WorldWideScience

Sample records for plants protecciones electricas

  1. Electric protections based in microprocessors in power plants; Protecciones electricas basadas en microprocesadores en centrales generadoras

    Energy Technology Data Exchange (ETDEWEB)

    Libreros, Domitilo; Castanon Jimenez, Jose Ismael [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    This article is centered around the substitution of the conventional electric protections of a power plant in connection type unit for protections based in microprocessors. A general model of conventional protection of a power plant is described and the number of analogic and digital signals that intervene in that model are quantified. A model is setup for power plant protection with microprocessors, analyzing each one of the modules that would form it. Finally, the algorithms to carry on such protection are presented. [Espanol] Este articulo se centra en torno a la sustitucion de las protecciones electricas convencionales de una central generadora en conexion tipo unidad por protecciones basadas en microprocesadores. Se describe el modelo general de proteccion convencional de una central generadora y se cuantifica el numero de senales analogicas y digitales que interviene en dicho modelo. Se propone un modelo para proteccion de centrales generadoras mediante microprocesadores, analizandose cada uno de los modulos que lo conformarian. Finalmente, se presentan los algoritmos para realizar dicha proteccion.

  2. Electric protections based in microprocessors in power plants; Protecciones electricas basadas en microprocesadores en centrales generadoras

    Energy Technology Data Exchange (ETDEWEB)

    Libreros, Domitilo; Castanon Jimenez, Jose Ismael [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    This article is centered around the substitution of the conventional electric protections of a power plant in connection type unit for protections based in microprocessors. A general model of conventional protection of a power plant is described and the number of analogic and digital signals that intervene in that model are quantified. A model is setup for power plant protection with microprocessors, analyzing each one of the modules that would form it. Finally, the algorithms to carry on such protection are presented. [Espanol] Este articulo se centra en torno a la sustitucion de las protecciones electricas convencionales de una central generadora en conexion tipo unidad por protecciones basadas en microprocesadores. Se describe el modelo general de proteccion convencional de una central generadora y se cuantifica el numero de senales analogicas y digitales que interviene en dicho modelo. Se propone un modelo para proteccion de centrales generadoras mediante microprocesadores, analizandose cada uno de los modulos que lo conformarian. Finalmente, se presentan los algoritmos para realizar dicha proteccion.

  3. Natural ionizing system to electrical protection and energy; Sistema ionizante natural de proteccion electrica y energias

    Energy Technology Data Exchange (ETDEWEB)

    Cabareda Fermin; Luis [Universidad de Los Andes (Venezuela)]. E-mail: lcabaredaf@gmail.com

    2013-03-15

    This is the new highest technology, 100% Venezuelan and unique in the world, technological innovation, world patent for maximum protection, security and zero risk (0) to all electrical and power generation systems: hydroelectric and thermoelectric power plants, wind, nuclear and solar power plants, etc; it's the only technology around the world that has the potential to disperse and propagate to land mass the enormous energies associated to the atmospheric discharges (lightning), which are in the order: 200,000 to 500,000 Amperes; 1,000 million Kilowatts and high-level transient voltage of 100 million Volts. This new high technology is the solution to the paradigm of Benjamin Franklin and it is the mechanism to end blackouts that produce so many damages and losses of billions of dollars to both generators and users of electrical service, throughout the world. [Spanish] Esta nueva mas alta tecnologia, 100% venezolana y unica en el mundo, innovacion tecnologica, patente mundial ofrece maxima proteccion, seguridad y riesgo cero (0) a todos los sistemas de generacion electrica: centrales hidroelectricas, termoelectricas, de viento, nucleares y solar, otros; es la unica tecnologia en el mundo que tiene el potencial para dispersar y propagar a la masa terrestre las enormes energias asociadas a las descargas atmosfericas (rayos) que estan en el orden de: 200.000 a 500.000 amperios, 1.000 millones de kilovatios y voltajes transitorios de alto nivel de 100 millones de voltios. Esta nueva alta tecnologia es la solucion al paradigma de Benjamin Franklin y es el mecanismo para eliminar apagones que producen danos y perdidas de billones de dolares para ambos: generados y usuarios del servicio electrico, alrededor del mundo.

  4. Educational software tool for protection system engineers: distance relay; Herramienta educativa para la formacion de ingenieros en protecciones electricas: relevador de distancia

    Energy Technology Data Exchange (ETDEWEB)

    Trujillo-Guajardo, L.A.; Conde-Enriquez, A. [Universidad Autonoma de Nuevo Leon, Nuevo Leon (Mexico)]. E-mail: luistrujillo84@gmail.com; con_de@yahoo.com

    2012-04-15

    In this article, a graphical software tool is presented; this tool is based on the education of protection system engineers. The theoretical fundaments used for the design of operation characteristics of distance relays and their algorithms are presented. The software allows the evaluation and analysis of real time events or simulated ones of every stage of design of the distance relay. Some example cases are presented to illustrate the activities that could be done with the graphical software tool developed. [Spanish] En este articulo se presenta una herramienta computacional grafica para apoyar la formacion de ingenieros en protecciones electricas. Los fundamentos teoricos para el diseno de caracteristicas de operacion de relevadores de distancia, asi como las rutinas de programacion de un relevador de distancia son presentados. La herramienta desarrollada permite la evaluacion de las etapas de diseno de relevadores y el analisis de la operacion ante eventos reales o simulados. Se presentan algunos casos de ejemplo para ilustrar las actividades didacticas que son posibles de realizar con la herramienta presentada.

  5. Protection of structures and buildings against the effect of electrical storms: basic concepts, evolution and application in Mexico; Proteccion contra el efecto de las tormentas electricas de estructuras y edificios: conceptos basicos, evolucion y aplicacion en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Galvan Diego, Arturo; Velazquez Sanchez, Raul [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    observacion cientifica, ha demostrado su eficacia en la modernizacion de cientos de procesos industriales, comerciales, de comunicacion y de servicios, asi como de los materiales y metodologias utilizadas para la proteccion de diversos equipos y procesos; desde la proteccion en sistema y equipos en alta tension hasta sistemas que manejan muy baja energia, entre los que incluyen electronicos y digitales. Sin embargo, existen leyes fundamentales como la ley de Ohm, la ley de gravedad o la ley universal de gases que, pese a que fueron descubiertos hace muchos anos, siguen vigentes y su validez proporciona elementos invaluables para el desarrollo de nuevos metodos, procesos y desarrollos tecnologicos. Uno de los casos mas relevantes que amalgama la aplicacion de criterios fundamentales y el desarrollo de nuevas tecnologias y su aplicacion en los llamados dispositivos de proteccion no convencionales lo constituye la proteccion contra el efecto de las tormentas electricas en edificios y estructuras. La aplicacion de estos dispositivos en el ambito mundial ha generado escepticismo de una gran parte de la comunidad cientifica, reacciones diversas entre los usuarios y un postura firme por parte de los fabricantes para que dichas tecnologias sean incluidas en normas internacionales. El objetivo de este articulo es ofrecer al lector la informacion basica sobre los inicios de la proteccion, la evolucion que los metodos de proteccion contra las tormentas electricas han tenido desde el siglo XVIII, la aplicacion de los criterios fundamentales de proteccion en estructuras o edificios modernos y su contenido, asi como la situacion que prevalece actualmente en los comites de las diversas organizaciones normativas nacionales e internacionales en lo referente a la inclusion de las nuevas tecnologias en las guias de diseno.

  6. Radiological protection in nuclear power plants; La proteccion radiologica en las centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Zorrilla R, S. [CFE. Central Laguna Verde, Km. 42.5 Carretera Cardel-Nautla, Veracruz (Mexico)

    2008-12-15

    This presentation sharing experiences which correspond to the nuclear power plant of Laguna Verde. This nuclear power plant is located at level 2 of four possible, in the classification performance of the World Association of Nuclear Operators (WANO), which means the mexican nuclear power plant is classified in terms of its performance indicators and above the average achieved by their counterparts americans and canadians. In the national context, the nuclear power plant of Laguna Verde has also been honored with several awards such as the National Quality Award, the Clean Industry Certificate, the distinction of Environmental Excellence and others of similar importance. For the standards of WANO, the basic idea is that there are shortcomings in one of nuclear power plant concern to all partners. The indicators used for the classification will always go beyond more compliance with regulations, which are assumed, and rather assume come or a path to excellence. Among the most important indicators are: the collective dose, the percentage of areas declared as contaminated, the number, type and tendency of contamination personal cases, the number of dosimetry alarms, the number of unplanned exposures, loss control of high radiation areas and the release of contaminated material outside the restricted areas. Furthermore, as already indicated, nuclear power plants are of special care situations, such as, carrying out work in areas with radiation fields of more than 15 mSv h{sup -1}, the movement of spent fuel in the reload floor. The consideration of the minimum total effective dose equivalent as a criterion for prescribing tools that reduce exposures, but may increase the external cases of contaminated casualties, the experience in portals such as workers subject to radiology, where exposure in industrial radiography, and so on. Special mention deserve the conditions generated during fuel reload stops, which causes a massive personnel movement, working simultaneously on

  7. Actions in the electrical sector to propitiate the environmental protection; Acciones en el sector electrico para propiciar la proteccion ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Trevino Gaspari, Mateo [Fideicomiso de Ahorro de Energia (FIDE) (Mexico)

    1997-07-01

    The saving of electrical energy is one of the most efficient means to propitiate the environmental protection in the surroundings of the facilities used in the production of electrical energy. The emission of polluting agents associated with the electric power generation is analyzed, among them, CO{sub 2}, SO{sub 2} and NO{sub 2}, along with the particulate emission of ash or soot. In addition, an analysis is made of the contribution of the electrical energy saving to the environmental protection and the actions that the Comision Federal de Electricidad of Mexico will undertake on the electric energy saving for the 1995 to the 2000 period. [Spanish] El ahorro de energia electrica es uno de los medios mas eficientes para propiciar la proteccion ambiental en el entorno de las instalaciones usadas en la produccion de energia electrica. Se analiza la emision de contaminantes asociados con la generacion electrica, entre ellos, el CO{sub 2}, el SO{sub 2} y NO{sub 2}, junto con la emision de particulas de ceniza o de hollin. Ademas se analiza la contribucion del ahorro de energia electrica a la proteccion ambiental y las acciones que emprendera la Comision Federal de Electricidad de Mexico sobre ahorro de energia electrica para el periodo 1995 al 2000.

  8. Control, protection and measuring switchboards; Tableros de control, proteccion y medicion

    Energy Technology Data Exchange (ETDEWEB)

    Marron Pena, Gustavo A. [Luz y Fuerza del Centro, Mexico, D. F. (Mexico)

    1997-12-31

    Basically a switchboard is a cabinet or panel that contains equipment for protection of measuring and control high tension electric power components of high tension, such as: transmission power lines, power station generators or power plants, power transformers, and distribution feeders. In this paper the importance of control, Protection and Measuring Switchboards is discussed and the power installations of the national electric system is analyzed and finally, a description is made of the quality system applied in the manufacture of switchboards at Luz y Fuerza del Centro in accordance with ISO-9000 and NMX-CC Standards [Espanol] Un tablero basicamente es un gabinete o panel que contiene equipos que sirven para proteger, medir y controlar componentes electricos de potencia en alta tension, como son: lineas de transmision, generadores de centrales o plantas electricas, transformadores de potencia y alimentadores de distribucion. En este documento se analiza la importancia de los tableros de control, la proteccion y medicion en las instalaciones de potencia del sistema electrico nacional y por ultimo se describe el sistema de calidad aplicado en la fabricacion de tableros de Luz y Fuerza del Centro de acuerdo con las normas ISO-9000 y NMX-CC

  9. The PBMR electric power generation plant; La planta de generacion de energia electrica PBMR

    Energy Technology Data Exchange (ETDEWEB)

    Perez S, G.; Santacruz I, I.; Martin del Campo M, C. [FI-UNAM, 04500 Mexico D.F. (Mexico)] e-mail: gabriela_perez@engineer.com

    2003-07-01

    This work has as purpose to diffuse in a general way the technology of the one modulate reactor of pebble bed. Because our country is in developing ways, the electric power demand goes in increase with that which it is presented the great challenge of satisfying this necessity, not only being in charge of the one fact per se, but also involving the environmental aspect and of security. Both factors are covered by the PBMR technology, which we approach in their basic aspects with the purpose that the public opinion knows it and was familiarized with this type of reactors that well could represent a solution for our growing electricity demand. We will treat this reactor visualizing it like part of a generation plant defining in first place to the itself reactor. We will see because that the system PBMR consists of 2 main sections: the reactor and the unit of energy conversion, highlighting that the principle of the PBMR reactor operation is based on the thermodynamic Brayton cycle cooled by helium and that, in turn, it transmits the energy in form of heat toward a gas turbine. In what concerns to the fuel, it peculiar design due to its spherical geometry is described, aspect that make to this reactor different from the traditional ones that use fuel rods. In fact in the fuel spheres of the PBMR it is where it resides great part of it inherent security since each particle of fuel, consistent in uranium dioxide, is lined one with coal and silicon carbide those which form an impenetrable barrier containing to the fuel and those radioactive products that result of the nuclear reactions. Such particles are encapsulated in graphite to form the sphere or 'pebble', of here born the name of this innovative technology. (Author)

  10. The Biogas from bio-energy electrical power plant of Nuevo Leon; Central electrica de biogas de bioenergia de Nuevo Leon

    Energy Technology Data Exchange (ETDEWEB)

    Arvizu F, Jose L [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Saldana M, Jaime L [Sistemas de Energia Internacional S.A. de C.V. (Mexico)

    2005-07-01

    The biogas from bio-energy electrical power plant of Nuevo Leon represents, in all the national territory, the first experience on the advantage of biogas emitted by the sanitary landfills for the generation of electrical energy. Therefore, one of the specific objectives of this paper is the one of diffusion and reproduction of the same one in other cities of Mexico and Latin America. The project is framed within the world-wide policies on the control of emissions for the reduction of the greenhouse effect gases (GEG) and its impact in the global climatic change. The gas emitted by the trash sanitary landfills, commonly known as biogas, is a gas mixture derived from the decomposition of the organic matter of the municipal trash by microorganisms in anaerobic conditions. Biogas generated in the sanitary landfills has a methane content of 55% and a 35% of carbon dioxide. The balance 10% is made up of water steam, hydrogen, nitrogen, oxygen, hydrogen sulfur and other gases in minimum amounts. [Spanish] La Central Electrica de Biogas de Bioenergia de Nuevo Leon representa, en todo el territorio nacional, la primera experiencia sobre el aprovechamiento del biogas emitido por los rellenos sanitarios para la generacion de energia electrica. Por esta razon, uno de los objetivos especificos de este trabajo es la de difusion y reproduccion del mismo en otras ciudades de Mexico y Latinoamerica. El proyecto esta enmarcado dentro de las politicas mundiales sobre el control de emisiones para la reduccion de los gases de efecto invernadero (GEI) y su impacto en el cambio climatico global. El gas emitido por la basura dispuesta en los rellenos sanitarios, comunmente conocido como biogas, es una mezcla de gases derivado de la descompensacion de la materia organica de la basura municipal por microorganismos en condiciones anaerobias. El biogas generado en los rellenos sanitarios tiene un contenido de metano del 55% y un 35% de bioxido de carbono. El 10% restante se compone de vapor

  11. Auto generation plant of Artigas landfill (Bilbao, Spain); Planta de autogeneracion electrica del vertedero de Artigas (Bilbao)

    Energy Technology Data Exchange (ETDEWEB)

    Carreras, N.; Dorronsoro, J.L.

    1996-07-01

    The disposition of MSW in the landfill generates a mixture of gases or {sup b}iogas{sup ,} its primary content is methane (50-60%) which has a very important energetic value, that can be very useful. In this sense, the present work point out the characteristics of the auto generation electrical plant of Artigas landfill, just like the results of the analytical study of the past two years. In this project which was partly funded by the UE, have participated Excmo. Ayuntamiento de Bilbao, EVE and CIEMAT. (Author) 6 refs.

  12. Solar thermal power plants for heat and electricity generation; Presentacion de plantas termosolares para generacion de calor y energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Estrada Cajigal, V [Solartronic S. A. de C. V., Cuernavaca (Mexico); Manzini, F; Sanchez, A [Laboratorio de Energia Solar (IIM-UNAM), Temixco (Mexico)

    1993-12-31

    Solar thermal technology is presented for concentration into a point for the production of heat and energy in small and large scale, emphasis is made on the capacity for the combination with current technologies using fossil fuels for electricity generation and process steam, increasing the global efficiency of the power plants and notably reducing the pollutants emission to the air during the insolation hours. It is successfully compared with other solar-thermal technologies. [Espanol] Se presenta la tecnologia termosolar de concentracion puntual para produccion de calor y de energia en pequena y gran escala, se enfatiza su capacidad de combinacion con las tecnologias actuales que utilizan combustibles fosiles para produccion de electricidad y vapor de proceso, aumentando la eficiencia global de las plantas y reduciendo notablemente sus emisiones contaminantes a la atmosfera durante las horas de insolacion. Se le compara exitosamente con otras tecnologias termosolares.

  13. Solar thermal power plants for heat and electricity generation; Presentacion de plantas termosolares para generacion de calor y energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Estrada Cajigal, V. [Solartronic S. A. de C. V., Cuernavaca (Mexico); Manzini, F.; Sanchez, A. [Laboratorio de Energia Solar (IIM-UNAM), Temixco (Mexico)

    1992-12-31

    Solar thermal technology is presented for concentration into a point for the production of heat and energy in small and large scale, emphasis is made on the capacity for the combination with current technologies using fossil fuels for electricity generation and process steam, increasing the global efficiency of the power plants and notably reducing the pollutants emission to the air during the insolation hours. It is successfully compared with other solar-thermal technologies. [Espanol] Se presenta la tecnologia termosolar de concentracion puntual para produccion de calor y de energia en pequena y gran escala, se enfatiza su capacidad de combinacion con las tecnologias actuales que utilizan combustibles fosiles para produccion de electricidad y vapor de proceso, aumentando la eficiencia global de las plantas y reduciendo notablemente sus emisiones contaminantes a la atmosfera durante las horas de insolacion. Se le compara exitosamente con otras tecnologias termosolares.

  14. The photovoltaic generators and the electric network; Los generadores fotovoltaicos y la red electrica

    Energy Technology Data Exchange (ETDEWEB)

    Arteaga Novoa, Oscar E.; Agredano Diaz, Jaime; Huacuz Villamar, Jorge M. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    The photovoltaic generators are analyzed as an option for the electricity supply. An analysis is made of the option that these systems be utilized in sites where it is difficult to extend the power lines an in sites where the electric service already exists, such as residences, commercial buildings, network support power stations, central power stations, all this in order that the photovoltaic systems interact with the electric network for the generation of part of the energy consumed in these sites. In order that the photovoltaic systems can be interconnected with the electric network it is required: energy quality, protection and safety of the systems and persons and normativity for the interconnection. Some of the national programs of countries like Japan, United States of America and some organs of the Commission of the European Community are described. In conclusion, it is expected that the costs of this technology decrease so these systems can be widely utilized [Espanol] Se analizan los generadores fotovoltaicos como una alternativa para el suministro electrico. Se analiza la opcion de que estos sistemas se utilicen en lugares en donde es dificil extender la red electrica y en sitios en donde el servicio electrico ya existe, tales como: residencias, edificios comerciales, estaciones de apoyo a la red, estaciones centrales, esto con la finalidad de que el sistema fotovoltaico interactue con la red electrica a fin de generar parte de la energia que se consume en estos sitios. Para que los sistemas fotovoltaicos puedan estar interconectados con la red electrica se requiere: calidad de la energia, proteccion y seguridad de los sistemas y personas, y normatividad para la interconexion. Se describen algunos programas nacionales de paises como Japon, Estados Unidos y algunos organismos de la Comision de Comunidades Europeas. En conclusion, se espera que los costos de esta tecnologia disminuyan para que estos sistemas puedan ser ampliamante utilizados

  15. The photovoltaic generators and the electric network; Los generadores fotovoltaicos y la red electrica

    Energy Technology Data Exchange (ETDEWEB)

    Arteaga Novoa, Oscar E; Agredano Diaz, Jaime; Huacuz Villamar, Jorge M [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    The photovoltaic generators are analyzed as an option for the electricity supply. An analysis is made of the option that these systems be utilized in sites where it is difficult to extend the power lines an in sites where the electric service already exists, such as residences, commercial buildings, network support power stations, central power stations, all this in order that the photovoltaic systems interact with the electric network for the generation of part of the energy consumed in these sites. In order that the photovoltaic systems can be interconnected with the electric network it is required: energy quality, protection and safety of the systems and persons and normativity for the interconnection. Some of the national programs of countries like Japan, United States of America and some organs of the Commission of the European Community are described. In conclusion, it is expected that the costs of this technology decrease so these systems can be widely utilized [Espanol] Se analizan los generadores fotovoltaicos como una alternativa para el suministro electrico. Se analiza la opcion de que estos sistemas se utilicen en lugares en donde es dificil extender la red electrica y en sitios en donde el servicio electrico ya existe, tales como: residencias, edificios comerciales, estaciones de apoyo a la red, estaciones centrales, esto con la finalidad de que el sistema fotovoltaico interactue con la red electrica a fin de generar parte de la energia que se consume en estos sitios. Para que los sistemas fotovoltaicos puedan estar interconectados con la red electrica se requiere: calidad de la energia, proteccion y seguridad de los sistemas y personas, y normatividad para la interconexion. Se describen algunos programas nacionales de paises como Japon, Estados Unidos y algunos organismos de la Comision de Comunidades Europeas. En conclusion, se espera que los costos de esta tecnologia disminuyan para que estos sistemas puedan ser ampliamante utilizados

  16. Electrochemical generation of energy: from the portable electronic devices to industrial plants; Generacion electroquimica de energia electrica: de los dispositivos electronicos portatiles a las plantas industriales

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Varela, Javier [Centro de Investigacion y de Estudios Avanzados (CINVESTAV), Unidad Saltillo (Mexico)

    2006-10-15

    This article proposes the electrical energy generation via electrochemistry as substitute of petroleum and discusses on the development of low and high temperature fuel cells fed by diverse types of fuels: electrolyte fuel cells of polymeric membrane, PEM cells H{sub 2}/O{sub 2}, cell of direct alcohol consumption, PEM cells and bio-fuel cells, SOFC cells and bio-fuel cells. It presents its constitution, operation principles, and use plausibility, present situation in the market, advantages and disadvantages, as well as already made cell insertion projects. [Spanish] Este trabajo propone la generacion de energia electrica via electroquimica como sustituto del petroleo y discurre sobre el desarrollo de celdas de combustible de baja y alta temperatura alimentadas por diversos tipos de combustibles: celdas de combustible de electrolito de membrana polimerica, celda PEM H{sub 2}/O{sub 2}, celda de consumo directo de alcohol, celdas PEM y biocombustibles, celdas de combustible de oxido solido y biocombustibles. Expone su constitucion, principios de operacion, plausibilidad de uso, situacion actual en el mercado, ventajas y desventajas, asi como proyectos de insercion de celdas ya realizados.

  17. First multivendor scheme in CFE to protection of 400 kV transmission line, using optical TC's, digital relays and bus IEC 61850-9-2; Primer esquema multivendedor en CFE para proteccion de linea de transmision de 400 kV, utilizando TC's opticos, relevadores digitales y bus IEC 61850-9-2

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Colon, V.R; Rasgado, J.P [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Lara C, H; Melendez, C; Juarez, N [Subdireccion de Transmision, Comision Federal de Electricidad (Mexico)

    2013-03-15

    This paper presents the details of design, installation and putting into service in the Comision Federal de Electricidad (CFE), of the first multi-vendor scheme that exists in the world, for the protection of a 400kV transmission line, which uses optical current transformers and digital relays IEC 61850-9-2. This system arises as a pilot project of the Subdireccion de Transmision of the CFE with the Instituto de Investigaciones Electricas (IIE). To ensure success in the implementation of the protection scheme, CFE joined a team coordinated by the Instituto de Investigaciones Electricas (IIE)involving nine international companies and a university. Pilot protection scheme is in operation under continuous monitoring, in one of the transmission lines of CFE that interconnect Manuel Moreno Torres with El Juile substations. The construction features, the challenges that were overcome and the first results obtained in operation are presented below. [Spanish] Este articulo presenta los detalles del diseno, instalacion y puesta en servicio en la Comision Federal de Electricidad (CFE) del primer esquema multivendedor que existe en el mundo, para la proteccion de una linea de transmision de 400kV, que utiliza transformadores de corriente opticos y relevadores digitales IEC 61850-9-2. Este sistema surge como un proyecto piloto de la Subdireccion de Transmision de la CFE con el Instituto de Investigaciones Electricas (IIE). Para asegurar el exito en la implementacion del esquema de proteccion, la CFE integro un equipo de trabajo coordinado por el Instituto de Investigaciones Electricas (IIE) en el que participaron 9 empresas internacionales y una universidad. El esquema de proteccion piloto, se encuentra en operacion bajo monitoreo continuo, en una de las lineas de transmision de la CFE que interconecta las subestaciones de Manuel Moreno Torres y El Juile. Las caracteristicas de construccion, los retos que fueron vencidos y los primeros resultados obtenidos en su operacion se

  18. Computerized procedure for protection coordination in distribution primary circuits; Procedimiento computarizado para coordinacion de protecciones en circuitos primarios de distribucion

    Energy Technology Data Exchange (ETDEWEB)

    Carrillo, Victor M; Velazquez Sanchez, Raul [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    Nowadays, the method employed to study the protection coordination are based in the hand outlining of curves time- current and in the visual comparison in log sheets. Due to the large amount of distribution circuits, the engineer makes a considerable effort to perform this type of studies, which besides are routinist and time consuming. In this article a program for the computer aided design for the protection coordination in primary distribution circuits is presented. Such a program -carried out in the Transmission and Distribution Department of the Power Systems Division of the Instituto de Investigaciones Electricas (IIE)- substitutes in an efficient manner, the manual procedures that are performed in the protection coordination studies. The coordination principles, suggested by the equipment manufacturers, were respected, trying, at the same time, to keep the procedures of the Comision Federal de Electricidad personnel (CFE) emerged from the field experience. The algorithm basically consists of an iterative process in the selection of the adjustments taking as a reference the of three-phase short- circuit and of phase to ground, values, as well as the operating times. [Espanol] Actualmente, los metodos que se emplean para estudiar la coordinacion de protecciones se basan en el trazado manual de curvas de tiempo-corriente y en la comparacion visual sobre hojas logaritmicas. Debido a la gran cantidad de circuitos de distribucion, el ingeniero hace un esfuerzo considerable para realizar este tipo de estudios, los que ademas, son rutinarios y tardados. En este articulo, se presenta un programa para el diseno asistido por computadora del proceso de coordinacion de protecciones en circuitos primarios de distribucion. Dicho programa -realizado en el Departamento de Transmision y Distribucion, de la Division de Sistemas de Potencia, del Instituto de Investigaciones Electricas (IIE)- sustituye de manera eficaz los procedimientos manuales que se efectuan en los estudios

  19. Computerized procedure for protection coordination in distribution primary circuits; Procedimiento computarizado para coordinacion de protecciones en circuitos primarios de distribucion

    Energy Technology Data Exchange (ETDEWEB)

    Carrillo, Victor M.; Velazquez Sanchez, Raul [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1986-12-31

    Nowadays, the method employed to study the protection coordination are based in the hand outlining of curves time- current and in the visual comparison in log sheets. Due to the large amount of distribution circuits, the engineer makes a considerable effort to perform this type of studies, which besides are routinist and time consuming. In this article a program for the computer aided design for the protection coordination in primary distribution circuits is presented. Such a program -carried out in the Transmission and Distribution Department of the Power Systems Division of the Instituto de Investigaciones Electricas (IIE)- substitutes in an efficient manner, the manual procedures that are performed in the protection coordination studies. The coordination principles, suggested by the equipment manufacturers, were respected, trying, at the same time, to keep the procedures of the Comision Federal de Electricidad personnel (CFE) emerged from the field experience. The algorithm basically consists of an iterative process in the selection of the adjustments taking as a reference the of three-phase short- circuit and of phase to ground, values, as well as the operating times. [Espanol] Actualmente, los metodos que se emplean para estudiar la coordinacion de protecciones se basan en el trazado manual de curvas de tiempo-corriente y en la comparacion visual sobre hojas logaritmicas. Debido a la gran cantidad de circuitos de distribucion, el ingeniero hace un esfuerzo considerable para realizar este tipo de estudios, los que ademas, son rutinarios y tardados. En este articulo, se presenta un programa para el diseno asistido por computadora del proceso de coordinacion de protecciones en circuitos primarios de distribucion. Dicho programa -realizado en el Departamento de Transmision y Distribucion, de la Division de Sistemas de Potencia, del Instituto de Investigaciones Electricas (IIE)- sustituye de manera eficaz los procedimientos manuales que se efectuan en los estudios

  20. Evaluation and diagnosis of the cathodic protection of ducts in the left margin of the Tonala River of the Superintendencia General de Ductos Minatitlan; Evaluacion y diagnostico de la proteccion catodica en la margen izquierda del Rio Tonala de la Superintendencia General de Ductos Minatitlan

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez N, Miguel A; Malo T, Jose M; Munoz Ledo C, Ramon; Uruchurtu C, Jorge; Castrejon G, Rafael [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Sanchez G, Luis; Algarra M, Raul; Abreu L, Emilio [Gerencia de Mantenimiento, Pemex (Mexico)

    2003-07-01

    The present study contains the measurements obtained as a part of the evaluation of the protection system of ducts located in the left margin of the Tonal River, made by the Gerencia de Materiales y Procesos Quimicos of the Instituto de Investigaciones Electricas (IIE) during the last trimester of year 2001. Also, the measurements of potential in conditions of instantaneous ignition and extinguished in measuring posts of the duct in Rights of Way (DDV) Tonala-Nudo Teapa 23 are studied, in order to determine the real protection level reached by the cathodic protection system, the possible unprotected zones and the possible corrective measures that lead to a safe operation of the ducts. [Spanish] El presente estudio contiene las mediciones obtenidas como parte de la evaluacion del sistema de proteccion de los ductos ubicados en la margen izquierda del rio Tonala, realizadas por la Gerencia de Materiales y Procesos Quimicos del Instituto de Investigaciones Electricas (IIE) durante el ultimo trimestre del ano 2001. Asimismo, se tratan las mediciones de potencial en condiciones de encendido y apagado instantaneo en postes de medicion del ducto en los Derechos De Via (DDV) Tonala-Nudo Teapa 23, con el proposito de determinar el nivel real de proteccion alcanzado por el sistema de proteccion catodica, las posibles zonas desprotegidas y las posibles medidas correctivas que conduzcan a una operacion segura de los ductos.

  1. Updates of the fire protection system of the Juzbado Nuclear Fuel Fabrication Plant; Actualizaciones del Sistema de Proteccion Contra Incendios de la Fabrica de Combustible Nuclear de Juzbado

    Energy Technology Data Exchange (ETDEWEB)

    Dorado, P.; Palomo, J. J.; Romano, A.

    2015-07-01

    The Juzbado Nuclear Fuel Fabrication Plant fire protection system is one of the most important safety system of the plant. Every year, a large part of the annual investment is employed to improve this system, to update its technology, in order to improve detection and extinction capability to minimize fire risk. Over the last few years, several improvement projects have been carried out that focused on fire detection technology update and on optimization of local detectors integration with a centralized control system, as well as on an advanced public address system, which used clear and unambiguous messages improving personnel response to a plant evacuation. Planned projects and those, which are currently under development, focus on improving passive fire protection means as well as fire protection of key emergency response equipment s such as emergency diesel generators and fire extinguishing bombs. (Author)

  2. Management program of cables and electrical conductions in operating nuclear power plant; Programa de gestion de cables y conducciones electricas en C. N. en Operacion

    Energy Technology Data Exchange (ETDEWEB)

    Perez Pereira, J.

    2012-07-01

    The management of cables and electrical conductions of a nuclear power plant is an activity very important during making the original design and subsequent design modifications, by the cable volume and nuclear safety regulations. During the design and construction of the Nuclear Power Plants, the late XX century, this work was carried out using manual procedures. The introduction of new technology provides users the ability to create relational databases for data according to the needs. Also tools and IT programs develop for the management of these databases with more reliability and a major number of possibilities at the moment of handling the available information. This paper aims to expose advances and developments in this field and present the methodology and lessons learned.

  3. Fuel cycle management by the electric enterprises and spanish nuclear Power plants; Gestion del ciclo de combustible por las empresas electricas y centrales nucleares espanolas

    Energy Technology Data Exchange (ETDEWEB)

    Celma, E. M.; Gonzalez, C.; Lopez, J. V.; Melara, J.; Lopez, L.; Martinez, J. C.; Culbras, F.; Blanco, J.; Francia, L.

    2015-07-01

    The Nuclear Fuel Group reports to the Technology Committee of the UNESA Nuclear Energy Committee, and is constituted by representatives of both the Spanish Utilities and the Nuclear Power Plants. The Group addresses the nuclear plant common issues in relation to the operation and management of the nuclear fuel in their different stages of the Fuel Cycle. The article reviews the activities developed by the Group in the Front-End, mainly in the monitoring of international programs that define criteria to improve the Fuel Reliability and in the establishment of common bases for the implementation of changes in the regulation applying the nuclear fuel. Concerning the Back-End the Group focuses on those activities of coordination with third parties related to the management of used fuel. (Author)

  4. Determination of leveled costs of electric generation for gas plants, coal and nuclear; Determinacion de costos nivelados de generacion electrica para plantas de gas, carbon y nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Alonso V, G.; Palacios H, J.C.; Ramirez S, J.R.; Gomez, A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: galonso@nuclear.inin.mx

    2005-07-01

    The present work analyzes the leveled costs of electric generation for different types of nuclear reactors known as Generation III, these costs are compared with the leveled costs of electric generation of plants with the help of natural gas and coal. In the study several discount rates were used to determine their impact in the initial investment. The obtained results are comparable with similar studies and they show that it has more than enough the base of the leveled cost the nuclear option it is quite competitive in Mexico. Also in this study it is also thinks about the economic viability of a new nuclear power station in Mexico. (Author)

  5. Information system of industrial security and environmental protection (SISPA) of PEMEX; Sistema de informacion de seguridad industrial y proteccion ambiental (SISPA) de PEMEX

    Energy Technology Data Exchange (ETDEWEB)

    Carrisoza B, Vicente; Bernal M, Hector M [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Cortazar F, Segio [Petroleos Mexicanos (Mexico)

    2002-07-01

    The Management of Supervision of Processes (GSP) in collaboration with the Management of Control and Instrumentation (GCI) of the Instituto de Investigaciones Electricas (IIE), has developed a system able to respond in a opportune and coordinated way to the attention and handling of emergencies, optimization of the number of reports and its content, reduction of the time in which the reports of industrial security and environmental protection arrive at their destiny, diminution of the manual process in the elaboration of reports and information and, finally, able to automatically calculate the associated performance indicators related to the efficiency of actions in each one the involved areas. [Spanish] La Gerencia de Supervision de Procesos (GSP) en colaboracion con la Gerencia de Control e Instrumentacion (GCI) del Instituto de Investigaciones Electricas (IIE), ha desarrollado un sistema capaz de responder de manera oportuna y coordinada a la atencion y manejo de emergencias, optimizacion del numero de reportes y su contenido, reduccion del tiempo en que los reportes de seguridad industrial y proteccion ambiental llegan a su destino, disminucion del proceso manual en la elaboracion de reportes e informes y, finalmente, capaz de calcular automaticamente los indicadores de desempeno asociados a la eficiencia de las acciones en cada una las areas involucradas.

  6. System for the measurement and detection of electric energy losses (SIM-IV); Sistema de medicion y deteccion de perdidas de energia electrica (SIM-IV)

    Energy Technology Data Exchange (ETDEWEB)

    Vidrio L, Gilberto; Gomez L, Martin J; Castan L, Roberto [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2004-07-01

    this is a system of the non-invasive type, it does not interfere with the operation of the electrical circuits. [Spanish] Las companias de electricidad de todo el mundo sufren, en mayor o menor grado, de perdidas de energia electrica. Un gran porcentaje de estas perdidas se debe, principalmente, a apropiaciones indebidas de energia. Los consumidores, mediante practicas ilicitas como tomas clandestinas y alteracion del funcionamiento de los medidores, llevan a cabo el robo de energia. Para tratar de aliviar la problematica de perdidas de energia electrica, en su mayoria por ilicitos, las companias de electricidad han implementado una o mas acciones. Entre las mas importantes estan: Inspeccion visual de las instalaciones de medicion. Su proposito es verificar el estado de las protecciones tradicionales del medidor, como son sellos y anillos de seguridad. Equipos de deteccion. Son registradores de consumo de energia y de fallas en conductores, se utilizan para detectar desviaciones en los patrones de consumo y derivaciones o conexiones ilicitas a la acometida de energia electrica o a la red secundaria de distribucion. Analisis estadistico de consumos. Muchas companias de electricidad han adaptado sus sistemas de procesamiento de lecturas de consumos para detectar desviaciones en los patrones de consumo de los clientes. Esto pudiera corresponder a situaciones anormales. Dado que este pais no es ajeno a la problematica de perdidas de energia, en el Instituto de Investigaciones Electricas se desarrollo un Sistema de Medicion y Deteccion de Perdidas de Energia Electrica (SIM-IV) como resultado del conocimiento de la problematica obtenido de los proyectos en el area de medicion y de la interaccion a traves de reuniones de trabajo con personal de la Comision Federal de Electricidad (CFE) y de Luz y Fuerza del Centro (LyFC), en el que se aplicaron conceptos y tecnologia avanzada de medicion de variables electricas. El SIM-IV es un sistema orientado a la medicion de consumos y la

  7. The rebranding of Electrica Soluziona SA - a case study

    Directory of Open Access Journals (Sweden)

    Monica GOMOESCU

    2016-07-01

    Full Text Available This article intends to present the design and implementation stages of a rebranding campaign that took place in the Electrica Soluziona SA company. The rebranding targets a company that provides consultancy services and software solutions and that underwent a change of its main shareholders structure, as it was taken over by Indra Group. After being taken over by Indra, Electrica Soluziona has considerably enlarged its product portfolio and the market segments targeted. Thus, it was mandatory to define a complex rebranding campaign. The rebranding process was not determined only by the broadening of activity, but also by the change of visual identity elements, along with the desire of repositioning.

  8. The Instituto de Investigaciones Electricas fluidized bed combustor; El combustor de lecho fluidizado del Instituto de Investigaciones Electricas

    Energy Technology Data Exchange (ETDEWEB)

    Milan Foressi, Julio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1991-12-31

    After synthesizing the most important aspects of the combustion technology in fluidized bed, the experimental combustor developed at the Instituto de Investigaciones Electricas (IIE) is described, as well as the test results of the experiences carried out with coal from Rio Escondido, Coahuila. [Espanol] Tras sintetizar los aspectos mas importantes de la tecnologia de combustion en lecho fluidizado, se describe el combustor experimental desarrollado en el Instituto de Investigaciones Electricas (IIE), asi como los resultados de las experiencias realizadas con carbon proveniente de Rio Escondido, Coahuila.

  9. The Instituto de Investigaciones Electricas fluidized bed combustor; El combustor de lecho fluidizado del Instituto de Investigaciones Electricas

    Energy Technology Data Exchange (ETDEWEB)

    Milan Foressi, Julio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1992-12-31

    After synthesizing the most important aspects of the combustion technology in fluidized bed, the experimental combustor developed at the Instituto de Investigaciones Electricas (IIE) is described, as well as the test results of the experiences carried out with coal from Rio Escondido, Coahuila. [Espanol] Tras sintetizar los aspectos mas importantes de la tecnologia de combustion en lecho fluidizado, se describe el combustor experimental desarrollado en el Instituto de Investigaciones Electricas (IIE), asi como los resultados de las experiencias realizadas con carbon proveniente de Rio Escondido, Coahuila.

  10. The Nuclear Safety Council's Instruction IS-30 on program requirements of fire protection at nuclear power plants; La instruccion IS-30 del consejo de Seguridad Nuclear sobre requisitos del programa de proteccion contraincendios en centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Peco, J.

    2015-07-01

    The Nuclear Safety Councils Instrumentation IS-30 is the standard that establishes the fire protection program requirements for the Spanish nuclear power plants with operating license in order to satisfy the two fire protection objectives, which are the adoption of the defense-in-depth principle for fire protection and, by fire area confinement, to ensure that one train of components needed to achieve and maintain the safe shutdown conditions is free of fire damage, and that radioactive liberation is minimized. (Author)

  11. Quality assurance applied to Radiological Protection Program of CPHR - Centro de Proteccion Y Higiene de las Radiaciones; Aseguramiento de la calidad aplicado al programa de proteccion radiologica del CPHR - Centro de Proteccion y Higiene de las Radiaciones

    Energy Technology Data Exchange (ETDEWEB)

    Marrero Garcia, M.; Jova Sed, L.; Domenech Nieves, H.; Hernandez Sainz, A. [Centro de Proteccion y Higiene de las Radiaciones, La Habana (Cuba)

    2001-07-01

    The quality assurance in establishment that use ionizing radiation sources, is according to international recommendations of radiation protection programs. This work intends to present the experience of the Centro de Proteccion y Higiene de las Radiaciones (CPHR), in the implementation of requirements of quality in their Radiological Protection Program.

  12. Super compacting of drums with dry solid radioactive waste in the nuclear power plant of Laguna Verde;Super compactacion de bidones con desecho radiactivo solido seco en la central nucleo electrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez G, R.; Lara H, M. A.; Cabrera Ll, M.; Verdalet de la Torre, O., E-mail: marco.lara@cfe.gob.m [Comision Federal de Electricidad, Central Nucleoelectrica de Laguna Verde, Carretera Nautla-Cardel Km. 42.5, Alto Lucero, Veracruz (Mexico)

    2009-10-15

    The nuclear power plant of Laguna Verde located in the Gulf of Mexico, completes in this 2009, nineteen years to produce by nuclear means 4.78% of the electric power that Mexico requires daily. During this time, the Unit 1 has generated more of 88.85 million mega watt-hour and the Unit 2 more of 69.48 million mega watt-hour with an availability average of 83.55%. Derived of their operation cycles, the nuclear power plant has generated (as any other installation of its type) radioactive wastes of low activity that at the moment are temporarily stored in the site. Due to the life cycle of the nuclear power plant, actually has become necessary to begin a project series focused to continue guaranteeing the storage of these wastes, guarantee that is a license requirement for the operation of this nuclear installation before the National Commission of Nuclear Security and Safeguards. The Federal Commission of Electricity beginning a project that allows continue guaranteeing space of sufficient storage for the wastes that the nuclear power plant of Laguna Verde could generate for the rest of its useful life, this project consisted on a process of physical volume reduction of dry solid radioactive wastes denominated super compacting, it has made possible to reduce the volume that these wastes occupy in the temporary storage noted Dry Solid Radioactive Wastes Deposit located inside the site that occupies the nuclear power plant of Laguna Verde. This work presents the super compacting results, as well as a description of the realization of this task until concluding with the super compacting of 5,854 drums with dry solid radioactive waste of low activity. We will enunciate which were the radiological controls that the Department of Radiological Protection of the nuclear power plant of Laguna Verde applied to this work that was realized for first time in Mexico and the nuclear power plant. (Author)

  13. San Juanico, BCS, Mexico, hybrid electric plant renewable energies in the rural communities development; Planta electrica hibrida San Juanico, B.C.S., Mexico, las energias renovables en el desarrollo de las comunidades rurales

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Rios, Serafin [Gerencia de Proyectos Geotermoelectricos, Comision Federal de Electricidad (Mexico)

    1999-08-01

    The hybrid electric plant of San Juanico, B.C.S., Mexico, is described in terms of its environmental goals, operating process and contribution to the development of that rural community of the Baja California Peninsula. San Juanico hybrid electric plant is organized in three electrical generation systems that work in parallel: one uses solar energy, another wind energy and a third one uses diesel fuel. [Spanish] Se describe la planta hibrida de San Juanico, BCS, Mexico, en terminos de los objetivos ambientales que condujeron a su realizacion, asi como de su proceso operativo y de la participacion que tiene en el desarrollo de esa comunidad rural de la peninsula de Baja California, Mexico. La planta hibrida de San Juanico esta constituida por tres sistemas de generacion de electrcicidad que operan en paralelo: uno utiliza energia radiante del sol, otro energia del viento y un tercero utiliza diesel.

  14. System for the measurement and detection of electric energy losses (SIM-IV); Sistema de medicion y deteccion de perdidas de energia electrica (SIM-IV)

    Energy Technology Data Exchange (ETDEWEB)

    Vidrio L, Gilberto; Gomez L, Martin J; Castan L, Roberto [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2004-07-01

    this is a system of the non-invasive type, it does not interfere with the operation of the electrical circuits. [Spanish] Las companias de electricidad de todo el mundo sufren, en mayor o menor grado, de perdidas de energia electrica. Un gran porcentaje de estas perdidas se debe, principalmente, a apropiaciones indebidas de energia. Los consumidores, mediante practicas ilicitas como tomas clandestinas y alteracion del funcionamiento de los medidores, llevan a cabo el robo de energia. Para tratar de aliviar la problematica de perdidas de energia electrica, en su mayoria por ilicitos, las companias de electricidad han implementado una o mas acciones. Entre las mas importantes estan: Inspeccion visual de las instalaciones de medicion. Su proposito es verificar el estado de las protecciones tradicionales del medidor, como son sellos y anillos de seguridad. Equipos de deteccion. Son registradores de consumo de energia y de fallas en conductores, se utilizan para detectar desviaciones en los patrones de consumo y derivaciones o conexiones ilicitas a la acometida de energia electrica o a la red secundaria de distribucion. Analisis estadistico de consumos. Muchas companias de electricidad han adaptado sus sistemas de procesamiento de lecturas de consumos para detectar desviaciones en los patrones de consumo de los clientes. Esto pudiera corresponder a situaciones anormales. Dado que este pais no es ajeno a la problematica de perdidas de energia, en el Instituto de Investigaciones Electricas se desarrollo un Sistema de Medicion y Deteccion de Perdidas de Energia Electrica (SIM-IV) como resultado del conocimiento de la problematica obtenido de los proyectos en el area de medicion y de la interaccion a traves de reuniones de trabajo con personal de la Comision Federal de Electricidad (CFE) y de Luz y Fuerza del Centro (LyFC), en el que se aplicaron conceptos y tecnologia avanzada de medicion de variables electricas. El SIM-IV es un sistema orientado a la medicion de consumos y la

  15. Estimation of requirements of eolic energy equivalent to the electric generation of the Laguna Verde nuclear power plant; Estimacion de requerimientos de energia eolica equivalente a la generacion electrica de la Central Nucleoelectrica de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Garcia V, M.A.; Hernandez M, I.A. [Facultad de Ingenieria, Division de Ingenieria Electrica, UNAM, 04510 Mexico D.F. (Mexico)]. E-mail: maiki27@yahoo.com; Martin del Campo M, C. [Facultad de Ingenieria, Laboratorio de Analisis en Ingenieria de Reactores Nucleares, UNAM, Paseo Cuauhnahuac 8532, 62550 Jiutepec, Morelos (Mexico)

    2004-07-01

    The advantages are presented that have the nuclear and eolic energy as for their low environmental impact and to the human health. An exercise is presented in the one that is supposed that the electric power generated by the Laguna Verde Nuclear Power plant (CNLV), with capacity of 1365 M W, it should be produced by eolic energy when in the years 2020 and 2025 the units 1 and 2 of the CNLV reach its useful life and be moved away. It is calculated the number of aero generators that would produce the electric power average yearly of the CNLV, that which is equal to install eolic parks with capacity of 2758 M W, without considering that it will also be invested in systems of back generation to produce electricity when the aero generators stops for lack of wind. (Author)

  16. 15 years of production of electric energy of the Laguna Verde power plant, its plans and future; 15 anos de produccion de energia electrica de la Central Laguna Verde, sus planes y futuro

    Energy Technology Data Exchange (ETDEWEB)

    Rivera C, A [CFE, Central Laguna Verde, Km. 42.5 Carretera Cardel-Nautla, Veracruz (Mexico)

    2005-07-01

    In the year 2005 Laguna Verde power plant reaches 15 years of producing electric power in Mexico arriving to but of 100 million Megawatts-hour from their beginning of commercial activities. The Unit 1 that entered at July 29, 1990 and the Unit 2 at April 10, 1995, obtaining the Disposability Factors from their origin is: 84.63% in Unit 1 and 83.67% in Unit 2. The march of the X XI century gives big challenges of competition to the Laguna Verde Central, with the possible opening of the electric market to private investment, for their Goals and Objectives of a world class company, taking the evaluation system and qualification of the World Association of Nuclear Operators (WANO) that promotes the Excellence in the operation of the nuclear power stations in all their partners. This Association supports the development of programs that allow the monitoring of the behavior in Safety Culture, Human fulfilment, Equipment reliability, Industrial Safety, Planning, Programming and Control, Personalized Systematic Training, and the use of the Operational experience in the daily tasks. The present work tries to explain the system of evaluation/qualification of WANO, the definition of Goals and Objectives to reach the excellence and of the programs, it will present the Program of the Reliability of Equipment with its main actions the productivity. (Author)

  17. Towards a distributed electric generation scheme with non-conventional energies; Hacia un esquema de generacion electrica distribuida con energias no convencionales

    Energy Technology Data Exchange (ETDEWEB)

    Huacuz Villamar, Jorge M. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    Several factors contributed to the existence of large electric systems as we know them today, such as: the increase of the electric demand by the advancement of the industrial development, the appearance of electric equipment, and household devices and by the advancement in the engineering systems, just to mention a few of them. With all this, the third part of the World population still does not have access to the electricity service. The efforts that the small electric enterprises perform to carry the service up to the site where it is required, every day time becomes more expensive and less effective. Exhausted by the weight of a huge economic debt, many electric utilities of the developing countries find each time more difficult to obtain financing to extend the power lines. This situation becomes still more serious with the present privatization scheme of the electric utilities. Although new technologies are being developed to counteract the negative effects caused by the large electricity generation power plants, the society seems to begin to show preferences for more benign to the environment options. The scheme of distributed generation can be given in to modalities: By means of isolated systems in remote sites, where there is not access to the conventional services; and with systems interconnected with the electric network where this is available [Espanol] Varios factores contribuyeron a la aparicion de los grandes sistemas electricos como los conocemos hoy en dia, tales como: el crecimiento de la demanda electrica por el avance del desarrollo industrial, la aparicion de equipos electricos y aparatos electrodomesticos y por avances en la ingenieria de los sistemas, por mencionar algunos. Con todo ello, la tercera parte de la poblacion mundial no tiene aun acceso al servicio electrico. Los esfuerzos que realizan las companias electricas para llevar el servicio hasta donde se requiere, resultan cada vez mas costosos y menos efectivos. Agobiadas por el peso

  18. Sun, wind and electric generation; Sol, viento y generacion electrica

    Energy Technology Data Exchange (ETDEWEB)

    Huacuz Villamar, Jorge M. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1995-12-31

    A description is made of the electric generation known as the photovoltaic-wind power hybrid systems at the generation station of X-Calak which is located in the zone known as Punta Herrero-X-Calak Corridor, in the Southern coast of the Quintana Roo State. This is a technology in development, in which the solar and the wind energy are combined, to offer an alternative of electric generation that can be economical, reliable and of low impact on the environment. Mention is made of the experiences gathered in this station as well as the results obtained [Espanol] Se describe la tecnologia de generacion electrica conocida como sistemas hibridos fotovoltaico-eolico en la planta generadora de X-Calak, la cual esta localizada en la zona conocida como el corredor Punta Herrero-X-Calak, en la costa sur del estado de Quintana Roo. Esta es una tecnologia en desarrollo, en donde se combina la energia solar y energia eolica, para ofrecer una alternativa de generacion electrica que pretende ser economica, confiable y de bajo impacto sobre el medio ambiente. Se mencionan las experiencias obtenidas en esta planta asi como los resultados obtenidos

  19. Sun, wind and electric generation; Sol, viento y generacion electrica

    Energy Technology Data Exchange (ETDEWEB)

    Huacuz Villamar, Jorge M [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    A description is made of the electric generation known as the photovoltaic-wind power hybrid systems at the generation station of X-Calak which is located in the zone known as Punta Herrero-X-Calak Corridor, in the Southern coast of the Quintana Roo State. This is a technology in development, in which the solar and the wind energy are combined, to offer an alternative of electric generation that can be economical, reliable and of low impact on the environment. Mention is made of the experiences gathered in this station as well as the results obtained [Espanol] Se describe la tecnologia de generacion electrica conocida como sistemas hibridos fotovoltaico-eolico en la planta generadora de X-Calak, la cual esta localizada en la zona conocida como el corredor Punta Herrero-X-Calak, en la costa sur del estado de Quintana Roo. Esta es una tecnologia en desarrollo, en donde se combina la energia solar y energia eolica, para ofrecer una alternativa de generacion electrica que pretende ser economica, confiable y de bajo impacto sobre el medio ambiente. Se mencionan las experiencias obtenidas en esta planta asi como los resultados obtenidos

  20. Wind energy for electricity generation; Generacion electrica con energia del viento

    Energy Technology Data Exchange (ETDEWEB)

    Huacuz Villamar, Jorge M; Borja Diaz, Marco Antonio R. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-09-01

    A description is made of electricity generation utilizing wind energy (Eoloelectric Generation). The case of Mexico is reviewed in respect to this technology, mentioning a small power plant of 1.5 Megawatts installed by the Comision Federal de Electricidad in the zone of La Ventosa in the State of Oaxaca. Mention is made of the possible causes why Mexico has not advanced in this type of power plants for power generation as in other countries like Germany, Spain and India. The advance in these countries is shown as well as the growth statistics of the wind power in the world. It is concluded that there is not in Mexico a strategy for wind energy utilization for electricity generation in spite of the potential benefits this technology offers [Espanol] Se describe el caso de la generacion electrica utilizando la energia del viento (Generacion Eoloelectrica). Se aborda el caso de Mexico respecto a esta tecnologia, mencionando una pequena central de 1.5 Megawatts (MW) instalada por la Comision Federal de Electricidad (CFE) en la zona de la Ventosa, Oaxaca. Se mencionan las posibles causas por las que en Mexico este tipo de centrales de generacion de energia no ha avanzado como en otros paises, por ejemplo: Alemania, Espana y la India. Se muestran los avances de estos paises, asi como una estadistica del crecimiento de la generacion eoloelectrica en el mundo. Se concluye en que no existe en Mexico una estrategia para la generacion eoloelectrica a pesar de los beneficios potenciales que ofrece esta tecnologia

  1. The Physical Protection of Nuclear Material; Proteccion Fisica Delos Materiales Nucleares

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-09-15

    Physical protection against the theft or unauthorized diversion of nuclear materials and against the sabotage of nuclear facilities by individuals or groups has long been a matter of national and international concern. Although responsibility for establishing and operating a comprehensive physical protection system for nuclear materials and facilities within a State rests entirely with the Government of that State, it is not a matter of indifference to other States whether and to what extent that responsibility is fulfilled. Physical protection has therefore become a matter of international concern and co-operation. The need for international cooperation becomes evident in situations where the effectiveness of physical protection in one State depends on the taking by other States also of adequate measures to deter or defeat hostile actions against nuclear facilities and materials, particularly when such materials are transported across national frontiers [French] La proteccion fisica contra el robo o la desviacion no autorizada de materiales nucleares y contra el sabotaje de las instalaciones nucleares por parte de individuos o de grupos ha sido durante largo tiempo motivo de preocupacion nacional e internacional. Aunque la obligacion de crear y hacer funcionar un sistema completo de proteccion fisica para las instalaciones y materiales nucleares en el territorio de un Estado determinado incumbe enteramente al Gobierno de dicho Estado, el que esa obligacion se cumpla o no, y si se cumple, en que medida o hasta que punto, es cosa que no deja indiferentes a los demas Estados. De aqui que la proteccion fisica se haya convertido en motivo de interes y cooperacion internacional. La necesidad de cooperacion internacional se hace evidente en los casos en que la eficacia de la proteccion fisica en el territorio de un Estado depende de que otros Estados tomen tambien medidas apropiadas para evitar o hacer fracasar los actos hostiles dirigidos contra instalaciones y

  2. Sistema automatizado para la realización de pruebas funcionales a las protecciones electrónicas CELCOR

    Directory of Open Access Journals (Sweden)

    Rodolfo García Bermúdez

    2006-01-01

    Full Text Available Se realiza el diseño e implementación de un sistema automatizado que permite hacer las pruebas funcionales a las protecciones electrónicas por sobrecorriente para equipos de refrigeración producidas en el Laboratorio Científico Productivo perteneciente a la Universidad de Holguín "Oscar Lucero Moya". Para ello se realizó un estudio de las especificaciones funcionales que reclama el fabricante de las protecciones, que hizo posible definir un grupo de pruebas que verifican dichas especificaciones, se emplean módulos de adquisición de datos conectados por medio de una interfaz RS485 a la computadora y se hizo el diseño de la electrónica necesaria para la adaptación de las señales a estos módulos. El sistema informático permite realizar las pruebas a seis protecciones al mismo tiempo, cuyos resultados son almacenados en una base de datos. Adicionalmente puede realizarse la caracterización de los transformadores de corriente utilizados como sensores en las protecciones. El sistema realiza un grupo de pruebas que son imposibles de forma manual, eleva la productividad de los técnicos, disminuye los costos asociados al consumo de electricidad y permite que al 100% de las protecciones que salen al mercado se le verifiquen todas sus especificaciones funcionales.

  3. Quality assurance applied to Radiological Protection Program of CPHR - Centro de Proteccion Y Higiene de las Radiaciones

    International Nuclear Information System (INIS)

    Marrero Garcia, M.; Jova Sed, L.; Domenech Nieves, H.; Hernandez Sainz, A.

    2001-01-01

    The quality assurance in establishment that use ionizing radiation sources, is according to international recommendations of radiation protection programs. This work intends to present the experience of the Centro de Proteccion y Higiene de las Radiaciones (CPHR), in the implementation of requirements of quality in their Radiological Protection Program

  4. Anaerobic/aerobic treatment for the waste water from the Instituto de Investigaciones Electricas installations; Tratamiento anaerobio-aerobio de las aguas residuales de las instalaciones del IIE

    Energy Technology Data Exchange (ETDEWEB)

    Arvizu Fernandez, Jose Luis [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    The waste water treatment plant of the Instituto de Investigaciones Electricas (IIE) is analyzed. This plant originally was a plant of the activated sludge type (aerobic development), process that consumes large amounts of energy and that produces residual sludge 5 or 6 times greater than the anaerobic processes. The methodology and the techniques utilized were base in the analysis of the existing plant introducing an anaerobic treatment and performing laboratory experimentation. The plant design parameters considered are described. The results show the benefits of treating by anaerobic means the waste waters since depuration are obtained on the order of 75%, as well as the reduction of resulting residual sludge and in energy consumption. A reduction of 60% to 70% can be attained if a combination of anaerobic and aerobic processes is utilized [Espanol] Se analiza la planta de tratamiento de aguas residuales del Instituto de Investigaciones Electricas (IIE). Esta planta era originalmente una planta de lodos activados (desarrollo aerobio), proceso que consume mucha energia y genera lodos residuales de 5 a 6 veces mas que los procesos anaerobios. La metodologia y las tecnicas utilizadas se basaron en el analisis de la planta de tratamiento existente en el IIE; en la caracterizacion residual del IIE; en la modificacion de la planta de tratamiento introduciendo un tratamiento anaerobio y efectuando experimentacion en laboratorio. Se describen los parametros de diseno de la planta considerados. Los resultados muestran los beneficios de tratar por medios anaerobios las aguas residuales ya que se obtienen depuraciones del orden del 75%, asi como la reduccion de lodos residuales resultantes y el consumo de energia, pueden reducirse de un 60% a un 70% si se utiliza la combinacion de los procesos anaerobios y aerobios

  5. Anaerobic/aerobic treatment for the waste water from the Instituto de Investigaciones Electricas installations; Tratamiento anaerobio-aerobio de las aguas residuales de las instalaciones del IIE

    Energy Technology Data Exchange (ETDEWEB)

    Arvizu Fernandez, Jose Luis [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    The waste water treatment plant of the Instituto de Investigaciones Electricas (IIE) is analyzed. This plant originally was a plant of the activated sludge type (aerobic development), process that consumes large amounts of energy and that produces residual sludge 5 or 6 times greater than the anaerobic processes. The methodology and the techniques utilized were base in the analysis of the existing plant introducing an anaerobic treatment and performing laboratory experimentation. The plant design parameters considered are described. The results show the benefits of treating by anaerobic means the waste waters since depuration are obtained on the order of 75%, as well as the reduction of resulting residual sludge and in energy consumption. A reduction of 60% to 70% can be attained if a combination of anaerobic and aerobic processes is utilized [Espanol] Se analiza la planta de tratamiento de aguas residuales del Instituto de Investigaciones Electricas (IIE). Esta planta era originalmente una planta de lodos activados (desarrollo aerobio), proceso que consume mucha energia y genera lodos residuales de 5 a 6 veces mas que los procesos anaerobios. La metodologia y las tecnicas utilizadas se basaron en el analisis de la planta de tratamiento existente en el IIE; en la caracterizacion residual del IIE; en la modificacion de la planta de tratamiento introduciendo un tratamiento anaerobio y efectuando experimentacion en laboratorio. Se describen los parametros de diseno de la planta considerados. Los resultados muestran los beneficios de tratar por medios anaerobios las aguas residuales ya que se obtienen depuraciones del orden del 75%, asi como la reduccion de lodos residuales resultantes y el consumo de energia, pueden reducirse de un 60% a un 70% si se utiliza la combinacion de los procesos anaerobios y aerobios

  6. Proceedings of the Fourth Session of Radioprotection of the patient; Actas de la 4. Jornada de Proteccion Radiologica al Paciente

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    The Radiology Argentine Society and the Radioprotection Argentine Society have organized the 4. Session of the Protection to the Patient, in order to inform to the technical and scientific community about the scopes of the radioprotection to the patient. The principal treated topics were the following: effects of the radiation in radiodiagnostic; radioprotection of the fetus and the pregnancy woman; radioprotection in dental radiology; radiological protection in TAC; radiation doses in radiodiagnostic; treatment of radiation injuries; fatal accidents in radiotherapy. [Spanish] La Sociedad Argentina de Radiologia, y la Sociedad Argentina de Radioproteccion, han organizado la 4ta. Jornada de Proteccion al Paciente, con el objeto de informar a la comunidad cientifico y tecnica sobre los alcances de la radioproteccion al paciente. Los principales temas tratados fueron los siguientes: efectos de la radiacion en radiodiagnostico; radioproteccion del feto y la mujer gestante; radioproteccion en radiologia odontologica; proteccion radioogica en TAC; dosis de radiacion en radiodiagnostico; tratamiento de lesiones por radiacion; accidentes fatales en radioterapia.

  7. The Physical Protection of Nuclear Material and Nuclear Facilities; Proteccion Fisica De Los Materiales Y Las Instalaciones Nucleares

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-06-15

    Physical protection against the theft or unauthorized diversion of nuclear materials and against the sabotage of nuclear facilities by individuals or groups has long been a matter of national and international concern. Although responsibility for establishing and operating a comprehensive physical protection system for nuclear materials and facilities within a State rests entirely with the Government of that State, it is not a matter of indifference to other States whether and to what extent that responsibility is fulfilled. Physical protection has therefore become a matter of international concern and co-operation. The need for international co-operation becomes evident in situations where the effectiveness of physical protection in one State depends on the taking by other States also of adequate measures to deter or defeat hostile actions against nuclear facilities and nuclear materials, particularly when such materials are transported across national frontiers [Spanish] La proteccion fisica contra el robo o la desviacion no autorizada de materiales nucleares y contra el sabotaje de las instalaciones nucleares por parte de individuos o grupos es motivo de preocupacion nacional e internacional desde hace mucho tiempo. Aunque la obligacion de crear y hacer funcionar un sistema completo de proteccion fisica de las instalaciones y materiales nucleares en el territorio de un Estado determinado incumbe exclusivamente al Gobierno de dicho Estado, el que esa obligacion se cumpla o no, y si se cumple, en que medida o hasta que punto, son cosas que no dejan indiferentes a los demas Estados. Por ello, la proteccion fisica se ha convertido en motivo de interes y cooperacion internacional. La necesidad de la cooperacion internacional se hace evidente en los casos en que la eficacia de la proteccion fisica en el territorio de un Estado depende de que otros Estados tomen tambien medidas apropiadas para evitar o hacer fracasar los actos hostiles dirigidos contra instalaciones y

  8. Qualitative aspects in the projects that are developed in the Instituto de Investigaciones Electricas; Aspectos cualitativos en los proyectos que se desarrollan en el Instituto de Investigaciones Electricas

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Neblina, Joaquin [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    1999-07-01

    The globalization of markets has generated more options of purchase of all type of goods and services, these options have generated opportunities and threats for all the companies and have looked for the satisfaction of the client as a strategy to remain or incursion into the global market. The Instituto de Investigaciones Electricas (IIE) is not the exception and therefore it looks for the identification of the qualitative aspects and to systematize its application in the projects that executes by means of the implantation of a system of quality assurance based on the series of ISO 9000 Standards. Some examples are described to identify the qualitative aspects of the projects that are developed in the Institute. [Spanish] La globalizacion de los mercados ha generado mas opciones de compra de todo tipo de bienes y servicios, dichas opciones han generado oportunidades y amenazas para todas las empresas y se ha buscado satisfacer al cliente como estrategia para permanecer o incursionar en el mercado global. El Instituto de Investigaciones Electricas (IIE) no es la excepcion y por lo tanto busca identificar los aspectos cualitativos y sistematizar su aplicacion en los proyectos que realiza mediante la implantacion de un sistema de aseguramiento de la calidad basado en la serie de normas ISO 9000. Se describen algunos ejemplos para identificar los aspectos cualitativos de los proyectos que se desarrollan en el instituto.

