WorldWideScience

Sample records for plasma centrifuges

  1. APPLICATION ANALYSIS REPORT: RETECH PLASMA CENTRIFUGAL FURNACE

    Science.gov (United States)

    This document is an evaluation of the performance of the Retech, Inc. Plasma Centrifugal Furnace (PCF) and its applicability as a treatment for soils contaminated with organic and/or inorganic compounds. Both the technical and economic aspectsof the technology were examined. A...

  2. Stable isotope enrichment using a plasma centrifuge

    Science.gov (United States)

    Krishnan, Mahadevan; Bures, Brian; Madden, Robert

    2012-10-01

    A primary goal of the Department of Energy's Isotope Development and Production for Research and Applications Program (Isotope Program) within the Office of Nuclear Physics (NP) is to produce isotopes that are in short supply in the U.S. and of which there exists no or insufficient domestic commercial production capability. A vacuum arc plasma centrifuge is a rigid rotor column of metal plasma in which centrifugal forces re-distribute ions radially according to their mass/charge ratio. Early work demonstrated rotation at 2 million rpm and separation of various stable isotopes. The spinning plasma column had a Gaussian flux profile, peaked on the rigid rotor axis. This work adopts a more efficient approach, with the plasma created as a hollow column, wherein the flux is concentrated at larger radii where the centrifugal action is highest. By tailoring the vacuum arc discharge geometry, the rotation rate can also be increased to ˜10 million rpm. Data from Cu, Al and other metal plasmas will be presented and discussed in light of enriched stable isotopes needed for research and medicine.

  3. Wave-driven Countercurrent Plasma Centrifuge

    Energy Technology Data Exchange (ETDEWEB)

    A.J. Fetterman and N.J. Fisch

    2009-03-20

    A method for driving rotation and a countercurrent flow in a fully ionized plasma centrifuge is described. The rotation is produced by radiofrequency waves near the cyclotron resonance. The wave energy is transferred into potential energy in a manner similar to the α channeling effect. The countercurrent flow may also be driven by radiofrequency waves. By driving both the rotation and the flow pattern using waves instead of electrodes, physical and engineering issues may be avoided.

  4. Centrifugal acceleration of plasma in pulsar magnetosphere

    Indian Academy of Sciences (India)

    R T Gangadhara; V Krishna

    2003-12-01

    We present a relativistic model for the centrifugal acceleration of plasma bunches and the coherent radio emission in pulsar magnetosphere. We find that rotation broadens the width of leading component compared to the width of trailing component. We explain this difference in the component widths using the nested cone emission geometry. We estimate the effect of pulsar spin on the Stokes parameters, and find that the inclination between the rotation and magnetic axes can introduce an asymmetry in the circular polarization of the conal components. We analyse the single pulse polarization data of PSR B0329+54 at 606 MHz, and find that in its conal components, one sense of circular polarization dominates in the leading component while the other sense dominates in the trailing component. Our simulation shows that changing the sign of the impact parameter changes the sense of circular polarization as well as the swing of polarization angle.

  5. TECHNOLOGY EVALUATION REPORT: RETECH'S PLASMA CENTRIFUGAL FURNACE - VOLUME I

    Science.gov (United States)

    A demonstration of the Retech, Inc. Plasma Centrifugal Furnace (PCF) was conducted under the Superfund Innovative Technology Evaluation (SITE) Program at the Department of Energy's (DOE's) Component Development and Integration Facility in Butte, Montana. The furnace uses heat gen...

  6. DEMONSTRATION BULLETIN: THE PLASMA CENTRIFUGAL FURNACE RETECH, INC.

    Science.gov (United States)

    The plasma centrifugal furnace is a thermal technology which uses the heat generated from a plasma torch to decontaminate metal and organic contaminated waste. This is accomplished by melting metal-bearing solids and, in the process, thermally destroying organic contaminants. The...

  7. Low-molecular weight plasma proteome analysis using centrifugal ultrafiltration.

    Science.gov (United States)

    Greening, David W; Simpson, Richard J

    2011-01-01

    The low-molecular weight fraction (LMF) of the human plasma proteome is an invaluable source of biological information, especially in the context of identifying plasma-based biomarkers of disease. This protocol outlines a standardized procedure for the rapid/reproducible LMF profiling of human plasma samples using centrifugal ultrafiltration fractionation, followed by 1D-SDS-PAGE separation and nano-LC-MS/MS. Ultrafiltration is a convective process that uses anisotropic semipermeable membranes to separate macromolecular species on the basis of size. We have optimized centrifugal ultrafiltration for plasma fractionation with respect to buffer and solvent composition, centrifugal force, duration and temperature to facilitate >95% recovery, and enrichment of low-M (r) components from human plasma. Using this protocol, >260 unique peptides can be identified from a single plasma profiling experiment using 100 μL of plasma (Greening and Simpson, J Proteomics 73:637-648, 2010). The efficacy of this method is demonstrated by the identification, for the first time, of several plasma proteins (e.g., protein KIAA0649 (Q9Y4D3), rheumatoid factor D5, serine protease inhibitor A3, and transmembrane adapter protein PAG) previously not reported in extant high-confidence Human Proteome Organization Plasma Proteome Project datasets.

  8. Experiments on Plasma Injection into a Centrifugally Confined System

    Science.gov (United States)

    Messer, S.; Bomgardner, R.; Brockington, S.; Case, A.; Witherspoon, F. D.; Uzun-Kaymak, I.; Elton, R.; Young, W.; Teodorescu, C.; Morales, C. H.; Ellis, R. F.

    2009-11-01

    We describe the cross-field injection of plasma into a centrifugally-confined system. Two different types of plasma railgun have been installed on the Maryland Centrifugal Experiment (MCX) in an attempt to drive that plasma's rotation. The initial gun was a coaxial device designed to mitigate the blowby instability. The second one was a MiniRailgun with a rectangular bore oriented so that the MCX magnetic field augments the railgun's internal magnetic field. Tests at HyperV indicate this MiniRailgun reaches much higher densities than the original gun, although muzzle velocity is slightly reduced. We discuss the impact of these guns on MCX for various conditions. Initial results show that even for a 2 kG field, firing the MiniRailgun modifies oscillations of the MCX diamagnetic loops and can impact the core current and voltage. The gun also has a noticeable impact on MCX microwave emissions. These observations suggest plasma enters the MCX system. We also compare diagnostic data collected separately from MCX for these and other guns, focussing primarily on magnetic measurements.

  9. Centrifugal Separation and Equilibration Dynamics in an Electron-Antiproton Plasma

    Science.gov (United States)

    Andresen, G. B.; Ashkezari, M. D.; Baquero-Ruiz, M.; Bertsche, W.; Bowe, P. D.; Butler, E.; Cesar, C. L.; Chapman, S.; Charlton, M.; Deller, A.; Eriksson, S.; Fajans, J.; Friesen, T.; Fujiwara, M. C.; Gill, D. R.; Gutierrez, A.; Hangst, J. S.; Hardy, W. N.; Hayden, M. E.; Humphries, A. J.; Hydomako, R.; Jonsell, S.; Madsen, N.; Menary, S.; Nolan, P.; Olin, A.; Povilus, A.; Pusa, P.; Robicheaux, F.; Sarid, E.; Silveira, D. M.; So, C.; Storey, J. W.; Thompson, R. I.; van der Werf, D. P.; Wurtele, J. S.; Yamazaki, Y.

    2011-04-01

    Charges in cold, multiple-species, non-neutral plasmas separate radially by mass, forming centrifugally separated states. Here, we report the first detailed measurements of such states in an electron-antiproton plasma, and the first observations of the separation dynamics in any centrifugally separated system. While the observed equilibrium states are expected and in agreement with theory, the equilibration time is approximately constant over a wide range of parameters, a surprising and as yet unexplained result. Electron-antiproton plasmas play a crucial role in antihydrogen trapping experiments.

  10. Centrifugal separation and equilibration dynamics in an electron-antiproton plasma

    CERN Document Server

    Andresen, G B; Baquero-Ruiz, Marcelo; Bertsche, William; Bowe, Paul D; Butler, Eoin; Cesar, Claudio L; Chapman, Steven; Charlton, Michael; Deller, A; Eriksson, S; Fajans, Joel; Friesen, Tim; Fujiwara, Makoto C; Gill, David R; Gutierrez, A; Hangst, Jeffrey S; Hardy, Walter N; Hayden, Michael E; Humphries, Andrew J; Hydomako, Richard; Jonsell, Svante; Madsen, Niels; Menary, Scott; Nolan, Paul; Olin, Art; Povilus, Alexander; Pusa, Petteri; Robicheaux, Francis; Sarid, Eli; Silveira, Daniel M; So, Chukman; Storey, James W; Thompson, Robert I; van der Werf, Dirk P; Wurtele, Jonathan S; Yamazaki, Yasunori

    2011-01-01

    Charges in cold, multiple-species, non-neutral plasmas separate radially by mass, forming centrifugally-separated states. Here, we report the first detailed measurements of such states in an electron-antiproton plasma, and the first observations of the separation dynamics in any centrifugally-separated system. While the observed equilibrium states are expected and in agreement with theory, the equilibration time is approximately constant over a wide range of parameters, a surprising and as yet unexplained result. Electron-antiproton plasmas play a crucial role in antihydrogen trapping experiments.

  11. Centrifugation:an important pre-analytic procedure that influences plasma microRNA quantification during blood processing

    Institute of Scientific and Technical Information of China (English)

    Xiao-Hui Zheng; Cui Cui; Xin-Xi Zhou; Yi-Xin Zeng; Wei-Hua Jia

    2013-01-01

    Circulating microRNAs are robustly present in plasma or serum and have become a research focus as biomarkers for tumor diagnosis and prognosis. Centrifugation is a necessary procedure for obtaining high-quality blood supernatant. Herein, we investigated one-step and two-step centrifugations, two centrifugal methods routinely used in microRNA study, to explore their effects on plasma microRNA quantification. The microRNAs obtained from one-step and two-step centrifugations were quantified by microarray and TaqMan-based real-time quantitative polymerase chain reaction (Q-PCR). Dynamic light scattering was performed to explore the difference underlying the two centrifugal methods. The results from the microarray containing 1,347 microRNAs showed that the signal detection rate was greatly decreased in the plasma sample prepared by two-step centrifugation. More importantly, the microRNAs missing in this plasma sample could be recovered and detected in the precipitate generated from the second centrifugation. Consistent with the results from microarray, a marked decrease of three representative microRNAs in two-step centrifugal plasma was validated by Q-PCR. According to the size distribution of all nanoparticles in plasma, there were fewer nanoparticles with size >1,000 nm in two-step centrifugal plasma. Our experiments directly demonstrated that different centrifugation methods produced distinct quantities of plasma microRNAs. Thus, exosomes or protein complexes containing microRNAs may be involved in large nanoparticle formation and may be precipitated after two-step centrifugation. Our results remind us that sample processing methods should be first considered in conducting research.

  12. Plasma centrifuge with vacuum arc discharge applied to the separation of stable isotopes

    Science.gov (United States)

    Delbosco, Edson

    1989-09-01

    The results of a vacuum-arc plasma centrifuge experiment are described. A plasma centrifuge is an apparatus where a plasma column is produced due to the interaction of an electric current with an externally applied magnetic field, vector J x vector B. Among the applications of a rotating plasma, this work deals particularly with its utilization in an isotope enrichment device. The main characteristics of the plasma produced in this experiment are presented, with special attention to the plasma column rotation and the isotope enrichment. The analysis of the results is performed using a fluid model for a completely ionized rigid body rotating plasma column in steady state equilibrium. The main results are: (1) rotation frequency of the plasma column in the range 2 x (exp 4) to 3 x 10 (exp 5) rad/s; (2) enrichment of 10 to 30 pct for the magnesium isotopes, and 290 to 490 pct for the carbon-13 isotope; (3) rigid body rotation of the plasma column only for radii smaller than the characteristic radius of the plasma column, r(sub e); (4) linear dependence of the rotation frequency upon the magnetic field strength only for r is less than r(sub e); (5) existence of an optimum value of the magnetic field for maximum enrichment; and (6) dependence of the rotation frequency upon the inverse of the atomic mass.

  13. Accuracy assessment on the analysis of unbound drug in plasma by comparing traditional centrifugal ultrafiltration with hollow fiber centrifugal ultrafiltration and application in pharmacokinetic study.

    Science.gov (United States)

    Zhang, Lin; Zhang, Zhi-Qing; Dong, Wei-Chong; Jing, Shao-Jun; Zhang, Jin-Feng; Jiang, Ye

    2013-11-29

    In present study, accuracy assessment on the analysis of unbound drug in plasma was made by comparing traditional centrifugal ultrafiltration (CF-UF) with hollow fiber centrifugal ultrafiltration (HFCF-UF). We used metformin (MET) as a model drug and studied the influence of centrifugal time, plasma condition and freeze-thaw circle times on the ultrafiltrate volume and related effect on the measurement of MET. Our results demonstrated that ultrafiltrate volume was a crucial factor which influenced measurement accuracy of unbound drug in plasma. For traditional CF-UF, the ultrafiltrate volume cannot be well-controlled due to a series of factors. Compared with traditional CF-UF, the ultrafiltrate volume by HFCF-UF can be easily controlled by the inner capacity of the U-shaped hollow fiber inserted into the sample under enough centrifugal force and centrifugal time, which contributes to a more accurate measurement. Moreover, the developed HFCF-UF method achieved a successful application in real plasma samples and exhibited several advantages including high precision, extremely low detection limit and perfect recovery. The HFCF-UF method offers the advantage of highly satisfactory performance in addition to being simple and fast in pretreatment, with these characteristics being consistent with the practicability requirements in current scientific research.

  14. Toxic waste treatment with sliding centrifugal plasma reactor; Tratamiento de residuos toxicos con reactores de plasma centrifugo deslizante (PCD)

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, J.; Pacheco, M.; Valdivia, R.; Ramos, F.; Duran, M.; Hidalgo, M.; Cruz, A.; Martinez, J. C.; Martinez, R.; De la Cruz, S.; Flores, T.; Vidal, E.; Escobar, S. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Garduno, M.; Garcia, M.; Portillo, J.; Torres, C.; Estrada, N.; Velazquez, S.; Vasquez, C. [Instituto Tecnologico de Toluca, Av. Instituto Tecnologico s/n, Ex-Rancho la Virgen, Metepec 52140, Estado de Mexico (Mexico)

    2008-07-01

    The aim is to develop technology for hazardous waste treatment, including the building and putting into operation of a prototype based on a sliding centrifugal plasma technology to demonstrate its ability to degradation taking in account the existing environmental standards. (Author)

  15. Evaluation of a reduced centrifugation time and higher centrifugal force on various general chemistry and immunochemistry analytes in plasma and serum.

    Science.gov (United States)

    Møller, Mette F; Søndergaard, Tove R; Kristensen, Helle T; Münster, Anna-Marie B

    2017-09-01

    Background Centrifugation of blood samples is an essential preanalytical step in the clinical biochemistry laboratory. Centrifugation settings are often altered to optimize sample flow and turnaround time. Few studies have addressed the effect of altering centrifugation settings on analytical quality, and almost all studies have been done using collection tubes with gel separator. Methods In this study, we compared a centrifugation time of 5 min at 3000 ×  g to a standard protocol of 10 min at 2200 ×  g. Nine selected general chemistry and immunochemistry analytes and interference indices were studied in lithium heparin plasma tubes and serum tubes without gel separator. Results were evaluated using mean bias, difference plots and coefficient of variation, compared with maximum allowable bias and coefficient of variation used in laboratory routine quality control. Results For all analytes except lactate dehydrogenase, the results were within the predefined acceptance criteria, indicating that the analytical quality was not compromised. Lactate dehydrogenase showed higher values after centrifugation for 5 min at 3000 ×  g, mean bias was 6.3 ± 2.2% and the coefficient of variation was 5%. Conclusions We found that a centrifugation protocol of 5 min at 3000 ×  g can be used for the general chemistry and immunochemistry analytes studied, with the possible exception of lactate dehydrogenase, which requires further assessment.

  16. The concept of a plasma centrifuge with a high frequency rotating magnetic field and axial circulation

    Science.gov (United States)

    Borisevich, V. D.; Potanin, E. P.

    2017-07-01

    The possibility of using a rotating magnetic field (RMF) in a plasma centrifuge (PC), with axial circulation to multiply the radial separation effect in an axial direction, is considered. For the first time, a traveling magnetic field (TMF) is proposed to drive an axial circulation flow in a PC. The longitudinal separation effect is calculated for a notional model, using specified operational parameters and the properties of a plasma, comprising an isotopic mixture of 20Ne-22Ne and generated by a high frequency discharge. The optimal intensity of a circulation flow, in which the longitudinal separation effect reaches its maximum value, is studied. The optimal parameters of the RMF and TMF for effective separation, as well as the centrifuge performance, are calculated.

  17. Prediction and optimization of the recovery rate in centrifugal separation of platelet-rich plasma (PRP)

    Science.gov (United States)

    Piao, Linfeng; Park, Hyungmin; Jo, Chris

    2016-11-01

    We present a theoretical model of the recovery rate of platelet and white blood cell in the process of centrifugal separation of platelet-rich plasma (PRP). For the practically used conditions in the field, the separation process is modeled as a one-dimensional particle sedimentation; a quasi-linear partial differential equation is derived based on the kinematic-wave theory. This is solved to determine the interface positions between supernatant-suspension and suspension-sediment, used to estimate the recovery rate of the plasma. While correcting the Brown's hypothesis (1989) claiming that the platelet recovery is linearly proportional to that of plasma, we propose a new correlation model for prediction of the platelet recovery, which is a function of the volume of whole blood, centrifugal acceleration and time. For a range of practical parameters, such as hematocrit, volume of whole blood and centrifugation (time and acceleration), the predicted recovery rate shows a good agreement with available clinical data. We propose that this model is further used to optimize the preparation method of PRP that satisfies the customized case. Supported by a Grant (MPSS-CG-2016-02) through the Disaster and Safety Management Institute funded by Ministry of Public Safety and Security of Korean government.

  18. A simple sample preparation method for measuring amoxicillin in human plasma by hollow fiber centrifugal ultrafiltration.

    Science.gov (United States)

    Dong, Wei-Chong; Hou, Zi-Li; Jiang, Xin-Hui; Jiang, Ye

    2013-02-01

    A simple sample preparation method has been developed for the determination of amoxicillin in human plasma by hollow fiber centrifugal ultrafiltration (HF-CF-UF). A 400-μL plasma sample was placed directly into the HF-CF-UF device, which consisited of a slim glass tube and a U-shaped hollow fiber. After centrifugation at 1.25 × 10(3) g for 10 min, the filtrate was withdrawn from the hollow fiber and 20 µL was directly injected into the high-performance liquid chromatography (HPLC) for analysis. The calibration curve was linear over the range of 0.1-20 µg/mL (r = 0.9996) and the limit of detection was as low as 0.025 µg/mL. The average recovery and absolute recovery were 99.9% and 84.5%, respectively. Both the intra-day and inter-day precisions (relative standard deviation) were less than 3.1% for three concentrations (0.25, 2.5 and 10 µg/mL). The sample preparation process was simplified. Only after a single centrifugal ultrafiltration can the filtrate be injected directly into HPLC. The present method is simple, sensitive and accurate. It could be effective for the analysis of biological samples with high protein contents, especially for the biopharmaceutical analysis of drugs that use traditional isolation techniques for sample preparation such as the protein precipitation method.

  19. Plasma Skimming in a Spiral Groove Bearing of a Centrifugal Blood Pump.

    Science.gov (United States)

    Murashige, Tomotaka; Sakota, Daisuke; Kosaka, Ryo; Nishida, Masahiro; Kawaguchi, Yasuo; Yamane, Takashi; Maruyama, Osamu

    2016-09-01

    Plasma skimming is a phenomenon in which discharge hematocrit is lower than feed hematocrit in microvessels. Plasma skimming has been investigated at a bearing gap in a spiral groove bearing (SGB), as this has the potential to prevent hemolysis in the SGB of a blood pump. However, it is not clear whether plasma skimming occurs in a blood pump with the SGB, because the hematocrit has not been obtained. The purpose of this study is to verify plasma skimming in an SGB of a centrifugal blood pump by developing a hematocrit measurement method in an SGB. Erythrocyte observation using a high-speed microscope and a bearing gap measurement using a laser confocal displacement meter was performed five times. In these tests, bovine blood as a working fluid was diluted with autologous plasma to adjust the hematocrit to 1.0%. A resistor was adjusted to achieve a pressure head of 100 mm Hg and a flow rate of 5.0 L/min at a rotational speed of 2800 rpm. Hematocrit on the ridge region in the SGB was measured using an image analysis based on motion image of erythrocytes, mean corpuscular volume, the measured bearing gap, and a cross-sectional area of erythrocyte. Mean hematocrit on the ridge region in the SGB was linearly reduced from 0.97 to 0.07% with the decreasing mean bearing gap from 38 to 21 μm when the rotational speed was changed from 2250 to 3000 rpm. A maximum plasma skimming efficiency of 93% was obtained with a gap of 21 μm. In conclusion, we succeeded in measuring the hematocrit on the ridge region in the SGB of the blood pump. Hematocrit decreased on the ridge region in the SGB and plasma skimming occurred with a bearing gap of less than 30 μm in the hydrodynamically levitated centrifugal blood pump.

  20. Pre-storage centrifugation conditions have significant impact on measured microRNA levels in biobanked EDTA plasma samples

    DEFF Research Database (Denmark)

    Binderup, Helle Glud; Houlind, Kim; Madsen, Jonna Skov;

    2016-01-01

    was significantly higher in the re-centrifuged biobanked plasma compared to PPP, even when the platelet count was reduced to 0-1×109/L. Conclusion: We found, that pre-storage centrifugation conditions have a significant impact on the measured EDTA plasma level of miRNAs known to be present in platelets. Even......Background: In the past few years, an increasing number of studies have reported the potential use of microRNAs (miRNA) as circulating biomarkers for diagnosis or prognosis of a wide variety of diseases. There is, however, a lack of reproducibility between studies. Due to the high miRNA content...

  1. Cell adhesion to plasma electrolytic oxidation (PEO) titania coatings, assessed using a centrifuging technique.

    Science.gov (United States)

    Robinson, H J; Markaki, A E; Collier, C A; Clyne, T W

    2011-11-01

    The adhesion of bovine chondrocytes and human osteoblasts to three titania-based coatings, formed by plasma electrolytic oxidation (PEO), was compared to that on uncoated Ti-6Al-4V substrates, and some comparisons were also made with plasma sprayed hydroxyapatite (HA) coatings. This was done using a centrifuge, with accelerations of up to 160,000 g, so as to induce buoyancy forces that created normal or shear stresses at the interface. It is shown that, on all surfaces, it was easier to remove cells under normal loading than under shear loading. Cell adhesion to the PEO coatings was stronger than that on Ti-6Al-4V and similar to that on HA. Cell proliferation rates were relatively high on one of the PEO coatings, which was virtually free of aluminium, but low on the other two, which contained significant levels of aluminium. It is concluded that the Al-free PEO coating offers promise for application to prosthetic implants.

  2. Analysis of efficiency of the double- centrifugation protocol to prepare platelet rich plasma (PRP – an experimental study in rabbits

    Directory of Open Access Journals (Sweden)

    Michel Reis MESSORA

    2009-09-01

    Full Text Available Introduction and objective:The purpose of this study was to evaluatethe concentrations of platelets obtained from platelet rich plasma (PRP prepared according to the double-centrifugation protocol. Material and methods: Eight adult male rabbits (White New Zealand weighing 2.8 to 4 kg were used.After general anesthesia, 10 ml of blood were drawn from each animal via cardiac puncture. Each blood sample was centrifuged according to the protocol of Sonnleitner et al.(2000.The peripheral blood (total from each animal and the PRP samples platelets were counted manually. Data were submitted to statistical analysis.The normality of the data was confirmed and the Student’s t test was applied (p < 0.05.Results: PRP samples presented an average platele count significantly higher than that of peripheral blood.Conclusion Within the limits of this study, it was concluded that the double centrifugation protocol was adequate to prepare PRP .

  3. Isotopic separation by centrifugation. Rotating plasma; Separacion Isotopic por Centrifugacion Plasma Rotante

    Energy Technology Data Exchange (ETDEWEB)

    Perello, M.; Vigon, M. A.

    1972-07-01

    The motion of a gas simultaneously submitted to an electric discharge and magnetic field has been studied in order to analyze the possibility of producing isotopes separation by rotation of a plasma. Some experimental results obtained under different discharge conditions are also given. Differences of pressure up to 15 mm oil between both electrodes has been attained. No definite conclusion on separation factors could be reached because of the low reproducibility of results, probably due to the short duration of the discharge with a new chamber designed to support stronger thermal shocks more reliable data can be expected. (Author) 16 refs.

  4. Boundary-value problem for a counterrotating electrical discharge in an axial magnetic field. [plasma centrifuge for isotope separation

    Science.gov (United States)

    Hong, S. H.; Wilhelm, H. E.

    1978-01-01

    An electrical discharge between two ring electrodes embedded in the mantle of a cylindrical chamber is considered, in which the plasma in the anode and cathode regions rotates in opposite directions under the influence of an external axial magnetic field. The associated boundary-value problem for the coupled partial differential equations describing the azimuthal velocity and radial current-density fields is solved in closed form. The velocity, current density, induced magnetic induction, and electric fields are presented for typical Hartmann numbers, magnetic Reynolds numbers, and geometry parameters. The discharge is shown to produce anodic and cathodic plasma sections rotating at speeds of the order 1,000,000 cm/sec for conventional magnetic field intensities. Possible application of the magnetoactive discharge as a plasma centrifuge for isotope separation is discussed.

  5. Studies on new process procedures in plasma fractionation and industrial scale. III. Removal of precipitates by filtration through a horizontal leaf filter with centrifugal cleaning (Funda filter) as an alternative to tubular-bowl centrifuges.

    Science.gov (United States)

    Friedli, H; Mauerhofer, M; Faes, A; Kistler, P

    1976-10-01

    The possibilities for replacing the time-consuming and labor-intensive centrifugation step in the plasma fractionation process with a filtration technique using filter aids were explored using a Funda filter (pat. Dr. Ing. Hans Müller). The filtration technique proved effective in the separation of the impure plasma fractions. On the other hand, its use in the separation of pure albumin and gamma-globulin fractions appears doubtful.

  6. CENTRIFUGE APPARATUS

    Science.gov (United States)

    Skarstrom, C.; Urey, H.C.; Cohen, K.

    1960-08-01

    A high-speed centrifuge for the separation of gaseous isotopes is designed comprising a centrifugal pump mounted on the outlet of a centrifuge bowl and arranged to pump the heavy and light fractions out of the centrifuge bowl in two separate streams.

  7. Pretreatment of plasma samples by a novel hollow fiber centrifugal ultrafiltrate device for the determination of cefaclor concentrations in human plasma.

    Science.gov (United States)

    Li, Jun-Mei; Li, Cen; Jiang, Ye; Ren, Shu-Meng

    2010-10-29

    A simple sample preparation method was developed by using a centrifugal ultrafiltration (CF-UF) device with hollow fiber (HF) for the determination of cefaclor in plasma by HPLC. Samples were placed into a homemade device, which was consisted of a glass tube and a U-shaped hollow fiber. The filtrate was withdrawn from the hollow fiber into a syringe after centrifugation and 20 μL was directly injected into the HPLC for analysis. The HPLC method had a linear calibration curve in the concentration range of 6.00×10(-2)-30.7 μg mL(-1)(r=0.9996). The limit of detection (LOD) and limit of quantitation (LOQ) were 0.02 and 0.06 μg mL(-1), respectively. The intra and inter-day precisions (RSD) were 1.7%, 1.2%, 1.0% and 3.6%, 2.5%, 1.9%, respectively, for three concentrations. Assay accuracy was higher than 99.2% and the absolute recovery was 86.8-92.5%. It is feasible to use this novel and low cost device for sample pretreatment for the analysis of cefaclor in plasma.

  8. Severe Hemolysis in a Patient With Erythrocytosis During Coupled Plasma Filtration Adsorption Therapy Was Prevented by Changing From Membrane-Based Technique to a Centrifuge-Based One.

    Science.gov (United States)

    Fan, Rong; Wu, Buyun; Kong, Ling; Gong, Dehua

    2016-01-01

    Coupled plasma filtration adsorption (CPFA) usually adopts membrane to separate plasma from blood. Here, we reported a case with erythrocytosis experienced severe hemolysis and membrane rupture during CPFA, which was avoided by changing from membrane-based technique to a centrifuge-based one. A 66-year-old man was to receive CPFA for severe hyperbilirubinemia (total bilirubin 922 μmol/L, direct bilirubin 638 μmol/L) caused by obstruction of biliary tract. He had erythrocytosis (hemoglobin 230 g/L, hematocrit 0.634) for years because of untreated tetralogy of Fallot. Severe hemolysis and membrane rupture occurred immediately after blood entering into the plasma separator even at a low flow rate (50 mL/min) and persisted after changing a new separator. Finally, centrifugal plasma separation technique was used for CPFA in this patient, and no hemolysis occurred. After 3 sessions of CPFA, total bilirubin level decreased to 199 μmol/L with an average decline by 35% per session. Thereafter, the patient received endoscopic biliary stent implantation, and total bilirubin level returned to nearly normal. Therefore, centrifugal-based plasma separation can also be used in CPFA and may be superior to a membrane-based one in patients with hyperviscosity.

  9. Maryland Centrifugal Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Hassam, Adil; Ellis, Richard F

    2016-12-22

    The Maryland Centrifugal Experiment (MCX) Project has investigated the concepts of centrifugal plasma confinement and stabilization of instabilities by velocity shear. The basic requirement is supersonic plasma rotation about a shaped, open magnetic field. Overall, the MCX Project attained three primary goals that were set out at the start of the project. First, supersonic rotation at Mach number upto 2.5 was obtained. Second, turbulence from flute interchange modes was found considerably reduced from conventional. Third, plasma pressure was contained along the field, as evidenced by density drops of x10 from the center to the mirror throats.

  10. Structural and photoluminescence properties of silicon nanowires extracted by means of a centrifugation process from plasma torch synthesized silicon nanopowder

    Science.gov (United States)

    Le Borgne, Vincent; Agati, Marta; Boninelli, Simona; Castrucci, Paola; De Crescenzi, Maurizio; Dolbec, Richard; El Khakani, My Ali

    2017-07-01

    We report on a method for the extraction of silicon nanowires (SiNWs) from the by-product of a plasma torch based spheroidization process of silicon. This by-product is a nanopowder which consists of a mixture of SiNWs and silicon particles. By optimizing a centrifugation based process, we were able to extract substantial amounts of highly pure Si nanomaterials (mainly SiNWs and Si nanospheres (SiNSs)). While the purified SiNWs were found to have typical outer diameters in the 10-15 nm range and lengths of up to several μm, the SiNSs have external diameters in the 10-100 nm range. Interestingly, the SiNWs are found to have a thinner Si core (2-5 nm diam.) and an outer silicon oxide shell (with a typical thickness of ˜5-10 nm). High resolution transmission electron microscopy (HRTEM) observations revealed that many SiNWs have a continuous cylindrical core, whereas others feature a discontinuous core consisting of a chain of Si nanocrystals forming a sort of ‘chaplet-like’ structures. These plasma-torch-produced SiNWs are highly pure with no trace of any metal catalyst, suggesting that they mostly form through SiO-catalyzed growth scheme rather than from metal-catalyzed path. The extracted Si nanostructures are shown to exhibit a strong photoluminescence (PL) which is found to blue-shift from 950 to 680 nm as the core size of the Si nanostructures decreases from ˜5 to ˜3 nm. This near IR-visible PL is shown to originate from quantum confinement (QC) in Si nanostructures. Consistently, the sizes of the Si nanocrystals directly determined from HRTEM images corroborate well with those expected by QC theory.

  11. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  12. CENTRIFUGAL SEPARATORS

    Science.gov (United States)

    Skarstrom, C.

    1959-03-10

    A centrifugal separator is described for separating gaseous mixtures where the temperature gradients both longitudinally and radially of the centrifuge may be controlled effectively to produce a maximum separation of the process gases flowing through. Tbe invention provides for the balancing of increases and decreases in temperature in various zones of the centrifuge chamber as the result of compression and expansions respectively, of process gases and may be employed effectively both to neutralize harmful temperature gradients and to utilize beneficial temperaturc gradients within the centrifuge.

  13. Pretreatment of plasma samples by a novel hollow fiber centrifugal ultrafiltration technique for the determination of plasma protein binding of three coumarins using acetone as protein binding releasing agent.

    Science.gov (United States)

    Li, Junmei; Shi, Qingwen; Jiang, Ye; Liu, Yan

    2015-09-15

    A novel and practical sample pretreatment method based on hollow fiber centrifugal ultrafiltration (HFCF-UF) was developed to determine plasma protein binding by using HPLC. The samples for analyzing unbound and total concentrations could be prepared in parallel simultaneously by the same device. It only required centrifugation for a short time and the filtrate could be injected directly for HPLC analysis without further treatment. Coumarins were selected as the model drugs. Acetone was chosen as the releasing agent to free the binding drug from the drug-protein complex for the total drug concentration determination. Non-specific bindings (NSBs) between the analytes and hollow fiber membrane materials were investigated. The type and volume of protein binding releaser were optimized. Additionally, centrifugal speed and centrifugal time were considered. Under the optimized conditions, the absolute recovery rates of the unbound and total concentrations were in the range of 97.5-100.9% for the three analytes. The limits of detection were in the range of 0.0135-0.0667μgmL(-1). In vitro plasma protein binding of the three coumarins was determined at three concentrations using the validated method and the relative standard deviations (RSDs) were less than 3.4%. Compared with traditional method, the HFCF-UF method is simple to run, no specialized equipment requirement and is a more accurate plasma pretreatment procedure with almost excellent drug-protein binding equilibrium. Therefore, this method can be applied to determine the plasma protein binding in clinical practice. It also provides a reliable alternative for accurate monitoring of unbound or total drug concentration in therapeutic drug monitoring (TDM).

  14. Numerical Study of Velocity Shear Stabilization of 3D and Theoretical Considerations for Centrifugally Confined Plasmas and Other Interchange-Limited Fusion Concepts

    Energy Technology Data Exchange (ETDEWEB)

    Hassam, Adil [Univ. of Maryland, College Park, MD (United States)

    2015-09-21

    We studied the feasibility of resonantly driving GAMs in tokamaks. A numerical simulation was carried out and showed the essential features and limitations. It was shown further that GAMs can damp by phase-mixing, from temperature gradients, or nonlinear detuning, thus broadening the resonance. Experimental implications of this were quantified. Theoretical support was provided for the Maryland Centrifugal Experiment, funded in a separate grant by DOE. Plasma diamagnetism from supersonic rotation was established. A theoretical model was built to match the data. Additional support to the experiment in terms of numerical simulation of the interchange turbulence was provided. Spectra from residual turbulence on account of velocity shear suppression were obtained and compared favorably to experiment. A new drift wave, driven solely by the thermal force, was identified.

  15. Centrifugal pyrocontactor

    Science.gov (United States)

    Chow, Lorac S.; Leonard, Ralph A.

    1993-01-01

    A method for mixing and separating immiscible liquid salts and liquid metals in a centrifugal contractor. The method includes introducing the liquids into an annular mixing zone and intensely mixing the liquids using vertical vanes attached to a rotor cooperating with vertical baffles, a horizontal baffle, and bottom vanes attached to the contactor housing. The liquids enter the contactor in the range of 700-800 degrees Celsius. The liquids are separated in the rotor into a dense phase and a light phase which are discharged from the contactor.

  16. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  17. A Rapid Centrifugation-Assisted Solid-Phase Extraction and Liquid Chromatography Method for Determination of Loureirin A and Loureirin B of Dragon's Blood Capsules in Rat Plasma and Urine After Oral Administration.

    Science.gov (United States)

    Chen, Xiaoshuang; Li, Gaofeng; Ma, Shangfang; Hu, Xujia

    2015-07-01

    A simple, sensitive and rapid centrifugation-assisted solid-phase extraction (SPE) with high-performance liquid chromatography (SPE-HPLC) method was developed for simultaneous determination of the metabolites loureirin A and loureirin B from Dragon's blood in rat plasma and urine. The development of the extraction procedure included optimization of some important extraction phases. After evaluation, the metabolites of Dragon's blood were extracted by centrifugation-assisted SPE and separated by using HPLC. This method showed good linearity (r(2) > 0.99), and in the rat plasma and urine, the recoveries were 93.1 and 95.7% for loureirin A and were 90.1 and 94.2% for loureirin B. The relative standard deviation (RSD) values of intraday and interday precision in rat plasma and urine for loureirin A were <3.84 and 2.01%, respectively. The RSD values of the intraday and interday precision in rat plasma and urine for loureirin B were below 4.25 and 5.83%, respectively. Thus, the established method is suitable for metabolism studies of loureirin A and loureirin B in rat plasma and urine. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Centrifuge modeling of monopiles

    DEFF Research Database (Denmark)

    Klinkvort, Rasmus Tofte

    2010-01-01

    To gain a larger knowledge of the monopile foundation concept, centrifuge modeling is used by the geotechnical group at DTU. The centrifuge operated at DTU is a beam centrifuge and was built in 1976. In the recent years it has been upgraded with onboard data acquisition and control systems. The c...... from centrifuge tests performed on large diameter piles installed in dry sand.......To gain a larger knowledge of the monopile foundation concept, centrifuge modeling is used by the geotechnical group at DTU. The centrifuge operated at DTU is a beam centrifuge and was built in 1976. In the recent years it has been upgraded with onboard data acquisition and control systems....... The capabilities of the centrifuge at DTU makes it possible to obtain a scale factor of 85 in experiments which equals a soil volume in prototype scale of a diameter of 40 meters and a depth of 40 meters. This paper describes centrifuge modeling theory, the centrifuge setup at DTU and as an example show results...

  19. METHOD OF CENTRIFUGE OPERATION

    Science.gov (United States)

    Cohen, K.

    1960-05-10

    A method of isotope separation is described in which two streams are flowed axially of, and countercurrently through, a cylindrical centrifuge bowl. Under the influence of a centrifugal field, the light fraction is concentrated in a stream flowing through the central portion of the bowl, whereas the heavy fraction is concentrated in a stream at the periphery thereof.

  20. Centrifugal pump handbook

    CERN Document Server

    Pumps, Sulzer

    2010-01-01

    This long-awaited new edition is the complete reference for engineers and designers working on pump design and development or using centrifugal pumps in the field. This authoritative guide has been developed with access to the technical expertise of the leading centrifugal pump developer, Sulzer Pumps. In addition to providing the most comprehensive centrifugal pump theory and design reference with detailed material on cavitation, erosion, selection of materials, rotor vibration behavior and forces acting on pumps, the handbook also covers key pumping applications topics and operational

  1. 离心力、时间对富血小板血浆中生长因子浓度的影响%The Influence of Centrifugal Force and Time on Growth Factor Concentration in Platelet Rich Plasma

    Institute of Scientific and Technical Information of China (English)

    林颢; 孙杰聪; 李广盛; 郑锦畅; 魏波

    2014-01-01

    Objective To detect the concentration of TGF-β in platelet rich plasma (PRP) that was prepared under dif erent centrifugal force and time, and make a related analysis. Aiming to investigate the most appropriate centrifugal force and time for preparing PRP. Methods Collect 200ml peripheral blood from volunteers, anticoagulated it with EDTA at stored at 4℃ for later use. Ful-automatic blood analyzer was used for the platelet counting, isolated the PRP by quadratic centrifugation (with dif erent centrifugal force and time),then counted the platelet again with full-automatic blood analyzer. The concentration of TGF-β in PRP was detected by ELISA detection. Results The concentration of platelet in peripheral blood was 146.36í109/L, and in PRP was (757.27±55.07)í109L.The concentration of TGF-β in PRP was (737.68±62.7)ng/ml.We found that the concentration of TGF-β in PRP that isolated under 900g,10min combined with 700g,10min was the highest (881.5í10)9/L,824.2 ng/ml).Conclusion The quality of PRP the preparation is closely related to the centrifugal force and time. The appropriate centrifugation and time is more likely to a get high concentration of PRP that rich in growth factors.%目的探索应用不同的离心速度来制备的富血小板血浆(platelet rich plasma,PRP)中TGF生长因子的含量,并做相关分析,尝试阐明制备PRP最合适的离心次数及速度。方法采集自愿者外周血200ml,应用EDTA抗凝,4º保存以备用。应用全自动血液分析仪进行血小板计数,采用二次离心法(不同的离心速度、时间)分离出PRP,再次用全自动血液分析仪进行血小板计数,然后用ELISA法检测所得的PRP中的TGF-β的浓度。结果外周血中的血小板浓度为146.36×109L,PRP的血小板浓度为(757.27±55.07)×109L。 PRP中的TGF-β浓度为(737.68±62.7)ng/ml。其中以900g,10min,700g,10min,这个离心速度与时间组合所得的PRP血小板

  2. Centrifugal acceleration in the magnetotail lobes

    Directory of Open Access Journals (Sweden)

    H. Nilsson

    2010-02-01

    Full Text Available Combined Cluster EFW and EDI measurements have shown that cold ion outflow in the magnetospheric lobes dominates the hydrogen ion outflow from the Earth's atmosphere. The ions have too low kinetic energy to be measurable with particle instruments, at least for the typical spacecraft potential of a sunlit spacecraft in the tenuous lobe plasmas outside a few RE. The measurement technique yields both density and bulk velocity, which can be combined with magnetic field measurements to estimate the centrifugal acceleration experienced by these particles. We present a quantitative estimate of the centrifugal acceleration, and the velocity change with distance which we would expect due to centrifugal acceleration. It is found that the centrifugal acceleration is on average outward with an average value of about of 5 m s−2. This is small, but acting during long transport times and over long distances the cumulative effect is significant, while still consistent with the relatively low velocities estimated using the combination of EFW and EDI data. The centrifugal acceleration should accelerate any oxygen ions in the lobes to energies observable by particle spectrometers. The data set also put constraints on the effectiveness of any other acceleration mechanisms acting in the lobes, where the total velocity increase between 5 and 19 RE geocentric distance is less than 5 km s−1.

  3. Perceived radial translation during centrifugation

    NARCIS (Netherlands)

    Bos, J.E.; Correia Grácio, B.J.

    2015-01-01

    BACKGROUND: Linear acceleration generally gives rise to translation perception. Centripetal acceleration during centrifugation, however, has never been reported giving rise to a radial, inward translation perception. OBJECTIVE: To study whether centrifugation can induce a radial translation percepti

  4. Centrifugal atomisation of alloys

    Energy Technology Data Exchange (ETDEWEB)

    Li Huiping [School of Mechanical and Materials Engineering, Univ. of Surrey, Guilford (United Kingdom); Dept. of Inorganic Materials, East China Univ. of Science and Technology, Shanghai, SH (China); Tsakiropoulos, P. [School of Mechanical and Materials Engineering, Univ. of Surrey, Guilford (United Kingdom); Johnson, T. [Tetronics Ltd., Faringdon, Oxfordshire (United Kingdom)

    2001-07-01

    Centrifugal atomisation using a rotating disk is described and compared to REP and PREP. Results of calculations of models describing the interaction of a melt with a rotating disk, the formation of thin film on the disk and the break up of the thin film and its atomisation at the edge of the disk are compared with experimental results. (orig.)

  5. Central centrifugal cicatricial alopecia

    Directory of Open Access Journals (Sweden)

    Collin Blattner

    2013-01-01

    Full Text Available Central centrifugal cicatricial alopecia is a common cause of progressive permanent apical alopecia. This unique form of alopecia includes entities previously know as "hot comb alopecia," "follicular degeneration syndrome," "pseudopelade" in African Americans and "central elliptical pseudopelade" in Caucasians. The etiology appears to be multifactorial and the condition occurs in all races.

  6. Pumps, Centrifugal and Reciprocating

    Science.gov (United States)

    2011-04-27

    guidance for preparing test plans and conducting test programs to evaluate the effectiveness and suitability for military use of centrifugal and...This page is intentionally blank.)   US ARMY DEVELOPMENTAL TEST COMMAND TEST...Satisfy the needs of MIL-STD-4612. High-Altitude Electromagnetic Pulse ( HEMP ) Test Facility Satisfy the needs of MIL-STD-461. Rail Impact Test

  7. Rapid detection of simulated bacteremia by centrifugation and filtration.

    OpenAIRE

    Herlich, M B; Schell, R F; Francisco, M.; Le Frock, J L

    1982-01-01

    A centrifugation-filtration procedure was developed to expedite the recovery of microorganisms from blood. Fresh whole human blood was inoculated with various aerobic and facultatively anaerobic microorganisms (3 to 18 per ml). The seeded blood was carefully overlaid on a Ficoll-Hypaque gradient (density, 1.114 g/ml) and centrifuged (400 x g) for 45 min at ambient temperature. The entire gradient (plasma, leukocytes, and Ficoll-Hypaque) was removed and filtered through a 0.22-micrometer membr...

  8. Centrifugal unbalance detection system

    Science.gov (United States)

    Cordaro, Joseph V.; Reeves, George; Mets, Michael

    2002-01-01

    A system consisting of an accelerometer sensor attached to a centrifuge enclosure for sensing vibrations and outputting a signal in the form of a sine wave with an amplitude and frequency that is passed through a pre-amp to convert it to a voltage signal, a low pass filter for removing extraneous noise, an A/D converter and a processor and algorithm for operating on the signal, whereby the algorithm interprets the amplitude and frequency associated with the signal and once an amplitude threshold has been exceeded the algorithm begins to count cycles during a predetermined time period and if a given number of complete cycles exceeds the frequency threshold during the predetermined time period, the system shuts down the centrifuge.

  9. Centrifugally decoupling touchdown bearings

    Science.gov (United States)

    Post, Richard F

    2014-06-24

    Centrifugally decoupling mechanical bearing systems provide thin tensioned metallic ribbons contained in a support structure. This assembly rotates around a stationary shaft being centered at low speeds by the action of the metal ribbons. Tension springs are connected on one end to the ribbons and on the other end to the support structure. The ribbons pass through slots in the inner ring of the support structure. The spring preloading thus insures contact (or near-contact) between the ribbons and the shaft at rotation speeds below the transition speed. Above this speed, however, the centrifugal force on the ribbons produces a tensile force on them that exceeds the spring tensile force so that the ribbons curve outward, effectively decoupling them from mechanical contact with the shaft. They still remain, however, in position to act as a touchdown bearing in case of abnormally high transverse accelerations.

  10. Centrifugal Contactor Efficiency Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mincher, Bruce Jay [Idaho National Lab. (INL), Idaho Falls, ID (United States); Tillotson, Richard Dean [Idaho National Lab. (INL), Idaho Falls, ID (United States); Grimes, Travis Shane [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-01-01

    The contactor efficiency of a 2-cm acrylic centrifugal contactor, fabricated by ANL using 3D printer technology was measured by comparing a contactor test run to 5-min batch contacts. The aqueous phase was ~ 3 ppm depleted uranium in 3 M HNO3, and the organic phase was 1 M DAAP/dodecane. Sampling during the contactor run showed that equilibrium was achieved within < 3 minutes. The contactor efficiency at equilibrium was 95% to 100 %, depending on flowrate.

  11. CENTRIFUGAL MEMBRANE FILTRATION

    Energy Technology Data Exchange (ETDEWEB)

    Daniel J. Stepan; Bradley G. Stevens; Melanie D. Hetland

    1999-10-01

    The overall project consists of several integrated research phases related to the applicability, continued development, demonstration, and commercialization of the SpinTek centrifugal membrane filtration process. Work performed during this reporting period consisted of Phase 2 evaluation of the SpinTek centrifugal membrane filtration technology and Phase 3, Technology Partnering. During Phase 1 testing conducted at the EERC using the SpinTek ST-IIL unit operating on a surrogate tank waste, a solids cake developed on the membrane surface. The solids cake was observed where linear membrane velocities were less than 17.5 ft/s and reduced the unobstructed membrane surface area up to 25%, reducing overall filtration performance. The primary goal of the Phase 2 research effort was to enhance filtration performance through the development and testing of alternative turbulence promoter designs. The turbulence promoters were designed to generate a shear force across the entire membrane surface sufficient to maintain a self-cleaning membrane capability and improve filtration efficiency and long-term performance. Specific Phase 2 research activities included the following: System modifications to accommodate an 11-in.-diameter, two-disk rotating membrane assembly; Development and fabrication of alternative turbulence promoter designs; Testing and evaluation of the existing and alternative turbulence promoters under selected operating conditions using a statistically designed test matrix; and Data reduction and analysis; The objective of Phase 3 research was to demonstrate the effectiveness of SpinTek's centrifugal membrane filtration as a pretreatment to remove suspended solids from a liquid waste upstream of 3M's WWL cartridge technology for the selective removal of technetium (Tc).

  12. Centrifugal shot blast system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    This report describes a demonstration of Concrete cleaning, Inc., modified centrifugal shot blast technology to remove the paint coating from concrete flooring. This demonstration is part of the Chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), office of Science and Technology (OST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) CP-5 Research Reactor. The purpose of the LSDP is to demonstrate that using innovative and improved decontamination and decommissioning (D and D) technologies from various sources can result in significant benefits, such as decreased cost and increased health and safety, as compared with baseline D and D technologies. Potential markets exist for the innovative centrifugal shot blast system at the following sites: Fernald Environmental Management Project, Los Alamos, Nevada, Oak Ridge Y-12 and K-25, Paducah, Portsmouth Gaseous Diffusion site, and the Savannah River Site. This information is based on a revision to the OST Linkage Tables dated August 4, 1997.

  13. Central centrifugal cicatricial alopecia.

    Science.gov (United States)

    Whiting, David A; Olsen, Elise A

    2008-01-01

    A progressive scarring alopecia of the central scalp is commonly seen in young to middle-aged females of African descent. It usually starts at the vertex or mid top of the scalp and gradually spreads centrifugally, hence, the unifying term of central centrifugal cicatricial alopecia. The clinical pattern is suggestive of female pattern alopecia, but a lack of follicular pores indicative of scarring is present. It can progress for years before slowly burning out. The etiology is unknown but genetic factors may be important. It is often associated with a history of traumatic hairstyling involving heat, traction, and chemicals. However, most patients of African descent without this disorder have similar styling habits. Nonetheless, avoidance of physical and chemical trauma to the scalp hair, the use of suitable shampoos and conditioners, and the encouragement of natural hairstyles may be helpful. Any infection should be treated. Topical or intralesional corticosteroids and systemic antibiotics may be useful and topical minoxidil should be tried with the hope of preventing further scarring and encouraging regrowth of recovering follicles. Current research into the etiology of this disorder will help to foster much-needed clinical trials of therapeutic agents.

  14. Centrifugal microfluidics for biomedical applications.

    Science.gov (United States)

    Gorkin, Robert; Park, Jiwoon; Siegrist, Jonathan; Amasia, Mary; Lee, Beom Seok; Park, Jong-Myeon; Kim, Jintae; Kim, Hanshin; Madou, Marc; Cho, Yoon-Kyoung

    2010-07-21

    The centrifugal microfluidic platform has been a focus of academic and industrial research efforts for almost 40 years. Primarily targeting biomedical applications, a range of assays have been adapted on the system; however, the platform has found limited commercial success as a research or clinical tool. Nonetheless, new developments in centrifugal microfluidic technologies have the potential to establish wide-spread utilization of the platform. This paper presents an in-depth review of the centrifugal microfluidic platform, while highlighting recent progress in the field and outlining the potential for future applications. An overview of centrifugal microfluidic technologies is presented, including descriptions of advantages of the platform as a microfluidic handling system and the principles behind centrifugal fluidic manipulation. The paper also discusses a history of significant centrifugal microfluidic platform developments with an explanation of the evolution of the platform as it pertains to academia and industry. Lastly, we review the few centrifugal microfluidic-based sample-to-answer analysis systems shown to date and examine the challenges to be tackled before the centrifugal platform can be more broadly accepted as a new diagnostic platform. In particular, fully integrated, easy to operate, inexpensive and accurate microfluidic tools in the area of in vitro nucleic acid diagnostics are discussed.

  15. Unshrouded Centrifugal Turbopump Impeller

    Science.gov (United States)

    Prueger, George; Williams, Morgan; Chen, Wei; Paris, John; Stewart, Eric; Williams, Robert

    1999-01-01

    The ratio of rocket engine thrust to weight is a limiting constraint in placing more payload into orbit at a low cost. A key component of an engine's overall weight is the turbopump weight, Reducing the turbopump weight can result in significant engine weight reduction and hence, increased delivered payload. There are two main types of pumps: centrifugal and axial pumps. These types of pumps can be further sub-divided into those with shrouds and those without shrouds (unshrouded pumps). Centrifugal pumps can achieve the same pump discharge pressure as an axial pump and it requires fewer pump stages and lower pump weight than an axial pump. Also, with unshrouded centrifugal pumps (impeller), the number of stages and weight can be further reduced. However. there are several issues with regard to using an unshrouded impeller: 1) there is a pump performance penalty due to the front open face recirculation flow; 2) there is a potential pump axial thrust problem from the unbalanced front open face and the back shroud face; and, 3) since test data is very linu'ted for this configuration, there is uncertainty in the magnitude and phase of the rotordynamics forces due to the front impeller passage. The purpose of the paper is to discuss the design of an unshrouded impeller and to examine the design's hydrodynamic performance, axial thrust, and rotordynamics performance. The design methodology will also be discussed. This work will help provide some guidelines for unshrouded impeller design. In particular, the paper will discuss the design of three unshrouded impellers - one with 5 full and 5 partial blades (5+5). one with 6+6 blades and one with 8+8 blades. One of these designs will be selected for actual fabrication and flow test. Computational fluid dynamics (CFD) is used to help design and optimize the unshrouded impeller. The relative pump performance penalty is assessed by comparing the CFD results of the unshrouded impeller with the equivalent shrouded impeller for a

  16. [Galileo and centrifugal force].

    Science.gov (United States)

    Vilain, Christiane

    This work intends to focus on Galileo's study of what is now called "centrifugal force," within the framework of the Second Day of his Dialogo written in 1632, rather than on the previously published commentaries on the topic. Galileo proposes three geometrical demonstrations in order to prove that gravity will always overcome centrifugalforce, and that the potential rotation of the Earth, whatever its speed, cannot in any case project objects beyond it. Each of these demonstrations must consequently contain an error and it has seemed to us that the first one had not been understood up until now. Our analysis offers an opportunity to return to Galileo's geometrical representation of dynamical questions; actually, we get an insight into the sophistication of Galileo's practices more than into his mistakes. Our second point, concerning the historiography of the problem, shows an evolution from anachronic critics to more contextual considerations, in the course of the second half of the twentieth century.

  17. Gas centrifuge purge method

    Science.gov (United States)

    Theurich, Gordon R.

    1976-01-01

    1. In a method of separating isotopes in a high speed gas centrifuge wherein a vertically oriented cylindrical rotor bowl is adapted to rotate about its axis within an evacuated chamber, and wherein an annular molecular pump having an intake end and a discharge end encircles the uppermost portion of said rotor bowl, said molecular pump being attached along its periphery in a leak-tight manner to said evacuated chamber, and wherein end cap closure means are affixed to the upper end of said rotor bowl, and a process gas withdrawal and insertion system enters said bowl through said end cap closure means, said evacuated chamber, molecular pump and end cap defining an upper zone at the discharge end of said molecular pump, said evacuated chamber, molecular pump and rotor bowl defining a lower annular zone at the intake end of said molecular pump, a method for removing gases from said upper and lower zones during centrifuge operation with a minimum loss of process gas from said rotor bowl, comprising, in combination: continuously measuring the pressure in said upper zone, pumping gas from said lower zone from the time the pressure in said upper zone equals a first preselected value until the pressure in said upper zone is equal to a second preselected value, said first preselected value being greater than said second preselected value, and continuously pumping gas from said upper zone from the time the pressure in said upper zone equals a third preselected value until the pressure in said upper zone is equal to a fourth preselected value, said third preselected value being greater than said first, second and fourth preselected values.

  18. Pasteurization of grapefruit juice using a centrifugal ultraviolet light irradiator

    Science.gov (United States)

    The pharmaceutical industry uses UV irradiators to inactivate viruses in liquids without heat. The penetration depth of UV in some liquids, such as serum plasma, can be short. To overcome this, very thin films may be produced by centrifugal force, small diameter tubing, or other means. Many liquid f...

  19. Pasteurization of Grapefruit Juice using a Centrifugal Ultraviolet Light Device

    Science.gov (United States)

    The pharmaceutical industry uses UV devices to nonthermally inactivate viruses in liquids. To overcome the low penetration depth of UV in some liquids, such as serum plasma, thin films are formed by centrifugal force. Liquid foods also have low UV penetration depths. Studies are lacking on nontherma...

  20. Microwave assisted centrifuge and related methods

    Science.gov (United States)

    Meikrantz, David H [Idaho Falls, ID

    2010-08-17

    Centrifuge samples may be exposed to microwave energy to heat the samples during centrifugation and to promote separation of the different components or constituents of the samples using a centrifuge device configured for generating microwave energy and directing the microwave energy at a sample located in the centrifuge.

  1. Development of a WES Centrifuge,

    Science.gov (United States)

    1992-09-01

    centrifuge chamber during a long centrifuge flight ANS&A have suggested that a more practical and economical alternative would be to provide thermal barriers around...specifications and costs can be prepared, as follows; (10) Constant temperature and temperature gradient control system based on thermal barriers both...CONTROL SYSTEM Design study by ANS&A for constant temperature and temperature gradient control system based on thermal barriers both external to and

  2. Variable-Speed Instrumented Centrifuges

    Science.gov (United States)

    Chapman, David K.; Brown, Allan H.

    1991-01-01

    Report describes conceptual pair of centrifuges, speed of which varied to produce range of artificial gravities in zero-gravity environment. Image and data recording and controlled temperature and gravity provided for 12 experiments. Microprocessor-controlled centrifuges include video cameras to record stop-motion images of experiments. Potential applications include studies of effect of gravity on growth and on production of hormones in corn seedlings, experiments with magnetic flotation to separate cells, and electrophoresis to separate large fragments of deoxyribonucleic acid.

  3. Hyperbolically Shaped Centrifugal Compressor

    Institute of Scientific and Technical Information of China (English)

    Romuald Puzyrewski; Pawel Flaszy(n)ski

    2003-01-01

    Starting from the classical centrifugal compressor, cone shaped in meridional cross section, two modifications are considered on the basis of results from 2D and 3D flow models. The first modification is the change of the meridional cross section to hyperbolically shaped channel. The second modification, proposed on the basis of 2D axisymmetric solution, concerns the shape of blading. On the strength of this solution the blades are formed as 3D shaped blades, coinciding with the recent tendency in 3D designs. Two aims were considered for the change of meridional compressor shape. The first was to remove the separation zone which appears as the flow tums from axial to radial direction. The second aim is to uniformize the flow at exit of impeller. These two goals were considered within the frame of 2D axisymmetric model. Replacing the cone shaped compressor by a hyperbolically shaped one, the separation at the corner was removed. The disc and shroud shape of the compressor was chosen in the way which satisfies the condition of most uniform flow at the compressor exit. The uniformity of exit flow from the rotor can be considered as the factor which influences the performance of the diffuser following the rotor. In the 2D model a family of stream surfaces of S1 type is given in order to find S2 surfaces which may be identified with the midblade surfaces of compressor blading. A computation of 3D type has been performed in order to establish the relations between 2D and 3D models in the calculation of flow parameters. In the presented example the 2D model appears as the inverse model which leads to 3D shape of blading whereas the 3D model has been used for the direct solution. In the presented example the confrontation of two models, 2D and 3D, leads to a better understanding of the application of these models to the design procedure.

  4. Centrifugation. A theoretical study of oxygen enrichment by centrifugation

    Energy Technology Data Exchange (ETDEWEB)

    Kierkegaard, P.; Raetz, E.

