WorldWideScience

Sample records for plant operational state

  1. Exergy analysis of the FIGUEIRA thermal power plant operation - state of Parana, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Stanescu, George; Lima, Joao E. [Parana Univ., Curitiba, PR (Brazil). Dept. de Engenharia Mecanica]. E-mails: stanescu@demec.ufpr.br; joeduli@demec.ufpr.br; Andrade, Carlos de [FIGUEIRA Thermal Power Plant, Figueira, PR (Brazil)]. E-mail: ccarlosaandrade@zipmail.com.br

    2000-07-01

    Exergy analysis is a powerful tool to evaluate, design and improve the thermal systems. The method of exergy analysis or availability analysis is well suited for furthering the goal of increasing the efficiency of existing power generation systems, and the capability of more effective energy resource use. Exergy analysis of the FIGUEIRA thermal power plant is presented. Exergy losses occurring in various components are considered and the exergy balance is shown in tabular form. Results clearly reveal that the steam generator is the principal site of thermodynamic losses, while the condenser is relatively unimportant. (author)

  2. Modeling Operating Modes for the Monju Nuclear Power Plant

    DEFF Research Database (Denmark)

    Lind, Morten; Yoshikawa, H.; Jørgensen, Sten Bay

    2012-01-01

    The specification of supervision and control tasks in complex processes requires definition of plant states on various levels of abstraction related to plant operation in start-up, normal operation and shut-down. Modes of plant operation are often specified in relation to a plant decomposition in...... for the Japanese fast breeder reactor plant MONJU....

  3. Shutdown and low-power operation at commercial nuclear power plants in the United States. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The report contains the results of the NRC Staff`s evaluation of shutdown and low-power operations at US commercial nuclear power plants. The report describes studies conducted by the staff in the following areas: Operating experience related to shutdown and low-power operations, probabilistic risk assessment of shutdown and low-power conditions and utility programs for planning and conducting activities during periods the plant is shut down. The report also documents evaluations of a number of technical issues regarding shutdown and low-power operations performed by the staff, including the principal findings and conclusions. Potential new regulatory requirements are discussed, as well as potential changes in NRC programs. A draft report was issued for comment in February 1992. This report is the final version and includes the responses to the comments along with the staff regulatory analysis of potential new requirements.

  4. Modeling Operating Modes for the Monju Nuclear Power Plant

    DEFF Research Database (Denmark)

    Lind, Morten; Yoshikawa, Hidekazu; Jørgensen, Sten Bay

    2012-01-01

    The specification of supervision and control tasks in complex processes requires definition of plant states on various levels of abstraction related to plant operation in start-up, normal operation and shut-down. Modes of plant operation are often specified in relation to a plant decomposition in...

  5. Operate a Nuclear Power Plant.

    Science.gov (United States)

    Frimpter, Bonnie J.; And Others

    1983-01-01

    Describes classroom use of a computer program originally published in Creative Computing magazine. "The Nuclear Power Plant" (runs on Apple II with 48K memory) simulates the operating of a nuclear generating station, requiring students to make decisions as they assume the task of managing the plant. (JN)

  6. Mathematical Modeling in Systems for Operational Evaluation of the Stress-Strain State of the Arch-Gravity Dam at the Sayano-Shushenskaya Hydroelectric Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Bellendir, E. N.; Gordon, L. A., E-mail: lev-gordon@mail.ru; Khrapkov, A. A.; Skvortsova, A. E., E-mail: SkvortsovaAE@vniig.ru [B. E. Vedeneev All-Russia Research Institute of Hydraulic Engineering (VNIIG) (Russian Federation)

    2017-01-15

    Current studies of the stress-strain state of the dam at the Sayano-Shushenskaya Hydroelectric Power Plant at VNIIG based on mathematical modeling including full scale and experimental data are described. Applications and programs intended for automatic operational evaluation of the stress-strain state of the dam for optimizing control of the upper race level in the course of the annual filling-drawdown cycle and during seismic events are examined. Improvements in systems for monitoring the stress-strain state of concrete dams are proposed.

  7. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1: Evaluation of severe accident risks for plant operational state 5 during a refueling outage. Main report and appendices, Volume 6, Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Brown, T.D.; Kmetyk, L.N.; Whitehead, D.; Miller, L. [Sandia National Labs., Albuquerque, NM (United States); Forester, J. [Science Applications International Corp., Albuquerque, NM (United States); Johnson, J. [GRAM, Inc., Albuquerque, NM (United States)

    1995-03-01

    Traditionally, probabilistic risk assessments (PRAS) of severe accidents in nuclear power plants have considered initiating events potentially occurring only during full power operation. Recent studies and operational experience have, however, implied that accidents during low power and shutdown could be significant contributors to risk. In response to this concern, in 1989 the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The program consists of two parallel projects being performed by Brookhaven National Laboratory (Surry) and Sandia National Laboratories (Grand Gulf). The program objectives include assessing the risks of severe accidents initiated during plant operational states other than full power operation and comparing the estimated risks with the risk associated with accidents initiated during full power operation as assessed in NUREG-1150. The scope of the program is that of a Level-3 PRA. The subject of this report is the PRA of the Grand Gulf Nuclear Station, Unit 1. The Grand Gulf plant utilizes a 3833 MWt BUR-6 boiling water reactor housed in a Mark III containment. The Grand Gulf plant is located near Port Gibson, Mississippi. The regime of shutdown analyzed in this study was plant operational state (POS) 5 during a refueling outage, which is approximately Cold Shutdown as defined by Grand Gulf Technical Specifications. The entire PRA of POS 5 is documented in a multi-volume NUREG report (NUREG/CR-6143). The internal events accident sequence analysis (Level 1) is documented in Volume 2. The Level 1 internal fire and internal flood analyses are documented in Vols 3 and 4, respectively.

  8. The NRC staff evaluation of shutdown and low-power operation at nuclear power plants in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Holahan, G.M.; Caruso, M.A. (Nuclear Regulatory Commission, Washington, DC (United States))

    1992-01-01

    The results of the US Nuclear Regulatory Commission (NRC) staff's recent evaluation of shutdown and low-power operations at US commercial nuclear power plants are summarized in this paper. The NRC staff's evaluation was initiated following their investigation of the loss during shutdown of all vital alternating current power on March 20, 1990, at the Alvin W. Vogtle nuclear plant. The objective of the evaluation has been to assess risk broadly during shutdown, refueling, and startup, addressing not only issues raised by the Vogtle event, but also a number of other shutdown-related issues that had been identified by foreign regulatory organizations as well as the NRC and any new issues uncovered in the evaluation process. The key issues concerning shutdown risk identified in the integration process described earlier and subsequently addressed by the staff include the following: (1) outage planning and control; (2) stress on personnel and programs; (3) the need to improve training and procedures; (4) technical specifications; and (5) PWR safety during midloop operation. Other technical topics identified for further study by the staff included loss of RHR, containment capability, rapid boron dilution, fire protection, instrumentation, emergency core cooling system recirculation capability, effect of PWR upper internals, on-site emergency planning, fuel handling and heavy loads, potential for draining the BWR reactor vessel, reporting requirements for shutdown events, and need to strengthen inspection program.

  9. Modeling Operating Modes for the Monju Nuclear Power Plant

    DEFF Research Database (Denmark)

    Lind, Morten; Yoshikawa, Hidekazu; Jørgensen, Sten Bay

    2012-01-01

    The specification of supervision and control tasks in complex processes requires definition of plant states on various levels of abstraction related to plant operation in start-up, normal operation and shut-down. Modes of plant operation are often specified in relation to a plant decomposition...... of the process plant, its function and its structural elements. The paper explains how the means-end concepts of MFM can be used to provide formalized definitions of plant operation modes. The paper will introduce the mode types defined by MFM and show how selected operation modes can be represented...

  10. State power plant productivity programs

    Energy Technology Data Exchange (ETDEWEB)

    1981-02-01

    The findings of a working group formed to review the status of efforts by utilities and utility regulators to increase the availability and reliability of generating units are presented. Representatives from nine state regulatory agencies, NRRI, and DOE, participated on the Working Group. The Federal government has been working cooperatively with utilities, utility organizations, and with regulators to encourage and facilitate improvements in power plant productivity. Cooperative projects undertaken with regulatory and energy commissions in California, Illinois, New York, Ohio, Texas, North Carolina and Mighigan are described. Following initiation of these cooperative projects, DOE funded a survey to determine which states were explicitly addressing power plant productivity through the regulatory process. The Working Group was formed following completion of this survey. The Working Group emphasized the need for those power plant productivity improvements which are cost effective. The cost effectiveness of proposed availability improvement projects should be determined within the context of opportunities for operating and capital improvements available to an entire utility. The Working Group also identified the need for: allowing for plant designs that have a higher construction cost, but are also more reliable; allowing for recovery and reducing recovery lags for productivity-related capital expenditures; identifying and reducing disincentives in the regulatory process; ascertaining that utilities have sufficient money available to undertake timely maintenance; and support of EPRI and NERC to develop a relevant and accurate national data base. The DOE views these as extremely important aspects of any regulatory program to improve power plant productivity.

  11. A Grid-Connected Desalination Plant Operation

    Directory of Open Access Journals (Sweden)

    Won Ko

    2013-02-01

    Full Text Available In this paper, a grid-connected desalination plant operation approach is suggested. In desalination plant, large amount of energy is needed to operate pump and motor; hence most of energy is electricity. For this reason, the largest part of the operation cost is electricity charges. To demonstrate power usage, small size desalination measuring system mounted plant is used. Finally, to show the result of a grid-connected desalination plant operation, electric tariff rate of Korea is used. The result shows that total cost reduction rate is calculated about 1.6% of annual total electric plant operation cost.

  12. Simulators predict power plant operation

    Energy Technology Data Exchange (ETDEWEB)

    Peltier, R.

    2002-07-01

    Mix the complexity of a new construction or major retrofit project with today's 'do more with less', a pinch of 'personnel inexperience,' and a dash of 'unintended consequences', and you have got a recipe for insomnia. Advanced simulation tools, however, can help you wring out your design train your operators before the first wire is terminated and just may be get a good night's rest. The article describes several examples of uses of simulation tools. Esscor recently completed a simulation project for a major US utility exploring the potential for furnace/duct implosion that could result from adding higher volumetric flow induced-draft fans and selective catalytic reduction to a 650-MW coal-fired plant. CAF Electronics Inc. provided a full-scope simulator for Alstom's KA24-1 combined-cycle power plant in Paris, France. Computational fluid dynamics (CFD) tools are being used by the Gas Technology Institute to simulate the performance of the next generation of pulverized coal combustors. 5 figs.

  13. Quantum Operations as Quantum States

    CERN Document Server

    Arrighi, P; Arrighi, Pablo; Patricot, Christophe

    2004-01-01

    In this article we formalize the correspondence between quantum states and quantum operations, and harness its consequences. This correspondence was already implicit in Choi's proof of the operator sum representation of Completely Positive-preserving linear maps; we go further and show that all of the important theorems concerning quantum operations can be derived as simple corollaries of those concerning quantum states. As we do so the discussion first provides an elegant and original review of the main features of quantum operations. Next (in the second half of the paper) we search for more results to arise from the correspondence. Thus we propose a factorizability condition and an extremal trace-preservedness condition for quantum operations, give two novel Schmidt-type decompositions of bipartite pure states and two interesting composition laws for which the set of quantum operations and quantum states remain stable. The latter enables us to define a group structure upon the set of totally entangled state...

  14. A Plant Damage State Early Warning System

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Chih Yao; Chou, Hwai Pwu [National Tsing Hua University, Hsinchu (China)

    2014-08-15

    In case of a severe accident, operators need to follow the emergency operating procedures (EOPS) to limit the damage. In order to assist operators to face a lot of Plant Damage States (PDS) suddenly, we try to predict and identify the Plant Damage State (PDS) for early warning and decision making. In this study, Containment Event Tree (CET) is used in this event-oriented approach to help severe accident management. The Taipower Lungmen nuclear power station (LNPS), an advanced boiling water reactor, is chosen for case study. The LNPS full scope engineering simulator is used to generate the testing data for method development.

  15. Modeling Operating Modes during Plant Life Cycle

    DEFF Research Database (Denmark)

    Jørgensen, Sten Bay; Lind, Morten

    2012-01-01

    Modelling process plants during normal operation requires a set a basic assumptions to define the desired functionalities which lead to fullfillment of the operational goal(-s) for the plant. However during during start-up and shut down as well as during batch operation an ensemble of interrelate...

  16. State Energy Program Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Office of Building Technology, State and Community Programs

    1999-03-17

    The State Energy Program Operations Manual is a reference tool for the states and the program officials at the U.S. Department of Energy's Office of Building Technology, State and Community Programs and Regional Support Offices as well as State Energy Offices. The Manual contains information needed to apply for and administer the State Energy Program, including program history, application rules and requirements, and program administration and monitoring requirements.

  17. Knowledge representation for integrated plant operation and maintenance

    DEFF Research Database (Denmark)

    Lind, Morten

    2010-01-01

    Integrated operation and maintenance of process plants has many advantages. One advantage is the improved economy obtained by reducing the number of plant shutdowns. Another is to increase reliability of operation by monitoring of risk levels during on-line maintenance. Integrated plant operation...... and maintenance require knowledge bases which can capture the interactions between the two plant activities. As an example, taking out a component or a subsystem for maintenance during operation will require a knowledge base representing the interactions between plant structure, functions, operating states...... and goals and incorporate knowledge about redundancy and reliability data. Multilevel Flow Modeling can be used build knowledge bases representing plant goals and functions and has been applied for fault diagnosis and supervisory control but currently it does not take into account structural information...

  18. Nuclear power plant operation 2016. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2017-05-15

    A report is given on the operating results achieved in 2016, events important to plant safety, special and relevant repair, and retrofit measures from nuclear power plants in Germany. Reports about nuclear power plants in Belgium, Finland, the Netherlands, Switzerland, and Spain will be published in a further issue.

  19. Operational management in pot plant production

    NARCIS (Netherlands)

    Leutscher, K.J.

    1995-01-01

    Operational management in pot plant production was investigated by means of system analysis and simulation. A theoretical framework for operational decision-making consisted of elaboration decisions, progress decisions, and adoption decisions. This framework was incorporated in a pot plant

  20. Thermal power plant design and operation

    CERN Document Server

    Sarkar, Dipak

    2015-01-01

    Thermal Power Plant: Design and Operation deals with various aspects of a thermal power plant, providing a new dimension to the subject, with focus on operating practices and troubleshooting, as well as technology and design. Its author has a 40-long association with thermal power plants in design as well as field engineering, sharing his experience with professional engineers under various training capacities, such as training programs for graduate engineers and operating personnel. Thermal Power Plant presents practical content on coal-, gas-, oil-, peat- and biomass-fueled thermal power

  1. Applied math for wastewater plant operators

    CERN Document Server

    Price, Joanne K

    1998-01-01

    With many worked examples, this book provides step-by-step instruction for all calculations required for wastewater treatment. Pertinent calculations are conveniently summarized in each chapter. The text covers all the fundamental math concepts and skills needed for daily wastewater treatment plant operations. The workbook for this book can be purchased separately or together in the Applied Math for Wastewater Plant Operators Set (ISBN: 9781566769891).

  2. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1. Volume 5: Analysis of core damage frequency from seismic events for plant operational state 5 during a refueling outage

    Energy Technology Data Exchange (ETDEWEB)

    Budnitz, R.J. [Future Resources Associates, Inc., Berkeley, CA (United States); Davis, P.R. [PRD Consulting (United States); Ravindra, M.K.; Tong, W.H. [EQE International, Inc., Irvine, CA (United States)

    1994-08-01

    In 1989 the US Nuclear Regulatory Commission (NRC) initiated an extensive program to examine carefully the potential risks during low-power and shutdown operations. The program included two parallel projects, one at Sandia National Laboratories studying a boiling water reactor (Grand Gulf), and the other at Brookhaven National Laboratory studying a pressurized water reactor (Surry Unit 1). Both the Sandia and Brookhaven projects have examined only accidents initiated by internal plant faults---so-called ``internal initiators.`` This project, which has explored the likelihood of seismic-initiated core damage accidents during refueling outage conditions, is complementary to the internal-initiator analyses at Brookhaven and Sandia. This report covers the seismic analysis at Grand Gulf. All of the many systems modeling assumptions, component non-seismic failure rates, and human effort rates that were used in the internal-initiator study at Grand Gulf have been adopted here, so that the results of the study can be as comparable as possible. Both the Sandia study and this study examine only one shutdown plant operating state (POS) at Grand Gulf, namely POS 5 representing cold shutdown during a refueling outage. This analysis has been limited to work analogous to a level-1 seismic PRA, in which estimates have been developed for the core-damage frequency from seismic events during POS 5. The results of the analysis are that the core-damage frequency for earthquake-initiated accidents during refueling outages in POS 5 is found to be quite low in absolute terms, less than 10{sup {minus}7}/year.

  3. Research of the Power Plant Operational Modes

    Directory of Open Access Journals (Sweden)

    Koismynina Nina M.

    2017-01-01

    Full Text Available In this article the algorithm of the power plant operational modes research is offered. According to this algorithm the program for the modes analysis and connection power transformers choice is developed. The program can be used as educational means for studying of the power plant electric part, at the same time basic data are provided. Also the program can be used for the analysis of the working power plants modes. Checks of the entered data completeness and a choice correctness of the operational modes are provided in the program; in all cases of a deviation from the correct decisions to the user the relevant information is given.

  4. Water Treatment Technology - General Plant Operation.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on general plant operations provides instructional materials for seven competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: water supply regulations, water plant…

  5. Nuclear power plant operation and training

    Energy Technology Data Exchange (ETDEWEB)

    Sanae, Katsushige [Tokyo Electric Power Co., Inc. (Japan); Mitsumori, Kojiro

    1997-07-01

    In this report, the system for operation of a nuclear power plant and the qualities required for its operators were summarized. In Kashiwazaki-Kariwa Atomic Power Plant of the Tokyo Electric Power Co., Inc. operation is continuously made by 6 groups containing each 10 workers on three shifts. A group including the person in charge participates in the operation through cooperation of the control center and the respective spots. The group leaders are chosen from those approved as a person responsible to its operation. The conditions for the person responsible were as follows: to receive simulator training for senior operator, to have more than 7 years experience of operating a nuclear power plant, to pass a practical examination on the ordinary operation and the emergency one, to receive a training course to master the knowledge and techniques for operating an atomic reactor and to success the oral examination on practical knowledge required to perform the duty. Further, the simulators for ABWR training produced by Toshiba Corp. and Hitachi Ltd. were introduced as an example. And the practical training procedures to manipulate the simulator were presented. (M.N.)

  6. Manual of Operations for the S-50 Plant

    Energy Technology Data Exchange (ETDEWEB)

    Overman R.T.

    1945-06-01

    It is recognized that the S-50 plant operations are far from standardized and therefore any manual will require continual revision to keep it up to date. Even during the period of writing this first edition, many changes occurred and were incorporated in the manual. Such revisions could delay indefinitely the issuance of the manual and it was felt that in its present form it could be useful in the training of new plant personnel. The specific purpose of the process employed by the Ferclave Corporation in the plant at Oak Ridge, Tennessee, is one of secret information and cannot be released here. It can be stated, however, that the plant operation involves the processing of a chemical substance. This substance is not identified in the plant or in the process but is referred to only as 'material'. Its code designation is C-616. The process in general involves the separation of the raw material into constituents with more desirable properties. It is not necessary to know the name of the material nor the exact nature of the process in order to carry out the operations so this information will not be given in this Manual. The problem involved is to transport the material from the containers in which it is received by the plant into equipment set-up in the plant for carrying out the operation, to remove the various products from the process equipment and to do other auxiliary operations.

  7. Computer simulation of thermal plant operations

    CERN Document Server

    O'Kelly, Peter

    2012-01-01

    This book describes thermal plant simulation, that is, dynamic simulation of plants which produce, exchange and otherwise utilize heat as their working medium. Directed at chemical, mechanical and control engineers involved with operations, control and optimization and operator training, the book gives the mathematical formulation and use of simulation models of the equipment and systems typically found in these industries. The author has adopted a fundamental approach to the subject. The initial chapters provide an overview of simulation concepts and describe a suitable computer environment.

  8. Operational development of small plant growth systems

    Science.gov (United States)

    Scheld, H. W.; Magnuson, J. W.; Sauer, R. L.

    1986-01-01

    The results of a study undertaken on the first phase of an empricial effort in the development of small plant growth chambers for production of salad type vegetables on space shuttle or space station are discussed. The overall effort is visualized as providing the underpinning of practical experience in handling of plant systems in space which will provide major support for future efforts in planning, design, and construction of plant-based (phytomechanical) systems for support of human habitation in space. The assumptions underlying the effort hold that large scale phytomechanical habitability support systems for future space stations must evolve from the simple to the complex. The highly complex final systems will be developed from the accumulated experience and data gathered from repetitive tests and trials of fragments or subsystems of the whole in an operational mode. These developing system components will, meanwhile, serve a useful operational function in providing psychological support and diversion for the crews.

  9. Operational energy performance assessment system of municipal wastewater treatment plants.

    Science.gov (United States)

    Yang, Lingbo; Zeng, Siyu; Chen, Jining; He, Miao; Yang, Wan

    2010-01-01

    Based on the statistical analysis of operational energy consumption and its influential factors from data of 599 Chinese WWTPs in 2006, it is noticed that the most influential factors include treatment technology adopted, treated sewage amount, removed pollutants amount, etc. Using the conclusion above, this paper sets up an integrated system of operational energy performance assessment for municipal wastewater treatment plants. Combining with result from on-spot research and model simulation, the calculating method of benchmark value and score of 7 energy efficiency indicators grouped into 3 levels is stated. Applying the assessment system to three plants, its applicability and objectivity are proved and suggestions to improve energy performance are provided.

  10. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1: Evaluation of severe accident risks for plant operational state 5 during a refueling outage. Supporting MELCOR calculations, Volume 6, Part 2

    Energy Technology Data Exchange (ETDEWEB)

    Kmetyk, L.N.; Brown, T.D. [Sandia National Labs., Albuquerque, NM (United States)

    1995-03-01

    To gain a better understanding of the risk significance of low power and shutdown modes of operation, the Office of Nuclear Regulatory Research at the NRC established programs to investigate the likelihood and severity of postulated accidents that could occur during low power and shutdown (LP&S) modes of operation at commercial nuclear power plants. To investigate the likelihood of severe core damage accidents during off power conditions, probabilistic risk assessments (PRAs) were performed for two nuclear plants: Unit 1 of the Grand Gulf Nuclear Station, which is a BWR-6 Mark III boiling water reactor (BWR), and Unit 1 of the Surry Power Station, which is a three-loop, subatmospheric, pressurized water reactor (PWR). The analysis of the BWR was conducted at Sandia National Laboratories while the analysis of the PWR was performed at Brookhaven National Laboratory. This multi-volume report presents and discusses the results of the BWR analysis. The subject of this part presents the deterministic code calculations, performed with the MELCOR code, that were used to support the development and quantification of the PRA models. The background for the work documented in this report is summarized, including how deterministic codes are used in PRAS, why the MELCOR code is used, what the capabilities and features of MELCOR are, and how the code has been used by others in the past. Brief descriptions of the Grand Gulf plant and its configuration during LP&S operation and of the MELCOR input model developed for the Grand Gulf plant in its LP&S configuration are given.

  11. Operating experience from Swedish nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-06-01

    During 1997 the PWRs in Ringhals performed extremely well (capability factors 85-90%), the unit Ringhals 2 reached the best capability factor since commercial operation started in 1976. The BWRs made an average 76% capability, which is somewhat less than in 1996. The slightly reduced capability derives from ongoing modernization projects at several units. At the youngest plants, Forsmark 3 and Oskarshamn 3, capability and utilization were very high. Events and data for 1997 are given for each reactor, together with operational statistics for the years 1990-1997. A number of safety-related events are reported, which occurred st the Swedish plants during 1997. These events are classified as level 1 or higher on the international nuclear event scale (INES).

  12. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1: Analysis of core damage frequency from internal events for Plant Operational State 5 during a refueling outage. Volume 2, Part 3: Internal Events Appendices I and J

    Energy Technology Data Exchange (ETDEWEB)

    Yakle, J. [Science Applications International Corp., Albuquerque, NM (United States); Darby, J. [Science and Engineering Associates, Inc., Albuquerque, NM (United States); Whitehead, D.; Staple, B. [Sandia National Labs., Albuquerque, NM (United States)

    1994-06-01

    This report provides supporting documentation for various tasks associated with the performance of the probablistic risk assessment for Plant Operational State 5 during a refueling outage at Grand Gulf, Unit 1 as documented in Volume 2, Part 1 of NUREG/CR-6143.

  13. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1. Volume 2, Part 1C: Analysis of core damage frequency from internal events for plant operational State 5 during a refueling outage, Main report (Sections 11--14)

    Energy Technology Data Exchange (ETDEWEB)

    Whitehead, D. [Sandia National Labs., Albuquerque, NM (United States); Darby, J. [Science and Engineering Associates, Inc., Albuquerque, NM (United States); Yakle, J. [Science Applications International Corp., Albuquerque, NM (United States)] [and others

    1994-06-01

    This document contains the accident sequence analysis of internally initiated events for Grand Gulf, Unit 1 as it operates in the Low Power and Shutdown Plant Operational State 5 during a refueling outage. The report documents the methodology used during the analysis, describes the results from the application of the methodology, and compares the results with the results from two full power analyses performed on Grand Gulf.

  14. Operating experience with nuclear power plants 2015. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2016-07-01

    The VGB Technical Committee ''Nuclear Plant Operation'' has been exchanging operating experience about nuclear power plants for more than 30 years. Plant operators from several European countries are participating in the exchange. A report is given on the operating results achieved in 2015, events important to plant safety, special and relevant repair, and retrofit measures from Germany. The second part of this report will focus on nuclear power plant in Belgium, Finland, the Netherlands, Switzerland, and Spain.

  15. Toxic plants of the Northeastern United States.

    Science.gov (United States)

    Bischoff, Karyn; Smith, Mary C

    2011-07-01

    This article lists commonly encountered toxic plants that affect ruminants in the Northeastern United States. Livestock are at risk for ingestion of a large variety of toxic plants. Plant poisonings are likely to be underdiagnosed because tests for most plant toxins are not routinely available at veterinary diagnostic laboratories. Prevention of access to poisonous plants is usually more effective and economical than treatment of plant poisonings. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Remote Operation on Quantum State Among Multiparty

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    In this paper, a scheme is proposed for performing remote operation on quantum state among multiparty.We use three-particle GHZ state as quantum channels to prepare a state operator, which describes quantum correlation between states and operations. Based on the special characteristic of the state operator, observers can perform unitary operation on a system that is away from observers. Our studies show this process is deterministic. We further consider remote operation among N spatially distributed observers, and the results show the successful realization of remote operation needs collective participation of N parties, that is, there exists strong correlation among multiparty. In addition, we investigate the case in which observers share a three-particle W state as quantum channels to perform remote operation and studies find this process is probabilistic.

  17. EXAMINING CONCEPT OF OPERATIONS IN FUTURE PLANTS.

    Energy Technology Data Exchange (ETDEWEB)

    O' HARA,J.M.HIGGINS,J.BROWN,W.KRAMER,J.PERSENSKY,J.

    2004-09-19

    This paper will examine the results of this research that focus on future concepts of operations. Our approach was to look at current technological developments in the areas of reactor technology, I&C technology, and human-system integration technology and to make projections into the near and longer-term future concerning their potential impact on human performance. The results were discussed in terms of three aspects of concepts of operations: functional staffing models, plant automation, and training and qualifications. Significant changes to each are anticipated and discussed. Research will be needed to address these changes in order to provide for confidence that changes to concepts of operations are accomplished in ways that maintain public safety.

  18. State Operations and Technical Assistance (SOTA) Contacts

    Data.gov (United States)

    U.S. Department of Health & Human Services — The State Operations and Technical Assistance (SOTA) initiative was created to work through policy and operational changes required in Medicaid by the Affordable...

  19. China’s Nuclear Power Plants in Operation

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Qinshan Plant Phase I Located in Haiyan,Zhejiang Province,Qinshan Nuclear Power Plant Phase I is t he first 300-megawatt pressurized water reactor (PWR) nuclear power plant independently designed,constructed,operated and managed by China.The plant came into commercial operation in April 1994.

  20. A State Cyber Hub Operations Framework

    Science.gov (United States)

    2016-06-01

    level cyber operations from state information technology (IT) and network infrastructure to hospitals , commercial banking, and manufacturing the...tools - TTPs necessary to operate and maintain Authoritative Data Repository for operational related artifacts . - Monitor and report on operations...development of Data Repository structures to enable storage of Cyber Hub related artifacts . - Provides Technical input to Business Case Analyses (BCAs

  1. Data analytics for drilling operational states classifications

    OpenAIRE

    Veres, Galina; Sabeur, Zoheir

    2015-01-01

    This paper provides benchmarks for the identification of best performance classifiers for the detection of operational states in industrial drilling operations. Multiple scenarios for the detection of the operational states are tested on a rig with various drilling wells. Drilling data are extremely challenging due to their non-linear and stochastic natures, notwithstanding the embedded noise in them and unbalancing. Nevertheless, there is a possibility to deploy robust classifiers to overcom...

  2. Evolution of the future plants operation for a better safety

    Energy Technology Data Exchange (ETDEWEB)

    Papin, B.; Malvache, P.

    1994-12-31

    This paper describes a coordinated research project of the french CEA, addressing to the evolutions in plant operation apt to bring perceptible and assessable improvement in the operational safety. This program has been scheduled for the 1992-1996 period, with a global 40 men/year effort. The present status of the two main parts of the project is presented: ESCRIME (program aiming at defining the optimal share of tasks between humans and computers in plant operation), IMAGIN (research in the domain of plant information management, in order to ensure the global coherence of the image of the plant, used by the different actors in plant operation). (authors). 3 refs., 4 figs.

  3. Mineral operations outside the United States

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Mineral facilities and operations outside the United States compiled by the National Minerals Information Center of the USGS. This representation combines source...

  4. Floating plant dominance as a stable state

    Science.gov (United States)

    Scheffer, Marten; Szabó, Sándor; Gragnani, Alessandra; van Nes, Egbert H.; Rinaldi, Sergio; Kautsky, Nils; Norberg, Jon; Roijackers, Rudi M. M.; Franken, Rob J. M.

    2003-01-01

    Invasion by mats of free-floating plants is among the most important threats to the functioning and biodiversity of freshwater ecosystems ranging from temperate ponds and ditches to tropical lakes. Dark, anoxic conditions under thick floating-plant cover leave little opportunity for animal or plant life, and they can have large negative impacts on fisheries and navigation in tropical lakes. Here, we demonstrate that floating-plant dominance can be a self-stabilizing ecosystem state, which may explain its notorious persistence in many situations. Our results, based on experiments, field data, and models, represent evidence for alternative domains of attraction in ecosystems. An implication of our findings is that nutrient enrichment reduces the resilience of freshwater systems against a shift to floating-plant dominance. On the other hand, our results also suggest that a single drastic harvest of floating plants can induce a permanent shift to an alternative state dominated by rooted, submerged growth forms. PMID:12634429

  5. 76 FR 36917 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for...

    Science.gov (United States)

    2011-06-23

    ... AGENCY Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for TransAlta Centralia Generation, LLC--Coal- Fired Power Plant AGENCY: Environmental Protection Agency (EPA... to a citizen petition asking EPA to object to an operating permit issued by the Southwest Clean...

  6. Taxonomy of the nuclear plant operator's role

    Energy Technology Data Exchange (ETDEWEB)

    Kisner, R.A.; Fullerton, A.M.; Frey, P.R.; Dougherty, E.M.

    1981-01-01

    A program is presently under way at the Oak Ridge National Laboratory (ORNL) to define the functional design requirements of operational aids for nuclear power plant operators. A first and important step in defining these requirements is to develop an understanding of the operator's role or function. This paper describes a taxonomy of operator functions that applies during all operational modes and conditions of the plant. Other topics such as the influence of automation, role acceptance, and the operator's role during emergencies are also discussed. This systematic approach has revealed several areas which have potential for improving the operator's ability to perform his role.

  7. Process plant equipment operation, control, and reliability

    CERN Document Server

    Holloway, Michael D; Onyewuenyi, Oliver A

    2012-01-01

    "Process Plant Equipment Book is another great publication from Wiley as a reference book for final year students as well as those who will work or are working in chemical production plants and refinery…" -Associate Prof. Dr. Ramli Mat, Deputy Dean (Academic), Faculty of Chemical Engineering, Universiti Teknologi Malaysia "…give[s] readers access to both fundamental information on process plant equipment and to practical ideas, best practices and experiences of highly successful engineers from around the world… The book is illustrated throughout with numerous black & white p

  8. Scalar operators in solid-state NMR

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Boqin

    1991-11-01

    Selectivity and resolution of solid-state NMR spectra are determined by dispersion of local magnetic fields originating from relaxation effects and orientation-dependent resonant frequencies of spin nuclei. Theoretically, the orientation-dependent resonant frequencies can be represented by a set of irreducible tensors. Among these tensors, only zero rank tensors (scalar operators) are capable of providing high resolution NMR spectra. This thesis presents a series of new developments in high resolution solid-state NMR concerning the reconstruction of various scalar operators motion in solid C{sub 60} is analyzed.

  9. Water/Wastewater Treatment Plant Operator Qualifications.

    Science.gov (United States)

    Water and Sewage Works, 1979

    1979-01-01

    This article summarizes in tabular form the U.S. and Canadian programs for classification of water and wastewater treatment plant personnel. Included are main characteristics of the programs, educational and experience requirements, and indications of requirement substitutions. (CS)

  10. Operator properties of generalized coherent state systems

    Indian Academy of Sciences (India)

    N Mukunda

    2001-02-01

    The main properties of standard quantum mechanical coherent states and the two generalizations of Klauder and of Perelomov are reviewed. For a system of generalized coherent states in the latter sense, necessary and sufficient conditions for existence of a diagonal coherent stable representation for all Hilbert-Schmidt operators are obtained. The main ingredients are Clebsch-Gordan theory and induced representation theory.

  11. Yannawa wastewater treatment plant (Bangkok, Thailand): design, construction and operation.

    Science.gov (United States)

    Kirkwood, S

    2004-01-01

    Yannawa Wastewater Treatment plant (Phase 1) serves a population equivalent of 500,000 and is located on a restricted site within the city of Bangkok, Thailand. Secondary treatment is based on the CASS sequencing batch reactor (SBR) process and the plant is one of the largest multi-storey SBRs in the world. The limitation of available site area, the ground conditions and the characteristics of the wastewater to be treated set a series of challenges for the designers, contractors and commissioning and operational staff. This paper briefly describes the collection system, the process selection and the treatment streams of the wastewater treatment plant. The SBR secondary treatment plant is described in more detail. The problems that arose during commissioning and operation and the solutions made possible by the use of an SBR type of process are discussed. Details of plant performance during performance testing and during the first three years of plant operation are provided.

  12. Accelerating progress toward operational excellence of fossil energy plants with CO2 capture

    Energy Technology Data Exchange (ETDEWEB)

    Zitney, S.; Liese, E.; Mahapatra, P.; Turton, R. Bhattacharyya, D.

    2012-01-01

    To address challenges in attaining operational excellence for clean energy plants, the National Energy Technology Laboratory has launched a world-class facility for Advanced Virtual Energy Simulation Training And Research (AVESTARTM). The AVESTAR Center brings together state-of-the-art, real-time, high-fidelity dynamic simulators with operator training systems and 3D virtual immersive training systems into an integrated energy plant and control room environment. This paper will highlight the AVESTAR Center simulators, facilities, and comprehensive training, education, and research programs focused on the operation and control of an integrated gasification combined cycle power plant (IGCC) with carbon dioxide capture.

  13. Improvement of operational efficiency based on fast startup plant concepts

    Energy Technology Data Exchange (ETDEWEB)

    Kurz, Harald; Meinecke, Gero; Ohresser, Sylvia; Pickard, Andreas

    2010-09-15

    One of the major global challenges of the present time is the reduction of CO2 emissions. Provisions for integration of a CO2 capture plant are already required today in new power plant construction projects in order to enable current plants to also benefit from the possibilities of carbon capture systems to be developed in the future. These provisions for integration should account for the fact that the scrubbing processes are still in the optimization phase. Requisite process parameters may still change in the future. In the development of a plant interface, the paper describes a concept developed by Siemens which ensures maximum flexibility with simultaneous optimization of the plant for the capture process. Emphasis was placed on the following points in the development of this interface and the associated connection concepts: Maximum plant efficiency before and after modification; Maximum flexibility with regard to future process parameters; Optimization of customer investment cash flow; and, Applicability also to existing plants. According to the paper, Siemens can offer a concept which enables future conversion in accordance with the specified criteria. This concept requires no compromises with regard to plant efficiency in process optimization for either current power plant operation without carbon capture or for future operation with carbon capture. The concept also enables retrofitting of existing plants which are not yet capture-ready. However, retrofitting of power plants which are not prepared for operation with carbon capture is considerably more elaborate in most cases, as corridors must frequently still be cleared for the connecting piping.

  14. Industrial Fuel Gas Demonstration Plant Program. Demonstration plant operation plan (Deliverable No. 38)

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-01-01

    The Demo Plant Operating Plan is composed of the following sequence of events starting with the training or personnel, familiarizing of the personnel with the plant and completing the long-term run in the following sequences: inspection during construction, plant completion, shakedown of equipment, process unit startup, shakedown of process units, variable run operation and a turnaround. During the construction period, technical personnel from DRC, MLGW and IGT will be at the plant site becoming familiar with the equipment, its installation and all of the auxiliaries so that on completion of construction they will be well grounded on the plant detail and its configuration. At the same time the supervisory operating personnel will have hands on training the gasifier operation at the IGT pilot plant to develop a field for gasifier operation. As a plant sections are completed, they will be checked out in accordance with the contractor and operator (client) procedure as outlined. Subsequent to this, various vendor designs and furnished equipment will be checked out operating-wise and a performance test run if feasible. The actual startup of the plant will be subsequential with the support areas as utilities, coal handling and waste treatment being placed in operation first. Subsequent to this the process units will be placed in operation starting from the rear of the process train and working forward. Thus the downstream units will be operating before the reactor is run on coal. The reactor will be checked out on coke operation.

  15. User Charge Revenues for Wastewater Treatment Plants--Insufficient to Cover Operation and Maintenance.

    Science.gov (United States)

    1981-12-02

    AD-All 588 SEMERAL ACCOUNTINq OFFICE WASHINGTON DC COMUNITY AN--ETC F/S 13/2 USER CHARGE REVENUES FOR WASTEWATER TREATMENT PLANTS--INSUFFICI--ETC(U...COMPTROLLER GENERAL 0 Report To The Congress OF THE UNITED STATES User Charge Revenues For Wastewater = Treatment Piants-Insutficient To Cover Operation And...Maintenance Half of the 36 municipal wastewater treatment plants GAO reviewed in 10 States were not raising sufficient funds from their user charge iP

  16. Nuclear plant operation: achieving excellence through quality

    Energy Technology Data Exchange (ETDEWEB)

    Bergstrom, L. [Barseback Nuclear Power Plant (Sweden); Bergeron, J.P. [Electricite de France (EDF), 75 - Paris (France); Coakley, W. [and others

    1992-07-01

    Nuclear power operation is characterised by a very high level of safety and availability resulting in economically competitive electricity production. This achievement must not only be maintained but must be further developed if nuclear power is to regain momentum in the light of its widely recognized environmental advantages. Therefore this meeting bring together all those, managers and technical staff, responsible for the operation of the nuclear in order to allow them to exchange views, experience and knowledge on fundamental aspects such as: management philosophy, quality assurance, human resources and international co-operation; focusing on training (incident analysis and management), human factors and experience feedback; maintenance philosophy, life extension and upgrading, organisation and administration. (A.L.B.)

  17. ESCRIME: testing bench for advanced operator workstations in future plants

    Energy Technology Data Exchange (ETDEWEB)

    Poujol, A.; Papin, B. [CEA Centre d`Etudes Nucleaires de Cadarache, 13 - Saint-Paul-lez-Durance (France)

    1994-12-31

    The problem of optimal task allocation between man and computer for the operation of nuclear power plants is of major concern for the design of future plants. As the increased level of automation induces the modification of the tasks actually devoted to the operator in the control room, it is very important to anticipate these consequences at the plant design stage. The improvement of man machine cooperation is expected to play a major role in minimizing the impact of human errors on plant safety. The CEA has launched a research program concerning the evolution of the plant operation in order to optimize the efficiency of the human/computer systems for a better safety. The objective of this program is to evaluate different modalities of man-machine share of tasks, in a representative context. It relies strongly upon the development of a specific testing facility, the ESCRIME work bench, which is presented in this paper. It consists of an EDF 1300MWe PWR plant simulator connected to an operator workstation. The plant simulator model presents at a significant level of details the instrumentation and control of the plant and the main connected circuits. The operator interface is based on the generalization of the use of interactive graphic displays, and is intended to be consistent to the tasks to be performed by the operator. The functional architecture of the workstation is modular, so that different cooperation mechanisms can be implemented within the same framework. It is based on a thorough analysis and structuration of plant control tasks, in normal as well as in accident situations. The software architecture design follows the distributed artificial intelligence approach. Cognitive agents cooperate in order to operate the process. The paper presents the basic principles and the functional architecture of the test bed and describes the steps and the present status of the program. (author).

  18. Davis PV plant operation and maintenance manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-09-01

    This operation and maintenance manual contains the information necessary to run the Photovoltaics for Utility Scale Applications (PVUSA) test facility in Davis, California. References to more specific information available in drawings, data sheets, files, or vendor manuals are included. The PVUSA is a national cooperative research and demonstration program formed in 1987 to assess the potential of utility scale photovoltaic systems.

  19. Operator Training Simulator for an Industrial Bioethanol Plant

    OpenAIRE

    Inga Gerlach; Sören Tholin; Hass, Volker C; Carl-Fredrik Mandenius

    2016-01-01

    Operator training simulators (OTS) are software tools for training process operators in large-scale industrial applications. Here, we describe the development, implementation and training of an OTS for a large-scale industrial plant for bioethanol production. The design of the OTS is based on conceptual analysis (previously reported by us in this journal) of various configuration alternatives and training procedures at the plant. In this article, we report on how the conceptual design is used...

  20. The United States Military and Humanitarian Operations

    Science.gov (United States)

    1995-01-01

    stated that, "The wave of the future will be putting together task forces that will be able to respond to crisis management or humanitarian...examine three options for the military’s role in humanitaria operations at home and abroad. Option 1: Virtually Eliminate Anv Military Role This is the...humanitarian aid in almost any crisis .36 The military resists the creation of specially designated units because such specialization reduces the

  1. Investment and operating costs of binary cycle geothermal power plants

    Science.gov (United States)

    Holt, B.; Brugman, J.

    1974-01-01

    Typical investment and operating costs for geothermal power plants employing binary cycle technology and utilizing the heat energy in liquid-dominated reservoirs are discussed. These costs are developed as a function of reservoir temperature. The factors involved in optimizing plant design are discussed. A relationship between the value of electrical energy and the value of the heat energy in the reservoir is suggested.

  2. US nuclear power plant operating cost and experience summaries

    Energy Technology Data Exchange (ETDEWEB)

    Kohn, W.E.; Reid, R.L.; White, V.S.

    1998-02-01

    NUREG/CR-6577, U.S. Nuclear Power Plant Operating Cost and Experience Summaries, has been prepared to provide historical operating cost and experience information on U.S. commercial nuclear power plants. Cost incurred after initial construction are characterized as annual production costs, representing fuel and plant operating and maintenance expenses, and capital expenditures related to facility additions/modifications which are included in the plant capital asset base. As discussed in the report, annual data for these two cost categories were obtained from publicly available reports and must be accepted as having different degrees of accuracy and completeness. Treatment of inconclusive and incomplete data is discussed. As an aid to understanding the fluctuations in the cost histories, operating summaries for each nuclear unit are provided. The intent of these summaries is to identify important operating events; refueling, major maintenance, and other significant outages; operating milestones; and significant licensing or enforcement actions. Information used in the summaries is condensed from annual operating reports submitted by the licensees, plant histories contained in Nuclear Power Experience, trade press articles, and the Nuclear Regulatory Commission (NRC) web site (www.nrc.gov).

  3. Operation of Wastewater Treatment Plants, Manual of Practice No. 11.

    Science.gov (United States)

    Albertson, Orrie E.; And Others

    This book is intended to be a reference or textbook on the operation of wastewater treatment plants. The book contains thirty-one chapters and three appendices and includes the description, requirements, and latest techniques of conventional unit process operation, as well as the symptoms and corrective measures regarding process problems. Process…

  4. Operation of Wastewater Treatment Plants: A Home Study Training Program.

    Science.gov (United States)

    California State Univ., Sacramento. Dept. of Civil Engineering.

    This manual was prepared by experienced wastewater treatment plant operators to provide a home study course to develop new qualified workers and expand the abilities of existing workers. The objective of this manual is to provide the knowledge and skills necessary for certification. Participants learn the basic operational aspects of treatment…

  5. Remote Sensing and Modeling for Improving Operational Aquatic Plant Management

    Science.gov (United States)

    Bubenheim, Dave

    2016-01-01

    The California Sacramento-San Joaquin River Delta is the hub for California’s water supply, conveying water from Northern to Southern California agriculture and communities while supporting important ecosystem services, agriculture, and communities in the Delta. Changes in climate, long-term drought, water quality changes, and expansion of invasive aquatic plants threatens ecosystems, impedes ecosystem restoration, and is economically, environmentally, and sociologically detrimental to the San Francisco Bay/California Delta complex. NASA Ames Research Center and the USDA-ARS partnered with the State of California and local governments to develop science-based, adaptive-management strategies for the Sacramento-San Joaquin Delta. The project combines science, operations, and economics related to integrated management scenarios for aquatic weeds to help land and waterway managers make science-informed decisions regarding management and outcomes. The team provides a comprehensive understanding of agricultural and urban land use in the Delta and the major water sheds (San Joaquin/Sacramento) supplying the Delta and interaction with drought and climate impacts on the environment, water quality, and weed growth. The team recommends conservation and modified land-use practices and aids local Delta stakeholders in developing management strategies. New remote sensing tools have been developed to enhance ability to assess conditions, inform decision support tools, and monitor management practices. Science gaps in understanding how native and invasive plants respond to altered environmental conditions are being filled and provide critical biological response parameters for Delta-SWAT simulation modeling. Operational agencies such as the California Department of Boating and Waterways provide testing and act as initial adopter of decision support tools. Methods developed by the project can become routine land and water management tools in complex river delta systems.

  6. Optimizing power plant cycling operations while reducing generating plant damage and costs

    Energy Technology Data Exchange (ETDEWEB)

    Lefton, S.A.; Besuner, P.H.; Grimsrud, P. [Aptech Engineering Services, Inc., Sunnyvale, CA (United States); Bissel, A. [Electric Supply Board, Dublin (Ireland)

    1998-12-31

    This presentation describes a method for analyzing, quantifying, and minimizing the total cost of fossil, combined cycle, and pumped hydro power plant cycling operation. The method has been developed, refined, and applied during engineering studies at some 160 units in the United States and 8 units at the Irish Electric Supply Board (ESB) generating system. The basic premise of these studies was that utilities are underestimating the cost of cycling operation. The studies showed that the cost of cycling conventional boiler/turbine fossil power plants can range from between $2,500 and $500,000 per start-stop cycle. It was found that utilities typically estimate these costs by factors of 3 to 30 below actual costs and, thus, often significantly underestimate their true cycling costs. Knowledge of the actual, or total, cost of cycling will reduce power production costs by enabling utilities to more accurately dispatch their units to manage unit life expectancies, maintenance strategies and reliability. Utility management responses to these costs are presented and utility cost savings have been demonstrated. (orig.) 7 refs.

  7. Steam generator tube degradation at the Doel 4 plant influence on plant operation and safety

    Energy Technology Data Exchange (ETDEWEB)

    Scheveneels, G. [AIB-Vincotte Nuclear, Brussels (Belgium)

    1997-02-01

    The steam generator tubes of Doel 4 are affected by a multitude of corrosion phenomena. Some of them have been very difficult to manage because of their extremely fast evolution, non linear evolution behavior or difficult detectability and/or measurability. The exceptional corrosion behavior of the steam generator tubes has had its drawbacks on plant operation and safety. Extensive inspection and repair campaigns have been necessary and have largely increased outage times and radiation exposure to personnel. Although considerable effort was invested by the utility to control corrosion problems, non anticipated phenomena and/or evolution have jeopardized plant safety. The extensive plugging and repairs performed on the steam generators have necessitated continual review of the design basis safety studies and the adaptation of the protection system setpoints. The large asymmetric plugging has further complicated these reviews. During the years many preventive and recently also defence measures have been implemented by the utility to manage corrosion and to decrease the probability and consequences of single or multiple tube rupture. The present state of the Doel 4 steam generators remains troublesome and further examinations are performed to evaluate if continued operation until June `96, when the steam generators will be replaced, is justified.

  8. Overview of recent operating experience regarding plant aging

    Energy Technology Data Exchange (ETDEWEB)

    Holahan, G.M.; Caruso, M.A.

    1988-06-01

    Recent, as well as past, studies of reactor trip frequencies and other types of operating experience have shown that relatively high frequencies are likely in new plants with little accumulated operating time. In order to better understand all the factors which contribute to high frequencies in new plants, the authors have made a comparison of reactor trip frequencies between plants which went into operation in the 1960's and the early 1970's and those which have gone into operation more recently. Trip frequency versus accumulated operating time for two plant groups are compared to see the extent to which design differences (e.g., capacity, thermal margin) affect trip frequency. This paper also presents a review of some recent events in which plant age has played a major role. The events which are reviewed have been identified through the normal systematic event analysis program conducted by the NRC. Information regarding these events was obtained through followup by reviews conducted by NRC Resident Inspectors as well as event reports submitted by licenses.

  9. PAREX, a numerical code in the service of La Hague plant operations

    Energy Technology Data Exchange (ETDEWEB)

    Bisson, J.; Huron, P.; Huel, C. [AREVA NC, La Hague Plant, Technical Direction, 50444, Beaumont-Hague (France); Dinh, B. [CEA, Centre de Marcoule, Nuclear Energy Division, Radiochemistry and Process Department, F-30207, Bagnols-sur-Ceze (France)

    2016-07-01

    The PAREX code developed by the CEA is able to simulate the PUREX process in steady or transient state. From an operator point of view, this numerical code for simulation of liquid-liquid extraction operations is an outstanding tool as an aid for plant operation through process flow sheet optimization, troubleshooting and safety analysis calculations. This paper focuses on two examples. The first concerns the evaluation of the available operating margin of the extraction zone of the first purification cycle flowsheet. The second example concerns a uranium-plutonium splitting operation where the code was used to explain a shift of plutonium concentration in the solvent outlet. (authors)

  10. Sustainable operation of a biological wastewater treatment plant

    Science.gov (United States)

    Trikoilidou, E.; Samiotis, G.; Bellos, D.; Amanatidou, E.

    2016-11-01

    The sustainable operation of a biological wastewater treatment plant is significantly linked to its removal efficiency, cost of sludge management, energy consumption and monitoring cost. The biological treatment offers high organic removal efficiency, it also entails significant sludge production, which contains active (live) and inactive (dead) microorganisms and must be treated prior to final disposal, in order to prevent adverse impact on public health and environment. The efficiency of the activated sludge treatment process is correlated to an efficient solid-liquid separation, which is strongly depended on the biomass settling properties. The most commonly encountered settling problems in a wastewater treatment plant, which are usually associated with operating conditions and specific microorganisms growth, are sludge bulking, floating sludge, pin point flocs and straggler flocs. Sustainable management of sludge and less energy consumption are the two principal aspects that determine the operational cost of wastewater treatment plants. Sludge treatment and management accumulate more than 50% of the operating cost. Aerobic wastewater treatment plants have high energy requirements for covering the needs of aeration and recirculations. In order to ensure wastewater treatment plants’ effective operation, a large number of physicochemical parameters have to be monitored, thus further increasing the operational cost. As the operational parameters are linked to microbial population, a practical way of wastewater treatment plants’ controlling is the microscopic examination of sludge, which is proved to be an important tool for evaluating plants’ performance and assessing possible problems and symptoms. This study presents a biological wastewater treatment plant with almost zero biomass production, less energy consumption and a practical way for operation control through microbial manipulation and microscopic examination.

  11. Operation of the ELETRONORTE hydrothermal systems: Amazonas, Rondonia and Amapa States and Tucurui Hydroelectric Power Plant, focusing the El Nino phenomenon; Operacao dos sistemas hidrotermicos da ELETRONORTE: Amazonas, Rondonia, Amapa e Usina Hidroeletrica de Tucurui, enfocando o fenomeno El Nino

    Energy Technology Data Exchange (ETDEWEB)

    Costalonga, Isabela dos Reis; Ferreira, Vania Maria [Centrais Eletricas do Norte do Brasil S.A. (ELETRONORTE), Brasilia, DF (Brazil)]. E-mail: ceon@eln.gov.br

    1998-07-01

    This work presents an analysis of the ELETRONORTE hydrothermal systems in the States of Amazonas, Rondonia and Amapa and the Tucurui HPP Interconnected System. The analysis ranges from the whole year of 1997 to September 1998, considering the strong influence of the El Nino phenomenon, initiated on April 1997, on the flows affluent to the reservoirs of Balbina, Samuel, Coaracy Nunes and Tucurui Hydroelectric Power Plants.

  12. Operator Training Simulator for an Industrial Bioethanol Plant

    Directory of Open Access Journals (Sweden)

    Inga Gerlach

    2016-09-01

    Full Text Available Operator training simulators (OTS are software tools for training process operators in large-scale industrial applications. Here, we describe the development, implementation and training of an OTS for a large-scale industrial plant for bioethanol production. The design of the OTS is based on conceptual analysis (previously reported by us in this journal of various configuration alternatives and training procedures at the plant. In this article, we report on how the conceptual design is used in simulation models and graphical user interfaces and how the design is applied for training of operators in the real plant environment. The results imply that OTS would be time- and cost-efficient tools for application in the biotechnological industry.

  13. Dynamic Operations Wayfinding System (DOWS) for Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Boring, Ronald Laurids [Idaho National Laboratory; Ulrich, Thomas Anthony [Idaho National Laboratory; Lew, Roger Thomas [Idaho National Laboratory

    2015-08-01

    A novel software tool is proposed to aid reactor operators in respond- ing to upset plant conditions. The purpose of the Dynamic Operations Wayfind- ing System (DOWS) is to diagnose faults, prioritize those faults, identify paths to resolve those faults, and deconflict the optimal path for the operator to fol- low. The objective of DOWS is to take the guesswork out of the best way to combine procedures to resolve compound faults, mitigate low threshold events, or respond to severe accidents. DOWS represents a uniquely flexible and dy- namic computer-based procedure system for operators.

  14. Study of operation optimization based on data mining technique in power plants

    Institute of Scientific and Technical Information of China (English)

    LI Jianqiang; LIU Jizhen; GU Junjie; NIU Chenglin

    2007-01-01

    The determination of operation optimization value is very important for economic analysis and operation optimization in power plants.The operation optimization value determined by traditional methods usually cannot reflect the actual running states correctly in power plants with the increase in running time.Based on a large amount of history data stored in power plants,a way of operation optimization by applying data mining technique is proposed.The structure of operation optimi-zation based on data mining is established and the fuzzy association rule mining algorithm is introduced to find the operation optimization target value to guide the operation in power plants.Based on the actual local data in a 300 MW unit,the operation optimization value in typical load ranges is found out by data mining to provide better adjustment guidance in industry process.Experimental results show that the determination of operation optimization value based on data mining can improve the efficiency and decrease the emission of pollutants.

