WorldWideScience

Sample records for planning station clamps

  1. Automating Space Station operations planning

    Science.gov (United States)

    Ziemer, Kathleen A.

    1989-01-01

    The development and implementation of the operations planning processes for the Space Station are discussed. A three level planning process, consisting of strategic, tactical, and execution level planning, is being developed. The integration of the planning procedures into a tactical planning system is examined and the planning phases are illustrated.

  2. A distributed planning concept for Space Station payload operations

    Science.gov (United States)

    Hagopian, Jeff; Maxwell, Theresa; Reed, Tracey

    1994-01-01

    The complex and diverse nature of the payload operations to be performed on the Space Station requires a robust and flexible planning approach. The planning approach for Space Station payload operations must support the phased development of the Space Station, as well as the geographically distributed users of the Space Station. To date, the planning approach for manned operations in space has been one of centralized planning to the n-th degree of detail. This approach, while valid for short duration flights, incurs high operations costs and is not conducive to long duration Space Station operations. The Space Station payload operations planning concept must reduce operations costs, accommodate phased station development, support distributed users, and provide flexibility. One way to meet these objectives is to distribute the planning functions across a hierarchy of payload planning organizations based on their particular needs and expertise. This paper presents a planning concept which satisfies all phases of the development of the Space Station (manned Shuttle flights, unmanned Station operations, and permanent manned operations), and the migration from centralized to distributed planning functions. Identified in this paper are the payload planning functions which can be distributed and the process by which these functions are performed.

  3. Nuclear Station Facilities Improvement Planning

    International Nuclear Information System (INIS)

    Hooks, R. W.; Lunardini, A. L.; Zaben, O.

    1991-01-01

    An effective facilities improvement program will include a plan for the temporary relocation of personnel during the construction of an adjoining service building addition. Since the smooth continuation of plant operation is of paramount importance, the phasing plan is established to minimize the disruptions in day-to-day station operation and administration. This plan should consider the final occupancy arrangements and the transition to the new structure; for example, computer hookup and phase-in should be considered. The nuclear industry is placing more emphasis on safety and reliability of nuclear power plants. In order to do this, more emphasis is placed on operations and maintenance. This results in increased size of managerial, technical and maintenance staffs. This in turn requires improved office and service facilities. The facilities that require improvement may include training areas, rad waste processing and storage facilities, and maintenance facilities. This paper discusses an approach for developing an effective program to plan and implement these projects. These improvement projects can range in magnitude from modifying a simple system to building a new structure to allocating space for a future project. This paper addresses the planning required for the new structures with emphasis on site location, space allocation, and internal layout. Since facility planning has recently been completed by Sargent and Leyden at six U. S. nuclear stations, specific examples from some of those plants are presented. Site planning and the establishment of long-range goals are of the utmost importance when undertaking a facilities improvement program for a nuclear station. A plan that considers the total site usage will enhance the value of both the new and existing facilities. Proper planning at the beginning of the program can minimize costs and maximize the benefits of the program

  4. Clamping characteristics study on different types of clamping unit

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Zhiwei; Liu, Haichao; Xie, Pengcheng [College of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing China 100029 (China); Yang, Weimin [College of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing China 100029 (China); State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing China 100029 (China)

    2015-05-22

    Plastic products are becoming more and more widely used in aerospace, IT, digital electronics and many other fields. With the development of technology, the requirement of product precision is getting higher and higher. However, type and working performance of clamping unit play a decisive role in product precision. Clamping characteristics of different types of clamping unit are discussed in this article, which use finite element numerical analysis method through the software ABAQUS to study the clamping uniformity, and detect the clamping force repeatability precision. The result shows that compared with toggled three-platen clamping unit, clamping characteristics of internal circulation two-platen clamping unit are better, for instance, its mold cavity deformation and force that bars and mold parting surface suffered are more uniform, and its clamping uniformity and repeatability precision is also better.

  5. Is early cord clamping, delayed cord clamping or cord milking best?

    Science.gov (United States)

    Vatansever, Binay; Demirel, Gamze; Ciler Eren, Elif; Erel, Ozcan; Neselioglu, Salim; Karavar, Hande Nur; Gundogdu, Semra; Ulfer, Gozde; Bahadir, Selcen; Tastekin, Ayhan

    2018-04-01

    To compare the antioxidant status of three cord clamping procedures (early clamping, delayed clamping and milking) by analyzing the thiol-disulfide balance. This randomized controlled study enrolled 189 term infants who were divided into three groups according to the cord clamping procedure: early clamping, delayed clamping and milking. Blood samples were collected from the umbilical arteries immediately after clamping, and the thiol/disulfide homeostasis was analyzed. The native and total thiol levels were significantly (p total thiol ratio was significantly (p = .026) lower in the delayed cord clamping and milking groups compared with the early clamping groups. Early cord clamping causes the production of more disulfide bonds and lower thiol levels, indicating that oxidation reactions are increased in the early cord clamping procedure compared with the delayed cord clamping and milking procedures. The oxidant capacity is greater with early cord clamping than with delayed clamping or cord milking. Delayed cord clamping or milking are beneficial in neonatal care, and we suggest that they be performed routinely in all deliveries.

  6. Space station evolution: Planning for the future

    Science.gov (United States)

    Diaz, Alphonso V.; Askins, Barbara S.

    1987-06-01

    The need for permanently manned presence in space has been recognized by the United States and its international partners for many years. The development of this capability was delayed due to the concurrent recognition that reusable earth-to-orbit transportation was also needed and should be developed first. While the decision to go ahead with a permanently manned Space Station was on hold, requirements for the use of the Station were accumulating as ground-based research and the data from unmanned spacecraft sparked the imagination of both scientists and entrepreneurs. Thus, by the time of the Space Station implementation decision in the early 1980's, a variety of disciplines, with a variety of requirements, needed to be accommodated on one Space Station. Additional future requirements could be forecast for advanced missions that were still in the early planning stages. The logical response was the development of a multi-purpose Space Station with the ability to evolve on-orbit to new capabilities as required by user needs and national or international decisions, i.e., to build an evolutionary Space Station. Planning for evolution is conducted in parallel with the design and development of the baseline Space Station. Evolution planning is a strategic management process to facilitate change and protect future decisions. The objective is not to forecast the future, but to understand the future options and the implications of these on today's decisions. The major actions required now are: (1) the incorporation of evolution provisions (hooks and scars) in the baseline Space Station; and (2) the initiation of an evolution advanced development program.

  7. Space station evolution: Planning for the future

    Science.gov (United States)

    Diaz, Alphonso V.; Askins, Barbara S.

    1987-01-01

    The need for permanently manned presence in space has been recognized by the United States and its international partners for many years. The development of this capability was delayed due to the concurrent recognition that reusable earth-to-orbit transportation was also needed and should be developed first. While the decision to go ahead with a permanently manned Space Station was on hold, requirements for the use of the Station were accumulating as ground-based research and the data from unmanned spacecraft sparked the imagination of both scientists and entrepreneurs. Thus, by the time of the Space Station implementation decision in the early 1980's, a variety of disciplines, with a variety of requirements, needed to be accommodated on one Space Station. Additional future requirements could be forecast for advanced missions that were still in the early planning stages. The logical response was the development of a multi-purpose Space Station with the ability to evolve on-orbit to new capabilities as required by user needs and national or international decisions, i.e., to build an evolutionary Space Station. Planning for evolution is conducted in parallel with the design and development of the baseline Space Station. Evolution planning is a strategic management process to facilitate change and protect future decisions. The objective is not to forecast the future, but to understand the future options and the implications of these on today's decisions. The major actions required now are: (1) the incorporation of evolution provisions (hooks and scars) in the baseline Space Station; and (2) the initiation of an evolution advanced development program.

  8. Space Station Freedom operations planning

    Science.gov (United States)

    Accola, Anne L.; Keith, Bryant

    1989-01-01

    The Space Station Freedom program is developing an operations planning structure which assigns responsibility for planning activities to three tiers of management. The strategic level develops the policy, goals and requirements for the program over a five-year horizon. Planning at the tactical level emphasizes program integration and planning for a two-year horizon. The tactical planning process, architecture, and products have been documented and discussed with the international partners. Tactical planning includes the assignment of user and system hardware as well as significant operational events to a time increment (the period of time from the arrival of one Shuttle to the manned base to the arrival of the next). Execution-level planning emphasizes implementation, and each organization produces detailed plans, by increment, that are specific to its function.

  9. Photovoltaic panel clamp

    Science.gov (United States)

    Mittan, Margaret Birmingham [Oakland, CA; Miros, Robert H. J. [Fairfax, CA; Brown, Malcolm P [San Francisco, CA; Stancel, Robert [Loss Altos Hills, CA

    2012-06-05

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  10. Selective Arterial Clamping Versus Hilar Clamping for Minimally Invasive Partial Nephrectomy.

    Science.gov (United States)

    Yezdani, Mona; Yu, Sue-Jean; Lee, David I

    2016-05-01

    Partial nephrectomy has become an accepted treatment of cT1 renal masses as it provides improved long-term renal function compared to radical nephrectomy (Campbell et al. J Urol. 182:1271-9, 2009). Hilar clamping is utilized to help reduce bleeding and improve visibility during tumor resection. However, concern over risk of kidney injury with hilar clamping has led to new techniques to reduce length of warm ischemia time (WIT) during partial nephrectomy. These techniques have progressed over the years starting with early hilar unclamping, controlled hypotension during tumor resection, selective arterial clamping, minimal margin techniques, and off-clamp procedures. Selective arterial clamping has progressed significantly over the years. The main question is what are the exact short- and long-term renal effects from increasing clamp time. Moreover, does it make sense to perform these more time-consuming or more complex procedures if there is no long-term preservation of kidney function? More recent studies have shown no difference in renal function 6 months from surgery when selective arterial clamping or even hilar clamping is employed, although there is short-term improved decline in estimated glomerular filtration rate (eGFR) with selective clamping and off-clamp techniques (Komninos et al. BJU Int. 115:921-8, 2015; Shah et al. 117:293-9, 2015; Kallingal et al. BJU Int. doi: 10.1111/bju.13192, 2015). This paper reviews the progression of total hilar clamping to selective arterial clamping (SAC) and the possible difference its use makes on long-term renal function. SAC may be attempted based on surgeon's decision-making, but may be best used for more complex, larger, more central or hilar tumors and in patients who have renal insufficiency at baseline or a solitary kidney.

  11. Station planning and design incorporating modern power system practice

    CERN Document Server

    Martin, PC

    1991-01-01

    The planning and design of new power stations can involve complex interaction between the many engineering disciplines involved as well as environmental, planning, economical, political and social pressures. This volume aims to provide a logical review of the procedures involved in power station development. The engineering aspects are outlined in detail, with examples, showing the basis of the relationships involved together with ""non-engineering"" factors so that the engineer can draw on the information provided for specific projects. The civil engineering and building of power stations are

  12. Planning of cascade stations on the Maotiao He detailed

    Energy Technology Data Exchange (ETDEWEB)

    Guan, W

    1984-09-20

    Details of the hydroelectric power stations on the Maotiao He cascades and examples of how some problems were resolved begin with a description of the river basin survey for topographical features, hydrometeorological conditions, and geological conditions. The river characteristics survey was the basis for planning the cascade power stations and the selection of installed capacity at each station. The review also covers discharge and flood control planning based on rainfall data and the composition of flood areas. The overall development program emphasizes power generation, but also includes irrigation, industrial water supply, and tourism. 2 figures, 1 table.

  13. TEPCO plans to construct Higashidori Nuclear Power Station

    International Nuclear Information System (INIS)

    Tsuruta, Atsushi

    2008-01-01

    In 2006, TEPCO submitted to the government plans for the construction of Higashidori Nuclear Power Station. The application was filed 41 years after the project approved by the Higashidori Village Assembly. This nuclear power station will be the first new nuclear power plant constructed by TEPCO since the construction of Units No.6 and 7 at the Kashiwazaki Kariwa Nuclear Power Station 18 years ago. Higashidori Nuclear Power Station is to be constructed at a completely new site, which will become the fourth TEPCO nuclear power station. Higashidori Nuclear Power Station Unit No.1 will be TEPCO's 18th nuclear reactor. Unit No.1 will be an advanced boiling water reactor (ABWR), a reactor-type with a proven track record. It will be TEPCO's third ABWR. Alongside incorporating the latest technology, in Higashidori Nuclear Power Station Unit No.1, the most important requirement is for TEPCO to reflect in the new unit information and experience acquired from the operation of other reactors (information and experience acquired through the experience of operating TEPCO's 17 units at Fukushima Daiichi Nuclear Power Station, Fukushima Daini Nuclear Power Station and Kashiwazaki Kashiwa Nuclear Power Station in addition to information on non-conformities at nuclear power stations in Japan and around the world). Higashidori Nuclear Power Station is located in Higashidori-Village (Aomori Prefecture) and the selected site includes a rich natural environment. From an environmental perspective, we will implement the construction with due consideration for the land and sea environment, aiming to ensure that the plant can co-exist with its natural surroundings. The construction plans are currently being reviewed by the Nuclear and Industrial Safety Agency. We are committed to making progress in the project for the start of construction and subsequent commercial operation. (author)

  14. Insulated pipe clamp design

    International Nuclear Information System (INIS)

    Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

    1980-01-01

    Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. The design considerations and methods along with the development tests are presented. Special considerations to guard against adverse cracking of the insulation material, to maintain the clamp-pipe stiffness desired during a seismic event, to minimize clamp restraint on the pipe during normal pipe heatup, and to resist clamp rotation or spinning on the pipe are emphasized

  15. Use of the Satinsky clamp for hilar clamping during robotic partial nephrectomy: indications, technique, and multi-center outcomes.

    Science.gov (United States)

    Abdullah, Newaj; Rahbar, Haider; Barod, Ravi; Dalela, Deepansh; Larson, Jeff; Johnson, Michael; Mass, Alon; Zargar, Homayoun; Kaouk, Jihad; Allaf, Mohamad; Bhayani, Sam; Stifelman, Michael; Rogers, Craig

    2017-03-01

    A Satinsky clamp may be a backup option for hilar clamping during robotic partial nephrectomy (RPN) if there are challenges with application of bulldog clamps, but there are potential safety concerns. We evaluate outcomes of RPN using Satinsky vs. bulldog clamps, and provide tips for safe use of the Satinsky as a backup option. Using a multi-center database, we identified 1073 patients who underwent RPN between 2006 and 2013, and had information available about method of hilar clamping (bulldog clamp vs. Satinsky clamp). Patient baseline characteristics, tumor features, and perioperative outcomes were compared between the Satinsky and bulldog clamp groups. A Satinsky clamp was used for hilar clamping in 94 (8.8 %) RPN cases, and bulldog clamps were used in 979 (91.2 %) cases. The use of a Satinsky clamp was associated with greater operative time (198 vs. 175 min, p hilar clamping during challenging RPN cases, but requires careful technique, and was rarely necessary.

  16. Radial wedge flange clamp

    Science.gov (United States)

    Smith, Karl H.

    2002-01-01

    A radial wedge flange clamp comprising a pair of flanges each comprising a plurality of peripheral flat wedge facets having flat wedge surfaces and opposed and mating flat surfaces attached to or otherwise engaged with two elements to be joined and including a series of generally U-shaped wedge clamps each having flat wedge interior surfaces and engaging one pair of said peripheral flat wedge facets. Each of said generally U-shaped wedge clamps has in its opposing extremities apertures for the tangential insertion of bolts to apply uniform radial force to said wedge clamps when assembled about said wedge segments.

  17. The plastic instability of clamped-clamped conical thin-walled pipe reducers

    International Nuclear Information System (INIS)

    Awad, Ibrahim; Saleh, Ch.A.R.; Ragab, A.R.

    2016-01-01

    The analytical study for plastic deformation of clamped–clamped conical reducer pipe under internal pressure does not deduce a closed form expression for the pressure at plastic instability. The presented study employs finite element analysis (FEA) to estimate the internal pressure at instability for conical reducers made of different materials and having different dimensional configurations. Forty dimensional configurations, classified as medium type, and five types of materials have been included in the analysis using ABAQUS package. A correlation expression is derived by nonlinear regression to predict the instability pressure. The proposed expression is verified for other dimensional configurations out of the above used forty models and for other materials. Experiments have been conducted by pressurizing conical clamped-clamped reducers until bursting in order to verify the finite element models. Comparison of instability pressures, strains and deflections at specific points along the conical surface shows satisfactory agreement between analysis and experiments. - Highlights: • This study offers a parametric study of the plastic instability pressure of clamped-clamped conical reducers. • A closed form analytical expression for the instability pressure is derived by using nonlinear regression. • The finite element analysis is validated by conducting bursting tests.

  18. Modular space station, phase B extension. Program operations plan

    Science.gov (United States)

    1971-01-01

    An organized approach is defined for establishing the most significant requirements pertaining to mission operations, information management, and computer program design and development for the modular space station program. The operations plan pertains to the space station and experiment module program elements and to the ground elements required for mission management and mission support operations.

  19. Impact of Base Station Cooperation on Cell Planning

    Directory of Open Access Journals (Sweden)

    Ian Dexter Garcia

    2010-01-01

    Full Text Available Base station cooperation (BSC has been identified as a key radio access technology for next-generation cellular networks such as LTE-Advanced. BSC impacts cell planning, which is the methodical selection of base station (BS sites, and BS equipment configuration for cost-effective cellular networks. In this paper, the impact of BSC on cell plan parameters (coverage, traffic, handover, and cost, as well as additional cell planning steps required for BSC are discussed. Results show that BSC maximizes its gains over noncooperation (NC in a network wherein interference from cooperating BSs is the main limitation. Locations exist where NC may produce higher throughputs, therefore dynamic or semistatic switching between BSC and NC, called fractional BSC, is recommended. Because of interference from noncooperating BSs, the gains of BSC over NC are upper bounded, and diminishes at greater intersite distances because of noise. This encourages smaller cell sizes, higher transmit powers, and dynamic clustering of cooperative BSs.

  20. Insulated pipe clamp design

    International Nuclear Information System (INIS)

    Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

    1980-01-01

    Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. 5 refs

  1. Theoretical and experimental nonlinear dynamics of a clamped-clamped beam MEMS resonator

    NARCIS (Netherlands)

    Mestrom, R.M.C.; Fey, R.H.B.; Nijmeijer, H.

    2008-01-01

    Microelectromechanical resonators feature nonlineardynamic responses. A first-principles based modeling approach is proposed for a clamped-clamped beam resonator. Starting from the partial differential equation for the beam including geometric and electrostatic nonlinear effects, a reduced-order

  2. Planning and preparedness for radiological emergencies at nuclear power stations

    International Nuclear Information System (INIS)

    Thomson, R.; Muzzarelli, J.

    1996-01-01

    The Radiological Emergency Preparedness (REP) Program was created after the March 1979 accident at the Three Mile Island nuclear power station. The Federal Emergency Management Agency (FEMA) assists state and local governments in reviewing and evaluating state and local REP plans and preparedness for accidents at nuclear power plants, in partnership with the US Nuclear Regulatory Commission (NRC), which evaluates safety and emergency preparedness at the power stations themselves. Argonne National Laboratory provides support and technical assistance to FEMA in evaluating nuclear power plant emergency response exercises, radiological emergency plans, and preparedness

  3. Loading dynamics of a sliding DNA clamp.

    KAUST Repository

    Cho, Won-Ki

    2014-05-22

    Sliding DNA clamps are loaded at a ss/dsDNA junction by a clamp loader that depends on ATP binding for clamp opening. Sequential ATP hydrolysis results in closure of the clamp so that it completely encircles and diffuses on dsDNA. We followed events during loading of an E. coli β clamp in real time by using single-molecule FRET (smFRET). Three successive FRET states were retained for 0.3 s, 0.7 s, and 9 min: Hydrolysis of the first ATP molecule by the γ clamp loader resulted in closure of the clamp in 0.3 s, and after 0.7 s in the closed conformation, the clamp was released to diffuse on the dsDNA for at least 9 min. An additional single-molecule polarization study revealed that the interfacial domain of the clamp rotated in plane by approximately 8° during clamp closure. The single-molecule polarization and FRET studies thus revealed the real-time dynamics of the ATP-hydrolysis-dependent 3D conformational change of the β clamp during loading at a ss/dsDNA junction.

  4. Simple hardware implementation of voltage balancing in capacitor-clamped inverter

    Czech Academy of Sciences Publication Activity Database

    Kokeš, Petr; Semerád, Radko

    2009-01-01

    Roč. 54, č. 4 (2009), s. 325-341 ISSN 0001-7043 R&D Projects: GA MPO FT-TA4/077 Institutional research plan: CEZ:AV0Z20570509 Keywords : capacitor -clamped multilevel inverter * flying capacitor voltage balancing * pulse width modulation (PWM) Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  5. Rocky Mountain Research Station 2008-2012 National Fire Plan Investments

    Science.gov (United States)

    Erika Gallegos

    2013-01-01

    This report highlights selected accomplishments by the USDA Forest Service Rocky Mountain Research Station's Wildland Fire and Fuels Research & Development projects in support of the National Fire Plan from 2008 through 2012. These projects are examples of the broad range of knowledge and tools developed by National Fire Plan funding beginning in 2008.

  6. Pipe clamp effects on thin-walled pipe design

    International Nuclear Information System (INIS)

    Lindquist, M.R.

    1980-01-01

    Clamp induced stresses in FFTF piping are sufficiently large to require structural assessment. The basic principles and procedures used in analyzing FFTF piping at clamp support locations for compliance with ASME Code rules are given. Typical results from a three-dimensional shell finite element pipe model with clamp loads applied over the clamp/pipe contact area are shown. Analyses performed to categorize clamp induced piping loads as primary or secondary in nature are described. The ELCLAMP Computer Code, which performs analyses at clamp locations combining clamp induced stresses with stresses from overall piping system loads, is discussed. Grouping and enveloping methods to reduce the number of individual clamp locations requiring analysis are described

  7. KSC ground operations planning for Space Station

    Science.gov (United States)

    Lyon, J. R.; Revesz, W., Jr.

    1993-01-01

    At the Kennedy Space Center (KSC) in Florida, processing facilities are being built and activated to support the processing, checkout, and launch of Space Station elements. The generic capability of these facilities will be utilized to support resupply missions for payloads, life support services, and propellants for the 30-year life of the program. Special Ground Support Equipment (GSE) is being designed for Space Station hardware special handling requirements, and a Test, Checkout, and Monitoring System (TCMS) is under development to verify that the flight elements are ready for launch. The facilities and equipment used at KSC, along with the testing required to accomplish the mission, are described in detail to provide an understanding of the complexity of operations at the launch site. Assessments of hardware processing flows through KSC are being conducted to minimize the processing flow times for each hardware element. Baseline operations plans and the changes made to improve operations and reduce costs are described, recognizing that efficient ground operations are a major key to success of the Space Station.

  8. Multifrequency Excitation of a Clamped-Clamped Microbeam

    KAUST Repository

    Jaber, Nizar R.

    2016-01-20

    We present analytical and experimental investigation of an electrically actuated clamped-clamped microbeam under a twosource harmonic excitation. The first frequency is swept around the first mode of vibration where the second one is fixed. These microbeams are fabricated using polyimide as structural layer coated with nickel form top and chromium and gold layers from bottom. We demonstrate the excitation of additive and subtractive type resonance. We show that by properly tuning the frequency and the amplitude of the excitation force, the frequency bandwidth of the resonator is increased. Theoretically, we solved the eigenvalue problem for different axial forces to find the natural frequencies ratio that match the experimental values. Using Galerkin method, a reduced order model is derived to simulate the static and dynamic response of the device where using three symmetric mode shapes provided a good agreement with experimental data. © Copyright 2015 by ASME.

  9. Planning in the Continuous Operations Environment of the International Space Station

    Science.gov (United States)

    Maxwell, Theresa; Hagopian, Jeff

    1996-01-01

    The continuous operation planning approach developed for the operations planning of the International Space Station (ISS) is reported on. The approach was designed to be a robust and cost-effective method. It separates ISS planning into two planning functions: long-range planning for a fixed length planning horizon which continually moves forward as ISS operations progress, and short-range planning which takes a small segment of the long-range plan and develops a detailed operations schedule. The continuous approach is compared with the incremental approach, the short and long-range planning functions are described, and the benefits and challenges of implementing a continuous operations planning approach for the ISS are summarized.

  10. Dungeness Power Station off-site emergency plan

    International Nuclear Information System (INIS)

    1993-01-01

    This off-site Emergency Plan in the event of an accidental release of radioactivity at the Dungeness Nuclear power station sets out the necessary management and coordination processes between Nuclear Electric, operators of the site, the emergency services and relevant local authorities. The objectives promoting the aim are identified and the activities which will be undertaken to protect the public and the environment in the event of an emergency are outlined. (UK)

  11. NIMBY, CLAMP, and the location of new nuclear-related facilities: U.S. national and 11 site-specific surveys.

    Science.gov (United States)

    Greenberg, Michael R

    2009-09-01

    Public and political opposition have made finding locations for new nuclear power plants, waste management, and nuclear research and development facilities a challenge for the U.S. government and the nuclear industry. U.S. government-owned properties that already have nuclear-related activities and commercial nuclear power generating stations are logical locations. Several studies and utility applications to the Nuclear Regulatory Commission suggest that concentrating locations at major plants (CLAMP) has become an implicit siting policy. We surveyed 2,101 people who lived within 50 miles of 11 existing major nuclear sites and 600 who lived elsewhere in the United States. Thirty-four percent favored CLAMP for new nuclear power plants, 52% for waste management facilities, and 50% for new nuclear laboratories. College educated, relatively affluent male whites were the strongest CLAMP supporters. They disproportionately trusted those responsible for the facilities and were not worried about existing nuclear facilities or other local environmental issues. Notably, they were concerned about continuing coal use. Not surprisingly, CLAMP proponents tended to be familiar with their existing local nuclear site. In short, likely CLAMP sites have a large and politically powerful core group to support a CLAMP policy. The challenge to proponents of nuclear technologies will be to sustain this support and expand the base among those who clearly are less connected and receptive to new nearby sites.

  12. Operations planning for Space Station Freedom - And beyond

    Science.gov (United States)

    Gibson, Stephen S.; Martin, Thomas E.; Durham, H. J.

    1992-01-01

    The potential of automated planning and electronic execution systems for enhancing operations on board Space Station Freedom (SSF) are discussed. To exploit this potential the Operations Planning and Scheduling Subsystem is being developed at the NASA Johnson Space Center. Such systems may also make valuable contributions to the operation of resource-constrained, long-duration space habitats of the future. Points that should be considered during the design of future long-duration manned space missions are discussed. Early development of a detailed operations concept as an end-to-end mission description offers a basis for iterative design evaluation, refinement, and option comparison, particularly when used with an advanced operations planning system capable of modeling the operations and resource constraints of the proposed designs.

  13. Daya Bay Nuclear Power Station five-year business plan and operating results

    International Nuclear Information System (INIS)

    Zhang Shanming

    2000-01-01

    Guangdong Nuclear Power Joint Venture Company, Ltd. first 5-Year Business Plan (hereinafter referred to as 5-Year Business Plan) serves as guidance of both the operations and management of the company. Continuous performance improvement of the nuclear power station has been achieved through the fulfillment of goals and improvement plan defined by the 5-Year Business Plan, and through standard and systematic management. Daya Bay Nuclear Power Station (GNPS) has made great contributions to sustainable economic developments of both Guangdong and Hong Kong since its commercial operation in 1994. As of the end of 1999, the cumulative off-take electricity generated by GNPS had reached 69.9 billion kWh. Of the WANO indicators universally applied by nuclear power industry throughout the world, 6 indicators of Daya Bay performance entered the world top quartile while 9 the medium level

  14. Analysis list: Clamp [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Clamp Cell line + dm3 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clamp.1.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clam...p.5.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clam...p.10.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/colo/Clamp.Cell_line.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/colo/Cell_line.gml ...

  15. Cell-Detection Technique for Automated Patch Clamping

    Science.gov (United States)

    McDowell, Mark; Gray, Elizabeth

    2008-01-01

    A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image

  16. Multilevel-clamped multilevel converters (MLC2)

    DEFF Research Database (Denmark)

    Rodriguez, Pedro; Bellar, Maria Dias; Muñoz-Aguliar, Raúl Santiago

    2012-01-01

    clamping scheme is the ML clamping cell, which is composed of a pair of dc sources associated with one single-pole/triple-throw type of switch arrangement. The number of series-connected ML-clamping cells will set the number of levels of the synthesized waveform. By depending on the MCU arrangements......, different converter configurations can be derived, namely, the common clamping and the modular types. Both approaches can be accomplished by employing classical three-level neutral-point-clamped (NPC) technology. Thus, the overall structure of the resultant converter is kept simple, wherein the number...

  17. Analysis of the Pallet Clamping Conditions in Work Positioning

    Directory of Open Access Journals (Sweden)

    L. A. Kolesnikov

    2016-01-01

    Full Text Available Pallets of automatic transfer lines serve as the technological and work-transfer equipment. However, their design is based on the general principles of designing machine accessories. Calculation of the basic design parameters of work based on their functioning features is fairly relevant.In pallet transfer movement over work positioning there is a mismatch between axes of the basic bushing of a pallet and the clamping locks of positioning. The paper identifies the factors influencing it, and defines the conditions to ensure the trouble-free clamping lock. The circular and rhombic clamping of pallet is simultaneous. Further, a clamping load is calculated from the pallet mass (together with the work-piece and the geometric parameters of the pallet clamping.The paper reveals three movement stages of the clamping lock in a vertical plane when setting the pallet in work positioning:- a clamping lock free play till it encounters with the location bushing;- a clamping lock play length when the lead-in chamfer contacts the bushing chamfer;- a clamping lock play length over the circular surface of bushing.The study of this process has allowed us to calculate the time of pallet clamping and dynamic loads acting on the clamping lock. These calculations made it possible to calculate the required diameter of the clamping lock. The presented calculations allow a reasonable assigning the main design parameters of work positioning for the pallet automatic lines.

  18. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping improves systemic and cerebral oxygenation in preterm lambs.

    Directory of Open Access Journals (Sweden)

    Graeme R Polglase

    Full Text Available As measurement of arterial oxygen saturation (SpO2 is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known.We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs.Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2 were measured continuously in apnoeic preterm lambs (126±1 day gestation. Positive pressure ventilation was initiated either 1 prior to umbilical cord clamping, or 2 after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping.Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping.The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  19. Piezoresistive cantilever force-clamp system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung-Jin; Petzold, Bryan C.; Pruitt, Beth L. [Department of Mechanical Engineering, Stanford University, Stanford, California 94305 (United States); Goodman, Miriam B. [Department of Molecular and Cellular Physiology, Stanford University, Stanford, California 94305 (United States)

    2011-04-15

    We present a microelectromechanical device-based tool, namely, a force-clamp system that sets or ''clamps'' the scaled force and can apply designed loading profiles (e.g., constant, sinusoidal) of a desired magnitude. The system implements a piezoresistive cantilever as a force sensor and the built-in capacitive sensor of a piezoelectric actuator as a displacement sensor, such that sample indentation depth can be directly calculated from the force and displacement signals. A programmable real-time controller operating at 100 kHz feedback calculates the driving voltage of the actuator. The system has two distinct modes: a force-clamp mode that controls the force applied to a sample and a displacement-clamp mode that controls the moving distance of the actuator. We demonstrate that the system has a large dynamic range (sub-nN up to tens of {mu}N force and nm up to tens of {mu}m displacement) in both air and water, and excellent dynamic response (fast response time, <2 ms and large bandwidth, 1 Hz up to 1 kHz). In addition, the system has been specifically designed to be integrated with other instruments such as a microscope with patch-clamp electronics. We demonstrate the capabilities of the system by using it to calibrate the stiffness and sensitivity of an electrostatic actuator and to measure the mechanics of a living, freely moving Caenorhabditis elegans nematode.

  20. The cardiovascular effects of aortic clamping and unclamping

    African Journals Online (AJOL)

    aortic clamping is that afterload and blood pressure increase, and ... individually, albeit they interact with each other. The degree of ... position of the aortic clamp, the greater the increase ... the increase in preload in response to aortic clamping.

  1. CEGB nuclear power stations basic emergency plan

    International Nuclear Information System (INIS)

    1978-03-01

    The introduction states that this is a typical emergency plan for a nuclear power station employing about 500 people, having two reactors and a total electrical output of 500 Megawatts in an intensively farmed rural area. The document has the following headings: definitions ('site incident', etc); functions of the site emergency organization; conditions for taking emergency action; persons empowered to declare or cancel a site incident or an emergency; emergency actions by staff; control centres; communication; collaboration with other bodies; warnings; transport; house rules; public information centre. (U.K.)

  2. Analyzing mobile WiMAX base station deployment under different frequency planning strategies

    Science.gov (United States)

    Salman, M. K.; Ahmad, R. B.; Ali, Ziad G.; Aldhaibani, Jaafar A.; Fayadh, Rashid A.

    2015-05-01

    The frequency spectrum is a precious resource and scarce in the communication markets. Therefore, different techniques are adopted to utilize the available spectrum in deploying WiMAX base stations (BS) in cellular networks. In this paper several types of frequency planning techniques are illustrated, and a comprehensive comparative study between conventional frequency reuse of 1 (FR of 1) and fractional frequency reuse (FFR) is presented. These techniques are widely used in network deployment, because they employ universal frequency (using all the available bandwidth) in their base station installation/configuration within network system. This paper presents a network model of 19 base stations in order to be employed in the comparison of the aforesaid frequency planning techniques. Users are randomly distributed within base stations, users' resource mapping and their burst profile selection are based on the measured signal to interference plus-noise ratio (SINR). Simulation results reveal that the FFR has advantages over the conventional FR of 1 in various metrics. 98 % of downlink resources (slots) are exploited when FFR is applied, whilst it is 81 % at FR of 1. Data rate of FFR has been increased to 10.6 Mbps, while it is 7.98 Mbps at FR of 1. The spectral efficiency is better enhanced (1.072 bps/Hz) at FR of 1 than FFR (0.808 bps/Hz), since FR of 1 exploits all the Bandwidth. The subcarrier efficiency shows how many data bits that can be carried by subcarriers under different frequency planning techniques, the system can carry more data bits under FFR (2.40 bit/subcarrier) than FR of 1 (1.998 bit/subcarrier). This study confirms that FFR can perform better than conventional frequency planning (FR of 1) which made it a strong candidate for WiMAX BS deployment in cellular networks.

  3. An Analytical Planning Model to Estimate the Optimal Density of Charging Stations for Electric Vehicles.

    Directory of Open Access Journals (Sweden)

    Yongjun Ahn

    Full Text Available The charging infrastructure location problem is becoming more significant due to the extensive adoption of electric vehicles. Efficient charging station planning can solve deeply rooted problems, such as driving-range anxiety and the stagnation of new electric vehicle consumers. In the initial stage of introducing electric vehicles, the allocation of charging stations is difficult to determine due to the uncertainty of candidate sites and unidentified charging demands, which are determined by diverse variables. This paper introduces the Estimating the Required Density of EV Charging (ERDEC stations model, which is an analytical approach to estimating the optimal density of charging stations for certain urban areas, which are subsequently aggregated to city level planning. The optimal charging station's density is derived to minimize the total cost. A numerical study is conducted to obtain the correlations among the various parameters in the proposed model, such as regional parameters, technological parameters and coefficient factors. To investigate the effect of technological advances, the corresponding changes in the optimal density and total cost are also examined by various combinations of technological parameters. Daejeon city in South Korea is selected for the case study to examine the applicability of the model to real-world problems. With real taxi trajectory data, the optimal density map of charging stations is generated. These results can provide the optimal number of chargers for driving without driving-range anxiety. In the initial planning phase of installing charging infrastructure, the proposed model can be applied to a relatively extensive area to encourage the usage of electric vehicles, especially areas that lack information, such as exact candidate sites for charging stations and other data related with electric vehicles. The methods and results of this paper can serve as a planning guideline to facilitate the extensive

  4. An Analytical Planning Model to Estimate the Optimal Density of Charging Stations for Electric Vehicles.

    Science.gov (United States)

    Ahn, Yongjun; Yeo, Hwasoo

    2015-01-01

    The charging infrastructure location problem is becoming more significant due to the extensive adoption of electric vehicles. Efficient charging station planning can solve deeply rooted problems, such as driving-range anxiety and the stagnation of new electric vehicle consumers. In the initial stage of introducing electric vehicles, the allocation of charging stations is difficult to determine due to the uncertainty of candidate sites and unidentified charging demands, which are determined by diverse variables. This paper introduces the Estimating the Required Density of EV Charging (ERDEC) stations model, which is an analytical approach to estimating the optimal density of charging stations for certain urban areas, which are subsequently aggregated to city level planning. The optimal charging station's density is derived to minimize the total cost. A numerical study is conducted to obtain the correlations among the various parameters in the proposed model, such as regional parameters, technological parameters and coefficient factors. To investigate the effect of technological advances, the corresponding changes in the optimal density and total cost are also examined by various combinations of technological parameters. Daejeon city in South Korea is selected for the case study to examine the applicability of the model to real-world problems. With real taxi trajectory data, the optimal density map of charging stations is generated. These results can provide the optimal number of chargers for driving without driving-range anxiety. In the initial planning phase of installing charging infrastructure, the proposed model can be applied to a relatively extensive area to encourage the usage of electric vehicles, especially areas that lack information, such as exact candidate sites for charging stations and other data related with electric vehicles. The methods and results of this paper can serve as a planning guideline to facilitate the extensive adoption of electric

  5. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...

  6. Physical sciences research plans for the International Space Station

    Science.gov (United States)

    Trinh, E. H.

    2003-01-01

    The restructuring of the research capabilities of the International Space Station has forced a reassessment of the Physical Sciences research plans and a re-targeting of the major scientific thrusts. The combination of already selected peer-reviewed flight investigations with the initiation of new research and technology programs will allow the maximization of the ISS scientific and technological potential. Fundamental and applied research will use a combination of ISS-based facilities, ground-based activities, and other experimental platforms to address issues impacting fundamental knowledge, industrial and medical applications on Earth, and the technology required for human space exploration. The current flight investigation research plan shows a large number of principal investigators selected to use the remaining planned research facilities. c2003 American Institute of Aeronautics and Astronautics. Published by Elsevier Science Ltd. All rights reserved.

  7. Mechanics of wafer bonding: Effect of clamping

    Science.gov (United States)

    Turner, K. T.; Thouless, M. D.; Spearing, S. M.

    2004-01-01

    A mechanics-based model is developed to examine the effects of clamping during wafer bonding processes. The model provides closed-form expressions that relate the initial geometry and elastic properties of the wafers to the final shape of the bonded pair and the strain energy release rate at the interface for two different clamping configurations. The results demonstrate that the curvature of bonded pairs may be controlled through the use of specific clamping arrangements during the bonding process. Furthermore, it is demonstrated that the strain energy release rate depends on the clamping configuration and that using applied loads usually leads to an undesirable increase in the strain energy release rate. The results are discussed in detail and implications for process development and bonding tool design are highlighted.

  8. Evaluation of clamp effects on LMFBR piping systems

    International Nuclear Information System (INIS)

    Jones, G.L.

    1980-01-01

    Loop-type liquid metal breeder reactor plants utilize thin-wall piping to mitigate through-wall thermal gradients due to rapid thermal transients. These piping loops require a support system to carry the combined weight of the pipe, coolant and insulation and to provide attachments for seismic restraints. The support system examined here utilizes an insulated pipe clamp designed to minimize the stresses induced in the piping. To determine the effect of these clamps on the pipe wall a non-linear, two-dimensional, finite element model of the clamp, insulation and pipe wall was used to determine the clamp/pipe interface load distributions which were then applied to a three-dimensional, finite element model of the pipe. The two-dimensional interaction model was also utilized to estimate the combined clamp/pipe stiffness

  9. Load-deflection characteristics of small-bore insulated-pipe clamps

    International Nuclear Information System (INIS)

    Severud, L.K.; Clark, G.L.

    1981-12-01

    The special insulated clamps used on both FFTF and CRBR piping utilize a Belleville spring arrangement to compensate for pipe thermal expansion. Analysis indicates that this produces a non-linear, directionally sensitive clamp spring rate. Since these spring rates influence the seismic response of a supported piping system, it was deemed necessary to evaluate them further by test. This has been accomplished for the FFTF clamps. A more standard insulated pipe clamp, which does not incorporate Belleville springs to accommodate thermal expansion, was also tested. This type clamp is simple in design, and economically attractive. It may have wide application prospects for use in LMFBR small bore auxiliary piping operating at temperatures below 427 0 C. Load deflection tests were conducted on 2.54 CM and 7.62 CM diameter samples of these commercial clamps

  10. Load-deflection characteristics of small bore insulated pipe clamps

    International Nuclear Information System (INIS)

    Severud, L.K.; Clark, G.L.

    1982-01-01

    High temperature LMFBR piping is subject to rapid temperature changes during transient events. Typically, this pipe is supported by specially designed insulated pipe clamps to prevent excessive thermal stress from developing during these transients. The special insulated clamps used on both FFTF and CRBR piping utilize a Belleville spring arrangement to compensate for pipe thermal expansion. Analysis indicates that this produces a non-linear, directionally sensitive clamp spring rate. Since these spring rates influence the seismic response of a supported piping system, it was deemed necessary to evaluate them further by test. This has been accomplished for the FFTF clamps. A more standard insulated pipe clamp, which does not incorporate Belleville springs to accommodate thermal expansion, was also tested. This type clamp is simple in design, and economically attractive. It may have wide application prospects for use in LMFBR small bore auxiliary piping operating at temperatures below 427 0 C. Load deflection tests were conducted on 2.54 CM and 7.62 CM diameter samples of these commercial clamps

  11. Loading dynamics of a sliding DNA clamp.

    KAUST Repository

    Cho, Won-Ki; Jergic, Slobodan; Kim, Daehyung; Dixon, Nicholas E; Lee, Jong-Bong

    2014-01-01

    8° during clamp closure. The single-molecule polarization and FRET studies thus revealed the real-time dynamics of the ATP-hydrolysis-dependent 3D conformational change of the β clamp during loading at a ss/dsDNA junction.

  12. Force-controlled patch clamp of beating cardiac cells.

    Science.gov (United States)

    Ossola, Dario; Amarouch, Mohamed-Yassine; Behr, Pascal; Vörös, János; Abriel, Hugues; Zambelli, Tomaso

    2015-03-11

    From its invention in the 1970s, the patch clamp technique is the gold standard in electrophysiology research and drug screening because it is the only tool enabling accurate investigation of voltage-gated ion channels, which are responsible for action potentials. Because of its key role in drug screening, innovation efforts are being made to reduce its complexity toward more automated systems. While some of these new approaches are being adopted in pharmaceutical companies, conventional patch-clamp remains unmatched in fundamental research due to its versatility. Here, we merged the patch clamp and atomic force microscope (AFM) techniques, thus equipping the patch-clamp with the sensitive AFM force control. This was possible using the FluidFM, a force-controlled nanopipette based on microchanneled AFM cantilevers. First, the compatibility of the system with patch-clamp electronics and its ability to record the activity of voltage-gated ion channels in whole-cell configuration was demonstrated with sodium (NaV1.5) channels. Second, we showed the feasibility of simultaneous recording of membrane current and force development during contraction of isolated cardiomyocytes. Force feedback allowed for a gentle and stable contact between AFM tip and cell membrane enabling serial patch clamping and injection without apparent cell damage.

  13. Core clamping device for a nuclear reactor

    International Nuclear Information System (INIS)

    Guenther, R.W.

    1974-01-01

    The core clamping device for a fast neutron reactor includes clamps to support the fuel zone against the pressure vessel. The clamps are arranged around the circumference of the core. They consist of torsion bars arranged parallel at some distance around the core with lever arms attached to the ends whose force is directed in the opposite direction, pressing against the wall of the pressure vessel. The lever arms and pressure plates also actuated by the ends of the torsion bars transfer the stress, the pressure plates acting upon the fuel elements or fuel assemblies. Coupling between the ends of the torsion bars and the pressure plates is achieved by end carrier plates directly attached to the torsion bars and radially movable. This clamping device follows the thermal expansions of the core, allows specific elements to be disengaged in sections and saves space between the core and the neutron reflectors. (DG) [de

  14. Optimal Charging Schedule Planning and Economic Analysis for Electric Bus Charging Stations

    Directory of Open Access Journals (Sweden)

    Rong-Ceng Leou

    2017-04-01

    Full Text Available The battery capacity of electric buses (EB used for public transportation is greater than that of electric cars, and the charging power is also several times greater than that used in electric cars; this can result in high energy consumption and negatively impact power distribution networks. This paper proposes a framework to determine the optimal contracted power capacity and charging schedule of an EB charging station in such a way that energy costs can be reduced. A mathematical model of controlled charging, which includes the capacity and energy charges of the station, was developed to minimize costs. The constraints of the model include the charging characteristics of an EB and the operational guidelines of the bus company. A practical EB charging station was used to verify the proposed model. The financial viability of this EB charging station is also studied in this paper. The economic analysis model for this charging station considers investment and operational costs, and the operational revenue. Sensitivity analyses with respect to some key parameters are also performed in this paper. Based on actual operational routes and EB charging schemes, test results indicate that the EB charging station investment is feasible, and the planning model proposed can be used to determine optimal station power capacity and minimize energy costs.

  15. Lotus birth, a holistic approach on physiological cord clamping.

    Science.gov (United States)

    Zinsser, Laura A

    2018-04-01

    The positive effects of delayed cord clamping (DCC) has been extensively researched. DCC means: waiting at least one minute after birth before clamping and cutting the cord or till the pulsation has stopped. With physiological clamping and cutting (PCC) the clamping and cutting can happen at the earliest after the pulsation has stopped. With a Lotus birth, no clamping and cutting of the cord is done. A woman called Clair Lotus Day imitated the holistic approach of PCC from an anthropoid ape in 1974. The chimpanzee did not separate the placenta from the newborn. The aim of this case report is to discuss and learn a different approach in the third stage of labour. Three cases of Lotus birth by human beings were observed. All three women gave birth in an out-of-hospital setting and had ambulant postnatal care. The placenta was washed, salted and herbs were put on 2-3h post partum. The placenta was wrapped in something that absorbs the moisture. The salting was repeated with a degreasing frequency depending on moistness of the placenta. On life day six all three Lotus babies experiences a natural separation of the cord. All three Lotus birth cases were unproblematic, no special incidence occurred. One should differentiate between early cord clamping (ECC), delayed cord clamping (DCC) and physiological cord clamping (PCC). Lotus birth might lead to an optimisation of the bonding and attachment. Research is needed in the areas of both PCC and Lotus birth. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  16. π-Clamp-mediated cysteine conjugation

    Science.gov (United States)

    Zhang, Chi; Welborn, Matthew; Zhu, Tianyu; Yang, Nicole J.; Santos, Michael S.; van Voorhis, Troy; Pentelute, Bradley L.

    2016-02-01

    Site-selective functionalization of complex molecules is one of the most significant challenges in chemistry. Typically, protecting groups or catalysts must be used to enable the selective modification of one site among many that are similarly reactive, and general strategies that selectively tune the local chemical environment around a target site are rare. Here, we show a four-amino-acid sequence (Phe-Cys-Pro-Phe), which we call the ‘π-clamp’, that tunes the reactivity of its cysteine thiol for site-selective conjugation with perfluoroaromatic reagents. We use the π-clamp to selectively modify one cysteine site in proteins containing multiple endogenous cysteine residues. These examples include antibodies and cysteine-based enzymes that would be difficult to modify selectively using standard cysteine-based methods. Antibodies modified using the π-clamp retained binding affinity to their targets, enabling the synthesis of site-specific antibody-drug conjugates for selective killing of HER2-positive breast cancer cells. The π-clamp is an unexpected approach to mediate site-selective chemistry and provides new avenues to modify biomolecules for research and therapeutics.

  17. Experimental background of pain treatment by heat application - rapid heating and cooling in patch clamp experiments

    Czech Academy of Sciences Publication Activity Database

    Dittert, Ivan; Slovák, P.; Jíra, J.

    2005-01-01

    Roč. 8, Suppl.2 (2005), s. 32-32 ISSN 1212-0634. [Česko-Slovenské dialógy o bolesti /7./. 13.10.2005 - 15.10.2005, Bojnice] Institutional research plan: CEZ:AV0Z50110509 Keywords : patch clamp * channels Subject RIV: CF - Physical ; Theoretical Chemistry

  18. A new clamp method for firing bricks | Obeng | Journal of Applied ...

    African Journals Online (AJOL)

    A new clamp method for firing bricks. ... Journal of Applied Science and Technology ... To overcome this operational deficiencies, a new method of firing bricks that uses brick clamp technique that incorporates a clamp wall of 60 cm thickness, a six tier approach of sealing the top of the clamp (by combination of green bricks) ...

  19. IMPORTANT: Fluke is recalling Digital Clamp Meters

    CERN Multimedia

    2013-01-01

    Fluke is voluntarily recalling four models of Digital Clamp Meters: Fluke 373, 374, 375 and 376. If you own one of these clamp meters, please stop using it and send it back to Fluke for repair even if you have not experienced problems.   Description of the problem: "The printed circuit assembly may not be properly fastened to the test lead input jack. This may result in inaccurate voltage readings, including a low or no-voltage reading on a circuit energised with a hazardous voltage, presenting a shock, electrocution or thermal burn hazard." To determine if your clamp meter is affected by this recall notice, and for more information, click here.

  20. Is "Delayed Umbilical Cord Clamping" Beneficial for Premature Newborns?

    Directory of Open Access Journals (Sweden)

    Amir-Mohammad Armanian

    2017-05-01

    Full Text Available Background: The appropriate moment for clamping the umbilical cord is controversial. Immediate cord clamping (ICC is an item of active management of the third stage of labor (AMTSL. Unclamped umbilical cord may cause inconvenience in preterm neonates because they commonly need some levels of emergent services. Some studies revealed delayed cord clamping (DCC of preterm neonates results in better health conditions like lower rates of respiratory distress syndrome (RDS, less morbidities in labor room and lower risk of postpartum hemorrhage. The aim of the present study was to determine the effect of delayed umbilical cord clamping on premature neonatal outcomes. Materials and Methods: In this single‑center randomized control trial study, sixty premature neonates (gestational age ≤ 34 weeks were randomly assigned to ICC (cord clamped at 5–10 seconds or DCC (30–45 seconds groups and followed up in neonatal intensive care unit (NICU. Primary outcomes were 1st and 5th minute Apgar score, average of level of hematocrit after birth, intra ventricle hemorrhage and need some levels of resuscitation. Results: Differences in demographic characteristics were not statistically significant. After birth, neonates who had delayed clamping had significantly higher mean hematocrit after at 4-hour of birth (49.58+5.15gr/dl vs. 46.58+5.40gr/dlin DCC vs. ICC groups, respectively (P=0.031. Delayed cord clamping reduced the duration of need to nasal continues positive airway pressure (NCPAP (86.7% and 60.0% in ICC and DCC groups, respectively, P= 0.039. Attractively, the results showed lower incidence of clinical sepsis in delayed cord clamping neonates (53.3% vs. 23.3% in ICC and DCC groups, respectively, P=0.033. Conclusion: Prematurity complications might decrease by delay umbilical cord clamping which improve the hematocrit, duration of need to NCPAP and incidence of clinical sepsis. Furthermore, DCC may have no negative impact on neonatal resuscitation.

  1. A missing factor in chip-based patch clamp assay: gigaseal

    International Nuclear Information System (INIS)

    Ong, W-L; Yobas, L; Ong, W-Y

    2006-01-01

    The 'gold' standard in the study of ionic currents across biological membranes is the Patch Clamp method. However, this is a slow, labor and skill intensive process. High throughput patch clamp devices are mainly chip-based. A major challenge in these miniaturized devices is the low rate of 'Gigaseal' formation which is critical in the study of Single Channel effect. In a conventional patch clamp, a pipette moves and patches a fixed cell (cell-adhered patch) which is grown on the bottom of a Petri dish. In the chip-based case, the cells are in suspension and move towards the fixed patch clamp sites (cell-suspended patch). In this study, using the proven conventional patch clamp setup, we investigated the effect of the differences in the cell configurations between the convention patch clamp and cell-based patch clamp. It is shown that adhered cells (as used in the conventional setup) have a much higher rate of gigaseal formation as compared to the cells in suspension (as used in chip-based devices). We postulate that the arrangement of the cytoskeleton within the cell plays a major part in the formation of the gigaseal

  2. Patch-Clamp Recording from Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes: Improving Action Potential Characteristics through Dynamic Clamp

    Science.gov (United States)

    Veerman, Christiaan C.; Zegers, Jan G.; Mengarelli, Isabella; Bezzina, Connie R.

    2017-01-01

    Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) hold great promise for studying inherited cardiac arrhythmias and developing drug therapies to treat such arrhythmias. Unfortunately, until now, action potential (AP) measurements in hiPSC-CMs have been hampered by the virtual absence of the inward rectifier potassium current (IK1) in hiPSC-CMs, resulting in spontaneous activity and altered function of various depolarising and repolarising membrane currents. We assessed whether AP measurements in “ventricular-like” and “atrial-like” hiPSC-CMs could be improved through a simple, highly reproducible dynamic clamp approach to provide these cells with a substantial IK1 (computed in real time according to the actual membrane potential and injected through the patch-clamp pipette). APs were measured at 1 Hz using perforated patch-clamp methodology, both in control cells and in cells treated with all-trans retinoic acid (RA) during the differentiation process to increase the number of cells with atrial-like APs. RA-treated hiPSC-CMs displayed shorter APs than control hiPSC-CMs and this phenotype became more prominent upon addition of synthetic IK1 through dynamic clamp. Furthermore, the variability of several AP parameters decreased upon IK1 injection. Computer simulations with models of ventricular-like and atrial-like hiPSC-CMs demonstrated the importance of selecting an appropriate synthetic IK1. In conclusion, the dynamic clamp-based approach of IK1 injection has broad applicability for detailed AP measurements in hiPSC-CMs. PMID:28867785

  3. Saltwell Leak Detector Station Programmable Logic Controller (PLC) Software Configuration Management Plan (SCMP)

    International Nuclear Information System (INIS)

    WHITE, K.A.

    2000-01-01

    This document provides the procedures and guidelines necessary for computer software configuration management activities during the operation and maintenance phases of the Saltwell Leak Detector Stations as required by HNF-PRO-309/Rev.1, Computer Software Quality Assurance, Section 2.4, Software Configuration Management. The software configuration management plan (SCMP) integrates technical and administrative controls to establish and maintain technical consistency among requirements, physical configuration, and documentation for the Saltwell Leak Detector Station Programmable Logic Controller (PLC) software during the Hanford application, operations and maintenance. This SCMP establishes the Saltwell Leak Detector Station PLC Software Baseline, status changes to that baseline, and ensures that software meets design and operational requirements and is tested in accordance with their design basis

  4. Reducing blood loss during laparoscopic myomectomy by temporary uterine artery clamping using bulldog clamp

    Directory of Open Access Journals (Sweden)

    Kai-Jo Chiang

    2014-01-01

    Full Text Available Uterine myoma is the most common benign gynecologic tumor worldwide. Mini-invasive surgery has become popular for myomectomy, with advantages over laparotomy. However, reducing blood loss during laparoscopic myomectomy is a major concern for the surgeon because of the limitation in making a quick control bleeding during the operation. Several methods have proved to decrease blood flow, but are not always effective or available. We present a case of uterine myoma with the uterine arteries clamped by bulldog clamps during laparoscopic myomectomy. The myoma was removed successfully with minimal blood loss (<50 ml during the operation. This is an effective, safe, and reliable method for reducing bleeding during laparoscopic myomectomy that does not require ligation of the uterine artery.

  5. Planar patch clamp: advances in electrophysiology.

    Science.gov (United States)

    Brüggemann, Andrea; Farre, Cecilia; Haarmann, Claudia; Haythornthwaite, Ali; Kreir, Mohamed; Stoelzle, Sonja; George, Michael; Fertig, Niels

    2008-01-01

    Ion channels have gained increased interest as therapeutic targets over recent years, since a growing number of human and animal diseases have been attributed to defects in ion channel function. Potassium channels are the largest and most diverse family of ion channels. Pharmaceutical agents such as Glibenclamide, an inhibitor of K(ATP) channel activity which promotes insulin release, have been successfully sold on the market for many years. So far, only a small group of the known ion channels have been addressed as potential drug targets. The functional testing of drugs on these ion channels has always been the bottleneck in the development of these types of pharmaceutical compounds.New generations of automated patch clamp screening platforms allow a higher throughput for drug testing and widen this bottleneck. Due to their planar chip design not only is a higher throughput achieved, but new applications have also become possible. One of the advantages of planar patch clamp is the possibility of perfusing the intracellular side of the membrane during a patch clamp experiment in the whole-cell configuration. Furthermore, the extracellular membrane remains accessible for compound application during the experiment.Internal perfusion can be used not only for patch clamp experiments with cell membranes, but also for those with artificial lipid bilayers. In this chapter we describe how internal perfusion can be applied to potassium channels expressed in Jurkat cells, and to Gramicidin channels reconstituted in a lipid bilayer.

  6. Analysis of the role of PCNA-DNA contacts during clamp loading

    Directory of Open Access Journals (Sweden)

    Goedken Eric R

    2010-01-01

    Full Text Available Abstract Background Sliding clamps, such as Proliferating Cell Nuclear Antigen (PCNA in eukaryotes, are ring-shaped protein complexes that encircle DNA and enable highly processive DNA replication by serving as docking sites for DNA polymerases. In an ATP-dependent reaction, clamp loader complexes, such as the Replication Factor-C (RFC complex in eukaryotes, open the clamp and load it around primer-template DNA. Results We built a model of RFC bound to PCNA and DNA based on existing crystal structures of clamp loaders. This model suggests that DNA would enter the clamp at an angle during clamp loading, thereby interacting with positively charged residues in the center of PCNA. We show that simultaneous mutation of Lys 20, Lys 77, Arg 80, and Arg 149, which interact with DNA in the RFC-PCNA-DNA model, compromises the ability of yeast PCNA to stimulate the DNA-dependent ATPase activity of RFC when the DNA is long enough to extend through the clamp. Fluorescence anisotropy binding experiments show that the inability of the mutant clamp proteins to stimulate RFC ATPase activity is likely caused by reduction in the affinity of the RFC-PCNA complex for DNA. We obtained several crystal forms of yeast PCNA-DNA complexes, measuring X-ray diffraction data to 3.0 Å resolution for one such complex. The resulting electron density maps show that DNA is bound in a tilted orientation relative to PCNA, but makes different contacts than those implicated in clamp loading. Because of apparent partial disorder in the DNA, we restricted refinement of the DNA to a rigid body model. This result contrasts with previous analysis of a bacterial clamp bound to DNA, where the DNA was well resolved. Conclusion Mutational analysis of PCNA suggests that positively charged residues in the center of the clamp create a binding surface that makes contact with DNA. Disruption of this positive surface, which had not previously been implicated in clamp loading function, reduces RFC

  7. File list: Oth.ALL.50.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.50.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159172,SRX15917...0,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.50.Clamp.AllCell.bed ...

  8. Land use planning using transit oriented development concept: Case study: Salaya station

    Science.gov (United States)

    Jarritthai, Supanee; Techpeeraparnich, Wasaporn

    2017-10-01

    The urban sprawl of Bangkok has increased with a motorization rate along with the expansion of the road network to adjacent cities. Nakhonpathom province, located at the southern edge of Bangkok has been affected by the urban sprawl. One of Nakhonpathom's Districts named "Salaya" Salaya has been quickly urbanized due to the establishment of many large academic institutes, such as universities, colleges and high schools as well as many commercial shopping malls. The period of 2013-2017, the Thai government introduced sustainable urban planning policy and promoted the use of public transportation systems. The Light Red Line railway extension of the Bangkok Metro Transit system will soon be constructed and the current Salaya Station will be replaced with new station. Many railway expansion projects will be built, should be designed by using transit-oriented development (TOD) scheme. This paper explores demographic information of the area, the demands of the community and relevant stakeholders for designing of the area using TOD. The proposed land use planning is designed based on the existing condition of the area as much as possible to meet the TOD standard and stakeholders' requirement. The result revealed that the guidelines of transit oriented development concept were of importance not only for planning of urban land use, supporting public transport, but also improving the quality of life.

  9. The planning of areas near nuclear power stations

    International Nuclear Information System (INIS)

    1977-01-01

    During the past five years national physical planning has been initiated by the Swedish Parliament. Guidelines have been given to the communities how to consider national interests when drawing up local planning and how to produce maps and descriptions of the planning. For the planning of the areas near the nuclear power stations the municipalities have certain guidelines from The Nuclear Power Inspectorate and The National Institute of Radiation Protection. It is advised to keep a low population density near the power plants, to avoid the type of harbour or industry which could have disturbing effects on the power plant and also to avoid to concentrate people, who are difficult to move from the area in case of an accident (i.e., homes for old people, maternity homes and prisons). The plants on the East Coast, Forsmark and Oskarshamn, are located in wooded areas with a very low population density. On the West Coast, near Ringhals and Barsebaeck, the population density is higher, and there is one village with about 2,000 inhabitants, situated at a distance of two (2) km from the Ringhals power plant. The Control Boards are now reluctant to concentrate more people in this village, where schools and shops were earlier planned for 3,000 inhabitants. The building activity near power plants is regulated by law. New buildings are prohibited within a distance of two (2) km from the plants. Some exeptions can be granted by the County Administrative Board after guidance from the Central Board. In a zone reaching 10 kilometers from the power plants there are no regulations by law about new buildings, except the earlier mentioned guidelines from the Central Boards to maintain a low population. (L.E.)

  10. INTERACT Management planning for arctic and northern alpine stations - Examples of good practices

    DEFF Research Database (Denmark)

    of visitors, outreach, science plans, data management and education. The target audience for the book is mainly managers of research stations in arctic and alpine areas, but it is our hope that it will also be a useful tool for others being involved in science coordination and logistics....