  9. Results of the benchmarking in radiological protection practices during fuel reloads in the nuclear power plants of Limerick (BWR) and Ginna (PWR) in the United States of North America; Resultados del benchmarking en practicas de proteccion radiologica durante recargas de combustible en las centrales nucleoelectricas de Limerick (BWR) y Ginna (PWR) en los Estados Unidos de Norteamerica

    Energy Technology Data Exchange (ETDEWEB)

    Lara H, M. A., E-mail: marco.lara@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Carretera Cardel-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2011-11-15

    The nuclear power plant of Laguna Verde, unique in our country, has been imposed several goals related with the continuous improvement of their acting; increase in the quantity of continuous days for operation cycle, improvement in the chemical indexes of the reactor coolant, improvement in the indexes of nuclear security, improvement in the indicators of industrial security, improvement in the standards of radiological protection, etc.; in this last item is precisely where is necessary to search creative solutions to be able to maintain the collective doses of the personnel so low as reasonably it is possible (ALARA) especially due to the last projects of extension of useful life of the nuclear power plant (zinc injection, noble metals and hydrogen) and of power increment of the nuclear power plant of Laguna Verde, same that represent in the short period an increment of collective dose and of exposition levels (until 200%) in very specific points of the primary systems of the reactor. (Author)

  10. Aspects of radiological safety and protection in the decontamination of the Benefit plant of uranium in Ciudad Aldama and in the storage of its residues in Pena Blanca, Chihuahua, Mexico; Aspectos de seguridad y proteccion radiologica en la descontaminacion de la planta de beneficio de uranio en Ciudad Aldama y en el almacenamiento de sus residuos en Pena Blanca, Chihuahua, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz C, M A [Facultad de Quimica, UNAM (Mexico)

    1998-07-01

    Between 1969 and 1971 the National Commission of Nuclear Energy and the Mining Fostering Commission operated coordinately a production plant of uranium and molybdenum concentrates (Benefit plant) at Ciudad Aldama, Chihuahua, Mexico. During two years of operation some 45 tonnes of uranium concentrate and approximately 35,000 tonnes of uranium wetlands were produced. These last were stored in a dam to 120 m. toward West of the plant. Due to the nearness of the population with respect to what was the Benefit plant and over all to the wetland dam, the objective of this work had two main aspects: On the one hand, to carry out the works of radiological decontamination of the benefit plant of uranium, according to the established normative by the Regulatory organization in matter of radiological safety and protection (CNSNS) for the population and the hard workers. After that the works mentioned were realized it was considered that the estate which comprises what was the Benefit plant did not reach the established criteria by the CNSNS for being considered of unrestricted use such estate and it was not allowed any type of construction in the zone which could be showed the residual contamination which remains there. On the other hand, to determine the site where could be stored the radioactive wastes generated by the radiological decontamination and the wetland mobilization for its definitive storage in benefit of the present population and of the future generations due to the radionuclides which are in a such material. The site more adequate technical and economically to storage the wastes generated by this activity was evaluated. Whereby studies about demography, use of soil and water, meteorology, hydrology and ecology were realized. The site selected being in the Pena Blanca mountains, Chihuahua, place where is located one of the uranium zones and the most important of the country. In this work, specific objectives also were treated such as: knowing the radiological

  11. Protecciones solares y su implicancia en la demanda energética: caso edificio público en Concepción, Chile

    OpenAIRE

    Jazmín Jara Córdova

    2015-01-01

    Determinar las ganancias solares en el vano-ventana con protecciones solares y analizar el comportamiento térmico en un edificio es un tema relativamente nuevo en el ámbito chileno. No obstante, el inadecuado manejo del control solar, en algunos casos, genera problemas de sobrecalentamiento al interior de la edificación. Esta investigación busca establecer un procedimiento que permita evaluar cuatro tipos de protecciones solares y analizar sus implicancias energéticas en un edificio público, ...

  12. Estudio de la coordinación de las protecciones por métodos computarizados aplicados al centro comercial mall del sur

    OpenAIRE

    Ramírez Rivera, Anthony; Inde Yanzapanta, Luis

    2011-01-01

    En la actualidad muchas de las empresas e industrias cuentan con sistemas eléctricos antiguos que no están sujetos a una coordinación de sus protecciones eléctricas o en su defecto cuentan con coordinaciones fuera de rangos establecidos y como producto de esto se tiene desde perdidas del fluido eléctrico innecesarias hasta incendios por fallas eléctricas no despejadas correctamente. El presente trabajo de investigación trata sobre la coordinación de las protecciones eléctricas en un sistema i...

  13. Electric grid in Spain: a private network of optical fiber with national coverage; Red electrica de Espana: una red privada de fibra optica con cobertura nacional

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, A.

    1995-12-31

    Red Electrica constructed a grid with optical fiber in 1989 for the grids of 400-220 Kv. In 1995 the length of the grid will be of 6.600 Km. This grid supplies the telecommunication advanced services and contributes in the efficiency and quality of different tasks of Red Electrica.

  14. Standardization for electric energy saving; Normalizacion para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Reyes Diaz, Arturo [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1994-12-31

    This work describes shortly the current legislation on the standardization; as well as the participation of the entities Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) and Programa de Ahorro de Energia (PAESE) in the consulting committees, for the elaboration of the Mexican official standards focussed to electric power saving. [Espanol] El presente trabajo, describe brevemente la legislacion actual sobre la normalizacion; asi como la participacion de las entidades Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) y Programa de ahorro de Energia (PAESE) en los comites consultivos, para la elaboracion de normas oficiales mexicanas enfocadas al ahorro de energia electrica.

  15. Standardization for electric energy saving; Normalizacion para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Reyes Diaz, Arturo [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1993-12-31

    This work describes shortly the current legislation on the standardization; as well as the participation of the entities Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) and Programa de Ahorro de Energia (PAESE) in the consulting committees, for the elaboration of the Mexican official standards focussed to electric power saving. [Espanol] El presente trabajo, describe brevemente la legislacion actual sobre la normalizacion; asi como la participacion de las entidades Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) y Programa de ahorro de Energia (PAESE) en los comites consultivos, para la elaboracion de normas oficiales mexicanas enfocadas al ahorro de energia electrica.

  16. Relation between the cathodic protection and the diagnosis of DCVG; Relacion entre la proteccion catodica y el diagnostico de DCVG

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez N, Miguel A; Malo Tamayo, Jose Maria [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Chavarria M, Rosalba; Duran E, Pablo [Petroleos Mexicanos (Mexico)

    2007-07-01

    The concern of the corrosion in buried pipes has increased with the course of time, the aging of the mechanical protection of the piping, results in defects in the coating, exposing the metal to the corrosive ground, in which the piping is lodged. If suitable levels of cathodic protection do not exist, the corrosion phenomenon in these defects is presented originating unexpected faults in the piping, increasing the costs of maintenance and repair, as well as the diminution in the safety during the operation, as much for the workers as for the communities near the installation of ducts. The technique of Direct Current Voltage Gradient (DCVG), besides locating the defects of the coating in a buried pipe (which are corrosion potential sites), determines corrosion status of the defects and its severity as far as the consumption of protection current that each of these absorbs. Nevertheless, all this information acquires a greater relevance, when it is correlated with the operating conditions of the cathodic protection systems, to be able to emit recommendations that lead to the mitigation or eradication of the corrosion problems, together with a good operation of the protection systems. [Spanish] La preocupacion por la corrosion en tuberias enterradas ha ido en aumento con el transcurso del tiempo, debido al envejecimiento de la proteccion mecanica de las tuberias, el cual da como resultado defectos en el recubrimiento, dejando expuesto el metal en suelo corrosivo, en el que se encuentra alojada la tuberia. Si no existen niveles de proteccion catodica adecuados, se propicia el fenomeno de corrosion en estos defectos, originando fallas inesperadas en las tuberias, incrementando a su vez los costos de mantenimiento y reparacion, asi como la disminucion en la seguridad durante la operacion, tanto para los trabajadores como para las comunidades cercanas a las instalaciones de ductos. La tecnica de Gradiente de Voltaje de Corriente Continua (DCVG), ademas de localizar los

  17. The electric tariff in the residential sector; Tarificacion electrica en el sector residencial

    Energy Technology Data Exchange (ETDEWEB)

    Sheinbaum Pardo, Claudia [Instituto de Ingenieria, Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1997-12-31

    The main objective of this paper is to make an historical revision and analyze the current condition of the electric tariffs in the Mexican residential sector and ask ourselves if the equalization of tariffs generates the possibility that the entire population has access to the electricity service. The document is divided into three parts. The first one presents the history and the tendencies of the tariffs in the domestic sector in Mexico since 1973 until 1996 and the current tariff structure. The second one describes the characteristics of the residential users and mention is made of how the increment of the electric tariffs would affect the various population sectors. The last part of this paper presents some tariff criteria, that take into account energy conservation measures [Espanol] El objetivo principal de este trabajo es hacer una revision historica y analizar la situacion actual de las tarifas electricas en el sector residencial mexicano y preguntarnos si la igualdad de tarifas genera la posibilidad de que toda la poblacion tenga acceso al servicio electrico. El documento se divide en tres partes. La primera presenta la historia y tendencias de las tarifas del sector domestico en Mexico desde 1973 hasta 1996 y la estructura tarifaria actual. La segunda describe las caracteristicas de los usuarios residenciales y se menciona como afectaria el incremento de las tarifas electricas a los distintos sectores de la poblacion. La ultima parte de este trabajo presenta algunos criterios de tarificacion, que toman en cuenta medidas de ahorro de energia

  18. Quality studies of the energy in the electric net of the gathering warehouse of reusable parts and contaminate oils of the nuclear power plant Laguna Verde; Estudios de calidad de la energia en la red electrica del almacen de acopio de partes reusables y aceites contaminados (CCAC) de la Central Nuclear Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Tijerina S, F.; Vargas A, A.; Cardenas J, J., E-mail: francisco.tijerina@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Subgerencia de Ingenieria, Carretera Cardel-Nautla Km 42.5, Veracruz (Mexico)

    2012-10-15

    In the industry exist the high costs by faults of electronic and electric equipment s, due to during the design process, installation, tests and operation of these equipment s, is not had appropriate detection equipment to carry out quality studies of the energy. These studies give an important support to know that occurs in an electric net, the cause of the anomalous behavior of the equipment s and this way to avoid the expensive faults carrying out necessary engineering adaptations in an electric net. The elements of the electricity that are determined are the tension, current and frequency that are inside acceptable operational parameters that facilitate the operation and constant operation of the equipment s, free of interruptions and failures. The application of the quality studies of the energy is growing little by little in Mexico for the problems solution in the equipment s. This field is also developing new techniques and technologies integrated in the equipment s for its monitoring detection and protection. The present work offers the results of the first Quality Study of the Energy in the nuclear power plant of Laguna Verde to solve the problem in the gathering warehouse of reusable parts and contaminate oils, in which the failure of the two radiation monitors of the gassy effluent of ventilation HVAC of the warehouse took place. (Author)

  19. Scenarios simulation of severe accident type small loss of coolant (Loca), with the code MELCOR version 2.1 for the nuclear power plant of Laguna Verde; Simulacion de escenarios de accidente severo tipo perdida de refrigerante (Loca) pequeno, con el codigo MELCOR version 2.1 para la central nucleo-electrica de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas V, J.; Mugica R, C. A.; Godinez S, V., E-mail: Jaime.cardenas@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Jose Ma. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2013-10-15

    In this work was carried out the analysis of two scenarios of the accident type with loss of coolant in a recirculation loop for a break with smaller ares to 0.1 ft{sup 2} (4.6 cm{sup 2}), which is classified according to their size like small Loca. The first simulated scenario was a small Loca without action of the emergency coolant injection systems, and the second was a small Loca with only the available system LPCS. This design base accident was taken into account for its relevance with regard to the damage to the core and the hydrogen generation. Was also observed and analyzed the response of the action of the ECCS that depend of the loss of coolant reason and this in turn depends of the size and type of the pipe break. The specified scenarios were simulated by means of the use of MELCOR model for the nuclear power plant of Laguna Verde that has the Comision Nacional de Seguridad Nuclear y Salvaguardias. (Author)

  20. 3D As-Built a documentation of the substation electrical power 400 KV; Documentacion 3D As-Built de una subestacion electrica de 400 KV

    Energy Technology Data Exchange (ETDEWEB)

    Sarti Fernandez, F.

    2011-07-01

    It's getting parameters of time, yields and products obtained, in order to have an objective reference to the possible application of this technique to substations of Red Electrica Espanola (REE).

  1. Work Report 1994-1995 Instituto de Investigaciones Electricas (Electrical Research Institute)

    International Nuclear Information System (INIS)

    Instituto de Investigaciones Electricas.

    1995-01-01

    The Instituto de Investigaciones Electricas (Electrical Research Institute) collaborates with the Comision Federal de Electricidad (Electricity Federal Commission) and with the public and private entities of the electric sector in the solution of scientific and technological problems. The activity of the Institute follows the lineaments of the Secretaria de Energia (Energy Secretariat) and is inside the frame of the programs of national modernization. This two-year report presents in seven sections the activities of the Institute; the sections are: 1. Importance of the IIE in the economic context of the Governmental sector. 2. Orientations of sectorial structural policy and main operation results. 3. Structural change, 1994-1995. 4. Research and Development, advances and results. 5. Budget and financial situation. 6. Statistical Annex. 7. Glossary

  2. Management and control of the electrical energy demand; Administracion y control de la demanda de la energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Johnson Controls [Comision Federal de Electricidad (Mexico)

    2005-07-01

    Administrative measures allow a reduction in the energy consumption, but not always in the electrical demand. Control measures allow a reduction in the billing of the electrical demand, but not always in the energy consumption. This is why it is explained in this document what management and control of the electrical demand is, as well as its control strategies, the control alternatives, the billing demand and at the same time graphical representations along with three practical cases on the management of demand in air compressors, air conditioning equipment and in corporative buildings are presented. [Spanish] La aplicacion de las medidas administrativas permite reducir el consumo de energia, pero no siempre la demanda electrica. La aplicacion de medidas de control permiten reducir la demanda electrica facturable, pero no siempre el consumo de energia. Es por eso que en este documento se explica que es la administracion y el control de la demanda electrica, sus estrategias de control, las alternativas de control, la demanda facturable, representaciones graficas y tres casos practicos sobre la administracion de demanda en compresores de aire, la administracion de demanda en aire acondicionado y la administracion de demanda en un edificio corporativo.

  3. Utilización de la simulación digital de protecciones eléctricas en los transformadores de potencia de las industrias niquelíferas de Moa

    Directory of Open Access Journals (Sweden)

    Antonio Martínez-García

    2005-03-01

    Full Text Available Las producciones de régimen continuo, como las empresas de níquel, requieren del trabajo estable de los Sistemas Eléctricos de Potencia (SEP frente a las averías, por lo que la instalación de protecciones que actúen u operen solo cuando éstas ocurran, desconectando rápidamente la zona o equipo averiado, se hace necesaria para evitar la propagación del daño por todo el SEP. El funcionamiento inadecuado de las protecciones incrementa los costos de producción en una industria; para garantizar el buen funcionamiento de las mismas se requieren herramientas como los simuladores digitales de protección. Este artículo trata de la modelación y simulación de las protecciones eléctricas que utilizan los transformadores de potencia en dos industrias niqueleras cubanas. Mediante el empleo de una Biblioteca Virtual de Protecciones Eléctricas creada en MATLAB/SIMULINK, se analiza el comportamiento de los sistemas de protecciones instalados en ambas industrias, se detectan deficiencias y se ofrecen las soluciones adecuadas para evitar tanto el aumento de los costos de mantenimiento como las desconexiones inoportunas u operaciones incorrectas.

  4. Protecciones solares y su implicancia en la demanda energética: caso edificio público en Concepción, Chile

    Directory of Open Access Journals (Sweden)

    Jazmín Jara Córdova

    2013-06-01

    Full Text Available Determinar las ganancias solares en el vano-ventana con protecciones solares y analizar el comportamiento térmico en un edificio es un tema relativamente nuevo en el ámbito chileno. No obstante, el inadecuado manejo del control solar, en algunos casos, genera problemas de sobrecalentamiento al interior de la edificación. Esta investigación busca establecer un procedimiento que permita evaluar cuatro tipos de protecciones solares y analizar sus implicancias energéticas en un edificio público, cuya infraestructura utilizada se justifica en el desconocimiento de nuevas exigencias que hará el Estado para este tipo de edificación. Para el caso de estudio se han determinado 37 escenarios con distintos factores solares modificados, definidos a través de cálculo manual, los cuales son evaluados bajo simulación dinámica (TAS. En primera instancia se analiza el comportamiento de dos recintos y posteriormente se obtienen los resultados en relación con la demanda energética del edificio. Las protecciones solares utilizadas (voladizos, retranqueo, lamas horizontales y verticales reducen la demanda de refrigeración de un 52 a 73% (aumentando la demanda de calefacción, sin embargo la demanda energética total (calefacción y refrigeración disminuye de un 24 a 31%.

  5. Seismic damage in the electrical substations of the Colima state; Dano sismico en las subestaciones electricas del estado de Colima

    Energy Technology Data Exchange (ETDEWEB)

    Mena H, Ulises; Lopez L, Alberto; Guerrero F, Vicente A. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2004-07-01

    On the 21 of January of 2003, at 20:06:36 hrs (Mexico center time) an earthquake occurred at the Pacific coast with a magnitude of 7.6 degrees in the Richter scale, whose epicenter was located near the state of Colima and it was felt in a large extent of the Mexican Republic. The earthquake caused numerous material damages in the structures (houses, churches, offices, etc) and vital lines, mainly in the infrastructure of the electrical sector of the region, leaving without electrical energy a large part of the nearby populations and some colonies of distant zones such as in Mexico City. The cause of the interruption of the electrical energy was due to the collapse of some of the equipment of 400 and 230 KV of the electrical transmission substations, among which are Manzanillo II and Colima II. With the experience acquired in the earthquake of October 9, 1995 in Manzanillo, in which also the facilities and equipment of the electrical substations were affected considerably, and as a part of the infrastructure project on the analysis of seismic risk of vital lines that is being developed at this moment at the Instituto de Investigaciones Electricas (IIE), it was decided to inspect the electrical substations of the zone, where the greater damages in the facilities and equipment were reported, to analyze and to determine the main causes of their failure. [Spanish] El 21 de enero de 2003, a las 20:06:36 hrs (hora del centro de Mexico) ocurrio un sismo en la costa del Pacifico con una magnitud de 7.6 grados en escala Richter, cuyo epicentro se localizo cerca del estado de Colima y se percibio en gran parte de la republica mexicana. El sismo causo cuantiosos danos materiales en las estructuras (viviendas, iglesias, oficinas, etc) y lineas vitales, principalmente en la infraestructura del sector electrico de la region, dejando sin energia electrica a gran parte de las poblaciones cercanas y algunas colonias de zonas lejanas como es la ciudad de Mexico. La causa del corte de

  6. Calculation of electromagnetic fields in electric machines by means of the finite element. Computational aspects; Calculo de campos electromagneticos en maquinas electricas mediante elemento finito. Aspectos computacionales

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Mario; De la Torre, Octavio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1990-12-31

    In this article are described the computational characteristics of the Package CALIIE 2D of the Instituto de Investigaciones Electricas (IIE), for the calculation of bi-dimensional electromagnetic fields. The computational implementation of the package is based in the electromagnetic and numerical statements formerly published in this series. [Espanol] En este articulo se describen las caracteristicas computacionales del paquete CALIIE 2D del Instituto de Investigaciones Electricas (IIE), para calcular campos electromagneticos bidimensionales. La implantacion computacional del paquete se basa en los planteamientos electromagneticos y numericos antes publicados en esta serie.

  7. Calculation of electromagnetic fields in electric machines by means of the finite element. Computational aspects; Calculo de campos electromagneticos en maquinas electricas mediante elemento finito. Aspectos computacionales

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Mario; De la Torre, Octavio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1989-12-31

    In this article are described the computational characteristics of the Package CALIIE 2D of the Instituto de Investigaciones Electricas (IIE), for the calculation of bi-dimensional electromagnetic fields. The computational implementation of the package is based in the electromagnetic and numerical statements formerly published in this series. [Espanol] En este articulo se describen las caracteristicas computacionales del paquete CALIIE 2D del Instituto de Investigaciones Electricas (IIE), para calcular campos electromagneticos bidimensionales. La implantacion computacional del paquete se basa en los planteamientos electromagneticos y numericos antes publicados en esta serie.

  8. The electric energy and the environment in Mexico. Volume 3; Energia electrica y medio ambiente en Mexico. Volumen 3

    Energy Technology Data Exchange (ETDEWEB)

    Quintanilla Martinez, Juan [eds.] [Universidad Nacional Autonoma de Mexico, Mexico, D. F. (Mexico)

    1997-12-31

    This document is the third one of three volumes of the 1. Seminar on the Current Conditions and Perspectives of the Electric Sector in Mexico, organized by the Programa Universitario de Energia and the Instituto de Investigaciones Economicas (University Program of Energy and the Institute of Economic Research), both of them agencies of the Universidad Autonoma de Mexico (UNAM). The titles of the three volumes are the following: Volume 1.- The opening of the Mexican Electric Sector to foreign investment. Volume 2.- Concrete innovation and technological learning experiences at the Luz y Fuerza del Centro enterprise. Volume 3.- The Electric Energy and the Environment in Mexico. This third volume covers the following subjects: Hydroelectricity, land use and water managing; the electric generation in Mexico and its environmental impact, the nuclear electricity and the handling of radioactive materials; the exposure to electromagnetic fields and its association with children`s leukemia; the energy in Mexico and the sustainable development; potential of electricity generation in large scale with wind power in Mexico; towards a scheme of distributed electric power generation with non-conventional energies and renewable energy sources in Mexico in the 21Century. These documents were elaborated by specialists of the electric sector, from the sector itself as well as from private and public academic entities [Espanol] Este documento constituye el tercero de tres volumenes del Primer Seminario sobre Situacion y Perspectivas del Sector Electrico en Mexico, organizado por el Programa Universitario de Energia y el Instituto de Investigaciones Economicas, ambas dependencias de la Universidad Nacional Autonoma de Mexico (UNAM). Los titulos de los tres volumenes son los siguientes: volumen 1: La apertura externa del sector electrico mexicano, volumen 2: Experiencias concretas de innovacion y aprendizaje tecnologico en la empresa Luz y Fuerza del Centro, volumen 3: Energia electrica

  9. Electric power conservation while using pumping systems; Conservacion de Energia Electrica en Sistemas de Bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Nambiar, P

    2007-01-15

    The pumping systems provide about 20 to 25 percent of energy which is necessary worldwide: it is fruitful to understand how to use electric power efficiently, to achieve the reduction regarding expenses a pumping system implies.It is essential to possess a better knowledge about the pumping system and its applications, in order to be able to use energy responsibly. If people do not how to operate this kind of systems properly, they will use inadequate equipment that will cause an energy waste. In addition it is important to know: alternative methods to meet variable demands, an adapted system to pump water requirements in order to ensure the pump work in its pumping point, and the life cycle system cost for the energy saving in the long term. [Spanish] En promedio del 20 al 25% de la energia necesaria en el mundo proviene de los sistemas de bombeo, por tal razon es importante saber como utilizar la energia electrica con eficiencia para asi lograr reducir los gastos que este tipo de sistemas implican. Para poder hacer un buen uso de la energia, es necesario que se tenga un conocimiento mayor del sistema de bombeo y aplicacion, ya que la ignorancia sobre esto exige el uso de aparatos que contribuyen al desperdicio de la energia; por otro lado tambien es esencial conocer metodos alternos para demandas variables, tener un sistema que se adapte a las necesidades de bombeo del agua para asegurarse de que cada bomba trabaje cerca de su punto de bombeo y finalmente conocer el costo del ciclo de vida del sistema para el ahorro de energia a largo plazo.

  10. Implementation of the procedure of high radiation of the forum about radiological protection in the health care environment; Implantacion del procedimiento de alta radiologica del foro sobre proteccion radiologica en el medio sanitario

    Energy Technology Data Exchange (ETDEWEB)

    Castro Novais, J.; Pardo Perez, E.; Molina Lopez, M. Y.; Ruiz Maqueda, S.; Maldonado Suarez, A.

    2013-07-01

    The objective of this work is to present the results of the implementation in our hospital the procedure of high radiological in patients treated with 131 I described in the document presented by the Forum on Radiation Protection in the Health Environment formed by the Consejo de Seguridad Nuclear and the Spanish societies of Fisica Medica and Proteccion Radiologica. (Author)

  11. Power quality. Analysis of the losses related to the tension and current distortion in the electric network; Calidad de la energia electrica. Analisis de las perdidas relacionadas con la distorsion de la tension y corriente de la red electrica

    Energy Technology Data Exchange (ETDEWEB)

    Rauch Sitar, Vladimir [Universidad Autonoma de Queretaro, Facultad de Ingenieria, Queretaro (Mexico)

    1994-12-31

    In recent times every day one speaks more about power quality and about the losses produced by the tension and current distortion. The distortion in the electric network and the consumption tend to keep on increasing, and each day there will be the need of applying more resources to handle it inside a reasonable range. In this article the situation of the power quality is analyzed in the most general case and also simplified for special cases. On base on the distortion coefficients of tension and current a matrix is created where the harmonics coefficients of tension as well as the current appear in an organized form an all of the elements of that matrix are analyzed. Some topological rules are created in order to give the simplest orientation in the complex situation. The article is useful to supervise the power quality in all of the typical cases and establish a base for a more detailed analysis. [Espanol] En los ultimos tiempos cada dia mas se esta hablando sobre la calidad de la energia electrica (Power Quality) y sobre las perdidas provocadas con este factor. La distorsion de la red electrica y del consumo tiene la tendencia de seguir aumentando y cada dia mas habra que dedicar mas recursos para manejarla dentro de un rango razonable. En el articulo presentado se analiza la situacion de la calidad de energia en caso mas general y tambien simplificada para los casos especiales. A base de coeficientes de distorsion, de tension y corriente se crea una Matriz donde figuran tanto los coeficientes de armonicas de tension como de corriente en una forma ordenada y se analizan todos los elementos de esta matriz. Se crean algunas reglas topologicas para dar la orientacion mas simple en la situacion compleja. El articulo sirve para dar supervision a la calidad de energia en todos los casos tipicos y establecer una base para el analisis mas detallado.

  12. Electric energy saving in the cellulose and paper industry; Ahorro de energia electrica en la industria de celulosa y papel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-12-31

    This paper delineates the results of the demonstration project for electric energy saving, which is one of the twenty four projects in which the Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) sponsors the diagnosis as well as the applied measures and the measures currently in application. Also the potential opportunity areas and the measures applied and in course of application, as well as the required investments and their recuperation periods. [Espanol] En este trabajo se describen los resultados del proyecto de demostracion de ahorro de energia electrica que es uno de los veinticuatro proyectos, en los que el Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) financia tanto el diagnostico como la aplicacion de medidas. Se presentan tanto las areas de oportunidad, potenciales y medidas aplicadas y en aplicacion, asi como las inversiones requeridas y los periodos de recuperacion de las mismas.

  13. System for the design of electrical distribution substations; Sistema para el diseno de subestaciones electricas de distribucion

    Energy Technology Data Exchange (ETDEWEB)

    Zayas Perez, Benjamin Eddie; Islas Perez, Eduardo; Bahena Rada, Jessica Liliana; Romero Lima, Jesus [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Sierra Rodriguez, Benjamin; Moreno Diaz, Humberto [Comision Federal de Electricidad (Mexico)

    2011-07-01

    The physical design of electric substations involves a variety of activities, such as developing, reviewing and performing modifications to different design proposals, estimating costs and producing documents to be integrated into an executive project. These activities are usually conducted at the Distribution Divisions of the Federal Electric Commission (CFE) through two separate processes: the development of engineering plans with computer-aided design software (CAD) and volumetric calculations for the initial budget using conventional spreadsheets. The documents are manually developed on an individual basis, without the existence of any functions to allow for automatically updating the design modifications of any of the plans. The corresponding initial budget becomes a lengthy and laborious process with the likelihood of inconsistencies among the documents. In order to optimize the design process for the public and electromechanical works of electric substations (ES) in a three-dimensional (3D) graphic environment, the IIE's Management of Process Supervision, in coordination with the CFE Distribution Subdivision, developed the System for the Design of Electric Substation Distribution (SDESD). This system makes use of the advantages of CAD3D technology to develop detail engineering, cost engineering to calculate initial budgets and virtual reality for three-dimensional interactive navigation. It is worth mentioning that this system is currently in the implementation phase at the CFE Distribution Subdivision. This article briefly describes the main stages in the development of the project, as well as the functioning and principal components of the system. [Spanish] El diseno fisico de subestaciones electricas implica una variedad de actividades, tales como elaborar, revisar y efectuar modificaciones de diferentes propuestas de diseno, estimar costos y producir documentos, para integrarlos como parte de un proyecto ejecutivo. Estas actividades usualmente se

  14. Electric energy saving in the cellulose and paper industry; Ahorro de energia electrica en la industria de celulosa y papel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-12-31

    This paper delineates the results of the demonstration project for electric energy saving, which is one of the twenty four projects in which the Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) sponsors the diagnosis as well as the applied measures and the measures currently in application. Also the potential opportunity areas and the measures applied and in course of application, as well as the required investments and their recuperation periods. [Espanol] En este trabajo se describen los resultados del proyecto de demostracion de ahorro de energia electrica que es uno de los veinticuatro proyectos, en los que el Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) financia tanto el diagnostico como la aplicacion de medidas. Se presentan tanto las areas de oportunidad, potenciales y medidas aplicadas y en aplicacion, asi como las inversiones requeridas y los periodos de recuperacion de las mismas.

  15. Hydraulic turbines uses for rural electric generation; Utilizacion de microturbinas para la generacion electrica en el medio rural

    Energy Technology Data Exchange (ETDEWEB)

    Genta, J [Facultad de Ingenieria, Instituto de Mecanica de Fluidos e Ingenieria Ambiental, Montevideo, (Uruguay); Nunes, V [Facultad de Ingenieria, Instituto de Ingenieria Electrica, Montevideo, (Uruguay)

    1994-07-01

    The micro turbines use for electric generation either in autonomous systems or in connection to the national net is presented like an alternative whose viability has been studied in the Agreement taken place between the UTE Administracion Nacional de Usinas y transmisiones Electricas y la Facultad de Ingenieria. The Agreement {sup S}tudy for the Installation of Micro turbines that initially considered areas far from the national electric net it extended then to near areas to the same one to analyze the cogeneration alternative. They were considered smaller and bigger powers than 1 MW and up to 5MW. For the whole study range a methodology is described of calculate primary, starting from a minimum of field information that allows a first estimate of viability of a certain place and the selection of the turbine type, for a later detailed study.

  16. The electric energy in Mexico and the sustainable development; La energia electrica en Mexico y el desarrollo sustentable

    Energy Technology Data Exchange (ETDEWEB)

    Campos Aragon, Leticia [Instituto de Investigaciones Economicas, Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1997-12-31

    This document explains the importance of the sustainable development in the electric energy, that is, that the technological advances in the electric sector do no hamper the future of the generations to come and generate potential problems such as: environmental pollution, unnecessary expenses in the realization of new technologies already executed. Mention is made of the relationship between nature and society, the ecological crisis, and the electric energy, seven points are given on how to control and treat waste waters, three points are given to handle and dispose of solid wastes, finally four points are given on the noise contamination control. It is concluded that the problem of reducing the environmental impact of the generation of electricity does not depend on the applied technology, since there are technological options for its solution, but on other more complex factors that deal with the generation of wealth, its distribution and the population growing [Espanol] En el presente documento se explica la importancia del desarrollo sustentable en la energia electrica, es decir que los avances tecnologicos en el sector energetico no entorpezcan el futuro de las generaciones venideras y generen posibles problemas como: contaminacion del medio ambiente, gastos innecesarios en la realizacion de las nuevas tecnologias realizadas. Se menciona la relacion entre la naturaleza y la sociedad, la crisis ecologica y la energia electrica, se dan siete puntos de como controlar y tratar aguas residuales, se proporcionan tres puntos para manejar y disponer de residuos solidos, por ultimo se dan cuatro puntos sobre el control de la contaminacion por ruido. Se concluye en que el problema de reducir el impacto ambiental por la generacion de electricidad no depende de la tecnologia empleada pues existen alternativas tecnologicas para su solucion, sino en otros aun mas complejos que tienen que ver con la generacion de la riqueza, su distribucion y el crecimiento de la poblacion

  17. Photovoltaic systems interconnected to the electric network; Sistemas fotovoltaicos interconectados a la red electrica

    Energy Technology Data Exchange (ETDEWEB)

    Agredano Diaz, Jaime [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2007-06-15

    . Enseguida, se muestra la solucion que le encontro el Gobierno del Estado a este problema para lo que fue necesaria la participacion del Instituto de Investigaciones Electricas (IIE). Esta participacion, se traduce en un proyecto que muestra la viabilidad de instalar sistemas fotovoltaicos interconectados a la red de la Comision Federal de Electricidad (CFE) en casas habitacion. Despues, se presenta una descripcion no solo de los elementos que conforman el sistema, sino tambien de la metodologia y el funcionamiento del mismo. Posteriormente, se presenta el efecto positivo, economicamente y ambientalmente hablando, que tuvo la instalacion del sistema en las 220 casas habitacion del fraccionamiento Valle de las Misiones, asi como las caracteristicas generales del mismo. Ademas, se presenta la manera de alcanzar un mayor impacto y cobertura del sistema. Finalmente, se presentan los auspiciadotes del proyecto: la Secretaria de Energia (SENER), la CFE, la Comision Reguladora de Energia (CRE), la Universidad Autonoma de Baja California (UABC), el IIE, el Banco de Desarrollo de America del Norte (BDAN) y el Gobierno del Estado de Baja California.

  18. Calculation of electromagnetic field in electric machines through the finite element: Electromagnetic modeling; Calculo de campos electromagneticos en maquinas electricas mediante elemento finito: Modelacion electromagnetica

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Mario F [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    In this article are presented the general characteristics of the electromagnetic phenomena that can be described by means of the software CALIIE-2D of the Instituto de Investigaciones Electricas (IIE) derived from a modeling based in the magnetic and electric potentials, always using the MKS rationalized units system. Closed regions are considered with axial or moving symmetry to incorporate the bi-dimensional behavior of the electromagnetic fields. The possibility of means with movement is also included. [Espanol] En este articulo se presentan las caracteristicas generales de los fenomenos electromagneticos que pueden describirse mediante el programa de computo CALIIE-2D, del Instituto de Investigaciones Electricas (IIE), que provienen de una modelacion basada en los potenciales magnetico y electrico, en esta se utiliza sistema MKS racionalizado de unidades. Se consideran regiones cerradas con simetria axial o traslacional para incorporar el comportamiento bidimensional de los campos electromagneticos, se incluye tambien la posibilidad de medios con movimiento.

  19. Calculation of electromagnetic field in electric machines through the finite element: Electromagnetic modeling; Calculo de campos electromagneticos en maquinas electricas mediante elemento finito: Modelacion electromagnetica

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Mario F. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    In this article are presented the general characteristics of the electromagnetic phenomena that can be described by means of the software CALIIE-2D of the Instituto de Investigaciones Electricas (IIE) derived from a modeling based in the magnetic and electric potentials, always using the MKS rationalized units system. Closed regions are considered with axial or moving symmetry to incorporate the bi-dimensional behavior of the electromagnetic fields. The possibility of means with movement is also included. [Espanol] En este articulo se presentan las caracteristicas generales de los fenomenos electromagneticos que pueden describirse mediante el programa de computo CALIIE-2D, del Instituto de Investigaciones Electricas (IIE), que provienen de una modelacion basada en los potenciales magnetico y electrico, en esta se utiliza sistema MKS racionalizado de unidades. Se consideran regiones cerradas con simetria axial o traslacional para incorporar el comportamiento bidimensional de los campos electromagneticos, se incluye tambien la posibilidad de medios con movimiento.

  20. Analysis methodology for economic technical feasibility studies in offshore electrical generation systems; Metodologia de analisis para estudios de factibilidad tecnica economica en sistemas de generacion electrica costa fuera

    Energy Technology Data Exchange (ETDEWEB)

    Fiscal Escalante, Raul [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2007-07-01

    An analysis methodology followed in the development of technique-economic feasibility studies of systems of electrical generation in offshore electrical installations is presented, including the obtaining of the curves of the turbine and generator performance, the technical considerations for the formulation of the operation scenes and the calculations of the economic evaluation of a real scenario. [Spanish] Se muestra una metodologia de analisis seguida en el desarrollo de estudios de factibilidad tecnica-economica de sistemas de generacion electrica en instalaciones electricas costa fuera, incluyendo la obtencion de las curvas de comportamiento de la turbina y el generador, las consideraciones tecnicas para la formulacion de los escenarios de operacion y los calculos de la evaluacion economica de un escenario real.

  1. Analysis of the generation of electric energy through the use of biogas obtained from sanitary fillings in Mexico; Analisis de la generacion de energia electrica a traves de biogas procedente de rellenos sanitarios en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Cerda Sauvage, Tania Kalinka [Facultad de Ingenieria, Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2004-06-15

    Through this work a theoretical analysis conducted for the use of biogas obtained from sanitary landfills for the generation of electrical energy is presented, as well as the evaluation of the main elements that limit or favor the development of this technology in our country. In the introductory part of this work are presented some causes considered have favored the development of technologies as the one proposed here. In the first part it is exposed what the biogas is and what conditions are necessary for its production, which explains the production of biogas in the sanitary landfills, in addition, describes the distribution of the solid residues that give raise to the present situation of the sanitary landfills and the biogas production process in these. The work continues with a description of the electrical energy generation process through the gas originated in sanitary landfills, indicating the necessary conditions in order that the filling complies with its basic functions; following our process until obtaining the final item, electrical energy. For the description of the process and to analyze some factors that take part, it is advisable to include the main aspects of a plant located in Monterrey that occupies this technology. This project shows project shows off in a tangible form the barriers that this technology faces, as well as its main advantages and disadvantages. Are exposed the limiting factors of this technology in technological, economic, political and social aspects, the barriers that can and must overcome as well as the reasons that justify the effort to overcome them. Finally are presented the conclusions it arrives, as well as the commentaries and suggestions in respect to the subject. [Spanish] A traves de este trabajo se expone un analisis teorico efectuado al uso de biogas extraido de rellenos sanitarios para la generacion de energia electrica, asi como evaluar los principales elementos que limitan o favorecen el desarrollo de esta

  2. Reliability of electric generation units by evaluating the loss of power and efficiency of turbines; Confiabilidad de las unidades de generacion electrica mediante la evaluacion de la perdida de potencia y eficiencia de las turbinas

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Solis, Jose Antonio; Cristalinas Navarro, Victor Manuel [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2012-07-01

    The aim of the specialized technical service to evaluate the loss of power and efficiency of an open steam turbine is to quantify these losses caused by the deterioration of internal seals, deterioration of the steam path geometry components (nozzles and blades) and increased roughness of the blades and nozzle surface due to erosion (steam, humidity and impacts) and, also, due to salts deposition. In the same way, to establish a set of recommendations, in order of importance by the attention of the Power Plant with the purpose of recovering the major quantity of power and efficiency lost by the steam turbine and assurance, by means of technical supervision of the activities set in the recommendations, and in accordance with CFE rules, international standards and the personal experience of the Instituto de Investogaciones Electricas (IIE), staff, an acceptable quality in rehabilitation of mechanical components such as the maintenance of the steam turbine itself. Using an application example, this paper describes, the methodology of execution of this kind of services. Also, the quality of the maintenance and the rehabilitation of the steam turbine components are quantified. [Spanish] El objetivo del servicio tecnico especializado para evaluar la perdida de potencia y eficiencia de una turbina de vapor abierta es cuantificar dichas perdidas a causa del deterioro de los sellos internos, del deterioro la geometria de referencia de los componentes del canal de vapor (alabes fijos y alabes moviles) y del aumento de la rugosidad de la superficie de los alabes a causa de la erosion (marcas de vapor, de humedad y de impactos) y de la deposicion de sales. Asimismo, establecer una serie de recomendaciones en orden prioritario para la atencion de la central, con el fin de recuperar la mayor parte de la potencia y eficiencia perdidas por la turbina y asegurando, mediante la supervision tecnica de las actividades resultantes de las recomendaciones y conforme a la normativa de la

  3. COORDINACIÓN DE LAS PROTECCIONES DE LA SUBESTACIÓN DE DISTRIBUCIÓN EN EL SISTEMA MILAGRO GUAYAS – LOS RÍOS

    OpenAIRE

    Quiroga Aguirre, Boris Adrian; Muñoz Cabello, Carlos Luis

    2015-01-01

    El presente trabajo desarrolla el estudio de la coordinación de protecciones aplicados a la subestación de distribución “MILAGRO SUR”, ubicada en el cantón Milagro. Partiendo primero desde la descripción de las instalaciones para conocer los elementos que la componen; posteriormente, se realiza un estudio de flujo de carga en condiciones de máxima y mínima carga y un estudio de cortocircuito de la subestación aplicados a la barra de 69kV y 13.8kV, esto nos servirá como datos preliminares para...

  4. Coordinación de las protecciones de la subestación de distribución en la península de Santa Elena

    OpenAIRE

    Fernández Chicas, Robinson David; Espinel Encalada, José Leonidas; Aguilar Sánchez, Yasmani Leonardo; Saavedra Mera, Juan

    2014-01-01

    El presente trabajo desarrolla el estudio de la coordinación de protecciones aplicados a la subestación de distribución “SALINAS”, ubicada en la península de Santa Elena. Partiendo primero desde la descripción de las instalaciones, para conocer los elementos que la componen; posteriormente, se realiza un estudio de flujo de carga en condiciones de máxima y mínima carga y un estudio de cortocircuito de la subestación aplicados a la barra de 69kV y 13.8kV, esto nos servirá como datos preliminar...

  5. Coordinación de las protecciones de la subestación de distribución en el sistema Durán norte

    OpenAIRE

    Tinoco Tinoco, Misael Patricio; Sanchez Yela, Darwin Horacio

    2016-01-01

    El presente trabajo desarrolla el estudio de la coordinación de protecciones aplicados a la subestación de distribución “DURÁN NORTE”, ubicada en el cantón Durán en la parte norte de la cuidad del mismo nombre. Partiendo primero desde la descripción de las instalaciones, para conocer los elementos que la componen; posteriormente, se realiza un estudio de flujo de carga en condiciones de máxima y mínima carga y un estudio de cortocircuito de la subestación aplicados a la barra de 69kV y 13.8kV...

  6. The Mexican electric industry under an opening triangle; La industria electrica mexicana bajo un triangulo de apertura

    Energy Technology Data Exchange (ETDEWEB)

    Suarez Guevara, Sergio [Instituto de Investigaciones Economicas, Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1997-12-31

    This document analyzes the electric industry in Mexico in its opening phase, which must be qualified as a strategic activity within the present and future becoming of the Mexican economy. The Mexican electric sector was framed within the National Project born out in the country`s Politic Constitution; where the State economic intervention is driven and induced, with its exclusive duty in strategic activities through public enterprises created for that purpose and as a support of Mexico`s economic and social welfare. Within the opening it should be pointed out the participation of the North American Free Trade Agreement (NAFTA), the Energy Program, the Development Program and Restructure of the Energy Sector 1995-2000 [Espanol] En el presente documento se analiza la industria electrica en Mexico en su fase de apertura, la cual debe calificarse como una actividad estrategica dentro del devenir presente y futuro de la economia mexicana. El sector electrico mexicano se enmarco dentro del Proyecto Nacional que nace en la Constitucion Politica del pais; donde se impulsa e induce la intervencion economica del Estado, con su quehacer exclusivo en actividades estrategicas, por medio de empresas publicas creadas para tal fin y en apoyo del bienestar economico y social de Mexico. Dentro de la apertura hay que senalar la participacion que tiene el Tratado de Libre Comercio, el Programa de Energia y el Programa de Desarrollo y Reestructuracion del Sector Energia 1995-2000

  7. Application of unimodal optic fiber to communications among electric substations; Aplicacion de fibra optica unimodal a comunicaciones entre subestaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Pinon, Fernando; Hernandez Juarez, Taide [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1992-07-01

    The utilization of the unimodal fiber optics technology in the electric power systems, represents one of the best communication options because of its multiple advantages, that results in a better coordination of the technical and administrative activities, needed to carry the electric energy from its generation site to the most remote locations. In this document a study, in accordance with the available options for the design of communication systems via unimodal optic fiber, is presented. With this technology, ties of more than 100 kilometers without the need of repeating stations, can be made. [Espanol] La utilizacion de la tecnologia de fibra optica unimodal en los sistemas electricos de potencia representa una de las mejores alternativas de comunicacion por sus multiples ventajas que se traducen en una mejor coordinacion de las acitividades tecnicas y administrativas necesarias para llevar la energia electrica desde el lugar de generacion hasta los puntos mas distantes. En este documento se presenta un estudio de acuerdo a las opciones disponibles para el diseno de sistemas de comunicacion por fibra optica unimodal. Con esta tecnologia se pueden realizar enlaces mayores que 100 km sin necesidad de repetidores.

  8. Projects of electrical energy saving in Costa Rica; Proyectos de ahorro de energia electrica en Costa Rica

    Energy Technology Data Exchange (ETDEWEB)

    Chinchilla, Henry [Compania Nacional de Luz y Fuerza, S.A., San Jose (Costa Rica)

    1999-07-01

    un adecuado aporte hacia la competitividad industrial, confort humano y proteccion del medio.

  9. Interconnection of industrial centers with the electric network of the public service; Interconexion de centros industriales con la red electrica del servicio publico

    Energy Technology Data Exchange (ETDEWEB)

    Rosales Sedano, Inocente; Lopez Velazquez, Juan Jose; Garcia Paredes, Job; Robles Pimentel, Edgar [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico); Garcia Alvarez, David; Guzman Camacho, Benigno [Petroleos Mexicanos (Mexico)

    2000-07-01

    The large industrial centers that have continuous production processes and consume high amounts of electrical energy, generally have their own power generation. The petrochemical complexes, the paper and steel factories and the sugar mills are examples of this type of centers. On the other hand, the new regulation for the generation of electrical energy that allows to the electrical energy interchange between private companies and the public network, has originated the necessity of connecting systems that formerly operated isolated. Since the original design of the isolated electrical systems was to operate in an independent form, making the interconnection can generate technical problems that must be analyzed and solved. In this paper, some experiences related with the behavior of electrical equipment when connected to operate with the public network, are presented. [Spanish] Los grandes centros industriales que tienen procesos de produccion continua y consumen altas cantidades de energia electrica, generalmente cuentan con generacion propia. Los complejos petroquimicos, las fabricas de papel y acero y los ingenios azucareros son ejemplos de este tipo de centros. Por otro lado, la nueva reglamentacion de generacion de energia electrica que permite el intercambio de energia electrica entre las companias privadas y la red publica, ha originado la necesidad de conectar sistemas que antes operaban aislados. Debido a que el diseno original de los sistemas electricos aislados fue trabajar en forma independiente, el realizar la interconexion puede generar problemas tecnicos que tienen que analizarse y resolverse. En este articulo, se presentan algunas experiencias relacionadas con el comportamiento del equipo electrico al operar conectado con la red publica.

  10. Efficient use of electric power in corporative 3M Mexico; Uso eficiente de la energia electrica en el corporativo 3M Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Perez, Alfredo; Quinones Bonilla, Antonio S. [3M Mexico, S.A. de C.V. (Mexico); Bustos Antunez, Jorge I; Reyes Arce, Manuel [Hines Interests, S.A. de C.V. (Mexico)

    2003-07-01

    It is not enough to count on with the state of the art technology for the daily operation of a building, the challenge is to be able to make a clear analysis and with attainable goals for the optimization of rational use of the electrical energy in the operation of intelligent buildings without affecting the comfort and productivity for users as well as the functionality and profitability for the owner. This went our base to carry out control strategies that helped the efficient use of the electrical energy, obtaining important savings without neglecting the operative part, of services and human within the property. It is thus, that 3M Mexico wanting to reach these purposes, conducted actions to improve the efficiency of the equipment in the following items: electric network, general lighting, air conditioning system, ventilation and extraction, hydropneumatic system, and sumps operation. [Spanish] No basta contar con la tecnologia de punta para la operacion diaria de un edificio, el reto es ser capaces de realizar un analisis claro y con metas alcanzables para la optimizacion de uso racional de la energia electrica en las operaciones de edificios inteligentes sin afectar el confort y productividad para usuarios asi como la funcionalidad y rentabilidad para el propietario. Esta fue nuestra base para llevar a cabo estrategias de control que ayudaron al uso eficiente de la energia electrica, obteniendo ahorros importantes sin descuidar la parte operativa, de servicios y humana dentro de la propiedad. Es asi, que 3M Mexico queriendo alcanzar dichos propositos, realizo acciones para mejorar la eficiencia de los equipos en los siguientes rubros: red electrica, iluminacion general, sistema de aire acondicionado, ventilacion y extraccion, sistema hidroneumatico, y operacion de carcamos.

  11. Experimental evaluation of the consumption of electrical energy of domestic refrigerators in Mexico; Evaluacion experimental del consumo de energia electrica de refrigeradores domesticos en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Arroyo Cabanas, Fernando Gabriel [Programa de Energia, Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico); Ambriz Garcia, Juan Jose; Paredes Rubio, Hernando Romero [Area de Ingenieria en Recursos Energeticos, Universidad Autonoma Metropolitana, Mexico, D.F. (Mexico)

    2004-06-15

    In this work the experimental methodology developed to carry out tests of the electrical energy of refrigerators consumption as norm NOM-015-ENER-2002 is described. The tests were made in the Laboratory of Controlled Environment of the Iztapalapa Unit of the Universidad Autonoma Metropolitana to a sample of old domestic refrigerators in operation. The results found show that the consumption of electrical energy of refrigerators of more than 10 years of age can be higher than 60% of what a modern refrigerator of high efficiency would consume, or 30% higher if the refrigerator was made between 1997 and 2002. With these results it is sustained, in a more complete way, the evaluation of the saving potential of the national electrical energy by the substitution of old domestic refrigerators by modern, as reported in a previous work. [Spanish] En este trabajo se describe la metodologia experimental desarrollada para efectuar pruebas del consumo de energia electrica a refrigeradores conforme la norma NOM-015-ENER-2002. Las pruebas se realizaron en el Laboratorio de Ambiente Controlado de la Unidad Iztapalapa de la Universidad Autonoma Metropolitana a una muestra de refrigeradores domesticos antiguos en operacion. Los resultados encontrados muestran que el consumo de energia electrica de refrigeradores de mas de 10 anos de antig�edad puede superior al 60% de lo que consumiria un refrigerador moderno de alta eficiencia, o superior en un 30% si el refrigerador fue fabricado entre 1997 y 2002. Con estos resultados se sustenta de manera mas completa la evaluacion del potencial de ahorro de energia electrica nacional por substitucion de refrigeradores domesticos antiguos por modernos reportado en un trabajo anterior.

  12. Demand curves of electric energy in domestic sector in two regions of Mexico; Curvas de demanda de energia electrica en sector domestico de dos regiones de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Maqueda Zamora, Martin Roberto; Sanchez Viveros, Luis Agustin [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2011-07-01

    In this work, is presented the analysis of residential consumption, regarding the temperature of two areas and types of electrical appliances. A shape characteristic of the load of the electrical energy is obtained for two geographical areas in Mexico. The consumption information was obtained from measurements in residential consumers and from the Mexican Utility. It is also shown the demand profile of the main residential appliances, obtained from smart metering equipment to separate the residential users' load profiles. It is shown the effect of the different variables analyzed on the electrical power consumption, mainly the type of equipment, the geographical localization, the weather (temperature, humidity and vegetation type). With the results attained, the definition of effective energy-saving programs and its effectiveness can be obtained. [Spanish] En este trabajo se presenta el analisis del consumo residencial considerando la temperatura de las dos areas y tipos de aparatos electricos. Se obtiene una forma caracteristica de la carga de energia electrica de dos areas geograficas de Mexico. La informacion sobre el consumo se obtuvo de mediciones en consumidores residenciales y de una empresa electrica mexicana. Tambien se muestra el perfil de demanda de los principales aparatos residenciales, derivado de equipos de medicion inteligentes para separar los perfiles de carga de usuarios residenciales. Se muestra el efecto de diferentes variables analizadas en el consumo de energia electrica, principalmente el tipo de equipo, la localizacion geografica, el clima (temperatura, humedad y tipo de vegetacion). Con los resultados alcanzados pueden definirse programas de ahorro de energia efectivos y lograr implantarlos.

  13. Methodology for evaluating the grounding system in electrical substations; Metodologia para la evaluacion del sistema de puesta a tierra en subestaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Torrelles Rivas, L.F [Universidad Nacional Experimental Politecnica: Antonio Jose de Sucre (UNEXPO), Guayana, Bolivar (Venezuela)]. E-mail: torrellesluis@gmail.com; Alvarez, P. [Petroleos de Venezuela S.A (PDVSA), Maturin, Monagas (Venezuela)]. E-mail: alvarezph@pdvsa.com

    2013-03-15

    The present work proposes a methodology for evaluating grounding systems in electrical substations from medium and high voltage, in order to diagnose the state of the elements of the grounding system and the corresponding electrical variables. The assessment methodology developed includes a visual inspection phase to the elements of the substation. Then, by performing measurements and data analysis, the electrical continuity between the components of the substation and the mesh ground is verified, the soil resistivity and resistance of the mesh. Also included in the methodology the calculation of the step and touch voltage of the substation, based on the criteria of the International IEEE standards. We study the case of the 115 kV Pirital Substation belonging to PDVSA Oriente Transmission Network. [Spanish] En el presente trabajo se plantea una metodologia para la evaluacion de sistemas de puesta a tierra en subestaciones electricas de media y alta tension, con la finalidad de diagnosticar el estado de los elementos que conforman dicho sistema y las variables electricas correspondientes. La metodologia de evaluacion desarrollada incluye una fase de inspeccion visual de los elementos que conforman la subestacion. Luego, mediante la ejecucion de mediciones y analisis de datos, se verifica la continuidad electrica entre los componentes de la subestacion y la malla de puesta a tierra, la resistividad del suelo y resistencia de la malla. Se incluye tambien en la metodologia el calculo de las tensiones de paso y de toque de la subestacion, segun lo fundamentado en los criterios de los estandares Internacionales IEEE. Se estudia el caso de la Subestacion Pirital 115 kV perteneciente a la Red de Transmision de PDVSA Oriente.

  14. Options of electric generation and sustainability; Opciones de generacion electrica y sustentabilidad

    Energy Technology Data Exchange (ETDEWEB)

    Martin del Campo M, C. [UNAM, Facultad de Ingenieria, Laboratorio de Analisis en Ingenieria de Reactores Nucleares, Paseo Cuauhnahuac 8532, Jiutepec, Morelos (Mexico)

    2004-07-01

    In this paper a study on the sustainability of the main electricity generation options is presented. The study is based on a matrix of sustainability indicators developed in Switzerland. A revision of some sustainability studies performed in countries with certain energy diversity and with experience in nuclear power plants operation, is done. Studies, in general, are performed for the power plant life cycle, taking into account economic aspects, fuel prices impact on electricity generation costs, fuel reserves indicators and material consumption. Air emission, waste production and human health impact data are also presented. All the results lead to confirm that nuclear energy has a high degree of sustainability vis a vis other options based on fossil fuels and renewable. Finally some comments are presented in order to highlight the importance that nuclear energy might have in the sustainable development of Mexico. (Author)

  15. ENFOQUE MULTIOBJETIVO DE LA MEJORA DE LA EFICIENCIA DE CENTRALES ELECTRICAS: ANALISIS ENERGETICO Y ECONOMICO

    Directory of Open Access Journals (Sweden)

    Ruiz, Ana B.

    2014-06-01

    Full Text Available The auxiliary services of power plants have raised their energy consumption given that, nowadays, power plants usually operate at partial loads. This paper presents a multiple criteria study about the efficiency improvement of the auxiliary services through a series of strategies. Besides the energy savings, two economic criteria are considered: the economic investment required and the Internal Rate of Return to maximize the profitability of the investment. In order to solve this multiobjective problem, we have developed a scheme which combines several approaches in order both to make use of the main advantages of each method and to progressively adapt the solution process to the decision maker’s preferences. Finally, we solve the multiobjective problem associated to a real case study using the scheme designed. With this case study, we show the usefulness of the scheme proposed, and we highlight the importance of an understandable feedback and an adaptive process.

  16. The Spanish energetic mix; prevision and historic evolution of the electric production structure; El mix energetico espanol; evolucion historica y prevista de la estructura de produccion electrica

    Energy Technology Data Exchange (ETDEWEB)

    Revuelta, J.; Lopez Sanz, R.

    2010-07-01

    This article describes the past and forecasted evolution of the electric production of the Spanish system (excluding the Spanish isolated systems), according to the records of the System Operator, Red Electrica de Espana, and the studies of its Network Planning department. The behaviour of the demand is analysed, as well as the evolution of the generation mix. The article expose the main recent changes the sector has undergone and points out the main future challenge it will face regarding the forecasted evolution of the demand, the integration of renewable energy sources, and the energy objectives established at European and national level. (Author)

  17. Supervisory control for hybrid systems of electrical generation based on fuzzy logic; Control supervisorio para sistemas hibridos de generacion electrica basado en logica difusa

    Energy Technology Data Exchange (ETDEWEB)

    Lagunas M, Javier; Ortega S, Cesar [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Caratozzolo M, Patricia [Instituto Tecnologico de Estudios Superiores de Monterrey, campus Cd. de Mexico (Mexico)

    2005-07-01

    The development and integration of hybrid systems of electrical generation (SHGE) of small capacity: The intention of these developments is its implementation in isolated or far away communities from conventional electric networks, that contribute in the own productive processes of these towns. As part of these work a system of control for their hybrid system wind-photovoltaic- internal combustion machine was developed that operates nowadays in a system installed in Pachuca, Hidalgo, Mexico. However, in the two past years, the GENC has worked, altogether with the Management of Control and Instrumentation of the Instituto de Investigaciones Electricas (IIE) and the Centro Nacional de Investigacion y Desarrollo Tecnologico (CENIDET) (National Center of Research and Technological Development), to incorporate an intelligent control technique in the regulation of the hybrid systems of wind-photovoltaic-machine of internal combustion type. Lemos de Pereira rises that the main problems of the present technology of the SHGE are related to the control and supervision of the power systems. The system that is in charge of the actions of load control and dispatch is denominated supervisory control. This controller supervises the operation of all the components, regulates the entry or exiting of operation of the generation systems, as well as the loads. [Spanish] El desarrollo e integracion de sistemas hibridos de generacion electrica (SHGE) de pequena capacidad. El proposito de estos desarrollos es su implementacion en comunidades aisladas o alejadas de la red electrica convencional, las cuales contribuyan en los procesos productivos propios de estos poblados. Como parte de dichos trabajos se desarrollo un sistema de control para su sistema hibrido eolico-fotovoltaico-maquina de combustion interna que opera actualmente en un sistema instalado en Pachuca, Hidalgo, Mexico. Ahora bien, en los dos ultimos anos, la GENC ha trabajado, en conjunto con la Gerencia de Control e

  18. Importance of the validation of saving technologies of electric power; Importancia de la validacion de tecnologias ahorradoras de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Valer Negrete, Adrian [Programa de Ahorro de Energia del Sector Electrico (PAESE), Comision Federal de Electricidad (Mexico)

    2003-07-01

    Within the Programs of Energy Saving it is fundamental the search and application of new technologies, with which this saving can be obtained, selected with base in their technical characteristics that allow to reduce to the consumptions and demands of power, without damaging the electric networks nor the transformers of the Comision Federal de Electricidad. It is important that the investments which are made count on attractive periods of capital recovery, in comparison with the useful life of the product, reason why the knowledge and price of the new technologies will be parameters to consider in an important manner, creating the need of conducting tests that verify the veracity of the information of the supplier, resulting in certain cases, the change of design of these technologies, so that thus they fulfill the engaged characteristics. This paper indicates the characteristics that the new saving technologies of electrical energy must fulfill and the tests and parameters to consider their evaluation. [Spanish] Dentro de los Programas de Ahorro de Energia es fundamental la busqueda y aplicacion de nuevas tecnologias, con las que se pueda obtener dicho ahorro, seleccionadas con base en sus caracteristicas tecnicas que permitan reducir los consumos y demandas de potencia, sin danar las redes ni transformadores de la Comision Federal de Electricidad. Es importante que las inversiones que se realicen cuenten con periodos de recuperacion de capital atractivos, comparados con la vida util del producto, por lo que el conocimiento y precio de las nuevas tecnologias seran parametros a considerar de manera importante, creandose la necesidad de realizar pruebas que verifiquen la veracidad de la informacion del proveedor, resultando en determinados casos, el cambio de diseno de dichas tecnologias, para que asi cumplan las caracteristicas prometidas. Este trabajo indica las caracteristicas que deben cumplir las nuevas tecnologias ahorradoras de energia electrica y las

  19. Research activities in the use of energy; Actividades de investigacion en el uso de la energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Covarrubias Ramos, Rogelio; Garcia Juarez, Francisco [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1999-12-31

    The use of energy is intimately related to the development and is found in the human activities of all types, consequently we could say that to a greater usage it must correspond a greater benefit. This paper carries on a comparative analysis of the Mexico`s energy efficiency versus industrialized countries; this analysis shows that while Mexico indicates a growing tendency, in the industrialized countries the tendency is to the drop, unmistakable sign of a better usage of the energy sources. It also makes evident that promoting the energy efficiency in Mexico will stimulate and regulate the energy conservation at National level, in the same way it is mentioned that an appropriate energy demand Management for the users as well as for the service providers, will diminish the peak demand, the adequate application of the electric rates at the actual conditions and the energy saving and the strategic load growth [Espanol] El uso de la energia esta intimamente relacionado con el desarrollo y se encuentra en las actividades humanas de todo tipo, de tal suerte que podriamos decir que a mayor uso debe corresponder un mayor beneficio. En este documento se realiza un analisis comparativo de la eficiencia energetica en Mexico contra paises industrializados; este analisis muestra que mientras Mexico indica una tendencia creciente, en los paises industrializados la tendencia es a la baja, signo inequivoco de un mejor uso de los energeticos, tambien hace ver que la promocion de la eficiencia energetica en Mexico estimulara y regulara el ahorro de energia a nivel nacional, de igual manera se menciona que una buena administracion de la demanda energetica tanto por los usuarios como los que prestan el servicio, reducira la demanda pico, la adecuacion de las tarifas electricas a las condiciones reales y el ahorro de los energeticos y el crecimiento estrategico de la carga

  20. Research activities in the use of energy; Actividades de investigacion en el uso de la energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Covarrubias Ramos, Rogelio; Garcia Juarez, Francisco [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    The use of energy is intimately related to the development and is found in the human activities of all types, consequently we could say that to a greater usage it must correspond a greater benefit. This paper carries on a comparative analysis of the Mexico`s energy efficiency versus industrialized countries; this analysis shows that while Mexico indicates a growing tendency, in the industrialized countries the tendency is to the drop, unmistakable sign of a better usage of the energy sources. It also makes evident that promoting the energy efficiency in Mexico will stimulate and regulate the energy conservation at National level, in the same way it is mentioned that an appropriate energy demand Management for the users as well as for the service providers, will diminish the peak demand, the adequate application of the electric rates at the actual conditions and the energy saving and the strategic load growth [Espanol] El uso de la energia esta intimamente relacionado con el desarrollo y se encuentra en las actividades humanas de todo tipo, de tal suerte que podriamos decir que a mayor uso debe corresponder un mayor beneficio. En este documento se realiza un analisis comparativo de la eficiencia energetica en Mexico contra paises industrializados; este analisis muestra que mientras Mexico indica una tendencia creciente, en los paises industrializados la tendencia es a la baja, signo inequivoco de un mejor uso de los energeticos, tambien hace ver que la promocion de la eficiencia energetica en Mexico estimulara y regulara el ahorro de energia a nivel nacional, de igual manera se menciona que una buena administracion de la demanda energetica tanto por los usuarios como los que prestan el servicio, reducira la demanda pico, la adecuacion de las tarifas electricas a las condiciones reales y el ahorro de los energeticos y el crecimiento estrategico de la carga

  1. Red Electrica de Espana S.A.. Instrument of regulation and liberalization of the Spanish electricity market (1944-2004)

    International Nuclear Information System (INIS)

    Garrues-Irurzun, Josean; Lopez-Garcia, Santiago

    2009-01-01

    To understand the regulation system of the Spanish electricity market it is first necessary to understand on the one hand the system of tariffs and prices, and on the other the organization of the market for high voltage distribution. This article is concerned with this second aspect and traces its history from 1944, this is because before that date it was not possible to speak of a truly national market, but rather only of regional monopolies. In the 1940s, with Franco's new political regime, and the development of the Spanish electricity sector, it became necessary to completely rethink business strategies in relation to competition and cooperation, as well as the regulatory function of the state. In the 1950s, the main feature of the sector was the system of business self-regulation permitted by the state. Throughout the remaining years of Franco's government state intervention was particularly focussed on the subject of tariffs, but with the onset of democracy the state was to involve itself in the transmission network as well. A debate began as to whether it should be run by a private or public operator. In this dispute were ranged, on the one hand, the economic policy concepts of the major parties (PSOE and PP), and against them the strategic interests of the companies. Although the high voltage transmission network was nationalized by the state in the mid-1980s, establishing a 'traditional' model of regulation, the 1990s saw the triumph of a market-based regulation, strongly influenced by the dominant ideas in the European Union, which has converted Red Electrica into a private company. Currently the TSO (Transmission System Operators) model has been extended to Portugal and has entered into competition-cooperation with the other models of the European electricity market. (author)

  2. Supervisory fussy control for an electric generating hybrid system; Control supervisorio difuso para un sistema hibrido de generacion electrica

    Energy Technology Data Exchange (ETDEWEB)

    Lagunas Mendoza, Javier

    2004-11-15

    the fuzzy supervisory controller were compared with a conventional controller. The results shows that the supervisory controller fulfills the three main objectives of the system operation: I) to reduce the fuel consumption of the back-up system, II) to reduce the depth of the discharge of the battery bank, and III) to keep fully charged the battery bank as much as possible in order to make a better use of the available free renewable energy sources. [Spanish] En este trabajo se presenta el desarrollo de un controlador supervisorio difuso para un sistema hibrido de generacion electrica (SHGE). En este trabajo se definio la configuracion y los elementos que componen el SHGE a utilizar, producto de la revision de configuraciones de sistemas hibridos propuestas actualmente. La configuracion del SHGE incluye: arreglos fotovoltaicos y aerogeneradores como fuentes de generacion renovable, una maquina de combustion interna como sistema de respaldo, un banco de baterias como medio de almacenamiento de energia, cargas electricas en corriente alterna y un inversor CD/CA para poder alimentarlas. Tambien a partir de la configuracion propuesta se buscaron y seleccionaron los modelos matematicos de los diferentes elementos del sistema. Se llevo a cabo la validacion de los modelos a traves de la comparacion de la salida contra datos reales obtenidos en un SHGE instalado en Pachuca. Con los modelos se llevo a cabo el desarrollo de un programa de simulacion para un SHGE en Matlab. Se determino la funcion principal del controlador supervisorio dentro del SHGE. La funcion es satisfacer el o los objetivos de operacion del sistema. La filosofia de operacion del controlador supervisorio se definio a partir de la configuracion electrica propuesta y de los objetivos de operacion del sistema. Por lo que respecta al desarrollo del controlador supervisorio, se llevo a cabo una revision de los controladores supervisorios actuales que utilizan alguna tecnica de control inteligente. A partir de

  3. Fuzzy control for the operation of an electrical energy generation system based on standard fuel cells PEM; Control difuso para la operacion de un sistema de generacion de energia electrica basado en celdas de combustible tipo PEM

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez R, Miguel; Gutierrez A, Ruben [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Rodriguez P, Alejandro [Centro Nacional de Investigacion y Desarrollo Tecnologico (Cenidet), Cuernavaca, Morelos (Mexico)

    2005-07-01

    Fuel cells, as totally clean power plants, have many applications in the industry in general, in the transport system, in the electricity generation for domestic consumption and in the communication systems, among others. When developing new forms of generation with renewable energy sources, it must be considered that petroleum will stop in being an available power resource. The interest in the study of the fuel cells has been increased in the last years because it is considered a solution to the supply of distributed energy problem. Therefore, already exist research institutions that are developing work on this technology. A generation of electrical energy system based on fuel cells is a nonlinear system where the control of the variables of the process, such as the temperature of the system and the pressurization of the reactants, are an important aspect for its proper operation, since it influences in the water balance and therefore in the global efficiency of the system. [Spanish] Las celdas de combustible, como fuente de energia totalmente limpia, tienen muchas aplicaciones en la industria en general: en el sistema de transporte, en la generacion de electricidad para consumo domestico y en los sistemas de comunicacion, entre otros. Al desarrollar nuevas formas de generacion con fuentes de energia renovables, se debe considerar que el petroleo dejara de ser un recurso energetico disponible. El interes en el estudio de las celdas de combustible se ha incrementado en los ultimos anos debido a que se le considera una solucion al problema de abasto de energia distribuida. Por lo tanto, ya existen instituciones de investigacion que estan desarrollando trabajos sobre esta tecnologia. Un sistema de generacion de energia electrica basado en celdas de combustible es un sistema no lineal en donde el control de las variables del proceso, tales como la temperatura del sistema y la presurizacion de los reactantes, es un aspecto importante para su buen funcionamiento, ya que

  4. Radiation protection; Proteccion Radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Ures Pantazi, M [Universidad de la Republica, Facultad de Quimica (Uruguay)

    1994-12-31

    This work define procedures and controls about ionizing radiations. Between some definitions it found the following topics: radiation dose, risk, biological effects, international radioprotection bodies, workers exposure, accidental exposure, emergencies and radiation protection.