  15. Operation experience of Suralaya coal-fired power plant

    Energy Technology Data Exchange (ETDEWEB)

    Saragi, M. [PT Indonesia Power (Indonesia). Suralaya Generation Business Unit

    2004-07-01

    Coal utilization for generating electricity at Suralaya coal-fired power plant has been increased from time to time. It has been driven by the growth of electricity demand from industry as well as consumption from the household sector. Generally, boilers for power plant were designed to burn the locally available coals with a limited specification range. Suralaya coal-fired power plant was built based on coal specifications from Bukit Asam (Sumatera Island), which categorized as sub-bituminous coal rank. Nowadays, supply of coal for Suralaya coal-fired power plant not only comes from Bukit Asam coal mine but also from Kalimantan coal mines. The utilization of coal from the other mines has brought other consequences on operating and equipment of the plant. It needs some effort to deal with the effect from different specifications of coal from the originated design of coal. 4 tabs.

  16. The training of operating personnel at Spanish nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, Antonio Burgos, E-mail: aburgos@tecnatom.es [TECNATOM S.A.. Escuela de Formacion Almaraz y Trillo, Madrid (Spain)

    2011-07-01

    An essential condition in order to ensure that nuclear power plants are operated reliably and safely is the availability in the Control Room of duly qualified persons capable both of preventing accidents and of responding to them should they occur. Training of the Control Room operating crews is accomplished in two major stages: a lengthy process of initial training in which the knowledge acquired at high school and university is built upon, leading to the specialisation required to appropriately carry out the tasks to be performed in the Control Room, and a continuous training program aimed at maintaining and improving the knowledge and skills required to operate the plant, with feedback of the lessons learned from the industry's operating experience. The use of full-scope simulators replicating the physical conditions and environment of the Control Room allows the period of initial training to be reduced and is the most appropriate method for the continuous training program of the control room personnel, since these simulators increase the realism of the training scenarios, help to better understand the response of the plant and provide an accurate idea of transient response times. Tecnatom is the Training Centre for Spanish Operators; it is the 'Operator Training Factory' and its mission is to train the nuclear power plant operating personnel in both technological fundamentals and the development of diagnostic skills through practical scenarios on the simulator and on-the-job training. Our training programmes are based on a SAT (Systematic Approach to Training) methodology that has been implemented at both Spanish and overseas plants. (author)

  17. Nuclear Power Plant Operator Reliability Research Based on Fuzzy Math

    Directory of Open Access Journals (Sweden)

    Fang Xiang

    2011-01-01

    Full Text Available This paper makes use of the concept and theory of fuzzy number in fuzzy mathematics, to research for the response time of operator in accident of Chinese nuclear power plant. Through the quantitative analysis for the performance shape factors (PSFs which influence the response time of operators, the formula of the operator response time is obtained based on the possibilistic fuzzy linear regression model which is used for the first time in this kind of research. The research result shows that the correct research method can be achieved through the analysis of the information from a small sample. This method breaks through the traditional research method and can be used not only for the reference to the safe operation of nuclear power plant, but also in other areas.

  18. A methodology for nuclear power plant operational events evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Jeferson, E-mail: jeferson@cnen.gov.br [Comissao Nacional de Energia Nuclear (CGRC/CNEN), Rio de janeiro, RJ (Brazil). Coordenacao Geral de Reatores e do Ciclo de Combustivel; Costa, Sergio Dias, E-mail: sergiodiascosta@hotmail.com [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Operational events are normal occurrences in industrial plants and in nuclear power plants. The evaluation of operational events gains importance when it comes specifically to nuclear power plants due to the proportions that the impact and the consequences of these events may cause to the installation itself, their workers, the external area of the nuclear installation, the environment and to the public in general. These consequences, for the operation of these facilities can range from very little, until the consequences that lead to accidents and can cause significant impacts. Operational events may be associated or have influence in many fields of knowledge, such as operation, maintenance, engineering, Radiological Protection, physical protection, chemistry, Human or Organizational Factors and external events, among others. The accident at the Fukushima Daichi nuclear power plant, shows the importance of exhausting all the studies concerning operational events in order to improve the operational safety of nuclear plants, considering all the causes and possible consequences. In this context, the evaluation of operational events discipline emerges as an important and relevant tool to contribute to the maintenance and/or improvement of the operational safety of nuclear installations. Not without reason the nuclear industry actively participates in programs of exchange of operational experience, where relevant events are thoroughly evaluated and discussed in specific forums, such as power plant operators, regulators and/or joint technical meetings, always with the purpose to prevent, minimize or mitigate its consequences. Any evaluation of operational events passes necessarily by an in-depth study of the circumstances of the event, culminating with the identification of your cause and proposition of corrective actions to prevent recurrence of similar events. Additionally, the events should not be studied individually, but evaluated within a temporal context in order

  19. Inventory of power plants in the United States, 1993

    Energy Technology Data Exchange (ETDEWEB)

    1994-12-01

    The Inventory of Power Plants in the United States is prepared annually by the Survey Management Division, Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), U.S. Department of Energy (DOE). The purpose of this publication is to provide year-end statistics about electric generating units operated by electric utilities in the United States (the 50 States and the District of Columbia). The publication also provides a 10-year outlook of future generating unit additions. Data summarized in this report are useful to a wide audience including Congress, Federal and State agencies, the electric utility industry, and the general public. Data presented in this report were assembled and published by the EIA to fulfill its data collection and dissemination responsibilities as specified in the Federal Energy Administration Act of 1974 (Public Law 93-275) as amended.

  20. Analysis of Optimal Operation of an Energy Integrated Distillation Plant

    DEFF Research Database (Denmark)

    Li, Hong Wen; Hansen, C.A.; Gani, Rafiqul

    2003-01-01

    distillation plant is investigated more closely with the purpose of elucidating essential decisions behind planning experiments, which are suitable for identifying models and constraints. The basis for analysis of optimal operation is the type of operation upon which an application focuses. In this paper...... and their influence upon the further decisions behind the experimental design. An energy-integrated distillation column, which may exhibit fold bifurcations, is used as a relevant example process....

  1. Operation of Concentrating Solar Power Plants in the Western Wind and Solar Integration Phase 2 Study

    Energy Technology Data Exchange (ETDEWEB)

    Denholm, P.; Brinkman, G.; Lew, D.; Hummon, M.

    2014-05-01

    The Western Wind and Solar Integration Study (WWSIS) explores various aspects of the challenges and impacts of integrating large amounts of wind and solar energy into the electric power system of the West. The phase 2 study (WWSIS-2) is one of the first to include dispatchable concentrating solar power (CSP) with thermal energy storage (TES) in multiple scenarios of renewable penetration and mix. As a result, it provides unique insights into CSP plant operation, grid benefits, and how CSP operation and configuration may need to change under scenarios of increased renewable penetration. Examination of the WWSIS-2 results indicates that in all scenarios, CSP plants with TES provides firm system capacity, reducing the net demand and the need for conventional thermal capacity. The plants also reduced demand during periods of short-duration, high ramping requirements that often require use of lower efficiency peaking units. Changes in CSP operation are driven largely by the presence of other solar generation, particularly PV. Use of storage by the CSP plants increases in the higher solar scenarios, with operation of the plant often shifted to later in the day. CSP operation also becomes more variable, including more frequent starts. Finally, CSP output is often very low during the day in scenarios with significant PV, which helps decrease overall renewable curtailment (over-generation). However, the configuration studied is likely not optimal for High Solar Scenario implying further analysis of CSP plant configuration is needed to understand its role in enabling high renewable scenarios in the Western United States.

  2. Information management system for design, construction and operation of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Bolch, M.C. (Duke Power Co. (US)); Jones, C.R. (S. Levy Inc. (US))

    1990-01-01

    This paper describes the principal requirements and features of a computerized information management system (IMS) believed to be a necessary part of the program to design, build and operate the next generation of nuclear power plants in the United States. This way a result of extensive review and input from an industry group studying future nuclear power plant construction improvements. The needs of the power plant constructor, owner and operator for such a computerized technical data base are described in terms of applications and scope and timing of turnover of the IMS by the plant designer. The applications cover the full life cycle of the plant including project control, construction activities, quality control, maintenance and operation. The scope of the IMS is also described in terms of the technical data to be included, hardware and software capabilities and training. The responsibilities of the plant designer for developing the IMS and generating the technical data base is defined as part of the plant process. The requirements to be met include a comprehensive plant data model and computer system hardware and software.

  3. Concrete Plant Operations Optimization Using Combined Simulation and Genetic Algorithms

    NARCIS (Netherlands)

    Cao, Ming; Lu, Ming; Zhang, Jian-Ping

    2004-01-01

    This work presents a new approach for concrete plant operations optimization by combining a ready mixed concrete (RMC) production simulation tool (called HKCONSIM) with a genetic algorithm (GA) based optimization procedure. A revamped HKCONSIM computer system can be used to automate the simulation m

  4. Concrete Plant Operations Optimization Using Combined Simulation and Genetic Algorithms

    NARCIS (Netherlands)

    Cao, Ming; Lu, Ming; Zhang, Jian-Ping

    2004-01-01

    This work presents a new approach for concrete plant operations optimization by combining a ready mixed concrete (RMC) production simulation tool (called HKCONSIM) with a genetic algorithm (GA) based optimization procedure. A revamped HKCONSIM computer system can be used to automate the simulation m

  5. Concrete Plant Operations Optimization Using Combined Simulation and Genetic Algorithms

    NARCIS (Netherlands)

    Cao, Ming; Lu, Ming; Zhang, Jian-Ping

    2004-01-01

    This work presents a new approach for concrete plant operations optimization by combining a ready mixed concrete (RMC) production simulation tool (called HKCONSIM) with a genetic algorithm (GA) based optimization procedure. A revamped HKCONSIM computer system can be used to automate the simulation

  6. Development, Operation, and Future Prospects for Implementing Biogas Plants

    DEFF Research Database (Denmark)

    Lybæk, Rikke

    2014-01-01

    , as is the case of biomass from nature conservation, straw, deep litter, etc. Further, the chapter discusses whether or not biogas technology can create new job opportunities in rural areas that lack development. Economic results from operating centralized biogas plants in Denmark now also stress the importance...

  7. Cyclic operation of power plant; Cyklisk drift av kraftvaermeverk

    Energy Technology Data Exchange (ETDEWEB)

    Storesund, Jan

    2007-12-15

    The great majority of power plants are designed for base load operation with a relatively small number of starts and stops per year. Therefore, there has been no need to consider fatigue at design. Over the last few years operation with more frequent starts and stops exists as a consequence of swinging electricity prices that has become common. This involves significantly higher frequency of damages; not least fatigue relates damages, and the number of severe failures in components that never before have had damage problems may increase as well. In the present work the different types of component that may suffer from cyclic operation related damage are gathered by a literature survey and described as follows: - where and how the damages comes up, - constructions that should be avoided, - non-destructive testing (NDT) for damage that may come up under cyclic operation, - calculation and assessment of integrity of critical components - areas where continued research would be valuable. Recommendations have been put together to be used to prevent cyclic operation related damage and to detect it in time. The target group for this study is i) plant owners of plants where cyclic operation is or may be present, ii) researchers in the area, and, iii) inspectors and NDT-operators. There are quite a number of components where cyclic operation has been found to significantly influence the lift time. Some of these components are described in many papers whereas occasional papers have been found for others. The amount of information that is possible to get for a certain component is likely related to its significance for cyclic operation damage. The most frequently reported problem is ligament cracking of high temperature headers. Other components where extensive studies have been done are: wall panels, creep-fatigue loaded welds and turbine components

  8. Inertial Fusion Power Plant Concept of Operations and Maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Anklam, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Knutson, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Dunne, A. M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kasper, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sheehan, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Lang, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Roberts, V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mau, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-01-15

    Parsons and LLNL scientists and engineers performed design and engineering work for power plant pre-conceptual designs based on the anticipated laser fusion demonstrations at the National Ignition Facility (NIF). Work included identifying concepts of operations and maintenance (O&M) and associated requirements relevant to fusion power plant systems analysis. A laser fusion power plant would incorporate a large process and power conversion facility with a laser system and fusion engine serving as the heat source, based in part on some of the systems and technologies advanced at NIF. Process operations would be similar in scope to those used in chemical, oil refinery, and nuclear waste processing facilities, while power conversion operations would be similar to those used in commercial thermal power plants. While some aspects of the tritium fuel cycle can be based on existing technologies, many aspects of a laser fusion power plant presents several important and unique O&M requirements that demand new solutions. For example, onsite recovery of tritium; unique remote material handling systems for use in areas with high radiation, radioactive materials, or high temperatures; a five-year fusion engine target chamber replacement cycle with other annual and multi-year cycles anticipated for major maintenance of other systems, structures, and components (SSC); and unique SSC for fusion target waste recycling streams. This paper describes fusion power plant O&M concepts and requirements, how O&M requirements could be met in design, and how basic organizational and planning issues can be addressed for a safe, reliable, economic, and feasible fusion power plant.

  9. Inertial fusion power plant concept of operations and maintenance

    Science.gov (United States)

    Knutson, Brad; Dunne, Mike; Kasper, Jack; Sheehan, Timothy; Lang, Dwight; Anklam, Tom; Roberts, Valerie; Mau, Derek

    2015-02-01

    Parsons and LLNL scientists and engineers performed design and engineering work for power plant pre-conceptual designs based on the anticipated laser fusion demonstrations at the National Ignition Facility (NIF). Work included identifying concepts of operations and maintenance (O&M) and associated requirements relevant to fusion power plant systems analysis. A laser fusion power plant would incorporate a large process and power conversion facility with a laser system and fusion engine serving as the heat source, based in part on some of the systems and technologies advanced at NIF. Process operations would be similar in scope to those used in chemical, oil refinery, and nuclear waste processing facilities, while power conversion operations would be similar to those used in commercial thermal power plants. While some aspects of the tritium fuel cycle can be based on existing technologies, many aspects of a laser fusion power plant presents several important and unique O&M requirements that demand new solutions. For example, onsite recovery of tritium; unique remote material handling systems for use in areas with high radiation, radioactive materials, or high temperatures; a five-year fusion engine target chamber replacement cycle with other annual and multi-year cycles anticipated for major maintenance of other systems, structures, and components (SSC); and unique SSC for fusion target waste recycling streams. This paper describes fusion power plant O&M concepts and requirements, how O&M requirements could be met in design, and how basic organizational and planning issues can be addressed for a safe, reliable, economic, and feasible fusion power plant.

  10. OPERATION OF THE HOUSEHOLD SEWAGE TREATMENT PLANTS IN POLAND

    Directory of Open Access Journals (Sweden)

    Marcelina Pryszcz

    2015-01-01

    Full Text Available In many rural communities the building of sewage collection and treatment system is still current and important problem of water and wastewater management. Besides the collection of sewage in the septic tank, the solution for wastewater treatment from individual buildings without access to sewerage system is the construction of household sewage treatment plants. Construction of household sewage treatment plant poses a number of challenges for municipalities and potential investors. The existing plants should be analyzed, so that in the future the selected systems would be characterized by high performance, simple operation and reliable exploitation. In the paper, the assessment of selection criteria of adopted technical solution and the functioning of household sewage treatment plants is carried out.

  11. A technical system to improve the operational monitoring of the Zaporozhye nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, M.; Carl, H.; Nowak, K. [Technischer Ueberwachungsverein Rheinland, Koeln (Germany). Inst. for Nuclear Engineering and Radiation Protection; Schumann, P.; Seidel, A.; Weiss, F.P.; Zschau, J.

    1998-10-01

    As part of the programme implemented by the German Ministry of Environment, Nature Conservation and Reactor Safety to cooperate with the Central and Eastern European States (CEES) and the Commonwealth of Independent States (CIS) in the area of nuclear safety, a technical system to improve operational monitoring has been designed, specified and established since 1992 as a pilot project in the Zaporozhye/Ukraine nuclear power plant by Forschungszentrum Rossendorf and Technischer Ueberwachungsverein Rheinland with a significant contribution from the State Scientific and Technical Centre of the Ukrainian supervisory authority. The technical system complements existing operational checking and monitoring facilities by including modern means of information technology. It enables a continuous monitoring of the state of unit 5 in normal operation and in cases of anomalies or incidents so that when recognisable deviations from the regular plant operation occur, the Ukrainian supervisory authority can immediately inquire and if necessary impose conditions on the operator. The radiological and meteorological parameters at the nuclear power plant location are monitored to the extent necessary to assess the current radiation situation and to implement efficient emergency management measures. (orig.)

  12. Unknown Quantum States and Operations, a Bayesian View

    CERN Document Server

    Fuchs, C; Fuchs, Christopher A.; Schack, Ruediger

    2004-01-01

    The classical de Finetti theorem provides an operational definition of the concept of an unknown probability in Bayesian probability theory, where probabilities are taken to be degrees of belief instead of objective states of nature. In this paper, we motivate and review two results that generalize de Finetti's theorem to the quantum mechanical setting: Namely a de Finetti theorem for quantum states and a de Finetti theorem for quantum operations. The quantum-state theorem, in a closely analogous fashion to the original de Finetti theorem, deals with exchangeable density-operator assignments and provides an operational definition of the concept of an "unknown quantum state" in quantum-state tomography. Similarly, the quantum-operation theorem gives an operational definition of an "unknown quantum operation" in quantum-process tomography. These results are especially important for a Bayesian interpretation of quantum mechanics, where quantum states and (at least some) quantum operations are taken to be states ...

  13. Improvement of operational efficiency based on fast startup plant concepts

    Energy Technology Data Exchange (ETDEWEB)

    Grumann, Ulrich; Kurz, Harald; Meinecke, Gero; Pickard, Andreas

    2010-09-15

    The power generation sector is currently confronted with new challenges relating to the conservation of dwindling fuel reserves. At the same time we must reduce CO2 emissions in order to counteract global warming. This paper shows that power plant operation, which employs shutdowns during periods of low load demand coupled with the optimization of startup procedures are a key to reducing CO2 emissions and to conserving resources. The startup technology developed by Siemens also offers grid support in the event of naturally occurring failures of renewable energy sources. Additionally, plant profitability is improved due to the resulting savings in fuel.

  14. Summary of operating experience in Swiss nuclear power plants 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    In 1994 the Swiss nuclear power plants produced their highest-ever combined annual output. Their contribution to total electricity generation in the country was 36%. At Muehleberg the power uprate, undertaken in 1993, was effective for the first time for an entire year. The larger capacity of the new steam generators installed in 1993 in unit 1 of the Beznau NPP allows for an electric output of 103% of nominal power. The plant efficiency of the Goesgen and Leibstadt units was increased by replacing the low pressure turbines by the new ones with a modern design. The application for a power uprate of the Leibstadt reactor is still pending. For the first time in Switzerland, one of the reactor units, Beznau 2, operated on an extended cycle of one and a half years, with no refuelling outage in 1994. In spite of the replacements of two of its three low pressure turbines, Goesgen had the shortest refuelling shutdown since the start of commercial operation. The average number of reactor scrams at the Swiss plants remained stable, at less than one scram per reactor year. Re-inspection of crack indications detected in 1990 in the core shroud of the Muehleberg reactor revealed no significant changes. A crack indication was found in one of the other welds inspected. The Swiss government issued a limited operating licence for Beznau 2 for the next ten years, i.e. until the end of 2004. The only other unit with a limited operating licence (until 2003) is Muehleberg. The remaining three reactor units, have no time limits on their operating licences, in accordance with the Atomic Law. Goesgen is the first Swiss nuclear power plant having now produced more than 100 billion kWh. As from January 1, 1995, the nominal net power of the largest Swiss reactor unit, Leibstadt, has been fixed at 1030 MW; that of the Goesgen NPP has been increased by 25 MW to 965 MW. (author) figs., tabs.

  15. 78 FR 65389 - United States Enrichment Corporation, Paducah Gaseous Diffusion Plant

    Science.gov (United States)

    2013-10-31

    ... COMMISSION United States Enrichment Corporation, Paducah Gaseous Diffusion Plant AGENCY: Nuclear Regulatory...) for the Paducah Gaseous Diffusion Plant (PGDP). The current CoC for PGDP is set to expire on December... operation of a uranium enrichment facility in Paducah, Kentucky, using the gaseous ] diffusion......

  16. UNITED STATES SPECIAL OPERATIONS FORCES IN AFRICA

    Science.gov (United States)

    2016-02-16

    and Nathan Rickard ,”Operation Serval: French Intervention in Mali,” Air Operations Division, Defence Science & Technology Organisation, http...www.cfr.org/nigeria/boko-haram/p25739. 56 James J. F. Forest, Confronting the Terrorism of Boko Haram in Nigeria, Joint Special Operations University...Best Practices.” Joint Forces Quarterly, Issue 50, 3d Quarter 2008. 30 Forest, James J. F. Confronting the Terrorism of Boko Haram in

  17. The Operator's Diagnosis Task under Abnormal Operating Conditions in Industrial Process Plant

    DEFF Research Database (Denmark)

    Goodstein, L.P.; Pedersen, O.M.; Rasmussen, Jens

    1974-01-01

    Analysis of serious accidents in connection with the operation of technical installations demonstrate that the diagnosis task which confronts personnel under non-normal plant conditions is a critical one. This report presents a preliminary outline of characteristic traits connected with the task...

  18. Inventory of Power Plants in the United States, October 1992

    Energy Technology Data Exchange (ETDEWEB)

    1993-10-27

    The Inventory of Power Plants in the United States is prepared annually by the Survey Management Division, Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), US Department of Energy (DOE). The purpose of this publication is to provide year-end statistics about electric generating units operated by electric utilities in the United States (the 50 States and the District of Columbia). The publication also provides a 10-year outlook of future generating unit additions. Data summarized in this report are useful to a wide audience including Congress, Federal and State agencies, the electric utility industry, and the general public. Data presented in this report were assembled and published by the EIA to fulfill its data collection and dissemination responsibilities as specified in the Federal Energy Administration Act of 1974 (Public Law 93-275) as amended. The report is organized into the following chapters: Year in Review, Operable Electric Generating Units, and Projected Electric Generating Unit Additions. Statistics presented in these chapters reflect the status of electric generating units as of December 31, 1992.

  19. Inventory of power plants in the United States 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-18

    The Inventory of Power Plants in the US provides year-end statistics on generating units operated by electric utilities in the US (the 50 States and the District of Columbia). Statistics presented in this report reflect the status of generating units as of December 31, 1994. The publication also provides a 10-year outlook for generating unit additions. This report is prepared annually by the Coal and Electric Data and Renewables Division; Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); US Department of Energy (DOE). Data summarized in this report are useful to a wide audience including Congress, Federal, and State agencies; the electric utility industry; and the general public. This is a report of electric utility data; in cases where summary data of nonutility capacity are presented, it is specifically noted as such.

  20. Representing Operational Knowledge of PWR Plant by Using Multilevel Flow Modelling

    DEFF Research Database (Denmark)

    Zhang, Xinxin; Lind, Morten; Jørgensen, Sten Bay

    2014-01-01

    situation and support operational decisions. This paper will provide a general MFM model of the primary side in a standard Westinghouse Pressurized Water Reactor ( PWR ) system including sub - systems of Reactor Coolant System, Rod Control System, Chemical and Volume Control System, emergency heat removal......The aim of this paper is to explore the capability of representing operational knowledge by using Multilevel Flow Modelling ( MFM ) methodology. The paper demonstrate s how the operational knowledge can be inserted into the MFM models and be used to evaluate the plant state, identify the current...... systems. And the sub - systems’ functions will be decomposed into sub - models according to different operational situations. An operational model will be developed based on the operating procedure by using MFM symbols and this model can be used to implement coordination rules for organize the utilizati...

  1. On Fermionic Entangled State Representation and Fermionic Entangled Wigner Operator

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    By analogy with the bosonic bipartite entangled state we construct fermionic entangled state with the Grassmann numbers. The Wigner operator in the fermionic entangled state representation is introduced, whose marginal distributions are understood in an entangled way. The technique of integration within an ordered product (IWOP) of Fermi operators is used in our discussion.

  2. 75 FR 14638 - FirstEnergy Nuclear Operating Company; Perry Nuclear Power Plant; Environmental Assessment and...

    Science.gov (United States)

    2010-03-26

    ... COMMISSION FirstEnergy Nuclear Operating Company; Perry Nuclear Power Plant; Environmental Assessment and...Energy Nuclear Operating Company (FENOC, the licensee), for operation of the Perry Nuclear Power Plant... Manager, Plant Licensing Branch III-2, Division of Operating Reactor Licensing, Office of Nuclear...

  3. State-independent purity and fidelity of quantum operations

    Science.gov (United States)

    Kong, Fan-Zhen; Zong, Xiao-Lan; Yang, Ming; Cao, Zhuo-Liang

    2016-04-01

    The purity and fidelity of quantum operations are of great importance in characterizing the quality of quantum operations. The currently available definitions of the purity and fidelity of quantum operations are based on the average over all possible input pure quantum states, i.e. they are state-dependent (SD). In this paper, without resorting to quantum states, we define the state-independent (SI) purity and fidelity of a general quantum operation (evolution) in virtue of a new density matrix formalism for quantum operations, which is extended from the quantum state level to quantum operation level. The SI purity and fidelity gain more intrinsic physical properties of quantum operations than state-dependent ones, such as the purity of a one-qubit amplitude damping channel (with damping rate 1) is 1/2, which is in line with the fact that the channel is still a nonunitary operation described by two Kraus operators rather than a unitary one. But the state-dependent Haar average purity is 1 in this case. So the SI purity and fidelity proposed here can help the experimentalists to exactly quantify the implementation quality of an operation. As a byproduct, a new measure of the operator entanglement is proposed for a quantum evolution (unitary or nonunitary) in terms of the linear entropy of its density matrix on the orthonormal operator bases (OOBs) in Hilbert-Schmidt space.

  4. Power system operations: State estimation distributed processing

    Science.gov (United States)

    Ebrahimian, Mohammad Reza

    We present an application of a robust and fast parallel algorithm to power system state estimation with minimal amount of modifications to existing state estimators presently in place using the Auxiliary Problem Principle. We demonstrate its effectiveness on IEEE test systems, the Electric Reliability Counsel of Texas (ERCOT), and the Southwest Power Pool (SPP) systems. Since state estimation formulation may lead to an ill-conditioned system, we provide analytical explanations of the effects of mixtures of measurements on the condition of the state estimation information matrix. We demonstrate the closeness of the analytical equations to condition of several test case systems including IEEE RTS-96 and IEEE 118 bus systems. The research on the condition of the state estimation problem covers the centralized as well as distributed state estimation.

  5. Nevada Renewable Energy Training Project: Geothermal Power Plant Operators

    Energy Technology Data Exchange (ETDEWEB)

    Jim, Nichols [Truckee Meadows Community College, Reno, NV (United States)

    2014-04-29

    The purpose of this project was to develop and institute a training program for certified geothermal power plant operators (GPO). An advisory board consisting of subject matter experts from the geothermal energy industry and academia identified the critical skill sets required for this profession. A 34-credit Certificate of Achievement (COA), Geothermal Power Plant Operator, was developed using eight existing courses and developing five new courses. Approval from the Nevada System of Higher Education Board of Regents was obtained. A 2,400 sq. ft. geothermal/fluid mechanics laboratory and a 3,000 sq. ft. outdoor demonstration laboratory were constructed for hands-on training. Students also participated in field trips to geothermal power plants in the region. The majority of students were able to complete the program in 2-3 semesters, depending on their level of math proficiency. Additionally the COA allowed students to continue to an Associate of Applied Science (AAS), Energy Technologies with an emphasis in Geothermal Energy (26 additional credits), if they desired. The COA and AAS are stackable degrees, which provide students with an ongoing career pathway. Articulation agreements with other NSHE institutions provide students with additional opportunities to pursue a Bachelor of Applied Science in Management or Instrumentation. Job placement for COA graduates has been excellent.

  6. Cognitive skill training for nuclear power plant operational decision making

    Energy Technology Data Exchange (ETDEWEB)

    Mumaw, R.J.; Swatzler, D.; Roth, E.M. [Westinghouse Electric Corp., Pittsburgh, PA (United States); Thomas, W.A. [Quantum Technologies, Inc., Oak Brook, IL (United States)

    1994-06-01

    Training for operator and other technical positions in the commercial nuclear power industry traditionally has focused on mastery of the formal procedures used to control plant systems and processes. However, decisionmaking tasks required of nuclear power plant operators involve cognitive skills (e.g., situation assessment, planning). Cognitive skills are needed in situations where formal procedures may not exist or may not be as prescriptive, as is the case in severe accident management (SAM). The Westinghouse research team investigated the potential cognitive demands of SAM on the control room operators and Technical Support Center staff who would be most involved in the selection and execution of severe accident control actions. A model of decision making, organized around six general cognitive processes, was developed to identify the types of cognitive skills that may be needed for effective performance. Also, twelve SAM scenarios were developed to reveal specific decision-making difficulties. Following the identification of relevant cognitive skills, 19 approaches for training individual and team cognitive skills were identified. A review of these approaches resulted in the identification of general characteristics that are important in effective training of cognitive skills.

  7. Business Intelligence Solutions for Wind Power Plants Operation

    Directory of Open Access Journals (Sweden)

    Simona-Vasilica OPREA

    2014-01-01

    Full Text Available The European Union energy strategies imply significant changes in the power systems. These should contribute to sustainable development and protection of the environment by enabling the EU to achieve its targets set in the third package of legislative proposals for electricity and gas markets. Renewable energy sources (RES in Romania have been encouraged since 2007 and this lead to a large volume of projects. It took several years to have the first MW installed in wind power plants (WPP. Nowadays, the installed wind power in Romania is about 2642 MW, most of them (about 85% being concentrated in the south-eastern part of the country. Based on recorded data during four years in Romania, a couple of analyses have been performed. They contribute to a better integration of wind energy into power systems. This paper will describe how business intelligence solutions are applied on data regarding wind power plants operation and main conclusions that could be drawn.

  8. Budgeting for Solar PV Plant Operations & Maintenance: Practices and Pricing.

    Energy Technology Data Exchange (ETDEWEB)

    Enbar, Nadav [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Weng, Dean [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    With rising grid interconnections of solar photovoltaic (PV) systems, greater attention is being trained on lifecycle performance, reliability, and project economics. Expected to meet production thresholds over a 20-30 year timeframe, PV plants require a steady diet of operations and maintenance (O&M) oversight to meet contractual terms. However, industry best practices are only just beginning to emerge, and O&M budgets—given the arrangement of the solar project value chain—appear to vary widely. Based on insights from in-depth interviews and survey research, this paper presents an overview of the utility-scale PV O&M budgeting process along with guiding rationales, before detailing perspectives on current plant upkeep activities and price points largely in the U.S. It concludes by pondering potential opportunities for improving upon existing O&M budgeting approaches in ways that can benefit the industry at-large.

  9. Budgeting for Solar PV Plant Operations & Maintenance: Practices and Pricing.

    Energy Technology Data Exchange (ETDEWEB)

    Enbar, Nadav [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Weng, Dean [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    With rising grid interconnections of solar photovoltaic (PV) systems, greater attention is being trained on lifecycle performance, reliability, and project economics. Expected to meet production thresholds over a 20-30 year timeframe, PV plants require a steady diet of operations and maintenance (O&M) oversight to meet contractual terms. However, industry best practices are only just beginning to emerge, and O&M budgets—given the arrangement of the solar project value chain—appear to vary widely. Based on insights from in-depth interviews and survey research, this paper presents an overview of the utility-scale PV O&M budgeting process along with guiding rationales, before detailing perspectives on current plant upkeep activities and price points largely in the U.S. It concludes by pondering potential opportunities for improving upon existing O&M budgeting approaches in ways that can benefi t the industry at-large.

  10. Two years of operation of a large solar cooling plant

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M.; Romagnoni, P. (Padua Univ. (Italy)); Casasola, L. (CERIT, Pordenone (Italy))

    1993-05-01

    A solar plant was installed with a surface area of 440 m[sup 2] of evacuated-tube collectors, a reflecting surface of the same area and an absorption refrigeration system for air-conditioning the CERIT building of Pordenone. A 43 m[sup 3] heat-storage unit, at temperatures of 80-90[sup o]C, and a 150 m[sup 3] cold-storage unit were also installed. These components form the largest solar cooling plant in Europe. After two years of operation, it is possible to evaluate the project as a whole, and to appreciate the contribution of the flat solar reflector and the working of the absorption unit. (Author)

  11. Operating experience from Swedish nuclear power plants 2002

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    The total production of electricity from Swedish nuclear power plants was 65.6 TWh during 2002, which is a decrease compared to 2001. The energy capability factor for the 11 Swedish reactors averaged 80.8%. The PWRs at Ringhals averaged 87.6%, while the BWRs, not counting Oskarshamn 1, reached 89.2%. No events, which in accordance to conventions should be reported to IAEA, have occurred during 2002. Operational statistics are presented for each Swedish reactor. The hydroelectric power was 66 TWh, 16% lower than 2000. Wind power contributed 0.5 TWh, and remaining production sources, mainly from solid fuel plants combined with district heating, contributed 10.9 TWh. The electricity generation totalled 143 TWh, considerably less than the record high 2001 figure of 158.7 TWh. The preliminary figures for export were 14.8 TWh and and for import 20.1 TWh.

  12. Uncertainties in the daily operation of a district heating plant

    DEFF Research Database (Denmark)

    Sorknæs, Peter

    Studies have found that district heating (DH) systems should play an important role in future sustainable energy systems, but that DH has to adapt to lower heat demands. This means adapting to reduced operation hours for units essential for DHs integration in other parts of the energy system...... Ringkøbing District Heating is used as a case to investigate what costs market uncertainties can incur on a DH plant. It is found that the market uncertainties in a 4 months simulated period increased Ringkøbing District Heatings costs by less than 1%. Several factors are however not included in this paper....

  13. Leak before break application in French PWR plants under operation

    Energy Technology Data Exchange (ETDEWEB)

    Faidy, C. [EDF SEPTEN, Villeurbanne (France)

    1997-04-01

    Practical applications of the leak-before break concept are presently limited in French Pressurized Water Reactors (PWR) compared to Fast Breeder Reactors. Neithertheless, different fracture mechanic demonstrations have been done on different primary, auxiliary and secondary PWR piping systems based on similar requirements that the American NUREG 1061 specifications. The consequences of the success in different demonstrations are still in discussion to be included in the global safety assessment of the plants, such as the consequences on in-service inspections, leak detection systems, support optimization,.... A large research and development program, realized in different co-operative agreements, completes the general approach.

  14. 77 FR 3009 - Knowledge and Abilities Catalog for Nuclear Power Plant Operators: Advanced Boiling Water Reactors

    Science.gov (United States)

    2012-01-20

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Knowledge and Abilities Catalog for Nuclear Power Plant Operators: Advanced Boiling Water Reactors..., ``Knowledge and Abilities Catalog for Nuclear Power Plant Operators: Advanced Boiling Water Reactors.''...

  15. Power plant technology 2014. Strategies, systems engineering and operation; Kraftwerkstechnik 2014. Strategien, Anlagentechnik und Betrieb

    Energy Technology Data Exchange (ETDEWEB)

    Beckmann, Michael; Hurtado, Antonio

    2014-07-01

    The book on power plant technology 2014 (strategies, systems engineering and operation) covers the following issues: Climate, politics and economy; wind power; fossil-fuel power plants, flexible power plants - plant operation, flexible power plants- materials, materials for energy technology, fuel feed and incineration, modeling of the water-vapor-circuit, corrosion, deposits and cleaning, vapor turbines, GUD power plants, fluidized bed combustion, energetic biomass use, combined heat and power generation and decentralized units, storage facilities, emissions - mitigation and measuring techniques.

  16. New optical field operator expansion in number state representation

    Institute of Scientific and Technical Information of China (English)

    Yang Yang; Fan Hong-Yi

    2013-01-01

    By virtue of the Weyl ordering method,we find a new formalism of optical field operator expansion in number state representation.Miscellaneous optical fields' (coherent state,squeezed field,Wigner operator,etc.) new expansions are therefore exhibited.Some new generating functions of special polynomials are derived herewith.

  17. 75 FR 16524 - FirstEnergy Nuclear Operating Company, Perry Nuclear Power Plant; Exemption

    Science.gov (United States)

    2010-04-01

    ... COMMISSION FirstEnergy Nuclear Operating Company, Perry Nuclear Power Plant; Exemption 1.0 Background First.... NFP-58, which authorizes operation of the Perry Nuclear Power Plant, Unit 1 (PNPP). The license... rule's compliance date for all operating nuclear power plants, but noted that the...

  18. Unknowability of Quantum State forbids perfectly quantum operations

    Institute of Scientific and Technical Information of China (English)

    CAIQing-yu; LIBai-wen

    2004-01-01

    We analyze the oonnection between quantum operations and accessible information. And we find that the accessible information decreases under quantum operations. We show that it is impossible to perfectly manipulate an unknown state in an open quantum system. That the accessible information decreases under quantum operations gives a fundamental limitation in the microscopic world.

  19. Unknowability of Quantum State forbids perfectly quantum operations

    Institute of Scientific and Technical Information of China (English)

    CAI Qing-yu; LI Bai-wen

    2004-01-01

    We analyze the connection between quantum operations and accessible information. And we find that the accessible information decreases under quantum operations. We show that it is impossible to perfectly manipulate an unknown state in an open quantum system. That the accessible information decreases under quantum operations gives a fundamental limitation in the microscopic world.

  20. Entangled State Representation for Hamiltonian Operator of Quantum Pendulum

    Institute of Scientific and Technical Information of China (English)

    FANHong-Yi

    2003-01-01

    By virtue of the Einstein-Podolsky-Rosen entangled state, which is the common eigenvector of two panicles' relative coordinate and total momentum, we establish the bosonic operator version of the Hamiltonian for a quantum point-mass pendulum. The Hamiltonian displays the correct Schroedlnger equation in the entangled state representation.The corresponding Heisenberg operator equations which predict the angular momentum-angle uncertainty relation are derived. The quantum operator description of two quantum pendulums coupled by a spring is also derived.

  1. Entangled State Representation for Hamiltonian Operator of Quantum Pendulum

    Institute of Scientific and Technical Information of China (English)

    FAN Hong-Yi

    2003-01-01

    By virtue of the Einstein-Podolsky-Rosen entangled state, which is the common eigenvector of two particles'relativecoordinate and total momentum, we establish the bosonic operator version of the Hamiltonian for a quantumpoint-mass pendulum. The Hamiltonian displays the correct Schrodinger equation in the entangled state representation.The corresponding Heisenberg operator equations which predict the angular momentum-angle uncertainty relation arederived. The quantum operator description of two quantum pendulums coupled by a spring is also derived.

  2. Operating experience 1993 in Swedish nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    For many years, the Swedish nuclear power plants had a very good track record, compared with the international average. This trend was broken in 1993. During the year, six power plants were shut down for extended periods of time, for different safety-related reasons. During the autumn, a reactor containment leak was detected during scheduled containment leak rate testing at Barsebaeck 2. The unit was shut down for extensive investigation and corrective action for the rest of the year. Ringhals 2 was shut down last six months of the year as crack indications were found in a weld next to a control rod penetration in the reactor vessel head. Extensive tests and analyses revealed that the crack originated from the manufacturing of the vessel head and was of minor importance to safety. Oskarshamn 1 was shut down the whole year. Cracks in cold bent pipes in the residual heat removal system and cracks in the feedwater riser pipes lead to extensive replacement of piping, including pipes inside the reactor vessel. Decontamination of the reactor vessel was successful and attracted world wide interest. A programme for plant status verification was started in order to establish long-term operating conditions. Replacement of the pipe insulation and the inlet strainers in the core and containment spray systems solved the problems with clogging at certain failures in Barsebaeck, Ringhals 1 and Oskarshamn 1 and 2. Six of the reactors had an extremely high availability, of about 90 per cent and more. By year end, eleven of the twelve reactors were in full power operation.

  3. Personality Factors and Nuclear Power Plant Operators: Initial License Success

    Science.gov (United States)

    DeVita-Cochrane, Cynthia

    Commercial nuclear power utilities are under pressure to effectively recruit and retain licensed reactor operators in light of poor candidate training completion rates and recent candidate failures on the Nuclear Regulatory Commission (NRC) license exam. One candidate failure can cost a utility over $400,000, making the successful licensing of new operators a critical path to operational excellence. This study was designed to discover if the NEO-PI-3, a 5-factor measure of personality, could improve selection in nuclear utilities by identifying personality factors that predict license candidate success. Two large U.S. commercial nuclear power corporations provided potential participant contact information and candidate results on the 2014 NRC exam from their nuclear power units nation-wide. License candidates who participated (n = 75) completed the NEO-PI-3 personality test and results were compared to 3 outcomes on the NRC exam: written exam, simulated operating exam, and overall exam result. Significant correlations were found between several personality factors and both written and operating exam outcomes on the NRC exam. Further, a regression analysis indicated that personality factors, particularly Conscientiousness, predicted simulated operating exam scores. The results of this study may be used to support the use of the NEO-PI-3 to improve operator selection as an addition to the current selection protocol. Positive social change implications from this study include support for the use of a personality measure by utilities to improve their return-on-investment in candidates and by individual candidates to avoid career failures. The results of this study may also positively impact the public by supporting the safe and reliable operation of commercial nuclear power utilities in the United States.

  4. Operating Experience from two new Biomass Fired FBC-Plants

    Energy Technology Data Exchange (ETDEWEB)

    Bolhar-Nordenkampf, M.; Tschanun, I.; Kaiser, S. [Austrian Energy and Environment AG, Vienna (Austria)

    2006-07-15

    The use of renewable fuels in industrial power plants is rising continuously. The driving forces are the Kyoto protocol for CO{sub 2} reduction resulting in government support for green power electricity, substitution of imported primary energy and multi-fuel concepts together with RDF. Biomass fuel exists in various forms, traditionally as wood, bark, harvesting residues sewage sludge and organic waste. A favourable combustion technology is Austrian Energy's 'ECOFLUID' bubbling fluidized bed. Advantageous is the principle of a substoichiometric bed operation which allows bed temperature control in the range between 650 deg C - 850 deg C. Therefore, also fuel with low ash melting temperature can be burned. The applied staged combustion concept results in a homogenous temperature profile in the furnace and first pass of the boiler and thus low NO{sub x} emission. One new plant, owned by Energie AG in Timelkam/Austria has been commissioned in winter 2005. The main fuel of this 57 t/h boiler is bark, wood residues and waste wood up to 30% of the total thermal capacity. Grinding dust and saw dust can be co-fired, too. Optionally, sludge and animal wastes can be fired. The boiler is designed for 42 barg at live steam temperature of 440 deg C. The other new 30 MW{sub th} plant, owned by M-real Hallein AG in Hallein/Austria has been commissioned in winter 2005, too. The boiler is fired with wood chips, bark, rejects and other paper mill residues and furthermore it is able to burn the sludge of the mills own waste water treatment plant. Beside the boiler works as a post combustion system for exhaust gases from a 1 MW Biogas Otto-Engine, or alternatively it is able to burn the biogas directly. The boiler is designed for 61 barg at live steam temperature of 450 deg C.

  5. An analysis of the impacts of economic incentive programs on commercial nuclear power plant operations and maintenance costs

    Energy Technology Data Exchange (ETDEWEB)

    Kavanaugh, D.C.; Monroe, W.H. [Pacific Northwest Lab., Richland, WA (United States); Wood, R.S. [Nuclear Regulatory Commission, Washington, DC (United States)

    1996-02-01

    Operations and Maintenance (O and M) expenditures by nuclear power plant owner/operators possess a very logical and vital link in considerations relating to plant safety and reliability. Since the determinants of O and M outlays are considerable and varied, the potential linkages to plant safety, both directly and indirectly, can likewise be substantial. One significant issue before the US Nuclear Regulatory Commission is the impact, if any, on O and M spending from state programs that attempt to improve plant operating performance, and how and to what extent these programs may affect plant safety and pose public health risks. The purpose of this study is to examine the role and degree of impacts from state promulgated economic incentive programs (EIPs) on plant O and M spending. A multivariate regression framework is specified, and the model is estimated on industry data over a five-year period, 1986--1990. Explanatory variables for the O and M spending model include plant characteristics, regulatory effects, financial strength factors, replacement power costs, and the performance incentive programs. EIPs are found to have statistically significant effects on plant O and M outlays, albeit small in relation to other factors. Moreover, the results indicate that the relatively financially weaker firms are more sensitive in their O and M spending to the presence of such programs. Formulations for linking spending behavior and EIPs with plant safety performance remains for future analysis.

  6. Analysis of operational methane emissions from pressure relief valves from biogas storages of biogas plants.

    Science.gov (United States)

    Reinelt, Torsten; Liebetrau, Jan; Nelles, Michael

    2016-10-01

    The study presents the development of a method for the long term monitoring of methane emissions from pressure relief valves (PRV(1)) of biogas storages, which has been verified during test series at two PRVs of two agricultural biogas plants located in Germany. The determined methane emission factors are 0.12gCH4kWhel(-1) (0.06% CH4-loss, within 106days, 161 triggering events, winter season) from biogas plant A and 6.80/7.44gCH4kWhel(-1) (3.60/3.88% CH4-loss, within 66days, 452 triggering events, summer season) from biogas plant B. Besides the operational state of the biogas plant (e.g. malfunction of the combined heat and power unit), the mode of operation of the biogas flare, which can be manually or automatically operated as well as the atmospheric conditions (e.g. drop of the atmospheric pressure) can also affect the biogas emission from PRVs.

  7. Dynamic operational risk management at industrial irradiation plants

    Energy Technology Data Exchange (ETDEWEB)

    Wieland, Patricia, E-mail: pwieland@cnen.gov.b [Brazilian National Nuclear Energy Commission (CNEN), Rio de Janeiro, RJ (Brazil); Lustosa, Leonardo J. [Pontifical Catholic Univ. (PUC-Rio), Rio de Janeiro, RJ (Brazil)

    2010-03-15

    Although feasibility studies indicate that industrial irradiation can be sound business, some initiatives fail in few years. In Brazil, the operation of some industrial irradiation plants has been discontinued in spite of the growing export market for tropical fruits like mangoes and papayas, of which Brazil is one of the major producers. This paper discusses the overall aspects of the food irradiation in Brazil, singles out dynamic operation risk management as an important need and provides suggestions for further developments. This research work involves literature review as well as interviews with irradiation industry stake holders in order to identify the ORs and to assess the situation in a logical and integrated way. The results show that public acceptance is not a major issue for the food preservation industry in Brazil. On the contrary, evidences show that there is public support, provided that information on the subject is disseminated among consumers. Need for improvements have been detected in the areas of industrial operational risk management, external relations for export, and regulatory issues, among others to support decision making in establishing and developing industrial food irradiation capabilities to serve Brazilian tropical fruit exports. (author)

  8. Operating experience from Swedish nuclear power plants, 1999

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The total generation of electricity from Swedish nuclear power plants was 70.1 TWh during 1999, which is slightly more than the mean value for the last five years. The total electricity consumption decreased by one percent, compared with 1998, to a total of 142.3 TWh, due to an unusually warm summer and autumn. The abundant supply of hydroelectric power resulted in comparatively extensive load-following operation by the nuclear plants during the year. Production losses due to low demand totalled 3.0 TWh. The closure of Barsebaeck 1 will result in a capacity reduction exceeding 4 TWh per year. The hydroelectric power production was 70 TWh, which was 6 TWh more than during a normal year, i.e. a year with average rainfall. The remaining production sources, mainly from solid fuel plants combined with district heating contributed 9 TWh. Electricity generation by means of wind power is still increasing. There are now about 470 wind power stations, which produced 0.3 TWh during the year. The total electricity generation totalled 149.8 TWh, a three percent decrease compared with 1998. The preliminary figures for export were 15.9 TWh and for import 8.4 TWh. The figures above are calculated from the preliminary production result. A comprehensive report on electric power supply and consumption in Sweden is provided in the 1999 Annual Report from the Swedish Power Association. The unit capability factor for the PWRs at Ringhals averaged 91%, while the BWRs averaged 82% mainly due to the extended outages. The BWR reactors at Forsmark averaged as much as 93%. Forsmark 1 experienced the shortest refuelling outage ever in Sweden, only 9 days and 20 hours. In May, Oskarshamn 2 passed a historical milestone - the unit produced 100 TWh since connection to the grid in 1974. The final production day for Barsebaeck 1, which had been in commercial operation since 1975, was on November 30 when a decision by the Swedish Government revoked the operating licence. Three safety-related events

  9. Operation and maintenance results from ISFOC CPV plants

    Science.gov (United States)

    Gil, Eduardo; Martinez, María; de la Rubia, Oscar

    2017-09-01

    The analysis of field operation and maintenance data collected during a period of over eight years, from CPV installations consisting of three different CPV technologies (including second generation of one of these technologies), has allowed us to get valuable information about the long-term degradation of the CPV systems. Through the study of the maintenance control ratio previously defined and by applying the root cause analysis methodology, the components responsible for the most unplanned interventions for each technology were identified. Focusing maintenance efforts on these components, a reduction of the unplanned interventions and the total cost of maintenance has been achieved over the years. Therefore, the deployment of an effective maintenance plan, identifying critical components, is essential to minimize the risk for investors and maximize the CPV power plants lifetime and energy output, increasing the availability of CPV installations, boosting market confidence in CPV systems.

  10. Bioluminescence for determining energy state of plants

    Science.gov (United States)

    Ching, T. M.

    1975-01-01

    Bioluminescence produced by the luciferin-luciferase system is a very sensitive assay for ATP content in extracts of plant materials. The ATP test for seed and pollen viability and vigor is presented, along with prediction of high growth potential and productivity in new crosses and selections of breeding materials. ATP as an indicator for environmental quality, stresses, and metabolic regulation is also considered.

  11. Sand and Gravel Operations in the United States - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer includes sand and gravel operations in the United States. These data were obtained from information reported voluntarily to the USGS by the aggregate...

  12. Crushed Stone Operations in the United States - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer includes crushed stone operations in the United States. These data were obtained from information reported voluntarily to the USGS by the aggregate...

  13. Plant breeding and rural development in the United States.

    Science.gov (United States)

    KE Woeste; SB Blanche; KA Moldenhauer; CD Nelson

    2010-01-01

    Plant breeders contributed enormously to the agricultural and economic development of the United States. By improving the profitability of farming, plant breeders improved the economic condition of farmers and contributed to the growth and structure of rural communities. In the years since World War II, agriculture and the quality of rural life have been driven by...

  14. Plant and Animal Phenology Data for the United States

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — As of January 1, 2013, the dataset contains phenology data on 591 species of plants and animals, with 7,512 locations registered across the United States. Protocols...

  15. State of Washington Aquatic Plant Management Program

    Science.gov (United States)

    1979-10-01

    the east coast until 1954 when it began rapid growth and expansion ( Stevenson and Confer, 1978). It became a serious problem in Chesapeake Bay and...milfoil infestation and indicates that there is some flexibility in waterfowl feeding habits. Stevenson and Confer (1978), in an analysis of species...and a comparative absence of humus , detritus, and plankton. Besides the lack of suitable substrate, vascular plants have a complexity of organization

  16. Positive finite rank elementary operators and characterizing entanglement of states

    CERN Document Server

    Qi, Xiaofei

    2010-01-01

    In this paper, a class of indecomposable positive finite rank elementary operators are constructed. This allows us to give a simple necessary and sufficient criterion for separability of pure states in bipartite systems of any dimension in terms of two low rank positive elementary operators and get some new mixed entangled states that can not be detected by the positive partial transpose (PPT) criterion and the realignment criterion.

  17. Positive finite rank elementary operators and characterizing entanglement of states

    Energy Technology Data Exchange (ETDEWEB)

    Qi Xiaofei [Department of Mathematics, Shanxi University, Taiyuan 030006 (China); Hou Jinchuan, E-mail: qixf1980@126.com, E-mail: jinchuanhou@yahoo.com.cn [Department of Mathematics, Taiyuan University of Technology, Taiyuan 030024 (China)

    2011-05-27

    In this paper, some indecomposable positive finite rank elementary operators of order (n, n) are constructed. This allows us to give a simple necessary and sufficient criterion for the separability of pure states in bipartite systems of any dimension in terms of positive elementary operators of order (2, 2) and obtain some new mixed entangled states that cannot be detected by the positive partial transpose criterion and the realignment criterion.

  18. Pilot plant operation of the Uranium Chip Oxidation Facility at the Y-12 Plant

    Energy Technology Data Exchange (ETDEWEB)

    Childs, Y.C.

    1987-01-16

    Due to changing environmental regulations, the current practice of depleted uranium chip (machine turning) disposal via shallow land burial has become environmentally objectionable. The chips are pyrophoric and oxidize rapidly when exposed to air; therefore, long-term storage of the uranium chips presents a major fire hazard. The Oak Ridge Y-12 Plant Development Division was contacted to devise a disposal method that would eliminate chip burial and minimize storage space requirements. The proposed method of accomplishing this task was oxidizing the uranium chips to uranium oxide (U/sub 3/O/sub 8/) under controlled conditions. Pilot plant operation of the Uranium Chip Oxidation Facility (UCOF) was initiated on May 20, 1985, by the Y-12 Development Division. The purpose of this initial development testing was to evaluate the equipment, determine operating parameters, and provide on-the-job training for Waste Treatment Operations (WTO) personnel. Startup of the UCOF began with the check-out of the equipment using only the No. 1 oxidizer. Following the verification stage, the oxidizer was loaded with an initial charge of cold uranium oxide (U/sub 3/O/sub 8/) in preparation for test burning. Results of the test are given.

  19. Inter-plant coordination and its relationships with supply chain integration and operational performance

    DEFF Research Database (Denmark)

    Yang, Cheng; Chaudhuri, Atanu; Farooq, Sami

    2016-01-01

    Based on the data obtained from the sixth version of International Manufacturing Strategy Survey (IMSS VI), this paper explores the relationships at the level of plant between (1) inter-plant coordination and operational performance, and (2) between inter-plant coordination and internal/external ...... and customer integration; and (3) the relationships between inter-plant coordination and cost/flexibility are fully mediated by supplier integration.......Based on the data obtained from the sixth version of International Manufacturing Strategy Survey (IMSS VI), this paper explores the relationships at the level of plant between (1) inter-plant coordination and operational performance, and (2) between inter-plant coordination and internal...

  20. Ethnobotanical survey of toxic plants and plant parts in Ogun State, Nigeria

    Directory of Open Access Journals (Sweden)

    Adediwura A Fred-Jaiyesimi

    2012-01-01

    Full Text Available Background: Several plants considered toxic are sometimes identified in traditional medicinal recipes. This study identified and inventoried the plants and plant parts identified as toxic in targeted local government areas of Ogun State, Nigeria. Materials and Methods: By administering tested questionnaires, information on the poisonous or toxic plants, poisonous parts, poisonous effects, modes of poisoning, and antidotes was obtained. Results and Conclusion: Ninety-two species belonging to 43 families were identified as toxic plants and these were mainly members of the Euphorbiaceae and Fabaceae families. The botanical names, poisonous parts, common names, vernacular names, modes of poisoning, antidotes, and poisonous effects are presented in a table.

  1. Refining United States Policy on Offensive Cyber Operations

    Science.gov (United States)

    2014-11-01

    address state- sponsored cyber threats with a very different set of tools ranging from diplomacy to kinetic strikes. Categorizing attacks by actor will...AIR COMMAND AND STAFF COLLEGE AIR UNIVERSITY REFINING UNITED STATES POLICY ON OFFENSIVE CYBER OPERATIONS by Max...to offensive cyber warfare, specifically cyber exploitation and cyber attack. Current domestic and international policies lack mechanisms to

  2. Operation and Maintenance Manual for the Central Facilities Area Sewage Treatment Plant

    Energy Technology Data Exchange (ETDEWEB)

    Norm Stanley

    2011-02-01

    This Operation and Maintenance Manual lists operator and management responsibilities, permit standards, general operating procedures, maintenance requirements and monitoring methods for the Sewage Treatment Plant at the Central Facilities Area at the Idaho National Laboratory. The manual is required by the Municipal Wastewater Reuse Permit (LA-000141-03) the sewage treatment plant.