  11. Modeling of SVM Diode Clamping Three-Level Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    PLECS is used to model the diode clamping three-level inverter connected to grid and good results are obtained. First the output voltage SVM is described for diode clamping three-level inverter with loads connected to Y. Then the output voltage SVM of diode clamping three-level inverter is simply...... analyzed with loads connected to △. But it will be further researched in the future. Third, PLECS is briefly introduced. Fourth, the modeling of diode clamping three-level inverter is briefly presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS...... is very powerful tool to real power circuits and it is very easy to simulate them. They have also verified that SVM control strategy is feasible to control the diode clamping three-level inverter....

  12. SU-F-BRD-08: Guaranteed Epsilon-Optimal Treatment Plans with Minimum Number of Beams for SBRT Using RayStation

    International Nuclear Information System (INIS)

    Yarmand, H; Winey, B; Craft, D

    2014-01-01

    Purpose: To efficiently find quality-guaranteed treatment plans with the minimum number of beams for stereotactic body radiation therapy using RayStation. Methods: For a pre-specified pool of candidate beams we use RayStation (a treatment planning software for clinical use) to identify the deliverable plan which uses all the beams with the minimum dose to organs at risk (OARs) and dose to the tumor and other structures in specified ranges. Then use the dose matrix information for the generated apertures from RayStation to solve a linear program to find the ideal plan with the same objective and constraints allowing use of all beams. Finally we solve a mixed integer programming formulation of the beam angle optimization problem (BAO) with the objective of minimizing the number of beams while remaining in a predetermined epsilon-optimality of the ideal plan with respect to the dose to OARs. Since the treatment plan optimization is a multicriteria optimization problem, the planner can exploit the multicriteria optimization capability of RayStation to navigate the ideal dose distribution Pareto surface and select a plan of desired target coverage versus OARs sparing, and then use the proposed technique to reduce the number of beams while guaranteeing quality. For the numerical experiments two liver cases and one lung case with 33 non-coplanar beams are considered. Results: The ideal plan uses an impractically large number of beams. The proposed technique reduces the number of beams to the range of practical application (5 to 9 beams) while remaining in the epsilon-optimal range of 1% to 5% optimality gap. Conclusion: The proposed method can be integrated into a general algorithm for fast navigation of the ideal dose distribution Pareto surface and finding the treatment plan with the minimum number of beams, which corresponds to the delivery time, in epsilon-optimality range of the desired ideal plan. The project was supported by the Federal Share of program income

  13. SU-F-BRD-08: Guaranteed Epsilon-Optimal Treatment Plans with Minimum Number of Beams for SBRT Using RayStation

    Energy Technology Data Exchange (ETDEWEB)

    Yarmand, H; Winey, B; Craft, D [Massachusetts General Hospital, Boston, MA (United States)

    2014-06-15

    Purpose: To efficiently find quality-guaranteed treatment plans with the minimum number of beams for stereotactic body radiation therapy using RayStation. Methods: For a pre-specified pool of candidate beams we use RayStation (a treatment planning software for clinical use) to identify the deliverable plan which uses all the beams with the minimum dose to organs at risk (OARs) and dose to the tumor and other structures in specified ranges. Then use the dose matrix information for the generated apertures from RayStation to solve a linear program to find the ideal plan with the same objective and constraints allowing use of all beams. Finally we solve a mixed integer programming formulation of the beam angle optimization problem (BAO) with the objective of minimizing the number of beams while remaining in a predetermined epsilon-optimality of the ideal plan with respect to the dose to OARs. Since the treatment plan optimization is a multicriteria optimization problem, the planner can exploit the multicriteria optimization capability of RayStation to navigate the ideal dose distribution Pareto surface and select a plan of desired target coverage versus OARs sparing, and then use the proposed technique to reduce the number of beams while guaranteeing quality. For the numerical experiments two liver cases and one lung case with 33 non-coplanar beams are considered. Results: The ideal plan uses an impractically large number of beams. The proposed technique reduces the number of beams to the range of practical application (5 to 9 beams) while remaining in the epsilon-optimal range of 1% to 5% optimality gap. Conclusion: The proposed method can be integrated into a general algorithm for fast navigation of the ideal dose distribution Pareto surface and finding the treatment plan with the minimum number of beams, which corresponds to the delivery time, in epsilon-optimality range of the desired ideal plan. The project was supported by the Federal Share of program income

  14. Crystal structure of DNA polymerase III β sliding clamp from Mycobacterium tuberculosis.

    Science.gov (United States)

    Gui, Wen-Jun; Lin, Shi-Qiang; Chen, Yuan-Yuan; Zhang, Xian-En; Bi, Li-Jun; Jiang, Tao

    2011-02-11

    The sliding clamp is a key component of DNA polymerase III (Pol III) required for genome replication. It is known to function with diverse DNA repair proteins and cell cycle-control proteins, making it a potential drug target. To extend our understanding of the structure/function relationship of the sliding clamp, we solved the crystal structure of the sliding clamp from Mycobacterium tuberculosis (M. tuberculosis), a human pathogen that causes most cases of tuberculosis (TB). The sliding clamp from M. tuberculosis forms a ring-shaped head-to-tail dimer with three domains per subunit. Each domain contains two α helices in the inner ring that lie against two β sheets in the outer ring. Previous studies have indicated that many Escherichia coli clamp-binding proteins have a conserved LF sequence, which is critical for binding to the hydrophobic region of the sliding clamp. Here, we analyzed the binding affinities of the M. tuberculosis sliding clamp and peptides derived from the α and δ subunits of Pol III, which indicated that the LF motif also plays an important role in the binding of the α and δ subunits to the sliding clamp of M. tuberculosis. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Tuning permanent magnets with adjustable field clamps

    International Nuclear Information System (INIS)

    Schermer, R.I.

    1987-01-01

    The effective length of a permanent-magnet assembly can be varied by adjusting the geometrical parameters of a field clamp. This paper presents measurements on a representative dipole and quadrupole as the field clamp is withdrawn axially or radially. The detailed behavior depends upon the magnet multipolarity and geometry. As a rule-of-thumb, a 3-mm-thick iron plate placed at one end plane of the magnet will shorten the length by one-third of the magnet bore radius

  16. Analysis and Experiments on Sea Load and Fastened Mechanics on Pipe Clamps

    Directory of Open Access Journals (Sweden)

    Wang Zhuo

    2017-08-01

    Full Text Available When an offshore oil field completed and put into production, new subsea pipelines and the new cable need to be established. Cable protection pipe clamp is used to fix cable protection pipe on the jacket. In order to avoid the problem of traditional steel structure clamp splice, counterpoint, fastening difficulty when installed cable protection pipe under water, reduce the risk and workload of under water, This paper develop a new type of portable connecting riser clamp -“backpack clamp” which solve the riser cable protection pipe difficult underwater installation problem. The main structure of backpack clamp used three valves type structure. The load characteristic of a clamping device was determined by the Morison equation which was a classical theory. Clamp device underwater mechanics analysis model was established. The minimum tension pre-tightening force was determined. The results show that the strength of the base meets the requirements after strength analysis with finite element analysis method, stability and strength experiments, which means the clamp based on resin matrix composite is feasible.

  17. Active energy recovery clamping circuit to improve the performance of power converters

    Science.gov (United States)

    Whitaker, Bret; Barkley, Adam

    2017-05-09

    A regenerative clamping circuit for a power converter using clamping diodes to transfer charge to a clamping capacitor and a regenerative converter to transfer charge out of the clamping capacitor back to the power supply input connection. The regenerative converter uses a switch connected to the midpoint of a series connected inductor and capacitor. The ends of the inductor and capacitor series are connected across the terminals of the power supply to be in parallel with the power supply.

  18. Relationship between regional planning and site finding of power stations with regard to energy supply

    International Nuclear Information System (INIS)

    Hoppe, I.

    1980-01-01

    Based on the discussion on energy policy generally brought in the fore, spatial relationships are discussed especially in the field of electricity supply. A review is given of the legal systematism in which electricity supply and regional planning are to be found. How state planners organize the provision with sites for high-capacity thermal power stations is described as the concrete development of systematic legal relationships, concepts of, and opportunities for, state and regional planning. In the main part, this paper focusses on the analysis of the course of development power station construction and the distribution system have taken with regard to the question as to whether and to what extent this technological character is also responsible for an emerging structure in which these plants are mainly centred in a special region. (orig.) [de

  19. File list: Oth.CeL.50.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CeL.50.Clamp.AllCell dm3 TFs and others Clamp Cell line SRX159172,SRX159170,SRX...159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.CeL.50.Clamp.AllCell.bed ...

  20. File list: Oth.CeL.05.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CeL.05.Clamp.AllCell dm3 TFs and others Clamp Cell line SRX159172,SRX159170,SRX...159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.CeL.05.Clamp.AllCell.bed ...

  1. [Analysis of brain hemometabolism behavior during carotid endarterectomy with temporary clamping.].

    Science.gov (United States)

    Duval Neto, Gastão Fernandes; Niencheski, Augusto H

    2004-04-01

    Carotid endarterectomy with temporary clamping changes cerebral blood flow and cerebral metabolic oxygen demand ratio with consequent oligemic hypoxia or hemometabolic uncoupling. This study aimed at identifying changes in brain hemometabolism, evaluated through changes in oxyhemoglobin saturation in internal jugular vein bulb (SvjO2) during carotid endarterectomy with clamping, and at correlating these changes with potentially interfering factors, mainly end tidal CO2 pressure (P ET CO2) and cerebral perfusion pressure (CPP). Sixteen patients with unilateral carotid stenotic disease scheduled to carotid endarterectomy with carotid arterial clamping were enrolled in this study. Parameters including internal jugular bulb oxyhemoglobin saturation, stump pressure and end tidal CO2 pressure were measured at the following moments: M1 - pre-clamping; M2 - 3 minutes after clamping; M3 - pre-unclamping; M4 - post-unclamping). The comparison among SvjO2 (%, mean +/- SD) in all studied periods has shown differences between those recorded in moments M1 (52.25 +/- 7.87) and M2 (47.43 +/- 9.19). This initial decrease stabilized during temporary clamping, showing decrease in the comparison between M2 and M3 (46.56 +/- 9.25), without statistical significance (p = ns). At post-unclamping, M4 (47.68 +/- 9.12), SvjO2 was increased as compared to M2 and M3 clamping stages, however it was still lower than that of pre-clamping stage M1.(M4 x M1 - p brain hemometabolic uncoupling trend were correlated to P ET CO2. The comparison between CPP and SvjO2 showed weak correlation devoid of statistical significance. In the conditions of our study, SvjO2 measurement is a fast and effective way of clinically monitoring changes in CBF/CMRO2 ratio. Temporary carotid clamping implies in a trend towards brain hemometabolic uncoupling and, as a consequence, to oligemic ischemia; cerebral perfusion pressure does not assesses brain hemometabolic status (CBF and CMRO2 ratio); hypocapnia, may lead to

  2. Computer Simulation Model to Train Medical Personnel on Glucose Clamp Procedures.

    Science.gov (United States)

    Maghoul, Pooya; Boulet, Benoit; Tardif, Annie; Haidar, Ahmad

    2017-10-01

    A glucose clamp procedure is the most reliable way to quantify insulin pharmacokinetics and pharmacodynamics, but skilled and trained research personnel are required to frequently adjust the glucose infusion rate. A computer environment that simulates glucose clamp experiments can be used for efficient personnel training and development and testing of algorithms for automated glucose clamps. We built 17 virtual healthy subjects (mean age, 25±6 years; mean body mass index, 22.2±3 kg/m 2 ), each comprising a mathematical model of glucose regulation and a unique set of parameters. Each virtual subject simulates plasma glucose and insulin concentrations in response to intravenous insulin and glucose infusions. Each virtual subject provides a unique response, and its parameters were estimated from combined intravenous glucose tolerance test-hyperinsulinemic-euglycemic clamp data using the Bayesian approach. The virtual subjects were validated by comparing their simulated predictions against data from 12 healthy individuals who underwent a hyperglycemic glucose clamp procedure. Plasma glucose and insulin concentrations were predicted by the virtual subjects in response to glucose infusions determined by a trained research staff performing a simulated hyperglycemic clamp experiment. The total amount of glucose infusion was indifferent between the simulated and the real subjects (85±18 g vs. 83±23 g; p=NS) as well as plasma insulin levels (63±20 mU/L vs. 58±16 mU/L; p=NS). The virtual subjects can reliably predict glucose needs and plasma insulin profiles during hyperglycemic glucose clamp conditions. These virtual subjects can be used to train personnel to make glucose infusion adjustments during clamp experiments. Copyright © 2017 Diabetes Canada. Published by Elsevier Inc. All rights reserved.

  3. Structural consideration for hot and cold pipe clamps in LMFBR applications

    International Nuclear Information System (INIS)

    Anderson, M.J.; Huang, S.N.; Kappauf, H.; Wagner, S.E.; Wirtz, K.H.

    1983-01-01

    A series of analytical studies are described which evaluate stress levels induced in a 600 mm high temperature, thin-wall sodium pipeline by two alternate clamp designs. The first design consists of a band mounted directly on the pipe and is called the hot clamp. The second design consists of a band mounted using insulation standoffs and is called the cold clamp. Pipe stress levels induced by transient thermal dead weight and seismic loads are discussed. Pipe stress levels and system dynamic spring rates are presented. Procedures utilized to combine clamp induced pipe stress with other short and long term pipe system stresses are detailed. Recommendations for practical application in LMFBR pipe systems are made

  4. Structural considerations for hot and cold pipe clamps in LMFBR applications

    International Nuclear Information System (INIS)

    Anderson, M.J.; Huang, S.N.; Wagner, S.E.; Kappauf, H.; Wirtz, K.H.

    1983-01-01

    A series of analytical studies are described which evaluate stress levels induced in a 600 mm high temperature, thin-wall sodium pipeline by two alternate clamp designs. The first design consists of a band mounted directly on the pipe and is called the hot clamp. The second design consists of a band mounted using insulation standoffs and is called the cold clamp. Pipe stress levels induced by transient thermal dead weight and seismic loads are discussed. Pipe stress levels and system dynamic spring rates are presented. Procedures utilized to combine clamp induced pipe stress with other short and long term pipe system stresses are detailed. Recommendations for practical application in LMFBR pipe systems are made

  5. Investigation of the Dynamics of a Clamped-Clamped Microbeam Near the Third Mode Using a Partial Electrode

    KAUST Repository

    Masri, Karim M.

    2014-08-17

    We present an investigation of the dynamics of a clamped-clamped microbeam excited electrostatically near its third mode. To maximize the response at the third mode, a partial electrode configuration is utilized. A multi-mode Galerkin method is used to develop a reduced order model (ROM) of the beam. A shooting method to find the periodic motion is utilized to generate frequency response curves. The curves show hardenining behavior and dynamic pull-in. We show that the dynamic amplitude of the partial configuration is higher than that of a full electrode configuration. These results are promising for the use of higher-order modes for mass detection and for ultra sensitive resonant sensors.

  6. Investigation of the Dynamics of a Clamped-Clamped Microbeam Near the Third Mode Using a Partial Electrode

    KAUST Repository

    Masri, Karim M.; Younis, Mohammad I.

    2014-01-01

    We present an investigation of the dynamics of a clamped-clamped microbeam excited electrostatically near its third mode. To maximize the response at the third mode, a partial electrode configuration is utilized. A multi-mode Galerkin method is used to develop a reduced order model (ROM) of the beam. A shooting method to find the periodic motion is utilized to generate frequency response curves. The curves show hardenining behavior and dynamic pull-in. We show that the dynamic amplitude of the partial configuration is higher than that of a full electrode configuration. These results are promising for the use of higher-order modes for mass detection and for ultra sensitive resonant sensors.

  7. Change in perception of people towards a nuclear emergency plan for a nuclear power station after being presented

    International Nuclear Information System (INIS)

    Kouzen, Hideharu

    2017-01-01

    We conducted a group interview survey for 24 persons living in urban areas of the Kansai region to understand the change in their perception of information about nuclear emergency plans for nuclear power stations. The participants were given descriptions about a nuclear emergency plan based on plans that had been prepared by the national government and local government. Before hearing the explanation about the nuclear emergency plan, we found that only a few participants were concerned about it, but no one knew the detailed contents. For the question 'Do you think the nuclear emergency plan is being improved after the Fukushima Daiichi Nuclear Power Plant accident?', we found 6 persons among the 24 held opinions saying that the plan was 'improved' or 'somewhat improved'. However, after hearing the explanation and a brief Q and A session about it, 18 persons held opinions saying the plan was 'improved' or 'somewhat improved'. As the reason for such answers, the most common opinion shared by 13 persons was that 'a nuclear emergency plan is being made'. There is a possibility that urban residents had not known the facts about specific disaster prevention plans for each nuclear power station that have been formulated. (author)

  8. Do cities deserve more railway stations? The choice of a departure railway station in a multiple-station region

    NARCIS (Netherlands)

    Givoni, M.; Rietveld, P.

    2014-01-01

    Promoting the use of rail is an important element in sustainable transport policy. One of the most important decisions to make in planning the railway network is on the number of stations to provide. Stations are the access points to rail services and while each additional station increases rail's

  9. Initial Remedial Action Plan for Expanded Bioventing System BX Service Station, Patrick Air Force Base, Florida

    National Research Council Canada - National Science Library

    1995-01-01

    This initial remedial action plan presents the scope for an expanded bioventing system for in situ treatment of fuel-contaminated soils at the BX Service Station at Patrick Air Force Base (AFB), Florida...

  10. COMPARISON OF EARLY AND DELAYED UMBILICAL CORD CLAMPING IN THE THIRD STAGE OF LABOUR

    Directory of Open Access Journals (Sweden)

    Tamara Serdinšek

    2015-09-01

    Full Text Available Background: Umbilical cord clamping in the third stage of labour is still controversial. Early cord clamping is defined as clamping at 10, 15, 30 or 60 seconds after delivery and delayed as clamping after 60 seconds or at 2-5 minutes after delivery, when the cord stops pulsating or when the placenta is visible within the birth canal. Early clamping is one of the three components of active management of the third stage of labour, which has been used widely in modern obstetrics during the last century. However, in some northern European countries, various parts of the USA and Canada and in developing countries physiological management is preferred.Conclusions: After publication of several trials describing advantages of delayed clamping, this has recently been progressively replacing early clamping. The most important advantages of delayed cord clamping are higher haemoglobin and ferritin levels, higher iron stores, lower incidence of iron deficiency anaemia, better cardiopulmonary adaptation, lower rate of respiratory distress syndrome, and longer duration of early breastfeeding in term neonates, while there is no increase in the incidence of postpartum haemorrhage. Delayed clamping seems to bring some advantages for preterm neonates as well. However, caution is still advised because of the potential adverse effects, especially polycythaemia with hyperviscosity, hyperbilirubinaemia and respiratory distress.

  11. Different methods of hilar clamping during partial nephrectomy: Impact on renal function.

    Science.gov (United States)

    Lee, Jeong Woo; Kim, Hwanik; Choo, Minsoo; Park, Yong Hyun; Ku, Ja Hyeon; Kim, Hyeon Hoe; Kwak, Cheol

    2014-03-01

    To evaluate the impact of different hilar clamping methods on changes in renal function after partial nephrectomy. We analyzed the clinical data of 369 patients who underwent partial nephrectomy for a single renal tumor of size ≤4.0 cm and a normal contralateral kidney. Patients were separated into three groups depending on hilar clamping method: non-clamping, cold ischemia and warm ischemia. Estimated glomerular filtration rate was examined at preoperative, nadir and 1 year postoperatively. Percent change in estimated glomerular filtration rate was used as the parameter to assess the renal functional outcome. Percent change in nadir estimated glomerular filtration rate in the non-clamping group was significantly less compared with the cold ischemia and warm ischemia groups (P hilar clamping (both warm ischemia and cold ischemia) were significantly associated with percent change in nadir estimated glomerular filtration rate, but not in 1-year estimated glomerular filtration rate. Non-clamping partial nephrectomy results in a lower percent change in nadir estimated glomerular filtration rate, whereas it carries an estimated glomerular filtration rate change at 1 year that is similar to partial nephrectomy with cold ischemia and warm ischemia. Cold ischemia and warm ischemia provide a similar effect on renal function. Therefore, when hilar clamping is required, minimization of ischemia time is necessary. © 2013 The Japanese Urological Association.

  12. A trajectory planning scheme for spacecraft in the space station environment. M.S. Thesis - University of California

    Science.gov (United States)

    Soller, Jeffrey Alan; Grunwald, Arthur J.; Ellis, Stephen R.

    1991-01-01

    Simulated annealing is used to solve a minimum fuel trajectory problem in the space station environment. The environment is special because the space station will define a multivehicle environment in space. The optimization surface is a complex nonlinear function of the initial conditions of the chase and target crafts. Small permutations in the input conditions can result in abrupt changes to the optimization surface. Since no prior knowledge about the number or location of local minima on the surface is available, the optimization must be capable of functioning on a multimodal surface. It was reported in the literature that the simulated annealing algorithm is more effective on such surfaces than descent techniques using random starting points. The simulated annealing optimization was found to be capable of identifying a minimum fuel, two-burn trajectory subject to four constraints which are integrated into the optimization using a barrier method. The computations required to solve the optimization are fast enough that missions could be planned on board the space station. Potential applications for on board planning of missions are numerous. Future research topics may include optimal planning of multi-waypoint maneuvers using a knowledge base to guide the optimization, and a study aimed at developing robust annealing schedules for potential on board missions.

  13. Hinkley Point 'C' power station public inquiry: proof of evidence on emergency planning

    International Nuclear Information System (INIS)

    Western, D.J.

    1988-09-01

    A public inquiry has been set up to examine the planning application made by the Central Electricity Generating Board (CEGB) for the construction of a 1200 MW Pressurized Water Reactor power station at Hinkley Point (Hinkley Point ''C'') in the United Kingdom, adjacent to an existing nuclear power station incorporating Magnox and Advanced Gas Cooled reactors. The CEGB evidence to the Inquiry presented here introduces the concept of the Reference Accident as the basis for emergency arrangements. The description which follows of the emergency arrangements at the Hinkley Point site include: the respective responsibilities and their co-ordination of bodies such as the CEGB, external emergency services and government departments; the site emergency organization; practical aspects of the emergency arrangements; and consideration of the extension of the arrangements to a PWR on the same site. Recent developments in emergency planning, such as those arising out of post Chernobyl reviews and the Sizewell ''B'' PWR Inquiry, are taken into account. The conclusion is reached that soundly based emergency arrangements already exist at Hinkley Point which would require relatively minor changes should the proposed PWR be constructed. (UK)

  14. The Investigation of the Corrosion Resistance of the Tension Clamps Skl14

    Directory of Open Access Journals (Sweden)

    Marek Pětioký

    2015-05-01

    Full Text Available At the level crossings it is possible to find the problems with the corrosion of the parts of the fastening system. These problems are especially at the rubber level crossings and in the tunnels. As a part of the thesis the problem of the corrosion of the tension clamp Skl14 of the producer Vossloh at the rubber level crossings is examined. For the purposes of the comparison the tension clamps without the corrosion protection and the tension clamps with the corrosion protection KTL were examined. As a first step the corrosion features of the tension clamps Skl14 were solved. The examination was divided into two parts. First part it was the examination according to ČSN EN ISO 9227. The samples of the tension clamps were putted into the corrosion chamber. After 1728 h the results of the corrosion impacts were not satisfied. It was decided for the second step of the examination. It was the immersion in an electrolyte solution. As a result of the paper the corrosion features of the tension clamps without the corrosion protection and with the corrosion protection are compared.

  15. U.S. Materials Science on the International Space Station: Status and Plans

    Science.gov (United States)

    Chiaramonte, Francis P.; Kelton, Kenneth F.; Matson, Douglas M.; Poirier, David R.; Trivedi, Rohit K.; Su, Ching-Hua; Volz, Martin P.; Voorhees, Peter W.

    2010-01-01

    This viewgraph presentation reviews the current status and NASA plans for materials science on the International Space Station. The contents include: 1) Investigations Launched in 2009; 2) DECLIC in an EXPRESS rack; 3) Dynamical Selection of Three-Dimensional Interface Patterns in Directional Solidification (DSIP); 4) Materials Science Research Rack (MSRR); 5) Materials Science Laboratory; 6) Comparison of Structure and Segregation in Alloys Directionally Solidified in Terrestrial and Microgravity Environments (MICAST/CETSOL); 7) Coarsening in Solid Liquid Mixtures 2 Reflight (CSLM 2R); 8) Crystal Growth Investigations; 9) Levitator Investigations; 10) Quasi Crystalline Undercooled Alloys for Space Investigation (QUASI); 11) The Role of Convection and Growth Competition in Phase Selection in Microgravity (LODESTARS); 12) Planned Additional Investigations; 13) SETA; 14) METCOMP; and 15) Materials Science NRA.

  16. Optimal planning of electric vehicle charging station at the distribution system using hybrid optimization algorithm

    DEFF Research Database (Denmark)

    Awasthi, Abhishek; Venkitusamy, Karthikeyan; Padmanaban, Sanjeevikumar

    2017-01-01

    India's ever increasing population has made it necessary to develop alternative modes of transportation with electric vehicles being the most preferred option. The major obstacle is the deteriorating impact on the utility distribution system brought about by improper setup of these charging...... stations. This paper deals with the optimal planning (siting and sizing) of charging station infrastructure in the city of Allahabad, India. This city is one of the upcoming smart cities, where electric vehicle transportation pilot project is going on under Government of India initiative. In this context......, a hybrid algorithm based on genetic algorithm and improved version of conventional particle swarm optimization is utilized for finding optimal placement of charging station in the Allahabad distribution system. The particle swarm optimization algorithm re-optimizes the received sub-optimal solution (site...

  17. Four- year thyroidectomy procedures: Ligasure Vs. clamp & tie

    Directory of Open Access Journals (Sweden)

    Pazoki AR

    2010-01-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: The electrothermal bipolar vessel sealing system is an adjunct to the hemostatic technique, which has been successfully used in many abdominal operation, recently made available to thyroid surgery. The purpose of this was compare the outcomes of new hemostatic technique with traditional method of clamp and tie."n"nMethods: In this retrospective cross-sectional study has been done in surgery's wards of Milad & Rasul- Akram hospitals in Tehran, Iran. During three- year period between 2005-2008 all patients with different kind of pathology that need operation were assessed. Time duration of surgery and hospital stay and post surgery complication in two group, ligasure (n=45 and clamp & tie (n=145 were compared with each others."n"nResults: No difference was seen between two groups in time duration of surgery. Significant difference was seen in hospital stay and complications of surgery. Time of operation in Ligasure group was 132/22 minute and in clamp and tie group was 130/10 minute. There was found significant difference in duration of hospital stay and postoperative complication. Hypocalcemia were seen in two and 24 cases in Ligasure and Clamp & Tie group, respectively (p<0.05. Hospital stay was 2

  18. Guidelines for Learning Stations.

    Science.gov (United States)

    Fehrle, Carl C.; Schulz, Jolene

    Guidelines for designing and planning learning stations for pupils at the elementary grade level include suggestions on how to develop a station that will be successful in meeting the learners' needs. Instructions for the use of tapes at a station and matching pupils with stations are given, as are guidelines on classroom arrangement and record…

  19. Application of active electrode compensation to perform continuous voltage-clamp recordings with sharp microelectrodes.

    Science.gov (United States)

    Gómez-González, J F; Destexhe, A; Bal, T

    2014-10-01

    Electrophysiological recordings of single neurons in brain tissues are very common in neuroscience. Glass microelectrodes filled with an electrolyte are used to impale the cell membrane in order to record the membrane potential or to inject current. Their high resistance induces a high voltage drop when passing current and it is essential to correct the voltage measurements. In particular, for voltage clamping, the traditional alternatives are two-electrode voltage-clamp technique or discontinuous single electrode voltage-clamp (dSEVC). Nevertheless, it is generally difficult to impale two electrodes in a same neuron and the switching frequency is limited to low frequencies in the case of dSEVC. We present a novel fully computer-implemented alternative to perform continuous voltage-clamp recordings with a single sharp-electrode. To reach such voltage-clamp recordings, we combine an active electrode compensation algorithm (AEC) with a digital controller (AECVC). We applied two types of control-systems: a linear controller (proportional plus integrative controller) and a model-based controller (optimal control). We compared the performance of the two methods to dSEVC using a dynamic model cell and experiments in brain slices. The AECVC method provides an entirely digital method to perform continuous recording and smooth switching between voltage-clamp, current clamp or dynamic-clamp configurations without introducing artifacts.

  20. Improved DNA clamps by stacking to adjacent nucleobases

    DEFF Research Database (Denmark)

    Fatthalla, M.I.; Pedersen, Erik Bjerregaard

    2012-01-01

    Three or four aromatic rings interconnected by acetylene bridges form a stiff conjugated system with sufficient conformational freedom to make it useful to link together the two strands of a DNA clamp. Upon targeting a ssDNA, the conformational flexibility allows better stacking of the linker...... to the underlying non-planar base triplet in the formed triplex. This type of triplexes has a substantially higher thermal melting temperature which can be further improved by inserting locked nucleic acids (LNAs) in the Hoogsteen part of the clamp. An extremely high sensitivity to mismatches is observed...

  1. Inverse planning in the age of digital LINACs: station parameter optimized radiation therapy (SPORT)

    Science.gov (United States)

    Xing, Lei; Li, Ruijiang

    2014-03-01

    The last few years have seen a number of technical and clinical advances which give rise to a need for innovations in dose optimization and delivery strategies. Technically, a new generation of digital linac has become available which offers features such as programmable motion between station parameters and high dose-rate Flattening Filter Free (FFF) beams. Current inverse planning methods are designed for traditional machines and cannot accommodate these features of new generation linacs without compromising either dose conformality and/or delivery efficiency. Furthermore, SBRT is becoming increasingly important, which elevates the need for more efficient delivery, improved dose distribution. Here we will give an overview of our recent work in SPORT designed to harness the digital linacs and highlight the essential components of SPORT. We will summarize the pros and cons of traditional beamlet-based optimization (BBO) and direct aperture optimization (DAO) and introduce a new type of algorithm, compressed sensing (CS)-based inverse planning, that is capable of automatically removing the redundant segments during optimization and providing a plan with high deliverability in the presence of a large number of station control points (potentially non-coplanar, non-isocentric, and even multi-isocenters). We show that CS-approach takes the interplay between planning and delivery into account and allows us to balance the dose optimality and delivery efficiency in a controlled way and, providing a viable framework to address various unmet demands of the new generation linacs. A few specific implementation strategies of SPORT in the forms of fixed-gantry and rotational arc delivery are also presented.

  2. Inverse planning in the age of digital LINACs: station parameter optimized radiation therapy (SPORT)

    International Nuclear Information System (INIS)

    Xing, Lei; Li, Ruijiang

    2014-01-01

    The last few years have seen a number of technical and clinical advances which give rise to a need for innovations in dose optimization and delivery strategies. Technically, a new generation of digital linac has become available which offers features such as programmable motion between station parameters and high dose-rate Flattening Filter Free (FFF) beams. Current inverse planning methods are designed for traditional machines and cannot accommodate these features of new generation linacs without compromising either dose conformality and/or delivery efficiency. Furthermore, SBRT is becoming increasingly important, which elevates the need for more efficient delivery, improved dose distribution. Here we will give an overview of our recent work in SPORT designed to harness the digital linacs and highlight the essential components of SPORT. We will summarize the pros and cons of traditional beamlet-based optimization (BBO) and direct aperture optimization (DAO) and introduce a new type of algorithm, compressed sensing (CS)-based inverse planning, that is capable of automatically removing the redundant segments during optimization and providing a plan with high deliverability in the presence of a large number of station control points (potentially non-coplanar, non-isocentric, and even multi-isocenters). We show that CS-approach takes the interplay between planning and delivery into account and allows us to balance the dose optimality and delivery efficiency in a controlled way and, providing a viable framework to address various unmet demands of the new generation linacs. A few specific implementation strategies of SPORT in the forms of fixed-gantry and rotational arc delivery are also presented.

  3. Formal Design Review Foot Clamp Modification

    International Nuclear Information System (INIS)

    OTEN, T.C.

    2000-01-01

    This report documents the Design Review performed for the foot clamp modification. The report documents the acceptability of the design, identifies the documents that were reviewed, the scope of the review and the members of the review team

  4. Molecular mechanism of DNA replication-coupled inactivation of the initiator protein in Escherichia coli: interaction of DnaA with the sliding clamp-loaded DNA and the sliding clamp-Hda complex.

    Science.gov (United States)

    Su'etsugu, Masayuki; Takata, Makoto; Kubota, Toshio; Matsuda, Yusaku; Katayama, Tsutomu

    2004-06-01

    In Escherichia coli, the ATP-DnaA protein initiates chromosomal replication. After the DNA polymerase III holoenzyme is loaded on to DNA, DnaA-bound ATP is hydrolysed in a manner depending on Hda protein and the DNA-loaded form of the DNA polymerase III sliding clamp subunit, which yields ADP-DnaA, an inactivated form for initiation. This regulatory DnaA-inactivation represses extra initiation events. In this study, in vitro replication intermediates and structured DNA mimicking replicational intermediates were first used to identify structural prerequisites in the process of DnaA-ATP hydrolysis. Unlike duplex DNA loaded with sliding clamps, primer RNA-DNA heteroduplexes loaded with clamps were not associated with DnaA-ATP hydrolysis, and duplex DNA provided in trans did not rescue this defect. At least 40-bp duplex DNA is competent for the DnaA-ATP hydrolysis when a single clamp was loaded. The DnaA-ATP hydrolysis was inhibited when ATP-DnaA was tightly bound to a DnaA box-bearing oligonucleotide. These results imply that the DnaA-ATP hydrolysis involves the direct interaction of ATP-DnaA with duplex DNA flanking the sliding clamp. Furthermore, Hda protein formed a stable complex with the sliding clamp. Based on these, we suggest a mechanical basis in the DnaA-inactivation that ATP-DnaA interacts with the Hda-clamp complex with the aid of DNA binding. Copyright Blackwell Publishing Limited

  5. Clamp wins pipe repair prize

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-04-01

    This paper describes the permanent pipeline repair system, developed by Tekmar, which is powered by seawater hydraulics and is easily installed and tested by any workclass remotely operated vehicle (rov). Details are given of the two main components of the system, namely, the diverless high pressure split repair clamp and the rov-operated tool to install it.

  6. A Hybrid Model for Safety Pharmacology on an Automated Patch Clamp Platform: Using Dynamic Clamp to Join iPSC-Derived Cardiomyocytes and Simulations of Ik1 Ion Channels in Real-Time

    Directory of Open Access Journals (Sweden)

    Birgit Goversen

    2018-01-01

    Full Text Available An important aspect of the Comprehensive In Vitro Proarrhythmia Assay (CiPA proposal is the use of human stem cell-derived cardiomyocytes and the confirmation of their predictive power in drug safety assays. The benefits of this cell source are clear; drugs can be tested in vitro on human cardiomyocytes, with patient-specific genotypes if needed, and differentiation efficiencies are generally excellent, resulting in a virtually limitless supply of cardiomyocytes. There are, however, several challenges that will have to be surmounted before successful establishment of hSC-CMs as an all-round predictive model for drug safety assays. An important factor is the relative electrophysiological immaturity of hSC-CMs, which limits arrhythmic responses to unsafe drugs that are pro-arrhythmic in humans. Potentially, immaturity may be improved functionally by creation of hybrid models, in which the dynamic clamp technique joins simulations of lacking cardiac ion channels (e.g., IK1 with hSC-CMs in real-time during patch clamp experiments. This approach has been used successfully in manual patch clamp experiments, but throughput is low. In this study, we combined dynamic clamp with automated patch clamp of iPSC-CMs in current clamp mode, and demonstrate that IK1 conductance can be added to iPSC-CMs on an automated patch clamp platform, resulting in an improved electrophysiological maturity.

  7. A High Step-Down Interleaved Buck Converter with Active-Clamp Circuits for Wind Turbines

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2012-12-01

    Full Text Available In this paper, a high step-down interleaved buck coupled-inductor converter (IBCC with active-clamp circuits for wind energy conversion has been studied. In high step-down voltage applications, an IBCC can extend duty ratio and reduce voltage stresses on active switches. In order to reduce switching losses of active switches to improve conversion efficiency, a IBCC with soft-switching techniques is usually required. Compared with passive-clamp circuits, the IBCC with active-clamp circuits have lower switching losses and minimum ringing voltage of the active switches. Thus, the proposed IBCC with active-clamp circuits for wind energy conversion can significantly increase conversion efficiency. Finally, a 240 W prototype of the proposed IBCC with active-clamp circuits was built and implemented. Experimental results have shown that efficiency can reach as high as 91%. The proposed IBCC with active-clamp circuits is presented in high step-down voltage applications to verify the performance and the feasibility for energy conversion of wind turbines.

  8. Natural Vibration Analysis of Clamped Rectangular Orthotropic Plates

    Science.gov (United States)

    dalaei, m.; kerr, a. d.

    The natural vibrations of clamped rectangular orthotropic plates are analyzed using the extended Kantorovich method. The developed iterative scheme converges very rapidly to the final result. The obtained natural frequencies are evaluated for a square plate made of Kevlar 49 Epoxy and the obtained results are compared with those published by Kanazawa and Kawai, and by Leissa. The agreement was found to be very close. As there are no exact analytical solutions for clamped rectangular plates, the generated closed form expression for the natural modes, and the corresponding natural frequencies, are very suitable for use in engineering analyses.

  9. Effect of non-ideal clamping shape on the resonance frequencies of silicon nanocantilevers

    Energy Technology Data Exchange (ETDEWEB)

    Guillon, Samuel; Saya, Daisuke; Mazenq, Laurent; Nicu, Liviu [CNRS, LAAS, 7 Avenue du Colonel Roche, F-31077 Toulouse Cedex 4 (France); Perisanu, Sorin; Vincent, Pascal [LPMCN, Universite Claude Bernard Lyon 1 et CNRS, 43 boulevard du 11 novembre 1918, 69622 Villeurbanne Cedex (France); Lazarus, Arnaud; Thomas, Olivier, E-mail: sguillon@laas.fr [Structural Mechanics and Coupled Systems Laboratory, Conservatoire National des Arts et Metiers, 2 rue Conte, 75003 Paris (France)

    2011-06-17

    In this paper, we investigate the effects of non-ideal clamping shapes on the dynamic behavior of silicon nanocantilevers. We fabricated silicon nanocantilevers using silicon on insulator (SOI) wafers by employing stepper ultraviolet (UV) lithography, which permits a resolution of under 100 nm. The nanocantilevers were driven by electrostatic force inside a scanning electron microscope (SEM). Both lateral and out-of-plane resonance frequencies were visually detected with the SEM. Next, we discuss overhanging of the cantilever support and curvature at the clamping point in the silicon nanocantilevers, which generally arises in the fabrication process. We found that the fundamental out-of-plane frequency of a realistically clamped cantilever is always lower than that for a perfectly clamped cantilever, and depends on the cantilever width and the geometry of the clamping point structure. Using simulation with the finite-elements method, we demonstrate that this discrepancy is attributed to the particular geometry of the clamping point (non-zero joining curvatures and a flexible overhanging) that is obtained in the fabrication process. The influence of the material orthotropy is also investigated and is shown to be negligible.

  10. Clamped end conditions and cross section deformation in the finite element absolute nodal coordinate formulation

    International Nuclear Information System (INIS)

    Hussein, Bassam A.; Weed, David; Shabana, Ahmed A.

    2009-01-01

    In the finite element absolute nodal coordinate formulation (ANCF), the elimination of the relative translations and rotations at a point does not necessarily define a fully clamped joint, particularly in the case of fully parameterized ANCF finite elements that allow for the deformation of the cross section. In this investigation, the formulations and results of two different sets of clamped end conditions that define two different joints are compared. The first joint, called the partially clamped joint, eliminates only the translations and rotations at a point on the cross section. The second joint, called the fully clamped joint, eliminates all the translation, rotation and deformation degrees of freedom at a point on the cross section. The kinematic equations that define the partially and fully clamped joints are developed, and the dynamic equations used in the comparative numerical study presented in this paper are shown. As discussed in this investigation, the fully clamped joint does not allow for the deformation of the cross section at the joint node since the gradient vectors remain orthogonal unit vectors. The partially clamped joint, on the other hand, allows for the deformation of the cross section. Nanson's formula is used as a measure of the deformation of the cross section in the case of the partially clamped joint. A very flexible pendulum that has a rigid body attached to its free end is used to compare the results of the partially and fully clamped joints. The numerical results obtained using this very flexible pendulum example show that, while the type of joint (partially or fully clamped) does not significantly affect the gross reference motion of the system, there are fundamental differences between the two joints since the partially clamped joint allows for the cross section deformations at the joint node

  11. Estimating end of life liabilities for plant licensing and financial planning for similarly configured stations

    International Nuclear Information System (INIS)

    Griffiths, G.; Kennard, J.

    2008-01-01

    Ontario Power Generation (OPG) is required to update estimated waste management and decommissioning costs on a 5-year cycle within the Canadian Nuclear Safety Commission's (CNSC) regulatory framework and provide a decommissioning cost update and provisions funds status to the Province of Ontario on a similar five-year cycle under the terms of the Ontario Nuclear Funds Agreement (ONFA). The following is an overview of the important steps used to develop OPG's nuclear power station decommissioning cost estimates, including a discussion of the responsibilities of both the owner (OPG) and estimating services vendor (TLG Services). This presentation is related to decommissioning estimating for multi-unit stations; therefore the discussion will be focused on identifying those activities that may be particularly impacted by multi-unit configuration or multiple stations. It should be noted that simultaneously developing decommissioning estimates for multiple multi-unit stations creates the opportunity to achieve economies of scale to more efficiently produce the estimates, and enables the owner and vendor to compare results between stations to identify inconsistencies. However, without careful attention to detail at the planning and execution stage, it also creates the potential liability of backtracking and developing the estimate multiple times, should significant assumptions be revised in mid-project. (authors)

  12. Estimating end of life liabilities for plant licensing and financial planning for similarly configured stations

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, G. [TLG Services, Inc. an Entergy Nuclear Co. (United States); Kennard, J. [Ontario Power Generation Inc. (Canada)

    2008-07-01

    Ontario Power Generation (OPG) is required to update estimated waste management and decommissioning costs on a 5-year cycle within the Canadian Nuclear Safety Commission's (CNSC) regulatory framework and provide a decommissioning cost update and provisions funds status to the Province of Ontario on a similar five-year cycle under the terms of the Ontario Nuclear Funds Agreement (ONFA). The following is an overview of the important steps used to develop OPG's nuclear power station decommissioning cost estimates, including a discussion of the responsibilities of both the owner (OPG) and estimating services vendor (TLG Services). This presentation is related to decommissioning estimating for multi-unit stations; therefore the discussion will be focused on identifying those activities that may be particularly impacted by multi-unit configuration or multiple stations. It should be noted that simultaneously developing decommissioning estimates for multiple multi-unit stations creates the opportunity to achieve economies of scale to more efficiently produce the estimates, and enables the owner and vendor to compare results between stations to identify inconsistencies. However, without careful attention to detail at the planning and execution stage, it also creates the potential liability of backtracking and developing the estimate multiple times, should significant assumptions be revised in mid-project. (authors)

  13. Role of the Checkpoint Clamp in DNA Damage Response

    Directory of Open Access Journals (Sweden)

    Mihoko Kai

    2013-01-01

    Full Text Available DNA damage occurs during DNA replication, spontaneous chemical reactions, and assaults by external or metabolism-derived agents. Therefore, all living cells must constantly contend with DNA damage. Cells protect themselves from these genotoxic stresses by activating the DNA damage checkpoint and DNA repair pathways. Coordination of these pathways requires tight regulation in order to prevent genomic instability. The checkpoint clamp complex consists of Rad9, Rad1 and Hus1 proteins, and is often called the 9-1-1 complex. This PCNA (proliferating cell nuclear antigen-like donut-shaped protein complex is a checkpoint sensor protein that is recruited to DNA damage sites during the early stage of the response, and is required for checkpoint activation. As PCNA is required for multiple pathways of DNA metabolism, the checkpoint clamp has also been implicated in direct roles in DNA repair, as well as in coordination of the pathways. Here we discuss roles of the checkpoint clamp in DNA damage response (DDR.

  14. Three-dimensional renal CT angiography for guiding segmental renal artery clamping during laparoscopic partial nephrectomy

    International Nuclear Information System (INIS)

    Xu, Yi; Shao, Pengfei; Zhu, Xiaomei; Lv, Qiang; Liu, Wangyan; Xu, Hai; Zhu, Yinsu; Yang, Guangyu; Tang, Lijun; Yin, Changjun

    2013-01-01

    Aim: To evaluate the effectiveness of three-dimensional (3D) renal computed tomography angiography (CTA) in guiding segmental renal artery clamping during laparoscopic partial nephrectomy (LPN). Materials and methods: Forty-three patients with renal tumours undergoing renal CTA before LPN were retrospectively enrolled in this study. 3D arteriogram reconstructed images were created to identify the renal tumour-supplying arteries. The number and location of these targeted vessels were annotated on 3D images preoperatively and compared with the clamped vessels during LPN. The consistency between target vessels annotated at CTA and clamped arteries at LPN was compared both using a patient-based analysis and vessel-based analysis. The χ 2 test was applied to analyse the influence of tumour size, location, and growth pattern on the number of clamped segmental renal branches. Results: On patient-based analysis, the number of targeted vessels was consistent with the clamped vessels during LPN in 33 of 43 patients. On vessel-based analysis, 56 of 65 target vessels annotated at CTA were clamped during LPN. More segmental renal branches (p = 0.04) were clamped in patients with tumours of larger size. Tumour location and growth pattern had no association with the number of clamped segmental branches during LPN. Conclusion: High-quality CTA images and 3D reconstruction images can detect detailed information of tumour-supplying arteries to renal tumours. 3D renal CTA is an effective way to guide segmental renal artery clamping during LPN

  15. Implementation of a fast 16-Bit dynamic clamp using LabVIEW-RT.

    Science.gov (United States)

    Kullmann, Paul H M; Wheeler, Diek W; Beacom, Joshua; Horn, John P

    2004-01-01

    The dynamic-clamp method provides a powerful electrophysiological tool for creating virtual ionic conductances in living cells and studying their influence on membrane potential. Here we describe G-clamp, a new way to implement a dynamic clamp using the real-time version of the Lab-VIEW programming environment together with a Windows host, an embedded microprocessor that runs a real-time operating system and a multifunction data-acquisition board. The software includes descriptions of a fast voltage-dependent sodium conductance, delayed rectifier, M-type and A-type potassium conductances, and a leak conductance. The system can also read synaptic conductance waveforms from preassembled data files. These virtual conductances can be reliably implemented at speeds < or =43 kHz while simultaneously saving two channels of data with 16-bit precision. G-clamp also includes utilities for measuring current-voltage relations, synaptic strength, and synaptic gain. Taking an approach built on a commercially available software/hardware platform has resulted in a system that is easy to assemble and upgrade. In addition, the graphical programming structure of LabVIEW should make it relatively easy for others to adapt G-clamp for new experimental applications.

  16. Fluid Physical and Transport Phenomena Studies aboard the International Space Station: Planned Experiments

    Science.gov (United States)

    Singh, Bhim S.

    1999-01-01

    This paper provides an overview of the microgravity fluid physics and transport phenomena experiments planned for the International Spare Station. NASA's Office of Life and Microgravity Science and Applications has established a world-class research program in fluid physics and transport phenomena. This program combines the vast expertise of the world research community with NASA's unique microgravity facilities with the objectives of gaining new insight into fluid phenomena by removing the confounding effect of gravity. Due to its criticality to many terrestrial and space-based processes and phenomena, fluid physics and transport phenomena play a central role in the NASA's Microgravity Program. Through widely publicized research announcement and well established peer-reviews, the program has been able to attract a number of world-class researchers and acquired a critical mass of investigations that is now adding rapidly to this field. Currently there arc a total of 106 ground-based and 20 candidate flight principal investigators conducting research in four major thrust areas in the program: complex flows, multiphase flow and phase change, interfacial phenomena, and dynamics and instabilities. The International Space Station (ISS) to be launched in 1998, provides the microgravity research community with a unprecedented opportunity to conduct long-duration microgravity experiments which can be controlled and operated from the Principal Investigators' own laboratory. Frequent planned shuttle flights to the Station will provide opportunities to conduct many more experiments than were previously possible. NASA Lewis Research Center is in the process of designing a Fluids and Combustion Facility (FCF) to be located in the Laboratory Module of the ISS that will not only accommodate multiple users but, allow a broad range of fluid physics and transport phenomena experiments to be conducted in a cost effective manner.

  17. Locoregional Anesthesia for Carotid Endarterectomy: Identification of Patients with Intolerance to Cross-Clamping.

    Science.gov (United States)

    Dellaretti, Marcos; de Vasconcelos, Laura T; Dourado, Jules; de Souza, Renata F; Fontoura, Renato R; de Sousa, Atos A

    2016-03-01

    During carotid endarterectomy (CEA), carotid cross-clamping is performed to allow for artery incision and plaque removal. A small subgroup of patients can tolerate carotid occlusion for only a few seconds, if at all, without presenting neurologic deficit. These patients are described as having ''cross-clamp intolerance.'' The purpose of this study was to demonstrate the safety of locoregional anesthesia in identifying patients with cross-clamp intolerance and factors associated with this condition. From August 2008 to May 2010, 115 consecutive patients were submitted to CEA under locoregional anesthesia at the Santa Casa de Belo Horizonte; the procedure was performed by the main author. Patients who showed intolerance to internal carotid artery (ICA) occlusion for intolerance. Among the 115 participating patients, 9.6% (11 patients) showed intolerance to ICA occlusion and developed deficits in intolerance). The factor that was associated with cross-clamp intolerance was the mean degree of contralateral carotid stenosis, which was 57.5% for those who presented intolerance and 27.8% for those who tolerated ICA occlusion. Locoregional anesthesia is a safe method for identifying patients with cross-clamp intolerance. Patients with cross-clamp intolerance present contralateral stenosis that is greater on average than patients who readily tolerate carotid artery occlusion. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Artifactual voltage response recorded from hair cells with patch-clamp amplifiers.

    Science.gov (United States)

    Masetto, S; Weng, T; Valli, P; Correia, M J

    1999-06-23

    Patch-clamp amplifiers (PCAs) are commonly used to characterize voltage- and current-clamp responses in the same cell. However, the cell membrane voltage response can be severely distorted by PCAs working in the current-clamp mode. Here we compare the voltage response of pigeon semicircular canal hair cells in situ, recorded with two different PCAs, and with a classic microelectrode bridge amplifier (BA). We found that the voltage response of hair cells recorded with PCAs differed significantly from that recorded with the BA. The true hair cell membrane voltage response to positive current steps was characterized by a strongly damped oscillation, whose frequency and duration depended on hair cell location in the sensory crista ampullaris.

  19. Dynamic assembly of Hda and the sliding clamp in the regulation of replication licensing.

    Science.gov (United States)

    Kim, Jin S; Nanfara, Michael T; Chodavarapu, Sundari; Jin, Kyeong S; Babu, Vignesh M P; Ghazy, Mohamed A; Chung, Scisung; Kaguni, Jon M; Sutton, Mark D; Cho, Yunje

    2017-04-20

    Regulatory inactivation of DnaA (RIDA) is one of the major regulatory mechanisms of prokaryotic replication licensing. In RIDA, the Hda-sliding clamp complex loaded onto DNA directly interacts with adenosine triphosphate (ATP)-bound DnaA and stimulates the hydrolysis of ATP to inactivate DnaA. A prediction is that the activity of Hda is tightly controlled to ensure that replication initiation occurs only once per cell cycle. Here, we determined the crystal structure of the Hda-β clamp complex. This complex contains two pairs of Hda dimers sandwiched between two β clamp rings to form an octamer that is stabilized by three discrete interfaces. Two separate surfaces of Hda make contact with the β clamp, which is essential for Hda function in RIDA. The third interface between Hda monomers occludes the active site arginine finger, blocking its access to DnaA. Taken together, our structural and mutational analyses of the Hda-β clamp complex indicate that the interaction of the β clamp with Hda controls the ability of Hda to interact with DnaA. In the octameric Hda-β clamp complex, the inability of Hda to interact with DnaA is a novel mechanism that may regulate Hda function. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  20. The Effect of an Added Mass on the Frequency Shifts of a Clamped-Clamped Microbeam for Bio-Mass Detection

    KAUST Repository

    Bouchaala, Adam M.

    2016-12-05

    We present analytical formulations to calculate the induced resonance frequency shifts of electrically actuated clamped-clamped microbeams due to an added mass. Based on the Euler-Bernoulli beam theory, we investigate the linear dynamic responses of the beams added masses, which are modeled as discrete point masses. Analytical expressions based on perturbation techniques and a one-mode Galerkin approximation are developed to calculate accurately the frequency shifts under a DC voltage as a function of the added mass and position. The analytical results are compared to numerical solution of the eigenvalue problem. Results are shown for the fundamental as well as the higher-order modes of the beams. The results indicate a significant increase in the frequency shift, and hence the sensitivity of detection, when scaling down to nano scale and using higher-order modes.

  1. The Effect of an Added Mass on the Frequency Shifts of a Clamped-Clamped Microbeam for Bio-Mass Detection

    KAUST Repository

    Bouchaala, Adam M.; Nayfeh, Ali H.; Younis, Mohammad I.

    2016-01-01

    We present analytical formulations to calculate the induced resonance frequency shifts of electrically actuated clamped-clamped microbeams due to an added mass. Based on the Euler-Bernoulli beam theory, we investigate the linear dynamic responses of the beams added masses, which are modeled as discrete point masses. Analytical expressions based on perturbation techniques and a one-mode Galerkin approximation are developed to calculate accurately the frequency shifts under a DC voltage as a function of the added mass and position. The analytical results are compared to numerical solution of the eigenvalue problem. Results are shown for the fundamental as well as the higher-order modes of the beams. The results indicate a significant increase in the frequency shift, and hence the sensitivity of detection, when scaling down to nano scale and using higher-order modes.

  2. Early identification of hERG liability in drug discovery programs by automated patch clamp

    Directory of Open Access Journals (Sweden)

    Timm eDanker

    2014-09-01

    Full Text Available Blockade of the cardiac ion channel coded by hERG can lead to cardiac arrhythmia, which has become a major concern in drug discovery and development. Automated electrophysiological patch clamp allows assessment of hERG channel effects early in drug development to aid medicinal chemistry programs and has become routine in pharmaceutical companies. However, a number of potential sources of errors in setting up hERG channel assays by automated patch clamp can lead to misinterpretation of data or false effects being reported. This article describes protocols for automated electrophysiology screening of compound effects on the hERG channel current. Protocol details and the translation of criteria known from manual patch clamp experiments to automated patch clamp experiments to achieve good quality data are emphasized. Typical pitfalls and artifacts that may lead to misinterpretation of data are discussed. While this article focuses on hERG channel recordings using the QPatch (Sophion A/S, Copenhagen, Denmark technology, many of the assay and protocol details given in this article can be transferred for setting up different ion channel assays by automated patch clamp and are similar on other planar patch clamp platforms.

  3. Finite element analysis on factors influencing the clamping force in an electrostatic chuck

    International Nuclear Information System (INIS)

    Wang Xingkuo; Yang Yiyong; Cheng Jia; Wang Kesheng; Sun Yuchun; Cao Minglu; Ji Linhong

    2014-01-01

    As one of the core components of IC manufacturing equipment, the electrostatic chuck (ESC) has been widely applied in semiconductor processing such as etching, PVD and CVD. The clamping force of the ESC is one of the most important technical indicators. A multi-physics simulation software COMSOL is used to analyze the factors influencing the clamping force. The curves between the clamping force and the main parameters such as DC voltage, electrode thickness, electrode radius, dielectric thickness and helium gap are obtained. Moreover, the effects of these factors on the clamping force are investigated by means of orthogonal experiments. The results show that the factors can be ranked in order of voltage, electrode radius, helium gap and dielectric thickness according to their importance, which may offer certain reference for the design of ESCs. (semiconductor devices)

  4. Estimating the Cost of Early Infant Male Circumcision in Zimbabwe: Results From a Randomized Noninferiority Trial of AccuCirc Device Versus Mogen Clamp

    Science.gov (United States)

    Mavhu, Webster; Hatzold, Karin; Biddle, Andrea K.; Madidi, Ngonidzashe; Ncube, Getrude; Mugurungi, Owen; Ticklay, Ismail; Cowan, Frances M.; Thirumurthy, Harsha

    2015-01-01

    Background: Safe and cost-effective programs for implementing early infant male circumcision (EIMC) in Africa need to be piloted. We present results on a relative cost analysis within a randomized noninferiority trial of EIMC comparing the AccuCirc device with Mogen clamp in Zimbabwe. Methods: Between January and June 2013, male infants who met inclusion criteria were randomized to EIMC through either AccuCirc or Mogen clamp conducted by a doctor, using a 2:1 allocation ratio. We evaluated the overall unit cost plus the key cost drivers of EIMC using both AccuCirc and Mogen clamp. Direct costs included consumable and nonconsumable supplies, device, personnel, associated staff training, and environmental costs. Indirect costs comprised capital and support personnel costs. In 1-way sensitivity analyses, we assessed potential changes in unit costs due to variations in main parameters, one at a time, holding all other values constant. Results: The unit costs of EIMC using AccuCirc and Mogen clamp were $49.53 and $55.93, respectively. Key cost drivers were consumable supplies, capacity utilization, personnel costs, and device price. Unit prices are likely to be lowest at full capacity utilization and increase as capacity utilization decreases. Unit prices also fall with lower personnel salaries and increase with higher device prices. Conclusions: EIMC has a lower unit cost when using AccuCirc compared with Mogen clamp. To minimize unit costs, countries planning to scale-up EIMC using AccuCirc need to control costs of consumables and personnel. There is also need to negotiate a reasonable device price and maximize capacity utilization. PMID:26017658

  5. Estimating the Cost of Early Infant Male Circumcision in Zimbabwe: Results From a Randomized Noninferiority Trial of AccuCirc Device Versus Mogen Clamp.

    Science.gov (United States)

    Mangenah, Collin; Mavhu, Webster; Hatzold, Karin; Biddle, Andrea K; Madidi, Ngonidzashe; Ncube, Getrude; Mugurungi, Owen; Ticklay, Ismail; Cowan, Frances M; Thirumurthy, Harsha

    2015-08-15

    Safe and cost-effective programs for implementing early infant male circumcision (EIMC) in Africa need to be piloted. We present results on a relative cost analysis within a randomized noninferiority trial of EIMC comparing the AccuCirc device with Mogen clamp in Zimbabwe. Between January and June 2013, male infants who met inclusion criteria were randomized to EIMC through either AccuCirc or Mogen clamp conducted by a doctor, using a 2:1 allocation ratio. We evaluated the overall unit cost plus the key cost drivers of EIMC using both AccuCirc and Mogen clamp. Direct costs included consumable and nonconsumable supplies, device, personnel, associated staff training, and environmental costs. Indirect costs comprised capital and support personnel costs. In 1-way sensitivity analyses, we assessed potential changes in unit costs due to variations in main parameters, one at a time, holding all other values constant. The unit costs of EIMC using AccuCirc and Mogen clamp were $49.53 and $55.93, respectively. Key cost drivers were consumable supplies, capacity utilization, personnel costs, and device price. Unit prices are likely to be lowest at full capacity utilization and increase as capacity utilization decreases. Unit prices also fall with lower personnel salaries and increase with higher device prices. EIMC has a lower unit cost when using AccuCirc compared with Mogen clamp. To minimize unit costs, countries planning to scale-up EIMC using AccuCirc need to control costs of consumables and personnel. There is also need to negotiate a reasonable device price and maximize capacity utilization.

  6. Modelling the clamping force distribution among chips in press-pack IGBTs using the finite element method

    DEFF Research Database (Denmark)

    Hasmasan, Adrian Augustin; Busca, Christian; Teodorescu, Remus

    2012-01-01

    In this paper, a FEM (finite element method) based mechanical model for PP (press-pack) IGBTs (insulated gate bipolar transistors) is presented, which can be used to calculate the clamping force distribution among chips under various clamping conditions. The clamping force is an important parameter...... for the chip, because it influences contact electrical resistance, contact thermal resistance and power cycling capability. Ideally, the clamping force should be equally distributed among chips, in order to maximize the reliability of the PP IGBT. The model is built around a hypothetical PP IGBT with 9 chips......, and it has numerous simplifications in order to reduce the simulation time as much as possible. The developed model is used to analyze the clamping force distribution among chips, in various study cases, where uniform and non-uniform clamping pressures are applied on the studied PP IGBT....

  7. Radiological mapping of emergency planning zone of Narora Atomic Power Station

    International Nuclear Information System (INIS)

    Pujari, R.N.; Saindane, Shashank; Narsaiah, M.V.R.; Solase, S.S.; Chaudbury, Probal; Kumar, Deepak; Gautam, Y.P.; Sharma, A.K.; Kumar, Avinash

    2016-01-01

    As a part of emergency preparedness programme, environmental radiation monitoring of Emergency Planning Zone (EPZ) (16 km radius) of Nuclear Power Plants (NPPs) is being carried out periodically. An environmental radiation monitoring of EPZ of Narora Atomic Power Station (NAPS) was carried out by installing various state-of-the-art mobile radiation monitoring systems in a vehicle and soil samples were collected from 40 locations. Around 200 important villages within EPZ were monitored and the radiological mapping of the monitored area is shown. The average dose rate recorded was 125 ± 28.8 nGy h -1 . Analysis of the collected dose rate data and the soil samples indicate normal background radiation level in the area

  8. An isolated Hda-clamp complex is functional in the regulatory inactivation of DnaA and DNA replication.

    Science.gov (United States)

    Kawakami, Hironori; Su'etsugu, Masayuki; Katayama, Tsutomu

    2006-10-01

    In Escherichia coli, a complex consisting of Hda and the DNA-loaded clamp-subunit of the DNA polymerase III holoenzyme promotes hydrolysis of DnaA-ATP. The resultant ADP-DnaA is inactive for initiation of chromosomal DNA replication, thereby repressing excessive initiations. As the cellular content of the clamp is 10-100 times higher than that of Hda, most Hda molecules might be complexed with the clamp in vivo. Although Hda predominantly forms irregular aggregates when overexpressed, in the present study we found that co-overexpression of the clamp with Hda enhances Hda solubility dramatically and we efficiently isolated the Hda-clamp complex. A single molecule of the complex appears to consist of two Hda molecules and a single clamp. The complex is competent in DnaA-ATP hydrolysis and DNA replication in the presence of DNA and the clamp deficient subassembly of the DNA polymerase III holoenzyme (pol III*). These findings indicate that the clamp contained in the complex is loaded onto DNA through an interaction with the pol III* and that the Hda activity is preserved in these processes. The complex consisting of Hda and the DNA-unloaded clamp may play a specific role in a process proceeding to the DnaA-ATP hydrolysis in vivo.

