is evaluated for antitumor efficacy in patients with pancreatic cancer. It has an inhibitory activity on mitochondrial complex I.Therefore, plasma lactate level of patients after arctigenin administration was evaluated for biomarker of clinical response and/or adverse effect. Plasma lactate level in 15 patients enrolled in a Phase I clinical trial of GBS-01 rich in arctigenin was analyzed by colorimetric assay. Statistical analyses for association of plasma lactate and clinical responses, pharmacokinetics of arctigenin, and background factors of each patient by multivariate and univariate analyses.In about half of the patients, transient increase of lactate was observed. Correlation between plasma lactate level and pharmacokinetic parameters of arctigenin and its glucuronide conjugate, and clinical outcome was not detected. Regarding to the determinant of lactate level, only slight association with liver function test was detected. Plasma lactate level is primary determined by reutilization rather than production for antitumor effect and dose not serve as a biomarker. Arctigenin, inhibition of mitochondrial complex I, plasma lactate concentration, phase I clinical trial of GBS-01, Cori cycle.

  4. Correlation between the plasma characteristics and the surface chemistry of plasma-treated polymers through partial least-squares analysis.

    Science.gov (United States)

    Mavadat, Maryam; Ghasemzadeh-Barvarz, Massoud; Turgeon, Stéphane; Duchesne, Carl; Laroche, Gaétan

    2013-12-23

    We investigated the effect of various plasma parameters (relative density of atomic N and H, plasma temperature, and vibrational temperature) and process conditions (pressure and H2/(N2 + H2) ratio) on the chemical composition of modified poly(tetrafluoroethylene) (PTFE). The plasma parameters were measured by means of near-infrared (NIR) and UV-visible emission spectroscopy with and without actinometry. The process conditions of the N2-H2 microwave discharges were set at various pressures ranging from 100 to 2000 mTorr and H2/(N2+H2) gas mixture ratios between 0 and 0.4. The surface chemical composition of the modified polymers was determined by X-ray photoelectron spectroscopy (XPS). A mathematical model was constructed using the partial least-squares regression algorithm to correlate the plasma information (process condition and plasma parameters as determined by emission spectroscopy) with the modified surface characteristics. To construct the model, a set of data input variables containing process conditions and plasma parameters were generated, as well as a response matrix containing the surface composition of the polymer. This model was used to predict the composition of PTFE surfaces subjected to N2-H2 plasma treatment. Contrary to what is generally accepted in the literature, the present data demonstrate that hydrogen is not directly involved in the defluorination of the surface but rather produces atomic nitrogen and/or NH radicals that are shown to be at the origin of fluorine atom removal from the polymer surface. The results show that process conditions alone do not suffice in predicting the surface chemical composition and that the plasma characteristics, which cannot be easily correlated with these conditions, should be considered. Process optimization and control would benefit from plasma diagnostics, particularly infrared emission spectroscopy.

  5. The Synergistic Effect between Electrical and Chemical Factors in Plasma Gene/Molecule-Transfection

    Science.gov (United States)

    Jinno, Masafumi

    2016-09-01

    This study has been done to know what kind of factors in plasma and processes on cells promote plasma gene/molecule transfection. We have discovered a new plasma source using a microcapillary electrode which enables high transfection efficiency and high cell survivability simultaneously. However, the mechanism of the transfection by plasma was not clear. To clarify the transfection mechanisms by micro plasma, we focused on the effects of electrical (current, charge, field, etc.) and chemical (radicals, RONS, etc.) factors generated by the micro plasma and evaluated the contribution weight of three groups of the effects and processes, i.e. electrical, chemical and biochemical ones. At first, the necessity of the electrical factors was estimated by the laser produced plasma (LPP). Mouse L-929 fibroblast cell was cultured on a 96-well plate or 12-well micro slide chamber. Plasmids pCX-EGFP in Tris-EDTA buffer was dropped on the cells and they were exposed to the capillary discharge plasma (CDP) or the LPP. In the case of the CDP, the plasma was generated between the tip of the capillary electrode and the cells so that both electrical and chemical factors were supplied to the cells. In this setup, about 20% of average transfection efficiency was obtained. In the case of the LPP, the plasma was generated apart from the cells so that electrical factors were not supplied to the cells. In this setup, no transfection was observed. These results show that the electrical factors are necessary for the plasma gene transfection. Next, the necessity of the chemical factors was estimated the effect of catalase to remove H2O2 in CDP. The transfection efficiency decreased to 0.4 by scavenging H2O2 with catalase. However, only the solution of H2O2 caused no gene transfection in cells. These results shows that H2O2 is important species to cause gene/molecule transfection but still needs a synergistic effect with electrical or other chemical factors. This work was partly supported by

  6. The Influence of the Axial Magnetic Field Upon-the Coaxial Plasma Gun Parameters

    International Nuclear Information System (INIS)

    El-Aragi, G.M.; EL-Demrdash, A.

    2001-01-01

    This study concerns with the influence of an applied axial magnetic field upon the electrical parameters of a coaxial plasma gun device. The experimental results are investigated with 0.5 KJ plasma gun device operated with argon gas at a pressure of 3.5 Torr. An axial time independent magnetic field with intensity of 550 G is introduced along the plasma current sheath axial region, within the annular space between the two coaxial electrodes. From the measurements of the discharge current I(t) and the voltage V(t), the electrical discharge parameters of the plasma gun device and the plasma current sheath implosion velocity are estimated, in normal mode of plasma gun operation and in the mode of presence external axial magnetic field. A comparison between these two modes is studied

  7. Real-Time Clinical Decision Support Decreases Inappropriate Plasma Transfusion.

    Science.gov (United States)

    Shah, Neil; Baker, Steven A; Spain, David; Shieh, Lisa; Shepard, John; Hadhazy, Eric; Maggio, Paul; Goodnough, Lawrence T

    2017-08-01

    To curtail inappropriate plasma transfusions, we instituted clinical decision support as an alert upon order entry if the patient's recent international normalized ratio (INR) was 1.7 or less. The alert was suppressed for massive transfusion and within operative or apheresis settings. The plasma order was automatically removed upon alert acceptance while clinical exception reasons allowed for continued transfusion. Alert impact was studied comparing a 7-month control period with a 4-month intervention period. Monthly plasma utilization decreased 17.4%, from a mean ± SD of 3.40 ± 0.48 to 2.82 ± 0.6 plasma units per hundred patient days (95% confidence interval [CI] of difference, -0.1 to 1.3). Plasma transfused below an INR of 1.7 or less decreased from 47.6% to 41.6% (P = .0002; odds ratio, 0.78; 95% CI, 0.69-0.89). The alert recommendation was accepted 33% of the time while clinical exceptions were chosen in the remaining cases (active bleeding, 31%; other clinical indication, 33%; and apheresis, 2%). Alert acceptance rate varied significantly among different provider specialties. Clinical decision support can help curtail inappropriate plasma use but needs to be part of a comprehensive strategy including audit and feedback for comprehensive, long-term changes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  8. PumpKin: A tool to find principal pathways in plasma chemical models

    Science.gov (United States)

    Markosyan, A. H.; Luque, A.; Gordillo-Vázquez, F. J.; Ebert, U.

    2014-10-01

    PumpKin is a software package to find all principal pathways, i.e. the dominant reaction sequences, in chemical reaction systems. Although many tools are available to integrate numerically arbitrarily complex chemical reaction systems, few tools exist in order to analyze the results and interpret them in relatively simple terms. In particular, due to the large disparity in the lifetimes of the interacting components, it is often useful to group reactions into pathways that recycle the fastest species. This allows a researcher to focus on the slow chemical dynamics, eliminating the shortest timescales. Based on the algorithm described by Lehmann (2004), PumpKin automates the process of finding such pathways, allowing the user to analyze complex kinetics and to understand the consumption and production of a certain species of interest. We designed PumpKin with an emphasis on plasma chemical systems but it can also be applied to atmospheric modeling and to industrial applications such as plasma medicine and plasma-assisted combustion.

  9. Improving plasma resistance and lowering roughness in an ArF photoresist by adding a chemical reaction inhibitor

    International Nuclear Information System (INIS)

    Jinnai, Butsurin; Uesugi, Takuji; Koyama, Koji; Samukawa, Seiji; Kato, Keisuke; Yasuda, Atsushi; Maeda, Shinichi; Momose, Hikaru

    2010-01-01

    Major challenges associated with 193 nm lithography using an ArF photoresist are low plasma resistance and roughness formation in the ArF photoresist during plasma processes. We have previously found decisive factors affecting the plasma resistance and roughness formation in an ArF photoresist: plasma resistance is determined by UV/VUV radiation, and roughness formation is dominated by chemical reactions. In this study, based on our findings on the interaction between plasma radiation species and ArF photoresist polymers, we proposed an ArF photoresist with a chemical reaction inhibitor, which can trap reactive species from the plasma, and characterized the performances of the resultant ArF photoresist through neutral beam experiments. Hindered amine light stabilizers, i.e. 4-hydroxy-2,2,6,6-tetramethyl-1-piperidinyloxy (HO-TEMPO), were used as the chemical reaction inhibitor. Etching rates of the ArF photoresist films were not dependent on the HO-TEMPO content in the irradiations without chemical reactions or under UV/VUV radiation. However, in the irradiation with chemical reactions, the etching rates of the ArF photoresist films decreased as the HO-TEMPO content increased. In addition, the surface roughness decreased with the increase in the additive amount of chemical reaction inhibitor. According to FTIR analysis, a chemical reaction inhibitor can inhibit the chemical reactions in ArF photoresist films through plasma radicals. These results indicate that a chemical reaction inhibitor is effective against chemical reactions, resulting in improved plasma resistance and less roughness in an ArF photoresist. These results also support our suggested mechanism of plasma resistance and roughness formation in an ArF photoresist.

  10. Chemical analysis of refractories by plasma spectrometry

    International Nuclear Information System (INIS)

    Coutinho, C.A.

    1990-01-01

    X-ray spectrometry has been, since the last two or three decades, the traditional procedure for the chemical analysis of refractories, due to its high degree of accuracy and speed to produce analytical results. An interesting alternative to X-ray fluorescence is provided by the Inductively Coupled Plasma Spectrometry technique, for those laboratories where wet chemistry facilities are already available or process control is not required at high speed, or investiment costs have to be low. This paper presents results obtained by plasma spectroscopy for the analysis of silico - aluminous refractories, showing calibration curves, precion and detection limits. Considerations and comparisons with X-ray fluorescence are also made. (author) [pt

  11. Laser thermal effect on silicon nitride ceramic based on thermo-chemical reaction with temperature-dependent thermo-physical parameters

    International Nuclear Information System (INIS)

    Pan, A.F.; Wang, W.J.; Mei, X.S.; Wang, K.D.; Zhao, W.Q.; Li, T.Q.

    2016-01-01

    Highlights: • A two-dimensional thermo-chemical reaction model is creatively built. • Thermal conductivity and heat capacity of β-Si_3N_4 are computed accurately. • The appropriate thermo-chemical reaction rate is fitted and reaction element length is set to assure the constringency. • The deepest ablated position was not the center of the ablated area due to plasma absorption. • The simulation results demonstrate the thermo-chemical process cant be simplified to be physical phase transition. - Abstract: In this study, a two-dimensional thermo-chemical reaction model with temperature-dependent thermo-physical parameters on Si_3N_4 with 10 ns laser was developed to investigate the ablated size, volume and surface morphology after single pulse. For model parameters, thermal conductivity and heat capacity of β-Si_3N_4 were obtained from first-principles calculations. Thermal-chemical reaction rate was fitted by collision theory, and then, reaction element length was deduced using the relationship between reaction rate and temperature distribution. Furthermore, plasma absorption related to energy loss was approximated as a function of electron concentration in Si_3N_4. It turned out that theoretical ablated volume and radius increased and then remained constant with increasing laser energy, and the maximum ablated depth was not in the center of the ablated zone. Moreover, the surface maximum temperature of Si_3N_4 was verified to be above 3000 K within pulse duration, and it was much higher than its thermal decomposition temperature of 1800 K, which indicated that Si_3N_4 was not ablated directly above the thermal decomposition temperature. Meanwhile, the single pulse ablation of Si_3N_4 was performed at different powers using a TEM_0_0 10 ns pulse Nd:YAG laser to validate the model. The model showed a satisfactory consistence between the experimental data and numerical predictions, presenting a new modeling technology that may significantly increase the

  12. Simultaneous measurement of 3 fluctuating plasma parameters

    International Nuclear Information System (INIS)

    Carlson, A.; Giannone, L.

    1991-01-01

    Langmuir triple probes can provide simultaneous measurements of n e , T e and V pl with good temporal and spatial resolution, and therefore are especially suited to detailed investigations of plasma turbulence in the scrape-off-layer. Unfortunately, the finite tip separation coupled with the fluctuating gradients prevents a simple interpretation of the results. We have developed a method using, essentially, two or more triple probes, which allows a good estimate of the three plasma parameters and their spatial derivatives at each point of time (assuming tip separation is much less than correlation length and dimensionless fluctuation levels are much less than unity). In particular, we can unambiguously measure the temperature fluctuations and the turbulent particle and heat flux. (author) 1 fig

  13. Simultaneous measurement of 3 fluctuating plasma parameters

    International Nuclear Information System (INIS)

    Carlson, A.; Giannone, L.

    1991-01-01

    Langmuir triple probes can provide simultaneous measurements of n e , T e , and V pl with good temporal and spatial resolution, and therefore are especially suited to detailed investigations of plasma turbulence in the scrape-off-layer. Unfortunately, the finite tip separation coupled with the fluctuating gradients prevents a simple interpretation of the results. We have developed a method using, essentially, two or more triple probes, which allows a good estimate of the three plasma parameters and their spatial derivatives at each point of time (assuming tip separation is much less than correlation length and dimensionless fluctuation levels are much less than unity). In particular, we can unambiguously measure the temperature fluctuations and the turbulent particle and heat flux. (orig.)

  14. Simultaneous measurement of 3 fluctuating plasma parameters

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, A; Giannone, L. (Max-Planck-Institut fuer Plasmaphysik, Garching (Germany))

    1991-01-01

    Langmuir triple probes can provide simultaneous measurements of n[sub e], T[sub e] and V[sub pl] with good temporal and spatial resolution, and therefore are especially suited to detailed investigations of plasma turbulence in the scrape-off-layer. Unfortunately, the finite tip separation coupled with the fluctuating gradients prevents a simple interpretation of the results. We have developed a method using, essentially, two or more triple probes, which allows a good estimate of the three plasma parameters and their spatial derivatives at each point of time (assuming tip separation is much less than correlation length and dimensionless fluctuation levels are much less than unity). In particular, we can unambiguously measure the temperature fluctuations and the turbulent particle and heat flux. (author) 1 fig.

  15. Fundamental aspects of plasma chemical physics kinetics

    CERN Document Server

    Capitelli, Mario; Colonna, Gianpiero; Esposito, Fabrizio; Gorse, Claudine; Hassouni, Khaled; Laricchiuta, Annarita; Longo, Savino

    2016-01-01

    Describing non-equilibrium "cold" plasmas through a chemical physics approach, this book uses the state-to-state plasma kinetics, which considers each internal state as a new species with its own cross sections. Extended atomic and molecular master equations are coupled with Boltzmann and Monte Carlo methods to solve the electron energy distribution function. Selected examples in different applied fields, such as microelectronics, fusion, and aerospace, are presented and discussed including the self-consistent kinetics in RF parallel plate reactors, the optimization of negative ion sources and the expansion of high enthalpy flows through nozzles of different geometries. The book will cover the main aspects of the state-to-state kinetic approach for the description of nonequilibrium cold plasmas, illustrating the more recent achievements in the development of kinetic models including the self-consistent coupling of master equations and Boltzmann equation for electron dynamics. To give a complete portrayal, the...

  16. Relationship of zinc concentrations in blood and seminal plasma with various semen parameters in infertile subjects

    International Nuclear Information System (INIS)

    Ali, H.; Ahmed, M.; Baig, M.; Ali, M.

    2007-01-01

    To find out relationship of zinc concentrations in blood and seminal plasma with various semen parameters between fertile and infertile men. (JPMC), Karachi and Department of Biochemistry. Basic Medical Sciences Institute, JPMC, Karachi. Fifty eight primary infertile male subjects, without any treatment, who had regular unprotected intercourse for at least 12 months without conception with their partners, aged 20-40 years, were selected from Infertility Clinic Jinnah Postgraduate Medical Center, Karachi. After semen analyses they were grouped as, oligospermic (30), and azoospermic (28). Twenty five known fertile male selected from general population and after semen analysis were taken as normospermic control group. Semen analyzed according to WHO criteria. Serum and seminal plasma zinc were estimated by 5Br. PAPS Colorimetric method. This study showed significant difference in serum and seminal zinc levels in normospermic, oligospermic (p<0.05) and azoospermic (p<0.005). Seminal plasma zinc showed a positive correlation with sperm count and negative with sperm motility in normospermic and oligospermic and negative correlation with volume, pH, WBC concentration in all three groups. There was no correlation found with sperm morphology. On the basis of the findings of this study and those of other reports, zinc may contribute to fertility through its significant effects on various semen parameters. It seems that the estimation of seminal plasma zinc may help in investigation and treatment of infertile males. (author)

  17. A lumped parameter model of plasma focus

    International Nuclear Information System (INIS)

    Gonzalez, Jose H.; Florido, Pablo C.; Bruzzone, H.; Clausse, Alejandro

    1999-01-01

    A lumped parameter model to estimate neutron emission of a plasma focus (PF) device is developed. The dynamic of the current sheet is calculated using a snowplow model, and the neutron production with the thermal fusion cross section for a deuterium filling gas. The results were contrasted as a function of the filling pressure with experimental measurements of a 3.68 KJ Mather-type PF. (author)

  18. Aqueous media treatment and decontamination of hazardous chemical and biological substances by contact plasma

    International Nuclear Information System (INIS)

    Pivovarov, A.; Kravchenko, A.; Kublanovsky, V.

    2009-01-01

    Usage of non-equilibrium contact plasma for processes of decontamination and neutralization in conditions of manifestation of chemical, biological and radiation terrorism takes on special significance due to portability of equipment and its mobility in places where toxic liquid media hazardous for people's health are located. Processes of decontamination of aqueous media, seminated with pathogenic microorganisms and viruses, treatment of water containing toxic heavy metals, cyanides, surface-active substances, and heavy radioactive elements, are investigated. Examples of activation processes in infected water and toxic aqueous solutions present convincing evidence of the way, how new quality technological approach for achievement of high enough degree of the said media treatment is used in each specific case. Among new properties of water activated as a result of action of non-equilibrium contact plasma, it is necessary to mention presence of cluster structure, confirmed by well-known spectral and physical-chemical methods, presence of peroxide compounds, active particles and radicals. Anti-microbial activity which is displayed under action of plasma in aqueous media (chemically pure water, drinking water, aqueous solutions of sodium chloride, potassium iodide, as well as other inorganic compounds) towards wide range of pathogenic and conventionally pathogenic microorganisms allows use them as reliable, accessible and low-cost preparations for increasing the degree of safety of food products. Combination of such processes with known methods of filtration and ultra-filtration gives an efficient and available complex capable of withstanding any threats, which may arise for population and living organisms. Present-day level of machine-building, electrical engineering, and electronics allows predict creation of industrial plasma installations, adapted to conditions of various terrorist threats, with minimized power consumption and optimized technological parameters

  19. Aqueous media treatment and decontamination of hazardous chemical and biological substances by contact plasma

    Energy Technology Data Exchange (ETDEWEB)

    Pivovarov, A; Kravchenko, A [Ukrainian State University of Chemical Engineering, Dnepropetrovsk (Ukraine); Kublanovsky, V [V. I. Vernadsky Institute of General and Inorganic Chemistry of National Academy of Science, Kiev (Ukraine)

    2009-07-01

    Usage of non-equilibrium contact plasma for processes of decontamination and neutralization in conditions of manifestation of chemical, biological and radiation terrorism takes on special significance due to portability of equipment and its mobility in places where toxic liquid media hazardous for people's health are located. Processes of decontamination of aqueous media, seminated with pathogenic microorganisms and viruses, treatment of water containing toxic heavy metals, cyanides, surface-active substances, and heavy radioactive elements, are investigated. Examples of activation processes in infected water and toxic aqueous solutions present convincing evidence of the way, how new quality technological approach for achievement of high enough degree of the said media treatment is used in each specific case. Among new properties of water activated as a result of action of non-equilibrium contact plasma, it is necessary to mention presence of cluster structure, confirmed by well-known spectral and physical-chemical methods, presence of peroxide compounds, active particles and radicals. Anti-microbial activity which is displayed under action of plasma in aqueous media (chemically pure water, drinking water, aqueous solutions of sodium chloride, potassium iodide, as well as other inorganic compounds) towards wide range of pathogenic and conventionally pathogenic microorganisms allows use them as reliable, accessible and low-cost preparations for increasing the degree of safety of food products. Combination of such processes with known methods of filtration and ultra-filtration gives an efficient and available complex capable of withstanding any threats, which may arise for population and living organisms. Present-day level of machine-building, electrical engineering, and electronics allows predict creation of industrial plasma installations, adapted to conditions of various terrorist threats, with minimized power consumption and optimized technological parameters

  20. Liquid assisted plasma enhanced chemical vapour deposition with a non-thermal plasma jet at atmospheric pressure

    Czech Academy of Sciences Publication Activity Database

    Schäfer, J.; Fricke, K.; Mika, Filip; Pokorná, Zuzana; Zajíčková, L.; Foest, R.

    2017-01-01

    Roč. 630, MAY 30 (2017), s. 71-78 ISSN 0040-6090 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : plasma jet * liquid assisted plasma enhanced chemical * vapour deposition * silicon oxide Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering OBOR OECD: Coating and films Impact factor: 1.879, year: 2016

  1. Scaling laws of design parameters for plasma wakefield accelerators

    International Nuclear Information System (INIS)

    Uhm, Han S.; Nam, In H.; Suk, Hyyong

    2012-01-01

    Simple scaling laws for the design parameters of plasma wakefield accelerators were obtained using a theoretical model, which were confirmed via particle simulation studies. It was found that the acceleration length was given by Δx=0.804λ p /(1−β g ), where λ p is the plasma wavelength and β g c the propagation velocity of the ion cavity. The acceleration energy can also be given by ΔE=(γ m −1)mc 2 =2.645mc 2 /(1−β g ), where m is the electron rest mass. As expected, the acceleration length and energy increase drastically as β g approached unity. These simple scaling laws can be very instrumental in the design of better-performing plasma wakefield accelerators. -- Highlights: ► Simple scaling laws for the design parameters of laser wakefield accelerators were obtained using a theoretical model. ► The scaling laws for acceleration length and acceleration energy were compared with particle-in-cell simulation results. ► The acceleration length and the energy increase drastically as β g approaches unity. ► These simple scaling laws can be very instrumental in the design of laser wakefield accelerators.

  2. Standardized 15N tracer methods for the evaluation of the plasma protein turnover in clinical practice. 1

    International Nuclear Information System (INIS)

    Bornhak, H.

    1984-01-01

    Methods for quantitative isolation of plasma proteins or groups of proteins (total plasma or serum proteins, fibrin, total globulines, α, β, γ-globolines, albumin) are described based on combination of chromatography with precipitation and extraction techniques. These methods are adapted to the special requirements of 15 N analysis. They can be performed in clinic-chemical standard laboratories without special apparatuses or devices. The described procedures are the biochemico-analytical basis for the quantitative evaluation of tracer kinetics data by means of mathematic modelling. (author)

  3. Surface temperature: A key parameter to control the propanethiol plasma polymer chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Thiry, Damien, E-mail: damien.thiry@umons.ac.be; Aparicio, Francisco J. [Chimie des Interactions Plasma Surface (ChIPS), CIRMAP, Université de Mons, 23 Place du Parc, B-7000 Mons (Belgium); Laha, Priya; Terryn, Herman [Research Group Electrochemical and Surface Engineering (SURF), Department of Materials and Chemistry (MACH), Pleinlaan 2, 1050 Brussel (Belgium); Snyders, Rony [Chimie des Interactions Plasma Surface (ChIPS), CIRMAP, Université de Mons, 23 Place du Parc, B-7000 Mons, Belgium and Materia Nova Research Center, Parc Initialis, B-7000 Mons (Belgium)

    2014-09-01

    In this work, the influence of the substrate temperature (T{sub s}) on the chemical composition of propanethiol plasma polymers was investigated for a given set of plasma conditions. In a first study, a decrease in the atomic sulfur content (at. %S) with the deposition time (t{sub d}) was observed. This behavior is explained by the heating of the growing film during deposition process, limiting the incorporation of stable sulfur-based molecules produced in the plasma. Experiments carried out by controlling the substrate temperature support this hypothesis. On the other hand, an empirical law relating the T{sub s} and the at. %S was established. This allows for the formation of gradient layer presenting a heterogeneous chemical composition along the thickness, as determined by depth profile analysis combining X-ray photoelectron spectroscopy and C{sub 60} ion gun sputtering. The experimental data fit with the one predicted from our empiric description. The whole set of our results provide new insights in the relationship between the substrate temperature and the sulfur content in sulfur-based plasma polymers, essential for future developments.

  4. Substrate Effect on Plasma Clean Efficiency in Plasma Enhanced Chemical Vapor Deposition System

    Directory of Open Access Journals (Sweden)

    Shiu-Ko JangJian

    2007-01-01

    Full Text Available The plasma clean in a plasma-enhanced chemical vapor deposition (PECVD system plays an important role to ensure the same chamber condition after numerous film depositions. The periodic and applicable plasma clean in deposition chamber also increases wafer yield due to less defect produced during the deposition process. In this study, the plasma clean rate (PCR of silicon oxide is investigated after the silicon nitride deposited on Cu and silicon oxide substrates by remote plasma system (RPS, respectively. The experimental results show that the PCR drastically decreases with Cu substrate compared to that with silicon oxide substrate after numerous silicon nitride depositions. To understand the substrate effect on PCR, the surface element analysis and bonding configuration are executed by X-ray photoelectron spectroscopy (XPS. The high resolution inductively coupled plasma mass spectrometer (HR-ICP-MS is used to analyze microelement of metal ions on the surface of shower head in the PECVD chamber. According to Cu substrate, the results show that micro Cu ion and the CuOx bonding can be detected on the surface of shower head. The Cu ion contamination might grab the fluorine radicals produced by NF3 ddissociation in the RPS and that induces the drastic decrease on PCR.

  5. Destruction of chemical warfare surrogates using a portable atmospheric pressure plasma jet

    Science.gov (United States)

    Škoro, Nikola; Puač, Nevena; Živković, Suzana; Krstić-Milošević, Dijana; Cvelbar, Uroš; Malović, Gordana; Petrović, Zoran Lj.

    2018-01-01

    Today's reality is connected with mitigation of threats from the new chemical and biological warfare agents. A novel investigation of cold plasmas in contact with liquids presented in this paper demonstrated that the chemically reactive environment produced by atmospheric pressure plasma jet (APPJ) is potentially capable of rapid destruction of chemical warfare agents in a broad spectrum. The decontamination of three different chemical warfare agent surrogates dissolved in liquid is investigated by using an easily transportable APPJ. The jet is powered by a kHz signal source connected to a low-voltage DC source and with He as working gas. The detailed investigation of electrical properties is performed for various plasmas at different distances from the sample. The measurements of plasma properties in situ are supported by the optical spectrometry measurements, whereas the high performance liquid chromatography measurements before and after the treatment of aqueous solutions of Malathion, Fenitrothion and Dimethyl Methylphosphonate. These solutions are used to evaluate destruction and its efficiency for specific neural agent simulants. The particular removal rates are found to be from 56% up to 96% during 10 min treatment. The data obtained provide basis to evaluate APPJ's efficiency at different operating conditions. The presented results are promising and could be improved with different operating conditions and optimization of the decontamination process.

  6. In Silico Prediction of Toxicokinetic Parameters for Environmentally Relevant Chemicals for Risk-Based Prioritization

    Science.gov (United States)

    Toxicokinetic (TK) models can address an important component of chemical risk assessments by helping bridge the gap between chemical exposure and measured toxicity endpoints. The metabolic clearance rate (CLint) and fraction of a chemical unbound by plasma proteins (Fub) are crit...

  7. Review: Plasma-enhanced chemical vapor deposition of nanocrystalline diamond

    Directory of Open Access Journals (Sweden)

    Katsuyuki Okada

    2007-01-01

    Full Text Available Nanocrystalline diamond films have attracted considerable attention because they have a low coefficient of friction and a low electron emission threshold voltage. In this paper, the author reviews the plasma-enhanced chemical vapor deposition (PE-CVD of nanocrystalline diamond and mainly focuses on the growth of nanocrystalline diamond by low-pressure PE-CVD. Nanocrystalline diamond particles of 200–700 nm diameter have been prepared in a 13.56 MHz low-pressure inductively coupled CH4/CO/H2 plasma. The bonding state of carbon atoms was investigated by ultraviolet-excited Raman spectroscopy. Electron energy loss spectroscopy identified sp2-bonded carbons around the 20–50 nm subgrains of nanocrystalline diamond particles. Plasma diagnostics using a Langmuir probe and the comparison with plasma simulation are also reviewed. The electron energy distribution functions are discussed by considering different inelastic interaction channels between electrons and heavy particles in a molecular CH4/H2 plasma.

  8. Triple-probe method applied to the direct display of plasma parameters in a supersonic flowing continuum plasma

    International Nuclear Information System (INIS)

    Ogram, G.L.; Chang, J.; Hobson, R.M.

    1979-01-01

    The calibration of electrostatic triple-probe voltage and current response in a supersonic continuum plasma has been carried out using a low-pressure shock tube. The electron temperature T/sub e/ and charge number density N/sub e/ are compared to probe voltage and current response, respectively, for a useful range of plasma parameters (1 13 13 is the nondimensional probe voltage). The dependence of probe response on Debye ratio R/sub p//lambda/sub D/ and various flow parameters was investigated. The probe voltage response was found to depend significantly on the Debye ratio. Expressions for electron temperature determination by triple probe are presented

  9. Cluster analysis to evaluate stable chemical elements and physical-chemical parameters behavior on uranium mining waste

    International Nuclear Information System (INIS)

    Pereira, Wagner de Souza; Py Junior, Delcy de Azevedo; Goncalves, Simone; Kelecom, Alphonse; Morais, Gustavo Ferrari de; Campelo, Emanuele Lazzaretti Cordova; Dores, Luis Augusto de Carvalho Bresser

    2011-01-01

    The Ore Treating Unit (UTM, in portuguese) is a deactivated uranium mine. A cluster analysis was used to evaluate the behavior of stable chemical elements and physical-chemical parameters in their effluents. The utilization of the cluster analysis proved itself effective in the assessment, allowing the identification of groups of chemical elements, physical-chemical parameters and their joint analysis (elements and parameters). As a result we may assert, based on data analysis, that there is a strong link between calcium and magnesium and between aluminum and rare-earth oxides on UTM's effluents. Sulphate was also identified as strongly linked to total and dissolved solids, and those to electrical conductivity. There were other associations, but not so strongly linked. Further gathering, to seasonal evaluation, are required in order to confirm those analysis. Additional statistical analysis (factor analysis) must be used to try to identify the origin of the identified groups on this analysis. (author)

  10. Cluster analysis to evaluate stable chemical elements and physical-chemical parameters behavior on uranium mining waste

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Wagner de Souza; Py Junior, Delcy de Azevedo; Goncalves, Simone, E-mail: wspereira@inb.gov.br [Unidade de Tratamento de Minerio (UTM/INB), Pocos de Caldas, MG (Brazil). Coordenacao de Protecao Radiologica. Grupo Multidisciplinar de Radioprotecao; Kelecom, Alphonse [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Inst. de Biologia. Lab. de Radiobiologia e Radiometria Pedro Lopes dos Santos; Morais, Gustavo Ferrari de; Campelo, Emanuele Lazzaretti Cordova [Unidade de Tratamento de Minerio (UTM/INB), Pocos de Caldas, MG (Brazil). Coordenacao de Desenvolvimento de Processos; Dores, Luis Augusto de Carvalho Bresser [Unidade de Tratamento de Minerio (UTM/INB), Pocos de Caldas, MG (Brazil). Gerencia de Descomissionamento

    2011-07-01

    The Ore Treating Unit (UTM, in portuguese) is a deactivated uranium mine. A cluster analysis was used to evaluate the behavior of stable chemical elements and physical-chemical parameters in their effluents. The utilization of the cluster analysis proved itself effective in the assessment, allowing the identification of groups of chemical elements, physical-chemical parameters and their joint analysis (elements and parameters). As a result we may assert, based on data analysis, that there is a strong link between calcium and magnesium and between aluminum and rare-earth oxides on UTM's effluents. Sulphate was also identified as strongly linked to total and dissolved solids, and those to electrical conductivity. There were other associations, but not so strongly linked. Further gathering, to seasonal evaluation, are required in order to confirm those analysis. Additional statistical analysis (factor analysis) must be used to try to identify the origin of the identified groups on this analysis. (author)

  11. Characteristics of nanosized zirconia prepared by plasma and chemical technique

    International Nuclear Information System (INIS)

    Kuznetsova, L.; Grabis, J.; Heidemane, G.

    2003-01-01

    The studied preparation method of zirconia using the plasma technique, azeotropic distillation and glycine routes ensure obtaining of nano sized powders with close average particle size but different crystallite size and phase composition. The sinterability of nano sized zirconia particles prepared by plasma technique or wet-chemical methods is similar and depends on the green density of pressed powders, improvement of with can be achieved by using of granulated precursors. (authors)

  12. [Clinical use of virally inactived plasma. The experience of Blood Transfusion Unit in Mantova, Italy].

    Science.gov (United States)

    Lepri, Debora; Capuzzo, Enrico; Mattioli, Anna Vittoria; Dall'Oglio, Daniela; Sgarioto, Vincenzo; Terenziani, Isabella; Caramaschi, Giacomo; Manzato, Franco; Franchini, Massimo

    2013-03-01

    Fresh Frozen Plasma (FFP) is a blood component whose clinical use is widespread worldwide. Transfusion safety of this product is ensured by legally obligatory tests. Although these tests are carried out on each plasma donation, safety levels can be further improved by using some technical procedures, such as, among others, methylene blue (MB) and solvent-detergent (SD) viral inactivation methods. The DMTE (Blood Transfusion Unit) in Mantova has used the pharmaceutical-like SD virally inactivated plasma since 2007 (Plasmasafe, Kedrion) as replacement of the PFC by each single donor. Guidelines for the usage of both products are the same. With the main aim of assessing the therapeutic effectiveness and safety of Plasmasafe, we decided to clinically monitor transfusions performed with this product on patients of the Intensive Care Unit at the city hospital in Mantova. In addition, we controlled some coagulation parameters (PT, aPTT, ATIII, Fibrinogen, PC, PS, FV, FVII, FVIII) before and 24 hours after the Plasmasafe infusion. From a clinical point of view, the use of Plasmasafe always led to a significant reduction, or complete stop, of the bleeding. No transfusion-related adverse events were recorded. As regards, the most relevant laboratory results, a marked increase in the above mentioned hemostatic parameters was detected. Furthermore, patients transfused with this product received a mean volume significantly lower than an historical cohort of patients treated with FFP (503 mL with Plasmasafe versus 1549 mL with FFP, Pcost-effective treatment, able to rapidly correct hemostatic abnormalities, for critical patients.

  13. Characterization of DBD plasma source for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Kuchenbecker, M; Vioel, W [University of Applied Sciences and Arts, Faculty of Natural Sciences and Technology, Von-Ossietzky-Str. 99, 37085 Goettingen (Germany); Bibinov, N; Awakowicz, P [Institute for Electrical Engineering and Plasma Technology, Ruhr-Universitaet Bochum, Universitaetstr. 150, 44780 Bochum (Germany); Kaemlimg, A; Wandke, D, E-mail: m.kuchenbecker@web.d, E-mail: Nikita.Bibinov@rub.d, E-mail: awakowicz@aept-ruhr-uni-bochum.d, E-mail: vioel@hawk-hhg.d [CINOGY GmbH, Max-Naeder-Str. 15, 37114 Duderstadt (Germany)

    2009-02-21

    The dielectric barrier discharge (DBD) plasma source for biomedical application is characterized using optical emission spectroscopy, plasma-chemical simulation and voltage-current measurements. This plasma source possesses only one electrode covered by ceramic. Human body or some other object with enough high electric capacitance or connected to ground can serve as the opposite electrode. DBD consists of a number of microdischarge channels distributed in the gas gap between the electrodes and on the surface of the dielectric. To characterize the plasma conditions in the DBD source, an aluminium plate is used as an opposite electrode. Electric parameters, the diameter of microdischarge channel and plasma parameters (electron distribution function and electron density) are determined. The gas temperature is measured in the microdischarge channel and calculated in afterglow phase. The heating of the opposite electrode is studied using probe measurement. The gas and plasma parameters in the microdischarge channel are studied at varied distances between electrodes. According to an energy balance study, the input microdischarge electric energy dissipates mainly in heating of electrodes (about 90%) and partially (about 10%) in the production of chemical active species (atoms and metastable molecules).

  14. Plasma nitridation optimization for sub-15 A gate dielectrics

    NARCIS (Netherlands)

    Cubaynes, F.N; Schmitz, Jurriaan; van der Marel, C.; Snijders, J.H.M.; Veloso, A.; Rothschild, A.; Olsen, C.; Date, L.

    The work investigates the impact of plasma nitridation process parameters upon the physical properties and upon the electrical performance of sub-15 A plasma nitrided gate dielectrics. The nitrogen distribution and chemical bonding of ultra-thin plasma nitrided films have been investigated using

  15. Coronal mass ejections and disturbances in solar wind plasma parameters in relation with geomagnetic storms

    International Nuclear Information System (INIS)

    Verma, P L; Singh, Puspraj; Singh, Preetam

    2014-01-01

    Coronal Mass Ejections (CMEs) are the drastic solar events in which huge amount of solar plasma materials are ejected into the heliosphere from the sun and are mainly responsible to generate large disturbances in solar wind plasma parameters and geomagnetic storms in geomagnetic field. We have studied geomagnetic storms, (Dst ≤-75 nT) observed during the period of 1997-2007 with Coronal Mass Ejections and disturbances in solar wind plasma parameters (solar wind temperature, velocity, density and interplanetary magnetic field) .We have inferred that most of the geomagnetic storms are associated with halo and partial halo Coronal Mass Ejections (CMEs).The association rate of halo and partial halo coronal mass ejections are found 72.37 % and 27.63 % respectively. Further we have concluded that geomagnetic storms are closely associated with the disturbances in solar wind plasma parameters. We have determined positive co-relation between magnitudes of geomagnetic storms and magnitude of jump in solar wind plasma temperature, jump in solar wind plasma density, jump in solar wind plasma velocity and jump in average interplanetary magnetic field with co-relation co-efficient 0 .35 between magnitude of geomagnetic storms and magnitude of jump in solar wind plasma temperature, 0.19 between magnitude of geomagnetic storms and magnitude of jump in solar wind density, 0.34 between magnitude of geomagnetic storms and magnitude of jump in solar wind plasma velocity, 0.66 between magnitude of geomagnetic storms and magnitude of jump in average interplanetary magnetic field respectively. We have concluded that geomagnetic storms are mainly caused by Coronal Mass Ejections and disturbances in solar wind plasma parameters that they generate.

  16. Clinical and Biological Predictors of Plasma Levels of Soluble RAGE in Critically Ill Patients: Secondary Analysis of a Prospective Multicenter Observational Study

    Directory of Open Access Journals (Sweden)

    Thibaut Pranal

    2018-01-01

    Full Text Available Rationale. Although soluble forms of the receptor for advanced glycation end products (RAGE have been recently proposed as biomarkers in multiple acute or chronic diseases, few studies evaluated the influence of usual clinical and biological parameters, or of patient characteristics and comorbidities, on circulating levels of soluble RAGE in the intensive care unit (ICU setting. Objectives. To determine, among clinical and biological parameters that are usually recorded upon ICU admission, which variables, if any, could be associated with plasma levels of soluble RAGE. Methods. Data for this ancillary study were prospectively obtained from adult patients with at least one ARDS risk factor upon ICU admission enrolled in a large multicenter observational study. At ICU admission, plasma levels of total soluble RAGE (sRAGE and endogenous secretory (esRAGE were measured by duplicate ELISA and baseline patient characteristics, comorbidities, and usual clinical and biological indices were recorded. After univariate analyses, significant variables were used in multivariate, multidimensional analyses. Measurements and Main Results. 294 patients were included in this ancillary study, among whom 62% were admitted for medical reasons, including septic shock (11%, coma (11%, and pneumonia (6%. Although some variables were associated with plasma levels of RAGE soluble forms in univariate analysis, multidimensional analyses showed no significant association between admission parameters and baseline plasma sRAGE or esRAGE. Conclusions. We found no obvious association between circulating levels of soluble RAGE and clinical and biological indices that are usually recorded upon ICU admission. This trial is registered with NCT02070536.

  17. Experimental setup for producing tungsten coated graphite tiles using plasma enhanced chemical vapor deposition technique for fusion plasma applications

    International Nuclear Information System (INIS)

    Chauhan, Sachin Singh; Sharma, Uttam; Choudhary, K.K.; Sanyasi, A.K.; Ghosh, J.; Sharma, Jayshree

    2013-01-01

    Plasma wall interaction (PWI) in fusion grade machines puts stringent demands on the choice of materials in terms of high heat load handling capabilities and low sputtering yields. Choice of suitable material still remains a challenge and open topic of research for the PWI community. Carbon fibre composites (CFC), Beryllium (Be), and Tungsten (W) are now being considered as first runners for the first wall components of future fusion machines. Tungsten is considered to be one of the suitable materials for the job because of its superior properties than carbon like low physical sputtering yield and high sputter energy threshold, high melting point, fairly high re-crystallization temperature, low fuel retention capabilities, low chemical sputtering with hydrogen and its isotopes and most importantly the reparability with various plasma techniques both ex-situ and in-situ. Plasma assisted chemical vapour deposition is considered among various techniques as the most preferable technique for fabricating tungsten coated graphite tiles to be used as tokamak first wall and target components. These coated tiles are more favourable compared to pure tungsten due to their light weight and easier machining. A system has been designed, fabricated and installed at SVITS, Indore for producing tungsten coated graphite tiles using Plasma Enhanced Chemical Vapor Deposition (PE-CVD) technique for Fusion plasma applications. The system contains a vacuum chamber, a turbo-molecular pump, two electrodes, vacuum gauges, mass analyzer, mass flow controllers and a RF power supply for producing the plasma using hydrogen gas. The graphite tiles will be put on one of the electrodes and WF6 gas will be inserted in a controlled manner in the hydrogen plasma to achieve the tungsten-coating with WF6 dissociation. The system is integrated at SVITS, Indore and a vacuum of the order of 3*10 -6 is achieved and glow discharge plasma has been created to test all the sub-systems. The system design with

  18. Chemical and physical reactions under thermal plasmas conditions

    International Nuclear Information System (INIS)

    Fauchais, P.; Vardelle, A.; Vardelle, M.; Coudert, J.F.

    1987-01-01

    Basic understanding of the involved phenomena lags far behind industrial development that requires now a better knowledge of the phenomena to achieve a better control of the process allowing to improve the quality of the products. Thus the authors try to precise what is their actual knowledge in the fields of: plasma generators design; plasma flow models with the following key points: laminar or turbulent flow, heat transfer to walls, 2D or 3D models, non equilibrium effects, mixing problems when chemical reactions are to be taken into account with very fast kinetics, electrode regions, data for transport properties and kinetic rates; nucleation problems; plasma flow characteristics measurements: temperature or temperatures and population of excited states (automatized emission spectroscopy, LIF, CARS) as well as flow velocity (LDA with small particles, Doppler effects...); plasma and particles momentum and heat transfer either with models taking into account particles size and injection velocity distributions, heat propagation, vaporization, Kundsen effect, turbulences ... or with measurements: particles velocity and flux distributions (Laser Anemometry) as well as surface temperature distributions (two colour pyrometry in flight statistical or not)

  19. Spectroscopic ellipsometry on Si/SiO2/graphene tri-layer system exposed to downstream hydrogen plasma: Effects of hydrogenation and chemical sputtering

    International Nuclear Information System (INIS)

    Eren, Baran; Fu, Wangyang; Marot, Laurent; Calame, Michel; Steiner, Roland; Meyer, Ernst

    2015-01-01

    In this work, the optical response of graphene to hydrogen plasma treatment is investigated with spectroscopic ellipsometry measurements. Although the electronic transport properties and Raman spectrum of graphene change after plasma hydrogenation, ellipsometric parameters of the Si/SiO2/graphene tri-layer system do not change. This is attributed to plasma hydrogenated graphene still being electrically conductive, since the light absorption of conducting 2D materials does not depend on the electronic band structure. A change in the light transmission can only be observed when higher energy hydrogen ions (30 eV) are employed, which chemically sputter the graphene layer. An optical contrast is still apparent after sputtering due to the remaining traces of graphene and hydrocarbons on the surface. In brief, plasma treatment does not change the light transmission of graphene; and when it does, this is actually due to plasma damage rather than plasma hydrogenation

  20. Hidden parameters in the plasma deposition of microcrystalline silicon solar cells

    NARCIS (Netherlands)

    van den Donker, M.N.; Rech, B.; Schmitz, R.; Klomfass, J.; Dingemans, G.; Finger, F.; Houben, L.; Kessels, W.M.M.; Sanden, van de M.C.M.

    2007-01-01

    The effect of process parameters on the plasma deposition of µc-Si:H solar cells is reviewed in this article. Several in situ diagnostics are presented, which can be used to study the process stability as an additional parameter in the deposition process. The diagnostics were used to investigate the

  1. Mode transition of power dissipation and plasma parameters in an asymmetric capacitive discharge

    International Nuclear Information System (INIS)

    Lee, Soo-Jin; Lee, Hyo-Chang; Bang, Jin-young; Oh, Seung-Ju; Chung, Chin-Wook

    2013-01-01

    Electrical characteristics and plasma parameters were experimentally investigated in asymmetric capacitively coupled plasma with various argon gas pressures. At a low discharge current region, the transferred power to the plasma was proportional to the current, while the transferred power increased proportionally to square of the current at a high discharge current region. The mode transition of power dissipation occurred at the lower discharge current region with the high gas pressure. At the low radio-frequency power or low discharge current, the plasma density increased linearly with the discharge current, while at the high power or high discharge current, the rate of an increase in the plasma density depended on the gas pressures. A transition of the discharge resistance was also found when the mode transition of the power dissipation occurred. These changes in the electrical characteristics and the plasma parameters were mainly caused by the power dissipation mode transition from the plasma bulk to the sheath in the capacitive discharge with the asymmetric electrode, which has extremely high self-bias voltages. - Highlights: • Mode transition of the power dissipation in an asymmetrical capacitive discharge • Evolution of the discharge power, electrode voltage, and discharge impedance • Electron temperature and plasma density on the power dissipation mode transition

  2. The impact of BMI on sperm parameters and the metabolite changes of seminal plasma concomitantly.

    Science.gov (United States)

    Guo, Dan; Wu, Wei; Tang, Qiuqin; Qiao, Shanlei; Chen, Yiqiu; Chen, Minjian; Teng, Mengying; Lu, Chuncheng; Ding, Hongjuan; Xia, Yankai; Hu, Lingqing; Chen, Daozhen; Sha, Jiahao; Wang, Xinru

    2017-07-25

    The development of male infertility increased rapidly worldwide, which coinciding with the epidemic of obesity. However, the impact of weight abnormalities on sperm quality is still contestable. To assess the correlation between BMI and sperm parameters, we searched relevant articles in PubMed, Embase, Web of science, and Wanfang database published until June 2015 without language restriction. Otherwise, we also recruited some participants who attended fertility clinic as well as some general populations in this report. We performed a systematic review and meta-analysis about BMI and sperm parameters containing total sperm count, concentration, semen volume and sperm motility (overall and progressive). Metabolomic analysis of seminal plasma was performed to explore the mechanism from a new perspective. This study found standardized weighted mean differences (SMD) in sperm parameters (total sperm count, sperm concentration, and semen volume) of abnormal weight groups decreased to different degree compared to normal weight. Dose-response analysis found SMD of sperm count, sperm concentration and semen volume respectively fell 2.4%, 1.3% and 2.0% compared with normal weight for every 5-unit increase in BMI. Metabolomic analysis of seminal plasma showed that spermidine and spermine were likely to play a vital role in the spermatogenesis progress. This systematic review with meta-analysis has confirmed there was a relationship between BMI and sperm quality, suggesting obesity may be a detrimental factor of male infertility.

  3. Temporal evolution of electron energy distribution function and plasma parameters in the afterglow of drifting magnetron plasma

    International Nuclear Information System (INIS)

    Seo, Sang-Hun; In, Jung-Hwan; Chang, Hong-Young

    2005-01-01

    The temporal behaviour of the electron energy distribution function (EEDF) and the plasma parameters such as electron density, electron temperature and plasma and floating potentials in a mid-frequency pulsed dc magnetron plasma are investigated using time-resolved probe measurements. A negative-voltage dc pulse with an average power of 160 W during the pulse-on period, a repetition frequency of 20 kHz and a duty cycle of 50% is applied to the cathode of a planar unbalanced magnetron discharge with a grounded substrate. The measured electron energy distribution is found to exhibit a bi-Maxwellian distribution, which can be resolved with the low-energy electron group and the high-energy tail part during the pulse-on period, and a Maxwellian distribution only with low-energy electrons as a consequence of initially rapid decay of the high-energy tail part during the pulse-off period. This characteristic evolution of the EEDF is reflected in the decay characteristics of the electron density and temperature in the afterglow. These parameters exhibit twofold decay represented by two characteristic decay times of an initial fast decay time τ 1 , and a subsequent slower decay time τ 2 in the afterglow when approximated with a bi-exponential function. While the initial fast decay times are of the order of 1 μs (τ T1 ∼ 0.99 μs and τ N1 ∼ 1.5 μs), the slower decay times are of the order of a few tens of microseconds (τ T2 ∼ 7 μs and τ N2 ∼ 40 μs). The temporal evolution of the plasma parameters are qualitatively explained by considering the formation mechanism of the bi-Maxwellian electron distribution function and the electron transports of these electron groups in bulk plasma

  4. Chemical modeling of a high-density inductively-coupled plasma reactor containing silane

    NARCIS (Netherlands)

    Kovalgin, Alexeij Y.; Boogaard, A.; Brunets, I.; Holleman, J.; Schmitz, Jurriaan

    We carried out the modeling of chemical reactions in a silane-containing remote Inductively Coupled Plasma Enhanced Chemical Vapor Deposition (ICPECVD) system, intended for deposition of silicon, silicon oxide, and silicon nitride layers. The required electron densities and Electron Energy

  5. Chemical Changes in Nonthermal Plasma-Treated N-Acetylcysteine (NAC) Solution and Their Contribution to Bacterial Inactivation.

    Science.gov (United States)

    Ercan, Utku K; Smith, Josh; Ji, Hai-Feng; Brooks, Ari D; Joshi, Suresh G

    2016-02-02

    In continuation of our previous reports on the broad-spectrum antimicrobial activity of atmospheric non-thermal dielectric barrier discharge (DBD) plasma treated N-Acetylcysteine (NAC) solution against planktonic and biofilm forms of different multidrug resistant microorganisms, we present here the chemical changes that mediate inactivation of Escherichia coli. In this study, the mechanism and products of the chemical reactions in plasma-treated NAC solution are shown. UV-visible spectrometry, FT-IR, NMR, and colorimetric assays were utilized for chemical characterization of plasma treated NAC solution. The characterization results were correlated with the antimicrobial assays using determined chemical species in solution in order to confirm the major species that are responsible for antimicrobial inactivation. Our results have revealed that plasma treatment of NAC solution creates predominantly reactive nitrogen species versus reactive oxygen species, and the generated peroxynitrite is responsible for significant bacterial inactivation.

  6. Temperature dependence on plasma-induced damage and chemical reactions in GaN etching processes using chlorine plasma

    Science.gov (United States)

    Liu, Zecheng; Ishikawa, Kenji; Imamura, Masato; Tsutsumi, Takayoshi; Kondo, Hiroki; Oda, Osamu; Sekine, Makoto; Hori, Masaru

    2018-06-01

    Plasma-induced damage (PID) on GaN was optimally reduced by high-temperature chlorine plasma etching. Energetic ion bombardments primarily induced PID involving stoichiometry, surface roughness, and photoluminescence (PL) degradation. Chemical reactions under ultraviolet (UV) irradiation and chlorine radical exposure at temperatures higher than 400 °C can be controlled by taking into account the synergism of simultaneous photon and radical irradiations to effectively reduce PID.

  7. A study of the potential of plasma processing in the chemical industry

    International Nuclear Information System (INIS)

    Estey, P.N.; Connolly, T.J.

    1984-01-01

    This work describes a systematic approach to determine the potential for plasma processing in the United States chemical industry. A model was developed that describes the physical inputs and outputs from a plasma based processing system. Based on these mass flows and the energy flows to the processor an economic assessment of the plasma processing system is made. This economic assessment which also includes the capital costs of the processor, can be used to determine if the plasma system is competitive with the conventional system

  8. Sticking non-stick: Surface and Structure control of Diamond-like Carbon in Plasma Enhanced Chemical Vapour Deposition

    Science.gov (United States)

    Jones, B. J.; Nelson, N.

    2016-10-01

    This short review article explores the practical use of diamond-like carbon (DLC) produced by plasma enhanced chemical vapour deposition (PECVD). Using as an example issues relating to the DLC coating of a hand-held surgical device, we draw on previous works using atomic force microscopy, X-ray photoelectron spectroscopy, Raman spectroscopy, scanning electron microscopy, tensiometry and electron paramagnetic resonance. Utilising data from these techniques, we examine the surface structure, substrate-film interface and thin film microstructure, such as sp2/sp3 ratio (graphitic/diamond-like bonding ratio) and sp2 clustering. We explore the variations in parameters describing these characteristics, and relate these to the final device properties such as friction, wear resistance, and diffusion barrier integrity. The material and device characteristics are linked to the initial plasma and substrate conditions.

  9. Sticking non-stick: Surface and Structure control of Diamond-like Carbon in Plasma Enhanced Chemical Vapour Deposition

    International Nuclear Information System (INIS)

    Jones, B J; Nelson, N

    2016-01-01

    This short review article explores the practical use of diamond-like carbon (DLC) produced by plasma enhanced chemical vapour deposition (PECVD). Using as an example issues relating to the DLC coating of a hand-held surgical device, we draw on previous works using atomic force microscopy, X-ray photoelectron spectroscopy, Raman spectroscopy, scanning electron microscopy, tensiometry and electron paramagnetic resonance. Utilising data from these techniques, we examine the surface structure, substrate-film interface and thin film microstructure, such as sp 2 /sp 3 ratio (graphitic/diamond-like bonding ratio) and sp 2 clustering. We explore the variations in parameters describing these characteristics, and relate these to the final device properties such as friction, wear resistance, and diffusion barrier integrity. The material and device characteristics are linked to the initial plasma and substrate conditions. (paper)

  10. Clinical significance of determination of serum NSE and plasma ET, IGF-II, CNP levels in patients with acute brain injury

    International Nuclear Information System (INIS)

    Chen Bo

    2010-01-01

    Objective: To investigate the clinical significance of changes of plasma ET, IGF-II, CNP and serum NSE contents in patients with acute brain injury. Methods: Serum contents of neuron specific enolase (NSE) were measured with chemiluminescence immunoassay and plasma endothelin (ET), insulin-like growth factor-II (IGF-II) and C-type natriuretic peptide (CNP) were measured with radioimmunoassay in 30 patients with acute brain injury and 35 controls. Results: Serum contents of NSE and plasma IGF-II, CNP were not much different in patients with mild brain injury from those in controls (P >0.05), but plasma contents of ET were already significantly higher in patients with mild brain injury than those in controls(P < 0.01). The serum NSE and plasma ET levels in patients with moderate and severe brain injury were significantly higher than those in patients with mild brain injury and controls (P < 0.01). Decrease of plasma levels of IGF-II and CNP was not significant in patients with mild brain injury (vs controls). However, the plasma levels of IGF-II and CNP were significantly lower in patients with moderate and severe brain injury than those in patients with mild brain injury and controls (P <0.01). As a whole, the magnitude of changes of these parameters was proportional to the severity of the injury. Conclusion: Changes of serum NSE and plasma IGF-II, ET and CNP levels were closely related to the pathological process of brain injury. Determination of these parameters was of clinical importance for evaluation of the severity of injury and outcome prediction. (authors)

  11. Plasma chemical and electrical modelling of a negative DC corona in pure oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Soria, C [Departamento de Electronica y Electromagnetismo, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Sevilla (Spain); Pontiga, F [Departamento de FIsica Aplicada II, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Sevilla (Spain); Castellanos, A [Departamento de Electronica y Electromagnetismo, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Sevilla (Spain)

    2004-02-01

    A complex plasma chemical and electrical model of a negative stationary wire-to-cylinder corona discharge in pure oxygen is presented. The corona discharge is assumed to have axial and azimuthal symmetry. The experimental current-voltage characteristic is required as input data, but there are no other adjustable or empirical parameters. The experimental validation of the results of the model comes from its prediction of the ozone concentration. The role played by different reactions and species is analysed in detail using the results of the simulation. The effect of the gas temperature and of the decomposition of ozone at the electrodes is also investigated. The agreement between the model and the experiments is excellent when the effect of ozone decomposition at the electrodes is taken into account.

  12. Plasma chemical and electrical modelling of a negative DC corona in pure oxygen

    International Nuclear Information System (INIS)

    Soria, C; Pontiga, F; Castellanos, A

    2004-01-01

    A complex plasma chemical and electrical model of a negative stationary wire-to-cylinder corona discharge in pure oxygen is presented. The corona discharge is assumed to have axial and azimuthal symmetry. The experimental current-voltage characteristic is required as input data, but there are no other adjustable or empirical parameters. The experimental validation of the results of the model comes from its prediction of the ozone concentration. The role played by different reactions and species is analysed in detail using the results of the simulation. The effect of the gas temperature and of the decomposition of ozone at the electrodes is also investigated. The agreement between the model and the experiments is excellent when the effect of ozone decomposition at the electrodes is taken into account

  13. Plasma flame for mass purification of contaminated air with chemical and biological warfare agents

    International Nuclear Information System (INIS)

    Uhm, Han S.; Shin, Dong H.; Hong, Yong C.

    2006-01-01

    An elimination of airborne simulated chemical and biological warfare agents was carried out by making use of a plasma flame made of atmospheric plasma and a fuel-burning flame, which can purify the interior air of a large volume in isolated spaces such as buildings, public transportation systems, and military vehicles. The plasma flame generator consists of a microwave plasma torch connected in series to a fuel injector and a reaction chamber. For example, a reaction chamber, with the dimensions of a 22 cm diameter and 30 cm length, purifies an airflow rate of 5000 lpm contaminated with toluene (the simulated chemical agent) and soot from a diesel engine (the simulated aerosol for biological agents). Large volumes of purification by the plasma flame will free mankind from the threat of airborne warfare agents. The plasma flame may also effectively purify air that is contaminated with volatile organic compounds, in addition to eliminating soot from diesel engines as an environmental application

  14. Diffusion in plasma: The Hall effect, compositional waves, and chemical spots

    Energy Technology Data Exchange (ETDEWEB)

    Urpin, V., E-mail: Vadim.urpin@uv.es [Ioffe Institute of Physics and Technology (Russian Federation)

    2017-03-15

    Diffusion caused by a combined influence of the electric current and Hall effect is considered, and it is argued that such diffusion can form inhomogeneities of a chemical composition in plasma. The considered mechanism can be responsible for the formation of element spots in laboratory and astrophysical plasmas. This current-driven diffusion can be accompanied by propagation of a particular type of waves in which the impurity number density oscillates alone. These compositional waves exist if the magnetic pressure in plasma is much greater than the gas pressure.

  15. The Influence of the Axial Magnetic Field Upon- the Coaxial Plasma Gun Parameters

    International Nuclear Information System (INIS)

    El-Aragi, G.M.; El-Demardash, A.

    2001-01-01

    This study concerns with the influence of an applied axial magnetic field upon the electrical parameters and on the brightness (luminance) of argon plasma. The brightness was measured by with a photomultiplier type of IP28 RCA. The experimental results are investigated with plasma gun device operated with argon gas at a pressure of 3.5 Torr. An axial time independent magnetic field with intensity of 550 G is introduced along the plasma current sheath axial region, within the annular space between the two coaxial electrodes. From the measurements of the discharge current I(t) and the voltage V(t), the electrical discharge parameters of the plasma gun device and the plasma current sheath implosion velocity are estimated, in normal mode of plasma gun operation and in the mode of presence external axial magnetic field. A comparison between these two modes is studied. It was found that the thickness of skin-layer δ about 0.01 cm and the wavelength λ, of the perturbation about 1.3 cm i.e. the instability has been satisfied. The growth rate γ of the instability about 10 6 sec -1 . (author)

  16. Temporal development and chemical efficiency of positive streamers in a large scale wire-plate reactor as a function of voltage waveform parameters

    Science.gov (United States)

    Winands, G. J. J.; Liu, Z.; Pemen, A. J. M.; van Heesch, E. J. M.; Yan, K.; van Veldhuizen, E. M.