  5. Electric power saving potential due to domestic refrigerators replacement; Potencial de ahorro de energia electrica por el reemplazo de refrigeradores domesticos

    Energy Technology Data Exchange (ETDEWEB)

    Peralta Solorio, Jose Luis [Fideicomiso para el Ahorro de Energia Electrica (Mexico)]. E-mail: jose.peralta@cfe.gob.mx

    2006-04-15

    In Mexico the second most used electrical appliance is: refrigerator. Owing to its use, it would be a promising option for electric power saving. In Guadalajara, Reynosa and Tampico it was performed a study with the aim of launching a project to replace the old refrigerators with new ones which are more effective and less expensive. Since the refrigerators cost and the electrical invoicing saving, the electric appliance change is profitable. To expect with this replacement more than eight million of refrigerators manufactured before 1997 will be changed. [Spanish] El refrigerador es el segundo electrodomestico mas utilizado a nivel nacional, esto permite que debido a su uso sea una opcion prometedora para el ahorro de energia electrica. Se hizo un estudio en Guadalajara, Reynosa y Tampico con el fin de lanzar un proyecto para sustituir los refrigeradores viejos por unos nuevos que sean mas eficaces y menos costosos. Por el costo de los refrigeradores y el ahorro en la facturacion electrica, el cambio de electrodomestico es rentable, de esta manera se espera que los mas de ocho millones de refrigeradores fabricados antes de 1997 que existen en el pais sean cambiados.

  6. Energy saving in buildings through the elimination of typical problems; Ahorro de energia electrica en edificios a traves de la eliminacion de problemas tipicos

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Rivero, Alex G [Genertek, S. A. de C. V., Mexico, D. F. (Mexico)

    1994-12-31

    The enormous electric energy consumption in buildings represents an important area of saving opportunities. The design of installations without advanced technical illumination criteria, the absence of standardization over energy efficiency, the lack of observation of the existing standards and guides, the continuous load growth in existing installations and the lack of appropriate maintenance, are some of the causes of the inefficient use of electric energy in buildings. Although the problems, and consequently the solutions, are exclusive for each unit, some of the former are frequently repeated. In this paper the problems found along more than 40 audits conducted in large buildings of different types in Mexico city are commented. [Espanol] El enorme consumo de energia electrica en edificios representa una importante area de oportunidad para ahorro. El diseno de instalaciones sin criterios luminotecnicos avanzados, la ausencia de normalizacion sobre eficiencia energetica, la falta de observancia de las normas y recomendaciones vigentes, el continuo crecimiento de carga en instalaciones existentes y la falta de mantenimiento adecuado son algunas de las causas del uso ineficiente de la energia electrica en inmuebles. Aunque los problemas y por tanto las soluciones son particulares para cada unidad, algunos de los primeros se repiten frecuentemente. En este trabajo se comentan los problemas encontrados a lo largo de mas de 40 auditorias realizadas a inmuebles grandes de diversos tipos en la ciudad de Mexico.

  7. Strategies to optimize the electric energy use in non-residential buildings; Estrategias para eficientizar el uso de la energia electrica en edificios no residenciales

    Energy Technology Data Exchange (ETDEWEB)

    Castro Flores, J.; Morillon Galvez, D. [Comision Nacional para el Ahorro de Energia, Mexico, D. F. (Mexico)

    1995-12-31

    This paper presents the problems identified in non-residential buildings, where the inadequate use of energy is mainly shown in three points: inadequate technology and maintenance, wrong use and wrong habits in the energy use. The consequences of this situation in the ecological, politic and social environment were analyzed. In base of the problems detected the following strategies are proposed: An adequate project and design, retrofit, maintenance and users awareness for the rational energy use. The economic evaluation performed for the implementation of these strategies shows a significant saving potential of the electric power, with measures of null and low investment. [Espanol] Se presenta la problematica identificada en edificios no residenciales; donde el uso inadecuado de la energia electrica se manifiesta principalmente en tres puntos: tecnologia y mantenimiento inadecuados, y mal uso y costumbres de la energia. Se analizo las consecuencias de esta situacion en el ambito ecologico, economico, politico y social. Con base a la problematica se proponen las siguientes estrategias: un adecuado proyecto y diseno, retrofit, mantenimiento y concientizacion del usuario para el uso racional de la energia. La evaluacion economica realizada para implantar estas estrategias muestra un significativo potencial de ahorro de energia electrica, con medidas de nula y baja inversion.

  8. Strategies to optimize the electric energy use in non-residential buildings; Estrategias para eficientizar el uso de la energia electrica en edificios no residenciales

    Energy Technology Data Exchange (ETDEWEB)

    Castro Flores, J; Morillon Galvez, D [Comision Nacional para el Ahorro de Energia, Mexico, D. F. (Mexico)

    1996-12-31

    This paper presents the problems identified in non-residential buildings, where the inadequate use of energy is mainly shown in three points: inadequate technology and maintenance, wrong use and wrong habits in the energy use. The consequences of this situation in the ecological, politic and social environment were analyzed. In base of the problems detected the following strategies are proposed: An adequate project and design, retrofit, maintenance and users awareness for the rational energy use. The economic evaluation performed for the implementation of these strategies shows a significant saving potential of the electric power, with measures of null and low investment. [Espanol] Se presenta la problematica identificada en edificios no residenciales; donde el uso inadecuado de la energia electrica se manifiesta principalmente en tres puntos: tecnologia y mantenimiento inadecuados, y mal uso y costumbres de la energia. Se analizo las consecuencias de esta situacion en el ambito ecologico, economico, politico y social. Con base a la problematica se proponen las siguientes estrategias: un adecuado proyecto y diseno, retrofit, mantenimiento y concientizacion del usuario para el uso racional de la energia. La evaluacion economica realizada para implantar estas estrategias muestra un significativo potencial de ahorro de energia electrica, con medidas de nula y baja inversion.

  9. Energy saving in buildings through the elimination of typical problems; Ahorro de energia electrica en edificios a traves de la eliminacion de problemas tipicos

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Rivero, Alex G. [Genertek, S. A. de C. V., Mexico, D. F. (Mexico)

    1993-12-31

    The enormous electric energy consumption in buildings represents an important area of saving opportunities. The design of installations without advanced technical illumination criteria, the absence of standardization over energy efficiency, the lack of observation of the existing standards and guides, the continuous load growth in existing installations and the lack of appropriate maintenance, are some of the causes of the inefficient use of electric energy in buildings. Although the problems, and consequently the solutions, are exclusive for each unit, some of the former are frequently repeated. In this paper the problems found along more than 40 audits conducted in large buildings of different types in Mexico city are commented. [Espanol] El enorme consumo de energia electrica en edificios representa una importante area de oportunidad para ahorro. El diseno de instalaciones sin criterios luminotecnicos avanzados, la ausencia de normalizacion sobre eficiencia energetica, la falta de observancia de las normas y recomendaciones vigentes, el continuo crecimiento de carga en instalaciones existentes y la falta de mantenimiento adecuado son algunas de las causas del uso ineficiente de la energia electrica en inmuebles. Aunque los problemas y por tanto las soluciones son particulares para cada unidad, algunos de los primeros se repiten frecuentemente. En este trabajo se comentan los problemas encontrados a lo largo de mas de 40 auditorias realizadas a inmuebles grandes de diversos tipos en la ciudad de Mexico.

  10. Results of the Service of External Dosimetry of the Centro de Proteccion e Higiene de las Radiaciones (CPHR), Cuba during the biennium 2010 - 2011

    International Nuclear Information System (INIS)

    Molina Perez, Daniel; Verdecia Sanchez, Maribel; Castro Soler, Ailza; Farrada Neyra, Yamilia

    2013-01-01

    The Service of Personal Dosimetry of the External Dosimetry Laboratory of the Centro de Proteccion y Higiene de las Radiaciones - CPHR of Cuba works with an automatic RADOS TLD system and includes the surveillance of the doses of whole body and extremities for photon radiation. The work presents the results of the service in the period 2010-2011, showing data related to the number and distribution of workers monitored for areas. The levels of occupational exposure area analyzed using various indicators such as: annual average dose for areas, number of workers who receive annual doses greater than zero, distribution of workers by dose intervals, and others. These indicators are compared with previous periods and with the values published by the UNSCEAR. In general, the average annual dose for all areas was less than 1 mSv for whole body and 3 mSv for hands. The number of exposed workers experienced significant variation from one year to another, considerably decreasing from 60% to 12% of the total. The work presents an analysis of this behavior and highlights that the country guarantees the personal dosimetry to 100% of exposed workers and that the results of the occupational exposure are within the established requirements

  11. Estudios de coordinación de las protecciones eléctricas por métodos computarizados aplicados a la central térmica enrique garcía

    OpenAIRE

    Yepez Perez, Juan Eduardo; Vasquez Lemus, José Dennys; Saavedra Mera, Juan

    2013-01-01

    Este proyecto está enfocado al estudio de los Equipos de Protección que se encuentran presente en el sistema de potencia de la Central Térmica Enrique García. Para ello, fue necesario realizar estudios de Flujo de Carga y Cortocircuito; con estos análisis determinaremos factores importantes a considerar al momento de realizar los ajustes de los relés de protecciones, ya que se debe conocer contra que anomalía, falla o disturbio se está protegiendo el equipo de Generación y Transformación de n...

  12. Formation of electrical islands conformed by a generator, a part from an electrical distributor and industrial plants; Formacion de islas electricas conformadas por un generador, parte de una distribuidora electrica y plantas industriales

    Energy Technology Data Exchange (ETDEWEB)

    Aguero, J.L.; Beroqui, M.; Barbieri, B. [Universidad Nacional de La Plata, Buenos Aires (Argentina). Facultad de Ingenieria. Instituto de Investigaciones Tecnologicas para Redes y Equipos Electricos

    2001-07-01

    The goal of this paper is to describe, through an example, the aspects of importance to be taken into consideration for a successful electric island formation in cases that have an important generation excess with respect to the demand, and in cases that result in a balanced condition.This paper is based on the accomplished investigations due to the need of a petrochemistry industry of increasing the reliability of its electric power provision.

  13. Electrical energy saving in motors and frequency variators; Ahorro de energia electrica en motores y variadores de frecuencia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Neri, Roger [Comision Federal de Electricidad (CFE) (Mexico)

    2005-07-01

    The necessity of saving energy is urgent and undeniable. We must already begin with the rational use of energy. Which is obtaining the maximum benefit of the consumed energy and of the necessary facilities for its generation, transmission and use. Guaranteeing at the same time an operation free of interferences or interruptions for the users. The electricity in alternating current does not allow its storage, reason why it is necessary to generate and distribute it at the precise moment when it is required. This forces to determine the proportions of the generation facilities, to be able to feed the periods of maximum demand called {sup p}eaks{sup .} It is this very point where the problem of the inappropriate use of the electrical energy starts. The energy waste is self-evident during the periods of low demand because of the low efficiency of the sub-utilized facilities. Electrical motors of the induction type use approximately more than 60% of the energy in the industry. If we use high efficiency motors instead of standard motors, a better advantage of the energy demanded from Comision Federal de Electricidad (CFE) is obtained. [Spanish] Es impostergable e innegable la necesidad de ahorrar energia. Tenemos que empezar ya con el uso racional de la energia: Obtener el maximo beneficio de la energia consumida y de las instalaciones necesarias para su generacion, transmision y utilizacion. Garantizando a los usuarios un funcionamiento sin interferencias o interrupciones. La electricidad en corriente alterna no permite su almacenamiento, por lo que es necesario generarla y distribuirla en el momento preciso en que es requerida. Esto obliga a dimensionar las instalaciones de generacion, para poder alimentar los periodos de maxima demanda llamados pico. Desde esta parte inicia el problema de la mala utilizacion de la energia electrica. Ya que en los periodos de baja demanda, las instalaciones se encuentran subutilizadas y si su eficiencia es muy baja, el desperdicio de

  14. Control voltage of the generator of auto-excited induction for applications on micro/mini generation o electric power; Control de voltaje del generador de induccion auto-excitado para aplicaciones de micro/mini generacion de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Torres Montalvo, Emmanuel

    2006-09-15

    Although only one part of the mini/micro hydraulic power has been exploited in our country, this type of electric energy generation can be considered as a visible way of electricity generation, mainly related to the ecological, economical and social aspects. The impact that these power plants can have in the regions in which they are installed is always positive: cost energy cost reduction, economical spills and mainly a social welfare. The electric energy is one of the pillars for the economical development of a country and provides a better life quality. Nowadays the research and the technology oriented to the operation and control of the micro/mini power plants has awaken the interest of many researchers in several countries of the world as China, India, Canada, and USA to mention some of them. The induction generator plays a crucial role in the uses of these technologies. The work of Basset and Potter in 1935 is the angular stone over the possibility of generating energy making use of the induction machine and a capacitors bank connected to the machine terminals. This configuration is known as induction auto-excited generator (GIAE). Several investigations have been realized that deal about the functioning principle and the dynamic behavior a GIAE, which can supply electric power in remote isolated regions. In the existing literature have been proposed control strategies to offer voltage regulations and/or frequency into the acceptable range. Some of these control strategies present problems such a demand of a reactive power, harmonics injections in the system, the control circuits are complicated, expensive and voluminous and prone to fail. This paper realizes an analysis of the necessary and sufficient conditions so that an induction machine can operate as GIAE. The corresponding curves are presented for each studied case. The dynamic behavior of the voltage and the frequency generated by the GIAE are studied in detail, which is a contribution to the existing

  15. Estimated saving potential and efficient use of energy in air conditioning by means of the solar protection; Potencial estimado de ahorro y uso eficiente de energia en aires acondicionados mediante la proteccion solar

    Energy Technology Data Exchange (ETDEWEB)

    Mejia D, David; Morillon G, David; Rodriguez V, Luis [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2001-07-01

    In here it is presented the analysis of the impact of the solar gains through the transparent parts of a prototype house of social interest, located in a dry warm climate. This analysis was made to determine the gains through windows for the summer time and under the following conditions: without outside solar protections, with the use of eaves, solar breakers and finally with the use of both systems of solar protection. The results were compared to obtain the considered potential of energy saving in cooling equipment, that could be obtained in future houses to build. [Spanish] Se presenta el analisis del impacto de las ganancias solares a traves de las partes transparentes de un prototipo de vivienda de interes social, ubicado en un clima calido seco. Dicho analisis se realizo para determinar las ganancias a traves de ventanas para la epoca de verano y bajo las siguientes condiciones: sin protecciones solares exteriores, con el empleo de aleros, con quiebrasoles y finalmente con el empleo de ambos sistemas de proteccion solar. Se compararon los resultados para obtener el potencial estimado de ahorro de energia en equipo de enfriamiento, que se tendria en las futuras viviendas por construir.

  16. Planning the expansion of electrical transmission networks with evolutionary programming; Planeacion de la expansion de redes de transmision electrica con programacion evolucionaria

    Energy Technology Data Exchange (ETDEWEB)

    Ceciliano Meza, Jose Luis

    1997-12-31

    In this work it is presented for the first time in the literature the solution of the problem of the planning the expansion of an electrical transmission network (PERTE) with the use of the Evolutionary Programming. The evolutionary programming is a stochastic method of optimization with similar characteristics to the generic algorithms, but different. During the development of this work it is shown what each one of these two heuristic methods of optimization consist of. Additionally, the main characteristics of other two heuristic methods known in the literature are described (Tabu Searching and Simulated Annealing). These two methods together with the genetic algorithms and decomposition of Benders have also been used to solve the problem of planning PERTE. The operation of the proposed algorithm of evolutionary programming was tested in two networks of electrical transmission. The first case of test is a system which is known in the literature. The second case is a representative system of the electrical transmission network of Central America. The results obtained improve all the results shown when applying different heuristic methods of optimization (genetic algorithms, simulated annealing and Tabu searching) to solve the same problem. [Espanol] En este trabajo se presenta por primera vez en la literatura, la solucion del problema de la planeacion de expansion de una red de transmision electrica (PERTE) con el uso de la Programacion Evolucionaria. La programacion evolucionaria es un metodo estocastico de optimizacion con caracteristicas similares a los algoritmos geneticos, pero diferente. Durante el desarrollo de este trabajo se muestra en que consiste cada uno de estos dos metodos heuristicos de optimizacion. Ademas, se describen las caracteristicas principales de otros dos metodos heuristicos conocidos en la literatura (busqueda Tabu y Recorrido Simulado). Estos dos metodos juntos con los algoritmos geneticos y descomposicion de Benders tambien han sido

  17. Magnetic losses and reactance change by the use of metallic conduit in electrical installations; Perdidas magneticas y cambio de reactancia por la tuberia metalica en instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Campero Littlewood, Eduardo; Castaneda D, Miguel; Castulo A, Roberto; Bratu Serban, Neagu [Universidad Autonoma Metropolitana-Azcapotzalco, Mexico, D. F. (Mexico)

    1996-12-31

    In this paper are presented the results obtained in the measurement of magnetic losses in metallic conduits in electric installations. The losses for parasitic currents and by hysteresis were obtained in different conditions of magnetic density, caused by the net current resulting from the sum of all the currents of all the conductors that travel along the conduit. These currents are named differential currents, and the conditions in which they appear in the electric installations are described. The magnetic induction phenomenon that occurs in metallic conduit is briefly described and the basic concepts that describe it. A theoretical-experimental methodology is offered to quantify the energy losses by parasitic currents and by the metal magnetization in these metallic conduits. At the same time, the impact of these differential currents impact in the reactance of the electric installation is quantified. The obtained results for twelve conduits of different diameters and different wall thickness are shown. A comparison analysis is made with the reported results in a previous article, where the losses were estimated by means of the temperature rise measurement of the metallic wall. [Espanol] En este articulo se presentan los resultados obtenidos en la medicion de perdidas magneticas en tuberias conduit (metalicas) en instalaciones electricas. Las perdidas por corrientes parasitas y por histeresis se obtuvieron para diferentes condiciones de densidad magnetica, provocada por la corriente neta resultante de la suma de las corrientes de todos los conductores que viajan por la tuberia. A estas corrientes se les designa corrientes diferenciales y se describen las condiciones en las que estas aparecen en las instalaciones electricas. Se explica brevemente el fenomeno de induccion magnetica que se presenta en las tuberias metalicas y los conceptos basicos que la describen. Se plantea una metodologia teorico-experiemental para cuantificar las perdidas de energia, por

  18. Magnetic losses and reactance change by the use of metallic conduit in electrical installations; Perdidas magneticas y cambio de reactancia por la tuberia metalica en instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Campero Littlewood, Eduardo; Castaneda D, Miguel; Castulo A, Roberto; Bratu Serban, Neagu [Universidad Autonoma Metropolitana-Azcapotzalco, Mexico, D. F. (Mexico)

    1997-12-31

    In this paper are presented the results obtained in the measurement of magnetic losses in metallic conduits in electric installations. The losses for parasitic currents and by hysteresis were obtained in different conditions of magnetic density, caused by the net current resulting from the sum of all the currents of all the conductors that travel along the conduit. These currents are named differential currents, and the conditions in which they appear in the electric installations are described. The magnetic induction phenomenon that occurs in metallic conduit is briefly described and the basic concepts that describe it. A theoretical-experimental methodology is offered to quantify the energy losses by parasitic currents and by the metal magnetization in these metallic conduits. At the same time, the impact of these differential currents impact in the reactance of the electric installation is quantified. The obtained results for twelve conduits of different diameters and different wall thickness are shown. A comparison analysis is made with the reported results in a previous article, where the losses were estimated by means of the temperature rise measurement of the metallic wall. [Espanol] En este articulo se presentan los resultados obtenidos en la medicion de perdidas magneticas en tuberias conduit (metalicas) en instalaciones electricas. Las perdidas por corrientes parasitas y por histeresis se obtuvieron para diferentes condiciones de densidad magnetica, provocada por la corriente neta resultante de la suma de las corrientes de todos los conductores que viajan por la tuberia. A estas corrientes se les designa corrientes diferenciales y se describen las condiciones en las que estas aparecen en las instalaciones electricas. Se explica brevemente el fenomeno de induccion magnetica que se presenta en las tuberias metalicas y los conceptos basicos que la describen. Se plantea una metodologia teorico-experiemental para cuantificar las perdidas de energia, por

  19. Questions to the radiological protection in the Universidad Nacional Autonoma de Mexico; Cuestionamientos a la proteccion radiologica en la Universidad Nacional Autonoma de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Salas M, B., E-mail: salasmarb@yahoo.com.mx [UNAM, Facultad de Ciencias, Departamento de Fisica, Circuito exterior s/n, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2014-08-15

    In the Physics Department of the Sciences Faculty of the Universidad Nacional Autonoma de Mexico (UNAM) exist at least 3 sites where radioactive sources and generating equipment s of ionizing radiation are managed: The Modern Physics Laboratory, the Radiological Analysis of Environmental Samples Workshop and the Collisions Workshop; the first of them has two neutron sources, in addition to other emitted sources of gamma and beta radiation. The neutron sources are of Americium 241-Beryllium and other of Californium-252 which have been operated outside of the control of the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) that is the regulator organ in Mexico in nuclear matter, because the Operation License No. 183/85, with file number 657 that protected them, lost their validity from August 13, 1987 (25 years behind), what motivated to that the CNSNS assured them. Later to the closing of the Radiological Analysis of Environmental Samples Workshop was believed that a Barium-133 source had been extracted in an illegal way; an investigation realized by the CNSNS determined that the radioactive source was always inside of the detection systems and radiation measurement, for what this source was never lost. In the Collisions Workshop operated an Experimental Accelerator of Particles that the CNSNS prohibited its operation for not having the corresponding license. These examples can be considered as bad practices of radiological protection that should be pointed out to eradicate their promotion and to avoid this way the exposure to the radiation of the occupational exposed personnel and people in general, being also avoided dose of unnecessary radiation. The Instituto Federal de Acceso a la Informacion Publica y Proteccion de Datos (IFAI) in Mexico was a key factor to obtain the information that allowed the realization of this work that was carried out in the Sciences Faculty of the UNAM. (Author)

  20. Electric energy saving and its impact in the mining industry; El ahorro de energia electrica y su impacto en la industria minera

    Energy Technology Data Exchange (ETDEWEB)

    Urteaga Dufour, Jose Antonio [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1994-12-31

    In this paper are shown the most important results of the energy diagnosis performed in some representative industries of the mining industry, where opportunity areas were detected in electric energy saving, starting from those measures that do not require investment up to the ones that require medium investment, recoverable in less than two years terms as a maximum and with electric energy saving ranging from 10% to 25%. [Espanol] En este trabajo, se presentan los resultados mas importantes, obtenidos en el diagnostico energetico realizado en algunas empresas representativas de la rama de la mineria, en donde se detectaron areas de oportunidad de ahorro de energia electrica que van desde aquellas medidas que no requieren inversiones hasta las que requieren medianas inversiones, recuperables en menos de dos anos como maximo y con ahorros de energia que van desde un 10% hasta un 25%.

  1. System for the reliability analysis of the electric energy supply; Sistema para el analisis de confiabilidad del suministro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Perales, Favio; Martinez, Javier; Huesca, Francisco; Garcia, Norma; Nieva, Rolando [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    A computer tool, developed for the reliability evaluation of the electric energy supply, considering the faults in the generation and transmission systems, is presented. The application of the tool in planning the expansion and operation of the electric systems, the methodology of the solution employed and the various functions it accounts for, are described. At the end some illustrative examples of its applications by means of the studies with a model of representative characteristics of the interconnected national system. [Espanol] Se presenta una herramienta computacional desarrollada para evaluar la confiabilidad del suministro de energia electrica, considerando las fallas en los sistemas de generacion y transmision. Se describen las aplicaciones de la herramienta en la planeacion de la expansion y de la operacion de sistemas electricos, la metodologia de solucion empleada y las diversas funciones con que cuenta. Al final se presentan algunos ejemplos ilustrativos de sus aplicaciones mediante estudios con un modelo de caracteristicas representativas del sistema interconectado nacional.

  2. System for the reliability analysis of the electric energy supply; Sistema para el analisis de confiabilidad del suministro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Perales, Favio; Martinez, Javier; Huesca, Francisco; Garcia, Norma; Nieva, Rolando [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    A computer tool, developed for the reliability evaluation of the electric energy supply, considering the faults in the generation and transmission systems, is presented. The application of the tool in planning the expansion and operation of the electric systems, the methodology of the solution employed and the various functions it accounts for, are described. At the end some illustrative examples of its applications by means of the studies with a model of representative characteristics of the interconnected national system. [Espanol] Se presenta una herramienta computacional desarrollada para evaluar la confiabilidad del suministro de energia electrica, considerando las fallas en los sistemas de generacion y transmision. Se describen las aplicaciones de la herramienta en la planeacion de la expansion y de la operacion de sistemas electricos, la metodologia de solucion empleada y las diversas funciones con que cuenta. Al final se presentan algunos ejemplos ilustrativos de sus aplicaciones mediante estudios con un modelo de caracteristicas representativas del sistema interconectado nacional.

  3. Electric energy saving and its impact in the mining industry; El ahorro de energia electrica y su impacto en la industria minera

    Energy Technology Data Exchange (ETDEWEB)

    Urteaga Dufour, Jose Antonio [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1993-12-31

    In this paper are shown the most important results of the energy diagnosis performed in some representative industries of the mining industry, where opportunity areas were detected in electric energy saving, starting from those measures that do not require investment up to the ones that require medium investment, recoverable in less than two years terms as a maximum and with electric energy saving ranging from 10% to 25%. [Espanol] En este trabajo, se presentan los resultados mas importantes, obtenidos en el diagnostico energetico realizado en algunas empresas representativas de la rama de la mineria, en donde se detectaron areas de oportunidad de ahorro de energia electrica que van desde aquellas medidas que no requieren inversiones hasta las que requieren medianas inversiones, recuperables en menos de dos anos como maximo y con ahorros de energia que van desde un 10% hasta un 25%.

  4. A simple and efficient formula for saving electric energy in lighting systems; Una formula sencilla y eficaz para ahorrar energia electrica en sistemas de iluminacion

    Energy Technology Data Exchange (ETDEWEB)

    Figueroa Noriega, L. R. [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico, Mexico, D. F. (Mexico)

    1995-12-31

    In the Metropolitan Area of Mexico City, as well as in other regions with a similar climate, there are an important number of users of the electric energy service, whose main load consists of lighting, since systems such as environmental conditioning, refrigeration, pumping and others are either not necessary or lack of importance as electric energy consumers. These are classified in the range of small users that altogether represent a significant saving, but the precarious diffusion of the technological advances have not contemplated the need of carrying on corrective actions. Among these users are the offices, sites of entertainment and a range of commerces and services such as clothing stores, pharmacies, shoe stores, printing shops, dry cleaner`s, restaurants, barber shops, etc. The present paper pretends to provide a simple methodology easy to carry on, derived form a demonstrative project that FIDE (Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico) successfully carried out for the Club Deportivo Berinbau. [Espanol] En el area Metropolitana de la ciudad de Mexico, asi como en otras regiones con clima similar, existe un numero importante de usuarios del servicio de energia electrica cuya carga principal consiste en iluminacion, ya que sistemas como acondicionamiento ambiental, refrigeracion, bombeo y otros, o bien no son necesarios o carecen de la importancia en cuanto a consumo de energia electrica. Estos se catalogan dentro del rango de pequenos usuarios que en conjunto representan un potencial de ahorro significativo pero que, debido a la precaria difusion de los adelantos tecnologicos, no han contemplado la posibilidad de llevar a cabo acciones correctivas. Entre estos usuarios se encuentran oficinas, lugares de esparcimiento, planteles educativos y una gama de comercios y servicios como tiendas de ropa, farmacias, zapaterias, imprentas, tintorerias, restaurantes, peluquerias, etc. El presente trabajo pretende proporcionarles una

  5. A simple and efficient formula for saving electric energy in lighting systems; Una formula sencilla y eficaz para ahorrar energia electrica en sistemas de iluminacion

    Energy Technology Data Exchange (ETDEWEB)

    Figueroa Noriega, L R [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico, Mexico, D. F. (Mexico)

    1996-12-31

    In the Metropolitan Area of Mexico City, as well as in other regions with a similar climate, there are an important number of users of the electric energy service, whose main load consists of lighting, since systems such as environmental conditioning, refrigeration, pumping and others are either not necessary or lack of importance as electric energy consumers. These are classified in the range of small users that altogether represent a significant saving, but the precarious diffusion of the technological advances have not contemplated the need of carrying on corrective actions. Among these users are the offices, sites of entertainment and a range of commerces and services such as clothing stores, pharmacies, shoe stores, printing shops, dry cleaner`s, restaurants, barber shops, etc. The present paper pretends to provide a simple methodology easy to carry on, derived form a demonstrative project that FIDE (Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico) successfully carried out for the Club Deportivo Berinbau. [Espanol] En el area Metropolitana de la ciudad de Mexico, asi como en otras regiones con clima similar, existe un numero importante de usuarios del servicio de energia electrica cuya carga principal consiste en iluminacion, ya que sistemas como acondicionamiento ambiental, refrigeracion, bombeo y otros, o bien no son necesarios o carecen de la importancia en cuanto a consumo de energia electrica. Estos se catalogan dentro del rango de pequenos usuarios que en conjunto representan un potencial de ahorro significativo pero que, debido a la precaria difusion de los adelantos tecnologicos, no han contemplado la posibilidad de llevar a cabo acciones correctivas. Entre estos usuarios se encuentran oficinas, lugares de esparcimiento, planteles educativos y una gama de comercios y servicios como tiendas de ropa, farmacias, zapaterias, imprentas, tintorerias, restaurantes, peluquerias, etc. El presente trabajo pretende proporcionarles una

  6. The distribution of the electric energy consumed in the World Trade Center building; La distribucion de la energia electrica consumida en el edificio World Trade Center

    Energy Technology Data Exchange (ETDEWEB)

    Gaona de la Fuente, Alvaro; Carrillo Borja, Angel [Luz y Fuerza del Centro, Mexico, D. F. (Mexico)

    1997-12-31

    This document describes the distribution of the electric energy in the World Trade Center building. Also called the Business International Capital, it is a modern international concept that integrates under the same roof services and supports required by the foreign commerce, with a great 50 stories high building, information network, a business center, a commercial center, an international center for exhibits and conventions and a luxury hotel. It is a modern building equipped with a numberless technological advancements an a total installed electrical load of 35000 kVA. The distribution structures utilized for high buildings are described, the structure that was decided to adopt in the World Trade Center, the requirement for the execution of the distribution electric work, the Luz y Fuerza installations in the buildings conglomerate, the operation and maintenance of the distribution network of this building and the basic needs for new installations of this type of buildings [Espanol] En el presente documento se describe la distribucion de la energia electrica del edificio World Trade Center de la ciudad de Mexico. Llamado tambien la capital internacional de los negocios es un moderno concepto internacional que integra bajo un mismo techo servicios y apoyos que se requieren para el comercio exterior contando con una gran torre de 50 pisos, red de informacion, un centro de negocios, un centro comercial, un centro internacional de exposiciones y convenciones y un hotel de lujo. Es un edificio moderno equipado con un sinnumero de adelantos tecnologicos y con una carga total instalada de 35000 kVA. Se describen las estructuras de distribucion utilizadas en edificios altos, la estructura que se decidio implantar en el World Trade Center, los requerimientos para la ejecucion de la obra electrica de distribucion, las instalaciones de Luz y Fuerza en el conjunto de dicho edificio, la operacion y mantenimiento de la red de distribucion de este edificio, y las necesidades

  7. A microwave technique for electrical conductivity measurements in semiconductors; Un procedimiento en frecuencia de microondas para la medicion de la conductividad electrica en semiconductores

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, A; Zehe, A [Benemerita Universidad Autonoma de Puebla, Puebla (Mexico); Starostenko, O [Universidad de las Americas, Puebla, (Mexico); Perez, L [Benemerita Universidad Autonoma de Puebla, Puebla (Mexico)

    2003-01-15

    In the present paper a theoretical approach is given together with the description of the experimental technique for electrical conductivity measurements of semiconductors in frequency range of 10 GHz, corresponding to a wavelength of {lambda}= 3 cm. It is shown, that the sample conductivity, measured without the need of electrical contacts, Is practically identical with results obtained by direct current methods. The potential use of the method for dielectric measurements in samples of general shape is included in the discussion. Given that the local electrical field is known only in bodies of ellipsoidal shape, one has to apply approximation methods for sample shapes of practical relevance (cylinders, cubes, disks). Finally, the measuring range and corresponding errors are explained on the base of measurements realized with silicon samples. [Spanish] En el presente trabajo se desarrolla la teoria junto con la descripcion del arreglo experimental para la medicion de la conductividad electrica en muestras semiconductoras, utilizando un campo de microondas de {lambda}= 3 cm, correspondiente a una frecuencia n de 10 GHz. Se demuestra que la conductividad electrica medida sin la necesidad de contactos electricos es practicamente identica con resultados obtenidos por el metodo comun utilizando corriente directa (d.c.). Se incorpora en la discusion ademas el potencial del metodo para el estudio de propiedades dielectricas en muestras de geometria general. Dado que solamente en cuerpos con geometria elipsoidal se conoce bien el campo electrico local, y con esto el momento bipolar inducido, para muestras de geometrias mas practicas (cilindros, cubos, discos) se acude a metodos de aproximacion. Finalmente, se discute el rango de mediciones y errores, y se presentan mediciones concretas, utilizando muestras de silicio.

  8. Introduction criteria and concepts on energy saving in the technical standards for electric installations; Introduccion de criterios y conceptos de ahorro de energia en las normas tecnicas para instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Rincon Nader, Jorge A [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1993-12-31

    The project Introduction Criteria and Concepts on Energy Saving in the Technical Standards for electric installations, is described, whose immediate objective is to recommend and in some cases regulate the use of energy saving equipment and devices and the adoption of attitudes and procedures that convey into saving, and the rational and efficient use of the electric energy. [Espanol] Se describe el proyecto Introduccion de Criterios y Conceptos de Ahorro de Energia en las Normas Tecnicas para instalaciones electricas, que tiene como objetivo inmediato recomendar, y en algunos casos reglamentar el uso de equipos y dispositivos ahorradores y la adopcion de actitudes y procedimientos que conduzcan a un ahorro y uso racional y eficiente de la energia electrica.

  9. Introduction criteria and concepts on energy saving in the technical standards for electric installations; Introduccion de criterios y conceptos de ahorro de energia en las normas tecnicas para instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Rincon Nader, Jorge A. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1992-12-31

    The project Introduction Criteria and Concepts on Energy Saving in the Technical Standards for electric installations, is described, whose immediate objective is to recommend and in some cases regulate the use of energy saving equipment and devices and the adoption of attitudes and procedures that convey into saving, and the rational and efficient use of the electric energy. [Espanol] Se describe el proyecto Introduccion de Criterios y Conceptos de Ahorro de Energia en las Normas Tecnicas para instalaciones electricas, que tiene como objetivo inmediato recomendar, y en algunos casos reglamentar el uso de equipos y dispositivos ahorradores y la adopcion de actitudes y procedimientos que conduzcan a un ahorro y uso racional y eficiente de la energia electrica.

  10. RETOS A LAS PROTECCIONES ELÉCTRICAS EN LAS REDES DE DISTRIBUCIÓN CON GENERACIÓN DISTRIBUIDA CHALLENGES OF DISTRIBUTED GENERATION ON THE ELECTRIC PROTECTION IN DISTRIBUTION NETWORKS

    Directory of Open Access Journals (Sweden)

    Marta Bravo de las Casas

    2009-04-01

    Full Text Available Las redes de distribución han sido diseñadas para que la potencia fluya en una sola dirección. La introducción de la Generación Distribuida (GD hace que esta consideración ya no sea válida. Esto traerá nuevos retos para la operación y el diseño de la red. Una de las áreas críticas más afectadas que existe es la de las protecciones eléctricas. En este trabajo se hace el estudio de cómo se afectan los ajustes de las protecciones eléctricas al trabajar con generación distribuida en una red de distribución. Para ello se simuló una red con la ayuda del software denominado PSX. Se conectó generación en distintos lugares, de diferentes capacidades y tipos. Se calcularon los niveles de cortocircuitos en los distintos escenarios para los cuales fueron ajustadas las protecciones. Se obtuvieron un conjunto de resultados interesantes, los cuales pueden conducir a nuevas estrategias en lo que respecta a estos equipos.The distribution networks have been designed so that the power flows in a single direction. When the Distributed Generation is introduced this consideration is no longer valid. Distributed Generation will bring new challenges for the operation and the design of the network. One of the most critical areas affected is the electric protection. This paper discusses issues of how the adjustments of the electric protection are affected when the Distributed Generation is introduced in a distribution network. For this purpose, the network was simulated with the help of the software named PSX. The generation was connected in different places, with different capacities and types. The levels of short circuits were calculated in the different scenarios in which the protections were adjusted. A set of interesting results was obtained, which can lead to new strategies in what concerns to these protections.

  11. Evaluation of the reliability of electric power transmission systems; Evaluacion de confiabilidad de sistemas de transmision de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Vega Ortiz, Miguel

    1989-07-01

    algorithm in a digital program, this was proved in a personal computer applying it to IEEE transmission systems evaluated with other methods, among them one of 140 buses and 199 transmission lines. The results as far as reliability indexes compared with the other methods were very satisfactory and promising as far as required CPU time and memory for larger systems. [Spanish] En esta tesis se ataca el problema de la Evaluacion de la Confiabilidad de los Sistemas de Transmision de Energia Electrica para fines de su planeacion integral. Una vez descrito el problema se presentan los indices que miden la confiabilidad de los sistemas electricos de potencia. Despues se describen los metodos para evaluar las redes de transmision, como el de Enumeracion de Contingencias, el Monte Carlo, el de Markov y los metodos para sistemas complejos como el de Cortes Minimos. Este ultimo se desarrolla ampliamente por las ventajas que presenta su aplicacion en la planeacion de redes grandes y complejas. El metodo de cortes minimos consta de dos grandes pasos: Determinar los cortes minimos para los puntos de carga y calcular los indices de confiabilidad en base a los cortes minimos. Los algoritmos convencionales para la determinacion de cortes minimos consideran un problema por cada punto de carga en forma independiente pasando por una determinacion de caminos minimos. En este tipo de algoritmos el tiempo de CPU y el espacio en memoria requeridos crecen exponencialmente para el caso de sistemas de transmision grandes, lo que representa una fuerte restriccion para su aplicacion. Para resolver este problema se establecio una metodologia en la que se modela el sistema por medio de un grafo y se determinan los cortes minimos con un algoritmo basado en la construccion de ciclos en el grafo dual. Con estos cortes se evalua la conexidad y capacidad de la red, obteniendose los indices de confiabilidad para cada bus y para el sistema. Estos indices se calculan con la representacion equivalente para

  12. Advance of the National Program of Radiological Protection and Safety for medical diagnostic with X-rays; Avance del Programa Nacional de Proteccion y Seguridad Radiologica para diagnostico medico con rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Verdejo S, M. [Direccion de Riesgos Radiologicos, Direccion General de Salud Ambiental (Mexico)

    1999-07-01

    The National Program of Radiological Protection and Safety for medical diagnostic with X-ray (Programa Nacional de Proteccion y Seguridad Radiologica para diagnostico medico con rayos X) was initiated in the General Direction of Environmental Health (Direccion General de Salud Ambiental) in 1995. Task coordinated with different dependences of the Public Sector in collaboration between the Secretary of Health (Secretaria de Salud), the National Commission of Nuclear Safety and Safeguards (Comision Nacional de Seguridad Nuclear y Salvaguardias) and, the National Institute of Nuclear Research (Instituto Nacional de Investigaciones Nucleares). The surveillance to the fulfilment of the standardization in matter of Radiological Protection and Safety in the medical diagnostic with X-rays has been obtained for an important advance in the Public sector and it has been arousing interest in the Private sector. (Author)

  13. Design and implementation of the 40, 50/51 protections and MEL, OEL and V/HZ limiters in a synchronous generator; Diseno e implementacion de las protecciones 40,50/51 y limitadores MEL, OEL y V/HZ en un generador sincrono

    Energy Technology Data Exchange (ETDEWEB)

    Goitia Ochoa, Salvador Hector

    2001-10-15

    The thesis shows the design and implementation of loss of field (40) and overcurrent (50/51) relays, minimum excitation limiter (MEL), over excitation limiter (OEL) and Voltage / Frequency limiter (V/Hz). It is also shown the development of a synchronous machine mathematical model for representing the conditions of open circuit, three phase short-circuit at stator terminals and short/open circuit at the field winding. Finally, a study about the magnetic saturation effect on the protection against loss of excitation is shown. It is studied the effects on the relay settings by using the X{sub d} saturated reactance. All the tests were applied for a salient-pole synchronous machine of 7 kVA, 220 V and 1800 rpm. The machine is at the Propulsion Laboratory of the Instituto Tecnologico de La Laguna. [Spanish] En este trabajo de tesis se realiza el diseno e implementacion de las protecciones contra la perdida de campo (40) y de sobrecorriente (50/51), asi como el de los limitadores de minima excitacion (MEL), maxima excitacion (OEL) y el limitador de Voltaje / Frecuencia (V/Hz). Ademas se muestra el desarrollo de las ecuaciones del modelo matematico del generador sincrono en condiciones de circuito abierto, con una falla trifasica en terminales, con el devanado de campo en corto circuito y en circuito abierto. Por ultimo se realiza un estudio en el cual se incluye el efecto de la saturacion magnetica en la proteccion contra la perdida de campo y las consecuencias que traeria el ajustar la proteccion usando el parametro de X{sub d} saturada. Las pruebas fisicas de las protecciones y limitadores fueron aplicadas a un generador sincrono de polos salientes con una capacidad de 7 kVA, 220 V, 1800 rpm, localizado en el Laboratorio de Propulsion de Instituto Tecnologico de la laguna.

  14. Weather impact on the electric energy consumption of domestic users; Impacto del clima en el consumo de energia electrica en los usuarios domesticos

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Niembro, Gaudencio; Fiscal Escalante, Raul [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    It is said that when an energy saving and efficient use of energy program is implemented it must be a business for three: the user, the society and the electric utility. In respect to the user, his decision making is quite simple: is it cheaper or more expensive for me?. Unfortunately in many cases we want a very short return time or the money needed for the initial investment is not available. For instance, and incandescent bulb is several times less expensive than a compact fluorescent lamp, but if we make the calculation on the life-time and on the power consumption reduction of the compact fluorescent lamp, we can conclude that this one is more economic. The benefit for the society can be seen under many different aspects, being the most important the natural resources conservation and the environment. From the stand point of the utility the heavier possible factors are the postponement of the investments and the system reliability. When some of the programs of the Demand Side Management (DSM) are applied, the utilities support or promote non financially profitable but improve their image before the user, on creating a consciousness in the saving and in the efficient use of energy: a short term investment is made and a long term revenue is obtained. For this reason for an optimum selection and implementation the saving and the efficient use of electric energy measures a detailed knowledge of the consumption way is required. In this paper the importance of monitoring the way the different type of users employ the energy in order to make up decisions on DSM programs in many different scenarios: cities, type of users, income level, etc. is shown. [Espanol] Se dice que cuando se implementa un programa de ahorro y uso eficiente de la energia electrica, debe ser negocio para tres: el usuario, la sociedad y la empresa electrica. En lo que respecta al usuario, su toma de decision es muy simple: me resulta mas barato o mas caro. Desafortunadamente en muchos de los casos

  15. Weather impact on the electric energy consumption of domestic users; Impacto del clima en el consumo de energia electrica en los usuarios domesticos

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Niembro, Gaudencio; Fiscal Escalante, Raul [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1999-12-31

    It is said that when an energy saving and efficient use of energy program is implemented it must be a business for three: the user, the society and the electric utility. In respect to the user, his decision making is quite simple: is it cheaper or more expensive for me?. Unfortunately in many cases we want a very short return time or the money needed for the initial investment is not available. For instance, and incandescent bulb is several times less expensive than a compact fluorescent lamp, but if we make the calculation on the life-time and on the power consumption reduction of the compact fluorescent lamp, we can conclude that this one is more economic. The benefit for the society can be seen under many different aspects, being the most important the natural resources conservation and the environment. From the stand point of the utility the heavier possible factors are the postponement of the investments and the system reliability. When some of the programs of the Demand Side Management (DSM) are applied, the utilities support or promote non financially profitable but improve their image before the user, on creating a consciousness in the saving and in the efficient use of energy: a short term investment is made and a long term revenue is obtained. For this reason for an optimum selection and implementation the saving and the efficient use of electric energy measures a detailed knowledge of the consumption way is required. In this paper the importance of monitoring the way the different type of users employ the energy in order to make up decisions on DSM programs in many different scenarios: cities, type of users, income level, etc. is shown. [Espanol] Se dice que cuando se implementa un programa de ahorro y uso eficiente de la energia electrica, debe ser negocio para tres: el usuario, la sociedad y la empresa electrica. En lo que respecta al usuario, su toma de decision es muy simple: me resulta mas barato o mas caro. Desafortunadamente en muchos de los casos

  16. Development and implementation of a pilot network for continuous monitoring of electric energy; Desarrollo e implantacion de una red piloto de monitoreo continuo de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Cifuentes, A.; Cortes Eslava, A. [Facultad de Ingenieria, UNAM, Mexico, D. F. (Mexico)

    1997-12-31

    The ``Programa Universitario de Energia (PUE)`` (University Energy Program) of the Universidad Nacional Autonoma de Mexico (UNAM) through the project ``Ecologic Control of The University Campus`` has the objective of instrumenting policies for the rational use of the electric energy in the UNAM installations. The PUE has performed a series of activities aimed at the establishment of an integral program for the electric energy management in the UNAM. This program has to consider the measures for energy saving (MES) of general kind and to promote a series of specific measures to be adequated and implemented for each one of the departments. The success in establishing a series of MES compels to quantify its effects, to register and to analyze them to be in position of enhancing them, since it must be kept in mind that something that can not be measured can not be improved. For this purpose the PUE is developing a continuous monitoring pilot network of electric energy with local and remote access and an automated metering system. Two monitoring schemes are experimented, one commercial metering equipment and another one with own metering technology. In this paper the characteristics of the proposed monitoring schemes are described. [Espanol] El Programa Universitario de Energia (PUE) de la Universidad Nacional Autonoma de Mexico (UNAM), a traves del proyecto {sup C}ontrol Ecologico del Campus Universitario{sup ,} tiene como objetivo instrumentar politicas de uso racional de la energia en las instalaciones universitarias. El PUE ha realizado una serie de actividades encaminadas a establecer un programa integral de administracion de la energia electrica en la UNAM. El programa mencionado debe considerar medidas de ahorro de energia (MAE) de tipo general y promover una serie de medidas particulares, para ser adecuadas e implantadas por cada una de las dependencias. El exito en el establecimiento de una serie de MAE, obliga a cuantificar sus efectos, registrarse y

  17. Development and implementation of a pilot network for continuous monitoring of electric energy; Desarrollo e implantacion de una red piloto de monitoreo continuo de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Cifuentes, A; Cortes Eslava, A [Facultad de Ingenieria, UNAM, Mexico, D. F. (Mexico)

    1998-12-31

    The ``Programa Universitario de Energia (PUE)`` (University Energy Program) of the Universidad Nacional Autonoma de Mexico (UNAM) through the project ``Ecologic Control of The University Campus`` has the objective of instrumenting policies for the rational use of the electric energy in the UNAM installations. The PUE has performed a series of activities aimed at the establishment of an integral program for the electric energy management in the UNAM. This program has to consider the measures for energy saving (MES) of general kind and to promote a series of specific measures to be adequated and implemented for each one of the departments. The success in establishing a series of MES compels to quantify its effects, to register and to analyze them to be in position of enhancing them, since it must be kept in mind that something that can not be measured can not be improved. For this purpose the PUE is developing a continuous monitoring pilot network of electric energy with local and remote access and an automated metering system. Two monitoring schemes are experimented, one commercial metering equipment and another one with own metering technology. In this paper the characteristics of the proposed monitoring schemes are described. [Espanol] El Programa Universitario de Energia (PUE) de la Universidad Nacional Autonoma de Mexico (UNAM), a traves del proyecto {sup C}ontrol Ecologico del Campus Universitario{sup ,} tiene como objetivo instrumentar politicas de uso racional de la energia en las instalaciones universitarias. El PUE ha realizado una serie de actividades encaminadas a establecer un programa integral de administracion de la energia electrica en la UNAM. El programa mencionado debe considerar medidas de ahorro de energia (MAE) de tipo general y promover una serie de medidas particulares, para ser adecuadas e implantadas por cada una de las dependencias. El exito en el establecimiento de una serie de MAE, obliga a cuantificar sus efectos, registrarse y

  18. Independent auto evaluation of an operative radiological protection program; Autoevaluacion independiente de un programa de proteccion radiologica operativa

    Energy Technology Data Exchange (ETDEWEB)

    Medrano L, M.A.; Rodriguez C, C.C.; Linares R, D.; Zarate M, N.; Zempoalteca B, R. [Gerencia Subsede Sureste Instituto Nacional de Investigaciones Nucleares, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: maam@nuclear.inin.mx

    2006-07-01

    The program of operative radiological protection of a nuclear power plant consists of multiple procedures and associate tasks that have as purpose the radiological protection of the workers of the power station. It is for this reason that the constant evaluation of the one it programs it is an important tool in the identification of their weaknesses (and strengths), so they can be assisted appropriately. In this work the main elements of the program of independent auto evaluation of the program of operative radiological protection of the Laguna Verde Central that has been developed and implemented by the National Institute of Nuclear Research are described. (Author)

  19. The electric power generation in Mexico and its environmental impacts: Past, present and future; La generacion electrica en Mexico y sus impactos ambientales: Pasado, presente y futuro

    Energy Technology Data Exchange (ETDEWEB)

    Quintanilla Martinez, Juan [Programa Universitario de Energia (PUE), Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1997-12-31

    The purpose of this paper is to analyze the historical evolution, past and present of the installed capacity and of the electric power generation, as well as the fuel consumption and the associated green-house gases emission. Also, under the technique of economic scenarios and future towns (in short and mediate terms) the potential needs of installed capacity, generation, mix and fuel consumption and associated green gases emissions is analyzed. Later on a comment is made on the energy implications of the substitution of fuels policies and the environmental Standards. Finally, a series of comments is established on the possible technological directions for the sector, from the stand point of generation efficiency and its effects in the reduction of emissions [Espanol] El proposito del presente trabajo es analizar la evolucion historica, pasada y presente, de la capacidad instalada y de la generacion electrica, asi como el consumo de combustibles y las emisiones de gases de invernadero asociadas. Tambien se analiza bajo la tecnica de escenarios economicos y poblaciones a futuro (en el corto y mediano plazo) las posibles necesidades de capacidad instalada, generacion, mezcla y consumo de combustibles y emisiones de gases de invernadero asociadas. Posteriormente se comenta sobre las implicaciones energeticas de las politicas de sustitucion de combustibles y estandares ambientales. Por ultimo se establecen una serie de comentarios sobre las posibles direcciones tecnologicas para el sector, desde el punto de vista de la eficiencia de generacion y sus efectos en la reduccion de las emisiones

  20. The satisfaction of developing a project of electrical energy saving; La satisfaccion de desarrollar un proyecto de ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Arreola Suarez, Alejandro [Hotel Club Marival, Nuevo Vallarta, Nayarit (Mexico)

    2002-09-01

    The projects for the energy saving in hotels represent a great opportunity to reduce the operation costs in the demand and consumption of electrical energy, since the existing facilities can take advantage of new technologies in illumination, air conditioning, refrigeration and heating. By their constitution, the hotels work the year around uninterruptedly and must provide all type of services to the guests and working personnel, which originates that they consume great amounts of energy in air conditioning, lightning, laundry, etc., since the prestige of the installation depends on it. [Spanish] Los proyectos para el ahorro de energia en hoteles representan una gran oportunidad para reducir costos de operacion en la demanda y consumo de energia electrica, ya que las instalaciones existentes pueden aprovechar nuevas tecnologias en iluminacion, aire acondicionado, refrigeracion y calefaccion. Por su constitucion, los hoteles trabajan ininterrumpidamente todo el ano y deben proporcionar toda clase de servicios a los huespedes y personal que labora, lo cual origina que consuman grandes cantidades de energia en aire acondicionado, iluminacion, lavanderia, etc., pues de ello depende el prestigio de la instalacion.

  1. Energy losses produced by differential currents in the metallic ducts of electric installations; Perdidas de energia producidas por corrientes diferenciales en la tuberia metalica de instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Campero L, Eduardo; Bratu S, Neagu; Marquez M, Luis; Caballero R, Rafael [Universidad Autonoma Metropolitana Unidad Azcapotzalco, Mexico, D. F. (Mexico)

    1994-12-31

    In this article it is explained what is known as differential currents and the conditions in which they appear in the electrical installations. A short outline is made on the magnetic induction phenomenon that appears in metallic conduits, due to the circulation of differential currents along the inside of the tube and that in turn produces energy losses in the form of heat, that is dissipated in the tube surrounding environment. The results of the measurements performed in the laboratory are shown in order to quantify the energy losses in the metallic conduit. It was found that for certain conditions these losses are significant. [Espanol] En este articulo se explica lo que se entiende por corrientes diferenciales y se describen las condiciones en las que estas aparecen en las instalaciones electricas. Se plantea brevemente el fenomeno de induccion magnetica que aparece en las tuberias metalicas, debido a la circulacion de corrientes diferenciales por el interior del tubo y que a su vez produce perdidas de energia en forma de calor, que se disipa en el ambiente que rodea al tubo. Se muestran los resultados de las mediciones que se llevaron a cabo en laboratorio para poder cuantificar las perdidas en tuberia metalica conduit. Se encontro que para ciertas condiciones estas perdidas son significativas.

  2. Participation of the research institutes in the safety aspects of the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Sanchez G, J.

    1991-01-01

    The main activities undertaken by two research institutes of Mexico, the Instituto de Investigaciones Electricas and the Instituto Nacional de Investigaciones Nucleares, related to the safety of the Laguna Verde Nuclear Power Plant, are described. Among these activities, the development of a system for data acquisition and analysis during pre-operational tests, the design and construction of a full-scope simulator, the in-core fuel management and the establishment of an equipment qualification laboratory, stand out. It is considered that there exists a large potential for further participation. (author)

  3. Co-generation project for the Combined Cycle Power Plant President Juarez Rosarito and a reverse osmosis desalting plant; Proyecto de cogeneracion para la planta de ciclo combinado Presidente Juarez Rosarito y una planta desaladora de osmosis inversa

    Energy Technology Data Exchange (ETDEWEB)

    Beltran Mora, Hector; Espindola Hernandez, Salvador [Universidad NAcional Autonoma de Mexico (UNAM), Mexico, D.F. (Mexico)

    2006-11-15

    In this work a technical and economical analysis of the installation of a reverse osmosis desalting plant connected to a power station that uses the combined cycle technology under a co-generation scheme is presented: production of electricity and water. The operation program of the desalting power station will be determined by the demand of energy of the combined cycle power station; the proposal is that the desalting plant operates in the hours of low load of the power station and shuts down at the peak hours of electrical energy demand. So that this study is representative, the demand curves of electric energy of the units of combined cycle of Central President Juarez Rosarito of the Comision Federal de Electricidad (CFE) have been taken and updated the data of the reverse osmosis desalting plants that are available at the moment in the market. As basis of the study the level costs will be determined so much as the electrical energy generated by the power station of combined cycle, operating inside and outside of a co-generation scheme and the costs made level for the water produced by the reverse osmosis plant under two assumptions: the first one is buying the electrical energy from CFE and the second one considering that the CFE is the owner of the desalting plant and therefore the cost of electrical energy to desalting the plant is zero. This work shows the economic impacts on the costs of the generation of electrical energy and on those of the desalted water in a co-generation scheme. The results shown in this study can be considered for the future planning in the construction of desalting plants to supply of water in the Northwestern zones of the country where serious problems of water shortage exist. [Spanish] En este trabajo se presenta un analisis tecnico y economico de la instalacion de una planta desaladora de osmosis inversa acoplada a una central de generacion de energia electrica que utiliza la tecnologia de ciclo combinado bajo un esquema de

  4. Electrical generation of nuclear origins in Spain 95/96; Generacion electrica de origen nuclear en Espana 95/96

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    The paper presents nuclear programme of Spain and reviews the following issues: LWR plants in Spain; nuclear fuel cycle; fuel assemblies manufacturing; reload core engineering experience; fuel assemblies significant features; fuel rod failures causes; fuel related R and D projects and irradiation programs; high burnup fuel behaviour.

