WorldWideScience

Sample records for plant reinforced concrete

  1. Report on aging of nuclear power plant reinforced concrete structures

    Energy Technology Data Exchange (ETDEWEB)

    Naus, D.J.; Oland, C.B. [Oak Ridge National Lab., TN (United States); Ellingwood, B.R. [Johns Hopkins Univ., Baltimore, MD (United States). Dept. of Civil Engineering

    1996-03-01

    The Structural Aging Program provides the US Nuclear Regulatory Commission with potential structural safety issues and acceptance criteria for use in continued service assessments of nuclear power plant safety-related concrete structures. The program was organized under four task areas: Program Management, Materials Property Data Base, Structural Component Assessment/Repair Technology, and Quantitative Methodology for Continued Service Determinations. Under these tasks, over 90 papers and reports were prepared addressing pertinent aspects associated with aging management of nuclear power plant reinforced concrete structures. Contained in this report is a summary of program results in the form of information related to longevity of nuclear power plant reinforced concrete structures, a Structural Materials Information Center presenting data and information on the time variation of concrete materials under the influence of environmental stressors and aging factors, in-service inspection and condition assessments techniques, repair materials and methods, evaluation of nuclear power plant reinforced concrete structures, and a reliability-based methodology for current and future condition assessments. Recommendations for future activities are also provided. 308 refs., 61 figs., 50 tabs.

  2. Green Plant Extract as a passivationpromoting Inhibitor for Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Abdulrahman A. S.

    2011-08-01

    Full Text Available The present corrosion inhibitors in market for the protection of steel reinforcement in concrete exposed to chloride attack are toxic to the environment and compromises sustainability drives. There is the needs to develop inhibitor that are eco-friendly and sustainable. In this work the ability of hydrophobic green plant extracts inhibitor (Bambusa arundinacea to repassivates the chloride induced corrosion of steel was studied. Its efficacy and effectiveness was also compared with calcium nitrite inhibitor. Concrete mix was designed to 30MPa with 0.45 W/C ratios and 1.5% weight of cement content of chloride was added to initiate corrosion.Inhibitors additions were 2%. Electrochemical impedance spectroscopy, linear polarization resistance and Field emission spectroscopy (FESEM were used to monitor corrosion behavior of steel at 180 days exposure period. Corrosion rate of the inhibitors studied showed that Bambusa Arundinacea is superior as compared to calcium nitrite as results of its high concrete resistivity, chloride binding property and polarization resistance. Bambusa Arundinacea may be considered a better substitute for nitrite based corrosion inhibiting admixtures for durable concrete structures due its versatility.

  3. Boiling water reactor in a prestressed reinforced concrete vessel for an atomic central heating-and-power plant

    Energy Technology Data Exchange (ETDEWEB)

    Tokarev, Yu.I.; Sokolov, I.N.; Skvortsov, S.A.; Sidorov, A.M.; Krauze, L.V.

    1978-04-01

    The possibility of using a boiling water reactor in a prestressed reinforced concrete vessel for an atomic central heating-and-power plant (CHPP) was considered, with design features of the reactor intended for a two-purpose plant. A prestressed reinforced concrete vessel and integral arrangement of the primary circuit ensured reliability of the atomic CHPP using various CHPP flowsheets.

  4. Primer on Durability of Nuclear Power Plant Reinforced Concrete Structures - A Review of Pertinent Factors

    Energy Technology Data Exchange (ETDEWEB)

    Naus, Dan J [ORNL

    2007-02-01

    The objective of this study was to provide a primer on the environmental effects that can affect the durability of nuclear power plant concrete structures. As concrete ages, changes in its properties will occur as a result of continuing microstructural changes (i.e., slow hydration, crystallization of amorphous constituents, and reactions between cement paste and aggregates), as well as environmental influences. These changes do not have to be detrimental to the point that concrete will not be able to meet its performance requirements. Concrete, however, can suffer undesirable changes with time because of improper specifications, a violation of specifications, or adverse performance of its cement paste matrix or aggregate constituents under either physical or chemical attack. Contained in this report is a discussion on concrete durability and the relationship between durability and performance, a review of the historical perspective related to concrete and longevity, a description of the basic materials that comprise reinforced concrete, and information on the environmental factors that can affect the performance of nuclear power plant concrete structures. Commentary is provided on the importance of an aging management program.

  5. Continuous Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Hoang, Cao Linh; Nielsen, Mogens Peter

    1996-01-01

    This report deals with stress and stiffness estimates of continuous reinforced concrete beams with different stiffnesses for negative and positive moments e.g. corresponding to different reinforcement areas in top and bottom. Such conditions are often met in practice.The moment distribution...

  6. Post-cracking behavior of blocks, prisms, and small concrete walls reinforced with plant fiber

    Directory of Open Access Journals (Sweden)

    I. I. Soto

    Full Text Available Structural masonry using concrete blocks promotes the rationalization of construction projects, lowering the final cost of a building through the elimination of forms and the reduction of the consumption of reinforcement bars. Moreover, production of a block containing a combination of concrete and vegetable fiber sisal results in a unit with properties such as mechanical strength, stiffness, flexibility, ability to absorb energy, and post-cracking behavior that are comparable to those of a block produced with plain concrete. Herein are reported the results of a study on the post-cracking behavior of blocks, prisms, and small walls reinforced with sisal fibers (lengths of 20 mm and 40 mm added at volume fractions of 0.5% and 1%. Tests were performed to characterize the fibers and blocks and to determine the compressive strength of the units, prisms, and small walls. The deformation modulus of the elements was calculated and the stress-strain curves were plotted to gain a better understanding of the values obtained. The compression test results for the small walls reinforced with fibers were similar to those of the reference walls and better than the blocks and prisms with added fibers, which had resistances lower than those of the corresponding conventional materials. All elements prepared with the addition of sisal exhibited an increase in the deformation capacity (conferred by the fibers, which was observed in the stress-strain curves. The failure mode of the reference elements was characterized by an abrupt fracture, whereas the reinforced elements underwent ductile breakage. This result was because of the presence of the fibers, which remained attached to the faces of the cracks via adhesion to the cement matrix, thus preventing loss of continuity in the material. Therefore, the cement/plant fiber composites are advantageous in terms of their ductility and ability to resist further damage after cracking.

  7. Continuous Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Hoang, Cao Linh; Nielsen, Mogens Peter

    1996-01-01

    This report deals with stress and stiffness estimates of continuous reinforced concrete beams with different stiffnesses for negative and positive moments e.g. corresponding to different reinforcement areas in top and bottom. Such conditions are often met in practice.The moment distribution...... at the limit state of serviceability is in some simple cases determined by setting up the statical and the compatibility conditions.With these moment distributions, the maximum deflection and the reinforcement stresses at the span middle and at a support are calculated.The results are compared with results...

  8. STRUCTURAL PERFORMANCE OF DEGRADED REINFORCED CONCRETE MEMBERS.

    Energy Technology Data Exchange (ETDEWEB)

    Braverman, J.I.; Miller, C.A.; Ellingwood, B.R.; Naus, D.J.; Hofmayer, C.H.; Bezler, P.; Chang, T.Y.

    2001-03-22

    This paper describes the results of a study to evaluate, in probabilistic terms, the effects of age-related degradation on the structural performance of reinforced concrete members at nuclear power plants. The paper focuses on degradation of reinforced concrete flexural members and shear walls due to the loss of steel reinforcing area and loss of concrete area (cracking/spalling). Loss of steel area is typically caused by corrosion while cracking and spalling can be caused by corrosion of reinforcing steel, freeze-thaw, or aggressive chemical attack. Structural performance in the presence of uncertainties is depicted by a fragility (or conditional probability of failure). The effects of degradation on the fragility of reinforced concrete members are calculated to assess the potential significance of various levels of degradation. The fragility modeling procedures applied to degraded concrete members can be used to assess the effects of degradation on plant risk and can lead to the development of probability-based degradation acceptance limits.

  9. Corrosion Inhibitors for Reinforced Concrete

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    Steel corrosion in reinforced concrete structures has been a major problem across the U.S. Steel-reinforced concrete structures are continually subject to attack by corrosion brought on by naturally occurring environmental conditions. FerroGard, a corrosion inhibitor, developed by Sika Corporation, penetrates hardened concrete to dramatically reduce corrosion by 65% and extend the structure's service life.

  10. Cellular fiber–reinforced concrete

    OpenAIRE

    Isachenko S.; Kodzoev M.

    2016-01-01

    Methods disperse reinforcement of concrete matrix using polypropylene, glass, basalt and metal fibers allows to make the construction of complex configuration, solve the problem of frost products. Dispersed reinforcement reduces the overall weight of the structures. The fiber replaces the secondary reinforcement, reducing the volume of use of structural steel reinforcement. Cellular Fiber concretes are characterized by high-performance properties, especially increased bending strength and...

  11. Modelling reinforcement corrosion in concrete

    DEFF Research Database (Denmark)

    Michel, Alexander; Geiker, Mette Rica; Stang, Henrik

    2012-01-01

    A physio-chemical model for the simulation of reinforcement corrosion in concrete struc-tures was developed. The model allows for simulation of initiation and subsequent propaga-tion of reinforcement corrosion. Corrosion is assumed to be initiated once a defined critical chloride threshold...... is reached causing the formation of anodic and cathodic regions along the reinforcement. Critical chloride thresholds, randomly distributed along the reinforcement sur-face, link the initiation and propagation phase of reinforcement corrosion. To demonstrate the potential use of the developed model......, a numerical example is pre-sented, that illustrates the formation of corrosion cells as well as propagation of corrosion in a reinforced concrete structure....

  12. Qualitative and Quantitative Seismic Evaluation of Reinforced Concrete Structures in Petrochemical Plant

    Directory of Open Access Journals (Sweden)

    Fariborz Nateghi-A.

    2010-12-01

    Full Text Available In this paper the seismic evaluation of reinforced concrete structures in petrochemical facilities under sever conditions such as high pressure, high temperature and corrosive environment is studied. These structures were designed and constructed during 1976-78. The evaluation procedure is basically performed in two phases namely; a qualitative and b quantitative methods. In the qualitative evaluation, all possible documentations including drawings, specifications, structural calculations, new additions and test results were studied. Collected data then was summarized in an evaluation checklist. When the needed requirements did not meet the specified entries, more detailed and quantitative analysis were performed and utilized in this study. Quantitative and numerical study was performed using finite element modeling under sever loading combinations. Based on the results of this evaluation, some important RC structures in this plant were highly vulnerable to seismic forces which required immediate attention. The methodology used and results obtained can be generalized and adapted for similar facilities. This paper will present details, procedure and conclusions obtained.

  13. Optimization of reinforced concrete slabs

    Science.gov (United States)

    Ferritto, J. M.

    1979-01-01

    Reinforced concrete cells composed of concrete slabs and used to limit the effects of accidental explosions during hazardous explosives operations are analyzed. An automated design procedure which considers the dynamic nonlinear behavior of the reinforced concrete of arbitrary geometrical and structural configuration subjected to dynamic pressure loading is discussed. The optimum design of the slab is examined using an interior penalty function. The optimization procedure is presented and the results are discussed and compared with finite element analysis.

  14. Optimization of reinforced concrete slabs

    Science.gov (United States)

    Ferritto, J. M.

    1979-01-01

    Reinforced concrete cells composed of concrete slabs and used to limit the effects of accidental explosions during hazardous explosives operations are analyzed. An automated design procedure which considers the dynamic nonlinear behavior of the reinforced concrete of arbitrary geometrical and structural configuration subjected to dynamic pressure loading is discussed. The optimum design of the slab is examined using an interior penalty function. The optimization procedure is presented and the results are discussed and compared with finite element analysis.

  15. Topology optimization of reinforced concrete structures

    DEFF Research Database (Denmark)

    Amir, Oded

    Recent advances regarding topology optimization procedures of reinforced concrete structures are presented. We discuss several approaches to the challenging problem of optimizing the distribution of concrete and steel reinforcement. In particular, the consideration of complex nonlinear constitutive...

  16. Impact of structural aging on seismic risk assessment of reinforced concrete structures in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Ellingwood, B.; Song, J. [Johns Hopkins Univ., Baltimore, MD (United States). Dept. of Civil Engineering

    1996-03-01

    The Structural Aging Program is addressing the potential for degradation of concrete structural components and systems in nuclear power plants over time due to aging and aggressive environmental stressors. Structures are passive under normal operating conditions but play a key role in mitigating design-basis events, particularly those arising from external challenges such as earthquakes, extreme winds, fires and floods. Structures are plant-specific and unique, often are difficult to inspect, and are virtually impossible to replace. The importance of structural failures in accident mitigation is amplified because such failures may lead to common-cause failures of other components. Structural condition assessment and service life prediction must focus on a few critical components and systems within the plant. Components and systems that are dominant contributors to risk and that require particular attention can be identified through the mathematical formalism of a probabilistic risk assessment, or PRA. To illustrate, the role of structural degradation due to aging on plant risk is examined through the framework of a Level 1 seismic PRA of a nuclear power plant. Plausible mechanisms of structural degradation are found to increase the core damage probability by approximately a factor of two.

  17. Modelling localised fracture of reinforced concrete structures

    OpenAIRE

    Liao, F; Huang, Z.

    2015-01-01

    This paper presents a robust finite element procedure for simulating the localised fracture of reinforced concrete members. In this new model the concrete member is modelled as an assembly of plain concrete, reinforcing steel bar and bond-link elements. The 4-node quadrilateral elements are used for 2D modelling of plain concrete elements, in which the extended finite element method is adopted to simulate the formation and growth of individual cracks. The reinforcing steel bars are modelled b...

  18. Mechanical characterization of fiber reinforced Polymer Concrete

    Directory of Open Access Journals (Sweden)

    João Marciano Laredo dos Reis

    2005-09-01

    Full Text Available A comparative study between epoxy Polymer Concrete plain, reinforced with carbon and glass fibers and commercial concrete mixes was made. The fibers are 6 mm long and the fiber content was 2% and 1%, respectively, in mass. Compressive tests were performed at room temperature and load vs. displacement curves were plotted up to failure. The carbon and glass fibers reinforcement were randomly dispersed into the matrix of polymer concrete. An increase in compressive properties was observed as function of reinforcement. The comparison also showed that Polymer Concrete, plain and reinforced, has a better performance than regular market concrete, suggesting that PC is a reliable alternative for construction industry.

  19. Corrosion of reinforcement bars in steel ibre reinforced concrete structures

    DEFF Research Database (Denmark)

    Solgaard, Anders Ole Stubbe

    Steel fibres have been known as an alternative to traditional reinforcement bars for special applications of structural concrete for decades and the use of steel fibre reinforced concrete (SFRC) has gradually increased in recent years. Steel fibres lead to reduced crack widths in concrete formed......, among other reasons, due to shrinkage and/or mechanical loading. Steel fibres are nowadays also used in combination with traditional reinforcement for structural concrete, where the role of the fibres is to minimize the crack widths whereas the traditional reinforcement bars are used for structural....... The aim of the work presented in this Ph.D. thesis was to quantify the influence of steel fibres on corrosion of traditional reinforcement bars embedded in uncracked concrete as well as cracked concrete. Focus of the work was set on the impact of steel fibres on corrosion propagation in uncracked concrete...

  20. Behavior of reinforced concrete beams reinforced with GFRP bars

    Directory of Open Access Journals (Sweden)

    D. H. Tavares

    Full Text Available The use of fiber reinforced polymer (FRP bars is one of the alternatives presented in recent studies to prevent the drawbacks related to the steel reinforcement in specific reinforced concrete members. In this work, six reinforced concrete beams were submitted to four point bending tests. One beam was reinforced with CA-50 steel bars and five with glass fiber reinforced polymer (GFRP bars. The tests were carried out in the Department of Structural Engineering in São Carlos Engineering School, São Paulo University. The objective of the test program was to compare strength, reinforcement deformation, displacement, and some anchorage aspects between the GFRP-reinforced concrete beams and the steel-reinforced concrete beam. The results show that, even though four GFRP-reinforced concrete beams were designed with the same internal tension force as that with steel reinforcement, their capacity was lower than that of the steel-reinforced beam. The results also show that similar flexural capacity can be achieved for the steel- and for the GFRP-reinforced concrete beams by controlling the stiffness (reinforcement modulus of elasticity multiplied by the bar cross-sectional area - EA and the tension force of the GFRP bars.

  1. Degradation of Waterfront Reinforced Concrete Structures

    African Journals Online (AJOL)

    Key words: Degradation, reinforced concrete, Dar es Salaam port. Abstract—One of the .... Plate 2. Typical cracks on concrete piers found on berth. 4 through 8. Plate 3. Exposed .... Rubaratuka, I. A. and Mulungu, D., 1999: Defects in reinforced ...

  2. Simulation analysis of impact tests of steel plate reinforced concrete and reinforced concrete slabs against aircraft impact and its validation with experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Sadiq, Muhammad, E-mail: muhammad.sadiq@pnra.org [Center for Nuclear Safety (CNS), Pakistan Nuclear Regulatory Authority (PNRA), PO Box 1912, Islamabad (Pakistan); Xiu Yun, Zhu, E-mail: lyzhuxiuyun@163.com [Nuclear and Radiation Safety Center (NSC), Ministry of Environmental Protection (MEP), Beijing (China); Rong, Pan, E-mail: panrong@chinansc.cn [Nuclear and Radiation Safety Center (NSC), Ministry of Environmental Protection (MEP), Beijing (China)

    2014-07-01

    Highlights: • Simulation analysis is carried out with two constitutive concrete models. • Winfrith model can better simulate nonlinear response of concrete than CSCM model. • Performance of steel plate concrete is better than reinforced concrete. • Thickness of safety related structures can be reduced by adopting steel plates. • Analysis results, mainly concrete material models should be validated. - Abstract: The steel plate reinforced concrete and reinforced concrete structures are used in nuclear power plants for protection against impact of an aircraft. In order to compare the impact resistance performance of steel plate reinforced concrete and reinforced concrete slabs panels, simulation analysis of 1/7.5 scale model impact tests is carried out by using finite element code ANSYS/LS-DYNA. The damage modes of all finite element models, velocity time history curves of the aircraft engine and damage to aircraft model are compared with the impact test results of steel plate reinforced concrete and reinforced concrete slab panels. The results indicate that finite element simulation results correlate well with the experimental results especially for constitutive winfrith concrete model. Also, the impact resistance performance of steel plate reinforced concrete slab panels is better than reinforced concrete slab panels, particularly the rear face steel plate is very effective in preventing the perforation and scabbing of concrete than conventional reinforced concrete structures. In this way, the thickness of steel plate reinforced concrete structures can be reduced in important structures like nuclear power plants against impact of aircraft. It also demonstrates the methodology to validate the analysis procedure with experimental and analytical studies. It may be effectively employed to predict the precise response of safety related structures against aircraft impact.

  3. Computation of reinforcement for solid concrete

    NARCIS (Netherlands)

    Hoogenboom, P.C.J.; De Boer, A.

    2008-01-01

    Reinforcement in a concrete structure is often determined based on linear elastic stresses. This paper considers computation of the required reinforcement when these stresses have been determined by the finite element method with volume elements. Included are both tension reinforcement and compressi

  4. Fatigue Performance of Fiber Reinforced Concrete

    DEFF Research Database (Denmark)

    Jun, Zhang; Stang, Henrik

    1996-01-01

    The objective of the present study is to obtain basic data of fibre reinforced concrete under fatigue load and to set up a theoretical model based on micromechanics. In this study, the bridging stress in fiber reinforced concrete under cyclic tensile load was investigted in details. The damage...... mechanism of the interface between fiber and matrix was proposed and a rational model given. Finally, the response of a steel fiber reinforced concrete beam under fatigue loading was predicted based on this model and compared with experimental results....

  5. Applications and Properties of Fibre Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Amit Rai1 ,

    2014-05-01

    Full Text Available In conventional concrete, micro-cracks develop before structure is loaded because of drying shrinkage and other causes of volume change. When the structure is loaded, the micro cracks open up and propagate because of development of such micro-cracks, results in inelastic deformation in concrete. Fibre reinforced concrete (FRC is cementing concrete reinforced mixture with more or less randomly distributed small fibres. In the FRC, a numbers of small fibres are dispersed and distributed randomly in the concrete at the time of mixing, and thus improve concrete properties in all directions. The fibers help to transfer load to the internal micro cracks. FRC is cement based composite material that has been developed in recent years. It has been successfully used in construction with its excellent flexural-tensile strength, resistance to spitting, impact resistance and excellent permeability and frost resistance. It is an effective way to increase toughness, shock resistance and resistance to plastic shrinkage cracking of the mortar. These fibers have many benefits. Steel fibers can improve the structural strength to reduce in the heavy steel reinforcement requirement. Freeze thaw resistance of the concrete is improved. Durability of the concrete is improved to reduce in the crack widths. Polypropylene and Nylon fibers are used to improve the impact resistance. Many developments have been made in the fiber reinforced concrete.

  6. Durability of cracked fibre reinforced concrete structures

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place

    1998-01-01

    Durability studies are carried out at BKM as part of the research project "Design Methods for Fibre Reinforced Concrete" (FRC) involving BKM, The Concrete Research Center at DTI, Building Technology at Aalborg University, Rambøll, 4K-Beton and Rasmussen & Schiøtz. Concrete beams with or without...... structure are made on specimens drilled or sawed from beams after unloading (mechanical load). The pore structure of the concretes will be studied by microscopy, sorption and suction curves. The test programme involves three different concrete qualities (water-cement ratios). Both steel fibres (ZP...

  7. Design Methods for Fibre Reinforced Concrete

    DEFF Research Database (Denmark)

    Stang, Henrik

    1996-01-01

    The present paper describes the outline of a research project on Fibre Reinforced Concrete (FRC) currently being carried out in Denmark under the supervision of Danish Council of Technology, Danish Technical Research Council and Danish Natural Science Research Counsil....

  8. Ductility Performance of Hybrid Fibre Reinforced Concrete

    OpenAIRE

    S. Eswari; P.N. Raghunath; Suguna, K

    2008-01-01

    This study presents a study on the ductility performance of hybrid fibre reinforced concrete. The influence of fibre content on the ductility performance of hybrid fibre reinforced concrete specimens having different fibre volume fractions was investigated. The parameters of investigation included modulus of rupture, ultimate load, service load, ultimate and service load deflection, crack width, energy ductility and deflection ductility. A total of 27 specimens, 100×100×500 mm, were tested to...

  9. Shaking Table Tests of Reinforced Concrete Frames

    DEFF Research Database (Denmark)

    Skjærbæk, P. S.; Kirkegaard, Poul Henning; Nielsen, Søren R.K.

    -varying systems and to verify various methods for damage assessment of reinforced concrete structures from soft motion measurements. In this study the maximum softening concept will be evaluated. In the paper the assessment obtained by this method is compared to visual damage assessment. The structures considered...... vector ARMA model is suitable for modal identification of degrading reinforced concrete structures and the maximum softening damage index calculated from the obtained identification provides a valuable tool for assessment of the damage state of the structure....

  10. Self-compacting fibre-reinforced concrete

    NARCIS (Netherlands)

    Grunewald, S.; Walraven, J.C.

    2001-01-01

    The project 'self-compacting fibre-reinforced concrete (SCFRC)' is part of the Dutch STW/PPM program - 'cement-bonded materials' - DCT.4010. Subproject III to which the project ,SCFRC' belongs deals with the development of new high performance concretes. The project 'SCFRC' aims at investigating the

  11. Strength of Cracked Reinforced Concrete Disks

    DEFF Research Database (Denmark)

    Hoang, Cao Linh; Nielsen, Mogens Peter

    1999-01-01

    The paper deals with models, based on the theory of plasticity, to be used in strength assessments of reinforced concrete disks suffering from different kinds of cracking. Based on the assumption that the sliding strength of concrete is reduced in sections where cracks are located, solutions...

  12. Influence of Additives on Reinforced Concrete Durability

    OpenAIRE

    2014-01-01

    The article presents the results of the research on carbonation and chloride induced corrosion mechanisms in reinforced concrete structures, based on three commercially available concrete admixtures: Xypex Admix C-1000, Penetron Admix and Elkem Microsilica. Carbonation takes place due to carbon dioxide diffusion, which in the required amount is present in the air. Chlorides penetrate concrete in case of the use of deicing salt or structure exploitation in marine atmosphere. Based on the imple...

  13. Modelling the Loss of Steel-Concrete Bonds in Corroded Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    2007-01-01

    The existing stochastic models for deterioration of reinforced concrete structures is extended by adding modelling of "loss of bond" due to corrosion between the reinforcement bars and the surrounding concrete.......The existing stochastic models for deterioration of reinforced concrete structures is extended by adding modelling of "loss of bond" due to corrosion between the reinforcement bars and the surrounding concrete....

  14. Limit analysis of solid reinforced concrete structures

    DEFF Research Database (Denmark)

    Larsen, Kasper Paaske

    2009-01-01

    element for lower bound analysis of reinforced concrete structures is presented. The method defines the stress state at a point within the solid as a combination of concrete- and reinforcement stresses and yield criterions are applied to the stress components separately. This method allows for orthotropic......Recent studies have shown that Semidefinite Programming (SDP) can be used effectively for limit analysis of isotropic cohesive-frictional continuums using the classical Mohr-Coulomb yield criterion. In this paper we expand on this previous research by adding reinforcement to the model and a solid...... reinforcement and it is therefore possible to analyze structures with complex reinforcement layouts. Tests are conducted to validate the method against well-known analytical solutions....

  15. Determining safety criteria for reinforced concrete structures of power plants taking the example of a nuclear power plant with RBMK

    Directory of Open Access Journals (Sweden)

    Nikolayev Valery

    2016-01-01

    Full Text Available The paper shows how safety criteria of nuclear power plants with reactor RBMK can be defined based on analytical, numerical and mixed calculation methods using data about strength characteristics of materials with the course of time.

  16. Modelling Tension Stiffening in Reinforced Concrete Structures

    DEFF Research Database (Denmark)

    Christiansen, Morten Bo; Nielsen, Mogens Peter

    1997-01-01

    flexure.In the first model, the yield zone model, it is assumed that the mean crack distance is a descending function of the reinforcement stress in a crack. Furthermore it is assumed that in certain zones between the cracks the concrete is carrying its full effective tensile strength, i.e. the concrete...... with deformations in reinforced concrete disks subjected to pure shear.A physical model for the shear stress-shear strain behaviour of disks, including tension stiffening, is proposed.In the disk model it is assumed that the tensile principal stress in the concrete decreases linearly from the initiation of cracking...... until a certain load level. At any load level the model can predict the shear strains of the disk and the inclination of the crack system. When regarding tension stiffening this latter parameter will be a function of the load level.The model is compared with experimental data, and in the light...

  17. FOAM CONCRETE REINFORCEMENT BY BASALT FIBRES

    Directory of Open Access Journals (Sweden)

    Zhukov Aleksey Dmitrievich

    2012-10-01

    Full Text Available The authors demonstrate that the foam concrete performance can be improved by dispersed reinforcement, including methods that involve basalt fibres. They address the results of the foam concrete modeling technology and assess the importance of technology-related parameters. Reinforcement efficiency criteria are also provided in the article. Dispersed reinforcement improves the plasticity of the concrete mix and reduces the settlement crack formation rate. Conventional reinforcement that involves metal laths and rods demonstrates its limited application in the production of concrete used for thermal insulation and structural purposes. Dispersed reinforcement is preferable. This technology contemplates the infusion of fibres into porous mixes. Metal, polymeric, basalt and glass fibres are used as reinforcing components. It has been identified that products reinforced by polypropylene fibres demonstrate substantial abradability and deformability rates even under the influence of minor tensile stresses due to the low adhesion strength of polypropylene in the cement matrix. The objective of the research was to develop the type of polypropylene of D500 grade that would demonstrate the operating properties similar to those of Hebel and Ytong polypropylenes. Dispersed reinforcement was performed by the basalt fibre. This project contemplates an autoclave-free technology to optimize the consumption of electricity. Dispersed reinforcement is aimed at the reduction of the block settlement in the course of hardening at early stages of their operation, the improvement of their strength and other operating properties. Reduction in the humidity rate of the mix is based on the plasticizing properties of fibres, as well as the application of the dry mineralization method. Selection of optimal parameters of the process-related technology was performed with the help of G-BAT-2011 Software, developed at Moscow State University of Civil Engineering. The authors also

  18. Behavior of Partially Restrained Reinforced Concrete Slabs.

    Science.gov (United States)

    1986-09-01

    Takehira, Derecho , and Iqbal [34] followed a similar approach to arrive at recommended design criteria for 1 the Naval Facilities Engineering Command...Datta, T. K., "Ultimate Strength of Reinforced Concrete Slab-Beam Systems: A New Approach," r Indian Concrete Journal, Bombay, India , Vol. 47, 1973, pp...Journal of Solids and Structures, Vol. 1, 1965, pp. 97-111. 34. Takehira, T., Derecho , A.T., and Iqbal, M., "Design Criteria for Deflection Capacity

  19. Influence of Additives on Reinforced Concrete Durability

    Directory of Open Access Journals (Sweden)

    Neverkovica Darja

    2014-12-01

    Full Text Available The article presents the results of the research on carbonation and chloride induced corrosion mechanisms in reinforced concrete structures, based on three commercially available concrete admixtures: Xypex Admix C-1000, Penetron Admix and Elkem Microsilica. Carbonation takes place due to carbon dioxide diffusion, which in the required amount is present in the air. Chlorides penetrate concrete in case of the use of deicing salt or structure exploitation in marine atmosphere. Based on the implemented research, Elkem Microsilica is the recommended additive for the use in aggressive environmental conditions. Use of Xypex Admix C-1000 and Penetron Admix have only average resistance to the aggressive environmental impact.

  20. Frost resistance of fibre reinforced concrete structures

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place

    1999-01-01

    Frost resistance of fibre reinforced concrete with 2.5-4.2% air and 6-9% air (% by volume in fresh concrete) casted in the laboratory and in-situ is compared. Steel fibres with hooked ends (ZP, length 30 mm) and polypropylene fibres (PP, CS, length 12 mm) are applied. It is shown that· addition...... of 0.4-1% by volume of fibres cannot replace air entrainment in order to secure a frost resistant concrete; the minimum amount of air needed to make the concrete frost resistant is not changed when adding fibres· the amount of air entrainment must be increased when fibres are added to establish...... the same amount of air pores as in the corresponding concrete without fibres...

  1. Ultra thin continuously reinforced concrete pavement research in south Africa

    CSIR Research Space (South Africa)

    Perrie, BD

    2007-08-01

    Full Text Available Ultra thin continuously reinforced concrete pavements (UTCRCP), in literature also referred to as Ultra Thin Reinforced High Performance Concrete (UTHRHPC), have been used in Europe successfully as a rehabilitation measure on steel bridge decks...

  2. Fracture Toughness of Fiber Reinforced Concrete.

    Science.gov (United States)

    1983-06-01

    14, 1979, pp. 443-449. 5 Mindess , S., Lawrence, F. V., and Kesler, C. E., "The J-Integral as a Fracture Criterion for Fiber Reinforced Concrete...34 Cement and Con- crete Research, Vol. 7, 1977 , pp. 731-742. 6 Velazco, G., Visalvanich, K., and Shah, S. P., "Fracture Behavior and Analysis of Fiber

  3. Rotational Capacity of Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Ulfkjær, J. P.; Henriksen, M. S.; Brincker, Rune

    1995-01-01

    The European Structural Integrity Society-Technical Committee 9, has initiated a Round Robin on 'Scale Effects and Transitional Failure Phenomena of Reinforced Concrete Beams in Flexure'. In Denmark, Aalborg University is participating. The programme for Aalborg University involves an experimental...

  4. Corrosion and Cracking of Reinforced Concrete

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    Modelling of the deterioration of reinforced concrete has in recent years changed from being a deterministic modelling based on experience to be stochastic modelling based on sound and consistent physical, chemical and mechanical principles. In this paper is presented a brief review of modern mod...... for time to initial corrosion, time to initial cracking, and time to a given crack width may be obtained....

  5. Highly Deformable Energy-Dissipating Reinforced Concrete Elements in Seismic Design of Reinforced Concrete Structures

    Directory of Open Access Journals (Sweden)

    Momoh Emmanuel Owoichoechi

    2017-06-01

    Full Text Available Incorporating scrap tyre rubber particles as partial replacement for aggregates has been found to produce concrete with improved ductility, deformability and damping which are desired characteristics of a viable material for enhancing structural response to earthquake vibrations. An analytical study using Drain-2dX was carried out to investigate the response of 4-storey, 3-bay reinforced concrete frames on innovative rubberised concrete deformable foundation models to simulated earthquake scaled to 5 different peak ground accelerations. Stress-strain properties of 3-layers aramid fibre-reinforced polymer (FRP-confinement for concrete incorporating waste rubber from scrap vehicle tyres were used to model the elements of this foundation models. With a partial decoupling of the superstructure from the direct earthquake force, the models showed up to 70% reduction in base shear, an improved overall q-factor of 7.1, and an estimated frame acceleration of 0.11g for an earthquake peak ground acceleration of 0.44g. This implies that a non-seismically designed reinforced concrete frame on the proposed rubberised concrete deformable foundation system would provide a simple, affordable and equally efficient alternative to the conventional and usually expensive earthquake resistant concrete frames. A supplementary Arrest System (SAS was proposed to anchor the frame from the resulting soft storey at the rubberised concrete foundation. A further research is recommended for the design of concrete hinges with rubberised concrete as used in the model with the most impressive response.

  6. Shear Behavior of Concrete Beams Reinforced with GFRP Shear Reinforcement

    OpenAIRE

    Heecheul Kim; Min Sook Kim; Myung Joon Ko; Young Hak Lee

    2015-01-01

    This paper presents the shear capacities of concrete beams reinforced with glass fiber reinforced polymer (GFRP) plates as shear reinforcement. To examine the shear performance, we manufactured and tested a total of eight specimens. Test variables included the GFRP strip-width-to-spacing ratio and type of opening array. The specimen with a GFRP plate with a 3×2 opening array showed the highest shear strength. From the test results, the shear strength increased as the strip-width-to-strip-spac...

  7. Retrofitting of Reinforced Concrete Beams using Reactive Powder Concrete (RPC)

    Science.gov (United States)

    Karthik, S.; Sundaravadivelu, Karthik

    2017-07-01

    Strengthening of existing damaged structures is one of the leading studies in civil engineering. The purpose of retrofitting is to structurally treat the member with an aim to restore the structure to its original strength. The focus of this project is to study the behaviour of damaged Reinforced Concrete beam retrofitted with Reactive Powder Concrete (RPC) Overlay. Reinforced concrete beams of length 1200 mm, width 100 mm and depth 200 mm were casted with M30 grade of concrete in the laboratory and cured for 28 days. One beam is taken as control and are tested under two point loading to find out ultimate load. Remaining beams are subjected to 90 % ultimate load of control beams. The partially damaged beams are retrofitted with Reactive Powder Concrete Overlay at the full tension face of the beam and side overlay depends upon the respectable retrofitting techniques with 10 mm and 20 mm thick layer to find optimum. Materials like steel fibres are added to enhance the ductility by eliminating coarse particle for homogeneity of the structure. Finally, the modes of failure for retrofitted beams are analysed experimentally under two point loading & compared the results with Control beam.

  8. What Happens with Reinforced Concrete Structures when the Reinforcement Corrodes

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    In this paper, corrosion of reinforced concrete structures is discussed from the point of view of corrosion products. The different types of corrosion products are presented and a detailed study of the important diffusion coefficient is performed. Stochastic modelling of corrosion initiated...

  9. Frost resistance of fibre reinforced concrete structures

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place

    1999-01-01

    of 0.4-1% by volume of fibres cannot replace air entrainment in order to secure a frost resistant concrete; the minimum amount of air needed to make the concrete frost resistant is not changed when adding fibres· the amount of air entrainment must be increased when fibres are added to establish......Frost resistance of fibre reinforced concrete with 2.5-4.2% air and 6-9% air (% by volume in fresh concrete) casted in the laboratory and in-situ is compared. Steel fibres with hooked ends (ZP, length 30 mm) and polypropylene fibres (PP, CS, length 12 mm) are applied. It is shown that· addition...

  10. Ductility Performance of Hybrid Fibre Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    S. Eswari

    2008-01-01

    Full Text Available This study presents a study on the ductility performance of hybrid fibre reinforced concrete. The influence of fibre content on the ductility performance of hybrid fibre reinforced concrete specimens having different fibre volume fractions was investigated. The parameters of investigation included modulus of rupture, ultimate load, service load, ultimate and service load deflection, crack width, energy ductility and deflection ductility. A total of 27 specimens, 100×100×500 mm, were tested to study the above parameters. The specimens incorporated 0.0 to 2.0% volume fraction of polyolefin and steel fibres in different proportions. The ductility performance of hybrid fibre reinforced concrete specimens was compared with that of plain concrete. The test results show that addition of 2.0% by volume of hybrid fibres improves the ductility performance appreciably. An adaptive Neuro-Fuzzy based model has been proposed to predict the ductility performance characteristics. A reasonably close agreement has been obtained between the experimental and predicted results.

  11. Random Time Dependent Resistance Analysis on Reinforced Concrete Structures

    Institute of Scientific and Technical Information of China (English)

    GUAN Chang-sheng; WU Ling

    2002-01-01

    The analysis method on random time dependence of reinforced concrete material is introduced,the effect mechanism on reinforced concrete are discussed, and the random time dependence resistance of reinforced concrete is studied. Furthermore, the corrosion of steel bar in reinforced concrete structures is analyzed. A practical statistical method of evaluating the random time dependent resistance, which includes material, structural size and calculation influence, is also established. In addition, an example of predicting random time dependent resistance of reinforced concrete structural element is given.

  12. FLEXURAL TOUGHNESS OF STEEL FIBER REINFORCED CONCRETE

    Directory of Open Access Journals (Sweden)

    Fehmi ÇİVİCİ

    2006-02-01

    Full Text Available Fiber concrete is a composite material which has mechanical and physical characteristics unlike plain concrete. One of the important mechanical characteristics of fiber concrete is its energy absorbing capability. This characteristics which is also called toughness, is defined as the total area under the load-deflection curve. A number of composite characteristics such as crack resistance, ductility and impact resistance are related to the energy absorbtion capacity. According to ASTM C 1018 and JSCE SF-4 the calculation of toughness is determined by uniaxial flexural testing. Fiber concrete is often used in plates such as bridge decks, airport pavements, parking areas, subjected to cavitation and erosion. In this paper, toughness has been determined according to ASTM C 1018 and JSCE SF-4 methods by testing beam specimens. Energy absorbing capacities of plain and steel fiber reinforced concrete has been compared by evaluating the results of two methods. Also plain and steel fiber reinforced plate specimens behaviors subjected to biaxial flexure are compared by the loaddeflection curves of each specimen.

  13. Strength of Cracked Reinforced Concrete Disks

    DEFF Research Database (Denmark)

    Hoang, Cao Linh; Nielsen, Mogens Peter

    1999-01-01

    The paper deals with models, based on the theory of plasticity, to be used in strength assessments of reinforced concrete disks suffering from different kinds of cracking. Based on the assumption that the sliding strength of concrete is reduced in sections where cracks are located, solutions...... for the shear strength of disks with initial cracks and disks suffering from isotropic cracking are presented. Furthermore, in the case of isotropicly cracked disks subjected to arbitrary in-plane loading, a general yield condition is derived....

  14. Tensile behavior and tension stiffening of reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    Choun, Young Sun; Seo, Jeong Moon

    2001-03-01

    For the ultimate behavior analysis of containment buildings under severe accident conditions, a clear understanding of tensile behaviors of plain and reinforced concrete is necessary. Nonlinear models for tensile behaviors of concrete are also needed. This report describe following items: tensile behaviors of plain concrete, test results of reinforced concrete panels in uniaxial and biaxial tension, tension stiffening. The tensile behaviors of reinforced concrete are significantly influenced by the properties of concrete and reinforcing steel. Thus, for a more reliable evaluation of tensile behavior and ultimate pressure capacity of a reinforced or prestressed concrete containment building, an advanced concrete model which can be considered rebar-concrete interaction effects should be developed. In additions, a crack behavior analysis method and tension stiffening models, which are based on fracture mechanics, should be developed. The model should be based on the various test data from specimens considering material and sectional properties of the containment building.

  15. Shear Behavior of Concrete Beams Reinforced with GFRP Shear Reinforcement

    Directory of Open Access Journals (Sweden)

    Heecheul Kim

    2015-01-01

    Full Text Available This paper presents the shear capacities of concrete beams reinforced with glass fiber reinforced polymer (GFRP plates as shear reinforcement. To examine the shear performance, we manufactured and tested a total of eight specimens. Test variables included the GFRP strip-width-to-spacing ratio and type of opening array. The specimen with a GFRP plate with a 3×2 opening array showed the highest shear strength. From the test results, the shear strength increased as the strip-width-to-strip-spacing ratio increased. Also, we used the experimental results to evaluate whether the shear strength equations of ACI 318-14 and ACI 440.1R can be applied to the design of GFRP shear reinforcement. In the results, the ACI 440 equation underestimated the experimental results more than that of ACI 318.

  16. Strength Evaluation of Steel-Nylon Hybrid Fibre Reinforced Concrete

    OpenAIRE

    Maniram Kumar; Er. Ankush Khadwal

    2014-01-01

    When fibres like steel, glass, polypropylene, nylon, carbon, aramid, polyester, jute, etc are mixed with concrete known as fibre reinforced concrete. To overcome the deficiencies of concrete; fibres are added to improve the performance of concrete. In this research hybrid reinforced concrete is made by using steel and nylon 6 fibres. The inclusion of both steel and nylon 6 fibres are used in order to combine the benefits of both fibers; structural improvements provided by stee...

  17. Ductility of Reinforced Concrete Structures in Flexure

    DEFF Research Database (Denmark)

    Hestbech, Lars

    2013-01-01

    In this thesis, a rotational capacity model for flexural reinforced concrete elements is presented. The model is based on the general assumption, that any other failure mode than bending is prevented by proper design. This includes failure due to shear, anchorage, concentrated loads etc. Likewise......, beams governed by failure described by Kani’s Valley are not covered by the presented model. Hence, the model is delimited to shear reinforced elements failing in flexure. The rotational capacity model is divided into the following calculation procedures. 1. A cross sectional analysis of the critical...... are not necessarily so. An example shows the applicability of the model and a parametric study shows the advantages of the model compared with code provisions. Finally, improvements of the compression zone modelling is performed in order to include a better performance when concrete crushing is the failure criterion...

  18. Flexural strength enhancement of confined reinforced concrete columns

    OpenAIRE

    Pam, HJ; Ho, JCM

    2001-01-01

    As part of a continuing research study, this paper proposes a new design aid to calculate the actual moment capacity of confined reinforced concrete columns. Up to now the moment capacity of a reinforced concrete column is calculated based on the code's guidelines for an unconfined section. As most reinforced concrete columns contain transverse or confining reinforcement, which will enhance the column moment capacity, the actual moment capacity will be much higher than the unconfined moment c...

  19. Concrete cover cracking due to uniform reinforcement corrosion

    DEFF Research Database (Denmark)

    Solgaard, Anders Ole Stubbe; Michel, Alexander; Geiker, Mette Rica;

    2013-01-01

    is calculated using literature data on corrosion rate and Faraday’s law. The parameters varied comprise reinforcement diameter, concrete cover thickness and concrete material properties, viz. concrete tensile strength and ductility (plain concrete and fibre reinforced concrete). Results obtained from......Service life design (SLD) is an important tool for civil engineers to ensure that the structural integrity and functionality of the structure is not compromised within a given time frame, i.e. the service life. In SLD of reinforced concrete structures, reinforcement corrosion is of major concern...... and reinforcement de-passivation is a frequently used limit state. The present paper investigates an alternative limit state: corrosion-induced cover cracking. Results from numerical simulations of concrete cover cracking due to reinforcement corrosion are presented. The potential additional service life...

  20. Flow modelling of steel fibre reinforced self-compacting concrete

    DEFF Research Database (Denmark)

    Svec, Oldrich

    Concrete is one of the most widely used materials in the world. Ordinary concrete composition makes the material strong in compression yet weak and brittle in tension. Steel reinforced concrete successfully eliminates the weak tensile properties of the ordinary concrete. Steel fibres dispersed...... in concrete can efficiently substitute or supplement conventional steel reinforcement, such as reinforcement bars. Ordinary concrete composition further makes the material stiff and non-flowable. Self-compacting concrete is an alternative material of low yield stress and plastic viscosity that does flow...... and fills the formwork with a little or no effort. Steel fibre reinforced self-compacting concrete is a logical combination of the two types of concrete. The combination nevertheless creates several challenges. It has been observed by many authors that steel fibres orient and distribute according...

  1. Long term behavior of self-compacting reinforced concrete beams

    Institute of Scientific and Technical Information of China (English)

    LIU Xiao-jie; YU Zhi-wu; JIANG Li-zhong

    2008-01-01

    Tests were carded out on 8 self-compacting reinforced concrete(SCC) beams and 4 normal reinforced concrete beams. The effects of mode of consolidation, load level, reinforcing ratio and structural type on long term behavior of SCC were investigated. Under the same environmental conditions, the shrinkage-time curve of self-compacting concrete beam is very similar to that of normal concrete beam. For both self-compacting reinforced concrete beams and normal reinforced concrete beams, the rate of shrinkage at early stages is higher, the shrinkage strain at 2 months is about 60% of the maximum value at one year. The shrinkage strain of self-compacting reinforced concrete beam after one year is about 450×10-6. Creep deflection of self-compacting reinforced concrete beam decreases as the tensile reinforcing ratio increases. The deflection creep coefficient of self-compacting reinforced concrete beam after one and a half year is about 1.6, which is very close to that of normal reinforced concrete beams cast with vibration. Extra cautions considering shrinkage and creep behavior are not needed for the use of SCC in engineering practices.

  2. Theoretical study for Bond between Reinforcement steel and Concrete

    Directory of Open Access Journals (Sweden)

    usama mostafa mahran

    2013-04-01

    Full Text Available The behavior and load carrying behavior of reinforced concrete structures is influence by the interaction between the concrete and reinforcement. The stress transfer between reinforcement and concrete in the longitudinal direction of the bars is called bond. An essential feature of reinforced concrete is the bond between steel and concrete. Anchorage of reinforcement depends on the bond between steel and concrete, crack width and crack spacing are mainly governed by it. So, stiffness, deformation and dynamic behavior are influenced by it, and in reverse loading damping and energy dissipation is a function of bond. This is one of the reasons why bond has been, and still is, a topic of fundamental and applied research. Bond stress is the equivalent unit shear stress acting in parallel to the reinforcing bar on the interface between reinforcing steel bar and concrete. Due to the transfer of forces through bond stress, between the reinforcing rebar and concrete, the force in the reinforcing bar changes along its length. Because bond stress is thought of as stress per unit area of bar surface, it is related to the rate of change of steel stress. Consequently, to have bond stress it is necessary to have a changing steel stress. In cases of high stress at the contact interface, near cracks or end anchorages, the bond stresses are related to relative displacements between concrete and steel. These relative displacements, which are caused by different average strains in the concrete and the steel, are usually called bond-slip (t-d.

  3. The effect of concrete strength and reinforcement on toughness of reinforced concrete beams

    OpenAIRE

    Carneiro, Joaquim A. O.; Jalali, Said; Teixeira, Vasco M. P.; Tomás, M.

    2005-01-01

    The objective pursued with this work includes the evaluating of the strength and the total energy absorption capacity (toughness) of reinforced concrete beams using different amounts of steel-bar reinforcement. The experimental campaign deals with the evaluation of the threshold load prior collapse, ultimate load and deformation, as well as the beam total energy absorption capacity, using a three point bending test. The beam half span displacement was measured using a displacement transducer,...

  4. Performance of steel-making slag concrete reinforced with fibers

    OpenAIRE

    Ortega-López Vanesa; Fuente-Alonso José Antonio; Skaf Marta; Santamaría Amaia; Aragón Ángel; Manso Juan Manuel

    2017-01-01

    In this research, the possibility of making concrete reinforced with fibers and manufactured with recycled aggregates from carbon steel production was explored. Electric arc furnace slag (EAFS) was used as coarse and medium aggregate, and part of the sand sizes. Metallic and synthetic fibers were added in different amounts. Initially, the properties of EAFS and their suitability to be used in the manufacture fiber reinforced concrete were analysed. Then, a series of fiber reinforced concrete ...

  5. ANALYSIS OF EXPOSURE OF REINFORCED CONCRETE BUILDINGS TO TEMPERATURE LOADS

    OpenAIRE

    2012-01-01

    The co-authors consider the problem of analysis of building structures in respect of combined effects of forces and temperatures. Results of fire tests of reinforced concrete walls and slabs are presented. Overview of the analysis of the fire resistance of reinforced-concrete buildings is also provided. As a result of the research, numerical solutions were obtained in respect of deflections, stresses, deformations and internal forces arising in a reinforced concrete bearing wall and plate...

  6. Durability of GFRP reinforcing bars and their bond in concrete

    OpenAIRE

    Rolland, Arnaud; Chataigner, Sylvain; Quiertant, Marc; Benzarti, Karim; Argoul, Pierre

    2015-01-01

    The use of composite reinforcing bars (rebars) for the reinforcement of concrete appears as an attractive solution to prevent corrosion, which is the main pathology encountered on concrete structures. Although such rebars are being used for more than ten years, there is a clear lack of knowledge regarding their durability, especially under alkaline environment. This paper aims at investigating the evolutions of tensile properties and bond in concrete of GFRP (Glass Fiber Reinforced Polymer...

  7. Reinforced concrete design to Eurocode 2

    CERN Document Server

    Toniolo, Giandomenico

    2017-01-01

    This textbook describes the basic mechanical features of concrete and explains the main resistant mechanisms activated in the reinforced concrete structures and foundations when subjected to centred and eccentric axial force, bending moment, shear, torsion and prestressing,. It presents a complete set of limit-state design criteria of the modern theory of RC incorporating principles and rules of the final version of the official Eurocode 2. This textbook examines methodological more than notional aspects of the presented topics, focusing on the verifications of assumptions, the rigorousness of the analysis and the consequent degree of reliability of results. Each chapter develops an organic topic, which is eventually illustrated by examples in each final paragraph containing the relative numerical applications. These practical end-of-chapter appendices and intuitive flow-charts ensure a smooth learning experience. The book stands as an ideal learning resource for students of structural design and analysis cou...

  8. Reliability of Reinforced Concrete Buildings During Construction

    Institute of Scientific and Technical Information of China (English)

    方东平; 耿川东; 张传敏; 祝宏毅; 刘西拉

    2004-01-01

    The safety analysis of reinforced concrete buildings during construction should be based on the comprehensive understanding of loads, load effects, structural resistance, and available safety index of the structure. This paper analyzes the characteristics and probabilistic models of resistance, loads, and load effects. A method was developed to calculate the probability of failure based on Monte Carlo simulation and models proposed in previous articles. Construction examples were used to analyze the influence of live load on the probability of failure. The results show that when the live load increases, the maximum probability of failure increases with acceleration. The results suggest that the construction live load should be carefully addressed during construction.

  9. Design of Reinforced Concrete Elements Under Fire

    Directory of Open Access Journals (Sweden)

    P. Mihai

    2008-01-01

    Full Text Available Fire safety regulations can have a major impact on many aspects of the overall design of a building, including layout, aesthetics, function, and cost. Rapid developments in modern building technology in the last decades often have resulted in unconventional structures and design solutions. Because the world is developed continuously, the physical size of buildings increases continually; there is a tendency to build large underground car parks, warehouses, and shopping complexes. As a result, we have a worldwide movement to replace prescriptive building codes with ones based on performance. The paper presents the basic principles for the designing process of reinforced concrete elements under fire.

  10. Rockfall vulnerability assessment for reinforced concrete buildings

    Directory of Open Access Journals (Sweden)

    O. Mavrouli

    2010-10-01

    Full Text Available The vulnerability of buildings to the impact of rockfalls is a topic that has recently attracted increasing attention in the scientific literature. The quantification of the vulnerability, when based on empirical or heuristic approaches requires data recorded from historical rockfalls, which are not always available. This is the reason why appropriate alternatives are required. The use of analytical and numerical models can be one of them. In this paper, a methodology is proposed for the analytical evaluation of the vulnerability of reinforced concrete buildings. The vulnerability is included in the risk equation by incorporating the uncertainty of the impact location of the rock block and the subsequent damage level. The output is a weighted vulnerability that ranges from 0 to 1 and expresses the potential damage that a rock block causes to a building in function of its velocity and size. The vulnerability is calculated by the sum of the products of the probability of block impact on each element of the building and its associated damage state, the latter expressed in relative recovery cost terms. The probability of exceeding a specific damage state such as non-structural, local, partial, extensive or total collapse is also important for the quantification of risk and to this purpose, several sets of fragility curves for various rock diameters and increasing velocities have been prepared. An example is shown for the case of a simple reinforced concrete building and impact energies from 0 to 4075 kJ.

  11. Monitoring corrosion in reinforced concrete structures

    Science.gov (United States)

    Kung, Peter; Comanici, Maria I.

    2014-06-01

    Many defects can cause deterioration and cracks in concrete; these are results of poor concrete mix, poor workmanship, inadequate design, shrinkage, chemical and environmental attack, physical or mechanical damage, and corrosion of reinforcing steel (RS). We want to develop a suite of sensors and systems that can detect that corrosion is taking place in RS and inform owners how serious the problem is. By understanding the stages of the corrosion process, we can develop special a sensor that detects each transition. First, moisture ingress can be monitored by a fiber optics humidity sensor, then ingress of Chloride, which acts as a catalyst and accelerates the corrosion process by converting iron into ferrous compounds. We need a fiber optics sensor which can quantify Chloride ingress over time. Converting ferric to ferrous causes large volume expansion and cracks. Such pressure build-up can be detected by a fiber optic pressure sensor. Finally, cracks emit acoustic waves, which can be detected by a high frequency sensor made with phase-shifted gratings. This paper will discuss the progress in our development of these special sensors and also our plan for a field test by the end of 2014. We recommend that we deploy these sensors by visually inspecting the affected area and by identifying locations of corrosion; then, work with the designers to identify spots that would compromise the integrity of the structure; finally, drill a small hole in the concrete and insert these sensors. Interrogation can be done at fixed intervals with a portable unit.

  12. Containment performance evaluation of prestressed concrete containment vessels with fiber reinforcement

    Energy Technology Data Exchange (ETDEWEB)

    Choun, Young Sun; Park, Hyung Kui [Integrated Safety Assessment Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-12-15

    Fibers in concrete resist the growth of cracks and enhance the postcracking behavior of structures. The addition of fibers into a conventional reinforced concrete can improve the structural and functional performance of safety-related concrete structures in nuclear power plants. The influence of fibers on the ultimate internal pressure capacity of a prestressed concrete containment vessel (PCCV) was investigated through a comparison of the ultimate pressure capacities between conventional and fiber-reinforced PCCVs. Steel and polyamide fibers were used. The tension behaviors of conventional concrete and fiber-reinforced concrete specimens were investigated through uniaxial tension tests and their tension-stiffening models were obtained. For a PCCV reinforced with 1% volume hooked-end steel fiber, the ultimate pressure capacity increased by approximately 12% in comparison with that for a conventional PCCV. For a PCCV reinforced with 1.5% volume polyamide fiber, an increase of approximately 3% was estimated for the ultimate pressure capacity. The ultimate pressure capacity can be greatly improved by introducing steel and polyamide fibers in a conventional reinforced concrete. Steel fibers are more effective at enhancing the containment performance of a PCCV than polyamide fibers. The fiber reinforcement was shown to be more effective at a high pressure loading and a low prestress level.