    2006-07-01

    In this paper a large-scale pulsed corona system is described in which pulse parameters such as pulse rise-time, peak voltage, pulse width and energy per pulse can be varied. The chemical efficiency of the system is determined by measuring ozone production. The temporal and spatial development of the discharge streamers is recorded using an ICCD camera with a shortest exposure time of 5 ns. The camera can be triggered at any moment starting from the time the voltage pulse arrives on the reactor, with an accuracy of less than 1 ns. Measurements were performed on an industrial size wire-plate reactor. The influence of pulse parameters like pulse voltage, DC bias voltage, rise-time and pulse repetition rate on plasma generation was monitored. It was observed that for higher peak voltages, an increase could be seen in the primary streamer velocity, the growth of the primary streamer diameter, the light intensity and the number of streamers per unit length of corona wire. No significant separate influence of DC bias voltage level was observed as long as the total reactor voltage (pulse + DC bias) remained constant and the DC bias voltage remained below the DC corona onset. For those situations in which the plasma appearance changed (e.g. different streamer velocity, diameter, intensity), a change in ozone production was also observed. The best chemical yields were obtained for low voltage (55 kV), low energetic pulses (0.4 J/pulse): 60 g (kWh)-1. For high voltage (86 kV), high energetic pulses (2.3 J/pulse) the yield decreased to approximately 45 g (kWh)-1, still a high value for ozone production in ambient air (RH 42%). The pulse repetition rate has no influence on plasma generation and on chemical efficiency up to 400 pulses per second.

  17. Temporal development and chemical efficiency of positive streamers in a large scale wire-plate reactor as a function of voltage waveform parameters

    Energy Technology Data Exchange (ETDEWEB)

    Winands, G J J [EPS Group, Department of Electrical Engineering, Eindhoven University of Technology, 5600 MB, Eindhoven (Netherlands); Liu, Z [EPS Group, Department of Electrical Engineering, Eindhoven University of Technology, 5600 MB, Eindhoven (Netherlands); Pemen, A J M [EPS Group, Department of Electrical Engineering, Eindhoven University of Technology, 5600 MB, Eindhoven (Netherlands); Heesch, E J M van [EPS Group, Department of Electrical Engineering, Eindhoven University of Technology, 5600 MB, Eindhoven (Netherlands); Yan, K [EPS Group, Department of Electrical Engineering, Eindhoven University of Technology, 5600 MB, Eindhoven (Netherlands); Veldhuizen, E M van [EPG Group, Department of Applied Physics, Eindhoven University of Technology, 5600 MB, Eindhoven (Netherlands)

    2006-07-21

    In this paper a large-scale pulsed corona system is described in which pulse parameters such as pulse rise-time, peak voltage, pulse width and energy per pulse can be varied. The chemical efficiency of the system is determined by measuring ozone production. The temporal and spatial development of the discharge streamers is recorded using an ICCD camera with a shortest exposure time of 5 ns. The camera can be triggered at any moment starting from the time the voltage pulse arrives on the reactor, with an accuracy of less than 1 ns. Measurements were performed on an industrial size wire-plate reactor. The influence of pulse parameters like pulse voltage, DC bias voltage, rise-time and pulse repetition rate on plasma generation was monitored. It was observed that for higher peak voltages, an increase could be seen in the primary streamer velocity, the growth of the primary streamer diameter, the light intensity and the number of streamers per unit length of corona wire. No significant separate influence of DC bias voltage level was observed as long as the total reactor voltage (pulse + DC bias) remained constant and the DC bias voltage remained below the DC corona onset. For those situations in which the plasma appearance changed (e.g. different streamer velocity, diameter, intensity), a change in ozone production was also observed. The best chemical yields were obtained for low voltage (55 kV), low energetic pulses (0.4 J/pulse): 60 g (kWh){sup -1}. For high voltage (86 kV), high energetic pulses (2.3 J/pulse) the yield decreased to approximately 45 g (kWh){sup -1}, still a high value for ozone production in ambient air (RH 42%). The pulse repetition rate has no influence on plasma generation and on chemical efficiency up to 400 pulses per second.

  18. Temporal development and chemical efficiency of positive streamers in a large scale wire-plate reactor as a function of voltage waveform parameters

    International Nuclear Information System (INIS)

    Winands, G J J; Liu, Z; Pemen, A J M; Heesch, E J M van; Yan, K; Veldhuizen, E M van

    2006-01-01

    In this paper a large-scale pulsed corona system is described in which pulse parameters such as pulse rise-time, peak voltage, pulse width and energy per pulse can be varied. The chemical efficiency of the system is determined by measuring ozone production. The temporal and spatial development of the discharge streamers is recorded using an ICCD camera with a shortest exposure time of 5 ns. The camera can be triggered at any moment starting from the time the voltage pulse arrives on the reactor, with an accuracy of less than 1 ns. Measurements were performed on an industrial size wire-plate reactor. The influence of pulse parameters like pulse voltage, DC bias voltage, rise-time and pulse repetition rate on plasma generation was monitored. It was observed that for higher peak voltages, an increase could be seen in the primary streamer velocity, the growth of the primary streamer diameter, the light intensity and the number of streamers per unit length of corona wire. No significant separate influence of DC bias voltage level was observed as long as the total reactor voltage (pulse + DC bias) remained constant and the DC bias voltage remained below the DC corona onset. For those situations in which the plasma appearance changed (e.g. different streamer velocity, diameter, intensity), a change in ozone production was also observed. The best chemical yields were obtained for low voltage (55 kV), low energetic pulses (0.4 J/pulse): 60 g (kWh) -1 . For high voltage (86 kV), high energetic pulses (2.3 J/pulse) the yield decreased to approximately 45 g (kWh) -1 , still a high value for ozone production in ambient air (RH 42%). The pulse repetition rate has no influence on plasma generation and on chemical efficiency up to 400 pulses per second

  19. Spectroscopic ellipsometry on Si/SiO{sub 2}/graphene tri-layer system exposed to downstream hydrogen plasma: Effects of hydrogenation and chemical sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Eren, Baran [Department of Physics, University of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Fu, Wangyang; Marot, Laurent, E-mail: laurent.marot@unibas.ch; Calame, Michel; Steiner, Roland; Meyer, Ernst [Department of Physics, University of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland)

    2015-01-05

    In this work, the optical response of graphene to hydrogen plasma treatment is investigated with spectroscopic ellipsometry measurements. Although the electronic transport properties and Raman spectrum of graphene change after plasma hydrogenation, ellipsometric parameters of the Si/SiO2/graphene tri-layer system do not change. This is attributed to plasma hydrogenated graphene still being electrically conductive, since the light absorption of conducting 2D materials does not depend on the electronic band structure. A change in the light transmission can only be observed when higher energy hydrogen ions (30 eV) are employed, which chemically sputter the graphene layer. An optical contrast is still apparent after sputtering due to the remaining traces of graphene and hydrocarbons on the surface. In brief, plasma treatment does not change the light transmission of graphene; and when it does, this is actually due to plasma damage rather than plasma hydrogenation.

  20. Surface chemical changes of atmospheric pressure plasma treated rabbit fibres important for felting process

    Energy Technology Data Exchange (ETDEWEB)

    Štěpánová, Vlasta, E-mail: vstepanova@mail.muni.cz [Department of Physical Electronics, Faculty of Science Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Slavíček, Pavel; Stupavská, Monika; Jurmanová, Jana [Department of Physical Electronics, Faculty of Science Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Černák, Mirko [Department of Physical Electronics, Faculty of Science Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Department of Experimental Physics, Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynská dolina F2, 842 48 Bratislava (Slovakia)

    2015-11-15

    Graphical abstract: - Highlights: • Rabbit fibres plasma treatment is an effective method for fibres modification. • Atmospheric pressure plasma treatment is able to affect fibres properties. • Surface changes on fibres after plasma treatment were analysed via SEM, ATR-FTIR, XPS. • Significant increase of fibres wettability after plasma treatment was observed. • Plasma treatment at atmospheric pressure can replace the chemical treatment of fibres. - Abstract: We introduce the atmospheric pressure plasma treatment as a suitable procedure for in-line industrial application of rabbit fibres pre-treatment. Changes of rabbit fibre properties due to the plasma treatment were studied in order to develop new technology of plasma-based treatment before felting. Diffuse Coplanar Surface Barrier Discharge (DCSBD) in ambient air at atmospheric pressure was used for plasma treatment. Scanning electron microscopy was used for determination of the fibres morphology before and after plasma treatment. X-ray photoelectron spectroscopy and attenuated total reflectance-Fourier transform infrared spectroscopy were used for evaluation of reactive groups. The concentration of carbon decreased and conversely the concentration of nitrogen and oxygen increased after plasma treatment. Aging effect of plasma treated fibres was also investigated. Using Washburn method the significant increase of fibres wettability was observed after plasma treatment. New approach of pre-treatment of fibres before felting using plasma was developed. Plasma treatment of fibres at atmospheric pressure can replace the chemical method which consists of application of strong acids on fibres.

  1. Plasma effects in aligned carbon nanoflake growth by plasma-enhanced hot filament chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Wang, B.B. [College of Chemistry and Chemical Engineering, Chongqing University of Technology, 69 Hongguang Rd, Lijiatuo, Banan District, Chongqing 400054 (China); Zheng, K. [Institute of Microstructure and Properties of Advanced Materials, Beijing University of Technology, Beijing 100124 (China); Cheng, Q.J., E-mail: qijin.cheng@xmu.edu.cn [School of Energy Research, Xiamen University, Xiamen 361005 (China); Ostrikov, K. [Plasma Nanoscience Center Australia (PNCA), Manufacturing Flagship, Commonwealth Scientific and Industrial Research Organization, PO Box 218, Lindfield 2070, NSW (Australia); Institute for Future Environments and School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane 4000, QLD (Australia); Plasma Nanoscience, School of Physics, The University of Sydney, Sydney 2006, NSW (Australia)

    2015-01-15

    Highlights: • Plasma-specific effects in the growth of carbon nanoflakes (CNFs) are studied. • Electic field in the plasma sheath promotes separation of CNFs from the substrate. • The orentention of GNFs is related to the combined electic force and growth effects. • The high growth grates of aligned GNFs are plasma-related. - Abstract: Carbon nanofilms are directly grown on silicon substrates by plasma-enhanced hot filament chemical vapor deposition in methane environment. It is shown that the nanofilms are composed of aligned carbon nanoflakes by extensive investigation of experimental results of field emission scanning electron microscopy, micro-Raman spectroscopy and transmission electron microscopy. In comparison with the graphene-like films grown without plasmas, the carbon nanoflakes grow in an alignment mode and the growth rate of the films is increased. The effects of the plasma on the growth of the carbon nanofilms are studied. The plasma plays three main effects of (1) promoting the separation of the carbon nanoflakes from the silicon substrate, (2) accelerating the motion of hydrocarbon radicals, and (3) enhancing the deposition of hydrocarbon ions onto the substrate surface. Due to these plasma-specific effects, the carbon nanofilms can be formed from the aligned carbon nanoflakes with a high rate. These results advance our knowledge on the synthesis, properties and applications of graphene-based materials.

  2. Long-term urine biobanking: storage stability of clinical chemical parameters under moderate freezing conditions without use of preservatives.

    Science.gov (United States)

    Remer, Thomas; Montenegro-Bethancourt, Gabriela; Shi, Lijie

    2014-12-01

    To examine the long-term stability and validity of analyte concentrations of 21 clinical biochemistry parameters in 24-h urine samples stored for 12 or 15 yr at -22°C and preservative free. Healthy children's 24-h urine samples in which the respective analytes had been measured shortly after sample collection (baseline) were reanalyzed. Second measurement was performed after 12 yr (organic acids) and 15 yr (creatinine, urea, osmolality, iodine, nitrogen, anions, cations, acid-base parameters) with the same analytical methodology. Paired comparisons and correlations between the baseline and repeated measurements were done. Recovery rates were calculated. More than half of the analytes (creatinine, urea, iodine, nitrogen, sodium, potassium, magnesium, calcium, ammonium, bicarbonate, citric & uric acid) showed measurement values after >10 yr of storage not significantly different from baseline. 15 of the 21 parameters were highly correlated (r=0.99) between baseline and second measurement. Poorest correlation was r=0.77 for oxalate. Recovery ranged from 73% (oxalate) to 105% (phosphate). Our results suggest high long-term stability and measurement validity for numerous clinical chemistry parameters stored at -22°C without addition of any urine preservative. Prospective storage of urine aliquots at -22°C for periods even exceeding 10 yr, appears to be an acceptable and valid tool in epidemiological settings for later quantification of several urine analytes. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Evaluation of physico-chemical parameters of agricultural soils ...

    African Journals Online (AJOL)

    Evaluation of physico-chemical parameters of agricultural soils irrigated by the waters of the hydrolic basin of Sebou River and their influences on the transfer of trace elements into sugar crops (the case of sugar cane)

  4. Experimental study of a RF plasma source with helicon configuration in the mix Ar/H_2. Application to the chemical etching of carbon materials surfaces in the framework of the plasma-wall interactions studies of ITER's divertor

    International Nuclear Information System (INIS)

    Bieber, T.

    2012-01-01

    The issue of the interaction wall-plasma is important in thermonuclear devices. The purpose of this work is to design a very low pressure atomic plasma source in order to study chemical etching of carbon surfaces in the same conditions as edge plasma in tokamaks. The experimental work has consisted in 2 stages: first, the characterisation of the new helicon configuration reactor developed for this research and secondly the atomic hydrogen source used for the chemical etching. The first chapter recalls what thermonuclear fusion is. The helicon configuration reactor as well as its diagnostics (optical emission spectroscopy, laser induced fluorescence - LIF, and Langmuir probe) are described in the second chapter. The third chapter deals with the different coupling modes (RF power and plasma) identified in pure argon plasmas and how they are obtained by setting experimental parameters such as injected RF power, magnetic fields or pressure. The fourth chapter is dedicated to the study of the difference in behavior between the electronic density and the relative density of metastable Ar"+ ions. The last chapter presents the results in terms of mass losses of the carbon material surfaces obtained with the atomic hydrogen source. (A.C.)

  5. Modification of optical and electrical properties of chemical bath deposited CdS using plasma treatments

    International Nuclear Information System (INIS)

    Gonzalez, G.; Krishnan, B.; Avellaneda, D.; Castillo, G. Alan; Das Roy, T.K.; Shaji, S.

    2011-01-01

    Cadmium sulphide (CdS) is a well known n-type semiconductor that is widely used in solar cells. Here we report preparation and characterization of chemical bath deposited CdS thin films and modification of their optical and electrical properties using plasma treatments. CdS thin films were prepared from a chemical bath containing Cadmium chloride, Triethanolamine and Thiourea under various deposition conditions. Good quality thin films were obtained during deposition times of 5, 10 and 15 min. CdS thin films prepared for 10 min. were treated using a glow discharge plasma having nitrogen and argon carrier gases. The changes in morphology, optical and electrical properties of these plasma treated CdS thin films were analyzed in detail. The results obtained show that plasma treatment is an effective technique in modification of the optical and electrical properties of chemical bath deposited CdS thin films.

  6. Modification of optical and electrical properties of chemical bath deposited CdS using plasma treatments

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, G. [Facultad de Ingenieria Mecanica y Electrica, Universidad Autonoma de Nuevo Leon, San Nicolas de los Garza, Nuevo Leon, C.P 66450 (Mexico); Krishnan, B. [Facultad de Ingenieria Mecanica y Electrica, Universidad Autonoma de Nuevo Leon, San Nicolas de los Garza, Nuevo Leon, C.P 66450 (Mexico); CIIDIT, Universidad Autonoma de Nuevo Leon, Apodaca, Nuevo Leon (Mexico); Avellaneda, D.; Castillo, G. Alan; Das Roy, T.K. [Facultad de Ingenieria Mecanica y Electrica, Universidad Autonoma de Nuevo Leon, San Nicolas de los Garza, Nuevo Leon, C.P 66450 (Mexico); Shaji, S., E-mail: sshajis@yahoo.com [Facultad de Ingenieria Mecanica y Electrica, Universidad Autonoma de Nuevo Leon, San Nicolas de los Garza, Nuevo Leon, C.P 66450 (Mexico); CIIDIT, Universidad Autonoma de Nuevo Leon, Apodaca, Nuevo Leon (Mexico)

    2011-08-31

    Cadmium sulphide (CdS) is a well known n-type semiconductor that is widely used in solar cells. Here we report preparation and characterization of chemical bath deposited CdS thin films and modification of their optical and electrical properties using plasma treatments. CdS thin films were prepared from a chemical bath containing Cadmium chloride, Triethanolamine and Thiourea under various deposition conditions. Good quality thin films were obtained during deposition times of 5, 10 and 15 min. CdS thin films prepared for 10 min. were treated using a glow discharge plasma having nitrogen and argon carrier gases. The changes in morphology, optical and electrical properties of these plasma treated CdS thin films were analyzed in detail. The results obtained show that plasma treatment is an effective technique in modification of the optical and electrical properties of chemical bath deposited CdS thin films.

  7. Plasma-enhanced chemical vapor deposition of aluminum oxide using ultrashort precursor injection pulses

    NARCIS (Netherlands)

    Dingemans, G.; Sanden, van de M.C.M.; Kessels, W.M.M.

    2012-01-01

    An alternative plasma-enhanced chemical vapor deposition (PECVD) method is developed and applied for the deposition of high-quality aluminum oxide (AlOx) films. The PECVD method combines a continuous plasma with ultrashort precursor injection pulses. We demonstrate that the modulation of the

  8. The effect of plasma parameter on the bootstrap current of fast ions in neutral beam injection

    International Nuclear Information System (INIS)

    Huang Qianhong; Gong Xueyu; Cao Jinjia; Yang Lei

    2014-01-01

    The effect of plasma parameters on the distribution of net current density of fast ions produced by neutral beam injection is investigated in a large-aspect-ratio Tokamak with circular cross-section under specific parameters. Numerical results show that the value of net current density increases with the temperature of plasma increasing and decreases with the density of plasma increasing. The value of net current density is weakly affected by the effective charge number, but the peak of net current density moves towards edge plasma with effective charge number increasing. (authors)

  9. Effects of plasma jet parameters, ionization, thermal conduction, and radiation on stagnation conditions of an imploding plasma liner

    Science.gov (United States)

    Stanic, Milos

    The disciplines of High Energy Density Physics (HEDP) and Inertial Confinement Fusion (ICF) are characterized by hypervelocity implosions and strong shocks. The Plasma Liner Experiment (PLX) is focused on reaching HEDP and/or ICF relevant regimes in excess of 1 Mbar peak pressure by the merging and implosion of discrete plasma jets, as a potentially efficient path towards these extreme conditions in a laboratory. In this work we have presented the first 3D simulations of plasma liner, formation, and implosion by the merging of discrete plasma jets in which ionization, thermal conduction, and radiation are all included in the physics model. The study was conducted by utilizing a smoothed particle hydrodynamics code (SPHC) and was a part of the plasma liner experiment (PLX). The salient physics processes of liner formation and implosion are studied, namely vacuum propagation of plasma jets, merging of the jets (liner forming), implosion (liner collapsing), stagnation (peak pressure), and expansion (rarefaction wave disassembling the target). Radiative transport was found to significantly reduce the temperature of the liner during implosion, thus reducing the thermal expansion rates and leaving more pronounced gradients in the plasma liner during the implosion compared with ideal hydrodynamic simulations. These pronounced gradients lead to a greater sensitivity of initial jet geometry and symmetry on peak pressures obtained. Accounting for ionization and transport, many cases gave higher peak pressures than the ideal hydrodynamic simulations. Scaling laws were developed accordingly, creating a non-dimensional parameter space in which performance of an imploding plasma jet liner can be estimated. It is shown that HEDP regimes could be reached with ≈ 5 MJ of liner energy, which would translate to roughly 10 to 20 MJ of stored (capacitor) energy. This is a potentially significant improvement over the currently available means via ICF of achieving HEDP and nuclear

  10. Preparation of carbon nanotubes with different morphology by microwave plasma enhanced chemical vapour deposition

    Energy Technology Data Exchange (ETDEWEB)

    Duraia, El-Shazly M. [Suez Canal University, Faculty of Science, Physics Department, Ismailia (Egypt); Al-Farabi Kazakh National University, 71 Al-Farabi av., 050038 Almaty (Kazakhstan); Institute of Physics and Technology, Ibragimov Street 11, 050032 Almaty (Kazakhstan); Mansurov, Zulkhair [Al-Farabi Kazakh National University, 71 Al-Farabi av., 050038 Almaty (Kazakhstan); Tokmoldin, S.Zh. [Institute of Physics and Technology, Ibragimov Street 11, 050032 Almaty (Kazakhstan)

    2010-04-15

    In this work we present a part of our results about the preparation of carbon nanotube with different morphologies by using microwave plasma enhanced chemical vapour deposition MPECVD. Well aligned, curly, carbon nanosheets, coiled carbon sheets and carbon microcoils have been prepared. We have investigated the effect of the different growth condition parameters such as the growth temperature, pressure and the hydrogen to methane flow rate ratio on the morphology of the carbon nanotubes. The results showed that there is a great dependence of the morphology of carbon nanotubes on these parameters. The yield of the carbon microcoils was high when the growth temperature was 700 C. There is a linear relation between the growth rate and the methane to hydrogen ratio. The effect of the gas pressure on the CNTs was also studied. Our samples were investigated by scanning electron microscope and Raman spectroscopy (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  11. Parameter Estimates in Differential Equation Models for Chemical Kinetics

    Science.gov (United States)

    Winkel, Brian

    2011-01-01

    We discuss the need for devoting time in differential equations courses to modelling and the completion of the modelling process with efforts to estimate the parameters in the models using data. We estimate the parameters present in several differential equation models of chemical reactions of order n, where n = 0, 1, 2, and apply more general…

  12. Fast non-linear extraction of plasma equilibrium parameters using a neural network mapping

    International Nuclear Information System (INIS)

    Lister, J.B.; Schnurrenberger, H.

    1990-07-01

    The shaping of non-circular plasmas requires a non-linear mapping between the measured diagnostic signals and selected equilibrium parameters. The particular configuration of Neural Network known as the multi-layer perceptron provides a powerful and general technique for formulating an arbitrary continuous non-linear multi-dimensional mapping. This technique has been successfully applied to the extraction of equilibrium parameters from measurements of single-null diverted plasmas in the DIII-D tokamak; the results are compared with a purely linear mapping. The method is promising, and hardware implementation is straightforward. (author) 15 refs., 7 figs

  13. Haematological and Serum Bio-Chemical Parameters of West ...

    African Journals Online (AJOL)

    Haematological and Serum Bio-Chemical Parameters of West African Dwarf and Kalahari Red Goats in the Humid Tropics. ... Haematological results showed that white blood cell count, haemoglobin concentration, haematocrit, mean corpuscular volume, mean corpuscular haemoglobin and mean corpuscular haemoglobin ...

  14. Grafting of copolymer styrene maleic anhydride on poly(ethylene terephthalate) film by chemical reaction and by plasma method

    Energy Technology Data Exchange (ETDEWEB)

    Bigan, Muriel; Bigot, Julien [Laboratoire de Chimie Organique et Macromoleculaire (UMR 8009), Universite des Sciences et Technologies de Lille, 59655 Villeneuve d' Ascq Cedex (France); Mutel, Brigitte [Laboratoire de Genie des Procedes d' Interactions Fluides reactifs-Materiaux (UPRES-EA 3751), Batiment C5, Universite des Sciences et Technologies de Lille, 59655 Villeneuve d' Ascq Cedex (France)], E-mail: Brigitte.mutel@univ-lille1.fr; Coqueret, Xavier [Laboratoire Reactions Selectives et Applications (UMR-CNRS 6519) Universite de Reims Champagne-Ardennes, B.P. 1039, 51687 Reims Cedex 2 (France)

    2008-02-15

    This work deals with the chemical grafting of a styrene maleic anhydride copolymer on the surface of a previously hydrolyzed polyethylene terephthalate (PET) film 12 {mu}m thick via covalent bond. Two different ways are studied. The first one involves an activation of the hydrolyzed PET by the triethylamine before the grafting step. In the second one, the copolymer reacts with the 4-dimethylaminopyridine in order to form maleinyl pyridinium salt which reacts with alcohol function of the hydrolyzed PET. Characterization and quantification of the grafting are performed by Fourier transform infrared spectroscopy. Factorial experiment designs are used to optimize the process and to estimate experimental parameters effects. The opportunity to associate the chemical process to a cold remote nitrogen plasma one is also examined.

  15. Plasma parameter estimations for the Large Helical Device based on the gyro-reduced Bohm scaling

    International Nuclear Information System (INIS)

    Okamoto, Masao; Nakajima, Noriyoshi; Sugama, Hideo.

    1991-10-01

    A model of gyro-reduced Bohm scaling law is incorporated into a one-dimensional transport code to predict plasma parameters for the Large Helical Device (LHD). The transport code calculations reproduce well the LHD empirical scaling law and basic parameters and profiles of the LHD plasma are calculated. The amounts of toroidal currents (bootstrap current and beam-driven current) are also estimated. (author)

  16. Laboratory simulation of the formation of an ionospheric depletion using Keda Space Plasma EXperiment (KSPEX

    Directory of Open Access Journals (Sweden)

    Pengcheng Yu

    2017-10-01

    Full Text Available In the work, the formation of an ionospheric depletion was simulated in a controlled laboratory plasma. The experiment was performed by releasing chemical substance sulfur hexafluoride (SF6 into the pure argon discharge plasma. Results indicate that the plasma parameters change significantly after release of chemicals. The electron density is nearly depleted due to the sulfur hexafluoride-electron attachment reaction; and the electron temperature and space potential experience an increase due to the decrease of the electron density. Compared to the traditional active release experiments, the laboratory scheme can be more efficient, high repetition rate and simpler measurement of the varying plasma parameter after chemical releasing. Therefore, it can effective building the bridge between the theoretical work and real space observation.

  17. ASPCAP: THE APOGEE STELLAR PARAMETER AND CHEMICAL ABUNDANCES PIPELINE

    Energy Technology Data Exchange (ETDEWEB)

    García Pérez, Ana E.; Majewski, Steven R.; Shane, Neville; Sobeck, Jennifer; Troup, Nicholas [Department of Astronomy, University of Virginia, Charlottesville, VA 22904-4325 (United States); Prieto, Carlos Allende; Carrera, Ricardo; García-Hernández, D. A.; Zamora, Olga [Instituto de Astrofísica de Canarias, E-38205 La Laguna, Tenerife (Spain); Holtzman, Jon A. [New Mexico State University, Las Cruces, NM 88003 (United States); Shetrone, Matthew [University of Texas at Austin, McDonald Observatory, Fort Davis, TX 79734 (United States); Mészáros, Szabolcs [ELTE Gothard Astrophysical Observatory, H-9704 Szombathely, Szent Imre Herceg St. 112 (Hungary); Bizyaev, Dmitry [Apache Point Observatory, P.O. Box 59, Sunspot, NM 88349-0059 (United States); Cunha, Katia [Observatório Nacional, São Cristóvão, Rio de Janeiro (Brazil); Johnson, Jennifer A.; Weinberg, David H. [Department of Astronomy, The Ohio State University, Columbus, OH 43210 (United States); Nidever, David L. [Department of Astronomy, University of Michigan, Ann Arbor, MI 48109 (United States); Schiavon, Ricardo P. [Astrophysics Research Institute, Liverpool John Moores University, Egerton Wharf, Birkenhead, Wirral CH41 1LD (United Kingdom); Smith, Verne V. [National Optical Astronomy Observatories, Tucson, AZ 85719 (United States); Bovy, Jo, E-mail: agp@iac.es [Institute for Advanced Study, Einstein Drive, Princeton, NJ 08540 (United States); and others

    2016-06-01

    The Apache Point Observatory Galactic Evolution Experiment (APOGEE) has built the largest moderately high-resolution ( R  ≈ 22,500) spectroscopic map of the stars across the Milky Way, and including dust-obscured areas. The APOGEE Stellar Parameter and Chemical Abundances Pipeline (ASPCAP) is the software developed for the automated analysis of these spectra. ASPCAP determines atmospheric parameters and chemical abundances from observed spectra by comparing observed spectra to libraries of theoretical spectra, using χ {sup 2} minimization in a multidimensional parameter space. The package consists of a fortran90 code that does the actual minimization and a wrapper IDL code for book-keeping and data handling. This paper explains in detail the ASPCAP components and functionality, and presents results from a number of tests designed to check its performance. ASPCAP provides stellar effective temperatures, surface gravities, and metallicities precise to 2%, 0.1 dex, and 0.05 dex, respectively, for most APOGEE stars, which are predominantly giants. It also provides abundances for up to 15 chemical elements with various levels of precision, typically under 0.1 dex. The final data release (DR12) of the Sloan Digital Sky Survey III contains an APOGEE database of more than 150,000 stars. ASPCAP development continues in the SDSS-IV APOGEE-2 survey.

  18. ASPCAP: The APOGEE Stellar Parameter and Chemical Abundances Pipeline

    Science.gov (United States)

    García Pérez, Ana E.; Allende Prieto, Carlos; Holtzman, Jon A.; Shetrone, Matthew; Mészáros, Szabolcs; Bizyaev, Dmitry; Carrera, Ricardo; Cunha, Katia; García-Hernández, D. A.; Johnson, Jennifer A.; Majewski, Steven R.; Nidever, David L.; Schiavon, Ricardo P.; Shane, Neville; Smith, Verne V.; Sobeck, Jennifer; Troup, Nicholas; Zamora, Olga; Weinberg, David H.; Bovy, Jo; Eisenstein, Daniel J.; Feuillet, Diane; Frinchaboy, Peter M.; Hayden, Michael R.; Hearty, Fred R.; Nguyen, Duy C.; O'Connell, Robert W.; Pinsonneault, Marc H.; Wilson, John C.; Zasowski, Gail

    2016-06-01

    The Apache Point Observatory Galactic Evolution Experiment (APOGEE) has built the largest moderately high-resolution (R ≈ 22,500) spectroscopic map of the stars across the Milky Way, and including dust-obscured areas. The APOGEE Stellar Parameter and Chemical Abundances Pipeline (ASPCAP) is the software developed for the automated analysis of these spectra. ASPCAP determines atmospheric parameters and chemical abundances from observed spectra by comparing observed spectra to libraries of theoretical spectra, using χ2 minimization in a multidimensional parameter space. The package consists of a fortran90 code that does the actual minimization and a wrapper IDL code for book-keeping and data handling. This paper explains in detail the ASPCAP components and functionality, and presents results from a number of tests designed to check its performance. ASPCAP provides stellar effective temperatures, surface gravities, and metallicities precise to 2%, 0.1 dex, and 0.05 dex, respectively, for most APOGEE stars, which are predominantly giants. It also provides abundances for up to 15 chemical elements with various levels of precision, typically under 0.1 dex. The final data release (DR12) of the Sloan Digital Sky Survey III contains an APOGEE database of more than 150,000 stars. ASPCAP development continues in the SDSS-IV APOGEE-2 survey.

  19. Achieving uniform layer deposition by atmospheric-pressure plasma-enhanced chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae-Ok [Department of Plasma Engineering, Korea Institute of Machinery & Materials (KIMM), Daejeon 305-343 (Korea, Republic of); Kang, Woo Seok, E-mail: kang@kimm.re.kr [Department of Plasma Engineering, Korea Institute of Machinery & Materials (KIMM), Daejeon 305-343 (Korea, Republic of); Department of Environment & Energy Mechanical Engineering, University of Science & Technology (UST), Daejeon 305-350 (Korea, Republic of); Hur, Min; Lee, Jin Young [Department of Plasma Engineering, Korea Institute of Machinery & Materials (KIMM), Daejeon 305-343 (Korea, Republic of); Song, Young-Hoon [Department of Plasma Engineering, Korea Institute of Machinery & Materials (KIMM), Daejeon 305-343 (Korea, Republic of); Department of Environment & Energy Mechanical Engineering, University of Science & Technology (UST), Daejeon 305-350 (Korea, Republic of)

    2015-12-31

    This work investigates the use of plasma-enhanced chemical vapor deposition under atmospheric pressure for achieving uniform layer formation. Electrical and optical measurements demonstrated that the counterbalance between oxygen and precursors maintained the homogeneous discharge mode, while creating intermediate species for layer deposition. Several steps of the deposition process of the layers, which were processed on a stationary stage, were affected by flow stream and precursor depletion. This study showed that by changing the flow streamlines using substrate stage motion uniform layer deposition under atmospheric pressure can be achieved. - Highlights: • Zirconium oxide was deposited by atmospheric-pressure plasma-enhanced chemical vapor deposition. • Homogeneous plasma was maintained by counterbalancing between discharge gas and precursors. • Several deposition steps were observed affected by the gas flow stream and precursor depletion. • Thin film layer was uniformly grown when the substrate underwent a sweeping motion.

  20. The influence of pulse parameters on film composition during pulsed plasma polymerization of diaminocyclohexane

    Czech Academy of Sciences Publication Activity Database

    Choukourov, A.; Biederman, H.; Slavínská, D.; Trchová, Miroslava; Hollander, A.

    174-175, - (2003), s. 863-866 ISSN 0257-8972. [International Conference on Plasma Surface Engineering /8./. Garmisch-Partenkirchen, 09.09.2002-13.09.2002] R&D Projects: GA AV ČR KSK4050111 Keywords : plasma polymerization * chemical derivation * primary and secondary amino groups Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.410, year: 2003

  1. Degradation of sulfur dioxide using plasma technology; Degradacion de dioxido de azufre empleando tecnologia de plasma

    Energy Technology Data Exchange (ETDEWEB)

    Estrada M, N.; Garcia E, R. [Instituto Tecnologico de Toluca, Av. Tecnologico s/n, Ex-Rancho La Virgen, 52140 Metepec, Estado de Mexico (Mexico); Pacheco P, M.; Valdivia B, R.; Pacheco S, J., E-mail: nadiaemz@yahoo.com.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-07-01

    This paper presents the electro-chemical study performed for sulfur dioxide (SO{sub 2}) treatment using non thermal plasma coupled to a nano structured fluid bed enhancing the toxic gas removal and the adsorption of acids formed during plasma treatment, more of 80% of removal was obtained. Non thermal plasma was ignited by dielectric barrier discharge (Dbd). The research was developed through an analysis of the chemical kinetics of the process and experimental study of degradation; in each experiment the electrical parameters and the influence of carbon nano structures were monitored to establish the optimal conditions of degradation. We compared the theoretical and experimental results to conclude whether the proposed model is correct for degradation. (Author)

  2. Radioimmunoassay and chemical ionization/mass spectrometry compared for plasma cortisol determination

    International Nuclear Information System (INIS)

    Lindberg, C.; Johnson, S.; Hedner, P.; Gustafsson, A.

    1982-01-01

    A method is described for determination of cortisol in plasma and urine, based on chemical ionization/mass spectrometry with deuterium-labeled cortisol as the internal standard. The within-run precision (CV) was 2.5-5.7%, the between-run precision 4.6%. Results by this method were compared with those by a radioimmunological method (RIANEN Cortisol, New England Nuclear) for 395 plasma samples. The latter method gave significantly higher (approx. 25%) cortisol values

  3. In Silico Prediction of Toxicokinetic Parameters for Environmentally Relevant Chemicals with Application to Risk-Based Prioritization

    Science.gov (United States)

    Toxicokinetic (TK) models can help bridge the gap between chemical exposure and measured toxicity endpoints, thereby addressing an important component of chemical risk assessments. The fraction of a chemical unbound by plasma proteins (Fub) and metabolic clearance rate (CLint) ar...

  4. Impact of physico-chemical parameters on the physiological growth ...

    African Journals Online (AJOL)

    Impact of physico-chemical parameters on the physiological growth of Arthrospira (Spirulina platensis) exogenous strain UTEXLB2340. Yahia Mustafa A Fagiri, Aisha Salleh, Saifeldin Ahmed F El-Nagerabi ...

  5. Comparative Study of Plasma Parameters in Olive Ridley (Lepidochelys Olivacea and Hawksbill (Eretmochelys Imbricata During Nesting

    Directory of Open Access Journals (Sweden)

    A.Y.A. Alkindi

    2002-06-01

    Full Text Available The aim of this study is to investigate the role of plasma level parameters during nesting activity and provide data potentially useful to future studies on the dynamics of reproductive and stress hormones in the most endangered sea turtle species in the world. Plasma parameters in the sea turtles, olive ridley (Lipodochelys oliveacea and hawksbill (Eretmochelys imbricata from Masirah Island, Oman, were analyzed relative to nesting stress. To date, no study has been conducted on plasma parameter levels in sea turtles during nesting. Field observations were conducted under ideal temperature conditions. At the time of sampling, there was no significant difference for cloacal, sand, air or water temperature for the two species. Electrolytes (Cl¯, Ca++, K+, Na+ and Mg++, cholesterol, urea, uric acid and osmolarity were measured during nesting. Both species were observed to spend between 1.5 and 2.00 hours on the nesting grounds. Some had successful oviposition and completed all nesting phases, while others with incomplete nesting phases failed to oviposit their  eggs. Under both conditions, the turtles of both species had an exhaustive and stressful nesting exercise. Plasma parameter values, both intra-specifically and inter-specifically, were not significantly different for oviposited and non-oviposited turtles. This may indicate that both species have the same physiological adjustment relative to plasma parameters whether or not the turtles oviposited their eggs.

  6. Influence of operating parameters on surface properties of RF glow discharge oxygen plasma treated TiO{sub 2}/PET film for biomedical application

    Energy Technology Data Exchange (ETDEWEB)

    Pandiyaraj, K. Navaneetha, E-mail: dr.knpr@gmail.com [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L and T by pass, Chinniyam Palayam (post), Coimbatore 641062 (India); Deshmukh, R.R. [Department of Physics, Institute of Chemical Technology, Matunga, Mumbai 400 019 (India); Mahendiran, R. [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L and T by pass, Chinniyam Palayam (post), Coimbatore 641062 (India); Su, Pi-G [Department of Chemistry, Chinese Culture University, Taipei 111, Taiwan (China); Yassitepe, Emre; Shah, Ismat [Department of Physics and Astronomy, Department of Materials Science and Engineering, University of Delaware, 208 Dupont Hall, Newark (United States); Perni, Stefano [School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff (United Kingdom); Prokopovich, Polina [School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff (United Kingdom); Institute of Medical Engineering and Medical Physics, School of Engineering, Cardiff University (United Kingdom); Nadagouda, Mallikarjuna N., E-mail: Nadagouda.Mallikarjuna@epamail.epa.gov [The U.S. Environmental Protection Agency, ORD, NRMRL, WSWRD, 26W. Martin Luther King Drive, Cincinnati, OH 45268 (United States)

    2014-03-01

    In this paper, a thin transparent titania (TiO{sub 2}) film was coated on the surface of flexible poly(ethylene terephthalate) (PET) film using the sol–gel method. The surface properties of the obtained TiO{sub 2}/PET film were further improved by RF glow discharge oxygen plasma as a function of exposure time and discharge power. The changes in hydrophilicity of TiO{sub 2}/PET films were analyzed by contact angle measurements and surface energy. The influence of plasma on the surface of the TiO{sub 2}/PET films was analyzed by atomic force microscopy (AFM) as well as the change in chemical state and composition that were investigated by X-ray photo electron spectroscopy (XPS). The cytotoxicity of the TiO{sub 2}/PET films was analyzed using human osteoblast cells and the bacterial eradication behaviors of TiO{sub 2}/PET films were also evaluated against Staphylococcus bacteria. It was found that the surface roughness and incorporation of oxygen containing polar functional groups of the plasma treated TiO{sub 2}/PET films increased substantially as compared to the untreated one. Moreover the increased concentration of Ti{sup 3+} on the surface of plasma treated TiO{sub 2}/PET films was due to the transformation of chemical states (Ti{sup 4+} → Ti{sup 3+}). These morphological and chemical changes are responsible for enhanced hydrophilicity of the TiO{sub 2}/PET films. Furthermore, the plasma treated TiO{sub 2}/PET film exhibited no citotoxicity against osteoblast cells and antibacterial activity against Staphylococcus bacteria which can find application in manufacturing of biomedical devices. - Graphical abstract: Mechanism of plasma treatment on the surface of TiO{sub 2}/PET films. - Highlights: • Investigated the surface properties of TiO{sub 2}/PET films modified by O{sub 2} plasma • Studied the effect of operating parameters on surface properties of TiO{sub 2}/PET films • Mechanism of the plasma treatment on TiO{sub 2}/PET was clearly investigated.

  7. EFFECT OF PLASMA CUTTING PARAMETERS UPON SHAPES OF BEARING CURVE OF C45 STEEL SURFACE

    Directory of Open Access Journals (Sweden)

    Agnieszka Skoczylas

    2015-08-01

    Full Text Available The article presents the results of studies on the effect of plasma cutting technological parameters upon the shape of bearing curves and the parameters of the curve. The topography of surface formed by plasma cutting were analyzed. For measuring surface roughness and determining the bearing curve the appliance T8000 RC120 – 400 by Hommel-Etamic was used together with software.

  8. A comparison of diamond growth rate using in-liquid and conventional plasma chemical vapor deposition methods

    International Nuclear Information System (INIS)

    Takahashi, Yoshiyuki; Toyota, Hiromichi; Nomura, Shinfuku; Mukasa, Shinobu; Inoue, Toru

    2009-01-01

    In order to make high-speed deposition of diamond effective, diamond growth rates for gas-phase microwave plasma chemical vapor deposition and in-liquid microwave plasma chemical vapor deposition are compared. A mixed gas of methane and hydrogen is used as the source gas for the gas-phase deposition, and a methanol solution of ethanol is used as the source liquid for the in-liquid deposition. The experimental system pressure is in the range of 60-150 kPa. While the growth rate of diamond increases as the pressure increases, the amount of input microwave energy per unit volume of diamond is 1 kW h/mm 3 regardless of the method used. Since the in-liquid deposition method provides a superior cooling effect through the evaporation of the liquid itself, a higher electric input power can be applied to the electrodes under higher pressure environments. The growth rate of in-liquid microwave plasma chemical vapor deposition process is found to be greater than conventional gas-phase microwave plasma chemical vapor deposition process under the same pressure conditions.

  9. A comparison of diamond growth rate using in-liquid and conventional plasma chemical vapor deposition methods

    Science.gov (United States)

    Takahashi, Yoshiyuki; Toyota, Hiromichi; Nomura, Shinfuku; Mukasa, Shinobu; Inoue, Toru

    2009-06-01

    In order to make high-speed deposition of diamond effective, diamond growth rates for gas-phase microwave plasma chemical vapor deposition and in-liquid microwave plasma chemical vapor deposition are compared. A mixed gas of methane and hydrogen is used as the source gas for the gas-phase deposition, and a methanol solution of ethanol is used as the source liquid for the in-liquid deposition. The experimental system pressure is in the range of 60-150 kPa. While the growth rate of diamond increases as the pressure increases, the amount of input microwave energy per unit volume of diamond is 1 kW h/mm3 regardless of the method used. Since the in-liquid deposition method provides a superior cooling effect through the evaporation of the liquid itself, a higher electric input power can be applied to the electrodes under higher pressure environments. The growth rate of in-liquid microwave plasma chemical vapor deposition process is found to be greater than conventional gas-phase microwave plasma chemical vapor deposition process under the same pressure conditions.

  10. Patterned growth of carbon nanotubes obtained by high density plasma chemical vapor deposition

    Science.gov (United States)

    Mousinho, A. P.; Mansano, R. D.

    2015-03-01

    Patterned growth of carbon nanotubes by chemical vapor deposition represents an assembly approach to place and orient nanotubes at a stage as early as when they are synthesized. In this work, the carbon nanotubes were obtained at room temperature by High Density Plasmas Chemical Vapor Deposition (HDPCVD) system. This CVD system uses a new concept of plasma generation, where a planar coil coupled to an RF system for plasma generation was used with an electrostatic shield for plasma densification. In this mode, high density plasmas are obtained. We also report the patterned growth of carbon nanotubes on full 4-in Si wafers, using pure methane plasmas and iron as precursor material (seed). Photolithography processes were used to pattern the regions on the silicon wafers. The carbon nanotubes were characterized by micro-Raman spectroscopy, the spectra showed very single-walled carbon nanotubes axial vibration modes around 1590 cm-1 and radial breathing modes (RBM) around 120-400 cm-1, confirming that high quality of the carbon nanotubes obtained in this work. The carbon nanotubes were analyzed by atomic force microscopy and scanning electron microscopy too. The results showed that is possible obtain high-aligned carbon nanotubes with patterned growth on a silicon wafer with high reproducibility and control.

  11. Study of geometrical and operational parameters controlling the low frequency microjet atmospheric pressure plasma characteristics

    International Nuclear Information System (INIS)

    Kim, Dan Bee; Rhee, J. K.; Moon, S. Y.; Choe, W.

    2006-01-01

    Controllability of small size atmospheric pressure plasma generated at low frequency in a pin to dielectric plane electrode configuration was studied. It was shown that the plasma characteristics could be controlled by geometrical and operational parameters of the experiment. Under most circumstances, continuous glow discharges were observed, but both the corona and/or the dielectric barrier discharge characteristics were observed depending on the position of the pin electrode. The plasma size and the rotational temperature were also varied by the parameters. The rotational temperature was between 300 and 490 K, being low enough to treat thermally sensitive materials

  12. Fast non-linear extraction of plasma equilibrium parameters using a neural network mapping

    International Nuclear Information System (INIS)

    Lister, J.B.; Schnurrenberger, H.

    1991-01-01

    The shaping of non-circular plasmas requires a non-linear mapping between the measured diagnostic signals and selected equilibrium parameters. The particular configuration of neural network known as the multilayer perceptron provides a powerful and general technique for formulating an arbitrary continuous non-linear multi-dimensional mapping. This technique has been successfully applied to the extraction of equilibrium parameters from measurements of single-null diverted plasmas in the DIII-D tokamak; the results are compared with a purely linear mapping. The method is promising, and hardware implementation is straightforward. (author). 17 refs, 8 figs, 2 tab

  13. Plasma-enhanced chemical vapor deposition for YBCO film fabrication of superconducting fault-current limiter

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Byung Hyuk; Kim, Chan Joong

    2006-05-15

    Since the high-temperature superconductor of oxide type was founded, many researches and efforts have been performed for finding its application field. The YBCO superconducting film fabricated on economic metal substrate with uniform critical current density is considered as superconducting fault-current limiter (SFCL). There are physical and chemical processes to fabricate superconductor film, and it is understood that the chemical methods are more economic to deposit large area. Among them, chemical vapor deposition (CVD) is a promising deposition method in obtaining film uniformity. To solve the problems due to the high deposition temperature of thermal CVD, plasma-enhanced chemical vapor deposition (PECVD) is suggested. This report describes the principle and fabrication trend of SFCL, example of YBCO film deposition by PECVD method, and principle of plasma deposition.

  14. The clinical and mammographic features of plasma cell mastitis

    International Nuclear Information System (INIS)

    Wu Xiurong; Luo Xiaohua; Yu Xuming; Zhong Shan; Huang Yufan; Wu Xinyi; Lin Yubin

    2007-01-01

    Objective: To investigate the clinical and mammographic features of plasma cell mastitis. Methods: Twenty-five patients (28 lesions) with histologically confirmed plasma cell mastitis, aged from 26 to 70 years (mean age 41 years), were examined with X-ray mammography. The clinical manifestations and imaging features were retrospectively reviewed. Results: No case was in lactation. The painful irregular masses, ranged from 1.3 to 8cm in size, were found in 22 patients, while 3 patients with acute episode. Recurrent episodes of breast masses were noted in 4 patients. Based on the mammographic appearances, the plasma cell mastitis were classified as the following four types: inflammation-like type (2/28), ductal ectasia type (3/28), focal infiltration type (10/28) and nodular type (13/28). The valuable radiographic signs: (1) An asymmetrically increased density along the lactiferous duct with a flame-like appearance, inhomogeneous low density tubular structures and scattered stick-shape calcifications. (2) Architectural distortion and oil cysts formation in adjacent area, (3) Subareolar ductal ectasia. Conclusions: The clinical and mammographic characteristics of plasma cell mastitis are critical to avoiding unnecessary surgery. Histopathological result is needed for the diagnosis in patients highly suspected of malignancy. (authors)

  15. RF-plasma vapor deposition of siloxane on paper. Part 2: Chemical evolution of paper surface

    International Nuclear Information System (INIS)

    Sahin, Halil Turgut

    2013-01-01

    Highlights: ► Investigate the detailed RF-cold plasma surface modified paper by XPS and ATR-FTIR. ► Some chemical analysis of RF-cold plasma surface modified paper after RF plasma treatment. ► Identify the connection between RF plasma treatment and the surface chemistry of paper surface. - Abstract: Survey and high-resolution (HR) XPS studies indicate that OMCTSO plasma treatment created a new silicon containing functional groups and changed the hydroxyl content on the surface of paper. Four intense survey XPS spectrum peaks were observed for the OMCTSO plasma treated paper. They were the Si 2p at 100 eV, Si 2s at 160 eV, C 1s at 285 eV, and O 1s at 525 eV for the plasma modified surface. It was realized that the macromolecular chain-breaking mechanisms and plasma-induced etching processes control the number and the availability of OH-functionalities during OMCTSO plasma exposure on paper. The reaction, initiated by these species, depends mainly on the nature of chemicals in the plasma as well as on the energy level of the plasma and the nature of the surface effects in the modification of the paper. The ATR-FTIR spectrum of paper treated with OMCTSO plasma has characteristic absorption bands attributed to the Si-O and Si-O-Si formations on the surface.

  16. Development and Testing of a High Capacity Plasma Chemical Reactor in the Ukraine

    Energy Technology Data Exchange (ETDEWEB)

    Reilly, Raymond W.

    2012-07-30

    This project, Development and Testing of a High Capacity Plasma Chemical Reactor in the Ukraine was established at the Kharkiv Institute of Physics and Technology (KIPT). The associated CRADA was established with Campbell Applied Physics (CAP) located in El Dorado Hills, California. This project extends an earlier project involving both CAP and KIPT conducted under a separate CRADA. The initial project developed the basic Plasma Chemical Reactor (PCR) for generation of ozone gas. This project built upon the technology developed in the first project, greatly enhancing the output of the PCR while also improving reliability and system control.

  17. Study of plasma-material surface interaction using langmuir probe technique during plasma treatment

    International Nuclear Information System (INIS)

    Saloum, S.; Akel, M.

    2012-01-01

    In this study, we tried to understand the plasma-surface interactions by using Langmuir probes. Two different types of plasmas were studied, the first is the electropositive plasma in Argon and the second is the electronegative plasma in Sulfur Hexafluoride. In the first type, the effects of Argon gas pressure, the injection of Helium in the remote zone and the substrate bias on the measurements of the Electron Energy Probability Function (EEPF) and on the plasma parameters (electron density (n e ), effective electron temperature (T e ff), plasma potential (V p ) and floating potential (V f )) have been investigated. The obtained EEPFs and plasma parameters have been used to control two remote plasma processes. The first is the remote Plasma Enhanced Chemical Vapor Deposition (PE-CVD) of thin films, on silicon wafers, from Hexamethyldisiloxane (HMDSO) precursor diluted in the remote Ar-He plasma. The second is the pure Argon remote plasma treatment of polymethylmethacrylate (PMMA) polymer surface. In the second type, the plasma diagnostics were performed in the remote zone as a function of SF 6 flow rate, where relative concentrations of fluorine atoms were measured using actinometry optical emission spectroscopy; electron density, electron temperature and plasma potential were determined using single cylindrical Langmuir probe, positive ion flux and negative ion fraction were determined using an planar probe. The silicon etching process in SF 6 plasma was studied. (author)

  18. Study of plasma-material surface interaction using Langmuir probe technique during plasma treatment

    International Nuclear Information System (INIS)

    Saloum, S.; Akel, M.

    2009-06-01

    In this study, we tried to understand the plasma-surface interactions by using Langmuir probes. Two different types of plasmas were studied, the first is the electropositive plasma in Argon and the second is the electronegative plasma in Sulfur Hexafluoride. In the first type, the effects of Argon gas pressure, the injection of Helium in the remote zone and the substrate bias on the measurements of the Electron Energy Probability Function (EEPF) and on the plasma parameters (electron density (n e ), effective electron temperature (T e ff), plasma potential (V p ) and floating potential (V f )) have been investigated. The obtained EEPFs and plasma parameters have been used to control two remote plasma processes. The first is the remote Plasma Enhanced Chemical Vapor Deposition (PE-CVD) of thin films, on silicon wafers, from Hexamethyldisoloxane (HMDSO) precursor diluted in the remote Ar-He plasma. The second is the pure Argon remote plasma treatment of polymethylmethacrylate (PMMA) polymer surface. In the second type, the plasma diagnostics were performed in the remote zone as a function of SF 6 flow rate, where relative concentrations of fluorine atoms were measured using actinometry optical emission spectroscopy; electron density, electron temperature and plasma potential were determined using single cylindrical Langmuir probe, positive ion flux and negative ion fraction were determined using an planar probe. The silicon etching process in SF 6 plasma was studied. (author)

  19. Clinical Considerations in the Assessment of Adolescent Chemical Dependency.

    Science.gov (United States)

    Winters, Ken

    1990-01-01

    Discusses relevant research findings of clinical assessment of adolescent chemical dependency so that service providers can better address these concerns. Three major issues are discussed: the definition of adolescent chemical dependency, clinical domains of assessment (chemical use problem severity, precipitating and perpetuating risk factors,…

  20. Chemical reactions inside the plasma chamber of the SEAFP reactor plant models

    International Nuclear Information System (INIS)

    Gay, J.M.; Ebert, E.; Mazille, F.

    1995-01-01

    Loss of coolant or loss of vacuum accidents may lead to chemical reactions between the protecting materials of the plasma facing components and air or water. A production of energy, reaction products and hydrogen may be induced. The paper defines the operating conditions and chemical reactions and presents the main results from the underlying studies. (orig.)

  1. Cutoff effects of electron velocity distribution to the properties of plasma parameters near the plasma-sheath boundary

    International Nuclear Information System (INIS)

    Jelic, N.

    2011-01-01

    The plasma properties under high thermodynamic non-equilibrium condition, established due to the presence of electrically biased electrode, are investigated. Assumption of electron cut-off velocity distribution function (VDF), as done by Andrews and Varey in their investigations of the sheath region [J. Phys. A 3, 413 (1970)], has been extended here to both plasma and sheath regions. Analytic expressions for the moments of electron VDF, as well as for the electron screening temperature function dependence on the plasma-sheath local potential are derived. In deriving the ion velocity distribution the ''standard'' assumption of strict plasma quasineutrality, or equivalently vanishing of the plasma Debye length, is employed, whereas the ions are assumed to be generated at rest over the plasma region. However, unlike the standard approach of solving the plasma equation, where pure Boltzmann electron density profile is used, here we employ modified Boltzmann's electron density profile, due to cutoff effect of the electron velocity distribution. It is shown that under these conditions the quasineutrality equation solution is characterised by the electric field singularity for any negative value of the electrode bias potential as measured with respect to the plasma potential. The point of singularity i.e., the plasma length and its dependence on the electrode bias and sheath potential is established for the particular case of ionization profile mechanism proportional to the local electron density. Relevant parameters for the kinetic Bohm criterion are explicitly calculated for both ions and electrons, for arbitrary electrode bias.

  2. Relationship between plasma and tissue parameters of leucine metabolism

    International Nuclear Information System (INIS)

    Vazquez, J.A.; Paul, H.S.; Adibi, S.A.

    1986-01-01

    Using a primed continuous infusion of [1- 14 C] leucine, the authors investigated parameters of leucine metabolism in plasma, expired air, and tissues of fed and 48-hour starved rats. The ratios of muscle/plasma specific activity of α-ketoisocaproate (KIC) in fed and starved rats, respectively were not significantly different from one (1.07 +/- 0.14 and 0.97 +/- 0.10, mean +/- SE, 7 rats). The ratio of muscle/plasma specific activity of leucine was also not significantly different from one (0.86 +/- 0.11) in fed rats, but was significantly lower than one (0.80 +/- 0.07) in starved rats. The rate of leucine oxidation was approximately 32% higher when calculated based on plasma KIC rather than leucine specific activity. However, starvation significantly increased the rate of leucine oxidation with either specific activity. The rate of leucine incorporation into whole body protein was unaffected by starvation (32.7 +/- 3.5 vs 36.1 +/- 2.5 μmol/100 g/h), but the incorporation into total protein of liver (1350 +/- 140 vs 780 +/- 33 nmol) and of skeletal muscle (1940 +/- 220 vs 820 +/- 60 nmol) was significantly decreased. The authors conclude that a) leucine or KIC specific activity in muscle is better predicted by plasma KIC than leucine specific activity, and b) the tracer infusion technique is valid for the study of leucine oxidation but not for leucine incorporation into whole body protein

  3. Chemically different non-thermal plasmas target distinct cell death pathways

    Czech Academy of Sciences Publication Activity Database

    Lunov, O.; Zablotskyy, V.; Chrupina, O.; Lunova, M.; Jirsa, M.; Dejneka, A.; Kubinová, Šárka

    2017-01-01

    Roč. 7, apr (2017), s. 600 ISSN 2045-2322 R&D Projects: GA MŠk(CZ) LO1309 Institutional support: RVO:68378041 Keywords : chemically different * non-thermal plasmas * target distinct cell death pathways Subject RIV: FP - Other Medical Disciplines OBOR OECD: Biophysics Impact factor: 4.259, year: 2016

  4. Optimization of physico-chemical and nutritional parameters for ...

    African Journals Online (AJOL)

    Optimization of physico-chemical and nutritional parameters for pullulan production by a mutant of thermotolerant Aureobasidium pullulans, in fed batch ... minutes, having killing rate of 70% level, produced 6 g l-1 higher pullulan as compared to the wild type without loosing thermotolerant and non-melanin producing ability.

  5. Plasma-chemical simulation of negative corona near the inception voltage

    Science.gov (United States)

    Pontiga, Francisco; Duran-Olivencia, Francisco J.; Castellanos, Antonio

    2013-09-01

    The spatiotemporal development of Trichel pulses in oxygen between a spherical electrode and a grounded plane has been simulated using a fluid approximation that incorporates the plasma chemistry of the electrical discharge. Elementary plasma processes, such as ionization, electron attachment, electron detachment, recombination between ions and chemical reactions between neutral species, are all included in a chemical model consisting of 55 reactions between 8 different species (electrons, O2+,O2-,O3-,O-, O2, O, O3). Secondary emission at the cathode by the impact of positive ions and photons is also considered. The spatial distribution of species is computed in three dimensions (2D-axysimmetrical) by solving Poisson's equation for the electric field and the continuity equations for the species, with the inclusion of the chemical gain/loss rate due to the particle interaction. The results of the simulation reveal the interplay between the different negative ions during the development of every Trichel pulse, and the rate of production of atomic oxygen and ozone by the corona discharge. This work was supported by the Consejeria de Innovacion, Ciencia y Empresa (Junta de Andalucia) and by the Ministerio de Ciencia e Innovacion, Spain, within the European Regional Development Fund contracts FQM-4983 and FIS2011-25161.

  6. Plasma Biomarkers Discriminate Clinical Forms of Multiple Sclerosis

    Science.gov (United States)

    Tejera-Alhambra, Marta; Casrouge, Armanda; de Andrés, Clara; Seyfferth, Ansgar; Ramos-Medina, Rocío; Alonso, Bárbara; Vega, Janet; Fernández-Paredes, Lidia; Albert, Matthew L.; Sánchez-Ramón, Silvia

    2015-01-01

    Multiple sclerosis, the most common cause of neurological disability in young population after trauma, represents a significant public health burden. Current challenges associated with management of multiple sclerosis (MS) patients stem from the lack of biomarkers that might enable stratification of the different clinical forms of MS and thus prompt treatment for those patients with progressive MS, for whom there is currently no therapy available. In the present work we analyzed a set of thirty different plasma cytokines, chemokines and growth factors present in circulation of 129 MS patients with different clinical forms (relapsing remitting, secondary progressive and primary progressive MS) and 53 healthy controls, across two independent cohorts. The set of plasma analytes was quantified with Luminex xMAP technology and their predictive power regarding clinical outcome was evaluated both individually using ROC curves and in combination using logistic regression analysis. Our results from two independent cohorts of MS patients demonstrate that the divergent clinical and histology-based MS forms are associated with distinct profiles of circulating plasma protein biomarkers, with distinct signatures being composed of chemokines and growth/angiogenic factors. With this work, we propose that an evaluation of a set of 4 circulating biomarkers (HGF, Eotaxin/CCL11, EGF and MIP-1β/CCL4) in MS patients might serve as an effective tool in the diagnosis and more personalized therapeutic targeting of MS patients. PMID:26039252

  7. The scaling of edge parameters in jet with plasma input power

    International Nuclear Information System (INIS)

    Erents, S.K.; McCracken, G.M.; Harbour, P.J.; Clement, S.; Summers, D.D.R.; Tagle, J.A.; Kock, L. de

    1989-01-01

    The scaling of edge parameters of density and temperature with central density and ohmic power in JET has been presented previously for the discrete limiter geometry and more recently for the new belt limiter configuration. However, the scaling with plasma current (I p ) is difficult to interpret because varying I p does not only change the input power but also the safety factor qs and consequently the SOL thickness. The use of additional heating at constant current allows more direct observation of the effects of changing heating power. In this paper we present data in which the plasma input power is increased by ICRH, (Pt<20MW), using a 3MA target plasma, and compare data for different plasma currents using discrete and belt limiter geometries. Edge data is presented from Langmuir probes in tiles at the top of the torus, when the tokamak is operated in single null magnetic separatrix (divertor) mode, as well as for probes in the main plasma boundary to contrast these data with limiter data. (author) 3 refs., 4 figs

  8. Relationship between Lipids Levels of Serum and Seminal Plasma and Semen Parameters in 631 Chinese Subfertile Men.

    Directory of Open Access Journals (Sweden)

    Jin-Chun Lu

    Full Text Available This prospective study was designed to investigate the relationship between lipids levels in both serum and seminal plasma and semen parameters.631 subfertile men were enrolled. Their obesity-associated markers were measured, and semen parameters were analyzed. Also, seminal plasma and serum TC, TG, HDL and LDL and serum FFA, FSH, LH, total testosterone (TT, estradiol (E2 and SHBG levels were detected.Seminal plasma and serum TG, TC and LDL levels were positively related to age. Serum TC, TG and LDL were positively related to obesity-associated markers (P < 0.001, while only seminal plasma TG was positively related to them (P < 0.05. For lipids levels in serum and seminal plasma, only TG level had slightly positive correlation between them (r = 0.081, P = 0.042. There was no significant correlation between serum lipids levels and semen parameters. However, seminal plasma TG, TC, LDL and HDL levels were negatively related to one or several semen parameters, including semen volume (SV, sperm concentration (SC, total sperm count (TSC, sperm motility, progressive motility (PR and total normal-progressively motile sperm counts (TNPMS. Moreover, seminal plasma TG, TC, LDL and HDL levels in patients with oligospermatism, asthenospermia and teratozoospermia were higher than those with normal sperm concentration, motility or morphology. After adjusting age and serum LH, FSH, TT, E2 and SHBG levels, linear regression analysis showed that SV was still significantly correlated with seminal plasma LDL (P = 0.012, both of SC and TSC with seminal plasma HDL (P = 0.028 and 0.002, and both of PR and sperm motility with seminal plasma TC (P = 0.012 and 0.051.The abnormal metabolism of lipids in male reproductive system may contribute to male factor infertility.