  9. Patch Clamp: A Powerful Technique for Studying the Mechanism of Acupuncture

    Directory of Open Access Journals (Sweden)

    D. Zhang

    2012-01-01

    Full Text Available Cellular and molecular events can be investigated using electrophysiological techniques. In particular, the patch-clamp method provides detailed information. In addition, the patch-clamp technique has become a powerful method for investigating the mechanisms underlying the effects of acupuncture. In this paper, recent researches on how acupuncture might modulate electrophysiological responses in the central nervous system (CNS and affect peripheral structures are reviewed.

  10. Prediction of clamp-derived insulin sensitivity from the oral glucose insulin sensitivity index

    DEFF Research Database (Denmark)

    Tura, Andrea; Chemello, Gaetano; Szendroedi, Julia

    2018-01-01

    that underwent both a clamp and an OGTT or meal test, thereby allowing calculation of both the M value and OGIS. The population was divided into a training and a validation cohort (n = 359 and n = 154, respectively). After a stepwise selection approach, the best model for M value prediction was applied......AIMS/HYPOTHESIS: The euglycaemic-hyperinsulinaemic clamp is the gold-standard method for measuring insulin sensitivity, but is less suitable for large clinical trials. Thus, several indices have been developed for evaluating insulin sensitivity from the oral glucose tolerance test (OGTT). However......, most of them yield values different from those obtained by the clamp method. The aim of this study was to develop a new index to predict clamp-derived insulin sensitivity (M value) from the OGTT-derived oral glucose insulin sensitivity index (OGIS). METHODS: We analysed datasets of people...

  11. Common voltage eliminating of SVM diode clamping three-level inverter connected to grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    A novel method of common voltage eliminating is put forward for SVM diode clamping three-level inverter connected to grid by calculation of common voltage of its various switching states. PLECS is used to model this three-level inverter connected to grid and good results are obtained. First...... analysis of common mode voltage for switching states of diode clamping 3-level inverter is given in detail. Second the common mode voltage eliminating control strategy of SVM is described for diode clamping three-level inverter. Third, PLECS is briefly introduced. Fourth, the modeling of diode clamping...... three-level inverter is presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS is a very powerful tool to real power circuits modeling. They have also verified that proposed common mode voltage eliminating control strategy of SVM is feasible...

  12. Investigation on the Behavior of the Jointing Clamps to the Simulated Environmental - LOCA

    International Nuclear Information System (INIS)

    Ivan, P.; Segarceanu, D.; Geambasu, C.

    2002-01-01

    The paper presents the main aspect concerning the electric parameter variation of jointing clamps operating under specific environmental conditions determinate by pressure, temperature and humidity. The testing of jointing clamps capability to meet and exceed the required performances all along its operating life implies the performing of LOCA simulation conditions while the jointing clamps is bright in a relatively short time under conditions equivalent to those at the end of its service life. The paper describes ageing and measurement techniques and the analyses of electric parameter behaviour in these environmental simulated conditions. (author)

  13. Research on micromanipulator’s clamping force sensing based on static wirerope tension of a surgical robot

    Directory of Open Access Journals (Sweden)

    Lingtao Yu

    2015-04-01

    Full Text Available The micromanipulator’s force feedback is one of the key research contents of minimally invasive surgical robotic system. Because the micromanipulator is a kind of compact construction which is suitable for valve installation with small space in surgery, especially for the influence of disinfection method, there are major difficulties and limitations to integrate compact sensors in the end of micromanipulator. This article focuses on the 3-degree-of-freedom micromanipulator’s clamping force sensing, and these three joints are actuated by wirerope driving. A clamping force sensing method is proposed based on static tension of wirerope driving, and a static model between the clamping force and wirerope’s static tension is established considering the influence of real friction resistance in the mechanical system. Finally, an equivalent experimental test platform for 3-degree-of-freedom micromanipulator’s clamping force sensing is set up, and then a series of experiments of the clamping force are studied. The frictional resistances of wirerope between the guide plate and guide pulley mechanism are tested, and a calibration and correction method of the experimental clamping force is proposed. The final experiment results show that the total average accuracy of experimental clamping force is about 78.3%, and it can be the basic measurement force to realize micromanipulator’s clamping force feedback of a minimally invasive surgical robot.

  14. The Space Station Photovoltaic Panels Plasma Interaction Test Program: Test plan and results

    Science.gov (United States)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1989-01-01

    The Plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  15. The Space Station photovoltaic panels plasma interaction test program - Test plan and results

    Science.gov (United States)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1990-01-01

    The plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  16. Clamp and Gas Nozzle for TIG Welding

    Science.gov (United States)

    Gue, G. B.; Goller, H. L.

    1982-01-01

    Tool that combines clamp with gas nozzle is aid to tungsten/inert-gas (TIG) welding in hard-to-reach spots. Tool holds work to be welded while directing a stream of argon gas at weld joint, providing an oxygen-free environment for tungsten-arc welding.

  17. The Anion Paradox in Sodium Taste Reception: Resolution by Voltage-Clamp Studies

    Science.gov (United States)

    Ye, Qing; Heck, Gerard L.; Desimone, John A.

    1991-11-01

    Sodium salts are potent taste stimuli, but their effectiveness is markedly dependent on the anion, with chloride yielding the greatest response. The cellular mechanisms that mediate this phenomenon are not known. This "anion paradox" has been resolved by considering the field potential that is generated by restricted electrodiffusion of the anion through paracellular shunts between taste-bud cells. Neural responses to sodium chloride, sodium acetate, and sodium gluconate were studied while the field potential was voltage-clamped. Clamping at electronegative values eliminated the anion effect, whereas clamping at electropositive potentials exaggerated it. Thus, field potentials across the lingual epithelium modulate taste reception, indicating that the functional unit of taste reception includes the taste cell and its paracellular microenvironment.

  18. Space Station - Opportunity for international cooperation and utilization

    Science.gov (United States)

    Pedersen, K. S.

    1984-01-01

    In connection with his announcement regarding the development of a permanently manned Space Station, President Reagan invited the United States' friends and allies to join in the Space Station program. The President's invitation was preceded by more than two years of interaction between NASA and some of its potential partners in Space Station planning activities. Attention is given to international participation in Space Station planning, international cooperation on the Space Station, the guidelines for international cooperation, and the key challenges. Questions regarding quid pro quos are considered along with aspects of technology transfer, commercial use, problems of management, and the next steps concerning the Space Station program.

  19. Timing of umbilical cord-clamping and infant anaemia: the role of maternal anaemia.

    Science.gov (United States)

    Blouin, Brittany; Penny, Mary E; Maheu-Giroux, Mathieu; Casapía, Martín; Aguilar, Eder; Silva, Hermánn; Creed-Kanashiro, Hilary M; Joseph, Serene A; Gagnon, Anita; Rahme, Elham; Gyorkos, Theresa W

    2013-05-01

    Evidence from randomized controlled trials has shown that delayed cord-clamping is beneficial to infant iron status. The role of maternal anaemia in this relationship, however, has not been established. To determine the effect of maternal anaemia at delivery on the association between timing of umbilical cord-clamping and infant anaemia at 4 and 8 months of age. A cohort of pregnant women admitted to the labour room of Hospital Iquitos (Iquitos, Peru) and their newborns were recruited into the study during two time periods (18 May to 3 June and 6-20 July 2009). Between the two recruitment periods, the hospital's policy changed from early to delayed umbilical cord-clamping. Maternal haemoglobin levels were measured before delivery, and the time between delivery and cord-clamping was recorded at delivery for the entire cohort. Mother-infant pairs were followed-up at 4 (n = 207) and 8 months (n = 184) post partum. Infant haemoglobin levels were measured at follow-up visits. Data were analysed using logistic regression models. The prevalence of maternal anaemia (Hb anaemia was modified by the mother's anaemia status. Significant benefits of delayed cord-clamping in preventing anaemia were found in infants born to anaemic mothers at both 4 months (aOR = 0.59, 95% CI 0.36-0.99) and 8 months (aOR = 0.38, 95% CI 0.19-0.76) of age. The study contributes additional evidence in support of delayed cord-clamping. This intervention is likely to have most public health impact in areas with a high prevalence of anaemia during pregnancy.

  20. Enhancing endogenous stem cells in the newbornvia delayed umbilical cord clamping

    Institute of Scientific and Technical Information of China (English)

    Christopher Lawton; Sandra Acosta; Nate Watson; Chiara Gonzales-Portillo; hTeo Diamandis; Naoki Tajiri; Yuji Kaneko; Paul R. Sanberg; Cesar V. Borlongan

    2015-01-01

    There is currently no consensus among clinicians and scientists over the appropriate or optimal timing for umbilical cord clamping. However, many clinical studies have suggested that delayed cord clamping is associated with various neonatal beneifts including increased blood volume, reduced need for blood transfusion, increased cerebral oxygenation in pre-term infants, and decreased frequency of iron deifciency anemia in term infants. Human umbilical cord blood con-tains signiifcant amounts of stem and progenitor cells and is currently used in the treatment of several life-threatening diseases. We propose that delayed cord clamping be encouraged as it en-hances blood lfow from the placenta to the neonate, which is accompanied by an increase supply of valuable stem and progenitor cells, as well as may improve blood oxygenation and increase blood volume, altogether reducing the infant’s susceptibility to both neonatal and age-related diseases.

  1. Clampe de Ganz no tratamento de urgência em lesões do anel pélvico Ganz clamps to treat emergencies in pelvic ring lesions

    Directory of Open Access Journals (Sweden)

    Gilberto José Cação Pereira

    2008-07-01

    Full Text Available OBJETIVO: Avaliar a eficiência do clampe de Ganz na estabilização e redução dos deslocamentos da pelve, quando utilizado no tratamento de urgência, além de aquilatar eventuais dificuldades e facilidades do método. MÉTODOS: O clampe de Ganz foi utilizado no tratamento de urgência em 31 pacientes com graves lesões do anel pélvico (Tile C associadas a importante instabilidade hemodinâmica. RESULTADO: Entre os pacientes, 27 (87,1% apresentaram evolução favorável, com estabilização, redução dos deslocamentos e compressão da região posterior do anel, além de estabilização hemodinâmica, e quatro (12,9% evoluíram para óbito. CONCLUSÃO: O clampe de Ganz mostrou-se eficiente ferramenta no tratamento de urgência das lesões do anel pélvico, por ser de concepção simples, de rápida colocação, não impedir ou dificultar procedimentos no abdome e, principalmente, por permitir a estabilização da pelve, redução dos deslocamentos e compressão na região posterior do anel, local onde ocorrem os maiores sangramentos, reduzindo-os ou eliminando-os.OBJECTIVE: To evaluate the effectiveness of Ganz clamp to stabilize and reduce pelvic dislocations in emergency situations, and to assess possible difficult and easy aspects of the method. METHOD: Ganz clamp was used in the emergency treatment of 31 patients with severe lesions of the pelvic ring (Tile C associated to major hemodynamic instability. RESULTS: Among the patients, 27 (87.1% presented a favorable evolution, with stabilization, reduction of dislocations, and compression of the posterior portion of the ring, and also hemodynamic stabilization, and 4 (12.9% died. CONCLUSION: The Ganz clamp was found to be an effective tool in the emergency treatment of pelvic ring lesions because it has an uncomplicated conception, allowing for a fast placement, because it does not prevent nor make it difficult for abdominal procedures, and most of all because it allows for the

  2. Evaluation of Introduction of a Delayed Cord Clamping Protocol for Premature Neonates in a High-Volume Maternity Center.

    Science.gov (United States)

    Liu, Lilly Y; Feinglass, Joe M; Khan, Janine Y; Gerber, Susan E; Grobman, William A; Yee, Lynn M

    2017-05-01

    To evaluate adherence to a delayed cord clamping protocol for preterm births in the first 2 years after its introduction, perform a quality improvement assessment, and determine neonatal outcomes associated with protocol implementation and adherence. This is a retrospective cohort study of women delivering singleton neonates at 23-32 weeks of gestation in the 2 years before (preprotocol) and 2 years after (postprotocol) introduction of a 30-second delayed cord clamping protocol at a large-volume academic center. This policy was communicated to obstetric and pediatric health care providers and nurses and reinforced with intermittent educational reviews. Barriers to receiving delayed cord clamping were assessed using χ tests and multivariable logistic regression. Neonatal outcomes then were compared between all neonates in the preprotocol period and all neonates in the postprotocol period and between all neonates in the preprotocol period and neonates receiving delayed cord clamping in the postprotocol period using multivariable linear and logistic regression analyses. Of the 427 eligible neonates, 187 were born postprotocol. Of these, 53.5% (n=100) neonates received delayed cord clamping according to the protocol. The rate of delayed cord clamping preprotocol was 0%. Protocol uptake and frequency of delayed cord clamping increased over the 2 years after its introduction. In the postprotocol period, cesarean delivery was the only factor independently associated with failing to receive delayed cord clamping (adjusted odds ratio [OR] 0.49, 95% confidence interval [CI] 0.25-0.96). In comparison with the preprotocol period, those who received delayed cord clamping in the postprotocol period had significantly higher birth hematocrit (β=2.46, P=.007) and fewer blood transfusions in the first week of life (adjusted OR 0.49, 95% CI 0.25-0.96). After introduction of an institutional delayed cord clamping protocol followed by continued health care provider education and

  3. The regulatory approach to ensuring the adequacy of emergency planning for nuclear power stations in South Africa

    International Nuclear Information System (INIS)

    Metcalf, P.E.

    1986-01-01

    The first nuclear power station in South Africa became operational in 1984. The paper describes the basis on which emergency planning was required from a regulatory point of view. The extent of planning required and the associated facilities are described, together with the structure of the emergency response organization and associated responsibilities. The provisions in place to ensure ongoing readiness of the emergency response organization are discussed. These include training and retraining of operational staff, equipment and inventory checks and the conducting of an annual full-scale demonstration exercise. (author)

  4. Higher order modes excitation of electrostatically actuated clamped–clamped microbeams: experimental and analytical investigation

    KAUST Repository

    Jaber, Nizar; Ramini, Abdallah; Carreno, Armando Arpys Arevalo; Younis, Mohammad I.

    2016-01-01

    © 2016 IOP Publishing Ltd. In this study, we demonstrate analytically and experimentally the excitations of the higher order modes of vibrations in electrostatically actuated clamped-clamped microbeam resonators. The concept is based on using

  5. 21 CFR 882.5175 - Carotid artery clamp.

    Science.gov (United States)

    2010-04-01

    ... (the principal artery in the neck that supplies blood to the brain) and has a removable adjusting mechanism that protrudes through the skin of the patient's neck. The clamp is used to occlude the patient's... Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...

  6. Analysis and testing of the DIII-D ohmic heating coil lead repair clamp

    International Nuclear Information System (INIS)

    Reis, E.E.; Anderson, P.M.; Chin, E.; Robinson, J.I.

    1997-11-01

    DIII-D has been operating for the last year with limited volt-second capabilities due to structural failure of a conductor lead to one of the ohmic heating (OH) solenoids. The conductor failure was due to poor epoxy impregnation of the overwrap of the lead pack, resulting in copper fatigue and a water leak. A number of structural analyses were performed to assist in determining the failure scenario and to evaluate various repair options. A fatigue stress analysis of the leads with a failed epoxy overwrap indicated crack initiation after 1,000 cycles at the maximum operating conditions. The failure occurred in a very inaccessible area which restricted design repair options to concepts which could be implemented remotely. Several design options were considered for repairing the lead so that it can sustain the loads for 7.5 Vs conditions at full toroidal field. A clamp, along with preloaded banding straps and shim bags, provides a system that guarantees that the stress at the crack location is always compressive and prevents further crack growth in the conductor. Due to the limited space available for the repair, it was necessary to design the clamp system to operate at the material yield stress. The primary components of the clamp system were verified by load tests prior to installation. The main body of the clamp contains a load cell and potentiometer for monitoring the load-deflection characteristics of the clamp and conductors during plasma operation. Strain gages provides redundant instrumentation. If required, the preload on the conductors can be increased remotely by a special wrench attached to the clamp assembly

  7. Ventilation before Umbilical Cord Clamping improves the physiological transition at birth.

    Directory of Open Access Journals (Sweden)

    Sasmira eBhatt

    2014-10-01

    Full Text Available The transition from a fetus to a neonate at birth represents a critical phase in our life. Most infants make this transition without complications, but preterm infants usually require some form of assistance due to immature cardiopulmonary systems that predispose them to lifelong sequelae. As the incidence of preterm birth is increasing, there is now an urgent need for the development of management strategies that facilitate this transition, which will likely include improved strategies for the management of the maternal third stage of labour. For instance, recent studies on the physiological transition at birth have led to the discovery that establishing ventilation in the infant before the umbilical cord is clamped greatly stabilizes the cardiovascular transition at birth. While most benefits of delayed clamping have previously been attributed to an increase in placenta to infant blood transfusion, clearly there are other significant benefits for the infant, which are not well understood. Nevertheless, if ventilation can be established before cord clamping in a preterm infant, the large adverse changes in cardiac function that normally accompanies umbilical cord clamping can be avoided. As preterm infants have an immature cerebral vascular bed, large swings in cardiovascular function places them at high risk of cerebral vascular rupture and the associated increased risk of mortality and morbidity. In view of the impact that cord clamping has on the cardiovascular transition at birth, it is also time to re-examine some of the strategies used in the management of the third stage of labour. These include the appropriate timing of uterotonic administration in relation to delivery of the infant and placenta. As there is a lack of evidence on the effects these individual practices have on the infant, there is a necessity to improve our understanding of their impact in order to develop strategies that facilitate the transition to newborn life.

  8. Darlington Station outage - a maintenance perspective

    International Nuclear Information System (INIS)

    Plourde, J.; Marczak, J.; Stone, M.; Myers, R.; Sutton, K.

    1997-01-01

    Ontario Hydro's Darlington Nuclear Generating Station (4x881MW(e)net) has carried out its first station outage since full commercial operation. The outage presented challenges to the organization in terms of outage planning, support, management, and safe execution within the constraints of schedule, budget and resources. This paper will focus on the success of the outage maintenance program, identifying the major work programs - a vacuum structure and containment outage, an emergency service water system outage, an emergency coolant injection system outage, intake channel inspections, low pressure service water inspections, and significant outage maintenance work on each of the four reactor units. Planning for the outage was initiated early in anticipation of this important milestone in the station's life. Detailed safety reviews - nuclear, radiation, and conventional - were conducted in support of the planned maintenance program. System lineup and work protection were provided by the Station Operator work group. Work protection permitry was initiated well in advance of the outage. Station maintenance staff resources were bolstered in support of the outage to ensure program execution could be maintained within the schedule. Training programs were in place to ensure that expectations were clear and that high standards would be maintained. Materials management issues in support of maintenance activities were given high priority to ensure no delays to the planned work. Station management review and monitoring in preparation for and during the outage ensured that staff priorities remained focused. Lessons learned from the outage execution are being formalized in maintenance procedures and outage management procedures, and shared with the nuclear community. (author)

  9. CLAMP - a toolkit for efficiently building customized clinical natural language processing pipelines.

    Science.gov (United States)

    Soysal, Ergin; Wang, Jingqi; Jiang, Min; Wu, Yonghui; Pakhomov, Serguei; Liu, Hongfang; Xu, Hua

    2017-11-24

    Existing general clinical natural language processing (NLP) systems such as MetaMap and Clinical Text Analysis and Knowledge Extraction System have been successfully applied to information extraction from clinical text. However, end users often have to customize existing systems for their individual tasks, which can require substantial NLP skills. Here we present CLAMP (Clinical Language Annotation, Modeling, and Processing), a newly developed clinical NLP toolkit that provides not only state-of-the-art NLP components, but also a user-friendly graphic user interface that can help users quickly build customized NLP pipelines for their individual applications. Our evaluation shows that the CLAMP default pipeline achieved good performance on named entity recognition and concept encoding. We also demonstrate the efficiency of the CLAMP graphic user interface in building customized, high-performance NLP pipelines with 2 use cases, extracting smoking status and lab test values. CLAMP is publicly available for research use, and we believe it is a unique asset for the clinical NLP community. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Effect of complete hilar versus only renal artery clamping on renal histomorphology following ischemia/reperfusion injury in an experimental model.

    Science.gov (United States)

    Umul, M; Cal, A C; Turna, B; Oktem, G; Aydın, H H

    2016-01-01

    To evaluate the effect of temporary complete hilar versus only renal artery clamping with different duration of warm ischemia on renal functions, and possibly identify a "safe" clamping type and duration of renal ischemia. Fifty male rabbits have been incorporated to study. Rabbits were subjected to ischemia/reperfusion injury by temporary vascular clamping. Reagents were randomized to 3 experimental groups (only renal artery clamping, complete hilar clamping, sham surgery) and sub-groups were determined according to different clamping times (30 and 60 minutes). Median laparotomy and left renal hilus dissection were performed to sham group. Only artery or complete hilar clamping was performed for 30 or 60 minutes by microvascular bulldog clamps to other reagents. Rabbits were sacrificed 10 days after primary surgery and left nephrectomy performed. Nephrectomy materials were evaluated for the level of nitric-oxide synthase (NOS) immunoreactivity, malondialdehyde (MDA) level and superoxide dismutase (SOD) activity and an electron microscopic examination was performed. NOS immunoreactivity was correlated with the temporary clamping time. We also observed that complete hilar vascular clamping entails an increase on NOS immunoreactivity. MDA levels were similar for all experimental surgery groups (p = 0.42). The SOD activity was decreased among all subgroups compared with sham surgery. But the significant decrease occurred in 30 minutes only artery and 30 minutes complete hilar clamping groups in proportion to sham surgery (p = 0.026 and p = 0.019, respectively). This current study suggested that only renal artery clamping under 30 minutes is more appropriate during renal surgical procedures requiring temporary vascular clamping.

  11. Safety planning for nuclear power stations

    International Nuclear Information System (INIS)

    Tadmor, J.

    1979-01-01

    The article shows that compared to the many industries and other human activities, nuclear power stations are among the safest. A short description of the measures taken to prevent accidents and of the additional safety means entering into action if an accident does occur is presented. It is shown that in nuclear plants the death frequency following malfunctioning is 1 death in 100.000 years whereas deaths following other human activities is 1 in 2 to 100 years and following natural calamities like earthquakes and floods is 1 in 10 years. As an example it is shown that for a population of 15.000.000 living in a radius of 40 km around 100 power stations the average number of deaths will be of 2 per year as compared to 4200 from road accidents with the corresponding number of injuries of 20 and 375.000 respectively. (B.G.)

  12. Fire social science research from the Pacific Southwest research station: studies supported by national fire plan funds

    Science.gov (United States)

    Deborah J. Chavez; James D. Absher; Patricia L. Winter

    2008-01-01

    Fire events often have a large impact on recreation and tourism, yet these issues had not been addressed from a social science perspective. To address his, the Wildland Recreation and Urban Cultures Research Work Unit (RWU) of the Pacific Southwest Research Station acquired funding through the National Fire Plan within the community assistance topic area. The three...

  13. Three Level Diode Clamped Inverter Fed Induction Motor with Dtc-Svm

    OpenAIRE

    V. Ranjith Kumar

    2013-01-01

    This project presents a three-level diode-clamped inverter feeding an asynchronous motor drive with direct torque control (DTC). The control method is based on DTC operating principles. The stator voltage vector reference is computed from the stator flux and torque errors imposed by the flux and torque controllers. This voltage reference is then generated using a diode-clamped inverter, where each phase of the inverter can be implemented using a dc source, which would be available from fuel c...

  14. Application of modern tools and techniques to maximize engineering productivity in the development of orbital operations plans for the space station progrm

    Science.gov (United States)

    Manford, J. S.; Bennett, G. R.

    1985-01-01

    The Space Station Program will incorporate analysis of operations constraints and considerations in the early design phases to avoid the need for later modifications to the Space Station for operations. The application of modern tools and administrative techniques to minimize the cost of performing effective orbital operations planning and design analysis in the preliminary design phase of the Space Station Program is discussed. Tools and techniques discussed include: approach for rigorous analysis of operations functions, use of the resources of a large computer network, and providing for efficient research and access to information.

  15. Suppression of Spiral Waves by Voltage Clamp Techniques in a Conductance-Based Cardiac Tissue Model

    International Nuclear Information System (INIS)

    Lian-Chun, Yu; Guo-Yong, Zhang; Yong, Chen; Jun, Ma

    2008-01-01

    A new control method is proposed to control the spatio-temporal dynamics in excitable media, which is described by the Morris–Lecar cells model. It is confirmed that successful suppression of spiral waves can be obtained by spatially clamping the membrane voltage of the excitable cells. The low voltage clamping induces breakup of spiral waves and the fragments are soon absorbed by low voltage obstacles, whereas the high voltage clamping generates travel waves that annihilate spiral waves through collision with them. However, each method has its shortcomings. Furthermore, a two-step method that combines both low and high voltage clamp techniques is then presented as a possible way of out this predicament. (cross-disciplinary physics and related areas of science and technology)

  16. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization

    Science.gov (United States)

    Kim, Hojin; Li, Ruijiang; Lee, Rena; Xing, Lei

    2015-03-01

    Conventional VMAT optimizes aperture shapes and weights at uniformly sampled stations, which is a generalization of the concept of a control point. Recently, rotational station parameter optimized radiation therapy (SPORT) has been proposed to improve the plan quality by inserting beams to the regions that demand additional intensity modulations, thus formulating non-uniform beam sampling. This work presents a new rotational SPORT planning strategy based on reweighted total-variation (TV) minimization (min.), using beam’s-eye-view dosimetrics (BEVD) guided beam selection. The convex programming based reweighted TV min. assures the simplified fluence-map, which facilitates single-aperture selection at each station for single-arc delivery. For the rotational arc treatment planning and non-uniform beam angle setting, the mathematical model needs to be modified by additional penalty term describing the fluence-map similarity and by determination of appropriate angular weighting factors. The proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional VMAT and SPORT planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (HN) cases with a single and multiple targets). The BEVD guided beam selection provides effective and yet easy calculating methodology to select angles for denser, non-uniform angular sampling in SPORT planning. Our BEVD guided SPORT treatment schemes improve the dose sparing to femoral heads in the prostate and brainstem, parotid glands and oral cavity in the two HN cases, where the mean dose reduction of those organs ranges from 0.5 to 2.5 Gy. Also, it increases the conformation number assessing the dose conformity to the target from 0.84, 0.75 and 0.74 to 0.86, 0.79 and 0.80 in the prostate and two HN cases, while preserving the delivery efficiency, relative to conventional single-arc VMAT plans.

  17. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization

    International Nuclear Information System (INIS)

    Kim, Hojin; Li, Ruijiang; Xing, Lei; Lee, Rena

    2015-01-01

    Conventional VMAT optimizes aperture shapes and weights at uniformly sampled stations, which is a generalization of the concept of a control point. Recently, rotational station parameter optimized radiation therapy (SPORT) has been proposed to improve the plan quality by inserting beams to the regions that demand additional intensity modulations, thus formulating non-uniform beam sampling. This work presents a new rotational SPORT planning strategy based on reweighted total-variation (TV) minimization (min.), using beam’s-eye-view dosimetrics (BEVD) guided beam selection. The convex programming based reweighted TV min. assures the simplified fluence-map, which facilitates single-aperture selection at each station for single-arc delivery. For the rotational arc treatment planning and non-uniform beam angle setting, the mathematical model needs to be modified by additional penalty term describing the fluence-map similarity and by determination of appropriate angular weighting factors. The proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional VMAT and SPORT planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (HN) cases with a single and multiple targets). The BEVD guided beam selection provides effective and yet easy calculating methodology to select angles for denser, non-uniform angular sampling in SPORT planning. Our BEVD guided SPORT treatment schemes improve the dose sparing to femoral heads in the prostate and brainstem, parotid glands and oral cavity in the two HN cases, where the mean dose reduction of those organs ranges from 0.5 to 2.5 Gy. Also, it increases the conformation number assessing the dose conformity to the target from 0.84, 0.75 and 0.74 to 0.86, 0.79 and 0.80 in the prostate and two HN cases, while preserving the delivery efficiency, relative to conventional single-arc VMAT plans

  18. Substrate clamping effects on irreversible domain wall dynamics in lead zirconate titanate thin films.

    Science.gov (United States)

    Griggio, F; Jesse, S; Kumar, A; Ovchinnikov, O; Kim, H; Jackson, T N; Damjanovic, D; Kalinin, S V; Trolier-McKinstry, S

    2012-04-13

    The role of long-range strain interactions on domain wall dynamics is explored through macroscopic and local measurements of nonlinear behavior in mechanically clamped and released polycrystalline lead zirconate-titanate (PZT) films. Released films show a dramatic change in the global dielectric nonlinearity and its frequency dependence as a function of mechanical clamping. Furthermore, we observe a transition from strong clustering of the nonlinear response for the clamped case to almost uniform nonlinearity for the released film. This behavior is ascribed to increased mobility of domain walls. These results suggest the dominant role of collective strain interactions mediated by the local and global mechanical boundary conditions on the domain wall dynamics. The work presented in this Letter demonstrates that measurements on clamped films may considerably underestimate the piezoelectric coefficients and coupling constants of released structures used in microelectromechanical systems, energy harvesting systems, and microrobots.

  19. Γ-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    Transformer based Z-source inverters are recently proposed to achieve promising buck-boost capability. They have improved higher buck-boost capability, smaller size and less components count over Z-source inverters. On the other hand, neutral point clamped inverters have less switching stress...... and better output performance comparing with traditional two-level inverters. Integrating these two types of configurations can help neutral point inverters achieve enhanced votlage buck-boost capability....

  20. Constant-frequency, clamped-mode resonant converters

    Science.gov (United States)

    Tsai, Fu-Sheng; Materu, Peter; Lee, Fred C.

    1987-01-01

    Two novel clamped-mode resonant converters are proposed which operate at a constant frequency while retaining many desired features of conventional series- and parallel-resonant converters. State-plane analysis techniques are used to identify all possible operating modes and define their mode boundaries. Control-to-output characteristics are derived that specify the regions for natural and forced commutation. The predicted operating modes are verified using a prototype circuit.

  1. The optimal protocol to reduce blood loss and blood transfusion after unilateral total knee replacement: Low-dose IA-TXA plus 30-min drain clamping versus drainage clamping for the first 3 h without IA-TXA.

    Science.gov (United States)

    Park, Joo Hyun; Choi, Sung Wook; Shin, Eun Ho; Park, Myung Hoon; Kim, Myung Ku

    2017-01-01

    Although intraarticular tranexamic acid (IA-TXA) administration or drainage clamping are popular methods used to reduce blood loss after total knee replacement (TKR), the protocol remains controversial. We aimed (1) to establish new protocols through investigating whether two methods, that is, low-dose (500 mg) IA-TXA plus 30-min drain clamping and drainage clamping for the first 3 h without IA-TXA, can reduce blood loss and blood transfusion after unilateral TKR and (2) to make recommendations related to clinical application. This study, conducted from September 2014 to June 2016 related to enrolled 95 patients with primary osteoarthritis who were to have a unilateral cemented TKR, was nonrandomized and retrospective. In group A, the drain was released following tourniquet deflation. In group B, 500-mg TXA was injected into the knee joint via a drain tube after fascia closure and the drain was clamped for the first 30 min to prevent leakage. In group C, the drain was clamped for the first 3-h postoperation. Demographic characteristics and clinical data were collected, including the levels of hematocrit (Hct), the total blood loss (TBL), drained blood volume (BV), the amount of blood transfused, and any complications that developed. We found a significantly lower postoperative TBL, drained BV, decreasing Hct level, and less transfused BV in the IA-TXA injection group (group B) and the 3-h drainage clamping group (group C) compared to the conventional negative drainage group (group A; p optimal than drainage clamping in patients with high bleeding tendency or lateral retinacular release during TKR, who would be concerned about postoperative wound complication.

  2. [The Impact of Late Umbilical Cord Clamping on Neonatal Jaundice and Postpartum Hemorrhage: A Randomized Controlled Trail].

    Science.gov (United States)

    Chien, Pei-Chun; Yang, Cherng-Chia; Gau, Meei-Ling; Liu, Chieh-Yu; Lee, Tzu-Ying

    2015-08-01

    The current evidence supports the clinical benefits of late umbilical cord clamping. These benefits include increased blood volume and total body iron. Furthermore, delayed cord clamping facilitates the transplantation of stem cells, which helps the development of infant bodily systems. However, due to concerns related to postpartum hemorrhaging and neonate jaundice, most maternity units still clamp the cord immediately after a child is born. This study investigates the impact of delaying cord clamping on neonatal jaundice and postpartum hemorrhage. A randomized, controlled trial was conducted at a regional teaching hospital in northern Taiwan. One hundred and five healthy nulliparous women at 36 weeks of pregnancy were included and allocated randomly to the experiment group (n=44) and the control group (n=61). Participants in the experiment group received delayed cord clamping (DCC) at 3 minutes after delivery. Participants in the control group received early cord clamping (ECC) at around 1 minute after delivery. Clinical measures of the outcomes were measured by the infant transcutaneous bilirubin levels (TcB) and postpartum hemorrhage at birth. A structured questionnaire and biophysical measures were used to collect data on participant demographics, obstetrical information, maternal blood loss at birth, neonate weight and TcB level at hospitalization, and whether or not the infant received phototherapy at 4-7 days postpartum. Overall, there was no significant difference between the two groups in terms of neonatal jaundice, maternal hemorrhage at birth, and phototherapy rates at time of hospitalization and at 4-7 days postpartum. The findings of the present study support that late umbilical cord clamping does not increase the risk of maternal postpartum hemorrhaging or neonate jaundice. Thus, we suggest that clinicians inform clients during prenatal classes of the benefits of delayed cord clamping and also use current, evidence-based knowledge to dispel client

  3. Robotic Automation of In Vivo Two-Photon Targeted Whole-Cell Patch-Clamp Electrophysiology.

    Science.gov (United States)

    Annecchino, Luca A; Morris, Alexander R; Copeland, Caroline S; Agabi, Oshiorenoya E; Chadderton, Paul; Schultz, Simon R

    2017-08-30

    Whole-cell patch-clamp electrophysiological recording is a powerful technique for studying cellular function. While in vivo patch-clamp recording has recently benefited from automation, it is normally performed "blind," meaning that throughput for sampling some genetically or morphologically defined cell types is unacceptably low. One solution to this problem is to use two-photon microscopy to target fluorescently labeled neurons. Combining this with robotic automation is difficult, however, as micropipette penetration induces tissue deformation, moving target cells from their initial location. Here we describe a platform for automated two-photon targeted patch-clamp recording, which solves this problem by making use of a closed loop visual servo algorithm. Our system keeps the target cell in focus while iteratively adjusting the pipette approach trajectory to compensate for tissue motion. We demonstrate platform validation with patch-clamp recordings from a variety of cells in the mouse neocortex and cerebellum. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  4. [STEM on Station Education

    Science.gov (United States)

    Lundebjerg, Kristen

    2016-01-01

    The STEM on Station team is part of Education which is part of the External Relations organization (ERO). ERO has traditional goals based around BHAG (Big Hairy Audacious Goal). The BHAG model is simplified to a saying: Everything we do stimulates actions by others to advance human space exploration. The STEM on Station education initiate is a project focused on bringing off the earth research and learning into classrooms. Educational resources such as lesson plans, activities to connect with the space station and STEM related contests are available and hosted by the STEM on Station team along with their partners such as Texas Instruments. These educational activities engage teachers and students in the current happenings aboard the international space station, inspiring the next generation of space explorers.

  5. Design and experimental research of a novel inchworm type piezo-driven rotary actuator with the changeable clamping radius.

    Science.gov (United States)

    Zhao, Hongwei; Fu, Lu; Ren, Luquan; Huang, Hu; Fan, Zunqiang; Li, Jianping; Qu, Han

    2013-01-01

    In this paper, a novel piezo-driven rotary actuator with the changeable clamping radius is developed based on the inchworm principle. This actuator mainly utilizes three piezoelectric actuators, a flexible gripper, a clamping block, and a rotor to achieve large stroke rotation with high resolution. The design process of the flexible gripper consisting of the driving unit and the clamping unit is described. Lever-type mechanisms were used to amplify the micro clamping displacements. The amplifying factor and parasitic displacement of the lever-type mechanism in the clamping unit was analyzed theoretically and experimentally. In order to investigate the rotation characteristics of the actuator, a series of experiments was carried out. Experimental results indicate that the actuator can rotate at a speed of 77,488 μrad/s with a driving frequency of 167 Hz. The rotation resolution and maximum load torque of the actuator are 0.25 μrad and 37 N mm, respectively. The gripper is movable along the z direction based on an elevating platform, and the clamping radius can change from 10.6 mm to 25 mm. Experimental results confirm that the actuator can achieve different rotation speeds by changing the clamping radius.

  6. Experimental determination of optimal clamping torque for AB-PEM Fuel cell

    Directory of Open Access Journals (Sweden)

    Noor Ul Hassan

    2016-04-01

    Full Text Available Polymer electrolyte Membrane (PEM fuel cell is an electrochemical device producing electricity by the reaction of hydrogen and oxygen without combustion. PEM fuel cell stack is provided with an appropriate clamping torque to prevent leakage of reactant gases and to minimize the contact resistance between gas diffusion media (GDL and bipolar plates. GDL porous structure and gas permeability is directly affected by the compaction pressure which, consequently, drastically change the fuel cell performance. Various efforts were made to determine the optimal compaction pressure and pressure distributions through simulations and experimentation. Lower compaction pressure results in increase of contact resistance and also chances of leakage. On the other hand, higher compaction pressure decreases the contact resistance but also narrows down the diffusion path for mass transfer from gas channels to the catalyst layers, consequently, lowering cell performance. The optimal cell performance is related to the gasket thickness and compression pressure on GDL. Every stack has a unique assembly pressure due to differences in fuel cell components material and stack design. Therefore, there is still need to determine the optimal torque value for getting the optimal cell performance. This study has been carried out in continuation of deve­lopment of Air breathing PEM fuel cell for small Unmanned Aerial Vehicle (UAV application. Compaction pressure at minimum contact resistance was determined and clamping torque value was calcu­la­ted accordingly. Single cell performance tests were performed at five different clamping torque values i.e 0.5, 1.0, 1.5, 2.0 and 2.5 N m, for achieving optimal cell per­formance. Clamping pressure distribution tests were also performed at these torque values to verify uniform pressure distribution at optimal torque value. Experimental and theoretical results were compared for making inferences about optimal cell perfor­man­ce. A

  7. Combined acute hyperglycemic and hyperinsulinemic clamp induced profibrotic and proinflammatory responses in the kidney.

    Science.gov (United States)

    Mariappan, Meenalakshmi M; DeSilva, Kristin; Sorice, Gian Pio; Muscogiuri, Giovanna; Jimenez, Fabio; Ahuja, Seema; Barnes, Jefferey L; Choudhury, Goutam Ghosh; Musi, Nicolas; DeFronzo, Ralph; Kasinath, Balakuntalam S

    2014-02-01

    Increase in matrix protein content in the kidney is a cardinal feature of diabetic kidney disease. While renal matrix protein content is increased by chronic hyperglycemia, whether it is regulated by acute elevation of glucose and insulin has not been addressed. In this study, we aimed to evaluate whether short duration of combined hyperglycemia and hyperinsulinemia, mimicking the metabolic environment of prediabetes and early type 2 diabetes, induces kidney injury. Normal rats were subjected to either saline infusion (control, n = 4) or 7 h of combined hyperglycemic-hyperinsulinemic clamp (HG+HI clamp; n = 6). During the clamp, plasma glucose and plasma insulin were maintained at about 350 mg/dl and 16 ng/ml, respectively. HG+HI clamp increased the expression of renal cortical transforming growth factor-β (TGF-β) and renal matrix proteins, laminin and fibronectin. This was associated with the activation of SMAD3, Akt, mammalian target of rapamycin (mTOR) complexes, and ERK signaling pathways and their downstream target events in the initiation and elongation phases of mRNA translation, an important step in protein synthesis. Additionally, HG+HI clamp provoked renal inflammation as shown by the activation of Toll-like receptor 4 (TLR4) and infiltration of CD68-positive monocytes. Urinary F2t isoprostane excretion, an index of renal oxidant stress, was increased in the HG+HI clamp rats. We conclude that even a short duration of hyperglycemia and hyperinsulinemia contributes to activation of pathways that regulate matrix protein synthesis, inflammation, and oxidative stress in the kidney. This finding could have implications for the control of short-term rises in blood glucose in diabetic individuals at risk of developing kidney disease.

  8. Protein associations in DnaA-ATP hydrolysis mediated by the Hda-replicase clamp complex.

    Science.gov (United States)

    Su'etsugu, Masayuki; Shimuta, Toh-Ru; Ishida, Takuma; Kawakami, Hironori; Katayama, Tsutomu

    2005-02-25

    In Escherichia coli, the activity of ATP-bound DnaA protein in initiating chromosomal replication is negatively controlled in a replication-coordinated manner. The RIDA (regulatory inactivation of DnaA) system promotes DnaA-ATP hydrolysis to produce the inactivated form DnaA-ADP in a manner depending on the Hda protein and the DNA-loaded form of the beta-sliding clamp, a subunit of the replicase holoenzyme. A highly functional form of Hda was purified and shown to form a homodimer in solution, and two Hda dimers were found to associate with a single clamp molecule. Purified mutant Hda proteins were used in a staged in vitro RIDA system followed by a pull-down assay to show that Hda-clamp binding is a prerequisite for DnaA-ATP hydrolysis and that binding is mediated by an Hda N-terminal motif. Arg(168) in the AAA(+) Box VII motif of Hda plays a role in stable homodimer formation and in DnaA-ATP hydrolysis, but not in clamp binding. Furthermore, the DnaA N-terminal domain is required for the functional interaction of DnaA with the Hda-clamp complex. Single cells contain approximately 50 Hda dimers, consistent with the results of in vitro experiments. These findings and the features of AAA(+) proteins, including DnaA, suggest the following model. DnaA-ATP is hydrolyzed at a binding interface between the AAA(+) domains of DnaA and Hda; the DnaA N-terminal domain supports this interaction; and the interaction of DnaA-ATP with the Hda-clamp complex occurs in a catalytic mode.

  9. MEMS-based clamp with a passive hold function for precision position retaining of micro manipulators

    International Nuclear Information System (INIS)

    Brouwer, D M; Van Dijk, J; Soemers, H M J R; De Jong, B R; De Boer, M J; Jansen, H V; Krijnen, G J M

    2009-01-01

    In this paper the design, modeling and fabrication of a precision MEMS-based clamp with a relatively large clamping force are presented. The purpose of the clamp is to mechanically fix a six-degree-of-freedom (DOF) MEMS-based sample manipulator (Brouwer et al J. Int. Soc. Precis. Eng. Nanotechnol. submitted) once the sample has been positioned in all DOFs. The clamping force is generated by a rotational electrostatic comb-drive actuator and can be latched passively by a parallel plate type electrostatically driven locking device. The clamp design is based on the principles of exact constraint design, resulting in a high actuation compliance (flexibility) combined with a high suspension stiffness. Therefore, a relatively large blocking force of 1.4 mN in relation to the used area of 1.8 mm 2 is obtained. The fabrication is based on silicon bulk micromachining technology and combines a high-aspect-ratio deep reactive ion etching (DRIE), conformal deposition of low-pressure chemical vapor deposition (LPCVD) silicon nitride and an anisotropic potassium hydroxide (KOH) backside etching technology. Special attention is given to void reduction of Si x N y trench isolation and reduction of heating phenomena during front-side release etching. Guidelines are given for the applied process. Measurements showed that the clamp was able to fix, hold and release a test actuator. The dynamic behavior was in good agreement with the modal analysis

  10. Central station market development strategies for photovoltaics

    Science.gov (United States)

    1980-01-01

    Federal market development strategies designed to accelerate the market penetration of central station applications of photovoltaic energy system are analyzed. Since no specific goals were set for the commercialization of central station applications, strategic principles are explored which, when coupled with specific objectives for central stations, can produce a market development implementation plan. The study includes (1) background information on the National Photovoltaic Program, photovoltaic technology, and central stations; (2) a brief market assessment; (3) a discussion of the viewpoints of the electric utility industry with respect to solar energy; (4) a discussion of commercialization issues; and (5) strategy principles. It is recommended that a set of specific goals and objectives be defined for the photovoltaic central station program, and that these goals and objectives evolve into an implementation plan that identifies the appropriate federal role.

  11. Enhancing endogenous stem cells in the newborn via delayed umbilical cord clamping

    Directory of Open Access Journals (Sweden)

    Christopher Lawton

    2015-01-01

    Full Text Available There is currently no consensus among clinicians and scientists over the appropriate or optimal timing for umbilical cord clamping. However, many clinical studies have suggested that delayed cord clamping is associated with various neonatal benefits including increased blood volume, reduced need for blood transfusion, increased cerebral oxygenation in pre-term infants, and decreased frequency of iron deficiency anemia in term infants. Human umbilical cord blood contains significant amounts of stem and progenitor cells and is currently used in the treatment of several life-threatening diseases. We propose that delayed cord clamping be encouraged as it enhances blood flow from the placenta to the neonate, which is accompanied by an increase supply of valuable stem and progenitor cells, as well as may improve blood oxygenation and increase blood volume, altogether reducing the infant′s susceptibility to both neonatal and age-related diseases.

  12. The evaluation on clamping force of high strength bolts by length parameter

    International Nuclear Information System (INIS)

    Kim, Kang-Seok; Nah, Hwan-Seon; Lee, Hyeon-Ju; Lee, Kang-Min

    2009-01-01

    It has been reported that the length parameter of high strength bolts results in the variance in tension loads. The required turn for each length is specified in AISC RCSC specification. This study was focused on evaluating any influence on the clamping torque subjected to length parameter of high strength bolts. The two kinds of high strength bolts of specimen are as follows; High Strength Hexagon bolt defined on ASTM A490 and Torque Shear Bolt on KS B 2819. The length parameter ranged from 60mm(3d) to 140mm(7d). The torque, turn of nut and the clamping force were analyzed to review whether length parameter can be affected on the required tension load. To test whether the length parameter has an impact on the torque and turn of nut for the required strength and clamping force, statistical analysis is carried out. (author)

  13. Thermodynamic basis for engineering high-affinity, high-specificity binding-induced DNA clamp nanoswitches.

    Science.gov (United States)

    Idili, Andrea; Plaxco, Kevin W; Vallée-Bélisle, Alexis; Ricci, Francesco

    2013-12-23

    Naturally occurring chemoreceptors almost invariably employ structure-switching mechanisms, an observation that has inspired the use of biomolecular switches in a wide range of artificial technologies in the areas of diagnostics, imaging, and synthetic biology. In one mechanism for generating such behavior, clamp-based switching, binding occurs via the clamplike embrace of two recognition elements onto a single target molecule. In addition to coupling recognition with a large conformational change, this mechanism offers a second advantage: it improves both affinity and specificity simultaneously. To explore the physics of such switches we have dissected here the thermodynamics of a clamp-switch that recognizes a target DNA sequence through both Watson-Crick base pairing and triplex-forming Hoogsteen interactions. When compared to the equivalent linear DNA probe (which relies solely on Watson-Crick interactions), the extra Hoogsteen interactions in the DNA clamp-switch increase the probe's affinity for its target by ∼0.29 ± 0.02 kcal/mol/base. The Hoogsteen interactions of the clamp-switch likewise provide an additional specificity check that increases the discrimination efficiency toward a single-base mismatch by 1.2 ± 0.2 kcal/mol. This, in turn, leads to a 10-fold improvement in the width of the "specificity window" of this probe relative to that of the equivalent linear probe. Given these attributes, clamp-switches should be of utility not only for sensing applications but also, in the specific field of DNA nanotechnology, for applications calling for a better control over the building of nanostructures and nanomachines.

  14. Study of the mechanism of clamping and detachment of a core sample by core lever lifters

    Energy Technology Data Exchange (ETDEWEB)

    Barabashkin, I I; Mizyakin, V M; Nikitin, S V

    1981-01-01

    Geometric dimensions of the basic elements of a core lifter should be determined depending on the clamping conditions. The changes should be determined depending on the conditions of the core sample diameter, critical angle between the lever and the core samples in the necessary depth of submersion of the contact edge of the lever into its surface. The core lifter KTsRZ-80 with eccentric core reception makes it possible to arrange more efficiently the core removing elements on the edge of the band. The use of the core lifters with eccentric plan of arrangement of the levers and their optimal length increases the removal of the core sample.

  15. A plan for time-phased incorporation of automation and robotics on the US space station

    Science.gov (United States)

    Purves, R. B.; Lin, P. S.; Fisher, E. M., Jr.

    1988-01-01

    A plan for the incorporation of Automation and Robotics technology on the Space Station is presented. The time phased introduction of twenty two selected candidates is set forth in accordance with a technology development forecast. Twenty candidates were chosed primarily for their potential to relieve the crew of mundane or dangerous operations and maintenance burdens, thus freeing crew time for mission duties and enhancing safety. Two candidates were chosen based on a potential for increasing the productivity of laboratory experiments and thus directly enhancing the scientific value of the Space Station. A technology assessment for each candidate investigates present state of the art, development timelines including space qualification considerations, and potential for technology transfer to earth applications. Each candidate is evaluated using a crew workload model driven by crew size, number of pressurized U.S. modules and external payloads, which makes it possible to assess the impact of automation during a growth scenario. Costs for each increment of implementation are estimated and accumulated.

  16. Reversible fastener clamp load monitor with continuous visual or remote readout

    Science.gov (United States)

    Hodge, Malcolm H.; Kausel, Theodore C., Jr.; Begley, Matthew R.

    1998-03-01

    SIMS has developed a simple means for detecting and monitoring both absolute and relative clamp load, or bolt tension, in fastener systems. More than twenty-five percent of automotive failures are known to be due to undetected loss of fastener clamp load. While the equivalent aerospace maintenance statistics are not known, the average automobile has 3,500 fasteners while a Boeing 747 has closer to one million. It is therefore anticipated that the new SensaBolt clamp load tracking system could find wide applications in the aerospace arena. We describe a visually-evident and retrofitted clamp load monitoring design which is based on the differential joint substrate compression at, and immediately adjacent to, the fastener location. This intrinsically-accurate indicator does not necessarily require alteration in either the bolt or nut geometries, thereby facilitating product introduction and retrofit in aging aircraft applications. In addition, SensaBolt's sole reliance on substrate compression renders it more accurate then torque wrench or turn-of-nut techniques. Readout may be accomplished by any of three principal methods: for those applications with ease of access to the sensor, loss of tension can be determined by direct visual inspection. Application of a standard wrench can then be made to restore the fastener's proper tightness, per the SensaBolt indicators. In those instances where line-of-sight is unimpeded and more formal inspection is desired, the SensaBolt may be interrogated by a laser scanner bar code reader. Finally, SensaBolt may be addressed by the SIMS fiber optic harness for those instances where full-time remote interrogation is desired.

  17. A simple technique to measure regional cerebral blood flow during intravascular ballon clamping

    International Nuclear Information System (INIS)

    Furuhata, Shigeru; Kubo, Atsushi; Kawase, Takeshi; Ibata, Yukio; Toya, Shigeo

    1988-01-01

    A case of giant internal carotid ophthalmic aneurysm was presented. In order to clarify whether the patient could tolerate carotid occlusion, a ballon clamping test was performed before surgery. The cerebral blood flow was measured using early imaging by single photon emission computed tomography (SPECT) with N-isopropyl-(iodine-123)-p-iodoamphetamine ( 123 I-IMP). When the ballon clamping test was performed the tracer was injected, and scanning was performed 35 minutes after removing the catheter. This tracer enabled a 'memory of blood flow' during temporary ischemia to determine the character of quick diffusion and slow wash out, that could not be performed by other methods of cerebral blood flow measurement. SPECT with 123 I-IMP can simplify the measurement of cerebral blood flow during the balloon clamping test. (author)

  18. Final Bioventing Pilot Test Work Plan for Base Exchange Service Station Underground Storage Tank Area, Vandenberg Air Force Base, California. Part I

    National Research Council Canada - National Science Library

    1992-01-01

    This pilot test work plan presents the scope of an in situ enhanced biological degradation, or "bioventing", pilot test for treatment of gasoline- contaminated soils at the Base Exchange Service Station (BXSS...

  19. Interactions Between SNAP-25 and Synaptotagmin-1 Are Involved in Vesicle Priming, Clamping Spontaneous and Stimulating Evoked Neurotransmission

    DEFF Research Database (Denmark)

    Schupp, Melanie; Malsam, Jörg; Ruiter, Marvin

    2016-01-01

    between region I (vesicle priming) and region II (evoked release). Spontaneous release was disinhibited by region I mutations and found to correlate with defective complexin (Cpx) clamping in an in vitro fusion assay, pointing to an interdependent role of synaptotagmin and Cpx in release clamping...... triggering, depend on direct SNARE complex interaction. SIGNIFICANCE STATEMENT: The function of synaptotagmin-1 (syt-1):soluble NSF attachment protein receptor (SNARE) interactions during neurotransmission remains unclear. We mutated SNAP-25 within the recently identified region I and region II...... was disinhibited by region I mutation and found to correlate with defective complexin (Cpx) clamping in vitro, pointing to an interdependent role of synaptotagmin and Cpx in release clamping. Therefore, vesicle priming, clamping spontaneous release, and eliciting evoked release are three different functions of syt...

  20. Applications of Dynamic Clamp to Cardiac Arrhythmia Research: Role in Drug Target Discovery and Safety Pharmacology Testing

    Directory of Open Access Journals (Sweden)

    Francis A. Ortega

    2018-01-01

    Full Text Available Dynamic clamp, a hybrid-computational-experimental technique that has been used to elucidate ionic mechanisms underlying cardiac electrophysiology, is emerging as a promising tool in the discovery of potential anti-arrhythmic targets and in pharmacological safety testing. Through the injection of computationally simulated conductances into isolated cardiomyocytes in a real-time continuous loop, dynamic clamp has greatly expanded the capabilities of patch clamp outside traditional static voltage and current protocols. Recent applications include fine manipulation of injected artificial conductances to identify promising drug targets in the prevention of arrhythmia and the direct testing of model-based hypotheses. Furthermore, dynamic clamp has been used to enhance existing experimental models by addressing their intrinsic limitations, which increased predictive power in identifying pro-arrhythmic pharmacological compounds. Here, we review the recent advances of the dynamic clamp technique in cardiac electrophysiology with a focus on its future role in the development of safety testing and discovery of anti-arrhythmic drugs.

  1. Indian Point Nuclear Power Station: verification analysis of County Radiological Emergency-Response Plans

    International Nuclear Information System (INIS)

    Nagle, J.; Whitfield, R.

    1983-05-01

    This report was developed as a management tool for use by the Federal Emergency Management Agency (FEMA) Region II staff. The analysis summarized in this report was undertaken to verify the extent to which procedures, training programs, and resources set forth in the County Radiological Emergency Response Plans (CRERPs) for Orange, Putnam, and Westchester counties in New York had been realized prior to the March 9, 1983, exercise of the Indian Point Nuclear Power Station near Buchanan, New York. To this end, a telephone survey of county emergency response organizations was conducted between January 19 and February 22, 1983. This report presents the results of responses obtained from this survey of county emergency response organizations

  2. 20 years of power station master training

    International Nuclear Information System (INIS)

    Schwarz, O.

    1977-01-01

    In the early fifties, the VGB working group 'Power station master training' elaborated plans for systematic and uniform training of power station operating personnel. In 1957, the first power station master course was held. In the meantime, 1.720 power station masters are in possession of a master's certificate of a chamber of commerce and trade. Furthermore, 53 power station masters have recently obtained in courses of the 'Kraftwerksschule e.V.' the know-how which enables them to also carry out their duty as a master in nuclear power stations. (orig.) [de

  3. Space Station - An integrated approach to operational logistics support

    Science.gov (United States)

    Hosmer, G. J.

    1986-01-01

    Development of an efficient and cost effective operational logistics system for the Space Station will require logistics planning early in the program's design and development phase. This paper will focus on Integrated Logistics Support (ILS) Program techniques and their application to the Space Station program design, production and deployment phases to assure the development of an effective and cost efficient operational logistics system. The paper will provide the methodology and time-phased programmatic steps required to establish a Space Station ILS Program that will provide an operational logistics system based on planned Space Station program logistics support.

  4. Engineering of electrical systems of nuclear power stations for improved reliability

    International Nuclear Information System (INIS)

    Narasinga Rao, S.N.; Ramanathan, K.; Choudhary, N.N.

    1977-01-01

    Operational problems experienced in electrical systems/equipment of the Tarapur Atomic Power Station (TAPS) and the Rajasthan Atomic Power Station (RAPS) and their solutions are dealt in detail. This experience has led to new design concepts which are being introduced for improved reliability in design of the Madras Atomic Power Project (MAPP) and the Narora Atomic Power Project (NAPP). Saline pollution on switchyard equipments was the major problem of the TAPS due to its coastal location. Saline pollution resulted in flash over of insulators and failure of clamps. The problem was solved by suitable changes in insulators, conductors, transformers, switches and arranging portable live line washing of the switchyard equipment. In MAPP which is also located on coast, an indoor switchyard is built. NAPP is located in a seismic zone, therefore, all equipment is specified for appropriate seismic duty. Various other improvements are described. (M.G.B.)

  5. Life Sciences Space Station planning document: A reference payload for the Life Sciences Research Facility

    Science.gov (United States)

    1986-01-01

    The Space Station, projected for construction in the early 1990s, will be an orbiting, low-gravity, permanently manned facility providing unprecedented opportunities for scientific research. Facilities for Life Sciences research will include a pressurized research laboratory, attached payloads, and platforms which will allow investigators to perform experiments in the crucial areas of Space Medicine, Space Biology, Exobiology, Biospherics and Controlled Ecological Life Support System (CELSS). These studies are designed to determine the consequences of long-term exposure to space conditions, with particular emphasis on assuring the permanent presence of humans in space. The applied and basic research to be performed, using humans, animals, and plants, will increase our understanding of the effects of the space environment on basic life processes. Facilities being planned for remote observations from platforms and attached payloads of biologically important elements and compounds in space and on other planets (Exobiology) will permit exploration of the relationship between the evolution of life and the universe. Space-based, global scale observations of terrestrial biology (Biospherics) will provide data critical for understanding and ultimately managing changes in the Earth's ecosystem. The life sciences community is encouraged to participate in the research potential the Space Station facilities will make possible. This document provides the range and scope of typical life sciences experiments which could be performed within a pressurized laboratory module on Space Station.

  6. Clamped seismic metamaterials: ultra-low frequency stop bands

    International Nuclear Information System (INIS)

    Achaoui, Y; Enoch, S; Guenneau, S; Antonakakis, T; Brûlé, S; Craster, R V

    2017-01-01

    The regularity of earthquakes, their destructive power, and the nuisance of ground vibration in urban environments, all motivate designs of defence structures to lessen the impact of seismic and ground vibration waves on buildings. Low frequency waves, in the range 1–10 Hz for earthquakes and up to a few tens of Hz for vibrations generated by human activities, cause a large amount of damage, or inconvenience; depending on the geological conditions they can travel considerable distances and may match the resonant fundamental frequency of buildings. The ultimate aim of any seismic metamaterial, or any other seismic shield, is to protect over this entire range of frequencies; the long wavelengths involved, and low frequency, have meant this has been unachievable to date. Notably this is scalable and the effects also hold for smaller devices in ultrasonics. There are three approaches to obtaining shielding effects: bragg scattering, locally resonant sub-wavelength inclusions and zero-frequency stop-band media. The former two have been explored, but the latter has not and is examined here. Elastic flexural waves, applicable in the mechanical vibrations of thin elastic plates, can be designed to have a broad zero-frequency stop-band using a periodic array of very small clamped circles. Inspired by this experimental and theoretical observation, all be it in a situation far removed from seismic waves, we demonstrate that it is possible to achieve elastic surface (Rayleigh) wave reflectors at very large wavelengths in structured soils modelled as a fully elastic layer periodically clamped to bedrock. We identify zero frequency stop-bands that only exist in the limit of columns of concrete clamped at their base to the bedrock. In a realistic configuration of a sedimentary basin 15 m deep we observe a zero frequency stop-band covering a broad frequency range of 0–30 Hz. (paper)

  7. Small Molecules for Early Endosome-Specific Patch Clamping.

    Science.gov (United States)

    Chen, Cheng-Chang; Butz, Elisabeth S; Chao, Yu-Kai; Grishchuk, Yulia; Becker, Lars; Heller, Stefan; Slaugenhaupt, Susan A; Biel, Martin; Wahl-Schott, Christian; Grimm, Christian

    2017-07-20

    To resolve the subcellular distribution of endolysosomal ion channels, we have established a novel experimental approach to selectively patch clamp Rab5 positive early endosomes (EE) versus Rab7/LAMP1-positive late endosomes/lysosomes (LE/LY). To functionally characterize ion channels in endolysosomal membranes with the patch-clamp technique, it is important to develop techniques to selectively enlarge the respective organelles. We found here that two small molecules, wortmannin and latrunculin B, enlarge Rab5-positive EE when combined but not Rab7-, LAMP1-, or Rab11 (RE)-positive vesicles. The two compounds act rapidly, specifically, and are readily applicable in contrast to genetic approaches or previously used compounds such as vacuolin, which enlarges EE, RE, and LE/LY. We apply this approach here to measure currents mediated by TRPML channels, in particular TRPML3, which we found to be functionally active in both EE and LE/LY in overexpressing cells as well as in endogenously expressing CD11b+ lung-tissue macrophages. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Current status and future planning of Fukushima Daiichi Nuclear Power Station after Great East Japan earthquake

    International Nuclear Information System (INIS)

    Inouer, Y.