  13. Anchorage of Main Reinforcement in Lightweight Aggregate Concrete Beams

    DEFF Research Database (Denmark)

    Larsen, Henning

    1999-01-01

    The paper deals with the anchorage of reinforcement bars at end supports in beam component made of lightweight aggregate concrete with open structure.......The paper deals with the anchorage of reinforcement bars at end supports in beam component made of lightweight aggregate concrete with open structure....

  14. Computational modelling of chloride ion transport in reinforced concrete

    NARCIS (Netherlands)

    Meijers, S.J.H.; Bijen, J.M.J.M.; De Borst, R.; Fraaij, A.L.A.

    2001-01-01

    Exposure to a saline environment is a major threat with respect to the durability of reinforced concrete structures. The chloride ions, which are present in seawater and de-icing salts, are able to penetrate the concrete up to the depth of the reinforcement. They can eventually trigger a pitting cor

  15. Normal Strength Steel Fiber Reinforced Concrete Subjected to Explosive Loading

    Directory of Open Access Journals (Sweden)

    Mohammed Alias Yusof

    2011-07-01

    Full Text Available This paper presents the results of an experimental investigation on the behavior of plain reinforced concrete and Normal strength steel fiber reinforced concrete panels (SFRC subjected to explosive loading. The experiment were performed by the Blast Research Unit Faculty of Engineering, University Pertahanan Nasional Malaysia A total of 8 reinforced concrete panels of 600mm x 600mm x 100mm were tested. The steel fiber reinforced concrete panels incorporated three different volume fraction, 0.5%, 1.0%, and 1.5% of hooked end steel fibers. The panels were subjected to explosive loading generated by the detonation of 1kg of explosive charge located at a 0.6m standoff. This investigation indicates that the steel fiber reinforced concrete panel containing of 1.5% volume fraction gave the best performance under explosive loading.

  16. Transporting fibres as reinforcement in self-compacting concrete

    NARCIS (Netherlands)

    Grünewald, S.; Walraven, J.C.

    2009-01-01

    The development of self-compacting concrete (SCC) was an important step towards efficiency at building sites, rationally producing prefabricated concrete elements, better working conditions and improved quality and appearance of concrete structures. By adding fibres to SCC bar reinforcement can be

  17. Flexural strength and ductility of reinforced concrete beams

    OpenAIRE

    Kwan, AKH; Ho, JCM; Pam, HJ

    2002-01-01

    In the design of reinforced concrete beams, especially those made of high-strength concrete and those in earthquake-resistant structures, both the flexural strength and ductility need to be considered. From the numerical results obtained in a previous study on the post-peak behaviour and flexural ductility of reinforced concrete beams, the interrelation between the flexural strength and the flexural ductility that could be simultaneously achieved was evaluated and plotted in the form of chart...

  18. Evaluation of seismic shear capacity of prestressed concrete containment vessels with fiber reinforcement

    Energy Technology Data Exchange (ETDEWEB)

    Choun, Young Sun; Park, Jun Hee [Integrated Safety Assessment Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Fibers have been used in cement mixture to improve its toughness, ductility, and tensile strength, and to enhance the cracking and deformation characteristics of concrete structural members. The addition of fibers into conventional reinforced concrete can enhance the structural and functional performances of safety-related concrete structures in nuclear power plants. The effects of steel and polyamide fibers on the shear resisting capacity of a prestressed concrete containment vessel (PCCV) were investigated in this study. For a comparative evaluation between the shear performances of structural walls constructed with conventional concrete, steel fiber reinforced concrete, and polyamide fiber reinforced concrete, cyclic tests for wall specimens were conducted and hysteretic models were derived. The shear resisting capacity of a PCCV constructed with fiber reinforced concrete can be improved considerably. When steel fiber reinforced concrete contains hooked steel fibers in a volume fraction of 1.0%, the maximum lateral displacement of a PCCV can be improved by > 50%, in comparison with that of a conventional PCCV. When polyamide fiber reinforced concrete contains polyamide fibers in a volume fraction of 1.5%, the maximum lateral displacement of a PCCV can be enhanced by ∼40%. In particular, the energy dissipation capacity in a fiber reinforced PCCV can be enhanced by > 200%. The addition of fibers into conventional concrete increases the ductility and energy dissipation of wall structures significantly. Fibers can be effectively used to improve the structural performance of a PCCV subjected to strong ground motions. Steel fibers are more effective in enhancing the shear performance of a PCCV than polyamide fibers.

  19. Bond tests of fiberglass-reinforced plastic bars in concrete

    Energy Technology Data Exchange (ETDEWEB)

    Larralde, J.; Silva-Rodriquez, R.; Burdette, J.; Harris, B. (Drexel Univ., Philadelphia, PA (United States). Civil and Architectural Engineering Dept.)

    1994-07-01

    Fiberglass Reinforced Plastic (FRP) bars for concrete reinforcement have been commercially available for several years. The main advantage of such bar relative to the conventional steel reinforcing bars is their resistance to corrosion. The reinforced plastic bars are slightly different from the conventional steel bars both geometrically and mechanically. Thus, research is needed to understand their behavior and to be able to use them in concrete reinforcement with adequate reliability. Bond strength of reinforced plastic bars in concrete is one of the mechanical and behavioral differences with the steel bars. This paper presents the results of pullout and beam tests conducted to determine the bond stress-slip behavior of FRP bars in concrete.

  20. Neutron imaging of water penetration into cracked steel reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, P. [Center for Durability and Sustainability Studies of Shandong Province, Qingdao Technological University, Qingdao 266033 (China); Wittmann, F.H., E-mail: wittmann@aedificat.d [Center for Durability and Sustainability Studies of Shandong Province, Qingdao Technological University, Qingdao 266033 (China); Aedificat Institute Freiburg, Schlierbergstr. 80, D-79100 Freiburg (Germany); Zhao, T. [Center for Durability and Sustainability Studies of Shandong Province, Qingdao Technological University, Qingdao 266033 (China); Lehmann, E.H. [Neutron Imaging and Activation Group (NIAG), Paul Scherrer Institute, CH-5232 Villigen PSI (Switzerland)

    2010-04-01

    Service life and durability of reinforced concrete structures have become a crucial issue because of the economical and ecological implications. Service life of reinforced concrete structures is often limited by penetration of water and chemical compounds dissolved in water into the porous cement-based material. By now it is well-known that cracks in reinforced concrete are preferential paths for ingress of aggressive substances. Neutron radiography was successfully applied to study the process of water penetration into cracked steel reinforced concrete. In addition, the effectiveness of integral water repellent concrete to prevent ingress of water and salt solutions was investigated. Results are described in detail in this contribution. It will be shown that neutron radiography is a powerful method to visualize the process of water penetration into cracked and uncracked cement-based materials. On the basis of the obtained experimental data, it is possible to quantify the time-dependent water distributions in concrete with high accuracy and spatial resolution. It is of particular interest that penetration of water and salt solutions into damaged interfaces between concrete and steel can be visualized by means of neutron radiography. Deteriorating processes in cracked reinforced concrete structures can be studied in a completely new way. This advanced technology will help and find adequate ways to improve durability and service life of reinforced concrete structures. This will mean at the same time an essential contribution to improved sustainability.

  1. Numerical Limit Analysis of Reinforced Concrete Structures

    DEFF Research Database (Denmark)

    Larsen, Kasper Paaske

    methods provide engineers with valuable tools for limit sta- te analysis, their application becomes difficult with increased structural complexity. The main challenge is to solve the optimization problem posed by the extremum principles. This thesis is a study of how numerical methods can be used to solve...... limit state analysis problems. The work focuses on determination of the load bearing capacity of reinforced concrete structures by employing the lower bound theorem and a finite element method using equilibrium elements is developed. The recent year’s development within the field of convex optimization...... is developed for improved perfor- mance. An example is given in which an inverse T-beam is analyzed and the numerical results are compared to laboratory tests. The third and final element is a plane shell element capable of modeling membrane and plate bending behavior. The element employs a layered disk...

  2. Tendons Arrangement Effects on Reinforced Concrete Frames

    Directory of Open Access Journals (Sweden)

    Ayad B. Bahnam

    2013-05-01

    Full Text Available  The tendons arrangement effects on the response of reinforced concrete frame experiencing blast loads is investigated in this paper. The structure is modeled using nonlinear finite elements employing a bilinear hysteretic model. So that elements are used so that yielding of the structures could be accurately modeled and captured. The frame is analyzed using a non-linear, elastic-plastic finite element program written in code MATLAB. Six tendon architectures were investigated. A single tendon was placed between different floors and its effects investigated. From the obtained results, the ideal case which causes a reduction in the maximum displacement and the amount of permanent deflection without increase in the maximum structural shear forces greatly is obtained.

  3. Experimental investigation of the relation between damage at the concrete-steel interface and initiation of reinforcement corrosion in plain and fibre reinforced concrete

    DEFF Research Database (Denmark)

    Michel, Alexander; Solgaard, Anders Ole Stubbe; Pease, Bradley Justin;

    2013-01-01

    Cracks in covering concrete are known to hasten initiation of steel corrosion in reinforced concrete structures. To minimise the impact of cracks on the deterioration of reinforced concrete structures, current approaches in (inter)national design codes often limit the concrete surface crack width....... Recent investigations however, indicate that the concrete-reinforcement interfacial condition is a more fundamental criterion related to reinforcement corrosion. This work investigates the relation between macroscopic damage at the concrete-steel interface and corrosion initiation of reinforcement...... embedded in plain and fibre reinforced concrete. Comparisons of experimental and numerical results indicate a strong correlation between corrosion initiation and interfacial condition....

  4. CREATION OF MUSIC WITH FIBER REINFORCED CONCRETE

    Science.gov (United States)

    Kato, Hayato; Takeuchi, Masaki; Ogura, Naoyuki; Kitahara, Yukiko; Okamoto, Takahisa

    This research focuses on the Fiber Reinforcement Concrete(FRC) and its performance on musical tones. Thepossibility of future musical instruments made of this concrete is discussed. Recently, the technical properties of FRC had been improved and the different production styles, such as unit weight of binding material and volume of fiber in the structure, hardly affects the results of the acoustics. However, the board thickness in the FRC instruments is directly related with the variety of musical tone. The FRC musical effects were compared with those produced with wood on wind instruments. The sounds were compared with those produced with woodwind instruments. The sound pressure level was affected by the material and it becomes remarkably notorious in the high frequency levels. These differences had great influence on the spectrum analysis of the tone in the wind instruments and the sensory test. The results from the sensory test show dominant performances of brightness, beauty and power in the FRC instruments compared with those made of wood.

  5. Mechanical Properties of Layered Hybrid Fiber Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    YUAN Hai-qing; CHEN Jing-tao; ZHU Ji-dong

    2003-01-01

    To improve the mechanical properties of concrete,Layered Hybrid Fiber Reinforced Concrete (LHFRC) was developed in this paper.Through comparative tests,the effects of layered hybrid fibers on a series of mechanical properties of concrete were discussed.The mechanical properties include compressive strength,tensile strength,flexural strength,compressive stress-strain relationship,flexural toughness and cracking resistance of concrete.The testing results and analysis demonstrate that layered hybrid fibers can significantly improve the flexural strength,toughness and cracking resistance of concrete while the cost of concrete increases slightly.

  6. Investigation of basalt plastic reinforcement and its Adhesion with Concrete

    Directory of Open Access Journals (Sweden)

    Kustikova Yulia Olegovna

    2014-03-01

    Full Text Available The load-bearing capacity and durability of concrete structures with metal or other reinforcement depends on their physical and mechanical properties and adhesion values with concrete. In this regard, there is an urgent need in the definition of adhesion of basalt reinforcement and concrete of various compositions and classes. One of the main problems with the use of basalt rods in concrete structures is - providing a high degree of load-carrying capacity in different conditions of stress-strain state of the structure, and the related amount of its adhesion with concrete. Meeting these requirements can be achieved with load-bearing capacity of individual rods, adhesion value, in general, of basalt reinforcement with concrete.

  7. Flexural behavior of reinforced concrete beams: Comparative analysis between high-performance concrete and ordinary concrete

    Directory of Open Access Journals (Sweden)

    Hamrat Mostefa

    2014-04-01

    Full Text Available This paper presents an experimental study on the flexural strength of reinforced concrete beams made with high performance concrete (HPC and ordinary concrete (OC. We are carried an experimental campaign aimed comes in three points: 1- the study of the law of behavior of the two materials (OC and HPC, 2- the influence of the compressive strength of concrete and the rate of longitudinal reinforcement on the loaddeflection behavior and ductility index, 3- comparative analysis (ACI318, Eurocode 2 and BS8110 against the crack opening. Test results showed that the capacity of the beams in HPC is higher (6% to 20 % than the beams in OC. The use of HPC is more efficient than the OC to delay the first cracking. The average value of the ductility index for the beams in HPC is 1.30 times those beams in OC. The formula for calculating the crack opening derived of the Eurocode 2 gives the best prediction the crack width of beams (for both types of concrete.

  8. Transport and Corrosion Behavior of Cracked Reinforced Concrete

    DEFF Research Database (Denmark)

    Pease, Bradley Justin

    to enter the concrete. This is, among others, important in the corrosion of reinforcing steel. When cracks protrude to the depth of reinforcing steel, liquids containing aggressive ions (i.e. chlorides associated with salts and sea water) may rapidly access and initiate corrosion of the reinforcing...... structures. These models currently lack some of the scientific validity to fully represent actual field structures, i.e. structures containing cracks. Further understanding, therefore is needed on the effect cracks have on transport and corrosion in reinforced concrete. The fundamental mechanisms...... of transport and corrosion in cracked, reinforced concrete are not yet fully understood. The scope of this study therefore is to develop a link between concrete cracks and the relevant transport mechanism(s) under particular environmental conditions. It is envisioned that a finite element model...

  9. Shear reinforced beams in autoclaved aerated concrete

    DEFF Research Database (Denmark)

    Cornelius, Thomas

    2010-01-01

    Shear behaviour in concrete materials is very well documented, for normal density concrete materials. In this paper results of various tests on low density concrete materials like aerated autoclaved concrete (in the following denoted aircrete) will be presented and analyzed for different combinat......Shear behaviour in concrete materials is very well documented, for normal density concrete materials. In this paper results of various tests on low density concrete materials like aerated autoclaved concrete (in the following denoted aircrete) will be presented and analyzed for different...

  10. The Reinforced Concrete Structure Reinforcement Technology%钢筋混凝土结构加固技术

    Institute of Scientific and Technical Information of China (English)

    李孝余

    2014-01-01

    This article mainly from the carbon fiber reinf-orcement technology, grouting reinforcement technology, che.-mical y-planted steel bars technology, change the stress system, etc. to discuss the reinforced concrete structure reinforcement technology and carries on the comprehensive comparison of these methods.%本文主要从碳纤维加固技术、注浆加固技术、化学植筋技术、改变受力体系等方面,论述了钢筋混凝土结构加固技术,并对这几种方法进行了全面对比。

  11. Surface treated polypropylene (PP) fibres for reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    López-Buendía, Angel M., E-mail: buendia@uv.es [AIDICO Technological Institute of Construction, Benjamin Franklin 17, 46380 Paterna, Valencia (Spain); Romero-Sánchez, María Dolores [AIDICO Technological Institute of Construction, Marble Technical Unit, Camí de Castella 4, 03660 Novelda. Alicante (Spain); Climent, Verónica [Lafarge Cementos, Polígono Sepes, Isaac Newton s/n, 46500 Sagunto, Valencia (Spain); Guillem, Celia [AIDICO Technological Institute of Construction, Marble Technical Unit, Camí de Castella 4, 03660 Novelda. Alicante (Spain)

    2013-12-15

    Surface treatments on a polypropylene (PP) fibre have contributed to the improvement of fibre/concrete adhesion in fibre-reinforced concrete. The treatments to the PP fibre were characterized by contact angle measurements, ATR-IR and XPS to analyse chemical alterations. The surface topography and fibre/concrete interaction were analysed by several microscopic techniques, namely optical petrographic, and scanning electron microscopy. Treatment modified the surface chemistry and topography of the fibre by introducing sodium moieties and created additional fibre surface roughness. Modifications in the fibre surface led to an increase in the adhesion properties between the treated fibres and concrete and an improvement in the mechanical properties of the fibre-reinforced concrete composite as compared to the concrete containing untreated PP fibres. Compatibility with the concrete and increased roughness and mineral surface was also improved by nucleated portlandite and ettringite mineral association anchored on the alkaline PP fibre surface, which is induced during treatment.

  12. The Mechanical Properties of Polypropylene Fiber Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    LI Bei-xing; CHEN Ming-xiang; CHENG Fang; LIU Lu-ping

    2004-01-01

    The compressive, shear strengths and abrasion-erosion resistance as well as flexural properties of two polypropylene fiber reinforced concretes and the comparison with a steel fiber reinforced concrete were reported.The exprimental results show that a low content of polypropylene fiber (0.91kg/m3 of concrete) slightly decreases the compressive and shear strengths, and appreciably increased the flexural strength, but obviously enhances the toughness index and fracture energy for the concrete with the same mix proportion, consequently it plays a role of anti-cracking and improving toughness in concrete. Moreover, the polypropylene mesh fiber is better than the polypropylene monofilament fiber in improving flexural strength and toughness of concrete, but the two types of polypropylene fibers are inferior to steel fiber. All the polypropylene and steel fibers have no great beneficial effect on the abrasion-erosion resistance of concrete.

  13. Bond Properties and Experimental Methods of Textile Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Textile reinforced concrete(TRC, for short) allows the low size production and offers a high effectiveness of the reinforcement by using continuous roving instead of short-chopped fibers. However, whether textiles can cooperate with concrete very well depends on the bond between them. In this paper, the bonding mechanism that the stress was transferred from fine concrete to textile was analyzed, and the influences of the initial bond length of textile, the surface treatment of textile, the strength and workability of concrete as well as the level of prestressing force on bond behavior were investigated on the basis of pull-out tests. The results reveal that with initial bond length increasing, the maximum pull force increases, and increasing concrete strength and improving workability of concrete matrix, epoxy resin impregnating and sand covering of textile as well as prestressing textile can obviously increase the bond strength between the textile and concrete.

  14. Compressive behaviour at High Temperatures of Fibre Reinforced Concretes

    Directory of Open Access Journals (Sweden)

    S. O. Santos

    2009-01-01

    Full Text Available This paper summarizes the research that is being carried out at the Universities of Coimbra and Rio de Janeiro, on fibre reinforced concretes at high temperatures. Several high strength concrete compositions reinforced with fibres (polypropylene, steel and glass fibres were developed. The results of compressive tests at high temperatures (300 °C, 500 °C and 600 °C and after heating and cooling down of the concrete are presented in the paper. In both research studies, the results indicated that polypropylene fibers prevent concrete spalling. 

  15. DUCTILITY BEHAVIOR FIBER REINFORCED CONCRETE BEAMS STRENGTHENED WITH EXTERNALLY BONDED GLASS FIBER REINFORCED POLYMER LAMINATES

    Directory of Open Access Journals (Sweden)

    Mariappan Mahalingam

    2013-01-01

    Full Text Available The study presents the results of an experimental investigation conducted on Steel Fiber Reinforced Concrete (SFRC beams with externally bonded Glass Fiber Reinforced Polymer (GFRP laminates with a view to study their strength and ductility. A total of ten beams, 150×250 mm in cross-section were tested in the laboratory over an effective span of 2800 mm. Three fiber reinforced concrete beams were used as reference beams. Six fiber reinforced concrete beams were provided with externally bonded GFRP laminates. One concrete beam was left virgin without any fiber reinforcement and external GFRP laminates. All the beams were tested until failure. The variables considered included volume fraction of fiber reinforcement and stiffness of GFRP laminates. The static responses of all the beams were evaluated in terms of strength, stiffness and ductility. The test results show that the beams provided with externally bonded GFRP laminates exhibit improved performance over the beams with internal fiber reinforcement.

  16. Ambient Vibration Test on Reinforced Concrete Bridges

    Directory of Open Access Journals (Sweden)

    Idris Nurul Shazwin

    2016-01-01

    Full Text Available An investigation was carried out to determine dynamic characteristic of reinforced concrete (RC bridges by using ambient vibration test (AVT. The ambient vibration sources on bridges may come from traffic, wind, wave motion and seismic events. AVT describes the dynamic characteristics of the bridge and ground by measuring the natural frequencies using highly sensitive seismometer sensor. This test is beneficial due to light weight equipment and smaller number of operator required, cheap and easy to be handled. It is able to give a true picture of the bridge dynamic behavior without any artificial force excitation when vibration data is recorded. A three-span reinforced concrete bridge located in Sri Medan, Batu Pahat, Johor was measured by using microtremor equipment consist of three units of 1 Hz eigenfrequency passive sensors used in this test was performed in normal operating condition without excitation required from any active sources or short period noise perturbations. Ten measurements were conducted on the bridge deck and ten measurements on the ground surface in order to identify the natural frequencies of the bridge. Several peak frequencies were identified from three components of Fourier Amplitude Spectra (FAS in transverse (North-South, longitudinal (East-West and vertical (Up-Down direction as well as squared average Horizontal to Vertical Spectral Ratio (HVSR of ground response, computed by using Geopsy software. From the result, it was expected the bridge have five vibration modes frequencies in the range of 1.0 Hz and 7.0 Hz with the first two modes in the transverse and longitudinal direction having a frequency 1.0 Hz, the third mode is 2.2 Hz in transverse direction, fourth and fifth mode is 5.8 Hz and 7.0 Hz. For ground natural frequencies are in range 1.0 Hz to 1.3 Hz for North-South direction and 1.0 Hz to 1.6 Hz for East-West direction. Finally the results are compared with several empirical formulas for simple

  17. Stochastic modeling of reinforced concrete structures exposed to chloride attack

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Frier, Christian

    2004-01-01

    the reinforcement exceeds a critical threshold value. In the present paper a stochastic model is described by which the chloride content in a reinforced concrete structure can be estimated. The chloride ingress is modeled by a 2-dimensional diffusion process and the diffusion coefficient, surface chloride......For many reinforced concrete structures corrosion of reinforcement is an important problem since it can result in expensive maintenance and repair actions. Further, a significant reduction of the load-bearing capacity can occur. One mode of corrosion initiation is that the chloride content around...

  18. Experimental Study on Voided Reinforced Concrete Beams with Polythene Balls

    Science.gov (United States)

    Sivaneshan, P.; Harishankar, S.

    2017-07-01

    The primary component in any structure is concrete, that exist in buildings and bridges. In present situation, a serious problems faced by construction industry is exhaustive use of raw materials. Recent times, various methods are being adopted to limit the use of concrete. In structural elements like beams, polythene balls can be induced to reduce the usage of concrete. A simply supported reinforced concrete beam has two zones, one above neutral axis and other below neutral axis. The region below neutral axis is in tension and above neutral axis is in compression. As concrete is weak in tension, steel reinforcements are provided in tension zone. The concrete below the neutral axis acts as a stress transfer medium between the compression zone and tension zone. The concrete above the neutral axis takes minimum stress so that we could partially replace the concrete above neutral axis by creating air voids using recycled polythene balls. Polythene balls of varying diameters of 75 mm, 65 mm and 35 mm were partially replaced in compression zone. Hence the usage of concrete in beams and self-weight of the beams got reduced considerably. The Load carrying capacity, Deflection of beams and crack patterns were studied and compared with conventional reinforced concrete beams.

  19. Experimental Study on Electric Properties of Carbon Fiber Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    According to the phenomenon that the physical properties have a great effect on the electric capability of carbon fiber reinforced concrete, the author researched the relationship between DC resistance of carbon fiber reinforced concrete and curing age using the two-probe method. Then the effect of insulative area,location and quantity on DC resistance of carbon fiber reinforced concrete was investigated at different curing age with analysis of hydration. The results suggest that DC resistance increases greatly with its curing age, which illustrates the relationship like Gaussian curve. In every curing ages the electric capability of carbon fiber reinforced concrete weakenes with the increase of insulative area. In same curing ages, section and insulative area, the more the quantity of insulation, the stronger the conductibility. The insulative location in optimal position can only result in optimal conductibility.

  20. Verification of Properties of Concrete Reinforcement Bars: Nigeria ...

    African Journals Online (AJOL)

    Nekky Umera

    from the producing mills but purchase them as groups of single bars from the ... determining the extent to which they conform to the requirements of. International ... the most widely used bar sizes for the local concrete reinforcement needs.

  1. Bond Strength Degradation of Corrosive Reinforced Lightweight Concrete

    Institute of Scientific and Technical Information of China (English)

    CHEN Yueshun; LU Yiyan; LI Houxiang; ZENG Sanhai

    2007-01-01

    The influence of reinforced bar corrosion on the bond degradation in lightweight concrete was studied. Accelerated constant current corrosion tests were performed on lightweight reinforced concrete samples, and the influential factors, such as protective layer thickness, reinforced bar diameter and corrosive level were investigated. The constant current step method was used to measure the electric resistance of the concrete protective cover, which was used to characterize the corrosion level of the rebar. Experimental results indicated that the corrosive resistance increased with increasing the cover dimension and decreasing the reinforced bar diameter, and the rate of decrease in the specimen impedance after cracking depended on the cover dimension. A new medium was offered for the further research on the performance degradation of corrosion lightweight concrete.

  2. Impact of biofouling on corrosion resistance of reinforced concrete

    Digital Repository Service at National Institute of Oceanography (India)

    Patil, B.T.; Gajendragad, M.R.; Ranganna, G.; Wagh, A.B.; Sudhakaran, T.

    the structure from deterioration; a nonuniform deposit can lead to severe localized pitting corrosion. To study this cylindrical reinforced concrete electrodes were exposed to seawater. They were periodically removed and examined for the presence of fouling...

  3. Seismic fragility of a reinforced concrete structure

    Energy Technology Data Exchange (ETDEWEB)

    Kurmann, Davide [Axpo Power AG, Baden (Switzerland); Proske, Dirk [Axpo Power AG, Doettingen (Switzerland); Cervenka, Jan [Cervenka Consulting, Prague (Czech Republic)

    2013-05-15

    Structures can be exposed to seismic loading. For structures of major importance, extreme seismic loadings have to be considered. The proof of safety for such loadings requires sophisticated analysis. This paper introduces an analysis method which of course still includes simplifications, but yields to a far more realistic estimation of the seismic load bearing capacity of reinforced concrete structures compared to common methods. It is based on the development of pushover curves and the application of time-histories for the dynamic model to a representative harmonic oscillator. Dynamic parameters of the oscillator, such as modal mass and damping are computed using a soil-structure-interaction analysis. Based on the pushover-curve nonlinear force-deformation-capacities are applied to the oscillator including hysteresis behaviour characteristics. The oscillator is then exposed to time-histories of several earthquakes. Based on this computation the ductility is computed. The ductility can be scaled based upon the scaling of the time-histories. Since both, the uncertainty of the earthquake by using different timehistories and the uncertainty of the structure by using characteristic and mean material values, are considered, the uncertainty of the structure under seismic loading can be explicitly represented by a fragility. (orig.)

  4. Analysis of reinforced concrete building according to the EC 8

    OpenAIRE

    Dimec, Andrej

    2009-01-01

    In the Thesis the analysis and the software based design of the six-storey reinforced concrete wall building according to the European Standard Eurocode is presented. The structural system of the building consists of reinforced concrete walls. First the calculation of the self weight, variable actions, snow and the wind loads has been examined. The major part of the thesis deals with seismic analysis, which was performed by the modal analysis and simplified non-linear seismic a...

  5. Design of macro-synthetic fibre reinforced concrete pipes

    OpenAIRE

    Fuente, Albert de la; Escariz, Renata Campos; Figueiredo,Antonio Domingues de; Aguado, Antonio

    2013-01-01

    This paper presents an experimental campaign in which concrete pipes were manufactured using plastic fibres as the sole reinforcement material. In this regard, it has been demonstrated that the use of plastic fibres is compatible with pipe production systems, and that, when subjected to the crushing test (CT), plastic fibre reinforced pipes yield strength classes that are attractive in terms of the growth of this material in the concrete pipe industry. Moreover, the results obtained from b...

  6. Reinforcement of the concrete base slab of the ATLAS cavern

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    Photo 02: UX15 cavern, preparation for concreting of base slab first lift. Photo 05: UX15 cavern, placing of reinforcement for base slab first lift. Photo 07: UX15 cavern, preparation for concreting of base slab first lift. Photo 09: UX15 cavern, placing of reinforcement for base slab first lift. Photo 10: UX15 cavern, view into PX14 shaft above. Photo 12: UX15 cavern, temporary access platform of RB16 tunnel. Photo 15: UJ17 chamber, invert excavation.

  7. Stochastic Models for Chloride-Initiated Corrosion in Reinforced Concrete

    DEFF Research Database (Denmark)

    Engelund, Svend; Sørensen, John Dalsgaard

    Corrosion of the reinforcement in concrete structures can lead to a substantial decrease of the load-bearing capacity. One mode of corrosion initiation is when the chloride content around the reinforcement exceeds a threshold value. In the present paper a statistical model is developed by which t...... the chloride content in a 1reinforced concrete structure can be predicted. The model parameters are estimated on the basis of measurements. The distribution of the time to initiation of corrosion is estimated by FORMISORM-analysis.......Corrosion of the reinforcement in concrete structures can lead to a substantial decrease of the load-bearing capacity. One mode of corrosion initiation is when the chloride content around the reinforcement exceeds a threshold value. In the present paper a statistical model is developed by which...

  8. Reinforced concrete bridges: effects due to corrosion and concrete young modulus variation

    Directory of Open Access Journals (Sweden)

    P. T. C. Mendes

    Full Text Available Most of the Brazilian bridges of federal road network are made of reinforced concrete and are more than 30 years old, with little information about the mechanical properties of their constitutive materials. Along the service life of these bridges much modification occurred on vehicles load and geometry and in design standard. Many of them show signs of concrete and steel deterioration and their stability conditions are unknown. With the aim of contributing to the structural evaluation of reinforced concrete bridges it was decided to analyze the stresses in reinforced concrete bridge sections to verify the effects due to reinforcement corrosion and variation of the concrete Young modulus on the stress distribution regarding several load patterns and cracking effects in a representative bridge of the Brazilian road network with different longitudinal reinforcement taxes and two concrete Young modulus, Ec and 0.5Ec, and with different percentage of reinforcement corrosion. The analysis considered two finite element models: frame and shell elements as well as solid elements. The results indicate that these variation effects are more significant in reinforcement bars than in concrete.

  9. Prevention of reinforcement corrosion by hydrophobic treatment of concrete

    NARCIS (Netherlands)

    Polder, R.B.; Borsje, H.; Vries, H. de

    2001-01-01

    Corrosion of reinforcement in concrete bridge decks may occur due to penetration of de-icing salts, even in the presence of an asphalt overlay. This paper reports a laboratory study into additional protection of concrete by hydrophobic treatment. It was found that hydrophobic treatment strongly redu

  10. Corrosion protection of reinforcement by hydrophobic treatment of concrete

    NARCIS (Netherlands)

    Polder, R.B.; Vries, H. de

    1999-01-01

    Penetration of de-icing salts into concrete bridge decks may cause corrosion of reinforcement. Hydrophobic treatment of concrete was studied as additional protection. It was shown that hydrophobic treatment strongly reduces chloride ingress, during semi-permanent contact and in wetting/drying situat

  11. Cracking in reinforced concrete structures due to imposed deformations

    Energy Technology Data Exchange (ETDEWEB)

    Nagy, A.

    1997-04-01

    This thesis is concerned with modeling of the cracking process in reinforced concrete due to imposed deformations. Cracking is investigated both at early ages, during hydration, and at mature age when the final properties of the concrete are reached. One of the most important material characteristics of the concrete at early ages, the Young`s modulus is determined by means of a dynamic method called the resonance frequency method. 40 refs

  12. External reinforcing of fiber concrete constructions by carbon fiber tapes

    OpenAIRE

    S.V. Klyuyev; Yu.V. Guryanov

    2013-01-01

    Strengthening the concrete and reinforced concrete structures with carbon fiber tapes is very actively applied in Europe nowadays. In Russia composites based on carbon fiber have also widely spread recently. The main advantages of these materials for strengthening structures are its high specific strength (strength-weight ratio) and strength-to-density ratio.Experimental studies on strengthening and restoration of the constructions were held. Flexible fiber concrete constructions based on man...

  13. Shear Reinforcement Requirements for High-Strength Concrete Bridge Girders

    OpenAIRE

    Ramirez, J. A.; Aguilar, Gerardo

    2005-01-01

    A research program was conducted on the shear strength of high-strength concrete members. The objective was to evaluate the shear behavior and strength of concrete bridge members with compressive strengths in the range of 10 000 to 15 000 psi. The goal was to determine if the current minimum amount of shear reinforcement together with maximum spacing limits in the 2004 AASHTO LRFD Specifications, and the upper limit on the nominal shear strength were applicable to concrete compressive strengt...

  14. Material and Flexural Properties of Fiber-reinforced Rubber Concrete

    Science.gov (United States)

    Helminger, Nicholas P.

    The purpose of this research is to determine the material properties of rubber concrete with the addition of fibers, and to determine optimal mixture dosages of rubber and fiber in concrete for structural applications. Fiber-reinforced concrete and rubberized concrete have been researched separately extensively, but this research intends to combine both rubber and fiber in a concrete matrix in order to create a composite material, fiber-reinforced rubber concrete (FRRC). Sustainability has long been important in engineering design, but much of the previous research performed on sustainable concrete does not result in a material that can be used for practical purposes. While still achieving a material that can be used for structural applications, economical considerations were given when choosing the proportions and types of constituents in the concrete mix. Concrete mixtures were designed, placed, and tested in accordance with common procedures and standards, with an emphasis on practicality. Properties that were investigated include compressive strength, tensile strength, modulus of elasticity, toughness, and ductility. The basis for determining the optimal concrete mixture is one that is economical, practical, and exhibits ductile properties with a significant strength. Results show that increasing percentages of rubber tend to decrease workability, unit weight, compressive strength, split tensile strength, and modulus of elasticity while the toughness is increased. The addition of steel needle fibers to rubber concrete increases unit weight, compressive strength, split tensile strength, modulus of elasticity, toughness, and ductility of the composite material.

  15. Behaviour of concrete beams reinforced withFRP prestressed concrete prisms

    Science.gov (United States)

    Svecova, Dagmar

    The use of fibre reinforced plastics (FRP) to reinforce concrete is gaining acceptance. However, due to the relatively low modulus of FRP, in comparison to steel, such structures may, if sufficient amount of reinforcement is not used, suffer from large deformations and wide cracks. FRP is generally more suited for prestressing. Since it is not feasible to prestress all concrete structures to eliminate the large deflections of FRP reinforced concrete flexural members, researchers are focusing on other strategies. A simple method for avoiding excessive deflections is to provide sufficiently high amount of FRP reinforcement to limit its stress (strain) to acceptable levels under service loads. This approach will not be able to take advantage of the high strength of FRP and will be generally uneconomical. The current investigation focuses on the feasibility of an alternative strategy. This thesis deals with the flexural and shear behaviour of concrete beams reinforced with FRP prestressed concrete prisms. FRP prestressed concrete prisms (PCP) are new reinforcing bars, made by pretensioning FRP and embedding it in high strength grout/concrete. The purpose of the research is to investigate the feasibility of using such pretensioned rebars, and their effect on the flexural and shear behaviour of reinforced concrete beams over the entire loading range. Due to the prestress in the prisms, deflection of concrete beams reinforced with this product is substantially reduced, and is comparable to similarly steel reinforced beams. The thesis comprises both theoretical and experimental investigations. In the experimental part, nine beams reinforced with FRP prestressed concrete prisms, and two companion beams, one steel and one FRP reinforced were tested. All the beams were designed to carry the same ultimate moment. Excellent flexural and shear behaviour of beams reinforced with higher prestressed prisms is reported. When comparing deflections of three beams designed to have the

  16. Evaluation of Shear Resisting Capacity of a Prestressed Concrete Containment Building with Steel or Polyamide Fiber Reinforcement

    Energy Technology Data Exchange (ETDEWEB)

    Choun, Youngsun; Park, Junhee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    Conventional reinforced concrete (RC) members generally show a rapid deterioration in shear resisting mechanisms under a reversed cyclic load. However, the use of high-performance fiber-reinforced cement composites provides excellent damage tolerance under large displacement reversals compared with regular concrete. Previous experimental studies have indicated that the use of fibers in conventional RC can enhance the structural and functional performance of prestressed concrete containment buildings (PCCBs) in nuclear power plants. This study evaluates the shear resisting capacity for a PCCB constructed using steel fiber reinforced concrete (SFRC) or polyamide fiber reinforced concrete (PFRC). The effects of steel and polyamide fibers on the shear performance of a PCCB were investigated. It was revealed that steel fibers are more effective to enhance the shear resisting capacity of a PCCB than polyamide fibers. The ductility and energy dissipation increase significantly in fiber reinforced PCCBs.

  17. Reinforcement of concrete structures by fiberglass rods

    Directory of Open Access Journals (Sweden)

    Avdeeva Arina

    2016-01-01

    Full Text Available In this article we introduced conducted experiments to determine the basic characteristics of composite reinforcement fiberglass reinforcement on the example of the same diameter, but with a different number of rovings. We have established strength along the reinforcing fiber and the corresponding class of the steel reinforcement.

  18. Shear strength of non-shear reinforced concrete elements

    DEFF Research Database (Denmark)

    Hoang, Cao linh

    1997-01-01

    The report deals with the shear strength of statically indeterminate reinforced concrete beams without shear reinforcement. Solutions for a number of beams with different load and support conditions have been derived by means of the crack sliding model developed by Jin- Ping Zhang.This model...

  19. A New Type Anticorrosion Coating for Ocean Reinforced Concrete Structures

    Institute of Scientific and Technical Information of China (English)

    CHENG Qi; GENG Guisheng; LUO Feng; WU Sanyu; ZHAO Dalin

    2000-01-01

    Corrosion of reinforced concrete structures is a serious problem in ocean engineering. As an orientation of study, anticorrosion coating technique is developed and widely applied, but many problems need to be solved. LSW-2 type anticorrosion coating for maritime reinforced concrete structures is charac lerized by sea water resistance, salt fog resistance, moisture and heat resistance as well as impermeability to chlorions. The new type coating can be applied to wet concrete surface by conventional construction lechnique. It is a breakthrough in solving the above-mentioned problem. The paper mainly introduces the test results, the property indices, coating procedure, construction technique and economic benefit of the coating.

  20. Optimization Design and Application of Underground Reinforced Concrete Bifurcation Pipe

    Directory of Open Access Journals (Sweden)

    Chao Su

    2015-01-01

    Full Text Available Underground reinforced concrete bifurcation pipe is an important part of conveyance structure. During construction, the workload of excavation and concrete pouring can be significantly decreased according to optimized pipe structure, and the engineering quality can be improved. This paper presents an optimization mathematical model of underground reinforced concrete bifurcation pipe structure according to real working status of several common pipe structures from real cases. Then, an optimization design system was developed based on Particle Swarm Optimization algorithm. Furthermore, take the bifurcation pipe of one hydropower station as an example: optimization analysis was conducted, and accuracy and stability of the optimization design system were verified successfully.

  1. Design Basis for Fibre Reinforced Concrete (FRC) Pavements

    DEFF Research Database (Denmark)

    Bendixen, Søren; Stang, Henrik

    1996-01-01

    -crack opening relationship can beused to descibe the properties of fibre reinforced concrete (FRC) intension and how the stress-crack opening relationship can beapplied in a simple design scheme for pavements. The projectincludes development of design tools, experiments to determine thestress-crack opening......The paper summarises a Ph.D. project on development of a new design basis for fibre reinforced concrete ground slabs. The stress-crack openingrelationship is a well know basic material property of theso-called fictitious crack model for concrete. In the presentstudy it is shown how the stress...

  2. DAMAGE LOCATION DUE TO CORROSION IN REINFORCED CONCRETE STRUCTURES

    Institute of Scientific and Technical Information of China (English)

    WUJin; ChengJi-xin; LUMing-sheng

    2004-01-01

    An investigation on damage location due to the corrosion in reinforced concrete structures is conducted. The frequency change square ratio is used as a parameter for the damage. It is theoretically verified that the parameter is a function of the damage location. Experimental results of the corrosion in reinforced concrete structures show that the predicted damage location is in agreement with the real damage location. The modal parameters are used to detect the damages in structural concrete elements, and so they are useful for structural appraisal.

  3. Experiment and calculation of reinforced concrete at elevated temperatures

    CERN Document Server

    Guo, Zhenhai

    2011-01-01

    Concrete as a construction material goes through both physical and chemical changes under extreme elevated temperatures. As one of the most widely used building materials, it is important that both engineers and architects are able to understand and predict its behavior in under extreme heat conditions. Brief and readable, this book provides the tools and techniques to properly analysis the effects of high temperature of reinforced concrete which will lead to more stable, safer structures. Based on years of the author's research, Reinforced Concrete at Elevated Temperatures four par

  4. Diagonal Cracking and Shear Strength of Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Zhang, Jin-Ping

    1997-01-01

    found by the usual plastic theory, a physical explanation is given for this phenomenon and a way to estimate the shear capacity of reinforced concrete beams, based on the theory of plasticity, is described. The theoretical calculations are shown to be in fairly good agreement with test results from......The shear failure of non-shear-reinforced concrete beams with normal shear span ratios is observed to be governed in general by the formation of a critical diagonal crack. Under the hypothesis that the cracking of concrete introduces potential yield lines which may be more dangerous than the ones...

  5. Shear Capacity of Steel and Polymer Fibre Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Kragh-Poulsen, Jens C.; Hoang, Cao Linh; Goltermann, Per

    2011-01-01

    This paper deals with the application of a plasticity model for shear strength estimation of fibre reinforced concrete beams without stirrups. When using plastic theory to shear problems in structural concrete, the so-called effective strengths are introduced, usually determined by calibrating...... the plastic solutions with tests. This approach is, however, problematic when dealing with fibre reinforced concrete (FRC), as the effective strengths depend also on the type and the amount of fibres. In this paper, it is suggested that the effective tensile strength of FRC can be determined on the basis...

  6. Strength Evaluation of Steel-Nylon Hybrid Fibre Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Maniram Kumar

    2014-07-01

    Full Text Available When fibres like steel, glass, polypropylene, nylon, carbon, aramid, polyester, jute, etc are mixed with concrete known as fibre reinforced concrete. To overcome the deficiencies of concrete; fibres are added to improve the performance of concrete. In this research hybrid reinforced concrete is made by using steel and nylon 6 fibres. The inclusion of both steel and nylon 6 fibres are used in order to combine the benefits of both fibers; structural improvements provided by steel fibers and the resistance to plastic shrinkage improvements provided by nylon fibers. So the aim of this project is to investigate the mechanical properties (compressive strength, flexure strength and split tensile strength of hybrid fiber reinforced concrete under compression, flexure & tension. The total volume of fibre was taken 0.75 % of total volume of concrete. In this experimental work, four different concrete mix proportions were casted with fibres and one mix without fibres. Four different mix combinations of steel- nylon 6 fibres were 100-00%, 75-25%, 50-50% and 25-75%. Superplasticizer was used in all mixes to make concrete more workable. The results shown that compressive, split tensile and flexural strength of hybrid fibre reinforced concrete increase by increasing quantity of steel and nylon 6 fibres. The increase in compressive and tensile strength due to incorporation of steel fibre is greater than that of using nylon fibre. For the nylon 6 fibres, adding more fibres into the concrete has a limited improvement on splitting tensile strength. Inclusion of nylon 6 fibres along with steel fibres results in considerable improvement in flexural strength as compared to solo steel fibre.

  7. Experimental analysis of reinforced concrete beams strengthened in bending with carbon fiber reinforced polymer

    Directory of Open Access Journals (Sweden)

    M. M. VIEIRA

    Full Text Available The use of carbon fiber reinforced polymer (CFRP has been widely used for the reinforcement of concrete structures due to its practicality and versatility in application, low weight, high tensile strength and corrosion resistance. Some construction companies use CFRP in flexural strengthening of reinforced concrete beams, but without anchor systems. Therefore, the aim of this study is analyze, through an experimental program, the structural behavior of reinforced concrete beams flexural strengthened by CFRP without anchor fibers, varying steel reinforcement and the amount of carbon fibers reinforcement layers. Thus, two groups of reinforced concrete beams were produced with the same geometric feature but with different steel reinforcement. Each group had five beams: one that is not reinforced with CFRP (reference and other reinforced with two, three, four and five layers of carbon fibers. Beams were designed using a computational routine developed in MAPLE software and subsequently tested in 4-point points flexural test up to collapse. Experimental tests have confirmed the effectiveness of the reinforcement, ratifying that beams collapse at higher loads and lower deformation as the amount of fibers in the reinforcing layers increased. However, the increase in the number of layers did not provide a significant increase in the performance of strengthened beams, indicating that it was not possible to take full advantage of strengthening applied due to the occurrence of premature failure mode in the strengthened beams for pullout of the cover that could have been avoided through the use of a suitable anchoring system for CFRP.

  8. Inspection of reinforcement concrete structures with active infrared thermography

    Science.gov (United States)

    Szymanik, Barbara; Chady, Tomasz; Frankowski, Paweł

    2017-02-01

    In this article the reinforced concrete non-destructive evaluation using active thermography is discussed. There are several aspects of possible non-destructive testing of mentioned structures. One of them is the detection and assessment of the reinforcement itself. In case of active thermography, the external energy source has to be used to induce the thermal response of the inspected specimen. Here, authors propose two different techniques: microwave heating and induction heating. In this article authors will present several experimental results which will allow to compare mentioned two techniques of heating. suitability of each one to assess the reinforced concrete by using the active thermography will be discussed.

  9. Stochastic Models for Chloride-Initiated Corrosion in Reinforced Concrete

    DEFF Research Database (Denmark)

    Engelund, S.; Sørensen, John Dalsgaard

    1996-01-01

    Corrosion of the reinforcement in concrete structures can lead to a substantial decrease of the load-bearing capacity. One mode of corrosion initiation is when the chloride content around the reinforcement exceeds a threshold value. In the present paper a statistical model is developed by which...... the chloride content in a reinforced concrete structure can be predicted. The model parameters are estimated on the basis of measurements. The distribution of the time to initiation of corrosion is estimated by FORM/SORM-analysis....

  10. Monitoring Corrosion of Steel Bars in Reinforced Concrete Structures

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar Verma

    2014-01-01

    Full Text Available Corrosion of steel bars embedded in reinforced concrete (RC structures reduces the service life and durability of structures causing early failure of structure, which costs significantly for inspection and maintenance of deteriorating structures. Hence, monitoring of reinforcement corrosion is of significant importance for preventing premature failure of structures. This paper attempts to present the importance of monitoring reinforcement corrosion and describes the different methods for evaluating the corrosion state of RC structures, especially hal-cell potential (HCP method. This paper also presents few techniques to protect concrete from corrosion.

  11. Monitoring corrosion of steel bars in reinforced concrete structures.

    Science.gov (United States)

    Verma, Sanjeev Kumar; Bhadauria, Sudhir Singh; Akhtar, Saleem

    2014-01-01

    Corrosion of steel bars embedded in reinforced concrete (RC) structures reduces the service life and durability of structures causing early failure of structure, which costs significantly for inspection and maintenance of deteriorating structures. Hence, monitoring of reinforcement corrosion is of significant importance for preventing premature failure of structures. This paper attempts to present the importance of monitoring reinforcement corrosion and describes the different methods for evaluating the corrosion state of RC structures, especially hal-cell potential (HCP) method. This paper also presents few techniques to protect concrete from corrosion.

  12. IMPACT OF CHLORIDES ON REINFORCED CONCRETE: SIMULATION OF ITS INGRESS IN CONCRETE

    Directory of Open Access Journals (Sweden)

    S. Leonovich

    2012-01-01

    Full Text Available The paper presents a model for evaluation of environmental conditions that influence on reinforced highway structures. The models is applied for calculation of chloride ingress in concrete structures while using de-icing salt.

  13. IMPACT OF CHLORIDES ON REINFORCED CONCRETE: SIMULATION OF ITS INGRESS IN CONCRETE

    OpenAIRE

    S. Leonovich; A. Prasol

    2012-01-01

    The paper presents a model for evaluation of environmental conditions that influence on reinforced highway structures. The models is applied for calculation of chloride ingress in concrete structures while using de-icing salt.

  14. Properties of Fiber Reinforced Polymer Concrete

    Directory of Open Access Journals (Sweden)

    Marinela Bărbuţă

    2008-01-01

    Full Text Available Polymer concrete is a composite material realized with resin and aggregates. In the present study the epoxy resin was used for binding the aggregates. In the composition were introduced near the fly ash, used as filler, the cellulose fibers. The mechanical characteristics such as compressive strength, flexural strength and split tensile strength of polymer concrete with fibers were investigated. The fiber percentage was constant, the epoxy resin and the filler dosages were varied. The cellulose fiber had not improved the mechanical characteristics of the polymer concrete in comparison to that of polymer concrete without cellulose fibers.

  15. STRAIN HARDENING PROPERTIES OF STEEL FIBRE REINFORCED LATEX CONCRETE COMPOSITE

    Directory of Open Access Journals (Sweden)

    V.M. Sounthararajan

    2013-04-01

    Full Text Available Steel fibre addition in concrete possesses high merits in terms of achieving homogeneity and tensile strength properties. Polymeric addition in concrete has high advantages in terms of pore fillingeffect and subsequent increase in durability index. The combined addition of steel and polymeric latex additions in concrete leads to increased strength, durability, toughness, resistance to cracking and crack propagation. Studies were conducted in the present study to analyse the properties of concrete that can be further improved with the addition of polymer styrene butadiene rubber emulsion (SBR along with steel fibres. In this research analysis, styrene-butadiene rubber (SBR latex as a polymeric admixture was used in steel fibre reinforced concrete. The effect of curing conditions on the strength gain properties of composite steel fibre latex matrix on the compressive, flexural strength, and split tensile test of polymermodified steel fibre reinforced concrete (PSFC concrete was examined. Including SBR latex at a certain % of binder in the PSFC concrete improves the bonds within the cement matrix and steel fibres (SF. This is due to the SBR films formed in the matrix. By the comparison of properties of SFC and PSFC, it can be shown that a tremendous increase in compressive strength when 4% and 8% SBR is added along with 0.75% and 1.5% SF. The increase in flexural strength was noticed and post cracking ductility is imparted to concrete.

  16. Acoustic emission characteristics on microscopic damage behavior of carbon fiber sheet reinforced concrete

    Science.gov (United States)

    Lee, Jin Kyung; Lee, Joon Hyun

    2002-05-01

    In this study, a three-point bend test has been carried out to understand the damage progress and the micro-failure mechanism of carbon fiber sheet (CFS) reinforced concretes. For these purposes, four kinds of specimens were used; unreinforced concrete, steel bar reinforced concrete, CFS reinforced concrete, and concrete reinforced by both steel bar and CFS. Acoustic Emission (AE) technique was used to evaluate the characteristics of damage progress and the failure mechanism of the specimens.

  17. Corrosion inhibiting repair and rehabilitation treatment process for reinforced concrete structures

    OpenAIRE

    1994-01-01

    A repair and rehabilitation treatment process for reinforced concrete structures involves the removal of concrete from above rebar or other metal reinforcement material in the concrete structure. After removal of concrete, the metal reinforcement materials are saturated with corrosion inhibiting agents. Saturation is best achieved by multiple spray applications of the corrosion inhibitor. The cavity in the concrete structure with the treated rebar or other metal reinforcement materials is the...

  18. STUDIES OF DURABILITY ASPECTS OF FIBRE REINFORCED CONCRETE

    Directory of Open Access Journals (Sweden)

    D. MARUTHACHALAM

    2012-02-01

    Full Text Available This paper presents a detailed experimental study on sulphate attack, depth of carbonation, alkalinity measurement on fibre reinforced concrete at ages 28 days, 56 days, and 90 days. The main variable investigated in this study is variation of fibre dosage of 0.1%, 0.2%, and 0.3%. The concrete produced by the addition of fly ash and metakaolin as a partial replacement of cement. The compressive strength, weight loss and hardness of concrete were studied. Test results indicate that use of fibre in concrete has improved performance of concrete. A simple regression equation has been proposed to study the behaviour of concrete under sulphate attack, depth of carbonation.

  19. Structural Behavior of Concrete Beams Reinforced with Basalt Fiber Reinforced Polymer (BFRP) Bars

    Science.gov (United States)

    Ovitigala, Thilan

    The main challenge for civil engineers is to provide sustainable, environmentally friendly and financially feasible structures to the society. Finding new materials such as fiber reinforced polymer (FRP) material that can fulfill the above requirements is a must. FRP material was expensive and it was limited to niche markets such as space shuttles and air industry in the 1960s. Over the time, it became cheaper and spread to other industries such as sporting goods in the 1980-1990, and then towards the infrastructure industry. Design and construction guidelines are available for carbon fiber reinforced polymer (CFRP), aramid fiber reinforced polymer (AFRP) and glass fiber reinforced polymer (GFRP) and they are currently used in structural applications. Since FRP is linear elastic brittle material, design guidelines for the steel reinforcement are not valid for FRP materials. Corrosion of steel reinforcement affects the durability of the concrete structures. FRP reinforcement is identified as an alternative to steel reinforcement in corrosive environments. Although basalt fiber reinforced polymer (BFRP) has many advantages over other FRP materials, but limited studies have been done. These studies didn't include larger BFRP bar diameters that are mostly used in practice. Therefore, larger beam sizes with larger BFRP reinforcement bar diameters are needed to investigate the flexural and shear behavior of BFRP reinforced concrete beams. Also, shear behavior of BFRP reinforced concrete beams was not yet studied. Experimental testing of mechanical properties and bond strength of BFRP bars and flexural and shear behavior of BFRP reinforced concrete beams are needed to include BFRP reinforcement bars in the design codes. This study mainly focuses on the use of BFRP bars as internal reinforcement. The test results of the mechanical properties of BFRP reinforcement bars, the bond strength of BFRP reinforcement bars, and the flexural and shear behavior of concrete beams

  20. Acrylic Rubber Latex in Ferrocement for Strengthening Reinforced Concrete Beams

    Directory of Open Access Journals (Sweden)

    D. R. Kumar

    2010-01-01

    Full Text Available Problem statement: In India, the early deterioration of reinforced concrete structures has become a big social problem in recent years. An essential research is needed for the development of effective repair materials and their execution systems comes to an important issue from the viewpoint of the longevity of infrastructures at present. Ferrocement laminates are introduced to enhance the overall performance of Reinforced Concrete (RC structures and these days the use of it is a promising technology for increasing the flexural strength of deficient reinforced concrete members. Approach: The repair system aims to provide quantitative repair enhancement as well as extending the life of deteriorated concrete members. This research in particular inspired the initiation of the present work which aimed to develop a material with unique properties and a very wide range of practical applications. The mechanical properties of mortar through difference in polymer content with Acrilic Latex by ferrocement among three different volume fractions of mesh reinforcement were studied. Following the encouraging progress made in the formulation and evaluation of the polymer modified repair mortar, tests were carried out involving the application of the reinforced repair material to the soffit of the reinforced concrete beams of 3 m length. Results: The levels of damage of the original beams prior to repair did not affect the ultimate load of the strengthened beams tested. The performance of the strengthened beams was compared to the control beams with respect to cracking, deflection and ultimate strength which confirm preeminent results. Conclusion: This accomplished the fact that acrylic rubber latex modified ferrocement is a doable alternative strengthening component for the rehabilitation of reinforced concrete structures. Further developments in these systems will create dramatic improvement into the field of rehabilitation of old privileged structures.