  3. Mathematics for Water and Wastewater Treatment Plant Operators. Water and Wastewater Training Program.

    Science.gov (United States)

    South Dakota Dept. of Environmental Protection, Pierre.

    This booklet is intended to aid the prospective waste treatment plant operator or drinking water plant operator in learning to solve mathematical problems, which is necessary for Class I certification. It deals with the basic mathematics which a Class I operator may require in accomplishing day-to-day tasks. The book also progresses into problems…

  4. 7 CFR 70.110 - Requirements for sanitation, facilities, and operating procedures in official plants.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Requirements for sanitation, facilities, and operating... Requirements for sanitation, facilities, and operating procedures in official plants. (a) The requirements for sanitation, facilities, and operating procedures in official plants shall be the applicable provisions...

  5. State regulation and power plant productivity: background and recommendations

    Energy Technology Data Exchange (ETDEWEB)

    1980-09-01

    This report was prepared by representatives of several state regulatory agencies. It is a guide to some of the activities currently under way in state agencies to promote increased availability of electrical generating power plants. Standard measures of plant performance are defined and the nature of data bases that report such measures is discussed. It includes reviews of current state, federal, and industry programs to enhance power plant productivity and provides detailed outlines of programs in effect in California, Illinois, Michigan, New York, North Carolina, Ohio, and Texas. A number of actions are presented that could be adopted by state regulatory agencies, depending on local conditions. They include: develop a commission position or policy statement to encourage productivity improvements by utilities; coordinate state efforts with ongoing industry and government programs to improve the acquisition of power plant performance data and the maintenance of quality information systems; acquire the capability to perform independent analyses of power plant productivity; direct the establishment of productivity improvement programs, including explicit performance objectives for both existing and planned power plants, and a performance program; establish a program of incentives to motivate productivity improvement activities; and participate in ongoing efforts at all levels and initiate new actions to promote productivity improvements.

  6. 76 FR 73720 - Knowledge and Abilities Catalog for Nuclear Power Plant Operators: Westinghouse AP1000...

    Science.gov (United States)

    2011-11-29

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Knowledge and Abilities Catalog for Nuclear Power Plant Operators: Westinghouse AP1000 Pressurized..., NUREG-2103, Revision 0, ``Knowledge and Abilities Catalog for Nuclear Power Plant...

  7. Full steady-state operation in Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Kazarian-Vibert, F.; Litaudon, X.; Moreau, D.; Arslanbekov, R.; Hoang, G.T.; Peysson, Y.

    1996-06-01

    In order to produce fully non-inductive, Lower Hybrid (LH) driven discharges in a systematic and reproducible manner, new operation modes have been studied on the superconducting TORE SUPRA tokamak. It is shown that this operation mode allows to reach full steady-state within a characteristic time of a few seconds. The underlying physics is described and a detailed analysis of the experiments is made. It is shown, in particular, that this operation scenario generates stable stationary plasmas with improved confinement, so that the so-called `LHEP` regime can be extrapolated to continuous operation. (K.A.). 19 refs.

  8. Optimization of operation for combined heat and power plants - CHP plants - with heat accumulators using a MILP formulation

    Energy Technology Data Exchange (ETDEWEB)

    Grue, Jeppe; Bach, Inger [Aalborg Univ. (Denmark). Inst. of Energy Technology]. E-mails: jeg@iet.auc.dk; ib@iet.auc.dk

    2000-07-01

    The power generation system in Denmark is extensively based on small combined heat and power plants (CHP plants), producing both electricity and district heating. This project deals with smaller plants spread throughout the country. Often a heat accumulator is used to enable electricity production, even when the heat demand is low. This system forms a very complex problem, both for sizing, designing and operation of CHP plants. The objective of the work is the development of a tool for optimisation of the operation of CHP plants, and to even considering the design of the plant. The problem is formulated as a MILP-problem. An actual case is being tested, involving CHP producing units to cover the demand. The results from this project show that it is of major importance to consider the operation of the plant in detail already in the design phase. It is of major importance to consider the optimisation of the plant operation, even at the design stage, as it may cause the contribution margin to rise significantly, if the plant is designed on the basis of a de-tailed knowledge of the expected operation. (author)

  9. Method and apparatus for optimizing operation of a power generating plant using artificial intelligence techniques

    Science.gov (United States)

    Wroblewski, David; Katrompas, Alexander M.; Parikh, Neel J.

    2009-09-01

    A method and apparatus for optimizing the operation of a power generating plant using artificial intelligence techniques. One or more decisions D are determined for at least one consecutive time increment, where at least one of the decisions D is associated with a discrete variable for the operation of a power plant device in the power generating plant. In an illustrated embodiment, the power plant device is a soot cleaning device associated with a boiler.

  10. Operating experience from Swedish nuclear power plants, 2000

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    From a safety point of view, 2000 was - as were previous years - satisfactory. Total electricity production from the Swedish nuclear power stations amounted to 54.2 TWh, which was over 20% less than the 70.2 TWh produced in 1999. The two main reasons for the reduction were the closure of Barsebaeck 1 on 1st December 1999, and the cutback in output from all reactors due to the particularly good availability of hydro power in 2000. Some reactors were even shut down completely as a result of the low power demand, which has not happened previously. The quantity of unutilised production capacity as a result of these reductions amounted to 11.6 TWh. Costdown operation prior to the annual overhaul shutdowns, which makes better use of the fuel, represented a further 2.1 TWh of unutilised capacity. The average energy availability of the three PWRs at Ringhals was 82.0%, while that of the eight BWRs was 84.2%. Forsmark 3, Ringhals 3 and Oskarshamn 3 all had average availabilities of over 90%. Of five events with safety implications that occurred in the plants during the year, three are described under Special Reporting. One of them relates to the crack indications in welds that were found in an American PWR in the autumn, and which were subsequently also found in Ringhals 4.

  11. Operating results 2015. Nuclear power plants. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2016-05-15

    A report is given on the opening results achieved in 2015, events important to plant safety, special and relevant repair, and retrofit measures from nuclear power plants in Germany. Reports about nuclear power plants in Belgium, Finland, the Netherlands, Switzerland, and Spain will be published in further issue.

  12. Estimation of pump operational state with model-based methods

    Energy Technology Data Exchange (ETDEWEB)

    Ahonen, Tero; Tamminen, Jussi; Ahola, Jero; Viholainen, Juha; Aranto, Niina [Institute of Energy Technology, Lappeenranta University of Technology, P.O. Box 20, FI-53851 Lappeenranta (Finland); Kestilae, Juha [ABB Drives, P.O. Box 184, FI-00381 Helsinki (Finland)

    2010-06-15

    Pumps are widely used in industry, and they account for 20% of the industrial electricity consumption. Since the speed variation is often the most energy-efficient method to control the head and flow rate of a centrifugal pump, frequency converters are used with induction motor-driven pumps. Although a frequency converter can estimate the operational state of an induction motor without external measurements, the state of a centrifugal pump or other load machine is not typically considered. The pump is, however, usually controlled on the basis of the required flow rate or output pressure. As the pump operational state can be estimated with a general model having adjustable parameters, external flow rate or pressure measurements are not necessary to determine the pump flow rate or output pressure. Hence, external measurements could be replaced with an adjustable model for the pump that uses estimates of the motor operational state. Besides control purposes, modelling the pump operation can provide useful information for energy auditing and optimization purposes. In this paper, two model-based methods for pump operation estimation are presented. Factors affecting the accuracy of the estimation methods are analyzed. The applicability of the methods is verified by laboratory measurements and tests in two pilot installations. Test results indicate that the estimation methods can be applied to the analysis and control of pump operation. The accuracy of the methods is sufficient for auditing purposes, and the methods can inform the user if the pump is driven inefficiently. (author)

  13. Procedure for estimating nonfuel operation and maintenance costs for large steam-electric power plants

    Energy Technology Data Exchange (ETDEWEB)

    Myers, M.L.; Fuller, L.C.

    1979-01-01

    Revised guidelines are presented for estimating annual nonfuel operation and maintenance costs for large steam-electric power plants, specifically light-water-reactor plants and coal-fired plants. Previous guidelines were published in October 1975 in ERDA 76-37, a Procedure for Estimating Nonfuel Operating and Maintenance Costs for Large Steam-Electric Power Plants. Estimates for coal-fired plants include the option of limestone slurry scrubbing for flue gas desulfurization. A computer program, OMCOST, is also presented which covers all plant options.

  14. State of the art review of radioactive waste volume reduction techniques for commercial nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    1980-04-01

    A review is made of the state of the art of volume reduction techniques for low level liquid and solid radioactive wastes produced as a result of: (1) operation of commercial nuclear power plants, (2) storage of spent fuel in away-from-reactor facilities, and (3) decontamination/decommissioning of commercial nuclear power plants. The types of wastes and their chemical, physical, and radiological characteristics are identified. Methods used by industry for processing radioactive wastes are reviewed and compared to the new techniques for processing and reducing the volume of radioactive wastes. A detailed system description and report on operating experiences follow for each of the new volume reduction techniques. In addition, descriptions of volume reduction methods presently under development are provided. The Appendix records data collected during site surveys of vendor facilities and operating power plants. A Bibliography is provided for each of the various volume reduction techniques discussed in the report.

  15. Research of Operation Modes of Heat Storage Tank in CHP Plant Using Numerical Simulation

    National Research Council Canada - National Science Library

    Streckiene, Giedre; Miseviciute, Violeta

    2011-01-01

    ... ________________ _________________________________________________________________________________ Volume 6 Re search of Operation Modes of Heat Storage Tank in CHP Plant Using Numerical Simulation Giedre Streckiene 1 , Violeta Miseviciute 2 , 1 - 2 Department...

  16. Synthane Pilot Plant, South Park Township, Pennsylvania. Run report No. 2-DB: operating period September 1977--September 1978

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-01

    This report covers the operation of the Synthane Coal Gasification Pilot Plant, South Park Township, Allegheny County, Pennsylvania from September 1977 through September 1978. The facility is owned by the United States Government and operated by C-E Lummus. Test Directive No. 2-DB directed the plant be operated with Illinois No. 6 coal from the River King Mine of the Peabody Coal Company at a pressure of 600 psig. Concurrent pretreater/gasifier operation was to take place at coal feed rates from 1.5 to 2.5 tons/hour. Gas was produced for 182 hours and 1,100 tons of coal were fed to the pretreater and gasifier. Continuous operation of up to 56 hours and carbon conversions based on char of up to 72% were achieved. This successful operation demonstrates that coal gasification via the Synthane Process is viable. Additional data are required for the design of a commercial facility; however, the data obtained to date are adequate to recommend improvements and modifications to the Synthane Process Pilot Plant to increase on stream time efficiency. The successful operation of the pilot plant with Illinois No. 6 coal demonstrates the feasibility of the Synthane Pilot Plant to process a caking type of coal. The ability to successfully pretreat a caking coal at high pressure in a plant of this size is a first and a direct result of the successful operation of the Synthane Process. Other similar type processes operated to date require pretreatment of a caking coal at atmospheric pressure with little or no recovery of the gases or heat produced during pretreatment.

  17. The Design and Research of the Operation Status Detector for Marine Engine Room Power Plant Based on Noise

    Directory of Open Access Journals (Sweden)

    Li Hang

    2016-01-01

    Full Text Available Designed in this paper, based on the noise of ship engine room power plant running status of detector, is mainly used in the operation of the power plant of acoustic shell size to determine when the machine running state, this device is composed of signal disposal and alarm display adjustment part of two parts. Detector that can show the size of the voice, if exceed the set limit alarm value, the detector can sound an alarm, to remind staff equipment fails, it shall timely inspection maintenance, improve the safety of the operation of the ship.

  18. Operational experience of the industrial plant for electron beam flue gas treatment

    Science.gov (United States)

    Chmielewski, Andrzej G.; Licki, Janusz; Pawelec, Andrzej; Tymiński, Bogdan; Zimek, Zbigniew

    2004-09-01

    Electron beam flue gas treatment technology is one of the most advanced technologies among new generation processes for air pollution control. The process, which has been developed in Japan, the United States, Germany and Poland allows simultaneous removal of SO 2 and NO x with high efficiency and by-product generated can be applied as fertilizer. Two industrial installations using this technology have been constructed in the world, one in China and the second in Poland. Other plants are constructed in Japan and China. Chinese installation is mostly SO 2 removal oriented (since the NO x emission limits in China are not imposed up to now), so Polish plant one is as a matter of fact the first installation for simultaneous desulfurization and denitrification of flue gases. The plant located in EPS Pomorzany in Szczecin treats the flue gases emitted from two Benson boilers of 65 MW e and 100 MW th each. The flue gases of maximum flow of 270 000 N m 3/h are irradiated by four accelerators of 700 keV electron energy and 260 kW beam power each. Description of the plant and the results obtained have been presented in this paper. The plant has been in operation for more than 2500 h (5500 h including one accelerator set operation). Removal efficiencies up to 95% for SO 2 and up to 70% for NO x were achieved. Several thousand tons of the by-product was sold in the form of NPK fertilizer. Economically, the technology is competitive with the conventional ones.

  19. Bell operator and Gaussian squeezed states in noncommutative quantum mechanics

    CERN Document Server

    Bastos, Catarina; Bertolami, Orfeu; Dias, Nuno Costa; Prata, João Nuno

    2015-01-01

    One examines putative corrections to the Bell operator due to the noncommutativity in the phase-space. Starting from a Gaussian squeezed envelop whose time evolution is driven by commutative (standard quantum mechanics) and noncommutative dynamics respectively, one concludes that, although the time evolving covariance matrix in the noncommutative case is different from the standard case, the squeezing parameter dominates and there are no noticeable noncommutative corrections to the Bell operator. This indicates that, at least for squeezed states, the privileged states to test Bell correlations, noncommutativity versions of quantum mechnics remains as non-local as quantum mechanics itself.

  20. Bell operator and Gaussian squeezed states in noncommutative quantum mechanics

    Science.gov (United States)

    Bastos, Catarina; Bernardini, Alex E.; Bertolami, Orfeu; Dias, Nuno Costa; Prata, João Nuno

    2016-05-01

    We examine putative corrections to the Bell operator due to the noncommutativity in the phase space. Starting from a Gaussian squeezed envelope whose time evolution is driven by commutative (standard quantum mechanics) and noncommutative dynamics, respectively, we conclude that although the time-evolving covariance matrix in the noncommutative case is different from the standard case, the squeezing parameter dominates and there are no noticeable noncommutative corrections to the Bell operator. This indicates that, at least for squeezed states, the privileged states to test Bell correlations, noncommutativity versions of quantum mechanics remain as nonlocal as quantum mechanics itself.

  1. Operation reliability analysis of independent power plants of gas-transmission system distant production facilities

    Directory of Open Access Journals (Sweden)

    Piskunov Maksim V.

    2015-01-01

    Full Text Available The new approach was developed to analyze the failure causes in operation of linear facilities independent power supply sources (mini-CHP-plants of gas-transmission system in Eastern part of Russia. Triggering conditions of ceiling operation substance temperature at condenser output were determined with mathematical simulation use of unsteady heat and mass transfer processes in condenser of mini-CHP-plants. Under these conditions the failure probability in operation of independent power supply sources is increased. Influence of environmental factors (in particular, ambient temperature as well as output electric capability values of power plant on mini-CHP-plant operation reliability was analyzed. Values of mean time to failure and power plant failure density during operation in different regions of Eastern Siberia and Far East of Russia were received with use of numerical simulation results of heat and mass transfer processes at operation substance condensation.

  2. Solid Waste from the Operation and Decommissioning of Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Marilyn Ann [Georgia Inst. of Technology, Atlanta, GA (United States); D' Arcy, Daniel [Georgia Inst. of Technology, Atlanta, GA (United States); Lapsa, Melissa Voss [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sharma, Isha [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Li, Yufei [Georgia Inst. of Technology, Atlanta, GA (United States)

    2017-01-05

    This baseline report examines the solid waste generated by the U.S. electric power industry, including both waste streams resulting from electricity generation and wastes resulting from the decommissioning of power plants. Coal and nuclear plants produce large volumes of waste during electricity generation, and this report describes the policies and procedures for handling these materials. Natural gas and oil-fired power plants face similar waste challenges. Renewables considered in this baseline report include hydropower, wind and solar.

  3. Small-State Special Operations in a Comprehensive Stabilisation Context

    DEFF Research Database (Denmark)

    Johnsen, Anton Asklund

    the most important arguments, reflections and conclusion made at the conference. The conference was initiated in order to establish an academic forum, wherein relevant questions could be posed which would allow to pinpoint and guide future research on the utility of small state operations. The key...... takeaways were: Special operations as a force multiplier: Can special operations enable other stabilisation agents, locals as well as internationals, to accomplish their missions more effectively? This includes NGOs, diplomats or other officials, other military units, etc. How can the mindset required...

  4. State Machine Framework And Its Use For Driving LHC Operational states

    CERN Document Server

    Misiowiec, M; Solfaroli Camilloci, M

    2011-01-01

    The LHC follows a complex operational cycle with 12 major phases that include equipment tests, preparation, beam injection, ramping and squeezing, finally followed by the physics phase. This cycle is modelled and enforced with a state machine, whereby each operational phase is represented by a state. On each transition, before entering the next state, a series of conditions is verified to make sure the LHC is ready to move on. The State Machine framework was developed to cater for building independent or embedded state machines. They safely drive between the states executing tasks bound to transitions and broadcast related information to interested parties. The framework encourages users to program their own actions. Simple configuration management allows the operators to define and maintain complex models themselves. An emphasis was also put on easy interaction with the remote state machine instances through standard communication protocols. On top of its core functionality, the framework offers a transparen...

  5. Guangxi Shanglin Aluminum Plant cross-regional technical upgrade project(phase 1)put into operation

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    <正>The project(Phase 1)of cross-regional techni- cal upgrade of the aluminum plant of Guangxi Shanglin Nannan Industrial Co.was completed and put into operation on June 8,2007.The plant is a cross-regional technical upgrade pro- ject of Nanning Aluminum Plant,featuring the integration of coal,electricity and aluminum.

  6. 78 FR 46255 - Revisions to Environmental Review for Renewal of Nuclear Power Plant Operating Licenses; Correction

    Science.gov (United States)

    2013-07-31

    ... COMMISSION 10 CFR Part 51 RIN 3150-AI42 Revisions to Environmental Review for Renewal of Nuclear Power Plant... environmental effect of renewing the operating license of a nuclear power plant. Compliance with the provisions... nuclear power plant. This document is necessary to clarify and correct the revisions made to the......

  7. 78 FR 50458 - Entergy Nuclear Operations, Inc., James A. Fitzpatrick Nuclear Power Plant, Vermont Yankee...

    Science.gov (United States)

    2013-08-19

    ... COMMISSION Entergy Nuclear Operations, Inc., James A. Fitzpatrick Nuclear Power Plant, Vermont Yankee Nuclear... petitioners'') has requested that the NRC take action with regard to James A. Fitzpatrick Nuclear Power Plant... with regard to James A. Fitzpatrick Nuclear Power Plant (Fitzpatrick), Vermont Yankee Nuclear...

  8. Telebroadcasting of a Cat-like State via Local Operations

    Institute of Scientific and Technical Information of China (English)

    文海丹; 李传锋; 郭光灿

    2001-01-01

    The quantum telebroadcasting of a cat-like state in combination with the quantum teleportation and the local copying of entanglement is presented. This gives a general way of distributing entanglement among distant parties. All of the operations of our scenario are local and within the reach of current technology.

  9. Mean values of local operators in highly excited Bethe states

    NARCIS (Netherlands)

    Pozsgay, B.

    2011-01-01

    We consider expectation values of local operators in (continuum) integrable models in a situation when the mean value is calculated in a single Bethe state with a large number of particles. We develop a form factor expansion for the thermodynamic limit of the mean value, which applies whenever the d

  10. Distributed Low-Complexity Controller for Wind Power Plant in Derated Operation

    DEFF Research Database (Denmark)

    Biegel, Benjamin; Madjidian, Daria; Spudic, Vedrana;

    2013-01-01

    We consider a wind power plant of megawatt wind turbines operating in derated mode. When operating in this mode, the wind power plant controller is free to distribute power set-points to the individual turbines, as long as the total power demand is met. In this work, we design a controller...

  11. Operation of Wastewater Treatment Plants: A Field Study Training Program. Volume I. Second Edition.

    Science.gov (United States)

    California State Univ., Sacramento. Dept. of Civil Engineering.

    This manual was prepared by experienced wastewater collection system workers to provide a home study course to develop new qualified workers and expand the abilities of existing workers. This volume is directed primarily towards entry-level operators and the operators of ponds, package plants, or small treatment plants. Ten chapters examine the…

  12. 78 FR 16302 - Crystal River Unit 3 Nuclear Generating Plant, Application for Amendment to Facility Operating...

    Science.gov (United States)

    2013-03-14

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Crystal River Unit 3 Nuclear Generating Plant, Application for Amendment to Facility Operating... Operating License No. DPR-72 for the Crystal River Unit 3 Nuclear Generating Plant (CR-3), located in...

  13. 9 CFR 354.210 - Minimum standards for sanitation, facilities, and operating procedures in official plants.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Minimum standards for sanitation, facilities, and operating procedures in official plants. 354.210 Section 354.210 Animals and Animal Products... sanitation, facilities, and operating procedures in official plants. The provisions of §§ 354.210 to...

  14. 78 FR 66779 - United States Enrichment Corporation, Paducah Gaseous Diffusion Plant, Including On-Site Leased...

    Science.gov (United States)

    2013-11-06

    ... Employment and Training Administration United States Enrichment Corporation, Paducah Gaseous Diffusion Plant... Corporation, Paducah Gaseous Diffusion Plant, including on-site leased workers from Diversified Management...: All workers of United States Enrichment Corporation, Paducah Gaseous Diffusion Plant,......

  15. Multidimensional solid-state NMR spectroscopy of plant cell walls.

    Science.gov (United States)

    Wang, Tuo; Phyo, Pyae; Hong, Mei

    2016-09-01

    Plant biomass has become an important source of bio-renewable energy in modern society. The molecular structure of plant cell walls is difficult to characterize by most atomic-resolution techniques due to the insoluble and disordered nature of the cell wall. Solid-state NMR (SSNMR) spectroscopy is uniquely suited for studying native hydrated plant cell walls at the molecular level with chemical resolution. Significant progress has been made in the last five years to elucidate the molecular structures and interactions of cellulose and matrix polysaccharides in plant cell walls. These studies have focused on primary cell walls of growing plants in both the dicotyledonous and grass families, as represented by the model plants Arabidopsis thaliana, Brachypodium distachyon, and Zea mays. To date, these SSNMR results have shown that 1) cellulose, hemicellulose, and pectins form a single network in the primary cell wall; 2) in dicot cell walls, the protein expansin targets the hemicellulose-enriched region of the cellulose microfibril for its wall-loosening function; and 3) primary wall cellulose has polymorphic structures that are distinct from the microbial cellulose structures. This article summarizes these key findings, and points out future directions of investigation to advance our fundamental understanding of plant cell wall structure and function.

  16. Controversy over Biomass Plant at Florida State Heats up

    Science.gov (United States)

    Mangan, Katherine

    2009-01-01

    This article reports that Florida State University officials are gearing up for what could be another bruising battle this month over a proposed biomass plant that could bring the campus cleaner, cheaper energy and monetary support for alternative-energy research. Or, it could bring noise and pollution to a nearby neighborhood, according to…

  17. Hydraulic modelling of drinking water treatment plant operations

    OpenAIRE

    L. C. Rietveld; Borger, K.J.; Van Schagen, K.M.; Mesman, G.A.M.; G. I. M. Worm

    2008-01-01

    For a drinking water treatment plant simulation, water quality models, a hydraulic model, a process-control model, an object model, data management, training and decision-support features and a graphic user interface have been integrated. The integration of a hydraulic model in the simulator is necessary to correctly determine the division of flows over the plant's lanes and, thus, the flow through the individual treatment units, based on valve positions and pump speeds. The flow through a un...

  18. Operation of Finnish nuclear power plants. Quarterly report 3rd quarter, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Tossavainen, K. [ed.

    1995-03-01

    Quarterly Reports on the operation of Finnish nuclear power plants describe nuclear and radiation safety related events and observations which the Finnish Centre for Radiation and Nuclear Safety (STUK) considers safety significant. Safety improvements at the plants and general matters relating to the use of nuclear energy are also reported. A summary of the radiation safety of plant personnel and of the environment, and tabulated data on the plants` production and load factors are also given. (4 figs., 4 tabs.).

  19. Operating costs and plant options analysis for the Shamokin fluidized bed boiler

    Energy Technology Data Exchange (ETDEWEB)

    Klett, M.G.; Dowdy, T.E.; Litman, R.

    1984-03-01

    This report presents the results of a study that examined the operating costs and options to improve the Shamokin Atmospheric Fluidized Bed Combustion Demonstration Plant located near Shamokin, Pennsylvania. The purpose of this study was to perform an operating cost analysis and compare the results with projected operating costs. An analysis was also made to identify possible cost savings options. Two base case scenarios were developed for this study: the first scenario assumed that the plant operated in a manner similar to operations during the extended test program; and the second scenario was concerned with two options. One option assumed upgrading the plant to achieve continuous full load operation, restarting, and used revised costs and revenues. The second assumed reconfiguring the plant for cogeneration.

  20. Single qubit operations with base squeezed coherent states

    Science.gov (United States)

    Podoshvedov, Sergey A.

    2013-03-01

    In quantum computing with base either coherent or squeezed coherent states, information is encoded into coherent states with opposite amplitudes. To exploit the base states in quantum computation, we need arbitrary qubit rotations plus a two-qubit gate such as controlled-Z gate to simulate any multiqubit unitary transformations. We develop an approach to realize single qubit operations with the base squeezed coherent states. The optical setup requires a resource of the base squeezed coherent states, unbalanced beam splitter whose transmittance tends to unity and photon counters in auxiliary modes. A successful two-photon subtraction from transmitted beam is heralded by two-photon click in auxiliary modes where tiny part of the initial beam is detected. The thrust of the method is that it achieves a high fidelity without photodetectors with a high efficiency or a single-photon resolution. We observe that there is wide diapason of values of the parameters that provide performance of single qubit operations with the base states. The problem is resolved in Wigner representation to take into account imperfections of the optical devices.

  1. Value as a parameter to consider in operational strategies for CSP plants

    Science.gov (United States)

    de Meyer, Oelof; Dinter, Frank; Govender, Saneshan

    2017-06-01

    This paper introduced a value parameter to consider when analyzing operational strategies for CSP plants. The electric system in South Africa, used as case study, is severely constrained with an influx of renewables in the early phase of deployment. The energy demand curve for the system is analyzed showing the total wind and solar photovoltaic contributions for winter and summer. Due to the intermittent nature and meteorological operating conditions of wind and solar photovoltaic plants, the value of CSP plants within the electric system is introduced. Analyzing CSP plants based on the value parameter alone will remain only a philosophical view. Currently there is no quantifiable measure to translate the philosophical view or subjective value and it solely remains the position of the stakeholder. By introducing three other parameters, Cost, Plant and System to a holistic representation of the Operating Strategies of generation plants, the Value parameter can be translated into a quantifiable measure. Utilizing the country's current procurement program as case study, CSP operating under the various PPA within the Bid Windows are analyzed. The Value Cost Plant System diagram developed is used to quantify the value parameter. This paper concluded that no value is obtained from CSP plants operating under the Bid Window 1 & 2 Power Purchase Agreement. However, by recognizing the dispatchability potential of CSP plants in Bid Window 3 & 3.5, the value of CSP in the electric system can be quantified utilizing Value Added Relationship VCPS-diagram. Similarly ancillary services to the system were analyzed. One of the relationships that have not yet been explored within the industry is an interdependent relationship. It was emphasized that the cost and value structure is shared between the plant and system. Although this relationship is functional when the plant and system belongs to the same entity, additional value is achieved by marginalizing the cost structure. A

  2. Development of a Nuclear Plant Analyzer for Education and Operation Guide of the CANDU Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Suk, Su Dong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Oh, S. K.; Kim, H. D.; Cho, U. Y.; Lim, J. C.; Kim, S. B.; Kim, H. J.; Park, J. W.; Yeom, C. S.; Suh, J. S.; Park, K. S.; Jung, J. B.; Lee, K. M.; Ahn, H. J.; Lee, I. K. [Institute for Advanced Engineering, Yongin (Korea, Republic of)

    1997-09-01

    Operator training through the utilization of the NPA can improve efficiently the operator`s capability to cope with plant abnormal behaviors and enhance the safety and operability of nuclear power plants (NPP). Recent trend toward the computing automation and integrated design approach in NPP design analysis recognizes importance of the utilization of NPA technology. Major efforts are made into the expansion of functional capability of the CANDU plant simulation/analysis program obtained through the previous CANDU engineering R and D activities at IAE and into the development of configuration design technology for visualization through graphic display network. Through the simulation tests on the predictive capability of the plant simulation/analysis program and the examination of behavior of the plant operation parameters in typical operational and upset transients, the validation and improvement of the models for the major plant systems have been made. The reactor kinetics model has been improved for 3-D neutronic transient problems. Reactor burnup calculation and on-power fuelling capability have been modelled for the CANDU in-core fuel management practice. Furthermore, the graphic display of simulation results and control panels is user-interactively visualized, and the establishment of basic distributed computing network system through server/client concept with multimedia technique are tried for real time simulation and computational efficiency. The present simulation program has a limitation on the analysis for fast transient problems because of the lack of the explicit two-phase flow model, however, a CANDU NPA which has been developed as the mid-term part of our long term goal constructing `Simulation Based CANDU Design and Analysis System` is anticipated to be used as an assistant tool for nuclear system engineers and plant operators, and as a basic tool for the development of an advanced integrated engineering analyzer. 29 refs., 9 tabs., 110 figs

  3. Simulation platform of economical operation and dispatch for power plant based on float-coded genetic algorithm

    Institute of Scientific and Technical Information of China (English)

    朱奕; 伞冶; 马克茂

    2004-01-01

    This paper discusses a float-coded genetic algorithm and its application to the optimization of the power plant operation concerning the simulation problem of economical operation for power plant systems. The method proposed realizes the load optimization between generating units of power plants and their loads, solves the problem of influence of a unit plant pause spoilage and load variance on the optimal plant combination and load, and finally establishes a simulation platform for the power plant economical operation.

  4. An integrated framework for gas turbine based power plant operational modeling and optimization

    Science.gov (United States)

    Zhao, Yongjun

    The deregulation of the electric power market introduced a strong element of competition. Power plant operators strive to develop advanced operational strategies to maximize the profitability in the dynamic electric power market. New methodologies for gas turbine power plant operational modeling and optimization are needed for power plant operation to enhance operational decision making, and therefore to maximize power plant profitability by reducing operations and maintenance cost and increasing revenue. In this study, a profit based, lifecycle oriented, and unit specific methodology for gas turbine based power plant operational modeling was developed, with the power plant performance, reliability, maintenance, and market dynamics considered simultaneously. The generic methodology is applicable for a variety of optimization problems, and several applications were implemented using this method. A multiple time-scale method was developed for gas turbine power plants long term generation scheduling. This multiple time-scale approach allows combining the detailed granularity of the day-to-day operations with global (seasonal) trends, while keeping the resulting optimization model relatively compact. Using the multiple time-scale optimization method, a profit based outage planning method was developed, and the key factors for this profit based approach include power plant aging, performance degradation, reliability degradation, and, importantly, the energy market dynamics. Also a novel approach for gas turbine based power plant sequential preventive maintenance scheduling was introduced, and a profit based sequential preventive maintenance scheduling was developed for more effective maintenance scheduling. Methods to evaluate the impact of upgrade packages on gas turbine power plant performance, reliability, and economics were developed, and TIES methodology was applied for effective evaluation and selection of gas turbine power plant upgrade packages.

  5. Optimization of wastewater treatment plant operation for greenhouse gas mitigation.

    Science.gov (United States)

    Kim, Dongwook; Bowen, James D; Ozelkan, Ertunga C

    2015-11-01

    This study deals with the determination of optimal operation of a wastewater treatment system for minimizing greenhouse gas emissions, operating costs, and pollution loads in the effluent. To do this, an integrated performance index that includes three objectives was established to assess system performance. The ASMN_G model was used to perform system optimization aimed at determining a set of operational parameters that can satisfy three different objectives. The complex nonlinear optimization problem was simulated using the Nelder-Mead Simplex optimization algorithm. A sensitivity analysis was performed to identify influential operational parameters on system performance. The results obtained from the optimization simulations for six scenarios demonstrated that there are apparent trade-offs among the three conflicting objectives. The best optimized system simultaneously reduced greenhouse gas emissions by 31%, reduced operating cost by 11%, and improved effluent quality by 2% compared to the base case operation.

  6. Two years of operational experiences with Vattenfall's oxyfuel pilot plant

    Energy Technology Data Exchange (ETDEWEB)

    Altmann, Hubertus [Vattenfall Europe Mining and Generation, Cottbus (Germany); Porsche, Thomas [Vattenfall Europe Generation AG, Cottbus (Germany)

    2010-07-01

    Directly linked to Vattenfall's ambition to be one of the leading European energy companies the strategic target is set, to reduce the specific CO{sub 2} emission caused by the production of electricity and heat by 50 per cent until 2030 and to produce heat and electricity climate neutral by 2050. These reduction targets stand in line with the plans of the European Union and the German government and go even beyond them. First results from the operation of the Oxyfuel pilot plant are available now. These real and comprehensible results are now the foundation for further planning and building activities and they guarantee a successful future development of CCS power plant technology. From today's point of view, technical obstacles which are still in the way of CCS can be overcome. It can be stated by now that Oxyfuel works in pilot scale, all emission limits are kept and necessary CO{sub 2} purities are achieved. The integration of plant parts from chemical engineering (ASU, CO{sub 2}-plant) were done successfully. The transfer of knowledge from pilot to demonstration plant is organised. There is a need of research and development to further increase efficiency and availability. Financial funding is necessary for the demo project and acceptance for CCS und CO{sub 2}-storage needs to be improved in public and politics. Nevertheless, the question whether CCS technology will be successful or not does not only depend on its profitability but is also a question of acceptance. We do not only have to illustrate the importance of coal and lignite for a reliable and affordable power supply to the people in our country and in entire Europe. We also have to provide answers to their simple questions regarding the safety of transport systems and the leak-proof of CO{sub 2} storage areas. These are the aspects we have to focus on and where we have to supply the right arguments. (orig.)

  7. Indicator methods to evaluate the hygienic performance of industrial scale operating Biowaste Composting Plants.

    Science.gov (United States)

    Martens, Jürgen

    2005-01-01

    The hygienic performance of biowaste composting plants to ensure the quality of compost is of high importance. Existing compost quality assurance systems reflect this importance through intensive testing of hygienic parameters. In many countries, compost quality assurance systems are under construction and it is necessary to check and to optimize the methods to state the hygienic performance of composting plants. A set of indicator methods to evaluate the hygienic performance of normal operating biowaste composting plants was developed. The indicator methods were developed by investigating temperature measurements from indirect process tests from 23 composting plants belonging to 11 design types of the Hygiene Design Type Testing System of the German Compost Quality Association (BGK e.V.). The presented indicator methods are the grade of hygienization, the basic curve shape, and the hygienic risk area. The temperature courses of single plants are not distributed normally, but they were grouped by cluster analysis in normal distributed subgroups. That was a precondition to develop the mentioned indicator methods. For each plant the grade of hygienization was calculated through transformation into the standard normal distribution. It shows the part in percent of the entire data set which meet the legal temperature requirements. The hygienization grade differs widely within the design types and falls below 50% for about one fourth of the plants. The subgroups are divided visually into basic curve shapes which stand for different process courses. For each plant the composition of the entire data set out of the various basic curve shapes can be used as an indicator for the basic process conditions. Some basic curve shapes indicate abnormal process courses which can be emended through process optimization. A hygienic risk area concept using the 90% range of variation of the normal temperature courses was introduced. Comparing the design type range of variation with the

  8. Remote state preparation using positive operator-valued measures

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Siendong, E-mail: sdhuang@mail.ndhu.edu.tw [Department of Applied Mathematics, National Dong Hwa University, Hualien 974, Taiwan (China)

    2013-02-04

    We consider the process of remote state preparation using a pure state |ψ〉 with the maximal Schmidt number n. For any given state σ, pure or mixed, a construction of a positive operator-valued measure {M_j}{sub j=0}{sup n} is provided. The classical outcome j=0 indicates the failure of a remote preparation of σ. All other classical outcomes j>0 correspond to unitary transformations of the receiver system such that σ can be prepared. The total probability of successful remote preparation depends on the state σ. Our protocol is a variation of conclusive teleportation and the classical bits required for this protocol are given by log{sub 2}(n+1), which is nearly half that of conclusive teleportation.

  9. Exergy Analysis of Operating Lignite Fired Thermal Power Plant

    Directory of Open Access Journals (Sweden)

    K. Murugesan

    2009-01-01

    Full Text Available The energy assessment must be made through the energy quantity as well as the quality. But the usual energy analysisevaluates the energy generally on its quantity only. However, the exergy analysis assesses the energy on quantity as well asthe quality. The aim of the exergy analysis is to identify the magnitudes and the locations of real energy losses, in order toimprove the existing systems, processes or components. The present paper deals with an exergy analysis performed on anoperating 50MWe unit of lignite fired steam power plant at Thermal Power Station-I, Neyveli Lignite Corporation Limited,Neyveli, Tamil Nadu, India. The exergy losses occurred in the various subsystems of the plant and their components havebeen calculated using the mass, energy and exergy balance equations. The distribution of the exergy losses in several plantcomponents during the real time plant running conditions has been assessed to locate the process irreversibility. The Firstlaw efficiency (energy efficiency and the Second law efficiency (exergy efficiency of the plant have also been calculated.The comparison between the energy losses and the exergy losses of the individual components of the plant shows that themaximum energy losses of 39% occur in the condenser, whereas the maximum exergy losses of 42.73% occur in the combustor.The real losses of energy which has a scope for the improvement are given as maximum exergy losses that occurredin the combustor.

  10. Operations GUNNERSIDE and GROUSE - Special Operations During World War II Against the German Controlled Heavy Water Plant in Norway

    Science.gov (United States)

    2010-04-07

    Vemork be attacked with sufficient force to destroy all accumulated stocks of heavy water , the major pieces of machinery in the electrolysis plant...chain reaction within the nuclear reactor . Jens-Anton Poulsson, The Heavy Water Raid: The Race for the Atom Bomb 1942-1944 (Orion Forlag AS, 2009...Special Operations during N/A World War ll against the German Controlled Heavy Water Plant in NoiWay. 5b. GRANT NUMBER N/A 5c. PROGRAM ELEMENT NUMBER

  11. Analysis of Pending Problems for a Technology Demand of Domestic Operational Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Dae Seo; Park, Won Seok; Wi, Myung Hwan; Ha, Jae Joo

    2008-01-15

    Eleven technology fields were chosen, which have a relation with the solution of the pending problems of domestic operational nuclear power plants to manage an efficient operation and safe regulation for domestic nuclear power plants. The progressive background, requirements, and performance on the pending problems, 34, of an operation and regulation for domestic nuclear power plants were analyzed with regard to a risk information application, severe accident, PSR of structural materials, underwater monitoring, operation inspection and a fire protection, an instrument aging, metal integrity and steam generator, human technology and a digital I and C, quality assurance, secondary system and a user reliance and mass communications. KAERI's role is to provide a solution to these pending problems of domestic nuclear power plants. KAERI's technology is to be applicable to the pending problems for domestic nuclear power plants to raise an operational efficiency and an application frequency of nuclear power plants. In the future, a technology treaty between KAERI and KHNP is to be established to solve the pending problems for domestic nuclear power plants. Operation rate of nuclear power plants will also be raised and contribute to the supply of national energy due to this technology treaty.

  12. Hydraulic modelling of drinking water treatment plant operations

    Directory of Open Access Journals (Sweden)

    K. J. Borger

    2008-10-01

    Full Text Available For a drinking water treatment plant simulation, water quality models, a hydraulic model, a process-control model, an object model, data management, training and decision-support features and a graphic user interface have been integrated. The integration of a hydraulic model in the simulator is necessary to correctly determine the division of flows over the plant's lanes and, thus, the flow through the individual treatment units, based on valve positions and pump speeds. The flow through a unit is one of the most important parameters in terms of a unit's effectiveness. In the present paper, a new EPAnet library is presented with the typical hydraulic elements for drinking water treatment processes. Using this library, a hydraulic model was set up and validated for the drinking water treatment plant Harderbroek.

  13. Operation of Finnish nuclear power plants. Quarterly report, 2nd quarter 1997

    Energy Technology Data Exchange (ETDEWEB)

    Tossavainen, K. [ed.

    1997-12-01

    Quarterly Reports on the operation of Finnish nuclear power plants describe events and observations relating to nuclear and radiation safety which STUK - Radiation and Nuclear Safety Authority considers safety significant. Safety improvements at the plants are also described. The Report also includes a summary of the radiation safety of plant personnel and of the environment and tabulated data on the plants` production and load factors. The Finnish nuclear power plant units were in power operation in the second quarter of 1997, except for the annual maintenance outages of Olkiluoto plant units and the Midsummer outage at Olkiluoto 2 due to reduced demand for electricity. There were also brief interruptions in power operation at the Olkiluoto plant units due to three reactor scrams. All plant units are undergoing long-term test operation at upgraded reactor power level which has been approved by STUK The load factor average of all plant units was 88.7 %. One event in the second quarter of 1997 was classified level 1 on the INES. The event in question was a scram at Olkiluoto 1 which was caused by erroneous opening of switches. Other events in this quarter were level 0. Occupational doses and radioactive releases off-site were below authorized limits. Radioactive substances were measurable in samples collected around the plants in such quantities only as have no bearing on the radiation exposure of the population. (orig.).

  14. Wind Power Plants Fundamentals, Design, Construction and Operation

    CERN Document Server

    Twele, Jochen

    2012-01-01

    Wind power plants teaches the physical foundations of usage of Wind Power. It includes the areas like Construction of Wind Power Plants, Design, Development of Production Series, Control, and discusses the dynamic forces acting on the systems as well as the power conversion and its connection to the distribution system. The book is written for graduate students, practitioners and inquisitive readers of any kind. It is based on lectures held at several universities. Its German version it already is the standard text book for courses on Wind Energy Engineering but serves also as reference for practising engineers.

  15. Steady State Dynamic Operating Behavior of Universal Motor

    Directory of Open Access Journals (Sweden)

    Muhammad Khan Burdi

    2015-01-01

    Full Text Available A detailed investigation of the universal motor is developed and used for various dynamic steady state and transient operating conditions of loads. In the investigation, output torque, motor speed, input current, input/output power and efficiency are computed, compared and analyzed for different loads. While this paper discusses the steady-state behavior of the universal motor, another companion paper, ?Transient dynamic behavior of universal motor?, will discuss its transient behavior in detail. A non-linear generalized electric machine model of the motor is considered for the analysis. This study was essential to investigate effect of output load on input current, power, speed and efficiency of the motor during operations. Previously such investigation is not known

  16. Optimal operation of Petlyuk distillation: Steady-state behavior

    OpenAIRE

    Ivar J. Halvorsen; Sigurd Skogestad

    2001-01-01

    The "Petlyuk" or "dividing-wall" or "fully thermally coupled" distillation column is an interesting alternative to the conventional cascaded binary columns for separation of multi-component mixtures. However, the industrial use has been limited, and difficulties in operation have been reported as one reason. With three product compositions controlled, the system has two degrees of freedom left for on-line optimization. We show that the steady-state optimal solution surface is quite narrow, an...

  17. Skinner boxes for psychotics: Operant conditioning at Metropolitan state hospital

    OpenAIRE

    Rutherford, Alexandra

    2003-01-01

    Between 1953 and 1965, Ogden Lindsley and his associates conducted free-operant research with psychiatric inpatients and normal volunteers at Metropolitan State Hospital in Waltham, Massachusetts. Their project, originally named “Studies in Behavior Therapy,” was renamed “Harvard Medical School Behavior Research Laboratory” in 1955. This name change and its implications were significant. The role of the laboratory in the history of the relationship between the experimental analysis of behavio...

  18. Co-operativity in a nanocrystalline solid-state transition

    Science.gov (United States)

    White, Sarah L.; Smith, Jeremy G.; Behl, Mayank; Jain, Prashant K.

    2013-12-01

    Co-operativity is a remarkable phenomenon mostly seen in biology, where initial reaction events significantly alter the propensity of subsequent reaction events, giving rise to a nonlinear tightly regulated synergistic response. Here we have found unique evidence of atomic level co-operativity in an inorganic material. A thousand-atom nanocrystal (NC) of the inorganic solid cadmium selenide exhibits strong positive co-operativity in its reaction with copper ions. A NC doped with a few copper impurities becomes highly prone to be doped even further, driving an abrupt transition of the entire NC to the copper selenide phase, as manifested by a strongly sigmoidal response in optical spectroscopy and electron diffraction measurements. The examples presented here suggest that cooperative phenomena may have an important role in the solid state, especially in the nucleation of new chemical phases, crystal growth, and other materials’ transformations.

  19. Co-operativity in a nanocrystalline solid-state transition.

    Science.gov (United States)

    White, Sarah L; Smith, Jeremy G; Behl, Mayank; Jain, Prashant K

    2013-01-01

    Co-operativity is a remarkable phenomenon mostly seen in biology, where initial reaction events significantly alter the propensity of subsequent reaction events, giving rise to a nonlinear tightly regulated synergistic response. Here we have found unique evidence of atomic level co-operativity in an inorganic material. A thousand-atom nanocrystal (NC) of the inorganic solid cadmium selenide exhibits strong positive co-operativity in its reaction with copper ions. A NC doped with a few copper impurities becomes highly prone to be doped even further, driving an abrupt transition of the entire NC to the copper selenide phase, as manifested by a strongly sigmoidal response in optical spectroscopy and electron diffraction measurements. The examples presented here suggest that cooperative phenomena may have an important role in the solid state, especially in the nucleation of new chemical phases, crystal growth, and other materials' transformations.

  20. On Volterra quadratic stochastic operators with continual state space

    Energy Technology Data Exchange (ETDEWEB)

    Ganikhodjaev, Nasir; Hamzah, Nur Zatul Akmar [Department of Computational and Theoretical Sciences, Faculty of Science, International Islamic University, Jalan Sultan Ahmad Shah, Bandar Indera Mahkota, 25200 Kuantan, Pahang (Malaysia)

    2015-05-15

    Let (X,F) be a measurable space, and S(X,F) be the set of all probability measures on (X,F) where X is a state space and F is σ - algebraon X. We consider a nonlinear transformation (quadratic stochastic operator) defined by (Vλ)(A) = ∫{sub X}∫{sub X}P(x,y,A)dλ(x)dλ(y), where P(x, y, A) is regarded as a function of two variables x and y with fixed A ∈ F . A quadratic stochastic operator V is called a regular, if for any initial measure the strong limit lim{sub n→∞} V{sup n }(λ) is exists. In this paper, we construct a family of quadratic stochastic operators defined on the segment X = [0,1] with Borel σ - algebra F on X , prove their regularity and show that the limit measure is a Dirac measure.

  1. Water Treatment Plant Operation. Volume I. A Field Study Training Program.

    Science.gov (United States)

    California State Univ., Sacramento. School of Engineering.

    The purpose of this water treatment field study training program is to: (1) develop new qualified water treatment plant operators; (2) expand the abilities of existing operators, permitting better service both to employers and public; and (3) prepare operators for civil service and certification examinations (examinations administered by…

  2. Water Treatment Plant Operation. Volume II. A Field Study Training Program.

    Science.gov (United States)

    California State Univ., Sacramento. School of Engineering.

    The purpose of this water treatment field study training program is to: (1) develop new qualified water treatment plant operators; (2) expand the abilities of existing operators, permitting better service both to employers and public; and (3) prepare operators for civil service and certification examinations (examinations administered by…

  3. Water Treatment Plant Operation Volume 2. A Field Study Training Program. Revised.

    Science.gov (United States)

    California State Univ., Sacramento. School of Engineering.

    The purpose of this water treatment field study training program is to: (1) develop new qualified water treatment plant operators; (2) expand the abilities of existing operators, permitting better service both to employers and public; and (3) prepare operators for civil service and certification examinations (examinations administered by…

  4. Operation of Wastewater Treatment Plants. Volume 1. A Field Study Training Program. Third Edition. Revised.

    Science.gov (United States)

    California State Univ., Sacramento. Dept. of Civil Engineering.

    The purpose of this wastewater treatment field study training program is to: (1) develop new qualified wastewater treatment plant operators; (2) expand the abilities of existing operators, permitting better service both to employers and public; and (3) prepare operators for civil service and certification examinations (examinations administered by…

  5. Full steady-state operation in Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Kazarian-Vibert, F.; Litaudon, X.; Moreau, D.; Arslanbekov, R.; Hoang, G.T.; Peysson, Y. [Association Euratom-CEA, Centre d`Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee

    1996-12-01

    In order to produce fully non-inductive, lower hybrid (LH) driven discharges in a systematic and reproducible manner, new operation modes have been studied on the superconducting Tore Supra tokamak. To cope with some uncertainties in the LH current drive efficiency (e.g. profile dependences), the plasma current is not imposed a priori, but evolves freely until the equilibrium (which depends on the LH power level) is reached. The voltage applied on the primary circuit no longer controls the plasma current. In an `open loop` scenario in which this voltage is present and constant, the timescale required to attain the equilibrium is the longest characteristic time of the coupled plasma-poloidal field coils system ({approx} 60 s). In order to obtain a stationary state faster, a new feedback scheme has been implemented in which the primary circuit voltage is controlled in such a way that the flux consumption vanishes. It is shown that this operation mode allows full steady-state to be reached within a characteristic time of a few seconds. The underlying physics is described and a detailed analysis of the experiments is made. It is shown, in particular, that this operation scenario generates stable stationary plasmas with improved confinement, so that the so-called `LHEP` regime can be extrapolated to continuous operation. (Author).

  6. Laguna Verde BWRs operational experience: steady-state fuel performance

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas V, G. F.; Bravo S, J. M. [Global Nuclear Fuel - Americas, 3901 Castle Hayne Road, Wilmington, 28401 North Carolina (United States); Casillas, J. L., E-mail: gabriel.cuevas-vivas@gnf.co [General Electric Hitachi Nuclear Energy, 1989 Little Orchard St. Romm 239, San Jose, 95125 California (United States)

    2010-10-15

    The two BWR at Laguna Verde nuclear power station are finishing 21 and 15 years of continuous successful operation as of 2010. During Unit 1 and 2 commercial operations only Ge/GNF fuel designs have been employed; fuel lattice designs 8 x 8 and 10 x 10 were used at the reactor, with an original licensed thermal power (OLTP: 1931 MWt) and the reactor's first power up-rates of 5%. GNF fuel will be also used for the second EPU to reach 120% of OLTP in the near future. Thermal and gamma traversing in-core probes (Tip) are used for power monitoring purposes along with the Ge (now GNF-A) core monitoring system, 3-dimensional Monicore{sup TM}. GNF-A has also participated by preparing the core management plan that is regularly fine-tuned in collaboration with Comision Federal de Electricidad (CFE owner of the Laguna Verde reactors). For determination of thermal margins and eigenvalue prediction, GNF-A employs the NRC-licensed steady-state core simulator PANAC11. Tip comparisons are routinely used to adapt power distributions for a better thermal margin calculation. Over the years, several challenges have appeared in the near and long term fuel management planning such as increasing cycle length, optimization of the thermal margins, rated power increase, etc. Each challenge has been successfully overcome via operational strategy, code improvements and better fuel designs. This paper summarizes Laguna Verde Unit 1 and 2 steady-state performance from initial commercial operation, with a discussion of the nuclear and thermal-hydraulic design features, as well as of the operational strategies that set and interesting benchmark for future fuel applications, code development and operation of the BWRs. (Author)

  7. Energy prices and substitution in United States manufacturing plants

    Science.gov (United States)

    Grim, Cheryl

    Persistent regional disparities in electricity prices, growth in wholesale power markets, and recent deregulation attempts have intensified interest in the performance of the U.S. electric power industry, while skyrocketing fuel prices have brought renewed interest in the effect of changes in prices of all energy types on the U.S. economy. This dissertation examines energy prices and substitution between energy types in U.S. manufacturing. I use a newly constructed database that includes information on purchased electricity and electricity expenditures for more than 48,000 plants per year and additional data on the utilities that supply electricity to study the distribution of electricity prices paid by U.S. manufacturing plants from 1963 to 2000. I find a large compression in the dispersion of electricity prices from 1963 to 1978 due primarily to a decrease in quantity discounts for large electricity purchasers. I also find that spatial dispersion in retail electricity prices among states, counties and utility service territories is large, rises over time for smaller purchasers, and does not diminish as wholesale power markets expand in the 1990s. In addition, I examine energy type consumption patterns, prices, and substitution in U.S. manufacturing plants. I develop a plant-level dataset for 1998 with data on consumption and expenditures on energy and non-energy production inputs, output, and other plant characteristics. I find energy type consumption patterns vary widely across manufacturing plants. Further, I find a large amount of dispersion across plants in the prices paid for electricity, oil, natural gas, and coal. These high levels of dispersion are accounted for by the plant's location, industry, and purchase quantity. Finally, I present estimates of own- and cross-price elasticities of demand for both the energy and non-energy production inputs.

  8. Hydraulic modelling of drinking water treatment plant operations

    NARCIS (Netherlands)

    Worm, G.I.M.; Mesman, G.A.M.; Van Schagen, K.M.; Borger, K.J.; Rietveld, L.C.

    2009-01-01

    The flow through a unit of a drinking water treatment plant is one of the most important parameters in terms of a unit's effectiveness. In the present paper, a new EPAnet library is presented with the typical hydraulic elements for drinking water treatment processes well abstraction, rapid sand filt

  9. Operational Optimization of Large-Scale Parallel-Unit SWRO Desalination Plant Using Differential Evolution Algorithm

    Directory of Open Access Journals (Sweden)

    Jian Wang

    2014-01-01

    Full Text Available A large-scale parallel-unit seawater reverse osmosis desalination plant contains many reverse osmosis (RO units. If the operating conditions change, these RO units will not work at the optimal design points which are computed before the plant is built. The operational optimization problem (OOP of the plant is to find out a scheduling of operation to minimize the total running cost when the change happens. In this paper, the OOP is modelled as a mixed-integer nonlinear programming problem. A two-stage differential evolution algorithm is proposed to solve this OOP. Experimental results show that the proposed method is satisfactory in solution quality.

  10. Effect of operating conditions and reactor configuration on efficiency of full-scale biogas plants

    DEFF Research Database (Denmark)

    Angelidaki, Irini; Boe, Kanokwan; Ellegaard, L.

    2005-01-01

    A study on 18 full-scale centralized biogas plants was carried out in order to find significant operational factors influencing productivity and stability of the plants. It was found that the most plants were operating relatively stable with volatile fatty acids (VFA) concentration below 1.5 g....../l. VFA concentration increase was observed in occasions with dramatic overloading or other disturbances such as operational temperature changes. Ammonia was found to be a significant factor for stability. A correlation between increased residual biogas production and high ammonia was found. When ammonia...

  11. Standard Operating Procedures, MCSP Monarch and Plant Monitoring, 2016

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This record contains the six Standard Operating Procedure (SOP) of the initial survey instructions (ISI) developed and followed for surveys conducted as part of the...