  5. Notes on the Start-Up of the Latina Power Station; Notes concernant le demarrage de la centrale nucleaire de Latina; Zapusk ehlektrostantsii Latina; Notas sobre la puesta en marcha de la central electrica de Latina

    Energy Technology Data Exchange (ETDEWEB)

    Calabria, G.; Gualtieri, G. [AGIP Nucleare, Milano (Italy)

    1963-10-15

    Information is given on the start-up of the first Italian nuclear power plant, the Latin Power Station, designed for an electrical output of 200 MW, incorporating a natural uranium-gas-graphite reactor. After a brief description of the main characteristics of the station, details are given on die performance of the final tests of the plant, on the fuel loading and on the sequence of commissioning operations, measurements and controls subsequent to the criticality attained. The operations for the start-up and connection of the station to the electrical network are treated. The organization problems relevant to the station operation including personnel preparation and qualification, safety measures, are also illustrated. (author) [French] Le memoire donne des renseignements sur le demarrage de la premiere centrale nucleaire italienne, la centrale de Latina, dont la puissance electrique est de 200 MW et qui fonctionne avec un reacteur du type uranium naturel-gaz-graphite. Apres une breve description des caracteristiques essentielles de la centrale, des explications detaillees sont donnees sur les resultats des derniers essais auxquels elle a ete soumise, sur le chargement du combustible et sur la serie des operations de mise en service, des mesures et des verifications auxquelles il a ete procede lorsque l'etat critique a ete atteint. Les operations de demarrage et de raccordement de la centrale au reseau electrique sont etudiees dans le memoire, ainsi que les problemes d'organisation que pose l 'exploitation de la centrale, notamment en ce qui concerne la formation du personnel et les mesures de securite. (author) [Spanish] Se comunican datos sobre la puesta en marcha de la primera central nucleoelectrica italiana, en Latina, proyectada para desarrollar una potencia de 200 MW (e), que se basa en un reactor de uranio natural moderado por grafito u refrigerado por gas. Despues de describir brevemente las caracteristicas de la central, se dan detalles sobre el

  6. Radiation protection of patients in medical exposures: regional project IAEA 2007-2008 RLA/9/57;Proteccion radiologica de pacientes en exposiciones medicas: proyecto regional IAEA 2007-2008 RLA/9/57

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    -area product (Pk, a); Mammography theme contains: Application and criteria for image quality: a study of the mammography - skull flow, Sheet for data collection in patients CC and MLO, Sheet for data collection in mammography practices, include equipment description, determination of yields, Hemi reducer thickness, determination of {sup c,} data from the patient and glandular dose; Tomography theme contains: General data about computed tomography services in the Hospital Max Peralta which include report of tests and dosimetry in phantom, in air, information from used scanners; Radiology theme contains: Dosimetry of patients in general radiology where shows forms for determining the performance of x-ray tube; Minimum values, maximum and Kerma in air average in surface of entry for PA Chest radiographs; Measures to generate the yield curve; Patient data, the technical parameters and image quality; Forms by country; Kerma in air at the entrance to the PA Chest skin, the dosimetry in general radiology is included with practices and methodology for the measurement and evaluation, also shows forms with protocols for measurements with TLDS;La proteccion radiologica de pacientes en exposiciones medicas como proyecto esta integrado por 5 regionales que abarcan unos 80 paises, 94 hospitales y 120 actividades relacionadas con radiologia y radiacion. Un taller fue desarrollado con los siguientes objetivos: proporcionar los elementos teoricos y practicos para que los profesionales en proteccion radiologica de pacientes desarrollen tareas encomendadas, identificar la metodologia de medicion mediante hojas para la captura de datos e interpretacion de los mismos, realizar ejercicios practicos de los procedimientos a aplicar en radiologia, mamografia, tomografia computarizada e intervencionismo. Dicho taller se dividio en secciones teoricas y practicas, secciones de analisis e interpretacion de datos y un examen final. Este proyecto pretende identificar fortalezas y debilidades, objetivos

  7. Radiation protection of patients in medical exposures: regional project IAEA 2007-2008 RLA/9/57; Proteccion radiologica de pacientes en exposiciones medicas: proyecto regional IAEA 2007-2008 RLA/9/57

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    -area product (Pk, a); Mammography theme contains: Application and criteria for image quality: a study of the mammography - skull flow, Sheet for data collection in patients CC and MLO, Sheet for data collection in mammography practices, include equipment description, determination of yields, Hemi reducer thickness, determination of {sup c,} data from the patient and glandular dose; Tomography theme contains: General data about computed tomography services in the Hospital Max Peralta which include report of tests and dosimetry in phantom, in air, information from used scanners; Radiology theme contains: Dosimetry of patients in general radiology where shows forms for determining the performance of x-ray tube; Minimum values, maximum and Kerma in air average in surface of entry for PA Chest radiographs; Measures to generate the yield curve; Patient data, the technical parameters and image quality; Forms by country; Kerma in air at the entrance to the PA Chest skin, the dosimetry in general radiology is included with practices and methodology for the measurement and evaluation, also shows forms with protocols for measurements with TLDS;La proteccion radiologica de pacientes en exposiciones medicas como proyecto esta integrado por 5 regionales que abarcan unos 80 paises, 94 hospitales y 120 actividades relacionadas con radiologia y radiacion. Un taller fue desarrollado con los siguientes objetivos: proporcionar los elementos teoricos y practicos para que los profesionales en proteccion radiologica de pacientes desarrollen tareas encomendadas, identificar la metodologia de medicion mediante hojas para la captura de datos e interpretacion de los mismos, realizar ejercicios practicos de los procedimientos a aplicar en radiologia, mamografia, tomografia computarizada e intervencionismo. Dicho taller se dividio en secciones teoricas y practicas, secciones de analisis e interpretacion de datos y un examen final. Este proyecto pretende identificar fortalezas y debilidades, objetivos

  8. Energy saving by means of air conditioning equipment replacement and the household application of thermal insulation; Ahorro de energia electrica por reemplazo de equipos de aire acondicionado y aplicacion de aislamiento termico en viviendas

    Energy Technology Data Exchange (ETDEWEB)

    Peralta Solorio, Jose Luis [Fideicomiso para el Ahorro de la Energia (Mexico)

    2005-07-15

    An extension study of the Financing Program for Energy Saving looked for the evaluation of the electric energy saving potential obtained by the replacement of air conditioning equipment and the application of thermal insulation in 30 houses of two Mexican cities with warmth climate. In a joint effort with Comision Federal de Electricidad the consumption files of the users were analyzed and field measurements of electric demand and of refrigeration were made. As a following step the change of the refrigeration necessities derived from the application of thermal insulation were evaluated as well as the energy efficiency improvement obtained by the substitution of the air conditioning equipment and the favorable results obtained by the implementation of both measures - thermal insulation and change of air conditioning equipment in a joint form. This way, as a conclusion, the optimum sequence of application of these measures is revealed. [Spanish] Un estudio extension del Programa de Financiamiento para el Ahorro de Energia Electrica busco evaluar el potencial de ahorro de energia electrica alcanzado por el reemplazo de equipos de aire acondicionado y la aplicacion de aislamiento termico en 30 viviendas de dos ciudades mexicanas con clima calido. En un esfuerzo conjunto con la Comision Federal de Electricidad se analizaron los historiales de consumo de los usuarios y se efectuaron las mediciones de campo de demanda electrica y de refrigeracion. Como paso siguiente se valoro el cambio en las necesidades de refrigeracion derivado de la aplicacion de aislamiento termico al igual que la mejora en eficiencia energetica obtenida por la sustitucion de aire acondicionado y se identificaron los resultados favorecedores arrojados por la implementacion de ambas medidas -aislamiento termico y cambio de equipo de aire acondicionado- en forma conjunta. De esta manera, como conclusion, se devela la mas optima secuencia de aplicacion de estas medidas.

  9. The use of reflecting paints on building`s roofs for energy saving; Uso de pinturas reflejantes en los techos de las edificaciones para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Valera Negrete, Jose Adrian [Programa de Ahorro de Energia del Sector Electrico (PAESE), Comision Federal de Electricidad, Mexico, D. F. (Mexico); Sanchez Soto, Ramon [Facultad de Ingenieria, Departamento de Termoenergia de la UNAM, Mexico, D. F. (Mexico)

    1998-12-31

    This paper shows the effects of the use of reflecting paints in different colors on the buildings roofs and the results in energy saving obtained in a field test carried on in Monterrey, Nuevo Leon State of Mexico using aluminum paint. [Espanol] El presente trabajo muestra los efectos del uso de pinturas reflejantes de diferentes colores en los techos de edificaciones, y los resultados de ahorro de energia electrica obtenidos en una prueba de campo efectuada en Monterrey, Nuevo Leon, Mexico, utilizando pintura de aluminio.

  10. The use of reflecting paints on building`s roofs for energy saving; Uso de pinturas reflejantes en los techos de las edificaciones para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Valera Negrete, Jose Adrian [Programa de Ahorro de Energia del Sector Electrico (PAESE), Comision Federal de Electricidad, Mexico, D. F. (Mexico); Sanchez Soto, Ramon [Facultad de Ingenieria, Departamento de Termoenergia de la UNAM, Mexico, D. F. (Mexico)

    1999-12-31

    This paper shows the effects of the use of reflecting paints in different colors on the buildings roofs and the results in energy saving obtained in a field test carried on in Monterrey, Nuevo Leon State of Mexico using aluminum paint. [Espanol] El presente trabajo muestra los efectos del uso de pinturas reflejantes de diferentes colores en los techos de edificaciones, y los resultados de ahorro de energia electrica obtenidos en una prueba de campo efectuada en Monterrey, Nuevo Leon, Mexico, utilizando pintura de aluminio.

  11. Algorithms for the evaluation of the reliability of networks and substations; Algoritmos para evaluar la confiabilidad de redes y subestaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Vega Ortiz, Miguel [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    Two algorithms are presented, one for analyzing the reliability of networks and another one to analyzing the reliability of electrical substations. The algorithms model a network or a substation by means of a graph and determine all the exits, of up to third degree, which isolates the load points. The algorithm that is used for the network analysis, is the one of p-cuts and in the case of the substations it is the one of minimum ways, for later, from these minimum p-cuts and of the minimum ways, obtains the minimum cuts. These minimum cuts are evaluated with the approximate method and give as a result the system reliability and of each one of the components that have been modeled. At the end some examples and results obtained are shown. As case of study, the algorithm is applied to two substations arrangements and to a network of industrial distribution, but it is possible to be applied to transmission and distribution networks. [Spanish] Se presentan dos algoritmos, uno para analizar la confiabilidad de redes y otro para analizar la confiabilidad de subestaciones electricas. Los algoritmos modelan una red o una subestacion por medio de un grafo y determinan todas las salidas, de hasta tercer grado, que aislan los puntos de carga. El algoritmo que se utiliza para el analisis de redes, es el de p-cortes y en el caso de las subestaciones es el de caminos minimos, para despues, a partir de estos p-cortes minimos y de los caminos minimos, obtener los cortes minimos. Estos cortes minimos se evaluan con el metodo aproximado y dan como resultado la confiabilidad del sistema y de cada una de las componentes que se hayan modelado. Al final se muestran algunos ejemplos y resultados obtenidos. Como caso de estudio, el algoritmo se aplica a dos arreglos de subestaciones y a una red de distribucion industrial, pero se puede aplicar a redes de transmision y de distribucion.

  12. The presence of harmonics in electric installations and some of its consequences; La presencia de corrientes armonicas en instalaciones electricas y algunas de sus consecuencias

    Energy Technology Data Exchange (ETDEWEB)

    Bratu Serban, Neagu; Campero Littlewood, Eduardo [Universidad Autonoma Metropolitana Azcapotzalco, Mexico, D. F. (Mexico)

    1996-12-31

    This paper is a short introduction to how the sinusoidal voltage waves are generated. A revision is made on the way of representing a distorted wave and the way of quantifying its harmonics content (harmonics distortion). An overview is made of the non-lineal consuming elements that produce distortion of the current waves. A revision is made on the concept of a power factor in conditions of waves with harmonic distortion. The consequences of feeding with distorted waves the different devices such as motors (particularly for the distortion originated by the rectifiers and the velocity electronic controls), transformers and capacitors. Mention is made of some of the methods for not to produce or for reducing the harmonic effect in the electric networks. The purpose of this article is to review the consequences on energy consumption by the presence of harmonics. [Espanol] En este articulo se hace una breve introduccion de la forma en que se generan las ondas senoidales de voltaje. Se revisa la manera de representar una onda distorsionada y la manera de cuantificar su contenido de armonicas (distorsion armonica). Se repasan los elementos consumidores no lineales que producen la deformacion de las ondas de corriente. Se revisa el concepto de factor de potencia en condiciones de ondas con distorsion armonica. Se analizan las consecuencias de alimentar con ondas distorsionadas a diferentes equipos como motores (particularmente por la distorsion originada por los rectificadores y los controladores de velocidad electronicos), transformadores y capacitores. Se mencionan algunos metodos para no producir, o reducir el efecto armonico en las redes electricas. El proposito de este articulo es revisar las consecuencias sobre el consumo de energia por la presencia de armonicas.

  13. Online monitoring of accessories for underground electrical installations through acoustics emissions; Monitoreo en linea de accesorios de instalaciones electricas subterraneas mediante emisiones acusticas

    Energy Technology Data Exchange (ETDEWEB)

    Casals-Torrens, P. [Universidad Politecnica de Cataluna, Barcelona (Espana)]. E-mail: p.casals@upc.edu; Gonzalez-Parada, A. [Universidad de Guanajuato, Guanajuato (Mexico)]. E-mail: gonzaleza@salamanca.ugto.mx; Bosch-Tous, R. [Universidad Politecnica de Cataluna, Barcelona (Espana)

    2012-04-15

    The acoustic waves caused by Partial Discharges inside the dielectric materials, can be detected by acoustic emission (AE) sensors and analyzed in the time domain. The experimental results presented, show the online detection capability of these sensors in the environment near a cable accessory, such as a splice or terminal. The AE sensors are immune to electromagnetic interference and constitute a detection method non-intrusive and non-destructive, which ensures a galvanic decoupling with respect to electric networks, this technique of partial discharge detection can be applied as a test method for preventive or predictive maintenance (condition-based maintenance) to equipment or facilities of medium and high voltage in service and represents an alternative method to electrical detection systems, conventional or not, that continue to rely on the detection of current pulses. This paper presents characterization tests of the sensors AE through comparative tests of partial discharge on accessories for underground power cables. [Spanish] Las ondas acusticas provocadas por las descargas parciales en el interior de un dielectrico pueden ser detectadas por sensores de Emisiones Acusticas (EA) y analizadas en el dominio del tiempo. Los resultados experimentales que se presentan, evidencian la capacidad de deteccion en linea de estos sensores, en el entorno proximo a un accesorio de cable, empalme o terminal. Los sensores EA son inmunes a las interferencias electromagneticas, son un metodo de deteccion no destructivo y garantizan desacople galvanico respecto a la red electrica; esta tecnica de deteccion de descargas parciales puede ser aplicada como metodo de prueba para mantenimiento preventivo o predictivo (mantenimiento basado en la condicion), en equipos o instalaciones de media y alta tension en servicio, y representa una alternativa a los sistemas electricos de deteccion, convencionales o no, que continuan basandose en la deteccion del impulsos de corriente. En el

  14. The presence of harmonics in electric installations and some of its consequences; La presencia de corrientes armonicas en instalaciones electricas y algunas de sus consecuencias

    Energy Technology Data Exchange (ETDEWEB)

    Bratu Serban, Neagu; Campero Littlewood, Eduardo [Universidad Autonoma Metropolitana Azcapotzalco, Mexico, D. F. (Mexico)

    1997-12-31

    This paper is a short introduction to how the sinusoidal voltage waves are generated. A revision is made on the way of representing a distorted wave and the way of quantifying its harmonics content (harmonics distortion). An overview is made of the non-lineal consuming elements that produce distortion of the current waves. A revision is made on the concept of a power factor in conditions of waves with harmonic distortion. The consequences of feeding with distorted waves the different devices such as motors (particularly for the distortion originated by the rectifiers and the velocity electronic controls), transformers and capacitors. Mention is made of some of the methods for not to produce or for reducing the harmonic effect in the electric networks. The purpose of this article is to review the consequences on energy consumption by the presence of harmonics. [Espanol] En este articulo se hace una breve introduccion de la forma en que se generan las ondas senoidales de voltaje. Se revisa la manera de representar una onda distorsionada y la manera de cuantificar su contenido de armonicas (distorsion armonica). Se repasan los elementos consumidores no lineales que producen la deformacion de las ondas de corriente. Se revisa el concepto de factor de potencia en condiciones de ondas con distorsion armonica. Se analizan las consecuencias de alimentar con ondas distorsionadas a diferentes equipos como motores (particularmente por la distorsion originada por los rectificadores y los controladores de velocidad electronicos), transformadores y capacitores. Se mencionan algunos metodos para no producir, o reducir el efecto armonico en las redes electricas. El proposito de este articulo es revisar las consecuencias sobre el consumo de energia por la presencia de armonicas.

  15. Internal Arc: People safety in the electrical wiring; Arco interno: Seguridad de las personas ante instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Inchausti, J. M.

    2009-07-01

    The aim of this article is to describe the internal arc phenomenon, an extremely fast, almost explosive and unattended process of transformation form an initial electric power to the generation of a pressure and heat wave inside the medium its produced its consequences for safety, current methods of limiting them and current regulations in general for equipment used in medium-voltage electrical distribution networks. Taking into account that this type of equipment is found thought the distribution network in both public buildings and unrestricted access areas, safety (of operators and the general public) must be taken into account in the design of equipment and installations to minimize the risk of internal arcs occurring. This is the gist of, for example, ITC 16 of the Spanish Regulation on Power Plants and transformer substations. In addition to the construction aspects specific to each device in which the manufacturer has to takes steps to minimize the risks of an internal arcs occurring. This is the gist of, for example, ITC 16 of the Spanish Regulation on Power Plants and transformer substations. In addition to the construction aspects specific to each device in which an internal arc occurring, it is understood to be vitally important that users, installers and designers of Medium Voltage installations are familiar with the installation conditions stated by the manufacturer and thus avoid risks. (Author) 14 refs.

  16. The optimization of electric motors repair techniques as a mean for electric energy saving; La optimizacion de las tecnicas de reparacion de motores electricos como un medio para ahorrar energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Zagal Leon, Juan Ruben [Fideicomiso para el Ahorro de Energia Electrica (FIDE), Mexico, D. F. (Mexico)

    1998-12-31

    This paper presents, in a very concise, which are the techniques to optimize the electric motors repair made by the Fideicomiso para el Ahorro de Energia Electrica (FIDE), the loss of efficiency that might exist after repairing an electric motor, as well as the procedures to perform an optimum reparation of the electric motors. Furthermore, some recommendations are given for the selection of an adequate rewinding shop to guarantee that the motor does not suffer efficiency losses after its repair. [Espanol] Este trabajo presenta, de manera muy concreta, cuales son las tecnicas para optimizar las tecnicas de reparacion de motores electricos realizado por el Fideicomiso para el Ahorro de Energia Electrica (FIDE), el nivel de perdida de eficiencia que puede existir despues de reparar un motor electrico, asi como los procedimientos para realizar una optima reparacion en motores electricos. Asimismo, se proporcionan algunas recomendaciones para seleccionar un taller de reembobinado adecuado para garantizar que el motor no sufra perdidas de eficiencia despues de su reparacion.

  17. The optimization of electric motors repair techniques as a mean for electric energy saving; La optimizacion de las tecnicas de reparacion de motores electricos como un medio para ahorrar energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Zagal Leon, Juan Ruben [Fideicomiso para el Ahorro de Energia Electrica (FIDE), Mexico, D. F. (Mexico)

    1999-12-31

    This paper presents, in a very concise, which are the techniques to optimize the electric motors repair made by the Fideicomiso para el Ahorro de Energia Electrica (FIDE), the loss of efficiency that might exist after repairing an electric motor, as well as the procedures to perform an optimum reparation of the electric motors. Furthermore, some recommendations are given for the selection of an adequate rewinding shop to guarantee that the motor does not suffer efficiency losses after its repair. [Espanol] Este trabajo presenta, de manera muy concreta, cuales son las tecnicas para optimizar las tecnicas de reparacion de motores electricos realizado por el Fideicomiso para el Ahorro de Energia Electrica (FIDE), el nivel de perdida de eficiencia que puede existir despues de reparar un motor electrico, asi como los procedimientos para realizar una optima reparacion en motores electricos. Asimismo, se proporcionan algunas recomendaciones para seleccionar un taller de reembobinado adecuado para garantizar que el motor no sufra perdidas de eficiencia despues de su reparacion.

  18. Results of the Service of External Dosimetry of the Centro de Proteccion e Higiene de las Radiaciones (CPHR), Cuba during the biennium 2010 - 2011; Resultados del servicio de dosimetria externa del CPHR durante el bienio 2010-2011

    Energy Technology Data Exchange (ETDEWEB)

    Molina Perez, Daniel; Verdecia Sanchez, Maribel; Castro Soler, Ailza; Farrada Neyra, Yamilia, E-mail: daniel@cphr.edu.cu [Laboratorio de Dosimetria Externa (LDE), Centro de Proteccion e Higiene de las Radiaciones (CPHR), La Habana (Cuba)

    2013-07-01

    The Service of Personal Dosimetry of the External Dosimetry Laboratory of the Centro de Proteccion y Higiene de las Radiaciones - CPHR of Cuba works with an automatic RADOS TLD system and includes the surveillance of the doses of whole body and extremities for photon radiation. The work presents the results of the service in the period 2010-2011, showing data related to the number and distribution of workers monitored for areas. The levels of occupational exposure area analyzed using various indicators such as: annual average dose for areas, number of workers who receive annual doses greater than zero, distribution of workers by dose intervals, and others. These indicators are compared with previous periods and with the values published by the UNSCEAR. In general, the average annual dose for all areas was less than 1 mSv for whole body and 3 mSv for hands. The number of exposed workers experienced significant variation from one year to another, considerably decreasing from 60% to 12% of the total. The work presents an analysis of this behavior and highlights that the country guarantees the personal dosimetry to 100% of exposed workers and that the results of the occupational exposure are within the established requirements.

  19. Hydraulic speed variators for electrical energy saving; Variadores de velocidad hidraulicos para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Valera Negrete, Adrian [Programa de Ahorro de Energia del Sector Electrico (PAESE), Mexico, D. F. (Mexico)

    1999-07-01

    This paper shows the characteristics and applications of the hydraulic speed variators, where because of the conditions of the industrial processes it is necessary to vary the operation parameters, obtaining therefore an energy saving besides improving the control of these processes. In addition, the technical and economic evaluation is presented of a project of the Mazatlan Fossil Power Plant, in which it is intended to invest in the installation of a hydraulic speed variator connected to the forced draft fan of unit number three, which operates with an induction motor of 1,865 kW (2,500 H.P.), with a Voltage of 4,180 V at 1,180 rpm. [Spanish] El presente trabajo muestra las caracteristicas y aplicaciones de los variadores de velocidad hidraulicos, donde por las condiciones de los procesos industriales sea necesario variar los parametros de operacion, obteniendose asi un ahorro de energia ademas de mejorar el control de dichos procesos. Se presenta ademas la evaluacion tecnica y economica de un proyecto de la Planta Termoelectrica Mazatlan, en donde se pretende invertir en la instalacion de un variador de velocidad hidraulico acoplado al ventilador de tiro forzado de la unidad numero tres, el cual opera con un motor de induccion de 1,865 kW (2,500 H.P.), con un voltaje de 4,180 V y una velocidad de 1,180 rpm.

  20. End uses of electric energy in homes of a group of dwellings; Usos finales de la energia electrica en hogares de un conjunto habitacional

    Energy Technology Data Exchange (ETDEWEB)

    Campero Littlewood, E.; Romero Cortes, J.; Alarcon Maldonado, E.; Silva Oliver, J.; Ortiz Segura, J.; Vargas Rubio, J. [Departamento de Energia, Universidad Autonoma Metropolitana - Unidad Azcapotzalco, Mexico, D. F. (Mexico)

    1997-12-31

    ). El analisis de la informacion permite conocer la capacidad de consumo de energia electrica que tienen las viviendas de la muestra y a hacer inferencias de la capacidad de consumo de la unidad habitacional.

  1. End uses of electric energy in homes of a group of dwellings; Usos finales de la energia electrica en hogares de un conjunto habitacional

    Energy Technology Data Exchange (ETDEWEB)

    Campero Littlewood, E; Romero Cortes, J; Alarcon Maldonado, E; Silva Oliver, J; Ortiz Segura, J; Vargas Rubio, J [Departamento de Energia, Universidad Autonoma Metropolitana - Unidad Azcapotzalco, Mexico, D. F. (Mexico)

    1998-12-31

    ). El analisis de la informacion permite conocer la capacidad de consumo de energia electrica que tienen las viviendas de la muestra y a hacer inferencias de la capacidad de consumo de la unidad habitacional.

  2. Gasification of heavy fuels to produce electrical energy and hydrogen; Gasificacion de combustibles pesados para producir energia electrica e hidrogeno

    Energy Technology Data Exchange (ETDEWEB)

    Vera Garcia, Oscar Alberto [Universidad Nacional Autonoma de Mexico(UNAM), Mexico, D.F. (Mexico)

    2006-11-15

    A description is presented of the different types of integrated gasifiers that at the moment are used in the synthesis gas production to be used, with different fuels in the generation of electricity in Combined Cycle. Three cases of application of integrated gasifiers are analyzed. The first it is the engine power upgrade of a Combined Cycle power plant to natural gas to burn fuel of bad quality in an integrated gasifier (CCGI). The second one examines the incorporation of a shift reactor in which the synthesis gas is transformed into CO{sub 2} and H{sub 2} which are used to move the turbine to gas, adapted for pure hydrogen. Finally is studied the amount of other by-products that can be obtained from these co-generation cycles such as CO{sub 2} to be used in secondary recovery of oil wells, N{sub 2} to be used in the fertilizer industry or in the proper oil production and H{sub 2} to be used in the oil industry or the generation with fuel cells. All the cases are studied in quantitative form, making the balance of mass and energy of each one of them. In order to give more practical sense to the calculations, the engineering data of the Valladolid Power station of Comision Federal de Electricidad (CFE) have been taken as base. This article provides a basic idea, but very practical, to estimate the fuel consumption of the different modes of arrangement of a CCGI power station, as well as the volumes of the different gases that can be produced and the modifications to the size of the equipment that is required. [Spanish] Se presenta una descripcion de los diferentes tipos de gasificadores integrados que actualmente se utilizan en la produccion de gas de sintesis para ser utilizados, con diferentes combustibles, en la generacion de electricidad con Ciclo Combinado. Se analizan tres casos de aplicacion de gasificadores integrados. El primero es la repotenciacion de una planta de Ciclo Combinado a gas natural para quemar combustible de mala calidad en un gasificador

  3. Hybrid system of generating electricity, solar eolic diesel San Juanico, Baja California Sur, Mexico; Sistema hibrido de generacion electrica, eolico solar diesel San Juanico, Baja California Sur, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Huerta, Javier [Comision Federal de Electricidad, La Paz, Baja California Sur (Mexico); Johnston, Peter [Technology Development, Arizona (United States); Napikoski, Chester [Generation Engineering, Arizona (United States); Escutia, Ricardo [Comision Federal de Electricidad, Baja California Sur (Mexico)

    2000-07-01

    that is generated thru the selling of electric energy, guarantees the sustainable operation of the system. [Spanish] La Comision Federal de Electricidad (CFE), y la empresa electrica norteamericana Arizona Public Service (APS), firmaron un convenio de colaboracion para desarrollar un proyecto de generacion de energia electrica con la utilizacion de energias renovables. Las premisas que se acordaron fueron las siguientes: 1. Enfoque del proyecto hacia una comunidad rural. 2. El costo de la obra debera ser menor al de su interconexion con el sistema convencional. 3. Aceptacion por parte de la comunidad, y autoridades gubernamentales. 4. Sustentabilidad de la operacion del sistema. Se efectuaron diversos analisis tecnicos y economicos asi como la evaluacion del recurso solar y eolico, estudio de impacto ambiental, plan de negocios para obtener la aprobacion de los recursos economicos ante instancias como Niagara Mohawk (NIMO), y la USAID, mediante la supervision de los Laboratorios Nacionales de Sandia. Despues de efectuarse las mediciones anemometricas y de radiacion solar, en diversas comunidades, se considero a la comunidad de San Juanico como la mas viable; tambien los aspectos de logistica, sociales, tamano de la comunidad y como detonador para las actividades economicas como la pesca y el turismo. La APS llevo a cabo el proyecto ejecutivo de conformidad con las recomendaciones de la Comision Federal de Electricidad. El proyecto consistio basicamente en la instalacion de 10 aerogeneradores de 10 Kw. c/u, un arreglo solar de 17 Kw., un inversor de 70 Kw., un banco de baterias de 432 Kwh., mas un motogenerador diesel de emergencia de 80 Kw. Ademas de la obra civil y electromecanica. Fue necesario involucrar a la poblacion en el conocimiento y seguimiento del proyecto desde sus inicios, ya que consideramos que este factor seria indispensable para lograr el exito del mismo. Se instalaron lamparas ahorradoras de energia en viviendas y alumbrado publico para optimizar el

  4. Hybrid system of generating electricity, solar eolic diesel San Juanico, Baja California Sur, Mexico; Sistema hibrido de generacion electrica, eolico solar diesel San Juanico, Baja California Sur, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Huerta, Javier [Comision Federal de Electricidad, La Paz, Baja California Sur (Mexico); Johnston, Peter [Technology Development, Arizona (United States); Napikoski, Chester [Generation Engineering, Arizona (United States); Escutia, Ricardo [Comision Federal de Electricidad, Baja California Sur (Mexico)

    2000-07-01

    is generated thru the selling of electric energy, guarantees the sustainable operation of the system. [Spanish] La Comision Federal de Electricidad (CFE), y la empresa electrica norteamericana Arizona Public Service (APS), firmaron un convenio de colaboracion para desarrollar un proyecto de generacion de energia electrica con la utilizacion de energias renovables. Las premisas que se acordaron fueron las siguientes: 1. Enfoque del proyecto hacia una comunidad rural. 2. El costo de la obra debera ser menor al de su interconexion con el sistema convencional. 3. Aceptacion por parte de la comunidad, y autoridades gubernamentales. 4. Sustentabilidad de la operacion del sistema. Se efectuaron diversos analisis tecnicos y economicos asi como la evaluacion del recurso solar y eolico, estudio de impacto ambiental, plan de negocios para obtener la aprobacion de los recursos economicos ante instancias como Niagara Mohawk (NIMO), y la USAID, mediante la supervision de los Laboratorios Nacionales de Sandia. Despues de efectuarse las mediciones anemometricas y de radiacion solar, en diversas comunidades, se considero a la comunidad de San Juanico como la mas viable; tambien los aspectos de logistica, sociales, tamano de la comunidad y como detonador para las actividades economicas como la pesca y el turismo. La APS llevo a cabo el proyecto ejecutivo de conformidad con las recomendaciones de la Comision Federal de Electricidad. El proyecto consistio basicamente en la instalacion de 10 aerogeneradores de 10 Kw. c/u, un arreglo solar de 17 Kw., un inversor de 70 Kw., un banco de baterias de 432 Kwh., mas un motogenerador diesel de emergencia de 80 Kw. Ademas de la obra civil y electromecanica. Fue necesario involucrar a la poblacion en el conocimiento y seguimiento del proyecto desde sus inicios, ya que consideramos que este factor seria indispensable para lograr el exito del mismo. Se instalaron lamparas ahorradoras de energia en viviendas y alumbrado publico para optimizar el

  5. Digital viscosity controller for fossil power plants; Controlador digital de viscosidad para plantas termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Bautista B, Amberto; Ocampo P, Carlos; Gutierrez A, Ruben; Madinaveitia V, Miguel [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1990-12-31

    Upon the need of increasing the efficiency of the existing fossil power plants in Mexico, the Instrumentation and Control Department of the Instituto de Investigaciones Electricas (IIE) designed and built a viscosity controller to enhance the fuel oil heating process. The system strategy, that allows the control either by temperature or viscosity considers, as an important element, the changing characteristics of the supplied fuels. The equipment that is utilized forms apart of the line Acquisition and Control System (ACS) developed at the same Institute, that has been successfully applied in other systems. [Espanol] Ante la necesidad de aumentar la eficiencia de las plantas termoelectricas existentes en Mexico, el Departamento de Instrumentacion y Control, del Instituto de Investigaciones Electricas (IIE), diseno y construyo un controlador de viscosidad para mejorar el proceso de calentamiento del aceite combustible. La estrategia del sistema, que permite controlar ya sea por viscosidad o por temperatura, considera como elemento importante las caracteristicas cambiantes de los combustibles suministrados. El equipo que se utiliza forma parte de la linea SAC (sistema de adquisicion y control), desarrollada en el mismo Instituto, que se ha aplicado satisfactoriamente en otros sistemas.

  6. Digital viscosity controller for fossil power plants; Controlador digital de viscosidad para plantas termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Bautista B, Amberto; Ocampo P, Carlos; Gutierrez A, Ruben; Madinaveitia V, Miguel [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1989-12-31

    Upon the need of increasing the efficiency of the existing fossil power plants in Mexico, the Instrumentation and Control Department of the Instituto de Investigaciones Electricas (IIE) designed and built a viscosity controller to enhance the fuel oil heating process. The system strategy, that allows the control either by temperature or viscosity considers, as an important element, the changing characteristics of the supplied fuels. The equipment that is utilized forms apart of the line Acquisition and Control System (ACS) developed at the same Institute, that has been successfully applied in other systems. [Espanol] Ante la necesidad de aumentar la eficiencia de las plantas termoelectricas existentes en Mexico, el Departamento de Instrumentacion y Control, del Instituto de Investigaciones Electricas (IIE), diseno y construyo un controlador de viscosidad para mejorar el proceso de calentamiento del aceite combustible. La estrategia del sistema, que permite controlar ya sea por viscosidad o por temperatura, considera como elemento importante las caracteristicas cambiantes de los combustibles suministrados. El equipo que se utiliza forma parte de la linea SAC (sistema de adquisicion y control), desarrollada en el mismo Instituto, que se ha aplicado satisfactoriamente en otros sistemas.

  7. Comparative analysis of the indexes of electric power density in buildings lighting systems; Analisis comparativo de los indices de densidad de potencia electrica de los sistemas de alumbrado en edificios

    Energy Technology Data Exchange (ETDEWEB)

    Cruz Hernandez, J.I.; Morillon Galvez, D. [CONAE, Mexico, D. F. (Mexico)

    1995-12-31

    The national situation of the lighting systems in buildings is presented in order to know its consumption and make comparisons in accordance with the terms of the Electric Power Density that the lighting systems must satisfy, recently published in the norm, NOM 007 ENER-1995 (Energy Efficiency for non Residential Buildings` Lighting Systems). The form of application of the norm to determine the Electric Power Density Indexes in Lighting Buildings (EPDIL) is described, which permitted to know the current situation of the lighting systems, to compare the results internationally and with the ones specified in the proper norm. As a conclusion, there is the need of enhancing the efficiency of the lightning systems, with savings technologies, improve the lightning levels and equalize the energy indexes of the EPDIL with the ones recommended. [Espanol] Se presenta un estudio sobre la situacion nacional de los sistemas de alumbrado en edificios, con el objeto de conocer su consumo y compararlos, de acuerdo a los terminos de densidad de potencia electrica que deben cumplir los sistemas de alumbrado, publicados recientemente en la norma, NOM 007 ENER-1995 (Eficiencia Energetica para los Sistemas de Alumbrado en Edificios no Residenciales). Se describe la forma de aplicar la norma para determinar los indices de densidad de potencia electrica en alumbrado (DPEA) en edificios, lo cual permitio conocer la situacion actual de los sistemas de alumbrado, comparar con los reportados internacionalmente y con los especificados en la propia norma. Como conclusion se tiene la necesidad de eficientizar los sistemas de alumbrado, con tecnologia ahorradora, mejorar los niveles de iluminacion e igualar los indices energeticos de DPEA con los recomendados.

  8. Comparative analysis of the indexes of electric power density in buildings lighting systems; Analisis comparativo de los indices de densidad de potencia electrica de los sistemas de alumbrado en edificios

    Energy Technology Data Exchange (ETDEWEB)

    Cruz Hernandez, J I; Morillon Galvez, D [CONAE, Mexico, D. F. (Mexico)

    1996-12-31

    The national situation of the lighting systems in buildings is presented in order to know its consumption and make comparisons in accordance with the terms of the Electric Power Density that the lighting systems must satisfy, recently published in the norm, NOM 007 ENER-1995 (Energy Efficiency for non Residential Buildings` Lighting Systems). The form of application of the norm to determine the Electric Power Density Indexes in Lighting Buildings (EPDIL) is described, which permitted to know the current situation of the lighting systems, to compare the results internationally and with the ones specified in the proper norm. As a conclusion, there is the need of enhancing the efficiency of the lightning systems, with savings technologies, improve the lightning levels and equalize the energy indexes of the EPDIL with the ones recommended. [Espanol] Se presenta un estudio sobre la situacion nacional de los sistemas de alumbrado en edificios, con el objeto de conocer su consumo y compararlos, de acuerdo a los terminos de densidad de potencia electrica que deben cumplir los sistemas de alumbrado, publicados recientemente en la norma, NOM 007 ENER-1995 (Eficiencia Energetica para los Sistemas de Alumbrado en Edificios no Residenciales). Se describe la forma de aplicar la norma para determinar los indices de densidad de potencia electrica en alumbrado (DPEA) en edificios, lo cual permitio conocer la situacion actual de los sistemas de alumbrado, comparar con los reportados internacionalmente y con los especificados en la propia norma. Como conclusion se tiene la necesidad de eficientizar los sistemas de alumbrado, con tecnologia ahorradora, mejorar los niveles de iluminacion e igualar los indices energeticos de DPEA con los recomendados.

  9. Fractal analysis of the electrical discharges' surface paths in polymeric insulation considering different pollution levels; Analisis fractal de las trayectorias de descargas electricas superficiales en aislamiento polimerico considerando diferentes niveles de contaminacion

    Energy Technology Data Exchange (ETDEWEB)

    Palacios Lopez, Arturo

    2002-07-01

    In this thesis tree patterns of superficial breakdown in polymeric insulator of Silicon Rubber are generated. Experimental arrangement rod-rod was used on the basis of norm ASTM D 2303-85. Pollution levels on the basis of norm IEC 507 were also used. The experimental values of Fractal Dimension for each case of pollution were reported. A self similar method called Box Counting for the fractal dimension calculus and for the self affine methods an R/S and Variogram were used. According to the results, it was concluded that the tree patterns of superficial electric breakdown in Silicon Rubber is self similar and its value does not depend on the degree of pollution, that is equivalent to the concentration of salt for liter of water or to the Equivalent Salt Deposition (ESDD), in the surface of an insulator. [Spanish] En el presente trabajo se inducen descargas electricas superficiales en un aislamiento polimerico de Hule Silicon, el arreglo experimental que se utilice es punta-punta con base en la norma ASTM D 2303-85 y los niveles de contaminacion con base en la norma IEC 507. Se reportan los valores experimentales de la Dimension Fractal para cada caso de contaminacion, se utilice el metodo auto similar de conteo de cuadros, para el calculo de la Dimension Fractal y para metodos auto afines se utilice analisis R/S y variograma. Con los resultados obtenidos se concluye que la trayectoria de la descarga electrica superficial en un polimero de Hule Silicon es auto similar y su valor no depende del grado de contaminacion, el cual es equivalente a la concentracion de gramos de sal por litro de agua o a la densidad de sal depositada (DESD), en la superficie de un aislador.

  10. Homogeneous grouping of residential users of electric power in accordance with the variables that affect the consumption; Agrupamientos homogeneos de usuarios residenciales de energia electrica en funcion de las variables que impactan el consumo

    Energy Technology Data Exchange (ETDEWEB)

    Campero Littlewood, E.; Romero Cortes, J. [Departamento de Energia, Universidad Autonoma Metropolitana - Unidad Azcapotzalco, Mexico, D. F. (Mexico)

    1997-12-31

    This paper presents the results of the correlation analysis of the monthly consumption of electric power and the capacities in watts of the electric household appliances and domestic lighting performed in a sample of users of the residential tariff. To carry out this task, the information obtained in the answers to the inquiry applied to a group of dwellings, was used (the results of the inquiry are presented in another paper of this Seminar). The correlation variables were obtained from the nominal capacities or through the actual measurements of the energy consumption of the electric household appliances similar to the ones found in the visited homes. At the end of this paper the result of the application of the cluster analysis technic to obtain homogeneous groups of users, is presented, so as to be in position of estimating the shape of the hourly demand curve by means of the recording of the demand (watts) of a small sample of users. [Espanol] En este articulo se presenta el resultado de correlacion del consumo mensual de energia electrica y las capacidades en watts de los electrodomesticos e iluminacion realizado a una muestra de usuarios de tarifa residencial. Para este trabajo se utilizo la informacion obtenida en las respuestas de una encuesta aplicada en un conjunto habitacional (los resultados de la encuesta se presentan en otro articulo en este Seminario). Las variables de la correlacion se obtuvieron a partir de las especificaciones de capacidades o a traves de mediciones en electrodomesticos similares a los encontrados en los hogares. Al final se presenta el resultado de la aplicacion de la tecnica de formacion de agrupamientos `Cluster Analysis` para obtener grupos homogeneos de usuarios, de forma que se pueda estimar el perfil de demanda electrica mediante el registro de la demanda (watts) de una pequena muestra de usuarios.

  11. Homogeneous grouping of residential users of electric power in accordance with the variables that affect the consumption; Agrupamientos homogeneos de usuarios residenciales de energia electrica en funcion de las variables que impactan el consumo

    Energy Technology Data Exchange (ETDEWEB)

    Campero Littlewood, E; Romero Cortes, J [Departamento de Energia, Universidad Autonoma Metropolitana - Unidad Azcapotzalco, Mexico, D. F. (Mexico)

    1998-12-31

    This paper presents the results of the correlation analysis of the monthly consumption of electric power and the capacities in watts of the electric household appliances and domestic lighting performed in a sample of users of the residential tariff. To carry out this task, the information obtained in the answers to the inquiry applied to a group of dwellings, was used (the results of the inquiry are presented in another paper of this Seminar). The correlation variables were obtained from the nominal capacities or through the actual measurements of the energy consumption of the electric household appliances similar to the ones found in the visited homes. At the end of this paper the result of the application of the cluster analysis technic to obtain homogeneous groups of users, is presented, so as to be in position of estimating the shape of the hourly demand curve by means of the recording of the demand (watts) of a small sample of users. [Espanol] En este articulo se presenta el resultado de correlacion del consumo mensual de energia electrica y las capacidades en watts de los electrodomesticos e iluminacion realizado a una muestra de usuarios de tarifa residencial. Para este trabajo se utilizo la informacion obtenida en las respuestas de una encuesta aplicada en un conjunto habitacional (los resultados de la encuesta se presentan en otro articulo en este Seminario). Las variables de la correlacion se obtuvieron a partir de las especificaciones de capacidades o a traves de mediciones en electrodomesticos similares a los encontrados en los hogares. Al final se presenta el resultado de la aplicacion de la tecnica de formacion de agrupamientos `Cluster Analysis` para obtener grupos homogeneos de usuarios, de forma que se pueda estimar el perfil de demanda electrica mediante el registro de la demanda (watts) de una pequena muestra de usuarios.

  12. Automatic inspection of the main primary circuit piping at the south Ukraine nuclear power plant

    International Nuclear Information System (INIS)

    Tanarro, A.

    1995-01-01

    In response to GOSKOMATOM requests, the TPEG (from The Commission of the European Communities) undertook development of the general approach to the Project, or Terms of Reference, with a view to procuring complete financing of the project through TACIS funds. Subsequently UNESA (Unidad Electrica S.A.), as the organization responsible for the On-site Assistance Project for South Ukraine NPP, jointly reviewd the contents of the project with the plant and coordinated development throughout the initial phase, which finishes in May 1995. From the very start the definition of the Project covered all the Activities required to ensure its final objective: full autonomy for the Plant to perform inspections and the capacity required for this to be achieved to a suitable level of quality

  13. Development of a dose database in the refuelling scenario of a nuclear power plant for a virtual reality application

    International Nuclear Information System (INIS)

    Rodenas, J.; Zarza, I.; Pascual, A.; Felipe, A.; Sanchez-Mayoral, M.L.

    2002-01-01

    Operators in Nuclear Power Plants can receive high doses during refuelling operation. A training program simulating refuelling operations will be useful to reduce doses received by workers as well as to minimise operation time. With this goal in mind a Virtual Reality application is developed in the frame of CIPRES Project (Calculos Interactivos de Proteccion Radiologica en un Entorno de Simulacion - Interactive Calculations of Radiological Protection in a Simulation Environment), a RD project sponsored by IBERINCO and developed jointly by IBERINCO and the Nuclear Engineering Department of the Polytechnic University of Valencia. The Virtual Reality application requires the possibility of displaying doses, both instantaneous and accumulated, at all times during the operator training. Therefore, it is necessary to elaborate a database containing dose rates at every point of the refuelling plant. This database is elaborated from Radiological Protection Surveillance data measured throughout the plant during refuelling operation. To estimate doses throughout the refuelling plant some interpolation routines have been used. Different assumptions have been adopted in order to perform the interpolation and obtain consistent data. In this paper, procedures developed to elaborate the dose database for the Virtual Reality application are presented and analysed

  14. Alternative analysis to increase the power in combined-cycle power plants; Analisis de alternativas para el incremento de potencia en plantas termoelectricas de Ciclo Combinado

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco Cruz, Hector; Arriola Medellin, Alejandro M. [Gerencia de Procesos Termicos, Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)]. E-mail: hpacheco@iie.org.mx; aarriola@iie.org.mx

    2010-11-15

    The electricity industry traditionally had two thermodynamic cycles for power generation: conventional steam turbine (Rankine cycle) used to supply a base load during the day, and gas turbines (Brayton cycle), for its speed response, normally used to cover peak loads. However, to provide variable peak loads, the gas turbine, as a volumetric machine is affected by the change in air density by changing the combustion temperature. This paper shows the scheme of integration of both systems, that it's known as combined cycle and the different options that would have these power plants, to maintain or increase their power in variable ambient conditions. It analyzes different options, such as: 1. Supplementary fire in the stove. 2. Air cooling intake in the gas turbine (evaporation system or mechanical system). 3. Steam injection in the combustion chamber. [Spanish] La industria electrica tradicionalmente a contado con dos ciclos termodinamicos para generacion electrica: las turbinas convencionales de vapor (ciclo de Rankine) se utilizan para suministrar una carga base durante el dia, y las turbinas de gas (ciclo de Brayton), por su rapidez de respuesta, se utilizan normalmente para cubrir las cargas pico. Sin embargo, para suministrar las cargas variables pico, la turbina a gas, por ser una maquina volumetrica, se ve afectada por el cambio de la densidad del aire de combustion al cambiar la temperatura ambiente. En este trabajo se muestra el esquema de integracion de ambos sistemas, en lo que se conoce como ciclo combinado y las diferentes opciones que tendrian estas plantas de generacion electrica para mantener o incrementar su potencia en condiciones ambiente variable. Para ello se analizan diferentes opciones, tales como: 1.- Combustion suplementaria en el recuperador de calor. 2.- Enfriamiento del aire de admision a la turbina de gas (mediante un sistema de evaporacion o mediante un sistema mecanico). 3.- Inyeccion de vapor a la camara de combustion. Palabras

  15. Calculation of electromagnetic fields in electric machines by means of the finite element. Algorithms for the solution of problems with known total densities. Pt. 2; Calculo de campos electromagneticos en maquinas electricas mediante elemento finito. Algoritmos para la solucion de problemas con densidades totales conocidas. Pt. 2

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Mauricio F [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    This article is based in the electromagnetic modeling presented in the first part. Here are only considered the magnetic systems or electric systems in closed regions with moving or axial symmetry, whose total current density or total electric load density is known. The algorithms that have been implanted in the software CLIIE-2D of the Instituto de Investigaciones Electricas (IIE) are developed in order to obtain numerical solutions for these problems. The basic systems of algebraic equations are obtained by means of the application of the Galerkin method in the discreteness of the finite element with first order triangular elements. [Espanol] Este articulo se basa en la modelacion electromagnetica presentada en la primera parte. Aqui solo se consideran sistemas magneticos o sistemas electricos en regiones cerradas con simetria translacional o axial, cuya densidad de corriente total o densidad de carga electrica total es conocida. Se desarrollan los algoritmos que se han implantado en el programa de computo CLIIE-2D, del Instituto de Investigaciones Electricas (IIE) con el fin de obtener soluciones numericas para estos problemas. Los sistemas basicos de ecuaciones algebraicas se obtienen mediante la aplicacion del metodo de Galerkin en la discretizacion de elemento finito con elementos triangulares de primer orden.

  16. Calculation of electromagnetic fields in electric machines by means of the finite element. Algorithms for the solution of problems with known total densities. Pt. 2; Calculo de campos electromagneticos en maquinas electricas mediante elemento finito. Algoritmos para la solucion de problemas con densidades totales conocidas. Pt. 2

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Mauricio F. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    This article is based in the electromagnetic modeling presented in the first part. Here are only considered the magnetic systems or electric systems in closed regions with moving or axial symmetry, whose total current density or total electric load density is known. The algorithms that have been implanted in the software CLIIE-2D of the Instituto de Investigaciones Electricas (IIE) are developed in order to obtain numerical solutions for these problems. The basic systems of algebraic equations are obtained by means of the application of the Galerkin method in the discreteness of the finite element with first order triangular elements. [Espanol] Este articulo se basa en la modelacion electromagnetica presentada en la primera parte. Aqui solo se consideran sistemas magneticos o sistemas electricos en regiones cerradas con simetria translacional o axial, cuya densidad de corriente total o densidad de carga electrica total es conocida. Se desarrollan los algoritmos que se han implantado en el programa de computo CLIIE-2D, del Instituto de Investigaciones Electricas (IIE) con el fin de obtener soluciones numericas para estos problemas. Los sistemas basicos de ecuaciones algebraicas se obtienen mediante la aplicacion del metodo de Galerkin en la discretizacion de elemento finito con elementos triangulares de primer orden.

  17. Environmental management project of the Patache power plant project and associated transmission line; Gestion ambiental proyecto central termoelectrica Patache y linea de transmision asociada

    Energy Technology Data Exchange (ETDEWEB)

    Carreno Paredes, Cristian [Compania Electrica Tapaca (CELTA, S. A.), (Chile)

    1996-12-31

    This report makes a brief description of the services developed by INGENDESA of the projects executed in the area of engineering as well as in the area of environmental matters. In a second instance a relatively detailed presentation is made of the most important background of the Chilean project: {sup E}nvironmental Management of the Patache Power Plant and the Associated Transmission Line-Compania Electrica Tarapaca (CELTA, S.A.) Region I{sup .} The justification for the construction of the power plant and the environmental problems associated with the same are described [Espanol] En el presente informe se hace una breve presentacion de los servicios desarrollados por INGENDESA, de los proyectos elaborados tanto en el area de la ingenieria como en la tematica ambiental. En segunda instancia, se hace una presentacion relativamente detallada de los antecedentes mas importantes del proyecto chileno {sup G}estion Ambiental Central Patache y Linea de Transmision Asociada - Compania Electrica Tarapaca (CELTA, S.A.) I Region{sup .} Se describe la justificacion de la construccion de esta central termoelectrica y los problemas ambientales asociados a la misma

  18. Environmental management project of the Patache power plant project and associated transmission line; Gestion ambiental proyecto central termoelectrica Patache y linea de transmision asociada

    Energy Technology Data Exchange (ETDEWEB)

    Carreno Paredes, Cristian [Compania Electrica Tapaca (CELTA, S. A.), (Chile)

    1997-12-31

    This report makes a brief description of the services developed by INGENDESA of the projects executed in the area of engineering as well as in the area of environmental matters. In a second instance a relatively detailed presentation is made of the most important background of the Chilean project: {sup E}nvironmental Management of the Patache Power Plant and the Associated Transmission Line-Compania Electrica Tarapaca (CELTA, S.A.) Region I{sup .} The justification for the construction of the power plant and the environmental problems associated with the same are described [Espanol] En el presente informe se hace una breve presentacion de los servicios desarrollados por INGENDESA, de los proyectos elaborados tanto en el area de la ingenieria como en la tematica ambiental. En segunda instancia, se hace una presentacion relativamente detallada de los antecedentes mas importantes del proyecto chileno {sup G}estion Ambiental Central Patache y Linea de Transmision Asociada - Compania Electrica Tarapaca (CELTA, S.A.) I Region{sup .} Se describe la justificacion de la construccion de esta central termoelectrica y los problemas ambientales asociados a la misma

  19. Predictive analysis on the electric energy distribution systems reliability: applying the synerGEE system; Analisis predictivo de la confiabilidad en los sistemas de distribucion de energia electrica: aplicando el sistema synerGEE

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Andrade, Carlos

    2008-12-15

    Electrical distribution systems ought to deliver electric power as economical as possible with an acceptable degree of service quality and continuity. Nevertheless, their faults represent one of the main causes of customer's unavailability. At the moment, a wide range of determinist criteria in the improvement of systems reliability based on past behavior are used, but they do not respond to the stochastic nature of system behavior, and are applied without an adequate balance between reliability and economy. In order to obtain this balance a minimum cost planning methodology that considers the predictive analysis of different investment alternatives in addition to the past behavior of the system is required, which guarantees that the economic resource available and limited will be used to gather the greater possible reliability degree. In this work this problem is approached with the fundamentals and methodologies needed to assess the design effects and operative criteria over the main reliability indexes used by the main utilities around the world, with emphasis on the need to optimize economical resources. The use of the system SynerGEETM, is investigated, probing it as a useful tool for the predictive reliability analysis. Due to the lack of experience that exists in Mexico with this type of analysis, distribution engineers has to become familiar with the concepts of the reliability engineering, their application to establish distribution systems models, and acquiring the ability to use the modern simulation tools, allowing them to evaluate the behavior of these systems with enough analytical rigor. In this sense a serial of well known study cases are presented to help them in this labor. [Spanish] Los sistemas de distribucion de energia electrica deben satisfacer la demanda de energia electrica de la forma mas economica posible, con un grado de calidad y continuidad aceptable. Sin embargo, sus fallas son una de las principales causas de indisponibilidad en

  20. Design and construction of the prototype of a digital meter of single phase electric energy based in a microcontroller; Diseno y construccion del prototipo de un medidor digital de energia electrica monofasico basado en un microcontrolador

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Alonso, Ruben

    2003-10-15

    This research work presents the design and construction of a single-phase microcontroller-based digital electric energy meter. The digital instrument displays the energy demand (kw-h) based on up-to-date tariff provided by the Mexican national utility Comision Federal de Electricidad (CFE). The meter digitally processes voltage and current line waveform samples taken at its input, displaying, in real time, the number of electrical parameters calculated. For a better instrument performance a PIC16F874 microcontroller from microchip has been used as computational core. The parameters of interest are visualized in a liquid crystal display of 2 X 16 characters. The user interface includes a menu where some of the parameters can be selected by the operator. In the event of an electric power supply disruption the meter keeps to the energy consumption in memory. The voltage and current measured levels ranges from 1 to 255 Vrms and 0.1 to 25.5 Arms, respectively. The power is displayed in 5 digits ranging from 0 to 6502.5 watts and the energy is displayed with 5 whole digits and 5 decimals ranging, from 0 kWh up to 99999.99999 kWh. These values are refreshed every one second together with the actual electrical consumption cost which ranges from 0 up to 9999.9 pesos. The digital measuring instrument has been built based on four main inter-connected modules named, data acquisition; signal conditioning; signal processing; and display. A set of efficient assembly code routines has been developed in order to calculate the number of electrical parameter previously described. After a debugging process, the optimised code has been assembled for the PIC16F874. [Spanish] El trabajo presenta el diseno y construccion de un medidor digital de energia electrica basado en un microcontrolador, el cual visualiza la demanda por el consumo de kWh, basandose en una tarifa escalonada de tipo domestico de CFE. Tambien el aparato visualiza voltaje, corriente, potencia y el tiempo de medicion

  1. Procedures to enter the international market of the carbon and PEMEX electrical generation projects; Procedimientos para ingresar al mercado internacional del carbono y proyectos de generacion electrica de PEMEX

    Energy Technology Data Exchange (ETDEWEB)

    Zeferino Abundis, Yolanda [Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D.F. (Mexico)

    2006-11-15

    The consumption and production of the electrical energy contribute to the gas emission that has the property of retaining heat in the atmosphere, giving rise to an increment in the global average temperature of the Earth, and causing a climatic change that the international scientific consensus describes as important alterations in the meteorological patterns. As a result of this, international actions were taken. The most ambitious agreement and by its quantified and obligatory character is presented the Kyoto Protocol, that forces the countries listed in Annex 1 to reduce their emissions through national measures and flexible mechanisms, within these last ones is the Clean Development Mechanism (CDM) that contemplates the mutual cooperation between developed and developing countries in the participation of projects tending to the reduction of gas emissions of greenhouse effect. Petroleos Mexicanos (PEMEX) has large necessities of electrical energy and steam, and counts on projects with characteristics that under the CDM cover the characteristics to be technical and economically viable. [Spanish] El consumo y produccion de la energia electrica contribuye a la emision de gases que tienen la propiedad de retener calor en la atmosfera, dando lugar a un incremento en la temperatura promedio global de la Tierra, y provocando un cambio climatico que el consenso cientifico internacional describe como alteraciones importantes en los patrones meteorologicos. A raiz de esto, se tomaron acciones internacionales. El acuerdo mas ambicioso y por su caracter cuantificado y obligatorio lo representa el Protocolo de Kyoto, quien obliga a los paises listados en el Anexo 1 a reducir sus emisiones a traves de medidas nacionales y mecanismos flexibles, dentro de estos ultimos se encuentra el Mecanismo de Desarrollo Limpio (MDL) que contempla la cooperacion mutua entre paises desarrollados y en vias de desarrollo en la participacion de proyectos tendientes a la reduccion de emisiones

  2. Influencia de la generación distribuida en los niveles de cortocircuito y en las protecciones eléctricas en subestaciones de 110 / 34,5 kV; The effects caused due to the introduction of Distribution Generation in the short-circuit levels and the protecti

    Directory of Open Access Journals (Sweden)

    Marta Bravo de las Casas

    2011-02-01

    Full Text Available En este trabajo se muestran algunos resultados de los efectos provocados por la introducción de la GD enlas redes cubanas en lo que respecta a los niveles de cortocircuito y los ajustes de las protecciones en cincosubestaciones de 110 / 34,5 kV ubicadas en las provincias de Villa Clara, Cienfuegos y Sancti Spíritus. Seobtuvieron conclusiones importantes con respecto a las necesidades de funciones de protección y criteriosde ajuste de las protecciones. Además, con respecto a la necesidad de tener en las subestaciones relésdigitales modernos con el fin de que puedan responder correctamente y en el menor tiempo posible a losdiferentes escenarios de operación que tendrá el sistema en las nuevas condiciones y así corresponder a lasexigencias que impone la GD a los esquemas de protección. In this article, results are shown of the effects caused due to the introduction of Distribution Generation(DG in the Cuban Networks with respect to short-circuit levels and the protection settings of five 110/34.5kV substations located in the provinces of Villa Clara, Cienfuegos y Sancti Spíritus. Important conclusionshave been obtained with respect to the necessities of the protection functions and their settings criteria.Besides, with respect to the necessity of having modern digital relays in order to respond correctly and inthe least possible time to the different stages of operation that the system may have in the new conditionsof operation and in this manner corresponds to the demands that the DG imply in protection systems. 

  3. Electric power saving in the drinkable water, sewage and sanitation system, La Piedad; Ahorro de energia electrica en el sistema de agua potable, alcantarillado y saneamiento de La Piedad

    Energy Technology Data Exchange (ETDEWEB)

    Sistema de Agua Potable, Alcantarillado y Saneamiento de la Piedad (Mexico). E-mail: sapaslapiedad@prodigy.net.mx

    2006-04-15

    In Michoacan, Mexico, a project who seeks to benefice the Municipal public resources was crated in 1994. It would be achieved trough the electric power saving in the public lighting system, and drinkable water pumping and black water, since those activities required the budget biggest part. The program could be developed recently and the saving was significant. In addition the electromechanical efficiency increased in the equipment installation. This work is an example for other States to do something similar that can improve their conditions. [Spanish] En el estado de Michoacan, Mexico se creo un proyecto en el ano de 1994, el cual buscaba beneficiar los recursos publicos municipales, a traves del ahorro de la energia electrica en los sistemas de alumbrado publico y bombeo de agua potable y aguas negras, ya que estas actividades son las que requieren la mayor parte del presupuesto. El programa pudo llevarse a cabo en anos recientes y el ahorro fue significativo, ademas de que aumento la eficiencia electromecanica en los equipos que se instalaron, y esta obra ha servido de ejemplo a otros estados para que realicen algo similar que pueda mejorar su situacion.

  4. New technologies, virtual reality and multimedia, in Radiation Protection training; Nuevas tecnologias, realidad virtual y multimedia, aplicadaas a la formacion en proteccion radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Felipe, A.; Sanchez-Mayoral, M. L.; Lamela, B.; Merino, A.; Sarti, F.

    2003-07-01

    Iberdrola Ingenieria y Consultoria (Iberinco) has developed some computer applications based in New Technologies, Virtual Reality and Multimedia, with the aim to optimise the formation and training of professionally exposed workers as well as to inform the public. The use of the new technologies could be an important help for the workers training. Virtual Reality Projects developed by Iberinco are: a) CIPRES: Interactive Calculations of Radiological Protection in a Simulation Environmental and, b) ACEWO: Workers Control Access to Nuclear Power Plants, virtual Reality could be directly applicable to several aspects related with Radiological Protection Training, for example. An application that workers could used to learn the main aspects of Radiological Protection related with: a) Physical concepts, b) Regulations, c) Use of protective clothing, d) Access into and exit out controlled areas, e) ALARA criterion. An examples is the project ACEWO. A training program based on Virtual Reality systems with simulations of procedures in which the operators could receive high doses. In this way, the operation time and dose could be minimised according to the ALARA criterion owing to the ability of repeating the exercise, or the work, as many times as be necessary, like project CIPRES. Iberinco has been developed an educational CD multimedia on nuclear energy and the protection measures foreseen in the emergency plans for the Spanish Civil Protection Agency, with the aim of being distributed to all the schools placed near a nuclear power plant. (Author) 4 refs.

  5. 9RU2 Radiological protection, attention to the detail-EPU; 9RU2 Proteccion radiologica, atencion al detalle-EPU

    Energy Technology Data Exchange (ETDEWEB)

    Padilla C, I. [CFE, Central Laguna Verde, Km. 42.5 Carretera Cardel-Nautla, Veracruz (Mexico)]. e-mail: ipadilla@cfe.gob.mx

    2008-07-01

    To optimize times and movements in a reload project of nuclear fuel in a nuclear plant, where they are programmed more three thousand maintenance activities, modifications, monitoring and inspection in a smaller period to 30 days, and additionally to optimize the individual and collective dose in the same one, turn out to be important challenges where the used strategies must be accompanied of a deep knowledge of the installation in the radiological sense and of the spaces conceptualized in the time. The attention to the detail makes possible that the objectives are fulfilled. During the shutdown of reload 9 of Unit 2 (9RU2) of the nuclear power plant of Laguna Verde, the attention in detail applied in the critical points allowed a saving of dose of 0.7 Sv-person and one deviation of the goal of only +0.85% (smaller to 1% of the goal established like 2 challenge of Sv-person). Analysis of times, movements and training to develop skills in inspection activities in service that requires intervention in the external surface of the reactor vessel to examine the condition of welds, allowed reducing times of execution of 12 to 2 hours. Analysis of the environment and attention to the detail are techniques that allowed optimizing dose in 9RU2 and they were used in the project Power Increase. In this work the strategies of the surroundings and attention in detail applied in 9RU2 would appear and detail attention in the increase of power in the reload 13 Unit 1. (Author)

  6. Questions to the reactors power upgrade of the Nuclear Power Plant of Laguna Verde

    International Nuclear Information System (INIS)

    Salas M, B.

    2014-08-01

    The two reactors of the Nuclear Power Plant of Laguna Verde (NPP-L V) were subjected to power upgrade labors with the purpose of achieving 20% upgrade on the original power; these labors concluded in August 24, 2010 for the Reactor 1 and in January 16, 2011 for the Reactor 2, however in January of 2014, the NNP-L V has not received by part of the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) the new Operation License to be able to work with the new power, because it does not fulfill all the necessary requirements of safety. In this work is presented and analyzed the information obtained in this respect, with data provided by the Instituto Federal de Acceso a la Informacion Publica y Proteccion de Datos (IFAI) and the Comision Federal de Electricidad (CFE) in Mexico, as well as the opinion of some workers of the NPP-L V. The Governing Board of the CFE announcement that will give special continuation to the behavior on the operation and reliability of the NPP-L V, because the frequency of not announced interruptions was increased 7 times more in the last three years. (Author)

  7. Criteria for the provision and assembly of the rotor blades of a 300 MW low pressure steam turbine for electrical generation; Criterios para el suministro y ensambles de la alabes de rotor de turbina de vapor de 300 MW baja presion para generacion electrica

    Energy Technology Data Exchange (ETDEWEB)

    Bertin, Galo; Felix, Jorge A; Quijano, Octavio [Especialistas en Turbopartes, S.A. de C.V., Queretaro, Queretaro (Mexico)

    2007-11-15

    This paper presents some of the main criteria to consider from the inspection, disassembling and assembly of blades with different root types of a turbine rotor of steam turbines for power generation, having as an aim to count on a reliable rotor, fulfilling with the equipment original design and norms and international standards. [Spanish] Este trabajo presenta algunos de los criterios principales a considerar desde la inspeccion, desmontaje y montaje de alabes de diferentes tipos de raiz de un rotor de turbinas de vapor de generacion electrica, teniendo como finalidad contar con un rotor confiable, cumpliendo con el diseno original del equipo y con normas y estandares internacionales.