    1998-12-01

    In the present paper we first investigate what happens if we fill a cylinder with air, close it and rotate it. The results show that no matter which peripheral speed is used, it is not possible by means of the radial separation effect alone, to enrich the oxygen concentration from the previous 21% to more then 23.3%, which is of no practical value. In case of a too low enrichment in one centrifuge, the wanted material from this centrifuge can be used as an input for a second centrifuge and so on, in this way forming a cascade of centrifuges. Oxygen will be enriched in each step, until the desired concentration is reached. Cascading was the technology in the very beginning by enrichment plants for uraniumhexaflouride, used for atomic weapons and nuclear power plants. In this study we try to avoid cascading by aiming for higher separation factors. Therefore, we next investigate the possibilities of using a countercurrent centrifuge where in principle the enriched gas is subjected to several centrifugation in the same centrifuge. The calculations show, that in this way it is possible to produce nearly a 100% pure oxygen (polluted with some heavier molecules like argon) in one machine. Our third step was to calculate the amount of oxygen produced per hour. Using a countercurrent centrifuge of the Zippe type, 100 cm high and 20 cm in diameter, it is or will be possible in the near future to produce 17 g enriched air per hour enriched to 50% oxygen. That corresponds to processing 1 m{sup 3} atmospherical air in the period of approximately 24 hours. This is not very impressive. Our fourth step was to estimate the amount of power used for producing this amount of oxygen. A rough, but complicated, estimate shows that the power consumption at the production level will be about the double of the consumption used today. The overall conclusion is, that centrifugation as a production method for oxygen (or nitrogen) will not be competitive with the currently used method in the

  5. Centrifuge-Based Fluidic Platforms

    Science.gov (United States)

    Zoval, Jim; Jia, Guangyao; Kido, Horacio; Kim, Jitae; Kim, Nahui; Madou, Marc

    In this chapter centrifuge-based microfluidic platforms are reviewed and compared with other popular microfluidic propulsion methods. The underlying physical principles of centrifugal pumping in microfluidic systems are presented and the various centrifuge fluidic functions such as valving, decanting, calibration, mixing, metering, heating, sample splitting, and separation are introduced. Those fluidic functions have been combined with analytical measurements techniques such as optical imaging, absorbance and fluorescence spectroscopy and mass spectrometry to make the centrifugal platform a powerful solution for medical and clinical diagnostics and high-throughput screening (HTS) in drug discovery. Applications of a compact disc (CD)-based centrifuge platform analyzed in this review include: two-point calibration of an optode-based ion sensor, an automated immunoassay platform, multiple parallel screening assays and cellular-based assays. The use of modified commercial CD drives for high-resolution optical imaging is discussed as well. From a broader perspective, we compare the technical barriers involved in applying microfluidics for sensing and diagnostic as opposed to applying such techniques to HTS. The latter poses less challenges and explains why HTS products based on a CD fluidic platform are already commercially available, while we might have to wait longer to see commercial CD-based diagnostics.

  6. Centrifugally Stimulated Exospheric Ion Escape at Mercury

    Science.gov (United States)

    Delcourt, Dominique; Seki, K.; Terada, N.; Moore, Thomas E.

    2012-01-01

    We investigate the transport of ions in the low-altitude magnetosphere magnetosphere of Mercury. We show that, because of small spatial scales, the centrifugal effect due to curvature of the E B drift paths can lead to significant particle energization in the parallel direction. We demonstrate that because of this effect, ions with initial speed smaller than the escape speed such as those produced via thermal desorption can overcome gravity and escape into the magnetosphere. The escape route of this low-energy exosphere originating material is largely controlled by the magnetospheric convection rate. This escape route spreads over a narrower range of altitudes when the convection rate increases. Bulk transport of low-energy planetary material thus occurs within a limited region of space once moderate magnetospheric convection is established. These results suggest that, via release of material otherwise gravitationally trapped, the E B related centrifugal acceleration is an important mechanism for the net supply of plasma to the magnetosphere of Mercury.

  7. Generalized anti-centrifugal potential

    Energy Technology Data Exchange (ETDEWEB)

    Dandoloff, Rossen [Laboratoire de Physique Theorique et Modelisation, Universite de Cergy-Pontoise, F-95302 Cergy-Pontoise (France); Jensen, Bjørn [Department of Micro and Nano Systems Technology, Vestfold University College, N-3103 Tønsberg (Norway); Saxena, Avadh, E-mail: avadh@lanl.gov [Theoretical Division and Center for Nonlinear Studies, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2014-01-24

    We generalize the quantum anti-centrifugal potential in the two-dimensional Euclidean plane to two-dimensional surfaces embedded in three-dimensional Euclidean space. We consider the sphere with two caps removed in some detail. We show that quantum particles in this space are “pushed” towards either of the cap boundaries. We also consider the two-dimensional Euclidean plane with an elliptic area removed and compute the quantum anti-centrifugal potential on the elliptic boundary. It is argued that a sufficiently thin electrically conducting nano-wire shaped as an ellipse will exhibit an inhomogeneous charge distribution due to this quantum potential.

  8. MEANS FOR DETERMINING CENTRIFUGE ALIGNMENT

    Science.gov (United States)

    Smith, W.Q.

    1958-08-26

    An apparatus is presented for remotely determining the alignment of a centrifuge. The centrifage shaft is provided with a shoulder, upon which two followers ride, one for detecting radial movements, and one upon the shoulder face for determining the axial motion. The followers are attached to separate liquid filled bellows, and a tube connects each bellows to its respective indicating gage at a remote location. Vibrations produced by misalignment of the centrifuge shaft are transmitted to the bellows, and tbence through the tubing to the indicator gage. This apparatus is particularly useful for operation in a hot cell where the materials handled are dangerous to the operating personnel.

  9. Theory of batchwise centrifugal casting

    NARCIS (Netherlands)

    Biesheuvel, P. Maarten; Nijmeijer, Arian; Verweij, Henk

    1998-01-01

    In batchwise centrifugal casting a cylindrical mold is filled with suspension and rotated rapidly around its axis. This results in the movement of the particulate phase toward the cylinder wall and the formation of a tubular cast. Theory is presented for particle transport in the suspension phase an

  10. CENTRIFUGAL CASTING OF ANTIFRICTION SILUMIN

    Directory of Open Access Journals (Sweden)

    V. Ju. Stetsenko

    2010-01-01

    Full Text Available It is shown that the way of centrifugal casting into water-cooled mould with vertical rotation axis enables to receive hollow slugs with diameter 100–250 mm, with height under 200 mm with wall thickness under 15 mm of antifriction silumin АК15М3, which will replace expensive antifriction bronze.

  11. Design of a centrifugal blood pump: Heart Turcica Centrifugal.

    Science.gov (United States)

    Demir, Onur; Biyikli, Emre; Lazoglu, Ismail; Kucukaksu, Suha

    2011-07-01

    A prototype of a new implantable centrifugal blood pump system named Heart Turcica Centrifugal (HTC) was developed as a left ventricular assist device (LVAD) for the treatment of end-stage cardiac failure. In the development of HTC, effects of blade height and volute tongue profiles on the hydraulic and hemolytic performances of the pump were investigated. As a result, the prototype was manufactured using the best blade height and volute tongue profiles. Performance of the prototype model was experimentally evaluated in a closed-loop flow system using water as the medium. The hydraulic performance requirement of an LVAD (5 L/min flow rate against a pressure difference of 100 mm Hg) was attained at 2800 rpm rotational speed.

  12. Centrifugal separator devices, systems and related methods

    Science.gov (United States)

    Meikrantz, David H.; Law, Jack D.; Garn, Troy G.; Todd, Terry A.; Macaluso, Lawrence L.

    2012-03-20

    Centrifugal separator devices, systems and related methods are described. More particularly, fluid transfer connections for a centrifugal separator system having support assemblies with a movable member coupled to a connection tube and coupled to a fixed member, such that the movable member is constrained to movement along a fixed path relative to the fixed member are described. Also, centrifugal separator systems including such fluid transfer connections are described. Additionally, methods of installing, removing and/or replacing centrifugal separators from centrifugal separator systems are described.

  13. Centrifugal pumps and allied machinery

    CERN Document Server

    Anderson, HH

    1994-01-01

    This book will be of vital interest to all engineers and designers concerned with centrifugal pumps and turbines. Including statistical information derived from 20000 pumps and 700 turbines with capacities of 5gpm to 5000000gpm, this book offers the widest range and scope of information currently available. Statistical analyses suggest practical methods of increasing pump performance and provide valuable data for new design aspects.

  14. Development of the centrifugal pellet injector for JT-60U

    Energy Technology Data Exchange (ETDEWEB)

    Kizu, Kaname; Hiratsuka, Hajime; Ichige, Hisashi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment] [and others

    2001-03-01

    For core fueling of JT-60U plasmas, a repetitive pellet injector which centrifugally accelerates D{sub 2} cubic pellets using a straight rod has been developed. This centrifugal pellet injector can eject trains of up to 40 cubic pellets at frequencies of 1-10 Hz and velocities of 0.3-1.0 km/s. The average pellet mass is 3.6x10{sup 20} atoms/pellet below 0.7 m/s. Key techniques for the development were a mesh structured acceleration component for removing gas sublimated from the pellet and a funnel with an appropriate angle connected just behind the acceleration chamber for introducing the pellet to plasma without destruction. Using the mesh structured components, the horizontal angular distribution of pellets ejected became narrow, because irregular pellet motion caused by sublimated gas was reduced. To investigate the performance of the injector, pellet injection experiments from the low magnetic field side (LFS) were conducted using ohmic heating plasmas. Central fueling and enhanced fueling rate have been observed. D{alpha} intensity around the divertor region was reduced in a pellet injection plasma compared to gas puffing, indicating low recycling rate was maintained with the pellet injection. (author)

  15. Empirical Design Considerations for Industrial Centrifugal Compressors

    Directory of Open Access Journals (Sweden)

    Cheng Xu

    2012-01-01

    Full Text Available Computational Fluid Dynamics (CFD has been extensively used in centrifugal compressor design. CFD provides further optimisation opportunities for the compressor design rather than designing the centrifugal compressor. The experience-based design process still plays an important role for new compressor developments. The wide variety of design subjects represents a very complex design world for centrifugal compressor designers. Therefore, some basic information for centrifugal design is still very important. The impeller is the key part of the centrifugal stage. Designing a highly efficiency impeller with a wide operation range can ensure overall stage design success. This paper provides some empirical information for designing industrial centrifugal compressors with a focus on the impeller. A ported shroud compressor basic design guideline is also discussed for improving the compressor range.

  16. Centrifuge facilities at Technical University of Denmark

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane; Krogsbøll, Anette Susanne; Hededal, Ole

    2008-01-01

    The geotechnical group at the Danish Technical University (DTU) operates a geotechnical beam centrifuge. The centrifuge was build in 1976 and has been upgraded through the years, latest with onboard data and control systems. The centrifuge concept involves an increased gravity field in which...... the physical model is placed and tested. The capabilities of the centrifuge at DTU makes it possible to obtain a scale factor of 75-85 in the tests which equals a soil volume in prototype scale of ø40m and a depth of 36 m. The centrifuge facilities at DTU have through the years been used for testing various...... geotechnical issues, such as suction anchors, tension piles in clay, active earth pressures on sheet piles and group effects for lateral loaded piles. The paper describes physical modelling in general, the centrifuge, present setups and shows samples of obtained results....

  17. Centrifugal quantum states of neutrons

    Science.gov (United States)

    Nesvizhevsky, V. V.; Petukhov, A. K.; Protasov, K. V.; Voronin, A. Yu.

    2008-09-01

    We propose a method for observation of the quasistationary states of neutrons localized near a curved mirror surface. The bounding effective well is formed by the centrifugal potential and the mirror Fermi potential. This phenomenon is an example of an exactly solvable “quantum bouncer” problem that can be studied experimentally. It could provide a promising tool for studying fundamental neutron-matter interactions, as well as quantum neutron optics and surface physics effects. We develop a formalism that describes quantitatively the neutron motion near the mirror surface. The effects of mirror roughness are taken into account.

  18. Virgin Coconut Oil Production by Centrifugation Method

    OpenAIRE

    2014-01-01

    The virgin coconut oil (VCO) production by centrifugation method was studied. The production of VCO was studied by using various centrifugation speed, temperature and time intervals. The results showed that the yield of VCO was 13.53% at 12000rpm, at 120 minutes. The highest yield of VCO was 13.80% at centrifugation temperature of 40oC. The concentration of lauric acid present in the samples with variables of centrifugation temperatures, speed, and time intervals were 0.4543µg, 6.2367µg, and ...

  19. Virgin Coconut Oil Production by Centrifugation Method

    Directory of Open Access Journals (Sweden)

    Y.C.Wong

    2014-03-01

    Full Text Available The virgin coconut oil (VCO production by centrifugation method was studied. The production of VCO was studied by using various centrifugation speed, temperature and time intervals. The results showed that the yield of VCO was 13.53% at 12000rpm, at 120 minutes. The highest yield of VCO was 13.80% at centrifugation temperature of 40oC. The concentration of lauric acid present in the samples with variables of centrifugation temperatures, speed, and time intervals were 0.4543µg, 6.2367µg, and 6.4894µg respectively.

  20. Cavitation Effects in Centrifugal Pumps- A Review

    Directory of Open Access Journals (Sweden)

    Maxime Binama

    2016-05-01

    Full Text Available Cavitation is one of the most challenging fluid flow abnormalities leading to detrimental effects on both the centrifugal pump flow behaviors and physical characteristics. Centrifugal pumps’ most low pressure zones are the first cavitation victims, where cavitation manifests itself in form of pitting on the pump internal solid walls, accompanied by noise and vibration, all leading to the pump hydraulic performance degradation. In the present article, a general description of centrifugal pump performance and related parameters is presented. Based on the literature survey, some light were shed on fundamental cavitation features; where different aspects relating to cavitation in centrifugal pumps were briefly discussed

  1. Centrifugal separators and related devices and methods

    Science.gov (United States)

    Meikrantz, David H.; Law, Jack D.; Garn, Troy G.; Macaluso, Lawrence L.; Todd, Terry A.

    2012-03-06

    Centrifugal separators and related methods and devices are described. More particularly, centrifugal separators comprising a first fluid supply fitting configured to deliver fluid into a longitudinal fluid passage of a rotor shaft and a second fluid supply fitting sized and configured to sealingly couple with the first fluid supply fitting are described. Also, centrifugal separator systems comprising a manifold having a drain fitting and a cleaning fluid supply fitting are described, wherein the manifold is coupled to a movable member of a support assembly. Additionally, methods of cleaning centrifugal separators are described.

  2. The effect of centrifugation speed and time on pre-analytical platelet activation

    DEFF Research Database (Denmark)

    Söderström, Anna Cecilia; Nybo, Mads; Nielsen, Christian

    2016-01-01

    . METHODS: Citrate- and EDTA-anticoagulated blood from healthy volunteers were centrifuged at 80-10,000 g for 5-15 min to prepare plasma and platelet-rich plasma. Pre-analytical platelet activation was assessed by flow cytometric measurement of platelet P-selectin (CD62p) expression. Blood cell counts, mean...... platelet volume (MPV), immature platelet fraction (IPF), and platelet distribution width (PDW) were measured. Platelet aggregation in platelet-rich plasma induced by arachidonic acid (AA), ADP or thrombin receptor activator peptide-6 (TRAP) was tested by 96-well aggregometry. RESULTS: The median percentage...... of platelets expressing P-selectin in citrate- and EDTA-plasma centrifuged at 2000 g for 10 min were 43% [interquartile range (IQR), 38%-53%] and 56% (IQR, 31%-78%), respectively (p=0.82). Platelet-rich plasma prepared at 100-250 g for 10 min had significantly lower platelet P-selectin expression (11%-15%), p...

  3. Improved Recovery and Identification of Membrane Proteins from Rat Hepatic Cells using a Centrifugal Proteomic Reactor*

    Science.gov (United States)

    Zhou, Hu; Wang, Fangjun; Wang, Yuwei; Ning, Zhibin; Hou, Weimin; Wright, Theodore G.; Sundaram, Meenakshi; Zhong, Shumei; Yao, Zemin; Figeys, Daniel

    2011-01-01

    Despite their importance in many biological processes, membrane proteins are underrepresented in proteomic analysis because of their poor solubility (hydrophobicity) and often low abundance. We describe a novel approach for the identification of plasma membrane proteins and intracellular microsomal proteins that combines membrane fractionation, a centrifugal proteomic reactor for streamlined protein extraction, protein digestion and fractionation by centrifugation, and high performance liquid chromatography-electrospray ionization-tandem MS. The performance of this approach was illustrated for the study of the proteome of ER and Golgi microsomal membranes in rat hepatic cells. The centrifugal proteomic reactor identified 945 plasma membrane proteins and 955 microsomal membrane proteins, of which 63 and 47% were predicted as bona fide membrane proteins, respectively. Among these proteins, >800 proteins were undetectable by the conventional in-gel digestion approach. The majority of the membrane proteins only identified by the centrifugal proteomic reactor were proteins with ≥2 transmembrane segments or proteins with high molecular mass (e.g. >150 kDa) and hydrophobicity. The improved proteomic reactor allowed the detection of a group of endocytic and/or signaling receptor proteins on the plasma membrane, as well as apolipoproteins and glycerolipid synthesis enzymes that play a role in the assembly and secretion of apolipoprotein B100-containing very low density lipoproteins. Thus, the centrifugal proteomic reactor offers a new analytical tool for structure and function studies of membrane proteins involved in lipid and lipoprotein metabolism. PMID:21749988

  4. Improved recovery and identification of membrane proteins from rat hepatic cells using a centrifugal proteomic reactor.

    Science.gov (United States)

    Zhou, Hu; Wang, Fangjun; Wang, Yuwei; Ning, Zhibin; Hou, Weimin; Wright, Theodore G; Sundaram, Meenakshi; Zhong, Shumei; Yao, Zemin; Figeys, Daniel

    2011-10-01

    Despite their importance in many biological processes, membrane proteins are underrepresented in proteomic analysis because of their poor solubility (hydrophobicity) and often low abundance. We describe a novel approach for the identification of plasma membrane proteins and intracellular microsomal proteins that combines membrane fractionation, a centrifugal proteomic reactor for streamlined protein extraction, protein digestion and fractionation by centrifugation, and high performance liquid chromatography-electrospray ionization-tandem MS. The performance of this approach was illustrated for the study of the proteome of ER and Golgi microsomal membranes in rat hepatic cells. The centrifugal proteomic reactor identified 945 plasma membrane proteins and 955 microsomal membrane proteins, of which 63 and 47% were predicted as bona fide membrane proteins, respectively. Among these proteins, >800 proteins were undetectable by the conventional in-gel digestion approach. The majority of the membrane proteins only identified by the centrifugal proteomic reactor were proteins with ≥ 2 transmembrane segments or proteins with high molecular mass (e.g. >150 kDa) and hydrophobicity. The improved proteomic reactor allowed the detection of a group of endocytic and/or signaling receptor proteins on the plasma membrane, as well as apolipoproteins and glycerolipid synthesis enzymes that play a role in the assembly and secretion of apolipoprotein B100-containing very low density lipoproteins. Thus, the centrifugal proteomic reactor offers a new analytical tool for structure and function studies of membrane proteins involved in lipid and lipoprotein metabolism.

  5. Continuous chemical processes in centrifugal contact separators

    NARCIS (Netherlands)

    Kwant, Gerard J.; Heeres, Hero

    2008-01-01

    The invention relates to the use of a centrifugal contact-separator for carrying out a non-radioactive reaction in a liquid-liquid emulsion formed from two immiscible liquids. The invention also relates to a process for carrying out a reaction in a centrifugal contact-separator, and to a process for

  6. Rotor for a pyrolysis centrifuge reactor

    DEFF Research Database (Denmark)

    2015-01-01

    The present invention relates to a rotor for a pyrolysis centrifuge reactor, said rotor comprising a rotor body having a longitudinal centre axis, and at least one pivotally mounted blade being adapted to pivot around a pivot axis under rotation of the rotor body around the longitudinal centre axis....... Moreover, the present invention relates to a pyrolysis centrifuge reactor applying such a rotor....

  7. High frequency dynamics in centrifugal compressors

    NARCIS (Netherlands)

    Twerda, A.; Meulendijks, D.; Smeulers, J.P.M.; Handel, R. van den; Lier, L.J. van

    2008-01-01

    Problems with centrifugal compressors relating to high frequency, i.e. Blade passing frequency (BPF) are increasing. Pulsations and vibrations generated in centrifugal compressors can lead to nuisance, due to strong tonal noise, and even breakdown. In several cases the root cause of a failure or a

  8. High frequency dynamics in centrifugal compressors

    NARCIS (Netherlands)

    Twerda, A.; Meulendijks, D.; Smeulers, J.P.M.; Handel, R. van den; Lier, L.J. van

    2008-01-01

    Problems with centrifugal compressors relating to high frequency, i.e. Blade passing frequency (BPF) are increasing. Pulsations and vibrations generated in centrifugal compressors can lead to nuisance, due to strong tonal noise, and even breakdown. In several cases the root cause of a failure or a n

  9. Centrifugal innervation of the mammalian olfactory bulb.

    Science.gov (United States)

    Matsutani, Shinji; Yamamoto, Noboru

    2008-12-01

    Although it has been known for decades that the mammalian olfactory bulb receives a substantial number of centrifugal inputs from other regions of the brain, relatively few data have been available on the function of the centrifugal olfactory system. Knowing the role of the centrifugal projection and how it works is of critical importance to fully understanding olfaction. The centrifugal fibers can be classified into two groups, a group that release neuromodulators, such as noradrenaline, serotonin, or acetylcholine, and a group originating in the olfactory cortex. Accumulating evidence suggests that centrifugal neuromodulatory inputs are associated with acquisition of odor memory. Because the distribution of the terminals on these fibers is diffuse and widespread, the neuromodulatory inputs must affect diverse subsets of bulbar neurons at the same time. In contrast, knowledge of the role of centrifugal fibers from the olfactory cortical areas is limited. Judging from recent morphological evidence, these fibers may modify the activity of neurons located in sparse and discrete loci in the olfactory bulb. Given the modular organization of the olfactory bulb, centrifugal fibers from the olfactory cortex may help coordinate the activities of restricted subsets of neurons belonging to distinct functional modules in an odor-specific manner. Because the olfactory cortex receives inputs from limbic and neocortical areas in addition to inputs from the bulb, the centrifugal inputs from the cortex can modulate odor processing in the bulb in response to non-olfactory as well as olfactory cues.

  10. Centrifuge modelling of offshore monopile foundation

    DEFF Research Database (Denmark)

    Klinkvort, Rasmus Tofte; Hededal, Ole

    2010-01-01

    centrifuge tests on a laterally loaded monopile in dry sand. The prototype dimension of the piles was modelled to a diameter of 1 meter and penetration depth on 6 meter. The test series were designed in order to investigate the scaling laws in the centrifuge both for monotonic and cyclic loading...

  11. Centrifugal membrane filtration -- Task 9

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    The Energy and Environmental Research Center (EERC) has teamed with SpinTek Membrane Systems, Inc., the developer of a centrifugal membrane filtration technology, to demonstrate applications for the SpinTek technology within the US Department of Energy (DOE) Environmental management (EM) Program. The technology uses supported microporous membranes rotating at high rpm, under pressure, to separate suspended and colloidal solids from liquid streams, yielding a solids-free permeate stream and a highly concentrated solids stream. This is a crosscutting technology that falls under the Efficient Separations and Processing Crosscutting Program, with potential application to tank wastes, contaminated groundwater, landfill leachate, and secondary liquid waste streams from other remediation processes, including decontamination and decommissioning systems. Membrane-screening tests were performed with the SpinTek STC-X4 static test cell filtration unit, using five ceramic membranes with different pore size and composition. Based on permeate flux, a 0.25-{micro}m TiO{sub 2}/Al{sub 2}O{sub 3} membrane was selected for detailed performance evaluation using the SpinTek ST-IIL centrifugal membrane filtration unit with a surrogate tank waste solution. An extended test run of 100 hr performed on a surrogate tank waste solution showed some deterioration in filtration performance, based on flux, apparently due to the buildup of solids near the inner portion of the membrane where relative membrane velocities were low. Continued testing of the system will focus on modifications to the shear pattern across the entire membrane surface to affect improved long-term performance.

  12. Evaluation of erythrocyte flow at a bearing gap in a hydrodynamically levitated centrifugal blood pump.

    Science.gov (United States)

    Murashige, Tomotaka; Kosaka, Ryo; Sakota, Daisuke; Nishida, Masahiro; Kawaguchi, Yasuo; Yamane, Takashi; Maruyama, Osamu

    2015-01-01

    We have developed a hydrodynamically levitated centrifugal blood pump for extracorporeal circulatory support. In the blood pump, a spiral groove bearing was adopted for a thrust bearing. In the spiral groove bearing, separation of erythrocytes and plasma by plasma skimming has been postulated to occur. However, it is not clarified that plasma skimming occurs in a spiral groove bearing. The purpose of this study is to verify whether plasma skimming occurs in the spiral groove bearing of a hydrodynamically levitated centrifugal blood pump. For evaluation of plasma skimming in the spiral groove bearing, an impeller levitation performance test using a laser focus displacement meter and a microscopic visualization test of erythrocyte flow using a high-speed microscope were conducted. Bovine blood diluted with autologous plasma to adjust hematocrit to 1.0% was used as a working fluid. Hematocrit on the ridge region in the spiral groove bearing was estimated using image analysis. As a result, hematocrits on the ridge region with gaps of 45 μm, 31 μm, and 25 μm were calculated as 1.0%, 0.6%, and 0.3%, respectively. Maximum skimming efficiency in this study was calculated as 70% with a gap of 25 μm. We confirmed that separation of erythrocyte and plasma occurred in the spiral groove bearing with decrease in bearing gap in a hydrodynamically levitated centrifugal blood pump.

  13. Comparative hemolysis study of clinically available centrifugal pumps.

    Science.gov (United States)

    Naito, K; Suenaga, E; Cao, Z L; Suda, H; Ueno, T; Natsuaki, M; Itoh, T

    1996-06-01

    Centrifugal pumps have become important devices for cardiopulmonary bypass and circulatory assistance. Five types of centrifugal pumps are clinically available in Japan. To evaluate the blood trauma caused by centrifugal pumps, a comparative hemolysis study was performed under identical conditions. In vitro hemolysis test circuits were constructed to operate the BioMedicus BP-80 (Medtronic, BioMedicus), Sarns Delphin (Sarns/3M Healthcare), Isoflow (St. Jude Medical [SJM]), HPM-15 (Nikkiso), and Capiox CX-SP45 (Terumo). The hemolysis test loop consisted of two 1.5 m lengths of polyvinyl chloride tubing with a 3/8-inch internal diameter, a reservoir with a sampling port, and a pump head. All pumps were set to flow at 6 L/min against the total pressure head of 120 mm Hg. Experiments were conducted simultaneously for 6 h at room temperature (21 degrees C) with fresh bovine blood. Blood samples for plasma-free hemoglobin testing were taken, and the change in temperature at the pump outlet port was measured during the experiment. The mean pump rotational speeds were 1,570, 1,374, 1,438, 1,944, and 1,296 rpm, and the normalized indexes of hemolysis were 0.00070, 0.00745, 0.00096, 0.00066, 0.00090 g/100 L for the BP-80, Sarns, SJM, Nikkiso, and Terumo pumps, respectively. The change in temperature at the pump outlet port was the least for the Nikkiso pump (1.8 degrees C) and the most with the SJM pump (3.8 degrees C). This study showed that there is no relationship between the pump rotational speed (rpm) and the normalized index of hemolysis in 5 types of centrifugal pumps. The pump design and number of impellers could be more notable factors in blood damage.

  14. Effect of density gradient centrifugation on reactive oxygen species in human semen.

    Science.gov (United States)

    Takeshima, Teppei; Yumura, Yasushi; Kuroda, Shinnosuke; Kawahara, Takashi; Uemura, Hiroji; Iwasaki, Akira

    2017-06-01

    Density gradient centrifugation can separate motile sperm from immotile sperm and other cells for assisted reproduction, but may also remove antioxidants from seminal plasma, resulting in oxidative stress. Therefore, we investigated reactive oxygen species (ROS) concentrations and distribution in semen before and after density gradient centrifugation. We assessed semen volume, sperm concentration, sperm motility, and ROS levels before and after density gradient centrifugation (300 x g for 20 minutes) in 143 semen samples from 118 patients. The ROS removal rate was evaluated in ROS-positive samples and ROS formation rate in ROS-negative samples. Thirty-eight of 143 untreated samples (26.6%) were ROS-positive; sperm motility was significantly lower in these samples than in ROS-negative samples (p density gradient centrifugation, only seven of the 38 ROS-positive samples (18.42%) exhibited a ROS-positive lower layer (containing motile sperm) with a ROS removal rate of 81.58%, whereas the upper layer was ROS-positive in 24 samples (63.16%). In the ROS-negative group (n = 105), ROS was detected in 19 samples after centrifugation (18.10%, ROS generation rate), of which 18 were ROS-positive only in the upper layer or interface and the other was ROS-positive in both layers. Density gradient centrifugation can separate motile sperm from immotile sperm as well as remove ROS (including newly generated ROS). This data supports the view that density gradient centrifugation can select motile spermatozoa without enhancing oxidative stress. ROS: reactive oxygen species; SOD: superoxide dismutase; GPx: glutathione peroxidase; DNA: deoxyribonucleic acid; DGC: density gradient centrifugation; IUI: intrauterine insemination; IVF: in vitro fertilization; HEPES: 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid; EDTA: ethylenediaminetetraacetic acid; HTF: HEPES-buffered human tubal fluid; IMSI: intracytoplasmic morphologically selected sperm injection; SMAS: sperm motility analyzing

  15. Centrifuge workers study. Phase II, completion report

    Energy Technology Data Exchange (ETDEWEB)

    Wooten, H.D.

    1994-09-01

    Phase II of the Centrifuge Workers Study was a follow-up to the Phase I efforts. The Phase I results had indicated a higher risk than expected among centrifuge workers for developing bladder cancer when compared with the risk in the general population for developing this same type of cancer. However, no specific agent could be identified as the causative agent for these bladder cancers. As the Phase II Report states, Phase I had been limited to workers who had the greatest potential for exposure to substances used in the centrifuge process. Phase II was designed to expand the survey to evaluate the health of all employees who had ever worked in Centrifuge Program Departments 1330-1339 but who had not been interviewed in Phase I. Employees in analytical laboratories and maintenance departments who provided support services for the Centrifuge Program were also included in Phase II. In December 1989, the Oak Ridge Associated Universities (ORAU), now known as Oak Ridge Institute for Science and Education (ORISE), was contracted to conduct a follow-up study (Phase II). Phase H of the Centrifuge Workers Study expanded the survey to include all former centrifuge workers who were not included in Phase I. ORISE was chosen because they had performed the Phase I tasks and summarized the corresponding survey data therefrom.

  16. Gas dynamics in strong centrifugal fields

    Energy Technology Data Exchange (ETDEWEB)

    Bogovalov, S.V.; Kislov, V.A.; Tronin, I.V. [National research nuclear university “MEPhI”, Kashirskoje shosse, 31,115409, Moscow (Russian Federation)

    2015-03-10

    Dynamics of waves generated by scopes in gas centrifuges (GC) for isotope separation is considered. The centrifugal acceleration in the GC reaches values of the order of 106g. The centrifugal and Coriolis forces modify essentially the conventional sound waves. Three families of the waves with different polarisation and dispersion exist in these conditions. Dynamics of the flow in the model GC Iguasu is investigated numerically. Comparison of the results of the numerical modelling of the wave dynamics with the analytical predictions is performed. New phenomena of the resonances in the GC is found. The resonances occur for the waves polarized along the rotational axis having the smallest dumping due to the viscosity.

  17. Dewatering of fine coal using hyperbaric centrifugation

    Energy Technology Data Exchange (ETDEWEB)

    Ramazan Asmatulu; Gerald H. Luttrell; Roe-Hoan Yoon [Virginia Polytechnic Institute and State University, Blacksburg, VA (US). Center for Advanced Separation Technologies

    2005-09-01

    Many coal preparation plants are forced to discard their fine coal because of the inability of existing technologies to reduce the moisture content of this product to an acceptable level. In an effort to overcome this problem, a new mechanical dewatering method has been developed that combines centrifugation with pressure filtration. The process, which may be referred to as hyperbaric centrifugation, is capable of producing a drier product than can be achieved using either filtration or centrifugation alone. The test data obtained from batch experiments show that the new method can reduce cake moisture to 10% or below for many fine coal product streams.

  18. Modeling of Centrifugal Force Field and the Effect on Filling and Solidification in Centrifugal Casting

    Science.gov (United States)

    Sheng, Wenbin; Ma, Chunxue; Gu, Wanli

    2011-06-01

    Based on the steady flow in a tube, a mathematical model has been established for the consideration of centrifuging force field by combining the equations of continuity, conservation of momentum and general energy. Effects of centrifugal field on the filling and solidification are modeled by two accessional terms: centrifugal force and Chorios force. In addition, the transfer of heat by convection is considered to achieve a coupling calculation of velocity field and temperature field. The solution of pressure item is avoided by introducing the stream function ψ(x,y) and the eddy function ξ(x,y). Corresponding difference formats for the simultaneous equations of centrifugal filling, the accessional terms and the solidifying latent heat have been established by the finite difference technique. Furthermore, the centrifugal filling and solidification processes in a horizontal tube are summarized to interpret the mechanism by which internal defects are formed in centrifugal castings.

  19. The application of two-dimensional centrifugation to clinical chemistry testing.

    Science.gov (United States)

    Holen, J T; Schultz, S G; Wong, S T

    1986-01-01

    We have developed a new clinical chemistry analyzer, the VISION System, which uses centrifugal force to separate whole blood, measure reagent and plasma volumes, and complete all steps required for a spectrophotometric analysis. The system is based on a multichambered test pack containing liquid reagents, which can be centrifuged in two planes oriented at right angles to each other. The analyzer regulates the temperature, timing and optical measurements for up to 10 different test packs in the same run. We have demonstrated good precision and accuracy on 6 clinical chemistry analytes, 2 enzymes, potassium and theophylline using this system.

  20. Improved method for measurement of inorganic phosphate in serum with a centrifugal analyzer.

    Science.gov (United States)

    Wentz, P W; Savory, J; Cross, R E

    1976-02-01

    A direct mehtod [Clin. Chim. Acta 46, 113 (1973)] for determination of inorganic phosphate in serum was adapted for use with a centrifugal analyzer. Contamination is minimized and analysis rate maximized by doing the reaction in the reagent wells of the transfer disc and by utilizing the high-speed spectrophotometric and data-reduction capabilities of the centrifugal analyzer. Hemolysis, icterus, and moderate lipemia cause no interference. Grossly lipemic sera and sera from patients with plasma cell dyscrasias can be analyzed by incorporating appropriate blanking and dilution techniques. The method exhibits excellent sensitivity and precision and results correlate well with those from a continuous-flow procedure.

  1. Deburring by centrifugal barrel tumbling

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, L.K.

    1976-08-01

    The reliability of small precision mechanisms greatly depends upon the production of burr-free, sharp-edged parts. Centrifugal barrel finishing (Harperizing) is one of the few processes capable of producing these conditions. Burrs less than 0.001-in. thick by 0.001-in. high (25.4 x 25.4 ..mu..m) can be removed from 303 Se stainless steel, 1018 steel, and 6061-T6 aluminum with dimensional changes in the order of 0.0001-in. (2.54 ..mu..m) and final edge radii of 0.003 in. (76.2 ..mu..m). These conditions can be produced in batch lots in 20 minutes or less. Surface finishes can be reduced from 45 to 25 or 35 microinches (1.15 to 0.68 or 0.89 ..mu..m), with 60-minute cycle times. Stock losses appear to be repeatable within +-0.00006 in. (1.524 ..mu..m). Very small parts receive less action than parts 0.5 in. (12.7 mm) in dia.

  2. Molecular structure and centrifugal distortion in methylthioethyne

    NARCIS (Netherlands)

    Engelsen, D. den

    1969-01-01

    The investigation of the microwave spectra of five isotopic species of methylthioethyne, HCCSCH3 enabled a fairly reliable calculation to be made of bond lengths and angles. The centrifugal distortion parameters are related to molecular vibrations.

  3. Combination Of Investment And Centrifugal Casting

    Science.gov (United States)

    Creeger, Gordon A.

    1994-01-01

    Modifications, including incorporation of centrifugal casting, made in investment-casting process reducing scrap rate. Used to make first- and second-stage high-pressure-fuel-turbopump nozzles, containing vanes with thin trailing edges and other thin sections. Investment mold spun for short time while being filled, and stopped before solidification occurs. Centrifugal force drives molten metal into thin trailing edges, ensuring they are filled. With improved filling, preheat and pour temperatures reduced and solidification hastened so less hot tearing.

  4. Clinical experience with the Sarns centrifugal pump.

    Science.gov (United States)

    Curtis, J J; Walls, J T; Demmy, T L; Boley, T M; Schmaltz, R A; Goss, C F; Wagner-Mann, C C

    1993-07-01

    Since October 1986, we have had experience with 96 Sarns centrifugal pumps in 72 patients (pts). Heparinless left atrial to femoral artery or aorta bypass was used in 14 pts undergoing surgery on the thoracic aorta with 13 survivors (93%). No paraplegia or device-related complications were observed. In 57 patients, the Sarns centrifugal pump was used as a univentricular (27 pts) or biventricular (30 pts) cardiac assist device for postcardiotomy cardiogenic shock. In these patients, cardiac assist duration ranged from 2 to 434 h with a hospital survival rate of 29% in those requiring left ventricular assist and 13% in those requiring biventricular assist. Although complications were ubiquitous in this mortally ill patient population, in 5,235 pump-hours, no pump thrombosis was observed. Hospital survivors followed for 4 months to 6 years have enjoyed an improved functional class. We conclude that the Sarns centrifugal pump is an effective cardiac assist device when used to salvage patients otherwise unweanable from cardiopulmonary bypass. Partial left ventricular bypass using a centrifugal pump has become our procedure of choice for unloading the left ventricle and for maintenance of distal aortic perfusion pressure when performing surgery on the thoracic aorta. This clinical experience with the Sarns centrifugal pump appears to be similar to that reported with other centrifugal assist devices.

  5. Platelet-rich plasma generated via the three centrifugalization method and its impact on adipose tissuederived stem cells proliferation and mineralization%富血小板血浆的三次离心法制备及其对脂肪干细胞增殖、成骨矿化的影响

    Institute of Scientific and Technical Information of China (English)

    徐燕; 叶眉; 陈芳; 姜大川; 孙晓瑜; 林潇; 沈继龙

    2011-01-01

    Objective The study investigated an effective method of generating platelet-rich plasma(PRP) and evaluated the impact of different concentrations of PRP on adipose tissue-derived stem cell (ADSC) proliferation and mineralization in vitro. Methods 40 mL whole blood was collected from 3 healthy Beagle dogs and then PRP was separated by the two eentrifugalization method and the three centrifugalization method respectively. Then the platelet was counted and analyzed. ADSC were exposed to DMEM medium with various concentrations of PRP (5%, 10%, 15%, 20%) respectively. After incubation of 48, 72, 96 h, the proliferations of ADSC were measured.ADSC were cultured in osteoblasts induced medium and osteoblasts induced medium with PRP (5%, 10%, 15%,20%) respectively, The osteogenetie expression of ADSC and the influence on its osteogenesis mineralization of PRP were observed. Results The number of platelet from the three centrifugalization method was more than that from the two centrifugalization method. The role on various concentrations of PRP on cell proliferation was more significant than that of negative control (P<0.001), the differences between various concentrations of PRP groups had a statistical significance(P<0.001). The group of 96 h, 15% PRP reached to peak value in ADSC proliferation. The quantity of mineralization node in ADSC was maximized under the condition of osteoblasts induced medium with 20% PRP. Conclusion The three centrifugalization method was more efficient than the two centrifugalization method. PRP promoted ADSC proliferation in both the dose- and time- dependent ways while PRP improved ADSC mineralization in the dose-dependent way only.%目的 探索高效制备富血小板血浆(PRP)的方法,并观察不同体积分数的PRP对Beagle犬脂肪干细胞(ADSC)体外增殖及其向成骨细胞分化的影响.方法 抽取3只Beagle犬静脉血各40 mL,分别用传统的二次离心法和改良的三次离心法制备PRP,进

  6. Effects of centrifugation on transmembrane water loss from normal and pathologic erythrocytes

    Energy Technology Data Exchange (ETDEWEB)

    Kaperonis, A.A.; Chien, S.

    1989-02-01

    Plasma /sup 125/I-albumin was used as a marker of extracellular dilution in order to study the effect of high-speed centrifugation on transmembrane water distribution in several types of human red cells, including normal (AA), hemoglobin variants (beta A, AS, SC, beta S, and SS), and those from patients with hereditary spherocytosis. SS and AA erythrocytes were also examined for changes in intracellular hemoglobin concentration of three different density fractions and with increasing duration of spin. The minimum force and duration of centrifugation required to impair water permeability were found to vary with the red cell type, the anticoagulant used (heparin or EDTA), the initial hematocrit of the sample centrifuged, as well as among the individual erythrocyte fractions within the same sample. When subjecting pathologic erythrocytes to high-speed centrifugation, the /sup 125/I-albumin dilution technique can be used to determine whether the centrifugation procedure has led to an artifactual red cell water loss and to correct for this when it does occur. An abnormal membrane susceptibility to mechanical stress was demonstrated in erythrocytes from patients with hereditary spherocytosis and several hemoglobinopathies.

  7. A Review of Biomedical Centrifugal Microfluidic Platforms

    Directory of Open Access Journals (Sweden)

    Minghui Tang

    2016-02-01

    Full Text Available Centrifugal microfluidic or lab-on-a-disc platforms have many advantages over other microfluidic systems. These advantages include a minimal amount of instrumentation, the efficient removal of any disturbing bubbles or residual volumes, and inherently available density-based sample transportation and separation. Centrifugal microfluidic devices applied to biomedical analysis and point-of-care diagnostics have been extensively promoted recently. This paper presents an up-to-date overview of these devices. The development of biomedical centrifugal microfluidic platforms essentially covers two categories: (i unit operations that perform specific functionalities, and (ii systems that aim to address certain biomedical applications. With the aim to provide a comprehensive representation of current development in this field, this review summarizes progress in both categories. The advanced unit operations implemented for biological processing include mixing, valving, switching, metering and sequential loading. Depending on the type of sample to be used in the system, biomedical applications are classified into four groups: nucleic acid analysis, blood analysis, immunoassays, and other biomedical applications. Our overview of advanced unit operations also includes the basic concepts and mechanisms involved in centrifugal microfluidics, while on the other hand an outline on reported applications clarifies how an assembly of unit operations enables efficient implementation of various types of complex assays. Lastly, challenges and potential for future development of biomedical centrifugal microfluidic devices are discussed.

  8. In-vitro assessment of centrifugal pumps for ventricular assist.

    Science.gov (United States)

    Jakob, H; Kutschera, Y; Palzer, B; Prellwitz, W; Oelert, H

    1990-08-01

    Currently two major types of centrifugal pumps are commercially available for ventricular assist: the Biomedicus-cone (Group I) and the Centrimed-impeller pump (now Sarns 3M) (Group II). To compare them for blood trauma and hemolysis, an in-vitro experiment was designed with a Stöckert roller pump as a standard control (Group III). The in-vitro circuit was constructed consisting of a pump head, electromagnetic flow probe, polyvinyl chloride tubing and a reservoir, identical for all groups. Human ACD blood was used for priming and was circulated with a flow rate of 2 L/min for 24 h. Blood samples were taken at 0, 1, 3, 6, 12, and 24 h and zero control values were subtracted from the resulting data per time interval. Among the 16 parameters studied, a highly significant difference in favor of Group I was found for glutamate oxalacetate transaminase (GOT) and lactate dehydrogenase (p less than 0.0001) and for the free plasma hemoglobin (p less than 0.0001) after 12 and 24 h, respectively. The hemolytic index (Allen) again was lowest for group I in contrast to Groups II and III (0.012 versus 0.060 and 1.70) after 24 h. All other parameters studied did not render significant differences between the systems tested. The authors conclude that the Biomedicus pump currently is the least traumatic centrifugal pump for ventricular assist.

  9. Analysis of Secondary Flows in Centrifugal Impellers

    Directory of Open Access Journals (Sweden)

    Brun Klaus

    2005-01-01

    Full Text Available Secondary flows are undesirable in centrifugal compressors as they are a direct cause for flow (head losses, create nonuniform meridional flow profiles, potentially induce flow separation/stall, and contribute to impeller flow slip; that is, secondary flows negatively affect the compressor performance. A model based on the vorticity equation for a rotating system was developed to determine the streamwise vorticity from the normal and binormal vorticity components (which are known from the meridional flow profile. Using the streamwise vorticity results and the small shear-large disturbance flow method, the onset, direction, and magnitude of circulatory secondary flows in a shrouded centrifugal impeller can be predicted. This model is also used to estimate head losses due to secondary flows in a centrifugal flow impeller. The described method can be employed early in the design process to develop impeller flow shapes that intrinsically reduce secondary flows rather than using disruptive elements such as splitter vanes to accomplish this task.

  10. Possible segregation caused by centrifugal titanium casting.

    Science.gov (United States)

    Watanabe, K; Okawa, S; Kanatani, M; Nakano, S; Miyakawa, O; Kobayashi, M

    1996-12-01

    The possibility of the segregation under solidification process using a centrifugal casting machine was investigated using an electron probe microanalyzer with elemental distribution map, line analysis and quantitative analysis. When a very small quantity of platinum was added to local molten titanium during the casting process, macroscopic segregation was observed under conditions of density difference of 0.1 g/cm3 at the most, confirming that the centrifugal force of the casting machine is extremely strong. When a Ti-6Al-4V alloy was cast, however, no macroscopic segregation was observed. The centrifugal force of the casting machine examined in the present study hardly results in the body-force segregation in this titanium alloy.

  11. Centrifugal Sieve for Size-Segregation/ Beneficiation of Regolith Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Utilizing centrifugal force as the primary body-force, combined with both shearing flow and vibratory motion the proposed centrifugal-sieve separators can provide...

  12. Engineering design of centrifugal casting machine

    Science.gov (United States)

    Kusnowo, Roni; Gunara, Sophiadi

    2017-06-01

    Centrifugal casting is a metal casting process in which metal liquid is poured into a rotating mold at a specific temperature. Given round will generate a centrifugal force that will affect the outcome of the casting. Casting method is suitable in the manufacture of the casting cylinder to obtain better results. This research was performed to design a prototype machine by using the concept of centrifugal casting. The design method was a step-by-step systematic approach in the process of thinking to achieve the desired goal of realizing the idea and build bridges between idea and the product. Design process was commenced by the conceptual design phase and followed by the embodiment design stage and detailed design stage. With an engineering design process based on the method developed by G. E. Dieter, draft prototype of centrifugal casting machine with dimension of 550×450×400 mm, ¼ HP motor power, pulley and belt mechanism, diameter of 120-150mm, simultaneously with the characteristics of simple casting product, easy manufacture and maintenance, and relatively inexpensive, was generated.

  13. Positive feedback stabilization of centrifugal compressor surge

    NARCIS (Netherlands)

    Willems, Frank; Heemels, W.P.M.H.; de Jager, Bram; Stoorvogel, Antonie Arij

    2002-01-01

    Stable operation of axial and centrifugal compressors is limited towards low mass flows due to the occurrence of surge. The stable operating region can be enlarged by active control. In this study, we use a control valve which is fully closed in the desired operating point and only opens to stabiliz

  14. Differential white cell count by centrifugal microfluidics.

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.

    2010-07-01

    We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generation of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.

  15. Centrifugal Casting of Tubular Perovskite Membranes

    NARCIS (Netherlands)

    Mertins, Frederic H.B.; Kruidhof, Henk; Bouwmeester, Henny J.M.

    2005-01-01

    Dense tubular membranes were produced by centrifugal casting of an aqueous suspension, containing powder particles of the mixed-conducting perovskite La0.5Sr0.5CoO3−δ and a dispersant. The resulting green bodies were dried and sintered to produce tubes with a maximum length of 12 cm, having a relat

  16. Evaluation of an improved centrifugal casting machine.

    Science.gov (United States)

    Donovan, T E; White, L E

    1985-05-01

    A Type III gold alloy, a silver-palladium alloy, and a base metal alloy were cast in two different centrifugal casting machines. With the number of complete cast mesh squares as an indicator of castability, the Airspin casting machine produced superior castings with all three alloys. The base metal alloy produced the greatest number of complete squares with both casting machines.

  17. Pressure distribution in centrifugal dental casting.

    Science.gov (United States)

    Nielsen, J P

    1978-02-01

    Equations are developed for liquid metal pressure in centrifugal dental casting, given the instantaneous rotational velocity, density, and certain dimensions of the casting machine and casting pattern. A "reference parabola" is introduced making the fluid pressure concept more understandable. A specially designed specimen demonstrates experimentally the reference parabola at freezing.

  18. Centrifugal Pump Experiment for Chemical Engineering Undergraduates

    Science.gov (United States)

    Vanderslice, Nicholas; Oberto, Richard; Marrero, Thomas R.

    2012-01-01

    The purpose of this paper is to describe a Centrifugal Pump Experiment that provided an experiential learning experience to chemical engineering undergraduates at the University of Missouri in the spring of 2010 in the Unit Operations Laboratory course. Lab equipment was used by senior students with computer-based data and control technology. In…

  19. Positive feedback stabilization of centrifugal compressor surge

    NARCIS (Netherlands)

    Willems, Frank; Heemels, W.P.M.H.; de Jager, Bram; Stoorvogel, Antonie Arij

    Stable operation of axial and centrifugal compressors is limited towards low mass flows due to the occurrence of surge. The stable operating region can be enlarged by active control. In this study, we use a control valve which is fully closed in the desired operating point and only opens to

  20. Performance of a Centrifugal Slurry Pump

    Directory of Open Access Journals (Sweden)

    Hawas Yahya Bajawi

    2014-02-01

    Full Text Available The aim of this study was to experimentally investigate the effect of speed, concentration and size of slurry on the performance of a centrifugal pump. For this purpose a facility was built where the performance of a centrifugal slurry pump was examined using aggregate slurry. Three sizes of slurry with three concentrations and at three impeller speeds were used for the performance investigations of a centrifugal slurry pump. As a reference performance the performance of centrifugal slurry pump was also tested with clean water. The performance of pump has been reported as variations of head, power and efficiency at various flow rates along with the system characteristics of the pump. The results reveal that the pump performance is grossly affected by the type of slurry, its concentration and size. Besides this the variation in speed also affects the performance as is observed in pumps with water. The maximum decrease in the head, with respect to clear water, at the operating point was found to be 47% for aggregate for size 20 mm, 15% concentration and 2600 rpm. The maximum decrement in efficiency at operating point for aggregate was found to be 47% for 4 mm size, 15% concentration and at 2200 rpm. The power increment requirement for aggregate was 9% for 4 mm size, 15% concentration and 2600 rpm.

  1. Centrifugal Pump Experiment for Chemical Engineering Undergraduates

    Science.gov (United States)

    Vanderslice, Nicholas; Oberto, Richard; Marrero, Thomas R.

    2012-01-01

    The purpose of this paper is to describe a Centrifugal Pump Experiment that provided an experiential learning experience to chemical engineering undergraduates at the University of Missouri in the spring of 2010 in the Unit Operations Laboratory course. Lab equipment was used by senior students with computer-based data and control technology. In…

  2. Predicting Droplet Formation on Centrifugal Microfluidic Platforms

    Science.gov (United States)

    Moebius, Jacob Alfred

    Centrifugal microfluidics is a widely known research tool for biological sample and water quality analysis. Currently, the standard equipment used for such diagnostic applications include slow, bulky machines controlled by multiple operators. These machines can be condensed into a smaller, faster benchtop sample-to-answer system. Sample processing is an important step taken to extract, isolate, and convert biological factors, such as nucleic acids or proteins, from a raw sample to an analyzable solution. Volume definition is one such step. The focus of this thesis is the development of a model predicting monodispersed droplet formation and the application of droplets as a technique for volume definition. First, a background of droplet microfluidic platforms is presented, along with current biological analysis technologies and the advantages of integrating such technologies onto microfluidic platforms. Second, background and theories of centrifugal microfluidics is given, followed by theories relevant to droplet emulsions. Third, fabrication techniques for centrifugal microfluidic designs are discussed. Finally, the development of a model for predicting droplet formation on the centrifugal microfluidic platform are presented for the rest of the thesis. Predicting droplet formation analytically based on the volumetric flow rates of the continuous and dispersed phases, the ratios of these two flow rates, and the interfacial tension between the continuous and dispersed phases presented many challenges, which will be discussed in this work. Experimental validation was completed using continuous phase solutions of different interfacial tensions. To conclude, prospective applications are discussed with expected challenges.

  3. Centrifugal Compressors, Flow Phenomena and Performance.

    Science.gov (United States)

    1980-11-01

    centrifugal compression. Clearly the temperature-entropy diagram aids understanding of the compression procesoes , as was appreciated by Vavra [11]. We now...features may provide small apparent improvements in compressor performance, but are often accompanied by minor parasitic performance penal - ties; for

  4. Centrifugal Modelling of Soil Structures. Part I. Centrifugal Modelling of Slope Failures.

    Science.gov (United States)

    1979-03-01

    section of the clay itself, which was visible to the camera. This latter set of stripes was applied using a variety of trial materials: kaolin powder...investigated slope instability of open cast sulphur and manganese mine waste embankments in the Ukraine, over six years, using the centrifugal modelling...model MW21, and altering the model soil interface with f the centrifuge strongbox by introducing an underlayer of preconsolidated kaolin in two models

  5. System-level network simulation for robust centrifugal-microfluidic lab-on-a-chip systems.

    Science.gov (United States)

    Schwarz, I; Zehnle, S; Hutzenlaub, T; Zengerle, R; Paust, N

    2016-05-10

    Centrifugal microfluidics shows a clear trend towards a higher degree of integration and parallelization. This trend leads to an increase in the number and density of integrated microfluidic unit operations. The fact that all unit operations are processed by the same common spin protocol turns higher integration into higher complexity. To allow for efficient development anyhow, we introduce advanced lumped models for network simulations in centrifugal microfluidics. These models consider the interplay of centrifugal and Euler pressures, viscous dissipation, capillary pressures and pneumatic pressures. The simulations are fast and simple to set up and allow for the precise prediction of flow rates as well as switching and valving events. During development, channel and chamber geometry variations due to manufacturing tolerances can be taken into account as well as pipetting errors, variations of contact angles, compliant chamber walls and temperature variations in the processing device. As an example of considering these parameters during development, we demonstrate simulation based robustness analysis for pneumatic siphon valving in centrifugal microfluidics. Subsequently, the influence of liquid properties on pumping and valving is studied for four liquids relevant for biochemical analysis, namely, water (large surface tension), blood plasma (large contact angle hysteresis), ethanol/water (highly wetting) and glycerine/water (highly viscous). In a second example, we derive a spin protocol to attain a constant flow rate under varying pressure conditions. Both examples show excellent agreement with experimental validations.

  6. Evolution of microstructure in centrifugal cast Al-Cu alloy

    Directory of Open Access Journals (Sweden)

    Sui Yanwei

    2010-02-01

    Full Text Available In this research, the effects of centrifugal radius and mould rotation speed on microstructure in centrifugal-cast Al-Cu alloy have been investigated. The results show that, with increase of the centrifugal radius or mould rotation speed, the grain size of centrifugal-cast Al-Cu alloy decreases gradually, while the content of white phases containing the Al2Cu precipitated from α-phase, divorced eutectic and regular eutectic microstructure increases, leading to higher Cu macrosegregation. The variation level of microstructure in centrifugal-cast Al-Cu alloy at 600 rpm of mould rotation speed is greater than that at 300 rpm.

  7. Fractal structures in centrifugal flywheel governor system

    Science.gov (United States)

    Rao, Xiao-Bo; Chu, Yan-Dong; Lu-Xu; Chang, Ying-Xiang; Zhang, Jian-Gang

    2017-09-01

    The global structure of nonlinear response of mechanical centrifugal governor, forming in two-dimensional parameter space, is studied in this paper. By using three kinds of phases, we describe how responses of periodicity, quasi-periodicity and chaos organize some self-similarity structures with parameters varying. For several parameter combinations, the regular vibration shows fractal characteristic, that is, the comb-shaped self-similarity structure is generated by alternating periodic response with intermittent chaos, and Arnold's tongues embedded in quasi-periodic response are organized according to Stern-Brocot tree. In particular, a new type of mixed-mode oscillations (MMOs) is found in the periodic response. These unique structures reveal the natural connection of various responses between part and part, part and the whole in parameter space based on self-similarity of fractal. Meanwhile, the remarkable and unexpected results are to contribute a valid dynamic reference for practical applications with respect to mechanical centrifugal governor.

  8. Fault Detection and Isolation in Centrifugal Pumps

    DEFF Research Database (Denmark)

    Kallesøe, Carsten

    Centrifugal pumps are used in a variety of different applications, such as water supply, wastewater, and different industrial applications. Some pump installations are crucial for the applications to work. Failures can lead to substantial economic losses and can influence the life of many people...... when they occur. Therefore, detection of faults, if possible in an early stage, and isolation of their causes are of great interest. Especially fault detection, which can be used for predictive maintenance, can decrease working expenses and increase the reliability of the application in which the pump...... is placed. The topic of this work is Fault Detection and Identification in centrifugal pumps. Different approaches are developed with special focus on robustness. Robustness with respect to disturbances, unknown parts of the system, and parameter variations are considered. All developed algorithms...

  9. Cavitation pulse extraction and centrifugal pump analysis

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Hong Lind Shaoran [University of Electronic Science and Technology of China, Chengdu (China); Yu, Bo; Qing, Biao [Xihua University, Chengdu (China)

    2017-03-15

    This study extracted cavitation pulses from hydrophone signals sampled in a centrifugal pump and analyzed their characteristics. The modified and simplified Empirical mode decomposition (EMD) algorithm was proposed for extracting cavitation pulses from strong background noise. Experimental results showed that EMD can effectively suppress noise and obtain clear cavitation pulses, facilitating the identification of the number of pulses associated with the degree of cavitation. The cavitation characteristics were modeled to predict the value of incipient cavitation. Then, we proposed a method for detecting the wear of the impeller surface. That is, the information on the impeller surface of the centrifugal pump, including the roughness of the impeller surface and its wear trends, were quantified based on the net positive suction head available of incipient cavitation. The findings indicate that the proposed technique is suitable for condition monitoring of the pump.

  10. Meridional Considerations of the Centrifugal Compressor Development

    Directory of Open Access Journals (Sweden)

    C. Xu

    2012-01-01

    Full Text Available Centrifugal compressor developments are interested in using optimization procedures that enable compressor high efficiency and wide operating ranges. Recently, high pressure ratio and efficiency of the centrifugal compressors require impeller design to pay attention to both the blade angle distribution and the meridional profile. The geometry of the blades and the meridional profile are very important contributions of compressor performance and structure reliability. This paper presents some recent studies of meridional impacts of the compressor. Studies indicated that the meridional profiles of the impeller impact the overall compressor efficiency and pressure ratio at the same rotational speed. Proper meridional profiles can improve the compressor efficiency and increase the overall pressure ratio at the same blade back curvature.

  11. A vibration model for centrifugal contactors

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, R.A.; Wasserman, M.O.; Wygmans, D.G.

    1992-11-01

    Using the transfer matrix method, we created the Excel worksheet ``Beam`` for analyzing vibrations in centrifugal contactors. With this worksheet, a user can calculate the first natural frequency of the motor/rotor system for a centrifugal contactor. We determined a typical value for the bearing stiffness (k{sub B}) of a motor after measuring the k{sub B} value for three different motors. The k{sub B} value is an important parameter in this model, but it is not normally available for motors. The assumptions that we made in creating the Beam worksheet were verified by comparing the calculated results with those from a VAX computer program, BEAM IV. The Beam worksheet was applied to several contactor designs for which we have experimental data and found to work well.

  12. Free of centrifugal acceleration spacetime - Geodesics

    CERN Document Server

    Culetu, Hristu

    2013-01-01

    A static spacetime with no centrifugal repulsion, previously studied by Dadhich, is investigate in this paper. The source of curvature is considered to be an anisotropic fluid with $\\rho = -p_{r}$ and constant angular pressures. The positive parameter from the line-element is interpreted as the invariant acceleration of a static observer. We found that the Tolman-Komar gravitational energy is finite everywhere. The timelike and null geodesics of the spacetime are examined.

  13. Analysis of performance for centrifugal steam compressor

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Seung Hwan; Ryu, Chang Kook; Ko, Han Seo [Sungkyunkwan University, Suwon (Korea, Republic of)

    2016-12-15

    In this study, mean streamline and Computational fluid dynamics (CFD) analyses were performed to investigate the performance of a small centrifugal steam compressor using a latent heat recovery technology. The results from both analysis methods showed good agreement. The compression ratio and efficiency of steam were found to be related with those of air by comparing the compression performances of both gases. Thus, the compression performance of steam could be predicted by the compression performance of air using the developed dimensionless parameters.

  14. Centrifugal shot blasting. Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    1999-07-01

    At the US Department of Energy (DOE) Fernald Environmental Management Project (FEMP), the Facilities Closure and Demolition Projects Integrated Remedial Design/Remedial Action (RD/RA) work plan calls for the removal of one inch (1 in) depth of concrete surface in areas where contamination with technetium-99 has been identified. This report describes a comparative demonstration between two concrete removal technologies: an innovative system using Centrifugal Shot Blasting (CSB) and a modified baseline technology called a rotary drum planer.

  15. Analysis of Secondary Flows in Centrifugal Impellers

    OpenAIRE

    2005-01-01

    Secondary flows are undesirable in centrifugal compressors as they are a direct cause for flow (head) losses, create nonuniform meridional flow profiles, potentially induce flow separation/stall, and contribute to impeller flow slip; that is, secondary flows negatively affect the compressor performance. A model based on the vorticity equation for a rotating system was developed to determine the streamwise vorticity from the normal and binormal vorticity components (which are known from the me...

  16. Predicting Droplet Formation on Centrifugal Microfluidic Platforms

    OpenAIRE

    Moebius, Jacob Alfred

    2015-01-01

    Centrifugal microfluidics is a widely known research tool for biological sample and water quality analysis. Currently, the standard equipment used for such diagnostic applications include slow, bulky machines controlled by multiple operators. These machines can be condensed into a smaller, faster benchtop sample-to-answer system.Sample processing is an important step taken to extract, isolate, and convert biological factors, such as nucleic acids or proteins, from a raw sample to an analyzabl...

