WorldWideScience

Sample records for pixe analysis electrostatic

  1. Possibility of analysis using RBS, PIXE and nuclear reaction on the electrostatic Pelletron accelerator 5SDH-2

    International Nuclear Information System (INIS)

    Nguyen The Nghia; Bui Van Loat; Le Hong Khiem

    2011-01-01

    The electrostatic Pelletron accelerator 5SDH-2 is installing at Hanoi University of Sciences. This accelerator will be the first tandem electrostatic accelerator installed in Vietnam. The schematic structure, principle of operation of the machine and its application for analysis using Rutherford Back Scattering (RBS), Particle-Induced X-ray Emission (PIXE) and Nuclear Reaction Analysis (NRA) will be presented. (author)

  2. Fundamentals of PIXE analysis

    International Nuclear Information System (INIS)

    Ishii, Keizo

    1997-01-01

    Elemental analysis based on the particle induced x-ray emission (PIXE) is a novel technique to analyze trace elements. It is a very simple method, its sensitivity is very high, multiple elements in a sample can be simultaneously analyzed and a few 10 μg of a sample is enough to be analyzed. Owing to these characteristics, the PIXE analysis is now used in many fields (e.g. biology, medicine, dentistry, environmental pollution, archaeology, culture assets etc.). Fundamentals of the PIXE analysis are described here: the production of characteristic x-rays and inner shell ionization by heavy charged particles, the continuous background in PIXE spectrum, quantitative formulae of the PIXE analysis, the detection limit of PIXE analysis, etc. (author)

  3. PIXE analysis of thin samples

    International Nuclear Information System (INIS)

    Kiss, Ildiko; Koltay, Ede; Szabo, Gyula; Laszlo, S.; Meszaros, A.

    1985-01-01

    Particle-induced X-ray emission (PIXE) multielemental analysis of thin film samples are reported. Calibration methods of K and L X-lines are discussed. Application of PIXE analysis to aerosol monitoring, multielement aerosol analysis is described. Results of PIXE analysis of samples from two locations in Hungary are compared with the results of aerosol samples from Scandinavia and the USA. (D.Gy.)

  4. Hair analysis using PIXE

    International Nuclear Information System (INIS)

    Li Hongkou.

    1983-10-01

    A simple new technique for examining single hair strands to obtain linear mass densities, longitudinal profiles and transverse distribution of each trace element is described. It is primarily based upon the PIXE technique, in combination with proton back- scattering. The three main components of this technique are: 1) An accurate way of using an interpolation method to evaluate the magnitude of the correction factor accounting for the proton energy loss and X-ray absorption in the bulk of the hair is formulated; 2) A simple method to qualitatively determine the transverse distribution of each trace element in a hair is in- troduced and proved to be effective; 3) Proton back-scattering is proved to be capable of providing an ideal linear measure of the geometric hair diameter, one of the most important parameters in quantifying the results of PIXE measurements in mass concentrations. Using the technique, a PIXE system designed and constructed for routine longitudinal scanning of single hair strands is also described. (Author)

  5. PIXE analysis by baby cyclotron

    International Nuclear Information System (INIS)

    Yoshida, Hyogo; Tanaka, Teruaki; Ito, Takashi; Toda, Yohjiro; Wakasa, Hideichiro

    1988-01-01

    The Japan Steel Works, Ltd. has been supplying a very small sized cyclotron (Baby Cyclotron) to hospitals and research facilities. The cyclotron is designed to produce short-lived radioisotopes for medical use. In the present study, this cyclotron is modified so that it can serve for PIXE analysis. The PIXE (particle induced X-ray emission) technique has the following features: (1) Down to 1 ng of trace material in a sample (mg - μg) can be detected, (2) An analysis run is completed in one to ten minutes, permitting economical analysis for a large number of samples, (3) Several elements can be analyzed simultaneously, with an almost constant sensitivity for a variety of elements ranging from aluminum to heavy metals, (4) Analysis can be performed nondestructively without a chemical process, and (5) The use of microbeam can provide data on the distribution of elements with a resolution of several μm. Software for analysis is developed to allow the modified equipment to perform peak search, background fitting, and identification and determination of peaks. A study is now being conducted to examine the performance of the equipment for PIXE analysis of thin samples. Satisfactory results have been obtained. The analysis time, excluding the background correction, is 5-10 min. (Nogami, K.)

  6. Network application of PIXE trace element analysis

    International Nuclear Information System (INIS)

    Niizeki, T.; Kawasaki, K.; Hattori, T.

    2003-01-01

    Particle Induced X-ray Emission (PIXE) is a very sensitive analytical technique for determinations of trace elements. But the number of users is limited because there are not so much accelerators which can be used easily. On the other hand, PIXE is a typical machine analysis which can easily analyze automatically and make online data acquisition system. If there is useful online data handling system then PIXE analysis should be more useful for many persons. Therefore we develop to online PIXE facility at Tokyo Institute of Technology VdG laboratory and use it for environmental educations. (author)

  7. Uncertainties in thick-target PIXE analysis

    International Nuclear Information System (INIS)

    Campbell, J.L.; Cookson, J.A.; Paul, H.

    1983-01-01

    Thick-target PIXE analysis insolves uncertainties arising from the calculation of thick-target X-ray production in addition to the usual PIXE uncertainties. The calculation demands knowledge of ionization cross-sections, stopping powers and photon attenuation coefficients. Information on these is reviewed critically and a computational method is used to estimate the uncertainties transmitted from this data base into results of thick-target PIXE analyses with reference to particular specimen types using beams of 2-3 MeV protons. A detailed assessment of the accuracy of thick-target PIXE is presented. (orig.)

  8. Turbo Pascal Computer Code for PIXE Analysis

    International Nuclear Information System (INIS)

    Darsono

    2002-01-01

    To optimal utilization of the 150 kV ion accelerator facilities and to govern the analysis technique using ion accelerator, the research and development of low energy PIXE technology has been done. The R and D for hardware of the low energy PIXE installation in P3TM have been carried on since year 2000. To support the R and D of PIXE accelerator facilities in harmonize with the R and D of the PIXE hardware, the development of PIXE software for analysis is also needed. The development of database of PIXE software for analysis using turbo Pascal computer code is reported in this paper. This computer code computes the ionization cross-section, the fluorescence yield, and the stopping power of elements also it computes the coefficient attenuation of X- rays energy. The computer code is named PIXEDASIS and it is part of big computer code planed for PIXE analysis that will be constructed in the near future. PIXEDASIS is designed to be communicative with the user. It has the input from the keyboard. The output shows in the PC monitor, which also can be printed. The performance test of the PIXEDASIS shows that it can be operated well and it can provide data agreement with data form other literatures. (author)

  9. Pittsburgh rainwater analysis by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K C; Cohen, B L; Frohliger, J O; Shabason, L

    1976-01-01

    Concentrations of thirteen elements in rainwater from the Pittsburgh, Pa., area were analysed by Charged Particle Induced X-ray Emission (PIXE). They were compared to rainwater in a rural area and air particulates in Pittsburgh. Local and non-local contributions are discussed. Washout ratios were calculated and found to be larger for smaller size particles, contrary to general belief. The work demonstrates the convenience of using PIXE.

  10. PIXE Analysis of Artificial Turf

    Science.gov (United States)

    Conlan, Skye; Chalise, Sajju; Porat, Zachary; Labrake, Scott; Vineyard, Michael

    2017-09-01

    In recent years, there has been debate regarding the use of the crumb rubber infill in artificial turf on high school and college campuses due to the potential presence of heavy metals and carcinogenic chemicals. We performed Proton-Induced X-Ray Emission (PIXE) analysis of artificial turf infill and blade samples collected from high school and college campuses around the Capital District of NYS to search for potentially toxic substances. Crumb rubber pellets were made by mixing 1g of rubber infill and 1g of epoxy. The pellets and the turf blades were bombarded with 2.2 MeV proton beams from a 1.1-MV tandem Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory and x-ray energy spectra were collected with an Amptek silicon drift detector. We analyzed the spectra using GUPIX software to determine the elemental concentrations of the samples. The turf infill showed significant levels of Ti, Fe, Co, Ni, Cu, Zn, Br, and Pb. The highest concentration of Br in the crumb rubber was 1500 +/-100 ppm while the highest detectable amount of Pb concentration was 110 +/-20 ppm. The artificial turf blades showed significant levels of Ti, Fe, and Zn with only the yellow blade showing concentrations of V and Bi.

  11. Analysis of iron gall inks by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Budnar, Milos [Jozef Stefan Institute, Jamova 39, p.p. 3000, SI-1001 Ljubljana (Slovenia)]. E-mail: milos.budnar@ijs.si; Ursic, Mitja [Jozef Stefan Institute, Jamova 39, p.p. 3000, SI-1001 Ljubljana (Slovenia); Simcic, Jure [Jozef Stefan Institute, Jamova 39, p.p. 3000, SI-1001 Ljubljana (Slovenia); Pelicon, Primoz [Jozef Stefan Institute, Jamova 39, p.p. 3000, SI-1001 Ljubljana (Slovenia); Kolar, Jana [National University Library, Turjaska 1, SI-1000 Ljubljana (Slovenia); Selih, Vid Simon [University of Ljubljana, Faculty of Chemistry and Chemical Technology, Askerceva 5, SI-1000 Ljubljana (Slovenia); Strlic, Matija [University of Ljubljana, Faculty of Chemistry and Chemical Technology, Askerceva 5, SI-1000 Ljubljana (Slovenia)

    2006-02-15

    Micro- or non-destructive analytical approach is an imperative when analysing historical artefacts. Due to its practically non-destructive character, proton induced X-ray spectrometry (PIXE) has become a method of choice for the study of historical documents. In the present paper, use of in-air PIXE method for analysis of iron gall inks applied at handwriting of documents is evaluated. The errors arising from the non-uniform ink deposit, proton penetration depth and size of the proton beam versus width of ink lines, effects of surface roughness, as well as the importance of the PIXE set-up geometry on the accuracy of the results are discussed. It follows that the main problems can be attributed to the fact that PIXE is a surface technique and that the analysis is limited to a small amount of material, while ink deposit on the paper is usually non-uniform in depth as well as on the paper surface. Despite possible systematic uncertainties when applying the PIXE method, good correlation between determinations obtained by PIXE and atomic absorption spectroscopy (AAS) on model samples clearly demonstrate that the errors are well within a reasonable limit of a few percents.

  12. Analysis of iron gall inks by PIXE

    International Nuclear Information System (INIS)

    Budnar, Milos; Ursic, Mitja; Simcic, Jure; Pelicon, Primoz; Kolar, Jana; Selih, Vid Simon; Strlic, Matija

    2006-01-01

    Micro- or non-destructive analytical approach is an imperative when analysing historical artefacts. Due to its practically non-destructive character, proton induced X-ray spectrometry (PIXE) has become a method of choice for the study of historical documents. In the present paper, use of in-air PIXE method for analysis of iron gall inks applied at handwriting of documents is evaluated. The errors arising from the non-uniform ink deposit, proton penetration depth and size of the proton beam versus width of ink lines, effects of surface roughness, as well as the importance of the PIXE set-up geometry on the accuracy of the results are discussed. It follows that the main problems can be attributed to the fact that PIXE is a surface technique and that the analysis is limited to a small amount of material, while ink deposit on the paper is usually non-uniform in depth as well as on the paper surface. Despite possible systematic uncertainties when applying the PIXE method, good correlation between determinations obtained by PIXE and atomic absorption spectroscopy (AAS) on model samples clearly demonstrate that the errors are well within a reasonable limit of a few percents

  13. Micro-PIXE for single cell analysis

    International Nuclear Information System (INIS)

    Ortega, Richard

    2012-01-01

    The knowledge of the intracellular distribution of biological relevant metals is important to understand their mechanisms of action in cells, either for physiological, toxicological or pathological processes. However, the direct detection of trace metals in single cells is a challenging task that requires sophisticated analytical developments. The combination of micro-PIXE with RBS and STIM (Scanning Transmission Ion Microscopy) allows the quantitative determination of trace metal content within sub-cellular compartments. The application of STIM analysis provides high spatial resolution imaging (< 200 nm) and excellent mass sensitivity (< 0.1 ng). Application of the STIM-PIXE-RBS methodology is absolutely needed when organic mass loss appears during PIXE-RBS irradiation. This combination of STIM-PIXE-RBS provides fully quantitative determination of trace element content, expressed in μg/g, which is a quite unique capability for micro-PIXE compared to other micro-analytical methods such as the electron and synchrotron x-ray fluorescence. Examples of micro-PIXE studies for sub-cellular imaging of trace elements in various fields of interest will be presented: in patho-physiology of trace elements involved in neurodegenerative diseases such as Parkinson's disease, and in toxicology of metals such as cobalt. (author)

  14. PIXE methodology of rare earth element analysis and its applications

    International Nuclear Information System (INIS)

    Ma Xinpei

    1992-01-01

    The Proton Induced X-ray Emission (PIXE) methodology of rare earth element (REEs) analysis is discussed, including the significance of REE analysis, the principle of PIXE applied to REE, selection of characteristic X-ray for Lanthanide series elements, deconvolution of highly over lapped PIXE spectrum and minimum detection limit (MDL) of REEs. Some practical applications are presented. And the specialities of PIXE analysis to the high pure REE chemicals are discussed. (author)

  15. PIXE analysis of Zn enzymes

    International Nuclear Information System (INIS)

    Solis, C.; Oliver, A.; Andrade, E.; Ruvalcaba-Sil, J.L.; Romero, I.; Celis, H.

    1999-01-01

    Zinc is a necessary component in the action and structural stability of many enzymes. Some of them are well characterized, but in others, Zn stoichiometry and its association is not known. PIXE has been proven to be a suitable technique for analyzing metallic proteins embedded in electrophoresis gels. In this study, PIXE has been used to investigate the Zn content of enzymes that are known to carry Zn atoms. These include the carbonic anhydrase, an enzyme well characterized by other methods and the cytoplasmic pyrophosphatase of Rhodospirillum rubrum that is known to require Zn to be stable but not how many metal ions are involved or how they are bound to the enzyme. Native proteins have been purified by polyacrylamide gel electrophoresis and direct identification and quantification of Zn in the gel bands was performed with an external proton beam of 3.7 MeV energy

  16. Grazing-incident PIXE Analysis Technology

    International Nuclear Information System (INIS)

    Li Hongri; Wang Guangpu; Liang Kun; Yang Ru; Han Dejun

    2009-01-01

    In the article, the grazing incidence technology is first applied to the PIXE (proton induced X-ray emission) analysis. Three pieces of samples were investigated, including the contaminated aluminium substrate, the SIMOX (separated by oxygen implantation) SOI (Silicon on Insulator) sample and the silicon wafer implanted with Fe + . The results reveal that the grazing-incident proton can improve the sensitivity of PIXE in trace analysis, especially for samples contaminated on surface. With the penetration depth of the proton bean decreased, the ratio of the peak area to the detection limit raised observably and the sensitivity near the sample surface increased. (authors)

  17. PIXE analysis of vehicle exhaust particulate

    International Nuclear Information System (INIS)

    Shi Xianfeng; Yao Huiying; Liu Bo; Sun Minde; Xu Huawei; Mi Yong; Shen Hao

    2001-01-01

    PIXE technique on the analysis of vehicle exhaust particulate is introduced. The clement composition and concentration of particulate are obtained. Some elements which are related to environmental pollution such as sulfur lead, silicon and manganese, were analyzed and discussed in detail by PIXE technique Nowadays although unleaded gasoline is widely used, the lead concentration is still very high in exhaust particulate. The concentrations of silicon and manganese in exhaust particulate from different model vehicles are also quite high from measurements. It shows that an evidence for exhaust pollution control could be provided from this work

  18. PIXE analysis of powdered milk

    International Nuclear Information System (INIS)

    Hallak, A.B.

    1983-01-01

    An accelerator-based study, using proton-induced x-ray emission (PIXE) was performed on four full-cream and four half-cream brands of powdered milk commonly consumed in Jordan. The elements detected in the samples are S, Cl, K, Ca, Fe, Cu, Zn, Br and Rb. The significance of some of these elements is discussed from the viewpoint of nutrition and also their effect on milk processing and dairy technology. The standard reference milk sample, A-11, which is distributed by IAEA was also examined, and the results for trace elements detected are compared with the values certified by IAEA. (author)

  19. External beam PIXE analysis of painting

    International Nuclear Information System (INIS)

    Pascholati, Paulo R.; Rizzutto, Marcia A.; Barbosa, Marcel D.L.; Albuquerque, Cindy

    2005-01-01

    The preservation and conservation of mankind cultural heritage has become an important issue worldwide. Non-destructive analytical techniques are suitable, for example, to analyze precious and unique objects of art and archaeology. Among those techniques Particle Induced X-Ray Emission (PIXE) has good advantage to identify elemental composition present in these kinds of objects. The Laboratorio de Analise de Materiais por Feixes Ionicos-LAMFI of the Institute of Physics of the University of Sao Paulo has been installed an external beam facility for PIXE analysis. This new setup is being used for the analysis of archaeological pottery artifacts, paintings and biological tissues (teeth and bones), which are not compatible with the high vacuum of the regular PIXE target chamber. In addition most art and archaeological objects are too large for the evacuated analysis chamber. Applications of this facility will be presented in the analysis of one painting of the beginning of the last century. The chemical elements identified in the painting were Ca, Ti, Cr, Cu, Fe, Zn, Pb and Ba. The PIXE measurements were done non-destructively and no visible damage was observed on the irradiated object. (author)

  20. A forensic application of PIXE analysis

    International Nuclear Information System (INIS)

    Kravchenko, I.I.; Dunnam, F.E.; Rinsvelt, H.A. van; Warren, M.W.; Falsetti, A.B.

    2001-01-01

    PIXE measurements were performed on various calcareous materials including identified bone residues, human cremains, and samples of disputed origin. In a forensic application, the elemental analysis suggests that the origin of a sample suspectly classified as human cremains can tentatively be identified as a mixture of sandy soil and dolomitic limestone

  1. Uncertainties in elemental quantitative analysis by PIXE

    International Nuclear Information System (INIS)

    Montenegro, E.C.; Baptista, G.B.; Paschoa, A.S.; Barros Leite, C.V.

    1979-01-01

    The effects of the degree of non-uniformity of the particle beam, matrix composition and matrix thickness in a quantitative elemental analysis by particle induced X-ray emission (PIXE) are discussed and a criterion to evaluate the resulting degree of uncertainty in the mass determination by this method is established. (Auth.)

  2. Elemental analysis with external-beam PIXE

    Science.gov (United States)

    Lin, E. K.; Wang, C. W.; Teng, P. K.; Huang, Y. M.; Chen, C. Y.

    1992-05-01

    A beamline system and experimental setup has been established for elemental analysis using PIXE with an external beam. Experiments for the study of the elemental composition of ancient Chinese potsherds (the Min and Ching ages) were performed. Continuum X-ray spectra from the samples bombarded by 3 MeV protons have been measured with a Si(Li) detector. From the analysis of PIXE data, the concentration of the main elements (Al, Si, K, and Ca) and of more than ten trace elements in the matrices and glazed surfaces were determined. Results for two different potsherds are presented, and those obtained from the glaze colorants are compared with the results of measurements on a Ching blue-and-white porcelain vase.

  3. Particulate characterization by PIXE multivariate spectral analysis

    International Nuclear Information System (INIS)

    Antolak, Arlyn J.; Morse, Daniel H.; Grant, Patrick G.; Kotula, Paul G.; Doyle, Barney L.; Richardson, Charles B.

    2007-01-01

    Obtaining particulate compositional maps from scanned PIXE (proton-induced X-ray emission) measurements is extremely difficult due to the complexity of analyzing spectroscopic data collected with low signal-to-noise at each scan point (pixel). Multivariate spectral analysis has the potential to analyze such data sets by reducing the PIXE data to a limited number of physically realizable and easily interpretable components (that include both spectral and image information). We have adapted the AXSIA (automated expert spectral image analysis) program, originally developed by Sandia National Laboratories to quantify electron-excited X-ray spectroscopy data, for this purpose. Samples consisting of particulates with known compositions and sizes were loaded onto Mylar and paper filter substrates and analyzed by scanned micro-PIXE. The data sets were processed by AXSIA and the associated principal component spectral data were quantified by converting the weighting images into concentration maps. The results indicate automated, nonbiased, multivariate statistical analysis is useful for converting very large amounts of data into a smaller, more manageable number of compositional components needed for locating individual particles-of-interest on large area collection media

  4. PIXE and XRF Analysis of Roman Denarii

    Science.gov (United States)

    Fasano, Cecilia; Raddell, Mark; Manukyan, Khachatur; Stech, Edward; Wiescher, Michael

    2017-09-01

    A set of Roman Denarii from the republican to the imperial period (140BC-240AD) has been studied using X-ray fluorescent (XRF) scanning and proton induced x-ray emission (PIXE) techniques. XRF and PIXE are commonly used in the study of cultural heritage objects because they are nondestructive. The combination of these two methods is also unique because of the ability to penetrate the sample with a broader spectrum of depths and energies than either could achieve on its own. The coins are from a large span of Roman history and their analysis serves to follow the economic and political change of the era using the relative silver and copper contents in each sample. In addition to analyzing the samples, the study sought to compare these two common analysis techniques and to explore the use of a standard to examine any shortcomings in either of the methods. Data sets were compared and then adjusted to a calibration curve which was created from the analysis of a number of standard solutions. The concentrations of the standard solutions were confirmed using inductively coupled plasma spectroscopy. Through this we were able to assemble results which will progress the basis of understanding of PIXE and XRF techniques as well as increase the wealth of knowledge of Ancient Roman currency.

  5. Elemental analysis of hair using PIXE-tomography and INAA

    International Nuclear Information System (INIS)

    Beasley, D.; Gomez-Morilla, I.; Spyrou, N.

    2008-01-01

    3D quantitative elemental maps of a section of a strand of hair were produced using a combination of PIXE-Tomography and simultaneous On/Off Axis STIM-Tomography at the University of Surrey Ion Beam Centre. The distributions of S, K, Cl, Ca, Fe and Zn were determined using the PIXE-T reconstruction package DISRA. The results were compared with conventional bulk PIXE analysis of tomographic data as determined using Dan32. The overall concentrations determined by PIXE were compared with elemental concentrations held in the University of Surrey Hair Database. All the entries currently in the database were produced using INAA. The merits and possible contributions of tomographic PIXE analysis to analysis of hair are discussed. The conclusions drawn from the PIXE-Tomography analysis can be used to argue for more stringent procedures for hair analysis at the University of Surrey. (author)

  6. Characterisation of candidate reference materials by PIXE analysis and nuclear microprobe PIXE imaging

    International Nuclear Information System (INIS)

    Jaksic, M.; Pastuovic, Z.; Bogdanovic, I.; Tadic, T.

    2002-01-01

    In order to test whether some candidate reference materials show homogeneity that can satisfy quality control of the PIXE technique, six bottles of each of the two Candidate RM's - Lichen (IAEA 338) and Algae (IAEA 413) were tested. Four different tests were performed. First, two pellets from each bottle were prepared and analysed using broad beam (φ = 5 mm) PIXE. Second and third was analysis of homogeneity using scanning focussed beam at the nuclear microprobe. Scans of 50x50 μm 2 and 240x260 μm 2 were performed. Finally, individual grains with composition differing from the rest of the sample, were analysed using PIXE and RBS. (author)

  7. Prehispanic goldwork technology study by PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, Alessandro, E-mail: alessandro.zucchiatti@uam.es [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, Calle de Faraday 3, Madrid 28049 (Spain); Climent Font, Aurelio [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, Calle de Faraday 3, Madrid 28049 (Spain); Gutierrez Neira, Patricia Carolina; Perea, Alicia [Centro de Ciencias Humanas y Sociales, CSIC, Calle Albasanz 26-28, Madrid 28037 (Spain); Fernandez Esquivel, Patricia [Fundación Museos, Banco Central de Costa Rica, San José (Costa Rica); Rovira Llorens, Salvador [Museo Arqueológico Nacional, Calle Serrano 13, Madrid 28006 (Spain); Ruvalcaba Sil, José Luis [Instituto de Física, Universidad Nacional Autónoma de Mexico, Mexici DF 28006 (Mexico); Verde, Ana [Museo de América, Avda. de los Reyes Católicos 6, Madrid 28040 (Spain)

    2014-08-01

    Technological characterization of pre-Hispanic gold metallurgy has still a wide deficit of analytical data. A set of 103 pieces from the so called “Quimbaya’s treasure” (QT) and the “Costa Rica collection” (CRC) of the Museo de America of Madrid were submitted to IBA analysis (PIXE and RBS) at the CMAM in three phases and the metal composition was determined. Only in a limited number of cases, due to the dramatic erosion of the gilded layer, produced by abrasive cleaning methods applied after the discovery and before the seventies, it was possible to determine also the sequence of layers, which gives information on the manufacture technology and the type and purity of the metals. PIXE results are reported and discussed. Data show that the CRC objects have very high gold levels (>80% in weight) while the QT have a more variable composition with significant Cu levels associated to the so called Tumbaga-alloy. In the cases where polishing had a tolerable effect, PIXE (and RBS), point to depletion gilding as a standard finishing process in the Costa Rica production, resulting in a gold rich surface alloy, while the variable composition of the QT objects may well be linked to deliberate colour choice.

  8. Application of PIXE analysis to atmospheric environmental studies

    International Nuclear Information System (INIS)

    Kasahara, Mikio

    1997-01-01

    Physical and chemical properties of the atmospheric aerosols is a fundamental to understand the behavior of aerosols in the atmosphere. The analysis of atmospheric aerosols is the most preferable fields of the PIXE. In this paper, the characteristics of atmospheric aerosols are reviewed at first, and the sampling method of atmospheric aerosols for the PIXE samples and the characterization of atmospheric aerosols using the PIXE analysis are discussed. (author)

  9. PIXE and {mu}-PIXE analysis of glazes from terracotta sculptures of the della Robbia workshop

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, Alessandro E-mail: zucc@ge.infn.it; Bouquillon, Anne; Lanterna, Giancarlo; Franco, Lucarelli; Mando, Pier Andrea; Prati, Paolo; Salomon, Joseph; Vaccari, Maria Grazia

    2002-04-01

    A series of PIXE analyses has been performed on glazes from terracotta sculptures of the Italian Renaissance and on reference standards. The problems related to the investigation of such heterogeneous materials are discussed and the experimental uncertainties are evaluated, for each element, from the PIXE analysis of standard glasses. Some examples from artefacts coming from Italian collections are given. This research has been conducted in the framework of the COST-G1 European action.

  10. PIXE and μ-PIXE analysis of glazes from terracotta sculptures of the della Robbia workshop

    International Nuclear Information System (INIS)

    Zucchiatti, Alessandro; Bouquillon, Anne; Lanterna, Giancarlo; Franco, Lucarelli; Mando, Pier Andrea; Prati, Paolo; Salomon, Joseph; Vaccari, Maria Grazia

    2002-01-01

    A series of PIXE analyses has been performed on glazes from terracotta sculptures of the Italian Renaissance and on reference standards. The problems related to the investigation of such heterogeneous materials are discussed and the experimental uncertainties are evaluated, for each element, from the PIXE analysis of standard glasses. Some examples from artefacts coming from Italian collections are given. This research has been conducted in the framework of the COST-G1 European action

  11. External PIXE analysis of old inks and papers

    International Nuclear Information System (INIS)

    Hassanzadeh, A.; Lamehi-Rachti, M.; Oliaiy, P.; Rahighi, J.; Shokouhi, F.

    1999-01-01

    Proton Induced X-ray Emission, PIXE is a very well established analytical method. This technique of analysis can equally be applied both in vacuum, internal PIXE, and in atmosphere, external PIXE. External PIXE has been applied to material analysis in Van de Graaff laboratory at AEOI using filters and funny filters. Advantages of using these filters have been studied when analysing ancient written documents such as envelopes, inks, and newspapers. This technique clearly demonstrated the differences between new and old inks and papers. More data is needed to show other features of this technique. (author)

  12. PIXE analysis of ancient Jordanian pottery

    International Nuclear Information System (INIS)

    Saleh, N.; Carlsson, L.E.

    1981-01-01

    Proton-induced X-ray emission (PIXE) has been applied for the determination of 18 elements (Si, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Rb, Sr, Y, Zr, Nb, Ba and Pb) in two groups of pottery from two different sites in Jordan, Biblical Bozrah (BB) and Amman Citadel (AC). The analysis showed that the elements Zn, Rb, Sr, Zr and Ba were the most useful elements to study to be able to differentiate between the two groups of pottery. (orig.)

  13. Correction factor for hair analysis by PIXE

    International Nuclear Information System (INIS)

    Montenegro, E.C.; Baptista, G.B.; Castro Faria, L.V. de; Paschoa, A.S.

    1980-01-01

    The application of the Particle Induced X-ray Emission (PIXE) technique to analyse quantitatively the elemental composition of hair specimens brings about some difficulties in the interpretation of the data. The present paper proposes a correction factor to account for the effects of the energy loss of the incident particle with penetration depth, and X-ray self-absorption when a particular geometrical distribution of elements in hair is assumed for calculational purposes. The correction factor has been applied to the analysis of hair contents Zn, Cu and Ca as a function of the energy of the incident particle. (orig.)

  14. PIXE analysis of ancient Chinese Changsha porcelain

    International Nuclear Information System (INIS)

    Lin, E.K.; Yu, Y.C.; Wang, C.W.; Liu, T.Y.; Wu, C.M.; Chen, K.M.; Lin, S.S.

    1999-01-01

    In this work, proton induced X-ray emission (PIXE) method was applied for the analysis of ancient Chinese Changsha porcelain produced in the Tang dynasty (AD 618-907). A collection of glazed potsherds was obtained in the complex of the famous kiln site at Tongguan, Changsha city, Hunan province. Studies of elemental composition were carried out on ten selected Changsha potsherds. Minor and trace elements such as Ti, Mn, Fe, Co, Cu, Rb, Sr, and Zr in the material of the porcelain glaze were determined. Variation of these elements from sample to sample was investigated. Details of results are presented and discussed

  15. Correction factor for hair analysis by PIXE

    International Nuclear Information System (INIS)

    Montenegro, E.C.; Baptista, G.B.; Castro Faria, L.V. de; Paschoa, A.S.