  8. Impact of a PV system interconnected to the electric network of a High Consumption Domestic user's demand in BCS; Impacto de un sistema fotovoltaico interconectado a red en la demanda electrica de un usuario DAC en BCS

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez Grajales, H. R.; Agredano Diaz, Jaime; Gonzalez Galarza, R.; Munguia del Rio, G. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2010-11-15

    In Mexico, the incident solar radiation is high enough, that encourage its use both to produce process heat or electricity trough solar cells in autonomous configurations or grid. In European countries with substantially lower irradiation levels such as Germany or Spain. PV Grid Connected Systems (PVGCS) are a mature technology that is widely used in these countries, mainly due to tax incentives and preferential feed in tariffs schemes. Of the benefits that electricity production modality provides both the user and to the electricity grid and also the technical benefits for the utilities for incorporating distributed generation at its distribution system. In Mexico, more and more people are motivated to invest in this type of technology. This article analyzes the particular case of a user that is classified as High Consumption Domestic Customer (HCDC) in the city of La Paz, Baja California Sur, Mexico, who owns a single phase of 6 kWp PVGCS installed on the roof of her house. The reported results in this paper come from data analyzed by the Electrical Research Institute (IIE) for a three year monitoring period. The paper includes meteorological information, energy and power balances, maximum power, standard production, system losses, efficiency of the photovoltaic generator and inverters, among other performance information. The document highlights the impact that the PV system on electricity consumption user billing from the utility, and some recommendations are provided on what must be done in order get out from the HCDC classification and the economic benefits of it. [Spanish] En Mexico se tienen niveles de irradiacion solar suficientemente altos que desde un punto de vista puramente energetico alientan a su aprovechamiento en la produccion de electricidad, ello mediante sistemas fotovoltaicos directamente conectados a la red electrica convencional (SFVI). En paises europeos con niveles de irradiacion sustancialmente inferiores - i.e. Espana o Alemania- esta

  9. A new cascaded hydropower plants in El Sheikh Zayed Canal in the new valley in Egypt

    Energy Technology Data Exchange (ETDEWEB)

    Hosny Fahmy, Faten [Electronics Research Institute, Cairo (Egypt)

    2000-07-01

    With the streaks of the light looming in the horizon, heralding the dawn of the 21st century and the closing of the 20th century, the whole people of the world specially the sons of Egypt are full of hopes and dreams. The south Egypt development project is translation of this concept viewed from comprehensive strategic vision embracing a number of development fields covering activities in the field of agriculture, industry, transport, communication and roads as well as social aspects services such as health and education that would drive Egypt to the horizons of the 21st century. This new projects are: Toshka, New Valley or New Delta, Sheik Zayed which will feed more than a million feddans, transforming the desert into a green carpet, turning the wheels of industries and shedding off the stiffing nightmare of the choking narrow valley. This paper presents a new idea and application to know to use the water flow from the Nasser lake after raising and pumping with certain speed according to the ground slope. A series of hydro power plants are designed on certain interested points on El Sheikh Zayed Canal to generate electrical energy which will be required to feed several projects in this new valley. The results show the comparison between these eight hydro power plants w.r.t: it's generated electrical energy water release, water contents and the head of water inside each one. Also, the study contains the mathematical models of each hydropower station and the mathematical description of each reservoir, barrages and power stations. [Spanish] Con los rayos de luz asomandose en el horizonte, anunciando el amanecer del siglo XXI y el ocaso del siglo XX, todas las personas del mundo, especialmente los hijos de Egipto, estan llenos de suenos y esperanza. El proyecto de desarrollo del sur de Egipto traduce este concepto desde una vision estrategica integral que incluye un gran numero de areas de desarrollo que abarcan actividades en el campo de la agricultura, la

  10. Energy saving in the pumping of drinking water, Municipality of San Felipe, Guanajuato; Ahorro de energia electrica en bombeo de agua potable, en el municipio de San Felipe, Gto.

    Energy Technology Data Exchange (ETDEWEB)

    Gamiz Sanchez, Lorenzo [Applied Technology Center de Mexico, S.A. de C.V. (Mexico)

    2006-01-15

    This paper shows the results attained in energy saving through a project of potable water pumping, which took an investment of $433,043.00 and an internal rate of return of 126%. This project puts into evidence that it is possible to reduce between 15 and 30% of the total invoicing for energy consumption in potable water pumping if an equipment of poor efficiency is replaced by another of high efficiency. The project was requested by the Guanajuato's State Water Comision and the Municipal Bureau of Sewage and Potable Water, with the double intention of reducing the energy consumption along with the corresponding invoicing and incrementing the output of the wells in order to improve the potable water supply. In the site two high efficiency submersible motor-pumps were installed previously to the energy diagnosis that triggered profitable operation results and a convenient invoicing. [Spanish] Se documentan los resultados obtenidos en un proyecto de ahorro de energia en el bombeo de agua potable realizado con una inversion de $433,043.00 y con una tasa interna de retorno de 126%. Este proyecto pone en evidencia que es posible reducir entre el 15 y 30% de la facturacion total por consumo de energia electrica en el bombeo de agua potable si se sustituye un equipo poco eficiente por otro de alta eficiencia. El proyecto fue solicitado por la Comision Estatal del Agua de Guanajuato y la Junta Municipal de Agua Potable y Alcantarillado del municipio, con un doble proposito, reducir el consumo de energia junto con la facturacion correspondiente e incrementar la capacidad de produccion de los pozos con la intencion de mejorar el abasto de agua potable. En el lugar se instalaron dos motobombas sumergibles de alta eficiencia previo diagnostico energetico que desencadenaron rentables resultados operativos y de facturacion.

  11. Environmental management in Chile: The power plants case; Gestion ambiental en Chile: Caso de las centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Jadrijevic, Maritza [Comision Nacional del Medio Ambiente, (Chile)

    1996-12-31

    In this paper are presented the general aspects of the historic evolution o the legal norms on environmental matters in Chile; general aspects of the electric generation system and the instruments of environmental management currently applied in the fossil fueled power plants, such as: the assessment system of the environmental impact; compliance of the air quality and emissions Standards and plans for decontamination [Espanol] En este trabajo se dan a conocer aspectos generales de la evolucion historica de las normas juridicas en materia ambiental en Chile; aspectos generales del sistema de generacion electrica y los instrumentos de gestion ambiental que actualmente se aplican a las plantas de generacion termoelectricas, tales como: el sistema de evaluacion de impacto ambiental; cumplimiento de normas de la calidad de aire y de emision y, planes de descontaminacion

  12. Environmental management in Chile: The power plants case; Gestion ambiental en Chile: Caso de las centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Jadrijevic, Maritza [Comision Nacional del Medio Ambiente, (Chile)

    1997-12-31

    In this paper are presented the general aspects of the historic evolution o the legal norms on environmental matters in Chile; general aspects of the electric generation system and the instruments of environmental management currently applied in the fossil fueled power plants, such as: the assessment system of the environmental impact; compliance of the air quality and emissions Standards and plans for decontamination [Espanol] En este trabajo se dan a conocer aspectos generales de la evolucion historica de las normas juridicas en materia ambiental en Chile; aspectos generales del sistema de generacion electrica y los instrumentos de gestion ambiental que actualmente se aplican a las plantas de generacion termoelectricas, tales como: el sistema de evaluacion de impacto ambiental; cumplimiento de normas de la calidad de aire y de emision y, planes de descontaminacion

  13. Nuclear power generation in competition with other sources for base load electricity generation; La generacion nuclear en competencia con otras fuentes para generacion electrica de base

    Energy Technology Data Exchange (ETDEWEB)

    Notari, C; Rey, F C [Comision Nacional de Energia Atomica, San Martin (Argentina). Unidad de Actividad Reactores y Centrales Nucleares

    1997-12-31

    The latest studies performed by OECD and IAEA on the subject were analyzed in order to clarify the international context. Nuclear, gas and coal are compared. The general conclusion is that nuclear power is competitive for electricity generation considering new plants to be commissioned around year 2000. If the discount rate is 5% per annum it is considered the best option in most of the countries included in the studies. If 10% is chosen the levelized costs favour the gas option. In the Argentine case, the analysis of possible plants for the near future shows a clear advantage for the gas projects. This is mainly due to the low capital costs and low local gas prices. The possible evolution of this situation is considered: gas prices will most probably increase because they should approach the price of fuel oil or diesel oil which are used as substitutes in winter for electricity generation and the export projects to Chile and Brasil will also push prices up. The environmental aspects of the question and its influence on regulations and costs is a matter of speculation. Some countries have already penalized greenhouse gases emissions but it is not clear how and when this trend will affect local prices. (author). 4 refs., 6 tabs.

  14. Starting of the steam generator of a fossil fuel power plant, using predictive control based in a neuronal model; Arranque del generador de vapor de una central termoelectrica, usando control predictivo basado en un modelo neuronal

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo Dominguez, Tonatiuh

    2004-09-15

    In this thesis work it is presented the design and implementation of a simulator of total scope of a predictive controller based in the neuronal model of the temperature in two stages of the heating of the steam generator of a fossil fuel power plant. An implemented control scheme is detailed, as well as the methodology for the identification of a neuronal model utilized for the control. Finally the results of the implementation in the simulator located at the Instituto de Investigaciones Electricas (IIE) are shown to be satisfactory. This control structure is not applied directly in closed circuit, but provides the value of the control actions to a human operator. [Spanish] En este trabajo de tesis se presenta el diseno e implementacion, en un simulador de alcance total, de un controlador predictivo basado en un modelo neuronal para el control de la temperatura en dos etapas del calentamiento del generador de vapor de una central termoelectrica. Se detalla el esquema de control implementado, asi como la metodologia de identificacion de un modelo neuronal utilizado para la sintesis del control. Finalmente se muestran los resultados de la implementacion en el simulador que se encuentra en el Instituto de Investigaciones Electricas (IIE); dichos resultados fueron satisfactorios. Esta estructura de control no se aplica directamente en lazo cerrado, sino que provee el valor de las acciones de control a un operador humano.

  15. Analysis of the participation of nuclear energy in electricity planning in Mexico; Analisis de la participacion de la energia nuclear en la planeacion electrica en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez H, U. A.; Martin del C, C., E-mail: uahh_123@hotmail.com [UNAM, Facultad de Ingenieria, Ciudad Universitaria, Circuito Exterior s/n, 04510 Ciudad de Mexico (Mexico)

    2017-09-15

    In recent years there has been an effort in Mexico and the world to reduce greenhouse gas emissions (GGE) and at the same time supply the increase in energy consumption worldwide. In this context, the electricity sector in Mexico is fundamental in the fulfillment of GGE reduction commitments and goals by contributing more than 20% of these. Nuclear energy must have a fundamental role in the expansion of the National Electric System, since it allows generating large amounts of electricity for long periods of time without emissions of polluting gases. With this background, was determined to investigate the main characteristics that nuclear technology must have in order to be considered as a real solution in guaranteeing the supply of electricity in a continuous, safe and economic manner with the least amount of GGE possible. However, combined cycle power plants are the main option to cover these needs in accordance with the current national policy, so in this work an extensive technical, economic and safety comparison between the combined cycle and nuclear technologies was carried out. In order to know the technology that should have a greater participation in the planning of the National Electric System in the coming decades. Thus, five price scenarios were elaborated for natural gas and liquefied natural gas imports, in order to know the cost that would generate to continue with the current policy of use of combined cycle power plants as a base for electricity generation and if that cost justified in the first instance the increase of nuclear capacity in the country. The results showed that is necessary to change the main source of power generation in Mexico in order to have a reliable, safe, economical and clean electrical system. (Author)

  16. Calculation of the electromagnetic fields in electric machines through the use of the finite element. Algorithms for the solution of induction problems. Pt. 3; Calculo de campos electromagneticos en maquinas electricas mediante elemento finito. Algoritmos para la solucion de problemas de induccion. Pt. 3

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Mario F [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    This article is based in the electromagnetic modeling presented in the first part of the series for the indirect solution of partial differential equations. Magnetic systems in closed regions with moving or axial symmetry, whose total current density is partially known (induction problems) are considered. Includes the ability to deal with means in movement and a sinusoidal behavior for the source density current is assumed. Some algorithms are developed that are implanted in the software CALIIE-2D of the Instituto de Investigaciones Electricas (IIE) to obtain the numerical solutions of these problems. The basic systems of algebraic equations are obtained through the application of the Galerkin method in the discreteness of the finite element with first order triangular elements. [Espanol] Este articulo se basa en la modelacion electromagnetica presentada en la primera parte de la serie y en el planteamiento proporcionado en la segunda parte para la solucion indirecta de ecuaciones diferenciales parciales. Se consideran sistemas magneticos en regiones cerradas con simetria traslacional o axial, cuya densidad de corriente total es parcialmente conocida (problemas de induccion). Incluye la capacidad para tratar medios con movimiento y se supone un comportamiento senoidal para la densidad de corriente fuente. Se desarrollan los algoritmos que se implantan en el programa de computo CALIIE-2D del Instituto de Investigaciones Electricas (IIE) para obtener las soluciones numericas de estos problemas. Los sistemas basicos de ecuaciones algebraicas se obtienen mediante la aplicacion del metodo de Galerkin en la discretizacion de elemento finito con elementos triangulares de primer orden.

  17. Development of a prototype of a Master Central Unit (MCU) for the automation of Distribution Control Centers; Desarrollo de un prototipo de Unidad Central Maestra (UCM) para la automatizacion de Centros de Control de Distribucion

    Energy Technology Data Exchange (ETDEWEB)

    Uribe Blanco, Carlos Eduardo; Mata Almanza, Rafael; Picasso Blanquel, Cuitlahuac [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2011-07-01

    For the purpose of contributing to the strategic plan and to the improvement of productivity and competitiveness levels, the Federal Electric Commission (CFE, Spanish acronym) is making a significant investment in human resources and materials to modernize electric energy supply systems, including monitoring, protection and automatic control for operating all the elements of the electrical process, from generating plants to transmission lines, distribution systems and commercial applications. With this modernization, the CFE is also creating the infrastructure for the interoperability and interconnectivity of the above systems, in such a way to enable it to broaden, continue and complement the functional integration of the linked institutional systems of the latest generation. The total integration of the systems will allow the CFE to move toward Intelligent Electric Networks. Therefore, the CFE requested help from the Electric Research Institute (IIE, Spanish acronym) to develop part of the infrastructure to modernize the automation of distribution. This consists of the development of a prototype of the supervision and control system, using interoperable open technology owned by the CFE which enables using the functions of a SCADA system (Supervisory Control And Data Acquisition) to supervise and control electric distribution networks. [Spanish] Con el proposito de contribuir al plan estrategico y mejoramiento de los niveles de productividad y competitividad, la Comision Federal de Electricidad (CFE) esta invirtiendo fuertemente en recursos humanos y materiales para la modernizacion de los sistemas de suministro de energia electrica, incluyendo el monitoreo, proteccion y control automatico para la operacion de todos los elementos del proceso electrico, desde los centros de generacion hasta las lineas de transmision, los sistemas de distribucion y las aplicaciones de comercializacion. Con dicha modernizacion, la CFE tambien esta generando la infraestructura para la

  18. Nissan Mexicana. First place in national prize of electrical energy saving 1998; Nissan Mexicana. Primer lugar en premio nacional de ahorro de energia electrica 1998

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez S, Enrique [Nissan Mexicana, S.A. de C.V., Planta Civac, Cuernavaca, Mor. (Mexico)

    1999-07-01

    For Plant CIVAC of Nissan Mexicana, the energy saving began in the year of 1990. From then, different programs have been developed using different strategies for energy saving until arriving at the Benchmarking with other Plants of Japan, which represents a new challenge, since it opened up an area of opportunity of saving in processes that generally were known in detail as far as to its main function (to make vehicles with quality, cost and opportunity of delivery), but the parameter of energy consumption of by unit and its benefits in relation to the cost was unknown. This was endorsed by the high Direction and began with the optimization of training for the operation of each equipment with the involvement of the user (Production), the engineering area (that establishes the process) and the maintenance area. We designed a general program where the basic activities were included, such as the general and special activities. Each one of them fulfilled its objective, but the special activities took us to the optimization of the processes, finding excess of energy in the design conditions. [Spanish] Para Planta CIVAC de Nissan Mexicana, el ahorro de energia se inicio en el ano de 1990. A partir de entonces se han desarrollado programas de ahorro de energia usando estrategias diferentes hasta llegar al Benchmarking con otras Plantas de Japon, el cual representa un reto nuevo, ya que puso al descubierto una area de oportunidad de ahorro en los procesos que por lo general se conocian a detalle en cuanto a la funcion principal (hacer vehiculos con calidad, costo y oportunidad de entrega), pero se desconocia el parametro de consumo de energia por unidad y sus beneficios en relacion con el costo. Esto fue avalado por la alta Direccion y se inicio con la capacitacion de la optimizacion de la operacion de cada equipo y se involucro al usuario (Produccion), al area de ingenieria (que establece el proceso) y al area de mantenimiento. Elaboramos un programa general donde se

  19. Possible transfer of traditional energy intensive industries towards developing countries. Offers of energy resource in the CIER [Comision de Integracion Electrica Regional] area in relation to this transfer

    International Nuclear Information System (INIS)

    Facchini Ferro, A.; D'Amado Campo, R.

    1989-01-01

    Due to the steep rise in oil prices in the early 1970s, South American countries became aware of the advisability of developing their abundant and renewable hydroelectric resources. The second energy crisis of 1979 pushed up oil prices still further and the consequences in the South American electricity sector included contractions in markets, overcapacity, and difficult financial circumstances. Increases in exports were seen as a way to reduce the burden of those countries' heavy debts and to improve economic conditions. To harmonize the interests of development of highly energy intensive industries in developed countries and the economic development of developing countries, the possibility of marketing energy as an industrial input should be considered. Evidence of the advantages that South American countries can offer to such industrial transfers is presented. These countries offer a source of plentiful hydropower from installations in operation, under construction, or projected as major developments. These installations are already largely interconnected through high- and extra-high-voltage power transmission networks. Technical information is given on the installed generating capacities, including thermal reserve plants; utilization levels; transmission line interconnections; and remaining renewable and non-renewable energy resources. Considerations regarding the political and financial implications of industrial transfers are discussed. 6 refs., 9 figs

  20. Application of an evolutionary algorithm in the reactive compensation of transmission networks of electrical energy planning; Aplicacion de un algoritmo evolutivo en la planificacion de la compensacion reactiva de redes de transmision de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Galicia, Julio A.; Nieva Gomez, Rolando [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    2001-07-01

    In the present work it is considered the mathematical formulation of the problem of the reactive compensation planning, The solution technique based on evolutionary programming is described and the results of compensation in the Northwest subsystem of the Mexican electrical system are shown. A technique of optimization based on the Evolutionary Programming is proposed to solve the problem of the Planning of the Reactive Compensation in transmission of electrical energy networks. The problem consists in determining how much compensation to add and where to locate it in such a way that the investment cost of the compensation equipment is diminished, plus the operation costs associated to the transmission losses, plus a penalty function associated to the violations of the operative limits of voltage. The compensation that is determined must allow that the network operates in normal conditions before any contingency of a pre-established assembly. The problem considered is non-linear and whole compound. Tests made to a representative system of the Northwest area of the Mexican electrical system of 171 nodes and 284 branches are reported. [Spanish] En el presente trabajo se plantea la formulacion matematica del problema de planificacion de la compensacion reactiva, se describe la tecnica de solucion basada en programacion evolutiva y se muestra resultados de compensacion en el subsistema Noroeste del sistema electrico mexicano. Se propone una tecnica de optimizacion basada en la Programacion Evolutiva para resolver el problema de la Planificacion de la Compensacion Reactiva en redes de transmision de energia electrica. El problema consiste en determinar cuanta compensacion agregar y donde ubicarla de tal manera que se minimice el costo de inversion del equipo de compensacion, mas los costos de operacion asociados a las perdidas de transmision, mas una funcion de penalizacion asociada a la violaciones de los limites operativos de voltaje. La compensacion que se determine

  1. Speed control and generation of electric power of a gas turbine by means of fuzzy-logic; Control de velocidad y de generacion de potencia electrica de una turbina de gas mediante logica difusa

    Energy Technology Data Exchange (ETDEWEB)

    Bahamaca Fernandez, Luis Jonathan

    2000-08-01

    The development of a fuzzy-logic control algorithm is presented. It was developed for the speed and load control of a gas turbine. The speed/load controller of the gas turbine which were conventional Pi's were completely replaced by the fuzzy-logic controllers. The fuzzy controllers correspond to MISO systems that has as input the error an its rate of change and as an output the control signal for the fuel valve. The fuzzy controller provides an algorithm that can turn a strategy of linguistic control (based on knowledge of experts) into a strategy of automatic control. The fuzzy controllers were validated by the development of functional test in a simulation of a nonlinear mathematical gas-turbine model. The controllers were programmed in C language in PC. Simulation test for the speed regulation and load tracking were used for the controller validation. The fuzzy controller had a good performance because the minimized the signal error produced by the set of programmed system perturbations (due to control actions). Besides, they had a better reference tracking then PI controllers. Consequently, the proposed fuzzy controllers have a better performance than the conventional control system. [Spanish] En este trabajo de tesis se presenta el diseno, programacion y evaluacion de un algoritmo de control basado en logica difusa para el control de velocidad y generacion de potencia electrica de una turbina de gas. En el esquema de control velocidad/carga de la turbina de gas, se sustituyeron completamente los dos controladores convencionales del tipo PI por controladores difusos, teniendo asi un control digital directo. Los controladores difusos corresponden a sistemas MISO que utilizan como variables de entrada el error y la derivada del error, y como variable de salida la senal de control a la valvula de combustible. De esta forma, un controlador difuso provee un algoritmo que puede convertir una estrategia de control linguistico (basado en conocimiento de expertos

  2. Analysis and design of a dish/Stirling system for solar electric generation with a 2.7 kW air-cooled engine; Analisis y diseno de un sistema de generacion electrica termosolar con concentrador de disco parabolico y motor Stirling de 2.7 kW enfriado por aire

    Energy Technology Data Exchange (ETDEWEB)

    Beltran-Chacon, R.; Velazquez-Limon, N. [Universidad Autonoma de Baja California, Baja California (Mexico)]. E-mails: rbeltran1@uabc.edu.mx; nicolas.velazquez@uabc.edu.mx; Sauceda-Carvajal, D. [Universidad Politecnica de Baja California, Baja California (Mexico)]. E-mail: dsaucedac@upbc.edu.mx

    2012-01-15

    This paper presents a mathematical modeling, simulation and design of a solar power system of a parabolic dish with an air-cooled Stirling engine of 2.7 kW. The model used for the solar concentrator, the cavity and the Stirling engine were successfully validated against experimental data. Based on a parametric study, the design of the components of the engine is carried out. The study shows that as system capacity increases, the overall efficiency is limited by the power required by the fan, since the design of the cooler needs greater amounts of heat removal by increasing the air flow without affecting the internal conditions of the process (mass flow of working gas and internal dimensions of the same). The system was optimized and achieves an overall efficiency of solar to electric energy conversion of 26.7%. This study shows that the use of an air-cooled Stirling engine is potentially attractive for power generation at low capacities. [Spanish] Este trabajo presenta un modelado matematico, la simulacion y diseno de un sistema de generacion electrica termosolar de disco parabolico con motor Stirling de 2.7 kW enfriado directamente por aire. El modelo utilizado para el concentrador, la cavidad y el motor Stirling, fueron validados satisfactoriamente con datos experimentales. Con base en un estudio parametrico se realizo el dimensionamiento de los componentes del motor. El estudio realizado muestra que conforme se incrementa la capacidad del sistema, la eficiencia global se ve limitada por la potencia requerida por el ventilador, dado que el diseno del enfriador necesita retirar mayores cantidades de calor aumentando el flujo de aire, sin afectar las condiciones internas del proceso (flujo masico del gas de trabajo y dimensiones internas del mismo). El sistema fue optimizado obteniendo una eficiencia global de conversion de energia solar a electrica de 26.7%. Este estudio muestra que el uso de un motor Stirling enfriado directamente por aire es potencialmente

  3. Methodology for the electric energy distribution systems planning of small and rural zones of Comision Federal de Electricidad; Metodologia para la planeacion de sistemas de distribucion de energia electrica de zonas pequenas y rurales de Comision Federal de Electricidad

    Energy Technology Data Exchange (ETDEWEB)

    Ochoa Gomez, Miguel Armando

    2008-12-15

    institutional procedures, the standards, the commercial programs and the programs developed by the Management of Planning, used in the CFE to make the electric distribution systems planning. In the same way, in Chapter 4 a methodology for the optimization of the electrical grids in low tension is proposed, standing out some errors that are commonly committed in the design of these types of networks, doing recommendations to correct them with low cost investments. Because of the importance in the design of medium tension lines, in Chapter 3 the set of economic conductors for 23 kV was determined for urban and rural areas, system type A (3F-4H, 2F-3H, 1F-2H), by means of the Modified Method. With this information we will be able to select the conductor that offers the best economy in the time, in each extension of the network. In Chapter 5 the proposed methodology in the planning of the electrical system of distribution of the Zapotlan Zone was applied, as much in substations as in the high and medium tension network. In this chapter analyses of optimization of the network were performed, capacitor banks application, attention to the incremental demand, power losses, contingencies by fault and reliability of the provision. Finally the obtained conclusions of the investigation and the work carried out are presented; as well as the recommendations for future facilities. [Spanish] Las 13 Divisiones de Distribucion en las cuales la Comision Federal de Electricidad (CFE) tiene estructurada, administrativa y tecnicamente, la distribucion de la energia electrica en su territorio atendido, estan constituida a su vez por un total de 120 Zonas de Distribucion, clasificadas conforme al producto de su numero de clientes, por su volumen de ventas anuales, en media y baja tension, como zonas tipo I, II y III. Ejemplos de zonas tipo III son las Zona Guadalajara y la Zona Metropolitana Monterrey Norte, Oriente y Poniente (metropolis), la tipo II son zonas predominantemente urbanas como Queretaro

  4. INFRAESTRUCTURA DE COMUNICACIONES EN MICRORREDES ELECTRICAS

    Directory of Open Access Journals (Sweden)

    Elvis Eduardo Gaona García

    2014-11-01

    Full Text Available Este artículo muestra un estudio de la actualidad técnica y tecnológica de la infraestructura de comunicaciones utilizadas en  microrredes eléctricas, en este sentido ha surgido la necesidad de investigar, analizar, mejorar y desarrollar métodos de comunicación tanto alámbricos como inalámbricos que permitan crear una infraestructura de comunicaciones que soporte las características de control, supervisión y trasmisión de información entre dispositivos de control en una microrred de forma eficiente, segura y confiable.Dadas estas características en el artículo se analizan  las diferentes arquitecturas y topologías propuestas entorno a comunicaciones en el ambiente Smart Grid que se puedan adaptar a la forma en que opera una microrred. Se muestran las propuestas  y desarrollos realizados en el  área de telecomunicaciones concerniente a protocolos de comunicaciones utilizados en microrredes eléctricas, con el fin de conocer las tecnologías, protocolos y algoritmos utilizados en la transmisión de datos.

  5. The Chernobyl accident and the Spanish nuclear power plants. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-11-15

    On the morning of April 26, 1986, Unit 4 of the Chernobyl Nuclear Power Plant (Ukraine, USSR) suffered an accident of the greatest magnitude among those which have taken place in nuclear energy installations employed for peaceful uses. The accident reached a degree of severity unknown up to now in nuclear energy generating plants, both with respect to the loss of human lives and the effects caused to the neighboring population (as well as to other nations within a wide radius of radioactivity dispersal), and also with respect to the damage caused in the nuclear plant itself. In the light of the anxiety created internationally, the USSR State Committee for the Utilization of Atomic Energy prepared a report (1), based on the conclusions of the Governmental Commission entrusted to study the causes of the accident, which was presented at the international meeting of experts held at the International Atomic Energy Agency (IAEA) headquarters in Vienna from August 25 to 29, 1986. The present technical report has been prepared by the Spanish nuclear power plants within the framework of UNIDAD ELECTRICA, S.A. (UNESA) - the Association of Spanish electric utilities - in collaboration with EMPRESARIOS AGRUPADOS, S.A. The report reflects the utilities' analyses of the causes and consequences of the accident and, based on similarities and differences with Spanish plants under construction and in operation, intends to: a. Evaluate the possibility of an accident with similar consequences occurring in a Spanish plant b. Identify possible design and operation modifications indicated by the lessons learned from this accident.

  6. The Chernobyl accident and the Spanish nuclear power plants. Technical report

    International Nuclear Information System (INIS)

    1986-11-01

    On the morning of April 26, 1986, Unit 4 of the Chernobyl Nuclear Power Plant (Ukraine, USSR) suffered an accident of the greatest magnitude among those which have taken place in nuclear energy installations employed for peaceful uses. The accident reached a degree of severity unknown up to now in nuclear energy generating plants, both with respect to the loss of human lives and the effects caused to the neighboring population (as well as to other nations within a wide radius of radioactivity dispersal), and also with respect to the damage caused in the nuclear plant itself. In the light of the anxiety created internationally, the USSR State Committee for the Utilization of Atomic Energy prepared a report (1), based on the conclusions of the Governmental Commission entrusted to study the causes of the accident, which was presented at the international meeting of experts held at the International Atomic Energy Agency (IAEA) headquarters in Vienna from August 25 to 29, 1986. The present technical report has been prepared by the Spanish nuclear power plants within the framework of UNIDAD ELECTRICA, S.A. (UNESA) - the Association of Spanish electric utilities - in collaboration with EMPRESARIOS AGRUPADOS, S.A. The report reflects the utilities' analyses of the causes and consequences of the accident and, based on similarities and differences with Spanish plants under construction and in operation, intends to: a. Evaluate the possibility of an accident with similar consequences occurring in a Spanish plant b. Identify possible design and operation modifications indicated by the lessons learned from this accident

  7. Questions to the reactors power upgrade of the Nuclear Power Plant of Laguna Verde; Cuestionamientos al aumento de potencia de los reactores de la Central Nuclear de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Salas M, B., E-mail: salasmarb@yahoo.com.mx [UNAM, Facultad de Ciencias, Departamento de Fisica, Circuito exterior s/n, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2014-08-15

    The two reactors of the Nuclear Power Plant of Laguna Verde (NPP-L V) were subjected to power upgrade labors with the purpose of achieving 20% upgrade on the original power; these labors concluded in August 24, 2010 for the Reactor 1 and in January 16, 2011 for the Reactor 2, however in January of 2014, the NNP-L V has not received by part of the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) the new Operation License to be able to work with the new power, because it does not fulfill all the necessary requirements of safety. In this work is presented and analyzed the information obtained in this respect, with data provided by the Instituto Federal de Acceso a la Informacion Publica y Proteccion de Datos (IFAI) and the Comision Federal de Electricidad (CFE) in Mexico, as well as the opinion of some workers of the NPP-L V. The Governing Board of the CFE announcement that will give special continuation to the behavior on the operation and reliability of the NPP-L V, because the frequency of not announced interruptions was increased 7 times more in the last three years. (Author)

  8. EP 1000 -The European Passive Plant

    International Nuclear Information System (INIS)

    Cummins, Ed; Oyarzabal, Mariano; Saiu, Gianfranco

    1998-01-01

    A group of European utilities, along with Westinghouse and its industrial partner GENESI (an Italian consortium including ANSALDO and FIAT) initiated a program to evaluate Westinghouse passive nuclear plant technology for application in Europe. The European utility group consisted of: Agrupacion electrica para al Desarrollo Technologico Nuclear (DTN), Spain; Electricite de France; ENEL, SpA., Italy; IVO Power Engineering, Ltd., Finland; Scottish Nuclear Limited (acting for itself on behalf of Nuclear Electric plc, U.K.; Tractebel Energy Engineering, Belgium; UAK (represented by NOK-Beznau), Switzerland; and Vattenfall AB, Ringhals, Sweden. The European Passive Plant (EPP) program, which began in 1994, is an evaluation of the Westinghouse 600 MWe AP 600 and 1000 MWe Simplified Pressurized Water Reactor (SPWR) designs in meeting the European Utility Requirements (EUR), and where necessary, modifying the design to achieve compliance. Phase 1 or the EPP program was completed and included the two major tasks of evaluating the effect of the EUR on the Westinghouse nuclear island and developing the EP 1000, a 1000 MWe passive plant reference design that conforms to the EUR and would be licensable in Europe. The EP 1000 closely follows the Westinghouse SPWR design for safety systems and containment and the AP 600 design for auxiliary systems. It also includes features that where required to meet the EUR and key European licensing requirements. The primary circuit of the EP 1000 retains most of the general features of the current-day designs, but some evolutionary features to enhance reliability, simplicity of operation, ease of maintenance, and plant safety have been incorporated into the design. The core, reactor vessel, and reactor internals of the EP 1000 are similar to those of currently operating Westinghouse PWR plants, but several new features are included to enhance the performance characteristics. The basic EP 1000 safety philosophy is based on use of inherent

  9. Evaluation of the problematic of corrosion in bottoms of tanks of crude oil storage; Evaluacion de la problematica de corrosion en fondos de tanques de almacenamiento de petroleo crudo

    Energy Technology Data Exchange (ETDEWEB)

    Malo T, Jose M; Uruchurtu C, Jorge; Meza, Beatriz [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Lopez C, Luis F [Region Marina Suroeste, Pemex (Mexico)

    2003-07-01

    In this article the results related to the corrosive aggressiveness of the water fluids of crude oil of the Marine Terminal of Dos Bocas (TMDB), on the effectiveness of the anticorrosive control methods and on the control measures that could be adopted are presented. Also, this article comprises a work made by personnel of the Instituto de Investigaciones Electricas (IIE) during year 2002. The corrosion in tanks is of electrochemical nature and has its origin in the watery phase that accompanies the crude oil on being extracted from underground. In the case of the storage tanks, the watery phase separates at the bottom, causing the wetness of the bottom steel plates and its degradation. Due to the limited access to the interior of the tank during its operation, a testing device was designed that was connected to a drain valve of a tank of the terminal. The experimental work looked for the evaluation of the aggressiveness of the fluids, the type of corrosion products formed and the effectiveness of the cathodic protection and of the coatings. Additionally, fluid samples were collected, for analyzing the natural aggressiveness level that presents the water contained in the three types of crude: Mayan, Olmeca and Istmo handled in the terminal, studying steel samples and of plant fluids under controlled laboratory conditions. The aggressiveness was obtained from measurements of corrosion rates and analysis of microbial activity. The feasibility of applying the method of cathodic protection was analyzed, observing its effectiveness, as well as particular corrosion forms as the ones that occur in the pontoons. The results of the study lead to propose a monitoring scheme to pursuit the integrity of the coatings, the operation of the cathodic protection and the corrosion in tanks, with which a better control of the operation of the anticorrosive methods and of the degradation that occurs with the corrosion, could be obtained. [Spanish] En este trabajo se presentan

  10. Solution to the incompatibility between reactor protection logic and turbine shot logic. Scram by high pressure; Solucion a la incompatibilidad entre logica de proteccion de reactor y logica de disparo de turbina. SCRAM por alta presion

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Q, R.; Santiago F, C.; Gonzalez P, G., E-mail: ruben.ramos01@cfe.gob.mx [Comision Federal de Electricidad, Central Nuclear Laguna Verde, Subgerencia de Ingenieria, Carretera Cardel-Nautla Km. 42.5, Alto Lucero, Veracruz (Mexico)

    2013-10-15

    The nuclear power plant of Laguna Verde carried out the Modernization and Increase of Extended Power Project in its two Units (2005-2011). This modernization included to the electro-hydraulic control system of the main turbine, replacing an ana logical system by one digital (Digital Electro-hydraulic Control - DEHC) whose functions are of controlling the reactor pressure in the different operation ways as wells as of controlling the velocity and load of the main turbine. Also, it has protections that are related with diverse plant systems, as the Reactor Protection Systems (RPS). During the tests stage was realized a programmed load rejection, which Reactor Scram should cause when being presented the shot of main turbine. However, the logic of the RPS was inhibited due to the quick response of the new control DEHC, propitiating a condition of non prospective plant and, in consequence, the Reactor Scram happened for another protection of the RPS. (author)

  11. Medicinal Plants.

    Science.gov (United States)

    Phillipson, J. David

    1997-01-01

    Highlights the demand for medicinal plants as pharmaceuticals and the demand for health care treatments worldwide and the issues that arise from this. Discusses new drugs from plants, anticancer drugs, antiviral drugs, antimalarial drugs, herbal remedies, quality, safety, efficacy, and conservation of plants. Contains 30 references. (JRH)

  12. Plant walkdown

    International Nuclear Information System (INIS)

    Kostov, M.

    2000-01-01

    This report covers the following: preparatory steps for performing plant walk-down; the objective of the first plant walk-down; plant walk-down procedures; earthquake screening evaluation; walk-down documentation; second plant walk-down. The following objectives concerning the plant walk-down(s) were achieved. The plant system configuration is verified in order to proceed with event tree and fault tree analyses. Systems interactions, other types of dependencies or plant unique features are identified. he safety related components that are judged to generically possess high capacities (i.e., larger than the earthquake review level) have been verified to contain no weaknesses. Further analyses needed to establish the capacities of remaining safety-related components are identified and necessary field data are obtained. Information on components is obtained to assist in HCLPF (fragility) evaluation and peer review of the seismic margin study

  13. Aquatic plants

    DEFF Research Database (Denmark)

    Madsen, T. V.; Sand-Jensen, K.

    2006-01-01

    Aquatic fl owering plants form a relatively young plant group on an evolutionary timescale. The group has developed over the past 80 million years from terrestrial fl owering plants that re-colonised the aquatic environment after 60-100 million years on land. The exchange of species between terre...... terrestrial and aquatic environments continues today and is very intensive along stream banks. In this chapter we describe the physical and chemical barriers to the exchange of plants between land and water.......Aquatic fl owering plants form a relatively young plant group on an evolutionary timescale. The group has developed over the past 80 million years from terrestrial fl owering plants that re-colonised the aquatic environment after 60-100 million years on land. The exchange of species between...

  14. Analysis of Methodologies for Identifying Exclusion Zones for Concentrating Solar Power (CSP); Analisis de Metodologias de Identificacion de Zonas de Exclusion para Estudios de Potencial de Energia Electrica Termosolar (CSP)

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez, P.; Ramirez, L.; Navarro, A. A.; Polo, J.; Zarza, E.

    2013-07-01

    The aim of this study is the proposal of a valid and unique methodology to any territory of the potential for solar power generation, reducing subjectivity and enabling comparison of results from the examination of several existing methodologies for CSP, particularly those developed by the Institute for diversification and saving of Energy (IDAE), Greenpeace, National renewable energy laboratory (NREL) and the German Aerospace Center (DLR). Subsequently, we apply and compare the results obtained with those already installed CSP plants, giving an idea of the suitability of each methodology to locate plants in areas considered suitable. (Author)

  15. Incorporating environmental constraints to electricity generation in the city of Buenos Aires; Despacho economico-ambiental de la oferta de generacion de energia electrica en la ciudad de Buenos Aires

    Energy Technology Data Exchange (ETDEWEB)

    Dawidowski, Laura E; Gomez, Dario R; Bajano, Hector [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Quimica; Anbinder, Gustavo D; Rey, Francisco C [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Reactores y Centrales Nucleares

    1999-07-01

    A prototype for an integrated system that includes air quality constraints to the procedure that is presently in use to determine the daily economic dispatch of power plants in Argentina is proposed. The recent incorporation of new machines to the installed capacity of the three power plants located in the densely populated metropolitan area of Buenos Aires, the thermal-based future expansion of the power sector and the relatively high nitrogen oxides concentrations that can be associated to electricity generation in the city of Buenos Aires, served to motivate this work. The prototype attempts to generate a dispatch that is compatible with the environment taking into account the present economic dispatch, weather forecast and dispersion models to evaluate ambient air concentrations of nitrogen oxides (NO{sub x}) caused by the combined operation of the thermal power plants. Although the prototype deals exclusively with NO{sub x}, since these are the pollutants of primary concern considering the fuel consumption pattern of argentinean power plants, its structure is general enough to take into account other pollutants such as sulfur dioxide and particulate matter. (author)

  16. Electronic plants

    Science.gov (United States)

    Stavrinidou, Eleni; Gabrielsson, Roger; Gomez, Eliot; Crispin, Xavier; Nilsson, Ove; Simon, Daniel T.; Berggren, Magnus

    2015-01-01

    The roots, stems, leaves, and vascular circuitry of higher plants are responsible for conveying the chemical signals that regulate growth and functions. From a certain perspective, these features are analogous to the contacts, interconnections, devices, and wires of discrete and integrated electronic circuits. Although many attempts have been made to augment plant function with electroactive materials, plants’ “circuitry” has never been directly merged with electronics. We report analog and digital organic electronic circuits and devices manufactured in living plants. The four key components of a circuit have been achieved using the xylem, leaves, veins, and signals of the plant as the template and integral part of the circuit elements and functions. With integrated and distributed electronics in plants, one can envisage a range of applications including precision recording and regulation of physiology, energy harvesting from photosynthesis, and alternatives to genetic modification for plant optimization. PMID:26702448

  17. Electrical modifications carried out in C.N. Trillo as a result of the findings of the tests of effort; Modificaciones electricas realizadas en CN Trillo como resultado de las conclusiones de las pruebas de esfuerzo realizadas

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Fernandez-Jardon, P.; Vicente Mendez, J. de

    2014-07-01

    They fall within the set of implemented measures to increase the robustness of the plant against further than the foundations of design, that accidents are taken in response to the ITC of the Consejo de Seguridad Nuclear as a result the findings of the stress tests. The main objective of these electric changes is to provide consumers important to deal with accidents more than the Bases of design of greater availability in the scenarios considered feeds.

  18. Improving of health and safety contribution of OECD/NEA Radiation Protection Committee and Public Health; Mejora de la salud publica y la seguridad. contribuciones de la OECD/NEA, comite de Proteccion Radiologia y Salud Publica

    Energy Technology Data Exchange (ETDEWEB)

    Lazo, T.

    2004-07-01

    The OECD Nuclear energy Agency, has, since 1957, been addressing issues in radiological protection through its Committee on Radiation Protection and Public Health (CRPPH). The Committee is made up of regulators and radiation protection experts, with the broad mission to provide timely identification of new and emerging issues, to analyse their possible implications and to recommend or take action to address these issues to further enhance radiation protection regulation and implementation. The regulatory and operational consensus developed by the CRPPH on these emerging issues supports policy and regulation development in Member countries, and disseminates good practice. To best serve the needs of its Member countries, the CRPPH has been focusing its work in recent years on a few key topic areas. These induce the evolution of the system of radiological protection, the advancement of preparedness for nuclear emergency accidents, and the improvement of occupational exposure management at nuclear power plants. With the International Commission on Radiological Protection about to issue new recommendations, due out in 2005, the CRPPH will take advantage of the radiological protection community's recent focus on emerging policy and strategic issues to develop a new CRPPH Collective Opinion. This document, to be published in 2005, will serve the Committee as a guide for its programme of work for the coming 5 to 10 years. (Author) 13 refs.

  19. A practical methodology of radiological protection for the reduction of hot particles in BWR type reactors; Una metodologia practica de proteccion radiologica para la reduccion de particulas calientes en reactores BWR

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez G, G [Comision Federal de Electricidad, Gerencia del Proyecto Nucleoelectrico Laguna Verde, Disciplina de Fisica Aplicada (Mexico)

    1991-07-01

    The purpose of this work, in general form, is to describe a practical method for reduction of hot particles generated as consequence of the operational activities of BWR nuclear reactors. This methodology provides a description of the localizations and/or probable activities of finding particles highly radioactive denominated hot particles. For this purpose it was developed a strategy based on the decontamination lineaments, as well as the manipulation, gathering, registration, contention, documentation, control and final disposition of the hot particles. In addition, some recommendations are reiterated and alternative, in order to gathering the hot particles in a dynamic way given to the activities of the personal occupationally exposed in highly radioactive areas. The structure of the methodology of hot particles is supported in the radiological controls based on the Code of Federal Regulation 10 CFR 20 as well as the applicable regulatory documents. It provides an idea based on administrative controls of radiological protection, in order to suggesting the responsibilities and necessary directing for the control of the hot particles required in nuclear plants of the BWR type. (author)

  20. Plant embryogenesis

    NARCIS (Netherlands)

    Vries, de Sacco C.; Weijers, Dolf

    2017-01-01

    Land plants are called ‘embryophytes’ and thus, their collective name is defined by their ability to form embryos. Indeed, embryogenesis is a widespread phenomenon in plants, and much of our diet is composed of embryos (just think of grains, beans or nuts; Figure 1). However, in addition to embryos

  1. Boehringer Ingelheim Promeco contemplates the benefits of cogeneration in its new plant; Boehringer Ingelheim Promeco contempla beneficios de la cogeneracion para su nueva planta

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Esparza, R. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico); Khouri Solis, A. [Boehringer Ingelheim Promeco, Mexico, D. F. (Mexico)

    1997-12-31

    This paper presents the results of the feasibility study performed in BOEHRINGER INGELHEIM PROMECO to determine the benefits that a cogeneration system could render in satisfying the energy demand of its plant currently being expanded. The results showed that in accordance with the operation mode of the already expanded plant, the highest benefits could be obtained of a cogeneration system with a capacity of 1,600 Kw that would partially satisfy the thermal and electrical demands of BOEHRINGER INGELHEIM PROMECO. [Espanol] El presente articulo presenta los resultados de factibilidad que se realizo en Boehringer Ingelheim Promeco para determinar los beneficios que podria rendir un sistema de cogeneracion al satisfacer las demandas energeticas de su planta actualmente en ampliacion. Los resultados mostraron que de acuerdo al modo de operacion de la planta ya ampliada, los beneficios mas altos se obtendrian de un sistema de cogeneracion con capacidad de 1,600 kW que satisfaria parcialmente las demandas termicas y electricas de Boehringer Ingelheim Promeco.

  2. Boehringer Ingelheim Promeco contemplates the benefits of cogeneration in its new plant; Boehringer Ingelheim Promeco contempla beneficios de la cogeneracion para su nueva planta

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Esparza, R [Instituto de Investigaciones Electricas, Cuernavaca (Mexico); Khouri Solis, A [Boehringer Ingelheim Promeco, Mexico, D. F. (Mexico)

    1998-12-31

    This paper presents the results of the feasibility study performed in BOEHRINGER INGELHEIM PROMECO to determine the benefits that a cogeneration system could render in satisfying the energy demand of its plant currently being expanded. The results showed that in accordance with the operation mode of the already expanded plant, the highest benefits could be obtained of a cogeneration system with a capacity of 1,600 Kw that would partially satisfy the thermal and electrical demands of BOEHRINGER INGELHEIM PROMECO. [Espanol] El presente articulo presenta los resultados de factibilidad que se realizo en Boehringer Ingelheim Promeco para determinar los beneficios que podria rendir un sistema de cogeneracion al satisfacer las demandas energeticas de su planta actualmente en ampliacion. Los resultados mostraron que de acuerdo al modo de operacion de la planta ya ampliada, los beneficios mas altos se obtendrian de un sistema de cogeneracion con capacidad de 1,600 kW que satisfaria parcialmente las demandas termicas y electricas de Boehringer Ingelheim Promeco.

  3. Specification for the interconnection to a electric network of low tension of photovoltaic systems with 30 kW of capacity; Especificacion para la interconexion a la red electrica de baja tension de sistemas fotovoltaicos con capacidad hasta 30kW

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Gutierrez, Jose [Comision Federal de Electricidad, Mexico (Mexico)

    2007-06-15

    In this presentation, there are shown the details of the photovoltaic systems interconnected with the electric network (SFVI), carried out by the Mexico's Federal Electricity Commission (CFE) with the support of the Mexican Electric Research Institute (IIE). First of all, there are found the objectives of the photovoltaic system interconnected to the electric network (SFVI). Then, there are mentioned the places where such sort of systems could be installed; besides, it is shown a diagram explaining the process of such systems. At the same time, there are briefly explained the components that are necessaries for their properly operation. Some of the elements previously mentioned are: photovoltaic generator (GFV), inverter, interface, and logic circuits and the control. It is shown a diagram with the location of the electrical disconnect switches. Then, it is shortly explained the place where the SFVI should be connected and there are given some requisites that are important to fulfill in order to have everything updated. Finally, it is mentioned the methodology that should be followed in order to supervise that everything works in a properly way, this last issue is carried out by CFE. [Spanish] En esta presentacion se presentan los pormenores del sistema fotovoltaico interconectado a la red (SFVI), realizado por la Comision federal de Electricidad (CFE) con apoyo del Instituto de Investigaciones Electricas (IIE). En primer lugar, se encuentran los objetivos que tiene el uso de SFVI. Enseguida, se muestra un diagrama que explica el proceso que dichos sistemas realizan. Asimismo, se explican brevemente los elementos que, de uno u otro modo, son necesarios para el adecuado funcionamiento del SFV. Ademas, se muestra un diagrama con la ubicacion de los interruptores de desconexion. Luego, se explica escuetamente el lugar donde se debe de conectar el SFVI, ademas de algunas condiciones que se deben de cumplir para que no haya mayores contratiempos. Finalmente, se

  4. Program integration at JVC Industrial de Mexico, S.A. de C.V./Electric energy saving/Environmental management system /ISO 14001 standard; Integracion de programas en JVC Industrial de Mexico, S.A. de C.V. Ahorro de energia electrica/Sistema de administracion ambiental/Estandar ISO 14001

    Energy Technology Data Exchange (ETDEWEB)

    Argote Molina, Martin [JVC Industrial de Mexico S. A. de C. V., Tijuana (Mexico)

    1998-12-31

    It is possible, and besides logic, the integration of programs such as the electric energy saving and an environmental management system. In managing the consumption and the demand of the electric service, there is an effect on the pollutants emitted for the generation. It is clear that the user in not, and can not be, responsible for the type of fuel used but its importance in project planning is out of question. In its turn the central point of the environmental management system, consists in identifying the main effects on the environment caused by its activities, services and products, as well as the current or potential control level of the enterprise on them. Such identification and further evaluation took us at JVC Industrial de Mexico, to integrate conceptually and operationally such programs. The commitment with the Management was concentrated and strengthened resulting in a fuller consciousness of resource administration. [Espanol] Es posible, ademas de logica, la integracion de programas tales como el ahorro de energia electrica y un sistema de administracion ambiental. Al administrar el consumo y la demanda del servicio electrico tenemos un efecto en los contaminantes emitidos para la generacion. Es claro que el usuario no es, ni puede ser, responsable del tipo de combustible utilizado pero su importancia en la planeacion de proyectos es indiscutible. A su vez el punto central del sistema de administracion ambiental, consiste en identificar los principales efectos en el medio ambiente causados por sus actividades, servicios o productos, asi como el nivel de control actual o potencial de la empresa sobre ellos. Dicha identificacion y la posterior evaluacion nos llevo, en JVC Industrial de Mexico, a integrar tanto conceptual como operacionalmente dichos programas. El compromiso de la Gerencia se vio concentrado y fortalecido dando como resultado una conciencia mas plena de la administracion de recursos.

  5. Program integration at JVC Industrial de Mexico, S.A. de C.V./Electric energy saving/Environmental management system /ISO 14001 standard; Integracion de programas en JVC Industrial de Mexico, S.A. de C.V. Ahorro de energia electrica/Sistema de administracion ambiental/Estandar ISO 14001

    Energy Technology Data Exchange (ETDEWEB)

    Argote Molina, Martin [JVC Industrial de Mexico S. A. de C. V., Tijuana (Mexico)

    1999-12-31

    It is possible, and besides logic, the integration of programs such as the electric energy saving and an environmental management system. In managing the consumption and the demand of the electric service, there is an effect on the pollutants emitted for the generation. It is clear that the user in not, and can not be, responsible for the type of fuel used but its importance in project planning is out of question. In its turn the central point of the environmental management system, consists in identifying the main effects on the environment caused by its activities, services and products, as well as the current or potential control level of the enterprise on them. Such identification and further evaluation took us at JVC Industrial de Mexico, to integrate conceptually and operationally such programs. The commitment with the Management was concentrated and strengthened resulting in a fuller consciousness of resource administration. [Espanol] Es posible, ademas de logica, la integracion de programas tales como el ahorro de energia electrica y un sistema de administracion ambiental. Al administrar el consumo y la demanda del servicio electrico tenemos un efecto en los contaminantes emitidos para la generacion. Es claro que el usuario no es, ni puede ser, responsable del tipo de combustible utilizado pero su importancia en la planeacion de proyectos es indiscutible. A su vez el punto central del sistema de administracion ambiental, consiste en identificar los principales efectos en el medio ambiente causados por sus actividades, servicios o productos, asi como el nivel de control actual o potencial de la empresa sobre ellos. Dicha identificacion y la posterior evaluacion nos llevo, en JVC Industrial de Mexico, a integrar tanto conceptual como operacionalmente dichos programas. El compromiso de la Gerencia se vio concentrado y fortalecido dando como resultado una conciencia mas plena de la administracion de recursos.

  6. Replacement of electrical protection of generation (main generator, main transformer and auxiliary transformers) and new associated monitoring system; Sustitucion de portecciones electricas de generacion (genrador principal, transformador principal y transformadores auxiliares) y nuevo sistema de supervision asociado

    Energy Technology Data Exchange (ETDEWEB)

    Archilla, J.

    2013-07-01

    The replacement of the electrical protection of generation is a technological quantum leap, since moving from an analog system (known by) (all, intuitive and visual) to a digital (integrates the hardware on a single computer, much more powerful and programmable). The keys to overcoming the challenge are know to manage the technological leap, the operational limitations of plant (keep operating the)preferred sources of energy) and make a good design (including a review independent of the configuration of the relays, taking into account the experience (operational available).

  7. Upgrading of operation and maintenance. Lessons learned by ENEL- Nuclear Plant Management

    International Nuclear Information System (INIS)

    Bolla, Giuseppe; Panini, Giulio

    1999-01-01

    A presentation and general information on ENEL are given. The Italian Authority for Electric Energy (Ente Nazionale per l'Energia Electrica - ENEL), entirely owned by the Italian Ministry of Treasury, is the third largest utility in the world after EDF of France and TEPCO of Japan. The following figures are featuring its size: - Net maximum capacity = 52.463 GW; - Power generation = 182,500 GW h; - Customer = 28.2 Million; - Hydroelectric power plants = 651 (16.327 MW); - Thermoelectric power units = 206 (35,666 MW); - Geothermal power units = 36 (470 MW). The ENEL core business consists of generation, transmission, distribution and sale throughout Italy of electric power produced from any source as well as the importation and exportation of electric power and the co-ordination of operational and planning activities in order to ensure adequate availability throughout Italian territory of electric power at minimum cost. Before the decision taken for political reason by Italian Government in 1988 to terminate nuclear power plants operation and construction, 4 NPPs have been successfully operated. The whole production of the four plants has been about 90 billion kWh. The management experience for these plants has been good, both for plant availability and safety. No operating events occurred arising any risk for workers, population and environment. The Chernobyl power plant accident induced Italy to promote the 'nuclear referendum' in November 1987. Following the referendum the nuclear power production was interrupted. After 1988 the following nuclear activities has been carried out: - plant safe conservation, decommissioning planning, cost evaluation and safe enclosure preparation; - investigation for waste treatment methods; - participation in requirement definition and design activity for next NPP generation. A specific experience has been accumulated in the decommissioning of Italian NPPs, due to their anticipated shutdown, in particular in the field of

  8. Plant Macrofossils

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Records of past vegetation and environmental change derived from plant remains large enough to be seen without a microscope (macrofossils), such as leaves, needles,...

  9. T Plant

    Data.gov (United States)

    Federal Laboratory Consortium — Arguably the second most historic building at Hanford is the T Plant.This facility is historic in that it's the oldest remaining nuclear facility in the country that...

  10. Lunar Plants

    Data.gov (United States)

    National Aeronautics and Space Administration — We present an open design for a first plant growth module on the Moon (LPX). The primary science goal of lunar habitat is to investigate germination and initial...

  11. Alien plants

    Science.gov (United States)

    2018-04-01

    No-one’s ever travelled to an extrasolar planet, or even observed one that we’re sure harbours life. But if plants do exist on such alien worlds, we can have fun speculating what form they might take.

  12. Plant simulator

    International Nuclear Information System (INIS)

    Fukumitsu, Hiroyuki

    1998-01-01

    A simulator of a reactor plant of the present invention comprises a plurality of distributed computers, an indication processing section and an operation section. The simulation calculation functions of various kinds of plant models in the plant are shared by the plurality of computers. The indication processing section controls collection of data of the plant simulated by the computers and instructions of an operator. The operation section is operated by the operator and the results of operation are transmitted to the indication processing section, to conduct operation trainings and display the results of the simulation. Each of the computers and the indication processing portion are connected with each other by a network having a memory for common use. Data such as the results of calculation of plant models and various kinds of parameters of the plant required commonly to the calculators and the indication processing section are stored in the common memory, and adapted to be used by way of the network. (N.H.)

  13. Plant automation

    International Nuclear Information System (INIS)

    Christensen, L.J.; Sackett, J.I.; Dayal, Y.; Wagner, W.K.

    1989-01-01

    This paper describes work at EBR-II in the development and demonstration of new control equipment and methods and associated schemes for plant prognosis, diagnosis, and automation. The development work has attracted the interest of other national laboratories, universities, and commercial companies. New initiatives include use of new control strategies, expert systems, advanced diagnostics, and operator displays. The unique opportunity offered by EBR-II is as a test bed where a total integrated approach to automatic reactor control can be directly tested under real power plant conditions

  14. Plant intelligence

    Science.gov (United States)

    Lipavská, Helena; Žárský, Viktor

    2009-01-01

    The concept of plant intelligence, as proposed by Anthony Trewavas, has raised considerable discussion. However, plant intelligence remains loosely defined; often it is either perceived as practically synonymous to Darwinian fitness, or reduced to a mere decorative metaphor. A more strict view can be taken, emphasizing necessary prerequisites such as memory and learning, which requires clarifying the definition of memory itself. To qualify as memories, traces of past events have to be not only stored, but also actively accessed. We propose a criterion for eliminating false candidates of possible plant intelligence phenomena in this stricter sense: an “intelligent” behavior must involve a component that can be approximated by a plausible algorithmic model involving recourse to stored information about past states of the individual or its environment. Re-evaluation of previously presented examples of plant intelligence shows that only some of them pass our test. “You were hurt?” Kumiko said, looking at the scar. Sally looked down. “Yeah.” “Why didn't you have it removed?” “Sometimes it's good to remember.” “Being hurt?” “Being stupid.”—(W. Gibson: Mona Lisa Overdrive) PMID:19816094

  15. PLANT DIVERSITY

    Science.gov (United States)

    Habitat change statistics and species-area curves were used to estimate the effects of alternative future scenarios for agriculture on plant diversity in Iowa farmlands. Study areas were two watersheds in central Iowa of about 50 and 90 square kilometers, respectively. Future s...

  16. La teledeteccion satelital y los sistemas de proteccion ambiental

    Directory of Open Access Journals (Sweden)

    Francisco Sacristan Romero

    2005-07-01

    Full Text Available La Teledetección ofrece grandes posibilidades para la realización de progresos en el conocimiento de la naturaleza, aunque todavía no se ha logrado todo lo que de ella se esperaba debido a que se deben realizar perfeccionamientos en el nivel de resolución espacial, espectral y temporal de los datos. Además, es necesario un mayor rigor científico en la interpretación de los resultados obtenidos, tratando de no extraer conclusiones definitivas de los estudios medioambientales realizados mediante técnicas de Teledetección. Los modelos que se elaboran para interpretar los datos de Teledetección, deberán tener como objetivo eliminar los efectos ocasionados por la variabilidad en las condiciones de captación, la distorsión provocada por la atmósfera, y la influencia de parámetros tales como la posición del Sol, pendiente, exposición, y altitud. En este artículo intentaré desgranar las diversas y múltiples aplicaciones de la técnica de la teledetección al control de los residuos con efectos energéticos y medioambientales. The Teledetection offers great possibilities for the accomplishment of progresses in the knowledge of the nature, although everything has still not been obtained what of her it was expected because they think to make improvements in the level of space resolution, spectral and temporary of the data. In addition, a greater scientific rigor in the interpretation of the obtained results is necessary, treating about not drawing definitive conclusions of the made environmental studies by means of techniques of Teledetection. The models that are elaborated to process the data of Teledetection will have to have like objective to eliminate the effects caused by the variability in the conditions of pick up, the distortion caused by the atmosphere and the influence of parameters such as the position of the Sun, slope, exhibition, and altitude.

  17. Proteccion Social en Salud en America Latina y el Caribe ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Dentro de la salud pública, y con vistas a contribuir en los procesos de cambio de ... la PSS en el marco de las reformas de la salud en América Latina y el Caribe. ..... neoliberal” en tanto extiende la racionalidad mercantil a todas las esferas de la ... Excluyentes como El Salvador, Honduras, Bolivia, Ecuador y Guatemala.

  18. Training in radiological protection; Capacitacion en proteccion radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Medina G, E., E-mail: medina@ipen.gob.pe [Instituto Peruano de Energia Nuclear, Av. Canada 1470, San Borja, Lima 41 (Peru)

    2014-08-15

    In the Peru, according to the current regulations, people that work with ionizing radiations should have an authorization (individual license), which is granted by the Technical Office of the National Authority that is the technical body of the Instituto Peruano de Energia Nuclear (IPEN) manager of the control of ionizing radiations in the country. The individual license is obtained after the applicant fulfills the requested requirements, as having safety knowledge and radiological protection. Since its founding in 1972, the Centro Superior de Estudios Nucleares (CSEN) of the IPEN has carried out diverse training courses in order to that people can work in a safe way with ionizing radiations in medicine, industry and research, until the year 2013 have been organized 2231 courses that have allowed the training of 26213 people. The courses are organized according to the specific work that is carried out with radiations (medical radio-diagnostic, dental radiology, nuclear medicine, radiotherapy, industrial radiography, nuclear meters, logging while drilling, etc.). In their majority the courses are directed to people that will make use of radiations for first time, but refresher courses are also granted in the topic. The CSEN also carries out the Master degree programs highlighting the Second Professional Specialization in Radiological Protection carried out from the year 2004 with the support of the National University of Engineering. To the present has been carried out 2 programs and there is other being developed. In this work is shown the historical evolution of the radiological protection courses as well as the important thing that they are to work in a safe way in the country. (Author)

  19. Transient and steady state analysis in the frequency domain for time-invariant and time variant electrical networks using the algebraic operational matrices approach; Analisis transitorio y de estado estable en el dominio de la frecuencia de redes electricas invariantes y variantes en el tiempo utilizando el enfoque algebraico de las matrices operacionales

    Energy Technology Data Exchange (ETDEWEB)

    Lazaro Castillo, Isidro Ignacio

    1999-02-01

    insight in to the properties of time varying networks by using methods of analysis in the frequency domain, which are well established for the analysis of time-invariant networks. The question arises whether these methods can be applied and modified for the analysis of time varying networks. Some possible solutions have been reported in the open literature. In this thesis a efficient solution is reported, which is based on operational matrices and, according to the author's knowledge, it has not been published before. An advantage of the method is that it can be seen as a direct extension of the Ohm's laws and the nodal analysis widely used in power systems for circuit analysis. The results presented in the thesis are validated with time domain simulations. In all cases the results obtained from both solutions matched with a vary low tolerance. [Spanish] En este trabajo el problema de predecir la distorsion armonica es tratado en forma general. El problema es presentado tal que el proceso de solucion no se limita a mantenerlo en el dominio de Fourier porque puede ser manejado en cualquier otro dominio generado por cualquier base dada por toda expansion en series ortogonales, incluidas las series de Fourier. En este trabajo se muestra que las series ortogonales tales como las series Hartley o Walsh pueden ser utilizadas para resolver mas eficientemente los problemas de distorsion armonica que la forma convencional considera en el dominio armonico. De este trabajo es claro que el dominio armonico es un caso particular de la formulacion aqui presentada. La teoria utilizada para presentar y resolver el problema de la distorsion armonica esta basada principalmente en el concepto de las matrices operacionales desarrolladas en las areas de Control y Sistemas. La aproximacion tiene la ventaja de proporcionar un marco de referencia general para resolver problemas de estado estable y dinamico en redes electricas y sistemas en general. Un hecho importante presentado en

  20. Fussy control for the operation of an electric energy generation system based in type PEM fuel cells; Control difuso para la operacion de un sistema de generacion de energia electrica basado en celdas de combustible tipo PEM

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez Roman, Miguel

    2004-10-15

    In this work, the design of a control system with fuzzy PID controllers is reported. It combines the techniques of multimode control and gain scheduling as well as the design of a compensator that will reduce the interaction effects among control loops in a multivariable system. The simulated system is based on a non-lineal mathematical model. Its validity range supports up to 1440 watts, for a nominal design of 1 KW power. To carry out the fuzzy PID Controller's design, firstly the PID conventional controllers were designed for three operating points of power demand: 0 W, 500 W and 1000 W. The methodology adopted for the determination of the conventional PID controller's parameters was poles cancellation. This methodology demanded the lineal identification of the process for the three mentioned operating points: low, medium and high power. With the information obtained from the adjusted conventional controllers in the three operating points, the design of fuzzy PID controllers based on the TSK system was achieved. For this work, this method is equivalent to the technique of gain scheduling since only conventional PID controllers with the same structure are used. In addition, a control scheme using a compensator that had the function of reducing the interaction effects among the control loops was designed. The compensator was located between the controller and the plant and only introduces compensation factors among control signals, maintaining the direct path of the control loop in the original control scheme. Several tests of the whole operating range, in order to make a performance analysis of both the conventional PID controller and the fuzzy PID controller were carried out, introducing step form signals in the power demand. The performance of the generation system was validated as a function of an error based index minimization as well as on the actuator control signal shape. The dynamic coupling degree among the control loops was analyzed, as well

  1. Stress tolerant plants

    OpenAIRE

    Rubio, Vicente; Iniesto Sánchez, Elisa; Irigoyen Miguel, María Luisa

    2014-01-01

    [EN] The invention relates to transgenic plants and methods for modulating abscisic acid (ABA) perception and signal transduction in plants. The plants find use in increasing yield in plants, particularly under abiotic stress.