  17. In-vivo Centrifugation of Drosophila Embryos

    OpenAIRE

    Tran, Susan L.; Welte, Michael A.

    2010-01-01

    A major strategy for purifying and isolating different types of intracellular organelles is to separate them from each other based on differences in buoyant density. However, when cells are disrupted prior to centrifugation, proteins and organelles in this non-native environment often inappropriately stick to each other. Here we describe a method to separate organelles by density in intact, living Drosophila embryos. Early embryos before cellularization are harvested from population cages, an...

  18. Numerical Simulation of a Centrifugal Compressor

    Directory of Open Access Journals (Sweden)

    S.M.Swamy

    2017-06-01

    Full Text Available In this paper, the tip clearance effects on flow field of a low speed centrifugal compressor without and with partial shroud (PS fitted on to the rotor blade tip at three values of tip clearance, viz. = 2.2%, 5.1% and 7.9% of rotor blade height at the exit at three flow coefficients, namely, = 0.18, 0.28, and 0.34, was studied. Based on the theory of computational fluid dynamics (CFD, performance curves and parameter distributions of the compressor were obtained from the 3-D numerical simulation by using ANSYS CFX 15.0. The centrifugal compressor in aerodynamic requirement is that edge velocities along the impeller channel passage surfaces like hub, shroud, pressure and suction surfaces vary smoothly without sudden decelerations, which cause flow separation leading to losses. Using the periodic boundaries and defined flow conditions at inflow / exit flow and blade rotations, the turbulent viscous flow between blade channels are computed. The efficiency related parameters using average quantities, besides flow pattern in terms of velocities, streamlines and pressure distribution on blade surfaces are graphically interpreted. An attempt is also made to study the influence of pressure loads on structural deformations in the chosen blade profile. This paper highlights aero-mechanical features of centrifugal impeller obtained from several numerical simulations, which are expected to provide a sound basis for further investigations

  19. Shallow water model for horizontal centrifugal casting

    Science.gov (United States)

    Boháček, J.; Kharicha, A.; Ludwig, A.; Wu, M.

    2012-07-01

    A numerical model was proposed to simulate the solidification process of an outer shell of work roll made by the horizontal centrifugal casting technique. Shallow water model was adopted to solve the 2D average flow dynamics of melt spreading and the average temperature distribution inside the centrifugal casting mould by considering the centrifugal force, Coriolis force, viscous force due to zero velocity on the mould wall, gravity, and energy transport by the flow. Additionally, a 1D sub-model was implemented to consider the heat transfer in the radial direction from the solidifying shell to the mould. The solidification front was tracked by fulfilling the Stefan condition. Radiative and convective heat losses were included from both, the free liquid surface and the outer wall of the mould. Several cases were simulated with the following assumed initial conditions: constant height of the liquid metal (10, 20, and 30 mm), uniform temperature of the free liquid surface (1755 K). The simulation results have shown that while the solidification front remained rather flat, the free surface was disturbed by waves. The amplitude of waves increased with the liquid height. Free surface waves diminished as the solidification proceeded.

  20. Centrifugal compressor design choices for chillers

    Energy Technology Data Exchange (ETDEWEB)

    Brasz, J.J. [United Technologies Carrier, New York, NY (United States)

    1999-07-01

    The use of centrifugal compressors in the air conditioning and refrigeration industry is currently limited to large water cooled chillers varying in size from about 0.5 to 6 MW cooling capacity. These systems are primarily used for comfort or process cooling applications. All systems try to chill relatively large amounts of indoor or process water by a few degrees Celsius in a refrigerant evaporator. The heat removed from the chilled water is released together with the heat of compression in a refrigerant condenser to cooling tower water, from where it is discharged to the atmosphere. Different centrifugal compressor design concepts are used by the various chiller manufacturers: single-stage versus multi-stage, vaneless versus vaned diffuser, hermetic versus open-drive motors, shrouded versus open impellers, fixed versus variable diffuser geometry, low- versus high-pressure refrigerant. This variability seems strange for a mature industry like the air conditioning and refrigeration industry. This paper will show that the reason for this variability is the product compromise between the various conflicting system requirements with respect to size, cost, efficiency and refrigerant choice. The different system applications of the chillers (e.g. comfort cooling in a equatorial region versus process cooling in a moderate climate zone) play another major role in selecting an optimal centrifugal compression concept. Some general recommendations will be given for applications where a clear choice can be made. (Author)

  1. CFD Simulation of Annular Centrifugal Extractors

    Directory of Open Access Journals (Sweden)

    S. Vedantam

    2012-01-01

    Full Text Available Annular centrifugal extractors (ACE, also called annular centrifugal contactors offer several advantages over the other conventional process equipment such as low hold-up, high process throughput, low residence time, low solvent inventory and high turn down ratio. The equipment provides a very high value of mass transfer coefficient and interfacial area in the annular zone because of the high level of power consumption per unit volume and separation inside the rotor due to the high g of centrifugal field. For the development of rational and reliable design procedures, it is important to understand the flow patterns in the mixer and settler zones. Computational Fluid Dynamics (CFD has played a major role in the constant evolution and improvements of this device. During the past thirty years, a large number of investigators have undertaken CFD simulations. All these publications have been carefully and critically analyzed and a coherent picture of the present status has been presented in this review paper. Initially, review of the single phase studies in the annular region has been presented, followed by the separator region. In continuation, the two-phase CFD simulations involving liquid-liquid and gas-liquid flow in the annular as well as separator regions have been reviewed. Suggestions have been made for the future work for bridging the existing knowledge gaps. In particular, emphasis has been given to the application of CFD simulations for the design of this equipment.

  2. In-vivo centrifugation of Drosophila embryos.

    Science.gov (United States)

    Tran, Susan L; Welte, Michael A

    2010-06-23

    A major strategy for purifying and isolating different types of intracellular organelles is to separate them from each other based on differences in buoyant density. However, when cells are disrupted prior to centrifugation, proteins and organelles in this non-native environment often inappropriately stick to each other. Here we describe a method to separate organelles by density in intact, living Drosophila embryos. Early embryos before cellularization are harvested from population cages, and their outer egg shells are removed by treatment with 50% bleach. Embryos are then transferred to a small agar plate and inserted, posterior end first, into small vertical holes in the agar. The plates containing embedded embryos are centrifuged for 30 min at 3000 g. The agar supports the embryos and keeps them in a defined orientation. Afterwards, the embryos are dug out of the agar with a blunt needle. Centrifugation separates major organelles into distinct layers, a stratification easily visible by bright-field microscopy. A number of fluorescent markers are available to confirm successful stratification in living embryos. Proteins associated with certain organelles will be enriched in a particular layer, demonstrating colocalization. Individual layers can be recovered for biochemical analysis or transplantation into donor eggs. This technique is applicable for organelle separation in other large cells, including the eggs and oocytes of diverse species.

  3. MOST Observations of sigma Ori E: Challenging the Centrifugal Breakout Narrative

    CERN Document Server

    Townsend, R H D; Rowe, J F; Moffat, A F J; Matthews, J M; Bohlender, D; Neiner, C; Telting, J H; Guenther, D B; Kallinger, T; Kuschnig, R; Rucinski, S M; Sasselov, D; Weiss, W W

    2013-01-01

    We present results from three weeks' photometric monitoring of the magnetic helium-strong star sigma Ori E using the MOST microsatellite. The star's light curve is dominated by twice-per-rotation eclipse-like dimmings arising when magnetospheric clouds transit across and occult the stellar disk. However, no evidence is found for any abrupt centrifugal breakout of plasma from the magnetosphere, either in the residual flux or in the depths of the light minima. Motivated by this finding we compare the observationally inferred magnetospheric mass against that predicted by a breakout analysis. The large discrepancy between the values leads us to argue that centrifugal breakout does not play a significant role in establishing the magnetospheric mass budget of sigma Ori E.

  4. MOST OBSERVATIONS OF {sigma} Ori E: CHALLENGING THE CENTRIFUGAL BREAKOUT NARRATIVE

    Energy Technology Data Exchange (ETDEWEB)

    Townsend, R. H. D. [Department of Astronomy, University of Wisconsin-Madison, 2535 Sterling Hall, 475 N. Charter Street, Madison, WI 53706 (United States); Rivinius, Th. [ESO-European Organisation for Astronomical Research in the Southern Hemisphere, Casilla 19001, Santiago 19 (Chile); Rowe, J. F. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Moffat, A. F. J. [Department de physique, Universite de Montreal C.P. 6128, Succursale Centre-Ville, Montreal, QC H3C 3J7 (Canada); Matthews, J. M.; Kallinger, T.; Kuschnig, R. [Department of Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC V6T 1Z1 (Canada); Bohlender, D. [National Research Council of Canada, Herzberg Institue of Astrophysics, 5071 West Saanich Road, Victoria, BC V9E 2E7 (Canada); Neiner, C. [LESIA, UMR 8109 du CNRS, Observatoire de Paris, UPMC, Universite Paris Diderot, 5 place Jules Janssen, 92195 Meudon Cedex (France); Telting, J. H. [Nordic Optical Telescope, Apartado 474, 38700 Santa Cruze de La Palma (Spain); Guenther, D. B. [Department of Astronomy and Physics, St. Marys University, Halifax, NS B3H 3C3 (Canada); Rucinski, S. M. [Department of Astronomy and Astrophysics, University of Toronto, 50 St George Street, Toronto, ON M5S 3H4 (Canada); Sasselov, D. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Weiss, W. W., E-mail: townsend@astro.wisc.edu [Institute for Astronomy, University of Vienna, Tuerkenschanzstrasse 17, A-1180 Vienna (Austria)

    2013-05-20

    We present results from three weeks' photometric monitoring of the magnetic helium-strong star {sigma} Ori E using the Microvariability and Oscillations of Stars microsatellite. The star's light curve is dominated by twice-per-rotation eclipse-like dimmings arising when magnetospheric clouds transit across and occult the stellar disk. However, no evidence is found for any abrupt centrifugal breakout of plasma from the magnetosphere, either in the residual flux or in the depths of the light minima. Motivated by this finding we compare the observationally inferred magnetospheric mass against that predicted by a breakout analysis. The large discrepancy between the values leads us to argue that centrifugal breakout does not play a significant role in establishing the magnetospheric mass budget of {sigma} Ori E.

  5. [Hematologic and endocrinologic effects of pulsatile cardiopulmonary bypass using a centrifugal pump].

    Science.gov (United States)

    Komoda, T; Maeta, H; Imawaki, S; Shiraishi, Y; Tanaka, S

    1992-06-01

    The effects of pulsatile and nonpulsatile flow during cardiopulmonary bypass (CPB) with of centrifugal pump (Sarns) and membrane oxygenator, on blood cells, hemodynamics, and hormonal response were studied. In the pulsatile group (group P) in which pulsatile flow was generated by centrifugal pump and a 20 Fr arterial cannula was used, hemolysis and reduction of platelet count during CPB were more marked than in the nonpulsatile group (group NP), in which the same type of circuit was used. When the 20 Fr arterial cannula was replaced with a 24 Fr cannula (group Pc), the rate of hemolysis during CPB was significantly reduced compared with that in group P (p less than 0.05). The rate of rise in plasma free hemoglobin from 10 to 70 minutes CPB in group Pc was 15.0 mg/dl/hr, this value did not exceed that in either group NP or in group Pr, in which a roller pump rather than centrifugal pump was used to generate pulsatile flow. These findings show that pulsatile CPB with a centrifugal pump produces no deleterious hematologic effect in clinical use. The rise in the level of angiotensin II in group P was significantly smaller than that in group NP (p less than 0.05), and the rise in plasma renin activity and levels of angiotensin I, adrenalin and noradrenaline were smaller than those in group NP, although these differences were no significance. These findings indicate that the centrifugal pump generates pulsatile flow effectively, although not so effectively as to prevent the rise in peripheral vascular resistance. During CPB, there was no change in levels of thyroid hormones, including free T3, free T4 and reverse T3, in either pulsatile groups P and Pc or nonpulsatile group. TSH level in group Pc was significantly elevated in contrast with that in the nonpulsatile group (p less than 0.05), in which no change in TSH level was seen. It is suggested that pulsatile perfusion using a centrifugal pump might maintain sufficient hypothalamic-pituitary function to permit

  6. ELECTRO-HYDRAULIC SERVO SYSTEM IN THE CENTRIFUGE FIELD

    Institute of Scientific and Technical Information of China (English)

    Dong Longlei; Yan Guirong; Li Ronglin

    2004-01-01

    The mechanical characteristics of the electro-hydraulic servo system in the centrifuge field are analyzed.The hydraulic pressure law in the centrifuge field indicates the existence of the centrifuge hydraulic pressure.The mechanical characteristics of the slide-valve and the dual nozzle flapper valve are studied,and it is found that the centrifuge field can not only increase the driving force or moment of the function units,but also decrease the stability of the components.Finally by applying Gauss minimum constraint principle,the dynamic model of the electro-hydraulic vibrator in the centrifuge field is established,and the mechanical restriction of the system is also presented.The study will be helpful for the realization of the combined vibration and centrifuge test system.

  7. Rapid centrifugation assay standarization for dengue virus isolation

    OpenAIRE

    Palomino, Miryam; Escuela de Biología, facultad de Ciencias Naturales y Matemáticas, Universidad Nacional federico Villarreal. Lima, Perú. Biólogo.; Gutierrez, Victoria; Centro Nacional de Salud Pública, Instituto Nacional de Salud. Lima, Perú. Biólogo.; Salas, Ramses; Laboratorio de Biotecnología, facultad de Ciencias Naturales y Matemáticas, Universidad Nacional federico Villarreal. Lima, Perú. Biólogo.

    2010-01-01

    The plate centrifugation assay was standardized for dengue virus isolation from serum samples. C6/36-HT cells were used determining the optimal values for centrifugation spin speed, inoculum, sera dilution, and incubation time. Then, 22 positive serum samples with viral isolation and viral strains of the four reference dengue virus serotypes were tested simultaneously by the standardized plate centrifugation method and the conventional tube culture. The isolations were typified by indirec...

  8. A curious spacetime entirely free of centrifugal acceleration

    CERN Document Server

    Dadhich, Naresh

    2012-01-01

    In the Einstein gravity, besides the usual gravitational and centrifugal potential there is an additional attractive term that couples these two together. It is fun to enquire whether the latter could fully counteract the centrifugal repulsion everywhere making the spacetime completely free of the centrifugal acceleration. We present here such a curious spacetime metric and it produces a global monopole like stresses going as $~1/r^2$ in an AdS spacetime.

  9. Fabrication of bulk metallic glasses by centrifugal casting method

    OpenAIRE

    R. Nowosielski; R. Babilas

    2007-01-01

    Purpose: The aim of the present work is characterization of the centrifugal casting method, apparatus andproduced amorphous materials, which are also known as bulk metallic glassesDesign/methodology/approach: The studied centrifugal casting system consists of two main parts: castingapparatus and injection system of molten alloy. The described centrifugal casting method was presented bypreparing a casting apparatus “CentriCast – 5”. The apparatus includes a cylindrical copper mold, which isrot...

  10. Rotational spectroscopy with an optical centrifuge

    CERN Document Server

    Korobenko, Aleksey; Hepburn, John W; Milner, Valery

    2013-01-01

    We demonstrate a new spectroscopic method for studying electronic transitions in molecules with extremely broad range of angular momentum. We employ an optical centrifuge to create narrow rotational wave packets in the ground electronic state of $^{16}$O$_2$. Using the technique of resonance-enhanced multi-photon ionization, we record the spectrum of multiple ro-vibrational transitions between $X^3\\Sigma_{g}^{-}$ and $C^3\\Pi_{g}$ electronic manifolds of oxygen. Direct control of rotational excitation, extending to rotational quantum numbers as high as $N\\gtrsim 120$, enables us to interpret the complex structure of rotational spectra of $C^3\\Pi_{g}$ beyond thermally accessible levels.

  11. Development of liquid nitrogen Centrifugal Pump

    Energy Technology Data Exchange (ETDEWEB)

    Abe, M; Sagiyama, R; Tsuchiya, H [Institute for Solid State Physics, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8581 (Japan); Takayama, T [Institute for Molecular Science, National Institutes of Natural Sciences, 38 Nishigo-Naka, Myodaiji, Okazaki, Aichi 444-8585 (Japan); Torii, Y [OMNIX, 1-15-3 Nishishinjuku, Shinjuku, Tokyo, 160-0023 (Japan); Nakamura, M [YN Nakamura Ltd, 3-9-25 Ohjima, Koto, Tokyo, 136-0072 (Japan); Hoshino, Y [JECC TORISHA Co. Ltd, 2-8-52 Yoshinodai, Kawagoe-shi, Saitama, 350-0833 (Japan); Odashima, Y [Department of Basic Sciences, University of Tokyo, 3-8-1 Komaba, Meguro, Tokyo 153-8902 (Japan)], E-mail: mirei@issp.u-tokyo.ac.jp

    2009-02-01

    Usually liquid nitrogen (LN{sub 2}) transfer from a container to a laboratory equipment takes place by applying pressure to the container to push out liquid or pouring liquid into the cryostat directly by lifting the container. In order to overcome inconvenience of pressuring or lifting containers, we have been developing the Liquid Nitrogen Centrifugal Pump of a small electric turbine pump. Significant advantages that both reducing time to fill LN{sub 2}and controlling the flow rate of liquid into the cryostat are obtained by introducing this pump. We have achieved the lift of about 800mm with the vessel's opening diameter of 28mm.

  12. DESIGN PARAMETERS OF CENTRIFUGAL COMPRESSOR INDUCER

    Directory of Open Access Journals (Sweden)

    Saim KOÇAK

    1998-03-01

    Full Text Available Design characteristics of centrifugal compressor impellers working with compressible fluids are analyzed, and the design parameters of inducer are defined. The effects of incidence, deviation and deflection angles, relative eddy, rotating stall and Mach number are investigated. The relation between minimum relative Mach number of inducer and flow angle is investigated and it is observed that the minimum Mach number occurs for flow angle values between -680 and -520 . In the design, the effect of a 100 difference in flow angle is found to be less than 1 % on minimum relative Mach number.

  13. Theory and experiments on centrifuge cratering

    Science.gov (United States)

    Schmidt, R. M.; Holsapple, K. A.

    1980-01-01

    Centrifuge experimental techniques provide possibilities for laboratory simulation of ground motion and cratering effects due to explosive loadings. The results of a similarity analysis for the thermomechanical response of a continuum show that increased gravity is a necessary condition for subscale testing when identical materials for both model and prototype are being used. The general similarity requirements for this type of subscale testing are examined both theoretically and experimentally. The similarity analysis is used to derive the necessary and sufficient requirements due to the general balance and jump equations and gives relations among all the scale factors for size, density, stress, body forces, internal energy, heat supply, heat conduction, heat of detonation, and time. Additional constraints due to specific choices of material constitutive equations are evaluated separately. The class of constitutive equations that add no further requirements is identified. For this class of materials, direct simulation of large-scale cratering events at small scale on the centrifuge is possible and independent of the actual constitutive equations. For a rate-independent soil it is shown that a small experiment at gravity g and energy E is similar to a large event at 1 G but with energy equal to g3E. Consequently, experiments at 500 G with 8 grams of explosives can be used to simulate a kiloton in the field. A series of centrifuge experiments was performed to validate the derived similarity requirements and to determine the practicality of applying the technique to dry granular soils having little or no cohesion. Ten shots using Ottawa sand at various gravities confirmed reproducibility of results in the centrifuge environment, provided information on particle size effects, and demonstrated the applicability of the derived similitude requirements. These experiments used 0.5-4 grams of pentaerythritol-tetranitrate (PETN) and 1.7 grams of lead-azide explosives. They

  14. Design and Prototyping of Micro Centrifugal Compressor

    Institute of Scientific and Technical Information of China (English)

    Shimpei Mizuki; Gaku Minorikawa; Toshiyuki Hirano; Yuichiro Asaga; Naoki Yamaguchi; Yutaka Ohta; Eisuke Outa

    2003-01-01

    In order to establish the design methodology of ultra micro centrifugal compressor, which is the most important component of ultra micro gas turbine unit, a 10 times of the final target size model was designed, prototyped and tested. The problems to be solved for downsizing were examined and 2-dimensional impeller was chosen as the first model due to its productivity. The conventional 1D prediction method, CFD and the inverse design were attempted. The prototyped compressor was driven by using a turbocharger and the performance characteristics were measured.

  15. Detection methods for centrifugal microfluidic platforms

    DEFF Research Database (Denmark)

    Burger, Robert; Amato, Letizia; Boisen, Anja

    2016-01-01

    Centrifugal microfluidics has attracted much interest from academia as well as industry, since it potentially offers solutions for affordable, user-friendly and portable biosensing. A wide range of so-called fluidic unit operations, e.g. mixing, metering, liquid routing, and particle separation......, have been developed and allow automation and integration of complex assay protocols in lab-on-a-disc systems. Besides liquid handling, the detection strategy for reading out the assay is crucial for developing a fully integrated system. In this review, we focus on biosensors and readout methods...

  16. Research on the development of the centrifugal spinning

    Directory of Open Access Journals (Sweden)

    Zhang Zhiming

    2017-01-01

    Full Text Available Centrifugal spinning is a new and efficient method to produce nanofibers quickly. It makes use of the centrifugal force instead of high voltage to produce the nanofibers. The centrifugal spinning has many advantages such as no high voltage, high yield, simple structure, no pollution and can be applied to high polymer material, ceramic and metal material. In order to have more understand about this novel nanofibers formation method, this paper introduces the method of centrifugal spinning and the effect of rotation speed, the properties of material such as viscosity and solvent evaporation, collector distance which have an impact on nanofibers morphology and diameter were also analyzed.

  17. Separative power of an optimised concurrent gas centrifuge

    Energy Technology Data Exchange (ETDEWEB)

    Bogovalov, Sergey; Boman, Vladimir [National Research Nuclear University (MEPHI), Moscow (Russian Federation)

    2016-06-15

    The problem of separation of isotopes in a concurrent gas centrifuge is solved analytically for an arbitrary binary mixture of isotopes. The separative power of the optimised concurrent gas centrifuges for the uranium isotopes equals to δU = 12.7 (V/700 m/s)2(300 K/T)(L/1 m) kg·SWU/yr, where L and V are the length and linear velocity of the rotor of the gas centrifuge and T is the temperature. This equation agrees well with the empirically determined separative power of optimised counter-current gas centrifuges.

  18. Computer simulation for centrifugal mold filling of precision titanium castings

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    Computer simulation codes were developed based on a proposed mathematical model for centrifugal mold filling processes and previous computer software for 3D mold filling and solidification of castings (CASM-3D for Windows). Sample simulations were implemented for mold filling processes of precision titanium castings under gravity and different centrifugal casting techniques. The computation results show that the alloy melt has a much stronger mold filling ability for thin section castings under a centrifugal force field than that only under the gravity. A "return back" mold filling manner is showed to be a reasonable technique for centrifugal casting processes, especially for thin section precision castings.

  19. Separative Power of an Optimised Concurrent Gas Centrifuge

    Directory of Open Access Journals (Sweden)

    Sergey Bogovalov

    2016-06-01

    Full Text Available The problem of separation of isotopes in a concurrent gas centrifuge is solved analytically for an arbitrary binary mixture of isotopes. The separative power of the optimised concurrent gas centrifuges for the uranium isotopes equals to δU = 12.7 (V/700 m/s2(300 K/T(L/1 m kg·SWU/yr, where L and V are the length and linear velocity of the rotor of the gas centrifuge and T is the temperature. This equation agrees well with the empirically determined separative power of optimised counter-current gas centrifuges.

  20. [Design and optimization of a centrifugal pump for CPCR].

    Science.gov (United States)

    Pei, J; Tan, X; Chen, K; Li, X

    2000-06-01

    Requirements for an optimal centrifugal pump, the vital component in the equipment for cardiopulmonary cerebral resuscitation(CPCR), have been presented. The performance of the Sarns centrifugal pump (Sarns, Inc./3M, Ann arbor, MI, U.S.A) was tested. The preliminarily optimized model for CPCR was designed according to the requirements of CPCR and to the comparison and analysis of several clinically available centrifugal pumps. The preliminary tests using the centrifugal pump made in our laboratory(Type CPCR-I) have confirmed the design and the optimization.

  1. Some aversive characteristics of centrifugally generated gravity.

    Science.gov (United States)

    Altman, F.

    1973-01-01

    The effective weight of rats was manipulated by centrifugation. Two effective weight levels were obtained. In three escape avoidance conditions a lever press produced a change from a base level of 2.1 g to a response level of 1.1 g. In a punishment condition a response produced a change from a 1.1 g level to a 2.1 g level and in an extinction condition responses had no effect on the 2.1 g effective weight level present. All changes took 30 sec and were maintained for an additional 10 sec before a return to base level was initiated. When responses occurred closer together than the 40 sec, they delayed the return to base level by 40 sec. This 40 sec interval is referred to as response-contingent-time. The response rate and amount of response-contingent-time served as the data. The results confirmed previous data that centrifugation is aversive. The results are interpreted as indicating that the aversiveness is attributable to the increase in effective weight, and that rats can discriminate the different angular velocity-radius of rotation combinations used.

  2. Solidification microstructure of centrifugally cast Inconel 625

    Directory of Open Access Journals (Sweden)

    Silvia Barella

    2017-07-01

    Full Text Available Centrifugal casting is a foundry process allowing the production of near net-shaped axially symmetrical components. The present study focuses on the microstructural characterization of centrifugally cast alloys featuring different chemical compositions for the construction of spheres applied in valves made of alloy IN625 for operation at high pressure. Control of the solidification microstructure is needed to assure the reliability of the castings. Actually, a Ni-base superalloy such as this one should have an outstanding combination of mechanical properties, high temperature stability and corrosion resistance. Alloys such as IN625 are characterised by a large amount of alloying elements and a wide solidification range, so they can be affected by micro-porosity defects, related to the shrinkage difference between the matrix and the secondary reinforcing phases (Nb-rich carbides and Laves phase. In this study, the microstructure characterization was performed as a function of the applied heat treatments and it was coupled with a calorimetric analysis in order to understand the mechanism ruling the formation of micro-porosities that can assure alloy soundness. The obtained results show that the presence of micro-porosities is governed by morphology and by the size of the secondary phases, and the presence of the observed secondary phases is detrimental to corrosion resistance.

  3. Postcardiotomy centrifugal assist: a single surgeon's experience.

    Science.gov (United States)

    Curtis, Jack J; McKenney-Knox, Charlotte A; Wagner-Mann, Colette C

    2002-11-01

    Because of the infrequent application of cardiac assist devices for postcardiotomy heart failure, most published reports include the results of learning curves from multiple surgeons. Between October 1986 and June 2001, a single surgeon used 35 Sarns Centrifugal Pumps as ventricular assist devices in 21 patients with severe hemodynamic compromise after open heart surgery (0.88% incidence). Patients' ages ranged from 39 to 77 (mean, 59.6 years). Three patients required right ventricular assist devices, 4 left ventricular assist devices, and 14 had biventricular assist devices. For all, the indication for application was inability to wean from cardiopulmonary bypass despite multiple inotropes and intraaortic balloon pumping. All were expected to be intraoperative deaths without further mechanical assistance. Patients were assisted from 2 to 434 h (median, 48 h). Fifteen patients (71.4%) were weaned from device(s), and 11 patients (52.4%) were hospital survivors. Actuarial survival in those dismissed from the hospital was 78% at 5 years and 39% at 10 years. Patients facing certain demise after cardiac surgery can be salvaged with temporary centrifugal mechanical assist. Results are competitive with that achieved with more sophisticated devices. Hospital survivors enjoy reasonable longevity.

  4. PARTICLE DISTRIBUTION IN CENTRIFUGAL ACCELERATING FIELDS

    Institute of Scientific and Technical Information of China (English)

    Yu Sirong; Zhang Xinping; He Zhenming; Liu Yaohui

    2003-01-01

    Based on continuum theory and moving law of particles, a model is presented to obtain gradient distribution of particles in centrifugal accelerating field, by which the particle distribution in gradient composite material can be predicted. The simulation shows with increases in rotating time, four regions gradually appear from the internal periphery to the external one, they are free region, transition region, steady region and surface reinforced region,and the latest three regions are defined as a rich region. Finally, the steady region disappears, and the rich region only includes transition region and surface reinforced region. The influences of centrifugal acceleration coefficient G,primary volume fraction (0,pouring temperature (p and density difference between the particle and the metal matrix on particles gradient distribution are studied in detail. The results of the theoretical analysis agree with experiment ones. Both of analysis and experiment results indicate that with the increase in G and (p, the particle distribution becomes more centralized and the consistence of particle in the surface periphery becomes larger.

  5. Design, Development and Analysis of Centrifugal Blower

    Science.gov (United States)

    Baloni, Beena Devendra; Channiwala, Salim Abbasbhai; Harsha, Sugnanam Naga Ramannath

    2017-05-01

    Centrifugal blowers are widely used turbomachines equipment in all kinds of modern and domestic life. Manufacturing of blowers seldom follow an optimum design solution for individual blower. Although centrifugal blowers are developed as highly efficient machines, design is still based on various empirical and semi empirical rules proposed by fan designers. There are different methodologies used to design the impeller and other components of blowers. The objective of present study is to study explicit design methodologies and tracing unified design to get better design point performance. This unified design methodology is based more on fundamental concepts and minimum assumptions. Parametric study is also carried out for the effect of design parameters on pressure ratio and their interdependency in the design. The code is developed based on a unified design using C programming. Numerical analysis is carried out to check the flow parameters inside the blower. Two blowers, one based on the present design and other on industrial design, are developed with a standard OEM blower manufacturing unit. A comparison of both designs is done based on experimental performance analysis as per IS standard. The results suggest better efficiency and more flow rate for the same pressure head in case of the present design compared with industrial one.

  6. High Efficiency Centrifugal Compressor for Rotorcraft Applications

    Science.gov (United States)

    Medic, Gorazd; Sharma, Om P.; Jongwook, Joo; Hardin, Larry W.; McCormick, Duane C.; Cousins, William T.; Lurie, Elizabeth A.; Shabbir, Aamir; Holley, Brian M.; Van Slooten, Paul R.

    2014-01-01

    The report "High Efficiency Centrifugal Compressor for Rotorcraft Applications" documents the work conducted at UTRC under the NRA Contract NNC08CB03C, with cost share 2/3 NASA, and 1/3 UTRC, that has been extended to 4.5 years. The purpose of this effort was to identify key technical barriers to advancing the state-of-the-art of small centrifugal compressor stages; to delineate the measurements required to provide insight into the flow physics of the technical barriers; to design, fabricate, install, and test a state-of-the-art research compressor that is representative of the rear stage of an axial-centrifugal aero-engine; and to acquire detailed aerodynamic performance and research quality data to clarify flow physics and to establish detailed data sets for future application. The design activity centered on meeting the goal set outlined in the NASA solicitation-the design target was to increase efficiency at higher work factor, while also reducing the maximum diameter of the stage. To fit within the existing Small Engine Components Test Facility at NASA Glenn Research Center (GRC) and to facilitate component re-use, certain key design parameters were fixed by UTRC, including impeller tip diameter, impeller rotational speed, and impeller inlet hub and shroud radii. This report describes the design effort of the High Efficiency Centrifugal Compressor stage (HECC) and delineation of measurements, fabrication of the compressor, and the initial tests that were performed. A new High-Efficiency Centrifugal Compressor stage with a very challenging reduction in radius ratio was successfully designed, fabricated and installed at GRC. The testing was successful, with no mechanical problems and the running clearances were achieved without impeller rubs. Overall, measured pressure ratio of 4.68, work factor of 0.81, and at design exit corrected flow rate of 3 lbm/s met the target requirements. Polytropic efficiency of 85.5 percent and stall margin of 7.5 percent were

  7. Microfluidic Adaptation of Density-Gradient Centrifugation for Isolation of Particles and Cells

    Directory of Open Access Journals (Sweden)

    Yuxi Sun

    2017-08-01

    Full Text Available Density-gradient centrifugation is a label-free approach that has been extensively used for cell separations. Though elegant, this process is time-consuming (>30 min, subjects cells to high levels of stress (>350 g and relies on user skill to enable fractionation of cells that layer as a narrow band between the density-gradient medium and platelet-rich plasma. We hypothesized that microfluidic adaptation of this technique could transform this process into a rapid fractionation approach where samples are separated in a continuous fashion while being exposed to lower levels of stress (<100 g for shorter durations of time (<3 min. To demonstrate proof-of-concept, we designed a microfluidic density-gradient centrifugation device and constructed a setup to introduce samples and medium like Ficoll in a continuous, pump-less fashion where cells and particles can be exposed to centrifugal force and separated via different outlets. Proof-of-concept studies using binary mixtures of low-density polystyrene beads (1.02 g/cm3 and high-density silicon dioxide beads (2.2 g/cm3 with Ficoll–Paque (1.06 g/cm3 show that separation is indeed feasible with >99% separation efficiency suggesting that this approach can be further adapted for separation of cells.

  8. Analysis of optimal design configurations for a multiple disk centrifugal blood pump.

    Science.gov (United States)

    Miller, G E; Fink, R

    1999-06-01

    A multiple disk centrifugal pump was analyzed as a blood pump for use in cardiac assistance or as a bridge to transplant device. The original configuration consisted of 6 parallel disks with 0.016 inch spacing between disks. This pump suffered from a degradation of flow with increasing afterload. A study was conducted to analyze flow performance as a function of afterload, preload, and motor speed. Configurations were examined including 4, 5, and 6 disks each with spacings of 0.15, 0.20, and 0.25 inches. Flow rates were examined for variations in afterload from 60-130 mm Hg, in preload from 0-20 mm Hg and for motor speeds of 1,250, 1,500, and 1,750 rpm. Analyses of afterload effects were intended to determine those configurations that produced less flow degradation with increasing afterload. Analyses of motor speed effects were intended to determine any configurations that produced greater flow increases with increasing motor speed. A hemolysis study was also performed. Both plasma free hemoglobin and the index of hemolysis were compared to data reported for other centrifugal blood flow devices. Results indicated that a 5 disk configuration with a 0.15 inch spacing produced optimal flow results with minimal degradation at higher afterloads. No optimal configuration based upon motor speed was indicated. Preload effects on pump performance were minimal. Hemolysis results indicated minimal blood damage with levels below those of many other centrifugal blood pump designs.

  9. Emission from the Centrifugal Magnetospheres of Magnetic B-type Stars

    Science.gov (United States)

    Shultz, M.; Wade, G.; Rivinius, T.; Townsend, R.; MiMeS Collaboration

    2016-11-01

    Approximately 10% of B-type stars possess strong magnetic fields, and of these, 25% host centrifugal magnetospheres in which the radiative wind, magnetic field, and rotational support interact to form a dense circumstellar plasma visible in a variety of diagnostic lines. In this article we review the basic theory behind CMs, outline current theoretical and observational problems, compare the observational properties of CM host stars to those of classical Be stars, and finally present preliminary results of a population study aimed at clarifying the characteristics of this growing sub-class.

  10. Emission from the Centrifugal Magnetospheres of Magnetic B-type Stars

    CERN Document Server

    Shultz, Matt; Rivinius, Thomas; Townsend, Richard

    2014-01-01

    Approximately 10% of B-type stars possess strong magnetic fields, and of these, 25% host centrifugal magnetospheres (CMs) in which the radiative wind, magnetic field, and rotational support interact to form a dense circumstellar plasma visible in a variety of diagnostic lines. In this article we review the basic theory behind CMs, outline current theoretical and observational problems, compare the observational properties of CM host stars to those of classical Be stars, and finally present preliminary results of a population study aimed at clarifying the characteristics of this growing sub-class.

  11. Separative power of an optimised concurrent gas centrifuge

    CERN Document Server

    Bogovalov, S V

    2015-01-01

    The problem of separation of uranium isotopes in a concurrent gas centrifuge is solved analytically. Separative power of the optimized concurrent gas centrifuges equals to $\\delta U=12.7(V/700~{\\rm m/s})^2 (300 ~{\\rm K}/T)L, ~{\\rm kg ~SWU/yr}$, where $L$ and $V$ are the length and linear velocity of the rotor of the gas centrifuge, $T$ is the temperature. This formula well agrees with an empirical separative power of counter current gas centrifuges. The optimal value of the separative power is not unique on the plane $(p_w,v_z)$, where $p_w$ is pressure at the wall of the rotor and $v_z$ is axial velocity of the gas. This value is constant on a line defined by the equation $p_wv_z=constant$. Equations defining the mass flux and the electric power necessary to support the rotation of the gas centrifuge are obtained.

  12. Numerical simulation of centrifugal casting of pipes

    Science.gov (United States)

    Kaschnitz, E.

    2012-07-01

    A numerical simulation model for the horizontal centrifugal pipe casting process was developed with the commercial simulation package Flow3D. It considers - additionally to mass, energy and momentum conservation equations and free surface tracking - the fast radial and slower horizontal movement of the mold. The iron inflow is not steady state but time dependent. Of special importance is the friction between the liquid and the mold in connection with the viscosity and turbulence of the iron. Experiments with the mold at controlled revolution speeds were carried out using a high-speed camera. From these experiments friction coefficients for the description of the interaction between mold and melt were obtained. With the simulation model, the influence of typical process parameters (e.g. melts inflow, mold movement, melt temperature, cooling media) on the wall thickness of the pipes can be studied. The comparison to results of pipes from production shows a good agreement between simulation and reality.

  13. Head pulsations in a centrifugal pump

    Science.gov (United States)

    Boiko, V. S.; Sotnyk, M. I.; Moskalenko, V. V.

    2017-08-01

    This article investigated the factors, which affect to the character of the head pulsations of a centrifugal pump. We investigated the dependence of the shape and depth of these pulsations from the operation mode of the pump. Was determined, that the head pulsations at the outlet of the impeller (pulsations on the blade passing frequency) cause head pulsations at the outlet of the pump, that have the same frequency, but differ in shape and depth. These pulsations depend on the design features of the flow-through part of the pump (from the ratio of hydraulic losses on the friction and losses on the vortex formation). A feature of the researches that were conducted is also the using of not only hydraulic but also electric modeling methods. It allows determining the values of the components of hydraulic losses.

  14. [Hemodynamic analysis of a centrifugal blood pump].

    Science.gov (United States)

    Wang, Yang; Yang, Ming; Xu, Zihao; Zhuang, Xiaoqi; Li, Qilei; Xu, Liang

    2015-01-01

    This paper built the mathematical model of a centrifugal blood pump, which was designed by ourselves, combined it with that of the human cardiovascular system and simulated the coupling system using Matlab. Then we set up the experiment platform, linked the blood pump to mock human cardiovascular system in case of three-stage heart failure, and measured aortic pressure and flow under different speed. The comparison between experiment results and simulation results not only indicates the coupling model is correct and the blood pump works well, but also shows that with the increase of blood pump speed, the pulsation of aortic pressure and flow will be reduced, this situation will affect the structure and function of blood vessels.

  15. A straight path centrifugal blood pump concept in the Capiox centrifugal pump.

    Science.gov (United States)

    Kijima, T; Oshiyama, H; Horiuchi, K; Nogawa, A; Hamasaki, H; Amano, N; Nojiri, C; Fukasawa, H; Akutsu, T

    1993-07-01

    This article describes comparative studies of a newly developed "straight path" centrifugal pump (Capiox centrifugal pump) targeted for open-heart surgery and circulatory support. A unique straight path design of the rotor was very effective in reducing the pump's rotational speed and prime volume. This pump was evaluated for hydraulics, hemolysis, depriming characteristics, cavitation, and heat generation. Two commercially available centrifugal pumps, the Biomedicus cone-type pump and the Sarns 3M impeller-type pump, were used as controls. The new pump required the lowest pump speed to produce the same flow rates under the same pressure loads and demonstrated the lowest hemolysis and the lowest temperature rise with the outlet clamped. The air volume required to deprime the new pump was one-third to one-half that for the other pumps, and no sign of cavitation was observed even if a small amount of air was introduced to the pump inlet under a negative pressure of 200 mm Hg.

  16. A Novel Fabrication Method for Functionally Graded Materials under Centrifugal Force: The Centrifugal Mixed-Powder Method

    Directory of Open Access Journals (Sweden)

    Eri Miura-Fujiwara

    2009-12-01

    Full Text Available One of the fabrication methods for functionally graded materials (FGMs is a centrifugal solid-particle method, which is an application of the centrifugal casting technique. However, it is the difficult to fabricate FGMs containing nano-particles by the centrifugal solid-particle method. Recently, we proposed a novel fabrication method, which we have named the centrifugal mixed-powder method, by which we can obtain FGMs containing nano-particles. Using this processing method, Cu-based FGMs containing SiC particles and Al-based FGMs containing TiO2 nano-particles on their surfaces have been fabricated. In this article, the microstructure and mechanical property of Cu/SiC and Al/TiO2 FGMs, fabricated by the centrifugal mixed-powder method are reviewed.

  17. The American Gas Centrifuge Past, Present, and Future

    Energy Technology Data Exchange (ETDEWEB)

    Waters, Dean

    2004-09-15

    The art of gas centrifugation was born in 1935 at the University of Virginia when Dr. Jesse Beams demonstrated experimentally the separation of chlorine isotopes using an ultra-high speed centrifuge. Dr. Beam’s experiment initiated work that created a rich history of scientific and engineering accomplishment in the United States in the art of isotope separation and even large scale biological separation by centrifugation. The early history of the gas centrifuge development was captured in a lecture and documented by Dr. Jesse Beams in 1975. Much of Dr. Beams lecture material is used in this paper up to the year 1960. Following work by Dr. Gernot Zippe at the University of Virginia between 1958 and 1960, the US government embarked on a centrifuge development program that ultimately led to the start of construction of the Gas Centrifuge Enrichment Plant in Piketon Ohio in the late 1970’s. The government program was abandoned in 1985 after investing in the construction of two of six planned process buildings, a complete supply chain for process and centrifuge parts, and the successful manufacture and brief operation of an initial complement of production machines that would have met 15 percent of the planned capacity of the constructed process buildings. A declining market for enriched uranium, a glut of uranium enrichment capacity worldwide, and the promise of a new laser based separation process factored in the decision to stop the government program. By the late 1990’s it had become evident that gas centrifugation held the best promise to produce enriched uranium at low cost. In1999, the United States Enrichment Corporation undertook an initiative to revive the best of the American centrifuge technology that had been abandoned fourteen years earlier. This is an exciting story and one that when complete will enable the United States to maintain its domestic supply and to be highly competitive in the world market for this important energy commodity. (auth)

  18. Centrifugal Spinning and Its Energy Storage Applications

    Science.gov (United States)

    Yao, Lu

    -/micro-fiber production method to substitute electrospinning in industrial production. Recently, centrifugal spinning has gained researchers' attention. The centrifugal spinning method avoids the use of high voltage supply and can work with concentrated solutions, and most importantly, it can increase the production rate of nano-/micro-fibers to at least two orders or magnitude higher than that of electrospinning. This novel fiber fabrication approach is mostly used in tissue engineering field, and it can be potentially applied in preparing electrodes for SIBs and EDLCs. In the present work, we firstly study the influence of solution intrinsic properties and operational parameters using polyacrylonitrile as an example, and establish the processing-structure relationships for this spinning technique. We then use this novel spinning method to prepare porous carbon nanofibers (PCNFs), SnO2 microfibers and lithium-substituted sodium layered transition metal oxide fibers and use them as electrodes for EDLCs and SIBs. The as-prepared PCNFs, SnO2 microfibers and lithiumsubstituted sodium layered transition metal oxide fibers exhibit good electrochemical performance. It is therefore demonstrated that centrifugal spinning can be a promising nano- /micro-fiber preparation approach for mass production of electrode materials used in energy storage applications.

  19. Separation of Nanoparticles in Aqueous Multiphase Systems through Centrifugation

    KAUST Repository

    Akbulut, Ozge

    2012-08-08

    This paper demonstrates the use of aqueous multiphase systems (MuPSs) as media for rate-zonal centrifugation to separate nanoparticles of different shapes and sizes. The properties of MuPSs do not change with time or during centrifugation; this stability facilitates sample collection after separation. A three-phase system demonstrates the separation of the reaction products (nanorods, nanospheres, and large particles) of a synthesis of gold nanorods, and enriches the nanorods from 48 to 99% in less than ten minutes using a benchtop centrifuge. © 2012 American Chemical Society.

  20. Plasma Mass Filters For Nuclear Waste Reprocessing

    Energy Technology Data Exchange (ETDEWEB)

    Fetterman, Abraham J. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Fisch, Nathaniel J. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)

    2011-05-01

    Practical disposal of nuclear waste requires high-throughput separation techniques. The most dangerous part of nuclear waste is the fission product, which contains the most active and mobile radioisotopes and produces most of the heat. We suggest that the fission products could be separated as a group from nuclear waste using plasma mass filters. Plasmabased processes are well suited to separating nuclear waste, because mass rather than chemical properties are used for separation. A single plasma stage can replace several stages of chemical separation, producing separate streams of bulk elements, fission products, and actinoids. The plasma mass filters may have lower cost and produce less auxiliary waste than chemical processing plants. Three rotating plasma configurations are considered that act as mass filters: the plasma centrifuge, the Ohkawa filter, and the asymmetric centrifugal trap.

  1. Plasma Mass Filters For Nuclear Waste Reprocessing

    Energy Technology Data Exchange (ETDEWEB)

    Abraham J. Fetterman and Nathaniel J. Fisch

    2011-05-26

    Practical disposal of nuclear waste requires high-throughput separation techniques. The most dangerous part of nuclear waste is the fission product, which contains the most active and mobile radioisotopes and produces most of the heat. We suggest that the fission products could be separated as a group from nuclear waste using plasma mass filters. Plasmabased processes are well suited to separating nuclear waste, because mass rather than chemical properties are used for separation. A single plasma stage can replace several stages of chemical separation, producing separate streams of bulk elements, fission products, and actinoids. The plasma mass filters may have lower cost and produce less auxiliary waste than chemical processing plants. Three rotating plasma configurations are considered that act as mass filters: the plasma centrifuge, the Ohkawa filter, and the asymmetric centrifugal trap.

  2. Saturn's Auroral Response to the Solar Wind: Centrifugal Instability Model

    Science.gov (United States)

    Sittler, Edward C.; Blanc, Michel F.; Richardson, J. D.

    2008-01-01

    We describe a model initially presented by Sittler et al. [2006] which attempts to explain the global response of Saturn's magnetosphere and its corresponding auroral behavior to variations in the solar wind. The model was derived from published simultaneous Hubble Space Telescope (HST) auroral images and Cassini upstream measurements taken during the month of January 2004. These observations show a direct correlation between solar wind dynamic pressure and (1) auroral brightening toward dawn local time, (2) an increase of rotational movement of auroral features to as much as 75% of the corotation speed, (3) the movement of the auroral oval to higher latitudes and (4) an increase in the intensity of Saturn Kilometric Radiation (SKR). This model is an alternative to the reconnection model of Cowley et al. [2004a,b; 2005] which is more Earth-like while ours stresses rotation. If angular momentum is conserved in a global sense, then when compressed the magnetosphere will tend to spin up and when it expands will tend to spin down. With the plasma sheet outer boundary at L approximates 15 we argue this region to be the dominant source region for the precipitating particles. If radial transport is dominated by centrifugal driven flux tube interchange motions, then when the magnetosphere spins up, outward transport will increase, the precipitating particles will move radially outward and cause the auroral oval to move to higher latitudes as observed. The Kelvin-Helmholtz instability may contribute to the enhanced emission along the dawn meridian as observed by HST. We present this model in the context of presently published observations by Cassini.

  3. Central centrifugal cicatricial alopecia: challenges and solutions.

    Science.gov (United States)

    Herskovitz, Ingrid; Miteva, Mariya

    2016-01-01

    Central centrifugal cicatricial alopecia (CCCA) is the most common scarring alopecia among African American women. Data about epidemiology, etiology, genetic inheritance, and management are scarce and come from individual reports or small series. CCCA has been associated with hot combing and traumatic hair styling for years; however, studies fail to confirm it as the sole etiologic factor. It has been shown in a small series that CCCA can be inherited in an autosomal dominant fashion, with a partial penetrance and a strong modifying effect of hairstyling and sex. CCCA presents clinically as a central area of progressive irreversible hair loss that expands to the periphery. A patchy form has also been described. Dermoscopy is helpful to identify the optimal site for the biopsy, which establishes the diagnosis. Well-designed randomized controlled trials are needed to discover the optimal management. At this point, patients are advised to avoid traction and chemical treatments; topical and intralesional steroids, calcineurin inhibitors, and minoxidil can be helpful in halting the progression.

  4. Central centrifugal cicatricial alopecia: challenges and solutions

    Directory of Open Access Journals (Sweden)

    Herskovitz I

    2016-08-01

    Full Text Available Ingrid Herskovitz, Mariya Miteva Department of Dermatology and Cutaneous Surgery, University of Miami L Miller School of Medicine, Miami, FL, USA Abstract: Central centrifugal cicatricial alopecia (CCCA is the most common scarring alopecia among African American women. Data about epidemiology, etiology, genetic inheritance, and management are scarce and come from individual reports or small series. CCCA has been associated with hot combing and traumatic hair styling for years; however, studies fail to confirm it as the sole etiologic factor. It has been shown in a small series that CCCA can be inherited in an autosomal dominant fashion, with a partial penetrance and a strong modifying effect of hairstyling and sex. CCCA presents clinically as a central area of progressive irreversible hair loss that expands to the periphery. A patchy form has also been described. Dermoscopy is helpful to identify the optimal site for the biopsy, which establishes the diagnosis. Well-designed randomized controlled trials are needed to discover the optimal management. At this point, patients are advised to avoid traction and chemical treatments; topical and intralesional steroids, calcineurin inhibitors, and minoxidil can be helpful in halting the progression. Keywords: hair loss, alopecia, dermatoscopy, dermoscopy, trichoscopy, black scalp, African American, scarring alopecia

  5. Centrifugal compressor tip clearance and impeller flow

    Energy Technology Data Exchange (ETDEWEB)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari [Laboratory of Fluid Dynamics, LUT School of Energy Systems, Lappeenranta University of Technology, Lappeenranta (Finland); Engeda, Abraham [Turbomachinery Laboratory, Dept. of Mechanical Engineering, Michigan State University, East Lansing (United States)

    2016-11-15

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease.

  6. Dermatoscopic features of central centrifugal cicatricial alopecia.

    Science.gov (United States)

    Miteva, Mariya; Tosti, Antonella

    2014-09-01

    No data exist on the dermatoscopic findings in central centrifugal cicatricial alopecia (CCCA). We sought to establish the spectrum of dermatoscopic features and their frequency in CCCA. We retrospectively evaluated 153 nonpolarized dermatoscopic images obtained from 51 women with histologically proven CCCA and established a list of 12 dermatoscopic features that were independently scored for each image. Controls included 30 dermatoscopic images from histologically proven cases of scarring traction alopecia and discoid lupus erythematosus. The receiver operating characteristic curve analysis assessed the specificity and sensitivity; Cohen kappa statistics assessed the agreement. Dermatoscopic pathologic correlations were performed on the horizontal sections of 41 of the 51 specimens, which were obtained with dermatoscopy-guided biopsy procedures. Peripilar white gray halo around the emergence of hairs was observed in 94% of patients and was highly specific and sensitive for CCCA in all clinical stages. It corresponds on pathology to the lamellar fibrosis surrounding the outer root sheath. This was a retrospective study. The presence of a peripilar white halo is a dermatoscopic feature that suggests the diagnosis of CCCA in African American patients with mild central thinning, and it is an optimal site from which to obtain a biopsy specimen. Copyright © 2014 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  7. Failure analysis of a polymer centrifugal impeller

    Directory of Open Access Journals (Sweden)

    Nikhil K. Kar

    2015-10-01

    Full Text Available A failure analysis investigation was performed on a fractured polymer impeller used in a respiratory blower. Light microscopy, scanning electron microscopy and finite element analysis techniques were utilized to characterize the mode(s of failure and fracture surfaces. A radial split down the impeller center was observed with symmetric fracture faces about the impeller bore. Fractographic analysis revealed brittle fracture features including Wallner lines, mirror, mist and hackle features stemming from the impeller bore, emanating radially outward. Crazed fibrils and faint fatigue striations suggest that intermittent load cycling led to initiation, and rapid propagation of multiple crack fronts originating along the impeller lip. Finite element analysis revealed a flexural condition induces localized stresses along the impeller lip. Significant wear features were also observed within the impeller bore, which may have contributed to premature failure of the impeller. The brittle fracture morphology and defects within the impeller bore suggest that premature failure occurred because of multiple interacting factors including: intermittently high centrifugal velocities, imbalance bore and shaft conditions, defects within the bore caused by machining, and stress concentrations along the circumference of the impeller lip.

  8. Centrifuging Step-Screw Conveyor for Regolith Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A variety of ISRU operations will utilize lunar regolith as feedstock. The proposed centrifuging step-screw conveyor concept will provide a well controlled robust,...

  9. Confusion around the tidal force and the centrifugal force

    CERN Document Server

    Matsuda, Takuya; Boffin, Henri M J

    2015-01-01

    We discuss the tidal force, whose notion is sometimes misunderstood in the public domain literature. We discuss the tidal force exerted by a secondary point mass on an extended primary body such as the Earth. The tidal force arises because the gravitational force exerted on the extended body by the secondary mass is not uniform across the primary. In the derivation of the tidal force, the non-uniformity of the gravity is essential, and inertial forces such as the centrifugal force are not needed. Nevertheless, it is often asserted that the tidal force can be explained by the centrifugal force. If we literally take into account the centrifugal force, it would mislead us. We therefore also discuss the proper treatment of the centrifugal force.

  10. Fluent-based numerical simulation of flow centrifugal fan

    Institute of Scientific and Technical Information of China (English)

    LI Xian-zhang

    2011-01-01

    Testing centrifugal fan flow field by physical laboratory is difficult because the testing system is complex and the workload is heavy, and the results observed by naked-eye deviates far from the actual value. To address this problem, the computational fluid dynamics software FLUENT was applied to establish three-dimensional model of the centrifugal fan. The numeral model was verified by comparing simulation data to experimental data. The pressure centrifugal fan and the speed changes in distribution in centrifugal fan was simulated by computational fluid dynamics software FLUENT. The simulation results show that the gas flow velocity in the impeller increases with impeller radius increase. Static pressure gradually increases when gas from the fan access is imported through fan impeller leaving fans.

  11. Manufacture of hollow ingots using centrifugal casting machines

    Science.gov (United States)

    Pomeshchikov, A. G.; Greneva, T. S.; Baidachenko, V. I.; Berezin, V. I.

    2010-12-01

    Centrifugal machines are proposed for the foundry created at the Almalyk Mining and Smelting Factory in order to produce hollow ingots of a liquid metal made by remelting of consumable electrodes in a refractory accumulating crucible.

  12. DESIGN AND FABRICATION OF A CENTRIFUGAL CASTING MACHINE

    Directory of Open Access Journals (Sweden)

    Adedipe Oyewole

    2011-12-01

    Full Text Available The design and fabrication of a centrifugal casting machine was successfully carried out. The operation of the machine was based on the principle of centrifugal force. Suitable design theory, analysis and calculation were adopted carried out in the course of the work. The mold is bolted to the base plate which can rotate at moderatespeeds thereby forcing the molten metal against the inner walls of the mold. This machine could be used to cast small engineering components. The centrifugal force on the machine was determined to be 3207.3N, while the required power on the machine was 854.7W. A test was carried out on the fabricated centrifugal casting machine with aluminum alloy and the machine was able to cast 6kg of aluminum alloy and the casting was successful.

  13. DEM simulation of granular flows in a centrifugal acceleration field

    Science.gov (United States)

    Cabrera, Miguel Angel; Peng, Chong; Wu, Wei

    2017-04-01

    The main purpose of mass-flow experimental models is abstracting distinctive features of natural granular flows, and allow its systematic study in the laboratory. In this process, particle size, space, time, and stress scales must be considered for the proper representation of specific phenomena [5]. One of the most challenging tasks in small scale models, is matching the range of stresses and strains among the particle and fluid media observed in a field event. Centrifuge modelling offers an alternative to upscale all gravity-driven processes, and it has been recently employed in the simulation of granular flows [1, 2, 3, 6, 7]. Centrifuge scaling principles are presented in Ref. [4], collecting a wide spectrum of static and dynamic models. However, for the case of kinematic processes, the non-uniformity of the centrifugal acceleration field plays a major role (i.e., Coriolis and inertial effects). In this work, we discuss a general formulation for the centrifugal acceleration field, implemented in a discrete element model framework (DEM), and validated with centrifuge experimental results. Conventional DEM simulations relate the volumetric forces as a function of the gravitational force Gp = mpg. However, in the local coordinate system of a rotating centrifuge model, the cylindrical centrifugal acceleration field needs to be included. In this rotating system, the centrifugal acceleration of a particle depends on the rotating speed of the centrifuge, as well as the position and speed of the particle in the rotating model. Therefore, we obtain the formulation of centrifugal acceleration field by coordinate transformation. The numerical model is validated with a series of centrifuge experiments of monodispersed glass beads, flowing down an inclined plane at different acceleration levels and slope angles. Further discussion leads to the numerical parameterization necessary for simulating equivalent granular flows under an augmented acceleration field. The premise of

  14. MULTIOBJECT OPTIMIZATION OF A CENTRIFUGAL IMPELLER USING EVOLUTIONARY ALGORITHMS

    Institute of Scientific and Technical Information of China (English)

    Li Jun; Liu Lijun; Feng Zhenping

    2004-01-01

    Application of the multiobjective evolutionary algorithms to the aerodynamic optimization design of a centrifugal impeller is presented. The aerodynamic performance of a centrifugal impeller is evaluated by using the three-dimensional Navier-Stokes solutions. The typical centrifugal impeller is redesigned for maximization of the pressure rise and blade load and minimization of the rotational total pressure loss at the given flow conditions. The B閦ier curves are used to parameterize the three-dimensional impeller blade shape. The present method obtains many reasonable Pareto optimal designs that outperform the original centrifugal impeller. Detailed observation of the certain Pareto optimal design demonstrates the feasibility of the present multiobjective optimization method tool for turbomachinery design.

  15. Comparative analysis of discrete exosome fractions obtained by differential centrifugation

    DEFF Research Database (Denmark)

    Jeppesen, Dennis Kjølhede; Hvam, Michael L; Primdahl-Bengtson, Bjarke

    2014-01-01

    BACKGROUND: Cells release a mixture of extracellular vesicles, amongst these exosomes, that differ in size, density and composition. The standard isolation method for exosomes is centrifugation of fluid samples, typically at 100,000×g or above. Knowledge of the effect of discrete...... ultracentrifugation speeds on the purification from different cell types, however, is limited. METHODS: We examined the effect of applying differential centrifugation g-forces ranging from 33,000×g to 200,000×g on exosome yield and purity, using 2 unrelated human cell lines, embryonic kidney HEK293 cells and bladder...... of phenol red and cleared by 200,000×g overnight centrifugation. The centrifugation tube fill level impacted the sedimentation efficacy. Comparative analysis by NTA, protein quantification, and detection of exosomal and contamination markers identified differences in vesicle size, concentration...

  16. 21 CFR 862.2140 - Centrifugal chemistry analyzer for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Centrifugal chemistry analyzer for clinical use... Instruments § 862.2140 Centrifugal chemistry analyzer for clinical use. (a) Identification. A centrifugal chemistry analyzer for clinical use is an automatic device intended to centrifugally mix a sample and...

  17. Design and Characterization of a Centrifugal Compressor Surge Test Rig

    OpenAIRE

    2011-01-01

    A detailed description of a new centrifugal compressor surge test rig is presented. The objective of the design and development of the rig is to study the surge phenomenon in centrifugal compression systems and to investigate a novel method of surge control by active magnetic bearing servo actuation of the impeller axial tip clearance. In this paper, we focus on the design, initial setup, and testing of the rig. The latter two include the commissioning of the rig and the experimental characte...

  18. Parameter Study of Melt Spun Polypropylene Fibers by Centrifugal Spinning

    Science.gov (United States)

    2014-07-01

    synthesis of C/Fe3O4 composite nanofibers and their application for high performance lithium-ion batteries . J Power Sources. 2008;83:717–723. 2. Zhang...spinning process . Eur Polym J. 2013;49:3834–3845. 9 1 DEFENSE TECHNICAL (PDF) INFORMATION CTR DTIC OCA 2 DIRECTOR (PDF) US ARMY RESEARCH...composites, and energy harvesting to tissue engineering and drug delivery. Centrifugal spinning is a new technique that uses centrifugal forces to form

  19. Synthesis and Analytical Centrifugation of Magnetic Model Colloids

    OpenAIRE

    Luigjes, B.

    2012-01-01

    This thesis is a study of the preparation and thermodynamic properties of magnetic colloids. First, two types of magnetic model colloids are investigated: composite colloids and single-domain nanoparticles. Thermodynamics of magnetic colloids is studied using analytical centrifugation, including a specially adapted centrifuge for measuring heavy and strongly light absorbing colloids. Magnetic composite colloids can be prepared from thermodynamically stable Pickering emulsions of 3-methacrylox...