    1979-06-01

    The application of the Particle Induced X-ray Emission (PIXE) technique to analyse quantitatively the elemental composition of hair specimens brings about some difficulties in the interpretation of the data. The present paper proposes a correction factor to account for the effects of energy loss of the incident particle with penetration depth, and x-ray self-absorption when a particular geometrical distribution of elements in hair is assumed for calculational purposes. The correction factor has been applied to the analysis of hair contents Zn, Cu and Ca as a function of the energy of the incident particle.(Author) [pt

  16. PIXE analysis of ancient Chinese Changsha porcelain

    Energy Technology Data Exchange (ETDEWEB)

    Lin, E.K.; Yu, Y.C.; Wang, C.W.; Liu, T.Y.; Wu, C.M.; Chen, K.M.; Lin, S.S

    1999-04-02

    In this work, proton induced X-ray emission (PIXE) method was applied for the analysis of ancient Chinese Changsha porcelain produced in the Tang dynasty (AD 618-907). A collection of glazed potsherds was obtained in the complex of the famous kiln site at Tongguan, Changsha city, Hunan province. Studies of elemental composition were carried out on ten selected Changsha potsherds. Minor and trace elements such as Ti, Mn, Fe, Co, Cu, Rb, Sr, and Zr in the material of the porcelain glaze were determined. Variation of these elements from sample to sample was investigated. Details of results are presented and discussed.

  17. PIXE analysis of ancient Chinese Changsha porcelain

    Science.gov (United States)

    Lin, E. K.; Yu, Y. C.; Wang, C. W.; Liu, T. Y.; Wu, C. M.; Chen, K. M.; Lin, S. S.

    1999-04-01

    In this work, proton induced X-ray emission (PIXE) method was applied for the analysis of ancient Chinese Changsha porcelain produced in the Tang dynasty (AD 618-907). A collection of glazed potsherds was obtained in the complex of the famous kiln site at Tongguan, Changsha city, Hunan province. Studies of elemental composition were carried out on ten selected Changsha potsherds. Minor and trace elements such as Ti, Mn, Fe, Co, Cu, Rb, Sr, and Zr in the material of the porcelain glaze were determined. Variation of these elements from sample to sample was investigated. Details of results are presented and discussed.

  18. PIXE analysis of work environment aerosols

    International Nuclear Information System (INIS)

    Akabayashi, Hideo; Fujimoto, Fuminori; Komaki, Kenichiro; Ootuka, Akio; Kobayashi, Koichi; Yamashita, Hiroshi

    1988-01-01

    In labor environment, the quantity of chemical substances in the air is more, and their kinds are more diversified than in general home environment. It has been well known that some substances contained in the aerosol in labor environment (floating dust in the atmosphere) such as asbestos and hexavalent chromium have the possibility of causing serious injuries such as cancer of respiratory organ. In order to identify the harmful substances to which laborers are exposed and to take the measures for removing them, it is necessary to investigate in detail into many factors related to the effect of aerosol on human bodies, such as the composition of elements, chemical condition, concentration, the particle size of dust and temporal and spatial distributions. For the purpose, sampling and analysis must be carried out so that information can be extracted as much as possible from a minute amount of sample. The particle induced x-ray emission (PIXE) analysis is very effective for this application. In this paper, the development of a PIXE analysis system and the knowledge obtained by the sampling and measurement of aerosol in indoor labor environment are reported. The labor environment selected is that of the workshop of Department of Liberal Arts, University of Tokyo. Sampling, the experimental apparatus, the method of data analysis and the results of analysis are described. (Kako, I.)

  19. System of pattern analysis of PIXE spectra

    Energy Technology Data Exchange (ETDEWEB)

    Murozono, K; Iwasaki, S; Inoue, J; Ishii, K; Kitamura, M [Tohoku Univ., Sendai (Japan). Faculty of Engineering; Sera, K; Futatsugawa, S

    1996-07-01

    We have developed an analysis system based on the pattern analysis method. By testing the system, several difficulties of the present method have been identified. We found the following solutions for them: pre-selection of candidate elements in a sample and the use of a proper absorber. The pre-selection of the candidate elements will not be a serious drawback in the industrial PIXE, because it will be easy to pre-process the spectra for a few samples in the beginning of the mass processing of samples of the same kind. On the other hand, reduction of the efficiency due to the use of funny filter is significant only in the lower energy region, where we usually do not suffer from insufficient yields of lighter elements in common samples. The selection of the most suitable filter requires PIXE user to be deeply experienced. In particular, it is not easy to choose the best filter to suppress the yield of peak of an abundant element as the absorption edge filter. It will be important task to find a set of suitable combination of representative samples and corresponding filters. Furthermore, the peak profile model should be improved from the simple Gaussian approximation to more realistic ones with exponential tail, flat component below the peak and escape peaks, etc. It is also necessary to develop a theoretical approach for the background shape of the bremsstrahlung. (J.P.N.)

  20. PIXE - a new method for elemental analysis

    International Nuclear Information System (INIS)

    Johansson, S.A.E.

    1983-01-01

    With elemental analysis we mean the determination of which chemical elements are present in a sample and of their concentration. This is an old and important problem in chemistry. The earliest methods were purely chemical and many such methods are still used. However, various methods based on physical principles have gradually become more and more important. One such method is neutron activation. When the sample is bombarded with neutrons it becomes radioactive and the various radioactive isotopes produced can be identified by the radiation they emit. From the measured intensity of the radiation one can calculate how much of a certain element that is present in the sample. Another possibility is to study the light emitted when the sample is excited in various ways. A spectroscopic investigation of the light can identify the chemical elements and allows also a determination of their concentration in the sample. In the same way, if a sample can be brought to emit X-rays, this radiation is also characteristic for the elements present and can be used to determine the elemental concentration. One such X-ray method which has been developed recently is PIXE. The name is an acronym for Particle Induced X-ray Emission and indicates the principle of the method. Particles in this context means heavy, charged particles such as protons and a-particles of rather high energy. Hence, in PIXE-analysis the sample is irradiated in the beam of an accelerator and the emitted X-rays are studied. (author)

  1. Analysis of obsidians by PIXE technique

    International Nuclear Information System (INIS)

    Nuncio Q, A.E.

    1998-01-01

    This work presents the characterization of obsydian samples from different mineral sites in Mexico, undertaken by an Ion Beam Analysis: PIXE (Proton Induced X-ray Emission). As part of an intensive investigation of obsidian in Mesoamerica by anthropologists from Mexico National Institute of Anthropology and History, 818 samples were collected from different volcanic sources in central Mexico for the purpose of establishing a data bank of element concentrations of each source. Part of this collection was analyzed by Neutron activation analysis and most of the important elements concentrations reported. In this work, a non-destructive IBA technique (PIXE) are used to analyze obsydian samples. The application of this technique were carried out at laboratories of the ININ Nuclear Center facilities. The samples consisted of of obsydians from ten different volcanic sources. This pieces were mounted on a sample holder designed for the purpose of exposing each sample to the proton beam. This PIXE analysis was carried out with an ET Tandem Accelerator at the ININ. X-ray spectrometry was carried out with an external beam facility employing a Si(Li) detector set at 52.5 degrees in relation to the target normal (parallel to the beam direction) and 4.2 cm away from the target center. A filter was set in front of the detector, to determine the best attenuation conditions to obtain most of the elements, taking into account that X-ray spectra from obsydians are dominated by intense major elements lines. Thus, a 28 μ m- thick aluminium foil absorber was selected and used to reduce the intensity of the major lines as well as pile-up effects. The mean proton energy was 2.62 MeV, and the beam profile was about 4 mm in diameter. As results were founded elemental concentrations of a set of samples from ten different sources: Altotonga (Veracruz), Penjamo (Guanajuato), Otumba (Mexico), Zinapecuaro (Michoacan), Ucareo (Michoacan), Tres Cabezas (Puebla), Sierra Navajas (Hidalgo), Zaragoza

  2. PIXE and ion beam analysis in forensics

    International Nuclear Information System (INIS)

    Bailey, Melanie; Warmenhoven, John; Chrislopher, Matt; Kirkby, Karen; Palitsin, Vladimir; Grime, Geoff; Jeynes, Chris; Jones, Brian; Wenn, Roger

    2013-01-01

    Full text: University of Surrey has, for the past four years, collaborated with police institutions from across Europe and the rest of the world lo scope potential applications of ion beam analysis (IBA) in forensic science. In doing this we have consulted practitioners across a range of forensic disciplines, and critically compared IBA with conventional characterisation techniques to investigate the areas in which IBA can add evidential value. In this talk, the results of this feasibility study will be presented, showing the types of sample for which IBA shows considerable promise. We will show how a combination of PIXE with other IBA techniques (EBS, PIGE, MeV-SIMS) can be used to give unprecedented characterisation of forensic samples and comment on the significance of these results for forensic casework. We will also show cases where IBA not appear to add any significant improvement over conventional techniques. (author)

  3. PIXE analysis of atmospheric particulate matter in glas fibre filters

    International Nuclear Information System (INIS)

    Tabacniks, M.H.; Orsini, C.Q.; Maenhaut, W.

    1993-01-01

    A 3-step extraction procedure was developed to allow particle-induced X-ray emission (PIXE) analysis of particulate matter in normal glass fibre filter samples. The detection limits, expressed in ng/m 3 of air, for the filter extracts were 5 to 30 times lower than those achieved by PIXE analysis or ordinary Nuclepore polycarbonate filter samples. The concentration results were compared with those obtained from routine atomic absorption spectrometry measurements and with the PIXE data from Nuclepore stacked filter unit samples taken in parallel. (orig.)

  4. Fish otoliths analysis by PIXE: application to stock discrimination

    International Nuclear Information System (INIS)

    Arai, Nobuaki; Takai, Noriyuki; Sakamoto, Wataru; Yoshida, Koji; Maeda, Kuniko.

    1996-01-01

    Fish otoliths are continuously deposited from fish birth to its death along with encoding environmental information. In order to decode the information, PIXE was adopted as trace elemental analysis of the otoliths. Strontium to calcium concentration ratios of red sea bream otoliths varied among rearing stations. The Sr/Ca ratios of Lake Biwa catfishes also varied between male and female and among fishing grounds. The PIXE analysis was applied to the fish stock discrimination. (author)

  5. PIXAN: the Lucas Heights PIXE analysis computer package

    International Nuclear Information System (INIS)

    Clayton, E.

    1986-11-01

    To fully utilise the multielement capability and short measurement time of PIXE it is desirable to have an automated computer evaluation of the measured spectra. Because of the complex nature of PIXE spectra, a critical step in the analysis is the data reduction, in which the areas of characteristic peaks in the spectrum are evaluated. In this package the computer program BATTY is presented for such an analysis. The second step is to determine element concentrations, knowing the characteristic peak areas in the spectrum. This requires a knowledge of the expected X-ray yield for that element in the sample. The computer program THICK provides that information for both thick and thin PIXE samples. Together, these programs form the package PIXAN used at Lucas Heights for PIXE analysis

  6. PIXE analysis applied to characterized water samples

    International Nuclear Information System (INIS)

    Santos, Maristela S.; Carneiro, Luana Gomes; Medeiros, Geiza; Sampaio, Camilla; Martorell, Ana Beatriz Targino; Gouvea, Stella; Cunha, Kenya Moore Dias da

    2011-01-01

    Araxa, in Brazil, is a naturally high background area located in the State of Minas Gerais with a population of about 93 672 people. Araxa is historical city famous for its mineral water sources and mud from Termas de Araxa spa, which have been used for therapeutic, and recreation purposes. Other important aspect of economy of the city are mining and metallurgic industries. In the Araxa area is located the largest deposit of pyrochlore, a niobium mineral, and also a deposit of apatite, a phosphate mineral both containing Th and U associated to crystal lattice. The minerals are obtained from open pit mines, the minerals are processed in industrial also located in city of Araxa, these plants process the pyrochlore and apatite to obtain the Fe-Nb alloy and the concentrate of phosphate, respectively. Studies were developed in this area to assessment the occupational risk of the workers due to exposure to dust particles during the routine working, however very few studies evaluated the water contamination outside the mines in order to determine the metal (stables elements) concentrations in water and also the concentrations of the radionuclides in water. This paper presents the previous results of a study to identify and determine the concentrations of metals (stables elements) and radionuclides in river around the city. The water from these rivers is used as drinking water and irrigation water. The water samples were collected in different rivers around the Araxa city and the samples were analyzed using PIXE technique. A proton beam of 2 MeV obtained from the van de Graaff electrostatic accelerator was used to induce the characteristic X-rays. S, K, Ca, Cr, Mn, Fe, Ni, Zn, Ba, Pb and U were identified in the mass spectrum of the samples. The elemental mass concentrations were compared using a non-parametric statistical test. The results of the statistical test showed that the elemental mass concentrations did not present the same distribution. These results indicated

  7. PIXE analysis using external proton beam

    Energy Technology Data Exchange (ETDEWEB)

    Potocek, V; Potockova, J; Dzmuran, R; Sikora, J

    1985-03-01

    The possibilities were studied of the practical use of the analytical PIXE method. Calibration samples were analyzed of Cu, Cd, Hg and Pb in concentrations of 50 to 500 ..mu..g/l as well as natural samples of drinking water, pond water, human blood plasma, dry waste from ground vegetation, mushrooms, pine needles, aerosols, human hair, leaves and flowers, etc. The samples were processed using precipitation, mineralization or incineration and were trapped on a membrane filter (Synpor) or on a Tatrafan ON 15 foil. Some samples were freeze-dried and compressed into pellets. A proton beam with an intensity of 10 to 70 nA was used for analysis and the proton energy was selected 2.2 MeV. For most targets an exposure of 120 s was preset and the measurement lasted at least 60 s and 600 s at the most. It was found that Synpor filters browned and became more brittle during longer exposures. The other targets did not change during analysis.

  8. Elemental PIXE analysis of oolong tea

    International Nuclear Information System (INIS)

    Watanabe, M.; Ishii, K.; Matsuyama, S.

    2008-01-01

    The contamination of heavy metals in food becomes a serious problem. We analyzed oolong tea from different production areas by PIXE using very simple sample preparation and examined trace elements contained in these samples. From the results of this experiment, we could know oolong tea which analyzed in this experiment contains various minerals such as K, Ca, P, S, Cl, Fe, Mn, Cu and Cr but not toxic element of As which detection limit of PIXE was lower than the standard values given by the food hygiene law in Japan. (author)

  9. PIXE - Analysis for environmental and biological samples

    International Nuclear Information System (INIS)

    Baptista, G.B.

    1980-04-01

    The usefulness and accuracy of PIXE as an analytical tool in the study of trace elements in environmental samples of the Brazilian Cerrado are discussed. The report lists actual and forthcoming publications resulting from the study. The mechanism of exchange of elements in solution in water to aerosols has been investigated. For details of the procedure the reader is referred to an earlier report

  10. Parameter determination for quantitative PIXE analysis using genetic algorithms

    International Nuclear Information System (INIS)

    Aspiazu, J.; Belmont-Moreno, E.

    1996-01-01

    For biological and environmental samples, PIXE technique is in particular advantage for elemental analysis, but the quantitative analysis implies accomplishing complex calculations that require the knowledge of more than a dozen parameters. Using a genetic algorithm, the authors give here an account of the procedure to obtain the best values for the parameters necessary to fit the efficiency for a X-ray detector. The values for some variables involved in quantitative PIXE analysis, were manipulated in a similar way as the genetic information is treated in a biological process. The authors carried out the algorithm until they reproduce, within the confidence interval, the elemental concentrations corresponding to a reference material

  11. Development of sample preparation method for honey analysis using PIXE

    International Nuclear Information System (INIS)

    Saitoh, Katsumi; Chiba, Keiko; Sera, Koichiro

    2008-01-01

    We developed an original preparation method for honey samples (samples in paste-like state) specifically designed for PIXE analysis. The results of PIXE analysis of thin targets prepared by adding a standard containing nine elements to honey samples demonstrated that the preparation method bestowed sufficient accuracy on quantitative values. PIXE analysis of 13 kinds of honey was performed, and eight mineral components (Si, P, S, K, Ca, Mn, Cu and Zn) were detected in all honey samples. The principal mineral components were K and Ca, and the quantitative value for K accounted for the majority of the total value for mineral components. K content in honey varies greatly depending on the plant source. Chestnuts had the highest K content. In fact, it was 2-3 times that of Manuka, which is known as a high quality honey. K content of false-acacia, which is produced in the greatest abundance, was 1/20 that of chestnuts. (author)

  12. Calibration of PIXE-SP system of elementary analysis

    International Nuclear Information System (INIS)

    Tabacniks, M.H.

    1983-04-01

    The set-up and calibration of the PIXE-SP System of Elementary Analysis located at the Institute of Physics of the University of Sao Paulo is described. The PIXE-SP, that operates with 8 MeV alpha beam, has been calibrated for elements with Z >= 11, by means of homemade evaporated standard targets of Al, Si, Bacl 2 , K 2 CrO 4 , Ti, Cr, Mn, Fe, Cu, Ge, Ag, Sn, and Au. Those targets are thin, homogeneous, and have been calbrated on a microbalance within an average precision of 6%. The overall precision of the PIXE-SP System is estimated in 10% for elements with 16 2 thick, irradiated with a 10 μC electric charge, shows a minimum of about 0,1 ng (approximated 4 ppm) for Mn. The PIXE-SP System has also been intercalibrated with the PIXE located at University of Gent, Belgium, by means of 12 atmospheric aerosol targets collected on two Batelle Cascade Impactors. The analyzed masses of elements with 16 [pt

  13. Qualitative PIXE analysis of mineral elements in some dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Iordan, Andreea; Harangus, Livia; Ciortea, C.; Gugiu, M.; Moldovan, Maria

    2002-01-01

    Dental composites, made by particles of glass, ceramics and quartz embedded in an organic polymer, develop at a high rate. However, commercial composites are expensive and recently the 'Restacril' biomaterials company became prepared to offer a low-cost alternative. The durability of dental fillings depends not only on biomaterial's gross chemical composition, but also on impurities. These may influence the chemical, mechanical and surface properties of the inorganic particles and modify the composites' clinical behavior. Thus elemental analysis is necessary to improve the biomaterials' quality. Nuclear and atomic methods allow sensitive multielement detection, and we previously analyzed some commercial composites by particle-induced X-ray emission (PIXE). Here we applied PIXE in the qualitative analysis of six new Romanian biomaterials, aiming to compare their nominal and detected composition and paying attention to the impurities. The PIXE measurements were performed with 3 MeV protons at the 8.5 MV NIPNE-HH tandem accelerator, using a hyper pure Ge detector, normal to the beam and connected to a multichannel analyzer and to a computer. Solid samples of composites with a flat surface were fixed at 45 angle, absorber foil of Al 30 mm thick was used, and integration of beam current was done. In all composites PIXE detected mineral elements with Z > 19 down to trace levels. All major nominal elements with Z > 20 - Ca, Sr, Zr, Ba, and Yb - were detected by PIXE. In addition, many minor and trace elements absent from the nominal formulations were seen, including K, Ti, Mn, Fe, Ni, Cu, Zn, Ga, Ag, Cd, Hf, and As/Pb. Such impurities may come from rough materials and preparative technologies. The impurities in Romanian composites are comparable to those in some commercial biomaterials but higher than in other ones. Thus PIXE analysis of mineral elements in Romanian composites, even qualitative, appears useful for quality control and improvement. (authors)

  14. Design and characteristics of a scattering chamber for PIXE analysis

    International Nuclear Information System (INIS)

    Oliver, A.; Miranda, J.; Lopez, K.; Mercado, F.; Flores, A.H.

    1989-01-01

    A scattering chamber for Particle Induced x-ray Emission (PIXE) analysis is described. This chamber was designed and constructed for thin film thickness measurements and depth profiling. The chamber operation characteristics and versatility in materials analysis are shown. (Author). 18 refs, 6 figs

  15. Preliminary report on the PIXE analysis of the squid statoliths

    International Nuclear Information System (INIS)

    Ikeda, Yuzuru; Arai, Nobuaki; Sakamoto, Wataru; Murayama, Tatsuro; Maeda, Kuniko; Yoshida, Koji.

    1996-01-01

    Micro trace elements in the squid statolith, a calcareous stone which acts as a balancer and hearing, was analyzed with Particle Induced X-ray Emission (PIXE) for the Japanese common squid for the first time. Calcium is the main component of the squid statoliths, which means that squid statolith is the pure calcified structure similar to the fish otolith. Beside Ca, Sr was detected with strong dosage, and some other elements as Mn, Fe, Cu, Zn and As were also detected. Possible assumption of intake of microelements to the statoliths and the suitability of PIXE for statoliths analysis are discussed. (author)

  16. PIXE analysis of umeboshi (dried plum)

    International Nuclear Information System (INIS)

    Tsuboi, S.; Ishii, K.; Matsuyama, S.

    2008-01-01

    In recent years, the self-sufficiency ratio of food in Japan has gradually decreased and 60% of foods are now imported from abroad. Japanese people rely strongly upon imported food and should take care of their safety, but what is happening now is that soil pollution in country of origin grows into a serious problem and can affect imported food. Umeboshi is one of the traditional pickled food in Japan and very popular. In the case of umeboshi, more than 65% of it is imported. We analyzed imported umeboshi and domestic ones by using in-air PIXE system and submili-PIXE camera at Tohoku University. In this experiment, the concentrations of toxic heavy metals such as As, Cd, Hg and Pb were lower than standard values given by a food hygiene law. Concentrations of elements heavier than Ca show similar trend among each sample. On the other hand, lighter elements than Ca show large differences, which is related to food coloring or processing technique. (author)

  17. PIXE analysis of caries related trace elements in tooth enamel

    International Nuclear Information System (INIS)

    Annegarn, H.J.; Jodaikin, A.; Cleaton-Jones, P.E.; Sellschop, J.P.F.; Madiba, C.C.P.; Bibby, D.; University of the Witwatersrand, Johannesburg

    1981-01-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis. (orig.)

  18. PIXE analysis of caries related trace elements in tooth enamel

    Energy Technology Data Exchange (ETDEWEB)

    Annegarn, H J; Jodaikin, A; Cleaton-Jones, P E; Sellschop, J P.F.; Madiba, C C.P.; Bibby, D [University of the Witwatersrand, Johannesburg (South Africa). Nuclear Physics Research Unit; University of the Witwatersrand, Johannesburg (South Africa). Dental Research Unit)

    1981-03-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis.

  19. Applicability of PIXE for multielemental analysis in a biomedical application

    International Nuclear Information System (INIS)

    Shakir, N.S.

    1987-07-01

    The applicability of PIXE for multielemental analysis is demonstrated. The method is used in a major systematic study on hair samples using one target analysis. The pathological state considered is agitated elderly people. The main elements examined are S, K, Ca, Fe, Co, Ni, Cu, Zn, Se, Br, Hg and Pb. The minimum detectable limits are 1-10 ppm using 180 μg of dry hair at 25 μe irradiations for elements between K and Br. The significance of differences between the hair elements in control populations and patients suffering from the pathological conditions are investigated. Investigations of possible linear and multiple-correlations between elements in each population are made. The work indicates that some elements do exhibit variation with pathological state, and the multielement PIXE analysis gives useful information about the subject. (author). 13 refs, 4 figs, 6 tabs

  20. Analysis of trace elements in opal using PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Ruth, E-mail: ruth.hinrichs@ufrgs.br [Instituto de Geociências, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Bertol, A.P.L. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Vasconcellos, M.A.Z. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Instituto de Física, UFRGS, Porto Alegre, RS (Brazil)

    2015-11-15

    Particle induced X-ray emission (PIXE) analysis is particularly important for the analysis of trace elements of precious samples, being one of the few methods to determine elements with ppm concentration that does not affect sample integrity. A PIXE methodology for trace element analysis in opal was developed. To avoid detector count saturation due to the high number of Si-Kα X-rays generated in the sample, several filters were employed to optimize the reduction of the Si-Kα signal, while maintaining acceptable intensities of the other relevant X-ray lines. Two proton beam energies were tested, to establish the signal to noise ratio in different X-ray energies. Spectra were fitted with the software GUPIX, using a matrix composition determined with electron beam excited energy dispersive X-ray spectrometry. Above the energy of the silicon X-ray, several trace elements were quantified.

  1. Trace elements in termites by PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, T. E-mail: tsuyoshi@termite.kuwri.kyoto-u.ac.jp; Kagemori, N.; Kawai, S.; Sera, K.; Futatsugawa, S

    2002-04-01

    Trace elements in a Japanese subterranean xylophagous termite, Coptotermes formosanus Shiraki, were analyzed by the PIXE method. The total amount of the 14 predominant elements out of 27 detected in an intact termite was higher in a soldier termite (23 000 {mu}g/g) than in a worker termite (10 000 {mu}g/g). A block of wood (Pinus densiflora Sieb. et Zucc.) for termite feed had a much lower concentration (3600 {mu}g/g) compared with that in an intact termite. This probably relates the functional bio-condensation and/or bio-recycling of trace elements in C. formosanus. When a termite was separated into three anatomical parts, head, degutted body and gut, the worker gut contained the highest total amount of the 14 predominant measured elements (31 000 {mu}g/g). This might be correlated with the higher activity of food digestion and energy production in the worker gut. Moreover, the mandible of the soldier head, with an exoskeleton that is intensely hardened, showed a preferential distribution of Mn and Fe. These results suggest that the characteristic localization of elements will be closely related to the functional role of the individual anatomical part of C. formosanus.

  2. PIXE analysis of atmospheric aerosol and hydrometeor particles

    International Nuclear Information System (INIS)

    Groeneveld, K.O.; Hofmann, D.; Georgii, H.W.

    1993-01-01

    Atmospheric aerosol and hydrometeor particles act decisively on our weather, climate and thereby on all living conditions on Earth. Particle induced X-ray emission (PIXE) analysis has been demonstrated to be an extremely valuable tool for quantitative and qualitative elemental analysis of aerosol particles and hydrometeors. Reliability and detection limits of PIXE are determined, including comparison with other techniques. Aerosol particles are collected on a global scale in ground stations, or by ships and by planes. Correlation between wind direction and elemental composition of atmospheric aerosols, elemental particle size distributions of the tropospheric aerosol, aerosol elemental composition in particle size fractions in the case of long range transport, transport pathways of pollution aerosol, and trace element content precipitation are discussed. Hydrometeors were studied in the form of rain, snow, fog, dew and frost. The time dependence of the melting process of snow was studied in detail, in particular the washout phenomena of impurity ions. (orig.)

  3. PIXE-quantified AXSIA: Elemental mapping by multivariate spectral analysis

    International Nuclear Information System (INIS)

    Doyle, B.L.; Provencio, P.P.; Kotula, P.G.; Antolak, A.J.; Ryan, C.G.; Campbell, J.L.; Barrett, K.

    2006-01-01

    Automated, nonbiased, multivariate statistical analysis techniques are useful for converting very large amounts of data into a smaller, more manageable number of chemical components (spectra and images) that are needed to describe the measurement. We report the first use of the multivariate spectral analysis program AXSIA (Automated eXpert Spectral Image Analysis) developed at Sandia National Laboratories to quantitatively analyze micro-PIXE data maps. AXSIA implements a multivariate curve resolution technique that reduces the spectral image data sets into a limited number of physically realizable and easily interpretable components (including both spectra and images). We show that the principal component spectra can be further analyzed using conventional PIXE programs to convert the weighting images into quantitative concentration maps. A common elemental data set has been analyzed using three different PIXE analysis codes and the results compared to the cases when each of these codes is used to separately analyze the associated AXSIA principal component spectral data. We find that these comparisons are in good quantitative agreement with each other

  4. PIXE analysis: an option for the study of atmospheric pollutants

    International Nuclear Information System (INIS)

    Aldape, U.F.

    1989-01-01

    Several techniques have been utilized in studying atmospheric contamination samples. However, each lack some characteristics required for these studies. Spectroscopy of X-rays particularly where excitation models are produced using charged particles (Particle Induced X-ray Emission, PIXE), for its high sensitivity, is the one that best fitting itself to the scheme of analysis required. In this paper we report some qualitative results of the atmospheric aerosol samples collected in Mexico City. (Author)

  5. PIXE analysis of trace elements in cetacean teeth

    International Nuclear Information System (INIS)

    Mitani, Yoko; Arai, Nobuaki; Sakamoto, Wataru; Yoshida, Koji

    1997-01-01

    PIXE was adopted for analysis of trace elements in teeth of two species of cetaceans, sperm whale (Physeter microcephalus) and pantropical spotted dolphin (Stenella attenuata). The analyses were performed along with the growth layer of the teeth, which is formed annually, suitable for age determination. Mn, Fe, Cu, Zu and Sr were detected in the teeth of sperm whale and pantropical spotted dolphin. Among these trace elements, gradual increase was observed for Zn/Ca ratio in the sperm whale's teeth. (author)

  6. In-air micro-pixe analysis of tissue samples

    International Nuclear Information System (INIS)

    Tanaka, A.; Ishii, K.; Komori, Y.

    2002-01-01

    Micro-PIXE is capable of providing spatial distributions of elements in the micro-meter scale and its application to biology is useful to elucidate the cellular metabolism. Since, in this method, a sample target is usually irradiated with proton or α-particle beams in vacuum, beam heating results in evaporation of volatile elements an shrinking of the sample. In order to avoid these side effects, we previously developed a technique of in-air micro-PIXE analysis for samples of cultured cells. In addition to these, analysis of exposed tissue samples from living subjects is highly desirable in biological and medical research. Here, we describe a technique of in-air micro-PIXE analysis of such tissue samples. The target samples of exposed tissue slices from a Donryu rat, in which a tumor had been transplanted, were analyzed with proton micro-beams of 2.6 MeV. We report that the shape of cells and the distribution of volatile elements in the tissue sample remain uncharged when using a target preparation based on a freeze-drying method. (author)

  7. Qualitative PIXE analysis of mineral elements in some phytopharmaceutic drugs

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Harangus, Livia; Gugiu, M; Iordan, Andreea; Ciortea, C.

    2002-01-01

    A large number of phytopharmaceutic drugs are being developed, due to positive effects in various diseases and to high tolerance by the organism. While their medicinally active compounds have been identified, little attention has been paid to their mineral micro- and trace elements. The mineral elements in the drug may have therapeutic or toxic effects which should be properly assessed. Nuclear and atomic methods allow sensitive multielement detection and we previously performed nuclear activation analysis of some Romanian drugs made by plants. Despite this method's high sensitivity, its use is limited by the availability of a nuclear reactor. Particle-induced X-ray emission (PIXE) provides an alternative, and here we examined its potential for the analysis of mineral elements in three commercial phytopharmaceutical preparations, namely, Liv52, Mentat, and Geriforte. The PIXE measurements were performed with 3 MeV protons at the 8.5 MV NIPNE-HH tandem accelerator, using a hyper pure Ge detector, normally oriented and connected to a multichannel analyzer and to a computer; the drug pills were fixed at 45 angle with respect to the beam. In all drugs PIXE detected mineral elements with Z > 16 down to trace levels. Major elements included K, Ca, Fe, Cu, and Zn, and minor/trace amounts of S, Cl, Ti, Cr, Mn, Ni, Ga, Br, Rb, Sr, Hg, and As/Pb were detected. Some differences were seen between the three drugs. Although at trace levels Ga, As, Hg and Pb are not toxic, one should consider that their accumulation might be harmful and caution seems recommendable on long-term cure. Most of the other elements are known to exert a positive biological role, and both in major and trace levels they may contribute to the therapeutic action. Thus PIXE analysis of mineral elements in phytopharmaceutic drugs, even qualitative, is useful for evaluating the benefits and risks in the therapy. (authors)

  8. PIXE analysis of marine environmental samples from the Pacific Ocean

    International Nuclear Information System (INIS)

    Miyake, Hiroshi; Matsuda, Yasuhiro; Shitashima, Kiminori; Tsubota, Hiroyuki.