  2. Tidal power plant energy estimation; Cuantificacion de energia de una planta mareomotriz

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Gonzalez, J.; Hiriart Le Bert, G.; Silva Casarin, R. [Instituto de Ingenieria, Universidad Nacional Autonoma de Mexico (mexico)]. E-mail: JlopezGo@iingen.unam.mx; gerardo367@yahoo.com.mx; RSilvaC@iingen.unam.mx

    2010-04-15

    In this paper a methodology is presented which allows a quick and simple means of estimating the potential energy that can be obtained from a tidal power plant. The evaluation is made using a normalised nomograph, which is a function of the area of the tidal basin against the electricity installed capacity to thus obtain the potential energy for any location. The results describe two means of operation, one of flow tide and the other flow-ebb tides, with two tidal basin systems operating: single and double reservoir systems. To obtain the normalised nomograph the numerical results for simulations of several tidal power plants under differing operational conditions over a period of one year. These conditions were established by varying the electricity installed capacity, the hydraulic conditions in flow tide, ebb tides or both and with single or double reservoir systems and using sea level information taken every 15 minutes. To validate the model information from the tidal power plant at Rance, France, was used, which includes data concerning production, electricity installed capacity, turbine characteristics and tidal ranges. A very good correlation was found between the results of the numerical model and those reported in various technical reports. [Spanish] Se presenta una metodologia que permite estimar de manera rapida y sencilla el potencial de energia que puede ser extraido a traves de una planta mareomotriz. La evaluacion se realiza utilizando un nomograma normalizado que es funcion del area del embalse versus la capacidad electrica instalada, para asi obtener el potencial energetico en una zona en particular. Los resultados contemplan dos formas de operacion, una llamada en flujo y otra en flujo-reflujo, dos esquemas de embalse (sencillo y doble embalse). Para la elaboracion del nomograma normalizado se utilizaron resultados numericos de la simulacion de multiples plantas mareomotrices bajo diferentes escenarios durante un ano de operacion. Los escenarios

  3. Analysis and evaluation of the main factors that influence the growing of the electrical power consumption in the national electrical sector, period 2000-2005; Analisis y evaluacion de los principales factores que influyen en el crecimiento del consumo de energia electrica en el sector electrico nacional, periodo 2000-2005

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar Luna, Luis Miguel

    2008-06-15

    de potencia (CUFP). Ademas, se desarrolla en esta tesis las ecuaciones utilizadas en el Jacobiano del metodo Newton-Raphson, para resolver flujos de potencia incluyendo los dispositivos SIFLETCA. Se muestra diferentes aplicaciones que se tienen al instalar un dispositivo, tales como prevencion de flujos en anillo, barrera electronica, incremento en la capacidad de transmision y especificacion del flujo de potencia en lineas de transmision. Por otra parte, se desarrolla en la tesis un analisis de sensibilidades de un sistema de potencia en estado estacionario. Tambien se proponen en la tesis los parametros de control para los cuales se calcula las sensibilidades. Asimismo, se utiliza un indice de desempeno para medir el grado de congestion de un sistema electrico. Al calcular las sensibilidades se utiliza los resultados obtenidos de los flujos de potencia. Se usa 4 redes electricas para encontrar donde se debe situar cada dispositivo SIFLETCA para reducir la congestion en el sistema. Tambien, se compara el metodo desarrollado en la tesis con un metodo de sensibilidades que emplea flujos de CD para validacion y mostrar las ventajas de usar el metodo Newton en flujos de potencia.

  4. Clean generation of electric energy; Generacion limpia de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, Juan M.; Torres, Emmanuel [Centro de Investigacion y de Estudios Avanzados (CINVESTAV), Unidad Guadalajara (Mexico)

    2006-10-15

    This article deals on the existing alternatives of renewable energy for generation of electricity free from polluting sequels within the Mexican territory and presents a global overview on the electricity generation in Mexico. Wind power, hydraulic energy, biomass, photovoltaic and fuel cells are sources of renewable energy that could contribute to Mexico's sustainable development, for this reason it is discussed on the main sources of renewable energy in Mexico - solar and wind energy, mini-hydraulic, biomass and geothermal -, on their development and evolution, cost, insertion projects and obstacles for their correct development in this country. [Spanish] Este articulo versa sobre las alternativas de energia renovable existentes para una generacion de electricidad libre de secuelas contaminantes dentro del territorio mexicano y presenta un panorama global sobre la generacion de electricidad en Mexico. La energia eolica, hidraulica, biomasa, fotovoltaica y las celdas de combustible son fuentes de energia renovable que podrian contribuir al desarrollo sustentable de Mexico, por esto se arguye sobre las principales fuentes de energia renovable en Mexico -energia solar, eolica, minihidraulica, biomasa y geotermia-, sobre su desarrollo y evolucion, costo, proyectos de insercion y obstaculos para su correcto desarrollo en ese pais.

  5. Preferred external power supplies; Fuentes electricas preferentes exteriores

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Anton, L.

    2010-07-01

    In June 2008 ANAV and ENDESA DISTRIBUCION (EDE) undertook a joint study of Asco NPP Preferred External Power Supplies (PEPSs) to check the number of lines or power supplies to the 110 kV substation at Asco that met the criteria defined in the power supply regulations applicable to Asco NPP and primarily to confirm compliance with IEEE 765-2006 standard. (Author).

  6. Worker flag. Independent Electrical Policy; Bandera Obrera. Politica Electrica Independiente

    Energy Technology Data Exchange (ETDEWEB)

    Bahen, D [Sindicato Unico de Trabajadores de la Industria Nuclear, Salazar, Estado de Mexico C.P. 52045 (Mexico)

    2000-07-01

    This work analyses the initiative of privatization of the Mexican Electric Industry and also it is showed the incoherence of this mistaken proposal. Along the same line is analysed tthe situation of the National Electric Sector and the working process for the distinct types of electric generation just as the syndical and labor situations. In consequence it is proposed an Independent Electrical Policy, which includes the integration of the Nationalized Electric Industry, the syndical union and the Unique Collective Contract. The purpose of this work is to contribute to the success of the electrical and nuclear struggle always maintaining in rising position the red flag of the proletariat. The author considers that the privatization means mercantilization of the human necessities. The privatization is not inevitable at condition of to exercise consequently the political actions necessary through alternatives includes: the worker control of production, research, and the National Electric strike. (Author)

  7. Plant Host Finding by Parasitic Plants: A New Perspective on Plant to Plant Communication

    OpenAIRE

    Mescher, Mark C; Runyon, Justin B; De Moraes, Consuelo M

    2006-01-01

    Plants release airborne chemicals that can convey ecologically relevant information to other organisms. These plant volatiles are known to mediate a large array of, often complex, interactions between plants and insects. It has been suggested that plant volatiles may have similar importance in mediating interactions among plant species, but there are few well-documented examples of plant-to-plant communication via volatiles, and the ecological significance of such interactions has been much d...

  8. Nuclear power plants

    International Nuclear Information System (INIS)

    1985-01-01

    Data concerning the existing nuclear power plants in the world are presented. The data was retrieved from the SIEN (Nuclear and Energetic Information System) data bank. The information are organized in table forms as follows: nuclear plants, its status and type; installed nuclear power plants by country; nuclear power plants under construction by country; planned nuclear power plants by country; cancelled nuclear power plants by country; shut-down nuclear power plants by country. (E.G.) [pt

  9. LNG plant combined with power plant

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, I; Kikkawa, Y [Chiyoda Chemical Engineering and Construction Co. Ltd., Tokyo (Japan)

    1997-06-01

    The LNG plant consumers a lot of power of natural gas cooling and liquefaction. In some LNG plant location, a rapid growth of electric power demand is expected due to the modernization of area and/or the country. The electric power demand will have a peak in day time and low consumption in night time, while the power demand of the LNG plant is almost constant due to its nature. Combining the LNG plant with power plant will contribute an improvement the thermal efficiency of the power plant by keeping higher average load of the power plant, which will lead to a reduction of electrical power generation cost. The sweet fuel gas to the power plant can be extracted from the LNG plant, which will be favorable from view point of clean air of the area. (Author). 5 figs.

  10. LNG plant combined with power plant

    International Nuclear Information System (INIS)

    Aoki, I.; Kikkawa, Y.

    1997-01-01

    The LNG plant consumers a lot of power of natural gas cooling and liquefaction. In some LNG plant location, a rapid growth of electric power demand is expected due to the modernization of area and/or the country. The electric power demand will have a peak in day time and low consumption in night time, while the power demand of the LNG plant is almost constant due to its nature. Combining the LNG plant with power plant will contribute an improvement the thermal efficiency of the power plant by keeping higher average load of the power plant, which will lead to a reduction of electrical power generation cost. The sweet fuel gas to the power plant can be extracted from the LNG plant, which will be favorable from view point of clean air of the area. (Author). 5 figs

  11. Design, test and start up of a cleaning system for the moderator tank bottom of Atucha I Nuclear Power Plant

    International Nuclear Information System (INIS)

    Duca, J.; Gerber, O.; Ibero, M.; Riga, N.

    1989-01-01

    In order to perform the cleaning of the moderator tank bottom, during the repair of the Atucha I nuclear power plant (CNA I) failure, the Empresa Nuclear Argentina de Centrales Electricas (ENACE S.A.) designed a system with the following requirements (asked by CNA I): a) To aspirate and retain free solid particles, uranium dioxide pellets and coolant channels isolations (foils) of minor size settled at the moderator tank bottom, being the reactor at middle loop state. b) To allow a radially cleaning up to 1.4 m from the extracted channel. c) To design a lay-out attaining the ALARA dose exposure. The designed system basically consists in: a) Flexible intake for suction: allows the movement inside the moderator tank and provides the adequate speed to raise the particles. b) Filter: retains the aspirated particles, pellets and foils. Its capacity is 1.8 dm 3 and the minimum size of retained particles is 200 m. The ALARA dose exposure concept is attained due to that the filter is located inside the moderator tank. c) Filtering column: contains the filter and allows the entrance of the extraction and exchange tool (for the flexible intake and filter). d) Suction hose: connects the filtering column with the pump. Its flexibility allows its use in any channel maintaining the same positions of the discharge pump and the return piping. e) Discharge pump: it is a canned centrifugal pump with low-low net positive suction head. f) Return piping: discharges the filtered water into the moderator tank. The system fulfilled satisfactorily all requirements during its operation. (Author)

  12. Plant host finding by parasitic plants: a new perspective on plant to plant communication.

    Science.gov (United States)

    Mescher, Mark C; Runyon, Justin B; De Moraes, Consuelo M

    2006-11-01

    Plants release airborne chemicals that can convey ecologically relevant information to other organisms. These plant volatiles are known to mediate a large array of, often complex, interactions between plants and insects. It has been suggested that plant volatiles may have similar importance in mediating interactions among plant species, but there are few well-documented examples of plant-to-plant communication via volatiles, and the ecological significance of such interactions has been much debated. To date, nearly all studies of volatile-mediated interactions among plant species have focused on the reception of herbivore-induced volatiles by neighboring plants. We recently documented volatile effects in another system, demonstrating that the parasitic plant Cuscuta pentagona uses volatile cues to locate its hosts. This finding may broaden the discussion regarding plant-to-plant communication, and suggests that new classes of volatile-meditated interactions among plant species await discovery.

  13. Plant host finding by parasitic plants: A new perspective on plant to plant communication

    Science.gov (United States)

    Mark C. Mescher; Justin B. Runyon; Consuelo M. De Moraes

    2006-01-01

    Plants release airborne chemicals that can convey ecologically relevant information to other organisms. These plant volatiles are known to mediate a large array of, often complex, interactions between plants and insects. It has been suggested that plant volatiles may have similar importance in mediating interactions among plant species, but there are few well-...

  14. Methodology to establish the profile that defines a meta-specification that applies to distribution substations - Mexico case based on norm IEC-61850; Metodologia para establecer el perfil que define una meta-especificacion que aplica a subestaciones de distribucion -caso Mexico- basada en la norma IEC-61850

    Energy Technology Data Exchange (ETDEWEB)

    Picazo Blanquel, Cuitlahuac; Chairez Campos Carlos; Garcia Hernandez, Joaquin; Godinez Enriquez, Hebert; Poujol Galvan, Francisco C.; Suarez Cerda, Dionisio A. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Villalobos Ramos, Andres; LLamas Gonzalez, Rosa E. [Comision Federal de Electricidad (Mexico); Samitier Otero, Carlos [Global Networking Engineering (Spain)

    2010-07-01

    In this article is presented a case of study of automation of electrical substations of Comision Federal de Electricidad (CFE) of Mexico, in which the Norm IEC-61850 has been taken as reference. The case of study consists of defining a metaspecification for the protection, control, measurement and communication systems required by the substations of electrical distribution. For the development the obtained previous experience in the development of a bequeathed system SA, norm IEC61850 has been taken as reference, as well as the experiences documented in the Instituto de Investigaciones Electricas (IIE), the Comision Federal de Electricidad (CFE) and Global Networking Engineering (GNE), Spain. This way, the obtained result is the metaspecification, which establishes the application of the control, protective equipment and measurement under the interoperability concepts, as well as the automation functions of substations applied in the intelligent networks (REI's). The methodology put into practice includes the design of the system architecture (SAS), the operation philosophy, the topology of the communications network, the data modeling one with logical nodes that include data types and classes of common data (CDC), transference of information, and administration of the archives ICD, SSD, SCD, and CID. [Spanish] En este articulo se presenta un caso de estudio de automatizacion de subestaciones electricas de la Comision Federal de Electricidad (CFE) de Mexico, en el cual se ha tomado como referencia la norma IEC-61850. El caso de estudio consiste en definir una metaespecificacion para los sistemas proteccion, control, medicion y comunicaciones requeridos por las subestaciones de distribucion electrica. Para el desarrollo se ha tomado como referencia la experiencia previa obtenida en el desarrollo de un sistema SA legado, la norma IEC61850, asi como las experiencias documentadas en el Instituto de Investigaciones Electricas (IIE), la Comision Federal de

  15. Technical economic feasibility study for the implementation of a nuclear power plant for the production of electricity in Colombia; Estudio de factibilidad tecnico economica para la implementacion de una central de energia nuclear para la produccion de energia electrica en Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Gonzales, David E.; Bolanos, Hernan G.; Mayorga, Manuel A.; Rodriguez, Edwin A., E-mail: david_egO@yahoo.es, E-mail: hernanbolaos@yahoo.com.ar, E-mail: alejo_mayorga@yahoo.com, E-mail: edwin.rodriguez@distoyota.com.co [Escuela Colombiana de Carreras Industriales (ECCI), Bogota (Colombia). Grupo de Investigacion GIATME

    2013-07-01

    A study on the technical and economic feasibility will be used to implement a nuclear power in Colombia to generate electricity. To this will be searched if there are previous studies on this topic and what they concluded. The manner in which power is supplied will be discussed in a national level nowadays, its strengths and weaknesses. It will be investigated the legal norms that exists in the country on nuclear power and renewable energy sources, the standards established at world level, the nuclear accidents and the great examples. Providers will be sought on the world market nuclear equipment which serve to this purpose and the technical characteristics of these equipment will be discussed. The type of fuel used in nuclear reactors, its origin, method of production, specifications, availability and long-term and safe handling and final disposal are considered. safe handling of this technology and policy or international rules that will studied.

  16. Kansas Power Plants

    Data.gov (United States)

    Kansas Data Access and Support Center — The Kansas Power Plants database depicts, as point features, the locations of the various types of power plant locations in Kansas. The locations of the power plants...

  17. Gender in Plants

    Indian Academy of Sciences (India)

    What is the difference between plant sex and plant gender? Why does stress .... environmental sex determination is often predictable. Sunlit patches favour .... ensures that these self-incompatible plants receive cross-pollen only. i emporal ...

  18. Engineered Plants as Biosensors

    National Research Council Canada - National Science Library

    Stewart, C

    2003-01-01

    The aim of the research was the creation of a model biosensing plant that could detect plant diseases and to characterize the utility of laser induced fluorescence imaging for detecting the inducible (LIFI) plant signal...

  19. Plant stress signalling: understanding and exploiting plant-plant interactions.

    Science.gov (United States)

    Pickett, J A; Rasmussen, H B; Woodcock, C M; Matthes, M; Napier, J A

    2003-02-01

    When plants are attacked by insects, volatile chemical signals can be released, not only from the damaged parts, but also systemically from other parts of the plant and this continues after cessation of feeding by the insect. These signals are perceived by olfactory sensory mechanisms in both the herbivorous insects and their parasites. Molecular structures involved can be characterized by means of electrophysiological assays, using the insect sensory system linked to chemical analysis. Evidence is mounting that such signals can also affect neighbouring intact plants, which initiate defence by the induction of further signalling systems, such as those that increase parasitoid foraging. Furthermore, insect electrophysiology can be used in the identification of plant compounds having effects on the plants themselves. It has been found recently that certain plants can release stress signals even when undamaged, and that these can cause defence responses in intact plants. These discoveries provide the basis for new crop protection strategies, that are either delivered by genetic modification of plants or by conventionally produced plants to which the signal is externally applied. Delivery can also be made by means of mixed seed strategies in which the provoking and recipient plants are grown together. Related signalling discoveries within the rhizosphere seem set to extend these approaches into new ways of controlling weeds, by exploiting the elusive potential of allelopathy, but through signalling rather than by direct physiological effects.

  20. Plants get sick too!

    Science.gov (United States)

    Although many people may never have given consideration to plant health, plants can suffer from a wide range of diseases. These plant diseases are caused by micro-organisms, including bacteria, fungi, and viruses. The audience will be introduced to short case studies of several plant diseases that m...

  1. Plant extraction process

    DEFF Research Database (Denmark)

    2006-01-01

    A method for producing a plant extract comprises incubating a plant material with an enzyme composition comprising a lipolytic enzyme.......A method for producing a plant extract comprises incubating a plant material with an enzyme composition comprising a lipolytic enzyme....

  2. Radioactive uptake by plants

    Energy Technology Data Exchange (ETDEWEB)

    Horak, O

    1986-01-01

    The fundamentals of radionuclide uptake by plants, both by leaves and roots are presented. Iodine, cesium, strontium and ruthenium are considered and a table of the measured concentrations in several agricultural plants shortly after the Chernobyl accident is presented. Another table gives the Cs and Sr transfer factors soil plants for some plants. By using them estimates of future burden can be obtained.

  3. Plant Biology Science Projects.

    Science.gov (United States)

    Hershey, David R.

    This book contains science projects about seed plants that deal with plant physiology, plant ecology, and plant agriculture. Each of the projects includes a step-by-step experiment followed by suggestions for further investigations. Chapters include: (1) "Bean Seed Imbibition"; (2) "Germination Percentages of Different Types of Seeds"; (3)…

  4. Plants' essential chemical elements

    Science.gov (United States)

    Kevin T. Smith

    2007-01-01

    Every garden center and hardware store sells fertilizer guaranteed to "feed" plants. In a strict sense, we can't feed plants. Food contains an energy source. Green plants capture solar energy and make their own food through photosynthesis! Photosynthesis and other metabolic processes require chemical elements in appropriate doses for plants to survive...

  5. Plant Research '75

    Energy Technology Data Exchange (ETDEWEB)

    1975-01-01

    Research is reported on stomatal regulation of the gas exchanges between plant and environment; inhibitory effects in flower formation; plant growth and development through hormones; hormone action; development and nitrogen fixation in algae; primary cell wall glycoprotein ectensin; enzymic mechanisms and control of polysaccharide and glycoprotein synthesis; molecular studies of membrane studies; sensory transduction in plants; regulation of formation of protein complexes and enzymes in higher plant cell and mechanism of sulfur dioxide toxicity in plants. (PCS)

  6. PLANT BIOPRINTING: NOVEL PERSPECTIVE FOR PLANT BIOTECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Adhityo WICAKSONO

    2015-12-01

    Full Text Available Bioprinting is a technical innovation that has revolutionized tissue engineering. Using conventional printer cartridges filled with cells as well as a suitable scaffold, major advances have been made in the biomedical field, and it is now possible to print skin, bones, blood vessels, and even organs. Unlike animal systems, the application of bioprinting in simple plant tissue cells is still in a nascent phase and has yet to be studied. One major advantage of plants is that all living parts are reprogrammable in the form of totipotent cells. Plant bioprinting may improve scientists’understanding of plant shape and morphogenesis, and could serve for the mass production of desired tissues or plants, or even the production of plant-based biomaterial for industrial uses. This perspectives paper explores these possibilities using knowledge on what is known about bioprinting in other biosystems.

  7. Performance study of a combined cycle power plant with integral gasification; Estudio del desempeno de una planta de potencia de ciclo combinado con gasificacion integral

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Rocha, Jose Clemente

    2007-04-15

    At world-wide level, in the last decade the interest has been increased in the use of petroleum coke as fuel in the clean generation of energy applying the gasification technology. This interest is mainly due to the increment the production of petroleum coke as a result of processing larger volumes of crude processed in the refineries and to the increment in the yield of products with high added value, such as turbo-fuel or diesel, among others. With the new reconfiguration of the Mexican refinery of Cd. Madero and Cadereyta and soon with the completion of the reconfiguration of the Minatitlan, Veracruz refinery, larger amounts of coke will be produced, with the possibility of using it, by means of the appropriate gasification technology, to produce a clean synthetic gas (gasl) with the appropriate energy characteristic to be used as fuel in a combined cycle existing in Mexico. In Mexico the possibilities of generation of electrical energy from the utilization of petroleum coke have been considered departing from the use of petroleum coke using the gasification technology or using fluidized bed steam generators as is the case of the power plant TEG in Taquin, San Luis Potosi. Such is the fact, that at the moment PEMEX Refinacion, has completed the project of constructing in Tuxpan, Veracruz a crude processing refinery of Mayan crude with a high sulfur content and next to the Tuxpan Power Plant, being contemplated the possibility of applying the concept of combined cycle with integrated gasification (CCGI); with this infrastructure it will be possible to consume the coke generated by the Mexican refineries. The expected electrical generation is of 500 MW, of which 100 MW will be for own consumption of the refinery and 400 MW free to cover the electrical energy demand within the North East and Center Zone of the country. The petroleum coke derived from the refineries of the country can be used for the clean generation of electricity by means of its gasification and

  8. Plutonium Plant, Trombay

    International Nuclear Information System (INIS)

    Yadav, J.S.; Agarwal, K.

    2017-01-01

    The journey of Indian nuclear fuel reprocessing started with the commissioning of Plutonium Plant (PP) at Trombay on 22"n"d January, 1965 with an aim to reprocess the spent fuel from research reactor CIRUS. The basic process chosen for the plant was Plutonium Uranium Reduction EXtraction (PUREX) process. In seventies, the plant was subjected to major design modifications and replacement of hardware, which later met the additional demand from research reactor DHRUVA. The augmented plutonium plant has been operating since 1983. Experience gained from this plant was very much helpful to design future reprocessing plant in the country

  9. Better plants through mutations

    International Nuclear Information System (INIS)

    1988-01-01

    This is a public relations film describing problems associated with the genetic improvement of crop plants through induced mutations. Mutations are the ultimate source of genetic variation in plants. Mutation induction is now established as a practical tool in plant breeding. The Joint FAO/IAEA Division and the IAEA's laboratory at Seibersdorf have supported research and practical implementation of mutation breeding of both seed propagated and vegetatively propagated plants. Plant biotechnology based on in vitro culture and recombinant DNA technology will make a further significant contribution to plant breeding

  10. Plant Phenotype Characterization System

    Energy Technology Data Exchange (ETDEWEB)

    Daniel W McDonald; Ronald B Michaels

    2005-09-09

    This report is the final scientific report for the DOE Inventions and Innovations Project: Plant Phenotype Characterization System, DE-FG36-04GO14334. The period of performance was September 30, 2004 through July 15, 2005. The project objective is to demonstrate the viability of a new scientific instrument concept for the study of plant root systems. The root systems of plants are thought to be important in plant yield and thus important to DOE goals in renewable energy sources. The scientific study and understanding of plant root systems is hampered by the difficulty in observing root activity and the inadequacy of existing root study instrumentation options. We have demonstrated a high throughput, non-invasive, high resolution technique for visualizing plant root systems in-situ. Our approach is based upon low-energy x-ray radiography and the use of containers and substrates (artificial soil) which are virtually transparent to x-rays. The system allows us to germinate and grow plant specimens in our containers and substrates and to generate x-ray images of the developing root system over time. The same plant can be imaged at different times in its development. The system can be used for root studies in plant physiology, plant morphology, plant breeding, plant functional genomics and plant genotype screening.

  11. Plant tissue culture techniques

    Directory of Open Access Journals (Sweden)

    Rolf Dieter Illg

    1991-01-01

    Full Text Available Plant cell and tissue culture in a simple fashion refers to techniques which utilize either single plant cells, groups of unorganized cells (callus or organized tissues or organs put in culture, under controlled sterile conditions.

  12. Plant Tissue Culture

    Indian Academy of Sciences (India)

    Admin

    Plant tissue culture is a technique of culturing plant cells, tissues and organs on ... working methods (Box 2) and discovery of the need for B vita- mins and auxins for ... Kotte (Germany) reported some success with growing isolated root tips.

  13. Fertilization in Flowering Plants

    Indian Academy of Sciences (India)

    IAS Admin

    Ecology and the Environ- ment, Bengaluru as ... remaining plants, it is an abiotic agent (abiotic pollination), .... tion was slow until the origin of flowering plants and evolution of ..... Although pollination is generally a mutual interaction in a major-.

  14. Plant proton pumps

    DEFF Research Database (Denmark)

    Gaxiola, Roberto A.; Palmgren, Michael Gjedde; Schumacher, Karin

    2007-01-01

    Chemiosmotic circuits of plant cells are driven by proton (H+) gradients that mediate secondary active transport of compounds across plasma and endosomal membranes. Furthermore, regulation of endosomal acidification is critical for endocytic and secretory pathways. For plants to react...

  15. Terrestrial plant methane production

    DEFF Research Database (Denmark)

    Mikkelsen, Teis Nørgaard; Bruhn, Dan; Møller, Ian M.

    We evaluate all experimental work published on the phenomenon of aerobic methane (CH4) generation in terrestrial plants. We conclude that the phenomenon is true. Four stimulating factors have been observed to induce aerobic plant CH4 production, i.e. cutting injuries, increasing temperature...... the aerobic methane emission in plants. Future work is needed for establishing the relative contribution of several proven potential CH4 precursors in plant material....

  16. Plant aquaporins: roles in plant physiology.

    Science.gov (United States)

    Li, Guowei; Santoni, Véronique; Maurel, Christophe

    2014-05-01

    Aquaporins are membrane channels that facilitate the transport of water and small neutral molecules across biological membranes of most living organisms. Here, we present comprehensive insights made on plant aquaporins in recent years, pointing to their molecular and physiological specificities with respect to animal or microbial counterparts. In plants, aquaporins occur as multiple isoforms reflecting a high diversity of cellular localizations and various physiological substrates in addition to water. Of particular relevance for plants is the transport by aquaporins of dissolved gases such as carbon dioxide or metalloids such as boric or silicic acid. The mechanisms that determine the gating and subcellular localization of plant aquaporins are extensively studied. They allow aquaporin regulation in response to multiple environmental and hormonal stimuli. Thus, aquaporins play key roles in hydraulic regulation and nutrient transport in roots and leaves. They contribute to several plant growth and developmental processes such as seed germination or emergence of lateral roots. Plants with genetically altered aquaporin functions are now tested for their ability to improve plant resistance to stresses. This article is part of a Special Issue entitled Aquaporins. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Plants under dual attack

    NARCIS (Netherlands)

    Ponzio, C.A.M.

    2016-01-01

    Though immobile, plants are members of complex environments, and are under constant threat from a wide range of attackers, which includes organisms such as insect herbivores or plant pathogens. Plants have developed sophisticated defenses against these attackers, and include chemical responses

  18. Growing Plants and Minds

    Science.gov (United States)

    Presser, Ashley Lewis; Kamdar, Danae; Vidiksis, Regan; Goldstein, Marion; Dominguez, Ximena; Orr, Jillian

    2017-01-01

    Many preschool classrooms explore plant growth. However, because many plants take a long time to grow, it is often hard to facilitate engagement in some practices (i.e., since change is typically not observable from one day to another, children often forget their prior predictions or cannot recall what plants looked like days or weeks earlier).…

  19. Fundaments of plant cybernetics.

    Science.gov (United States)

    Zucconi, F

    2001-01-01

    A systemic approach is proposed for analyzing plants' physiological organization and cybernesis. To this end, the plant is inspected as a system, starting from the integration of crown and root systems, and its impact on a number of basic epigenetic events. The approach proves to be axiomatic and facilitates the definition of the principles behind the plant's autonomous control of growth and reproduction.

  20. Plant or Animal?

    Science.gov (United States)

    Bowman, Frank; Matthews, Catherine E.

    1996-01-01

    Presents activities that use marine organisms with plant-like appearances to help students build classification skills and illustrate some of the less obvious differences between plants and animals. Compares mechanisms by which sessile plants and animals deal with common problems such as obtaining energy, defending themselves, successfully…

  1. Small hydroelectric power plants

    International Nuclear Information System (INIS)

    Helgesen, Boerre

    2002-01-01

    Small hydroelectric power plants are power plants of 1 - 10 MW. For a supplier, this is an unnatural limit. A more natural limit involves compact engine design and simplified control system. The article discusses most of the engine and electrotechnical aspects in the development, construction and operation of such a plant

  2. Recognizing Plant Defense Priming.

    Science.gov (United States)

    Martinez-Medina, Ainhoa; Flors, Victor; Heil, Martin; Mauch-Mani, Brigitte; Pieterse, Corné M J; Pozo, Maria J; Ton, Jurriaan; van Dam, Nicole M; Conrath, Uwe

    2016-10-01

    Defense priming conditions diverse plant species for the superinduction of defense, often resulting in enhanced pest and disease resistance and abiotic stress tolerance. Here, we propose a guideline that might assist the plant research community in a consistent assessment of defense priming in plants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Plant Physiology in Greenhouses

    NARCIS (Netherlands)

    Heuvelink, E.; Kierkels, T.

    2015-01-01

    Since 2004 Ep Heuvelink and Tijs Kierkels have been writing a continuing series of plant physiology articles for the Dutch horticultural journal Onder Glas and the international edition In Greenhouses. The book Plant Physiology in Greenhouses consists of 50 of their plant physiology articles. The

  4. Plants and people

    Science.gov (United States)

    Kathryn Lynch

    2012-01-01

    Salal! Salmonberries! Sword ferns! The Northwest is home to a great number of native plant species that humans have used for centuries. Sadly, many local children are unaware of the history and culture connecting people and plants. Yet, from the beginning of time, plants have provided us food, medicine, and material for clothing, shelter, transportation, decoration,...

  5. Plant Systems Biology (editorial)

    Science.gov (United States)

    In June 2003, Plant Physiology published an Arabidopsis special issue devoted to plant systems biology. The intention of Natasha Raikhel and Gloria Coruzzi, the two editors of this first-of-its-kind issue, was ‘‘to help nucleate this new effort within the plant community’’ as they considered that ‘‘...

  6. Plants of the Bayshore.

    Science.gov (United States)

    Bachle, Leo; And Others

    This field guide gives pictures and descriptions of plants that can be found along the San Francisco Bayshore, especially along the Hayward shoreline. The plants are divided into three categories, those of the mud-flat zone, the drier zone, and the levee zone. Eighteen plants are represented in all. The guide is designed to be used alone, with an…

  7. TRANSGENIC PLANT CONTAINMENT

    Science.gov (United States)

    The new technology using plant genetics to produce chemicals, pharmaceuticals, and therapeuitics in a wide array of new plant forms requires sufficient testing to ensure that these new plant introductions are benign in the environment. A recent effort to provide necessary guidan...

  8. Plant Breeding Goes Microbial

    NARCIS (Netherlands)

    Wei, Zhong; Jousset, Alexandre

    Plant breeding has traditionally improved traits encoded in the plant genome. Here we propose an alternative framework reaching novel phenotypes by modifying together genomic information and plant-associated microbiota. This concept is made possible by a novel technology that enables the

  9. Plant innate immunity

    Indian Academy of Sciences (India)

    Plants are invaded by an array of pathogens of which only a few succeed in causing disease. The attack by others is countered by a sophisticated immune system possessed by the plants. The plant immune system is broadly divided into two, viz. microbial-associated molecular-patterns-triggered immunity (MTI) and ...

  10. Diagnosing plant problems

    Science.gov (United States)

    Cheryl A. Smith

    2008-01-01

    Diagnosing Christmas tree problems can be a challenge, requiring a basic knowledge of plant culture and physiology, the effect of environmental influences on plant health, and the ability to identify the possible causes of plant problems. Developing a solution or remedy to the problem depends on a proper diagnosis, a process that requires recognition of a problem and...

  11. Hydroelectric Power Plants Dobsina

    International Nuclear Information System (INIS)

    Majercak, V.; Srenkelova, Z.; Kristak, J.G.

    1997-01-01

    In this brochure the Hydroelectric Power Plants Dobsina, (VED), subsidiary of the utility Slovenske Elektrarne, a.s. (Slovak Electric, plc. Bratislava) are presented. VED is mainly aimed at generating peak-load electrical energy and maintenance of operational equipment. Reaching its goals, company is first of all focused on reliability of production, economy and effectiveness, keeping principles of work safety and industry safety standards and also ecology. VED operates eight hydroelectric power plants, from which PVE Ruzin I and PVE Dobsina I are pump storage ones and they are controlled directly by the Slovak Energy Dispatch Centre located in Zilina thought the system LS 3200. Those power plants participate in secondary regulation of electrical network of Slovakia. They are used to compensate balance in reference to foreign electrical networks and they are put into operation independently from VED. Activity of the branch is focused mainly on support of fulfilment of such an important aim as electric network regulation. Beginnings of the subsidiary Hydroelectric Power Plants Dobsina are related to the year of 1948. After commissioning of the pump storage Hydroelectric Power Plants Dobsina in 1953, the plant started to carry out its mission. Since that time the subsidiary has been enlarged by other seven power plants, through which it is fulfilling its missions nowadays. The characteristics of these hydroelectric power plants (The pump-storage power plant Dobsina, Small hydroelectric power plant Dobsina II, Small hydroelectric power plant Rakovec, Small hydroelectric power plant Svedlar, Hydroelectric power plant Domasa, The pump-storage power plant Ruzin, and Small hydroelectric power plant Krompachy) are described in detail. Employees welfare and public relations are presented

  12. Multinationals and plant survival

    DEFF Research Database (Denmark)

    Bandick, Roger

    2010-01-01

    The aim of this paper is twofold: first, to investigate how different ownership structures affect plant survival, and second, to analyze how the presence of foreign multinational enterprises (MNEs) affects domestic plants’ survival. Using a unique and detailed data set on the Swedish manufacturing...... sector, I am able to separate plants into those owned by foreign MNEs, domestic MNEs, exporting non-MNEs, and purely domestic firms. In line with previous findings, the result, when conditioned on other factors affecting survival, shows that foreign MNE plants have lower survival rates than non......-MNE plants. However, separating the non-MNEs into exporters and non-exporters, the result shows that foreign MNE plants have higher survival rates than non-exporting non-MNEs, while the survival rates of foreign MNE plants and exporting non-MNE plants do not seem to differ. Moreover, the simple non...

  13. Plant life management

    International Nuclear Information System (INIS)

    Charbonneau, S.; Framatome, J.B.

    1992-01-01

    Plant life assessment and extension studies have been performed by numerous companies all over the world. Critical equipment has been identified as well as various degradation mechanisms involved in the plant aging process. Nowadays one has to think what to implement to improve the existing situation in the Nuclear Power Plant (NPP). FRAMATOME has undertaken this thought process in order to find the right answers and bring them to utilities facing either critical concern for plant life extension or the problem of management of power plant potential longevity. This is why we prepared a Plant Life Improvement Action Plan, comprising 10 (ten) major items described hereafter using examples of work performed by FRAMATOME for its utility customers desiring to manage the lives of their plants, both in France with EDF and abroad

  14. Photochemical smog and plants

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, T.

    1974-07-01

    Surveys of plant damage due to photochemical smog are summarized. The components of smog which appear to be responsible for plant damage include ozone and peroxyacyl nitrates. Their phytotoxic effects are much greater than those due to sulfur oxides. Damage surveys since 1970 reveal the following symptoms appearing on herbaceous plants (morning glory, cocks comb, dahlia, knotweed, petunia, chickweed, Welsh onion, spinach, Chinese cabbage, chard, taro): yellowish-white leaf discoloration, white and brown spots on matured leaves, and silvering of the lower surfaces of young leaves. Symptoms which appear on arboraceous plants such as zelkova, poplar, ginkgo, planetree, rose mallow, magnolia, pine tree, and rhododendron include early yellowing and reddening, white or brown spots, and untimely leaf-fall. The above plants are now utilized as indicator plants of photochemical smog. Surveys covering a broad area of Tokyo and three other prefectures indicate that plant damage due to photochemical smog extends to relatively unpolluted areas.

  15. Plant Physiology and Development

    DEFF Research Database (Denmark)

    Taiz, Lincoln; Zeiger, Eduardo; Møller, Ian Max

    Throughout its twenty-two year history, the authors of Plant Physiology have continually updated the book to incorporate the latest advances in plant biology and implement pedagogical improvements requested by adopters. This has made Plant Physiology the most authoritative, comprehensive......, and widely used upper-division plant biology textbook. In the Sixth Edition, the Growth and Development section (Unit III) has been reorganized and expanded to present the complete life cycle of seed plants from germination to senescence. In recognition of this enhancement, the text has been renamed Plant...... Physiology and Development. As before, Unit III begins with updated chapters on Cell Walls and Signals and Signal Transduction. The latter chapter has been expanded to include a discussion of major signaling molecules, such as calcium ions and plant hormones. A new, unified chapter entitled Signals from...

  16. Reassessing apoptosis in plants.

    Science.gov (United States)

    Dickman, Martin; Williams, Brett; Li, Yurong; de Figueiredo, Paul; Wolpert, Thomas

    2017-10-01

    Cell death can be driven by a genetically programmed signalling pathway known as programmed cell death (PCD). In plants, PCD occurs during development as well as in response to environmental and biotic stimuli. Our understanding of PCD regulation in plants has advanced significantly over the past two decades; however, the molecular machinery responsible for driving the system remains elusive. Thus, whether conserved PCD regulatory mechanisms include plant apoptosis remains enigmatic. Animal apoptotic regulators, including Bcl-2 family members, have not been identified in plants but expression of such regulators can trigger or suppress plant PCD. Moreover, plants exhibit nearly all of the biochemical and morphological features of apoptosis. One difference between plant and animal PCD is the absence of phagocytosis in plants. Evidence is emerging that the vacuole may be key to removal of unwanted plant cells, and may carry out functions that are analogous to animal phagocytosis. Here, we provide context for the argument that apoptotic-like cell death occurs in plants.

  17. Safe genetically engineered plants

    Energy Technology Data Exchange (ETDEWEB)

    Rosellini, D; Veronesi, F [Dipartimento di Biologia Vegetale e Biotecnologie Agroambientali e Zootecniche, Universita degli Studi di Perugia, Borgo XX giugno 74, 06121 Perugia (Italy)

    2007-10-03

    The application of genetic engineering to plants has provided genetically modified plants (GMPs, or transgenic plants) that are cultivated worldwide on increasing areas. The most widespread GMPs are herbicide-resistant soybean and canola and insect-resistant corn and cotton. New GMPs that produce vaccines, pharmaceutical or industrial proteins, and fortified food are approaching the market. The techniques employed to introduce foreign genes into plants allow a quite good degree of predictability of the results, and their genome is minimally modified. However, some aspects of GMPs have raised concern: (a) control of the insertion site of the introduced DNA sequences into the plant genome and of its mutagenic effect; (b) presence of selectable marker genes conferring resistance to an antibiotic or an herbicide, linked to the useful gene; (c) insertion of undesired bacterial plasmid sequences; and (d) gene flow from transgenic plants to non-transgenic crops or wild plants. In response to public concerns, genetic engineering techniques are continuously being improved. Techniques to direct foreign gene integration into chosen genomic sites, to avoid the use of selectable genes or to remove them from the cultivated plants, to reduce the transfer of undesired bacterial sequences, and make use of alternative, safer selectable genes, are all fields of active research. In our laboratory, some of these new techniques are applied to alfalfa, an important forage plant. These emerging methods for plant genetic engineering are briefly reviewed in this work.

  18. Safe genetically engineered plants

    International Nuclear Information System (INIS)

    Rosellini, D; Veronesi, F

    2007-01-01

    The application of genetic engineering to plants has provided genetically modified plants (GMPs, or transgenic plants) that are cultivated worldwide on increasing areas. The most widespread GMPs are herbicide-resistant soybean and canola and insect-resistant corn and cotton. New GMPs that produce vaccines, pharmaceutical or industrial proteins, and fortified food are approaching the market. The techniques employed to introduce foreign genes into plants allow a quite good degree of predictability of the results, and their genome is minimally modified. However, some aspects of GMPs have raised concern: (a) control of the insertion site of the introduced DNA sequences into the plant genome and of its mutagenic effect; (b) presence of selectable marker genes conferring resistance to an antibiotic or an herbicide, linked to the useful gene; (c) insertion of undesired bacterial plasmid sequences; and (d) gene flow from transgenic plants to non-transgenic crops or wild plants. In response to public concerns, genetic engineering techniques are continuously being improved. Techniques to direct foreign gene integration into chosen genomic sites, to avoid the use of selectable genes or to remove them from the cultivated plants, to reduce the transfer of undesired bacterial sequences, and make use of alternative, safer selectable genes, are all fields of active research. In our laboratory, some of these new techniques are applied to alfalfa, an important forage plant. These emerging methods for plant genetic engineering are briefly reviewed in this work

  19. [Intoxications with plants].

    Science.gov (United States)

    Kupper, Jacqueline; Reichert, Cornelia

    2009-05-01

    Ingestions of plants rarely lead to life-threatening intoxications. Highly toxic plants, which can cause death, are monkshood (Aconitum sp.), yew (Taxus sp.) and autumn crocus (Colchicum autumnale). Lethal ingestions of monkshood and yew are usually suicides, intoxications with autumn crocus are mostly accidental ingestions of the leaves mistaken for wild garlic (Allium ursinum). Severe intoxications can occur with plants of the nightshade family like deadly nightshade (Atropa belladonna), angel's trumpet (Datura suaveolens) or jimsonweed (Datura stramonium). These plants are ingested for their psychoactive effects. Ingestion of plant material by children most often only causes minor symptoms or no symptoms at all, as children usually do not eat great quantities of the plants. They are especially attracted by the colorful berries. There are plants with mostly cardiovascular effects like monkshood, yew and Digitalis sp. Some of the most dangerous plants belong to this group. Plants of the nightshade family cause an anticholinergic syndrome. With golden chain (Laburnum anagyroides), castor bean (Ricinus communis) and raw beans (Phaseolus vulgaris) we see severe gastrointestinal effects. Autumn crocus contains a cell toxin, colchicine, which leads to multiorgan failure. Different plants are irritative or even caustic to the skin. Treatment is usually symptomatic. Activated charcoal is administered within one hour after ingestion (1 g/kg). Endoscopic removal of plant material can be considered with ingestions of great quantities of highly toxic plants. Administration of repeated doses of charcoal (1-2 g/h every 2-4 hours) may be effective in case of oleander poisoning. There exist only two antidotes: Anti-digoxin Fab fragments can be used with cardenolide glycoside-containing plants (Digitalis sp., Oleander). Physostigmine is the antidote for severe anticholinergic symptoms of the CNS. Antibodies against colchicine, having been developed in France, are not available at

  20. Methodology for electrical studies in industrial networks including the study of electric arc; Metodologia para los estudios electricos en redes industriales incluyendo el estudio de arco electrico

    Energy Technology Data Exchange (ETDEWEB)

    Rasgado Casique, Jose Pepe; Silva Farias, Jose Luis [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)]. E-mail: jrasgado@iie.org.mx; jlsilva@iie.org.mx

    2010-11-15

    This article presents a methodology for conducting electrical studies in industrial networks. The methodology included the study of arc flash as a very important area of current basic electrical studies, such as power flow, short circuit and coordination. The aim of this study is to determine the Personal Protective Equipment (PPE) and flash protection boundary for personnel working with or near energized equipment, based on the IEEE Std 1584-2004 and NFPA-70E- 2004. Also included are criteria and recommendations to reduce incident energy level (cal/cm{sup 2}). At work we used a distribution network for industrial type test. The studies were carried out using a commercial program for the analysis of electrical networks. [Spanish] En este articulo se presenta una metodologia para llevar a cabo los estudios electricos en redes industriales. En la metodologia se incluye al estudio de arco electrico como un area muy importante de los estudios electricos basicos actuales, como: flujos de potencia, cortocircuito y coordinacion de protecciones. El objetivo de dicho estudio es determinar el Equipo de Proteccion Personal (EPP) apropiado y los limites de proteccion para el personal que opera con o cerca de equipo energizado, con base en las normas IEEE Std. 1584-2004 y la NFPA-70E-2004. Ademas, se incluyen criterios y recomendaciones para disminuir el nivel de energia incidente (cal/cm{sup 2}). En el trabajo se utilizo una red de distribucion tipo industrial de prueba. Los estudios se llevaron a cabo utilizando un programa comercial para el analisis de redes electricas.

  1. Nuclear power plants

    International Nuclear Information System (INIS)

    Margulova, T.Ch.

    1976-01-01

    The textbook focuses on the technology and the operating characteristics of nuclear power plants equiped with pressurized water or boiling water reactors, which are in operation all over the world at present. The following topics are dealt with in relation to the complete plant and to economics: distribution and consumption of electric and thermal energy, types and equipment of nuclear power plants, chemical processes and material balance, economical characteristics concerning heat and energy, regenerative preheating of feed water, degassing and condenser systems, water supply, evaporators, district heating systems, steam generating systems and turbines, coolant loops and pipes, plant siting, ventilation and decontamination systems, reactor operation and management, heat transfer including its calculation, design of reactor buildings, and nuclear power plants with gas or sodium cooled reactors. Numerous technical data of modern Soviet nuclear power plants are included. The book is of interest to graduate and post-graduate students in the field of nuclear engineering as well as to nuclear engineers

  2. Conditional sterility in plants

    Science.gov (United States)

    Meagher, Richard B.; McKinney, Elizabeth; Kim, Tehryung

    2010-02-23

    The present disclosure provides methods, recombinant DNA molecules, recombinant host cells containing the DNA molecules, and transgenic plant cells, plant tissue and plants which contain and express at least one antisense or interference RNA specific for a thiamine biosynthetic coding sequence or a thiamine binding protein or a thiamine-degrading protein, wherein the RNA or thiamine binding protein is expressed under the regulatory control of a transcription regulatory sequence which directs expression in male and/or female reproductive tissue. These transgenic plants are conditionally sterile; i.e., they are fertile only in the presence of exogenous thiamine. Such plants are especially appropriate for use in the seed industry or in the environment, for example, for use in revegetation of contaminated soils or phytoremediation, especially when those transgenic plants also contain and express one or more chimeric genes which confer resistance to contaminants.

  3. Plant synthetic biology.

    Science.gov (United States)

    Liu, Wusheng; Stewart, C Neal

    2015-05-01

    Plant synthetic biology is an emerging field that combines engineering principles with plant biology toward the design and production of new devices. This emerging field should play an important role in future agriculture for traditional crop improvement, but also in enabling novel bioproduction in plants. In this review we discuss the design cycles of synthetic biology as well as key engineering principles, genetic parts, and computational tools that can be utilized in plant synthetic biology. Some pioneering examples are offered as a demonstration of how synthetic biology can be used to modify plants for specific purposes. These include synthetic sensors, synthetic metabolic pathways, and synthetic genomes. We also speculate about the future of synthetic biology of plants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Annual Plant Reviews

    DEFF Research Database (Denmark)

    , three dimensional structures and functions of each protein in a biological system. In plant science, the number of proteome studies is rapidly expanding after the completion of the Arabidopsis thaliana genome sequence, and proteome analyses of other important or emerging model systems and crop plants...... are in progress or are being initiated. Proteome analysis in plants is subject to the same obstacles and limitations as in other organisms, but the nature of plant tissues, with their rigid cell walls and complex variety of secondary metabolites, means that extra challenges are involved that may not be faced when...... analysing other organisms. This volume aims to highlight the ways in which proteome analysis has been used to probe the complexities of plant biochemistry and physiology. It is aimed at researchers in plant biochemistry, genomics, transcriptomics and metabolomics who wish to gain an up-to-date insight...

  5. Towards plant wires

    OpenAIRE

    Adamatzky, Andrew

    2014-01-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self...

  6. Design of chemical plant

    International Nuclear Information System (INIS)

    Lee, Dong Il; Kim, Seung Jae; Yang, Jae Ho; Ryu, Hwa Won

    1993-01-01

    This book describes design of chemical plant, which includes chemical engineer and plan for chemical plant, development of chemical process, cost engineering pattern, design and process development, general plant construction plan, project engineering, foundation for economy on assets and depreciation, estimation for cost on capital investment and manufacturing cost, design with computers optimal design and method like fluid mechanics design chemical device and estimation for cost, such as dispatch of material and device writing on design report and appendixes.

  7. Late Palaeozoic plants.

    Science.gov (United States)

    Feng, Zhuo

    2017-09-11

    Land plants are one of the major constituents of terrestrial ecosystems on Earth, and play an irreplaceable role in human activities today. If we are to understand the extant plants, it is imperative that we have some understanding of the fossil plants from the deep geological past, particularly those that occurred during their early evolutionary history, in the late Palaeozoic. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Plant Habitat (PH)

    Science.gov (United States)

    Onate, Bryan

    2016-01-01

    The International Space Station (ISS) will soon have a platform for conducting fundamental research of Large Plants. Plant Habitat (PH) is designed to be a fully controllable environment for high-quality plant physiological research. PH will control light quality, level, and timing, temperature, CO2, relative humidity, and irrigation, while scrubbing ethylene. Additional capabilities include leaf temperature and root zone moisture and oxygen sensing. The light cap will have red (630 nm), blue (450 nm), green (525 nm), far red (730 nm) and broad spectrum white LEDs. There will be several internal cameras (visible and IR) to monitor and record plant growth and operations.

  9. Integrated Nuclear Recycle Plant

    International Nuclear Information System (INIS)

    Patodi, Anuj; Parashar, Abhishek; Samadhiya, Akshay K.; Ray, Saheli; Dey, Mitun; Singh, K.K.

    2017-01-01

    Nuclear Recycle Board (NRB), Tarapur proposes to set up an 'Integrated Nuclear Recycle Plant' at Tarapur. This will be located in the premises of BARC facilities. The project location is at coastal town of Tarapur, 130 Km north of Mumbai. Project area cover of INRP is around 80 hectares. The plant will be designed to process spent fuel received from Pressurized Heavy Water Reactors (PHWRs). This is the first large scale integrated plant of the country. INRP will process spent fuel obtained from indigenous nuclear power plants and perform left over nuclear waste disposal

  10. Towards plant wires.

    Science.gov (United States)

    Adamatzky, Andrew

    2014-08-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self-growing wetware circuits and devices, and integration of plant-based electronic components into future and emergent bio-hybrid systems. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. MBS Native Plant Communities

    Data.gov (United States)

    Minnesota Department of Natural Resources — This data layer contains results of the Minnesota County Biological Survey (MCBS). It includes polygons representing the highest quality native plant communities...

  12. The Kuroshio power plant

    CERN Document Server

    Chen, Falin

    2013-01-01

    By outlining a new design or the Kuroshio power plant, new approaches to turbine design, anchorage system planning, deep sea marine engineering and power plant operations and maintenance are explored and suggested. The impact on the local environment, particularly in the face of natural disasters, is also considered to provide a well rounded introduction to plan and build a 30MW pilot power plant. Following a literature review, the six chapters of this book propose a conceptual design by focusing on the plant's core technologies and establish the separate analysis logics for turbine design and

  13. Plant Transporter Identification

    DEFF Research Database (Denmark)

    Larsen, Bo

    Membrane transport proteins (transporters) play a critical role for numerous biological processes, by controlling the movements of ions and molecules in and out of cells. In plants, transporters thus function as gatekeepers between the plant and its surrounding environment and between organs......, tissues, cells and intracellular compartments. Since plants are highly compartmentalized organisms with complex transportation infrastructures, they consequently have many transporters. However, the vast majority of predicted transporters have not yet been experimentally verified to have transport...... activity. This project contains a review of the implemented methods, which have led to plant transporter identification, and present our progress on creating a high-throughput functional genomics transporter identification platform....

  14. Less power plants

    International Nuclear Information System (INIS)

    TASR

    2003-01-01

    In the Slovak Republic the number of company power plants decreased as against 2001 by two sources. In present time only 35 companies have their own power plants. The companies Slovnaft, Kappa Sturovo, Slovensky hodvab Senica, Matador Puchov, Maytex Liptovsky MikuIas, Kovohuty Krompachy, Chemko Strazske and some Slovak sugar factories belong to the largest company power plants in force of distributing companies. Installed output of present 35 company sources is 531 MW. The largest of separate power plants as Paroplynovy cyklus Bratislava (218 MW) and VD Zilina (72 MW) belong to independent sources. Total installed output of Slovak sources was 8306 MW in the end of last year

  15. Offshore atomic power plants

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Various merits of offshore atomic power plants are illustrated, and their systems are assessed. The planning of the offshore atomic power plants in USA is reviewed, and the construction costs of the offshore plant in Japan were estimated. Air pollution problem may be solved by the offshore atomic power plants remarkably. Deep water at low temperature may be advantageously used as cooling water for condensers. Marine resources may be bred by building artificial habitats and by providing spring-up equipments. In the case of floating plants, the plant design can be standardized so that the construction costs may be reduced. The offshore plants can be classified into three systems, namely artificial island system, floating system and sea bottom-based system. The island system may be realized with the present level of civil engineering, but requires the development of technology for the resistance of base against earthquake and its calculation means. The floating system may be constructed with conventional power plant engineering and shipbuilding engineering, but the aseismatic stability of breakwater may be a problem to be solved. Deep water floating system and deep water submerging system are conceivable, but its realization may be difficult. The sea bottom-based system with large caissons can be realized by the present civil engineering, but the construction of the caissons, stability against earthquake and resistance to waves may be problems to be solved. The technical prediction and assessment of new plant sites for nuclear power plants have been reported by Science and Technology Agency in 1974. The construction costs of an offshore plant has been estimated by the Ministry of International Trade and Industry to be yen71,026/kW as of 1985. (Iwakiri, K.)

  16. Selenium accumulation by plants

    Science.gov (United States)

    White, Philip J.

    2016-01-01

    Background Selenium (Se) is an essential mineral element for animals and humans, which they acquire largely from plants. The Se concentration in edible plants is determined by the Se phytoavailability in soils. Selenium is not an essential element for plants, but excessive Se can be toxic. Thus, soil Se phytoavailability determines the ecology of plants. Most plants cannot grow on seleniferous soils. Most plants that grow on seleniferous soils accumulate 100 mg Se kg–1 dry matter. These plants are considered to be Se accumulators. Some species can even accumulate Se concentrations of 1000–15 000 mg Se kg–1 dry matter and are called Se hyperaccumulators. Scope This article provides an overview of Se uptake, translocation and metabolism in plants and highlights the possible genetic basis of differences in these between and within plant species. The review focuses initially on adaptations allowing plants to tolerate large Se concentrations in their tissues and the evolutionary origin of species that hyperaccumulate Se. It then describes the variation in tissue Se concentrations between and within angiosperm species and identifies genes encoding enzymes limiting the rates of incorporation of Se into organic compounds and chromosomal loci that might enable the development of crops with greater Se concentrations in their edible portions. Finally, it discusses transgenic approaches enabling plants to tolerate greater Se concentrations in the rhizosphere and in their tissues. Conclusions The trait of Se hyperaccumulation has evolved several times in separate angiosperm clades. The ability to tolerate large tissue Se concentrations is primarily related to the ability to divert Se away from the accumulation of selenocysteine and selenomethionine, which might be incorporated into non-functional proteins, through the synthesis of less toxic Se metabilites. There is potential to breed or select crops with greater Se concentrations in their edible tissues, which

  17. Generating power stations and optimization energetic of processes; Centrales generadoras y optimacion energetica de procesos

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez Ramirez, Ranulfo; Fernandez Montiel, Manuel Francisco [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    1999-07-01

    Some recent experiences of the Management of Thermal Processes of the Instituto de Investigaciones Electricas (IIE) related to the works on generating power stations of electricity, plants of cogeneration and energy saving are presented. [Spanish] Se presentan algunas experiencias recientes de la Gerencia de Procesos Termicos del Instituto de Investigaciones Electricas (IIE) relacionadas con los trabajos sobre centrales generadoras de electricidad, plantas de cogeneracion y ahorro de energia.

  18. Generalized conventional and intelligent supervisory control system for combined cycle generation power plants; Sistema de control supervisorio generalizado convencional e inteligente para centrales de generacion de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Morales, Miguel Angel

    2004-12-15

    The Mexican Electricity Utility (Comision Federal de Electricidad - CFE) growing program in Power Generation for the 2004 - 2008 period is based on Combined Cycle Power Plants (CCPP). In accordance with [CFE, 2000], the expected power generation capacity developed during such period will rise by the amount of 12876 MW, 10655 MW belonging to CCPP (82.75 %). With such important program for the increasing of Power Generation in Mexico, researches have to receive new technologies for CCPP, some of them not completely tested and immature, with the compromise to make then more efficient and reliable. Under such idea and looking to increase the automation level for CCPP with better control algorithms, the Supervisory Generalized Control (SGC) for CCPP was developed in this thesis, based on PID strategies and intelligent (fuzzy) control strategies. With the SGC is possible to get the best performance for the whole CCPP through the automatic starting, synchronizing and loading of the generating units (two gas turbines and one steam turbine) with a minimum participation of operators. To get the increased efficiency, the SGC generates the reference paths for both gas turbines (GT) first, and the steam turbine (ST). The SGC accelerates each unit with a minimum effort and vibrations getting the synchronizing speed in a minimum time and wasted energy. Then the SGC synchronize each unit taking minimum load quickly and loading up to the highest electric power value. All these can be done in an automated operation. The SGC employs two critical-process variable- control strategies, based on blade path temperature average (BPT Average) for Gas Turbines (GT) and the throttle steam pressure for the Steam Turbine (ST). The control algorithms designed take both units, the GT and the ST, picking up load to the highest process value avoiding the alarms activation and shutdown. This is possible only with such an automated control strategy. Test performed showed that with the SGC

  19. Better Plants Program Overview

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-09-30

    The U.S. Department of Energy’s (DOE’s) Better Buildings, Better Plants Program is a voluntary partnership initiative to drive significant energy efficiency improvement across energy intensive companies and organizations. 157 leading manufacturers and public water and wastewater treatment utilities are partnering with DOE through Better Plants to improve energy efficiency, slash carbon emissions, and cut energy costs.

  20. Plant Glandular Trichomes

    Indian Academy of Sciences (India)

    landing on the plant. Glandular trichomes in catmint (Nepeta sp.) produce nepetalactone, closely related to the aphid sex pheromone, nepetalactol. Nepetalactone can be reduced to the corresponding nepetalactol. ... Plant glandular trichomes function either as repositories or releasing sites of various chemicals. Interest in ...

  1. Plants as green phones

    NARCIS (Netherlands)

    Soler, R.; Harvey, J.A.; Bezemer, T.M.; Stuefer, J.F.

    2008-01-01

    Plants can act as vertical communication channels or `green phones¿ linking soil-dwelling insects and insects in the aboveground ecosystem. When root-feeding insects attack a plant, the direct defense system of the shoot is activated, leading to an accumulation of phytotoxins in the leaves. The

  2. Solar thermal power plants

    International Nuclear Information System (INIS)

    Schnatbaum, L.

    2009-01-01

    The solar thermal power plant technology, the opportunities it presents and the developments in the market are outlined. The focus is on the technology of parabolic trough power plants, a proven technology for solar power generation on a large scale. In a parabolic trough power plant, trough-shaped mirrors concentrate the solar irradiation onto a pipe in the focal line of the collector. The thermal energy thus generated is used for electricity generation in a steam turbine. Parabolic trough plants can be combined with thermal storage and fossil or biomass fired heat exchangers to generate electricity even when the sun is not shining. Solar Millennium AG in Erlangen has developed the first power plant of this kind in Europe. After two years of construction the plant started operation in Southern Spain in 2008. This one and its sister projects are important steps leading the way for the whole market. The paper also covers the technological challenges, the key components used and the research and development activities concerning this technology. Solar thermal power plants are ideal for covering peak and medium loads in power grids. In hybrid operation they can also cover base-load. The Solar Chimney power plant, another striking technology for the conversion of solar into electric energy, is described briefly. The paper concludes with a look at the future - the import of solar energy from the deserts of North Africa to central Europe. (author)

  3. Redox signaling in plants.

    Science.gov (United States)

    Foyer, Christine H; Noctor, Graham

    2013-06-01

    Our aim is to deliver an authoritative and challenging perspective of current concepts in plant redox signaling, focusing particularly on the complex interface between the redox and hormone-signaling pathways that allow precise control of plant growth and defense in response to metabolic triggers and environmental constraints and cues. Plants produce significant amounts of singlet oxygen and other reactive oxygen species (ROS) as a result of photosynthetic electron transport and metabolism. Such pathways contribute to the compartment-specific redox-regulated signaling systems in plant cells that convey information to the nucleus to regulate gene expression. Like the chloroplasts and mitochondria, the apoplast-cell wall compartment makes a significant contribution to the redox signaling network, but unlike these organelles, the apoplast has a low antioxidant-buffering capacity. The respective roles of ROS, low-molecular antioxidants, redox-active proteins, and antioxidant enzymes are considered in relation to the functions of plant hormones such as salicylic acid, jasmonic acid, and auxin, in the composite control of plant growth and defense. Regulation of redox gradients between key compartments in plant cells such as those across the plasma membrane facilitates flexible and multiple faceted opportunities for redox signaling that spans the intracellular and extracellular environments. In conclusion, plants are recognized as masters of the art of redox regulation that use oxidants and antioxidants as flexible integrators of signals from metabolism and the environment.

  4. Cognition in plants

    NARCIS (Netherlands)

    Calvo, P.; Keijzer, F.A.

    2009-01-01

    To what extent can plants be considered cognitive from the perspective of embodied cognition? Cognition is interpreted very broadly within embodied cognition, and the current evidence for plant intelligence might find an important theoretical background here. However, embodied cognition does stress

  5. Invertebrates and Plants

    Science.gov (United States)

    Wendell R. Haag; Robert J. Distefano; Siobhan Fennessy; Brett D. Marshall

    2013-01-01

    Invertebrates and plants are among the most ubiquitous and abundant macroscopic organisms in aquatic ecosystems; they dominate most habitats in both diversity and biomass and play central roles in aquatic food webs. Plants regulate and create habitats for a wide array of organisms (Cooke et al. 2005). Snail grazing and bivalve filtering profoundly alter habitats and...

  6. Modulating lignin in plants

    Science.gov (United States)

    Apuya, Nestor; Bobzin, Steven Craig; Okamuro, Jack; Zhang, Ke

    2013-01-29

    Materials and methods for modulating (e.g., increasing or decreasing) lignin content in plants are disclosed. For example, nucleic acids encoding lignin-modulating polypeptides are disclosed as well as methods for using such nucleic acids to generate transgenic plants having a modulated lignin content.