  12. Hydraulic modelling of drinking water treatment plant operations

    Directory of Open Access Journals (Sweden)

    L. C. Rietveld

    2009-06-01

    Full Text Available The flow through a unit of a drinking water treatment plant is one of the most important parameters in terms of a unit's effectiveness. In the present paper, a new EPAnet library is presented with the typical hydraulic elements for drinking water treatment processes well abstraction, rapid sand filtration and cascade and tower aeration. Using this treatment step library, a hydraulic model was set up, calibrated and validated for the drinking water treatment plant Harderbroek. With the actual valve position and pump speeds, the flows were calculated through the several treatment steps. A case shows the use of the model to calculate the new setpoints for the current frequency converters of the effluent pumps during a filter backwash.

  13. Operator training for the Yacyreta binational hydroelectric power plant; Formacion de operadores para la Central Hidroelectrica de Yacireta

    Energy Technology Data Exchange (ETDEWEB)

    Dure, Francisco; Tachella, Heriberto [Entidad Binacional Yacyreta, Isla Yacireta (Paraguay). Central Hidroelectrica Yacyreta]. E-mail: yacyreta@internet.siscotel.com

    1998-07-01

    This work is oriented to the power plant operators, by exposing the criteria and methods adopted for operators selection, training and incorporation to the Yacyreta Hydroelectric Power Plant. The used criteria considered some aspects, as follows: the operation staff should be consisted of equal numbers of Argentine and Paraguayan nationalities, viewing the both systems operation; experience of the shift supervisors in operating a plant for a minimum of 10 years; the supervisors should participate training the auxiliary operators.

  14. Operating boundaries of full-scale advanced water reuse treatment plants: many lessons learned from pilot plant experience.

    Science.gov (United States)

    Bele, C; Kumar, Y; Walker, T; Poussade, Y; Zavlanos, V

    2010-01-01

    Three Advanced Water Treatment Plants (AWTP) have recently been built in South East Queensland as part of the Western Corridor Recycled Water Project (WCRWP) producing Purified Recycled Water from secondary treated waste water for the purpose of indirect potable reuse. At Luggage Point, a demonstration plant was primarily operated by the design team for design verification. The investigation program was then extended so that the operating team could investigate possible process optimisation, and operation flexibility. Extending the demonstration plant investigation program enabled monitoring of the long term performance of the microfiltration and reverse osmosis membranes, which did not appear to foul even after more than a year of operation. The investigation primarily identified several ways to optimise the process. It highlighted areas of risk for treated water quality, such as total nitrogen. Ample and rapid swings of salinity from 850 to 3,000 mg/l-TDS were predicted to affect the RO process day-to-day operation and monitoring. Most of the setpoints used for monitoring under HACCP were determined during the pilot plant trials.

  15. The United States national volcanic ash operations plan for aviation

    Science.gov (United States)

    Albersheim, Steven; Guffanti, Marianne

    2009-01-01

    Volcanic-ash clouds are a known hazard to aviation, requiring that aircraft be warned away from ash-contaminated airspace. The exposure of aviation to potential hazards from volcanoes in the United States is significant. In support of existing interagency operations to detect and track volcanic-ash clouds, the United States has prepared a National Volcanic Ash Operations Plan for Aviation to strengthen the warning process in its airspace. The US National Plan documents the responsibilities, communication protocols, and prescribed hazard messages of the Federal Aviation Administration, National Oceanic and Atmospheric Administration, US Geological Survey, and Air Force Weather Agency. The plan introduces a new message format, a Volcano Observatory Notice for Aviation, to provide clear, concise information about volcanic activity, including precursory unrest, to air-traffic controllers (for use in Notices to Airmen) and other aviation users. The plan is online at http://www.ofcm.gov/p35-nvaopa/pdf/FCM-P35-2007-NVAOPA.pdf. While the plan provides general operational practices, it remains the responsibility of the federal agencies involved to implement the described procedures through orders, directives, etc. Since the plan mirrors global guidelines of the International Civil Aviation Organization, it also provides an example that could be adapted by other countries.

  16. Reactor operating procedures for startup of continuously-operated chemical plants

    NARCIS (Netherlands)

    Verwijs, J.W.; Kösters, P.H.; Berg, van den H.; Westerterp, K.R.

    1995-01-01

    Rules are presented for the startup of an adiabatic tubular reactor, based on a qualitative analysis of the dynamic behavior of continuously-operated vapor- and liquid-phase processes. The relationships between the process dynamics, operating criteria, and operating constraints are investigated, sin

  17. Guide to the selection, training, and licensing or certification of reprocessing plant operators. Volume I

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-06-01

    The Code of Federal Regulations, Title 10, Part 55, establishes procedures and criteria for the licensing of operators, including senior operators, in ''Production and Utilization Facilities'', which includes plants for reprocessing irradiated fuel. A training guide is presented which will facilitate the licensing of operators for nuclear reprocessing plants by offering generalized descriptions of the basic principles (theory) and the unit operations (mechanics) employed in reprocessing spent fuels. In the present volume, details about the portions of a training program that are of major interest to management are presented. (JSR)

  18. Integration of chemical product development, process design and operation based on a kilo-plant

    Institute of Scientific and Technical Information of China (English)

    QIAN Yu; WU Zhihui; JIANG Yanbin

    2006-01-01

    Presented in this paper is an integrated approach of computer-aided product development, process design and operation analysis based on a kilo-plant. The implemented kilo-plant, as a research platform to manufacture product in kilogram-scale, was designed especially for fine and specialty chemicals. The characteristics of product synthesis, process operation and product quality control are investigated coupled with computer-aided monitoring, online modeling, simulation and operation process optimization. In this way, chemical product discovery, process design and operation are integrated in a systematic approach, in the aim to respond to rapid changing marketplace demands to new products.

  19. Knowledge and abilities catalog for nuclear power plant operators: Pressurized water reactors. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This document provides the basis for the development of content-valid licensing examinations for reactor operators and senior reactor operators. The examinations developed using the PWR catalog will cover those topics listed under Title 10, (ode of Federal Regulations Part 55. The PWR catalog contains approximately 5100 knowledge and ability (K/A) statements for reactor operators and senior reactor operators. The catalog is organized into six major sections: Catalog Organization; Generic Knowledge and Abilities; Plant Systems; Emergency and Abnormal Plant Evolutions; Components and Theory.

  20. Scenarios for low carbon and low water electric power plant operations: implications for upstream water use

    Data.gov (United States)

    U.S. Environmental Protection Agency — The dataset includes all data used in the creation of figures and graphs in the paper: "Scenarios for low carbon and low water electric power plant operations:...

  1. Automatic Facial Expression Recognition and Operator Functional State

    Science.gov (United States)

    Blanson, Nina

    2012-01-01

    The prevalence of human error in safety-critical occupations remains a major challenge to mission success despite increasing automation in control processes. Although various methods have been proposed to prevent incidences of human error, none of these have been developed to employ the detection and regulation of Operator Functional State (OFS), or the optimal condition of the operator while performing a task, in work environments due to drawbacks such as obtrusiveness and impracticality. A video-based system with the ability to infer an individual's emotional state from facial feature patterning mitigates some of the problems associated with other methods of detecting OFS, like obtrusiveness and impracticality in integration with the mission environment. This paper explores the utility of facial expression recognition as a technology for inferring OFS by first expounding on the intricacies of OFS and the scientific background behind emotion and its relationship with an individual's state. Then, descriptions of the feedback loop and the emotion protocols proposed for the facial recognition program are explained. A basic version of the facial expression recognition program uses Haar classifiers and OpenCV libraries to automatically locate key facial landmarks during a live video stream. Various methods of creating facial expression recognition software are reviewed to guide future extensions of the program. The paper concludes with an examination of the steps necessary in the research of emotion and recommendations for the creation of an automatic facial expression recognition program for use in real-time, safety-critical missions

  2. Assessment of LWR piping design loading based on plant operating experience

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, P. O.

    1980-08-01

    The objective of this study has been to: (1) identify current Light Water Reactor (LWR) piping design load parameters, (2) identify significant actual LWR piping loads from plant operating experience, (3) perform a comparison of these two sets of data and determine the significance of any differences, and (4) make an evaluation of the load representation in current LWR piping design practice, in view of plant operating experience with respect to piping behavior and response to loading.

  3. Reducing water freshwater consumption at coal-fired power plants : approaches used outside the United States.

    Energy Technology Data Exchange (ETDEWEB)

    Elcock, D. (Environmental Science Division)

    2011-05-09

    Coal-fired power plants consume huge quantities of water, and in some water-stressed areas, power plants compete with other users for limited supplies. Extensive use of coal to generate electricity is projected to continue for many years. Faced with increasing power demands and questionable future supplies, industries and governments are seeking ways to reduce freshwater consumption at coal-fired power plants. As the United States investigates various freshwater savings approaches (e.g., the use of alternative water sources), other countries are also researching and implementing approaches to address similar - and in many cases, more challenging - water supply and demand issues. Information about these non-U.S. approaches can be used to help direct near- and mid-term water-consumption research and development (R&D) activities in the United States. This report summarizes the research, development, and deployment (RD&D) status of several approaches used for reducing freshwater consumption by coal-fired power plants in other countries, many of which could be applied, or applied more aggressively, at coal-fired power plants in the United States. Information contained in this report is derived from literature and Internet searches, in some cases supplemented by communication with the researchers, authors, or equipment providers. Because there are few technical, peer-reviewed articles on this topic, much of the information in this report comes from the trade press and other non-peer-reviewed references. Reducing freshwater consumption at coal-fired power plants can occur directly or indirectly. Direct approaches are aimed specifically at reducing water consumption, and they include dry cooling, dry bottom ash handling, low-water-consuming emissions-control technologies, water metering and monitoring, reclaiming water from in-plant operations (e.g., recovery of cooling tower water for boiler makeup water, reclaiming water from flue gas desulfurization [FGD] systems), and

  4. A Post Licensing Study of Community Effects at Two Operating Nuclear Power Plants. Final Report.

    Science.gov (United States)

    Purdy, Bruce J.; And Others

    In an effort to identify and assess the social, economic, and political effects of nuclear power plant construction and operation upon two host communities (Plymouth, Massachusetts and Waterford, Connecticut), a post-licensing review revealed that the primary impact of the nuclear power plants in both communities was an increase in the property…

  5. Edge states for the Dirac operator on manifolds with boundary

    CERN Document Server

    Govindarajan, T R

    2015-01-01

    We investigate the properties of the Dirac operator on manifolds with boundaries in presence of the Atiyah-Patodi-Singer boundary condition. An exact counting of the number of edge states for boundaries with isometry of a sphere is given. We show that the problem with the above boundary condition can be mapped to one where the manifold is extended beyond the boundary and the boundary condition is replaced by a delta function potential of suitable strength. We also briefly highlight how the problem of the self-adjointness of the operators in the presence of moving boundaries can be simplified by suitable transformations which render the boundary fixed and modify the Hamiltonian and the boundary condition to reflect the effect of moving boundary.

  6. Optimal operation of Petlyuk distillation: Steady-state behavior

    Directory of Open Access Journals (Sweden)

    Ivar J. Halvorsen

    2001-07-01

    Full Text Available The "Petlyuk" or "dividing-wall" or "fully thermally coupled" distillation column is an interesting alternative to the conventional cascaded binary columns for separation of multi-component mixtures. However, the industrial use has been limited, and difficulties in operation have been reported as one reason. With three product compositions controlled, the system has two degrees of freedom left for on-line optimization. We show that the steady-state optimal solution surface is quite narrow, and depends strongly on disturbances and design parameters. Thus it seems difficult to achieve the potential energy savings compared to conventional approaches without a good control strategy. We discuss candidate variables which may be used as feedback variables in order to keep the column operation close to optimal in a "self-optimizing" control scheme.

  7. Archimede solar energy molten salt parabolic trough demo plant: Improvements and second year of operation

    Science.gov (United States)

    Maccari, Augusto; Donnola, Sandro; Matino, Francesca; Tamano, Shiro

    2016-05-01

    Since July 2013, the first stand-alone Molten Salt Parabolic Trough (MSPT) demo plant, which was built in collaboration with Archimede Solar Energy and Chiyoda Corporation, is in operation, located adjacent to the Archimede Solar Energy (ASE) manufacturing plant in Massa Martana (Italy). During the two year's operating time frame, the management of the demo plant has shown that MSPT technology is a suitable and reliable option. Several O&M procedures and tests have been performed, as Heat Loss and Minimum Flow Test, with remarkable results confirming that this technology is ready to be extended to standard size CSP plant, if the plant design takes into account molten salt peculiarities. Additionally, the plant has been equipped on fall 2014 with a Steam Generator system by Chiyoda Corporation, in order to test even this important MSPT plant subsystem and to extend the solar field active time, overcoming the previous lack of an adequate thermal load. Here, a description of the plant improvements and the overall plant operation figures will be presented.

  8. Toxicity Tests for Ensuring Succesful Industrial Wastewater Treatment Plant Operation

    Science.gov (United States)

    Cěbere, B.; Faltiņa, E.; Zelčāns, N.; Kalniņa, D.

    2009-01-01

    Industrial wastewaters are complex and can be polluted by non-biodegradable end toxic organic compounds and are a serious threat to the environment. Chemical procedure alone cannot provide sufficient information. A complete evaluation of wastewaters should include ecotoxicological tests too, especially concerning the complex wastewaters. In the literature review the authors attempted to establish which is the more promising and suitable aquatic toxicology test for sewage treatment plant influent toxicity monitoring. A variety of types of organisms representing different trophic levels and many different species are used for aquatic toxicity testing. Toxicity characterization would be needed both for influents and effluents of wastewater treatment plant. For the purpose of screening biological wastewater treatment influent, toxicity to activated sludge microorganisms is important and toxicology tests here used are respirometry and bioluminescence toxicology tests. Respirometry toxicity tests are easy, fast and inexpensive compared to other approaches. Bioluminescence has been widely used, the most thoroughly investigated test system is the Microtox. The toxicity tests have also been compared by different authors. International, national and regional authorities use these tools to meet various regulatory and legislative requirements. Importance of biotesting has been emphasized also in EU legislation.

  9. 77 FR 29701 - Impact of Construction (Under a Combined License) of New Nuclear Power Plant Units on Operating...

    Science.gov (United States)

    2012-05-18

    ... a Combined License) of New Nuclear Power Plant Units on Operating Units at Multi-Unit Sites AGENCY... a COL intending to construct and operate new nuclear power plants (NPPs) on multi-unit sites to... Impacts of Construction (under a Combined License) of New Nuclear Power Plants on Operating Units at...

  10. CTS (Hermes): United States experiments and operations summary

    Science.gov (United States)

    Donoughe, P. L.; Hunczak, H. R.

    1977-01-01

    The Communications Technology Satellite, launched in January 1976 and embodying the highest power transmitter in a communications satellite, was considered. As a joint program between the U.S. and Canada, close coordination of the two countries was necessitated since the management and control of experiments were done in real time. Criteria used by NASA for acceptance of the United States experiments are noted and acceptance procedures are discussed. The category for each accepted experiment is given. The modus operandi employed for the U.S. experiments in the areas of management, coordination, liaison, and real time operation are described. Some of the highlights associated with satellite utilization are given.

  11. Simulating Entangling Unitary Operator Using Non-maximally Entangled States

    Institute of Scientific and Technical Information of China (English)

    LI Chun-Xian; WANG Cheng-Zhi; NIE Liu-Ying; LI Jiang-Fan

    2009-01-01

    We use non-maximally entangled states (NMESs) to simulate an entangling unitary operator (EUO) w/th a certain probability. Given entanglement resources, the probability of the success we achieve is a decreasing function of the parameters of the EUO. Given an EUO, for certain entanglement resources the result is optimal, i.e., the probability obtains a maximal value, and for optimal result higher parameters of the EUO match more amount of entanglement resources. The probability of the success we achieve is higher than the known results under some condition.

  12. Cluster state preparation using gates operating at arbitrary success probabilities

    Science.gov (United States)

    Kieling, K.; Gross, D.; Eisert, J.

    2007-06-01

    Several physical architectures allow for measurement-based quantum computing using sequential preparation of cluster states by means of probabilistic quantum gates. In such an approach, the order in which partial resources are combined to form the final cluster state turns out to be crucially important. We determine the influence of this classical decision process on the expected size of the final cluster. Extending earlier work, we consider different quantum gates operating at various probabilites of success. For finite resources, we employ a computer algebra system to obtain the provably optimal classical control strategy and derive symbolic results for the expected final size of the cluster. We identify two regimes: when the success probability of the elementary gates is high, the influence of the classical control strategy is found to be negligible. In that case, other figures of merit become more relevant. In contrast, for small probabilities of success, the choice of an appropriate strategy is crucial.

  13. Robust Solid State Quantum System Operating at 800 K

    CERN Document Server

    Kianinia, Mehran; Regan, Blake; Tran, Toan Trong; Ford, Michael J; Aharonovich, Igor; Toth, Milos

    2016-01-01

    Realization of Quantum information and communications technologies requires robust, stable solid state single photon sources. However, most existing sources cease to function above cryogenic or room temperature due to thermal ionization or strong phonon coupling which impede their emissive and quantum properties. Here we present an efficient single photon source based on a defect in a van der Waals crystal that is optically stable and operates at elevated temperatures of up to 800 K. The quantum nature of the source and the photon purity are maintained upon heating to 800 K and cooling back to room temperature. Our report of a robust high temperature solid state single photon source constitutes a significant step to-wards practical, integrated quantum technologies for real-world environments.

  14. Geothermal power plants of the United States: a technical survey of existing and planned installations

    Energy Technology Data Exchange (ETDEWEB)

    DiPippo, R.

    1978-04-01

    The development of geothermal energy as a source of electric power in the United States is reviewed. A thorough description is given of The Geysers geothermal power project in northern California. The recent efforts to exploit the hot-water resources of the Mexicali-Imperial Rift Valley are described. Details are given concerning the geology of the several sites now being used and for those at which power plants will soon be built. Attention is paid to the technical particulars of all existing plants, including wells, gathering systems, energy conversion devices, materials, environmental impacts, economics and operating characteristics. Specifically, plants which either exist or are planned for the following locations are covered: The Geysers, CA; East Mesa, CA; Heber, CA; Roosevelt Hot Springs, UT; Valles Caldera, NM; Salton Sea, CA; Westmorland, CA; Brawley, CA; Desert Peak, NV; and Raft River, ID. The growth of installed geothermal electric generating capacity is traced from the beginning in 1960 and is projected to 1984.

  15. IMPACT OF THE COLD END OPERATING CONDITIONS ON ENERGY EFFICIENCY OF THE STEAM POWER PLANTS

    Directory of Open Access Journals (Sweden)

    Slobodan Laković

    2010-01-01

    Full Text Available The conventional steam power plant working under the Rankine Cycle and the steam condenser as a heat sink and the steam boiler as a heat source have the same importance for the power plant operating process. Energy efficiency of the coal fired power plant strongly depends on its turbine-condenser system operation mode. For the given thermal power plant configuration, cooling water temperature or/and flow rate change generate alterations in the condenser pressure. Those changes have great influence on the energy efficiency of the plant. This paper focuses on the influence of the cooling water temperature and flow rate on the condenser performance, and thus on the specific heat rate of the coal fired plant and its energy efficiency. Reference plant is working under turbine-follow mode with an open cycle cooling system. Analysis is done using thermodynamic theory, in order to define heat load dependence on the cooling water temperature and flow rate. Having these correlations, for given cooling water temperature it is possible to determine optimal flow rate of the cooling water in order to achieve an optimal condensing pressure, and thus, optimal energy efficiency of the plant. Obtained results could be used as useful guidelines in improving existing power plants performances and also in design of the new power plants.

  16. Reduction of operations and maintenance costs at geothermal power plants

    Energy Technology Data Exchange (ETDEWEB)

    Bruton, C.J.; Stevens, C.G.; Rard, J.A.; Kasameyer, P.W. [Lawrence Livermore National Lab., CA (United States)

    1997-12-31

    To reduce chemical costs at geothermal power plants, we are investigating: (a) improved chemical processes associated with H{sub 2}S abatement techniques, and (b) the use of cross dispersive infrared spectrometry to monitor accurately, reliably, and continuously H{sub 2}S emissions from cooling towers. The latter is a new type of infrared optical technology developed by LLNL for non-proliferation verification. Initial work is focused at The Geysers in cooperation with Pacific Gas and Electric. Methods for deploying the spectrometer on-site at The Geysers are being developed. Chemical analysis of solutions involved in H{sub 2}S abatement technologies is continuing to isolate the chemical forms of sulfur produced.

  17. Safety requirements to the operation of hydropower plants; Sicherheit beim Betrieb von Wasserkraftwerken

    Energy Technology Data Exchange (ETDEWEB)

    Lux, Reinhard [Berufsgenossenschaft Energie Textil Elektro Medienerzeugnisse (BG ETEM), Koeln (Germany)

    2011-07-01

    Employers have to take into account various safety and health requirements relating to the design, construction, operation and maintenance of hydropower plants. Especially the diversity of the hydropower plant components requires the consideration of different safety and health aspects. In 2011 the ''Fachausschuss Elektrotechnik'' (expert committee electro-technics) of the institution for statutory accident insurance and prevention presented a new ''BG-Information'' dealing with ''Safe methods operating hydropower plants''. The following article gives an introduction into the conception and the essential requirements of this new BG-Information. (orig.)

  18. Ergonomic study of an operator's work of a molybdenum plant.

    Science.gov (United States)

    Oñate, Esteban; Meyer, Felipe

    2012-01-01

    This study was part of an ergonomic program which is being carried out through an agreement between the University of Concepción and a Chilean private mining company. The purpose of this case study was to identify working conditions in which the physical and mental workload could be over the capabilities of the operator. He was responsible for loading trucks with sacks of molybdenum and for downloading reagents and handles them. The methods employed in this study included electronic records, interviews, surveys, review of the company standards, a time study and physical and mental workload analysis. Results showed that 84% of the time the operator was carrying out principal and secondary activities and no break periods were detected. It was found that the pace of work and the shift system generated unfavorable conditions by imbalance in the workload on the different days of the week. In the light of the results recommendations were made for a number of ergonomic changes. Most of them were accepted by the company. The most important achievement was a change in the shift system. The overload of the operator was due to the fact that he was in a shift working 5 days and resting on weekends. The imbalance was mainly because the work of the week end was accumulated for Monday. As a result of the study, the company contracted a second worker for this job and adopted a 7x7 shift system, meaning that they work seven days and rest seven days. An evaluation carried out two month after adopting the new shift revealed that changes were well accepted by the worker.

  19. Solar steam supply: Initial operation of a plant

    OpenAIRE

    Krüger, Dirk; Lichtenthäler, Niels; Dersch, Jürgen; Schenk, Heiko; Hennecke, Klaus; Anthrakidis, Anette; Rusack, Markus; Lokurlu, Ahmet; Saidi, Karim; Walder, Marcus; Fischer, Stephan; Wirth, Hans Peter

    2011-01-01

    This paper describes experiences in operating a parabolic trough collector field for process heat supply by direct steam generation. The solar steam generator has been running automatically since its start in 2010 except for a winter pause up to now, August 2011, without any malfunction. It has supplied steam at 4 bar absolute and 143°C to the main production steam line on sunny days. Direct steam generation has proven to be a viable technology to supply saturated steam to an industrial st...

  20. Knowledge and abilities catalog for nuclear power plant operators: Boiling water reactors, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    The Knowledge and Abilities Catalog for Nuclear Power Plant Operators: Boiling-Water Reactors (BWRs) (NUREG-1123, Revision 1) provides the basis for the development of content-valid licensing examinations for reactor operators (ROs) and senior reactor operators (SROs). The examinations developed using the BWR Catalog along with the Operator Licensing Examiner Standards (NUREG-1021) and the Examiner`s Handbook for Developing Operator Licensing Written Examinations (NUREG/BR-0122), will cover the topics listed under Title 10, Code of Federal Regulations, Part 55 (10 CFR 55). The BWR Catalog contains approximately 7,000 knowledge and ability (K/A) statements for ROs and SROs at BWRs. The catalog is organized into six major sections: Organization of the Catalog, Generic Knowledge and Ability Statements, Plant Systems grouped by Safety Functions, Emergency and Abnormal Plant Evolutions, Components, and Theory. Revision 1 to the BWR Catalog represents a modification in form and content of the original catalog. The K/As were linked to their applicable 10 CFR 55 item numbers. SRO level K/As were identified by 10 CFR 55.43 item numbers. The plant-wide generic and system generic K/As were combined in one section with approximately one hundred new K/As. Component Cooling Water and Instrument Air Systems were added to the Systems Section. Finally, High Containment Hydrogen Concentration and Plant Fire On Site evolutions added to the Emergency and Abnormal Plant Evolutions section.

  1. Operation of Wastewater Treatment Plants: A Field Study Training Program. Volume II. Second Edition.

    Science.gov (United States)

    California State Univ., Sacramento. Dept. of Civil Engineering.

    This manual was prepared by experienced wastewater collection system workers to provide a home study course to develop new qualified workers and expand the abilities of existing workers. This volume emphasizes material needed by intermediate-level operators and stresses the operation and maintenance of conventional treatment plants. This volume…

  2. Introduction to Chemistry for Water and Wastewater Treatment Plant Operators. Water and Wastewater Training Program.

    Science.gov (United States)

    South Dakota Dept. of Environmental Protection, Pierre.

    Presented are basic concepts of chemistry necessary for operators who manage drinking water treatment plants and wastewater facilities. It includes discussions of chemical terms and concepts, laboratory procedures for basic analyses of interest to operators, and discussions of appropriate chemical calculations. Exercises are included and answer…

  3. 7 CFR 56.18 - Schedule of operation of official plants.

    Science.gov (United States)

    2010-01-01

    ... (CONTINUED) VOLUNTARY GRADING OF SHELL EGGS Grading of Shell Eggs Licensed and Authorized Graders § 56.18 Schedule of operation of official plants. Grading operating schedules for services performed pursuant to §§ 56.52 and 56.54 shall be requested in writing and be approved by the Administrator. Normal...

  4. 7 CFR 70.18 - Schedule of operation of official plants.

    Science.gov (United States)

    2010-01-01

    ... (CONTINUED) VOLUNTARY GRADING OF POULTRY PRODUCTS AND RABBIT PRODUCTS Grading of Poultry Products and Rabbit Products General § 70.18 Schedule of operation of official plants. Grading operation schedules for services performed pursuant to §§ 70.76 and 70.77 shall be requested in writing and be approved by the...

  5. Total simulation of operator team behavior in emergencies at nuclear power plants.

    Science.gov (United States)

    Takano, K; Sunaoshi, W; Suzuki, K

    2000-09-01

    In a large and complex system (i.e., a space aeronautics and nuclear power plant) it would be valuable to conduct operator training and support to demonstrate standard operators' behavior in coping with an anomaly caused by multiple malfunctions in which procedures would not have been stipulated previously. A system simulating operator team behavior including individual operator's cognitive behavior, his operations and physical behavior, and even verbal communication among team members, has been developed for a typical commercial nuclear power plant. This simulation model is not a scenario-based system but a complete knowledge-based system, based on the mental model that was envisaged by detailed analyses of experimental results obtained in the full-scope plant simulator. This mental model is composed of a set of knowledge bases and rules able to generate both diagnosis and prognosis depending on the observed situation even for multiple malfunctions. Simulation results of operator team behavior and plant dynamics were compared with corresponding experiments in several anomalies of multiple malfunctions. The comparison showed a reasonable agreement, so the simulation conditions were varied on cognitive task processing speed of individual operators, on team role sharing scheme, and on human machine interface (1st generation to 2nd generation control panel) to assess the sensitivity of this simulation model. Finally, it was shown that this simulation model has applications for the use of training standards and computer aided operator support systems.

  6. Thermal-Hydraulic Analysis Tasks for ANAV NPPs in Support of Plant Operation and Control

    OpenAIRE

    2007-01-01

    Thermal-hydraulic analysis tasks aimed at supporting plant operation and control of nuclear power plants are an important issue for the Asociación Nuclear Ascó-Vandellòs (ANAV). ANAV is the consortium that runs the Ascó power plants (2 units) and the Vandellòs-II power plant. The reactors are Westinghouse-design, 3-loop PWRs with an approximate electrical power of 1000 MW. The Technical University of Catalonia (UPC) thermal-hydraulic analysis team has jointly worked togeth...

  7. Simulation and comparison of different operational strategies for storage utilization in concentrated solar power plants

    Science.gov (United States)

    García-Barberena, Javier; Erdocia, Ioseba

    2016-05-01

    The increase of electric power demand and the wish to protect the environment are leading to a change in the energy sources. Conventional energy plants are losing strength against the renewable energy plants and, in particular, solar energy plants have a huge potential to provide clean energy supply for the increasing world's energy demand. Among the existing solar technologies, Concentrating Solar Power (CSP) is one of the most promising technologies. One of the major advantages of CSP plants is the technically feasible and cost-effective integration of Thermal Energy Storage (TES) systems. To increase the plant dispatchability, it is possible to create different operational strategies defining how such TES system is used. In this work, different strategies with different overall goals have been simulated over a complete year and the results are presented and compared here to demonstrate the capabilities of the operational strategies towards an increased dispatchability and plant economic effectiveness. The analysis shows that different strategies may lead to significant differences in the plant annual production, expected economic incomes, number of power block stops, mean efficiency, etc. Specifically, it has been found that the economic incomes of a plant can be increased (+1.3%) even with a decreased total energy production (-1.5%) if the production is scheduled to follow a demand/price curve. Also, dramatic reduction in the number of turbine stops (-67%) can be achieved if the plant is operated towards this objective. The strategies presented in this study have not been optimized towards any specific objective, but only created to show the potential of well designed operational strategies in CSP plants. Therefore, many other strategies as well as optimized versions of the strategies explained below are possible and will be analyzed in future works.

  8. Two Thermoeconomic Diagnosis Methods Applied to Representative Operating Data of a Commercial Transcritical Refrigeration Plant

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Sigthorsson, Oskar; Elmegaard, Brian

    2017-01-01

    In order to investigate options for improving the maintenance protocol of commercial refrigeration plants, two thermoeconomic diagnosis methods were evaluated on a state-of-the-art refrigeration plant. A common relative indicator was proposed for the two methods in order to directly compare the q...

  9. Operation of Finnish nuclear power plants. Quarterly report, 3rd quarter 1996

    Energy Technology Data Exchange (ETDEWEB)

    Sillanpaeae, T. [ed.

    1997-02-01

    Quarterly Reports on the operation of Finnish nuclear power plants describe events and observations relating to nuclear and radiation safety which the Finnish Centre for Radiation and Nuclear Safety (STUK) considers safety significant. Safety improvements at the plants are also described. The Report also includes a summary of the radiation safety of plant personnel and of the environment and tabulated data on the plants` production and load factors. In the third quarter of 1996, the Finnish nuclear power plant units were in power operation except for the annual maintenance outages of Loviisa plant units and a shutdown at Olkiluoto 1 to identify and repair malfunctions of a high pressure turbine control valve. The load factor average of all plant units was 77.2%. Events in the third quarter of 1996 were classified level 0 on the International Nuclear Event Scale. Occupational doses and radioactive releases off-site were below authorised limits. Radioactive substances were measurable in samples collected around the plants in such quantities only as have no bearing on the radiation exposure of the population. The names of Teollisuuden Voima Oy`s plant units have changed. Olkiluoto 1 and Olkiluoto 2 now replace the names TVO I and TVO II previously used in quarterly reports. (orig.).

  10. Inventory of power plants in the United States as of January 1, 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    The Inventory of Power Plants in the United States provides annual statistics on generating units operated by electric utilities in the United States (the 50 States and the District of Columbia). Statistics presented in this report reflect the status of generating units as of January 1, 1996. The publication also provides a 10-year outlook for generating unit additions. This report is prepared annually by the Coal and Electric Data and Renewables Division; Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); U.S. Department of Energy (DOE). Data summarized in this report are useful to a wide audience including Congress; Federal and State agencies; the electric utility industry; and the general public. Data presented in this report were assembled and published by the EIA to fulfill its data collection and dissemination responsibilities as specified in the Federal Energy Administration Act of 1974 as amended.

  11. Inventory of power plants in the United States as of January 1, 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    The Inventory of Power Plants in the United States provides annual statistics on generating units operated by electric utilities in the United States (the 50 States and the District of Columbia). Statistics presented in this report reflect the status of generating units as of January 1, 1997. The publication also provides a 10-yr outlook for generating unit additions. This report is prepared annually by the Coal and Electric Data and Renewables Division; Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); U.S. Department of Energy (DOE). Data summarized in this report are useful to a wide audience including Congress; Federal and State agencies; the electric utility industry; and the general public. Data presented in this report were assembled and published by the EIA to fulfill its data collection and dissemination responsibilities as specified in the Federal Energy Administration Act of 1974 (Public Law 93-275) as amended.

  12. Principles of Design And Operations Of Wastewater Treatment Pond Systems For Plant Operators, Engineers, And Managers

    Science.gov (United States)

    Wastewater pond systems provide reliable, low cost, and relatively low maintenance treatment for municipal and industrial discharges. However, they do have certain design, operations, and maintenance requirements. While the basic models have not changed in the 30-odd years sinc...

  13. Theoretical and experimental researches on the operating costs of a wastewater treatment plant

    Science.gov (United States)

    Panaitescu, M.; Panaitescu, F.-V.; Anton, I.-A.

    2015-11-01

    Purpose of the work: The total cost of a sewage plants is often determined by the present value method. All of the annual operating costs for each process are converted to the value of today's correspondence and added to the costs of investment for each process, which leads to getting the current net value. The operating costs of the sewage plants are subdivided, in general, in the premises of the investment and operating costs. The latter can be stable (normal operation and maintenance, the establishment of power) or variables (chemical and power sludge treatment and disposal, of effluent charges). For the purpose of evaluating the preliminary costs so that an installation can choose between different alternatives in an incipient phase of a project, can be used cost functions. In this paper will be calculated the operational cost to make several scenarios in order to optimize its. Total operational cost (fixed and variable) is dependent global parameters of wastewater treatment plant. Research and methodology: The wastewater treatment plant costs are subdivided in investment and operating costs. We can use different cost functions to estimate fixed and variable operating costs. In this study we have used the statistical formulas for cost functions. The method which was applied to study the impact of the influent characteristics on the costs is economic analysis. Optimization of plant design consist in firstly, to assess the ability of the smallest design to treat the maximum loading rates to a given effluent quality and, secondly, to compare the cost of the two alternatives for average and maximum loading rates. Results: In this paper we obtained the statistical values for the investment cost functions, operational fixed costs and operational variable costs for wastewater treatment plant and its graphical representations. All costs were compared to the net values. Finally we observe that it is more economical to build a larger plant, especially if maximum loading

  14. U.S. Nuclear Power Plant Operating Cost and Experience Summaries

    Energy Technology Data Exchange (ETDEWEB)

    Reid, RL

    2003-09-18

    The ''U.S. Nuclear Power Plant Operating Cost and Experience Summaries'' (NUREG/CR-6577, Supp. 2) report has been prepared to provide historical operating cost and experience information on U.S. commercial nuclear power plants during 2000-2001. Costs incurred after initial construction are characterized as annual production costs, which represent fuel and plant operating and maintenance expenses, and capital expenditures related to facility additions/modifications, which are included in the plant capital asset base. As discussed in the report, annual data for these two cost categories were obtained from publicly available reports and must be accepted as having different degrees of accuracy and completeness. Treatment of inconclusive and incomplete data is discussed. As an aid to understanding the fluctuations in the cost histories, operations summaries for each nuclear unit are provided. The intent of these summaries is to identify important operating events; refueling, major maintenance, and other significant outages; operating milestones; and significant licensing or enforcement actions. Information used in the summaries is condensed from operating reports submitted by the licensees, the Nuclear Regulatory Commission (NRC) database for enforcement actions, and outage reports.

  15. Planning guide biomass conversion plants consisting of concrete. Planning, dimensioning and operation; Planungshilfe Biogasanlagen aus Beton. Planung, Bemessung, Ausfuehrung

    Energy Technology Data Exchange (ETDEWEB)

    Middel, Matthias (ed.)

    2013-08-01

    In recent years, the construction of biomass conversion plants for the production of clean energy experienced a boom. This boom will still continue for some years. The operation of biomass conversion plants imposes high demands on the construction. Simultaneously, the operators of biomass conversion plants expect a long trouble-free service life of their plants. Biogas plants consisting of concrete meet these requirements, if these are carefully planned and performed. The book under consideration provides the necessary expertise for this.

  16. Arsenic pilot plant operation and results:Weatherford, Oklahoma.

    Energy Technology Data Exchange (ETDEWEB)

    Aragon, Malynda Jo; Arora, H. (Narasimhan Consulting Services Inc., Phoenix, Arizona); Karori, Saqib (Narasimhan Consulting Services Inc., Phoenix, Arizona); Pathan, Sakib (Narasimhan Consulting Services Inc., Phoenix, Arizona)

    2007-05-01

    Narasimhan Consulting Services, Inc. (NCS), under a contract with the Sandia National Laboratories (SNL), designed and operated pilot scale evaluations of the adsorption and coagulation/filtration treatment technologies aimed at meeting the recently revised arsenic maximum contaminant level (MCL) for drinking water. The standard of 10 {micro}g/L (10 ppb) is effective as of January 2006. The pilot demonstration is a project of the Arsenic Water Technology Partnership program, a partnership between the American Water Works Association Research Foundation (AwwaRF), SNL and WERC (A Consortium for Environmental Education and Technology Development). The pilot evaluation was conducted at Well 30 of the City of Weatherford, OK, which supplies drinking water to a population of more than 10,400. Well water contained arsenic in the range of 16 to 29 ppb during the study. Four commercially available adsorption media were evaluated side by side for a period of three months. Both adsorption and coagulation/filtration effectively reduced arsenic from Well No.30. A preliminary economic analysis indicated that adsorption using an iron oxide media was more cost effective than the coagulation/ filtration technology.

  17. Safety analysis, 200 Area, Savannah River Plant: Separations area operations

    Energy Technology Data Exchange (ETDEWEB)

    Perkins, W.C.; Lee, R.; Allen, P.M.; Gouge, A.P.

    1991-07-01

    The nev HB-Line, located on the fifth and sixth levels of Building 221-H, is designed to replace the aging existing HB-Line production facility. The nev HB-Line consists of three separate facilities: the Scrap Recovery Facility, the Neptunium Oxide Facility, and the Plutonium Oxide Facility. There are three separate safety analyses for the nev HB-Line, one for each of the three facilities. These are issued as supplements to the 200-Area Safety Analysis (DPSTSA-200-10). These supplements are numbered as Sup 2A, Scrap Recovery Facility, Sup 2B, Neptunium Oxide Facility, Sup 2C, Plutonium Oxide Facility. The subject of this safety analysis, the, Plutonium Oxide Facility, will convert nitrate solutions of {sup 238}Pu to plutonium oxide (PuO{sub 2}) powder. All these new facilities incorporate improvements in: (1) engineered barriers to contain contamination, (2) barriers to minimize personnel exposure to airborne contamination, (3) shielding and remote operations to decrease radiation exposure, and (4) equipment and ventilation design to provide flexibility and improved process performance.

  18. Steady-state plant model to predict hydrogen levels in power plant components

    Science.gov (United States)

    Glatzmaier, Greg C.; Cable, Robert; Newmarker, Marc

    2017-06-01

    The National Renewable Energy Laboratory (NREL) and Acciona Energy North America developed a full-plant steady-state computational model that estimates levels of hydrogen in parabolic trough power plant components. The model estimated dissolved hydrogen concentrations in the circulating heat transfer fluid (HTF), and corresponding partial pressures within each component. Additionally for collector field receivers, the model estimated hydrogen pressure in the receiver annuli. The model was developed to estimate long-term equilibrium hydrogen levels in power plant components, and to predict the benefit of hydrogen mitigation strategies for commercial power plants. Specifically, the model predicted reductions in hydrogen levels within the circulating HTF that result from purging hydrogen from the power plant expansion tanks at a specified target rate. Our model predicted hydrogen partial pressures from 8.3 mbar to 9.6 mbar in the power plant components when no mitigation treatment was employed at the expansion tanks. Hydrogen pressures in the receiver annuli were 8.3 to 8.4 mbar. When hydrogen partial pressure was reduced to 0.001 mbar in the expansion tanks, hydrogen pressures in the receiver annuli fell to a range of 0.001 mbar to 0.02 mbar. When hydrogen partial pressure was reduced to 0.3 mbar in the expansion tanks, hydrogen pressures in the receiver annuli fell to a range of 0.25 mbar to 0.28 mbar. Our results show that controlling hydrogen partial pressure in the expansion tanks allows us to reduce and maintain hydrogen pressures in the receiver annuli to any practical level.

  19. Steady-State Plant Model to Predict Hydroden Levels in Power Plant Components

    Energy Technology Data Exchange (ETDEWEB)

    Glatzmaier, Greg C.; Cable, Robert; Newmarker, Marc

    2017-06-27

    The National Renewable Energy Laboratory (NREL) and Acciona Energy North America developed a full-plant steady-state computational model that estimates levels of hydrogen in parabolic trough power plant components. The model estimated dissolved hydrogen concentrations in the circulating heat transfer fluid (HTF), and corresponding partial pressures within each component. Additionally for collector field receivers, the model estimated hydrogen pressure in the receiver annuli. The model was developed to estimate long-term equilibrium hydrogen levels in power plant components, and to predict the benefit of hydrogen mitigation strategies for commercial power plants. Specifically, the model predicted reductions in hydrogen levels within the circulating HTF that result from purging hydrogen from the power plant expansion tanks at a specified target rate. Our model predicted hydrogen partial pressures from 8.3 mbar to 9.6 mbar in the power plant components when no mitigation treatment was employed at the expansion tanks. Hydrogen pressures in the receiver annuli were 8.3 to 8.4 mbar. When hydrogen partial pressure was reduced to 0.001 mbar in the expansion tanks, hydrogen pressures in the receiver annuli fell to a range of 0.001 mbar to 0.02 mbar. When hydrogen partial pressure was reduced to 0.3 mbar in the expansion tanks, hydrogen pressures in the receiver annuli fell to a range of 0.25 mbar to 0.28 mbar. Our results show that controlling hydrogen partial pressure in the expansion tanks allows us to reduce and maintain hydrogen pressures in the receiver annuli to any practical level.

  20. Progress Toward Steady-State Operation on Tore Supra

    Institute of Scientific and Technical Information of China (English)

    J. Jacquinot; G. T. Hoang; the Tore Supra Team

    2004-01-01

    Important technological and physics issues related to steady-state operation required for next step are being examined on Tore Supra, after a major upgrade of internal components in order to increase the heat extraction capability to 25 MW for 1000 s. Here, we show first experimental results, where all the plasma facing components were actively cooled during pulses exceeding four minutes, with reactor-relevant heat load. New physics was observed in non-inductively driven plasmas, including a stationary peaked radial profile of the plasma density generated by an anomalous inward pinch; and a regime characterized by sinusoidal oscillations of central electron temperature, governed by non-linear coupling between heat transport and plasma current analogous to a predator-prey mechanism.

  1. Solid state light source driver establishing buck or boost operation

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, Fred

    2017-08-29

    A solid state light source driver circuit that operates in either a buck convertor or a boost convertor configuration is provided. The driver circuit includes a controller, a boost switch circuit and a buck switch circuit, each coupled to the controller, and a feedback circuit, coupled to the light source. The feedback circuit provides feedback to the controller, representing a DC output of the driver circuit. The controller controls the boost switch circuit and the buck switch circuit in response to the feedback signal, to regulate current to the light source. The controller places the driver circuit in its boost converter configuration when the DC output is less than a rectified AC voltage coupled to the driver circuit at an input node. The controller places the driver circuit in its buck converter configuration when the DC output is greater than the rectified AC voltage at the input node.

  2. Skinner boxes for psychotics: operant conditioning at Metropolitan State Hospital.

    Science.gov (United States)

    Rutherford, Alexandra

    2003-01-01

    Between 1953 and 1965, Ogden Lindsley and his associates conducted free-operant research with psychiatric inpatients and normal volunteers at Metropolitan State Hospital in Waltham, Massachusetts. Their project, originally named "Studies in Behavior Therapy," was renamed "Harvard Medical School Behavior Research Laboratory" in 1955. This name change and its implications were significant. The role of the laboratory in the history of the relationship between the experimental analysis of behavior and applied behavior analysis is discussed. A case is made for viewing Lindsley's early work as foundational for the subfield of the experimental analysis of human behavior that formally coalesced in the early 1980s. The laboratory's work is also contextualized with reference to the psychopharmacological revolution of the 1950s. Finally, a four-stage framework for studying the historical and conceptual development of behavior analysis is proposed.

  3. Thermal-Hydraulic Analysis Tasks for ANAV NPPs in Support of Plant Operation and Control

    Directory of Open Access Journals (Sweden)

    F. Reventós

    2008-01-01

    Full Text Available Thermal-hydraulic analysis tasks aimed at supporting plant operation and control of nuclear power plants are an important issue for the Asociación Nuclear Ascó-Vandellòs (ANAV. ANAV is the consortium that runs the Ascó power plants (2 units and the Vandellòs-II power plant. The reactors are Westinghouse-design, 3-loop PWRs with an approximate electrical power of 1000 MW. The Technical University of Catalonia (UPC thermal-hydraulic analysis team has jointly worked together with ANAV engineers at different levels in the analysis and improvement of these reactors. This article is an illustration of the usefulness of computational analysis for operational support. The contents presented were operational between 1985 and 2001 and subsequently changed slightly following various organizational adjustments. The paper has two different parts. In the first part, it describes the specific aspects of thermal-hydraulic analysis tasks related to operation and control and, in the second part, it briefly presents the results of three examples of analyses that were performed. All the presented examples are related to actual situations in which the scenarios were studied by analysts using thermal-hydraulic codes and prepared nodalizations. The paper also includes a qualitative evaluation of the benefits obtained by ANAV through thermal-hydraulic analyses aimed at supporting operation and plant control.

  4. The Operator Training Simulator System for the Pebble Bed Modular Reactor (PBMR) Plant

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, Trevor [Pebble Bed Modular Reactor (Proprietary) Limited, Pebble House, Centurion (South Africa)], E-mail: trevor.dudley@pbmr.co.za; Villiers, Piet de; Bouwer, Werner [Pebble Bed Modular Reactor (Proprietary) Limited, Pebble House, Centurion (South Africa); Luh, Robert [GSE Systems, Inc., 7133 Rutherford Suite 200, Baltimore, MD 21244 (United States)

    2008-11-15

    The Pebble Bed Modular Reactor (PBMR) is a First of a Kind Engineering with respect to the over 200 new innovations used in the design. The PBMR technical design is an inherited modified design from an earlier design such as the German 15 MWe AVR (Arbeitsgemeinschaft Versuchs Reaktor) and the THTR-300 MWe Thorium High Temperature Reactor (THTR), which ran in Germany as a test and research facility for 20 years. This paper discusses the Operator Training Simulator System for the PBMR Demonstration Power Plant. The Operator Training Simulator System will be used for operator training and licensing of plant operators. Included in the discussion is an overview of the major elements of the Operator Training Simulator System, including some of the main functional areas.

  5. A review of state-of-the-art processing operations in coal preparation

    Institute of Scientific and Technical Information of China (English)

    Noble Aaron; Luttrell Gerald H.

    2015-01-01

    Coal preparation is an integral part of the coal commodity supply chain. This stage of post-mining, pre-utilization beneficiation uses low-cost separation technologies to remove unwanted mineral matter and moisture which hinder the value of the coal product. Coal preparation plants typically employ several parallel circuits of cleaning and dewatering operations, with each circuit designed to optimally treat a specific size range of coal. Recent innovations in coal preparation have increased the efficiency and capac-ity of individual unit operations while reinforcing the standard parallel cleaning approach. This article, which describes the historical influences and state-of-the-art design for the various coal preparation unit operations, is organized to distinguish between coarse/intermediate coal cleaning and fine/ultrafine coal cleaning. Size reduction, screening, classification, cleaning, dewatering, waste disposal unit operations are particularly highlighted, with a special focus on the U.S. design philosophy. Notable differences between the U.S. and international operations are described as appropriate.

  6. 火电厂锅炉运行故障诊断分析%Fault Diagnosis Analysis of Boiler Operation in Thermal Power Plant

    Institute of Scientific and Technical Information of China (English)

    解文强; 王侠

    2015-01-01

    锅炉系统在火电厂中,较容易出现故障,影响火电厂的运行性能.火电厂为了提高锅炉运行的质量水平,全面落实故障诊断措施的应用,改善锅炉运行的状态,进而满足火电厂的需求.因此,本文重点分析火电厂锅炉运行中的故障诊断.%In the operation of thermal power plant, the most important boiler structure provides sufficient power for thermal power plant. In the thermal power plant, the boiler system is prone to failure, which affects the operation per-formance of the thermal power plant. In order to improve the quality level of boiler operation, the thermal power plant fully implements the application of fault diagnosis measures, and improves the state of boiler operation, and thus meets the needs of the thermal power plant. Therefore, this paper focuses on the analysis of the fault diagnosis of boil-er operation in power plant.

  7. Classification of emotions by multivariate analysis and individual differences of nuclear power plant operators` emotion

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Naoko; Yoshimura, Seiichi [Central Research Inst. of Electric Power Industry, Tokyo (Japan)

    1999-03-01

    The purpose of this study is the development of a simulation model which expresses operators` emotion under plant emergency. This report shows the classification of emotions by multivariate analysis and investigation results conducted to clarify individual differences of activated emotion influenced by personal traits. Although a former investigation was conducted to classify emotions into five basic emotions proposed by Johnson-Laird, the basic emotions was not based on real data. For the development of more realistic and accurate simulation model, it is necessary to recognize basic emotion and to classify emotions into them. As a result of analysis by qualification method 3 and cluster analysis, four basic clusters were clarified, i.e., Emotion expressed towards objects, Emotion affected by objects, Pleasant emotion, and Surprise. Moreover, 51 emotions were ranked in the order according to their similarities in each cluster. An investigation was conducted to clarify individual differences in emotion process using 87 plant operators. The results showed the differences of emotion depending on the existence of operators` foresight, cognitive style, experience in operation, and consciousness of attribution to an operating team. For example, operators with low self-efficacy, short experience or low consciousness of attribution to a team, feel more intensive emotion under plant emergency and more affected by severe plant conditions. The model which can express individual differences will be developed utilizing and converting these data hereafter. (author)

  8. Engineering development of a digital replacement protection system at an operating US PWR nuclear power plant: Installation and operational experiences

    Energy Technology Data Exchange (ETDEWEB)

    Miller, M.H. [Duke Power Co., Seneca, SC (United States)

    1995-04-01

    The existing Reactor Protection Systems (RPSs) at most US PWRs are systems which reflect 25 to 30 year-old designs, components and manufacturing techniques. Technological improvements, especially in relation to modern digital systems, offer improvements in functionality, performance, and reliability, as well as reductions in maintenance and operational burden. The Nuclear power industry and the US nuclear regulators are poised to move forward with the issues that have slowed the transition to modern digital replacements for nuclear power plant safety systems. The electric utility industry is now more than ever being driven by cost versus benefit decisions. Properly designed, engineered, and installed digital systems can provide adequate cost-benefit and allow continued nuclear generated electricity. This paper describes various issues and areas related to an ongoing RPS replacement demonstration project which are pertinant for a typical US nuclear plant to consider cost-effective replacement of an aging analog RPS with a modern digital RPS. The following subject areas relative to the Oconee Nuclear Station ISAT{trademark} Demonstrator project are discussed: Operator Interface Development; Equipment Qualification; Validation and Verification of Software; Factory Testing; Field Changes and Verification Testing; Utility Operational, Engineering and Maintenance; Experiences with Demonstration System; and Ability to operate in parallel with the existing Analog RPS.

  9. A state of the art on primary side stress corrosion cracking in nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H. P.; Kim, J. S.; Han, J. H.; Lee, D. H.; Lim, Y. S.; Suh, J. H.; Hwang, S. S.; Hur, D. H

    1999-09-01

    A state of art on primary water stress corrosion cracking (PWSCC) of alloy 600 used as steam generator tubing of nuclear power plant and remedial action on the PWSCC were reviewed and analyzed. One of the major metallurgical factors which have effect on PWSCC is Cr carbide distribution. A semicontinuous intergranular Cr carbide distribution enhance PWSCC of alloy 600. PWSCC rate is reported to be reported to be proportional to exp(-50 cal/RT) {sigma}{sup 4}. PWSCC rate also increase with increase in hydrogen partial pressure from 0 to 150 ppm and then decreased with further increase in hydrogen partial pressure to 757 ppm. Development of PWSCC prediction technology which takes into account tubing material, fabrication process and operating history of steam generator is needed to manage PWSCC of domestic nuclear power plant. PWSCC has mainly occurred at expansion irregularities within tubesheet, expansion transitions, dented tube support plate intersections and transition and apex of U bend. Remedial actions to PWSCC are sleeving, plugging, temperature reduction, Ni plating, Ni sleeving, shot peening and steam generator replacement in worst case. Option to remedial actions depend on plant specific such as plant age, leak rate from primary to secondary, density and progression of PWSCC. Ni sleeving developed in Framatome seems to be a powerful method because it never subject to PWSCC. Remedial action should be developed and evaluated for possible PWSCC of domestic nuclear power plant. (author)

  10. Operation of Shared Systems via a Common Control System in a Multi-Modular Plant

    Directory of Open Access Journals (Sweden)

    Jia Qianqian

    2014-01-01

    Full Text Available Integral type reactors may need to be grouped to produce as much energy as a utility demands due to the small electrical output of an individual reactor. Sharing of systems among modules at a nuclear plant site is economically beneficial. Operation of systems shared between modules in a multi-modular plant is an issue never met in current NPPs, which may impact human performance. A design of operation of the shared systems via a common control system is presented as a technical approach to solve the problem. Modules and shared systems are controlled in independent network domains, respectively. Different from current NPPs, a limitation of operation authorities corresponding to certain modules and shared systems is defined to minimize the operation confusion between modules by one operator and to minimize the operation confusion of shared systems by different operators. Different characteristics of the shared system are analyzed, and different operation and control strategies are presented. An example is given as an application of the operation strategies. The operation design of the multi-modular system is in the preliminary stage, and, as an concept design, more verification and validation is needed in further works.

  11. 14 CFR Appendix A to Part 136 - Special Operating Rules for Air Tour Operators in the State of Hawaii

    Science.gov (United States)

    2010-01-01

    ... Appendix A to Part 136—Special Operating Rules for Air Tour Operators in the State of Hawaii Section 1... compensation or hire. “Air tour operator” means any person who conducts an air tour. Section 3. Helicopter... operator must complete a performance plan before each helicopter air tour flight. The performance plan...

  12. Method for Prediction of the Power Output from Photovoltaic Power Plant under Actual Operating Conditions

    Science.gov (United States)

    Obukhov, S. G.; Plotnikov, I. A.; Surzhikova, O. A.; Savkin, K. D.

    2017-04-01

    Solar photovoltaic technology is one of the most rapidly growing renewable sources of electricity that has practical application in various fields of human activity due to its high availability, huge potential and environmental compatibility. The original simulation model of the photovoltaic power plant has been developed to simulate and investigate the plant operating modes under actual operating conditions. The proposed model considers the impact of the external climatic factors on the solar panel energy characteristics that improves accuracy in the power output prediction. The data obtained through the photovoltaic power plant operation simulation enable a well-reasoned choice of the required capacity for storage devices and determination of the rational algorithms to control the energy complex.