    2012-01-01

    Fukushima Daiichi Nuclear Power Station (NPS) clean-up and decommissioning activities require a lot of R and D and careful project management due to its severity of damage. Inability of access inside the reactor and turbine buildings due to harsh environment results in large uncertainties which make the project planning difficult R and R activities will be conducted in parallel with on-site clean-up and maintenance activities. In order to cope with this unprecedented challenge, the government, laboratories, academicians, vendors, manufacturers, and other partners have joined together to support tokyo electric Power Company, Inc (TEPCO). This paper will summarize the current status and mid-and long-term plan for the clean-up and decommissioning of Units 1 to 4 of Fukushima Daiichi NPS as of March, 2012. (Author) 15 refs.

  9. Long-Time Choledochal Clamping in Wistar Rats Causes Biliary Obstruction Progressing to Hepatic Fibrosis.

    Science.gov (United States)

    Jorge, G D L; Tártaro, R R; Escanhoela, C A F; Boin, I D F S F

    2016-09-01

    Biliary complications are important causes of morbidity and mortality in patients undergoing hepatic surgery. The aim of the study was to evaluate late liver alterations after a long period of choledochal clamping in Wistar rats. Ten male Wistar rats, weighing 304 grams, anesthetized with sodium thiopental (25 mg/kg) and xylazine (10 mg/kg) intravenously, were distributed into 2 groups: the choledochal clamping group (CCG) and the operation sham group (OSG), with 5 animals each submitted to an abdominal incision. In the CCG, the choledochal was isolated, dissected, and clamped with a microvascular clamp for 40 minutes. After this occlusion time, the clamp was removed and the incision was closed. In the OSG the animals, under normal conditions, were submitted only to anesthesia and laparotomy for choledochal manipulation. In all animals, after the 31st day, a hepatic biopsy was carried out for histology and blood biochemical tests: total bilirubin, alkaline phosphatase, aspartate aminotransferase, alanine aminotransferase, and gamma-glutamyl transferase. The animals were euthanized under anesthesia. This research was approved by the Ethics Committee on Animal Use (CEUA, Unicamp, No. 2511-1). In the CCG, 100% of the animals showed bile duct dilatation, ductular proliferation, and portal inflammatory infiltrate; 60% showed regenerative nodule formation; and 80% had porta-porta septa and foci of necrosis, all of which were not found in the OSG. All CCG group biochemical tests had significant increases (P Wistar rats caused hepatic dysfunction and biochemical and histological injuries with degrees of distortion to the hepatic architecture. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. [Time of cord clamping and neonatal complications, a prospective study].

    Science.gov (United States)

    Rincón, D; Foguet, A; Rojas, M; Segarra, E; Sacristán, E; Teixidor, R; Ortega, A

    2014-09-01

    To assess the effects of early or late clamping of the umbilical cord in term newborns, assessing the levels of hemoglobin, hematocrit, and ferritin, and their correlation with some of the complications. A prospective study of healthy newborns at term or born by dystotic or eutocic delivery in our hospital between May 2009 until May 2010. Patients were assigned according to the time of clamping, group 1 (<60 seconds), group 2 (1 to<2 minutes), and group 3 (2 to 3 minutes). Laboratory tests were performed at birth and at 48 hours of life, assessing the levels of hemoglobin, hematocrit, ferritin, and bilirubin. The risk of polycythemia, respiratory distress syndrome, neonatal phototherapy or admission to the Intensive Care Unit and the hospital stay, were evaluated. A total of 242 patients were included: group 1 (g1=80), group 2 (g2=31) y group 3 (g3=131). The background maternal and neonatal characteristics were similar in all sets. The first test showed significant differences in ferritin levels in those infants with delayed clamping (g1: 111 mg/dl, g2: 125 mg/dl, g3: 173 mg/dl; p<0.01). In the second analysis the values of hemoglobin (g1: 17.3 g/dl, g2: 18.9 g/dl, g3: 19.2 g/dl; p<0.01), hematocrit (g1: 53.4%, g2: 58%, g3: 59%; p<0.01) and ferritin (g1: 254 mg/dl, g2: 254.7 mg/dl, g3: 313 mg/dl; p = 0.008) were statistically higher in this group. As regards complications, a significant increase was observed in the number of cases of polycythemia symptoms in group 3. The late cord clamping is associated with an increase in hematocrit, hemoglobin and ferritin at 48 hours of life, as well as an increased risk of polycythemia present with symptoms. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  11. Robotic multi-well planar patch-clamp for native and primary mammalian cells

    Science.gov (United States)

    Milligan, Carol J; Li, Jing; Sukumar, Piruthivi; Majeed, Yasser; Dallas, Mark L; English, Anne; Emery, Paul; Porter, Karen E; Smith, Andrew M; McFadzean, Ian; Beccano-Kelly, Dayne; Bahnasi, Yahya; Cheong, Alex; Naylor, Jacqueline; Zeng, Fanning; Liu, Xing; Gamper, Nikita; Jiang, Lin-Hua; Pearson, Hugh A; Peers, Chris; Robertson, Brian; Beech, David J

    2009-01-01

    Multi-well robotic planar patch-clamp has become common in drug development and safety programmes because it enables efficient and systematic testing of compounds against ion channels during voltage-clamp. It has not, however, been adopted significantly in other important areas of ion channel research, where conventional patch-clamp remains the favoured method. Here we show the wider potential of the multi-well approach with the capability for efficient intracellular solution exchange, describing protocols and success rates for recording from a range of native and primary mammalian cells derived from blood vessels, arthritic joints, and the immune and central nervous systems. The protocol involves preparing a suspension of single cells to be dispensed robotically into 4-8 microfluidic chambers each containing a glass chip with a small aperture. Under automated control, giga-seals and whole-cell access are achieved followed by pre-programmed routines of voltage paradigms and fast extracellular or intracellular solution exchange. Recording from 48 chambers usually takes 1-6 hr depending on the experimental design and yields 16-33 cell recordings. PMID:19197268

  12. Risk impact of planned maintenance configuration at South Texas Project Electric Generating Station

    International Nuclear Information System (INIS)

    Loh, W.T.; Fleming, K.N.; Grantom, C.R.

    2004-01-01

    This paper is based on a study done for the Houston Lighting and Power Company. The purpose of this study is to estimate the risk impact of planned maintenance configurations at South Texas Project Electric Generating Station (STPEGS). To date, the focus of the STP probabilistic safety assessment (PSA) program has been to analyze risk in terms of estimates of accident frequencies that are expressed on a time-averaged basis. Thus, estimates of quantities such as severe core damage frequency have been made such that the temporal variations of this frequency with changing plant configurations are averaged out over time. The only condition that has been imposed on these estimates is that the plant is initially operating at full power when potential initiating events might occur. (author)

  13. Central Station Design Options

    DEFF Research Database (Denmark)

    2011-01-01

    . The work identifies the architecture, sizing and siting of prospective Central Stations in Denmark, which can be located at shopping centers, large car parking lots or gas stations. Central Stations are planned to be integrated in the Danish distribution grid. The Danish island of Bornholm, where a high...... overloading, more reference points might be necessary to represent various transformer loading levels. The subject of safety in Central Station is also addressed. A number of safety rules based on European standards apply to AC charging equipment up to 44 kW. The connection interlock and the automatic de......-energization are identified as fundamental requirements for safety in such a charging station. The connection interlock is a solution which ensures that no power is applied to the DC cable when the EV connector is not connected. The automatic de-energization device ensures that whenever a strain on the cable is detected, e...

  14. Modeling error and apparent isotope discrimination confound estimation of endogenous glucose production during euglycemic glucose clamps

    International Nuclear Information System (INIS)

    Finegood, D.T.; Bergman, R.N.; Vranic, M.

    1988-01-01

    We previously demonstrated that conventional tracer methods applied to euglycemic-hyperinsulinemic glucose clamps result in substantially negative estimates for the rate of endogenous glucose production, particularly during the first half of 180-min clamps. We also showed that addition of tracer to the exogenous glucose infusate resulted in nonnegative endogenous glucose production (Ra) estimates. In this study, we investigated the underlying cause of negative estimates of Ra from conventional clamp/tracer methods and the reason for the difference in estimates when tracer is added to the exogenous glucose infusate. We performed euglycemic-hyperinsulinemic (300-microU/ml) clamps in normal dogs without (cold GINF protocol, n = 6) or with (hot GINF protocol, n = 6) tracer (D-[3-3H]glucose) added to the exogenous glucose infusate. In the hot GINF protocol, sufficient tracer was added to the exogenous glucose infusate such that arterial plasma specific activity (SAa) did not change from basal through the clamp period (P greater than .05). In the cold GINF studies, plasma SAa fell 81 +/- 2% from the basal level by the 3rd h of clamping. We observed a significant, transient, positive venous-arterial difference in specific activity (SAv-SAa difference) during the cold GINF studies. The SAv-SAa difference reached a peak of 27 +/- 6% at 30 min and diminished to a plateau of 7 +/- 1% between 70 and 180 min. We also observed a positive but constant SAv-SAa difference (4.6 +/- 0.2% between 10 and 180 min) during the hot GINF studies

  15. Inertial piezoelectric linear motor driven by a single-phase harmonic wave with automatic clamping mechanism

    Science.gov (United States)

    He, Liangguo; Chu, Yuheng; Hao, Sai; Zhao, Xiaoyong; Dong, Yuge; Wang, Yong

    2018-05-01

    A novel, single-phase, harmonic-driven, inertial piezoelectric linear motor using an automatic clamping mechanism was designed, fabricated, and tested to reduce the sliding friction and simplify the drive mechanism and power supply control of the inertial motor. A piezoelectric bimorph and a flexible hinge were connected in series to form the automatic clamping mechanism. The automatic clamping mechanism was used as the driving and clamping elements. A dynamic simulation by Simulink was performed to prove the feasibility of the motor. The finite element method software COMSOL was used to design the structure of the motor. An experimental setup was built to validate the working principle and evaluate the performance of the motor. The prototype motor outputted a no-load velocity of 3.178 mm/s at a voltage of 220 Vp-p and a maximum traction force of 4.25 N under a preload force of 8 N. The minimum resolution of 1.14 μm was achieved at a driving frequency of 74 Hz, a driving voltage of 50 Vp-p, and a preload force of 0 N.

  16. Safety of minimally invasive mitral valve surgery without aortic cross-clamp.

    Science.gov (United States)

    Umakanthan, Ramanan; Leacche, Marzia; Petracek, Michael R; Kumar, Sathappan; Solenkova, Nataliya V; Kaiser, Clayton A; Greelish, James P; Balaguer, Jorge M; Ahmad, Rashid M; Ball, Stephen K; Hoff, Steven J; Absi, Tarek S; Kim, Betty S; Byrne, John G

    2008-05-01

    We developed a technique for open heart surgery through a small (5 cm) right-anterolateral thoracotomy without aortic cross-clamp. One hundred and ninety-five consecutive patients (103 male and 92 female), age 69 +/- 8 years, underwent surgery between January 2006 and July 2007. Mean preoperative New York Heart Association function class was 2.2 +/- 0.7. Thirty-five patients (18%) had an ejection fraction 0.35 or less. Cardiopulmonary bypass was instituted through femoral (176 of 195, 90%), axillary (18 of 195, 9%), or direct aortic (1 of 195, 0.5%) cannulation. Under cold fibrillatory arrest (mean temperature 28.2 degrees C) without aortic cross-clamp, mitral valve repair (72 of 195, 37%), mitral valve replacement (117 of 195, 60%), or other (6 of 195, 3%) procedures were performed. Concomitant procedures included maze (45 of 195, 23%), patent foramen ovale closure (42 of 195, 22%) and tricuspid valve repair (16 of 195, 8%), or replacement (4 of 195, 2%). Thirty-day mortality was 3% (6 of 195). Duration of fibrillatory arrest, cardiopulmonary bypass, and "skin to skin" surgery were 88 +/- 32, 118 +/- 52, and 280 +/- 78 minutes, respectively. Ten patients (5%) underwent reexploration for bleeding and 44% did not receive any blood transfusions. Six patients (3%) sustained a postoperative stroke, eight (4%) developed low cardiac output syndrome, and two (1%) developed renal failure requiring hemodialysis. Mean length of hospital stay was 7 +/- 4.8 days. This simplified technique of minimally invasive open heart surgery is safe and easily reproducible. Fibrillatory arrest without aortic cross-clamping, with coronary perfusion against an intact aortic valve, does not increase the risk of stroke or low cardiac output. It may be particularly useful in higher risk patients in whom sternotomy with aortic clamping is less desirable.

  17. Axially Modulated Clamped-Guided Arch Resonator for Memory and Logic Applications

    KAUST Repository

    Hafiz, Md Abdullah Al; Tella, Sherif Adekunle; Alcheikh, Nouha; Fariborzi, Hossein; Younis, Mohammad I.

    2017-01-01

    We experimentally demonstrate memory and logic devices based on an axially modulated clamped-guided arch resonator. The device are electrostatically actuated and capacitively sensed, while the resonance frequency modulation is achieved through an axial electrostatic force from the guided side of the clamped-guided arch microbeam. We present two case studies: first, a dynamic memory based on the nonlinear frequency response of the resonator, and second, a reprogrammable two-input logic gate based on the linear frequency modulation of the resonator. These devices show energy cost per memory/logic operation in pJ, are fully compatible with CMOS fabrication processes, have the potential for on-chip system integration, and operate at room temperature.

  18. Axially Modulated Clamped-Guided Arch Resonator for Memory and Logic Applications

    KAUST Repository

    Hafiz, Md Abdullah Al

    2017-11-03

    We experimentally demonstrate memory and logic devices based on an axially modulated clamped-guided arch resonator. The device are electrostatically actuated and capacitively sensed, while the resonance frequency modulation is achieved through an axial electrostatic force from the guided side of the clamped-guided arch microbeam. We present two case studies: first, a dynamic memory based on the nonlinear frequency response of the resonator, and second, a reprogrammable two-input logic gate based on the linear frequency modulation of the resonator. These devices show energy cost per memory/logic operation in pJ, are fully compatible with CMOS fabrication processes, have the potential for on-chip system integration, and operate at room temperature.

  19. Integral transform solution of bending problem of clamped orthotropic rectangular plates

    International Nuclear Information System (INIS)

    An, C.; Gu, J.-J.; Su, J.

    2011-01-01

    The generalized integral transform technique (GITT) is employed to obtain an exact solution for the bending problem of fully clamped orthotropic rectangular plates. The use of the GITT approach in the analysis of the transverse deflection equation leads to a coupled system of fourth order differential equations in the dimensionless longitudinal spatial variable. The resulting transformed ODE system is then numerically solved by making use of the subroutine DBVPFD from IMSL Library. Numerical results with automatic global accuracy control are produced for different values of aspect ratio. Critical comparisons with previously reported numerical results are performed with excellent agreement. Several sets of reference results for clamped orthotropic rectangular plates are also provided for future covalidation purposes. (author)

  20. Gigaseal formation in patch clamping with applications of nanotechnology

    CERN Document Server

    Malboubi, Majid

    2014-01-01

    This book presents an investigation of gigaseal formation using micro/nanotechnology. The aims of the book are twofold. First, it explains the mechanisms of gigaseal formation using the latest discoveries. Second, it provides practical techniques for frequent formation of high resistance seals. The formation of a high-resistance electrical seal, also known as a gigaseal, between a cell membrane and a glass micropipette tip is essential in patch-clamp experiments. Even though four decades have passed since the introduction of the patch-clamping technique by Neher and Sakmann, gigaseal formation remains an obstacle in developing the high-throughput ion channel screening systems required by the pharmaceutical industry. Here the authors share their latest methods for achieving gigaseal formation and describe techniques that are highly desirable at both research and industrial levels. Nanotechnology has been found to be a powerful tool for studying and modifying glass micropipettes and in tackling the problem of g...

  1. Knowledge-based decision support for Space Station assembly sequence planning

    Science.gov (United States)

    1991-04-01

    A complete Personal Analysis Assistant (PAA) for Space Station Freedom (SSF) assembly sequence planning consists of three software components: the system infrastructure, intra-flight value added, and inter-flight value added. The system infrastructure is the substrate on which software elements providing inter-flight and intra-flight value-added functionality are built. It provides the capability for building representations of assembly sequence plans and specification of constraints and analysis options. Intra-flight value-added provides functionality that will, given the manifest for each flight, define cargo elements, place them in the National Space Transportation System (NSTS) cargo bay, compute performance measure values, and identify violated constraints. Inter-flight value-added provides functionality that will, given major milestone dates and capability requirements, determine the number and dates of required flights and develop a manifest for each flight. The current project is Phase 1 of a projected two phase program and delivers the system infrastructure. Intra- and inter-flight value-added were to be developed in Phase 2, which has not been funded. Based on experience derived from hundreds of projects conducted over the past seven years, ISX developed an Intelligent Systems Engineering (ISE) methodology that combines the methods of systems engineering and knowledge engineering to meet the special systems development requirements posed by intelligent systems, systems that blend artificial intelligence and other advanced technologies with more conventional computing technologies. The ISE methodology defines a phased program process that begins with an application assessment designed to provide a preliminary determination of the relative technical risks and payoffs associated with a potential application, and then moves through requirements analysis, system design, and development.

  2. 47 CFR 97.207 - Space station.

    Science.gov (United States)

    2010-10-01

    ... FCC. (c) The following frequency bands and segments are authorized to space stations: (1) The 17 m, 15... notifications to the International Bureau, FCC, Washington, DC 20554. (1) A pre-space notification within 30... risk of collision and a description of what measures the space station operator plans to take to avoid...

  3. Automated patch clamp on mESC-derived cardiomyocytes for cardiotoxicity prediction.

    Science.gov (United States)

    Stoelzle, Sonja; Haythornthwaite, Alison; Kettenhofen, Ralf; Kolossov, Eugen; Bohlen, Heribert; George, Michael; Brüggemann, Andrea; Fertig, Niels

    2011-09-01

    Cardiovascular side effects are critical in drug development and have frequently led to late-stage project terminations or even drug withdrawal from the market. Physiologically relevant and predictive assays for cardiotoxicity are hence strongly demanded by the pharmaceutical industry. To identify a potential impact of test compounds on ventricular repolarization, typically a variety of ion channels in diverse heterologously expressing cells have to be investigated. Similar to primary cells, in vitro-generated stem cell-derived cardiomyocytes simultaneously express cardiac ion channels. Thus, they more accurately represent the native situation compared with cell lines overexpressing only a single type of ion channel. The aim of this study was to determine if stem cell-derived cardiomyocytes are suited for use in an automated patch clamp system. The authors show recordings of cardiac ion currents as well as action potential recordings in readily available stem cell-derived cardiomyocytes. Besides monitoring inhibitory effects of reference compounds on typical cardiac ion currents, the authors revealed for the first time drug-induced modulation of cardiac action potentials in an automated patch clamp system. The combination of an in vitro cardiac cell model with higher throughput patch clamp screening technology allows for a cost-effective cardiotoxicity prediction in a physiologically relevant cell system.

  4. Principle simulator for a PWR nuclear power station

    International Nuclear Information System (INIS)

    Wahlstroem, B.

    1975-05-01

    A report is given on a simulator developed for the training of operational and planning staff for the Lovisa nuclear power station in Finland. All main components of the power station are illustrated and trainees can operate the simulator in the power range 3-100 %. The model was originally developed for planning the control system of Lovisa I, for which reason the simulator project could be carried out on a relatively limited budget. (author)

  5. Flange joint system for SRF cavities utilizing high force spring clamps for low particle generation

    Science.gov (United States)

    None

    2017-09-05

    A flange joint system for SRF cavities. The flange joint system includes a set of high force spring clamps that produce high force on the simple flanges of Superconducting Radio Frequency (SRF) cavities to squeeze conventional metallic seals. The system establishes the required vacuum and RF-tight seal with minimum particle contamination to the inside of the cavity assembly. The spring clamps are designed to stay within their elastic range while being forced open enough to mount over the flange pair. Upon release, the clamps have enough force to plastically deform metallic seal surfaces and continue to a new equilibrium sprung dimension where the flanges remain held against one another with enough preload such that normal handling will not break the seal.

  6. Transmit Power Minimization and Base Station Planning for High-Speed Trains with Multiple Moving Relays in OFDMA Systems

    KAUST Repository

    Ghazzai, Hakim

    2016-03-15

    High-speed railway system equipped with moving relay stations placed on the middle of the ceiling of each train wagon is investigated. The users inside the train are served in two hops via the orthogonal frequency-division multiple access (OFDMA) technology. In this work, we first focus on minimizing the total downlink power consumption of the base station (BS) and the moving relays while respecting specific quality of service (QoS) constraints. We first derive the optimal resource allocation solution in terms of OFDMA subcarriers and power allocation using the dual decomposition method. Then, we propose an efficient algorithm based on the Hungarian method in order to find a suboptimal but low complexity solution. Moreover, we propose an OFDMA planning solution for high-speed train by finding the maximal inter-BS distance given the required user data rates in order to perform seamless handover. Our simulation results illustrate the performance of the proposed resource allocation schemes in the case of the 3GPP Long Term Evolution-Advanced (LTE-A) and compare them with previously developed algorithms as well as with the direct transmission scenario. Our results also highlight the significant planning gain obtained thanks to the use of multiple relays instead of the conventional single relay scenario.

  7. Stages in planning and construction of the Muelheim-Kaerlich nuclear power station

    International Nuclear Information System (INIS)

    Pracht, F.

    1975-01-01

    On October 23, 1972, RWE gave a letter of intent and on January 9, 1973 an order for the construction of a nuclear power plant on a turn-key basis to the consortium of BBC, BBR and Hochtief. The power plant in question was the Muelheim-Kaerlich nuclear power station with a pressurized-water reactor of a gross efficiency of 1,295 MWe. After considerable delay of the project, the first building permit was issued to the builder-owner on January 15, 1975, and the constructional work on the building site started immediately afterwards. As the planning and constructional work has so far been carried out according to schedule and the consortium intends to keep the effects of the belated license as small as possible, the start-off of the plant will probably be in summer 1979 if the constructional work is not interrupted. (orig./AK) [de

  8. Comparison between symmetrical and asymmetrical single phase multilevel inverter with diode-clamped topology

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Nami, A.; Zare, F.

    2008-01-01

    In this paper, a different configuration based on different DC bus voltage for a diode-clamped multilevel inverter has been presented. Two different symmetrical and asymmetrical arrangements of a four-level diode clamped inverters have been compared, in order to find an optimum arrangement...... compared with the conventional four-level inverter and this will lead to the reduction of harmonic content of output voltage. A predictive current control technique has been carried out to verify the viability of new configuration. The advantages of this control method are simplicity and applicability...

  9. JERS-1 Workshop on the Ground Station for ASEAN

    Science.gov (United States)

    Peanvijarnpong, Chanchai

    1990-11-01

    Presented in viewgraph format, the present status of the ground station and future plan for utilizing earth observation satellites in Thailand is outlined. Topics addressed include: data acquisition system; operation status of LANDSAT, SPOT, and MOS-1 (Marine Observation Satellite-1); remote sensors of satellites; data output form; data correction level; data system in Thailand; ground station for MOS-1 satellite in Thailand; and future plan.

  10. Applicability of fiber model in seismic response analysis for center-clamp type bushings on transformers

    International Nuclear Information System (INIS)

    Miyagawa, Yoshinori; Sato, Hiroaki

    2015-01-01

    A bushing is a device for insulation and support of a conductor. Especially it is called center-clamp type when it is connected with a metal holder through clamping force. As a consequence of damage of center-clamp type bushings in Tohoku Earthquake in 2011, refinement of the response analysis method and review of the seismic design procedure became necessary. In the present report, the fiber model, which can evaluate non-linear behavior in the section subjected to axial force and bending moment, was implemented to the CRIEPI's finite element analysis program 'Mastrd' considering following characteristics of center-clamp type bushings. a) The gasket section between a porcelain tube and a metal holder has a torus shape. b) Springs around the top of the bushing give clamping force, but they lock in excessive base rotation. c) The gasket does not resist against tension. d) Local resistance against compression due to bending increases in use of very thin gaskets. The developed program was verified through comparison with the shaking table test result for real bushings whose voltage classes were 154 kV and 275 kV. Deformation indices as rotation angle and base opening due to bending were influenced by damping conditions. Though there was not the condition which brought about remarkable underestimation, reduction of damping for a fiber model element was preferable for safety. On the other hand, bending moment was consistent with experimental results because it tended not to fluctuate in the non-linear region. (author)

  11. Euglycemic clamp insulin sensitivity and longitudinal systolic blood pressure

    DEFF Research Database (Denmark)

    Petrie, John R; Malik, Muhammad Omar; Balkau, Beverley

    2013-01-01

    and Cardiovascular disease (RISC) study, we measured insulin sensitivity (M/I) using the euglycemic clamp technique in 1073 healthy European adults (587 women, 486 men) aged 30 to 60 years followed up 3 years later. Systolic BP (SBP) at baseline was higher in insulin-resistant women (ie, those in the low sex...

  12. An accurate online calibration system based on combined clamp-shape coil for high voltage electronic current transformers

    International Nuclear Information System (INIS)

    Li, Zhen-hua; Li, Hong-bin; Zhang, Zhi

    2013-01-01

    Electronic transformers are widely used in power systems because of their wide bandwidth and good transient performance. However, as an emerging technology, the failure rate of electronic transformers is higher than that of traditional transformers. As a result, the calibration period needs to be shortened. Traditional calibration methods require the power of transmission line be cut off, which results in complicated operation and power off loss. This paper proposes an online calibration system which can calibrate electronic current transformers without power off. In this work, the high accuracy standard current transformer and online operation method are the key techniques. Based on the clamp-shape iron-core coil and clamp-shape air-core coil, a combined clamp-shape coil is designed as the standard current transformer. By analyzing the output characteristics of the two coils, the combined clamp-shape coil can achieve verification of the accuracy. So the accuracy of the online calibration system can be guaranteed. Moreover, by employing the earth potential working method and using two insulating rods to connect the combined clamp-shape coil to the high voltage bus, the operation becomes simple and safe. Tests in China National Center for High Voltage Measurement and field experiments show that the proposed system has a high accuracy of up to 0.05 class

  13. An accurate online calibration system based on combined clamp-shape coil for high voltage electronic current transformers.

    Science.gov (United States)

    Li, Zhen-hua; Li, Hong-bin; Zhang, Zhi

    2013-07-01

    Electronic transformers are widely used in power systems because of their wide bandwidth and good transient performance. However, as an emerging technology, the failure rate of electronic transformers is higher than that of traditional transformers. As a result, the calibration period needs to be shortened. Traditional calibration methods require the power of transmission line be cut off, which results in complicated operation and power off loss. This paper proposes an online calibration system which can calibrate electronic current transformers without power off. In this work, the high accuracy standard current transformer and online operation method are the key techniques. Based on the clamp-shape iron-core coil and clamp-shape air-core coil, a combined clamp-shape coil is designed as the standard current transformer. By analyzing the output characteristics of the two coils, the combined clamp-shape coil can achieve verification of the accuracy. So the accuracy of the online calibration system can be guaranteed. Moreover, by employing the earth potential working method and using two insulating rods to connect the combined clamp-shape coil to the high voltage bus, the operation becomes simple and safe. Tests in China National Center for High Voltage Measurement and field experiments show that the proposed system has a high accuracy of up to 0.05 class.

  14. Estimates for lower order eigenvalues of a clamped plate problem

    OpenAIRE

    Cheng, Qing-Ming; Huang, Guangyue; Wei, Guoxin

    2009-01-01

    For a bounded domain $\\Omega$ in a complete Riemannian manifold $M^n$, we study estimates for lower order eigenvalues of a clamped plate problem. We obtain universal inequalities for lower order eigenvalues. We would like to remark that our results are sharp.

  15. 33 CFR 183.532 - Clips, straps, and hose clamps.

    Science.gov (United States)

    2010-07-01

    ... resistant material; and (2) Not cut or abrade the fuel line. (b) If tested in accordance with the fire test under § 183.590, a hose clamp installed on a fuel line system requiring metallic fuel lines or “USCG... (CONTINUED) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.532 Clips...

  16. Safety distances for hydrogen filling stations

    NARCIS (Netherlands)

    Matthijsen, A J C M; Kooi, E S

    2006-01-01

    In the context of spatial planning the Dutch Ministry of Housing, Spatial Planning and the Environment asked the Centre for External Safety of the National Institute for Public Health and the Environment (RIVM) to advice on safe distances pertaining to hydrogen filling stations. The RIVM made use of

  17. 40 CFR 52.1080 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... Stations (PAMS) Program. 52.1080 Section 52.1080 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.1080 Photochemical Assessment Monitoring Stations (PAMS) Program. On March 24, 1994 Maryland's... Assessment Monitoring Stations (PAMS) Program as a state implementation plan (SIP) revision, as required by...

  18. 40 CFR 52.2426 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... Stations (PAMS) Program. 52.2426 Section 52.2426 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2426 Photochemical Assessment Monitoring Stations (PAMS) Program. On November 23, 1994 Virginia's... Photochemical Assessment Monitoring Stations (PAMS) Program as a state implementation plan (SIP) revision, as...

  19. Role of clamping tube thoracostomy prior to removal in non-cardiac thoracic trauma

    International Nuclear Information System (INIS)

    Rasheed, M.A.; Majeed, F.A.; Naz, A.

    2016-01-01

    The frequently encountered thoracic trauma in surgical emergencies is a major cause of mortality and morbidity. Eighty percent of thoracic trauma can be managed by simple insertion of tube thoracostomy. Though guidelines for insertion are comprehensively explained in literature, an ideal algorithm for discontinuation is not available. A standard and safe defined protocol would eliminate hesitancy in confident removal among general surgeons. The objective of this study was to determine role of clamping trial prior to removal in terms of frequency of recurrent pneumothorax. Methods: This study was conducted in department of Surgery Combined military hospital/Military Hospital Rawalpindi from April 2013 to March 2014. Total 180 patients with blunt or penetrating thoracic trauma were included in the study. Chest tube (28-36 Fr) was inserted in Trauma centre under strict asepsis. Tubes were then connected to under water seal for minimum six hours. Patients were randomly divided in two equal groups (90 in each). In Group A, Clamping trial was given before attempting removal while in Group B, tube was removed immediately without clamping trial. Patients of both groups were observed two hourly for development of recurrent pneumothorax. Data was analysed using SPSS-18. Results: The comparison of frequency of recurrent pneumothorax in Group A (9 patients, 10%) and in Group B (4 patients, 4.5%) was not found to be statistically significant. (p-value 2.073). Conclusion: Clamping trial is unnecessary prior to removal of tube thoracostomy in blunt and penetrating non-cardiac thoracic trauma in terms of recurrent pneumothorax. (author)

  20. Mycobacterium tuberculosis class II apurinic/apyrimidinic-endonuclease/3'-5' exonuclease III exhibits DNA regulated modes of interaction with the sliding DNA β-clamp.

    Science.gov (United States)

    Khanam, Taran; Rai, Niyati; Ramachandran, Ravishankar

    2015-10-01

    The class-II AP-endonuclease (XthA) acts on abasic sites of damaged DNA in bacterial base excision repair. We identified that the sliding DNA β-clamp forms in vivo and in vitro complexes with XthA in Mycobacterium tuberculosis. A novel 239 QLRFPKK245 motif in the DNA-binding domain of XthA was found to be important for the interactions. Likewise, the peptide binding-groove (PBG) and the C-terminal of β-clamp located on different domains interact with XthA. The β-clamp-XthA complex can be disrupted by clamp binding peptides and also by a specific bacterial clamp inhibitor that binds at the PBG. We also identified that β-clamp stimulates the activities of XthA primarily by increasing its affinity for the substrate and its processivity. Additionally, loading of the β-clamp onto DNA is required for activity stimulation. A reduction in XthA activity stimulation was observed in the presence of β-clamp binding peptides supporting that direct interactions between the proteins are necessary to cause stimulation. Finally, we found that in the absence of DNA, the PBG located on the second domain of the β-clamp is important for interactions with XthA, while the C-terminal domain predominantly mediates functional interactions in the substrate's presence. © 2015 John Wiley & Sons Ltd.

  1. The Effect of PRGF on Healing of Clamp-Induced Tendinopathy in Animals

    Directory of Open Access Journals (Sweden)

    Uğur Diliçıkık

    2018-04-01

    Material and Methods: A preliminary study was designed to obtain more apparent tendinopathy changes in the subculture. Histopathologically, second level compression with a clamp for 1 minute followed by releasing for 3 minutes applying the same mechanical stimulus procedure for four times, was defined as the optimal compression mode for the most optimal damage in terms of tendinopathy. Thirty-four female Sprague Downey type rats were divided into five separate groups and clamped tendon damage was formed on unilateral (left Acchilles tendons. The first group was a control group (Kontrol: CN; in the second group tissue specimens were taken from the rats immediately after being clamped (K-0; from the group 3, tissue samples were taken 1 week after clamping (K-7. Immediately after the tendinopathy model was applied to the animals in the fourth group (PRGF, the PRGF injection was performed to the subjects from the blood that was obtained from the control group, while an isotonic saline solution was injected into the subjects in the fifth group (SF, and tissue samples from both groups were obtained 1 week after. Results: The samples were examined by means of a transmission electron microscope. In the K-0 group among the collagenous fibers, vacuoles are observed in the cytoplasm of the edematous areas and fibrocytes, and in comparison, with K-7 and SF group there was a significant increase in fibroblast and collagen fiber synthesis in the PRGF-treated group. Furthermore, fibroblast and new collagen synthesis were observed to be increased in K-7 and SF groups. An intense increase in organelle levels was observed in PRGF group fibroblasts. Conclusion: This data suggests that PRGF may provide a better healing response in tendons with limited healing and circulation, which enhances the activation in the cells at the beginning of the healing process.

  2. Outside-out "sniffer-patch" clamp technique for in situ measures of neurotransmitter release.

    Science.gov (United States)

    Muller-Chrétien, Emilie

    2014-01-01

    The mechanism underlying neurotransmitter release is a critical research domain for the understanding of neuronal network function; however, few techniques are available for the direct detection and measurement of neurotransmitter release. To date, the sniffer-patch clamp technique is mainly used to investigate these mechanisms from individual cultured cells. In this study, we propose to adapt the sniffer-patch clamp technique to in situ detection of neurosecretion. Using outside-out patches from donor cells as specific biosensors plunged in acute cerebral slices, this technique allows for proper detection and quantification of neurotransmitter release at the level of the neuronal network.

  3. Scanning electron microscope/energy dispersive x ray analysis of impact residues on LDEF tray clamps

    Science.gov (United States)

    Bernhard, Ronald P.; Durin, Christian; Zolensky, Michael E.

    1992-01-01

    To better understand the nature of particulates in low-Earth orbit (LEO), and their effects on spacecraft hardware, we are analyzing residues found in impacts on the Long Duration Exposure Facility (LDEF) tray clamps. LDEF experiment trays were held in place by 6 to 8 chromic-anodized aluminum (6061-T6) clamps that were fastened to the spacecraft frame using three stainless steel hex bolts. Each clamp exposed an area of approximately 58 sq cm (4.8 cm x 12.7 cm x .45 cm, minus the bolt coverage). Some 337 out of 774 LDEF tray clamps were archived at JSC and are available through the Meteoroid & Debris Special Investigation Group (M&D SIG). Optical scanning of clamps, starting with Bay/Row A01 and working toward H25, is being conducted at JSC to locate and document impacts as small as 40 microns. These impacts are then inspected by Scanning Electron Microscopy/Energy Dispersive X-ray Analysis (SEM/EDXA) to select those features which contain appreciable impact residue material. Based upon the composition of projectile remnants, and using criteria developed at JSC, we have made a preliminary discrimination between micrometeoroid and space debris residue-containing impact features. Presently, 13 impacts containing significant amounts of unmelted and semi-melted micrometeoritic residues were forwarded to Centre National d'Etudes Spatiales (CNES) in France. At the CNES facilities, the upgraded impacts were analyzed using a JEOL T330A SEM equipped with a NORAN Instruments, Voyager X-ray Analyzer. All residues were quantitatively characterized by composition (including oxygen and carbon) to help understand interplanetary dust as possibly being derived from comets and asteroids.

  4. NASA space station automation: AI-based technology review

    Science.gov (United States)

    Firschein, O.; Georgeff, M. P.; Park, W.; Neumann, P.; Kautz, W. H.; Levitt, K. N.; Rom, R. J.; Poggio, A. A.

    1985-01-01

    Research and Development projects in automation for the Space Station are discussed. Artificial Intelligence (AI) based automation technologies are planned to enhance crew safety through reduced need for EVA, increase crew productivity through the reduction of routine operations, increase space station autonomy, and augment space station capability through the use of teleoperation and robotics. AI technology will also be developed for the servicing of satellites at the Space Station, system monitoring and diagnosis, space manufacturing, and the assembly of large space structures.

  5. Biological cell controllable patch-clamp microchip

    Science.gov (United States)

    Penmetsa, Siva; Nagrajan, Krithika; Gong, Zhongcheng; Mills, David; Que, Long

    2010-12-01

    A patch-clamp (PC) microchip with cell sorting and positioning functions is reported, which can avoid drawbacks of random cell selection or positioning for a PC microchip. The cell sorting and positioning are enabled by air bubble (AB) actuators. AB actuators are pneumatic actuators, in which air pressure is generated by microheaters within sealed microchambers. The sorting, positioning, and capturing of 3T3 cells by this type of microchip have been demonstrated. Using human breast cancer cells MDA-MB-231 as the model, experiments have been demonstrated by this microchip as a label-free technical platform for real-time monitoring of the cell viability.

  6. Evolutionary growth for Space Station Freedom electrical power system

    Science.gov (United States)

    Marshall, Matthew Fisk; Mclallin, Kerry; Zernic, Mike

    1989-01-01

    Over an operational lifetime of at least 30 yr, Space Station Freedom will encounter increased Space Station user requirements and advancing technologies. The Space Station electrical power system is designed with the flexibility to accommodate these emerging technologies and expert systems and is being designed with the necessary software hooks and hardware scars to accommodate increased growth demand. The electrical power system is planned to grow from the initial 75 kW up to 300 kW. The Phase 1 station will utilize photovoltaic arrays to produce the electrical power; however, for growth to 300 kW, solar dynamic power modules will be utilized. Pairs of 25 kW solar dynamic power modules will be added to the station to reach the power growth level. The addition of solar dynamic power in the growth phase places constraints in the initial Space Station systems such as guidance, navigation, and control, external thermal, truss structural stiffness, computational capabilities and storage, which must be planned-in, in order to facilitate the addition of the solar dynamic modules.

  7. Analysis of failed and nickel-coated 3093 beam clamp components at the East Tennessee Technology Park (ETTP).

    Energy Technology Data Exchange (ETDEWEB)

    Singh, D.; Pappacena, K.; Gaviria, J.; Burtsteva, T.; Nuclear Engineering Division

    2010-10-11

    The U.S. Department of Energy and its contractor, Bechtel Jacobs Company (BJC), are undertaking a major effort to clean up the former gaseous diffusion facility (K-25) located in Oak Ridge, TN. The decontamination and decommissioning activities require systematic removal of contaminated equipment and machinery followed by demolition of the buildings. As part of the cleanup activities, a beam clamp, used for horizontal life lines (HLLs) for fall protection, was discovered to be fractured during routine inspection. The beam clamp (yoke and D-ring) was a component in the HLL system purchased from Reliance Industries LLC. Specifically, the U-shaped stainless steel yoke of the beam clamp failed in a brittle mode at under less than 10% of the rated design capacity of 14,500 lb. The beam clamp had been in service for approximately 16 months. Bechtel Jacobs approached Argonne National Laboratory to assist in identifying the root cause of the failure of the beam clamp. The objectives of this study were to (1) review the prior reports and documents on the subject, (2) understand the possible failure mechanism(s) that resulted in the failed beam clamp components, (3) recommend approaches to mitigate the failure mechanism(s), and (4) evaluate the modified beam clamp assemblies. Energy dispersive x-ray analysis and chemical analysis of the corrosion products on the failed yoke and white residue on an in-service yoke indicated the presence of zinc, sulfur, and calcium. Analysis of rainwater in the complex, as conducted by BJC, indicated the presence of sulfur and calcium. It was concluded that, as a result of galvanic corrosion, zinc from the galvanized components of the beam clamp assembly (D-ring) migrated to the corroded region in the presence of the rainwater. Under mechanical stress, the corrosion process would have accelerated, resulting in the catastrophic failure of the yoke. As suggested by Bechtel Jacobs personnel, hydrogen embrittlement as a consequence of corrosion

  8. Environmental assessment, proposed generating station for Darlington

    International Nuclear Information System (INIS)

    1975-04-01

    This document indicates the intention of Ontario Hydro to seek approval from the Provincial Government for its plan to construct and operate a 3400 MWe nuclear generating station at the Darlington site, west of Bowmanville. This preliminary proposal also contains the environmental assessment. The environmental section of this proposal describes and assesses the existing environment and the environmental influences which would occur due to the construction and operation of a nuclear generating station, consisting of four 850 MW units, at the Darlington site. This proposed station is similar to the Bruce GS A station presently under construction. (author)

  9. space vector pulse width modulation of a multi-level diode clamped

    African Journals Online (AJOL)

    ES Obe

    step by step development of MATLAB /SIMULINK modeling of the space vector ..... Pulse Width Mod. of Multi-Level Diode Clamped Converter 119 powergui. Discrete, .... Load. Figure 22: Block diagram of the three level DCC design. 3 LEVEL ...

  10. Voltage Balancing Control of Diode-Clamped Multilevel Inverter

    Directory of Open Access Journals (Sweden)

    ŞCHIOP Adrian

    2013-10-01

    Full Text Available In this paper is developed a control scheme for mono-phase diode clamped inverter to achieve balancing voltages on inverter capacitors. First, it develops a control scheme without taking into account the need to balance voltage on two capacitors. It examines the effects on the output voltage inverter, and then it realizes two control schemes that will balance the voltages. The simulations of control schemes were performed in OrCAD Pspice.

  11. Five-level Z-source diode-clamped inverter

    DEFF Research Database (Denmark)

    Gao, F.; Loh, Poh Chiang; Blaabjerg, Frede

    2010-01-01

    This study proposes a five-level Z-source diode-clamped inverter designed with two intermediate Z-source networks connected between the dc input sources and rear-end inverter circuitry. By partially shorting the Z-source networks, new operating states not previously reported for two-level Z......-source inverter are introduced here for operating the proposed inverter with voltage buck–boost energy conversion ability and five-level phase voltage switching. These characteristic features are in fact always ensured at the inverter terminal output by simply adopting a properly designed carrier modulation...

  12. Bingham Sealing and Application in Vacuum Clamping

    Science.gov (United States)

    Yao, S. M.; Teo, Wee Kin; Geng, Zunmin; Turner, Sam; Ridgway, Keith

    2011-12-01

    Vacuum clamping is extensively used in shell machining. In this paper a Bingham Sealing (BS) is presented and formulized based on Bingham plastic performance. The sealing capability of BS is evaluated in various cases. A new Bingham plastic is developed and the yield stress is measured. The performances of "O"ring sealing and BS with the developed Bingham plastic are compared to the static experiment. In this experiment the same vacuum is achieved and the distortion of the blade with BS is better than that with "O" ring sealing.

  13. Bingham Sealing and Application in Vacuum Clamping

    International Nuclear Information System (INIS)

    Yao, S M; Teo, Wee Kin; Geng Zunmin; Turner, Sam; Ridgway, Keith

    2011-01-01

    Vacuum clamping is extensively used in shell machining. In this paper a Bingham Sealing (BS) is presented and formulized based on Bingham plastic performance. The sealing capability of BS is evaluated in various cases. A new Bingham plastic is developed and the yield stress is measured. The performances of Or ing sealing and BS with the developed Bingham plastic are compared to the static experiment. In this experiment the same vacuum is achieved and the distortion of the blade with BS is better than that with 'O' ring sealing.

  14. The hypertriglyceridemic clamp technique. Studies using long-chain and structured triglyceride emulsions in healthy subjects.

    Science.gov (United States)

    Nordenström, Jörgen; Thörne, Anders; Aberg, Wiveca; Carneheim, Claes; Olivecrona, Thomas

    2006-11-01

    In a randomized crossover study, plasma kinetics of 2 different types of fat emulsions were studied in 8 healthy volunteers by using a hypertriglyceridemic clamp technique. The method involves the stabilization of serum triglyceride (TG) concentration during 180 minutes at a predetermined level (4 mmol/L) by adjustment of TG infusion rate by repeated online measurements of serum TG concentration. The fat emulsions under study were a long-chain fatty acid triglyceride (LCT) emulsion (Intralipid 20%, Fresenius Kabi, Sweden) and a structured triglyceride (STG) emulsion (Structolipid 20%, Fresenius Kabi) where medium- and long-chain fatty acids have been interesterified within a TG molecule. The hypertriglyceridemic clamp was found to have acceptable reproducibility when tested in 3 healthy individuals on 2 different occasions, as similar steady-state TG levels were obtained by infusing similar amounts of fat. The average (+/-SEM) TG concentration during the 180-minute clamp was similar for STGs and LCTs (4.0 +/- 0.1 vs 3.9 +/- 0.1 mmol/L; not significant), but the amount of fat that had to be infused was significantly higher during STG than during LCT clamping (0.31 +/- 0.04 vs 0.21 +/- 0.02 g TG per minute; P < .05). Higher serum levels of free fatty acids (1.80 +/- 0.13 vs 0.96 +/- 0.09 mmol/L; P < .05), free glycerol (1.30 +/- 0.07 vs 0.76 +/- 0.08 mmol/L; P < .001), and beta-OH butyrate (1.61 +/- 0.44 vs 1.17 +/- 0.23 mmol/L; not significant) were obtained at the end of the clamp during infusion of STGs compared with LCTs. During infusion of STGs the medium-chain fatty acids octanoic (C:8) and decanoic acid (C:10) constituted approximately half of circulating fatty acids that correspond to the compositional ratio of the emulsion. Plasma lipoprotein lipase (LPL) concentration was higher during STG than during LCT clamping (6.06 +/- 0.62 vs 3.15 +/- 0.40 mU/mL; P < .05), and there was a positive correlation between the mean LPL concentration and the amount of

  15. Optimal Allocation of Changing Station for Electric Vehicle Based on Queuing Theory

    Directory of Open Access Journals (Sweden)

    Yagang Zhang

    2016-11-01

    Full Text Available Electric vehicle as the main development direction of the future automotive industry, has gained attention worldwide. The rationality of the planning and construction of the power station, as the foundation of energy supply, is an important premise for the development of electric vehicles. In full consideration of the electric demand and electricity consumption, this paper proposes a new construction mode in which charging station and centralized charging station are appropriately combined and presents a location optimization model. Not only can this model be applied to determine the appropriate location for the power station, but it can use the queuing theory to determine the optimal number of power equipment, with which we can achieve the minimum costs. Finally, taking a certain city as an example, the optimum plan for power station is calculated by using this model, which provides an important reference for the study of electric vehicle infrastructure planning.

  16. Effects of clamping force on the water transport and performance of a PEM (proton electrolyte membrane) fuel cell with relative humidity and current density

    International Nuclear Information System (INIS)

    Cha, Dowon; Ahn, Jae Hwan; Kim, Hyung Soon; Kim, Yongchan

    2015-01-01

    The clamping force should be applied to a proton electrolyte membrane (PEM) fuel cell due to its structural characteristics. The clamping force affects the ohmic and mass transport resistances in the PEM fuel cell. In this study, the effects of the clamping force on the water transport and performance characteristics of a PEM fuel cell are experimentally investigated with variations in the relative humidity and current density. The water transport characteristics were analyzed by calculating the net drag coefficient. The ohmic resistance decreased with the increase in the clamping force due to the reduced contact resistance and more even membrane hydration. However, the mass transport resistance increased with the increase in the clamping force due to the gas diffusion layer compression. The net drag coefficient decreased with the increase in the clamping force due to high water back-diffusion. Additionally, the relationship between the total resistance and the net drag coefficient was investigated. - Highlights: • Effects of clamping force on the performance of a PEM fuel cell are investigated. • Water transport characteristics are analyzed using net drag coefficient. • Ohmic resistance decreased with clamping force, but mass transport resistance increased. • Net drag coefficient decreased with the increase in clamping force. • Total resistance was significantly degraded for a net drag coefficient below 0.2.

  17. External mean flow influence on sound transmission through finite clamped double-wall sandwich panels

    Science.gov (United States)

    Liu, Yu; Catalan, Jean-Cédric

    2017-09-01

    This paper studies the influence of an external mean flow on the sound transmission through finite clamped double-wall sandwich panels lined with poroelastic materials. Biot's theory is employed to describe wave propagation in poroelastic materials and various configurations of coupling the poroelastic layer to the facing plates are considered. The clamped boundary of finite panels are dealt with by the modal superposition theory and the weighted residual (Garlekin) method, leading to a matrix equation solution for the sound transmission loss (STL) through the structure. The theoretical model is validated against existing theories of infinite sandwich panels with and without an external flow. The numerical results of a single incident wave show that the external mean flow has significant effects on the STL which are coupled with the clamped boundary effect dominating in the low-frequency range. The external mean flow also influences considerably the limiting incidence angle of the panel system and the effect of the incidence angle on the STL. However, the influences of the azimuthal angle and the external flow orientation are negligible.

  18. Isolated PWM DC-AC SICAM with an active capacitive voltage clamp[Pulse Density Modulated; Pulse Width Modulation

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.

    2004-03-15

    In this report an isolated PWM DC-AC SICAM with an active capacitive voltage clamp is presented. AC-DC power supply is implemented in its simplest form: diode rectifier followed by a medium-size charge-storage capacitors and possibly with an EMC filter on the mains entrance. Isolation from the AC mains is achieved using a high frequency (HF) transformer, whose voltages are not audio-modulated. The latter simplifies the design and is expected to have many advantages over the approach where the transformer voltages are modulated in regards to the audio signal reference. Input stage is built as a DC-AC inverter (push-pull, half-bridge or a full-bridge) and operated with 50% duty cycle, with all the challenges to avoid transformer saturation and obtain symmetrical operation. On the secondary side the output section is implemented as rectifier+inverter AC-AC stage, i.e. a true bidirectional bridge, which operation is aimed towards amplification of the audio signal. In order to solve the problem with the commutation of the load current, a dead time between the incoming and outgoing bidirectional switch is implemented, while a capacitive voltage clamp is used to keep the induced overvoltage to reasonable levels. The energy stored in the clamping capacitor is not wasted as in the dissipative clamps, but is rather transferred back to the primary side for further processing using an auxiliary isolated single-switch converter, i.e. an active clamping technique is used. (au)

  19. Analytical and experimental investigation on transmission loss of clamped double panels: implication of boundary effects.

    Science.gov (United States)

    Xin, F X; Lu, T J

    2009-03-01

    The air-borne sound insulation performance of a rectangular double-panel partition clamp mounted on an infinite acoustic rigid baffle is investigated both analytically and experimentally and compared with that of a simply supported one. With the clamped (or simply supported) boundary accounted for by using the method of modal function, a double series solution for the sound transmission loss (STL) of the structure is obtained by employing the weighted residual (Galerkin) method. Experimental measurements with Al double-panel partitions having air cavity are subsequently carried out to validate the theoretical model for both types of the boundary condition, and good overall agreement is achieved. A consistency check of the two different models (based separately on clamped modal function and simply supported modal function) is performed by extending the panel dimensions to infinite where no boundaries exist. The significant discrepancies between the two different boundary conditions are demonstrated in terms of the STL versus frequency plots as well as the panel deflection mode shapes.

  20. NASA space station automation: AI-based technology review. Executive summary

    Science.gov (United States)

    Firschein, O.; Georgeff, M. P.; Park, W.; Cheeseman, P. C.; Goldberg, J.; Neumann, P.; Kautz, W. H.; Levitt, K. N.; Rom, R. J.; Poggio, A. A.

    1985-01-01

    Research and Development projects in automation technology for the Space Station are described. Artificial Intelligence (AI) based technologies are planned to enhance crew safety through reduced need for EVA, increase crew productivity through the reduction of routine operations, increase space station autonomy, and augment space station capability through the use of teleoperation and robotics.

  1. Robust Clamping Force Control of an Electro-Mechanical Brake System for Application to Commercial City Buses

    Directory of Open Access Journals (Sweden)

    Sangjune Eum

    2017-02-01

    Full Text Available This paper proposes a sensor-less robust force control method for improving the control performance of an electro-mechanical brake (EMB which is applicable to commercial city buses. The EMB generates the accurate clamping force commanded by a driver through an independent motor control at each wheel instead of using existing mechanical components. In general, an EMB undergoes parameter variation and a backdrivability problem. For this reason, the cascade control strategy (e.g., force-position cascade control structure is proposed and the disturbance observer is employed to enhance control robustness against model variations. Additionally, this paper proposed the clamping force estimation method for a sensor-less control, i.e., the clamping force observer (CFO. Finally, in order to confirm the performance and effectiveness of a proposed robust control method, several experiments are performed and analyzed.

  2. Feasibility, safety and image quality of cardiac FDG studies during hyperinsulinaemic-euglycaemic clamping

    International Nuclear Information System (INIS)

    Bax, Jeroen J.; Visser, Frans C.; Lingen, Arthur van; Visser, Cees A.; Poldermans, Don; Elhendy, Abdou; Boersma, Eric

    2002-01-01

    Fluorine-18 fluorodeoxyglucose (FDG) imaging for the assessment of myocardial viability has become an integral part of the diagnostic and prognostic work-up of patients with ischaemic cardiomyopathy. To ensure good image quality, in particular in patients with diabetes mellitus, hyperinsulinaemic-euglycaemic clamping has been proposed. In this study we evaluated the safety and the image quality of cardiac FDG imaging during clamping in a large group of patients, including a subgroup with diabetes mellitus. The incidence of viability (on both a segment and a patient basis) was also determined for patients with and without diabetes mellitus. The safety and image quality of cardiac FDG studies during clamping were evaluated in 131 patients, including 19 with diabetes mellitus. Image quality was assessed visually and quantitatively using heart-to-lung (H/L), heart-to-liver (H/Li) and myocardium-to-background (M/B) ratios. Blood samples were drawn at baseline and at the time of FDG injection to determine levels of glucose, free fatty acids and insulin. The metabolic circumstances were optimal for FDG imaging: high insulin levels, low free fatty acid levels and glucose levels in the normal range (levels of substrates were comparable between patients with and patients without diabetes mellitus). No serious side-effects occurred in any patient. Image quality (assessed visually) was good in all patients. The quantitative parameters of image quality (H/L, H/Li and M/B) were comparable between patients with and patients without diabetes mellitus. The incidence of viability was high: 38% of patients without and 58% of patients with diabetes mellitus had substantial viability despite contractile dysfunction. It is concluded that cardiac FDG imaging during clamping is safe and provides excellent image quality, including in patients with diabetes mellitus. The incidence of viability is high, in particular in patients with diabetes mellitus. (orig.)

  3. Influence of non-steady state during isoglycemic hyperinsulinemic clamp in hypertension. A LIFE substudy

    DEFF Research Database (Denmark)

    Olsen, M H; Andersen, U B; Wachtell, K

    1999-01-01

    We wanted to investigate whether time to steady state was reached within 2 h of insulin infusion during isoglycemic hyperinsulinemic clamp, comparing the glucose uptake index (M/IG) with Bergman's insulin sensitivity index (Sip). We performed a 2-h oral glucose tolerance test and a 3-h isoglycemic....... Because the 2-h M/IG correlated strongly with the 3-h Sip with relatively narrow limits of agreement, it is a good measure of insulin sensitivity. However, a 2-h clamp results in lower insulin sensitivity values in elderly, hypertensive patients due to the fact that steady state is not reached...

  4. Mathematical model for estimating of technical and technological indicators of railway stations operation

    Directory of Open Access Journals (Sweden)

    D.M. Kozachenko

    2013-06-01

    Full Text Available Purpose. The article aims to create a mathematical model of the railway station functioning for the solving of problems of station technology development on the plan-schedule basis. Methodology. The methods of graph theory and object-oriented analysis are used as research methods. The model of the station activity plan-schedule includes a model of technical equipment of the station (plan-schedule net and a model of the station functioning , which are formalized on the basis of parametric graphs. Findings. The presented model is implemented as an application to the graphics package AutoCAD. The software is developed in Visual LISP and Visual Basic. Taking into account that the construction of the plan-schedule is mostly a traditional process of adding, deleting, and modifying of icons, the developed interface is intuitively understandable for a technologist and practically does not require additional training. Originality. A mathematical model was created on the basis of the theory of graphs and object-oriented analysis in order to evaluate the technical and process of railway stations indicators; it is focused on solving problems of technology development of their work. Practical value. The proposed mathematical model is implemented as an application to the graphics package of AutoCAD. The presence of a mathematical model allows carrying out an automatic analysis of the plan-schedule and, thereby, reducing the period of its creation more than twice.

  5. Dynamic characteristics of rotating pretwisted clamped-clamped beam under thermal stress

    International Nuclear Information System (INIS)

    Zhang, Bo; Li, Yueming; Lu, Wei Zhen

    2016-01-01

    Effects of thermal stress on the vibration characteristics, buckling limit and critical speed of a rotating pretwisted beam clamped to rigid hub at a stagger angle were investigated. By considering the work done by thermal stress, the thermal influence on stiffness matrix was introduced in the dynamic model. The motion equations were derived based on Lagrange equation by employing three pure Cartesian deformation variables combined with nonlinear von Karman strain formula. Numerical investigations studied the modal characteristics of the beam. Numerical results calculated from a commercial finite element code and obtained with the present modeling method were in good agreement with the previous results reported in the literature. The combined softening effects due to the thermal stress and the rotation motion were observed. Furthermore, it is shown that the inclusion of thermal stress is necessary for blades operating under a high temperature field. Buckling thermal loads and the critical rotating speed were calculated through solving the corresponding nonlinear equations numerically, and some pertinent conclusions are outlined. It is also found that the peak value position of the first mode shape approaches to the tip of blade with the increment of rotating speed and hub radius. However, the variation in the environment temperature causes only a slight alteration in the mode shape

  6. Dynamic characteristics of rotating pretwisted clamped-clamped beam under thermal stress

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Bo; Li, Yueming [State Key Laboratory for Strength and Vibration of Mechanical Structures, Shaanxi Key Laboratory of Environment and Control for Flight Vehicle, School of Aerospace, Xi' an Jiaotong UniversityXi' an (China); Lu, Wei Zhen [Dept. of Civil and Architectural Engineering, City University of Hong Kong, Hong Kong (China)

    2016-09-15

    Effects of thermal stress on the vibration characteristics, buckling limit and critical speed of a rotating pretwisted beam clamped to rigid hub at a stagger angle were investigated. By considering the work done by thermal stress, the thermal influence on stiffness matrix was introduced in the dynamic model. The motion equations were derived based on Lagrange equation by employing three pure Cartesian deformation variables combined with nonlinear von Karman strain formula. Numerical investigations studied the modal characteristics of the beam. Numerical results calculated from a commercial finite element code and obtained with the present modeling method were in good agreement with the previous results reported in the literature. The combined softening effects due to the thermal stress and the rotation motion were observed. Furthermore, it is shown that the inclusion of thermal stress is necessary for blades operating under a high temperature field. Buckling thermal loads and the critical rotating speed were calculated through solving the corresponding nonlinear equations numerically, and some pertinent conclusions are outlined. It is also found that the peak value position of the first mode shape approaches to the tip of blade with the increment of rotating speed and hub radius. However, the variation in the environment temperature causes only a slight alteration in the mode shape.

  7. Trans-Z-source and Γ-Z-source neutral-point-clamped inverters

    DEFF Research Database (Denmark)

    Wei, Mo; Loh, Poh Chiang; Blaabjerg, Frede

    2015-01-01

    Z-source neutral-point-clamped (NPC) inverters are earlier proposed for obtaining voltage buck-boost and three-level switching simultaneously. Their performances are, however, constrained by a trade-off between their input-to-output gain and modulation ratio. This trade-off can lead to high...

  8. Evaluation of diel patterns of relative changes in cell turgor of tomato plants using leaf patch clamp pressure probes

    NARCIS (Netherlands)

    Lee, K.M.; Driever, S.M.; Heuvelink, E.; Rüger, S.; Zimmermann, U.; Gelder, de A.; Marcelis, L.F.M.