  1. Behavior and Performance of GFRP Reinforced Concrete Columns with Various Types of Stirrups

    OpenAIRE

    Woraphot Prachasaree; Sitthichai Piriyakootorn; Athawit Sangsrijun; Suchart Limkatanyu

    2015-01-01

    Fiber reinforced polymer (FRP) composites are gaining acceptance in concrete structural applications due to their high ratio of strength/stiffness to self-weight and corrosion resistance. This study focused on the structural behavior and the performance of concrete columns internally reinforced with glass fiber reinforced plastic (GFRP) rebars. Twelve series of concrete columns with varied longitudinal reinforcement, cross section, concrete cover, and type of lateral reinforcement were tested...

  2. Evaluating plastic shrinkage and permeability of polypropylene fiber reinforced concrete

    Directory of Open Access Journals (Sweden)

    G.M. Sadiqul Islam

    2016-12-01

    Full Text Available Plastic concrete is susceptible to develop cracks due to shrinkage in dry and windy conditions. Addition of fibers could reduce propagation of this crack. On the other hand, permeability determines the durability properties of concrete. This study evaluated strength, plastic shrinkage and permeability (gas and water of concrete incorporating ‘polypropylene’ fiber (aspect ratio 300 in various proportions (viz. 0.10%, 0.15%, 0.2%, 0.25% and 0.3% by volume of concrete. Plane concrete samples were also prepared and tested for reference purpose. Inclusion of 0.1% fiber gave minor reduction (2% in compressive strength while the tensile strength increased by 39% with same fiber content compared to the plain concrete. A significant reduction in crack generation, appearance period of first crack and crack area between plane concrete and fiber reinforced concretes was found. The experimental result with inclusion of 0.1–0.3% fiber in concrete indicated that plastic shrinkage cracks were reduced by 50–99% compared to the plain concrete. For reference concrete (without fiber, test within the high temperature and controlled humidity chamber gave higher crack width than the acceptable limit (3 mm specified by the ACI 224. With the inclusion of 0.1% fiber reduced the crack width down to 1 mm and the trend was continued with the addition of more fibers. However, results showed that with the addition of polypropylene fiber both water and gas permeability coefficient was increased. Therefore, it is concluded that the fiber reinforced concrete would work better for plastic shrinkage susceptible structural elements (flat elements such as slab; however, it requires careful judgement while applying to a water retaining structures.

  3. In-plane shear test of fibre reinforced concrete panels

    DEFF Research Database (Denmark)

    Solgaard, Anders Ole Stubbe; Stang, Henrik; Goltermann, Per

    2008-01-01

    contributes to the investigation of fibers as reinforcement in panels with experimental results and a consistent approach to material characterization and modeling. The proposed model draws on elements from the classical yield line theory of rigid, perfectly plastic materials and the theory of fracture......The present paper concerns the investigation of polymer Fiber Reinforced Concrete (FRC) panels subjected to in-plane shear. The use of fibers as primary reinforcement in panels is a new application of fiber reinforcement, hence test methods, design bases and models are lacking. This paper...

  4. Application of a Reinforced Self-Compacting Concrete Jacket in Damaged Reinforced Concrete Beams under Monotonic and Repeated Loading

    Directory of Open Access Journals (Sweden)

    Constantin E. Chalioris

    2013-01-01

    Full Text Available This paper presents the findings of an experimental study on the application of a reinforced self-compacting concrete jacketing technique in damaged reinforced concrete beams. Test results of 12 specimens subjected to monotonic loading up to failure or under repeated loading steps prior to total failure are included. First, 6 beams were designed to be shear dominated, constructed by commonly used concrete, were initially tested, damaged, and failed in a brittle manner. Afterwards, the shear-damaged beams were retrofitted using a self-compacting concrete U-formed jacket that consisted of small diameter steel bars and U-formed stirrups in order to increase their shear resistance and potentially to alter their initially observed shear response to a more ductile one. The jacketed beams were retested under the same loading. Test results indicated that the application of reinforced self-compacting concrete jacketing in damaged reinforced concrete beams is a promising rehabilitation technique. All the jacketed beams showed enhanced overall structural response and 35% to 50% increased load bearing capacities. The ultimate shear load of the jacketed beams varied from 39.7 to 42.0 kN, whereas the capacity of the original beams was approximately 30% lower. Further, all the retrofitted specimens exhibited typical flexural response with high values of deflection ductility.

  5. Crack widths in concrete with fibers and main reinforcement

    DEFF Research Database (Denmark)

    Christensen, Frede; Ulfkjær, Jens Peder; Brincker, Rune

    the ductility of the fiber reinforced concrete (FRC) is set up and experimental work is conducted in order to verify the crack width model. The ductility of the FRC is taken into account by using the stress crack width relation. The constitutive model for the FRC is based on the idea that the initial part......The main object of the research work presented in this paper is to establish design tools for concrete structures where main reinforcement is combined with addition of short discrete steel fibers. The work is concerned with calculating and measuring crack widths in structural elements subjected...... to bending load. Thus, the aim of the work is to enable engineers to calculate crack widths for flexural concrete members and analyze how different combinations of amounts of fibers and amounts of main reinforcement can meet a given maximum crack width requirement. A mathematical model including...

  6. Analysis of cracking in reinforced concrete using accelerated tests

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Q.T.; Berthaud, Y. [Univ Paris 06, CNRS, ENSC, LMT, F-94235 Cachan (France); Care, S [CNRS, ENPC, LCPC, Inst Navier, LMSGC, F-77420 Champs Sur Marne (France); Millard, A. [CEA, DEN/DM2S/SEMT/LM2S, F-91191 Gif Sur Yvette (France)

    2007-02-15

    We present in this Note an experimental study-in a laboratory setup-of the mechanical effect (cracking of concrete) of corrosion on plates made of reinforced concrete. Due to the geometry it is possible to use digital image correlation to follow the evolution of strains induced by the corrosion of reinforcement. The corrosion is accelerated by the imposition of current density. Even if the representativeness of this test is still discussed, it allows one to record the entire strain history. The kinetics of cracking has been obtained and compared to a very simple model in which the increase of the corroded layer is modelled by a fictitious thermal load, the reinforcement remaining elastic and the concrete being damageable. (authors)

  7. Finite element model of reinforcement corrosion in concrete

    Institute of Scientific and Technical Information of China (English)

    Jin-xia XU; Lin-hua JIANG; Qi WANG

    2009-01-01

    A nonlinear finite element model (FEM) of the corrosion of steel reinforcement in concrete has been successfully developed on the basis of mathematical analysis of the electrochemical process of steel corrosion in concrete. The influences of the area ratio and the Tafel constants of the anode and cathode on the potential and corrosion current density have been examined with the model. It has been found that the finite element calculation is more suitable for assessing the corrosion condition of steel reinforcement than ordinary electrochemical techniques due to the fact that FEM can obtain the distributions of potential and corrosion current density on the steel surface. In addition, the local corrosion of steel reinforcement in concrete is strengthened with the decrease of both the area ratio and the Tafel constants. These results provide valuable information to the researchers who investigate steel corrosion.

  8. Dynamic behavior of reinforced concrete frame structure during construction

    Institute of Scientific and Technical Information of China (English)

    TIAN Ming-ge; YI Wei-jian

    2008-01-01

    The effects of concrete's time-variant elastic modulus, casting structural components, assembling temporary shoring framework system, and shock by operating construction equipment on dynamic behavior of the reinforced concrete frame structure during construction were investigated. The dynamic tests of an eight-storey reinforced concrete frame structure during full-scaled stages of the sixth storey construction cycle were carried out by ambient vibration. Natural frequencies, corresponding mode shapes and damping ratio were determined by power spectrum processing the tested signal data in frequency domain. The changes of frequencies, mode shapes and damping ratios at different construction stages were given. The results show that natural frequencies and modal damping ratios reach the maximum at stage of casting fresh concrete, especially for higher modes. Modal damping ratios at each construction stage are less than 5% of those during usage.

  9. Flexural Strength and Behavior of Polypropylene Fiber Reinforced Concrete Beams

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The strength and deformation characteristics of polypropylene fiber reinforced concrete (PFRC) beams were investigated by four-point bending procedures in this paper.Two kinds of polypropylene fibers with different fiber contents (0.2%, 0.5%, 1.0% and 1.5%) by volume were used in the beam, which measured 100×100 mm with a span of 300 mm.It was found that the strength of the reinforced concrete beams was significantly decreased,whereas the flexural toughness was improved,compared to those unreinforced concrete beams.Geometry properties and volume contents of polypropylene fiber were considered to be important factors for improving the flexural toughness.Moreover,the composite mechanism between polypropylene fiber and concrete was analyzed and discussed.

  10. Nondestructive inspection of corrosion and delamination at the concrete-steel reinforcement interface

    Science.gov (United States)

    Miller, Tri Huu

    The proposed study explores the feasibility of detecting and quantifying corrosion and delamination (physical separation) at the interface between reinforcing steel bars and concrete using ultrasonic guided waves. The problem of corrosion of the reinforcing steel in structures has increased significantly in recent years. The emergence of this type of concrete deterioration, which was first observed in marine structures and chemical manufacturing plants, coincided with the increased applications of deicing salts (sodium and calcium chlorides) to roads and bridges during winter months in those states where ice and snow are of major concern. Concrete is strengthened by the inclusion of the reinforcement steel such as deformed or corrugated steel bars. Bonding between the two materials plays a vital role in maximizing performance capacity of the structural members. Durability of the structure is of concern when it is exposed to aggressive environments. Corrosion of reinforcing steel has led to premature deterioration of many concrete members before their design life is attained. It is therefore, important to be able to detect and measure the level of corrosion in reinforcing steel or delamination at the interface. The development and implementation of damage detection strategies, and the continuous health assessment of concrete structures then become a matter of utmost importance. The ultimate goal of this research is to develop a nondestructive testing technique to quantify the amount of corrosion in the reinforcing steel. The guided mechanical wave approach has been explored towards the development of such methodology. The use of an embedded ultrasonic network for monitoring corrosion in real structures is feasible due to its simplicity. The ultrasonic waves, specifically cylindrical guided waves can p ropagate a long distance along the reinforcing steel bars and are found to be sensitive to the interface conditions between steel bars and concrete. Ultrasonic

  11. Performance and Durability Evaluation of Bamboo Reinforced Cement Concrete Beams

    Directory of Open Access Journals (Sweden)

    Ankit Singh Mehra

    2016-04-01

    Full Text Available A big part of population in India is still homeless due to raising unaffordability of housing structures. People sleeping on roadsides and living in slums is a common sight in Indian cities. To overcome this problem India today needs millions of houses for their growing population, making concrete as the most widely to be used material in the country. Concrete has found to have excellent compressive strength but poor in tensile strength, to take care of the tensile stresses steel is commonly used as reinforcing material in concrete. Production of steel is a very costly business and its use in concrete as reinforcing material increases the cost of construction by many folds. Also production of steel emits a large amount of green house gases causing considerable deterioration of the environment. The above mentioned socio-economic and environmental factors creates a necessity for finding an appropriate environment friendly and cheap material that can successfully substitute steel as reinforcement in concrete elements of a low cost dwelling for the poor and homeless people of the country. It is here that engineered bamboo can be of great value to Civil Engineers owning to its several net worthy features. Production of every tone of bamboo consumes about a tone of atmospheric CO2 in addition to releasing fresh O2. From structural point of view bamboo has been used as a structural material from the earlier times as it possesses excellent flexure and tensile strength as well as high strength to weight ratio. All this necessitates examining bamboo-reinforced cement concrete in detail for its appropriateness as a structural material for construction of a low cost dwelling unit. The study focuses on evaluating the mechanical and durability properties of cement-concrete beams both singly and doubly reinforced with bamboo splints.

  12. Evaluation of size dependent design shear strength of reinforced concrete beams without web reinforcement

    Indian Academy of Sciences (India)

    G Appa Rao; S S Injaganeri

    2011-06-01

    Analytical studies on the effect of depth of beam and several parameters on the shear strength of reinforced concrete beams are reported. A large data base available has been segregated and a nonlinear regression analysis (NLRA) has been performed for developing the refined design models for both, the cracking and the ultimate shear strengths of reinforced concrete (RC) beams without web reinforcement. The shear strength of RC beams is size dependent, which needs to be evaluated and incorporated in the appropriate size effect models. The proposed models are functions of compressive strength of concrete, percentage of flexural reinforcement and depth of beam. The structural brittleness of large size beams seems to be severe compared with highly ductile small size beams at a given quantity of flexural reinforcement. The proposed models have been validated with the existing popular models as well as with the design code provisions.

  13. Passive Control Reinforced Concrete Frame Mechanism with High Strength Reinforcements and Its Potential Benefits Against Earthquakes

    Institute of Scientific and Technical Information of China (English)

    Asad Ullah Qazi; YE Lieping; LU Xinzheng

    2006-01-01

    Severe earthquakes continue to cause major catastrophes. Many devices in active, hybrid, and semi-active structural control systems which are used as controllable force devices are costly to build and maintain. The passive control reinforced concrete frame (PCRCF) reinforced with high strength steel only in the columns presented here provides structural systems more resistance to lateral earthquake loadings at comparatively lower cost. The effectiveness is demonstrated by a nonlinear static analysis using fiber model for a single story single bay frame. The study shows that the use of high performance steel in columns prevents formation of plastic hinges at the critical column base sections and failures are always initiated by reinforcement yielding at the beam ends. Furthermore, after experiencing severe lateral drift, the passive control design has small residual displacements compared to ordinary reinforced concrete frames. PCRCF rehabilitation and strengthening can be achieved more easily as compared with ordinary reinforced concrete frame.

  14. Crack Identification in Reinforced Concrete Beams Using Ansys Software

    OpenAIRE

    2014-01-01

    Analytical determination of displacements and stresses in reinforced concrete material was difficult task and engineers had to rely on empirical formulas because concrete consists of heterogeneous material and creep and shrinkage influenced deformations in it. Due to these complexities engineers in past had been facing difficulties in coping such problems, but with the advancement of digital computerization and modern numerical methods for analysis such as finite element metho...

  15. An Incursion on Punching of Reinforced Concrete Flat Slabs

    OpenAIRE

    2009-01-01

    Starting from the early 60s continuous studies have been made regarding punching of concrete flat slabs. The evolution of technology and calculus systems influenced this engineering branch. Nowadays is possible to account in structural analysis all the non-linear behaviour of reinforced and prestressed concrete and to get the most close structural response in comparison with the real behaviour. As a controversy matter, several tests and theories have been developed. Nowadays researchers try t...

  16. The Experimental Study of Concrete Beams Reinforced with Different Types of Bars Carrying Capacity

    OpenAIRE

    Benin Andrey; Semenov Sergey; Ekaterina Bogdanova

    2016-01-01

    The results of experimental study on concrete beams reinforced with glass fiber reinforced plastic (GFRP) bars are presented and compared with steel reinforced concrete beams and beams reinforced with steel and GFRP bars together. Three series of reinforced beams were tested in the flexure. The experimental data are showed that possible area in which GFRP bar possesses potential to employ is secondary reinforcement in concrete structures.

  17. The Experimental Study of Concrete Beams Reinforced with Different Types of Bars Carrying Capacity

    Directory of Open Access Journals (Sweden)

    Benin Andrey

    2016-01-01

    Full Text Available The results of experimental study on concrete beams reinforced with glass fiber reinforced plastic (GFRP bars are presented and compared with steel reinforced concrete beams and beams reinforced with steel and GFRP bars together. Three series of reinforced beams were tested in the flexure. The experimental data are showed that possible area in which GFRP bar possesses potential to employ is secondary reinforcement in concrete structures.

  18. Computational Homogenization of Fresh Concrete Flow Around Reinforcing Bars

    CERN Document Server

    Kolařík, Filip; Zeman, Jan

    2016-01-01

    Motivated by casting of fresh concrete in reinforced concrete structures, we introduce a numerical model of a steady-state non-Newtonian fluid flow through a porous domain. Our approach combines homogenization techniques to represent the reinforced domain by the Darcy law with an interface coupling of the Stokes and Darcy flows through the Beavers-Joseph-Saffman conditions. The ensuing two-scale problem is solved by the Finite Element Method with consistent linearization and the results obtained from the homogenization approach are verified against fully resolved direct numerical simulations.

  19. Observations on the electrical resistivity of steel fibre reinforced concrete

    DEFF Research Database (Denmark)

    Solgaard, Anders Ole Stubbe; Geiker, Mette Rica; Edvardsen, Carola;

    2014-01-01

    Steel fibre reinforced concrete (SFRC) is in many ways a well-known construction material, and its use has gradually increased over the last decades. The mechanical properties of SFRC are well described based on the theories of fracture mechanics. However, knowledge on other material properties......, including the electrical resistivity, is sparse. Among others, the electrical resistivity of concrete has an effect on the corrosion process of possible embedded bar reinforcement and transfer of stray current. The present paper provides experimental results concerning the influence of the fibre volume...

  20. Performance based design of reinforced concrete beams under impact

    Directory of Open Access Journals (Sweden)

    S. Tachibana

    2010-06-01

    Full Text Available The purpose of this research is to collect fundamental data and to establish a performance-based design method for reinforced concrete beams under perpendicular impact load.

    Series of low speed impact experiments using reinforced concrete beams were performed varying span length, cross section and main reinforcement.

    The experimental results are evaluated focusing on the impact load characteristics and the impact behaviours of reinforced concrete beams. Various characteristic values and their relationships are investigated such as the collision energy, the impact force duration, the energy absorbed by the beams and the beam response values. Also the bending performance of the reinforced concrete beams against perpendicular impact is evaluated.

    An equation is proposed to estimate the maximum displacement of the beam based on the collision energy and the static ultimate bending strength. The validity of the proposed equation is confirmed by comparison with experimental results obtained by other researchers as well as numerical results obtained by FEM simulations. The proposed equation allows for a performance based design of the structure accounting for the actual deformation due to the expected impact action.

  1. An Incursion on Punching of Reinforced Concrete Flat Slabs

    Directory of Open Access Journals (Sweden)

    Dan-Vasile Bompa

    2009-01-01

    Full Text Available Starting from the early 60s continuous studies have been made regarding punching of concrete flat slabs. The evolution of technology and calculus systems influenced this engineering branch. Nowadays is possible to account in structural analysis all the non-linear behaviour of reinforced and prestressed concrete and to get the most close structural response in comparison with the real behaviour. As a controversy matter, several tests and theories have been developed. Nowadays researchers try to find the most accurate and economic formula for punching. This paper purpose is to make a survey on punching classical model and related nonlinear concrete behaviour regarded to this issue.

  2. Durability of cracked fibre reinforced concrete structures exposed to chlorides

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place; Ekman, Tom; Hansen, Kurt Kielsgaard

    1999-01-01

    is used as environmental load. The chloride penetration is characterized both qualitatively (UV-test) and quantitatively (chloride profile) and by microscopy. The test programme involves three different concrete qualities. Both steel fibres and polypropylene fibres are used in the concrete beams as well......Durability studies are carried out by subjecting FRC-beams to combined mechanical and environmental load. Mechanical load is obtained by exposing beams to 4-point bending until a predefined crack width is reached, using a newly developed test setup. Exposure to a concentrated chloride solution...... as main reinforcement. The effect of the cracks, the fibres and the concrete quality on the chloride penetration is studied....

  3. Fiber-reinforced polymer concrete: Property improvement by gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Martinez B, G. [Laboratorio de Investigacion y Desarrollo de Materiales Avanzados, Facultad de Quimica, Universidad Autonoma del Estado de Mexico, Km. 12 Carretera Toluca-Atlacomulco, San Cayetano 50200, Estado de Mexico (Mexico); Brostow, W. [Laboratory of Advanced Polymers and Optimized Materials, Department of Materials Science and Engineering, University of North Texas, Denton TX 76203-5310 (United States)], e-mail: gonzomartinez02@yahoo.com.mx

    2009-07-01

    Polymer concrete (PC) is a particulate composite in which a thermoset resin forms a polymeric matrix and binds inorganic aggregates (dispersed particles of strengthening phases). This in contrast to Portland cement concrete (PCC) in which the binding is a result of interaction of cement with water. Adding polymeric materials to the concrete one can obtain high compressive and flexural strength, high impact and abrasion resistance, lower weight and lower costs. Moreover, PC is a very good repair material for structure elements damaged by trapping water inside the structure and by acid attacks which take place in the PCC. In the present chapter we discuss uses of polymer concrete and the importance of using gamma radiation as a novel technology for manufacturing fiber-reinforced polymer concrete. Our technology is different from the costly and time consuming current procedures such as chemical attack or thermal treatment. (Author)

  4. Concrete cover cracking with localized corrosion of reinforcing steel

    Energy Technology Data Exchange (ETDEWEB)

    Torres-Acosta, A. A.; Sagues, A. A. [South Florida Univ., Dept of Civil and Environmental Engineering, Tampa FL (United States)

    2000-07-01

    The critical amount of steel corrosion needed for concrete cover cracking of a reinforced concrete element was measured, focusing on cases where only a fraction of the steel bar length is corroding. The amount of corrosion needed to crack the concrete cover was found to range between 49 micrometre to 137 micrometre in specimens of localized corrosion. In contrast, in cases of uniform corrosion of comparable systems the corrosion needed to crack the concrete cover varied from 15 micrometre to 75 micrometer. Based on this and previous work on this problem, an empirical equation is proposed for the critical amount of steel corrosion as a function of specimen dimensions. The model proposed for estimating the critical amount of steel corrosion showed reasonable agreement between estimates of the work of corrosion expansion and the energy required to crack the concrete. 23 refs., 3 tabs., 8 figs.

  5. Engineered cementitious composites for strengthening masonry infilled reinforced concrete frames

    DEFF Research Database (Denmark)

    Dehghani, Ayoub; Nateghi-Alahi, Fariborz; Fischer, Gregor

    2015-01-01

    The results of the second part of a comprehensive experimental program, aimed at investigating the behavior of masonry infilled reinforced concrete (RC) frames strengthened with fiber reinforced engineered cementitious composites (ECC) used as an overlay on the masonry wall, are presented in this...... and energy absorption capacity of the infilled frame, prevent brittle failure modes in the infill wall, and provide a reasonable system overstrength....

  6. Numerical modelling of reinforced concrete beams with fracture-plastic material

    Directory of Open Access Journals (Sweden)

    O. Sucharda

    2014-10-01

    Full Text Available This paper describes the use of models of fracture-plastic materials for reinforced concrete in numerical modelling of beams made from reinforced concrete. The purpose of the paper is to use of a model of concrete for modelling of a behaviour of reinforced concrete beams which have been tested at the University of Toronto within re-examination of classic concrete beam tests. The original tests were performed by Bresler- Scordelis. A stochastic modelling based on LHS (Latin Hypercube Sampling has been performed for the reinforced concrete beam. An objective of the modelling is to evaluate the total bearing capacity of the reinforced concrete beams depending on distribution of input data. The beams from the studied set have longitudinal reinforcement only. The beams do not have any shear reinforcement. The software used for the fracture-plastic model of the reinforced concrete is the ATENA.

  7. Shear strengthening of reinforced concrete beams by means of vertical prestressed reinforcement

    OpenAIRE

    Santos Ferreira, Denise Carina; Bairán García, Jesús Miguel; Marí Bernat, Antonio Ricardo

    2016-01-01

    Strengthening reinforced concrete (RC) elements critical to shear with prestressed transversal reinforcement can be an efficient method to increase the shear resistance of structures, allowing the development of the full flexural capacity. However, research on the performance of this technique is very limited, and methods for designing the optimum amount of prestressed transversal reinforcement and assessing the retrofitted structure have not been produced yet. Nonlinear finite element models...

  8. Durability of cracked fibre reinforced concrete structures

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place; Nielsen, Laila

    1997-01-01

    (capillary water uptake) is used, involving an in-situ method and a laboratory method. Three different concrete qualities as well as steel fibres (ZP) and polypropylene fibres (PP) are used. Results of the durability tests on cracked FRC-beams are compared to results for uncracked FRC-beams and beams without...

  9. A RSM Method for Nonlinear Probabilistic Analysis of the Reinforced Concrete Structure Failure of a Nuclear Power Plant - Type VVER 440

    OpenAIRE

    Králik, Juraj

    2011-01-01

    This paper describes the reliability analysis of a concrete containment for VVER 440 under a high internal overpressure. The probabilistic safety assessment (PSA) level 3 aims at an assessment of the probability of the concrete structure failure under the excessive overpressure. The non-linear analysis of the concrete structures was considered. The uncertainties of the loads level (long-time temperature and dead loads), the material model (concrete cracking and crushing, behavior of the reinf...

  10. Stochastic Modeling of Reinforced Concrete Structures Exposed to Chloride Attack

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Frier, Christian

    2003-01-01

    concentration and reinforcement cover depth are modeled by stochastic fields. The paper contains a description of the parameters to be included in a stochastic model and a proposal for the information needed to obtain values for the parameters in order to be ab le to perform reliability investigations...... the reinforcement exceeds a critical threshold value. In the present paper a stochastic model is described by which the chloride content in a reinforced concrete structure can be estimated. The chloride ingress is modeled by a 2-dimensional diffusion process and the diffusion coefficient, surface chloride...

  11. Ultimate deformation capacity of reinforced concrete slabs underblast load

    NARCIS (Netherlands)

    Doormaal, J.C.A.M. van; Weerheijm, J.

    1996-01-01

    In this paper a test method to determine the deformation capacity and the resistance-deformation curve of blast-loaded slabs is described. This method was developed at TNO-PML. The method has been used to determine the ultimate deformation capacity of some simply supported reinforced concrete slabs

  12. Comparison of two novel approaches to model fibre reinforced concrete

    NARCIS (Netherlands)

    Radtke, F.K.F.; Simone, A.; Sluys, L.J.

    2009-01-01

    We present two approaches to model fibre reinforced concrete. In both approaches, discrete fibre distributions and the behaviour of the fibre-matrix interface are explicitly considered. One approach employs the reaction forces from fibre to matrix while the other is based on the partition of unity f

  13. Service Life and Maintenance Modelling of Reinforced Concrete Bridge Decks

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    Recent research in the area of assessment and maintenance of reinforced concrete bridge decks is presented in this paper. Three definitions of service lifetime are introduced and the difficult problem of assessing the service life is discussed. A stochastic modelling of corrosion and corrosion...

  14. Limit Analysis of 3D Reinforced Concrete Beam Elements

    DEFF Research Database (Denmark)

    Larsen, Kasper P.; Nielsen, Leif Otto; Poulsen, Peter Noe

    2012-01-01

    A new finite-element framework for lower-bound limit analysis of reinforced concrete beams, subjected to loading in three dimensions, is presented. The method circumvents the need for a direct formulation of a complex section-force-based yield criterion by creating a discrete representation of th...

  15. Stress wave propagation in reinforced concrete piles during driving

    NARCIS (Netherlands)

    Zorn, N.F.

    1983-01-01

    The aim of this report is to give an insight into what happens in a reinforced concrete pile during driving, and to contribute to design requirements for the loading case pile driving. Since the behaviour of stress waves in piles is influenced by a various number of parameters, the fewest of which r

  16. Optimisation of the Crack Pattern in Continuously Reinforced Concrete Pavements

    NARCIS (Netherlands)

    Ren, D.

    2015-01-01

    Recent field investigations on several new Continuously Reinforced Concrete Pavements (CRCP) in Belgium indicate that its crack pattern is characterized by low mean crack spacing along with a high percentage of clusters of closely spaced cracks. Field surveys also indicate that it is difficult to si

  17. Stress wave propagation in reinforced concrete piles during driving

    NARCIS (Netherlands)

    Zorn, N.F.

    1983-01-01

    The aim of this report is to give an insight into what happens in a reinforced concrete pile during driving, and to contribute to design requirements for the loading case pile driving. Since the behaviour of stress waves in piles is influenced by a various number of parameters, the fewest of which

  18. Optimisation of the Crack Pattern in Continuously Reinforced Concrete Pavements

    NARCIS (Netherlands)

    Ren, D.

    2015-01-01

    Recent field investigations on several new Continuously Reinforced Concrete Pavements (CRCP) in Belgium indicate that its crack pattern is characterized by low mean crack spacing along with a high percentage of clusters of closely spaced cracks. Field surveys also indicate that it is difficult to si

  19. Bending Resistance of Steel Plate-Reinforced Concrete Beam

    Institute of Scientific and Technical Information of China (English)

    TIAN Zhimin; CHEN Jie

    2006-01-01

    The formulas for calculating bending-resistant capacity of a steel plate-reinforced concrete composite beam are derived.To validate the formulas,experiments of the composite beam under three-point bending are carried out.Calculated results based on the formulas are in good agreement with experimental results.

  20. Dynamic Elasto-Plastic Model for Reinforced Concrete Members

    NARCIS (Netherlands)

    Van der Veen, C.; Blaauwendraad. J.

    1983-01-01

    It is becoming increasingly necessary to investigate the strength of reinforced concrete structures subjected to dynamic loading. Experience and knowledge relating to the non-linear dynamic behaviour of such structures is still limited, however. Attempts to solve this type of problems with the aid o

  1. Applicability Problem in Optimum Reinforced Concrete Structures Design

    Directory of Open Access Journals (Sweden)

    Ashara Assedeq

    2016-01-01

    Full Text Available Optimum reinforced concrete structures design is very complex problem, not only considering exactness of calculus but also because of questionable applicability of existing methods in practice. This paper presents the main theoretical mathematical and physical features of the problem formulation as well as the review and analysis of existing methods and solutions considering their exactness and applicability.

  2. Performance of steel-making slag concrete reinforced with fibers

    Directory of Open Access Journals (Sweden)

    Ortega-López Vanesa

    2017-01-01

    Full Text Available In this research, the possibility of making concrete reinforced with fibers and manufactured with recycled aggregates from carbon steel production was explored. Electric arc furnace slag (EAFS was used as coarse and medium aggregate, and part of the sand sizes. Metallic and synthetic fibers were added in different amounts. Initially, the properties of EAFS and their suitability to be used in the manufacture fiber reinforced concrete were analysed. Then, a series of fiber reinforced concrete mixtures were developed incorporating EAFS, and they were compared with the reference mixtures, made with conventional components plus fibers and made with EAFS without fibers. A series of tests were performed, including concepts such as consistency, compressive strength, flexural strength, splitting tensile strength, resistance to water penetration or toughness. The results show that it is possible to make a suitable steel-slag concrete reinforced with fibers, complying with the standard requirements for it use in pavements and slab, and improving their proprieties respect to the control mixtures.

  3. Probabilistic Fatigue Model for Reinforced Concrete Onshore Wind Turbine Foundations

    DEFF Research Database (Denmark)

    Marquez-Dominguez, Sergio; Sørensen, John Dalsgaard

    2013-01-01

    Reinforced Concrete Slab Foundation (RCSF) is the most common onshore wind turbine foundation type installed by the wind industry around the world. Fatigue cracks in a RCSF are an important issue to be considered by the designers. Causes and consequences of the cracks due to fatigue damage in RCSFs...

  4. Probabilistic Fatigue Model for Reinforced Concrete Onshore Wind Turbine Foundations

    DEFF Research Database (Denmark)

    Marquez-Dominguez, Sergio; Sørensen, John Dalsgaard

    2013-01-01

    Reinforced Concrete Slab Foundation (RCSF) is the most common onshore wind turbine foundation type installed by the wind industry around the world. Fatigue cracks in a RCSF are an important issue to be considered by the designers. Causes and consequences of the cracks due to fatigue damage in RCSFs...

  5. Optimisation of the Crack Pattern in Continuously Reinforced Concrete Pavements

    NARCIS (Netherlands)

    Ren, D.

    2015-01-01

    Recent field investigations on several new Continuously Reinforced Concrete Pavements (CRCP) in Belgium indicate that its crack pattern is characterized by low mean crack spacing along with a high percentage of clusters of closely spaced cracks. Field surveys also indicate that it is difficult to

  6. Rigid-plastic seismic design of reinforced concrete structures

    DEFF Research Database (Denmark)

    Costa, Joao Domingues; Bento, R.; Levtchitch, V.

    2007-01-01

    In this paper a new seismic design procedure for Reinforced Concrete (R/C) structures is proposed-the Rigid-Plastic Seismic Design (RPSD) method. This is a design procedure based on Non-Linear Time-History Analysis (NLTHA) for systems expected to perform in the non-linear range during a lifetime...

  7. Aspects of Robust Computational Modeling for Plain and Reinforced Concrete

    NARCIS (Netherlands)

    Feenstra, F.H.; De Borst, R.

    1993-01-01

    The problems commonly encountered in the numerical analysis of reinforced structures are often related to biaxial stress states in the structure. In this study this problem is solved with the formulation of a composite plasticity model which describes both cracking and crushing of concrete within th

  8. Ultimate deformation capacity of reinforced concrete slabs underblast load

    NARCIS (Netherlands)

    Doormaal, J.C.A.M. van; Weerheijm, J.

    1996-01-01

    In this paper a test method to determine the deformation capacity and the resistance-deformation curve of blast-loaded slabs is described. This method was developed at TNO-PML. The method has been used to determine the ultimate deformation capacity of some simply supported reinforced concrete slabs

  9. Prediction of residual shear strength of corroded reinforced concrete beams

    Science.gov (United States)

    Imam, Ashhad; Azad, Abul Kalam

    2016-09-01

    With the aim of providing experimental data on the shear capacity and behavior of corroded reinforced concrete beams that may help in the development of strength prediction models, the test results of 13 corroded and four un-corroded beams are presented. Corrosion damage was induced by accelerated corrosion induction through impressed current. Test results show that loss of shear strength of beams is mostly attributable to two important damage factors namely, the reduction in stirrups area due to corrosion and the corrosion-induced cracking of concrete cover to stirrups. Based on the test data, a method is proposed to predict the residual shear strength of corroded reinforced concrete beams in which residual shear strength is calculated first by using corrosion-reduced steel area alone, and then it is reduced by a proposed reduction factor, which collectively represents all other applicable corrosion damage factors. The method seems to yield results that are in reasonable agreement with the available test data.

  10. 77 FR 70140 - Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia, Moldova, Poland, People's...

    Science.gov (United States)

    2012-11-23

    ...] Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia, Moldova, Poland, People's Republic of...'') initiated the second Sunset Reviews of the antidumping duty orders on steel concrete reinforcing bars from.... SUPPLEMENTARY INFORMATION: Background The antidumping duty orders on steel concrete reinforcing bars from...

  11. 77 FR 64127 - Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and...

    Science.gov (United States)

    2012-10-18

    ... COMMISSION Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and... determine whether revocation of the antidumping duty orders on steel concrete reinforcing bar from Belarus... concrete reinforcing bar from Latvia and Moldova. The Commission found that the respondent interested party...

  12. 77 FR 18973 - Reinforced Concrete in Construction, and Preventing Backover Injuries and Fatalities

    Science.gov (United States)

    2012-03-29

    ... Reinforced Concrete in Construction, and Preventing Backover Injuries and Fatalities AGENCY: Occupational... aware of employee safety risks in two areas, reinforcing operations in concrete work (construction only... following methods (submissions relating to Reinforced Concrete in Construction to Docket No. OSHA-2010-0058...

  13. Influence of reinforcement mesh configuration for improvement of concrete durability

    Science.gov (United States)

    Pan, Chong-gen; Jin, Wei-liang; Mao, Jiang-hong; Zhang, Hua; Sun, Li-hao; Wei, Dong

    2017-08-01

    Steel bar in concrete structures under harsh environmental conditions, such as chlorine corrosion, seriously affects its service life. Bidirectional electromigration rehabilitation (BIEM) is a new method of repair technology for reinforced concrete structures in such chloride corrosion environments. By applying the BIEM, chloride ions can be removed from the concrete and the migrating corrosion inhibit can be moved to the steel surface. In conventional engineering, the concrete structure is often configured with a multi-layer steel mesh. However, the effect of the BIEM in such structures has not yet been investigated. In this paper, the relevant simulation test is carried out to study the migration law of chloride ions and the migrating corrosion inhibitor in a concrete specimen with complex steel mesh under different energizing modes. The results show that the efficiency of the BIEM increases 50% in both the monolayer steel mesh and the double-layer steel mesh. By using the single-sided BIEM, 87% of the chloride ions are removed from the steel surface. The different step modes can affect the chloride ion removal. The chloride ions within the range of the reinforcement protective cover are easier to be removed than those in the concrete between the two layers of steel mesh. However, the amount of migrating corrosion inhibitor is larger in the latter circumstances.

  14. Corrosion Effects on the Strength Properties of Steel Fibre Reinforced Concrete Containing Slag and Corrosion Inhibitor

    OpenAIRE

    Sivakumar Anandan; Sounthararajan Vallarasu Manoharan; Thirumurugan Sengottian

    2014-01-01

    Corrosion in steel can be detrimental in any steel rebar reinforced concrete as well as in the case of steel fibre reinforced concrete. The process of corrosion occurring in steel fibre incorporated concrete subjected to corrosive environment was systematically evaluated in this study. Concrete specimens were prepared with steel fibre inclusions at 1.5% Vf (volume fraction) of concrete and were added in slag based concrete (containing manufactured sand) and replaced with cement at 20%, 40%, ...

  15. Polarization Induced Deterioration of Reinforced Concrete with CFRP Anode

    Directory of Open Access Journals (Sweden)

    Ji-Hua Zhu

    2015-07-01

    Full Text Available This paper investigates the deterioration of reinforced concrete with carbon fiber reinforced polymer (CFRP anode after polarization. The steel in the concrete was first subjected to accelerated corrosion to various extents. Then, a polarization test was performed with the external attached CFRP as the anode and the steel reinforcement as the cathode. Carbon fiber reinforced mortar and conductive carbon paste as contact materials were used to adhere the CFRP anode to the concrete. Two current densities of 1244 and 2488 mA/m2, corresponding to the steel reinforcements were applied for 25 days. Electrochemical parameters were monitored during the test period. The deterioration mechanism that occurred at the CFRP/contact material interface was investigated by scanning electron microscopy (SEM and X-ray diffraction (XRD techniques. The increase of feeding voltage and the failure of bonding was observed during polarization process, which might have resulted from the deterioration of the interface between the contact material and CFRP. The formation and accumulation of NaCl crystals at the contact material/CFRP interface were inferred to be the main causes of the failure at the interface.

  16. Waste Plastic Fibre Reinforced Self Compacting Concrete

    Directory of Open Access Journals (Sweden)

    Mrs. Vijaya G.S Assistant Professor

    2016-05-01

    Full Text Available Self-compacting concrete is high performance concrete which is highly flowable, non-segregating, spread on its own weight and doesn‟t need any compaction. This paper deals with flow and strength characteristics such as compressive strength, split tensile strength, flexural strength and impact strength of Self-compacting concrete with various percentages of waste plastic fibres like 0%, 0.25%, 0.5%, 0.75%, 1.0%, 1.1%, 1.20%, 1.3% and 1.4% is added by weight of cement. The mix proportion for M40 grade of concrete was done by using Nan Su method (Cement: GGBS: Fine aggregate: Course aggregate 1: 0.705: 3.34: 2.62. Water powder (W/P ratio 0.36, cement content 280kg/m3 , GGBS 220 kg/m3 was calculated and maintained as constant throughout the experimental work for all eight mixes, only the superplastizers dosage was varied for different percentage of fibres. In this experimental investigation one control mix and eight (8 different mixes were considered. Totally 81 Cube, beam, Cylindrical specimens and square plates were casted, cured and tested as per IS specifications. For determining impact strength drop weight method was used. The results obtained indicate that fresh (workability characteristics satisfy the lower and upper limit as suggested by EFNARC. The tests on hardened properties indicate that the compressive strength, split tensile strength, flexural strength was improved proportionally with the addition of waste plastic fibers upto 1.0% by weight of cement and then decreases. The impact strength improved proportionally with addition of fibres upto 1.2% by weight of cement and then decreases.

  17. Chloride Ion Critical Content in Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Chloride ion critical content was studied under soaking and cycle of dry and wet conditions,with three electrochemical nondestructive measuring techniques, i e, half-cell potential, A C impedance, and time potential. The experimental results show that chloride ion critical content is primarily determined by the water cement ratio, while for the same concrete mixture the chloride ion critical content in soaking conditions is larger than that in a cycle of dry and wet conditions.

  18. Proposal of a new indicator to define ductility applied to corroded steel reinforcement on concrete structures

    OpenAIRE

    Cobo Escamilla, Alfonso; Moreno Fernandez, Maria Esther; Fernández Cánovas, Manuel

    2010-01-01

    The carbonation of concrete or the chlorides ingress in such quantity to reach the level of bars is triggers of reinforcement corrosion. One of the most significant effects of reinforcing steel corrosion on reinforced concrete structures is the decline in the ductility-related properties of the steel. Reinforcement ductility has a decisive effect on the overall ductility of reinforced concrete structures. Different Codes classify the type of steel depending on their ductility defined by...

  19. COMPOSITE STRENGTHENING SOLUTIONS FOR REINFORCED CONCRETE LOAD BEARING ELEMENTS

    Directory of Open Access Journals (Sweden)

    Nicolae ȚĂRANU

    2015-11-01

    Full Text Available The results of a complex research and development program relating to the use of fiber reinforced polymeric composite strengthening solutions carried out at the Faculty of Civil Engineering and Building Services Iasi, are presented in this paper. The program has included the conceiving of the structural rehabilitation systems, the detailing and experimental testing of some solutions applied to reinforced concrete beams, slabs and columns (with circular and square cross-section. An efficient use of the component materials to improve the structural performance of the studied reinforced concrete element has been the main target of the research program. The main benefits resulted from the research program refer to the increase of the load capacities, the improvement of the structural response of all strengthened elements and a better control of the failure modes.

  20. A Study on Steel Fiber Reinforced Normal Compacting Concrete

    Directory of Open Access Journals (Sweden)

    Dr. B. Krishna Rao,

    2016-08-01

    Full Text Available Plain concrete which is strong in compressive strength possesses a very low tensile strength, limited ductility and little resistance to cracking. Internal micro cracks are inherently present in the concrete due to drying, shrinkage and poor tensile strength, eventually leading to brittle fracture of concrete. Hence fibres are added to concrete to overcome these disadvantages. Fibre Reinforced Concrete (FRC is a concrete composite of cement, fine and coarse aggregate and fibres with different proportions. In plain concrete, micro cracks develop even before loading, particularly due to drying, shrinkage or other causes of volume change. The width of these initial cracks seldom exceeds few microns. When loaded the micro cracks propagate and open up, due to the effect of stress concentration additional cracks form in place of minor defects. Fibres enable concrete to progress from plastic state to hardened state without weakness. This is achieved by the reduction of micro crack formation, reduced segregation and decreasing the scope of capillary formation, thus reducing permeability. Generally, fibres are chosen depending upon the aspect ratio. Out of all types of fibres, steel fibres are mostly used because steel has high modulus of elasticity, high elongation, high tensile strength and the bond between steel and the fibre is enormous. The present experimental investigation was carried out to evaluate the influence of steel fibres on physical and mechanical properties of concrete, containing cold drawn carbon steel fibres of hooked end type having aspect ratio of 50 with diameter 0.6mm and length 30mm with varying percentages of 0.5%, 1%, 1.5% and 2.0% volume fraction is added to the concrete. Concrete is evaluated for compressive, split tensile and flexural strength at 7, 28 and 90 days, with the addition of 1.5% fibres, test results show the maximum compressive, split tensile and flexural strength, it becomes the optimum value. Split tensile and

  1. Modeling the Time-to Corrosion Cracking of the Cover Concrete in Chloride Contaminated Reinforced Concrete Structures

    OpenAIRE

    Liu, Youping

    1996-01-01

    Significant factors on steel corrosion in chloride contaminated reinforced concrete and time-to-corrosion cracking were investigated in this study. Sixty specimens were designed with seven admixed chloride contents, three concrete cover depths, two reinforcing steel bar diameters, two exposure conditions, and a typical concrete with water to cement ratio of 0.45. Corrosion current density (corrosion rate), corrosion potential, ohmic resistance of concrete and temperature were measured monthly...

  2. Effect Of Age And Concrete Cover Thickness On Steel Reinforcement Corrosion At Splash Zone In Reinforced Concrete Hydraulic Structures

    Directory of Open Access Journals (Sweden)

    Nada M. Al- Galawi

    2015-08-01

    Full Text Available Corrosion of reinforcing steel bars in reinforced concrete is considered as one of the biggest problems that face countries overlooking to the Arabian Gulf including Iraq. The research aims to study the effect of the corrosion of steel bars in concrete structures that are exposed to wetting and drying via waves. Reinforced concrete samples were exposed to marine simulated environment for 90 days using prepared system for this purpose. At the end of exposure period polarization test was implemented to measure the actual corrosion rate in each sample. After that the corrosion process was accelerated using impressed current technique by applying a constant electric current DC to the reinforcing bars. Depending on the corrosion current in natural conditions which was measured in polarization test periods of exposing samples to accelerated corrosion current so as to maintain virtual exposure ages of 5 and 25 years of exposure to natural corrosion were calculated. The results showed a remarkable increase in the corrosion current of steel bars in samples that had lower concrete cover thickness. The increase in the cover thickness from 20mm to 40 and 65 mm had a significant effect on reducing the corrosion current at the age of 90 days to about 70 of its original value in both cases. At the virtual exposure age of 5 years the reduction percentage in the corrosion current resulted from increasing cover thickness from 20mm to 40 and 65 mm were 43 and 79 respectively.

  3. Bamboo Reinforced Concrete Truss Bridge for Rural Infrastructure

    Directory of Open Access Journals (Sweden)

    D. Nuralinah

    2014-04-01

    Full Text Available Bamboo is one of a potential renewable construction material in the village. Bamboo is known to have a high mechanical strength in direction of the fibers. The weakness of bamboo in lateral direction of the fiber could be solved by constructing a composite structure with the concrete. The appropriate construction with hold the loads in axial direction is a truss structure. In a bamboo concrete truss structure, the bars are composed from the concrete column with a bamboo reinforcement. The research studies about the performance of the bridge and the effect of loading position on the strain and deformation of bamboo reinforced concrete truss bridge. The bridge whose span and width are respectively 1.5 m and 1.2 m was prepared. Load applied to the truss bridge conducted by using vehicle load changes with position. Mounting the strains gauge in bamboo reinforcement of primary truss is to observe the strain. The LVDT is used to observe the deflection of the truss bridge. The results show that the loading position influences the strain and deformation as well as a theoretical view.

  4. Influence of transverse reinforcement on perforation resistance of reinforced concrete slabs under hard missile impact

    Energy Technology Data Exchange (ETDEWEB)

    Orbovic, Nebojsa, E-mail: nebojsa.orbovic@cnsc-ccsn.gc.ca; Sagals, Genadijs; Blahoianu, Andrei

    2015-12-15

    This paper describes the work conducted by the Canadian Nuclear Safety Commission (CNSC) related to the influence of transverse reinforcement on perforation capacity of reinforced concrete (RC) slabs under “hard” missile impact (impact with negligible missile deformations). The paper presents the results of three tests on reinforced concrete slabs conducted at VTT Technical Research Centre (Finland), along with the numerical simulations as well as a discussion of the current code provisions related to impactive loading. Transverse reinforcement is widely used for improving the shear and punching strength of concrete structures. However, the effect of this reinforcement on the perforation resistance under localized missile impact is still unclear. The goal of this paper is to fill the gap in the current literature related to this topic. Based on similar tests designed by the authors with missile velocity below perforation velocity, it was expected that transverse reinforcement would improve the perforation resistance. Three slabs were tested under almost identical conditions with the only difference being the transverse reinforcement. One slab was designed without transverse reinforcement, the second one with the transverse reinforcement in form of conventional stirrups with hooks and the third one with the transverse reinforcement in form of T-headed bars. Although the transverse reinforcement reduced the overall damage of the slabs (the rear face scabbing), the conclusion from the tests is that the transverse reinforcement does not have important influence on perforation capacity of concrete slabs under rigid missile impact. The slab with T-headed bars presented a slight improvement compared to the baseline specimen without transverse reinforcement. The slab with conventional stirrups presented slightly lower perforation capacity (higher residual missile velocity) than the slab without transverse reinforcement. In conclusion, the performed tests show slightly

  5. Study of Bond Characteristics of Reinforced Waste Glass Aggregate Concrete

    Science.gov (United States)

    Rajagopalan, P.; Balaji, V.; Unnikrishnan, N.; Jainul Haq, T.; Bhuvaneshwari, P.

    2017-07-01

    The conformity of properties of waste glass aggregate with conventional aggregate was found out. Nine cubes (150mm x 150mm x 150mm) were cast out of which three were used for control concrete, three were fully replaced with waste glass as coarse aggregate, three were partially replaced(50%) with waste glass as fine aggregate. Six cylinders (150mm x 300mm) were cast out of which two for control concrete, two cylinders with coarse aggregate fully replaced with waste glass aggregate(WGA) and remaining two cylinders with partially replaced (50%) fine aggregate with waste glass aggregate. Cured specimens were subjected to compression and split-tensile test to ascertain the characteristic compressive strength and split tensile strength. Since the surface of the coarse aggregate plays a significant role in bonding of the rebar in reinforced concrete, pull-out test on both control and Waste Glass Aggregate (WGA) cube specimens (150mm x 150mm with 20mm diameter steel rods) were conducted. Scanning Electron Microscopy (SEM) analysis has been done for better understanding of bonding properties in waste glass fine aggregate(WGFA) and waste glass coarse aggregate(WGCA) concrete. Comparison of the results with that of control specimens showed that waste glass could be effectively used as aggregates in reinforced concrete construction.

  6. Nonlinear Finite Element Analysis of Reinforced Concrete Shells

    Directory of Open Access Journals (Sweden)

    Mustafa K. Ahmed

    2013-05-01

    Full Text Available This investigation is to develop a numerical model suitable for nonlinear analysis of reinforced concrete shells. A nine-node Lagrangian element Figure (1 with enhanced shear interpolation will be used in this study. Table (1 describes shape functions and their derivatives of this element.An assumed transverse shear strain is used in the formulation of this element to overcome shear locking. Degenerated quadratic thick plate elements employing a layered discrelization through the thickness will be adopted. Different numbers of layers for different thickness can be used per element. A number of layers between (6 and 10 have proved to be appropriate to represent the nonlinear material behavior in structures. In this research 8 layers will be adequate. Material nonlinearities due to cracking of concrete, plastic flow or crushing of concrete in compression and yield condition of reinforcing steel are considered. The maximum tensile strength is used as a criterion for crack initiation. Attention is given to the tension stiffening phenomenon and the degrading effect of cracking on the compressive and shear strength of concrete. Perfect bond between concrete and steel is assumed. Attention is given also to geometric nonlinearities. An example have been chosen in order to demonstrate the suitability of the models by comparing the predicted behaviour with the experimental results for shell exhibiting various modes of failure.

  7. Mechanical Properties of Fiber Reinforced Lightweight Concrete Containing Surfactant

    Directory of Open Access Journals (Sweden)

    Yoo-Jae Kim

    2010-01-01

    Full Text Available Fiber reinforced aerated lightweight concrete (FALC was developed to reduce concrete's density and to improve its fire resistance, thermal conductivity, and energy absorption. Compression tests were performed to determine basic properties of FALC. The primary independent variables were the types and volume fraction of fibers, and the amount of air in the concrete. Polypropylene and carbon fibers were investigated at 0, 1, 2, 3, and 4% volume ratios. The lightweight aggregate used was made of expanded clay. A self-compaction agent was used to reduce the water-cement ratio and keep good workability. A surfactant was also added to introduce air into the concrete. This study provides basic information regarding the mechanical properties of FALC and compares FALC with fiber reinforced lightweight concrete. The properties investigated include the unit weight, uniaxial compressive strength, modulus of elasticity, and toughness index. Based on the properties, a stress-strain prediction model was proposed. It was demonstrated that the proposed model accurately predicts the stress-strain behavior of FALC.

  8. EMBEDDED CAPACITOR SENSOR FOR MONITORING CORROSION OF REINFORCEMENT IN CONCRETE

    Directory of Open Access Journals (Sweden)

    SITI FATIMAH ABDUL RAHMAN

    2012-04-01

    Full Text Available Corrosion of reinforcement can affect durability and integrity of reinforced concrete structures. Repair cost for a badly corroded structure can be very costly and time consuming. In this paper, several capacitor sensors were developed to monitor corrosion potential of reinforcement in concrete. The impedance capacitive of sensors was tested in various acid and alkali solutions using Agilent 4284A Precision LCR meter. The other sensors were tied to reinforcements and embedded in concrete specimen contaminated with 5% chloride to measure corrosion potential. The specimens were exposed to the corrosion chamber and indoor environments. From the research, it was found that the sensor can measure the impedance capacitive at different frequencies in the aggressive solutions. Besides, it was observed that the patterns of corrosion potential shown by the embedded sensors were similar to the SRI sensor. The output values from embedded sensor are in a range of recommendation by the ASTM-C876. Eventually, the bars were found corroded from the broken specimens that confirmed the detection of corrosion activities as recorded by the sensors.

  9. REPAIR AND STRENGTHENING OF REINFORCED CONCRETE BEAMS USING FIBRE REINFORCED POLIMER (FRP MATERIALS

    Directory of Open Access Journals (Sweden)

    Nihat ÇETİNKAYA

    2004-03-01

    Full Text Available The use of Fibre Reinforced Polimer (FRP materials for the repair and strengthening of Reinforced Concrete structures has become widespread recently. FRP materials are being prefered because they have very high tensile strength, resistance to corrosion and they do not affect the use of the building during the repair and strengthening process. Four reinfoced concrete beams repaired and strengthened with FRP materials have been used in this study which were performed at Pamukkale University-Faculty of Engineering- Civil Engineering Department- Structural Engineering Laboratuary. The behaviour of the beams before and after repair and strengthening was compared by obtaining the load- displacement curves under static loading. In this study, it was observed that the repair and strengthening of reinforced concrete beams by using FRP materials had increased the load carrying capacity significantly.