  20. Centrifugal microfluidic platforms: advanced unit operations and applications.

    Science.gov (United States)

    Strohmeier, O; Keller, M; Schwemmer, F; Zehnle, S; Mark, D; von Stetten, F; Zengerle, R; Paust, N

    2015-10-01

    Centrifugal microfluidics has evolved into a mature technology. Several major diagnostic companies either have products on the market or are currently evaluating centrifugal microfluidics for product development. The fields of application are widespread and include clinical chemistry, immunodiagnostics and protein analysis, cell handling, molecular diagnostics, as well as food, water, and soil analysis. Nevertheless, new fluidic functions and applications that expand the possibilities of centrifugal microfluidics are being introduced at a high pace. In this review, we first present an up-to-date comprehensive overview of centrifugal microfluidic unit operations. Then, we introduce the term "process chain" to review how these unit operations can be combined for the automation of laboratory workflows. Such aggregation of basic functionalities enables efficient fluidic design at a higher level of integration. Furthermore, we analyze how novel, ground-breaking unit operations may foster the integration of more complex applications. Among these are the storage of pneumatic energy to realize complex switching sequences or to pump liquids radially inward, as well as the complete pre-storage and release of reagents. In this context, centrifugal microfluidics provides major advantages over other microfluidic actuation principles: the pulse-free inertial liquid propulsion provided by centrifugal microfluidics allows for closed fluidic systems that are free of any interfaces to external pumps. Processed volumes are easily scalable from nanoliters to milliliters. Volume forces can be adjusted by rotation and thus, even for very small volumes, surface forces may easily be overcome in the centrifugal gravity field which enables the efficient separation of nanoliter volumes from channels, chambers or sensor matrixes as well as the removal of any disturbing bubbles. In summary, centrifugal microfluidics takes advantage of a comprehensive set of fluidic unit operations such as

  1. CALCULATION AND IMPROVEMENT OF DYNAMIC CHARACTERISTICS OF CENTRIFUGE

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The modeling of the rotor-support system of a typical centrifuge is discussed. The impedance matching method, cooperating with Riccati transfer matrix method and modal analysis method are adopted to calculate its dynamic characteristics. The influences of the main parts to the critical speeds are analyzed. Based on the analysis, a critical speed in the operating speed range is tuned successfully, and thus the dynamic characteristics of the centrifuge are much improved.

  2. Centrifugal Lithography: Self-Shaping of Polymer Microstructures Encapsulating Biopharmaceutics by Centrifuging Polymer Drops.

    Science.gov (United States)

    Yang, Huisuk; Kim, Suyong; Kang, Geonwoo; Lahiji, Shayan F; Jang, Mingyu; Kim, Young Mi; Kim, Jae-Myung; Cho, Sang-Nae; Jung, Hyungil

    2017-07-13

    Polymeric microstructures encapsulating biopharmaceutics must be fabricated in a controlled environment to preserve the biological activity. There is increasing demand for simple methods designed to preserve the biological activity by utilizing the natural properties of polymers. Here, the paper shows that centrifugal lithography (CL) can be used for the fabrication of such microstructures in a single centrifugation, by engineering the self-shaping properties of hyaluronic acid (HA). In this method, HA drops are self-shaped into hourglass-microstructures to produce two dissolving microneedles (DMN), which facilitate transdermal delivery via implantation on the skin. In addition, tuberculin purified protein derivatives are encapsulated into HA DMNs under refrigerated conditions (4 °C) during CL. Therefore, the tuberculin skin test (TST) with the DMNs indicates minimal damage, as opposed to the case of TST with traditional hypodermic needles. These findings on the fabrication of polymeric microstructures with biopharmaceutics may trigger the development of various biomedical devices and therapies. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Effects of dilution and centrifugation on the survival of spermatozoa and the structure of motile sperm cell subpopulations in refrigerated Catalonian donkey semen.

    Science.gov (United States)

    Miró, J; Taberner, E; Rivera, M; Peña, A; Medrano, A; Rigau, T; Peñalba, A

    2009-11-01

    The aim of this work was to study the effects of dilution and centrifugation (i.e., two methods of reducing the influence of the seminal plasma) on the survival of spermatozoa and the structure of motile sperm cell subpopulations in refrigerated Catalonian donkey (Equus asinus) semen. Fifty ejaculates from nine Catalonian jackasses were collected. Gel-free semen was diluted 1:1, 1:5 or 1:10 with Kenney extender. Another sample of semen was diluted 1:5, centrifuged, and then resuspended with Kenney extender until a final dilution of 25x10(6) sperm/ml was achieved (C). After 24 h, 48 h or 72 h of refrigerated storage at 5 degrees C, aliquots of these semen samples were incubated at 37 degrees C for 5 min. The percentage of viable sperm was determined by staining with eosin-nigrosin. The motility characteristics of the spermatozoa were examined using the CASA system (Microptic, Barcelona, Spain). At 24h, more surviving spermatozoa were seen in the more diluted and in the centrifuged semen samples (1:1 48.71%; 1:5 56.58%, 1:10 62.65%; C 72.40%). These differences were maintained at 48 h (1:1 34.31%, 1:5 40.56%, 1:10 48.52%, C 66.30%). After 72 h, only the C samples showed a survival rate of above 25%. The four known donkey motile sperm subpopulations were maintained by refrigeration. However, the percentage of motile sperms in each subpopulation changed with dilution. Only the centrifuged samples, and only at 24h, showed exactly the same motile sperm subpopulation proportions as recorded for fresh sperm. However, the 1:10 dilutions at 24 and 48 h, and the centrifuged semen at 48 h, showed few variations compared to fresh sperm. These results show that the elimination of seminal plasma increases the survival of spermatozoa and the maintenance of motility patterns. The initial sperm concentration had a significant (P<0.05) influence on centrifugation efficacy, but did not influence the number of spermatozoa damaged by centrifugation. In contrast, the percentage of live

  4. Fabrication of Al/Diamond Particles Functionally Graded Materials by Centrifugal Sintered-Casting Method

    Science.gov (United States)

    Watanabe, Yoshimi; Shibuya, Masafumi; Sato, Hisashi

    2013-03-01

    The continuous graded structure of functionally graded materials (FGMs) can be created under a centrifugal force. Centrifugal sintered-casting (CSC) method, proposed by the authors, is one of the fabrication methods of FGM under centrifugal force. This method is a combination of the centrifugal sintering method and centrifugal casting method. In this study, Al/diamond particle FGM was fabricated by the proposed method.

  5. Hypergravity effects on glide arc plasma

    NARCIS (Netherlands)

    Šperka, J.; Souček, P.; van Loon, J.J.W.A.; Dowson, A.; Schwarz, C.; Krause, J.; Kroesen, G.; Kudrle, V.

    2013-01-01

    The behaviour of a special type of electric discharge - the gliding arc plasma - has been investigated in hypergravity (1g-18g) using the Large Diameter Centrifuge (LDC) at ESA/ESTEC. The discharge voltage and current together with the videosignal from a fast camera have been recorded during the exp

  6. Sedimentation of a suspension in a centrifugal field.

    Science.gov (United States)

    Lueptow, R M; Hübler, W

    1991-11-01

    To model centrifugal sedimentation of biological suspensions, the time history of sedimentation of particles in a centrifugal field was considered for two geometries: a tube and a cylindrical container. The Kynch theory for batch gravitational settling in Cartesian coordinates based on mass conservation was extended to include a centrifugal sedimentation force, cylindrical coordinates, and the Hawksley-Vand hindered settling model. The resulting quasi-linear partial differential equation was solved by the method of characteristics. The combination of radial dependence of the sedimentation force and cylindrical geometry in the centrifugal case results in several differences in the time-position history diagram of the sedimentation process compared to the gravitational case. First, instead of a region of uniform concentration equal to the initial concentration, a region of concentration that is continuously decreasing with time results. Second, in the region of particle accumulation, curved constant concentration contours result instead of straight lines. Finally, a secondary shock that is dependent upon the initial concentration and the radius ratio of the rotating vessel appears in the centrifugal case. The time history of the concentration for a particle suspension with an initial concentration typical of blood is presented.

  7. Experience with the Sarns centrifugal pump in postcardiotomy ventricular failure.

    Science.gov (United States)

    Curtis, J J; Walls, J T; Schmaltz, R; Boley, T M; Nawarawong, W; Landreneau, R J

    1992-09-01

    The reported clinical use of the Sarns centrifugal pump (Sarns, Inc./3M, Ann Arbor, Mich.) as a cardiac assist device for postcardiotomy ventricular failure is limited. During a 25-month period ending November 1988, we used 40 Sarns centrifugal pumps as univentricular or biventricular cardiac assist devices in 27 patients who could not be weaned from cardiopulmonary bypass despite maximal pharmacologic and intraaortic balloon support. Eighteen men and nine women with a mean age of 60.4 years (28 to 83) required assistance. Left ventricular assist alone was used in 12 patients, right ventricular assist in 2, and biventricular assist in 13. The duration of assist ranged from 2 to 434 hours (median 45). Centrifugal assist was successful in weaning 100% of the patients. Ten of 27 patients (37%) improved hemodynamically, allowing removal of the device(s), and 5 of 27 (18.5%) survived hospitalization. Survival of patients requiring left ventricular assist only was 33.3% (4/12). Complications were common and included renal failure, hemorrhage, coagulopathy, ventricular arrhythmias, sepsis, cerebrovascular accident, and wound infection. During 3560 centrifugal pump hours, no pump thrombosis was observed. The Sarns centrifugal pump is an effective assist device when used to salvage patients who otherwise cannot be weaned from cardiopulmonary bypass. Statistical analysis of preoperative patient characteristics, operative risk factors, and postoperative complications failed to predict which patients would be weaned from cardiac assist or which would survive.

  8. Exosome enrichment of human serum using multiple cycles of centrifugation.

    Science.gov (United States)

    Kim, Jeongkwon; Tan, Zhijing; Lubman, David M

    2015-09-01

    In this work, we compared the use of repeated cycles of centrifugation at conventional speeds for enrichment of exosomes from human serum compared to the use of ultracentrifugation (UC). After removal of cells and cell debris, a speed of 110 000 × g or 40 000 × g was used for the UC or centrifugation enrichment process, respectively. The enriched exosomes were analyzed using the bicinchoninic acid assay, 1D gel separation, transmission electron microscopy, Western blotting, and high-resolution LC-MS/MS analysis. It was found that a five-cycle repetition of UC or centrifugation is necessary for successful removal of nonexosomal proteins in the enrichment of exosomes from human serum. More significantly, 5× centrifugation enrichment was found to provide similar or better performance than 5× UC enrichment in terms of enriched exosome protein amount, Western blot band intensity for detection of CD-63, and numbers of identified exosome-related proteins and cluster of differentiation (CD) proteins. A total of 478 proteins were identified in the LC-MS/MS analyses of exosome proteins obtained from 5× UCs and 5× centrifugations including many important CD membrane proteins. The presence of previously reported exosome-related proteins including key exosome protein markers demonstrates the utility of this method for analysis of proteins in human serum.

  9. Subchronic use of the St. Jude centrifugal pump as a mechanical assist device in calves.

    Science.gov (United States)

    Curtis, J; Wagner-Mann, C; Mann, F; Demmy, T; Walls, J; Turk, J

    1996-06-01

    The purpose of this experiment was to study the effects of the St. Jude Lifestream centrifugal pump on hemodynamic and hematologic parameters and the incidence of postmortem findings in a subchronic ex vivo left ventricular assist animal model. Five calves were implanted with the pump as a left ventricular assist device (left atrial to thoracic aorta bypass) and studied for 96 h of continuous pumping under identical conditions. Heparin (100 IU/kg) was administered only in the initial saline pump prime. Throughout the protocol, mean arterial and central venous pressures averaged 102.1 +/- 4.6 and 3.4 +/- 2.2 mm Hg, respectively. Pump flow was 47.8 +/- 8.4 ml/kg/min at a mean pump speed of 1,676.3 +/- 106.1 rpm. No clinical abnormalities or mechanical malfunctions attributable to the pump were detected during the 96 h of continuous pumping for each calf. Mean plasma-free hemoglobin after 96 h was 3.9 +/- 3.7 mumol/L (p = 0.337 compared to baseline). At post mortem, renal infarctions were detected in 1 calf. No other pump-associated lesions were detected in any of the other calves. We have concluded that the St. Jude Lifestream centrifugal pump functions reliably during 96 h of continuous left heart bypass in a calf model.

  10. Centrifuge Techniques and Apparatus for Transport Experiments in Porous Media

    Energy Technology Data Exchange (ETDEWEB)

    Earl D. Mattson; Carl D. Paler; Robert W. Smith; Markus Flury

    2010-06-01

    This paper describes experimental approaches and apparatus that we have developed to study solute and colloid transport in porous media using Idaho National Laboratory's 2-m radius centrifuge. The ex-perimental techniques include water flux scaling with applied acceleration at the top of the column and sub-atmospheric pressure control at the column base, automation of data collection, and remote experimental con-trol over the internet. These apparatus include a constant displacement piston pump, a custom designed liquid fraction collector based on switching valve technology, and modified moisture monitoring equipment. Suc-cessful development of these experimental techniques and equipment is illustrated through application to transport of a conservative tracer through unsaturated sand column, with centrifugal acceleration up to 40 gs. Development of such experimental equipment that can withstand high accelerations enhances the centrifuge technique to conduct highly controlled unsaturated solute/colloid transport experiments and allows in-flight liquid sample collection of the effluent.

  11. Passively Shunted Piezoelectric Damping of Centrifugally-Loaded Plates

    Science.gov (United States)

    Duffy, Kirsten P.; Provenza, Andrew J.; Trudell, Jeffrey J.; Min, James B.

    2009-01-01

    Researchers at NASA Glenn Research Center have been investigating shunted piezoelectric circuits as potential damping treatments for turbomachinery rotor blades. This effort seeks to determine the effects of centrifugal loading on passively-shunted piezoelectric - damped plates. Passive shunt circuit parameters are optimized for the plate's third bending mode. Tests are performed both non-spinning and in the Dynamic Spin Facility to verify the analysis, and to determine the effectiveness of the damping under centrifugal loading. Results show that a resistive shunt circuit will reduce resonant vibration for this configuration. However, a tuned shunt circuit will be required to achieve the desired damping level. The analysis and testing address several issues with passive shunt circuit implementation in a rotating system, including piezoelectric material integrity under centrifugal loading, shunt circuit implementation, and tip mode damping.

  12. Studies on preparation of aceclofenac pellets by centrifugal granulator

    Directory of Open Access Journals (Sweden)

    Zibin GAO

    Full Text Available To prepare aceclofenac pellets by centrifugal granulation. Using 90~100 g of starch pellets as the core pellets,100 g of aceclofenac mixed with 50 g of microcrystalline cellulose(MCC and 4 g talc, methyl cellulose (HPMC as binder,the aceclofenac pellets were prepared by centrifugal granulation .And evaluate the quality of the pellets. The aceclofenac pellets had high yield and less losses,the pellets had a partical size of 0.70~0.88 mm(18~24 mesh)and had uniform particle size .the moisture ,drug content and dissolution meet the requirement . Aceclofenac pellets were prepared by the process of centrifugal granulation .The preparation prescription and process parameters were optimized by single factor method .and the pellets meet the standard requirements.

  13. Centrifuge modeling of shallow foundation on soft soil

    Energy Technology Data Exchange (ETDEWEB)

    Leung, P.K.; Ku, H.Y.; Pane, V.; Schiffman, R.L.

    1984-05-01

    A series of centrifuge model tests was performed to study the behavior of shallow foundations on soft normally consolidated clay. The model tests included testing of foundation models with one-dimensional, plane strain, and axially symmetric geometries. The nonlinear consolidation properties of the soil were determined using specially developed laboratory testing techniques. The centrifuge test data were then compared with conventional and finite strain theories for consolidation assessment, as well as a limit analysis solution for foundation stability considerations. It is found that centrifuge testing coupled with careful laboratory testing provides a useful tool to validate analytical procedures. It has demonstrated that the finite strain theory and the limit analysis solution are valid procedures for the determination of consolidation settlement and foundation penetration of shallow foundations on soft soil, respectively.

  14. Investigation of Surge Behavior in a Micro Centrifugal Compressor

    Institute of Scientific and Technical Information of China (English)

    Shimpei MIZUKI; Yuichiro ASAGA; Yushi ONO; Hoshio TSUJITA

    2006-01-01

    This paper reports the experimental and theoretical study of the surge occurred in prototyping an ultra micro centrifugal compressor. As the first step, the 10 times size model of an ultra micro centrifugal compressor having the 40 mm outer diameter was designed and manufactured. The detailed experimental investigations for the transient behavior of surge with several different values of B parameter were carried out. The experimental results during the surge were compared with those obtained by the non-linear lumped parameter theory in order to validate the effectiveness of the theoretical surge model for the micro centrifugal compressor. As a result, the quite different behavior of the surge appeared for the different values of B both in the experiment and in the analysis.

  15. Centrifuge modelling of drained lateral pile - soil response

    DEFF Research Database (Denmark)

    Klinkvort, Rasmus Tofte

    of rigid piles. The tests have been performed in homogeneously dense dry or saturated Fontainebleau sand in order to mimic simplified drained offshore soil conditions. Approximately half of the tests have been carried out to investigate the centrifuge procedure in order to create a methodology of testing...... for monopiles today. Therefore it appears that the methodology for monopiles lacks scientific justification and a better understanding of rigid piles is needed. More than 70 centrifuge tests on laterally loaded rigid model piles have been carried out in connection with this thesis to get a better understanding...... that enables the transformation of result from tests in model scale to prototype scale. The grain size to pile diameter ratio, the non-linear stress distribution and the pile installation was identified from this investigation as important parameters in reliable scaling of centrifuge results. The remaining...

  16. Centrifugal intensity and duration as countermeasures to soleus muscle atrophy

    Science.gov (United States)

    D'Aunno, Dominick S.; Thomason, Donald B.; Booth, Frank W.

    1990-01-01

    The effects of artificially induced gravity on the atrophy process of slow-twitch soleus muscle are studied in order to determine whether centrifugation could be an effective countermeasure to nonweight bearing at 1 G. It is observed that the soleus muscle atrophied 32 percent during seven days of nonweight bearing without countermeasures, and centrifugation treatment did not completely prevent atrophy relative to precontrol wet weight of the soleus muscle. Nonweight-bearing groups receiving treatments of 1, 1.5, or 2.6 G had 48, 56, and 65 percent, respectively, of the atrophy observed in a nonweight-bearing-only group compared with the precontrol group. It is concluded that, as a countermeasure to nonweight-bearing-induced atrophy of the soleus muscle, centrifugation at 2.6 G is no more effective than exposure to 1 or 1.5 G.

  17. Numerical Investigations of Slip Phenomena in Centrifugal Compressor Impellers

    Science.gov (United States)

    Huang, Jeng-Min; Luo, Kai-Wei; Chen, Ching-Fu; Chiang, Chung-Ping; Wu, Teng-Yuan; Chen, Chun-Han

    2013-03-01

    This study systematically investigates the slip phenomena in the centrifugal air compressor impellers by CFD. Eight impeller blades for different specific speeds, wrap angles and exit blade angles are designed by compressor design software to analyze their flow fields. Except for the above three variables, flow rate and number of blades are the other two. Results show that the deviation angle decreases as the flow rate increases. The specific speed is not an important parameter regarding deviation angle or slip factor for general centrifugal compressor impellers. The slip onset position is closely related to the position of the peak value in the blade loading factor distribution. When no recirculation flow is present at the shroud, the variations of slip factor under various flow rates are mainly determined by difference between maximum blade angle and exit blade angle, Δβmax-2. The solidity should be of little importance to slip factor correlations in centrifugal compressor impellers.

  18. Centrifugally activated bearing for high-speed rotating machinery

    Science.gov (United States)

    Post, Richard F.

    1994-01-01

    A centrifugally activated bearing is disclosed. The bearing includes an annular member that extends laterally and radially from a central axis. A rotating member that rotates about the central axis relative to the annular member is also included. The rotating member has an interior chamber that surrounds the central axis and in which the annular member is suspended. Furthermore, the interior chamber has a concave shape for retaining a lubricant therein while the rotating member is at rest and for retaining a lubricant therein while the rotating member is rotating. The concave shape is such that while the rotating member is rotating a centrifugal force causes a lubricant to be forced away from the central axis to form a cylindrical surface having an axis collinear with the central axis. This centrifugally displaced lubricant provides restoring forces to counteract lateral displacement during operation.

  19. Selective trapping of hydrogen plasma in mirror machine

    Science.gov (United States)

    Be'Ery, Ilan; Seemann, Omri; Fruchtman, Amnon; Fisher, Amnon; Ron, Amiram

    2013-10-01

    When ablation plasma, consisting mostly of hydrogen and carbon ions and neutral, is injected through the throat of a mirror machine, pure hydrogen plasma is observed to accumulate inside the mirror trap. In this work we study the formation of magnetized plasma beam, the scattering out of the loss cone, and the plasma decay in the mirror trap. The selective accumulation of hydrogen ions is shown to be a result of the difference in the magnetic channeling through a limiter and of difference in scattering probabilities into the trapped regions of phase space. The accumulation of plasma in the trap is limited by centrifugal drift instability, convecting plasma to the walls.

  20. Secondary Containment Design for a High Speed Centrifuge

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, K.W.

    1999-03-01

    Secondary containment for high speed rotating machinery, such as a centrifuge, is extremely important for operating personnel safety. Containment techniques can be very costly, ungainly and time consuming to construct. A novel containment concept is introduced which is fabricated out of modular sections of polycarbonate glazed into a Unistrut metal frame. A containment study for a high speed centrifuge is performed which includes the development of parameters for secondary containment design. The Unistrut/polycarbonate shield framing concept is presented including design details and proof testing procedures. The economical fabrication and modularity of the design indicates a usefulness for this shielding system in a wide variety of containment scenarios.

  1. Model Based Fault Detection in a Centrifugal Pump Application

    DEFF Research Database (Denmark)

    Kallesøe, Carsten; Cocquempot, Vincent; Izadi-Zamanabadi, Roozbeh

    2006-01-01

    A model based approach for fault detection in a centrifugal pump, driven by an induction motor, is proposed in this paper. The fault detection algorithm is derived using a combination of structural analysis, observer design and Analytical Redundancy Relation (ARR) design. Structural consideration...... is capable of detecting four different faults in the mechanical and hydraulic parts of the pump.......A model based approach for fault detection in a centrifugal pump, driven by an induction motor, is proposed in this paper. The fault detection algorithm is derived using a combination of structural analysis, observer design and Analytical Redundancy Relation (ARR) design. Structural considerations...

  2. Design Method for Channel Diffusers of Centrifugal Compressors

    Directory of Open Access Journals (Sweden)

    Mykola Kalinkevych

    2013-01-01

    Full Text Available The design method for channel diffusers of centrifugal compressors, which is based on the solving of the inverse problem of gas dynamics, is presented in the paper. The concept of the design is to provide high pressure recovery of the diffuser by assuming the preseparation condition of the boundary layer along one of the channel surfaces. The channel diffuser was designed with the use of developed method to replace the vaned diffuser of the centrifugal compressor model stage. The numerical simulation of the diffusers was implemented by means of CFD software. Obtained gas dynamic characteristics of the designed diffuser were compared to the base vaned diffuser of the compressor stage.

  3. Centripetal Acceleration and Centrifugal Force in General Relativity

    Science.gov (United States)

    Bini, D.; de Felice, F.; Jantzen, R. T.

    2003-05-01

    In nonrelativistic mechanics noninertial observers studying accelerated test particle motion experience a centripetal acceleration which, once interpreted as a centrifugal force acting on the particle, allows writing the particle's equation of motion in a Newtonian form, simply by adding the inertial force contribution to that of the external forces in the acceleration-equals-force equation. In general relativity centripetal and centrifugal acceleration generalizing the classical concepts must be properly (geometrically) defined. This requires a relative Frenet-Serret frame approach based on a family of test observers.

  4. Deep eutectic solvents in countercurrent and centrifugal partition chromatography.

    Science.gov (United States)

    Roehrer, Simon; Bezold, Franziska; García, Eva Marra; Minceva, Mirjana

    2016-02-19

    Deep eutectic solvents (DESs) were evaluated as solvents in centrifugal partition chromatography, a liquid-liquid chromatography separation technology. To this end, the partition coefficients of ten natural compounds of different hydrophobicity were determined in non-aqueous biphasic systems containing DES. The influence of the composition of DESs and the presence of water in the biphasic system on the partition coefficient were also examined. In addition, several process relevant physical properties of the biphasic system, such as the density and viscosity of the phases, were measured. A mixture of three to four hydrophobic compounds was successfully separated in a centrifugal partition extractor using a heptane/ethanol/DES biphasic system.

  5. Centrifuge modelling of a laterally cyclic loaded pile

    DEFF Research Database (Denmark)

    Klinkvort, Rasmus Tofte; Leth, Caspar Thrane; Hededal, Ole

    2010-01-01

    A total number of 9 static and 6 cyclic centrifuge tests on laterally loaded piles in very dense, dry sand was erformed. The prototype dimensions of the piles were 1 meter in diameter and penetration depths varying from 6 to 10 meters. The static tests were used to investigate the initial subgrade...... reaction modulus and as a reference for cyclic tests. For the cyclic tests the accumulation of deflections and the change in secant stiffness of the soil from repetitive loading were investigated. From all the tests carried out accumulations of deflections were seen. rom the centrifuge tests it was seen...

  6. Aspiration spiral-flow type centrifugal flotation machine

    Institute of Scientific and Technical Information of China (English)

    陈文义

    2002-01-01

    Aspiration spiral flow type centrifugal flotation machine takes full advantage of centrifugal force field and gravitational field, and strengthens flotation of coal slurry. As a new-type flotation machine of high efficiency, its key component is bubble generator. Which completes the process of ore pulp inflation and liberalization. The design, parameters and working principle of bubble generator provide the design of the same device in similar equipment with reference. The result of industrial operation shows that this machine is of such features as small occupational area, greater concentration ratio, high processing capacity, high efficiency and lower investment etc.

  7. Open-cycle centrifugal vapor-compression heat pump

    Science.gov (United States)

    Burgmeier, L. R.; Horner, J. E.

    1987-11-01

    The objectives of the program were: (1) to develop an open cycle, high lift, centrifugal steam compressor system that can be efficiently retrofitted to existing multi-effect and high temperature differential evaporators while maintaining the cost benefits of a single stage centrifugal compressor, and (2) to demonstrate the energy saving cost benefits of driving the compressor with a natural gas fueled gas turbine engine. The turbine exhaust was to be used for final drying of the product that was evaporated. The installation of the system is described along with the test activities through May 1987.

  8. Magnetron sputtering of copper on thermosensitive polymer materials of the gas centrifuge rotors

    Science.gov (United States)

    Borisevich, V.; Senchenkov, S.; Titov, D.

    2016-09-01

    Magnetron sputtering is the well-known and widely-used deposition technique for coating versatile high-quality and well-adhered films. However, the technology has some limitations, caused by high temperatures on the coating surface. The paper is devoted to the experimental development of a process of magnetron sputtering of copper on a surface coated with a thermosensitive polymer made of carbon fiber with epoxide binder. This process is applied for balancing a rotor of a gas centrifuge for isotope separation. The optimum operating parameters of the process are found and discussed. They were in quantitative agreement with data obtained by means of non-stationary modeling based on a global description of plasma in the typical geometry of the magnetron discharges obtained in independent research. The structure of the resulting layer is investigated.

  9. Mechanism of Gas Intrusion into Molten Metal during Horizontal Centrifugal Casting

    Institute of Scientific and Technical Information of China (English)

    NI Feng; ZHANG Xhan-ling; YANG Di-xin; BI Xiao-qin; ZHANG Yong-zhen

    2004-01-01

    A mechanism of gas intrusion into molten metal during horizontal centrifugal casting was introduced .Based upon this concept, a special pouring method was suggested ,which can effectively prevent the pinhole defects in horizontal centrifugal castings.

  10. Experimental investigation on centrifugal compressor blade crack classification using the squared envelope spectrum

    National Research Council Canada - National Science Library

    Li, Hongkun; Zhang, Xuefeng; Xu, Fujian

    2013-01-01

    Centrifugal compressors are a key piece of equipment for modern production. Among the components of the centrifugal compressor, the impeller is a pivotal part as it is used to transform kinetic energy into pressure energy...

  11. Centrifuge modeling of LNAPL transport in partially saturated sand

    NARCIS (Netherlands)

    Esposito, G.; Allersma, H.G.B.; Selvadurai, A.P.S.

    1999-01-01

    Model tests were performed at the Geotechnical Centrifuge Facility of Delft University of Technology, The Netherlands, to examine the mechanics of light nonaqueous phase liquid (LNAPL) movement in a partially saturated porous granular medium. The experiment simulated a 2D spill of LNAPL in an

  12. Ocular torsion before and after 1 hour centrifugation

    NARCIS (Netherlands)

    Groen, E.; Graaf, B. de; Bles, W.; Bos, J.E.

    1996-01-01

    To assess a possible otolith contribution to effects observed following prolonged expo-sure to hyper gravity, we used video-oculography to measure ocular torsion during static and dynamic conditions of lateral body tilt (roll) before and after one hour of centrifugation with a Gx-load of 3G. Static

  13. Centrifuge modelling of rigid piles in soft clay

    DEFF Research Database (Denmark)

    Klinkvort, R.T.; Poder, M.; Truong, P.

    2016-01-01

    of this study is to employ centrifuge modelling in order to derive experimental p-y curves for rigid piles embedded in over-consolidated soft clay. A kaolin clay sample was prepared and pre-consolidated by applying a constant pressure at the soil surface, while different over-consolidation ratios were achieved...

  14. Flow pattern in reverse-flow centrifugal separators

    NARCIS (Netherlands)

    Peng, W; Hoffmann, AC; Boot, PJAJ; Udding, A; Dries, HWA; Ekker, A; Kater, J

    2002-01-01

    Experimental flow patterns, determined by Laser Doppler Anemometry (LDA) for two types of reverse-flow centrifugal separators, are presented. The flow patterns in (a) a conventional cylinder-on-cone cyclone with tangential inlet and (b) a swirl tube with vane-generated swirl and a cylindrical body a

  15. Application of antioxidants and centrifugation for cryopreservation of boar spermatozoa.

    Science.gov (United States)

    Zhang, Wei; Yi, Kangle; Chen, Chao; Hou, Xiaofeng; Zhou, Xu

    2012-06-01

    Although cryopreserved boar semen has been available since 1975, a major breakthrough in commercial application has not yet occurred due to the high susceptibility of boar spermatozoa to damage during cryopreservation and the complicated process required for deep freezing. In recent years, the application of antioxidants during the cryopreservation of boar semen has been the subject of considerable research aimed at improving the quality of post-thaw semen. Centrifugation is necessary before using cryopreservation protocols for freezing boar spermatozoa. Studies of the effect of different centrifugation regimens on boar sperm recovery, yield and cryosurvival have made significant contributions. Therefore this review elucidates results of recent applications of various antioxidants and centrifugation regimens used in efforts to improve cryopreservation of boar spermatozoa. This review is intended to enhance understanding of the roles of these antioxidants and centrifugation regimens with respect to mechanisms that increase resistance to cryodamage of boar spermatozoa. In addition, the discussion addresses the need for developing an objective evaluation of effectiveness and estimating the prospect of application of new techniques for the cryopreservation of boar semen and its use in artificial insemination.

  16. Latex Micro-balloon Pumping in Centrifugal Microfluidic Platforms

    Science.gov (United States)

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Wadi harun, Sulaiman; Madou, Marc

    2014-01-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-stepped processes on a single microfluidics disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping designs have been developed to study the pump performance and capacity at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data shows that, the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon. PMID:24441792

  17. Centrifugally driven microfluidic disc for detection of chromosomal translocations

    DEFF Research Database (Denmark)

    Brøgger, Anna Line; Kwasny, Dorota; Bosco, Filippo G.

    2012-01-01

    and prognosis of patients. In this work we demonstrate a novel, centrifugally-driven microfluidic system for controlled manipulation of oligonucleotides and subsequent detection of chromosomal translocations. The device is fabricated in the form of a disc with capillary burst microvalves employed to control...

  18. Synthesis and Analytical Centrifugation of Magnetic Model Colloids

    NARCIS (Netherlands)

    Luigjes, B.

    2012-01-01

    This thesis is a study of the preparation and thermodynamic properties of magnetic colloids. First, two types of magnetic model colloids are investigated: composite colloids and single-domain nanoparticles. Thermodynamics of magnetic colloids is studied using analytical centrifugation, including a

  19. Numerical Simulation and Cold Modeling experiments on Centrifugal Casting

    Science.gov (United States)

    Keerthiprasad, Kestur Sadashivaiah; Murali, Mysore Seetharam; Mukunda, Pudukottah Gopaliengar; Majumdar, Sekhar

    2011-02-01

    In a centrifugal casting process, the fluid flow eventually determines the quality and characteristics of the final product. It is difficult to study the fluid behavior here because of the opaque nature of melt and mold. In the current investigation, numerical simulations of the flow field and visualization experiments on cold models have been carried out for a centrifugal casting system using horizontal molds and fluids of different viscosities to study the effect of different process variables on the flow pattern. The effects of the thickness of the cylindrical fluid annulus formed inside the mold and the effects of fluid viscosity, diameter, and rotational speed of the mold on the hollow fluid cylinder formation process have been investigated. The numerical simulation results are compared with corresponding data obtained from the cold modeling experiments. The influence of rotational speed in a real-life centrifugal casting system has also been studied using an aluminum-silicon alloy. Cylinders of different thicknesses are cast at different rotational speeds, and the flow patterns observed visually in the actual castings are found to be similar to those recorded in the corresponding cold modeling experiments. Reasonable agreement is observed between the results of numerical simulation and the results of cold modeling experiments with different fluids. The visualization study on the hollow cylinders produced in an actual centrifugal casting process also confirm the conclusions arrived at from the cold modeling experiments and numerical simulation in a qualitative sense.

  20. Synthesis and Analytical Centrifugation of Magnetic Model Colloids

    NARCIS (Netherlands)

    Luigjes, B.

    2012-01-01

    This thesis is a study of the preparation and thermodynamic properties of magnetic colloids. First, two types of magnetic model colloids are investigated: composite colloids and single-domain nanoparticles. Thermodynamics of magnetic colloids is studied using analytical centrifugation, including a s

  1. Design Optimization of Centrifugal Pump Using Radial Basis Function Metamodels

    Directory of Open Access Journals (Sweden)

    Yu Zhang

    2014-05-01

    Full Text Available Optimization design of centrifugal pump is a typical multiobjective optimization (MOO problem. This paper presents an MOO design of centrifugal pump with five decision variables and three objective functions, and a set of centrifugal pumps with various impeller shroud shapes are studied by CFD numerical simulations. The important performance indexes for centrifugal pump such as head, efficiency, and required net positive suction head (NPSHr are investigated, and the results indicate that the geometry shape of impeller shroud has strong effect on the pump's performance indexes. Based on these, radial basis function (RBF metamodels are constructed to approximate the functional relationship between the shape parameters of impeller shroud and the performance indexes of pump. To achieve the objectives of maximizing head and efficiency and minimizing NPSHr simultaneously, multiobjective evolutionary algorithm based on decomposition (MOEA/D is applied to solve the triobjective optimization problem, and a final design point is selected from the Pareto solution set by means of robust design. Compared with the values of prototype test and CFD simulation, the solution of the final design point exhibits a good consistency.

  2. Centrifugal Model Tests on Railway Embankments of Expansive Soils

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    Based on the centrifugal model tests on railway embankments of expansive soil in Nanning-Kunming railway,the author studied several embankments under different physical conditions. The stress and strain states and settlement of the embankments were analyzed, and the obtained results can be used as a reference to field construction.

  3. Liquid egg white pasteurization using a centrifugal UV irradiator

    Science.gov (United States)

    Studies are lacking on UV nonthermal pasteurization of liquid egg white (LEW). The objective of this study was to inactivate Escherichia coli using a UV irradiator that centrifugally formed a thin film of LEW on the inside of a rotating cylinder. The LEW was inoculated with E. coli K12 to approximat...

  4. Latex micro-balloon pumping in centrifugal microfluidic platforms.

    Science.gov (United States)

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Harun, Sulaiman Wadi; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Madou, Marc

    2014-03-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-step processes on a single microfluidic disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping mechanisms have been designed to study the pump performance at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data show that the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, a desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon.

  5. Vibratory centrifuge for the dewatering of coal sludge

    Energy Technology Data Exchange (ETDEWEB)

    Schiele, H.; Schlebusch, L.

    1981-03-03

    A vibratory centrifuge for the dewatering of coal sludge, washed small coal or slack which comprises a revolvable conical screen which has a diameter that increases towards its discharge end. The conical screen is vibratable in an axial direction and includes radial steps each having a height of at least 20 mm to rearrangement or loosen the material in the zone of each step.

  6. 14 CFR 35.35 - Centrifugal load tests.

    Science.gov (United States)

    2010-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: PROPELLERS Tests and Inspections § 35.35 Centrifugal load tests. The applicant must demonstrate that a propeller complies with paragraphs (a), (b) and (c) of this section without evidence of...

  7. The effect of balance holes to centrifugal pump performance

    Science.gov (United States)

    Babayigit, O.; Ozgoren, M.; Aksoy, M. H.; Kocaaslan, O.

    2017-07-01

    The aim of this study is to analyze of a centrifugal pump with and without balance holes by using ANSYS-Fluent software. The pump used in the study is a commercial centrifugal pump consisting of two stages that is a model of Sempa Pump Company. Firstly, models of impeller, diffuser, suction and discharge sections of the centrifugal pump were separately drawn using Ansys and Solidworks software. Later, grid structures were generated on the flow volume of the pump. Turbulent flow volume was numerically solved by realizable k-є turbulence model. The flow analyses were focused on the centrifugal pump performance and the flow characteristics under different operational conditions with/without balance holes. Distributions of flow characteristics such as velocity and pressure distributions in the flow volume were also determined, numerically. The results of Computational Fluid Dynamics (CFD) with/without balance holes for the pump head and hydraulic efficiency on the design flow rate of 80 m3/h were found to be 81.5/91.3 m and 51.9/65.3%, respectively.

  8. A contoured gap coaxial plasma gun with injected plasma armature

    Science.gov (United States)

    Witherspoon, F. Douglas; Case, Andrew; Messer, Sarah J.; Bomgardner, Richard; Phillips, Michael W.; Brockington, Samuel; Elton, Raymond

    2009-08-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 μg of plasma with density above 1017 cm-3 to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 μg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  9. A contoured gap coaxial plasma gun with injected plasma armature.

    Science.gov (United States)

    Witherspoon, F Douglas; Case, Andrew; Messer, Sarah J; Bomgardner, Richard; Phillips, Michael W; Brockington, Samuel; Elton, Raymond

    2009-08-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 microg of plasma with density above 10(17) cm(-3) to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 microg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  10. German chemical plants with particular reference to centrifuges

    Energy Technology Data Exchange (ETDEWEB)

    Broadbent, F.

    1946-01-01

    This report consisted of 9 reports. Report No. 1 was about Elmore Metall A. G., Schlandern on Siegburg. Two divisions of works in this factory were: (1) tube-drawing section for copper, steel, and zinc, with old machinery; (2) a section making electrolytically-deposited copper cylinders up to 100'' diameter, of high purity and excellent mechanical properties. The electrolytically-deposited copper cylinders were produced in lead-lined wooden tanks. Report No. 2 was about H. Krantz Maschinenfabrik, Aachen. This firm specialized in hydro-extractors, confined to types suitable for laundries and textile work. The machines built were of sizes from 800 mm to 1,8000 mm basket diameter. Report No. 3 was about O. Doerries A. G., Vorm Banning, and Seyfold Duren. This firm specialized in paper-making machinery, including centrifugal grit extractors for the treatment of paper stock. Erkensators number 4 and number 4L were compared in this report. Reports No. 4 and No. 5 were about I. G. Farbenindustrie, Dormagen, and Elberfeld. General information about the continuously-operating centrifuges was given. Report No. 6 was about Glanstoff Courtald between Cologne and Dormagen, where they used two methods of extracting water from viscose cakes, (1) by multiple-hinged candle hydro-extractors, and (2) by converted spinning pots. Report No. 7 was about Matthers and Weber, Duisberg, and gave general information about two kinds of centrifuges, (1) for crude bi-carbonate, and (2) for refined bi-carbonate. Report No. 8 was about Westfalia Separator A. G., Oelde; where the high-speed centrifuges of the ''cream separator'' or Laval type were made. Report No. 9 was about Escher Wyss, Ravensburg, where centrifuges, water turbines, spray dryers, and paper-making machinery were manufactured.

  11. Comparative analysis of discrete exosome fractions obtained by differential centrifugation

    Directory of Open Access Journals (Sweden)

    Dennis K. Jeppesen

    2014-11-01

    Full Text Available Background: Cells release a mixture of extracellular vesicles, amongst these exosomes, that differ in size, density and composition. The standard isolation method for exosomes is centrifugation of fluid samples, typically at 100,000×g or above. Knowledge of the effect of discrete ultracentrifugation speeds on the purification from different cell types, however, is limited. Methods: We examined the effect of applying differential centrifugation g-forces ranging from 33,000×g to 200,000×g on exosome yield and purity, using 2 unrelated human cell lines, embryonic kidney HEK293 cells and bladder carcinoma FL3 cells. The fractions were evaluated by nanoparticle tracking analysis (NTA, total protein quantification and immunoblotting for CD81, TSG101, syntenin, VDAC1 and calreticulin. Results: NTA revealed the lowest background particle count in Dulbecco's Modified Eagle's Medium media devoid of phenol red and cleared by 200,000×g overnight centrifugation. The centrifugation tube fill level impacted the sedimentation efficacy. Comparative analysis by NTA, protein quantification, and detection of exosomal and contamination markers identified differences in vesicle size, concentration and composition of the obtained fractions. In addition, HEK293 and FL3 vesicles displayed marked differences in sedimentation characteristics. Exosomes were pelleted already at 33,000×g, a g-force which also removed most contaminating microsomes. Optimal vesicle-to-protein yield was obtained at 67,000×g for HEK293 cells but 100,000×g for FL3 cells. Relative expression of exosomal markers (TSG101, CD81, syntenin suggested presence of exosome subpopulations with variable sedimentation characteristics. Conclusions: Specific g-force/k factor usage during differential centrifugation greatly influences the purity and yield of exosomes. The vesicle sedimentation profile differed between the 2 cell lines.

  12. 77 FR 65360 - Grant of Authority for Subzone Status (Centrifugal and Submersible Pumps); Auburn, NY

    Science.gov (United States)

    2012-10-26

    ... Foreign-Trade Zones Board Grant of Authority for Subzone Status (Centrifugal and Submersible Pumps... subzone at the centrifugal and submersible pump manufacturing and warehousing facilities of Xylem Water... activity related to the manufacturing of centrifugal and submersible pumps and related controllers at...

  13. 40 CFR Appendix - Alternative Organic HAP Emissions Limits for Open Molding, Centrifugal Casting, and SMC...

    Science.gov (United States)

    2010-07-01

    ... Limits for Open Molding, Centrifugal Casting, and SMC Manufacturing Operations Where the Standards Are..., Table 5 Alternative Organic HAP Emissions Limits for Open Molding, Centrifugal Casting, and SMC... casting—CR/HS 3,4 A vent system that moves heated air through the mold 27 lb/ton. 8. Centrifugal...

  14. 21 CFR 864.9275 - Blood bank centrifuge for in vitro diagnostic use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood bank centrifuge for in vitro diagnostic use... Manufacture Blood and Blood Products § 864.9275 Blood bank centrifuge for in vitro diagnostic use. (a) Identification. A blood bank centrifuge for in vitro diagnostic use is a device used only to separate blood...

  15. A novel technique using the Hendrickx centrifuge for extracting winter sporangia of Synchytrium endobioticum from soil

    NARCIS (Netherlands)

    Wander, J.G.N.; Berg, van den W.; Boogert, van den P.H.J.F.; Lamers, J.G.; Leeuwen, van G.C.M.; Hendrickx, G.; Bonants, P.J.M.

    2007-01-01

    A zonal centrifugation method, known as the Hendrickx centrifuge technique, was tested for routine detection of winter sporangia of Synchytrium endobioticum in soil. In four experiments the ability of the Hendrickx centrifuge to extract the sporangia from soil was compared with a method used by the

  16. Dense Plasma Injection Experiment at MCX

    Science.gov (United States)

    Uzun-Kaymak, I.; Messer, S.; Bomgardner, R.; Case, A.; Clary, R.; Ellis, R.; Elton, R.; Hassam, A.; Teodorescu, C.; Witherspoon, D.; Young, W.

    2009-09-01

    We present preliminary results of the High Density Plasma Injection Experiment at the Maryland Centrifugal Experiment (MCX). HyperV Technologies Corp. has designed, built, and installed a prototype coaxial gun to drive rotation in MCX. This gun has been designed to avoid the blow-by instability via a combination of electrode shaping and a tailored plasma armature. An array of diagnostics indicates the gun is capable of plasma jets with a mass of 160 μg at 70 km/s with an average plasma density above 1015 cm-3. Preliminary measurements are underway at MCX to understand the penetration of the plasma jet through the MCX magnetic field and the momentum transfer from the jet to the MCX plasma. Data will be presented for a wide range of MCX field parameters, and the prospects for future injection experiments will be evaluated.

  17. Radial plasma transport in Saturn's magnetosphere (Invited)

    Science.gov (United States)

    Hill, T. W.

    2010-12-01

    Radial plasma transport in the magnetosphere of Saturn, like that of Jupiter, is driven by the centrifugal force of (partial) corotation acting on internally generated plasma. A significant difference is that the internal plasma source is evidently broadly distributed throughout the inner magnetosphere of Saturn (4 CAPS and MAG), and reproduced in numerical simulations (RCM) that contain a distributed plasma source, although it has not, to my knowledge, been explained by an analytical theory containing an active plasma source. Both planets exhibit strong magnetospheric modulations near the planetary spin period, probably indicating a persistent longitudinal asymmetry of the radial plasma transport process. At Jupiter such an asymmetry is readily understood as a consequence of the dramatic asymmetry of the intrinsic planetary magnetic field. This is not so at Saturn, where any such field asymmetry is known to be very modest at best. In neither case has the precise nature of the asymmetry been identified either observationally or theoretically.

  18. Environmental and centrifugal factors influencing the visco-elastic properties of oral biofilms in vitro.

    Science.gov (United States)

    Peterson, Brandon W; Busscher, Henk J; Sharma, Prashant K; van der Mei, Henny C

    2012-01-01

    Centrifugal compaction causes changes in the surface properties of bacterial cells. It has been shown previously that the surface properties of planktonic cells change with increasing centrifugal compaction. This study aimed to analyze the influences of centrifugal compaction and environmental conditions on the visco-elastic properties of oral biofilms. Biofilms were grown out of a layer of initially adhering streptococci, actinomyces or a combination of these. Different uni-axial deformations were induced on the biofilms and the load relaxations were measured over time. Linear-Regression-Analysis demonstrated that both the centrifugation coefficient for streptococci and induced deformation influenced the percentage relaxation. Centrifugal compaction significantly influenced relaxation only upon compression of the outermost 20% of the biofilm (p centrifugal compaction of initially adhering, centrifuged bacteria extend to the visco-elastic properties of biofilms, indicating that the initial bacterial layer influences the structure of the entire biofilm.

  19. Centrifugal separation of liquid carbon dioxide from natural gas

    Directory of Open Access Journals (Sweden)

    Batalović Veselin B.

    2014-01-01

    Full Text Available Natural gas is becoming more and more a commodity in the global energy consumption. New technologies like the conversion from gas to liquid, contribute to this. But more than 16 % of the currently known global gas reserves cannot be produced due to severe CO2 and/or H2S contamination: (CO2 > 10% and H2S> 5%. The traditional technology of amine treatment is not able to economically remove these contaminants. The objective of this article is to investigate the possibilities of centrifugal separation to resolve the problem. After analyzing the existing situation, in the centrifugal separation of natural gas, some innovations in separators design and theory are suggested. The aim of the presented theoretical considerations is that the complex theory of separation to adapt to the needs of engineers engaged on the design, development and operation of these devices. [Projekat Ministarstva nauke Republike Srbije, br. 33001

  20. Massively parallel single-molecule manipulation using centrifugal force

    CERN Document Server

    Halvorsen, Ken

    2009-01-01

    Precise manipulation of single molecules has already led to remarkable insights in physics, chemistry, biology and medicine. However, widespread adoption of single-molecule techniques has been impeded by equipment cost and the laborious nature of making measurements one molecule at a time. We have solved these issues with a new approach: massively parallel single-molecule force measurements using centrifugal force. This approach is realized in a novel instrument that we call the Centrifuge Force Microscope (CFM), in which objects in an orbiting sample are subjected to a calibration-free, macroscopically uniform force-field while their micro-to-nanoscopic motions are observed. We demonstrate high-throughput single-molecule force spectroscopy with this technique by performing thousands of rupture experiments in parallel, characterizing force-dependent unbinding kinetics of an antibody-antigen pair in minutes rather than days. Additionally, we verify the force accuracy of the instrument by measuring the well-est...

  1. Considerations in designing a centrifugal atomiser for metal powder production

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Y.Y. [Department of Engineering, The University of Liverpool, Liverpool L69 3GH (United Kingdom)]. E-mail: y.y.zhao@livepool.ac.uk

    2006-07-01

    In centrifugal atomisation for metal powder production, the key to the control of the particle sizes is the design of the atomiser. This paper studies the main issues concerned in designing a centrifugal atomiser and provides guidance on the selection of an electric motor, radius of atomiser, slope angle of atomiser wall and flow rate of cooling water. In the selection of the atomiser radius, the power and material constraints as well as the hydraulic jump radius need to be considered. A cup atomiser with a slope angle of 60-70{sup o} would result in small spray droplets and thus a fine powder. The water cooling system needs to be assessed by examining the heat flow in the solid metal layer and in the atomiser.

  2. Production of centrifugal fields greater than 100 million times gravity.

    Science.gov (United States)

    Katano, R; Shimizu, S

    1979-07-01

    A high-speed rotation instrument to produce centrifugal fields greater than 100 million times gravity has been constructed. Small, solid, spherical high-carbon chromium steel rotors are suspended magnetically in high vacuum and spun by a rotating magnetic field. It is found that the spinning rotor explodes when the calculated average value of stress in the meridian plane reaches about 1.2 times the tensile strength of the material. The maximum speed of rotation so far achieved for more than a few days without bursting was obtained with a rotor of 1.50 mm diameter. The speed of 2.11 x 10(5) rev/s corresponded to a centrifugal field of 1.34 x 10(8) times gravity. Our instrument will find application in the study of nuclear atomic phenomena.

  3. Analysis of cantilever NEMS in centrifugal-fluidic systems

    Science.gov (United States)

    Mohsen-Nia, Mohsen; Abadian, Fateme; Abadian, Naeime; Dehkordi, Keivan Mosaiebi; Keivani, Maryam; Abadyan, Mohamadreza

    2016-07-01

    Electromechanical nanocantilevers are promising for using as sensors/detectors in centrifugal-fluidic systems. For this application, the presence of angular speed and electrolyte environment should be considered in the theoretical analysis. Herein, the pull-in instability of the nanocantilever incorporating the effects of angular velocity and liquid media is investigated using a size-dependent continuum theory. Using d’Alembert principle, the angular speed is transformed into an equivalent centrifugal force. The electrochemical and dispersion forces are incorporated considering the corrections due to the presence of electrolyte media. Two different approaches, i.e., the Rayleigh-Ritz method (RRM) and proposing a lumped parameter model (LPM), were applied to analyze the system. The models are validated with the results presented in literature. Impacts of the angular velocity, electrolyte media, dispersion forces, and size effect on the instability characteristics of the nanocantilever are discussed.

  4. Stage-efficiency of centrifugal extractor used in nuclear industry

    Institute of Scientific and Technical Information of China (English)

    吴秋林; 景山; 王兴海; 宋崇立

    2003-01-01

    The stage-efficiency of a single-stage prototype (d70) centrifugal extractor and the cascade is tested by HNO3-Nd3+ and 30%TRPO-kerosene system. The experimental results of the single-stage centrifugal extractor show that the carryover of the two phases decreases with increasing ratio of the two flow rate and rotation rate and the stage efficiency increases with not only decreasing total flow rate but also increasing rotor speed. However, the experimental results of the cascade show that the average stage efficiency of the cascade increases with not only decreasing total flow rate but also increasing rotor speed in both three-stage mode and two-stage mode.

  5. Centrifugal microfluidic platform for ultrasensitive detection of botulinum toxin.

    Science.gov (United States)

    Koh, Chung-Yan; Schaff, Ulrich Y; Piccini, Matthew E; Stanker, Larry H; Cheng, Luisa W; Ravichandran, Easwaran; Singh, Bal-Ram; Sommer, Greg J; Singh, Anup K

    2015-01-20

    We present an innovative centrifugal microfluidic immunoassay platform (SpinDx) to address the urgent biodefense and public health need for ultrasensitive point-of-care/incident detection of botulinum toxin. The simple, sample-to-answer centrifugal microfluidic immunoassay approach is based on binding of toxins to antibody-laden capture particles followed by sedimentation of the particles through a density-media in a microfluidic disk and quantification by laser-induced fluorescence. A blind, head-to-head comparison study of SpinDx versus the gold-standard mouse bioassay demonstrates 100-fold improvement in sensitivity (limit of detection = 0.09 pg/mL), while achieving total sample-to-answer time of capture beads and detection antibodies) are disconnected from the disk architecture and the reader, facilitating rapid development of new assays. SpinDx can also serve as a general-purpose immunoassay platform applicable to diagnosis of other conditions and diseases.

  6. Meteor Crater: Energy of formation - Implications of centrifuge scaling

    Science.gov (United States)

    Schmidt, R. M.

    1980-01-01

    Recent work on explosive cratering has demonstrated the utility of performing subscale experiments on a geotechnic centrifuge to develop scaling rules for very large energy events. The present investigation is concerned with an extension of this technique to impact cratering. Experiments have been performed using a projectile gun mounted directly on the centrifuge rotor to launch projectiles into a suitable soil container undergoing centripetal accelerations in excess of 500 G. The pump tube of a two-stage light-gas gun was used to attain impact velocities of approximately 2 km/sec. The results of the experiments indicate that the energy of formation of any large impact crater depends upon the impact velocity. This dependence, shown for the case of Meteor Crater, is consistent with analogous results for the specific energy dependence of explosives and is expected to persist to impact velocities in excess of 25 km/sec.

  7. Operation of Droplet-Microfluidic Devices with a Lab Centrifuge

    Directory of Open Access Journals (Sweden)

    Noorsher Ahmed

    2016-09-01

    Full Text Available Microfluidic devices are valuable for a variety of biotechnology applications, such as synthesizing biochemical libraries, screening enzymes, and analyzing single cells. However, normally, the devices are controlled using specialized pumps, which require expert knowledge to operate. Here, we demonstrate operation of poly(dimethylsiloxane devices without pumps. We build a scaffold that holds the device and reagents to be infused in a format that can be inserted into a 50 mL falcon tube and spun in a common lab centrifuge. By controlling the device design and centrifuge spin speed, we infuse the reagents at controlled flow rates. We demonstrate the encapsulation and culture of clonal colonies of red and green Escherichia coli in droplets seeded from single cells.

  8. Centrifuge modeling of PGD response of buried pipe

    Institute of Scientific and Technical Information of China (English)

    Michael O'Rourke; Vikram Gadicherla; Tarek Abdoun

    2005-01-01

    A new centrifuge based method for determining the response of continuous buried pipe to PGD is presented.The physical characteristics of the RPI's 100 g-ton geotechnical centrifuge and the current lifeline experiment split-box are described: The split-box contains the model pipeline and surrounding soil and is manufactured such that half can be offset, in flight, simulating PGD. In addition, governing similitude relations which allow one to determine the physical characteristics,(diameter, wall thickness and material modulus of elasticity) of the model pipeline are presented. Finally, recorded strains induced in two buried pipes with prototype diameters of 0.63 m and 0.95 m (24 and 36 inch) subject to 0.6 and 2.0 meters (2and 6 feet) of full scale fault offsets and presented and compared to corresponding FE results.

  9. The simulation and performance of a centrifugal chiller

    Science.gov (United States)

    Jackson, W. L.; Chen, F. C.; Hwang, B. C.

    A computer simulation model was developed to analyze the performance of a water-cooled centrifugal chiller. The model is based on a heat pump thermodynamic cycle and empirical correlations for the performance of the system components. The system simulated is composed of a variable-speed centrifugal compressor with a hot-gas bypass option for capacity control, two shell-and-tube heat exchangers, and an expansion device. The model was validated and calibrated against the experimental test results of a 125-ton chiller. The performance of a similar chiller system at various operating conditions and design modifications was analyzed. System performance comparisons were made between a baseline case, cases with high-performance heat exchanger tubes and compressor motor, and various variable-speed compressor operating strategies. It was found that significant performance improvement can be realized by using variable-speed drive and on-demand control strategy.

  10. Dynamical System Analysis of Unsteady Phenomena in Centrifugal Compressor

    Institute of Scientific and Technical Information of China (English)

    YasuyukiKomatsubara; ShimpeiMizuki

    1997-01-01

    Surge and rotating stall occurring in a centrifugal compressor system are investigated by using a phase portrait reconstruction method.From experimentally measured time series of data,the method clarified the cyclic behavior of surge.For rotating stall,there still remain problems in the phase portrait due to the chaotic behavior.However,the results obtained by the present method are able to provide new insights to the modelings for surge and rotating stall.Surge and roatting stall occurring in a centrifugal compressor system are investigated by using a phase portrait reconstruction method.From experimentally measured time series of data,the method clarified the cylcic behavior of surge.For rotating stall,there still remain problems in the phase portrait due to the chaotic behavior.However,the results obtained by the present method are able to provide new insights to the modelings for surge and rotating stall.

  11. Hemocompatibility of a hydrodynamic levitation centrifugal blood pump.

    Science.gov (United States)

    Yamane, Takashi; Maruyama, Osamu; Nishida, Masahiro; Kosaka, Ryo; Sugiyama, Daisuke; Miyamoto, Yusuke; Kawamura, Hiroshi; Kato, Takahisa; Sano, Takeshi; Okubo, Takeshi; Sankai, Yoshiyuki; Shigeta, Osamu; Tsutsui, Tatsuo

    2007-01-01

    A noncontact type centrifugal pump without any complicated control or sensing modules has been developed as a long-term implantable artificial heart. Centrifugal pumps with impellers levitated by original hydrodynamic bearings were designed and have been modified through numerical analyses and in vitro tests. The hemolysis level was reduced by changing the pressure distribution around the impeller and subsequently expanding the bearing gap. Thrombus formation in the bearing was examined with in vitro thrombogenesis tests and was reduced by changing the groove shapes to increase the bearing-gap flow to 3% of the external flow. Unnecessary vortices around the vanes were also eliminated by changing the number of vanes from four to six.

  12. Centrifugal stretching of 170Hf in the interacting boson model

    Directory of Open Access Journals (Sweden)

    Werner V.

    2014-03-01

    Full Text Available We present the results of a recent experiment to deduce lifetimes of members of the ground state rotational band of 170Hf, which show the effect of centrifugal stretching in this deformed isotope. Results are compared to the geometrical confined beta-soft(CBS rotor model, as well as to the interacting boson model (IBM. Two methods to correct for effects due to the finite valence space within the IBM are proposed.

  13. Centrifugal Blower for Personal Air Ventilation System (PAVS) - Phase 1

    Science.gov (United States)

    2015-02-01

    functionality. 15. SUBJECT TERMS COOLING SBIR REPORTS AXIAL FLOW FANS OFF THE SHELF EQUIPMENT BLOWERS LIGHTWEIGHT CENTRIFUGAL FORCE...HEAT STRESS (PHYSIOLOGY) AIR FLOW VENTILATION PORTABLE EQUIPMENT PERSONAL COOLING SYSTEMS EFFICIENCY EVAPORATION INTEGRATED SYSTEMS PROTOTYPES...gH Vn ad s ad s 4 1 4 3     is angular speed (2rpm) V is volumetric flow rate Had is the fan pumping head (in meters) g is the

  14. A Review of Centrifugal Testing of Gasoline Contamination and Remediation

    OpenAIRE

    Jay N. Meegoda; Liming Hu

    2011-01-01

    Leaking underground storage tanks (USTs) containing gasoline represent a significant public health hazard. Virtually undetectable to the UST owner, gasoline leaks can contaminate groundwater supplies. In order to develop remediation plans one must know the extent of gasoline contamination. Centrifugal simulations showed that in silty and sandy soils gasoline moved due to the physical process of advection and was retained as a pool of free products above the water table. However, in clayey soi...

  15. Dynamical system analysis of unstable flow phenomena in centrifugal blower

    Directory of Open Access Journals (Sweden)

    Garcia David

    2015-09-01

    Full Text Available Methods of dynamical system analysis were employed to analyze unsteady phenomena in a centrifugal blower. Pressure signals gathered at different control points were decomposed into their Principal Components (PCs by means of Singular Spectrum Analysis (SSA. Certain number of PCs was considered in the analysis based on their statistical correlation. Projection of the original signal onto its PCs allowed to draw the phase trajectory that clearly separated non-stable blower working conditions from its regular operation.