    2012-01-01

    Relative changes in cell turgor of leaves of well-watered tomato plants were evaluated using the leaf patch clamp pressure probe (LPCP) under dynamic greenhouse climate conditions. Leaf patch clamp pressure changes, a measure for relative changes in cell turgor, were monitored at three different

  9. Targeted Endovascular Temporary Vessel Occlusion with a Reverse Thermosensitive Polymer for Near-Bloodless Partial Nephrectomy: Comparison to Standard Surgical Clamping Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Flacke, Sebastian, E-mail: Sebastian.Flacke@lahey.org [Lahey Clinic, Tuft University Medical School, Department of Radiology (United States); Harty, Niall J.; Laskey, Daniel H.; Moinzadeh, Alireza [Lahey Clinic, Tuft University Medical School, Department of Urology (United States); Benn, James A. [Pluromed Inc (United States); Villani, Rosanna [DaVinci Biomedical Research Products (United States); Kalra, Aarti [Lahey Clinic, Tuft University Medical School, Department of Pathology (United States); Libertino, John A.; Madras, Peter N. [Lahey Clinic, Tuft University Medical School, Department of Urology (United States)

    2012-10-15

    Purpose: To determine whether reversible blood flow interruption to a randomly chosen target region of the kidney may be achieved with the injection of a reverse thermoplastic polymer through an angiographic catheter, thereby facilitating partial nephrectomy without compromising blood flow to the remaining kidney or adding risks beyond those encountered by the use of hilar clamping. Methods: Fifteen pigs underwent partial nephrectomy after blood flow interruption by vascular cross-clamping or injection of polymer (Lumagel Trade-Mark-Sign ) into a segmental artery. Five animals were euthanized after surgery (three open and two laparoscopic resection, cross-clamping n = 2), and 10 (open resection, cross-clamping n = 4) were euthanized after 6 weeks' survival. Blood specimens were obtained periodically, and angiogram and necropsy were performed at 6 weeks. Results: Selective renal ischemia was achieved in all cases. Surgical resection time averaged 9 and 24.5 min in the open and laparoscopic groups, respectively. Estimated blood loss was negligible with the exception of one case where an accessory renal artery was originally overlooked. Reversal of the polymer to a liquid state was consistent angiographically and visually in all cases. Time to complete flow return averaged 7.4 and 2 min for polymer and clamping, respectively. Angiography at 6 weeks revealed no evidence of vascular injury. Laboratory data and necropsies revealed no differences between animals undergoing vascular clamping or polymer injection. Conclusion: Lumagel was as effective as vascular clamping in producing a near bloodless operative field for partial nephrectomy while maintaining flow to the uninvolved portion of the affected kidney.

  10. Galileo Station Keeping Strategy

    Science.gov (United States)

    Perez-Cambriles, Antonio; Bejar-Romero, Juan Antonio; Aguilar-Taboada, Daniel; Perez-Lopez, Fernando; Navarro, Daniel

    2007-01-01

    This paper presents analyses done for the design and implementation of the Maneuver Planning software of the Galileo Flight Dynamics Facility. The station keeping requirements of the constellation have been analyzed in order to identify the key parameters to be taken into account in the design and implementation of the software.

  11. Solution study of the Escherichia coli DNA polymerase III clamp loader reveals the location of the dynamic ψχ heterodimer

    Directory of Open Access Journals (Sweden)

    Farzaneh Tondnevis

    2015-09-01

    Full Text Available Several X-ray crystal structures of the E. coli core clamp loader containing the five core (δ′, δ, and three truncated γ subunits have been determined, but they lack the ψ and χ subunits. We report the first solution structure of the complete seven-subunit clamp loader complex using small angle X-ray scattering. This structure not only provides information about the location of the χ and ψ subunits but also provides a model of the dynamic nature of the clamp loader complex.

  12. Design and control of a novel gastroscope intervention mechanism with circumferentially pneumatic-driven clamping function.

    Science.gov (United States)

    Li, Yanmin; Liu, Hao; Hao, Siwen; Li, Hongyi; Han, Jianda; Yang, Yunsheng

    2017-03-01

    Robot-assisted manipulation is promising for solving problems such as understaffing and the risk of infection in gastro-intestinal endoscopy. However, the commonly used friction rollers in few existing systems have a potential risk of deforming flexible endoscopes for non-uniform clamping. This paper presents a robotic system for a standard flexible endoscope and focuses on a novel gastroscope intervention mechanism (GIM), which provides circumferentially uniform clamping with an airbag. The GIM works with a relay-on mechanism in a way similar to manual operation. The shear stiffness of airbag and the critical slipping force (CSF) were analysed to determine the parameters of the airbag. A fuzzy PID controller was employed to realize a fast response and high accuracy of pneumatic actuation. Experiments were performed to evaluate the accuracy, stiffness and CSF. In vitro and in vivo animal experiments were also carried out. The GIM realized an accuracy of 0.025 ± 0.2 mm and -0.03 ± 0.25° for push-pull and rotation without delivery resistance. Under polynomial could be used to describe the relationship between the CSF and pneumatic pressure. The novel GIM could effectively deliver gastroscopes. The pneumatic-driven clamping method proposed could protect the gastroscope by circumferentially uniform clamping force and the CSF could be properly controlled to guarantee operating safety. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. On the development of small nuclear power stations

    International Nuclear Information System (INIS)

    Goetzmann, C.A.

    1989-01-01

    There are weighty reasons for and against the building of small nuclear power stations. Factors such as specific investment costs, opportunities for and areas of application, geographical conditions as well as those relating to infrastructure, security and availability play an important role in the planning, construction and running of a nuclear power station. For the usual large power stations, the comparatively low specific investment costs and a proven technology are favorable factors which minimize the investment risk. The article presents an overview of reasons for using small power stations and also considers the difficulties which would arise in practice. (orig.) [de

  14. Diuretic response to acute hypertension is blunted during angiotensin II clamp

    DEFF Research Database (Denmark)

    Leong, Patrick K K; Zhang, Yibin; Yang, Li E

    2002-01-01

    and endogenous lithium clearance increased two- and threefold, respectively. We conclude that HOE-140, an inhibitor of the B(2) receptor, potentiates the sensitivity of arterial pressure to ANG II and that clamping systemic ANG II levels during acute hypertension blunts the magnitude of the pressure diuretic...

  15. A Hybrid Cascade Converter Topology With Series-Connected Symmetrical and Asymmetrical Diode-Clamped H-Bridge Cells

    DEFF Research Database (Denmark)

    Nami, Alireza; Zare, Firuz; Ghosh, Arindam

    2011-01-01

    to approach a very low total harmonic distortion of voltage and current, which leads to the possible elimination of the output filter. Regarding the proposed configuration, a new cascade inverter is verified by cascading an asymmetrical diode-clamped inverter, in which 19 levels can be synthesized in output......A novel H-bridge multilevel pulsewidth modulation converter topology based on a series connection of a high-voltage diode-clamped inverter and a low-voltage conventional inverter is proposed in this paper. A dc link voltage arrangement for the new hybrid and asymmetric solution is presented to have...... voltage with the same number of components. To balance the dc link capacitor voltages for the maximum output voltage resolution as well as synthesize asymmetrical dc link combination, a new multi-output boost converter is utilized at the dc link voltage of a seven-level H-bridge diode-clamped inverter...

  16. Impedance spectra of patch clamp scenarios for single cells immobilized on a lab-on-a-chip

    DEFF Research Database (Denmark)

    Alberti, Massimo; Snakenborg, Detlef; Lopacinska, Joanna M.

    2014-01-01

    and simulated impedance spectra proved that the presented method could distinguish between a cell-attached mode and a whole-cell mode even with low-quality seals. In physiological conditions, the capacitance of HeLa cells was measured to *38 pF. The first gigaseal was recorded and maintained for 40 min. Once...... membrane. After incubating the chip for 24 h, HeLa cells adhered and grew on the chip surface but did not survive when trapped on the microapertures. The microfluidic system proved to work as a micro electrophysiological analysis system, and the IS-based method can be used for further studies on the post......A simple method based on impedance spectroscopy (IS) was developed to distinguish between different patch clamp modes for single cells trapped on microapertures in a patch clamp microchannel array designed for patch clamping on cultured cells. The method allows detecting via impedance analysis...

  17. Laser microsurgery of higher plant cell walls permits patch-clamp access

    International Nuclear Information System (INIS)

    Henriksen, G.H.; Taylor, A.R.; Brownlee, C.; Assmann, S.M.

    1996-01-01

    Plasma membranes of guard cells in epidermal peels of Vicia faba and Commelina communis can be made accessible to a patch-clamp pipet by removing a small portion (1-3 micrometer in diameter) of the guard cell wall using a microbeam of ultraviolet light generated by a nitrogen laser. Using this laser microsurgical technique, we have measured channel activity across plasma membranes of V. faba guard cells in both cell-attached and isolated patch configurations. Measurements made in the inside-out patch configuration revealed two distinct K+-selective channels. Major advantages of the laser microsurgical technique include the avoidance of enzymatic protoplast isolation, the ability to study cell types that have been difficult to isolate as protoplasts or for which enzymatic isolation protocols result in protoplasts not amenable to patch-clamp studies, the maintenance of positional information in single-channel measurements, reduced disruption of cell-wall-mediated signaling pathways, and the ability to investigate intercellular signaling through studies of cells remaining situated within tissue

  18. Hinkley Point 'C' power station public inquiry: statement of case

    International Nuclear Information System (INIS)

    1988-08-01

    This Statement of Case contains full particulars of the case which the Central Electricity Generating Board (CEGB) proposes to put forward at the Hinkley Point ''C'' Inquiry. It relates to the planning application made by the CEGB for the construction of a 1200 MW Pressurized Water Reactor (PWR) power station at Hinkley Point in the United Kingdom, adjacent to an existing nuclear power station. The inquiry will consider economic, safety, environmental and planning matters relevant to the application and the implications for agriculture and local amenities of re-aligning two power transmission lines. The Statement contains submissions on the following matters: Topic 1 The Requirement for the Station; Topic 2 Safety and Design, including Radioactive Discharges; Topic 3 The On-Site Management of Radioactive Waste and Decommissioning of the Station; Topic 4 Emergency Arrangements; Topic 5 Local and Environmental Issues. (author)

  19. Local society and nuclear power stations

    International Nuclear Information System (INIS)

    1984-02-01

    This report was made by the expert committee on region investigation, Japan Atomic Industrial Forum Inc., in fiscal years 1981 and 1982 in order to grasp the social economic influence exerted on regions by the location of nuclear power stations and the actual state of the change due to it, and to search for the way the promotion of local community should be. The influence and the effect were measured in the regions around the Fukushima No. 1 Nuclear Power Station of Tokyo Electric Power Co., Inc., the Mihama Power Station of Kansai Electric Power Co., Inc., and the Genkai Nuclear Power Station of Kyushu Electric Power Co., Inc. The fundamental recognition in this discussion, the policy of locating nuclear power stations and the management of regions, the viewpoint and way of thinking in the investigation of the regions where nuclear power stations are located, the actual state of social economic impact due to the location of nuclear power stations, the connected mechanism accompanying the location of nuclear power stations, and the location of nuclear power stations and the acceleration of planning for regional promotion are reported. In order to economically generate electric power, the rationalization in the location of nuclear power stations is necessary, and the concrete concept of building up local community must be decided. (Kako, I.)

  20. A Novel Neutral Point Clamped Full-Bridge Topology for Transformerless Photovoltaic Grid-Connected Inverters

    Directory of Open Access Journals (Sweden)

    M. Pakdel

    2017-04-01

    Full Text Available This paper presents a novel neutral point clamped full-bridge topology for transformerless photovoltaic grid-tied inverters. Transformerless grid-connected inverters have been used widely in recent years since they offer higher efficiency and lower costs. Ground leakage current suppression is the main issue which should be considered carefully in transformerless photovoltaic grid-connected inverters. Among different methods used to decline ground leakage current, neutral point clamped (NPC topologies are considered more useful and effective. In NPC topologies, the short-circuited output voltage at the freewheeling period is clamped to the middle of the DC bus voltage. Therefore, the common-mode voltage (CM will be constant at the whole switching period. Various NPC topologies such as H6 [1], HB-ZVR [2], oH5 [3], and PN-NPC [4] have been proposed. In this paper, a novel NPC topology is proposed which has lower power losses and higher efficiency over previous topologies. Furthermore, the proposed NPC topology exhibits a similar ground leakage current with the PN-NPC topology. The proposed NPC topology is analyzed theoretically using simulation studies and an experimental prototype is provided to verify theoretical analysis and simulation studies.

  1. Ion channel electrophysiology via integrated planar patch-clamp chip with on-demand drug exchange.

    Science.gov (United States)

    Chen, Chang-Yu; Tu, Ting-Yuan; Jong, De-Shien; Wo, Andrew M

    2011-06-01

    Planar patch clamp has revolutionized characterization of ion channel behavior in drug discovery primarily via advancement in high throughput. Lab use of planar technology, however, addresses different requirements and suffers from inflexibility to enable wide range of interrogation via a single cell. This work presents integration of planar patch clamp with microfluidics, achieving multiple solution exchanges for tailor-specific measurement and allowing rapid replacement of the cell-contacting aperture. Studies via endogenously expressed ion channels in HEK 293T cells were commenced to characterize the device. Results reveal the microfluidic concentration generator produces distinct solution/drug combination/concentrations on-demand. Volume-regulated chloride channel and voltage-gated potassium channels in HEK 293T cells immersed in generated solutions under various osmolarities or drug concentrations show unique channel signature under specific condition. Excitation and blockage of ion channels in a single cell was demonstrated via serial solution exchange. Robustness of the reversible bonding and ease of glass substrate replacement were proven via repeated usage of the integrated device. The present approach reveals the capability and flexibility of integrated microfluidic planar patch-clamp system for ion channel assays. Copyright © 2011 Wiley Periodicals, Inc.

  2. Organization of the operating quality in EDF nuclear power stations

    International Nuclear Information System (INIS)

    Stolz, J.

    1976-01-01

    The organization of operating quality in EDF nuclear stations cover a number of planned and systematic actions of technical and management order carried on at station level and Nuclear Safety Department level. Priority is given to safety quality which has to remain the same during the whole life of the stations; the safety of a station depending from its designing, realization and starting up quality on one hand and from its operating methods on the other [fr

  3. A comparison between the minimal model and the glucose clamp in the assessment of insulin sensitivity across the spectrum of glucose tolerance. Insulin Resistance Atherosclerosis Study.

    Science.gov (United States)

    Saad, M F; Anderson, R L; Laws, A; Watanabe, R M; Kades, W W; Chen, Y D; Sands, R E; Pei, D; Savage, P J; Bergman, R N

    1994-09-01

    An insulin-modified frequently sampled intravenous glucose tolerance test (FSIGTT) with minimal model analysis was compared with the glucose clamp in 11 subjects with normal glucose tolerance (NGT), 20 with impaired glucose tolerance (IGT), and 24 with non-insulin-dependent diabetes mellitus (NIDDM). The insulin sensitivity index (SI) was calculated from FSIGTT using 22- and 12-sample protocols (SI(22) and SI(12), respectively). Insulin sensitivity from the clamp was expressed as SI(clamp) and SIP(clamp). Minimal model parameters were similar when calculated with SI(22) and SI(12). SI could not be distinguished from 0 in approximately 50% of diabetic patients with either protocol. SI(22) correlated significantly with SI(clamp) in the whole group (r = 0.62), and in the NGT (r = 0.53), IGT (r = 0.48), and NIDDM (r = 0.41) groups (P SIP(clamp) were expressed in the same units, SI(22) was 66 +/- 5% (mean +/- SE) and 50 +/- 8% lower than SI(clamp) and SIP(clamp), respectively. Thus, minimal model analysis of the insulin-modified FSIGTT provides estimates of insulin sensitivity that correlate significantly with those from the glucose clamp. The correlation was weaker, however, in NIDDM. The insulin-modified FSIGTT can be used as a simple test for assessment of insulin sensitivity in population studies involving nondiabetic subjects. Additional studies are needed before using this test routinely in patients with NIDDM.

  4. WVU Hydrogen Fuel Dispensing Station

    Energy Technology Data Exchange (ETDEWEB)

    Davis, William [West Virginia University Research Corporation, Morgantown, WV (United States)

    2015-09-01

    The scope of this project was changed during the course of the project. Phase I of the project was to construct a site similar to the site at Central West Virginia Regional Airport in Charleston, WV to show that duplication of the site was a feasible method of conducting hydrogen stations. Phase II of the project was necessitated due to a lack of funding that was planned for the development of the station in Morgantown. The US Department of Energy determined that the station in Charleston would be dismantled and moved to Morgantown and reassembled at the Morgantown site. This necessitated storage of the components of the station for almost a year at the NAFTC Headquarters which caused a number of issues with the equipment that will be discussed in later portions of this report. This report will consist of PHASE I and PHASE II with discussions on each of the tasks scheduled for each phase of the project.

  5. A plan for location calibration of IMS stations and near Kazakhstan

    International Nuclear Information System (INIS)

    Richards, P.G.; Kim, W.-Yo.; Khalturin, V.I.

    2001-01-01

    For purposes of monitoring compliance with the Comprehensive Nuclear Test-Ban Treaty, it is desirable to be able to locate seismic events routinely to within an uncertainty not greater than 1000 square km. From more than five years of experience with publication of the Reviewed Event Bulletin (REB) by the Prototype International Data Centre (PIDC), resulting in estimated locations for more than 100,000 seismic events, it is apparent that improved location accuracy is needed in order to reduce uncertainties below 1000 square km. In this paper, we outline a three-year program of applied research which commenced in March 2000 and which has the goal of achieving improved REB locations based upon data to be contributed to the International Data Centre from 30 IMS stations in Eastern Asia. Our first efforts will focus on the four IMS seismographic stations in Kazakhstan (AKT, BRV, KUR, MAK), together with IMS stations ZAL in Russia and AAK in Kyrgyzstan. Following the recommendations of two 'IMS Location Calibration Workshops' held in Oslo, Norway, in 1999 and 2000, our approach is to generate station-specific travel times for each observable seismic phase, as a function of distance and azimuth (and depth, where possible). Such travel times are obtained on the basis of (i) early studies based mainly on earthquake data (e.g. Nersesov and Rautian, 1964), (ii) Deep Seismic Sounding, and (iii) recent studies of nuclear and chemical explosions. We are also using (iv) an empirical approach in which phases are picked at IMS stations, for so-called Ground Truth events whose location is known quite accurately on the basis of additional data, obtained for example from local and regional networks. (author)

  6. Screening of E. coli β-clamp Inhibitors Revealed that Few Inhibit Helicobacter pylori More Effectively: Structural and Functional Characterization

    Directory of Open Access Journals (Sweden)

    Preeti Pandey

    2018-01-01

    Full Text Available The characteristic of interaction with various enzymes and processivity-promoting nature during DNA replication makes β-clamp an important drug target. Helicobacter pylori (H. pylori have several unique features in DNA replication machinery that makes it different from other microorganisms. To find out whether difference in DNA replication proteins behavior accounts for any difference in drug response when compared to E. coli, in the present study, we have tested E. coli β-clamp inhibitor molecules against H. pylori β-clamp. Various approaches were used to test the binding of inhibitors to H. pylori β-clamp including docking, surface competition assay, complex structure determination, as well as antimicrobial assay. Out of five shortlisted inhibitor molecules on the basis of docking score, three molecules, 5-chloroisatin, carprofen, and 3,4-difluorobenzamide were co-crystallized with H. pylori β-clamp and the structures show that they bind at the protein-protein interaction site as expected. In vivo studies showed only two molecules, 5-chloroisatin, and 3,4-difluorobenzamide inhibited the growth of the pylori with MIC values in micro molar range, which is better than the inhibitory effect of the same drugs on E. coli. Therefore, the evaluation of such drugs against H. pylori may explore the possibility to use to generate species-specific pharmacophore for development of new drugs against H. pylori.

  7. Screening of E. coli β-clamp Inhibitors Revealed that Few Inhibit Helicobacter pylori More Effectively: Structural and Functional Characterization.

    Science.gov (United States)

    Pandey, Preeti; Verma, Vijay; Dhar, Suman Kumar; Gourinath, Samudrala

    2018-01-11

    The characteristic of interaction with various enzymes and processivity-promoting nature during DNA replication makes β-clamp an important drug target. Helicobacter pylori ( H. pylori ) have several unique features in DNA replication machinery that makes it different from other microorganisms. To find out whether difference in DNA replication proteins behavior accounts for any difference in drug response when compared to E. coli , in the present study, we have tested E. coli β-clamp inhibitor molecules against H. pylori β-clamp. Various approaches were used to test the binding of inhibitors to H. pylori β-clamp including docking, surface competition assay, complex structure determination, as well as antimicrobial assay. Out of five shortlisted inhibitor molecules on the basis of docking score, three molecules, 5-chloroisatin, carprofen, and 3,4-difluorobenzamide were co-crystallized with H. pylori β-clamp and the structures show that they bind at the protein-protein interaction site as expected. In vivo studies showed only two molecules, 5-chloroisatin, and 3,4-difluorobenzamide inhibited the growth of the pylori with MIC values in micro molar range, which is better than the inhibitory effect of the same drugs on E. coli . Therefore, the evaluation of such drugs against H. pylori may explore the possibility to use to generate species-specific pharmacophore for development of new drugs against H. pylori .

  8. Investigating the effect of clamping force on the fatigue life of bolted plates using volumetric approach

    International Nuclear Information System (INIS)

    Esmaeili, F.; Chakherlou, T. N.; Zehsaz, M.; Hasanifard, S.

    2013-01-01

    In this paper, the effects of bolt clamping force on the fatigue life for bolted plates made from Al7075-T6 have been studied on the values of notch strength reduction factor obtained by volumetric approach. To attain stress distribution around the notch (hole) which is required for volumetric approach, nonlinear finite element simulations were carried out. To estimate the fatigue life, the available smooth S-N curve of Al7075-T6 and the notch strength reduction factor obtained from volumetric method were used. The estimated fatigue life was compared with the available experimental test results. The investigation shows that there is a good agreement between the life predicted by the volumetric approach and the experimental results for various specimens with different amount of clamping forces. Volumetric approach and experimental results showed that the fatigue life of bolted plates improves because of the compressive stresses created around the plate hole due to clamping force.

  9. Characterization of a patch-clamp microchannel array towards neuronal networks analysis

    DEFF Research Database (Denmark)

    Alberti, Massimo; Snakenborg, Detlef; Lopacinska, Joanna M.

    2010-01-01

    for simultaneous patch clamping of cultured cells or neurons in the same network. A disposable silicon/silicon dioxide (Si/SiO2) chip with a microhole array was integrated in a microfluidic system for cell handling, perfusion and electrical recording. Fluidic characterization showed that our PC mu CA can work...

  10. Negligible substrate clamping effect on piezoelectric response in (111)-epitaxial tetragonal Pb(Zr, Ti)O3 films

    International Nuclear Information System (INIS)

    Yamada, Tomoaki; Yasumoto, Jun; Ito, Daisuke; Yoshino, Masahito; Nagasaki, Takanori; Sakata, Osami; Imai, Yasuhiko; Kiguchi, Takanori; Shiraishi, Takahisa; Shimizu, Takao; Funakubo, Hiroshi

    2015-01-01

    The converse piezoelectric responses of (111)- and (001)-epitaxial tetragonal Pb(Zr 0.35 Ti 0.65 )O 3 [PZT] films were compared to investigate the orientation dependence of the substrate clamping effect. Synchrotron X-ray diffraction (XRD) and piezoelectric force microscopy revealed that the as-grown (111)-PZT film has a polydomain structure with normal twin boundaries that are changed by the poling process to inclined boundaries, as predicted by Romanov et al. [Phys. Status Solidi A 172, 225 (1999)]. Time-resolved synchrotron XRD under bias voltage showed the negligible impact of substrate clamping on the piezoelectric response in the (111)-PZT film, unlike the case for (001)-PZT film. The origin of the negligible clamping effect in the (111)-PZT film is discussed from the viewpoint of the elastic properties and the compensation of lattice distortion between neighboring domains

  11. Waste management for the Shippingport Station Decommissioning Project

    International Nuclear Information System (INIS)

    Mullee, G.R.; Schulmeister, A.R.

    1987-01-01

    The Shippingport Station Decommissioning Project (SSDP) is being performed by the US Department of Energy (DOE) with the objectives of placing the station in a radiologically safe condition, demonstrating safe and cost effective dismantlement and providing useful data for future decommissioning projects. This paper describes the development of the Waste Management Plan which is being used for the accomplishment of the SSDP. Significant aspects of the Plan are described, such as the use of a process control and inventory system. The current status of waste management activities is reported. It is concluded that SSDP has some unique aspects which will provide useful information for future decommissioning projects

  12. GIS-based locational analysis of petrol filling stations in Kaduna ...

    African Journals Online (AJOL)

    Location of environmental sensitive commercial and service activities in densely populated urban areas are guided by planning principles and standards, expressed in either structure plans or land use development plans. There has been an upsurge of filling stations within Kaduna metropolis thereby raising the questions ...

  13. Accommodating life sciences on the Space Station

    Science.gov (United States)

    Arno, Roger D.

    1987-01-01

    The NASA Ames Research Center Biological Research Project (BRP) is responsible for identifying and accommodating high priority life science activities, utilizing nonhuman specimens, on the Space Station and is charged to bridge the gap between the science community and the Space Station Program. This paper discusses the approaches taken by the BRP in accomodating these research objectives to constraints imposed by the Space Station System, while maintaining a user-friendly environment. Consideration is given to the particular research disciplines which are given priority, the science objectives in each of these disciplines, the functions and activities required by these objectives, the research equipment, and the equipment suits. Life sciences programs planned by the Space Station participating partners (USA, Europe, Japan, and Canada) are compared.

  14. Characterization of heterologously expressed transporter genes by patch- and voltage-clamp methods: Application to cyclic nucleotide-dependent responses

    KAUST Repository

    Lemtiri-Chlieh, Fouad

    2013-09-03

    The application of patch- and voltage-clamp methods to study ion transport can be limited by many hurdles: the size of the cells to be patched and/or stabbed, the subcellular localization of the molecule of interest, and its density of expression that could be too low even in their own native environment. Functional expression of genes using recombinant DNA technology not only overcomes those hurdles but also affords additional and elegant investigations such as single-point mutation studies and subunit associations/regulations. In this chapter, we give a step-by-step description of two electrophysiological methods, patch clamp and two-electrode voltage clamp (TEVC), that are routinely used in combination with heterologous gene expression to assist researchers interested in the identification and characterization of ion transporters. We describe how to (1) obtain and maintain the cells suitable for the use with each of the above-mentioned methods (i.e., HEK-293 cells and yeast spheroplasts to use with the patch-clamp methodology and Xenopus laevis oocytes with TEVC), (2) transfect/inject them with the gene of interest, and (3) record ion transport activities. © Springer Science+Business Media New York 2013.

  15. Characterization of heterologously expressed transporter genes by patch- and voltage-clamp methods: Application to cyclic nucleotide-dependent responses

    KAUST Repository

    Lemtiri-Chlieh, Fouad; Ali, Rashid Ayesha

    2013-01-01

    The application of patch- and voltage-clamp methods to study ion transport can be limited by many hurdles: the size of the cells to be patched and/or stabbed, the subcellular localization of the molecule of interest, and its density of expression that could be too low even in their own native environment. Functional expression of genes using recombinant DNA technology not only overcomes those hurdles but also affords additional and elegant investigations such as single-point mutation studies and subunit associations/regulations. In this chapter, we give a step-by-step description of two electrophysiological methods, patch clamp and two-electrode voltage clamp (TEVC), that are routinely used in combination with heterologous gene expression to assist researchers interested in the identification and characterization of ion transporters. We describe how to (1) obtain and maintain the cells suitable for the use with each of the above-mentioned methods (i.e., HEK-293 cells and yeast spheroplasts to use with the patch-clamp methodology and Xenopus laevis oocytes with TEVC), (2) transfect/inject them with the gene of interest, and (3) record ion transport activities. © Springer Science+Business Media New York 2013.

  16. Emergency protection and nuclear power station remote monitoring

    International Nuclear Information System (INIS)

    Nowak, K.; Wolf, H.

    1986-01-01

    The States of the Federal Republic of Germany are planning emergency protection measures for the environment of nuclear power stations based on their statutory duty of care. In this connection the paper explains to what extent remote monitoring of nuclear power stations practised by the Federal Supervisory Authorities may support the design and implementation of emergency protection measures. (orig.) [de

  17. Gain-clamping techniques in two-stage double-pass L-band EDFA

    Indian Academy of Sciences (India)

    Two designs of long-wavelength band erbium-doped fiber amplifier (L-band. EDFA) for gain clamping in double-pass systems are demonstrated and compared. The first design is based on ring laser technique where a backward amplified spontaneous emis- sion (ASE) from the second stage is routed into the feedback loop ...

  18. Analysis of the Pallet Clamping Conditions in Work Positioning

    OpenAIRE

    L. A. Kolesnikov

    2016-01-01

    Pallets of automatic transfer lines serve as the technological and work-transfer equipment. However, their design is based on the general principles of designing machine accessories. Calculation of the basic design parameters of work based on their functioning features is fairly relevant.In pallet transfer movement over work positioning there is a mismatch between axes of the basic bushing of a pallet and the clamping locks of positioning. The paper identifies the factors influencing it, and ...

  19. The Piezo Actuator-Driven Pulsed Water Jet System for Minimizing Renal Damage after Off-Clamp Laparoscopic Partial Nephrectomy.

    Science.gov (United States)

    Kamiyama, Yoshihiro; Yamashita, Shinichi; Nakagawa, Atsuhiro; Fujii, Shinji; Mitsuzuka, Koji; Kaiho, Yasuhiro; Ito, Akihiro; Abe, Takaaki; Tominaga, Teiji; Arai, Yoichi

    2017-09-01

    In the setting of partial nephrectomy (PN) for renal cell carcinoma, postoperative renal dysfunction might be caused by surgical procedure. The aim of this study was to clarify the technical safety and renal damage after off-clamp laparoscopic PN (LPN) with a piezo actuator-driven pulsed water jet (ADPJ) system. Eight swine underwent off-clamp LPN with this surgical device, while off-clamp open PN was also performed with radio knife or soft coagulation. The length of the removed kidney was 40 mm, and the renal parenchyma was dissected until the renal calyx became clearly visible. The degree of renal degeneration from the resection surface was compared by Hematoxylin-Eosin staining and immunostaining for 1-methyladenosine, a sensitive marker for the ischemic tissue damage. The mRNA levels of neutrophil gelatinase-associated lipocalin (Ngal), a biomarker for acute kidney injury, were measured by quantitative real-time PCR. Off-clamp LPN with ADPJ system was successfully performed while preserving fine blood vessels and the renal calix with little bleeding. In contrast to other devices, the resection surface obtained with the ADPJ system showed only marginal degree of ischemic changes. Indeed, the expression level of Ngal mRNA was lower in the resection surface obtained with the ADPJ system than that with soft coagulation (p = 0.02). Furthermore, using the excised specimens of renal cell carcinoma, we measured the breaking strength at each site of the human kidney, suggesting the applicability of this ADPJ to clinical trials. In conclusion, off-clamp LPN with the ADPJ system could be safely performed with attenuated renal damage.

  20. Space Station personal hygiene study

    Science.gov (United States)

    Prejean, Stephen E.; Booher, Cletis R.

    1986-01-01

    A personal hygiene system is currently under development for Space Station application that will provide capabilities equivalent to those found on earth. This paper addresses the study approach for specifying both primary and contingency personal hygiene systems and provisions for specified growth. Topics covered are system definition and subsystem descriptions. Subsystem interfaces are explored to determine which concurrent NASA study efforts must be monitored during future design phases to stay up-to-date on critical Space Station parameters. A design concept for a three (3) compartment personal hygiene facility is included as a baseline for planned test and verification activities.

  1. 2D and 3D assessment of sustentaculum tali screw fixation with or without Screw Targeting Clamp.

    Science.gov (United States)

    De Boer, A Siebe; Van Lieshout, Esther M M; Vellekoop, Leonie; Knops, Simon P; Kleinrensink, Gert-Jan; Verhofstad, Michael H J

    2017-12-01

    Precise placement of sustentaculum tali screw(s) is essential for restoring anatomy and biomechanical stability of the calcaneus. This can be challenging due to the small target area and presence of neurovascular structures on the medial side. The aim was to evaluate the precision of positioning of the subchondral posterior facet screw and processus anterior calcanei screw with or without a Screw Targeting Clamp. The secondary aim was to evaluate the added value of peroperative 3D imaging over 2D radiographs alone. Twenty Anubifix™ embalmed, human anatomic lower limb specimens were used. A subchondral posterior facet screw and a processus anterior calcanei screw were placed using an extended lateral approach. A senior orthopedic trauma surgeon experienced in calcaneal fracture surgery and a senior resident with limited experience in calcaneal surgery performed screw fixation in five specimens with and in five specimens without the clamp. 2D lateral and axial radiographs and a 3D recording were obtained postoperatively. Anatomical dissection was performed postoperatively as a diagnostic golden standard in order to obtain the factual screw positions. Blinded assessment of quality of fixation was performed by two surgeons. In 2D, eight screws were considered malpositioned when placed with the targeting device versus nine placed freehand. In 3D recordings, two additional screws were malpositioned in each group as compared to the golden standard. As opposed to the senior surgeon, the senior resident seemed to get the best results using the Screw Targeting Clamp (number of malpositioned screws using freehand was eight, and using the targeting clamp five). In nine out of 20 specimens 3D images provided additional information concerning target area and intra-articular placement. Based on the 3D assessment, five additional screws would have required repositioning. Except for one, all screw positions were rated equally after dissection when compared with 3D examinations

  2. Flight Planning Branch NASA Co-op Tour

    Science.gov (United States)

    Marr, Aja M.

    2013-01-01

    This semester I worked with the Flight Planning Branch at the NASA Johnson Space Center. I learned about the different aspects of flight planning for the International Space Station as well as the software that is used internally and ISSLive! which is used to help educate the public on the space program. I had the opportunity to do on the job training in the Mission Control Center with the planning team. I transferred old timeline records from the planning team's old software to the new software in order to preserve the data for the future when the software is retired. I learned about the operations of the International Space Station, the importance of good communication between the different parts of the planning team, and enrolled in professional development classes as well as technical classes to learn about the space station.

  3. Investigating ion channel conformational changes using voltage clamp fluorometry.

    Science.gov (United States)

    Talwar, Sahil; Lynch, Joseph W

    2015-11-01

    Ion channels are membrane proteins whose functions are governed by conformational changes. The widespread distribution of ion channels, coupled with their involvement in most physiological and pathological processes and their importance as therapeutic targets, renders the elucidation of these conformational mechanisms highly compelling from a drug discovery perspective. Thanks to recent advances in structural biology techniques, we now have high-resolution static molecular structures for members of the major ion channel families. However, major questions remain to be resolved about the conformational states that ion channels adopt during activation, drug modulation and desensitization. Patch-clamp electrophysiology has long been used to define ion channel conformational states based on functional criteria. It achieves this by monitoring conformational changes at the channel gate and cannot detect conformational changes occurring in regions distant from the gate. Voltage clamp fluorometry involves labelling cysteines introduced into domains of interest with environmentally sensitive fluorophores and inferring structural rearrangements from voltage or ligand-induced fluorescence changes. Ion channel currents are monitored simultaneously to verify the conformational status. By defining real time conformational changes in domains distant from the gate, this technique provides unexpected new insights into ion channel structure and function. This review aims to summarise the methodology and highlight recent innovative applications of this powerful technique. This article is part of the Special Issue entitled 'Fluorescent Tools in Neuropharmacology'. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. A Study of Public Radio Stations' Educational Services, 1978-79.

    Science.gov (United States)

    Corporation for Public Broadcasting, Washington, DC.

    This second national survey of public radio stations' involvement in educational services to schools, colleges, and universities was conducted by the Corporation for Public Broadcasting (CPB) for use by individual public radio stations, educational agencies, and other organizations interested and involved in planning public radio's services to…

  5. 40 CFR 52.2035 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... Stations (PAMS) Program. 52.2035 Section 52.2035 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Pennsylvania § 52.2035 Photochemical Assessment Monitoring Stations (PAMS) Program. On September 23, 1994... (PAMS) Program as a state implementation plan (SIP) revision, as required by section 182(c)(1) of the...

  6. Voltage clamp methods for the study of membrane currents and SR Ca2+ release in adult skeletal muscle fibres

    Science.gov (United States)

    Hernández-Ochoa, Erick O.; Schneider, Martin F.

    2012-01-01

    Skeletal muscle excitation-contraction (E-C)1 coupling is a process composed of multiple sequential stages, by which an action potential triggers sarcoplasmic reticulum (SR)2 Ca2+ release and subsequent contractile activation. The various steps in the E-C coupling process in skeletal muscle can be studied using different techniques. The simultaneous recordings of sarcolemmal electrical signals and the accompanying elevation in myoplasmic Ca2+, due to depolarization-initiated SR Ca2+ release in skeletal muscle fibres, have been useful to obtain a better understanding of muscle function. In studying the origin and mechanism of voltage dependency of E-C coupling a variety of different techniques have been used to control the voltage in adult skeletal fibres. Pioneering work in muscles isolated from amphibians or crustaceans used microelectrodes or ‘high resistance gap’ techniques to manipulate the voltage in the muscle fibres. The development of the patch clamp technique and its variant, the whole-cell clamp configuration that facilitates the manipulation of the intracellular environment, allowed the use of the voltage clamp techniques in different cell types, including skeletal muscle fibres. The aim of this article is to present an historical perspective of the voltage clamp methods used to study skeletal muscle E-C coupling as well as to describe the current status of using the whole-cell patch clamp technique in studies in which the electrical and Ca2+ signalling properties of mouse skeletal muscle membranes are being investigated. PMID:22306655

  7. Strategy for success in maintenance management at Point Lepreau nuclear generating station

    International Nuclear Information System (INIS)

    White, R.M.

    1987-01-01

    Improvements in availability of the station and in productivity of workers were achieved at Point Lepreau Nuclear Generating Station through implementation of a Maintenance Management System, which incorporates work planning and outage management techniques. Eight software systems on a VAX 11/70 minicomputer control work orders, temporary and permanent design changes, parts and material inventories, time keeping, and project management. All maintenance is coordinated through a regular planning meeting

  8. Trends in the capital costs of CANDU generating stations

    International Nuclear Information System (INIS)

    Yu, A.M.

    1982-09-01

    This paper consolidates the actual cost experience gained by Atomic Energy of Canada Limited, Ontario Hydro, and other Canadian electric utlities in the planning, design and construction of CANDU-PHWR (CANada Deuterium Uranium-Pressurized Heavy Water Reactor) generating stations over the past 30 years. For each of the major CANDU-PHWR generating stations in operation and under construction in Canada, an analysis is made to trace the evolution of the capital cost estimates. Major technical, economic and other parameters that affect the cost trends of CANDU-PHWR generating stations are identified and their impacts assessed. An analysis of the real cost of CANDU generating stations is made by eliminating interest during construction and escalation, and the effects of planned deferment of in-service dates. An historical trend in the increase in the real cost of CANDU power plants is established. Based on the cost experience gained in the design and construction of CANDU-PHWR units in Canada, as well as on the assessment of parameters that influence the costs of such projects, the future costs of CANDU-PHWRs are presented

  9. The planning of decommissioning activities within nuclear facilities - Generating a Baseline Decommissioning Plan

    International Nuclear Information System (INIS)

    Meek, N.C.; Ingram, S.; Page, J.

    2003-01-01

    BNFL Environmental Services has developed planning tools to meet the emerging need for nuclear liabilities management and decommissioning engineering both in the UK and globally. It can provide a comprehensive baseline planning service primarily aimed at nuclear power stations and nuclear plant. The paper develops the following issues: Decommissioning planning; The baseline decommissioning plan;The process; Work package; Compiling the information; Deliverables summary; Customer Benefits; - Planning tool for nuclear liability life-cycle management; - Robust and reliable plans based upon 'real' experience; - Advanced financial planning; - Ascertaining risk; - Strategy and business planning. The following Deliverables are mentioned:1. Site Work Breakdown Structure; 2. Development of site implementation strategy from the high level decommissioning strategy; 3. An end point definition for the site; 4. Buildings, operational systems and plant surveys; 5. A schedule of condition for the site; 6. Development of technical approach for decommissioning for each work package; 7. Cost estimate to WBS level 5 for each work package; 8. Estimate of decommissioning waste arisings for each work package; 9. Preparation of complete decommissioning programme in planning software to suit client; 10. Risk modelling of work package and overall project levels; 11. Roll up of costs into an overall cost model; 12. Cash flow, waste profiling and resource profiling against the decommissioning programme; 13. Preparation and issue of Final Report. Finally The BDP process is represented by a flowchart listing the following stages: [Power Station project assigned] → [Review project and conduct Characterisation review of power station] → [Identify work packages] → [Set up WBS to level 3] → [Assign work packages] → [Update WBS to level 4] →[Develop cost model] → [Develop logic network] → [Develop risk management procedure] ] → [Develop project strategy document]→ [Work package

  10. Linking the space shuttle and space stations early docking technologies from concept to implementation

    CERN Document Server

    Shayler, David J

    2017-01-01

    How could the newly authorized space shuttle help in the U.S. quest to build a large research station in Earth orbit? As a means of transporting goods, the shuttle could help supply the parts to the station. But how would the two entitles be physically linked? Docking technologies had to constantly evolve as the designs of the early space stations changed. It was hoped the shuttle would make missions to the Russian Salyut and American Skylab stations, but these were postponed until the Mir station became available, while plans for getting a new U. S. space station underway were stalled. In Linking the Space Shuttle and Space Stations, the author delves into the rich history of the Space Shuttle and its connection to these early space stations, culminating in the nine missions to dock the shuttle to Mir. By 1998, after nearly three decades of planning and operations, shuttle missions to Mir had resulted in: • A proven system to link up the space shuttle to a space station • Equipment and hands-on experienc...

  11. From city’s station to station city. An integrative spatial approach to the (redevelopment of station areas

    Directory of Open Access Journals (Sweden)

    Ana Luísa Martins da Conceição

    2014-12-01

    Full Text Available Since its origin, the railway station has had a complicated relationship with the city, demanding periodical updates, particularly regarding spatial issues. With the aim of improving the liveability of station areas, current redevelopment projects are reconceptualising them as balanced transport ‘nodes’ and ‘places’ in the city. However, the proposed spatial solutions do not fully support the sought after economic, social and environmental performances. These intentions continue to be predominantly bounded with the (abstract planological level, not finding appropriate translation at the (concrete spatial design level. Further, the interdisciplinary nature of the highly complex planning and design processes of station areas, which should contribute to enhance the performance of their spaces, reinforces constraints and relegates architecture to a marginal role in this quest. It is thus necessary to understand how architecture can contribute to the improvement of the spatial performance of contemporary stations areas, supporting their current reconceptualization. To gain this understanding, the research explored the factors which influence the spatial definition and performance of European High Speed Train station areas, using “design research” and “research by design”. Via a theoretical integrative framework, synthesized from knowledge developed by architecture and other sciences, case studies of ‘through’ stations were analysed and compared. Six cases, encapsulating the most recurrent relative positions of the railway (infrastructure and the station building towards the(ir direct built environment, were chosen out of a large sample. For each category (cases with railway tracks at (a ground level, (b elevated level and (c underground level, two cases, featuring an adapted station building and a newly built one, were studied. Their physical and functional characteristics were mapped at several scales and moments (in history, as

  12. del Nido versus St. Thomas Cardioplegia Solutions: A Single-Center Retrospective Analysis of Post Cross-Clamp Defibrillation Rates.

    Science.gov (United States)

    Buel, Shane T; Striker, Carrie Whittaker; O'Brien, James E

    2016-06-01

    There are many cardioplegia solutions currently in use for pediatric cardiopulmonary bypass (CPB). The most common being del Nido solution. Another common cardioplegia solution used for pediatric CPB is St. Thomas. In October 2014, Children's Mercy Kansas City changed from the use of modified St. Thomas to del Nido. This study compared rates of post cross-clamp fibrillation requiring defibrillation between del Nido solution and modified St. Thomas solution stratified by weight at Children's Mercy Kansas City. This retrospective study consisted of 394 patients who underwent cardiac surgery requiring cardioplegia between January 1, 2014 and July 31, 2015. The outcome measured was defibrillation upon cross-clamp removal. Statistical significance was determined using Fishers exact test with a two-sided significance level of .05. Incidence of defibrillation post cross-clamp removal was 4.4% in the del Nido group and 26.8% in the St. Thomas group (p Thomas group (p Thomas group (p Thomas group (p 60-kg category had an incidence of defibrillation of 16.7% in the del Nido group and 63% in the St. Thomas group (p Thomas and del Nido cardioplegia solutions. Analyses of weight stratifications demonstrate a decrease in the rate of defibrillation post cross-clamp removal in all categories within the del Nido group.

  13. Riel Converter Station, Winnipeg: Site selection and environmental assessment status report

    International Nuclear Information System (INIS)

    1991-01-01

    As part of its expansion plans, Manitoba Hydro is planning to construct a converter station east of Winnipeg to receive power from a 850-km dc transmission line which will be constructed to bring power from a new generating station in the north of the province. Work performed to date on site selection and preliminary environmental assessment of the converter station is reviewed. The role of the converter station is described and the potential impacts are summarized in such areas as employment opportunities, pollution and noise during construction, electric and magnetic field effects, and land use impacts. Site selection criteria are outlined and potential sites are identified and evaluated. The Deacon site has been chosen as the preferred site since it has a number of inherent advantages including existing ownership by Manitoba Hydro, proximity to existing transmission rights-of-way, and low visual and land-use impact. 12 figs

  14. Equipment concept design and development plans for microgravity science and applications research on space station: Combustion tunnel, laser diagnostic system, advanced modular furnace, integrated electronics laboratory

    Science.gov (United States)

    Uhran, M. L.; Youngblood, W. W.; Georgekutty, T.; Fiske, M. R.; Wear, W. O.

    1986-01-01

    Taking advantage of the microgravity environment of space NASA has initiated the preliminary design of a permanently manned space station that will support technological advances in process science and stimulate the development of new and improved materials having applications across the commercial spectrum. Previous studies have been performed to define from the researcher's perspective, the requirements for laboratory equipment to accommodate microgravity experiments on the space station. Functional requirements for the identified experimental apparatus and support equipment were determined. From these hardware requirements, several items were selected for concept designs and subsequent formulation of development plans. This report documents the concept designs and development plans for two items of experiment apparatus - the Combustion Tunnel and the Advanced Modular Furnace, and two items of support equipment the Laser Diagnostic System and the Integrated Electronics Laboratory. For each concept design, key technology developments were identified that are required to enable or enhance the development of the respective hardware.

  15. Acute phase response in lactating dairy cows during hyperinsulinemic hypoglycaemic and hyperinsulinemic euglycaemic clamps and after intramammary LPS challenge.

    Science.gov (United States)

    De Matteis, L; Bertoni, G; Lombardelli, R; Wellnitz, O; Van Dorland, H A; Vernay, M C M B; Bruckmaier, R M; Trevisi, E

    2017-06-01

    The link between energy availability, turnover of energy substrates and the onset of inflammation in dairy cows is complex and poorly investigated. To clarify this, plasma inflammatory variables were measured in mid-lactating dairy cows allocated to three groups: hyperinsulinemic hypoglycaemic clamp, induced by insulin infusion (HypoG, n = 5); hyperinsulinemic euglycaemic clamp, induced by insulin and glucose infusion (EuG; n = 6); control, receiving a saline solution infusion (NaCl; n = 6). At 48 h after the start of i.v. infusions, two udder quarters per cow were challenged with 200 μg of E. coli lipopolysaccharide (LPS). Individual blood samples were taken before clamps, before LPS challenge (i.e. 48 h after clamps) and 6.5 h after. At 48 h, positive acute phase proteins (posAPP) did not differ among groups, whereas albumin and cholesterol (index of lipoproteins), negative APP (negAPP), were lower (p insulin at the tissue-level makes dairy cows more susceptible to inflammatory events. In contrast, HypoG seems to attenuate the inflammatory response. Journal of Animal Physiology and Animal Nutrition © 2016 Blackwell Verlag GmbH.

  16. Sizewell 'B' power station public inquiry: CEGB proof of evidence

    International Nuclear Information System (INIS)

    Henderson, B.

    1982-11-01

    Architectural concepts and design proposals associated with the proposed Sizewell B power station are outlined. The figures are in a separate volume. They consist of the site layout plan, an axonometric drawing of the site, an elevations drawing and a colour perspective drawing of 'A', 'B' and 'C' stations. (U.K.)

  17. Impact of delayed umbilical cord clamping on public cord blood donations: can we help future patients and benefit infant donors?

    Science.gov (United States)

    Ciubotariu, Rodica; Scaradavou, Andromachi; Ciubotariu, Ilinca; Tarnawski, Michal; Lloyd, Sara; Albano, Maria; Dobrila, Ludy; Rubinstein, Pablo; Grunebaum, Amos

    2018-03-25

    Cord blood (CB) is a widely accepted stem cell source and its clinical utilization depends, to a great extent, on its cell content. Birth-to-clamping (BTC) time of umbilical cord determines placental transfusion to the newborn, and the remaining blood that can be collected and banked. The 2017 Committee Opinion of the American College of Obstetrics and Gynecologists (ACOG) recommends a delay of "at least 30-60 seconds" before clamping the cord for all newborns to ensure adequate iron stores. The impact of delayed cord clamping (DCC) on public CB banking can be substantial. Cord blood units (CBUs) collected from 1210 mothers at one hospital were evaluated for total nucleated cells (TNCs) and weight/volume based on time to clamping. Bank staff recorded BTC time in seconds as reported by obstetricians; collections were performed ex utero. Immediate clamping was defined as BTC of less than 30 seconds, whereas DCC was defined as BTC of 30 seconds or more. Cord clamping was immediate in 903 (75%) and delayed in 307 (25%) deliveries. Successful recovery (% clinical CBUs) decreased 10-fold with DCC of more than 60 seconds (22% vs. 2.4%, p < 0.001). CBUs collected after DCC of more than 60 seconds had significantly lower TNC counts than those after DCC of less than 60 seconds (p < 0.0001). Furthermore, 38% to 46% of CBUs after DCC of more than 60 seconds had volume of less than 40 mL. Our study indicates that DCC of 30 to 60 seconds has a small negative impact on collection of high-TNC-count CBUs. However, increasing BTC to more than 60 seconds decreases significantly both TNC content and volume, reducing drastically the chances of obtaining clinically useful CBUs. © 2018 AABB.

  18. Correlation of open cell-attached and excised patch clamp techniques.

    Science.gov (United States)

    Filipovic, D; Hayslett, J P

    1995-11-01

    The excised patch clamp configuration provides a unique technique for some types of single channel analyses, but maintenance of stable, long-lasting preparations may be confounded by rundown and/or rapid loss of seal. Studies were performed on the amiloride-sensitive Na+ channel, located on the apical surface of A6 cells, to determine whether the nystatin-induced open cell-attached patch could serve as an alternative configuration. Compared to excised inside-out patches, stable preparations were achieved more readily with the open cell-attached patch (9% vs. 56% of attempts). In both preparations, the current voltage (I-V) relation was linear, current amplitudes were equal at opposite equivalent clamped voltages, and Erev was zero in symmetrical Na+ solutions, indicating similar Na+ activities on the cytosolic and external surfaces of the patch. Moreover, there was no evidence that nystatin altered channel activity in the patch because slope conductance (3-4pS) and Erev (75 mV), when the bath was perfused with a high K:low Na solution (ENa = 80 mV), were nearly equal in both patch configurations. Our results therefore indicate that the nystatin-induced open cell-attached patch can serve as an alternative approach to the excised inside-out patch when experiments require modulation of univalent ions in the cytosol.

  19. Present status and future of the sophisticated work station

    Science.gov (United States)

    Ishida, Haruhisa

    The excellency of the work station is explained, by comparing the functions of software and hardware of work station with those of personal computer. As one of the examples utilizing the functions of work station, desk top publishing is explained. By describing the competition between the Group of ATT · Sun Microsystems which intends to have the leadership by integrating Berkeley version which is most popular at this moment and System V version, and the group led by IBM, future of UNIX as OS of work station is predicted. Development of RISC processor, TRON Plan and Sigma Projects by MITI are also mentioned as its background.

  20. Solution Methods for the Periodic Petrol Station Replenishment Problem

    Directory of Open Access Journals (Sweden)

    C Triki

    2013-12-01

    Full Text Available In this paper we introduce the Periodic Petrol Station Replenishment Problem (PPSRP over a T-day planning horizon and describe four heuristic methods for its solution. Even though all the proposed heuristics belong to the common partitioning-then-routing paradigm, they differ in assigning the stations to each day of the horizon. The resulting daily routing problems are then solved exactly until achieving optimalization. Moreover, an improvement procedure is also developed with the aim of ensuring a better quality solution. Our heuristics are tested and compared in two real-life cases, and our computational results show encouraging improvements with respect to a human planning solution

  1. How Do Lessons Learned on the International Space Station (ISS) Help Plan Life Support for Mars?

    Science.gov (United States)

    Jones, Harry W.; Hodgson, Edward W.; Gentry, Gregory J.; Kliss, Mark H.

    2016-01-01

    How can our experience in developing and operating the International Space Station (ISS) guide the design, development, and operation of life support for the journey to Mars? The Mars deep space Environmental Control and Life Support System (ECLSS) must incorporate the knowledge and experience gained in developing ECLSS for low Earth orbit, but it must also meet the challenging new requirements of operation in deep space where there is no possibility of emergency resupply or quick crew return. The understanding gained by developing ISS flight hardware and successfully supporting a crew in orbit for many years is uniquely instructive. Different requirements for Mars life support suggest that different decisions may be made in design, testing, and operations planning, but the lessons learned developing the ECLSS for ISS provide valuable guidance.

  2. Development of the clamp-on ultrasound flow meter for steam in pipe

    International Nuclear Information System (INIS)

    Kawaguchi, Tatsuya; Tsukada, Keisuke; Kikura, Hiroshige; Tanaka, Katsuhiko; Umezawa, Shuichi

    2014-01-01

    Gas flow metering of a pipe flow such as chemical plant, reactors and power stations is one of the significant techniques that enable to diagnose and control the behavior of working fluid, and to govern the entire fluid system in the industrial facilities. In order to operate the aforementioned systems, the precise measurement of the flow rate is required. The conventional flow meter, however, needs the installation of the spool piece that disturbs the stable and continuous operation of the plants. i.e., the destructive set-up process of the measurement section is necessary. In this study, the novel ultrasound gas flow metering technique has been developed by means of the clamp-on ultrasound transmitter and receivers. By the numerical simulation, the ultrasound propagation through the gas and metal pipe was firstly investigated. The effects of the external damping material, applicable vapor pressure range as well as the appropriate shape of the acoustic lens were analyzed that was followed by the feasibility test of the actual measurement system. The pressurized vapor flow was used as a working fluid. Pressure and sensor dimension were varied to compare the efficiency of the ultrasound transmission between transducers. The temperature of the working fluid was beyond 373 K. The ultrasound pulsar-receiver was used that could control the frequency, amplitude and phase of the burst sinusoids. The signal processing algorithm was developed in order to discriminate the direct signal through the gaseous flow from the unwanted circumference noise through the solid stainless pipe. The linear relation between flow rate and ultrasound peak shift was confirmed. (author)

  3. Future plans for the design and construction of fast reactor power stations in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Kempken, M.; Koehler, M.; Wolff, M.

    1978-01-01

    Some important design features of future fast reactors in the Federal Republic of Germany (FRG) are presented, in particular for the demonstration plant SNR 2 which is to follow the prototype SNR 300, presently under construction in Kalkar. The SNR 2 conceptual design will be based on the SNR 300 design as far as possible. Programmes for the introduction of fast breeder reactor power stations on the part of the governments, the utilities and suppliers are based on broad international co-operation. The FRG is a country which imports a high proportion of its primary energy and it has rather small resources of natural uranium. The natural uranium realistically available to the FRG will allow nuclear energy to play a substantial role in the long-term energy supply only if present uranium utilization based on LWRs is supplemented and replaced by breeder reactor utilization later. To maintain this option, efforts towards the development, design and construction of fast breeder reactors have to be intensively continued in the FRG. The construction of the first large power station with a fast breeder reactor, SNR 2, will, according to present planning, start in the middle of the 80s. Operation can be expected to start at the beginning of the 90s. The present fast breeder programme in the FRG promises to develop reactors, reprocessing and fuel manufacturing plants to such a degree that by the end of this century the introduction of a substantial number of fast reactor power stations will be possible. (author)

  4. Negligible substrate clamping effect on piezoelectric response in (111)-epitaxial tetragonal Pb(Zr, Ti)O{sub 3} films

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Tomoaki, E-mail: t-yamada@nucl.nagoya-u.ac.jp [Department of Materials, Physics and Energy Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); PRESTO, Japan Science and Technology Agency, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012 (Japan); Yasumoto, Jun; Ito, Daisuke; Yoshino, Masahito; Nagasaki, Takanori [Department of Materials, Physics and Energy Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Sakata, Osami [Synchrotron X-ray Station at SPring-8 and Synchrotron X-ray Group, National Institute for Materials Science, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Department of Innovative and Engineered Material, Tokyo Institute of Technology, Yokohama 226-8503 (Japan); Imai, Yasuhiko [Japan Synchrotron Radiation Research Institute, SPring-8, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Kiguchi, Takanori [Institute for Materials Research, Tohoku University, Sendai, Miyagi 980-8577 (Japan); Shiraishi, Takahisa; Shimizu, Takao; Funakubo, Hiroshi [Department of Innovative and Engineered Material, Tokyo Institute of Technology, Yokohama 226-8503 (Japan)

    2015-08-21

    The converse piezoelectric responses of (111)- and (001)-epitaxial tetragonal Pb(Zr{sub 0.35}Ti{sub 0.65})O{sub 3} [PZT] films were compared to investigate the orientation dependence of the substrate clamping effect. Synchrotron X-ray diffraction (XRD) and piezoelectric force microscopy revealed that the as-grown (111)-PZT film has a polydomain structure with normal twin boundaries that are changed by the poling process to inclined boundaries, as predicted by Romanov et al. [Phys. Status Solidi A 172, 225 (1999)]. Time-resolved synchrotron XRD under bias voltage showed the negligible impact of substrate clamping on the piezoelectric response in the (111)-PZT film, unlike the case for (001)-PZT film. The origin of the negligible clamping effect in the (111)-PZT film is discussed from the viewpoint of the elastic properties and the compensation of lattice distortion between neighboring domains.

  5. Quantitative analysis of dual whole-cell voltage-clamp determination of gap junctional conductance

    NARCIS (Netherlands)

    van Rijen, H. V.; Wilders, R.; van Ginneken, A. C.; Jongsma, H. J.

    1998-01-01

    The dual whole-cell voltage-clamp technique is used widely for determination of kinetics and conductance of gap junctions. The use of this technique may, however, occasion to considerable errors. We have analysed the errors in steady state junctional conductance measurements under different

  6. Fifteen-foot diameter modular space station Kennedy Space Center launch site support definition (space station program Phase B extension definition)

    Science.gov (United States)

    Bjorn, L. C.; Martin, M. L.; Murphy, C. W.; Niebla, J. F., V

    1971-01-01

    This document defines the facilities, equipment, and operational plans required to support the MSS Program at KSC. Included is an analysis of KSC operations, a definition of flow plans, facility utilization and modifications, test plans and concepts, activation, and tradeoff studies. Existing GSE and facilities that have a potential utilization are identified, and new items are defined where possible. The study concludes that the existing facilities are suitable for use in the space station program without major modification from the Saturn-Apollo configuration.

  7. J-integral analysis of heterogeneous mismatched girth welds in clamped single-edge notched tension specimens

    International Nuclear Information System (INIS)

    Hertelé, Stijn; De Waele, Wim; Verstraete, Matthias; Denys, Rudi; O'Dowd, Noel

    2014-01-01

    Flaw assessment procedures require a quantification of crack driving force, and such procedures are generally based on the assumption of weld homogeneity. However, welds generally have a heterogeneous microstructure, which will influence the crack driving force. This paper describes a stress-based methodology to assess complex heterogeneous welds using a J-based approach. Clamped single-edge notched tension specimens, representative of girth weld flaws, are analyzed and the influence of weld heterogeneity on crack driving force has been determined. The use of a modified limit load for heterogeneous welds is proposed, suitable for implementation in a ‘homogenized’ J-integral estimation scheme. It follows from an explicit modification of an existing solution for centre cracked tension specimens. The proposed solution provides a good estimate of crack driving force and any errors in the approximation may be accounted for by means of a small safety factor on load bearing capacity. - Highlights: • We present a crack driving force estimation procedure for heterogeneous welds. • The procedure is based on a ‘homogenized’ version of the EPRI equation. • Complex welds are translated into equivalent idealized mismatched welds. • The procedure is validated for clamped SE(T) specimens. • A mismatch limit load for clamped SE(T) specimens is developed

  8. Real-Time Track Reallocation for Emergency Incidents at Large Railway Stations

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2015-01-01

    Full Text Available After track capacity breakdowns at a railway station, train dispatchers need to generate appropriate track reallocation plans to recover the impacted train schedule and minimize the expected total train delay time under stochastic scenarios. This paper focuses on the real-time track reallocation problem when tracks break down at large railway stations. To represent these cases, virtual trains are introduced and activated to occupy the accident tracks. A mathematical programming model is developed, which aims at minimizing the total occupation time of station bottleneck sections to avoid train delays. In addition, a hybrid algorithm between the genetic algorithm and the simulated annealing algorithm is designed. The case study from the Baoji railway station in China verifies the efficiency of the proposed model and the algorithm. Numerical results indicate that, during a daily and shift transport plan from 8:00 to 8:30, if five tracks break down simultaneously, this will disturb train schedules (result in train arrival and departure delays.