  10. Review of Carbon Fiber Reinforced Polymer Reinforced Material in Concrete Structure

    Directory of Open Access Journals (Sweden)

    Ayuddin Ayuddin

    2016-05-01

    Full Text Available Carbon Fiber Reinforced Polymer (FRP is a material that is lightweight, strong, anti-magnetic and corrosion resistant. This material can be used as an option to replace the steel material in concrete construction or as material to improve the strength of existing construction. CFRP is quite easy to be attached to the concrete structure and proved economically used as a material for repairing damaged structures and increase the resilience of structural beams, columns, bridges and other parts of the structure against earthquakes. CFRP materials can be shaped sheet to be attached to the concrete surface. Another reason is due to the use of CFRP has a higher ultimate strength and lower weight compared to steel reinforcement so that the handling is significantly easier. Through this paper suggests that CFRP materials can be applied to concrete structures, especially on concrete columns. Through the results of experiments conducted proved that the concrete columns externally wrapped with CFRP materials can increase the strength. This treatment is obtained after testing experiments on 130 mm diameter column with a height of 700 mm with concentric loading method to collapse. The experimental results indicate that a column is wrapped externally with CFRP materials can achieve a load capacity of 250 kN compared to the concrete columns externally without CFRP material which only reached 150 kN. If the column is given internally reinforcing steel and given externally CFRP materials can reach 270 kN. It shows that CFRP materials can be used for concrete structures can even replace reinforcing steel that has been widely used in building construction in Indonesia.

  11. The Effect of Externally Retrofitted Carbon Fiber Reinforced Polymer Composites on the Ductility of Reinforced Concrete Beams

    Science.gov (United States)

    2007-11-02

    Reinforcement Ratios 84 8-5 Ductility Indices 86 5 LIST OF FIGURES FIGURE PAGE 2-1 Failure Modes of Concrete Beams 17 2-2 Composite Jacket Installation...20 2-3 Composite Jacket Application 20 2-4 Four Point Bending Configuration 21 3-1 Stress-Strain Relationship for Concrete 27 3-2 Standard Rebar 28 3...researchers around the world, such as reinforcing and prestressing concrete structures, seismic retrofitting of concrete and unreinforced masonry

  12. Effect of Reinforcement on Early-Age Concrete Temperature Stress: Preliminary Experimental Investigation and Analytical Simulation

    Directory of Open Access Journals (Sweden)

    Jianda Xin

    2015-01-01

    Full Text Available For concrete under short-term loading, effect of reinforcement on concrete crack resistance capability is usually negligible; however, recent research results show that extension of this viewpoint to concrete under long-term loading (temperature variation may be unsuitable. In order to investigate this phenomenon, this paper presents the experimental and analytical results of early-age reinforced concrete temperature stress development under uniaxial restraint. The experiments were carried out on a temperature stress testing machine (TSTM. Experimental results show that the coupling of reinforcement and concrete creep behavior influenced the concrete temperature stress development, and nearly 16% of concrete stress was reduced in the current research. Moreover, the cracking time of reinforced concrete was also delayed. Finally, based on the principle of superposition, analytical simulations of effect of reinforcement on concrete temperature stress have been performed.

  13. Shear Strengthening of Reinforced Concrete Beams Using GFRP Wraps

    Directory of Open Access Journals (Sweden)

    M. A. A. Saafan

    2006-01-01

    Full Text Available The objective of the experimental work described in this paper was to investigate the efficiency of GFRP composites in strengthening simply supported reinforced concrete beams designed with insufficient shear capacity. Using the hand lay-up technique, successive layers of a woven fiberglass fabric were bonded along the shear span to increase the shear capacity and to avoid catastrophic premature failure modes. The strengthened beams were fabricated with no web reinforcement to explore the efficiency of the proposed strengthening technique using the results of control beams with closed stirrups as a  web reinforcement. The test results of 18 beams are reported, addressing the influence of different shear strengthening schemes and variable longitudinal reinforcement ratios on the structural behavior. The results indicated that significant increases in the shear strength and improvements in the overall structural behavior of beams with insufficient shear capacity could be achieved by proper application of GFRP wraps.

  14. Critical chloride content for reinforced concrete and its relationship to concrete resistivity

    NARCIS (Netherlands)

    Polder, R.B.

    2009-01-01

    The critical chloride content for initiation of reinforcement corrosion is an essential element in service life design and modelling of concrete structures.The critical content is laden with questions regarding its definition, experimental assessment and practical aspects. It should be addressed by

  15. Up-to-date technologies of producing reinforced concrete constructions in transport industry

    Directory of Open Access Journals (Sweden)

    Ю. А. Клімов

    2000-09-01

    Full Text Available Presented is the analysis of the works at XIII Congress of International Federeation of pre­reinforced concrete construction (FIP. Scientific researches and technical solutions of reinforced concrete constructions realized in the developed countries have determined the main trends in perfection of concrete constructions in the next century (perfection of data on quality of constructive solutions of reinforcement with on-metallic fibrous materials, energy saving technologies of concrete production, development and investigation of perspective technical solutions

  16. An extended finite element model for modelling localised fracture of reinforced concrete beams in fire

    OpenAIRE

    Liao, F; Huang, Z.

    2015-01-01

    Open Access funded by Engineering and Physical Sciences Research Council under a Creative Commons license. A robust finite element procedure for modelling the localised fracture of reinforced concrete beams at elevated temperatures is developed. In this model a reinforced concrete beam is represented as an assembly of 4-node quadrilateral plain concrete, 3-node main reinforcing steel bar, and 2-node bond-link elements. The concrete element is subdivided into layers for considering the temp...

  17. Advance study of fiber-reinforced self-compacting concrete

    Energy Technology Data Exchange (ETDEWEB)

    Mironova, M., E-mail: mirona@imbm.bas.bg; Ivanova, M., E-mail: magdalena.ivanova@imbm.bas.bg; Naidenov, V., E-mail: valna53@mail.bg [Institute of Mechanics, Bulgarian Academy of Sciences, Acad. G. Bonchev str., bl. 4, Sofia 1113 (Bulgaria); Georgiev, I., E-mail: ivan.georgiev@parallel.bas.bg [Institute of Information and Communication Technologies & Institute of Mathematics and Informatics, Bulgarian Academy of Sciences, Acad. G. Bonchev str., Sofia 1113 (Bulgaria); Stary, J., E-mail: stary@ugn.cas.cz [Institute of Geonics Czech Academy of Sciences, Studentska str., Ostrava 1768 (Czech Republic)

    2015-10-28

    Incorporation in concrete composition of steel macro- and micro – fiber reinforcement with structural function increases the degree of ductility of typically brittle cement-containing composites, which in some cases can replace completely or partially conventional steel reinforcement in the form of rods and meshes. Thus, that can reduce manufacturing, detailing and placement of conventional reinforcement, which enhances productivity and economic efficiency of the building process. In this paper, six fiber-reinforced with different amounts of steel fiber cement-containing self-compacting compositions are investigated. The results of some of their main strength-deformation characteristics are presented. Advance approach for the study of structural and material properties of these type composites is proposed by using the methods of industrial computed tomography. The obtained original tomography results about the microstructure and characteristics of individual structural components make it possible to analyze the effective macro-characteristics of the studied composites. The resulting analytical data are relevant for the purposes of multi-dimensional modeling of these systems. Multifactor structure-mechanical analysis of the obtained with different methods original scientific results is proposed. It is presented a conclusion of the capabilities and effectiveness of complex analysis in the studies to characterize the properties of self-compacting fiber-reinforced concrete.

  18. Advance study of fiber-reinforced self-compacting concrete

    Science.gov (United States)

    Mironova, M.; Ivanova, M.; Naidenov, V.; Georgiev, I.; Stary, J.

    2015-10-01

    Incorporation in concrete composition of steel macro- and micro - fiber reinforcement with structural function increases the degree of ductility of typically brittle cement-containing composites, which in some cases can replace completely or partially conventional steel reinforcement in the form of rods and meshes. Thus, that can reduce manufacturing, detailing and placement of conventional reinforcement, which enhances productivity and economic efficiency of the building process. In this paper, six fiber-reinforced with different amounts of steel fiber cement-containing self-compacting compositions are investigated. The results of some of their main strength-deformation characteristics are presented. Advance approach for the study of structural and material properties of these type composites is proposed by using the methods of industrial computed tomography. The obtained original tomography results about the microstructure and characteristics of individual structural components make it possible to analyze the effective macro-characteristics of the studied composites. The resulting analytical data are relevant for the purposes of multi-dimensional modeling of these systems. Multifactor structure-mechanical analysis of the obtained with different methods original scientific results is proposed. It is presented a conclusion of the capabilities and effectiveness of complex analysis in the studies to characterize the properties of self-compacting fiber-reinforced concrete.

  19. Effects of Reinforcement Configuration on Reserve Capacity of Concrete Slabs

    Science.gov (United States)

    1985-08-01

    Reinforced concreted Tensile membrane,, Buried shelters/ Shelters/ ..i, Civil defense, Slab capacity, 120. A34TlRACT rCcnhma in~ r aidit noe..era aad...CHAPTER 1 I XTPODLCT, CI At the- iiti it io., of this Study civil d~efense plwlgcalled for the .;evacuation of nonessenrt*I51 pezrsonnel to safe (lower...lqbal and Derecho (Reference 10). The reinforcement ratio, p , was 0.0062 in "Christianscn’s te,;tts and varied from 0.0023 to 0.0093 in Roberts’ tests

  20. Behavior of reinforced concrete columns strenghtened by partial jacketing

    Directory of Open Access Journals (Sweden)

    D. B. FERREIRA

    Full Text Available This article presents the study of reinforced concrete columns strengthened using a partial jacket consisting of a 35mm self-compacting concrete layer added to its most compressed face and tested in combined compression and uniaxial bending until rupture. Wedge bolt connectors were used to increase bond at the interface between the two concrete layers of different ages. Seven 2000 mm long columns were tested. Two columns were cast monolithically and named PO (original column e PR (reference column. The other five columns were strengthened using a new 35 mm thick self-compacting concrete layer attached to the column face subjected to highest compressive stresses. Column PO had a 120mm by 250 mm rectangular cross section and other columns had a 155 mm by 250mm cross section after the strengthening procedure. Results show that the ultimate resistance of the strengthened columns was more than three times the ultimate resistance of the original column PO, indicating the effectiveness of the strengthening procedure. Detachment of the new concrete layer with concrete crushing and steel yielding occurred in the strengthened columns.

  1. Fatigue Strain and Damage Analysis of Concrete in Reinforced Concrete Beams under Constant Amplitude Fatigue Loading

    Directory of Open Access Journals (Sweden)

    Fangping Liu

    2016-01-01

    Full Text Available Concrete fatigue strain evolution plays a very important role in the evaluation of the material properties of concrete. To study fatigue strain and fatigue damage of concrete in reinforced concrete beams under constant amplitude bending fatigue loading, constant amplitude bending fatigue experiments with reinforced concrete beams with rectangular sections were first carried out in the laboratory. Then, by analyzing the shortcomings and limitations of existing fatigue strain evolution equations, the level-S nonlinear evolution model of fatigue strain was constructed, and the physical meaning of the parameters was discussed. Finally, the evolution of fatigue strain and fatigue damage of concrete in the compression zone of the experimental beam was analyzed based on the level-S nonlinear evolution model. The results show that, initially, fatigue strain grows rapidly. In the middle stages, fatigue strain is nearly a linear change. Because the experimental data for the third stage are relatively scarce, the evolution of the strain therefore degenerated into two phases. The model has strong adaptability and high accuracy and can reflect the evolution of fatigue strain. The fatigue damage evolution expression based on fatigue strain shows that fatigue strain and fatigue damage have similar variations, and, with the same load cycles, the greater the load level, the larger the damage, in line with the general rules of damage.

  2. Producing Durable Continuously Reinforced Concrete Pavement using Glass-ceramic Coated Reinforcing Steel

    Science.gov (United States)

    2010-02-01

    Portland cement is manufactured by firing the clinker at 1400 C Enamel application produces no changes BUILDING STRONG® Treatment Average Peak...ceramic Coated Reinforcing Steel 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER... transition zone at the surface of the reinforcement steel is often the most permeable part of the concrete BUILDING STRONG® Schematic of Ceramic

  3. Optimal Material Layout - Applied on Reinforced Concrete Slabs

    DEFF Research Database (Denmark)

    Dollerup, Niels; Jepsen, Michael S.; Damkilde, Lars

    2015-01-01

    to determine the optimal material layout of a slab in the ultimate load state, based on simple inputs such as outer geometry, boundary conditions, multiple load cases and design domains. The material layout of the optimal design can either be fully orthotropic or isotropic, or a combination with a predefined......This paper introduces a general, finite-element-based optimisation tool for improving the material layout of concrete structures. The application presented is general and exemplified by material optimisation of reinforced concrete slabs. By utilising the optimisation tool, it is possible...... coupling between design domains and reinforcement directions. The implementation is a lower bound formulation, resulting in a convex optimisation problem that consists of a number of linear constraints from the equilibrium equations and a number of convex non-linear constraints from the yield criteria...

  4. Steel fiber reinforced concrete behavior, modelling and design

    CERN Document Server

    Singh, Harvinder

    2017-01-01

    This book discusses design aspects of steel fiber-reinforced concrete (SFRC) members, including the behavior of the SFRC and its modeling. It also examines the effect of various parameters governing the response of SFRC members in detail. Unlike other publications available in the form of guidelines, which mainly describe design methods based on experimental results, it describes the basic concepts and principles of designing structural members using SFRC as a structural material, predominantly subjected to flexure and shear. Although applications to special structures, such as bridges, retaining walls, tanks and silos are not specifically covered, the fundamental design concepts remain the same and can easily be extended to these elements. It introduces the principles and related theories for predicting the role of steel fibers in reinforcing concrete members concisely and logically, and presents various material models to predict the response of SFRC members in detail. These are then gradually extended to d...

  5. Mixed Consolidation Solution for a Reinforced Concrete Structure

    Science.gov (United States)

    Lute, M.

    2016-06-01

    During the last years, reinforced concrete structures become subject for rehabilitation due to two factors: their long life span and large change in norms that leaded to a large increase of seismic loads in Eastern Europe. These lead to a necessity for rehabilitation of existing building stock in order to use them during their entire life span at the maximum potential. The present paper proposes a solution for rehabilitation for three reinforced concrete building of a hospital, that consumed a half of their life span and do not correspond anymore to present norms. The chosen solution is a combination between CFRP rehabilitation and increase of structural elements cross section in order to achieve the stiffness balance in the structure nodes that is required by present norms. As a further matter, correction in stiffness of local elements diminished the lateral drifts of the structure and improved the global seismic response of the building.

  6. Quantitative approach for damage detection of reinforced concrete frames

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The objective of this paper is to provide an analytical basis for the quantitative evaluation of damage to a reinforced concrete structure based on the vibration data obtained by using the damage detection technique. A partial reinforced concrete system of a weak beam/strong column moment frame is chosen as an example. A pushover analysis is carried out in order to numerically examine both the story shear-relative displacement characteristics and the associated damage level. In the analysis, a two dimensional nonlinear finite element analysis is employed considering several constitutive models. As a result, the degradation of the stiffness at the damaged story is characterized in association with the story relative displacement. It is also pointed out that the rotation angle of the column-base is highly correlated with the story relative displacement. Based on the analytical findings, quantitative approaches for a structural health monitoring system are suggested considering both the current sensor technologies and those available in the future.

  7. Experimental analysis of reinforced concrete columns strengthened with Self-Compacting concrete

    Directory of Open Access Journals (Sweden)

    M. Y. M. Omar

    Full Text Available This paper presents the results of reinforced concrete columns strengthened by addition of a self-compacting concrete overlay at the compressed and at the tensioned face of the member, with and without addition of longitudinal steel bars. Eight columns were submit- ted to loading with an initial eccentricity of 60 mm . These columns had 120 mm x 250 mm of rectangular cross section, 2000 mm in length and four longitudinal reinforcement steel bars with 10 mm in diameter. Reference columns P1 and P2 were tested to failure without any type of rehabilitation. Columns P3 to P8 were loaded to a predefined load (close to the initial yield point of tension reinforce- ment, then unloaded and strengthened for a subsequent test until failure. Results showed that the method of rehabilitation used was effective, increasing the loading capacity of the strengthened pieces by 2 to 5 times the ultimate load of the reference column.

  8. Punching strength of reinforced concrete flat slabs without shear reinforcement

    Directory of Open Access Journals (Sweden)

    P. V. P. Sacramento

    Full Text Available Punching strength is a critical point in the design of flat slabs and due to the lack of a theoretical method capable of explaining this phenomenon, empirical formulations presented by codes of practice are still the most used method to check the bearing capacity of slab-column connections. This paper discusses relevant aspects of the development of flat slabs, the factors that influence the punching resistance of slabs without shear reinforcement and makes comparisons between the experimental results organized in a database with 74 slabs carefully selected with theoretical results using the recommendations of ACI 318, EUROCODE 2 and NBR 6118 and also through the Critical Shear Crack Theory, presented by Muttoni (2008 and incorporated the new fib Model Code (2010.

  9. Study of the stress-strain state of compressed concrete elements with composite reinforcement

    Directory of Open Access Journals (Sweden)

    Bondarenko Yurii

    2017-01-01

    Full Text Available The efficiency analysis of the application of glass composite reinforcement in compressed concrete elements as a load-carrying component has been performed. The results of experimental studies of the deformation-strength characteristics of this reinforcement on compression and compressed concrete cylinders reinforced by this reinforcement are presented. The results of tests and mechanisms of sample destruction have been analyzed. The numerical analysis of the stress-strain state has been performed for axial compression of concrete elements with glasscomposite reinforcement. The influence of the reinforcement percentage on the stressed state of a concrete compressed element with the noted reinforcement is estimated. On the basis of the obtained results, it is established that the glass-composite reinforcement has positive effect on the strength of the compressed concrete elements. That is, when calculating the load-bearing capacity of such structures, the function of composite reinforcement on compression should not be neglected.

  10. Collapse mechanisms and strength prediction of reinforced concrete pile caps

    DEFF Research Database (Denmark)

    Jensen, Uffe G.; Hoang, Linh Cao

    2012-01-01

    This paper describes an upper bound plasticity approach for strength prediction of reinforced concrete pile caps. A number of collapse mechanisms are identified and analysed. The procedure leads to an estimate of the load-carrying capacity and an identification of the critical collapse mechanism....... It is argued that the upper bound approach may be a useful complement to the widely used lower bound strut-and-tie method. Especially when dealing with strength assessment of existing structures....

  11. Fatigue testing of reinforced-concrete steel bars

    Science.gov (United States)

    Maropoulos, S.; Fasnakis, D.; Voulgaraki, Ch; Papanikolaou, S.; Maropoulos, A.; Antonatos, A.

    2016-11-01

    A number of low-cycle fatigue tests were conducted on reinforced-concrete steel bars of various diameters to study their behaviour under axial loading according to EN 10080 and EN 1421-3. Scanning electron microscopy was used to study the specimen fracture surfaces. The problems faced during testing are presented and a specimen preparation method is described that will aid researchers on fatigue testing to obtain accurate test results and save on material and time.

  12. Cost analysis of reinforced concrete slabs and columns

    OpenAIRE

    Spuś, Piotr

    2013-01-01

    The construction industry is increasingly looking for solutions that are both simple and effective and that provide cost savings, speed and flexibility of execution. Two-way slabs are a form of construction unique to reinforced concrete comparing with the other major structural materials. It is an efficient, economical, and widely used structural system. The present dissertation aims to analyze and compare costs between four types of slabs: waffle slab with recuperate molds, flat slabs wit...

  13. Thermal analysis of reinforced concrete beams and frames

    Directory of Open Access Journals (Sweden)

    Essam H. El-Tayeb

    2017-04-01

    The obtained results of the studied cases reveal that material modeling of reinforced concrete beams and frames plays a major role in how these structures react to temperature variation. Cracking contributes to the release of significant portion of temperature restrain and in some cases this restrain is almost eliminated. The response of beams and frames deviates significantly based on the temperature gradient, linear or nonlinear; hence, the nonlinear temperature gradient which is the realistic profile is important to implement in the analysis.

  14. Assessment of Commercial Corrosion Inhibiting Admixtures for Reinforced Concrete

    OpenAIRE

    Brown, Michael Carey

    1999-01-01

    Corrosion of reinforcing steel in concrete exposed to chloride-laden environments is a well-known and documented phenomenon. The need for cost effective systems for protection against corrosion has become increasingly clear since the first observations of severe corrosion damage to interstate bridges in the 1960's. As one potential solution to the mounting problem of corrosion deterioration of structures, corrosion-inhibiting admixtures have been researched and introduced into service. ...

  15. Interfacial chemistry of zinc anodes for reinforced concrete structures

    Energy Technology Data Exchange (ETDEWEB)

    Covino, B.S. Jr.; Bullard, S.J.; Cramer, S.D.; Holcomb, G.R. [Dept. of Energy, Albany, OR (United States). Albany Research Center; McGill, G.E.; Cryer, C.B. [Oregon Dept. of Transportation, Salem, OR (United States); Stoneman, A. [International Lead Zinc Research Organization, Research Triangle Park, NC (United States); Carter, R.R. [California Dept. of Transportation, Sacramento, CA (United States)

    1997-12-01

    Thermally-sprayed zinc anodes are used in both galvanic and impressed current cathodic protection systems for reinforced concrete structures. The Albany Research Center, in collaboration with the Oregon Department of Transportation, has been studying the effect of electrochemical aging on the bond strength of zinc anodes for bridge cathodic protection systems. Changes in anode bond strength and other anode properties can be explained by the chemistry of the zinc-concrete interface. The chemistry of the zinc-concrete interface in laboratory electrochemical aging studies is compared with that of several bridges with thermal-sprayed zinc anodes and which have been in service for 5 to 10 years using both galvanic and impressed current cathodic protection systems. The bridges are the Cape Creek Bridge on the Oregon coast and the East Camino Undercrossing near Placerville, CA. Also reported are interfacial chemistry results for galvanized steel rebar from the 48 year old Longbird Bridge in Bermuda.

  16. Advanced modelling of concrete deterioration due to reinforcement corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Isgor, O.B. [Carleton Univ., Dept. of Civil and Environmental Engineering, Ottawa, Ontario (Canada); Razaqpur, A.G. [McMaster Univ., Dept. of Civil Engineering, Hamilton, Ontario (Canada)

    2006-06-15

    A comprehensive model is presented for predicting the rate of steel corrosion in concrete structures and the consequent formation and propagation of cracks around the steel reinforcement. The corrosion model considers both the initiation and the propagation stages of corrosion. Processes commencing in the initiation stage, such as the transport of chloride ions and oxygen within the concrete and variation in temperature and moisture, are assumed to continue in the propagation stage while active corrosion is occurring contemporaneously. This allows the model to include the effects of changes in exposure conditions on the corrosion rate and the effects of the corrosion reactions on the transport properties of concrete. The corrosion rates are calculated by applying the finite-element solution of the Laplace equation for electrochemical potential, with appropriate boundary conditions. Because these boundary conditions are nonlinear, a nonlinear solution algorithm is used. The results of the analysis are compared with available test data, and the comparison is found to be satisfactory. (author)

  17. ANALYSIS OF EXPOSURE OF REINFORCED CONCRETE BUILDINGS TO TEMPERATURE LOADS

    Directory of Open Access Journals (Sweden)

    Mkrtychev Oleg Vartanovich

    2012-10-01

    Full Text Available The co-authors consider the problem of analysis of building structures in respect of combined effects of forces and temperatures. Results of fire tests of reinforced concrete walls and slabs are presented. Overview of the analysis of the fire resistance of reinforced-concrete buildings is also provided. As a result of the research, numerical solutions were obtained in respect of deflections, stresses, deformations and internal forces arising in a reinforced concrete bearing wall and plate exposed to a combination of forces and thermal loads. Comparative analysis of the experimental data and the results of the numerical solution was performed. The conclusion is that the experimental data are in good fit to the results of the numerical solution. Overall limit state of the monolithic building under consideration in terms of its fire resistance means its failure as a result of collapse. The limit state value is equal to 60; therefore, it is equal to 60 minutes. This value, if considered in respect of separate bearing elements, fits the fire resistance limit of buildings of Grade III (Fire Resistance that is equal to 45. Evidently, assurance of higher fire resistance limits of the building under consideration requires special fire safety actions to be applied.

  18. Bond behaviour of GFRP reinforced geopolymer cement concrete

    Directory of Open Access Journals (Sweden)

    Hailu Tekle Biruk

    2017-01-01

    Full Text Available Bond plays a key role in the performance of reinforced concrete structures. Glass fibre reinforced polymer (GFRP reinforcing bar and Geopolymer cement (GPC concrete are promising alternative construction materials for steel bars and Ordinary Portland Cement (OPC concrete respectively. In this study, the bond behaviour between these two materials is investigated by using beam-end specimen tests. The bond behaviour of 15.9 mm diameter sand-coated GFRP bar was investigated. An embedment length of six and nine times the bar diameter were used. The free end and the loaded end bond-slip-relationships, the bond failure mode and the average bond stress were used to analyse each of the specimens. Additionally, the distribution of tensile and bond stress along the embedment length was investigated by installing strain gauges along the embedment length in some of the specimens. Test results indicate that a significant difference exists between the free end and loaded end bond-slip curves, which is due to the lower elastic modulus of the GFRP bars. Furthermore, it was found that the tensile and bond stress distribution along the embedment length is nonlinear and the nonlinearity changes with the load.

  19. Seismic Behaviour of Reinforced Concrete Slit Shear Walls Energy Dissipators

    Directory of Open Access Journals (Sweden)

    Sergiu Băetu

    2010-01-01

    Full Text Available The types of slit walls energy dissipators, from monolith or precast reinforced concrete, proposed by researchers and the seismic behaviour of these types of walls are described. The overall ductility of the structure increases, considering the energy dissipation solutions proposed by the researchers of the reinforced concrete walls, resulting a supplementary safety for the structure. The objective of these solutions is to create an ideal structure for tall multi-storey buildings, that behaves as a rigid structure at low seismic action and turns into a flexible one in case of a high intensity earthquake action. The solutions for increasing ductility proposed in this paper are viable and easily to use in constructions practice. For the analysis of slit wall, the researchers used a series of analytical calculation methods, among the most important being the equivalent frame method and the finite element method, both presented s. 3 of the paper. The researchers concluded that by using this calculations methods, the dynamic behaviour of the reinforced concrete slit walls can be simulated very accurate and realistic.

  20. Process of cracking in reinforced concrete beams (simulation and experiment

    Directory of Open Access Journals (Sweden)

    I. N. Shardakov

    2016-10-01

    Full Text Available The paper presents the results of experimental and theoretical investigations of the mechanisms of crack formation in reinforced concrete beams subjected to quasi-static bending. The boundary-value problem has been formulated in the framework of brittle fracture mechanics and solved using the finite-element method. Numerical simulation of the vibrations of an uncracked beam and a beam with cracks of different size serves to determine the pattern of changes in the spectrum of eigenfrequencies observed during crack evolution. A series of sequential quasi-static 4-point bend tests leading to the formation of cracks in a reinforced concrete beam were performed. At each loading step, the beam was subjected to an impulse load to induce vibrations. Two stages of cracking were detected. During the first stage the nonconservative process of deformation begins to develope, but has not visible signs. The second stage is an active cracking, which is marked by a sharp change in eingenfrequencies. The boundary of a transition from one stage to another is well registered. The vibration behavior was examined for the ordinary concrete beams and the beams strengthened with a carbon-fiber polymer. The obtained results show that the vibrodiagnostic approach is an effective tool for monitoring crack formation and assessing the quality of measures aimed at strengthening concrete structures

  1. Blast impact behaviour of concrete with different fibre reinforcement

    Directory of Open Access Journals (Sweden)

    Drdlová Martina

    2015-01-01

    Full Text Available The paper summarizes the results of the development of special concrete intended for the explosion resistance applications, with the emphasis on minimal secondary fragments formation at the explosion. The fine-grained concrete matrix has been reinforced by various types of short dispersed fibers (metallic, mineral and polymer of different sizes and by their combination and the effect of the fibre reinforcement on the physico-mechanical properties and blast resistance was observed. The concrete prism specimens have been subjected to the determination of mechanical parameters (compressive and flexural strength at quasi-static load. The blast tests were conducted on the slab specimens prepared from selected mixtures. The material characteristics and explosion test data have been used for numerical investigation, which defined the optimal wall composition and dimensions of the concrete element which should resist the explosion defined by type, size, weight and placement of the blast. In the next step the test elements resistance was verified by real explosion test.

  2. Cathodic protection of reinforced concrete structures in the Netherlands - Experience and developments: Cathodic protection of concrete - 10 years experience

    NARCIS (Netherlands)

    Polder, R.B.

    1998-01-01

    Cathodic protection (CP) of reinforcing steel in concrete structures has been used successfully for over 20 years. CP is able to stop corrosion in a reliable and economical way where chloride contamination has caused reinforcement corrosion and subsequent concrete damage. To new structures where cor

  3. Cathodic protection of reinforced concrete structures in the Netherlands - Experience and developments: Cathodic protection of concrete - 10 years experience

    NARCIS (Netherlands)

    Polder, R.B.

    1998-01-01

    Cathodic protection (CP) of reinforcing steel in concrete structures has been used successfully for over 20 years. CP is able to stop corrosion in a reliable and economical way where chloride contamination has caused reinforcement corrosion and subsequent concrete damage. To new structures where

  4. Retrofitting Of Reinforced Concrete Column by Steel Jacketing

    Directory of Open Access Journals (Sweden)

    Abhishek Jodawat

    2016-07-01

    Full Text Available Reinforced concrete structures often require strengthening to increase their capacity to sustain additional loads, due to change in use that resulted in additional live loads, deterioration of the load carrying elements, design errors, construction problems during erection, aging of structure itself or upgrading to confirm to current code requirements. These situations may require additional concrete elements or the entire concrete structure to be strengthened, repaired or retrofitted. Common methods for strengthening columns include concrete jacketing, fiber reinforced polymer (FRP jacketing and steel jacketing. All these methods have been shown to effectively increase the axial load capacity of columns. The experimental study was carried out on RC column on designed and detailed using IS 456:2000 provisions. The concrete mix design being performed after conducting numerous material test and cube test to validate expected strength as per specified grade of concrete. The trial testing conducted to estimate load at 1st crack and failure load for normal RC column with capturing displacement using dial gauges at regular load increment in UTM. The loading conditions are decided based on failure load to induce cracks in column under 85% loading of the failure one. In all fifteen specimen casted and tested with three samples for failure load estimation, three samples each for plate jacketing & angle battening system and three samples each for plate jacketing & angle battening with column preloaded to 85% of its failure load. The angle batten system proves to be better compared to full plate retrofitting in terms of load carrying capacity and enhancing confinement effect.

  5. 77 FR 71631 - Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and...

    Science.gov (United States)

    2012-12-03

    ... COMMISSION Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and Ukraine; Scheduling of Full Five-Year Reviews Concerning the Antidumping Duty Orders on Steel Concrete...) to determine whether revocation of the antidumping duty orders on steel concrete reinforcing bar from...

  6. 78 FR 73838 - Steel Concrete Reinforcing Bar From Turkey: Postponement of Preliminary Determination in the...

    Science.gov (United States)

    2013-12-09

    ... International Trade Administration Steel Concrete Reinforcing Bar From Turkey: Postponement of Preliminary... Department of Commerce (the Department) initiated a countervailing duty investigation on steel concrete... December 16, 2013.\\3\\ \\1\\ See Steel Concrete Reinforcing Bar from Turkey: Initiation of Countervailing Duty...

  7. Bond of reinforcing bars in self-compacting steel fiber reinforced concrete

    NARCIS (Netherlands)

    Schumacher, P.; Bigaj-van Vliet, A.J.; Braam, C.R.; Uijl, J.A. den; Walraven, J.C.

    2002-01-01

    Pull-out tests were performed on 10 mm diameter ribbed bars embedded along three times the bar diameter in 200 mm cubes made of plain and steel fiber reinforced concrete (SFRC) of normal strength (B45). The fiber content was 60 and 120 kg/m3, respectively, the aspect ratio of the fibers was 45 and 8

  8. Numerical Study of FRP Reinforced Concrete Slabs at Elevated Temperature

    Directory of Open Access Journals (Sweden)

    Masoud Adelzadeh

    2014-02-01

    Full Text Available One-way glass fibre reinforced polymer (GFRP reinforced concrete slabs at elevated temperatures are investigated through numerical modeling. Serviceability and strength requirements of ACI-440.1R are considered for the design of the slabs. Diagrams to determine fire endurance of slabs by employing “strength domain” failure criterion are presented. Comparisons between the existing “temperature domain” method with the more representative “strength domain” method show that the “temperature domain” method is conservative. Additionally, a method to increase the fire endurance of slabs by placing FRP reinforcement in two layers is investigated numerically. The amount of fire endurance gained by placing FRP in two layers increases as the thickness of slab increases.

  9. REVERSAL CYCLIC LOADING TEST OF REINFORCED CONCRETE COLUMN WITH HIGH DENSITY LONGITUDINAL REINFORCEMENT CONFINED BY SPIRAL REINFORCEMENT

    Science.gov (United States)

    Ohba, Mitsuaki; Sato, Akiko; Ishibashi, Tadayoshi

    In case of that column diameter is restricted by the narrow construction space, Concrete filled steel tube column is used. Authors developed new arrangement of bars that the range of longitudinal reinforcement ratio is from 14.8% to 24.7% and the longitudinal reinforcements are reinforced by spiral reinforcement. For the confirmation of the damage form and the deformation performance of the column with new bar arrangement at the earthquake, static reversal cyclic loading test was carried out. The parameters are longitudinal reinforcement ratio, shear span ratio and strength ratio. As the result, the damage form showed different trends due to longitudinal reinforcement ratio, shear span ratio and flexural strength and shear strength ratio. And specimens with the new bar arrangement had a good ductility with rotation angle of the column more than 1/10 and no rapid decline of strength. And, it is possible to evaluate ultimate bending capacity by considering the damage situation at maximum load.

  10. Theoretical and numerical analysis of reinforced concrete beams with confinement reinforcement

    Directory of Open Access Journals (Sweden)

    R. G. Delalibera

    Full Text Available This paper discusses the use of confinement in over-reinforced concrete beams. This reinforcement consists of square stirrups, placed in the compression zone of the beam cross-section, in order to improve its ductility. A parametric numerical study is initially performed, using a finite element computational program that considers the material nonlinearities and the confinement effect. To investigate the influence of the transverse reinforcing ratio on the beam ductility, an experimental program was also conducted. Four over-reinforced beams were tested; three beam specimens with additional transverse reinforcement to confine the beams, and one without it. All specimens were fabricated with a concrete designed for a compressive strength of 25 MPa. The experimental results show that the post-peak ductility factor is proportional to the confining reinforcement ratio, however the same is not observed for the pre-peak ductility factor, which varied randomly with changes in the confining reinforcement ratio. It was also observed from the experiments that the confinement effect tends to be smaller close to the beam neutral axis.

  11. Marine durability of 23-year old reinforced concrete beams

    Energy Technology Data Exchange (ETDEWEB)

    Mohammed, T. U. [NEWJEC Inc., Technology Development Dept., Osaka (Japan); Otsuki, N. [Tokyo Inst. of Technology (Japan); Hisada, M. [Niigata Univ., (Japan); Hamada, H. [Ministry of Transport, Port and Harbor Research Inst., Yokosuka (Japan)

    2000-07-01

    Results of a study concerning the durability of 23-year old reinforced concrete beams exposed to marine tidal and atmospheric environments are presented. The study focused on the corrosion of steel bars with respect to orientation in concrete, carbonation and chloride ion-induced corrosion, quantitative evaluation of electrochemical data and the influence of stirrups on macrocell formation. Experimental work included half cell potential, polarization resistance, solution resistance investigations, chloride ion profile and carbonation depth measurements, microscopic observations of steel-concrete interfaces, and visual inspection of steel bars corrosion. Results showed that chloride ion-induced corrosion was significantly influenced by the orientation of the steel bars in the concrete. Macrocell corrosion was found to be the governing process of corrosion in atmospheric environment, while stirrups played an important role in macrocell formation. Assuming the use of a suitable pit concentration, polarization data was considered to provide an acceptable, although inexact, estimate of the depth of corrosion. Peak chloride ion concentration was not observed at the concrete surface but at some distance below the surface, probably due to the effect of wetting and drying cycles. 8 refs., 9 tabs., 11 figs.

  12. Seismic retrofitting of reinforced concrete frame structures using GFRP-tube-confined-concrete composite braces

    Science.gov (United States)

    Moghaddasi B., Nasim S.; Zhang, Yunfeng; Hu, Xiaobin

    2012-03-01

    This paper presents a new type of structural bracing intended for seismic retrofitting use in framed structures. This special composite brace, termed glass-fiber-reinforced-polymer (GFRP)-tube-confined-concrete composite brace, is comprised of concrete confined by a GFRP tube and an inner steel core for energy dissipation. Together with a contribution from the GFRP-tube confined concrete, the composite brace shows a substantially increased stiffness to control story drift, which is often a preferred feature in seismic retrofitting. An analysis model is established and implemented in a general finite element analysis program — OpenSees, for simulating the load-displacement behavior of the composite brace. Using this model, a parametric study of the hysteretic behavior (energy dissipation, stiffness, ductility and strength) of the composite brace was conducted under static cyclic loading and it was found that the area ratio of steel core to concrete has the greatest influence among all the parameters considered. To demonstrate the application of the composite brace in seismic retrofitting, a three-story nonductile reinforced concrete (RC) frame structure was retrofitted with the composite braces. Pushover analysis and nonlinear time-history analyses of the retrofitted RC frame structure was performed by employing a suite of 20 strong ground motion earthquake records. The analysis results show that the composite braces can effectively reduce the peak seismic responses of the RC frame structure without significantly increasing the base shear demand.

  13. Flexural strengthening of Reinforced Concrete (RC) Beams Retrofitted with Corrugated Glass Fiber Reinforced Polymer (GFRP) Laminates

    Science.gov (United States)

    Aravind, N.; Samanta, Amiya K.; Roy, Dilip Kr. Singha; Thanikal, Joseph V.

    2015-01-01

    Strengthening the structural members of old buildings using advanced materials is a contemporary research in the field of repairs and rehabilitation. Many researchers used plain Glass Fiber Reinforced Polymer (GFRP) sheets for strengthening Reinforced Concrete (RC) beams. In this research work, rectangular corrugated GFRP laminates were used for strengthening RC beams to achieve higher flexural strength and load carrying capacity. Type and dimensions of corrugated profile were selected based on preliminary study using ANSYS software. A total of twenty one beams were tested to study the load carrying capacity of control specimens and beams strengthened with plain sheets and corrugated laminates using epoxy resin. This paper presents the experimental and theoretical study on flexural strengthening of Reinforced Concrete (RC) beams using corrugated GFRP laminates and the results are compared. Mathematical models were developed based on the experimental data and then the models were validated.

  14. Interface study of fiber reinforced concrete

    Directory of Open Access Journals (Sweden)

    Pacios, A.

    1997-12-01

    Full Text Available In a composite material that uses fibers as reinforcement, the breakage of the matrix is produced jointly with the separation of the fiber from the matrix. The mechanical behavior of the interface describes how fibers can work stabilizing the cracking process. The interface is the medium that puts the fiber on load, being the mechanical behavior of the interface and the strength of the fiber two important parameters to consider to characterize the general behavior of the composite. The present work studies the effect of several parameters on the behavior of the interface. Those parameters are the type of fiber, its geometry and dimension and the modified matrix and loading rate. An experimental technique was designed to allow testing the same set-up for pull-out tests in a quasistatic machine and Charpy pendulum. Modifications of the matrix by adding a mineral admixture improve the behavior of the interface as much as a 100%. It has been observed that combining the two actions, an improved matrix with crimped fibers, the type of failure can be modified. In this new type of failure, the fiber breaks consequently toughness decreases. Other parameters, as the loading rate and inclination of the fiber also affect the behavior of the interface.

    En un material compuesto que utiliza fibras como refuerzo, la rotura de la matriz se produce conjuntamente con la separación de la fibra de la matriz, por lo que el comportamiento mecánico de la interfase describe hasta que punto las fibras pueden trabajar como estabilizadores en el proceso defisuración. La interfase es el medio que pone en carga a la fibra y, por ello, la resistencia mecánica de la interfase y de la fibra son dos parámetros importantes a considerar para caracterizar el comportamiento general del composite. Este trabajo investiga el efecto de la variación del tipo de fibra, geometría y dimensión de las mismas y las modificaciones de la matriz y la velocidad de desplazamiento

  15. Improvement in reinforcing bond strength in reinforced concrete with self-repairing chemical adhesives

    Science.gov (United States)

    Dry, Carolyn M.

    1997-05-01

    Self-healing concretes have embedded adhesives which are released from hollow fibers inside the concrete when and where cracking of the matrix and the fibers occurs. It was found that the adhesive improves the strength of the cracked portions of the concrete and increases its ability to deflect under load. Structural materials subjected to dynamic events such as earthquakes and impacts can have improved response by the noise of adhesive type which can impart improved damping, lateral stiffness, or deflection. Testing also assessed the improvement of the bond strength in structures. In laboratory tests the internal adhesive repair system improved the bond between the reinforcing steel and the concrete to prevent pullout failure or debonding at the interface.

  16. es on Strength Characteristics of Pond Ash Replaced Fibre Reinforced Pavement Quality Concrete

    Directory of Open Access Journals (Sweden)

    Anand G Patil

    2015-08-01

    Full Text Available Energy consumption and generation is increasing day by day due to rapid industrialization & urbanization. A major portion of the energy is generated by Thermal Power Plants. Pond ash (PA and other by-products from these plants are disposed in large quantities. Pond ash utilization helps to reduce the consumption of natural resources. Hence there is scope for using Pond ash as Fine Aggregate (FA. Use of alternative material in concrete such as industrial by-products like Coal Ash (Fly Ash and Pond Ash is eco-friendly. This study reports the results of experimental studies carried out on the use of Pond ash as Fine Aggregate (FA in concrete with and without fibre reinforcement. The properties of Pond Ash were compared to the standard sand. The pond ash added by weight is 10%,20%,30%,40%,50% and 60% respectively as replacement of FA in concrete and 2% low tensile steel fibre was used for reinforcement. Experiments carried out indicate that Pond ash as partial replacement of sand has beneficial effect on the mechanical properties. The strength properties are determined for various percentages (10-60% of replacement of Fine Aggregate with Pond ash with and without fibre reinforcement. The test results indicate that the optimum PA replacement is 20% for both the cases.

  17. Resistance of reinforced concrete beams in explosive charges

    Directory of Open Access Journals (Sweden)

    Roman Krzewiński

    2016-12-01

    Full Text Available The paper presents an analysis of the dynamic interaction on reinforced concrete beams, caused by the outbreak of not-direct contact with the design. Depending on the distance of the source of the outbreak, the structure may be loaded with gas stream postexplosion or air shock wave. The impact of such influence on the reinforced concrete beam of a constant cross-section and small transverse dimensions compared with their length was assessed. For the beams located in the closer zone, there were evaluated the parameters of the destructive action of explosions limit case, in which the concrete chipping occurs at a length of at least the length of the buckling of steel rods. In case of loading of beams with air shock wave, using literature data, they determined the way of evaluating equivalent static load at which the boundary elastic deflection of beams occurs. The above analysis is shown by the example calculation, which sets the minimum length of the buckling of steel bars in the beam bending.[b]Keywords:[/b] civil engineering, the dynamics of the explosion, the noncontact loads, dynamic loads, reflectance

  18. Enhancement of shear strength and ductility for reinforced concrete wide beams due to web reinforcement

    Directory of Open Access Journals (Sweden)

    M. Said

    2013-12-01

    Full Text Available The shear behavior of reinforced concrete wide beams was investigated. The experimental program consisted of nine beams of 29 MPa concrete strength tested with a shear span-depth ratio equal to 3.0. One of the tested beams had no web reinforcement as a control specimen. The flexure mode of failure was secured for all of the specimens to allow for shear mode of failure. The key parameters covered in this investigation are the effect of the existence, spacing, amount and yield stress of the vertical stirrups on the shear capacity and ductility of the tested wide beams. The study shows that the contribution of web reinforcement to the shear capacity is significant and directly proportional to the amount and spacing of the shear reinforcement. The increase in the shear capacity ranged from 32% to 132% for the range of the tested beams compared with the control beam. High grade steel was more effective in the contribution of the shear strength of wide beams. Also, test results demonstrate that the shear reinforcement significantly enhances the ductility of the wide beams. In addition, shear resistances at failure recorded in this study are compared to the analytical strengths calculated according to the current Egyptian Code and the available international codes. The current study highlights the need to include the contribution of shear reinforcement in the Egyptian Code requirements for shear capacity of wide beams.

  19. Failure mode classification of reinforced concrete column using Fisher method

    Institute of Scientific and Technical Information of China (English)

    戚永乐; 韩小雷; 季静

    2013-01-01

    In order to apply the performance-based seismic design, an engineer must first find out whether the column is expected to fail in shear before or after flexural yielding. According to column failure characteristics and failure mode of reinforced concrete column, the UW-PEER structure performance database was discussed and analyzed. In order to investigate the relevance of failure mode and factors such as longitudinal reinforcement ratio, transverse reinforcement ratio, hoop spacing to depth ratio, aspect ratio, shearing resistance demand to shear capacity ratio and axial load ratio, Fisher’s discriminant analysis(FDA) of the above factors was carried out. A discriminant function was developed to identify column failure mode. Results show that three factors, i.e., Vp /Vn, hoop spacing to depth ratio and aspect ratio have important influence on the failure mode. The failure mode has less to do with longitudinal reinforcement ratio, transverse reinforcement ratio and axial load ratio. Through using these three factors and the model proposed, over 85.6% of the original grouped cases were correctly classified. The value of coefficient of Vp /Vn is the largest, which means that discriminant equation is most sensitive to the shearing resistance demand to shear capacity ratio.

  20. Improvement of impact-resistance of a nuclear containment building using fiber reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Se-Jin, E-mail: conc@ajou.ac.kr [Ajou University, 206, World cup-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do 16499 (Korea, Republic of); Jin, Byeong-Moo [DAEWOO E& C, Institute of Construction Technology, 20, Suil-ro 123beon-gil, Jangan-gu, Suwon-si, Gyeonggi-do 16297 (Korea, Republic of)

    2016-08-01

    Highlights: • Impact-resistance of a structure can be improved by fiber reinforced concrete (FRC). • Material modeling of FRC is incorporated into finite element analysis of a structure. • A new index for impact-resistance is proposed based on plastic dissipation energy. • A nuclear power plant made of FRC shows improved resistance against aircraft crashes. - Abstract: Since the act of terrorism that occurred in the USA on September 11, 2001, the protection of nuclear power plants against large commercial aircraft crashes has been an emerging issue. Besides the verification of the safety of nuclear power plants in operation or in design, efficient methods for improving the impact-resistance of these structures have been investigated. Fiber reinforced concrete (FRC) has been generally accepted as an effective material for this purpose. In particular, FRC has been developed to improve the tensile behavior of concrete such as tensile strength, ductility and toughness. One of the main fields of application of FRC can be found in blast-protective or blast-resistant concrete structures. It is expected, therefore, that safety-related structures in a nuclear power plant can also be effectively protected from external blast, aircraft crash, etc. by applying FRC. In order to analytically verify the effect on structural behavior of applying FRC, the particular material properties of FRC should be incorporated into the material modeling of a structural analysis program. This study investigates the mathematical modeling of FRC, which represents various aspects of material behavior. Two numerical examples are provided to show the improved impact-resistance of a nuclear containment building that is expected when applying FRC in comparison with ordinary concrete. The analysis results show that the displacement decreases by 43–67% while the impact-resistance increases by 40–82%, depending on a fiber type.

  1. Strengthening Reinforced Concrete Beams with CFRP and GFRP

    Directory of Open Access Journals (Sweden)

    Mehmet Mustafa Önal

    2014-01-01

    Full Text Available Concrete beams were strengthened by wrapping the shear edges of the beams twice at 45° in opposite directions by either carbon fiber reinforced polymer (CFRP or glass fiber reinforced polymer (GFRP. The study included 3 CFRP wrapped beams, 3 GFRP wrapped beams, and 3 control beams, all of which were 150 × 250 × 2200 mm and manufactured with C20 concrete and S420a structural steel at the Gazi University Technical Education Faculty labs, Turkey. Samples in molds were cured by watering in the open air for 21 days. Four-point bending tests were made on the beam test specimens and the data were collected. Data were evaluated in terms of load displacement, bearing strength, ductility, and energy consumption. In the CFRP and GFRP reinforced beams, compared to controls, 38% and 42%, respectively, strength increase was observed. In all beams, failure-flexural stress occurred in the center as expected. Most cracking was observed in the flexural region 4. A comparison of CFRP and GFRP materials reveals that GFRP enforced parts absorb more energy. Both materials yielded successful results. Thicker epoxy application in both CFRP and GFRP beams was considered to be effective in preventing break-ups.

  2. Correlations Between Mechanical Properties of Steel Fiber Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Carrillo Julián

    2013-06-01

    Full Text Available Tension strength and post-cracking deformation capacities that exhibits steel fiber reinforced concrete (SFRC stimulate its use in elements governed by shear deformations. Aimed at developing design aids that promote the use of SFRC as web shear reinforcement of concrete walls for low-rise economic housing (LEH, an experimental study for describing the mechanical properties of SFRC was carried out. The experimental program included testing of 128 cylinder- and beam-type specimens. According to requirements specified by ACI-318, to thickness of walls used in LEH, and to results of previous studies, three Dramix fibers with length-diameter ratios of 55, 64 and 80 were selected. Fiber dosage was expressed in terms of the minimum fiber dosage specified by ACI-318 for replacing the minimum area of conventional shear reinforcement in beams (60 kg/m3. Therefore, five dosages were used: 0, 40, 45, 60 and 75 kg/m3. Mechanical properties of SFRC under compressive, tensile and flexural stresses were evaluated in this study. Based on trends of experimental results, numerical correlations for estimating both basic mechanical properties and properties that describe flexural performance of SFRC are proposed.

  3. Evaluation of Concrete Consolidation: DSS-35 Antenna Reinforced Concrete Pedestal, Canberra Deep Space Communications Complex, Australia

    Science.gov (United States)

    Saldua, B. P.; Dodge, E. C.; Kolf, P. R.; Olson, C. A.

    2016-02-01

    Antenna structures for the Deep Space Network track spacecraft that are millions of miles away. Therefore, these structures have tight specifications for translation, rotation, and differential settlement. This article presents several nondestructive test methods that were used to evaluate, locate, and repair imperfections in the reinforced concrete pedestal that supports the DSS-35 antenna structure. These methods include: (1) impulse response (IR), (2) ultrasonic shear-wave tomography (MIRA), and (3) ground-penetrating radar (GPR).

  4. Neural Network Model for Moment-Curvature Relationship of Reinforced Concrete Sections

    OpenAIRE

    Bağcı, Muhiddin

    2010-01-01

    The analysis of moment-curvature relationship of reinforced concrete sections is complex due to large number of variables as well as non-linear material behavior involved. Artificial Neural Networks (ANNs) are found to be a tool capable of solving such problems. This has led to increasing use of ANN for analyzing the behavior of reinforced concrete sections. This paper reports the details of a study conducted using ANN for predicting moment-curvature relationship of a reinforced concrete sect...

  5. NATURAL CORROSION INHIBITORS FOR STEEL REINFORCEMENT IN CONCRETE — A REVIEW

    OpenAIRE

    PANDIAN BOTHI RAJA; SEYEDMOJTABA GHOREISHIAMIRI; MOHAMMAD ISMAIL

    2015-01-01

    Reinforced concrete is one of the widely used construction materials for bridges, buildings, platforms and tunnels. Though reinforced concrete is capable of withstanding a large range of severe environments including marine, industrial and alpine conditions, there are still a large number of failures in concrete structures for many reasons. Either carbonation or chloride attack is the main culprit which is due to depassivation of reinforced steel and subsequently leads to rapid steel corrosio...

  6. CALCULATION ASSESSMENT OF ANCHORAGE IN CONCRETE FOR FIBERGLASS REINFORCEMENT MANUFACTURED IN THE REPUBLIC OF BELARUS

    Directory of Open Access Journals (Sweden)

    E. Ya. Sadin

    2016-01-01

    Full Text Available The paper analyzes advantages and disadvantages of composite reinforcement while reinforcing concrete structures. Results of experimental investigations on adhesion strength of fiberglass reinforcement manufactured in the Republic of Belarus with concrete have been given in the paper. The paper contains an analysis pertaining to the influence of concrete contact diameter and length of fiberglass reinforcing bars on strength and deformability of adhesion with concrete. Failure behavior of prototypes and maximum loading that does cause breakage in adhesion of fiberglass reinforcement with the concrete have been controlled in order to study the influence of diameter and length of fiberglass reinforcing bar contact with the concrete on strength and deformability of concrete adhesion for composite reinforcement produced by various manufacturers. Displacement of non-loaded (free and loaded ends of the reinforcing bars with regard to concrete exposed face on both specimen ends has been also controlled. The experiments have shown that destruction of the prototypes occurred due to initiation of one of the following three reasons: reinforcement sliding in reference to concrete, cleaving of a protective concrete layer or breakage of composite reinforcement. Start-up moments for reinforcing bar slip in relation to the concrete have been determined with the help of two methods. The paper provides proposals for calculation assessment of anchorage in the concrete for fiberglass reinforcement manufactured by the following enterprises and companies “Stroykompozit” (Gomel, Republic of Belarus, Research and Production Company (RPC “Biznes-Kontinent” (Brest, Republic of Belarus and Private Eenterprise (PE “Minplast” (Minsk, Republic of Belarus.

  7. Investigation on Reinforced Mechanism of Fiber Reinforced Asphalt Concrete Based on Micromechanical Modeling

    Directory of Open Access Journals (Sweden)

    Ying Gao

    2017-01-01

    Full Text Available Short fibers have been widely used to prepare the fiber reinforced asphalt concrete (FRAC. However, internal interactions between fiber and other phases of asphalt concrete are unclear although experimental methods have been used to design the FRAC successfully. In this paper, numerical method was used to investigate the reinforced mechanism of FRAC from microperspective. 2D micromechanical model of FRAC was established based on Monte Carlo theory. Effects of fiber length and content on stress state of asphalt mortar, effective modulus, and viscoelastic deformation of asphalt concrete were investigated. Indirect tensile stiffness modulus (ITSM test and uniaxial creep test were carried out to verify the numerical results. Results show that maximum stress of asphalt mortar is lower compared to the control concrete when the fiber length is longer than 12 mm. Fiber reduces the stress level of asphalt mortar significantly. Fiber length has no significant influence on the effective modulus of asphalt concrete. Fiber length and content both have notable impacts on the viscoelastic performance of FRAC. Fiber length should be given more attention in the future design of FRAC except the content.