  16. Scalp psoriasis associated with central centrifugal cicatricial alopecia

    Directory of Open Access Journals (Sweden)

    Krista N. Larson

    2017-01-01

    Full Text Available Scalp psoriasis is a very common dermatological condition with a variety of presentations, but only rarely presents as severe alopecia. We present a case of a 50-year-old female with many years of recalcitrant hair loss that was thought to be secondary to central centrifugal cicatricial alopecia which was later diagnosed as psoriasis. This case highlights an interesting presentation and rare complication of a common disease.

  17. Centrifuge modeling of rocking-isolated inelastic RC bridge piers

    OpenAIRE

    Loli, Marianna; Knappett, Jonathan A; Brown, Michael J.; Anastasopoulos, Ioannis; GAZETAS, George

    2014-01-01

    Experimental proof is provided of an unconventional seismic design concept, which is based on deliberately underdesigning shallow foundations to promote intense rocking oscillations and thereby to dramatically improve the seismic resilience of structures. Termed rocking isolation, this new seismic design philosophy is investigated through a series of dynamic centrifuge experiments on properly scaled models of a modern reinforced concrete (RC) bridge pier. The experimental method reproduces th...

  18. Computational and Experimental Study of an Industrial Centrifugal Compressor Volute

    Institute of Scientific and Technical Information of China (English)

    HarriPitkanen; HannuEsa; 等

    2000-01-01

    A centrifugal compressor with a vaneless diffuser was studied experimentally and numericallly.The main target of the study was to analyze the volute flow.Two different volute geometries was studied.The numerical solution was done by using a steady-state RANS code at both design and off-design conditions.Both calculated and measured pressure and velocity distributions are presented.

  19. Effect of centrifugal forces on dimensional error of bored shapes

    Science.gov (United States)

    Arsuaga, M.; de Lacalle, L. N. López; Lobato, R.; Urbikain, G.; Campa, F.

    2012-04-01

    Boring operations of deep holes with a slender boring bar are often hindered by the precision because of their low static stiffness and high deformations. Because of that, it is not possible to remove much larger depths of cuts than the nose radius of the tool, unlike the case of turning and face milling operations, and consequently, the relationship between the cutting force distribution, tool geometry, feed rate and depth of cut becomes non-linear and complex. This problem gets worse when working with a rotating boring head where apart from the cutting forces and the variation of the inclination angle because of shape boring, the bar and head are affected by de centrifugal forces. The centrifugal forces, and therefore the centrifugal deflection, will vary as a function of the rotating speed, boring bar mass distribution and variable radial position of the bar in shape boring. Taking in to account all this effects, a load and deformation model was created. This model has been experimentally validated to use as a corrector factor of the radial position of the U axis in the boring head.

  20. Modelling of horizontal centrifugal casting of work roll

    Science.gov (United States)

    Xu, Zhian; Song, Nannan; Tol, Rob Val; Luan, Yikun; Li, Dianzhong

    2012-07-01

    A numerical model to simulate horizontal centrifugal roll castings is presented in this paper. In order to simulate the flow fluid and solidification of horizontal centrifugal roll casting correctly, the model uses a body fitted mesh technique to represent the geometry. This new method maps a plate layer mesh to a circular mesh. The smooth body fitted mesh method gives more accurate calculation results for cylindrical geometries. A velocity depending on the angular velocity and inner radius of the mould is set up as a velocity boundary condition. The fluid flow coupled with heat transfer and solidification in a rapidly rotating roll is simulated. A gravity free falling method is applied as a pouring condition. A moveable pouring system is also used in the simulations. High speed steel is used to produce the work roll. Two different gating positions and a moveable gating system are simulated in this paper. Results show that the position of pouring system has a significant influence on the temperature distribution. The temperature distribution at a fixed central pouring system is more favourable than the distribution from a side pouring system. A moving gating system method is a better way to obtain a uniform temperature field in centrifugal casting and offers an alternative for existing techniques.

  1. Subchronic centrifugal mechanical assist in an unheparinized calf model.

    Science.gov (United States)

    Wagner-Mann, C; Curtis, J; Mann, F A; Turk, J; Demmy, T; Turpin, T

    1996-06-01

    The purpose of this study was to determine whether the major centrifugal pumps currently in use in the United States (Medtronic, BioMedicus BioPump and Carmeda-coated BioPump, Sarns 3M centrifugal pump, and St. Jude Medical Lifestream) could function as left mechanical assist devices in the subchronic (72 h) unheparinized calf model. Calves were instrumented for left atrial to aorta ex vivo assist, and the pump flow was set at 3.5 +/- 0.4 L/min. Two calves (Sarns 3M and St. Jude) survived 72 h of pumping without clinical complications. The other 2 calves died at 62 and 66 h (Medtronic BioPump and Carmeda-coated BioPump, respectively); both had pelvic limb paralysis. The seal of the Sarns 3M pump head ruptured after approximately 36 h of pumping and required replacement. On postmortem examination, pump-associated thromboembolic lesions were detected in 3 of the 4 calves in one or more of the following organs: kidneys, pancreas, abomasum, duodenum, ileum, spleen, and lumbar spinal cord. The calf with the Sarns 3M pump had no discernable lesions. Because of the clinical abnormalities and postmortem lesions in the unheparinized calf model, it was suggested that anticoagulation is necessary for conducting centrifugal mechanical assist studies in calves using presently available technology.

  2. Governing Principles of Alginate Microparticle Synthesis with Centrifugal Forces.

    Science.gov (United States)

    Eral, Huseyin Burak; Safai, Eric R; Keshavarz, Bavand; Kim, Jae Jung; Lee, Jisoek; Doyle, P S

    2016-07-19

    A controlled synthesis of polymeric particles is becoming increasingly important because of emerging applications ranging from medical diagnostics to self-assembly. Centrifugal synthesis of hydrogel microparticles is a promising method, combining rapid particle synthesis and the ease of manufacturing with readily available laboratory equipment. This method utilizes centrifugal forces to extrude an aqueous polymer solution, sodium alginate (NaALG) through a nozzle. The extruded solution forms droplets that quickly cross-link upon contact with aqueous calcium chloride (CaCl2) solution to form hydrogel particles. The size distribution of hydrogel particles is dictated by the pinch-off behavior of the extruded solution through a balance of inertial, viscous, and surface tension stresses. We identify the parameters dictating the particle size and provide a numerical correlation predicting the average particle size. Furthermore, we create a phase map identifying different pinch-off regimes (dripping without satellites, dripping with satellites, and jetting), explaining the corresponding particle size distributions, and present scaling arguments predicting the transition between regimes. By shedding light on the underlying physics, this study enables the rational design and operation of particle synthesis by centrifugal forces.

  3. Prenatal centrifugation: A model for fetal programming of adult weight?

    Science.gov (United States)

    Baer, Lisa A.; Rushing, Linda; Wade, Charles E.; Ronca, April E.

    2005-08-01

    'Fetal programming' is a newly emerging field that is revealing astounding insights into the prenatal origins of adult disease, including metabolic, endocrine, and cardiovascular pathophysiology. In the present study, we tested the hypothesis that rat pups conceived, gestated and born at 2-g have significantly reduced birth weights and increased adult body weights as compared to 1-g controls. Offspring were produced by mating young adult male and female rats that were adapted to 2-g centrifugation. Female rats underwent conception, pregnancy and birth at 2-g. Newborn pups in the 2-g condition were removed from the centrifuge and fostered to non-manipulated, newly parturient dams maintained at 1-g. Comparisons were made with 1-g stationary controls, also cross- fostered at birth. As compared to 1-g controls, birth weights of pups gestated and born at 2-g were significantly reduced. Pup body weights were significantly reduced until Postnatal day (P)12. Beginning on P63, body weights of 2-g-gestated offspring exceeded those of 1-g controls by 7-10%. Thus, prenatal rearing at 2-g restricts neonatal growth and increases adult body weight. Collectively, these data support the hypothesis that 2-g centrifugation alters the intrauterine milieu, thereby inducing persistent changes in adult phenotype.

  4. Numerical Analysis and Centrifuge Modeling of Shallow Foundations

    Institute of Scientific and Technical Information of China (English)

    罗强; 栾茂田; 杨蕴明; 王忠涛; 赵守正

    2014-01-01

    The influence of non-coaxial constitutive model on predictions of dense sand behavior is investigated in this paper. The non-coaxial model with strain softening plasticity is applied into finite-element program ABAQUS, which is first used to predict the stress-strain behavior and the non-coaxial characteristic between the orientations of the principal stress and principal plastic strain rate in simple shear tests. The model is also used to predict load settlement responses and bearing capacity factors of shallow foundations. A series of centrifuge tests for shallow foundations on saturated dense sand are performed under drained conditions and the test results are compared with the corresponding numerical results. Various footing dimensions, depths of embedment, and footing shapes are considered in these tests. In view of the load settlement relationships, the stiffness of the load-displacement curves is significantly affected by the non-coaxial model compared with those predicted by the coaxial model, and a lower value of non-coaxial modulus gives a softer response. Considering the soil behavior at failure, the coaxial model predictions of bearing capacity factors are more advanced than those of centrifuge test results and the non-coaxial model results;besides, the non-coaxial model gives better predictions. The non-coaxial model predictions are closer to those of the centrifuge results when a proper non-coaxial plastic modulus is chosen.

  5. A new practice in fruit trees: Centrifugal training system

    Directory of Open Access Journals (Sweden)

    Ersin ATAY

    2013-06-01

    Full Text Available The choice of the training system is a rather important decision for yield, fruit quality and profitability. There were dramatic changes in concepts for apple training in the last years. Centrifugal training system which was one of the innovations was developed in the beginning of the 2000’s in France. SolAxe training system forms the main part of this training system. The most innovative aspect of the Centrifugal training system is the artificial extinction technique. This technique is carried out more specifically in the center of the tree and on the underside of branches to remove potentially poor quality fruits. Artificial extinction improves light distribution within the tree canopy especially in colored-fruit varieties for which the light climate is particularly important. It also offers an alternative training method to reduce biennial bearing. In addition to canopy porosity created by artificial extinction, this training system can help reducing disease and harmful insects. In this study it is aimed to explain general rules of centrifugal training system.

  6. Calculations of the Acceleration of Centrifugal Loading on Adherent Cells

    Science.gov (United States)

    Chen, Kang; Song, Yang; Liu, Qing; Zhang, Chunqiu

    2017-07-01

    Studies have shown that the morphology and function of living cells are greatly affected by the state of different high acceleration. Based on the centrifuge, we designed a centrifugal cell loading machine for the mechanical biology of cells under high acceleration loading. For the machine, the feasibility of the experiment was studied by means of constant acceleration or variable acceleration loading in the Petri dish fixture and/or culture flask. Here we analyzed the distribution of the acceleration of the cells with the change of position and size of the culturing device quantitatively. It is obtained that Petri dish fixture and/or culture flask can be used for constant acceleration loading by experiments; the centripetal acceleration of the adherent cells increases with the increase of the distance between the rotor center of the centrifuge and the fixture of the Petri dish and the size of the fixture. It achieves the idea that the general biology laboratory can conduct the study of mechanical biology at high acceleration. It also provides a basis for more accurate study of the law of high acceleration on mechanobiology of cells.

  7. Sperm fractions obtained following density gradient centrifugation in human ejaculates show differences in sperm DNA longevity

    Institute of Scientific and Technical Information of China (English)

    Jaime Goslvez; Stephen Johnston; Carmen Lpez-Fernndez; Altea Goslbez; Francisca Arroyo; Jose Lus Fernndez; Juan G lvarez

    2014-01-01

    Objective:To investigate the DNA longevity characteristics associated with each resultant fraction following density gradient centrifugation (DGC) in comparison to that of the original neat ejaculated sample. Methods:An aliquot of neat semen (NSS) collected from 7 patients was processed using DGC resulting in 3 fractions;Fraction 1:seminal plasma/40%gradient interface (GI);Fraction 2:40%GI/80%GI;Fraction 3:80%GI/pellet. An aliquot of each fraction and NSS was cryopreserved, thawed and incubated at 37 ℃for 24h;the increase of sperm DNA fragmentation was assessed using the Dyn-Halosperm assay following 0, 3, 6 and 24h of incubation. Results:While there was a significant reduction in the incidence of baseline sperm DNA fragmentation following DGC in Fraction 3, sperm DNA longevity was shown to be higher in the NSS than in any other sub-population following incubation. The highest levels of baseline DNA damage were found in Fractions 1 and 2;these fractions also showed the highest rate DNA fragmentation following incubation, subsequently exhibiting the lowest DNA longevity. Conclusion:1) Unnecessary incubation of spermatozoa prior to artificial insemination or in vitro fertilization, should be avoided, since sperm DNA longevity is significantly reduced after ex vivo sperm handling and 2) Although sperm selection by DCG significantly reduces the baseline levels of SDF of sperm in Fraction 3, sperm DNA longevity in this fraction was ultimately lower following 24 h incubation when compared to sperm recovered from non-centrifuged NSS.

  8. [Plasma and tissue lipids in rats after a flight on the Kosmos-936 biosatellite].

    Science.gov (United States)

    Ahlers, J; Tigranian, R A; Praslická, M

    1982-01-01

    The content of triglycerides, total cholesterol, phospholipids and nonesterified fatty acids was measured in plasma and tissues of rats flown for 18.5 days on Cosmos-936 in the weightless and centrifuged state. The weightlessness exposure increased lipid fractions in plasma and tissues, and artificial gravity produced a beneficial effect.

  9. Tethys and Dione as sources of outward-flowing plasma in Saturn's magnetosphere.

    Science.gov (United States)

    Burch, J L; Goldstein, J; Lewis, W S; Young, D T; Coates, A J; Dougherty, M K; André, N

    2007-06-14

    Rotating at over twice the angular speed of Earth, Saturn imposes a rapid spin on its magnetosphere. As a result, cold, dense plasma is believed to be flung outward from the inner magnetosphere by centrifugal force and replaced by hotter, more tenuous plasma from the outer magnetosphere. The centrifugal interchange of plasmas in rotating magnetospheres was predicted many years ago and was conclusively demonstrated by observations in Jupiter's magnetosphere, which--like that of Saturn (but unlike that of Earth)--is rotationally dominated. Recent observations in Saturn's magnetosphere have revealed narrow injections of hot, tenuous plasma believed to be the inward-moving portion of the centrifugal interchange cycle. Here we report observations of the distribution of the angle between the electron velocity vector and the magnetic field vector ('pitch angle') obtained in the cold, dense plasma adjacent to these inward injection regions. The observed pitch-angle distributions are indicative of outward plasma flow and consistent with centrifugal interchange in Saturn's magnetosphere. Further, we conclude that the observed double-peaked ('butterfly') pitch-angle distributions result from the transport of plasma from regions near the orbits of Dione and Tethys, supporting the idea of distinct plasma tori associated with these moons.

  10. Water Drainage from Unsaturated Soils in a Centrifuge Permeameter

    Science.gov (United States)

    Ornelas, G.; McCartney, J.; Zhang, M.

    2013-12-01

    This study involves an analysis of water drainage from an initially saturated silt layer in a centrifuge permeameter to evaluate the hydraulic properties of the soil layer in unsaturated conditions up to the point where the water phase becomes discontinuous. These properties include the soil water retention curve (SWRC) and the hydraulic conductivity function (HCF). The hydraulic properties of unsaturated silt are used in soil-atmosphere interaction models that take into account the role of infiltration and evaporation of water from soils due to atmospheric interaction. These models are often applied in slope stability analyses, landfill cover design, aquifer recharge analyses, and agricultural engineering. The hydraulic properties are also relevant to recent research concerning geothermal heating and cooling, as they can be used to assess the insulating effects of soil around underground heat exchangers. This study employs a high-speed geotechnical centrifuge to increase the self-weight of a compacted silt specimen atop a filter plate. Under a centrifuge acceleration of N times earth's gravity, the concept of geometric similitude indicates that the water flow process in a small-scale soil layer will be similar to those in a soil layer in the field that is N times thicker. The centrifuge acceleration also results in an increase in the hydraulic gradient across the silt specimen, which causes water to flow out of the pores following Darcy's law. The drainage test was performed until the rate of liquid water flow out of the soil layer slowed to a negligible level, which corresponds to the transition point at which further water flow can only occur due to water vapor diffusion following Fick's law. The data from the drainage test in the centrifuge were used to determine the SWRC and HCF at different depths in the silt specimen, which compared well with similar properties defined using other laboratory tests. The transition point at which liquid water flow stopped (and

  11. Microstructures of Al-Al3Ti functionally graded materials fabricated by centrifugal solid-particle method and centrifugal in situ method

    Science.gov (United States)

    Watanabe, Yoshimi; Zhou, Qi; Sato, Hisashi; Fujii, Toshiyuki; Inamura, Tomonari

    2017-01-01

    Methods of fabrication by centrifugal casting for functionally graded materials (FGMs) can be classified into two categories on the basis of the relationship between the process temperature and the liquidus temperature of a master alloy. They are the centrifugal solid-particle method and centrifugal in situ method, which could be carried out at process temperatures lower and higher than the liquidus temperature of the master alloy, respectively. In a previous study, it was found that the microstructures of Al-Al3Ti FGMs fabricated by the centrifugal in situ method processed at 1600 °C were different from those fabricated by the centrifugal solid-particle method processed at 800 °C. Although it is expected that the FGMs fabricated by the centrifugal in situ method processed at approximately the liquidus temperature should show extraordinary microstructures, those microstructures have not been observed. In this study, the microstructures of Al-Al3Ti FGMs fabricated at 1000 °C (centrifugal solid-particle method) and 1200 °C (centrifugal in situ method) were investigated.

  12. Hemolysis during cardiac extracorporeal membrane oxygenation: a case-control comparison of roller pumps and centrifugal pumps in a pediatric population.

    Science.gov (United States)

    Byrnes, Jonathan; McKamie, Wes; Swearingen, Christopher; Prodhan, Parthak; Bhutta, Adnan; Jaquiss, Robert; Imamura, Michiaki; Fiser, Richard

    2011-01-01

    Extracorporeal membrane oxygenation (ECMO) is a lifesaving therapy, which has been used for the support of children with a broad range of diseases. Two pumps of differing mechanisms have been used to generate the extracorporeal flow: roller-head pumps and centrifugal pumps. Seven patients supported during ECMO with Levitronix Centrimag (Centrimag group [CG]) were matched to 14 patients supported with Stockert-Shiley SIII (Stockert-Shiley group [SSG]) at a single institution from July 2007 to July 2009. We hypothesized that hemolysis as measured by plasma-free hemoglobin (PFH) is elevated in the SSG versus the CG during cardiac ECMO. Categorical data were analyzed using Fisher's exact test. Plasma-free hemoglobin differences between groups were analyzed using both Wilcoxon rank sum and beta regression. Overall, SSG patients had two times the odds of having a higher PFH than CG patients adjusting for repeated measures (odds ratio [OR] = 1.96, 95% confidence interval [CI]: [1.15-3.34], p pump supported group, when compared with the CG, a centrifugal pump supported group. Differences in circuit life did not reach statistical significance. This pilot study contrasts with past studies, which have demonstrated more hemolysis occurring with centrifugal pumps when compared with roller-head pumps.

  13. Asparaginase-associated concurrence of hyperlipidemia, hyperglobulinemia, and thrombocytosis was successfully treated by centrifuge/membrane hybrid double-filtration plasmapheresis.

    Science.gov (United States)

    Wang, Taina; Xu, Bin; Fan, Rong; Liu, Zhihong; Gong, Dehua

    2016-01-01

    Asparaginase-associated concurrence of hyperlipidemia, hyperglobulinemia, and thrombocytosis is a rare complication requiring aggressive lipoprotein apheresis, but no one of currently available lipoprotein apheresis methods can simultaneously resolve the 3 abnormalities. Herein, we reported a construction of double-filtration plasmapheresis (DFPP) using a combination of centrifugal/membranous plasma separation techniques to successfully treat a patient with hyperlipidemia, hyperglobulinemia, and thrombocytosis. A male presented with severe hyperlipidemia, hyperglobulinemia, and thrombocytosis during asparaginase treatment for NK/T-cell lymphoblastic lymphoma and was scheduled to receive lipoprotein apheresis. To simultaneously remove lipoproteins, immunoglobulin, and deplete platelets from blood, a centrifuge/membrane hybrid DFPP was constructed as following steps: plasma and part of platelets were separated first from whole blood by centrifugal technique and then divided by a fraction plasma separator into 2 parts: platelets and plasma components with large size, which were discarded; and those containing albumin, which were returned to blood with a supplement of extrinsic albumin solution. DFPP lasted 240 minutes uneventfully, processing 5450-mL plasma. The concentrations of plasma components before DFPP were as follows: triglycerides 38.22 mmol/L, total cholesterols 22.98 mmol/L, immunoglobulin A (IgA) 15.7 g/L, IgG 12.7 g/L, and IgM 14.3 g/L; whereas after treatment were 5.69 mmol/L, 2.38 mmol/L, 2.5 g/L, 7.7 g/L, and 0.4 g/L, respectively. The respective reduction ratio was 85.1%, 89.6%, 83.9%, 39.4%, and 96.9%. Platelet count decreased by 40.4% (from 612 × 10(9)/L to 365 × 10(9)/L). Centrifuge/membrane hybrid DFPP can simultaneously remove lipoproteins, immunoglobulin, and deplete platelets, with a success in treatment of asparaginase treatment-induced hyperlipidemia, hyperglobulinemia, and thrombocytosis, and may be useful for patients

  14. Plasma rico en plaquetas Platelet -rich plasma

    Directory of Open Access Journals (Sweden)

    J. González Lagunas

    2006-04-01

    Full Text Available El Plasma Rico en Plaquetas es una suspensión concentrada de la sangre centrifugada que contiene elevadas concentraciones de trombocitos. Durante los últimos años, este producto ha aparecido de forma repetida en publicaciones científicas y en medios de comunicación generales como un producto que por sus características induce la curación y regeneración de los tejidos. La premisa de su uso es que las elevadas concentraciones de plaquetas en el PRP, liberan cantidades significativas de factores de crecimiento. En este artículo se van a recoger las evidencias científicas que se han presentado en la literatura médica con respecto al PRP y a la curación ósea, así como las diferentes aplicaciones clínicas que se han sugerido.Platelet-rich plasma is a by-product of centrifuged whole blood that contains high levels of thrombocytes. In the last decade, scientific and media interest has been generated by this product that apparently has the capacity of inducing and promoting tissue healing and regeneration. The premise of its use is that the large number of platelets in PRP release significant amounts of growth factors. In this paper, a critical review of the medical literature regarding PRP and bone healing will be presented. Also, the suggested clinical applications of the product will be addressed.

  15. Enriched surface acidity for surfactant-free suspensions of carboxylated carbon nanotubes purified by centrifugation

    Directory of Open Access Journals (Sweden)

    Elizabeth I. Braun

    2016-06-01

    Full Text Available It is well known that surfactant-suspended carbon nanotube (CNT samples can be purified by centrifugation to decrease agglomerates and increase individually-dispersed CNTs. However, centrifugation is not always part of protocols to prepare CNT samples used in biomedical applications. Herein, using carboxylated multi-walled CNTs (cMWCNTs suspended in water without a surfactant, we developed a Boehm titrimetric method for the analysis of centrifuged cMWCNT suspensions and used it to show that the surface acidity of oxidized carbon materials in aqueous cMWCNT suspensions was enriched by ∼40% by a single low-speed centrifugation step. This significant difference in surface acidity between un-centrifuged and centrifuged cMWCNT suspensions has not been previously appreciated and is important because the degree of surface acidity is known to affect the interactions of cMWCNTs with biological systems.

  16. Bioreactor-free tissue engineering: directed tissue assembly by centrifugal casting.

    Science.gov (United States)

    Mironov, Vladimir; Kasyanov, Vladimir; Markwald, Roger R; Prestwich, Glenn D

    2008-02-01

    Casting is a process by which a material is introduced into a mold while it is liquid, allowed to solidify in a predefined shape inside the mold, and then removed to give a fabricated object, part or casing. Centrifugal casting could be defined as a process of molding using centrifugal forces. Although the centrifugal casting technology has a long history in metal manufacturing and in the plastics industry, only recently has this technology attracted the attention of tissue engineers. Initially, centrifugation was used to optimize cell seeding on a solid scaffold. More recently, centrifugal casting has been used to create tubular scaffolds and both tubular and flat multilayered, living tissue constructs. These newer applications were enabled by a new class of biocompatible in situ crosslinkable hydrogels that mimic the extracellular matrix. Herein the authors summarize the state of the art of centrifugal casting technology in tissue engineering, they outline associated technological challenges, and they discuss the potential future for clinical applications.

  17. Mathematical model of the component mixture distribution in the molten cast iron during centrifugation (sedimentation)

    Science.gov (United States)

    Bikulov, R. A.; Kotlyar, L. M.

    2014-12-01

    For the development and management of the manufacturing processes of axisymmetric articles with compositional structure by centrifugal casting method [1,2,3,4] is necessary to create a generalized mathematical model of the dynamics of component mixture in the molten cast iron during centrifugation. In article. based on the analysis of the dynamics of two-component mixture at sedimentation, a method of successive approximations to determine the distribution of a multicomponent mixture by centrifugation in a parabolic crucible is developed.

  18. Topological analysis of the formation of Jet-Wake flow pattern in centrifugal impeller channel

    Institute of Scientific and Technical Information of China (English)

    ZHENG Qun; LIU Shun-long

    2004-01-01

    Topological analyses are carried out for the numerical results of internal flow field in centrifugal impeller. Topological rules of the singular point characteristics of the limiting streamline are derived and used to determine three dimensional separation patterns in centrifugal impeller and to verify the numerical results. The results reveal that the wake is saddle to nodal closed separation and the formation, its onset point and its developing process of Jet-Wake Flow pattern in centrifugal impeller are presented in this paper.

  19. Silver nanodisks: size selection via centrifugation and optical properties.

    Science.gov (United States)

    Germain, V; Brioude, A; Ingert, D; Pileni, M P

    2005-03-22

    Silver nanodisks, having two different sizes, and spherical particles are synthesized by soft chemistry. By using centrifugation, nanodisks are mainly selected. The experimental absorption spectra of these nanodisks with different sizes are compared to those simulated using the discrete dipole approximation method. For small nanodisk sizes, the nanodisk shape is neglected and the simulated spectra closest to the experiments are obtained by assuming a spheroidal particle. Conversely, for larger nanodisks, the precise geometries represented by snip and aspect ratio are needed for good agreement between experiments and simulations.

  20. OFF-DESIGN OPERATION OF IMPELLER OF THE CENTRIFUGAL COMPRESSOR

    Directory of Open Access Journals (Sweden)

    Saim KOÇAK

    2004-02-01

    Full Text Available Inducer and discharge dimensions of impellers of centrifugal compressor are determined as a preliminary design. Blockage factor and inducer dimensionless mass flow are exercised in relation with the relative Mach number. The equation which will be based o off-design calculation, related with the discharge relative Mach number are iterated until it will equal to inducer dimensionless mass flow rate. Then discharge relative Mach number for off-design works is obtained. The results calculated in accordance with pressure, temperature and density are seen to be similar with the theoretical parameters.

  1. Capture into resonance and phase space dynamics in optical centrifuge

    CERN Document Server

    Armon, Tsafrir

    2016-01-01

    The process of capture of a molecular enesemble into rotational resonance in the optical centrifuge is investigated. The adiabaticity and phase space incompressibility are used to find the resonant capture probability in terms of two dimensionless parameters P1,P2 characterising the driving strength and the nonlinearity, and related to three characteristic time scales in the problem. The analysis is based on the transformation to action-angle variables and the single resonance approximation, yielding reduction of the three-dimensional rotation problem to one degree of freedom. The analytic results for capture probability are in a good agreement with simulations. The existing experiments satisfy the validity conditions of the theory.

  2. Methods of observation of the centrifugal quantum states of neutrons

    Science.gov (United States)

    Cubitt, R.; Nesvizhevsky, V. V.; Petukhov, A. K.; Voronin, A. Yu.; Pignol, G.; Protasov, K. V.; Gurshijants, P.

    2009-12-01

    We propose methods for observation of the quasi-stationary states of neutrons, localized near a curved mirror surface. The bounding effective well is formed by the centrifugal potential and the mirror's optical potential. This phenomenon is an example of an exactly solvable "quantum bouncer" problem that can be studied experimentally. It could provide a new tool for studying fundamental neutron-matter interactions, neutron quantum optics and surface physics effects. The feasibility of observation of such quantum states has been proven in first experiments.

  3. Methods of observation of the centrifugal quantum states of neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Cubitt, R. [Institut Laue-Langevin (ILL), 6 rue Jules Horowitz, F-38042 Grenoble (France); Nesvizhevsky, V.V., E-mail: nesvizhevsky@ill.e [Institut Laue-Langevin (ILL), 6 rue Jules Horowitz, F-38042 Grenoble (France); Petukhov, A.K. [Institut Laue-Langevin (ILL), 6 rue Jules Horowitz, F-38042 Grenoble (France); Voronin, A.Yu., E-mail: dr.a.voronin@gmail.co [P.N. Lebedev Physical Institute, 53 Leninsky Prospekt, 119991 Moscow (Russian Federation); Pignol, G.; Protasov, K.V. [Laboratoire de Physique Subatomique et de Cosmologie (LPSC), IN2P3-CNRS, UJF, 53, Avenue des Martyrs, F-38026 Grenoble (France); Gurshijants, P. [Institute of Solid State Physics (ISSP), Institutskaya Street 2, 142432 Chernogolovka, Moscow Region (Russian Federation)

    2009-12-11

    We propose methods for observation of the quasi-stationary states of neutrons, localized near a curved mirror surface. The bounding effective well is formed by the centrifugal potential and the mirror's optical potential. This phenomenon is an example of an exactly solvable 'quantum bouncer' problem that can be studied experimentally. It could provide a new tool for studying fundamental neutron-matter interactions, neutron quantum optics and surface physics effects. The feasibility of observation of such quantum states has been proven in first experiments.

  4. Centrifugal experimental study of suction bucket foundations under dynamic loading

    Science.gov (United States)

    Lu, Xiaobing; Wu, Yongren; Jiao, Bintian; Wang, Shuyun

    2007-12-01

    Centrifugal experiments were carried out to investigate the responses of suction bucket foundations under horizontal and vertical dynamic loading. It is shown that when the loading amplitude is over a critical value, the sand at the upper part around the bucket is softened or even liquefied. The excess pore pressure decreases from the upper part to the lower part of the sand layer in the vertical direction and decreases radially from the bucket’s side wall in the horizontal direction. Large settlements of the bucket and the sand layer around the bucket are induced by dynamic loading. The dynamic responses of the bucket with smaller height (the same diameter) are heavier.

  5. Size-isolation of ultrasound-mediated phase change perfluorocarbon droplets using differential centrifugation.

    Science.gov (United States)

    Mercado, Karla P; Radhakrishnan, Kirthi; Stewart, Kyle; Snider, Lindsay; Ryan, Devin; Haworth, Kevin J

    2016-05-01

    Perfluorocarbon droplets that are capable of an ultrasound-mediated phase transition have applications in diagnostic and therapeutic ultrasound. Techniques to modify the droplet size distribution are of interest because of the size-dependent acoustic response of the droplets. Differential centrifugation has been used to isolate specific sizes of microbubbles. In this work, differential centrifugation was employed to isolate droplets with diameters between 1 and 3 μm and 2 and 5 μm from an initially polydisperse distribution. Further, an empirical model was developed for predicting the droplet size distribution following differential centrifugation and to facilitate the selection of centrifugation parameters for obtaining desired size distributions.

  6. Computer precision simulation for titanium casting centrifugal mold filling of prescision titanium castings

    Directory of Open Access Journals (Sweden)

    Daming XU

    2004-08-01

    Full Text Available Computer simulation codes were developed based on proposed mathematical model for centrifugal mold filling processes and previous computer software for 3D mold filling and solidification of castings. Sample simulations were implemented for mold filling processes of precision titanium castings under gravity and different centrifugal casting techniques. The computation results show that the alloy melt has a much stronger mold filling ability for thin section castings unde a centrifugal force field than that only under the gravity. A "return back" mold filling manner is showed to be a reasonable technique for centrifugal casting processes, especially for thin section prcision castings.

  7. Adiabatic field-free alignment of asymmetric top molecules with an optical centrifuge

    CERN Document Server

    Korobenko, A

    2015-01-01

    We use an optical centrifuge to align asymmetric top $\\mathrm{SO_2}$ molecules by adiabatically spinning their most polarizable O-O axis. The effective centrifugal potential in the rotating frame confines sulfur atoms to the plane of the laser-induced rotation, leading to the planar molecular alignment which persists after the molecules are released from the centrifuge. Periodic appearance of the full three-dimensional alignment, typically observed only with linear and symmetric top molecules, is also detected. Together with strong in-plane centrifugal forces, which bend the molecules by up to 10 degrees, permanent field-free alignment offers new ways of controlling molecules with laser light.

  8. High Order Centrifugal Distortion Corrections to Energy Levels of Asymmetric Top Molecules

    Institute of Scientific and Technical Information of China (English)

    LIU Yu-Yan; LIU Xiao-Yong; LIU Hong-Ping; GUO Yuan-Qing; HUANG Guang-Ming; LIN Jie-Li; GAO Hui

    2000-01-01

    High order centrifugal distortion terms have been derived and added to the effective Hamiltonian of asymmetric top molecules. Based on this Hamiltonian, a program in Fortran 77 has been developed for spectral analysis of asymmetric top molecules. The high order centrifugal distortion terms are found to be non-negligible even for the low-lying rotational transitions of molecules, such as Ha 18O, subjected to severe centrifugal distortion effect,and for the high-lying rotational transitions of molecules, such as 14N16O2 subjected to the moderate centrifugal distortion effect.

  9. Alpha Channeling in a Rotating Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Abraham J. Fetterman and Nathaniel J. Fisch

    2008-09-23

    The wave-particle α-channeling effect is generalized to include rotating plasma. Specifically, radio frequency waves can resonate with α particles in a mirror machine with E × B rotation to diffuse the α particles along constrained paths in phase space. Of major interest is that the α-particle energy, in addition to amplifying the RF waves, can directly enhance the rotation energy which in turn provides additional plasma confinement in centrifugal fusion reactors. An ancillary benefit is the rapid removal of alpha particles, which increases the fusion reactivity.

  10. A flowing plasma model to describe drift waves in a cylindrical helicon discharge

    CERN Document Server

    Chang, L; Cormac, C S

    2011-01-01

    A two-fluid model developed originally to describe wave oscillations in the vacuum arc centrifuge, a cylindrical, rapidly rotating, low temperature and confined plasma column, is applied to interpret plasma oscillations in a RF generated linear magnetised plasma (WOMBAT), with similar density and field strength. Compared to typical centrifuge plasmas, WOMBAT plasmas have slower normalised rotation frequency, lower temperature and lower axial velocity. Despite these differences, the two-fluid model provides a consistent description of the WOMBAT plasma configuration and yields qualitative agreement between measured and predicted wave oscillation frequencies with axial field strength. In addition, the radial profile of the density perturbation predicted by this model is consistent with the data. Parameter scans show that the dispersion curve is sensitive to the axial field strength and the electron temperature, and the dependence of oscillation frequency with electron temperature matches the experiment. These r...

  11. [Plasma exchange in nephrology: Indications and technique].

    Science.gov (United States)

    Ridel, Christophe; Kissling, Sébastien; Mesnard, Laurent; Hertig, Alexandre; Rondeau, Éric

    2017-02-01

    Plasma exchange is a non-selective apheresis technique that can be performed by filtration or centrifugation allowing rapid purification of high molecular weight pathogens. An immunosuppressive treatment is generally associated to reduce the rebound effect of the purified substance. Substitution solutes such as human albumin and macromolecules are needed to compensate for plasma extraction. Compensation by viro-attenuated plasma is reserved solely for the treatment of thrombotic microangiopathies or when there is a risk of bleeding, because this product is very allergenic and expensive. The treatment goal for a plasma exchange session should be between one and one and one-half times the patient's plasma volume estimated at 40 mL/kg body weight. The anticoagulation is best ensured by the citrate. Complications of plasma exchange are quite rare according to the French hemapheresis registry. The level of evidence of efficacy of plasma exchange in nephrology varies from one pathology to another. Main indications of plasma exchange in nephrology are Goodpasture syndrome, antineutrophil cytoplasmic antibody vasculitis when plasma creatinine is greater than 500 μmol/L, and thrombotic microangiopathies. During renal transplantation, plasma exchange may be proposed in the context of human leukocyte antigen (HLA) desensitization protocols or ABO-incompatible graft. After renal transplantation, plasma exchange is indicated as part of the treatment of acute humoral rejection or recurrent focal segmental glomerulosclerosis on the graft. Plasma exchanges are also proposed in the management of cryoglobulinemia or polyarteritis nodosa. Hemodialysis with membranes of very high permeability tends to replace plasma exchange for myeloma nephropathy. The benefit from plasma exchange has not been formally demonstrated for the treatment of severe lupus or antiphospholipid antibody syndrome. There is no indication of plasma exchange in the treatment of scleroderma or nephrogenic

  12. LISSAT Analysis of a Generic Centrifuge Enrichment Plant

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, H; Elayat, H A; O?Connell, W J; Szytel, L; Dreicer, M

    2007-05-31

    The U.S. Department of Energy (DOE) is interested in developing tools and methods for use in designing and evaluating safeguards systems for current and future plants in the nuclear power fuel cycle. The DOE is engaging several DOE National Laboratories in efforts applied to safeguards for chemical conversion plants and gaseous centrifuge enrichment plants. As part of the development, Lawrence Livermore National Laboratory has developed an integrated safeguards system analysis tool (LISSAT). This tool provides modeling and analysis of facility and safeguards operations, generation of diversion paths, and evaluation of safeguards system effectiveness. The constituent elements of diversion scenarios, including material extraction and concealment measures, are structured using directed graphs (digraphs) and fault trees. Statistical analysis evaluates the effectiveness of measurement verification plans and randomly timed inspections. Time domain simulations analyze significant scenarios, especially those involving alternate time ordering of events or issues of timeliness. Such simulations can provide additional information to the fault tree analysis and can help identify the range of normal operations and, by extension, identify additional plant operational signatures of diversions. LISSAT analyses can be used to compare the diversion-detection probabilities for individual safeguards technologies and to inform overall strategy implementations for present and future plants. Additionally, LISSAT can be the basis for a rigorous cost-effectiveness analysis of safeguards and design options. This paper will describe the results of a LISSAT analysis of a generic centrifuge enrichment plant. The paper will describe the diversion scenarios analyzed and the effectiveness of various safeguards systems alternatives.

  13. Numerical modeling of centrifuge cyclic lateral pile load experiments

    Institute of Scientific and Technical Information of China (English)

    Nikos Gerolymos; Sandra Escoffer; George Gazetas; Jacques Gamier

    2009-01-01

    To gain insight into the inelastic behavior of piles, the response of a vertical pile embedded in dry sand and subjected to cyclic lateral loading was studied experimentally in centrifuge tests conducted in Laboratoire Central des Ponts et Chaussees. Three types of cyclic loading were applied, two asymmetric and one symmetric with respect to the unloaded pile. An approximately square-root variation of soil stiffness with depth was obtained from indirect in-flight density measurements, laboratory tests on reconstituted samples, and well-established empirical correlations. The tests were simulated using a cyclic nonlinear Winkler spring model, which describes the full range of inelastic phenomena, including separation and re-attachment of the pile from and to the soil. The model consists of three mathematical expressions capable of reproducing a wide variety of monotonic and cyclic experimental p-y curves. The physical meaning of key model parameters is graphically explained and related to soil behavior. Comparisons with the centrifuge test results demonstrate the general validity of the model and its ability to capture several features of pile-soil interaction, including: soil plastification at an early stage of loading, "pinching" behavior due to the formation of a relaxation zone around the upper part of the pile, and stiffness and strength changes due to cyclic loading. A comparison of the p-y curves derived from the test results and the proposed model, as well as those from the classical curves of Reese et al. (1974) for sand, is also presented.

  14. Flow in a Low Specific Speed Centrifugal Pump Using PIV

    Directory of Open Access Journals (Sweden)

    Cui Dai

    2013-01-01

    Full Text Available The interflow plays important roles in centrifugal pump design. In order to study the effect of rotation and z-axis on internal flow, two-dimensional particle image velocimetry (PIV measurements have been performed to measure the steady velocity field on three planes in all impeller passages of a low specific-speed centrifugal pump. The results show that the relative velocity flows in blade passages are obviously different in terms of the positions of the blade relative to the tongue. The interaction between the impeller and tongue changes the occurrence and development of low velocity region with time. From shroud to hub, the relative velocity gradually increases, and the minimum value moves toward the suction surface. On the midplane, the magnitude increases with increased flow rate from pressure surface to suction surface, while at the shroud and hub, the measured velocity first increases with decreased flow rate from the blade pressure surface to nearly ζ = 0.5 to 0.6.

  15. Centrifugal compression of soft particle packings: theory and experiment.

    Science.gov (United States)

    Nordstrom, K N; Verneuil, E; Ellenbroek, W G; Lubensky, T C; Gollub, J P; Durian, D J

    2010-10-01

    An exact method is developed for computing the height of an elastic medium subjected to centrifugal compression, for arbitrary constitutive relation between stress and strain. Example solutions are obtained for power-law media and for cases where the stress diverges at a critical strain--for example as required by packings composed of deformable but incompressible particles. Experimental data are presented for the centrifugal compression of thermo-responsive N-isopropylacrylamide (NIPA) microgel beads in water. For small radial acceleration, the results are consistent with Hertzian elasticity, and are analyzed in terms of the Young elastic modulus of the bead material. For large radial acceleration, the sample compression asymptotes to a value corresponding to a space-filling particle volume fraction of unity. Therefore we conclude that the gel beads are incompressible, and deform without deswelling. In addition, we find that the Young elastic modulus of the particulate gel material scales with cross-link density raised to the power 3.3±0.8, somewhat larger than the Flory expectation.

  16. Design and Characterization of a Centrifugal Compressor Surge Test Rig

    Directory of Open Access Journals (Sweden)

    Kin Tien Lim

    2011-01-01

    Full Text Available A detailed description of a new centrifugal compressor surge test rig is presented. The objective of the design and development of the rig is to study the surge phenomenon in centrifugal compression systems and to investigate a novel method of surge control by active magnetic bearing servo actuation of the impeller axial tip clearance. In this paper, we focus on the design, initial setup, and testing of the rig. The latter two include the commissioning of the rig and the experimental characterization of the compressor performance. The behavior of the compressor during surge is analyzed by driving the experimental setup into surge. Two fundamental frequencies, 21 Hz and 7 Hz, connected to the surge oscillation in the test rig are identified, and the observed instability is categorized according to the intensity of pressure fluctuations. Based on the test results, the excited pressure waves are clearly the result of surge and not stall. Also, they exhibit the characteristics of mild and classic surge instead of deep surge. Finally, the change in the compressor performance due to variation in the impeller tip clearance is experimentally examined, and the results support the potential of the tip clearance modulation for the control of compressor surge. This is the first such demonstration of the feasibility of surge control of a compressor using active magnetic bearings.

  17. Numerical Study of Unsteady Flow in Centrifugal Cold Compressor

    Science.gov (United States)

    Zhang, Ning; Zhang, Peng; Wu, Jihao; Li, Qing

    In helium refrigeration system, high-speed centrifugal cold compressor is utilized to pumped gaseous helium from saturated liquid helium tank at low temperature and low pressure for producing superfluid helium or sub-cooled helium. Stall and surge are common unsteady flow phenomena in centrifugal cold compressors which severely limit operation range and impact efficiency reliability. In order to obtain the installed range of cold compressor, unsteady flow in the case of low mass flow or high pressure ratio is investigated by the CFD. From the results of the numerical analysis, it can be deduced that the pressure ratio increases with the decrease in reduced mass flow. With the decrease of the reduced mass flow, backflow and vortex are intensified near the shroud of impeller. The unsteady flow will not only increase the flow loss, but also damage the compressor. It provided a numerical foundation of analyzing the effect of unsteady flow field and reducing the flow loss, and it is helpful for the further study and able to instruct the designing.

  18. Concrete Cleaning, Inc. centrifugal shot blaster: Baseline report; Greenbook (chapter)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-07-31

    The centrifugal shot blaster technology was tested and is being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU`s evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The centrifugal shot blaster is an electronically operated shot blast machine that has been modified to remove layers of concrete to varying depths. A hardened steel shot propelled at a high rate of speed abrades the surface of the concrete. The depth of material removed is determined by the rate of speed the machine is traveling and the volume of shot being fired into the blast chamber. The steel shot is recycled and used over until it is pulverized into dust, which ends up in the waste container with the concrete being removed. Debris is continually vacuumed by a large dust collection system attached to the shot blaster. The safety and health evaluation during the human factors assessment focused on two main areas: noise and dust.

  19. Platelet function and hemolysis in centrifugal pumps: in vitro investigations.

    Science.gov (United States)

    Steines, D; Westphal, D; Göbel, C; Reul, H; Rau, G

    1999-08-01

    The effects of centrifugal pumps on blood components other than erythrocytes, namely platelets and their interaction with the coagulation system, are not very well known. In a comparative study with three centrifugal pumps (BioMedicus BP-80, St. Jude Isoflow, and Sarns Delphin) and the Stockert roller pump hemolysis, platelet counts, thromboplastin and partial thromboplastin times, as well as resonance thrombography (RTG) parameters for the assessment of platelet and coagulation function were evaluated in vitro. Normalized indices of hemolysis (NIH) with ACD anticoagulation after 360 minutes were 0.008+/-0.004 (Isoflow), 0.018+/-0.017 (BP-80), 0.085+/-0.051 (Delphin), and 0.049+/-0.010 g/1001 (roller pump). Plasmatic coagulation was activated in all circuits. Platelet function was severely inhibited by the BP-80, indicated by increase in RTG platelet time to 358%+/-150% of initial values compared to 42%+/-29% (Isoflow), 40%+/-20% (Delphin), and 12%+/-10% (roller pump). Fibrin polymerization was affected similarly. The large surface area of the BP-80 leads to an extensive activation of platelets and plasminogen.

  20. Centrifuge modeling of rocking-isolated inelastic RC bridge piers

    Science.gov (United States)

    Loli, Marianna; Knappett, Jonathan A; Brown, Michael J; Anastasopoulos, Ioannis; Gazetas, George

    2014-01-01

    Experimental proof is provided of an unconventional seismic design concept, which is based on deliberately underdesigning shallow foundations to promote intense rocking oscillations and thereby to dramatically improve the seismic resilience of structures. Termed rocking isolation, this new seismic design philosophy is investigated through a series of dynamic centrifuge experiments on properly scaled models of a modern reinforced concrete (RC) bridge pier. The experimental method reproduces the nonlinear and inelastic response of both the soil-footing interface and the structure. To this end, a novel scale model RC (1:50 scale) that simulates reasonably well the elastic response and the failure of prototype RC elements is utilized, along with realistic representation of the soil behavior in a geotechnical centrifuge. A variety of seismic ground motions are considered as excitations. They result in consistent demonstrably beneficial performance of the rocking-isolated pier in comparison with the one designed conventionally. Seismic demand is reduced in terms of both inertial load and deck drift. Furthermore, foundation uplifting has a self-centering potential, whereas soil yielding is shown to provide a particularly effective energy dissipation mechanism, exhibiting significant resistance to cumulative damage. Thanks to such mechanisms, the rocking pier survived, with no signs of structural distress, a deleterious sequence of seismic motions that caused collapse of the conventionally designed pier. © 2014 The Authors Earthquake Engineering & Structural Dynamics Published by John Wiley & Sons Ltd. PMID:26300573

  1. Flow Analysis of the Cleveland Clinic Centrifugal Pump

    Science.gov (United States)

    Veres, Joseph P.; Golding, Leonard A. R.; Smith, William A.; Horvath, David; Medvedev, Alexander

    1997-01-01

    An implantable ventricular assist rotordynamic blood pump is being developed by the Cleveland Clinic Foundation in cooperation with the NASA Lewis Research Center. At the nominal design condition, the pump provides blood flow at the rate of 5 liters per minute at a pressure rise of 100 mm of mercury and a rotative speed of 3000 RPM. Bench testing of the centrifugal pump in a water/glycerin mixture has provided flow and pressure data at several rotative speeds. A one-dimensional empirical based pump flow analysis computer code developed at NASA Lewis Research Center has been used in the design process to simulate the flow in the primary centrifugal pump stage. The computer model was used to size key impeller and volute geometric parameters that influence pressure rise and flow. Input requirements to the computer model include a simple representation of the pump geometry. The model estimates the flow conditions at the design and at off-design operating conditions at the impeller leading and trailing edges and the volute inlet and exit. The output from the computer model is compared to flow and pressure data obtained from bench testing.

  2. Design Attributes and Scale Up Testing of Annular Centrifugal Contactors

    Energy Technology Data Exchange (ETDEWEB)

    David H. Meikrantz; Jack D. Law

    2005-04-01

    Annular centrifugal contactors are being used for rapid yet efficient liquid- liquid processing in numerous industrial and government applications. Commercialization of this technology began eleven years ago and now units with throughputs ranging from 0.25 to 700 liters per minute are readily available. Separation, washing, and extraction processes all benefit from the use of this relatively new commercial tool. Processing advantages of this technology include: low in-process volume per stage, rapid mixing and separation in a single unit, connection-in-series for multi-stage use, and a wide operating range of input flow rates and phase ratios without adjustment. Recent design enhancements have been added to simplify maintenance, improve inspection ability, and provide increased reliability. Cartridge-style bearing and mechanical rotary seal assemblies that can include liquid-leak sensors are employed to enhance remote operations, minimize maintenance downtime, prevent equipment damage, and extend service life. Clean-in-place capability eliminates the need for disassembly, facilitates the use of contactors for feed clarification, and can be automated for continuous operation. In nuclear fuel cycle studies, aqueous based separations are being developed that efficiently partition uranium, actinides, and fission products via liquid-liquid solvent extraction. Thus, annular centrifugal contactors are destined to play a significant role in the design of such new processes. Laboratory scale studies using mini-contactors have demonstrated feasibility for many such separation processes but validation at an engineering scale is needed to support actual process design.

  3. Methodology for optimally sized centrifugal partition chromatography columns.

    Science.gov (United States)

    Chollet, Sébastien; Marchal, Luc; Jérémy Meucci; Renault, Jean-Hugues; Legrand, Jack; Foucault, Alain

    2015-04-01

    Centrifugal Partition Chromatography (CPC) is a separation process based on the partitioning of solutes between two partially miscible liquid phases. There is no solid support for the stationary phase. The centrifugal acceleration is responsible for both stationary phase retention and mobile phase dispersion. CPC is thus a process based on liquid-liquid mass transfer. The separation efficiency is mainly influenced by the hydrodynamics of the phases in each cell of the column. Thanks to a visualization system, called "Visual CPC", it was observed that the mobile phase can flow through the stationary phase as a sheet, or a spray. Hydrodynamics, which directly governs the instrument efficiency, is directly affected during scale changes, and non-linear phenomena prevent the successful achievement of mastered geometrical scale changes. In this work, a methodology for CPC column sizing is proposed, based on the characterization of the efficiency of advanced cell shapes, taking into account the hydrodynamics. Knowledge about relationship between stationary phase volume, cell efficiency and separation resolution in CPC allowed calculating the optimum cell number for laboratory and industrial scale CPC application. The methodology is highlighted with results on five different geometries from 25 to 5000 mL, for two applications: the separation of alkylbenzene by partitioning with heptane/methanol/water biphasic system; and the separation of peptides by partitioning with n-butanol/acetic acid/water (4/1/5) biphasic system. With this approach, it is possible to predict the optimal CPC column length leading to highest productivity.

  4. Cardio-postural interactions and short-arm centrifugation.

    Science.gov (United States)

    Blaber, Andrew; Goswami, Nandu; Xu, Da; Laurin, Alexendre

    INTRODUCTION: We are interested in mechanisms associated with orthostatic tolerance. In previous studies we have shown that postural muscles in the calf contribute to both posture and blood pressure regulation during orthostatic stress. In this study we investigated the relationship between cardiovascular and postural muscle control before, during and after short arm human centrifuge (SAHC) up to 2.2 G. METHODS: Eleven healthy young subjects (6 m, 5 f), with no history of cardiovascular disease, falls or orthostatic hypotension, participated. All were familiarized with the SAHC with 10 minutes at 1-G at the feet. Each subject was instrumented in the supine position on the SAHC for beat-to-beat ECG and blood pressure (Portapres derived SBP). Bilateral lower leg EMG was collected from four leg postural muscles: tibialis anterior, medial gastrocnemius, lateral gastrocnemius, and medial soleus. Transdermal differential recording of signals was performed using an 8-channel EMG system, (Myosystem 1200, Noraxon Inc., Arizona, USA). Postural sway data of the body COP was computed from the force and moment data collected with a force platform (Accusway, AMTI, MA, USA). Before and after SAHC, the subject stood on a force platform with their gaze fixed on a point at eye level, closed their eyes and stood quietly for 5 min. A final stand was conducted 30 min after centrifugation with supine rest in between. During clockwise centrifugation (10-min 1g and 10-min 2.2g at the foot) the subjects’ head was hooded and in the dark. The subject’s body was restrained into the rotation arm with a parachute harness and given additional body support with a foot-plate. ECG, EMG and BP data were collected throughout and centre of pressure trajectory (COP) collected during the stand test. Subjects were requested to relax and not to voluntarily contract the leg muscles; however, they were not to suppress contractions as they occurred involuntarily or by reflex. A Continuous Wavelet

  5. The determination of phenazone in blood plasma for obtained sistem suitable test of monitoring drug level

    OpenAIRE

    Mochamad Lazuardi

    2007-01-01

    The determining of Phenazone to human blood plasma from healthy man after separated by solid phase extraction (SPE) and spectroscopic measurements has been investigated. The objective of that research was to obtain system suitable test for determine the Phenazone level in biological fluids (human blood plasma), for new performed dosage regimented in clinical dentistry. The method can be divided into the following four steps. 1. Centrifugation the blood sample, 2. Extraction from blood plasma ...

  6. Determination of Some Biochemical Parameters in the Seminal Plasma of German Shepherd Dogs

    OpenAIRE

    GÜNAY, Ülgen

    2003-01-01

    In this study, we aimed to determine the levels of some biochemical parameters in the seminal plasma of German Shepherd dogs. Seven German Shepherd dogs were used as materials. A total of 35 ejaculates, five from each dog, were collected. The seminal plasma of each ejaculate was separated by centrifugation at 5000 rpm for 10 min. Biochemical analyses of the seminal plasma were performed. In conclusion, the average concentrations of total protein, calcium, phosphorus, magnesium, sodium and pot...

  7. In vitro evaluation of the TandemHeart pediatric centrifugal pump.

    Science.gov (United States)

    Svitek, Robert G; Smith, Douglas E; Magovern, James A

    2007-01-01

    The pediatric TandemHeart pump is being developed for short-term circulatory support of patients varying in size from 2 to 40 kg. The pump withdraws blood from the left atrium via cannula inserted percutaneously, either through the right internal jugular vein or transhepatically, and pumps the blood back into the arterial system via the carotid or femoral artery. High resolution stereolithography (SLA) was used to create an upper housing and impeller design, which were assembled into a functional pump prototype. Pressure-flow characteristics of the pump were determined in a blood analogue solution and compared with the pressure-flow requirements of the intended cannulation. At 5,500 rpm, the pump was able to generate 0.4 L/min of flow with a pressure rise of 325 mm Hg and 2.0 L/min with a pressure rise of 250 mm Hg. The hydraulic performance of the pump will enable at least 50% of cardiac output when the arterial cannula is placed in the carotid artery. The hemolysis of the TandemHeart pediatric pump at 5,500 rpm was compared with the BP-50 pediatric centrifugal pump in vitro using bovine blood flowing at 0.4 L/min against 250 mm Hg. The TandemHeart pump produced a similar increase in plasma free hemoglobin levels during the duration of the 6 hour test.

  8. Plasma turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Horton, W. [Univ. of Texas, Austin, TX (United States). Inst. for Fusion Studies; Hu, G. [Globalstar LP, San Jose, CA (United States)

    1998-07-01

    The origin of plasma turbulence from currents and spatial gradients in plasmas is described and shown to lead to the dominant transport mechanism in many plasma regimes. A wide variety of turbulent transport mechanism exists in plasmas. In this survey the authors summarize some of the universally observed plasma transport rates.

  9. Incidence of electrocardiographic changes during cytapheresis using an intermittent flow centrifuge, haemonetics V50 and a continuous flow centrifuge, AS104.

    Science.gov (United States)

    Komatsu, F; Kajiwara, M

    1997-03-01

    Electrocardiographic (ECG) monitoring was performed during cytapheresis and the incidence of ECG changes was compared between methods of intermittent flow centrifugation using the Haemonetics V50 with apheresis donors and continuous flow centrifugation with the AS104 for peripheral blood stem cell (PBSC) collection from patients. ST depression, inverted T wave and other ECG changes were found in 49 (14.3%) of the 342 cytaphereses carried out by the intermittent flow centrifugation method and in 8 (4.7%) of the 169 PBSC collections by the continuous flow centrifugation method. This difference was significant (P < 0.05). The hemodynamic changes in the procedure with the AS104 seem to be small. This is considered to be important for prevention of serious ST and T wave changes.

  10. Thermonuclear dynamo inside ultracentrifuge with supersonic plasma flow stabilization

    Energy Technology Data Exchange (ETDEWEB)

    Winterberg, F. [University of Nevada, Reno, Reno, Nevada (United States)

    2016-01-15

    Einstein's general theory of relativity implies the existence of virtual negative masses in the rotational reference frame of an ultracentrifuge with the negative mass density of the same order of magnitude as the positive mass density of a neutron star. In an ultracentrifuge, the repulsive gravitational field of this negative mass can simulate the attractive positive mass of a mini-neutron star, and for this reason can radially confine a dense thermonuclear plasma placed inside the centrifuge, very much as the positive mass of a star confines its plasma by its own attractive gravitational field. If the centrifuge is placed in an externally magnetic field to act as the seed field of a magnetohydrodynamic generator, the configuration resembles a magnetar driven by the release of energy through nuclear fusion, accelerating the plasma to supersonic velocities, with the magnetic field produced by the thermomagnetic Nernst effect insulating the hot plasma from the cold wall of the centrifuge. Because of the supersonic flow and the high plasma density the configuration is stable.

  11. The enhanced pellet centrifuge launcher at ASDEX Upgrade: Advanced operation and application as technology test facility for ITER and DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Ploeckl, B., E-mail: bernhard.ploeckl@ipp.mpg.de [Max Planck Institute for Plasma Physics, EURATOM Association, Boltzmannstr. 2, 85748 Garching (Germany); Day, Chr. [Karlsruhe Institute of Technology (KIT), 76021 Karlsruhe (Germany); Lamalle, Ph. [ITER Organization, Route de Vinon sur Verdon, CS 90046, 13067 Saint-Paul-lez-Durance (France); Lang, P.T.; Rohde, V.; Viezzer, E. [Max Planck Institute for Plasma Physics, EURATOM Association, Boltzmannstr. 2, 85748 Garching (Germany)

    2015-10-15

    The pellet centrifuge at ASDEX Upgrade has served for more than 20 years as a powerful tool for plasma control. Its recently enhanced control system provides more thorough control over parameters and a detailed view of all measured values. A study has recently been initiated on the conceptual design of an optimized DEMO core particle fuelling system. For this approach, first technical tests aimed on an optimized pellet transfer with respect to the preparation of the solid fuel and the transfer systems have been performed. An investigation of the temperature dependence of transfer efficiency (mass loss due to erosion and broken pellets) has revealed a weak dependence. For ITER, in which it is intended to operate a heating scheme with ICRF minority heating of He-3, test injections are performed using D{sub 2}-pellets as carriers for He-4. Admixing of N{sub 2} was investigated as well.

  12. PECULIARITIES OF STRUCTURE-FORMATION AT SVS IN MELTED CONDENSED MIXTURES AT INFLUENCE OF CENTRIFUGAL FORCE

    Directory of Open Access Journals (Sweden)

    V. V. Hubovich

    2007-01-01

    Full Text Available The influence of centrifugal force on dynamics of the burning wave spread and the carbide particles distribution in metallic alloy in the process of SVS-casting is considered. It was concluded that centrifugal force can be used for production of materials with gradient of the hardening particles concentration.

  13. The theory of the centrifugal mechanism of feeding-in in bent crystals

    OpenAIRE

    2001-01-01

    For a particle channeled in the bent crystal planes (axes), the phenomenon of "bending dechanneling", which is a particle transition to a random state due to centrifugal force, is well known. We consider an analytical theory of the reverse phenomenon, i.e., feeding from a random state to a channeled state due to centrifugal force in a crystal with variable curvature.