    1990-01-01

    Aerosol samples from the western North Pacific Ocean are collected during a cruise of R/V Hakuhomaru from Japan to Hawaii and they are analyzed by PIXE (particle induced X-ray emission). Concentrations of radon daughters are measured with CR-39 track detectors mounted on the impactor to estimate the transport time of air mass from the Asian Continent. Distributions of particulate element concentrations clearly demonstrate the influence of the westerlies. Strong correlations are observed between fine sulphur concentrations and those of heavy metals such as Fe and Zn. Vertical profiles of heavy metal elements contained in marine particulates are also investigated at a trench in the Pacific Ocean and basins in the Japan Sea. Particulate element concentrations determined by PIXE agree well with those determined by chemical analysis of filtered/total water. Remarkable changes in depth profiles of particulate manganese are observed at the trench, which suggest horizontal transport of marine particulates from the trench wall. (N.K.)

  9. PIXE analysis of exhaust gas from diesel engine

    International Nuclear Information System (INIS)

    Miyake, Hirosi; Michijima, Masami; Onishi, Masayuki; Fujitani, Tatsuya.

    1986-01-01

    The variation of elemental concentrations in exhaust gas of a Diesel engine with the outputs was studied. Particulates in high temperature gas were collected on silica fiber filters and analyzed by PIXE method. Concentrations of S and V were nearly proportional to particulate masses and fuel consumption rates per discharging rates of exhaust gas respectively. While, concentrations of Fe and Mn were markedly increased together with engine outputs, and Mn/Fe ratios were nearly equal to those of the material of piston rings and the cylinder liner. Concentrations of the elements contained in lubricant, such as Ca and Mo, were also conspicuously increased with the outputs. It was shown that PIXE analysis is a useful tool for engine diagonostics owing to its high sensitive multi-elemental availability without chemical treatments. (author)

  10. Calibration of a PIXE system for analysis of environmental aerosols

    International Nuclear Information System (INIS)

    Aldape, F.; Diaz, R.V.; Anguiano, G.; Flores M, J.

    1991-04-01

    The results of the calibration of the PIXE system for analysis of environmental aerosols in the CNM is presented. The system was calibrated in order to lead to the project study of environmental aerosols using PIXE from the qualitative dimension to the quantitative one. Part of this work it was carried out in collaboration with the expert of the IAEA Dr. D. Crumpton. The calibration of the system it was achieved bombarding thin targets of well-known composition with protons of 2.5 MeV. Using this technique it was determined the absolute elementary concentration in samples of atmospheric aerosols. As an example the calculation of the lead concentration in one of them whose result was of 662 ± 49 ng m -3 is presented. This value agrees with the measurements made in the Crocker Nuclear Lab of the UCD. Its are also discussed the reproducibility and precision of the used technique. (Author)

  11. PIXE analysis of Nigerian flour and bread samples

    Science.gov (United States)

    Olise, Felix S.; Fernandes, Adriana M.; Cristina Chaves, P.; Taborda, Ana; Reis, Miguel A.

    2014-01-01

    The alleged use of potassium bromate (KBrO3) in bread baking led a few authors to report on the chemical methods for the determination of KBrO3 levels in bread. In order to examine the potentials of a non chemical particle induced X-ray emission (PIXE) method for this purpose, six sets of samples, each composed of flour, dough and bread from a production batch were analysed. The samples were obtained from six different bakers of bread at Ile-Ife, Nigeria. The flour samples were air-dried while others were freeze dried at about -16 °C. The samples were homogenised in an agate mortar and then pelletised. Samples were analysed at the CTN standard PIXE setup and standard procedures for thick target samples analysis were followed. In some samples significant concentrations of bromine were found. In the present work we present possible explanations for the presence of this potentially dangerous contaminant in the samples.

  12. A novel preconcentration technique for the PIXE analysis of water

    International Nuclear Information System (INIS)

    Savage, J.M.; Robertson, J.D.; Majidi, V.

    1994-01-01

    The potential of using dried algae as a novel preconcentration technique for the analysis of water samples by PIXE was examined. 5 mg of dried algae powder were mixed with 5 mL of single- and multi-metal solutions. The algae cells were then collected by filtration on 0.6 um polycarbonate membranes and analyzed by PIXE using a dual energy irradiation. When C. vulgatis was used on mixed metal solutions, linear responses were observed for Ag + , Ba 2+ , and Cd 2+ in the concentration range from 10 ng/g to 1 ug/g; for Cu 2+ and Pb 2+ from 10 ng/g to 5 ug/g; and for Hg 2+ from 10 ng/g to 10 ug/g. When S. bacillaris was used, linear responses were observed from 10 ng/g up to 10 ug/g for all of the metal cations investigated. The PIXE results demonstrated that metal binding at low concentrations involves replacement of sodium on the cell wall and that at high concentrations magnesium is also replaced

  13. PIXE analysis of Nigerian flour and bread samples

    Energy Technology Data Exchange (ETDEWEB)

    Olise, Felix S., E-mail: felix_olise@rushpost.com [Department of Physics, Obafemi Awolowo University, Ile-Ife 220005 (Nigeria); Fernandes, Adriana M.; Cristina Chaves, P. [CFA: Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); Taborda, Ana; Reis, Miguel A. [IST/CTN: Instituto Superior Técnico, Universidade Técnica de Lisboa, Campus Tecnológico e Nuclear (CTN), EN10, 2686-953 Sacavém (Portugal); CFA: Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal)

    2014-01-01

    Highlights: • The PIXE technique has been used to determine K and Br in a major Nigerian food item. • Samples were analysed using two proton beam energies, namely 1.25 MeV and 2.15 MeV. • Mismatched Ca results reflect its nature and accuracy/precision of the procedure. • Explanations for the presence of the contaminant in the samples are presented. • Other sources originating from erroneous burning of dangerous products suspected. -- Abstract: The alleged use of potassium bromate (KBrO{sub 3}) in bread baking led a few authors to report on the chemical methods for the determination of KBrO{sub 3} levels in bread. In order to examine the potentials of a non chemical particle induced X-ray emission (PIXE) method for this purpose, six sets of samples, each composed of flour, dough and bread from a production batch were analysed. The samples were obtained from six different bakers of bread at Ile-Ife, Nigeria. The flour samples were air-dried while others were freeze dried at about −16 °C. The samples were homogenised in an agate mortar and then pelletised. Samples were analysed at the CTN standard PIXE setup and standard procedures for thick target samples analysis were followed. In some samples significant concentrations of bromine were found. In the present work we present possible explanations for the presence of this potentially dangerous contaminant in the samples.

  14. PIXE analysis of Nigerian flour and bread samples

    International Nuclear Information System (INIS)

    Olise, Felix S.; Fernandes, Adriana M.; Cristina Chaves, P.; Taborda, Ana; Reis, Miguel A.

    2014-01-01

    Highlights: • The PIXE technique has been used to determine K and Br in a major Nigerian food item. • Samples were analysed using two proton beam energies, namely 1.25 MeV and 2.15 MeV. • Mismatched Ca results reflect its nature and accuracy/precision of the procedure. • Explanations for the presence of the contaminant in the samples are presented. • Other sources originating from erroneous burning of dangerous products suspected. -- Abstract: The alleged use of potassium bromate (KBrO 3 ) in bread baking led a few authors to report on the chemical methods for the determination of KBrO 3 levels in bread. In order to examine the potentials of a non chemical particle induced X-ray emission (PIXE) method for this purpose, six sets of samples, each composed of flour, dough and bread from a production batch were analysed. The samples were obtained from six different bakers of bread at Ile-Ife, Nigeria. The flour samples were air-dried while others were freeze dried at about −16 °C. The samples were homogenised in an agate mortar and then pelletised. Samples were analysed at the CTN standard PIXE setup and standard procedures for thick target samples analysis were followed. In some samples significant concentrations of bromine were found. In the present work we present possible explanations for the presence of this potentially dangerous contaminant in the samples

  15. Combined PIXE and XPS analysis on republican and imperial Roman coins

    International Nuclear Information System (INIS)

    Dacca, A.; Prati, P.; Zucchiatti, A.; Lucarelli, F.; Mando, P.A.; Gemme, G.; Parodi, R.; Pera, R.

    2000-01-01

    A combined PIXE and XPS analysis has been performed on a few Roman coins of the republican and imperial age. The purpose was to investigate via XPS the nature and extent of patina in order to be capable of extracting PIXE data relative to the coins bulk. The inclusion of elements from the surface layer, altered by oxidation and inclusion, is a known source of uncertainty in PIXE analyses of coins, performed to assess the composition and the provenance

  16. Analysis of trace elements in human hair by PIXE

    International Nuclear Information System (INIS)

    Baptista, G.B.; Montenegro, E.C.; Paschoa, A.S.; Barros Leite, C.V. de.

    1980-10-01

    The PIXE method was applied to the analysis of trace elements in scalp hair using two methods for target preparation. In the first method eigth hair strands each with nearly cylindrical geommetry and approximately the same diameter were selected and placed on an aluminum frame. In the second method a given mass of hair was dissolved with nitric acid and a known amount of strontium was added to the solution and dripped on a membrane filter using a micropipet. The results for the concentrations of trace elements in hair obtained by the two methods are compared and several aspects of the analysis is discussed. (Author) [pt

  17. PIXE analysis of Chinese ancient greenish white porcelain

    International Nuclear Information System (INIS)

    Cheng Lin; Ding Xunliang; Feng Songlin; Cheng Huangsheng; Zhang WenJiang; Fan Changsheng

    2006-01-01

    This paper reports the results about the PIXE analysis of major, minor and trace elements of Chinese ancient greenish white porcelain and blue-and-white porcelain produced in Hutian Kiln (Jingdezhen district, Jiangxi province) during 10th-14th centuries. The porcelain body and greenish white glaze from northern Song (AD 960), southern Song (AD 1037-1276), early Yuan (AD 1279-1320), later Yuan (AD 1320-1368) were investigated together with white-and-blue glaze from Ming dynasty (AD 1368-1644). The obtained data were further analyzed by factor analysis

  18. PIXE analysis of Chinese ancient greenish white porcelain

    Energy Technology Data Exchange (ETDEWEB)

    Cheng Lin [Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing 100875 (China)]. E-mail: chenglinbnu@hotmail.com; Ding Xunliang [Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing 100875 (China); Feng Songlin [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Cheng Huangsheng [Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Zhang WenJiang [Jiangxi Provincial Institute of Cultural Relics and Archaeology, Nanchang 330008 (China); Fan Changsheng [Jiangxi Provincial Institute of Cultural Relics and Archaeology, Nanchang 330008 (China)

    2006-03-15

    This paper reports the results about the PIXE analysis of major, minor and trace elements of Chinese ancient greenish white porcelain and blue-and-white porcelain produced in Hutian Kiln (Jingdezhen district, Jiangxi province) during 10th-14th centuries. The porcelain body and greenish white glaze from northern Song (AD 960), southern Song (AD 1037-1276), early Yuan (AD 1279-1320), later Yuan (AD 1320-1368) were investigated together with white-and-blue glaze from Ming dynasty (AD 1368-1644). The obtained data were further analyzed by factor analysis.

  19. PIXE analysis of Chinese ancient greenish white porcelain

    Science.gov (United States)

    Cheng, Lin; Ding, Xun-liang; Feng, Song-lin; Cheng, Huang-sheng; Zhang, Wen-Jiang; Fan, Chang-Sheng

    2006-03-01

    This paper reports the results about the PIXE analysis of major, minor and trace elements of Chinese ancient greenish white porcelain and blue-and-white porcelain produced in Hutian Kiln (Jingdezhen district, Jiangxi province) during 10th-14th centuries. The porcelain body and greenish white glaze from northern Song (AD 960), southern Song (AD 1037-1276), early Yuan (AD 1279-1320), later Yuan (AD 1320-1368) were investigated together with white-and-blue glaze from Ming dynasty (AD 1368-1644). The obtained data were further analyzed by factor analysis.

  20. Qualitative analysis of a powdered diamond sample by particle induced X-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Mabida, C.; Annegarn, H.J.; Renan, M.J.; Sellschop, J.P.F.

    The main purpose of this analysis was to determine whether nickel is present in diamond powder as a trace element. Particle induced X-ray emission (PIXE) showed unambiguously that nickel was present. Due to the convenience of PIXE in multielemental analysis, the investigations also include a number of other trace elements in the sample

  1. The quantitative analysis of 163Ho source by PIXE

    International Nuclear Information System (INIS)

    Sera, K.; Ishii, K.; Fujioka, M.; Izawa, G.; Omori, T.

    1984-01-01

    We have been studying the electron-capture in 163 Ho as a method for determining the mass of electron neutrino. The 163 Ho sources were produced with the 164 Dy(p,2n) reaction by means of a method of internal irradiation 2 ). We applied the PIXE method to determine the total number of 163 Ho atoms in the source. Proton beams of 3 MeV and a method of ''external standard'' were employed for nondestructive analysis of the 163 Ho source as well as an additional method of ''internal standard''. (author)

  2. Element analysis of Japanese traditional papers by PIXE method

    International Nuclear Information System (INIS)

    Suzuki, Tatsuya; Yasuda, Keisuke; Tani, Teruhiro

    2000-01-01

    The Japanese papers, 'washi', are made from the bast fibers of the plants. Since washi have the informations of the raw material plants, there is potentiality of the identification of the production place by the element analysis of the washi. Three kinds of washi made of kozo, which have different habitats, were prepared. The elements in their washi were measured by the PIXE. It was confirmed that the amount of elements included in the washi depend on the habitats of their raw material plants. (author)

  3. PIXE analysis of cerebrospinal fluid before and after brain transplantation

    International Nuclear Information System (INIS)

    Ma Xinpei; Wang Junke.

    1992-01-01

    Considering methodology of PIXE quantitative analysis based on Inner-standard, we provide a simple and convenient method to measure the elemental relative sensitivity curve. The concentrations of 16 various elements in cerebrospinal fluid samples before and after brain transplantation have been investigated and compared with those of normal person's and transplanted tissues. The experimental results show that the brain transplantation results in apparently curative effects in compensating and regulating the element concentrations in cerebrospinal fluid and improvement of elemental physiological metabolism. It illustrates that the appropriate concentrations of trace elements in cerebrospinal fluid play an undoubtedly important role in keeping the normal physiological function of brain and central nervous system. (author)

  4. External-beam PIXE analysis of small sculptures

    International Nuclear Information System (INIS)

    Gyodi, I.; Demeter, I.; Hollos-Nagy, K.; Kovacs, I.; Szokefalvi-Nagy, Z.

    1999-01-01

    Non-destructive analysis of precious art objects is an important tool to solve provenance problems or to facilitate restoration. External beam PIXE analysis is one of the most powerful and popular methods used in this respect. The paper summarises the external beam PIXE set-up at the Accelerator Laboratory in Budapest, and two selected applications are described. Different parts of a small Cambodian metal sculpture probably made in the 11th century were analysed. It was observed that the sculpture was composed of an iron core and an outer bronze shell. This sculptural technique was well known in the Middle-East but no indication has been found about its use in the Far-East, yet. Before its restoration paint traces on a wooden relief of St. Jerome made by an unknown artist in about 1600 were analysed. Different white and red paints were distinguished at selected points and the presence of titanium on a certain part of the relief was attributed to a repainting in modern times

  5. A novel preconcentration technique for the PIXE analysis of water

    International Nuclear Information System (INIS)

    Savage, J.M.; Fernandez, R.F.; Zhang, W.; Robertson, J.D.; Majidi, V.

    1995-01-01

    The potential of using dried algae as a novel preconcentration technique for the analysis of water samples by PIXE was examined. The algae cells were found to contain significant levels of P and S, indicative of phosphorous- and sulfur-containing groups on the cell wall or inside the algae cells which may serve as potential binding sites for metal ions. When C. vulgaris was used on mixed metal solutions, linear responses were observed for Ag + , Ba 2+ , and Cd 2+ in the concentration range from 10 ng/g to 1 μg/g; for Cu 2+ and Pb 2+ from 10 ng/g to 5 μg/g; and for Hg 2+ from 10 ng/g to 10 μg/g. When S. bacillaris was used, linear responses were observed from 10 ng/g up to 10 μg/g for all of the metal cations investigated. The PIXE results demonstrated that metal binding at low concentrations involves replacement of sodium on the cell wall and that at high concentrations magnesium was also replaced. Competitive binding studies indicate that the metal ions, Ag + , Ba 2+ , Cd 2+ , Cu 2+ , and Pb 2+ , share common binding sites with binding efficiencies varying in the sequence of Pb 2+ >Cu 2+ >Ag 2+ >Cd 2+ >Ba 2+ . The binding of Hg 2+ involved a different binding site with an increase in binding efficiency in the presence of Ag + . (orig.)

  6. PIXE analysis for bioaccumulation studies of trace elements

    International Nuclear Information System (INIS)

    Iwata, Y.; Satoh, A.; Sasaki, Y.; Ito, R.; Kuramachi, K.

    2005-01-01

    Bioaccumulation by micro-alga in the ocean was simulated in nutritive seawater containing known amounts of trace metals, and the concentration factors for Fe, Zn and Cd were measured by PIXE. Trace transition metals in nearshore seawater were removed by Chelex-100. Then a culture solution was prepared by adding known amounts of trace metals and nutritive salts to the purified seawater. Marine micro-algae (Nannochloropsis sp., and Phaeodactylum sp.,) were purely cultured in the culture solution. An interested metal ion was added to the culture solution (0.01-5.0 mg/l). Alga in 10 ml of the culture solution was collected on a polycarbonate filter (pore size: 1.0 ) by suction filtration and subjected to 2.9 MeV proton bombardment. Na, Mg, Al, Si, P, S, Cl, K, Ca, Cr, Mn, Fe, Zn and Cd were simultaneously determined. PIXE multi-element analysis was possible using less than 1 mg of analytical sample. The quantity of the metal in the alga was increased in proportion to the concentration in the culture solution. The concentration factors for Zn, Fe and Cd were measured, e.g., 10200 ± 300 ml/g to Zn for Phaeodactylum. The trend of the affinity for the trace metals in the case of Nannochloropsis was Fe 3+ > Zn 2+ > Pb 2+ > Cd 2+ . (author)

  7. External-RBS, PIXE and NRA analysis for ancient swords

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Hellen C., E-mail: hellencsa@gmail.com; Added, Nemitala; Silva, Tiago F.; Rodrigues, C.L.

    2015-02-15

    Elemental composition of the steel of two ancient swords (Japanese and Damascus from a private collection) was characterized using in air IBA techniques. Our results contribute for the understanding the processes of manufacturing (hammering and quenching) and surface treatments applied in these swords. The Particle Induced X-ray Emission (PIXE) measurements along the Damascus blade allowed to identify and to trace a superficial concentration profile for the elements such Cr, Mn, Fe, Ni, Cu, Zn and As, while results for the Japanese blade showed only the presence of iron. The carbon content on the surface was also investigated using a resonant region in the Elastic Backscattering Spectrometry (EBS) measurements and the results have shown a slightly difference between the surfaces under investigation. In order to investigate the nitrogen content on surface, that could explain the hardening process, we used Nuclear Reaction Analysis (NRA) and the results shown that nitrogen content was under our detection limit for the technique (0.3% in mass). The measurements of PIXE, NRA and EBS were taken using the external beam setup installed at Lamfi – São Paulo/Brazil, the latter being successfully implemented for the first time in this facility.

  8. External-RBS, PIXE and NRA analysis for ancient swords

    Science.gov (United States)

    Santos, Hellen C.; Added, Nemitala; Silva, Tiago F.; Rodrigues, C. L.

    2015-02-01

    Elemental composition of the steel of two ancient swords (Japanese and Damascus from a private collection) was characterized using in air IBA techniques. Our results contribute for the understanding the processes of manufacturing (hammering and quenching) and surface treatments applied in these swords. The Particle Induced X-ray Emission (PIXE) measurements along the Damascus blade allowed to identify and to trace a superficial concentration profile for the elements such Cr, Mn, Fe, Ni, Cu, Zn and As, while results for the Japanese blade showed only the presence of iron. The carbon content on the surface was also investigated using a resonant region in the Elastic Backscattering Spectrometry (EBS) measurements and the results have shown a slightly difference between the surfaces under investigation. In order to investigate the nitrogen content on surface, that could explain the hardening process, we used Nuclear Reaction Analysis (NRA) and the results shown that nitrogen content was under our detection limit for the technique (0.3% in mass). The measurements of PIXE, NRA and EBS were taken using the external beam setup installed at Lamfi - São Paulo/Brazil, the latter being successfully implemented for the first time in this facility.

  9. External-RBS, PIXE and NRA analysis for ancient swords

    International Nuclear Information System (INIS)

    Santos, Hellen C.; Added, Nemitala; Silva, Tiago F.; Rodrigues, C.L.

    2015-01-01

    Elemental composition of the steel of two ancient swords (Japanese and Damascus from a private collection) was characterized using in air IBA techniques. Our results contribute for the understanding the processes of manufacturing (hammering and quenching) and surface treatments applied in these swords. The Particle Induced X-ray Emission (PIXE) measurements along the Damascus blade allowed to identify and to trace a superficial concentration profile for the elements such Cr, Mn, Fe, Ni, Cu, Zn and As, while results for the Japanese blade showed only the presence of iron. The carbon content on the surface was also investigated using a resonant region in the Elastic Backscattering Spectrometry (EBS) measurements and the results have shown a slightly difference between the surfaces under investigation. In order to investigate the nitrogen content on surface, that could explain the hardening process, we used Nuclear Reaction Analysis (NRA) and the results shown that nitrogen content was under our detection limit for the technique (0.3% in mass). The measurements of PIXE, NRA and EBS were taken using the external beam setup installed at Lamfi – São Paulo/Brazil, the latter being successfully implemented for the first time in this facility

  10. PIGE-PIXE analysis of chewing sticks of pharmacological importance

    Energy Technology Data Exchange (ETDEWEB)

    Olabanji, S.O. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro; Makanju, O.V. [Drug Research and Production Unit, Faculty of Pharmacy, Obafemi Awolowo University (O.A.U.), Ile-Ife (Nigeria); Haque, A.M.I. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro; Buoso, M.C. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro; Ceccato, D. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro]|[Dipartimento di Fisica, Universita di Padova, I-35131 Padova (Italy); Cherubini, R. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro; Moschini, G. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro]|[Dipartimento di Fisica, Universita di Padova, I-35131 Padova (Italy)

    1996-06-01

    PIGE and PIXE techniques were employed for the determination of the major, minor and trace elemental concentrations in chewing sticks of pharmacological importance namely: Butyrospermum paradoxum, Garcinia kola, Distemonanthus benthamianus, Bridelia ferruginea, Anogeissus leiocarpus, Terminalia glaucescens and Fagara rubescens, respectively. The concentration of fluorine which is very important for human dental enamel was specially determined using the {sup 19}F(p,p`{gamma}){sup 19}F reaction. For decades these chewing sticks when used alone without toothpastes have proven to be very efficient, effective and reliable in cleaning the teeth of many people particularly in Nigeria and some other countries in Africa. The teeth of users are usually very strong, clean, fresh and devoid of germs and caries. Even with the advent of modern toothpastes with special additions of fluorine, the use of these popular and efficient chewing sticks is still unabated. Many people including the elite use them solely, a few others combine their use with modern toothpastes and brush. Proton beams produced by the 7 MV CN and 2.5 MV AN 2000 Van de Graaff accelerators at INFN, Laboratori Nazionali di Legnaro (LNL), Padova, Italy were used for the PIGE and PIXE analysis, respectively. Results of this novel study are presented and discussed. (orig.).

  11. PIGE-PIXE analysis of chewing sticks of pharmacological importance

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Haque, A.M.I.; Cherubini, R.

    1996-01-01

    PIGE and PIXE techniques were employed for the determination of the major, minor and trace elemental concentrations in chewing sticks of pharmacological importance namely: Butyrospermum paradoxum, Garcinia kola, Distemonanthus benthamianus, Bridelia ferruginea, Anogeissus leiocarpus, Terminalia glaucescens and Fagara rubescens, respectively. The concentration of fluorine which is very important for human dental enamel was specially determined using the 19 F(p,p'γ) 19 F reaction. For decades these chewing sticks when used alone without toothpastes have proven to be very efficient, effective and reliable in cleaning the teeth of many people particularly in Nigeria and some other countries in Africa. The teeth of users are usually very strong, clean, fresh and devoid of germs and caries. Even with the advent of modern toothpastes with special additions of fluorine, the use of these popular and efficient chewing sticks is still unabated. Many people including the elite use them solely, a few others combine their use with modern toothpastes and brush. Proton beams produced by the 7 MV CN and 2.5 MV AN 2000 Van de Graaff accelerators at INFN, Laboratori Nazionali di Legnaro (LNL), Padova, Italy were used for the PIGE and PIXE analysis, respectively. Results of this novel study are presented and discussed. (orig.)

  12. PIGE-PIXE analysis of chewing sticks of pharmacological importance

    Science.gov (United States)

    Olabanji, S. O.; Makanju, O. V.; Haque, A. M. I.; Buoso, M. C.; Ceccato, D.; Cherubini, R.; Moschini, G.

    1996-06-01

    PIGE and PIXE techniques were employed for the determination of the major, minor and trace elemental concentrations in chewing sticks of pharmacological importance namely: Butyrospermum paradoxum, Garcinia kola, Distemonanthus benthamianus, Bridelia ferruginea, Anogeissus leiocarpus, Terminalia glaucescens and Fagara rubescens, respectively. The concentration of fluorine which is very important for human dental enamel was specially determined using the 19F(p, p'γ) 19F reaction. For decades these chewing sticks when used alone without toothpastes have proven to be very efficient, effective and reliable in cleaning the teeth of many people particularly in Nigeria and some other countries in Africa. The teeth of users are usually very strong, clean, fresh and devoid of germs and caries. Even with the advent of modern toothpastes with special additions of fluorine, the use of these popular and efficient chewing sticks is still unabated. Many people including the elite use them solely, a few others combine their use with modern toothpastes and brush. Proton beams produced by the 7 MV CN and 2.5 MV AN 2000 Van de Graaff accelerators at INFN, Laboratori Nazionali di Legnaro (LNL), Padova, Italy were used for the PIGE and PIXE analysis, respectively. Results of this novel study are presented and discussed.

  13. Exploring advantages of 4He-PIXE analysis for layered objects in cultural heritage

    International Nuclear Information System (INIS)

    Roehrs, S.; Calligaro, T.; Mathis, F.; Ortega-Feliu, I.; Salomon, J.; Walter, P.

    2006-01-01

    In the field of cultural heritage 4 He particle beams are often used to perform RBS analysis. In most cases the simultaneously produced X-rays are not considered for PIXE analysis. This paper aims to explore the potentials of 4 He induced X-ray emission (α-PIXE) using 4, 5 and 6 MeV 4 He beams and to compare its performance with that of conventional PIXE with 3 MeV protons. The α-PIXE and α-RBS spectra were collected at the same time in a vacuum chamber. The X-ray yields produced by 6 MeV 4 He beam for K-lines were found to be superior to those of protons for atomic numbers below 25. An additional advantage of α-PIXE is the lower bremsstrahlung background which leads to an improved peak to noise ratio for certain elements

  14. Calibration of a PIXE system for analysis of environmental aerosols; Calibracion de un sistema PIXE para analisis de aerosoles ambientales

    Energy Technology Data Exchange (ETDEWEB)

    Aldape, F; Diaz, R V; Anguiano, G; Flores M, J [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1991-04-15

    The results of the calibration of the PIXE system for analysis of environmental aerosols in the CNM is presented. The system was calibrated in order to lead to the project study of environmental aerosols using PIXE from the qualitative dimension to the quantitative one. Part of this work it was carried out in collaboration with the expert of the IAEA Dr. D. Crumpton. The calibration of the system it was achieved bombarding thin targets of well-known composition with protons of 2.5 MeV. Using this technique it was determined the absolute elementary concentration in samples of atmospheric aerosols. As an example the calculation of the lead concentration in one of them whose result was of 662 {+-} 49 ng m{sup -3} is presented. This value agrees with the measurements made in the Crocker Nuclear Lab of the UCD. Its are also discussed the reproducibility and precision of the used technique. (Author)

  15. Sample preparation procedure for PIXE elemental analysis on soft tissues

    International Nuclear Information System (INIS)

    Kubica, B.; Kwiatek, W.M.; Dutkiewicz, E.M.; Lekka, M.

    1997-01-01

    Trace element analysis is one of the most important field in analytical chemistry. There are several instrumental techniques which are applied for determinations of microscopic elemental content. The PIXE (Proton Induced X-ray Emission) technique is one of the nuclear techniques that is commonly applied for such purpose due to its multielemental analysis possibilities. The aim of this study was to establish the optimal conditions for target preparation procedure. In this paper two different approaches to the topic are presented and widely discussed. The first approach was the traditional pellet technique and the second one was mineralization procedure. For the analysis soft tissue such as liver was used. Some results are also presented on water samples. (author)

  16. Quantitative analysis of soluble elements in environmental waters by PIXE

    International Nuclear Information System (INIS)

    Niizeki, T.; Kawasaki, K.; Adachi, M.; Tsuji, M.; Hattori, T.

    1999-01-01

    We have started PIXE research for environmental science at Van de Graaff accelerator facility in Tokyo Institute of Technology. Quantitative measurements of soluble fractions in river waters have been carried out using the preconcentrate method developed in Tohoku University. We reveal that this PIXE target preparation can be also applied to waste water samples. (author)

  17. Non-destructive analysis and identification of jade by PIXE

    International Nuclear Information System (INIS)

    Cheng, H.S.; Zhang, Z.Q.; Zhang, B.; Yang, F.J.