  8. Strengthening of reinforced concrete circular columns using glass fibre reinforced polymers

    Directory of Open Access Journals (Sweden)

    Manish kumar Tiwari

    2014-04-01

    Full Text Available Seismic retrofitting of reinforced concrete members vulnerable to strong earthquakes is a great problem. It has long been recognized that confinement to concrete compression members not only increase the strength but improve ductility significantly. The present study focuses on the behavior of reinforced concrete specimens strengthened using glass fiber reinforced polymer (GFRP subjected to axial compressive loading. In this study specimen of circular cross section having length to diameter ratio of 2.0 and 0.96% longitudinal reinforcement were prepared and tested for 28 days compressive strength. The specimens were wrapped with 0,2,4,6 and 8 layers of GFRP outside the surface of the specimens as confinement. The test results showed that there is a significant increase in the strength of specimen with the increase of confinement layers on the specimen. The 28 days compressive strength of specimen wrapped with 8 layers of GRRP was increased by 47% as compared to the strength of specimen without any confinement.

  9. The effects of steel fibre reinforced concrete on system ductility

    Directory of Open Access Journals (Sweden)

    Yilmaz, U. S.

    2007-03-01

    Full Text Available Steel fibre-reinforced concrete is being used extensively today in both field applications and experimental studies on concrete strength and ductility. The state of passive confinement generated by the fibre delays cracking and enhances ductility. The present paper reports on both experimental and analytical studies. In the former, a series of 16 steel-fibre reinforced concrete prismatic specimens were subjected to axial loads and the respective axial load-unit strain diagrams were subsequently plotted to determine the effect of steel fibres on reinforced concrete column ductility. Secondly, an analytical study was run to determine the additional ductility accruing to a frame system when steel fibres are included in the concrete. Analytical models were generated for 16 two-storey, single-span reinforced concrete frames. The columns in these frames were designed to the same characteristics as the specimens used in the experimental tests. Non-linear static (pushover analyses were performed for each frame to obtain load-displacement curves and determine the effect of steel fibres on reinforced concrete column ductility.El hormigón reforzado con fibra de acero se emplea actualmente tanto en obra como en los trabajos experimentales para estudiar la resistencia mecánica y ductilidad del hormigón. El estado de confinamiento pasivo producido por la fibra retrasa la fisuración y aumenta la ductilidad. El presente trabajo es de índole tanto experimental como analítica. En primer lugar, en la parte experimental se aplica una fuerza axial a 16 probetas prismáticas (160 x 160 x 840 mm de hormigón reforzado con fibra de acero para determinar su comportamiento, obteniéndose las curvas de fuerza axial-deformación unitaria correspondientes a partir de los resultados observados. A partir de una evaluación de dichos resultados experimentales, se determina el efecto que ejercen las fibras de acero sobre la ductilidad de las probetas de hormigón armado

  10. Flexural Strength Evaluation of Reinforced Concrete Members with Ultra High Performance Concrete

    Directory of Open Access Journals (Sweden)

    Baek-Il Bae

    2016-01-01

    Full Text Available Flexural strength evaluation models for steel fiber reinforced ultra high strength concrete were suggested and evaluated with test results. Suggested flexural strength models were composed of compression stress blocks and tension stress blocks. Rectangular stress block, triangular stress block, and real distribution shape of stress were used on compression side. Under tension, rectangular stress block distributed to whole area of tension side and partial area of tension side was used. The last model for tension side is realistic stress distribution. All these models were verified with test result which was carried out in this study. Test was conducted by four-point loading with 2,000 kN actuator for slender beam specimen. Additional verifications were carried out with previous researches on flexural strength of steel fiber reinforced concrete or ultra high strength concrete. Total of 21 test specimens were evaluated. As a result of comparison for flexural strength of section, neutral axis depth at ultimate state, models with triangular compression stress block, and strain-softening type tension stress block can be used as exact solution for ultra high performance concrete. For the conservative and convenient design of section, modified rectangular stress block model can be used with strain softening type tension stress block.

  11. Durability Studies on Confined Concrete using Fiber Reinforced Polymer

    Science.gov (United States)

    Ponmalar, V.; Gettu, R.

    2014-06-01

    In this study, 24 concrete cylinders with a notch at the centre were prepared. Among them six cylinders were wrapped using single and double layers of fiber reinforced polymer; six cylinders were coated with epoxy resin; the remaining cylinders were used as a control. The cylinders were exposed to wet and dry cycling and acid (3 % H2SO4) solution for the period of 120 days. Two different concrete strengths M30 and M50 were considered for the study. It is found that the strength, ductility and failure mode of wrapped cylinders depend on number of layers and the nature of exposure conditions. It was noticed that the damage due to wet and dry cycling and acid attack was severe in control specimen than the epoxy coated and wrapped cylinders.

  12. Fatigue Defect of Layer Steel Fiber Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    An experimental study is carried out on fatigue defect of layer steel fiber reinforced concrete (LSFRC). Based on experimental data,the various relation curves are given corresponding to different stress levels 0.9, 0.85, and 0.8. Furthermore, the fatigue defect degree is defined, and the strain-cycle ratio equations and defect-cycle ratio equations with the correlation coefficients very close to 1, are regressed in terms of the cubic polynomial,of which the fittings are preferable.In addition,the results show that the fatigue defect of LSFRC presents three-phase development regularity too.And in comparison with the plain concrete,the third phase of the fatigue defect of LSFRC is longer, therefore the fatigue failure of LSFRC is more ductile.The mechanism of the fatigue defect is discussed too.

  13. Analysis of reinforced concrete shells with transverse shear forces

    CERN Document Server

    Schulz, Mauro

    2013-01-01

    This research investigates the simultaneous effect of in-plane and transverse loads in reinforced concrete shells. The infinitesimal shell element is divided into layers (with triaxial behavior) that are analyzed according to the smeared rotating crack approach. The set of internals forces includes the derivatives of the in-plane components. The corresponding generalized strains are determined using an extension of the equivalent section method, valid for shells. The formulation yields through-the-thickness distributions of stresses and strains and the spatial orientation of the concrete struts. Although some simplifications are necessary to establish a practical first-order approximation, higher-order solutions could be developed. Despite the fact that constitutive matrices are not symmetric, because of the tension-softening formulation, the equilibrium and compatibility conditions are satisfied, the stiffness derivatives are explicitly calculated and the algorithms show good convergence. The formulation pre...

  14. Corrosion of steel reinforced concrete in the tropical coastal atmosphere of Havana City, Cuba

    Directory of Open Access Journals (Sweden)

    Abel Castañeda

    2013-01-01

    Full Text Available The influence of chloride deposition rate on concrete using an atmospheric corrosion approach is rarely studied in the literature. Seven exposure sites were selected in Havana City, Cuba, for exposure of reinforced concrete samples. Two significantly different atmospheric corrosivity levels with respect to corrosion of steel reinforced concrete were observed after two years of exposure depending on atmospheric chloride deposition and w/c ratio of the concrete. Changes in corrosion current are related to changes in chloride penetration and chloride atmospheric deposition. The influence of sulphur compound deposition could also be a parameter to consider in atmospheric corrosion of steel reinforced concrete.

  15. Micro-Mechanical Modeling of Fiber Reinforced Concrete

    DEFF Research Database (Denmark)

    Stang, Henrik

    1999-01-01

    of Fiber Reinforced Concrete (FRC) on the micro- the meso- as well as the macro-level, i.e. modeling aspects of fiber-matrix interaction, overall constitutive modeling and structural modeling. Emphasis is placed on the micro- and meso-aspects, however, some basic results on the macro-level are also......The paper is a contribution to the course Cement-Based Composites for the Building Industry, organized by POA Foundation for Postgraduate Studies in Civil Engineering in cooperation with Priority Programme Material Research (PPM) in the Netherlands. The text deals with mechanical modeling aspects...

  16. Design of Ultra High Performance Fiber Reinforced Concrete Shells

    DEFF Research Database (Denmark)

    Jepsen, Michael S.; Lambertsen, Søren Heide; Damkilde, Lars

    2013-01-01

    Fiber Reinforced Concrete shell. The major challenge in the design phase has been securing sufficient stiffness of the structure while keeping the weight at a minimum. The weight/stiffness issue has been investigated by means of the finite element method, to optimize the structure regarding overall......The paper treats the redesign of the float structure of the Wavestar wave energy converter. Previously it was designed as a glass fiber structure, but due to cost reduction requirements a redesign has been initiated. The new float structure will be designed as a double curved Ultra High Performance...

  17. STUDIES ON STRESS TRANSFERENCE MECHANISM OF STEEL FIBRE REINFORCED CONCRETE

    Institute of Scientific and Technical Information of China (English)

    杨佑发; 许绍乾; 钟正华

    2001-01-01

    The stress transfer mechanism of steel fibre reinforced concrete is studied. The solutions for the stress and displacement were regarded as the superposition of "the elementary solutions" and "the improved solutions". The elementary solutions were found by using two-dimensional elastic theory and the improved solutions were found by using the Love displacement function method. The calculated results indicate that the solutions possess good convergence. By comparing the three-dimensional solutions with the shear-lag solutions, evident difference may be found.

  18. Numerical Study Of The Effects Of Preloading, Axial Loading And Concrete Shrinkage On Reinforced Concrete Elements Strengthened By Concrete Layers And Jackets

    Science.gov (United States)

    Lampropoulos, A. P.; Dritsos, S. E.

    2008-07-01

    In this study, the technique of seismic strengthening existing reinforced concrete columns and beams using additional concrete layers and jackets is examined. The finite element method and the finite element program ATENA is used in this investigation. When a reinforced jacket or layer is being constructed around a column it is already preloaded due to existing service loads. This effect has been examined for different values of the axial load normalized to the strengthened column. The techniques of strengthening with a concrete jacket or a reinforced concrete layer on the compressive side of the column are examined. Another phenomenon that is examined in this study is the shrinkage of the new concrete of an additional layer used to strengthen an existing member. For this investigation, a simply supported beam with an additional reinforced concrete layer on the tensile side is examined. The results demonstrate that the effect of preloading is important when a reinforced concrete layer is being used with shear connectors between the old and the new reinforcement. It was also found that the shrinkage of the new concrete reduces the strength of the strengthened beam and induces an initial sliding between the old and the new concrete.

  19. Experimental study on fire protection methods of reinforced concrete beams strengthened with carbon fiber reinforced polymer

    Institute of Scientific and Technical Information of China (English)

    HU Kexu; HE Guisheng; LU Fan

    2007-01-01

    In this paper,two reinforced concrete (RC) beams strengthened with carbon fiber reinforced polymer (CFRP)and attached with thick-painted fire resistant coating were tested for fire resistance following the standard fire testing procedures.The experimental results show that the specimen pasted with the insulated layer of 50 mm in thickness could resist fire for 2.5 h.It is also demonstrated that the steel wire mesh embedded in the insulated layer can effectively prevent it from cracking and eroding under firing.

  20. EXPERIMENTAL RESEARCH OF EFFICIENCY OF DISPERSE REINFORCEMENT OF STRETCHED ZONE OF FLEXURAL CONCRETE ELEMENTS

    OpenAIRE

    V. S. Izotov, R. Kh. Mukhametrakhimov, L. S. Sаbitov

    2011-01-01

    Problem statement. The method of disperse reinforcement of flexural concrete elements by fiber introduction in concrete stretched zone is described.Results and conclusions. The method provides more efficient use and economy of disperse rein-forcement, materials consumption reduction at the maintenance of specified flexural strength, high impact elasticity, and fracture strength. The comparative assessment of disperse reinforcement efficiency for two types of metal fibers is given at reinforce...

  1. Assessment of concrete damage and strength degradation caused by reinforcement corrosion

    Science.gov (United States)

    Nepal, Jaya; Chen, Hua-Peng

    2015-07-01

    Structural performance deterioration of reinforced concrete structures has been extensively investigated, but very limited studies have been carried out to investigate the effect of reinforcement corrosion on time-dependent reliability with consideration of the influence of mechanical characteristics of the bond interface due to corrosion. This paper deals with how corrosion in reinforcement creates different types of defects in concrete structure and how they are responsible for the structural capacity deterioration of corrosion affected reinforced concrete structures during their service life. Cracking in cover concrete due to reinforcement corrosion is investigated by using rebar-concrete model and realistic concrete properties. The flexural strength deterioration is analytically predicted on the basis of bond strength evolution due to reinforcement corrosion, which is examined by the experimental data available. The time-dependent reliability analysis is undertaken to calculate the life time structural reliability of corrosion damaged concrete structures by stochastic deterioration modelling of reinforced concrete. The results from the numerical example show that the proposed approach is capable of evaluating the damage caused by reinforcement corrosion and also predicting the structural reliability of concrete structures during their lifecycle.

  2. Application of Bond-Slip in the Finite Element Analyses of Reinforced Concrete Shear Walls

    Directory of Open Access Journals (Sweden)

    İlker Kazaz

    2012-03-01

    Full Text Available Transfer of tensile forces from reinforcing steel into the surrounding concrete affects the behavior of reinforced concrete members. This transfer relies on the bond action between the steel and the concrete. Under monotonic loading the part of bond strength due to chemical adhesion is easily exhausted and bearing against the lugs is the primary load-transfer mechanism at loads near the ultimate. These stresses cause internal cracking of concrete at the steel-concrete interface. This paper deals with the finite element modeling of the bond-slip and its application due to internal cracking of the first layer of concrete surrounding the bar and the bending and/ or cracking of the small concrete teeth near the bar lugs. A previously proposed constitutive steel stress-bond slip relation by Mirza and Houde (1979 was used in finite element analysis of reinforced concrete shear wall specimens and the results were presented.

  3. Topology optimization of reinforced concrete beams by a spread-over reinforcement model with fixed grid mesh

    Directory of Open Access Journals (Sweden)

    Benjapon Wethyavivorn

    2011-02-01

    Full Text Available For this investigation, topology optimization was used as a tool to determine the optimal reinforcement for reinforcedconcrete beam. The topology optimization process was based on a unit finite element cell with layers of concrete and steel.The thickness of the reinforced steel layer of this unit cell was then adjusted when the concrete layer could not carry thetensile or compressive stress. At the same time, unit cells which carried very low stress were eliminated. The process wasperformed iteratively to create a topology of reinforced concrete beam which satisfied design conditions.

  4. Nondestructive evaluation of dissipative behavior of reinforced concrete structure

    Energy Technology Data Exchange (ETDEWEB)

    Luong, M.P. [Ecole Polytechnique, LMS, CNRS, 91 - Palaiseau (France)

    2001-07-01

    Current technological developments tend toward increased exploitation of materials strengths and toward tackling extreme loads and environmental actions such as offshore structures subject to wind and wave loading, or buildings in seismic area. Concrete is widely used as a construction material because of its high strength-cost ratio in many applications. Experience of earthquakes and laboratory tests has shown that well designed and detailed reinforced concrete is suitable for earthquake resistant structures. The most severe likely earthquake can be survived if the members are sufficiently ductile to absorb and dissipate seismic energy by inelastic deformation. This requires a designer to assess realistically the acceptable levels of strength and to ensure adequate dissipation. This paper proposes the use of infrared thermography as a nondestructive, noncontact and real-time technique to examine diverse mechanisms of dissipation and to illustrate the onset of damage process, stress concentration and heat dissipation localization in loaded zone. In addition, this technique can be used as a nondestructive method for evaluating the fatigue limit of concrete structure subject to repeated loading.

  5. Temperature effects on bond between concrete and reinforcing steel

    Directory of Open Access Journals (Sweden)

    Lublóy Éva

    2014-01-01

    Full Text Available Bond behaviour between concrete and reinforcing bars was observed under elevated temperatures. Five different concrete compositions were used. Hundred five pull-out specimens (Ø120 mm, 100 mm were prepared. After removing the specimens from the formwork, they were stored in water for seven days then kept at laboratory conditions until testing. The specimens were 28 days old by testing. After heating up the specimens, they were kept for two hours at these maximum temperatures (20 °C, 150 °C, 300 °C, 400 °C, 500 °C, 800 °C. Specimens were then cooled down in laboratory conditions. Finally the specimens were tested at room temperature. In order to check the compressive strength standard cubes were cast, cured, and heat treated, then tested to compressive strength. The results showed reduction in residual compressive strength and considerable changes in steel-concrete bond under high temperatures. Based on test results, a proposal is presented for the modification of MC2010 bond-ship formula in order to consider temperature effect.

  6. Shear Strength of Reinforced Concrete Beams Under Sea Water

    Institute of Scientific and Technical Information of China (English)

    阎西康; 王铁成; 张玉敏

    2004-01-01

    The marine structures such as harbour,pier and inshore concrete terrace are exposed in adverse circumstances in a long period of time . Owing to the attack of external corrosive medium, their safety, durability and reliability decline. Especially the reinforced concrete(RC) structures in the wave splash area are more likely to be subjected to destruction and the loss is vast. Now the safety ,durability and reliability of structure have become increasingly an important subject to be studied. By way of the soaking and drying cycle test on the different mix proportions oblique section of 10 pieces of RC beams suffered artificial sea water(ASW) corrosion under 0,35,70,105,140 times of dry-wet cycles ,the compared results of exerting pressure test of these beams under simply supporting were investigated. The law about the changes of the mechanical performance for RC beams with different mix proportions under different time periods for suffering corrosion of dry-wet cycles is as follows: the resistivity to ASW corrosion of the concrete specimens with various water cement ratio( various initial strength) is different; the characters of oblique section failure for RC beams attacked by sea water are about the same as those for ordinary RC beam; along with the extension of the time for sea water attack, the bearing capacity for oblique section of RC beams varies wave upon wave. The specimens attacked by sea water for about 35 times of corrosion cycle achieve minimum bearing capacity.

  7. Earthquake Response of Reinforced Concrete Building Retrofitted with Geopolymer Concrete and X-shaped Metallic Damper

    Science.gov (United States)

    Madheswaran, C. K.; Prakash vel, J.; Sathishkumar, K.; Rao, G. V. Rama

    2017-06-01

    A three-storey half scale reinforced concrete (RC) building is fixed with X-shaped metallic damper at the ground floor level, is designed and fabricated to study its seismic response characteristics. Experimental studies are carried out using the (4 m × 4 m) tri-axial shake-table facility to evaluate the seismic response of a retrofitted RC building with open ground storey (OGS) structure using yielding type X-shaped metallic dampers (also called as Added Damping and Stiffness-ADAS elements) and repairing the damaged ground storey columns using geopolymer concrete composites. This elasto-plastic device is normally incorporated within the frame structure between adjacent floors through chevron bracing, so that they efficiently enhance the overall energy dissipation ability of the seismically deficient frame structure under earthquake loading. Free vibration tests on RC building without and with yielding type X-shaped metallic damper is carried out. The natural frequencies and mode shapes of RC building without and with yielding type X-shaped metallic damper are determined. The retrofitted reinforced concrete building is subjected to earthquake excitations and the response from the structure is recorded. This work discusses the preparation of test specimen, experimental set-up, instrumentation, method of testing of RC building and the response of the structure. The metallic damper reduces the time period of the structure and displacement demands on the OGS columns of the structure. Nonlinear time history analysis is performed using structural analysis package, SAP2000.

  8. Non-traditional shape GFRP rebars for concrete reinforcement

    Science.gov (United States)

    Claure, Guillermo G.

    The use of glass-fiber-reinforced-polymer (GFRP) composites as internal reinforcement (rebars) for concrete structures has proven to be an alternative to traditional steel reinforcement due to significant advantages such as magnetic transparency and, most importantly, corrosion resistance equating to durability and structural life extension. In recent years, the number of projects specifying GFRP reinforcement has increased dramatically leading the construction industry towards more sustainable practices. Typically, GFRP rebars are similar to their steel counterparts having external deformations or surface enhancements designed to develop bond to concrete, as well as having solid circular cross-sections; but lately, the worldwide composites industry has taken advantage of the pultrusion process developing GFRP rebars with non-traditional cross-sectional shapes destined to optimize their mechanical, physical, and environmental attributes. Recently, circular GFRP rebars with a hollow-core have also become available. They offer advantages such as a larger surface area for improved bond, and the use of the effective cross-sectional area that is engaged to carry load since fibers at the center of a solid cross-section are generally not fully engaged. For a complete understanding of GFRP rebar physical properties, a study on material characterization regarding a quantitative cross-sectional area analysis of different GFRP rebars was undertaken with a sample population of 190 GFRP specimens with rebar denomination ranging from #2 to #6 and with different cross-sectional shapes and surface deformations manufactured by five pultruders from around the world. The water displacement method was applied as a feasible and reliable way to conduct the investigation. In addition to developing a repeatable protocol for measuring cross-sectional area, the objectives of establishing critical statistical information related to the test methodology and recommending improvements to

  9. Moment redistribution in continuous reinforced concrete beams strengthened with carbon-fiber-reinforced polymer laminates

    Science.gov (United States)

    Aiello, M. A.; Valente, L.; Rizzo, A.

    2007-09-01

    The results of tests on continuous steel-fiber-reinforced concrete (RC) beams, with and without an external strengthening, are presented. The internal flexural steel reinforcement was designed so that to allow steel yielding before the collapse of the beams. To prevent the shear failure, steel stirrups were used. The tests also included two nonstrengthened control beams; the other specimens were strengthened with different configurations of externally bonded carbon-fiber-reinforced polymer (CFRP) laminates. In order to prevent the premature failure from delamination of the CFRP strengthening, a wrapping was also applied. The experimental results obtained show that it is possible to achieve a sufficient degree of moment redistribution if the strengthening configuration is chosen properly, confirming the results provided by two simple numerical models.

  10. Flexural retrofitting of reinforced concrete structures using Green Natural Fiber Reinforced Polymer plates

    Science.gov (United States)

    Cervantes, Ignacio

    An experimental study will be carried out to determine the suitability of Green Natural Fiber Reinforced Polymer plates (GNFRP) manufactured with hemp fibers, with the purpose of using them as structural materials for the flexural strengthening of reinforced concrete (RC) beams. Four identical RC beams, 96 inches long, are tested for the investigation, three control beams and one test beam. The first three beams are used as references; one unreinforced, one with one layer of Carbon Fiber Reinforced Polymer (CFRP), one with two layers of CFRP, and one with n layers of the proposed, environmental-friendly, GNFRP plates. The goal is to determine the number of GNFRP layers needed to match the strength reached with one layer of CFRP and once matched, assess if the system is less expensive than CFRP strengthening, if this is the case, this strengthening system could be an alternative to the currently used, expensive CFRP systems.

  11. Mechanical Behavior of Rectangular Steel-Reinforced ECC/Concrete Composite Column under Eccentric Compression

    Institute of Scientific and Technical Information of China (English)

    潘金龙; 鲁冰; 顾大伟; 夏正昊; 夏天阳

    2015-01-01

    In order to improve the seismic performance, deformation ability and ultimate load-carrying capacity of columns with rectangular cross section, engineered cementitious composite (ECC) is introduced to partially substitute concrete in the edge zone of reinforced concrete columns and form reinforced ECC/concrete composite columns. Firstly, based on the assumption of plane remaining plane and the simplified constitutive models, the calculation method of the load-carrying capacity of reinforced ECC/concrete columns is proposed. The stress and strain distribu-tions and crack propagation of the composite columns in different states of eccentric compressive loading are ana-lyzed. Then, nonlinear finite element analysis is conducted to study the mechanical performance of reinforced ECC/concrete composite columns with rectangular cross section. It is found that the simulation results are in good agreement with the theoretical results, indicating that the proposed method for calculating the load-carrying capacity of concrete/ECC composite columns is valid. Finally, based on the proposed method, the effects of ECC thickness, com-pressive strength of concrete and longitudinal reinforcement ratio on the mechanical performance of reinforced ECC/concrete composite columns are analyzed. Calculation results indicate that increasing the thickness of ECC layer or longitudinal reinforcement ratio can effectively increase the ultimate load-carrying capacity of the composite column with both small and large eccentricity, but increasing the strength of concrete can only increase the ultimate load-carrying capacity of the composite column with small eccentricity.

  12. Probabilistic Nonlinear Analysis of Reinforced Concrete Bubbler Tower Structure Failure

    Directory of Open Access Journals (Sweden)

    Králik Juraj

    2014-06-01

    Full Text Available This paper describes the reliability analysis of concrete bubbler tower structure of nuclear power plant with the reactor WWER 440 under high internal overpressure. There is showed summary of calculation models and calculation methods for the probability analysis of the structural integrity considering degradation effects and high internal overpressure. The uncertainties of the resistance and the calculation model were taking in the account in the RSM method.

  13. The Shrinkage Cracking Behavior in Reinforced Reactive Powder Concrete Walls

    Directory of Open Access Journals (Sweden)

    Samir A. Al-Mashhadi

    2017-07-01

    Full Text Available In this study, the reduced scale wall models were used (they are believed to resemble as much as possible the field conditions to study the shrinkage behavior of reactive powder concrete (RPC base restrained walls. Six base restrained RPC walls were casted in different length/height ratios of two ratios of steel fiber by volume in Summer. These walls were restrained by reinforced concrete bases to provide the continuous base restraint to the walls. The mechanical properties of reactive powder concrete investigated were; compressive strength between (75.3 – 140.1 MPa, splitting tensile strength between (5.7 – 13.9 MPa, flexural tensile strength (7.7 – 24.5 MPa, and static modulus of elasticity (32.7 – 47.1GPa. Based on the observations of this work, it was found that the cracks did not develop in the reduced scale of the reactive powder concrete (RPC walls restrained from movement at their bases for different L/H ratios (2, 5, and 10 and for two ratio of steel fiber (1% & 2% during 90 days period of drying conditions. Moreover, the shrinkage values increase toward the edges. Based on the results of this work, the increase in the maximum shrinkage values of walls with 1% steel fiber were (29%, 28%, 28% of the maximum shrinkage values of walls with 2% steel fiber of length/height ratios of (2, 5, and 10 respectively. The experimental observation in beam specimens showed that the free shrinkage, tensile strain capacity and elastic tensile strain capacity (at date of cracking of beams with 1% steel fiber were higher than the beams with 2% steel fiber by about (24%, (45% and (42% respectively

  14. Strength Behaviour Of Biomass Fiber-Reinforced Concrete Slab

    Directory of Open Access Journals (Sweden)

    Chai Teck Jung

    2012-05-01

    Full Text Available This paper investigates the compressive strength and flexural strength of biomass fibre-reinforced concrete slab. The main objective of this study is to examine the effect of biomass aggregate and fibre glass on the concrete slab strength. The biomass aggregate is used to replace the natural aggregates. A total of 36 slab samples (250 mm x 600 mm x 50mm thick and 36 numbers of 150 mm cube samples containing 0%, 30%, 60% and 100% biomass aggregate were prepared.  The E-class fibre and Supracoat SP800 were added to increase the strength and to achieve the required workability. All the samples were cured in water with room temperature of around 27oC and tested at the age of 7, 14 and 28 days respectively. The result showed that cube specimens containing 30% biomass aggregate concrete achieved minimum strength of 15 MPa at 28 days. The flexural strength for slab specimens containing 30% biomass aggregate, Supracoat SP 800 and fibre glass gained higher strength compared with control specimens. The 100% biomass aggregate slab achieved 88% of the control specimen strength. The workability was between 150 mm to 170mm slump. The density of the specimens was reduced 20% for cube and 28% for slab compared with control specimens. It can be concluded that the biomass aggregate has good potential as partial aggregate replacement in slab construction when combined with the use of glass fibre and superplasticizer. However, more research needs to be carried out to self-compacting biomass aggregate concrete for sustainable construction

  15. Connections in Precast Buildings using Ultra High-Strength Fibre Reinforced Concrete

    DEFF Research Database (Denmark)

    Hansen, Lars Pilegaard

    1995-01-01

    Ultra high-strength concrete adds new dimensions to the design of concrete structures. It is a brittle material but introducing fibres into the matrix changes the material into a highly ductile material. Furthermore, the fibre reinforcement increases the anchorage of traditional reinforcement bars...

  16. 78 FR 55755 - Steel Concrete Reinforcing Bar From Mexico and Turkey; Institution of Antidumping and...

    Science.gov (United States)

    2013-09-11

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Steel Concrete Reinforcing Bar From Mexico and Turkey; Institution of Antidumping and... from Mexico and Turkey of steel concrete reinforcing bar, primarily provided for in subheadings 7213.10...

  17. Corrosion and protection in reinforced concrete: pulse cathodic protection: an improved cost-effective alternative

    NARCIS (Netherlands)

    Koleva, D.A.

    2007-01-01

    Corrosion and protection in reinforced concrete. Pulse cathodic protection: an improved cost-effective alternative. The aim of the research project was to study the possibilities for establishing a new or improved electrochemical method for corrosion prevention/protection for reinforced concrete. Th

  18. 78 FR 68090 - Steel Concrete Reinforcing Bar from Mexico and Turkey

    Science.gov (United States)

    2013-11-13

    ... COMMISSION Steel Concrete Reinforcing Bar from Mexico and Turkey Determinations On the basis of the record \\1... injured by reason of imports from Mexico and Turkey of steel concrete reinforcing bar, provided for in... alleged to be sold in the United States at less than fair value (LTFV), and by imports of steel...

  19. Seismic response of reinforced concrete frames at different damage levels

    Science.gov (United States)

    Morales-González, Merangeli; Vidot-Vega, Aidcer L.

    2017-03-01

    Performance-based seismic engineering is focused on the definition of limit states to represent different levels of damage, which can be described by material strains, drifts, displacements or even changes in dissipating properties and stiffness of the structure. This study presents a research plan to evaluate the behavior of reinforced concrete (RC) moment resistant frames at different performance levels established by the ASCE 41-06 seismic rehabilitation code. Sixteen RC plane moment frames with different span-to-depth ratios and three 3D RC frames were analyzed to evaluate their seismic behavior at different damage levels established by the ASCE 41-06. For each span-to-depth ratio, four different beam longitudinal reinforcement steel ratios were used that varied from 0.85 to 2.5% for the 2D frames. Nonlinear time history analyses of the frames were performed using scaled ground motions. The impact of different span-to-depth and reinforcement ratios on the damage levels was evaluated. Material strains, rotations and seismic hysteretic energy changes at different damage levels were studied.

  20. EFFECT OF CORROSION ON BOND BEHAVIOR AND BENDING STRENGTH OF REINFORCED CONCRETE BEAMS

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    There is growing concern for corrosion damage in reinforced concrete structures with several decades' service. Pullout tests and beam tests were carried out to study the effect of reinforcement corrosion on the bond behavior and bending strength of reinforced concrete beams. The bond strength of plain bars and concrete initially increases with increasing corrosion, then declines. The turning point depends on the cracking of the concrete cover. The bond strength of deformed bars and concrete increases with corrosion up to a certain amount, but with progressive increase in corrosion, the bond strength decreases, and the cracking of the concrete cover seems to have no effect on the bond strength. On the basis of test data, the bond strength coefficient recommended here, which, together with the bond strength of uncorroded steel bars and concrete, can be used to easily calculate the bond strength of corroded steel bars and concrete. The bond strength coefficient proposed in this paper can be used to study the bond stress-slip relationship of corroded steel bars and concrete. The bending strength of corroded reinforced concrete beams declines with increasing reinforcement corrosion. Decreased bending strength of corroded RC beam is due to reduction in steel bar cross section, reduction of yield strength of steel bar, and reduction of bond capacity between steel bar and concrete.

  1. Efficiency of fiber reinforced concrete application in structures subjected to dynamic effects

    Directory of Open Access Journals (Sweden)

    Morozov Valeriy Ivanovich

    2014-03-01

    Full Text Available Fiber reinforced concretes possess high strength under dynamic loadings, which include impact loads, thanks to their high structural viscosity. This is the reason for using them in difficult operating conditions, where increasing the performance characteristics and the structure durability is of prime importance, and the issues of the cost become less significant. Applying methods of disperse reinforcement is most challenging in case of subtle high-porous materials on mineral binders, for example foamed concrete. At the same time, the experiments conducted in Russia and abroad show, that also in other cases the concrete strength resistance several times increases as a result of disperse reinforcement. This doesn't depend on average density of the concrete and type of fiber used. In the article the fibre reinforced concrete impact resistance is analysed. Recommendations are given in regard to fibre concrete application in manufacture of monolithic floor units for industrial buildings and precast piles.

  2. Modeling of Normal Perforation of Reinforced Concrete Slabs by a Rigid Projectile

    Institute of Scientific and Technical Information of China (English)

    CHEN Xiaowei; LI Xiaoli

    2006-01-01

    An analytical model on the normal perforation of reinforced concrete slabs is constructed.The effect of reinforcing bars is further hybridized in a general three-stage model consisting of initial cratering,tunnelling and shear plugging.Besides three dimensionless numbers,i.e.,the impact function /,the geometry function of projectile N and the dimensionless thickness of concrete target χ,which are employed to predict the ballistic performance of perforation of concrete slabs,the reinforcement ratio ρs of concrete and the tensile strength fs of reinforcing bars are considered as the other main factors influencing the perforation process.Simpler solutions of ballistic performances of normal perforation of reinforced concrete slabs are formulated.Theoretical predictions agree well with individual published experimental data.

  3. Strengthening reinforced concrete beams using prestressed glass fiber-reinforced polymer-Part Ⅰ: Experimental study

    Institute of Scientific and Technical Information of China (English)

    HUANG Yue-lin; WU Jong-hwei; YEN Tsong; HUNG Chien-hsing; LIN Yiching

    2005-01-01

    This work is aimed at studying the strengthening of reinforced concrete (R. C.) beams using prestressed glass fiber-reinforced polymer (PGFRP). Carbon fiber-reinforced polymer (CFRP) has recently become popular for use as repair or rehabilitation material for deteriorated R. C. structures, but because CFRP material is very stiff, the difference in CFRP sheet and concrete material properties is not favorable for transferring the prestress from CFRP sheets to R. C. members. Glass fiber-reinforced polymer (GFRP) sheets with Modulus of Elasticity quite close to that of concrete was chosen in this study. The load-carrying capacities (ultimate loads) and the deflections of strengthened R. C. beams using GFRP and PGFRP sheets were tested and compared. T- and ⊥-shaped beams were used as the under-strengthened and over-strengthened beams. The GFRP sheets were prestressed to one-half their tensile capacities before being bonded to the T- and l-shaped R. C. beams. The prestressed tension in the PGFRP sheets caused cambers in the R. C. beams without cracks on the tensile faces. The PGFRP sheets also enhanced the load-carrying capacity. The test results indicated that T-shaped beams with GFRP sheets increased in load-carrying capacity by 55% while the same beams with PGFRP sheets could increase load-carrying capacity by 100%. The ⊥-shaped beams with GFRP sheets could increase load-carrying capacity by 97% while the same beams with PGFRP sheets could increase the loading-carrying capacity by 117%. Under the same external loads, beams with GFRP sheets underwent larger deflections than beams with PGFRP sheets. While GFRP sheets strengthen R. C. beams, PGFRP sheets decrease the beams' ductility, especially for the over-strengthened beams (⊥-shaped beams).

  4. 78 FR 41079 - Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and Ukraine

    Science.gov (United States)

    2013-07-09

    ... COMMISSION Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and... Tariff Act of 1930 (19 U.S.C. 1675(c)), that revocation of the antidumping duty orders on steel concrete... views of the Commission are contained in USITC Publication 4409 (July 2013), entitled Steel Concrete...

  5. 78 FR 43858 - Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia, Moldova, Poland, the People's...

    Science.gov (United States)

    2013-07-22

    ...] Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia, Moldova, Poland, the People's Republic... Department of Commerce (``Department'') that revocation of the antidumping duty orders \\1\\ on steel concrete... of the continuation of the antidumping duty orders. \\1\\ See Antidumping Duty Orders: Steel Concrete...

  6. Damage and deterioration mechanism and curing technique of concrete structure in main coal cleaning plants

    Institute of Scientific and Technical Information of China (English)

    LV Heng-lin; ZHAO Cheng-ming; SONG Lei; MA Ying; XU Chun-hua

    2009-01-01

    Concrete structures in main coal cleaning plants have been rebuilt and reinforced in the coal mines of the Shanghai Da-tun Energy Sources Co. Ltd., the first colliery of the Pingdingshan Coal Co. Ltd. and the Sanhejian mine of the Xuzhou Mining Group Co. Ltd. In these projects, the operating environment and reliability of concrete structures in the main plants of the three companies were investigated and the safety of the structures inspected. Qualitative and quantitative analyses were made on the spe-cial natural, technological and mechanical environments around the structures. On the basis of these analyses, we discuss the long-term, combined actions of the harsh natural (corrosive gases, liquids and solids) and mechanical environments on concrete structures and further investigated the damage and deteriorating mechanisms and curing techniques of concrete structures in the main coal cleaning plants. Our study can provide a theoretical basis for ensuring the reliability of concrete structures in main coal cleaning plants.

  7. Polymer concrete for precast repair of continuously reinforced concrete pavement on IH 30, near Mt. Pleasant

    Science.gov (United States)

    Meyer, A. M.; McCullough, B. F.; Fowler, D. W.

    1981-08-01

    Two punchout repairs made in a continuously reinforced concrete pavement (CRCP) using precast portland cement panels are described. The two repairs, one 1.44 sq. ft., the other 36 sq. ft., were completed and opened to traffic in one afternoon. This technique provides a rapid method of repair that produces a repair that is structurally as good or better than the surrounding pavement. With a trained crew, the repair time can be reduced and thus reducing lane closure time. Since lane closure time is a critical consideration in high volume highways, this method is cost effective in those areas.

  8. Multi-Physics and Multi-Scale Deterioration Modelling of Reinforced Concrete

    DEFF Research Database (Denmark)

    Michel, Alexander; Stang, Henrik; Lepech, M.;

    2016-01-01

    , methods and tools for modelling decades-long deterioration and maintenance are much less developed. In this paper, a multi-physics and multi-scale modelling approach for structural deterioration of reinforced concrete components due to reinforcement corrosion is presented. The multi-disciplinary modelling......Deterioration of reinforced concrete infrastructure such as bridges, tunnels, and buildings represents one of the major challenges currently facing developed countries. While engineering tools and methods for structural modelling and design of new reinforced concrete infrastructure are mature...

  9. Study of the shear behaviour of fibre reinforced concrete beams

    Directory of Open Access Journals (Sweden)

    Barragán, B.

    2008-12-01

    Full Text Available This study presents a series of tests for characterizing the structural behaviour of fibre reinforced concrete beams subjected to shear loading. The experimental program involves three types of fibres; two steel fibres and a polypropylene fibre. As a reference, plain concrete and conventionally reinforced concrete specimens have also been tested. The ultimate shear capacity of the beams is calculated and these values compared with those predicted by existing formulations. The study confirms that the toughness and shear crack resistance of the material is greatly enhanced by the fibres. However, the incorporation of 1% of fibres yielded lower shear strength than conventionally reinforced beams with the same amount of steel in the form of transversal stirrups. Existing design methods seem sufficiently robust to estimate the maximum shear load, even when using material properties (toughness, tensile strength extrapolated from code formulae.Este trabajo presenta una serie de ensayos para caracterizar el comportamiento estructural de vigas realizadas con hormigón reforzado con fibras sometidas a cortante. El programa de ensayos incluía tres tipos de fibras, dos de acero y una de polipropileno. Asimismo, se realizó una serie de ensayos con una viga confeccionada con hormigón armado convencional. La resistencia a cortante de las vigas es comparada con los valores que la formulación existente predice. El estudio confirma que la tenacidad y la resistencia a cortante son incrementadas tras la adición de fibras al hormigón. Sin embargo, la incorporación de un 1% en volumen de fibras conduce a valores de resistencia última a cortante inferiores a los obtenidos con vigas de hormigón convencional con la misma cantidad de acero dispuesta en forma de cercos de cortante. Los actuales métodos de cálculo parecen lo suficientemente precisos para evaluar la carga de cortante último, incluso cuando los parámetros mecánicos utilizados en las f

  10. Prediction of the Service Life of a Reinforced Concrete Column under Chloride Environment

    Directory of Open Access Journals (Sweden)

    Mohammad K. Alkam

    2015-01-01

    Full Text Available In the present investigation, service life of a reinforced concrete column exposed to chloride environment has been predicted. This study has been based on numerical simulation of chloride ion diffusion in a concrete column during its anticipated life span. The simulation process has included the concrete cover replacement whenever chloride ion concentration has reached the critical threshold value at the reinforcement surface. Repair scheduling of the concrete column under consideration has been discussed. Effects of the concrete cover thickness and the water cement ratio on the service life of the concrete column at hand have been presented. A new approach for arranging locations of reinforcement steel bars has been introduced. This approach is intended to prolong the service life of the concrete column under consideration against chloride induced corrosion.

  11. Utilisation of fibre reinforced polymer (FRP) composites in the confinement of concrete

    OpenAIRE

    Ciupala, Mihaela Anca; Pilakoutas, K.; Mortazavi, A.A.

    2007-01-01

    This paper presents an experimental investigation carried out on concrete cylinders\\ud confined with fibre reinforced polymers (FRP), subjected to monotonic and cyclic loading.\\ud Carbon fibres (CFRP) were used as confining material for the concrete specimens. The failure\\ud mode, reinforcement ratio based on jacket thickness and type of loading are examined. The study\\ud shows that external confinement of concrete can enhance its strength and ductility as well as result\\ud in large energy ab...

  12. Strength Design of Reinforced Concrete Hydraulic Structures; Report 3, T-Wall Design.

    Science.gov (United States)

    1982-01-01

    Concrete Reinforcing Steel Institute. 1978. CRSI Handbook, 3rd ed. Federation Internationale de la Precontrainte (FIP). 1974. "Recommen- dations for... concrete cover to the stirrups and main steel of a bridge floor beam that has been completely spalled off due to severe steel corrosion. 12. In this...Corrosion damage to a bridge floor beam C6 Tensile crack exposure tests by WES 13. Two series of reinforced concrete beams were made and exposed to

  13. Performance Assessment of Discontinuous Fibers in Fiber Reinforced Concrete: Current State-of-the-Art

    Science.gov (United States)

    2017-07-01

    strength between 190 to 240 MPa and is broadly characterized as a reactive powder concrete (RPC). RPCs have fine aggregates and powders but do not...ER D C/ G SL T R- 17 -1 9 Performance Assessment of Discontinuous Fibers in Fiber-Reinforced Concrete : Current State-of-the-Art G eo te...Discontinuous Fibers in Ultra-High Performance Fiber-Reinforced Concrete : Current State-of-the-Art Charles A. Burchfield Geotechnical and

  14. Punching shear of flat reinforced-concrete s labs under fire conditions

    OpenAIRE

    Smith, Holly Kate Mcleod

    2016-01-01

    This thesis examines punching shear response of reinforced-concrete flat slabs under fire conditions. The shear behaviour of concrete in fire is relatively poorly understood compared to its flexural response. Failures such as the Gretzenbach car park failure in Switzerland (2004) have prompted concerns over the punching shear capacity of flat slabs in fire. The shear behaviour of reinforced-concrete in fire depends on degradation of the individual material properties with te...

  15. Numerical Simulation of Monitoring Corrosion in Reinforced Concrete Based on Ultrasonic Guided Waves

    OpenAIRE

    Zheng, Zhupeng; Lei, Ying; Xue, Xin

    2014-01-01

    Numerical simulation based on finite element method is conducted to predict the location of pitting corrosion in reinforced concrete. Simulation results show that it is feasible to predict corrosion monitoring based on ultrasonic guided wave in reinforced concrete, and wavelet analysis can be used for the extremely weak signal of guided waves due to energy leaking into concrete. The characteristic of time-frequency localization of wavelet transform is adopted in the corrosion monitoring of re...

  16. Topology optimization of reinforced concrete beams by a spread-over reinforcement model with fixed grid mesh

    OpenAIRE

    Benjapon Wethyavivorn; Siradech Surit

    2011-01-01

    For this investigation, topology optimization was used as a tool to determine the optimal reinforcement for reinforcedconcrete beam. The topology optimization process was based on a unit finite element cell with layers of concrete and steel.The thickness of the reinforced steel layer of this unit cell was then adjusted when the concrete layer could not carry thetensile or compressive stress. At the same time, unit cells which carried very low stress were eliminated. The process wasperformed i...

  17. Hybrid Effect Evaluation of Steel Fiber and Carbon Fiber on the Performance of the Fiber Reinforced Concrete

    OpenAIRE

    Weimin Song; Jian Yin

    2016-01-01

    Fiber reinforcement is an important method to enhance the performance of concrete. In this study, the compressive test and impact test were conducted, and then the hybrid effect between steel fiber (SF) and carbon fiber (CF) was evaluated by employing the hybrid effect index. Compressive toughness and impact toughness of steel fiber reinforced concrete (SFRC), carbon fiber reinforced concrete (CFRC) and hybrid fiber reinforced concrete (HFRC) were explored at steel fiber volume fraction 0.5%,...

  18. Evaluating cover depth of steel fiber reinforced concrete using impact-echo testing

    Science.gov (United States)

    Lin, Yu-Feng

    2014-04-01

    The purpose of this research is to estimate of the cover depth of steel fiber reinforced concrete using the impact-echo testing. In order to evaluate the security of the construction, usually need to estimate the cover depth of the reinforced concrete. At present, the examination technique of the cover depth of the reinforced concrete without the steel fiber is mainly applied in the magnetic and electrical methods, its rapid detection and good results. But the research of the reactive powder concrete be gradually progress, with the steel fiber concrete structure will be increased, if should still operate the examination with the magnetic and electrical methods, theoretically the steel fiber will have the interference to its electromagnetism field. Therefore, this research designs four kinds of reinforced concrete plate that include different steel fiber contents, to evaluate test results of estimate of the cover depth of the reinforcing bar. The results showed that: estimate of the cover depth of steel fiber reinforced concrete reinforcing bar using the impact-echo testing, the variety of the steel fiber content does not have much influence, the test measurement error within ± 10%, and the most important source of uncertainty is the velocity of concrete.

  19. Confinement of Reinforced-Concrete Columns with Non-Code Compliant Confining Reinforcement plus Supplemental Pen-Binder

    Directory of Open Access Journals (Sweden)

    Anang Kristianto

    2012-11-01

    Full Text Available One of the important requirements for earthquake resistant building related to confinement is the use of seismic hooks in the hoop or confining reinforcement of reinforced-concrete column elements. However, installation of a confining reinforcement with a 135-degree hook is not easy. Therefore, in practice, many construction workers apply a confining reinforcement with a 90-degreehook (non-code compliant. Based on research and records of recent earthquakes in Indonesia, the use of a non-code compliant confining reinforcement for concrete columns produces structures with poor seismic performance. This paper presents a study that introduces an additional element that is expected to improve the effectiveness of concrete columns confined with a non-code compliant confining reinforcement. The additional element, named a pen-binder, is used to keep the non-code compliant confining reinforcement in place. The effectiveness of this element under pure axial concentric loading was investigatedcomprehensively.The specimens tested in this study were 18 concrete columns,with a cross-section of 170 mm x 170 mm and a height of 480 mm. The main test variables were the material type of the pen-binder, the angle of the hook, and the confining reinforcement configuration.The test results indicate that adding pen-binders can effectively improve the strength and ductility of the column specimens confined with a non-code compliant confining reinforcement

  20. Study of Reinforced Concrete Beam-Column Joint

    Directory of Open Access Journals (Sweden)

    Prakash Panjwania

    2015-06-01

    Full Text Available The beam column joint is the crucial zone in a reinforced concrete moment resisting frame. It is subjected to large forces during severe ground shaking and its behaviour has a significant influence on the response of the structure. The assumption of rigid joint fails to consider the effects of high shear forces developed within the joint. The shear failure is always brittle in nature which is not an acceptable structural performance especially in seismic conditions. This paper presents a review of the postulated theories associated with the behaviour of joints. Understanding the joint behaviour is essential in exercising proper judgments in the design of joints. The paper discusses about the seismic actions on various types of joints and highlights the critical parameters that affect joint performance with special reference to bond and shear transfer

  1. Tapered Polymer Fiber Sensors for Reinforced Concrete Beam Vibration Detection

    Directory of Open Access Journals (Sweden)

    Dong Luo

    2016-12-01

    Full Text Available In this study, tapered polymer fiber sensors (TPFSs have been employed to detect the vibration of a reinforced concrete beam (RC beam. The sensing principle was based on transmission modes theory. The natural frequency of an RC beam was theoretically analyzed. Experiments were carried out with sensors mounted on the surface or embedded in the RC beam. Vibration detection results agreed well with Kistler accelerometers. The experimental results found that both the accelerometer and TPFS detected the natural frequency function of a vibrated RC beam well. The mode shapes of the RC beam were also found by using the TPFSs. The proposed vibration detection method provides a cost-comparable solution for a structural health monitoring (SHM system in civil engineering.

  2. Effect of wind in the design of reinforced concrete buildings

    Directory of Open Access Journals (Sweden)

    L.S. Tapajós

    Full Text Available ABSTRACT This paper presents the results from a parametric study carried in order to quantify how far errors in the design stage related to the consideration of the wind action may put at risk the response and safety of reinforced concrete buildings. Using an architectural model as reference and varying the number of floors of the building, the structural safety was evaluated as a function of the wind action intensity. Results showed that even for low-rise buildings, with 10 floors, ignoring the wind action can significantly jeopardize their behaviour and safety. Yet, for slenderer buildings, up to 30 floors, it can lead to catastrophic results, as the ruin of the structure by progressive collapse.

  3. Behaviour of a Blast Loaded Laced Reinforced Concrete Structure

    Directory of Open Access Journals (Sweden)

    N. Anandavalli

    2012-09-01

    Full Text Available Normal 0 MicrosoftInternetExplorer4 According to existing provisions, large separation distance has to be maintained between two conventional explosive storage structures to prevent sympathetic detonation. In this paper, reduction of the separation distance with the use of earth covered laced reinforced concrete (LRC storage structure is demonstrated, which will result in saving of land cost. Details of blast resistant design of 75T (NEC storage structure based on unit risk principle are presented. Performance of the storage structure is evaluated in an actual blast trial. Strain and deflection profiles are obtained from the trial. Based on these, the storage structure is found to be re-usable after the blast trial.Defence Science Journal, 2012, 62(5, pp.284-289, DOI:http://dx.doi.org/10.14429/dsj.62.820

  4. Tapered Polymer Fiber Sensors for Reinforced Concrete Beam Vibration Detection.

    Science.gov (United States)

    Luo, Dong; Ibrahim, Zainah; Ma, Jianxun; Ismail, Zubaidah; Iseley, David Thomas

    2016-12-16

    In this study, tapered polymer fiber sensors (TPFSs) have been employed to detect the vibration of a reinforced concrete beam (RC beam). The sensing principle was based on transmission modes theory. The natural frequency of an RC beam was theoretically analyzed. Experiments were carried out with sensors mounted on the surface or embedded in the RC beam. Vibration detection results agreed well with Kistler accelerometers. The experimental results found that both the accelerometer and TPFS detected the natural frequency function of a vibrated RC beam well. The mode shapes of the RC beam were also found by using the TPFSs. The proposed vibration detection method provides a cost-comparable solution for a structural health monitoring (SHM) system in civil engineering.

  5. Analysis of reinforced concrete beams by the equivalent section method

    CERN Document Server

    Schulz, Mauro

    2014-01-01

    This research investigates the analysis of reinforced concrete beams subjected to combined axial load, bending moment and shear force. Cross-sections of general shape are divided, along the height, into plane elements. The biaxial behavior is represented according to the smeared rotating crack approach. Using traditionally accepted hypotheses for beams, the shear flow is determined by applying the Jouravski formula to an "equivalent section", which takes into account the nonlinear material behavior. The "Equivalent Section Method", originally proposed by Diaz (1980) and Diaz and Schulz (1981), is improved and simplified. The formulation is implemented applying the bidimensional constitutive model A, proposed by Vecchio and Collins (1993). The tension-stiffening effect is considered as adopted by Polak and Vecchio (1993). Shear slip at crack surfaces, Poisson's ratio and other secondary effects are not considered. Validation is undertaken by comparison with experimental results obtained by other researchers. T...

  6. Environmental Impact Optimization of Reinforced Concrete Slab Frame Bridges

    DEFF Research Database (Denmark)

    Yavari, Majid Solat; Du, Guangli; Pacoste, Costin

    2017-01-01

    The main objective of this research is to integrate environmental impact optimization in the structural design of reinforced concrete slab frame bridges in order to determine the most environmental-friendly design. The case study bridge used in this work was also investigated in a previous paper...... focusing on the optimization of the investment cost, while the present study focuses on environmental impact optimization and comparing the results of both of these studies. Optimization technique based on the pattern search method was implemented. Moreover, a comprehensive Life Cycle Assessment (LCA......) methodology of ReCiPe and two monetary weighting systems were used to convert environmental impacts into monetary costs. The analysis showed that both monetary weighting systems led to the same results. Furthermore, optimization based on environmental impact generated models with thinner construction elements...

  7. Seismic Analysis of Reinforced Concrete Shaft Support Water Storage Tank

    Directory of Open Access Journals (Sweden)

    Bharti Tekwani

    2016-05-01

    Full Text Available This paper compares the results of Seismic Analysis of Reinforced Concrete Shaft Support Water Storage Tank carried out in accordance with IS: 1893- 1984 and IS: 1893-2002 (Part-2 draft code. The analysis is carried out for shaft supported water tank of 500,750 and 1000 Cu.m capacity, located in four seismic zones (Zone-II, Zone -III, Zone-IV, Zone-V and on three different soil types (Hard rock, Medium soil, Soft soil. Further, 1000 kl tank for conditions - tank full, tank empty are also considered in this study. The analysis was performed using MAT LAB. The parameters of comparison include base shears, base moments and time history analysis. The above models are analyzed for different time history data such as El Centro, Kobe, Ji-Ji, Erzincan. The comparison is made between the structural responses of one mass and two mass models of above capacity.

  8. Strengthening reinforced concrete beams using prestressed glass fiber-reinforced polymer-Part Ⅱ: Analytical study

    Institute of Scientific and Technical Information of China (English)

    HUANG Yue-lin; HUNG Chien-hsing; YEN Tsong; WU Jong-hwei; LIN Yiching

    2005-01-01

    Strengthening reinforced concrete (R. C.) beams using prestressed glass fiber-reinforced polymer (PGFRP) was studied experimentally as described in Part Ⅰ of this paper (Huang et al., 2005). In that paper, R. C. beams, R. C. beams with GFRP(glass fiber-reinforced polymer) sheets, and R. C. beams with PGFRP sheets were tested in both under-strengthened and over-strengthened cases. The test results showed that the load-carrying capacities (ultimate loads) of the beams with GFRP sheets were greater than those of the beams without polymer sheets. The load-carrying capacities of beams with PGFRP sheets were greater than those of beams with GFRP sheets. The objective of this work is to develop an analytical method to compute all of these load-carrying capacities. This analytical method is independent of the experiments and based only on the traditional R. C.and P. C. (prestressed concrete) theory. The analytical results accorded with the test results. It is suggested that this analytical method be used for analyzing and designing R. C. beams strengthened using GFRP or PGFRP sheets.

  9. 75 FR 47260 - Certain Steel Concrete Reinforcing Bars from Turkey: Notice of Amended Final Results Pursuant to...

    Science.gov (United States)

    2010-08-05

    ... International Trade Administration (A-489-807) Certain Steel Concrete Reinforcing Bars from Turkey: Notice of...) in the 2005-2006 administrative review of certain steel concrete reinforcing bars (rebar) from Turkey..., through March 31, 2006. See Certain Steel Concrete Reinforcing Bars From Turkey; Final Results of...