  9. Scaling study of edge plasma parameters using a multi-device database

    International Nuclear Information System (INIS)

    Tsui, H.Y.W.; Miner, W.H.; Wootton, A.J.

    1995-01-01

    A database consisting of edge equilibrium, turbulence and transport related plasma parameters has been compiled. Scaling laws for edge density, electron temperature, and radial particle flux are derived in an initial study using a subset of data obtained from tokamaks Phaedrus-T, Tokamak de Varennes, TEXT and TEXT-U. A comparison of edge particle transport in divertor and limiter plasmas shows that the magnetic topology of a separatrix or a divertor improves particle confinement. The particle diffusion coefficient varies radially in a manner opposite to that of Bohm diffusion. ((orig.))

  10. Clinical characteristics of high plasma adiponectin and high plasma leptin as risk factors for arterial stiffness and related end-organ damage.

    Science.gov (United States)

    Kohara, Katsuhiko; Ochi, Masayuki; Okada, Yoko; Yamashita, Taiji; Ohara, Maya; Kato, Takeaki; Nagai, Tokihisa; Tabara, Yasuharu; Igase, Michiya; Miki, Tetsuro

    2014-08-01

    The relationship between plasma levels of adiponectin and cardiovascular events is inconclusive. We evaluated the clinical characteristics of people with high plasma adiponectin and high plasma leptin levels. Thousand seven hundred participants recruited from visitors to the Anti-Aging Doc were divided into four groups by combining the bipartiles of plasma adiponectin and leptin levels in men and women separately: AL, high adiponectin and high leptin; Al, high adiponectin and low leptin; al, low adiponectin and low leptin; aL, low adiponectin and high leptin. Body composition, including visceral fat area and thigh muscle cross-sectional area (CSA), brachial-ankle pulse wave velocity (baPWV), periventricular hyperintensity, and urinary albumin excretion, were determined. Twenty percent of the studied population fell within the AL group. This group had a significantly higher visceral fat area than the Al group. Thigh muscle CSA was lowest in the AL group among groups. baPWV, brain white matter lesions, and albuminuria findings in the AL group were significantly higher than those of the Al group. Multiple and logistic regression analyses with confounding parameters further confirmed that plasma adiponectin was not an independent determinant for brain and renal small vessel-related disease. These findings suggest that the plasma level of adiponectin alone is not enough for the risk stratification of cardiovascular disease. Leptin resistance associated with skeletal muscle loss in addition to obesity may need to be addressed to identify high risk people with high plasma adiponectin levels. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Effect of intralesional platelet-rich plasma (PRP) treatment on clinical and ultrasonographic parameters in equine naturally occurring superficial digital flexor tendinopathies - a randomized prospective controlled clinical trial.

    Science.gov (United States)

    Geburek, Florian; Gaus, Moritz; van Schie, Hans T M; Rohn, Karl; Stadler, Peter M

    2016-09-07

    Regenerative and anti-inflammatory effects on tendinopathies have been attributed to blood-derived biologicals. To date the evidence for the efficacy of autologous platelet-rich plasma (PRP) treatment of naturally occurring equine tendinopathies is limited. The purpose of this placebo-controlled clinical trial was to describe the effect of a single treatment of equine superficial digital flexor tendon (SDFT) disease with PRP on clinical and ultrasonographic parameters. Twenty horses with naturally occurring tendinopathies of forelimb SDFTs were randomly assigned to the PRP-treated group (n = 10) or control group (n = 10) after clinical and ultrasonographic examination. The SDFTs received an intralesional treatment with autologous PRP or were injected with saline, respectively (day 0). All horses participated in a standardized exercise programme and were re-examined clinically, with B-mode ultrasonography (5 times at regular intervals) and ultrasound tissue characterization (week 12 and 24 after treatment) until week 24. Long-term performance was estimated via telephone inquiry. Compared to day 0, lameness decreased significantly by week 8 after treatment with PRP and by week 12 in the control group. Ultrasonographically there was no difference in the summarized cross sectional area between the groups at any time point. Ultrasound tissue characterization showed that echo types representing disorganized matrix decreased significantly throughout the observation period in the PRP-treated group. Echo type II, representing discontinuous fascicles, not yet aligned into lines of stress was significantly higher 24 weeks after PRP treatment. Eighty percent of the PRP treated horses reached their previous or a higher level of performance after 12 months compared to 50 % in the CG. After 24 months these proportions were 60 % and 50 %, respectively. A single intralesional treatment with PRP up to 8 weeks after onset of clinical signs of tendinopathy contributes

  12. Diabatic models with transferrable parameters for generalized chemical reactions

    International Nuclear Information System (INIS)

    Reimers, Jeffrey R; McKemmish, Laura K; McKenzie, Ross H; Hush, Noel S

    2017-01-01

    Diabatic models applied to adiabatic electron-transfer theory yield many equations involving just a few parameters that connect ground-state geometries and vibration frequencies to excited-state transition energies and vibration frequencies to the rate constants for electron-transfer reactions, utilizing properties of the conical-intersection seam linking the ground and excited states through the Pseudo Jahn-Teller effect. We review how such simplicity in basic understanding can also be obtained for general chemical reactions. The key feature that must be recognized is that electron-transfer (or hole transfer) processes typically involve one electron (hole) moving between two orbitals, whereas general reactions typically involve two electrons or even four electrons for processes in aromatic molecules. Each additional moving electron leads to new high-energy but interrelated conical-intersection seams that distort the shape of the critical lowest-energy seam. Recognizing this feature shows how conical-intersection descriptors can be transferred between systems, and how general chemical reactions can be compared using the same set of simple parameters. Mathematical relationships are presented depicting how different conical-intersection seams relate to each other, showing that complex problems can be reduced into an effective interaction between the ground-state and a critical excited state to provide the first semi-quantitative implementation of Shaik’s “twin state” concept. Applications are made (i) demonstrating why the chemistry of the first-row elements is qualitatively so different to that of the second and later rows, (ii) deducing the bond-length alternation in hypothetical cyclohexatriene from the observed UV spectroscopy of benzene, (iii) demonstrating that commonly used procedures for modelling surface hopping based on inclusion of only the first-derivative correction to the Born-Oppenheimer approximation are valid in no region of the chemical

  13. Simulation of two-dimensional interior ballistics model of solid propellant electrothermal-chemical launch with discharge rod plasma generator

    Directory of Open Access Journals (Sweden)

    Yan-jie Ni

    2017-08-01

    Full Text Available Instead of the capillary plasma generator (CPG, a discharge rod plasma generator (DRPG is used in the 30 mm electrothermal-chemical (ETC gun to improve the ignition uniformity of the solid propellant. An axisymmetric two-dimensional interior ballistics model of the solid propellant ETC gun (2D-IB-SPETCG is presented to describe the process of the ETC launch. Both calculated pressure and projectile muzzle velocity accord well with the experimental results. The feasibility of the 2D-IB-SPETCG model is proved. Depending on the experimental data and initial parameters, detailed distribution of the ballistics parameters can be simulated. With the distribution of pressure and temperature of the gas phase and the propellant, the influence of plasma during the ignition process can be analyzed. Because of the radial flowing plasma, the propellant in the area of the DRPG is ignited within 0.01 ms, while all propellant in the chamber is ignited within 0.09 ms. The radial ignition delay time is much less than the axial delay time. During the ignition process, the radial pressure difference is less than 5  MPa at the place 0.025 m away from the breech. The radial ignition uniformity is proved. The temperature of the gas increases from several thousand K (conventional ignition to several ten thousand K (plasma ignition. Compare the distribution of the density and temperature of the gas, we know that low density and high temperature gas appears near the exits of the DRPG, while high density and low temperature gas appears at the wall near the breech. The simulation of the 2D-IB-SPETCG model is an effective way to investigate the interior ballistics process of the ETC launch. The 2D-IB-SPETC model can be used for prediction and improvement of experiments.

  14. Noise-resistant spectral features for retrieving foliar chemical parameters

    Science.gov (United States)

    Foliar chemical constituents are important indicators for understanding vegetation growing status and ecosystem functionality. Provided the noncontact and nondestructive traits, the hyperspectral analysis is a superior and efficient method for deriving these parameters. In practical implementation o...

  15. Study of the transport parameters of cloud lightning plasmas

    International Nuclear Information System (INIS)

    Chang, Z. S.; Yuan, P.; Zhao, N.

    2010-01-01

    Three spectra of cloud lightning have been acquired in Tibet (China) using a slitless grating spectrograph. The electrical conductivity, the electron thermal conductivity, and the electron thermal diffusivity of the cloud lightning, for the first time, are calculated by applying the transport theory of air plasma. In addition, we investigate the change behaviors of parameters (the temperature, the electron density, the electrical conductivity, the electron thermal conductivity, and the electron thermal diffusivity) in one of the cloud lightning channels. The result shows that these parameters decrease slightly along developing direction of the cloud lightning channel. Moreover, they represent similar sudden change behavior in tortuous positions and the branch of the cloud lightning channel.

  16. Physical-morphological and chemical changes leading to an increase in adhesion between plasma treated polyester fibres and a rubber matrix

    International Nuclear Information System (INIS)

    Krump, H.; Hudec, I.; Jasso, M.; Dayss, E.; Luyt, A.S.

    2006-01-01

    The effects of plasma treatment, used to increase adhesion strength between poly(ethylene terephtalate) (PET) fibres and a rubber matrix, were investigated and compared. Morphological changes as a result of atmospheric plasma treatment were observed using scanning electron microscopy (SEM) and atomic force microscopy (AFM). Wettability analysis using a surface energy evaluation system (SEE system) suggested that the plasma treated fibre was more wetting towards a polar liquid. When treated, these fibres showed a new lamellar crystallization, as shown by a new melting peak using differential scanning calorimetry (DSC). X-ray photoelectron spectroscopy (XPS) has been used to study the chemical effect of inert (argon), active and reactive (nitrogen and oxygen) microwave-plasma treatments of a PET surface. Reactive oxygen plasma treatment by a de-convolution method shows new chemical species that drastically alter the chemical reactivity of the PET surface. These studies have also shown that the surface population of chemical species formed after microwave-plasma treatment is dependent on the plasma gas. All these changes cause better adhesion strength of the PET fibres to the rubber matrix

  17. Assessment of Physicochemical and Major Chemical Parameters of ...

    African Journals Online (AJOL)

    The study was undertaken to assess the physicochemical and major chemical parameters of water springs in Iddo Wara Wale area of Dale Sadi district of Kellem Wollega, Oromia, Ethiopia. A total of 20 L samples were collected from five densely populated springs, namely: Ittisa, Abba Moga, Kersa, Ele Gonda and Merfata ...

  18. The material balance of process of plasma-chemical conversion of polymer wastes into synthesis gas

    International Nuclear Information System (INIS)

    Tazmeev, A Kh; Tazmeeva, R N

    2017-01-01

    The process of conversion of polymer wastes in the flow of water-steam plasma which are created by the liquid electrodes plasma generators was experimentally studied. The material balance was calculated. The regularities of the participating of hydrogen and oxygen which contained in the water-steam plasma, in formation of chemical compounds in the final products were revealed. (paper)

  19. The material balance of process of plasma-chemical conversion of polymer wastes into synthesis gas

    Science.gov (United States)

    Tazmeev, A. Kh; Tazmeeva, R. N.

    2017-01-01

    The process of conversion of polymer wastes in the flow of water-steam plasma which are created by the liquid electrodes plasma generators was experimentally studied. The material balance was calculated. The regularities of the participating of hydrogen and oxygen which contained in the water-steam plasma, in formation of chemical compounds in the final products were revealed.

  20. Stationary neoclassical profiles of plasma parameters in stellarators

    International Nuclear Information System (INIS)

    Danilkin, I.S.; Mineev, A.B.

    1991-01-01

    Peculiarities of neoclassical model of heat and particle transfer, occuring by calculations of plasma stationary profile parameters in stellarators are considered. The main peculiarity out of all consists in ineadequate compatibility with real physical conditions on the boundary, requiring application of supplementary 'anomalous' transfer or special (but technically possible) adjustment of particle and heat sources to achieve solution in form of 'correct' monotonically sloping profile. It is stated, that neoclassical theory does not provide for well-known ambiguity of solutions for ambipolar electrical field by search of monotonous stationary profiles supported by outside sources

  1. Degradation of sulfur dioxide using plasma technology

    International Nuclear Information System (INIS)

    Estrada M, N.; Garcia E, R.; Pacheco P, M.; Valdivia B, R.; Pacheco S, J.

    2013-01-01

    This paper presents the electro-chemical study performed for sulfur dioxide (SO 2 ) treatment using non thermal plasma coupled to a nano structured fluid bed enhancing the toxic gas removal and the adsorption of acids formed during plasma treatment, more of 80% of removal was obtained. Non thermal plasma was ignited by dielectric barrier discharge (Dbd). The research was developed through an analysis of the chemical kinetics of the process and experimental study of degradation; in each experiment the electrical parameters and the influence of carbon nano structures were monitored to establish the optimal conditions of degradation. We compared the theoretical and experimental results to conclude whether the proposed model is correct for degradation. (Author)

  2. Optical and electrical characteristics of plasma enhanced chemical vapor deposition boron carbonitride thin films derived from N-trimethylborazine precursor

    International Nuclear Information System (INIS)

    Sulyaeva, Veronica S.; Kosinova, Marina L.; Rumyantsev, Yurii M.; Kuznetsov, Fedor A.; Kesler, Valerii G.; Kirienko, Viktor V.

    2014-01-01

    Thin BC x N y films have been obtained by plasma enhanced chemical vapor deposition using N-trimethylborazine as a precursor. The films were deposited on Si(100) and fused silica substrates. The grown films were characterized by ellipsometry, Fourier transform infrared spectroscopy, scanning electron microscopy, X-ray energy dispersive spectroscopy, X-ray photoelectron spectroscopy, spectrophotometry, capacitance–voltage and current–voltage measurements. The deposition parameters, such as substrate temperature (373–973 K) and gas phase composition were varied. Low temperature BC x N y films were found to be high optical transparent layers in the range of 300–2000 nm, the transmittance as high as 93% has been achieved. BC x N y layers are dielectrics with dielectric constant k = 2.2–8.9 depending on the synthesis conditions. - Highlights: • Thin BC x N y films have been obtained by plasma enhanced chemical vapor deposition. • N-trimethylborazine was used as a precursor. • Low temperature BC x N y films were found to be high optical transparent layers (93%). • BC x N y layers are dielectrics with dielectric constant k = 2.2–8.9

  3. Remote plasma-enhanced metalorganic chemical vapor deposition of aluminum oxide thin films

    NARCIS (Netherlands)

    Volintiru, I.; Creatore, M.; Hemmen, van J.L.; Sanden, van de M.C.M.

    2008-01-01

    Aluminum oxide films were deposited using remote plasma-enhanced metalorganic chemical vapor deposition from oxygen/trimethylaluminum mixtures. Initial studies by in situ spectroscopic ellipsometry demonstrated that the aluminum oxide films deposited at temperatures

  4. Oxidation of the persistent compounds in the oxygen-hydrogen plasma

    International Nuclear Information System (INIS)

    Brozek, V.; Novak, M.; Vonka, P.; Kopecky, V.; Hrabovsky, M.

    1995-01-01

    The effectiveness of plasma-chemical decomposition of the persistent halogenated aliphatic hydrocarbons (CCl 4 , CF 2 Cl 2 , CF 3 Cl 3 and C 6 Cl 6 ) was examined by the analysis of emergent products in the dependence on the next parameters of the plasma-chemical reactor: power of the plasmatron; geometry of the plasmatic cone; velocity of flow of the gases by reaction chamber; stoichiometry of the ratio of the oxygen-air-water

  5. Dependence of electron beam instability growth rates on the beam-plasma system parameters

    International Nuclear Information System (INIS)

    Strangeway, R.J.

    1982-01-01

    Electron beam instabilites are studied by using a simple model for an electron beam streaming through a cold plasma, the beam being of finite width perpendicular to the ambient magnetic field. Through considerations of finite geometry and the coldness of the beam and background plasma, an instability similar to the two stream instability is assumed to be the means for wave growth in the system. Having found the maximum growth rate for one set of beam-plasma system parameters, this maximum growth rate is traced as these parameters are varied. The parameters that describe the system are the beam velocity (v/sub b/), electron gyrofrequency to ambient electron plasma frequency ratio (Ω/sub e//ω/sub p/e), the beam to background number density ratio (n/sub b//n/sub a/), and the beam width (a). When Ω/sub e//ω/sub p/e>1, a mode with Ω/sub e/<ω<ω/sub u/hr is found to be unstable, where Ω is the wave frequency and ω/sub u/hr is the upper hybrid resonance frequency. For low values of n/sub b//n/sub a/ and Ω/sub e/<ω/sub p/e, this mode is still present with ω/sub p/e<ω<ω/sub u/hr. If the beam density is large, n/sub b//n/sub a/approx. =1, the instability occures for frequencies just above the electron gyrofrequency. This mode may well be that observed in laboratory plasma before the system undergoes the beam-plasma discharge. There is another instability present, which occurs for ωapprox. =ω/sub p/e. The growth rates for this mode, which are generally larger than those found for the ωapprox. =ωuhr mode, are only weakly dependent on Ω/sub d//ω/sub p/e. That this mode is not always observed in the laboratory implies that some factors not considered in the present theory suppress this mode, specifically, finite beam length

  6. Effect of solar wind plasma parameters on space weather

    International Nuclear Information System (INIS)

    Rathore, Balveer S.; Gupta, Dinesh C.; Kaushik, Subhash C.

    2015-01-01

    Today's challenge for space weather research is to quantitatively predict the dynamics of the magnetosphere from measured solar wind and interplanetary magnetic field (IMF) conditions. Correlative studies between geomagnetic storms (GMSs) and the various interplanetary (IP) field/plasma parameters have been performed to search for the causes of geomagnetic activity and develop models for predicting the occurrence of GMSs, which are important for space weather predictions. We find a possible relation between GMSs and solar wind and IMF parameters in three different situations and also derived the linear relation for all parameters in three situations. On the basis of the present statistical study, we develop an empirical model. With the help of this model, we can predict all categories of GMSs. This model is based on the following fact: the total IMF B total can be used to trigger an alarm for GMSs, when sudden changes in total magnetic field B total occur. This is the first alarm condition for a storm's arrival. It is observed in the present study that the southward B z component of the IMF is an important factor for describing GMSs. A result of the paper is that the magnitude of B z is maximum neither during the initial phase (at the instant of the IP shock) nor during the main phase (at the instant of Disturbance storm time (Dst) minimum). It is seen in this study that there is a time delay between the maximum value of southward B z and the Dst minimum, and this time delay can be used in the prediction of the intensity of a magnetic storm two-three hours before the main phase of a GMS. A linear relation has been derived between the maximum value of the southward component of B z and the Dst, which is Dst = (−0.06) + (7.65) B z +t. Some auxiliary conditions should be fulfilled with this, for example the speed of the solar wind should, on average, be 350 km s −1 to 750 km s −1 , plasma β should be low and, most importantly, plasma temperature

  7. Modelling chemical reactions in dc plasma inside oxygen bubbles in water

    International Nuclear Information System (INIS)

    Takeuchi, N; Ishii, Y; Yasuoka, K

    2012-01-01

    Plasmas generated inside oxygen bubbles in water have been developed for water purification. Zero-dimensional numerical simulations were used to investigate the chemical reactions in plasmas driven by dc voltage. The numerical and experimental results of the concentrations of hydrogen peroxide and ozone in the solution were compared with a discharge current between 1 and 7 mA. Upon increasing the water vapour concentration inside bubbles, we saw from the numerical results that the concentration of hydrogen peroxide increased with discharge current, whereas the concentration of ozone decreased. This finding agreed with the experimental results. With an increase in the discharge current, the heat flux from the plasma to the solution increased, and a large amount of water was probably vaporized into the bubbles.

  8. Modelling chemical reactions in dc plasma inside oxygen bubbles in water

    Science.gov (United States)

    Takeuchi, N.; Ishii, Y.; Yasuoka, K.

    2012-02-01

    Plasmas generated inside oxygen bubbles in water have been developed for water purification. Zero-dimensional numerical simulations were used to investigate the chemical reactions in plasmas driven by dc voltage. The numerical and experimental results of the concentrations of hydrogen peroxide and ozone in the solution were compared with a discharge current between 1 and 7 mA. Upon increasing the water vapour concentration inside bubbles, we saw from the numerical results that the concentration of hydrogen peroxide increased with discharge current, whereas the concentration of ozone decreased. This finding agreed with the experimental results. With an increase in the discharge current, the heat flux from the plasma to the solution increased, and a large amount of water was probably vaporized into the bubbles.

  9. An enigmatic clinical presentation of plasma cell granuloma of the oral cavity

    Directory of Open Access Journals (Sweden)

    Pravesh Kumar Jhingta

    2018-01-01

    Full Text Available Plasma cell granuloma is a rare benign lesion characterized by the infiltration of plasma cells; primarily occurring in the lungs. It is also seen to occur in the brain, kidney stomach, heart, and so on but its intraoral occurrence is a rarity. This case report represents one of the uncommon locations in the oral cavity affected by plasma cell granuloma, its clinical and histological features, and establishes the differential diagnosis with other malignant or benign disease entities and planning the treatment accordingly. This report discusses the diagnostic enigma and the associated terminology of plasma cell granulomas and reinforces the need for performing biopsy and a histopathological or immune histochemical study, irrespective of the clinical features and clinical diagnosis of the lesion. In this case a 52-year-old female, presented with gingival enlargement in the mandibular anterior region, treated by excisional biopsy. Histological evaluation revealed plasma cell infiltrates in the connective tissue. The immune-histochemistry revealed kappa and lambda light chains with a polyclonal staining pattern, which confirmed the diagnosis of plasma cell granuloma.

  10. Chemically different non-thermal plasmas target distinct cell death pathways

    Czech Academy of Sciences Publication Activity Database

    Lunov, Oleg; Zablotskyy, Vitaliy A.; Churpita, Olexandr; Lunova, M.; Jirsa, M.; Dejneka, Alexandr; Kubinová, Šárka

    2017-01-01

    Roč. 7, č. 1 (2017), s. 1-17, č. článku 600. ISSN 2045-2322 Grant - others:AV ČR(CZ) Fellowship J. E. Purkyně Institutional support: RVO:68378271 Keywords : chemically different * non-thermal plasmas * target distinct cell death pathways Subject RIV: BO - Biophysics OBOR OECD: Biophysics Impact factor: 4.259, year: 2016

  11. The relationship between chemical structure and dielectric properties of plasma-enhanced chemical vapor deposited polymer thin films

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Hao [Materials Sci and Tech Applications, LLC, 409 Maple Springs Drive, Dayton OH 45458 (United States)]. E-mail: hao.jiang@wpafb.af.mil; Hong Lianggou [Materials Sci and Tech Applications, LLC, 409 Maple Springs Drive, Dayton OH 45458 (United States); Venkatasubramanian, N. [Research Institute, University of Dayton, 300 College Park, Dayton, OH 45469-0168 (United States); Grant, John T. [Research Institute, University of Dayton, 300 College Park, Dayton, OH 45469-0168 (United States); Eyink, Kurt [Air Force Research Laboratory, Materials Directorate, 3005 Hobson Way, Wright-Patterson Air Force Base, OH 45433-7707 (United States); Wiacek, Kevin [Air Force Research Laboratory, Propulsion Directorate, 1950 Fifth Street, Wright-Patterson Air Force Base, OH 45433-7251 (United States); Fries-Carr, Sandra [Air Force Research Laboratory, Propulsion Directorate, 1950 Fifth Street, Wright-Patterson Air Force Base, OH 45433-7251 (United States); Enlow, Jesse [Air Force Research Laboratory, Materials Directorate, 3005 Hobson Way, Wright-Patterson Air Force Base, OH 45433-7707 (United States); Bunning, Timothy J. [Air Force Research Laboratory, Materials Directorate, 3005 Hobson Way, Wright-Patterson Air Force Base, OH 45433-7707 (United States)

    2007-02-26

    Polymer dielectric films fabricated by plasma enhanced chemical vapor deposition (PECVD) have unique properties due to their dense crosslinked bulk structure. These spatially uniform films exhibit good adhesion to a variety of substrates, excellent chemical inertness, high thermal resistance, and are formed from an inexpensive, solvent-free, room temperature process. In this work, we studied the dielectric properties of plasma polymerized (PP) carbon-based polymer thin films prepared from two precursors, benzene and octafluorocyclobutane. Two different monomer feed locations, directly in the plasma zone or in the downstream region (DS) and two different pressures, 80 Pa (high pressure) or 6.7 Pa (low pressure), were used. The chemical structure of the PECVD films was examined by X-ray photoelectron spectroscopy and Fourier-transform infrared spectroscopy. The dielectric constant ({epsilon} {sub r}) and dielectric loss (tan {delta}) of the films were investigated over a range of frequencies up to 1 MHz and the dielectric strength (breakdown voltage) (F {sub b}) was characterized by the current-voltage method. Spectroscopic ellipsometry was performed to determine the film thickness and refractive index. Good dielectric properties were exhibited, as PP-benzene films formed in the high pressure, DS region showed a F{sub b} of 610 V/{mu}m, an {epsilon} {sub r} of 3.07, and a tan {delta} of 7.0 x 10{sup -3} at 1 kHz. The PECVD processing pressure has a significant effect on final film structure and the film's physical density has a strong impact on dielectric breakdown strength. Also noted was that the residual oxygen content in the PP-benzene films significantly affected the frequency dependences of the dielectric constant and loss.

  12. The relationship between chemical structure and dielectric properties of plasma-enhanced chemical vapor deposited polymer thin films

    International Nuclear Information System (INIS)

    Jiang Hao; Hong Lianggou; Venkatasubramanian, N.; Grant, John T.; Eyink, Kurt; Wiacek, Kevin; Fries-Carr, Sandra; Enlow, Jesse; Bunning, Timothy J.

    2007-01-01

    Polymer dielectric films fabricated by plasma enhanced chemical vapor deposition (PECVD) have unique properties due to their dense crosslinked bulk structure. These spatially uniform films exhibit good adhesion to a variety of substrates, excellent chemical inertness, high thermal resistance, and are formed from an inexpensive, solvent-free, room temperature process. In this work, we studied the dielectric properties of plasma polymerized (PP) carbon-based polymer thin films prepared from two precursors, benzene and octafluorocyclobutane. Two different monomer feed locations, directly in the plasma zone or in the downstream region (DS) and two different pressures, 80 Pa (high pressure) or 6.7 Pa (low pressure), were used. The chemical structure of the PECVD films was examined by X-ray photoelectron spectroscopy and Fourier-transform infrared spectroscopy. The dielectric constant (ε r ) and dielectric loss (tan δ) of the films were investigated over a range of frequencies up to 1 MHz and the dielectric strength (breakdown voltage) (F b ) was characterized by the current-voltage method. Spectroscopic ellipsometry was performed to determine the film thickness and refractive index. Good dielectric properties were exhibited, as PP-benzene films formed in the high pressure, DS region showed a F b of 610 V/μm, an ε r of 3.07, and a tan δ of 7.0 x 10 -3 at 1 kHz. The PECVD processing pressure has a significant effect on final film structure and the film's physical density has a strong impact on dielectric breakdown strength. Also noted was that the residual oxygen content in the PP-benzene films significantly affected the frequency dependences of the dielectric constant and loss

  13. L-carnitine plasma levels in dogs and cats. A diagnostic parameter?

    International Nuclear Information System (INIS)

    Fischer, J.

    1993-04-01

    The relation between levels of carnitine in plasma and lesions of organs should be demonstrated. 52 dogs and 58 cats examined in veterinary clinics for several reasons and routinely screened for blood chemistry also were analysed for free plasma carnitine by a radiocarbon method. Increased carnitine levels were observed in both species in case of heart, liver and kidney disorders. Additionally the influence of food intake on carnitine levels in dogs was studied. Postprandial changes were insignificant. Because of lack of information about carnitine levels in cats and changes with age plasma carnitine was determined in cats and kittens. The range of normal values was 8.2 to 24.2 μmol/l without any significance of age

  14. Physico-chemical study of coating plasma duplex alumina/hydroxyapatite for medical applications relation elaboration/structure/properties(dissolution/adherence/residual constraints)

    International Nuclear Information System (INIS)

    Demonet, N.

    1998-01-01

    The physico-chemical behavior of porous ceramics depositing is studied in order to use them to favour the biological fixing of hip prosthesis fixed without cement. Alumina depositing, hydroxyapatite depositing and duplex (the both together) have been realized by plasma projection on a substrate in Ti-6Al-V. Tests of dissolution have been made. An original method of sound followed by radioactive tracers has allowed to establish an order of phases degradation and to consider the kinetics of calcium ions in function of several parameters of tests. (N.C.)

  15. Physico-chemical parameters and heavy metal contents of Ibuya ...

    African Journals Online (AJOL)

    The physico-chemical parameters and heavy metal contents of Ibuya River were investigated between September 2012 and August 2013 from four stations using standard methods to etermine acceptable water quality standards and evaluate possible sustainability of a thriving fisheries cum tourist sport fishing venture.

  16. Determination of chemical solute transport parameters effecting radiostrontium interbed sediments

    International Nuclear Information System (INIS)

    Hemming, C.; Bunde, R.L.; Rosentreter, J.J.

    1993-01-01

    The extent to which radionuclides migrate in an aquifer system is a function of various physical, chemical, and biological processes. A measure of this migration rate is of primary concern when locating suitable storage sites for such species. Parameters including water-rock interactions, infiltration rates, chemical phase modification, and biochemical reactions all affect solute transport. While these different types of chemical reactions can influence solute transport in subsurface waters, distribution coefficients (Kd) can be send to effectively summarize the net chemical factors which dictate transport efficiency. This coefficient describes the partitioning of the solute between the solution and solid phase. Methodology used in determining and interpreting the distribution coefficient for radiostrontium in well characterized sediments will be presented

  17. The component content of active particles in a plasma-chemical reactor based on volume barrier discharge

    Science.gov (United States)

    Soloshenko, I. A.; Tsiolko, V. V.; Pogulay, S. S.; Terent'yeva, A. G.; Bazhenov, V. Yu; Shchedrin, A. I.; Ryabtsev, A. V.; Kuzmichev, A. I.

    2007-02-01

    In this paper the results of theoretical and experimental studies of the component content of active particles formed in a plasma-chemical reactor composed of a multiple-cell generator of active particles, based on volume barrier discharge, and a working chamber are presented. For calculation of the content of uncharged plasma components an approach is proposed which is based on averaging of the power introduced over the entire volume. Advantages of such an approach lie in an absence of fitting parameters, such as the dimensions of microdischarges, their surface density and rate of breakdown. The calculation and the experiment were accomplished with the use of dry air (20% relative humidity) as the plasma generating medium. Concentrations of O3, HNO3, HNO2, N2 O5 and NO3 were measured experimentally in the discharge volume and working chamber for the residence time of particles on a discharge of 0.3 s and more and discharge specific power of 1.5 W cm-3. It has been determined that the best agreement between the calculation and the experiment occurs at calculated gas medium temperatures in the discharge plasma of about 400-425 K, which correspond to the experimentally measured rotational temperature of nitrogen. In most cases the calculated concentrations of O3, HNO3, HNO2, N2O5 and NO3 for the barrier discharge and the working chamber are in fairly good agreement with the respective measured values.

  18. The component content of active particles in a plasma-chemical reactor based on volume barrier discharge

    International Nuclear Information System (INIS)

    Soloshenko, I A; Tsiolko, V V; Pogulay, S S; Terent'yeva, A G; Bazhenov, V Yu; Shchedrin, A I; Ryabtsev, A V; Kuzmichev, A I

    2007-01-01

    In this paper the results of theoretical and experimental studies of the component content of active particles formed in a plasma-chemical reactor composed of a multiple-cell generator of active particles, based on volume barrier discharge, and a working chamber are presented. For calculation of the content of uncharged plasma components an approach is proposed which is based on averaging of the power introduced over the entire volume. Advantages of such an approach lie in an absence of fitting parameters, such as the dimensions of microdischarges, their surface density and rate of breakdown. The calculation and the experiment were accomplished with the use of dry air (20% relative humidity) as the plasma generating medium. Concentrations of O 3 , HNO 3 , HNO 2 , N 2 O 5 and NO 3 were measured experimentally in the discharge volume and working chamber for the residence time of particles on a discharge of 0.3 s and more and discharge specific power of 1.5 W cm -3 . It has been determined that the best agreement between the calculation and the experiment occurs at calculated gas medium temperatures in the discharge plasma of about 400-425 K, which correspond to the experimentally measured rotational temperature of nitrogen. In most cases the calculated concentrations of O 3 , HNO 3 , HNO 2 , N 2 O 5 and NO 3 for the barrier discharge and the working chamber are in fairly good agreement with the respective measured values

  19. Atmospheric-pressure electric discharge as an instrument of chemical activation of water solutions

    Science.gov (United States)

    Rybkin, V. V.; Shutov, D. A.

    2017-11-01

    Results of experimental studies and numerical simulations of physicochemical characteristics of plasmas generated in different types of atmospheric-pressure discharges (pulsed streamer corona, gliding electric arc, dielectric barrier discharge, glow-discharge electrolysis, diaphragmatic discharge, and dc glow discharge) used to initiate various chemical processes in water solutions are analyzed. Typical reactor designs are considered. Data on the power supply characteristics, plasma electron parameters, gas temperatures, and densities of active particles in different types of discharges excited in different gases and their dependences on the external parameters of discharges are presented. The chemical composition of active particles formed in water is described. Possible mechanisms of production and loss of plasma particles are discussed.

  20. Optimization of the plasma parameters for the high current and uniform large-scale pulse arc ion source of the VEST-NBI system

    International Nuclear Information System (INIS)

    Jung, Bongki; Park, Min; Heo, Sung Ryul; Kim, Tae-Seong; Jeong, Seung Ho; Chang, Doo-Hee; Lee, Kwang Won; In, Sang-Ryul

    2016-01-01

    Highlights: • High power magnetic bucket-type arc plasma source for the VEST NBI system is developed with modifications based on the prototype plasma source for KSTAR. • Plasma parameters in pulse duration are measured to characterize the plasma source. • High plasma density and good uniformity is achieved at the low operating pressure below 1 Pa. • Required ion beam current density is confirmed by analysis of plasma parameters and results of a particle balance model. - Abstract: A large-scale hydrogen arc plasma source was developed at the Korea Atomic Energy Research Institute for a high power pulsed NBI system of VEST which is a compact spherical tokamak at Seoul national university. One of the research target of VEST is to study innovative tokamak operating scenarios. For this purpose, high current density and uniform large-scale pulse plasma source is required to satisfy the target ion beam power efficiently. Therefore, optimizing the plasma parameters of the ion source such as the electron density, temperature, and plasma uniformity is conducted by changing the operating conditions of the plasma source. Furthermore, ion species of the hydrogen plasma source are analyzed using a particle balance model to increase the monatomic fraction which is another essential parameter for increasing the ion beam current density. Conclusively, efficient operating conditions are presented from the results of the optimized plasma parameters and the extractable ion beam current is calculated.

  1. Microwave plasma for materials treatment; Plasmas de microondas para tratamiento de materiales

    Energy Technology Data Exchange (ETDEWEB)

    Camps, E.; Garcia, J.L.; Muhl, S.; Alvarez F, O.; Chavez C, J. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    The microwave discharges of the Electron Cyclotron Resonance (Ecr) type are capable to generate plasma with relatively high ionization coefficients which can vary between 1 and 10 % also they are realized in low pressures at 10 {sup -4} Torr. order generating at this time high concentrations of neutral excited chemical species which result in that the chemical processes can be realized with much greater velocity as in another systems. In this work it was studied and characterized a microwave discharge type Ecr using for this electric probes and optical emission spectroscopy. The characterization was carried out with the purpose of optimizing the plasma parameters and to establish a control over the same one doing so that the experiments have a greater reproducibility and a major work efficiency. (Author)

  2. Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq

    Directory of Open Access Journals (Sweden)

    Al-Marzoki JM

    2012-10-01

    Full Text Available Jasim M Al-Marzoki1, Zainab W Al-Maaroof2, Ali H Kadhum31Department of Pediatrics, 2Department of Pathology, Babylon Medical College, 3Babylon Gynecology and Pediatric Teaching Hospital, Hilla, IraqBackground: The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq.Methods: A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually.Results: Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3 g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6 × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472 × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count.Conclusion: Most results

  3. Effects of boronisation on the plasma parameters in TCA

    International Nuclear Information System (INIS)

    Dudok de Wit, Th.; Duval, B.P.; Hollenstein, Ch.; Joye, B.

    1990-01-01

    Wall conditioning and deposition of low Z materials on the first wall and limiters play an important role in plasma impurity control. Carbon film deposition (carbonisation) is already used on many Tokamaks. As proposed by Veprek, a film containing boron and carbon would be more resistant to chemical erosion and could also getter the oxygen. This procedure (boronisation) has been tried on Textor, Asdex and recently on TCA. The TCA vacuum vessel, the 8 rf antenna groups and 4 antenna screens are stainless steel and there are 4 carbon limiters placed in one poloidal plane. (author) 6 refs., 3 figs

  4. Calculation of gas-flow in plasma reactor for carbon partial oxidation

    Science.gov (United States)

    Bespala, Evgeny; Myshkin, Vyacheslav; Novoselov, Ivan; Pavliuk, Alexander; Makarevich, Semen; Bespala, Yuliya

    2018-03-01

    The paper discusses isotopic effects at carbon oxidation in low temperature non-equilibrium plasma at constant magnetic field. There is described routine of experiment and defined optimal parameters ensuring maximum enrichment factor at given electrophysical, gas-dynamic, and thermodymanical parameters. It has been demonstrated that at high-frequency generator capacity of 4 kW, supply frequency of 27 MHz and field density of 44 mT the concentration of paramagnetic heavy nuclei 13C in gaseous phase increases up to 1.78 % compared to 1.11 % for natural concentration. Authors explain isotopic effect decrease during plasmachemical separation induced by mixing gas flows enriched in different isotopes at the lack of product quench. With the help of modeling the motion of gas flows inside the plasma-chemical reactor based on numerical calculation of Navier-Stokes equation authors determine zones of gas mixing and cooling speed. To increase isotopic effects and proportion of 13C in gaseous phase it has been proposed to use quench in the form of Laval nozzle of refractory steel. The article represents results on calculation of optimal Laval Nozzle parameters for plasma-chemical reactor of chosen geometry of. There are also given dependences of quench time of products on pressure at the diffuser output and on critical section diameter. Authors determine the location of quench inside the plasma-chemical reactor in the paper.

  5. Hydrogen plasma enhanced alignment on CNT-STM tips grown by liquid catalyst-assisted microwave plasma-enhanced chemical vapor deposition

    International Nuclear Information System (INIS)

    Tung, Fa-Kuei; Yoshimura, Masamichi; Ueda, Kazuyuki; Ohira, Yutaka; Tanji, Takayoshi

    2008-01-01

    Carbon nanotubes are grown directly on a scanning tunneling microscopy tip by liquid catalyst-assisted microwave-enhanced chemical vapor deposition, and effects of hydrogen plasma treatment on the tip have been investigated in detail by field-emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM) and Raman spectroscopy. The unaligned CNTs on the as-grown tip apex have been realigned and reshaped by subsequent hydrogen plasma treatment. The diameter of CNTs is enlarged mainly due to amorphous layers being re-sputtered over their outer shells

  6. Simultaneous determination of glucose, triglycerides, urea, cholesterol, albumin and total protein in human plasma by Fourier transform infrared spectroscopy: direct clinical biochemistry without reagents.

    Science.gov (United States)

    Jessen, Torben E; Höskuldsson, Agnar T; Bjerrum, Poul J; Verder, Henrik; Sørensen, Lars; Bratholm, Palle S; Christensen, Bo; Jensen, Lene S; Jensen, Maria A B

    2014-09-01

    Direct measurement of chemical constituents in complex biologic matrices without the use of analyte specific reagents could be a step forward toward the simplification of clinical biochemistry. Problems related to reagents such as production errors, improper handling, and lot-to-lot variations would be eliminated as well as errors occurring during assay execution. We describe and validate a reagent free method for direct measurement of six analytes in human plasma based on Fourier-transform infrared spectroscopy (FTIR). Blood plasma is analyzed without any sample preparation. FTIR spectrum of the raw plasma is recorded in a sampling cuvette specially designed for measurement of aqueous solutions. For each analyte, a mathematical calibration process is performed by a stepwise selection of wavelengths giving the optimal least-squares correlation between the measured FTIR signal and the analyte concentration measured by conventional clinical reference methods. The developed calibration algorithms are subsequently evaluated for their capability to predict the concentration of the six analytes in blinded patient samples. The correlation between the six FTIR methods and corresponding reference methods were 0.87albumin and total protein in human plasma. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Long-time integrator for the study on plasma parameter fluctuations

    International Nuclear Information System (INIS)

    Zalkind, V.M.; Tarasenko, V.P.

    1975-01-01

    A device measuring the absolute value (x) of a fluctuating quantity x(t) averaged over a large number of realizations is described. The specific features of the device are the use of the time selector (Δ t = 50 μs - 1 ms) and the large time integration constant (tau = 30 hrs). The device is meant for studying fluctuations of parameters of a pulse plasma with a small repetition frequency

  8. Computational study of sheath structure in oxygen containing plasmas at medium pressures

    Science.gov (United States)

    Hrach, Rudolf; Novak, Stanislav; Ibehej, Tomas; Hrachova, Vera

    2016-09-01

    Plasma mixtures containing active species are used in many plasma-assisted material treatment technologies. The analysis of such systems is rather difficult, as both physical and chemical processes affect plasma properties. A combination of experimental and computational approaches is the best suited, especially at higher pressures and/or in chemically active plasmas. The first part of our study of argon-oxygen mixtures was based on experimental results obtained in the positive column of DC glow discharge. The plasma was analysed by the macroscopic kinetic approach which is based on the set of chemical reactions in the discharge. The result of this model is a time evolution of the number densities of each species. In the second part of contribution the detailed analysis of processes taking place during the interaction of oxygen containing plasma with immersed substrates was performed, the results of the first model being the input parameters. The used method was the particle simulation technique applied to multicomponent plasma. The sheath structure and fluxes of charged particles to substrates were analysed in the dependence on plasma pressure, plasma composition and surface geometry.

  9. Influence of plasma density on the chemical composition and structural properties of pulsed laser deposited TiAlN thin films

    Energy Technology Data Exchange (ETDEWEB)

    Quiñones-Galván, J. G.; Camps, Enrique [Departamento de Física, Instituto Nacional de Investigaciones Nucleares, Apartado Postal 18-1027, México D.F. C.P. 11801 (Mexico); Muhl, S. [Instituto de Investigaciones en Materiales, UNAM, México D.F. C.P. 04510 (Mexico); Flores, M. [Departamento de Ingeniería de Proyectos, CUCEI, Universidad de Guadalajara, Apdo. Postal 307, C.P. 45101 Zapopan, Jalisco (Mexico); Campos-González, E. [Departamento de Física, CINVESTAV-IPN, Apdo. Postal 14-740, México D.F. 07360 (Mexico)

    2014-05-15

    Incorporation of substitutional Al into the TiN lattice of the ternary alloy TiAlN results in a material with improved properties compared to TiN. In this work, TiAlN thin films were grown by the simultaneous ablation of Ti and Al targets in a nitrogen containing reactive atmosphere. The deposit was formed on silicon substrates at low deposition temperature (200 °C). The dependence of the Al content of the films was studied as a function of the ion density of the plasma produced by the laser ablation of the Al target. The plasma parameters were measured by means of a planar Langmuir probe and optical emission spectroscopy. The chemical composition of the films was measured by energy dispersive X-ray spectroscopy. The results showed a strong dependence of the amount of aluminum incorporated in the films with the plasma density. The structural characterization of the deposits was carried out by Raman spectroscopy, X-ray diffraction, and transmission electron microscopy, where the substitutional incorporation of the Al into the TiN was demonstrated.

  10. Optical and electrical characteristics of plasma enhanced chemical vapor deposition boron carbonitride thin films derived from N-trimethylborazine precursor

    Energy Technology Data Exchange (ETDEWEB)

    Sulyaeva, Veronica S., E-mail: veronica@niic.nsc.ru [Department of Functional Materials Chemistry, Nikolaev Institute of Inorganic Chemistry SB RAS, Novosibirsk 630090 (Russian Federation); Kosinova, Marina L.; Rumyantsev, Yurii M.; Kuznetsov, Fedor A. [Department of Functional Materials Chemistry, Nikolaev Institute of Inorganic Chemistry SB RAS, Novosibirsk 630090 (Russian Federation); Kesler, Valerii G. [Laboratory of Physical Principles for Integrated Microelectronics, Rzhanov Institute of Semiconductor Physics SB RAS, Novosibirsk 630090 (Russian Federation); Kirienko, Viktor V. [Laboratory of Nonequilibrium Semiconductors Systems, Rzhanov Institute of Semiconductor Physics SB RAS, Novosibirsk 630090 (Russian Federation)

    2014-05-02

    Thin BC{sub x}N{sub y} films have been obtained by plasma enhanced chemical vapor deposition using N-trimethylborazine as a precursor. The films were deposited on Si(100) and fused silica substrates. The grown films were characterized by ellipsometry, Fourier transform infrared spectroscopy, scanning electron microscopy, X-ray energy dispersive spectroscopy, X-ray photoelectron spectroscopy, spectrophotometry, capacitance–voltage and current–voltage measurements. The deposition parameters, such as substrate temperature (373–973 K) and gas phase composition were varied. Low temperature BC{sub x}N{sub y} films were found to be high optical transparent layers in the range of 300–2000 nm, the transmittance as high as 93% has been achieved. BC{sub x}N{sub y} layers are dielectrics with dielectric constant k = 2.2–8.9 depending on the synthesis conditions. - Highlights: • Thin BC{sub x}N{sub y} films have been obtained by plasma enhanced chemical vapor deposition. • N-trimethylborazine was used as a precursor. • Low temperature BC{sub x}N{sub y} films were found to be high optical transparent layers (93%). • BC{sub x}N{sub y} layers are dielectrics with dielectric constant k = 2.2–8.9.

  11. Exploring Chemical and Thermal Non-equilibrium in Nitrogen Arcs

    International Nuclear Information System (INIS)

    Ghorui, S; Das, A K

    2012-01-01

    Plasma torches operating with nitrogen are of special importance as they can operate with usual tungsten based refractory electrodes and offer radical rich non-oxidizing high temperature environment for plasma chemistry. Strong gradients in temperature as well as species densities and huge convective fluxes lead to varying degrees of chemical non-equilibrium in associated regions. An axi-symmetric two-temperature chemical non-equilibrium model of a nitrogen plasma torch has been developed to understand the effects of thermal and chemical non-equilibrium in arcs. A 2-D finite volume CFD code in association with a non-equilibrium property routine enabled extraction of steady state self-consistent distributions of various plasma quantities inside the torch under various thermal and chemical non-equilibrium conditions. Chemical non-equilibrium has been incorporated through computation of diffusive and convective fluxes in each finite volume cell in every iteration and associating corresponding thermodynamic and transport properties through the scheme of 'chemical non-equilibrium parameter' introduced by Ghorui et. al. Recombination coefficient data from Nahar et. al. and radiation data from Krey and Morris have been used in the simulation. Results are presented for distributions of temperature, pressure, velocity, current density, electric potential, species densities and chemical non-equilibrium effects. Obtained results are compared with similar results under LTE.

  12. Environmental parameters of the Tennessee River in Alabama. 2: Physical, chemical, and biological parameters. [biological and chemical effects of thermal pollution from nuclear power plants on water quality

    Science.gov (United States)

    Rosing, L. M.

    1976-01-01

    Physical, chemical and biological water quality data from five sites in the Tennessee River, two in Guntersville Reservoir and three in Wheeler Reservoir were correlated with climatological data for three annual cycles. Two of the annual cycles are for the years prior to the Browns Ferry Nuclear Power Plant operations and one is for the first 14 months of Plant operations. A comparison of the results of the annual cycles indicates that two distinct physical conditions in the reservoirs occur, one during the warm months when the reservoirs are at capacity and one during the colder winter months when the reservoirs have been drawn-down for water storage during the rainy months and for weed control. The wide variations of physical and chemical parameters to which the biological organisms are subjected on an annual basis control the biological organisms and their population levels. A comparison of the parameters of the site below the Power plant indicates that the heated effluent from the plant operating with two of the three reactors has not had any effect on the organisms at this site. Recommendations given include the development of prediction mathematical models (statistical analysis) for the physical and chemical parameters under specific climatological conditions which affect biological organisms. Tabulated data of chemical analysis of water and organism populations studied is given.

  13. Correlation of Magnetic Fields with Solar Wind Plasma Parameters at 1AU

    Science.gov (United States)

    Shen, F.

    2017-12-01

    The physical parameters of the solar wind observed in-situ near 1AU have been studied for several decades, and relationships between them, such as the positive correlation between the solar wind plasma temperature T and velocity V, and the negative correlation between density N and velocity V, are well known. However, the magnetic field intensity does not appear to be well correlated with any individual plasma parameter. In this paper, we discuss previously under-reported correlations between B and the combined plasma parameters √NV2 as well as between B and √NT. These two correlations are strong during the periods of corotating interaction regions and high speed streams, moderate during intervals of slow solar wind, and rather poor during the passage of interplanetary coronal mass ejections. The results indicate that the magnetic pressure in the solar wind is well correlated both with the plasma dynamic pressure and the thermal pressure. Then, we employ a 3D MHD model to simulate the formation of the relationships between the magnetic strength B and √NV2 as well as √NT observed at 1AU. The inner boundary condition is derived by empirical models, with the magnetic field and density are optional. Five kinds of boundary conditions at the inner boundary of heliosphere are tested. In the cases that the magnetic field is related to speed at the inner boundary, the correlation coefficients between B and √NV2 as well as between B and √NT are even higher than that in the observational results. At 1AU the simulated radial magnetic field shows little latitude dependence, which matches the observation of Ulysses. Most of the modeled characters in these cases are closer to observation than others. This inner boundary condition may more accurately characterize Sun's magnetic influence on the heliosphere. The new input may be able to improve the simulation of CME propagation in the inner heliosphere and the space weather forecasting.

  14. Lindhard's polarization parameter and atomic sum rules in the local plasma approximation

    DEFF Research Database (Denmark)

    Cabrera-Trujillo, R.; Apell, P.; Oddershede, J.

    2017-01-01

    In this work, we analyze the effects of Lindhard polarization parameter, χ, on the sum rule, Sp, within the local plasma approximation (LPA) as well as on the logarithmic sum rule Lp = dSp/dp, in both cases for the system in an initial excited state. We show results for a hydrogenic atom with nuc......In this work, we analyze the effects of Lindhard polarization parameter, χ, on the sum rule, Sp, within the local plasma approximation (LPA) as well as on the logarithmic sum rule Lp = dSp/dp, in both cases for the system in an initial excited state. We show results for a hydrogenic atom...... in terms of a screened charge Z* for the ground state. Our study shows that by increasing χ, the sum rule for p0 it increases, and the value p=0 provides the normalization/closure relation which remains fixed to the number of electrons for the same initial state. When p is fixed...

  15. Chemical Evolution of Strongly Interacting Quark-Gluon Plasma

    International Nuclear Information System (INIS)

    Pan, Ying-Hua; Zhang, Wei-Ning

    2014-01-01

    At very initial stage of relativistic heavy ion collisions a wave of quark-gluon matter is produced from the break-up of the strong color electric field and then thermalizes at a short time scale (~1 fm/c). However, the quark-gluon plasma (QGP) system is far out of chemical equilibrium, especially for the heavy quarks which are supposed to reach chemical equilibrium much late. In this paper a continuing quark production picture for strongly interacting QGP system is derived, using the quark number susceptibilities and the equation of state; both of them are from the results calculated by the Wuppertal-Budapest lattice QCD collaboration. We find that the densities of light quarks increase by 75% from the temperature T=400 MeV to T=150 MeV, while the density of strange quark annihilates by 18% in the temperature region. We also offer a discussion on how this late production of quarks affects the final charge-charge correlations

  16. Clinical and atopic parameters and airway inflammatory markers in childhood asthma: a factor analysis

    Science.gov (United States)

    Leung, T; Wong, G; Ko, F; Lam, C; Fok, T

    2005-01-01

    Background: Recent studies have repeatedly shown weak correlations among lung function parameters, atopy, exhaled nitric oxide level (FeNO), and airway inflammatory markers, suggesting that they are non-overlapping characteristics of asthma in adults. A study was undertaken to determine, using factor analysis, whether the above features represent separate dimensions of childhood asthma. Methods: Clinically stable asthmatic patients aged 7–18 years underwent spirometric testing, methacholine bronchial challenge, blood sampling for atopy markers and chemokine levels (macrophage derived chemokine (MDC), thymus and activation regulated chemokine (TARC), and eotaxin), FeNO, and chemokines (MDC and eotaxin) and leukotriene B4 measurements in exhaled breath condensate (EBC). Results: The mean (SD) forced expiratory volume in 1 second (FEV1) and FeNO of 92 patients were 92.1 (15.9)% predicted and 87.3 (65.7) ppb, respectively. 59% of patients received inhaled corticosteroids. Factor analysis selected four different factors, explaining 55.5% of total variance. The Kaiser-Meyer-Olkin measure of sampling adequacy was 0.587. Plasma total and specific IgE levels, peripheral blood eosinophil percentage, and FeNO loaded on factor 1; plasma TARC and MDC concentrations on factor 2; MDC, eotaxin and leukotriene B4 concentrations in EBC on factor 3; and plasma eotaxin concentration together with clinical indices including body mass index and disease severity score loaded on factor 4. Post hoc factor analyses revealed similar results when outliers were excluded. Conclusions: The results suggest that atopy related indices and airway inflammation are separate dimensions in the assessment of childhood asthma, and inflammatory markers in peripheral blood and EBC are non-overlapping factors of asthma. PMID:16055623

  17. Comparison of some effects of modification of a polylactide surface layer by chemical, plasma, and laser methods

    Energy Technology Data Exchange (ETDEWEB)

    Moraczewski, Krzysztof, E-mail: kmm@ukw.edu.pl [Department of Materials Engineering, Kazimierz Wielki University, Department of Materials Engineering, ul. Chodkiewicza 30, 85-064 Bydgoszcz (Poland); Rytlewski, Piotr [Department of Materials Engineering, Kazimierz Wielki University, Department of Materials Engineering, ul. Chodkiewicza 30, 85-064 Bydgoszcz (Poland); Malinowski, Rafał [Institute for Engineering of Polymer Materials and Dyes, ul. M. Skłodowskiej–Curie 55, 87-100 Toruń (Poland); Żenkiewicz, Marian [Department of Materials Engineering, Kazimierz Wielki University, Department of Materials Engineering, ul. Chodkiewicza 30, 85-064 Bydgoszcz (Poland)

    2015-08-15

    Highlights: • We modified polylactide surface layer with chemical, plasma or laser methods. • We tested selected properties and surface structure of modified samples. • We stated that the plasma treatment appears to be the most beneficial. - Abstract: The article presents the results of studies and comparison of selected properties of the modified PLA surface layer. The modification was carried out with three methods. In the chemical method, a 0.25 M solution of sodium hydroxide in water and ethanol was utilized. In the plasma method, a 50 W generator was used, which produced plasma in the air atmosphere under reduced pressure. In the laser method, a pulsed ArF excimer laser with fluency of 60 mJ/cm{sup 2} was applied. Polylactide samples were examined by using the following techniques: scanning electron microscopy (SEM), atomic force microscopy (AFM), goniometry and X-ray photoelectron spectroscopy (XPS). Images of surfaces of the modified samples were recorded, contact angles were measured, and surface free energy was calculated. Qualitative and quantitative analyses of chemical composition of the PLA surface layer were performed as well. Based on the survey it was found that the best modification results are obtained using the plasma method.

  18. Effect of transient scrotal hyperthermia on sperm parameters, seminal plasma biochemical markers, and oxidative stress in men

    Directory of Open Access Journals (Sweden)

    Meng Rao

    2015-01-01

    Full Text Available In this experimental prospective study, we aimed to analyze the effect of transient scrotal hyperthermia on the male reproductive organs, from the perspective of sperm parameters, semen plasma biochemical markers, and oxidative stress, to evaluate whether different frequencies of heat exposure cause different degrees of damage to spermatogenesis. Two groups of volunteers (10 per group received testicular warming in a 43°C water bath 10 times, for 30 min each time: group 1: 10 consecutive days; group 2: once every 3 days. Sperm parameters, epididymis and accessory sex gland function, semen plasma oxidative stress and serum sex hormones were tested before treatment and in the 16-week recovery period after treatment. At last, we found an obvious reversible decrease in sperm concentration (P = 0.005 for Group 1 and P= 0.008 for Group 2 when the minimums were compared with baseline levels, the same below, motility (P = 0.009 and 0.021, respectively, the hypoosmotic swelling test score (P = 0.007 and 0.008, respectively, total acrosin activity (P = 0.018 and 0.009, respectively, and an increase in the seminal plasma malondialdehyde concentration (P = 0.005 and 0.017, respectively. The decrease of sperm concentration was greater for Group 2 than for Group 1 (P = 0.031. We concluded that transient scrotal hyperthermia seriously, but reversibly, negatively affected the spermatogenesis, oxidative stress may be involved in this process. In addition, intermittent heat exposure more seriously suppresses the spermatogenesis compared to consecutive heat exposure. This may be indicative for clinical infertility etiology analysis and the design of contraceptive methods based on heat stress.

  19. Measurement of plasma parameters

    International Nuclear Information System (INIS)

    1999-01-01

    The physics issues of the measurements of the plasma properties necessary to provide both the control and science data for achieving the goals of the ITER device are discussed. The assessment of the requirements for these measurements is first discussed, together with priorities that relate to the experimental program. Subsequently, some of the proposed measurement techniques, the plasma diagnostics, are described with particular emphasis on their implementation on ITER and their capability to meet the requirements. A judgement on the present status of the diagnostic program on ITER is provided with some indication of the research and development program necessary to demonstrate viability of techniques or their implementation. (author)

  20. The LXCat project: Electron scattering cross sections and swarm parameters for low temperature plasma modeling

    International Nuclear Information System (INIS)

    Pancheshnyi, S.; Biagi, S.; Bordage, M.C.; Hagelaar, G.J.M.; Morgan, W.L.; Phelps, A.V.; Pitchford, L.C.