  13. Waste to energy plant operation under the influence of market and legislation conditioned changes

    DEFF Research Database (Denmark)

    Tomic, Tihomir; Dominkovic, Dominik Franjo; Pfeifer, Antun

    2017-01-01

    In this paper, gate-fee changes of the waste-to-energy plants are investigated in the conditions set by European Union legislation and by the introduction of the new heat market. Waste management and sustainable energy supply are core issues of sustainable development of regions, especially urban...... areas. These two energy flows logically come together in the combined heat and power facility by waste incineration. However, the implementation of new legislation influences quantity and quality of municipal waste and operation of waste-to-energy systems. Once the legislation requirements are met......, waste-to-energy plants need to be adapted to market operation. This influence is tracked by the gate-fee volatility. The operation of the waste-to-energy plant on electricity markets is simulated by using EnergyPLAN and heat market is simulated in Matlab, based on hourly marginal costs. The results have...

  14. Nuclear power plant simulators: their use in operator training and requalification

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D.W.; Baer, D.K.; Francis, C.C.

    1980-07-01

    This report presents the results of a study performed for the Nuclear Regulatory Commission to evaluate the capabilities and use of nuclear power plant simulators either built or being built by the US nuclear power industry; to determine the adequacy of existing standards for simulator design and for the training of power plant operators on simulators; and to assess the issues about simulator training programs raised by the March 28, 1979, accident at Three Mile Island Unit 2.

  15. LONG TERM OPERATION ISSUES FOR ELECTRICAL CABLE SYSTEMS IN NUCLEAR POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    Fifield, Dr Leonard S [Pacific Northwest National Laboratory (PNNL); Duckworth, Robert C [ORNL; Glass III, Dr. Samuel W. [Pacific Northwest National Laboratory (PNNL)

    2016-01-01

    conditions, but extension of behavior to long term degradation under more mild conditions, such as those experienced by most installed cables in nuclear power plants, is complicated by the fact that different degradation mechanisms may be involved in extreme and mild scenarios. The discrepancy in predicted results from short term, more extreme exposure and actual results from longer term, more mild exposures can be counter intuitive. For instance, due to the attenuation of oxidation penetration in material samples rapidly aged through exposure to high temperatures, the bulk of the samples may be artificially protected from thermal aging. In another example, simultaneous exposure of cable insulation material to heat and radiation may actually lead to less damage at higher temperatures than may be observed at lower temperatures. The Light Water Reactor Sustainability program of the United States (US) Department of Energy Office (DOE) of Nuclear Energy is funding research to increase the predictive understanding of electrical cable material aging and degradation in existing nuclear power plants in support of continued safe operation of plants beyond their initial license periods. This research includes the evaluation and development of methods to assess installed cable condition.

  16. Variable Frequency Operations of an Offshore Wind Power Plant with HVDC-VSC: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Gevorgian, V.; Singh, M.; Muljadi, E.

    2011-12-01

    In this paper, a constant Volt/Hz operation applied to the Type 1 wind turbine generator. Various control aspects of Type 1 generators at the plant level and at the turbine level will be investigated. Based on DOE study, wind power generation may reach 330 GW by 2030 at the level of penetration of 20% of the total energy production. From this amount of wind power, 54 GW of wind power will be generated at offshore wind power plants. The deployment of offshore wind power plants requires power transmission from the plant to the load center inland. Since this power transmission requires submarine cable, there is a need to use High-Voltage Direct Current (HVDC) transmission. Otherwise, if the power is transmitted via alternating current, the reactive power generated by the cable capacitance may cause an excessive over voltage in the middle of the transmission distance which requires unnecessary oversized cable voltage breakdown capability. The use of HVDC is usually required for transmission distance longer than 50 kilometers of submarine cables to be economical. The use of HVDC brings another advantage; it is capable of operating at variable frequency. The inland substation will be operated to 60 Hz synched with the grid, the offshore substation can be operated at variable frequency, thus allowing the wind power plant to be operated at constant Volt/Hz. In this paper, a constant Volt/Hz operation applied to the Type 1 wind turbine generator. Various control aspects of Type 1 generators at the plant level and at the turbine level will be investigated.

  17. Initial assessment of the operability of the VHTR-HTSE nuclear hydrogen plant.

    Energy Technology Data Exchange (ETDEWEB)

    Vilim, R. B.; Nuclear Engineering Division

    2007-11-01

    The generation of hydrogen from nuclear power will need to compete on three fronts: production, operability, and safety to be viable in the energy marketplace of the future. This work addresses the operability of a coupled nuclear and hydrogen-generating plant while referring to other work for progress on production and safety. Operability is a measure of how well a plant can meet time-varying production demands while remaining within equipment limits. It can be characterized in terms of the physical processes that underlie operation of the plant. In this work these include the storage and transport of energy within components as represented by time constants and energy capacitances, the relationship of reactivity to temperature, and the coordination of heat generation and work production for a near-ideal gas working fluid. Criteria for assessing operability are developed and applied to the Very High Temperature Reactor coupled to the High Temperature Steam Electrolysis process, one of two DOE/INL reference plant concepts for hydrogen production. Results of preliminary plant control and stability studies are described. A combination of inventory control in the VHTR plant and flow control in the HTSE plant proved effective for maintaining hot-side temperatures near constant during quasi-static change in hydrogen production rate. Near constant electrolyzer outlet temperature is achieved by varying electrolyzer cell area to control cell joule heating. It was found that rates of temperature change in the HTSE plant for a step change in hydrogen production rate are largely determined by the thermal characteristics of the electrolyzer. It's comparatively large thermal mass and the presence of recuperative heat exchangers result in a tight thermal coupling of HTSE components to the electrolyzer. It was found that thermal transients arising in the chemical plant are strongly damped at the reactor resulting in a stable combined plant. The large Doppler reactivity

  18. Joint Operation of Several Types of Power Plants to Increasing Net Profit in Deregulated Power Market

    Directory of Open Access Journals (Sweden)

    S. Sajedi

    2012-03-01

    Full Text Available This study proposes joint operation of power plant and electric energy storage plant in order to maximizing overall profit in a restructured electricity market. The goal is investigating the coupling efficiency on profit increment considering various intensities of power plant’s fuel constraint. In order to reach this goal, the amount of overall profits of fuel-constrained power plant, battery plant and their coupling are first calculated in a specific time interval. Then, the coupling efficiency is determined using incremental profit rate. Having an appropriate strategy to calculate this parameter is essential. Hence, a comprehensive approach to selfschedule of individual and coupled plants is developed. This comprehensive self-scheduling approach is therefore formulated and solved as a Mixed Integer Non-linear Programming (MINLP problem. Numerical results for a case study are discussed.

  19. Precursor Report of Data Needs and Recommended Practices for PV Plant Availability Operations and Maintenance Reporting.

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Roger R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration; Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration; Balfour, John R. [High Performance PV, Phoenix, AZ (United States)

    2015-01-01

    Characterizing the factors that affect reliability of a photovoltaic (PV) power plant is an important aspect of optimal asset management. This document describes the many factors that affect operation and maintenance (O&M) of a PV plant, identifies the data necessary to quantify those factors, and describes how data might be used by O&M service providers and others in the PV industry. This document lays out data needs from perspectives of reliability, availability, and key performance indicators and is intended to be a precursor for standardizing terminology and data reporting, which will improve data sharing, analysis, and ultimately PV plant performance.

  20. Steady-state evaporator models of Solar Sea Power Plants. Part I

    Energy Technology Data Exchange (ETDEWEB)

    Hetyei, S. A.; Neuman, C. P.

    1976-08-01

    Previously, a methodology was developed for modeling the dynamic and steady-state behavior of Solar Sea Power Plants (SSPP). Here, the pertinent physical laws of heat transfer and mass balance are applied to develop a lumped parameter, steady-state model for tube-and-shell evaporators incorporating falling films. This model is analyzed to investigate the assumption of constant heat transfer coefficients in modeling the steady-state behavior of smooth-tube evaporators operated in the turbulent flow regime. It is concluded that, for all practical purposes, the local heat transfer coefficient on the working fluid side of the evaporator tube is constant for both fixed and +-10% changes in the inlet working fluid flow rate. The overall objective is to develop simulation models of a complete SSPP as tools of design and optimization.

  1. The effects of stress on nuclear power plant operational decision making and training approaches to reduce stress effects

    Energy Technology Data Exchange (ETDEWEB)

    Mumaw, R.J.

    1994-08-01

    Operational personnel may be exposed to significant levels of stress during unexpected changes in plant state an plant emergencies. The decision making that identifies operational actions, which is strongly determined by procedures, may be affected by stress, and performance may be impaired. ER report analyzes potential effects of stress in nuclear power plant (NPP) settings, especially in the context of severe accident management (SAM). First, potential sources of stress in the NPP setting are identified. This analysis is followed by a review of the ways in which stress is likely to affect performance, with an emphasis on performance of cognitive skills that are linked to operational decision making. Finally, potential training approaches for reducing or eliminating stress effects are identified. Several training approaches have the potential to eliminate or mitigate stress effects on cognitive skill performance. First, the use of simulated events for training can reduce the novelty and uncertainty that can lead to stress and performance impairments. Second, training to make cognitive processing more efficient and less reliant on attention and memory resources can offset the reductions in these resources that occur under stressful conditions. Third, training that targets crew communications skills can reduce the likelihood that communications will fail under stress.

  2. Characteristic operator functions for quantum input-plant-output models and coherent control

    Science.gov (United States)

    Gough, John E.

    2015-01-01

    We introduce the characteristic operator as the generalization of the usual concept of a transfer function of linear input-plant-output systems to arbitrary quantum nonlinear Markovian input-output models. This is intended as a tool in the characterization of quantum feedback control systems that fits in with the general theory of networks. The definition exploits the linearity of noise differentials in both the plant Heisenberg equations of motion and the differential form of the input-output relations. Mathematically, the characteristic operator is a matrix of dimension equal to the number of outputs times the number of inputs (which must coincide), but with entries that are operators of the plant system. In this sense, the characteristic operator retains details of the effective plant dynamical structure and is an essentially quantum object. We illustrate the relevance to model reduction and simplification definition by showing that the convergence of the characteristic operator in adiabatic elimination limit models requires the same conditions and assumptions appearing in the work on limit quantum stochastic differential theorems of Bouten and Silberfarb [Commun. Math. Phys. 283, 491-505 (2008)]. This approach also shows in a natural way that the limit coefficients of the quantum stochastic differential equations in adiabatic elimination problems arise algebraically as Schur complements and amounts to a model reduction where the fast degrees of freedom are decoupled from the slow ones and eliminated.

  3. Development of a Leading Performance Indicator from Operational Experience and Resilience in a Nuclear Power Plant

    Directory of Open Access Journals (Sweden)

    Pamela F. Nelson

    2016-02-01

    Full Text Available The development of operational performance indicators is of utmost importance for nuclear power plants, since they measure, track, and trend plant operation. Leading indicators are ideal for reducing the likelihood of consequential events. This paper describes the operational data analysis of the information contained in the Corrective Action Program. The methodology considers human error and organizational factors because of their large contribution to consequential events. The results include a tool developed from the data to be used for the identification, prediction, and reduction of the likelihood of significant consequential events. This tool is based on the resilience curve that was built from the plant's operational data. The stress is described by the number of unresolved condition reports. The strain is represented by the number of preventive maintenance tasks and other periodic work activities (i.e., baseline activities, as well as, closing open corrective actions assigned to different departments to resolve the condition reports (i.e., corrective action workload. Beyond the identified resilience threshold, the stress exceeds the station's ability to operate successfully and there is an increased likelihood that a consequential event will occur. A performance indicator is proposed to reduce the likelihood of consequential events at nuclear power plants.

  4. OPERATIONAL EARTHQUAKE FORECASTING. State of Knowledge and Guidelines for Utilization

    Directory of Open Access Journals (Sweden)

    Koshun Yamaoka

    2011-08-01

    Full Text Available Following the 2009 L'Aquila earthquake, the Dipartimento della Protezione Civile Italiana (DPC, appointed an International Commission on Earthquake Forecasting for Civil Protection (ICEF to report on the current state of knowledge of short-term prediction and forecasting of tectonic earthquakes and indicate guidelines for utilization of possible forerunners of large earthquakes to drive civil protection actions, including the use of probabilistic seismic hazard analysis in the wake of a large earthquake. The ICEF reviewed research on earthquake prediction and forecasting, drawing from developments in seismically active regions worldwide. A prediction is defined as a deterministic statement that a future earthquake will or will not occur in a particular geographic region, time window, and magnitude range, whereas a forecast gives a probability (greater than zero but less than one that such an event will occur. Earthquake predictability, the degree to which the future occurrence of earthquakes can be determined from the observable behavior of earthquake systems, is poorly understood. This lack of understanding is reflected in the inability to reliably predict large earthquakes in seismically active regions on short time scales. Most proposed prediction methods rely on the concept of a diagnostic precursor; i.e., some kind of signal observable before earthquakes that indicates with high probability the location, time, and magnitude of an impending event. Precursor methods reviewed here include changes in strain rates, seismic wave speeds, and electrical conductivity; variations of radon concentrations in groundwater, soil, and air; fluctuations in groundwater levels; electromagnetic variations near and above Earth's surface; thermal anomalies; anomalous animal behavior; and seismicity patterns. The search for diagnostic precursors has not yet produced a successful short-term prediction scheme. Therefore, this report focuses on operational

  5. Evaluation of Biodiesel Fuels to Reduce Fossil Fuel Use in Corps of Engineers Floating Plant Operations

    Science.gov (United States)

    2016-07-01

    ER D C/ CH L TR -1 6- 11 Dredging Operations and Environmental Research Program Evaluation of Biodiesel Fuels to Reduce Fossil Fuel Use...Fuels to Reduce Fossil Fuel Use in Corps of Engineers Floating Plant Operations Michael Tubman and Timothy Welp Coastal and Hydraulics Laboratory...sensitive emissions, increase use of renewable energy, and reduce the use of fossil fuels was conducted with funding from the U.S. Army Corps of

  6. Use Of Probabilistic Risk Assessment (PRA) In Expert Systems To Advise Nuclear Plant Operators And Managers

    Science.gov (United States)

    Uhrig, Robert E.

    1988-03-01

    The use of expert systems in nuclear power plants to provide advice to managers, supervisors and/or operators is a concept that is rapidly gaining acceptance. f2 Generally, expert systems rely on the expertise of human experts or knowledge that has been codified in publications, books, or regulations to provide advice under a wide variety of conditions. In this work, a probabilistic risk assessment (PRA)3 of a nuclear power plant performed previously is used to assess the safety status of nuclear power plants and to make recommendations to the plant personnel. Nuclear power plants have many redundant systems and can continue to operate when one or more of these systems is disabled or removed from service for maintenance or testing. PRAs provide a means of evaluating the risk to the public associated with the operation of nuclear power plants with components or systems out of service. While the choice of the "source term" and methodology in a PRA may influence the absolute probability and consequences of a core melt, the ratio of two PRA calculations for two configurations of the same plant, carried out on a consistent basis, can readily identify the increase in risk associated with going from one configuration to the other. PRISIM,4 a personal computer program to calculate the ratio of core melt probabilities described above (based on previously performed PRAs), has been developed under the sponsorship of the U.S. Nuclear Regulatory Commission (NRC). When one or several components are removed from service, PRISM then calculates the ratio of the core melt probabilities. The inference engine of the expert system then uses this ratio and a constant risk criterion,5 along with information from its knowledge base (which includes information from the PRA), to advise plant personnel as to what action, if any, should be taken.

  7. In vitro propagation of plant virus using different forms of plant tissue culture and modes of culture operation.

    Science.gov (United States)

    Shih, Sharon M-H; Doran, Pauline M

    2009-09-10

    Plant virus accumulation was investigated in vitro using three different forms of plant tissue culture. Suspended cells, hairy roots and shooty teratomas of Nicotiana benthamiana were infected with tobacco mosaic virus (TMV) using the same initial virus:biomass ratio. Viral infection did not affect tissue growth or morphology in any of the three culture systems. Average maximum virus concentrations in hairy roots and shooty teratomas were similar and about an order of magnitude higher than in suspended cells. Hairy roots were considered the preferred host because of their morphological stability in liquid medium and relative ease of culture. The average maximum virus concentration in the hairy roots was 0.82+/-0.14 mg g(-1) dry weight; viral coat protein represented a maximum of approximately 6% of total soluble protein in the biomass. Virus accumulation in hairy roots was investigated further using different modes of semi-continuous culture operation aimed at prolonging the root growth phase and providing nutrient supplementation; however, virus concentrations in the roots were not enhanced compared with simple batch culture. The relative infectivity of virus in the biomass declined by 80-90% during all the cultures tested, irrespective of the form of plant tissue used or mode of culture operation. Hairy root cultures inoculated with a transgenic TMV-based vector in batch culture accumulated green fluorescent protein (GFP); however, maximum GFP concentrations in the biomass were relatively low at 39 microg g(-1) dry weight, probably due to genetic instability of the vector. This work highlights the advantages of using hairy roots for in vitro propagation of TMV compared with shooty teratomas and suspended plant cells, and demonstrates that batch root culture is more effective than semi-continuous operations for accumulation of high virus concentrations in the biomass.

  8. Operation of the Pinellas Plant Child Development Center/Partnership School: Environmental assessment

    Energy Technology Data Exchange (ETDEWEB)

    1990-07-20

    The US Department of Energy Albuquerque Operations Office (DOE/AL), through the DOE Pinellas Area Office (PAO) and GE Neutron Devices (GEND), is proposing a joint venture to operate a Partnership School and Child Development Center at the Pinellas Plant. The Child Development Center/Partnership School proposal has been developed. The building has been constructed, teachers and staff selected, and the building made ready for immediate occupancy. The proposed action addressed by this environmental assessment is the operation and utilization of the school as a Partnership School, a preschool Child Development Center, and a before- and after-hours child care facility. In compliance with the National Environmental Policy Act of 1970, the potential impacts from the operation of the proposed action are assessed. Additionally, since the proposed school is located next to an industrial facility, impacts on the school population from routine plant operations, as well as abnormal events, are analyzed, and changes in plant operation that may be prudent are considered. 25 refs., 8 figs., 9 tabs.

  9. Operation of the Pinellas Plant Child Development Center/Partnership School: Environmental assessment

    Energy Technology Data Exchange (ETDEWEB)

    1990-07-20

    The US Department of Energy Albuquerque Operations Office (DOE/AL), through the DOE Pinellas Area Office (PAO) and GE Neutron Devices (GEND), is proposing a joint venture to operate a Partnership School and Child Development Center at the Pinellas Plant. The Child Development Center/Partnership School proposal has been developed. The building has been constructed, teachers and staff selected, and the building made ready for immediate occupancy. The proposed action addressed by this environmental assessment is the operation and utilization of the school as a Partnership School, a preschool Child Development Center, and a before- and after-hours child care facility. In compliance with the National Environmental Policy Act of 1970, the potential impacts from the operation of the proposed action are assessed. Additionally, since the proposed school is located next to an industrial facility, impacts on the school population from routine plant operations, as well as abnormal events, are analyzed, and changes in plant operation that may be prudent are considered. 25 refs., 8 figs., 9 tabs.

  10. Safety significance of inadvertent operation of motor operated valves in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Ruger, C.J.; Higgins, J.C.; Carbonaro, J.F.; Hall, R.E.

    1994-05-01

    This report addresses concerns about the consequences of valve mispositioning which were brought to the forefront following an event at Davis Besse in 1985 (NRC, 1985a). The concern related to the ability to reposition ``position changeable`` motor operated valves (MOVs) in the event of their inadvertent operation from the control room and was documented in Nuclear Regulatory Commission (NRC) Bulletin 85-03 (NRC, 1985b) and Generic Letter (GL) 89-10 (NRC, 1989). The mispositioned MOVs may not be able to be returned to their required position due to high differential pressure (dP) or high flow conditions across the valves. The inability to reposition such valves may have significant safety consequences as in the Davis Besse event. However, full consideration of such mispositioning in safety analyses and in MOV test programs can be labor intensive and expensive. Industry raised concerns that consideration of position changeable valves under GL 89-10 would not decrease the probability of core damage to an extent which would justify licensee costs. As a response, Brookhaven National Laboratory (BNL) has conducted separate scoping studies for both Boiling Water Reactors (BWRS) and Pressurized Water Reactors (PWRs) using Probabilistic Risk Assessment (PRA) techniques to determine if such valve mispositioning by itself is significant to safety. The approach utilized internal events PRA models to survey the order of magnitude of the risk significance of valve mispositioning by considering the failure of selected position changeable MOVS. The change in core damage frequency (CDF) was determined for each valve considered and the results were presented as a risk increase ratio for each of four assumed MOV failure rates. The risk increase ratios resulting from this failure rate sensitivity study can be used as a basis for a judgement determination of the risk significance of the MOV mispositioning issue for BWRs and PWRS.

  11. Ensuring Operational Readiness: Private Military Contractor Support for the United States Air Force

    Science.gov (United States)

    2017-03-15

    Ensuring Operational Readiness: Private Military Contractor Support for the United States Air Force A Monograph by Maj Stephen P. Joca United...States Air Force School of Advanced Military Studies United States Army Command and General Staff College Fort Leavenworth, Kansas 2017 Approved...Operational Readiness: Private Military Contractor Support for the United States Air Force Approved by: __________________________________, Monograph

  12. A method for risk informing procedures at operating nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, P. F.; Martin del Campo, C., E-mail: pnelson_007@yahoo.com [UNAM, Facultad de Ingenieria, Departamento de Sistemas Energeticos, Paseo Cuauhnahuac No. 8532, Col. Progreso, 62550 Jiutepec, Morelos (Mexico)

    2012-10-15

    The technical approach presented establishes a framework intended to provide the necessary elements for a deployable human performance monitoring program that incorporates insights from plant specific probabilistic risk assessments, human reliability analysis, as well as the development of plant specific human failure data. A human performance monitoring program of this structure would be used to provide the ability to risk inform procedures (e.g., operations or maintenance) to determine the operational risk significance of procedural performance (i.e., precautions, prerequisites, procedure steps), the likelihood of consequential human error dur the performance of the procedure, and the identification of procedure specific barriers to reduce or eliminate consequential human errors. The program would provide the means to assess procedures prior to execution and the means to record and trend human failure events leading to a plant specific human failure database for human activities characterized as pre-initiator. The technical methods and data processing for each of these areas are developed and presented, as well as an example application of an operational procedure error leading to a plant level event (i.e, plant trip). (Author)

  13. State estimation of an acid gas removal (AGR) plant as part of an integrated gasification combined cycle (IGCC) plant with CO2 capture

    Energy Technology Data Exchange (ETDEWEB)

    Paul, P.; Bhattacharyya, D.; Turton, R.; Zitney, S.

    2012-01-01

    An accurate estimation of process state variables not only can increase the effectiveness and reliability of process measurement technology, but can also enhance plant efficiency, improve control system performance, and increase plant availability. Future integrated gasification combined cycle (IGCC) power plants with CO2 capture will have to satisfy stricter operational and environmental constraints. To operate the IGCC plant without violating stringent environmental emission standards requires accurate estimation of the relevant process state variables, outputs, and disturbances. Unfortunately, a number of these process variables cannot be measured at all, while some of them can be measured, but with low precision, low reliability, or low signal-to-noise ratio. As a result, accurate estimation of the process variables is of great importance to avoid the inherent difficulties associated with the inaccuracy of the data. Motivated by this, the current paper focuses on the state estimation of an acid gas removal (AGR) process as part of an IGCC plant with CO2 capture. This process has extensive heat and mass integration and therefore is very suitable for testing the efficiency of the designed estimators in the presence of complex interactions between process variables. The traditional Kalman filter (KF) (Kalman, 1960) algorithm has been used as a state estimator which resembles that of a predictor-corrector algorithm for solving numerical problems. In traditional KF implementation, good guesses for the process noise covariance matrix (Q) and the measurement noise covariance matrix (R) are required to obtain satisfactory filter performance. However, in the real world, these matrices are unknown and it is difficult to generate good guesses for them. In this paper, use of an adaptive KF will be presented that adapts Q and R at every time step of the algorithm. Results show that very accurate estimations of the desired process states, outputs or disturbances can be

  14. The Future of Information Operations in the United States Army

    Science.gov (United States)

    2007-01-01

    as Marketing Marketing tools and concepts could generate support for coalition military operations just as an advertiser promoting a commercial...military, the advanced application of marketing tools to leverage humanitarian assistance and public affairs within an Information Operations plan

  15. GRAPHICAL REPRESENTATIONS OF 1991 STEAM-ELECTRIC POWER PLANT OPERATION AND AIR EMISSIONS DATA

    Science.gov (United States)

    The report provides graphical representations of data derived from the U.S. Department of Energy's (DOE's) Energy Information Administration, s Form EIA-767 (Steam Electric Plant Operation and Design Report). or more than 10 years, EIA has collected monthly boiler level data from...

  16. Operational flexibility and economics of power plants in future low-carbon power systems

    NARCIS (Netherlands)

    Brouwer, Anne Sjoerd|info:eu-repo/dai/nl/330822748; van den Broek, Machteld|info:eu-repo/dai/nl/092946895; Seebregts, Ad; Faaij, André

    2015-01-01

    Future power systems will require large shares of low-carbon generators such as renewables and power plants with Carbon Capture and Storage (CCS) to keep global warming below 2. °C. Intermittent renewables increase the system-wide demand for flexibility and affect the operation of thermal power plan

  17. Development of a Water Treatment Plant Operation Manual Using an Algorithmic Approach.

    Science.gov (United States)

    Counts, Cary A.

    This document describes the steps to be followed in the development of a prescription manual for training of water treatment plant operators. Suggestions on how to prepare both flow and narrative prescriptions are provided for a variety of water treatment systems, including: raw water, flocculation, rapid sand filter, caustic soda feed, alum feed,…

  18. Ergodynamics in the Reliability of Power Plant Operators and Prospective Hybrid Intelligence Systems.

    Science.gov (United States)

    Venda; Chachko

    1996-01-01

    Based on ergodynamics and the hybrid intelligence theory, an analysis of the nuclear power plant operator's performance is given at the levels of strategies, tactics, and actions. Special attention is paid to the strategies used in the course of severe accidents at nuclear power plants. Data from Ukrainian and Russian power plants and training centres, and from accidents around the world were collected and processed. It is shown that in an emergency it is essential for the human operator to be flexible. This flexibility includes two main training and personal factors: a large set of strategies and tactics the operator manages to use, and quick transformations between the strategies (tactics). It was also found that some emergency tasks are too complicated: They require simultaneous use of different strategies, with time strictly limited by nuclear power plant dynamics. Those tasks cannot be successfully solved by any individual operator. Hybrid intelligence systems involving different specialists should be used in those cases in order to avoid failures in emergency problem solving and macroergonomic organizational design.

  19. Operational flexibility and economics of power plants in future low-carbon power systems

    NARCIS (Netherlands)

    Brouwer, Anne Sjoerd|info:eu-repo/dai/nl/330822748; van den Broek, Machteld|info:eu-repo/dai/nl/092946895; Seebregts, Ad; Faaij, André

    2015-01-01

    Future power systems will require large shares of low-carbon generators such as renewables and power plants with Carbon Capture and Storage (CCS) to keep global warming below 2. °C. Intermittent renewables increase the system-wide demand for flexibility and affect the operation of thermal power

  20. 75 FR 73135 - Southern Nuclear Operating Company, Inc. Joseph M. Farley Nuclear Plant, Environmental Assessment...

    Science.gov (United States)

    2010-11-29

    ... licensee), for operation of the Joseph M. Farley Nuclear Plant, Units 1 and 2 (FNP), located in Houston... the FNP from the required implementation date of March 31, 2010, for several new requirements of 10 CFR Part 73. Specifically, FNP would be granted an exemption from being in full compliance...

  1. 75 FR 19428 - Palisades Nuclear Plant; Notice of Consideration of Issuance of Amendment to Facility Operating...

    Science.gov (United States)

    2010-04-14

    ... COMMISSION Palisades Nuclear Plant; Notice of Consideration of Issuance of Amendment to Facility Operating License, Proposed No Significant Hazards Consideration Determination, and Opportunity for a Hearing The U... significant hazards consideration. Under the Commission's regulations in Title 10 of the Code of...

  2. 75 FR 70708 - Palisades Nuclear Plant; Notice of Consideration of Issuance of Amendment to Facility Operating...

    Science.gov (United States)

    2010-11-18

    ... COMMISSION Palisades Nuclear Plant; Notice of Consideration of Issuance of Amendment to Facility Operating License, Proposed No Significant Hazards Consideration Determination, and Opportunity for a Hearing The U... no significant hazards consideration. Under the Commission's regulations in Title 10 of the Code...

  3. Development of a Water Treatment Plant Operation Manual Using an Algorithmic Approach.

    Science.gov (United States)

    Counts, Cary A.

    This document describes the steps to be followed in the development of a prescription manual for training of water treatment plant operators. Suggestions on how to prepare both flow and narrative prescriptions are provided for a variety of water treatment systems, including: raw water, flocculation, rapid sand filter, caustic soda feed, alum feed,…

  4. Reducing water freshwater consumption at coal-fired power plants : approaches used outside the United States.

    Energy Technology Data Exchange (ETDEWEB)

    Elcock, D. (Environmental Science Division)

    2011-05-09

    Coal-fired power plants consume huge quantities of water, and in some water-stressed areas, power plants compete with other users for limited supplies. Extensive use of coal to generate electricity is projected to continue for many years. Faced with increasing power demands and questionable future supplies, industries and governments are seeking ways to reduce freshwater consumption at coal-fired power plants. As the United States investigates various freshwater savings approaches (e.g., the use of alternative water sources), other countries are also researching and implementing approaches to address similar - and in many cases, more challenging - water supply and demand issues. Information about these non-U.S. approaches can be used to help direct near- and mid-term water-consumption research and development (R&D) activities in the United States. This report summarizes the research, development, and deployment (RD&D) status of several approaches used for reducing freshwater consumption by coal-fired power plants in other countries, many of which could be applied, or applied more aggressively, at coal-fired power plants in the United States. Information contained in this report is derived from literature and Internet searches, in some cases supplemented by communication with the researchers, authors, or equipment providers. Because there are few technical, peer-reviewed articles on this topic, much of the information in this report comes from the trade press and other non-peer-reviewed references. Reducing freshwater consumption at coal-fired power plants can occur directly or indirectly. Direct approaches are aimed specifically at reducing water consumption, and they include dry cooling, dry bottom ash handling, low-water-consuming emissions-control technologies, water metering and monitoring, reclaiming water from in-plant operations (e.g., recovery of cooling tower water for boiler makeup water, reclaiming water from flue gas desulfurization [FGD] systems), and

  5. More efficient operation of coal fired power plants using nonlinear models

    Energy Technology Data Exchange (ETDEWEB)

    Bulsari, A.; Wemberg, A.; Anttila, A.; Multas, A. [Nonlinear Solution Oy, Turku (Finland)

    2010-07-15

    Abstract: Coal fired power plants should be operated in such a way that the emissions are kept clearly below desired limits and the combustion efficiency is as high as can be achieved. This requires a lot of quantitative knowledge of the effects of the process variables and fuel characteristics on the emissions and efficiency. Mathematical models can be developed with different approaches. Physical models are too slow to be used for on-line process guidance, and require too many assumptions and simplifications. It is feasible to develop empirical or semi-empirical models from normal production data of the power plant. This technical communication explains with an example of a coal fired power plant how nonlinear models are an effective means of determining the best operating conditions at any given load for a given type of coal.

  6. Operating experiences of the TESC BWE filter in the Escatron PFBC power plant

    Energy Technology Data Exchange (ETDEWEB)

    Tejedor, A.; Guilarte, R.; Nales, T.; Abellanal, I.

    1999-07-01

    A Ceramic Filter based on the TESC (Two Ends Supported Candle) concept by BWE has been operating since November 1997 at the 71 MWe Escatron PFBC Power Plant of ENDESA S.A. The Ceramic Filter is treating 1/9 of the combustion gases (this is 10.5 Kg/s), replacing a secondary cyclone, at temperatures ranging 750--820 C. The aim of this Project is to demonstrate the performance of a Ceramic Filter based on the TESC system, which keeps the ceramic elements working on compression by a pneumatic supporting system. The Escatron PFBC plant burns local lignites working under commercial conditions, and the objective is to optimize the main filtration parameters for these coals. The operating experience will permit evaluation of the design, the prediction of life expectancy of the materials used, while carrying out the tests needed to define commercial operating parameters. At present (December 1998) 4,420 hours of operation have been logged, 2,300 hours through the Ceramic Filter (mainly at full load) and the rest through a bypass cyclone system. The longest continuous Filter run lasted 687 hours, while the average run duration at the present test period is around 500 hours. Some problems regarding massive ash bridging due to the extremely sticky nature of the ash have been the main operating problem. Nevertheless, the operating results together with the very few candle failures (only in two of the runs) have proved that the TESC concept is right and a promising way to commercial hot gas filtration units. This paper describes the Escatron Filter Plant and reviews the operation experiences of the TESC Ceramic Filter at 71 MWe Escatron PFBC Plant.

  7. The role of a multiagent organization in the management of nuclear plants operational objectives

    Energy Technology Data Exchange (ETDEWEB)

    Papin, B.; Arnaud, G.; Fiche, Ch.; Dumas, M.

    1998-07-01

    The aim of the ESCRIME project, now reaching conclusions, was to optimize the collaboration between plant operators and computerized systems for the management of plant safety and availability. The requirement for putting such a collaboration into effective application was to clarify the operational strategies in order to enable a dialog between men and systems based on a ''shared representation'' of the plant operation. Thus a new vision of this operation, focusing on the completion of the plant fundamental objectives has been defined. This so-called means-ends strategy enables the simultaneous management of these objectives and provides explicit rules (priority...) to solve eventual conflicts (Physical interaction, sharing of resources...) apt to occur. The direct implementation of such strategies by the operators, using a dedicated man/machine interface, has made the object of the second phase of the ESCRIME project, already presented in LOEN in 1996. The third phase of the program, more prospective, aimed at finding an efficient way of sharing the management of plant objectives between the operator(s) and ''intelligent controllers'', preserving the role of the man in the decision loop and enabling him to maintain his awareness about the evolution of the plant. The multiagent organization has been identified as a promising way of sharing executive and decisive tasks between human and computerized agents. This organization, based on explicit ''social'' rules managing the negotiation between autonomous agents, appeared quite perfectly adapted to the management of conflicting objectives like in the means - ends strategy. The main problem to solve was, in fact, to check whether humans could be brought under this social organization in such a way as they could communicate and negotiate efficiently with the computerized agents. After a brief recall of the principles of the means - ends strategy for plant

  8. Estimating Climate Trends: Application to United States Plant Hardiness Zones

    Directory of Open Access Journals (Sweden)

    Nir Y. Krakauer

    2012-01-01

    Full Text Available The United States Department of Agriculture classifies plant hardiness zones based on mean annual minimum temperatures over some past period (currently 1976–2005. Since temperatures are changing, these values may benefit from updating. I outline a multistep methodology involving imputation of missing station values, geostatistical interpolation, and time series smoothing to update a climate variable’s expected value compared to a climatology period and apply it to estimating annual minimum temperature change over the coterminous United States. I show using hindcast experiments that trend estimation gives more accurate predictions of minimum temperatures 1-2 years in advance compared to the previous 30 years’ mean alone. I find that annual minimum temperature increased roughly 2.5 times faster than mean temperature (~2.0 K versus ~0.8 K since 1970, and is already an average of 1.2  0.5 K (regionally up to ~2 K above the 1976–2005 mean, so that much of the country belongs to warmer hardiness zones compared to the current map. The methods developed may also be applied to estimate changes in other climate variables and geographic regions.

  9. Construction and operation of an industrial solid waste landfill at Portsmouth Gaseous Diffusion Plant, Piketon, Ohio

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The US Department of Energy (DOE), Office of Waste Management, proposes to construct and operate a solid waste landfill within the boundary of the Portsmouth Gaseous Diffusion Plant (PORTS), Piketon, Ohio. The purpose of the proposed action is to provide PORTS with additional landfill capacity for non-hazardous and asbestos wastes. The proposed action is needed to support continued operation of PORTS, which generates non-hazardous wastes on a daily basis and asbestos wastes intermittently. Three alternatives are evaluated in this environmental assessment (EA): the proposed action (construction and operation of the X-737 landfill), no-action, and offsite shipment of industrial solid wastes for disposal.

  10. Predicting the operation performance of condensate polishing plant using a mathematical kinetic model

    Energy Technology Data Exchange (ETDEWEB)

    Handy, B.J.; Greene, J.C. [NNC Solutions Ltd, Warrington (United Kingdom)

    2004-09-01

    NNC limited provides an ion exchange resin technology facility, which includes a resin testing service. A range of ion exchange resin properties is measured and this includes ion exchange capacity, resin bead particle sizes and anion kinetic performance in terms of mass transfer coefficients. It has long been considered by the authors that the experimental data for resins taken from operating condensate polishing plant (CPP) could be used to predict the expected plant performance. This has now been realised with the development of a mathematical model which predicts CPP behaviour using appropriate experimentally derived parameters and plant design data. Modelling methods for the separate anion and cation components of a mixed bed were initially developed before the mixed bed as a whole was addressed. Initially, an analytical approach was adopted, which proved successful for simple cases. For more complex examples a numerical approach was developed and found to be more suitable. The paper describes the development of anion and cation bed models, and a mixed bed model. In the latter model, the anion and cation components modelled earlier are combined, and used to model simultaneously typical concentrations of ammonia, sodium, chloride and sulphate. Examples of operation are given, and observations and points of interest are discussed with respect to the calculated concentration profiles. The experimental behaviour of a number of resin samples taken from operating plant was examined in a purpose-built ultrapure water recirculation loop equipped with a range of analytical instruments. This has permitted the observed experimental results to be compared with model predictions. The next stage of the model development is to identify plants suitable for testing the model against real plant performance and the authors are now seeking to identify plant managers interested in collaborating in this venture. (orig.)

  11. MODELING OF OPERATION MODES OF SHIP POWER PLANT OF COMBINED PROPULSION COMPLEX WITH CONTROL SYSTEM BASED ON ELECTRONIC CONTROLLERS

    Directory of Open Access Journals (Sweden)

    E. A. Yushkov

    2016-12-01

    Full Text Available Purpose. Designing of diagrams to optimize mathematic model of the ship power plant (SPP combined propulsion complexes (CPC for decreasing operational loss and increasing fuel efficiency with simultaneous load limiting on medium revolutions diesel generator (MRDG by criterion reducing of wear and increasing operation time between repairs. Methodology. After analyzing of ship power plant modes of CPC proposed diagrams to optimize mathematic model of the above mentioned complex. The model based on using of electronic controllers in automatic regulation and control systems for diesel and thruster which allow to actualize more complicated control algorithm with viewpoint of increasing working efficiency of ship power plant at normal and emergency modes. Results. Determined suitability of comparative computer modeling in MatLab Simulink for building of imitation model objects based on it block diagrams and mathematic descriptions. Actualized diagrams to optimize mathematic model of the ship’s power plant (SPP combined propulsion complexes (CPC with Azipod system in MatLab Simulink software package Ships_CPC for decreasing operational loss and increasing fuel efficiency with simultaneous load limiting on medium revolutions diesel generator (MRDG by criterion reducing of wear and increasing operation time between repairs. The function blocks of proposed complex are the main structural units which allow to investigate it normal and emergency modes. Originality. This model represents a set of functional blocks of the components SPP CPC, built on the principle of «input-output». For example, the function boxes outputs of PID-regulators of MRDG depends from set excitation voltage and rotating frequency that in turn depends from power-station load and respond that is a ship moving or dynamically positioning, and come on input (inputs of thruster rotating frequency PID-regulator models. Practical value. The results of researches planned to use in

  12. User centered design of a digital procedure guidance component for nuclear power plant operation

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Paulo V.R. de; Santos, Isaac L. dos; Oliveira, Mauro V. de; Grecco, Claudio H.S.; Mol, Antonio C. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)]. E-mails: paulov@ien.gov.br; luquetti@ien.gov.br; mvitor@ien.gov.br; grecco@ien.gov.br; mol@ien.gov.br

    2007-07-01

    The use of nuclear power plants to produce electric energy is a safety-critical process where ultimate operational decisions still relies with the control room operators. Thus it is important to provide the best possible decision support through effective supervisory control interfaces. A user centered design approach, based on cognitive task analysis methods, was used to observe the operators training on the nuclear power plant simulator of the Human System Interface Laboratory (LABIHS). We noted deficiencies in the integration between the computerized interfaces and the hardcopy (paper) procedures. An new prototype of digital procedures - the digital procedure component guidance (PCG) - was designed in PowerPoint as an alternative to the current hardcopy procedure manuals. The design improves upon the graphical layout of system information and provides better integration of procedures, automation, and alarm systems. The design was validated by expert opinion and a scenario-based comparison. Future implementation and testing of the redesign is suggested for further validation. (author)

  13. Control and decision strategies in wastewater treatment plants for operation improvement

    CERN Document Server

    Santín, Ignacio; Vilanova, Ramón

    2017-01-01

    This book examines the operation of biological wastewater treatment plants (WWTPs), with a focus on maintaining effluent water quality while keeping operational costs within constrained limits. It includes control operation and decision schemes and is based on the use of benchmarking scenarios that yield easily reproducible results that readers can implement for their own solutions. The final criterion is the effect of the applied control strategy on plant performance – specifically, improving effluent quality, reducing costs and avoiding violations of established effluent limits. The evaluation of the different control strategies is achieved with the help of two Benchmark Simulation Models (BSM1, BSM2). Given the complexity of the biological and biochemical processes involved and the major fluctuations in the influent flow rate, controlling WWTPs poses a serious challenge. Further, the importance of control goal formulation and control structure design in relation to WWTP process control is widely recogniz...

  14. Methods for planning and operating decentralized combined heat and power plants

    Energy Technology Data Exchange (ETDEWEB)

    Palsson, H.

    2000-02-01

    In recent years, the number of decentralized combined heat and power (DCHP) plants, which are typically located in small communities, has grown rapidly. These relatively small plants are based on Danish energy resources, mainly natural gas, and constitute an increasing part of the total energy production in Denmark. The topic of this thesis is the analysis of DCHP plants, with the purpose to optimize the operation of such plants. This involves the modelling of district heating systems, which are frequently connected to DCHP plants, as well as the use of heat storage for balancing between heat and power production. Furthermore, the accumulated effect from increasing number of DCHP plants on the total power production is considered. Methods for calculating dynamic temperature response in district heating (DH) pipes have been reviewed and analyzed numerically. Furthermore, it has been shown that a tree-structured DH network consisting of about one thousand pipes can be reduced to a simple chain structure of ten equivalent pipes without loosing much accuracy when temperature dynamics are calculated. A computationally efficient optimization method based on stochastic dynamic programming has been designed to find an optimum start-stop strategy for a DCHP plant with a heat storage. The method focuses on how to utilize heat storage in connection with CHP production. A model for the total power production in Eastern Denmark has been applied to the accumulated DCHP production. Probability production simulations have been extended from the traditional power-only analysis to include one or several heat supply areas. (au)

  15. Water use in the development and operation of geothermal power plants.

    Energy Technology Data Exchange (ETDEWEB)

    Clark, C. E.; Harto, C. B.; Sullivan, J. L.; Wang, M. Q. (Energy Systems); ( EVS)

    2010-09-17

    Geothermal energy is increasingly recognized for its potential to reduce carbon emissions and U.S. dependence on foreign oil. Energy and environmental analyses are critical to developing a robust set of geothermal energy technologies. This report summarizes what is currently known about the life cycle water requirements of geothermal electric power-generating systems and the water quality of geothermal waters. It is part of a larger effort to compare the life cycle impacts of large-scale geothermal electricity generation with other power generation technologies. The results of the life cycle analysis are summarized in a companion report, Life Cycle Analysis Results of Geothermal Systems in Comparison to Other Power Systems. This report is divided into six chapters. Chapter 1 gives the background of the project and its purpose, which is to inform power plant design and operations. Chapter 2 summarizes the geothermal electricity generation technologies evaluated in this study, which include conventional hydrothermal flash and binary systems, as well as enhanced geothermal systems (EGS) that rely on engineering a productive reservoir where heat exists but water availability or permeability may be limited. Chapter 3 describes the methods and approach to this work and identifies the four power plant scenarios evaluated: a 20-MW EGS plant, a 50-MW EGS plant, a 10-MW binary plant, and a 50-MW flash plant. The two EGS scenarios include hydraulic stimulation activities within the construction stage of the life cycle and assume binary power generation during operations. The EGS and binary scenarios are assumed to be air-cooled power plants, whereas the flash plant is assumed to rely on evaporative cooling. The well field and power plant design for the scenario were based on simulations using DOE's Geothermal Economic Technology Evaluation Model (GETEM). Chapter 4 presents the water requirements for the power plant life cycle for the scenarios evaluated. Geology

  16. Water use in the development and operation of geothermal power plants.

    Energy Technology Data Exchange (ETDEWEB)

    Clark, C. E.; Harto, C. B.; Sullivan, J. L.; Wang, M. Q. (Energy Systems); ( EVS)

    2010-09-17

    Geothermal energy is increasingly recognized for its potential to reduce carbon emissions and U.S. dependence on foreign oil. Energy and environmental analyses are critical to developing a robust set of geothermal energy technologies. This report summarizes what is currently known about the life cycle water requirements of geothermal electric power-generating systems and the water quality of geothermal waters. It is part of a larger effort to compare the life cycle impacts of large-scale geothermal electricity generation with other power generation technologies. The results of the life cycle analysis are summarized in a companion report, Life Cycle Analysis Results of Geothermal Systems in Comparison to Other Power Systems. This report is divided into six chapters. Chapter 1 gives the background of the project and its purpose, which is to inform power plant design and operations. Chapter 2 summarizes the geothermal electricity generation technologies evaluated in this study, which include conventional hydrothermal flash and binary systems, as well as enhanced geothermal systems (EGS) that rely on engineering a productive reservoir where heat exists but water availability or permeability may be limited. Chapter 3 describes the methods and approach to this work and identifies the four power plant scenarios evaluated: a 20-MW EGS plant, a 50-MW EGS plant, a 10-MW binary plant, and a 50-MW flash plant. The two EGS scenarios include hydraulic stimulation activities within the construction stage of the life cycle and assume binary power generation during operations. The EGS and binary scenarios are assumed to be air-cooled power plants, whereas the flash plant is assumed to rely on evaporative cooling. The well field and power plant design for the scenario were based on simulations using DOE's Geothermal Economic Technology Evaluation Model (GETEM). Chapter 4 presents the water requirements for the power plant life cycle for the scenarios evaluated. Geology

  17. Lesson Learned from the Recent Operating Experience of Domestic Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang-Ju; Kim, Min-Chull; Koo, Bon-Hyun; Kim, Sang-Jae; Lee, Kyung-Won; Kim, Ji-Tae; Lee, Durk-Hun [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2007-10-15

    According to the public concerns, it seems that one of the main missions of a nuclear regulatory body is to collect operational experiences from various nuclear facilities, and to analyze their follow-up information. The extensive use of lessons learned from operating experiences to back fit safety systems, improve operator training and emergency procedures, and to focus more attention on human factors, safety culture and quality management systems are also desired. Collecting operational experiences has been mainly done regarding the incidents and major failures of components (so called 'event'), which usually demands lots of regulatory resources. This paper concentrates on new information, i.e. lesson learned from recent investigation results of domestic events which contain 5 years' experience. This information can induce many insights for improving operational safety of nuclear power plants (NPPs)

  18. Diagnostics of subtropical plants functional state by cluster analysis

    Directory of Open Access Journals (Sweden)

    Oksana Belous

    2016-05-01

    Full Text Available The article presents an application example of statistical methods for data analysis on diagnosis of the adaptive capacity of subtropical plants varieties. We depicted selection indicators and basic physiological parameters that were defined as diagnostic. We used evaluation on a set of parameters of water regime, there are: determination of water deficit of the leaves, determining the fractional composition of water and detection parameters of the concentration of cell sap (CCS (for tea culture flushes. These settings are characterized by high liability and high responsiveness to the effects of many abiotic factors that determined the particular care in the selection of plant material for analysis and consideration of the impact on sustainability. On the basis of the experimental data calculated the coefficients of pair correlation between climatic factors and used physiological indicators. The result was a selection of physiological and biochemical indicators proposed to assess the adaptability and included in the basis of methodical recommendations on diagnostics of the functional state of the studied cultures. Analysis of complex studies involving a large number of indicators is quite difficult, especially does not allow to quickly identify the similarity of new varieties for their adaptive responses to adverse factors, and, therefore, to set general requirements to conditions of cultivation. Use of cluster analysis suggests that in the analysis of only quantitative data; define a set of variables used to assess varieties (and the more sampling, the more accurate the clustering will happen, be sure to ascertain the measure of similarity (or difference between objects. It is shown that the identification of diagnostic features, which are subjected to statistical processing, impact the accuracy of the varieties classification. Selection in result of the mono-clusters analysis (variety tea Kolhida; hazelnut Lombardsky red; variety kiwi Monty

  19. Steady-state and non-steady state operation of counter-current chromatography devices.

    Science.gov (United States)

    Kostanyan, Artak E; Ignatova, Svetlana N; Sutherland, Ian A; Hewitson, Peter; Zakhodjaeva, Yulya A; Erastov, Andrey A

    2013-11-01

    Different variants of separation processes based on steady-state (continuous sample loading) and non-steady state (batch) operating modes of CCC columns have been analyzed and compared. The analysis is carried out on the basis of the modified equilibrium cell model, which takes into account both mechanisms of band broadening - interphase mass transfer and axial mixing. A full theoretical treatment of the intermittent counter-current chromatography with short sample loading time is performed. Analytical expressions are presented allowing the simulation of the intermittent counter-current chromatography separations for various experimental conditions. Chromatographic and extraction separations have been compared and advantages and disadvantages of the two methods have been evaluated. Further technical development of the CCC machines to implement counter-current extraction separations is considered.

  20. Operational air quality forecast guidance for the United States

    Science.gov (United States)

    Stajner, Ivanka; Lee, Pius; Tong, Daniel; Pan, Li; McQueen, Jeff; Huang, Jinaping; Djalalova, Irina; Wilczak, James; Huang, Ho-Chun; Wang, Jun; Stein, Ariel; Upadhayay, Sikchya

    2016-04-01

    NOAA provides operational air quality predictions for ozone and wildfire smoke over the United States (U.S.) and predictions of airborne dust over the contiguous 48 states at http://airquality.weather.gov. These predictions are produced using U.S. Environmental Protection Agency (EPA) Community Model for Air Quality (CMAQ) and NOAA's HYSPLIT model (Stein et al., 2015) with meteorological inputs from the North American Mesoscale Forecast System (NAM). The current efforts focus on improving test predictions of fine particulate matter (PM2.5) from CMAQ. Emission inputs for ozone and PM2.5 predictions include inventory information from the U.S. EPA and recently added contributions of particulate matter from intermittent wildfires and windblown dust that rely on near real-time information. Current testing includes refinement of the vertical grid structure in CMAQ and inclusion of contributions of dust transport from global sources into the U.S. domain using the NEMS Global Aerosol Capability (NGAC). The addition of wildfire smoke and dust contributions in CMAQ reduced model underestimation of PM2.5 in summertime. Wintertime overestimation of PM2.5 was reduced by suppressing emissions of soil particles when the terrain is covered by snow or ice. Nevertheless, seasonal biases and biases in the diurnal cycle of PM2.5 are still substantial. Therefore, a new bias correction procedure based on an analog ensemble approach was introduced (Djalalova et al., 2015). It virtually eliminates biases in monthly means or in the diurnal cycle, but it also reduces day-to-day variability in PM2.5 predictions. Refinements to the bias correction procedure are being developed. Upgrades for the representation of wildfire smoke emissions within the domain and from global sources are in testing. Another area of active development includes approaches to scale emission inventories for nitrogen oxides in order to reproduce recent changes observed by the AirNow surface monitoring network and by

  1. Inventory of power plants in the United States as of January 1, 1998

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    The Inventory of Power Plants in the United States provides annual statistics on generating units operated by electric utilities in the US (the 50 States and the District of Columbia). Statistics presented in this report reflect the status of generating units as of January 1, 1998. The publication also provides a 10-year outlook for generating unit additions and generating unit changes. This report is prepared annually by the Energy Information Administration (EIA). Data summarized in this report are useful to a wide audience. This is a report of electric utility data; in cases where summary data or nonconfidential data of nonutilities are presented, it is specifically noted as nonutility data. 19 figs., 36 tabs.

  2. Exotic Plant Invasion Risk in the Western United States

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This model was constructed to model the risk of invasion by exotic plant species. Roads may directly influence exotic plant dispersal via disturbance during road...

  3. Accidental introductions are an important source of invasive plants in the continental United States.

    Science.gov (United States)

    Lehan, Nora E; Murphy, Julia R; Thorburn, Lukas P; Bradley, Bethany A

    2013-07-01

    Preventing new plant invasions is critical for reducing large-scale ecological change. Most studies have focused on the deliberate introduction of nonnatives via the ornamental plant trade. However, accidental introduction may be an important source of nonnative, invasive plants. Using Web and literature searches, we compiled pathways of introduction to the United States for 1112 nonnative plants identified as invasive in the continental United States. We assessed how the proportion of accidentally and deliberately introduced invasive plants varies over time and space and by growth habit across the lower 48 states. Deliberate introductions of ornamentals are the primary source of invasive plants in the United States, but accidental introductions through seed contaminants are an important secondary source. Invasive forbs and grasses are the most likely to have arrived accidentally through seed contaminants, while almost all nonnative, invasive trees were introduced deliberately. Nonnative plants invading eastern states primarily arrived deliberately as ornamentals, while a high proportion of invasive plants in western states arrived accidentally as seed contaminants. Accidental introductions may be increasing in importance through time. Before 1850, 10 of 89 (11%) of invasive plants arrived accidentally. After 1900, 20 of 65 (31%) arrived accidentally. Recently enacted screening protocols and weed risk assessments aim to reduce the number of potentially invasive species arriving to the United States via deliberate introduction pathways. Increasing proportions of accidentally introduced invasive plants, particularly associated with contaminated seed imports across the western states, suggest that accidental introduction pathways also need to be considered in future regulatory decisions.

  4. Final Report on the Operation and Maintenance Improvement Program for Concentrating Solar Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Cohen Gilbert E.; Kearney, David W.; Kolb, Gregory J.

    1999-06-01

    This report describes the results of a six-year, $6.3 million project to reduce operation and maintenance (O&M) costs at power plants employing concentrating solar power (CSP) technology. Sandia National Laboratories teamed with KJC Operating Company to implement the O&M Improvement Program. O&M technologies developed during the course of the program were demonstrated at the 150-MW Kramer Junction solar power park located in Boron, California. Improvements were made in the following areas: (a) efficiency of solar energy collection, (b) O&M information management, (c) reliability of solar field flow loop hardware, (d) plant operating strategy, and (e) cost reduction associated with environmental issues. A 37% reduction in annual O&M costs was achieved. Based on the lessons learned, an optimum solar- field O&M plan for future CSP plants is presented. Parabolic trough solar technology is employed at Kramer Junction. However, many of the O&M improvements described in the report are also applicable to CSP plants based on solar power tower or dish/engine concepts.

  5. Online Condition Monitoring to Enable Extended Operation of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Ryan M.; Bond, Leonard J.; Ramuhalli, Pradeep

    2012-03-31

    Safe, secure, and economic operation of nuclear power plants will remain of strategic significance. New and improved monitoring will likely have increased significance in the post-Fukushima world. Prior to Fukushima, many activities were already underway globally to facilitate operation of nuclear power plants beyond their initial licensing periods. Decisions to shut down a nuclear power plant are mostly driven by economic considerations. Online condition monitoring is a means to improve both the safety and economics of extending the operating lifetimes of nuclear power plants, enabling adoption of proactive aging management. With regard to active components (e.g., pumps, valves, motors, etc.), significant experience in other industries has been leveraged to build the science base to support adoption for online condition-based maintenance and proactive aging management in the nuclear industry. Many of the research needs are associated with enabling proactive management of aging in passive components (e.g., pipes, vessels, cables, containment structures, etc.). This paper provides an overview of online condition monitoring for the nuclear power industry with an emphasis on passive components. Following the overview, several technology/knowledge gaps are identified, which require addressing to facilitate widespread online condition monitoring of passive components.