    2004-01-01

    This paper reports the experimental results of identifying jade by proton induced X-ray emission (PIXE) technique. It is found that the jade can be classified, according to the chemical composition determined by PIXE. The experimental results can differentiate ancient Chinese jade works of art from fakes if the material is the same

  18. PIXE analysis of tree leaves as a possible comparative integral monitor of particulates in urban areas

    International Nuclear Information System (INIS)

    Zucchiati, A.; Annegarm, H.J.; Chisci, R.

    1988-01-01

    The possibility of obtaing integral comparative data for particulate distribution in urban areas from PIXE analysis of tree leaves is discussed in relation to the leaf gross anatomy, to the diffusion of selected tree species in such areas and to the implementation of experimental techniques necessary to make PIXE analysis effective. Multielemental scans were performed on a small set samples; results are compared to PIXE analysis of typical urban aerosols. The validity of the method and the criteria for yearly relative comparisons of different areas are discissed

  19. PIXE trace element analysis of a selection of wines

    International Nuclear Information System (INIS)

    Houdayer, A.; Hinrichsen, P.F.; Martin, J.P.; Belhadfa, A.

    1987-01-01

    The University of Montreal EN Tandem accelerator and a Si (Li) X-ray detector were used for a PIXE (Proton Induced X-ray emission) trace element analysis of a selection of wines. Quantitative measurements of the concentrations of the sixteen trace elements Na, Mg, Al, Si, P, S, Cl, K, Ca, Cr, Mn, Fe, Co, Cu, Zn, and Br were made. To optimize the sensitivity, spectra were recorded at 1.0 MeV proton energy for elements with Z 19. The absolute concentrations of the trace elements were determined by doping the samples of wine with 1000 ppm of vanadium for the 1.0 MeV bombardments, and 1000 ppm of yttrium for the 3.0 MeV irradiations. The targets were prepared by depositing a few microliters of the wine onto a Nuclepore filter

  20. PIXE analysis of Italian ink drawings of the XVI century

    International Nuclear Information System (INIS)

    Zucchiatti, A.; Climent-Font, A.; Enguita, O.; Fernandez-Jimenez, M.T.; Finaldi, G.; Garrido, C.; Matillas, J.M.

    2005-01-01

    The composition of inks in a group of 24 drawings of ten XVI century Italian painters, has been determined by PIXE at the external micro-beam line of the Centro de Micro Analisis de Materiales of the Universidad Autonoma de Madrid. Ink elemental thicknesses have been determined by comparison with a set of certified thin standards. A comprehensive comparison of inks has also been performed by renormalisation of spectra and definition of an ink-to-ink distance. The elemental compositions and the ink-to-ink distances give consistent results that are generally in line with the appearance of the drawings and add relevant instrumental information to the stylistic observation, revealing for example the presence of retouches and additions in different parts of a drawing. Cluster analysis performed on a subgroup of 13 artefacts from the Genoese painter Luca Cambiaso and his school has revealed a partition that separates neatly the work of the master from that of his followers

  1. Obisdian sourcing by PIXE analysis at AURA2

    International Nuclear Information System (INIS)

    Neve, S.R.; Barker, P.H.; Holroyd, S.; Sheppard, P.J.

    1994-01-01

    The technique of Proton Induced X-ray Emission is a suitable method for the elemental analysis of obsidian samples and artefacts. By comparing the elemental composition of obsidian artefacts with those of known sources of obsidian and identifying similarities, the likely origin of the sample can be discovered and information about resource procurement gained. A PIXE facility has now been established at the Auckland University Research Accelerator Laboratory, AURA2. It offers a rapid, multi-element, non-destructive method of characterisation of obsidian samples ranging from small chips to large pieces. In an extensive survey of Mayor Island obsidian, a discrimination has been made between the different locations of obsidian deposits on the island. In addition, using the database developed at AURA2, artefacts from the site of Opita, Hauraki Plains, have been sourced. (Author). 18 refs., 8 figs., 7 tabs., 1 appendix

  2. Elemental analysis of artefacts - establishing external beam PIXE

    International Nuclear Information System (INIS)

    Alves, A.; Johnston, P.; Short, R.; Bubb, I.

    1999-01-01

    The development of an external PIXE facility on the 1 MV Tandetron accelerator at RMIT has led to a wide range of research possibilities. A proton beam, generated inside a vacuum is brought into air via an Au coated Kapton foil exit window (thickness 8μm, diameter 0.35mm). Monitoring of the beam intensity is achieved by detecting backscattered protons from the inside Au coating on the window. Artefacts, which may be too large to be placed inside the vacuum, are positioned in the beamline opposite the exit window. An optical system consisting of a CCD camera, alignment laser and two mirrors allows viewing of a region of the target 10mm x 10mm. This technique provides quantitative analysis of elements in the pigments used in paintings and on ceramics, which is a valuable tool in art conservation and authentication. Application of the technique to a ceramic sample from the historic house 'Viewbank' is described

  3. A novel preconcentration technique for the PIXE analysis of water

    Energy Technology Data Exchange (ETDEWEB)

    Savage, J.M. [Element Analysis Corp., Lexington, KY (United States); Fernandez, R.F. [Element Analysis Corp., Lexington, KY (United States); Zhang, W. [Department of Chemistry, University of Kentucky, Lexington, KY 40506-0055 (United States); Robertson, J.D. [Department of Chemistry, University of Kentucky, Lexington, KY 40506-0055 (United States); Majidi, V. [Department of Chemistry, University of Kentucky, Lexington, KY 40506-0055 (United States)

    1995-05-01

    The potential of using dried algae as a novel preconcentration technique for the analysis of water samples by PIXE was examined. The algae cells were found to contain significant levels of P and S, indicative of phosphorous- and sulfur-containing groups on the cell wall or inside the algae cells which may serve as potential binding sites for metal ions. When C. vulgaris was used on mixed metal solutions, linear responses were observed for Ag{sup +}, Ba{sup 2+}, and Cd{sup 2+} in the concentration range from 10 ng/g to 1 {mu}g/g; for Cu{sup 2+} and Pb{sup 2+} from 10 ng/g to 5 {mu}g/g; and for Hg{sup 2+} from 10 ng/g to 10 {mu}g/g. When S. bacillaris was used, linear responses were observed from 10 ng/g up to 10 {mu}g/g for all of the metal cations investigated. The PIXE results demonstrated that metal binding at low concentrations involves replacement of sodium on the cell wall and that at high concentrations magnesium was also replaced. Competitive binding studies indicate that the metal ions, Ag{sup +}, Ba{sup 2+}, Cd{sup 2+}, Cu{sup 2+}, and Pb{sup 2+}, share common binding sites with binding efficiencies varying in the sequence of Pb{sup 2+}>Cu{sup 2+}>Ag{sup 2+}>Cd{sup 2+}>Ba{sup 2+}. The binding of Hg{sup 2+} involved a different binding site with an increase in binding efficiency in the presence of Ag{sup +}. (orig.).

  4. Examination of quantitative accuracy of PIXE analysis for atmospheric aerosol particle samples. PIXE analysis of NIST air particulate on filter media

    International Nuclear Information System (INIS)

    Saitoh, Katsumi; Sera, Koichiro

    2005-01-01

    In order to confirm accuracy of the direct analysis of filter samples containing atmospheric aerosol particles collected on a polycarbonate membrane filter by PIXE, we carried out PIXE analysis on a National Institute of Standards and Technology (NIST, USA) air particulate on filter media (SRM 2783). For 16 elements with NIST certified values determined by PIXE analysis - Na, Mg, Al, Si, S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn and Pb - quantitative values were 80-110% relative to NIST certified values except for Na, Al, Si and Ni. Quantitative values of Na, Al and Si were 140-170% relative to NIST certified values, which were all high, and Ni was 64%. One possible reason why the quantitative values of Na, Al and Si were higher than the NIST certified values could be the difference in the X-ray spectrum analysis method used. (author)

  5. PIXE analysis of otoliths from several species of teleost fish

    International Nuclear Information System (INIS)

    Arai, Nobuaki; Sakamoto, Wataru; Maeda, Kuniko.

    1994-01-01

    In-air PIXE was used to analyze trace elements in otoliths from several species of teleost fish in order to examine the correlation between the trace elements concentrations and environmental conditions. Mn, Fe, Zn and Sr were detected accurately in the order of ppm by using the in-air PIXE. It seemed that concentrations of Sr and Zn in red sea bream otoliths increased in proportion to higher seawater temperature. In addition, there were significant differences in trace element composition between that of reared red sea bream and rockfish and that of wild ones. Preliminary results indicate that the PIXE is a powerful technique to investigate fish otoliths. (author)

  6. Analysis of kidney stones by PIXE and RBS techniques

    International Nuclear Information System (INIS)

    Alkofai, M.M.; Hallak, A.B.

    1995-01-01

    Human kidney stones were analyzed by PIXE and RBS techniques using 2 MeV He ++ beam. The stones were found to contain the elements: C, N, O, F, Na, Mg, Si, P, S, Cl, K, Ca, Fe and Br. Results obtained by PIXE agree with the results obtained by RBS within experimental errors. A Mechanism for the formation of the kidney stones is suggested. 3 figs., 1 tab

  7. Analysis of kidney stones by PIXE and RBS techniques

    Energy Technology Data Exchange (ETDEWEB)

    Alkofai, M M [Physics Dept., Yarmouk University, Irbid, (Jordan); Hallak, A B [Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261, (Saudi Arabia)

    1995-10-01

    Human kidney stones were analyzed by PIXE and RBS techniques using 2 MeV He{sup ++} beam. The stones were found to contain the elements: C, N, O, F, Na, Mg, Si, P, S, Cl, K, Ca, Fe and Br. Results obtained by PIXE agree with the results obtained by RBS within experimental errors. A Mechanism for the formation of the kidney stones is suggested. 3 figs., 1 tab.

  8. PIXE analysis of human stones: comparison with data from ICP-AES

    International Nuclear Information System (INIS)

    Pougnet, M.A.B.; Peisach, M.; Pineda, C.A.; Rodgers, A.L.

    1987-01-01

    25 human stone samples previously analyzed by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and the IAEA Animal Bone Standard Reference Material were used to evaluate trace element analysis by PIXE. Bombardment with 4 MeV protons was used for the determination of Mn, Fe, Cu, Pb, Br, Rb, Sr and Ca. PIXE and ICP-AES data gave correlation factors better than 0.97 for the elements Ca, Fe, Zn, Sr and Pb. (author) 9 refs.; 5 figs

  9. Analysis of micro matter reference materials of lichen and algae by SRXRF and PIXE

    International Nuclear Information System (INIS)

    Yin Sha Xin; Wang Jian Liu; Zhang Peiqun

    2002-01-01

    In the present work two nuclear micro analysis techniques, synchrotron radiation (SRXRF) and macro proton induced X ray emission (macro PIXE), were used in the homogeneity test of Algae IAEA-413 and Lichen IAEA-338, and the certification of their elemental contents too. Finally, the Ingamell's sampling constant Ks and the relative homogeneity factor HE of some elements in these two RMs were estimated on the base of our macro PIXE results. (author)

  10. Total CMB analysis of streaker aerosol samples by PIXE, PIGE, beta- and optical-absorption analyses

    International Nuclear Information System (INIS)

    Annegarn, H.J.; Przybylowicz, W.J.

    1993-01-01

    Multielemental analyses of aerosol samples are widely used in air pollution receptor modelling. Specifically, the chemical mass balance (CMB) model has become a powerful tool in urban air quality studies. Input data required for the CMB includes not only the traditional X-ray fluorescence (and hence PIXE) detected elements, but also total mass, organic and inorganic carbon, and other light elements including Mg, Na and F. The circular streaker sampler, in combination with PIXE analysis, has developed into a powerful tool for obtaining time-resolved, multielemental aerosol data. However, application in CMB modelling has been limited by the absence of total mass and complementary light element data. This study reports on progress in using techniques complementary to PIXE to obtain additional data from circular streaker samples, maintaining the nondestructive, instrumental approach inherent in PIXE: Beta-gauging using a 147 Pm source for total mass; optical absorption for inorganic carbon; and PIGE to measure the lighter elements. (orig.)

  11. Analysis of biological materials by RBS and PIXE methods

    International Nuclear Information System (INIS)

    Latuszynski, A.; Maczka, D.; Kobzev, A. P.

    2002-01-01

    A problem of the exact determination of the element concentration in different substances is of essential significance, especially in medical, biological, as well as environment protection investigations. For this purpose some chemical and physical methods are used such as very sensitive and precise techniques: PIXE and RBS. The main advantage of those methods is the sensitivity of ppm level and very small sample amount necessary for carrying out the investigations. In this article the investigation results obtained by PIXE and RBS methods for the metal contents in cow milk (18 various samples were studied) as well as the heavy metal admixtures in the brain of the living domestic animals (6 cows, 6 dogs and 17 rats) are presented. The samples were prepared for the analysis in a liofilization process, then they were mixed with spectral pure graphite. The PIXE and RBS investigations were performed using a proton beam of about 2 mm diameter, intensity of about 10 nA and energy of 2.5 MeV from the Van-de-Graaff generator, FLNP, JINR, Dubna. The measurements of the characteristic spectrum were carried out by means of a Si (Li) detector with the resolution of 200 eV at the energy of 6,4 keV. Generally, in all samples of milk and brain we could identify 20 elements, among them 13 (C, N, O, P, Cl, K, Ca, Fe, Cu, Zn. Br, Rb, Sr) appeared in all of the studied samples. The difference in the concentration of the most of those elements between samples was in the range of 15 - 20 %. This indicates a good accuracy of the used methods of measurement. Especially our attention was paid to the presence of Sr, Rb and Br, practically in all the milk samples. This fact requires further investigations. Such elements as Pb, As, Ni, Co, Mn, V and Ti were found in some samples, including all samples coming from regions of a high urbanization. It is characteristic that the milk samples coming from villages located considerably far-away from cities and from communication tracks, practically

  12. Element analysis on Japanese ancient glass by PIXE method

    International Nuclear Information System (INIS)

    Koizumi, Y.; Kobayashi, K.

    2001-01-01

    The authors analyzed ancient glasses using PIXE (particle induced X-ray emission) method associated with the accelerator used for the trace analysis of environments and organisms. They examined whether the material properties of the glasses made by ancient technology have correlation with those of each era or each region both in and out of Japan. The alkali lime glasses excavated from Japanese ancient ruins are classified as soda lime glasses and potash lime glasses, and intermediate glasses containing both are also detected. As for the glasses between the late Yayoi period and the early Tumulus period in eastern Japan, glass beads were mostly classified as potash lime glasses. In the mid and late Tumulus periods, soda lime glasses and the glasses with an intermediate composition increased in addition to potash lime glasses. In the analysis of the glass beads excavated from the ruins of the late Yayoi period to the early Tumult period in Tsushima, potash lime glasses and soda lime glasses coexisted in the same period. Most of the coloring components of deep-blue system mostly found in eastern Japan were manganese and iron, and the coloring components such as blue, green, sky blue, etc. were copper. Yellow was the color expressed with lead or lead - iron. The coloring materials were common regardless of the classification of glasses based on main components. (A.O.)

  13. Developments in Dynamic Analysis for quantitative PIXE true elemental imaging

    International Nuclear Information System (INIS)

    Ryan, C.G.

    2001-01-01

    Dynamic Analysis (DA) is a method for projecting quantitative major and trace element images from PIXE event data-streams (off-line or on-line) obtained using the Nuclear Microprobe. The method separates full elemental spectral signatures to produce images that strongly reject artifacts due to overlapping elements, detector effects (such as escape peaks and tailing) and background. The images are also quantitative, stored in ppm-charge units, enabling images to be directly interrogated for the concentrations of all elements in areas of the images. Recent advances in the method include the correction for changing X-ray yields due to varying sample compositions across the image area and the construction of statistical variance images. The resulting accuracy of major element concentrations extracted directly from these images is better than 3% relative as determined from comparisons with electron microprobe point analysis. These results are complemented by error estimates derived from the variance images together with detection limits. This paper provides an update of research on these issues, introduces new software designed to make DA more accessible, and illustrates the application of the method to selected geological problems.

  14. Below-surface analysis of inclusions with PIXE and PIGE

    International Nuclear Information System (INIS)

    MacArthur, J.D.; Ma, X.P.; Palmer, G.R.; Anderson, A.J.; Clark, A.H.

    1990-01-01

    The composition of fluid inclusions in host minerals holds much information about the chemical environment of mineral formation. When solid inclusions are exposed through polishing, their content can readily be investigated with an electron or proton probe. However, with an electron probe, only the daughter minerals or the residue material left when a fluid inclusion is opened can be analyzed since electrons with energies of tens of keV cannot penetrate to the unexposed inclusion. On the other hand, proton beams of a few MeV can penetrate a few tens of μm of material and still be able to excite characteristic radiation. This phenomenon has been exploited for the analysis of subsurface inclusions. Ideally, standard petrographic sections are polished to that inclusions, targetted for analysis, are brought to within 10 μm of the surface. The overlying matrix reduces the sensitivity of PIXE for the elements of low Z such as Na and Al because of the attenuation of the X-rays. However, these elements, as well as elements of even lower Z, which cannot be analyzed with the electron probe, can readily be detected with PIGE at good sensitivity. (orig.)

  15. PIXE analysis of Italian ink drawings of the XVI century

    Science.gov (United States)

    Zucchiatti, A.; Climent-Font, A.; Enguita, O.; Fernandez-Jimenez, M. T.; Finaldi, G.; Garrido, C.; Matillas, J. M.

    2005-10-01

    The composition of inks in a group of 24 drawings of ten XVI century Italian painters, has been determined by PIXE at the external micro-beam line of the Centro de Micro Análisis de Materiales of the Universidad Autónoma de Madrid. Ink elemental thicknesses have been determined by comparison with a set of certified thin standards. A comprehensive comparison of inks has also been performed by renormalisation of spectra and definition of an ink-to-ink distance. The elemental compositions and the ink-to-ink distances give consistent results that are generally in line with the appearance of the drawings and add relevant instrumental information to the stylistic observation, revealing for example the presence of retouches and additions in different parts of a drawing. Cluster analysis performed on a subgroup of 13 artefacts from the Genoese painter Luca Cambiaso and his school has revealed a partition that separates neatly the work of the master from that of his followers.

  16. PIXE analysis of cancer-afflicted human bladder

    Energy Technology Data Exchange (ETDEWEB)

    Raju, G.J. Naga; Sarita, P.; Kumar, M. Ravi [Department of Physics, Institute of Technology, GITAM University, Visakhapatnam (India); Reddy, S. Bhuloka [Swami Jnanananda Laboratories for Nuclear Research, Andhra University, Visakhapatnam (India)

    2013-07-01

    Full text: The proton induced x-ray emission (PIXE) technique was used for analysis of trace elements in small quantities of biological samples. Both the biological samples of normal and cancer-afflicted human bladder tissues were studied. The present experiment was performed using a 3 MV pelletron accelerator at the Institute of Physics in Bhubaneswar, India. A proton beam of 3 MeV energy was used to excite the samples. NIST SRM 1577b Bovine Liver Tissue was used as external standards for the determination of trace element concentration in the biological tissue samples. The elements CI, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, and Se were identified and their concentrations were estimated. The concentrations of Ti and Zn are lower (p < 0.005) and that of Cr, Mn, Fe, Ni, and Cu are significantly higher (p < 0.001) in cancerous tissues than that in normal tissues. The deficiency or excess of different trace elements observed in the cancer tissues relative to the normal tissues of bladder are correlated to the pathology of cancer. (author)

  17. PIXE analysis of historical paintings: Is the gain worth the risk?

    International Nuclear Information System (INIS)

    Calligaro, T.; Gonzalez, V.; Pichon, L.

    2015-01-01

    The PIXE analysis of easel paintings constitutes a challenging task. Despite recognized merits and a few emblematic applications, PIXE has never been routinely applied to these fragile, complex and precious targets. The present work discusses the place of PIXE in the study of easel paintings and opens up perspectives for a more systematic usage of this analytical technique. Progress achieved since decades in the implementation of PIXE to study such fragile cultural heritage artefacts is reviewed, notably at the LABEC laboratory in Italy and at the AGLAE facility of the C2RMF in France. Two specific techniques developed for paintings are detailed and exemplified on Renaissance painting masterpieces: differential PIXE for paint layers depth profiling and multi-scale elemental mapping for the imaging of pigment distribution. Beam-induced damage, a major concern, notably depends on the employed beam fluence in particle/cm"2 or μC/cm"2. After recalling previous works on damage induced in chemical products comparable to pigments, we present the behaviour under different fluences of protons of a few MeV (1–300 μC/cm"2) of targets having high resemblance to historical easel paintings: pellets of specially synthesized lead white pigments, layers of lead white mixed with linseed oil and areas containing lead white of two 19th century paintworks. The results shed new lights on the behaviour of paintworks under the beam and pave the way to strategies for damage mitigation. In particular, the lowering of PIXE performance induced by the decrease of the beam fluence sets a trade-off between risk of damage and gained information which also impacts the PIXE scanning protocol for paintings. As an illustration of an adequate adjustment of this balance, we report the exploratory application of PIXE mapping to a large area of a 19th century easel painting without damage. The recorded elemental maps are compared to elemental maps collected on the same area using laboratory

  18. PIXE analysis of historical paintings: Is the gain worth the risk?

    Science.gov (United States)

    Calligaro, T.; Gonzalez, V.; Pichon, L.

    2015-11-01

    The PIXE analysis of easel paintings constitutes a challenging task. Despite recognized merits and a few emblematic applications, PIXE has never been routinely applied to these fragile, complex and precious targets. The present work discusses the place of PIXE in the study of easel paintings and opens up perspectives for a more systematic usage of this analytical technique. Progress achieved since decades in the implementation of PIXE to study such fragile cultural heritage artefacts is reviewed, notably at the LABEC laboratory in Italy and at the AGLAE facility of the C2RMF in France. Two specific techniques developed for paintings are detailed and exemplified on Renaissance painting masterpieces: differential PIXE for paint layers depth profiling and multi-scale elemental mapping for the imaging of pigment distribution. Beam-induced damage, a major concern, notably depends on the employed beam fluence in particle/cm2 or μC/cm2. After recalling previous works on damage induced in chemical products comparable to pigments, we present the behaviour under different fluences of protons of a few MeV (1-300 μC/cm2) of targets having high resemblance to historical easel paintings: pellets of specially synthesized lead white pigments, layers of lead white mixed with linseed oil and areas containing lead white of two 19th century paintworks. The results shed new lights on the behaviour of paintworks under the beam and pave the way to strategies for damage mitigation. In particular, the lowering of PIXE performance induced by the decrease of the beam fluence sets a trade-off between risk of damage and gained information which also impacts the PIXE scanning protocol for paintings. As an illustration of an adequate adjustment of this balance, we report the exploratory application of PIXE mapping to a large area of a 19th century easel painting without damage. The recorded elemental maps are compared to elemental maps collected on the same area using laboratory-based scanning

  19. Forensic analysis of tempered sheet glass by particle induced X-ray emission (PIXE)

    Energy Technology Data Exchange (ETDEWEB)

    Jisonna, L.J. [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); DeYoung, P.A., E-mail: deyoung@hope.ed [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); Ferens, J.; Hall, C.; Lunderberg, J.M.; Mears, P. [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); Padilla, D. [Department of Physics, San Diego State University, San Diego, CA 92182-1233 (United States); Peaslee, G.F. [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); Sampson, R. [Department of Physics, Columbia University, New York, NY 10027 (United States)

    2011-05-15

    Highlights: {yields} PIXE was found to give the same results for trace elements in glass as ICP. {yields} PIXE can non-destructively determine trace element concentrations in auto glass. {yields} Measured Ca, Fe, Ti, Mn, and Sr in auto glass with PIXE. -- Abstract: The elemental concentrations of five trace elements in tempered sheet glass fragments were determined using particle-induced X-ray emission (PIXE) spectrometry. The trace element concentrations for calcium, iron, manganese, strontium, and titanium are compared to those obtained by inductively-coupled plasma-atomic emission spectrometry (ICP-AES) following complete digestion by hydrofluoric acid. For these five elements, the absolute concentrations obtained by both methods are shown to agree well over a wide range of concentrations. The limits of detection for trace elements are typically lower for the ICP-AES method. However, we show that the concentrations of these five elements can be accurately measured by the PIXE method. Since PIXE is an entirely non-destructive method, there exists a niche for this technique to be used as a complement to the more sensitive ICP-AES technique in the forensic analysis of sheet glass.

  20. PIXE analysis of ancient Chinese Qing dynasty porcelain

    Science.gov (United States)

    Cheng, Huansheng; He, Wenquan; Tang, Jiayong; Yang, Fujia; Wang, Jianhua

    1996-09-01

    The major and minor chemical compositions and trace element content of white glaze made in Qing dynasty at kuan kiln have been determined by PIXE. Experimental results show that trace element contents RbSrZr are useful to distinguish the place of production of ancient porcelain. In the porcelain from different kilns situated in a same province, the trace element contents can be different from each other. Determining and comparing the major and minor compositions and trace elemental concentrations in white glaze by PIXE technique, we can distinguish a precious Qing dynasty porcelain made at kuan kiln from a fake.

  1. Theoretical detection limit of PIXE analysis using 20 MeV proton beams

    Science.gov (United States)

    Ishii, Keizo; Hitomi, Keitaro

    2018-02-01

    Particle-induced X-ray emission (PIXE) analysis is usually performed using proton beams with energies in the range 2∼3 MeV because at these energies, the detection limit is low. The detection limit of PIXE analysis depends on the X-ray production cross-section, the continuous background of the PIXE spectrum and the experimental parameters such as the beam currents and the solid angle and detector efficiency of X-ray detector. Though the continuous background increases as the projectile energy increases, the cross-section of the X-ray increases as well. Therefore, the detection limit of high energy proton PIXE is not expected to increase significantly. We calculated the cross sections of continuous X-rays produced in several bremsstrahlung processes and estimated the detection limit of a 20 MeV proton PIXE analysis by modelling the Compton tail of the γ-rays produced in the nuclear reactions, and the escape effect on the secondary electron bremsstrahlung. We found that the Compton tail does not affect the detection limit when a thin X-ray detector is used, but the secondary electron bremsstrahlung escape effect does have an impact. We also confirmed that the detection limit of the PIXE analysis, when used with 4 μm polyethylene backing film and an integrated beam current of 1 μC, is 0.4∼2.0 ppm for proton energies in the range 10∼30 MeV and elements with Z = 16-90. This result demonstrates the usefulness of several 10 MeV cyclotrons for performing PIXE analysis. Cyclotrons with these properties are currently installed in positron emission tomography (PET) centers.

  2. The proton induced X-ray emission (PIXE) for the quantitative analysis of elements in thin samples, in surface layers of thick samples, and in aerosol filters

    International Nuclear Information System (INIS)

    Waetjen, U.

    1983-01-01

    The PIXE analysis method for the determination of elements in thick samples was investigated. The text of the present thesis is arranged under the following headings: physical fundamentals and measuring equipment, quantitative analysis of thin samples, matrix effects at the PIXE analysis of thick samples, matrix correction methods, analysis of 'infinite thick' model substances, PIXE analysis of aerosol filters. (GSCH)

  3. Atmospheric environment measurement 3. Environmental pollution monitoring system using PIXE analysis

    International Nuclear Information System (INIS)

    Ishii, Keizo

    2009-01-01

    The PIXE(Proton Induced X-ray Emission) method is used in various fields owing to its high sensitivity. This method can be used to analyze multiple elements in a short time and therefore is suitable for the analysis of large quantities of environmental samples. We researched the effect of removing footwear in a room on indoor aerosol pollution. The concentration of aerosol particles in the case that footwear was not removed was 5 times larger than in the case when footwear was removed. We were able to identify a source of air pollution using both the results of PIXE analysis and information on wind direction. We applied PIXE analysis to investigate airborne yellow sand, which originals from the Gobi desert. By analyzing each yellow sand particle, hazardous yellow sand could be detected. We also applied PIXE analysis to river water pollution. River water samples were collected at a number of points along a river. The dilution of metallic elements by the river water was observed. Thus, it was shown that monitoring systems using the PIXE method are very useful for monitoring environmental pollution. (author)

  4. Microprobe PIXE analysis and EDX analysis on the brain of patients with Alzheimer's disease

    International Nuclear Information System (INIS)

    Yumoto, S.; Horino, Y.; Mokuno, Y.; Fujii, K.; Kakimi, S.; Mizutani, T.; Matsushima, H.; Ishikawa, A.

    1996-01-01

    To investigate the cause of Alzheimer's disease (senile dementia of Alzheimer's disease type), we examined aluminium (Al) in the brain (hippocampus) of patients with Alzheimer's disease using heavy ion (5 MeV Si 3+ ) microprobe particle-induced X-ray emission (PIXE) analysis. Heavy ion microprobes (3 MeV Si 2+ ) have several times higher sensitivity for Al detection than 2 MeV proton microprobes. We also examined Al in the brain of these patients by energy dispersive X-ray spectroscopy (EDX). (1) Al was detected in the cell nuclei isolated from the brain of patients with Alzheimer's disease using 5 MeV Si 3+ microprobe PIXE analysis, and EDX analysis. (2) EDX analysis demonstrated high levels of Al in the nucleolus of nerve cells in frozen sections prepared from the brain of these patients. Our results support the theory that Alzheimer's disease is caused by accumulation of Al in the nuclei of brain cells. (author)

  5. Radiation damage of paper samples in in-air PIXE analysis

    International Nuclear Information System (INIS)

    Matsuyama, S.; Endo, H.; Ishii, K.; Yamazaki, H.; Tokai, Y.; Sugimoto, A.; Yamamoto, K.; Satoh, T.; Orihara, H.