    2012-01-01

    Graphical abstract: LXCat is an open-access website containing data needed for low temperature plasma modeling as well as on-line tools useful for their manipulation. Highlights: ► LXCat: an open-access website with data for low temperature plasma modeling. ► Contains compilations of electron scattering cross sections and transport data. ► Data from different contributors for many neutral, ground-state species. ► On-line tools for browsing, plotting, up/downloading data. ► On-line Boltzmann solver for calculating electron swarm parameters. - Abstract: LXCat is a dynamic, open-access, website for collecting, displaying, and downloading ELECtron SCATtering cross sections and swarm parameters (mobility, diffusion coefficient, reaction rates, etc.) required for modeling low temperature, non-equilibrium plasmas. Contributors set up individual databases, and the available databases, indicated by the contributor’s chosen title, include mainly complete sets of electron-neutral scattering cross sections, although the option for introducing partial sets of cross sections exists. A database for measured swarm parameters is also part of LXCat, and this is a growing activity. On-line tools include options for browsing, plotting, and downloading cross section data. The electron energy distribution functions (edfs) in low temperature plasmas are in general non-Maxwellian, and LXCat provides an option for execution of an on-line Boltzmann equation solver to calculate the edf in homogeneous electric fields. Thus, the user can obtain electron transport and rate coefficients (averages over the edfs) in pure gases or gas mixtures over a range of values of the reduced electric fields strength, E/N, the ratio of the electric field strength to the neutral density, using cross sections from the available databases. New contributors are welcome and anyone wishing to create a database and upload data can request a username and password. LXCat is part of a larger, community

  1. Chemically reactive species in liquids generated by atmospheric-pressure plasmas and their roles in plasma medicine

    International Nuclear Information System (INIS)

    Hamaguchi, Satoshi

    2013-01-01

    Plasmas whose gas temperatures are close to room temperature may be generated in ambient air or a gas at atmospheric pressure with the use of low-frequency high voltage or low-power radio-frequency (RF) or microwave power applied to electrodes. Such plasmas can serve as a powerful source of free radicals and/or chemically reactive species that arise from atoms and molecules of the ambient gas. Recently use of such plasmas for medical purposes has attracted much attention as they can be implemented in possible medical devices that can cause blood coagulation, heal wounds, facilitate angiogenesis, sterilize surgical devices as well as living tissues without harming healthy cells, and selectively inactivate cancer cells. Especially of interest among reactive species generated by atmospheric-pressure plasmas (APP) are reactive oxygen species (ROS) and reactive nitrogen species (RNS) that are generated in liquid phase. Since most living tissues and cells are immersed in liquids (such as blood or culture media), reactive species generated by APPs in the gas phase are transported to the liquid phase and possibly converted to different types of reactive species therein before causing some influence on the tissues or cells. In this study, the rate equations are solved to evaluate concentrations of various reactive species in pure water that are originated by plasma reactions in atmosphere and possible effects of such species (including ROS/RNS) on living tissues and cells are discussed

  2. Chemically reactive species in liquids generated by atmospheric-pressure plasmas and their roles in plasma medicine

    Energy Technology Data Exchange (ETDEWEB)

    Hamaguchi, Satoshi [Center for Atomic and Molecular Technologies, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2013-07-11

    Plasmas whose gas temperatures are close to room temperature may be generated in ambient air or a gas at atmospheric pressure with the use of low-frequency high voltage or low-power radio-frequency (RF) or microwave power applied to electrodes. Such plasmas can serve as a powerful source of free radicals and/or chemically reactive species that arise from atoms and molecules of the ambient gas. Recently use of such plasmas for medical purposes has attracted much attention as they can be implemented in possible medical devices that can cause blood coagulation, heal wounds, facilitate angiogenesis, sterilize surgical devices as well as living tissues without harming healthy cells, and selectively inactivate cancer cells. Especially of interest among reactive species generated by atmospheric-pressure plasmas (APP) are reactive oxygen species (ROS) and reactive nitrogen species (RNS) that are generated in liquid phase. Since most living tissues and cells are immersed in liquids (such as blood or culture media), reactive species generated by APPs in the gas phase are transported to the liquid phase and possibly converted to different types of reactive species therein before causing some influence on the tissues or cells. In this study, the rate equations are solved to evaluate concentrations of various reactive species in pure water that are originated by plasma reactions in atmosphere and possible effects of such species (including ROS/RNS) on living tissues and cells are discussed.

  3. Microdose clinical trial: quantitative determination of nicardipine and prediction of metabolites in human plasma.

    Science.gov (United States)

    Yamane, Naoe; Takami, Tomonori; Tozuka, Zenzaburo; Sugiyama, Yuichi; Yamazaki, Akira; Kumagai, Yuji

    2009-01-01

    A sample treatment procedure and high-sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for quantitative determination of nicardipine in human plasma were developed for a microdose clinical trial with nicardipine, a non-radioisotope labeled drug. The calibration curve was linear in the range of 1-500 pg/mL using 1 mL of plasma. Analytical method validation for the clinical dose, for which the calibration curve was linear in the range of 0.2-100 ng/mL using 20 microL of plasma, was also conducted. Each method was successfully applied to making determinations in plasma using LC/MS/MS after administration of a microdose (100 microg) and clinical dose (20 mg) to each of six healthy volunteers. We tested new approaches in the search for metabolites in plasma after microdosing. In vitro metabolites of nicardipine were characterized using linear ion trap-fourier transform ion cyclotron resonance mass spectrometry (LIT-FTICRMS) and the nine metabolites predicted to be in plasma were analyzed using LC/MS/MS. There is a strong possibility that analysis of metabolites by LC/MS/MS may advance to utilization in microdose clinical trials with non-radioisotope labeled drugs.

  4. Plasma metabolic profiling of dairy cows affected with clinical ketosis using LC/MS technology.

    Science.gov (United States)

    Li, Y; Xu, C; Xia, C; Zhang, Hy; Sun, Lw; Gao, Y

    2014-01-01

    Ketosis in dairy cattle is an important metabolic disorder. Currently, the plasma metabolic profile of ketosis as determined using liquid chromatography-mass spectrometry (LC/MS) has not been reported. To investigate plasma metabolic profiles from cows with clinical ketosis in comparison to control cows. Twenty Holstein dairy cows were divided into two groups based on clinical signs and plasma β-hydroxybutyric acid and glucose concentrations 7-21 days postpartum: clinical ketosis and control cows. Plasma metabolic profiles were analyzed using LC/MS. Data were processed using principal component analysis and orthogonal partial least-squares discriminant analysis. Compared to control cows, the levels of valine, glycine, glycocholic, tetradecenoic acid, and palmitoleic acid increased significantly in clinical ketosis. On the other hand, the levels of arginine, aminobutyric acid, leucine/isoleucine, tryptophan, creatinine, lysine, norcotinine, and undecanoic acid decreased markedly. Our results showed that the metabolic changes in cows with clinical ketosis involve complex metabolic networks and signal transduction. These results are important for future studies elucidating the pathogenesis, diagnosis, and prevention of clinical ketosis in dairy cows.

  5. Assay reproducibility in clinical studies of plasma miRNA.

    Directory of Open Access Journals (Sweden)

    Jonathan Rice

    Full Text Available There are increasing reports of plasma miRNAs as biomarkers of human disease but few standards in methodologic reporting, leading to inconsistent data. We systematically reviewed plasma miRNA studies published between July 2013-June 2014 to assess methodology. Six parameters were investigated: time to plasma extraction, methods of RNA extraction, type of miRNA, quantification, cycle threshold (Ct setting, and methods of statistical analysis. We compared these data with a proposed standard methodologic technique. Beginning with initial screening for 380 miRNAs using microfluidic array technology and validation in an additional cohort of patients, we compared 11 miRNAs that exhibited differential expression between 16 patients with benign colorectal neoplasms (advanced adenomas and 16 patients without any neoplasm (controls. Plasma was isolated immediately, 12, 24, 48, or 72 h following phlebotomy. miRNA was extracted using two different techniques (Trizol LS with pre-amplification or modified miRNeasy. We performed Taqman-based RT-PCR assays for the 11 miRNAs with subsequent analyses using a variable Ct setting or a fixed Ct set at 0.01, 0.03, 0.05, or 0.5. Assays were performed in duplicate by two different operators. RNU6 was the internal reference. Systematic review yielded 74 manuscripts meeting inclusion criteria. One manuscript (1.4% documented all 6 methodological parameters, while < 5% of studies listed Ct setting. In our proposed standard technique, plasma extraction ≤12 h provided consistent ΔCt. miRNeasy extraction yielded higher miRNA concentrations and fewer non-expressed miRNAs compared to Trizol LS (1/704 miRNAs [0.14%] vs 109/704 miRNAs [15%], not expressed, respectively. A fixed Ct bar setting of 0.03 yielded the most reproducible data, provided that <10% miRNA were non-expressed. There was no significant intra-operator variability. There was significant inter-operator variation using Trizol LS extraction, while this was

  6. The Plasma Parameters and Geometry of Cool and Warm Active Region Loops

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Haixia; Li, Bo; Huang, Zhenghua; Xia, Lidong; Fu, Hui; Mou, Chaozhou [Shandong Provincial Key Laboratory of Optical Astronomy and Solar-Terrestrial Environment, Institute of Space Sciences, Shandong University, Weihai, 264209 Shandong (China); Madjarska, Maria S.; Wiegelmann, Thomas [Max Planck Institute for Solar System Research, Justus-von-Liebig-Weg 3, D-37077, Göttingen (Germany)

    2017-06-10

    How the solar corona is heated to high temperatures remains an unsolved mystery in solar physics. In the present study we analyze observations of 50 whole active region loops taken with the Extreme-ultraviolet Imaging Spectrometer on board the Hinode satellite. Eleven loops were classified as cool loops (<1 MK) and 39 as warm loops (1–2 MK). We study their plasma parameters, such as densities, temperatures, filling factors, nonthermal velocities, and Doppler velocities. We combine spectroscopic analysis with linear force-free magnetic field extrapolation to derive the 3D structure and positioning of the loops, their lengths and heights, and the magnetic field strength along the loops. We use density-sensitive line pairs from Fe xii, Fe xiii, Si x, and Mg vii ions to obtain electron densities by taking special care of intensity background subtraction. The emission measure loci method is used to obtain the loop temperatures. We find that the loops are nearly isothermal along the line of sight. Their filling factors are between 8% and 89%. We also compare the observed parameters with the theoretical Rosner–Tucker–Vaiana (RTV) scaling law. We find that most of the loops are in an overpressure state relative to the RTV predictions. In a follow-up study, we will report a heating model of a parallel-cascade-based mechanism and will compare the model parameters with the loop plasma and structural parameters derived here.

  7. Stationary neoclassical profiles of plasma parameters in stellarators

    International Nuclear Information System (INIS)

    Danilkin, I.S.; Mineev, A.B.

    1991-01-01

    The properties of the neoclassical model of heat and particle transport are considered in connection with calculations of stationary profiles of the plasma parameters in stellarators. The most important feature is the poor agreement with real physical conditions of the boundary, which imposes the necessity of invoking either an additional anomalous transport or a special (although technically possible) consistency between the particle and heat sources in order to obtain a solution in the form of a correct monotonically decreasing profile. In search for monotonic stationary profiles maintained by external sources, it is ascertained that the neoclassical theory does not give rise to the well-known multivalued solutions for the ambipolar electric field

  8. Prediction Of pKa From Chemical Structure Using Free And Open-Source Tools

    Science.gov (United States)

    The ionization state of a chemical, reflected in pKa values, affects lipophilicity, solubility, protein binding and the ability of a chemical to cross the plasma membrane. These properties govern the pharmacokinetic parameters such as absorption, distribution, metabolism, excreti...

  9. Platelet Rich Plasma- mechanism of action and clinical applications

    Directory of Open Access Journals (Sweden)

    Cristina N. Cozma

    2016-11-01

    Full Text Available Platelet-rich plasma (PRP is a blood-derived fraction containing high level of platelets, a high concentration of leukocytes and growth factors. PRP therapy has been growing as a viable treatment alternative for a number of clinical applications and has a potential benefit for use in wound healing. Nowadays platelet rich plasma is used in stimulating wound healing in skin and soft tissue ulcerations, accelerating wound healing in diabetic patients and facilitating bone proliferation in orthopedic and trauma surgery. It has also applications in maxillofacial surgery, spinal surgery, plastic and esthetic surgery, heart surgery and burns. This review of the literature shows a limited number of studies realized on humans that sustain PRP applications in orthopedic and plastic surgery. As the use of PRP increases, more properly structured clinical studies are necessary to confirm the results and to establish clearly the techniques of preparing, the conditions and the clinical indications of applying this therapy.

  10. Jets in a strongly coupled anisotropic plasma

    Energy Technology Data Exchange (ETDEWEB)

    Fadafan, Kazem Bitaghsir [Shahrood University of Technology, Faculty of Physics, Shahrood (Iran, Islamic Republic of); University of Southampton, STAG Research Centre Physics and Astronomy, Southampton (United Kingdom); Morad, Razieh [University of Cape Town, Department of Physics, Rondebosch (South Africa)

    2018-01-15

    In this paper, we study the dynamics of the light quark jet moving through the static, strongly coupled N = 4, anisotropic plasma with and without charge. The light quark is presented by a 2-parameters point-like initial condition falling string in the context of the AdS/CFT. We calculate the stopping distance of the light quark in the anisotropic medium and compare it with its isotropic value. We study the dependency of the stopping distance to the both string initial conditions and background parameters such as anisotropy parameter or chemical potential. Although the typical behavior of the string in the anisotropic medium is similar to the one in the isotropic AdS-Sch background, the string falls faster to the horizon depending on the direction of moving. Particularly, the enhancement of quenching is larger in the beam direction. We find that the suppression of stopping distance is more prominent when the anisotropic plasma have the same temperature as the isotropic plasma. (orig.)

  11. The Diagnosis of Plasma Parameters in Surface Alloying Technique by Optical Emission Spectrometry

    International Nuclear Information System (INIS)

    Fu Yabo; Zhang Yuefei; Chen Qiang; Zhang Guangqiu; Gao Yuan; Wang Jianzhong; Kui Xiaoyun

    2006-01-01

    Electron density (Ne) in a glow discharge plasma for the surface alloying technique is diagnosed by optical emission spectrometry (OES). With CH 4 as the feeding gas, Ne is obtained by comparing the Hβ spectrum according to the Stark broadening effect. It is noticed that Ne varies with the working pressures (30 Pa to 70 Pa) and cathode voltages (500 V to 1000 V), respectively. Due to an abnormal glow discharge, Ne is between 1.71x10 15 /cm 3 to 6.64x10 15 /cm 3 and increases rapidly with working gas pressures and cathode voltages. The results show that OES is a useful method to measure the plasma parameters in a surface alloying glow discharge plasma

  12. Platelet Rich Plasma- mechanism of action and clinical applications

    OpenAIRE

    Cristina N. Cozma; Laura Raducu; Cristian R. Jecan

    2016-01-01

    Platelet-rich plasma (PRP) is a blood-derived fraction containing high level of platelets, a high concentration of leukocytes and growth factors. PRP therapy has been growing as a viable treatment alternative for a number of clinical applications and has a potential benefit for use in wound healing. Nowadays platelet rich plasma is used in stimulating wound healing in skin and soft tissue ulcerations, accelerating wound healing in diabetic patients and facilitating bone proliferation in ortho...

  13. Observation of non-chemical equilibrium effect on Ar-CO2-H2 thermal plasma model by changing pressure

    International Nuclear Information System (INIS)

    Al-Mamun, Sharif Abdullah; Tanaka, Yasunori; Uesugi, Yoshihiko

    2009-01-01

    The authors developed a two-dimensional one-temperature chemical non-equilibrium (1T-NCE) model of Ar-CO 2 -H 2 inductively coupled thermal plasmas (ICTP) to investigate the effect of pressure variation. The basic concept of one-temperature model is the assumption and treatment of the same energy conservation equation for electrons and heavy particles. The energy conservation equations consider reaction heat effects and energy transfer among the species produced as well as enthalpy flow resulting from diffusion. Assuming twenty two (22) different particles in this model and by solving mass conservation equations for each particle, considering diffusion, convection and net production terms resulting from hundred and ninety eight (198) chemical reactions, chemical non-equilibrium effects were taken into account. Transport and thermodynamic properties of Ar-CO 2 -H 2 thermal plasmas were self-consistently calculated using the first-order approximation of the Chapman-Enskog method. Finally results obtained at atmospheric pressure (760 Torr) and at reduced pressure (500, 300 Torr) were compared with results from one-temperature chemical equilibrium (1T-CE) model. And of course, this comparison supported discussion of chemical non-equilibrium effects in the inductively coupled thermal plasmas (ICTP).

  14. Plasma-enhanced chemical vapor deposition of graphene on copper substrates

    Directory of Open Access Journals (Sweden)

    Nicolas Woehrl

    2014-04-01

    Full Text Available A plasma enhanced vapor deposition process is used to synthesize graphene from a hydrogen/methane gas mixture on copper samples. The graphene samples were transferred onto SiO2 substrates and characterized by Raman spectroscopic mapping and atomic force microscope topographical mapping. Analysis of the Raman bands shows that the deposited graphene is clearly SLG and that the sheets are deposited on large areas of several mm2. The defect density in the graphene sheets is calculated using Raman measurements and the influence of the process pressure on the defect density is measured. Furthermore the origin of these defects is discussed with respect to the process parameters and hence the plasma environment.

  15. The constitutive distributed parameter model of multicomponent chemical processes in gas, fluid and solid phase

    International Nuclear Information System (INIS)

    Niemiec, W.

    1985-01-01

    In the literature of distributed parameter modelling of real processes is not considered the class of multicomponent chemical processes in gas, fluid and solid phase. The aim of paper is constitutive distributed parameter physicochemical model, constructed on kinetics and phenomenal analysis of multicomponent chemical processes in gas, fluid and solid phase. The mass, energy and momentum aspects of these multicomponent chemical reactions and adequate phenomena are utilized in balance operations, by conditions of: constitutive invariance for continuous media with space and time memories, reciprocity principle for isotropic and anisotropic nonhomogeneous media with space and time memories, application of definitions of following derivative and equation of continuity, to the construction of systems of partial differential constitutive state equations, in the following derivative forms for gas, fluid and solid phase. Couched in this way all physicochemical conditions of multicomponent chemical processes in gas, fluid and solid phase are new form of constitutive distributed parameter model for automatics and its systems of equations are new form of systems of partial differential constitutive state equations in sense of phenomenal distributed parameter control

  16. Inactivation of Escherichia coli on blueberries using cold plasma with chemical augmentation inside a partial vacuum

    Science.gov (United States)

    Justification: The mechanism by which cold plasma inactivates pathogens is through the production of free reactive chemical species. Unfortunately, the most reactive chemical species have the shortest half-life. In a vacuum their half-life is believed to be prolonged. Additionally, these reactive sp...

  17. Effect of basic physical parameters to control plasma meniscus and beam halo formation in negative ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan); Okuda, S.; Nishioka, S.; Hatayama, A. [Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan)

    2013-09-14

    Our previous study shows that the curvature of the plasma meniscus causes the beam halo in the negative ion sources: the negative ions extracted from the periphery of the meniscus are over-focused in the extractor due to the electrostatic lens effect, and consequently become the beam halo. In this article, the detail physics of the plasma meniscus and beam halo formation is investigated with two-dimensional particle-in-cell simulation. It is shown that the basic physical parameters such as the H{sup −} extraction voltage and the effective electron confinement time significantly affect the formation of the plasma meniscus and the resultant beam halo since the penetration of electric field for negative ion extraction depends on these physical parameters. Especially, the electron confinement time depends on the characteristic time of electron escape along the magnetic field as well as the characteristic time of electron diffusion across the magnetic field. The plasma meniscus penetrates deeply into the source plasma region when the effective electron confinement time is short. In this case, the curvature of the plasma meniscus becomes large, and consequently the fraction of the beam halo increases.

  18. Effect of basic physical parameters to control plasma meniscus and beam halo formation in negative ion sources

    International Nuclear Information System (INIS)

    Miyamoto, K.; Okuda, S.; Nishioka, S.; Hatayama, A.

    2013-01-01

    Our previous study shows that the curvature of the plasma meniscus causes the beam halo in the negative ion sources: the negative ions extracted from the periphery of the meniscus are over-focused in the extractor due to the electrostatic lens effect, and consequently become the beam halo. In this article, the detail physics of the plasma meniscus and beam halo formation is investigated with two-dimensional particle-in-cell simulation. It is shown that the basic physical parameters such as the H − extraction voltage and the effective electron confinement time significantly affect the formation of the plasma meniscus and the resultant beam halo since the penetration of electric field for negative ion extraction depends on these physical parameters. Especially, the electron confinement time depends on the characteristic time of electron escape along the magnetic field as well as the characteristic time of electron diffusion across the magnetic field. The plasma meniscus penetrates deeply into the source plasma region when the effective electron confinement time is short. In this case, the curvature of the plasma meniscus becomes large, and consequently the fraction of the beam halo increases

  19. Correlation of III/V semiconductor etch results with physical parameters of high-density reactive plasmas excited by electron cyclotron resonance

    Science.gov (United States)

    Gerhard, FRANZ; Ralf, MEYER; Markus-Christian, AMANN

    2017-12-01

    Reactive ion etching is the interaction of reactive plasmas with surfaces. To obtain a detailed understanding of this process, significant properties of reactive composite low-pressure plasmas driven by electron cyclotron resonance (ECR) were investigated and compared with the radial uniformity of the etch rate. The determination of the electronic properties of chlorine- and hydrogen-containing plasmas enabled the understanding of the pressure-dependent behavior of the plasma density and provided better insights into the electronic parameters of reactive etch gases. From the electrical evaluation of I(V) characteristics obtained using a Langmuir probe, plasmas of different compositions were investigated. The standard method of Druyvesteyn to derive the electron energy distribution functions by the second derivative of the I(V) characteristics was replaced by a mathematical model which has been evolved to be more robust against noise, mainly, because the first derivative of the I(V) characteristics is used. Special attention was given to the power of the energy dependence in the exponent. In particular, for plasmas that are generated by ECR with EM modes, the existence of Maxwellian distribution functions is not to be taken as a self-evident fact, but the bi-Maxwellian distribution was proven for Ar- and Kr-stabilized plasmas. In addition to the electron temperature, the global uniform discharge model has been shown to be useful for calculating the neutral gas temperature. To what extent the invasive method of using a Langmuir probe could be replaced with the non-invasive optical method of emission spectroscopy, particularly actinometry, was investigated, and the resulting data exhibited the same relative behavior as the Langmuir data. The correlation with etchrate data reveals the large chemical part of the removal process—most striking when the data is compared with etching in pure argon. Although the relative amount of the radial variation of plasma density and

  20. Room-temperature plasma-enhanced chemical vapor deposition of SiOCH films using tetraethoxysilane

    International Nuclear Information System (INIS)

    Yamaoka, K.; Yoshizako, Y.; Kato, H.; Tsukiyama, D.; Terai, Y.; Fujiwara, Y.

    2006-01-01

    Carbon-doped silicon oxide (SiOCH) thin films were deposited by room-temperature plasma-enhanced chemical vapor deposition (PECVD) using tetraethoxysilane (TEOS). The deposition rate and composition of the films strongly depended on radio frequency (RF) power. The films deposited at low RF power contained more CH n groups. The SiOCH films showed high etch rate and low refractive index in proportion to the carbon composition. The deposition with low plasma density and low substrate temperature is effective for SiOCH growth by PECVD using TEOS

  1. Penentuan Efektifitas Oksitetrasiklin Melalui Parameter Farmakokinetik/farmakodinamik pada Plasma dan Jaringan Ayam Broiler

    Directory of Open Access Journals (Sweden)

    Agustina Dwi Wijayanti

    2010-06-01

    Full Text Available A study was conducted to determine the effectiveness of oxytetracycline on the basis of itspharmacokinetic/pharmacodynamic (PK/PD parameters in the plasma and tissues of broiler following a50 mg/kg single dose of intravenous administration. The male broiler were injected with oxytetracycline attarsal medial venous. The blood, liver, kidney and abdominal muscle were collected at 14 points of timesamplings. Blood was centrifuged to obtain plasma and all tissues were extracted with Mc Ilvine buffer.Drug concentration in samples was determined by High Performance Liquid Chromatography (HPLCusing AOAC standard reference for tetracycline. The pharmacokinetic parameters of oxytetracycline werecalculated using non compartment method. The results were as follows. For plasma: the AUC was 790,615,5 ?g/mL minute , Clearance was 63,242 mL/min/kg bb, Tmax/Cmax was 1 minute/0,7 ?g/mL, T1/2elimination was 6,4, hours, Vd was 37 L/kg. For liver ; AUC was 36418,89, minute , Tmax/Cmax was 16hours/17,15 ?g/g, and T1/2 elimination was 24,5, hours. For kidney; AUC6808,41 ?g/g minute , Tmax/Cmax 1 minute/16,73 ?g/g, , T1/2 elimination was 11,55 hours. For muscle; AUC was 3502 ?g/g minute,Tmax/Cmax was 1 minute/2,58 ?g/g, T1/2 elimination was 167,39 hours. The ratio of AUC/MIC inplasma and tissues appeared to a good pharmacokinetic/pharmacodynamic parameter to determine theeffectiveness of oxytetracycline.

  2. Determination by R/A of plasma cortisol levels as a parameter of adrenocortical function before and after radiotherapy of gynaecological genital carcinoma

    International Nuclear Information System (INIS)

    Freischem, C.W.

    1980-01-01

    rn 20 female patients with carcinoma of the genitals, day profiles of cortisol were established and ACTH stimulation tests carried out directly after radiotherapy and 6 months later. Plasma concentrations of cortisol were determined in a RIA as parameters of the adrenocortical function. The assumption of a change in adrenocortical activity after radiotherapy of gynaecological genital carcinoma could not be validated. Instead, there was a typical diurnal rhythm of plasma cortisol, with a peak in the early morning hours and a decrease until midnight. The same applies to the ACTH stimulation tests: In all cases, plasma cortisol levels were elevated after intravenous application of ACTH. This means that the 1976 findings of Samundzham and Butsan could not be proved. Since adrenal functions were absolutely normal in the observed cases, the adynamic clinical picture of patients after radiotherapy, which is rather infrequent, cannot be explained as being due to an impaired adrenocortical function. (orig./MG) [de

  3. Informing the Human Plasma Protein Binding of Environmental Chemicals by Machine Learning in the Pharmaceutical Space: Applicability Domain and Limits of Predictability

    Science.gov (United States)

    The free fraction of a xenobiotic in plasma (Fub) is an important determinant of chemical adsorption, distribution, metabolism, elimination, and toxicity, yet experimental plasma protein binding data is scarce for environmentally relevant chemicals. The presented work explores th...

  4. Influence of the plasma pedestal parameters on ELM mitigation at low collisionality

    Energy Technology Data Exchange (ETDEWEB)

    Leuthold, Nils [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany); Universitaet Bayreuth, Universitaetsstrasse 30, 95440 Bayreuth (Germany); Suttrop, Wolfgang [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany)

    2016-07-01

    The control of Edge Localized Modes (ELMs) is of great importance for future fusion devices in order to provide longevity of the plasma facing components and a better overall plasma performance. In recent magnetic perturbation ELM mitigation experiments in ASDEX Upgrade at low pedestal collisionality, the dependence of ELM losses on pedestal parameters is investigated. It is found that the reduction of the stored energy loss associated with ELMs occurs in correlation with a reduction of edge density and edge pedestal pressure induced by the applied magnetic perturbation (''pedestal pump-out''). Significant ELM mitigation occurs at lowest densities, in a region of pedestal n-T parameter space that has not been accessible in ASDEX Upgrade without magnetic perturbations, and which is occupied by type-IV ELMs in DIII-D. The role of magnetic perturbations for ELM mitigation will be discussed in this context and attempts to counteract the confinement loss by increasing neutral beam injection power or pellet injection increases the ELM energy losses.

  5. Nitrogen-doped graphene by microwave plasma chemical vapor deposition

    International Nuclear Information System (INIS)

    Kumar, A.; Voevodin, A.A.; Paul, R.; Altfeder, I.; Zemlyanov, D.; Zakharov, D.N.; Fisher, T.S.

    2013-01-01

    Rapid synthesis of nitrogen-doped, few-layer graphene films on Cu foil is achieved by microwave plasma chemical vapor deposition. The films are doped during synthesis by introduction of nitrogen gas in the reactor. Raman spectroscopy, X-ray photoelectron spectroscopy, transmission electron microscopy and scanning tunneling microscopy reveal crystal structure and chemical characteristics. Nitrogen concentrations up to 2 at.% are observed, and the limit is linked to the rigidity of graphene films on copper surfaces that impedes further nitrogen substitutions of carbon atoms. The entire growth process requires only a few minutes without supplemental substrate heating and offers a promising path toward large-scale synthesis of nitrogen-doped graphene films. - Highlights: ► Rapid synthesis of nitrogen doped few layer graphene on Cu foil. ► Defect density increment on 2% nitrogen doping. ► Nitrogen doped graphene is a good protection to the copper metallic surface

  6. Nitrogen-doped graphene by microwave plasma chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, A., E-mail: kumar50@purdue.edu [Birck Nanotechnolgy Center, Purdue University, West Lafayette, IN 47907 (United States); Voevodin, A.A. [Birck Nanotechnolgy Center, Purdue University, West Lafayette, IN 47907 (United States); Materials and Manufacturing Directorate, Air Force Research Laboratory, WPAFB, OH 45433 (United States); Paul, R. [Birck Nanotechnolgy Center, Purdue University, West Lafayette, IN 47907 (United States); Altfeder, I. [Materials and Manufacturing Directorate, Air Force Research Laboratory, WPAFB, OH 45433 (United States); Zemlyanov, D.; Zakharov, D.N. [Birck Nanotechnolgy Center, Purdue University, West Lafayette, IN 47907 (United States); Fisher, T.S., E-mail: tsfisher@purdue.edu [Birck Nanotechnolgy Center, Purdue University, West Lafayette, IN 47907 (United States); Materials and Manufacturing Directorate, Air Force Research Laboratory, WPAFB, OH 45433 (United States)

    2013-01-01

    Rapid synthesis of nitrogen-doped, few-layer graphene films on Cu foil is achieved by microwave plasma chemical vapor deposition. The films are doped during synthesis by introduction of nitrogen gas in the reactor. Raman spectroscopy, X-ray photoelectron spectroscopy, transmission electron microscopy and scanning tunneling microscopy reveal crystal structure and chemical characteristics. Nitrogen concentrations up to 2 at.% are observed, and the limit is linked to the rigidity of graphene films on copper surfaces that impedes further nitrogen substitutions of carbon atoms. The entire growth process requires only a few minutes without supplemental substrate heating and offers a promising path toward large-scale synthesis of nitrogen-doped graphene films. - Highlights: ► Rapid synthesis of nitrogen doped few layer graphene on Cu foil. ► Defect density increment on 2% nitrogen doping. ► Nitrogen doped graphene is a good protection to the copper metallic surface.

  7. Properties and parameters of the electron beam injected into the mirror magnetic trap of a plasma accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, V. V., E-mail: temple18@mail.ru; Novitsky, A. A.; Vinnichenko, L. A.; Umnov, A. M.; Ndong, D. O. [Peoples’ Friendship University of Russia (Russian Federation)

    2016-03-15

    The parameters of the injector of an axial plasma beam injected into a plasma accelerator operating on the basis of gyroresonance acceleration of electrons in the reverse magnetic field are determined. The trapping of the beam electrons into the regime of gyroresonance acceleration is numerically simulated by the particle- in-cell method. The optimal time of axial injection of the beam into a magnetic mirror trap is determined. The beam parameters satisfying the condition of efficient particle trapping into the gyromagnetic autoresonance regime are found.

  8. Study on stability of a-SiCOF films deposited by plasma enhanced chemical vapor deposition

    International Nuclear Information System (INIS)

    Ding Shijin; Zhang Qingquan; Wang Pengfei; Zhang Wei; Wang Jitao

    2001-01-01

    Low-dielectric-constant a-SiCOF films have been prepared from TEOS, C 4 F 8 and Ar by using plasma enhanced chemical vapor deposition method. With the aid of X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR), the chemical bonding configuration, thermal stability and resistance to water of the films are explored

  9. Peculiarities of Production of Chromium Carbonitride Nanopowder and Its Physical-Chemical Certification

    International Nuclear Information System (INIS)

    Shiryaeva, L S; Nozdrin, I V; Galevsky, G V

    2015-01-01

    Scientific and technological basics of plasma synthesis of chromium carbonitride have been developed, including analysis of the current production state and application of chromium carbon compounds, defining characteristics of three-jet plasma reactor, modeling- mathematical study of interaction of raw materials and plasma streams, prediction of technological parameters of plasma stream based on the modeling results, selection of optimal technological option, implementation of plasma-metallurgical technology of chromium nitride production, its physical-chemical certification and defining technical-economical production factors. (paper)

  10. Plasma Enhanced Chemical Vapour Deposition of Horizontally Aligned Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Matthew T. Cole

    2013-05-01

    Full Text Available A plasma-enhanced chemical vapour deposition reactor has been developed to synthesis horizontally aligned carbon nanotubes. The width of the aligning sheath was modelled based on a collisionless, quasi-neutral, Child’s law ion sheath where these estimates were empirically validated by direct Langmuir probe measurements, thereby confirming the proposed reactors ability to extend the existing sheath fields by up to 7 mm. A 7 mbar growth atmosphere combined with a 25 W plasma permitted the concurrent growth and alignment of carbon nanotubes with electric fields of the order of 0.04 V μm−1 with linear packing densities of up to ~5 × 104 cm−1. These results open up the potential for multi-directional in situ alignment of carbon nanotubes providing one viable route to the fabrication of many novel optoelectronic devices.

  11. The kinetics of nonequilibrium chain plasma-chemical oxidation in heterogeneous media

    International Nuclear Information System (INIS)

    Deminskii, M.A.; Potapkin, B.V.; Rusanov, V.D.

    1994-01-01

    The kinetics of oxidation of low-impurity components in air mixtures under heterogeneous conditions was studied. The principal kinetic features of the process were determined on the basis of theoretical analysis of plasma-chemical oxidation in heterogeneous media. The analysis also showed that low concentrations of impurities in liquid aerosol particles can be efficiently oxidized via a chain process induced by reactive species formed in the gas

  12. Research on physical and chemical parameters of coolant in Light-Water Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Isabela C.; Mesquita, Amir Z., E-mail: icr@cdtn.br, E-mail: amir@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEM-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    The coolant radiochemical monitoring of light-water reactors, both power reactor as research reactors is one most important tasks of the system safe operation. The last years have increased the interest in the coolant chemical studying to optimize the process, to minimize the corrosion, to ensure the primary system materials integrity, and to reduce the workers exposure radiation. This paper has the objective to present the development project in Nuclear Technology Development Center (CDTN), which aims to simulate the primary water physical-chemical parameters of light-water-reactors (LWR). Among these parameters may be cited: the temperature, the pressure, the pH, the electric conductivity, and the boron concentration. It is also being studied the adverse effects that these parameters can result in the reactor integrity. The project also aims the mounting of a system to control and monitoring of temperature, electric conductivity, and pH of water in the Installation of Test in Accident Conditions (ITCA), located in the Thermal-Hydraulic Laboratory at CDTN. This facility was widely used in the years 80/90 for commissioning of several components that were installed in Angra 2 containment. In the test, the coolant must reproduce the physical and chemical conditions of the primary. It is therefore fundamental knowledge of the main control parameters of the primary cooling water from PWR reactors. Therefore, this work is contributing, with the knowledge and the reproduction with larger faithfulness of the reactors coolant in the experimental circuits. (author)

  13. Experimental study on plasma parameters in the mushroom limiter shadow in the T-10 tokamak

    International Nuclear Information System (INIS)

    Alferov, A.A.; Vershkov, V.A.; Grashin, S.A.; Chankin, A.V.

    1988-01-01

    Plasma parameters in the shadow of mashroom limiter installed in the lower tokamak outlet are studied. Investigation into asymmetry of plasma fluxes to the ion and electrone limiter sides leads to a consumption concerning two meachanisms of its occurrance-toroidal plasma rotation and prevailing plasma departure to the wall through the external torus encirclement. Asymmetry of plasma drift potentials near the limiter observed during the experiment leads to current drift through the limiter close to Spitzer j s one. It is shown that with the increase of mean plasma density the plasma density in the limiter channels grows and its temperature is decreased so the charged particle losses for the limiter are weakly dependent on the mean density which is connected with plasma confinement degradation under the density reduction. A complete flux of charged particles to the limiter is comparable to their flux from plasma filament. Plasma flux into the channels is close to ambipolar one and the power fluxes to neutralization plates are of the order of 10 j s Te/e. Neutral gas pressure dependence in the volume under the limiter on the plasma fluxes to channels is nonlinear, the maximum pressure achieves 3x10 -2 T

  14. [Measurement of plasma parameters in cluster hexagon pattern discharge by optical emission spectrum].

    Science.gov (United States)

    Dong, Li-Fang; Shen, Zhong-Kai; Li, Xin-Chun; Liu, Liang; Lu, Ning; Shang, Jie

    2012-09-01

    The cluster hexagon pattern was obtained in a dielectric barrier discharge in air/argon for the first time. Three plasma parameters, i. e. the molecular vibrational temperature, the molecular rotational temperature and the average electron energy of individual cluster in cluster hexagon pattern discharge, were studied by changing the air content. The molecular vibrational temperature and the molecular rotational temperature were calculated using the second positive band system of nitrogen molecules (C 3IIu --> B 3IIg) and the first negative band system of nitrogen molecular ions (B 2Sigma(u)+ --> Chi2 Sigma(g)+). The relative intensities of the first negative system of nitrogen molecular ions (391. 4 nm) and nitrogen molecules emission spectrum line (337.1 nm) were analyzed for studying the variations of the electron energy. It was found that the three plasma parameters of individual cluster in cluster hexagon pattern increase with air content increasing from 16% to 24%.

  15. Therapeutic effects of marshmallow (Althaea officinalis L.) extract on plasma biochemical parameters of common carp infected with Aeromonas hydrophila.

    Science.gov (United States)

    Banaee, Mahdi; Soleimany, Vahid; Nematdoost Haghi, Behzad

    2017-01-01

    This study evaluated preclinical and clinical safety of marshmallow ( Althaea officinalis L.) extract as a naturopathic medicine in common carp deliberately infected with Aeromonas hydrophila . The fish were fed 0 (control), 2.50, 5.00 and 10.00 g of marshmallow extract for 60 days in a preclinical experiment and then, challenged with A. hydrophila for a 10-day experiment. Significant increases were observed in aspartate aminotransferase (AST), lactate dehydrogenase (LDH), alkaline phosphatase (ALP), creatine phosphokinase (CPK) activities and plasma creatinine levels in fish fed 10 g marshmallow extract per kg feed. However, alanine aminotransferase (ALT) significantly decreased on day 60. The fish fed 2.50 g marshmallow extract per kg feed indicated increased levels of total protein and globulin. There were no significant changes in albumin levels ( p > 0.05). 2.50 and 5.00 g marshmallow significantly decreased triglyceride and cholesterol levels and increased glucose levels ( p Marshmallow extract at 5.00 and 10.00 g can adjust plasma biochemical parameters in fish challenged with A. hydrophila . The results of preclinical studies and pharmaceutical toxicity of marshmallow extract revealed that dietary levels lower than 5.00 g were safe and effective. The results of this clinical study demonstrated that marshmallow extract (5.00 g kg -1 feed) can protect fish against A. hydrophila .

  16. Neural network-based preprocessing to estimate the parameters of the X-ray emission of a single-temperature thermal plasma

    Science.gov (United States)

    Ichinohe, Y.; Yamada, S.; Miyazaki, N.; Saito, S.

    2018-04-01

    We present data preprocessing based on an artificial neural network to estimate the parameters of the X-ray emission spectra of a single-temperature thermal plasma. The method finds appropriate parameters close to the global optimum. The neural network is designed to learn the parameters of the thermal plasma (temperature, abundance, normalization and redshift) of the input spectra. After training using 9000 simulated X-ray spectra, the network has grown to predict all the unknown parameters with uncertainties of about a few per cent. The performance dependence on the network structure has been studied. We applied the neural network to an actual high-resolution spectrum obtained with Hitomi. The predicted plasma parameters agree with the known best-fitting parameters of the Perseus cluster within uncertainties of ≲10 per cent. The result shows that neural networks trained by simulated data might possibly be used to extract a feature built in the data. This would reduce human-intensive preprocessing costs before detailed spectral analysis, and would help us make the best use of the large quantities of spectral data that will be available in the coming decades.

  17. Investigation of deposition characteristics and properties of high-rate deposited silicon nitride films prepared by atmospheric pressure plasma chemical vapor deposition

    International Nuclear Information System (INIS)

    Kakiuchi, H.; Nakahama, Y.; Ohmi, H.; Yasutake, K.; Yoshii, K.; Mori, Y.

    2005-01-01

    Silicon nitride (SiN x ) films have been prepared at extremely high deposition rates by the atmospheric pressure plasma chemical vapor deposition (AP-PCVD) technique on Si(001) wafers from gas mixtures containing He, H 2 , SiH 4 and N 2 or NH 3 . A 150 MHz very high frequency (VHF) power supply was used to generate high-density radicals in the atmospheric pressure plasma. Deposition rate, composition and morphology of the SiN x films prepared with various deposition parameters were studied by scanning electron microscopy and Auger electron spectroscopy. Fourier transformation infrared (FTIR) absorption spectroscopy was also used to characterize the structure and the chemical bonding configurations of the films. Furthermore, etching rate with buffered hydrofluoric acid (BHF) solution, refractive index and capacitance-voltage (C-V) characteristics were measured to evaluate the dielectric properties of the films. It was found that effective passivation of dangling bonds and elimination of excessive hydrogen atoms at the film-growing surface seemed to be the most important factor to form SiN x film with a dense Si-N network. The C-V curve of the optimized film showed good interface properties, although further improvement was necessary for use in the industrial metal-insulator-semiconductor (MIS) applications

  18. Characterisation of silicon carbide films deposited by plasma-enhanced chemical vapour deposition

    International Nuclear Information System (INIS)

    Iliescu, Ciprian; Chen Bangtao; Wei Jiashen; Pang, A.J.

    2008-01-01

    The paper presents a characterisation of amorphous silicon carbide films deposited in plasma-enhanced chemical vapour deposition (PECVD) reactors for MEMS applications. The main parameter was optimised in order to achieve a low stress and high deposition rate. We noticed that the high frequency mode (13.56 MHz) gives a low stress value which can be tuned from tensile to compressive by selecting the correct power. The low frequency mode (380 kHz) generates high compressive stress (around 500 MPa) due to ion bombardment and, as a result, densification of the layer achieved. Temperature can decrease the compressive value of the stress (due to annealing effect). A low etching rate of the amorphous silicon carbide layer was noticed for wet etching in KOH 30% at 80 o C (around 13 A/min) while in HF 49% the layer is practically inert. A very slow etching rate of amorphous silicon carbide layer in XeF 2 -7 A/min- was observed. The paper presents an example of this application: PECVD-amorphous silicon carbide cantilevers fabricated using surface micromachining by dry-released technique in XeF 2

  19. Effect of different parameters governing the stability of drift wave in a magnetised plasma

    International Nuclear Information System (INIS)

    Elashkar, F.F.

    1990-01-01

    Influence of the governing parameters, such as electron drift parallel speed, parallel wave length, electron-neutral and ion-neutral collision frequencies, electron temperature and magnetic field, on the stability of drift wave in a magnetized plasma has been studied experimentally and theoretically using a full numerical solution of the exact equation. Drift wave has been excited by a positively biased grid; at a threshold grid potential secondary excitation and ionisation processes take place in the ejected beam of plasma. Effect of the applied magnetic field on the probability of these processes is discussed. Grid positive potential, electron-neutral collision, parallel wave length, electron temperature and speed are found to be destabilizing, While ion neutral collision is stabilizing. Using a new parameter β, the effect of magnetic field is investigated and it is destabilizing only upto a certain limit. (author). 11 figs., 21 refs

  20. X-Ray photoelectron spectroscopy analysis of plasma-polymer interactions for development of low-damage plasma processing of soft materials

    International Nuclear Information System (INIS)

    Setsuhara, Yuichi; Cho, Ken; Shiratani, Masaharu; Sekine, Makoto; Hori, Masaru

    2010-01-01

    Plasma-polymer interactions have been investigated using atomic force microscopy (AFM) and x-ray photoelectron spectroscopy (XPS) of polyethyleneterephthalate (PET) films, which have been exposed to argon plasmas driven by low-inductance antenna modules as a parameter of ion energy. The AFM images indicated that the argon plasma exposure exhibited a significant change in surface roughness. The XPS analyses suggested that the degradation of chemical bonding structure and/or bond scission of PET could be effectively suppressed in the plasma exposures with ion energies below 6 eV. However, significant degradations of O = C-O bond, C-O bond and phenyl group were observed with increasing ion energy above 6 eV.

  1. Physical and chemical properties of SSM-discharge in the system gas-liquid

    International Nuclear Information System (INIS)

    Chernyak, V.Ya.; Olszewski, S.V.; Evstigneev, M.A.; Tsybulev, P.N.; Voronin, P.N.

    1996-01-01

    Investigation on the influence of solved Na 2 SO 4 and NaOH concentrations on discharge plasma contacting solution, and on the influence of discharge parameters on metal precipitation speed, as well as chemical analysis of precipitant in the system plasma - water solution were performed. After plasma treatment of water solutions of Zn and Al nitrates flake-like and snow-white precipitations appear. Differential thermal and atom-adsorption analysis of precipitations show that metals precipitate as hydroxides. Investigation of the influence of SSM-discharge polarity on plasma-chemical precipitation efficiency show that positive polarity of liquid electrode is more preferable. Probably, this fact takes place because plasma electrode of the second subsystem is the cathode, and thus reactions of cations (metal ions) are more intensive near it. (authors)

  2. Experimental and numerical investigation of plasma parameters in the magnetosheath

    Directory of Open Access Journals (Sweden)

    Dobreva Polya

    2018-01-01

    Full Text Available We investigate the behaviour of the plasma parameters in the magnetosheath in a case when Interball-1 satellite stayed in the magnetosheath, crossing the tail magnetopause. In our analysis we apply the numerical magnetosheath-magnetosphere model as a theoretical tool. The bow shock and the magnetopause are self-consistently determined in the process of the solution. The flow in the magnetosheath is governed by the Euler equations of compressible ideal gas. The magnetic field in the magnetosphere is calculated by a variant of the Tsyganenko model, modified to account for an asymmetric magnetopause. Also, the magnetopause currents in Tsyganenko model are replaced by numericaly calulated ones. Measurements from WIND spacecraft are used as a solar wind monitor. The results demonstrate a good agreement between the model-calculated and measured values of the parameters under investigation.

  3. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    Science.gov (United States)

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  4. Clinical and prognostic significance of plasma fibrinogen in lung cancer

    Directory of Open Access Journals (Sweden)

    Chen YS

    2014-01-01

    Full Text Available Objectives: Hyperfibrinogenemia is a common problem associated with various carcinomas. The recent studies have shown that high plasma fibrinogen concentration is associated with invasion, growth and metastases of cancer. Furthermore, the recent studies focus on the prognostic significance of fibrinogen in the patients with advanced NSCLC (stage IIIB -IV. However, the prognostic significance of the plasma fibrinogen levels in early stage NSCLC patients (stage I -IIIA still remains unclear. In addition, it remains unclear whether or not chemotherapy-induced changes in fibrinogen level relate to the prognosis. The aims of this study were to 1 further explore the relationship between the plasma fibrinogen concentration and the stage and metastases of lung cancer 2 evaluate the prognostic significance of the basal plasma fibrinogen level in patients with lung cancer 3 explore the prognostic value of the change in fibrinogen levels between pre and post-chemotherapy. Methods: In this retrospective study, the data from 370 patients with lung cancer were enrolled into this study. The plasma fibrinogen levels were compared with the clinical and prognostic significance of lung cancer. The association between the plasma fibrinogen level and clinical-prognostic characteristics were analyzed using SPSS 17.0 software. Results: 1 The median pre-treatment plasma fibrinogen levels were 4.20g/L. Pre-treatment plasma fibrinogen levels correlated significantly with gender (p = 0.013. A higher plasma fibrinogen concentration was associated with squamous cell carcinoma versus adenocarcinoma (4.83±1.50 g/L versus 4.15±1.30 g/L; P<0.001, there was a significant association between plasma fibrinogen level and metastases of lung cancer, pointing a higher plasma fibrinogen level in lymph nodes or distant organ metastases (p < 0.001. 2 Patients with low plasma fibrinogen concentration demonstrates higher overall survival compared with those with high plasma fibrinogen

  5. Plasma for Electrification of Chemical Industry: a Case Study on CO2 Reduction

    NARCIS (Netherlands)

    van Rooij, G. J.; Akse, H.; Bongers, W.; van de Sanden, M. C. M.

    2018-01-01

    Significantly increasing the share of (intermittent) renewable power in the chemical industry is imperative to meet increasingly stricter limits on CO2 exhaust that are being implemented within Europe. This paper aims to evaluate the potential of a plasma process that converts input CO2 into a pure

  6. Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq

    Science.gov (United States)

    Al-Marzoki, Jasim M; Al-Maaroof, Zainab W; Kadhum, Ali H

    2012-01-01

    Background The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq. Methods A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks) and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually. Results Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3) g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6) × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472) × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count. Conclusion Most results in the current study were within the reference range. The hematological reference values for Iraqi neonatal cord plasma need to be confirmed by larger numbers of blood samples and by collecting samples from

  7. Preparation of Hydrophobic Metal-Organic Frameworks via Plasma Enhanced Chemical Vapor Deposition of Perfluoroalkanes for the Removal of Ammonia

    Science.gov (United States)

    DeCoste, Jared B.; Peterson, Gregory W.

    2013-01-01

    Plasma enhanced chemical vapor deposition (PECVD) of perfluoroalkanes has long been studied for tuning the wetting properties of surfaces. For high surface area microporous materials, such as metal-organic frameworks (MOFs), unique challenges present themselves for PECVD treatments. Herein the protocol for development of a MOF that was previously unstable to humid conditions is presented. The protocol describes the synthesis of Cu-BTC (also known as HKUST-1), the treatment of Cu-BTC with PECVD of perfluoroalkanes, the aging of materials under humid conditions, and the subsequent ammonia microbreakthrough experiments on milligram quantities of microporous materials. Cu-BTC has an extremely high surface area (~1,800 m2/g) when compared to most materials or surfaces that have been previously treated by PECVD methods. Parameters such as chamber pressure and treatment time are extremely important to ensure the perfluoroalkane plasma penetrates to and reacts with the inner MOF surfaces. Furthermore, the protocol for ammonia microbreakthrough experiments set forth here can be utilized for a variety of test gases and microporous materials. PMID:24145623

  8. Reconstruction of the ion plasma parameters from the current measurements: mathematical tool

    Directory of Open Access Journals (Sweden)

    E. Séran

    Full Text Available Instrument d’Analyse du Plasma (IAP is one of the instruments of the newly prepared ionospheric mission Demeter. This analyser was developed to measure flows of thermal ions at the altitude of ~ 750 km and consists of two parts: (i retarding potential analyser (APR, which is utilised to measure the energy distribution of the ion plasma along the sensor look direction, and (ii velocity direction analyser (ADV, which is used to measure the arrival angle of the ion flow with respect to the analyser axis. The necessity to obtain quick and precise estimates of the ion plasma parameters has prompted us to revise the existing mathematical tool and to investigate different instrumental limitations, such as (i finite angular aperture, (ii grid transparency, (iii potential depression in the space between the grid wires, (iv losses of ions during their passage between the entrance diaphragm and the collector. Simple analytical expressions are found to fit the currents, which are measured by the APR and ADV collectors, and show a very good agreement with the numerical solutions. It was proven that the fitting of the current with the model functions gives a possibility to properly resolve even minor ion concentrations and to find the arrival angles of the ion flow in the multi-species plasma. The discussion is illustrated by an analysis of the instrument response in the ionospheric conditions which are predicted by the International Reference Ionosphere (IRI model.

    Key words. Ionosphere (plasma convection; instruments and techniques – Space plasma physics (experimental and mathematical techniques

  9. Reconstruction of the ion plasma parameters from the current measurements: mathematical tool

    Directory of Open Access Journals (Sweden)

    E. Séran

    2003-05-01

    Full Text Available Instrument d’Analyse du Plasma (IAP is one of the instruments of the newly prepared ionospheric mission Demeter. This analyser was developed to measure flows of thermal ions at the altitude of ~ 750 km and consists of two parts: (i retarding potential analyser (APR, which is utilised to measure the energy distribution of the ion plasma along the sensor look direction, and (ii velocity direction analyser (ADV, which is used to measure the arrival angle of the ion flow with respect to the analyser axis. The necessity to obtain quick and precise estimates of the ion plasma parameters has prompted us to revise the existing mathematical tool and to investigate different instrumental limitations, such as (i finite angular aperture, (ii grid transparency, (iii potential depression in the space between the grid wires, (iv losses of ions during their passage between the entrance diaphragm and the collector. Simple analytical expressions are found to fit the currents, which are measured by the APR and ADV collectors, and show a very good agreement with the numerical solutions. It was proven that the fitting of the current with the model functions gives a possibility to properly resolve even minor ion concentrations and to find the arrival angles of the ion flow in the multi-species plasma. The discussion is illustrated by an analysis of the instrument response in the ionospheric conditions which are predicted by the International Reference Ionosphere (IRI model.Key words. Ionosphere (plasma convection; instruments and techniques – Space plasma physics (experimental and mathematical techniques

  10. Revisiting the quasi-particle model of the quark-gluon plasma

    International Nuclear Information System (INIS)

    Bannur, V.M.

    2007-01-01

    The quasi-particle model of the quark-gluon plasma (QGP) is revisited here with a new method, different from earlier studies, one without the need of a temperature dependent bag constant and other effects such as confinement, effective degrees of freedom etc. Our model has only one system dependent parameter and shows a surprisingly good fit to the lattice results for the gluon plasma, and for 2-flavor, 3-flavor and (2+1)-flavor QGP. The basic idea is first to evaluate the energy density ε from the grand partition function of quasi-particle QGP, and then derive all other thermodynamic functions from ε. Quasi-particles are assumed to have a temperature dependent mass equal to the plasma frequency. Energy density, pressure and speed of sound at zero chemical potential are evaluated and compared with the available lattice data. We further extend the model to a finite chemical potential, without any new parameters, to obtain the quark density, quark susceptibility etc., and the model fits very well with the lattice results on 2-flavor QGP. (orig.)

  11. Plasma-parameter measurements using neutral-particle-beam attenuation

    International Nuclear Information System (INIS)

    Foote, J.H.; Molvik, A.W.; Turner, W.C.

    1982-01-01

    Intense and energetic neutral-particle-beam injection used for fueling or heating magnetically confined, controlled-fusion experimental plasmas can also provide diagnostic measurements of the plasmas. The attenuation of an atomic beam (mainly from charge-exchange and ionization interactions) when passing through a plasma gives the plasma line density. Orthogonal arrays of highly collimated detectors of the secondary-electron-emission type have been used in magnetic-mirror experiments to measure neutral-beam attenuation along chords through the plasma volume at different radial and axial positions. The radial array is used to infer the radial plasma-density profile; the axial array, to infer the axial plasma-density profile and the ion angular distribution at the plasma midplane

  12. Estimation of The Physico-Chemical Parameters in Marine Environment (Yumurtalik Bight- Iskenderun Bay

    Directory of Open Access Journals (Sweden)

    Gökhan Tamer Kayaalp

    2016-02-01

    Full Text Available The study was carried out to estimate the temperature, light intensity, salinity, Dissolved O2 (DO, pH values and the biotic parameter chlorophyll- a in the water column related with the depth. Because, the physico-chemical parameters affect greatly both primary and secondary producers in marine life. For this purpose the physico-chemical properties were determined day and night for 40 meter depth during the eight days. The means were compared by using the analysis of variance method and Duncan’s Multiple Comparison Test. Also physico-chemical parameters were estimated by using the analysis of regression and correlation. The effect of temperature and salinity were found significant according to the result of the analysis of variance during the day. Also the similar results were found for the night. While the effect of the depth on the chloropyll-a a was significant in the night, the effect of the depth on the DO was not significant in the day and night. The correlations among the depth and the parameters were defined. It was found the negative correlation between the depth and the temperature and light intensity. Determination coefficient of the model for salinity was also found different for day time. The correlation values among the depth and the temperature, salinity and pH were found different for the night.

  13. On scattering diagnostics with periodically pulsed lasers to follow the continuous evolution of time dependent plasma parameters

    International Nuclear Information System (INIS)

    Hellermann, M. von; Hirsch, K.; Doeble, H.F.

    1977-04-01

    The possibilities to use periodically pulsed lasers for plasma scattering diagnostics are discussed. An experiment with succesful application of a periodically pulsed frequency-doubled Nd:YAG laser is described and results are given. Application of the method to monitor continuously, with millisecond time resolution, parameters of Tokamak type plasmas, is considered. (orig.) [de

  14. [Distribution of chemical elements in whole blood and plasma].

    Science.gov (United States)

    Barashkov, G K; Zaĭtseva, L I; Kondakhchan, M A; Konstantinova, E A

    2003-01-01

    The distribution factor (Fd) of 35 elements of plasma and whole blood in 26 healthy men and women was detected by ICP-OES. Usilig this parameter the elements were subdivided in 3 pools. 9 of them have Fd higher than 1.5 ("elements of plasma"-Ag, Ca, Cu, In, Li, Na, Se, Si, Sr); 6 have lower than 0.5 ("elements of blood cells"-Fe, K, Mn, Ni, V, Zn), other 20-about 1 ("blood elements"). Fd of all elements depends on ionic radius. Elements of 2nd sub-groups of all groups of Mendeleev's periodic table ("heavy metals") depend on the similar law: "with growing of ionic radius the concentration of elements in plasma enhances". In alkaline metals Fd depends on the opposite law:" with growing of ionic radius of alkaline metal the quantity of elements in blood cells enhance". Dependence of Fd on the value of atomic mass in periods or in exterior electronic cloud (s-, p-, d-, f-) was not established. The table of distribution of all detected elements in whole blood in relation to 8 macroelements (Ca, Mg, K, Na, S, P, Fe, Zn,) is presented, as a basic diagnostic criteria in metal-ligand homeostasis disturbance.

  15. EFFECT OF POLYMER PROSTHETIC CONSTRUCTION TREATED WITH GLOW-DISCHARGE PLASMA ON ORAL MUCOSA (CLINICAL CASE

    Directory of Open Access Journals (Sweden)

    E. O. Kudasova

    2017-01-01

    Full Text Available Prosthetic material should induce minimal pathological reaction when in contact with the oral mucosa, especially during oral rehabilitation of patients with tumors of the oral mucosa. The article presents monitoring of a patient after surgery for cancer of the buccal mucosa at the stage of orthopedic rehabilitation. Treatment plan proposed complex oral rehabilitation. A maxillary complete removable denture was manufactured as well as metalloceramic and partial mandibular dentures. Plasma chemical modification of the removable dentures was planned after correction of the prosthetics and primary adaptation. Removable dentures were applied at the maxilla and mandibula. Per our recommendations, the patient was examined weekly for a month and monthly for 6 months. No new tumors or pathological elements were observed.Conclusions. Changes in critical surface tension of the removable dentures made of acrylic plastic improve their biological characteristics as demonstrated by positive clinical dynamics. Prosthetic constructions with hydrophilic surface are recommended in complex clinical cases when patients with tumors of the oral mucosa require dentures.

  16. Design and construction the identification of nitriding plasma process parameters using personal computer based on serial communication

    International Nuclear Information System (INIS)

    Frida Iswinning Diah; Slamet Santosa

    2012-01-01

    Design and construction the identification of process parameters using personal computer based on serial communication PLC M-series has been done. The function of this device is to identify the process parameters of a system (plan), to which then be analyzed and conducted a follow-up given to the plan by the user. The main component of this device is the M-Series T100MD1616 PLC and personal computer (PC). In this device the data plan parameters obtained from the corresponding sensor outputs in the form of voltage or current. While the analog parameter data is adjusted to the ADC analog input of the PLC using a signal conditioning system. Then, as the parameter is processed by the PLC then sent to a PC via RS232 to be displayed in the form of graphs or tables and stored in the database. Software to program the database is created using Visual Basic Programming V-6. The device operation test is performed for the measurement of temperature parameter and vacuum level on the plasma nitriding machine. The results indicate that the device has functioning as an identification device parameters process of plasma nitriding machine. (author)

  17. Mathematical modeling of quartz particle melting process in plasma-chemical reactor

    Energy Technology Data Exchange (ETDEWEB)

    Volokitin, Oleg, E-mail: volokitin-oleg@mail.ru; Volokitin, Gennady, E-mail: vgg-tomsk@mail.ru; Skripnikova, Nelli, E-mail: nks2003@mai.ru; Shekhovtsov, Valentin, E-mail: shehovcov2010@yandex.ru [Tomsk State University of Architecture and Building, 2, Solyanaya Sq., 634003, Tomsk (Russian Federation); Vlasov, Viktor, E-mail: rector@tsuab.ru [Tomsk State University of Architecture and Building, 2, Solyanaya Sq., 634003, Tomsk (Russian Federation); National Research Tomsk Polytechnic University, 30, Lenin Ave., 634050, Tomsk (Russian Federation)

    2016-01-15

    Among silica-based materials vitreous silica has a special place. The paper presents the melting process of a quartz particle under conditions of low-temperature plasma. A mathematical model is designed for stages of melting in the experimental plasma-chemical reactor. As calculation data show, quartz particles having the radius of 0.21≤ r{sub p} ≤0.64 mm completely melt at W = 0.65 l/s particle feed rate depending on the Nusselt number, while 0.14≤ r{sub p} ≤0.44 mm particles melt at W = 1.4 l/s. Calculation data showed that 2 mm and 0.4 mm quartz particles completely melted during and 0.1 s respectively. Thus, phase transformations occurred in silicon dioxide play the important part in its heating up to the melting temperature.