  9. Report on Darlington nuclear generating station

    International Nuclear Information System (INIS)

    1985-12-01

    The Select Committee on Energy was appointed on July 10, 1985 by the Legislative Assembly of the Province of Ontario in order to inquire into and report on Ontario Hydro affairs within ten months. Two sessions were planned the first of which was a review of the Darlington Nuclear Generating Station. Darlington is a large, 4 unit nuclear-powered electricity generating station currently under construction on the shore of Lake Ontario in the town of Newcastle. At the time the Committee met, construction had been underway for over four years. The first two units are scheduled to become operational in 1988 and 1989 with the second two scheduled to become operational in 1991 and 1992. The total estimated cost of the station is $10.895 billion of which $3.66 billion has been spent and $3.385 billion has been committed. Though the nuclear industry has been a major area of investment in Ontario over the past decade, the demand for electrical power from nuclear stations has been significantly decreased. This report focusses on the need for Darlington and public policy issues involved in planning and completing it. The Committee proposed the following recommendations: 1) The relationship between the Government of Ontario and Ontario Hydro and their individual responsibilities should be clarified. 2) An independent review of the Ontario Hydro demand/supply options should be carried out. 3) No further significant contracts for Darlington units 3 and 4 should be let for materials not required for construction during the next 6 months while the Committee studies demand and supply options

  10. Five-Level Z-Source Neutral Point-Clamped Inverter

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Blaabjerg, Frede

    2007-01-01

    This paper proposes a five-level Z-source neutralpoint- clamped (NPC) inverter with two Z-source networks functioning as intermediate energy storages coupled between dc sources and NPC inverter circuitry. Analyzing the operational principles of Z-source network with partial dclink shoot......-through scheme reveals the hidden theories in the five-level Z-source NPC inverter unlike the operational principle appeared in the general two-level Z-source inverter, so that the five-level Z-source NPC inverter can be designed with the modulation of carrier-based phase disposition (PD) or alternative phase...

  11. Integrated planning of electric vehicles routing and charging stations location considering transportation networks and power distribution systems

    Directory of Open Access Journals (Sweden)

    Andrés Arias

    2018-09-01

    Full Text Available Electric Vehicles (EVs represent a significant option that contributes to improve the mobility and reduce the pollution, leaving a future expectation in the merchandise transportation sector, which has been demonstrated with pilot projects of companies operating EVs for products delivering. In this work a new approach of EVs for merchandise transportation considering the location of Electric Vehicle Charging Stations (EVCSs and the impact on the Power Distribution System (PDS is addressed. This integrated planning is formulated through a mixed integer non-linear mathematical model. Test systems of different sizes are designed to evaluate the model performance, considering the transportation network and PDS. The results show a trade-off between EVs routing, PDS energy losses and EVCSs location.

  12. Shippingport Atomic Power Station Operating Experience, Developments and Future Plans

    International Nuclear Information System (INIS)

    Feinroth, H.; Oldham, G.M.; Stiefel, J.T.

    1963-01-01

    This paper describes and evaluates five years of operation and test of the Shippingport Atomic Power Station and discusses the current technical developments and future plans of the Shippingport programme. This programme is directed towards development of the basic technology of light-water reactors to provide the basis for potential reduction in the costs of nuclear power. The Shippingport reactor plant has operated for over five years and has been found to integrate readily into a utility system either as a base load or peak load unit. Plant component performance has been reliable. There have been no problems in contamination or waste disposal. Access to primary coolant components for maintenance has been good, demonstrating the integrity of fuel elements. Each of the three refuelling operations performed since start-up of Shippingport has required successively less time to accomplish. Recently, the third seed was refuelled in 32 working days, about one quarter the time required for the first refuelling. The formal requirements of personnel training, written administrative procedures, power plant manuals, etc., which have been a vital factor in the successful implementation of the Shippingport programme, are described. The results obtained from the comprehensive test programme carried out at Shippingport are compared with calculations, and good agreement has been obtained. Reactor core performance, plant stability, and response to load changes, fuel element and control rod performance, long-term effects such as corrosion and radiation level build-up, component performance, etc., are discussed in this paper. The principal objective of the current and future programmes of the Shippingport Project in advancing the basic technology of water-cooled reactors is discussed. This programme includes the continued operation of the Shippingport plant, and the development, design, manufacture and test operation of a long-life, highpower density second core - Core 2. At its

  13. Nova isolates noise to quieten stations

    International Nuclear Information System (INIS)

    Milner, G.J.; Frank, L.D.

    1993-01-01

    This paper reviews a technique developed by Nova Corp., to help isolate and measure the acoustic power of individual components in a pipeline compressor and pumping station. The procedure calculates the sound pressure levels of each piece of equipment independently. Based on these measurements, a prediction can be made of the effect of various types of noise treatment techniques on the overall sound levels currently generated or proposed in a future project. This paper describes the equipment to measure the sound levels, techniques for actually measuring the compressor station or equipment area, and techniques used to generate a remediation plan

  14. Shippingport station decommissioning project technology transfer program

    International Nuclear Information System (INIS)

    Pasquini, L.A.

    1986-01-01

    The purpose of the Shippingport Station Decommissioning Project (SSDP) is to place the Shippingport Atomic Power Station in a long-term radiologically safe condition following defueling of the reactor, to perform decommissioning in such a manner as to demonstrate to the nuclear industry the application of decommissioning procedures to a large scale nuclear power plant, and to provide useful planning data for future decommissioning projects. This paper describes the Technology Transfer Program for collecting and archiving the decommissioning data base and its availability to the nuclear industry

  15. Beyond defense-in-depth: cost and funding of state and local government radiological emergency response plans and preparedness in support of commercial nuclear power stations

    International Nuclear Information System (INIS)

    Salomon, S.N.

    1979-10-01

    Inadequate, sporadic, uncertain and frustrating are words local, state and Federal officials use to describe the current hodgepodge funding approach to State and local government radiological emergency response plans and preparedeness in support of commercial nuclear power stations. The creation of a Radiological Emergency Response Plans and Preparedness Fund for State and Local Government is offered as a preferred solution. Monies for the Fund could be derived from a one time Fee of $1 million levied on the operator of each nuclear power station. Every five years, adjustments could be made in the Fee to assure full recovery of costs because of inflation, revised criteria and other cost related factors. Any surplus would be refunded to the utilities. Any state that has obtained NRC concurrence or is in the process could be reimbursed for previous expenditures up to two years prior to NRC concurrence. Concurrence in all state and local government plans is the objective of the funding program. The Fund should be administered by the Nuclear Regulatory Commission. The report also discusses actions by Federal and state agencies and points to long range considerations, such as a training institute, including transportation and non-commercial and other fixed nuclear facilities, where preparedness could be enhanced by a coherent funding mechanism. All recommendations are based on an inquiry by the Office of state Programs, NRC, into the historical and future costs and funding of radiological emergency response plans and preparedness at the state and local government levels and are derived from discussions with many local, State and Federal officials

  16. Planning Systems for Distributed Operations

    Science.gov (United States)

    Maxwell, Theresa G.

    2002-01-01

    This viewgraph representation presents an overview of the mission planning process involving distributed operations (such as the International Space Station (ISS)) and the computer hardware and software systems needed to support such an effort. Topics considered include: evolution of distributed planning systems, ISS distributed planning, the Payload Planning System (PPS), future developments in distributed planning systems, Request Oriented Scheduling Engine (ROSE) and Next Generation distributed planning systems.

  17. Space Station power system issues

    International Nuclear Information System (INIS)

    Giudici, R.J.

    1985-01-01

    Issues governing the selection of power systems for long-term manned Space Stations intended solely for earth orbital missions are covered briefly, drawing on trade study results from both in-house and contracted studies that have been conducted over nearly two decades. An involvement, from the Program Development Office at MSFC, with current Space Station concepts began in late 1982 with the NASA-wide Systems Definition Working Group and continued throughout 1984 in support of various planning activities. The premise for this discussion is that, within the confines of the current Space Station concept, there is good reason to consider photovoltaic power systems to be a venerable technology option for both the initial 75 kW and 300 kW (or much greater) growth stations. The issue of large physical size required by photovoltaic power systems is presented considering mass, atmospheric drag, launch packaging and power transmission voltage as being possible practicality limitations. The validity of searching for a cross-over point necessitating the introduction of solar thermal or nuclear power system options as enabling technologies is considered with reference to programs ranging from the 4.8 kW Skylab to the 9.5 gW Space Power Satellite

  18. Technical assessment of Mir-1 life support hardware for the international space station

    Science.gov (United States)

    Mitchell, K. L.; Bagdigian, R. M.; Carrasquillo, R. L.; Carter, D. L.; Franks, G. D.; Holder, D. W., Jr.; Hutchens, C. F.; Ogle, K. Y.; Perry, J. L.; Ray, C. D.

    1994-01-01

    NASA has been progressively learning the design and performance of the Russian life support systems utilized in their Mir space station. In 1992, a plan was implemented to assess the benefits of the Mir-1 life support systems to the Freedom program. Three primary tasks focused on: evaluating the operational Mir-1 support technologies and understanding if specific Russian systems could be directly utilized on the American space station and if Russian technology design information could prove useful in improving the current design of the planned American life support equipment; evaluating the ongoing Russian life support technology development activities to determine areas of potential long-term application to the U.S. space station; and utilizing the expertise of their space station life support systems to evaluate the benefits to the current U.S. space station program which included the integration of the Russian Mir-1 designs with the U.S. designs to support a crew of six.

  19. Gasket-holder to put in place gaskets for connection of pipes with clamp fittings

    International Nuclear Information System (INIS)

    Fiori, R.

    1989-01-01

    Gasket-holder comprising 2 arms with tongues holding the gasket and fixing devices on a pipe clamp fitting and centering means. Application is made to fit circular gaskets on pipe with conic end in adverse environment [fr

  20. Development of in-service inspection plans for nuclear components at the Surry 1 nuclear power station

    International Nuclear Information System (INIS)

    Vo, T.V.; Simonen, F.A.; Doctor, S.R.; Smith, B.W.; Gore, B.F.

    1993-01-01

    As part of the nondestructive evaluation reliability program sponsored by the US Nuclear Regulatory Commission at Pacific Northwest Laboratory, a methodology has been developed for establishing in-service inspection priorities of nuclear power plant components. The method uses results of probabilistic risk assessment in conjunction with the techniques of failure modes and effects analysis to identify and prioritize the most risk-important systems and components for inspection at nuclear power plants. Surry nuclear power station unit 1 was selected for demonstrating the methodology. The specific systems selected for analysis were the reactor pressure vessel, the reactor coolant, the low pressure injection including the accumulators, and the auxiliary feedwater. The results provide a risk-based ranking of components that can be used to establish a prioritization of the components and a basis for developing improved in-service inspection plans at nuclear power plants

  1. (Shippingport Atomic Power Station). Quarterly operating report, third quarter 1980

    Energy Technology Data Exchange (ETDEWEB)

    Zagorski, J. F.

    1980-01-01

    At the beginning of the third quarter of 1980, the Shippingport Atomic Power Station was operating with the 1A, 1B, 1C, and 1D reactor coolant loops and the 1AC and 1BD purification loops in service. During the quarter, the Station was operated for Duquesne Light Company System grid including base load and swing load operation. Twelve (12) planned swing load operations were performed on the LWBR Core this quarter to complete the LWBR operating plan of fifty (50) during this operating phase. The Station was shutdown on September 12 for the Fall 1980 Shutdown and remained in this mode through the end of the quarter. The LWBR Core has generated 18,297.98 EFPH from start-up through the end of the quarter. There were no radioactive liquid discharges from the Radioactive Waste Processing System to the river this quarter. The radioactive liquid waste effluent line to the river remained blanked off to prevent inadvertent radioactive liquid waste discharges. During the quarter, approximately 0.001 curies of Xe 133 activity were released from the station. The radioactivity released from Shippingport Station is far too small to have any measurable effect on the general background environmental radioactivity outside the plant.

  2. Timing of umbilical cord clamping among infants born at 22 through 27 weeks' gestation.

    Science.gov (United States)

    Backes, C H; Huang, H; Iams, J D; Bauer, J A; Giannone, P J

    2016-01-01

    To investigate the safety, feasibility and efficacy of delayed cord clamping (DCC) compared with immediate cord clamping (ICC) at delivery among infants born at 22 to 27 weeks' gestation. This was a pilot, randomized, controlled trial in which women in labor with singleton pregnancies at 22 to 27 weeks' gestation were randomly assigned to ICC (cord clamped at 5 to 10 s) or DCC (30 to 45 s). Forty mother-infant pairs were randomized. Infants in the ICC and DCC groups had mean gestational ages (GA) of 24.6 and 24.4 weeks, respectively. No differences were observed between the groups across all available safety measures, although infants in the DCC group had higher admission temperatures than infants in the ICC group (97.4 vs. 96.2 °F, P=0.04). During the first 24 h of life, blood pressures were lower in the ICC group than in the DCC group (P<0.05), despite a threefold greater incidence of treatment for hypotension (45% vs. 12%, P<0.01). Infants in the ICC group had increased numbers of red blood transfusions (in first 28 days of life) than infants in DCC group (4.1±3.9 vs. 2.8±2.2, P=0.04). Among infants born at an average GA of 24 weeks', DCC appears safe, logistically feasible, and offers hematological and circulatory advantages compared with ICC. A more comprehensive appraisal of this practice is needed.

  3. Pituitary-gonadal and pituitary-thyroid axis hormone concentrations before and during a hypoglycemic clamp after sleep deprivation in healthy men.

    Directory of Open Access Journals (Sweden)

    Kamila Jauch-Chara

    Full Text Available Total sleep deprivation (TSD exerts strong modulatory effects on the secretory activity of endocrine systems that might be related to TSD-induced challenges of cerebral glucose metabolism. Here, we investigate whether TSD affects the course of male pituitary-gonadal and pituitary-thyroid axis related hormones during a subsequent 240-min hypoglycemic clamp. Ten healthy men were tested on 2 different conditions, TSD and 7-hour regular sleep. Circulating concentrations of total testosterone, prolactin (PRL, thyroid stimulating hormone (TSH, free triiodothyronine (fT3, and free thyroxin (fT4 were measured during baseline and a subsequent hypoglycemic clamp taking place in the morning. Basal, i.e. at 07:00 am measured, concentrations of total testosterone (P = 0.05 and PRL (P<0.01 were lower while the values of TSH (P = 0.02, fT3 (P = 0.08, and fT4 (P = 0.04 were higher after TSD as compared to regular sleep. During the subsequent hypoglycemic clamp (all measurements from baseline to the end of the clamp analyzed total testosterone concentrations in the regular sleep (P<0.01 but not in the TSD condition (P = 0.61 decreased, while PRL levels increased (P = 0.05 irrespectively of the experimental condition (P = 0.31. TSH concentrations decreased during hypoglycemia (P<0.01, with this decrease being more pronounced after TSD (P = 0.04. However, at the end of the hypoglycemic clamp concentrations all of the above mentioned hormones did not differ between the two sleep conditions. Our data indicate a profound influence of TSD on male pituitary-gonadal and pituitary-thyroid axis hormones characterized by reduced basal testosterone and PRL levels and increased TSH levels. However, since concentrations of these hormones measured at the end of the 240-min hypoglycemic clamp were not affected by TSD it can be speculated that the influence of TSD on the two endocrine axes is rather short lived or does not interact in an additive

  4. Infrared spectromicroscopy and magneto-optical imaging stations at SPring-8

    CERN Document Server

    Kimura, S; Sada, T; Okuno, M; Matsunami, M; Shinoda, K; Kimura, H; Moriwaki, T; Yamagata, M; Kondo, Y; Yoshimatsu, Y; Takahashi, T; Fukui, K; Kawamoto, T; Ishikawa, T

    2001-01-01

    At the BL43IR of SPring-8, infrared microanalysis on various kinds of solid specimens under multiple environments with a spatial resolution smaller than 10 mu m in diameter is planned in the infrared region. In order to perform such analysis, two different stations, a multipurpose spectromicroscopy apparatus and a magneto-optical imaging one have been constructed. Measurements on the spatial two-dimensional cross-section of the infrared beam at the spectromicroscopy station have proven that the stations have a good prospective feature in the performance.

  5. Battery charger with a capacitor-diode clamped LLC resonant converter

    OpenAIRE

    Tsang, C.; Bingham, C.; Foster, M. P.; Stone, D.; Leech, J.

    2016-01-01

    The paper proposes a novel battery charger through use of\\ud two serially-connected LLC resonant converters. The first\\ud stage utilises a capacitor-diode clamped LLC resonant\\ud converter which allows operation in both constant voltage\\ud (CV) and constant current (CC) modes, as found in most\\ud battery chargers, to be realised, whilst the second stage\\ud provides the necessary gain and line and load regulation. A\\ud design example is included that demonstrates the resulting\\ud converter top...

  6. Computer functions in overall plant control of candu generating stations

    International Nuclear Information System (INIS)

    Chou, Q.B.; Stokes, H.W.

    1976-01-01

    System Planning Specifications form the basic requirements for the performance of the plant including its response to abnormal situations. The rules for the computer control programs are devised from these, taking into account limitations imposed by the reactor, heat transport and turbine-generator systems. The paper outlines these specifications and the limitations imposed by the major items of plant equipment. It describes the functions of each of the main programs, their interactions and the control modes used in the existing Ontario Hydro's nuclear station or proposed for future stations. Some simulation results showing the performance of the overall unit control system and plans for future studies are discussed. (orig.) [de

  7. Reload shutdown for Nuclear Power Stations in spain in 2003

    International Nuclear Information System (INIS)

    2004-01-01

    Regarding time reductions in fuel reloading at Spanish nuclear power stations, the Spanish Nuclear Security Council (CSN), at the request of the Spanish Finance and Treasury Department of the Chamber of Deputies, delivered an instruction, by which power station's owners were urged to establish a detailed planning of reload operations. This article includes the results of this instruction. (Author) 6 refs

  8. Reserving Charging Decision-Making Model and Route Plan for Electric Vehicles Considering Information of Traffic and Charging Station

    Directory of Open Access Journals (Sweden)

    Haoming Liu

    2018-04-01

    Full Text Available With the advance of battery energy technology, electric vehicles (EV are catching more and more attention. One of the influencing factors of electric vehicles large-scale application is the availability of charging stations and convenience of charging. It is important to investigate how to make reserving charging strategies and ensure electric vehicles are charged with shorter time and lower charging expense whenever charging request is proposed. This paper proposes a reserving charging decision-making model for electric vehicles that move to certain destinations and need charging services in consideration of traffic conditions and available charging resources at the charging stations. Besides, the interactive mechanism is described to show how the reserving charging system works, as well as the rolling records-based credit mechanism where extra charges from EV is considered to hedge default behavior. With the objectives of minimizing driving time and minimizing charging expenses, an optimization model with two objective functions is formulated. Then the optimizations are solved by a K shortest paths algorithm based on a weighted directed graph, where the time and distance factors are respectively treated as weights of corresponding edges of transportation networks. Case studies show the effectiveness and validity of the proposed route plan and reserving charging decision-making model.

  9. Balance control strategy of two-amplitude actively clamped resonant DC-Link inverter clamping voltage%双幅有源箝位谐振直流环节逆变器箝位电压平衡控制策略

    Institute of Scientific and Technical Information of China (English)

    陈沁野; 张德华; 侯尧杰

    2012-01-01

    Aiming at the big loss of the traditional clamping voltage balance control strategies, in two-amplitude actively clamped resonant DC-LINK inverter, the work process of DC link was analyzed. In order to keep the clamp capacitor voltage balance the value set in DC-link work, no short-circuit control was proposed.The DC-link of inverter was calculated by Mathcad. The loss of two modes of short-circuit control and no short-circuit control were compared.Under the no short-circuit control and voltage ripple is not be greater than twenty percent, the parameters of the clamp capacitor were calculated. The results indicate that, the micro-power ACRDCLI clamping voltage balance use no short-circuit control,that can reduce the loss of the DC link and can use thin-film capacitor as a clamp capacitor to achieve the micro-power ACRDCLI low loss and iong life requirements.%针对微型功率双幅有源箝位谐振直流环节逆变器在正常工作过程中,传统箝位电压平衡母线短路控制策略带来损耗大的问题,开展了直流环节工作过程的分析,针对直流环节正常工作的情况下,箝位电容电压必须能平衡在设定值,提出了箝位电压平衡母线无短路控制策略,根据给出的损耗估算方法,通过Mathcad计算,对比了母线短路控制和无短路控制两种方式下的损耗,同时计算出了母线无短路控制箝位电容电压纹波不大于20%下的箝位电容参数.研究结果表明:微型功率ACRDCLI箝位电压平衡采用母线无短线控制,不但可以减少双幅有源箝位谐振直流环节逆变器的损耗,并且可以使用薄膜电容作为箝位电容,以达到微型功率ACRDCLI损耗低、寿命长的要求.

  10. Hda monomerization by ADP binding promotes replicase clamp-mediated DnaA-ATP hydrolysis.

    Science.gov (United States)

    Su'etsugu, Masayuki; Nakamura, Kenta; Keyamura, Kenji; Kudo, Yuka; Katayama, Tsutomu

    2008-12-26

    ATP-DnaA is the initiator of chromosomal replication in Escherichia coli, and the activity of DnaA is regulated by the regulatory inactivation of the DnaA (RIDA) system. In this system, the Hda protein promotes DnaA-ATP hydrolysis to produce inactive ADP-DnaA in a mechanism that is mediated by the DNA-loaded form of the replicase sliding clamp. In this study, we first revealed that hda translation uses an unusual initiation codon, CUG, located downstream of the annotated initiation codon. The CUG initiation codon could be used for restricting the Hda level, as this initiation codon has a low translation efficiency, and the cellular Hda level is only approximately 100 molecules per cell. Hda translated using the correct reading frame was purified and found to have a high RIDA activity in vitro. Moreover, we found that Hda has a high affinity for ADP but not for other nucleotides, including ATP. ADP-Hda was active in the RIDA system in vitro and stable in a monomeric state, whereas apo-Hda formed inactive homomultimers. Both ADP-Hda and apo-Hda could form complexes with the DNA-loaded clamp; however, only ADP-Hda-DNA-clamp complexes were highly functional in the following interaction with DnaA. Formation of ADP-Hda was also observed in vivo, and mutant analysis suggested that ADP binding is crucial for cellular Hda activity. Thus, we propose that ADP is a crucial Hda ligand that promotes the activated conformation of the protein. ADP-dependent monomerization might enable the arginine finger of the Hda AAA+ domain to be accessible to ATP bound to the DnaA AAA+ domain.

  11. Onboard Short Term Plan Viewer

    Science.gov (United States)

    Hall, Tim; LeBlanc, Troy; Ulman, Brian; McDonald, Aaron; Gramm, Paul; Chang, Li-Min; Keerthi, Suman; Kivlovitz, Dov; Hadlock, Jason

    2011-01-01

    Onboard Short Term Plan Viewer (OSTPV) is a computer program for electronic display of mission plans and timelines, both aboard the International Space Station (ISS) and in ISS ground control stations located in several countries. OSTPV was specifically designed both (1) for use within the limited ISS computing environment and (2) to be compatible with computers used in ground control stations. OSTPV supplants a prior system in which, aboard the ISS, timelines were printed on paper and incorporated into files that also contained other paper documents. Hence, the introduction of OSTPV has both reduced the consumption of resources and saved time in updating plans and timelines. OSTPV accepts, as input, the mission timeline output of a legacy, print-oriented, UNIX-based program called "Consolidated Planning System" and converts the timeline information for display in an interactive, dynamic, Windows Web-based graphical user interface that is used by both the ISS crew and ground control teams in real time. OSTPV enables the ISS crew to electronically indicate execution of timeline steps, launch electronic procedures, and efficiently report to ground control teams on the statuses of ISS activities, all by use of laptop computers aboard the ISS.

  12. Potassium Chloride Versus Voltage Clamp Contractures in Ventricular Muscle

    Science.gov (United States)

    Morad, M.; Reeck, S.; Rao, M.

    1981-01-01

    In frog ventricle, developed tension was markedly larger in response to depolarization caused by a voltage clamp step than to depolarization induced by high concentrations of potassium chloride. Measurement of extracellular potassium activity at the surface and at the depth of muscle during the development of contractures showed that the diffusion of potassium is much slower than the spread of depolarization through the cross section of muscle. These two observations suggest that competition between the depolarizing and the negative inotropic effects of an increase in the extracellular potassium ion concentration may determine the time course and magnitude of contractile tension in heart muscle.

  13. Overmodulation of n-level three-leg DC-AC diode-clamped converters with comprehensive capacitor voltage balance

    DEFF Research Database (Denmark)

    Busquets-Monge, S.; Maheshwari, Ram Krishan; Munk-Nielsen, Stig

    2013-01-01

    This paper presents a novel PWM strategy for nlevel three-leg semiconductor-clamped dc-ac converters in the overmodulation region, with dc-link capacitor voltage balance in every switching cycle. The strategy is based on the virtual-vector concept. Suitable reference vector trajectories are selec......This paper presents a novel PWM strategy for nlevel three-leg semiconductor-clamped dc-ac converters in the overmodulation region, with dc-link capacitor voltage balance in every switching cycle. The strategy is based on the virtual-vector concept. Suitable reference vector trajectories...

  14. Enhanced static ground power unit based on flying capacitor based h-bridge hybrid active-neutral-point-clamped converter

    DEFF Research Database (Denmark)

    Abarzadeh, Mostafa; Madadi Kojabadi, Hossein; Deng, Fujin

    2016-01-01

    Static power converters have various applications, such as static ground power units (GPUs) for airplanes. This study proposes a new configuration of a static GPU based on a novel nine-level flying capacitor h-bridge active-neutral-point-clamped (FCHB_ANPC) converter. The main advantages of the p......Static power converters have various applications, such as static ground power units (GPUs) for airplanes. This study proposes a new configuration of a static GPU based on a novel nine-level flying capacitor h-bridge active-neutral-point-clamped (FCHB_ANPC) converter. The main advantages...

  15. Loss Distribution Analysis of Three-Level Active Neutral-Point-Clamped (3L-ANPC) Converter with Different PWM Strategies

    DEFF Research Database (Denmark)

    Zhang, Gang; Yang, Yongheng; Iannuzzo, Francesco

    2016-01-01

    The three-level (3L) Active Neutral-Point-Clamped (ANPC) topology has been introduced to resolve the uneven loss distribution issue in the classical 3L Neutral-Point-Clamped (NPC) topology. This Pulse-Width-Modulation (PWM) strategy is then an important means to fully explore the potential benefits...... are separated in order to improve the loss distribution among the power devices. A comparison between the proposed strategy and other major PWM strategies for the loss distribution is also carried out in this paper. Benchmarking results show that the proposed strategy has effective and superior performance...

  16. Characterization of the insulin sensitivity of ghrelin receptor KO mice using glycemic clamps

    Directory of Open Access Journals (Sweden)

    Morgan Kristen

    2011-01-01

    Full Text Available Abstract Background We and others have demonstrated previously that ghrelin receptor (GhrR knock out (KO mice fed a high fat diet (HFD have increased insulin sensitivity and metabolic flexibility relative to WT littermates. A striking feature of the HFD-fed GhrR KO mouse is the dramatic decrease in hepatic steatosis. To characterize further the underlying mechanisms of glucose homeostasis in GhrR KO mice, we conducted both hyperglycemic (HG and hyperinsulinemic-euglycemic (HI-E clamps. Additionally, we investigated tissue glucose uptake and specifically examined liver insulin sensitivity. Results Consistent with glucose tolerance-test data, in HG clamp experiments, GhrR KO mice showed a reduction in glucose-stimulated insulin release relative to WT littermates. Nevertheless, a robust 1st phase insulin secretion was still achieved, indicating that a healthy β-cell response is maintained. Additionally, GhrR KO mice demonstrated both a significantly increased glucose infusion rate and significantly reduced insulin requirement for maintenance of the HG clamp, consistent with their relative insulin sensitivity. In HI-E clamps, both LFD-fed and HFD-fed GhrR KO mice showed higher peripheral insulin sensitivity relative to WT littermates as indicated by a significant increase in insulin-stimulated glucose disposal (Rd, and decreased hepatic glucose production (HGP. HFD-fed GhrR KO mice showed a marked increase in peripheral tissue glucose uptake in a variety of tissues, including skeletal muscle, brown adipose tissue and white adipose tissue. GhrR KO mice fed a HFD also showed a modest, but significant decrease in conversion of pyruvate to glucose, as would be anticipated if these mice displayed increased liver insulin sensitivity. Additionally, the levels of UCP2 and UCP1 were reduced in the liver and BAT, respectively, in GhrR KO mice relative to WT mice. Conclusions These results indicate that improved glucose homeostasis of GhrR KO mice is

  17. Planning for Bike Share Connectivity to Rail Transit

    Science.gov (United States)

    Griffin, Greg Phillip; Sener, Ipek Nese

    2016-01-01

    Bike sharing can play a role in providing access to transit stations and then to final destinations, but early implementation of these systems in North America has been opportunistic rather than strategic. This study evaluates local intermodal plan goals using trip data and associated infrastructure such as transit stops and bike share station locations in Austin, Texas, and Chicago, Illinois. Bike sharing use data from both cities suggest a weak relationship with existing rail stations that could be strengthened through collaborative, intermodal planning. The study suggests a planning framework and example language that could be tailored to help address the linkage between bike sharing and transit. Rather than an exhaustive study of the practice, this study provides evidence from these two cities that identify opportunities to improve intermodal planning. Cities that are planning or expanding a bike sharing system should consider carefully how to leverage this mode with existing modes of transport. Regardless of a city’s status in implementing a bike sharing system, planners can leverage information on existing transport systems for planning at regional and local levels. PMID:27872554

  18. Improvements in operational safety performance of the Magnox power stations

    Energy Technology Data Exchange (ETDEWEB)

    Marchese, C.J. [BNFL Magnox Generation, Berkeley (United Kingdom)

    2000-10-01

    In the 43 years since commencement of operation of Calder Hall, the first Magnox power station, there remain eight Magnox stations and 20 reactors still in operation, owned by BNFL Magnox Generation. This paper describes how the operational safety performance of these stations has significantly improved over the last ten years. This has been achieved against a background of commercial competition introduced by privatization and despite the fact that the Magnox base design belongs to the past. Finally, the company's future plans for continued improvements in operational safety performance are discussed. (author)

  19. Planning of activities in the Laguna Verde Central planning at 12 weeks

    International Nuclear Information System (INIS)

    Chimalpopoca, C.

    2007-01-01

    The universe of works that are carried out in a nuclear facility to maintain effective the structures, systems and components require of a continuous analysis, in the order of the maintenance frequencies that can be of the preventive, predictive or corrective type. Each component is associated to reserve parts, readiness of systems, in fulfillment to the operation technical specifications, to the environment of the one work; each component requires of a planning level, where it is distinguished with clarity when they are executed, in the operation stage, stop or recharge. This work has as end to show like the activities are planned during the operation, using planning methods to twelve weeks, where the reach of the task is conceptualized, operative requirements, of reserve parts, of the work environment analysis, of those radiological conditions, of the authorizations for their execution, the same execution and the evaluation post work like a technique to maintain in continuous improvement the tasks of the maintenance of the Units of the Power station. A motor valve to be worked in its internals requires access to the work point, it requires bill of the system, electric disconnection, maneuvers to disassemble actuators and retirement of thermal isolation if it applies, reserve parts of the caps joints, control mechanisms, personal, tools, radiological control. The success of the continuous operation of a power station is in the planning quality, the attention of each one of the details to assure that the components, structures and components stay effective to make their function when they are demanded. The planning task requires of experience and knowledge of each some of the components, the task of planning of activities and its execution is multidisciplinary This work has that purpose, to show the planning tools in the Laguna Verde Nuclear Power station, under the concept of twelve weeks. (Author)

  20. Space station automation and robotics study. Operator-systems interface

    Science.gov (United States)

    1984-01-01

    This is the final report of a Space Station Automation and Robotics Planning Study, which was a joint project of the Boeing Aerospace Company, Boeing Commercial Airplane Company, and Boeing Computer Services Company. The study is in support of the Advanced Technology Advisory Committee established by NASA in accordance with a mandate by the U.S. Congress. Boeing support complements that provided to the NASA Contractor study team by four aerospace contractors, the Stanford Research Institute (SRI), and the California Space Institute. This study identifies automation and robotics (A&R) technologies that can be advanced by requirements levied by the Space Station Program. The methodology used in the study is to establish functional requirements for the operator system interface (OSI), establish the technologies needed to meet these requirements, and to forecast the availability of these technologies. The OSI would perform path planning, tracking and control, object recognition, fault detection and correction, and plan modifications in connection with extravehicular (EV) robot operations.

  1. Error management process for power stations

    International Nuclear Information System (INIS)

    Hirotsu, Yuko; Takeda, Daisuke; Fujimoto, Junzo; Nagasaka, Akihiko

    2016-01-01

    The purpose of this study is to establish 'error management process for power stations' for systematizing activities for human error prevention and for festering continuous improvement of these activities. The following are proposed by deriving concepts concerning error management process from existing knowledge and realizing them through application and evaluation of their effectiveness at a power station: an entire picture of error management process that facilitate four functions requisite for maraging human error prevention effectively (1. systematizing human error prevention tools, 2. identifying problems based on incident reports and taking corrective actions, 3. identifying good practices and potential problems for taking proactive measures, 4. prioritizeng human error prevention tools based on identified problems); detail steps for each activity (i.e. developing an annual plan for human error prevention, reporting and analyzing incidents and near misses) based on a model of human error causation; procedures and example of items for identifying gaps between current and desired levels of executions and outputs of each activity; stages for introducing and establishing the above proposed error management process into a power station. By giving shape to above proposals at a power station, systematization and continuous improvement of activities for human error prevention in line with the actual situation of the power station can be expected. (author)

  2. Space station as a vital focus for advancing the technologies of automation and robotics

    Science.gov (United States)

    Varsi, Giulio; Herman, Daniel H.

    1988-01-01

    A major guideline for the design of the U.S. Space Station is that the Space Station address a wide variety of functions. These functions include the servicing of unmanned assets in space, the support of commercial labs in space and the efficient management of the Space Station itself; the largest space asset. The technologies of Automation and Robotics have the promise to help in reducing Space Station operating costs and to achieve a highly efficient use of the human in space. The use of advanced automation and artificial intelligence techniques, such as expert systems, in Space Station subsystems for activity planning and failure mode management will enable us to reduce dependency on a mission control center and could ultimately result in breaking the umbilical link from Earth to the Space Station. The application of robotic technologies with advanced perception capability and hierarchical intelligent control to servicing system will enable the servicing of assets either in space or in situ with a high degree of human efficiency. The results of studies leading toward the formulation of an automation and robotics plan for Space Station development are presented.

  3. Significance of Shrinkage Induced Clamping Pressure in Fiber-Matrix Bonding in Cementitious Composite Materials

    DEFF Research Database (Denmark)

    Stang, Henrik

    1996-01-01

    used in high performance cementitious composite materials.Assuming a Coulomb type of friction on the fiber/matrix interface andusing typical values for the frictional coefficient it is shownthat the shrinkage induced clamping pressure could be one of the mostimportant factors determining the frictional...

  4. Louisiana Speaks Transportation Option C Transit Stations, UTM Zone 15N NAD 83, Louisiana Recovery Authority (2007), [louisiana_speaks_transportation_option_c_transit_stations

    Data.gov (United States)

    Louisiana Geographic Information Center — This GIS shapefile data illustrates potential fixed-transit stations included in the Louisiana Speaks Regional Plan community growth option of compact development...

  5. Trans-Z-source Neutral Point Clamped inverter

    DEFF Research Database (Denmark)

    Mo, W.; Loh, P. C.; Li, D.

    2012-01-01

    Transformer based Z-source (trans-Z-source) inverters are recently proposed by extending the traditional Z-source inverter with higher buck-boost capability as well as reducing the passive components at the same time. Multi-Level Z-source inverters are single-stage topological solutions used...... for buck-boost energy conversion with all the favourable advantages of multi-level switching retained. This paper presents three-level trans-Z-source Neutral Point Clamped (NPC) inverter topology, which achieves both the advantages of trans-Z-source and three-level NPC inverter configuration. With proper...... modulation scheme, the three-level trans-Z-source inverter can function with minimum of six device commutations per half carrier cycle (same as the traditional buck NPC inverter), while maintaining to produce the designed volt-sec average and inductive voltage boosting at ac output terminals. The designed...

  6. From understanding cellular function to novel drug discovery: the role of planar patch-clamp array chip technology

    Directory of Open Access Journals (Sweden)

    Christophe ePy

    2011-10-01

    Full Text Available All excitable cell functions rely upon ion channels that are embedded in their plasma membrane. Perturbations of ion channel structure or function result in pathologies ranging from cardiac dysfunction to neurodegenerative disorders. Consequently, to understand the functions of excitable cells and to remedy their pathophysiology, it is important to understand the ion channel functions under various experimental conditions – including exposure to novel drug targets. Glass pipette patch-clamp is the state of the art technique to monitor the intrinsic and synaptic properties of neurons. However, this technique is labor-intensive and has low data throughput. Planar patch-clamp chips, integrated into automated systems, offer high throughputs but are limited to isolated cells from suspensions, resulting in questionable models of true physiological function, and are unsuitable for studies involving neuronal communication. Multi-electrode arrays (MEA, in contrast, have the ability to monitor network activity by measuring local field potentials from multiple extracellular sites, but specific ion channel activity is challenging to extract from these multiplexed signals. Here we describe a novel planar patch-clamp chip technology that enables the simultaneous high resolution electrophysiological interrogation of individual neurons at multiple sites in synaptically connected neuronal networks, thereby combining the advantages of MEA and patch-clamp techniques. Each neuron can be probed through an aperture that connects to a dedicated subterranean microfluidic channel. Neurons growing in networks are aligned to the apertures by physisorbed or chemisorbed chemical cues. In this review, we describe the design and fabrication process of these chips, the approach to the chemical patterning for cell placement, and present physiological data from cultured neuronal cells.

  7. Characterization of the mandible Atta laevigata and the bioinspiration for the development of a biomimetic surgical clamp

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Thays Obando; Elzubair, Amal; Araújo, Leonardo Sales; Camargo, Sergio Alvaro de Souza; Almeida, Luiz Henrique, E-mail: thaysdesigner@hotmail.com [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEMM/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Metalúrgica e de Materiais; Souza, Jorge Luiz Pereira [Instituto Nacional de Pesquisas da Amazônia, Manaus, AM (Brazil)

    2017-11-15

    Approximately thousand years ago it was reported the use of mandibles of ants for suture. In this sense, bioinspired components, as absorbable surgical clamps, can be designed. This study is aimed to characterize the mandible of the ant Atta laevigata in order to help the selection of candidate biomaterials for application as surgical clamps. Three pairs of mandibles were used and ten nanoindenations were performed in each pair. The average hardness for the samples in the internal and external regions were 0.36 ± 0.06 GPa and 0.19 ± 0.04 GPa, respectively and the average elastic modulus for the internal and external regions were 6.16 ± 0.23 GPa and 2.74 ± 0.44 GPa, respectively. The morphology of the mandible was observed in detail by scanning electron microscopy, as well as Energy-dispersive X-ray spectroscopy. The average roughnesses on the internal and external regions, measured by atomic force microscopy, were 6.73 ± 0.90 nm and 11.87 ± 1.42 nm, respectively. From these results, it was possible to identify biomaterials that mimic the mandible behaviour for surgical clamp. (author)

  8. Louisiana Speaks Transportation Option B Transit Stations, UTM Zone 15N NAD 83, Louisiana Recovery Authority (2007), [louisiana_speaks_transportation_option_b_transit_stations

    Data.gov (United States)

    Louisiana Geographic Information Center — This GIS shapefile data illustrates potential fixed-transit stations included in the Louisiana Speaks Regional Plan community growth option of compact and dispersed...

  9. Reducing radiation exposures at nuclear power plants using virtual job planning

    International Nuclear Information System (INIS)

    Verzilov, Y.; Husain, A.

    2014-01-01

    Advanced Dose Exposure Planning Tool (ADEPT) is an innovative solution for assisting nuclear station staff to effectively minimize worker dose during inspection and maintenance activities and to improve ALARA job planning. ADEPT combines visualization and simulation of the radioactive environment at a nuclear station to estimate worker dose. It allows users to walk through a virtual job plan and receive a live radiation dose estimate for the planned work. (author)

  10. Chilean Antarctic Stations on King George Island

    Directory of Open Access Journals (Sweden)

    Katsutada Kaminuma

    2000-07-01

    Full Text Available The purpose of my visit to Chilean Antarctic Stations was to assess the present status of geophysical observations and research, as the South Shetland Island, West Antarctica, where the stations are located, are one of the most active tectonic regions on the Antarctic plate. The Instituto Antartico Chileno (INACH kindly gave me a chance to stay in Frei/Escudero Bases as an exchange scientist under the Antarctic Treaty for two weeks in January 2000. I stayed in Frei Base as a member of a geological survey group named "Tectonic Evolution of the Antarctic Peninsula" which was organized by Prof. F. Herve, University of Chile, from January 05 to 19,2000. All my activity in the Antarctic was organized by INACH. During my stay in Frei Base, I also visited Bellingshausen (Russian, Great Wall (China and Artigas (Uruguay stations. All these stations are located within walking distance of Frei Base. King Sejong Station (Korea, located 10km east from Frei Base, and Jubany Base (Argentine, another 6km south-east from King Sejong Station, were also visited with the aid of a zodiac boat that was kindly operated for us by King Sejong Station. All stations except Escudero Base carry out meteorological observations. The seismological observations in Frei Base are operated by Washington State University of the U. S. monitoring of earthquake activity and three-component geomagnetic observations are done at King Sejong and Great Wall stations. Earth tide is monitored at Artigas Base. Continuous monitoring of GPS and gravity change are planned at King Sejong Station in the near future. Scientific research activities of each country in the area in the 1999/2000 Antarctic summer season were studied and the logistic ability of all stations was also assessed for our future international cooperation.

  11. Shape of a clamped stiff harpsichord wire driven at a resonant frequency

    Science.gov (United States)

    Hanson, Roger J.; Macomber, Hilliard Kent; Boucher, Mathew A.

    2002-05-01

    A wire transversely driven by a sinusoidal force at the resonant frequency of a vibrational mode vibrates at the driving frequency and at harmonics generated by nonlinear processes in the wire. If the amplitude of a harmonic is measured as a function of position along the wire, its shape is revealed. It differs significantly from a sinusoid in the vicinity of either end of the wire because the ends are clamped and the wire has significant stiffness. The shapes of various harmonics have been determined for a brass harpsichord wire, 70 cm long, from optical detector measurements made at different distances from a clamped end. Knowledge of shape facilitates the determination of antinode amplitudes of harmonics when the gross motion of the wire is so large that the detectors must be positioned near an end of the wire because of their very limited dynamic range. Some observations of harmonics and related phenomena were reported previously [Hanson et al., J. Acoust Soc. Am. 108, 2592 (2000); 106, 2141 (1999)]. The shape information is also needed to help separate nonlinear effects possibly occurring in the detectors from those of interest, occurring in the wire itself.

  12. Space Station services and design features for users

    Science.gov (United States)

    Kurzhals, Peter R.; Mckinney, Royce L.

    1987-01-01

    The operational design features and services planned for the NASA Space Station will furnish, in addition to novel opportunities and facilities, lower costs through interface standardization and automation and faster access by means of computer-aided integration and control processes. By furnishing a basis for large-scale space exploitation, the Space Station will possess industrial production and operational services capabilities that may be used by the private sector for commercial ventures; it could also ultimately support lunar and planetary exploration spacecraft assembly and launch facilities.

  13. Space station automation: the role of robotics and artificial intelligence (Invited Paper)

    Science.gov (United States)

    Park, W. T.; Firschein, O.

    1985-12-01

    Automation of the space station is necessary to make more effective use of the crew, to carry out repairs that are impractical or dangerous, and to monitor and control the many space station subsystems. Intelligent robotics and expert systems play a strong role in automation, and both disciplines are highly dependent on a common artificial intelligence (Al) technology base. The AI technology base provides the reasoning and planning capabilities needed in robotic tasks, such as perception of the environment and planning a path to a goal, and in expert systems tasks, such as control of subsystems and maintenance of equipment. This paper describes automation concepts for the space station, the specific robotic and expert systems required to attain this automation, and the research and development required. It also presents an evolutionary development plan that leads to fully automatic mobile robots for servicing satellites. Finally, we indicate the sequence of demonstrations and the research and development needed to confirm the automation capabilities. We emphasize that advanced robotics requires AI, and that to advance, AI needs the "real-world" problems provided by robotics.

  14. A new configuration for multilevel converters with diode clamped topology

    DEFF Research Database (Denmark)

    Nami, A.; Zare, F.; Ledwich, G.

    2008-01-01

    Due to the increased use of renewable energy and power elctronic applications, more multilevel converters (MLC) are developed. A Neutral Point Clamped (NPC) inverter is one of the most used multilevel topologies for wind turbine (WT) and photovoltaic (PV) applications. One of the most crucial...... of load changes which can avoid neutral point balancing problem in such converters. In addition, the presented topology is suitable for renewable energy systems to boost the low rectified output-voltage. In order to verify the proposed topology, steady state analysis, modelling and simulations are carried...

  15. Model Predictive Control of Z-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    2011-01-01

    This paper presents Model Predictive Control (MPC) of Z-source Neutral Point Clamped (NPC) inverter. For illustration, current control of Z-source NPC grid-connected inverter is analyzed and simulated. With MPC’s advantage of easily including system constraints, load current, impedance network...... response are obtained at the same time with a formulated Z-source NPC inverter network model. Operation steady state and transient state simulation results of MPC are going to be presented, which shows good reference tracking ability of this method. It provides new control method for Z-source NPC inverter...

  16. Solution Methods for the Periodic Petrol Station Replenishment Problem

    OpenAIRE

    C Triki

    2013-01-01

    In this paper we introduce the Periodic Petrol Station Replenishment Problem (PPSRP) over a T-day planning horizon and describe four heuristic methods for its solution. Even though all the proposed heuristics belong to the common partitioning-then-routing paradigm, they differ in assigning the stations to each day of the horizon. The resulting daily routing problems are then solved exactly until achieving optimalization. Moreover, an improvement procedure is also developed with the aim of ens...

  17. Hinkley Point 'C' power station public inquiry: outline statement of case

    International Nuclear Information System (INIS)

    1988-05-01

    This outline statement relates to the public inquiry to be held into the planning application by the Central Electricity Generating Board (CEGB) to construct a 1200 MW Pressurized Water Reactor (PWR) power station at Hinkley Point (Hinkley Point ''C'') in the United Kingdom, adjacent to an existing nuclear power station. The inquiry will consider economic, safety, environmental and planning matters relevant to the application and the implications for agriculture and local amenities of the re-aligning of two 400 kV overhead transmission lines. The outline statement contains submissions on: policy contest and approach; the requirement for Hinkley Point ''C''; design and safety; local issues. (UK)

  18. A low-voltage sense amplifier with two-stage operational amplifier clamping for flash memory

    Science.gov (United States)

    Guo, Jiarong

    2017-04-01

    A low-voltage sense amplifier with reference current generator utilizing two-stage operational amplifier clamp structure for flash memory is presented in this paper, capable of operating with minimum supply voltage at 1 V. A new reference current generation circuit composed of a reference cell and a two-stage operational amplifier clamping the drain pole of the reference cell is used to generate the reference current, which avoids the threshold limitation caused by current mirror transistor in the traditional sense amplifier. A novel reference voltage generation circuit using dummy bit-line structure without pull-down current is also adopted, which not only improves the sense window enhancing read precision but also saves power consumption. The sense amplifier was implemented in a flash realized in 90 nm flash technology. Experimental results show the access time is 14.7 ns with power supply of 1.2 V and slow corner at 125 °C. Project supported by the National Natural Science Fundation of China (No. 61376028).

  19. Development of a Space Station Operations Management System

    Science.gov (United States)

    Brandli, A. E.; McCandless, W. T.

    To enhance the productivity of operations aboard the Space Station, a means must be provided to augment, and frequently to supplant, human effort in support of mission operations and management, both on the ground and onboard. The Operations Management System (OMS), under development at the Johnson Space Center, is one such means. OMS comprises the tools and procedures to facilitate automation of station monitoring, control, and mission planning tasks. OMS mechanizes, and hence rationalizes, execution of tasks traditionally performed by mission planners, the mission control center team, onboard System Management software, and the flight crew.

  20. Development of a Space Station Operations Management System

    Science.gov (United States)

    Brandli, A. E.; Mccandless, W. T.

    1988-01-01

    To enhance the productivity of operations aboard the Space Station, a means must be provided to augment, and frequently to supplant, human effort in support of mission operations and management, both on the ground and onboard. The Operations Management System (OMS), under development at the Johnson Space Center, is one such means. OMS comprises the tools and procedures to facilitate automation of station monitoring, control, and mission planning tasks. OMS mechanizes, and hence rationalizes, execution of tasks traditionally performed by mission planners, the mission control center team, onboard System Management software, and the flight crew.

  1. Self-Oscillating Soft Switching Envelope Tracking Power Supply for Tetra2 Base Station

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2007-01-01

    This paper presents a high-efficiency, high-bandwidth solution to implementing an envelope tracking power supply for the RF power amplifier (RFPA) in a Tetra2 base station. The solution is based on synchronous rectified buck topology, augmented with high-side switch zero-current switching (ZCS......) implemented with a series inductor and an external clamping power supply. Combined with advanced power stage components (die-size MOSFETs), a high-performance fixed-frequency self-oscillating (sliding mode) control strategy and a 4th-order output filter, this leads to a compact, effective and efficient...... overall solution switching at 1MHz with 88-95% efficiency. In a class-AB RFPA amplifying a 50kHz bandwidth QAM Tetra2 signal at 4.6W average output power, the use of tracking supply voltage reduced power dissipation by 25W....

  2. Influence of the cost development in power station construction and operation on power station planning with special regard to the effects on electricity supply

    International Nuclear Information System (INIS)

    Krieb, K.H.; Frenzel, P.; Vogel, J.

    1974-01-01

    A survey on the present structure of thermal power facilities in the FRG is followed by a discussion of the development of power plant costs in the last few years. Also mentioned are the findings of studies of costs as a function of the power station size and the effects of the overall cost increase on the power generation costs of the last few years. Finally, a model conception for the development of power stations is presented which makes predictions about the future size of power stations and their constructional parts. (UA/AK) [de

  3. Contingency planning for nuclear emergencies in Hong Kong

    International Nuclear Information System (INIS)

    Wong, M. C.

    2002-01-01

    Two nuclear power stations on the coast of southern China are situated some 50 kilometers to the northeast of Hong Kong. Although the stations are far away from Hong Kong, the construction and operation of the nuclear power stations have generated public anxiety locally, in particular, after the Chernobyl accident in 1986. A comprehensive contingency plan which takes into account such concerns of the public has been implemented in Hong Kong. This plan not only aims to ensure a quick and timely response to mitigate the health impact of any accidental release but also targets to re-assure the public that the territory is not contaminated when appropriate. This paper describes the principal elements of the nuclear contingency plan in Hong Kong, namely, an extensive environmental radiation monitoring programme and a proactive public communication programme

  4. Intra-articular injection of tranexamic acid via a drain plus drain-clamping to reduce blood loss in cementless total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Mutsuzaki Hirotaka

    2012-09-01

    Full Text Available Abstract Background Patients undergoing cementless total knee arthroplasty (TKA sometimes suffer large blood loss. In a retrospective study, we explored whether postoperative intra-articular retrograde injection of tranexamic acid (TA and leaving a drain clamp in place for 1 h reduced blood loss. Patients and methods Patients (n = 140 treated with unilateral primary cementless TKA (posterior cruciate ligament retained were divided into two groups: those who had an intra-articular injection of TA (1000 mg and drain clamping for 1 h postoperatively (study group, n = 70 and those who were not given TA and did not undergo clamping of their drains (control group, n = 70. Postoperative total blood loss, volume of drainage, hemoglobin level, transfusion amounts and rates, D-dimer level at postoperative day (POD 7, and complications were recorded. Results Total blood loss, total drainage, mean transfusion volume, and transfusion rates were lower in the study group than in controls (P P P  Conclusions Immediately postoperative intra-articular retrograde injection of TA and 1 h of drain-clamping effectively reduced blood loss and blood transfusion after cementless TKA. We believe that this method is simple, easy, and suitable for these patients.

  5. Hda Monomerization by ADP Binding Promotes Replicase Clamp-mediated DnaA-ATP Hydrolysis*S⃞

    Science.gov (United States)

    Su'etsugu, Masayuki; Nakamura, Kenta; Keyamura, Kenji; Kudo, Yuka; Katayama, Tsutomu

    2008-01-01

    ATP-DnaA is the initiator of chromosomal replication in Escherichia coli, and the activity of DnaA is regulated by the regulatory inactivation of the DnaA (RIDA) system. In this system, the Hda protein promotes DnaA-ATP hydrolysis to produce inactive ADP-DnaA in a mechanism that is mediated by the DNA-loaded form of the replicase sliding clamp. In this study, we first revealed that hda translation uses an unusual initiation codon, CUG, located downstream of the annotated initiation codon. The CUG initiation codon could be used for restricting the Hda level, as this initiation codon has a low translation efficiency, and the cellular Hda level is only ∼100 molecules per cell. Hda translated using the correct reading frame was purified and found to have a high RIDA activity in vitro. Moreover, we found that Hda has a high affinity for ADP but not for other nucleotides, including ATP. ADP-Hda was active in the RIDA system in vitro and stable in a monomeric state, whereas apo-Hda formed inactive homomultimers. Both ADP-Hda and apo-Hda could form complexes with the DNA-loaded clamp; however, only ADP-Hda-DNA-clamp complexes were highly functional in the following interaction with DnaA. Formation of ADP-Hda was also observed in vivo, and mutant analysis suggested that ADP binding is crucial for cellular Hda activity. Thus, we propose that ADP is a crucial Hda ligand that promotes the activated conformation of the protein. ADP-dependent monomerization might enable the arginine finger of the Hda AAA+ domain to be accessible to ATP bound to the DnaA AAA+ domain. PMID:18977760

  6. Closed-form solution for static pull-in voltage of electrostatically actuated clamped-clamped micro/nano beams under the effect of fringing field and van der Waals force

    Science.gov (United States)

    Bhojawala, V. M.; Vakharia, D. P.

    2017-12-01

    This investigation provides an accurate prediction of static pull-in voltage for clamped-clamped micro/nano beams based on distributed model. The Euler-Bernoulli beam theory is used adapting geometric non-linearity of beam, internal (residual) stress, van der Waals force, distributed electrostatic force and fringing field effects for deriving governing differential equation. The Galerkin discretisation method is used to make reduced-order model of the governing differential equation. A regime plot is presented in the current work for determining the number of modes required in reduced-order model to obtain completely converged pull-in voltage for micro/nano beams. A closed-form relation is developed based on the relationship obtained from curve fitting of pull-in instability plots and subsequent non-linear regression for the proposed relation. The output of regression analysis provides Chi-square (χ 2) tolerance value equals to 1  ×  10-9, adjusted R-square value equals to 0.999 29 and P-value equals to zero, these statistical parameters indicate the convergence of non-linear fit, accuracy of fitted data and significance of the proposed model respectively. The closed-form equation is validated using available data of experimental and numerical results. The relative maximum error of 4.08% in comparison to several available experimental and numerical data proves the reliability of the proposed closed-form equation.

  7. Percutaneous clamping of spiral and oblique fractures of the tibial shaft: a safe and effective reduction aid during intramedullary nailing.

    Science.gov (United States)

    Collinge, Cory A; Beltran, Michael J; Dollahite, Henry A; Huber, Florian G

    2015-06-01

    The reduction of tibial shaft fractures during intramedullary nailing is important if limb alignment is to be restored and successful clinical outcomes are expected. We have used a percutaneously applied (or open) clamp or clamps to achieve and maintain reduction during nailing of all amendable tibial shaft fractures. In this article, we describe the technique and preliminary results comparing closed, simple spiral and oblique tibial shaft fractures (OTA 42-A1 and A2) managed with percutaneous clamp-assisted nailing (CAN) versus nailing using manual reduction (MRN) held by the surgical team. In the MRN group, there were an increased fracture gap (P = 0.04) and trends toward malalignment (P = 0.07) and healing time (P = 0.06) compared with the CAN group. There were also trends in clinical; no wound complications occurred in either group. We have found that percutaneous CAN of closed, simple spiral and oblique tibial shaft fractures seems safe and allows for early predictable union with reproducible alignment compared with nailing using MRN.

  8. Operations plan for the Regional Seismic Test Network

    International Nuclear Information System (INIS)

    1981-01-01

    The Regional Seismic Test Network program was established to provide a capability for detection of extremely sensitive earth movements. Seismic signals from both natural and man-made earth motions will be analyzed with the ultimate objective of accurately locating underground nuclear explosions. The Sandia National Laboratories, Albuquerque, has designed an unattended seismic station capable of recording seismic information received at the location of the seismometers installed as part of that specific station. A network of stations is required to increase the capability of determining the source of the seismic signal and the location of the source. Current plans are to establish a five-station seismic network in the United States and Canada. The Department of Energy, Nevada Operations Office, has been assigned the responsibility for deploying, installing, and operating these remote stations. This Operation Plan provides the basic information and tasking to accomplish this assignment

  9. Argentinian experience in selecting sites for nuclear power stations

    International Nuclear Information System (INIS)

    Csik, B.J.

    1975-01-01

    One nuclear power station is in operation in the Republic of Argentina, a second is under construction, and the decision to build a third has been taken. According to existing plans, about ten nuclear power stations should go into operation during the next decade. The present paper analyses the experience acquired in selecting sites for the first units, commenting on the criteria and methods applied, the studies that were carried out, the specific problems encountered and the solutions adopted, as well as on the question of acceptance of the chosen sites by the public. It goes on to describe the current programme of selection and study of sites for future nuclear power stations

  10. Pulsewidth-modulated 2-source neutral-point-clamped inverter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chang; Gao, Feng

    2007-01-01

    This paper presents the careful integration of a newly proposed Z-source topological concept to the basic neutral-point-clamped (NPC) inverter topology for designing a three-level inverter with both voltage-buck and voltage-boost capabilities. The designed Z-source NPC inverter uses two unique X......-shaped inductance-capacitance (LC) impedance networks that are connected between two isolated dc input power sources and its inverter circuitry for boosting its AC output voltage. Through the design of an appropriate pulsewidth-modulation (PWM) algorithm, the two impedance networks can be short......-circuited sequentially (without shooting through the inverter full DC link) for implementing the ldquonearest-three-vectorrdquo modulation principle with minimized harmonic distortion and device commutations per half carrier cycle while performing voltage boosting. With only a slight modification to the inverter PWM...

  11. The human dynamic clamp as a paradigm for social interaction.

    Science.gov (United States)

    Dumas, Guillaume; de Guzman, Gonzalo C; Tognoli, Emmanuelle; Kelso, J A Scott

    2014-09-02

    Social neuroscience has called for new experimental paradigms aimed toward real-time interactions. A distinctive feature of interactions is mutual information exchange: One member of a pair changes in response to the other while simultaneously producing actions that alter the other. Combining mathematical and neurophysiological methods, we introduce a paradigm called the human dynamic clamp (HDC), to directly manipulate the interaction or coupling between a human and a surrogate constructed to behave like a human. Inspired by the dynamic clamp used so productively in cellular neuroscience, the HDC allows a person to interact in real time with a virtual partner itself driven by well-established models of coordination dynamics. People coordinate hand movements with the visually observed movements of a virtual hand, the parameters of which depend on input from the subject's own movements. We demonstrate that HDC can be extended to cover a broad repertoire of human behavior, including rhythmic and discrete movements, adaptation to changes of pacing, and behavioral skill learning as specified by a virtual "teacher." We propose HDC as a general paradigm, best implemented when empirically verified theoretical or mathematical models have been developed in a particular scientific field. The HDC paradigm is powerful because it provides an opportunity to explore parameter ranges and perturbations that are not easily accessible in ordinary human interactions. The HDC not only enables to test the veracity of theoretical models, it also illuminates features that are not always apparent in real-time human social interactions and the brain correlates thereof.

  12. Multi-Unit Aspects of the Pickering Generating Station

    Energy Technology Data Exchange (ETDEWEB)

    Morison, W. G. [Atomic Energy of Canada Ltd, Sheridan Park, ON (Canada)

    1968-04-15

    The Pickering nuclear generating station is located on the north shore of Lake Ontario, about 20 miles east of the city of Toronto, Canada. The station has been planned and laid out on an eight-unit station, four units of which have now been authorized for construction. Each of these four units consists of a single heavy-water moderated and cooled CANDU-type reactor and auxiliaries coupled to a single tandem compound turbine generator with a net output of approximately 500 MW(e). The units are identical and are scheduled to come into operation at intervals of one year from 1970 to 1973. The station has been planned with central facilities for: administration maintenance laboratories, stores, change rooms, decontamination and waste management services. A common control centre, cooling water intake and discharge system, and spent fuel storage bay for four units has been arranged. A feature of the multi-unit station is a common containment system. Cost savings in building a number of identical units on the same site result from a single exclusion area, shared engineering costs, equipment purchase contracts for four identical components, and efficient use of construction plant. Operating cost savings are anticipated in the use of a common operating and maintenance staff and spare parts inventory. The plant has been arranged to minimize problems of operating, commissioning and constructing units at the same time on the same site. The layout and construction sequence have been arranged so that the first unit can be commissioned and operated with little or no interference from the construction forces working on succeeding units. During the construction phase barriers will be erected in the common control centre between operating control equipment and that being installed. Operations and construction personnel will enter the plant by separate routes and work in areas separated by physical barriers. (author)

  13. Application of Fracture Mechanics to Specify the Proof Load Factor for Clamp Band Systems of Launch Vehicles

    Science.gov (United States)

    Singaravelu, J.; Sundaresan, S.; Nageswara Rao, B.

    2013-04-01

    This article presents a methodology for evaluation of the proof load factor (PLF) for clamp band system (CBS) made of M250 Maraging steel following fracture mechanics principles.CBS is most widely used as a structural element and as a separation system. Using Taguchi's design of experiments and the response surface method (RSM) the compact tension specimens were tested to establish an empirical relation for the failure load ( P max) in terms of the ultimate strength, width, thickness, and initial crack length. The test results of P max closely matched with the developed RSM empirical relation. Crack growth rates of the maraging steel in different environments were examined. Fracture strength (σf) of center surface cracks and through-crack tension specimens are evaluated utilizing the fracture toughness ( K IC). Stress induced in merman band at flight loading conditions is evaluated to estimate the higher load factor and PLF. Statistical safety factor and reliability assessments were made for the specified flaw sizes useful in the development of fracture control plan for CBS of launch vehicles.