  6. Control of radio-iodine at the German reprocessing plant WAK during operation and after shutdown

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, F.J.; Herrmann, B.; Kuhn, K.D. [Wiederaufarbeitungsanlage Karlsruhe (Germany)] [and others

    1997-08-01

    During 20 years of operation 207 metric tons of oxide fuel from nuclear power reactors with 19 kg of iodine-129 had been reprocessed in the WAK plant near Karlsruhe. In January 1991 the WAK Plant was shut down. During operation iodine releases of the plant as well as the iodine distribution over the liquid and gaseous process streams had been determined. Most of the iodine is evolved into the dissolver off-gas in volatile form. The remainder is dispersed over many aqueous, organic and especially gaseous process and waste streams. After shut down of the plant in January 1991, iodine measurements in the off-gas streams have been continued up to now. Whereas the iodine-129 concentration in the dissolver off-gas dropped during six months after shutdown by three orders of magnitude, the iodine concentrations in the vessel ventilation system of the PUREX process and the cell vent system decreased only by a factor of 10 during the same period. Iodine-129 releases of the liquid high active waste storage tanks did not decrease distinctly. The removal efficiencies of the silver impregnated iodine filters in the different off-gas streams of the WAK plant depend on the iodine concentration in the off-gas. The reason of the observed dependence of the DF on the iodine-129 concentration might be due to the presence of organic iodine compounds which are difficult to remove. 13 refs., 3 figs.

  7. Paradise lost: alien plant invaders compromising productive, rich state forests

    Science.gov (United States)

    Nancy J. Loewenstein; James H. Miller; Erwin Chamblis

    2008-01-01

    Kudzu and Chinese privet along Alabama roadways are a familiar sight and Japanese honeysuckle is so commonplace it has practically become a part of Southern culture. But are these and other invasive plants really having a negative impact on forests? Just how bad is the invasive plant problem? What are the most effective ways to combat invasive plants?

  8. United States Military in Central Asia: Beyond Operation Enduring Freedom

    Science.gov (United States)

    2009-10-23

    Malinowski , advocacy director for Human Rights Watch, stated, “the United States is most effective in promoting liberty around the world when people...26 U.S. President, The National Security Strategy of the United States of America, page? 27 Thomas Malinowski , “Testimony

  9. 12 CFR 9.7 - Multi-state fiduciary operations.

    Science.gov (United States)

    2010-01-01

    ... act as fiduciary for, customers located in any state, and it may act as fiduciary for relationships....C. 92a. For each fiduciary relationship, the state referred to in section 92a is the state in which the bank acts in a fiduciary capacity for that relationship. A national bank acts in a fiduciary...

  10. State complexity of catenation combined with boolean operations

    OpenAIRE

    Caron, Pascal; Luque, Jean-Gabriel; Patrou, Bruno

    2017-01-01

    We exhaustively investigate possible combinations of a boolean operation together with a catenation. In many cases we prove and improve some conjectures by Brzozowski. For each family of operation, we endeavour to provide a common witness with a small size alphabet.

  11. Atomic Coherent State, Entangled State and Phase Operator for Studying Interference Between Two Bose-Einstein Condensates

    Institute of Scientific and Technical Information of China (English)

    TANG Xu-Bing; FAN Hong-Yi

    2008-01-01

    For studying the interference between two Bose-Einstein condensates we introduce the atomic coherent state (ACS) in the Schwinger bosonic realization along with the phase operator to directly calculate the interference pattern with steady relative phase cos φ. Eigenstates of the density operator of condensates are classified as ACS is also demonstrated. The entangled state representation is used in some calculations.

  12. Macroscopic mass and energy balance of a pilot plant anaerobic bioreactor operated under thermophilic conditions.

    Science.gov (United States)

    Espinosa-Solares, Teodoro; Bombardiere, John; Chatfield, Mark; Domaschko, Max; Easter, Michael; Stafford, David A; Castillo-Angeles, Saul; Castellanos-Hernandez, Nehemias

    2006-01-01

    Intensive poultry production generates over 100,000 t of litter annually in West Virginia and 9 x 10(6) t nationwide. Current available technological alternatives based on thermophilic anaerobic digestion for residuals treatment are diverse. A modification of the typical continuous stirred tank reactor is a promising process being relatively stable and owing to its capability to manage considerable amounts of residuals at low operational cost. A 40-m3 pilot plant digester was used for performance evaluation considering energy input and methane production. Results suggest some changes to the pilot plant configuration are necessary to reduce power consumption although maximizing biodigester performance.

  13. Operation of Finnish nuclear power plants. Quarterly report, 2nd quarter 1999

    Energy Technology Data Exchange (ETDEWEB)

    Tossavainen, K. [ed.

    1999-12-01

    Quarterly reports on the operation of Finnish NPPs describe events and observations relating to nuclear and radiation safety that the Finnish Radiation and Nuclear Safety Authority (STUK) considers safety significant. Safety improvements at the plants are also described. The report includes a summary of the radiation safety of plant personnel and the environment and tabulated data on the plants' production and load factors. All Finnish NPP units were in power operation for the whole second quarter of 1999, with the exception of the annual maintenance outages of the Olkiluoto plant units. The load factor average of the plant units in this quarter was 93.1%. Two events in this quarter were classified Level 1 on the INKS Scale. At Olkiluoto 1, a valve of the containment gas treatment system had been in an incorrect position for almost a month, owing to which the system would not have been available as planned in an accident. At Olkiluoto 2, main circulation pump work was done during the annual maintenance outage and a containment personnel air lock was briefly open in violation of the Technical Specifications. Water leaking out of the reactor in an accident could not have been directed to the emergency cooling system because it would have leaked out from the containment via the open personnel air lock. Other events in this quarter had no bearing on the nuclear or radiation safety of the plant units. The individual doses of NPP personnel and also radioactive releases off-site were well below authorised limits. Radioactive substances were measurable in samples collected around the plants in such quantities only as have no bearing on the radiation exposure of the population. (orig.)

  14. Operation and performance of the ICARUS-T600 cryogenic plant at Gran Sasso underground Laboratory

    CERN Document Server

    Antonello, M; Baibussinov, B; Boffelli, F; Bubak, A; Calligarich, E; Canci, N; Centro, S; Cesana, A; Cieślik, K; Cline, D B; Cocco, A G; Dabrowska, A; Dermenev, A; Disdier, J M; Falcone, A; Farnese, C; Fava, A; Ferrari, A; Gibin, D; Gninenko, S; Guglielmi, A; Haranczyk, M; Holeczek, J; Ivashkin, A; Kirsanov, M; Kisiel, J; Kochanek, I; Lagoda, J; Mania, S; Menegolli, A; Meng, G; Montanari, C; Otwinowski, S; Picchi, P; Pietropaolo, F; Plonski, P; Rappoldi, A; Raselli, G L; Rossella, M; Rubbia, C; Sala, P R; Scaramelli, A; Segreto, E; Sergiampietri, F; Stefan, D; Sulej, R; Szarska, M; Terrani, M; Torti, M; Varanini, F; Ventura, S; Vignoli, C; Wang, H G; Yang, X; Zalewska, A; Zani, A; Zaremba, K

    2015-01-01

    ICARUS T600 liquid argon time projection chamber is the first large mass electronic detector of a new generation able to combine the imaging capabilities of the old bubble chambers with the excellent calorimetric energy measurement. After the three months demonstration run on surface in Pavia during 2001, the T600 cryogenic plant was significantly revised, in terms of reliability and safety, in view of its long-term operation in an underground environment. The T600 detector was activated in Hall B of the INFN Gran Sasso Laboratory during Spring 2010, where it was operated without interruption for about three years, taking data exposed to the CERN to Gran Sasso long baseline neutrino beam and cosmic rays. In this paper the T600 cryogenic plant is described in detail together with the commissioning procedures that lead to the successful operation of the detector shortly after the end of the filling with liquid Argon. Overall plant performance and stability during the long-term underground operation are discusse...

  15. Thermoelectric power plant water withdrawals and associated attributes for three Federal datasets in the United States, 2010

    Science.gov (United States)

    Harris, Melissa A.; Diehl, Timothy H.

    2017-01-01

    This dataset combines three Federal datasets of thermoelectric, non-industrial, power plant water withdrawals and associated plant information for the United States in 2010, excluding Puerto Rico and the U.S. Virgin Islands. Historically, thermoelectric water withdrawal has been estimated by the Department of Energy's Energy Information Administration (EIA) through surveys of plant operator-reported data, and the Department of Interior's U.S. Geological Survey's (USGS) 5-year water-use reports including data compiled from state water agencies, plant operators, and the EIA. Recently, the USGS developed models for estimating withdrawal at thermoelectric plants to provide independent estimates from plant operator-reported data. The three Federal datasets include plant-level data for 1,349 plants derived from EIA's 2010 Form EIA-860 and Form EIA-923 databases, USGS 2010 compilation-reported data (hereafter referred to as the USGS-compilation dataset), and USGS 2010 model-estimated data (hereafter referred to as the USGS-model dataset). The plant-level USGS-compilation data provided in this dataset were disaggregated from county-level data published in USGS Circular 1405 (Maupin and others, 2014). The USGS-model data and the EIA data presented in this dataset were previously published in USGS Scientific Investigations Report 2014-5184 (Diehl and Harris, 2014). The year 2010 was chosen because it is the most recent year the USGS 5-year compilation report was published and the only year for which the USGS model estimates have been calculated.Diehl, T.H., and Harris, M.A., 2014, Withdrawal and consumption of water by thermoelectric power plants in the United States, 2010: U.S. Geological Survey Scientific Investigations Report 2014–5184, 28 p., http://dx.doi.org/10.3133/sir20145184.Maupin, M.A., Kenny, J.F., Hutson, S.S., Lovelace, J.K., Barber, N.L., and Linsey, K.S., 2014, Estimated use of water in the United States in 2010: U.S. Geological Survey Circular 1405, 56 p

  16. Thermal-hydraulic modeling of the steady-state operating conditions of a fire-tube boiler

    Directory of Open Access Journals (Sweden)

    Rahmani Ahmed

    2009-01-01

    Full Text Available In this work, we are interested to simulate the thermal-hydraulic behavior of three-pass type fire-tube boiler. The plant is designed to produce 4.5 tons per hour of saturated steam at 8 bar destined principally for heating applications. A calculation program is developed in order to simulate the boiler operation under several steady-state operating conditions. This program is based upon heat transfer laws between hot gases and the fire-tube internal walls. In the boiler combustion chamber, the heat transfer has been simulated using the well-stirred furnace model. In the convection section, heat balance has been carried out to estimate the heat exchanges between the hot gases and the tube banks. The obtained results are compared to the steady-state operating data of the considered plant. A comparative analysis shows that the calculation results are in good agreement with the boiler operating data. Furthermore, a sensitivity study has been carried out to assess the effects of input parameters, namely the fuel flow rate, air excess, ambient temperature, and operating pressure, upon the boiler thermal performances.

  17. State operator, constants of the motion, and Wigner functions: The two-dimensional isotropic harmonic oscillator

    DEFF Research Database (Denmark)

    Dahl, Jens Peder; Schleich, W. P.

    2009-01-01

    For a closed quantum system the state operator must be a function of the Hamiltonian. When the state is degenerate, additional constants of the motion enter the play. But although it is the Weyl transform of the state operator, the Wigner function is not necessarily a function of the Weyl...

  18. Towards Increasing State Support Efficiency of Mechanical Engineering Plants

    Directory of Open Access Journals (Sweden)

    L. I. Kushnarev

    2016-01-01

    Full Text Available The article discusses a hot topic concerning the organization and implementation of a proprietary method of the technical service aimed at solving the problems of technological modernization of manufacturing facilities, machines and equipment and more efficient use of financial means allocated by the government of the Russian Federation for these purposes through increasing a level of competitiveness thanks to growing quality and reliability of equipment. Based on the analysis the paper gives an accent on the factors that are capable to provide a rate of return sufficient for additional, along with the state support, investments of innovative development of the enterprise because of technological modernization of production. Such an approach to technological modernization of mechanical engineering plants allows 3–5 times enhancement of their development rates provided that a careful scheduling of activities is based on the organizational and technological design. The researches have allowed us to formulate the proposals for the project implementation on innovative development of mechanical engineering.

  19. Results of Continuous Load Cell Monitoring Field Trial for UF6 Withdrawals at an Operating Industrial Plant

    Energy Technology Data Exchange (ETDEWEB)

    Krichinsky, Alan M [ORNL; Bell, Lisa S [ORNL; Conchewski, Curtis A [ORNL; Peters, Benjamin R [ORNL; Pickett, Chris A [ORNL; Richardson, Dave [ORNL; Rowe, Nathan C [ORNL; Younkin, James R [ORNL

    2010-01-01

    Continuous load cell monitoring (CLCM) has been implemented and tested for use as a safeguards tool during a 2009 field trial in an operating UF6 transfer facility. The transfer facility is part of the Portsmouth Gaseous Diffusion Plant in Piketon, Ohio, operated by the United States Enrichment Corporation. During the field trial, two process scales for UF{sub 6} cylinders were continuously monitored for a 6-month period as cylinders were being filled. The collected CLCM data were used in testing an event processor serving as a filter for highlighting measurements representing significant operational activities that are important in verifying declared operations. The collection of CLCM data, coupled with rules-based event processing, can provide inspectors with knowledge of a facility's feed and withdrawal activities occurring between site visits. Such process knowledge promises to enhance the effectiveness of safeguards by enabling inspectors to quantitatively compare declared activities directly with process measurements. Selected results of the field trial and event processing will be presented in the context of their value to an independent inspector and a facility operator.

  20. Improvement of environmental aspects of thermal power plant operation by advanced control concepts

    Directory of Open Access Journals (Sweden)

    Mikulandrić Robert

    2012-01-01

    Full Text Available The necessity of the reduction of greenhouse gas emissions, as formulated in the Kyoto Protocol, imposes the need for improving environmental aspects of existing thermal power plants operation. Improvements can be reached either by efficiency increment or by implementation of emission reduction measures. Investments in refurbishment of existing plant components or in plant upgrading by flue gas desulphurization, by primary and secondary measures of nitrogen oxides reduction, or by biomass co-firing, are usually accompanied by modernisation of thermal power plant instrumentation and control system including sensors, equipment diagnostics and advanced controls. Impact of advanced control solutions implementation depends on technical characteristics and status of existing instrumentation and control systems as well as on design characteristics and actual conditions of installed plant components. Evaluation of adequacy of implementation of advanced control concepts is especially important in Western Balkan region where thermal power plants portfolio is rather diversified in terms of size, type and commissioning year and where generally poor maintenance and lack of investments in power generation sector resulted in high greenhouse gases emissions and low efficiency of plants in operation. This paper is intended to present possibilities of implementation of advanced control concepts, and particularly those based on artificial intelligence, in selected thermal power plants in order to increase plant efficiency and to lower pollutants emissions and to comply with environmental quality standards prescribed in large combustion plant directive. [Acknowledgements. This paper has been created within WBalkICT - Supporting Common RTD actions in WBCs for developing Low Cost and Low Risk ICT based solutions for TPPs Energy Efficiency increasing, SEE-ERA.NET plus project in cooperation among partners from IPA SA - Romania, University of Zagreb - Croatia and Vinca

  1. New risk indicator approach for Operators, Workers, Bystanders and Residents for a sustainable use of plant protection products.

    Science.gov (United States)

    Sacchettini, Gabriele; Calliera, Maura; Marchis, Alexandru; Glass, Richard; Ellis, Clare Butler; Machera, Kyriaki; Gerritsen-Ebben, Rianda; Spanoghe, Pieter; Capri, Ettore

    2015-11-01

    In 2009, the European Union adopted the Directive on Sustainable Use of pesticides (SUD, Directive 2009/128/EC) establishing a framework for achieving a sustainable use of Plant Protection Products (PPPs) through reducing the risks and impacts of PPP use on human health and the environment, promoting integrated pest management and stimulating effective non-chemical alternatives. The core idea of the SUD is that it is necessary to monitor the use of PPPs through the implementation of an appropriate set of risk indicators to monitor progress and trends in risk reduction within the Member States. To contribute to this direction, following a comprehensive analysis of the risk (including procedures of risk assessment and risk management) and involving stakeholders in the decision process, specific toolboxes of practical indirect risk indicators of exposure of Operators, Workers, Bystanders and Residents were developed and are now available to be used by Member States (MSs) based on their specific context.

  2. Resolving plant operational issues related to pressurizer safety relief valve piping

    Energy Technology Data Exchange (ETDEWEB)

    Bain, R.A. [Stone and Webster Engineering Corp., Boston, MA (United States). Mechanical Engineering Div.; Testa, M.F. [Duquesne Light Co., Shippingport, PA (United States). Mechanical Engineering Dept.

    1995-11-01

    Pressurizer safety and relief valve (PSARV) piping has many technical issues related to the qualification and operation of the system that have been addressed at Beaver Valley Unit 2. The PSARV piping is part of a system that must meet Code requirements while being subjected to very significant fluid transient loadings. Valve components include safety valves, power operated relief valves (PORVs), and motor operated block valves. Fluid slugs upstream of these valves can be steam or can be hot or cold water, resulting in a significant variance in possible slug densities. Problems with design options and hardware installed to decrease slug density such as heat tracing, and the susceptibility of the PORVs to leak are issues that affect plant operation, efficiency and cost effectiveness.

  3. Operational Efficiency of Public Transport System in Kwara State ...

    African Journals Online (AJOL)

    Open Access DOWNLOAD FULL TEXT ... While the public Corporations are established by governments, private service operations are ... Data were also collected from records of the Transport Corporation relating to passenger traffic, bus ...

  4. Interaction Operators with State through Public Consolidated Budget

    Directory of Open Access Journals (Sweden)

    Luhan Ionuţ Dragos

    2009-06-01

    Full Text Available Operation of a proper market economy is influenced in an important measure ofthe interaction with operators, respectively, how to run the financial relations between thepublic and strengthened economic resources for the purposes of training and public budgetaryallocation of resources in economic benefit. In the above still trying to achieve severalimportant issues relating to financial relations between the private and the public enhanced.

  5. Optimal operation of cascaded hydroelectric power plants in the power market

    Institute of Scientific and Technical Information of China (English)

    蔡兴国; 马平; 林士颖

    2004-01-01

    An improved network flow algorithm, which includes the minimum cost network flow and the same period network flow, is proposed to solve the optimization of cascaded hydroelectric power plants in a competitive electricity market. The typical network flow is used to find the feasible flow and add the discharge water to different cascaded hydroelectric power plants at the same step. The same period network flow is used to find the optimal flow and add the power output at a different step. This new algorithm retains the advantages of the typical network flow, such as simplicity and ease of realization. The result of the case analysis indicates that the new algorithm can achieve high calculation precision and can be used to calculate the optimal operation of cascaded hydroelectric power plants.

  6. Integration of computerized operation support systems on a nuclear power plant environment

    Energy Technology Data Exchange (ETDEWEB)

    Jaime, Guilherme D.G.; Almeida, Jose C.S.; Oliveira, Mauro V., E-mail: gdjaime@ien.gov.br, E-mail: jcsa@ien.gov.br, E-mail: mvitor@ien.gov.br [Instituto Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Servico de Sistemas Complexos. Divisao de Engenharia Nuclear

    2015-07-01

    Automation of certain tasks in a Nuclear Power Plant (NPP) control room is expected to result in reduced operators' mental workload, which may induce other benefits such as enhanced situation awareness and improved system performance. The final goal should be higher level of operational safety. Thus, recent works are increasingly assessing automation. The LABIHS compact NPP simulator, though, still operates under strictly manual printed hard-copy procedures, despite of the fact that the simulator incorporates several advancements in design of digitalized Human-Interfaces (HSIs). This work presents the development, implementation and integration of selected components to achieve increased level of computerized/automated operation of the LABIHS compact NPP simulator. Specifically, we discuss three components: (I) Automatic Plant Mode Detection, (II) Automatic Alarm Filtering, and (III) Computerized Procedures. Each one of these components has to be carefully designed/integrated so that one can avoid the undesired effects of some known implementations of automated systems on NPP, such as the reduction in the operator's system awareness, an increase in monitoring workload, and the degradation in manual skills, which could lead to automation-induced system failures. (author)

  7. Controlling the Filling and Capping Operation of a Bottling Plant using PLC and SCADA

    Directory of Open Access Journals (Sweden)

    Kunal Chakraborty

    2015-03-01

    Full Text Available This paper presents basic stages of operation of a bottling plant, i.e. the filling and capping process. The main aim of our paper is to control the filling and capping section of a bottling plant simultaneously. At first a set of empty bottle is run by using a conveyer towards filling section, after the operation, the filled bottles are sent towards the capping section. After successful capping operation, the sealed bottles terminate towards exit and a new set of empty bottle arrive, in this way the process continues. This paper includes the method using which, a bunch of bottles can be filled and capped at one instant of time. This method has made the operation more flexible and time saving. The filling and capping operations are controlled using Programmable Logic Controllers (PLC, as the PLC’s are very much user-efficient, cost-effective and easy to control. By using PLC automation the whole process is kept under control. SCADA (Supervisory Control and Data Acquisition is used to monitor the process by means of a display system.

  8. A study of air-operated valves in U.S. nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Rothberg, O. [Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID (United States); Khericha, S. [Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID (United States); Watkins, J. [Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID (United States); Holbrook, M. [Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID (United States)

    2000-02-01

    A study of air-operated valves in nuclear power plant applications was conducted for the NRC Office of Research (the project was initiated by NRC/AEOD). The results of the study were based on visits to seven nuclear power plant sites, literature studies, and examinations of event records in databases available to the NRC. The purpose is to provide information to the NRC staff concerning capabilities and performance of air-operated valves (AOVs). Descriptions of air systems and AOVs were studied along with the support systems and equipment. Systems and equipment that contain AOVs and SOVs were studied to determine their dependencies. Applications of AOVs and SOVs were listed along with current NRC requirements.

  9. Operational and field test results from the 500 kw direct contact pilot plant at East Mesa

    Energy Technology Data Exchange (ETDEWEB)

    Hlinak, A.J.; Lobach, J.L.; Nichols, K.E.

    1981-10-01

    A 500 kw geothermal powerplant utilizing direct contact heat exchange (DCHX) between geothermal brine and an isobutane (IC/sub 4/) working fluid is currently operating at the East Mesa test facility. The pilot plant program was initiated to determine the feasibility of large-scale direct contact heat exchange and associated plant operations. In addition to verifying the design performance of the DCHX itself, test efforts to date have (1) quantified the effect of dissolved gases (primarily CO/sub 2/) transferred from the brine to the IC/sub 4/ loop on the pressure elevation in the unvented power condenser and demonstrated a viable scheme to control this pressure elevation, (2) evaluated the potential of flash extraction and recovery of dissolved IC/sub 4/ from the spent brine, and (3) demonstrated control of fouling in critical components by pretreating the brine with small amounts of a chemical additive (FLOCON 247, Pfizer, Inc.).

  10. Analysis of the Impact of Decreasing District Heating Supply Temperature on Combined Heat and Power Plant Operation

    OpenAIRE

    Bolonina Alona; Bolonins Genadijs; Blumberga Dagnija

    2014-01-01

    District heating systems are widely used to supply heat to different groups of heat consumers. The district heating system offers great opportunities for combined heat and power production. In this paper decreasing district heating supply temperature is analysed in the context of combined heat and power plant operation. A mathematical model of a CHP plant is developed using both empirical and theoretical equations. The model is used for analysis of modified CHP plant operation modes with redu...

  11. Air quality assessment of benzo(a)pyrene from asphalt plant operation.

    Science.gov (United States)

    Gibson, Nigel; Stewart, Robert; Rankin, Erika

    2012-01-01

    A study has been carried out to assess the contribution of Polycyclic Aromatic Hydrocarbons (PAHs) from asphalt plant operation, utilising Benzo(a)pyrene (BaP) as a marker for PAHs, to the background air concentration around asphalt plants in the UK. The purpose behind this assessment was to determine whether the use of published BaP emission factors based on the US Environmental Protection Agency (EPA) methodology is appropriate in the context of the UK, especially as the EPA methodology does not give BaP emission factors for all activities. The study also aimed to improve the overall understanding of BaP emissions from asphalt plants in the UK, and determine whether site location and operation is likely to influence the contribution of PAHs to ambient air quality. In order to establish whether the use of US EPA emissions factors is appropriate, the study has compared the BaP emissions measured and calculated emissions rates from two UK sites with those estimated using US EPA emission factors. A dispersion modelling exercise was carried out to show the BaP contribution to ambient air around each site. This study showed that, as the US EPA methodology does not provide factors for all emission sources on asphalt plants, their use may give rise to over- or under-estimations, particularly where sources of BaP are temperature dependent. However, the contribution of both the estimated and measured BaP concentrations to environmental concentration were low, averaging about 0.05 ng m(-3) at the boundary of the sites, which is well below the UK BaP assessment threshold of 0.25 ng m(-3). Therefore, BaP concentrations, and hence PAH concentrations, from similar asphalt plant operations are unlikely to contribute negatively to ambient air quality.

  12. Four modes of optical parametric operation for squeezed state generation

    DEFF Research Database (Denmark)

    Andersen, Ulrik Lund; Buchler, B.C.; Lam, P.K.;

    2003-01-01

    of this light, including a full quantum state tomography. In addition we demonstrate the direct detection of the squeezed state statistics without the aid of a spectrum analyser. This technique makes the nonclassical properties directly visible and allows complete measurement of the statistical moments...

  13. Towards maintenance-free SOVs (solenoid operated valves). [For nuclear power plant use

    Energy Technology Data Exchange (ETDEWEB)

    Rustagi, R. (Valcor Engineering Corp., Springfield, NJ (USA))

    1991-05-01

    Because most solenoid operated valves (SOVs) are being used in vital safety related systems in nuclear power plants, they must be shown to perform satisfactorily over 40 years of normal service plus one year into post-LOCA. Current practice in SOV design and manufacture, as described here, aims to minimize the need for maintenance and to make it simpler when it is necessary. (author).

  14. Evaluation of performance of a BLSS model in long-term operation in dynamic and steady states

    Science.gov (United States)

    Gros, Jean-Bernard; Tikhomirov, Alex; Ushakova, Sofya; Velitchko, Vladimir; Tikhomirova, Natalia; Lasseur, Christophe

    Evaluation of performance of a BLSS model, including higher plants for food production and biodegradation of human waste, in long-term operation in dynamic and steady states was performed. The model system was conceived for supplying vegetarian food and oxygen to 0.07 human. The following data were obtained in steady-state operating conditions. Average rate of wheat, chufa, radish, lettuce and Salicornia edible biomass accumulation were 8.7, 5.5, 0.6, 0.6 and metricconverterProductID2.5 g2.5 g per day respectively. Thus, to mimic the vegetarian edible biomass consumption by a human it was necessary to withdraw 17.9 g/d from total mass ex-change. Simultaneously, human mineralized exometabolites (artificial mineralized urine, AMU) in the amount of approximately 7% of a daily norm were introduced into the nutrient solu-tion for irrigation of the plants cultivated on a neutral substrate (expanded clay aggregate). The estimated value of 5.8 g/d of wheat and Salicornia inedible biomass was introduced in the soil-like substrate (SLS) to fully meet the plants need in nitrogen. The rest of wheat and Salicornia inedible biomass, 5.7 g/d, was stored. Thus in all, 23.6g of vegetarian dry matter had been stored. Assuming edible biomass is eaten up by the human, the closure coefficient of the vegetarian biomass inclusion into matter recycling amounted to 88%. The analysis of the long-term model operation showed that the main factors limiting increase of recycling processes were the following: a) Partly unbalanced mineral composition of daily human waste with daily needs of plants culti-` vated in the system. Thus, when fully satisfied with respect to nitrogen, the plants experienced a lack of macro elements such as P, Mg and Ca by more than 50%; b) Partly unbalanced mineral composition of edible biomass of the plants cultivated in the SLS with that of inedible biomass of the plants cultivated by hydroponic method on neutral substrate introduced in the SLS; c) Accumulation of

  15. [Development characteristics of aquatic plants in a constructed wetland for treating urban drinking water source at its initial operation stage].

    Science.gov (United States)

    Zheng, Jun; Ma, Xin-Tang; Zhou, Lan; Zhou, Qing-Yuan; Wang, Zhong-Qiong; Wang, Wei-Dong; Yin, Cheng-Qing

    2011-08-01

    The development characteristics and improvement measures of aquatic plants were studied in Shijiuyang Constructed Wetland (SCW) at its initial operation stage. SCW was a large-scale wetland aiming to help relieve the source water pollution in Jiaxing City. A checklist of vascular plants in SCW was built, and species composition, life forms, biomass and association distributions were examined. Our objectives were to examine the diversity and community structure of aquatic plants in SCW at its initial operation stage, and to find out the possible hydrophyte improvement measures. The survey results showed that there were 49 vascular plant species belonging to 41 genera, 25 families in SCW, which greatly exceeded the artificially transplanted 13 species. The life forms of present aquatic plants in SCW were dominated by hygrophilous plants (20 species) and emerged plants (17 species), which accounted for 75.5% of the total number of aquatic plants. The aquatic plants transplanted artificially were dominated by emerged plants (accounted for 69.2%), while those naturally developed were predominated by hygrophilous plants (accounted for 47.2%). The horizontal distribution of aquatic plant community in SCW was mixed in the form of mosaics, which made up typical association complex. Except association Aeschynomene indica L., the dominant species of other associations were all those transplanted artificially. The naturally grown species scattered throughout the SCW and only occupied a small percentage. A marked difference was detected on the species and species richness of aquatic plants in different regions of SCW. Biomass of aquatic plant associations in SCW was 167.7 t. SCW has shown a trend of succession heading for quick increase of plant diversity at the primary operation stage. This trend provides a good material base for the future stable community of aquatic plants in SCW. According to the current status of aquatic plants, some suggestions were put forward on the

  16. The Fermionic Signature Operator and Quantum States in Rindler Space-Time

    CERN Document Server

    Finster, Felix; Röken, Christian

    2016-01-01

    The fermionic signature operator is constructed in Rindler space-time. It is shown to be an unbounded self-adjoint operator on the Hilbert space of solutions of the massive Dirac equation. In two-dimensional Rindler space-time, we prove that the resulting fermionic projector state coincides with the Fulling-Rindler vacuum. Moreover, the fermionic signature operator gives a covariant construction of general thermal states, in particular of the Unruh state. The fermionic signature operator is shown to be well-defined in asymptotically Rindler space-times. In four-dimensional Rindler space-time, our construction gives rise to new quantum states.

  17. Towards a "crippled-mode" operation of an industrial wastewater treatment plant.

    Science.gov (United States)

    Szafnicki, Konrad; Narce, Cécile

    2006-02-01

    In house treatment of metal plating wastewater mainly involves chemical treatments performed in continuous flow stirred tank reactors (CFSTR). The inflow of these tanks is directly produced by the plating shops activity, and the storage capacity never exceeds a few hours of incoming flow. Thus, any fault on one of the CFSTR may impose a complete stop of the whole manufacturing process, which is unacceptable for the manufacturer. Another solution would be having "spare" CFSTRs ready to be used as alternative in case of any CFSTR fault or maintenance. The latter solution however implies additional costs in equipment, storage space and maintenance so as to keep this equipment fit and ready for operation. The paper presents the study of a "crippled-mode" wastewater treatment (WWT) operation which enables a sufficiently efficient working of the WWT plant during maintenance phases and failure repairing on any of the CFSTR, without any extra equipment needed. This survey has been performed on real industrial WWT plants, with a continuous influent and under industrial operation constraints. The performances of the detoxication have been analysed when a CFSTR is short-circuited and the corresponding chemical treatment is shunt in the upstream or downstream CSFTR. This work shows the possibility of satisfying the environmental regulations with a WWT plant functioning under subnormal conditions.

  18. Influencing Tomorrow: A Study of Emerging Influence Techniques and Their Relevance to United States Information Operations

    Science.gov (United States)

    2015-06-12

    groups and governmental institutions; the possibility of economic loss directed at entrepreneurs; or the prospect of United States undue influence or... INFLUENCING TOMORROW: A STUDY OF EMERGING INFLUENCE TECHNIQUES AND THEIR RELEVANCE TO UNITED STATES INFORMATION OPERATIONS A...

  19. Psychological factors of professional success of nuclear power plant main control room operators

    Directory of Open Access Journals (Sweden)

    Kosenkov A.A.

    2014-12-01

    Full Text Available Aim: to conduct a comparative analysis of the psychological characteristics of the most and least successful main control room operators. Material and Methods. Two NPP staff groups: the most and least successful main control room operators, who worked in routine operating conditions, were surveyed. Expert evaluation method has been applied to identify the groups. The subjects were administered the Minnesota Multiphasic Personality Inventory (MMPI, Cattell's Sixteen Personality Factor Questionnaire (16PF form A and Raven's Progressive Matrices test. Results. Numerous significant psychological differences between the groups of most and least successful control room operators were obtained: the best operators were significantly more introverted and correctly solved more logical tasks with smaller percentage of mistakes under time pressure than worst ones. Conclusions: 1. The psychodiagnostic methods used in the study were adequate to meet research objective 2. Tendency to introversion, as well as developed the ability to solve logic problems undertime pressure, apparently, are important professional qualities for control room operators. These indicators should be considered in the process of psychological selection and professional guidance of nuclear power plant operators.

  20. Can operations put the MPS into an unsafe state?

    CERN Document Server

    Ponce, L

    2011-01-01

    During the 2010 run, the MPS have been additionally stressed by the commissioning of operational procedures and systems tests. As requested by the MPS external review committee, human factors have to be further minimized and discipline reinforced when increasing the stored beam energies towards and beyond the 2010 target of 30 MJ. This talk will present a synthesis of the Evian discussion on MPS and human factors, with an emphasis on the tools and procedures to be put in place for the 2011 run in order to ensure the machine safety during standard beam operation and after periods of machine developments or technical stops.

  1. Member State Foreign Policy towards EU Military Operations

    DEFF Research Database (Denmark)

    Rodt, Annemarie Peen

    2015-01-01

    suggest that another operation in CAR may be underway shortly. The EU’s military endeavours are particularly interesting to this enquiry, as they suggest a radical change in the cohort of member states’ foreign policy towards the Union, which until the turn of the Millennium had been considered by its MS......, amongst others, as a predominantly ‘civilian power’. The significance of such a change merits a chapter that delves deeper into MS foreign policy specifically related to EU military operations.The rationale for this research is to further unpack intra-EU foreign policy and its effect on the external...

  2. Special considerations on operating a fuel cell power plant using natural gas with marginal heating value

    Energy Technology Data Exchange (ETDEWEB)

    Moses, L. Ng; Chien-Liang Lin [Industrial Technology Research Institute, Taiwan (China); Ya-Tang Cheng [Power Research Institute, Taiwan (China)

    1996-12-31

    In realizing new power generation technologies in Taiwan, a phosphoric acid fuel cell power plant (model PC2513, ONSI Corporation) has been installed in the premises of the Power Research Institute of the Taiwan Power Company in Taipei County of Taiwan. The pipeline gas supplying to the site of this power plant has a high percentage of carbon dioxide and thus a slightly lower heating value than that specified by the manufacturer. Because of the lowering of heating value of input gas, the highest Output power from the power plant is understandably less than the rated power of 200 kW designed. Further, the transient response of the power plant as interrupted from the Grid is also affected. Since this gas is also the pipeline gas supplying to the heavily populated Taipei Municipal area, it is conceivable that the success of the operations of fuel cells using this fuel is of vital importance to the promotion of the use of this power generation technology in Taiwan. Hence, experiments were set up to assess the feasibility of this fuel cell power plant using the existing pipeline gas in this part of Taiwan where fuel cells would most likely find useful.

  3. A Scheme for Atomic Entangled States and Quantum Gate Operations in Cavity QED

    Institute of Scientific and Technical Information of China (English)

    LI Peng-Bo; GU Ying; GONG Qi-Huang; GUO Guang-Can

    2009-01-01

    We propose a scheme for controllably entangling the ground states of five-state W-type atoms confined in a cavity and realizing swap gate and phase gate operations.In this scheme the cavity is only virtually excited and the atomic excited states are almost not occupied,so the produced entangled states and quantum logic operations are very robust against the cavity decay and atomic spontaneous emission.

  4. Properties of the Measurement Phase Operator in Dual-Mode Entangle Coherent States

    Institute of Scientific and Technical Information of China (English)

    HOU Shen-Yong; YANG Kuo

    2011-01-01

    @@ A class of measurement phase operators of dual-mode is defined and their properties in a class of entangle coherent states are investigated.Numerical results indicate that the entangle coherent states display some non-classical squeezed effects.%A class of measurement phase operators of dual-mode is defined and their properties in a class of entangle coherent states are investigated. Numerical results indicate that the entangle coherent states display some non-classical squeezed effects.

  5. Automation inflicted differences on operator performance in nuclear power plant control rooms

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Jonas; Osvalder, A.L. [Chalmers Univ. of Technology, Dept. of Product and Producton Development (Sweden)

    2007-03-15

    Today it is possible to automate almost any function in a human-machine system. Therefore it is important to find a balance between automation level and the prerequisites for the operator to maintain safe operation. Different human factors evaluation methods can be used to find differences between automatic and manual operations that have an effect on operator performance; e.g. Predictive Human Error Analysis (PHEA), NASA Task Load Index (NASA-TLX), Halden Questionnaire, and Human Error Assessment and Reduction Technique (HEART). Results from an empirical study concerning automation levels, made at Ringhals power plant, showed that factors as time pressure and criticality of the work situation influenced the operator's performance and mental workload more than differences in level of automation. The results indicate that the operator's attention strategies differ between the manual and automatic sequences. Independently of level of automation, it is essential that the operator retains control and situational understanding. When performing a manual task, the operator is 'closer' to the process and in control with sufficient situational understanding. When the level of automation increases, the demands on information presentation increase to ensure safe plant operation. The need for control can be met by introducing 'control gates' where the operator has to accept that the automatic procedures are continuing as expected. Situational understanding can be established by clear information about process status and by continuous feedback. A conclusion of the study was that a collaborative control room environment is important. Rather than allocating functions to either the operator or the system, a complementary strategy should be used. Key parameters to consider when planning the work in the control room are time constraints and task criticality and how they affect the performance of the joint cognitive system.However, the examined working

  6. Overview of United States Department of Energy activities to support life extension of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, D.L. [USDOE Assistant Secretary for Nuclear Energy, Washington, DC (United States). Office of LWR Safety and Technology; Rosinski, S.T. [Sandia National Labs., Albuquerque, NM (United States)

    1993-11-01

    Today, 109 nuclear power plants provide over 20 percent of the electrical energy generated in the US The operating license of the first of these plants will expire in the year 2000; one-third of the operating licenses will expire by 2010 and the remaining plant licenses are scheduled to expire by 2033. The National Energy Strategy assumes that 70 percent of these plants will continue to operate beyond their current license expiration to assist in ensuring an adequate, diverse, and environmentally acceptable energy supply for economic growth. In order to preserve this energy resource in the US three major tasks must be successfully completed: establishment of regulations, technical standards, and procedures for the preparation and review of a license renewal application; development, verification, and validation of technical criteria and bases for monitoring, refurbishing, and/or replacing plant equipment; and demonstration of the regulatory process. Since 1985, the US Department of Energy (DOE) has been working with the nuclear industry and the US Nuclear Regulatory Commission (NRC) to establish and demonstrate the option to extend the life of nuclear power plants through the renewal of operating licenses. This paper focuses primarily on DOE`s Plant Lifetime Improvement (PLIM) Program efforts to develop the technical criteria and bases for effective aging management and lifetime improvement for continued operation of nuclear power plants. This paper describes current projects to resolve generic technical issues in the principal areas of reactor pressure vessel (RPV) integrity, fatigue, and environmental qualification (EQ).

  7. Development and improvement of the operating diagnostics systems of NPO CKTI works for turbine of thermal and nuclear power plants

    Science.gov (United States)

    Kovalev, I. A.; Rakovskii, V. G.; Isakov, N. Yu.; Sandovskii, A. V.

    2016-03-01

    The work results on the development and improvement of the techniques, algorithms, and software-hardware of continuous operating diagnostics systems of rotating units and parts of turbine equipment state are presented. In particular, to ensure the full remote service of monitored turbine equipment using web technologies, the web version of the software of the automated systems of vibration-based diagnostics (ASVD VIDAS) was developed. The experience in the automated analysis of data obtained by ASVD VIDAS form the basis of the new algorithm of early detection of such dangerous defects as rotor deflection, crack in the rotor, and strong misalignment of supports. The program-technical complex of monitoring and measuring the deflection of medium pressure rotor (PTC) realizing this algorithm will alert the electric power plant staff during a deflection and indicate its value. This will give the opportunity to take timely measures to prevent the further extension of the defect. Repeatedly, recorded cases of full or partial destruction of shrouded shelves of rotor blades of the last stages of low-pressure cylinders of steam turbines defined the need to develop a version of the automated system of blade diagnostics (ASBD SKALA) for shrouded stages. The processing, analysis, presentation, and backup of data characterizing the mechanical state of blade device are carried out with a newly developed controller of the diagnostics system. As a result of the implementation of the works, the diagnosed parameters determining the operation security of rotating elements of equipment was expanded and the new tasks on monitoring the state of units and parts of turbines were solved. All algorithmic solutions and hardware-software implementations mentioned in the article were tested on the test benches and applied at some power plants.

  8. Nuclear power plant human computer interface design incorporating console simulation, operations personnel, and formal evaluation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Chavez, C.; Edwards, R.M.; Goldberg, J.H.

    1993-12-31

    New CRT-based information displays which enhance the human machine interface are playing a very important role and are being increasingly used in control rooms since they present a higher degree of flexibility compared to conventional hardwired instrumentation. To prototype a new console configuration and information display system at the Experimental Breeder Reactor II (EBR-II), an iterative process of console simulation and evaluation involving operations personnel is being pursued. Entire panels including selector switches and information displays are simulated and driven by plant dynamical simulations with realistic responses that reproduce the actual cognitive and physical environment. Careful analysis and formal evaluation of operator interaction while using the simulated console will be conducted to determine underlying principles for effective control console design for this particular group of operation personnel. Additional iterations of design, simulation, and evaluation will then be conducted as necessary.

  9. The Thermal-Hydraulic model for the pebble bed modular reactor (PBMR) plant operator training simulator system

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, Trevor [Pebble Bed Modular Reactor (Proprietary) Limited, Die Anker Building, Centurion 0046 (South Africa)], E-mail: trevor.dudley@pbmr.co.za; Bouwer, Werner; Villiers, Piet de [Pebble Bed Modular Reactor (Proprietary) Limited, Die Anker Building, Centurion 0046 (South Africa); Wang Zen [GSE Systems, Inc., 7133 Rutherford Suite 200, Baltimore, MD 21244 (United States)

    2008-11-15

    This paper provides a discussion of the model development status and verification efforts for the Reactor Core Thermal-Hydraulic model developed for the full-scope plant Operator Training Simulator System of the Pebble Bed Modular Reactor (PBMR). Due to the First of a Kind Engineering nature and lack of reference plant data, model verification has mainly been focused on benchmarking the model configurations against test cases performed by PBMR design analysis codes, i.e. TINTE, VSOP and FLOWNEX. As a first step, due to the symmetrical physical nature of the PBMR core, a two-dimensional (2D) model configuration in radial and axial directions (axial-symmetry) was developed. The design was subsequently extended to a three-dimensional (3D) configuration. Through the use of cross-flow and cross-conduction links, three nearly identical 2D configurations were glued together to form this 3D model configuration. To date, the 3D configuration represents the most comprehensive model to simulate the PBMR core thermo-hydraulics. This paper concludes with the verification of thermodynamic and heat-transfer properties of two steady state (100% and 40% power) conditions between the 3D Reactor Core Thermal-Hydraulic model and the available FLOWNEX and TINTE design code analysis. The transient operations between these two power levels are also discussed.

  10. Selecting Foreign Languages for United States Army Special Operations Forces

    Science.gov (United States)

    2006-06-16

    Portugal 170,000,000 7 RUSSIAN [RUS] Russia 170,000,000 8 JAPANESE [JPN] Japan 125,000,000 9 GERMAN, STANDARD [GER] Germany 98,000,000 10 CHINESE, WU...took place (Birtle 2004, Ch 2). Operations in Mexico, Cuba, Russia , and the Philippines are examples of US expeditionary forces deployed to areas...Department of the Army civilians, and retirees. The programs available are free of charge and are for either beginners or people seeking to increase or

  11. Operational Encirclements: Can the United States Military Decisively Follow Through?

    Science.gov (United States)

    2009-05-21

    friction that trickles down onto the battlefield. The European theatre during World War II was no different. The failure of American, and British...American and their Allied partners would continue to experience the ill-effects of it right up until the end of the war in the European theatre ...on Friday 27 March 2009 about Operation Anaconda. I used some information from our conversation. The following is verbatim from my monograph, "A

  12. The United States Army Operating Concept, 2016-2028

    Science.gov (United States)

    2010-08-19

    retrograde operations. f. Theater armies may also include a medical command for deployment support that provides health services to Army and other...tenets of jus in bello ,120 discrimination (between combatants and noncombatants), and proportionality in the use of force,121 measured against the...Barracks, PA, 19. (Used with permission.) 119 Biddle, 9. 120 Jus in bello , translated as justice in war, are agreements defining limits on acceptable

  13. Operator decision support system for integrated wastewater management including wastewater treatment plants and receiving water bodies.

    Science.gov (United States)

    Kim, Minsoo; Kim, Yejin; Kim, Hyosoo; Piao, Wenhua; Kim, Changwon

    2016-06-01

    An operator decision support system (ODSS) is proposed to support operators of wastewater treatment plants (WWTPs) in making appropriate decisions. This system accounts for water quality (WQ) variations in WWTP influent and effluent and in the receiving water body (RWB). The proposed system is comprised of two diagnosis modules, three prediction modules, and a scenario-based supporting module (SSM). In the diagnosis modules, the WQs of the influent and effluent WWTP and of the RWB are assessed via multivariate analysis. Three prediction modules based on the k-nearest neighbors (k-NN) method, activated sludge model no. 2d (ASM2d) model, and QUAL2E model are used to forecast WQs for 3 days in advance. To compare various operating alternatives, SSM is applied to test various predetermined operating conditions in terms of overall oxygen transfer coefficient (Kla), waste sludge flow rate (Qw), return sludge flow rate (Qr), and internal recycle flow rate (Qir). In the case of unacceptable total phosphorus (TP), SSM provides appropriate information for the chemical treatment. The constructed ODSS was tested using data collected from Geumho River, which was the RWB, and S WWTP in Daegu City, South Korea. The results demonstrate the capability of the proposed ODSS to provide WWTP operators with more objective qualitative and quantitative assessments of WWTP and RWB WQs. Moreover, the current study shows that ODSS, using data collected from the study area, can be used to identify operational alternatives through SSM at an integrated urban wastewater management level.

  14. Construction and operation of the flue gas desulphurization plant at Altbach/Deizisau power station, unit no. 5. Experience from commissioning and initial operating period

    Energy Technology Data Exchange (ETDEWEB)

    Maier, R.; Necker, P.; Strauss, J.; Hemming, H.; Landgraf, E.

    1987-04-01

    Since take-over the flue gas desulphurization plant has easily maintained the required level of desulphurisation. Caking-on and incrustation are substantially avoided. By redesigning the gypsum drying process an easily storable gypsum which can be used both in the gypsum and cement industry is produced. According to experience gained to date it is expected that the flue gas desulphurisation plant will not impair the availability of the power plant unit taking into account statutory regulations. In overall terms the plant has satisfactorily fulfilled the expectations of the operator.

  15. Utility Wind Integration and Operating Impact - State of the Art

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J. C.; Milligan, M. R.; DeMeo, E. A.; Parsons, B.

    2007-08-01

    At the end of 2005, the Power Engineering Society (PES) published a special issue of its Power & Energy Magazine that focused on integrating wind into the power system. This paper provides a summary and update on many of the salient points from that special issue about the current state of knowledge regarding utility wind integration issues.

  16. Operating System Support for High-Performance Solid State Drives

    DEFF Research Database (Denmark)

    Bjørling, Matias

    The performance of Solid State Drives (SSD) has evolved from hundreds to millions of I/Os per second in the past three years. Such a radical evolution is transforming both the storage and the software industries. Indeed, software designed based on the assumption of slow IOs has become...

  17. Mapping plant invadedness in watersheds across the continental United States

    Science.gov (United States)

    Exotic aquatic plant invasions trigger a cascade of negative effects, resulting in altered structure and function of freshwater ecosystems, loss of native biodiversity, and reduction of valuable ecosystem services such as recreation and water quality. The problem of biological in...

  18. Operation States Analysis of the Series-Parallel resonant Converter Working Above Resonance Frequency

    Directory of Open Access Journals (Sweden)

    Jaroslav Durdik

    2007-01-01

    Full Text Available Operation states analysis of a series-parallel converter working above resonance frequency is described in the paper. Principal equations are derived for individual operation states. On the basis of them the diagrams are made out. The diagrams give the complex image of the converter behaviour for individual circuit parameters. The waveforms may be utilised at designing the inverter individual parts.

  19. Thermal Wigner Operator in Coherent Thermal State Representation and Its Application

    Institute of Scientific and Technical Information of China (English)

    FANHong-Yi

    2002-01-01

    In the coherent thermal state representation we introduce thermal Wigner operator and find that it is “squeezed” under the thermal transformation.The thermal Wigner operator provides us with a new direct and neat approach for deriving Wigner functions of thermal states.

  20. Thermal Wigner Operator in Coherent Thermal State Representation and Its Application

    Institute of Scientific and Technical Information of China (English)

    FAN HongYi

    2002-01-01

    In the coherent thermal state representation we introduce thermal Wigner operator and find that it is"squeezed" under the thermal transformation. The thermal Wigner operator provides us with a new direct and neatapproach for deriving Wigner functions of thermal states.

  1. 300-FF-1 Operable Unit physical separation of soils pilot plant study

    Energy Technology Data Exchange (ETDEWEB)

    Freeman-Pollard, J.R.

    1994-01-15

    Alternative Remedial Technologies, Inc. (ART) was selected in a competitive selection process to conduct a pilot study for the physical separation of soils in the North Process Pond of the 300 Area at the Hanford Site. In January 1994, ART mobilized its 15 tons-per-hour pilot plant to the site. The plant was initially staged in a commercial area to allow for pretest inspections and minor modifications. The plant was specifically designed for use as a physical separations unit and consisted of a feed hopper, wet screens, hydrocyclones, as well as settling and dewatering equipment. The plant was supported in the field with prescreening equipment, mobile generators, air compressors, and water storage tanks. The plant was moved into the surface contamination area on March 24, 1994. The testing was conducted during the period March 23, 1994 through April 13, 1994. Two soil types were treated during the testing: a natural soil contaminated with low levels of uranium, cesium, cobalt, and heavy metals, and a natural soil contaminated with a uranium carbonate material that was visually recognizable by the presence of a green sludge material in the soil matrix. The ``green`` material contained significantly higher levels of the same contaminants. Both source materials were treated by the plant in a manner that fed the material, produced clean gravel and sand fractions, and concentrated the contaminants in a sludge cake. Process water was recycled during the operations. The testing was extremely successful in that for both source waste streams, it was demonstrated that volume reductions of greater than 90% could be achieved while also meeting the test performance criteria. The volume reduction for the natural soils averaged a 93.8%, while the ``green`` soils showed a 91.4% volume reduction.

  2. Ideal Operation of a Photovoltaic Power Plant Equipped with an Energy Storage System on Electricity Market

    Directory of Open Access Journals (Sweden)

    Markku Järvelä

    2017-07-01

    Full Text Available There is no natural inertia in a photovoltaic (PV generator and changes in irradiation can be seen immediately at the output power. Moving cloud shadows are the dominant reason for fast PV power fluctuations taking place typically within a minute between 20 to 100% of the clear sky value roughly 100 times a day, on average. Therefore, operating a utility scale grid connected PV power plant is challenging. Currently, in many regions, renewable energy sources such as solar and wind receive feed-in tariffs that ensure a certain price for the energy. On the other hand, electricity markets operate on a supply-demand principle and a typical imbalance settlement period is one hour. This paper presents the energy, power and corresponding requirements for an energy storage system in a solar PV power plant to feed the power to the grid meeting the electricity spot markets practices. An ideal PV energy production forecast is assumed to be available to define reference powers of the system for the studied imbalance settlement periods. The analysis is done for three different PV system sizes using the existing irradiance measurements of the Tampere University of Technology solar PV power station research plant.

  3. Survey of operation and maintenance-related materials needs in geothermal power plants

    Energy Technology Data Exchange (ETDEWEB)

    Allan, M.L.

    1998-06-01

    A survey was conducted to determine operation and maintenance (O and M)-related materials needs in geothermal power plants and to identify future research and development to address these needs. A total of 44 questionnaires was mailed to geothermal plant operators and industry consultants. The response rate was 54%. The participants were asked to describe type and frequency of materials problems, strategies currently used to mitigate such problems, barriers to using new or alternative materials and technologies, sources of information and give their views on research and development priorities. A wide range of opinions was obtained, reflecting each individual respondent`s perspective and the site-specific nature of some problems. However, the consensus is that corrosion and scaling remain major issues and that components requiring performance improvements include pipelines, well casing, turbines, heat exchangers, condensers, valves and cooling towers. It is recommended that appropriate research and development continue to be directed at reducing O and M costs associated with materials failure or inadequate service. There should be a balance between optimizing existing materials through better design and understanding of behavior in geothermal environments and development of new materials. Life extension of existing equipment, service life prediction, education of plant personnel in materials and methods for mitigating corrosion, and improvements in inhibitors and biocides would also be beneficial.

  4. SURVEY OF OPERATION AND MAINTENANCE-RELATED MATERIALS NEEDS IN GEOTHERMAL POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    ALLAN,M.L.

    1998-06-01

    A survey was conducted to determine operation and maintenance (O and M)-related materials needs in geothermal power plants and to identify future research and development to address these needs. A total of 44 questionnaires was mailed to geothermal plant operators and industry consultants. The response rate was 54%. The participants were asked to describe type and frequency of materials problems, strategies currently used to mitigate such problems, barriers to using new or alternative materials and technologies, sources of information and give their views research and development priorities. A. wide range of opinions was obtained, reflecting each individual respondent's perspective and the site-specific nature of some problems. However, the consensus is that corrosion and scaling remain major issues and that components requiring performance improvements include pipelines, well casing, turbines, heat exchangers, condensers, valves and cooling towers. It is recommended that appropriate research and development continue to be directed at reducing O and M costs associated with materials failure or inadequate service. There should be a balance between optimizing existing materials through better design and understanding of behavior in geothermal environments and development of new materials. Life extension of existing equipment, service life prediction, education of plant personnel in materials and methods for mitigating corrosion, and improvements in inhibitors and biocides would also be beneficial.