    1999-01-01

    Degradation of paper caused by beam irradiation was investigated from a viewpoint of discoloration in PIXE analysis and its application to the paper samples of archaeology. Two types of paper (Japanese paper and fine quality paper) were tested in in-air PIXE analysis with 3 MeV protons. The degree of discoloration was quantitatively measured by the use of a colorimeter. The degree of discoloration was different for each tested paper and corresponded to the radiation dose of ions. It is resulted that even the in-air PIXE analysis should be carefully applied to archaeological treasures. Because discoloration of all tested paper decreased gradually at first but then increased after a few weeks. However, this phenomenon can be used to develop a technique of funny coloration. (author)

  6. Radiation damage of paper samples in in-air PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, S.; Endo, H.; Ishii, K.; Yamazaki, H.; Tokai, Y.; Sugimoto, A.; Yamamoto, K.; Satoh, T. [Department of Quantum Science and Energy Engineering, Tohoku University, Sendai, Miyagi (Japan); Orihara, H. [Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center

    1999-07-01

    Degradation of paper caused by beam irradiation was investigated from a viewpoint of discoloration in PIXE analysis and its application to the paper samples of archaeology. Two types of paper (Japanese paper and fine quality paper) were tested in in-air PIXE analysis with 3 MeV protons. The degree of discoloration was quantitatively measured by the use of a colorimeter. The degree of discoloration was different for each tested paper and corresponded to the radiation dose of ions. It is resulted that even the in-air PIXE analysis should be carefully applied to archaeological treasures. Because discoloration of all tested paper decreased gradually at first but then increased after a few weeks. However, this phenomenon can be used to develop a technique of funny coloration. (author)

  7. Analysis of bone marrow stromal cell transferred bacterial {beta}-galactosidase gene by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Kumakawa, Toshiro [Tokyo Metropolitan Geriatric Hospital, Tokyo (Japan). Dept. of Blood Transfusion and Hematology; Hibino, Hitoshi; Tani, Kenzaburo; Asano, Shigetaka; Futatugawa, Shouji; Sera, Kouichiro

    1997-12-31

    PIXE, Particle Induced X-ray Emission, is a powerful, multi-elemental analysis method which has many distinguishing features and has been used in varies research fields. Recently the method of applying baby cyclotrons for nuclear medicine to PIXE has been developed. This enables us to study biomedical phenomena from the physical point of view. Mouse bone marrow stromal cells were transferred bacterial {beta}-galactosidase gene (LacZ gene) by murine retroviral vectors. Analysis of the bone marrow stromal cells with the LacZ gene by PIXE revealed remarkable changes of intracellular trace elements compared with the normal control cells. These results indicate that gene transfer by retroviral vectors may bring about a dynamic change of intracellular circumstances of the target cell. (author)

  8. PIXE analysis of nephrite minerals from different deposits

    Science.gov (United States)

    Zhang, Z. W.; Gan, F. X.; Cheng, H. S.

    2011-02-01

    External-beam PIXE was used to determine the major, minor and trace elements of 45 nephrite minerals from 14 different deposits, including China and other countries. Depending on the R∗ value (mole percent of Mg 2+/(Mg 2+ + Fe 2+(3+))) and content of Cr, Co and Ni, two types of nephrite minerals from dolomite and serpentinized ultramafic deposits can be more accurately distinguished. Besides, the nephrite minerals from Xiaomeiling and Wenchuan deposit can be distinguished with others from dolomite deposits, through the content of Sr and Mn/Fe value, respectively. Moreover, depending on the Sr content, clear evidence was given to prove that the raw materials of ancient nephrite artifacts from Liangzhu culture ruins are not from Xiaomeiling nephrite deposit. Furthermore, PIXE as a non-destructive method will be more used to study ancient nephrite artifacts, so these results can provide scientific basis for seeking the provenance of nephrite raw materials.

  9. PIXE analysis of chinese chicken-blood stone

    International Nuclear Information System (INIS)

    Lin, E.K.; Wang, C.W.; Yu, Y.C.; Liu, T.Y.; Cheng, H.S.; Zhu, H.X.; Yang, H.J.

    1999-01-01

    This paper reports the chemical compositions of chicken-blood stone Ji Xue Shi measured by Proton Induced X-ray Emission (PIXE). The experimental result show that for the red portion of chicken-blood stone, the concentration of Hg is as high as 20 wt%, and the concentration of S can be above 10 wt%. For the non-red portion the main chemical compositions are Al 2 O 3 and SiO 2 . The obtained chemical compositions are close to those of kaolinite for Balin chicken-blood stone, and of pyrophyllite for Changhua chicken-blood stone, respectively. So far many Changhua chicken-blood stones and Balin chicken-blood stones were found in China, the PIXE method can be used to explore the provenance of available chicken-blood stones. (author)

  10. Elemental analysis of gold coins by particle induced X-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Ferreira, G.P.; Gil, F.B.

    1981-01-01

    A Van de Graaff accelerator of 2 MeV energy was used for quantitative analysis of gold coins of the eighteenth and nineteenth centuries by the PIXE method. The results reproduce well the known legal title of the coins. However, for confirmation, a small set of Au-Ag-Cu and Au-Cu standards was also analysed. Again, the known composition of the standards was reasonably reproduced. In this way the authors think that the PIXE method is quite adequate for absolutely non-destructive analysis of gold alloy artifacts with no need of standards. (author)

  11. A new mapping acquisition and processing system for simultaneous PIXE-RBS analysis with external beam

    International Nuclear Information System (INIS)

    Pichon, L.; Beck, L.; Walter, Ph.; Moignard, B.; Guillou, T.

    2010-01-01

    The combination of ion beam analysis techniques is particularly fruitful for the study of cultural heritage objects. For several years, the AGLAE facility of the Louvre laboratory has been implementing these techniques with an external beam. The recent set-up permits to carry out PIXE, PIGE and RBS simultaneously on the same analyzed spot with a particle beam of approximately 20 μm diameter. A new mapping system has been developed in order to provide elemental concentration maps from the PIXE and RBS spectra. This system combines the Genie2000 spectroscopy software with a homemade software that creates maps by handling acquisition with the object position. Each pixel of each PIXE and RBS maps contains the spectrum normalised by the dose. After analysing each pixel of the PIXE maps (low and high energy X-ray spectra) with the Gupixwin peak-fitting software, quantitative elemental concentrations are obtained for the major and trace elements. This paper presents the quantitative elemental maps extracted from the PIXE spectra and the development of RBS data processing for light element distribution and thin layer characterization. Examples on rock painting and lustrous ceramics will be presented.

  12. Building a fingerprint database for modern art materials: PIXE analysis of commercial painting and drawing media

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, A., E-mail: alessandro.zucchiatti@uam.es [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Madrid (Spain); Climent-Font, A. [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Madrid (Spain); Departamento de Física Aplicada, Universidad Autónoma de Madrid, Avda. Francisco Tomás y Valiente 7, 28049 Madrid (Spain); Gómez-Tejedor, J. García [Museo Nacional Centro de Arte Reina Sofia, Departamento de Restauración, Calle Santa Isabel, 52, 28012 Madrid (Spain); Martina, S. [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Madrid (Spain); Universitá degli Studi di Torino, Turin (Italy); Muro García, C.; Gimeno, E.; Hernández, P.; Canelo, N. [Museo Nacional Centro de Arte Reina Sofia, Departamento de Restauración, Calle Santa Isabel, 52, 28012 Madrid (Spain)

    2015-11-15

    We have examined by PIXE (and by RBS in parallel) about 180 samples of commercial painting and drawing media including pencils, pastels, waxes, inks, paints and paper. Given the high PIXE sensitivity we produced X-ray spectra at low collected charges and currents, operating in good conservation conditions. For drawing media containing inorganic components or a unique marker element, we have defined colouring agent fingerprints which correspond, when applicable, to the composition declared by the manufacturer. For thin layers, the ratios of areal densities of elements are close to those expected given the declared composition, which is promising from the perspective of compiling the database. The quantitative PIXE and RBS analysis of part of the set of samples is provided.

  13. PIXE and neutron activation analysis: intercomparison in the elemental concentration of airborne particulate matter

    International Nuclear Information System (INIS)

    Cassorla, V.; Rojas, X.; Gras, N.; Chuaqui, L.; Dinator, M.I.; Morales, J.R.; Llona, F.; Romo-Kroeger, C.

    1993-01-01

    Two nuclear analytical techniques, neutron activation analysis (NAA) and proton induced X-ray emission (PIXE), were used to determine major and trace elements in airborne particulate matter collected during the first fortnight of June 1991 at the La Reina Nuclear Center. NAA detected the presence of 15 elements in the samples. PIXE, for the same samples, allowed the detection of 12 elements. The elements determined by both techniques were Al, Ca, Mn, Fe, Cu, and Zn. A good correlation between results for these elements for each of the two techniques was demonstrated. (author)

  14. Comparative study between the PIXE technique and neutron activation analysis for Zinc determination

    International Nuclear Information System (INIS)

    Cruvinel, Paulo Estevao; Crestana, Silvio; Artaxo Netto, Paulo Eduardo

    1997-01-01

    This work presents a comparative study between the PIXE, proton beams and neutron activation analysis (NAA) techniques, for determination of total zinc concentration. Particularly, soil samples from the Pindorama, Instituto Agronomico de Campinas, Sao Paulo State, Brazil, experimental station have been analysed and measuring the zinc contents in μg/g. The results presented good correlation between the mentioned techniques. The PIXE and NAA analyses have been carried out by using the series S, 2.4 MeV proton beams Pelletron accelerator and the IPEN/CNEN-IEA-R1 reactor, both installed at the Sao Paulo - Brazil university

  15. Proton induced X-ray emission (PIXE) analysis at Lucas Heights

    International Nuclear Information System (INIS)

    Cohen, D.; Duerden, P.

    1979-02-01

    The state of the proton induced X-ray emission (PIXE) work at Lucas Heights is reported together with a full description of the experimental arrangement and its use for analysis of trace elements (Z >or= 14). The fundamentals of PIXE are examined in detail with a view to understanding not only the background continuum but also the X-ray production mechanisms. Quantitative predictions for the number of X-rays detected after proton bombardment of the target have been made and these compare well with experiments

  16. Non-destructive analysis and appraisal of ancient Chinese porcelain by PIXE

    International Nuclear Information System (INIS)

    Cheng, H.S.; Zhang, Z.Q.; Xia, H.N.; Jiang, J.C.; Yang, F.J.

    2002-01-01

    This paper reports the results of the PIXE analysis on ancient Chinese blue and white porcelain fired at Kuan Kiln (Jingdezhen, Jiangxi province) during 13-19th century. The major, minor and trace element of porcelain body, white glaze and blue glaze were determined by PIXE. In this paper the chemical compositions of porcelain body, white glaze and blue glaze measured from Yuan (AD 1206-1368), Ming (AD 1368-1644) and Qing (AD 1616-1911) blue and white porcelain are present. The cobalt blue pigment used in Yuan, Ming and Qing are also discussed

  17. Non-destructive analysis and appraisal of ancient Chinese porcelain by PIXE

    Science.gov (United States)

    Cheng, H. S.; Zhang, Z. Q.; Xia, H. N.; Jiang, J. C.; Yang, F. J.

    2002-05-01

    This paper reports the results of the PIXE analysis on ancient Chinese blue and white porcelain fired at Kuan Kiln (Jingdezhen, Jiangxi province) during 13-19th century. The major, minor and trace element of porcelain body, white glaze and blue glaze were determined by PIXE. In this paper the chemical compositions of porcelain body, white glaze and blue glaze measured from Yuan (AD 1206-1368), Ming (AD 1368-1644) and Qing (AD 1616-1911) blue and white porcelain are present. The cobalt blue pigment used in Yuan, Ming and Qing are also discussed.

  18. PIXE: early NAA revisited

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1982-01-01

    A short, comparative evaluation of the methods of neutron activation analysis (NAA), and particle induced X-ray emission (PIXE), is given based on the Proc. of the 2nd international conference on PIXE and its analytical applications. The conference took place June 9-12, 1980, Lund, Sweden. 'The PIXE people have paralleled NAA people - in work, problems and mistakes, summarises the author, but PIXE was proved and established as a standard analytical method.' The method has proved extremely valuable in microprobe applications. (Sz.J.)

  19. Analysis of desert rose using PIXE and RBS techniques

    International Nuclear Information System (INIS)

    Al-Kofahi, M.M.; Hallak, A.B.; Al-Juwair, H.A.; Saafin, A.K.

    1993-01-01

    Particle-induced x-ray emission (PIXE) and Rutherford backscattering spectrometry (RBS) were used to analyse desert rose geological samples. Samples from the rose core and from the rose peripherals were studied. All samples were found to contain C, N, O, Na, Mg, Si, S, Cl, K, Ca, Ti, Mn, Fe and Sr. Core samples were found to contain more silicon than peripheral samples. The extra silicon in the rose core may suggest a mechanism for the formation of the rose through crystal growth on a seed of silicon. (author)

  20. PIXE-PIGE analysis of late roman glass fragments

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Tubio, B. [Departamento de Fisica Aplicada III, Escuela de Ingenieros, Universidad de Sevilla, Camino de los Descubrimientos s/n, 41092 Sevilla (Spain)]. E-mail: tubio@us.es; Ontalba Salamanca, M.A. [Departamento de Fisica, Escuela Politecnica, Universidad de Extremadura, Avda. de la Universidad s/n, 10071 Caceres (Spain); Ortega-Feliu, I. [Centro Nacional de Aceleradores, Universidad de Sevilla, Avda. Thomas A. Edison s/n, 41092 Sevilla (Spain); Respaldiza, M.A. [Centro Nacional de Aceleradores, Universidad de Sevilla, Avda. Thomas A. Edison s/n, 41092 Sevilla (Spain); Amores Carredano, F. [Departamento de Prehistoria y Arqueologia, Universidad de Sevilla, C/Dona Maria de Padilla s/n, 41010 Sevilla (Spain); Gonzalez-Acuna, D. [Departamento de Geografia, Historia y Filosofia, Universidad Pablo de Olavide, Ctra. de Utrera Km 1, 41013 Sevilla (Spain)

    2006-08-15

    A set of Roman glass fragments, excavated at Sevilla and dated in the 5th century A.D., has been analysed by PIXE and PIGE techniques using the external beam set-up of the 3 MV tandem Pelletron accelerator of the CNA at the University of Sevilla. Using a simple quantification method, based on the indirect charge calculation on the sample by monitoring the X-ray induced by the proton beam on the exit window, the composition of the glasses has been determined. From the obtained results, the use of soda as flux has been inferred and colouring manufacture procedures have been identified.

  1. PIXE analysis of fish otoliths. Application to fish stock discrimination

    International Nuclear Information System (INIS)

    Arai, Nobuaki; Sakamoto, Wataru; Tateno, Koji; Yoshida, Koji.

    1996-01-01

    PIXE was adopted to analyze trace elements in otoliths of Japanese flounder to discriminate among several local fish stocks. The otoliths were removed from samples caught at five different sea areas along with the coast of the Sea of Japan: Akita, Ishikawa, Kyoto (2 stations), and Fukuoka. Besides calcium as main component, strontium, manganese, and zinc were detected. Especially Sr concentrations were different among 4 areas except between 2 stations in Kyoto. It suggested that the fish in the 2 stations in Kyoto were the same stock differed to the others. (author)

  2. Bronze analysis by k0-NAA and PIXE

    International Nuclear Information System (INIS)

    Arana, G.; Waetjen, U.; Ingelbrecht, C.; Robouch, P.

    2003-01-01

    Five copper alloys were prepared with modern powder metallurgical processes in the frame of the European project 'Improvement of Means of Measurement on Archaeological Copper-Alloys for Characterisation and Conservation (IMMACO)' and certified for As, Pb, Sn and Zn mass fractions. Similar in their composition to archaeological bronze alloys, these Certified Reference Materials (CRMs) are to be used for calibration of XRF instruments for characterization of archaeological samples either in the laboratory or in the field. Successful contribution of non-destructive analytical methods (k 0 -NAA and PIXE) to the IMMACO project and to the certification of the five reference materials is presented. (author)

  3. Elemental analysis of Uranouchi bay seabed sludge using PIXE

    International Nuclear Information System (INIS)

    Kabir, M. Hasnat; Narusawa, Tadashi; Nishiyama, Fumitaka; Sumi, Katsuhiro

    2006-01-01

    Elemental analyses were carried out for the seabed sludge collected from Uranouchi bay (Kochi, Japan) using Particle Induced X-ray Emission (PIXE). Seabed-sludge contamination with heavy metals as well as toxic elements becomes one of the most serious environmental problems. The aim of the present study is to investigate the polluted areas in the bay by heavy and toxic elements. As a results of analyses of samples collected from eleven different places in the bay, seventeen elements including toxic ones were detected. The results suggest that the center region of the bay is seriously contaminated by heavy and toxic elements in comparison with the other areas in the bay. (author)

  4. Quantitative analysis of ancient Egyptian pigments by external PIXE

    International Nuclear Information System (INIS)

    Uda, M.; Tsunokami, T.; Murai, R.; Maeda, K.; Harigai, I.; Nakayama, Y.; Yoshimura, S.; Kikuchi, T.; Sakurai, K.; Sasa, Y.

    1993-01-01

    Pigments painted on Egyptian excavations in the 18th Dynasty were analyzed successfully by external PIXE with the aid of the X-ray diffraction. A white pigment was composed on Mg 3 Ca(CO 3 ) 4 ; red: αFe 2 O 3 , αFeO.OH and AsS; pink: Mixtures of white and red pigments; yellow: αFeO.OH and As 2 S 3 ; and blue: CaO.CuO.4SiO 2 . (orig.)

  5. An indirect method to measure the electric charge deposited on insulators during PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dinator, M.I.; Cancino, S.A.; Miranda, P.A. [Departamento de Fisica, Facultad de Ciencias, Universidad de Chile, Las Palmeras 3425, Nunoa, Santiago (Chile); Morales, J.R. [Departamento de Fisica, Facultad de Ciencias, Universidad de Chile, Las Palmeras 3425, Nunoa, Santiago (Chile)], E-mail: rmorales@uchile.cl; Seelenfreund, A. [Universidad Academia de Humanismo Cristiano, Condell 343, Providencia, Santiago (Chile)

    2007-10-15

    Total charge deposited by a proton beam in an insulator during PIXE analysis has been indirectly determined using a Mylar film coated with cobalt. Elemental concentrations in the samples, pieces of volcanic glass, were obtained and compared to concentrations determined by ICP OES on the same samples. The strong agreement between these results shows the accuracy of the charge determined by this method.

  6. Pixe analysis of trace elements in tissues of rats treated with anticonvulsants

    Science.gov (United States)

    Hurd, R. W.; Van Rinsvelt, H. A.; Kinyua, A. M.; O'Neill, M. P.; Wilder, B. J.; Houdayer, A.; Hinrichsen, P. F.

    1987-04-01

    Several lines of evidence implicate metals in epilepsy. Anticonvulsant drugs are noted to alter levels of metals in humans and animals. PIXE analysis was used to investigate effects of three anticonvulsant drugs on tissue and brain cortex trace elements. The content of zinc and copper was increased in liver and spleen of rats treated with anticonvulsants while selenium was decreased in cortex.

  7. PIXE analysis of trace elements in tissues of rats treated with anticonvulsants

    Energy Technology Data Exchange (ETDEWEB)

    Hurd, R.W.; Van Rinsvelt, H.A.; Kinyua, A.M.; O' Neill, M.P.; Wilder, B.J.; Houdayer, A.; Hinrichsen, P.F.

    1987-04-01

    Several lines of evidence implicate metals in epilepsy. Anticonvulsant drugs are noted to alter levels of metals in humans and animals. PIXE analysis was used to investigate effects of three anticonvulsant drugs on tissue and brain cortex trace elements. The content of zinc and copper was increased in liver and spleen of rats treated with anticonvulsants while selenium was decreased in cortex.

  8. PIXE analysis of trace elements in tissues of rats treated with anticonvulsants

    International Nuclear Information System (INIS)

    Hurd, R.W.; Van Rinsvelt, H.A.; Kinyua, A.M.; O'Neill, M.P.; Wilder, B.J.; Florida Univ., Gainesville; Houdayer, A.; Hinrichsen, P.F.

    1987-01-01

    Several lines of evidence implicate metals in epilepsy. Anticonvulsant drugs are noted to alter levels of metals in humans and animals. PIXE analysis was used to investigate effects of three anticonvulsant drugs on tissue and brain cortex trace elements. The content of zinc and copper was increased in liver and spleen of rats treated with anticonvulsants while selenium was decreased in cortex. (orig.)

  9. Status of data and data needs for XRF and PIXE based element analysis

    International Nuclear Information System (INIS)

    Kapoor, S.S.; Choudhary, R.K.

    1986-01-01

    The status of data and data needs for X-ray fluorescence (XRF) and particle induced X-ray (PIXE) are examined to determine the areas where additional and improved data are required to improve the accuracy, precision and sensitivity of quantitative element analysis by the above techniques. (author)

  10. PIXE analysis of historical paintings: Is the gain worth the risk?

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); PSL Research University, Chimie ParisTech – CNRS, Institut de Recherche Chimie Paris, UMR8247, 75005 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS – Ministère de la Culture – IRCP, Palais du Louvre, 75001 Paris (France); Gonzalez, V. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); PSL Research University, Chimie ParisTech – CNRS, Institut de Recherche Chimie Paris, UMR8247, 75005 Paris (France); Pichon, L. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS – Ministère de la Culture – IRCP, Palais du Louvre, 75001 Paris (France)

    2015-11-15

    The PIXE analysis of easel paintings constitutes a challenging task. Despite recognized merits and a few emblematic applications, PIXE has never been routinely applied to these fragile, complex and precious targets. The present work discusses the place of PIXE in the study of easel paintings and opens up perspectives for a more systematic usage of this analytical technique. Progress achieved since decades in the implementation of PIXE to study such fragile cultural heritage artefacts is reviewed, notably at the LABEC laboratory in Italy and at the AGLAE facility of the C2RMF in France. Two specific techniques developed for paintings are detailed and exemplified on Renaissance painting masterpieces: differential PIXE for paint layers depth profiling and multi-scale elemental mapping for the imaging of pigment distribution. Beam-induced damage, a major concern, notably depends on the employed beam fluence in particle/cm{sup 2} or μC/cm{sup 2}. After recalling previous works on damage induced in chemical products comparable to pigments, we present the behaviour under different fluences of protons of a few MeV (1–300 μC/cm{sup 2}) of targets having high resemblance to historical easel paintings: pellets of specially synthesized lead white pigments, layers of lead white mixed with linseed oil and areas containing lead white of two 19th century paintworks. The results shed new lights on the behaviour of paintworks under the beam and pave the way to strategies for damage mitigation. In particular, the lowering of PIXE performance induced by the decrease of the beam fluence sets a trade-off between risk of damage and gained information which also impacts the PIXE scanning protocol for paintings. As an illustration of an adequate adjustment of this balance, we report the exploratory application of PIXE mapping to a large area of a 19th century easel painting without damage. The recorded elemental maps are compared to elemental maps collected on the same area using

  11. PIXE Analysis and source identification of airborne particulate matter collected in Downtown Havana City

    International Nuclear Information System (INIS)

    Perez, G.; Pinnera, I; Ramos, M; Guibert, R; Molina, E.; Martinez, M.; Fernandez, A.; Aldape, F.; Flores, M.

    2009-01-01

    A set of samples containing airborne particulate matter (in two particle size fraction PM10 and PM2,5) collected during five months from November 2006 to April 2007 in a urban area of Havana City were analyzed by Particle-Induced X-ray Emission (PIXE) technique and the concentrations of 14 elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br and Pb) were determined consistently in both particle size fractions with minimum detection limits in the range of ng/m3. A Gent air sampler was used for the aerosol collection in PM10 and PM2,5 particles simultaneously and the PIXE elemental analysis were performed using a proton beam of 2.5 MeV from the 2 MV Van de Graff Tandetron Accelerator at the ININ PIXE Laboratory in Mexico. The analytical database provided by PIXE was statistically analyzed in order to determine the promising local pollution sources. The statistical techniques of Multivariate Factor Analysis in combination with the Principal Component Analysis methods were applied to this data and allowed identifying five main pollution sources of airborne particulate matter (PM10 and PM2,5) collected in this area. The main (local) identified sources were: soil dust, sea spray, industry, fossil fuel combustion from motor vehicles and burnings or incinerations of diverse materials. A general discussion about these results is presented in this work. (Author)

  12. Improvements in PIXE analysis of hourly particulate matter samples

    Energy Technology Data Exchange (ETDEWEB)

    Calzolai, G., E-mail: calzolai@fi.infn.it [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Lucarelli, F. [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Chiari, M.; Nava, S. [National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Giannoni, M. [National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Department of Chemistry, University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino (Italy); Carraresi, L. [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Prati, P. [Department of Physics, University of Genoa and INFN Division of Genoa, Via Dodecaneso 33, 16146 Genoa (Italy); Vecchi, R. [Department of Physics, Università degli Studi di Milano and INFN Division of Milan, Via Celoria 16, 20133 Milan (Italy)

    2015-11-15

    Most air quality studies on particulate matter (PM) are based on 24-h averaged data; however, many PM emissions as well as their atmospheric dilution processes change within a few hours. Samplings of PM with 1-h resolution can be performed by the streaker sampler (PIXE International Corporation), which is designed to separate the fine (aerodynamic diameter less than 2.5 μm) and the coarse (aerodynamic diameter between 2.5 and 10 μm) fractions of PM. These samples are efficiently analyzed by Particle Induced X-ray Emission (PIXE) at the LABEC laboratory of INFN in Florence (Italy), equipped with a 3 MV Tandetron accelerator, thanks to an optimized external-beam set-up, a convenient choice of the beam energy and suitable collecting substrates. A detailed description of the adopted set-up and results from a methodological study on the detection limits for the selection of the optimal beam energy are shown; the outcomes of the research on alternative collecting substrates, which produce a lower background during the measurements, and with lower contaminations, are also discussed.

  13. PIXE-PIGE analysis of some Indian medicinal plants

    Science.gov (United States)

    Nomita Devi, K.; Nandakumar Sarma, H.

    2010-06-01

    The quantitative estimation of various trace element concentrations in medicinal plants is necessary for determining their effectiveness in treating various diseases and for understanding their pharmacological action. Elemental concentrations of some selected medicinal plants of north east India was measured by proton induced X-ray emission (PIXE) and proton induced γ-ray emission (PIGE) techniques. PIXE measurements were carried out using 2.4 MeV collimated protons from the 3 MV tandetron accelerator of NCCCM, Hyderabad (India) while the PIGE measurements were carried out using 3 MeV protons from the same accelerator in the same laboratory. Accuracy and precision of the techniques were assured by analyzing certified reference materials in the same experimental conditions. Various elements of biological importance in man's metabolism were found to be present in varying concentrations in the studied medicinal plants and no toxic heavy metals were detected. The concentration of the various elements in the medicinal plants and their role in treating various diseases are discussed.

  14. PIXE-PIGE analysis of some Indian medicinal plants

    Energy Technology Data Exchange (ETDEWEB)

    Nomita Devi, K., E-mail: nomita_k@rediffmail.co [Department of Physics, Manipur University, Canchipur, Imphal 795003 (India); Nandakumar Sarma, H. [Department of Physics, Manipur University, Canchipur, Imphal 795003 (India)

    2010-06-15

    The quantitative estimation of various trace element concentrations in medicinal plants is necessary for determining their effectiveness in treating various diseases and for understanding their pharmacological action. Elemental concentrations of some selected medicinal plants of north east India was measured by proton induced X-ray emission (PIXE) and proton induced {gamma}-ray emission (PIGE) techniques. PIXE measurements were carried out using 2.4 MeV collimated protons from the 3 MV tandetron accelerator of NCCCM, Hyderabad (India) while the PIGE measurements were carried out using 3 MeV protons from the same accelerator in the same laboratory. Accuracy and precision of the techniques were assured by analyzing certified reference materials in the same experimental conditions. Various elements of biological importance in man's metabolism were found to be present in varying concentrations in the studied medicinal plants and no toxic heavy metals were detected. The concentration of the various elements in the medicinal plants and their role in treating various diseases are discussed.

  15. Nigerian coal analysis by PIXE and HEBS techniques

    International Nuclear Information System (INIS)

    Olabanji, S.O.

    1989-05-01

    PIXE and HEBS techniques were employed for the measurement of the concentrations of the major, minor and trace elements in Nigerian coal samples from a major deposit. The samples were irradiated with 2.55 MeV protons from the 3 MeV tandem accelerator (NEC 3 UDH) in Lund. The PIXE results are reported and compared with an earlier work on Nigerian coal using FNAA and INAA analytical techniques while the HEBS results are compared with ASTM previous results. The results corroborate the assertion that Nigerian coals are of weak and noncoking grades with low sulphur (0.82-0.99%) and relatively high hydrogen (4.49-5.16%) contents. The motivation for this work is partly due to the projected usage of coal as metallurgical feedstocks and as fuel, and partly because of the genuine concern about the concomitant environmental effects of the increased burning of coal. The knowledge of the concentration of all elements is important for the characterization of coal and the determination and control of its products. Economic parameters such as the ash contents and calorific values are associated with the concentrations of coal's constituents. (author). 11 refs, 1 fig., 4 tabs

  16. SIMION, Electrostatic Lens Analysis and Design

    International Nuclear Information System (INIS)

    Dahl, David A.

    2001-01-01

    1 - Description of program or function: SIMION is an electrostatic lens analysis and design program. In SIMION an electrostatic lens is defined as a two-dimensional electrostatic potential array containing both electrode and non-electrode points. The potential array is refined using over-relaxation methods allowing voltage contours and ion trajectories to be computed and plotted. Planar and cylindrical symmetry assumptions allow the two-dimensional fields to support three-dimensional ion trajectory calculations. In addition, the user has the option of writing simple programs which can among other actions control field scale factors, dynamically adjust electrodes, and define explicit three-dimensional field functions (e.g. a quadrupole) used in lieu of array fields in specified portions of the potential array. Magnetic fields can be specified for computing ion trajectories in many electrostatic and magnetic field environments. An interactive graphics interface that uses a high resolution color display and mouse allows the user to view electrodes, trajectories, and contours on the screen prior to plotting, and a memory zoom feature permits expansion of selected areas in the current view. The mouse can be operated to edit the potential array, initialize voltage gradients, or resize the potential array. 2 - Method of solution: SIMION is designed to model the electrostatic fields and forces created by a collection of shaped electrodes given certain symmetry assumptions. The electrostatic fields are modeled as boundary value problem solutions of a Laplace elliptical partial differential equation. A finite difference technique called dynamically self-adjusting over-relaxation is applied to the two-dimensional potential array of points representing electrode and non-electrode regions to obtain a best estimate of the voltages for those points within the array that depict non-electrode regions. A standard fourth-order Runge-Kutta method is used for numerical integration of

  17. A comparison of quantitative reconstruction techniques for PIXE-tomography analysis applied to biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Beasley, D.G., E-mail: dgbeasley@ctn.ist.utl.pt [IST/C2TN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Alves, L.C. [IST/C2TN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Barberet, Ph.; Bourret, S.; Devès, G.; Gordillo, N.; Michelet, C. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Le Trequesser, Q. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Institut de Chimie de la Matière Condensée de Bordeaux (ICMCB, UPR9048) CNRS, Université de Bordeaux, 87 avenue du Dr. A. Schweitzer, Pessac F-33608 (France); Marques, A.C. [IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Seznec, H. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Silva, R.C. da [IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal)

    2014-07-15

    The tomographic reconstruction of biological specimens requires robust algorithms, able to deal with low density contrast and low element concentrations. At the IST/ITN microprobe facility new GPU-accelerated reconstruction software, JPIXET, has been developed, which can significantly increase the speed of quantitative reconstruction of Proton Induced X-ray Emission Tomography (PIXE-T) data. It has a user-friendly graphical user interface for pre-processing, data analysis and reconstruction of PIXE-T and Scanning Transmission Ion Microscopy Tomography (STIM-T). The reconstruction of PIXE-T data is performed using either an algorithm based on a GPU-accelerated version of the Maximum Likelihood Expectation Maximisation (MLEM) method or a GPU-accelerated version of the Discrete Image Space Reconstruction Algorithm (DISRA) (Sakellariou (2001) [2]). The original DISRA, its accelerated version, and the MLEM algorithm, were compared for the reconstruction of a biological sample of Caenorhabditis elegans – a small worm. This sample was analysed at the microbeam line of the AIFIRA facility of CENBG, Bordeaux. A qualitative PIXE-T reconstruction was obtained using the CENBG software package TomoRebuild (Habchi et al. (2013) [6]). The effects of pre-processing and experimental conditions on the elemental concentrations are discussed.