  14. Centripetal/Centrifugal Family Style of Families with Aggressive and Non-Aggressive Boys.

    Science.gov (United States)

    Hurst, Duane F.; And Others

    Research on family interaction has characterized family style on centripetal and centrifugal dimensions, representing opposing natures with their own continua. Centripetal forces produce binding, or a prolonged process of separation of parent and child; centrifugal forces preciptate expelling, or hastened separation and premature autonomy. To…

  15. Numerical Calculation of the Three-Dimensional Swirling Flow Inside the Centrifugal Pump Volutes

    Directory of Open Access Journals (Sweden)

    E. Cezmi Nursen

    2003-01-01

    Full Text Available The flow inside the volute of a centrifugal pump is threedimensional and, depending upon the position of the inlet relative to the cross-section center line, a single or double swirling flow occurs. The purpose of this study was the calculation of the three-dimensional swirling flow inside the centrifugal pump volute.

  16. THEORETICAL FLOW MODEL THROUGH A CENTRIFUGAL PUMP USED FOR WATER SUPPLY IN AGRICULTURE IRRIGATION

    Directory of Open Access Journals (Sweden)

    SCHEAUA Fanel Dorel

    2017-05-01

    motion of the rotor. A theoretical model for calculating the flow of the working fluid through the interior of a centrifugal pump model is presented in this paper as well as the numerical analysis on the virtual model performed with the ANSYS CFX software in order to highlight the flow parameters and flow path-lines that are formed during centrifugal pump operation.

  17. Effect of Al-5Ti-B Inoculant Addition on the Graded Microstructure of Centrifugally Cast Al-13.8 wt.% Mg2Si Composite

    Directory of Open Access Journals (Sweden)

    A. Samadi

    2015-07-01

    Full Text Available To evaluate the effect of inoculant addition on functionally graded microstructure of centrifugally cast Al-Mg2Si composites, two cylinders of Al-13.8 wt.% Mg2Si with and without the addition of 1 wt.% Al-5Ti-B inoculant were cast in a vertical centrifugal casting machine. The chemical composition, microstructures and microstructural phases of the different radial sections of the cast cylinders were studied using induction coupled plasma (ICP method, optical/scanning electron microscopes, and X-ray diffractometry, respectively. The results showed that in the inoculant content cylinder, owing to the prevailing thermal regime as well as the specific mode of eutectic solidification in this composite, the titanium and boron compounds were segregated towards the middle layer of the cylinder and caused the formation of primary Mg2Si particles and non-eutectic Al ( in this layer. In addition, due to the effect of centrifugal force during solidification, a higher volume fraction of the light primary Mg2Si particles, according to Stocks law, was segregated towards the inner layer of the cast cylinders.

  18. Preclinical study of a novel hydrodynamically levitated centrifugal pump for long-term cardiopulmonary support : In vivo performance during percutaneous cardiopulmonary support.

    Science.gov (United States)

    Tsukiya, Tomonori; Mizuno, Toshihide; Takewa, Yoshiaki; Tatsumi, Eisuke; Taenaka, Yoshiyuki

    2015-12-01

    An extracorporeal centrifugal blood pump with a hydrodynamically levitated impeller was developed for use in a durable extracorporeal membrane oxygenation (ECMO) system. The present study examined the biocompatibility of the blood pump during long-term use by conducting a series of 30-day chronic animal experiments. The ECMO system was used to produce a percutaneous venoarterial bypass between the venae cavae and carotid artery in adult goats. No anticoagulation or antiplatelet therapy was administered during the experiments. Three out of four animals survived for the scheduled 30-day period, and the blood pumps and membrane oxygenators both exhibited sufficient hydrodynamic performance and good antithrombogenicity, while one animal died of massive bleeding from the outflow cannulation site. The animals' plasma free hemoglobin had returned to within the normal range by 1 week after the surgical intervention, and their hemodynamic and biochemistry parameters remained within their normal ranges throughout the experiment. The explanted centrifugal blood pumps did not display any trace of thrombus formation. Based on the biocompatibility demonstrated in this study, the examined centrifugal blood pump, which includes a hydrodynamically levitated impeller, is suitable for use in durable ECMO systems.

  19. High Technology Centrifugal Compressor for Commercial Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ruckes, John

    2006-04-15

    R&D Dynamics, Bloomfield, CT in partnership with the State of Connecticut has been developing a high technology, oil-free, energy-efficient centrifugal compressor called CENVA for commercial air conditioning systems under a program funded by the US Department of Energy. The CENVA compressor applies the foil bearing technology used in all modern aircraft, civil and military, air conditioning systems. The CENVA compressor will enhance the efficiency of water and air cooled chillers, packaged roof top units, and other air conditioning systems by providing an 18% reduction in energy consumption in the unit capacity range of 25 to 350 tons of refrigeration The technical approach for CENVA involved the design and development of a high-speed, oil-free foil gas bearing-supported two-stage centrifugal compressor, CENVA encompassed the following high technologies, which are not currently utilized in commercial air conditioning systems: Foil gas bearings operating in HFC-134a; Efficient centrifugal impellers and diffusers; High speed motors and drives; and System integration of above technologies. Extensive design, development and testing efforts were carried out. Significant accomplishments achieved under this program are: (1) A total of 26 builds and over 200 tests were successfully completed with successively improved designs; (2) Use of foil gas bearings in refrigerant R134a was successfully proven; (3) A high speed, high power permanent magnet motor was developed; (4) An encoder was used for signal feedback between motor and controller. Due to temperature limitations of the encoder, the compressor could not operate at higher speed and in turn at higher pressure. In order to alleviate this problem a unique sensorless controller was developed; (5) This controller has successfully been tested as stand alone; however, it has not yet been integrated and tested as a system; (6) The compressor successfully operated at water cooled condensing temperatures Due to temperature

  20. Concept designs of nonrotating-type centrifugal blood pump and basic study on output characteristics of the oscillating disk-type centrifugal pump.

    Science.gov (United States)

    Kabei, N; Tuichiya, K; Sakurai, Y

    1994-09-01

    When designing a turbo-type blood pump as an artificial heart, the gap between a rotating shaft and a pump housing should be perfectly sealed to prevent any leakage or contamination through a seal. In addition, blood coagulation in a blood chamber must be avoided. To overcome these problems, we proposed five different nonrotating-type turbo pumps: a caudal-fin-type axial-flow pump, a caudal-fin-type centrifugal pump, a nutating-column-type centrifugal pump, a nutating-collapsible-tube-type centrifugal pump, and an oscillating-disk-type centrifugal pump. We selected and developed the oscillating-disk-type centrifugal pump that consists of a disk, a driving rod, a seal, an oscillation mechanism, and a pump housing. The disk is mounted on the end of the rod, which is connected to a high-speed DC motor through an oscillation mechanism. The rod and the disk do not rotate, but they oscillate in the pump housing. This movement of the disk generates forward fluid flow around the axis (i.e., the rotational fluid flow). Centrifugal force due to fluid rotation supports the pressure difference between the outlet and the inlet. The diameter of the disk is 39 mm, the maximum inner diameter of the pump housing is 40 mm, and the volume of the blood chamber for 25 degrees' oscillation is 16.9 ml. The performance of the pump was tested in a mock circulatory system.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. The potential of centrifugal casting for the production of near net shape uranium parts

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, E. [United States Air Force Academy, Colorado Springs, CO (US). Dept. of Engineering Mechanics

    1993-09-01

    This report was written to provide a detailed summary of a literature survey on the near net shape casting process of centrifugal casting. Centrifugal casting is one potential casting method which could satisfy the requirements of the LANL program titled Near Net Shape Casting of Uranium for Reduced Environmental, Safety and Health Impact. In this report, centrifugal casting techniques are reviewed and an assessment of the ability to achieve the near net shape and waste minimization goals of the LANL program by using these techniques is made. Based upon the literature reviewed, it is concluded that if properly modified for operation within a vacuum, vertical or horizontal centrifugation could be used to safely cast uranium for the production of hollow, cylindrical parts. However, for the production of components of geometries other than hollow tubes, vertical centrifugation could be combined with other casting methods such as semi-permanent mold or investment casting.

  2. Plasma harmonics

    CERN Document Server

    Ganeev, Rashid A

    2014-01-01

    Preface; Why plasma harmonics? A very brief introduction Early stage of plasma harmonic studies - hopes and frustrations New developments in plasma harmonics studies: first successes Improvements of plasma harmonics; Theoretical basics of plasma harmonics; Basics of HHG Harmonic generation in fullerenes using few-cycle pulsesVarious approaches for description of observed peculiarities of resonant enhancement of a single harmonic in laser plasmaTwo-colour pump resonance-induced enhancement of odd and even harmonics from a tin plasmaCalculations of single harmonic generation from Mn plasma;Low-o

  3. Use of partially shrouded impeller in a small centrifugal compressor

    Institute of Scientific and Technical Information of China (English)

    Jin Tang; Teemu Turunen-Saaresti; Jaakko Larjola

    2008-01-01

    Numerical analysis is conducted for the 3-dimensional impeller and vaneless diffuser of a small centrifugal compressor. The influence of impeller tip clearance on the flow field of the impeller is investigated. Detailed investigation on the leaking flow across the tip clearance of the impeller shows that the leaking flow rate is higher near the exit of the impeller than that near the inlet of the impeller. Based on this phenomenon, a new partially shrouded impeller is designed. The impeller is shrouded near the exit of the impeller. Numerical results show that the secondary flow region becomes smaller at the exit of the impeller. Better performance is achieved than that with the unshrouded impeller.

  4. Numerical study of a high-speed miniature centrifugal compressor

    Science.gov (United States)

    Li, Xiaoyi

    A miniature centrifugal compressor is a key component of reverse Brayton cycle cryogenic cooling system. The system is commonly used to generate a low cryogenic temperature environment for electronics to increase their efficiency, or generate, store and transport cryogenic liquids, such as liquid hydrogen and oxygen, where space limit is also an issue. Because of space limitation, the compressor is composed of a radial IGV, a radial impeller and an axial-direction diffuser (which reduces the radial size because of smaller diameter). As a result of reduction in size, rotating speed of the impeller is as high as 313,000 rpm, and Helium is used as the working fluid, in order to obtain the required static pressure ratio/rise. Two main characteristics of the compressor---miniature and high-speed, make it distinct from conventional compressors. Higher compressor efficiency is required to obtain a higher COP (coefficient of performance) system. Even though miniature centrifugal compressors start to draw researchers' attention in recent years, understanding of the performance and loss mechanism is still lacking. Since current experimental techniques are not advanced enough to capture details of flow at miniature scale, numerical methods dominate miniature turbomachinery study. This work numerically studied a high speed miniature centrifugal compressor with commercial CFD code. The overall performance of the compressor was predicted with consideration of interaction between blade rows by using sliding mesh model. The law of similarity of turbomachinery was validated for small scale machines. It was found that the specific ratio effect needs to be considered when similarity law is applied. But Reynolds number effect can be neglected. The loss mechanism of each component was analyzed. Loss due to turning bend was significant in each component. Tip leakage loss of small scale turbomachines has more impact on the impeller performance than that of large scale ones. Because the

  5. A cryogenic axial-centrifugal compressor for superfluid helium refrigeration

    CERN Document Server

    Decker, L; Schustr, P; Vins, M; Brunovsky, I; Lebrun, P; Tavian, L

    1997-01-01

    CERN's new project, the Large Hadron Collider (LHC), will use superfluid helium as coolant for its high-field superconducting magnets and therefore require large capacity refrigeration at 1.8 K. This may only be achieved by subatmospheric compression of gaseous helium at cryogenic temperature. To stimulate development of this technology, CERN has procured from industry prototype Cold Compressor Units (CCU). This unit is based on a cryogenic axial-centrifugal compressor, running on ceramic ball bearings and driven by a variable-frequency electrical motor operating under low-pressure helium at ambient temperature. The machine has been commissioned and is now in operation. After describing basic constructional features of the compressor, we report on measured performance.

  6. Approaches to Stable Operation of Shaftless Centrifugal Pump

    Institute of Scientific and Technical Information of China (English)

    Ryunosuke Kawashima; Mitsuo Uno; Toshiaki Kanemoto

    2009-01-01

    The shaft-less impeller of the centrifugal pump, which is driven by the magnetic induction, was developed. The impeller rotates under the floating condition without any control device. The floating condition of the impeller is realized by utilizing the pressure in pump casing. The pump performance and the rotational behavior of the im-peUer were investigated experimentally. It has found that the floating position of the impeller become quite unsta-ble in a partial flow rate operation. And the pressure distribution at the casing wall affects the rotational posture of the impeller. This paper presents the effect of the casing treatment on the rotational posture of the impeller and the pressure distribution. The reasonable casing treatment is available for the stable rotational posture of the impeller.

  7. A multiple disk centrifugal pump as a blood flow device.

    Science.gov (United States)

    Miller, G E; Etter, B D; Dorsi, J M

    1990-02-01

    A multiple disk, shear force, valveless centrifugal pump was studied to determine its suitability as a blood flow device. A pulsatile version of the Tesla viscous flow turbine was designed by modifying the original steady flow pump concept to produce physiological pressures and flows with the aid of controlling circuitry. Pressures and flows from this pump were compared to a Harvard Apparatus pulsatile piston pump. Both pumps were connected to an artificial circulatory system. Frequency and systolic duration were varied over a range of physiological conditions for both pumps. The results indicated that the Tesla pump, operating in a pulsatile mode, is capable of producing physiologic pressures and flows similar to the Harvard pump and other pulsatile blood pumps.

  8. Performance Improvement of a Centrifugal Compressor by Passive Means

    Directory of Open Access Journals (Sweden)

    N. Sitaram

    2012-01-01

    Full Text Available The present experimental investigation deals with performance improvement of a low-speed centrifugal compressor by inexpensive passive means such as turbulence generator placed at different positions and partial shroud near the rotor blade tip. The experiments are carried out at three values of tip clearance, namely 2.2%, 5.1%, and 7.9% of rotor blade height at the exit. Performance tests are carried out for a total of 13 configurations. From these measurements, partial shroud is found to give the best performance. The improvement in the compressor performance may be due to the reduction of tip leakage flows by the small extension of partial shroud (2 mm on the pressure surface side. Although there is nominal change in performance due to turbulence generator (TG, TG has beneficial effect of increased operating range.

  9. Application of IMHOFLOT G-cell centrifugal flotation technology

    Energy Technology Data Exchange (ETDEWEB)

    Imhof, R.; Fletcher, M.; Vathavooran, A.; Singh, A. [Maelgwyn Mining Services Ltd., Cardiff (United Kingdom)

    2007-10-15

    The Imhoflot G-Cell, a new development in the pneumatic flotation technology (which incorporates centrifugal forces in the separating vessel), is a recent innovation in the mineral processing world. The G-Cell was invented by Dr Rainer Imhof and commercialized by Maelgwyn Mineral Services Ltd. In a short time span a number of plants and units have been successfully commissioned in the mineral processing industry. In addition, a number of industrial G-Cell flotation plants are in the process of construction for the purpose of coal preparation and environmental remediation. In this paper two industrial installations have been highlighted, together with a pilot plant test programme investigating ultra-fine flotation recovery for a base metal operation.

  10. Ultrasound treatment of centrifugally atomized 316 stainless steel powders

    Science.gov (United States)

    Rawers, James C.; McCune, Robert A.; Dunning, John S.

    1991-12-01

    The Bureau of Mines is studying the surface characteristics of rapidly solidified powders and the potential for surface modification of fine powders prior to consolidation. The surface modification and work hardening of fine powders were accomplished by applying high-energy ultrasound to centrifugally atomized austenitic 316 stainless steel powders suspended in liquid media. Cavitation implosion changed the surface morphology, hammering the surface and occasionally fretting off microchips of work-hardened metal. Ultrasound-cavitation work-hardened metal powder surfaces producing a strained, duplex austenite face-centered cubic (fcc)-martensite body-centered tetragonal (bct) phase structure. The amount of work hardening depended upon the quantity of ultrasound energy used, considering both power level and experimental time. Work hardening was relatively independent of the liquid media used.

  11. Effect of Bearing Housings on Centrifugal Pump Rotor Dynamics

    Science.gov (United States)

    Yashchenko, A. S.; Rudenko, A. A.; Simonovskiy, V. I.; Kozlov, O. M.

    2017-08-01

    The article deals with the effect of a bearing housing on rotor dynamics of a barrel casing centrifugal boiler feed pump rotor. The calculation of the rotor model including the bearing housing has been performed by the method of initial parameters. The calculation of a rotor solid model including the bearing housing has been performed by the finite element method. Results of both calculations highlight the need to add bearing housings into dynamic analyses of the pump rotor. The calculation performed by modern software packages is more a time-taking process, at the same time it is a preferred one due to a graphic editor that is employed for creating a numerical model. When it is necessary to view many variants of design parameters, programs for beam modeling should be used.

  12. Effect of Fluid Viscosity on Centrifugal Pump Performance

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Nohhyeong [GS Caltex Corporation, Daejeon (Korea, Republic of)

    2013-06-15

    The characteristics of centrifugal pump performance according to fluid viscosity change were studied experimentally. A small volute pump with low specific speed was tested by changing the viscosity of an aqueous solution of sugar and glycerin, which is considered a Newtonian fluid. After finishing the test, the total head, shaft horsepower, and pump efficiency were compared with those of a water pump. The results are summarized as follows: when the fluid viscosity is increased, the shut-off head shows very little change but the total head decreases gradually as the flow increases, and this makes the H-Q curve leaning rapidly, and when the fluid viscosity is increased, the shaft horsepower shows very little change at the shutoff condition; however, the shaft horsepower increases more rapidly with an increase in the flow and viscosity.

  13. Tin-Copper-Lead Alloy Produced by Horizontal Centrifugal Casting

    Directory of Open Access Journals (Sweden)

    Vahdat S.E.

    2016-03-01

    Full Text Available Horizontal centrifugal casting is an effective method for the production of hollow metal with good mechanical properties, low defect, cast to size and relatively cheap. The ability of a metal to satisfy the above requirements highly depends on its microstructure. In this study, the relationship between microstructural parameters such as grain size and the amount of phases with bulk hardness of SnCu4Pb3 is concerned in three areas of the product. Consequently, to achieve the desired hardness of the product in a particular area, the interaction of two factors of the microstructure including, grain size and particles amount of the hard intermetallic compositions (Cu6Sn5 should be noted.

  14. Centrifugal experimental study of suction bucket foundations under dynamic loading

    Institute of Scientific and Technical Information of China (English)

    Xiaobing Lu; Yongren Wu; Bintian Jiao; Shuyun Wang

    2007-01-01

    Centrifugal experiments were carded out to investigate the responses of suction bucket foundations under horizontal and vertical dynamic loading. It is shown that when the loading amplitude is over a critical value, the sand at the upper part around the bucket is softened or even liq-uefied. The excess pore pressure decreases from the upper part to the lower part of the sand layer in the vertical direc-tion and decreases radially from the bucket's side wall in the horizontal direction. Large settlements of the bucket and the sand layer around the bucket are induced by dynamic load-ing. The dynamic responses of the bucket with smaller height (the same diameter) are heavier.

  15. Systems approach used in the Gas Centrifuge Enrichment Plant

    Energy Technology Data Exchange (ETDEWEB)

    Rooks, W.A. Jr.

    1982-01-01

    A requirement exists for effective and efficient transfer of technical knowledge from the design engineering team to the production work force. Performance-Based Training (PBT) is a systematic approach to the design, development, and implementation of technical training. This approach has been successfully used by the US Armed Forces, industry, and other organizations. The advantages of the PBT approach are: cost-effectiveness (lowest life-cycle training cost), learning effectiveness, reduced implementation time, and ease of administration. The PBT process comprises five distinctive and rigorous phases: Analysis of Job Performance, Design of Instructional Strategy, Development of Training Materials and Instructional Media, Validation of Materials and Media, and Implementation of the Instructional Program. Examples from the Gas Centrifuge Enrichment Plant (GCEP) are used to illustrate the application of PBT.

  16. Operational Experience with a Cryogenic Axial-Centrifugal Compressor

    CERN Document Server

    Decker, L; Löhlein, K; Purtschert, W; Ziegler, B L; Lebrun, P; Tavian, L; Brunovsky, I; Tucek, L

    1998-01-01

    The Large Hadron Collider (LHC), presently under construction at CERN, requires large refrigeration capacity at 1.8 K. Compression of gaseous helium at cryogenic temperatures is therefore inevitable. Together with subcontractors, Linde Kryotechnik has developed a prototype machine. This unit is based on a cryogenic axial-centrifugal compressor, running on ceramic ball bearings and driven by a variable-frequency electrical motor operating at ambient temperature. Integrated in a test facility for superconducting magnets the machine has been commissioned without major problems and successfully gone through the acceptance test in autumn 1995. Subsequent steps were initiated to improve efficiency of this prototype. This paper describes operating experience gained so far and reports on measured performance prior to and after constructional modifications.

  17. Centrifugal photovoltaic and photogalvanic effects driven by structured light

    CERN Document Server

    Wätzel, Jonas

    2016-01-01

    Much efforts are devoted to material structuring in a quest to enhance the photovoltaic effect. We show that structuring light in a way it transfers orbital angular momentum to semiconductor-based rings results in a steady charge accumulation at the outer boundaries that be utilized for the generation of an open circuit voltage or a photogalvanic (bulk photovoltaic) type current. This effect which stems both from structuring light and matter (confinement potentials), can be magnified even at fixed moderate intensities, by increasing the orbital angular momentum of light which strengthens the effective centrifugal potential that repels the charge outwards. Based on a full numerical time propagation of the carriers wave functions in the presence of light pulses we demonstrate how the charge buildup leads to a useable voltage or directed photocurrent whose amplitudes and directions are controllable by the light pulse parameters.

  18. Processing emulsions from desalting of crude oil using centrifuges

    Energy Technology Data Exchange (ETDEWEB)

    Steiger, W.; Westenthanner, F.; Reichl, J. [Flottweg GmbH und Co. KGaA, Vilsbiburg (Germany)

    2006-12-15

    Crude oil directly from the well contains brine. This brine is separated using static settling in tanks. Thereby a layer of emulsion is built up in the interface between oil and the brine, which reduces the available tank volume and makes the separation process difficult. In order to break the emulsion there are several approaches, e.g., use of emulsion breaker, treatment using electrical field, ultra sonic, microwave, etc., This article describes a successful commissioning of a centrifuge, a FLOTTWEG, TRICANTER {sup registered}, in the ural-central region. The FLOTTWEG TRICANTER {sup registered} enables a continuous 3-phase-separation, i. e., separation of the emulsion into oil, water and solids without chemical additives. (orig.)

  19. Stopping intense beams of internally cold molecules via centrifugal forces

    Science.gov (United States)

    Wu, Xing; Gantner, Thomas; Zeppenfeld, Martin; Chervenkov, Sotir; Rempe, Gerhard

    2016-05-01

    Cryogenic buffer-gas cooling produces intense beams of internally cold molecules. It offers a versatile source for studying collision dynamics and reaction pathways in the cold regime, and could open new avenues for controlled chemistry, precision spectroscopy, and exploration of fundamental physics. However, an efficient deceleration of these beams still presents a challenge. Here, we demonstrate that intense and continuous beams of electrically guided molecules produced by a cryogenic buffer-gas cell can be brought to a halt by the centrifugal force in a rotating frame. Various molecules (e.g. CH3F and CF3CCH) are decelerated to below 20m /s at a corresponding output intensity of ~ 6 ×109mm-2 .s-1 . In addition, our RF-resonant depletion detection shows that up to 90 % rotational-state purity can be achieved in the so-produced slow molecular beams.

  20. Approaches to stable operation of shaftless centrifugal pump

    Science.gov (United States)

    Kawashima, Ryunosuke; Uno, Mitsuo; Kanemoto, Toshiaki

    2009-03-01

    The shaft-less impeller of the centrifugal pump, which is driven by the magnetic induction, was developed. The impeller rotates under the floating condition without any control device. The floating condition of the impeller is realized by utilizing the pressure in pump casing. The pump performance and the rotational behavior of the impeller were investigated experimentally. It has found that the floating position of the impeller become quite unstable in a partial flow rate operation. And the pressure distribution at the casing wall affects the rotational posture of the impeller. This paper presents the effect of the casing treatment on the rotational posture of the impeller and the pressure distribution. The reasonable casing treatment is available for the stable rotational posture of the impeller.

  1. Centrifugal photovoltaic and photogalvanic effects driven by structured light.

    Science.gov (United States)

    Wätzel, J; Berakdar, J

    2016-02-22

    Much efforts are devoted to material structuring in a quest to enhance the photovoltaic effect. We show that structuring light in a way it transfers orbital angular momentum to semiconductor-based rings results in a steady charge accumulation at the outer boundaries that can be utilized for the generation of an open circuit voltage or a photogalvanic (bulk photovoltaic) type current. This effect which stems both from structuring light and matter confinement potentials, can be magnified even at fixed moderate intensities, by increasing the orbital angular momentum of light which strengthens the effective centrifugal potential that repels the charge outwards. Based on a full numerical time propagation of the carriers wave functions in the presence of light pulses we demonstrate how the charge buildup leads to a useable voltage or directed photocurrent whose amplitudes and directions are controllable by the light pulse parameters.

  2. A Novel Aerodynamic Design Method for Centrifugal Compressor Impeller

    Directory of Open Access Journals (Sweden)

    Mahdi Nili-Ahmadabadi

    2014-01-01

    Full Text Available This paper describes a new quasi-3D design method for centrifugal compressor impeller. The method links up a novel inverse design algorithm, called Ball-Spine Algorithm (BSA, and a quasi-3D analysis. Euler equation is solved on the impeller meridional plane. The unknown boundaries (hub and shroud of numerical domain are iteratively modified by BSA until a target pressure distribution in flow passage is reached. To validate the quasi-3D analysis code, existing compressor impeller is investigated experimentally. Comparison between the quasi-3D analysis and the experimental results shows good agreement. Also, a full 3D Navier-Stokes code is used to analyze the existing and designed compressor numerically. The results show that the momentum decrease near the shroud wall in the existing compressor is removed by hub-shroud modifications resulting an improvement in performance by 0.6 percent.

  3. DETECTION OF CAVITATION IN CENTRIFUGAL PUMP BY VIBRATION METHODS

    Institute of Scientific and Technical Information of China (English)

    NI Yongyan; YUAN Shouqi; PAN Zhongyong; YUAN Jianping

    2008-01-01

    For the purpose of detecting the cavitation of centrifugal pump onsite and real time, the vibration signals on varied operation conditions of both cavitation and non-cavitation obtained through acceleration sensors were analyzed. When cavitation occurs, the cavities near the leading edge of the blade will appear periodic oscillating, which will induce quasi-synchronous vibration. The frequency of the quasi-synchronous vibration symmetrically appears on the two sides of the blade passing frequency, by which the cavitation incipiency can be detected. During the developing process of the cavitation, as the severe complexity of the unsteady flow, it is very difficult to detect the development of cavitation by classical analysis methods. Fractal method of Higuchi is successfully used for detecting the incipiency, fully development of cavitation and the development between them.

  4. Flow Characteristics of a Pipe Diffuser for Centrifugal Compressors

    Directory of Open Access Journals (Sweden)

    Zhenzhong Sun

    2017-01-01

    Full Text Available The pipe diffuser, an efficient kind of radial bladed diffuser, is widely used in centrifugal compressors for gas turbine engines. This paper investigates flow characteristics of a pipe diffuser for centrifugal compressors by solving three-dimensional Reynolds-averaged Navier-Stokes equations. The results show that the pipe diffuser is adaptable to high Mach number incoming flows, and its unique leading edge could uniform the flow distortion. Numerical analysis indicates that the choke in pipe diffuser occurs suddenly, which leads to the dramatically steep performance curves near choke condition. Besides, it is found that the first half flow passage is particularly important to the pipe diffuser performance as it influences the choking behavior, the static pressure distribution, and the matching, so more attention should be paid to this region when designing or optimizing a pipe diffuser. Two counter-rotating vortices generated in the diffuser inlet region are captured by numerical simulation, and they can exist in the downstream of the diffuser passage. More detailed analysis show that these two vortices dominate the flow structure in the whole diffuser passage by shifting flow to certain positions and forming high-momentum flow cells and wake flow cells. The leading edge formed by the intersection of adjacent diffuser passages significantly affects this pair of vortices. In addition, these two vortices also affect the flow separation in pipe diffuser flow passages, they suppress separation near the front wall and back wall while facilitate separation at center locations. Therefore, it is recommended to design the leading edge of the pipe diffuser carefully to control the vortices and obtain a better flow field.

  5. Shunted Piezoelectric Vibration Damping Analysis Including Centrifugal Loading Effects

    Science.gov (United States)

    Min, James B.; Duffy, Kirsten P.; Provenza, Andrew J.

    2011-01-01

    Excessive vibration of turbomachinery blades causes high cycle fatigue problems which require damping treatments to mitigate vibration levels. One method is the use of piezoelectric materials as passive or active dampers. Based on the technical challenges and requirements learned from previous turbomachinery rotor blades research, an effort has been made to investigate the effectiveness of a shunted piezoelectric for the turbomachinery rotor blades vibration control, specifically for a condition with centrifugal rotation. While ample research has been performed on the use of a piezoelectric material with electric circuits to attempt to control the structural vibration damping, very little study has been done regarding rotational effects. The present study attempts to fill this void. Specifically, the objectives of this study are: (a) to create and analyze finite element models for harmonic forced response vibration analysis coupled with shunted piezoelectric circuits for engine blade operational conditions, (b) to validate the experimental test approaches with numerical results and vice versa, and (c) to establish a numerical modeling capability for vibration control using shunted piezoelectric circuits under rotation. Study has focused on a resonant damping control using shunted piezoelectric patches on plate specimens. Tests and analyses were performed for both non-spinning and spinning conditions. The finite element (FE) shunted piezoelectric circuit damping simulations were performed using the ANSYS Multiphysics code for the resistive and inductive circuit piezoelectric simulations of both conditions. The FE results showed a good correlation with experimental test results. Tests and analyses of shunted piezoelectric damping control, demonstrating with plate specimens, show a great potential to reduce blade vibrations under centrifugal loading.

  6. Approach to novel design of CO2 based centrifugal compressor

    Directory of Open Access Journals (Sweden)

    Kura Tomasz

    2016-01-01

    Full Text Available Even though turbomachinery design issues have been investigated almost since the beginning of engineering, its optimization process is still important. With the development of refrigeration devices and ORC based distributed generation facilities, a need for efficient and low-energy compressors and turbines became even more demanding. Such machines working with typical fluid, like air, are well described, but there is a room regarding the fluids like CO2, vapour of organic fluids, etc. The main objective of present studies is to propose a numerical model of the centrifugal compressor, with CO2 as the working fluid. Such unit may be a part of refrigeration cycle. Commonly, the scroll or piston compressors are used in such cases, however some discussed disadvantages show that the novel designs should be looked for. Properly designed centrifugal compressors can have higher efficiency than the presently used. Three dimensional analyses of proposed geometries were conducted – using a model including heat, mass and momentum conservation laws as well as ideal gas law. Verification of the proposed mesh and results was performed in the basis of values obtained using theoretical and empirical equations. With about 700 000 control volumes in the validated model, error of the results was no higher than 5%, with only about 1% in regards to the thermal parameters. Two design proposals were analysed, with performance maps as the main comparison factor. Apart from performance characteristics, the pressure and velocity fields were presented, showing the process of flow structure optimization. The main goal was to reduce negative effects of pressure and velocity gradients on the performance. Proposed precursory design might be a good starting point for further development of compressors. The results of numerical analysis were promising and shows the possibility of proposed design usage in practical applications, however to obtain deep understanding of the

  7. Rigorous buoyancy driven bubble mixing for centrifugal microfluidics.

    Science.gov (United States)

    Burger, S; Schulz, M; von Stetten, F; Zengerle, R; Paust, N

    2016-01-21

    We present batch-mode mixing for centrifugal microfluidics operated at fixed rotational frequency. Gas is generated by the disk integrated decomposition of hydrogen peroxide (H2O2) to liquid water (H2O) and gaseous oxygen (O2) and inserted into a mixing chamber. There, bubbles are formed that ascent through the liquid in the artificial gravity field and lead to drag flow. Additionaly, strong buoyancy causes deformation and rupture of the gas bubbles and induces strong mixing flows in the liquids. Buoyancy driven bubble mixing is quantitatively compared to shake mode mixing, mixing by reciprocation and vortex mixing. To determine mixing efficiencies in a meaningful way, the different mixers are employed for mixing of a lysis reagent and human whole blood. Subsequently, DNA is extracted from the lysate and the amount of DNA recovered is taken as a measure for mixing efficiency. Relative to standard vortex mixing, DNA extraction based on buoyancy driven bubble mixing resulted in yields of 92 ± 8% (100 s mixing time) and 100 ± 8% (600 s) at 130g centrifugal acceleration. Shake mode mixing yields 96 ± 11% and is thus equal to buoyancy driven bubble mixing. An advantage of buoyancy driven bubble mixing is that it can be operated at fixed rotational frequency, however. The additional costs of implementing buoyancy driven bubble mixing are low since both the activation liquid and the catalyst are very low cost and no external means are required in the processing device. Furthermore, buoyancy driven bubble mixing can easily be integrated in a monolithic manner and is compatible to scalable manufacturing technologies such as injection moulding or thermoforming. We consider buoyancy driven bubble mixing an excellent alternative to shake mode mixing, in particular if the processing device is not capable of providing fast changes of rotational frequency or if the low average rotational frequency is challenging for the other integrated fluidic operations.

  8. Carnosol purification. Scaling-up centrifugal partition chromatography separations.

    Science.gov (United States)

    Bouju, Elodie; Berthod, Alain; Faure, Karine

    2016-09-30

    This paper illustrates the application of a recently proposed protocol allowing the scale-up prediction on hydrostatic countercurrent chromatography columns (centrifugal partition chromatographs or CPC). A commercial extract of rosemary (Rosmarinus officinalis L.) was used as the starting material containing 0.48% of carnosol, an active pharmaceutical ingredient with great potential. After a rapid method development on a small-scale 35-mL CPC instrument that allowed for the determination of the solvent system and maximum sample concentration and volume, the purification was transferred on two larger instruments using the "free space between peaks" method. The method takes into account the technical limitations of the larger instruments, such as pressure and/or maximum centrifugal field, and allows, by simply running an analytical-sized injection on the large scale rotor, to give an accurate prediction of the maximum sample load and best throughput. The 0.27g of rosemary extract maximum load on a 35-mL CPC was transferred as a 1.9g load on a 254-mL medium size CPC and 9g load on a 812-mL CPC. The maximum process efficiency of 3.1mg of carnosol per hour obtained on the small 35-mL column was transferred on the 254-mL CPC giving 8.3mg/h and, on the larger 812-mL column 49.4mg of carnosol could be obtained per hour. If the scaling-up in CPC instruments is not directly homothetic, it can be highly predictable through a few simple experiments.

  9. A Review of Centrifugal Testing of Gasoline Contamination and Remediation

    Directory of Open Access Journals (Sweden)

    Jay N. Meegoda

    2011-08-01

    Full Text Available Leaking underground storage tanks (USTs containing gasoline represent a significant public health hazard. Virtually undetectable to the UST owner, gasoline leaks can contaminate groundwater supplies. In order to develop remediation plans one must know the extent of gasoline contamination. Centrifugal simulations showed that in silty and sandy soils gasoline moved due to the physical process of advection and was retained as a pool of free products above the water table. However, in clayey soils there was a limited leak with lateral spreading and without pooling of free products above the water table. Amount leaked depends on both the type of soil underneath the USTs and the amount of corrosion. The soil vapor extraction (SVE technology seems to be an effective method to remove contaminants from above the water table in contaminated sites. In-situ air sparging (IAS is a groundwater remediation technology for contamination below the water table, which involves the injection of air under pressure into a well installed into the saturated zone. However, current state of the art is not adequate to develop a design guide for site implementation. New information is being currently generated by both centrifugal tests as well as theoretical models to develop a design guide for IAS. The petroleum contaminated soils excavated from leaking UST sites can be used for construction of highway pavements, specifically as sub-base material or blended and used as hot or cold mix asphalt concrete. Cost analysis shows that 5% petroleum contaminated soils is included in hot or cold mix asphalt concrete can save US$5.00 production cost per ton of asphalt produced.

  10. ESA Parabolic Flight, Drop Tower and Centrifuge Opportunities for University Students

    Science.gov (United States)

    Callens, Natacha; Ventura-Traveset, Javier; Zornoza Garcia-Andrade, Eduardo; Gomez-Calero, Carlos; van Loon, Jack J. W. A.; Pletser, Vladimir; Kufner, Ewald; Krause, Jutta; Lindner, Robert; Gai, Frederic; Eigenbrod, Christian

    impact on a system over the whole acceleration spectrum, but can address as well specifically problems which require these high g-levels. A wide range of hypergravity exper-iments can be performed in the LDC facility, including biological, biochemical, microbiological, opto-physical, physical, material and fluid sciences, geology or plasma physics. ESA Education Office financially supports the cost of the campaigns, part of the hardware development, as well as necessary travel and accommodation of the student selected teams. An ELGRA (European Low Gravity Research Association) mentor, i.e. a scientist specialized in gravity-related research, support each student team throughout these education programmes. [1] Pletser V., Gharib T., Gai F., Mora C., Rosier P. "The 50 parabolic flight campaigns of the European Space Agency to conduct short duration microgravity research experimentation", Paper IAC-09-A2.5.1, 60th International Astronautical federation Congress, Daejeon, Korea, October 2009. [2] von Kampen P., Kaczmarczik U., Rath H.J. The new Drop Tower catapult system", Acta Astronautica, 59, 1-5, 278-283, 2006. [3] van Loon J. W. A. , Krause J., Cunha H., Goncalves J., Almeida H., Schiller P. "The Large Diameter Centrifuge, LDC, for life and physical sciences and technology", Proc. of the 'Life in Space for Life on Earth Symposium', Angers, France, 22-27 June 2008. (ESA SP-663, December 2008)

  11. 40 CFR 63.5810 - What are my options for meeting the standards for open molding and centrifugal casting operations...

    Science.gov (United States)

    2010-07-01

    ... standards for open molding and centrifugal casting operations at new and existing sources? 63.5810 Section... § 63.5810 What are my options for meeting the standards for open molding and centrifugal casting... (d) of this section to meet the standards for open molding or centrifugal casting operations in...

  12. The variable rotation period of the inner region of Saturn's plasma disk.

    Science.gov (United States)

    Gurnett, D A; Persoon, A M; Kurth, W S; Groene, J B; Averkamp, T F; Dougherty, M K; Southwood, D J

    2007-04-20

    We show that the plasma and magnetic fields in the inner region of Saturn's plasma disk rotate in synchronism with the time-variable modulation period of Saturn's kilometric radio emission. This relation suggests that the radio modulation has its origins in the inner region of the plasma disk, most likely from a centrifugally driven convective instability and an associated plasma outflow that slowly slips in phase relative to Saturn's internal rotation. The slippage rate is determined by the electrodynamic coupling of the plasma disk to Saturn and by the drag force exerted by its interaction with the Enceladus neutral gas torus.

  13. Isolation of biologically-active exosomes from human plasma.

    Science.gov (United States)

    Muller, Laurent; Hong, Chang-Sook; Stolz, Donna B; Watkins, Simon C; Whiteside, Theresa L

    2014-09-01

    Effects of exosomes present in human plasma on immune cells have not been examined in detail. Immunological studies with plasma-derived exosomes require their isolation by procedures involving ultracentrifugation. These procedures were largely developed using supernatants of cultured cells. To test biologic activities of plasma-derived exosomes, methods are necessary that ensure adequate recovery of exosome fractions free of contaminating larger vesicles, cell fragments and protein/nucleic acid aggregates. Here, an optimized method for exosome isolation from human plasma/serum specimens of normal controls (NC) or cancer patients and its advantages and pitfalls are described. To remove undesirable plasma-contaminating components, ultrafiltration of differentially-centrifuged plasma/serum followed by size-exclusion chromatography prior to ultracentrifugation facilitated the removal of contaminants. Plasma or serum was equally acceptable as a source of exosomes based on the recovered protein levels (in μg protein/mL plasma) and TEM image quality. Centrifugation on sucrose density gradients led to large exosome losses. Fresh plasma was the best source of morphologically-intact exosomes, while the use of frozen/thawed plasma decreased exosome purity but not their biologic activity. Treatments of frozen plasma with DNAse, RNAse or hyaluronidase did not improve exosome purity and are not recommended. Cancer patients' plasma consistently yielded more isolated exosomes than did NCs' plasma. Cancer patients' exosomes also mediated higher immune suppression as evidenced by decreased CD69 expression on responder CD4+ T effector cells. Thus, the described procedure yields biologically-active, morphologically-intact exosomes that have reasonably good purity without large protein losses and can be used for immunological, biomarker and other studies.

  14. Dusty plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Fortov, Vladimir E; Khrapak, Aleksei G; Molotkov, Vladimir I; Petrov, Oleg F [Institute for High Energy Densities, Associated Institute for High Temperatures, Russian Academy of Sciences, Moscow (Russian Federation); Khrapak, Sergei A [Max-Planck-Institut fur Extraterrestrische Physik, Garching (Germany)

    2004-05-31

    The properties of dusty plasmas - low-temperature plasmas containing charged macroparticles - are considered. The most important elementary processes in dusty plasmas and the forces acting on dust particles are investigated. The results of experimental and theoretical investigations of different states of strongly nonideal dusty plasmas - crystal-like, liquid-like, gas-like - are summarized. Waves and oscillations in dusty plasmas, as well as their damping and instability mechanisms, are studied. Some results on dusty plasma investigated under microgravity conditions are presented. New directions of experimental research and potential applications of dusty plasmas are discussed. (reviews of topical problems)

  15. Effect of pumping chamber on performance of non-overload centrifugal pump

    Institute of Scientific and Technical Information of China (English)

    谷云庆; 吴登昊; 牟介刚; 蒋兰芳; 代东顺; 施瀚昱; 郑水华

    2015-01-01

    In order to specify the characteristics of un-overloaded centrifugal pumps, the IH100-65-200 pump was chosen as the model pump. Different calculation models for centrifugal pumps were established under different pumping chamber sectional parameters. In the numerical simulation of the centrifugal pumps flow field, the shaft power, head, efficiency, and the changes of the internal flow field under different sectional areas and sectional shapes were studied with the RNGk−εturbulence model, and the influence of the pumping chamber section characteristics of the non-overloaded centrifugal pumps were analyzed. The results show that sectional areas have a significant impact on the non-overload characteristics of centrifugal pumps. The shaft power and head of centrifugal pump are increasing with a lager sectional area, by which the gradient of head curves decreases. The efficiency is improved under a large flow rate condition, but the head and the efficiency are reduced at a small flow rate. It is also observed that the sectional shapes have less influence on the shaft power, the hydraulic performance and flow field characteristics of a centrifugal pump.

  16. Fabrication of silk fibroin film using centrifugal casting technique for corneal tissue engineering.

    Science.gov (United States)

    Lee, Min Chae; Kim, Dong-Kyu; Lee, Ok Joo; Kim, Jung-Ho; Ju, Hyung Woo; Lee, Jung Min; Moon, Bo Mi; Park, Hyun Jung; Kim, Dong Wook; Kim, Su Hyeon; Park, Chan Hum

    2016-04-01

    Films prepared from silk fibroin have shown potential as biomaterials in tissue engineering applications for the eye. Here, we present a novel process for fabrication of silk fibroin films for corneal application. In this work, fabrication of silk fibroin films was simply achieved by centrifugal force. In contrast to the conventional dry casting method, we carried out the new process in a centrifuge with a rotating speed of 4000 rpm, where centrifugal force was imposed on an aluminum tube containing silk fibroin solution. In the present study, we also compared the surface roughness, mechanical properties, transparency, and cell proliferation between centrifugal and dry casting method. In terms of surface morphology, films fabricated by the centrifugal casting have less surface roughness than those by the dry casting. For elasticity and transparency, silk fibroin films obtained from the centrifugal casting had favorable results compared with those prepared by dry casting. Furthermore, primary human corneal keratocytes grew better in films prepared by the centrifugal casting. Therefore, our results suggest that this new fabrication process for silk fibroin films offers important potential benefits for corneal tissue regeneration.

  17. In vitro pulsatility analysis of axial-flow and centrifugal-flow left ventricular assist devices.

    Science.gov (United States)

    Stanfield, J Ryan; Selzman, Craig H

    2013-03-01

    Recently, continuous-flow ventricular assist devices (CF-VADs) have supplanted older, pulsatile-flow pumps, for treating patients with advanced heart failure. Despite the excellent results of the newer generation devices, the effects of long-term loss of pulsatility remain unknown. The aim of this study is to compare the ability of both axial and centrifugal continuous-flow pumps to intrinsically modify pulsatility when placed under physiologically diverse conditions. Four VADs, two axial- and two centrifugal-flow, were evaluated on a mock circulatory flow system. Each VAD was operated at a constant impeller speed over three hypothetical cardiac conditions: normo-tensive, hypertensive, and hypotensive. Pulsatility index (PI) was compared for each device under each condition. Centrifugal-flow devices had a higher PI than that of axial-flow pumps. Under normo-tension, flow PI was 0.98 ± 0.03 and 1.50 ± 0.02 for the axial and centrifugal groups, respectively (p centrifugal pumps, respectively (p = 0.01). Under hypotension, PI was 0.73 ± 0.02 and 0.78 ± 0.02 for the axial and centrifugal groups, respectively (p = 0.13). All tested CF-VADs were capable of maintaining some pulsatile-flow when connected in parallel with our mock ventricle. We conclude that centrifugal-flow devices outperform the axial pumps from the basis of PI under tested conditions.

  18. Centrifugal force induces human ligamentum flavum fibroblasts inflammation through activation of JNK and p38 pathways.

    Science.gov (United States)

    Chao, Yuan-Hung; Tsuang, Yang-Hwei; Sun, Jui-Sheng; Sun, Man-Ger; Chen, Ming-Hong

    2012-01-01

    Inflammation has been proposed to be an important causative factor in ligamentum flavum hypertrophy. However, the mechanisms of mechanical load on inflammation of ligamentum flavum remain unclear. In this study, we used an in vitro model of human ligamentum flavum fibroblasts subjected to centrifugal force to elucidate the effects of mechanical load on cultured human ligamentum flavum fibroblasts; we further studied its molecular and biochemical mechanisms. Human ligamentum flavum fibroblasts were obtained from six patients undergoing lumbar spine surgery. Monolayer cultures of human ligamentum flavum fibroblasts were subjected to different magnitudes of centrifugal forces. Cell viability, cell death, biochemical response, and molecular response to centrifugal forces were analyzed. It was found that centrifugal stress significantly suppressed cell viability without inducing cell death. Centrifugal force at 67.1 g/cm(2) for 60 min significantly increases the production of prostaglandin E2 and nitric oxide as well as gene expression of proinflammatory cytokines, including interleukin (IL)-1α, IL-1β and IL-6, showed that centrifugal force-dependent induction of cyclooxygense-2 and inducible NO synthase required JNK and p38 mitogen-activated protein kinase, but not ERK 1/2 activities. This study suggested that centrifugal force does induce inflammatory responses in human ligamentum flavum fibroblasts. The activation of both JNK and p38 mitogen-activated protein kinase mechanotransduction cascades is a crucial intracellular mechanism that mediates cyclooxygense-2/prostaglandin E2 and inducible NO synthase/nitric oxide production.

  19. Isolation of exosomes by differential centrifugation: Theoretical analysis of a commonly used protocol

    Science.gov (United States)

    Livshts, Mikhail A.; Khomyakova, Elena; Evtushenko, Evgeniy G.; Lazarev, Vassili N.; Kulemin, Nikolay A.; Semina, Svetlana E.; Generozov, Edward V.; Govorun, Vadim M.

    2015-11-01

    Exosomes, small (40-100 nm) extracellular membranous vesicles, attract enormous research interest because they are carriers of disease markers and a prospective delivery system for therapeutic agents. Differential centrifugation, the prevalent method of exosome isolation, frequently produces dissimilar and improper results because of the faulty practice of using a common centrifugation protocol with different rotors. Moreover, as recommended by suppliers, adjusting the centrifugation duration according to rotor K-factors does not work for “fixed-angle” rotors. For both types of rotors - “swinging bucket” and “fixed-angle” - we express the theoretically expected proportion of pelleted vesicles of a given size and the “cut-off” size of completely sedimented vesicles as dependent on the centrifugation force and duration and the sedimentation path-lengths. The proper centrifugation conditions can be selected using relatively simple theoretical estimates of the “cut-off” sizes of vesicles. Experimental verification on exosomes isolated from HT29 cell culture supernatant confirmed the main theoretical statements. Measured by the nanoparticle tracking analysis (NTA) technique, the concentration and size distribution of the vesicles after centrifugation agree with those theoretically expected. To simplify this “cut-off”-size-based adjustment of centrifugation protocol for any rotor, we developed a web-calculator.

  20. Effect of gelatin on the water dispersion and centrifugal purification of single-walled carbon nanotubes

    Science.gov (United States)

    Hanium Maria, Kazi; Mieno, Tetsu

    2016-01-01

    We report a convenient and effective procedure for the water dispersion and purification of single-walled carbon nanotubes (SWNTs). The purification procedure involves a combination of dispersion and centrifugation, in which gelatin; an environmentally friendly material is used as a dispersing agent. It has been found that an aqueous solution of gelatin effectively disperses SWNTs for more than a month. Another advantage of using gelatin as a dispersing agent is that it can be easily removed by washing with water and filtration. The centrifugation procedure employs a centrifugal force of about 2500 times the gravitational force to separate the particles. Although carbonaceous and metallic impurities usually have higher density than SWNTs in arc-produced carbon soot, the centrifugation can easily remove impurities leaving undamaged SWNTs in solution when appropriate centrifugal force and a centrifugation time are used. Centrifugation is carried out for three times to sufficiently remove impurities. Finally, the SWNTs are separated from the gelatin by heating in water and filtering.

  1. Ultrasound-Assisted Extraction, Centrifugation and Ultrafiltration: Multistage Process for Polyphenol Recovery from Purple Sweet Potatoes

    Directory of Open Access Journals (Sweden)

    Zhenzhou Zhu

    2016-11-01

    Full Text Available This work provides an evaluation of an ultrasound-assisted, combined extraction, centrifugation and ultrafiltration process for the optimal recovery of polyphenols. A purple sweet potato (PSP extract has been obtained using ultrasonic circulating extraction equipment at a power of 840 W, a frequency of 59 kHz and using water as solvent. Extract ultrafiltration, using polyethersulfone (PES, was carried out for the recovery of polyphenol, protein and anthocyanin. Pre-treatment, via the centrifugation of purple sweet potato extract at 2500 rpm over 6 min, led to better polyphenol recovery, with satisfactory protein removal (reused for future purposes, than PSP extract filtration without centrifugation. Results showed that anthocyanin was efficiently recovered (99% from permeate. The exponential model fit well with the experimental ultrafiltration data and led to the calculation of the membrane’s fouling coefficient. The optimization of centrifugation conditions showed that, at a centrifugation speed of 4000 rpm (1195× g and duration of 7.74 min, the optimized polyphenol recovery and fouling coefficient were 34.5% and 29.5 m−1, respectively. The removal of proteins in the centrifugation process means that most of the anthocyanin content (90% remained after filtration. No significant differences in the intensities of the HPLC-DAD-ESI-MS2 peaks were found in the samples taken before and after centrifugation for the main anthocyanins; peonidin-3-feruloylsophoroside-5-glucoside, peonidin-3-caffeoyl-p-hydroxybenzoylsophoroside-5-glucoside, and peonidin-3-caffeoyl-feruloyl sophoroside-5-glucoside. This proves that centrifugation is an efficient method for protein removal without anthocyanin loss. This study considers this process an ultrasound-assisted extraction-centrifugation-ultrafiltration for purple sweet potato valorization in “green” technology.

  2. Expression of myosin heavy-chain mRNA in cultured myoblasts induced by centrifugal force.

    Science.gov (United States)

    Kurokawa, Katsuhide; Sakiyama, Koji; Abe, Shinichi; Hiroki, Emi; Naito, Kaoru; Nakajima, Kazunori; Takeda, Tomotaka; Inoue, Takashi; Ide, Yoshinobu; Ishigami, Keiichi

    2008-11-01

    Ballistic muscle training leads to hypertrophy of fast type fibers and training for endurance induces that of slow type fibers. Numerous studies have been conducted on electrical, extending and magnetic stimulation of cells, but the effect of centrifugal force on cells remains to be investigated. In this study, we investigated the effect of stimulating cultured myoblasts with centrifugal force at different speeds on cell proliferation and myosin heavy-chain (MyHC) mRNA expression in muscle fiber. Stimulation of myoblasts was carried out at 2 different speeds for 20 min using the Himac CT6D, a desk centrifuge, and cells were observed at 1, 3 and 5 days later. Number of cells 1 and 5 days after centrifugal stimulation was significantly larger in the 62.5 x g and 4,170 x g stimulation groups than in the control group. Expression of MyHC-2b mRNA 1 day after centrifugal stimulation was significantly higher in the 2 stimulation groups than in the control group. Almost no expression of MyHC-2a was observed in any group at 1 and 3 days after centrifugal stimulation. However, 5 days after stimulation, MyHC-2a was strongly expressed in the 2 stimulation groups in comparison to the control group. Three days after centrifugal stimulation, expression of MyHC-1 was significantly higher in the 2 stimulation groups than in the control group. The results of this study clarified the effect of different centrifugal stimulation speeds on muscle fiber characteristics, and suggest that centrifugal stimulation of myoblasts enhances cell proliferation.

  3. Cross-field plasma injection into mirror geometry

    Science.gov (United States)

    Uzun-Kaymak, I. U.; Messer, S.; Bomgardner, R.; Case, A.; Clary, R.; Ellis, R.; Elton, R.; Teodorescu, C.; Witherspoon, F. D.; Young, W.

    2009-09-01

    The Maryland Centrifugal Experiment (MCX) and HyperV Technologies Corp. are collaborating on a series of experiments to test the use of a plasma gun to inject mass and momentum into a magnetic-confinement device. HyperV has designed, built and installed a prototype coaxial gun to drive rotation in MCX. The gun has been designed to avoid the blow-by instability via a combination of electrode shaping and a tailored plasma armature. Preliminary measurements at HyperV indicate the gun generates plasma jets with a mass of 160 µg, velocities up to 90 km s-1 and plasma density in the high 1014 cm-3. This paper emphasizes characteristics of the plasma gun and penetration of the plasma jet through the MCX magnetic field. Plans for future injection experiments are briefly discussed.

  4. Study on High-Speed Centrifugal-Regenerative Pump with an Inducer

    Institute of Scientific and Technical Information of China (English)

    朱祖超; 陈鹰; 金庆明; 黄敦回

    2002-01-01

    The study on high-speed centrifugal-regenerative pumps with an inducer (HCRP) is carried out. Thecombined structure of inducer, centrifugal impeller, and regenerative impeller is presented, and a theoretical parallelcombinatorial hydraulic design method is investigated. The comparative experimental results show that efficiency insmaller capacity region, head coefficient and efficiency in larger capacity region of HCRPs is few lower, much higherand lower than those of high-speed centrifugal pumps, respectively, anci that the suction performance of HCRPs isdetermined only by inducer. HCRPs can be more suitably applied to deliver small-capacity high-head liquids inchemical and petrochemical industries.

  5. EXPERIMENTAL STUDY ON HIGH-SPEED CENTRIFUGAL PUMPS WITH DIFFERENT IMPELLERS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The experimental study is carded out on high-speed centrifugal pumps with three different impellers. The ex-perimental results and analysis show that high-speed centrifugal pumps with a closed complex impeller can achieve thehighest efficiency and the lowest head coefficient followed by those with half-open impeller and open-impeller, and canobtain much easily stable head-capacity characrastic curve, while those with a half-open complex impeller can't. Thecharacteristic curve with a open impeller is almost constant horizontal line before dropping sharply. The results also showthat the axial clearance between pump casing and impeller can influence greatly on the performance of centrifugal pumps.

  6. Comparative Centrifugal Distortion Analysis in Rotational Spectra of Propanol and Isopropanol Molecules

    Science.gov (United States)

    Qajar, Ch. O.; Kazimova, S. B.

    2015-07-01

    We have compared the effect of centrifugal distortion on the rotational spectra of isopropanol and propanol molecules in the microwave frequency range. We identified 61 rotational transitions of the propanol molecule with rotational quantum numbers up to J = 36 inclusive. We show that in order to satisfactorily take into account centrifugal distortion in the isopropanol molecule, it is sufficient to use only the quartic and sextic terms, while in calculating the rotational transitions of the propanol molecule we need to include all the way up to dectic centrifugal distortion constants.

  7. [Usefulness of the Centrifuge Accommodation Module for analyzing gravity responses in plant seedlings].

    Science.gov (United States)

    Hoson, T

    2001-10-01

    Onboard centrifuges are indispensable tools for clarifying the effects of microgravity on various physiological processes in plant seedlings. Centrifuges are basically attached to the incubators designed for the International Space Station (ISS). However, because of the limitation in size, that loaded to the Cell Biology Experiment Facility (CBEF) is usable only to some small seedlings such as Arabidopsis. The Centrifuge Accommodation Module (CAM) has great advantages in the size and the amounts of plant materials feasible to load, the quality of acceleration produced, and the easiness of operation on it. The CAM is an apparatus that characterizes the ISS most and its construction on schedule is highly expected.

  8. Numerical and experimental evaluation of performance of centrifugal seals

    Indian Academy of Sciences (India)

    T V SANAND; P PRADEEP KUMAR; P UNNIKRISHNAN NAIR; PAUL P GEORGE

    2017-04-01

    Centrifugal seals’ or ‘Slinger seals’ offer an attractive choice as non-contact-type sealing in fluid machinery. These seals utilize the radial pressure gradient caused by centrifugal forces in a rotating fluid ring, to create a sealing of the working fluid. Basic construction of a typical seal consists of a rotating disc inside astationary casing; one side of the disc (sealing side) is provided with a set of slots (Type-1) or vanes (Type-2) to enhance the tangential velocity of the fluid. The other side of the disk (back side) in both the configurations is exposed to high pressure liquid being sealed. Both numerical and experimental investigations of the performance of Type-1 seal (with slots) have been carried out so as to optimize the seal configuration to achieve maximum sealing capacity, with minimum power consumption. A comparison of the performance of Type-1 seal has been made with that of conventional one (Type-2) in view of economy of construction and better sealing with minimal expense of power consumption. A test rig that allows for varying the major geometrical and operating parameters was designed and tests were conducted with water as the medium. Influence of major geometric parameters like dimensions and number of slots, axial/radial clearances and major operating parameters like rotational speed, inlet pressure and sealing fluid bypass flow rate has been investigated. Apart from variouspressure, temperature, flow and torque measurements, the interface between the sealing and working fluid for the experiments was captured and recorded using a high speed camera at 26,000 frames per second. Geometrical configuration for the slots that maximizes the sealing capacity is arrived through 3D numerical simulations using commercial CFD solver ANSYS Fluent®. A good agreement is obtained with respect to experimental results. In view of economy of construction and better sealing with minimal expense of operating power, a modified version of Type-1 seal

  9. Oil-free centrifugal hydrogen compression technology demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Heshmat, Hooshang [Mohawk Innovative Technology Inc., Albany, NY (United States)

    2014-05-31

    One of the key elements in realizing a mature market for hydrogen vehicles is the deployment of a safe and efficient hydrogen production and delivery infrastructure on a scale that can compete economically with current fuels. The challenge, however, is that hydrogen, being the lightest and smallest of gases with a lower viscosity and density than natural gas, readily migrates through small spaces and is difficult to compresses efficiently. While efficient and cost effective compression technology is crucial to effective pipeline delivery of hydrogen, the compression methods used currently rely on oil lubricated positive displacement (PD) machines. PD compression technology is very costly, has poor reliability and durability, especially for components subjected to wear (e.g., valves, rider bands and piston rings) and contaminates hydrogen with lubricating fluid. Even so called “oil-free” machines use oil lubricants that migrate into and contaminate the gas path. Due to the poor reliability of PD compressors, current hydrogen producers often install duplicate units in order to maintain on-line times of 98-99%. Such machine redundancy adds substantially to system capital costs. As such, DOE deemed that low capital cost, reliable, efficient and oil-free advanced compressor technologies are needed. MiTi’s solution is a completely oil-free, multi-stage, high-speed, centrifugal compressor designed for flow capacity of 500,000 kg/day with a discharge pressure of 1200 psig. The design employs oil-free compliant foil bearings and seals to allow for very high operating speeds, totally contamination free operation, long life and reliability. This design meets the DOE’s performance targets and achieves an extremely aggressive, specific power metric of 0.48 kW-hr/kg and provides significant improvements in reliability/durability, energy efficiency, sealing and freedom from contamination. The multi-stage compressor system concept has been validated through full scale

  10. Plasma waves

    CERN Document Server

    Swanson, DG

    1989-01-01

    Plasma Waves discusses the basic development and equations for the many aspects of plasma waves. The book is organized into two major parts, examining both linear and nonlinear plasma waves in the eight chapters it encompasses. After briefly discussing the properties and applications of plasma wave, the book goes on examining the wave types in a cold, magnetized plasma and the general forms of the dispersion relation that characterize the waves and label the various types of solutions. Chapters 3 and 4 analyze the acoustic phenomena through the fluid model of plasma and the kinetic effects. Th

  11. Plasma astrophysics

    CERN Document Server

    Kaplan, S A; ter Haar, D

    2013-01-01

    Plasma Astrophysics is a translation from the Russian language; the topics discussed are based on lectures given by V.N. Tsytovich at several universities. The book describes the physics of the various phenomena and their mathematical formulation connected with plasma astrophysics. This book also explains the theory of the interaction of fast particles plasma, their radiation activities, as well as the plasma behavior when exposed to a very strong magnetic field. The text describes the nature of collective plasma processes and of plasma turbulence. One author explains the method of elementary

  12. Comparison between the effects of platelet-rich plasma and bone marrow concentrate on defect consolidation in the rabbit tibia

    Science.gov (United States)

    Batista, Marco Antonio; Leivas, Tomaz Puga; Rodrigues, Consuelo Junqueira; Arenas, Géssica Cantadori Funes; Belitardo, Donizeti Rodrigues; Guarniero, Roberto

    2011-01-01

    OBJECTIVE: To perform a comparative analysis of the effects of platelet-rich plasma and centrifuged bone marrow aspirate on the induction of bone healing in rabbits. METHOD: Twenty adult, male New Zealand rabbits were randomly separated into two equal groups, and surgery was performed to create a bone defect (a cortical orifice 3.3 mm in diameter) in the proximal metaphysis of each rabbit's right tibia. In the first group, platelet-rich plasma was implanted in combination with β-tricalcium phosphate (platelet-rich plasma group), and in the second group, centrifuged bone marrow in combination with β-tricalcium phosphate (centrifuged bone marrow group) was implanted. After a period of four weeks, the animals were euthanized, and the tibias were evaluated using digital radiography, computed tomography, and histomorphometry. RESULTS: Seven samples from each group were evaluated. The radiographic evaluation confirmed the absence of fractures in the postoperative limb and identified whether bone consolidation had occurred. The tomographic evaluation revealed a greater amount of consolidation and the formation of a greater cortical bone thickness in the platelet-rich plasma group. The histomorphometry revealed a greater bone density in the platelet-rich plasma group compared with the centrifuged bone marrow group. CONCLUSION: After four weeks, the platelet-rich plasma promoted a greater amount of bone consolidation than the bone marrow aspirate concentrate. PMID:22012052

  13. Comparison between the effects of platelet-rich plasma and bone marrow concentrate on defect consolidation in the rabbit tibia

    Directory of Open Access Journals (Sweden)

    Marco Antonio Batista

    2011-01-01

    Full Text Available OBJECTIVE: To perform a comparative analysis of the effects of platelet-rich plasma and centrifuged bone marrow aspirate on the induction of bone healing in rabbits. METHOD: Twenty adult, male New Zealand rabbits were randomly separated into two equal groups, and surgery was performed to create a bone defect (a cortical orifice 3.3 mm in diameter in the proximal metaphysis of each rabbit's right tibia. In the first group, platelet-rich plasma was implanted in combination with β-tricalcium phosphate (platelet-rich plasma group, and in the second group, centrifuged bone marrow in combination with β-tricalcium phosphate (centrifuged bone marrow group was implanted. After a period of four weeks, the animals were euthanized, and the tibias were evaluated using digital radiography, computed tomography, and histomorphometry. RESULTS: Seven samples from each group were evaluated. The radiographic evaluation confirmed the absence of fractures in the postoperative limb and identified whether bone consolidation had occurred. The tomographic evaluation revealed a greater amount of consolidation and the formation of a greater cortical bone thickness in the platelet-rich plasma group. The histomorphometry revealed a greater bone density in the platelet-rich plasma group compared with the centrifuged bone marrow group. CONCLUSION: After four weeks, the platelet-rich plasma promoted a greater amount of bone consolidation than the bone marrow aspirate concentrate.