  18. Plasma and liver acetaminophen-protein adduct levels in mice after acetaminophen treatment: Dose–response, mechanisms, and clinical implications

    International Nuclear Information System (INIS)

    McGill, Mitchell R.; Lebofsky, Margitta; Norris, Hye-Ryun K.; Slawson, Matthew H.; Bajt, Mary Lynn; Xie, Yuchao; Williams, C. David; Wilkins, Diana G.; Rollins, Douglas E.; Jaeschke, Hartmut

    2013-01-01

    At therapeutic doses, acetaminophen (APAP) is a safe and effective analgesic. However, overdose of APAP is the principal cause of acute liver failure in the West. Binding of the reactive metabolite of APAP (NAPQI) to proteins is thought to be the initiating event in the mechanism of hepatotoxicity. Early work suggested that APAP-protein binding could not occur without glutathione (GSH) depletion, and likely only at toxic doses. Moreover, it was found that protein-derived APAP-cysteine could only be detected in serum after the onset of liver injury. On this basis, it was recently proposed that serum APAP-cysteine could be used as diagnostic marker of APAP overdose. However, comprehensive dose–response and time course studies have not yet been done. Furthermore, the effects of co-morbidities on this parameter have not been investigated. We treated groups of mice with APAP at multiple doses and measured liver GSH and both liver and plasma APAP-protein adducts at various timepoints. Our results show that protein binding can occur without much loss of GSH. Importantly, the data confirm earlier work that showed that protein-derived APAP-cysteine can appear in plasma without liver injury. Experiments performed in vitro suggest that this may involve multiple mechanisms, including secretion of adducted proteins and diffusion of NAPQI directly into plasma. Induction of liver necrosis through ischemia–reperfusion significantly increased the plasma concentration of protein-derived APAP-cysteine after a subtoxic dose of APAP. While our data generally support the measurement of serum APAP-protein adducts in the clinic, caution is suggested in the interpretation of this parameter. - Highlights: • Extensive GSH depletion is not required for APAP-protein binding in the liver. • APAP-protein adducts appear in plasma at subtoxic doses. • Proteins are adducted in the cell and secreted out. • Coincidental liver injury increases plasma APAP-protein adducts at subtoxic doses

  19. Determination of clebopride in plasma by capillary gas chromatography-negative-ion chemical ionization mass spectrometry.

    Science.gov (United States)

    Robinson, P R; Jones, M D; Maddock, J

    1988-11-18

    A procedure for the analysis of clebopride in plasma using capillary gas chromatography-negative-ion chemical ionization mass spectrometry has been developed. Employing an ethoxy analogue as internal standard, the two compounds were extracted from basified plasma using dichloromethane. Subsequent reaction with heptafluorobutyryl imidazole produced volatile monoheptafluorobutyryl derivatives whose ammonia negative-ion mass spectra proved ideal for selected-ion monitoring. The recovery of clebopride from plasma at 0.536 nmol/l was found to be 85.5 +/- 0.9% (n = 3) whilst measurement down to 0.268 nmol/l was possible with a coefficient of variation of 7.9%. Plasma levels of the compound are reported in two volunteers following ingestion of 1 mg of clebopride as the malate salt.

  20. The effects of varying plasma parameters on silicon thin film growth by ECR plasma CVD

    International Nuclear Information System (INIS)

    Summers, S.; Reehal, H.S.; Shirkoohi, G.H.

    2001-01-01

    The technique of electron cyclotron resonance (ECR) plasma enhanced chemical vapour deposition (PECVD) is increasingly being used in electronic and photonic device applications. ECR offers a number of advantages including improved control of the deposition process, less damage to the growing film and the possibility of high deposition rates. ECR occurs in a plasma under appropriate magnetic and electric field conditions. In most cases, as in our system, this is achieved with a combination of 2.45 GHz microwave radiation and a 0.0875 T magnetic field, due to the use of standardized microwave supplies. We have studied the effects on silicon film growth of changing the magnetic field configuration to produce one or more planes of ECR within the system, and of changing the positions of the plane(s) relative to the deposition substrate. The films were grown in silane-hydrogen discharges. The magnetic field in our system was provided by two electromagnets. It was measured experimentally for a number of operating current values and then a detailed profile achieved by modelling using a proprietary software package. A process condition discharge under identical magnetic field configurations to growth was analysed by the use of a Langmuir probe and the results correlated with film properties determined by Raman spectroscopy and Dektak profilometry. (author)

  1. The producing of an ECR plasma using 2450MHz Whistler Wave and the investigating of its parameters

    International Nuclear Information System (INIS)

    Fang Yude; Zhang Jiande; Fu Keming; Lu Xiangyu; Liu Dengcheng; Wang Xianyu; Xie Weidong; Bao Dinghua; Yin Xiejin

    1988-12-01

    A stable ECR plasma was produced and sustained in HER mirror using 2450MHz Whistler wave. The parameters of the ECR plasma and their chaining characters were studied in detail and were compared with those of the DC discharge plasmas. The conclusion is that the ECR plasma is a high ionizability, low temperature, middle density plasma, its peak density may much exceed the cutoff density of the pump wave (when ω = ω pe ) and arrive at the order of 10 12 cm -3 . The ECR plasma includes some high energy hot electrons (20Kev-200Kev) and middle energy warm electrons (< 20Kev). Those two kinds of electron created some strong X-ray emissions in a wide frequency range. The ECR plasma has higher edge density and can strongly interact with the wall. (author). 9 refs, 17 figs

  2. Clinical value of indicators of cationic proteins, leukocytes myeloperoxidase and fibronectin blood plasma in viral meningitis in children

    Directory of Open Access Journals (Sweden)

    O. G. Kimirilova

    2017-01-01

    Full Text Available Objective: was to establish clinical and diagnostic value of cytochemical indices of peripheral blood leukocytes (cationic protein and myeloperoxidase, fibronectin blood plasma to assess the severity, predict the course and outcome of viral meningitis in children.Subjects and methods. In 450 patients with viral meningitis (enterovirus, arbovirus, parotitic, herpesviral, adenovirus etiology at the age of 14 years, the parameters of the microbicidal system of leukocytes (cation proteins, myeloperoxidase and fibronectin blood plasma were determined. Etiological diagnosis of meningitis was confirmed by release of viral RNA from blood and cerebrospinal fluid by the polymerase chain reaction, enzyme-linked immunosorbent assay (ELISA.The results and conclusion. Found that severe, prolonged duration, lethal outcome of viral meningitis in children are accompanied by sugnificant suppression of cationic proteins, myeloperoxidase, fibronectin blood plasma, maximally expressed in lethal outcomes, compared with the severe form, but with a favorable outcome and control. Settings imbalance cationic proteins, myeloperoxidase, fibronectin blood plasma are objective criteria of the adaptation syndrome that reflects the state of the phagocytosis system in viral meningitis in children and can be considered as additional criteria for predicting the course and outcome of disease.

  3. Determination of Stark parameters by cross-calibration in a multi-element laser-induced plasma

    Science.gov (United States)

    Liu, Hao; Truscott, Benjamin S.; Ashfold, Michael N. R.

    2016-05-01

    We illustrate a Stark broadening analysis of the electron density Ne and temperature Te in a laser-induced plasma (LIP), using a model free of assumptions regarding local thermodynamic equilibrium (LTE). The method relies on Stark parameters determined also without assuming LTE, which are often unknown and unavailable in the literature. Here, we demonstrate that the necessary values can be obtained in situ by cross-calibration between the spectral lines of different charge states, and even different elements, given determinations of Ne and Te based on appropriate parameters for at least one observed transition. This approach enables essentially free choice between species on which to base the analysis, extending the range over which these properties can be measured and giving improved access to low-density plasmas out of LTE. Because of the availability of suitable tabulated values for several charge states of both Si and C, the example of a SiC LIP is taken to illustrate the consistency and accuracy of the procedure. The cross-calibrated Stark parameters are at least as reliable as values obtained by other means, offering a straightforward route to extending the literature in this area.

  4. 20180318 - Prediction Of pKa From Chemical Structure Using Free And Open-Source Tools (ACS Spring)

    Science.gov (United States)

    The ionization state of a chemical, reflected in pKa values, affects lipophilicity, solubility, protein binding and the ability of a chemical to cross the plasma membrane. These properties govern the pharmacokinetic parameters such as absorption, distribution, metabolism, excreti...

  5. One-step synthesis of chlorinated graphene by plasma enhanced chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Liwei; Zhang, Hui; Zhang, Pingping; Sun, Xuhui, E-mail: xhsun@suda.edu.cn

    2015-08-30

    Highlights: • We developed a simple approach to synthesize the single layer chlorinated graphene. • CuCl{sub 2} on Cu surface is used as Cl source under the plasma treatment. • The formation of covalent C−Cl bond has been investigated by Raman and XPS. • Raman results indicate the p-type doping effect of chlorination. - Abstract: We developed an approach to synthesize the chlorinated single layer graphene (Cl-G) by one-step plasma enhanced chemical vapor deposition. Copper foil was simply treated with hydrochloric acid and then CuCl{sub 2} formed on the surface was used as Cl source under the assistance of plasma treatment. Compared with other two-step methods by post plasma/photochemical treatment of CVD-grown single layer graphene (SLG), one-step Cl-G synthesis approach is quite straightforward and effective. X-ray photoelectron spectroscopy (XPS) revealed that ∼2.45 atom% Cl remained in SLG. Compared with the pristine SLG, the obvious blue shifts of G band and 2D band along with the appearance of D’ band and D + G band in the Raman spectra indicate p-type doping of Cl-G.

  6. Plasma enhanced chemical vapor deposition silicon oxynitride optimized for application in integrated optics

    NARCIS (Netherlands)

    Worhoff, Kerstin; Driessen, A.; Lambeck, Paul; Hilderink, L.T.H.; Linders, Petrus W.C.; Popma, T.J.A.

    1999-01-01

    Silicon Oxynitride layers are grown from SiH4/N2, NH3 and N2O by Plasma Enhanced Chemical Vapor Deposition. The process is optimized with respect to deposition of layers with excellent uniformity in the layer thickness, high homogeneity of the refractive index and good reproducibility of the layer

  7. Optimization of process parameters for spark plasma sintering of nano structured SAF 2205 composite

    Directory of Open Access Journals (Sweden)

    Samuel Ranti Oke

    2018-04-01

    Full Text Available This research optimized spark plasma sintering (SPS process parameters in terms of sintering temperature, holding time and heating rate for the development of a nano-structured duplex stainless steel (SAF 2205 grade reinforced with titanium nitride (TiN. The mixed powders were sintered using an automated spark plasma sintering machine (model HHPD-25, FCT GmbH, Germany. Characterization was performed using X-ray diffraction and scanning electron microscopy. Density and hardness of the composites were investigated. The XRD result showed the formation of FeN0.068. SEM/EDS revealed the presence of nano ranged particles of TiN segregated at the grain boundaries of the duplex matrix. A decrease in hardness and densification was observed when sintering temperature and heating rate were 1200 °C and 150 °C/min respectively. The optimum properties were obtained in composites sintered at 1150 °C for 15 min and 100 °C/min. The composite grades irrespective of the process parameters exhibited similar shrinkage behavior, which is characterized by three distinctive peaks, which is an indication of good densification phenomena. Keywords: Spark plasma sintering, Duplex stainless steel (SAF 2205, Titanium nitride (TiN, Microstructure, Density, Hardness

  8. Coaxial discharge plasma parameters and radiation emission

    International Nuclear Information System (INIS)

    Solimen, H.M.

    1993-01-01

    Results are reported for experiments carried out on a Mather type coaxial discharge plasma device. Experimental measurements of the electron temperature and density for the plasma propagated from the coaxial discharge are determined by using a biased double electric probe. The experimental results illustrated that , there are two groups of the plasma in the ejected plasma bulk, at 9 cm from the muzzle axis, the plasma reached the probe at 20 μsec from the start of discharge. The first group has electron temperature and density 27 eV and 3 x 10 14 cm -3 respectively,while The second group has 25 eV and 3 x 10 14 cm -3 respectively. The decay rate of the electron temperature and density of each group is presented. The plasma radiation spectrum is detected by a dielectric filter at 3500 A degree or 6100 A degree . The experimental measurements showed that, without or with dielectric filters, the visible radiation consists from two pulses with different magnitudes within the same half cycle of discharge. The time resolution of the soft x-ray is achieved by means of scintillator detector. The detected x-ray pulse during the first half cycle of discharge had a double peaks with different structures. All the experimental results present in this paper showed that the plasma bulk propagated in the expansion chamber, consists of two-groups. 6 fig

  9. Hydraulic and Groundwater Chemical Parameters of the Aquifer in Malakasari, Bandung

    Directory of Open Access Journals (Sweden)

    Ahnaf Jemi S.

    2018-01-01

    Full Text Available In order to reveal the physical condition of the aquifer, the pumping test using Cooper-Jacob (1946 principle has conducted at well SM5. The observation data of the test then processed to generate various value of hydraulic properties i.e. 3.241x10-4 cm2/sec for transmissivity (T, 8.103x10-6 cm/sec for conductivity (K, 0.05055 for storativity (S, and 3.852x10-3 ft-1 for specific storage (Ss. These data show that the aquifer composed of unconsolidated sedimentary rocks ranged from coarse sand to silt. In addition, also performed the feasibility test of groundwater by using Multimeter which produces chemical parameter data. The chemical parameter of eight well samples have average values of 6.62, 766.25 μs/cm and 376.25 mg/L for pH, electric conductivity (EC, and total dissolved solid (TDS respectively, while physical observation shows no turbidity and odor.

  10. What Clinical and Laboratory Parameters Distinguish Between ...

    African Journals Online (AJOL)

    Introduction: In developing countries, a large number of patients presenting acutely in renal failure are indeed cases of advanced chronic renal failure. In this study, we compared clinical and laboratory parameters between patients with acute renal failure (ARF) and chronic renal failure (CRF), to identify discriminatory ...

  11. Prediction of chemical, physical and sensory data from process parameters for frozen cod using multivariate analysis

    DEFF Research Database (Denmark)

    Bechmann, Iben Ellegaard; Jensen, H.S.; Bøknæs, Niels

    1998-01-01

    Physical, chemical and sensory quality parameters were determined for 115 cod (Gadus morhua) samples stored under varying frozen storage conditions. Five different process parameters (period of frozen storage, frozen storage. temperature, place of catch, season for catching and state of rigor) were...... varied systematically at two levels. The data obtained were evaluated using the multivariate methods, principal component analysis (PCA) and partial least squares (PLS) regression. The PCA models were used to identify which process parameters were actually most important for the quality of the frozen cod....... PLS models that were able to predict the physical, chemical and sensory quality parameters from the process parameters of the frozen raw material were generated. The prediction abilities of the PLS models were good enough to give reasonable results even when the process parameters were characterised...

  12. Evaluation of metabolism, plasma protein binding and other biological parameters after administration of (−)-[18 F]Flubatine in humans

    International Nuclear Information System (INIS)

    Patt, Marianne; Becker, Georg A.; Grossmann, Udo; Habermann, Bernd; Schildan, Andreas; Wilke, Stephan; Deuther-Conrad, Winnie; Graef, Susanne; Fischer, Steffen; Smits, René; Hoepping, Alexander; Wagenknecht, Gudrun; Steinbach, Jörg; Gertz, Hermann-Josef; Hesse, Swen; Schönknecht, Peter

    2014-01-01

    Introduction: (−)-[ 18 F]Flubatine is a PET tracer with high affinity and selectivity for the nicotinic acetylcholine α 4 β 2 receptor subtype. A clinical trial assessing the availability of this subtype of nAChRs was performed. From a total participant number of 21 Alzheimer’s disease (AD) patients and 20 healthy controls (HCs), the following parameters were determined: plasma protein binding, metabolism and activity distribution between plasma and whole blood. Methods: Plasma protein binding and fraction of unchanged parent compound were assessed by ultracentrifugation and HPLC, respectively. The distribution of radioactivity (parent compound + metabolites) between plasma and whole blood was determined ex vivo at different time-points after injection by gamma counting after separation of whole blood by centrifugation into the cellular and non-cellular components. In additional experiments in vitro, tracer distribution between these blood components was assessed for up to 90 min. Results: A fraction of 15% ± 2% of (−)-[ 18 F]Flubatine was found to be bound to plasma proteins. Metabolic degradation of (−)-[ 18 F]Flubatine was very low, resulting in almost 90% unchanged parent compound at 90 min p.i. with no significant difference between AD and HC. The radioactivity distribution between plasma and whole blood changed in vivo only slightly over time from 0.82 ± 0.03 at 3 min p.i. to 0.87 ± 0.03 at 270 min p.i. indicating the contribution of only a small amount of metabolites. In vitro studies revealed that (−)-[ 18 F]Flubatine was instantaneously distributed between cellular and non-cellular blood parts. Discussion: (−)-[ 18 F]Flubatine exhibits very favourable characteristics for a PET radiotracer such as slow metabolic degradation and moderate plasma protein binding. Equilibrium of radioactivity distribution between plasma and whole blood is reached instantaneously and remains almost constant over time allowing both convenient sample handling and

  13. Diagnostic utility of clinical and biochemical parameters in ...

    African Journals Online (AJOL)

    Diagnostic utility of clinical and biochemical parameters in pancreatic head malignancy ... Department of Surgery, Sir Run Run Shaw Hospital College of Medicine, Zhejiang University, ..... technical review on the epidemiology, diagnosis, and.

  14. Rocket measurements within a polar cap arc - Plasma, particle, and electric circuit parameters

    Science.gov (United States)

    Weber, E. J.; Ballenthin, J. O.; Basu, S.; Carlson, H. C.; Hardy, D. A.; Maynard, N. C.; Kelley, M. C.; Fleischman, J. R.; Pfaff, R. F.

    1989-01-01

    Results are presented from the Polar Ionospheric Irregularities Experiment (PIIE), conducted from Sondrestrom, Greenland, on March 15, 1985, designed for an investigation of processes which lead to the generation of small-scale (less than 1 km) ionospheric irregularities within polar-cap F-layer auroras. An instrumented rocket was launched into a polar cap F layer aurora to measure energetic electron flux, plasma, and electric circuit parameters of a sun-aligned arc, coordinated with simultaneous measurements from the Sondrestrom incoherent scatter radar and the AFGL Airborne Ionospheric Observatory. Results indicated the existence of two different generation mechanisms on the dawnside and duskside of the arc. On the duskside, parameters are suggestive of an interchange process, while on the dawnside, fluctuation parameters are consistent with a velocity shear instability.

  15. High Throughput Plasma Water Treatment

    Science.gov (United States)

    Mujovic, Selman; Foster, John

    2016-10-01

    The troublesome emergence of new classes of micro-pollutants, such as pharmaceuticals and endocrine disruptors, poses challenges for conventional water treatment systems. In an effort to address these contaminants and to support water reuse in drought stricken regions, new technologies must be introduced. The interaction of water with plasma rapidly mineralizes organics by inducing advanced oxidation in addition to other chemical, physical and radiative processes. The primary barrier to the implementation of plasma-based water treatment is process volume scale up. In this work, we investigate a potentially scalable, high throughput plasma water reactor that utilizes a packed bed dielectric barrier-like geometry to maximize the plasma-water interface. Here, the water serves as the dielectric medium. High-speed imaging and emission spectroscopy are used to characterize the reactor discharges. Changes in methylene blue concentration and basic water parameters are mapped as a function of plasma treatment time. Experimental results are compared to electrostatic and plasma chemistry computations, which will provide insight into the reactor's operation so that efficiency can be assessed. Supported by NSF (CBET 1336375).

  16. Dry-plasma-free chemical etch technique for variability reduction in multi-patterning (Conference Presentation)

    Science.gov (United States)

    Kal, Subhadeep; Mohanty, Nihar; Farrell, Richard A.; Franke, Elliott; Raley, Angelique; Thibaut, Sophie; Pereira, Cheryl; Pillai, Karthik; Ko, Akiteru; Mosden, Aelan; Biolsi, Peter

    2017-04-01

    Scaling beyond the 7nm technology node demands significant control over the variability down to a few angstroms, in order to achieve reasonable yield. For example, to meet the current scaling targets it is highly desirable to achieve sub 30nm pitch line/space features at back-end of the line (BEOL) or front end of line (FEOL); uniform and precise contact/hole patterning at middle of line (MOL). One of the quintessential requirements for such precise and possibly self-aligned patterning strategies is superior etch selectivity between the target films while other masks/films are exposed. The need to achieve high etch selectivity becomes more evident for unit process development at MOL and BEOL, as a result of low density films choices (compared to FEOL film choices) due to lower temperature budget. Low etch selectivity with conventional plasma and wet chemical etch techniques, causes significant gouging (un-intended etching of etch stop layer, as shown in Fig 1), high line edge roughness (LER)/line width roughness (LWR), non-uniformity, etc. In certain circumstances this may lead to added downstream process stochastics. Furthermore, conventional plasma etches may also have the added disadvantage of plasma VUV damage and corner rounding (Fig. 1). Finally, the above mentioned factors can potentially compromise edge placement error (EPE) and/or yield. Therefore a process flow enabled with extremely high selective etches inherent to film properties and/or etch chemistries is a significant advantage. To improve this etch selectivity for certain etch steps during a process flow, we have to implement alternate highly selective, plasma free techniques in conjunction with conventional plasma etches (Fig 2.). In this article, we will present our plasma free, chemical gas phase etch technique using chemistries that have high selectivity towards a spectrum of films owing to the reaction mechanism ( as shown Fig 1). Gas phase etches also help eliminate plasma damage to the

  17. Chemical interaction and adhesion characteristics at the interface of metals (Cu, Ta) and low-k cyclohexane-based plasma polymer (CHexPP) films

    International Nuclear Information System (INIS)

    Kim, K.J.; Kim, K.S.; Lee, N.-E.; Choi, J.; Jung, D.

    2001-01-01

    Chemical interaction and adhesion characteristics between metals (Cu, Ta) and low-k plasma-treated cyclohexane-based plasma polymer (CHexPP) films were studied. In order to generate new functional groups that may contribute to the improvement of adhesion between metal and plasma polymer, we performed O 2 , N 2 , and H 2 /He mixture plasma treatment on the surfaces of CHexPP films. Chemical interactions at the interface between metals (Cu, Ta) and plasma-treated CHexPP films were analyzed by x-ray photoelectron spectroscopy. The effect of plasma treatment and thermal annealing on the adhesion characteristics was measured by a tape test and scratch test. The formation of new binding states on the surface of plasma-treated CHexPP films improved adhesion characteristics between metals and CHexPP films. Thermal annealing improves the adhesion property of Cu/CHexPP films, but degrades the adhesion property of Ta/CHexPP films

  18. Effect of oxygen plasma on field emission characteristics of single-wall carbon nanotubes grown by plasma enhanced chemical vapour deposition system

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Avshish; Parveen, Shama; Husain, Samina; Ali, Javid; Zulfequar, Mohammad [Department of Physics, Jamia Millia Islamia (A Central University), New Delhi 110025 (India); Harsh [Centre for Nanoscience and Nanotechnology, Jamia Millia Islamia, New Delhi 110025 (India); Husain, Mushahid, E-mail: mush-reslab@rediffmail.com [Department of Physics, Jamia Millia Islamia (A Central University), New Delhi 110025 (India); Centre for Nanoscience and Nanotechnology, Jamia Millia Islamia, New Delhi 110025 (India)

    2014-02-28

    Field emission properties of single wall carbon nanotubes (SWCNTs) grown on iron catalyst film by plasma enhanced chemical vapour deposition system were studied in diode configuration. The results were analysed in the framework of Fowler-Nordheim theory. The grown SWCNTs were found to be excellent field emitters, having emission current density higher than 20 mA/cm{sup 2} at a turn-on field of 1.3 V/μm. The as grown SWCNTs were further treated with Oxygen (O{sub 2}) plasma for 5 min and again field emission characteristics were measured. The O{sub 2} plasma treated SWCNTs have shown dramatic improvement in their field emission properties with emission current density of 111 mA/cm{sup 2} at a much lower turn on field of 0.8 V/μm. The as grown as well as plasma treated SWCNTs were also characterized by various techniques, such as scanning electron microscopy, high resolution transmission electron microscopy, Raman spectroscopy, and Fourier transform infrared spectroscopy before and after O{sub 2} plasma treatment and the findings are being reported in this paper.

  19. The clinical significance of determining the plasma superoxide dismutase and neuropeptide Y in newborn hypoxic-ischemic encephalopathy

    International Nuclear Information System (INIS)

    Xu Xuezhong; Cui Zhenxing

    2002-01-01

    Objective: To investigate the contents of plasma superoxide dismutase (SOD) and neuropeptide Y (NPY) in newborn hypoxic-ischemic encephalopathy (HIE) babies in various clinic stages and their clinical significance. Methods: The plasma levels of SOD and NPY of 63 HIE babies and controls were determined by radioimmunoassay (RIA) and the values were studied for different clinical stages (severe 22, moderate 7 and mild 24). Results: The contents of plasma SOD and NPY of HIE babies of various stages were different and there existed remarkable contrast between those in patients and controls (p<0.05 or p<0.01). Conclusion: The contents of plasma SOD and NPY in HIE neonates were correlated to the clinic stage and severeness of the disease process

  20. Jet quenching parameter in an expanding QCD plasma arXiv

    CERN Document Server

    Iancu, Edmond; Wu, Bin

    We study the phenomenon of transverse momentum broadening for a high-$p_T$ parton propagating through a weakly-coupled quark-gluon plasma undergoing boost-invariant longitudinal expansion. We propose a boost-invariant description for this phenomenon, in which the broadening refers to the angular variables $\\eta$ (the pseudo-rapidity) and $\\phi$ (the azimuthal angle). The jet quenching parameter $\\hat{q}$ which enters this description depends upon the proper time alone. We furthermore consider radiative corrections to $\\hat q$. As in the case of a static medium, we find potentially large corrections enhanced by a double logarithm. But unlike for the static medium, these corrections are now local in time: they depend upon the local (proper) time characterizing the expansion, and not upon the overall path length. We resum such corrections to all orders into a renormalized jet quenching parameter. The main effect of this resummation is to slow down the decrease of $\\hat q$ with increasing proper time.

  1. Time-dependent two-temperature chemically non-equilibrium modelling of high-power Ar-N2 pulse-modulated inductively coupled plasmas at atmospheric pressure

    International Nuclear Information System (INIS)

    Tanaka, Yasunori

    2006-01-01

    A time-dependent, two-dimensional, two-temperature and chemical non-equilibrium model was developed for high-power Ar-N 2 pulse-modulated inductively coupled plasmas (PMICPs) at atmospheric pressure. The high-power PMICP is a new technique for sustaining high-power induction plasmas. It can control the plasma temperature and radical densities in the time domain. The PMICP promotes non-equilibrium effects by a sudden application of electric field, even in the high-power density plasmas. The developed model accounts separately for the time-dependent energy conservation equations of electrons and heavy particles. This model also considers reaction heat effects and energy transfer between electrons and heavy particles as well as enthalpy flow resulting from diffusion caused by the particle density gradient. Chemical non-equilibrium effects are also taken into account by solving time-dependent mass conservation equations for each particle, considering diffusion, convection and net production terms resulting from 30 chemical reactions. Transport and thermodynamic properties of Ar-N 2 plasmas are calculated self-consistently using the first order approximation of the Chapman-Enskog method at each position and iteration using the local particle composition, heavy particle temperature and electron temperature. This model is useful to discuss time evolution in temperature, gas flow fields and distribution of chemical species

  2. Plasma diagnostics and device properties of AlGaN/GaN HEMT passivated with SiN deposited by plasma-enhanced chemical vapour deposition

    Energy Technology Data Exchange (ETDEWEB)

    Romero, M F; Sanz, M M; Munoz, E [ISOM-Universidad Politecnica de Madrid (UPM). ETSIT, Madrid (Spain); Tanarro, I [Instituto de Estructura de la Materia, CSIC, Madrid (Spain); Jimenez, A, E-mail: itanarro@iem.cfmac.csic.e [Departamento Electronica, Escuela Politecnica Superior, Universidad de Alcala, Alcala de Henares, Madrid (Spain)

    2010-12-15

    In this work, silicon nitride thin films have been deposited by plasma enhanced chemical vapour deposition on both silicon samples and AlGaN/GaN high electron mobility transistors (HEMT) grown on sapphire substrates. Commercial parallel-plate RF plasma equipment has been used. During depositions, the dissociation rates of SiH{sub 4} and NH{sub 3} precursors and the formation of H{sub 2} and N{sub 2} have been analysed by mass spectrometry as a function of the NH{sub 3}/SiH{sub 4} flow ratio and the RF power applied to the plasma reactor. Afterwards, the properties of the films and the HEMT electrical characteristics have been studied. Plasma composition has been correlated with the SiN deposition rate, refractive index, H content and the final electric characteristics of the passivated transistors.

  3. Variations of some parameters of enzyme induction in chemical workers

    Energy Technology Data Exchange (ETDEWEB)

    Dolara, P. (Univ. of Florence, Italy); Lodovici, M.; Buffoni, F.; Buiatti, E.; Baccetti, S.; Ciofini, O.; Bavazzano, P.; Barchielli, S.; Vannucci, V.

    1982-01-01

    Several parameters related to mono-oxygenase activity were followed in a population of chemical workers and controls. Workers exposed to toluene and xylene had a significant increase of urinary glucaric acid, that was correlated with hippuric acid excretion. On the other hand, workers exposed to pigments showed a marked increase of antipyrine half-life. A dose-related decrease of liver N-demethylase was induced in rats by the administration of a mixture of three of the pigments in use in the plant. Serum gamma-glutamyltranspeptidase was decreased in the workers exposed to pigments, but this variation was not statistically significant. The exposure to different chemicals in the workplace seemed to induce a complicated variation of mono-oxygenase levels, some enzyme being inhibited and others induced in the same group of workers. The sensitivity of these workers to toxic effects of chemicals, carcinogenic compounds and drugs seems to differ markedly from the control population.

  4. X-ray structural analysis of plasma sprayed europium oxide

    Energy Technology Data Exchange (ETDEWEB)

    Gorshkov, B.N.; Loskutov, V.S.; Gavrish, A.A.; Shakh, G.E.

    1981-12-01

    An X-ray structure microanalysis is made for europium oxide powder produced by sintering and plasmic spheroidization for plasma spraying. The technique of concern is shown not to alter chemical composition of the powder. It is stated that a rise in the plasma jet enthalpy while spraying does not result in dissociation of europium oxide and its interaction with the plasma flux. The coating (to 15.2 kWxs/g) is found to have only a high-temperature (monoclinic) europium oxide phase and there appears a low-temperature (cubic) phase with a subsequent increase in the enthalpy. The plasma jet enthalpy increasing the grain size and the crystal lattice c parameter of the sprayed europium oxide are shown to decrease; the a parameter reduces with an enthalpy growth to 16.2 kW s/g and then smoothly increases with the enthalpy further growth. It is noticed that the europium oxide coating does not interact with an aluminium D16 alloy substrate.

  5. Time-Resolved Quantum Cascade Laser Absorption Spectroscopy of Pulsed Plasma Assisted Chemical Vapor Deposition Processes Containing BCl3

    Science.gov (United States)

    Lang, Norbert; Hempel, Frank; Strämke, Siegfried; Röpcke, Jürgen

    2011-08-01

    In situ measurements are reported giving insight into the plasma chemical conversion of the precursor BCl3 in industrial applications of boriding plasmas. For the online monitoring of its ground state concentration, quantum cascade laser absorption spectroscopy (QCLAS) in the mid-infrared spectral range was applied in a plasma assisted chemical vapor deposition (PACVD) reactor. A compact quantum cascade laser measurement and control system (Q-MACS) was developed to allow a flexible and completely dust-sealed optical coupling to the reactor chamber of an industrial plasma surface modification system. The process under the study was a pulsed DC plasma with periodically injected BCl3 at 200 Pa. A synchronization of the Q-MACS with the process control unit enabled an insight into individual process cycles with a sensitivity of 10-6 cm-1·Hz-1/2. Different fragmentation rates of the precursor were found during an individual process cycle. The detected BCl3 concentrations were in the order of 1014 molecules·cm-3. The reported results of in situ monitoring with QCLAS demonstrate the potential for effective optimization procedures in industrial PACVD processes.

  6. Plasma flow reactor for steady state monitoring of physical and chemical processes at high temperatures.

    Science.gov (United States)

    Koroglu, Batikan; Mehl, Marco; Armstrong, Michael R; Crowhurst, Jonathan C; Weisz, David G; Zaug, Joseph M; Dai, Zurong; Radousky, Harry B; Chernov, Alex; Ramon, Erick; Stavrou, Elissaios; Knight, Kim; Fabris, Andrea L; Cappelli, Mark A; Rose, Timothy P

    2017-09-01

    We present the development of a steady state plasma flow reactor to investigate gas phase physical and chemical processes that occur at high temperature (1000 flow injector). We have modeled the system using computational fluid dynamics simulations that are bounded by measured temperatures. In situ line-of-sight optical emission and absorption spectroscopy have been used to determine the structures and concentrations of molecules formed during rapid cooling of reactants after they pass through the plasma. Emission spectroscopy also enables us to determine the temperatures at which these dynamic processes occur. A sample collection probe inserted from the open end of the reactor is used to collect condensed materials and analyze them ex situ using electron microscopy. The preliminary results of two separate investigations involving the condensation of metal oxides and chemical kinetics of high-temperature gas reactions are discussed.

  7. Effect of plasma spraying parameter on wear resistance of NiCrBSiCFe plasma coatings on austenitic stainless steel at elevated temperatures at various loads

    International Nuclear Information System (INIS)

    Parthasarathi, N.L.; Duraiselvam, Muthukannan; Borah, Utpal

    2012-01-01

    Highlights: ► Effect of plasma spraying parameters, especially the stand-off distance. ► Effect of microstructure and applied load on coating in sliding wear. ► The reason for maximum wear rate at 250 °C and the minimum wear at 350 °C were explained. ► The worn debris were characterised by SEM analysis and correlated with wear rate. -- Abstract: The dry sliding wear tests were carried out on AISI 316 austenitic stainless steel (ASS) plasma coated with NiCrBSiCFe alloy powder under two set of plasma spraying parameters (PSP-1 and PSP-2). EN 8 medium carbon steel was used as a counterface material. The tests were carried out at loads of 20 N and 40 N with a constant sliding velocity of 1 m/s at room temperature (35°), 150 °C, 250 °C and 350 °C. Metallographic characterisation was carried out by optical microscope (OM), scanning electron microscope (SEM) and X-ray diffraction (XRD). Between the two plasma parameters tested, stand-off distance of 125 mm was found to be more suitable for producing uniform lamellar microstructure with fewer amounts of pores which shows better wear resistance. The wear rate at 250 °C was comparatively more due to the material softening and adhesion by intermolecular bonding. The worn debris collected during sliding at 350 °C turn into oxides which further behaves like a protective and lubricative film eliminating the chances of severe material loss. SEM was used to characterise the worn track and debris to identity the wear mechanism.

  8. Leg tissue composition and physico-chemical parameters of sheep meat fed annatto coproduct

    Directory of Open Access Journals (Sweden)

    Dorgival Morais de Lima Júnior

    2017-10-01

    Full Text Available Our objective was to evaluate leg tissue composition and physico-chemical quality parameters of sheep meat fed with increasing levels of annatto coproduct. 32 male uncastrated animals without a defined breed were randomized in four treatments (0, 100, 200 and 300 g kg-1 of annatto coproduct in the DM diet. After 78 days of confinement, the animals were slaughtered and body components were recorded. Reconstituted leg weight, total muscle weight, biceps weight and semitendinosus weight showed a negative linear behavior (P 0.05 were found for leg tissue composition (%, muscle:bone ratio, relative fat or leg muscle. Meat physico-chemical parameters (color, shear force, water retention capacity and cooking losses were not affected by the inclusion of the annatto coproduct in the diet. The annatto coproduct can be included in up to 300 g kg-1 of dietary dry matter without negative effects to the leg tissue composition (% and physical parameters of confined sheep meat.

  9. The complete information for phenomenal distributed parameter control of multicomponent chemical processes in gas, fluid and solid phase

    International Nuclear Information System (INIS)

    Niemiec, W.

    1985-01-01

    A constitutive mathematical model of distributed parameters of multicomponent chemical processes in gas, fluid and solid phase is utilized to the realization of phenomenal distributed parameter control of these processes. Original systems of partial differential constitutive state equations, in the following derivative forms /I/, /II/ and /III/ are solved in this paper from the point of view of information for phenomenal distributed parameter control of considered processes. Obtained in this way for multicomponent chemical processes in gas, fluid and solid phase: -dynamical working space-time characteristics/analytical solutions in working space-time of chemical reactors/, -dynamical phenomenal Green functions as working space-time transfer functions, -statical working space characteristics /analytical solutions in working space of chemical reactors/, -statical phenomenal Green functions as working space transfer functions, are applied, as information for realization of constitutive distributed parameter control of mass, energy and momentum aspects of above processes. Two cases are considered by existence of: A/sup o/ - initial conditions, B/sup o/ - initial and boundary conditions, for multicomponent chemical processes in gas, fluid and solid phase

  10. Fibrinogen and ceruloplasmin in plasma and milk from dairy cows with subclinical and clinical mastitis.

    Science.gov (United States)

    Tabrizi, A Davasaz; Batavani, R A; Rezaei, S Asri; Ahmadi, M

    2008-02-15

    The potential using of Acute Phase Proteins (APPs) in the assessment of mammary gland health was studied by examining the levels of Fibrinogen (Fb) and Ceruloplasmin (Cp) in plasma and milk from dairy cows with different grades of mastitis. Plasma samples were taken from jugular vein and milk samples were collected from quarters of cows with subclinical and clinical mastitis, as well as healthy controls. California Mastitis Test (CMT) were performed on each udder quarter of cows for detection of CMT2+ and CMT3+ quarters. CMT (0) and culture negative cases were considered healthy cows. Clinical mastitis, was graded as mild (clots in milk) or moderate (clots in milk and visible signs of inflammation in the mammary gland/s). The concentrations of Fb in the plasma of the cows with subclinical and clinical mastitis were higher than in the plasma of the healthy cows (p0.05), but differences between clinical and healthy groups were significant (pmastitis were higher than in the milk of the healthy cows (pmastitis in dairy cows.

  11. Global parameter optimization of a Mather-type plasma focus in the framework of the Gratton–Vargas two-dimensional snowplow model

    International Nuclear Information System (INIS)

    Auluck, S K H

    2014-01-01

    Dense plasma focus (DPF) is known to produce highly energetic ions, electrons and plasma environment which can be used for breeding short-lived isotopes, plasma nanotechnology and other material processing applications. Commercial utilization of DPF in such areas would need a design tool that can be deployed in an automatic search for the best possible device configuration for a given application. The recently revisited (Auluck 2013 Phys. Plasmas 20 112501) Gratton–Vargas (GV) two-dimensional analytical snowplow model of plasma focus provides a numerical formula for dynamic inductance of a Mather-type plasma focus fitted to thousands of automated computations, which enables the construction of such a design tool. This inductance formula is utilized in the present work to explore global optimization, based on first-principles optimality criteria, in a four-dimensional parameter-subspace of the zero-resistance GV model. The optimization process is shown to reproduce the empirically observed constancy of the drive parameter over eight decades in capacitor bank energy. The optimized geometry of plasma focus normalized to the anode radius is shown to be independent of voltage, while the optimized anode radius is shown to be related to capacitor bank inductance. (paper)

  12. Plasma for electrification of chemical industry : a case study on CO2 reduction

    NARCIS (Netherlands)

    Van Rooij, G.J.; Akse, H.N.; Bongers, W.A.; Van De Sanden, M.C.M.

    2018-01-01

    Significant growth of the share of (intermittent) renewable power in the chemical industry is imperative to meet increasingly stricter limits on CO2 exhaust that are being implemented within Europe. This paper aims to evaluate the potential of a plasma process that converts input CO2 into a pure

  13. HPLC determination of plasma dimethylarginines: method validation and preliminary clinical application.

    Science.gov (United States)

    Ivanova, Mariela; Artusi, Carlo; Boffa, Giovanni Maria; Zaninotto, Martina; Plebani, Mario

    2010-11-11

    Asymmetric dimethylarginine (ADMA) has been suggested as a possible marker of endothelial dysfunction, and interest in its use in clinical practice is increasing. However, the potential role of symmetric dimethylarginine (SDMA) as an endogenous marker of renal function, has been less widely investigated. The aims of the present study were therefore to determine reference values for dimethylarginines in plasma after method validation, and to ascertain ADMA plasma concentrations in patients with disorders characterized by endothelial dysfunction; a further end-point was to investigate the relationship between SDMA plasma concentrations and estimated GFR (eGFR) as well as plasmatic creatinine in patients with chronic kidney disease (CKD). HPLC with fluorescence detection was used for the determination of plasma dimethylarginines. To verify the clinical usefulness of ADMA and SDMA, values from 4 groups of patients at a high risk of cardiovascular complications as well renal dysfunction (chronic heart failure n=126; type II diabetes n=43; pulmonary arterial hypertension n=17; chronic kidney disease n=42) were evaluated, and compared with the reference values, obtained from 225 blood donors. The intra- and inter-assay CVs (peadiatric populations, for which the use of eGFR is not recommended. 2010 Elsevier B.V. All rights reserved.

  14. Expanding thermal plasma chemical vapour deposition of ZnO:Al layers for CIGS solar cells

    NARCIS (Netherlands)

    Sharma, K.; Williams, B.L.; Mittal, A.; Knoops, H.C.M.; Kniknie, B.J.; Bakker, N.J.; Kessels, W.M.M.; Schropp, R.E.I.; Creatore, M.

    2014-01-01

    Aluminium-doped zinc oxide (ZnO:Al) grown by expanding thermal plasma chemical vapour deposition (ETP-CVD) has demonstrated excellent electrical and optical properties, which make it an attractive candidate as a transparent conductive oxide for photovoltaic applications. However, when depositing

  15. Comparison of some effects of modification of a polylactide surface layer by chemical, plasma, and laser methods

    Science.gov (United States)

    Moraczewski, Krzysztof; Rytlewski, Piotr; Malinowski, Rafał; Żenkiewicz, Marian

    2015-08-01

    The article presents the results of studies and comparison of selected properties of the modified PLA surface layer. The modification was carried out with three methods. In the chemical method, a 0.25 M solution of sodium hydroxide in water and ethanol was utilized. In the plasma method, a 50 W generator was used, which produced plasma in the air atmosphere under reduced pressure. In the laser method, a pulsed ArF excimer laser with fluency of 60 mJ/cm2 was applied. Polylactide samples were examined by using the following techniques: scanning electron microscopy (SEM), atomic force microscopy (AFM), goniometry and X-ray photoelectron spectroscopy (XPS). Images of surfaces of the modified samples were recorded, contact angles were measured, and surface free energy was calculated. Qualitative and quantitative analyses of chemical composition of the PLA surface layer were performed as well. Based on the survey it was found that the best modification results are obtained using the plasma method.

  16. The value of swarm data for practical modeling of plasma devices

    Science.gov (United States)

    Napartovich, A. P.; Kochetov, I. V.

    2011-04-01

    The non-thermal plasma is a key component in gas lasers, waste gas cleaners, ozone generators, plasma igniters, flame holders, flow control in high-speed aerodynamics and other applications. The specific feature of the non-thermal plasma is its high sensitivity to variations in governing parameters (gas composition, pressure, pulse duration, E/N parameter). The reactivity of the plasma is due to the appearance of atoms and chemical radicals. For the efficient production of chemically active species high average electron energy is required, which is controlled by the balance of gain from the electric field and loss in inelastic collisions. In low-ionized plasma the electron energy distribution function is far from Maxwellian and must be found numerically for specified conditions. Numerical modeling of processes in plasma technologies requires vast databases on electron scattering cross sections to be available. The only reliable criterion for evaluations of validity of a set of cross sections for a particular species is a correct prediction of electron transport and kinetic coefficients measured in swarm experiments. This criterion is used traditionally to improve experimentally measured cross sections, as was suggested earlier by Phelps. The set of cross sections subjected to this procedure is called a self-consistent set. Nowadays, such reliable self-consistent sets are known for many species. Problems encountered in implementation of the fitting procedure and examples of its successful applications are described in the paper. .

  17. The value of swarm data for practical modeling of plasma devices

    International Nuclear Information System (INIS)

    Napartovich, A P; Kochetov, I V

    2011-01-01

    The non-thermal plasma is a key component in gas lasers, waste gas cleaners, ozone generators, plasma igniters, flame holders, flow control in high-speed aerodynamics and other applications. The specific feature of the non-thermal plasma is its high sensitivity to variations in governing parameters (gas composition, pressure, pulse duration, E/N parameter). The reactivity of the plasma is due to the appearance of atoms and chemical radicals. For the efficient production of chemically active species high average electron energy is required, which is controlled by the balance of gain from the electric field and loss in inelastic collisions. In low-ionized plasma the electron energy distribution function is far from Maxwellian and must be found numerically for specified conditions. Numerical modeling of processes in plasma technologies requires vast databases on electron scattering cross sections to be available. The only reliable criterion for evaluations of validity of a set of cross sections for a particular species is a correct prediction of electron transport and kinetic coefficients measured in swarm experiments. This criterion is used traditionally to improve experimentally measured cross sections, as was suggested earlier by Phelps. The set of cross sections subjected to this procedure is called a self-consistent set. Nowadays, such reliable self-consistent sets are known for many species. Problems encountered in implementation of the fitting procedure and examples of its successful applications are described in the paper.

  18. The Norwegian Plasma Fractionation Project--a 12 year clinical and economic success story.

    Science.gov (United States)

    Flesland, O; Seghatchian, J; Solheim, B G

    2003-02-01

    The establishment of the Norwegian Fractionation Project (Project) was of major importance in preserving national self-sufficiency when plasma, cryoprecipitate and small batch factor IX-concentrates were replaced by virus inactivated products in the last part of the 1980s. Fractionation was performed abroad by contract with Octapharma after tenders on the European market. All Norwegian blood banks (>50) participated in the Project. Total yearly production was 50-60 tons of mainly recovered plasma. From 1993 solvent detergent (SD) treated plasma has replaced other plasma for transfusion. The blood banks paid for the fractionation and/or viral inactivation process, while the plasma remained the property of the blood banks and the final products were returned to the blood banks. The Project sold surplus products to other Norwegian blood banks and the majority of the coagulation factor concentrates to The Institute of Haemophilia and Rikshospitalet University Hospital. Both plasma and blood bank quality was improved by the Project. Clinical experience with the products has been satisfactory and self-sufficiency has been achieved for all major plasma proteins and SD plasma, but a surplus exceeding 3 years consumption of albumin has accumulated due to decreasing clinical use.The Project has secured high yields of the fractionated products and the net income from the produced products is NOK 1115 (140 Euros or US dollars) per litre plasma. An increasing surplus of albumin and the possibility of significant sales abroad of currently not fractionated IVIgG, could lead to a reorganisation of the Project from that of a co-ordinator to a national plasma handling unit. This unit could buy the plasma from the blood banks and have the plasma fractionated by contract after tender, before selling the products back for cost recovery. The small blood banks could produce plasma for products for the Norwegian market, while surplus products from the larger blood banks which are

  19. Chemical characterization of materials by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Deb, S.B.; Nagar, B.K.; Saxena, M.K.; Ramakumar, K.L.

    2009-11-01

    An Inductively Coupled Plasma Mass Spectrometer was procured for trace elemental determination in diverse samples. Since its installation a number of analytical measurements have been carried out on different sample matrices. These include chemical quality control measurements of nuclear fuel and other materials such as uranium metal. Uranium peroxide, ADU, ThO 2 , UO 2 ; isotopic composition of B, Li; chemical characterization of simulated ThO 2 + 2%UO 2 fuel; sodium zirconium phosphate and trace metallic elements in zirconium; Antarctica rock samples and wet phosphoric acid. Necessary separation methodologies required for effective removal of matrix were indigenously developed. In addition, a rigorous analytical protocol, which includes various calibration methodologies such as mass calibration, response calibration, detector cross calibration and linearity check over the entire dynamic range of 109 required for quantitative determination of elements at trace and ultra trace level,, has been standardized. This report summarizes efforts of RACD that have been put in this direction for the application of ICP-MS for analytical measurements. (author)

  20. Quantitative detection of plasma-generated radicals in liquids by electron paramagnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Tresp, H; Hammer, M U; Winter, J; Reuter, S; Weltmann, K-D

    2013-01-01

    In this paper the qualitative and quantitative detection of oxygen radicals in liquids after plasma treatment with an atmospheric pressure argon plasma jet by electron paramagnetic resonance spectroscopy is investigated. Absolute values for · OH and O 2 ·- radical concentration and their net production rate in plasma-treated liquids are determined without the use of additional scavenging chemicals such as superoxide dismutase (SOD) or mannitol (D-MAN). The main oxygen-centred radical generation in PBS was found to originate from the superoxide radical. It is shown that hidden parameters such as the manufacturer of chemical components could have a big influence on the comparability and reproducibility of the results. Finally, the effect of a shielding gas device for the investigated plasma jet with a shielding gas composition of varying oxygen-to-nitrogen ratio on radical generation after plasma treatment of phosphate-buffered saline solution was investigated. (paper)

  1. Apparent Surface Free Energy of Polymer/Paper Composite Material Treated by Air Plasma

    Directory of Open Access Journals (Sweden)

    Konrad Terpiłowski

    2017-01-01

    Full Text Available Surface plasma treatment consists in changes of surface properties without changing internal properties. In this paper composite polymer/paper material is used for production of packaging in cosmetic industry. There are problems with bonding this material at the time of packaging production due to its properties. Composite surface was treated by air plasma for 1, 10, 20, and 30 s. The advancing and receding contact angles of water, formamide, and diiodomethane were measured using both treated and untreated samples. Apparent surface free energy was estimated using the hysteresis (CAH and Van Oss, Good, Chaudhury approaches (LWAB. Surface roughness was investigated using optical profilometry and identification of after plasma treatment emerging chemical groups was made by means of the XPS (X-ray photoelectron spectroscopy technique. After plasma treatment the values of contact angles decreased which is particularly evident for polar liquids. Apparent surface free energy increased compared to that of untreated samples. Changes of energy value are due to the electron-donor parameter of energy. This parameter increases as a result of adding polar groups at the time of surface plasma activation. Changes of surface properties are combination of increase of polar chemical functional groups, increase on the surface, and surface roughness increase.

  2. Do Urinary Cystine Parameters Predict Clinical Stone Activity?

    Science.gov (United States)

    Friedlander, Justin I; Antonelli, Jodi A; Canvasser, Noah E; Morgan, Monica S C; Mollengarden, Daniel; Best, Sara; Pearle, Margaret S

    2018-02-01

    An accurate urinary predictor of stone recurrence would be clinically advantageous for patients with cystinuria. A proprietary assay (Litholink, Chicago, Illinois) measures cystine capacity as a potentially more reliable estimate of stone forming propensity. The recommended capacity level to prevent stone formation, which is greater than 150 mg/l, has not been directly correlated with clinical stone activity. We investigated the relationship between urinary cystine parameters and clinical stone activity. We prospectively followed 48 patients with cystinuria using 24-hour urine collections and serial imaging, and recorded stone activity. We compared cystine urinary parameters at times of stone activity with those obtained during periods of stone quiescence. We then performed correlation and ROC analysis to evaluate the performance of cystine parameters to predict stone activity. During a median followup of 70.6 months (range 2.2 to 274.6) 85 stone events occurred which could be linked to a recent urine collection. Cystine capacity was significantly greater for quiescent urine than for stone event urine (mean ± SD 48 ± 107 vs -38 ± 163 mg/l, p stone activity (r = -0.29, p r = -0.88, p r = -0.87, p stone quiescence. Decreasing the cutoff to 90 mg/l or greater improved sensitivity to 25.2% while maintaining specificity at 90.9%. Our results suggest that the target for capacity should be lower than previously advised. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. An Atmospheric Pressure Chemical Ionization MS/MS Assay Using Online Extraction for the Analysis of 11 Cannabinoids and Metabolites in Human Plasma and Urine.

    Science.gov (United States)

    Klawitter, Jelena; Sempio, Cristina; Mörlein, Sophie; De Bloois, Erik; Klepacki, Jacek; Henthorn, Thomas; Leehey, Maureen A; Hoffenberg, Edward J; Knupp, Kelly; Wang, George S; Hopfer, Christian; Kinney, Greg; Bowler, Russell; Foreman, Nicholas; Galinkin, Jeffrey; Christians, Uwe; Klawitter, Jost

    2017-10-01

    Although, especially in the United States, there has been a recent surge of legalized cannabis for either recreational or medicinal purposes, surprisingly little is known about clinical dose-response relationships, pharmacodynamic and toxicodynamic effects of cannabinoids such as Δ9-tetrahydrocannabinol (THC). Even less is known about other active cannabinoids. To address this knowledge gap, an online extraction, high-performance liquid chromatography coupled with tandem mass spectrometry method for simultaneous quantification of 11 cannabinoids and metabolites including THC, 11-hydroxy-Δ9-tetrahydrocannabinol, 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid, 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide (THC-C-gluc), cannabinol, cannabidiol, cannabigerol, cannabidivarin, Δ9-tetrahydrocannabivarin (THCV), and 11-nor-9-carboxy-Δ9-tetrahydrocannabivarin (THCV-COOH) was developed and validated in human urine and plasma. In contrast to atmospheric pressure chemical ionization, electrospray ionization was associated with extensive ion suppression in plasma and urine samples. Thus, the atmospheric pressure chemical ionization assay was validated showing a lower limit of quantification ranging from 0.39 to 3.91 ng/mL depending on study compound and matrix. The upper limit of quantification was 400 ng/mL except for THC-C-gluc with an upper limit of quantification of 2000 ng/mL. The linearity was r > 0.99 for all analyzed calibration curves. Acceptance criteria for intrabatch and interbatch accuracy (85%-115%) and imprecision (<15%) were met for all compounds. In plasma, the only exceptions were THCV (75.3%-121.2% interbatch accuracy) and cannabidivarin (interbatch imprecision, 15.7%-17.2%). In urine, THCV did not meet predefined acceptance criteria for intrabatch accuracy. This assay allows for monitoring not only THC and its major metabolites but also major cannabinoids that are of interest for marijuana research and clinical practice.

  4. Controlled modification of octadecyltrichlorosilane self-assembled monolayer by CO2 plasma

    International Nuclear Information System (INIS)

    Delorme, Nicolas; Bardeau, Jean-Francois; Bulou, Alain; Poncin-Epaillard, Fabienne

    2006-01-01

    CO 2 -plasma is used to introduce functional groups on the uppermost surface of an alkoxy silane self-assembled monolayer (Sam). The structural and chemical modifications of the material surface were monitored by X-ray reflectometry, atomic force microscopy, X-ray photoelectrons spectroscopy and water contact angle measurements. Optimization of the plasma parameters is performed in order to achieve a maximum functionalization and to prevent degradation of the SAM. Finally, the ability of grafting organic compounds onto the plasma modified SAMS was demonstrated by the formation of an alkoxysilane bilayer

  5. Using atmospheric pressure plasma treatment for treating grey cotton fabric.

    Science.gov (United States)

    Kan, Chi-Wai; Lam, Chui-Fung; Chan, Chee-Kooi; Ng, Sun-Pui

    2014-02-15

    Conventional wet treatment, desizing, scouring and bleaching, for grey cotton fabric involves the use of high water, chemical and energy consumption which may not be considered as a clean process. This study aims to investigate the efficiency of the atmospheric pressure plasma (APP) treatment on treating grey cotton fabric when compared with the conventional wet treatment. Grey cotton fabrics were treated with different combinations of plasma parameters with helium and oxygen gases and also through conventional desizing, scouring and bleaching processes in order to obtain comparable results. The results obtained from wicking and water drop tests showed that wettability of grey cotton fabrics was greatly improved after plasma treatment and yielded better results than conventional desizing and scouring. The weight reduction of plasma treated grey cotton fabrics revealed that plasma treatment can help remove sizing materials and impurities. Chemical and morphological changes in plasma treated samples were analysed by FTIR and SEM, respectively. Finally, dyeability of the plasma treated and conventional wet treated grey cotton fabrics was compared and the results showed that similar dyeing results were obtained. This can prove that plasma treatment would be another choice for treating grey cotton fabrics. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Rocket measurements within a polar cap arc: Plasma, particle, and electric circuit parameters

    International Nuclear Information System (INIS)

    Weber, E.J.; Ballenthin, J.O.; Basu, S.; Carlson, H.C.; Hardy, D.A.; Maynard, N.C.; Smiddy, M.; Kelley, M.C.; Fleischman, J.R.; Sheehan, R.E.; Pfaff, R.F.; Rodriguez, P.

    1989-01-01

    An instrumented rocket payload was launched into a polar cap F layer aurora to investigate the energetic particle, plasma, and electric circuit parameters of a Sun-aligned arc. On-board instruments measured energetic electron flux, ion composition and density fluctuations, electron density and temperature, electron density fluctuations, and ac and dc electric fields. Real-time all-sky imaging photometer measurements of the location and motion of the aurora, were used to determine the proper geophysical situation for launch. Comparison of the in situ measurements with remote optical measurements shows that the arc was produced by fluxes of low-energy (< 1 keV) electrons. Field-aligned potentials in the arc inferred from the electron spectra had a maximum value of approximately 300 V, and from the spectral shape a parent population of preaccelerated electrons characteristic of the boundary plasma sheet or magnetosheath was inferred. Electric field components along and across the arc show sunward flow within the arc and duskward drift of the arc consistent with the drift direction and speed determined from optical imaging. Thus this arc is drifting duskward under the influence of the convection electric field. Three possible explanations for this (field-aligned currents, chemistry, and transport) are considered. Finally, ionospheric irregularity and electric field fluctuations indicate two different generation mechanisms on the dawnside and duskside of the arc. On the duskside, parameters are suggestive of an interchange process, while on the dawnside, fluctuation parameters are consistent with a velocity shear instability

  7. Apparatus and method for enhanced chemical processing in high pressure and atmospheric plasmas produced by high frequency electromagnetic waves

    Science.gov (United States)

    Efthimion, Philip C.; Helfritch, Dennis J.

    1989-11-28

    An apparatus and method for creating high temperature plasmas for enhanced chemical processing of gaseous fluids, toxic chemicals, and the like, at a wide range of pressures, especially at atmospheric and high pressures includes an electro-magnetic resonator cavity, preferably a reentrant cavity, and a wave guiding structure which connects an electro-magnetic source to the cavity. The cavity includes an intake port and an exhaust port, each having apertures in the conductive walls of the cavity sufficient for the intake of the gaseous fluids and for the discharge of the processed gaseous fluids. The apertures are sufficiently small to prevent the leakage of the electro-magnetic radiation from the cavity. Gaseous fluid flowing from the direction of the electro-magnetic source through the guiding wave structure and into the cavity acts on the plasma to push it away from the guiding wave structure and the electro-magnetic source. The gaseous fluid flow confines the high temperature plasma inside the cavity and allows complete chemical processing of the gaseous fluids at a wide range of pressures.

  8. Synthesis of electro-active manganese oxide thin films by plasma enhanced chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Merritt, Anna R. [Energetics Research Division, Naval Air Warfare Center Weapons Division, China Lake, CA 93555 (United States); Rajagopalan, Ramakrishnan [Department of Engineering, The Pennsylvania State University, Dubois, PA 15801 (United States); Materials Research Institute, The Pennsylvania State University, University Park, PA 16802 (United States); Carter, Joshua D. [Energetics Research Division, Naval Air Warfare Center Weapons Division, China Lake, CA 93555 (United States)

    2014-04-01

    The good stability, cyclability and high specific capacitance of manganese oxide (MnO{sub x}) has recently promoted a growing interest in utilizing MnO{sub x} in asymmetric supercapacitor electrodes. Several literature reports have indicated that thin film geometries of MnO{sub x} provide specific capacitances that are much higher than bulk MnO{sub x} powders. Plasma enhanced chemical vapor deposition (PECVD) is a versatile technique for the production of metal oxide thin films with high purity and controllable thickness. In this work, MnO{sub x} thin films deposited by PECVD from a methylcyclopentadienyl manganese tricarbonyl precursor are presented and the effect of processing conditions on the quality of MnO{sub x} films is described. The film purity and oxidation state of the MnO{sub x} films were studied by Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. Preliminary electrochemical testing of MnO{sub x} films deposited on carbon fiber electrodes in aqueous electrolytes indicates that the PECVD synthesized films are electrochemically active. - Highlights: • Plasma enhanced chemical vapor deposition of manganese oxide thin films. • Higher plasma power and chamber pressure increase deposition rate. • Manganese oxide thin films are electrochemically active. • Best electrochemical performance observed for pure film with low stress • Lower capacitance observed at higher scan rates despite thin film geometry.

  9. Physico-chemical study of coating plasma duplex alumina/hydroxyapatite for medical applications relation elaboration/structure/properties(dissolution/adherence/residual constraints); Etude physico-chimique de depots plasma duplex alumine/hydroxyapatite pour applications medicales relations elaboration/structure/proprietes (dissolution/adherence/contraintes residuelles)

    Energy Technology Data Exchange (ETDEWEB)

    Demonet, N

    1998-11-19

    The physico-chemical behavior of porous ceramics depositing is studied in order to use them to favour the biological fixing of hip prosthesis fixed without cement. Alumina depositing, hydroxyapatite depositing and duplex (the both together) have been realized by plasma projection on a substrate in Ti-6Al-V. Tests of dissolution have been made. An original method of sound followed by radioactive tracers has allowed to establish an order of phases degradation and to consider the kinetics of calcium ions in function of several parameters of tests. (N.C.)