  18. Elemental analysis of river sediments by PIXE and PIGE

    International Nuclear Information System (INIS)

    Kennedy, V.J.; Augusthy, A.; Varier, K.M.; Magudapathy, P.; Panchapakesan, S.; Nair, K.G.M.; Vijayan, V.

    1999-01-01

    The Chaliyar river, located in Kerala, India has shown preoccupying pollution levels, that constitute a threat to public health and the ecological system. PIXE and PIGE techniques have been employed to measure the elemental concentrations in the river sediment samples. Thick targets were prepared out of the sediment samples collected from various sites along the course of the river. The measurements were carried out using 3 MeV proton beam obtained from 3 MV Tandem pelletron accelerator at Institute of Physics, Bhubaneswar. The elemental concentrations, especially that of heavy metals, at different sites are discussed in detail. Our results show that sediments from a site where the industrial activities are high are significantly high in concentrations of heavy metals (Cr, Ni, Cu, Zn, Hg and Pb) than those collected from non-industrial sites. The measured values are compared with the average composition of unpolluted river sediments and other national and international river sediments. (author)

  19. PIXE analysis of proteins from a photochemical center

    Science.gov (United States)

    Solís, C.; Oliver, A.; Andrade, E.

    1998-03-01

    In oxygen evolving photosynthetic organisms, light is absorbed and its energy used for the conversion of chemical products in two photosystems: PSI and PSII. Each photosystem is composed of a protein core which binds a pigment antenna and a Reaction Center (RC). RC of PSI is considered an "Iron-Sulfur" type. There are six components that participate in the charge separation after light absorption occurs in PSI: the center chlorophyll P700, two acceptors A 0 and A 1 and three FeS centers F X, F A and F B. However, the exact number of polypeptides, their exact molecular weight, their relative abundances and the active components associated to those polypeptides remain still to be completely characterized. In particular the FeS centers have been difficult to detect in a direct way in a gel band, because the amount of centers involved is under the detection limits of the conventional techniques. This study has been under-taken to explore the capability of particle induced X-ray emission (PIXE) to detect in a qualitative way the presence of Fe in some of the protein bands obtained by Sodium Dodecyl Sulfate Polyacrylamide Gel Electrophoresis (SDS-PAGE) from the PSI complex. The complex was isolated from membranes of thermophilic cyanobacteria: Synechochoccus sp. The polyacrylamide gel electrophoresis of the complex shows eight subunits of 66, 60-65, 14, 13, 9, 8 and 7 KDa. In-air PIXE was performed at 2 MeV and proved to be an adequate tool for direct identification of the iron present in the gel bands.

  20. PIXE analysis of cave sediments, prehispanic paintings and obsidian cutting tools from Baja California Sur caves

    International Nuclear Information System (INIS)

    Miranda, J.; Oliver, A.; Dacal, A.; Ruvalcaba, J.L.; Cruz, F.; Ortiz, M.E.; Vinas, R.

    1993-01-01

    Elemental PIXE analysis of cave sediments, minerals, pigments of the prehispanic paintings and obsidian cutting tools from caves in Baja California Sur has been carried out with a 0.7 MeV proton beam. The elements analysed in this sample set (Al to Co) provide an idea of the environment of the caves. The obsidian data analysis suggests that the human communities who made these painting used more than one obsidian source to manufacture cutting tools. (orig.)

  1. Microprobe PIXE analysis and EDX analysis on the brain of patients with Alzheimer`s disease

    Energy Technology Data Exchange (ETDEWEB)

    Yumoto, S. [Tokyo Univ. (Japan). Faculty of Medicine; Horino, Y.; Mokuno, Y.; Fujii, K.; Kakimi, S.; Mizutani, T.; Matsushima, H.; Ishikawa, A.

    1996-12-31

    To investigate the cause of Alzheimer`s disease (senile dementia of Alzheimer`s disease type), we examined aluminium (Al) in the brain (hippocampus) of patients with Alzheimer`s disease using heavy ion (5 MeV Si{sup 3+}) microprobe particle-induced X-ray emission (PIXE) analysis. Heavy ion microprobes (3 MeV Si{sup 2+}) have several times higher sensitivity for Al detection than 2 MeV proton microprobes. We also examined Al in the brain of these patients by energy dispersive X-ray spectroscopy (EDX). (1) Al was detected in the cell nuclei isolated from the brain of patients with Alzheimer`s disease using 5 MeV Si{sup 3+} microprobe PIXE analysis, and EDX analysis. (2) EDX analysis demonstrated high levels of Al in the nucleolus of nerve cells in frozen sections prepared from the brain of these patients. Our results support the theory that Alzheimer`s disease is caused by accumulation of Al in the nuclei of brain cells. (author)

  2. PIXE (proton induced X-ray emission) analysis of caatinger

    International Nuclear Information System (INIS)

    Nakanishi, T.M.; Futatsugawa, Shoji; Sera, Kouichiro.

    1995-01-01

    Caatinger (Mimosa acutistipula Benth), which has been a popular wood among the people in north east part of Brazil, was analyzed using PIXE (proton induced X-ray emission). The wood sample was divided into three parts, center, inner and outer side of the wood. Using the wood slice of each part, Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, Mn, Fe, Cu, Zn, As, Se, Br, Rb, Sr, Y, Ru and Pb were detected. When the wood slices were decomposed with nitric acid, Co and Ni were able to be determined. Two samples, non-destructive and chemically treated sample, of heartwood and sapwood showed the similar concentration of the elements. There was a discrete change of the accumulated elements between heartwood and sapwood. Most of the elements detected tended to be concentrated at sapwood, whereas Ca, Cu and Sr were concentrated at heartwood. At center part, especially, Na, Mg, Fe and Sr were accumulated. Since most of the heartwood and sapwood is dead, discrete change of the element concentration suggests some element movement across the annual ring at heartwood formation. (author)

  3. PIXE analysis of western han dynasty ancient glasses unearthed in Yangzhou city

    International Nuclear Information System (INIS)

    Li Qinghui; Gu Donghong; Gan Fuxi; Zhang Bin; Ma Bo; Cheng Huansheng

    2003-01-01

    Chemical composition analysis is one of the most important research aspects to provide scientific proof for the technical origin and development of Chinese ancient glass. Proton induced X-ray emission (PIXE) technique is a kind of multi-element quantitative analysis method with high sensitivity and without destruction of samples. Chemical composition of the Western Han dynasty glass garment flakes, which were excavated from Yangzhou city, was analyzed by PIXE, quantitatively. It was found that these glass flakes were attributed to PbO-BaO-SiO 2 glass originated in China. These flakes all consist of a glass core and a corroded outer layer with different thickness. There are relatively higher PbO, P 2 O 5 and CaO, while much lower BaO and SiO 2 in the corroded layers than in the glass cores. The experimental results were discussed

  4. Comparative experimental study of PIXE and X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Vega B, L.R. De la.

    1994-01-01

    PIXE and X RF techniques are powerful analysis instruments in the determination of traces of elements. Although the physical processes characteristic X-rays production (ionization-emission) are similar in both methods, the representative background of each technique, responsible of its sensitivity, are different. This is because the interaction between exciter agents and the matter produces different effects. In PIXE, the background is caused by the radiation produced by the braking of the secondary electrons: Bremsstrahlung. In X RF, the background is due to the elastic and inelastic scattering of photons: Rayleigh and Compton effects. In this work, we have compared the results of the analysis of environmental samples using both methods, in order to know the scope of each one and develop them as complementary techniques. (Author)

  5. PIXE analysis of Moroccan architectural glazed ceramics of 14th-18th centuries

    International Nuclear Information System (INIS)

    Zucchiatti, A.; Azzou, A.; El Amraoui, M.; Haddad, M.; Bejjit, L.; Ait Lyazidi, S.

    2009-01-01

    The PIXE analysis of glazes and ceramic bodies of a set of architectural glazed ceramics (mostly the zellige mosaics), sampled from seven Moroccan monuments from the 14th to the 18th century AD, has been performed. We have identified high lead glazes, opacified with tin-oxide, laid over a calciferous body to produce hard tiles easy to chisel as required by the zellige technique. The analysis has revealed significant differences between the monuments examined: in particular in the formulation of the base glass and in the use of stains to produce coloured glazes. We observed the peculiarity of materials used in Marrakech and we could distinguish, both in terms of glazes and ceramic bodies, the two almost contemporary Madersas dedicated to the sultan Bou Inan, one in Meknes the other in Fez. The PIXE measurements integrate a broad range of spectrometric investigations performed in the past few years. (author)

  6. PIXE Analysis of Aerosol and Soil Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Joshua; Ali, Salina; Nadareski, Benjamin; Labrake, Scott; Vineyard, Michael

    2014-09-01

    We have performed an elemental analysis of aerosol and soil samples collected at Piseco Lake in Upstate New York using proton induced X-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the aerosol samples near Piseco Lake and distribute the particulate matter onto Kapton foils by particle size. The soil samples were also collected at Piseco Lake and pressed into cylindrical pellets for experimentation. PIXE analysis of the aerosol and soil samples were performed with 2.2-MeV proton beams from the 1.1-MV Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. There are higher concentrations of sulfur at smaller particle sizes (0.25-1 μm), suggesting that it could be suspended in the air for days and originate from sources very far away. Other elements with significant concentrations peak at larger particle sizes (1-4 μm) and are found in the soil samples, suggesting that these elements could originate in the soil. The PIXE analysis will be described and the resulting data will be presented.

  7. Pixe analysis of Cu,Zn,Hg and Cd in mussels samples in bay of Algiers

    International Nuclear Information System (INIS)

    Benamar, M.A.; Tchantchane, A.; Benouali, N.; Azbouche, A.; Tobbeche, S.

    1995-01-01

    The purpose of our work is the elaboration of and absolute technique for determination of trace elements in biological matrices by means of Pixe analysis. We are interested in the determination of heavy metals in mussels samples taken from differents sits of algies coast (Cu,Zn,Cd and Hg). The reason of our choise is the element toxicity and the possible contamination of the marine environment

  8. PIXE analysis of otoliths from reared red sea bream, pagrus major (temminck et schlegl)

    International Nuclear Information System (INIS)

    Arai, Nobuaki; Sakamoto, Wataru

    1993-01-01

    PIXE analysis was applied to estimate mineral concentration in red sea bream otoliths without cutting or polishing. Detected elements include Sr, Fe, Mn and Zn, which are commonly found in the otoliths in marine fishes. Strontium-Calcium concentration ratio is calculated by means of combined X-ray yields. The ratio doesn't indicate clear correlaion with mean reared seawater temperature. It is caused by the diffraction error induced by rough topographies of the otoliths surface. (author)

  9. PIXE Analysis of Atmospheric Aerosol Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Josh; Ali, Salina; Nadareski, Benjamin; Safiq, Alexandrea; Smith, Jeremy; Labrake, Scott; Vineyard, Michael

    2013-10-01

    We have performed an elemental analysis of atmospheric aerosol samples collected at Piseco Lake in Upstate New York using proton induced x-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the samples and distribute the particulate matter onto Kapton foils by particle size. The PIXE experiments were performed with 2.2-MeV proton beams from the 1.1-MV pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. X-Ray energy spectra were measured with a silicon drift detector and analyzed with GUPIX software to determine the elemental concentrations of the aerosols. A broad range of elements from silicon to zinc were detected with significant sulfur concentrations measured for particulate matter between 0.25 and 0.5 μm in size. The PIXE analysis will be described and preliminary results will be presented.

  10. Application of micro-PIXE analysis to investigate trace elements in deciduous teeth enamel

    International Nuclear Information System (INIS)

    Igari, K.; Takahashi, A.; Ando, H.

    2010-01-01

    The early life environment has widespread consequences for later health and disease. To prevent the disease in later life, the assessment of fetal environment is very important. In Japan, birthweight has fallen rapidly during recent two decades. The reduction of birthweight represents reduced fetal nutrition. Deciduous tooth enamel contains pre- and postnatal enamel and its chemical composition reflects the status of metabolism of trace elements during formation period. Deciduous tooth enamel is considered to be a suitable indicator of trace elements exposure in utero. We applied micro-PIXE analysis to investigate the trace elemental content in deciduous tooth enamel. Two deciduous canines from one healthy Japanese boy were used for this study. The enamel section including pre- and postnatal enamel was prepared for micro-PIXE analysis. Five trace elements (Na, Mg, Cl, Zn, and Sr) were detected in the scanning area of tooth. The distribution profiles of 5 elements were obtained as X-ray maps. The distribution profiles of zinc and chlorine were specific, and showed higher concentration in surface enamel. No elements showed different profiles of X-ray maps between pre- and postnatal enamel in this sample. The results of this study suggested that micro-PIXE analysis would be able to estimate the trace elements in prenatal and postnatal enamel, respectively. (author)

  11. MAPPIX: A software package for off-line micro-pixe single particle aerosol analysis

    International Nuclear Information System (INIS)

    Ceccato, D.

    2009-01-01

    In the framework of a multiannual experiment performed at Baia Terra Nova, Antarctica, size-segregated aerosol samples were collected by using a 12-stage SDI impactor (Hillamo design). Approximately 2800 particles, belonging to the first four supermicrometric SDI stages - 8.39, 4.08, 2.68, 1.66 μm dynamic aerosol diameter cuts - were analyzed at the INFN-LNL micro-PIXE facility, a three lens Oxford Microprobe (OM) product, installed in the early nineties. Four regions on each of the 12 sub-samples were measured; 60 aerosol particles were detected on average in each of the analyzed regions. The off-line single aerosol particle (SAP) analysis of such big amount of data required software that is able to rapidly handle the acquired data, with a simple and fast area selection procedure; the subsequent automated PIXE spectra analysis with a specialized code was also needed. The MAPPIX 2.0 software was designed to make easier and faster the user jobs during the SAP analysis. The package is composed of two separate routines: the first one is devoted to data format conversion (OM-LMF file format to MAPPIX format), while the second one is devoted to micro-PIXE maps graphical presentation and aerosol particle selection procedure. The MAPPIX data format and software features will be discussed; a short report of the speed performances will be presented.

  12. Application of PIXE analysis to study urban atmospheric aerosols from downtown Havana City

    International Nuclear Information System (INIS)

    Perez Zayas, Grizel; Pinnera Hernandez, Ibrahin; Ramos Aruca, Maridelin; Guibert Gala, Rolando; Molina Esquivel, Enrique; Martinez Varona, Miriam; Fernandez Arocha, Ariadna; Aldape Ugalde, Francisca; Flores Maldonado, Javier

    2010-01-01

    The present work reports, the results of a first study of elemental composition in airborne particulate matter (in fine and coarse particle size fractions) collected at the Atmospheric Monitoring Station in the Municipality of Centro Habana, using the Particle-Induced X-ray Emission (PIXE) technique. At present, there is not information available about elements contents in airborne particulate matter from this region. For this study, we carried out a sampling campaign during five months (November 14, 2006 to April 19, 2007). The samples were collected every second day during 24 h under an air flux of 20 l/min. The air sampler used was a Gent Sampler equipped with a Stacked Filter Unit (SFU) system which allows the aerosol collection in both size fractions simultaneously. A total of 144 aerosol samples were collected (72 correspond to the fine mass particle and 72 to the coarse mass particle). For PIXE analysis, the samples were irradiated by 2.5 MeV energy protons from the 2MV Van de Graff Tandetron Accelerator from the Laboratory of PIXE analysis at ININ, Mexico. A total of 14 elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br and Pb) were consistently detected in both particle size fractions with minimum detection limits in the range of 1-10 ng/m3. The quantitative results obtained from PIXE elemental analysis for mass of particles in both fractions have revealed important information that has been used in a first attempt to understand and to characterize the atmospheric pollution of this area. A general discussion about these results is presented in this paper. (author)

  13. Application of PIXE analysis to study urban atmospheric aerosols from downtown Havana City

    International Nuclear Information System (INIS)

    Perez Zayas, Grizel; Pinnera Hernandez, Ibrahin; Ramos Aruca, Maridelin; Guibert Gala, Rolando; Molina Esquivel, Enrique; Martinez Varona, Miriam; Fernandez Arocha, Ariadna; Aldape Ugalde, Francisca; Flores Maldonado, Javier

    2009-01-01

    The present work reports, the results of a first study of elemental composition in airborne particulate matter (in fine and coarse particle size fractions) collected at the Atmospheric Monitoring Station in the Municipality of Centro Habana, using the Particle-Induced X-ray Emission (PIXE) technique. At present, there is not information available about elements contents in airborne particulate matter from this region. For this study, we carried out a sampling campaign during five months (November 14, 2006 to April 19, 2007). The samples were collected every second day during 24 h under an air flux of 20 l/min. The air sampler used was a Gent Sampler equipped with a Stacked Filter Unit (SFU) system which allows the aerosol collection in both size fractions simultaneously. A total of 144 aerosol samples were collected (72 correspond to the fine mass particle and 72 to the coarse mass particle). For PIXE analysis, the samples were irradiated by 2.5 MeV energy protons from the 2MV Van de Graff Tandetron Accelerator from the Laboratory of PIXE analysis at ININ, Mexico. A total of 14 elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br and Pb) were consistently detected in both particle size fractions with minimum detection limits in the range of 1-10 ng/m3. The quantitative results obtained from PIXE elemental analysis for mass of particles in both fractions have revealed important information that has been used in a first attempt to understand and to characterize the atmospheric pollution of this area. A general discussion about these results is presented in this paper. (author)

  14. PIXE analysis of trace and other mineral elements in Romanian dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Iordan, Andreea; Harangus, Livia; Ciortea, C.; Moldovan, Maria

    2002-01-01

    Dental composites made of silicates and oxides particles embedded in an organic polymer, show a dynamic evolution but are rather expensive. Recently, the Romanian biomaterial 'Restacril' offered a low-cost alternative. Because the durability of the composite dental fillings depends both on the main chemical composition and on the impurities that may influence the inorganic particles' properties and thus modifying the bio material clinical behaviour, the elemental analysis of the material is necessary for improving its quality. Particle-induced X-ray emission (PIXE), a sensitive method for multielemental trace detection widely used in biomedical applications, allowed us to evidence 21 mineral elements with Z > 14 in some commercial dental composites. Here we evaluate the performances of PIXE for the control of dental composites by carrying out qualitative analysis of three Romanian biomaterials. PIXE measurements on thick composite samples with a flat surface were done with 3 MeV protons at the NIPNE-HH (Horia Hulubei National Institute for Physics and Nuclear Engineering) tandem accelerator, using a hyper-pure Ge detector, 30 mm thick Al absorber foil and integration of beam current. Up to 21 elements with Z > 19 were detected: K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Ga, Sr, Zr, Nb, Ru, Ag, Ba, Yb, Nd, Hf, Au, As and Pb. The orders of magnitude of relative concentrations were evaluated using X-ray yields obtained for another light element thick composite target. The Romanian composites have specific and diverse compositions, containing a great number of minor and trace elements, many of whom are impurities. Use of higher purity raw materials is suggested to reduce the latter and improve the materials' quality. Refinement of X-ray yields by better matching matrixes calculations and use of concentration standards are proposed for quantitative PIXE analysis of the dental composites. (authors)

  15. Study on atmosphere pollution by PIXE analysis combining with statistical method

    International Nuclear Information System (INIS)

    Zhu Guanghua

    1994-06-01

    Atmospheric aerosol samples were collected using an 8-stage cascade impactor or an automatic time sequence step sampler at Jomo Langma, Zhangye at the edge of Gobi Desert and Beijing. Element concentration were analyzed by PIXE (proton induced X-ray emission) technique. The data were analyzed by APCA (absolute principal component analysis) to determine the principal components. The sources and contribution to the aerosol in the above three regions were discussed. The result shows that the PIXE has high sensitivity, multi-element capability, high speed and non-destruction advantages. APCA analytical method can effectively determine the aerosol components in urban area, and it also can distinguish between local components and remote components in the area far from the pollution resources

  16. Thick-target Pixe analysis of chromium, copper and arsenic impregnated lumber

    International Nuclear Information System (INIS)

    Saarela, K-E.; Harju, L.; Lill, J-O.; Rajander, J.; Lindroos, A.; Heselius, S-J.

    1999-01-01

    Chromium, copper and arsenic (CCA) have for decades been used for wood preservation. Of these elements especially arsenic is very toxic. As CCA impregnated wood is still today used for many construction purposes, a monitoring of these metal ions is of great environmental importance. Thick-target PIXE is a powerful method for the determination of trace metals in wood. The TTPIXE method enabled study of variations of the elemental concentrations in lumber treated with CCA impregnation solution. Distribution patterns were obtained for both naturally occurring elements and elements introduced in the treatment process. During the impregnation process a desorption of e.g. alkali metal ions takes place from the wood. The sensitivity of the method is improved by dry ashing of the samples prior to PIXE analysis. The TTPIXE method was calibrated and validated using international certified reference materials (CRM) based on wood material

  17. PIXE analysis on the absorption of strontium by plants under hydroponic culture

    International Nuclear Information System (INIS)

    Oguri, Yoshiyuki; Kondo, Kotaro

    2016-01-01

    90 Sr is one of the most toxic radioactive nuclides emitted from nuclear disasters. By experiments using the compounds of stable isotopes of Sr, the behavior of this nuclide in plants can be simulated very well (R. S. Russell and H. M. Squire: J. Exp. Bot., Vol. 9, No. 2, pp. 262-276 (1958)). In this paper, we present an application of PIXE (Particle-Induced X-ray Emission) analysis (S. A. E. Johansson, et al.: Particle-Induced X-Ray Emission Spectrometry (PIXE), Wiley-Interscience, New York, ISBN-13: 978-0471589440 (1995)) in the study of Sr absorption by a herbal plant grown in a compact hydroponic setup. (J.P.N.)

  18. Possibilities and conditions of applying PIXE analysis with external proton beam

    International Nuclear Information System (INIS)

    Potocek, V.

    1989-01-01

    The technical and methodological prerequisites are summed up for the use of the PIXE method with an external proton beam. The method is suitable for the preliminary analysis of unknown samples prior to the choice of the best suited analytical method, for the nondestructive analysis of rare samples such as unique works of art, of small amounts of materials which are difficult to access, etc., as well as for calibration and comparing analyses. As for the operators the application of the PIXE method with external proton beam assumes the availability of accelerator operating time, minimization of the length of exposure of the targets, optimization of parameters of the exciting beam and automation of the whole process. Attention is also devoted to technical provisions and organization of laboratory work. The design is described of an analytical unit using the PIXE method with external proton beam, and it is stated that the Van de Graaff accelerator at the Institute of Nuclear Physics in Rez near Prague could be used for the purpose. (Z.M.). 6 refs

  19. Improved Dynamic Analysis method for quantitative PIXE and SXRF element imaging of complex materials

    International Nuclear Information System (INIS)

    Ryan, C.G.; Laird, J.S.; Fisher, L.A.; Kirkham, R.; Moorhead, G.F.

    2015-01-01

    The Dynamic Analysis (DA) method in the GeoPIXE software provides a rapid tool to project quantitative element images from PIXE and SXRF imaging event data both for off-line analysis and in real-time embedded in a data acquisition system. Initially, it assumes uniform sample composition, background shape and constant model X-ray relative intensities. A number of image correction methods can be applied in GeoPIXE to correct images to account for chemical concentration gradients, differential absorption effects, and to correct images for pileup effects. A new method, applied in a second pass, uses an end-member phase decomposition obtained from the first pass, and DA matrices determined for each end-member, to re-process the event data with each pixel treated as an admixture of end-member terms. This paper describes the new method and demonstrates through examples and Monte-Carlo simulations how it better tracks spatially complex composition and background shape while still benefitting from the speed of DA.

  20. Long term fine aerosol analysis by XRF and PIXE techniques in the city of Rijeka, Croatia

    International Nuclear Information System (INIS)

    Ivošević, Tatjana; Orlić, Ivica; Radović, Iva Bogdanović

    2015-01-01

    Highlights: • For the first time in Croatia, long term of fine aerosol pollution is reported. - Abstract: The results of a long term, multi elemental XRF and PIXE analysis of fine aerosol pollution in the city of Rijeka, Croatia, are reported for the first time. The samples were collected during a seven months period (6th Aug 2013–28th Feb 2014) on thin stretched Teflon filters and analyzed by energy dispersive X-ray fluorescence (EDXRF) at the Laboratory for Elemental Micro-Analysis (LEMA), University of Rijeka and by Particle Induced X-ray Emission (PIXE) using 1.6 MeV protons at the Laboratory for Ion Beam Interactions (LIBI), Ruđer Bošković Institute, Zagreb. The newly developed micro-XRF system at LEMA provided results for 19 elements in the range from Si to Pb. The PIXE at the LIBI provided information for the same elements as well for the light elements such as Na, Mg and Al. Black carbon was determined with the Laser Integrated Plate Method (LIPM). The results were statistically evaluated by means of the positive matrix factorization (PMF). The seven major pollution sources were identified together with their relative contributions, these are: secondary sulfates, road traffic, smoke, road dust, sea spray, ship emissions and soil dust.

  1. Long term fine aerosol analysis by XRF and PIXE techniques in the city of Rijeka, Croatia

    Energy Technology Data Exchange (ETDEWEB)

    Ivošević, Tatjana [Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka (Croatia); Orlić, Ivica [Department of Physics, University of Rijeka, Radmile Matejčić 2, HR-51000 Rijeka (Croatia); Radović, Iva Bogdanović [Laboratory for Ion Beam Interaction, Ruđer Bošković Institute, Bijenička 54, HR-10000 Zagreb (Croatia)

    2015-11-15

    Highlights: • For the first time in Croatia, long term of fine aerosol pollution is reported. - Abstract: The results of a long term, multi elemental XRF and PIXE analysis of fine aerosol pollution in the city of Rijeka, Croatia, are reported for the first time. The samples were collected during a seven months period (6th Aug 2013–28th Feb 2014) on thin stretched Teflon filters and analyzed by energy dispersive X-ray fluorescence (EDXRF) at the Laboratory for Elemental Micro-Analysis (LEMA), University of Rijeka and by Particle Induced X-ray Emission (PIXE) using 1.6 MeV protons at the Laboratory for Ion Beam Interactions (LIBI), Ruđer Bošković Institute, Zagreb. The newly developed micro-XRF system at LEMA provided results for 19 elements in the range from Si to Pb. The PIXE at the LIBI provided information for the same elements as well for the light elements such as Na, Mg and Al. Black carbon was determined with the Laser Integrated Plate Method (LIPM). The results were statistically evaluated by means of the positive matrix factorization (PMF). The seven major pollution sources were identified together with their relative contributions, these are: secondary sulfates, road traffic, smoke, road dust, sea spray, ship emissions and soil dust.

  2. Improved Dynamic Analysis method for quantitative PIXE and SXRF element imaging of complex materials

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, C.G., E-mail: chris.ryan@csiro.au; Laird, J.S.; Fisher, L.A.; Kirkham, R.; Moorhead, G.F.

    2015-11-15

    The Dynamic Analysis (DA) method in the GeoPIXE software provides a rapid tool to project quantitative element images from PIXE and SXRF imaging event data both for off-line analysis and in real-time embedded in a data acquisition system. Initially, it assumes uniform sample composition, background shape and constant model X-ray relative intensities. A number of image correction methods can be applied in GeoPIXE to correct images to account for chemical concentration gradients, differential absorption effects, and to correct images for pileup effects. A new method, applied in a second pass, uses an end-member phase decomposition obtained from the first pass, and DA matrices determined for each end-member, to re-process the event data with each pixel treated as an admixture of end-member terms. This paper describes the new method and demonstrates through examples and Monte-Carlo simulations how it better tracks spatially complex composition and background shape while still benefitting from the speed of DA.

  3. Mineral elements in dental composites by atomic and nuclear analytical methods. II. Improved analysis by PIXE

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Ciortea, C.; Fluerasu, D.; Enescu, S.E.; Preoteasa, Elena

    2000-01-01

    In the corrosive environment of the mouth, a diversity of interactions take place at the solid-solid and solid-liquid interfaces of a tooth's filling. Moreover, the mineral elements of the restorative material may induce a complex response of the organism. The approach of these problems requires sensitive surface elemental analysis of the composite and of the dental enamel and dentine. Particle-induced X-ray emission (PIXE) is such a method and has been applied in investigations of hard dental tissues; however, it was not used so far in the study of dental composites. We continue our study by evaluating the potential of PIXE for analysis of these materials. Three types of composites with two color shades each have been studied. The measurements were performed with 3 MeV protons, using a hyperpure Ge detector in a spectroscopic chain connected to a computer. The spectra were processed with the dedicated program Leone. PIXE without additional Al absorbent foil allowed the detection of Z > 14 elements in composites. In two glass- and ceramics-based materials we found: Ca, Zr, Ba, Yb and traces of Sr and In in Tetric Ceram (Vivadent); and Ca, Zr, Ba, Hf, possibly Mn, and traces of Ni, Ho, Ti, Fe, Cr in Valux Plus (3M Dental), after elimination of the escape peaks. In quartz-based Evicrol (Spofa), Si, Ca, Ti, Fe and traces of K, Cr, Ni, Cu, Zn were seen. Materials with different color shades showed variations of Ti, Cr, Fe, Ni and Cu in Evicrol, as contrasted to Tetric Ceram and Valux Plus whose spectra were color-invariant. By its sensitivity and low background, PIXE enables the detection of many trace elements in dental composites; it could serve also in new materials' development and forensic expertise. (authors)

  4. K, L, and M shell datasets for PIXE spectrum fitting and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, David D., E-mail: dcz@ansto.gov.au; Crawford, Jagoda; Siegele, Rainer

    2015-11-15

    Highlights: • Differences between several datasets commonly used by PIXE codes for spectrum fitting and concentration estimates have been highlighted. • A preferred option dataset was selected which includes ionisation cross sections, fluorescence yield, Coster–Kronig probabilities and X-ray line emission rates for K, L and M subshells. • For PIXE codes differences of several tens of percent can be seen for selected elements for L and M lines depending on the data sets selected. - Abstract: Routine PIXE analysis programs, like GUPIX, GEOPIXE and PIXAN generally perform at least two key functions firstly, the fitting of K, L and M characteristic lines X-ray lines to a background, including unfolding of overlapping lines and secondly, the use of a fitted primary Kα, Lα or Mα line area to determine the elemental concentration in a given matrix. To achieve these two results to better than 3–5% the data sets for fluorescence yields, emission rates, Coster–Kronig transitions and ionisation cross sections should be determined to better than 3%. There are many different theoretical and experimental K, L and M datasets for these parameters. How they are applied and used in analysis programs can vary the results obtained for both fitting and concentration determinations. Here we discuss several commonly used datasets for fluorescence yields, emission rates, Coster–Kronig transitions and ionisation cross sections for K, L and M subshells and suggests an optimum set to obtain consistent results for PIXE analyses across a range of elements with atomic numbers from 5 ⩽ Z ⩽ 100.