  14. Centrifugal pump or pneumatic ventricle for short-term mechanical circulatory support?

    Science.gov (United States)

    Deleuze, P H; Liu, Y; Tixier, D; Okude, J; Leandri, J; Gouault, M; Galacteros, F; Cachera, J P; Loisance, D

    1989-05-01

    Two comparable groups of four Holstein calves were implanted with different left ventricle assist devices: the Centrimed centrifugal pump (CP) (Sarns Inc.) or the UTAH 85 VAD pneumatic ventricle (University of Utah). Operative procedure, inflow and outflow cannulae, monitoring, heparinization, were identical in both groups. No transfusion was ever required. The study was terminated after three days and autopsy was performed on the calves. Left ventricular unloading provided by both devices was complete (LVEDP less than 1 mmHg) and identical. LV bypassed flow rate was higher in CP (0.045 L/min/kg) than in UTAH 85 VAD (0.035 L/min/kg) but with no statistical difference. Blood trauma was comparable in the two groups. Daily blood samples did not show any significant changes from baseline values in creatinine, hematocrit, fibrinogen. Platelet loss from initial level was 30%; serum lactate dehydrogenase rose 150% with no significant difference in the two groups; plasma free hemoglobin never reached significant values. At autopsy, thrombotic deposits on cannuale and renal infarction rate were similar. CP housing had to be changed every day, whereas no technical failure was ever observed with the UTAH 85 VAD. Clinical response and blood damage of the two pumps used as LVAD were the same. Considering the CP has to be replaced every 24 h, the cost of three CP's would be comparable to one Utah UVAD-85 if polyurethane tricusp semi-lunar valves are used in the latter. Until the UTAH-85 VAD becomes commercially available, simple valveless low-cost CP are very attractive for short-term mechanical support.

  15. Axial and Centrifugal Compressor Mean Line Flow Analysis Method

    Science.gov (United States)

    Veres, Joseph P.

    2009-01-01

    This paper describes a method to estimate key aerodynamic parameters of single and multistage axial and centrifugal compressors. This mean-line compressor code COMDES provides the capability of sizing single and multistage compressors quickly during the conceptual design process. Based on the compressible fluid flow equations and the Euler equation, the code can estimate rotor inlet and exit blade angles when run in the design mode. The design point rotor efficiency and stator losses are inputs to the code, and are modeled at off design. When run in the off-design analysis mode, it can be used to generate performance maps based on simple models for losses due to rotor incidence and inlet guide vane reset angle. The code can provide an improved understanding of basic aerodynamic parameters such as diffusion factor, loading levels and incidence, when matching multistage compressor blade rows at design and at part-speed operation. Rotor loading levels and relative velocity ratio are correlated to the onset of compressor surge. NASA Stage 37 and the three-stage NASA 74-A axial compressors were analyzed and the results compared to test data. The code has been used to generate the performance map for the NASA 76-B three-stage axial compressor featuring variable geometry. The compressor stages were aerodynamically matched at off-design speeds by adjusting the variable inlet guide vane and variable stator geometry angles to control the rotor diffusion factor and incidence angles.

  16. Fast Pyrolysis of Lignin Using a Pyrolysis Centrifuge Reactor

    DEFF Research Database (Denmark)

    Trinh, Ngoc Trung; Jensen, Peter Arendt; Sárossy, Zsuzsa

    2013-01-01

    Fast pyrolysis of lignin from an ethanol plant was investigated on a lab scale pyrolysis centrifuge reactor (PCR) with respect to pyrolysis temperature, reactor gas residence time, and feed rate. A maximal organic oil yield of 34 wt % dry basis (db) (bio-oil yield of 43 wt % db) is obtained...... at temperatures of 500−550 °C, reactor gas residence time of 0.8 s, and feed rate of 5.6 g/min. Gas chromatography mass spectrometry and size-exclusion chromatography were used to characterize the Chemical properties of the lignin oils. Acetic acid, levoglucosan, guaiacol, syringols, and p-vinylguaiacol are found...... to be major chemical components in the lignin oil. The maximal yields of 0.62, 0.67, and 0.38 wt % db were obtained for syringol, p-vinylguaiacol, and guaiacol, respectively. The reactor temperature effect was investigated in a range of 450−600 °C and has a considerable effect on the observed chemical...

  17. New approach for porous materials obtaining using centrifugal casting

    Science.gov (United States)

    Bălţătescu, O.; Axinte, M.; Barbu, G.; Manole, V.

    2015-11-01

    It has been presented different methods for obtaining porous materials, (mainly used for metallic foams) and highlighting a new technology developed in the Faculty of Materials science and engineering, of Iasi. Our technology for obtaining porous materials is called centrifugal casting for porous materials. This technology is included in the method number 8: co-pressing of a metal powder with a leachable powder being in the same time a newer approach in the porous materials field. This technology is currently in the developmental phase. Since now we made experiments on the metallic materials, aluminum alloys. The technology is briefly described in this paper. The obtained parts were used for making samples in order to characterize the properties of the materials. The cellular structure of metallic foams requires special precautions that must be taken in characterization and testing. In this paper we have characterized the samples structurally by its cell topology (open cells, closed cells), relative density, cell size and cell shape and anisotropy. Also it was used scanning electron microscopy (SEM) which is straightforward; the only necessary precaution is that relating to surface preparation.

  18. Casting behavior of titanium alloys in a centrifugal casting machine.

    Science.gov (United States)

    Watanabe, K; Miyakawa, O; Takada, Y; Okuno, O; Okabe, T

    2003-05-01

    Since dental casting requires replication of complex shapes with great accuracy, this study examined how well some commercial titanium alloys and experimental titanium-copper alloys filled a mold cavity. The metals examined were three types of commercial dental titanium [commercially pure titanium (hereinafter noted as CP-Ti), Ti-6Al-4V (T64) and Ti-6Al-7Nb (T67)], and experimental titanium-copper alloys [3%, 5% and 10% Cu (mass %)]. The volume percentage filling the cavity was evaluated in castings prepared in a very thin perforated sheet pattern and cast in a centrifugal casting machine. The flow behavior of the molten metal was also examined using a so-called "tracer element technique." The amounts of CP-Ti and all the Ti-Cu alloys filling the cavity were similar; less T64 and T67 filled the cavity. However, the Ti-Cu alloys failed to reach the end of the cavities due to a lower fluidity compared to the other metals. A mold prepared with specially designed perforated sheets was effective at differentiating the flow behavior of the metals tested. The present technique also revealed that the more viscous Ti-Cu alloys with a wide freezing range failed to sequentially flow to the end of the cavity.

  19. Performance of a newly developed implantable centrifugal blood pump.

    Science.gov (United States)

    Tsukiya, T; Taenaka, Y; Tatsumi, E; Takano, H

    2001-01-01

    The performance of the newly developed implantable centrifugal blood pump was investigated in vitro. The pump was developed with the end goal of building a versatile system that includes a left ventricular assist system with an internal secondary battery or an implantable biventricular assist system with two implantable blood pumps. The hydrodynamic characteristics and efficiency of the blood pump were evaluated, and the mechanical damage to the blood caused by the blood pump was assessed through a hemolysis test using fresh goat blood. The pump could generate 120 mm Hg at a flow rate of 5 L/min and a motor speed of 2,500 rpm. The electric input power to the pump was approximately 5 watts under these working conditions. The hemolysis caused by the pump was a bit higher than that by the former model, but stayed within an acceptable range. Performance of the pump in vitro was considered sufficient for a left ventricular assist device, although further design improvement is necessary in terms of hemolysis and system efficiency to improve biocompatibility of the pump.

  20. A study on centrifugal casting of high speed steel roll

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    High speed steel (HSS) rolls can replace traditional rolls such as alloyed cast iron rolls and powder metallurgical (PM) hard alloy rolls. The main reasons for the replacement are that the wear resistance of low-cost alloyed cast iron rolls is poor and the cost of high-quality PM hard alloy rolls is very high. By means of centrifugal casting, HSS rolls having excellent wear resistance have been manufactured. The hardness of the HSS roll is 65~ 67 HRC, the range of variation is smaller than 2 HRC and its impact toughness is 15 J/cm2. The wear rate of HSS rolls used in the pre-finishing stands of high-speed hot wire-rod rolling mill reaches 2.5 × 10-4 mm per ton steel. Furthermore, the manufacturing cost of HSS rolls is significantly lower than that of PM hard alloy rolls; it is only 30 percent of that of PM hard alloy rolls.

  1. Solanidine isolation from Solanum tuberosum by centrifugal partition chromatography.

    Science.gov (United States)

    Attoumbré, Jacques; Giordanengo, Philippe; Baltora-Rosset, Sylvie

    2013-07-01

    The aim of this investigation was the preparative isolation of solanidine (aglycone of the two main potato glycoalkaloids: α-chaconine and α-solanine) from fresh Solanum tuberosum (cv. Pompadour) material by implementing a new preparation scheme using centrifugal partition chromatography (CPC). A setup for obtaining solanidine by hydrolysis of the glycoalkaloids found in the skin and sprouts of S. tuberosum was first developed. Then its isolation was carried out by the development of CPC conditions: the solvent system used for separation was ethyl acetate/butanol/water in the ratio 42.5:7.5:50 v/v/v, 0.6 g of crude extract were separated with a 8 mL/min flow rate of mobile phase while rotating at 2500 rpm. A run yielded 98 mg of solanidine (86.7% recovery from the crude extract) in a one-step separation. The purity of the isolated solanidine was over 98%. Thus, CPC has proven to be the method of choice to get solanidine of very high purity from S. tuberosum biomass in large quantities.

  2. Composite Fibers from Recycled Plastics Using Melt Centrifugal Spinning.

    Science.gov (United States)

    Zander, Nicole E; Gillan, Margaret; Sweetser, Daniel

    2017-09-06

    New methods are being developed to enable the production of value-added materials from high-volume, low-cost feedstocks arising from domestic recycling streams. In this work, recycled bottle-grade polyethylene terephthalate, polystyrene, and polypropylene were spun into fibers from the melt using a centrifugal spinning technique. Mono-component fibers and 50/50 blends of each polymer and a 33/33/33 blend of all three polymers were evaluated. Fiber morphology, chemistry, thermal, and mechanical properties were probed. Fiber diameters ranged from ca. 1 to over 12 µm, with polypropylene fibers having the smallest fiber diameters. Mono-component fibers were generally defect-free, while composite fibers containing polypropylene were beady. Fibers made from polyethylene terephthalate had the highest tensile strength, and the addition of polyethylene terephthalate to the other polymers improved the mechanical properties of the blends. Nano- and micro-fibers from both pure and mixed waste streams are expected to have applications in myriad areas such as ultra/micro-filtration, composites, and insulation.

  3. Design concepts for the Centrifuge Facility Life Sciences Glovebox

    Science.gov (United States)

    Sun, Sidney C.; Horkachuck, Michael J.; Mckeown, Kellie A.

    1989-01-01

    The Life Sciences Glovebox will provide the bioisolated environment to support on-orbit operations involving non-human live specimens and samples for human life sceinces experiments. It will be part of the Centrifuge Facility, in which animal and plant specimens are housed in bioisolated Habitat modules and transported to the Glovebox as part of the experiment protocols supported by the crew. At the Glovebox, up to two crew members and two habitat modules must be accommodated to provide flexibility and support optimal operations. This paper will present several innovative design concepts that attempt to satisfy the basic Glovebox requirements. These concepts were evaluated for ergonomics and ease of operations using computer modeling and full-scale mockups. The more promising ideas were presented to scientists and astronauts for their evaluation. Their comments, and the results from other evaluations are presented. Based on the evaluations, the authors recommend designs and features that will help optimize crew performance and facilitate science accommodations, and specify problem areas that require further study.

  4. Optimal Design of a Centrifugal Compressor Impeller Using Evolutionary Algorithms

    Directory of Open Access Journals (Sweden)

    Soo-Yong Cho

    2012-01-01

    Full Text Available An optimization study was conducted on a centrifugal compressor. Eight design variables were chosen from the control points for the Bezier curves which widely influenced the geometric variation; four design variables were selected to optimize the flow passage between the hub and the shroud, and other four design variables were used to improve the performance of the impeller blade. As an optimization algorithm, an artificial neural network (ANN was adopted. Initially, the design of experiments was applied to set up the initial data space of the ANN, which was improved during the optimization process using a genetic algorithm. If a result of the ANN reached a higher level, that result was re-calculated by computational fluid dynamics (CFD and was applied to develop a new ANN. The prediction difference between the ANN and CFD was consequently less than 1% after the 6th generation. Using this optimization technique, the computational time for the optimization was greatly reduced and the accuracy of the optimization algorithm was increased. The efficiency was improved by 1.4% without losing the pressure ratio, and Pareto-optimal solutions of the efficiency versus the pressure ratio were obtained through the 21st generation.

  5. Centrifugal Distortion Causes Anderson Localization in Laser Kicked Molecules

    Science.gov (United States)

    Floss, Johannes; Averbukh, Ilya Sh.

    2014-05-01

    The periodically kicked 2D rotor is a textbook model in nonlinear dynamics. The classical kicked rotor can exhibit truly chaotic motion, whilst in the quantum regime this chaotic motion is suppressed by a mechanism similar to Anderson Localization. Up to now, these effects have been mainly observed in an atom optics analogue of a quantum rotor: cold atoms in a standing light wave. We demonstrate that common linear molecules (like N2, O2, CO2, ...), kicked by a train of short linearly polarized laser pulses, can exhibit a new mechanism for dynamical Anderson Localization due to their non-rigidity. When the pulses are separated by the rotational revival time trev = πℏ / B , the angular momentum J grows ballistically (Quantum Resonance). We show that, due to the centrifugal distortion of fast spinning molecules, above some critical value J =Jcr the Quantum Resonance is suppressed via the mechanism of Anderson Localization. This leads to a non-sinusoidal oscillation of the angular momentum distribution, which may be experimentally observed even at ambient conditions by using current techniques for laser molecular alignment.

  6. A cubesat centrifuge for long duration milligravity research.

    Science.gov (United States)

    Asphaug, Erik; Thangavelautham, Jekan; Klesh, Andrew; Chandra, Aman; Nallapu, Ravi; Raura, Laksh; Herreras-Martinez, Mercedes; Schwartz, Stephen

    2017-01-01

    We advocate a low-cost strategy for long-duration research into the 'milligravity' environment of asteroids, comets and small moons, where surface gravity is a vector field typically less than 1/1000 the gravity of Earth. Unlike the microgravity environment of space, there is a directionality that gives rise, over time, to strangely familiar geologic textures and landforms. In addition to advancing planetary science, and furthering technologies for hazardous asteroid mitigation and in situ resource utilization, simplified access to long-duration milligravity offers significant potential for advancing human spaceflight, biomedicine and manufacturing. We show that a commodity 3U (10 × 10 × 34 cm(3)) cubesat containing a laboratory of loose materials can be spun to 1 r.p.m. = 2π/60 s(-1) on its long axis, creating a centrifugal force equivalent to the surface gravity of a kilometer-sized asteroid. We describe the first flight demonstration, where small meteorite fragments will pile up to create a patch of real regolith under realistic asteroid conditions, paving the way for subsequent missions where landing and mobility technology can be flight-proven in the operational environment, in low-Earth orbit. The 3U design can be adapted for use onboard the International Space Station to allow for variable gravity experiments under ambient temperature and pressure for a broader range of experiments.

  7. Centrifugal barrel polishing of 1.3 GHz Nb cavities

    Energy Technology Data Exchange (ETDEWEB)

    Tamashevich, Yegor; Foster, Brian [DESY, Hamburg (Germany); Hamburg Univ. (Germany); Navitski, Aliaksandr; Steder, Lea; Elsen, Eckhard [DESY, Hamburg (Germany)

    2013-07-01

    Superconducting radio-frequency (SRF) cavities are the key components of particle accelerators such as the European X-ray Free Electron Laser (XFEL, under construction) and the planned future International Linear Collider (ILC). Steady progress in surface treatment techniques of SRF cavities in both the achievable quality factor Q and the accelerating electric field Eacc makes new accelerators and ambitious projects feasible. One of the alternative surface preparation techniques which is actually being explored is centrifugal barrel polishing (CBP) pioneered at KEK in Japan in mid-nineties by T. Hiuchi et al. CBP is a mechanical polishing of cavities and results in around 10 x smaller surface roughness and mirror-like surface as compared to chemistry alone. Q and E{sub acc} are expected to be at least as high as for chemically treated cavities. CBP eliminates the bulk chemistry and has the potential to completely replace the chemistry. The University of Hamburg is installing a CBP machine to study it as a cavity preparation and repair technique for 9-cell 1.3 GHz SRF cavities at the Deutsche Elektronen-Synchrotron (DESY). The setup and first commissioning tests will be presented and discussed.

  8. Autopsy findings in patients on postcardiotomy centrifugal ventricular assist.

    Science.gov (United States)

    Curtis, J J; Walls, J T; Boley, T M; Schmaltz, R A; Demmy, T L

    1992-01-01

    Reported experience with ventricular assist devices (VAD) routinely includes the rate of thromboembolic events, which is commonly calculated from clinically evident findings. Fifty-four patients have had postcardiotomy circulatory support with the Sarns centrifugal device at our institution. We have reviewed 43 patients who failed to survive VAD support to compare the thromboembolism rate diagnosed clinically to that determined at autopsy. In the 35 patients who had no autopsy, there was one clinically apparent thromboembolic event (2.3%). In eight similar patients who had autopsy, there was no clinically apparent thromboembolism. Five of these eight patients (63%) had acute thromboembolic infarcts determined at autopsy. Three had evidence of pulmonary thromboembolism, two cerebrovascular infarction, two liver infarcts, two splenic infarcts, two kidney infarcts, and one each gastric, pancreatic, prostate, adrenal, cervical, and ileal infarcts. All had left and/or right ventricular infarctions. It is concluded that patients dying following VAD have commonly suffered perioperative myocardial infarction. When evaluating complications associated with VAD, one should consider that the true incidence of thromboembolic events is underestimated by clinical findings.

  9. Evaluation of floating impeller phenomena in a Gyro centrifugal pump.

    Science.gov (United States)

    Nishimura, Ikuya; Ichikawa, S; Mikami, M; Ishitoya, H; Motomura, T; Kawamura, M; Linneweber, J; Glueck, J; Shinohara, T; Nosé, Y

    2013-01-01

    The Gyro centrifugal pump developed as a totally implantable artificial heart was designed with a free impeller, in which the rotational shaft (male bearing) of the impeller was completely separated from the female bearing. For this type of pump, it is very important to keep the proper magnet balance (impeller-magnet and actuator-magnet) in order to prevent thrombus formation and/or bearing wear. When the magnet balance is not proper, the impeller is jerked down into the bottom bearing. On the other hand, if magnet balance is proper, the impeller lifted off the bottom of the pump housing within a certain range of pumping conditions. In this study, this floating phenomenon was investigated in detail. The floating phenomenon was proved by observation of the impeller behavior using a transparent acrylic pump. The impeller floating phenomenon was mapped on a pump performance curve. The impeller floating phenomenon is affected by the magnet-magnet coupling distance and rotational speed of the impeller. In order to keep the proper magnet balance and to maintain the impeller floating phenomenon at the driving condition of right and left pump, the magnet-magnet coupling distance was altered by a spacer which was installed between the pump and actuator. It became clear that the same pump could handle different conditions (right and left ventricular assist), by just changing the thickness of the spacer. When magnet balance is proper, the floating impeller phenomenon occurs automatically in response to the impeller rev. It is called "the dynamic RPM suspension".

  10. Isolation of Methoxyfuranocoumarins From Ammi majus by Centrifugal Partition Chromatography.

    Science.gov (United States)

    Bartnik, Magdalena; Mazurek, Anna Katarzyna

    2016-01-01

    Pure methoxyfuranocoumarins were isolated from Ammi majus L. by use of low-pressure column chromatography (LPCC) followed by centrifugal partition chromatography (CPC). The concentrated petroleum ether extract from fruits of A. majus was fractionated on a silica gel column using a gradient of ethyl acetate in dichloromethane (0-80%, v/v). Coumarin-rich fractions were analyzed by thin-layer chromatography (TLC) and high-performance liquid chromatography with diode array detection (HPLC/DAD). Xanthotoxin (8-MOP) and isopimpinellin (isoP), structurally similar compounds, were isolated in one fraction (FR6). To avoid multistep and long-lasting TLC preparation, optimization of CPC conditions has been performed. In one run, an effective separation of 8-MOP and isoP was achieved. The two-phase solvent system composed of n-hexane-ethyl acetate-methanol-water (10 : 8 : 10 : 9; v/v) in an ascending mode (the aqueous phase was a stationary phase, and the organic phase was a mobile phase), with flow rate 3 mL/min and rotation speed 1,600 r.p.m., was used. The identification and high purities of isolated 8-MOP (98.7%) and isoP (100%) were confirmed by HPLC/DAD assay, when compared with standards. The developed CPC method could be applied to the effective isolation of 8-MOP and isoP from plant extracts. The high purity of obtained compounds makes possible further exploitation of these components in biological studies.

  11. A study on centrifugal charaging pump shaft failure investigation

    Energy Technology Data Exchange (ETDEWEB)

    Jo, S. D.; Kim, B. K. [KEPCO, Woolsan (Korea, Republic of)

    2001-05-01

    Pump shafts in the centrifugal charging safety injection pumps in PWRs have been subject to occasional failures over the past several years. Service experience showed that the pump shaft failures can result in significant emergency repair and maintenance costs to the plant. Metallurgical investigations of the pump shafts fabricated prior to 1977 confirmed that the cracking was initiated at stress concentrations sitcs, such as a locknut thread root or a split ring groove, and progressed by a high cycle fatigue mechanism. Westinghouse implemented a series of improvements and upgrades to increase the safety margins and to mitigate the effect of the off-design operating conditions. These included design enhancements as well as material condition (heat treatment) modifications. The pump shaft upgrading program significantly improved the design life of the shafts but did not fully mitigate the issue. Investigation of recent failures of the upgraded shafts suggested that these failures are initiated by a combination of off-design loading events such as loss of flow or gas binding and a reduction of pump shaft resistance to cracking due to the aqueous environmental conditions.

  12. Central centrifugal cicatricial alopecia amalgamated with alopecia areata: immunologic findings

    Directory of Open Access Journals (Sweden)

    Ana Maria Abreu Velez

    2014-07-01

    Full Text Available Introduction: Both scarring and non-scarring alopecias exist; however, rare cases demonstrate features of both classes. Case Report: We describe an interesting alopecia case with amalgamated clinical, histologic and immunopathologic features of scarring and non-scarring alopecia. Specifically, the case displays combined features of alopecia areata (AA and of central centrifugal cicatricial alopecia (CCCA. A 36 year old female presented with symmetric, round, patchy hair loss on her scalp. Methods: Biopsies for hematoxylin and eosin (H&E examination, as well as for special stains, direct immunofluorescence (DIF and immunohistochemistry (IHC were performed. Results: The H&E biopsy revealed focally diminished hair follicular units, and sebaceous gland damage. Perifollicular concentric fibrosis was confirmed by Verhoeff elastin special staining. Antibodies to micelles were noted. Positive IHC staining for CD4, CD8, CD45 and multiple proteases and protease inhibitors was noted around selected follicular unit remnants. Conclusion: We present a rare alopecia, combining histologic features of CCCA with additional, selected immunologic features of AA.

  13. Inkjet-printed conductive features for rapid integration of electronic circuits in centrifugal microfluidics

    CSIR Research Space (South Africa)

    Kruger, J

    2015-05-01

    Full Text Available This work investigates the properties of conductive circuits inkjet-printed onto the polycarbonate discs used in CD-based centrifugal microfluidics, contributing towards rapidly prototyped electronic systems in smart ubiquitous biosensors, which...

  14. [Pay attention to physical test and drafting product standards of the centrifuge apparatus].

    Science.gov (United States)

    Xu, Hui; Jia, Yufei; Li, Haixin; Song, Jinzi

    2010-03-01

    Compare and analyze the standards related to centrifuge apparatus and make corresponding suggestions in allusion to the problems existed in the test method and physical performance during product standard drafting process.

  15. Nitrogen mineralization from anaerobically digested centrifuge cake and aged air-dried biosolids.

    Science.gov (United States)

    Kumar, Kuldip; Hundal, Lakhwinder S; Cox, Albert E; Granato, Thomas

    2014-09-01

    This study was conducted to estimate nitrogen (N) mineralization of anaerobically digested centrifuge cake from the Stickney Water Reclamation Plant (SWRP) and Calumet Water Reclamation Plant (CWRP), lagoon-aged air-dried biosolids from the CWRP, and Milorganite at three rates of application (0, 12.5 and 25 Mg ha(-1)). The N mineralized varied among biosolids as follows: Milorganite (44%) > SWRP centrifuge cake (35%) > CWRP centrifuge cake (31%) > aged air-dried (13%). The N mineralized in the SWRP cake (32%) and CWRP aged air-dried biosolids (12%) determined from the 15N study were in agreement with the first study. The N mineralization value for centrifuge cake biosolids observed in our study is higher than the value given in the Part 503 rule and Illinois Part 391 guidelines. These results will be used to fine-tune biosolids application rate to match crop N demand without compromising yield while minimizing any adverse effect on the environment.

  16. Effect of Mould Wall Thickness on Rate of Solidification of Centrifugal Casting

    Directory of Open Access Journals (Sweden)

    Madhusudhan

    2010-11-01

    Full Text Available In Centrifugal Casting process the centrifugal force presses the metal against the inner wall of the metal mould, resulting in rapid solidification of the molten metal. However the solidification structures like structural uniformity and structural character of the solidified metal of centrifugal casting is of great importance, regarding to its mechanical properties. The solidification time of the casting is dependent upon the various parameters like speed ofrotation of the mold, mould wall temperature, heat transfer coefficient at the metal-mold interface, mould wall thickness, material of the mould and so on. In this paper experimental study of effect of mould wall thickness on solidification of the centrifugal casting has been discussed. As the mould wall thickness increases, due to the chilling effect, the solidification time decreases. Fine grains are observed in castings produced in thick walled mould and coarse grains are observed in thin walled moulds. Brinel Hardness of the casting was measured.

  17. COOLING METHOD OF SILUMINA CASTINGS AK15M3 AT VERTICAL CENTRIFUGAL CASTING

    Directory of Open Access Journals (Sweden)

    V. Yu. Stecenko

    2013-01-01

    Full Text Available The way of cooling of castings from silumin AK15M3 is developed at the vertical centrifugal casting, enabling to receive bimetallic blanks with high-disperse eutectic and hypereutectic microstructures and minimal allowance for machining.

  18. Numerical simulation for permanent mold centrifugal cast TiAl exhaust valve

    Institute of Scientific and Technical Information of China (English)

    SHENG Wen-bin; LI Dong

    2005-01-01

    The filling and solidification in centrifugal field, as well as the forming mechanism of off-center porosities were summarized, based on the mathematical model established for the centrifugal cast TiAl exhaust valves.The calculated results show that the centrifugal field results in the phenomenon that the flow in the valve cavity consists of forward flow and backward flow. The unsymmetrical initial temperature field causes continuous unsymmetrical variation in the following solidification, which makes the final solidified region depart from the cavity axis and then leads to the occurrence of off-center porosity. A series of optimized parameters, including the entrance velocity of 0.6 - 1.3 m/s, the rotation speed higher than 300 r/min, 80 mm or longer entrance length and 400 ℃ or higher preheated temperature of the mold, are suggested for the manufacture of permanent mold centrifugal cast TiAl exhaust valves.

  19. Filling and solidification of TiAl melt in centrifugal field

    Institute of Scientific and Technical Information of China (English)

    SHENG Wen-bin

    2006-01-01

    A model was established based on the combination of the equation of continuity,the equation of conservation of momentum and the equation of general energy to describe the filling and solidification of TiAl melt by permanent mold centrifugal casting. The model was solved numerically and the filling and solidification processes in the centrifugal field were discussed. The results indicate that the centrifugal field essentially influences the filling and solidification processes of TiAl melt. The melt will first fill the cavity along the back boundary until it reaches the end. After the end is fully filled,the whole cavity will be filled gradually by the way that free surface of the melt moves towards the entrance,hence the entrance is the last part to be filled. Furthermore,the mechanism by which internal defects can be formed in centrifugally cast TiAl components were interpreted.

  20. Rapid, low-cost prototyping of centrifugal microfluidic devices for effective implementation of various microfluidic operations

    CSIR Research Space (South Africa)

    Hugo, S

    2013-10-01

    Full Text Available The work presented here details the implementation of a centrifugal microfluidic platform – the first of its kind in South Africa – as a foundation for the development of various microfluidic operations. Microfluidic systems enable the precise...

  1. Retention of Ascorbic Acid and Solid Concentration via Centrifugal Freeze Concentration of Orange Juice

    Directory of Open Access Journals (Sweden)

    P. Orellana-Palma

    2017-01-01

    Full Text Available Freeze concentration of liquid foods produces high-quality concentrates while retaining the heat-labile compounds found in fresh samples. Centrifugal freeze concentration is a cryoconcentration method assisted by an external force, centrifugation, to enhance the separation of concentrate from the ice. When applying centrifugal freeze concentration to orange juice, after the third cryoconcentration cycle, the ascorbic acid content in the concentrate showed retention close to 70% of the initial value. After the third cycle, the solutes in the concentrate increased 4 times the initial value of the fresh sample with 70% efficiency. The color evaluation showed that the final concentrated fraction was darker than the fresh juice. The centrifugal freeze concentration in orange juice was effective for obtaining a high-quality concentrate with a higher concentration of solids and ascorbic acid retention.

  2. Centrifuge modeling of one-step outflow tests for unsaturated parameter estimations

    Directory of Open Access Journals (Sweden)

    H. Nakajima

    2006-05-01

    Full Text Available Centrifuge modeling of one-step outflow tests were carried out using a 2-m radius geotechnical centrifuge, and the cumulative outflow and transient pore pressure were measured during the tests at multiple gravity levels. Based on the scaling law of centrifuge modeling, the measurements generally showed reasonable agreement with prototype data calculated from forward simulations with input parameters determined from standard laboratory tests. The parameter optimizations were examined for three different combinations of input data sets using the test measurements. Within the gravity level examined in this study up to 40 g, the optimized unsaturated parameters compared well when accurate pore pressure measurements were included along with cumulative outflow as input data. The centrifuge modeling technique with its capability to implement variety of instrumentations under well controlled initial and boundary conditions, shortens testing time and can provide significant information for the parameter estimation procedure.

  3. Centrifuge modeling of one-step outflow tests for unsaturated parameter estimations

    Directory of Open Access Journals (Sweden)

    H. Nakajima

    2006-01-01

    Full Text Available Centrifuge modeling of one-step outflow tests were carried out using a 2-m radius geotechnical centrifuge, and the cumulative outflow and transient pore water pressure were measured during the tests at multiple gravity levels. Based on the scaling laws of centrifuge modeling, the measurements generally showed reasonable agreement with prototype data calculated from forward simulations with input parameters determined from standard laboratory tests. The parameter optimizations were examined for three different combinations of input data sets using the test measurements. Within the gravity level examined in this study up to 40g, the optimized unsaturated parameters compared well when accurate pore water pressure measurements were included along with cumulative outflow as input data. With its capability to implement variety of instrumentations under well controlled initial and boundary conditions and to shorten testing time, the centrifuge modeling technique is attractive as an alternative experimental method that provides more freedom to set inverse problem conditions for the parameter estimation.

  4. Fast centrifugal partition chromatography as a preparative-scale separation technique for citrus flavones

    Science.gov (United States)

    Fast centrifugal partition chromatography (FCPC) is a preparative-scale separations methodology based on the principles of counter current chromatography. Separations by FCPC are typically achieved with higher recoveries and with lower solvent use compared to conventional column chromatography. HSCP...

  5. The computer simulation of 3d gas dynamics in a gas centrifuge

    Science.gov (United States)

    Borman, V. D.; Bogovalov, S. V.; Borisevich, V. D.; Tronin, I. V.; Tronin, V. N.

    2016-09-01

    We argue on the basis of the results of 2D analysis of the gas flow in gas centrifuges that a reliable calculation of the circulation of the gas and gas content in the gas centrifuge is possible only in frameworks of 3D numerical simulation of gas dynamics in the gas centrifuge (hereafter GC). The group from National research nuclear university, MEPhI, has created a computer code for 3D simulation of the gas flow in GC. The results of the computer simulations of the gas flows in GC are presented. A model Iguassu centrifuge is explored for the simulations. A nonaxisymmetric gas flow is produced due to interaction of the hypersonic rotating flow with the scoops for extraction of the product and waste flows from the GC. The scoops produce shock waves penetrating into a working camera of the GC and form spiral waves there.

  6. A centrifugal microfluidic platform for point-of-care diagnostic applications

    CSIR Research Space (South Africa)

    Hugo, S

    2014-02-01

    Full Text Available -of-care health diagnostics, environmental diagnostics and chemical and biological production. Microfluidic disc design, manufacture and assembly Centrifugal microfluidic disc devices can be designed using a computer aided design (CAD) program such as Solidworks...

  7. A centrifugally actuated point-of-care testing system for the surface acoustic wave immunosensing of cardiac troponin I.

    Science.gov (United States)

    Lee, Woochang; Jung, Jaeyeon; Hahn, Young Ki; Kim, Sang Kyu; Lee, Yeolho; Lee, Joonhyung; Lee, Tae-Han; Park, Jin-Young; Seo, Hyejung; Lee, Jung Nam; Oh, Jin Ho; Choi, Youn-Suk; Lee, Soo Suk

    2013-05-07

    A fully automated point-of-care testing (POCT) system with a surface acoustic wave (SAW) immunosensor was developed for rapid and sensitive detection of cardiac troponin I (cTnI) in body fluid (plasma and whole blood). The assay, based on gold nanoparticle sandwich immunoassay and subsequent gold staining, was performed on the SAW immunosensor packaged inside a disposable microfluidic cartridge. The entire fluidic process, including plasma separation, reagent transport, metering, and mixing, was carried out by controlling the centrifugal force acting on the rotating cartridge and laser-irradiated ferrowax microvalves. On investigation of sensor response to various cTnI concentrations, the system exhibited a high performance with a detection limit of 6.7 pg mL(-1), and the coefficient of variation was less than 10% over the entire test range (10 pg mL(-1) to 25 ng mL(-1)). On comparing this POCT system with a clinically utilized system in a physical laboratory (Centaur® XP; Siemens), a correlation coefficient of 0.998 was found, validating the diagnostic capability of the SAW immunosensor.

  8. Flow Field of Metallic Fluid Acted by Electromagnetic and Centrifugal Force

    Institute of Scientific and Technical Information of China (English)

    QIU Yi-qing; LUO Zong-an; JIA Guang-lin; LIU Xiang-hua; WANG Guo-dong

    2004-01-01

    According to the principle of electromagnetism and hydrodynamics, a mathematical model of flow field for metallic fluid acted by electromagnetic and centrifugal forces was established. The calculation results showed that the relative velocity between metallic fluid layers rises and the absolute rotational velocity of metallic fluid falls with the increase of magnetic induction intensity. The increase of centrifugal revolution hardly affects the relative velocity between metallic fluid layers, but can enhance the absolute rotational velocity of metallic fluid.

  9. Faults Analysis and Diagnosis of DR J-460 Dish Centrifugal Separator's Helical Gear

    Institute of Scientific and Technical Information of China (English)

    MA Xiao-jian; GAN Xue-hui

    2004-01-01

    The main faults of dish centrifugal separator's helical gear are described in this paper. In order to diagnose the DR J-460 dish centrifugal separator correctly, the vibration is tested with a helical gear under both normal and abnormal conditions. After comparing several general methods of the gear's fault feature extraction, a new convenient and effective method is presented on the basis of analyzing the vibration spectrum under different rotary velocities.

  10. Modeling on Fluid Flow and Inclusion Motion in Centrifugal Continuous Casting Strands

    Science.gov (United States)

    Wang, Qiangqiang; Zhang, Lifeng; Sridhar, Seetharaman

    2016-08-01

    During the centrifugal continuous casting process, unreasonable casting parameters can cause violent level fluctuation, serious gas entrainment, and formation of frozen shell pieces at the meniscus. Thus, in the current study, a three-dimensional multiphase turbulent model was established to study the transport phenomena during centrifugal continuous casting process. The effects of nozzle position, casting and rotational speed on the flow pattern, centrifugal force acting on the molten steel, level fluctuation, gas entrainment, shear stress on mold wall, and motion of inclusions during centrifugal continuous casting process were investigated. Volume of Fluid model was used to simulate the molten steel-air two-phase. The level fluctuation and the gas entrainment during casting were calculated by user-developed subroutines. The trajectory of inclusions in the rotating system was calculated using the Lagrangian approach. The results show that during centrifugal continuous casting, a large amount of gas was entrained into the molten steel, and broken into bubbles of various sizes. The greater the distance to the mold wall, the smaller the centrifugal force. Rotation speed had the most important influence on the centrifugal force distribution at the side region. Angular moving angle of the nozzle with 8° and keeping the rotation speed with 60 revolutions per minute can somehow stabilize the level fluctuation. The increase of angular angle of nozzle from 8 to 18 deg and rotation speed from 40 to 80 revolutions per minute favored to decrease the total volume of entrained bubbles, while the increase of distance of nozzle moving left and casting speed had reverse effects. The trajectories of inclusions in the mold were irregular, and then rotated along the strand length. After penetrating a certain distance, the inclusions gradually moved to the center of billet and gathered there. More work, such as the heat transfer, the solidification, and the inclusions entrapment

  11. Practice of centrifugal stable isotope separation for experiments in neutrino physics

    Energy Technology Data Exchange (ETDEWEB)

    Tikhomirov, A.V. [Kurchatov Institute, Moscow (Russian Federation)

    1994-12-31

    Results of xenon 136, germanium 76 and chromium 50 enrichment with the use of centrifuge cascades are presented. The isotopes are meant for use in experiments in neutrino physics. Tens of kilograms of these isotopes have been produced in Russia, with an enrichment level of an order of magnitude or higher with respect to their natural content. Practical possibilities of using the centrifugal technique both for neutrino investigation and other applications are outlined. 2 tabs., 9 refs.

  12. DESIGN AND DYNAMICAL SIMULATION TO NEW VIBRATING CENTRIFUGE WITH WIDER FREQUENCY RANGE

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    A new type of vibrating centrifuge with wider frequency range is designed instead of the traditional one with a single frequency to improve the vibrating effect. With the aid of a new dynamical model, one simulation without considering the visco-elasticity of basis is presented, then the dynamical responses of time and frequency in different scheme are given. The computational results show that the improved vibrating centrifuge possesses a remarkably widened frequency range.

  13. Comparison of centrifuged liquid based cytology method with conventional brush cytology in oral lesions

    OpenAIRE

    Nidhi Dwivedi; Akhil Agarwal; Vineet Raj; Bina Kashyap; Shaleen Chandra

    2012-01-01

    Background: Exfoliative cytology is the study of cells that are shed or scrapped off from mucosal surfaces. Centrifuged Liquid based cytology is a modified technique employed in the present study. Aims: To compare the utility of centrifuged liquid based cytology with conventional cytology in oral lesions after staining with Papanicolaou (PAP) stain. Materials and Methods: 50 cases of oral lesions comprising of normal mucosa (n=14), hyperkeratotic lesions (n=17), ulcerated lesions (n=7) and at...

  14. Proteomic profiling of human plasma exosomes identifies PPARgamma as an exosome-associated protein.

    Science.gov (United States)

    Looze, Christopher; Yui, David; Leung, Lester; Ingham, Matthew; Kaler, Maryann; Yao, Xianglan; Wu, Wells W; Shen, Rong-Fong; Daniels, Mathew P; Levine, Stewart J

    2009-01-16

    Exosomes are nanovesicles that are released from cells as a mechanism of cell-free intercellular communication. Only a limited number of proteins have been identified from the plasma exosome proteome. Here, we developed a multi-step fractionation scheme incorporating gel exclusion chromatography, rate zonal centrifugation through continuous sucrose gradients, and high-speed centrifugation to purify exosomes from human plasma. Exosome-associated proteins were separated by SDS-PAGE and 66 proteins were identified by LC-MS/MS, which included both cellular and extracellular proteins. Furthermore, we identified and characterized peroxisome proliferator-activated receptor-gamma (PPARgamma), a nuclear receptor that regulates adipocyte differentiation and proliferation, as well as immune and inflammatory cell functions, as a novel component of plasma-derived exosomes. Given the important role of exosomes as intercellular messengers, the discovery of PPARgamma as a component of human plasma exosomes identifies a potential new pathway for the paracrine transfer of nuclear receptors.

  15. Uses of plasma in Spain.

    Science.gov (United States)

    Algora, M; Barbolla, L

    2007-12-01

    In Spain, fresh frozen plasma (FFP) currently recovered either by whole blood centrifugation or by apheresis is mainly considered as a source of plasma derivates rather than a product to be transfused. Upon this consideration, the amount of plasma transfused in the last two decades has remained stable, while the production of FFP has grown steadily during all these years. Thus, much more plasma has been derived to industry for manufacturing. Although, since 1993 a consensus conference established the clinical situation where plasma has demonstrated its efficacy, the true situation is that many indications seem not to be supported on a scientific evidence basis. Only a few studies have been performed in the last years to assess the appropriateness of these indications. We present the initial result of an ongoing survey addressed by the Madrid Blood Transfusion Centre. Based on the criteria of total amount of RBC transfused per year, large hospitals (more than 10,000 units of RBC) transfused an average of 23.87% of FFP, while medium hospitals (5000-10,000 units of RBC) used 19.5% and small ones (less than 5000) about 12.5%. It is important to point out that inside each group there were some important differences in ratio values for similar hospitals. This could indicate that much more is necessary to cope with indications. Although national figures of uses of FFP, whether in ratio or absolute terms, show a moderate consumption in comparison with published figures of other European countries, there can be no doubt that plasma overuses still seem to be present.

  16. Roller and Centrifugal Pumps: A Retrospective Comparison of Bleeding Complications in Extracorporeal Membrane Oxygenation.

    Science.gov (United States)

    Halaweish, Ihab; Cole, Adam; Cooley, Elaine; Lynch, William R; Haft, Jonathan W

    2015-01-01

    Centrifugal pumps are increasingly used for extracorporeal membrane oxygenation (ECMO) rather than roller pumps. However, shear forces induced by these types of continuousflow pumps are associated with acquired von Willebrand factor deficiency and bleeding complications. This study was undertaken to compare adverse bleeding complications with the use of centrifugal and roller pumps in patients on prolonged ECMO support. The records of all adult ECMO patients from June 2002 to 2013 were retrospectively reviewed using the University of Michigan Health System database and the Extracorporeal Life Support Organization registry, focusing on patients supported for at least 5 days. Ninety-five ECMO patients met criteria for inclusion (48 roller vs. 47 centrifugal pump). Indications included pulmonary (79%), cardiac (15%), and extracorporeal cardiopulmonary resuscitation (6%), without significant difference between the two groups. Despite lower heparin anticoagulation (10.9 vs. 13.7 IU/kg/hr) with centrifugal pumps, there was a higher incidence of nonsurgical bleeding (gastrointestinal, pulmonary, and neurological) in centrifugal pump patients (26.1 vs. 9.0 events/1,000 patient-days, p = 0.024). In conclusion, in our historical comparison, despite reduced anticoagulation, ECMO support using centrifugal pumps was associated with a higher incidence of nonsurgical bleeding. The mechanisms behind this are multifactorial and require further investigation.

  17. 离心静电纺丝的模式%Modes of Centrifugal Electrospinning

    Institute of Scientific and Technical Information of China (English)

    彭浩; 张敬男; 李秀红; 宋庆松; 刘勇

    2015-01-01

    The mechanism and characteristics of centrifugal electrospinning were introduced. According to the different spinning materials,the centrifugal electrospinning was devided into solution centrifugal electrospinning and melt centrifugal electrospinning. The devices of the two type centrifugal electrospinning were divided into two types:conventional mode and revised mode. The structural characteristics,the advantages and disadvantages of all kinds of devices were summarized. The problems of the centrifugal electrospinning were pointed out and some advices for improvement were proposed.%介绍了离心静电纺丝的原理及特点,根据纺丝介质的不同,将离心静电纺丝分为溶液离心静电纺丝和熔体离心静电纺丝两类,并将这两类纺丝方法的装置分为常规模式和改进模式,总结了各种装置的结构特征、纺丝的优缺点。指出了现阶段离心静电纺丝存在的一些问题,并提出了相应的改进方案。

  18. The Effect of Moment of Inertia on the Liquids in Centrifugal Microfluidics

    Directory of Open Access Journals (Sweden)

    Esmail Pishbin

    2016-12-01

    Full Text Available The flow of liquids in centrifugal microfluidics is unidirectional and dominated by centrifugal and Coriolis forces (i.e., effective only at T-junctions. Developing mechanisms and discovering efficient techniques to propel liquids in any direction other than the direction of the centrifugal force has been the subject of a large number of studies. The capillary force attained by specific surface treatments, pneumatic energy, active and passive flow reciprocation and Euler force have been previously introduced in order to manipulate the liquid flow and push it against the centrifugal force. Here, as a new method, the moment of inertia of the liquid inside a chamber in a centrifugal microfluidic platform is employed to manipulate the flow and propel the liquid passively towards the disc center. Furthermore, the effect of the moment of inertia on the liquid in a rectangular chamber is evaluated, both in theory and experiments, and the optimum geometry is defined. As an application of the introduced method, the moment of inertia of the liquid is used in order to mix two different dyed deionized (DI waters; the mixing efficiency is evaluated and compared to similar mixing techniques. The results show the potential of the presented method for pumping liquids radially inward with relatively high flow rates (up to 23 mm3/s and also efficient mixing in centrifugal microfluidic platforms.

  19. Feasibility of a Short-Arm Centrifuge for Mouse Hypergravity Experiments

    Science.gov (United States)

    Morita, Hironobu; Obata, Koji; Abe, Chikara; Shiba, Dai; Shirakawa, Masaki; Kudo, Takashi; Takahashi, Satoru

    2015-01-01

    To elucidate the pure impact of microgravity on small mammals despite uncontrolled factors that exist in the International Space Station, it is necessary to construct a 1 g environment in space. The Japan Aerospace Exploration Agency has developed a novel mouse habitat cage unit that can be installed in the Cell Biology Experiment Facility in the Kibo module of the International Space Station. The Cell Biology Experiment Facility has a short-arm centrifuge to produce artificial 1 g gravity in space for mouse experiments. However, the gravitational gradient formed inside the rearing cage is larger when the radius of gyration is shorter; this may have some impact on mice. Accordingly, biological responses to hypergravity induced by a short-arm centrifuge were examined and compared with those induced by a long-arm centrifuge. Hypergravity induced a significant Fos expression in the central nervous system, a suppression of body mass growth, an acute and transient reduction in food intake, and impaired vestibulomotor coordination. There was no difference in these responses between mice raised in a short-arm centrifuge and those in a long-arm centrifuge. These results demonstrate the feasibility of using a short-arm centrifuge for mouse experiments. PMID:26221724

  20. Feasibility of a Short-Arm Centrifuge for Mouse Hypergravity Experiments.

    Directory of Open Access Journals (Sweden)

    Hironobu Morita

    Full Text Available To elucidate the pure impact of microgravity on small mammals despite uncontrolled factors that exist in the International Space Station, it is necessary to construct a 1 g environment in space. The Japan Aerospace Exploration Agency has developed a novel mouse habitat cage unit that can be installed in the Cell Biology Experiment Facility in the Kibo module of the International Space Station. The Cell Biology Experiment Facility has a short-arm centrifuge to produce artificial 1 g gravity in space for mouse experiments. However, the gravitational gradient formed inside the rearing cage is larger when the radius of gyration is shorter; this may have some impact on mice. Accordingly, biological responses to hypergravity induced by a short-arm centrifuge were examined and compared with those induced by a long-arm centrifuge. Hypergravity induced a significant Fos expression in the central nervous system, a suppression of body mass growth, an acute and transient reduction in food intake, and impaired vestibulomotor coordination. There was no difference in these responses between mice raised in a short-arm centrifuge and those in a long-arm centrifuge. These results demonstrate the feasibility of using a short-arm centrifuge for mouse experiments.

  1. New methods and media for the centrifugation of honey bee (Hymenoptera: Apidae) drone semen.

    Science.gov (United States)

    Wegener, Jakob; May, Tanja; Kamp, Günter; Bienefeld, Kaspar

    2014-02-01

    Centrifugation of Apis mellifera L. drone semen is a necessary step in the homogenization of semen pools for the enlargement of the effective breeding population, as well as in the collection of semen by the so-called washing technique. It is also of interest for the removal of cryoprotectants after cryopreservation. The adoption of methods involving semen centrifugation has been hampered by their damaging effect to sperm. Here, we tested four new diluents as well as three additives (catalase, hen egg yolk, and a protease inhibitor), using sperm motility and dual fluorescent staining as indicators of semen quality. Three of the new diluents significantly reduced motility losses after centrifugation, as compared with the literature standard. Values of motility and propidium iodide negativity obtained with two of these diluents were not different from those measured with untreated semen. The least damaging diluent, a citrate-HEPES buffer containing trehalose, was then tested in an insemination experiment with centrifuged semen. Most queens receiving this semen produced normal brood, and the number of sperm reaching the storage organ of the queen was not significantly different from that in queens receiving untreated semen. These results could improve the acceptance of techniques involving the centrifugation of drone semen. The diluent used in the insemination experiment could also serve as semen extender for applications not involving centrifugation.

  2. Isolation of Intact Mitochondria from Skeletal Muscle by Differential Centrifugation for High-resolution Respirometry Measurements.

    Science.gov (United States)

    Djafarzadeh, Siamak; Jakob, Stephan Mathias

    2017-03-08

    Mitochondria are involved in cellular energy metabolism and use oxygen to produce energy in the form of adenosine triphosphate (ATP). Differential centrifugation at low- and high-speed is commonly used to isolate mitochondria from tissues and cultured cells. Crude mitochondrial fractions obtained by differential centrifugation are used for respirometry measurements. The differential centrifugation technique is based on the separation of organelles according to their size and sedimentation velocity. The isolation of mitochondria is performed immediately after tissue harvesting. The tissue is immersed in an ice-cold homogenization medium, minced using scissors and homogenized in a glass homogenizer with a loose-fitting pestle. The differential centrifugation technique is efficient, fast and inexpensive and the mitochondria obtained by differential centrifugation are pure enough for respirometry assays. Some of the limitations and disadvantages of isolated mitochondria, based on differential centrifugation, are that the mitochondria can be damaged during the homogenization and isolation procedure and that large amounts of the tissue biopsy or cultured cells are required for the mitochondrial isolation.

  3. Active pneumatic control of centrifugal microfluidic flows for lab-on-a-chip applications.

    Science.gov (United States)

    Clime, Liviu; Brassard, Daniel; Geissler, Matthias; Veres, Teodor

    2015-06-01

    This paper reports a novel method of controlling liquid motion on a centrifugal microfluidic platform based on the integration of a regulated pressure pump and a programmable electromechanical valving system. We demonstrate accurate control over the displacement of liquids within the system by pressurizing simultaneously multiple ports of the microfluidic device while the platform is rotating at high speed. Compared to classical centrifugal microfluidic platforms where liquids are solely driven by centrifugal and capillary forces, the method presented herein adds a new degree of freedom for fluidic manipulation, which represents a paradigm change in centrifugal microfluidics. We first demonstrate how various core microfluidic functions such as valving, switching, and reverse pumping (i.e., against the centrifugal field) can be easily achieved by programming the pressures applied at dedicated access ports of the microfluidic device. We then show, for the first time, that the combination of centrifugal force and active pneumatic pumping offers the possibility of mixing fluids rapidly (~0.1 s) and efficiently based on the creation of air bubbles at the bottom of a microfluidic reservoir. Finally, the suitability of the developed platform for performing complex bioanalytical assays in an automated fashion is demonstrated in a DNA harvesting experiment where recovery rates of about 70% were systematically achieved. The proposed concept offers the interesting prospect to decouple basic microfluidic functions from specific material properties, channel dimensions and fabrication tolerances, surface treatments, or on-chip active components, thus promoting integration of complex assays on simple and low-cost microfluidic cartridges.

  4. Polymethylmethacrylate/Polyacrylonitrile Membranes via Centrifugal Spinning as Separator in Li-Ion Batteries

    Directory of Open Access Journals (Sweden)

    Meltem Yanilmaz

    2015-04-01

    Full Text Available Electrospun nanofiber membranes have been extensively studied as separators in Li-ion batteries due to their large porosity, unique pore structure, and high electrolyte uptake. However, the electrospinning process has some serious drawbacks, such as low spinning rate and high production cost. The centrifugal spinning technique can be used as a fast, cost-effective and safe technique to fabricate high-performance fiber-based separators. In this work, polymethylmethacrylate (PMMA/polyacrylonitrile (PAN membranes with different blend ratios were produced via centrifugal spinning and characterized by using different electrochemical techniques for use as separators in Li-ion batteries. Compared with commercial microporous polyolefin membrane, centrifugally-spun PMMA/PAN membranes had larger ionic conductivity, higher electrochemical oxidation limit, and lower interfacial resistance with lithium. Centrifugally-spun PMMA/PAN membrane separators were assembled into Li/LiFePO4 cells and these cells delivered high capacities and exhibited good cycling performance at room temperature. In addition, cells using centrifugally-spun PMMA/PAN membrane separators showed superior C-rate performance compared to those using microporous polypropylene (PP membranes. It is, therefore, demonstrated that centrifugally-spun PMMA/PAN membranes are promising separator candidate for high-performance Li-ion batteries.

  5. A high-efficiency superhydrophobic plasma separator.

    Science.gov (United States)

    Liu, Changchun; Liao, Shih-Chuan; Song, Jinzhao; Mauk, Michael G; Li, Xuanwen; Wu, Gaoxiang; Ge, Dengteng; Greenberg, Robert M; Yang, Shu; Bau, Haim H

    2016-02-01

    To meet stringent limit-of-detection specifications for low abundance target molecules, a relatively large volume of plasma is needed for many blood-based clinical diagnostics. Conventional centrifugation methods for plasma separation are not suitable for on-site testing or bedside diagnostics. Here, we report a simple, yet high-efficiency, clamshell-style, superhydrophobic plasma separator that is capable of separating a relatively large volume of plasma from several hundred microliters of whole blood (finger-prick blood volume). The plasma separator consists of a superhydrophobic top cover with a separation membrane and a superhydrophobic bottom substrate. Unlike previously reported membrane-based plasma separators, the separation membrane in our device is positioned at the top of the sandwiched whole blood film to increase the membrane separation capacity and plasma yield. In addition, the device's superhydrophobic characteristics (i) facilitates the formation of well-defined, contracted, thin blood film with a high contact angle; (ii) minimizes biomolecular adhesion to surfaces; (iii) increases blood clotting time; and (iv) reduces blood cell hemolysis. The device demonstrated a "blood in-plasma out" capability, consistently extracting 65 ± 21.5 μL of plasma from 200 μL of whole blood in less than 10 min without electrical power. The device was used to separate plasma from Schistosoma mansoni genomic DNA-spiked whole blood with a recovery efficiency of >84.5 ± 25.8%. The S. mansoni genomic DNA in the separated plasma was successfully tested on our custom-made microfluidic chip by using loop mediated isothermal amplification (LAMP) method.

  6. Direct digital manufacturing of autonomous centrifugal microfluidic device

    Science.gov (United States)

    Ukita, Yoshiaki; Takamura, Yuzuru; Utsumi, Yuichi

    2016-06-01

    This paper presents strategies that attempt to solve two key problems facing the commercialization of microfluidics: cost reduction in microfluidic chip manufacturing and microfluidic device driver development. To reduce the cost of microfluidic chip manufacturing, we propose to use of three-dimensional (3D) printers for direct digital manufacturing (DDM). An evaluation of 3D micro-scale structure printing using several 3D printers is reported, and some of the technical issues to be addressed in the future are suggested. To evaluate micro-scale printing, three types of 3D printers, with the ability to print structures on the scale of several hundred meters, were selected by first screening six 3D printers. Line and space patterns with line widths of 100-500 µm and an aspect ratio of one were printed and evaluated. The estimated critical dimension was around 200 µm. The manufacturing of a monolithic microfluidic chip with embedded channels was also demonstrated. Monolithic microfluidic chips with embedded microchannels having 500 × 500 and 250 × 250 µm2 cross sections and 2-20 mm lengths were printed, and the fidelity of the channel shape, residual supporting material, and flow of liquid water were evaluated. The liquid flow evaluation showed that liquid water could flow through all of the microchannels with the 500 × 500 µm2 cross section, whereas this was not possible through some of the channels with the 250 × 250 µm2 cross section because of the residual resin or supporting material. To reduce the device-driver cost, we propose to use of the centrifugal microfluidic concept. An autonomous microfluidic device that could implement sequential flow control under a steadily rotating condition was printed. Four-step flow injection under a steadily rotating condition at 1500 rpm was successfully demonstrated without any external triggering such as changing the rotational speed.

  7. Development of centrifugal casting high speed steel rolls

    Institute of Scientific and Technical Information of China (English)

    Hanguang Fu; Aimin Zhao; Jiandong Xing

    2003-01-01

    The present study aims at developing the high speed steel (HSS) as roll materials to replace the traditional roll materials such as the alloy cast iron and powder metallurgical (PM) hard alloy. The HSS roll billet was formed by centrifugal casting, and the billet was rough machined after soften annealing heat treatment, then it was quenched and tempered to get suitable hardness and toughness. After that the HSS roll was finish machined to the final dimension of φ285 mm in the outer diameter, φ160 mm in the inner diameter and 120 mm in width and its surface hardness was tested. Finally the HSS roll was used in high speed wire rod mill. The test results show that a high and homogeneous hardness can obtain on the work surface of HSS rolls, the surface hardness is 63-65HRC and its variation is smaller than 2HRC. The impact toughness of this kind of HSS is about 16 J/cra2. The results of on-line service investigation in high speed wire rod mill indicate that the HSS rolls have excellent wear resistance, the steel rolling quantity per mm of HSS rolls is 3120 t, the service life-span of HSS rolls is 4 times longer than that of high chromium cast iron rolls and it is close to that of the PM hard alloy rolls. The manufacturing burden of HSS rolls is obviously lower than that of the PM hard alloy rolls, it is only 25% of that of the PM hard alloy rolls.