  10. 75 FR 22552 - Certain Steel Concrete Reinforcing Bars from Turkey; Notice of Amended Final Results Pursuant to...

    Science.gov (United States)

    2010-04-29

    ... International Trade Administration Certain Steel Concrete Reinforcing Bars from Turkey; Notice of Amended Final... Department) in the 2003-2004 administrative review of certain steel concrete of reinforcing bars (rebar) from...) of April 1, 2003, through March 31, 2004. See Certain Steel Concrete Reinforcing Bars From Turkey...

  11. 75 FR 7562 - Certain Steel Concrete Reinforcing Bars From Turkey: Notice of Court Decision Not in Harmony With...

    Science.gov (United States)

    2010-02-22

    ... International Trade Administration Certain Steel Concrete Reinforcing Bars From Turkey: Notice of Court Decision... certain steel concrete reinforcing bars (rebar) from Turkey covering the period of review (POR) of April 1, 2003, through March 31, 2004. See Certain Steel Concrete Reinforcing Bars From Turkey; Final...

  12. Performance based analysis of hidden beams in reinforced concrete structures

    Directory of Open Access Journals (Sweden)

    Helou Samir H.

    2014-01-01

    Full Text Available Local and perhaps regional vernacular reinforced concrete building construction leans heavily against designing slabs with imbedded hidden beams for flooring systems in most structures including major edifices. The practice is distinctive in both framed and in shear wall structures. Hidden beams are favoured structural elements due to their many inherent features that characterize them; they save on floor height clearance; they also save on formwork, labour and material cost. Moreover, hidden beams form an acceptable aesthetic appearance that does not hinder efficient interior space partitioning. Such beams have the added advantage of clearing the way for horizontal electromechanical ductwork. However, seismic considerations, in all likelihood, are seldom seriously addressed. The mentioned structural system of shallow beams is adopted in ribbed slabs, waffle slabs and at times with solid slabs. Ribbed slabs and waffle slabs are more prone to hidden beam inclusion due to the added effective height of the concrete section. Due to the presence of a relatively high reinforcement ratio at the joints the sections at such location tend to become less ductile with unreliable contribution to spandrel force resistance. In the following study the structural influence of hidden beams within slabs is investigated. With the primary focus on a performance based analysis of such elements within a structure. This is investigated with due attention to shear wall contribution to the overall behaviour of such structures. Numerical results point in the direction that the function of hidden beams is not as adequate as desired. Therefore it is strongly believed that they are generally superfluous and maybe eliminated altogether. Conversely, shallow beams seem to render the overall seismic capacity of the structure unreliable. Since such an argument is rarely manifested within the linear analysis domain; a pushover analysis exercise is thus mandatory for behaviour

  13. Seismic analysis of a reinforced concrete containment vessel model

    Energy Technology Data Exchange (ETDEWEB)

    RANDY,JAMES J.; CHERRY,JEFFERY L.; RASHID,YUSEF R.; CHOKSHI,NILESH

    2000-02-03

    Pre-and post-test analytical predictions of the dynamic behavior of a 1:10 scale model Reinforced Concrete Containment Vessel are presented. This model, designed and constructed by the Nuclear Power Engineering Corp., was subjected to seismic simulation tests using the high-performance shaking table at the Tadotsu Engineering Laboratory in Japan. A group of tests representing design-level and beyond-design-level ground motions were first conducted to verify design safety margins. These were followed by a series of tests in which progressively larger base motions were applied until structural failure was induced. The analysis was performed by ANATECH Corp. and Sandia National Laboratories for the US Nuclear Regulatory Commission, employing state-of-the-art finite-element software specifically developed for concrete structures. Three-dimensional time-history analyses were performed, first as pre-test blind predictions to evaluate the general capabilities of the analytical methods, and second as post-test validation of the methods and interpretation of the test result. The input data consisted of acceleration time histories for the horizontal, vertical and rotational (rocking) components, as measured by accelerometers mounted on the structure's basemat. The response data consisted of acceleration and displacement records for various points on the structure, as well as time-history records of strain gages mounted on the reinforcement. This paper reports on work in progress and presents pre-test predictions and post-test comparisons to measured data for tests simulating maximum design basis and extreme design basis earthquakes. The pre-test analyses predict the failure earthquake of the test structure to have an energy level in the range of four to five times the energy level of the safe shutdown earthquake. The post-test calculations completed so far show good agreement with measured data.

  14. Uncertainty modelling of critical column buckling for reinforced concrete buildings

    Indian Academy of Sciences (India)

    Kasim A Korkmaz; Fuat Demir; Hamide Tekeli

    2011-04-01

    Buckling is a critical issue for structural stability in structural design. In most of the buckling analyses, applied loads, structural and material properties are considered certain. However, in reality, these parameters are uncertain. Therefore, a prognostic solution is necessary and uncertainties have to be considered. Fuzzy logic algorithms can be a solution to generate more dependable results. This study investigates the material uncertainties on column design and proposes an uncertainty model for critical column buckling reinforced concrete buildings. Fuzzy logic algorithm was employed in the study. Lower and upper bounds of elastic modulus representing material properties were defined to take uncertainties into account. The results show that uncertainties play an important role in stability analyses and should be considered in the design. The proposed approach is applicable to both future numerical and experimental researches. According to the study results, it is seen that, calculated buckling load values are stayed in lower and upper bounds while the load values are different for same concrete strength values by using different code formula.

  15. Humectant use in the cathodic protection of reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, Gordon R.; Covino, Bernard S., Jr.; Russell, James H.; Bullard, Sophie J.; Cramer, Stephen D.; Collins, W.K.; Bennett, J.E. (JE Bennett Consulting); Laylor, H.M. (ODOT)

    2000-11-01

    Use of humectants to improve the thermal-sprayed zinc anode performance during the cathodic protection (CP) of reinforced concrete was examined. A humectant is a hygroscopic material. It is applied onto the surface of the zinc anode to keep the concrete-anode interface moist and a good conductor. The thermodynamics of humectants are discussed. Laboratory results are presented on the effects of using lithium bromide (LiBr) and lithium nitrate (LiNO{sub 3}) as humectants in galvanic cathodic protection (GCP) and impressed current cathodic protection (ICCP) systems, in high and low relative humidities, and on new and previously electrochemically aged CP systems. LiNO{sub 3} and LiBr promoted more effective CP performance. Both improved the performance of aged slabs, suggesting that application of humectants onto existing CP systems would be of benefit. Microscopy showed that humectant-treated slabs develop the same cement-reaction zone, zinc anode structures as untreated slabs. Microscopy of LiBr-treated slabs revealed that the highest concentration of bromide was in the reaction zone. In GCP tests, LiBr was more effective than LiNO{sub 3}. In accelerated ICCP tests, LiNO{sub 3} was more effective than LiBr. It was surmised that bromide could be oxidized in the high-voltage accelerated ICCP tests. At the lower impressed currents of most installed ICCP systems, LiBr may perform as well as or better than LiNO{sub 3}.

  16. Humectant use in the cathodic protection of reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, G.R.; Covino, B.S. Jr.; Russell, J.H.; Bullard, S.J.; Cramer, S.D.; Collins, W.K.; Bennett, J.E. (not a DOE author); H.M. Laylor (not a DOE author)

    2000-03-01

    The use of humectants to improve the thermal-sprayed zinc anode performance during the cathodic protection (CP) of reinforced concrete is examined. A humectant is a hygroscopic material. It is applied onto the surface of the zinc anode to keep the concrete-anode interface moist and a good conductor. The thermodynamics of humectants are discussed. Laboratory results are presented on the effects of using LiBr and LiNO{sub 3} as humectants in galvanic (GCP) and impressed current (ICCP) systems, in high and low relative humidities, and on new and previously electrochemically aged CP systems. LiNO{sub 3} and LiBr promoted more effective CP performance. Both improved the performance of aged slabs, suggesting that application of humectants onto existing CP systems would be of benefit. Microscopy showed that humectant-treated slabs develop the same cement-reaction zone-zinc anode structures as untreated slabs. Microscopy of LiBr-treated slabs revealed that the highest concentration of bromide was in the reaction zone. In GCP tests, LiBr was more effective than LiNO{sub 3}. In accelerated ICCP tests, LiNO{sub 3} was more effective than LiBr. It was surmised that bromide could be oxidized in the high-voltage accelerated ICCP tests. At the lower impressed currents of most installed ICCP systems, LiBr may perform as well as or better than LiNO{sub 3}.

  17. Crack Identification in Reinforced Concrete Beams Using Ansys Software

    Directory of Open Access Journals (Sweden)

    T. Subramani

    2014-06-01

    Full Text Available Analytical determination of displacements and stresses in reinforced concrete material was difficult task and engineers had to rely on empirical formulas because concrete consists of heterogeneous material and creep and shrinkage influenced deformations in it. Due to these complexities engineers in past had been facing difficulties in coping such problems, but with the advancement of digital computerization and modern numerical methods for analysis such as finite element method, these problems can be addressed in a very efficient way. There were two ways to carry out modelling in ANSYS software, one was smeared approach and the other one was discrete. In the past, Smeared approach was used to identify the cracks in RC beam using ANSYS but in this work it was extended using discrete approach of modelling and shear cracks were identified in RC beam and load deflection curve was simulated which showed good agreement with the experimental results. Beams, made of brittle materials like concrete or cement, show increasing crack development during their service life due to mechanical and environmental loadings. This local damage can be translated into a reduction of the local bending stiffness. Stiffness modifications, while assuming constant mass distribution, can be observed by monitoring the vibration behaviour of the beam. In this paper the modal parameters of an undamaged beam are monitored and compared with the vibration behaviour of the beam subjected to controlled damaging. Selected stiffness parameters in the finite element model are adjusted in such a way that the computed modal quantities match the measured quantities. FEMtools has been used to establish a damage distribution in beams associated with increasing stress patterns. State of the art scanning laser modal equipment has been used for this purpose. It has been found that modal updating is indeed a possible tool to reconstruct the damage patterns.

  18. Shear-deforming textile reinforced concrete for the construction of double-curved structures

    NARCIS (Netherlands)

    Woodington, W.; Bergsma, O.K.; Schipper, H.R.

    2015-01-01

    A composite textile reinforced concrete (TRC) material is developed to overcome the difficulties of constructing double-curved freeform structures. This is possible by shear-deformation of the woven reinforcement. It affects the direction of reinforcement and thickness, resulting in variable orthotr

  19. Behavior and Performance of GFRP Reinforced Concrete Columns with Various Types of Stirrups

    Directory of Open Access Journals (Sweden)

    Woraphot Prachasaree

    2015-01-01

    Full Text Available Fiber reinforced polymer (FRP composites are gaining acceptance in concrete structural applications due to their high ratio of strength/stiffness to self-weight and corrosion resistance. This study focused on the structural behavior and the performance of concrete columns internally reinforced with glass fiber reinforced plastic (GFRP rebars. Twelve series of concrete columns with varied longitudinal reinforcement, cross section, concrete cover, and type of lateral reinforcement were tested under compression loading. The results show that the amount of GFRP longitudinal and lateral reinforcement slightly affects the column strength. The lateral reinforcement affects the confining pressure and inelastic deformation, and its contribution to the confined compressive strength increases with the GFRP reinforcement ratio. In addition, the confining pressure increases both concrete strength and deformability in the inelastic range. The confinement effectiveness coefficient varied from 3.0 to 7.0 with longitudinal reinforcement. The average deformability factors were 4.2 and 2.8 with spirals and ties, respectively. Lateral reinforcement had a more pronounced effect on deformability than on column strength.

  20. Analytical Study on the Beyond Design Seismic Capacity of Reinforced Concrete Shear Walls

    Energy Technology Data Exchange (ETDEWEB)

    Nugroho, Tino Sawaldi Adi [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Chi, Ho-Seok [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    The OECD-NEA has organized an international benchmarking program to better understand this critical issue. The benchmark program provides test specimen geometry, test setup, material properties, loading conditions, recorded measures, and observations of the test specimens. The main objective of this research is to assess the beyond design seismic capacity of the reinforced concrete shear walls tested at the European Laboratory for Structural Assessment between 1997 and 1998 through participation in the OECD-NEA benchmark program. In this study, assessing the beyond design seismic capacity of reinforced concrete shear walls is performed analytically by comparing numerical results with experimental results. The seismic shear capacity of the reinforced concrete shear wall was predicted reasonably well using ABAQUS program. However, the proper calibration of the concrete material model was necessary for better prediction of the behavior of the reinforced concrete shear walls since the response was influenced significantly by the material constitutive model.

  1. Assessment of Methods for Development of Confinement Model of Low Strength Reinforced Concrete Columns: A Review

    Directory of Open Access Journals (Sweden)

    Asif Ali

    2016-10-01

    Full Text Available Reinforced Concrete is composed of concrete and steel, where compressive strength of concrete and tensile strength of steel are utilized to achieve the required member strength. The high tensile property of steel is thus used to confine and increase compressive strength and ductility of RC columns. Confined concrete is defined as concrete that is restrained laterally by any internal or external means i.e. reinforcement consisting of steel stirrups or spirals, Fiber Reinforced Polymer (FRP, Circular Concrete Filled Steel Tube, RC shell jacketing etc. An appropriate amount of confinement increases the strength, ductility and energy dissipation capacity of RC members. This paper focuses on finding out strength and ductility enhancement of low strength RC columns by reinforcement using existing confinement models. Confinement models are stress-strain curves developed for concrete compression member under uniaxial or dynamic loading, confined with transverse reinforcement. Different models along with their experimental validations are discussed in this paper to get state of the art knowledge of confinement studies possible for low strength concrete. The models recommended from this study are used to evaluate existing structures made with low strength concrete

  2. Mechanical interaction between concrete and structural reinforcement in the tension stiffening process

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor; Jönsson, Jeppe

    2011-01-01

    investigated using an image-based deformation measurement and analysis system. This allowed for detailed view of surface deformations and the implications on the resulting response of the member in tension. In this study, conventional concrete and a ductile, strain hardening cement composite, known......The interaction between structural reinforcement and the surrounding concrete matrix in tension is a governing mechanism in the structural response of reinforced concrete members. The tension stiffening process, defined as the concrete ´s contribution to tensile response of the composite, has been...... as Engineered Cementitious Composite (ECC), have been combined with steel and glass fiber reinforced polymer (GFRP) reinforcement to contrast the effects of brittle and ductile cement matrices as well as elastic/plastic and elastic reinforcement on the tension stiffening process. Particular focus...

  3. Analysis on plastic properties of reactive powder concrete continuous beams reinforced with GFRP bars

    Institute of Scientific and Technical Information of China (English)

    LU Shan-shan; ZHENG Wen-zhong

    2010-01-01

    To study the plastic properties of reactive powder concrete continuous beams reinforced with GFRP bars,the calculation programs for moment redistribution coefficients are prepared by using nonlinear analysis methods such as moment-curvature,conjugate beam method and so on.By comparing the test results of existed FRP bars reinforced concrete continuous beams with simulation results,the accuracy of the calculation program is verified.Then 18 simulated GFRP bars reinforced reactive powder concrete continuous beams are selected whose change parameters are reinforcement ratio of mid-span and middle support.Through the nonlinear analysis of simulated beams,moment redistribution coefficients under mid-span concentrated loads,one-third point loads and uniformly distributed loads are obtained respectively.Thus the formula of moment redistribution coefficients is obtained by fitting moment redistribution coefficients and factors.The results show that the reactive powder concrete continuous beams reinforced with GFRP bars have good plastic properties.

  4. Strength Modeling of Reinforced Concrete Beam with Externally Bonded FRP Reinforcement

    Directory of Open Access Journals (Sweden)

    N. Pannirselvam

    2008-01-01

    Full Text Available This research study presents the evaluation of the structural behaviour of reinforced concrete beams with externally bonded Fibre Reinforced Polymer (FRP reinforcements. Three different steel ratios with two different Glass Fibre Reinforced Polymer (GFRP types and two different thicknesses in each type of GFRP were used. Totally fifteen rectangular beams of 3 m length were cast. Three rectangular beams were used as reference beam (Control Beams and the remaining were fixed with GFRP laminates on the soffit of the rectangular beam. The variables considered for the study includes longitudinal steel ratio, type of GFRP laminates, thickness of GFRP laminates and composite ratios. Flexural test, using simple beam with third-point loading was adopted to study the performance of FRP plated beams interms flexural strength, deflection, ductility and was compared with the unplated beams. The test results show that the beams strengthened with GFRP laminates exhibit better performance. The flexural strength and ductility increase with increase in thickness of GFRP plate. The increase in first crack loads was up to 88.89% for 3 mm thick WRGFRP plates and 100.00% for 5 mm WRGFRP plated beams and increase in ductility interms of energy and deflection was found to be 56.01 and 64.69% respectively with 5 mm thick GFRP plated beam. Strength models were developed for predicting the flexural strength (ultimate load, service load and ductility of FRP beams. The strength model developed give prediction matching the measurements.

  5. Application of Cu-Al-Mn superelastic alloy bars as reinforcement elements in concrete beams

    Science.gov (United States)

    Shrestha, Kshitij C.; Araki, Yoshikazu; Nagae, Takuya; Yano, Hayato; Koetaka, Yuji; Omori, Toshihiro; Sutou, Yuji; Kainuma, Ryosuke; Ishida, Kiyohito

    2012-04-01

    Experimental works are done to assess the seismic behavior of concrete beams reinforced with superelastic alloy (SEA) bars. Applicability of newly developed Cu-Al-Mn SEA bars, characterized by large recovery strain, low material cost, and high machinability, have been proposed as partial replacements for conventional steel bars in order to reduce residual deformations in structures during and after intense earthquakes. Four-point reverse-cyclic bending tests were done on 1/3 scale concrete beams comprising three different types of specimens - conventional steel reinforced concrete (ST-RC), SEA reinforced concrete (SEA-RC), and SEA reinforced concrete with pre-tensioning (SEA-PC). The results showed that SEA reinforced concrete beams demonstrated significant enhancement in crack recovery capacity in comparison to steel reinforced beam. Average recovery of cracks for each of the specimens was 21% for ST-RC, 84% for SEA-RC, and 86% for SEA-PC. In addition, SEA-RC and SEA-PC beams demonstrated strong capability of recentering with comparable normalized strength and ductility relative to conventional ST-RC beam specimen. ST-RC beam, on the other hand, showed large residual cracks due to progressive reduction in its re-centering capability with each cycle. Both the SEA-RC and SEA-PC specimens demonstrated superiority of Cu-Al-Mn SEA bars to conventional steel reinforcing bars as reinforcement elements.

  6. Preparation and characterization of glass fibers - polymers (epoxy) bars (GFRP) reinforced concrete for structural applications

    Science.gov (United States)

    Alkjk, Saeed; Jabra, Rafee; Alkhater, Salem

    2016-06-01

    The paper presents some of the results from a large experimental program undertaken at the Department of Civil Engineering of Damascus University. The project aims to study the ability to reinforce and strengthen the concrete by bars from Epoxy polymer reinforced with glass fibers (GFRP) and compared with reinforce concrete by steel bars in terms of mechanical properties. Five diameters of GFRP bars, and steel bars (4mm, 6mm, 8mm, 10mm, 12mm) tested on tensile strength tests. The test shown that GFRP bars need tensile strength more than steel bars. The concrete beams measuring (15cm wide × 15cm deep × and 70cm long) reinforced by GFRP with 0.5 vol.% ratio, then the concrete beams reinforced by steel with 0.89 vol.% ratio. The concrete beams tested on deflection test. The test shown that beams which reinforced by GFRP has higher deflection resistance, than beams which reinforced by steel. Which give more advantage to reinforced concrete by GFRP.

  7. Preparation and characterization of glass fibers – polymers (epoxy bars (GFRP reinforced concrete for structural applications

    Directory of Open Access Journals (Sweden)

    Alkjk Saeed

    2016-06-01

    Full Text Available The paper presents some of the results from a large experimental program undertaken at the Department of Civil Engineering of Damascus University. The project aims to study the ability to reinforce and strengthen the concrete by bars from Epoxy polymer reinforced with glass fibers (GFRP and compared with reinforce concrete by steel bars in terms of mechanical properties. Five diameters of GFRP bars, and steel bars (4mm, 6mm, 8mm, 10mm, 12mm tested on tensile strength tests. The test shown that GFRP bars need tensile strength more than steel bars. The concrete beams measuring (15cm wide × 15cm deep × and 70cm long reinforced by GFRP with 0.5 vol.% ratio, then the concrete beams reinforced by steel with 0.89 vol.% ratio. The concrete beams tested on deflection test. The test shown that beams which reinforced by GFRP has higher deflection resistance, than beams which reinforced by steel. Which give more advantage to reinforced concrete by GFRP.

  8. Reinforcement layout design for concrete structures based on continuum damage and truss topology optimization

    DEFF Research Database (Denmark)

    Amir, Oded; Sigmund, Ole

    2013-01-01

    This article presents a new procedure for the layout design of reinforcement in concrete structures. Concrete is represented by a gradient-enhanced continuum damage model with strain-softening and reinforcement is modeled as elastic bars that are embedded into the concrete domain. Adjoint...... sensitivity analysis is derived in complete consistency with respect to path-dependency and the nonlocal model. Classical truss topology optimization based on the ground structure approach is applied to determine the optimal topology and cross-sections of the reinforcement bars. This approach facilitates...

  9. Analysis of time-dependent reliability of degenerated reinforced concrete structure

    Directory of Open Access Journals (Sweden)

    Zhang Hongping

    2016-07-01

    Full Text Available Durability deterioration of structure is a highly random process. The maintenance of degenerated structure involves the calculation of the reliability of time-dependent structure. This study introduced reinforced concrete structure resistance decrease model and related statistical parameters of uncertainty, analyzed resistance decrease rules of corroded bending element of reinforced concrete structure, and finally calculated timedependent reliability of the corroded bending element of reinforced concrete structure, aiming to provide a specific theoretical basis for the application of time-dependent reliability theory.

  10. Analytical Model for Fictitious Crack Propagation in Reinforced Concrete Beams without Debonding

    DEFF Research Database (Denmark)

    Ulfkjær, J. P.; Brincker, Rune

    1994-01-01

    , the crack growth is further simplified by introducing a continuous layer of springs at the midsection mainly representing a simplified material response around the fracture zone. In the reinforcement the strain condition is assumed to be equal to the strain condition in the concrete. the important question......The non-linear fracture mechanical problem of combined crack growth and reinforcement action is modelled by adopting a simplified fictitious crack model for concrete and a linear elastic-plastic action for the reinforcement. The softening relation of the concrete is assumed to be linear, however...

  11. Studies on the corrosion resistance of reinforced steel in concrete with ground granulated blast-furnace slag--An overview.

    Science.gov (United States)

    Song, Ha-Won; Saraswathy, Velu

    2006-11-16

    The partial replacement of clinker, the main constituent of ordinary Portland cement by pozzolanic or latent hydraulic industrial by-products such as ground granulated blast furnace slag (GGBFS), effectively lowers the cost of cement by saving energy in the production process. It also reduces CO2 emissions from the cement plant and offers a low priced solution to the environmental problem of depositing industrial wastes. The utilization of GGBFS as partial replacement of Portland cement takes advantage of economic, technical and environmental benefits of this material. Recently offshore, coastal and marine concrete structures were constructed using GGBFS concrete because high volume of GGBFS can contribute to the reduction of chloride ingress. In this paper, the influence of using GGBFS in reinforced concrete structures from the durability aspects such as chloride ingress and corrosion resistance, long term durability, microstructure and porosity of GGBFS concrete has been reviewed and discussed.

  12. Soft impact testing of a wall-floor-wall reinforced concrete structure

    Energy Technology Data Exchange (ETDEWEB)

    Vepsä, Ari, E-mail: ari.vepsa@vtt.fi; Calonius, Kim; Saarenheimo, Arja; Aatola, Seppo; Halonen, Matti

    2017-01-15

    Highlights: • A wall-floor-wall reinforced concrete structure was built. • The structure was subjected to three almost identical soft impact tests. • Response was measured with accelerometers, displacement sensors and strain gauges. • Modal tests was also carried out with the same structure in different conditions. • The results are meant to be used for validation of computational methods and models. - Abstract: Assessing the safety of the reactor building of a nuclear power plant against the crash of an airplane calls for valid computational tools such as finite element models and material constitutive models. Validation of such tools and models in turn calls for reliable and relevant experimental data. The problem is that such data is scarcely available. One of the aspects of such a crash is vibrations that are generated by the impact. These vibrations tend to propagate from the impact point to the internal parts of the building. If strong enough, these vibrations may cause malfunction of the safety-critical equipment inside the building. To enable validation of computational models for this type of behaviour, we have conducted a series of three tests with a wall-floor-wall reinforced concrete structure under soft impact loading. The response of the structure was measured with accelerometers, displacement sensors and strain gauges. In addition to impact tests, the structure was subjected to modal tests under different conditions. The tests yielded a wealth of useful data for validation of computational models and better understanding about shock induced vibration physics especially in reinforced concrete structures.

  13. Experimental and finite element analysis of bond-slip in reinforced concrete

    Directory of Open Access Journals (Sweden)

    A. R. V. WOLENSKI

    Full Text Available Abstract The modeling of reinforced concrete structures has taken advantage of the increasing progress on Computational Mechanics, in such way that complex phenomena, such as cracking and crushing, creep, reinforcement yielding, steel-concrete bond loss, can be modeled in a reasonable realistic way, using the proper set of numerical and computational resources. Among several options, the ones based on the Finite Element Method (FEM allow complex analysis simulations of reinforced concrete structures, including the interaction of different nonlinear effects. This paper deals with the nonlinear finite element analysis of the bond-slip between reinforcing steel and concrete, taking into account an experimental study previously performed. The FEM analysis presented uses a combination of resources where the material behavior of concrete is described by the Microplane Constitutive Model, and an embedded reinforcement model is used to represent steel inside the concrete and take into account the effect of bond-slip. The FEM models were created using the INSANE (INteractive Structural ANalysis Environment computational system, open source software that has a set of FEM tools for nonlinear analysis of reinforced concrete structures. The correlations between numerical-experimentals results and several parameters validate the proposed combination of resources and identifies the significance of various effects on the response.

  14. Structural Engineering Properties of Fibre Reinforced Concrete Based On Recycled Glass Fibre Polymer (GFRP)

    OpenAIRE

    Adetiloye A; Ephraim M. E

    2015-01-01

    Glass fibre reinforced plastics (GFRP) based on resin recovered from recycling plastic waste has been shown to possess mechanical properties satisfying normative requirements. This paper investigates the flexural behavior of concrete beams reinforced with GFRP produced from resin recovered from recycled plastic wastes. A total of twelve of beams of sizes 150 ×150 ×900mm and 100 × 100 × 500mm reinforced with GFRP made from recycled glass fibre reinforced polymer was tested. The fle...

  15. Fracture Behavior and Properties of Functionally Graded Fiber-Reinforced Concrete

    Science.gov (United States)

    Roesler, Jeffery; Bordelon, Amanda; Gaedicke, Cristian; Park, Kyoungsoo; Paulino, Glaucio

    2008-02-01

    In concrete pavements, a single concrete mixture design is selected to resist mechanical loading without attempting to adversely affect the concrete pavement shrinkage, ride quality, or noise attenuation. An alternative approach is to design distinct layers within the concrete pavement surface which have specific functions thus achieving higher performance at a lower cost. The objective of this research was to address the structural benefits of functionally graded concrete materials (FGCM) for rigid pavements by testing and modeling the fracture behavior of different combinations of layered plain and synthetic fiber-reinforced concrete materials. Fracture parameters and the post-peak softening behavior were obtained for each FGCM beam configuration by the three point bending beam test. The peak loads and initial fracture energy between the plain, fiber-reinforced, and FGCM signified similar crack initiation. The total fracture energy indicated improvements in fracture behavior of FGCM relative to full-depth plain concrete. The fracture behavior of FGCM depended on the position of the fiber-reinforced layer relative to the starter notch. The fracture parameters of both fiber-reinforced and plain concrete were embedded into a finite element-based cohesive zone model. The model successfully captured the experimental behavior of the FGCMs and predicted the fracture behavior of proposed FGCM configurations and structures. This integrated approach (testing and modeling) demonstrates the viability of FGCM for designing layered concrete pavements system.

  16. Foundation Design for a High Bay Warehouse with a Steel Fibre Reinforced Concrete Slab

    DEFF Research Database (Denmark)

    Kasper, T.; Sørensen, Carsten Steen; Nielsen, J. B.

    2008-01-01

    concrete slabs, while a 69 x 77 m and 40 cm thick steel fibre reinforced concrete (SFRC) slab forms the inner part of the foundation. Steel fibre reinforcement has been chosen mainly due to approximately 15 % lower construction costs than a comparable solution with conventional rebar reinforcement......The high bay warehouse at the Carlsberg brewery in Fredericia, Denmark, is 40 m high and is founded with a 83 x 116 m foundation slab on clay till and sand layers. Due to the wind loads on the tall building, the edges of the foundation require 80 cm and 60 cm thick conventionally reinforced...

  17. Finite Element Reliability Analysis of Chloride Ingress into Reinforced Concrete Structures

    DEFF Research Database (Denmark)

    Frier, Christian; Sørensen, John Dalsgaard

    2007-01-01

    For many reinforced concrete structures corrosion of the reinforcement is an important problem since it can result in maintenance and repair actions. Further, a reduction of the load-bearing capacity can occur. In the present paper the Finite Element Reliability Method (FERM) is employed for obta......For many reinforced concrete structures corrosion of the reinforcement is an important problem since it can result in maintenance and repair actions. Further, a reduction of the load-bearing capacity can occur. In the present paper the Finite Element Reliability Method (FERM) is employed...

  18. A Probabilistic Model for Chloride-Ingress and Initation of Corrosion in Reinforced Concrete Structures

    DEFF Research Database (Denmark)

    Engelund, S.; Sørensen, John Dalsgaard

    1998-01-01

    value. In the present paper a statistical model by which the chloride content in a reinforced concrete structure can be predicted, is developed. The model parameters are estimated on the basis of measurements. The distribution of the time to initiation of corrosion can now be estimated by traditional......Corrosion of the reinforcement is a major problem for a large number of reinforced concrete structures because it can lead to a substantial decrease of the load-bearing capacity. One mode of corrosion initiation is that the chloride content around the reinforcement exceeds a critical threshold...

  19. Shear strengthening of pre-damaged reinforced concrete beams with carbon fiber reinforced polymer sheet strips

    Institute of Scientific and Technical Information of China (English)

    Feras ALZOUBI; ZHANG Qi; LI Zheng-liang

    2007-01-01

    This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer (CFRP) sheet. The reasearch included four test rectangular simply supported RC beams in shear capacity. One is the control beam, two RC beams are damaged to a predetermined degree from ultimate shear capacity of the control beam, and the last beam is left without pre-damaged and then strengthened with using externally bonded carbon fiber reinforced polymer to upgrade their shear capacity. We focused on the damage degree to beams during strengthening, therefore, only the beams with side-bonded CFRPs strips and horizontal anchored strips were used. The results show the feasibility of using CFRPs to restore or increase the load-carrying capacity in the shear of damaged RC beams. The failure mode of all the CFRP-strengthened beams is debonding of CFRP vertical strips. Two prediction available models in ACI-440 and fib European code were compared with the experimental results.

  20. Strengthening of Corrosion-Damaged Reinforced Concrete Beams with Glass Fiber Reinforced Polymer Laminates

    Directory of Open Access Journals (Sweden)

    A. L. Rose

    2009-01-01

    Full Text Available Problem statement: This study showed the results of an experimental investigation on the strengthening of corrosion damaged reinforced concrete beams with unidirectional cloth glass fiber reinforced polymer (UDCGFRP laminates. Approach: All the beam specimens 150×250×3000 mm were cast and tested for the present investigation. One beam specimen was neither corroded nor strengthened to serve as a reference. Two beams were corroded to serve as a corroded control. A reinforcement mass loss of approximately 10 and 25% were used to define medium and severe degrees of corrosion. The remaining two beams corroded and strengthened with GFRP. Results: The test parameters included first crack load, first crack deflection, yield load, yield deflection, service load, service deflection, ultimate load and ultimate deflection. Based on the results it was found that GFRP Laminates had beneficial effects even at the corrosion-damaged stage. Conclusion/Recommendations: The UDCGFRP laminated beams showed distinct enhancement in ultimate strength and ductility by 72.37 and 49.49% respectively.

  1. Strength Modeling of High-Strength Concrete with Hybrid Fibre Reinforcement

    Directory of Open Access Journals (Sweden)

    A. Ravichandran

    2009-01-01

    Full Text Available The low tensile strength and limited ductility, the unavoidable deficiency, of concrete can be overcome by the addition of fibres. High strength concrete (HSC of 60 MPa containing hybrid fibres, combination of steel and polyolefin fibres, at different volume fraction of 0.5, 1.0, 1.5 and 2.0% were compared in terms of compressive, splitting tensile strength and flexural properties with HSC containing no fibres. Test results showed that the fibres when used in hybrid form could result in enhanced flexural toughness compared to steel fibre reinforced concrete [HSFRC]. The compressive strength of the fibre-reinforced concrete reached maximum at 1.5% volume fractions and the splitting tensile strength and modulus of rupture improved with increasing volume fraction. Strength models were established to predict the compressive and splitting tensile strength and modulus of rupture of the fibre-reinforced concrete. The models give prediction matching the measurements.

  2. Experimental Study on Common and Steel Fiber Reinforced Concrete Under Dynamic Tensile Stress

    Institute of Scientific and Technical Information of China (English)

    董新龙; 陈江瑛; 高培正; 祁振林; 王永忠; 王永刚; 王礼立

    2004-01-01

    Split Hopkinson technique has been developed to test the strength of common concrete and steel fiber reinforced concrete under dynamic tensile stress. Two types of test methods are considered, the splitting tensile test and a modified spalling test in which a specimen is loaded under uniaxial stress. The result shows that the dynamic strength enhancement of concrete is remarkable by using the reinforcing fiber. But for the common concrete, the base of compressive strength seems to show little effect on the tensile strength under dynamic loading. The experimental results also show that the resistance to tensile fracture of the steel fiber reinforced concrete for C100-mix is higher than those of C40-mix.

  3. Potential Effects of Corrosion Damage on the Performance of Reinforced Concrete Member

    Directory of Open Access Journals (Sweden)

    Mohd Noh Hamidun

    2016-01-01

    Full Text Available Corrosion of steel in reinforced concrete is one of the most serious issues for the owners. The main consequences of this phenomenon include loss of cross section of steel area, induced the expansive pressure which caused cracking of concrete, spalling and delaminating of the concrete cover. Thus, it reduces the bond strength between steel reinforcing bar and concrete, and deteriorates the strength of whole structure. In this study, a non-linear finite element analysis was conducted to investigate the potential effects of corrosion damage. A series of corroded reinforced concrete cylinder is used in the parametric study to assess the influence of different level of corrosion to the structural performance. As a result, a clear picture of corrosive expansion was investigated and the relationship between the expansive pressure and the degree of corrosion was identified to be the important factors of the structural deterioration.

  4. Evaluation of Tensile Strength of Unresin Continuous Carbon Fiber Cables as Tensile Reinforcement for Concrete Structures

    OpenAIRE

    Ohta, Toshiaki; Djamaluddin, rudy; Seo, SungTag; Sajima, Takao; Harada, Koji

    2002-01-01

    As a tensile reinforcement of a concrete structure member, tensile strength of Unresin Continuous Carbon Fiber (UCCF) cables should be stated clearly. It has been reported that, through direct tensile test, tensile capacity of UCCF cables ranged from 30%

  5. Investigation of Corrosion and Cathodic Protection in Reinforced Concrete. II: Properties of Steel Surface Layers

    NARCIS (Netherlands)

    Koleva, D.A.; De Wit, J.H.W.; Van Breugel, K.; Lodhi, Z.F.; Ye, G.

    2007-01-01

    The present study explores the formation of corrosion products on the steel surface (using as-received low carbon construction steel) in reinforced concrete in conditions of corrosion and subsequent transformation of these layers in conditions of cathodic protection (CP).

  6. Effect of steel reinforcement with different degree of corrosion on degeneration of mechanical performance of reinforced concrete frame joints

    Directory of Open Access Journals (Sweden)

    Wu Xu

    2016-02-01

    Full Text Available Beam-column joints which shoulders high-level and vertical shearing effect that maintains balance of beam and column end is the major component influencing the performance of the whole framework. Post earthquake investigation suggests that collapse of frame structure is induced by failure of joints in most cases. Thus, beam-column joints must have strong bearing capacity and good ductility, and reinforced concrete structure just meets the above requirement. But corrosion caused by long time use of reinforced concrete framework will lead to degeneration of mechanical performance of joints. To find out the rule of effect of steel reinforcement with different corrosion rate on degeneration of bearing capacity of reinforced concrete framework joints, this study made a nonlinear numerical analysis on fifteen models without stirrup in the core area of reinforced concrete frame joints using displacement method considering axial load ratio of column end and constraint condition. This work aims to find out the key factor that influences mechanical performance of joints, thus to provide a basis for repair and reinforcement of degenerated framework joints.

  7. Rupture Directivity Effect on Seismic Vulnerability of Reinforced Concrete Bridge

    Science.gov (United States)

    Shirazian, Shadi; Nouri, Gholamreza; Ghayamghamian, Mohamadreza

    2017-04-01

    Earthquake catastrophes menace humans` lives and assets. Although earthquakes are inevitable, damage is not. To remedy this situation, significant amount of research is conducted in order to assess the performance of existent man-made structures, particularly infrastructures such as bridges which play a vital role in post earthquake services. The results can be used for assessing retrofit prioritization for structures and as a basis for economic loss estimations. The research presented here determines the vulnerability of a common typical two-span reinforced concrete bridge by generating fragility curves. Near-fault ground motions are different from ordinary ground motions, often containing strong coherent dynamic long-period pulses and permanent ground displacements. Here special attention is given to this type of ground motions, and their effects on the seismic behavior of structure are compared with ordinary motions. The results show near-fault ground motions exacerbate the seismic vulnerability of a bridge by about 68% in comparison with near-field ground motions. In other words, near-source ground motions with forward directivity effect are more dangerous.

  8. Modelling Blast Effects on a Reinforced Concrete Bridge

    Directory of Open Access Journals (Sweden)

    Markellos Andreou

    2016-01-01

    Full Text Available The detailed investigation of blast phenomena and their catastrophic effects on existing structures are the main objectives of the present paper. It is well known that blast phenomena may be characterized by significant complexity, often involving complicated wave propagation effects as well as distinguishable material behaviors. Considering the above and in an attempt to provide a simplified modelling approach for the simulation of blast effects, a novel procedure is presented herein based on well-established methodologies and common engineering practices. In the above framework, firstly, the “predominant” deformation shape of the structure is estimated based on elastic finite element simulations under blast loads and then the structural response of the system is evaluated as a result of common computational beam-element tools such as displacement-based pushover analysis. The proposed methodology provides an immediate first estimation of the structural behavior under blast loads, based on familiar engineering procedures. A two-span reinforced concrete bridge was thoroughly investigated and the results provide insightful information regarding the damage patterns and localization.

  9. Using New Coating Materials for Corrosion Prevention of Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Elshami Ahmed

    2014-04-01

    Full Text Available Deterioration of reinforcing concrete structures is a common problem among all the Mediterranean countries. To protect steel from corrosion, cobalt oxide with zinc oxide were successfully deposited on silica and alumina layer according to Core–shell theory. This theory based on depositing a surface layer of expensive efficient anticorrosive coating on a cheap extender expressing the bulk. The combination of both core and shell compounds led to the production of new coating with improved properties different from each of its individual components. These improved properties lead to change in the efficiency of protection properties of coating films containing these new coating. The objective of the present work is to prepare a new ecologically friendly natural and inorganic coating of Egyptian mix (kaolin and ceramic waste and zinc phosphate as corrosion inhibitors based on the solid–solid interaction to protect steel from corrosion in buildings construction. The results revealed that these new coating gives the best results in protecting steel substrates from corrosion especial in aggressive environment.

  10. Aftershock collapse vulnerability assessment of reinforced concrete frame structures

    Science.gov (United States)

    Raghunandan, Meera; Liel, Abbie B.; Luco, Nicolas

    2015-01-01

    In a seismically active region, structures may be subjected to multiple earthquakes, due to mainshock–aftershock phenomena or other sequences, leaving no time for repair or retrofit between the events. This study quantifies the aftershock vulnerability of four modern ductile reinforced concrete (RC) framed buildings in California by conducting incremental dynamic analysis of nonlinear MDOF analytical models. Based on the nonlinear dynamic analysis results, collapse and damage fragility curves are generated for intact and damaged buildings. If the building is not severely damaged in the mainshock, its collapse capacity is unaffected in the aftershock. However, if the building is extensively damaged in the mainshock, there is a significant reduction in its collapse capacity in the aftershock. For example, if an RC frame experiences 4% or more interstory drift in the mainshock, the median capacity to resist aftershock shaking is reduced by about 40%. The study also evaluates the effectiveness of different measures of physical damage observed in the mainshock-damaged buildings for predicting the reduction in collapse capacity of the damaged building in subsequent aftershocks. These physical damage indicators for the building are chosen such that they quantify the qualitative red tagging (unsafe for occupation) criteria employed in post-earthquake evaluation of RC frames. The results indicated that damage indicators related to the drift experienced by the damaged building best predicted the reduced aftershock collapse capacities for these ductile structures.

  11. Radiation exposure inside reinforced concrete buildings at Nagasaki

    Energy Technology Data Exchange (ETDEWEB)

    Rhoades, W.A.; Childs, R.L.; Ingersoll, D.T.

    1989-05-01

    The biological effects on the residents of Hiroshima and Nagasaki due to initial-irradiation exposure during the nuclear attacks of World War II was recognized immediately as an important source of information. After the war, an extensive effort gathered data concerning the locations of individuals at the time of the attack and their subsequent medical histories. The data from personnel located in reinforced concrete buildings are particularly significant, since large groups of occupants received radiation injury without complications due to blast and thermal effects. In order to correlate the radiation dose with physiological effects, the dose to each individual must be calculated. Enough information about the construction of the buildings was available after the war to allow a radiation transport model to be constructed, but the accurate calculation of penetration into such large, thick-walled three dimensional structures was beyond the scope of computing technology until recently. Now, the availability of Cray vector computers and the development of a specially-constructed discrete ordinates transport code, TORT, have combined to allow the successful completion of such a study. This document describes the radiation transport calculations and tabulates the resulting doses by source component and individual case location. An extensive uncertainty analysis is also included. These data are to be used in another study as input to a formal statistical analysis, resulting in a new value for the LD50 dose, i.e., the dose at which the mortality risk is 50%. 55 refs., 67 figs., 70 tabs.

  12. Application of bamboo for flexural and shear reinforcement in concrete beams

    Science.gov (United States)

    Schneider, Nathan Alan

    As the developing world is industrializing and people migrate to cities, the need for infrastructure is growing quickly and concrete has become one of the most widely used construction materials. One poor construction practice observed widely across the developing world is the minimal use of reinforcement for concrete structures due to the high cost of steel. As a low-cost, high-performance material with good mechanical properties, bamboo has been investigated as an alternative to steel for reinforcing concrete. The goal of this research is to add to the knowledge base of bamboo reinforced concrete (BRC) by investigating a unique stirrup design and testing the lap-splicing of flexural bamboo reinforcement in concrete beams. Component tests on the mechanical properties of Moso bamboo (Phyllostachys edulis) were performed, including tensile tests and pull-out tests. The results of the component tests were used to design and construct 13 BRC beams which were tested under monotonic gravity loading in 3 and 4-point bending tests. Three types of beams were designed and tested, including shear controlled, flexure controlled, and lap-spliced flexure controlled beams. The test results indicated that bamboo stirrups increased unreinforced concrete beam shear capacities by up to 259%. The flexural bamboo increased beam capacities by up to 242% with an optimal reinforcement ratio of up to 3.9%, assuming sufficient shear capacity. Limitations of the bamboo reinforcement included water absorption as well as poor bonding capability to the concrete. The test results show that bamboo is a viable alternative to steel as tensile reinforcement for concrete as it increases the ultimate capacity of the concrete, allows for high deflections and cracks, and provides warning of impending structural failure.

  13. Experimental data of the static behavior of reinforced concrete beams at room and low temperature.

    Science.gov (United States)

    Mirzazadeh, M Mehdi; Noël, Martin; Green, Mark F

    2016-06-01

    This article provides data on the static behavior of reinforced concrete at room and low temperature including, strength, ductility, and crack widths of the reinforced concrete. The experimental data on the application of digital image correlation (DIC) or particle image velocimetry (PIV) in measuring crack widths and the accuracy and precision of DIC/PIV method with temperature variations when is used for measuring strains is provided as well.

  14. Bending Moment Decrease of Reinforced Concrete Beam Supported by Additional CFRP

    Directory of Open Access Journals (Sweden)

    Mykolas Daugevičius

    2011-04-01

    Full Text Available The calculation method of reinforced concrete beam with additional CFRP composite is proposed in this article. This method estimates tangential angular concrete deformations in tensioned beam layers between steel and bonded carbon fiber reinforced polymer. The horizontal slip of CFRP composite reduce beam bending moment capacity. An additional coefficient to reduce CFRP resultant force is necessary for better precision of bending moment capacity. Also, various calculation methods of bending moment capacity are considered. Article in Lithuanian

  15. Damage detection in reinforced concrete square slabs using modal analysis and artifical neural network

    OpenAIRE

    Ahmed, MS

    2016-01-01

    Reinforced concrete (RC) structures are usually subjected to various types of loadings, such as permanent, sustained and transient during their lifetime. Reinforced concrete slabs are one of the most fundamental structural elements in buildings and bridges, which might be exposed to unfavourable conditions such as, impaired quality control, lack of maintenance, adverse environmental effects, and inadequate initial design. Therefore, the resistant capacity of the affected elements would dramat...

  16. Experimental data of the static behavior of reinforced concrete beams at room and low temperature

    Directory of Open Access Journals (Sweden)

    M. Mehdi Mirzazadeh

    2016-06-01

    Full Text Available This article provides data on the static behavior of reinforced concrete at room and low temperature including, strength, ductility, and crack widths of the reinforced concrete. The experimental data on the application of digital image correlation (DIC or particle image velocimetry (PIV in measuring crack widths and the accuracy and precision of DIC/PIV method with temperature variations when is used for measuring strains is provided as well.

  17. Blast Design of Reinforced Concrete and Masonry Components Retrofitted with FRP

    Science.gov (United States)

    2010-07-01

    ultimate flexural and shear resistance of the upgraded walls. The methodology for estimating the flexural resistance of concrete and masonry components...recommended value not including any environmental effects or debonding The FRP reinforcement is typically applied to a concrete or masonry wall...have enough tensile and shear strength to transfer the force and develop the strength of the bonded FRP reinforcement . The durability of the

  18. The use of a sacrificial zinc anode for cathodic protection of steel in reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    Hartman, R.B.; Hillier, W.H. [3M Co., St. Paul, MN (United States)

    1997-12-01

    The problem of corrosion of the reinforcing steel in concrete is recognized as a worldwide problem. In particular, these is extensive corrosion in residential and commercial balconies in tropical, coastal areas of the US, especially in Florida. A system of cathodic protection of reinforcing steel in concrete utilizing a sacrificial zinc anode and ionically conductive adhesive is described. Installation and monitoring of two condominium balconies in south Florida will be described, including instant-off and depolarization measurements over 18 months.

  19. Strengthening of concrete structures using carbon fibre reinforced polymers and cement-based adhesives

    OpenAIRE

    Hashemi, Siavash

    2017-01-01

    The research project conducted in this study concerns the investigation of the application of cement-based adhesives in CFRP strengthening of reinforced concrete members. The results demonstrate that mineral-based adhesives can provide the desired matrices for CFRP reinforcement. The literature review covers the background of CFRP application with conventional techniques. The bond characteristics of CFRP to concrete substrate, the flexural performance of retrofitted RC beams, and the fa...

  20. Combination Of The Non-Destructive Methods For Evaluating The Quality Of Concrete Used In Structures In Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Mr. R. OBAD

    2014-12-01

    Full Text Available The study is aboutthe use and comparison of three non-destructive methods (dynamic auscultation, sclerometric auscultation and auscultation by RADAR (Radio Detecting and Ranging to monitor and assess the quality of concrete. Samples of reinforced concrete panels, dimensions 200x100x30 cm of concrete dosed at 350 kg/m3 with diverse E/C ratio were achieved, conserved in the laboratory and subjected to various non-destructive test. The synthesis of the results obtained by auscultation RADAR shows a decrease in the propagation speed of the electromagnetic wave with an increase of the E/C ratio and a decrease in resistance of concrete values measured and confirmed by other non-destructive techniques (sclerometric and dynamic auscultations. This shows that more the dielectric constant is high, morethe concrete resistance is reduced, and conversely the opposite.

  1. Bond Strength between Hybrid Fiber-Reinforced Lightweight Aggregate Concrete Substrate and Self-Compacting Concrete as Topping Layer

    Directory of Open Access Journals (Sweden)

    Slamet Widodo

    2017-01-01

    Full Text Available Structural performance evaluation of composite concrete slabs that were constructed using partially precast concreting system which utilized Hybrid Fiber-Reinforced Lightweight Aggregate Concrete (HyFRLWAC as stay in-place formwork and self-compacting concrete (SCC as topping layer was conducted in this research. This paper focused on determining the appropriate strength limit criteria of interface between two different concrete layers. The tensile strength was tested using pull-off test, while concrete cohesion was investigated based on modified bisurface shear test, and dual L-shaped shear test was used to determine the effect of normal force on the shear strength of concrete interface. Sample variants were designed based on the substrate surface conditions, compressive strength of the topping layer, and magnitude of perpendicular normal force acting on interface area. The substrate surfaces were prepared in as-placed and grooved conditions for tensile test, cohesion, and shear strength test. Test results indicate that tensile strength, cohesion, and shear strength of the concrete interface are affected by surface condition of the substrate, compressive strength of the topping layer, and the normal force acting perpendicularly on the concrete interface area. Proposed formulation for bond strength prediction between HyFRLWAC as substrate and SCC as topping layer is also presented in this paper.

  2. 77 FR 39254 - Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and...

    Science.gov (United States)

    2012-07-02

    ..., Deputy Agency Ethics Official, at 202-205-3088. Limited disclosure of business proprietary information... Ukraine; Institution of Five-Year Reviews Concerning the Antidumping Duty Orders on Steel Concrete... determine whether revocation of the antidumping duty orders on steel concrete reinforcing bar from Belarus...

  3. Shrinkage modeling of concrete reinforced by palm fibres in hot dry environments

    Science.gov (United States)

    Akchiche, Hamida; Kriker, Abdelouahed

    2017-02-01

    The cement materials, such as concrete and conventional mortar present very little resistance to traction and cracking, these hydraulic materials which induces large withdrawals on materials and cracks in structures. The hot dry environments such as: the Saharan regions of Algeria, Indeed, concrete structures in these regions are very fragile, and present high shrinkage. Strengthening of these materials by fibers can provide technical solutions for improving the mechanical performance. The aim of this study is firstly, to reduce the shrinkage of conventional concrete with its reinforcement with date palm fibers. In fact, Algeria has an extraordinary resources in natural fibers (from Palm, Abaca, Hemp) but without valorization in practical areas, especially in building materials. Secondly, to model the shrinkage behavior of concrete was reinforced by date palm fibers. In the literature, several models for still fiber concrete were founded but few are offers for natural fiber concretes. To do so, a still fiber concretes model of YOUNG - CHERN was used. According to the results, a reduction of shrinkage with reinforcement by date palm fibers was showed. A good ability of molding of shrinkage of date palm reinforced concrete with YOUNG - CHERN Modified model was obtained. In fact, a good correlation between experimental data and the model data was recorded.

  4. Resistance to Corrosion of Reinforcement of High Volume Fly Ash Concrete

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, S. O.; Bae, S. H.; Lee, H. J. [Andong National University, Andong (Korea, Republic of); Lee, K. M. [Sungkyunkwan University, Suwon (Korea, Republic of); Jung, S. H. [Korea Confirmity Laboratories, Seoul (Korea, Republic of)

    2014-12-15

    Due to the increasing of interest about the eco-friendly concrete, it is increased to use concretes containing by-products of industry such as fly ash(FA), ground granulated blast furnace slag(GGBFS), silica fume(SF), and etc. Especially, these are well known for improving the resistances to reinforcement corrosion in concrete and decreasing chloride ion penetration. The purpose of this experimental research is to evaluate the resistance against corrosion of reinforcement of high volume fly ash(HVFA) concrete which is replaced with high volume fly ash for cement volume. For this purpose, the concrete test specimens were made for various strength level and replacement ratio of FA, and then the compressive strength and diffusion coefficient for chloride ion of them were measured for 28, 91, and 182 days, respectively. Also, corrosion monitoring by half cell potential method was carried out for the made lollypop concrete test specimens to detect the time of corrosion initiation for reinforcement in concrete. As a result, it was observed from the test results that the compressive strength of HVFA concrete was decreased with increasing replacement ratio of FA but long-term resistances against reinforcement corrosion and chloride ion penetration of that were increased.

  5. The Relationship between Rebar-Debonding and Cracking in Reinforced Concrete

    DEFF Research Database (Denmark)

    Thybo, Anna Emilie A.; Stang, Henrik; Olesen, John Forbes

    2012-01-01

    A mechanical model has been used to evaluate the rebar-concrete debonding length and Crack Mouth Opening Displacement (CMOD) in reinforced concrete. The modelling is based on the theory of the fictitious crack. It is shown that there is a non-trival relationship between the debonding length...

  6. The role of concrete resistivity in chloride-induced macro-cell corrosion of reinforcement

    OpenAIRE

    Hornbostel, Karla

    2015-01-01

    Norwegian concrete structures are exposed to salt contamination from both sea water and de-icing salts. Chlorides penetrate the concrete cover and initiate corrosion of the reinforcement. The deterioration process can propagate at high rates and endanger serviceability and structural safety. Concrete resistivity is usually assumed to correlate closely with the corrosion process, and its measurement is in principle simple and costefficient, and widely recommended to support serv...

  7. Concrete mechanics. Part A: Theory and experiments on the mechanical behavior of cracks in plain and reinforced concrete subjected to shear loading

    Science.gov (United States)

    Walraven, J. C.; Reinhardt, H. W.

    The mechanism or transmission of forces across cracks whose faces are subjected to shear displacements are investigated. This mechanism is achieved by interaction of several components: axial and transverse stiffness (dowel action) of the reinforcement and direct transfer of force between the rough concrete crack faces, generally denoted by the term 'aggregate interlock'. Experimental research and the derivation of a theoretical model gave insight into the phenomenon. Tests were carried out on precracked shear specimens. Variables in the tests were the type of reinforcement (embedded reinforcing bars, external restraint bars), the concrete strength, the type of the concrete (sand gravel concrete, lightweight concrete), the grading of the concrete (continuous discontinuous), the scale of the concrete, and the initial crack width. Measurements were carried for determining the shear force, the crack displacements and, for the specimens with external reinforcement, the force in the restraining bars.