  5. PIXE analysis as a tool for dating of ice cores from the Greenland ice sheet

    International Nuclear Information System (INIS)

    Hansson, H.C.; Swietlicki, E.; Larsson, N.P.O.; Johnsen, S.J.

    1993-01-01

    Sections from the 2037 m long Dye 3 ice core drilled in 1979-1981 in the ice sheet of Southern Greenland were analysed with PIXE. The seven selected sections were from depths between 1778 and 1813 m, which corresponds to a time interval between about 8 500 and 10 000 years B.C. at the end of the last Ice Age. During this time period, fast climatic changes of several degrees centrigrade per century are known to have taken place. The exact time scales of these changes need yet to be verified by renewed measurements using nonconventional stratigraphic dating techniques such as PIXE. The problem is highly relevant for the prediction of climatic changes in our present age. A new sample preparation technique was developed which enables the determination of annual thicknesses of the parts of the ice core representing 10 000-40 000 years before present, where the thickness of the annual ice layers are believed to be less than 2.5 cm. More commonly used techniques of dating, such as measurements of oxygen and hydrogen isotopes δ 18 O and δD, nitrate, acidity or conductivity all have difficulties in resolving annual cycles in thicknesses of less than about 2 cm. The new technique involves sublimation of 18 cm long ice sections, after which the material contained in the ice is deposited on the thin backing. In this way, the material to be analysed is preconcentrated through the removal of the H 2 O, while still retaining the spatial distribution pattern of the various water soluble and insoluble components along the ice core. The resulting spatial resolution of the sublimation technique is estimated to be ±1 mm. A PIXE analysis was performed in contiguous millimeter steps across the sublimated ice sections. Estimations of annual ice layer thicknesses were based on the patterns of seasonal variation along the ice sections for several major and minor elements quantified with PIXE. (orig./TW)

  6. PIXE analysis of Thaumatococcus danielli in Osun state of Nigeria

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Osinkolu, G.A.; Pelemo, D.A.; Oladele, A.T.

    2013-01-01

    Full text: Thaumatococcus danielli (Marantaceae Benn.) Benth [Miraculous berry] is a multi-purpose perennial herb that is widely distributed in the tropical rainforest areas of West Africa. The leaves are simple, broad with slender stems connected underground to the perennial rhizomes. Farmers grow it in pockets within cocoa (Theobroma cacao) and kola (Cola nitida) plantations in South western Nigeria, Ghana and Cameroon. Propagation is mainly by rhizomes cuttings and occasionally by the seed. T. danielli plays very important roles in the rural economy generating income for the peasant farmers and traders. T. danielli is used mainly in three ways by the people. The leaves are used in food wrapping because of its very good flavour and its preservative ability; and roof thatching while the stem is locally used as straw in weaving mats and in making baskets, bags, hats, hand fans and other artistic works. Research has shown that the fruits of T.danielli contain low-calorie protein named 'Thaumatin' which is about 2000 times as sweet as sucrose. The stems also can be processed to produce fibre industrially in addition to the industrial potential of Thaumatin. Thaumatin have been implicated to be suitable sweetener for diabetes patients. However, despite the great economic values, potentials and benefits of T. danielli, there is hardly any data on its elemental compositions. This work therefore presents the elemental composition of T. danielli plant's parts (Ieaves, stems, fruits (mesocarps), seeds and roots (rhizomes)) from six different towns in Osun State of Nigeria using the Particle Induced X-ray Emission (PIXE) technique. The 2.0 MV collimated proton beam from the NEC 1.7 MV 5SDH Tandem accelerator of the Centre for Energy Research and Development(CERD), Obafemi Awolowo University, Ile-lfe, Nigeria was employed for the measurements. The results showed the detection of elements which include K, Ca, Fe, Mn, Sr, Zn, Pb, Br, and CI at various

  7. PIXE analysis of Thaumatococcus danielli in Osun state of Nigeria

    Energy Technology Data Exchange (ETDEWEB)

    Olabanji, S.O.; Osinkolu, G.A.; Pelemo, D.A., E-mail: skayode2002@yahoo.co.uk [Centre for Energy Research and Development (CERD), Obafemi Awolowo University (OAU), Ile-lfe (Nigeria); Oladele, A.T. [Department of Pharmacognosy, Facully of Pharmacy, Obafemi Awolowo University (OAU), Ile-lfe (Nigeria)

    2013-07-01

    Full text: Thaumatococcus danielli (Marantaceae Benn.) Benth [Miraculous berry] is a multi-purpose perennial herb that is widely distributed in the tropical rainforest areas of West Africa. The leaves are simple, broad with slender stems connected underground to the perennial rhizomes. Farmers grow it in pockets within cocoa (Theobroma cacao) and kola (Cola nitida) plantations in South western Nigeria, Ghana and Cameroon. Propagation is mainly by rhizomes cuttings and occasionally by the seed. T. danielli plays very important roles in the rural economy generating income for the peasant farmers and traders. T. danielli is used mainly in three ways by the people. The leaves are used in food wrapping because of its very good flavour and its preservative ability; and roof thatching while the stem is locally used as straw in weaving mats and in making baskets, bags, hats, hand fans and other artistic works. Research has shown that the fruits of T.danielli contain low-calorie protein named 'Thaumatin' which is about 2000 times as sweet as sucrose. The stems also can be processed to produce fibre industrially in addition to the industrial potential of Thaumatin. Thaumatin have been implicated to be suitable sweetener for diabetes patients. However, despite the great economic values, potentials and benefits of T. danielli, there is hardly any data on its elemental compositions. This work therefore presents the elemental composition of T. danielli plant's parts (Ieaves, stems, fruits (mesocarps), seeds and roots (rhizomes)) from six different towns in Osun State of Nigeria using the Particle Induced X-ray Emission (PIXE) technique. The 2.0 MV collimated proton beam from the NEC 1.7 MV 5SDH Tandem accelerator of the Centre for Energy Research and Development(CERD), Obafemi Awolowo University, Ile-lfe, Nigeria was employed for the measurements. The results showed the detection of elements which include K, Ca, Fe, Mn, Sr, Zn, Pb, Br, and CI at various

  8. Towards truly simultaneous PIXE and RBS analysis of layered objects in cultural heritage

    International Nuclear Information System (INIS)

    Pascual-Izarra, Carlos; Barradas, Nuno P.; Reis, Miguel A.; Jeynes, Chris; Menu, Michel; Lavedrine, Bertrand; Ezrati, Jean Jacques; Roehrs, Stefan

    2007-01-01

    For a long time, RBS and PIXE techniques have been used in the field of cultural heritage. Although the complementarity of both techniques has long been acknowledged, its full potential has not been yet developed due to the lack of general purpose software tools for analysing the data from both techniques in a coherent way. In this work we provide an example of how the recent addition of PIXE to the set of techniques supported by the DataFurnace code can significantly change this situation. We present a case in which a non homogeneous sample (an oxidized metal from a photographic plate - heliography - made by Niepce in 1827) is analysed using RBS and PIXE in a straightforward and powerful way that can only be performed with a code that treats both techniques simultaneously as a part of one single and coherent analysis. The optimization capabilities of DataFurnace, allowed us to obtain the composition profiles for these samples in a very simple way

  9. Grain-size effects on PIXE and INAA analysis of IAEA-336 lichen reference material

    Science.gov (United States)

    Marques, A. P.; Freitas, M. C.; Wolterbeek, H. Th.; Verburg, T. G.; De Goeij, J. J. M.

    2007-02-01

    IAEA-336 lichen certified reference material was used to compare outcomes from INAA and PIXE elemental analyses, in relationship with grain size. The IAEA material (grain size lichen reference material's particle size distribution follows a bimodal distribution, which is turning more and more monomodal after further fine sieving. Replicates of each fraction were analysed by INAA and PIXE. Results for Cl, K, Mn, Fe and Zn by both techniques were compared by application of z-values tested against the criterion ∣ z∣ limited amount of lichen material as "seen" in the PIXE analysis and the grain size distribution in the lichen material were no causes of measurable differences between the results of both techniques. However, fractionation into smaller grain sizes showed to be associated with lower element content, for Na, Cl, K, Mn and Sr even up to a factor of 2. The observed increases of the proportion of algae in the smaller grain-size fractions and the possible accumulation capacity for certain elements in the fungal part of the lichen may explain the observed phenomenon. The sieving process and consequently the discarding of part of the material have lead to a change of the properties of the original sample, namely algae/fungus percentage and elemental contents.

  10. Development of in-air micro-PIXE analysis and data sharing systems in JAERI Takasaki

    International Nuclear Information System (INIS)

    Sakai, Takuro; Kamiya, Tomihiro; Oikawa, Masakazu

    2000-01-01

    An external scanning ion microbeam system has been developed for in-air micro-PIXE analysis at JAERI Takasaki. The analysis system is widely used for various researches in recent years. The system consists of the external scanning ion microbeam system, a multi-parameter data acquisition system, a file transfer protocol (FTP) server and analysis software. The software of the system provides a graphical user interface for interaction between users and an experimental setup. The server is connected to the Internet and allows remote users to access the experimental data. (author)

  11. PIXE analysis on Maya blue in Prehispanic and colonial mural paintings

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez del Rio, M. [Departamento de Fisica, Universidad Autonoma Metropolitana, Iztapalapa, DF 09340 (Mexico); Martinetto, P. [Laboratoire de Cristallographie, CNRS, BP 166, F-30842 Grenoble (France); Solis, C. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Mexico, DF 04510 (Mexico)]. E-mail: corina@fisica.unam.mx; Reyes-Valerio, C. [Instituto Nacional de Antropologi' a e Historia, Mexico, DF (Mexico)

    2006-08-15

    Particle induced X-ray emission (PIXE) experiments have been carried out at the AGLAE facility (Paris) on several mural samples containing Maya blue from different Prehispanic archaeological sites (Cacaxtla, El Tajin, Tamuin, Santa Cecilia Acatitlan) and from several colonial convents in the Mexican plateau (Jiutepec, Totimehuacan, Tezontepec and Cuauhtinchan). The analysis of the concentration of several elements permitted to extract some information on the technique used for painting the mural, usually fresco. Principal component analysis permitted to classify the samples into groups. This grouping is discussed in relation to geographic and historic data.

  12. PIXE analysis on Maya blue in Prehispanic and colonial mural paintings

    Science.gov (United States)

    Sánchez del Río, M.; Martinetto, P.; Solís, C.; Reyes-Valerio, C.

    2006-08-01

    Particle induced X-ray emission (PIXE) experiments have been carried out at the AGLAE facility (Paris) on several mural samples containing Maya blue from different Prehispanic archaeological sites (Cacaxtla, El Tajín, Tamuin, Santa Cecilia Acatitlán) and from several colonial convents in the Mexican plateau (Jiutepec, Totimehuacán, Tezontepec and Cuauhtinchán). The analysis of the concentration of several elements permitted to extract some information on the technique used for painting the mural, usually fresco. Principal component analysis permitted to classify the samples into groups. This grouping is discussed in relation to geographic and historic data.

  13. PIXE analysis of trace and other mineral elements in phytopharmaceutical drugs

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Harangus, Livia; Iordan, Andreea; Gugiu, M.

    2002-01-01

    Despite of ongoing progress in the biochemistry of phytopharmaceutical drugs, their mineral micro- and trace elements have not been studied in detail. These elements may have therapeutic or toxic activity which should be assessed by sensitive investigations. The latter can be done by multielemental analysis with nuclear and atomic methods. We previously found 28 elements in some Romanian plant drugs by nuclear activation analysis. The availability of this method is, however, limited by the access to a nuclear reactor. Particle-induced X-ray emission (PIXE) is an alternative method with high performances in biomedicine and requiring no sample preparation for drugs' studies. We applied PIXE in the qualitative analysis of three plant drugs - Liv52, Mentat, and Geriforte - used as invigorators, protectors and prophylactics in oxidative stress diseases. Measurements with 3 MeV protons at the 8.5 MV NIPNE-HH (Horia Hulubei National Institute for Physics and Nuclear Engineering) tandem accelerator, using a hyper-pure Ge detector and no additional absorber foil, evidenced unusually complex elemental compositions of drugs. Up to 31 elements with Z > 15 were found: P, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Zr, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Hg, and As and/or Pb, from major to trace levels. The three drugs' qualitative composition were found to be rather similar. Relative concentrations were well evaluated with X-ray yields calculated for another kind of light element thick target. Drug's toxic elements - As and/or Pb, Hg, and possibly Ga - were all at trace levels, but their accumulation might be harmful. Some essential elements like K, Ca, Cr, Fe, Cu, Zn, Br, Rb, Sr can be biologically useful. X-ray yields improvement and other ways for PIXE quantitative analysis of the phytotherapeutic drugs are outlined. (authors)

  14. Neutron activation and PIXE analysis of oyster tissues cultivated at different ocean depths for trace elements

    International Nuclear Information System (INIS)

    Fukushima, M.; Nakano, Y.; Chatt, A.

    2005-01-01

    Difference in trace element concentrations in oyster tissues cultivated in Japan on hanging ropes at different sea depths were investigated using INAA and PIXE. Three groups of oyster were collected from a single rope at 1 m, 6 m, and 11 m depths. From each group, five oysters were chosen and removed from the shell after washing in tap water. Two groups of organ, namely hepatopancreas and muscle, and gill and mantle were separated from soft tissues, freeze-dried, and pulverized. One portion of the powdered samples was irradiated for a short time at the Dalhousie University SLOWPOKE-2 reactor in Canada for Ag and Se analysis. Another portion was irradiated for one hour in Kyoto University Reactor in Osaka, Japan for Fe, Rb, Sc, and Zn analysis. The third portion was digested in a microwave oven after the addition of an indium solution (as an internal standard) and concentrated nitric acid for analysis by PIXE. More than twenty elements were determined by PIXE. The organs in oysters have different roles. For example, hepatopancreas and muscle are thought to accumulate elements after ingestion of plankton from sea water while gill and mantle are always in contact with sea water. As a result, there were differences in levels of some elements between the two groups of organ. In addition, levels of most elements were found to be depth dependent. The variations in Fe and Zn concentrations of the two organ groups at 3 different depths are shown in Table 1. Details of the method and results will be presented.

  15. The combined application of PIXE analysis and thermoluminescence (TL) dating for elucidating the origin of iron manufacturing in Japan

    International Nuclear Information System (INIS)

    Hagihara, N.; Miono, S.; Chengzhi, Z.; Nakayama, Y.; Hanamoto, K.; Manabe, S.

    1999-01-01

    For elucidating the origin of iron manufacturing in Japan, the usefulness of PIXE analysis was reconfirmed and a new technique of thermoluminescence (TL) dating was applied. Through reproducing experiments of iron manufacturing and forging, PIXE analysis was tested for classifying the iron slag produced from these two different process. The TL dating method was improved for experiments with the iron manufacturing furnace, burnt at high temperature (about 1300 K) and irradiated with relatively low dose. Utilizing PIXE analysis, the iron manufacturing furnace can be distinguished from the older forging furnace used for the imported iron plate. Adopting TL dating, the oldest iron manufacturing furnace can be found out. Some ancient samples in Japan were used as a test of this combined application, and the results were positive, thus proving the suitability of the method

  16. Evaluation of the applicability of the MOUDI impactor for aerosol collections with subsequent multielement analysis by PIXE

    International Nuclear Information System (INIS)

    Maenhaut, W.; Ducastel, G.; Hillamo, R.E.; Pakkanen, T.A.

    1993-01-01

    The micro-orifice uniform deposit impactor (MOUDI) is an 8-stage impactor with cut-sizes down to 0.056 μm and which allegedly provides uniform aerosol deposits for the various stages. In the present study it was examined how uniform the aerosol deposits really are for each impaction plate, and whether the uniformity is sufficient for a straightforward PIXE analysis. This was done by collecting several samples of ambient aerosol with the MOUDI and by determining the deposition pattern of various elements on the foils through a linear PIXE scan across each impaction foil. It was found that the deposits are far from uniform at the millimeter level for the stage numbers up to 6. Despite this, concentration data can easily be obtained by PIXE from such samples, provided that the analyzed area is carefully selected and appropriate correction factors for the nonuniformity are employed. Some size distribution data are presented. A comparison is also made of the size distribution data and detection limits that result from employing the MOUDI in combination with PIXE with those obtainable by PIXE analysis of some other types of cascade impactors. (orig.)

  17. Grain-size effects on PIXE and INAA analysis of IAEA-336 lichen reference material

    International Nuclear Information System (INIS)

    Marques, A.P.; Freitas, M.C.; Wolterbeek, H.Th.; Verburg, T.G.; Goeij, J.J.M. de

    2007-01-01

    IAEA-336 lichen certified reference material was used to compare outcomes from INAA and PIXE elemental analyses, in relationship with grain size. The IAEA material (grain size <125 μm) was ground and sieved through nylon nets with 64 μm, 41 μm and 20 μm pores. Particle sizes were determined by Laser Light Scattering technique: the data indicate that, after sieving, the IAEA-336 lichen reference material's particle size distribution follows a bimodal distribution, which is turning more and more monomodal after further fine sieving. Replicates of each fraction were analysed by INAA and PIXE. Results for Cl, K, Mn, Fe and Zn by both techniques were compared by application of z-values tested against the criterion vertical bar z vertical bar < 3 for approval of results at the 99.7% confidence level. Under the conditions of this study, the limited amount of lichen material as 'seen' in the PIXE analysis and the grain size distribution in the lichen material were no causes of measurable differences between the results of both techniques. However, fractionation into smaller grain sizes showed to be associated with lower element content, for Na, Cl, K, Mn and Sr even up to a factor of 2. The observed increases of the proportion of algae in the smaller grain-size fractions and the possible accumulation capacity for certain elements in the fungal part of the lichen may explain the observed phenomenon. The sieving process and consequently the discarding of part of the material have lead to a change of the properties of the original sample, namely algae/fungus percentage and elemental contents

  18. Trace-Element Analysis by Use of PIXE Technique on Agricultural Products

    Science.gov (United States)

    Takagi, A.; Yokoyama, R.; Makisaka, K.; Kisamori, K.; Kuwada, Y.; Nishimura, D.; Matsumiya, R.; Fujita, Y.; Mihara, M.; Matsuta, K.; Fukuda, M.

    2009-10-01

    In order to examine whether a trace-element analysis by PIXE (Particle Induced X-ray Emission) gives a clue to identify production area of agricultural products, we carried out a study on soy beans as an example. In the present study, a proton beam at the energy of 2.3MeV was provided by Van de Graaff accelerator at Osaka University. We used a Ge detector with Be window to measure X-ray spectra. We prepared sample soy beans from China, Thailand, Taiwan, and 7 different areas in Japan. As a result of PIXE analysis, 5 elements, potassium, iron, zinc, arsenic and rubidium, have been identified. There are clear differences in relative amount of trace-elements between samples from different international regions. Chinese beans contain much more Rb than the others, while there are significant differences in Fe and Zn between beans of Thailand and Taiwan. There are relatively smaller differences among Japanese beans. This result shows that trace-elements bring us some practical information of the region where the product grown.

  19. Potential of PIXE for the elemental analysis of calcium hydroxide used in dentistry

    International Nuclear Information System (INIS)

    Suciu, Ioana; Ionescu, Ecaterina; Bodnar, Dan; Preoteasa, Eugen A.; Gurban, Dan

    2006-01-01

    Calcium hydroxide is used in dentistry and generally shows a clinically acceptable biocompatibility. However various commercial assortments show differences in their clinical performances, suggesting that certain aspects of their action are not completely understood and pointing to the necessity of new investigation methods. We report a preliminary study on two types of calcium hydroxide products carried out by thick target PIXE with 3.0 MeV protons, aiming to assess the potential of this method for the analysis of such biomaterials used in endodontic dentistry. (Semi)quantitative analysis was performed by use of reference materials, and relative concentrations of elements with respect to Ca were determined with an accuracy of about 30%; tentative absolute concentrations were also estimated by using Ca as a reference element. In both formulations, a number of trace elements (Mn, Fe, Zn and Sr, and possibly Cu and Pb - probably impurities from the raw materials) were evidenced. These trace elements together with the Ba/Ca ratio are reliable fingerprints for the identification of the materials, and evidenced a different origin for the Ca(OH) 2 used in the two specimens. Possible applications of PIXE in dental research may bring relevant compositional insight, and further studies of such materials are suggested. (authors)

  20. Application of PIXE analysis to investigation of plants cultivated with contaminated soil of Fukushima

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, K., E-mail: keizo.ishii@qse.tohoku.ac.jp [Research Center for Remediation Engineering of Living Environments Contaminated with Radioisotopes, Department of Quantum Science and Energy Engineering, Tohoku University, 6-6 Aza-Aoba, Aramaki, Aoba-ku, Sendai 980-8579 (Japan); Terakawa, A.; Matsuyama, S.; Ishizaki, A.; Arai, H.; Osada, N.; Sugai, H.; Takahashi, H. [Research Center for Remediation Engineering of Living Environments Contaminated with Radioisotopes, Department of Quantum Science and Energy Engineering, Tohoku University, 6-6 Aza-Aoba, Aramaki, Aoba-ku, Sendai 980-8579 (Japan); Sera, K. [Cyclotron Research Center, Iwate Medical University, 348-58 Tomegamori, Takizawa, Iwate 020-0173 (Japan); Sasaki, H.; Sasaki, K.; Sawamura, T. [Sasaki Taro memorial PIXE Center, Asano-cho 5, Hakodate 040-0076 (Japan)

    2014-08-01

    We present a method to research low radioactive cesium contaminated plants by the use of PIXE analysis. Highly contaminated regions still remain in the Fukushima prefecture. We collected wild plants growing in this area, that is, Butterbur, Welsh onion, Alpine leek and White clover and measured their specific activities of {sup 137}Cs and {sup 40}K. We also measured {sup 137}Cs and {sup 40}K specific activities of soil under these plants. Soil-to-plant transfer factors of {sup 137}Cs were ∼0.02 for 4 wild plants and those of {sup 40}K were ∼0.5 except for White clover. Using PIXE analysis, we measured the concentration of mineral elements in these plants. Among mineral elements, we noted the concentrations of additional alkali metal elements such as Na, K and Rb. The experimental results showed that the concentration of Rb was proportional to the specific activities of {sup 137}Cs except for Welsh onion and other elements had no strong correlation with {sup 137}Cs. These results indicate that there may be correlations between the adsorption of Cs and Rb.

  1. Improved PIXE analysis of micro- and trace elements in dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Ciortea, C.; Fluerasu, D.; Enescu, S. E.; Preoteasa, E.

    2001-01-01

    Due to the interactions occurring at the solid-solid and solid-liquid interfaces of a tooth's filling, the mineral elements of the restorative composite may induce a complex response of the organism. To study such problems, sensitive surface trace element analysis is required. Particle-induced X-ray emission (PIXE) has a detection limit one order of magnitude lower than XRF and has been used for hard dental tissues, but not yet for dental composites. We evaluated the potential of PIXE in a study of ten types of composites used in restorative dentistry, some of them with two color shades each. The samples were prepared as described for XRF. The measurements were performed with 3 MeV protons from a van de Graaff tandem linear accelerator, using a hyper pure Ge detector and collecting the spectra for 1.5-4 hours. The spectra were processed with the program Leone. The proton route in the sample calculated with the Trim program (∼ 50-100 μm) exceeded the size of mineral particles (0.02-30 μm), thus granularity did not affect the analysis. The PIXE analysis detected Z ≥ 19 elements in all composites, and Z≥14 elements in only one low Z material. PIXE detected generally the same dominant elements, but many more trace elements than XRF. Thus both Charisma (Kulzer) and Pekafill (Bayer) contained Ba as the major element, but trace elements were Ni, Zn, In, in the first, and Fe, Cu, Zn, Sr, Ag in the second. In other glass- and ceramics-based materials we found: Ca, Zr, Ba, Yb and traces of Sr, In, and possibly Ti in Tetric Ceram and in Ariston (both from Vivadent); Ca, Zr, Ba, Hf, possibly Mn, and traces of Ni, Ho, Ti, Fe, Cr in Valux Plus (3M Dental); Sr, Ba (major), K, Fe, Mn (minor), and traces of Ni, Zn, In, in F2000 Compomer (3M Dental); Ba (major) and traces of Fe, Ni, Sr in Surefil (Dentsply). In quartz-based materials we detected: Si, Ca, Ti, Fe and traces of K, Cl, Cr, Ni, Cu, Zn in Evicrol (Spofa); low and trace levels of Ca, Ti, Cr, Mn, Fe, Cu in

  2. External PIXE analysis of an Iranian 15th century poetry book

    Energy Technology Data Exchange (ETDEWEB)

    Kakuee, Omidreza, E-mail: okakuee@aeoi.org.ir [Nuclear Science Research School, NSTRI, P.O. Box 14395-836, Tehran (Iran, Islamic Republic of); Fathollahi, Vahid; Oliaiy, Parvin; Lamehi-Rachti, Mohammad [Nuclear Science Research School, NSTRI, P.O. Box 14395-836, Tehran (Iran, Islamic Republic of); Taheri, Raziyeh; Jafarian, Hosseinali A. [The Library, Museum and Documentation Center of the Islamic Republic of Iran Parliament, Tehran (Iran, Islamic Republic of)

    2012-02-15

    The paints of illumination, ink and paper of an Iranian poetry manuscript originally belonging to 15th century but partly restored about 300 years ago are characterized by external PIXE. The technique was employed to determine the elemental composition of different inks and paints applied in the text and illumination as well as the paper of both the original masterpiece and the restored parts in order to evaluate the quality of restoration processes. The X-ray spectra were collected by a Si(Li) X-ray detector placed at a scattering angle of 135 Degree-Sign while the beam charge was indirectly measured through the Ar K{sub {alpha}} X-ray yield originated from the irradiation of in-air Argon. By analysis of the collected PIXE spectra, concentration of different elements present in closely matched colored areas in the original and restored illuminations were compared. In the same way, the origin of colored pigments and black ink in the original and restored illuminations and texts are inferred.

  3. Analysis of some ancient glass samples unearthed in Sichuan area by PIXE

    International Nuclear Information System (INIS)

    Li Fei; Li Qinghui; Gan Fuxi

    2007-01-01

    Proton induced X-ray emission (PIXE) technique is an effective method for the chemical composition analysis of ancient glass samples without destruction. Chemical composition of the ancient glass samples dated from the Warring States Period (770-476 B.C.) to the Six Dynasties Period (220-589 A.D.), which were unearthed in Sichuan area, was quantitatively determined by the PIXE technique. The results show that the glass Bi (disc) and the glass eye beads of the Warring States Period all belong to the PbO-BaO-SiO 2 system. According to the composition and shape, we infer that these glass Bi and eye beads were made in China. Whereas, the chemical compositions of the glass ear pendants and beads of the Six Dynasties Period are varied, including K 2 O-CaO-SiO 2 , K 2 O-SiO 2 and other glass systems, Based on the obtained results and those from literatures, some questions related to the technical propagation of the ancient Chinese glass are discussed. (authors)

  4. PIGE-PIXE analysis of medicinal plants and vegetables of pharmacological importance

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Makanju, O.V.

    1995-08-01

    PIGE and PIXE techniques were employed to the study of elemental constituents of some traditional medicinal plants generally used in curing many diseases and ailments in South-Western Nigeria. Analysis were also carried out on commonly edible vegetables of medicinal and pharmacological importance. PIGE measurements were carried out using 3.5 MeV collimated protons from the 7 MV CN Van-de-Graaff accelerator of INFN, LNL, Legnaro (Padova), Italy, while the PIXE measurements were carried out using 1.8 MeV from the 2.5 MV AN 2000 Van-de-Graaff accelerator of the same laboratory. The results show that many of the medicinal plants contain elements of cardinal importance in man's metabolism. The results from the vegetables also show that presence of vital elements that are needed for growth and developments. In addition, some of the toxic elements which include arsenic, cadmium, mercury, etc. were not detected. However, some of the recipes contain trace amounts of lead at very low concentrations. This calls for proper control of dose rates in some samples to prevent the attendant negative cumulative effects. (author). 17 refs, 1 fig., 5 tabs

  5. Assessment of metal sorption mechanisms by aquatic macrophytes using PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Módenes, A.N., E-mail: anmodenes@yahoo.com.br [Department of Chemical Engineering-Postgraduate Program, West Parana State University, Campus of Toledo, rua da Faculdade 645, Jd. La Salle, 85903-000 Toledo, PR (Brazil); Espinoza-Quiñones, F.R.; Santos, G.H.F.; Borba, C.E. [Department of Chemical Engineering-Postgraduate Program, West Parana State University, Campus of Toledo, rua da Faculdade 645, Jd. La Salle, 85903-000 Toledo, PR (Brazil); Rizzutto, M.A. [Physics Institute, University of São Paulo, Rua do Matão s/n, Travessa R 187, 05508-900 São Paulo, SP (Brazil)

    2013-10-15

    Highlights: • Divalent metal ion removals by Egeria densa biosorbent. • Multielements concentrations in biosorbent samples by PIXE analysis. • Elements mass balance in liquid and solid phase before and after metal removals. • Assessment of the mechanisms involved in Cd{sup 2+} and Zn{sup 2+} removal by biosorbent. • Confirmation of the signature of ion exchange process in metal removal. -- Abstract: In this work, a study of the metal sorption mechanism by dead biomass has been performed. All batch metal biosorption experiments were performed using the aquatic macrophyte Egeria densa as biosorbent. Divalent cadmium and zinc solutions were used to assess the sorption mechanisms involved. Using a suitable equilibrium time of 2 h and a mixture of 300 mg biosorbent and 50 mL metal solution at pH 5, monocomponent sorption experiments were performed. In order to determine the residual amounts of metals in the aqueous solutions and the concentrations of removed metals in the dry biomass, Particle Induced X-ray Emission (PIXE) measurements in thin and thick target samples were carried out. Based on the strong experimental evidence from the mass balance among the major elements participating in the sorption processes, an ion exchange process was identified as the mechanism responsible for metal removal by the dry biomass.