  10. Evaluation of microbial contamination of canine plasma eyedropper bottles following clinical use in canine patients.

    Science.gov (United States)

    Strauss, Rachel A; Genschel, Ulrike; Allbaugh, Rachel A; Sebbag, Lionel; Ben-Shlomo, Gil

    2018-05-24

    To investigate microbial contamination of canine plasma eye drops when used clinically and to compare the effect of two different eyedropper bottles on contamination rate. Forty-six bottles containing plasma were randomly dispensed for use on 42 dogs with ulcerative keratitis. Of these, 23 were standard eyedropper bottles and 23 were Novelia ® bottles designed to prevent contamination. After use for up to 2 weeks, samples for bacterial culture were obtained from a drop of plasma, the bottle tip, the plasma inside the bottle, and the corneal surface. Fungal culture was performed from a drop of plasma. The overall microbial contamination rate was 17.4% (8/46 bottles); however, only one bottle had growth from the plasma inside the bottle. There was a lower contamination rate of Novelia ® bottles (3/23 = 13.0%) compared to standard bottles (5/23 = 21.7%), but this difference was not statistically significant (P = .57). There were also no significant differences in contamination rate of bottles used greater than 7 days compared to less than or equal to 7 days, or in bottles used greater than 4 times daily compared to 4 times daily or less. Three corneal samples (6.5%) had bacterial growth, but none matched contamination from the bottles. Novelia ® bottles may decrease contamination of plasma eye drops used clinically. However, while microbial contamination of plasma bottles was documented, no clinically relevant complications were observed. This study supports safe use of plasma eye drops for up to 2 weeks when refrigerated and dispensed from either Novelia ® or standard eyedropper bottles. © 2018 American College of Veterinary Ophthalmologists.

  11. Investigation of detached recombining deuterium plasma and carbon chemical erosion in the toroidal divertor simulator NAGDIS-T

    International Nuclear Information System (INIS)

    Yada, K.; Matsui, N.; Ohno, N.; Kajita, S.; Takamura, S.; Takagi, M.

    2009-01-01

    Detached deuterium recombining plasma has been generated in the toroidal divertor simulator. The electron temperature (0.1-0.4 eV) and density (∼10 18 m -3 ) in the detached plasmas were evaluated with a spectroscopic method using a series of deuterium Balmer line emission from highly excited levels and the Stark broadening of D(2-12). We have investigated the role of volume plasma recombination through Electron-Ion Recombination (EIR) and Molecular Activated Recombination (MAR) processes. Moreover, the carbon erosion in the detached deuterium plasma has been studied with a weight loss method. It is found that deuterium neutrals generated by EIR process could have strong influence on the carbon chemical erosion.

  12. Difference in chemical reactions in bulk plasma and sheath regions during surface modification of graphene oxide film using capacitively coupled NH{sub 3} plasma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung-Youp; Kim, Chan; Kim, Hong Tak, E-mail: zam89blue@gmail.com [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of)

    2015-09-14

    Reduced graphene oxide (r-GO) films were obtained from capacitively coupled NH{sub 3} plasma treatment of spin-coated graphene oxide (GO) films at room temperature. Variations were evaluated according to the two plasma treatment regions: the bulk plasma region (R{sub bulk}) and the sheath region (R{sub sheath}). Reduction and nitridation of the GO films began as soon as the NH{sub 3} plasma was exposed to both regions. However, with the increase in treatment time, the reduction and nitridation reactions differed in each region. In the R{sub bulk}, NH{sub 3} plasma ions reacted chemically with oxygen functional groups on the GO films, which was highly effective for reduction and nitridation. While in the R{sub sheath}, physical reactions by ion bombardment were dominant because plasma ions were accelerated by the strong electrical field. The accelerated plasma ions reacted not only with the oxygen functional groups but also with the broken carbon chains, which caused the removal of the GO films by the formation of hydrocarbon gas species. These results showed that reduction and nitridation in the R{sub bulk} using capacitively coupled NH{sub 3} plasma were very effective for modifying the properties of r-GO films for application as transparent conductive films.

  13. Performance Testing of Suspension Plasma Sprayed Thermal Barrier Coatings Produced with Varied Suspension Parameters

    Directory of Open Access Journals (Sweden)

    Nicholas Curry

    2015-07-01

    Full Text Available Suspension plasma spraying has become an emerging technology for the production of thermal barrier coatings for the gas turbine industry. Presently, though commercial systems for coating production are available, coatings remain in the development stage. Suitable suspension parameters for coating production remain an outstanding question and the influence of suspension properties on the final coatings is not well known. For this study, a number of suspensions were produced with varied solid loadings, powder size distributions and solvents. Suspensions were sprayed onto superalloy substrates coated with high velocity air fuel (HVAF -sprayed bond coats. Plasma spray parameters were selected to generate columnar structures based on previous experiments and were maintained at constant to discover the influence of the suspension behavior on coating microstructures. Testing of the produced thermal barrier coating (TBC systems has included thermal cyclic fatigue testing and thermal conductivity analysis. Pore size distribution has been characterized by mercury infiltration porosimetry. Results show a strong influence of suspension viscosity and surface tension on the microstructure of the produced coatings.

  14. Dielectric parameters of blood plasma of rats treated with cerium-144 and external irradiation

    International Nuclear Information System (INIS)

    Hadzhidekova, E.; Kiradzhiev, G.; Paskalev, Z.; Miloslavov, V.

    1988-01-01

    Investigation was carried out of the dielectric parameters of blood plasma of male Wistar rats treated with cerium 144 in doses of 370 kBq/animal and external gamma irradiation in doses of 200 cGy and 400 cGy. The radioactive cerium was introduced intraperitoneally 1 h after the external irradiation with dose rate of 1,6 cGy/sec. The permittivity ε, the time of relaxation τ and the coefficient of Debaye κ of plasma protein molecules were determined at the 1st, 3rd, 10th, 15th, and 30th days after treatement for frequence ranges of 1,4, 2,2, 3,6 and 6 MHz. At the same terms the content of cerium 144 was measured in the organs of predilectional accumulation of cerium. It was established that the treatment only with cerium lead to most essential changes of dielectric parameters at frequence of 3,6 MHz. The external irradiation didn't influence essentially the kinetics of absorbed cerium. In combination of both radiation factors the action of cerium was predominant

  15. Equation of state of partially-ionized dense plasmas

    International Nuclear Information System (INIS)

    Rogers, F.J.

    1989-01-01

    This paper describes methods for calculating the equation of state of partially-ionized dense plasmas. The term dense plasma is used rather than strongly coupled plasma, since it is possible that at plasma conditions such that only a few levels can be observed spectroscopically the plasma coupling parameters are not large. Due mainly to their importance in theoretical astrophysics, the properties of partially ionized plasmas have been of interest for a long while. More recently, this interest has intensified due to the development of methods for producing partially ionized plasmas in the laboratory. This has opened up large programs of experimental investigation and of practical application. In this paper we consider detailed statistical mechanical methods that explicitly treat the distribution over ionic species and their energy level structure. These detailed approaches are generally characterized as being in the ''chemical picture'' when a free energy expression is minimized or in the ''physical picture'' when the starting point is the grand canonical ensemble. 52 refs., 2 tabs

  16. One-step microwave plasma enhanced chemical vapor deposition (MW-PECVD) for transparent superhydrophobic surface

    Science.gov (United States)

    Thongrom, Sukrit; Tirawanichakul, Yutthana; Munsit, Nantakan; Deangngam, Chalongrat

    2018-02-01

    We demonstrate a rapid and environmental friendly fabrication technique to produce optically clear superhydrophobic surfaces using poly (dimethylsiloxane) (PDMS) as a sole coating material. The inert PDMS chain is transformed into a 3-D irregular solid network through microwave plasma enhanced chemical vapor deposition (MW-PECVD) process. Thanks to high electron density in the microwave-activated plasma, coating can be done in just a single step with rapid deposition rate, typically much shorter than 10 s. Deposited layers show excellent superhydrophobic properties with water contact angles of ∼170° and roll-off angles as small as ∼3°. The plasma-deposited films can be ultrathin with thicknesses under 400 nm, greatly diminishing the optical loss. Moreover, with appropriate coating conditions, the coating layer can even enhance the transmission over the entire visible spectrum due to a partial anti-reflection effect.

  17. Buffalo plasma fibronectin: a physico-chemical study.

    Science.gov (United States)

    Ahmed, N; Chandra, R; Raj, H G

    2001-12-01

    Plasma fibronectin (FN) of buffalo (Babulis babulis) was purified to apparent homogeneity, using gelatin-Sepharose and heparin-Sepharose affinity columns. It was found to have two subunits of molecular mass 246 kDa and 228 kDa, on SDS-gel. Its immunological cross-reactivity with anti-human plasma FN was confirmed by Western blotting. The amino acid composition was found to be similar to that of human and bovine plasma FNs. Buffalo plasma FN contained 2.23% neutral hexoses and 1.18% sialic acids. No titrable sulfhydryl group could be detected in the absence of denaturant. Reaction with DTNB indicated 3.4 sulfhydryl groups in the molecule, whereas BDC-OH titration gave a value of 3.8 -SH groups in buffalo plasma FN. Stoke's radius, intrinsic viscosity, diffusion coefficient and frictional ratio indicated that buffalo plasma FN did not have a compact globular conformation at physiological pH and ionic strength. Molecular dimensions (average length, 120 nm; molar mass to length ratio, 3950 nm(-1) and mean diameter, 2.4 nm) as revealed by rotary shadowing electron microscopy further supported the extended conformation of buffalo plasma FN. These results show that buffalo plasma FN has similar properties as that of human plasma FN.

  18. Assessment of physico-chemical parameters of Tsaeda Agam River in Mekelle City, Tigray, Ethiopia

    Directory of Open Access Journals (Sweden)

    K. Mezgebe

    2015-10-01

    Full Text Available The present work was conducted to assess the physico-chemical parameters of Tsada Agam River found in Mekelle, Tigray, Ethiopia and determine its suitability for domestic and irrigation purposes. Water samples were collected monthly for two consecutive months (February to March, 2013 at four sampling sites and analyzed for various physico-chemical parameters. The study indicated that the mean value of studied parameters, except electrical conductivity, total dissolved solids, turbidity, total alkalinity, calcium ion, sulphate ion, and total phosphorus of the river water samples were within the permissible limit of WHO for drinking water. The findings also showed the mean value of studied parameters, except sulphate ion concentration, were within the permissible limit of FAO for irrigation water. Therefore, the river water was found to be unfit for human consumption and was found to be safe and utilizable for irrigation purposes. If the quality management was properly maintained, the Tsaeda Agam River water could be utilized for a wide range of applications such as drinking and irrigation.DOI: http://dx.doi.org/10.4314/bcse.v29i3.5

  19. Consensus clinical recommendations for the management of plasma lipid disorders in the Middle East.

    Science.gov (United States)

    Al Sayed, Nasreen; Al Waili, Khalid; Alawadi, Fatheya; Al-Ghamdi, Saeed; Al Mahmeed, Wael; Al-Nouri, Fahad; Al Rukhaimi, Mona; Al-Rasadi, Khalid; Awan, Zuhier; Farghaly, Mohamed; Hassanein, Mohamed; Sabbour, Hani; Zubaid, Mohammad; Barter, Philip

    2016-12-15

    Plasma lipid disorders are key risk factors for the development of atherosclerotic cardiovascular disease (ASCVD) and are prevalent in the Middle East, with rates increasing in recent decades. Despite this, no region-specific guidelines for managing plasma lipids exist and there is a lack of use of guidelines developed in other regions. A multidisciplinary panel of regional experts was convened to develop consensus clinical recommendations for the management of plasma lipids in the Middle East. The panel considered existing international guidelines and regional clinical experience to develop recommendations. The panel's recommendations include plasma lipid screening, ASCVD risk calculation and treatment considerations. The panel recommend that plasma lipid levels should be measured in all at-risk patients and at regular intervals in all adults from the age of 20years. A scoring system should be used to calculate ASCVD risk that includes known lipid and non-lipid risk factors. Primary treatment targets include low-density lipoprotein cholesterol and non-high-density lipoprotein cholesterol. Lifestyle modifications should be first-line treatment for all patients; the first-line pharmacological treatment targeting plasma lipids in patients at moderate-to-high risk of ASCVD is statin therapy, with a number of adjunctive or second-line agents available. Guidance is also provided on the management of underlying conditions and special populations; of particular pertinence in the region are familial hypercholesterolaemia, diabetes and metabolic dyslipidaemia. These consensus clinical recommendations provide practicing clinicians with comprehensive, region-specific guidance to improve the detection and management of plasma lipid disorders in patients in the Middle East. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  20. Clinical application of determination of plasma intact parathyroid hormone content in kidney disease

    International Nuclear Information System (INIS)

    Zhu Mei; Wang Zhaohui; Zhou Xiaoli; Ren Chunling; Chen Huaqian

    2011-01-01

    Objective: To observe intact parathyroid hormone in kidney disease with clinical application. Methods: Plasma i-PTH level was measured in 46 patients with chronic renal insufficiency lose compensation stage, 39 patients with chronic renal failure, 35 patients with uremia. Besides, control group (n=41) was established. Results: Result shown that plasma i-PTH levels were experiment group and control group were obvious difference (P<0.01), among experiment group plasma i-PTH level was obvious difference (P<0.01). Conclusion: Results suggested along with renal function were worsen that plasma i-PTH level increasing gradually during renal insufficiency. (authors)

  1. Modulating Protein Adsorption on Oxygen Plasma Modified Polysiloxane Surfaces

    International Nuclear Information System (INIS)

    Marletta, G.

    2006-01-01

    In the present paper we report the study on the adsorption behaviour of three model globular proteins, Human Serum Albumin, Lactoferrin and Egg Chicken Lysozyme onto both unmodified surfaces of a silicon-based polymer and the corresponding plasma treated surfaces. In particular, thin films of hydrophobic polysiloxane (about 90 degree of static water contact angle, WCA) were converted by oxygen plasma treatment at reduced pressure into very hydrophilic phases of SiOx (WCA less than 5 degree). The kinetics of protein adsorption processes were investigated by QCM-D technique, while the chemical structure and topography of the protein adlayer have been studied by Angular resolved-XPS and AFM respectively. It turned out that Albumin and Lysozyme exhibited the opposite preferential adsorption respectively onto the hydrophobic and hydrophilic surfaces, while Lactoferrin did not exhibit significant differences. The observed protein behaviour are discussed both in terms of surface-dependent parameters, including surface free energy and chemical structure, and in terms of protein-dependent parameters, including charge as well as the average molecular orientation in the adlayers. Finally, some examples of differential adsorption behaviour of the investigated proteins are reported onto nanopatterned polysiloxane surfaces consisting of hydrophobic nanopores surrounded by hydrophilic (plasma-treated) matrix and the reverse

  2. Identification of goat milk powder by manufacturer using multiple chemical parameters.

    Science.gov (United States)

    McLeod, Rebecca J; Prosser, Colin G; Wakefield, Joshua W

    2016-02-01

    Concentrations of multiple elements and ratios of stable isotopes of carbon and nitrogen were measured and combined to create a chemical fingerprint of production batches of goat whole milk powder (WMP) produced by different manufacturers. Our objectives were to determine whether or not differences exist in the chemical fingerprint among samples of goat WMP produced at different sites, and assess temporal changes in the chemical fingerprint in product manufactured at one site. In total, 58 samples of goat WMP were analyzed by inductively coupled plasma-mass spectrometry as well as isotope ratio mass spectrometry and a suite of 13 elements (Li, Na, Mg, K, Ca, Mn, Cu, Zn, Rb, Sr, Mo, Cs, and Ba), δ(13)C, and δ(15)N selected to create the chemical fingerprint. Differences in the chemical fingerprint of samples between sites and over time were assessed using principal components analysis and canonical analysis of principal coordinates. Differences in the chemical fingerprints of samples between production sites provided a classification success rate (leave-one-out classification) of 98.1%, providing a basis for using the approach to test the authenticity of product manufactured at a site. Within one site, the chemical fingerprint of samples produced at the beginning of the production season differed from those produced in the middle and late season, driven predominantly by lower concentrations of Na, Mg, K, Mn, and Rb, and higher concentrations of Ba and Cu. This observed temporal variability highlights the importance of obtaining samples from throughout the season to ensure a representative chemical fingerprint is obtained for goat WMP from a single manufacturing site. The reconstitution and spray drying of samples from one manufacturer by the other manufacturer enabled the relative influence of the manufacturing process on the chemical fingerprint to be examined. It was found that such reprocessing altered the chemical fingerprint, although the degree of alteration

  3. A quantitative assay of cortisol in human plasma by high performance liquid chromatography using a selective chemically bonded stationary phase

    NARCIS (Netherlands)

    van den Berg, J.H.M.; Mol, C.R.; Deelder, R.S.; Thijssen, J.H.H.

    1977-01-01

    The extraction and subsequent liquid chromatographic analysis of human plasma samples for cortisol is described. Extraction and chromatography are optimized, resulting in a recovery for cortisol of 96% and a detection limit of 1 microgram cortisol in 100 ml plasma. The application of two chemically

  4. Simulated experiment for elimination of chemical and biological warfare agents by making use of microwave plasma torch

    International Nuclear Information System (INIS)

    Hong, Yong C.; Kim, Jeong H.; Uhm, Han S.

    2004-01-01

    The threat of chemical and biological warfare agents in a domestic terrorist attack and in military conflict is increasing worldwide. Elimination and decontamination of chemical and biological warfare (CBW) agents are immediately required after such an attack. Simulated experiment for elimination of CBW agents by making use of atmospheric-pressure microwave plasma torches is carried out. Elimination of biological warfare agents indicated by the vitrification or burnout of sewage sludge powders and decomposition of toluene gas as a chemical agent stimulant are presented. A detailed characterization for the elimination of the simulant chemicals using Fourier transform infrared and gas chromatography is also presented

  5. Simulated experiment for elimination of chemical and biological warfare agents by making use of microwave plasma torch

    Science.gov (United States)

    Hong, Yong C.; Kim, Jeong H.; Uhm, Han S.

    2004-02-01

    The threat of chemical and biological warfare agents in a domestic terrorist attack and in military conflict is increasing worldwide. Elimination and decontamination of chemical and biological warfare (CBW) agents are immediately required after such an attack. Simulated experiment for elimination of CBW agents by making use of atmospheric-pressure microwave plasma torches is carried out. Elimination of biological warfare agents indicated by the vitrification or burnout of sewage sludge powders and decomposition of toluene gas as a chemical agent stimulant are presented. A detailed characterization for the elimination of the simulant chemicals using Fourier transform infrared and gas chromatography is also presented.

  6. Growth of highly oriented carbon nanotubes by plasma-enhanced hot filament chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Z.P.; Xu, J.W.; Ren, Z.F.; Wang, J.H. [Materials Synthesis Laboratory, Departments of Physics and Chemistry, and Center for Advanced Photonic and Electronic Materials (CAPEM), State University of New York at Buffalo, Buffalo, New York 14260 (United States); Siegal, M.P.; Provencio, P.N. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States)

    1998-12-01

    Highly oriented, multiwalled carbon nanotubes were grown on polished polycrystalline and single crystal nickel substrates by plasma enhanced hot filament chemical vapor deposition at temperatures below 666 {degree}C. The carbon nanotubes range from 10 to 500 nm in diameter and 0.1 to 50 {mu}m in length depending on growth conditions. Acetylene is used as the carbon source for the growth of the carbon nanotubes and ammonia is used for dilution gas and catalysis. The plasma intensity, acetylene to ammonia gas ratio, and their flow rates, etc. affect the diameters and uniformity of the carbon nanotubes. {copyright} {ital 1998 American Institute of Physics.}

  7. Optical and passivating properties of hydrogenated amorphous silicon nitride deposited by plasma enhanced chemical vapour deposition for application on silicon solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Wight, Daniel Nilsen

    2008-07-01

    quality, etch rate. The response of these parameters to high temperature anneals were correlated with structural changes in the silicon nitride films as measured by using the hydrogen bond concentration. Plasma enhanced chemical vapour deposition allows continuous variation in nearly all deposition parameters. The parameters studied in this work are the gas flow ratios and excitation power. In both direct and remote deposition systems, the increase in deposition power density lead to higher activation of ammonia which in turn lead to augmented incorporation of nitrogen into the films and thus lower refractive index. For a direct system, the same parameter change lead to a drastic fall in passivation quality of Czochralski silicon attributed to an increase in ion bombardment as well as the general observation that as deposited passivation tends to increase with refractive index. Silicon nitride films with variations in refractive index were also made by varying the silane-to-ammonia gas flow ratio. This simple parameter adjustment makes plasma enhanced chemical vapour deposited silicon nitride applicable to double layer anti-reflective coatings simulated in this work. The films were found to have an etch rate in 5% hydrofluoric acid that decreased with increasing refractive index. This behaviour is attributed to the decreasing concentration of nitrogen-to-hydrogen bonds in the films. Such bonds at the surface of silicon nitride have been suggested to be involved in the main reaction mechanism when etching silicon nitride in hydrofluoric acid. Annealing the films lead to a drastic fall in etch rates and was linked to the release of hydrogen from the nitrogen-hydrogen bonds. (author). 115 refs., 35 figs., 6 tabs

  8. The Influences of H2Plasma Pretreatment on the Growth of Vertically Aligned Carbon Nanotubes by Microwave Plasma Chemical Vapor Deposition

    Directory of Open Access Journals (Sweden)

    Wen Hua-Chiang

    2008-01-01

    Full Text Available AbstractThe effects of H2flow rate during plasma pretreatment on synthesizing the multiwalled carbon nanotubes (MWCNTs by using the microwave plasma chemical vapor deposition are investigated in this study. A H2and CH4gas mixture with a 9:1 ratio was used as a precursor for the synthesis of MWCNT on Ni-coated TaN/Si(100 substrates. The structure and composition of Ni catalyst nanoparticles were investigated using scanning electron microscopy (SEM and transmission electron microscopy (TEM. The present findings showed that denser Ni catalyst nanoparticles and more vertically aligned MWCNTs could be effectively achieved at higher flow rates. From Raman results, we found that the intensity ratio of G and D bands (ID/IG decreases with an increasing flow rate. In addition, TEM results suggest that H2plasma pretreatment can effectively reduce the amorphous carbon and carbonaceous particles. As a result, the pretreatment plays a crucial role in modifying the obtained MWCNTs structures.

  9. Analysis of soil chemical parameters of an uncleaned crude oil spill ...

    African Journals Online (AJOL)

    Analysis of soil chemical parameters of an uncleaned crude oil spill site at Biara was carried out. Soil samples were collected at 0 -15 cm and 15 – 30 cm soil depths from both polluted and unpolluted sites for analysis. Significant increase in high total hydrocarbon content (1015±80.5 – 1150±90.1 mg/kg) in polluted site was ...

  10. Tungsten Deposition on Graphite using Plasma Enhanced Chemical Vapour Deposition

    International Nuclear Information System (INIS)

    Sharma, Uttam; Chauhan, Sachin S; Sharma, Jayshree; Sanyasi, A K; Ghosh, J; Choudhary, K K; Ghosh, S K

    2016-01-01

    The tokamak concept is the frontrunner for achieving controlled thermonuclear reaction on earth, an environment friendly way to solve future energy crisis. Although much progress has been made in controlling the heated fusion plasmas (temperature ∼ 150 million degrees) in tokamaks, technological issues related to plasma wall interaction topic still need focused attention. In future, reactor grade tokamak operational scenarios, the reactor wall and target plates are expected to experience a heat load of 10 MW/m 2 and even more during the unfortunate events of ELM's and disruptions. Tungsten remains a suitable choice for the wall and target plates. It can withstand high temperatures, its ductile to brittle temperature is fairly low and it has low sputtering yield and low fuel retention capabilities. However, it is difficult to machine tungsten and hence usages of tungsten coated surfaces are mostly desirable. To produce tungsten coated graphite tiles for the above-mentioned purpose, a coating reactor has been designed, developed and made operational at the SVITS, Indore. Tungsten coating on graphite has been attempted and successfully carried out by using radio frequency induced plasma enhanced chemical vapour deposition (rf -PECVD) for the first time in India. Tungsten hexa-fluoride has been used as a pre-cursor gas. Energy Dispersive X-ray spectroscopy (EDS) clearly showed the presence of tungsten coating on the graphite samples. This paper presents the details of successful operation and achievement of tungsten coating in the reactor at SVITS. (paper)

  11. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use

    OpenAIRE

    Robitaille, Line; Hoffer, L. John

    2016-01-01

    Background In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Methods Plasma vitamin C can be analyzed by high performance liquid chro...

  12. Chemical kinetics and relaxation of non-equilibrium air plasma generated by energetic photon and electron beams

    International Nuclear Information System (INIS)

    Maulois, Melissa; Ribière, Maxime; Eichwald, Olivier; Yousfi, Mohammed; Azaïs, Bruno

    2016-01-01

    The comprehension of electromagnetic perturbations of electronic devices, due to air plasma-induced electromagnetic field, requires a thorough study on air plasma. In the aim to understand the phenomena at the origin of the formation of non-equilibrium air plasma, we simulate, using a volume average chemical kinetics model (0D model), the time evolution of a non-equilibrium air plasma generated by an energetic X-ray flash. The simulation is undertaken in synthetic air (80% N_2 and 20% O_2) at ambient temperature and atmospheric pressure. When the X-ray flash crosses the gas, non-relativistic Compton electrons (low energy) and a relativistic Compton electron beam (high energy) are simultaneously generated and interact with the gas. The considered chemical kinetics scheme involves 26 influent species (electrons, positive ions, negative ions, and neutral atoms and molecules in their ground or metastable excited states) reacting following 164 selected reactions. The kinetics model describing the plasma chemistry was coupled to the conservation equation of the electron mean energy, in order to calculate at each time step of the non-equilibrium plasma evolution, the coefficients of reactions involving electrons while the energy of the heavy species (positive and negative ions and neutral atoms and molecules) is assumed remaining close to ambient temperature. It has been shown that it is the relativistic Compton electron beam directly created by the X-ray flash which is mainly responsible for the non-equilibrium plasma formation. Indeed, the low energy electrons (i.e., the non-relativistic ones) directly ejected from molecules by Compton collisions contribute to less than 1% on the creation of electrons in the plasma. In our simulation conditions, a non-equilibrium plasma with a low electron mean energy close to 1 eV and a concentration of charged species close to 10"1"3" cm"−"3 is formed a few nanoseconds after the peak of X-ray flash intensity. 200 ns after the

  13. Predictive Clinical Parameters and Glycemic Efficacy of Vildagliptin Treatment in Korean Subjects with Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Jin-Sun Chang

    2013-02-01

    Full Text Available BackgroundThe aims of this study are to investigate the glycemic efficacy and predictive parameters of vildagliptin therapy in Korean subjects with type 2 diabetes.MethodsIn this retrospective study, we retrieved data for subjects who were on twice-daily 50 mg vildagliptin for at least 6 months, and classified the subjects into five treatment groups. In three of the groups, we added vildagliptin to their existing medication regimen; in the other two groups, we replaced one of their existing medications with vildagliptin. We then analyzed the changes in glucose parameters and clinical characteristics.ResultsUltimately, 327 subjects were analyzed in this study. Vildagliptin significantly improved hemoglobin A1c (HbA1c levels over 6 months. The changes in HbA1c levels (ΔHbA1c at month 6 were -2.24% (P=0.000, -0.77% (P=0.000, -0.80% (P=0.001, -0.61% (P=0.000, and -0.34% (P=0.025 for groups 1, 2, 3, 4, and 5, respectively, with significance. We also found significant decrements in fasting plasma glucose levels in groups 1, 2, 3, and 4 (P<0.05. Of the variables, initial HbA1c levels (P=0.032 and history of sulfonylurea use (P=0.026 were independently associated with responsiveness to vildagliptin treatment.ConclusionVildagliptin was effective when it was used in subjects with poor glycemic control. It controlled fasting plasma glucose levels as well as sulfonylurea treatment in Korean type 2 diabetic subjects.

  14. Two approaches to the clinical dilemma of treating TTP with therapeutic plasma exchange in patients with a history of anaphylactic reactions to plasma.

    Science.gov (United States)

    Sidhu, Davinder; Snyder, Edward L; Tormey, Christopher A

    2017-06-01

    Thrombotic thrombocytopenic purpura (TTP) is a rare but serious disease caused by autoantibody-mediated deficiency in von Willebrand factor (VWF) cleaving protease, ADAMTS-13. The primary acute treatment is therapeutic plasma exchange (TPE). However, some patients can develop allergic/anaphylactic reactions to the replacement (i.e., donor) plasma over time. Two potential treatment strategies for patients with TTP who demonstrate severe allergic reactions to plasma used for exchange were examined. Two patients with TTP exacerbations who developed severe allergic reactions to donor plasma were identified. One patient's TPE was re-initiated with Octaplas, a lot-batched solvent and detergent treated, type-specific, pooled donor plasma product. The other patient was exchanged with primarily albumin, followed by slow incremental exposures to donor plasma to mitigate exposures and allergic risks. Both patients were assessed for anaphylaxis. Both treatment strategies were successful in preventing any further clinically significant allergic/anaphylactic reactions and facilitated both patients' TTP remissions. Based on our experience with two similar patients with TTP exacerbations and history of anaphylactic reactions to plasma during TPE, we have identified two possible treatment protocols to achieve remission in this clinical dilemma. Substituting Octaplas for standard plasma or, alternatively, using albumin with slowly increasing amounts of standard plasma may help to mitigate the risk of further anaphylactic adverse events. J. Clin. Apheresis 32:158-162, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Study on the effect of hydrogen addition on the variation of plasma parameters of argon-oxygen magnetron glow discharge for synthesis of TiO2 films

    Directory of Open Access Journals (Sweden)

    Partha Saikia

    2016-04-01

    Full Text Available We report the effect of hydrogen addition on plasma parameters of argon-oxygen magnetron glow discharge plasma in the synthesis of H-doped TiO2 films. The parameters of the hydrogen-added Ar/O2 plasma influence the properties and the structural phases of the deposited TiO2 film. Therefore, the variation of plasma parameters such as electron temperature (Te, electron density (ne, ion density (ni, degree of ionization of Ar and degree of dissociation of H2 as a function of hydrogen content in the discharge is studied. Langmuir probe and Optical emission spectroscopy are used to characterize the plasma. On the basis of the different reactions in the gas phase of the magnetron discharge, the variation of plasma parameters and sputtering rate are explained. It is observed that the electron and heavy ion density decline with gradual addition of hydrogen in the discharge. Hydrogen addition significantly changes the degree of ionization of Ar which influences the structural phases of the TiO2 film.

  16. Clinical parameters associated with periodontitis in untreated persons

    NARCIS (Netherlands)

    Lembariti, BS; Van't Hof, MA; Pilot, T; Van Palenstein-Helderman, WH

    The purpose of this study was to investigate the relationship between clinical parameters and periodontitis in a population receiving no regular prophylactic dental care. From a sample of 164 adult rural and urban Tanzanian subjects aged between 30 and 44 years, 16% were identified with

  17. Kinetic mechanism of molecular energy transfer and chemical reactions in low-temperature air-fuel plasmas.

    Science.gov (United States)

    Adamovich, Igor V; Li, Ting; Lempert, Walter R

    2015-08-13

    This work describes the kinetic mechanism of coupled molecular energy transfer and chemical reactions in low-temperature air, H2-air and hydrocarbon-air plasmas sustained by nanosecond pulse discharges (single-pulse or repetitive pulse burst). The model incorporates electron impact processes, state-specific N(2) vibrational energy transfer, reactions of excited electronic species of N(2), O(2), N and O, and 'conventional' chemical reactions (Konnov mechanism). Effects of diffusion and conduction heat transfer, energy coupled to the cathode layer and gasdynamic compression/expansion are incorporated as quasi-zero-dimensional corrections. The model is exercised using a combination of freeware (Bolsig+) and commercial software (ChemKin-Pro). The model predictions are validated using time-resolved measurements of temperature and N(2) vibrational level populations in nanosecond pulse discharges in air in plane-to-plane and sphere-to-sphere geometry; temperature and OH number density after nanosecond pulse burst discharges in lean H(2)-air, CH(4)-air and C(2)H(4)-air mixtures; and temperature after the nanosecond pulse discharge burst during plasma-assisted ignition of lean H2-mixtures, showing good agreement with the data. The model predictions for OH number density in lean C(3)H(8)-air mixtures differ from the experimental results, over-predicting its absolute value and failing to predict transient OH rise and decay after the discharge burst. The agreement with the data for C(3)H(8)-air is improved considerably if a different conventional hydrocarbon chemistry reaction set (LLNL methane-n-butane flame mechanism) is used. The results of mechanism validation demonstrate its applicability for analysis of plasma chemical oxidation and ignition of low-temperature H(2)-air, CH(4)-air and C(2)H(4)-air mixtures using nanosecond pulse discharges. Kinetic modelling of low-temperature plasma excited propane-air mixtures demonstrates the need for development of a more accurate

  18. Clinical significance of 2 h plasma concentrations of first-line anti-tuberculosis drugs

    DEFF Research Database (Denmark)

    Prahl, Julie B; Johansen, Isik S; Cohen, Arieh S

    2014-01-01

    OBJECTIVES: To study 2 h plasma concentrations of the first-line tuberculosis drugs isoniazid, rifampicin, ethambutol and pyrazinamide in a cohort of patients with tuberculosis in Denmark and to determine the relationship between the concentrations and the clinical outcome. METHODS: After 6......-207 days of treatment (median 34 days) 2 h blood samples were collected from 32 patients with active tuberculosis and from three patients receiving prophylactic treatment. Plasma concentrations were determined using LC-MS/MS. Normal ranges were obtained from the literature. Clinical charts were reviewed...... failure occurred more frequently when the concentrations of isoniazid and rifampicin were both below the normal ranges (P = 0.013) and even more frequently when they were below the median 2 h drug concentrations obtained in the study (P = 0.005). CONCLUSIONS: At 2 h, plasma concentrations of isoniazid...

  19. Optimization of enzyme parameters for fermentative production of biorenewable fuels and chemicals

    Directory of Open Access Journals (Sweden)

    Ping Liu

    2012-10-01

    Full Text Available Microbial biocatalysts such as Escherichia coli and Saccharomyces cerevisiae have been extensively subjected to Metabolic Engineering for the fermentative production of biorenewable fuels and chemicals. This often entails the introduction of new enzymes, deletion of unwanted enzymes and efforts to fine-tune enzyme abundance in order to attain the desired strain performance. Enzyme performance can be quantitatively described in terms of the Michaelis-Menten type parameters Km, turnover number kcat and Ki, which roughly describe the affinity of an enzyme for its substrate, the speed of a reaction and the enzyme sensitivity to inhibition by regulatory molecules. Here we describe examples of where knowledge of these parameters have been used to select, evolve or engineer enzymes for the desired performance and enabled increased production of biorenewable fuels and chemicals. Examples include production of ethanol, isobutanol, 1-butanol and tyrosine and furfural tolerance. The Michaelis-Menten parameters can also be used to judge the cofactor dependence of enzymes and quantify their preference for NADH or NADPH. Similarly, enzymes can be selected, evolved or engineered for the preferred cofactor preference. Examples of exporter engineering and selection are also discussed in the context of production of malate, valine and limonene.

  20. OPTIMIZATION OF ENZYME PARAMETERS FOR FERMENTATIVE PRODUCTION OF BIORENEWABLE FUELS AND CHEMICALS

    Directory of Open Access Journals (Sweden)

    Laura R. Jarboe

    2012-10-01

    Full Text Available Microbial biocatalysts such as Escherichia coli and Saccharomyces cerevisiae have been extensively subjected to Metabolic Engineering for the fermentative production of biorenewable fuels and chemicals. This often entails the introduction of new enzymes, deletion of unwanted enzymes and efforts to fine-tune enzyme abundance in order to attain the desired strain performance. Enzyme performance can be quantitatively described in terms of the Michaelis-Menten type parameters Km, turnover number kcat and Ki, which roughly describe the affinity of an enzyme for its substrate, the speed of a reaction and the enzyme sensitivity to inhibition by regulatory molecules. Here we describe examples of where knowledge of these parameters have been used to select, evolve or engineer enzymes for the desired performance and enabled increased production of biorenewable fuels and chemicals. Examples include production of ethanol, isobutanol, 1-butanol and tyrosine and furfural tolerance. The Michaelis-Menten parameters can also be used to judge the cofactor dependence of enzymes and quantify their preference for NADH or NADPH. Similarly, enzymes can be selected, evolved or engineered for the preferred cofactor preference. Examples of exporter engineering and selection are also discussed in the context of production of malate, valine and limonene.

  1. SITE-94. Chemical and physical transport parameters for SITE-94

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Karin [Chalmers Univ. of Technology, Goeteborg (Sweden). Technical Environmental Planning

    1996-02-01

    Important parameters are the interactions of radionuclides with solid surfaces, parameters describing the geometrical conditions like porosity, data on water composition (ionic strength, pH, redox conditions, complex formers etc) and data on the solids that may be of importance to the water and radionuclide chemistry. In this report some of these data of relevance for the Aespoe site are discussed. Based on a literature survey, sorption data as well as values for some other parameters have been selected for rock, fracture fillings and bentonite relevant to the chemical conditions in and around a repository at Aespoe. A comparison to data used for earlier, site-specific as well as general, safety assessments of underground repositories has been performed. The data are recommendations for modelling of radionuclide release from a hypothetical high level waste repository at Aespoe. Since the data to a large extent are not based on experimental measurements, more accurate predictions may be expected if more experimental data are available. Before such studies are performed for a specific site, a variational analysis in order to evaluate the importance of the single parameters is recommended. After such a study, the key parameters may be investigated in detail and the modelling can be expected to be more accurate what concerns influence of single parameters. However, the uncertainty in conceptual areas like how to model accurately the long term hydrology of the site etc still remains. 32 refs.

  2. Photon production in an expanding and chemically equilibrating gluon-enriched plasma

    International Nuclear Information System (INIS)

    Kaempfer, B.; Technische Univ. Dresden; Pavlenko, O.P.; AN Ukrainskoj SSR, Kiev

    1993-12-01

    Photon production in a longitudinally and transversely expanding gluon plasma with initially little quark admixture is considered. Chemical equilibration of quarks and gluons is followed by rate equations. The yields of hard photons with E ≥ 2 GeV are insensitive to chemical equilibration and depend mainly on the initial thermalized state. Medium-energy photons with E ∼ 1 GeV are more frequently produced in case of faster equilibration, despite of faster cooling. For an assumed fast equilibration we follow the evolution of matter through mixed and hadron phases. The transverse momentum kick, due to transverse expansion, of photons from hadron matter is shown to be reduced for an equation of state with reduced latent heat. The photon yield in the region E > 1 GeV from deconfined matter dominates for conditions, estimated to be achieved at RHIC, in case of a weakly first-order confinement transition. (orig.)

  3. Plasma sheath dynamics and parameters in focus and defocus conditions. Vol. 2

    International Nuclear Information System (INIS)

    Masoud, M.M.; Soliman, H.M.; El-Aragi, G.M.

    1996-01-01

    The study deals with the effect of the inner electrode polarity on the dynamic behaviour and parameters of plasma sheath in a coaxial discharge. The experimental investigations presented here were carried out in a coaxial plasma focus discharge device of mather geometry. It consisted of coaxial stainless steel hollow cylindrical electrodes with inner electrode 18.2 cm length and outer-electrode 31.5 cm length. The diameter of the inner and outer electrodes are 3.2 cm and 6.6 cm, respectively. The two electrodes are separated by a teflon disc at the breech. The outer electrode muzzle is connected to stainless steel expansion chamber of 23 cm length and 17 cm diameter. The discharge takes place in hydrogen gas with a base pressure of 1 torr. The experiments were conducted with 10 kV bank voltage, which corresponds to 100 K A peak discharge current. By using a double electric probe, It was found that the plasma electron density was higher near the negative electrode. Investigations using a miniature rogovsky coil have shown that, the radial and azimuthal current density increased with radial distance from negative electrode to positive electrode. The shape and the axial velocity of plasma sheath were measured using a magnetic probe. The experimental results indicate that, the plasma is thick near the negative electrode, in both cases of the outer or the inner electrode. Also it has been found that the axial plasma sheath velocity reaches its maximum value at the muzzle for positive and negative inner electrode. The magnitude of maximum axial velocity reaches 1.7 x 10 60 cm/s for positive inner electrode and decreased by 25% for negative inner electrode further investigations revealed that on interchanging the polarity from normal operation (positive inner electrode), it was found that with negative inner electrode the soft x-ray emission intensity dropped by three orders of magnitude from that with positive inner electrode. 9 figs

  4. Plasma sheath dynamics and parameters in focus and defocus conditions. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Masoud, M M; Soliman, H M; El-Aragi, G M [Plasma Physics and Nuclear Fusion Department, Nuclear Research Centre, Atomic Energy Aurhority, Cairo (Egypt)

    1996-03-01

    The study deals with the effect of the inner electrode polarity on the dynamic behaviour and parameters of plasma sheath in a coaxial discharge. The experimental investigations presented here were carried out in a coaxial plasma focus discharge device of mather geometry. It consisted of coaxial stainless steel hollow cylindrical electrodes with inner electrode 18.2 cm length and outer-electrode 31.5 cm length. The diameter of the inner and outer electrodes are 3.2 cm and 6.6 cm, respectively. The two electrodes are separated by a teflon disc at the breech. The outer electrode muzzle is connected to stainless steel expansion chamber of 23 cm length and 17 cm diameter. The discharge takes place in hydrogen gas with a base pressure of 1 torr. The experiments were conducted with 10 kV bank voltage, which corresponds to 100 K A peak discharge current. By using a double electric probe, It was found that the plasma electron density was higher near the negative electrode. Investigations using a miniature rogovsky coil have shown that, the radial and azimuthal current density increased with radial distance from negative electrode to positive electrode. The shape and the axial velocity of plasma sheath were measured using a magnetic probe. The experimental results indicate that, the plasma is thick near the negative electrode, in both cases of the outer or the inner electrode. Also it has been found that the axial plasma sheath velocity reaches its maximum value at the muzzle for positive and negative inner electrode. The magnitude of maximum axial velocity reaches 1.7 x 10{sup 60} cm/s for positive inner electrode and decreased by 25% for negative inner electrode further investigations revealed that on interchanging the polarity from normal operation (positive inner electrode), it was found that with negative inner electrode the soft x-ray emission intensity dropped by three orders of magnitude from that with positive inner electrode. 9 figs.

  5. Expanding Thermal Plasma Chemical Vapour Deposition of ZnO:Al Layers for CIGS Solar Cells

    Directory of Open Access Journals (Sweden)

    K. Sharma

    2014-01-01

    Full Text Available Aluminium-doped zinc oxide (ZnO:Al grown by expanding thermal plasma chemical vapour deposition (ETP-CVD has demonstrated excellent electrical and optical properties, which make it an attractive candidate as a transparent conductive oxide for photovoltaic applications. However, when depositing ZnO:Al on CIGS solar cell stacks, one should be aware that high substrate temperature processing (i.e., >200°C can damage the crucial underlying layers/interfaces (such as CIGS/CdS and CdS/i-ZnO. In this paper, the potential of adopting ETP-CVD ZnO:Al in CIGS solar cells is assessed: the effect of substrate temperature during film deposition on both the electrical properties of the ZnO:Al and the eventual performance of the CIGS solar cells was investigated. For ZnO:Al films grown using the high thermal budget (HTB condition, lower resistivities, ρ, were achievable (~5 × 10−4 Ω·cm than those grown using the low thermal budget (LTB conditions (~2 × 10−3 Ω·cm, whereas higher CIGS conversion efficiencies were obtained for the LTB condition (up to 10.9% than for the HTB condition (up to 9.0%. Whereas such temperature-dependence of CIGS device parameters has previously been linked with chemical migration between individual layers, we demonstrate that in this case it is primarily attributed to the prevalence of shunt currents.

  6. Temporal evolution of the spectral lines emission and temperatures in laser induced plasmas through characteristic parameters

    International Nuclear Information System (INIS)

    Bredice, F.; Pacheco Martinez, P.; Sánchez-Aké, C.; Villagrán-Muniz, M.

    2015-01-01

    In this work, we propose an extended Boltzmann plot method to determine the usefulness of spectral lines for plasma parameter calculations. Based on the assumption that transient plasmas are under ideal conditions during an specific interval of time Δt, (i.e. thin, homogeneous and in local thermodynamic equilibrium (LTE)), the associated Boltzmann plots describe a surface in the space defined by the coordinates X = Energy, Y = Time and Z = ln (λ jl I j /g j A jl ), where I j is the integrated intensity of the spectral line, g j is the statistical weight of the level j, λ jl is the wavelength of the considered line and A jl is its transition rate. In order to express the Boltzmann plot surface in terms of a reduced set of constants B i , and δ i , we developed as a power series of time, the logarithm of I n (t)/I n (t 0 ), where I n (t) is the integrated intensity of any spectral line at time t, and I n (t 0 ) at initial time. Moreover, the temporal evolution of the intensity of any spectral line and consequently the temperature of the plasma can be also expressed with these constants. The comparison of the temporal evolution of the line intensity calculated using these constants with their experimental values, can be used as a criterion for selecting useful lines in plasma analysis. Furthermore, this method can also be applied to determine self-absorption or enhancement of the spectral lines, to evaluate a possible departure of LTE, and to check or estimate the upper level energy value of any spectral line. An advantage of this method is that the value of these constants does not depend on the spectral response of the detection system, the uncertainty of the transition rates belonging to the analyzed spectral lines or any other time-independent parameters. In order to prove our method, we determined the constants B i and δ i and therefore the Boltzmann plot surface from the temporal evolution of carbon lines obtained from a plasma generated by a Nd:YAG laser

  7. Research on the discharge characteristics for water tree in crosslinked polyethylene cable based on plasma-chemical model

    Science.gov (United States)

    Fan, Yang; Qi, Yang; Bing, Gao; Rong, Xia; Yanjie, Le; Iroegbu, Paul Ikechukwu

    2018-03-01

    Water tree is the predominant defect in high-voltage crosslinked polyethylene cables. The microscopic mechanism in the discharge process is not fully understood; hence, a drawback is created towards an effective method to evaluate the insulation status. In order to investigate the growth of water tree, a plasma-chemical model is developed. The dynamic characteristics of the discharge process including voltage waveform, current waveform, electron density, electric potential, and electric field intensity are analyzed. Our results show that the distorted electric field is the predominant contributing factor of electron avalanche formation, which inevitably leads to the formation of pulse current. In addition, it is found that characteristic parameters such as the pulse width and pulse number have a great relevance to the length of water tree. Accordingly, the growth of water tree can be divided into the initial stage, development stage, and pre-breakdown stage, which provides a reference for evaluating the deteriorated stages of crosslinked polyethylene cables.

  8. The physical and chemical properties of plasma treated ultra-high-molecular-weight polyethylene fibers

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Teodoru, Steluta; Hansen, Charles M.

    2011-01-01

    A uniform and smooth transfer of stresses across the polymer matrix/fiber interface is enhanced when adhesion between the matrix and fiber surface is optimized. In the absence of covalent bonds matching the Hansen solubility (cohesion) parameters (HSP) of the fiber surface with the HSP of a matrix...... at 18.0, 1.2, and 1.4, all in MPa½. The dispersion parameter has been lowered somewhat by the plasma treatment, while the polar and hydrogen bonding parameters are much higher. The HSP methodology predicts enhanced adhesion is possible by skillful use of anhydride and nitrile functional groups in matrix...

  9. Tailoring of the morphology and chemical composition of thin organosilane microwave plasma polymer layers on metal substrates

    Energy Technology Data Exchange (ETDEWEB)

    Grundmeier, G.; Thiemann, P.; Carpentier, J.; Shirtcliffe, N.; Stratmann, M

    2004-01-01

    The growth of thin microwave organosilicon plasma polymers on model zinc surfaces was investigated as a function of the film thickness and the oxygen partial pressure during film deposition. The evolution of the topology of the film was studied by atomic force microscopy (AFM). The nano- and micro-roughness was investigated at the inner and the outer surfaces of the plasma polymers. A special etching procedure was developed to reveal the underside of the plasma polymer and thereby its inner surface. Rough films contained voids at the interface, which reduced the polymer/metal contact area. The increase in oxygen partial pressure led to a smoother film growth with a perfect imitation of the substrate topography at the interface. The chemical structure of the films was determined by infrared reflection absorption spectroscopy (IRRAS), X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectroscopy (ToF-SIMS). ToF-SIMS at the outer and the inner surface of the plasma polymers showed that the density of methylsilyl groups increases in the outer surface layer of the plasma polymer and depends on the oxygen partial pressure. The chemical composition of the films could be altered to pure SiO{sub 2} without changing the morphology by using oxygen-plasma post-treatment. This was proved by means of IRRAS and AFM. Chemistry and topology of the films were correlated with the apparent water contact angle. It was found that a linear relationship exists between the nanoscopic roughness of the plasma polymer and the static contact angle of water. Superposition of a nanoscopic roughness of the metal surface and the nanoscopic roughness of methylsilyl-rich films led to ultra-hydrophobic films with water contact angles up to 160 deg.

  10. High-performance metabolic profiling of plasma from seven mammalian species for simultaneous environmental chemical surveillance and bioeffect monitoring.

    Science.gov (United States)

    Park, Youngja H; Lee, Kichun; Soltow, Quinlyn A; Strobel, Frederick H; Brigham, Kenneth L; Parker, Richard E; Wilson, Mark E; Sutliff, Roy L; Mansfield, Keith G; Wachtman, Lynn M; Ziegler, Thomas R; Jones, Dean P

    2012-05-16

    High-performance metabolic profiling (HPMP) by Fourier-transform mass spectrometry coupled to liquid chromatography gives relative quantification of thousands of chemicals in biologic samples but has had little development for use in toxicology research. In principle, the approach could be useful to detect complex metabolic response patterns to toxicologic exposures and to detect unusual abundances or patterns of potentially toxic chemicals. As an initial study to develop these possible uses, we applied HPMP and bioinformatics analysis to plasma of humans, rhesus macaques, marmosets, pigs, sheep, rats and mice to determine: (1) whether more chemicals are detected in humans living in a less controlled environment than captive species and (2) whether a subset of plasma chemicals with similar inter-species and intra-species variation could be identified for use in comparative toxicology. Results show that the number of chemicals detected was similar in humans (3221) and other species (range 2537-3373). Metabolite patterns were most similar within species and separated samples according to family and order. A total of 1485 chemicals were common to all species; 37% of these matched chemicals in human metabolomic databases and included chemicals in 137 out of 146 human metabolic pathways. Probability-based modularity clustering separated 644 chemicals, including many endogenous metabolites, with inter-species variation similar to intra-species variation. The remaining chemicals had greater inter-species variation and included environmental chemicals as well as GSH and methionine. Together, the data suggest that HPMP provides a platform that can be useful within human populations and controlled animal studies to simultaneously evaluate environmental exposures and biological responses to such exposures. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. Diagnostic utility of clinical and biochemical parameters in ...

    African Journals Online (AJOL)

    Diagnostic utility of clinical and biochemical parameters in pancreatic head malignancy patients with normal carbohydrate antigen 19-9 levels. Xiaoli Jin1, Yulian Wu2. 1. Department of Surgery, Sir Run Run Shaw Hospital College of Medicine, Zhejiang University, 3 Qingchun. Road East, Hangzhou, Zhejiang Province ...

  12. Chemical composition and fermentative parameters of heart of palm waste produced from Alexander Palm ensiled with chemical additives

    Directory of Open Access Journals (Sweden)

    Geraldo Fábio Viana Bayão

    Full Text Available ABSTRACT The objective of this study was to evaluate the chemical composition and the fermentative parameters of heart of palm waste produced from Alexander Palm, ensiled with chemical additives. Treatments consisted of silage of the sheath with or without calcium oxide. In the silage without calcium oxide, we evaluated the control silage (without additive and the silage enriched with 5.0 g kg−1 urea (urea. In the silage with calcium oxide, we evaluated the silage enriched with 5.0 g kg−1 calcium oxide (control and the silage enriched with 5.0 g kg−1 urea and 5.0 g kg−1 calcium oxide (urea. Experimental silos were distributed in a completely randomized design in a 2 × 2 factorial arrangement (inclusion or lack of lime × inclusion or lack of urea, with four replicates. Crude protein concentration was greater in the silages that received urea, whereas in the case of neutral detergent fiber and acid detergent fiber, the lowest levels were found in the control silage. Control silage had the lowest pH (3.75 and the silages that received lime displayed the lowest lactic acid content. Effluent losses were greater in the control silage and in the silage with lime (56.1 kg t−1 and 58.4 kg t−1, respectively. Silages prepared with waste from heart of palm production and enriched only with urea showed a better chemical composition and improved fermentation parameter estimates. We recommend the use of this waste only with additives that can improve the chemical characteristics of the forage. Without additives, unwanted fermentation processes may occur and compromise the quality of the silage.

  13. Effects of the addition of blood plasma proteins on physico-chemical properties of emulsion-type pork sausage during cold storage.

    Science.gov (United States)

    Kim, Sungho; Jin, Sangkeun; Choi, Jungseok

    2017-10-01

    Most slaughter blood is discarded, resulting in problems related to costs for wastewater disposal and environmental pollution. However, animal blood contains various proteins such as albumin, globulin and globin and can be used as a natural emulsifier, stabiliser and colour additive. Thus, this study was carried out to investigate the effect of blood plasma proteins on the physico-chemical properties of emulsion-type pork sausages stored at 4°C over 5 weeks. The emulsion-type pork sausages with plasma powders had higher pH than the other treatments during week 5, and higher shear force than the control (P binder for the production of excellent meat products compared to other binders. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  14. Plasma drug concentrations and clinical effects of a peripheral alpha-2-adrenoceptor antagonist, MK-467, in horses sedated with detomidine.

    Science.gov (United States)

    Vainionpää, Mari H; Raekallio, Marja R; Pakkanen, Soile A E; Ranta-Panula, Ville; Rinne, Valtteri M; Scheinin, Mika; Vainio, Outi M

    2013-05-01

    To investigate plasma drug concentrations and the effect of MK-467 (L-659'066) on sedation, heart rate and gut motility in horses sedated with intravenous (IV) detomidine. Experimental randomized blinded crossover study. Six healthy horses. Detomidine (10 μg kg(-1) IV) was administered alone (DET) and in combination with MK-467 (250 μg kg(-1) IV; DET + MK). The level of sedation and intestinal sounds were scored. Heart rate (HR) and central venous pressure (CVP) were measured. Blood was collected to determine plasma drug concentrations. Repeated measures anova was used for HR, CVP and intestinal sounds, and the Student's t-test for pairwise comparisons between treatments for the area under the time-sedation curve (AUCsed ) and pharmacokinetic parameters. Significance was set at p Detomidine-induced intestinal hypomotility was prevented by MK-467. AUCsed was significantly higher with DET than DET + MK, but maximal sedations scores did not differ significantly between treatments. MK-467 lowered the AUC of the plasma concentration of detomidine, and increased its volume of distribution and clearance. MK-467 prevented detomidine induced bradycardia and intestinal hypomotility. MK-467 did not affect the clinical quality of detomidine-induced sedation, but the duration of the effect was reduced, which may have been caused by the effects of MK-467 on the plasma concentration of detomidine. MK-467 may be useful clinically in the prevention of certain peripheral side effects of detomidine in horses. © 2013 The Authors. Veterinary Anaesthesia and Analgesia © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  15. Comparative X-ray photoelectron spectroscopy study of plasma enhanced chemical vapor deposition and micro pressure chemical vapor deposition of phosphorus silicate glass layers after rapid thermal annealing

    International Nuclear Information System (INIS)

    Beshkov, G.; Krastev, V.; Gogova, D.; Talik, E.; Adamies, M.

    2008-01-01

    In this paper the bonding state of Phosphorus Silicate Glass (PSG) layers obtained by two different technological approaches, i.e. in two types of reactors: Plasma Enhanced Chemical Vapor Deposition (PECVD) and Micro Pressure Chemical Vapor Deposition (MPCVD) are investigated employing XPS and AES. The PSG layers are deposited at 380 0 C and 420 0 C in corresponding reactors. XPS and AES analyses show that Si2p peak recorded from PECVD layers are not as expected at their position characteristics of silicon dioxide but instead they are at the characteristic of elemental silicon. Plasma enhancement during deposition leads to less oxidized and more inhomogeneous layer. After rapid thermal annealing the Si2p peak is situated at position characteristic of silicon dioxide. (authors)

  16. Kinetic modeling in pre-clinical positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kuntner, Claudia [AIT Austrian Institute of Technology GmbH, Seibersdorf (Austria). Biomedical Systems, Health and Environment Dept.

    2014-07-01

    Pre-clinical positron emission tomography (PET) has evolved in the last few years from pure visualization of radiotracer uptake and distribution towards quantification of the physiological parameters. For reliable and reproducible quantification the kinetic modeling methods used to obtain relevant parameters of radiotracer tissue interaction are important. Here we present different kinetic modeling techniques with a focus on compartmental models including plasma input models and reference tissue input models. The experimental challenges of deriving the plasma input function in rodents and the effect of anesthesia are discussed. Finally, in vivo application of kinetic modeling in various areas of pre-clinical research is presented and compared to human data.

  17. INTERACTION OF LASER RADIATION WITH MATTER. LASER PLASMA: Spectroscopic investigation of thermodynamic parameters of a plasma plume formed by the action of cw CO2 laser radiation on a metal substrate

    Science.gov (United States)

    Vasil'chenko, Zh V.; Azharonok, V. V.; Filatova, I. I.; Shimanovich, V. D.; Golubev, V. S.; Zabelin, A. M.

    1996-09-01

    Emission spectroscopy methods were used in an investigation of thermodynamic parameters of a surface plasma formed by the action of cw CO2 laser radiation of (2-5)×106 W cm-2 intensity on stainless steel in a protective He or Ar atmosphere. The spatiotemporal structure and pulsation characteristics of the plasma plume were used to determine the fields of the plasma electron density and temperature.

  18. The effect of processing parameters on plasma sprayed beryllium for fusion applications

    International Nuclear Information System (INIS)

    Castro, R.G.; Stanek, P.W.; Jacobson, L.A.; Cowgill, D.F.; Snead, L.L.

    1993-01-01

    Plasma spraying is being investigated as a potential coating technique for applying thin (0.1--5mm) layers of beryllium on plasma facing surfaces of blanket modules in ITER and also as an in-situ repair technique for repairing eroded beryllium surfaces in high heat flux divertor regions. High density spray deposits (>98% of theoretical density) of beryllium will be required in order to maximize the thermal conductivity of the beryllium coatings. A preliminary investigation was done to determine the effect of various processing parameters (particle size, particle morphology, secondary gas additions and reduced chamber pressure) on the as-deposited density of beryllium. The deposits were made using spherical beryllium feedstock powder which was produced by centrifugal atomization at Los Alamos National Laboratory (LANL). Improvements in the as-deposited densities and deposit efficiencies of the beryllium spray deposits will be discussed along with the corresponding thermal conductivity and outgassing behavior of these deposits

  19. The effect of processing parameters on plasma sprayed beryllium for fusion applications

    International Nuclear Information System (INIS)

    Castro, R.G.; Stanek, P.W.; Jacobson, L.W.; Cowgill, D.F.

    1993-01-01

    Plasma spraying is being investigated as a potential coating technique for applying thin (0.1-5mm) layers of beryllium on plasma facing surfaces of blanket modules in ITER and also as an in-situ repair technique for repairing eroded beryllium surfaces in high heat flux divertor regions. High density spray deposits (>98% of theoretical density) of beryllium will be required in order to maximize the thermal conductivity of the beryllium coatings. A preliminary investigation was done to determine the effect of various processing parameters (particle size, particle morphology, secondary gas additions and reduced chamber pressure) on the as-deposited density of beryllium. The deposits were made using spherical beryllium feedstock powder which was produced by centrifugal atomization at Los Alamos National Laboratory (LANL). Improvements in the as-deposited densities and deposit efficiencies of the beryllium spray deposits will be discussed along with the corresponding thermal conductivity and outgassing behavior of these deposits. (orig.)

  20. Effect of plasma composition on nanocrystalline diamond layers deposited by a microwave linear antenna plasma-enhanced chemical vapour deposition system

    Czech Academy of Sciences Publication Activity Database

    Taylor, Andrew; Ashcheulov, Petr; Čada, Martin; Fekete, Ladislav; Hubík, Pavel; Klimša, Ladislav; Olejníček, Jiří; Remeš, Zdeněk; Jirka, Ivan; Janíček, P.; Bedel-Pereira, E.; Kopeček, Jaromír; Mistrík, J.; Mortet, Vincent

    2015-01-01

    Roč. 212, č. 11 (2015), s. 2418-2423 ISSN 1862-6300 R&D Projects: GA ČR GA13-31783S; GA MŠk LO1409 Grant - others:FUNBIO(XE) CZ.2.16/3.1.00/21568 Institutional support: RVO:68378271 ; RVO:61388955 Keywords : diamond * electrical conductivity * nanocrystalline materials * optical emission spectroscopy * plasma enhanced chemical vapour deposition * SiC Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.648, year: 2015

  1. Low pressure plasma spray deposition of W-Ni-Fe alloy

    International Nuclear Information System (INIS)

    Mutasim, Z.Z.; Smith, R.W.