  14. Harmonic elimination in diode-clamped multilevel inverter using evolutionary algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Barkati, Said [Laboratoire d' analyse des Signaux et Systemes (LASS), Universite de M' sila, BP. 166, rue Ichbilia 28000 M' sila (Algeria); Baghli, Lotfi [Groupe de Recherche en Electrotechnique et Electronique de Nancy (GREEN), CNRS UMR 7030, Universite Henri Poincare Nancy 1, BP. 239, 54506 Vandoeuvre-les-Nancy (France); Berkouk, El Madjid; Boucherit, Mohamed-Seghir [Laboratoire de Commande des Processus (LCP), Ecole Nationale Polytechnique, BP. 182, 10 Avenue Hassen Badi, 16200 El Harrach, Alger (Algeria)

    2008-10-15

    This paper describes two evolutionary algorithms for the optimized harmonic stepped-waveform technique. Genetic algorithms and particle swarm optimization are applied to compute the switching angles in a three-phase seven-level inverter to produce the required fundamental voltage while, at the same time, specified harmonics are eliminated. Furthermore, these algorithms are also used to solve the starting point problem of the Newton-Raphson conventional method. This combination provides a very effective method for the harmonic elimination technique. This strategy is useful for different structures of seven-level inverters. The diode-clamped topology is considered in this study. (author)

  15. Electrothermally actuated tunable clamped-guided resonant microbeams

    Science.gov (United States)

    Alcheikh, N.; Hajjaj, A. Z.; Jaber, N.; Younis, M. I.

    2018-01-01

    We present simulation and experimental investigation demonstrating active alteration of the resonant and frequency response behavior of resonators by controlling the electrothermal actuation method on their anchors. In-plane clamped-guided arch and straight microbeams resonators are designed and fabricated with V-shaped electrothermal actuators on their anchors. These anchors not only offer various electrothermal actuation options, but also serve as various mechanical stiffness elements that affect the operating resonance frequency of the structures. We have shown that for an arch, the first mode resonance frequency can be increased up to 50% of its initial value. For a straight beam, we have shown that before buckling, the resonance frequency decreases to very low values and after buckling, it increases up to twice of its initial value. These results can be promising for the realization of different wide-range tunable microresonator. The experimental results have been compared to multi-physics finite-element simulations showing good agreement among them.

  16. Electrothermally actuated tunable clamped-guided resonant microbeams

    KAUST Repository

    Alcheikh, Nouha

    2017-06-11

    We present simulation and experimental investigation demonstrating active alteration of the resonant and frequency response behavior of resonators by controlling the electrothermal actuation method on their anchors. In-plane clamped-guided arch and straight microbeams resonators are designed and fabricated with V-shaped electrothermal actuators on their anchors. These anchors not only offer various electrothermal actuation options, but also serve as various mechanical stiffness elements that affect the operating resonance frequency of the structures. We have shown that for an arch, the first mode resonance frequency can be increased up to 50% of its initial value. For a straight beam, we have shown that before buckling, the resonance frequency decreases to very low values and after buckling, it increases up to twice of its initial value. These results can be promising for the realization of different wide–range tunable microresonator. The experimental results have been compared to multi-physics finite-element simulations showing good agreement among them.

  17. Evaluation influence of machining parameters on shape form errors in turning of machine parts clamped in the chuck with adaptive jaws

    Directory of Open Access Journals (Sweden)

    I.V. Lutsiv

    2017-12-01

    Full Text Available The paper deals with the derivation problem of the dependence of machine part geometric form deviation in cross section area on clamping diameter as well as cutting speed, feed and cutting depth in semi finish machining. The analysis of single factor circular deviation dependences on machining conditions values is performed. Using the special software application package the laboratory conditions experiment results are analyzed. The dispersion analysis including options for main linear and quadratic effects evaluation is given and the simplification model of experiment results is obtained. It presents the evaluation empiric dependence of cutting conditions and clamping diameter influence on shape error forming (dynamic error. It is found that to obtain the necessary form accuracy in machining with lathe chuck equipped with the adaptive clamping jaws it is desirable to control the most statistically significant factors that actually are the cutting depth and feed.

  18. Development and Performance of the Alaska Transportable Array Posthole Broadband Seismic Station

    Science.gov (United States)

    Aderhold, K.; Enders, M.; Miner, J.; Bierma, R. M.; Bloomquist, D.; Theis, J.; Busby, R. W.

    2017-12-01

    The final stations of the Alaska Transportable Array (ATA) will be constructed in 2017, completing the full footprint of 280 new and existing broadband seismic stations stretching across 19 degrees of latitude from western Alaska to western Canada. Through significant effort in planning, site reconnaissance, permitting and the considerable and concerted effort of field crews, the IRIS Alaska TA team is on schedule to successfully complete the construction of 194 new stations and upgrades at 28 existing stations over four field seasons. The station design and installation method was developed over the course of several years, leveraging the experience of the L48 TA deployments and existing network operators in Alaska as well as incorporating newly engineered components and procedures. A purpose-built lightweight drill was designed and fabricated to facilitate the construction of shallow boreholes to incorporate newly available posthole seismometers. This allowed for the development of a streamlined system of procedures to manufacture uniform seismic stations with minimal crew and minimal time required at each station location. A new station can typically be constructed in a single day with a four-person field crew. The ATA utilizes a hammer-drilled, cased posthole emplacement method adapted to the remote and harsh working environment of Alaska. The same emplacement design is implemented in all ground conditions to preserve uniformity across the array and eliminate the need for specialized mechanical equipment. All components for station construction are ideally suited for transport via helicopter, and can be adapted to utilize more traditional methods of transportation when available. This emplacement design delivers high quality data when embedded in bedrock or permafrost, reaching the low noise levels of benchmark permanent global broadband stations especially at long periods over 70 seconds. The TA will operate the network of real-time stations through at least

  19. NASDA knowledge-based network planning system

    Science.gov (United States)

    Yamaya, K.; Fujiwara, M.; Kosugi, S.; Yambe, M.; Ohmori, M.

    1993-01-01

    One of the SODS (space operation and data system) sub-systems, NP (network planning) was the first expert system used by NASDA (national space development agency of Japan) for tracking and control of satellite. The major responsibilities of the NP system are: first, the allocation of network and satellite control resources and, second, the generation of the network operation plan data (NOP) used in automated control of the stations and control center facilities. Up to now, the first task of network resource scheduling was done by network operators. NP system automatically generates schedules using its knowledge base, which contains information on satellite orbits, station availability, which computer is dedicated to which satellite, and how many stations must be available for a particular satellite pass or a certain time period. The NP system is introduced.

  20. Combined Triplex/Duplex Invasion of Double-Stranded DNA by "Tail-Clamp" Peptide Nucleic Acid

    DEFF Research Database (Denmark)

    Bentin, Thomas; Larsen, H. J.; Nielsen, Peter E.

    2003-01-01

    as determined by T-m measurements. Binding to double-stranded (ds) DNA occurred by combined triplex and duplex invasion as analyzed by permanganate probing. Furthermore, C-50 measurements revealed that tail-clamp PNAs consistently bound the dsDNA target more efficiently, and kinetics experiments revealed...

  1. Mobile incineration services at Commonwealth Edison's nuclear stations

    International Nuclear Information System (INIS)

    Smith, K.R.

    1985-01-01

    As the costs for low-level waste disposal escalate, and as the January 1, 1986 date draws nearer, utilities throughout the United States are formulating and implementing plans to reduce the volumes of the low-level radioactive waste being generated at their nuclear power stations. Techniques being used to accomplish this goal range from sorting of dry active waste to complete volume reduction systems, like the Aerojet VR Systems being installed at Commonwealth Edison's Byron and Braidwood Stations. In between these extremes are partial solutions to the problem, including compaction, shredding and compaction, super-compaction, resin dewatering, liquid drying, and now, mobile incineration. In June, 1983, Commonwealth Edison Company (CECO) of Chicago, Illinois, contracted Aerojet Energy Conversion Company (AECC) of Sacramento, California, to supply mobile VR services to the Dresden, La Salle, Quad Cities, and Zion Nuclear Stations. Per the contract, AECC is responsible for the design, fabrication, delivery, operation, and maintenance of a Mobile Volume Reduction System (MVRS) capable of processing combustible dry active waste and contaminated oil generated at these Com-Ed facilities. Initial commercial operation of the MVRS is planned for the Dresden Nuclear Power Station in May, 1985. This paper is intended to summarize some of the key elements resulting from the design, fabrication, and testing of the MVRS. In addition, it is intended to identify the tasks a potential user of the MVRS service must complete in order to receive permission from the Nuclear Regulatory Commission to operate the MVRS at their site

  2. Space station contamination control study: Internal combustion, phase 1

    Science.gov (United States)

    Ruggeri, Robert T.

    1987-01-01

    Contamination inside Space Station modules was studied to determine the best methods of controlling contamination. The work was conducted in five tasks that identified existing contamination control requirements, analyzed contamination levels, developed outgassing specification for materials, wrote a contamination control plan, and evaluated current materials of offgassing tests used by NASA. It is concluded that current contamination control methods can be made to function on the Space Station for up to 1000 days, but that current methods are deficient for periods longer than about 1000 days.

  3. CM Process Improvement and the International Space Station Program (ISSP)

    Science.gov (United States)

    Stephenson, Ginny

    2007-01-01

    This viewgraph presentation reviews the Configuration Management (CM) process improvements planned and undertaken for the International Space Station Program (ISSP). It reviews the 2004 findings and recommendations and the progress towards their implementation.

  4. Space Station Engineering and Technology Development. Proceedings of the Panel on Program Performance and Onboard Mission Control

    Science.gov (United States)

    1985-01-01

    An ad-hoc committee was asked to review the following questions relevant to the space station program: (1) onboard maintainability and repair; (2) in-space research and technology program and facility plans; (3) solar thermodynamic research and technology development program planning; (4) program performance (cost estimating, management, and cost avoidance); (5) onboard versus ground-based mission control; and (6) technology development road maps from IOC to the growth station. The objective of these new assignments is to provide NASA with advice on ways and means for improving the content, performance, and/or effectiveness of these elements of the space station program.

  5. Train turn restrictions and line plan performance

    DEFF Research Database (Denmark)

    Burggraeve, Sofie; Bull, Simon Henry; Lusby, Richard Martin

    In this paper we study the impact of the `turn conditions' in end stations on the performance of a line plan. If trains have to turn on their platform in an end station, the yoccupy the platform for several minutes. A more preferred option, from a timetabling point of view, would be that a train...... in a exible and large enough shunt. Starting from a given line plan, we compare two timetables, one where trains have to turn on their platform and one where trains can turn in a shunt. We evaluate the impact on the performance of the line plan by its feasibility for timetabling,the minimum overall buffer...... disappears from the platform in its end station after dwelling and only appears again when departing for a subsequent trip. In this case, the train will not interfere with other trains that dwell on the platform during the time between these events. However, this option is only possible if the train can stay...

  6. Equivalent circuit of frog atrial tissue as determined by voltage clamp-unclamp experiments.

    Science.gov (United States)

    Tarr, M; Trank, J

    1971-11-01

    The equivalent circuit that has been used in the analysis of nerve voltage-clamp data is that of the membrane capacity in parallel with the membrane resistance. Voltage-clamp experiments on frog atrial tissue indicate that this circuit will not suffice for this cardiac tissue. The change in membrane current associated with a step change in membrane potential does not show a rapid spike of capacitive current as would be expected for the simple parallel resistance-capacitance network. Rather, there is a step change in current followed by an exponential decay in current with a time constant of about 1 msec. This relatively slow capacitive charging current suggests that there is a resistance in series with the membrane capacity. A possible equivalent circuit is that of a series resistance external to the parallel resistance-capacitance network of the cell membranes. Another possible circuit assumes that the series resistance is an integral part of the cell membrane. The data presented in this paper demonstrate that the equivalent circuit of a bundle of frog atrial muscle is that of an external resistance in series with the cell membranes.

  7. Seismic stations with GSM telemetry for registration of quarry blasts

    Czech Academy of Sciences Publication Activity Database

    Brož, Milan; Číž, Radim; Málek, Jiří; Žanda, Libor

    2000-01-01

    Roč. 2000, 16 (118) (2000), s. 25-32 ISSN 1211-1910 Institutional research plan: CEZ:AV0Z3046908 Keywords : blasting * seismic station * GSM mobile modem Subject RIV: DC - Siesmology, Volcanology, Earth Structure

  8. How the Station will operate. [operation, management, and maintenance in space

    Science.gov (United States)

    Cox, John T.

    1988-01-01

    Aspects of the upcoming operational phase of the Space Station (SS) are examined. What the crew members will do with their time in their specialized roles is addressed. SS maintenance and servicing and the interaction of the SS Control Center with Johnson Space Center is discussed. The planning of payload operations and strategic planning for the SS are examined.

  9. PWM Regulation of Grid-Tied PV System on the Base of Photovoltaic-Fed Diode-Clamped Inverters

    Directory of Open Access Journals (Sweden)

    Oleschuk V.I.

    2015-12-01

    Full Text Available Investigation of grid-tied photovoltaic system on the base of two diode-clamped inverters, controlled by specific algorithms of pulse-width modulation (PWM, has been done. This system includes two strings of photovoltaic panels feeding two diode-clamped inverters. The outputs of inverters are connected with the corresponding windings on the primary side of three-phase transformer, connected with a grid. In order to reduce phase voltage distortion and to increase efficiency of operation of the system, special scheme of control and modulation of inverters has been used, providing minimization of common-mode voltages and voltage waveforms symmetries under different operating conditions. Detailed simulation of processes in this photovoltaic-fed power conversion system has been executed. The results of simulations verify good performance of photovoltaic system regulated in accordance with specific strategy of control and modulation.

  10. The Circuit-Level Decoupling Modulation Strategy for Three-Level Neutral-Point-Clamped (TL-NPC) Inverter

    DEFF Research Database (Denmark)

    Zhang, Zhe; Thomsen, Ole Cornelius; Andersen, Michael A. E.

    2011-01-01

    In this paper, a circuit-level decoupling modulation strategy is proposed for the three-level (TL) neutral-point-clamped (NPC) inverters. With the proposed modulation scheme, the TL-NPC inverter can be decoupled into two three-level Buck converters in each defined operating section, which makes...

  11. Higher order modes excitation of electrostatically actuated clamped–clamped microbeams: experimental and analytical investigation

    KAUST Repository

    Jaber, Nizar

    2016-01-06

    © 2016 IOP Publishing Ltd. In this study, we demonstrate analytically and experimentally the excitations of the higher order modes of vibrations in electrostatically actuated clamped-clamped microbeam resonators. The concept is based on using partial electrodes with shapes that induce strong excitation of the mode of interest. The devices are fabricated using polyimide as a structural layer coated with nickel from the top and chrome and gold layers from the bottom. Experimentally, frequency sweeps with different electro-dynamical loading conditions are shown to demonstrate the excitation of the higher order modes of vibration. Using a half electrode, the second mode is excited with high amplitude of vibration compared with almost zero response using the full electrode. Also, using a two-third electrode configuration is shown to amplify the third mode resonance amplitude compared with the full electrode under the same electrical loading conditions. An analytical model is developed based on the Euler-Bernollui beam model and the Galerkin method to simulate the device response. Good agreement between the simulation results and the experimental data is reported.

  12. A direct proofreader-clamp interaction stabilizes the Pol III replicase in the polymerization mode

    KAUST Repository

    Jergic, Slobodan; Horan, Nicholas P.; Elshenawy, Mohamed; Mason, Claire E.; Urathamakul, Thitima; Ozawa, Kiyoshi; Robinson, Andrew J.; Goudsmits, Joris M H; Wang, Yao; Pan, Xuefeng; Beck, Jennifer L.; Van Oijen, Antoine M.; Huber, Thomas L.; Hamdan, Samir; Dixon, Nicholas E.

    2013-01-01

    Processive DNA synthesis by the αÉ"θ core of the Escherichia coli Pol III replicase requires it to be bound to the β 2 clamp via a site in the α polymerase subunit. How the É" proofreading exonuclease subunit influences DNA synthesis by α was not previously understood. In this work, bulk assays of DNA replication were used to uncover a non-proofreading activity of É". Combination of mutagenesis with biophysical studies and single-molecule leading-strand replication assays traced this activity to a novel β-binding site in É" that, in conjunction with the site in α, maintains a closed state of the αÉ"θ-β 2 replicase in the polymerization mode of DNA synthesis. The É"-β interaction, selected during evolution to be weak and thus suited for transient disruption to enable access of alternate polymerases and other clamp binding proteins, therefore makes an important contribution to the network of protein-protein interactions that finely tune stability of the replicase on the DNA template in its various conformational states. © 2013 European Molecular Biology Organization.

  13. A direct proofreader-clamp interaction stabilizes the Pol III replicase in the polymerization mode

    KAUST Repository

    Jergic, Slobodan

    2013-02-22

    Processive DNA synthesis by the αÉ"θ core of the Escherichia coli Pol III replicase requires it to be bound to the β 2 clamp via a site in the α polymerase subunit. How the É" proofreading exonuclease subunit influences DNA synthesis by α was not previously understood. In this work, bulk assays of DNA replication were used to uncover a non-proofreading activity of É". Combination of mutagenesis with biophysical studies and single-molecule leading-strand replication assays traced this activity to a novel β-binding site in É" that, in conjunction with the site in α, maintains a closed state of the αÉ"θ-β 2 replicase in the polymerization mode of DNA synthesis. The É"-β interaction, selected during evolution to be weak and thus suited for transient disruption to enable access of alternate polymerases and other clamp binding proteins, therefore makes an important contribution to the network of protein-protein interactions that finely tune stability of the replicase on the DNA template in its various conformational states. © 2013 European Molecular Biology Organization.

  14. High Performance ZVT with Bus Clamping Modulation Technique for Single Phase Full Bridge Inverters

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Yinglai; Ayyanar, Raja

    2016-03-20

    This paper proposes a topology based on bus clamping modulation and zero-voltage-transition (ZVT) technique to realize zero-voltage-switching (ZVS) for all the main switches of the full bridge inverters, and inherent ZVS and/or ZCS for the auxiliary switches. The advantages of the strategy include significant reduction in the turn-on loss of the ZVT auxiliary switches which typically account for a major part of the total loss in other ZVT circuits, and reduction in the voltage ratings of auxiliary switches. The modulation scheme and the commutation stages are analyzed in detail. Finally, a 1kW, 500 kHz switching frequency inverter of the proposed topology using SiC MOSFETs has been built to validate the theoretical analysis. The ZVT with bus clamping modulation technique of fixed timing and adaptive timing schemes are implemented in DSP TMS320F28335 resulting in full ZVS for the main switches in the full bridge inverter. The proposed scheme can save up to 33 % of the switching loss compared with no ZVT case.

  15. Railway Station Built In The Interwar Period In Telšiai

    Directory of Open Access Journals (Sweden)

    Iveta Dabašinskienė

    2014-05-01

    Full Text Available Abstract The most important and biggest railway station in Telšiai as a part of one of the first railroads Kretinga – Telšiai – Kužiai built in the interwar period is examined in this article. A variety of elements of the station’s infrastructure with special attention to passenger stations, houses for railway workers and warehouses (pakhauze are revealed in the article. The significance of Lietūkis warehouses founded in the territory of the station and their connections with the railroad are discussed. Moreover, the arrangement of Telšiai Station buildings in the territory are analyzed and compared to the preserved site plan of the station and photo of the situation dated back to the Second World War taken by Germans from the air. While comparing the available sources, urban developments of the station area are discussed. The analysis material is based on archival sources, the interwar documentary publications and research of the location.

  16. Definition of technology development missions for early space station satellite servicing, volume 1

    Science.gov (United States)

    1983-01-01

    The testbed role of an early manned space station in the context of a satellite servicing evolutionary development and flight demonstration technology plan which results in a satellite servicing operational capability is defined. A satellite servicing technology development mission (a set of missions) to be performed on an early manned space station is conceptually defined.

  17. Remerschen nuclear power station with BBR pressurized water reactor

    International Nuclear Information System (INIS)

    Hoffmann, J.P.

    1975-01-01

    On the basis of many decades of successful cooperation in the electricity supply sector with the German RWE utility, the Grand Duchy of Luxemburg and RWE jointly founded Societe Luxembourgeoise d'Energie Nucleaire S.A. (SENU) in 1974 in which each of the partners holds a fifty percent interest. SENU is responsible for planning, building and operating this nuclear power station. Following an international invitation for bids on the delivery and turnkey construction of a nuclear power station, the consortium of the German companies of Brown, Boveri and Cie. AG (BBC), Babcock - Brown Boveri Reaktor GmbH (BBR) and Hochtief AG (HT) received a letter of intent for the purchase of a 1,300 MW nuclear power station equipped with a pressurized water reactor. The 1,300 MW station of Remerschen will be largely identical with the Muelheim-Kaerlich plant under construction by the same consortium near Coblence on the River Rhine since early 1975. According to present scheduling, the Remerschen nuclear power station could start operation in 1981. (orig.) [de

  18. Solar-Assisted Electric Vehicle Charging Station Interim Report

    Energy Technology Data Exchange (ETDEWEB)

    Lapsa, Melissa Voss [ORNL; Durfee, Norman [ORNL; Maxey, L Curt [ORNL; Overbey, Randall M [ORNL

    2011-09-01

    Oak Ridge National Laboratory (ORNL) has been awarded $6.8 million in the Department of Energy (DOE) American Recovery and Reinvestment Act (ARRA) funds as part of an overall $114.8 million ECOtality grant with matching funds from regional partners to install 125 solar-assisted Electric Vehicle (EV) charging stations across Knoxville, Nashville, Chattanooga, and Memphis. Significant progress has been made toward completing the scope with the installation of 25 solar-assisted charging stations at ORNL; six stations at Electric Power Research Institute (EPRI); and 27 stations at Nissan's Smyrna and Franklin sites, with three more stations under construction at Nissan's new lithium-ion battery plant. Additionally, the procurement process for contracting the installation of 34 stations at Knoxville, the University of Tennessee Knoxville (UTK), and Nashville sites is underway with completion of installation scheduled for early 2012. Progress is also being made on finalizing sites and beginning installations of 30 stations in Nashville, Chattanooga, and Memphis by EPRI and Tennessee Valley Authority (TVA). The solar-assisted EV charging station project has made great strides in fiscal year 2011. A total of 58 solar-assisted EV parking spaces have been commissioned in East and Middle Tennessee, and progress on installing the remaining 67 spaces is well underway. The contract for the 34 stations planned for Knoxville, UTK, and Nashville should be underway in October with completion scheduled for the end of March 2012; the remaining three Nissan stations are under construction and scheduled to be complete in November; and the EPRI/TVA stations for Chattanooga, Vanderbilt, and Memphis are underway and should be complete by the end of March 2012. As additional Nissan LEAFs are being delivered, usage of the charging stations has increased substantially. The project is on course to complete all 125 solar-assisted EV charging stations in time to collect meaningful data

  19. TH-EF-BRB-06: Implementation of a Modulated-Arc Total Body Irradiation (TBI) Technique Using the RayStation Treatment Planning System

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, J; Cheung, J; Held, M; Han, D; Morin, O [UCSF, San Francisco, CA (United States)

    2016-06-15

    Purpose: To develop a clinical workflow for delivering a modulated-arc total body irradiation (TBI) with RayStation scripting. This technique uses arc fields with the patient lying at floor level on a padded table and is validated through measurements taken on a custom-made TBI phantom. Methods: Treatment planning was performed for a retrospective cohort of eight patients with a diverse range of heights and body types. Each was replanned using an open-field dual arc method, with the patient in supine and prone positions on the floor of the vault. All plans were optimized using Raystation Planning 4.7.2.5 (RaySearch Laboratories, Stockholm, Sweden), with 200 cGy prescribed to the 95% of the body contour − 5mm. This results in an open-field beam that sweeps craniocaudally across the length of the patient. The technique is validated with measurements at 10 cm intervals in a custom-milled, 5 cm thick acrylic phantom. A centrally located CC13 ion chamber and a Mobile MOSFET (Best Medical Canada, Ottawa, ON) detector array were used to measure dose. Supine and prone arcs for each patient were consecutively delivered, and the aggregate dose at each point was compared to the planned dose calculated in the phantom. Results: The ion chamber measurements differed from the planned dose by an average of .5%, with a standard deviation of 2.1%. All measured data for the MOSFETS were within 10% of the corresponding planned dose except for two outlying points. The standard deviation of dose differences across the entire cohort was 4.0%. Most significant discrepancies occurred either in inhomogeneous regions with large gradients, or at inferior points where beam angle was steepest. Conclusion: We have confirmed that the planned dose is well matched to our measurements within 10% for this method of planning and delivery. We are currently incorporating this technique into our clinical workflow. This work is supported by RaySearch.

  20. Symbol-stream Combiner: Description and Demonstration Plans

    Science.gov (United States)

    Hurd, W. J.; Reder, L. J.; Russell, M. D.

    1984-01-01

    A system is described and demonstration plans presented for antenna arraying by symbol stream combining. This system is used to enhance the signal-to-noise ratio of a spacecraft signals by combining the detected symbol streams from two or more receiving stations. Symbol stream combining has both cost and performance advantages over other arraying methods. Demonstrations are planned on Voyager 2 both prior to and during Uranus encounter. Operational use is possible for interagency arraying of non-Deep Space Network stations at Neptune encounter.

  1. Probabilistic Harmonic Calculation in Distribution Networks with Electric Vehicle Charging Stations

    Directory of Open Access Journals (Sweden)

    Jianxue Wang

    2014-01-01

    Full Text Available Integrating EV charging station into power grid will bring impacts on power system, among which the most significant one is the harmonic pollution on distribution networks. Due to the uncertainty of the EV charging process, the harmonic currents brought by EV charging stations have a random nature. This paper proposed a mathematical simulation method for studying the working status of charging stations, which considers influencing factors including random leaving factor, electricity price, and waiting time. Based on the proposed simulation method, the probability distribution of the harmonic currents of EV charging stations is obtained and used in the calculation of the probability harmonic power flow. Then the impacts of EVs and EV charging stations on distribution networks can be analyzed. In the case study, the proposed simulation and analysis method is implemented on the IEEE-34 distribution network. The influences of EV arrival rates, the penetration rate, and the accessing location of EV charging station are also investigated. Results show that this research has good potential in guiding the planning and construction of charging station.

  2. Loss of European silver eel passing a hydropower station

    DEFF Research Database (Denmark)

    Pedersen, Michael Ingemann; Jepsen, Niels; Aarestrup, Kim

    2012-01-01

    The aim of this study was to assess escapement success of silver eels, Anguilla anguilla (L.), in a lowland river while passing a reservoir and a hydropower station. It was hypothesized that passage success would be lowest at the hydropower station and that survival and migration speed would...... that within the study period, only 23% of the tagged eels reached the tidal limit, mainly due to difficulties in passing the hydropower dam. With such high loss-rates, the escapement goals set in the management plan cannot be achieved...

  3. Measuring Transit Oriented Development of Existing Urban Areas around Metro Stations in Faridabad City

    Directory of Open Access Journals (Sweden)

    Sat Pal

    2018-01-01

    Full Text Available Urban population in Indian cities is encouraging auto reliance and having unsafe economic, social and environmental consequences. Land-use-change patterns are the outcome of the complex relations between the human and the physical surroundings. To address these issues the planners are moving beyond land use planning to a sustainable development. Transit and Land use planning are important components to achieve sustainable future of urban development. TOD is a planning tool to encourage this integration. This paper discusses the land use scenario and opportunity around four Metro transit stations in Faridabad city. Different methods and various sets of indicators are considered to evaluate and measure TOD index in this study. This study will evaluate and measure the Faridabad city in the context of land use around Metro Stations to support TOD. This paper seeks to answer how to promote walkable communities, compact and transit-oriented development (TOD that incorporates mixed land use development, including neighbourhood schools, retail and business related space and a mix range of housing types within walkable distance. This paper concludes that the stations area which had a low TOD score needs to have policy for improvement. If planned efficiently, TODs can realize the sustainable development with considerable change in the urban development that focuses on pedestrian based neighbourhood planning.

  4. Accelerating Rf Station For Hirfl-csr, Lanzhou, China

    CERN Document Server

    Arbuzov, V S; Dranichnikov, A N; Gorniker, E I; Kondakov, A A; Kondaurov, M; Kruchkov, Ya G; Krutikhin, S A; Kurkin, G Ya; Mironenko, L A; Motygin, S V; Osipov, V N; Petrov, V M; Pilan, Andrey M; Popov, A M; Sedlyarov, I K; Selivanov, A N; Shteinke, A R; Vajenin, N F

    2004-01-01

    In accordance with the plan of cooperation with the Institute of Modern Physics (IMP), Lanzhou, China, the Budker Institute of Nuclear Physics (BINP), Novosibirsk, Russia has produced and supplied an accelerating RF station for the multipurpose Cooling Storage Ring system (CSR), which is being constructed at IMP. The RF station had been tested at IMP site and now is installed into the Main Ring of the facilities. The RF station operates in the frequency range of 0.25~1.7 MHz. Maximum accelerating voltage is 8 kV. The resonance frequency of the RF cavity is tuned in the whole frequency range by biasing of ferrites, which are used in the cavity. Ferrites of 600NN type were produced by a firm manufacture "Magneton", St. Petersburg. The pressure in the cavity vacuum chamber is lower, than 3·10-11

  5. Physiologic Responses to Infrarenal Aortic Cross-Clamping during Laparoscopic or Conventional Vascular Surgery in Experimental Animal Model: Comparative Study

    Directory of Open Access Journals (Sweden)

    María F. Martín-Cancho

    2008-01-01

    Full Text Available The aim of this study was to compare the hemodynamic and ventilatory effects of prolonged infrarenal aortic cross-clamping in pigs undergoing either laparotomy or laparoscopy. 18 pigs were used for this study. Infrarenal aortic crossclamping was performed for 60 minutes in groups I (laparotomy, n=6 and II (laparoscopy, n=6. Group III (laparoscopy, n=6 underwent a 120-minute long pneumoperitoneum in absence of aortic clamping (sham group. Ventilatory and hemodynamic parameters and renal function were serially determined in all groups. A significant decrease in pH and significant increase in PaCO2 were observed in group II, whereas no changes in these parameters were seen in group I and III. All variables returned to values similar to baseline in groups I and II 60 minutes after declamping. A significant increase in renal resistive index was evidenced during laparoscopy, with significantly higher values seen in Group II. Thus a synergic effect of pneumoperitoneum and aortic cross-clamping was seen in this study. These two factors together cause decreased renal perfusion and acidosis, thus negatively affecting the patient's general state during this type of surgery.

  6. Multi-mode excitation of a clamped–clamped microbeam resonator

    KAUST Repository

    Younis, Mohammad I.

    2015-02-18

    We present modeling and simulation of the nonlinear dynamics of a microresonator subjected to two-source electrostatic excitation. The resonator is composed of a clamped–clamped beam excited by a DC voltage load superimposed to two AC voltage loads of different frequencies. One frequency is tuned close to the first natural frequency of the beam and the other is close to the third (second symmetric) natural frequency. A multi-mode Galerkin procedure is applied to extract a reduced-order model, which forms the basis of the numerical simulations. Time history response, Poincare’ sections, Fast Fourier Transforms FFT, and bifurcation diagrams are used to reveal the dynamics of the system. The results indicate complex nonlinear phenomena, which include quasiperiodic motion, torus bifurcations, and modulated chaotic attractors.

  7. Enhanced Buck-Boost Three-Level Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Tan, K. K.; Gao, F.; Chiang Loh, Poh

    2009-01-01

    In traditional three-level neutral-point-clamped (NPC) inverters, a major issue is capacitor voltage imbalance, which results in low order harmonics. The compensation of the capacitor voltages often require additional control complexity, which cannot be conveniently implemented. The "alternative...... phase opposition disposition" (APOD) modulation method used in traditional NPC topologies also has lower harmonics performance as compared to the "phase disposition" (PD) modulation method.In this paper, we introduce a new three-level NPC topology that utilises the harmonically superior PD modulation...... method, with the ability to easily adjust for capacitor voltage imbalances. To further improve the boost capability of the three-level NPC inverters, another new topology introduces 2 additional diodes,achieving higher boost performance while totally eliminating thepossibility of capacitor voltage...

  8. Measuring Robustness of Timetables at Stations using a Probability Distribution

    DEFF Research Database (Denmark)

    Jensen, Lars Wittrup; Landex, Alex

    Stations are often the limiting capacity factor in a railway network. This induces interdependencies, especially at at-grade junctions, causing network effects. This paper presents three traditional methods that can be used to measure the complexity of a station, indicating the robustness...... of the station’s infrastructure layout and plan of operation. However, these three methods do not take the timetable at the station into consideration. Therefore, two methods are introduced in this paper, making it possible to estimate the robustness of different timetables at a station or different...... infrastructure layouts given a timetable. These two methods provide different precision at the expense of a more complex calculation process. The advanced and more precise method is based on a probability distribution that can describe the expected delay between two trains as a function of the buffer time...

  9. Surface analysis of anodized aluminum clamps from NASA-LDEF satellite

    Science.gov (United States)

    Grammer, H. L.; Wightman, J. P.; Young, Philip R.

    1992-01-01

    Surface analysis results of selected anodized aluminum clamps containing black (Z306) and white (A276) paints which received nearly six years of Low Earth Orbit (LEO) exposure on the Long Duration Exposure Facility are reported. Surface analytical techniques, including x-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), and scanning electron microscopy/energy dispersive analysis by x-ray (SEM/EDAX), showed significant differences in the surface composition of these materials depending upon the position on the LDEF. Differences in the surface composition are attributed to varying amounts of atomic oxygen and vacuum ultraviolet radiation (VUV). Silicon containing compounds were the primary contaminant detected on the materials.

  10. Acquisition of wood fuel at the Joseph C. McNeil Generating Station

    Energy Technology Data Exchange (ETDEWEB)

    Kropelin, W. [Burlington Electric Dept., VT (United States)

    1993-12-31

    The Joseph C. McNeil Generating Station is the world`s largest single boiler, municipally-owned, wood-fired electrical generating plant. The 50 megawatt McNeil Station is located in Burlington, Vermont and is owned by several Vermont public and private electric utilities. The operator and majority owner is the City of Burlington Electric Department (BED). Wood fuel procurement for the McNeil Station has been conducted in an environmentally sensitive way. Harvesting is carried out in conformance with a comprehensive wood chip harvesting policy and monitored by professional foresters. Unpredictable levels of Station operation require rigid adherence to a wood storage plan that minimizes the risk of over heating and spontaneous combustion of stockpiled fuel.

  11. Occupational radiation exposures at Canadian CANDU nuclear power stations

    International Nuclear Information System (INIS)

    LeSurf, J.E.; Taylor, G.F.

    1982-09-01

    In Canada, methods to reduce the radiation exposure to workers at nuclear power reactors have been studied and implemented since the early days of the CANDU reactor program. Close collaboration between the designers, the operators, and the manufacturers has reduced the total exposure at each station, the dose requirement to operate and maintain each successive station compared with earlier stations, and the average annual exposure per worker. Specific methods developed to achieve dose reduction include water chemistry; corrosion resistant materials; low cobalt materials; decontamination; hot filtration, improved equipment reliability, maintainability, and accessibility; improved shielding design and location; planning of work for low exposure; improved operating and maintenance procedures; removal of tritium from D 2 O systems and work environments; improved protective clothing; on-power refuelling; worker awareness and training; and many other small improvements. The 1981 occupational dose productivity factors for Pickering A and Bruce A nuclear generating stations were respectively 0.43 and 0.2 rem/MW(e).a

  12. Glucose consumption by various tissues in pregnant rats : effects of a 6-day euglycaemic hyperinsulinaemic clamp

    NARCIS (Netherlands)

    Nieuwenhuizen, AG; Schuiling, GA; Bonen, A; Paans, AMJ; Vaalburg, W; Koiter, TR

    In the course of pregnancy maternal tissues become increasingly more insensitive to insulin. As 6 days of euglycaemic hyperinsulinaemic clamping, from day 8 until 14 of gestation, ameliorates total glucose consumption, we analysed the contribution of individual tissues in this phenomenon. We

  13. Manned space stations - A perspective

    Science.gov (United States)

    Disher, J. H.

    1981-09-01

    The findings from the Skylab missions are discussed as they relate to the operations planning of future space stations such as Spacelab and the proposed Space Operations Center. Following a brief description of the Skylab spacecraft, the significance of the mission as a demonstration of the possibility of effecting emergency repairs in space is pointed out. Specific recommendations made by Skylab personnel concerning capabilities for future in-flight maintenance are presented relating to the areas of spacecraft design criteria, tool selection and spares carried. Attention is then given to relevant physiological findings, and to habitability considerations in the areas of sleep arrangements, hygiene, waste management, clothing, and food. The issue of contamination control is examined in detail as a potential major system to be integrated into future design criteria. The importance of the Skylab results to the designers of future space stations is emphasized.

  14. Training of power station staff

    International Nuclear Information System (INIS)

    Dusserre, J.

    1993-01-01

    ELECTRICITE DE FRANCE currently operates 51 generating stations with 900 and 1300 MW Pressurized Water Reactors while, only 15 years ago, France possessed only a very small number of such stations. It was therefore vital to set up a major training organization to produce staff capable of starting, controlling and maintaining these facilities with a constant eye to improving quality and safety. Operator and maintenance staff training is based on highly-structured training plans designed to match both the post to be filled and the qualifications possessed by the person who is to fill it. It was essential to set up suitable high-performance training resources to handle this fast growth in staff. These resources are constantly being developed and allow EDF to make steady progress in a large number of areas, varying from the effects of human factors to the procedures to be followed during an accident

  15. Commerical electric power cost studies. Capital cost addendum multi-unit coal and nuclear stations

    International Nuclear Information System (INIS)

    1977-09-01

    This report is the culmination of a study performed to develop designs and associated capital cost estimates for multi-unit nuclear and coal commercial electric power stations, and to determine the distribution of these costs among the individual units. This report addresses six different types of 2400 MWe (nominal) multi-unit stations as follows: Two Unit PWR Station-1139 MWe Each, Two Unit BWR Station-1190 MWe Each, Two Unit High Sulfur Coal-Fired Station-1232 MWe Each, Two Unit Low Sulfur Coal-Fired Station-1243 MWe Each, Three Unit High Sulfur Coal-Fired Station-794 MWe Each, Three Unit Low Sulfur Coal-Fired Station-801 MWe Each. Recent capital cost studies performed for ERDA/NRC of single unit nuclear and coal stations are used as the basis for developing the designs and costs of the multi-unit stations. This report includes the major study groundrules, a summary of single and multi-unit stations total base cost estimates, details of cost estimates at the three digit account level and plot plan drawings for each multi-unit station identified

  16. A self-strain feedback tuning-fork-shaped ionic polymer metal composite clamping actuator with soft matter elasticity-detecting capability for biomedical applications.

    Science.gov (United States)

    Feng, Guo-Hua; Huang, Wei-Lun

    2014-12-01

    This paper presents a smart tuning-fork-shaped ionic polymer metal composite (IPMC) clamping actuator for biomedical applications. The two fingers of the actuator, which perform the clamping motion, can be electrically controlled through a unique electrode design on the IPMC material. The generated displacement or strain of the fingers can be sensed using an integrated soft strain-gage sensor. The IPMC actuator and associated soft strain gage were fabricated using a micromachining technique. A 13.5×4×2 mm(3) actuator was shaped from Nafion solution and a selectively grown metal electrode formed the active region. The strain gage consisted of patterned copper foil and polyethylene as a substrate. The relationship between the strain gage voltage output and the displacement at the front end of the actuator's fingers was characterized. The equivalent Young's modulus, 13.65 MPa, of the soft-strain-gage-integrated IPMC finger was analyzed. The produced clamping force exhibited a linear increasing rate of 1.07 mN/s, based on a dc driving voltage of 7 V. Using the developed actuator to clamp soft matter and simultaneously acquire its Young's modulus was achieved. This demonstrated the feasibility of the palpation function and the potential use of the actuator in minimally invasive surgery. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, Michael A.E.

    2005-07-01

    This paper discusses the advantages and problems when implementing direct energy conversion switching-mode audio power amplifiers. It is shown that the total integration of the power supply and Class D audio power amplifier into one compact direct converter can simplify design, increase efficiency and integration level, reduce product volume and lower its cost. As an example, the principle of operation and the measurements made on a direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp are presented. (au)

  18. Direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper discusses the advantages and problems when implementing direct energy conversion switching-mode audio power amplifiers. It is shown that the total integration of the power supply and Class D audio power amplifier into one compact direct converter can simplify the design, increase...... efficiency, reduce the product volume and lower its cost. As an example, the principle of operation and the measurements made on a direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp are presented....

  19. Double-Station Automatic Video Observation of the Meteors

    Czech Academy of Sciences Publication Activity Database

    Vítek, S.; Koten, Pavel; Páta, P.; Fliegel, K.

    2010-01-01

    Roč. 2010, - (2010), 943145/1-943145/4 ISSN 1687-7969 R&D Projects: GA ČR GA205/09/1302 Grant - others:GA ČR(CZ) GA102/09/0997 Institutional research plan: CEZ:AV0Z10030501 Keywords : double station observation * video technique Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  20. Hinkley Point 'C' power station public enquiry: proof of evidence on coal fired power station sites

    Energy Technology Data Exchange (ETDEWEB)

    Fothergill, S.; Witt, S.

    1988-11-01

    The Coalfield Communities Campaign (CCC) has argued that if a new base-load power station is required it should be coal-fired rather than nuclear, and that it should use UK coal. Proposals for new power stations at both Hinkley Point and at Fawley have encountered very considerable local and regional opposition, and this is increasingly likely to be the case at many other sites especially in Southern England. In contrast the CCC has sought to demonstrate that its member authorities would generally welcome the development of new coal-fired capacity on appropriate sites within their areas. In particular, this proof establishes that there is a prima facie case for considering three sites - Thorpe Marsh, Hams Hall and Uskmouth - as potential locations for a new large coal-fired power station as an alternative to Hinkley Point C. The relevant local authorities have expressed their willingness to co-operate in more detailed planning or technical investigations to secure a coal-fired power station on these sites. The CCC considers this to be a major and unprecedented offer to the CEGB and its successor bodies, which could greatly speed the development of new power staion capacity and be of considerable economic and social benefit to coalfield communities.

  1. International Space Station (ISS) Plasma Contactor Unit (PCU) Utilization Plan Assessment Update

    Science.gov (United States)

    Hernandez-Pellerano, Amri; Iannello, Christopher J.; Garrett, Henry B.; Ging, Andrew T.; Katz, Ira; Keith, R. Lloyd; Minow, Joseph I.; Willis, Emily M.; Schneider, Todd A.; Whittlesey, Edward J.; hide

    2014-01-01

    The International Space Station (ISS) vehicle undergoes spacecraft charging as it interacts with Earth's ionosphere and magnetic field. The interaction can result in a large potential difference developing between the ISS metal chassis and the local ionosphere plasma environment. If an astronaut conducting extravehicular activities (EVA) is exposed to the potential difference, then a possible electrical shock hazard arises. The control of this hazard was addressed by a number of documents within the ISS Program (ISSP) including Catastrophic Safety Hazard for Astronauts on EVA (ISS-EVA-312-4A_revE). The safety hazard identified the risk for an astronaut to experience an electrical shock in the event an arc was generated on an extravehicular mobility unit (EMU) surface. A catastrophic safety hazard, by the ISS requirements, necessitates mitigation by a two-fault tolerant system of hazard controls. Traditionally, the plasma contactor units (PCUs) on the ISS have been used to limit the charging and serve as a "ground strap" between the ISS structure and the surrounding ionospheric plasma. In 2009, a previous NASA Engineering and Safety Center (NESC) team evaluated the PCU utilization plan (NESC Request #07-054-E) with the objective to assess whether leaving PCUs off during non-EVA time periods presented risk to the ISS through assembly completion. For this study, in situ measurements of ISS charging, covering the installation of three of the four photovoltaic arrays, and laboratory testing results provided key data to underpin the assessment. The conclusion stated, "there appears to be no significant risk of damage to critical equipment nor excessive ISS thermal coating damage as a result of eliminating PCU operations during non- EVA times." In 2013, the ISSP was presented with recommendations from Boeing Space Environments for the "Conditional" Marginalization of Plasma Hazard. These recommendations include a plan that would keep the PCUs off during EVAs when the

  2. Reducing lighting electricity use in underground metro stations

    International Nuclear Information System (INIS)

    Casals, Miquel; Gangolells, Marta; Forcada, Núria; Macarulla, Marcel

    2016-01-01

    Highlights: • Lighting systems are big energy consumers in underground metro stations. • An adaptive lighting system strategy is developed for underground stations. • Dimming controls are based on station occupancy levels and maintenance cycles. • The k-means clustering technique is used to identify stations’ occupancy patterns. • Savings were found to amount to 255.47 MW h in 2 years for a case study metro network. - Abstract: Lighting systems are usually one of the largest electrical end-uses in underground metro stations. Taking into account that budget restrictions in publicly owned companies hinder energy efficiency retrofit projects that require high initial investments, affordable energy saving strategies are needed. This paper presents a low-cost approach for reducing lighting electricity use in underground stations, without affecting passengers’ comfort or the metro operator’s service. For this purpose, an adaptive lighting strategy of dimming the illuminance levels of artificial light sources has been developed. Dimming controls are based on the occupancy of the station, and the preventive maintenance and cleaning cycles of the luminaires. The stations’ monthly occupancy patterns are defined through the k-means clustering technique. To illustrate its effectiveness, the method was applied to 115 underground stations of the Barcelona metro network. The results revealed overall electricity savings of 255.47 MW h on a biannual basis, which represents 36.22% of the stations’ baseline lighting consumption. Individual energy savings were found to range from 25 to 87.5 MW h/year in the stations of the Barcelona metro network, depending on the number and profile of station users. The research findings will undoubtedly be useful for the future energy efficiency project plans of worldwide metro operators and managers of other underground spaces.

  3. Socio-economic impacts of nuclear generating stations: summary report on the NRC post-licensing studies

    International Nuclear Information System (INIS)

    Chalmers, J.; Pijawka, D.; Branch, K.; Bergmann, P.; Flynn, J.; Flynn, C.

    1982-07-01

    Information is presented concerning the conceptual framework for the assessment of socioeconomic impacts; methodology for the post-licensing case studies; socioeconomic changes due to the construction and operation of nuclear generating stations; public response to the construction and operation of nuclear generating stations; socioeconomic consequences of the accident at Three Mile Island; the significance of socioeconomic change due to the construction and operation of nuclear generating stations; findings of the post-licensing studies relative to the nuclear station impact literature; and implications of the findings for projective assessments and planning studies

  4. Place-making around high-speed railway stations in China

    NARCIS (Netherlands)

    Dai, G.

    2015-01-01

    The rapid expansion of the High-Speed Railway (HSR) network in China generates leapfrog urbanization on the urban periphery in the forms of ambitious blueprint plan around the mega hubs. Nevertheless, most of the station areas and spatial extension lack "place quality". The place-making process of

  5. Effects of mixing technologies on continuous methyl ester production: Comparison of using plug flow, static mixer, and ultrasound clamp

    International Nuclear Information System (INIS)

    Somnuk, Krit; Prasit, Tanongsak; Prateepchaikul, Gumpon

    2017-01-01

    Highlights: • Four types of continuous reactors were compared with methyl ester conversion. • Plug flow, static mixer, ultrasound clamp, SM with ultrasound reactors were tested. • The 16 × 400 W ultrasound clamps were operated at 20 kHz frequency for US reactor. • The US reactor was clearly superior over the other types of continuous reactor. • The US reactor was the most effective alternative with short reactor length. - Abstract: Four types of continuous reactors, namely plug flow reactor (PF), static mixer reactor (SM), ultrasound clamp on tubular reactor (US), and static mixer combined with ultrasound (SM/US) were compared for their purities of methyl ester in biodiesel production from refined palm oil (RPO). The reactor conditions were: KOH 4, 6, 8, 10, and 12 g L −1 , methanol content 20 vol.%, and under 20 L h −1 RPO flow rate at 60 °C temperature. The highest purity of methyl esters: 81.99 wt.% for PF, 95.70 wt.% for SM, 98.98 wt.% for US, and 97.67 wt.% for SM/US, were achieved with 900 mm, 900 mm, 700 mm, and 900 mm reactor lengths respectively, and 12 g L −1 of KOH was used in all cases. The 16 × 400 W ultrasound clamp was operated at 20 kHz frequency, and among short length reactors the US case was more effective than PF, SM, or SM/US. Moreover, ester purity from the US reactor was slightly decreased by the lowest 4 g L −1 KOH. The US reactor was clearly superior over the other types of continuous reactor, and had the potential to reduce KOH consumption by sonochemical effects on the base-catalyzed transesterification reaction.

  6. Retained Intra-Abdominal Surgical Clamp Complicating Emergency Laparotomy: Incidental Finding on Hysterosalpingogram for Evaluation of Tubal Infertility

    Directory of Open Access Journals (Sweden)

    Adebiyi Gbadebo Adesiyun

    2014-01-01

    Full Text Available The finding of intraperitoneal foreign body complicating surgical intervention broadly remains as an issue of safety in the operative room, a source of emotive concern for the patient, and an upsetting but equally embarrassing situation to the surgeon and the team. However, in the media world, it is a source of sumptuous and captivating headline on the newspaper and to the legal profession, an attractive case to prosecute. A middle age teacher presented with secondary infertility. She had emergency laparotomy fifteen years ago for ruptured tubal ectopic pregnancy in a private hospital and postoperative period was uneventful. Amongst other investigations to find out the cause of infertility, she had hysterosalpingography and a radio-opaque clamp was visualized on the films. She was counselled and had laparotomy. A pair of surgical Kocher clamps was retrieved buried in the mesentery.

  7. A complete dc characterization of a constant-frequency, clamped-mode, series-resonant converter

    Science.gov (United States)

    Tsai, Fu-Sheng; Lee, Fred C.

    1988-01-01

    The dc behavior of a clamped-mode series-resonant converter is characterized systematically. Given a circuit operating condition, the converter's mode of operation is determined and various circuit parameters are calculated, such as average inductor current (load current), rms inductor current, peak capacitor voltage, rms switch currents, average diode currents, switch turn-on currents, and switch turn-off currents. Regions of operation are defined, and various circuit characteristics are derived to facilitate the converter design.

  8. Evaluation of the clamping force in high tension bolt by using the ultrasonic nonlinearity

    International Nuclear Information System (INIS)

    Jang, Kyung Young; Cheon, Hae Wha; Ha, Hob; Park, Man Sick; Kim, No You

    2005-01-01

    High tension bolts have been used widely for the clamping of many kinds of large structure. Therefore, its estimation has been regarded as main issue in the maintenance of high tension bolts. This paper proposes a novel method using the ultrasonic nonlinearity, which is based on the dependency of sound speed on the stress. For this we introduce nonlinear elastic constants in the stress-strain relationship, and derive the sound speed as a linear function of stress. In order to verify the usefulness of the proposed method, two kinds of experiments are carried out: The first one is to measure the sound speed when the bolt is stressed by the tension tester. The result showed good agreement with the expected linear relationship between the sound speed and the axial stress. The second one is to measure the sound speed when the bolt is stressed by the torque wrench. The results showed that the sound speed was decreased when the torque was increased. From these results we can say that the proposed method is enough useful to evaluate the clamping force in the high tension bolt.

  9. Limitations of the dual voltage clamp method in assaying conductance and kinetics of gap junction channels

    NARCIS (Netherlands)

    Wilders, R.; Jongsma, H. J.

    1992-01-01

    The electrical properties of gap junctions in cell pairs are usually studied by means of the dual voltage clamp method. The voltage across the junctional channels, however, cannot be controlled adequately due to an artificial resistance and a natural resistance, both connected in series with the gap

  10. High performance control strategy for single-phase three-level neutral-point-clamped traction four-quadrant converters

    DEFF Research Database (Denmark)

    Kejian, Song; Konstantinou, Georgios; Jing, Li

    2017-01-01

    Operational data from Chinese railways indicate a number of challenges for traction four-quadrant converter (4QC) control including low-order voltage and current harmonics and reference tracking. A control strategy for a single-phase three-level neutral-point-clamped 4QC employed in the electric...

  11. Safety Distances for hydrogen filling stations

    Energy Technology Data Exchange (ETDEWEB)

    Matthijsen, A. J. C. M.; Kooi, E. S.

    2005-07-01

    In the Netherlands there is a growing interest in using natural gas as a transport fuel. The most important drivers behind this development are formed by poor inner city air quality and the decision to close several LPG filling stations. Dwellings are not allowed within the safety distances of 45 or 110 meters from the tanker filling point of these LPG stations, depending on the capacity of the station. Another driver is global warming. We are carrying out a study on station supply, compression, storage and filling for natural gas stations, and a similar, simultaneous study on hydrogen as a followup to our risk analysis for the hydrogen filling station in Amsterdam. Here, three buses drive on hydrogen as part of the European CUTE project. Driving on natural gas is an important step in the transition to cars on hydrogen. This study was commissioned by the Dutch Ministry of Spatial Planning, Housing and the Environment to advise on external safety aspects of future hydrogen filling stations. According to Dutch law homes may not be built within an individual risk contour of 10-6 per year of a dangerous object, such as a plant with hazardous materials or a filling station. An individual risk contour of 10-6 is represented by a line around a dangerous object that connects locations with an individual risk level of 10-6 per year. An individual 'located' within this contour line has a chance of one per million per year or more to be killed as a result of an accident caused by this object. The longest distance between the object and such a contour is called a 'safety distance'. A study on safety distances is now in progress for different kinds of hydrogen filling stations (e. g. gaseous and liquid hydrogen) and for different capacities, such as big, medium and small stations. The focus is on different kinds of hydrogen production and the hydrogen supply of the filling station. To decide on the design and supply of the hydrogen station, we examined the

  12. Socio-economic impacts of nuclear generating stations: Arkansas Nuclear One Station case study

    International Nuclear Information System (INIS)

    Pijawka, K.D.

    1982-07-01

    This report documents a case study of the socio-economic impacts of the construction and operation of the Arkansas Nuclear One nuclear power station. It is part of a major post-licensing study of the socio-economic impacts at twelve nuclear power stations. The case study covers the period beginning with the announcement of plans to construct the reactor and ending in the period 1980 to 1981. The case study deals with changes in the economy, population, settlement patterns and housing, local government and public services, social structure, and public response in the study area during the construction/operation of the reactor. A regional modeling approach is used to trace the impact of construction/operation on the local economy, labor market, and housing market. Emphasis in the study is on the attribution of socio-economic impacts to the reactor or other causal factors. As part of the study of local public response to the construction/operation of the reactor, the effects of the Three Mile Island accident are examined

  13. Single aortic clamping in coronary artery bypass surgery reduces cerebral embolism and improves neurocognitive outcomes.

    Science.gov (United States)

    Gasparovic, Hrvoje; Borojevic, Marko; Malojcic, Branko; Gasparovic, Kristina; Biocina, Bojan

    2013-10-01

    Aortic manipulation releases embolic material, thereby enhancing the probability of adverse neurologic outcomes following coronary artery bypass grafting (CABG). We prospectively evaluated 59 patients undergoing CABG. Patients in the single (SC, n = 37) and multiple clamp (MC, n = 22) groups were comparable in relation to age and operative risk (p > 0.05). Neurocognitive evaluation consisted of the Auditory Verbal Learning Test (AVLT), Color Trails Test A, the Grooved Pegboard test and the Mini-Mental State Examination. Data acquisition was performed preoperatively, early postoperatively and at the 4-month follow-up. Intraoperative transcranial Doppler (TCD) monitoring was used to quantify the embolic load in relation to different aortic clamping strategies. Preoperative neurocognitive results were similar between the groups (p > 0.05). The incidence of postoperative delirium was greater in the MC group but this failed to reach statistical significance (23% vs 8%, p = 0.14). SC patients had fewer embolization signals (270 ± 181 vs 465 ± 160, p cognitive depression was greater in the MC group (p cognition deficits and superior late restoration of function.

  14. Hydrogen fueling stations in Japan hydrogen and fuel cell demonstration project

    International Nuclear Information System (INIS)

    Koseki, K.; Tomuro, J.; Sato, H.; Maruyama, S.

    2004-01-01

    A new national demonstration project of fuel cell vehicles, which is called Japan Hydrogen and Fuel Cell Demonstration Project (JHFC Project), has started in FY2002 on a four-year plan. In this new project, ten hydrogen fueling stations have been constructed in Tokyo and Kanagawa area in FY2002-2003. The ten stations adopt the following different types of fuel and fueling methods: LPG reforming, methanol reforming, naphtha reforming, desulfurized-gasoline reforming, kerosene reforming, natural gas reforming, water electrolysis, liquid hydrogen, by-product hydrogen, and commercially available cylinder hydrogen. Approximately fifty fuel cell passenger cars and a fuel cell bus are running on public roads using these stations. In addition, two hydrogen stations will be constructed in FY2004 in Aichi prefecture where The 2005 World Exposition (EXPO 2005) will be held. The stations will service eight fuel cell buses used as pick-up buses for visitors. We, Engineering Advancement Association of Japan (ENAA), are commissioned to construct and operate a total of twelve stations by Ministry of Economy Trade and Industry (METI). We are executing to demonstrate or identify the energy-saving effect, reduction of the environmental footprint, and issues for facilitating the acceptance of hydrogen stations on the basis of the data obtained from the operation of the stations. (author)

  15. Thermal battery automated assembly station conceptual design

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, D

    1988-08-01

    Thermal battery assembly involves many operations which are labor- intense. In August 1986, a project team was formed at GE Neutron Devices to investigate and evaluate more efficient and productive battery assembly techniques through the use of automation. The result of this study was the acceptance of a plan to automate the piece part pellet fabrication and battery stacking operations by using computerized pellet presses and robots which would be integrated by a main computer. This report details the conceptual design and development plan to be followed in the fabrication, development, and implementation of a thermal battery automated assembly station. 4 figs., 8 tabs.

  16. Architecture for spacecraft operations planning

    Science.gov (United States)

    Davis, William S.

    1991-01-01

    A system which generates plans for the dynamic environment of space operations is discussed. This system synthesizes plans by combining known operations under a set of physical, functional, and temperal constraints from various plan entities, which are modeled independently but combine in a flexible manner to suit dynamic planning needs. This independence allows the generation of a single plan source which can be compiled and applied to a variety of agents. The architecture blends elements of temperal logic, nonlinear planning, and object oriented constraint modeling to achieve its flexibility. This system was applied to the domain of the Intravehicular Activity (IVA) maintenance and repair aboard Space Station Freedom testbed.

  17. A clamping force measurement system for monitoring the condition of bolted joints on railway track joints and points

    International Nuclear Information System (INIS)

    Tesfa, B; Horler, G; Thobiani, F Al; Gu, F; Ball, A D

    2012-01-01

    Many industrial structures associated with railway infrastructures rely on a large number of bolted joint connections to ensure safe and reliable operation of the track and trackside furniture. Significant sums of money are spent annually to repair the damage caused by bolt failures and to maintain the integrity of bolted structures. In the UK, Network Rail (the organization responsible for rail network maintenance and safety) conducts corrective and preventive maintenance manually on 26,000 sets of points (each having approximately 30 bolted joints per set), in order to ensure operational success and safety for the travelling public. Such manual maintenance is costly, disruptive, unreliable and prone to human error. The aim of this work is to provide a means of automatically measuring the clamping force of each individual bolted joint, by means of an instrumented washer. This paper describes the development of a sensor means to be used in the washer, which satisfies the following criteria. 1. Sense changes in the clamping force of the joint and report this fact. 2. Provide compatibility with the large dynamic range of clamping force. 3. Satisfy the limitations in terms of physical size. 4. Provide the means to electronically interface with the washer. 5. Provide a means of powering the washer in situ. 6. Provide a solution at an acceptable cost. Specifically the paper focuses on requirements 1, 2 and 3 and presents the results that support further development of the proposed design and the realization of a pre-prototype system. In the paper, various options for the force sensing element (strain gage, capacitor, piezo-resistive) have been compared, using design optimization techniques. As a result of the evaluation, piezo-resistive sensors in concert with a proprietary force attenuation method, have been found to offer the best performance and cost trade-off The performance of the novel clamping force sensor has been evaluated experimentally and the results show

  18. Space Station Freedom (SSF) Data Management System (DMS) performance model data base

    Science.gov (United States)

    Stovall, John R.

    1993-01-01

    The purpose of this document was originally to be a working document summarizing Space Station Freedom (SSF) Data Management System (DMS) hardware and software design, configuration, performance and estimated loading data from a myriad of source documents such that the parameters provided could be used to build a dynamic performance model of the DMS. The document is published at this time as a close-out of the DMS performance modeling effort resulting from the Clinton Administration mandated Space Station Redesign. The DMS as documented in this report is no longer a part of the redesigned Space Station. The performance modeling effort was a joint undertaking between the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) Flight Data Systems Division (FDSD) and the NASA Ames Research Center (ARC) Spacecraft Data Systems Research Branch. The scope of this document is limited to the DMS core network through the Man Tended Configuration (MTC) as it existed prior to the 1993 Clinton Administration mandated Space Station Redesign. Data is provided for the Standard Data Processors (SDP's), Multiplexer/Demultiplexers (MDM's) and Mass Storage Units (MSU's). Planned future releases would have added the additional hardware and software descriptions needed to describe the complete DMS. Performance and loading data through the Permanent Manned Configuration (PMC) was to have been included as it became available. No future releases of this document are presently planned pending completion of the present Space Station Redesign activities and task reassessment.