  8. Defining the needs for gas centrifuge enrichment plants advanced safeguards

    Energy Technology Data Exchange (ETDEWEB)

    Boyer, Brian David [Los Alamos National Laboratory; Erpenbeck, Heather H [Los Alamos National Laboratory; Miller, Karen A [Los Alamos National Laboratory; Swinhoe, Martyn T [Los Alamos National Laboratory; Ianakiev, Kiril [Los Alamos National Laboratory; Marlow, Johnna B [Los Alamos National Laboratory

    2010-04-05

    Current safeguards approaches used by the International Atomic Energy Agency (IAEA) at gas centrifuge enrichment plants (GCEPs) need enhancement in order to verify declared low-enriched (LEU) production, detect undeclared LEU production and detect highly enriched uranium (HEU) production with adequate detection probability using nondestructive assay (NDA) techniques. At present inspectors use attended systems, systems needing the presence of an inspector for operation, during inspections to verify the mass and {sup 235}U enrichment of declared UF{sub 6} containers used in the process of enrichment at GCEPs. In verifying declared LEU production, the inspectors also take samples for off-site destructive assay (DA) which provide accurate data, with 0.1% to 0.5% measurement uncertainty, on the enrichment of the UF{sub 6} feed, tails, and product. However, taking samples of UF{sub 6} for off-site analysis is a much more labor and resource intensive exercise for the operator and inspector. Furthermore, the operator must ship the samples off-site to the IAEA laboratory which delays the timeliness of results and interruptions to the continuity of knowledge (CofK) of the samples during their storage and transit. This paper contains an analysis of possible improvements in unattended and attended NDA systems such as process monitoring and possible on-site analysis of DA samples that could reduce the uncertainty of the inspector's measurements and provide more effective and efficient IAEA GCEPs safeguards. We also introduce examples advanced safeguards systems that could be assembled for unattended operation.

  9. Centrifugal contactor operations for UREX process flowsheet. An update

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Candido [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, George F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2014-08-01

    The uranium extraction (UREX) process separates uranium, technetium, and a fraction of the iodine from the other components of the irradiated fuel in nitric acid solution. In May 2012, the time, material, and footprint requirements for treatment of 260 L batches of a solution containing 130 g-U/L were evaluated for two commercial annular centrifugal contactors from CINC Industries. These calculated values were based on the expected volume and concentration of fuel arising from treatment of a single target solution vessel (TSV). The general conclusions of that report were that a CINC V-2 contactor would occupy a footprint of 3.2 m 2 (0.25 m x 15 m) if each stage required twice the nominal footprint of an individual stage, and approximately 1,131 minutes or nearly 19 hours is required to process all of the feed solution. A CINC V-5 would require approximately 9.9 m 2 (0.4 m x 25 m) of floor space but would require only 182 minutes or ~ 3 hours to process the spent target solution. Subsequent comparison with the Modular Caustic Side Solvent Extraction Unit (MCU) at Savannah River Site (SRS) in October 2013 suggested that a more compact arrangement is feasible, and the linear dimension for the CINC V-5 may be reduced to about 8 m; a comparable reduction for the CINC V-2 yields a length of 5 m. That report also described an intermediate-scale (10 cm) contactor design developed by Argonne in the early 1980s that would better align with the SHINE operations as they stood in May 2012. In this report, we revisit the previous evaluation of contactor operations after discussions with CINC Industries and analysis of the SHINE process flow diagrams for the cleanup of the TSV, which were not available at the time of the first assessment.

  10. Principles of separation: indications and therapeutic targets for plasma exchange.

    Science.gov (United States)

    Williams, Mark E; Balogun, Rasheed A

    2014-01-01

    Extracorporeal "blood purification," mainly in the form of hemodialysis has been a major portion of the clinical activity of many nephrologists for the past 5 decades. A possibly older procedure, therapeutic plasma exchange, separates and then removes plasma as a method of removing pathogenic material from the patient. In contrast to hemodialysis, therapeutic plasma exchange preferentially removes biologic substances of high molecular weight such as autoantibodies or alloantibodies, antigen-antibody complexes, and Ig paraproteins. These molecular targets may be cleared through two alternative procedures: centrifugal separation and membrane separation. This review presents operational features of each procedure, with relevance to the nephrologist. Kinetics of removal of these plasma constituents are based on the principles of separation by the apheresis technique and by features specific to each molecular target, including their production and compartmentalization in the body. Molecular targets for common renal conditions requiring therapeutic plasma exchange are also discussed in detail.

  11. [Updated detection of the function of sperm plasma membrane].

    Science.gov (United States)

    Zhou, Xin; Xia, Xin-Yi; Huang, Yu-Feng

    2010-08-01

    The sperm plasma membrane is rich in polyunsaturated fatty acids and a variety of proteins, and its function is associated with sperm capacitation, acrosome reaction and sperm-egg fusion. Sperm fertilizability can be predicted by detecting the function of the sperm plasma membrane, which is performed mainly with the following five techniques: sperm hypoosmotic swelling test, Eosin gamma water test, sperm membrane lipid peroxidation determination, seminal plasma superoxide dismutase determination, and flow cytometry. The evaluation of the function of sperm plasma membrane can be applied in detecting semen quality, selecting semen centrifugation, assessing the quality and fertilizability of sex-sorted sperm, improving cryopreservation, and guiding the optimization of intracytoplasmic sperm injection. This review presents an update on the principles, methods and steps of the detection of sperm plasma membrane function, as well as an overview of its status quo and application.

  12. Neuro-Motor Responses to Daily Centrifugation in Bed-Rested Subjects

    Science.gov (United States)

    Reschke, Millard F.; Somers, Jeffery T.; Krnavek, Jody; Fisher, Elizibeth; Ford, George; Paloski, William H.

    2007-01-01

    It is well known from numerous space flight studies that exposure to micro-g produces both morphological and neural adaptations in the major postural muscles. However, the characteristics and mechanism of these changes, particularly when it may involve the central nervous system are not defined. Furthermore, it is not known what role unloading of the muscular system may have on central changes in sensorimotor function or if centrifugation along the +Gz direction (long body axis) can mitigate both the peripheral changes in muscle function and modification of the central changes in sensorimotor adaptation to the near weightless environment of space flight. The purpose of this specific effort was, therefore, to investigate the efficacy of artificial gravity (AG) as a method for maintaining sensorimotor function in micro-g. Eight male subjects were exposed to daily 1 hr centrifugation during a 21 day 6 degree head-down bed rest study. Seven controls were placed on the centrifuge without rotation. The radius and angular velocity of the centrifuge were adjusted such that each subject experienced a centripetal acceleration of 2.5g at the feet, and approximately 1.0g at the heart. Both the tendon (MSR) and functional stretch reflexes (FSR) were collected using an 80 lb. ft. servomotor controlled via position feedback to provide a dorsiflexion step input to elicit the MSR, and the same step input with a built in 3 sec hold to evoke the FSR. EMG data were obtained from the triceps surae. Supplementary torque, velocity and position data were collected with the EMG responses. All data were digitized and sampled at 4 kHz. Only the MSR data has been analyzed at this time, and preliminary results suggest that those subjects exposed to active centrifugation (treatment group) show only minor changes in MSR peak latency times, either as a function of time spent in bed rest or exposure to centrifugation, while the control subjects show delays in the MSR peak latencies that are

  13. Metabolomic Quality Assessment of EDTA Plasma and Serum Samples.

    Science.gov (United States)

    Malm, Linus; Tybring, Gunnel; Moritz, Thomas; Landin, Britta; Galli, Joakim

    2016-10-01

    Handling and processing of blood can significantly alter the molecular composition and consistency of biobank samples and can have a major impact on the identification of biomarkers. It is thus crucial to identify tools to determine the quality of samples to be used in biomarker discovery studies. In this study, a non-targeted gas chromatography/time-of-flight mass spectrometry (GC-TOFMS) metabolomic strategy was used with the aim of identifying quality markers for serum and plasma biobank collections lacking proper documentation of preanalytical handling. The effect of postcentrifugation delay was examined in serum stored in tubes with gel separation plugs and ethylenediaminetetraacetic acid (EDTA) plasma in tubes with or without gel separation plugs. The change in metabolic pattern was negligible in all sample types processed within 3 hours after centrifugation regardless of whether the samples were kept at 4°C or 22°C. After 8 and 24 hours postcentrifugation delay before aliquoting, there was a pronounced increase in the number of affected metabolites, as well as in the magnitude of the observed changes. No protective effect on the metabolites was observed in gel-separated EDTA plasma samples. In a separate series of experiments, lactate and glucose levels were determined in plasma to estimate the effect of precentrifugation delay. This separate experiment indicates that the lactate to glucose ratio may serve as a marker to identify samples with delayed time to centrifugation. Although our data from the untargeted GC-TOFMS analysis did not identify any specific markers, we conclude that plasma and serum metabolic profiles remain quite stable when plasma and serum are centrifuged and separated from the blood cells within 3 hours.

  14. Combining ergometer exercise and artificial gravity in a compact-radius centrifuge

    Science.gov (United States)

    Diaz, Ana; Trigg, Chris; Young, Laurence R.

    2015-08-01

    Humans experience physiological deconditioning during space missions, primarily attributable to weightlessness. Some of these adverse consequences include bone loss, muscle atrophy, sensory-motor deconditioning, and cardiovascular alteration, which may lead to orthostatic intolerance when astronauts return to Earth. Artificial gravity could provide a comprehensive countermeasure capable of challenging all the physiological systems at once, particularly if combined with exercise, thereby maintaining overall health during extended exposure to weightlessness. A new Compact Radius Centrifuge (CRC) platform was designed and built on the existing Short Radius Centrifuge (SRC) at the Massachusetts Institute of Technology (MIT). The centrifuge has been constrained to a radius of 1.4 m, the upper radial limit for a centrifuge to fit within an International Space Station (ISS) module without extensive structural alterations. In addition, a cycle ergometer has been added for exercise during centrifugation. The CRC now includes sensors of foot forces, cardiovascular parameters, and leg muscle electromyography. An initial human experiment was conducted on 12 subjects to analyze the effects of different artificial gravity levels (0 g, 1 g, and 1.4 g, measured at the feet) and ergometer exercise intensities (25 W warm-up, 50 W moderate and 100 W vigorous) on the musculoskeletal function as well as motion sickness and comfort. Foot forces were measured during the centrifuge runs, and subjective comfort and motion sickness data were gathered after each session. Preliminary results indicate that ergometer exercise on a centrifuge may be effective in improving musculoskeletal function. The combination is well tolerated and motion sickness is minimal. The MIT CRC is a novel platform for future studies of exercise combined with artificial gravity. This combination may be effective as a countermeasure to space physiological deconditioning.

  15. Hypolipidemic activities of xanthorrhizol purified from centrifugal TLC.

    Science.gov (United States)

    Oon, Seok Fang; Nallappan, Meenakshii; Kassim, Nur Kartinee; Shohaimi, Shamarina; Sa'ariwijaya, Mohd Shazrul Fazry; Tee, Thiam Tsui; Cheah, Yew Hoong

    2016-09-23

    Hyperlipidemia is defined as the presence of either hypertriglyceridemia or hypercholesterolemia, which could cause atherosclerosis. Although hyperlipidemia can be treated by hypolipidemic drugs, they are limited due to lack of effectiveness and safety. Previous studies demonstrated that xanthorrhizol (XNT) isolated from Curcuma xanthorrhizza Roxb. reduced the levels of free fatty acid and triglyceride in vivo. However, its ability to inhibit cholesterol uptake in HT29 colon cells and adipogenesis in 3T3-L1 cells are yet to be reported. In this study, XNT purified from centrifugal TLC demonstrated 98.3% purity, indicating it could be an alternative purification method. The IC50 values of XNT were 30.81 ± 0.78 μg/mL in HT29 cells and 35.07 ± 0.24 μg/mL in 3T3-L1 adipocytes, respectively. Cholesterol uptake inhibition study using HT29 colon cells showed that XNT (15 μg/mL) significantly inhibited the fluorescent cholesterol analogue NBD uptake by up to 27 ± 3.1% relative to control. On the other hand, higher concentration of XNT (50 μg/mL) significantly suppressed the growth of 3T3-L1 adipocytes (5.9 ± 0.58%) compared to 3T3-L1 preadipocytes (81.31 ± 0.55%). XNT was found to impede adipogenesis of 3T3-L1 adipocytes in a dose-dependent manner from 3.125 to 12.5 μg/mL, where 12.5 μg/mL significantly suppressed 36.13 ± 2.1% of lipid accumulation. We postulate that inhibition of cholesterol uptake, adipogenesis, preadipocyte and adipocyte number may be utilized as treatment modalities to reduce the prevalence of lipidemia. To conclude, XNT could be a potential hypolipidemic agent to improve cardiovascular health in the future. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Plasma Antenna

    OpenAIRE

    N M Vijay

    2014-01-01

    The fundamental base of plasma antenna is the use of an ionized medium as a conductor. The plasma antenna is a radiofrequency antenna formed by a plasma columns, Filaments or sheets, which are excited by a surface wave. The relevance of this device is how rapidly it can be turned on and off, only applying an electrical pulse. Besides its wide carrier frequency, the great directivity and controllable antenna shape. Otherwise a disadvantage is that it needs energy to be ionized....

  17. Effects of the number of inducer blades on the anti-cavitation characteristics and external performance of a centrifugal pump

    Energy Technology Data Exchange (ETDEWEB)

    Guo, XiaoMei; Shi, GaoPing [Zhejiang University of Water Resources and Electric Power, Hangzhou (China); Zhu, ZuChao; Cui, BaoLing [Zhejiang Sci-Tech University, Hangzhou (China)

    2016-07-15

    Installing an inducer upstream of the main impeller is an effective approach for improving the anti-cavitation performance of a high speed centrifugal pump. For a high-speed centrifugal pump with an inducer, the number of inducer blades can affect its internal flow and external performance. We studied the manner in which the number of inducer blades can affect the anti-cavitation characteristics and external performance of a centrifugal pump. We first use the Rayleigh-Plesset equation and the mixture model to simulate the vapor liquid flow in a centrifugal pump with an inducer, and then predict its external performance. Finally, we tested the external performance of a centrifugal pump with 2-, 3- and 4-bladed inducers, respectively. The results show that the simulations of external performance in a centrifugal pump are in accordance with our experiments. Based on this, we obtained vapor volume fraction distributions for the inducer, the impeller, and in the corresponding whole flow parts. We discovered that the vapor volume fraction of a centrifugal pump with a 3- bladed inducer is less than that of a centrifugal pump with 2- or 4-bladed inducers, which means that a centrifugal pump with a 3-bladed inducer has a better external and anti-cavitation performance.

  18. Centrifugal separation for miscible solutions: Fundamentals and applications to separation of molten salt nuclear material

    Science.gov (United States)

    Li, Ning; Camassa, Roberto; Ecke, Robert E.; Venneri, Francesco

    1995-09-01

    We report on the physical separation of dilute solutions using centrifugal techniques. We use numerical simulations of the diffusion and sedimentation dynamics of centrifugation to model the approach to an equilibrium concentration profile. We verify experimentally the equilibrium profiles for aqueous solutions of different salts under rotation at 25000 rpm corresponding to centrifugal accelerations of about 57,000 g and 75,000 g in two different commercial centrifuges. These measurements provide ratios of sedimentation and diffusion coefficients. We show experimental results for the dynamics of separation that confirm the predictions of the theoretical model. We also measure the mass diffusion coefficient for several solutions. Although the relaxation to equilibrium is long, we have determined a method for efficiently extracting enriched components from a ternary mixture based on fast dynamics at early times. These dynamics are modeled in numerical simulations with realistic fluid parameters. Based on these studies we show that a multistage centrifugal separation process could provide efficient physical separation of actinides and fission products from a molten-salt solution in proposed transmutation/energy-production systems. We consider technical issues in the design of such a separation system.

  19. Robust Design Optimization Method for Centrifugal Impellers under Surface Roughness Uncertainties Due to Blade Fouling

    Institute of Scientific and Technical Information of China (English)

    JU Yaping; ZHANG Chuhua

    2016-01-01

    Blade fouling has been proved to be a great threat to compressor performance in operating stage. The current researches on fouling-induced performance degradations of centrifugal compressors are based mainly on simplified roughness models without taking into account the realistic factors such as spatial non-uniformity and randomness of the fouling-induced surface roughness. Moreover, little attention has been paid to the robust design optimization of centrifugal compressor impellers with considerations of blade fouling. In this paper, a multi-objective robust design optimization method is developed for centrifugal impellers under surface roughness uncertainties due to blade fouling. A three-dimensional surface roughness map is proposed to describe the nonuniformity and randomness of realistic fouling accumulations on blades. To lower computational cost in robust design optimization, the support vector regression (SVR) metamodel is combined with the Monte Carlo simulation (MCS) method to conduct the uncertainty analysis of fouled impeller performance. The analyzed results show that the critical fouled region associated with impeller performance degradations lies at the leading edge of blade tip. The SVR metamodel has been proved to be an efficient and accurate means in the detection of impeller performance variations caused by roughness uncertainties. After design optimization, the robust optimal design is found to be more efficient and less sensitive to fouling uncertainties while maintaining good impeller performance in the clean condition. This research proposes a systematic design optimization method for centrifugal compressors with considerations of blade fouling, providing a practical guidance to the design of advanced centrifugal compressors.

  20. Bone growth and composition in weanling and mature rats exposed to chronic centrifugation

    Science.gov (United States)

    Keil, L. C.; Evans, J. W.

    1982-01-01

    The primary objective of the study is to determine the effect of continuous exposure to hypergravity on the development and composition of weight-bearing bone. The experimental results are seen to suggest that many, if not all, of the changes observed in bone growth and composition derive from the retarded growth rate of the centrifuged rats. Both centrifuged weanling and mature rats exhibit a significant reduction in femur length and mass. The changes in femur size are more apparent in the weanlings since they are exposed to hypergravity during their most rapid phase of skeletal development. In addition to a slower growth rate, the body mass of the mature and weanling animals is reduced even further by the depletion of body fat. The rapid loss of body fat observed in rats and mice during centrifugation, it is found, can produce a prompt and significant rise in relative femur mass after two weeks of exposure. After adaptation to centrifugation, however, relative femur mass is similar to that of controls at four and eight weeks. At 18 weeks, the centrifuged rats again exhibit an increase in relative femur mass. It is thought that this increase in relative femur mass may be generated by the difference in fat deposition between the 1-G controls and the high-G rats.

  1. Prediction and Reduction of Aerodynamic Noise of the Multiblade Centrifugal Fan

    Directory of Open Access Journals (Sweden)

    Shuiqing Zhou

    2014-08-01

    Full Text Available An aerodynamic and aeroacoustic investigation of the multiblade centrifugal fan is proposed in this paper, and a hybrid technique of combining flow field calculation and acoustic analysis is applied to solve the aeroacoustic problem of multiblade centrifugal fan. The unsteady flow field of the multiblade centrifugal fan is predicted by solving the incompressible Reynolds-averaged Navier-Stokes (RANS equations with conventional computing techniques for fluid dynamics. The principal noise source induced is extracted from the calculation of the flow field by using acoustic principles, and the modeled sources on inner and outer surfaces of the volute are calculated with multiregional boundary element method (BEM. Through qualitative analysis, the sound pressure amplitude distribution of the multiblade centrifugal fan in near field is given and the sound pressure level (SPL spectrum diagram of monitoring points in far field is obtained. Based on the analysis results, the volute tongue structure is adjusted and then a low-noise design for the centrifugal fan is proposed. The comparison of noise tests shows the noise reduction of improved fan model is more obvious, which is in good agreement with the prediction using the hybrid techniques.

  2. Influence of recovery method and centrifugation on epididymal sperm from collared peccaries (Pecari tajacu Linnaeus, 1758).

    Science.gov (United States)

    Bezerra, José Artur Brilhante; da Silva, Andréia Maria; Peixoto, Gislayne Christianne Xavier; da Silva, Mariana de Araújo; Franco de Oliveira, Moacir; Silva, Alexandre Rodrigues

    2014-05-01

    In order to establish protocols for gamete recovery from accidentally killed wild animals, or to take advantage of those slaughtered by captive breeders, we assess the influence of two methods on the recovery of epididymal sperm from collared peccaries, and verify the effect of centrifugation on such gametes. Genitalia from nine animals were used. For each animal, one epididymis was processed by flotation and the other was processed by retrograde flushing, both using a buffered media based on Tris. Following recovery, sperm were evaluated for motility, vigor, viability, functional membrane integrity, and morphology. A 1-mL aliquot of each sample was centrifuged, the supernatant removed, and the pellet suspended and evaluated as fresh samples. The sperm characteristics did not differ between the samples collected by flotation or retrograde flushing (P < 0.05). Centrifugation promoted an increase in head and tail defects, thus reducing the percentage of viable sperm (P < 0.05). No other parameter assessed for both methods was affected by centrifugation. In conclusion, epididymal sperm from collared peccaries can be efficiently collected through flotation or retrograde flushing, but not when either is followed by centrifugation.

  3. Determination of the Heat Transfer Coefficient at the Metal-Mold Interface During Centrifugal Casting

    Science.gov (United States)

    Vacca, Santiago; Martorano, Marcelo A.; Heringer, Romulo; Boccalini, Mário

    2015-05-01

    The heat transfer coefficient at the metal-mold interface ( h MM) has been determined for the first time during the centrifugal casting of a Fe-C alloy tube using the inverse solution method. To apply this method, a centrifugal casting experiment was carried out to measure cooling curves within the tube wall under a mold rotation speed of 900 rpm, imposing a centrifugal force 106 times as large as the gravity force (106 G). As part of the solution method, a comprehensive heat transfer model of the centrifugal casting was also developed and coupled to an optimization algorithm. Finally, the evolution of h MM with time that gives the minimum squared error between measured and calculated cooling curves was obtained. The determined h MM is approximately 870 W m-2 K-1 immediately after melt pouring, decreasing to about 50 W m-2 K-1 when the average temperature of the tube is ~973 K (700 °C), after the end of solidification. Despite the existence of a centrifugal force that could enhance the metal-mold contact, these values are lower than those generally reported for static molds with or without an insulating coating at the mold inner surface. The implemented model shows that the heat loss by radiation is dominant over that by convection at the tube inner surface, causing the formation of a solidification front that meets another front coming from the outer surface of the tube.

  4. Robust design optimization method for centrifugal impellers under surface roughness uncertainties due to blade fouling

    Science.gov (United States)

    Ju, Yaping; Zhang, Chuhua

    2016-03-01

    Blade fouling has been proved to be a great threat to compressor performance in operating stage. The current researches on fouling-induced performance degradations of centrifugal compressors are based mainly on simplified roughness models without taking into account the realistic factors such as spatial non-uniformity and randomness of the fouling-induced surface roughness. Moreover, little attention has been paid to the robust design optimization of centrifugal compressor impellers with considerations of blade fouling. In this paper, a multi-objective robust design optimization method is developed for centrifugal impellers under surface roughness uncertainties due to blade fouling. A three-dimensional surface roughness map is proposed to describe the nonuniformity and randomness of realistic fouling accumulations on blades. To lower computational cost in robust design optimization, the support vector regression (SVR) metamodel is combined with the Monte Carlo simulation (MCS) method to conduct the uncertainty analysis of fouled impeller performance. The analyzed results show that the critical fouled region associated with impeller performance degradations lies at the leading edge of blade tip. The SVR metamodel has been proved to be an efficient and accurate means in the detection of impeller performance variations caused by roughness uncertainties. After design optimization, the robust optimal design is found to be more efficient and less sensitive to fouling uncertainties while maintaining good impeller performance in the clean condition. This research proposes a systematic design optimization method for centrifugal compressors with considerations of blade fouling, providing a practical guidance to the design of advanced centrifugal compressors.

  5. Centrifugal step emulsification applied for absolute quantification of nucleic acids by digital droplet RPA.

    Science.gov (United States)

    Schuler, Friedrich; Schwemmer, Frank; Trotter, Martin; Wadle, Simon; Zengerle, Roland; von Stetten, Felix; Paust, Nils

    2015-07-07

    Aqueous microdroplets provide miniaturized reaction compartments for numerous chemical, biochemical or pharmaceutical applications. We introduce centrifugal step emulsification for the fast and easy production of monodisperse droplets. Homogenous droplets with pre-selectable diameters in a range from 120 μm to 170 μm were generated with coefficients of variation of 2-4% and zero run-in time or dead volume. The droplet diameter depends on the nozzle geometry (depth, width, and step size) and interfacial tensions only. Droplet size is demonstrated to be independent of the dispersed phase flow rate between 0.01 and 1 μl s(-1), proving the robustness of the centrifugal approach. Centrifugal step emulsification can easily be combined with existing centrifugal microfluidic unit operations, is compatible to scalable manufacturing technologies such as thermoforming or injection moulding and enables fast emulsification (>500 droplets per second and nozzle) with minimal handling effort (2-3 pipetting steps). The centrifugal microfluidic droplet generation was used to perform the first digital droplet recombinase polymerase amplification (ddRPA). It was used for absolute quantification of Listeria monocytogenes DNA concentration standards with a total analysis time below 30 min. Compared to digital droplet polymerase chain reaction (ddPCR), with processing times of about 2 hours, the overall processing time of digital analysis was reduced by more than a factor of 4.

  6. Clinical use of centrifugal pumps and the roller pump in open heart surgery: a comparative evaluation.

    Science.gov (United States)

    Yoshikai, M; Hamada, M; Takarabe, K; Okazaki, Y; Ito, T

    1996-06-01

    Centrifugal pumps have been used widely as the main pump in open heart surgery to reduce damage to blood elements and to reduce the activation of the coagulation system. The purpose of this study was the evaluation and comparison of the effects of two types of centrifugal pumps and of one type of roller pump on blood elements, the coagulation system, complements, and immunoglobulins. Two types of centrifugal pumps (Lifestream; St. Jude Medical, Chelmsford, Massachusetts; and BP-80: Medtronic, BioMedicus, Inc., Eden Prairie, Minnesota, U.S.A.) and one roller pump (Mera Co.) were used separately as the main pump for cardiopulmonary bypass (CPB) in 29 patients. Platelet counts, lactate dehydrogenase, antithrombin III, thrombin-antithrombin complex (TAT), complements (C3, C4, and CH50) and immunoglobulins G, A, and M values were measured before and after CPB and compared. Values, except those for TAT, showed no significant difference among the three groups. The TAT values increased less in each of the centrifugal pump groups than in the roller pump group. This finding suggests that thrombin synthesis might be suppressed by the use of a centrifugal pump.

  7. Experimental Study on Series Operation of Sliding Vane Pump and Centrifugal Pump

    Directory of Open Access Journals (Sweden)

    Tao Li

    2013-01-01

    Full Text Available A platform for sliding vane pump and centrifugal pump tests is installed to study the series operation of them under different characteristics of pipeline. Firstly, the sliding vane pump and the centrifugal pump work independently, and the performance is recorded. Then, the two types of pumps are combined together, with the sliding vane pump acting as the feeding pump. Comparison is made between the performance of the independently working pump and the performance of series operation pump. Results show that the system flow rate is determined by the sliding vane pump. In order to ensure the stability of the series operation pumping system, the energy consumption required by the pipeline under the system flow should be greater than the pressure energy centrifugal pump can generate. Otherwise, the centrifugal pump can not operate stably, with reflux, swirl, gas-liquid two-phase flow in the runner and strong vibration and noise. The sliding vane pump can be in serial operation with the centrifugal pump under limited conditions.

  8. Plasma physics

    CERN Document Server

    Drummond, James E

    2013-01-01

    A historic snapshot of the field of plasma physics, this fifty-year-old volume offers an edited collection of papers by pioneering experts in the field. In addition to assisting students in their understanding of the foundations of classical plasma physics, it provides a source of historic context for modern physicists. Highly successful upon its initial publication, this book was the standard text on plasma physics throughout the 1960s and 70s.Hailed by Science magazine as a ""well executed venture,"" the three-part treatment ranges from basic plasma theory to magnetohydrodynamics and microwa

  9. DE-1 observations of polar O(+) stream bulk parameters and comparison with a model of the centrifugally-accelerated polar wind

    Science.gov (United States)

    Ho, C. Wing; Horwitz, J. L.

    A survey of bulk parameters of analyzable O(+) outward streams in the mid-altitude (3-4.7 R(sub E) geocentric distance) polar cap magnetosphere is obtained from measurements by the Retarding Ion Mass Spectrometer (RIMS) aboard the Dynamics Explorer-1 (DE-1) spacecraft. There is wide scatter in the obtained densities, but they do display discernible trends: the average O(+) density in these streams decreases from about 60 ions/cc at 3.5 R(sub E) to about 1 ion/cc at 4.6 R(sub E). The streaming velocities are somewhat more defined, and their average increases from about 8 km/s at 3.5 R(sub E) to about 12 km/s at 4.6 R(sub E). The densities and bulk velocities are inversely correlated. We have further compared these observational trends with model profiles for the centrifugally-accelerated polar wind as recently described by Horwitz et al. (1994). The large outflow velocities observed can be understood in part as centrifugally-driven by convection with ionospheric electric field magnitudes of the order 50-70 mV/m, perhaps including plasma expansion effects.

  10. Effect of a bearing gap on hemolytic property in a hydrodynamically levitated centrifugal blood pump with a semi-open impeller.

    Science.gov (United States)

    Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu; Yambe, Tomoyuki; Imachi, Kou; Yamane, Takashi

    2013-01-01

    We have developed a hydrodynamically levitated centrifugal blood pump with a semi-open impeller for long-term circulatory assist. The pump uses hydrodynamic bearings to enhance durability and reliability without additional displacement-sensors or control circuits. However, a narrow bearing gap of the pump has a potential for hemolysis. The purpose of this study is to develop the hydrodynamically levitated centrifugal blood pump with a semi-open impeller, and to evaluate the effect of a bearing gap on hemolytic property. The impeller levitates using a spiral-groove type thrust bearing, and a herringbone-groove type radial bearing. The pump design was improved by adopting a step type thrust bearing and optimizing the pull-up magnetic force. The pump performance was evaluated by a levitation performance test, a hemolysis test and an animal experiment. In these tests, the bearing gap increased from 1 to 63 μm. In addition, the normalized index of hemolysis (NIH) improved from 0.415 to 0.005 g/100 l, corresponding to the expansion of the bearing gap. In the animal experiment for 24 h, the plasma-free hemoglobin remained within normal ranges (pump was improved to the acceptable level by expanding the bearing gap greater than 60 μm.

  11. Density-Gradient Mediated Band Extraction of Leukocytes from Whole Blood Using Centrifugo-Pneumatic Siphon Valving on Centrifugal Microfluidic Discs.

    Directory of Open Access Journals (Sweden)

    David J Kinahan

    Full Text Available Here we present retrieval of Peripheral Blood Mononuclear Cells by density-gradient medium based centrifugation for subsequent analysis of the leukocytes on an integrated microfluidic "Lab-on-a-Disc" cartridge. Isolation of white blood cells constitutes a critical sample preparation step for many bioassays. Centrifugo-pneumatic siphon valves are particularly suited for blood processing as they function without need of surface treatment and are 'low-pass', i.e., holding at high centrifugation speeds and opening upon reduction of the spin rate. Both 'hydrostatically' and 'hydrodynamically' triggered centrifugo-pneumatic siphon valving schemes are presented. Firstly, the geometry of the pneumatic chamber of hydrostatically primed centrifugo-pneumatic siphon valves is optimised to enable smooth and uniform layering of blood on top of the density-gradient medium; this feature proves to be key for efficient Peripheral Blood Mononuclear Cell extraction. A theoretical analysis of hydrostatically primed valves is also presented which determines the optimum priming pressure for the individual valves. Next, 'dual siphon' configurations for both hydrostatically and hydrodynamically primed centrifugo-pneumatic siphon valves are introduced; here plasma and Peripheral Blood Mononuclear Cells are extracted through a distinct siphon valve. This work represents a first step towards enabling on disc multi-parameter analysis. Finally, the efficiency of Peripheral Blood Mononuclear Cells extraction in these structures is characterised using a simplified design. A microfluidic mechanism, which we termed phase switching, is identified which affects the efficiency of Peripheral Blood Mononuclear Cell extraction.

  12. LacaScore: a novel plasma sample quality control tool based on ascorbic acid and lactic acid levels.

    Science.gov (United States)

    Trezzi, Jean-Pierre; Bulla, Alexandre; Bellora, Camille; Rose, Michael; Lescuyer, Pierre; Kiehntopf, Michael; Hiller, Karsten; Betsou, Fay

    Metabolome analysis is complicated by the continuous dynamic changes of metabolites in vivo and ex vivo. One of the main challenges in metabolomics is the robustness and reproducibility of results, partially driven by pre-analytical variations. The objective of this study was to analyse the impact of pre-centrifugation time and temperature, and to determine a quality control marker in plasma samples. Plasma metabolites were measured by gas chromatography-mass spectrometry (GC-MS) and analysed with the MetaboliteDetector software. The metabolites, which were the most labile to pre-analytical variations, were further measured by enzymatic assays. A score was calculated for their use as quality control markers. The pre-centrifugation temperature was shown to be critical in the stability of plasma samples and had a significant impact on metabolite concentration profiles. In contrast, pre-centrifugation delay had only a minor impact. Based on the results of this study, whole blood should be kept on wet ice and centrifuged within maximum 3 h as a prerequisite for preparing EDTA plasma samples fit for the purpose of metabolome analysis. We have established a novel blood sample quality control marker, the LacaScore, based on the ascorbic acid to lactic acid ratio in plasma, which can be used as an indicator of the blood pre-centrifugation conditions, and hence the suitability of the sample for metabolome analyses. This method can be applied in research institutes and biobanks, enabling assessment of the quality of their plasma sample collections.

  13. Air Pressure-Assisted Centrifugal Dewatering of Concentrated Fine Sulfide Particles

    Directory of Open Access Journals (Sweden)

    R. Asmatulu

    2011-01-01

    Full Text Available An air pressure-assisted centrifugal dewatering method was developed and used for the dewatering of concentrated finesulfide particles, such as sphalerite, galena, and chalcopyrite. This filtration method was mainly designed to increase the filtration rate during the drainage cycle and, hence, produce drier filter cakes, which in turn could reduce the cost and emission problems/concerns of thermal dryers in the preparation plants. Several dewatering parameters, including applied pressure, centrifugal force (G-force, spin time, cake thickness, and surface hydrophobization, were tested to optimize the processing conditions. Test results showed that, at higher air pressure and centrifugal force, the cake moisture reduction was more than 70%, depending on the testing conditions. As a result, it can be-concluded that the novel filtration method effectively works on the dewatering of fine particles (–150 μm.

  14. Performance analysis on solid-liquid mixed flow in a centrifugal pump

    Science.gov (United States)

    Ning, C.; Wang, Y.

    2016-05-01

    In order to study the solid-liquid mixed flow hydraulic characteristics of centrifugal pump, the Pro/E software was used for three-dimensional modeling of centrifugal pump chamber. By using the computational fluid dynamics software CFX, the numerical simulation calculation of solid-liquid two-phase flow within whole flow passage of centrifugal pump was conducted. Aim at different particle diameters, the Reynolds-averaged N-S equations with the RNG k-Ɛ turbulence model and SIMPLEC algorithm were used to simulate the two-phase flow respectively on the condition of different volume fraction. The influence of internal flow characteristic on pump performance was analyzed. On the conditions of different particle diameter and different volume fraction, the turbulence kinetic energy and particle concentration are analyzed. It can be found that the erosion velocity ratio on the flow channel wall increases along with the increasing of the volume fraction

  15. Parametric Study and Design Optimization of Centrifugal Pump Impeller-A Review

    Directory of Open Access Journals (Sweden)

    Vijaypratap R Singh ,

    2014-01-01

    Full Text Available Centrifugal pumps are widely used for irrigation, water supply plants, steam power plants, sewage, oil refineries, chemical plants, hydraulic power service, food processing factories and mines, because of their suitability in practically any service. Therefore it is necessary to find out the design parameters and working conditions that yield optimal output and maximum efficiency with lowest power consumption. Study indicates that Computational fluid dynamics (CFD analysis is being increasingly applied in the design of centrifugal pumps. With the aid of the CFD approach, the complex internal flows in water pump impellers, can be well predicted, to speed up the pump design procedure. This paper exposes the various research work carried out in this direction especially in the content of parametric study and optimization of centrifugal pump impeller using CFD tool and DoE technique. Literature surveys indicate that very restricted work has been done in this area.

  16. HYDRODYNAMIC OPTIMIZATION DESIGN OF LOW SOLIDITY VANED DIFFUSER FOR A CENTRIFUGAL PUMP USING GENETIC ALGORITHMS

    Institute of Scientific and Technical Information of China (English)

    LI Jun; FENG Zhen-ping; TSUKAMOTO Hiroshi

    2004-01-01

    This paper presents a hydrodynamic redesign of the conventional vaned diffuser into the low solidity vaned diffuser for the maximum static pressure recovery in a centrifugal pump. A Bezier curve representation for profile description was coupled with a blade-to-blade flow calculation and a real-coded genetic algorithm. A low solidity vaned diffuser of 0.89 in solidity was obtained through the present optimum design. Numerical analysis and experimental test were made to evaluate the hydrodynamic performance of the centrifugal pump with the designed low solidity vaned diffuser and original vaned diffuser. The obtained results demonstrate that the centrifugal pump with the optimized vaned diffuser has compact size compared with the original one while the performance requirements have been met.

  17. Numerical Simulation of Solidification of Work Roll in Centrifugal Casting Process

    Institute of Scientific and Technical Information of China (English)

    Nannan Song; Yikun Luan; Yunlong Bai; Z.A. Xu; Xiuhong Kang; Dianzhong Li

    2012-01-01

    A program on the solidification process of horizontal centrifugal casting coupled with eutectic carbides segregation has been developed in this paper. Due to the geometrical features of work roll, a cylindrical coordinate system was used. The temperature field of the outer layer at the end of filling process was imported as the initial temperature condition for the solidification process. The model of eutectic carbides segregation caused by different densities between eutectic MC and the molten steel was coupled in the program. The temperature field of the outer layer of work roll during horizontal centrifugal casting process was investigated. Results show that the outer layer has a "sandwich shape" solid fraction manner. Results also indicate that the segregation of eutectic MC is quite severe during centrifugal casting process. It forms four zones of different content of carbides in radial direction. The simulated results of MC carbides segregation phenomenon agree with the experimental observations.

  18. Solidified structure of thin-walled titanium parts by vertical centrifugal casting

    Directory of Open Access Journals (Sweden)

    Wu Shiping

    2011-05-01

    Full Text Available The solidified structure of the thin-walled and complicated Ti-6Al-4V castings produced by the vertical centrifugal casting process was studied in the present work. The results show that the wall thickness of the section is featured with homogeneously distributed fine equiaxial grains, compared with the microstructure of the thick-walled section. The grain size of the castings has a tendency to decrease gradually with the increasing of the centrifugal radius. The inter-lamellar space in thick-walled casting parts is bigger than that of the thin-walled parts, and the profile of inter-lamellar space is not susceptible to the centrifugal radius.

  19. Single-step fabrication of quantum funnels via centrifugal colloidal casting of nanoparticle films

    Science.gov (United States)

    Kim, Jin Young; Adinolfi, Valerio; Sutherland, Brandon R.; Voznyy, Oleksandr; Kwon, S. Joon; Kim, Tae Wu; Kim, Jeongho; Ihee, Hyotcherl; Kemp, Kyle; Adachi, Michael; Yuan, Mingjian; Kramer, Illan; Zhitomirsky, David; Hoogland, Sjoerd; Sargent, Edward H.

    2015-07-01

    Centrifugal casting of composites and ceramics has been widely employed to improve the mechanical and thermal properties of functional materials. This powerful method has yet to be deployed in the context of nanoparticles--yet size-effect tuning of quantum dots is among their most distinctive and application-relevant features. Here we report the first gradient nanoparticle films to be constructed in a single step. By creating a stable colloid of nanoparticles that are capped with electronic-conduction-compatible ligands we were able to leverage centrifugal casting for thin-films devices. This new method, termed centrifugal colloidal casting, is demonstrated to form films in a bandgap-ordered manner with efficient carrier funnelling towards the lowest energy layer. We constructed the first quantum-gradient photodiode to be formed in a single deposition step and, as a result of the gradient-enhanced electric field, experimentally measured the highest normalized detectivity of any colloidal quantum dot photodetector.

  20. A comparative evaluation of fluidized bed assisted drag finishing and centrifugal disk dry finishing

    Directory of Open Access Journals (Sweden)

    M. Barletta

    2014-06-01

    Full Text Available Drag finishing of brass (Cu-30 wt.% Zn rings using fluidized abrasives, which is a new finishing technology, is comparatively evaluated with centrifugal disk finishing. The comparison was performed by selecting the same abrasive granulates of two different sizes and operating the equipment for the same processing time or at their respective maximum speeds. The experimental analysis investigated the change in workpiece morphology, material removal during finishing and dimensional accuracy. The results showed that each of the types of equipment investigated in the study were capable of a high finishing performance with a relatively short processing time. However, fluidized bed assisted drag finishing was more effective than centrifugal disk finishing in both the achievable quality of the processed parts and reduced processing time. In contrast, centrifugal disk finishing was preferable whenever low erosion and stringent dimensional tolerances were demanded.

  1. A New Optimization Method for Centrifugal Compressors Based on 1D Calculations and Analyses

    Directory of Open Access Journals (Sweden)

    Pei-Yuan Li

    2015-05-01

    Full Text Available This paper presents an optimization design method for centrifugal compressors based on one-dimensional calculations and analyses. It consists of two parts: (1 centrifugal compressor geometry optimization based on one-dimensional calculations and (2 matching optimization of the vaned diffuser with an impeller based on the required throat area. A low pressure stage centrifugal compressor in a MW level gas turbine is optimized by this method. One-dimensional calculation results show that D3/D2 is too large in the original design, resulting in the low efficiency of the entire stage. Based on the one-dimensional optimization results, the geometry of the diffuser has been redesigned. The outlet diameter of the vaneless diffuser has been reduced, and the original single stage diffuser has been replaced by a tandem vaned diffuser. After optimization, the entire stage pressure ratio is increased by approximately 4%, and the efficiency is increased by approximately 2%.

  2. An Experimental Investigation on the Drying of Sliced Food Products in Centrifugal Fluidized Bed

    Institute of Scientific and Technical Information of China (English)

    M.H.Shi; Y.L.Hao; 等

    1998-01-01

    An experimental investigation on the fluidization and drying characteristics of sliced food products in a centrifugal fluidized bed dryer was carried out,The rotaing speed ranges from 300 rpm to 500 rpm.Sliced potato and radish were used as the testing materials.The results show that the sliced materials can be fluidized well in the centrifugal fluidized bed.The fluidized curve has a maximum value and the critical fluidized velocities vary with the type of the test material,its shape and dimension as well as operating parameters.The sliced food materials can be dried very well and fast in the centrifugal fluidized bed with a large productivity.The factors that influence the drying process were examined and discussed.The final shape and inner structure of the dried products were observed.The water recovery characteristics of the drried products were also investigated.

  3. Comparison of gradual and rapid onset runs in a short-arm centrifugation

    Science.gov (United States)

    Miyamoto, A.; Saga, K.; Kinoue, T.; Nakazato, T.; Hirayanagi, K.; Yajima, K.; Hayashi, S.; Matsumoto, S.

    A gradual onset run (GOR) in a short-arm centrifugation was performed on ten healthy students. The centrifuge had a 1.8 m radius, and the subjects sat on a chair in a cabin. The Gz force increased to 2.2 Gz at 0.1 °/sec 2 for 32 min. and the same Gz-level was maintained for 20 min. Three out of ten subjects completed the whole protocol; the load on the others was terminated because of symptoms or increased heart rate. There were few symptoms such as vertigo, that was a common problem with a rapid onset run (ROR) in former experiments, due to the short-arm centrifugation. The changes of the flicker test after the load were much less in the GOR protocol than in the ROR protocol, even in the terminated group. GOR seemed preferable to ROR in preventing vertigo even though it took longer to reach the necessary G load.

  4. The margin of safety in the use of a straight path centrifugal blood pump.

    Science.gov (United States)

    Kijima, T; Nojiri, C; Oshiyama, H; Horiuchi, K; Nogawa, A; Hamasaki, H; Ogihara, M; Katsuda, H S; Amano, N; Fukasawa, H

    1994-09-01

    A new centrifugal blood pump with a rotor that arranges 6 straight paths radially was developed for open heart surgery and temporary circulatory support. We describe comparative studies of the margin of safety in the practical use of the new pump. This pump was evaluated for temperature increase, cavitation, and pressure sensitivity. Two commercially available centrifugal pumps, the Biomedicus cone type and the Sarns 3M impeller type, were used as control pumps. The temperature increase in the new pump was four times slower than in the impeller pump when the outlet and the inlet of the pump was clamped. No sign of cavitation was observed when 0.1 ml air was introduced to the pump inlet under a negative pressure of 200 mm Hg in fresh bovine blood. As for pressure sensitivity of centrifugal pumps in practical applications, circuit resistance was a more essential factor than flow-pressure curves of the pump.

  5. Enhanced versatility of fluid control in centrifugal microfluidic platforms using two degrees of freedom.

    Science.gov (United States)

    Cao, Xiaobao; deMello, A J; Elvira, K S

    2016-04-01

    Centrifugal microfluidic platforms have significant potential in commercial applications because of their operational flexibility and minimal external infrastructure requirements. However, the dynamic and real-time control of fluid flow within traditional centrifugal microfluidic platforms is problematic. To address this significant limitation, we propose a two degrees of freedom platform, in which a digital servo is located at each end of an arm driven by a motor. This allows for reversible inward pumping between multiple chambers with perfect efficiency. Furthermore, the addition of a second degree of freedom allows position-based pressure controlled burst valves to be accessed and operated in an independent fashion. To demonstrate the efficacy of this technical innovation, we show rapid and configurable flow switching between three target chambers within a centrifugal microfluidic device.

  6. On the saturation of the centrifugally excited curvature drift instability in AGN magnetospheres

    CERN Document Server

    Osmanov, Z

    2009-01-01

    We study a saturation process of the centrifugally driven curvature drift instability (CDI) in AGN magnetospheres close to the light cylinder surface to examine the twisting of magnetic field lines leading to the free motion of AGN winds, that completely kills the instability. Considering the Euler, continuity, and induction equations, by taking into account the resonant conditions, we derive the growth rate of the CDI. We show that due to the centrifugal effects, the rotational energy is efficiently pumped directly into the drift modes, that leads to the generation of a toroidal component of the magnetic field. As a result, the magnetic field lines transform into such a configuration when particles do not experience any forces and since the instability is centrifugally driven, at this stage the CDI is completely killed.

  7. Influence of Prewhirl Regulation by Inlet Guide Vanes on Cavitation Performance of a Centrifugal Pump

    Directory of Open Access Journals (Sweden)

    Lei Tan

    2014-02-01

    Full Text Available The influence of prewhirl regulation by inlet guide vanes (IGVs on a centrifugal pump performance is investigated experimentally and numerically. The experimental results show that IGVs can obviously change the head and increase the efficiency of the tested centrifugal pump over a wide range of flow rates. Although the cavitation performance is degraded, the variation of the cavitation critical point is less than 0.5 m. Movement of the computed three-dimensional streamlines in suction pipe and impeller are analyzed in order to reveal the mechanism how the IGVs realize the prewhirl regulation. The calculated results show that the influence of IGVs on the cavitation performance of centrifugal pump is limited by a maximum total pressure drop of 1777 Pa, about 7.6% of the total pressure at the suction pipe inlet for a prewhirl angle of 24°.

  8. Optimization and analysis of centrifugal pump considering fluid-structure interaction.

    Science.gov (United States)

    Zhang, Yu; Hu, Sanbao; Zhang, Yunqing; Chen, Liping

    2014-01-01

    This paper presents the optimization of vibrations of centrifugal pump considering fluid-structure interaction (FSI). A set of centrifugal pumps with various blade shapes were studied using FSI method, in order to investigate the transient vibration performance. The Kriging model, based on the results of the FSI simulations, was established to approximate the relationship between the geometrical parameters of pump impeller and the root mean square (RMS) values of the displacement response at the pump bearing block. Hence, multi-island genetic algorithm (MIGA) has been implemented to minimize the RMS value of the impeller displacement. A prototype of centrifugal pump has been manufactured and an experimental validation of the optimization results has been carried out. The comparison among results of Kriging surrogate model, FSI simulation, and experimental test showed a good consistency of the three approaches. Finally, the transient mechanical behavior of pump impeller has been investigated using FSI method based on the optimized geometry parameters of pump impeller.

  9. Dissolved air flotation and centrifugation as methods for oil recovery from ruptured microalgal cells.

    Science.gov (United States)

    Ghasemi Naghdi, Forough; Schenk, Peer M

    2016-10-01

    Solvent-free microalgal lipid recovery is highly desirable for safer, more sustainable and more economical microalgal oil production. Dispersed air flotation and centrifugation were evaluated for the ability to separate oil and debris from a slurry mixture of osmotically fractured Chaetoceros muelleri cells with and without utilizing collectors. Microalgal oil partially phase-separated as a top layer and partially formed an oil-in-water emulsion. Although collectors, such as sodium dodecyl sulphate enhanced selective flotation, by just adjusting the pH and cell concentration of the mixture, up to 78% of the lipids were recovered in the froth. Using centrifugation of fractured microalgal slurry resulted in removal of 60% cell debris and up to 68.5% of microalgal oil was present in the supernatant. Both methods, centrifugation and flotation provided options for separation of microalgal oil from C. muelleri slurry with similar fatty acid recoveries of 57% and 60%, respectively. Copyright © 2016. Published by Elsevier Ltd.

  10. Direct calculation of acceleration field through homogeneous transformation for two-axis centrifuge

    Institute of Scientific and Technical Information of China (English)

    吴广玉; 任顺清; 陈希军

    2003-01-01

    A precision centrifuge is an inertial navigation test equipment used for calibrating the characteristicsof accelerometers with high overloading, and a two-axis centrifuge can be used to generate either constant accel-eration or harmonic acceleration. The moving trajectory equation about the origin of the accelerometer coordinatesystem in a two-axis centrifuge was directly deduced through homogeneous transformation. The acceleration vec-tor of the origin in accelerometer coordinate system was achieved by making the second derivative of this trajec-tory equation. The acceleration components were acquired by decomposing this acceleration vector along thethree axes of the accelerometer coordinate system. The correctness of the homogeneous transformation was veri-fied through vector analysis.

  11. Solidification and remelting of Al through Al2O3 fibrous preform under centrifugal force

    Institute of Scientific and Technical Information of China (English)

    HU Guo-xin; LIU Jian-ju; ZHANG Li-xiang; TIAN Qin-wei

    2006-01-01

    The solidification and remelting of molten aluminum through a porous preform under centrifugal force field were modeled numerically. The results show that the transient solidification and remelting phenomena appear on the infiltration front and can be divided into two distinct regions: the remelting region and solid-liquid congruent melting region. The decrease of porosity always results in the increase of moving velocity difference between the infiltration front and the remelting front, which leads to the increase of the solid-liquid congruent region extent. But for the decrease of the rotational frequency, the difference of moving velocity between infiltration front and remelting front decreases, which leads to the decrease of regional extent. The infiltration front moving velocity is mainly influenced by the centrifugal infiltration pressure, whereas the remelting front moving velocity is mainly influenced by the material thermodynamics. The transient solidification and remelting phenomena are the intercoupling results between the centrifugal infiltration dynamics and the material thermodynamics.

  12. Single-step fabrication of quantum funnels via centrifugal colloidal casting of nanoparticle films.

    KAUST Repository

    Kim, Jin Young

    2015-07-13

    Centrifugal casting of composites and ceramics has been widely employed to improve the mechanical and thermal properties of functional materials. This powerful method has yet to be deployed in the context of nanoparticles--yet size-effect tuning of quantum dots is among their most distinctive and application-relevant features. Here we report the first gradient nanoparticle films to be constructed in a single step. By creating a stable colloid of nanoparticles that are capped with electronic-conduction-compatible ligands we were able to leverage centrifugal casting for thin-films devices. This new method, termed centrifugal colloidal casting, is demonstrated to form films in a bandgap-ordered manner with efficient carrier funnelling towards the lowest energy layer. We constructed the first quantum-gradient photodiode to be formed in a single deposition step and, as a result of the gradient-enhanced electric field, experimentally measured the highest normalized detectivity of any colloidal quantum dot photodetector.

  13. Damages on pumps and systems the handbook for the operation of centrifugal pumps

    CERN Document Server

    Merkle, Thomas

    2014-01-01

    Damage on Pumps and Systems. The Handbook for the Operation of Centrifugal Pumps offers a combination of the theoretical basics and practical experience for the operation of circulation pumps in the engineering industry. Centrifugal pumps and systems are extremely vulnerable to damage from a variety of causes, but the resulting breakdown can be prevented by ensuring that these pumps and systems are operated properly. This book provides a total overview of operating centrifugal pumps, including condition monitoring, preventive maintenance, life cycle costs, energy savings and economic aspects. Extra emphasis is given to the potential damage to these pumps and systems, and what can be done to prevent breakdown. Addresses specific issues about pumping of metal chips, sand, abrasive dust and other solids in fluidsEmphasis on economic and efficiency aspects of predictive maintenance and condition monitoring Uses life cycle costs (LCC) to evaluate and calculate the costs of pumping systems

  14. Evaluation of conventional castaneda and lysis centrifugation blood culture techniques for diagnosis of human brucellosis.

    Science.gov (United States)

    Mantur, Basappa G; Mangalgi, Smita S

    2004-09-01

    We investigated the role of the lysis centrifugation blood culture technique over the conventional Castaneda technique for the diagnosis of human brucellosis. The lysis centrifugation technique has been found to be more sensitive in both acute (20% higher sensitivity; P < 0.00001) and chronic (40% higher sensitivity; P = 0.087) forms of brucellosis. The major advantage of lysis centrifugation was in the mean detection time, which was only 2.4 days in acute and 2.7 days in chronic cases, with 103 out of 110 (93.6%) and 17 out of 20 (85%) cultures from acute and chronic brucellosis, respectively, detected before the conventional culture was positive. Our results confirmed the potential usefulness of the lysis technique in diagnosis and institution of appropriate antibiotic therapy.

  15. Short communication. Stallion sperm quality after combined ejaculate fractionation and colloidal centrifugation

    Directory of Open Access Journals (Sweden)

    Francisco Crespo

    2015-12-01

    Full Text Available This study investigated the possible additive benefit of ejaculate fractionation and colloidal centrifugation on stallion sperm quality. Using an open-end artificial vagina, the sperm-rich fraction (FRAC-1 was separated from the rest of the ejaculate (FRAC-2 and a third sperm sample representing the combined ejaculate was reconstituted post-ejaculation (RAW. Each semen sample was processed for colloidal centrifugation. The percentage of abnormal spermatozoa was 17.8 ± 7.0% in RAW and 14.6 ± 9.5% in FRAC-1 but decreased to 11.4 ± 4.7% and 9.6 ± 6.9% respectively, after colloidal centrifugation. A sperm DNA fragmentation index of 10.9 ± 5.1% was observed in RAW and 7.5 ± 2.4% in FRAC-1 semen collected with the AV but this decreased to 7.8 ± 2.8% and 5.2 ± 2.3% after colloidal centrifugation. The rate of increase in sperm DNA fragmentation during the first 6 h of incubation at 37 ºC was 1.8 ± 0.9% per hour in RAW semen and 2.0 ± 2.0% per hour in FRAC-1 but this significantly decreased to 1.3 ± 1.4% and 0.9 ± 0.8% respectively after colloidal centrifugation. While stallion seminal characteristics can be improved using colloidal centrifugation, further enhancement is possible if the ejaculate is initially fractionated.

  16. Reconstitution of Human Ion Channels into Solvent-free Lipid Bilayers Enhanced by Centrifugal Forces.

    Science.gov (United States)

    Hirano-Iwata, Ayumi; Ishinari, Yutaka; Yoshida, Miyu; Araki, Shun; Tadaki, Daisuke; Miyata, Ryusuke; Ishibashi, Kenichi; Yamamoto, Hideaki; Kimura, Yasuo; Niwano, Michio

    2016-05-24

    Artificially formed bilayer lipid membranes (BLMs) provide well-defined systems for functional analyses of various membrane proteins, including ion channels. However, difficulties associated with the integration of membrane proteins into BLMs limit the experimental efficiency and usefulness of such BLM reconstitution systems. Here, we report on the use of centrifugation to more efficiently reconstitute human ion channels in solvent-free BLMs. The method improves the probability of membrane fusion. Membrane vesicles containing the human ether-a-go-go-related gene (hERG) channel, the human cardiac sodium channel (Nav1.5), and the human GABAA receptor (GABAAR) channel were formed, and the functional reconstitution of the channels into BLMs via vesicle fusion was investigated. Ion channel currents were recorded in 67% of the BLMs that were centrifuged with membrane vesicles under appropriate centrifugal conditions (14-55 × g). The characteristic channel properties were retained for hERG, Nav1.5, and GABAAR channels after centrifugal incorporation into the BLMs. A comparison of the centrifugal force with reported values for the fusion force revealed that a centrifugal enhancement in vesicle fusion was attained, not by accelerating the fusion process but by accelerating the delivery of membrane vesicles to the surface of the BLMs, which led to an increase in the number of membrane vesicles that were available for fusion. Our method for enhancing the probability of vesicle fusion promises to dramatically increase the experimental efficiency of BLM reconstitution systems, leading to the realization of a BLM-based, high-throughput platform for functional assays of various membrane proteins.

  17. Platelet-rich plasma preparation using three devices : Implications for platelet activation and platelet growth factor release

    NARCIS (Netherlands)

    Everts, Peter A. M.; Mahoney, Christine Brown; Hoffmann, Johannes J. M. L.; Schonberger, Jacques P. A. M.; Box, Henk A. M.; Van Zundert, Andre; Knape, Johannes T. A.

    2006-01-01

    Background: In this study, three commercial systems for the preparation of platelet-rich plasma (PRP) were compared and platelet growth factors release was measured. Methods: Ten healthy volunteers donated whole blood that was fractionated by a blood cell separator, and a table-top centrifuge to pre

  18. Cavitation performance and flow characteristic in a centrifugal pump with inlet guide vanes

    Science.gov (United States)

    Tan, L.; Zha, L.; Cao, S. L.; Wang, Y. C.; Gui, S. B.

    2015-01-01

    The influence of prewhirl regulation by inlet guide vanes (IGVs) on cavitation performance and flow characteristic in a centrifugal pump is investigated. At the impeller inlet, the streamlines are regulated by the IGVs, and the axial velocity distribution is also influenced by the IGVs. Due to the total pressure loss on the IGVs, the cavitation performance of the centrifugal pump degrades. The cavitation area in impeller with IGVs is larger than one without IGVs. The specify values of total pressure loss between the suction pipe inlet and impeller inlet for three cavitation conditions show that the IGVs will generate additional pressure loss, which is related to the IGVs angles and cavitation conditions.

  19. A Turbidity Test Based Centrifugal Microfluidics Diagnostic System for Simultaneous Detection of HBV, HCV, and CMV

    Directory of Open Access Journals (Sweden)

    Hung-Cheng Chang

    2015-01-01

    Full Text Available This paper presents a LAMP- (loop-mediated isothermal amplification- based lab-on-disk optical system that allows the simultaneous detection of hepatitis B virus, hepatitis C virus, and cytomegalovirus. The various flow stages are controlled in the proposed system using different balance among centrifugal pumping, Coriolis pumping, and the capillary force. We have implemented a servo system for positioning and speed control for the heating and centrifugal pumping. We have also successfully employed a polymer light-emitting diode section for turbidity detection. The easy-to-use one-click system can perform diagnostics in less than 1 hour.

  20. MODEL OF CENTRIFUGAL EFFECT AND ATTITUDE MANEUVER STABILITY OF A COUPLED RIGID-FLEXIBLE SYSTEM

    Institute of Scientific and Technical Information of China (English)

    LI Zhi-bin; WANG Zhao-lin; WANG Tian-shu; LIU Ning

    2005-01-01

    The influences of nonlinear centrifugal force to large overall attitude motion of coupled rigid-flexible system was investigated. First the nonlinear model of the coupled rigidflexible system was deduced from the idea of "cenlrifugal potential field", and then the dynamic effects of the nonlinear centrifugal force to system attitude motion were analyzed by approximate calculation; At last, the Lyapunov function based on energy norm was selected,in the condition that only the measured values of attitude and attitude speed are available,and it is proved that the PD feedback control law can ensure the attitude stability during large angle maneuver.