    1991-01-01

    The production of net shape refractory metal structural preforms are increasing in importance in chemical processing, defense and aerospace applications. Conventional methods become limited for refractory metal processing due to the high melting temperatures and fabrication difficulties. Plasma spray forming, a high temperature process, has been shown to be capable of refractory metal powder consolidation in net shape products. The research reported here has evaluated this method for the deposition of heavy tungsten alloys. Plasma Melted Rapidly Solidified (PMRS) W 8%Ni-2%Fe refractory metal powders were spray formed using vacuum plasma spray (VPS) process and produced 99% dense, fine grain and homogeneous microstructures. In this paper plasma operating parameters (plasma arc gas type and flowrate plasma gun nozzle size and spray distance) were studied and their effects on deposit's density and microstructure are reported

  2. plasmatis Center for Innovation Competence: Controlling reactive component output of atmospheric pressure plasmas in plasma medicine

    Science.gov (United States)

    Reuter, Stephan

    2012-10-01

    The novel approach of using plasmas in order to alter the local chemistry of cells and cell environment presents a significant development in biomedical applications. The plasmatis center for innovation competence at the INP Greifswald e.V. performs fundamental research in plasma medicine in two interdisciplinary research groups. The aim of our plasma physics research group ``Extracellular Effects'' is (a) quantitative space and time resolved diagnostics and modelling of plasmas and liquids to determine distribution and composition of reactive species (b) to control the plasma and apply differing plasma source concepts in order to produce a tailored output of reactive components and design the chemical composition of the liquids/cellular environment and (c) to identify and understand the interaction mechanisms of plasmas with liquids and biological systems. Methods to characterize the plasma generated reactive species from plasma-, gas- and liquid phase and their biological effects will be presented. The diagnostic spectrum ranges from absorption/emission/laser spectroscopy and molecular beam mass spectrometry to electron paramagnetic resonance spectroscopy and cell biological diagnostic techniques. Concluding, a presentation will be given of the comprehensive approach to plasma medicine in Greifswald where the applied and clinical research of the Campus PlasmaMed association is combined with the fundamental research at plasmatis center.

  3. Effects of magnesium on erythrocyte sodium-lithium countertransport and some of plasma biochemical parameters in rabbit

    Directory of Open Access Journals (Sweden)

    Samad Akbarzadeh

    2009-02-01

    Full Text Available Background: Magnesium acts as an essential cofactor for the activity of many enzymes. It regulates the work of cardiovascular system. The activity of sodium–lithium countertransport (SLC and the concentrations of plasma biochemical parameters such as VLDL, LDL-cholesterol, HDL-cholesterol, sodium, potassium, urea and creatinine are changed in cardiovascular diseases. The aim of this study was to determine the effects of magnesium on SLC activity and some of the plasma biochemical parameters. Methods: New Zealand white rabbits (weighed 1350 ± 50g were chosen for these experiments. This study was conducted through two in vitro and in vivo techniques. Through in vitro method, the effects of different concentrations of magnesium on SLC activity were investigated. In order to conduct in vivo method, the rabbits were divided into two groups (5 /group. One group was treated by MgSo4 (40 mg/kg body weight through peritoneum for two weeks. For the second group, deionized water was used. The activity of SLC and mentioned biochemical parameters were determined. Results: The results of both in vitro and in vivo studies showed that magnesium can significantly decrease the SLC activity and also causes an increase in Km and decreased Vmax/Km of the system and plasma concentrations of VLDL, LDL-cholesterol, total cholesterol and triglycerides were significantly decreased. Conclusion: Magnesium may cause a reduction in blood pressure through decreasing the SLC activity and affecting the concentrations of VLDL, LDL-cholesterol, total cholesterol and triglycerides and so improvement the cardiovascular diseases.

  4. Microcavity Plasma Devices and Arrays Fabricated in Semiconductor, Ceramic, or Metal/polymer Structures: A New Realm of Plasma Physics and Photonics Applications

    International Nuclear Information System (INIS)

    Eden, J. G.

    2005-01-01

    Micro discharge, or microcavity plasma, is the broad term that has come to be associated with an emerging class of glow discharge devices in which the characteristic spatial dimension of the plasma is nominally ) dia. Si wafers and operated in the rare gases and Ar/N2 gas mixtures. Also, photodetection in the ultraviolet, visible and near-infrared with microplasma devices has been observed by interfacing a low temperature plasma with a semiconductor. Carbon nanotubes grown directly within the microcavity of microplasma devices improve all key performance parameters of the device, and nanoporous Al2O3 grown onto Al by wet chemical processing yields microplasma devices of exceptional stability and lifetime. The opportunities such structures offer for accessing new avenues in plasma physics and photonics will be discussed. (Author)

  5. Clinical value of plasma endothelin levels in children with cardiovascular diseases

    International Nuclear Information System (INIS)

    Chen Nianfa; Duan Yongqiang

    2009-01-01

    To explore the clinical value of plasma endothelin (ET-1) levels in children with cardiovascular diseases, 77 children with heart failure, obesity, hyperlipemia, fatty liver and hypertension were divided into 5 experimental groups and 21 health children with same age and gender as control group. The plasma levels of ET-1 in these children were tested by RIA. The results showed that plasma levels of ET-1 in 5 experimental groups were 112.8 ± 34.1ng/L, 57.8 ± 19.1ng/L,64.5 ± 25.3ng/L, 74.9 ± 28.4ng/L and 60.7 ± 21.6ng/L, respectively. The ET-1 levels in 5 groups were significantly higher than that in control group (P<0.01). The results indicate the higher plasma ET-1 levels in children are related with cardiovascular diseases, and it is useful in the diagnosis of children cardiovascular diseases. (authors)

  6. Toxicity challenges in environmental chemicals: Prediction of ...

    Science.gov (United States)

    Physiologically based pharmacokinetic (PBPK) models bridge the gap between in vitro assays and in vivo effects by accounting for the adsorption, distribution, metabolism, and excretion of xenobiotics, which is especially useful in the assessment of human toxicity. Quantitative structure-activity relationships (QSAR) serve as a vital tool for the high-throughput prediction of chemical-specific PBPK parameters, such as the fraction of a chemical unbound by plasma protein (Fub). The presented work explores the merit of utilizing experimental pharmaceutical Fub data for the construction of a universal QSAR model, in order to compensate for the limited range of high-quality experimental Fub data for environmentally relevant chemicals, such as pollutants, pesticides, and consumer products. Independent QSAR models were constructed with three machine-learning algorithms, k nearest neighbors (kNN), random forest (RF), and support vector machine (SVM) regression, from a large pharmaceutical training set (~1000) and assessed with independent test sets of pharmaceuticals (~200) and environmentally relevant chemicals in the ToxCast program (~400). Small descriptor sets yielded the optimal balance of model complexity and performance, providing insight into the biochemical factors of plasma protein binding, while preventing over fitting to the training set. Overlaps in chemical space between pharmaceutical and environmental compounds were considered through applicability of do

  7. Plasma Total Antioxidant Capacity and Cardiometabolic Risk in Non-Obese and Clinically Healthy Young Adults.

    Science.gov (United States)

    Costa, Jamille Oliveira; Vásquez, Cecília M Passos; Santana, Gleiciane de Jesus; Silva, Natanael de Jesus; Braz, Juciene de Matos; Jesus, Amélia M Ribeiro de; Silva, Danielle Góes da; Cunha, Luana Celina Seraphim; Barbosa, Kiriaque Barra Ferreira

    2017-07-10

    The oxidative biomarkers play an important role in the genesis of cardiometabolic risk-related processes. To investigate the total antioxidant capacity of plasma and its association with cardiometabolic risk in non-obese and clinically healthy young adults. University students of the state of Sergipe, Brazil, aged between 18 and 25 years, were recruited for this study from May of 2013 and October of 2014. Anthropometric, clinical and biochemical parameters were measured and analyzed using protocols which were previously standardized and described in the literature. The measurement of plasma total antioxidant capacity was based on the ability that all the antioxidants present in the sample (plasma) have to inhibit the oxidation of the oxidizable substrate ABTS (2,2`- Azino-di-[3-ethylbenzthiazoline sulphonate]) to ABTS•+ by metmyoglobin. Approximately 25% of the sample presented more than one component of cardiometabolic risk. Low HDL-cholesterol was the most prevalent component. Compared to absence of components, the subjects with at least one component presented greater body weight and waist circumference, higher levels of diastolic blood pressure and fasting glucose, greater total cholesterol/HDL-c ratio, and lower levels of HDL-c (p literatura. A medida da capacidade antioxidante total do plasma baseou-se na capacidade de todos os antioxidantes presentes na amostra (plasma) em inibir a oxidação do substrato oxidável ABTS (2,2-Azino-bis-(3-etilbenzotiazolina-6-sulfonato) a ABTS•+ pela metamioglobina. Aproximadamente 25% da amostra apresentaram mais de um componente do risco cardiometabólico. Valores baixos de HDL foram o componente mais prevalente. Em comparação à ausência de componentes, os indivíduos com pelo menos um componente apresentou valores mais altos de peso corporal, circunferência da cintura, pressão sanguínea diastólica, glicemia de jejum e razão colesterol total/HDL-c, e valores mais baixos de HDL-c (p < 0,05). A glicemia de jejum

  8. Plasma spray technology process parameters and applications

    International Nuclear Information System (INIS)

    Sreekumar, K.P.; Karthikeyan, J.; Ananthapadmanabhan, P.V.; Venkatramani, N.; Chatterjee, U.K.

    1991-01-01

    The current trend in the structural design philosophy is based on the use of substrate with the necessary mechanical properties and a thin coating to exhibit surface properties. Plasma spray process is a versatile surface coating technique which finds extensive application in meeting advance technologies. This report describes the plasma spray technique and its use in developing coatings for various applications. The spray system is desribed in detail including the different variables such as power input to the torch, gas flow rate, powder properties, powder injection, etc. and their interrelation in deciding the quality of the coating. A brief write-up on the various plasma spray coatings developed for different applications is also included. (author). 15 refs., 15 figs., 2 tabs

  9. Plasma Immersion Ion Implantation in Radio Frequency Plasma

    International Nuclear Information System (INIS)

    Bora, B.; Bhuyan, H.; Wyndham, E.

    2013-01-01

    Plasma immersion ion implantation (PIII) has attracted wide interests since it emulates conventional ion-beam ion implantation (IBII) in niche applications. For instance, the technique has very high throughput, the implantation time is independent of the sample size, and samples with an irregular shape can be implanted without complex beam scanning or sample manipulation. For uniform ion implantation and deposition on to different substrates, like silicon, stainless steel etc., a capacitive coupled Radio frequency (RF), 13.6 MHz, plasma is used. During the PIII process, the physical parameters which are expected to play crucial rule in the deposition process like RF power, Negative pulse voltage and pulse duration, gas type and gas mixture, gas flow rates and the implantation dose are studied. The ion dose is calculated by dynamic sheath model and the plasma parameters are calculated from the V-I characteristic and power balance equation by homogeneous model of rf plasma discharge considering Ohmic as well as Stochastic heating. The correlations between the yield of the implantation process and the physical parameters as well as plasma parameters are discussed. (author)

  10. Decontamination of chemical and biological warfare (CBW) agents using an atmospheric pressure plasma jet (APPJ)

    Science.gov (United States)

    Herrmann, H. W.; Henins, I.; Park, J.; Selwyn, G. S.

    1999-05-01

    The atmospheric pressure plasma jet (APPJ) [A. Schütze et al., IEEE Trans. Plasma Sci. 26, 1685 (1998)] is a nonthermal, high pressure, uniform glow plasma discharge that produces a high velocity effluent stream of highly reactive chemical species. The discharge operates on a feedstock gas (e.g., He/O2/H2O), which flows between an outer, grounded, cylindrical electrode and an inner, coaxial electrode powered at 13.56 MHz rf. While passing through the plasma, the feedgas becomes excited, dissociated or ionized by electron impact. Once the gas exits the discharge volume, ions and electrons are rapidly lost by recombination, but the fast-flowing effluent still contains neutral metastable species (e.g., O2*, He*) and radicals (e.g., O, OH). This reactive effluent has been shown to be an effective neutralizer of surrogates for anthrax spores and mustard blister agent. Unlike conventional wet decontamination methods, the plasma effluent does not cause corrosion and it does not destroy wiring, electronics, or most plastics, making it highly suitable for decontamination of sensitive equipment and interior spaces. Furthermore, the reactive species in the effluent rapidly degrade into harmless products leaving no lingering residue or harmful by-products.

  11. Laser-pulsed Plasma Chemistry: Laser-initiated Plasma Oxidation Of Niobium

    OpenAIRE

    Marks R.F.; Pollak R.A.; Avouris Ph.; Lin C.T.; Thefaine Y.J.

    1983-01-01

    We report the first observation of the chemical modification of a solid surface exposed to an ambient gas plasma initiated by the interaction of laser radiation with the same surface. A new technique, which we designate laser-pulsed plasma chemistry (LPPC), is proposed for activating heterogeneous chemical reactions at solid surfaces in a gaseous ambient by means of a plasma initiated by laser radiation. Results for niobium metal in one atmosphere oxygen demonstrate single-pulse, self-limitin...

  12. Furosemide/Fludrocortisone Test and Clinical Parameters to Diagnose Incomplete Distal Renal Tubular Acidosis in Kidney Stone Formers.

    Science.gov (United States)

    Dhayat, Nasser A; Gradwell, Michael W; Pathare, Ganesh; Anderegg, Manuel; Schneider, Lisa; Luethi, David; Mattmann, Cedric; Moe, Orson W; Vogt, Bruno; Fuster, Daniel G

    2017-09-07

    Incomplete distal renal tubular acidosis is a well known cause of calcareous nephrolithiasis but the prevalence is unknown, mostly due to lack of accepted diagnostic tests and criteria. The ammonium chloride test is considered as gold standard for the diagnosis of incomplete distal renal tubular acidosis, but the furosemide/fludrocortisone test was recently proposed as an alternative. Because of the lack of rigorous comparative studies, the validity of the furosemide/fludrocortisone test in stone formers remains unknown. In addition, the performance of conventional, nonprovocative parameters in predicting incomplete distal renal tubular acidosis has not been studied. We conducted a prospective study in an unselected cohort of 170 stone formers that underwent sequential ammonium chloride and furosemide/fludrocortisone testing. Using the ammonium chloride test as gold standard, the prevalence of incomplete distal renal tubular acidosis was 8%. Sensitivity and specificity of the furosemide/fludrocortisone test were 77% and 85%, respectively, yielding a positive predictive value of 30% and a negative predictive value of 98%. Testing of several nonprovocative clinical parameters in the prediction of incomplete distal renal tubular acidosis revealed fasting morning urinary pH and plasma potassium as the most discriminative parameters. The combination of a fasting morning urinary threshold pH 3.8 mEq/L yielded a negative predictive value of 98% with a sensitivity of 85% and a specificity of 77% for the diagnosis of incomplete distal renal tubular acidosis. The furosemide/fludrocortisone test can be used for incomplete distal renal tubular acidosis screening in stone formers, but an abnormal furosemide/fludrocortisone test result needs confirmation by ammonium chloride testing. Our data furthermore indicate that incomplete distal renal tubular acidosis can reliably be excluded in stone formers by use of nonprovocative clinical parameters. Copyright © 2017 by the American

  13. Parallel artificial liquid membrane extraction of acidic drugs from human plasma

    DEFF Research Database (Denmark)

    Roldan-Pijuan, Mercedes; Pedersen-Bjergaard, Stig; Gjelstad, Astrid

    2015-01-01

    The new sample preparation concept “Parallel artificial liquid membrane extraction (PALME)” was evaluated for extraction of the acidic drugs ketoprofen, fenoprofen, diclofenac, flurbiprofen, ibuprofen, and gemfibrozil from human plasma samples. Plasma samples (250 μL) were loaded into individual......-performance liquid chromatography-ultraviolet detection of the individual acceptor solutions. Important PALME parameters including the chemical composition of the liquid membrane, extraction time, and sample pH were optimized, and the extraction performance was evaluated. Except for flurbiprofen, exhaustive...

  14. Sterilization and Decontamination of Surfaces Contaminated With Biological and Chemical Warfare Agents Using Atmospheric Pressure Plasma Discharges

    National Research Council Canada - National Science Library

    Garate, Eusebio

    1999-01-01

    ... based on the application of an atmospheric pressure plasma. We used both a DC corona and dielectric barrier discharge for the sterilization tests which were conducted on a variety of substrates including metals and chemically resistant fabrics...

  15. Gene expression responses of HeLa cells to chemical species generated by an atmospheric plasma flow

    International Nuclear Information System (INIS)

    Yokoyama, Mayo; Johkura, Kohei; Sato, Takehiko

    2014-01-01

    Highlights: • Response of HeLa cells to a plasma-irradiated medium was revealed by DNA microarray. • Gene expression pattern was basically different from that in a H 2 O 2 -added medium. • Prominently up-/down-regulated genes were partly shared by the two media. • Gene ontology analysis showed both similar and different responses in the two media. • Candidate genes involved in response to ROS were detected in each medium. - Abstract: Plasma irradiation generates many factors able to affect the cellular condition, and this feature has been studied for its application in the field of medicine. We previously reported that hydrogen peroxide (H 2 O 2 ) was the major cause of HeLa cell death among the chemical species generated by high level irradiation of a culture medium by atmospheric plasma. To assess the effect of plasma-induced factors on the response of live cells, HeLa cells were exposed to a medium irradiated by a non-lethal plasma flow level, and their gene expression was broadly analyzed by DNA microarray in comparison with that in a corresponding concentration of 51 μM H 2 O 2 . As a result, though the cell viability was sufficiently maintained at more than 90% in both cases, the plasma-medium had a greater impact on it than the H 2 O 2 -medium. Hierarchical clustering analysis revealed fundamentally different cellular responses between these two media. A larger population of genes was upregulated in the plasma-medium, whereas genes were downregulated in the H 2 O 2 -medium. However, a part of the genes that showed prominent differential expression was shared by them, including an immediate early gene ID2. In gene ontology analysis of upregulated genes, the plasma-medium showed more diverse ontologies than the H 2 O 2 -medium, whereas ontologies such as “response to stimulus” were common, and several genes corresponded to “response to reactive oxygen species.” Genes of AP-1 proteins, e.g., JUN and FOS, were detected and notably elevated in

  16. Gene expression responses of HeLa cells to chemical species generated by an atmospheric plasma flow

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Mayo, E-mail: yokoyama@plasma.ifs.tohoku.ac.jp [Institute of Fluid Science, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Johkura, Kohei, E-mail: kohei@shinshu-u.ac.jp [Department of Histology and Embryology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto 390-8621 (Japan); Sato, Takehiko, E-mail: sato@ifs.tohoku.ac.jp [Institute of Fluid Science, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan)

    2014-08-08

    Highlights: • Response of HeLa cells to a plasma-irradiated medium was revealed by DNA microarray. • Gene expression pattern was basically different from that in a H{sub 2}O{sub 2}-added medium. • Prominently up-/down-regulated genes were partly shared by the two media. • Gene ontology analysis showed both similar and different responses in the two media. • Candidate genes involved in response to ROS were detected in each medium. - Abstract: Plasma irradiation generates many factors able to affect the cellular condition, and this feature has been studied for its application in the field of medicine. We previously reported that hydrogen peroxide (H{sub 2}O{sub 2}) was the major cause of HeLa cell death among the chemical species generated by high level irradiation of a culture medium by atmospheric plasma. To assess the effect of plasma-induced factors on the response of live cells, HeLa cells were exposed to a medium irradiated by a non-lethal plasma flow level, and their gene expression was broadly analyzed by DNA microarray in comparison with that in a corresponding concentration of 51 μM H{sub 2}O{sub 2}. As a result, though the cell viability was sufficiently maintained at more than 90% in both cases, the plasma-medium had a greater impact on it than the H{sub 2}O{sub 2}-medium. Hierarchical clustering analysis revealed fundamentally different cellular responses between these two media. A larger population of genes was upregulated in the plasma-medium, whereas genes were downregulated in the H{sub 2}O{sub 2}-medium. However, a part of the genes that showed prominent differential expression was shared by them, including an immediate early gene ID2. In gene ontology analysis of upregulated genes, the plasma-medium showed more diverse ontologies than the H{sub 2}O{sub 2}-medium, whereas ontologies such as “response to stimulus” were common, and several genes corresponded to “response to reactive oxygen species.” Genes of AP-1 proteins, e.g., JUN

  17. Impact of gas puffing location on density control and plasma parameters in TJ-II

    International Nuclear Information System (INIS)

    Tabares, F.L.; Garcia-Cortes, I.; Estrada, T.; Tafalla, D.; Hidalgo, A.; Ferreira, J.A.; Pastor, I.; Herranz, J.; Ascasibar, E.

    2005-01-01

    Under pure Electron Cyclotron Resonance Heating (ECRH) conditions in TJ-II plasmas (P<300 kW, 53.2 GHz, 2nd harmonic X-mode, power density < 25 W/m''3), plasma start-up and good density control are obtained only by the proper combination of wall conditions and gas puffing characteristics. Such a control is particularly critical for the optimisation of the NBI power transfer to the target plasmas. The relatively low cut-off limit is easily reached due not only to the unfavourable wall/puffing-fuelling ratio but also due to the steep density profiles developed during the Enhanced Particle Confinement (EPC) modes. These modes are triggered by the gas puffing waveform, and they cannot be achieved for high iota magnetic configurations in TJ-II. Comparative experiments under metallic and boronised wall conditions have shown that the sensitivity of the EPC modes to the puffing rate is at least partially related to the energy balance at the plasma periphery under central heating scenarios. In this work, the impact of gas-fuelling location on the plasma parameters and density control is described. For that purpose, three different fuelling locations have been investigated; broad distribution from a side ports, localized injection from long tubes at different poloidal positions and highly localized injection through a movable limiter. Edge density and temperature profiles from a broad set of diagnostics (atomic beams, reflectometry, Thompson Scattering ECE, etc...) are analysed and compared. It has been found that preventing from transition to the EPC mode is achieved by using slow puffing rates, while neutral penetration into the plasma core can be enhanced for highly localized gas sources. Wall inventory, however, has been found to pl ay a dominant role in the fuelling of the plasma under most conditions. (author)

  18. Visualizing the influence of the process parameters on the keyhole dimensions in plasma arc welding

    International Nuclear Information System (INIS)

    Liu, Z M; Wu, C S; Chen, M A

    2012-01-01

    The keyhole status and its dimensions are critical information determining both the process quality and weld quality in plasma arc welding (PAW). It is of great significance to measure the keyhole shape and size and to correlate them with the main process parameters. In this study, a low-cost vision system is developed to visualize the keyhole at the backside of the test-pieces in PAW. Three stages of keyhole evolution, i.e. initial blind stage (non-penetrated keyhole), unstable stage with momentarily disappeared keyhole and quasi-steady open keyhole stage (fully-penetrated keyhole), are measured in real-time during the PAW tests on stainless steel test-pieces of thickness 8 mm. Based on the captured images of keyhole under different welding conditions, the correlations of the main welding process parameters (welding current, welding speed, plasma gas flow rate) with the keyhole length, width and area are visualized through vision measurement. It lays a solid foundation for implementing keyhole stability control and process optimization in keyhole PAW. (paper)

  19. Powder processing and spheroidizing with thermal inductively coupled plasma

    International Nuclear Information System (INIS)

    Nutsch, G.; Linke, P.; Zakharian, S.; Dzur, B.; Weiss, K.-H.

    2001-01-01

    Processing of advanced powder materials for the spraying industry is one of the most promising applications of the thermal RF inductively coupled plasma. By selecting the feedstock carefully and adjusting the RF plasma parameters, unique materials with high quality can be achieved. Powders injected in the hot plasma core emerge with modified shapes, morphology, crystal structure and chemical composition. Ceramic oxide powders such as Al 2 O 3 , ZrO 2 , SiO 2 are spheroidized with a high spheroidization rate. By using the RF induction plasma spheroidizing process tungsten melt carbide powders are obtained with a high spheroidization rate at high feeding rates by densification of agglomerated powders consisting of di-tungsten carbide and monocarbide with a definite composition. This kind of ball-like powders is particularly suited for wear resistant applications. (author)

  20. Incidence and clinical vital parameters in primary ketosis of Murrah buffaloes

    Science.gov (United States)

    Kumar, Ankit; Sindhu, Neelesh; Kumar, Parmod; Kumar, Tarun; Charaya, Gaurav; Surbhi; Jain, V. K.; Sridhar

    2015-01-01

    Aim: The present study was undertaken to ascertain the incidence and clinical vital parameters in cases of primary ketosis in Murrah buffaloes brought to teaching veterinary clinical complex, Lala Lajpat Rai University of Veterinary and Animal Sciences, Hisar and from adjoining villages of the district Hisar, Haryana, India. Materials and Methods: The investigation was conducted on 24 clinical cases (out of total 145 screened) of primary ketosis. The diagnosis was confirmed on the basis of clinical signs and significantly positive two tests for ketone bodies in urine (Rothera’s and Keto-Diastix strip test). Data collected were statistically analyzed using independent Student’s t-test. Results: Overall incidence of disease in these areas was found to be 16.55% and all the animals were recently parturited (mean: 1.42±0.14 month), on an average in their third lactation (mean: 2.38±0.30) and exhibited clinical signs such as selective anorexia (refusal to feed on concentrate diet), drastic reduction in milk yield (mean: 64.4±5.35%), ketotic odor from urine, breath, and milk and rapid loss of body condition. All the clinical vital parameters in ketotic buffaloes (body temperature, heart rate, respiration rate, and rumen movements) were within normal range. Conclusion: Primary ketosis in Murrah buffaloes was the most common seen in the third lactation, within the first 2 months after parturition with characteristics clinical signs and no variability in vital parameters. The disease has severe effect on the production status of affected animal. PMID:27047203

  1. Incidence and clinical vital parameters in primary ketosis of Murrah buffaloes

    Directory of Open Access Journals (Sweden)

    Ankit Kumar

    2015-09-01

    Full Text Available Aim: The present study was undertaken to ascertain the incidence and clinical vital parameters in cases of primary ketosis in Murrah buffaloes brought to teaching veterinary clinical complex, Lala Lajpat Rai University of Veterinary and Animal Sciences, Hisar and from adjoining villages of the district Hisar, Haryana, India. Materials and Methods: The investigation was conducted on 24 clinical cases (out of total 145 screened of primary ketosis. The diagnosis was confirmed on the basis of clinical signs and significantly positive two tests for ketone bodies in urine (Rothera’s and Keto-Diastix strip test. Data collected were statistically analyzed using independent Student’s t-test. Results: Overall incidence of disease in these areas was found to be 16.55% and all the animals were recently parturited (mean: 1.42±0.14 month, on an average in their third lactation (mean: 2.38±0.30 and exhibited clinical signs such as selective anorexia (refusal to feed on concentrate diet, drastic reduction in milk yield (mean: 64.4±5.35%, ketotic odor from urine, breath, and milk and rapid loss of body condition. All the clinical vital parameters in ketotic buffaloes (body temperature, heart rate, respiration rate, and rumen movements were within normal range. Conclusion: Primary ketosis in Murrah buffaloes was the most common seen in the third lactation, within the first 2 months after parturition with characteristics clinical signs and no variability in vital parameters. The disease has severe effect on the production status of affected animal.

  2. Temporal evolution of the spectral lines emission and temperatures in laser induced plasmas through characteristic parameters

    Energy Technology Data Exchange (ETDEWEB)

    Bredice, F., E-mail: faustob@ciop.unlp.edu.ar [Centro de Investigaciones Ópticas, P.O. Box 3 C. P.1897 Gonnet, La Plata (Argentina); Pacheco Martinez, P. [Grupo de Espectroscopía Óptica de Emisión y Láser, Universidad del Atlántico, Barranquilla (Colombia); Sánchez-Aké, C.; Villagrán-Muniz, M. [Laboratorio de Fotofísica, Centro de Ciencias Aplicadas y Desarrollo Tecnológico, Universidad Nacional Autónoma de México, Apartado Postal 70-186, México D.F. 04510 (Mexico)

    2015-05-01

    In this work, we propose an extended Boltzmann plot method to determine the usefulness of spectral lines for plasma parameter calculations. Based on the assumption that transient plasmas are under ideal conditions during an specific interval of time Δt, (i.e. thin, homogeneous and in local thermodynamic equilibrium (LTE)), the associated Boltzmann plots describe a surface in the space defined by the coordinates X = Energy, Y = Time and Z = ln (λ{sub jl}I{sub j}/g{sub j}A{sub jl}), where I{sub j} is the integrated intensity of the spectral line, g{sub j} is the statistical weight of the level j, λ{sub jl} is the wavelength of the considered line and A{sub jl} is its transition rate. In order to express the Boltzmann plot surface in terms of a reduced set of constants B{sub i}, and δ{sub i}, we developed as a power series of time, the logarithm of I{sub n}(t)/I{sub n}(t{sub 0}), where I{sub n}(t) is the integrated intensity of any spectral line at time t, and I{sub n}(t{sub 0}) at initial time. Moreover, the temporal evolution of the intensity of any spectral line and consequently the temperature of the plasma can be also expressed with these constants. The comparison of the temporal evolution of the line intensity calculated using these constants with their experimental values, can be used as a criterion for selecting useful lines in plasma analysis. Furthermore, this method can also be applied to determine self-absorption or enhancement of the spectral lines, to evaluate a possible departure of LTE, and to check or estimate the upper level energy value of any spectral line. An advantage of this method is that the value of these constants does not depend on the spectral response of the detection system, the uncertainty of the transition rates belonging to the analyzed spectral lines or any other time-independent parameters. In order to prove our method, we determined the constants B{sub i} and δ{sub i} and therefore the Boltzmann plot surface from the temporal

  3. A study of evolution/suppression parameters of equatorial postsunset plasma instability

    Directory of Open Access Journals (Sweden)

    O. S. Oyekola

    2009-01-01

    Full Text Available Evening equatorial pre-reversal vertical ion E×B drift (VZP and the peak of the ionospheric F2 maximum altitude (hmF2P of the postsunset equatorial F-layer, which are the essential parameters requisite for the generation or inhibition of postsunset bottomside equatorial irregularities were deduced from ionosonde observations made in the Africa region (Ouagadougou: ~3° N dip latitude between January 1987 and December 1990 for solar activity minimum, medium, and maxima (F10.7=85, 141, 214, and 190, respectively for quiet geomagnetic conditions. We investigate variations of evening equatorial pre-reversal drift and the corresponding altitude at four levels of solar activity. Our observations show strong variations with solar variability. Correlation analysis between these parameters indicates that the correlation coefficient value between hmF2P versus VZP decreases considerably with increasing solar flux value. There seems to be no significant link between these parameters under high solar activity, especially for solar intensity F10.7>200 units. We conclude that meridional neutral wind in the F-region contributes substantially to the variations of the pre-reversal vertical plasma drifts enhancement and the peak hmF2, particularly the electrodynamics during twilight high solar flux conditions.

  4. Static analysis of the thermochemical hydrogen production IS process for assessment of the operation parameters and the chemical properties

    International Nuclear Information System (INIS)

    Kasahara, Seiji; Onuki, Kaoru; Nomura, Mikihiro; Nakao, Shin-ichi

    2006-01-01

    A sensitivity analysis of the operation parameters and the chemical properties in the thermochemical hydrogen production IS process (iodine-sulfur process) was carried out for a static flow sheet. These parameters were evaluated by hydrogen production thermal efficiency, the mass flow rate or heat exchange based on the heat/mass balance. The most important parameters were the concentration of HI after electro-electrodialysis (EED) and the apparent transport number of protons of the cation exchange membrane in the EED cell. HI concentration operation should be operated carefully because the parameters for optimum thermal efficiency and for the optimum flow rate and heat exchange were different. For the chemical properties, composition at the inlet of the HI decomposition procedure and HI x pseudo-azeotropic composition had great effects. The HI concentration after the EED should be optimized for each composition. The order of priority for the assessment of the operation parameters and chemical properties was determined by the evaluation. (author)

  5. Nanocapillary Atmospheric Pressure Plasma Jet: A Tool for Ultrafine Maskless Surface Modification at Atmospheric Pressure.

    Science.gov (United States)

    Motrescu, Iuliana; Nagatsu, Masaaki

    2016-05-18

    With respect to microsized surface functionalization techniques we proposed the use of a maskless, versatile, simple tool, represented by a nano- or microcapillary atmospheric pressure plasma jet for producing microsized controlled etching, chemical vapor deposition, and chemical modification patterns on polymeric surfaces. In this work we show the possibility of size-controlled surface amination, and we discuss it as a function of different processing parameters. Moreover, we prove the successful connection of labeled sugar chains on the functionalized microscale patterns, indicating the possibility to use ultrafine capillary atmospheric pressure plasma jets as versatile tools for biosensing, tissue engineering, and related biomedical applications.

  6. Study of plasma parameters influencing fractionation in laser ablation-inductively coupled plasma-mass spectrometry

    Science.gov (United States)

    Gäckle, M.; Merten, D.

    2010-12-01

    Methods permitting to test the influence of the matrix as well as of its local and temporal distribution on the plasma conditions in laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS) are developed. For this purpose, the MS interface is used as plasma probe allowing to investigate the average plasma condition within the ICP zone observed in terms of temporal and spatial distribution of the matrix. Inserted matrix particles, particularly when being atomized and ionized, can cause considerable changes in both electron density and plasma temperature thus influencing the ionization equilibrium of the individual analytes. In this context, the plasma probe covers a region of the plasma for which no local thermodynamic equilibrium can be assumed. The differences in temperature, identified within the region of the plasma observed, amounted up to 3000 K. While in the central region conditions were detected that would not allow efficient atomization and ionization of the matrix, these conditions improve considerably towards the margin of the area observed. Depending on the nature as well as on the temporally and locally variable density of the matrix, this can lead to varying intensity ratios of the analytes and explain fractionation effects. By means of a derived equation it is shown that the deviation of the intensity ratio from the concentration ratio turns out to be more serious the higher the difference of the ionization potential of the analytes observed, the lower the plasma temperature and the higher the matrix concentration within the area observed.

  7. Error estimation and global fitting in transverse-relaxation dispersion experiments to determine chemical-exchange parameters

    International Nuclear Information System (INIS)

    Ishima, Rieko; Torchia, Dennis A.

    2005-01-01

    Off-resonance effects can introduce significant systematic errors in R 2 measurements in constant-time Carr-Purcell-Meiboom-Gill (CPMG) transverse relaxation dispersion experiments. For an off-resonance chemical shift of 500 Hz, 15 N relaxation dispersion profiles obtained from experiment and computer simulation indicated a systematic error of ca. 3%. This error is three- to five-fold larger than the random error in R 2 caused by noise. Good estimates of total R 2 uncertainty are critical in order to obtain accurate estimates in optimized chemical exchange parameters and their uncertainties derived from χ 2 minimization of a target function. Here, we present a simple empirical approach that provides a good estimate of the total error (systematic + random) in 15 N R 2 values measured for the HIV protease. The advantage of this empirical error estimate is that it is applicable even when some of the factors that contribute to the off-resonance error are not known. These errors are incorporated into a χ 2 minimization protocol, in which the Carver-Richards equation is used fit the observed R 2 dispersion profiles, that yields optimized chemical exchange parameters and their confidence limits. Optimized parameters are also derived, using the same protein sample and data-fitting protocol, from 1 H R 2 measurements in which systematic errors are negligible. Although 1 H and 15 N relaxation profiles of individual residues were well fit, the optimized exchange parameters had large uncertainties (confidence limits). In contrast, when a single pair of exchange parameters (the exchange lifetime, τ ex , and the fractional population, p a ), were constrained to globally fit all R 2 profiles for residues in the dimer interface of the protein, confidence limits were less than 8% for all optimized exchange parameters. In addition, F-tests showed that quality of the fits obtained using τ ex , p a as global parameters were not improved when these parameters were free to fit the R

  8. Surface chemical structure of poly(ethylene naphthalate) films during degradation in low-pressure high-frequency plasma treatments

    Science.gov (United States)

    Kamata, Noritsugu; Yuji, Toshifumi; Thungsuk, Nuttee; Arunrungrusmi, Somchai; Chansri, Pakpoom; Kinoshita, Hiroyuki; Mungkung, Narong

    2018-06-01

    The surface chemical structure of poly(ethylene naphthalate) (PEN) films treated with a low-pressure, high-frequency plasma was investigated by storing in a box at room temperature to protect the PEN film surface from dust. The functional groups on the PEN film surface changed over time. The functional groups of –C=O, –COH, and –COOH were abundant in the Ar + O2 mixture gas plasma-treated PEN samples as compared with those in untreated PEN samples. The changes occurred rapidly after 2 d following the plasma treatment, reaching steady states 8 d after the treatment. Hydrophobicity had an inverse relationship with the concentration of these functional groups on the surface. Thus, the effect of the low-pressure high-frequency plasma treatment on PEN varies as a function of storage time. This means that radical oxygen and oxygen molecules are clearly generated in the plasma, and this is one index to confirm that radical reaction has definitely occurred between the gas and the PEN film surface with a low-pressure high-frequency plasma.

  9. Plasma-activation of tap water using DBD for agronomy applications: Identification and quantification of long lifetime chemical species and production/consumption mechanisms.

    Science.gov (United States)

    Judée, F; Simon, S; Bailly, C; Dufour, T

    2018-04-15

    Cold atmospheric plasmas are weakly ionized gases that can be generated in ambient air. They produce energetic species (e.g. electrons, metastables) as well as reactive oxygen species, reactive nitrogen species, UV radiations and local electric field. Their interaction with a liquid such as tap water can hence change its chemical composition. The resulting "plasma-activated liquid" can meet many applications, including medicine and agriculture. Consequently, a complete experimental set of analytical techniques dedicated to the characterization of long lifetime chemical species has been implemented to characterize tap water treated using cold atmospheric plasma process and intended to agronomy applications. For that purpose, colorimetry and acid titrations are performed, considering acid-base equilibria, pH and temperature variations induced during plasma activation. 16 species are quantified and monitored: hydroxide and hydronium ions, ammonia and ammonium ions, orthophosphates, carbonate ions, nitrite and nitrate ions and hydrogen peroxide. The related consumption/production mechanisms are discussed. In parallel, a chemical model of electrical conductivity based on Kohlrausch's law has been developed to simulate the electrical conductivity of the plasma-activated tap water (PATW). Comparing its predictions with experimental measurements leads to a narrow fitting, hence supporting the self-sufficiency of the experimental set, I.e. the fact that all long lifetime radicals of interest present in PATW are characterized. Finally, to evaluate the potential of cold atmospheric plasmas for agriculture applications, tap water has been daily plasma-treated to irrigate lentils seeds. Then, seedlings lengths have been measured and compared with untreated tap water, showing an increase as high as 34.0% and 128.4% after 3 days and 6 days of activation respectively. The interaction mechanisms between plasma and tap water are discussed as well as their positive synergy on

  10. Influence of an External DC Electric Current on Plasma Cleaning Rate: an Application on the Enlarged Plasma-Surface Theory

    International Nuclear Information System (INIS)

    Xaplanteris, Constantine L.; Filippaki, Eleni D.

    2013-01-01

    During the last decades many researchers have been occupied with other plasma applications apart from the big challenge which the thermonuclear fusion poses. Many experiments have been carried out on the plasma behavior in contact with a solid surface; when the surface material consists of chemical compounds (e.g. oxides of metals), then the plasma chemistry takes place. The present paper contains the final experimental and theoretical work of Plasma Laboratory at “Demokritos , which consists of an elaboration of plasma sheath parameters adapted to experimental conditions, a suitable choice of plasma gases (either H 2 or N 2 ), and an electric potential current enforcement on objects. Additionally, a brief theory is given to explain the results, with a short reference to both boundary phenomena in thermonuclear reactors and low pressure plasma of glow discharges, so as to reveal the similarities and differences of these two cases. An extensive examination of the treated objects by X-ray diffraction method (XRD) gives results in agreement with the theoretical predictions. Using this improvement on plasma restoration system, (a combination of electric current on metallic object into suitable plasma), it is shown that better results can be achieved on the cleaning and conservation of archaeological objects. (plasma technology)

  11. Chemically induced transition phenomena in polyurethanes as seen from generalized mode Grueneisen parameters

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, U; Philipp, M; Bactavatchalou, R; Sanctuary, R; Baller, J; Zielinski, B; Krueger, J K [Laboratoire de Physique des Materiaux, Universite du Luxembourg, 162A, Avenue de la Faiencerie, L-1115 (Luxembourg); Possart, W; Alnot, P [Laboratoire Europeen de Recherche, Universitaire Saarland-Lorraine (Luxembourg)], E-mail: ulrich.mueller@uni.lu

    2008-05-21

    Many phenomenological properties of reactive polymers like polyurethanes increase or decrease continuously in the course of the curing process before saturating at the end of the chemical reaction. This holds true for instance for the mass density, the refractive index, the chemical turnover and the hypersonic properties. The reason for this monotone behaviour is that the chemical reaction behaves like a continuous succession of irreversible phase transitions. These transitions are superposed by the sol-gel transition and possibly by the chemically induced glass transition, with the drawback that the latter two highlighted transitions are often hidden by the underlying curing process. In this work we propose generalized mode Grueneisen parameters as an alternative probe for elucidating the polymerization process itself and the closely related transition phenomena. As a model system we use polyurethane composed of a diisocyanate and varying ratios of difunctional and trifunctional alcohols.

  12. Diamond synthesis at atmospheric pressure by microwave capillary plasma chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Hemawan, Kadek W.; Gou, Huiyang; Hemley, Russell J. [Geophysical Laboratory, Carnegie Institution of Washington, 5251 Broad Branch Rd., NW, Washington, DC 20015 (United States)

    2015-11-02

    Polycrystalline diamond has been synthesized on silicon substrates at atmospheric pressure, using a microwave capillary plasma chemical vapor deposition technique. The CH{sub 4}/Ar plasma was generated inside of quartz capillary tubes using 2.45 GHz microwave excitation without adding H{sub 2} into the deposition gas chemistry. Electronically excited species of CN, C{sub 2}, Ar, N{sub 2}, CH, H{sub β}, and H{sub α} were observed in the emission spectra. Raman measurements of deposited material indicate the formation of well-crystallized diamond, as evidenced by the sharp T{sub 2g} phonon at 1333 cm{sup −1} peak relative to the Raman features of graphitic carbon. Field emission scanning electron microscopy images reveal that, depending on the growth conditions, the carbon microstructures of grown films exhibit “coral” and “cauliflower-like” morphologies or well-facetted diamond crystals with grain sizes ranging from 100 nm to 10 μm.

  13. Capillary plasma jet: A low volume plasma source for life science applications

    Energy Technology Data Exchange (ETDEWEB)

    Topala, I., E-mail: ionut.topala@uaic.ro, E-mail: tmnagat@ipc.shizuoka.ac.jp [Alexandru Ioan Cuza University of Iasi, Faculty of Physics, Iasi Plasma Advanced Research Center (IPARC), Bd. Carol I No. 11, Iasi 700506 (Romania); Nagatsu, M., E-mail: ionut.topala@uaic.ro, E-mail: tmnagat@ipc.shizuoka.ac.jp [Graduate School of Science and Technology, Shizuoka University, 3-5-1 Johoku, Naka-ku, Hamamatsu 432-8561 (Japan)

    2015-02-02

    In this letter, we present results from multispectroscopic analysis of protein films, after exposure to a peculiar plasma source, i.e., the capillary plasma jet. This plasma source is able to generate very small pulsed plasma volumes, in kilohertz range, with characteristic dimensions smaller than 1 mm. This leads to specific microscale generation and transport of all plasma species. Plasma diagnosis was realized using general electrical and optical methods. Depending on power level and exposure duration, this miniature plasma jet can induce controllable modifications to soft matter targets. Detailed discussions on protein film oxidation and chemical etching are supported by results from absorption, X-ray photoelectron spectroscopy, and microscopy techniques. Further exploitation of principles presented here may consolidate research interests involving plasmas in biotechnologies and plasma medicine, especially in patterning technologies, modified biomolecule arrays, and local chemical functionalization.

  14. Capillary plasma jet: A low volume plasma source for life science applications

    Science.gov (United States)

    Topala, I.; Nagatsu, M.

    2015-02-01

    In this letter, we present results from multispectroscopic analysis of protein films, after exposure to a peculiar plasma source, i.e., the capillary plasma jet. This plasma source is able to generate very small pulsed plasma volumes, in kilohertz range, with characteristic dimensions smaller than 1 mm. This leads to specific microscale generation and transport of all plasma species. Plasma diagnosis was realized using general electrical and optical methods. Depending on power level and exposure duration, this miniature plasma jet can induce controllable modifications to soft matter targets. Detailed discussions on protein film oxidation and chemical etching are supported by results from absorption, X-ray photoelectron spectroscopy, and microscopy techniques. Further exploitation of principles presented here may consolidate research interests involving plasmas in biotechnologies and plasma medicine, especially in patterning technologies, modified biomolecule arrays, and local chemical functionalization.

  15. Chemical Abundances and Physical Parameters of H II Regions in the Magellanic Clouds

    Science.gov (United States)

    Reyes, R. E. C.

    The chemical abundances and physical parameters of H II regions are important pa rameters to determine in order to understand how stars and galaxies evolve. The Magellanic Clouds offer us a unique oportunity to persue such studies in low metallicity galaxies. In this contribution we present the results of the photoionization modeling of 5 H II regions in each of the Large Magellanic Cloud (LMC) and Small Magellanic Cloud (SMC) sys tems. Optical data were collected from the literature, complemented by our own observa tions (Carlos Reyes et al. 1998), including UV spectra from the new IUE data ban k and infrared fluxes from the IRAS satellite. The chemical abundances of He, C, N, O, Ne, S, Ar and physical parameters like the densities, the ionized masses, the luminosities, the ionization temperatures , the filling factor and optical depth are determined. A comparison of the abundances of these HII regions with those of typical planetary nebulae and supergiants stars is also presented.

  16. Reference values of clinical chemistry and hematology parameters in rhesus monkeys (Macaca mulatta).

    Science.gov (United States)

    Chen, Younan; Qin, Shengfang; Ding, Yang; Wei, Lingling; Zhang, Jie; Li, Hongxia; Bu, Hong; Lu, Yanrong; Cheng, Jingqiu

    2009-01-01

    Rhesus monkey models are valuable to the studies of human biology. Reference values for clinical chemistry and hematology parameters of rhesus monkeys are required for proper data interpretation. Whole blood was collected from 36 healthy Chinese rhesus monkeys (Macaca mulatta) of either sex, 3 to 5 yr old. Routine chemistry and hematology parameters, and some special coagulation parameters including thromboelastograph and activities of coagulation factors were tested. We presented here the baseline values of clinical chemistry and hematology parameters in normal Chinese rhesus monkeys. These data may provide valuable information for veterinarians and investigators using rhesus monkeys in experimental studies.

  17. Characterization of thin TiO2 films prepared by plasma enhanced chemical vapour deposition for optical and photocatalytic applications

    International Nuclear Information System (INIS)

    Sobczyk-Guzenda, A.; Gazicki-Lipman, M.; Szymanowski, H.; Kowalski, J.; Wojciechowski, P.; Halamus, T.; Tracz, A.

    2009-01-01

    Thin titanium oxide films were deposited using a radio frequency (RF) plasma enhanced chemical vapour deposition method. Their optical properties and thickness were determined by means of ultraviolet-visible absorption spectrophotometry. Films of the optical parameters very close to those of titanium dioxide have been obtained at the high RF power input. Their optical quality is high enough to allow for their use in a construction of stack interference optical filters. At the same time, these materials exhibit strong photocatalytic effects. The results of structural analysis, carried out by Raman Shift Spectroscopy, show that the coatings posses amorphous structure. However, Raman spectra of the same films subjected to thermal annealing at 450 o C disclose an appearance of a crystalline form, namely that of anatase. Surface morphology of the films has also been characterized by Atomic Force Microscopy revealing granular, broccoli-like topography of the films.

  18. Characteristics of SiOx-containing hard film prepared by low temperature plasma enhanced chemical vapor deposition using hexamethyldisilazane or vinyltrimethylsilane and post oxygen plasma treatment

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Yi-Syuan; Liu, Wan-Yu; Wu, Hsin-Ming [Department of Materials Engineering, Tatung University, Taipei, 104, Taiwan (China); Chen, Ko-Shao, E-mail: kschen@ttu.edu.tw [Department of Materials Engineering, Tatung University, Taipei, 104, Taiwan (China); Cech, Vladimir [Institute of Materials Chemistry, Brno University of Technology (Czech Republic)

    2017-03-01

    This study, monomers of hexamethyldisilazane (HMDSZ) and vinyltrimethylsilane (VTMS) were respectively used to deposit on the surface of polyethylene terephthalate (PET) substrate by plasma enhanced chemical vapor deposition. Oxygen plasma treatment follows the HMDSZ and VTMS deposition to produce a hydrophilic surface film on the deposited surface. Time for HMDSZ and VTMS plasma deposition was changed to investigate its influences on water contact angle, deposited film thickness, refractive index, and friction coefficient properties. The surface morphologies of the processed samples were observed by scanning electron microscope and their chemical compositions were measured by X-ray photoelectron spectroscopy. At 550 nm wavelength, the optical transmittance of PET after the HMDSZ treatment decreases from 89% to 83%, but increases from 89% to 95% for the VTMS treatment. With increase in HMDSZ and VTMS deposition times, the film thickness increases and the refractive index decreases. Result revealed by XPS, SiO{sub 2} film is formed on the sample surface after the O{sub 2} plasma treatment. The film adhesion capability by the HMDSZ+O{sub 2} and VTMS+O{sub 2} treatment was stronger than that by the HMDSZ and VTMS treatment only. The SiOx films produced by HMDSZ+O{sub 2} and VTMS+O{sub 2} treatment can increase the film hardness and improve light transmittance. - Highlights: • With increase in HMDSZ and VTMS deposition times, the film thickness increases and the refractive index decreases. • The optical transmittance of PET after the VTMS treatment increases from 89% to 95%. • The SiO{sub 2} films deposited by HMDSZ+O{sub 2} and VTMS+O{sub 2} plasma can increase the film hardness and improve light transmittance. • It is expected that they can be applied to the optical transmittance protective film on plastic substrate in the future.

  19. Influence of plasma parameters in pulsed plasma gun on modification processes in exposed structural materials

    International Nuclear Information System (INIS)

    Byrka, O.V.; Bandura, A.N.; Chebotarev, V.V.; Garkusha, I.E.; Garkusha, V.V.; Makhai, V.A.; Tereshin, V.I.

    2011-01-01

    This paper is focused on investigation of helium, nitrogen and krypton plasma streams generated by pulsed plasma gun (PPA). The main objection of this study is adjustment of plasma treatment regimes for different materials that allows achieving optimal thickness of modified layer with simultaneously minimal value of surface roughness. Features of materials alloying from gas and metallic plasma as a result of the plasma ions mixing with the steel substrate in liquid phase are discussed also.

  20. Contact glow discharge electrolysis: its origin, plasma diagnostics and non-faradaic chemical effects

    International Nuclear Information System (INIS)

    Sen Gupta, Susanta K

    2015-01-01

    Contact glow discharge electrolysis (CGDE) also termed plasma electrolysis is a novel electrolysis where a stable sheath of light emitting plasma develops around an electrode immersed well inside a relatively high-conductivity liquid electrolyte during normal electrolysis (NE) at several hundred volts. The phenomenon may develop in dc-, pulsed dc-, ac- as well as RF-driven electrolyses. The chemical effects of CGDE are remarkably non-faradaic in respect to the nature of the products as well as their yields. The article traces comprehensively the progress made in studies of CGDE in aqueous and non-aqueous solutions since 1844 and reviews the developments in the understanding of its origin, light emission, plasma state and non-faradaic effects leading to the elucidation of detailed mechanism of the origin of CGDE on the basis of the onset of hydrodynamic instabilities in local vaporization of the solvent near the working electrode during NE, and that of highly non-faradaic effects of CGDE based on a model of two reaction zones located within the electrode plasma and at the plasma–liquid interface producing solvent derived radicals at high local concentrations. Keeping in view the recent surge of interest in varied applications of CGDE, the article is appended with highlights of these applications across synthetic chemistry, waste water treatment, electrosurgical devices, nanoparticle fabrications, surface engineering and micro-machining. (topical review)

  1. Analytical investigation on domain of decentered parameter for self-focusing of Hermite-cosh-Gaussian laser beam in collisional plasma

    Science.gov (United States)

    Valkunde, Amol T.; Patil, Sandip D.; Vhanmore, Bandopant D.; Urunkar, Trupti U.; Gavade, Kusum M.; Takale, Mansing V.; Fulari, Vijay J.

    2018-03-01

    In the present paper, an analytically investigated domain of decentered parameter and its effect on the self-focusing of Hermit-cosh-Gaussian (HChG) laser beams in a collisional plasma have been studied theoretically. The nonlinearity in the dielectric constant of plasma arising due to the nonuniform heating of carriers along the wavefront of the laser beam has been employed in the present investigation. The nonlinear differential equation of beam width parameter for various laser modes of HChG beam is obtained by following the standard Akhamanov's parabolic equation approach under Wentzel-Kramers-Brillouin and paraxial approximations. The analytical treatment has enabled us to define three distinct regions: self-focusing, self-trapping and defocusing, which are presented graphically.

  2. Polycrystalline AlN films with preferential orientation by plasma enhanced chemical vapor deposition

    International Nuclear Information System (INIS)

    Sanchez, G.; Wu, A.; Tristant, P.; Tixier, C.; Soulestin, B.; Desmaison, J.; Bologna Alles, A.

    2008-01-01

    AlN thin films for acoustic wave devices were prepared by Microwave Plasma Enhanced Chemical Vapor Deposition under different process conditions, employing Si (100) and Pt (111)/SiO 2 /Si (100) substrates. The films were characterized by X-ray diffraction, Fourier transform infrared transmission spectroscopy, atomic force microscopy, scanning electron microscopy, and transmission electron microscopy. The values of the distance between the plasma and the tri-methyl-aluminum precursor injector, the radiofrequency bias potential, and the substrate temperature were central in the development of polycrystalline films. The choice of the chamber total pressure during deposition allowed for the development of two different crystallographic orientations, i.e., or . The film microstructures exhibited in general a column-like growth with rounded tops, an average grain size of about 40 nm, and a surface roughness lower than 20 nm under the best conditions

  3. Production of a hot ion plasma at the lower hybrid resonance and measurement of its parameters

    International Nuclear Information System (INIS)

    Glagolev, V.M.; Dyubajlov, A.G.; Krivov, N.A.; Martynenko, V.V.; Skosyrev, Yu.V.

    1975-01-01

    Electromagnetic fields delayed along a magnetic field have been created within a plasma with the aid of a coil encircling the plasma column. When these waves were propagated transversely in relation to the magnetic field in a plasma with density rising along its radius, they were delayed in the direction of propagation. The amplitude and phase distributions of the electromagentic fields along the radius of the plasma column were measured at different moments in time. The existence of an absorption band of these waves within the plasma was detected. The absorption band was shifted towards the outer boundary from the plasma when plasma density was increased. By four independent methods it was established that the gas-kinetic pressure of the plasma, measured according to its diamagnetism, is determined by the ion component. It was found that the energy of electrons at right angles to the magnetic field is considerably less than that of the ions. The cause of limited heating was an increase in density and energy losses in the charge-exchange process. In order to improve vacuum conditions, the coil around the plasma was placed in a metallic chamber, and the UHF plasma source used in the original experiments was replaced by a hydride-film source. This made it possible to increase the internal energy of the plasma to 3x10 15 eV cm -3 at a density of (1-3)x10 12 cm -3 . The mean energy of atoms leaving the plasma at right angles to the magnetic field as a result of charge exchange reached 1 keV. The region of change in plasma parameters (density and magnetic field) for which heating was observed corresponded to the linear transformation theory. Non-linear effects could occur only in the first stage of heating, when the electric fields were strong, but plasma temperature was low. Heating efficiency was measured by a reflectometer installed in the coaxial line connecting the generator and the HF input coil to the plasma. The measurements showed that about 20% of the power

  4. First in situ plasma and neutral gas measurements at comet Halley: initial VEGA results

    International Nuclear Information System (INIS)

    Gringauz, K.I.; Remizov, A.P.; Gombosi, T.I.

    1986-04-01

    The first in situ observations and a description of the large scale behaviour of comet Halley's plasma environment are presented. The scientific objectives of the PLASMAG-1 experiment were as follows: to study the change of plasma parameters and distributions as a function of cometocentric distance; to investigate the existence and structure of the cometary bow shock; to determine the change in chemical composition of the heavily mass loaded plasma as the spacecraft approached the comet; and to measure the neutral gas distribution along the spacecraft trajectory. (author)

  5. Clinical Parameters following Multiple Oral Dose Administration of a Standardized Andrographis paniculata Capsule in Healthy Thai Subjects.

    Science.gov (United States)

    Suriyo, Tawit; Pholphana, Nanthanit; Ungtrakul, Teerapat; Rangkadilok, Nuchanart; Panomvana, Duangchit; Thiantanawat, Apinya; Pongpun, Wanwisa; Satayavivad, Jutamaad

    2017-06-01

    Andrographis paniculata has been widely used in Scandinavian and Asian counties for the treatment of the common cold, fever, and noninfectious diarrhea. The present study was carried out to investigate the physiological effects of short-term multiple dose administration of a standardized A. paniculata capsule used for treatment of the common cold and uncomplicated upper respiratory tract infections, including blood pressure, electrocardiogram, blood chemistry, hematological profiles, urinalysis, and blood coagulation in healthy Thai subjects. Twenty healthy subjects (10 males and 10 females) received 12 capsules per day orally of 4.2 g of a standardized A. paniculata crude powder (4 capsules of 1.4 g of A. paniculata , 3 times per day, 8 h intervals) for 3 consecutive days. The results showed that all of the measured clinical parameters were found to be within normal ranges for a healthy person. However, modulation of some parameters was observed after the third day of treatment, for example, inductions of white blood cells and absolute neutrophil count in the blood, a reduction of plasma alkaline phosphatase, and an induction of urine pH. A rapid and transient reduction in blood pressure was observed at 30 min after capsule administration, resulting in a significant reduction of mean systolic blood pressure. There were no serious adverse events observed in the subjects during the treatment period. In conclusion, this study suggests that multiple oral dosing of A. paniculata at the normal therapeutic dose for the common cold and uncomplicated upper respiratory tract infections modulates various clinical parameters within normal ranges for a healthy person. Georg Thieme Verlag KG Stuttgart · New York.

  6. Application of plasma technology for the modification of polymer and textile materials

    Directory of Open Access Journals (Sweden)

    Radetić Maja M.

    2004-01-01

    Full Text Available Plasma treatment is based on the physico-chemical changes of the material surface and as an ecologically and economically acceptable process it can be an attractive alternative to conventional modifications. The possibilities of plasma technology application to the modification of polymer and textile materials are discussed. Different specific properties of the material can be achieved by plasma cleaning, etching, functionalization or polymerization. The final effects are strongly influenced by the treatment parameters (treatment time, pressure, power, gas flow, the applied gas and nature of the material. The plasma treatment of polymers is predominantly focused on cleaning and activation of the surfaces to increase adhesion, binding, wettability, dye ability and printability. Current studies deal more with plasma polymerization where an ultra thin film of plasma polymer is deposited on the material surface and, depending on the applied monomer, different specific properties can be obtained (i.e. chemical and thermal resistance, abrasion resistance, antireflexion, water repellence, etc.. Plasma application to textiles is mostly oriented toward wool and synthetic fibres, though some studies also consider cotton, hemp, flax and silk. The main goal of plasma treatment is to impart a more hydrophilic fibre surface and accordingly increase wettability, dye ability, printability and particularly, shrink resistance in the case of wool. Recent studies have favored technical textiles, where plasma polymerization can offer a wide range of opportunities.

  7. Non-equilibrium plasma reactor for natrual gas processing

    International Nuclear Information System (INIS)

    Shair, F.H.; Ravimohan, A.L.

    1974-01-01

    A non-equilibrium plasma reactor for natural gas processing into ethane and ethylene comprising means of producing a non-equilibrium chemical plasma wherein selective conversion of the methane in natural gas to desired products of ethane and ethylene at a pre-determined ethane/ethylene ratio in the chemical process may be intimately controlled and optimized at a high electrical power efficiency rate by mixing with a recycling gas inert to the chemical process such as argon, helium, or hydrogen, reducing the residence time of the methane in the chemical plasma, selecting the gas pressure in the chemical plasma from a wide range of pressures, and utilizing pulsed electrical discharge producing the chemical plasma. (author)

  8. Structural and optical characterization of self-assembled Ge nanocrystal layers grown by plasma-enhanced chemical vapor deposition

    NARCIS (Netherlands)

    Saeed, S.; Buters, F.; Dohnalova, K.; Wosinski, L.; Gregorkiewicz, T.

    2014-01-01

    We present a structural and optical study of solid-state dispersions of Ge nanocrystals prepared by plasma-enhanced chemical vapor deposition. Structural analysis shows the presence of nanocrystalline germanium inclusions embedded in an amorphous matrix of Si-rich SiO2. Optical characterization

  9. Decontamination of chemical and biological warfare (CBW) agents using an atmospheric pressure plasma jet (APPJ)

    International Nuclear Information System (INIS)

    Herrmann, H.W.; Henins, I.; Park, J.; Selwyn, G.S.