  19. Intelligent control of a planning system for astronaut training.

    Science.gov (United States)

    Ortiz, J; Chen, G

    1999-07-01

    This work intends to design, analyze and solve, from the systems control perspective, a complex, dynamic, and multiconstrained planning system for generating training plans for crew members of the NASA-led International Space Station. Various intelligent planning systems have been developed within the framework of artificial intelligence. These planning systems generally lack a rigorous mathematical formalism to allow a reliable and flexible methodology for their design, modeling, and performance analysis in a dynamical, time-critical, and multiconstrained environment. Formulating the planning problem in the domain of discrete-event systems under a unified framework such that it can be modeled, designed, and analyzed as a control system will provide a self-contained theory for such planning systems. This will also provide a means to certify various planning systems for operations in the dynamical and complex environments in space. The work presented here completes the design, development, and analysis of an intricate, large-scale, and representative mathematical formulation for intelligent control of a real planning system for Space Station crew training. This planning system has been tested and used at NASA-Johnson Space Center.

  20. Aspects of safety and of functional construction and configuration in planning and designing nuclear heating stations

    International Nuclear Information System (INIS)

    Adam, E.; Mueller, R.; Boettger, M.; Kremtz, U.

    1982-01-01

    The present studies are based on the design of a technological project of a nuclear heating station with a unit power of 250 MW. Essentially, this nuclear heating station is a three-circuit plant, the primary coolant circuit being based on natural circulation through the reactor vessel with integrated heat exchangers. Starting from the social objective and the derived development structure of the territory, the siting problems in integrating the nuclear heating stations have to be solved. On the basis of the resulting dimensions of the containment the technical and economical specifications of different versions of containment design are evaluated. (author)

  1. 40 CFR 52.430 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Photochemical Assessment Monitoring Stations (PAMS) Program. 52.430 Section 52.430 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Natural Resources & Environmental Control submitted a plan for the establishment and implementation of a...

  2. 40 CFR 52.480 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... of Columbia's Department of Consumer and Regulatory Affairs submitted a plan for the establishment... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Photochemical Assessment Monitoring Stations (PAMS) Program. 52.480 Section 52.480 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...

  3. Streamflow characteristics at hydrologic bench-mark stations

    Science.gov (United States)

    Lawrence, C.L.

    1987-01-01

    The Hydrologic Bench-Mark Network was established in the 1960's. Its objectives were to document the hydrologic characteristics of representative undeveloped watersheds nationwide and to provide a comparative base for studying the effects of man on the hydrologic environment. The network, which consists of 57 streamflow gaging stations and one lake-stage station in 39 States, is planned for permanent operation. This interim report describes streamflow characteristics at each bench-mark site and identifies time trends in annual streamflow that have occurred during the data-collection period. The streamflow characteristics presented for each streamflow station are (1) flood and low-flow frequencies, (2) flow duration, (3) annual mean flow, and (4) the serial correlation coefficient for annual mean discharge. In addition, Kendall's tau is computed as an indicator of time trend in annual discharges. The period of record for most stations was 13 to 17 years, although several stations had longer periods of record. The longest period was 65 years for Merced River near Yosemite, Calif. Records of flow at 6 of 57 streamflow sites in the network showed a statistically significant change in annual mean discharge over the period of record, based on computations of Kendall's tau. The values of Kendall's tau ranged from -0.533 to 0.648. An examination of climatological records showed that changes in precipitation were most likely the cause for the change in annual mean discharge.

  4. Modulation Methods for Three-level Neutral-Point-Clamped Inverter Achieving Stress Redistribution under Moderate Modulation Index

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2016-01-01

    This letter investigates the loss and thermal behaviors of a three-level neutral-point-clamped (3L-NPC) inverter undergoing moderate modulation index, which is typically presented during minor voltage sags of the power grid or speed changes of the electric machines. A series of new space vector m...

  5. Utilization of artificial intelligence techniques for the Space Station power system

    Science.gov (United States)

    Evatt, Thomas C.; Gholdston, Edward W.

    1988-01-01

    Due to the complexity of the Space Station Electrical Power System (EPS) as currently envisioned, artificial intelligence/expert system techniques are being investigated to automate operations, maintenance, and diagnostic functions. A study was conducted to investigate this technology as it applies to failure detection, isolation, and reconfiguration (FDIR) and health monitoring of power system components and of the total system. Control system utilization of expert systems for load scheduling and shedding operations was also researched. A discussion of the utilization of artificial intelligence/expert systems for Initial Operating Capability (IOC) for the Space Station effort is presented along with future plans at Rocketdyne for the utilization of this technology for enhanced Space Station power capability.

  6. High level waste (HLW) steam reducing station evaluation

    International Nuclear Information System (INIS)

    Gannon, R.E.

    1993-01-01

    Existing pressure equipment in High Level Waste does not have a documented technical baseline. Based on preliminary reviews, the existing equipment seems to be based on system required capacity instead of system capability. A planned approach to establish a technical baseline began September 1992 and used the Works Management System preventive maintenance schedule. Several issues with relief valves being undersized on steam reducing stations created a need to determine the risk of maintaining the steam in service. An Action Plan was developed to evaluate relief valves that did not have technical baselines and provided a path forward for continued operation. Based on Action Plan WER-HLE-931042, the steam systems will remain in service while the designs are being developed and implemented

  7. SA silent on talk of a second nuclear station

    International Nuclear Information System (INIS)

    Waddacor, M.

    1983-01-01

    Local nuclear energy officials have either denied or will not comment on recent European reports suggesting South Africa plans to construct a second nuclear power station. The probability of South Africa building a second nuclear power plant is discussed. The recent sabotage at the Koeberg-1 reactor is also mentioned

  8. Estimation of Remote Microclimates from Weather Station Data with Applications to Landscape Architecture.

    Science.gov (United States)

    Brown, Robert Douglas

    Several components of a system for quantitative application of climatic statistics to landscape planning and design (CLIMACS) have been developed. One component model (MICROSIM) estimated the microclimate at the top of a remote crop using physically-based models and inputs of weather station data. Temperatures at the top of unstressed, uniform crops on flat terrain within 1600 m of a recording weather station were estimated within 1.0 C 96% of the time for a corn crop and 92% of the time for a soybean crop. Crop top winds were estimated within 0.4 m/s 92% of the time for corn and 100% of the time for soybean. This is of sufficient accuracy for application in landscape planning and design models. A physically-based model (COMFA) was developed for the determination of outdoor human thermal comfort from microclimate inputs. Estimated versus measured comfort levels in a wide range of environments agreed with a correlation coefficient of r = 0.91. Using these components, the CLIMACS concept has been applied to a typical planning example. Microclimate data were generated from weather station information using MICROSIM, then input to COMFA and to a house energy consumption model called HOTCAN to derive quantitative climatic justification for design decisions.

  9. Inspection maintenance and planning of shutdown in thermal electric generating plants

    International Nuclear Information System (INIS)

    Dezordi, W.L.; Correa, D.A.; Kina, M.

    1984-01-01

    The schedule shutdown of an industrial plant and, more specifically, of an electrical generating station, is becoming increasingly important. The major parameters to be taken into account for the planning of such a shutdown are basically of economic-financial nature such as costs of the related services (materials, equipment, manpower, etc), loss of revenue caused by the station's shutdown as well as by the station availability, and other requirements expected from it by the Load Dispatch and consumers. Improving the equipment's performances and the station's availability are the fundamental objectives to be strived for. The authors present in this paper, in an abridged form, the planning tools used for thermal electric generating plants shutdowns for inspections, maintenance and design changes implementation. (Author) [pt

  10. Improved non-dimensional dynamic influence function method for vibration analysis of arbitrarily shaped plates with clamped edges

    Directory of Open Access Journals (Sweden)

    Sang-Wook Kang

    2016-03-01

    Full Text Available A new formulation for the non-dimensional dynamic influence function method, which was developed by the authors, is proposed to efficiently extract eigenvalues and mode shapes of clamped plates with arbitrary shapes. Compared with the finite element and boundary element methods, the non-dimensional dynamic influence function method yields highly accurate solutions in eigenvalue analysis problems of plates and membranes including acoustic cavities. However, the non-dimensional dynamic influence function method requires the uneconomic procedure of calculating the singularity of a system matrix in the frequency range of interest for extracting eigenvalues because it produces a non-algebraic eigenvalue problem. This article describes a new approach that reduces the problem of free vibrations of clamped plates to an algebraic eigenvalue problem, the solution of which is straightforward. The validity and efficiency of the proposed method are illustrated through several numerical examples.

  11. The impact of social franchising on the use of reproductive health and family planning services at public commune health stations in Vietnam.

    Science.gov (United States)

    Ngo, Anh D; Alden, Dana L; Pham, Van; Phan, Ha

    2010-02-28

    Service franchising is a business model that involves building a network of outlets (franchisees) that are locally owned, but act in coordinated manner with the guidance of a central headquarters (franchisor). The franchisor maintains quality standards, provides managerial training, conducts centralized purchasing and promotes a common brand. Research indicates that franchising private reproductive health and family planning (RHFP) services in developing countries improves quality and utilization. However, there is very little evidence that franchising improves RHFP services delivered through community-based public health clinics. This study evaluates behavioral outcomes associated with a new approach - the Government Social Franchise (GSF) model - developed to improve RHFP service quality and capacity in Vietnam's commune health stations (CHSs). The project involved networking and branding 36 commune health station (CHS) clinics in two central provinces of Da Nang and Khanh Hoa, Vietnam. A quasi-experimental design with 36 control CHSs assessed GSF model effects on client use as measured by: 1) clinic-reported client volume; 2) the proportion of self-reported RHFP service users at participating CHS clinics over the total sample of respondents; and 3) self-reported RHFP service use frequency. Monthly clinic records were analyzed. In addition, household surveys of 1,181 CHS users and potential users were conducted prior to launch and then 6 and 12 months after implementing the GSF network. Regression analyses controlled for baseline differences between intervention and control groups. CHS franchise membership was significantly associated with a 40% plus increase in clinic-reported client volumes for both reproductive and general health services. A 45% increase in clinic-reported family planning service clients related to GSF membership was marginally significant (p = 0.05). Self-reported frequency of RHFP service use increased by 20% from the baseline survey to the

  12. An example of the practical application of ALARP in planning, implementation and review at BNFL's Bradwell Power Station

    International Nuclear Information System (INIS)

    Devine, I.R.; James, C.

    2000-01-01

    The paper will describe three examples of the practical application of ALARP principles as applied to some major projects associated with enhancement of the safety cases for heat exchanger or reactor core support structures at some Magnox Power Stations operated by BNFL Magnox Generation. It will summarise and discuss some of the issues encountered during the pre-planning, engineering development/implementation, work in progress and post completion review phases. The first example is the response to minor defects discovered during an inspection of a sample of some welds in an upper restraint beam inside the concrete reactor pressure vessel at Oldbury Power Station. These inspections were carried out to enhance the existing safety case to justify a proposed increase in the period between statutory inspections from two to three years. The presence or absence of similar defects in the other welds was not sufficiently well characterised nor could be sufficiently accurately predicted without extensive additional NDT inspection. This would in itself have incurred a significant dose commitment. The engineering/ALARP assessment was required address the justification of the work and even determine what should be proposed. Available options included: extensive inspection to determine the status of load bearing welds to enable a subsequent assessment of the required remedial work (if any) which may include weld dressing, repair or reinforcement; pre-emptive reinforcement on a 'worst case scenario', or pre-emptive complete or partial weld repair. The second and third case studies relate to the response to minor defects in welds associated with support beams inside heat exchangers at Bradwell and Hinkley Point Power Stations. In these cases, pre-emptive repair or reinforcement was clearly justified and optimal. The engineering/ALARP assessments were required to address the optimisation of the required repair or reinforcement strategy and tasks associated with its implementation

  13. Transceiver for Space Station Freedom

    Science.gov (United States)

    Fitzmaurice, M.; Bruno, R.

    1990-07-01

    This paper describes the design of the Laser Communication Transceiver (LCT) system which was planned to be flight tested as an attached payload on Space Station Freedom. The objective in building and flight-testing the LCT is to perform a broad class of tests addressing the critical aspects of space-based optical communications systems, providing a base of experience for applying laser communications technology toward future communications needs. The LCT's functional and performance requirements and capabilities with respect to acquisition, spatial tracking and pointing, communications, and attitude determination are discussed.

  14. Two unique ligand-binding clamps of Rhizopus oryzae starch binding domain for helical structure disruption of amylose.

    Directory of Open Access Journals (Sweden)

    Ting-Ying Jiang

    Full Text Available The N-terminal starch binding domain of Rhizopus oryzae glucoamylase (RoSBD has a high binding affinity for raw starch. RoSBD has two ligand-binding sites, each containing a ligand-binding clamp: a polyN clamp residing near binding site I is unique in that it is expressed in only three members of carbohydrate binding module family 21 (CBM21 members, and a Y32/F58 clamp located at binding site II is conserved in several CBMs. Here we characterized different roles of these sites in the binding of insoluble and soluble starches using an amylose-iodine complex assay, atomic force microscopy, isothermal titration calorimetry, site-directed mutagenesis, and structural bioinformatics. RoSBD induced the release of iodine from the amylose helical cavity and disrupted the helical structure of amylose type III, thereby significantly diminishing the thickness and length of the amylose type III fibrils. A point mutation in the critical ligand-binding residues of sites I and II, however, reduced both the binding affinity and amylose helix disruption. This is the first molecular model for structure disruption of the amylose helix by a non-hydrolytic CBM21 member. RoSBD apparently twists the helical amylose strands apart to expose more ligand surface for further SBD binding. Repeating the process triggers the relaxation and unwinding of amylose helices to generate thinner and shorter amylose fibrils, which are more susceptible to hydrolysis by glucoamylase. This model aids in understanding the natural roles of CBMs in protein-glycan interactions and contributes to potential molecular engineering of CBMs.

  15. Research on Layout Optimization of Urban Circle Solid Waste Transfer and Disposal Stations

    OpenAIRE

    Xuhui Li; Gangyan Li; Guowen Sun; Huiping Shi; Bao’an Yang

    2013-01-01

    Based on the Systematic Layout Planning theory and the analysis of transfer stations’ technological processes, a layout optimization model for solid waste transfer and disposal stations was made. The operating units’ layout of the solid waste transfer and disposal stations was simulated and optimized using the genetic algorithm, which could achieve reasonable technological processes, the smallest floor space and the lowest construction cost. The simulation result can also direct t...

  16. Application exploration of primavera6.0 for design-schedule in nuclear power station

    International Nuclear Information System (INIS)

    Zhang Xiaoping

    2009-01-01

    The ideas and flow of plan establishment during the nuclear power station design is discussed in this paper, including the main steps in the plan establishment, and the design schedule and the management of documents and interfaces are improved. An integral design management innovation is proposed for the management of 'schedule, interfaces and drawings and files'. (authors)

  17. Gaseous Non-Premixed Flame Research Planned for the International Space Station

    Science.gov (United States)

    Stocker, Dennis P.; Takahashi, Fumiaki; Hickman, J. Mark; Suttles, Andrew C.

    2014-01-01

    Thus far, studies of gaseous diffusion flames on the International Space Station (ISS) have been limited to research conducted in the Microgravity Science Glovebox (MSG) in mid-2009 and early 2012. The research was performed with limited instrumentation, but novel techniques allowed for the determination of the soot temperature and volume fraction. Development is now underway for the next experiments of this type. The Advanced Combustion via Microgravity Experiments (ACME) project consists of five independent experiments that will be conducted with expanded instrumentation within the stations Combustion Integrated Rack (CIR). ACMEs goals are to improve our understanding of flame stability and extinction limits, soot control and reduction, oxygen-enriched combustion which could enable practical carbon sequestration, combustion at fuel lean conditions where both optimum performance and low emissions can be achieved, the use of electric fields for combustion control, and materials flammability. The microgravity environment provides longer residence times and larger length scales, yielding a broad range of flame conditions which are beneficial for simplified analysis, e.g., of limit behaviour where chemical kinetics are important. The detailed design of the modular ACME hardware, e.g., with exchangeable burners, is nearing completion, and it is expected that on-orbit testing will begin in 2016.

  18. A New Approach of Modified Submerged Patch Clamp Recording Reveals Interneuronal Dynamics during Epileptiform Oscillations

    Czech Academy of Sciences Publication Activity Database

    Morris, G.; Jiruška, Přemysl; Jefferys, J. G. R.; Powell, A. D.

    2016-01-01

    Roč. 10, Nov 9 (2016), č. článku 519. ISSN 1662-453X R&D Projects: GA ČR(CZ) GA14-02634S; GA MZd(CZ) NV15-29835A Institutional support: RVO:67985823 Keywords : in vitro * membrane chamber * LFP * patch clamp * epilepsy * high frequency activity Subject RIV: FH - Neurology Impact factor: 3.566, year: 2016

  19. Plan and present status of synchrotron radiation applications at HESYRL

    International Nuclear Information System (INIS)

    Zhang, Y.; Su, Y.; Qian, S.; Xu, X.; Jiang, D.; Xu, C.

    1985-01-01

    An 800 MeV electron storage ring is being constructed at Hefei, China. It is a dedicated UV synchrotron light source from which 27 beam lines could be extracted to accommodate about 50 experimental stations. Four beam lines and five stations are planned and some instruments have been designed and are under construction for the first five-year plan. The proposed experiments include x-ray lithography, soft x-ray microscopy, photoelectron spectroscopy, time-resolved spectroscopy and photochemistry

  20. Agent independent task planning

    Science.gov (United States)

    Davis, William S.

    1990-01-01

    Agent-Independent Planning is a technique that allows the construction of activity plans without regard to the agent that will perform them. Once generated, a plan is then validated and translated into instructions for a particular agent, whether a robot, crewmember, or software-based control system. Because Space Station Freedom (SSF) is planned for orbital operations for approximately thirty years, it will almost certainly experience numerous enhancements and upgrades, including upgrades in robotic manipulators. Agent-Independent Planning provides the capability to construct plans for SSF operations, independent of specific robotic systems, by combining techniques of object oriented modeling, nonlinear planning and temporal logic. Since a plan is validated using the physical and functional models of a particular agent, new robotic systems can be developed and integrated with existing operations in a robust manner. This technique also provides the capability to generate plans for crewmembers with varying skill levels, and later apply these same plans to more sophisticated robotic manipulators made available by evolutions in technology.

  1. Development of a peptide nucleic acid polymerase chain reaction clamping assay for semiquantitative evaluation of genetically modified organism content in food.

    Science.gov (United States)

    Peano, C; Lesignoli, F; Gulli, M; Corradini, R; Samson, M C; Marchelli, R; Marmiroli, N

    2005-09-15

    In the present study a peptide nucleic acid (PNA)-mediated polymerase chain reaction (PCR) clamping method was developed and applied to the detection of genetically modified organisms (GMO), to test PCR products for band identity and to obtain a semiquantitative evaluation of GMO content. The minimal concentration of PNA necessary to block the PCR was determined by comparing PCRs containing a constant amount of DNA in the presence of increasing concentration of target-specific PNA. The lowest PNA concentration at which specific inhibition took place, by the inhibition of primer extension and/or steric hindrance, was the most efficient condition. Optimization of PCR clamping by PNA was observed by testing five different PNAs with a minimum of 13 bp to a maximum of 15 bp, designed on the target sequence of Roundup Ready soybean. The results obtained on the DNA extracted from Roundup Ready soybean standard flour were verified also on DNA extracted from standard flours of maize GA21, Bt176, Bt11, and MON810. A correlation between the PNA concentration necessary for inducing PCR clamping and the percentage of the GMO target sequence in the sample was found.

  2. Multiple Charging Station Location-Routing Problem with Time Window of Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Wang Li-ying

    2015-11-01

    Full Text Available This paper presents the electric vehicle (EV multiple charging station location-routing problem with time window to optimize the routing plan of capacitated EVs and the strategy of charging stations. In particular, the strategy of charging stations includes both infrastructure-type selection and station location decisions. The problem accounts for two critical constraints in logistic practice: the vehicle loading capacity and the customer time windows. A hybrid heuristic that incorporates an adaptive variable neighborhood search (AVNS with the tabu search algorithm for intensification was developed to address the problem. The specialized neighborhood structures and the selection methods of charging station used in the shaking step of AVNS were proposed. In contrast to the commercial solver CPLEX, experimental results on small-scale test instances demonstrate that the algorithm can find nearly optimal solutions on small-scale instances. The results on large-scale instances also show the effectiveness of the algorithm.

  3. Damodar Valley Corporation, Chandrapura Unit 2 Thermal Power Station Residual Life Assessment Summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-01

    The BHEL/NTPC/PFC/TVA teams assembled at the DVC`s Chadrapura station on July 19, 1994, to assess the remaining life of Unit 2. The workscope was expanded to include major plant systems that impact the unit`s ability to sustain generation at 140 MW (Units 1-3 have operated at average rating of about 90 MW). Assessment was completed Aug. 19, 1994. Boiler pressure parts are in excellent condition except for damage to primary superheater header/stub tubes and economizer inlet header stub tubes. The turbine steam path is in good condition except for damage to LP blading; the spar rotor steam path is in better condition and is recommended for Unit 2. Nozzle box struts are severely cracked from the flame outs; the cracks should not be repaired. HP/IP rotor has surface cracks at several places along the steam seal areas; these cracks are shallow and should be machined out. Detailed component damage assessments for above damaged components have been done. The turbine auxiliary systems have been evaluated; cooling tower fouling/blockage is the root cause for the high turbine back pressure. The fuel processing system is one of the primary root causes for limiting unit capacity. The main steam and hot reheat piping systems were conservatively designed and have at least 30 years left;deficiencies needing resolution include restoration of insulation, replacement of 6 deformed hanger clamp/bolts, and adjustment of a few hanger settings. The cold reheat piping system is generally in good condition; some areas should be re-insulated and the rigid support clamps/bolts should be examined. The turbine extraction piping system supports all appeared to be functioning normally.

  4. Refurbishment of Point Lepreau Generating Station

    International Nuclear Information System (INIS)

    Thompson, P.D.; Jaitly, R.; Ichiyen, N.; Petrilli, M.A.

    2004-01-01

    NB Power is planning to conduct an 18-month maintenance outage of the Point Lepreau Generating Station (PLGS) beginning in April 2008. The major activity would be the replacement of all 380 Fuel Channel and Calandria Tube Assemblies and the connecting feeder pipes. This activity is referred to as Retube. NB Power would also take advantage of this outage to conduct a number of repairs, replacements, inspections and upgrades (such as rewinding or replacing the generator, replacement of shutdown system trip computers, replacement of certain valves and expansion joints, inspection of systems not normally accessible, etc). These collective activities are referred to as Refurbishment. This would allow the station to operate for an additional 25 to 30 years. The scope of the project was determined from the outcome of a two-year study involving a detailed condition assessment of the station that examined issues relating to ageing and obsolescence. The majority of the plant components were found to be capable of supporting extended operation without needing replacement or changes. In addition to the condition assessment, a detailed review of Safety and Licensing issues associated with extended operation was performed. This included a review of known regulatory and safety issues, comparison of the station against current codes and standards, and comparison of the station against safety related modifications made to more recent CANDU 6 units. Benefit cost analyses (BCA) were performed to assist the utility in determining which changes were appropriate to include in the project scope. As a Probabilistic Safety Assessment (PSA) for PLGS did not exist at the time, a risk baseline for the station had to be determined for use in the BCA. Extensive dialogue with the Canadian Nuclear Safety Commission staff was also undertaken during this phase. A comprehensive Licensing Framework was produced upon which the CNSC provided feedback to NB Power. This feedback was important in terms of

  5. Ventilatory effects of hypercapnic end-tidal PCO2 clamps during aerobic exercise of varying intensity.

    Science.gov (United States)

    Essfeld, D; Hoffmann, U; Stegemann, J

    1990-01-01

    Nine subjects performed a sequence of sustained and randomised changes between 40 W and 100 W on a cycle ergometer while the end-tidal PO2 was kept close to 17.3 kPa (130 mm Hg) by means of a dynamic forcing technique (reference experiment). In a second series inspiratory CO2 was additionally manipulated so as to hold end-tidal PCO2 (PETCO2) near 6.5 kPa (49 mm Hg; 'CO2-clamp' experiment). By this forcing PETCO2 oscillations were attenuated and more evenly distributed over the frequency range. Ventilation (VT) responded to this manoeuvre with an upward trend that could not be ascribed to a slow CO2-response component, changes in metabolic rate or a dissociation of end-tidal and arterial PCO2. VT differences between reference and CO2-clamp experiments were abolished within a 3-min period following the termination of the external CO2 control. The present results suggest that the CO2-H+ stimulus plays a major role in adjusting ventilation when exercise intensity is decreased. The underlying CO2 effect appears to be neither additive nor bi-directionally symmetrical.

  6. Nuclear safeguards control in nuclear power stations

    International Nuclear Information System (INIS)

    Boedege, R.; Braatz, U.; Heger, H.

    1976-01-01

    The execution of the Non-Proliferation Treaty (NPT) has initiated a third phase in the efforts taken to ensure peace by limiting the number of atomic powers. In this phase it is important, above all, to turn into workable systems the conditions imposed upon technology by the different provisions of the Verification Agreement of the NPT. This is achieved mainly by elaborating annexes to the Agreement specifically geared to certain model plants, typical representatives selected for LWR power stations being the plants at Garigliano, Italy (BWR), and Stade, Federal Republic of Germany (PWR). The surveillance measures taken to prevent any diversion of special nuclear material for purposes of nuclear weapons manufacture must be effective in achieving their specific objective and must not impede the circumspect management of operations of the plants concerned. A VDEW working party has studied the technical details of the planned surveillance measures in nuclear power stations in the Federal Republic of Germany and now presents a concept of material balancing by units which meets the conditions imposed by the inspection authority and could also be accepted by the operators of nuclear power stations. The concept provides for uninterrupted control of the material balance areas of the nuclear power stations concerned, allows continuous control of the whole nuclear fuel cycle, is based exclusively on existing methods and facilities, and can be implemented at low cost. (orig.) [de

  7. Designing a Signal Conditioning System with Software Calibration for Resistor-feedback Patch Clamp Amplifier.

    Science.gov (United States)

    Hu, Gang; Zhu, Quanhui; Qu, Anlian

    2005-01-01

    In this paper, a programmable signal conditioning system based on software calibration for resistor-feedback patch clamp amplifier (PCA) has been described, this system is mainly composed of frequency correction, programmable gain and filter whose parameters are configured by software automatically to minimize the errors, A lab-designed data acquisition system (DAQ) is used to implement data collections and communications with PC. The laboratory test results show good agreement with design specifications.

  8. Hinkley Point 'C' power station public inquiry: proof of evidence on plant parameters

    International Nuclear Information System (INIS)

    George, B.V.

    1988-09-01

    A public inquiry has been set up to examine the planning application made by the Central Electricity Generating Board (CEGB) for the construction of a 1200 MW Pressurized Water Reactor power station at Hinkley Point (Hinkley Point ''C'') in the United Kingdom. The overall economics of a nuclear power station depends on many factors which are determined by the design; the effectiveness with which the station is constructed; and the performance of the plant. In this respect the most significant factors are: construction time; capital cost; availability of the plant to produce electricity, taking account of those outages due to either planned or unplanned shutdowns; net electrical power output; and the working life of the plant. In this evidence to the Inquiry, the basis for the values chosen as ''targets'' for these parameters in the design of the plant and the control of the project is set out. The adjustment of the parameters to make them suitable for economic appraisal is explained. The design and project management arrangements are described. (author)

  9. The Prospect of Solar Energy in the Development of Power Stations in the State of Kuwait

    Directory of Open Access Journals (Sweden)

    Mohammad Ramadhan

    2013-01-01

    Full Text Available Over the years, the production capacity for power generation has not been able to keep pace with the surge in electricity demand in the oil-rich State of Kuwait. To expand its power generation capacity, Kuwait's strategic energy plans focus on constructing gas turbine and fuel oil stations. This paper aimed to evaluate the prospect of photovoltaic solar energy (PV in generating electricity as an alternative to decrease dependency on combined cycle gas turbine (CCGT power stations. It applies the LCOE framework to evaluate the economic feasibility of installing a 100 MW PV and CCGT power stations in Kuwait. The results indicate that under the assumption of 5% interest rate, the estimated LCOE of PV station ($0.19/kWh is unfeasible in comparison to the generation cost of gas turbine station ($0.11/kWh. However, the analysis has emphasized that evaluation of future electricity generation plans must not be limited to the LCOE criteria and should incorporate the following factors: the effect of natural gas supply constraints on the production of gas turbine plants, the environmental concerns of CO2 emissions, the peak load demand, and the domestic energy balance mix. The paper concludes that once these factors are addressed properly, the prospect of PV power stations becomes relatively feasible.

  10. Study of the method of placing technical stations

    Directory of Open Access Journals (Sweden)

    Sattorov S.B.

    2017-12-01

    Full Text Available At present, the organization of transportation by rail is associated with the processing of trains and wagons along the route. Accommodation and equipping of technical stations play a major role in the organization of the transportation process. The uninterrupted operation of the technical stations ensures the stability of the railway transport as a whole. The distance between the technical stations determines the duration of operation of the locomotive crew, the efficient use of the locomotive, the required number of locomotive crews and locomotives for carrying out the transportation plan, and also improves the main indicators of the railway. However, often train locomotives do not fulfill their assigned tasks due to the lack of time for the locomotive crew in order to deliver the train to the nearest technical station, as well as the irrational use of the standard time of the locomotive crew. In connection with the expectation of delivery, the locomotive brigade replacing the locomotive, the idle time of the wagons at the intermediate stations increases. All this makes it difficult to control the movement of trains and reduces the speed of moving cars on the railway transport. The purpose of the study is to develop a method for placing technical stations on a railway test site in the course of an electric traction. To achieve this goal, it will be necessary to solve the following tasks: generalization of the main parameters of the location of technical stations; determination of half-races between technical stations in the operation of one locomotive brigade; search for the required number of change of the locomotive brigade; determination of the distance between technical stations. The methods of research are based on the generalization and analysis of existing results in finding the rational location of technical stations. Results: It is revealed that the first step for the rational placement of technical stations is to determine the

  11. Material screening with HPGe counting station for PandaX experiment

    International Nuclear Information System (INIS)

    Wang, X.; Chen, X.; Fu, C.; Ji, X.; Liu, X.; Xie, P.; Zhang, T.; Mao, Y.; Wang, S.; Wang, H.

    2016-01-01

    A gamma counting station based on high-purity germanium (HPGe) detector was set up for the material screening of the PandaX dark matter experiments in the China Jinping Underground Laboratory. Low background gamma rate of 2.6 counts/min within the energy range of 20 to 2700 keV is achieved due to the well-designed passive shield. The sentivities of the HPGe detetector reach mBq/kg level for isotopes like K, U, Th, and even better for Co and Cs, resulted from the low-background rate and the high relative detection efficiency of 175%. The structure and performance of the counting station are described in this article. Detailed counting results for the radioactivity in materials used by the PandaX dark-matter experiment are presented. The upgrading plan of the counting station is also discussed.

  12. On the Effect of Clamping Pressure and Method on the Current Mapping of Proton Exchange Membrane Water Electrolysis

    DEFF Research Database (Denmark)

    Al Shakhshir, Saher; Zhou, Fan; Kær, Søren Knudsen

    The degradation of the electrochemical reaction of the proton exchange membrane water electrolysis (PEMWE) can be characterized using in-situ current mapping measurements (CMM). CMM is significantly affected by the amount of clamping pressure and method. In this work the current is mapped...

  13. Public education programme for nuclear contingency planning in Hong Kong

    International Nuclear Information System (INIS)

    Wong, M. C.; Li, S. W.

    2002-01-01

    Two nuclear power stations on the coast of southern China are situated some 50 kilometers to the northeast of Hong Kong. Although the stations are far away from Hong Kong, the construction and operation of the nuclear power stations have generated public anxiety locally, in particular, after the Chernobyl accident in 1986. A comprehensive contingency plan which takes into account such concerns of the public has been implemented in Hong Kong. Cooperation by the public is vital to the effective implementation of any contingency plan. Understanding of the basics of radiation protection as well as the contingency plan will help the public to appreciate the situation and react in a rational manner. A public education program to promote awareness of the contingency plan has been implemented in Hong Kong. In particular, a Virtual Exhibition Hall on radiation has been developed and launched in February 2002 for access by the public via Internet. A video and a set of web pages will be launched in the later part of 2002 to inform and educate the public on matters related to nuclear accident response in Hong Kong. This paper describes the public education programme in Hong Kong to promote public awareness and understanding of the nuclear contingency plan

  14. Space Station Freedom pressurized element interior design process

    Science.gov (United States)

    Hopson, George D.; Aaron, John; Grant, Richard L.

    1990-01-01

    The process used to develop the on-orbit working and living environment of the Space Station Freedom has some very unique constraints and conditions to satisfy. The goal is to provide maximum efficiency and utilization of the available space, in on-orbit, zero G conditions that establishes a comfortable, productive, and safe working environment for the crew. The Space Station Freedom on-orbit living and working space can be divided into support for three major functions: (1) operations, maintenance, and management of the station; (2) conduct of experiments, both directly in the laboratories and remotely for experiments outside the pressurized environment; and (3) crew related functions for food preparation, housekeeping, storage, personal hygiene, health maintenance, zero G environment conditioning, and individual privacy, and rest. The process used to implement these functions, the major requirements driving the design, unique considerations and constraints that influence the design, and summaries of the analysis performed to establish the current configurations are described. Sketches and pictures showing the layout and internal arrangement of the Nodes, U.S. Laboratory and Habitation modules identify the current design relationships of the common and unique station housekeeping subsystems. The crew facilities, work stations, food preparation and eating areas (galley and wardroom), and exercise/health maintenance configurations, waste management and personal hygiene area configuration are shown. U.S. Laboratory experiment facilities and maintenance work areas planned to support the wide variety and mixtures of life science and materials processing payloads are described.

  15. Demand prediction model for regional railway services considering spatial effects between stations

    Energy Technology Data Exchange (ETDEWEB)

    Cordera Piñera, R.; Sañudo, R.; Olio, L. Dell' ; Ibeas, A.

    2016-07-01

    The railways are a priority transport mode for the European Union given their safety record and environmental sustainability. Therefore it is important to have quantitative models available which allow passenger demand for rail travel to be simulated for planning purposes and to evaluate different policies. The aim of this article is to specify and estimate trip distribution models between railway stations by considering the most influential demand variables. Two types of models were estimated: Poisson regression and gravity. The input data were the ticket sales on a regional line in Cantabria (Spain) which were provided by the Spanish railway infrastructure administrator (ADIF – RAM). The models have also considered the possible existence of spatial effects between train stations. The results show that the models have a good fit to the available data, especial the gravity models constrained by origins and destinations. Furthermore, the gravity models which considered the existence of spatial effects between stations had a significantly better fit than the Poisson models and the gravity models that did not consider this phenomenon. The proposed models have therefore been shown to be good support tools for decision making in the field of railway planning. (Author)

  16. Determining the Optimal Layout Design for Public Bicycle System within the Attractive Scope of a Metro Station

    Directory of Open Access Journals (Sweden)

    Jingxu Chen

    2015-01-01

    Full Text Available Public bicycle acts as a seamless feeder mode in combination with the citywide public transit, as well as a competitor for the inner-city short trips. The primary objective of this study is to address the layout planning of public bicycle system within the attracted scope of a metro station. Based on the land use function, population, and bicycle mode share, bicycle rental stations are divided into three types, namely, the metro station, district station, and resident station, and later the quantity of bicycle facilities in each rental station is estimated. Then, the service stations are selected from these bicycle rental stations to provide the service of periodical bicycle redistribution. An improved immune algorithm is proposed to determine the number and locations of service stations and the optimal route options for the implement of redistributing strategy. Finally, a case study of Nanjing Tianyin Road metro station is conducted to illustrate the proposed model and clarify some of its implementation details.

  17. An equivalent network representation of a clamped bimorph piezoelectric micromachined ultrasonic transducer with circular and annular electrodes using matrix manipulation techniques.

    Science.gov (United States)

    Sammoura, Firas; Smyth, Katherine; Kim, Sang-Gook

    2013-09-01

    An electric circuit model for a clamped circular bimorph piezoelectric micromachined ultrasonic transducer (pMUT) was developed for the first time. The pMUT consisted of two piezoelectric layers sandwiched between three thin electrodes. The top and bottom electrodes were separated into central and annular electrodes by a small gap. While the middle electrode was grounded, the central and annular electrodes were biased with two independent voltage sources. The strain mismatch between the piezoelectric layers caused the plate to vibrate and transmit a pressure wave, whereas the received echo generated electric charges resulting from plate deformation. The clamped pMUT plate was separated into a circular and an annular plate, and the respective electromechanical transformation matrices were derived. The force and velocity vectors were properly selected using Hamilton's principle and the necessary boundary conditions were invoked. The electromechanical transformation matrix for the clamped circular pMUT was deduced using simple matrix manipulation techniques. The pMUT performance under three biasing schemes was elaborated: 1) central electrode only, 2) central and annular electrodes with voltages of the same magnitude and polarity, and 3) central and annular electrodes with voltages of the same magnitude and opposite polarity. The circuit parameters of the pMUT were extracted for each biasing scheme, including the transformer ratio, the clamped electric impedance, and the open-circuit mechanical impedance. Each pMUT scheme was characterized under different acoustic loadings using the theoretically developed model, which was verified with finite element modeling (FEM) simulation. The electrode size was optimized to maximize the electromechanical transformer ratio. As such, the developed model could provide more insight into the design, optimization, and characterization of pMUTs and allow for performance comparison with their cMUT counterparts.

  18. Automation and robotics for the Space Station - The influence of the Advanced Technology Advisory Committee

    Science.gov (United States)

    Nunamaker, Robert R.; Willshire, Kelli F.

    1988-01-01

    The reports of a committee established by Congress to identify specific systems of the Space Station which would advance automation and robotics technologies are reviewed. The history of the committee, its relation to NASA, and the reports which it has released are discussed. The committee's reports recommend the widespread use of automation and robotics for the Space Station, a program for technology development and transfer between industries and research and development communities, and the planned use of robots to service and repair satellites and their payloads which are accessible from the Space Station.

  19. The training and assessment of operations engineers at Hinkley Point 'B' nuclear power station

    International Nuclear Information System (INIS)

    Walsey, B.A.; Howard, J.D.

    1986-01-01

    The Nuclear Power Training Centre at Oldbury-on-Severn was established to provide a common training of staff at all nuclear power stations operated by the Central Electricity Generating Board, following the ''Standard Specification for the Nuclear Training of Staff at CEGB Nuclear Power Stations''. The paper deals with the following aspects of AGR Stations: The Legislation applicable to these stations. The current training requirements for Operations Staff. The development of training for operations staff at Hinkley Point 'B' including training for career progression within the Operations Department. A detailed explanation of the training package developed for Reactor Desk Drivers at Hinkley 'B'. Revision training of Operations staff to ensure that they continue to run the plant in a safe and commercially viable manner. The training of Shift Operations Engineers for their duties under the Station Emergency Plan. (author)

  20. Single stage buck-boost DC-AC neutral point clamped inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Andrew, A.

    2012-01-01

    This paper proposes a new single stage buck-boost DC-AC neutral point clamped inverter topology which integrates the cascaded configurations of recently introduced inductor-capacitor-capacitor-transformer impedance source network (by Adamowicz) and classic NPC configuration. As a consequence......, it has enhanced buck-boost functionality and low output voltage distortions compared to the traditional Z-source inverter; it has continuous input current which reduces the source stress and inverter noise; it also contains two built-in capacitors which can block the DC current in the transformer...... windings thus preventing the core from saturation; lowers the voltage stresses and power losses of inverter switches and reduces the sizes of filtering devices and as well as obtains better output performance compared to the original two-level Z-source inverters. A phase disposition pulse width modulation...

  1. Research on application of knowledge engineering to nuclear power stations

    International Nuclear Information System (INIS)

    Umeda, Takeo; Kiyohashi, Satoshi

    1990-01-01

    Recently, the research on the software and hardware regarding knowledge engineering has been advanced eagerly. Especially the applicability of expert systems is high. When expert systems are introduced into nuclear power stations, it is necessary to make the plan for introduction based on the detailed knowledge on the works in nuclear power stations, and to improve the system repeatedly by adopting the opinion and request of those in charge upon the trial use. Tohoku Electric Power Co. was able to develop the expert system of practically usable scale 'Supporting system for deciding fuel movement procedure'. The survey and analysis of the works in nuclear power stations, the selection of the system to be developed and so on are reported. In No. 1 plant of Onagawa Nuclear Power Station of BWR type, up to 1/3 of the fuel is replaced at the time of the regular inspection. Some fuel must be taken to outside for ensuring the working space. The works of deciding fuel movement procedure, the development of the system and its evaluation are described. (K.I.)

  2. Dynamic assembly of Hda and the sliding clamp in the regulation of replication licensing

    OpenAIRE

    Kim, Jin S.; Nanfara, Michael T.; Chodavarapu, Sundari; Jin, Kyeong S.; Babu, Vignesh?M.?P.; Ghazy, Mohamed A.; Chung, Scisung; Kaguni, Jon M.; Sutton, Mark D.; Cho, Yunje

    2017-01-01

    Abstract Regulatory inactivation of DnaA (RIDA) is one of the major regulatory mechanisms of prokaryotic replication licensing. In RIDA, the Hda?sliding clamp complex loaded onto DNA directly interacts with adenosine triphosphate (ATP)-bound DnaA and stimulates the hydrolysis of ATP to inactivate DnaA. A prediction is that the activity of Hda is tightly controlled to ensure that replication initiation occurs only once per cell cycle. Here, we determined the crystal structure of the Hda?? clam...

  3. Hydrogen Filling Station

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, Robert F; Sabacky, Bruce; Anderson II, Everett B; Haberman, David; Al-Hassin, Mowafak; He, Xiaoming; Morriseau, Brian

    2010-02-24

    Hydrogen is an environmentally attractive transportation fuel that has the potential to displace fossil fuels. The Freedom CAR and Freedom FUEL initiatives emphasize the importance of hydrogen as a future transportation fuel. Presently, Las Vegas has one hydrogen fueling station powered by natural gas. However, the use of traditional sources of energy to produce hydrogen does not maximize the benefit. The hydrogen fueling station developed under this grant used electrolysis units and solar energy to produce hydrogen fuel. Water and electricity are furnished to the unit and the output is hydrogen and oxygen. Three vehicles were converted to utilize the hydrogen produced at the station. The vehicles were all equipped with different types of technologies. The vehicles were used in the day-to-day operation of the Las Vegas Valley Water District and monitoring was performed on efficiency, reliability and maintenance requirements. The research and demonstration utilized for the reconfiguration of these vehicles could lead to new technologies in vehicle development that could make hydrogen-fueled vehicles more cost effective, economical, efficient and more widely used. In order to advance the development of a hydrogen future in Southern Nevada, project partners recognized a need to bring various entities involved in hydrogen development and deployment together as a means of sharing knowledge and eliminating duplication of efforts. A road-mapping session was held in Las Vegas in June 2006. The Nevada State Energy Office, representatives from DOE, DOE contractors and LANL, NETL, NREL were present. Leadership from the National hydrogen Association Board of Directors also attended. As a result of this session, a roadmap for hydrogen development was created. This roadmap has the ability to become a tool for use by other road-mapping efforts in the hydrogen community. It could also become a standard template for other states or even countries to approach planning for a hydrogen

  4. A method to establish seismic noise baselines for automated station assessment

    Science.gov (United States)

    McNamara, D.E.; Hutt, C.R.; Gee, L.S.; Benz, H.M.; Buland, R.P.

    2009-01-01

    We present a method for quantifying station noise baselines and characterizing the spectral shape of out-of-nominal noise sources. Our intent is to automate this method in order to ensure that only the highest-quality data are used in rapid earthquake products at NEIC. In addition, the station noise baselines provide a valuable tool to support the quality control of GSN and ANSS backbone data and metadata. The procedures addressed here are currently in development at the NEIC, and work is underway to understand how quickly changes from nominal can be observed and used within the NEIC processing framework. The spectral methods and software used to compute station baselines and described herein (PQLX) can be useful to both permanent and portable seismic stations operators. Applications include: general seismic station and data quality control (QC), evaluation of instrument responses, assessment of near real-time communication system performance, characterization of site cultural noise conditions, and evaluation of sensor vault design, as well as assessment of gross network capabilities (McNamara et al. 2005). Future PQLX development plans include incorporating station baselines for automated QC methods and automating station status report generation and notification based on user-defined QC parameters. The PQLX software is available through the USGS (http://earthquake. usgs.gov/research/software/pqlx.php) and IRIS (http://www.iris.edu/software/ pqlx/).

  5. Insulin resistance in patients with type 1 diabetes assessed by glucose clamp studies: systematic review and meta-analysis

    NARCIS (Netherlands)

    Donga, Esther; Dekkers, Olaf M.; Corssmit, Eleonora P. M.; Romijn, Johannes A.

    2015-01-01

    Objective: The aim of this study was to perform a systematic review and meta-analysis on insulin resistance in adult patients with type 1 diabetes mellitus compared to healthy controls, assessed by hyperinsulinemic euglycemic clamp studies. Design and methods: We conducted a systematic search of

  6. Tampa Electric Company Polk Power Station IGCC project: Project status

    Energy Technology Data Exchange (ETDEWEB)

    McDaniel, J.E.; Carlson, M.R.; Hurd, R.; Pless, D.E.; Grant, M.D. [Tampa Electric Co., FL (United States)

    1997-12-31

    The Tampa Electric Company Polk Power Station is a nominal 250 MW (net) Integrated Gasification Combined Cycle (IGCC) power plant located to the southeast of Tampa, Florida in Polk County, Florida. This project is being partially funded under the Department of Energy`s Clean Coal Technology Program pursuant to a Round II award. The Polk Power Station uses oxygen-blown, entrained-flow IGCC technology licensed from Texaco Development Corporation to demonstrate significant reductions of SO{sub 2} and NO{sub x} emissions when compared to existing and future conventional coal-fired power plants. In addition, this project demonstrates the technical feasibility of commercial scale IGCC and Hot Gas Clean Up (HGCU) technology. The Polk Power Station achieved ``first fire`` of the gasification system on schedule in mid-July, 1996. Since that time, significant advances have occurred in the operation of the entire IGCC train. This paper addresses the operating experiences which occurred in the start-up and shakedown phase of the plant. Also, with the plant being declared in commercial operation as of September 30, 1996, the paper discusses the challenges encountered in the early phases of commercial operation. Finally, the future plans for improving the reliability and efficiency of the Unit in the first quarter of 1997 and beyond, as well as plans for future alternate fuel test burns, are detailed. The presentation features an up-to-the-minute update on actual performance parameters achieved by the Polk Power Station. These parameters include overall Unit capacity, heat rate, and availability. In addition, the current status of the start-up activities for the HGCU portion of the plant is discussed.

  7. An In Vivo Study of Low-Dose Intra-Articular Tranexamic Acid Application with Prolonged Clamping Drain Method in Total Knee Replacement: Clinical Efficacy and Safety

    Directory of Open Access Journals (Sweden)

    Paphon Sa-ngasoongsong

    2015-01-01

    Full Text Available Background. Recently, combined intra-articular tranexamic acid (IA-TXA injection with clamping drain method showed efficacy for blood loss and transfusion reduction in total knee replacement (TKR. However, until now, none of previous studies revealed the effect of this technique on pharmacokinetics, coagulation, and fibrinolysis. Materials and Methods. An experimental study was conducted, during 2011-2012, in 30 patients undergoing unilateral TKR. Patients received IA-TXA application and then were allocated into six groups regarding clamping drain duration (2-, 4-, 6-, 8-, 10-, and 12-hours. Blood and drainage fluid were collected to measure tranexamic acid (TXA level and related coagulation and fibrinolytic markers. Postoperative complication was followed for one year. Results. There was no significant difference of serum TXA level at 2 hour and 24 hour among groups (p<0.05. Serum TXA level at time of clamp release was significantly different among groups with the highest level at 2 hour (p<0.0001. There was no significant difference of TXA level in drainage fluid, postoperative blood loss, blood transfusion, and postoperative complications (p<0.05.  Conclusions. Low-dose IA-TXA application in TKR with prolonged clamping drain method is a safe and effective blood conservative technique with only minimal systemic absorption and without significant increase in systemic absorption over time.

  8. Stage measurement at gaging stations

    Science.gov (United States)

    Sauer, Vernon B.; Turnipseed, D. Phil

    2010-01-01

    Stream and reservoir stage are critical parameters in the computation of stream discharge and reservoir volume, respectively. In addition, a record of stream stage is useful in the design of structures that may be affected by stream elevation, as well as for the planning for various uses of flood plains. This report describes equipment and methodology for the observation, sensing, and recording of stage in streams and reservoirs. Although the U.S. Geological Survey (USGS) still uses the traditional, basic stilling-well float system as a predominant gaging station, modern electronic stage sensors and water-level recorders are now commonly used. Bubble gages coupled with nonsubmersible pressure transducers eliminate the need for stilling wells. Submersible pressure transducers have become common in use for the measurement of stage in both rivers and lakes. Furthermore, noncontact methods, such as radar, acoustic, and laser methods of sensing water levels, are being developed and tested, and in the case of radar, are commonly used for the measurement of stage. This report describes commonly used gaging-station structures, as well as the design and operation of gaging stations. Almost all of the equipment and instruments described in this report will meet the accuracy standard set by the USGS Office of Surface Water (OSW) for the measurement of stage for most applications, which is ±0.01 foot (ft) or 0.2 percent of the effective stage. Several telemetry systems are used to transmit stage data from the gaging station to the office, although satellite telemetry has become the standard. These telemetry systems provide near real-time stage data, as well as other information that alerts the hydrographer to extreme or abnormal events, and instrument malfunctions.

  9. The Space Station Freedom - International cooperation and innovation in space safety

    Science.gov (United States)

    Rodney, George A.

    1989-01-01

    The Space Station Freedom (SSF) being developed by the United States, European Space Agency (ESA), Japan, and Canada poses novel safety challenges in design, operations, logistics, and program management. A brief overview discloses many features that make SSF a radical departure from earlier low earth orbit (LEO) space stations relative to safety management: size and power levels; multiphase manned assembly; 30-year planned lifetime, with embedded 'hooks and scars' forevolution; crew size and skill-mix variability; sustained logistical dependence; use of man, robotics and telepresence for on-orbit maintenance of station and free-flyer systems; closed-environment recycling; use of automation and expert systems; long-term operation of collocated life-sciences and materials-science experiments, requiring control and segregation of hazardous and chemically incompatible materials; and materials aging in space.

  10. The International Space Station: A Pathway to the Future

    Science.gov (United States)

    Kitmacher, Gary H.; Gerstenmaier, William H.; Bartoe, John-David F.; Mustachio, Nicholas

    2004-01-01

    Nearly six years after the launch of the first International Space Station element, and four years after its initial occupation, the United States and our 16 international partners have made great strides in operating this impressive Earth orbiting research facility. This past year we have done so in the face of the adversity of operating without the benefit of the Space Shuttle. In his January 14, 2004, speech announcing a new vision for America's space program, President Bush affirmed the United States' commitment to completing construction of the International Space Station by 2010. The President also stated that we would focus our future research aboard the Station on the longterm effects of space travel on human biology. This research will help enable human crews to venture through the vast voids of space for months at a time. In addition, ISS affords a unique opportunity to serve as an engineering test bed for hardware and operations critical to the exploration tasks. NASA looks forward to working with our partners on International Space Station research that will help open up new pathways for future exploration and discovery beyond low Earth orbit. This paper provides an overview of the International Space Station Program focusing on a review of the events of the past year, as well as plans for next year and the future.

  11. Energy-Aware Base Stations: The Effect of Planning, Management, and Femto Layers

    Directory of Open Access Journals (Sweden)

    G. Koutitas

    2014-01-01

    Full Text Available We compare the performance of three base station management schemes on three different network topologies. In addition, we explore the effect of offloading traffic to heterogeneous femtocell layer upon energy savings taking into account the increase of base station switch-off time intervals. Fairness between mobile operator and femtocell owners is maintained since current femtocell technologies present flat power consumption curves with respect to served traffic. We model two different user-to-femtocell association rules in order to capture realistic and maximum gains from the heterogeneous network. To provide accurate findings and a holistic overview of the techniques, we explore a real urban district where channel estimations and power control are modeled using deterministic algorithms. Finally, we explore energy efficiency metrics that capture savings in the mobile network operator, the required watts per user and watts per bitrate. It is found that the newly established pseudo distributed management scheme is the most preferable solution for practical implementations and together with the femotcell layer the network can handle dynamic load control that is regarded as the basic element of future demand response programs.

  12. Dynamic Domains in Data Production Planning

    Science.gov (United States)

    Golden, Keith; Pang, Wanlin

    2005-01-01

    This paper discusses a planner-based approach to automating data production tasks, such as producing fire forecasts from satellite imagery and weather station data. Since the set of available data products is large, dynamic and mostly unknown, planning techniques developed for closed worlds are unsuitable. We discuss a number of techniques we have developed to cope with data production domains, including a novel constraint propagation algorithm based on planning graphs and a constraint-based approach to interleaved planning, sensing and execution.

  13. Scanning electron microscope/energy dispersive x ray analysis of impact residues in LDEF tray clamps

    Science.gov (United States)

    Bernhard, Ronald P.; Durin, Christian; Zolensky, Michael E.

    1993-01-01

    Detailed optical scanning of tray clamps is being conducted in the Facility for the Optical Inspection of Large Surfaces at JSC to locate and document impacts as small as 40 microns in diameter. Residues from selected impacts are then being characterized by Scanning Electron Microscopy/Energy Dispersive X-ray Analysis at CNES. Results from this analysis will be the initial step to classifying projectile residues into specific sources.

  14. Effect of shear strain on the deflection of a clamped magnetostrictive film-substrate system

    International Nuclear Information System (INIS)

    Ming Zhenghui; Ming Li; Bo Zou; Xia Luo

    2011-01-01

    The effect of in-plane shear strain of a clamped bimorph on the deflection produced by magnetization of the film is investigated. The deflection is found by minimizing the Gibbs free energy with respect to four parameters, strains and curvatures along x and y directions at the interface, by assuming that the curvature in the y direction varies as a function of aspect ratio w/l along x. A set of standard linear equations of four parameters are obtained and the deflection is expressed in terms of the four parameters by solving the equations using Cramer rules. The inconsistencies pointed out by previous authors are also reviewed. For actuators made of thick and short clamped film-substrate system, the in-plane shear deformation should not be omitted. The present calculation model can give a relatively simple and accurate prediction of deflection for thick and short specimens of aspect ratio w/l<10, which supports the results obtained by finite element modeling. - Highlights: → We model the deflection of a thick magnetostrictive film-substrate cantilever plate. → Total stress along z from magnetic field is not zero without external force. → Effect of in-plane shear strain in calculating deflection examined. → Analytical solution of deflection obtained by assuming a curvature function. → Shear strain for short cantilever film-substrate plate considered.

  15. Influence of squeeze film damping on the higher-order modes of clamped–clamped microbeams

    KAUST Repository

    Alcheikh, Nouha

    2016-05-06

    This paper presents an experimental study and a finite-element analysis of the effect of squeeze film damping on the resonance frequency and quality factor of the higher-order flexure vibrations modes of clamped-clamped microbeams. Viscoelastic and silicon nitride microbeams are fabricated and are electrostatically actuated by various electrode configurations to trigger the first, second, and third modes. The damping characteristic and the resonance frequency of these modes are examined for a wide range of gas pressure and electrostatic voltage loads. The results of the silicon nitride beams and viscoelastic beams are compared. It is found that the intrinsic material loss is the major dissipation mechanism at low pressure for the viscoelastic microbeams, significantly limiting their quality factor. It is also found that while the silicon nitride beams show higher quality factors at the intrinsic and molecular regimes of pressure, due to their low intrinsic loss, their quality factors near atmospheric pressure are lower than those of the viscoelastic microbeams. Further, the higher-order modes of all the beams show much higher quality factors at atmospheric pressure compared to the first mode, which could be promising for operating such resonators in air. Experimental results and finite element model simulations show good agreement for resonance frequency and quality factor for the three studied modes. © 2016 IOP Publishing Ltd.

  16. Large Deployable Reflector (LDR) system concept and technology definition study. Analysis of space station requirements for LDR

    Science.gov (United States)

    Agnew, Donald L.; Vinkey, Victor F.; Runge, Fritz C.

    1989-01-01

    A study was conducted to determine how the Large Deployable Reflector (LDR) might benefit from the use of the space station for assembly, checkout, deployment, servicing, refurbishment, and technology development. Requirements that must be met by the space station to supply benefits for a selected scenario are summarized. Quantitative and qualitative data are supplied. Space station requirements for LDR which may be utilized by other missions are identified. A technology development mission for LDR is outlined and requirements summarized. A preliminary experiment plan is included. Space Station Data Base SAA 0020 and TDM 2411 are updated.

  17. Large Deployable Reflector (LDR) system concept and technology definition study. Analysis of space station requirements for LDR

    Science.gov (United States)

    Agnew, Donald L.; Vinkey, Victor F.; Runge, Fritz C.

    1989-04-01

    A study was conducted to determine how the Large Deployable Reflector (LDR) might benefit from the use of the space station for assembly, checkout, deployment, servicing, refurbishment, and technology development. Requirements that must be met by the space station to supply benefits for a selected scenario are summarized. Quantitative and qualitative data are supplied. Space station requirements for LDR which may be utilized by other missions are identified. A technology development mission for LDR is outlined and requirements summarized. A preliminary experiment plan is included. Space Station Data Base SAA 0020 and TDM 2411 are updated.

  18. The impact of social franchising on the use of reproductive health and family planning services at public commune health stations in Vietnam

    Science.gov (United States)

    2010-01-01

    Background Service franchising is a business model that involves building a network of outlets (franchisees) that are locally owned, but act in coordinated manner with the guidance of a central headquarters (franchisor). The franchisor maintains quality standards, provides managerial training, conducts centralized purchasing and promotes a common brand. Research indicates that franchising private reproductive health and family planning (RHFP) services in developing countries improves quality and utilization. However, there is very little evidence that franchising improves RHFP services delivered through community-based public health clinics. This study evaluates behavioral outcomes associated with a new approach - the Government Social Franchise (GSF) model - developed to improve RHFP service quality and capacity in Vietnam's commune health stations (CHSs). Methods The project involved networking and branding 36 commune health station (CHS) clinics in two central provinces of Da Nang and Khanh Hoa, Vietnam. A quasi-experimental design with 36 control CHSs assessed GSF model effects on client use as measured by: 1) clinic-reported client volume; 2) the proportion of self-reported RHFP service users at participating CHS clinics over the total sample of respondents; and 3) self-reported RHFP service use frequency. Monthly clinic records were analyzed. In addition, household surveys of 1,181 CHS users and potential users were conducted prior to launch and then 6 and 12 months after implementing the GSF network. Regression analyses controlled for baseline differences between intervention and control groups. Results CHS franchise membership was significantly associated with a 40% plus increase in clinic-reported client volumes for both reproductive and general health services. A 45% increase in clinic-reported family planning service clients related to GSF membership was marginally significant (p = 0.05). Self-reported frequency of RHFP service use increased by 20% from

  19. The impact of social franchising on the use of reproductive health and family planning services at public commune health stations in Vietnam

    Directory of Open Access Journals (Sweden)

    Pham Van

    2010-02-01

    Full Text Available Abstract Background Service franchising is a business model that involves building a network of outlets (franchisees that are locally owned, but act in coordinated manner with the guidance of a central headquarters (franchisor. The franchisor maintains quality standards, provides managerial training, conducts centralized purchasing and promotes a common brand. Research indicates that franchising private reproductive health and family planning (RHFP services in developing countries improves quality and utilization. However, there is very little evidence that franchising improves RHFP services delivered through community-based public health clinics. This study evaluates behavioral outcomes associated with a new approach - the Government Social Franchise (GSF model - developed to improve RHFP service quality and capacity in Vietnam's commune health stations (CHSs. Methods The project involved networking and branding 36 commune health station (CHS clinics in two central provinces of Da Nang and Khanh Hoa, Vietnam. A quasi-experimental design with 36 control CHSs assessed GSF model effects on client use as measured by: 1 clinic-reported client volume; 2 the proportion of self-reported RHFP service users at participating CHS clinics over the total sample of respondents; and 3 self-reported RHFP service use frequency. Monthly clinic records were analyzed. In addition, household surveys of 1,181 CHS users and potential users were conducted prior to launch and then 6 and 12 months after implementing the GSF network. Regression analyses controlled for baseline differences between intervention and control groups. Results CHS franchise membership was significantly associated with a 40% plus increase in clinic-reported client volumes for both reproductive and general health services. A 45% increase in clinic-reported family planning service clients related to GSF membership was marginally significant (p = 0.05. Self-reported frequency of RHFP service use

  20. The duty health physicist program at Byron Nuclear Power Station

    International Nuclear Information System (INIS)

    Goldsmith, D.G.; Carey, T.R.

    1987-01-01

    The Duty Health Physicist Program at Byron Station was established to deal with routine health physics tasks and provide an interface between frontline and upper radiation-chemistry management. The program consists of a weekly rotation of selected members of the health physics staff into the duty health physicist position to handle the assigned duty tasks. The tasks include, but are not limited to, daily isotopic and air sample review, effluent release package review, maximum permissible concentration calculations, dose approvals, as-low-as-reasonably-achievable action review of pending jobs, and general availability to answer questions and address problems in health-physics-related areas of plant operation. The daily attendance of the duty health physicist at the radiation-chemistry and station plan-of-the-day meetings has increased the overall presence and visibility of the health physics program to upper station management and other station departments. Since its inception in July of 1985, the Duty Health Physics Program has been a major contributor to the observed 50% reduction in reportable personnel errors in the radiation-chemistry department (based on personnel-error-related deviation reports and license event reports generated on the radiation-chemistry department at Byron Station). Although difficulty to quantify, other important benefits of this program are also discussed in this paper