  8. Analysis of concrete targets with different kinds of reinforcements subjected to blast loading

    Science.gov (United States)

    Oña, M.; Morales-Alonso, G.; Gálvez, F.; Sánchez-Gálvez, V.; Cendón, D.

    2016-05-01

    In this paper we describe an experimental campaign carried out to study and analyse the behaviour of concrete slabs when subjected to blast loading. Four different types of concrete have been tested: normal strength concrete with steel rebar, normal strength concrete with steel rebar retrofitted with Kevlar coating, steel fibre reinforced concrete (SFRC) and polypropylene fibre reinforced concrete (PFRC). The major asset of the experimental setup used is that it allows to subject up to four specimens to the same blast load what, besides being cost effective, makes possible to have a measure of the experimental scatter. The results of SFRC and PFRC concretes have been analysed by using a previously developed material model for the numerical simulation of concrete elements subjected to blast. The experimental campaign and preliminary results of this numerical analysis show how the high strain rates, in spite of improving the mechanical properties of these kinds of fibre reinforced concretes, lead to an embrittlement of the material, which may be dangerous from the point of view of the structural behaviour.

  9. Bond characteristics of steel fiber and deformed reinforcing steel bar embedded in steel fiber reinforced self-compacting concrete (SFRSCC)

    Science.gov (United States)

    Aslani, Farhad; Nejadi, Shami

    2012-09-01

    Steel fiber reinforced self-compacting concrete (SFRSCC) is a relatively new composite material which congregates the benefits of the self-compacting concrete (SCC) technology with the profits derived from the fiber addition to a brittle cementitious matrix. Steel fibers improve many of the properties of SCC elements including tensile strength, ductility, toughness, energy absorption capacity, fracture toughness and cracking. Although the available research regarding the influence of steel fibers on the properties of SFRSCC is limited, this paper investigates the bond characteristics between steel fiber and SCC firstly. Based on the available experimental results, the current analytical steel fiber pullout model (Dubey 1999) is modified by considering the different SCC properties and different fiber types (smooth, hooked) and inclination. In order to take into account the effect of fiber inclination in the pullout model, apparent shear strengths (τ (app)) and slip coefficient (β) are incorporated to express the variation of pullout peak load and the augmentation of peak slip as the inclined angle increases. These variables are expressed as functions of the inclined angle (ϕ). Furthurmore, steel-concrete composite floors, reinforced concrete floors supported by columns or walls and floors on an elastic foundations belong to the category of structural elements in which the conventional steel reinforcement can be partially replaced by the use of steel fibers. When discussing deformation capacity of structural elements or civil engineering structures manufactured using SFRSCC, one must be able to describe thoroughly both the behavior of the concrete matrix reinforced with steel fibers and the interaction between this composite matrix and discrete steel reinforcement of the conventional type. However, even though the knowledge on bond behavior is essential for evaluating the overall behavior of structural components containing reinforcement and steel fibers

  10. Application of artificial neural networks to predict the deflections of reinforced concrete beams

    Science.gov (United States)

    Kaczmarek, Mateusz; Szymańska, Agnieszka

    2016-06-01

    Nonlinear structural mechanics should be taken into account in the practical design of reinforced concrete structures. Cracking is one of the major sources of nonlinearity. Description of deflection of reinforced concrete elements is a computational problem, mainly because of the difficulties in modelling the nonlinear stress-strain relationship of concrete and steel. In design practise, in accordance with technical rules (e.g., Eurocode 2), a simplified approach for reinforced concrete is used, but the results of simplified calculations differ from the results of experimental studies. Artificial neural network is a versatile modelling tool capable of making predictions of values that are difficult to obtain in numerical analysis. This paper describes the creation and operation of a neural network for making predictions of deflections of reinforced concrete beams at different load levels. In order to obtain a database of results, that is necessary for training and testing the neural network, a research on measurement of deflections in reinforced concrete beams was conducted by the authors in the Certified Research Laboratory of the Building Engineering Institute at Wrocław University of Science and Technology. The use of artificial neural networks is an innovation and an alternative to traditional methods of solving the problem of calculating the deflections of reinforced concrete elements. The results show the effectiveness of using artificial neural network for predicting the deflection of reinforced concrete beams, compared with the results of calculations conducted in accordance with Eurocode 2. The neural network model presented in this paper can acquire new data and be used for further analysis, with availability of more research results.

  11. Demonstration and Validation of a Lightweight Composite Bridge Deck Technology as an Alternative to Reinforced Concrete

    Science.gov (United States)

    2016-08-01

    78 Figure 103. Extensive missing grout revealed after steel strips removed. .......................... 79 Figure 104. Grout leaking through caulk...ERDC/CERL TR-16-16 79 Figure 103. Extensive missing grout revealed after steel strips removed. Figure 104. Grout leaking through caulk. ERDC...Abstract Cyclic loading and weathering of reinforced concrete bridge decks cause corrosion of reinforcement steel , which leads to cracking, potholes

  12. Articularities of Analysis and Behaviour of Concrete Beams Reinforced with Fibrous Polymer Composite Bars

    Directory of Open Access Journals (Sweden)

    N. Ţăranu

    2006-01-01

    Full Text Available Traditional steel based reinforcement systems for concrete elements are facing with serious problems mainly caused by corrosion due to chemically aggressive environments and salts used in deicing procedures, especially in case of bridge steel reinforced concrete girders. Also in some cases special applications require structural members with magnetic transparency. An alternative to this major problem has recently become the use of fiber reinforced polymer (FPR composite bars as internal reinforcement for concrete beams. The particularities of their mechanical properties are making the design process a difficult task for engineers, numerous research centers being involved in correcting this situation. The general aspects concerning the conceiving of FR.P reinforced concrete beams are firstly analyzed, compared to those reinforced with steel bars. Some results of a Finite Element Analysis, as part of a complex program which also implies full scale testing of FRP reinforced beams subjected to bending, are given and discussed in the paper. The low elasticity modulus presented by glass fiber reinforced polymer (GFRP bars does not justify its use from structural point of view when deflection is the limiting condition but for corrosive resistance reasons and special electromagnetic properties this system can be promoted.

  13. Assessment of cracks in reinforced concrete by means of electrical resistance and image analysis

    NARCIS (Netherlands)

    Pacheco, J.; Šavija, B.; Schlangen, E.; Polder, R.B.

    2014-01-01

    The durability of cracked reinforced concrete is a serious concern in the construction industry. Cracks represent fast routes for chloride penetration, which can result in reinforcement corrosion. Bending or tapered cracks have the characteristic of being wider at the surface and becoming narrower t

  14. Influence of Basalt FRP Mesh Reinforcement on High-Performance Concrete Thin Plates at High Temperatures

    DEFF Research Database (Denmark)

    Hulin, Thomas; Lauridsen, Dan H.; Hodicky, Kamil;

    2015-01-01

    A basalt fiber–reinforced polymer (BFRP) mesh was introduced as reinforcement in high-performance concrete (HPC) thin plates (20–30 mm) for implementation in precast sandwich panels. An experimental program studied the BFRP mesh influence on HPC exposed to high temperature. A set of standard furn...

  15. Numerical Determination of Shear Strength of Steel Reinforced Concrete Column Strengthened by CFRP Sheets

    Institute of Scientific and Technical Information of China (English)

    王铁成; 余流; 王立军

    2003-01-01

    The earthquake-resistant property of reinforced concrete members depends on the interaction between reinforcing bars and surrounding concrete through bond to a large degree. In this paper a general system aimed at dealing with the failure analysis of reinforced concrete columns strengthened with carbon-fiber-reinforced plastic (CFRP) sheets including bond-slip of the anchored reinforcing bars at the foot of the columns is presented. It is based on the yield design theory with a mixed modeling of the structure, according to which the concrete material is treated as a classical two-dimensional continuum, whereas the longitudinal reinforcing bars are regarded as one-dimensional rods including bond-slip at the foot of the columns. In shear reinforced zones both the shear CFRP sheets and transverse reinforcing bars are incorporated in the analysis through a homogenization procedure and they are only in tension. The approach is then implemented numerically by means of the finite-element formulation. The numerical procedure produces accurate estimates for the loading-carrying capacity of the shear members taken as an illustrative application by correlation with the experimental results, so the proposed approach is valid.

  16. Review of Japanese recommendations on design and construction of different classes of fiber reinforced concrete and application examples

    DEFF Research Database (Denmark)

    Uchida, Yuichi; Fischer, Gregor; Hishiki, Yoshihiro

    2008-01-01

    Reinforced Cement Composites (HPFRCC) with strain hardening and multiple cracking behavior, and Ultra High-strength Fiber Reinforced concrete (UFC) with increased tensile strength. The recommendations on the design, production, and application of these classes of fiber reinforced concrete have been...

  17. An application of asymmetrical glass fibre-reinforced plastics for the manufacture of curved fibre reinforced concrete

    OpenAIRE

    Funke, Henrik; Gelbrich, Sandra; Ulke-Winter , Lars; Kroll, Lothar; Petzoldt, Carolin

    2015-01-01

    There was developed a novel technological and constructive approach for the low-cost production of curved freeform formworks, which allow the production of single and double-curved fibre reinforced concrete. The scheduled approach was based on a flexible, asymmetrical multi-layered formwork system, which consists of glass-fibre reinforced plastic (GFRP). By using of the unusual anisotropic structural behavior, these GFRP formwork elements permitted a specific adjustment of defined curvature. ...

  18. Calculating the Carrying Capacity of Flexural Prestressed Concrete Beams with Non-Metallic Reinforcement

    Directory of Open Access Journals (Sweden)

    Mantas Atutis

    2011-04-01

    Full Text Available The article reviews moment resistance design methods of prestressed concrete beams with fibre-reinforced polymer (FRP reinforcement. FRP tendons exhibit linear elastic response to rupture without yielding and thus failure is expected to be brittle. The structural behaviour of beams prestressed with FRP tendons is different from beams with traditional steel reinforcement. Depending on the reinforcement ratio, the flexural behaviour of the beam can be divided into several groups. The numerical results show that depending on the nature of the element failure, moment resistance calculation results are different by using reviewed methods. It was found, that the use of non-metallic reinforcement in prestressed concrete structures is effective: moment capacity is about 5% higher than that of the beams with conventional steel reinforcement.Article in Lithuanian

  19. Crack elongation and its width of large depth reinforced concrete beams

    Institute of Scientific and Technical Information of China (English)

    GUAN Jun-feng; ZHAO Shun-bo; HUANG Cheng-kui

    2010-01-01

    In order to meet the requirement of structural inspection,the crack spacing and crack width at various heights in the tensile zone of six large depth reinforced concrete beams were measured under several loading levels of serviceability state.The effects of the depth of normal section beams on the crack spacing and crack width were analyzed,and the modified model is proposed for calculating the average crack spacing by thinking about the depth of normal section,the reinforcement arrangement and the effective reinforcement ratio.The relationships of crack widths at any position in the tensile zone and at the reinforcement level on the side surface of beam were studied.By theoretical and statistical analysis,a method is proposed to calculate the ratios of crack widths between any position and the reinforcement level on the side surface of large depth reinforced concrete beams.

  20. Tensile properties of glass/natural jute fibre-reinforced polymer bars for concrete reinforcement

    Science.gov (United States)

    Han, J. W.; Lee, S. K.; Kim, K. W.; Park, C. G.

    2015-12-01

    The tensile performance of glass/natural jute fibre-reinforced polymer (FRP) bar, intended for concrete reinforcement was evaluated as a function of volume fraction of natural jute fibre. Natural jute fibre, mixed at a ratio of 7:3 with vinyl ester, was surface-treated with a silane coupling agent and used to replaced glass fibre in the composite in volume fractions of 0%, 30%, 50%, 70%, and 100%. The tensile load-displacement curve showed nearly linear elastic behaviour up to 50% natural jute fibre, but was partially nonlinear at a proportion of 70%. However, the glass/natural jute FRP bars prepared using 100% natural jute fibre showed linear elastic behaviour. Tensile strength decreased as the natural jute fibre volume fraction increased because the tensile strength of natural jute fibre is much lower than that of glass fibre (about 1:8.65). The degree of reduction was not proportional to the natural jute fibre volume fraction due to the low density of natural jute fibre (1/2 that of glass fibre). Thus, as the mix proportion of natural jute fibre increased, the amount (wt%) and number of fibres used also increased.

  1. Strain Sharing Assessment in Woven Fiber Reinforced Concrete Beams Using Fiber Bragg Grating Sensors.

    Science.gov (United States)

    Montanini, Roberto; Recupero, Antonino; De Domenico, Fabrizio; Freni, Fabrizio

    2016-09-22

    Embedded fiber Bragg grating sensors have been extensively used worldwide for health monitoring of smart structures. In civil engineering, they provide a powerful method for monitoring the performance of composite reinforcements used for concrete structure rehabilitation and retrofitting. This paper discusses the problem of investigating the strain transfer mechanism in composite strengthened concrete beams subjected to three-point bending tests. Fiber Bragg grating sensors were embedded both in the concrete tensioned surface and in the woven fiber reinforcement. It has been shown that, if interface decoupling occurs, strain in the concrete can be up to 3.8 times higher than that developed in the reinforcement. A zero friction slipping model was developed which fitted very well the experimental data.

  2. Effectiveness of concrete to protect steel reinforcement from corrosion in marine structures

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    A laboratory evaluation of how variations in cover design and properties determine its effectiveness in controlling corrosion in reinforced concretes in marine structures is described. The effect of concrete type and composition on chloride ingress and corrosion rate was studied for four simulated marine environments. Contrary to expectation, significant corrosion did not take place in reinforcement placed at 30 mm cover after 30 months exposure, even in concretes of lower strengths and higher water/cement ratios than mixes employed in the North Sea. Unexpected crevice corrosion let to the exclusion of electrochemical data and restricted the opportunity of correlating the properties of the cover with the onset and rate of corrosion of reinforcement. The project did, however, provide valuable data on in situ strength, moisture content, permeability, resistivity, carbonation and rate of chloride ingress. Limited data is also available on the pore structure of the cover and its oxygen diffusion characteristics. It is emphasised that all results refer to uncracked concrete. (author).

  3. Minimum Reinforcement in Concrete Structures under Restrained Shrinkage and Thermal Actions

    DEFF Research Database (Denmark)

    Christiansen, Morten Bo; Nielsen, Mogens Peter

    1999-01-01

    The present paper deals with minimum reinforcement to ensure limitation of crack widths in concrete structures subjected to small imposed strains, such as those from restrained shrinkage or thermal actions. A theory is presented, which models the behaviour of a tensile member from zero load...... to first yielding of reinforcement. The theory takes into account the formation of each crack. However, concluding the paper, a simple design formula is given, which provides the amount of reinforcement, necessary to ensure a given crack width....

  4. The 2011 Earthquake in Simav, Turkey and Seismic Damage to Reinforced Concrete Buildings

    Directory of Open Access Journals (Sweden)

    Yücel Güney

    2013-02-01

    Full Text Available Reinforced concrete buildings suffered significant damage in the region affected by the 29 May 2011 earthquake in Simav (Kutahya, Turkey. Typical building damage is classified and potential causes of damage are investigated. Reinforced concrete moment resisting frames with hollow brick infill walls are the most common structural system in and around the Simav city center while masonry construction is common in rural areas. Although the Simav earthquake, with a magnitude of 5.7 to 5.9, can be classified as a moderate earthquake, many buildings experienced damage varying from frequent diagonal cracking and brittle failure of infill walls to collapse or severe damage to frames due to short columns, soft stories or other reasons including insufficient or poor detailing of reinforcement. This study investigates and presents the seismicity of the region, characteristics of the measured ground motions, seismic load demands including response spectra, and damage mechanisms, potential causes and classification of observed damage in reinforced concrete buildings.

  5. Heavy vehicle simulator (HVS) evaluation of load transfer efficiency and continuously reinforced concrete inlays on the N3 near Pietermartizburg

    CSIR Research Space (South Africa)

    Du Plessis, L

    2006-07-01

    Full Text Available The paper addresses two different heavy Vehicle Simulator (HVS) studies conducted on concrete: Load transfer through aggregate interlock and the use of dowels and the evaluation of the performance of an in-service continuously reinforced concrete...

  6. Impact of rockfill deformation on stress-strain state on dam reinforced concrete face

    Directory of Open Access Journals (Sweden)

    Sainov Mikhail Petrovich

    2015-03-01

    Full Text Available The author considered the results of the numerical studies of stress-strain state of a 100 m high rockfill dam with a reinforced concrete face. In the analysis, the dam construction sequence and loads applied to it were considered; it was assumed that the reinforced concrete face was constructed after filling the dam. The calculations were carried out in the elastic formulation at various moduli of deformation and Poisson’s ratio. It was revealed that at rockfill settlement under the action of hydrostatic pressure the reinforced concrete face not only bends but also is subject to longitudinal force. The development of these forces is connected not only with rockfill shear deformation in horizontal direction. Depending on the value of rockfill Poisson’s ratio these longitudinal forces may be both compressive and tensile. At the Poisson’s ratio exceeding 0.25 the longitudinal forces are tensile, and when it is equal to 0.2 - they are compressive. Evidently these particular longitudinal forces are the course of crack formation in reinforced concrete faces of a number of constructed dams. The indirect confirmation of the development of tensile forces on the face is the fact that actually in all the dams with reinforced concrete face opening of perimeter joint was observed. Thus, in order to provide the strength of reinforced concrete it is important to increase rockfill shear modulus. Only the decrease of stone compressibility (i.e. increase of linear deformation modulus E will slightly improve the stress state of the face, as the value of E has less effect on settlements and shear of the dam than Poisson’s ratio. High rockfill dams with reinforced concrete face may have a favorable stress state only at narrow site when the face horizontal displacements are inconsiderable and due to the settlements of rockfill in the face the forces are compressive but not tensile longitudinal forces.

  7. Uniaxial Tension Test of Slender Reinforced Early Age Concrete Members

    Directory of Open Access Journals (Sweden)

    Wenbo Zhang

    2011-08-01

    Full Text Available The present study aims to obtain the tensile properties of early age concrete based on a uniaxial tension test employing RC slender members. First, the paper shows that concrete strain is equal to the strain of rebar at the mid-span of the RC member. The tensile Young’s modulus and the strain capacity of early age concrete are estimated using strain measurements. The experiment indicated that the tensile Young’s modulus at an early age is higher than the compressive modulus. This observation was similar to one found in a previous investigation which used a direct tension test of early age concrete. Moreover, the paper describes how an empirical equation for mature concrete can be applied to the relation between uniaxial tensile strength and splitting tensile strength even in early age concrete. Based on a uniaxial tension test, the paper proposes an empirical equation for the relationship between standard bond stresses and relative slip.

  8. Reinforced concrete corrosion: application of Bayesian networks to the risk management of cooling towers in nuclear plants; Corrosion du beton arme: application des reseaux bayesiens a la gestion du risque des aerorefrigerants des centrales nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Capra, B.; Le Drogo, J.; Wolff, V. [OXAND S.A., 77 - Avon (France)

    2007-07-01

    Degradation modeling of concrete structures uses uncertain variables and leads, using reliability assessment, to time dependant evolution of failure probabilities. However, only few data are generally available to feed models leading to two types of uncertainties: an intrinsic one depending on the modeled phenomena and one related to the precision of the measurements. Each new data available is a piece of information which allows updating the initial prediction. In this article, an example of updating process, based on a Bayesian network, is presented and applied on the corrosion risk of a cooling tower in a nuclear plant. (authors)

  9. Bamboo Reinforced Concrete Truss Bridge for Rural Infrastructure

    OpenAIRE

    D. Nuralinah; S. M. Dewi

    2014-01-01

    Bamboo is one of a potential renewable construction material in the village. Bamboo is known to have a high mechanical strength in direction of the fibers. The weakness of bamboo in lateral direction of the fiber could be solved by constructing a composite structure with the concrete. The appropriate construction with hold the loads in axial direction is a truss structure. In a bamboo concrete truss structure, the bars are composed from the concrete column with a bamboo reinforcem...

  10. Behavior Of A Confined Tension Lap Splice In High-Strength Reinforced Concrete Beams

    Science.gov (United States)

    Abdel-Kareem, Ahmed H.; Abousafa, Hala; El-Hadidi, Omaia S.

    2015-09-01

    The results of an experimental program conducted on seventeen simply supported concrete beams to study the effect of transverse reinforcement on the behavior of the lap splice of a steel reinforcement in tension zones in high-strength concrete beams are presented. The parameters included in the experimental program were the concrete compressive strength, the lap splice length, the amount of transverse reinforcement provided within the splice region, and the shape of the transverse reinforcement around the spliced bars. The experimental results showed that the displacement ductility increased and the mode of failure changed from a splitting bond failure to a flexural failure when the amount of the transverse reinforcement in the splice region increased, and the compressive strength increased up to 100 MPa. The presence of the transverse reinforcement around the spliced bars had a pronounced effect on increasing the ultimate load, the ultimate deflection, and the displacement ductility. The prediction of maximum steel stresses for spliced bars using the ACI 318-05 building code was compared with the experimental results. The comparison showed that the effect of the transverse reinforcement around spliced bars has to be considered into the design equations for lap splice length in high-strength concrete beams.

  11. Strength and deformability of concrete beams reinforced by non-metallic fiber and composite rebar

    Science.gov (United States)

    Kudyakov, K. L.; Plevkov, V. S.; Nevskii, A. V.

    2015-01-01

    Production of durable and high-strength concrete structures with unique properties has always been crucial. Therefore special attention has been paid to non-metallic composite and fiber reinforcement. This article describes the experimental research of strength and deformability of concrete beams with dispersed and core fiber-based reinforcement. As composite reinforcement fiberglass reinforced plastic rods with diameters 6 mm and 10 mm are used. Carbon and basalt fibers are used as dispersed reinforcement. The developed experimental program includes designing and production of flexural structures with different parameters of dispersed fiber and composite rebar reinforcement. The preliminary testing of mechanical properties of these materials has shown their effectiveness. Structures underwent bending testing on a special bench by applying flexural static load up to complete destruction. During the tests vertical displacements were recorded, as well as value of actual load, slippage of rebars in concrete, crack formation. As a result of research were obtained structural failure and crack formation graphs, value of fracture load and maximum displacements of the beams at midspan. Analysis of experimental data showed the effectiveness of using dispersed reinforcement of concrete and the need for prestressing of fiberglass composite rebar.

  12. Modeling of concrete cracking due to corrosion process of reinforcement bars

    Energy Technology Data Exchange (ETDEWEB)

    Bossio, Antonio, E-mail: antonio.bossio@unina.it [Department of Chemical Engineering, Materials and Production, University of Naples “Federico II”, Napoli, Piazzale V. Tecchio 80, I-80125 Italy (Italy); Monetta, Tullio, E-mail: monetta@unina.it [Department of Chemical Engineering, Materials and Production, University of Naples “Federico II”, Napoli, Piazzale V. Tecchio 80, I-80125 Italy (Italy); Bellucci, Francesco, E-mail: bellucci@unina.it [Department of Chemical Engineering, Materials and Production, University of Naples “Federico II”, Napoli, Piazzale V. Tecchio 80, I-80125 Italy (Italy); Lignola, Gian Piero, E-mail: glignola@unina.it [Department of Structures for Engineering and Architecture, University of Naples “Federico II”, Via Claudio 21, I-80125 Napoli (Italy); Prota, Andrea, E-mail: aprota@unina.it [Department of Structures for Engineering and Architecture, University of Naples “Federico II”, Via Claudio 21, I-80125 Napoli (Italy)

    2015-05-15

    The reinforcement corrosion in Reinforced Concrete (RC) is a major reason of degradation for structures and infrastructures throughout the world leading to their premature deterioration before design life was attained. The effects of corrosion of reinforcement are: (i) the reduction of the cross section of the bars, and (ii) the development of corrosion products leading to the appearance of cracks in the concrete cover and subsequent cover spalling. Due to their intrinsic complex nature, these issues require an interdisciplinary approach involving both material science and structural design knowledge also in terms on International and National codes that implemented the concept of durability and service life of structures. In this paper preliminary FEM analyses were performed in order to simulate pitting corrosion or general corrosion aimed to demonstrate the possibility to extend the results obtained for a cylindrical specimen, reinforced by a single bar, to more complex RC members in terms of geometry and reinforcement. Furthermore, a mechanical analytical model to evaluate the stresses in the concrete surrounding the reinforcement bars is proposed. In addition, a sophisticated model is presented to evaluate the non-linear development of stresses inside concrete and crack propagation when reinforcement bars start to corrode. The relationships between the cracking development (mechanical) and the reduction of the steel section (electrochemical) are provided. Finally, numerical findings reported in this paper were compared to experimental results available in the literature and satisfactory agreement was found.

  13. An analysis of the abaca natural fiber in reinforcing concrete composites as a construction material in developing countries

    Energy Technology Data Exchange (ETDEWEB)

    Magdamo, R.V.

    1988-01-01

    This study analyzed the flexural and splitting tensile strengths and the ductility of abaca fiber-reinforced concrete composites. Abaca fibers are natural fibers of vegetable origin from the abaca plant native to the Philippine Islands. The purpose was to investigate how various volume-fractions of the abaca fiber could affect the mechanical properties of the concrete matrix. A concrete design mix containing a volume ratio of 1.0 part Type I Portland cement and 3.0 parts sand was used in the preparation of laboratory test samples. Abaca fibers were 1 to 1.5 inches long and randomly mixed with the concrete at 0.2% and 0.4% volume fractions. The fibers were not chemically treated and no admixtures were used. Samples were cast into concrete cylinders and flexural beams. Standard ASTM procedures in casting of flexural beams and concrete cylinders and the curing of 28-day concrete samples were followed. The center-point loading method of the flexural test and the splitting tensile test was utilized. Addition of abaca fibers decreased the mean flexural and splitting tensile strengths of the concrete matrices. However, ductility of the matrices increased with the addition of abaca fibers at 0.2% and 0.4% volume-fractions. The Scanning Electron Microscope (SEM) micrographs revealed that increasing the fiber volume-fraction influenced the growth rate of dehydration precipitates as CH (calcium hydroxide) crystals. At the 0.2% volume-fraction, smaller density of precipitates grew into large crystals, while at the 0.4% volume-fraction, the dehydration precipitates were much more dense, which were made up of small sized crystals. Abaca fibers in the concrete mix decreased the mean flexural and splitting tensile strengths, increased the modulus of elasticity, improved the ductility, and acted as a medium to slow down and stop the propagation of cracks.

  14. The influence of self-compacting steel fibre reinforced concrete infill on the flexure strength and ductility of masonry walls

    OpenAIRE

    Oliveira, Luiz António Pereira de; Bernardo, Luís Filipe Almeida

    2010-01-01

    This paper presents an experimental study on the influence of longitudinal reinforcement ratio and steel fibre volume in self-compacting concrete infill on the strength and ductility of reinforced masonry walls subjected to flexure. Flexure tests were performed as four-point bending tests on twelve walls. The analysis of the concrete infill contribution to the walls capacity is made considering recent recommendations for steel fibre reinforced concrete design. A ductility...

  15. Serviceability behavior of Reinforcement Concrete beams with polypropylene and steel fibers

    Directory of Open Access Journals (Sweden)

    NaserKabashi

    2015-07-01

    Full Text Available Serviceability Limit States (SLS may lead to the design of concrete elements internally reinforced with Fiber Reinforced Polymer (FRP.In many types of concrete structure loss the serviceability due to wide cracks, number of cracks or large deflection is not uncommon behaviour in concrete structures or concrete beams.The flexural ductility affects the serviceability deflection of RC beams once flexural cracking take place.Imprvement will be focused on the use of polypropilene fibres , which is the subject of thispaper. The performance of concrete with fibers is judged by the flexural toughness obtained by load-deflection curves. The flexural toughness of concrete is depend on different types of fibersin use.Its tougness will be reperesent in the behaviour of RC memebres at failure. Sometimes, it is difficult to use the flexural toughness to judge the behavior of concrete structures under service load. The result of cracking on concrete beam due to the applied load and the method of loading to monitor and check the performance of concrete with different types of fiber arediscussed in this paper. The reductionin the dimension of cracks and the effect of energy disipations of polypropilene fibres will be the main aim of this research work.

  16. Deflection analysis of reinforced concrete beams strengthened with carbon fibre reinforced polymer under long-term load action

    Institute of Scientific and Technical Information of China (English)

    Mykolas DAUGEVI(C)IUS; Juozas VALIVONIS; Gediminas MAR(C)IUKAITIS

    2012-01-01

    This paper presents the results of an experimental research on reinforced concrete beams strengthened with an external carbon fibre reinforced polymer (CFRP) layer under long-term load action that lasted for 330 d.We describe the characteristics of deflection development of the beams strengthened with different additional anchorages of the external carbon fibre composite layer during the period of interest.The conducted experiments showed that the additional anchorage influences the slip of the extemal layer with respect to the strengthened element.Thus,concrete and carbon fibre composite interface stiffness decreases with a long-term load action.Therefore,the proposed method of analysis based on the built-up-bars theory can be used to estimate concrete and carbon fibre composite interface stiffness in the case of long-term load.

  17. Feasibility of Using High-Performance Steel Fibre Reinforced Concrete for Simplifying Reinforcement Details of Critical Members

    Directory of Open Access Journals (Sweden)

    Seok-Joon Jang

    2015-01-01

    Full Text Available This paper addresses the effects of hooked-end steel fibre contents on the mechanical properties of high-performance concrete (HPC and investigates the feasibility of utilizing steel fibres to simplify the complicated reinforcement detailing of critical HPC members under high shear stress. Mechanical properties of HPCs with specified compressive strength of 60 and 100 MPa include the flow, air content, compressive strength, and flexural strength. The effectiveness of 1.50% steel fibre content on the shear behaviour of diagonally reinforced concrete coupling beam without additional transverse reinforcement was investigated to alleviate complex reinforcing details for the full section confinement of diagonal bar groups. The test results revealed the incorporation of steel fibres significantly affected the mechanical properties of the HPCs. For diagonally reinforced coupling beam (SFRCCB without additional transverse reinforcement, the addition of 1.5% steel fibre content into 60 MPa HPC coupling beam provides similar cracking and structural behaviours compared to those of diagonally reinforced coupling beam (CCB with full section confinement details. However, the ductility of SFRCCB was less than that of CCB. It is recommended that both stirrups and steel fibre should be used for fully confining the diagonal bar groups of coupling beams to achieve the ductile behaviour.

  18. Finite Element Simulation of GFRP Reinforced Concrete Beam Externally Strengthened With CFRP Plates

    Directory of Open Access Journals (Sweden)

    Salleh Norhafizah

    2017-01-01

    Full Text Available The construction technology now has become more and more advanced allowing the development of new technologies or material to replace the previous one and also solved some of the troubles confronted by construction experts. The Glass Fibre Reinforced Polymer (GFRP composite is an alternative to replace the current usage of steel as it is rust proof and stronger in terms of stiffness compared to steel. Furthermore, GFRP bars have a high strength-to-weight ratio, making them attractive as reinforcement for concrete structures. However, the tensile behavior of GFRP bars is characterized by a linear elastic stress–strain relationship up to failure and, therefore, concrete elements reinforced with GFRP reinforcement exhibit brittle failure without warning. Design codes encourage over-reinforced GFRP design since it is more progressive and leads to a less catastrophic failure with a higher degree of deformability. Moreover, because of GFRP low modulus of elasticity, GFRP reinforced concrete members exhibit larger deflections and wider cracks width than steel reinforced concrete. This aims of this paper is to developed 2D Finite Element (FE models that can accurately simulate the respond on an improvement in the deflection of GFRP reinforced concrete beam externally strengthened with CFRP plates on the tension part of beam. The prediction of flexural response according to RCCSA software was also discussed. It was observed that the predicted FE results are given similar result with the experimental measured test data. Base on this good agreement, a parametric study was the performed using the validation FE model to investigate the effect of flexural reinforcement ratio and arrangement of the beams strengthened with different regions of CFRP plates.

  19. DOUBLE CURVED SURFACE (DCS) - Case study in reinforced concrete

    DEFF Research Database (Denmark)

    Esteves, Luis Pedro; Henriques, Goncalo

    2007-01-01

    This paper deals with digital integration between design and fabrication in order to construct a complex double-curved concrete surface. This research focused on practical application of CNC technology to polyurethane (EPS), as an alternative to concrete formwork. The influence of specific EPS...

  20. Effect of Permeable Crystalline Material on Steel Reinforcement Corrosion of Concrete

    Institute of Scientific and Technical Information of China (English)

    YU Jian-ying; WANG Gui-ming

    2004-01-01

    Permeable crystalline materialcan permeate into pores and cracks of concrete and catalyze the reaction between Ca(OH) 2and unhydrated cement to generate a great quantity needle non-soluble crystals, which can stop up the pores and cracks of concrete, and increase the impermeability of concrete. This paper reported the results of a study conducted to evaluate steel reinforcement corrosion of concrete specimens uncoated and coated with permeable crystalline material as well as mixed with the permeable crystalline material. The properties evaluated for corrosion test were water impermeability, water absorption, compressive strength and potential. The results of water impermeability, water absorption, compressive strength clearly showed that the permeable crystalline material could prohibit water, any soluble salts and moisture from penetrating the concrete to cause corrosion, leaking, and other problems, and it did increase the compressive strength, which was favorable for protection of corrosion of reinforcing steel. Moreover, it was concluded from the potential-time curve that the steel reinforcement of uncoated specimen was in the state of activation whereas that of other specimens coated and mixed with the permeable crystalline material was in the state of inactivation. Above all, it was indicated that the permeable crystalline materialis very effective to protect the steel reinforcement of concrete from corrosion.

  1. Calculation of dynamic load impact on reinforced concrete arches in the ground

    Directory of Open Access Journals (Sweden)

    Barbashev Nikita Petrovich

    2016-01-01

    Full Text Available Concrete arches are widely used in the construction of underground facilities. The analysis of their work under dynamic loads (blasting, shock, seismic will improve the efficiency of design and application. The article addresses the problems of calculation of reinforced concrete arches in the ground in terms of the action of dynamic load - compression wave. The calculation is made basing on the decision of a closed system of equations that allows performing the calculation of elastic-plastic curved concrete structures under dynamic loads. Keeping in mind the properties of elastic-plastic reinforcement and concrete in the process of design variations, σ-ε diagrams are variable. The calculation is performed by the direct solution of differential equations in partial derivatives. The result is based on a system of ordinary differential equations of the second order (expressing the transverse and longitudinal oscillations of the structure and the system of algebraic equations (continuity condition of deformation. The computer program calculated three-hinged reinforced concrete arches. The structural calculations were produced by selection of the load based on the criteria of reaching the first limit state: ultimate strain of compressed concrete; ultimate strain tensile reinforcement; the ultimate deformation of the structure. The authors defined all the characteristics of the stress-strain state of the structure. The presented graphs show the change of bending moment and shear force in time for the most loaded section of the arch, the dependence of stresses and strains in concrete and reinforcement, stress changes in time for the cross-sectional height. The peculiarity of the problem is that the action of the load provokes the related dynamic forces - bending moment and longitudinal force. The calculations allowed estimating the carrying capacity of the structure using the criteria of settlement limit states. The decisive criterion was the

  2. Potential of Carbon Nanotube Reinforced Cement Composites as Concrete Repair Material

    Directory of Open Access Journals (Sweden)

    Tanvir Manzur

    2016-01-01

    Full Text Available Carbon nanotubes (CNTs are a virtually ideal reinforcing agent due to extremely high aspect ratios and ultra high strengths. It is evident from contemporary research that utilization of CNT in producing new cement-based composite materials has a great potential. Consequently, possible practical application of CNT reinforced cementitious composites has immense prospect in the field of applied nanotechnology within construction industry. Several repair, retrofit, and strengthening techniques are currently available to enhance the integrity and durability of concrete structures with cracks and spalling, but applicability and/or reliability is/are often limited. Therefore, there is always a need for innovative high performing concrete repair materials with good mechanical, rheological, and durability properties. Considering the mechanical properties of carbon nanotubes (CNTs and the test results of CNT reinforced cement composites, it is apparent that such composites could be used conveniently as concrete repair material. With this end in view, the applicability of multiwalled carbon nanotube (MWNT reinforced cement composites as concrete repair material has been evaluated in this study in terms of setting time, bleeding, and bonding strength (slant shear tests. It has been found that MWNT reinforced cement mortar has good prospective as concrete repair material since such composites exhibited desirable behavior in setting time, bleeding, and slant shear.

  3. Development of structural health monitoring and early warning system for reinforced concrete system

    Energy Technology Data Exchange (ETDEWEB)

    Iranata, Data, E-mail: iranata-data@yahoo.com, E-mail: data@ce.its.ac.id; Wahyuni, Endah [Civil Engineering Department, Institut Teknologi Sepuluh Nopember (ITS), Surabaya 60111 (Indonesia); Murtiadi, Suryawan [Civil Engineering Department, Universitas Mataram, Mataram 83125 (Indonesia); Widodo, Amien [Geophysical Engineering Department, Institut Teknologi Sepuluh Nopember (ITS), Surabaya 60111 (Indonesia); Riksakomara, Edwin; Sani, Nisfu Asrul [Information Systems Department, Institut Teknologi Sepuluh Nopember (ITS), Surabaya 60111 (Indonesia)

    2015-04-24

    Many buildings have been damaged due to earthquakes that occurred recently in Indonesia. The main cause of the damage is the large deformation of the building structural component cannot accommodate properly. Therefore, it is necessary to develop the Structural Health Monitoring System (SHMS) to measure precisely the deformation of the building structural component in the real time conditions. This paper presents the development of SHMS for reinforced concrete structural system. This monitoring system is based on deformation component such as strain of reinforcement bar, concrete strain, and displacement of reinforced concrete component. Since the deformation component has exceeded the limit value, the warning message can be sent to the building occupies. This warning message has also can be performed as early warning system of the reinforced concrete structural system. The warning message can also be sent via Short Message Service (SMS) through the Global System for Mobile Communications (GSM) network. Hence, the SHMS should be integrated with internet modem to connect with GSM network. Additionally, the SHMS program is verified with experimental study of simply supported reinforced concrete beam. Verification results show that the SHMS has good agreement with experimental results.

  4. Simulation of the Ill-Posed Problem of Reinforced Concrete Corrosion Detection Using Boundary Element Method

    Directory of Open Access Journals (Sweden)

    Syarizal Fonna

    2016-01-01

    Full Text Available Many studies have suggested that the corrosion detection of reinforced concrete (RC based on electrical potential on concrete surface was an ill-posed problem, and thus it may present an inaccurate interpretation of corrosion. However, it is difficult to prove the ill-posed problem of the RC corrosion detection by experiment. One promising technique is using a numerical method. The objective of this study is to simulate the ill-posed problem of RC corrosion detection based on electrical potential on a concrete surface using the Boundary Element Method (BEM. BEM simulates electrical potential within a concrete domain. In order to simulate the electrical potential, the domain is assumed to be governed by Laplace’s equation. The boundary conditions for the corrosion area and the noncorrosion area of rebar were selected from its polarization curve. A rectangular reinforced concrete model with a single rebar was chosen to be simulated using BEM. The numerical simulation results using BEM showed that the same electrical potential distribution on the concrete surface could be generated from different combinations of parameters. Corresponding to such a phenomenon, this problem can be categorized as an ill-posed problem since it has many solutions. Therefore, BEM successfully simulates the ill-posed problem of reinforced concrete corrosion detection.

  5. Behavior of Low Grade Steel Fiber Reinforced Concrete Made with Fresh and Recycled Brick Aggregates

    Directory of Open Access Journals (Sweden)

    Md. Shariful Islam

    2017-01-01

    Full Text Available In recent years, recycled aggregates from construction and demolition waste (CDW have been widely accepted in construction sectors as the replacement of coarse aggregate in order to minimize the excessive use of natural resources. In this paper, an experimental investigation is carried out to observe the influence of low grade steel fiber reinforcements on the stress-strain behavior of concrete made with recycled and fresh brick aggregates. In addition, compressive strength by destructive and nondestructive tests, splitting tensile strength, and Young’s modulus are determined. Hooked end steel wires with 50 mm of length and an aspect ratio of 55.6 are used as fiber reinforcements in a volume fraction of 0% (control case, 0.50%, and 1.00% in concrete mixes. The same gradation of aggregates and water-cement ratio (w/c=0.44 were used to assess the effect of steel fiber in all these concrete mixes. All tests were conducted at 7, 14, and 28 days to perceive the effect of age on different mechanical properties. The experimental results show that around 10%~15% and 40%~60% increase in 28 days compressive strength and tensile strength of steel fiber reinforced concrete, respectively, compared to those of the control case. It is observed that the effect of addition of 1% fiber on the concrete compressive strength is little compared to that of 0.5% steel fiber addition. On the other hand, strain of concrete at failure of steel fiber reinforced concrete has increased almost twice compared to the control case. A simple analytical model is also proposed to generate the ascending portions of the stress-strain curve of concrete. There exists a good correlation between the experimental results and the analytical model. A relatively ductile failure is observed for the concrete made with low grade steel fibers.

  6. Predicting method of local damage in reinforced concrete plate with absorber sandwiched between two concrete panels under hard projectile impact

    Energy Technology Data Exchange (ETDEWEB)

    Shirai, Tetsuo; Kambayashi, Atsushi; Ueda, Masatoshi [Takenaka Corp., Osaka (Japan); Ohno, Tomonori; Ishikawa, Nobutaka

    1995-07-01

    The predicting method of local damage in reinforced concrete plate with absorber sandwiched between two concrete panels (double-layered RC plate) under the impact of hard projectile is studied in this paper. The results of high-velocity impact tests to investigate the impact resistance of double-layered RC plates are reported. To evaluate quantitatively the extent of local damage, the existing formulae and the alternative predicting formulae with the multivariate analysis presented here are employed. The prediction of the proposed formulae can agree reasonably well with the actual observed damage, thus can be a useful method in impact resistant design. (author).

  7. Incremental dynamic analysis of concrete moment resisting frames reinforced with shape memory composite bars

    Science.gov (United States)

    Zafar, Adeel; Andrawes, Bassem

    2012-02-01

    Fiber reinforced polymer (FRP) reinforcing bars have been used in concrete structures as an alternative to conventional steel reinforcement, in order to overcome corrosion problems. However, due to the linear behavior of the commonly used reinforcing fibers, they are not considered in structures which require ductility and damping characteristics. The use of superelastic shape memory alloy (SMA) fibers with their nonlinear elastic behavior as reinforcement in the composite could potentially provide a solution for this problem. Small diameter SMA wires are coupled with polymer matrix to produce SMA-FRP composite, which is sought in this research as reinforcing bars. SMA-FRP bars are sought in this study to enhance the seismic performance of reinforced concrete (RC) moment resisting frames (MRFs) in terms of reducing their residual inter-story drifts while still maintaining the elastic characteristics associated with conventional FRP. Three story one bay and six story two bay RC MRF prototype structures are designed with steel, SMA-FRP and glass-FRP reinforcement. The incremental dynamic analysis technique is used to investigate the behaviors of the two frames with the three different reinforcement types under a suite of ground motion records. It is found that the frames with SMA-FRP composite reinforcement exhibit higher performance levels including lower residual inter-story drifts, high energy dissipation and thus lower damage, which are important for structures in highly seismic zones.

  8. Design aid for shear strengthening of reinforced concrete T-joints using carbon fiber reinforced plastic composites

    Science.gov (United States)

    Gergely, Ioan

    The research presented in the present work focuses on the shear strengthening of beam column joints using carbon fiber composites, a material considered in seismic retrofit in recent years more than any other new material. These composites, or fiber reinforced polymers, offer huge advantages over structural steel reinforced concrete or timber. A few of these advantages are the superior resistance to corrosion, high stiffness to weight and strength to weight ratios, and the ability to control the material's behavior by selecting the orientation of the fibers. The design and field application research on reinforced concrete cap beam-column joints includes analytical investigations using pushover analysis; design of carbon fiber layout, experimental tests and field applications. Several beam column joints have been tested recently with design variables as the type of composite system, fiber orientation and the width of carbon fiber sheets. The surface preparation has been found to be critical for the bond between concrete and composite material, which is the most important factor in joint shear strengthening. The final goal of this thesis is to develop design aids for retrofitting reinforced concrete beam column joints. Two bridge bents were tested on the Interstate-15 corridor. One bent was tested in the as-is condition. Carbon fiber reinforced plastic composite sheets were used to externally reinforce the second bridge bent. By applying the composite, the displacement ductility has been doubled, and the bent overall lateral load capacity has been increased as well. The finite element model (using DRAIN-2DX) was calibrated to model the actual stiffness of the supports. The results were similar to the experimental findings.

  9. Proposed Methodology for Design of Carbon Fiber Reinforced Polymer Spike Anchors into Reinforced Concrete

    Energy Technology Data Exchange (ETDEWEB)

    MacFarlane, Eric Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-26

    The included methodology, calculations, and drawings support design of Carbon Fiber Reinforced Polymer (CFRP) spike anchors for securing U-wrap CFRP onto reinforced concrete Tbeams. This content pertains to an installation in one of Los Alamos National Laboratory’s facilities. The anchors are part of a seismic rehabilitation to the subject facility. The information contained here is for information purposes only. The reader is encouraged to verify all equations, details, and methodology prior to usage in future projects. However, development of the content contained here complied with Los Alamos National Laboratory’s NQA-1 quality assurance program for nuclear structures. Furthermore, the formulations and details came from the referenced published literature. This literature represents the current state of the art for FRP anchor design. Construction personnel tested the subject anchor design to the required demand level demonstrated in the calculation. The testing demonstrated the ability of the anchors noted to carry loads in excess of 15 kips in direct tension. The anchors were not tested to failure in part because of the hazards associated with testing large-capacity tensile systems to failure. The calculation, methodology, and drawing originator was Eric MacFarlane of Los Alamos National Laboratory’s (LANL) Office of Seismic Hazards and Risk Mitigation (OSHRM). The checker for all components was Mike Salmon of the LANL OSHRM. The independent reviewers of all components were Insung Kim and Loring Wyllie of Degenkolb Engineers. Note that Insung Kim contributed to the initial formulations in the calculations that pertained directly to his Doctoral research.

  10. Corrosion of Steels in Steel Reinforced Concrete in Cassava Juice

    Science.gov (United States)

    Oluwadare, G. O.; Agbaje, O.

    The corrosion of two types of construction steels, ST60Mn and RST37-2♦, in a low cyanide concentration environment (cassava juice) and embedded in concrete had been studied. The ST60 Mn was found to be more corrosion resistant in both ordinary water and the cassava juice environment. The cyanide in cassava juice does not attack the steel but it provides an environment of lower pH around the steel in the concrete which leads to breakdown of the passivating film provided by hydroxyl ions from cement. Other factors such as the curing time of the concrete also affect the corrosion rates of the steel in the concrete. The corrosion rate of the steel directly exposed to cassava juice i.e., steel not embedded in concrete is about twice that in concrete. Long exposure of concrete structure to cassava processing effluent might result in deterioration of such structures. Careful attention should therefore be paid to disposal of cassava processing effluents, especially in a country like Nigeria where such processing is now on the increase.

  11. Mitigation of chloride and sulfate based corrosion in reinforced concrete via electrokinetic nanoparticle treatment

    Science.gov (United States)

    Kupwade-Patil, Kunal

    Concrete is a porous material which is susceptible to the migration of highly deleterious species such as chlorides and sulfates. Various external sources, including sea salt spray, direct seawater wetting, deicing salts and chlorides can contaminate reinforced concrete. Chlorides diffuse into the capillary pores of concrete and come into contact with the reinforcement. When chloride concentration at the reinforcement exceeds a threshold level it breaks down the passive oxide layer, leading to chloride induced corrosion. The application of electrokinetics using positively charged nanoparticles for corrosion protection in reinforced concrete structures is an emerging technology. This technique involves the principle of electrophoretic migration of nanoparticles to hinder chloride diffusion in the concrete. The return of chlorides is inhibited by the electrodeposited assembly of the nanoparticles at the reinforcement interface. This work examined the nanoparticle treatment impact on chloride and sulfate induced corrosion in concrete. Electrokinetic Nanoparticle (EN) treatments were conducted on reinforced cylindrical concrete, rectangular ASTM G109 specimens that simulate a bridge deck and full scale beam specimens. EN treatment to mitigate external sulfate attack in concrete was performed on cylindrical concrete specimens. Corrosion results indicated lower corrosion potentials and rates as compared to the untreated specimens. Scanning electron microscopy (SEM) showed a dense microstructure within the EN treated specimens. Chemical analysis (Raman spectroscopy, X ray-diffraction, and Fourier transform infrared spectroscopy FTIR) showed the presence of strength enhancing phases such as calcium aluminate hydrate (C-A-H) and increased amounts of calcium silicate hydrate (C-S-H) within the EN treated specimens. Strength and porosity results showed an increase in strength and a reduction in porosity among the EN treated specimens. EN treatment acted as a protective

  12. Healing Effectiveness of Cracks Rehabilitation in Reinforced Concrete Using Electrodeposition Method

    Institute of Scientific and Technical Information of China (English)

    JIANG Zhengwu; XING Feng; SUN Zhenping; WANG Peiming

    2008-01-01

    An electrodeposition method and its experimental device for rehabilitation of cracks in reinforced concrete were proposed.Porous concrete is proposed to simulate cracked concrete,and mass increment,permeation coefficient and sound velocity of ultrasonic wave were used to be evaluating indicators of healing effectiveness of crack rehabilitation in this method.Effect of currency density,concentration of electrolyte solution on healing effectiveness of porous reinforced concretes with different total void ratio was studied.The experimental results indicate that the simulation of porous concrete for cracks can reflect the healing effectiveness of electrodeposition method effectively.Total void ratio of porous concrete has little effect on healing effectiveness of electrodeposition at early ages.The higher the currency density or concentration of electrolyte solution is,the higher the electrodeposition rate and sound velocity in porous concrete are,and the lower the permeation coefficient of porous concrete will be.Mg(OH)2 crystals produced in high current density are large,thin sheet-shaped and arranged loosely.

  13. Behavior of Reinforced Hybrid Concrete Corbel-Column Connection with Vertical Construction Joint

    Directory of Open Access Journals (Sweden)

    Ammar Yasir Ali

    2017-03-01

    Full Text Available In this paper, shear behavior of reinforced hybrid concrete connection of corbel-column is experimentally investigated. Nine homogenous and hybrid concrete corbel-column connections subjected to vertical applied loads were constructed and tested within two test groups (A, B. The experimental program included the effect of several variables such as type of hybrid concrete;high strength concrete (HSC or steel fiber reinforced concrete (SFRC, monolithic casting of hybrid concrete connection, and presence of construction joint at the interface of corbel-column. Experimental results showed significant effects of concrete hybridization on the structural behavior of connection specimens such as: ultimate strength, cracking loads, cracking patterns, and failure modes. Hybridization process in group (A included hybrid connection of corbel-column with HSC or SFRC corbel instated of NSC. This process led to increase the capacity of connection by (26%, 38% and shear cracking loads by (20%, 120% respectively. Moreover, connections of hybrid concrete corbels cast monolithically improved the shear capacity of corbels by (19%, 42% for HSC or SFRC respectively. In group (B, presence of construction joint at connection region reduced the shear capacity of connectionsby (10% to 22% and cracking loads by (23%-62% compared with connections cast monolithically.

  14. Experimental Study On The Flexural And Shear Analysis Of Concrete Beams Rein Forced With Glass Fiber -Reinforced (Gfrp Bars

    Directory of Open Access Journals (Sweden)

    Edgaras Atutis

    2013-12-01

    Full Text Available The paper analyzes experimental studies examining the flexuraland shear analysis of the beams reinforced with GFRP bars. Atesting program consisted of two beams reinforced with longitudinalprestressed GFRP tendons, two beams reinforced withlongitudinal GFRP bars and two beams reinforced with longitudinalsteel reinforcement and shear reinforcement of GFRP bars.The experimental flexural and shear strength of concrete beamswere compared with theoretical strength calculated according toa number of design recommendations, and the significance ofprestressing for deflection and cracking was analyzed.

  15. Structural Precast Concrete Handbook

    DEFF Research Database (Denmark)

    Kjærbye, Per Oluf H

    Structural concept for precast concrete systems. Design og precast reinforced concrete components. Design of precast concrete connections. Illustrations on design of precast concrete buildings. Precast concrete assembly....

  16. Fem Modelling and Analysis of Reinforced Concrete Section with Light Weight Blocks Infill

    Directory of Open Access Journals (Sweden)

    T. Subramani

    2014-06-01

    Full Text Available In an attempt to reduce the self weight of reinforced concrete structures, a new development of lightweight sandwich reinforced concrete (LSRC section has been proposed as an alternative option to solid section. LSRC section is a reinforced concrete section which contains lightweight blocks as infill material. An experimental investigation into the strength of LSRC beams has shown promising results under flexural tests. To ensure the serviceability of LSRC members under service load, it is necessary to accurately predict the cracking and deflection of this section. This paper will focus on analysing the behaviour of the tested beam specimens after cracking occurs. ANSYS 12.1 was employed to study the crack propagation of LSRC beams under bending. The numerical model shows the crack in the area of AAC blocks which associates with the brittle failure of LSRC beams. The crack propagation of the beams analysed by ANSYS agrees well with the results from the experimental investigation.

  17. Corrosion and mechanical performance of reinforced mortar and concrete made with MSWI bottom ash

    Directory of Open Access Journals (Sweden)

    Rita Ávila

    2017-07-01

    Full Text Available Electrochemical monitoring was performed to evaluate the influence of municipal solid waste incineration residues (MSWI made concrete, on reinforcement corrosion, using four different steel reinforce-ments grades, traditional carbon steel B-500-SD and three stainless steels, the austenite AISI 304, duplex AISI 2304, and lean-duplex AISI 2001, embedded in mortars manufactured using bottom ash as aggregates from the incineration of municipal solid waste (MSW, in partial and total substitution of natural aggregate. In addition, it has been studied the mechanical behaviour of the mortar and concrete matrix in the presence of MSWI aggre-gates. The use of MSWI bottom ash as an aggregate, results in a notable improvement of the resistance charac-teristics of conventional mortar and concrete, made out only of natural aggregate. Moreover, electrochemical measures show that the steels remain in passive state throughout all the exposure period (3 years.

  18. Bond slip model in cylindrical reinforced concrete elements confined with stirrups

    Science.gov (United States)

    Coccia, Simona; Di Maggio, Erica; Rinaldi, Zila

    2015-12-01

    An analytical model able to evaluate the bond-slip law of confined reinforced concrete elements is developed and presented in this paper. The model is based on the studies developed by Tepfers and by den Uijl and Bigaj on the thick-walled cylinder model and extended to the case of the presence of transverse reinforcement. The bond strength and the considered failure modes (splitting or pull-out failure) are expressed as a function of the geometrical (concrete cover and transverse reinforcement) and mechanical (concrete strength) parameters of the element. The application of the proposed methodology allows to forecast the failure mode, and equations for the bond-slip law are finally proposed for a range of steel strain lower than the yielding one.