  7. Recognizing Plant Defense Priming

    NARCIS (Netherlands)

    Martinez-Medina, Ainhoa; Flors, Victor; Heil, Martin; Mauch-Mani, Brigitte; Pieterse, Corné M J|info:eu-repo/dai/nl/113115113; Pozo, Maria J; Ton, Jurriaan; van Dam, Nicole M; Conrath, Uwe

    2016-01-01

    Defense priming conditions diverse plant species for the superinduction of defense, often resulting in enhanced pest and disease resistance and abiotic stress tolerance. Here, we propose a guideline that might assist the plant research community in a consistent assessment of defense priming in

  8. Exotic invasive plants

    Science.gov (United States)

    Carolyn Hull Sieg; Barbara G. Phillips; Laura P. Moser

    2003-01-01

    Ecosystems worldwide are threatened by nonnative plant invasions that can cause undesirable, irreversible changes. They can displace native plants and animals, out-cross with native flora, alter nutrient cycling and other ecosystem functions, and even change an ecosystem's flammability (Walker and Smith 1997). After habitat loss, the spread of exotic species is...

  9. Plant-Fungus Marriages

    Indian Academy of Sciences (India)

    Every plant requires mineral elements for growth. A mnemonic ... lar coils. More commonly, the hypha forms highly branched, .... stamps on the edible and poisonous mushrooms (Figure 2). One of the ... but these days dogs are used for truffle. 'hunting' . .... example is a non-chlorophyllous plant known as Indian pipe or.

  10. Dormancy in Plant Seeds

    NARCIS (Netherlands)

    Hilhorst, H.W.M.; Finch-Savage, W.E.; Buitink, J.; Bolingue, W.; Leubner-Metzger, G.

    2010-01-01

    Seed dormancy has been studied intensely over the past decades and, at present, knowledge of this plant trait is at the forefront of plant biology. The main model species is Arabidopsis thaliana, an annual weed, possessing nondeep physiological dormancy. This overview presents the state-of-the-art

  11. Slavery in plants

    NARCIS (Netherlands)

    Kabiri, S.; Rodenburg, J.; Ast, van A.; Bastiaans, L.

    2017-01-01

    The rain-fed lowland rice weed Rhamphicarpa fistulosa (Rice Vampireweed) is a facultative root parasitic plant. Growth and reproduction of R. fistulosa benefit considerably from parasitism, but how this affects the host plant is not well established. We determined accumulation and partitioning of

  12. Power plant chemical technology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    17 contributions covering topies of fossil fuel combustion, flue gas cleaning, power plant materials, corrosion, water/steam cycle chemistry, monitoring and control were presented at the annual meeting devoted to Power Plant Chemical Technology 1996 at Kolding (Denmark) 4-6 September 1996. (EG)

  13. Plant diagnosis device

    International Nuclear Information System (INIS)

    Tozuka, Shin-ichi.

    1996-01-01

    Standard data approximately defined are inputted as 1:1 functional data between at least two or more plant data and each of plant data are inputted. Diagnosis data corresponding to each of process data are formed based on the functional data. Limit value data to be a threshold value which determines whether the diagnosis data are in a predetermined state or not are formed. The diagnosis data and the limit value data are displayed in a recognizable state. If diagnosis data of a plurality of plants are displayed simultaneously, all of the plant data are substantially the same value with one standard datum if the plant is in a normal state. When abnormality should occur in the plant, the difference between the diagnosis data and the standard data is remarkable, and the difference between the diagnosis data of other normal plant data and the standard data are also made remarkably, accordingly, the display of a plurality of diagnosis data is scattered thereby capable of diagnosing the abnormality of the plant. (N.H.)

  14. Methylome evolution in plants

    NARCIS (Netherlands)

    Vidalis, Amaryllis; Živković, Daniel; Wardenaar, René; Roquis, David; Tellier, Aurélien; Johannes, Frank

    2016-01-01

    Despite major progress in dissecting the molecular pathways that control DNA methylation patterns in plants, little is known about the mechanisms that shape plant methylomes over evolutionary time. Drawing on recent intra- and interspecific epigenomic studies, we show that methylome evolution over

  15. Antimicrobial Peptides from Plants

    Directory of Open Access Journals (Sweden)

    James P. Tam

    2015-11-01

    Full Text Available Plant antimicrobial peptides (AMPs have evolved differently from AMPs from other life forms. They are generally rich in cysteine residues which form multiple disulfides. In turn, the disulfides cross-braced plant AMPs as cystine-rich peptides to confer them with extraordinary high chemical, thermal and proteolytic stability. The cystine-rich or commonly known as cysteine-rich peptides (CRPs of plant AMPs are classified into families based on their sequence similarity, cysteine motifs that determine their distinctive disulfide bond patterns and tertiary structure fold. Cystine-rich plant AMP families include thionins, defensins, hevein-like peptides, knottin-type peptides (linear and cyclic, lipid transfer proteins, α-hairpinin and snakins family. In addition, there are AMPs which are rich in other amino acids. The ability of plant AMPs to organize into specific families with conserved structural folds that enable sequence variation of non-Cys residues encased in the same scaffold within a particular family to play multiple functions. Furthermore, the ability of plant AMPs to tolerate hypervariable sequences using a conserved scaffold provides diversity to recognize different targets by varying the sequence of the non-cysteine residues. These properties bode well for developing plant AMPs as potential therapeutics and for protection of crops through transgenic methods. This review provides an overview of the major families of plant AMPs, including their structures, functions, and putative mechanisms.

  16. Nuclear Power Plants. Revised.

    Science.gov (United States)

    Lyerly, Ray L.; Mitchell, Walter, III

    This publication is one of a series of information booklets for the general public published by the United States Atomic Energy Commission. Among the topics discussed are: Why Use Nuclear Power?; From Atoms to Electricity; Reactor Types; Typical Plant Design Features; The Cost of Nuclear Power; Plants in the United States; Developments in Foreign…

  17. NUCLEAR POWER PLANT

    Science.gov (United States)

    Carter, J.C.; Armstrong, R.H.; Janicke, M.J.

    1963-05-14

    A nuclear power plant for use in an airless environment or other environment in which cooling is difficult is described. The power plant includes a boiling mercury reactor, a mercury--vapor turbine in direct cycle therewith, and a radiator for condensing mercury vapor. (AEC)

  18. Caladium plant poisoning

    Science.gov (United States)

    ... enough to prevent normal speaking and swallowing. Home Care If the plant was eaten, wipe out the mouth with a ... to Expect at the Emergency Room Take the plant with you to the hospital, if possible. The health care provider will measure and monitor the person's vital ...

  19. Gold in plants

    International Nuclear Information System (INIS)

    Girling, C.A.; Peterson, P.J.

    1980-01-01

    Many plants have the ability to take up gold from the soil and to accumulate it in their tisssue. Advances have been made in understanding these processes to the point where their exploitation in the field of prospecting for gold appears practically feasible. Neutron activation analysis is used for the determination of the small quantities of gold in plants

  20. Recognizing plant defense priming

    NARCIS (Netherlands)

    Martinez-Medina, A.; Flors, V.; Heil, M.; Mauch-Mani, B.; Pieterse, C.M.J.; Pozo, M.J.; Ton, J.; Van Dam, N.M.; Conrath, U.

    2016-01-01

    Defense priming conditions diverse plant species for the superinduction of defense, often resulting in enhanced pest and disease resistance and abiotic stress tolerance. Here, we propose a guideline that might assist the plant research community in a consistent assessment of defense priming in

  1. Carotenoid metabolism in plants

    Science.gov (United States)

    Carotenoids are mostly C40 terpenoids, a class of hydrocarbons that participate in various biological processes in plants, such as photosynthesis, photomorphogenesis, photoprotection, and development. Carotenoids also serve as precursors for two plant hormones and a diverse set of apocarotenoids. Th...

  2. [Neotropical plant morphology].

    Science.gov (United States)

    Pérez-García, Blanca; Mendoza, Aniceto

    2002-01-01

    An analysis on plant morphology and the sources that are important to the morphologic interpretations is done. An additional analysis is presented on all published papers in this subject by the Revista de Biología Tropical since its foundation, as well as its contribution to the plant morphology development in the neotropics.

  3. Chemical processes of coal for use in power plants. Part 1: Approximate analysis and associated indexes of pulverized coal; Procesos quimicos del carbon para su uso en centrales termoelectricas. Parte 1: Analisis aproximado e indices asociados del carbon pulverizado

    Energy Technology Data Exchange (ETDEWEB)

    Altamirano-Bedolla, J. A.; Manzanares-Papayanopoulos, E.; Herrera-Velarde, J. R. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)]. E-mail: emp@iie.org.mx

    2010-11-15

    The usage of hydrocarbons, such as natural gas, oil products and coal, will be the main source of energy to the mankind for next generations. Therefore, the actual research and technological developments point out to employ with high efficiency those fuels. The main interests are to release most of the energy as possible and to guide the combustion reactions. It is well known that during the combustion process of coal, the chemical energy is converted to thermal energy, which it allows the steam production, and therefore to produce energy through an electric generator. The main interest of the work presented here is to study the behavior of the coal combustion processes in function of the approximate analysis and some associate indices of that analysis, to point out the optimization of the coal usage as main fuel in electrical power generation plants. [Spanish] El uso de hidrocarburos como son el gas natural, los derivados del petroleo y el carbon mineral, continuara siendo en las proximas decadas la principal fuente de energia de la humanidad. Por consiguiente, la investigacion cientifica y los desarrollos tecnologicos actualmente se enfocan en emplear de manera mas eficiente dichos combustibles, satisfaciendo entre otros factores, dos intereses principales: liberar la mayor cantidad de energia, reduciendo al minimo el material combustible no quemado, y direccionar las reacciones del proceso de combustion para minimizar la cantidad de productos no deseados resultantes de la reaccion. A traves de los procesos quimicos de combustion del carbon, se transforma la energia quimica a energia termica, lo que permite la produccion de vapor para a su vez impulsar una turbina la cual esta acoplada a un generador electrico. El objetivo del presente trabajo es el estudio del comportamiento de los procesos quimicos que se llevan a cabo durante las reacciones de combus-tion del carbon en funcion del analisis aproximado y de los indices asociados resultantes de dicho analisis; lo

  4. Automatic micropropagation of plants

    Science.gov (United States)

    Otte, Clemens; Schwanke, Joerg; Jensch, Peter F.

    1996-12-01

    Micropropagation is a sophisticated technique for the rapid multiplication of plants. It has a great commercial potential due to the speed of propagation, the high plant quality, and the ability to produce disease-free plants. However, micropropagation is usually done by hand which makes the process cost-intensive and tedious for the workers especially because it requires a sterile work-place. Therefore, we have developed a prototype automation system for the micropropagation of a grass species (miscanthus sinensis gigantheus). The objective of this paper is to describe the robotic system in an overview and to discuss the vision system more closely including the implemented morphological operations recognizing the cutting and gripping points of miscanthus plants. Fuzzy controllers are used to adapt the parameters of image operations on-line to each individual plant. Finally, we discuss our experiences with the developed prototype an give a preview of a possible real production line system.

  5. Plants and fluorine

    Energy Technology Data Exchange (ETDEWEB)

    Garber, K

    1962-01-01

    A report is given about the contents of fluorine in soil and different plants. It is stated that spinach and several spice herbages are rich in fluorine (0.98 - 21.8 ppm) while in other plants are not more than 5 ppm maximum. An exception is found in Thea sinensis with 178 ppm and more. Tea is, therefore, a source of fluorine for contamination of the human body. An increase of the fluorine contents of plants by manuring with F-salts or mineral manure is possible but of long duration. Damage to plants by uptake of fluorine from soil as well as in a gaseous condition from the atmosphere are described. The rate of damage is related to the type of soil in which the plant is grown.

  6. Poultry Plant Noise Control

    Science.gov (United States)

    1982-01-01

    A demonstration conducted last winter at the Tip Top Poultry Plant intended to show poultry plant managers from all over the U.S. potential solutions to the problem of plant noise. Plastic covers used over sound absorbing materials need to meet cleanability requirements, high- pressure water cleaning and other harsh maintenance procedures peculiar to the poultry processing industry. For the demonstration, Fiber Flex, Inc. manufactured and donated 750 noise panels; Owens-Corning Fiberglas Corporation donated the fiberglas cores; and the cover material was purchased from Howe and Bainbridge. The Engineering Experiment Station (EES) conducted before and after noise surveys and is evaluating the effect of noise reduction on turnover and productivity in the demonstration plant. EES plans to conduct a noise abatement workshop and update a handbook to help poultry processors with noise problems. EES study and demonstration may be applicable to other food processing plants where similar sanitary constraints exist.

  7. Protein carbonylation in plants

    DEFF Research Database (Denmark)

    Møller, Ian Max; Havelund, Jesper; Rogowska-Wrzesinska, Adelina

    2017-01-01

    This chapter provides an overview of the current knowledge on protein carbonylation in plants and its role in plant physiology. It starts with a brief outline of the turnover and production sites of reactive oxygen species (ROS) in plants and the causes of protein carbonylation. This is followed...... by a description of the methods used to study protein carbonylation in plants, which is also very brief as the methods are similar to those used in studies on animals. The chapter also focuses on protein carbonylation in plants in general and in mitochondria and in seeds in particular, as case stories where...... specific carbonylated proteins have been identified. Protein carbonylation appears to accumulate at all stages of seed development and germination investigated to date. In some cases, such as seed aging, it is probably simply an accumulation of oxidative damage. However, in other cases protein...

  8. Plant control device

    International Nuclear Information System (INIS)

    Sato, Masuo; Ono, Makoto.

    1995-01-01

    A plant control device comprises an intellectual instrumentation group for measuring a predetermined process amount, an intellectual equipment group operating in accordance with a self-countermeasure, a system information space for outputting system information, a system level monitoring and diagnosing information generalization section for outputting system information, a system level maintenance information generalization section for outputting information concerning maintenance, a plant level information space and a plant level information generalization section. Each of them determines a state of the plant autonomously, and when abnormality is detected, each of the intellectual instrumentation, equipments and systems exchange information with each other, to conduct required operations including operations of intellectual robots, as required. Appropriate countermeasures for gauges, equipments and systems can be conducted autonomously at a place where operators can not access to improve reliability of complicate operations in the working site, as well as improve plant safety and reliability. (N.H.)

  9. Plant abnormality inspection device

    International Nuclear Information System (INIS)

    Takenaka, Toshio.

    1990-01-01

    The present invention concerns a plant abnormality inspection device for conducting remote or automatic patrolling inspection in a plant and, more particularly, relates to such a device as capable of detecting abnormal odors. That is, the device comprises a moving device for moving to a predetermined position in the plant, a plurality of gas sensors for different kind of gases to be inspected mounted thereon, a comparator for comparing the concentration of a gas detected by the gas sensor with the normal gas concentration at the predetermined position and a judging means for judging the absence or presence of abnormality depending on the combination of the result of the comparison and deliverying a signal if the state is abnormal. As a result, a slight amount of gas responsible to odors released upon abnormality of the plant can be detected by a plurality of gas sensors for different kinds gases to rapidly and easily find abnormal portions in the plant. (I.S.)

  10. Nuclear power plant siting

    International Nuclear Information System (INIS)

    Sulkiewicz, M.; Navratil, J.

    The construction of a nuclear power plant is conditioned on territorial requirements and is accompanied by the disturbance of the environment, land occupation, population migration, the emission of radioactive wastes, thermal pollution, etc. On the other hand, a nuclear power plant makes possible the introduction of district heating and increases the economic and civilization activity of the population. Due to the construction of a nuclear power plant the set limits of negative impacts must not be exceeded. The locality should be selected such as to reduce the unfavourable effects of the plant and to fully use its benefits. The decision on the siting of the nuclear power plant is preceded by the processing of a number of surveys and a wide range of documentation to which the given criteria are strictly applied. (B.H.)

  11. Manganese deficiency in plants

    DEFF Research Database (Denmark)

    Schmidt, Sidsel Birkelund; Jensen, Poul Erik; Husted, Søren

    2016-01-01

    Manganese (Mn) is an essential plant micronutrient with an indispensable function as a catalyst in the oxygen-evolving complex (OEC) of photosystem II (PSII). Even so, Mn deficiency frequently occurs without visual leaf symptoms, thereby masking the distribution and dimension of the problem...... restricting crop productivity in many places of the world. Hence, timely alleviation of latent Mn deficiency is a challenge in promoting plant growth and quality. We describe here the key mechanisms of Mn deficiency in plants by focusing on the impact of Mn on PSII stability and functionality. We also address...... the mechanisms underlying the differential tolerance towards Mn deficiency observed among plant genotypes, which enable Mn-efficient plants to grow on marginal land with poor Mn availability....

  12. Communal biomass conversion plants

    International Nuclear Information System (INIS)

    Holm-Nielsen, J.B.; Huntingford, S.; Halberg, N.

    1993-03-01

    The aim was to show the agricultural advantages of farmers being in connection with Communal Biogas Plant. Whether a more environmentally protectire distribution of plant nutrients from animal manure takes place through a biogas plants distribution system, whether the nitrogen in the digested slurry is better utilized and whether the connection results in slurry transportation-time reduction, are discussed. The average amount of nitrogen from animal manure used per hectare was reduced. The area of manure distribution was larger. The nitrogen efficiency was increased when using digested slurry and purchase of N mineral fertilizer decreased, resulting in considerable reduction in nitrogen leaching. The amount of slurry delivered to the local storage tanks was approximately 45 per cent of the total amount treated on the biogas plant. Conditions of manure transport improved greatly as this was now the responsibility of the communal biomass conversion plant administrators. (AB) (24 refs.)

  13. Encapsulation plant at Forsmark

    International Nuclear Information System (INIS)

    Nystroem, Anders

    2007-08-01

    SKB has already carried out a preliminary study of an encapsulation plant detached from Clab (Central interim storage for spent fuels). This stand-alone encapsulation plant was named FRINK and its assumed siting was the above-ground portion of the final repository, irrespective of the repository's location. The report previously presented was produced in cooperation with BNFL Engineering Ltd in Manchester and the fuel reception technical solution was examined by Gesellschaft fuer Nuklear-Service mbH (GNS) in Hannover and by Societe Generale pour les Techniques Nouvelles (SGN) in Paris. This report is an update of the earlier preliminary study report and is based on the assumption that the encapsulation plant and also the final repository will be sited in the Forsmark area. SKB's main alternative for siting the encapsulation plant is next to Clab. Planning of this facility is ongoing and technical solutions from the planning work have been incorporated in this report. An encapsulation plant placed in proximity to any final repository in Forsmark forms part of the alternative presentation in the application for permission to construct and operate an installation at Clab. The main technical difference between the planned encapsulation plant at Clab and an encapsulation plant at a final repository at Forsmark is how the fuel is managed and prepared before actual encapsulation. Fuel reception at the encapsulation plant in Forsmark would be dry, i.e. there would be no water-filled pools at the facility. Clab is used for verificatory fuel measurements, sorting and drying of the fuel before transport to Forsmark. This means that Clab will require a measure of rebuilding and supplementary equipment. In purely technical terms, the prospects for building an encapsulation plant sited at Forsmark are good. A description of the advantages and drawbacks of siting the encapsulation plant at Clab as opposed to any final repository at Forsmark is presented in a separate report

  14. Encapsulation plant at Forsmark

    Energy Technology Data Exchange (ETDEWEB)

    Nystroem, Anders

    2007-08-15

    SKB has already carried out a preliminary study of an encapsulation plant detached from Clab (Central interim storage for spent fuels). This stand-alone encapsulation plant was named FRINK and its assumed siting was the above-ground portion of the final repository, irrespective of the repository's location. The report previously presented was produced in cooperation with BNFL Engineering Ltd in Manchester and the fuel reception technical solution was examined by Gesellschaft fuer Nuklear-Service mbH (GNS) in Hannover and by Societe Generale pour les Techniques Nouvelles (SGN) in Paris. This report is an update of the earlier preliminary study report and is based on the assumption that the encapsulation plant and also the final repository will be sited in the Forsmark area. SKB's main alternative for siting the encapsulation plant is next to Clab. Planning of this facility is ongoing and technical solutions from the planning work have been incorporated in this report. An encapsulation plant placed in proximity to any final repository in Forsmark forms part of the alternative presentation in the application for permission to construct and operate an installation at Clab. The main technical difference between the planned encapsulation plant at Clab and an encapsulation plant at a final repository at Forsmark is how the fuel is managed and prepared before actual encapsulation. Fuel reception at the encapsulation plant in Forsmark would be dry, i.e. there would be no water-filled pools at the facility. Clab is used for verificatory fuel measurements, sorting and drying of the fuel before transport to Forsmark. This means that Clab will require a measure of rebuilding and supplementary equipment. In purely technical terms, the prospects for building an encapsulation plant sited at Forsmark are good. A description of the advantages and drawbacks of siting the encapsulation plant at Clab as opposed to any final repository at Forsmark is presented in a separate

  15. Biofuelled heating plants

    International Nuclear Information System (INIS)

    Gulliksson, Hans; Wennerstaal, L.; Zethraeus, B.; Johansson, Bert-Aake

    2001-11-01

    The purpose of this report is to serve as a basis to enable establishment and operation of small and medium-sized bio-fuel plants, district heating plants and local district heating plants. Furthermore, the purpose of this report is to serve as a guideline and basis when realizing projects, from the first concept to established plant. Taking into account all the phases, from selection of heating system, fuel type, selection of technical solutions, authorization request or application to operate a plant, planning, construction and buying, inspection, performance test, take-over and control system of the plant. Another purpose of the report is to make sure that best available technology is used and to contribute to continuous development of the technology. The report deals mainly with bio-fuelled plants in the effect range 0.3 to10 MW. The term 'plant' refers to combined power and heating plants as well as 'simpler' district heating plants. The last-mentioned is also often referred to as 'local heating plant'. In this context, the term bio fuel refers to a wide range of fuel types. The term bio fuel includes processed fractions like powders, pellets, and briquettes along with unprocessed fractions, such as by-products from the forest industry; chips and bark. Bio fuels also include straw, energy crops and cereal waste products, but these have not been expressly studied in this report. The report is structured with appendixes regarding the various phases of the projects, with the purpose of serving as a helping handbook, or manual for new establishment, helping out with technical and administrative advice and environmental requirements. Plants of this size are already expanding considerably, and the need for guiding principles for design/technology and environmental requirements is great. These guiding principles should comply with the environmental legislation requirements, and must contain advice and recommendations for bio fuel plants in this effect range, also in

  16. Populations in clonal plants

    Directory of Open Access Journals (Sweden)

    Jussi Tammisola

    1986-12-01

    Full Text Available Population phenomena in higher plants are reviewed critically, particularly in relation to clonality. An array of concepts used in the field are discussed. In contrast to animals, higher plants are modular in structure. Plant populations show hierarchy at two levels: ramets and genets. In addition, their demography is far more complicated, since even the direction of development of a ramet may change by rejuvenation. Therefore, formulae concerning animal populations often require modification for plants. Furthermore, at the zygotic stage, higher plants are generally less mobile than animals. Accordingly, their population processes tend to be more local. Most populations of plants have a genetic structure: alleles and genotypes are spatially aggregated. Due to the short-ranged foraging behaviour of pollinators, genetically non-random pollination prevails. A generalized formula for parent-offspring dispersal variance is derived. It is used to analyze the effect of clonality on genetic patchiness in populations. In self-compatible species, an increase in clonality will tend to increase the degree of patchiness, while in self-incompatible species a decrease may result. Examples of population structure studies in different species are presented. A considerable degree of genetic variation appears to be found also in the populations of species with a strong allocation of resources to clonal growth or apomictic seed production. Some consequences of clonality are considered from the point of view of genetic conservation and plant breeding.

  17. Experimental mutagenesis in plants

    International Nuclear Information System (INIS)

    Conger, B.V.

    1979-01-01

    Considerable progress has been made in directed or controlled mutagenesis with bacterial systems, the genetic resolving power of which is much greater than that of higher plants. The mutagen specificity in higher plants has been of great interest, and numerous results and observations have been reported. The advances in the culture of plant cells and tissues have created much interest concerning the possibility of inducing and recovering mutants at the cellular level. There are great problems including the failure to regenerate plants from cells in all but a few species. The genetic and cytogenetic instability in the culture of plant tissues is well known, and the most common nuclear change is polyploidy including aneuploidy. The degree of polyploidy increases with calluses or culture age. In rice, the frequency of aneuploidy is greater in the calluses derived from roots than those derived from stem internodes. Polyploid and/or self-incompatible plant species are not as amenable to conventional mutation breeding techniques as diploid, self-fertilizing species. Inducing mutations in somatic tissues creates the problem of chimeras. However, the new cultivars of highly heterozygous, outcrossing, self-incompatible species are produced by combining several different clones. The performance of the progeny of at least 4 generations removed from the polycross of the parent clones is the important factor, and a high amount of heterozygocity is tolerated within cultivars and even on the same plants. (Yamashita, S.)

  18. Plant state display device

    International Nuclear Information System (INIS)

    Kadota, Kazuo; Ito, Toshiichiro.

    1994-01-01

    The device of the present invention conducts information processing suitable for a man to solve a problem in a plant such as a nuclear power plant incorporating a great amount of information, where safety is required and provides information to an operator. Namely, theories and rules with respect to the flow and balanced state of materials and energy upon plant start-up, and a vapor cycle of operation fluids are symbolized and displayed on the display screen of the device. Then, the display of the plant information suitable to the information processing for a man to dissolve problems is provided. Accordingly, a mechanism for analyzing a purpose of the plant is made more definite, thereby enabling to prevent an erroneous judgement of an operator and occurrence of plant troubles. In addition, a simular effect can also be expected when the theories and rules with respect to the flow and the balanced state of materials and energy and thermohydrodynamic behavior of the operation fluids in a state of after-heat removing operation during shutdown of the plant are symbolized and displayed. (I.S.)

  19. Physiology of woody plants

    CERN Document Server

    Hazewinkel, Michiel; Pallardy, Stephen G

    1996-01-01

    This completely revised classic volume is an up-to-date synthesis of the intensive research devoted to woody plants. Intended primarily as a text for students and a reference for researchers, this interdisciplinary book should be useful to a broad range of scientists from agroforesters, agronomists, and arborists to plant pathologists, ecophysiologists, and soil scientists. Anyone interested in plant physiology will find this text invaluable. Key Features * Includes supplementary chapter summaries and lists of general references * Provides a solid foundation of reference information * Thoroughly updated classic text/reference.

  20. Interelement correlations in plants

    International Nuclear Information System (INIS)

    Markert, B.

    1987-01-01

    The concentration of 25 elements in 4 plant species (Citrus aurantia, Brassica oleracea, Lycopersicon esculentum and Pinus strobus) were linearly correlated. For some element pairs (Ce-Fe, Ce-Ni, Ce-Sb, Ce-Sc, Ce-Zn, Fe-Sb, Fe-Sc, Fe-U, Fe-Zn, K-Cd, La-U, Ni-Sb, Sc-U and Sc-Zn) a high positive correlation coefficient (r = +1) was found. The element pairs Ca-Mg, Hg-U, Ni-Sr and Sr-Zn show a significant negative correlation (r = -1). Plants seem to process some constant interelement relations, independent of plant species. (orig.)

  1. Radiation hormesis in plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Sung; Song, Hi Sup; Lee, Young Keun; Lee, Byung Hun; Shin, In Chul; Lim, Young Taek

    2000-04-01

    This research was performed to investigate the effects of low dose {gamma}-ray radiation on the seed germination and the following physiological responses in vegetable crops. Special attention was focused on whether the resistance of vegetables against the unfavorable conditions of environment such as subsequent high doses of radiation or Phytophthora blight of pepper could be enhanced as an aspect of radiation hormesis. Analysis and characterization of antioxidant enzyme from plant culture cells and radiation tolerant of transformed plants from antioxidant (POD) were accomplished in the plant irradiated with different dose of {gamma}-ray. (author)

  2. Selenium accumulation by plants.

    Science.gov (United States)

    White, Philip J

    2016-02-01

    Selenium (Se) is an essential mineral element for animals and humans, which they acquire largely from plants. The Se concentration in edible plants is determined by the Se phytoavailability in soils. Selenium is not an essential element for plants, but excessive Se can be toxic. Thus, soil Se phytoavailability determines the ecology of plants. Most plants cannot grow on seleniferous soils. Most plants that grow on seleniferous soils accumulate plant species have evolved tolerance to Se, and commonly accumulate tissue Se concentrations >100 mg Se kg(-1) dry matter. These plants are considered to be Se accumulators. Some species can even accumulate Se concentrations of 1000-15 000 mg Se kg(-1 )dry matter and are called Se hyperaccumulators. This article provides an overview of Se uptake, translocation and metabolism in plants and highlights the possible genetic basis of differences in these between and within plant species. The review focuses initially on adaptations allowing plants to tolerate large Se concentrations in their tissues and the evolutionary origin of species that hyperaccumulate Se. It then describes the variation in tissue Se concentrations between and within angiosperm species and identifies genes encoding enzymes limiting the rates of incorporation of Se into organic compounds and chromosomal loci that might enable the development of crops with greater Se concentrations in their edible portions. Finally, it discusses transgenic approaches enabling plants to tolerate greater Se concentrations in the rhizosphere and in their tissues. The trait of Se hyperaccumulation has evolved several times in separate angiosperm clades. The ability to tolerate large tissue Se concentrations is primarily related to the ability to divert Se away from the accumulation of selenocysteine and selenomethionine, which might be incorporated into non-functional proteins, through the synthesis of less toxic Se metabilites. There is potential to breed or select crops

  3. Radiation hormesis in plant

    International Nuclear Information System (INIS)

    Kim, Jae Sung; Song, Hi Sup; Lee, Young Keun; Lee, Byung Hun; Shin, In Chul; Lim, Young Taek

    2000-04-01

    This research was performed to investigate the effects of low dose γ-ray radiation on the seed germination and the following physiological responses in vegetable crops. Special attention was focused on whether the resistance of vegetables against the unfavorable conditions of environment such as subsequent high doses of radiation or Phytophthora blight of pepper could be enhanced as an aspect of radiation hormesis. Analysis and characterization of antioxidant enzyme from plant culture cells and radiation tolerant of transformed plants from antioxidant (POD) were accomplished in the plant irradiated with different dose of γ-ray. (author)

  4. Nuclear power plants maintenance

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Nuclear power plants maintenance now appears as an important factor contributing to the competitivity of nuclea energy. The articles published in this issue describe the way maintenance has been organized in France and how it led to an actual industrial activity developing and providing products and services. An information note about Georges Besse uranium enrichment plant (Eurodif) recalls that maintenance has become a main data not only for power plants but for all nuclear industry installations. (The second part of this dossier will be published in the next issue: vol. 1 January-February 1989) [fr

  5. Optofluidics of plants

    Directory of Open Access Journals (Sweden)

    Demetri Psaltis

    2016-05-01

    Full Text Available Optofluidics is a tool for synthesizing optical systems, making use of the interaction of light with fluids. In this paper we explore optofluidic mechanisms that have evolved in plants where sunlight and fluidic control combine to define most of the functionality of the plan. We hope that the presentation of how plants function, from an optofluidics point of view, will open a window for the optics community to the vast literature of plant physiology and provide inspiration for new ideas for the design of bio-mimetic optofluidic devices.

  6. Competitive breeder power plants

    International Nuclear Information System (INIS)

    Winkleblack, R.K.

    1984-01-01

    To utilize the fissile material that is accumulating in the utilities' spent fuel pools, breeder plants must be less expensive than current LWR costs (or utilities will not buy nuclear plants in the near future) and also be highly reliable. The fundamental differences between LWRs and LMFBRs are discussed and recommendations are made for making the most of these differences to design a superior breeder plant that can sell in the future, opening the way to U.S. utilities becoming self-sufficient for fuel supply for centuries

  7. Radiation hormesis in plant

    International Nuclear Information System (INIS)

    Kim, Jae Sung; Song, Hi Sup; Lee, Young Keun; Cun, Ki Jung; Shin, In Chul; Lim, Young Taek

    1999-04-01

    This research was performed to investigate the effects of low dose γ-ray radiation on the seed germination and the following physiological responses in vegetable crops. Special attention was focused on whether the resistance of vegetables against the unfavorable conditions of environment such as acid rain or soil types could be enhanced as an aspect of radiation hormesis. Analysis and characterization of antioxidant enzyme from plant culture cells and radiation tolerant of transformed plants from antioxidant enzyme (POD) were accomplished in the plant irradiated with difference dosage of γ-ray

  8. Coal gasification plant

    Energy Technology Data Exchange (ETDEWEB)

    1977-09-29

    The proposal concerns a stage in the process of cooling the synthetic gas produced in a coal gasification plant at temperatures above 900/sup 0/C. The purpose is to keep the convection heating surface of the subsequent waste heat plant free of dirt. According to the invention, the waste heat plant has a radiation area connected before it, on the heating surfaces of which the slack carried over solidifies. This radiation area has a hydraulic and thermal cleaning system, which can be raised or lowered in a water bath. The subclaims concern all the constructional characteristics of this cleaning system, which causes the solidified slack to crack.

  9. TOR signalling in plants.

    Science.gov (United States)

    Rexin, Daniel; Meyer, Christian; Robaglia, Christophe; Veit, Bruce

    2015-08-15

    Although the eukaryotic TOR (target of rapamycin) kinase signalling pathway has emerged as a key player for integrating nutrient-, energy- and stress-related cues with growth and metabolic outputs, relatively little is known of how this ancient regulatory mechanism has been adapted in higher plants. Drawing comparisons with the substantial knowledge base around TOR kinase signalling in fungal and animal systems, functional aspects of this pathway in plants are reviewed. Both conserved and divergent elements are discussed in relation to unique aspects associated with an autotrophic mode of nutrition and adaptive strategies for multicellular development exhibited by plants. © 2015 Authors; published by Portland Press Limited.

  10. Radiation hormesis in plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Sung; Song, Hi Sup; Lee, Young Keun; Cun, Ki Jung; Shin, In Chul; Lim, Young Taek

    1999-04-01

    This research was performed to investigate the effects of low dose {gamma}-ray radiation on the seed germination and the following physiological responses in vegetable crops. Special attention was focused on whether the resistance of vegetables against the unfavorable conditions of environment such as acid rain or soil types could be enhanced as an aspect of radiation hormesis. Analysis and characterization of antioxidant enzyme from plant culture cells and radiation tolerant of transformed plants from antioxidant enzyme (POD) were accomplished in the plant irradiated with difference dosage of {gamma}-ray.

  11. Nuclear power plant outages

    International Nuclear Information System (INIS)

    1998-01-01

    The Finnish Radiation and Nuclear Safety Authority (STUK) controls nuclear power plant safety in Finland. In addition to controlling the design, construction and operation of nuclear power plants, STUK also controls refuelling and repair outages at the plants. According to section 9 of the Nuclear Energy Act (990/87), it shall be the licence-holder's obligation to ensure the safety of the use of nuclear energy. Requirements applicable to the licence-holder as regards the assurance of outage safety are presented in this guide. STUK's regulatory control activities pertaining to outages are also described

  12. FRIB Cryogenic Plant Status

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, Kelly D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Ganni, Venkatarao [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Knudsen, Peter N. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Casagranda, Fabio [Michigan State Univ., East Lansing, MI (United States)

    2015-12-01

    After practical changes were approved to the initial conceptual design of the cryogenic system for MSU FRIB and an agreement was made with JLab in 2012 to lead the design effort of the cryogenic plant, many activities are in place leading toward a cool-down of the linacs prior to 2018. This is mostly due to using similar equipment used at CHLII for the 12 GeV upgrade at JLab and an aggressive schedule maintained by the MSU Conventional Facilities department. Reported here is an updated status of the cryogenic plant, including the equipment procurement status, plant layout, facility equipment and project schedule.

  13. Plant-soil feedbacks: role of plant functional group and plant traits

    NARCIS (Netherlands)

    Cortois, R.; Schröder-Georgi, T.; Weigelt, A.; van der Putten, W.H.; De Deyn, G.B.

    2016-01-01

    Plant-soil feedback (PSF), plant trait and functional group concepts advanced our understanding of plant community dynamics, but how they are interlinked is poorly known. To test how plant functional groups (FGs: graminoids, small herbs, tall herbs, legumes) and plant traits relate to PSF, we grew

  14. Plant Growth Promoting Rhizobacteria

    Indian Academy of Sciences (India)

    IAS Admin

    known to improve plant growth in many ways when compared to ... roles in agricultural productivity. ... Sustainable agriculture: Sustainable agriculture involves the successful management of agricultural re- ... For the first time Kloepper et al.

  15. KWU Nuclear Plant Analyzer

    International Nuclear Information System (INIS)

    Bennewitz, F.; Hummel, R.; Oelmann, K.

    1986-01-01

    The KWU Nuclear Plant Analyzer is a real time engineering simulator based on the KWU computer programs used in plant transient analysis and licensing. The primary goal is to promote the understanding of the technical and physical processes of a nuclear power plant at an on-site training facility. Thus the KWU Nuclear Plant Analyzer is available with comparable low costs right at the time when technical questions or training needs arise. This has been achieved by (1) application of the transient code NLOOP; (2) unrestricted operator interaction including all simulator functions; (3) using the mainframe computer Control Data Cyber 176 in the KWU computing center; (4) four color graphic displays controlled by a dedicated graphic computer, no control room equipment; and (5) coupling of computers by telecommunication via telephone

  16. Nuclear Power Plants (Rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Lyerly, Ray L.; Mitchell III, Walter [Southern Nuclear Engineering, Inc.

    1973-01-01

    Projected energy requirements for the future suggest that we must employ atomic energy to generate electric power or face depletion of our fossil-fuel resources—coal, oil, and gas. In short, both conservation and economic considerations will require us to use nuclear energy to generate the electricity that supports our civilization. Until we reach the time when nuclear power plants are as common as fossil-fueled or hydroelectric plants, many people will wonder how the nuclear plants work, how much they cost, where they are located, and what kinds of reactors they use. The purpose of this booklet is to answer these questions. In doing so, it will consider only central station plants, which are those that provide electric power for established utility systems.

  17. Ferrous Metal Processing Plants

    Data.gov (United States)

    Department of Homeland Security — This map layer includes ferrous metal processing plants in the United States. The data represent commodities covered by the Minerals Information Team (MIT) of the...

  18. Nonferrous Metal Processing Plants

    Data.gov (United States)

    Department of Homeland Security — This map layer includes nonferrous metal processing plants in the United States. The data represent commodities covered by the Minerals Information Team (MIT) of the...

  19. Plutonium Finishing Plant

    Data.gov (United States)

    Federal Laboratory Consortium — The Plutonium Finishing Plant, also known as PFP, represented the end of the line (the final procedure) associated with plutonium production at Hanford.PFP was also...

  20. Plant Vascular Biology 2010

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Biao

    2014-11-17

    This grant supported the Second International Conference on Plant Vascular Biology (PVB 2010) held July 24-28, 2010 on the campus of Ohio State University, Columbus, Ohio. Biao Ding (Ohio State University; OSU) and David Hannapel (Iowa State University; ISU) served as co-chairs of this conference. Biao Ding served as the local organizer. PVB is defined broadly here to include studies on the biogenesis, structure and function of transport systems in plants, under conditions of normal plant growth and development as well as of plant interactions with pathogens. The transport systems cover broadly the xylem, phloem, plasmodesmata and vascular cell membranes. The PVB concept has emerged in recent years to emphasize the integrative nature of the transport systems and approaches to investigate them.

  1. Bituminization plant Jaslovske Bohunice

    International Nuclear Information System (INIS)

    1999-01-01

    In this leaflet the principle of the bituminization plant for radioactive concentrate (the intermediate liquid radioactive waste generated during the NPP A1, V-1, V-2 operations) solidification used in the Bohunice Radwaste Treatment Centre (BSC RAO) is presented

  2. Plant stem cell niches.

    Science.gov (United States)

    Aichinger, Ernst; Kornet, Noortje; Friedrich, Thomas; Laux, Thomas

    2012-01-01

    Multicellular organisms possess pluripotent stem cells to form new organs, replenish the daily loss of cells, or regenerate organs after injury. Stem cells are maintained in specific environments, the stem cell niches, that provide signals to block differentiation. In plants, stem cell niches are situated in the shoot, root, and vascular meristems-self-perpetuating units of organ formation. Plants' lifelong activity-which, as in the case of trees, can extend over more than a thousand years-requires that a robust regulatory network keep the balance between pluripotent stem cells and differentiating descendants. In this review, we focus on current models in plant stem cell research elaborated during the past two decades, mainly in the model plant Arabidopsis thaliana. We address the roles of mobile signals on transcriptional modules involved in balancing cell fates. In addition, we discuss shared features of and differences between the distinct stem cell niches of Arabidopsis.

  3. Biogas plants; Biogasanlagen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    Within the KRdL expert meeting at 30th October, 2012 in Bonn (Federal Republic of Germany), the following lectures were held: (1) New requirements on biomass conversion plants based on the Federal Nuisance Control Ordinance (Hans-Peter Ewens); (2) State of the art of the operation of biomass conversion plants (Christina Dornack); (3) Implementation of the regulation VDI 3475 sheet 4 (Markus Helm); (4) Handling of constraints of residents in the licensing procedure as well as during operation (Helmar Hentschke); (5) Explosion protection for biomass conversion plants considering the matters of immission control (Michael Faber); (6) Microbiological and epidemic-hygienic aspects of agricultural biomass conversion plants and their fermentation residues (Werner Philipp); (7) Emissions of climatic relevant gases at the biogas production (Jacqueline Daniel-Gromke); (8) State of the art in the biogas processing (Joachim Krassowski).

  4. Nuclear power plant construction

    International Nuclear Information System (INIS)

    Lima Moreira, Y.M. de.

    1979-01-01

    The legal aspects of nuclear power plant construction in Brazil, derived from governamental political guidelines, are presented. Their evolution, as a consequence of tecnology development is related. (A.L.S.L.) [pt

  5. Nuclear power plant decommissioning

    International Nuclear Information System (INIS)

    Yaziz Yunus

    1986-01-01

    A number of issues have to be taken into account before the introduction of any nuclear power plant in any country. These issues include reactor safety (site and operational), waste disposal and, lastly, the decommissioning of the reactor inself. Because of the radioactive nature of the components, nuclear power plants require a different approach to decommission compared to other plants. Until recently, issues on reactor safety and waste disposal were the main topics discussed. As for reactor decommissioning, the debates have been academic until now. Although reactors have operated for 25 years, decommissioning of retired reactors has simply not been fully planned. But the Shippingport Atomic Power Plant in Pennysylvania, the first large scale power reactor to be retired, is now being decommissioned. The work has rekindled the debate in the light of reality. Outside the United States, decommissioning is also being confronted on a new plane. (author)

  6. Advanced stellarator power plants

    International Nuclear Information System (INIS)

    Miller, R.L.

    1994-01-01

    The stellarator is a class of helical/toroidal magnetic fusion devices. Recent international progress in stellarator power plant conceptual design is reviewed and comparisons in the areas of physics, engineering, and economics are made with recent tokamak design studies

  7. Protoplasts and plant viruses

    International Nuclear Information System (INIS)

    Murakishi, H.; Lesney, M.S.; Carlson, P.

    1984-01-01

    The use of protoplasts in the study of plant viruses has attracted considerable attention since its inception in the late 1960s. This article is an attempt to assess the current status of protoplasts (primarily) and all cell cultures (in some instances) in studies of virus infection, virus replication, cytopathology, cross-protection, virus resistance, and the use of in vitro methods and genetic engineering to recover virus-resistant plants. These areas of study proved difficult to do entirely with whole plants or plant parts. However, because protoplasts could be synchronously infected with virus, they provided a valuable alternative means of following biochemical and cytological events in relation to the virus growth cycle in a more precise manner than previously possible

  8. Fertilization in Flowering Plants

    Indian Academy of Sciences (India)

    Ecology and the. Environment ... agents (pollinators), the next step before fertilization is to se- .... the embryo sac are referred to as pollen-pistil interaction and play ..... evolutionary success of flowering plants when compared to other groups of ...

  9. Competition between herbage plants

    NARCIS (Netherlands)

    Wit, de C.T.; Bergh, van den J.P.

    1965-01-01

    Starting from work with annuals a model of competition between herbage plants is discussed. It is shown that their mutual interference can only be described adequately if they are grown in mixture and also in monoculture

  10. Photomorphogenesis in plants

    National Research Council Canada - National Science Library

    Kendrick, Richard E; Kronenberg, G. H. M

    1994-01-01

    ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. ... VII VIII XXXI Part 1 Introduction 1. Introduction by Lars Olof Bjorn 1.1 1.2 1.3 1.4 1.5 1.6 A developing research field ... Plant vision...

  11. Reprocessing plants safety

    International Nuclear Information System (INIS)

    Davies, A.G.; Leighton, C.; Millington, D.

    1989-01-01

    The reprocessing of irradiated nuclear fuel at British Nuclear Fuels (BNFL) Sellafield site consists of a number of relatively self-contained activities carried out in separate plants across the site. The physical conditions and time scales applied in reprocessing and storage make it relatively benign. The potential for minor releases of radioactivity under fault conditioning is minimised by plant design definition of control procedures, training and supervision. The risks to both the general public and workforce are shown to be low with all the safety criteria being met. Normal operating conditions also have the potential for some occupational radiation exposure and the plant and workers are monitored continuously. Exposure levels have been reduced steadily and will continue to fall with plant improvements. (U.K.)

  12. International power plant business

    Energy Technology Data Exchange (ETDEWEB)

    Grohe, R.

    1986-03-03

    At the Brown Boveri press seminar 'Energy' in Baden-Baden Rainer Grohe, member of the Brown Boveri board, Mannheim, gave a survey of the activities on the international power plant market in recent years. He showed the vacuities which must be taken into account in this sector today. The drastic escalation of demands on power plant suppliers has lead not to a reduction of protagonists but to an increase. (orig.).

  13. Wind power plant

    Energy Technology Data Exchange (ETDEWEB)

    Caneghem, A.E. von

    1975-07-24

    The invention applies to a wind power plant in which the wind is used to drive windmills. The plant consists basically of a vertical tube with a lateral wind entrance opening with windmill on its lower end. On its upper end, the tube carries a nozzle-like top which increases the wind entering the tube by pressure decrease. The wind is thus made suitable for higher outputs. The invention is illustrated by constructional examples.

  14. Janata biogas plant

    Energy Technology Data Exchange (ETDEWEB)

    Bahadur, S; Singh, K K

    1980-03-01

    The Janata biogas plant is based on the use of local materials and locally available skills only. It is a proven technology at low cost and easy maintenance which should facilitate its extension at a much faster pace especially among the low income groups. This technology is important at this time because of the current crisis in the availability of firewood and mineral fuels. This handbook explains in non-technical language the basic features, design, and construction of this biogas plant. (DC)

  15. The plant mitochondrial proteome

    DEFF Research Database (Denmark)

    Millar, A.H.; Heazlewood, J.L.; Kristensen, B.K.

    2005-01-01

    The plant mitochondrial proteome might contain as many as 2000-3000 different gene products, each of which might undergo post-translational modification. Recent studies using analytical methods, such as one-, two- and three-dimensional gel electrophoresis and one- and two-dimensional liquid...... context to be defined for them. There are indications that some of these proteins add novel activities to mitochondrial protein complexes in plants....

  16. NMR, water and plants

    International Nuclear Information System (INIS)

    As, H. van.

    1982-01-01

    This thesis describes the application of a non-destructive pulsed proton NMR method mainly to measure water transport in the xylem vessels of plant stems and in some model systems. The results are equally well applicable to liquid flow in other biological objects than plants, e.g. flow of blood and other body fluids in human and animals. The method is based on a pulse sequence of equidistant π pulses in combination with a linear magnetic field gradient. (Auth.)

  17. Plant Formate Dehydrogenase

    Energy Technology Data Exchange (ETDEWEB)

    John Markwell

    2005-01-10

    The research in this study identified formate dehydrogenase, an enzyme that plays a metabolic role on the periphery of one-carbon metabolism, has an unusual localization in Arabidopsis thaliana and that the enzyme has an unusual kinetic plasticity. These properties make it possible that this enzyme could be engineered to attempt to engineer plants with an improved photosynthetic efficiency. We have produced transgenic Arabidopsis and tobacco plants with increased expression of the formate dehydrogenase enzyme to initiate further studies.

  18. Detergent zeolite filtration plant

    OpenAIRE

    Stanković Mirjana S.; Pezo Lato L.

    2003-01-01

    The IGPC Engineering Department designed basic projects for detergent zeolite filtration plant, using technology developed in the IGPC laboratories. Several projects were completed: technological, machine, electrical, automation. On the basis of these projects, a production plant with a capacity of 75,000 t/y was manufactured, at "Zeolite Mira", Mira (VE), Italy, in 1997, for increasing detergent zeolite production, from 50,000 to 100,000 t/y. The main goal was to increase the detergent zeoli...

  19. Modelling and simulation of the steam line, the high and low pressure turbines and the pressure regulator for the SUN-RAH nucleo electric university simulator; Modelado y simulacion de la linea de vapor, las turbinas de alta y de baja presion y el regulador de presion para el simulador universitario de nucleo electricas SUN RAH

    Energy Technology Data Exchange (ETDEWEB)

    Lopez R, A. [DEPFI, Campus Morelos, en IMTA Jiutepec, Morelos, UNAM (Mexico)]. e-mail: andyskamx@yahoo.com.mx

    2003-07-01

    In the following article the development of a simulator that allows to represent the dynamics of the following systems: steam line, nozzle, vapor separator, reheater, high pressure turbine, low pressure turbine, power generator and the pressure regulator of a nucleo electric power station. We start from the supposition that this plant will be modeled from a nuclear reactor type BWR (Boiling Water Reactor), using models of reduced order that represent the more important dynamic variables of the physical processes that happen along the steam line until the one generator. To be able to carry out the simulation in real time the Mat lab mathematical modeling software is used, as well as the specific simulation tool Simulink. It is necessary to point out that the platform on which the one is executed the simulator is the Windows operating system, to allow the intuitive use that only this operating system offers. The above-mentioned obeys to that the objective of the simulator it is to help the user to understand some of the dynamic phenomena that are present in the systems of a nuclear plant, and to provide a tool of analysis and measurement of variables to predict the desirable behavior of the same ones. The model of a pressure controller for the steam lines, the high pressure turbine and the low pressure turbine is also presented that it will be the one in charge of regulating the demand of the system according to the characteristics and critic restrictions of safety and control, assigned according to those wanted parameters of performance of this system inside the nucleo electric plant. This simulator is totally well defined and it is part of the University student nucleo electric simulator with Boiling Water Reactor (SUN-RAH), an integral project and of greater capacity. (Author)

  20. Plant extracts as radioprotectors

    Energy Technology Data Exchange (ETDEWEB)

    Baydoun, S; Al-Oudat, M [Atomic Energy Commission, Department of Radiation Protection and Nuclear Safety, Damascus (Syrian Arab Republic); Al-Achkar, W [Atomic Energy Commission, Department of Radiobiology and Health, Damascus (Syrian Arab Republic)

    1996-09-01

    Several studies show that the extracts of some plants, namely containing vitamins or sulfide components, have radioprotection properties against the effects of ionizing radiation. In Syria, many of hates plants are available. This experiment was conducted in order to test the ability of ten different plants to protect against the radiation damages. These plants are Daucus carota L., Brassica oleracea L, Aloe vera L., Opuntia ficus-indica, Allium cepa L., Capsicum annuum L., Scilla maritima L., Allium sativum L., Rubus sanctus L. and Rosa canina L.Their effects on the protection of E. Coli growth after the exposure to L.D 50 of gamma radiation (100 Gy) were investigated . Two concentrations to each plant extract were tested, both were than 1%. Our results are indicating that the protection depend on plant. The radioprotection factors were ranged between 1.42 to 2.39. The best results were obtained by using the extract of Allium sativum L. (2.01), Opuntia ficus-indica (2.14) and Capsiucum annuum L. (2.39). (author) 16 refs., 2 tabs., 4 figs.

  1. Medicinal plants of Lorestan

    Directory of Open Access Journals (Sweden)

    shahla ahmadi

    2010-03-01

    Full Text Available Collection and determination of medicinal plants in Lorestan province have been carried out for 6 years in the agriculture and natural resources research of center of Lorestan. The aims of this study were collection and identification the medicinal plans that grow in Loretta province, their distribution, habitat, traditional uses, utilized organ, manner of usage, botany specification, local name, Persian name and scientific name. Material and methods: Medicinal plants were collected from different regions by using field and library study for these goals we prepared a list of recorded medicinal plants from Lorestan, identified the local herbal experts. Results: Finally we collected 151 medicinal plant identified that related to 63 families and 90 genuses. The Lamiaceae, Compositae, Legominosae , Liliaceae, Umbelliferae and . Rosaceae are the greatest family in the Lorestan province. Diction: According to the literature 96 medicinal plans were recorded from Lorestan, but during this study we collected and identified 151 medicinal plants in Lorestan province. Comparing with those that recorded from Bushehr 70 sp.(9, Hormozgan 113 sp.(10, Markazi 144 sp. And Kordestan 144 sp(11. We have more diversity but comparing with Zanjan 163 sp.(13, Hamedan 315 sp.(14 And Qazvin 250 sp.(15 We have less diversity in medicinal plants.

  2. Plant extracts as radioprotectors

    International Nuclear Information System (INIS)

    Baydoun, S.; Al-Oudat, M.; Al-Achkar, W.

    1996-09-01

    Several studies show that the extracts of some plants, namely containing vitamins or sulfide components, have radioprotection properties against the effects of ionizing radiation. In Syria, many of hates plants are available. This experiment was conducted in order to test the ability of ten different plants to protect against the radiation damages. These plants are Daucus carota L., Brassica oleracea L, Aloe vera L., Opuntia ficus-indica, Allium cepa L., Capsicum annuum L., Scilla maritima L., Allium sativum L., Rubus sanctus L. and Rosa canina L.Their effects on the protection of E. Coli growth after the exposure to L.D 50 of gamma radiation (100 Gy) were investigated . Two concentrations to each plant extract were tested, both were than 1%. Our results are indicating that the protection depend on plant. The radioprotection factors were ranged between 1.42 to 2.39. The best results were obtained by using the extract of Allium sativum L. (2.01), Opuntia ficus-indica (2.14) and Capsiucum annuum L. (2.39). (author) 16 refs., 2 tabs., 4 figs

  3. Plant extracts as radioprotectors

    International Nuclear Information System (INIS)

    Baydoun, S.; Al-Oudat, M.; Al-Achkar, W.

    1997-01-01

    Several studies show that the extracts of some plants, namely containing vitamins or sulfide components, have radioprotection properties against the effects of ionizing radiation. In Syria, many of hates plants are available. This experiment was conducted in order to test the ability of ten different plants to protect against the radiation damages. These plants are Daucus carota L., Brassica oleracea L, Aloe vera L., Opuntia ficus-indica, Allium cepa L., Capsicum annuum L., Scilla maritima L., Allium sativum L., Rubus sanctus L. and Rosa canina L.Their effects on the protection of E. Coli growth after the exposure to L.D 50 of gamma radiation (100 Gy) were investigated . Two concentrations to each plant extract were tested, both were than 1%. Our results are indicating that the protection depend on plant. The radioprotection factors were ranged between 1.42 to 2.39. The best results were obtained by using the extract of Allium sativum L. (2.01), Opuntia ficus-indica (2.14) and Capsiucum annuum L. (2.39). (author)

  4. Power plants 2010. Lectures

    International Nuclear Information System (INIS)

    2010-01-01

    The proceedings include the following lectures: Facing the challenges - new structures for electricity production. Renewable energies in Europe - chances and challenges. Nuclear outlook in the UK. Sustainable energy for Europe. Requirements of the market and the grid operator at the electricity production companies. Perspectives for the future energy production. Pumped storage plants - status and perspectives. Nuclear power/renewable energies -partners or opponents? New fossil fired power stations in Europe - status and perspectives. Nuclear energy: outlook for new build and lifetime extension in Europe. Biomass in the future European energy market - experiences for dong energy. Meeting the EU 20:20 renewable energy targets: the offshore challenges. DESERTEC: sustainable electricity for Europe, Middle East and North Africa. New power plants in Europe - a challenge for project and quality management. Consideration of safely in new build activities of power plants. Challenges to an integrated development in Maasvlakte, Netherlands. Power enhancement in EnBW power plants. Operational experiences of CCS pilot plants worldwide. Two years of operational experiences with Vattenfall's oxyfuel pilot plant. Pre-conditions for CCS. Storage technologies for a volatile generation. Overview: new generation of gas turbines.

  5. Plant monitoring device

    International Nuclear Information System (INIS)

    Ito, Toru.

    1994-01-01

    The device of the present invention comprises a data collecting section for periodically collecting processed data sent from plant equipments, a top node induction and processing section for an important plant function model for inducing the plant function to be noted particularly by an operator from important plant function models by using process data and a window screen selection section for selecting a window screen to be displayed based on the result of the evaluation for each of function nodes based on the processing described above and determining the layout and automatically forming the display screen. It is constituted so that the kind and the layout of the window under display are checked if they are the same as those one cycle before or not and, if they are different, the screen is automatically switched to a new screen display. Then, operator's psychological burdens such as selection of information and judgement for the operation upon occurrence of plant abnormality and accident can be mitigated, to provide a safe operation circumstance having reinforced monitoring of the function of the whole plant can be provided. (N.H.)

  6. Uranium speciation in plants

    International Nuclear Information System (INIS)

    Guenther, A.; Bernhard, G.; Geipel, G.; Reich, T.; Rossberg, A.; Nitsche, H.

    2003-01-01

    Detailed knowledge of the nature of uranium complexes formed after the uptake by plants is an essential prerequisite to describe the migration behavior of uranium in the environment. This study focuses on the determination of uranium speciation after uptake of uranium by lupine plants. For the first time, time-resolved laser-induced fluorescence spectroscopy and X-ray absorption spectroscopy were used to determine the chemical speciation of uranium in plants. Differences were detected between the uranium speciation in the initial solution (hydroponic solution and pore water of soil) and inside the lupine plants. The oxidation state of uranium did not change and remained hexavalent after it was taken up by the lupine plants. The chemical speciation of uranium was identical in the roots, shoot axis, and leaves and was independent of the uranium speciation in the uptake solution. The results indicate that the uranium is predominantly bound as uranyl(VI) phosphate to the phosphoryl groups. Dandelions and lamb's lettuce showed uranium speciation identical to lupine plants. (orig.)

  7. Plant critical concept

    International Nuclear Information System (INIS)

    O'Regan, P.J.

    1996-01-01

    The objective of the effort summarized in this paper is to support O and M cost reduction efforts by focusing resources on components and processes critical to plant performance. This effort will identify where resources on nonplant critical components and processes can be reduced or eliminated. This method will use a functional assessment as the basis for component-specific evaluations and ranking. This effort consists of two stages conducted in series. The first stage is to deterministically identify that set of plant components that are relevant from a plant performance perspective (i.e., safety, economics, reliability). The second stage probabilistically ranks that set of plant components from an importance perspective, where importance pertains to the particular application and is probabilistically weighted. The results of a pilot study identified that only a relatively small set of components are truly critical from an integrated plant performance perspective. These results are consistent with work being conducted at other nuclear power plants, as well as other commercial facilities. Initial implementation of this effort is estimated to reduce O and M costs on the order of $1 million per year. Subsequent applications are anticipated to increase that savings to $4--$5 million per year

  8. Landscaping plant epigenetics.

    Science.gov (United States)

    McKeown, Peter C; Spillane, Charles

    2014-01-01

    The understanding of epigenetic mechanisms is necessary for assessing the potential impacts of epigenetics on plant growth, development and reproduction, and ultimately for the response of these factors to evolutionary pressures and crop breeding programs. This volume highlights the latest in laboratory and bioinformatic techniques used for the investigation of epigenetic phenomena in plants. Such techniques now allow genome-wide analyses of epigenetic regulation and help to advance our understanding of how epigenetic regulatory mechanisms affect cellular and genome function. To set the scene, we begin with a short background of how the field of epigenetics has evolved, with a particular focus on plant epigenetics. We consider what has historically been understood by the term "epigenetics" before turning to the advances in biochemistry, molecular biology, and genetics which have led to current-day definitions of the term. Following this, we pay attention to key discoveries in the field of epigenetics that have emerged from the study of unusual and enigmatic phenomena in plants. Many of these phenomena have involved cases of non-Mendelian inheritance and have often been dismissed as mere curiosities prior to the elucidation of their molecular mechanisms. In the penultimate section, consideration is given to how advances in molecular techniques are opening the doors to a more comprehensive understanding of epigenetic phenomena in plants. We conclude by assessing some opportunities, challenges, and techniques for epigenetic research in both model and non-model plants, in particular for advancing understanding of the regulation of genome function by epigenetic mechanisms.

  9. Plant monitoring device

    International Nuclear Information System (INIS)

    Moriyama, Kunio.

    1991-01-01

    The monitoring device of the present invention is most suitable to early detection for equipment abnormality, or monitoring of state upon transient conditions such as startup and shutdown of an electric power plant, a large-scaled thermonuclear device and an accelerator plant. That is, in existent moitoring devices, acquired data are stored and the present operation states are monitored in comparison. A plant operation aquisition data reproduction section is disposed to the device. From the past operation conditions stored in the plant operation data aquisition reproducing section, the number of operation cycles that agrees with the present plant operation conditions is sought, to determine the agreed aquired data. Since these aquired data are time sequential data measured based on the standard time determined by the operation sequence, aquired data can be reproduced successively on every sample pitches. With such a constitution, aquired data under the same operation conditions as the present conditions are displayed together with the measured data. Accordingly, accurate monitoring can be conducted from the start-up to the shutdown of the plant. (I.S.)

  10. Molecular plant volatile communication.

    Science.gov (United States)

    Holopainen, Jarmo K; Blande, James D

    2012-01-01

    Plants produce a wide array of volatile organic compounds (VOCs) which have multiple functions as internal plant hormones (e.g., ethylene, methyl jasmonate and methyl salicylate), in communication with conspecific and heterospecific plants and in communication with organisms of second (herbivores and pollinators) and third (enemies of herbivores) trophic levels. Species specific VOCs normally repel polyphagous herbivores and those specialised on other plant species, but may attract specialist herbivores and their natural enemies, which use VOCs as host location cues. Attraction of predators and parasitoids by VOCs is considered an evolved indirect defence, whereby plants are able to indirectly reduce biotic stress caused by damaging herbivores. In this chapter we review these interactions where VOCs are known to play a crucial role. We then discuss the importance of volatile communication in self and nonself detection. VOCs are suggested to appear in soil ecosystems where distinction of own roots from neighbours roots is essential to optimise root growth, but limited evidence of above-ground plant self-recognition is available.

  11. Conservation law of plants' energy value dependence of plants ...

    African Journals Online (AJOL)

    The plants differences in biochemical composition are analyzed, and the conservation law of energy value in plants is obtained. The link between the need for the nutrients and the plants biochemical composition is examined, Liebig's law is specified. Keywords: plant's biochemical composition, biochemistry, energy value in ...

  12. Chapter 15. Plant pathology and managing wildland plant disease systems

    Science.gov (United States)

    David L. Nelson

    2004-01-01

    Obtaining specific, reliable knowledge on plant diseases is essential in wildland shrub resource management. However, plant disease is one of the most neglected areas of wildland resources experimental research. This section is a discussion of plant pathology and how to use it in managing plant disease systems.

  13. Chemical signaling between plants and plant-pathogenic bacteria.

    Science.gov (United States)

    Venturi, Vittorio; Fuqua, Clay

    2013-01-01

    Studies of chemical signaling between plants and bacteria in the past have been largely confined to two models: the rhizobial-legume symbiotic association and pathogenesis between agrobacteria and their host plants. Recent studies are beginning to provide evidence that many plant-associated bacteria undergo chemical signaling with the plant host via low-molecular-weight compounds. Plant-produced compounds interact with bacterial regulatory proteins that then affect gene expression. Similarly, bacterial quorum-sensing signals result in a range of functional responses in plants. This review attempts to highlight current knowledge in chemical signaling that takes place between pathogenic bacteria and plants. This chemical communication between plant and bacteria, also referred to as interkingdom signaling, will likely become a major research field in the future, as it allows the design of specific strategies to create plants that are resistant to plant pathogens.

  14. Plants in alpine environments

    Science.gov (United States)

    Germino, Matthew J.