  5. Performance analysis of monary and binary geothermal power plants operation for Ukraine conditions

    Directory of Open Access Journals (Sweden)

    Аlla Е. Denysova

    2015-03-01

    Full Text Available Every day the shortage in natural gas and coal does increase. In this respect, a great attention is paid to alternative energy sources, and geothermal electrical power generation represents one of the most cost-effective technologies. New power generation technologies using geothermal resources are ecologically clean and are close approaching to traditional ones from the efficiency point of view. This research aim is to analyze the efficiency of monary and binary geothermal power plants operation under actual conditions in Ukraine. Authors discuss prospects for the geothermal power engineering development in Ukraine and other countries. The principal thermal diagrams of monary and binary power plants are represented, as well as their operational principle considering these schemes advantages and disadvantages. Effected is an analysis of such stations performances under conditions of Ukraine. This research value and practical significance are related to the fact that for Ukraine both monary and binary geothermal power plants are very promising, but each engineering solutions should strictly follow its specific functional conditions.

  6. Simulation of a Martian Solar Thermal Power Plant - Diurnal Operation and Power-Efficiency Correlations

    Science.gov (United States)

    Badescu, V.; Popescu, G.; Feidt, M.

    A solar thermal power plant operating on Mars surface is analyzed in this work. During analysis meteorological data measured at Viking Landers (VL) sites were used. Our results show that during autumn at VL1 site, properly designed thermal power plant based on flat - plate solar collectors are comparable in performance with PV- based power systems. During a winter dust-storm day the maximum output power is much smaller than during autumn. High efficiency thermal engines is recommended to be used in combination with solar collectors kept perpendicular on Sun's rays. When a horizontal solar collector is considered, the dependence of the maximum output power on optimum solar efficiency seems to be quadratic at both VL1 and VL2 sites. When a collector perpendicular on Sun's rays is considered, this dependence is more complicate, but keeps the quadratic feature. A certain optimum solar efficiency threshold (around 5%) must be exceeded in order the system provide useful power. No obvious difference exists between power plant performance in the two years of VL2 operation.

  7. Survey of operation and maintenance-related materials needs in geothermal power plants

    Energy Technology Data Exchange (ETDEWEB)

    Allan, M.L.

    1998-06-01

    A survey was conducted to determine operation and maintenance (O and M)-related materials needs in geothermal power plants and to identify future research and development to address these needs. A total of 44 questionnaires was mailed to geothermal plant operators and industry consultants. The response rate was 54%. The participants were asked to describe type and frequency of materials problems, strategies currently used to mitigate such problems, barriers to using new or alternative materials and technologies, sources of information and give their views on research and development priorities. A wide range of opinions was obtained, reflecting each individual respondent`s perspective and the site-specific nature of some problems. However, the consensus is that corrosion and scaling remain major issues and that components requiring performance improvements include pipelines, well casing, turbines, heat exchangers, condensers, valves and cooling towers. It is recommended that appropriate research and development continue to be directed at reducing O and M costs associated with materials failure or inadequate service. There should be a balance between optimizing existing materials through better design and understanding of behavior in geothermal environments and development of new materials. Life extension of existing equipment, service life prediction, education of plant personnel in materials and methods for mitigating corrosion, and improvements in inhibitors and biocides would also be beneficial.

  8. SURVEY OF OPERATION AND MAINTENANCE-RELATED MATERIALS NEEDS IN GEOTHERMAL POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    ALLAN,M.L.

    1998-06-01

    A survey was conducted to determine operation and maintenance (O and M)-related materials needs in geothermal power plants and to identify future research and development to address these needs. A total of 44 questionnaires was mailed to geothermal plant operators and industry consultants. The response rate was 54%. The participants were asked to describe type and frequency of materials problems, strategies currently used to mitigate such problems, barriers to using new or alternative materials and technologies, sources of information and give their views research and development priorities. A. wide range of opinions was obtained, reflecting each individual respondent's perspective and the site-specific nature of some problems. However, the consensus is that corrosion and scaling remain major issues and that components requiring performance improvements include pipelines, well casing, turbines, heat exchangers, condensers, valves and cooling towers. It is recommended that appropriate research and development continue to be directed at reducing O and M costs associated with materials failure or inadequate service. There should be a balance between optimizing existing materials through better design and understanding of behavior in geothermal environments and development of new materials. Life extension of existing equipment, service life prediction, education of plant personnel in materials and methods for mitigating corrosion, and improvements in inhibitors and biocides would also be beneficial.

  9. Plan for the Startup of HA-21I Furnace Operations at the Plutonium Finishing Plant (PFP)

    Energy Technology Data Exchange (ETDEWEB)

    WILLIS, H.T.

    2000-02-17

    Achievement of Thermal Stabilization mission elements require the installation and startup of three additional muffle furnaces for the thermal stabilization of plutonium and plutonium bearing materials at the Plutonium Finishing Plant (PFP). The release to operate these additional furnaces will require an Activity Based Startup Review. The conduct of the Activity Based Startup Review (ABSR) was approved by Fluor Daniel Hanford on October 15, 1999. This plan has been developed with the objective of identifying those activities needed to guide the controlled startup of five furnaces from authorization to unrestricted operations by adding the HA-211 furnaces in an orderly and safe manner after the approval to Startup has been given. The Startup Plan provides a phased approach that bridges the activities between the completion of the Activity Based Startup Review authorizing the use of the three additional furnaces and the unrestricted operation of the five thermal stabilization muffle furnaces. The four phases are: (1) the initiation of five furnace operations using three empty (simulated full) boat charges from HA-211 and two full charges from HC-21C; (2) three furnace operations (one full charge from HA-211 and two full charges from HC-21C); (3) four furnace operations (two full charges from HA-211 and two full charges from HC-21C); and (4) integrated five furnace operations and unrestricted operations. Phase 1 of the Plan will be considered as the cold runs. This Plan also provides management oversight and administrative controls that are to be implemented until unrestricted operations are authorized. It also provides a formal review process for ensuring that all preparations needed for full five furnace operations are completed and formally reviewed prior to proceeding to the increased activity levels associated with five furnace operations. Specific objectives include: (1) To ensure that activities are conducted in a safe manner. (2) To provide supplemental

  10. Analysis of the Impact of Decreasing District Heating Supply Temperature on Combined Heat and Power Plant Operation

    Directory of Open Access Journals (Sweden)

    Bolonina Alona

    2014-12-01

    Full Text Available District heating systems are widely used to supply heat to different groups of heat consumers. The district heating system offers great opportunities for combined heat and power production. In this paper decreasing district heating supply temperature is analysed in the context of combined heat and power plant operation. A mathematical model of a CHP plant is developed using both empirical and theoretical equations. The model is used for analysis of modified CHP plant operation modes with reduced district heating supply temperature. Conclusions on the benefits of new operation modes are introduced.

  11. Plant research '79: report of the Michigan State University, Department of Energy, Plant Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    Botanical research conducted at MSU during 1979 is described. Areas of study include cell wall biosynthesis, hormonal regulation, responses of plants to environmental stresses, and molecular studies. (ACR)

  12. Aging influence on exergy destruction in an operating 320MW steam power plant

    Science.gov (United States)

    Salari, Sina; Abroshan, Hamid

    2012-06-01

    Exergy analysis in power plants is a strong tool to evaluate cycle performance qualitatively. Most of previous studies applied second law approach to find optimum values for main cycle parameters. Although, these researches are useful to improve the design features of future power plants, they do not imply any recommendation to improve an aged unit. In This study an exergy analysis of an operating unit was performed to clear main sources of exergy destruction. Second law efficiency and exergy losses of all main components in the steam power plant, which is located in the south of Iran, were calculated based on present data. To find out aging influence on the plant performance, outcomes were compared with design results. This comparison cleared components which affected by aging, and the amount of miss performance were specified too. Boiler and high pressure turbine (HP) were the most influenced components due to aging effects. Besides, the calculations were done at three loads in order to evaluate performance of components in off design conditions.

  13. Arbitrary multimode Gaussian operations on mechanical cluster states

    Science.gov (United States)

    Moore, Darren W.; Houhou, Oussama; Ferraro, Alessandro

    2017-08-01

    We consider opto- and electromechanical quantum systems composed of a driven cavity mode interacting with a set of mechanical resonators. It has been proposed that the latter can be initialized in arbitrary cluster states, including universal resource states for measurement-based quantum computation (MBQC). We show that, despite the unavailability in this setup of direct measurements over the mechanical resonators, computation can still be performed to a high degree of accuracy. In particular, it is possible to indirectly implement the measurements necessary for arbitrary Gaussian MBQC by properly coupling the mechanical resonators to the cavity field and continuously monitoring the leakage of the latter. We provide a thorough theoretical analysis of the performances obtained via indirect measurements, comparing them with what is achievable when direct measurements are instead available. We show that high levels of fidelity are attainable in parameter regimes within reach of present experimental capabilities.

  14. Symplectic Group Representation of the Two-Mode Squeezing Operator in the Coherent State Basis

    Institute of Scientific and Technical Information of China (English)

    FAN Hong-Yi; CHEN Jun-Hua

    2003-01-01

    We find that the coherent state projection operator representation of the two-mode squeezing operator constitutes a loyal group representation of symplectic group, which is a remarkable property of the coherent state. As a consequence, the resultant effect of successively applying two-mode squeezing operators are equivalent to a single squeezing in the two-mode Fock space. Generalization of this property to the 2n-mode case is also discussed.

  15. United States Department of Energy, Nevada Operations Office, completion report Operation KLAXON, Fiscal Year 1993

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    The U.S. Department of Energy, Nevada Operations Office (DOE/NV), Completion Report provides a summary of activities conducted at the Nevada Test Site (NTS) between October 1, 1992, and September 30, 1993, associated with Operation KLAXON. (In the past, each annual Completion Report dealt with a series of underground nuclear detonations; however, because no nuclear tests were conducted during FY 1993, this Report summarizes continuing nonnuclear and nuclear test readiness activities at the NTS sponsored by DOE/NV.) The report serves as a reference for those involved with the planning and execution of Operation KLAXON and also serves as a planning guide for future operations. Information in the report covers the logistics and management of activities. Scientific information and data associated with NTS activities are presented in technical documents published by participating agencies. In September 1992, Congress legislated a nine-month moratorium on the testing of nuclear weapons. The bill also provided for a resumption of testing (with no more than five tests per year, or a total of 15 during the next three years) in July 1993, and mandated an end to nuclear testing, entirely, by 1996. President Bush signed the bill into law in October 1992.

  16. Operating test report for project W-417, T-plant steam removal upgrade, waste transfer portion

    Energy Technology Data Exchange (ETDEWEB)

    Myers, N.K.

    1997-10-21

    This Operating Test Report (OTR) documents the performance results of the Operating Test Procedure HNF-SD-W417-OTP-001 that provides steps to test the waste transfer system installed in the 221-T Canyon under project W-417. Recent modifications have been performed on the T Plant Rail Car Waste Transfer System. This Operating Test Procedure (OTP) will document the satisfactory operation of the 221-T Rail Car Waste Transfer System modified by project W-417. Project W-417 installed a pump in Tank 5-7 to replace the steam jets used for transferring liquid waste. This testing is required to verify that operational requirements of the modified transfer system have been met. Figure 2 and 3 shows the new and existing system to be tested. The scope of this testing includes the submersible air driven pump operation in Tank 5-7, liquid waste transfer operation from Tank 5-7 to rail car (HO-IOH-3663 or HO-IOH-3664), associated line flushing, and the operation of the flow meter. This testing is designed to demonstrate the satisfactory operation-of the transfer line at normal operating conditions and proper functioning of instruments. Favorable results will support continued use of this system for liquid waste transfer. The Functional Design Criteria for this system requires a transfer flow rate of 40 gallons per minute (GPM). To establish these conditions the pump will be supplied up to 90 psi air pressure from the existing air system routed in the canyon. An air regulator valve will regulate the air pressure. Tank capacity and operating ranges are the following: Tank No. Capacity (gal) Operating Range (gal) 5-7 10,046 0 8040 (80%) Rail car (HO-IOH-3663 HO-IOH-3664) 097219,157 Existing Tank level instrumentation, rail car level detection, and pressure indicators will be utilized for acceptance/rejection Criteria. The flow meter will be verified for accuracy against the Tank 5-7 level indicator. The level indicator is accurate to within 2.2 %. This will be for information only

  17. Key Parameters for Operator Diagnosis of BWR Plant Condition during a Severe Accident

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A [ORNL; Poore III, Willis P [ORNL

    2015-01-01

    The objective of this research is to examine the key information needed from nuclear power plant instrumentation to guide severe accident management and mitigation for boiling water reactor (BWR) designs (specifically, a BWR/4-Mark I), estimate environmental conditions that the instrumentation will experience during a severe accident, and identify potential gaps in existing instrumentation that may require further research and development. This report notes the key parameters that instrumentation needs to measure to help operators respond to severe accidents. A follow-up report will assess severe accident environmental conditions as estimated by severe accident simulation model analysis for a specific US BWR/4-Mark I plant for those instrumentation systems considered most important for accident management purposes.

  18. Optimization of CCGT power plant and performance analysis using MATLAB/Simulink with actual operational data.

    Science.gov (United States)

    Hasan, Naimul; Rai, Jitendra Nath; Arora, Bharat Bhushan

    2014-01-01

    In the Modern scenario, the naturally available resources for power generation are being depleted at an alarming rate; firstly due to wastage of power at consumer end, secondly due to inefficiency of various power system components. A Combined Cycle Gas Turbine (CCGT) integrates two cycles- Brayton cycle (Gas Turbine) and Rankine cycle (Steam Turbine) with the objective of increasing overall plant efficiency. This is accomplished by utilising the exhaust of Gas Turbine through a waste-heat recovery boiler to run a Steam Turbine. The efficiency of a gas turbine which ranges from 28% to 33% can hence be raised to about 60% by recovering some of the low grade thermal energy from the exhaust gas for steam turbine process. This paper is a study for the modelling of CCGT and comparing it with actual operational data. The performance model for CCGT plant was developed in MATLAB/Simulink.

  19. Model-Based Analysis and Efficient Operation of a Glucose Isomerization Reactor Plant

    DEFF Research Database (Denmark)

    2015-01-01

    efficiency. The objective of this study is the application of the developed framework on an industrial case study of a glucose isomerization (GI) reactor plant that is part of a corn refinery, with the objective to improve the productivity of the process. Therefore, a multi-scale reactor model......The application of computer-aided model based methods within an integrated systematic framework is illustrated with the objective to assist the multi-purpose pharmaceutical/biochemical industry to systematically solve the complex problems that are experienced when aiming at improving the process...... is developedfor use as a building block for the GI reactor plant simulation. An optimal operation strategy is proposed on the basis of the simulation results...

  20. Construction and operation of biogas plants. Bau und Betrieb von Biogasanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, F. von

    1985-01-01

    Biogas utilisation in agriculture has increased considerably as a consequence of the energy crisis. So far, energy production was the most important aspect, and the high-quality natural fertilizer offered by the fermentation residues was commonly neglected. This fertilizer is an effective substitute for commercial fertilizers and thus contributes to the reduction of environmental pollution. The book discusses the chemical and biological mechanisms, the criteria of selection for plants and materials, optimum gas production techniques, uses of the product gas, and the advantages and properties of the biofertilizer produced. Planning procedures, design, construction, function and performance of several biogas production plants now in operation are described. Hints are given for do-it-yourself construction, as are cost-benefit calculations and decision aids for construction.

  1. Operational safety analysis of the Olkiluoto encapsulation plant and disposal facility; Olkiluodon kapselointi- ja loppusijoituslaitoksen kaeyttoeturvallisuusanalyysi

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, J.; Suolanen, V. [VTT Technical Research Centre of Finland, Espoo (Finland)

    2012-11-15

    Radiation doses for workers of the facility, for inhabitants in the environment and for terrestrial ecosystem possibly caused by the encapsulation and disposal facilities to be built at Olkiluoto during its operation were considered in the study. The study covers both the normal operation of the plant and some hypothetical incidents and accidents. Release through the ventilation stack is assumed to be filtered both in normal operation and in hypothetical abnormal fault and accident cases. In addition the results for unfiltered releases are also presented. This research is limited to the deterministic analysis. During about 30 operation years of our four nuclear power plant units there have been found 58 broken fuel pins. Roughly estimating there has been one fuel leakage per year in a facility (includes two units). Based on this and adopting a conservative approach, it is estimated that one fuel pin per year could leak in normal operation during encapsulation process. The release magnitude in incidents and accidents is based on the event chains, which lead to loss of fuel pin tightness followed by a discharge of radionuclides into the handling space and to some degree to the atmosphere through the ventilation stack equipped with redundant filters. The most exposed group of inhabitants is conservatively assumed to live at the distance of 200 meters from the encapsulation and disposal plant and it will receive the largest doses in most dispersion conditions. The dose value to a member of the most exposed group was calculated on the basis of the weather data in such a way that greater dose than obtained here is caused only in 0.5 percent of dispersion conditions. The results obtained indicate that during normal operation the doses to workers remain small and the dose to the member of the most exposed group is less than 0.001 mSv per year. In the case of hypothetical fault and accident releases the offsite doses do not exceed either the limit values set by the safety

  2. Comparing Two Operating Configurations in a Full-Scale Arsenic Removal Plant. Case Study: Guatemala

    Directory of Open Access Journals (Sweden)

    Sofía E. Garrido Hoyos

    2013-06-01

    Full Text Available The present study was conducted in Naranjo County located in the municipality of Mixco, Guatemala. The water supply source comes from two wells with a maximum flow of 25.24 and 33.44 L·s−1. The main problem with this source is the high arsenic concentration—between 0.1341 and 0.1671 mg·L−1. The aim of this study was to conduct laboratory tests, basic engineering and supervision of the construction and evaluation of an operations plant using two configurations, A (low-rate sedimentation and ceramic filter and B (high-rate sedimentation and clinoptilolite filter, to remove arsenic present in water for human use and consumption. This plant supplies water to Naranjo County in Mixco, Guatemala (5000 inhabitants. First, a laboratory Jar Test was performed to evaluate arsenic removal efficiency. And second, a conventional clarification plant was then built (design flow: 25.24 L·s−1. The best results were achieved with configuration B, with the following reagents and dosage as defined by the laboratory tests: 10 mg L−1 ferric chloride as coagulant; 1.8 mg·L−1 CH-polyfocal as flocculant and 0.4 mg L−1 MIT03 as color removal; 1 mg L−1 sodium hypochlorite as oxidant and adjusting pH to ≈7.0 with sodium hydroxide. Once the plant began operating, the efficiency of the treatment process was evaluated. The maximum elimination efficiencies were obtained 100% for turbidity (0 UTN, 89.54% (3.66 UPt-Co for color and 96.80% (0.005 mg L−1 for arsenic, values that comply with Guatemalan standards. For this case, the relation between Fe(III dosage/mg and As(V removal was 1:46.

  3. Operational readiness verification, phase 1: A study on safety during outage and restart of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hollnagel, E. [Linkoeping Univ. (Sweden). Dept. of Computer and Information Science; Gauthereau, V. [Linkoeping Univ. (Sweden). Dept. of Industrial Engineering

    2001-06-01

    This report contains the findings from the first phase of a study on safety during outage and restart of nuclear power plants. Operational Readiness Verification (ORV) - in Swedish called Driftklarhetsverifiering (DKV) - refers to the test and verification activities that are necessary to ensure that plant systems are able to provide their required functions when needed - more concretely that all plant systems are in their correct functional state when the plant is restarted after an outage period. The concrete background for this work is that nine ORV related incidents were reported in Sweden between July 1995 and October 1998. The work reported here comprised a literature survey of research relevant for ORV issues, and an assessment of the present situation at Swedish NPPs with respect to ORV. The literature survey was primarily aimed at research related to NPPs, but also looked at domains where similar problems have occurred, such as maintenance in commercial aviation. The survey looked specifically for organisational and MTO aspects relevant to the present situation in Swedish NPPs. One finding was that ORV should be seen as an integral part of maintenance, rather than as a separate activity. Another, that there is a characteristic distribution of error modes for maintenance and ORV, with many sequence errors and omissions, rather than a set of unique error modes. An international study further showed that there are important differences in how procedures are used, and in the balance between decentralisation and centralisation. Several studies also suggested that ORV could usefully be described as a barrier system in relation to the flow of work, for instance using the following five stages: (1) preventive actions during maintenance/outage, (2) post-test after completion of work, (3) pre-test before start-up, (4) the start-up sequence itself, and (5) preventive actions during power operation - possibly including automatic safety systems. In the field survey

  4. Matrix Product Operators, Matrix Product States, and ab initio Density Matrix Renormalization Group algorithms

    CERN Document Server

    Chan, Garnet Kin-Lic; Nakatani, Naoki; Li, Zhendong; White, Steven R

    2016-01-01

    Current descriptions of the ab initio DMRG algorithm use two superficially different languages: an older language of the renormalization group and renormalized operators, and a more recent language of matrix product states and matrix product operators. The same algorithm can appear dramatically different when written in the two different vocabularies. In this work, we carefully describe the translation between the two languages in several contexts. First, we describe how to efficiently implement the ab-initio DMRG sweep using a matrix product operator based code, and the equivalence to the original renormalized operator implementation. Next we describe how to implement the general matrix product operator/matrix product state algebra within a pure renormalized operator-based DMRG code. Finally, we discuss two improvements of the ab initio DMRG sweep algorithm motivated by matrix product operator language: Hamiltonian compression, and a sum over operators representation that allows for perfect computational par...

  5. Characterising of solid state electrochemical cells under operation

    DEFF Research Database (Denmark)

    Holtappels, Peter

    2014-01-01

    Compared to significant progress in PEMFC especially regarding the utilization of complex fuels such as methanol significant progress has been made by applying spectroscopic / differential IR and spectrometric techniques to working fuel cells, the processes in solid state high temperature...... electrochemical cells are still a "black box". In order to identify local reaction sites, surface coverage and potential/current introduced materials and surface modifications, in situ techniques are needed to gain a better understanding of the elementary and performance limiting steps for these cells...

  6. Characterising of solid state electrochemical cells under operation

    DEFF Research Database (Denmark)

    Holtappels, Peter

    2014-01-01

    Compared to significant progress in PEMFC especially regarding the utilization of complex fuels such as methanol significant progress has been made by applying spectroscopic / differential IR and spectrometric techniques to working fuel cells, the processes in solid state high temperature....... This relates to interrelation between NOx/ O2 on cathodes but also to sulfur and carbon exposure at the anode. Past and recent activities on SOFC anodes and cathodes will be presented as well as perspectives and gaps discussed for these systems. Especially interaction between sulfur interactions with solids...

  7. The Fermionic Signature Operator and Hadamard States in the Presence of a Plane Electromagnetic Wave

    CERN Document Server

    Finster, Felix

    2016-01-01

    We give a non-perturbative construction of a distinguished state for the quantized Dirac field in Minkowski space in the presence of a time-dependent external field of the form of a plane electromagnetic wave. By explicit computation of the fermionic signature operator, it is shown that the Dirac operator has the strong mass oscillation property. We prove that the resulting fermionic projector state is a Hadamard state.

  8. Hospital markup and operation outcomes in the United States.

    Science.gov (United States)

    Gani, Faiz; Ejaz, Aslam; Makary, Martin A; Pawlik, Timothy M

    2016-07-01

    Although the price hospitals charge for operations has broad financial implications, hospital pricing is not subject to regulation. We sought to characterize national variation in hospital price markup for major cardiothoracic and gastrointestinal operations and to evaluate perioperative outcomes of hospitals relative to hospital price markup. All hospitals in which a patient underwent a cardiothoracic or gastrointestinal procedure were identified using the Nationwide Inpatient Sample for 2012. Markup ratios (ratio of charges to costs) for the total cost of hospitalization were compared across hospitals. Risk-adjusted morbidity, failure-to-rescue, and mortality were calculated using multivariable, hierarchical logistic regression. Among the 3,498 hospitals identified, markup ratios ranged from 0.5-12.2, with a median markup ratio of 2.8 (interquartile range 2.7-3.9). For the 888 hospitals with extreme markup (greatest markup ratio quartile: markup ratio >3.9), the median markup ratio was 4.9 (interquartile range 4.3-6.0), with 10% of these hospitals billing more than 7 times the Medicare-allowable costs (markup ratio ≥7.25). Extreme markup hospitals were more often large (46.3% vs 33.8%, P markup ratio compared with 19.3% (n = 452) and 6.8% (n = 35) of nonprofit and government hospitals, respectively. Perioperative morbidity (32.7% vs 26.4%, P markup hospitals. There is wide variation in hospital markup for cardiothoracic and gastrointestinal procedures, with approximately a quarter of hospital charges being 4 times greater than the actual cost of hospitalization. Hospitals with an extreme markup had greater perioperative morbidity. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Optimization of the weekly operation of a multipurpose hydroelectric development, including a pumped storage plant

    Energy Technology Data Exchange (ETDEWEB)

    Popa, R; Popa, B [Faculty of Power Engineering, University Politehnica of Bucharest, 313 Spl. Independentei, sect. 6, Bucharest, 060042 (Romania); Popa, F [Institute for Hydropower Studies and Design, 5-7 Vasile Lascar, sect. 2, Bucharest, 020491 (Romania); Zachia-Zlatea, D, E-mail: bogdan.popa@rosha.r [Hidroelectrica S.A., 3 Constantin Nacu, sect. 2, Bucharest, 020995 (Romania)

    2010-08-15

    It is presented an optimization model based on genetic algorithms for the operation of a multipurpose hydroelectric power development consisting in a pumped storage plant (PSP) with weekly operation cycle. The lower reservoir of the PSP is supplied upstream from a peak hydropower plant (HPP) with a large reservoir and supplies the own HPP which provides the required discharges towards downstream. Under these conditions, the optimum operation of the assembly consisting in 3 reservoirs and hydropower plants becomes a difficult problem if there are considered the restrictions as regards: the gradients allowed for the reservoirs filling/emptying, compliance with of a long-term policy of the upper reservoir from the hydroelectric development and of the weekly cycle for the PSP upper reservoir, correspondence between the power output/consumption in the weekly load schedule, turning to account of the water resource at maximum overall efficiencies, etc. Maximization of the net energy value (generated minus consumed) was selected as performance function of the model, considering the differentiated price of the electric energy over the week (working or weekend days, peak, half-peak or base hours). The analysis time step was required to be of 3 hours, resulting a weekly horizon of 56 steps and 168 decision variables, respectively, for the 3 HPPs of the system. These were allowed to be the flows turbined at the HPP and the number of working hydrounits at PSP, on each time step. The numerical application has considered the guiding data of Fantanele-Tarnita-Lapustesti hydroelectric development. Results of various simulations carried out proved the qualities of the proposed optimization model, which will allow its use within a decisional support program for such a development.

  10. Optimization of the weekly operation of a multipurpose hydroelectric development, including a pumped storage plant

    Science.gov (United States)

    Popa, R.; Popa, F.; Popa, B.; Zachia-Zlatea, D.

    2010-08-01

    It is presented an optimization model based on genetic algorithms for the operation of a multipurpose hydroelectric power development consisting in a pumped storage plant (PSP) with weekly operation cycle. The lower reservoir of the PSP is supplied upstream from a peak hydropower plant (HPP) with a large reservoir and supplies the own HPP which provides the required discharges towards downstream. Under these conditions, the optimum operation of the assembly consisting in 3 reservoirs and hydropower plants becomes a difficult problem if there are considered the restrictions as regards: the gradients allowed for the reservoirs filling/emptying, compliance with of a long-term policy of the upper reservoir from the hydroelectric development and of the weekly cycle for the PSP upper reservoir, correspondence between the power output/consumption in the weekly load schedule, turning to account of the water resource at maximum overall efficiencies, etc. Maximization of the net energy value (generated minus consumed) was selected as performance function of the model, considering the differentiated price of the electric energy over the week (working or weekend days, peak, half-peak or base hours). The analysis time step was required to be of 3 hours, resulting a weekly horizon of 56 steps and 168 decision variables, respectively, for the 3 HPPs of the system. These were allowed to be the flows turbined at the HPP and the number of working hydrounits at PSP, on each time step. The numerical application has considered the guiding data of Fantanele-Tarnita-Lapustesti hydroelectric development. Results of various simulations carried out proved the qualities of the proposed optimization model, which will allow its use within a decisional support program for such a development.

  11. Photoreceptor effects on plant biomass, resource allocation, and metabolic state.

    Science.gov (United States)

    Yang, Deyue; Seaton, Daniel D; Krahmer, Johanna; Halliday, Karen J

    2016-07-05

    Plants sense the light environment through an ensemble of photoreceptors. Members of the phytochrome class of light receptors are known to play a critical role in seedling establishment, and are among the best-characterized plant signaling components. Phytochromes also regulate adult plant growth; however, our knowledge of this process is rather fragmented. This study demonstrates that phytochrome controls carbon allocation and biomass production in the developing plant. Phytochrome mutants have a reduced CO2 uptake, yet overaccumulate daytime sucrose and starch. This finding suggests that even though carbon fixation is impeded, the available carbon resources are not fully used for growth during the day. Supporting this notion, phytochrome depletion alters the proportion of day:night growth. In addition, phytochrome loss leads to sizeable reductions in overall growth, dry weight, total protein levels, and the expression of CELLULOSE SYNTHASE-LIKE genes. Because cellulose and protein are major constituents of plant biomass, our data point to an important role for phytochrome in regulating these fundamental components of plant productivity. We show that phytochrome loss impacts core metabolism, leading to elevated levels of tricarboxylic acid cycle intermediates, amino acids, sugar derivatives, and notably the stress metabolites proline and raffinose. Furthermore, the already growth-retarded phytochrome mutants are less responsive to growth-inhibiting abiotic stresses and have elevated expression of stress marker genes. This coordinated response appears to divert resources from energetically costly biomass production to improve resilience. In nature, this strategy may be activated in phytochrome-disabling, vegetation-dense habitats to enhance survival in potentially resource-limiting conditions.

  12. Thermodynamic analysis of an upstream petroleum plant operated on a mature field

    DEFF Research Database (Denmark)

    Nguyen, Tuong-Van; Jacyno, Tomasz; Breuhaus, Peter

    2014-01-01

    %) and production manifold (10%) modules. The separation work performed on this platform is greater than in similar facilities because of higher propane and water fractions of the well-streams. These findings emphasise the differences between peak and end-life productions: they suggest (i) to set focus on processes......Oil and gas processing on offshore platforms operates under changing boundary conditions over a field lifespan, as the hydrocarbon production declines and the water extraction increases. In this paper, the processing plant of the Draugen platform is evaluated by performing an energy and exergy...

  13. Significant savings with an advanced forecasting system[Process plant operation

    Energy Technology Data Exchange (ETDEWEB)

    Rorie, George [Shell Expro (United Kingdom)

    1999-07-01

    The article expounds the value of Gensym's G2 real-time expert software which schedules and optimises operations in process plants. G2 can detect problems early and give advice on solutions: it converts masses of production, process and commercial data into intelligent information by capturing and applying knowledge and experience. G2 is now used by more than 100 gas and oil companies and is said to be the industry standard for creating intelligent systems. Shell Expro's experience with G2 is discussed in detail.

  14. The Conversion of a Zimbabwean Processing Plant from Manual to Smart Operation

    Institute of Scientific and Technical Information of China (English)

    Michael; Collier; Ernest; Bhero

    2010-01-01

    <正>The automation of several key processes in a factory in Zimbabwe is described.The plant is a producer of bolts and nails for the southern Africa region.Being built in the 1950s,the equipment was intended for manual operation.To improve efficiency and reduce overhead costs, this project was commissioned to add electronic intelligence to some of the processing equipment.In particular the conversion of forging furnaces to computer control and the intelligent implementation of heat-treatment processes are described.Results of the project in economic and quality terms are presented.

  15. Verification of electromagnetic effects from wireless devices in operating nuclear power plants

    Directory of Open Access Journals (Sweden)

    Song-Hae Ye

    2015-10-01

    Full Text Available Wireless communication technologies, especially smartphones, have become increasingly common. Wireless technology is widely used in general industry and this trend is also expected to grow with the development of wireless technology. However, wireless technology is not currently applied in any domestic operating nuclear power plants (NPPs because of the highest priority of the safety policy. Wireless technology is required in operating NPPs, however, in order to improve the emergency responses and work efficiency of the operators and maintenance personnel during its operation. The wired telephone network in domestic NPPs can be simply connected to a wireless local area network to use wireless devices. This design change can improve the ability of the operators and personnel to respond to an emergency situation by using important equipment for a safe shutdown. IEEE 802.11 smartphones (Wi-Fi standard, Internet Protocol (IP phones, personal digital assistant (PDA for field work, notebooks used with web cameras, and remote site monitoring tablet PCs for on-site testing may be considered as wireless devices that can be used in domestic operating NPPs. Despite its advantages, wireless technology has only been used during the overhaul period in Korean NPPs due to the electromagnetic influence of sensitive equipment and cyber security problems. This paper presents the electromagnetic verification results from major sensitive equipment after using wireless devices in domestic operating NPPs. It also provides a solution for electromagnetic interference/radio frequency interference (EMI/RFI from portable and fixed wireless devices with a Wi-Fi communication environment within domestic NPPs.

  16. Verification of electromagnetic effects from wireless devices in operating nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Song Hae; Kim, Young Sik; Lyou, Ho Sun; Kim, Min Suk [Korea Hydro and Nuclear Power Co. (KHNP), Central Research Institute, Daejeon (Korea, Republic of); Lyou, Joon [Dept. of Electronics Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2015-10-15

    Wireless communication technologies, especially smart phones, have become increasingly common. Wireless technology is widely used in general industry and this trend is also expected to grow with the development of wireless technology. However, wireless technology is not currently applied in any domestic operating nuclear power plants (NPPs) because of the highest priority of the safety policy. Wireless technology is required in operating NPPs, however, in order to improve the emergency responses and work efficiency of the operators and maintenance personnel during its operation. The wired telephone network in domestic NPPs can be simply connected to a wireless local area network to use wireless devices. This design change can improve the ability of the operators and personnel to respond to an emergency situation by using important equipment for a safe shutdown. IEEE 802.11 smart phones (Wi-Fi standard), Internet Protocol (IP) phones, personal digital assistant (PDA) for field work, notebooks used with web cameras, and remote site monitoring tablet PCs for on-site testing may be considered as wireless devices that can be used in domestic operating NPPs. Despite its advantages, wireless technology has only been used during the overhaul period in Korean NPPs due to the electromagnetic influence of sensitive equipment and cyber security problems. This paper presents the electromagnetic verification results from major sensitive equipment after using wireless devices in domestic operating NPPs. It also provides a solution for electromagnetic interference/radio frequency interference (EMI/RFI) from portable and fixed wireless devices with a Wi-Fi communication environment within domestic NPPs.

  17. Experimental results of ammonia operated condensate polishing plants in combined cycle power plants; Untersuchungsergebnisse zur Ammoniumfahrweise einer Kondensatreinigungsanlage bei GuD-Kraftwerken

    Energy Technology Data Exchange (ETDEWEB)

    Ochsmann, Christian [Erlangen-Nuernberg Univ., Erlangen (Germany); Jahr, Henrik; Glueck, Wolfgang [Siemens AG, Erlangen (Germany); Neumann, Stefan; Wedemeyer, Hans-Juergen [Lanxess Deutschland GmbH, Leverkusen (Germany)

    2013-04-01

    Modern combined cycle power plants with once-through boilers require highly pure boiler feedwater. Typically a condensate polishing plant (CPP) is used as 'salt sink' in the water-steam cycle, with a combination of cation and anion exchanger resin in a mixed bed filter. Ammonia ions are removed which reduces the lifetime of CPP. An alternative is the so-called 'ammonium form operation' which is being presented and discussed. This mode was investigated. The experimental results show that the 'ammonium form operation' is an attractive technology, which offers reduced operating costs and therefore meets economical expectations of power plant operators. (orig.)

  18. Radioactive airborne effluents and the environmental impact assessment of CAP1400 nuclear power plant under normal operation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qiong; Guo, RuiPing; Zhang, ChunMing; Chen, XiaoQiu; Wang, Bo, E-mail: wangbo@chinansc.cn

    2014-12-15

    Highlights: • Typical radionuclides dispersion from CAP1400 under normal operation was simulated. • Modified Gaussian model considered radioactive decay, dry and wet deposition and so on. • The radioactive impact pathways on the public through atmosphere were compared. • The maximum individual effective dose was lower than the public irradiation limit. - Abstract: China Advanced Passive nuclear power plant with installed capacity reaching to 1400 MW (CAP1400) is independently designed as the China's state-of-the-art third generation nuclear power brand based on AP1000 technology digestion and absorption. The concentration of typical radionuclides dispersed from CAP1400 under normal operation was calculated with modified Gaussian model, considering mixed layer height, dry deposition, wet deposition, radioactive decay and so on. The atmospheric dispersion factors, ground deposition rate, individual dose and public dose were also investigated to estimate the radioactive effects of CAP1400 under normal operation on surrounding environment and human beings. The radioactive impact pathways on the public through atmosphere, such as immersion irradiation in the smoke plume, internal irradiation from ingestion and inhalation and external irradiation from surface deposition were briefly introduced with focus on the comparison of the maximum individual effective dose to different group from atmospheric dispersion. All computation results show that the maximum individual irradiation dose happened to children with total effective irradiation dose of 4.52E−03 mSv/y, which was lower than the public irradiation limit of 0.25 mSv/y.

  19. Probabilistically Controlled Teleportation of an Arbitrary Two-Qubit State via Positive Operator-Valued Measure

    Institute of Scientific and Technical Information of China (English)

    XU Hai-Feng; HAN Lian-Fang

    2013-01-01

    We propose a tripartite scheme for probabilistically teleporting an arbitrary two-qubit state with a fourqubit duster-class state and a Bell-class state as the quantum channels.In the scheme,the sender and the controller make Bell-state measurements (BSMs) on their respective qubit pairs.With their measurement results,the receiver can reconstruct the original state probabilistically by introducing two auxiliary particles and making appropriate unitary operations and positive operator-valued measure (POVM) instead of usual projective measurement.Moreover,the total success probability and classical communication cost of the present protocol are also worked out.

  20. Thermo Vacuum State for Describing the Density Operator of Photon-subtracted Squeezed Chaotic Light

    Science.gov (United States)

    Wan, Zhi-Long; Fan, Hong-Yi; Li, Heng-Mei; Wang, Zhen

    2017-10-01

    For the density operator describing s-photon-subtracted squeezed chaotic light (PSSCL) we search for its thermo vacuum state (a pure state) in the real-fictitious space. We find that it reduces to a thermo vacuum state of squeezed chaotic light when s = 0, and to a thermo vacuum state of the optical negative binomial field when no squeezing. The new thermo vacuum state simplifies calculating photon number average, quantum fluctuation and Mandel's Q parameter of PSSCL. Using the method of integration within ordered product (IWOP) of operators we also derive the normalization coefficient and explicitly analytical expressions of Wigner function for PSSCL.

  1. Operational safety of turbine-generators at Loviisa nuclear power plant; Turbiini-generaattoreiden kaeyttoeturvallisuus Loviisan ydinvoimalaitoksella

    Energy Technology Data Exchange (ETDEWEB)

    Virolainen, T.

    1997-06-01

    The goal of the study is to assess the operational safety of the turbine-generators at the Loviisa NPP. The lay-out, operation, control, monitoring and testing of turbine-generators have been studied. Taking these findings into consideration and by using operational data of Loviisa and other power plants, the most significant safety issues of the turbine-generator system have been identified. The frequencies for initiating events and possible consequences have been determined based on plant operational experience and related literature. (58 refs.).

  2. Doubly Fed Induction Generator in an Offshore Wind Power Plant Operated at Rated V/Hz: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Singh, M.; Gevorgian, V.

    2012-06-01

    This paper introduces the concept of constant Volt/Hz operation of offshore wind power plants. The deployment of offshore WPPs requires power transmission from the plant to the load center inland. Since this power transmission requires submarine cables, there is a need to use High-Voltage Direct Current transmission, which is economical for transmission distances longer than 50 kilometers. In the concept presented here, the onshore substation is operated at 60 Hz synced with the grid, and the offshore substation is operated at variable frequency and voltage, thus allowing the WPP to be operated at constant Volt/Hz.

  3. Gravity Plant Physiology Facility (GPPF) Team in the Spacelab Payload Operations Control Center (SL

    Science.gov (United States)

    1992-01-01

    The primary payload for Space Shuttle Mission STS-42, launched January 22, 1992, was the International Microgravity Laboratory-1 (IML-1), a pressurized manned Spacelab module. The goal of IML-1 was to explore in depth the complex effects of weightlessness of living organisms and materials processing. Around-the-clock research was performed on the human nervous system's adaptation to low gravity and effects of microgravity on other life forms such as shrimp eggs, lentil seedlings, fruit fly eggs, and bacteria. Materials processing experiments were also conducted, including crystal growth from a variety of substances such as enzymes, mercury iodide, and a virus. The Huntsville Operations Support Center (HOSC) Spacelab Payload Operations Control Center (SL POCC) at the Marshall Space Flight Center (MSFC) was the air/ground communication channel used between the astronauts and ground control teams during the Spacelab missions. Featured is the Gravity Plant Physiology Facility (GPPF) team in the SL POCC during the IML-1 mission.

  4. Gravity Plant Physiology Facility (GPPF) Team in the Spacelab Payload Operations Control Center (SL

    Science.gov (United States)

    1992-01-01

    The primary payload for Space Shuttle Mission STS-42, launched January 22, 1992, was the International Microgravity Laboratory-1 (IML-1), a pressurized manned Spacelab module. The goal of IML-1 was to explore in depth the complex effects of weightlessness of living organisms and materials processing. Around-the-clock research was performed on the human nervous system's adaptation to low gravity and effects of microgravity on other life forms such as shrimp eggs, lentil seedlings, fruit fly eggs, and bacteria. Materials processing experiments were also conducted, including crystal growth from a variety of substances such as enzymes, mercury iodide, and a virus. The Huntsville Operations Support Center (HOSC) Spacelab Payload Operations Control Center (SL POCC) at the Marshall Space Flight Center (MSFC) was the air/ground communication channel used between the astronauts and ground control teams during the Spacelab missions. Featured is the Gravity Plant Physiology Facility (GPPF) team in the SL POCC during the IML-1 mission.

  5. 12 CFR 550.130 - How may I conduct multi-state operations?

    Science.gov (United States)

    2010-01-01

    ... a fiduciary for relationships that include property located in other States, and may act as a... FIDUCIARY POWERS OF SAVINGS ASSOCIATIONS Exercising Fiduciary Powers § 550.130 How may I conduct multi-state operations? (a) Conducting fiduciary activities in more than one State. You may conduct fiduciary activities...

  6. Plants teratogenic to livestock in the United States

    Science.gov (United States)

    Teratology, as a scientific discipline, is relatively new and recognition of poisonous plants that cause birth defects in livestock only came to the forefront in the 1950’s and 1960’s. The Veratrum-induced “monkey faced” lamb syndrome and lupine-induced “crooked calf disease”, both studied extensive...

  7. State of Washington, Aquatic Plant Management Program: Design Memorandum.

    Science.gov (United States)

    1979-10-01

    those on others who dil not receive it (G. K. Zemansky , our mailing list for the Aqtrt ic Plant Maa nagmenr Friends of the Earth). Study. This includes...added to the Mai ling list. Precisely what was the purpose of this survey? The purpose of the questionnaire was to provide a (G. M. Zemansky , Friends of

  8. Synthane Pilot Plant, Bruceton, Pa. Run report No. 1. Operating period: July--December 1976

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    Test Directive No. 1 provided the operating conditions and process requirements for the first coal to be gasified in the Synthane Pilot Plant. Rosebud coal, which is a western sub-bituminous coal, was chosen by DOE because of its non-caking properties and reactivity. This report summarizes and presents the data obtained. The pilot plant produced gas for a total of 228 hours and gasified 709 tons of Rosebud coal from July 7 to December 20, 1976. Most of this period was spent in achieving process reliability and learning how to operate and control the gasifier. A significant number of equipment and process changes were required to achieve successful operation of the coal grinding and handling facilities, the Petrocarb feed system, and the char handling facilities. A complete revision of all gasifier instrumentation was necessary to achieve good control. Twenty-one test runs were accomplished, the longest of which was 37 hours. During this run, carbon conversions of 57 to 60% were achieved at bed temperatures of 1450 to 1475/sup 0/F. Earlier attempts to operate the gasifier with bed temperatures of 1550 and 1650/sup 0/F resulted in clinker formation in the gasifier and the inability to remove char. Test Directive No. 1 was discontinued in January 1977, without meeting the directive's goals because the process conditions of free fall of coal feed into the Synthane gasifier resulted in excessive quantities of tar and fines carryover into the gas scrubbing area. Each time the gasifier was opened after a run, the internal cyclone dip leg was found to be plugged solidly with hard tar and fines. The gas scrubbing equipment was always badly fouled with char and tar requiring an extensive and difficult cleanout. Packing in the gas scrubber had to be completely changed twice due to extensive fouling.

  9. A Review of Traditional Medicinal Plants from Kachin State, Northern Myanmar.

    Science.gov (United States)

    Aung, Hain Thanda; Sein, Myint Myint; Aye, Mya Mu; Thu, Zaw Min

    2016-03-01

    Medicinal plants are a vital source of medication in developing countries. In Kachin State, Northern Myanmar, the people have a long history of the use of traditional plants for medicinal purposes. This article deals with the 25 most used medicinal plants in Kachin State. They are: Drynariafortunei, Tetrastigma serrulatum, Bauhinia championii, Goniothalamus cheliensis, Juglans regia, Houttuynia cordata, Osmanthus fragrans, Pothos chinensis, Tabemaemontana coronaria, Eryngiumfoetidum, Chloranthus spicatus, Peperomia pellucida, Zanthoxylum armatum, Polygonumfagopyrum, Cymbidiumfloribundum, Amomum kravanh, Coscinium fenestratum, Solanum nigrum, Gnetum parvifolium, Desmodium triquetum, Begonia augustinec, Mappianthus iodoides, Erycibe obtusifolia, Schefflera venulosa, Holarrhena antidysenterica. The different traditional applications, the known chemical constituents and medicinal properties are reported for each plant. The efficacy of several of these plants has been supported by some scientific evidence, while other plants have to be submitted to further investigations to prove the beneficial medicinal properties attributed to them.

  10. Smart Operation of Gas Turbine Combined Cycle Plants: Prediction and Improvement of Thermal Efficiency at Part Load

    NARCIS (Netherlands)

    Boksteen, S.Z.

    2014-01-01

    This thesis investigates various operational aspects of Gas Turbine Combined Cycle Power Plants (GTCC). GTCC power plants are expected to play an increasingly important role in the balancing of supply and demand in the electricity grid. Although originally meant for predominantly base load operatio

  11. Water-gas shift (WGS) Operation of Pre-combustion CO2 Capture Pilot Plant at the Buggenum IGCC

    NARCIS (Netherlands)

    Van Dijk, H.A.J.; Damen, K.; Makkee, M.; Trapp, C.

    2014-01-01

    In the Nuon/Vattenfall CO2 Catch-up project, a pre-combustion CO2 capture pilot plant was built and operated at the Buggenum IGCC power plant, the Netherlands. The pilot consist of sweet water-gas shift, physical CO2 absorption and CO2 compression. The technology performance was verified and validat

  12. Smart Operation of Gas Turbine Combined Cycle Plants: Prediction and Improvement of Thermal Efficiency at Part Load

    NARCIS (Netherlands)

    Boksteen, S.Z.

    2014-01-01

    This thesis investigates various operational aspects of Gas Turbine Combined Cycle Power Plants (GTCC). GTCC power plants are expected to play an increasingly important role in the balancing of supply and demand in the electricity grid. Although originally meant for predominantly base load

  13. Experience gained from operation of the reverse-osmosis plant at the Novosibirsk TETs-2 cogeneration station

    Science.gov (United States)

    Abramova, I. A.; Chernov, S. A.; Maikov, V. M.; Doineko, O. A.; Ustinov, B. V.; Vil'Ms, E. V.

    2008-05-01

    We present the main indicators characterizing the performance of the demineralizing plant comprising reverse-osmosis and ion-exchange equipment that produces makeup water for the boilers at the Novosibirsk TETs-2 cogeneration station for three years of plant operation.

  14. Smart Operation of Gas Turbine Combined Cycle Plants: Prediction and Improvement of Thermal Efficiency at Part Load

    NARCIS (Netherlands)

    Boksteen, S.Z.

    2014-01-01

    This thesis investigates various operational aspects of Gas Turbine Combined Cycle Power Plants (GTCC). GTCC power plants are expected to play an increasingly important role in the balancing of supply and demand in the electricity grid. Although originally meant for predominantly base load operatio

  15. Water-gas shift (WGS) Operation of Pre-combustion CO2 Capture Pilot Plant at the Buggenum IGCC

    NARCIS (Netherlands)

    Van Dijk, H.A.J.; Damen, K.; Makkee, M.; Trapp, C.

    2014-01-01

    In the Nuon/Vattenfall CO2 Catch-up project, a pre-combustion CO2 capture pilot plant was built and operated at the Buggenum IGCC power plant, the Netherlands. The pilot consist of sweet water-gas shift, physical CO2 absorption and CO2 compression. The technology performance was verified and

  16. Water-gas shift (WGS) Operation of Pre-combustion CO2 Capture Pilot Plant at the Buggenum IGCC

    NARCIS (Netherlands)

    Van Dijk, H.A.J.; Damen, K.; Makkee, M.; Trapp, C.

    2014-01-01

    In the Nuon/Vattenfall CO2 Catch-up project, a pre-combustion CO2 capture pilot plant was built and operated at the Buggenum IGCC power plant, the Netherlands. The pilot consist of sweet water-gas shift, physical CO2 absorption and CO2 compression. The technology performance was verified and validat

  17. 10 CFR Appendix N to Part 52 - Standardization of Nuclear Power Plant Designs: Combined Licenses To Construct and Operate...

    Science.gov (United States)

    2010-01-01

    ... Licenses To Construct and Operate Nuclear Power Reactors of Identical Design at Multiple Sites N Appendix N... FOR NUCLEAR POWER PLANTS Pt. 52, App. N Appendix N to Part 52—Standardization of Nuclear Power Plant... that the applicant wishes to have the application considered under 10 CFR part 52, appendix N, and must...

  18. A comparison between a steady state and a pulsed fusion power plant

    Energy Technology Data Exchange (ETDEWEB)

    Zollino, G., E-mail: giuseppe.zollino@igi.cnr.it [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione Corso Stati Uniti 4, 35127 Padova (Italy); Casini, G.; Pierobon, D.; Antoni, V.; Bolzonella, T.; Piovan, R. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione Corso Stati Uniti 4, 35127 Padova (Italy)

    2011-10-15

    In the paper the first results of a simplified code (FRESCO) for the evaluation of capital cost and cost of electricity of a D-T Tokamak fusion power plant are reported. For the scope of this paper, only the main assumptions and features of the code are described and its validation against the figures of the European PPCS plant models are presented. The code is here applied to compare the costs of a steady state and a pulsed fusion power plant.

  19. Inventory of power plants in the United States. [By state within standard Federal Regions, using county codes

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    The purpose of this inventory of power plants is to provide a ready reference for planners whose focus is on the state, standard Federal region, and/or national level. Thus the inventory is compiled alphabetically by state within standard Federal regions. The units are listed alphabetically within electric utility systems which in turn are listed alphabetically within states. The locations are identified to county level according to the Federal Information Processing Standards Publication Counties and County Equivalents of the States of the United States. Data compiled include existing and projected electrical generation units, jointly owned units, and projected construction units.

  20. A practical algorithm for optimal operation management of distribution network including fuel cell power plants

    Energy Technology Data Exchange (ETDEWEB)

    Niknam, Taher; Meymand, Hamed Zeinoddini; Nayeripour, Majid [Electrical and Electronic Engineering Department, Shiraz University of Technology, Shiraz (Iran)

    2010-08-15

    Fuel cell power plants (FCPPs) have been taken into a great deal of consideration in recent years. The continuing growth of the power demand together with environmental constraints is increasing interest to use FCPPs in power system. Since FCPPs are usually connected to distribution network, the effect of FCPPs on distribution network is more than other sections of power system. One of the most important issues in distribution networks is optimal operation management (OOM) which can be affected by FCPPs. This paper proposes a new approach for optimal operation management of distribution networks including FCCPs. In the article, we consider the total electrical energy losses, the total electrical energy cost and the total emission as the objective functions which should be minimized. Whereas the optimal operation in distribution networks has a nonlinear mixed integer optimization problem, the optimal solution could be obtained through an evolutionary method. We use a new evolutionary algorithm based on Fuzzy Adaptive Particle Swarm Optimization (FAPSO) to solve the optimal operation problem and compare this method with Genetic Algorithm (GA), Particle Swarm Optimization (PSO), Differential Evolution (DE), Ant Colony Optimization (ACO) and Tabu Search (TS) over two distribution test feeders. (author)

  1. [Assessment of exposure to ceramic fibers during insulation operations in a thermoelectric power plant].

    Science.gov (United States)

    Marconi, A; Cavariani, F; Carai, A; Cacchioli, G; Papandrea, F; Cacchioli, E

    2001-01-01

    Refractory ceramic fibre concentrations were measured during renewal of the insulation lining of a turbine located in a large power plant. Personal and stationary samples were collected during operations, which involved installing and ripping out standard and pre-coated and pre-shaped ceramic fibre blankets. Operation-length average (OLA) and TWA exposure levels were about 500 F/l and about 100 F/l, respectively, for installing and ripping out operations where non-coated blankets were handled. In these cases specific task-associated personal exposure levels up to 1000 F/l were measured. Personal exposure levels up to as much as 10 times lower were observed in operations involving pre-coated and pre-shaped blankets. The average concentration levels from area samples were always lower than those from personal samples, and showed a downward gradient with the distance from the source. Given the current carcinogenic classification of refractory ceramic fibres (class 2, European), the necessity is stressed of introducing adequate working practices and control measures (adoption of pre-coated and pre-shaped fibrous materials whenever possible, confinement of working area, use of local air extractions ventilation with HEPA filter unit, use of garments for personal protection and respirators, use of wetting or binding liquids prior to removal, quick cleaning of debris from working area), in order to keep the exposure levels and the number of potentially exposed workers to the minimum.

  2. Simultaneous polarization squeezing in polarized N photon state and diminution on a squeezing operation

    CERN Document Server

    Shukla, Namrata

    2016-01-01

    We study polarization squeezing of a pure photon number state which is obviously polarized but the mere change in the basis of polarization leads to simultaneous polarization squeezing in all the components of Stokes operator vector except those falling along or perpendicular to the direction of polarization state, is observed. We use the most general definition of polarization squeezing and discuss the experimental feasibility of the result. We also observe that a squeezing operation like non-degenerate parametric amplification of the state does not reveal simultaneous squeezing in all Stokes operator vectors and decreases in this sense.

  3. Proposal for the award of an industrial services contract for the operation and maintenance of liquid helium cryogenic plants

    CERN Document Server

    2000-01-01

    This document concerns the award of an Industrial Services contract for the operation and maintenance of liquid helium cryogenic plants. Following a market survey carried out among 54 firms in twelve Member States, a call for tenders (IT-2719/LHC) was sent on 18 August 2000 to two firms and four consortia, two consisting of two firms and two consisting of three firms, in five Member States. By the closing date, CERN had received tenders from one firm and three consortia, in four Member States. The Finance Committee is invited to agree to the negotiation of a contract with the consortium AIR LIQUIDE (FR) - LINDE KRYOTECHNIK (CH) - SERCO (DE), the lowest bidder, for an initial period of four years from 17 July 2001 for a total amount of 19 804 400 Swiss francs, not subject to revision until 16 July 2005. The contract will include options for two one-year extensions beyond the initial four-year period. The consortium has indicated the following distribution by country of the contract value covered by this adjudi...