  19. Evolution of the health of concrete structures by electrically conductive GFRP (glass fiber reinforced plastic) composites

    Science.gov (United States)

    Shin, Soon-Gi

    2002-02-01

    The function and performance of self-diagnostic composites embedded in concrete blocks and piles were investigated by bending tests and electrical resistance measurement. Carbon powder (CP) and carbon fiber (CF) were introduced into glass fiber reinforced plastic (GFRP) composites to provide electrical conductivity. The CPGFRP composite displays generally good performance in various bending tests of concrete block and piles compared to the CFGFRP composite. The electrical resistance of the CPGFRP composite increases remarkably at small strains in response to microcrack formation at about 200 μm strain, and can be used to detect smaller deformations before crack formation. The CPGFRP composite shows continuous change in resistance up to a large strain level just before the final fracture for concrete structures reinforced by steel bars. It is concluded that self-diagnostic composites can be used to predict damage and fracture in concrete blocks and piles.

  20. Analysis of the Behaviour of Composite Steel and Steel Fiber Reinforced Concrete Slabs

    Directory of Open Access Journals (Sweden)

    Mindaugas Petkevičius

    2011-04-01

    Full Text Available There was a pending influence of steel fiber on the strength and stiffness of composite steel–concrete slabs under statical short–time load. Steel profiled sheeting and steel fiber reinforced concrete were used for specimens. Four composite slabs were made. Experimental investigations into the behaviour and influence of steel fiber reinforced concrete in composite slabs were conducted. Transverse, longitudinal, shear deformation and deflection of the slab were measured. The results indicated that the use of steel fiber in composite slabs was effective: strength was 20–24 % higher and the meanings of deflections under the action of the bending moment were 0,6MR (where MR is the bending moment at failure of the slabs and were 16–18 % lower for slabs with usual concrete. Article in Lithuanian

  1. PS buildings : reinforced concrete structure for shielding "bridge" pillar

    CERN Document Server

    CERN PhotoLab

    1956-01-01

    The PS ring traverses the region between the experimental halls South and North (buildings Nos 150 and 151) under massive bridge-shaped concrete beams. This pillar stands at the S-W end of the structure.

  2. Determination of concrete cover thickness in a reinforced concrete pillar by observation of the scattered electromagnetic field

    Science.gov (United States)

    Di Gregorio, Pietro Paolo; Frezza, Fabrizio; Mangini, Fabio; Pajewski, Lara

    2017-04-01

    The electromagnetic scattered field by a reinforced concrete structure is calculated by means of frequency-domain numerical simulations and by making use of the scattered-field formulation. The concrete pillar, used as supporting architectural element, is modelled as a parallelepiped shell made of concrete material inside which are present steel bars. In order to make the model simpler, the steel bars are supposed running parallel to the air-pillar interface. To excite the model, a linearly-polarized plane wave impinging normally with respect to the pillars surface, is adopted. We consider two different polarizations in order to determine the most useful in terms of scattered-field sensitivity. Moreover, a preliminary frequency sweep allows us to choose the most suitable operating frequency depending on the dimensions of the pillar cross-section, the steel bars cross-section and the concrete cover. All the three components of the scattered field are monitored along a line just above the interface air-pillar. The electromagnetic properties of the materials employed in this study are present in the literature and, since a frequency-domain technique is adopted, no further approximation is needed. The results obtained for different values of the concrete cover are compared, with the goal of determining the scattered field dependence on the concrete cover thickness. Considering different concrete cover thicknesses, we want to provide an electromagnetic method to obtain this useful parameter by observation of the scattered electromagnetic field. One of the practical applications of this study in the field of Civil Engineering may be the use of ground penetrating radar (GPR) techniques to monitor the thickness of the concrete that separates the metal bars embedded in the pillar from the outer surface. A correct distance is useful because the concrete cover serves as a protection against external agents avoiding corrosion of the bars that might prejudice the reinforced

  3. Experimental study of bond-slip performance of corroded reinforced concrete under cyclic loading

    Directory of Open Access Journals (Sweden)

    Haijun Zhou

    2015-03-01

    Full Text Available Reinforced concrete structures exposed to marine environment often sustain high levels of chloride-induced reinforcement corrosion, which causes reinforcement corrosion and resulting in degraded performance under cyclic service loading. This article studied the dynamic bond performance between corroded reinforcing and concrete under force controlled loading. Tests were carried out to evaluate the cyclic bond-slip degradation with different reinforcement corrosion levels. A series of 30 specimens with various corrosion levels of rebar and stirrup were made. The specimen was cast as concrete cube with the dimension of 200 mm, and a steel rebar was centrally embedded with two stirrups around. The embedded steel rebar and stirrups were corroded using an electrochemical accelerated corrosion technique. The corrosion crack opening width and length were recorded after completion of artificial corrosion. Then, cyclic loading test was carried out; three different force levels of 24, 36, and 48 kN were adopted. The effects of reinforcement corrosion rate on crack opening, maximum slip, energy dissipation, and unloading stiffness were discussed in detail. It was found that both reinforcement corrosion rate and crack opening would have significant effects on cyclic bond performance. Further studies are urgently needed to quantify these effects to the cyclic bond performance.

  4. Stay-in-Place Formwork of TRC Designed as Shear Reinforcement for Concrete Beams

    Directory of Open Access Journals (Sweden)

    S. Verbruggen

    2013-01-01

    Full Text Available In order to reduce on-site building time, the construction industry shows an increasing interest in stay-in-place formwork with a reinforcement function after concrete hardening, such as CFRP formwork confinement for columns. The current combined systems however do not answer the demand of the building industry for a material system that is both lightweight and fire safe. High performance textile reinforced cement (TRC composites can address this need. They can be particularly interesting for the shear reinforcement of concrete beams. This paper describes a preliminary analysis and feasibility study on structural stay-in-place formwork made of TRC. Comparative bending experiments demonstrate that a fully steel reinforced beam and an equivalent beam with shear reinforcement in TRC formwork show similar yielding behaviour, indicating that the TRC shear reinforcement system actually works. Moreover, the cracking moment of the concrete was more or less doubled, resulting in a much lower deflection in serviceability limit state than calculated. Digital image correlation measurements show that the latter is due to the crack bridging capacity of the external TRC shear reinforcement.

  5. A state of the art review on reinforced concrete beams with openings retrofitted with FRP

    Science.gov (United States)

    Osman, Bashir H.; Wu, Erjun; Ji, Bohai; S Abdelgader, Abdeldime M.

    2016-09-01

    The use of externally bonded fiber reinforced polymer (FRP) sheets, strips or steel plates is a modern and convenient way for strengthening of reinforced concrete (RC) beams. Several researches have been carried out on reinforced concrete beams with web openings that strengthened using fiber reinforced polymer composite. Majority of researches focused on shear strengthening compared with flexural strengthening, while others studied the effect of openings on shear and flexural separately with various loading. This paper investigates the impact of more than sixty articles on opening reinforced concrete beams with and without strengthening by fiber reinforcement polymers FRP. Moreover, important practical issues, which are contributed in shear strengthening of beams with different strengthening techniques, such as steel plate and FRP laminate, and detailed with various design approaches are discussed. Furthermore, a simple technique of applying fiber reinforced polymer contributed with steel plate for strengthening the RC beams with openings under different load application is concluded. Directions for future research based on the existing gaps of the present works are presented.

  6. Pore pressure development in hybrid fibre-reinforced high strength concrete at elevated temperatures

    OpenAIRE

    Bangi, Mugume Rodgers; HORIGUCHI, Takashi

    2011-01-01

    The present experimental work investigates the build-up of pore pressure at different depths of High Strength Concrete (HSC) and Hybrid-Fibre-Reinforced High Strength Concrete (HFRHSC) when exposed to different heating rates. First, the effect of the measurement technique on maximum pore pressures measured was evaluated. The pressure measurement technique which utilized a sintered metal and silicon oil was found to be the most effective technique for pore pressure measurement. Pore pressure m...

  7. Modelling the influence of age of steel fibre reinforced self : compacting concrete on its compressive behaviour

    OpenAIRE

    Cunha, Vitor M. C. F.; Barros, Joaquim A.O.; Sena-Cruz, José

    2008-01-01

    Documento submetido para revisão pelos pares. A publicar na revista "Materials and Structures Journal". ISSN 1359-5997. Steel fibre reinforced self-compacting concrete (SFRSCC) can combine the benefits of self-consolidating concrete technology with those derived from adding steel fibres to quasi-brittle cement based materials. In a recent applied research project joining pre-casting industry, private and public research institutions, a method was developed to design cost-...

  8. Shear strength of non-shear reinforced concrete elements

    DEFF Research Database (Denmark)

    Hoang, Cao linh

    1997-01-01

    The paper deals with the plastic shear strength of non shear reinforced T-beams.The influence of an un-reinforced flange on the shear capacity is investigated by considering a failure mechanism involving crack sliding in the web and a kind of membrane action over an effective width of the flange...

  9. Integrated modelling of corrosion-induced deterioration in rein-forced concrete structures

    DEFF Research Database (Denmark)

    Michel, Alexander; Geiker, M.R.; Stang, Henrik

    2013-01-01

    An integrated finite element based modelling approach is presented, which allows for fully coupled simulation of reinforcement corrosion and corrosion-induced concrete damage. While a finite element method (FEM) based corrosion model was used to describe electrochemical processes at the reinforce...... use of the modelling approach, a numerical example is presented which illustrates full coupling of formation of corrosion cells, propagation of corrosion, and subsequent development of corrosion-induced concrete damage.......An integrated finite element based modelling approach is presented, which allows for fully coupled simulation of reinforcement corrosion and corrosion-induced concrete damage. While a finite element method (FEM) based corrosion model was used to describe electrochemical processes...... at the reinforcement surface, a FEM based me-chanical model was used to simulate corrosion-induced concrete damage. Both FEM models were fully coupled, i.e. information, such as corrosion current density, dam-age state of concrete cover, etc., were constantly exchanged between the models. To demonstrate the potential...

  10. Experimental Study, Simulation and Model Predictions of Recycled PET Strip-Reinforced Concrete Flexion Members

    Directory of Open Access Journals (Sweden)

    F.J. Baldenebro-Lopez

    2014-07-01

    Full Text Available This study presents results from a theoretical-experimental program of beams partially pre-stressed made with continuous recycled PET strip-reinforced concrete (plain concrete strength of 20 MPa. These studies mainly attempted to determine the stripinfluence in altering the flexural strength at first and final crack. Also the load-deflection, ductility, energy absorption capacity of the beams are observed and the studies can be used in predicting the flexural behavior of longitudinally reinforced concrete. The model theory assumes that concrete has a tensile load capacity different from zero, characterized by a uniaxial tensile stress-strain diagram. The need for non-linear geometric and the material models imply the use of numerical methods such as the finite element method; so that, a finite element analysis of reinforced concrete beam with strips-reinforced plastic is performed. The obtained results were compared with computer analysis and experimental data to corroborate the validity of the suggested method, showing that the theory also predicts correctly the post-cracking creep deformation.

  11. Influence of Freeze-Thaw Damage on the Steel Corrosion and Bond-Slip Behavior in the Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Fangzhi Zhu

    2016-01-01

    Full Text Available This paper mainly studies the behavior of steel corrosion in various reinforced concrete under freeze-thaw environment. The influence of thickness of concrete cover is also discussed. Additionally, the bond-slip behavior of the reinforced concrete after suffering the freeze-thaw damage and steel corrosion has also be presented. The results show that the freeze-thaw damage aggravates the steel corrosion in concrete, and the results become more obvious in the concrete after suffering serious freeze-thaw damage. Compared with the ordinary concrete, both air entrained concrete and waterproofing concrete possess better resistance to steel corrosion under the same freeze-thaw environment. Moreover, increasing the thicknesses of concrete cover is also an effective method of improving the resistance to steel corrosion. The bond-slip behavior of reinforced concrete with corroded steel decreases with the increase of freeze-thaw damage, especially for the concrete that suffered high freeze-thaw cycles. Moreover, there exists a good correlation between the parameters of bond-slip and freeze-thaw cycles. The steel corrosion and bond-slip behavior of reinforced concrete should be considered serious under freeze-thaw cycles environment, which significantly impact the durability and safety of concrete structure.

  12. Selected Bibliography on Fiber-Reinforced Cement and Concrete. Supplement Number 4.

    Science.gov (United States)

    1982-08-01

    Building Industry," L’Industria Italiana del Cemento , Vol 50, No. 12, Dec 1980, pp 1135-1144. 19. Bartos, P., "Pullout Failure of Fibres Embedded in Cement...Vol 43, No. 11, Nov 1977, pp 561-564. 21. Bassan, M., "Model of Behavior of Fiber-Reinforced Concretes Under Impact Stresses," il Cemento , Vol 74, No...Pastes," il Cemento , Vol 75, No. 3, Jul-Sep 1978, pp 277-284. 210. Mills, R. H., "Age-Embrittlement of Glass-Reinforced Concrete Containing Blastfurance

  13. Behavior of FRP Bars-Reinforced Concrete Slabs under Temperature and Sustained Load Effects

    Directory of Open Access Journals (Sweden)

    Hizia Bellakehal

    2014-03-01

    Full Text Available The large temperature variation has a harmful effect on concrete structures reinforced with fiber reinforced polymer (FRP bars. This is due to the significant difference between transverse coefficient of thermal expansion of these bars and that of the hardened concrete. This difference generates a radial pressure at the FRP bar/concrete interface, and may cause splitting cracks within concrete. This paper presents results of an experimental and analytical study carried out on FRP-reinforced concrete slabs subjected, simultaneously, to thermal and mechanical loads. The analytical model based on the theory of linear elasticity consists to evaluate combined effects of thermal and mechanical loads on the transverse expansion of FRP bars. Parameters studied in this investigation are the concrete cover thickness, FRP bar diameter, and the temperature variation. The thermal cycles were varied from −30 to +60 °C. Comparisons between analytical and experimental results show that transverse strains predicted from the proposed model are in good correlation with experimental results.

  14. Covercrete with hybrid functions - A novel approach to durable reinforced concrete structures

    Energy Technology Data Exchange (ETDEWEB)

    Tang, L.; Zhang, E.Q. [Chalmers University of Technology, SE-412 96 Gothenburg (Sweden); Fu, Y. [KTH Royal Institute of Technology, SE-106 91 Stockholm (Sweden); Schouenborg, B.; Lindqvist, J.E. [CBI Swedish Cement and Concrete Research Institute, c/o SP, Box 857, SE-501 15 Boraas (Sweden)

    2012-12-15

    Due to the corrosion of steel in reinforced concrete structures, the concrete with low water-cement ratio (w/c), high cement content, and large cover thickness is conventionally used for prolonging the passivation period of steel. Obviously, this conventional approach to durable concrete structures is at the sacrifice of more CO{sub 2} emission and natural resources through consuming higher amount of cement and more constituent materials, which is against sustainability. By placing an economically affordable conductive mesh made of carbon fiber or conductive polymer fiber in the near surface zone of concrete acting as anode we can build up a cathodic prevention system with intermittent low current density supplied by, e.g., the solar cells. In such a way, the aggressive negative ions such as Cl{sup -}, CO{sub 3}{sup 2-}, and SO{sub 4}{sup 2-} can be stopped near the cathodic (steel) zone. Thus the reinforcement steel is prevented from corrosion even in the concrete with relatively high w/c and small cover thickness. This conductive mesh functions not only as electrode, but also as surface reinforcement to prevent concrete surface from cracking. Therefore, this new type of covercrete has hybrid functions. This paper presents the theoretical analysis of feasibility of this approach and discusses the potential durability problems and possible solutions to the potential problems. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Seismic Material Properties of Reinforced Concrete and Steel Casing Composite Concrete in Elevated Pile-Group Foundation

    Directory of Open Access Journals (Sweden)

    Zhou Mi

    2015-09-01

    Full Text Available The paper focuses on the material mechanics properties of reinforced concrete and steel casing composite concrete under pseudo-static loads and their application in structure. Although elevated pile-group foundation is widely used in bridge, port and ocean engineering, the seismic performance of this type of foundation still need further study. Four scale-specimens of the elevated pile-group foundation were manufactured by these two kinds of concrete and seismic performance characteristic of each specimen were compared. Meanwhile, the special soil box was designed and built to consider soil-pile-superstructure interaction. According to the test result, the peak strength of strengthening specimens is about 1.77 times of the others and the ultimate displacement is 1.66 times of the RC specimens. Additionally, the dissipated hysteric energy capability of strengthening specimens is more than 2.15 times of the others as the equivalent viscous damping ratio is reduced by 50%. The pinching effect of first two specimens is more obvious than latter two specimens and the hysteretic loops of reinforced specimens are more plumpness. The pseudo-static tests also provided the data to quantitatively assessment the positive effect of steel casing composite concrete in aseismatic design of bridge.

  16. Experimental and Empirical Time to Corrosion of Reinforced Concrete Structures under Different Curing Conditions

    Directory of Open Access Journals (Sweden)

    Ahmed A. Abouhussien

    2014-01-01

    Full Text Available Reinforced concrete structures, especially those in marine environments, are commonly subjected to high concentrations of chlorides, which eventually leads to corrosion of the embedded reinforcing steel. The total time to corrosion of such structures may be divided into three stages: corrosion initiation, cracking, and damage periods. This paper evaluates, both empirically and experimentally, the expected time to corrosion of reinforced concrete structures. The tested reinforced concrete samples were subjected to ten alternative curing techniques, including hot, cold, and normal temperatures, prior to testing. The corrosion initiation, cracking, and damage periods in this investigation were experimentally monitored by an accelerated corrosion test performed on reinforced concrete samples. Alternatively, the corrosion initiation time for counterpart samples was empirically predicted using Fick’s second law of diffusion for comparison. The results showed that the corrosion initiation periods obtained experimentally were comparable to those obtained empirically. The corrosion initiation was found to occur at the first jump of the current measurement in the accelerated corrosion test which matched the half-cell potential reading of around −350 mV.

  17. Effect of the reinforcement bar arrangement on the efficiency of electrochemical chloride removal technique applied to reinforced concrete structures

    Energy Technology Data Exchange (ETDEWEB)

    Garces, P. [Dpto. Ing. de la Construccion, Obras Publicas e Infraestructura Urbana, Universidad de Alicante. Apdo. 99, E-03080 Alicante (Spain)]. E-mail: pedro.garces@ua.es; Sanchez de Rojas, M.J. [Dpto. Ing. de la Construccion, Obras Publicas e Infraestructura Urbana, Universidad de Alicante. Apdo. 99, E-03080 Alicante (Spain); Climent, M.A. [Dpto. Ing. de la Construccion, Obras Publicas e Infraestructura Urbana, Universidad de Alicante. Apdo. 99, E-03080 Alicante (Spain)

    2006-03-15

    This paper reports on the research done to find out the effect that different bar arrangements may have on the efficiency of the electrochemical chloride removal (ECR) technique when applied to a reinforced concrete structural member. Five different types of bar arrangements were considered, corresponding to typical structural members such as columns (with single and double bar reinforcing), slabs, beams and footings. ECR was applied in several steps. We observe that the extraction efficiency depends on the reinforcing bar arrangement. A uniform layer set-up favours chloride extraction. Electrochemical techniques were also used to estimate the reinforcing bar corrosion states, as well as measure the corrosion potential, and instant corrosion rate based on the polarization resistance technique. After ECR treatment, a reduction in the corrosion levels is observed falling short of the depassivation threshold.

  18. An Experimental Study of a Midbroken 2-Bay 6-Storey Reinforced Concrete Frame subject to Earthquakes

    DEFF Research Database (Denmark)

    Skjærbæk, P. S.; Taskin, B.; Kirkegaard, Poul Henning;

    1997-01-01

    A 2-bay, 6-storey model test reinforced concrete frame (scale 1:5) subjected to sequential earthquakes of increasing magnitude is considered in this paper. The frame was designed with a weak storey, in which the columns are weakened by using thinner and weaker reinforcement bars. The aim of the w......A 2-bay, 6-storey model test reinforced concrete frame (scale 1:5) subjected to sequential earthquakes of increasing magnitude is considered in this paper. The frame was designed with a weak storey, in which the columns are weakened by using thinner and weaker reinforcement bars. The aim...... of the work is to study global response to a damaging strong motion earthquake event of such buildings. Special emphasis is put on examining to what extent damage in the weak storey can be identified from global response measurements during an earthquake where the structure survives, and what level...

  19. Flow simulation of fiber reinforced self compacting concrete using Lattice Boltzmann method

    DEFF Research Database (Denmark)

    Svec, Oldrich; Skocek, Jan; Stang, Henrik

    2011-01-01

    Self compacting concrete (SCC) is a promising material in the civil engineering industry. One of the benefits of the SCC is a fast and simplified casting followed by decreased labor costs. The SCC as any other type of concrete has a significantly lower tensile and shear strength in comparison to ....... A relatively new group of models - Lattice Boltzmann Modeling (LBM) - is presented in this paper. The conventional LBM is modified to include fiber and particle suspensions and non-Newtonian rheology and is used to model the fiber reinforced self compacting concrete flow....

  20. Active tendon control of reinforced concrete frame structures subjected to near-fault effects

    Science.gov (United States)

    Nigdeli, Sinan Melih; Boduroǧlu, M. Hasan

    2013-10-01

    A reinforced concrete (RC) frame structure was controlled with active tendons under the excitation of near-fault ground motions. Proportional Integral Derivative (PID) type controllers were used and the controller was tuned by using a numerical algorithm. In order to prevent brittle fracture of the structure, the aim of the control is to reduce maximum base shear force. The RC structure was investigated for different characteristic strengths of concrete and the approach is applicable for the structure with 14 MPa concrete strength or higher.

  1. Quantifying movements of corrosion products in reinforced concrete using x-ray attenuation measurements

    DEFF Research Database (Denmark)

    Pease, Bradley Justin; Michel, Alexander; Stang, Henrik

    2011-01-01

    of corrosion products move into the concrete without generating tensile stresses and cracks in the concrete. Typically, corrosion products are thought to occupy pores, interfacial defects, and/or air voids located near the concrete-steel interface and stresses develop only after filling of these pores. Further....... X-ray attenuation measurements are also capable of detecting cracks. Therefore, this approach provides a direct measurement of the amount and location of reinforcement corrosion products required to induce cracking. Results of a parametric investigation on the impact of water-to-cement ratio (0...

  2. Flexural Behaviour Of Reinforced Concrete Beams Containing Expanded Glass As Lightweight Aggregates

    Science.gov (United States)

    Khatib, Jamal; Jefimiuk, Adrian; Khatib, Sammy

    2015-12-01

    The flexural properties of reinforced concrete beams containing expanded glass as a partial fine aggregate (sand) replacement are investigated. Four concrete mixes were employed to conduct this study. The fine aggregate was replaced with 0%, 25%, 50% and 100% (by volume) expanded glass. The results suggest that the incorporation of 50% expanded glass increased the workability of the concrete. The compressive strength was decreasing linearly with the increasing amount of expanded glass. The ductility of the concrete beam significantly improved with the incorporation of the expanded glass. However, the load-carrying capacity of the beam and load at which the first crack occurs was reduced. It was concluded that the inclusion of expanded glass in structural concrete applications is feasible.

  3. Post-cracking Behaviour and Fracture Energy of Synthetic Fibre Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Marta KOSIOR-KAZBERUK

    2016-11-01

    Full Text Available The paper reports the results of experimental programme focused on the effect of various synthetic fibres on fracture properties and ductility of concrete. The fracture energy was assessed on beams with initial notches in three-point bend test. The incorporation of synthetic fibres had a slight effect on mechanical properties of concrete but, at the same time, it had a significant influence on the fracture energy by modification of post-cracking behaviour of concrete. It was found that the modern synthetic fibres might be able to impart significant toughness and ductility to concrete. However, the beneficial effect of fibres depends on their length and flexibility. The analysis of load-deflection curves obtained made it possible to fit the simple function, describing the post-peak behaviour of fibre reinforced concrete, which can be useful for the calculation of GF value.DOI: http://dx.doi.org/10.5755/j01.ms.22.4.13246

  4. Predicting the shear–flexural strength of slender reinforced concrete T and I shaped beams

    OpenAIRE

    Cladera Bohigas, Antoni; Marí Bernat, Antonio Ricardo; Ribas González, Carlos Rodrigo; Bairán García, Jesús Miguel; Oller Ibars, Eva

    2015-01-01

    A mechanical model previously developed by the authors for the prediction of the shear flexural strength of slender reinforced concrete beams with rectangular cross-section with or without stirrups has been extended to beams with T and I cross-sections. The effects of the section shape on each shear transfer action have been identified and incorporated into the corresponding equations. General expressions for strength verification and transverse reinforcement design have been derived. The con...

  5. Experimental Investigation and Analytical Modeling of Prefabricated Reinforced Concrete Sandwich Panels

    OpenAIRE

    BOURNAS DIONYSIOS; TORRISI Gonzalo; CRISAFULLI Francisco; Pavese, Alberto

    2012-01-01

    The behavior of prefabricated reinforced concrete sandwich panels (RCSPs) was investigated experimentally and analytically in this study. Initially, tests were carried out on single full-scale RCSPs with or without openings, reproducing the behavior of lateral resisting cantilever and fixed-end walls. The performance and failure mode of all panels tested revealed coupling between the flexure and shear response. However due to their well-detailed reinforcement, all panels exhibited a relativel...

  6. Possibility of improvement of potentiodynamic method for monitoring corrosion rate of steel reinforcement in concrete

    Indian Academy of Sciences (India)

    V Živica

    2001-10-01

    Quantitative data on corroding steel reinforcement in reinforced concrete structures are undoubtedly very useful for evaluation of their service life and timely repairs. The method of electrode potential measurement is a convenient and simple test for this purpose, but it provides no quantitative data on corrosion rate and only information regarding active or passive state of steel reinforcement can be obtained. We show here the possibility of obtaining quantitative data on degree of corrosion of steel reinforcement by a potentiodynamic method. The developed method is based on experimentally estimated mathematical relation between the results of potentiodynamic method and degree of corrosion of steel reinforcement. It is possible to calculate the degree of corrosion of steel reinforcement using this mathematical relation and the measured values of current density by the potentiodynamic method.

  7. Corrosion Behavior of Steel Reinforcement in Concrete with Recycled Aggregates, Fly Ash and Spent Cracking Catalyst

    Directory of Open Access Journals (Sweden)

    Hebé Gurdián

    2014-04-01

    Full Text Available The main strategy to reduce the environmental impact of the concrete industry is to reuse the waste materials. This research has considered the combination of cement replacement by industrial by-products, and natural coarse aggregate substitution by recycled aggregate. The aim is to evaluate the behavior of concretes with a reduced impact on the environment by replacing a 50% of cement by industrial by-products (15% of spent fluid catalytic cracking catalyst and 35% of fly ash and a 100% of natural coarse aggregate by recycled aggregate. The concretes prepared according to these considerations have been tested in terms of mechanical strengths and the protection offered against steel reinforcement corrosion under carbonation attack and chloride-contaminated environments. The proposed concrete combinations reduced the mechanical performance of concretes in terms of elastic modulus, compressive strength, and flexural strength. In addition, an increase in open porosity due to the presence of recycled aggregate was observed, which is coherent with the changes observed in mechanical tests. Regarding corrosion tests, no significant differences were observed in the case of the resistance of these types of concretes under a natural chloride attack. In the case of carbonation attack, although all concretes did not stand the highly aggressive conditions, those concretes with cement replacement behaved worse than Portland cement concretes.

  8. Experimental investigation of axially loaded steel fiber reinforced high strength concrete-filled steel tube columns

    Institute of Scientific and Technical Information of China (English)

    卢亦焱; 李娜; 李杉; 梁鸿骏

    2015-01-01

    An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of steel tube and the steel fiber volume fraction on the ultimate strength and the ductility. The experimental results indicate that the addition of steel fibers in concrete can significantly improve the ductility and the energy dissipation capacity of the concrete-filled steel tube columns and delay the local buckling of the steel tube, but has no obvious effect on the failure mode. It has also been found that the addition of steel fibers is a more effective method than using thicker steel tube in enhancing the ductility, and more advantageous in the case of higher strength concrete. An analytical model to estimate the load capacity is proposed for steel tube columns filled with both plain concrete and steel fiber reinforced concrete. The predicted results are in good agreement with the experimental ones obtained in this work and literatures.

  9. The Vibration Based Fatigue Damage Assessment of Steel and Steel Fiber Reinforced Concrete (SFRC Composite Girder

    Directory of Open Access Journals (Sweden)

    Xu Chen

    2015-01-01

    Full Text Available The steel-concrete composite girder has been usually applied in the bridge and building structures, mostly consisting of concrete slab, steel girder, and shear connector. The current fatigue damage assessment for the composite girder is largely based on the strain values and concrete crack features, which is time consuming and not stable. Hence the vibration-based fatigue damage assessment has been considered in this study. In detail, a steel-steel fiber reinforced concrete (SFRC composite girder was tested. The steel fiber reinforced concrete is usually considered for dealing with the concrete cracks in engineering practice. The composite girder was 3.3m long and 0.45m high. The fatigue load and impact excitation were applied on the specimen sequentially. According to the test results, the concrete crack development and global stiffness degradation during the fatigue test were relatively slow due to the favourable performance of SFRC in tension. But on the other hand, the vibration features varied significantly during the fatigue damage development. Generally, it confirmed the feasibility of executing fatigue damage assessment of composite bridge based on vibration method.

  10. Structural Engineering Properties of Fibre Reinforced Concrete Based On Recycled Glass Fibre Polymer (GFRP

    Directory of Open Access Journals (Sweden)

    Adetiloye A

    2015-04-01

    Full Text Available Glass fibre reinforced plastics (GFRP based on resin recovered from recycling plastic waste has been shown to possess mechanical properties satisfying normative requirements. This paper investigates the flexural behavior of concrete beams reinforced with GFRP produced from resin recovered from recycled plastic wastes. A total of twelve of beams of sizes 150 ×150 ×900mm and 100 × 100 × 500mm reinforced with GFRP made from recycled glass fibre reinforced polymer was tested. The flexural test results yielded lower ultimate load, lower stiffness and larger deflections at the same load when compared with the control steel reinforced beam. However, the ultimate flexural strength of beams, reinforced with GFRP from recycled resin was at least four times higher than that of the control unreinforced beam. This is in agreement, quantitatively and qualitatively, with the trend of these parameters in GFRP reinforced concrete based on virgin resins. The results therefore confirm the applicability for structural uses of GFRP reinforcement made from recycled plastic waste, with the accompanying benefits of wealth creation, value addition and environmental sustainability.

  11. Moment-Curvature Behaviors of Concrete Beams Singly Reinforced by Steel-FRP Composite Bars

    Directory of Open Access Journals (Sweden)

    Zeyang Sun

    2017-01-01

    Full Text Available A steel-fiber-reinforced polymer (FRP composite bar (SFCB is a kind of rebar with inner steel bar wrapped by FRP, which can achieve a better anticorrosion performance than that of ordinary steel bar. The high ultimate strength of FRP can also provide a significant increase in load bearing capacity. Based on the adequate simulation of the load-displacement behaviors of concrete beams reinforced by SFCBs, a parametric analysis of the moment-curvature behaviors of concrete beams that are singly reinforced by SFCB was conducted. The critical reinforcement ratio for differentiating the beam’s failure mode was presented, and the concept of the maximum possible peak curvature (MPPC was proposed. After the ultimate curvature reached MPPC, it decreased with an increase in the postyield stiffness ratio (rsf, and the theoretical calculation method about the curvatures before and after the MPPC was derived. The influence of the reinforcement ratio, effective depth, and FRP ultimate strain on the ultimate point was studied by the dimensionless moment and curvature. By calculating the envelope area under the moment-curvature curve, the energy ductility index can obtain a balance between the bearing capacity and the deformation ability. This paper can provide a reference for the design of concrete beams that are reinforced by SFCB or hybrid steel bar/FRP bar.

  12. Behavior of Concrete Panels Reinforced with Synthetic Fibers, Mild Steel, and GFRP Composites Subjected to Blasts

    Energy Technology Data Exchange (ETDEWEB)

    C. P. Pantelides; T. T. Garfield; W. D. Richins; T. K. Larson; J. E. Blakeley

    2012-03-01

    The paper presents experimental data generated for calibrating finite element models to predict the performance of reinforced concrete panels with a wide range of construction details under blast loading. The specimens were 1.2 m square panels constructed using Normal Weight Concrete (NWC) or Fiber Reinforced Concrete (FRC). FRC consisted of macro-synthetic fibers dispersed in NWC. Five types of panels were tested: NWC panels with steel bars; FRC panels without additional reinforcement; FRC panels with steel bars; NWC panels with glass fiber reinforced polymer (GFRP) bars; and NWC panels reinforced with steel bars and external GFRP laminates on both faces. Each panel type was constructed with three thicknesses: 152 mm, 254 mm, and 356 mm. FRC panels with steel bars had the best performance for new construction. NWC panels reinforced with steel bars and external GFRP laminates on both faces had the best performance for strengthening or rehabilitation of existing structures. The performance of NWC panels with GFRP bars was strongly influenced by the bar spacing. The behavior of the panels is classified in terms of damage using immediate occupancy, life safety, and near collapse performance levels. Preliminary dynamic simulations are compared to the experimental results.

  13. Efficacy of Thermally Conditioned Sisal FRP Composite on the Shear Characteristics of Reinforced Concrete Beams

    Directory of Open Access Journals (Sweden)

    Tara Sen

    2013-01-01

    Full Text Available The development of commercially viable composites based on natural resources for a wide range of applications is on the rise. Efforts include new methods of production and the utilization of natural reinforcements to make biodegradable composites with lignocellulosic fibers, for various engineering applications. In this work, thermal conditioning of woven sisal fibre was carried out, followed by the development of woven sisal fibre reinforced polymer composite system, and its tensile and flexural behaviour was characterized. It was observed that thermal conditioning improved the tensile strength and the flexural strength of the woven sisal fibre composites, which were observed to bear superior values than those in the untreated ones. Then, the efficacy of woven sisal fibre reinforced polymer composite for shear strengthening of reinforced concrete beams was evaluated using two types of techniques: full and strip wrapping techniques. Detailed analysis of the load deflection behaviour and fracture study of reinforced concrete beams strengthened with woven sisal under shearing load were carried out, and it was concluded that woven sisal FRP strengthened beams, underwent very ductile nature of failure, without any delamination or debonding of sisal FRP, and also increased the shear strength and the first crack load of the reinforced concrete beams.

  14. A combined corrosion protection system for reinforced concrete structures using a carbon fibre mesh

    Energy Technology Data Exchange (ETDEWEB)

    Bruns, M.; Raupach, M. [Institut fuer Bauforschung der RWTH Aachen, IBAC, Institute of Building Materials Research of the Technical University of Aachen, Schinkelstrasse 3 Aachen (Germany)

    2004-07-01

    Cathodic Protection (CP) has become a world-wide used method to protect reinforced concrete structures against reinforcement corrosion. Another method to stop or reduce reinforcement corrosion, at least in case of lower chloride contents is the reduction of the water content of the concrete by applying sealing coatings on the concrete surface. At the Institute of Building Materials Research of Aachen University (IBAC) actually a surface protection system is investigated based on the combination of both methods mentioned above. The idea is to protect the reinforcement within the first years after system installation by cathodic protection until the water content of the concrete has decreased to a level due to the surface coating where the corrosion rate of the reinforcement is uncritical and does not lead to any damage. The system investigated, consists of a carbon fibre net embedded in a special mortar layer as impressed current anode for cathodic protection, covered by a 'dense' cement based polymer modified surface coating. In order to investigate the system, it has been installed on a test area on the weathered upper deck of a parking garage in Aachen, Germany. To investigate the effectiveness regarding the reduction of the water content of the concrete the test area was equipped with so called Multiring-Electrodes (MRE) for depth depended measurement of the concrete resistivity. Reference electrodes for potential and depolarization measurements as well a device for automatic measurement of the protection current were installed to investigate the effectiveness of the impressed current cathodic protection. Additionally 3 re bars were embedded into the concrete of the test area using mortar containing 1, 2 or 3 M.-% chloride by weight of cement respectively, to investigate the influence of the chloride content. First results of the MRE-measurements showing already within the first months after system installation a distinct drying of the concrete cover

  15. REINFORCING FIBRES AS PART OF TECHNOLOGY OF CONCRETES

    Directory of Open Access Journals (Sweden)

    Zhukov Aleksey Dmitrievich

    2012-07-01

    It was identified that the basalt fibre consumption rate influences both the strength and the density of products made of cellular concrete. The length of the basalt fibre impacts the strength of products. A nomogram was developed to identify the consumption rate of the basalt fibre driven by the strength of products and the Portland cement consumption rate. The authors also studied the influence of the consumption rate of Portland cement and basalt fibre onto the structural quality ratio of the foamed fibre concrete.

  16. Noninvasive surface measurement of corrosion impedance of reinforcing bar in concrete - part 1: experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jieying; Monteiro, Paulo J.M.; Morrison, H. Frank

    2000-11-01

    The corrosion state of a reinforcing steel bar in concrete can be characterized by the electrical impedance of the interface between the steel bar and the concrete. The experimental part of this study, has shown that changes in the interfacial impedance that are diagnostic of the rate and extent of the corrosion can be measured indirectly with an array of current and voltage electrodes on the concrete surface. The measured impedance, however depends on the electrical resistivity of the concrete, and the depth and diameter of the steel reinforcing bar as well as the interfacial properties. To relate the measured impedance directly to the interfacial properties, a closed-form solution to the governing Poisson's equation was developed and programmed for the potentials from arbitrary, current sources in the vicinity of the reinforcing bar. The solution uses an impedance boundary, condition for the complex impedance at the steel-concrete interface. The response of an arbitrary corrosion state can be simulated in this model by embedding the appropriate complex, frequency-dependent impedance at the interface and computing the voltage/current response that would be measured for an arbitrary placement of electrodes on the concrete surface. To simulate the experimental findings, this paper presents the modeling results by various interfacial impedances but constant concrete resistivity and constant geometry of the steel reinforcing bar This simulation confirms that important parameters of the interfacial impedance controlling corrosion kinetics such as polarization resistance and double layer capacitance are clearly, observed in the measured surface data. [References: 10

  17. Noninvasive surface measurement of corrosion impedance of reinforcing bar in concrete - part 2: forward modeling

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jieying; Monteiro, Paulo J. M.; Morrison, H. Frank

    2002-01-02

    The corrosion state of a reinforcing steel bar in concrete can be characterized by the electrical impedance of the interface between the steel bar and the concrete. The experimental part of this study, has shown that changes in the interfacial impedance that are diagnostic of the rate and extent of the corrosion can be measured indirectly with an array of current and voltage electrodes on the concrete surface. The measured impedance, however depends on the electrical resistivity of the concrete, and the depth and diameter of the steel reinforcing bar as well as the interfacial properties. To relate the measured impedance directly to the interfacial properties, a closed-form solution to the governing Poisson's equation was developed and programmed for the potentials from arbitrary, current sources in the vicinity of the reinforcing bar. The solution uses an impedance boundary, condition for the complex impedance at the steel-concrete interface. The response of an arbitrary corrosion state can be simulated in this model by embedding the appropriate complex, frequency-dependent impedance at the interface and computing the voltage/current response that would be measured for an arbitrary placement of electrodes on the concrete surface. To simulate the experimental findings, this paper presents the modeling results by various interfacial impedances but constant concrete resistivity and constant geometry of the steel reinforcing bar. This simulation confirms that important parameters of the interfacial impedance controlling corrosion kinetics such as polarization resistance and double layer capacitance are clearly, observed in the measured surface data. [References: 10

  18. Life Cycle Cost Analysis of Ready Mix Concrete Plant

    Science.gov (United States)

    Topkar, V. M.; Duggar, A. R.; Kumar, A.; Bonde, P. P.; Girwalkar, R. S.; Gade, S. B.

    2013-11-01

    India, being a developing nation is experiencing major growth in its infrastructural sector. Concrete is the major component in construction. The requirement of good quality of concrete in large quantities can be fulfilled by ready mix concrete batching and mixing plants. The paper presents a technique of applying the value engineering tool life cycle cost analysis to a ready mix concrete plant. This will help an investor or an organization to take investment decisions regarding a ready mix concrete facility. No economic alternatives are compared in this study. A cost breakdown structure is prepared for the ready mix concrete plant. A market survey has been conducted to collect realistic costs for the ready mix concrete facility. The study establishes the cash flow for the ready mix concrete facility helpful in investment and capital generation related decisions. Transit mixers form an important component of the facility and are included in the calculations. A fleet size for transit mixers has been assumed for this purpose. The life cycle cost has been calculated for the system of the ready mix concrete plant and transit mixers.

  19. Finite Element Modeling of Compressive and Splitting Tensile Behavior of Plain Concrete and Steel Fiber Reinforced Concrete Cylinder Specimens

    Directory of Open Access Journals (Sweden)

    Md. Arman Chowdhury

    2016-01-01

    Full Text Available Plain concrete and steel fiber reinforced concrete (SFRC cylinder specimens are modeled in the finite element (FE platform of ANSYS 10.0 and validated with the experimental results and failure patterns. Experimental investigations are conducted to study the increase in compressive and tensile capacity of cylindrical specimens made of stone and brick concrete and SFRC. Satisfactory compressive and tensile capacity improvement is observed by adding steel fibers of 1.5% volumetric ratio. A total of 8 numbers of cylinder specimens are cast and tested in 1000 kN capacity digital universal testing machine (UTM and also modeled in ANSYS. The enhancement of compressive strength and splitting tensile strength of SFRC specimen is achieved up to 17% and 146%, respectively, compared to respective plain concrete specimen. Results gathered from finite element analyses are validated with the experimental test results by identifying as well as optimizing the controlling parameters to make FE models. Modulus of elasticity, Poisson’s ratio, stress-strain behavior, tensile strength, density, and shear transfer coefficients for open and closed cracks are found to be the main governing parameters for successful model of plain concrete and SFRC in FE platform. After proper evaluation and logical optimization of these parameters by extensive analyses, finite element (FE models showed a good correlation with the experimental results.

  20. Feasibility of Using High-Performance Steel Fibre Reinforced Concrete for Simplifying Reinforcement Details of Critical Members

    OpenAIRE

    Seok-Joon Jang; Dae-Hyun Kang; Kyung-Lim Ahn; Wan-Shin Park; Sun-Woong Kim; Hyun-Do Yun

    2015-01-01

    This paper addresses the effects of hooked-end steel fibre contents on the mechanical properties of high-performance concrete (HPC) and investigates the feasibility of utilizing steel fibres to simplify the complicated reinforcement detailing of critical HPC members under high shear stress. Mechanical properties of HPCs with specified compressive strength of 60 and 100 MPa include the flow, air content, compressive strength, and flexural strength. The effectiveness of 1.50% steel fibre conten...

  1. Size effects in plastic hinges of reinforced concrete members

    NARCIS (Netherlands)

    Bigaj-van Vliet, A.J.; Walraven, J.C.

    2002-01-01

    Reasons for size dependence of rotation capacity of plastic hinges are discussed. The increase of ductility with decreasing member size is interpreted from the viewpoint of fracture mechanics of concrete. The results of the introductory test series on simply supported slender beams loaded in three-p

  2. Size Effects in Plastic Hinges of Reinforced Concrete Members

    NARCIS (Netherlands)

    Bigaj, A.; Walraven, J.C.

    2002-01-01

    Reasons for size dependence of rotation capacity of plastic hinges are discussed. The increase of ductility with decreasing member size is interpreted from the viewpoint of fracture mechanics of concrete. The results of the introductory test series on simply supported slender beams loaded in three-p

  3. Flexural Reinforcement of Autoclaved Aerated Concrete (AAC) with ...

    African Journals Online (AJOL)

    Journal of Civil Engineering Research and Practice ... with recent interest in high performance and zero maintenance of civil infrastructures. ... AAC on the other hand is a cellular concrete and it is very light to work with in comparison to the ...

  4. Development of Advanced Constitutive Models for Plain and Reinforced Concrete.

    Science.gov (United States)

    1985-04-08

    appreciation to Dr. D. H. Brownell and ir. R. G. Herrmann , who provided excellent computational support throughout the course of the research...above studies, wniicnh are .11rected towarI nonlinear steel-concrete interaction ef’ecti, severa’ test r~oiems nave been exami ned wich were intended to

  5. Inspection Guide for Reinforced Concrete Vessels. Volume 1. Inspection Guide

    Science.gov (United States)

    1981-10-01

    volume three hours after mixing, and is the separated water reabsorbed after 24 hours7 -18- 4. MATERIALS 4.8 Inserts and Embedments Q~CH LIST INITALS DATE...Aggregates C295 Standard Recommended Practice for Petrographic Examination of Aggregates for Concrete - C309 Standard Specification for I(iqlIid Membrane

  6. Bond slip and crack development in FRC and regular concrete specimens longitudinally reinforced with FRP or steel under tension loading

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor

    2012-01-01

    tensile loading using high definition image analysis in two unique test setups. Two different types of cementitious materials, conventional concrete and highly ductile Engineered Cementitious Composite (ECC), and two types of reinforcement bars, regular steel and Glass Fiber Reinforcement Polymer (GFRP......The governing mechanism in the structural response of reinforced concrete members in tension is the interaction between structural reinforcement and the surrounding concrete matrix. The composite response and the mechanical integrations of reinforced cementitious members were investigated during......), were tested. It was found that the ductile ECC in contrast to regular brittle concrete decreases crack widths significantly which effectively results in decreased bond slip between the reinforcement and surrounding matrix. Furthermore the use of elastic GFRP in comparison to elastic/plastic steel...

  7. Energy Dissipation Capacity of Reinforced Concrete Beams Strengthened with CFRP Strips

    Science.gov (United States)

    Hong, Sungnam; Park, Sun-Kyu

    2016-05-01

    Cyclic loading tests were performed to investigate the energy dissipation capacities of reinforced concrete (RC) beams strengthened with carbon-fiber-reinforced polymer (CFRP) strips. Four RC beams were manufactured and three-point loaded. Responses of the strengthened beams to the cyclic loadings were measured, including deflections at the center of their span and strains of the CFRP strips and reinforcing steel rebars. Based on test results, the energy dissipation capacity of the strengthened beams were evaluated in comparison with that of an unstrengthened control beam.

  8. Dam safety review using non-destructive methods for reinforced concrete structure

    Energy Technology Data Exchange (ETDEWEB)

    Philibert, Alain; Saint-Pierre, Francois; Turcotte, Bernard [Le Groupe S.M. International Inc., Sherbrooke, (Canada)

    2010-07-01

    Dams built at the beginning of the twentieth century include concrete structures that were put in under rehabilitation works. In some cases, the details of the structures are not well documented. In other cases, concrete damage can be hidden under new layers of undamaged material. This requires that the dam safety review in a real investigation gather the information necessary for carrying out the hydraulic and stability studies required by the Dam Safety Act. This paper presented the process of dam safety review using non-destructive methods for reinforced concrete structures. Two reinforced concrete dams built in the 1900's, the Eustic dam on the Coaticook River and the Frontenac dam on the Magog River near Sherbrooke, were evaluated by S.M. International using non-destructive methods such as sonic and ground penetrating radar methods. The studies allowed mapping of concrete damage and provided geometric information on some non visible structure elements that were part of previous reinforcement operations.

  9. Influence of the reinforcement corrosion on the bending moment capacity of reinforced concrete beams: a structural reliability approach

    Directory of Open Access Journals (Sweden)

    E. A. P. Liberati

    Full Text Available Reinforced concrete structures are, certainly, one of the most used types of structure around world. When it is located in non-aggressive environments, it respects, in general, the structural life predicted. Unless the structure be used improperly. However, the durability of these structures is strongly connected to degradation processes whose origin is environmental and/or functional. Among these processes, it is worth to mention those related to corrosion of reinforcements. The reinforcement's corrosion is directly related to the durability and safety of concrete structures. Moreover, the chlorides diffusion is recognized as one of major factors that triggers the corrosion. Therefore, at modelling accurately the chloride diffusion, the corrosion of reinforcements can be better evaluated. Consequently, design criteria can be more realistically proposed in order to assure safety and economy into reinforced concrete structures. Due to the inherent randomness present on chloride diffusion and corrosion, these phenomena can only be properly modelled considering probabilistic approaches. In this paper, the durability of a beam designed using the criteria proposed by ABNT NBR 6118:2003 [1] is assessed using probabilistic approaches. The corrosion time initiation is determined using Fick's diffusion law whereas Faraday's corrosion laws are adopted to model the steel loss. The probability of structural failure is determined using Monte Carlo simulation. The mentioned beam is analysed considering different failure scenarios in order to study the influence of water/cement ratio and environmental aggressiveness on the probability of failure. Based on these results, some remarks are performed considering NBR recommendations and the real probability of failure.

  10. Strength and Toughness of Steel Fibre Reinforced Reactive Powder Concrete Under Blast Loading

    Institute of Scientific and Technical Information of China (English)

    KUZNETSOV Valerian A; REBENTROST Mark; WASCHL John

    2006-01-01

    The blast resistance of structures used in buildings needs to be investigated due to the increased threat of a terrorist attack.The damage done by Composition B or Powergel to steel fibre reinforced reactive powder concrete (SFRPC) panels and ordinary reinforced concrete (RC) panels of equivalent static flexural strength is compared.A 0.5 kg charge was detonated at a distance of 0.1 m from the 1.3 m × 1.0 m × 0.1 m (thick) panels,which were simply supported and spaning 1.3 m.Dynamic displacement measurements,high-speed video recording and visual examination of the panels for spall and breach were undertaken.The SFRPC panels withstood the bare charge blast better than the reinforced ordinary concrete panels.Neither type of panel was breached using a 0.5 kg charge.The RC panel exhibited more spalling when Composition B was used.Under successive Composition B loading conditions,the RC panel was breached.In comparison the SFRPC panel was not breached.Exposure to fragmenting charge loading conditions confirmed these performance differences between the SFRPC panel and the reinforced ordinary concrete panel.

  11. Static and dynamic testing of concrete beams reinforced with fibres and continuous bars

    NARCIS (Netherlands)

    Körmeling, H.A.; Reinhardt, H.W.; Shah, S.P.

    1979-01-01

    The main purpose of the testing program was to get an idea about the influence of steel fibres on the fatigue performance of conventionally reinforced concrete beams. The influence of three types of steel fibres with three various percentages on the failure load, the cycles to failure, the crack wid

  12. Conventional and Pulse Cathodic Protection of Reinforced Concrete: Electrochemical Approach and Microstructural Investigations

    NARCIS (Netherlands)

    Koleva, D.A.; Hu, J.; Van Breugel, K.; De Wit, J.H.W.; Boshkov, N.

    2006-01-01

    An improved cathodic protection (CP), based on pulse regime was investigated in reinforced concrete, compared to conventional CP. Both regimes used CP current in the range of 2 to15 mA/m2. A voltage-to-current converter maintained the pulse current, the latter adjusted with duty cycle of 12% to 50 %

  13. Service-life prediction of reinforced concrete structures in subsurface environment

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Ki Jung; Jung, Hae Ryong; Park, Joo Wan [Korea Radioactive Waste Agency, Daejeon (Korea, Republic of)

    2016-03-15

    This paper focuses on the estimation of durability and service-life of reinforced concrete structures in Wolsong Low- and intermediate-level wastes Disposal Center (WLDC) in Korea. There are six disposal silos located in the saturated environment. The silo concrete is degraded due to reactions with groundwater and chemical attacks, and finally it will lose its properties as a transport barrier. The infiltration of sulfate and magnesium, leaching of potassium hydroxide, and chlorine induced corrosion are the most significant factors for degradation of reinforced concrete structure in underground environment. From the result of evaluation of the degradation time for each factor, the degradation rate of the reinforced concrete due to sulfate and magnesium is 1.308×10{sup -3} cm/yr, and it is estimated to take 48,000 years for full degradation while potassium hydroxide is leached in depth of less than 1.5 cm at 1,000 years after the initiation of degradation. In case of chlorine induced corrosion, it takes 1,648 years to initiate corrosion in the main reinforced bar and 2,288 years to reach the lifetime limit of the structural integrity, and thus it is evaluated as the most significant factor.

  14. Static, Fire and Fatigue Tests of Ultra High-Strength Fibre Reinforced Concrete and Ribbed Bars

    DEFF Research Database (Denmark)

    Hansen, Lars Pilegaard; Heshe, Gert

    2001-01-01

    - Densit Joint Cast ®. Also the connections between the columns and the slabs are made of this very strong concrete material. The paper describes some of the static tests carried out as well as some fire tests. Further, 2 chapters deal with some fatigue tests of the reinforcing bars as well as some fatigue...

  15. Modified Hydrotalcites as Smart Additives for Improved Corrosion Protection of Reinforced Concrete

    NARCIS (Netherlands)

    Yang, Z.

    2015-01-01

    Corrosion of reinforcing steel is a major culprit to durability and serviceability of concrete structures. This problem is highly relevant for civil engineering structures in the transport sector, such as bridges, tunnels, harbour quays and parking structures. The dominant aggressive external influe

  16. Response and Damage Assessment of Reinforced Concrete Frames subject to Earthquakes

    DEFF Research Database (Denmark)

    Skjærbæk, Poul

    When civil engineering structures made of reinforced concrete (RC) such as some types of apartment buildings, hospitals, office buildings, bridges etc. are subjected to sufficiently high dynamic loads it is well known that some kind of damage will occur in the structure. The damage introduced...

  17. Full-scale physical testing of a buried reinforced concrete pipe under axle load

    National Research Council Canada - National Science Library

    Lay, G.R; Brachman, R.W.I

    2014-01-01

    The structural response of a 600 mm inner diameter reinforced concrete pipe buried in a dense, well-graded sand and gravel soil and subjected to surface load from a single design truck axle with 0.3, 0.6...

  18. Recommendations for the shear assessment of reinforced concrete slab bridges from experiments

    NARCIS (Netherlands)

    Lantsoght, E.O.L.; Van der Veen, C.; Walraven, J.C.; De Boer, A.

    2013-01-01

    Upon assessment of existing reinforced concrete short-span solid slab bridges according to the recently implemented Eurocodes that include more conservative shear capacity provisions and heavier axle loads, a number of these structures were found to be shear-critical. The results from recent

  19. Local and Modal Damage Indicators for Reinforced Concrete Shear Frames Subject to Earthquakes

    DEFF Research Database (Denmark)

    Köylüoglu, H. U.; Nielsen, Søren R. K.; Abbott, J.

    Local, modal and overall damage indicators for reinforced concrete shear frames subject to seismic excitation are defined and studied. Each storey of the shear frame is represented by a Clough and Johnston hysteretic oscillator with degrading elastic fraction of the restoring force. The local max...

  20. Static And Dynamic Characteristics Of Waste Ceramic Aggregate Fibre Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Cichocki Krzysztof

    2015-12-01

    Full Text Available There are multiple obstacles associated both with technology and properties of waste ceramic aggregate concrete preventing its wide production and application. In the research programme these limitations were addressed through utilizing steel fibre reinforcement and the phenomenon of internal curing. After laboratory tests of mechanical properties a numerical analysis of composites in question was conducted.