    2014-01-01

    Alpine and subalpine plant species are of special interest in ecology and ecophysiology because they represent life at the climate limit and changes in their relative abundances can be a bellwether for climate-change impacts. Perennial life forms dominate alpine plant communities, and their form and function reflect various avoidance, tolerance, or resistance strategies to interactions of cold temperature, radiation, wind, and desiccation stresses that prevail in the short growing seasons common (but not ubiquitous) in alpine areas. Plant microclimate is typically uncoupled from the harsh climate of the alpine, often leading to substantially warmer plant temperatures than air temperatures recorded by weather stations. Low atmospheric pressure is the most pervasive, fundamental, and unifying factor for alpine environments, but the resulting decrease in partial pressure of CO2 does not significantly limit carbon gain by alpine plants. Factors such as tree islands and topographic features create strong heterogeneous mosaics of microclimate and snow cover that are reflected in plant community composition. Factors affecting tree establishment and growth and formation of treeline are key to understanding alpine ecology. Carbohydrate and other carbon storage, rapid development in a short growing season, and physiological function at low temperature are prevailing attributes of alpine plants. A major contemporary research theme asks whether chilling at alpine-treeline affects the ability of trees to assimilate the growth resources and particularly carbon needed for growth or whether the growth itself is limited by the alpine environment. Alpine areas tend to be among the best conserved, globally, yet they are increasingly showing response to a range of anthropogenic impacts, such as atmospheric deposition.

  15. Advanced plant design recommendations from Cook Nuclear Plant experience

    International Nuclear Information System (INIS)

    Zimmerman, W.L.

    1993-01-01

    A project in the American Electric Power Service Corporation to review operating and maintenance experience at Cook Nuclear Plant to identify recommendations for advanced nuclear plant design is described. Recommendations so gathered in the areas of plant fluid systems, instrument and control, testing and surveillance provisions, plant layout of equipment, provisions to enhance effective maintenance, ventilation systems, radiological protection, and construction, are presented accordingly. An example for a design review checklist for effective plant operations and maintenance is suggested

  16. Japanese national reference reprocessing plant

    International Nuclear Information System (INIS)

    1978-08-01

    This paper gives a general description of the proposed Japanese national reprocessing plant and of the design philosophy. The plant is in most respects similar to the base case reprocessing plant, with an annual throughput of 100-1500 tU. The plant would be co-located with a fuel fabrication facility

  17. African names for American plants

    NARCIS (Netherlands)

    Andel, van T.R.

    2015-01-01

    African slaves brought plant knowledge to the New World, sometimes applying it to related plants they found there and sometimes bringing Old World plants with them. By tracing the linguistic parallels between names for plants in African languages and in communities descended from African slaves,

  18. Cadmium uptake by plants

    Energy Technology Data Exchange (ETDEWEB)

    Haghiri, F.

    1973-01-01

    Absorption of /sup 115m/Cd by soybean (Gylcine max l.) plants via foliar and root systems and translocation into the seed was determined. The uptake of /sup 115m/Cd by soybeans via the root system was more efficient than that of the foliar placement. Growth and Cd concentrations of soybean and wheat (Triticum aestivum l.) tops were influenced by soil-applied Cd. In both crops, the Cd concentration of plant tops increased while yield decreased with increasing levels of applied Cd. Cadmium toxicitiy began to occur in both crops at the lowest level of soil applied Cd (2.5 ppM). With soybean plants, Cd toxicity symptoms resembled fe chlorosis. For wheat plants there were no visual symptoms other than the studied growth. The relative concentration of Cd found in several vegetable crops varied depending on the plant species. The relative Cd concentration in descending order for various vegetables was lettuce (Lactuca sativa l.) > radish top (Raphanus sativus l.) > celery stalk (Apium graveolens l.) > celery leaves greater than or equal to green pepper (Capsicum frutescens l.) > radish roots.

  19. Plant critical concept

    International Nuclear Information System (INIS)

    O'Regan, P.J.

    1995-01-01

    The achievement of operation and maintenance (O ampersand M) cost reductions is a prime concern for plant operators. Initiatives by the nuclear industry to address this concern are under way and/or in development. These efforts include plant reliability studies, reliability-centered maintenance, risk ranking and testing philosophies, performance-based testing philosophies, graded quality assurance, and so forth. This paper presents the results of an effort to develop a methodology that integrates and applies the common data and analysis requirements for a number of risk-based and performance-based initiatives. This initial phase of the effort applied the methodology and its results to two initiatives. These were the procurement function and the preventive maintenance function. This effort integrated multiple programs and functions to identify those components that are truly critical from an integrated plant performance perspective. The paper describes the scope of the effort, the development of a methodology to identify plant critical components, and the application of these results to the maintenance rule compliance, preventive maintenance, and procurement functions at the candidate plant

  20. Benchmarking Nuclear Power Plants

    International Nuclear Information System (INIS)

    Jakic, I.

    2016-01-01

    One of the main tasks an owner have is to keep its business competitive on the market while delivering its product. Being owner of nuclear power plant bear the same (or even more complex and stern) responsibility due to safety risks and costs. In the past, nuclear power plant managements could (partly) ignore profit or it was simply expected and to some degree assured through the various regulatory processes governing electricity rate design. It is obvious now that, with the deregulation, utility privatization and competitive electricity market, key measure of success used at nuclear power plants must include traditional metrics of successful business (return on investment, earnings and revenue generation) as well as those of plant performance, safety and reliability. In order to analyze business performance of (specific) nuclear power plant, benchmarking, as one of the well-established concept and usual method was used. Domain was conservatively designed, with well-adjusted framework, but results have still limited application due to many differences, gaps and uncertainties. (author).

  1. Ornamental Plant Breeding

    Directory of Open Access Journals (Sweden)

    Flávia Barbosa Silva Botelho

    2015-04-01

    Full Text Available World’s ornamental plant market, including domestic market of several countries and its exports, is currently evaluated in 107 billion dollars yearly. Such estimate highlights the importance of the sector in the economy of the countries, as well as its important social role, as it represents one of the main activities, which contributes to income and employment. Therefore a well-structured plant breeding program, which is connected with consumers’ demands, is required in order to fulfill these market needs globally. Activities related to pre-breeding, conventional breeding, and breeding by biotechnological techniques constitute the basis for the successful development of new ornamental plant cultivars. Techniques that involve tissue culture, protoplast fusion and genetic engineering greatly aid conventional breeding (germplasm introduction, plant selection and hybridization, aiming the obtention of superior genotypes. Therefore it makes evident, in the literature, the successful employment of genetic breeding, since it aims to develop plants with commercial value that are also competitive with the ones available in the market.

  2. Plant arginyltransferases (ATEs

    Directory of Open Access Journals (Sweden)

    Tatiana Domitrovic

    Full Text Available Abstract Regulation of protein stability and/or degradation of misfolded and damaged proteins are essential cellular processes. A part of this regulation is mediated by the so-called N-end rule proteolytic pathway, which, in concert with the ubiquitin proteasome system (UPS, drives protein degradation depending on the N-terminal amino acid sequence. One important enzyme involved in this process is arginyl-t-RNA transferase, known as ATE. This enzyme acts post-translationally by introducing an arginine residue at the N-terminus of specific protein targets to signal degradation via the UPS. However, the function of ATEs has only recently begun to be revealed. Nonetheless, the few studies to date investigating ATE activity in plants points to the great importance of the ATE/N-end rule pathway in regulating plant signaling. Plant development, seed germination, leaf morphology and responses to gas signaling in plants are among the processes affected by the ATE/N-end rule pathway. In this review, we present some of the known biological functions of plant ATE proteins, highlighting the need for more in-depth studies on this intriguing pathway.

  3. Soft valves in plants

    Science.gov (United States)

    Park, Keunhwan; Tixier, Aude; Christensen, Anneline; Arnbjerg-Nielsen, Sif; Zwieniecki, Maciej; Jensen, Kaare

    2017-11-01

    Water and minerals flow from plant roots to leaves in the xylem, an interconnected network of vascular conduits that spans the full length of the organism. When a plant is subjected to drought stress, air pockets can spread inside the xylem, threatening the survival of the plant. Many plants prevent propagation of air by using hydrophobic nano-membranes in the ``pit'' pores that link adjacent xylem cells. This adds considerable resistance to flow. Interestingly, torus-margo pit pores in conifers are open and offer less resistance. To prevent propagation of air, conifers use a soft gating mechanism, which relies on hydrodynamic interactions between the xylem liquid and the elastic pit. However, it is unknown exactly how it is able to combine the seemingly antagonist functions of high permeability and resistance to propagation of air. We conduct experiments on biomimetic pores to elucidate the flow regulation mechanism. The design of plant valves is compared to other natural systems and optimal strategies are discussed. This work was supported by a research Grant (13166) from VILLUM FONDEN.

  4. AECL's plant Information Technologies

    International Nuclear Information System (INIS)

    DeVerno, M.; Lupton, L.; Didsbury, R.; Judd, R.

    1998-01-01

    The competitiveness of the world-wide energy market is a continual driving force for improvements to CANDU performance and lower operating, maintenance, and administration costs. As in other industries, advanced Information Technologies (IT) are changing the way we work and conduct business. The nuclear industry is no different and there exists strong incentives to improve work processes and provide faster and more flexible access to the information needed to effectively manage and maintain nuclear plant assets. AECL has responded to these forces through the development of a vision of integrated IT systems addressing all phases of nuclear plant development and operations. This includes the initial engineering, design, and construction processes as well as support to the long-term operations and maintenance. Integral to the AECL vision is the need for cost-effective engineering and operational configuration management systems, proactive maintenance processes and systems, and advanced plant surveillance and diagnostics. This paper presents the vision and describes the integrated information systems needed to manage both the design basis and operating plant data systems to ensure the cost-effective, long-term viability of CANDU plants. (author)

  5. Antidiabetic Plants of Iran

    Directory of Open Access Journals (Sweden)

    Ashrafeddin Goushegir

    2011-10-01

    Full Text Available To identify the antidiabetic plants of Iran, a systematic review of the published literature on the efficacy of Iranian medicinal plant for glucose control in patients with type 2 diabetes mellitus was conducted. We performed an electronic literature search of MEDLINE, Science Direct, Scopus, Proquest, Ebsco, Googlescholar, SID, Cochrane Library Database, from 1966 up to June 2010. The search terms were complementary and alternative medicine (CAM, diabetes mellitus, plant (herb, Iran, patient, glycemic control, clinical trial, RCT, natural or herbal medicine, hypoglycemic plants, and individual herb names from popular sources, or combination of these key words. Available Randomized Controlled Trials (RCT published in English or Persian language examined effects of an herb (limited to Iran on glycemic indexes in type 2 diabetic patients were included. Among all of the articles identified in the initial database search, 23 trials were RCT, examining herbs as potential therapy for type 2 diabetes mellitus. The key outcome for antidiabetic effect was changes in blood glucose or HbA1 c, as well as improves in insulin sensitivity or resistance. Available data suggest that several antidiabetic plants of Iran need further study. Among the RCT studies, the best evidence in glycemic control was found in Citrullus colocynthus, Ipomoea betatas, Silybum marianum and Trigonella foenum graecum.

  6. Geothermal Power Generation Plant

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya [Oregon Inst. of Technology, Klamath Falls, OR (United States). Geo-Heat Center

    2013-12-01

    Oregon Institute of Technology (OIT) drilled a deep geothermal well on campus (to 5,300 feet deep) which produced 196°F resource as part of the 2008 OIT Congressionally Directed Project. OIT will construct a geothermal power plant (estimated at 1.75 MWe gross output). The plant would provide 50 to 75 percent of the electricity demand on campus. Technical support for construction and operations will be provided by OIT’s Geo-Heat Center. The power plant will be housed adjacent to the existing heat exchange building on the south east corner of campus near the existing geothermal production wells used for heating campus. Cooling water will be supplied from the nearby cold water wells to a cooling tower or air cooling may be used, depending upon the type of plant selected. Using the flow obtained from the deep well, not only can energy be generated from the power plant, but the “waste” water will also be used to supplement space heating on campus. A pipeline will be construction from the well to the heat exchanger building, and then a discharge line will be construction around the east and north side of campus for anticipated use of the “waste” water by facilities in an adjacent sustainable energy park. An injection well will need to be drilled to handle the flow, as the campus existing injection wells are limited in capacity.

  7. Pinellas Plant facts

    International Nuclear Information System (INIS)

    1986-09-01

    This plant was built in 1956 in response to a need for the manufacture of neutron generators, a principal component in nuclear weapons. The neutron generators consist of a miniaturized linear ion accelerator assembled with the pulsed electrical power supplies required for its operation. The ion accelerator, or neutron tube, requires ultra clean, high vacuum technology: hermetic seals between glass, ceramic, glass-ceramic, and metal materials: plus high voltage generation and measurement technology. The existence of these capabilities at the Pinellas Plant has led directly to the assignment of the lightning arrester connector, specialty capacitor, vacuum switch, and crystal resonator. Active and reserve batteries and the radioisotopically-powered thermoelectric generator draw on the materials measurement and controls technologies which are required to ensure neutron generator life. A product development and production capability in alumina ceramics, cermet (electrical) feedthroughs, and glass ceramics has become a specialty of the plant; the laboratories monitor the materials and processes used by the plant's commercial suppliers of ferroelectric ceramics. In addition to the manufacturing facility, a production development capability is maintained at the Pinellas Plant

  8. Latina nuclear power plant

    International Nuclear Information System (INIS)

    1976-03-01

    In the period under review, the Latina power plant produced 1009,07 million kWh with a utilization factor of 72% and an availability factor of 80,51%. The disparity between the utilization and availability factors was mainly due to the shutdown of the plant owing to trade union strife. The reasons for non-availability (19,49%) were almost all related to the functioning of the conventional part and the general servicing of the plant (18 September-28 October). During the shutdown for maintenance, an inspection of the steel members and parts of the core stabilizing structure was made in order to check for the familiar oxidation phenomena caused by CO 2 ; the results of the inspection were all satisfactory. Operation of the plant during 1974 was marked by numerous power cutbacks as a result of outages of the steam-raising units (leaks from the manifolds) and main turbines (inspection and repairs to the LP rotors). Since it was first brought into commercial operation, the plant has produced 13,4 thousand million kWh

  9. Plants cultivation in controlled containments

    International Nuclear Information System (INIS)

    2000-01-01

    The plants cultivation in controlled containments permits to the - Departement d'Ecophysiologie Vegetale et de Microbiologie (DVEM) - of the CEA to lead several topics of research. The works of DVEM which are based on the molecular labelling, technique adapted to plants, contribute to understand the plant - soil relationships and the plant growth process. In addition, the staff of DVEM study the impact of pollutant heavy metals, existing in the soil, on plants and the plant stress induced by oxygen, light, ionizing radiations,... and defence mechanisms of plants (F. M.)

  10. Owners of nuclear power plants

    International Nuclear Information System (INIS)

    Wood, R.S.

    1991-07-01

    This report indicates percentage ownership of commercial nuclear power plants by utility companies. The report includes all plants operating, under construction, docketed for NRC safety and environmental reviews, or under NRC antitrust review, but does not include those plants announced but not yet under review or those plants formally cancelled. Part 1 of the report lists plants alphabetically with their associated applicants or licensees and percentage ownership. Part 2 lists applicants or licensees alphabetically with their associated plants and percentage ownership. Part 1 also indicates which plants have received operating licenses (OLS)

  11. Asociacion Espanola de la Industria Electrica (UNESA) annual report 2006. Information about electricity activities; Asociacion Espanola de la Industria Electrica UNESA 2006 memoria estadistica. Informe sobre las actividades electricas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    The annual report of UNESA, the industrial grouping of major power companies in Spain, gives statistical data relating to power generation, transmission and distribution and a summary of achievements during 2006. Power is generated from fossil fuel, nuclear, and hydro power. Cooperation of UNESA with international organizations is reported. Detailed figures are given for electricity production during the year. A summary of the report is available in English and Spanish on the website www.unesa.es.

  12. PV power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    Within the international seminar of the Ostbayerisches Technologie-Transfer-Institut e.V. (OTTI) at 11th June, 2012 in Munich (Federal Republic of Germany), the following lectures were held: (1) Technical due diligence (Dietmar Obst); (2) Certification / rating system for large PV plants (Robert Pfatischer); (3) O and M requirements (Lars Rulf); (4) IR photography for large scale systems (Bernhard Weinreich); (5) New market models for PV systems - direct marketing and sales of PV electricity (Martin Schneider); (6) Needs and benefits for plant certification for grid connection and operation (Christoph Luetke-Lengerich); (7) Lare volume module testing / Screening in the field and workshop (Semir Merzoug); (8) Dismantling costs of large scale PV plants (Siegfried Schimpf).

  13. Plant redox proteomics

    DEFF Research Database (Denmark)

    Navrot, Nicolas; Finnie, Christine; Svensson, Birte

    2011-01-01

    PTMs in regulating enzymatic activities and controlling biological processes in plants. Notably, proteins controlling the cellular redox state, e.g. thioredoxin and glutaredoxin, appear to play dual roles to maintain oxidative stress resistance and regulate signal transduction pathways via redox PTMs......In common with other aerobic organisms, plants are exposed to reactive oxygen species resulting in formation of post-translational modifications related to protein oxidoreduction (redox PTMs) that may inflict oxidative protein damage. Accumulating evidence also underscores the importance of redox....... To get a comprehensive overview of these types of redox-regulated pathways there is therefore an emerging interest to monitor changes in redox PTMs on a proteome scale. Compared to some other PTMs, e.g. protein phosphorylation, redox PTMs have received less attention in plant proteome analysis, possibly...

  14. Collective biogas plants

    International Nuclear Information System (INIS)

    1992-01-01

    Papers contributed to the European seminar on collective biogas plants held at Herning, Denmark on October 22-23 under the auspices of the Commission of the European Communities, Directorate-General for Energy (DG XVII) are presented. Within the framework of the THERMIE programme, a network of OPETs (Organizations for the Promotion of Energy Technologies) was set up in order to disseminate information on new energy technologies throughout the European communities. The potential for further implementation of centralized capacity for the conversion of animal manures and other organic wastes to bio-fuels, not only in central and eastern Europe but also in the developing countries, is discussed in addition to the relevant technologies. Actual biomass conversion plants are described and details are given on operational experience and plant management. Agricultural, economic and policy aspects are also dealt with. (AB)

  15. Town gas plants

    International Nuclear Information System (INIS)

    Anastos, G.J.; Johnson, G.M.; Schapot, R.M.; Velez, V.G.

    1990-01-01

    Town gas plant sites are receiving increasing attention from the utility industry and regulatory communities. This attention has been prompted by greater environmental awareness of impacts due to past disposal practices and the understanding that gas plant wastes contain a wide range of chemical constituents that have persisted in the environment. This paper discusses the history of the town gas plant industry, the various processes utilized and the resultant by-products and wastes. Potential problem areas relating to these sites as well as potential approaches to site characterization are addressed. Included are recommendations for the phasing of site investigations and the use of relatively inexpensive and rapid field screening techniques to identify contamination

  16. Plant stem cell niches.

    Science.gov (United States)

    Stahl, Yvonne; Simon, Rüdiger

    2005-01-01

    Stem cells are required to support the indeterminate growth style of plants. Meristems are a plants stem cell niches that foster stem cell survival and the production of descendants destined for differentiation. In shoot meristems, stem cell fate is decided at the populational level. The size of the stem cell domain at the meristem tip depends on signals that are exchanged with cells of the organizing centre underneath. In root meristems, individual stem cells are controlled by direct interaction with cells of the quiescent centre that lie in the immediate neighbourhood. Analysis of the interactions and signaling processes in the stem cell niches has delivered some insights into the molecules that are involved and revealed that the two major niches for plant stem cells are more similar than anticipated.

  17. Nuclear plant life extension

    International Nuclear Information System (INIS)

    Negin, C.A.

    1989-01-01

    The nuclear power industry's addressing of life extension is a natural trend in the maturation of this technology after 20 years of commercial operation. With increasing emphasis on how plants are operated, and less on how to build them, attention is turning on to maximizing the use of these substantial investments. The first studies of life extension were conducted in the period from 1978 and 1982. These were motivated by the initiation, by the Nuclear Regulatory Commission (NRC), of studies to support decommissioning rulemaking. The basic conclusions of those early studies that life extension is feasible and worth pursuing have not been changed by the much more extensive investigations that have since been conducted. From an engineering perspective, life extension for nuclear plants is fundamentally the same as for fossil plants

  18. Individual plant examination: Submittal guidance

    International Nuclear Information System (INIS)

    1989-08-01

    Based on a Policy Statement on Severe Accidents Regarding Future Designs and Existing Plants, the performance of a plant examination is requested from the licensee of each nuclear power plant. The plant examination looks for vulnerabilities to severe accidents and cost-effective safety improvements that reduce or eliminate the important vulnerabilities. This document delineates guidance for reporting the results of that plant examination. 38 refs., 2 tabs

  19. Urea metabolism in plants.

    Science.gov (United States)

    Witte, Claus-Peter

    2011-03-01

    Urea is a plant metabolite derived either from root uptake or from catabolism of arginine by arginase. In agriculture, urea is intensively used as a nitrogen fertilizer. Urea nitrogen enters the plant either directly, or in the form of ammonium or nitrate after urea degradation by soil microbes. In recent years various molecular players of plant urea metabolism have been investigated: active and passive urea transporters, the nickel metalloenzyme urease catalyzing the hydrolysis of urea, and three urease accessory proteins involved in the complex activation of urease. The degradation of ureides derived from purine breakdown has long been discussed as a possible additional metabolic source for urea, but an enzymatic route for the complete hydrolysis of ureides without a urea intermediate has recently been described for Arabidopsis thaliana. This review focuses on the proteins involved in plant urea metabolism and the metabolic sources of urea but also addresses open questions regarding plant urea metabolism in a physiological and agricultural context. The contribution of plant urea uptake and metabolism to fertilizer urea usage in crop production is still not investigated although globally more than half of all nitrogen fertilizer is applied to crops in the form of urea. Nitrogen use efficiency in crop production is generally well below 50% resulting in economical losses and creating ecological problems like groundwater pollution and emission of nitric oxides that can damage the ozone layer and function as greenhouse gasses. Biotechnological approaches to improve fertilizer urea usage bear the potential to increase crop nitrogen use efficiency. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  20. Ion channels in plants.

    Science.gov (United States)

    Hedrich, Rainer

    2012-10-01

    Since the first recordings of single potassium channel activities in the plasma membrane of guard cells more than 25 years ago, patch-clamp studies discovered a variety of ion channels in all cell types and plant species under inspection. Their properties differed in a cell type- and cell membrane-dependent manner. Guard cells, for which the existence of plant potassium channels was initially documented, advanced to a versatile model system for studying plant ion channel structure, function, and physiology. Interestingly, one of the first identified potassium-channel genes encoding the Shaker-type channel KAT1 was shown to be highly expressed in guard cells. KAT1-type channels from Arabidopsis thaliana and its homologs from other species were found to encode the K(+)-selective inward rectifiers that had already been recorded in early patch-clamp studies with guard cells. Within the genome era, additional Arabidopsis Shaker-type channels appeared. All nine members of the Arabidopsis Shaker family are localized at the plasma membrane, where they either operate as inward rectifiers, outward rectifiers, weak voltage-dependent channels, or electrically silent, but modulatory subunits. The vacuole membrane, in contrast, harbors a set of two-pore K(+) channels. Just very recently, two plant anion channel families of the SLAC/SLAH and ALMT/QUAC type were identified. SLAC1/SLAH3 and QUAC1 are expressed in guard cells and mediate Slow- and Rapid-type anion currents, respectively, that are involved in volume and turgor regulation. Anion channels in guard cells and other plant cells are key targets within often complex signaling networks. Here, the present knowledge is reviewed for the plant ion channel biology. Special emphasis is drawn to the molecular mechanisms of channel regulation, in the context of model systems and in the light of evolution.

  1. Integrated Gasification SOFC Plant with a Steam Plant

    DEFF Research Database (Denmark)

    Rokni, Masoud; Pierobon, Leonardo

    2011-01-01

    A hybrid Solid Oxide Fuel Cell (SOFC) and Steam Turbine (ST) plant is integrated with a gasification plant. Wood chips are fed to the gasification plant to produce biogas and then this gas is fed into the anode side of a SOFC cycle to produce electricity and heat. The gases from the SOFC stacks...... enter into a burner to burn the rest of the fuel. The offgases after the burner are now used to generate steam in a Heat Recovery Steam Generator (HRSG). The generated steam is expanded in a ST to produce additional power. Thus a triple hybrid plant based on a gasification plant, a SOFC plant...... and a steam plant is presented and studied. The plant is called as IGSS (Integrated Gasification SOFC Steam plant). Different systems layouts are presented and investigated. Electrical efficiencies up to 56% are achieved which is considerably higher than the conventional integrated gasification combined...

  2. Plant biotechnology: transgenic crops.

    Science.gov (United States)

    Shewry, Peter R; Jones, Huw D; Halford, Nigel G

    2008-01-01

    Transgenesis is an important adjunct to classical plant breeding, in that it allows the targeted manipulation of specific characters using genes from a range of sources. The current status of crop transformation is reviewed, including methods of gene transfer, the selection of transformed plants and control of transgene expression. The application of genetic modification technology to specific traits is then discussed, including input traits relating to crop production (herbicide tolerance and resistance to insects, pathogens and abiotic stresses) and output traits relating to the composition and quality of the harvested organs. The latter include improving the nutritional quality for consumers as well as the improvement of functional properties for food processing.

  3. Wind power plant

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, G

    1975-11-20

    A wind power plant is proposed suitable for electicity generation or water pumping. This plant is to be self-adjusting to various wind velocities and to be kept in operation even during violent storms. For this purpose the mast, carrying the wind rotor and pivotable around a horizontal axis is tiltable and equipped with a wind blind. Further claims contain various configurations of the tilting base resp. the cut in of an elastic link, the attachment and design of the wind blind as well as the constructive arrangement of one or more dynamos.

  4. Power plant process computer

    International Nuclear Information System (INIS)

    Koch, R.

    1982-01-01

    The concept of instrumentation and control in nuclear power plants incorporates the use of process computers for tasks which are on-line in respect to real-time requirements but not closed-loop in respect to closed-loop control. The general scope of tasks is: - alarm annunciation on CRT's - data logging - data recording for post trip reviews and plant behaviour analysis - nuclear data computation - graphic displays. Process computers are used additionally for dedicated tasks such as the aeroball measuring system, the turbine stress evaluator. Further applications are personal dose supervision and access monitoring. (orig.)

  5. Savannah River Plant environment

    International Nuclear Information System (INIS)

    Dukes, E.K.

    1984-03-01

    On June 20, 1972, the Atomic Energy Commission designated 192,323 acres of land near Aiken, SC, as the nation's first National Environmental Research Park. The designated land surrounds the Department of Energy's Savannah River Plant production complex. The site, which borders the Savannah River for 17 miles, includes swampland, pine forests, abandoned town sites, a large man-made lake for cooling water impoundment, fields, streams, and watersheds. This report is a description of the geological, hydrological, meteorological, and biological characteristics of the Savannah River Plant site and is intended as a source of information for those interested in environmental research at the site. 165 references, 68 figures, 52 tables

  6. Quantitative plant ecology

    DEFF Research Database (Denmark)

    Damgaard, Christian

    2014-01-01

    This e-book is written in the Wolfram' CDF format (download free CDF player from Wolfram.com) The objective of this e-book is to introduce the population ecological concepts for measuring and predicting the ecological success of plant species. This will be done by focusing on the measurement...... and statistical modelling of plant species abundance and the relevant ecological processes that control species abundance. The focus on statistical modelling and likelihood function based methods also means that more algorithm based methods, e.g. ordination techniques and boosted regression tress...

  7. PLANTS, SOURCE FOR BIOFUELS

    Directory of Open Access Journals (Sweden)

    Irina Ramona PECINGINĂ

    2016-12-01

    Full Text Available The most affordable alternative energy sources to fossil plants with hydropower are some oils that accumulate in different organs other accumulating carbohydrates with high energy value. They are known worldwide and cultivated a number of plant species entering the oilseeds, which provides significant production of edible oil (soybean, sunflower, etc. Vegetable oils or their product derived biodiesel fuels are potential diesel engines, representing an alternative to fuels. The most promising suitable for the production of oil crops "with short circuit "or biodiesel are fruits and seeds, both herbaceous and tree.

  8. ITER plant systems

    International Nuclear Information System (INIS)

    Kolbasov, B.; Barnes, C.; Blevins, J.

    1991-01-01

    As part of a series of documents published by the IAEA that summarize the results of the Conceptual Design Activities for the ITER project, this publication describes the conceptual design of the ITER plant systems, in particular (i) the heat transport system, (ii) the electrical distribution system, (iii) the requirements for radioactive equipment handling, the hot cell, and waste management, (iv) the supply system for fluids and operational chemicals, (v) the qualitative analyses of failure scenarios and methods of burn stability control and emergency shutdown control, (vi) analyses of tokamak building functions and design requirements, (vii) a plant layout, and (viii) site requirements. Refs, figs and tabs

  9. Fossil power plant automation

    International Nuclear Information System (INIS)

    Divakaruni, S.M.; Touchton, G.

    1991-01-01

    This paper elaborates on issues facing the utilities industry and seeks to address how new computer-based control and automation technologies resulting from recent microprocessor evolution, can improve fossil plant operations and maintenance. This in turn can assist utilities to emerge stronger from the challenges ahead. Many presentations at the first ISA/EPRI co-sponsored conference are targeted towards improving the use of computer and control systems in the fossil and nuclear power plants and we believe this to be the right forum to share our ideas

  10. Plant engineering network

    International Nuclear Information System (INIS)

    Angus, M.J.; Goossen, J.

    1996-01-01

    The Plant Engineering Network (PEN) is a utility-vendor relationship focussed on reducing O and M costs, while maintaining the safe and reliable operation of partner plants through sharing resources, using telecommunications systems for collaborative engineering, coordinating and streamlining work processes, and sharing financial risk and reward. This paper examines how Pacific Gas and Electric (PG and E) established a PEN organization and realized over =0.5 million U.S. in 1994, the first year of implementation, and approximately =2 million U.S. savings in 1995. (author)

  11. Total Logistic Plant Solutions

    Directory of Open Access Journals (Sweden)

    Dusan Dorcak

    2016-02-01

    Full Text Available The Total Logistics Plant Solutions, plant logistics system - TLPS, based on the philosophy of advanced control processes enables complex coordination of business processes and flows and the management and scheduling of production in the appropriate production plans and planning periods. Main attributes of TLPS is to create a comprehensive, multi-level, enterprise logistics information system, with a certain degree of intelligence, which accepts the latest science and research results in the field of production technology and logistics. Logistic model of company understands as a system of mutually transforming flows of materials, energy, information, finance, which is realized by chain activities and operations

  12. Methylome evolution in plants.

    Science.gov (United States)

    Vidalis, Amaryllis; Živković, Daniel; Wardenaar, René; Roquis, David; Tellier, Aurélien; Johannes, Frank

    2016-12-20

    Despite major progress in dissecting the molecular pathways that control DNA methylation patterns in plants, little is known about the mechanisms that shape plant methylomes over evolutionary time. Drawing on recent intra- and interspecific epigenomic studies, we show that methylome evolution over long timescales is largely a byproduct of genomic changes. By contrast, methylome evolution over short timescales appears to be driven mainly by spontaneous epimutational events. We argue that novel methods based on analyses of the methylation site frequency spectrum (mSFS) of natural populations can provide deeper insights into the evolutionary forces that act at each timescale.

  13. Power plants 2009. Lectures

    International Nuclear Information System (INIS)

    2009-01-01

    Within the Annual Conference 2009 of the VGB PowerTech e.V. (Essen, Federal Republic of Germany) from 23rd to 25th May, 2009, in Lyon (France) the following lectures were held: (1) Electricity demand, consequences of the financial and economic crisis - Current overview 2020 for the EU-27 (Hans ten Berge); (2) Status and perspectives of the electricity generation mix in France (Bernard Dupraz); (3) European electricity grid - status and perspective (Dominique Maillard); (4) Technologies and acceptance in the European energy market (Gordon MacKerran); (5) EPR construction in Finland, China, France, (Claude Jaouen); (6) EPR Flamanville 3: A project on the path towards nuclear revival (Jacques Alary); (7) Worldwide nuclear Revival and acceptance (Luc Geraets); (8) An overview on the status of final disposal of radioactive wastes worldwide (Piet Zuidema); (9) Who needs pumped storage plants? PSP are partner to grid stability and renewable energies (Hans-Christoph Funke); (10) Sustainable use of water resources to generate electricity safely and efficiently (Patrick Tourasse); (11) The growth strategy of RWE Innogy - Role of RES in RWE strategy (Fritz Vahrenholt); (12) Solar technologies towards grid parity - key factors and timeframe (G. Gigliucci); (13) Overview on CCS technologies and results of Vattenfalls oxyfuel pilot plant (Philippe Paelinck); (14) Development perspectives of lignite-based IGCC-plants with CCS (Dietmar Keller); (15) Post combustion capture plants - concept and plant integration (Wolfgang Schreier); (16) CCS fossil power generation in a carbon constraint world (Daniel Hofmann); (17) CEZ group strategy in Central and South Eastern Europe (Jan Zizka); (18) Strategy and projects of DONG Energy (Jens Erik Pedersen); (19) E.ON coal-based power generation of the future - The highly efficient power plant and downstream separation of carbon dioxide (Gerhard Seibel); (20) Final sage of first supercritical 460 MW e l. CFB Boiler construction - firs

  14. Wind power plant

    Energy Technology Data Exchange (ETDEWEB)

    Kling, A

    1977-01-13

    The wind power plant described has at least one rotor which is coupled to an electricity generator. The systems are fixed to a suspended body so that it is possible to set up the wind power plant at greater height where one can expect stronger and more uniform winds. The anchoring on the ground or on a floating body is done by mooring cables which can simultaneously have the function of an electric cable. The whole system can be steered by fins. The rotor system itself consists of at least one pair of contrarotating, momentum balanced rotors.

  15. Conceptualizing Pharmaceutical Plants

    DEFF Research Database (Denmark)

    Larsen, Bent Dalgaard; Jensen, Klaes Ladeby; Gjøl, Mikkel

    2006-01-01

    In the conceptual design phase of pharmaceutical plants as much as 80%-90% of the total cost of a project is committed. It is therefore essential that the chosen concept is viable. In this design process configuration and 3D models can help validate the decisions made. Designing 3D models...... is a complex task and requires skilled users. We demonstrate that a simple 2D/3D configuration tool can support conceptualizing of pharmaceutical plants. Present paper reports on preliminary results from a full scale implementation project at a Danish engineering company....

  16. Ardennes nuclear power plant

    International Nuclear Information System (INIS)

    1974-12-01

    The SENA nuclear power plant continued to operate, as before, at authorized rated power, namely 905MWth during the first half year and 950MWth during the second half year. Net energy production:2028GWh; hours phased to the line: 7534H; availability factor: 84%; utilization factor: 84%; total shutdowns:19; number of scrams:10; cost per KWh: 4,35 French centimes. Overall, the plant is performing very satisfactory. Over the last three years net production has been 5900GWh, corresponding to in average utilization factor of 83%

  17. Nuclear power plant

    International Nuclear Information System (INIS)

    Orlov, V.V.; Rineisky, A.A.

    1975-01-01

    The invention is aimed at designing a nuclear power plant with a heat transfer system which permits an accelerated fuel regeneration maintaining relatively high initial steam values and efficiency of the steam power circuit. In case of a plant with three circuits the secondary cooling circuit includes a steam generator with preheater, evaporator, steam superheater and intermediate steam superheater. At the heat supply side the latter is connected with its inlet to the outlet of the evaporator and with its outlet to the low-temperature side of the secondary circuit

  18. Monitoring wood heating plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The overall aim of the project is to support the increased use of biomass heating plant in the UK by improving the quality and quantity of information available to suppliers and users. This aim will be achieved by: providing a qualitative assessment of the operational performance of a representative range of biomass heating installations including summaries of technical information; providing good case studies for a range of installations addressing the varied market demands; collating performance data of existing installations so as to improve the performance and/or reduce capital and operating costs of existing and future installations; and providing basic operator training and recommending methods optimising/improving plant performance. (author)

  19. Apoplastic interactions between plants and plant root intruders

    Directory of Open Access Journals (Sweden)

    Kanako eMitsumasu

    2015-08-01

    Full Text Available Numerous pathogenic or parasitic organisms attack plant roots to obtain nutrients, and the apoplast including the plant cell wall is where the plant cell meets such organisms. Root-parasitic angiosperms and nematodes are two distinct types of plant root parasites but share some common features in their strategies for breaking into plant roots. Striga and Orobanche are obligate root parasitic angiosperms that cause devastating agricultural problems worldwide. Parasitic plants form an invasion organ called a haustorium, where plant cell wall degrading enzymes (PCWDEs are highly expressed. Plant-parasitic nematodes are another type of agriculturally important plant root parasite. These nematodes breach the plant cell walls by protruding a sclerotized stylet from which PCWDEs are secreted. Responding to such parasitic invasion, host plants activate their own defense responses against parasites. Endoparasitic nematodes secrete apoplastic effectors to modulate host immune responses and to facilitate the formation of a feeding site. Apoplastic communication between hosts and parasitic plants also contributes to their interaction. Parasitic plant germination stimulants, strigolactones (SLs, are recently identified apoplastic signals that are transmitted over long distances from biosynthetic sites to functioning sites. Here, we discuss recent advances in understanding the importance of apoplastic signals and cell walls for plant-parasite interactions.

  20. Apoplastic interactions between plants and plant root intruders.

    Science.gov (United States)

    Mitsumasu, Kanako; Seto, Yoshiya; Yoshida, Satoko

    2015-01-01

    Numerous pathogenic or parasitic organisms attack plant roots to obtain nutrients, and the apoplast including the plant cell wall is where the plant cell meets such organisms. Root parasitic angiosperms and nematodes are two distinct types of plant root parasites but share some common features in their strategies for breaking into plant roots. Striga and Orobanche are obligate root parasitic angiosperms that cause devastating agricultural problems worldwide. Parasitic plants form an invasion organ called a haustorium, where plant cell wall degrading enzymes (PCWDEs) are highly expressed. Plant-parasitic nematodes are another type of agriculturally important plant root parasite. These nematodes breach the plant cell walls by protruding a sclerotized stylet from which PCWDEs are secreted. Responding to such parasitic invasion, host plants activate their own defense responses against parasites. Endoparasitic nematodes secrete apoplastic effectors to modulate host immune responses and to facilitate the formation of a feeding site. Apoplastic communication between hosts and parasitic plants also contributes to their interaction. Parasitic plant germination stimulants, strigolactones, are recently identified apoplastic signals that are transmitted over long distances from biosynthetic sites to functioning sites. Here, we discuss recent advances in understanding the importance of apoplastic signals and cell walls for plant-parasite interactions.

  1. Energy efficiency and restructuring of the Brazilian power sector

    Energy Technology Data Exchange (ETDEWEB)

    De Martino Jannuzzi, Gilberto [State University of Campinas, Sao Paulo, (Brazil)

    1999-07-01

    Since the early nineties Brazil has initiated a program of reforms in its electric sector which includes utility privatization, de-verticalization. The main objectives were to promote a market-oriented energy industry attractive to private investments. This has led to the loss of sponsorship for the public-interest programs formerly undertaken by the state utilities. In particular, of significant concern are the programs for promotion of energy efficiency, renewable energy technologies, rural electrification and environmental protection. In the midst of the privatization effort, the National Agency for Electrical Energy ANEEL was created (end of 1997). One of the tasks of the regulatory agency is to provide funds and incentives to energy conservation. In this paper we review the role of ANEEL in promoting energy efficiency investments in the context of a market-oriented sector, its limitations and prospects. [Spanish] Desde principios de los anos noventa Brasil ha iniciado un programa de reformas en su sector electrico que incluye la privatizacion del servicio electrico y la desverticalizacion. Los objetivos principales eran promover una industria de la energia orientada comercialmente de la energia electrica, atractiva a las inversiones privadas. Esto ha conducido a la perdida de patrocinio de los programas de interes publico emprendidos antes por las empresas electricas del estado. En particular, de preocupacion significativa estan los programas para la promocion del rendimiento energetico, de las tecnologias de la energia renovable, de la Electrificacion rural y de la proteccion del medio ambiente. En medio del esfuerzo de la privatizacion, la agencia nacional para la energia electrica ANEEL fue creada (finales de 1997). Una de las tareas de la agencia reguladora es proporcionar fondos e incentivos a la conservacion de energia. En este trabajo repasamos el papel de ANEEL en promover inversiones del rendimiento energetico en el contexto de un sector orientado

  2. B Plant hazards assessment

    International Nuclear Information System (INIS)

    Broz, R.E.

    1994-01-01

    This document establishes the technical basis in support of Emergency Planning Activities for B Plant on the Hanford Site. The document represents an acceptable interpretation of the implementing guidance document for DOE Order 5500.3A. Through this document, the technical basis for the development of facility specific , Emergency Action Levels and the Emergency Planning Zone is demonstrated

  3. Nuclear power plant analyzer

    International Nuclear Information System (INIS)

    Stritar, A.

    1986-01-01

    The development of Nuclear Power Plant Analyzers in USA is described. There are two different types of Analyzers under development in USA, the forst in Idaho and Los Alamos national Lab, the second in brookhaven National lab. That one is described in detail. The computer hardware and the mathematical models of the reactor vessel thermalhydraulics are described. (author)

  4. Plant research '76

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    Overall objective remains unchanged: to contribute to the knowledge, with strong emphasis on fundamental problems, of how plants function, the roles they play in the environment and energy relations of the world, and how these roles may be optimized for the benefit of mankind. (PCS)

  5. Drought Signaling in Plants

    Indian Academy of Sciences (India)

    depending upon the source and nature of signaling: (i) hormone signal, (ii) .... plants to regulate the rate of transpiration through minor structural .... cell has to keep spending energy (in the form of A TP) to maintain a .... enzymes and proteins in the regulation of cellular metabolism can be determined by either inactivating.

  6. Nuclear power plant

    International Nuclear Information System (INIS)

    Wieser, R.

    1979-01-01

    The reactor pressure vessel consists of two parts. A cylindrical lower part with a hemispherical steel roof is placed at some distance within an equally shaped pressure vessel of concrete. Both vessels are standing on a common bottom plate. The interspace is kept at subpressure. It serves to contain ring galleries, elevator shafts, and power plant components. (GL) [de

  7. Recombinant Cytokines from Plants

    Czech Academy of Sciences Publication Activity Database

    Sirko, A.; Vaněk, Tomáš; Gora-Sochacka, A.; Redkiewicz, P.

    2011-01-01

    Roč. 12, č. 6 (2011), s. 3536-3552 ISSN 1661-6596 Institutional research plan: CEZ:AV0Z50380511 Keywords : cytokines * pharmaceutical proteins * plant-based production systems Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.598, year: 2011

  8. Phenolics and Plant Allelopathy

    Directory of Open Access Journals (Sweden)

    De-An Jiang

    2010-12-01

    Full Text Available Phenolic compounds arise from the shikimic and acetic acid (polyketide metabolic pathways in plants. They are but one category of the many secondary metabolites implicated in plant allelopathy. Phenolic allelochemicals have been observed in both natural and managed ecosystems, where they cause a number of ecological and economic problems, such as declines in crop yield due to soil sickness, regeneration failure of natural forests, and replanting problems in orchards. Phenolic allelochemical structures and modes of action are diverse and may offer potential lead compounds for the development of future herbicides or pesticides. This article reviews allelopathic effects, analysis methods, and allelopathic mechanisms underlying the activity of plant phenolic compounds. Additionally, the currently debated topic in plant allelopathy of whether catechin and 8-hydroxyquinoline play an important role in Centaurea maculata and Centaurea diffusa invasion success is discussed. Overall, the main purpose of this review is to highlight the allelopacthic potential of phenolic compounds to provide us with methods to solve various ecology problems, especially in regard to the sustainable development of agriculture, forestry, nature resources and environment conservation.

  9. Plant breeding and genetics

    Science.gov (United States)

    The ultimate goal of plant breeding is to develop improved crops. Improvements can be made in crop productivity, crop processing and marketing, and/or consumer quality. The process of developing an improved cultivar begins with intercrossing lines with high performance for the traits of interest, th...

  10. Plant monitor system

    International Nuclear Information System (INIS)

    Scarola, K.; Jamison, D.; Manazir, R.; Rescori, R.; Harmon, D.

    1991-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system which is nuclear qualified for rapid response to changes in plant parameters and a component control system which together provide a discrete monitoring and control capability at a panel in the control room. A separate data processing system, which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs and a large, overhead integrated process status overview board. The discrete indicator and alarm system and the data processing system receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the main machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof. (author)

  11. TAPCHAN Wave Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    1983-10-01

    The Tapered Channel Wave Power Plant (TAPCHAN) is based on a new method for wave energy conversion. The principle of operation can be explained by dividing the system into the following four sub-systems: Firstly, a collector which is designed to concentrate the water energy and optimize collection efficiency for a range of frequencies and directions. Secondly, the energy converter, in which the energy of the collected waves is transformed into potential energy in an on-shore water reservoir. This is the unique part of the power plant. It consists of a gradually narrowing channel with wall heights equal to the filling level of the reservoir (typical heights 3-7 m). The waves enter the wide end of the channel and as they propagate down the narrowing channel, the wave height is amplified until the wavecrests spill over the walls. Thirdly, a reservoir which provides a stable water supply for the turbines. Finally, the hydroelectric power plant, where well established techniques are used for the generation of electric power. The water turbine driving the electric generator is of a low head type, such as a Kaplan or a tubular turbine. It must be designed for salt water operation and should have good regulation capabilities. Power plants based on the principle described, are now offered on a commercial basis.

  12. Plant Modernization Programs

    International Nuclear Information System (INIS)

    O'Hara, John

    2004-01-01

    Most nuclear plants were designed and built from the 1960's through the 1990's. These plants employ predominantly analog instrumentation and control (I and C) technology, and their control rooms are made up of primarily hardwired controls (e.g., switches, knobs and handles) and displays (e.g., gauges, linear scales and indicator lights). Over the past several years, these plants have been modernized with digital I and C and computer-based human-system interfaces (HSIs) such as software-based process controls, touch-screen interfaces and large-screen, overview displays. As these computer based HIS technologies are integrated into control rooms based on conventional technology, hybrid control rooms are created. The paper summarizes lessons learned from the study of plant modernization programs over the past ten years so that they can be used to help improve the modification process. While the research focused on the impact of technology change on human performance, a number of organizational and programmatic issues were observed as well. Eleven lessons learned are presented

  13. Plants under continuous light

    NARCIS (Netherlands)

    Velez Ramirez, A.I.; Ieperen, van W.; Vreugdenhill, D.; Millenaar, F.F.

    2011-01-01

    Continuous light is an essential tool for understanding the plant circadian clock. Additionally, continuous light might increase greenhouse food production. However, using continuous light in research and practice has its challenges. For instance, most of the circadian clock-oriented experiments

  14. Nuclear plant scram reduction

    International Nuclear Information System (INIS)

    Wiegle, H.R.

    1986-01-01

    The Nuclear Utility Management and Human Resources Committee (NUMARC) is a confederation of all 55 utilities with nuclear plants either in operation or under construction. NUMARC was formed in April 1984 by senior nuclear executives with hundreds of man-years of plant experience to improve (plant) performance and resolve NRC concerns. NUMARC has adopted 10 commitments in the areas of management, training, staffing and performance. One of these commitments is to strive to reduce automatic trips to 3 per year per unit for calendar year 1985 for plants in commercial operation greater than 3 years (with greater than 25% capacity factor). This goal applies to any unplanned automatic protection system trips at any time when the reactor is critical. Each utility has committed to develop methods to thoroughly evaluate all unplanned automatic trips to identify the root causes and formulate plans to correct the root causes thus reducing future unplanned scrams. As part of this program, the Institute of Nuclear Power Operations (INPO) collects and evaluates information on automatic reactor trips. It publishes the results of these evaluations to aid the industry to identify root causes and corrective actions

  15. Italian steam power plants

    Energy Technology Data Exchange (ETDEWEB)

    von Rautenkranz, J

    1939-01-01

    A brief history of geothermal power production in Italy is presented. Boric acid has been produced on an industrial scale since 1818. The first electrical power was generated in 1904, and by 1939 the output of geothermal power plants had reached 500 GWh, with major expansion of facilities planned.

  16. Plants and Medicinal Chemistry

    Science.gov (United States)

    Bailey, D.

    1977-01-01

    This is the first of two articles showing how plants that have been used in folk medicine for many centuries are guiding scientists in the design and preparation of new and potent drugs. Opium and its chemical derivatives are examined at length in this article. (Author/MA)

  17. Whitebark pine planting guidelines

    Science.gov (United States)

    Ward McCaughey; Glenda L. Scott; Kay L. Izlar

    2009-01-01

    This article incorporates new information into previous whitebark pine guidelines for planting prescriptions. Earlier 2006 guidelines were developed based on review of general literature, research studies, field observations, and standard US Forest Service survival surveys of high-elevation whitebark pine plantations. A recent study of biotic and abiotic factors...

  18. Power plant at sea

    International Nuclear Information System (INIS)

    Roggen, M.

    2000-01-01

    Drilling platforms are rather inefficient when it comes to their own power supply. In view of ecotax and their environmental image, the offshore industry particularly the Norwegians is highly committed to changing this situation. An efficient power plant, specially designed for the offshore industry, might just prove to be the answer to their prayers

  19. Mechanisms in Plant Development

    Energy Technology Data Exchange (ETDEWEB)

    Hake, Sarah [USDA ARS Plant Gene Expression Center

    2013-08-21

    This meeting has been held every other year for the past twenty-two years and is the only regularly held meeting focused specifically on plant development. Topics covered included: patterning in developing tissues; short and long distance signaling; differentiation of cell types; the role of epigenetics in development; evolution; growth.

  20. Plant Biotech Lab Manual.

    Science.gov (United States)

    Tant, Carl

    This book provides laboratory experiments to enhance any food science/botany curriculum. Chapter 1, "Introduction," presents a survey of the techniques used in plant biotechnology laboratory procedures. Chapter 2, "Micronutrition," discusses media and nutritional requirements for tissue culture studies. Chapter 3, "Sterile Seeds," focuses on the…

  1. Radiosensitivity in plants

    International Nuclear Information System (INIS)

    Nauman, A.F.

    1979-01-01

    The report presents a compilation of available data on the sensitivity of plants to ionizing radiation, and provides basic information on methods of determining such sensitivities, or of estimating radiosensitivities by calcuation of the nuclear factors upon which they depend. The scope of the data presented here is necessarily limited to the most generally useful radiobiological end points and to the most commonly-used types of radiation. Many of the factors which influence radiosensitivity, particularly nuclear factors, will be discussed. Emphasis will be upon whole-plant studies done at Brookhaven National Laboratory by A.H. Sparrow and his associates, since these studies are the source of most of the available radiosensitivity data and of all the sensitivity predictions listed here. Data presented here include summaries of experimentally-determined radiosensitivities at various end points for both herbaceous and woody higher plants, and for a few species of ferns and lower plants. The algae and fungi have not been considered here due to space limitations

  2. Chromosome painting in plants.

    NARCIS (Netherlands)

    Schubert, I.; Fransz, P.F.; Fuchs, J.; Jong, de J.H.

    2001-01-01

    The current 'state-of-art' as to chromosome painting in plants is reviewed. We define different situations described as painting so far: i) Genomic in situ hybridisation (GISH) with total genomic DNA to distinguish alien chromosomes on the basis of divergent dispersed repeats, ii) 'Chromosomal in

  3. Nuclear Power Plant Technician

    Science.gov (United States)

    Randall, George A.

    1975-01-01

    The author recognizes a body of basic knowledge in nuclear power plant technoogy that can be taught in school programs, and lists the various courses, aiming to fill the anticipated need for nuclear-trained manpower--persons holding an associate degree in engineering technology. (Author/BP)

  4. Plant cell culture initiation

    NARCIS (Netherlands)

    Hall, R.D.

    2000-01-01

    The use of cultured plant cells in either organized or unorganized form has increased vey considerably in the last 10-15 yr. Many new technologies have been developed and applications in both fundamental and applied research have led to the development of some powerful tools for improving our

  5. Screening for Plant Features

    NARCIS (Netherlands)

    Heijden, van der G.W.A.M.; Polder, G.

    2015-01-01

    In this chapter, an overview of different plant features is given, from (sub)cellular to canopy level. A myriad of methods is available to measure these features using image analysis, and often, multiple methods can be used to measure the same feature. Several criteria are listed for choosing a

  6. The plant exocyst

    NARCIS (Netherlands)

    Zhang, Y.; Emons, A.M.C.; Ketelaar, T.

    2010-01-01

    exocyst is an octameric vesicle tethering complex that functions upstream of SNARE mediated exocytotic vesicle fusion with the plasma membrane. All proteins in the complex have been conserved during evolution, and genes that encode the exocyst subunits are present in the genomes of all plants

  7. Plants flex their skeletons

    DEFF Research Database (Denmark)

    Foster, Randy; Mattsson, Ole; Mundy, John

    2003-01-01

    Recent work on the fragile fiber mutants of Arabidopsis has identified microtubule-associated proteins that affect the orientation of cellulose microfibrils in cell walls, a major determinant of plant elongation growth. These same proteins are implicated in responses to gibberellin, provoking fresh...

  8. Quality maintenance Tropical Plants

    Directory of Open Access Journals (Sweden)

    Gláucia Moraes Dias

    2016-11-01

    Full Text Available The climatic characteristics of the country favor the cultivation of tropical flowers. The continued expansion of this market is due the beauty, exoticit nature and postharvest longevity of flower. However, little is known about the postharvest of tropical plants. Therefore, this paper provides information on harvest, handling and storage of cut tropical plantspostharvest, storage temperature, conditioning solution.

  9. Radiosensitivity in plants

    Energy Technology Data Exchange (ETDEWEB)

    Nauman, A F

    1979-01-01

    The report presents a compilation of available data on the sensitivity of plants to ionizing radiation, and provides basic information on methods of determining such sensitivities, or of estimating radiosensitivities by calcuation of the nuclear factors upon which they depend. The scope of the data presented here is necessarily limited to the most generally useful radiobiological end points and to the most commonly-used types of radiation. Many of the factors which influence radiosensitivity, particularly nuclear factors, will be discussed. Emphasis will be upon whole-plant studies done at Brookhaven National Laboratory by A.H. Sparrow and his associates, since these studies are the source of most of the available radiosensitivity data and of all the sensitivity predictions listed here. Data presented here include summaries of experimentally-determined radiosensitivities at various end points for both herbaceous and woody higher plants, and for a few species of ferns and lower plants. The algae and fungi have not been considered here due to space limitations.

  10. Peru, People and Plants.

    Science.gov (United States)

    Thompson, Dennis

    Designed for horticulture, horticulture therapy, and botany students at Edmonds Community College (Washington), this 6-hour module explores the pre-Columbian use of plant materials in Peru and its relationships to cultural practices in modern Peru. The first sections provide basic information about the module, such as its objectives, the concepts…

  11. Fertilization in Flowering Plants

    Indian Academy of Sciences (India)

    ... for the right pollen,the pistil imposes a tough competition amongst them, comparableto a swayamvara of Indian mythology, to select the bestavailable pollen. Flowering plants have evolved into a matriarchalsociety. The selection of the male partner is totally theprerogative of the mother (pistil); the boy (pollen grain) andthe ...

  12. T Plant hazards assessment

    International Nuclear Information System (INIS)

    Broz, R.E.

    1994-01-01

    This document establishes the technical basis in support of Emergency Planning activities for the T Plant on the Hanford Site. The document represents an acceptable interpretation of the implementing guidance document for DOE ORDER 5500.3A. Through this document, the technical basis for the development of facility specific Emergency Action Levels and the Emergency Planning Zone is demonstrated

  13. Steam power plant

    International Nuclear Information System (INIS)

    Campbell, J.W.E.

    1981-01-01

    This invention relates to power plant forced flow boilers operating with water letdown. The letdown water is arranged to deliver heat to partly expanded steam passing through a steam reheater connected between two stages of the prime mover. (U.K.)

  14. Garigliano nuclear power plant

    International Nuclear Information System (INIS)

    1976-03-01

    During the period under review, the Garigliano power station produced 1,028,77 million kWh with a utilization factor of 73,41% and an availability factor of 85,64%. The disparity between the utilization and availability factors was mainly due to a shutdown of about one and half months owing to lack of staff at the plant. The reasons for nonavailability (14.36%) break down as follows: nuclear reasons 11,49%; conventional reasons 2,81%; other reasons 0,06%. During the period under review, no fuel replacements took place. The plant functioned throughout with a single reactor reticulation pump and resulting maximum available capacity of 150 MWe gross. After the month of August, the plant was operated at levels slightly below the maximum available capacity in order to lengthen the fuel cycle. The total number of outages during the period under review was 11. Since the plant was brought into commercial operation, it has produced 9.226 million kWh

  15. Evolution of plant senescence

    Directory of Open Access Journals (Sweden)

    Young Mike

    2009-07-01

    Full Text Available Abstract Background Senescence is integral to the flowering plant life-cycle. Senescence-like processes occur also in non-angiosperm land plants, algae and photosynthetic prokaryotes. Increasing numbers of genes have been assigned functions in the regulation and execution of angiosperm senescence. At the same time there has been a large expansion in the number and taxonomic spread of plant sequences in the genome databases. The present paper uses these resources to make a study of the evolutionary origins of angiosperm senescence based on a survey of the distribution, across plant and microbial taxa, and expression of senescence-related genes. Results Phylogeny analyses were carried out on protein sequences corresponding to genes with demonstrated functions in angiosperm senescence. They include proteins involved in chlorophyll catabolism and its control, homeoprotein transcription factors, metabolite transporters, enzymes and regulators of carotenoid metabolism and of anthocyanin biosynthesis. Evolutionary timelines for the origins and functions of particular genes were inferred from the taxonomic distribution of sequences homologous to those of angiosperm senescence-related proteins. Turnover of the light energy transduction apparatus is the most ancient element in the senescence syndrome. By contrast, the association of phenylpropanoid metabolism with senescence, and integration of senescence with development and adaptation mediated by transcription factors, are relatively recent innovations of land plants. An extended range of senescence-related genes of Arabidopsis was profiled for coexpression patterns and developmental relationships and revealed a clear carotenoid metabolism grouping, coordinated expression of genes for anthocyanin and flavonoid enzymes and regulators and a cluster pattern of genes for chlorophyll catabolism consistent with functional and evolutionary features of the pathway. Conclusion The expression and phylogenetic

  16. Plant life management optimized utilization of existing nuclear power plants

    International Nuclear Information System (INIS)

    Watzinger, H.; Erve, M.

    1999-01-01

    For safe, reliable and economical nuclear power generation it is of central importance to understand, analyze and manage aging-related phenomena and to apply this information in the systematic utilization and as-necessary extension of the service life of components and systems. An operator's overall approach to aging and plant life management which also improves performance characteristics can help to optimize plant operating economy. In view of the deregulation of the power generation industry with its increased competition, nuclear power plants must today also increasingly provide for or maintain a high level of plant availability and low power generating costs. This is a difficult challenge even for the newest, most modern plants, and as plants age they can only remain competitive if a plant operator adopts a strategic approach which takes into account the various aging-related effects on a plant-wide basis. The significance of aging and plant life management for nuclear power plants becomes apparent when looking at their age: By the year 2000 roughly fifty of the world's 434 commercial nuclear power plants will have been in operation for thirty years or more. According to the International Atomic Energy Agency, as many as 110 plants will have reached the thirty-year service mark by the year 2005. In many countries human society does not push the construction of new nuclear power plants and presumably will not change mind within the next ten years. New construction licenses cannot be expected so that for economical and ecological reasons existing plants have to be operated unchallengeably. On the other hand the deregulation of the power production market is asking just now for analysis of plant life time to operate the plants at a high technical and economical level until new nuclear power plants can be licensed and constructed. (author)

  17. Negative sequence relay applied to generator 1 of the Laguna Verde nuclear power plant; Aplicacion de un relevador de secuencia negativa en el generador 1 de la central de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Diaz de la Serna P, Enrique [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    The rotor of a synchronous generator can be dangerously heated in a short time by stator current unbalance, therefore it must be protected with a specific relay. This article discusses the protection and the adjustments selected for Unit 1 of the Comision Federal de Electricidad Laguna Verde Nuclear Nuclear Power Station. [Espanol] El rotor de un generador sincrono puede calentarse peligrosamente en un tiempo corto debido a desbalance de corrientes en el estator, por lo que debe protegerse con un relevador especifico. En este articulo se describen la proteccion y los ajustes seleccionados para la unidad 1, de la central nucleoelectrica Laguna Verde de la Comision Federal de Electricidad.

  18. Nuclear power plant safety

    International Nuclear Information System (INIS)

    Otway, H.J.

    1974-01-01

    Action at the international level will assume greater importance as the number of nuclear power plants increases, especially in the more densely populated parts of the world. Predictions of growth made prior to October 1973 [9] indicated that, by 1980, 14% of the electricity would be supplied by nuclear plants and by the year 2000 this figure would be about 50%. This will make the topic of international co-operation and standards of even greater importance. The IAEA has long been active in providing assistance to Member States in the siting design and operation of nuclear reactors. These activities have been pursued through advisory missions, the publication of codes of practice, guide books, technical reports and in arranging meetings to promote information exchange. During the early development of nuclear power, there was no well-established body of experience which would allow formulation of internationally acceptable safety criteria, except in a few special cases. Hence, nuclear power plant safety and reliability matters often received an ad hoc approach which necessarily entailed a lack of consistency in the criteria used and in the levels of safety required. It is clear that the continuation of an ad hoc approach to safety will prove inadequate in the context of a world-wide nuclear power industry, and the international trade which this implies. As in several other fields, the establishment of internationally acceptable safety standards and appropriate guides for use by regulatory bodies, utilities, designers and constructors, is becoming a necessity. The IAEA is presently planning the development of a comprehensive set of basic requirements for nuclear power plant safety, and the associated reliability requirements, which would be internationally acceptable, and could serve as a standard frame of reference for nuclear plant safety and reliability analyses

  19. Photooxidative stress in plants

    International Nuclear Information System (INIS)

    Foyer, C.H.; Lelandais, M.; Kunert, K.J.

    1994-01-01

    The light-dependent generation of active oxygen species is termed photooxidative stress. This can occur in two ways: (1) the donation of energy or electrons directly to oxygen as a result of photosynthetic activity; (2) exposure of tissues to ultraviolet irradiation. The light-dependent destruction of catalase compounds the problem. Although generally detrimental to metabolism, superoxide and hydrogen peroxide may serve useful functions if rigorously controlled and compartmentalised. During photosynthesis the formation of active oxygen species is minimised by a number of complex and refined regulatory mechanisms. When produced, active oxygen species are eliminated rapidly by efficient antioxidative systems. The chloroplast is able to use the production and destruction of hydrogen peroxide to regulate the thermal dissipation of excess excitation energy. This is an intrinsic feature of the regulation of photosynthetic electron transport. Photoinhibition and photooxidation only usually occur when plants are exposed to stress. Active oxygen species are part of the alarm-signalling processes in plants. These serve to modify metabolism and gene expression so that the plant can respond to adverse environmental conditions, invading organisms and ultraviolet irradiation. The capacity of the antioxidative defense system is often increased at such times but if the response is not sufficient, radical production will exceed scavenging and ultimately lead to the disruption of metabolism. Oxidative damage arises in high light principally when the latter is in synergy with additional stress factors such as chilling temperatures or pollution. Environmental stress can modify the photooxidative processes in various ways ranging from direct involvement in light-induced free radical formation to the inhibition of metabolism that renders previously optimal light levels excessive. It is in just such situations that the capacity for the production of active oxygen species can exceed that

  20. Heating plant privatization stagnates

    International Nuclear Information System (INIS)

    Janoska, J.; Benka, M.; Sobinkovic, B.; Haluza, I.

    2005-01-01

    The state has been talking about privatization of 6 municipal heating plants since 2001. The tenders were to start last year. But nothing has happened and the future is uncertain. The city councils would prefer to receive, if not 100%, then at least a majority stake in the heating plants free of charge. But the Cabinet has decided to sell 51% to investors. The privatization agency - the National Property Fund (FNM) is preparing a proposal to increase the stake offered for sale to 67%. According to information provided by the FNM the sale will begin after Cabinet approval. The Fund intends to apply the same model to the sale of all the heating plants. Last year, a major German company Verbundnetz Gas declared its interest in purchasing large municipal heating plants in Slovakia. But it has been waiting for a response ever since. The French company - Dalkia, which has 10-years' experience of doing business in Slovakia, is interested in all the heating plants to be offered for sale. The Austrian company - Stefe is not new to the business either, it is interested mainly in the regions where it has already established itself - Central and Eastern Slovakia. Strategic investors expect financial groups to show interest too. The Penta Group has not hid its ambitions - it has already privatised a company which represents the key to the future development of heat management in Bratislava - Paroplynovy cyklus. Whereas Penta is not new to the heat production business another financial group - Slavia Capital is still surveying the sector. Should it not succeed, it plans several projects that would allow it to take a stake in the sector