    1999-01-01

    The atmospheric pressure plasma jet (APPJ) [A. Schuetze et al., IEEE Trans. Plasma Sci. 26, 1685 (1998)] is a nonthermal, high pressure, uniform glow plasma discharge that produces a high velocity effluent stream of highly reactive chemical species. The discharge operates on a feedstock gas (e.g., He/O 2 /H 2 O), which flows between an outer, grounded, cylindrical electrode and an inner, coaxial electrode powered at 13.56 MHz rf. While passing through the plasma, the feedgas becomes excited, dissociated or ionized by electron impact. Once the gas exits the discharge volume, ions and electrons are rapidly lost by recombination, but the fast-flowing effluent still contains neutral metastable species (e.g., O 2 * , He * ) and radicals (e.g., O, OH). This reactive effluent has been shown to be an effective neutralizer of surrogates for anthrax spores and mustard blister agent. Unlike conventional wet decontamination methods, the plasma effluent does not cause corrosion and it does not destroy wiring, electronics, or most plastics, making it highly suitable for decontamination of sensitive equipment and interior spaces. Furthermore, the reactive species in the effluent rapidly degrade into harmless products leaving no lingering residue or harmful by-products. copyright 1999 American Institute of Physics

  10. Chemically reacting flow of a compressible thermally radiating two-component plasma

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1990-12-01

    The paper studies the compressible flow of a hot two-component plasma in the presence of gravitation and chemical reaction in a vertical channel. For the optically thick gas approximation, closed form analytical solutions are possible. Asymptotic solutions are also obtained for the general differential approximation when the temperature of the two bounding walls are the same. In the general case the problem is reduced to the solution of standard nonlinear integral equations which can be tackled by iterative procedure. The results are discussed quantitatively. The problem may be applicable to the understanding of explosive hydrogen-burning model of solar flares. (author). 6 refs, 4 figs

  11. Nonequilibrium phenomena and determination of plasma parameters in the hot core of the cathode region in free-burning arc discharges

    International Nuclear Information System (INIS)

    Kuehn, Gerrit; Kock, Manfred

    2007-01-01

    We present spectroscopic measurements of plasma parameters (electron density n e , electron temperature T e , gas temperature T g , underpopulation factor b) in the hot-core region in front of the cathode of a low-current, free-burning arc discharge in argon under atmospheric pressure. The discharge is operated in the hot-core mode, creating a hot cathode region with plasma parameters similar to high-current arcs in spite of the fact that we use comparatively low currents (less than 20 A). We use continuum emission and (optically thin) line emission to determine n e and T e . We apply relaxation measurements based on a power-interruption technique to investigate deviations from local thermodynamic equilibrium (LTE). These measurements let us determine the gas temperature T g . All measurements are performed side-on with charge-coupled-device cameras as detectors, so that all measured plasma parameters are spatially resolved after an Abel inversion. This yields the first ever spatially resolved observation of the non-LTE phenomena of the hot core in the near-cathode region of free-burning arcs. The results only partly coincide with previously published predictions and measurements in the literature

  12. Controlling the resistivity gradient in aluminum-doped zinc oxide grown by plasma-enhanced chemical vapor deposition

    NARCIS (Netherlands)

    Ponomarev, M.; Verheijen, M.A.; Keuning, W.; Sanden, van de M.C.M.; Creatore, M.

    2012-01-01

    Aluminum-doped ZnO (ZnO:Al) grown by chemical vapor deposition (CVD) generally exhibit a major drawback, i.e., a gradient in resistivity extending over a large range of film thickness. The present contribution addresses the plasma-enhanced CVD deposition of ZnO:Al layers by focusing on the control

  13. (1)H-Nuclear magnetic resonance-based plasma metabolic profiling of dairy cows with clinical and subclinical ketosis.

    Science.gov (United States)

    Sun, L W; Zhang, H Y; Wu, L; Shu, S; Xia, C; Xu, C; Zheng, J S

    2014-03-01

    The purpose of this study was to assess the metabolic profile of plasma samples from cows with clinical and subclinical ketosis. According to clinical signs and 3-hydroxybutyrate plasma levels, 81 multiparous Holstein cows were selected from a dairy farm 7 to 21 d after calving. The cows were divided into 3 groups: cows with clinical ketosis, cows with subclinical ketosis, and healthy control cows. (1)H-Nuclear magnetic resonance-based metabolomics was used to assess the plasma metabolic profiles of the 3 groups. The data were analyzed by principal component analysis, partial least squares discriminant analysis, and orthogonal partial least-squares discriminant analysis. The differences in metabolites among the 3 groups were assessed. The orthogonal partial least-squares discriminant analysis model differentiated the 3 groups of plasma samples. The model predicted clinical ketosis with a sensitivity of 100% and a specificity of 100%. In the case of subclinical ketosis, the model had a sensitivity of 97.0% and specificity of 95.7%. Twenty-five metabolites, including acetoacetate, acetone, lactate, glucose, choline, glutamic acid, and glutamine, were different among the 3 groups. Among the 25 metabolites, 4 were upregulated, 7 were downregulated, and 14 were both upregulated and downregulated. The results indicated that plasma (1)H-nuclear magnetic resonance-based metabolomics, coupled with pattern recognition analytical methods, not only has the sensitivity and specificity to distinguish cows with clinical and subclinical ketosis from healthy controls, but also has the potential to be developed into a clinically useful diagnostic tool that could contribute to a further understanding of the disease mechanisms. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. Plasma parameters in the COMPASS divertor during Ohmic plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Dimitrova, M. [Institute of Plasma Physics, Academy of Sciences of the Czech Republic v.v.i., Prague (Czech Republic); Emil Djakov Institute of Electronics, Bulgarian Academy of Sciences, Sofia (Bulgaria); Dejarnac, R.; Stoeckel, J.; Havlicek, J.; Janky, F.; Panek, R. [Institute of Plasma Physics, Academy of Sciences of the Czech Republic v.v.i., Prague (Czech Republic); Popov, Ts.K. [Faculty of Physics, St. Kl. Ohridski University of Sofia (Bulgaria); Ivanova, P.; Vasileva, E. [Emil Djakov Institute of Electronics, Bulgarian Academy of Sciences, Sofia (Bulgaria); Kovacic, J. [Jozef Stefan Institute, Ljubljana (Slovenia)

    2014-04-15

    This paper reports on probe measurements of the electron energy distribution function and plasma potential in the divertor region of the COMPASS tokamak during D-shaped plasmas. The probe data have been processed using the novel first-derivative technique. A comparison with the results obtained by processing the same data with the classical probe technique, which assumes Maxwellian electron energy distribution functions is presented and discussed. In the vicinity of the inner and outer strike points of the divertor the electron energy distribution function can be approximated by a bi-Maxwellian, with a dominating low-energy electron population (4-7 eV) and a minority of higher energy electrons (12-25 eV). In the private flux region between the two strike points the electron energy distribution function is found to be Maxwellian with temperatures in the range of 7-10 eV. The comparative analysis using both techniques has allowed a better insight into the underlying physical processes at the divertor region of the COMPASS tokamak. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  15. Effect of Mucuna pruriens on semen profile and biochemical parameters in seminal plasma of infertile men.

    Science.gov (United States)

    Ahmad, Mohammad Kaleem; Mahdi, Abbas Ali; Shukla, Kamla Kant; Islam, Najmul; Jaiswar, Shyam Pyari; Ahmad, Sohail

    2008-09-01

    To investigate the impact of Mucuna pruriens seeds on semen profiles and biochemical levels in seminal plasma of infertile men. Prospective study. Departments of Biochemistry and Obstetrics and Gynecology, King George's Medical University, Lucknow, India. Sixty normal healthy fertile men (controls) and 60 men undergoing infertility screening. High-performance liquid chromatography assay procedure for quantitation of vitamin A and E in seminal plasma. Biochemical parameters in seminal plasma, namely lipids, fructose, and vitamin C, were estimated by standard spectrophotometric procedures. Before and after the treatment, seminal plasma lipid profile, lipid peroxide, fructose, and antioxidant vitamin levels were measured. Treatment with M. pruriens significantly inhibited lipid peroxidation, elevated spermatogenesis, and improved sperm motility. Treatment also recovered the levels of total lipids, triglycerides, cholesterol, phospholipids, and vitamin A, C, and E and corrected fructose in seminal plasma of infertile men. Treatment with M. pruriens increased sperm concentration and motility in all the infertile study groups. Oligozoospermic patients recovered sperm concentration significantly, but sperm motility was not restored to normal levels in asthenozoospermic men. Furthermore, in the seminal plasma of all the infertile groups, the levels of lipids, antioxidant vitamins, and corrected fructose were recovered after a decrease in lipid peroxides after treatment. The present study is likely to open new vistas on the possible role of M. pruriens seed powder as a restorative and invigorating agent for infertile men.

  16. Studies on the physico-chemical parameters of Omi water body of ...

    African Journals Online (AJOL)

    In Omi water body, the physico-chemical parameters such as dissolved oxygen ranged from 1.4 to 4.8 mg/L; pH, 6.7 to 7.2; temperature, 26.5 to 31.5°C; alkalinity, 24.2 to 25.4 ppm; conductivity, 23.0 to 28.3 Ohms/cm; turbidity 0.11 to 0.15 m; and free carbon dioxide from 3.5 to 4.5 mg/L. Dissolved oxygen, pH and water ...

  17. The current of a particle along a microtubule in microscopic plasma

    International Nuclear Information System (INIS)

    Li Wei; Chen Junfang; Wang Teng; Lai Xiuqiong

    2008-01-01

    Transport of a particle along the axis of a microtubule in a plasma-enhanced chemical vapor deposition (PECVD) system is investigated. The current, respectively, as a function of the temperature, the magnetic field and the external force is obtained. The value and direction of the current may be controlled by changing the above parameters

  18. In-liquid arc plasma jet and its application to phenol degradation

    KAUST Repository

    Liu, Jing-Lin Lin

    2018-02-07

    We present a new method for achieving chemical reactions induced by plasmas with liquids—an in-liquid arc plasma jet system—designed to have a few advantages over the existing methods. High-speed imaging and optical emission spectroscopy were adopted to highlight the physical aspects of the in-liquid arc plasma jet system, and the feasibility of the system was investigated in a wastewater treatment case with phenol as the model contaminant. We found that the specific energy input is a reasonable parameter by which to characterize the overall process. The phenol removal reaction could be modeled as a pseudo-first-order reaction, and the reaction constant became smaller as the phenol concentration increased. However, complete decomposition of the phenol into water and carbon dioxide required very high energy because the final intermediate, oxalic acid, is relatively stable. Detailed chemical and physical analyses, including byproducts, ions, solution acidity, and conductivity, were conducted to evaluate this new method for use in the appropriate applications.

  19. The Performance Improvement of N2 Plasma Treatment on ZrO2 Gate Dielectric Thin-Film Transistors with Atmospheric Pressure Plasma-Enhanced Chemical Vapor Deposition IGZO Channel.

    Science.gov (United States)

    Wu, Chien-Hung; Huang, Bo-Wen; Chang, Kow-Ming; Wang, Shui-Jinn; Lin, Jian-Hong; Hsu, Jui-Mei

    2016-06-01

    The aim of this paper is to illustrate the N2 plasma treatment for high-κ ZrO2 gate dielectric stack (30 nm) with indium-gallium-zinc-oxide (IGZO) thin-film transistors (TFTs). Experimental results reveal that a suitable incorporation of nitrogen atoms could enhance the device performance by eliminating the oxygen vacancies and provide an amorphous surface with better surface roughness. With N2 plasma treated ZrO2 gate, IGZO channel is fabricated by atmospheric pressure plasma-enhanced chemical vapor deposition (AP-PECVD) technique. The best performance of the AP-PECVD IGZO TFTs are obtained with 20 W-90 sec N2 plasma treatment with field-effect mobility (μ(FET)) of 22.5 cm2/V-s, subthreshold swing (SS) of 155 mV/dec, and on/off current ratio (I(on)/I(off)) of 1.49 x 10(7).

  20. Effect of plasma-induced surface charging on catalytic processes: application to CO2 activation

    Science.gov (United States)

    Bal, Kristof M.; Huygh, Stijn; Bogaerts, Annemie; Neyts, Erik C.

    2018-02-01

    Understanding the nature and effect of the multitude of plasma-surface interactions in plasma catalysis is a crucial requirement for further process development and improvement. A particularly intriguing and rather unique property of a plasma-catalytic setup is the ability of the plasma to modify the electronic structure, and hence chemical properties, of the catalyst through charging, i.e. the absorption of excess electrons. In this work, we develop a quantum chemical model based on density functional theory to study excess negative surface charges in a heterogeneous catalyst exposed to a plasma. This method is specifically applied to investigate plasma-catalytic CO2 activation on supported M/Al2O3 (M = Ti, Ni, Cu) single atom catalysts. We find that (1) the presence of a negative surface charge dramatically improves the reductive power of the catalyst, strongly promoting the splitting of CO2 to CO and oxygen, and (2) the relative activity of the investigated transition metals is also changed upon charging, suggesting that controlled surface charging is a powerful additional parameter to tune catalyst activity and selectivity. These results strongly point to plasma-induced surface charging of the catalyst as an important factor contributing to the plasma-catalyst synergistic effects frequently reported for plasma catalysis.

  1. A Miniaturized Chemical Proteomic Approach for Target Profiling of Clinical Kinase Inhibitors in Tumor Biopsies

    Science.gov (United States)

    Chamrád, Ivo; Rix, Uwe; Stukalov, Alexey; Gridling, Manuela; Parapatics, Katja; Müller, André C.; Altiok, Soner; Colinge, Jacques; Superti-Furga, Giulio; Haura, Eric B.; Bennett, Keiryn L.

    2014-01-01

    While targeted therapy based on the idea of attenuating the activity of a preselected, therapeutically relevant protein has become one of the major trends in modern cancer therapy, no truly specific targeted drug has been developed and most clinical agents have displayed a degree of polypharmacology. Therefore, the specificity of anticancer therapeutics has emerged as a highly important but severely underestimated issue. Chemical proteomics is a powerful technique combining postgenomic drug-affinity chromatography with high-end mass spectrometry analysis and bioinformatic data processing to assemble a target profile of a desired therapeutic molecule. Due to high demands on the starting material, however, chemical proteomic studies have been mostly limited to cancer cell lines. Herein, we report a down-scaling of the technique to enable the analysis of very low abundance samples, as those obtained from needle biopsies. By a systematic investigation of several important parameters in pull-downs with the multikinase inhibitor bosutinib, the standard experimental protocol was optimized to 100 µg protein input. At this level, more than 30 well-known targets were detected per single pull-down replicate with high reproducibility. Moreover, as presented by the comprehensive target profile obtained from miniaturized pull-downs with another clinical drug, dasatinib, the optimized protocol seems to be extendable to other drugs of interest. Sixty distinct human and murine targets were finally identified for bosutinib and dasatinib in chemical proteomic experiments utilizing core needle biopsy samples from xenotransplants derived from patient tumor tissue. Altogether, the developed methodology proves robust and generic and holds many promises for the field of personalized health care. PMID:23901793

  2. An unstructured shock-fitting solver for hypersonic plasma flows in chemical non-equilibrium

    Science.gov (United States)

    Pepe, R.; Bonfiglioli, A.; D'Angola, A.; Colonna, G.; Paciorri, R.

    2015-11-01

    A CFD solver, using Residual Distribution Schemes on unstructured grids, has been extended to deal with inviscid chemical non-equilibrium flows. The conservative equations have been coupled with a kinetic model for argon plasma which includes the argon metastable state as independent species, taking into account electron-atom and atom-atom processes. Results in the case of an hypersonic flow around an infinite cylinder, obtained by using both shock-capturing and shock-fitting approaches, show higher accuracy of the shock-fitting approach.

  3. Bio-compatibility, surface and chemical characterization of glow discharge plasma modified ZnO nanocomposite polycarbonate

    Energy Technology Data Exchange (ETDEWEB)

    Bagra, Bhawna, E-mail: bhawnacct@gmail.com; Pimpliskar, Prashant, E-mail: bhawnacct@gmail.com [Centre for Converging Technologies, University of Rajasthan, Jaipur-302004 (India); Agrawal, Narendra Kumar [Department of Physics, Malaviya National Institute of Technology, Jaipur-302004 (India)

    2014-04-24

    Bio compatibility is an important issue for synthesis of biomedical devices, which can be tested by bioadoptability and creations of active site to enhance the bacterial/cell growth in biomedical devices. Hence a systematic study was carried out to characterize the effects of Nitrogen ion plasma for creations of active site in nano composite polymer membrane. Nano particles of ZnO are synthesized by chemical root, using solution casting nano composite polymeric membranes were prepared and treated with Nitrogen ion plasma. These membranes were characterized by different technique such as optical microscopy, SEM- Scanning electron microscope, optical transmittance, Fourier transform infrared spectroscopy. Then biocompatibility for membranes was tested by testing of bio-adoptability of membrane.

  4. Controlled density of vertically aligned carbon nanotubes in a triode plasma chemical vapor deposition system

    International Nuclear Information System (INIS)

    Lim, Sung Hoon; Park, Kyu Chang; Moon, Jong Hyun; Yoon, Hyun Sik; Pribat, Didier; Bonnassieux, Yvan; Jang, Jin

    2006-01-01

    We report on the growth mechanism and density control of vertically aligned carbon nanotubes using a triode plasma enhanced chemical vapor deposition system. The deposition reactor was designed in order to allow the intermediate mesh electrode to be biased independently from the ground and power electrodes. The CNTs grown with a mesh bias of + 300 V show a density of ∼ 1.5 μm -2 and a height of ∼ 5 μm. However, CNTs do not grow when the mesh electrode is biased to - 300 V. The growth of CNTs can be controlled by the mesh electrode bias which in turn controls the plasma density and ion flux on the sample

  5. Prebiotics, Prosynbiotics and Synbiotics: Can They Reduce Plasma Oxidative Stress Parameters? A Systematic Review.

    Science.gov (United States)

    Salehi-Abargouei, Amin; Ghiasvand, Reza; Hariri, Mitra

    2017-03-01

    This study assessed the effectiveness of presybiotics, prosybiotics and synbiotics on reducing serum oxidative stress parameters. PubMed/Medline, Ovid, Google Scholar, ISI Web of Science and SCOPUS were searched up to September 2016. English language randomized clinical trials reporting the effect of presybiotics, prosybiotics or synbiotic interventions on serum oxidative stress parameters in human adults were included. Twenty-one randomized clinical trials met the inclusion criteria for systematic review. Two studies investigated prebiotics, four studies synbiotics and fifteen studies probiotics. According to our systematic review, prebiotic could decrease malondialdehyde and increase superoxidative dismutase, but evidence is not enough. In comparison with fructo-oligosaccharide, inulin is much more useful for oxidative stress reduction. Using probiotics with dairy products could reduce oxidative stress significantly, but probiotic in form of supplementation did not have any effect on oxidative stress. There is limited but supportive evidence that presybiotics, prosybiotics and synbiotics are effective for reducing oxidative stress parameters. Further randomized clinical trials with longer duration of intervention especially on population with increased oxidative stress are needed to provide more definitive results before any recommendation for clinical use of these interventions.

  6. Topographic, optical and chemical properties of zinc particle coatings deposited by means of atmospheric pressure plasma

    Science.gov (United States)

    Wallenhorst, L. M.; Loewenthal, L.; Avramidis, G.; Gerhard, C.; Militz, H.; Ohms, G.; Viöl, W.

    2017-07-01

    In this research, topographic, optical and chemical properties of zinc oxide layers deposited by a cold plasma-spray process were measured. Here, zinc micro particles were fed to the afterglow of a plasma spark discharge whereas the substrates were placed in a quite cold zone of the effluent plasma jet. In this vein, almost closed layers were realised on different samples. As ascertained by laser scanning and atomic force microscopic measurements the particle size of the basic layer is in the nanometre scale. Additionally, larger particles and agglomerates were found on its top. The results indicate a partial plasma-induced diminishment of the initial particles, most probably due to melting or vaporisation. It is further shown that the plasma gives rise to an increased oxidation of such particles as confirmed by X-ray photoelectron spectroscopy. Quantitative analysis of the resulting mixed layer was performed. It is shown that the deposited layers consist of zinc oxide and elemental zinc in approximately equal shares. In addition, the layer's band gap energy was determined by spectroscopic analysis. Here, considerable UV blocking properties of the deposited layers were observed. Possible underlying effects as well as potential applications are presented.

  7. Fluorination of vertically aligned carbon nanotubes: from CF4 plasma chemistry to surface functionalization.

    Science.gov (United States)

    Struzzi, Claudia; Scardamaglia, Mattia; Colomer, Jean-François; Verdini, Alberto; Floreano, Luca; Snyders, Rony; Bittencourt, Carla

    2017-01-01

    The surface chemistry of plasma fluorinated vertically aligned carbon nanotubes (vCNT) is correlated to the CF 4 plasma chemical composition. The results obtained via FTIR and mass spectrometry are combined with the XPS and Raman analysis of the sample surface showing the dependence on different plasma parameters (power, time and distance from the plasma region) on the resulting fluorination. Photoemission and absorption spectroscopies are used to investigate the evolution of the electronic properties as a function of the fluorine content at the vCNT surface. The samples suffer a limited ageing effect, with a small loss of fluorine functionalities after two weeks in ambient conditions.

  8. Fluorination of vertically aligned carbon nanotubes: from CF4 plasma chemistry to surface functionalization

    Directory of Open Access Journals (Sweden)

    Claudia Struzzi

    2017-08-01

    Full Text Available The surface chemistry of plasma fluorinated vertically aligned carbon nanotubes (vCNT is correlated to the CF4 plasma chemical composition. The results obtained via FTIR and mass spectrometry are combined with the XPS and Raman analysis of the sample surface showing the dependence on different plasma parameters (power, time and distance from the plasma region on the resulting fluorination. Photoemission and absorption spectroscopies are used to investigate the evolution of the electronic properties as a function of the fluorine content at the vCNT surface. The samples suffer a limited ageing effect, with a small loss of fluorine functionalities after two weeks in ambient conditions.

  9. Association of Irisin Plasma Levels with Anthropometric Parameters in Children with Underweight, Normal Weight, Overweight, and Obesity

    Directory of Open Access Journals (Sweden)

    Leticia Elizondo-Montemayor

    2017-01-01

    Full Text Available The correlations between irisin levels, physical activity, and anthropometric measurements have been extensively described in adults with considerable controversy, but little evidence about these relationships has been found in children. The objective of this study is to correlate the plasma levels of irisin in underweight, normal weight, overweight, and obese children with anthropometric parameters and physical activity levels. A cross-sample of 40 children was divided into the following groups on the basis of body mass index (BMI percentile. The correlations of plasma irisin levels with physical activity, anthropometric, and metabolic measurements were determined. Plasma irisin levels (ng/mL were lower for the underweight group (164.2 ± 5.95 than for the normal weight and obese groups (182.8 ± 5.58; p<0.05. Irisin levels correlated positively with BMI percentile (0.387, waist circumference (0.373, and fat-free mass (0.353; p<0.05, but not with body muscle mass (−0.027. After a multiple linear regression analysis, only BMI percentile (0.564; p<0.008 showed a positive correlation with irisin. Our results indicated no association with metabolic parameters. A negative correlation with physical activity was observed. Interrelationships among body components might influence irisin levels in children.

  10. Plasma treatment of polypropylene fabric for improved dyeability with soluble textile dyestuff

    International Nuclear Information System (INIS)

    Yaman, Necla; Ozdogan, Esen; Seventekin, Necdet; Ayhan, Hakan

    2009-01-01

    The impact of plasma treatment parameters on the surface morphology, physical-chemical, and dyeing properties of polypropylene (PP) using anionic and cationic dyestuffs were investigated in this study. Argon plasma treatment was used to activate PP fabric surfaces. Activated surfaces were grafted different compounds: 6-aminohexanoic acid (6-AHA), acrylic acid (AA), ethylendiamine (EDA), acryl amide (AAMID) and hexamethyldisiloxane (HMDS). Compounds were applied after the plasma treatment and the acid and basic dyeing result that was then observed, were quite encouraging in certain conditions. The possible formed oxidizing groups were emphasized by FTIR and ATR and the surface morphology of plasma treated PP fibers was also investigated with scanning electron microscopy (SEM). PP fabric could be dyed with acid and basic dyestuffs after only plasma treatment and plasma induced grafting, and fastnesses of the dyed samples were satisfactory.

  11. Modeling of Sheath Ion-Molecule Reactions in Plasma Enhanced Chemical Vapor Deposition of Carbon Nanotubes

    Science.gov (United States)

    Hash, David B.; Govindan, T. R.; Meyyappan, M.

    2004-01-01

    In many plasma simulations, ion-molecule reactions are modeled using ion energy independent reaction rate coefficients that are taken from low temperature selected-ion flow tube experiments. Only exothermic or nearly thermoneutral reactions are considered. This is appropriate for plasma applications such as high-density plasma sources in which sheaths are collisionless and ion temperatures 111 the bulk p!asma do not deviate significantly from the gas temperature. However, for applications at high pressure and large sheath voltages, this assumption does not hold as the sheaths are collisional and ions gain significant energy in the sheaths from Joule heating. Ion temperatures and thus reaction rates vary significantly across the discharge, and endothermic reactions become important in the sheaths. One such application is plasma enhanced chemical vapor deposition of carbon nanotubes in which dc discharges are struck at pressures between 1-20 Torr with applied voltages in the range of 500-700 V. The present work investigates The importance of the inclusion of ion energy dependent ion-molecule reaction rates and the role of collision induced dissociation in generating radicals from the feedstock used in carbon nanotube growth.

  12. Chemical-physical parameters of atmospheric precipitations in the Pisa urban area

    International Nuclear Information System (INIS)

    Paradossi, C.; Marchini, F.

    1998-01-01

    In the work the major chemical-physical parameters of the rain collected in May 1992 - May 1993 period in Pisa are studied and discussed. The ph analysis was particular interesting. Indeed sometimes it reached values between 4.5 and 5.0. Also the ions examined although they did not reach values supposed to cause damage, were subjected to monthly variations. This paper confirms previously results. Pisa although not being considered an industrial area is subjected to pollutant acid rains [it

  13. Vertically aligned Si nanocrystals embedded in amorphous Si matrix prepared by inductively coupled plasma chemical vapor deposition (ICP-CVD)

    Energy Technology Data Exchange (ETDEWEB)

    Nogay, G. [Department of Physics, Middle East Technical University (METU), Ankara 06800 (Turkey); Center of Solar Energy Research and Application (GÜNAM), Middle East Technical University (METU), Ankara 06800 (Turkey); Saleh, Z.M., E-mail: zaki.saleh@aauj.edu [Center of Solar Energy Research and Application (GÜNAM), Middle East Technical University (METU), Ankara 06800 (Turkey); Department of Physics, Arab American University–Jenin (AAUJ), Jenin, Palestine (Country Unknown); Özkol, E. [Center of Solar Energy Research and Application (GÜNAM), Middle East Technical University (METU), Ankara 06800 (Turkey); Department of Chemical Engineering, Middle East Technical University (METU), Ankara 06800 (Turkey); Turan, R. [Department of Physics, Middle East Technical University (METU), Ankara 06800 (Turkey); Center of Solar Energy Research and Application (GÜNAM), Middle East Technical University (METU), Ankara 06800 (Turkey)

    2015-06-15

    Highlights: • Inductively-coupled plasma is used for nanostructured silicon at room temperature. • Low temperature deposition allows device processing on various substrates. • Deposition pressure is the most effective parameter in controlling nanostructure. • Films consist of quantum dots in a-Si matrix and exhibit columnar vertical growth. • Films are porous to oxygen infusion along columnar grain boundaries. - Abstract: Vertically-aligned nanostructured silicon films are deposited at room temperature on p-type silicon wafers and glass substrates by inductively-coupled, plasma-enhanced chemical vapor deposition (ICPCVD). The nanocrystalline phase is achieved by reducing pressure and increasing RF power. The crystalline volume fraction (X{sub c}) and the size of the nanocrystals increase with decreasing pressure at constant power. Columnar growth of nc-Si:H films is observed by high resolution transmission electron microscopy (HRTEM) and scanning electron microscopy (SEM). The films exhibit cauliflower-like structures with high porosity that leads to slow but uniform oxidation after exposure to air at room temperature. Films deposited at low pressures exhibit photoluminescence (PL) signals that may be deconvoluted into three distinct Gaussian components: 760–810, 920–935, and 990–1000 nm attributable to the quantum confinement and interface defect states. Hydrogen dilution is manifested in significant enhancement of the PL, but it has little effect on the nanocrystal size and X{sub c}.

  14. Spectroscopic ellipsometry characterization of nano-crystalline diamondfilms prepared at various substrate temperatures and pulsed plasma frequencies using microwave plasma enhanced chemical vapor deposition apparatus with linear antenna delivery

    Czech Academy of Sciences Publication Activity Database

    Mistrík, J.; Janíček, P.; Taylor, Andrew; Fendrych, František; Fekete, Ladislav; Jäger, Aleš; Nesládek, M.

    2014-01-01

    Roč. 571, č. 1 (2014), s. 230-237 ISSN 0040-6090 R&D Projects: GA ČR GA13-31783S; GA MŠk(CZ) LM2011026 Grant - others: COST Nano TP(XE) MP0901; OP VK(XE) CZ.1.07/2.3.00/20.0306 Institutional support: RVO:68378271 Keywords : nanocrystalline diamond * thin films * microwave plasma-enhanced chemical vapor deposition * pulsed plasma * low deposition temperature Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.759, year: 2014

  15. Non-thermal atmospheric pressure HF plasma source: generation of nitric oxide and ozone for bio-medical applications

    Science.gov (United States)

    Kühn, S.; Bibinov, N.; Gesche, R.; Awakowicz, P.

    2010-01-01

    A new miniature high-frequency (HF) plasma source intended for bio-medical applications is studied using nitrogen/oxygen mixture at atmospheric pressure. This plasma source can be used as an element of a plasma source array for applications in dermatology and surgery. Nitric oxide and ozone which are produced in this plasma source are well-known agents for proliferation of the cells, inhalation therapy for newborn infants, disinfection of wounds and blood ozonation. Using optical emission spectroscopy, microphotography and numerical simulation, the gas temperature in the active plasma region and plasma parameters (electron density and electron distribution function) are determined for varied nitrogen/oxygen flows. The influence of the gas flows on the plasma conditions is studied. Ozone and nitric oxide concentrations in the effluent of the plasma source are measured using absorption spectroscopy and electro-chemical NO-detector at variable gas flows. Correlations between plasma parameters and concentrations of the particles in the effluent of the plasma source are discussed. By varying the gas flows, the HF plasma source can be optimized for nitric oxide or ozone production. Maximum concentrations of 2750 ppm and 400 ppm of NO and O3, correspondingly, are generated.

  16. Plasma-enhanced chemical vapor deposited silicon oxynitride films for optical waveguide bridges for use in mechanical sensors

    DEFF Research Database (Denmark)

    Storgaard-Larsen, Torben; Leistiko, Otto

    1997-01-01

    In this paper the influence of RF power, ammonia flow, annealing temperature, and annealing time on the optical and mechanical properties of plasma-enhanced chemically vapor deposited silicon oxynitride films, is presented. A low refractive index (1.47 to 1.48) film having tensile stress has been...

  17. Hot plasma parameters in Neptune's magnetosphere

    International Nuclear Information System (INIS)

    Krimigis, S.M.; Mauk, B.H.; Cheng, A.F.; Keath, E.P.; Kane, M.; Armstrong, T.P.; Gloeckler, G.; Lanzerotti, L.J.

    1990-01-01

    Energy spectra of energetic protons and electrons (E p approx-gt 28 keV, E e approx-gt 22 keV, respectively) obtained with the Low Energy Charged Particle (LECP) instrument during the Voyager 2 encounter with Neptune on August 24-25, 1989 are presented. The proton spectral form was a power law (dj/dE = KE -γ ), outside the orbit of Triton (∼14.3 R N ); inside that distance, it was found to be a hot (kT ≅ 60 keV) Maxwellian distribution. Such distributions, observed in other planets as well, have yet to be explained theoretically. Similarly, the electron spectral form changed from a simple power law outside Triton to a two-slope power law with a high energy tail inside. Intensity and spectral features in both proton and electron fluxes were identified in association with the crossings of the Triton and 1989 N1 L-shells, but these features do not occur simultaneously in both species. Such signatures were manifested by relative peaks in both kT and γ spectral indices. Peak proton pressures of ∼2x10 -9 dynes cm -2 , and β ∼ 0.2 were measured at successive magnetic equatorial crossings, both inbound and outbound. These parameters show Neptune's magnetosphere to be relatively undistorted by hot plasma loading, similar to that of Uranus and unlike those of Saturn and Jupiter. Trapped electron fluxes at Neptune, as at Uranus, exceed the whistler mode stably trapped flux limit. Whistler-induced pitch angle scattering of energetic electrons in the radiation belts can yield a precipitating energy flux sufficient to drive Neptune's aurora

  18. Double plasma system with inductively coupled source plasma and quasi-quiescent target plasma

    International Nuclear Information System (INIS)

    Massi, M.; Maciel, H.S.

    1995-01-01

    Cold plasmas have successfully been used in the plasma-assisted material processing industry. An understanding of the physicochemical mechanisms involved in the plasma-surface interaction is needed for a proper description of deposition and etching processes at material surfaces. Since these mechanisms are dependent on the plasma properties, the development of diagnostic techniques is strongly desirable for determination of the plasma parameters as well as the characterization of the electromagnetic behaviour of the discharge. In this work a dual discharge chamber, was specially designed to study the deposition of thin films via plasma polymerization process. In the Pyrex chamber an inductively coupled plasma can be excited either in the diffuse low density E-mode or in the high density H-mode. This plasma diffuses into the cylindrical stainless steel chamber which is covered with permanent magnets to produce a multidipole magnetic field configuration at the surface. By that means a double plasma is established consisting of a RF source plasma coupled to a quasi-quiescent target plasma. The preliminary results presented here refer to measurements of the profiles of plasma parameters along the central axis of the double plasma apparatus. Additionally a spectrum analysis performed by means of a Rogowski coil probe immersed into the source plasma is also presented. The discharge is made in argon with pressure varying from 10 -2 to 1 torr, and the rf from 10 to 150 W

  19. Physico-chemical and bacteriological parameters in a hypereutrophic lagoon (Albufera Lake, Valencia, Spain).

    Science.gov (United States)

    Aznar, R; Amaro, C; Garay, E; Alcaide, E

    1991-01-01

    Several physico-chemical parameters related to water quality, as well as saprophytic and public health-related heterotrophic bacterial groups were studied in a hypereutrophic lake (Albufera, Valencia) at different seasons. Total microscopic and viable counts were compared, and, together with faecal indicators, were determined in water samples from different sites. Heterotrophic bacteria grown on nonselective medium were identified to genus level and a diversity index was calculated. Pseudomonas-Alcaligenes was the most frequently isolated group from all sampling sites along the study, following by Moraxella, Acinetobacter, Vibrio and Aeromonas. The relationships between all parameters were searched by Principal Components Analysis (PCA).

  20. THE EFFECT OF SELECTED PHYSICAL AND CHEMICAL PARAMETERS ON MICROBIOLOGICAL STATUS OF THE VISTULA RIVER NEAR WARSAW

    Directory of Open Access Journals (Sweden)

    Janusz Augustynowicz

    2016-02-01

    Full Text Available The types of organisms present in water reservoirs depend on water purity and biochemical processes that occur. Therefore, one of the methods of water quality assessment is to determine its condition by determining the biological indicators, including microbiological parameters. The aim of the experiment presented in this paper was to investigate the effects of selected physical and chemical parameters of water samples from the Vistula River on the microbiological status of water. The experiment was conducted in water samples collected in the central part of the Vistula River in Warsaw. The analyses of selected parameters were performed once a month throughout the year. Microbiological tests included: number of nitrogen fixing bacteria, MPN nitrifying bacteria, MPN sulfate-reducing bacteria. Physical and chemical parameters such as temperature, pH and total nitrogen content were determined in water samples. The results showed a correlation between temperature, pH and microbiological parameters. However, there was no significant correlation between the number of tested microorganisms and the concentration of total nitrogen in water samples.

  1. Correlation of salivary immunoglobulin A against lipopolysaccharide of Porphyromonas gingivalis with clinical periodontal parameters

    Directory of Open Access Journals (Sweden)

    Pushpa S Pudakalkatti

    2015-01-01

    Full Text Available Background: A major challenge in clinical periodontics is to find a reliable molecular marker of periodontal tissue destruction. Aim: The aim of the present study was to assess, whether any correlation exists between salivary immunoglobulin A (IgA level against lipopolysaccharide of Porphyromonas gingivalis and clinical periodontal parameters (probing depth and clinical attachment loss. Materials and Methods: Totally, 30 patients with chronic periodontitis were included for the study based on clinical examination. Unstimulated saliva was collected from each study subject. Probing depth and clinical attachment loss were recorded in all selected subjects using University of North Carolina-15 periodontal probe. Extraction and purification of lipopolysaccharide were done from the standard strain of P. gingivalis (ATCC 33277. Enzyme linked immunosorbent assay (ELISA was used to detect the level of IgA antibodies against lipopolysaccharide of P. gingivalis in the saliva of each subject by coating wells of ELISA kit with extracted lipopolysaccharide antigen. Statistical Analysis: The correlation between salivary IgA and clinical periodontal parameters was checked using Karl Pearson′s correlation coefficient method and regression analysis. Results: The significant correlation was observed between salivary IgA level and clinical periodontal parameters in chronic periodontitis patients. Conclusion: A significant strong correlation was observed between salivary IgA against lipopolysaccharide of P. gingivalis and clinical periodontal parameters which suggest that salivary IgA level against lipopolysaccharide of P. gingivalis can be used to predict the severity of periodontal destruction in chronic periodontitis patients.

  2. Application of cation-exchange solid-phase extraction for the analysis of amino alcohols from water and human plasma for verification of Chemical Weapons Convention.

    Science.gov (United States)

    Kanaujia, Pankaj K; Tak, Vijay; Pardasani, Deepak; Gupta, A K; Dubey, D K

    2008-03-28

    The analysis of nitrogen containing amino alcohols, which are the precursors and degradation products of nitrogen mustards and nerve agent VX, constitutes an important aspect for verifying the compliance to the CWC (Chemical Weapons Convention). This work devotes on the development of solid-phase extraction method using silica- and polymer-based SCX (strong cation-exchange) and MCX (mixed-mode strong cation-exchange) cartridges for N,N-dialkylaminoethane-2-ols and alkyl N,N-diethanolamines, from water. The extracted analytes were analyzed by GC-MS (gas chromatography-mass spectrometry) in the full scan and selected ion monitoring modes. The extraction efficiencies of SCX and MCX cartridges were compared, and results revealed that SCX performed better. Extraction parameters, such as loading capacity, extraction solvent, its volume, and washing solvent were optimized. Best recoveries were obtained using 2 mL methanol containing 10% NH(4)OH and limits of detection could be achieved up to 5 x 10(-3) microg mL(-1) in the selected ion monitoring mode and 0.01 microg mL(-1) in full scan mode. The method was successfully employed for the detection and identification of amino alcohol present in water sample sent by Organization for Prohibition of Chemical Weapons (OPCW) in the official proficiency tests. The method was also applied to extract the analytes from human plasma. The SCX cartridge showed good recoveries of amino alcohols from human plasma after protein precipitation.

  3. Applied parameter estimation for chemical engineers

    CERN Document Server

    Englezos, Peter

    2000-01-01

    Formulation of the parameter estimation problem; computation of parameters in linear models-linear regression; Gauss-Newton method for algebraic models; other nonlinear regression methods for algebraic models; Gauss-Newton method for ordinary differential equation (ODE) models; shortcut estimation methods for ODE models; practical guidelines for algorithm implementation; constrained parameter estimation; Gauss-Newton method for partial differential equation (PDE) models; statistical inferences; design of experiments; recursive parameter estimation; parameter estimation in nonlinear thermodynam

  4. A study of evolution/suppression parameters of equatorial postsunset plasma instability

    Directory of Open Access Journals (Sweden)

    O. S. Oyekola

    2009-01-01

    Full Text Available Evening equatorial pre-reversal vertical ion E×B drift (VZP and the peak of the ionospheric F2 maximum altitude (hmF2P of the postsunset equatorial F-layer, which are the essential parameters requisite for the generation or inhibition of postsunset bottomside equatorial irregularities were deduced from ionosonde observations made in the Africa region (Ouagadougou: ~3° N dip latitude between January 1987 and December 1990 for solar activity minimum, medium, and maxima (F10.7=85, 141, 214, and 190, respectively for quiet geomagnetic conditions. We investigate variations of evening equatorial pre-reversal drift and the corresponding altitude at four levels of solar activity. Our observations show strong variations with solar variability. Correlation analysis between these parameters indicates that the correlation coefficient value between hmF2P versus VZP decreases considerably with increasing solar flux value. There seems to be no significant link between these parameters under high solar activity, especially for solar intensity F10.7>200 units. We conclude that meridional neutral wind in the F-region contributes substantially to the variations of the pre-reversal vertical plasma drifts enhancement and the peak hmF2, particularly the electrodynamics during twilight high solar flux conditions.

  5. Determination of trapping parameters and the chemical diffusion coefficient from hydrogen permeation experiments

    International Nuclear Information System (INIS)

    Svoboda, J.; Mori, G.; Prethaler, A.; Fischer, F.D.

    2014-01-01

    Highlights: • A modeling study for diffusion of hydrogen with traps is presented. • Introduction of a new chemical diffusion coefficient. • Density of traps and average depth of traps can be determined. • Lattice diffusion and sub-surface concentration of atomic hydrogen can be determined. - Abstract: An improved diffusion theory accounting for trapping effects is applied to evaluation of hydrogen permeation experiments performed for pure iron and pearlitic and martensitic steels. The trapping parameters as molar volume and depth of traps are determined by fitting experiments by simulations based on the theory. The concentration-dependent chemical diffusion coefficient of hydrogen is extracted indicating that the trapping effect on diffusion in pure iron and pearlitic steel is negligible. However, it is significant for martensitic steel, for which the chemical diffusion coefficient cannot be considered as concentration-independent as it is established in current standards

  6. Wearable Atmospheric Pressure Plasma Fabrics Produced by Knitting Flexible Wire Electrodes for the Decontamination of Chemical Warfare Agents

    Science.gov (United States)

    Jung, Heesoo; Seo, Jin Ah; Choi, Seungki

    2017-01-01

    One of the key reasons for the limited use of atmospheric pressure plasma (APP) is its inability to treat non-flat, three-dimensional (3D) surface structures, such as electronic devices and the human body, because of the rigid electrode structure required. In this study, a new APP system design—wearable APP (WAPP)—that utilizes a knitting technique to assemble flexible co-axial wire electrodes into a large-area plasma fabric is presented. The WAPP device operates in ambient air with a fully enclosed power electrode and grounded outer electrode. The plasma fabric is flexible and lightweight, and it can be scaled up for larger areas, making it attractive for wearable APP applications. Here, we report the various plasma properties of the WAPP device and successful test results showing the decontamination of toxic chemical warfare agents, namely, mustard (HD), soman (GD), and nerve (VX) agents.

  7. Apparatus for chemical synthesis

    Science.gov (United States)

    Kong, Peter C [Idaho Falls, ID; Herring, J Stephen [Idaho Falls, ID; Grandy, Jon D [Idaho Falls, ID

    2011-05-10

    A method and apparatus for forming a chemical hydride is described and which includes a pseudo-plasma-electrolysis reactor which is operable to receive a solution capable of forming a chemical hydride and which further includes a cathode and a movable anode, and wherein the anode is moved into and out of fluidic, ohmic electrical contact with the solution capable of forming a chemical hydride and which further, when energized produces an oxygen plasma which facilitates the formation of a chemical hydride in the solution.

  8. Chemical and microstructural characterizations of plasma polymer films by time-of-flight secondary ion mass spectrometry and principal component analysis

    International Nuclear Information System (INIS)

    Cossement, Damien; Renaux, Fabian; Thiry, Damien; Ligot, Sylvie; Francq, Rémy; Snyders, Rony

    2015-01-01

    Graphical abstract: - Highlights: • Plasma polymer films have a chemical selectivity and a cross-linking degree which are known to vary in opposite trends. • Three plasma polymers families were used as model organic layers for cross-linking evaluation by ToF-SIMS and principal component analysis. • The data were cross-checked with related functional properties that are known to depend on the cross-linking degree (stability in solvent, mechanical properties, …). • The suggested cross-linking evaluation method was validated for different families of plasma polymers demonstrating that it can be seen as a “general” method. - Abstract: It is accepted that the macroscopic properties of functional plasma polymer films (PPF) are defined by their functional density and their crosslinking degree (χ) which are quantities that most of the time behave in opposite trends. If the PPF chemistry is relatively easy to evaluate, it is much more challenging for χ. This paper reviews the recent work developed in our group on the application of principal component analysis (PCA) to time-of-flight secondary ion mass spectrometric (ToF-SIMS) positive spectra data in order to extract the relative cross-linking degree (χ) of PPF. NH_2-, COOR- and SH-containing PPF synthesized in our group by plasma enhanced chemical vapor deposition (PECVD) varying the applied radiofrequency power (P_R_F), have been used as model surfaces. For the three plasma polymer families, the scores of the first computed principal component (PC1) highlighted significant differences in the chemical composition supported by X-Ray photoelectron spectroscopy (XPS) data. The most important fragments contributing to PC1 (loadings > 90%) were used to compute an average C/H ratio index for samples synthesized at low and high P_R_F. This ratio being an evaluation of χ, these data, accordingly to the literature, indicates an increase of χ with P_R_F excepted for the SH-PPF. These results have been cross

  9. Chemical and microstructural characterizations of plasma polymer films by time-of-flight secondary ion mass spectrometry and principal component analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cossement, Damien, E-mail: damien.cossement@materianova.be [Materia Nova Research Center, Parc Initialis, 1, Avenue Nicolas Copernic, B-7000 Mons (Belgium); Renaux, Fabian [Materia Nova Research Center, Parc Initialis, 1, Avenue Nicolas Copernic, B-7000 Mons (Belgium); Thiry, Damien; Ligot, Sylvie [Chimie des Interactions Plasma-Surface (ChIPS), CIRMAP, Université de Mons, 23 Place du Parc, B-7000 Mons (Belgium); Francq, Rémy; Snyders, Rony [Materia Nova Research Center, Parc Initialis, 1, Avenue Nicolas Copernic, B-7000 Mons (Belgium); Chimie des Interactions Plasma-Surface (ChIPS), CIRMAP, Université de Mons, 23 Place du Parc, B-7000 Mons (Belgium)

    2015-11-15

    Graphical abstract: - Highlights: • Plasma polymer films have a chemical selectivity and a cross-linking degree which are known to vary in opposite trends. • Three plasma polymers families were used as model organic layers for cross-linking evaluation by ToF-SIMS and principal component analysis. • The data were cross-checked with related functional properties that are known to depend on the cross-linking degree (stability in solvent, mechanical properties, …). • The suggested cross-linking evaluation method was validated for different families of plasma polymers demonstrating that it can be seen as a “general” method. - Abstract: It is accepted that the macroscopic properties of functional plasma polymer films (PPF) are defined by their functional density and their crosslinking degree (χ) which are quantities that most of the time behave in opposite trends. If the PPF chemistry is relatively easy to evaluate, it is much more challenging for χ. This paper reviews the recent work developed in our group on the application of principal component analysis (PCA) to time-of-flight secondary ion mass spectrometric (ToF-SIMS) positive spectra data in order to extract the relative cross-linking degree (χ) of PPF. NH{sub 2}-, COOR- and SH-containing PPF synthesized in our group by plasma enhanced chemical vapor deposition (PECVD) varying the applied radiofrequency power (P{sub RF}), have been used as model surfaces. For the three plasma polymer families, the scores of the first computed principal component (PC1) highlighted significant differences in the chemical composition supported by X-Ray photoelectron spectroscopy (XPS) data. The most important fragments contributing to PC1 (loadings > 90%) were used to compute an average C/H ratio index for samples synthesized at low and high P{sub RF}. This ratio being an evaluation of χ, these data, accordingly to the literature, indicates an increase of χ with P{sub RF} excepted for the SH-PPF. These results have

  10. Consensus guidelines on plasma cell myeloma minimal residual disease analysis and reporting.

    Science.gov (United States)

    Arroz, Maria; Came, Neil; Lin, Pei; Chen, Weina; Yuan, Constance; Lagoo, Anand; Monreal, Mariela; de Tute, Ruth; Vergilio, Jo-Anne; Rawstron, Andy C; Paiva, Bruno

    2016-01-01

    Major heterogeneity between laboratories in flow cytometry (FC) minimal residual disease (MRD) testing in multiple myeloma (MM) must be overcome. Cytometry societies such as the International Clinical Cytometry Society and the European Society for Clinical Cell Analysis recognize a strong need to establish minimally acceptable requirements and recommendations to perform such complex testing. A group of 11 flow cytometrists currently performing FC testing in MM using different instrumentation, panel designs (≥ 6-color) and analysis software compared the procedures between their respective laboratories and reviewed the literature to propose a consensus guideline on flow-MRD analysis and reporting in MM. Consensus guidelines support i) the use of minimum of five initial gating parameters (CD38, CD138, CD45, forward, and sideward light scatter) within the same aliquot for accurate identification of the total plasma cell compartment; ii) the analysis of potentially aberrant phenotypic markers and to report the antigen expression pattern on neoplastic plasma cells as being reduced, normal or increased, when compared to a normal reference plasma cell immunophenotype (obtained using the same instrument and parameters); and iii) the percentage of total bone marrow plasma cells plus the percentages of both normal and neoplastic plasma cells within the total bone marrow plasma cell compartment, and over total bone marrow cells. Consensus guidelines on minimal current and future MRD analyses should target a lower limit of detection of 0.001%, and ideally a limit of quantification of 0.001%, which requires at least 3 × 10(6) and 5 × 10(6) bone marrow cells to be measured, respectively. © 2015 International Clinical Cytometry Society.

  11. Evaporation of carbon using electrons of a high density plasma; Evaporacion de carbono usando los electrones de un plasma de alta densidad

    Energy Technology Data Exchange (ETDEWEB)

    Muhl, S.; Camps, E.; Escobar A, L.; Garcia E, J.L.; Olea, O. [Instituto de Investigaciones en Materiales, UNAM, C.P. 04510 Mexico D.F. (Mexico)

    2000-07-01

    The high density plasmas are used frequently in the preparation of thin films or surface modification, for example to nitridation. In these processes, are used mainly the ions and the neutrals which compose the plasma. However, the electrons present in the plasma are not used, except in the case of chemical reactions induced by collisions, although the electron bombardment usually get hot the work piece. Through the adequate polarization of a conductor material, it is possible to extract electrons from a high density plasma at low pressure, that could be gotten the evaporation of this material. As result of the interaction between the plasma and the electron flux with the vapor produced, this last will be ionized. In this work, it is reported the use of this novelty arrangement to prepare carbon thin films using a high density argon plasma and a high purity graphite bar as material to evaporate. It has been used substrates outside plasma and immersed in the plasma. Also it has been reported the plasma characteristics (temperature and electron density, energy and ions flux), parameters of the deposit process (deposit rate and ion/neutral rate) as well as the properties of the films obtained (IR absorption spectra and UV/Vis, elemental analysis, hardness and refractive index). (Author)

  12. Mercury-free electrodeless discharge lamp: effect of xenon pressure and plasma parameters on luminance

    International Nuclear Information System (INIS)

    Nazri Dagang Ahmad; Kondo, Akira; Motomura, Hideki; Jinno, Masafumi

    2009-01-01

    Since there is much concern about environmental preservation, the authors have paid attention to the uses of mercury in lighting application. They have focused on the application of the xenon low-pressure inductively coupled plasma (ICP) discharge in developing cylindrical type mercury-free light sources. ICP can be operated at low filling gas pressures and demonstrates significant potential in producing high density plasma. Xenon pressure was varied from 0.1 to 100 Torr and the lamp luminance was measured. The gas pressure dependence shows an increase in luminance at pressures below 1 Torr. In order to clarify this behaviour, measurement of plasma parameters was carried out using the double probe method and its relation to lamp luminance is discussed. As the gas pressure is decreased (from 1 to 0.01 Torr), the electron temperature increases while the electron density decreases while at the same time the lamp luminance increases. There are several factors that are believed to contribute to the increase in luminance in the very low pressure region. Increases in luminance are considered to be due to the electron-ion recombination process which brings a strong recombination radiation in continuum in the visible region and also due to the effect of stochastic heating.

  13. Microwave plasma enhanced chemical vapor deposition growth of few-walled carbon nanotubes using catalyst derived from an iron-containing block copolymer precursor

    International Nuclear Information System (INIS)

    Wang Peng; Lu, Jennifer; Zhou, Otto

    2008-01-01

    The microwave plasma enhanced chemical vapor deposition (MPECVD) method is now commonly used for directional and conformal growth of carbon nanotubes (CNTs) on supporting substrates. One of the shortcomings of the current process is the lack of control of the diameter and diameter distribution of the CNTs due to difficulties in synthesizing well-dispersed catalysts. Recently, block copolymer derived catalysts have been developed which offer the potential of fine control of both the size of and the spacing between the metal clusters. In this paper we report the successful growth of CNTs with narrow diameter distribution using polystyrene-block-polyferrocenylethylmethylsilane (PS-b-PFEMS) as the catalyst precursor. The study shows that higher growth pressure leads to better CNT growth. Besides the pressure, the effects on the growth of CNTs of the growth parameters, such as temperature and precursor gas ratio, are also studied

  14. Derivation of cell population kinetic parameters from clinical statistical data (program RAD3)

    International Nuclear Information System (INIS)

    Cohen, L.

    1978-01-01

    Cellular lethality models generally require up to 6 parameters to simulate a clinical course of fractionated radiation therapy and to derive an estimate of the cellular surviving fraction for a given treatment scheme. These parameters are the mean cellular lethal dose, the extrapolation number, the ratio of sublethal to irreparable events, the regeneration rate, the repopulation limit (cell cycles), and a field-size or tumor-volume factor. A computer program (RAD3) was designed to derive best-fitting values for these parameters in relation to available clinical data based on the assumption that if a number of different fractionation schemes yield similar reactions, the cellular surviving fractions will be about equal in each instance. Parameters were derived for a variety of human tissues from which realistic iso-effect functions could be generated

  15. Short-term biological variation of clinical chemical values in dumeril's monitors (Varanus dumerili)

    DEFF Research Database (Denmark)

    Bertelsen, Mads Frost; Kjelgaard-Hansen, Mads Jens; Howell, Jennifer R.

    2007-01-01

    Plasma biochemical values are routinely used in the medical management of ill reptiles, and for monitoring the health of clinically normal animals. Laboratory tests, including clinical biochemical values, are subject to biological and analytical variation, the magnitude of which determines the ut...

  16. Nitrogen Fixation by Gliding Arc Plasma: Better Insight by Chemical Kinetics Modelling.

    Science.gov (United States)

    Wang, Weizong; Patil, Bhaskar; Heijkers, Stjin; Hessel, Volker; Bogaerts, Annemie

    2017-05-22

    The conversion of atmospheric nitrogen into valuable compounds, that is, so-called nitrogen fixation, is gaining increased interest, owing to the essential role in the nitrogen cycle of the biosphere. Plasma technology, and more specifically gliding arc plasma, has great potential in this area, but little is known about the underlying mechanisms. Therefore, we developed a detailed chemical kinetics model for a pulsed-power gliding-arc reactor operating at atmospheric pressure for nitrogen oxide synthesis. Experiments are performed to validate the model and reasonable agreement is reached between the calculated and measured NO and NO 2 yields and the corresponding energy efficiency for NO x formation for different N 2 /O 2 ratios, indicating that the model can provide a realistic picture of the plasma chemistry. Therefore, we can use the model to investigate the reaction pathways for the formation and loss of NO x . The results indicate that vibrational excitation of N 2 in the gliding arc contributes significantly to activating the N 2 molecules, and leads to an energy efficient way of NO x production, compared to the thermal process. Based on the underlying chemistry, the model allows us to propose solutions on how to further improve the NO x formation by gliding arc technology. Although the energy efficiency of the gliding-arc-based nitrogen fixation process at the present stage is not comparable to the world-scale Haber-Bosch process, we believe our study helps us to come up with more realistic scenarios of entering a cutting-edge innovation in new business cases for the decentralised production of fertilisers for agriculture, in which low-temperature plasma technology might play an important role. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Influence of laser design parameters on the hydrodynamics of microfusion plasmas; Influencia de los parametros basicos del laser sobre la hidrodinamica de plasmas para microfusion

    Energy Technology Data Exchange (ETDEWEB)

    Sanmartin, J A; Barrero, A

    1976-07-01

    The quasi neutral, one dimensional motion generated in a cold, infinite, uniform plasma of density n{sub 0}, by the absorption, In a given plane, of a linear pulse of energy per unit time and area {phi} - {phi}{sub 0}t/{tau}, 0< t {<=} {tau}, is considered; the analysis allows for thermal conduction and viscosity of ions and electrons, their energy exchange, and an electron thermal flux limiter. The motion is found to be self similar and governed by single non dimensional parameter {alpha} similar{sub t}o(n{sup 2}{sub 0} {tau}/{phi}{sub 0}){sup 2}/3. Detailed asymptotic results are obtained for both {alpha}<<1and {alpha}>>1; the general (behaviour of the solution for arbitrary {alpha} is discussed. The analysis can be easily extended to the case of a plasma initially occupying a half-space, and throws light on the hydrodynamics of laser fusion plasmas. (Author) 51 refs.

  18. Wettability and XPS analyses of nickel–phosphorus surfaces after plasma treatment: An efficient approach for surface qualification in mechatronic processes

    International Nuclear Information System (INIS)

    Vivet, L.; Joudrier, A.-L.; Bouttemy, M.; Vigneron, J.; Tan, K.L.; Morelle, J.M.; Etcheberry, A.; Chalumeau, L.

    2013-01-01

    Electroless nickel-high-phosphorus Ni–P plating is known for its physical properties. In case of electronic and mechatronic assembly processes achieved under ambient conditions the wettability of the Ni–P layer under ambient temperature and ambient air stays a point of surface quality investigation. This contribution will be devoted to the study of the surface properties of Ni–P films for which we performed air plasma treatment. We focus our attention on the evolution of the surface wettability, using the classical sessile drop technique. Interpreting the results with the OWRK model we extract the polar and disperse surface tension components from which we deduced typical evolution of the surface properties with the different treatment settings. By controlling the variations of the parameters of the plasma exposure we are able to change the responses of our Ni–P sample from total hydrophobic to total hydrophilic behaviours. All the intermediate states can be reached by adapting the treatment parameters. So it is demonstrated that the apparent Ni–P surface properties can be fully adapted and the surface setting can be well characterized by wettability measurements. To deep our knowledge of the surface modifications induced by plasma we performed parallel SEM and XPS analyses which provide informations on the structure and the chemical composition of the surface for each set of treatment parameters. Using this double approach we were able to propose a correlation between the evolution of surface chemical composition and surface wettability which are completely governed by the plasma treatment conditions. Chemical parameters as the elimination of the carbon contamination, the progressive surface oxidation, and the slight incorporation of nitrogen due to the air plasma interaction are well associated with the evolution of the wettability properties. So a complete engineering for the Ni–P surface preparation has been established. The sessile drop method can

  19. Wettability and XPS analyses of nickel-phosphorus surfaces after plasma treatment: An efficient approach for surface qualification in mechatronic processes

    Science.gov (United States)

    Vivet, L.; Joudrier, A.-L.; Bouttemy, M.; Vigneron, J.; Tan, K. L.; Morelle, J. M.; Etcheberry, A.; Chalumeau, L.

    2013-06-01

    Electroless nickel-high-phosphorus Ni-P plating is known for its physical properties. In case of electronic and mechatronic assembly processes achieved under ambient conditions the wettability of the Ni-P layer under ambient temperature and ambient air stays a point of surface quality investigation. This contribution will be devoted to the study of the surface properties of Ni-P films for which we performed air plasma treatment. We focus our attention on the evolution of the surface wettability, using the classical sessile drop technique. Interpreting the results with the OWRK model we extract the polar and disperse surface tension components from which we deduced typical evolution of the surface properties with the different treatment settings. By controlling the variations of the parameters of the plasma exposure we are able to change the responses of our Ni-P sample from total hydrophobic to total hydrophilic behaviours. All the intermediate states can be reached by adapting the treatment parameters. So it is demonstrated that the apparent Ni-P surface properties can be fully adapted and the surface setting can be well characterized by wettability measurements. To deep our knowledge of the surface modifications induced by plasma we performed parallel SEM and XPS analyses which provide informations on the structure and the chemical composition of the surface for each set of treatment parameters. Using this double approach we were able to propose a correlation between the evolution of surface chemical composition and surface wettability which are completely governed by the plasma treatment conditions. Chemical parameters as the elimination of the carbon contamination, the progressive surface oxidation, and the slight incorporation of nitrogen due to the air plasma interaction are well associated with the evolution of the wettability properties. So a complete engineering for the Ni-P surface preparation has been established. The sessile drop method can be

  20. Kinetic coefficients for quark-antiquark plasma

    International Nuclear Information System (INIS)

    Czyz, W.; Florkowski, W.

    1986-03-01

    The quark-antiquark plasma near equilibrium is studied. The results are based on the Heinz kinetic equations with the Boltzmann collision operator approximated by a relaxation term with the relaxation time, τ, treated as a small parameter. Linear in τ solutions of these equations are used to calculate the transport coefficients: the non-abelian version of Ohm's law, and the shear and volume viscosities. We introduce new chemical potentials which determine the color density matrix of quarks (antiquarks). Gradients of these potentials generate color currents. 12 refs. (author)