  4. High-resolution solution-state NMR of unfractionated plant cell walls

    Science.gov (United States)

    John Ralph; Fachuang Lu; Hoon Kim; Dino Ress; Daniel J. Yelle; Kenneth E. Hammel; Sally A. Ralph; Bernadette Nanayakkara; Armin Wagner; Takuya Akiyama; Paul F. Schatz; Shawn D. Mansfield; Noritsugu Terashima; Wout Boerjan; Bjorn Sundberg; Mattias Hedenstrom

    2009-01-01

    Detailed structural studies on the plant cell wall have traditionally been difficult. NMR is one of the preeminent structural tools, but obtaining high-resolution solution-state spectra has typically required fractionation and isolation of components of interest. With recent methods for dissolution of, admittedly, finely divided plant cell wall material, the wall can...

  5. Water Treatment Plant Sludges--An Update of the State of the Art: Part 2.

    Science.gov (United States)

    American Water Works Association Journal, 1978

    1978-01-01

    This report outlines the state of the art with respect to nonmechanical and mechanical methods of dewatering water treatment plant sludge, ultimate solids disposal, and research and development needs. (CS)

  6. Assessment of the quality and toxicity of the discharges of a wastewater treatment plant and alternatives to improve its operation.

    Science.gov (United States)

    Robles-Vargas, Daniel; Montoya-Castillo, Sandra Margarita; Avelar-González, Francisco Javier; Jauregui-Rincón, Juan; Rodríguez-Valadez, Francisco Javier; Rico-Martínez, Roberto

    2012-01-01

    Wastewater discharges into freshwater bodies represent a serious ecological problem worldwide. In underdeveloped and developing countries wastewater treatment plants (WTP) only count with basic treatment, leading to the pollution of important aquatic reservoirs causing critical situations. In the present work, a one year evaluation of toxicity and main physical and chemical parameters of one of the major WTP of the state of Aguascalientes was conducted fortnightly, and to assess treatment alternatives for this WTP we tested: a) three white rot fungi (WRF), b) a photo-electrochemical process, c) ion-exchangers resins and activated carbon. The 3 WRF exhibited high COD removal from influents (72 - 95 %) but only Phanerochaete chrysosporium reached significant toxicity removals (70 and 55 %, for an influent and an effluent, respectively). Treatments with electrochemical advanced oxidation processes resulted with the highest toxicity and COD removals (96 % for both parameters) in comparison to biological and physicochemical treatments. Adsorption with activated carbon, zeolite and chelex ion-exchange resins removed 60 - 90 % of COD and 60 - 99 % toxicity. These results could be used to improve operation of the Industrial Park WTP and to plan future modifications to the plant.

  7. New concept for condition management of plants as a result of the KUNTO project. New operations approach reduces costs

    Energy Technology Data Exchange (ETDEWEB)

    McNiven, U.; Tamminen, L.

    1998-07-01

    IVO Generation Services Ltd. has carried out a project at the IVO Naantali power plant to develop the plants condition management. The project defines critical and monitored components for each system. In addition, recommendations for further action, investment proposals and suggestions for changes in maintenance and operations practices were supplied for the various systems in the plant. The systematic approach which was the result of the projects integrated into maintenance and operations practices where data collection and analysis is part of the routine. Up-to-date data is utilized in focusing maintenance and investments, in planning and reporting functions

  8. Standard forms and entanglement engineering of multimode Gaussian states under local operations

    Energy Technology Data Exchange (ETDEWEB)

    Serafini, Alessio [Institute for Mathematical Sciences, Imperial College London, 53 Prince' s Gate, SW7 2PG (United Kingdom); Adesso, Gerardo [Dipartimento di Fisica ' E R Caianiello' , Universita degli Studi di Salerno (Italy)

    2007-07-13

    We investigate the action of local unitary operations on multimode (pure or mixed) Gaussian states and single out the minimal number of locally invariant parameters which completely characterize the covariance matrix of such states. For pure Gaussian states, central resources for continuous-variable quantum information, we investigate separately the parameter reduction due to the additional constraint of global purity, and the one following by the local-unitary freedom. Counting arguments and insights from the phase-space Schmidt decomposition and in general from the framework of symplectic analysis, accompany our description of the standard form of pure n-mode Gaussian states. In particular, we clarify why only in pure states with n {<=} 3 modes all the direct correlations between position and momentum operators can be set to zero by local unitary operations. For any n, the emerging minimal set of parameters contains complete information about all forms of entanglement in the corresponding states. An efficient state engineering scheme (able to encode direct correlations between position and momentum operators as well) is proposed to produce entangled multimode Gaussian resources, its number of optical elements matching the minimal number of locally invariant degrees of freedom of general pure n-mode Gaussian states. Finally, we demonstrate that so-called 'block-diagonal' Gaussian states, without direct correlations between position and momentum, are systematically less entangled, on average, than arbitrary pure Gaussian states.

  9. Analyzing Density Operator in Thermal State for Complicated Time-Dependent Optical Systems

    Directory of Open Access Journals (Sweden)

    Jeong Ryeol Choi

    2014-01-01

    Full Text Available Density operator of oscillatory optical systems with time-dependent parameters is analyzed. In this case, a system is described by a time-dependent Hamiltonian. Invariant operator theory is introduced in order to describe time-varying behavior of the system. Due to the time dependence of parameters, the frequency of oscillation, so-called a modified frequency of the system, is somewhat different from the natural frequency. In general, density operator of a time-dependent optical system is represented in terms of the modified frequency. We showed how to determine density operator of complicated time-dependent optical systems in thermal state. Usually, density operator description of quantum states is more general than the one described in terms of the state vector.

  10. United States nuclear regulatory commission program for inspection of decommissioning nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Harris, P.W. [U.S. Nuclear Regulatory Commission, Washington, DC (United States)

    2001-07-01

    The United States Nuclear Regulatory Commission (USNRC or Commission) has been inspecting decommissioning commercial nuclear power plants in the United States (U.S.) since the first such facility permanently shutdown in September 1967. Decommissioning inspections have principally focused on the safe storage and maintenance of spent reactor fuel; occupational radiation exposure; environmental radiological releases; the dismantlement and decontamination of structures, systems, and components identified to contain or potentially contain licensed radioactive material; and the performance of final radiological survey of the site and remaining structures to support termination of the USNRC-issued operating license. Over the last 5 years, USNRC inspection effort in these areas has been assessed and found to provide reasonable confidence that decommissioning can be conducted safely and in accordance with Commission rules and regulations. Recently, the staff has achieved a better understanding of the risks associated with particular decommissioning accidents 1 and plans to apply these insights to amendments proposed to enhance decommissioning rules and regulations. The probabilities, scenarios, and conclusions resulting from this effort are being assessed as to their applicability to the inspection of decommissioning commercial power reactors. (author)

  11. Comparison of Standards and Technical Requirements of Grid-Connected Wind Power Plants in China and the United States

    Energy Technology Data Exchange (ETDEWEB)

    Gao, David Wenzhong [Alternative Power Innovations, LLC; Muljadi, Eduard [National Renewable Energy Lab. (NREL), Golden, CO (United States); Tian, Tian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Miller, Mackay [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wang, Weisheng [China Electric Power Research Inst. (China)

    2016-09-01

    The rapid deployment of wind power has made grid integration and operational issues focal points in industry discussions and research. Compliance with grid connection standards for wind power plants (WPPs) is crucial to ensuring the reliable and stable operation of the electric power grid. This report compares the standards for grid-connected WPPs in China to those in the United States to facilitate further improvements in wind power standards and enhance the development of wind power equipment. Detailed analyses of power quality, low-voltage ride-through capability, active power control, reactive power control, voltage control, and wind power forecasting are provided to enhance the understanding of grid codes in the two largest markets of wind power. This study compares WPP interconnection standards and technical requirements in China to those in the United States.

  12. 10 CFR Appendix N to Part 50 - Standardization of Nuclear Power Plant Designs: Permits To Construct and Licenses To Operate...

    Science.gov (United States)

    2010-01-01

    ... Construct and Licenses To Operate Nuclear Power Reactors of Identical Design at Multiple Sites N Appendix N... FACILITIES Pt. 50, App.N Appendix N to Part 50—Standardization of Nuclear Power Plant Designs: Permits To..., apply to construction permits and operating licenses subject to this appendix N. 2. Applications for...

  13. Treatment of Wastewater from Electroplating, Metal Finishing and Printed Circuit Board Manufacturing. Operation of Wastewater Treatment Plants Volume 4.

    Science.gov (United States)

    California State Univ., Sacramento. Dept. of Civil Engineering.

    One of four manuals dealing with the operation of wastewater plants, this document was designed to address the treatment of wastewater from electroplating, metal finishing, and printed circuit board manufacturing. It emphasizes how to operate and maintain facilities which neutralize acidic and basic waters; treat waters containing metals; destroy…

  14. An overview of the United States Department of Energy plant lifetime improvement program

    Energy Technology Data Exchange (ETDEWEB)

    Rosinski, S.T.; Clauss, J.M. [Sandia National Labs., Albuquerque, NM (United States); Harrison, D.L. [USDOE, Washington, DC (United States)

    1993-08-01

    Today, 109 nuclear power plants provide over 20 percent of the electrical energy generated in the US. The operating license of the first of these plants will expire in the year 2000; one third of the operating licenses will expire by 2010 and the remaining plant licenses are scheduled to expire by 2033. The National Energy Strategy assumes that 70 percent of these plants will continue to operate beyond their current license expiration to assist in ensuring an adequate, diverse, and environmentally acceptable energy supply for economic growth. In order to preserve this energy resource in the US three major tasks must be successfully completed: (1) establishment of the regulations, technical standards, and procedures for the preparation and review of a license renewal application; (2) development, verification, and validation of the various technical criteria and bases for needed monitoring, refurbishment, or replacement of plant equipment; and (3) demonstration of the regulatory process. Since 1985, the US Department of Energy (DOE) has been working with the nuclear industry and the US Nuclear Regulatory Commission (NRC) to establish and demonstrate the option to extend the life of nuclear power plants through the renewal of operating licenses. This paper focuses primarily on DOE`s Plant Lifetime Improvement (PLIM) Program efforts to develop the technical criteria and bases for effective aging management and lifetime improvement for continued operation of nuclear power plants. This paper describes current projects to resolve generic technical issues, including degradation of long-lived components, reactor pressure vessel (RPV) embrittlement management approaches, and analytical methodologies to characterize RPV integrity.

  15. State Criterion of Wind Turbine Generator in Operation with Using Tower Shadow Effect

    OpenAIRE

    2002-01-01

    Because of low cost and maintenance free, inductron machines are widely used as the wind turbine generators. In order to get wind energy effectively, pole-change-type induction generators are adopted. Otherwise, the pole-change-type induction generator causes the voltage dips at starting and at pole changing time. To keep the power quality, it is important to know the state change of the generator operation. In this paper a new state criterion of wind turbine generator in operation using the ...

  16. Advanced Control Scenario of High-Performance Steady-State Operation for JT-60 Superconducting Tokamak

    Institute of Scientific and Technical Information of China (English)

    H. Tamai; Y. Kamada; A. Sakasai; S. Ishida; G. Kurita; M. Matsukawa; K. Urata; S. Sakurai; K. Tsuchiya; A. Morioka; Y. M. Miura; K. Kizu

    2004-01-01

    Plasma control on high-βN steady-state operation for JT-60 superconducting modification is discussed. Accessibility to high-βN exceeding the free-boundary limit is investigated with the stabilising wall of reduced-activated ferritic steel and the active feedback control of the in-vessel non-axisymmetric field coils. Taking the merit of superconducting magnet, advanced plasma control for steady-state high performance operation could be expected.

  17. W-026 integrated engineering cold run operational test report for balance of plant (BOP)

    Energy Technology Data Exchange (ETDEWEB)

    Kersten, J.K.

    1998-02-24

    This Cold Run test is designed to demonstrate the functionality of systems necessary to move waste drums throughout the plant using approved procedures, and the compatibility of these systems to function as an integrated process. This test excludes all internal functions of the gloveboxes. In the interest of efficiency and support of the facility schedule, the initial revision of the test (rev 0) was limited to the following: Receipt and storage of eight overpacked drums, four LLW and four TRU; Receipt, routing, and staging of eleven empty drums to the process area where they will be used later in this test; Receipt, processing, and shipping of two verification drums (Route 9); Receipt, processing, and shipping of two verification drums (Route 1). The above listed operations were tested using the rev 0 test document, through Section 5.4.25. The document was later revised to include movement of all staged drums to and from the LLW and TRU process and RWM gloveboxes. This testing was performed using Sections 5.5 though 5.11 of the rev 1 test document. The primary focus of this test is to prove the functionality of automatic operations for all mechanical and control processes listed. When necessary, the test demonstrates manual mode operations as well. Though the gloveboxes are listed, only waste and empty drum movement to, from, and between the gloveboxes was tested.

  18. Safe Operation of Nuclear Power Plants: Impacts of Human and Organisational Factors and Emerging Technologies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    In co-operation with the OECD Nuclear Energy Agency (NEA), the Halden Reactor Project organised a Summer School on ''Safe Operation of Nuclear Power Plants: Impacts of Human and Organisational Factors and Emerging Technologies'' in the period August 27-August 31, 2001. The Summer School was intended for scientists, engineers and technicians working for nuclear installations, engineering companies, industry and members of universities and research institutes, who wanted to broaden their nuclear background by getting acquainted with Man-Technology-Organisation-related subjects and issues. The Summer School should also serve to transfer knowledge to the ''young generation'' in the nuclear field. The following presentations were given: (1) Overview of the Nuclear Community and Current issues, (2) The Elements of Safety Culture; Evaluation of Events, (3) Quality Management (QM), (4) Probabilistic Risk Assessment (PSA), (5) Human Behaviour from the Viewpoint of Industrial Psychology, (6) Technical tour of the Halden Project Experimental Facilities, (7) Human Factors in Control Room Design, (8) Computerised Operator Support Systems (COSSs) and (9) Artificial Intelligence; a new Approach. Most of the contributions are overhead figures from spoken lectures.

  19. Carbon emission impact on the operation of virtual power plant with combined heat and power system

    Institute of Scientific and Technical Information of China (English)

    Yu-hang XIA; Jun-yong LIU; Zheng-wen HUANG; Xu ZHANG

    2016-01-01

    A virtual power plant (VPP) can realize the aggregation of distributed generation in a certain region, and represent distributed generation to participate in the power market of the main grid. With the expansion of VPPs and ever-growing heat demand of consumers, managing the effect of fluctuations in the amount of available renewable resources on the operation of VPPs and maintaining an economical supply of electric power and heat energy to users have been important issues. This paper proposes the allocation of an electric boiler to realize wind power directly converted for supplying heat, which can not only overcome the limitation of heat output from a combined heat and power (CHP) unit, but also reduce carbon emissions from a VPP. After the electric boiler is considered in the VPP operation model of the combined heat and power system, a multi-objective model is built, which includes the costs of carbon emissions, total operation of the VPP and the electricity traded between the VPP and the main grid. The model is solved by the CPLEX package using the fuzzy membership function in Matlab, and a case study is pre-sented. The power output of each unit in the case study is analyzed under four scenarios. The results show that after carbon emission is taken into account, the output of low carbon units is significantly increased, and the allocation of an electric boiler can facilitate the maximum absorption of renewable energy, which also reduces carbon emissions from the VPP.

  20. Increment of the operational stability of the NGL I plant located in the Tablazo Petrochemical Complex, working with a low feed gas flow rate

    Energy Technology Data Exchange (ETDEWEB)

    Mendez, Alejandro

    2004-07-01

    The function of the plant NGL I is to extract the ethane and the liquids of the current of natural gas coming from Maracaibo Lake, emphatically in the ethane and propane for being a raw material for the olefins synthesis. The needed temperature for the condensation takes place cooling the dehydrated feed gas, by means of the heat exchange with two currents, cooling propane and the other cold methane gas. In 1998 some improvements to the plant were made, which are known as (MERE) (Ethane Recovery Improvements Project), these modifications were made in order to enhance the ethane recovery during the process, however, when it started to work under this modifications high instability in the performance of the compressor located in the refrigeration system was observed, which produced the shutdown of the ethane recovery process when working with feed gas stream flow rates (under 130 MMSCFD). Moreover, during the last years a decrease in the feed gas flow has been observed, in a mean of 120 MMSCFD, which has had a negative effect on the plant, because it has worked in a non-continuous state. Thanks to several improvements implemented in the actuality, we have achieved to diminish the minimal flow of operation of the plant to 95 MMPCSD, allowing the ethane production at this flow of feeding and increased the operational stability of the plant of LNG I. (author)

  1. Predicting working days for secondary tillage and planting operation in fall

    Directory of Open Access Journals (Sweden)

    A Kosari Moghaddam

    2016-09-01

    Full Text Available Introduction The working day is an important component in selection and analysis of farm machinery systems. The number of working days is affected by various factors such as climate, soil characteristics and type of operation. Daily soil moisture models based on weather long-term data and soil characteristics were almost used for calculating probability of working days. The goal of this study was to develop a simulation model to predict the number of working days for secondary tillage and planting operation in fall at 50, 80 and 90% probability levels. Materials and Methods A Simulation model was developed using 21 years weather data and soil characteristics for calculate daily soil moisture content in Research Station of Ferdowsi University of Mashhad. So soil moisture was calculated using daily soil water equation for top 25 centimeter of soil depth. Moisture equal or lower than 85% of soil field capacity and precipitation lower than 4 millimeter (local data were considered as soil workability criteria. Then the working days were determined for secondary tillage and planting operation at 50, 80 and 90% probability levels in falls. The number of days at 50% probability was the mean over 21 years and the number of days at 80% and 90% were determined for each two weeks period as the average number of working days minus the product of t value and standard deviation of those numbers. Model Evaluation Evaluation of model included a comparison of predicted and the observed the number of working days in Research Station of Ferdowsi University of Mashhad during 2002-2010 and sensitivity analysis was implemented to test the effect of changes in soil workability criterion (80, 90, 95 and 100% of soil field capacity, drainage coefficient (25 % decrease and increase and soil field capacity (40% increase on simulation results. Results and Discussion Comparison of predicted and observed days showed that correlation coefficient was 0.998 and the difference

  2. Two Thermoeconomic Diagnosis Methods Applied to Representative Operating Data of a Commercial Transcritical Refrigeration Plant

    Directory of Open Access Journals (Sweden)

    Torben Ommen

    2017-02-01

    Full Text Available In order to investigate options for improving the maintenance protocol of commercial refrigeration plants, two thermoeconomic diagnosis methods were evaluated on a state-of-the-art refrigeration plant. A common relative indicator was proposed for the two methods in order to directly compare the quality of malfunction identification. Both methods were applicable to locate and categorise the malfunctions when using steady state data without measurement uncertainties. By introduction of measurement uncertainty, the categorisation of malfunctions became increasingly difficult, though depending on the magnitude of the uncertainties. Two different uncertainty scenarios were evaluated, as the use of repeated measurements yields a lower magnitude of uncertainty. The two methods show similar performance in the presented study for both of the considered measurement uncertainty scenarios. However, only in the low measurement uncertainty scenario, both methods are applicable to locate the causes of the malfunctions. For both the scenarios an outlier limit was found, which determines if it was possible to reject a high relative indicator based on measurement uncertainty. For high uncertainties, the threshold value of the relative indicator was 35, whereas for low uncertainties one of the methods resulted in a threshold at 8. Additionally, the contribution of different measuring instruments to the relative indicator in two central components was analysed. It shows that the contribution was component dependent.

  3. Biofouling evaluation in the seawater cooling circuit of an operating coastal power plant

    Energy Technology Data Exchange (ETDEWEB)

    Murthy, P.S.; Veeramani, P.; Ershath, M.I.M.; Venugopalan, V.P. [BARC Facilities, Water and Steam Chemistry Div., Kalpakkam, Tamil Nadu (India)

    2010-07-01

    Chlorination is the most commonly used method of biofouling control in cooling water systems of coastal power stations. In the present study, we report results of extensive sampling in different sections of the cooling water system of an operating power station undertaken during three consecutive maintenance shutdowns. The power plant employed continuous low level chlorination (0.2 ± 0.1 mg L{sup -1} TRO) with twice-a-week booster dosing (0.4 ± 0.1 mg L-1 TRO for 8 hours). In addition, the process seawater heat exchangers received supplementary dosing of bromide treatment (0.2 ± 0.1 mg L{sup -1} TRO for 1 hour in every 8 h shift). Biofouling samples were collected from the cooling water conduits, heat exchanger water boxes, pipelines, heated discharge conduits and outfall section during the annual maintenance shutdown of the plant in the years 2007, 2008 and 2009. Simultaneous monitoring of biofouling on test coupons in coastal waters enabled direct comparison of fouling situation on test panels and that in the cooling system. The data showed significant reduction in biofouling inside the cooling circuit as compared to the coastal waters. However, significant amount of fouling was still evident at several places, indicating inadequacy of the biocide treatment regime. The maximum load of 31.3 kg m{sup 2} y{sup -1} was observed in the conduits leading to the process seawater heat exchangers (PSW-HX) and the minimum of 1.3 kg m{sup 2} y{sup -1} was observed in the outfall section. Fouling loads of 12.2 - 14.7 kg m{sup 2} y{sup -1} were observed in the concrete conduits feeding the main condensers. Bromide treatment ahead of the PSW-HX could marginally reduce the fouling load in the downstream section of the dosing point; the HX inlets still showed good biofouling. Species diversity across the cooling water system showed the pre-condenser section to be dominated by green mussels (Perna viridis), pearl oysters (Pinctada sp.) and edible oysters (Crassostrea sp

  4. A Series RCL Circuit Theory for Analyzing Non-Steady-State Water Uptake of Maize Plants

    Science.gov (United States)

    Zhuang, Jie; Yu, Gui-Rui; Nakayama, Keiichi

    2014-10-01

    Understanding water uptake and transport through the soil-plant continuum is vital for ecosystem management and agricultural water use. Plant water uptake under natural conditions is a non-steady transient flow controlled by root distribution, plant configuration, soil hydraulics, and climatic conditions. Despite significant progress in model development, a mechanistic description of transient water uptake has not been developed or remains incomplete. Here, based on advanced electrical network theory (RLC circuit theory), we developed a non-steady state biophysical model to mechanistically analyze the fluctuations of uptake rates in response to water stress. We found that the non-steady-state model captures the nature of instantaneity and hysteresis of plant water uptake due to the considerations of water storage in plant xylem and coarse roots (capacitance effect), hydraulic architecture of leaf system (inductance effect), and soil-root contact (fuse effect). The model provides insights into the important role of plant configuration and hydraulic heterogeneity in helping plants survive an adverse environment. Our tests against field data suggest that the non-steady-state model has great potential for being used to interpret the smart water strategy of plants, which is intrinsically determined by stem size, leaf size/thickness and distribution, root system architecture, and the ratio of fine-to-coarse root lengths.

  5. State dependence, personality, and plants: light-foraging decisions in Mimosa pudica (L.).

    Science.gov (United States)

    Simon, Franz W; Hodson, Christina N; Roitberg, Bernard D

    2016-09-01

    Plants make foraging decisions that are dependent on ecological conditions, such as resource availability and distribution. Despite the field of plant behavioral ecology gaining momentum, ecologists still know little about what factors impact plant behavior, especially light-foraging behavior. We made use of the behavioral reaction norm approach to investigate light foraging in a plant species that exhibits rapid movement: Mimosa pudica. We explored how herbivore avoidance behavior in M. pudica (which closes its leaflets temporarily when disturbed) is affected by an individual's energy state and the quality of the current environment and also repeatedly tested the behavior of individuals from two seed sources to determine whether individuals exhibit a "personality" (i.e., behavioral syndrome). We found that when individuals are in a low-energy state, they adopt a riskier light-foraging strategy, opening leaflets faster, and not closing leaflets as often in response to a disturbance. However, when plants are in a high-energy state, they exhibit a plastic light-foraging strategy dependent on environment quality. Although we found no evidence that individuals exhibit behavioral syndromes, we found that individuals from different seed sources consistently behave differently from each other. Our results suggest that plants are capable of making state-dependent decisions and that plant decision making is complex, depending on the interplay between internal and external factors.

  6. Transition Operators Entering Neutrinoles Double Electron Capture to Excited Nuclear States

    CERN Document Server

    Vergados, J D

    2011-01-01

    We construct the effective transition operators relevant for neutrinoless double electron capture leading to final nuclear states different than $0^{+}$. From the structure of these operators we see that, if such a process is observed experimentally, it will be very helpful in singling out the very important light neutrino mass contribution from the other lepton violating mechanisms

  7. An entanglement concentration protocol for cluster states using CNOT gate operation

    Indian Academy of Sciences (India)

    CHOUDHURY BINAYAK S; DHARA ARPAN

    2016-05-01

    The purpose of this paper is a proposal on entanglement concentration protocol forcluster states. The protocol uses CNOT gate operation and is assisted with a single qubit. Moreover, the local and non-local operations are performed by a single party. We also make a comparative numerical study of the residual entanglement left out after the execution of each step of the protocol.

  8. Conceptualising the Impact of Arousal and Affective State on Training Outcomes of Operant Conditioning

    Directory of Open Access Journals (Sweden)

    Paul D. McGreevy

    2013-04-01

    Full Text Available Animal training relies heavily on an understanding of species-specific behaviour as it integrates with operant conditioning principles. Following on from recent studies showing that affective states and arousal levels may correlate with behavioural outcomes, we explore the contribution of both affective state and arousal in behavioural responses to operant conditioning. This paper provides a framework for assessing how affective state and arousal may influence the efficacy of operant training methods. It provides a series of three-dimensional conceptual graphs as exemplars to describing putative influences of both affective state and arousal on the likelihood of dogs and horses performing commonly desired behaviours. These graphs are referred to as response landscapes, and they highlight the flexibility available for improving training efficacy and the likely need for different approaches to suit animals in different affective states and at various levels of arousal. Knowledge gaps are discussed and suggestions made for bridging them.

  9. Numerical method for determining the allowable medium temperature during transient operation of a thick-walled boiler element in power plant

    Science.gov (United States)

    Rząsa, Dariusz; Duda, Piotr

    2011-12-01

    Secure and cost-effective power generation has become very important nowdays. Care must be taken while designing and operating modern steam power plants. There are regulations such as German boiler regulations (Technische Regeln für Dampfkessel 301) or European Standards that guide the user how to operate the steam power plants. However, those regulations are based on the quasi-steady state assumption and one dimensional temperature distribution in the entire element. This simplifications may not guarantee that the heating and cooling operations are conducted in the most efficient way. Thus, it was important to find an improved method that can allow to establish optimum parameters for heating and cooling operations. The optimum parameters should guarantee that the maximum total stresses in the construction element are in the allowable limits and the entire process is conducted in the shortest time. This paper summarizes mathematical descriptions how to optimize shut down process of power block devices. The optimization formulation is based on the assumption that the maximum total stresses in the whole construction element should be kept within allowable limits during cooling operation. Additionally, the operation should be processed in the shortest time possible.

  10. [Diversity of plant in Jiaxing Shijiuyang ecological wetland for drinking water during operation].

    Science.gov (United States)

    Shen, Ya-Qiang; Wei, Hong-Bin; Cheng, Wang-Da; Zhang, Hong-Mei; Wang, Wei-Dong; Yin, Cheng-Qing

    2011-10-01

    The Shijiuyang ecological wetland for drinking water of Jiaxing City, Zhejiang Province is one of the biggest constructed wetlands for water resource protection in China. To ensure a deep understanding of the present status of the wetland vegetation of Shijiuyang ecological wetland which has been run for 2.5 years and provide support for the vegetation management of ecological wetland, systematic investigation was carried out by using plot method and quadrat method in October to November, 2010. The species composition, dynamics of plant diversity and the biomass production during operation were analyzed. Altogether 70 species belonging to 28 families and 62 genera were recorded. Among them, there were 26 wetland plants, 20 mesophytes, 14 emergent, 4 submerged, 6 floating ones. Compared with the preliminary stage, the species numbers of wetland plants increased significantly from 15 species to 70 species. The spatial pattern of riparian species diversity was examined by adopting the Simpson index and Shannon-Wiener index as species diversity indices. The results showed that the riparian species diversity was higher in the west of the Beijiaohe river (Simpson index = 0.468 3, Shannon-Wiener index = 0.835 2) than that in the south of the Dongsheng Road (Simpson index = 0.357 6, Shannon-Wiener index = 0.660 4). The analyses of quantitative characteristics of wetland vegetation showed that the plants in the root-channel purification zone in the south of the Dongsheng Road grew better than those in the west of the Beijiaohe river. With regard to the riparian vegetation, the riparian plants in the west of the Beijiaohe river were more abundant. The mean biomass production (dry weight) in the root-channel purification zone was 1.73 kg x m(-2) and the total area was 9.12 x 10(4) m2, so the total biomass production was estimated to be 157.8 t. In the same way, the mean riparian vegetation biomass production(dry weight) was 0.83 kg x m(-2) and the total vegetation area was 3

  11. Can high fields save the tokamak? The challenge of steady-state operation for low cost compact reactors

    Science.gov (United States)

    Freidberg, Jeffrey; Dogra, Akshunna; Redman, William; Cerfon, Antoine

    2016-10-01

    The development of high field, high temperature superconductors is thought to be a game changer for the development of fusion power based on the tokamak concept. We test the validity of this assertion for pilot plant scale reactors (Q 10) for two different but related missions: pulsed operation and steady-state operation. Specifically, we derive a set of analytic criteria that determines the basic design parameters of a given fusion reactor mission. As expected there are far more constraints than degrees of freedom in any given design application. However, by defining the mission of the reactor under consideration, we have been able to determine the subset of constraints that drive the design, and calculate the values for the key parameters characterizing the tokamak. Our conclusions are as follows: 1) for pulsed reactors, high field leads to more compact designs and thus cheaper reactors - high B is the way to go; 2) steady-state reactors with H-mode like transport are large, even with high fields. The steady-state constraint is hard to satisfy in compact designs - high B helps but is not enough; 3) I-mode like transport, when combined with high fields, yields relatively compact steady-state reactors - why is there not more research on this favorable transport regime?

  12. Extending simulations for virtual commissioning to operating plants. Challenges during the operation phase of industrial plants and use cases for simulations in parallel to operating plants; Von der virtuellen Inbetriebnahme zur Betriebsparallelen Simulation. Herausforderungen im Anlagenbetrieb und Nutzenpotentiale der Betriebsparallelen Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kain, Sebastian; Schiller, Frank [TU Muenchen (Germany). Lehrstuhl fuer Informationstechnik im Maschinenwesen; Heuschmann, Christian [Siemens AG, Nuernberg (Germany). Industry Sector, Industry Automation, Advanced Technologies and Standards

    2008-07-01

    Short product life cycles, increasing complexity of machines and production plants as well as competitive markets require the identification of the potential for reducing efforts concerning time and costs during the life cycle of production plants. In this context, simulation plays a key role. While simulation methods are mainly applied during the development and engineering phases nowadays, the use of simulation models in parallel to machines and industrial plants during the operation phase provides additional benefits, not entirely discovered at present. In this paper, potentials are derived in use cases and two methodological approaches based on a simulation of the plant running in parallel are presented. (orig.)

  13. Invasive alien woody plants of the Orange Free State

    Directory of Open Access Journals (Sweden)

    L. Henderson

    1991-12-01

    Full Text Available The frequency and abundance of invasive alien woody plants were recorded along roadsides and at watercourse crossings in 66% (151/230 of the quarter degree squares in the study area. The survey yielded 64 species of which the most prominent (in order of prominence in streambank habitats were:  Salix babylonica, Populus x  canescens, Acacia dealbata and  Salix fragilis (fide R.D. Meikle pers. comm . The most prominent species (in order of prominence in roadside and veld habitats were:  Opunlia ficus-indica, Prunus persica, Eucalyptus spp..  Rosa eglanteria, Pyracantha angustifolia and Acacia dealbata.Little invasion was recorded for most of the province. The greatest intensity of invasion was recorded along the perennial rivers and rocky hillsides in the moist grassland of the eastern mountain region bordering on Lesotho and Natal.

  14. Invasive alien woody plants of the Orange Free State

    Directory of Open Access Journals (Sweden)

    L. Henderson

    1991-12-01

    Full Text Available The frequency and abundance of invasive alien woody plants were recorded along roadsides and at watercourse crossings in 66% (151/230 of the quarter degree squares in the study area. The survey yielded 64 species of which the most prominent (in order of prominence in streambank habitats were:  Salix babylonica, Populus x  canescens, Acacia dealbata and  Salix fragilis (fide R.D. Meikle pers. comm . The most prominent species (in order of prominence in roadside and veld habitats were:  Opunlia ficus-indica, Prunus persica, Eucalyptus spp..  Rosa eglanteria, Pyracantha angustifolia and Acacia dealbata.Little invasion was recorded for most of the province. The greatest intensity of invasion was recorded along the perennial rivers and rocky hillsides in the moist grassland of the eastern mountain region bordering on Lesotho and Natal.

  15. The importance of flexible power plant operation for Jiangsu's wind integration

    DEFF Research Database (Denmark)

    Hong, Lixuan; Lund, Henrik; Möller, Bernd

    2012-01-01

    This paper presents the influence of different regulation strategies on wind energy integration into the existing energy system of Jiangsu. The ability of wind integration is defined in terms of the ability to avoid excess electricity production, to conserve primary energy consumption and to reduce...... regulations of Jiangsu’s energy system are compared and analyzed in the range of a wind input from 0% to 42% of the total electricity demand. It is concluded that operating power plants in a flexible way facilitates the promotion of more intermittent wind integration....... CO2 emissions in the system. Firstly, a reference model of Jiangsu’s energy system is built using the energy system analysis tool EnergyPLAN based on the year 2009. The model results are then compared to actual values from 2009 to validate their accuracy. Based on the reference model, different...

  16. Operation modes of a hydro-generator as a part of the inverter micro hydropower plant

    Science.gov (United States)

    Lukutin, B. V.; Shandarova, E. B.; Matukhin, D. L.; Makarova, A. F.; Fuks, I. L.

    2016-04-01

    The paper dwells on the selection problem of power equipment for a stand-alone inverter micro hydropower plant, in particular a hydro-generator, and evaluation of its operation modes. Numerical experiments included the modes calculation of hydroelectric units of the same type with various nominal power, supplied to the consumer according to the unchanged electric load curve. The studies developed requirements for a hydro-turbine and a synchronous generator in terms of a speed range and installed capacity, depending on the load curve. The possibility of using general industrial hydroelectric units with nominal power equal to half-maximum capacity of a typical daily load curve in rural areas was shown.

  17. The WIPP institutional program for states` involvement in WIPP transportation planning, and operations

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, R.

    1991-12-31

    The Supplemental Stipulated Agreement of 1982 between the state of New Mexico and the Department of Energy (DOE) committed the DOE to emergency response training in New Mexico. In 1988, the state of New Mexico and the DOE entered into a two-year agreement providing $203,017 for financial assistance and $67,000 for equipment to enhance the state`s emergency response capability. In 1990, this agreement was extended for an additional two years providing $226,088 for financial assistance and $39,000 for emergency response equipment. Also, in 1988 an agreement between the Western Governors` Association and the United States Department of Transportation provided $1.0 million to seven western states (Colorado, Idaho, New Mexico, Oregon, Utah, Washington, and Wyoming) to identify and implement programs to help ensure the safe transportation of transuranic waste from western points of origin to the Waste Isolation Pilot Plant (WIPP). As part of this process, the Western Governors` Association and the seven states prepared the Report to Congress, Transport of Transuranic Wastes to the Waste Isolation Pilot Plant: State Concerns and Proposed Solutions. In July 1990, a five-year cooperative agreement between the Western Governors` Association and the DOE was signed providing $1.515 million in funding to seven states along the Hanford/WIPP route. This continued the work started under the Department of Transportation`s cooperative agreement.

  18. Single-Qubit Operation Sharing with Bell and W Product States

    Institute of Scientific and Technical Information of China (English)

    JI Qi-Bin; LIU Yi-Min; LIU Xian-Song; YIN Xiao-Feng; ZHANG Zhan-Jun

    2013-01-01

    Two tripartite schemes are put forward with shared entanglements and Local Operation and Classical Communication (LOCC) for sharing an operation on a remote target sate.The first scheme uses a Bell and a symmetric W states as quantum channels,while the second replaces the symmetric W state by an asymmetric one.Both schemes are treated and compared from the aspects of quantum resource consumption,operation complexity,classical resource consumption,success probability and efficiency.It is found that the latter scheme is better than the former one.Particularly,the sharing can be achieved only probabilistically with the first scheme deterministically with the second one.

  19. 76 FR 66051 - Availability of the Fiscal Year 2010 United States Special Operations Command (USSOCOM) Inventory...

    Science.gov (United States)

    2011-10-25

    ... of the Secretary Availability of the Fiscal Year 2010 United States Special Operations Command... 2330a of Title 10 United States Code as amended by the National Defense Authorization Act for Fiscal..., Defense Procurement and Acquisition Policy, Office of Strategic Sourcing (DPAP/SS) will make available to...

  20. 77 FR 38274 - Availability of the Fiscal Year 2011 United States Special Operations Command (USSOCOM) Inventory...

    Science.gov (United States)

    2012-06-27

    ... of the Secretary Availability of the Fiscal Year 2011 United States Special Operations Command... 2330a of Title 10, United States Code as amended by the National Defense Authorization Act for Fiscal... Acquisition Policy, Office of Strategic Sourcing (DPAP/SS) will make available to the public the first...

  1. Manual of Operation for Administrative Functions, Wisconsin State University - Whitewater, 1971.

    Science.gov (United States)

    Wisconsin State Univ., Whitewater.

    This Manual of Operation for the Administrative Functions at Wisconsin State University, Whitewater was developed to more clearly identify the administrative organization at WSU and to delineate the functions of the principal administrative officers. Part I presents state statutes and procedures outlining the authority for governance at State…

  2. 75 FR 38595 - Guidance to States Regarding Driver History Record Information Security, Continuity of Operation...

    Science.gov (United States)

    2010-07-02

    ...The Federal Motor Carrier Safety Administration (FMCSA) announces guidance to State driver licensing agencies (SDLAs) to support their efforts at maintaining the security of information contained in the driver history record of commercial driver's license (CDL) holders. Further, FMCSA provides States with recommendations related to continuity of operation and disaster recovery planning to......

  3. United States Special Operations Command Strategic Issues for the Long War

    Science.gov (United States)

    2006-03-15

    for USSOCOM’s campaign plan. UNITED STATES SPECIAL OPERATIONS COMMAND STRATEGIC ISSUES FOR THE LONG WAR World order is more fundamental and primordial ... Soup to Nuts: Understanding the Elements of the Strategy The United States is a big, lumbering, pluralistic, affluent, liberal, democratic

  4. Entanglement capacity of two-qubit unitary operator for rank two mixed states

    Institute of Scientific and Technical Information of China (English)

    DI; YaoMin

    2007-01-01

    The entanglement capacity of two-qubit unitary operator acting on rank two mixed states in concurrence is discussed. The condition of perfect entangler is the same as that acting on pure states and the entanglement capacity is the mixing parameter v1. For non-perfect entangler, the upper and lower bound of the entanglement capacity are given.……

  5. Entanglement capacity of two-qubit unitary operator for rank two mixed states

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    @@ The entanglement capacity of two-qubit unitary operator acting on rank two mixed states in concurrence is discussed. The condition of perfect entangler is the same as that acting on pure states and the entanglement capacity is the mixing parameter v1. For non-perfect entangler, the upper and lower bound of the entanglement capacity are given.

  6. Potential effects of desalinated water quality on the operation stability of wastewater treatment plants.

    Science.gov (United States)

    Lew, Beni; Cochva, Malka; Lahav, Ori

    2009-03-15

    Desalinated water is expected to become the major source of drinking water in many places in the near future, and thus the major source of wastewater to arrive at wastewater treatment plants. The paper examines the effect of the alkalinity value with which the water is released from the desalination plant on the alkalinity value that would develop within the wastewater treatment process under various nitrification-denitrification operational scenarios. The main hypothesis was that the difference in the alkalinity value between tap water and domestic wastewater is almost exclusively a result of the hydrolysis of urea (NH(2)CONH(2), excreted in the human urine) to ammonia (NH(3)), regardless of the question what fraction of NH(3(aq)) is transformed to NH(4)(+). Results from a field study show that the ratio between the alkalinity added to tap water when raw wastewater is formed (in meq/l units) and the TAN (total ammonia nitrogen, mole/l) concentration in the raw wastewater is almost 1:1 in purely domestic sewage and close to 1:1 in domestic wastewater streams mixed with light industry wastewaters. Having established the relationship between TAN and total alkalinity in raw wastewater the paper examines three theoretical nitrification-denitrification treatment scenarios in the wastewater treatment plant (WWTP). The conclusion is that if low-alkalinity desalinated water constitutes the major water source arriving at the WWTP, external alkalinity will have to be added in order to avoid pH drop and maintain process stability. The results lead to the conclusion that supplying desalinated water with a high alkalinity value (e.g. > or =100 mg/l as CaCO(3)) would likely prevent the need to add costly basic chemicals in the WWTP, while, in addition, it would improve the chemical and biological stability of the drinking water in the distribution system.

  7. Clostridium cluster I and their pathogenic members in a full-scale operating biogas plant.

    Science.gov (United States)

    Dohrmann, Anja B; Walz, Meike; Löwen, Achim; Tebbe, Christoph C

    2015-04-01

    A biogas production plant operating with main and secondary digesters (MD, SD) was analysed for the diversity of bacteria from Clostridium cluster I and its pathogenic members. The plant was run in two parallel lines, both receiving silages, and one, in addition, cattle manure (CM). Quantitative PCR of 16S rRNA genes from directly extracted DNA indicated that cluster I represented 0.2 to 5.6 % of the total bacterial communities. Its prevalence was particularly low in CM and also in SD compared to MD, indicating its decline during fermentation. In contrast, another highly abundant clostridial group, i.e. the "faecal" cluster XIVa, remained quantitatively unaffected during fermentation. A total of 85.1 % of 581,934 rRNA gene sequences gathered by group-specific PCR from the silages, CM and digesters could be assigned to cluster I. All remaining sequences fell into other clostridial groups. The three most dominant operational taxonomic units (OTUs) introduced with CM were from cluster I, and they declined during fermentation. Fermentation with CM significantly increased OTUs of clostridia outside of cluster I but not within. The only OTUs related to pathogens were detected for Clostridium botulinum with 0.18 % of all cluster I sequences in maize silage and less than 0.01 % in the other substrates and digester materials. These OTUs could be assigned to all four established C. botulinum groups, thus, potentially covering all seven neurotoxins. Mouse lethality tests of samples with suspected presence of C. botulinum, however, indicated no toxigenic potential and, thus, no risk associated with the rare occurrence of these OTUs.

  8. A multi-agent system-based reference governor for multiobjective power plant operation

    Energy Technology Data Exchange (ETDEWEB)

    Heo, J.S.; Lee, K.Y. [Pennsylvania State Univ., University Park, PA (United States). Dept. of Electrical Engineering

    2006-07-01

    Power plants are becoming more complex as the demand for power increases. It is no longer the best solution to manage a large-scale power system by using only strictly centralized or loosely decentralized schemes. The data processing and operational requirements of large-scale systems have become excessive, especially for optimal operation. It is also challenging to generate power while minimizing the load tracking error, fuel consumption, heat loss rate and pollutant emission, and maximizing the service life of equipment. There is growing interest in the multi-agent system (MAS) to deal with problems in power systems. Each agent system has special functions to solve distribution problems. In addition, agents in an MAS can work together to solve problems, which are beyond the capabilities or knowledge of an individual agent. This paper presented an MAS-based reference governor (MAS-RG) methodology, to realize the optimal mapping between set-points and varying unit load demand by searching for the best solution to the multiobjective optimization problem. The set-points considered were for the main steam pressure and reheater/superheater steam temperatures in a 600 MW oil-fired drum-type boiler power unit. The optimal set-points were determined by solving the multiobjective optimization problem with conflicting requirements such as load following, fuel conservation, life extension of equipment, and reducing pollution. Simulation results were presented in order to demonstrate the feasibility of the proposed approach. It was concluded that the MAS-RG methodology performed well in a large-scale distributed power plant. 20 refs., 12 figs.

  9. Effects Influencing Plutonium-Absorber Interactions and Distributions in Routine and Upset Waste Treatment Plant Operations

    Energy Technology Data Exchange (ETDEWEB)

    Delegard, Calvin H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sinkov, Sergey I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fiskum, Sandra K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-05-01

    This report is the third in a series of analyses written in support of a plan to revise the Hanford Waste Treatment and Immobilization Plant (WTP) Preliminary Criticality Safety Evaluation Report (CSER) that is being implemented at the request of the U.S. Department of Energy (DOE) Criticality Safety Group. A report on the chemical disposition of plutonium in Hanford tank wastes was prepared as Phase 1 of this plan (Delegard and Jones 2015). Phase 2 is the provision of a chemistry report to describe the potential impacts on criticality safety of waste processing operations within the WTP (Freer 2014). In accordance with the request from the Environmental and Nuclear Safety Department of the WTP (Miles and Losey 2012), the Phase 2 report assessed the potential for WTP process conditions within and outside the range of normal control parameters to change the ratio of fissile material to neutron-absorbing material in the waste as it is processed with an eye towards potential implications for criticality safety. The Phase 2 study also considered the implications should WTP processes take place within the credible range of chemistry upset conditions. In the present Phase 3 report, the 28 phenomena described in the Phase 2 report were considered with respect to the disposition of plutonium and various absorber elements. The phenomena identified in the Phase 2 report are evaluated in light of the Phase 1 report and other resources to determine the impacts these phenomena might have to alter the plutonium/absorber dispositions and ratios. The outcomes of the Phase 3 evaluations then can be used to inform subsequent engineering decisions and provide reasonable paths forward to mitigate or overcome real or potential criticality concern in plant operations.

  10. Next Generation Nuclear Plant Project Evaluation of Siting a HTGR Co-generation Plant on an Operating Commercial Nuclear Power Plant Site

    Energy Technology Data Exchange (ETDEWEB)

    L.E. Demick

    2011-10-01

    This paper summarizes an evaluation by the Idaho National Laboratory (INL) Next Generation Nuclear Plant (NGNP) Project of siting a High Temperature Gas-cooled Reactor (HTGR) plant on an existing nuclear plant site that is located in an area of significant industrial activity. This is a co-generation application in which the HTGR Plant will be supplying steam and electricity to one or more of the nearby industrial plants.

  11. Operation of milling-cutter crushers in the Sukhodol'sk coal preparation plant

    Energy Technology Data Exchange (ETDEWEB)

    Lesikov, A.V.

    1984-04-01

    The Sukhodol'sk coal preparation plant, constructed in 1962 in the Donbass, and with a capacity 4,900 t/d, is equipped with 2 railroad car tippler systems. Coal is supplied in MPS cars. In winter, coal fines supplied to the plant freeze and form large blocks which do not pass through screens separating tipplers from coal hoppers. Breaking up coal blocks is time consuming. From 6 to 18 workers cut coal each day in winter. The Voroshilovgradugleobogashchenie developed the DFM-2 milling cutter for breaking up coal blocks in 1980. In 1982 the system was modified. The cutting drum which consists of 23 discs has a diameter of 750 mm and is 3850 mm wide, revolution rate is 245 rpm. The system is driven by AO2-92-6 and AO2-52-6 electric motors with a rated power of 7.5 kW. The complete milling cutter system consists of 2 units of DFM-2 cutters. The DFM-2 weighs 10.64 t, is 2.3 m long, 3.83 m wide and 1.28 m high. Cutting frozen coal blocks unloaded from a railroad car by means of the DFM-2 system does not take more than 1.5 min. Use of the system eliminates manual operations.

  12. Disturbance and climate change in United States/Mexico borderland plant communities: a state-of-the-knowledge review

    Science.gov (United States)

    Guy R. McPherson; Jake F. Weltzin

    2000-01-01

    This review evaluates the effects and importance of disturbance and climate change on plant community dynamics in the United States/Mexico borderlands region. Our primary focus is on knowledge of physiognomic-level change in grasslands and woodlands of southeastern Arizona and southwestern New Mexico. Changes in vegetation physiognomy have broad implications for...

  13. Characterization of ground state entanglement by single-qubit operations and excitation energies

    CERN Document Server

    Giampaolo, S M; Illuminati, F; Verrucchi, P; Giampaolo, Salvatore M.; Illuminati, Fabrizio; Siena, Silvio De; Verrucchi, Paola

    2006-01-01

    We consider single-qubit unitary operations and study the associated excitation energies above the ground state of interacting quantum spins. We prove that there exists a unique operation such that the vanishing of the corresponding excitation energy determines a necessary and sufficient condition for the separability of the ground state. We show that the energy difference associated to factorization exhibits a monotonic behavior with the one-tangle and the entropy of entanglement, including non analiticity at quantum critical points. The single-qubit excitation energy thus provides an independent, directly observable characterization of ground state entanglement, and a simple relation connecting two universal physical resources, energy and nonlocal quantum correlations.

  14. Modelling leaf, plant and stand flammability for ecological and operational decision making

    Science.gov (United States)

    Zylstra, Philip

    2014-05-01

    Numerous factors have been found to affect the flammability of individual leaves and plant parts; however the way in which these factors relate to whole plant flammability, fire behaviour and the overall risk imposed by fire is not straightforward. Similarly, although the structure of plant communities is known to affect the flammability of the stand, a quantified, broadly applicable link has proven difficult to establish and validate. These knowledge gaps have presented major obstacles to the integration into fire behaviour science of research into factors affecting plant flammability, physiology, species succession and structural change, so that the management of ecosystems for fire risk is largely uninformed by these fields. The Forest Flammability Model (Zylstra, 2011) is a process-driven, complex systems model developed specifically to address this disconnect. Flame dimensions and position are calculated as properties emerging from the capacity for convective heat to propagate flame between horizontally and vertically separated leaves, branches, plants and plant strata, and this capacity is determined dynamically from the ignitability, combustibility and sustainability of those objects, their spatial arrangement and a vector-based model of the plume temperature from each burning fuel. All flammability properties as well as the physics of flame dimensions, angle and temperature distributions and the vertical structure of wind within the plant array use published sub-models which can be replaced as further work is developed. This modular structure provides a platform for the immediate application of new work on any aspect of leaf flammability or fire physics. Initial validation of the model examined its qualitative predictions for trends in forest flammability as a function of time since fire. The positive feedback predicted for the subalpine forest examined constituted a 'risky prediction' by running counter to the expectations of the existing approach, however

  15. Survey of fish impingement at power plants in the United States. Volume I. The Great Lakes

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Rajendra K.; Freeman, III, Richard F.

    1977-03-01

    Impingement of fish at cooling-water intakes of 20 power plants located on the Great Lakes has been surveyed and data are presented. Descriptions of site, plant, and intake design and operation are provided. Reports in this volume summarize impingement data for individual plants in tabular and histogram formats. Information was available from differing sources such as the utilities themselves, public documents, regulatory agencies, and others. Thus, the extent of detail in the reports varies greatly from plant to plant. Histogram preparation involved an extrapolation procedure that has inadequacies. The reader is cautioned in the use of information presented in this volume to determine intake-design acceptability or intensity of impacts on ecosystems. No conclusions are presented herein; data comparisons are made in Volume IV.

  16. Survey of fish impingement at power plants in the United States. Volume II. Inland waters

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, III, Richard F.; Sharma, Rajendra K.

    1977-03-01

    Impingement of fish at cooling-water intakes of 33 power plants located on inland waters other than the Great Lakes has been surveyed and data are presented. Descriptions of site, plant, and intake design and operation are provided. Reports in this volume summarize impingement data for individual plants in tabular and histogram formats. Information was available from differing sources such as the utilities themselves, public documents, regulatory agencies, and others. Thus, the extent of detail in the reports varies greatly from plant to plant. Histogram preparation involved an extrapolation procedure that has inadequacies. The reader is cautioned in the use of information presented in this volume to determine intake-design acceptability or intensity of impacts on ecosystems. No conclusions are presented herein; data comparisons are made in Volume IV.

  17. Methods for estimating water consumption for thermoelectric power plants in the United States

    Science.gov (United States)

    Diehl, Timothy H.; Harris, Melissa; Murphy, Jennifer C.; Hutson, Susan S.; Ladd, David E.

    2013-01-01

    Water consumption at thermoelectric power plants represents a small but substantial share of total water consumption in the U.S. However, currently available thermoelectric water consumption data are inconsistent and incomplete, and coefficients used to estimate consumption are contradictory. The U.S. Geological Survey (USGS) has resumed the estimation of thermoelectric water consumption, last done in 1995, based on the use of linked heat and water budgets to complement reported water consumption. This report presents the methods used to estimate freshwater consumption at a study set of 1,284 power plants based on 2010 plant characteristics and operations data.

  18. Investigation of the impact of main control room digitalization on operators cognitive reliability in nuclear power plants.

    Science.gov (United States)

    Zhou, Yong; Mu, Haiying; Jiang, Jianjun; Zhang, Li

    2012-01-01

    Currently, there is a trend in nuclear power plants (NPPs) toward introducing digital and computer technologies into main control rooms (MCRs). Safe generation of electric power in NPPs requires reliable performance of cognitive tasks such as fault detection, diagnosis, and response planning. The digitalization of MCRs has dramatically changed the whole operating environment, and the ways operators interact with the plant systems. If the design and implementation of the digital technology is incompatible with operators' cognitive characteristics, it may have negative effects on operators' cognitive reliability. Firstly, on the basis of three essential prerequisites for successful cognitive tasks, a causal model is constructed to reveal the typical human performance issues arising from digitalization. The cognitive mechanisms which they impact cognitive reliability are analyzed in detail. Then, Bayesian inference is used to quantify and prioritize the influences of these factors. It suggests that interface management and unbalanced workload distribution have more significant impacts on operators' cognitive reliability.

  19. Thermal analysis of a solar pond power plant operated with a direct contact boiler

    Science.gov (United States)

    Sonn, A.; Letan, R.

    1981-11-01

    A solar pond power plant operated with a direct contact boiler was thermally analyzed. A binary cycle system of concentrated brine, and an organic working fluid were considered. Brine temperature of 80 C, condensation at 30 C, a 75 percent efficient turbine, and 70 percent efficient pumps were specified for the analysis. The current study involved six working fluids: butane, pentane, hexane, and freons R113, R114, R12. Each of these fluids exhibited a maximum efficiency of the system at characteristic operating conditions of the boiler. The system efficiency increased as the boiler pressure approached that of the pond. Net electrical outputs of 7-9 percent of the heat inputs were obtained for the low pressure fluids, such as pentane, hexane, and R113. Gravity flow of brine to boiler increased these values to 8-11 percent. Solute losses in brine by direct contact in boiler were estimated for pentane, as 125 kg per year per sq km of pond, or 63 kg/MWe-year. Similar orders of magnitude are obtained for the other fluids.

  20. SEMI-BATCH OPERATED CONSTRUCTED WETLANDS PLANTED WITH PHRAGMITES AUSTRALIS FOR TREATMENT OF DYEING WASTEWATER

    Directory of Open Access Journals (Sweden)

    SOON-AN ONG

    2011-10-01

    Full Text Available The objective of present study is to evaluate the using of constructed wetland under semi-batch operation for the treatment of azo dye Acid Orange 7 (AO7 containing wastewater. The emergent plant selected in our study was Phragmites australis. Toxic signs were observed at the Phragmites australis after the addition of AO7 into the wetland reactors but it can adapt to the wastewater as shown in the increase of stem as the operation continue. Our result shows that the artificial aeration and the presence of Phragmites australis had a significant impact on the removal of organic matters, AO7, aromatic amines and NH4-N. The COD removal efficiency in the aerated and non-aerated wetland reactors was 95 and 62%, respectively. The NH4-N removal efficiency in the aerated wetland reactor (86% was significantly higher than the non-aerated wetland reactor (14 %. All wetland reactors show high removal efficiency of AO7 (> 94% but only the aerated wetland reactor perform better in the removal of aromatic amines.