  6. Analysis of ancient Indian silver punch-marked coins by external PIXE

    International Nuclear Information System (INIS)

    Rautray, Tapash R.; Nayak, Suman S.; Tripathy, Bipin B.; Das, Saubhagyalaxmi; Das, Manas R.; Das, Satya R.; Chattopadhyay, Pranab K.

    2011-01-01

    Seven silver punch-marked coins were analysed using external particle induced X-ray emission technique. The main group of elements like Ag, Cu, Au, Pb and Fe were estimated along with a number of trace/minor elements such as K, Ca, Ti, V, Cr, Mn, Co, Ni and Rb in the analysed silver coins. Gold was found in all the coins and varied between 0.7% and 6.2% indicating the better economic condition of that civilisation. - Highlights: → The silver punch-marked coins, in the current study, were in use in India between 6th century BC to 6th century AD and have been analysed by in-air PIXE. → These sets of coins have immense archaeological importance because of their very rare availability. → These coins are distinguished from other coins because of the presence of gold as major element. → While the British period coins were fabricated using modern technologies, the punch-marked coins were shaped manually with developed metal technology. → The analysis of punch-marked coins using external PIXE beam has been done for the first time, which is unique of its kind.

  7. External PIXE analysis of an Iranian 15th century poetry book

    International Nuclear Information System (INIS)

    Kakuee, Omidreza; Fathollahi, Vahid; Oliaiy, Parvin; Lamehi-Rachti, Mohammad; Taheri, Raziyeh; Jafarian, Hosseinali A.

    2012-01-01

    The paints of illumination, ink and paper of an Iranian poetry manuscript originally belonging to 15th century but partly restored about 300 years ago are characterized by external PIXE. The technique was employed to determine the elemental composition of different inks and paints applied in the text and illumination as well as the paper of both the original masterpiece and the restored parts in order to evaluate the quality of restoration processes. The X-ray spectra were collected by a Si(Li) X-ray detector placed at a scattering angle of 135° while the beam charge was indirectly measured through the Ar K α X-ray yield originated from the irradiation of in-air Argon. By analysis of the collected PIXE spectra, concentration of different elements present in closely matched colored areas in the original and restored illuminations were compared. In the same way, the origin of colored pigments and black ink in the original and restored illuminations and texts are inferred.

  8. Inorganic Profiling of Amoxicillin Drugs in Ghana Using Proton Induced X-Ray Emission (Pixe) Analysis

    International Nuclear Information System (INIS)

    Abdul-Wahab, Zurika

    2017-07-01

    The increase of drug counterfeits and its unconscious use has become a major cause for concern to health care practitioners and relevant stakeholders. The occurrence of counterfeit or fake drugs is perceived to be a problem encountered in both developing and underdeveloped nations where Ghana is not an exemption. The lethal implications of counterfeit/fake medications are well understood to be a major challenge to the soundness of public health systems around the world, as well as a direct threat to our individual health and well-being. Sub-standard and counterfeit/fake drugs are a widespread problem in Ghana and the need to address it is eminent. The volume of drugs that require control, from the statutory organisations like Food and Drugs Authority of Ghana (FDA) and Ghana Standard Authority (GSA) is enormous, and hence the need to explore other faster analytical techniques to help control cannot be over emphasised. According to the World Health Organization (WHO), Antibiotics are the most counterfeited drugs and Amoxicillin (C 16 H 19 N 3 O 5 S) happened to be ranked first on the list. The most used and prescribed method for drug quality control analysis is the High-Performance Liquid Chromatography (HPLC) technique which accesses the quality of drugs from its Active Principal Ingredient (API) perspective. The main focus of this study is to harness additional analytical procedure to enhance the routine monitoring of the quality of some Amoxicillin drugs in Ghana from the inorganic constituent point of view. HPLC and the physical parameter tests were carried out on the samples analysed to help validate the interpretation of the inorganic element results from the PIXE technique. Two different local brands of amoxicillin and two imported amoxicillin brands were chosen for this study. A total of 30 samples were analysed for this study including one (1) standard reference material (amoxicillin) acquired from a licenced pharmaceutical company in Ghana. Particle

  9. Mechanical behavior analysis on electrostatically actuated rectangular microplates

    Science.gov (United States)

    Li, Zhikang; Zhao, Libo; Jiang, Zhuangde; Ye, Zhiying; Dai, Lu; Zhao, Yulong

    2015-03-01

    Microplates are widely used in various MEMS devices based on electrostatic actuation such as MEMS switches, micro pumps and capacitive micromachined ultrasonic transducers (CMUTs). Accurate predictions for the mechanical behavior of the microplate under electrostatic force are important not only for the design and optimization of these electrostatic devices but also for their operation. This paper presents a novel reduced-order model for electrostatically actuated rectangular and square microplates with a new method to treat the nonlinear electrostatic force. The model was developed using Galerkin method which turned the partial-differential equation governing the microplates into an ordinary equation system. Using this model and cosine-like deflection functions, explicit expressions were established for the deflection and pull-in voltage of the rectangular and square microplates. The theoretical results were well validated with the finite element method simulations and experimental data of literature. The expressions for the deflection analysis are able to predict the deflection up to the pull-in position with an error less than 5.0%. The expressions for the pull-in voltage analysis can determine the pull-in voltages with errors less than 1.0%. Additionally, the method to calculate the capacitance variation of the electrostatically actuated microplates was proposed. These theoretical analyses are helpful for design and optimization of electrostatically actuated microdevices.

  10. Mechanical behavior analysis on electrostatically actuated rectangular microplates

    International Nuclear Information System (INIS)

    Li, Zhikang; Zhao, Libo; Jiang, Zhuangde; Ye, Zhiying; Zhao, Yulong; Dai, Lu

    2015-01-01

    Microplates are widely used in various MEMS devices based on electrostatic actuation such as MEMS switches, micro pumps and capacitive micromachined ultrasonic transducers (CMUTs). Accurate predictions for the mechanical behavior of the microplate under electrostatic force are important not only for the design and optimization of these electrostatic devices but also for their operation. This paper presents a novel reduced-order model for electrostatically actuated rectangular and square microplates with a new method to treat the nonlinear electrostatic force. The model was developed using Galerkin method which turned the partial-differential equation governing the microplates into an ordinary equation system. Using this model and cosine-like deflection functions, explicit expressions were established for the deflection and pull-in voltage of the rectangular and square microplates. The theoretical results were well validated with the finite element method simulations and experimental data of literature. The expressions for the deflection analysis are able to predict the deflection up to the pull-in position with an error less than 5.0%. The expressions for the pull-in voltage analysis can determine the pull-in voltages with errors less than 1.0%. Additionally, the method to calculate the capacitance variation of the electrostatically actuated microplates was proposed. These theoretical analyses are helpful for design and optimization of electrostatically actuated microdevices. (paper)

  11. PIXE analysis of hair samples from artisanal mining communities in the Acupan region, Benguet, Philippines

    International Nuclear Information System (INIS)

    Clemente, Eligia; Sera, K.; Futatsugawa, S.; Murao, S.

    2004-01-01

    The mountainous regions of Benguet Province in the Philippines is home to some 10,000 small-scale miners who make out a living by extracting gold. In these communities, the method of extraction still involves the use of mercury, via amalgamation. In the separation of gold from mercury the method involves the release of mercury vapor into the atmosphere. This is therefore expected to affect the people living in the nearby areas. This study involves the accumulation of baseline data on the extent of mercury contamination in humans through the analysis of their hair. In 1989, Hursh et al. [Arch. Environ. Health 44 (2) (1989) 120] studied human volunteers and found that uptake of mercury vapor through the skin is only about 1% of the uptake through inhalation [World Health Organization, IPCS, EHC118, Inorganic Mercury, Geneva, 1991, p. 42]. In this light, any residual mercury which might have deposited in human hair is speculated to give an indication of how much mercury vapor the subject could have actually inhaled. A high concentration of mercury in the sample can therefore be indicative of the high rate of intake of the mercury vapor through inhalation. A sampling of the community consisted of both male (83%) and female (17%) subjects who ranged in age from 8 to 66 years old. Hair analysis was done using particle induced X-ray emission at the Iwate Medical University through Dr. Sera. With Zn set as a standard element, the rest of the elements were determined using the standard-free method. In order to obtain the conversion coefficient for hair samples, many hair samples were analyzed by this method and the internal standard method which involves the preparation of the hair samples by chemical ashing. The results obtained were comparable. The PIXE results for these samples showed the analysis of 26 elements but for our purposes, however, only the mercury analysis will be considered. Results of the analysis showed the hair samples to contain 0-27 ppm, with only seven

  12. Correlation analysis of trace elemental data obtained from blood sera of ovarian cancer patients using PIXE

    International Nuclear Information System (INIS)

    Naidu, B.G.; Sarita, P.; Naga Raju, G.J.

    2017-01-01

    Proton induced X-ray emission (PIXE) technique is used for analysis of trace elements present in the blood sera of ovarian cancer patients and healthy controls. This work is also intended to establish the role played by trace elements in carcinogenic process. It is observed that the concentrations of elements Ti, V, Cr, Mn, Fe, Ni, Rb and Sr are lower and the concentration of Cu is higher in the cancer patients when compared to controls. However, no change in concentration is found in the elements Co, Zn, As, Se and Br. Correlation analysis of the data using SPSS 16.0 has revealed a strong positive correlation between Ti-V, Ni-Co, Cu-Fe, As-Ti, Br-Ti, Br-V and Sr-Fe while strong negative correlations are observed for Cu-Ti, As-Cu and Br-Cu. Changes in trace elemental content are probably associated with ovarian carcinogenesis. (author)

  13. Scanning-PIXE analysis of gold lace embroideries in a relic of St. Francis

    Energy Technology Data Exchange (ETDEWEB)

    Migliori, A. [Dipartimento di Fisica dell' Universita and Istituto Nazionale di Fisica Nucleare, Firenze, Via G. Sansone 1, 50019 Sesto Fiorentino (Firenze) (Italy)], E-mail: migliori@fi.infn.it; Grassi, N.; Mando, P.A. [Dipartimento di Fisica dell' Universita and Istituto Nazionale di Fisica Nucleare, Firenze, Via G. Sansone 1, 50019 Sesto Fiorentino (Firenze) (Italy)

    2008-05-15

    In this work, we describe the compositional analysis performed by scanning-mode PIXE on the metal threads of a XIII century embroidery. The precious work analysed is the pillow-case used to cover the pillow, on which - according to tradition - St. Francis of Assisi was resting his head when he died. Measurements were performed in order to characterise the embroideries of the two sides and the passementerie in the lateral hems. Several areas, each of the order of two square millimetres, were scanned with a 3 MeV proton external beam of 20 {mu}m size on target, using the external micro-beam facility of our laboratory, with list-mode acquisition. Analysis of elemental maps and spectra from selected homogeneous sub-areas allowed us to extract the quantitative composition of the gilded tape and estimates of its thickness.

  14. Scanning-PIXE analysis of gold lace embroideries in a relic of St. Francis

    International Nuclear Information System (INIS)

    Migliori, A.; Grassi, N.; Mando, P.A.

    2008-01-01

    In this work, we describe the compositional analysis performed by scanning-mode PIXE on the metal threads of a XIII century embroidery. The precious work analysed is the pillow-case used to cover the pillow, on which - according to tradition - St. Francis of Assisi was resting his head when he died. Measurements were performed in order to characterise the embroideries of the two sides and the passementerie in the lateral hems. Several areas, each of the order of two square millimetres, were scanned with a 3 MeV proton external beam of 20 μm size on target, using the external micro-beam facility of our laboratory, with list-mode acquisition. Analysis of elemental maps and spectra from selected homogeneous sub-areas allowed us to extract the quantitative composition of the gilded tape and estimates of its thickness

  15. Scanning-PIXE analysis of gold lace embroideries in a relic of St. Francis

    Science.gov (United States)

    Migliori, A.; Grassi, N.; Mandò, P. A.

    2008-05-01

    In this work, we describe the compositional analysis performed by scanning-mode PIXE on the metal threads of a XIII century embroidery. The precious work analysed is the pillow-case used to cover the pillow, on which - according to tradition - St. Francis of Assisi was resting his head when he died. Measurements were performed in order to characterise the embroideries of the two sides and the passementerie in the lateral hems. Several areas, each of the order of two square millimetres, were scanned with a 3 MeV proton external beam of 20 μm size on target, using the external micro-beam facility of our laboratory, with list-mode acquisition. Analysis of elemental maps and spectra from selected homogeneous sub-areas allowed us to extract the quantitative composition of the gilded tape and estimates of its thickness.

  16. Application of PIXE and NAA methods to the analysis of lichens from Antarctica

    International Nuclear Information System (INIS)

    Badica, T.; Popescu, I.V.; Cojocaru, V.; Olariu, A.; Stefanescu, I.; Petre, M.; Pantelica, A.; Salajan, M.; Balabanski, D.; Gourev, V.; Chipev, N.

    1999-01-01

    Proton Induced X-Ray Emission (PIXE) and Neutron Activation Analysis (NAA) have emerged as powerful analytical techniques for the detection of trace elements in environmental samples, especially in the antarctic environmental, because of its multielemental character and high sensitivity. This methods of analysis have been used to find the concentration of trace elements in the lichens collected from Antarctica zone. Trace contents of elements like As, Au, Ba, Br, Ca, Ce, Cl, Co, Cr, Cs, Cu, Eu, Fe, Hf, Hg, K, La, Mn, Na, Ni, Rb, S, Sb, Se, Sm, Sr, Ti, Tb, Th, U, Zn and Yb have been determined. Preliminary data suggest that nuclear methods may be useful in elucidating element absorption and transport mechanisms in lichens as a sensitive indicator of the species growing in the environmental polluted sites. (authors)

  17. Presumed cause of mass deaths of rooks (Corvus Frugilegus Pastinator) using PIXE analysis

    International Nuclear Information System (INIS)

    Saitoh, Katsumi; Kobayashi, Takashi; Sera, Koichiro; Yasuda, Masaaki; Kakino, Jun

    2007-01-01

    Eighty-nine wild birds were found dead in Ogata Village in northern Japan in March 2006. Eighty-eight of the birds were rooks (Corvus Frugilegus Pastinator), which are migratory birds. Since the use of rodenticide (thallium sulfide and zinc phosphide) in the area around where the birds had been found was revealed by a survey, etiological and pathological examinations including elemental analysis by means of particle induced X-ray emission (PIXE) were conducted. Elemental analysis showed high concentrations (56-365 dry-μg/g) of thallium in the lungs, gastric contents, intestines, livers and kidneys. Histopathological examination revealed vacuolar degeneration of hepatic cells and granular and/or hyaline droplet degeneration of renal tubular epithelia. The results suggest that the mass deaths were caused by thallium poisoning. (author)

  18. Multielemental analysis of ferromanganese nodules from Central Indian Ocean Basin by PIXE

    International Nuclear Information System (INIS)

    Dutta, R. K.; Vijayan, V.; Ghosh, S.; Chakravortty, V.

    1997-01-01

    Ferromanganese nodules found on the Ocean bed are complex heterogeneous mixtures of several components. Two nodules from Central Indian Ocean Basin (CIOB) were analysed by proton induced X-ray emission (PIXE) technique using 3UD Tandem pelletron. The precision and the accuracy of this technique for chemical analyses has been confirmed by analysing USGS Geological Standards. Thick sample targets were bombarded by 3 MeV protons for the multielemental analysis. GUPIX-96 software was used for spectral data analysis. Quantitative estimate of K, Ca, Tl, V, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Rb, Sr, Y, Zr, Mo, Ba, Ce, Tl and Pb has been ascertained. The occurrence of Ga, Ge, Rb and Zr in nodules from this region is reported for the first time. The role of manganese and iron oxide phases in determining the uptake of various trace elements from ocean water and bottom sediment pore water has been discussed. (author)

  19. Archaeological application of PIXE-PIGME analysis of admirality islands obsidians

    Energy Technology Data Exchange (ETDEWEB)

    Ambrose, W R [Australian National Univ., Canberra. Dept. of Prehistory; Duerden, P; Bird, J R [Australian Atomic Energy Commission Research Establishment, Lucas Heights

    1982-12-31

    Archaeological research on trade and exchange systems in Melanesia has been advanced by the application of chemical analysis to artefacts and their raw materials. Using the measurement of proton induced X-rays (PIXE) and gamma rays (PIGME), in an automated system, it has been possible to chemically characterise over 2000 obsidian specimens for up to 21 elements. The data analysis has shown that discrimination is possible between source sub-units within a related volcanic suite of sources. The source groups, and the artefacts belonging to them, can be quickly and confidently sorted by applying multivariate clustering and allocation procedures to the data. This work has also shown that obsidian was carried from sources to sites more than 400 km away, across a sea barrier, around 6000 years ago and more than 3000 km from the Bismark Archipelage to Vanuatu (New Hebrides) between 3000-4000 years ago.

  20. Obsidian sourcing studies in Papua New Guinea using PIXE-PIGME analysis

    International Nuclear Information System (INIS)

    Summerhayes, G.R.; Gosden, C.; Bird, R.; Hotchkis, M.; Specht, J.; Torrence, R.; Fullaga, R.

    1993-01-01

    Over 100 obsidian samples were analysed using PIXE-PIGME in 1990. These samples were collected during intensive surveys of the source areas around Talasea, Garua Island, and the Mopir area in 1988, 1989 and 1990. A ratio combination of 9 elements were used to separate out groups as per previous studies: F/Na, Al/Na, K/Fe, Ca/Fe, Mn/Fe, Rb/Fe, Y/Zr, Sr/Fe and Zr/Fe. In spite of variations in major elements, the close agreement between results for minor and trace elements concentrations in artefacts and known source material indicates that the provenance of each artefact can be reliably determined. This conclusion provides important validation of the use of ion beam analysis in artefact characterisation. ills

  1. Quantitative analysis of untreated oil samples in in-air PIXE

    International Nuclear Information System (INIS)

    Sera, K.; Goto, S.; Takahashi, C.; Saitoh, Y.

    2010-01-01

    The method of quantitative analysis of oil samples in in-air PIXE has been developed on the basis of a standard-free method. The components of the continuous X-rays originated from air and backing film can be exactly subtracted using a blank spectrum after normalization by the yields of Ar K-α X-rays. The method was developed using nine oil samples including standard oils and its accuracy was confirmed by comparing the results with those obtained by the internal-standard method. Validity of the method for practical oil samples was confirmed for various kinds of oils such as engine, machine and cooking oils. It was found that the method is effective for various kinds of oils whatever elements we designate as an index element. (author)

  2. Spatially resolved element analysis of historical violin varnishes by use of muPIXE.

    Science.gov (United States)

    von Bohlen, Alex; Röhrs, Stefan; Salomon, Joseph

    2007-02-01

    External muPIXE has been used for characterisation of small samples of varnish from historical violins, and pieces of varnished wood from historical and modern stringed instruments. To obtain spatially resolved information about the distribution of elements across the varnish layers single-spot analysis, line-scans, and area-mapping were performed. Local resolution of approximately 20 mum was obtained from the 3 MeV, 1 nA proton micro-probe. Results from simultaneous multi-element determination of Na, Mg, Al, Si, P, S, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Br, Rb, Sr, Ag, Cd, Sn, Ba, and Pb in historical varnishes are presented. Semi-quantitative evaluation of line-scans recorded on diverse historical varnishes is reported. The applied method is discussed in detail and the results obtained are critically reviewed and compared with those in the literature.

  3. Application of micro-PIXE to fish life history analyses: trace element analysis of otoliths

    International Nuclear Information System (INIS)

    Elfman, M.; Limburg, K.E.; Kristiansson, P.; Malmqvist, K.; Pallon, J.

    1999-01-01

    Otoliths are biogenic, carbonate concretions which form part of the hearing/balance system in fishes. The radial growth of otoliths and the variation of trace elements along the radius appear to capture important aspects of fishes' environmental history. At the Lund Nuclear Microprobe Laboratory, we have begun to use Proton-Induced X-ray Emission spectroscopy (PIXE) for micro-elemental analysis of otoliths. The experimental procedure is discussed and a number of examples of what can be investigated are presented. In particular, movement of diadromous species (eel, menhaden, and anadromous brown trout) can be detected between fresh and brackish water by Sr/Ca ratio. This technique has also been used to identify fish that were raised in freshwater hatcheries and then released to brackish water (pike-perch example)

  4. Obsidian sourcing studies in Papua New Guinea using PIXE-PIGME analysis

    Energy Technology Data Exchange (ETDEWEB)

    Summerhayes, G R; Gosden, C [La Trobe Univ., Bundoora, VIC (Australia); Bird, R; Hotchkis, M [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Specht, J; Torrence, R; Fullaga, R [Australian Museum, Sydney, NSW (Australia). Div. of Anthropology

    1994-12-31

    Over 100 obsidian samples were analysed using PIXE-PIGME in 1990. These samples were collected during intensive surveys of the source areas around Talasea, Garua Island, and the Mopir area in 1988, 1989 and 1990. A ratio combination of 9 elements were used to separate out groups as per previous studies: F/Na, Al/Na, K/Fe, Ca/Fe, Mn/Fe, Rb/Fe, Y/Zr, Sr/Fe and Zr/Fe. In spite of variations in major elements, the close agreement between results for minor and trace elements concentrations in artefacts and known source material indicates that the provenance of each artefact can be reliably determined. This conclusion provides important validation of the use of ion beam analysis in artefact characterisation. ills.

  5. Vertical distribution of particulate trace elements in a street canyon determined by PIXE analysis

    International Nuclear Information System (INIS)

    Raunemaa, T.; Hautojaervi, A.; Kaisla, K.; Gerlander, M.

    1981-01-01

    Suspended particles in a street canyon were investigated by collecting air particulate matter on thin filters at heigths 2.3 to 20.5 m. The weather parameters and traffic characteristics were registered during the collection. Quantitative analysis of 15 trace elements from AI to Pb was carried out by the PIXE method using 1.8-2.0 MeV protons. The concentration of lead was found to decrease exponentially when going from street level to roof level. Almost all the trace elements analyzed were found to fall into two groups with different vertical distributions. The collected matter above 10 m height was found to be due mainly to combustion originated motor vehicle exhaust, the matter below 10 m to soil originated dust. (orig.)

  6. Obsidian sourcing studies in Papua New Guinea using PIXE-PIGME analysis

    Energy Technology Data Exchange (ETDEWEB)

    Summerhayes, G.R.; Gosden, C. [La Trobe Univ., Bundoora, VIC (Australia); Bird, R.; Hotchkis, M. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Specht, J.; Torrence, R.; Fullaga, R. [Australian Museum, Sydney, NSW (Australia). Div. of Anthropology

    1993-12-31

    Over 100 obsidian samples were analysed using PIXE-PIGME in 1990. These samples were collected during intensive surveys of the source areas around Talasea, Garua Island, and the Mopir area in 1988, 1989 and 1990. A ratio combination of 9 elements were used to separate out groups as per previous studies: F/Na, Al/Na, K/Fe, Ca/Fe, Mn/Fe, Rb/Fe, Y/Zr, Sr/Fe and Zr/Fe. In spite of variations in major elements, the close agreement between results for minor and trace elements concentrations in artefacts and known source material indicates that the provenance of each artefact can be reliably determined. This conclusion provides important validation of the use of ion beam analysis in artefact characterisation. ills.

  7. Further results from PIXE analysis of inks in Galileo's notes on motion

    Science.gov (United States)

    Del Carmine, P.; Giuntini, L.; Hooper, W.; Lucarelli, F.; Mandò, P. A.

    1996-06-01

    We have recently analysed the inks in some of the folios of Vol. 72 of Manoscritti galileiani, kept at the Biblioteca Nazionale Centrale di Firenze, which contains a collection of loose handwritten sheets containing undated notes, data from experiments and propositions on the problems of motion from different periods of Galileo's life. This paper reports specific results obtained from the analysis of some of these propositions, which allowed to make a contribution to their chronological attribution and therefore to the solution of some historical controversies. Even in the case where the "absolute" chronological attributions could not be made on the basis of comparison with dated documents, the PIXE results provided useful information to deny or confirm the hypothesis that different propositions were written in the same or in different periods.

  8. PIXE and ICP-MS analysis of fenugreek medicinal plant from different regions

    International Nuclear Information System (INIS)

    Chandrasekhar Rao, J.; Naidu, B.G.; Sarita, P.; Naga Raju, G.J.

    2017-01-01

    Elemental analysis of Fenugreek medicinal plant collected from different regions was carried out by Proton Induced X-ray Emission (PIXE) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) techniques. The elements Li, Be, Al, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Br, Rb, Sr, Ag, Cd, Ba, Pb and U were identified and their concentrations were estimated. These elements were found to be in widely varying concentrations in the analyzed Fenugreek medicinal plant collected from different regions. of the. The results of the present study provide a better understanding of the pharmacological action of Fenugreek medicinal plant and it can also be used to set new standards for prescribing the dosage of herbal drugs. (author)

  9. PIXE analysis of chromium phytoaccumulation by the aquatic macrophytes Eicchornia crassipes

    International Nuclear Information System (INIS)

    Espinoza-Quinones, F.R.; Rizzutto, M.A.; Added, N.; Tabacniks, M.H.; Modenes, A.N.; Palacio, S.M.; Silva, E.A.; Rossi, F.L.; Martin, N.; Szymanski, N.

    2009-01-01

    The uptake of hexavalent chromium in free living floating aquatic macrophytes Eicchornia crassipes cultivated in non-toxic chromium-doped hydroponic solutions is presented. A Cr-uptake bioaccumulation experiment was carried out using healthy macrophytes grown in a temperature controlled greenhouse. Six samples of nutrient media and plants were collected during the 23 day experiment. Roots and leaves were acid digested with the addition of an internal Gallium standard, for thin film sample preparation and quantitative Cr analysis by PIXE method. The Cr 6+ mass uptake by the macrophytes reached up to 70% of the initial concentration, comparable to former results and literature data. The Cr-uptake data were described using a non-structural first order kinetic model. Due to low cost and high removal efficiency, living aquatic macrophytes E. crassipes are a viable biosorbent in an artificial wetland of a water effluent treatment plant.

  10. Extraction of metal ions using chemically modified silica gel: a PIXE analysis.

    Science.gov (United States)

    Jal, P K; Dutta, R K; Sudarshan, M; Saha, A; Bhattacharyya, S N; Chintalapudi, S N; K Mishra, B

    2001-08-30

    Organic ligand with carboxyhydrazide functional group was immobilised on the surface of silica gel and the metal binding capacity of the ligand-embedded silica was investigated. The functional group was covalently bonded to the silica matrix through a spacer of methylene groups by sequential reactions of silica gel with dibromobutane, malonic ester and hydrazine in different media. Surface area value of the modified silica was determined. The changes in surface area were correlated with the structural change of the silica surface due to chemical modifications. A mixture solution of metal ions [K(I),Cr(III),Co(II),Ni(II),Cu(II),Zn(II),Hg(II) and U(VI)] was treated with the ligand-embedded silica in 10(-3) M aqueous solution. The measurement of metal extraction capacity of the silica based ligand was done by multielemental analysis of the metal complexes thus formed by using Proton Induced X-ray Emission (PIXE) technique.

  11. Accelerator-Based PIXE and STIM Analysis of Candidate Solar Sail Materials

    International Nuclear Information System (INIS)

    Hollerman, W.A.; Stanaland, T.L.; Boudreaux, P.; Elberson, L.; Fontenot, J.; Gates, E.; Greco, R.; McBride, M.; Woodward, A.; Edwards, D.

    2003-01-01

    Solar sailing is a unique form of propulsion where a spacecraft gains momentum from incident photons. A totally reflective sail experiences a pressure of 9.1 μPa at a distance of 1 AU from the Sun. Since sails are not limited by reaction mass, they provide continual acceleration, reduced only by the lifetime of the lightweight film in the space environment and the distance to the Sun. Practical solar sails can expand the number of possible missions, enabling new concepts that are difficult by conventional means. One of the current challenges is to develop strong, lightweight, and radiation resistant sail materials. This paper will discuss initial results from a Particle Induced X-Ray Emission (PIXE) and Scanning Transmission Ion Microscopy (STIM) analysis of candidate solar sail materials

  12. Analysis of powdered milk by PIXE (Proton Induced X-ray Emission)

    International Nuclear Information System (INIS)

    Desales Galeana, G.

    1990-01-01

    The purpose of this work was to establish the conditions to analyze elements of Z>15 in powdered milk samples using the PIXE technique. Ten different commercial samples were analyzed: 2 full-cream, 3 half-cream and 5 for infant feeding. They were all purchased in Toluca City, Mexico. Thick targets were prepared and irradiated with 1.5 and 3 MeV protons beam in Mexico's Nuclear Center Tandem Van de Graff Accelerator. The obtained data were analyzed by two computers programs. Iron, the reference element was analyzed by atomic absorption spectrometry. Concentrations of the following elements: phosphorus, chlorine, potassium, calcium, chrome, iron, cobalt, nickel, copper, zinc, bromine, rubidium, molybdenum and cadmium were evaluated. The concentrations of the first four elements were usually high, whereas those of the other elements remained in some ppm. The experimental conditions set up in this work were suitable for the analysis of powdered milk and can be applied to other organic samples (Author)

  13. PIXE analysis of chromium phytoaccumulation by the aquatic macrophytes Eicchornia crassipes

    Energy Technology Data Exchange (ETDEWEB)

    Espinoza-Quinones, F.R. [Department of Chemical Engineering - Postgraduate Program - NBQ, West Parana State University, Rua da Faculdade, 645, Jardim Santa Maria, 85903-000 Toledo, Parana (Brazil)], E-mail: f.espinoza@terra.com.br; Rizzutto, M.A.; Added, N.; Tabacniks, M.H. [Physics Institute, University of Sao Paulo, Rua do Matao s/n, Travessa R 187, 05508-900 Sao Paulo, SP (Brazil); Modenes, A.N.; Palacio, S.M.; Silva, E.A.; Rossi, F.L.; Martin, N.; Szymanski, N. [Department of Chemical Engineering - Postgraduate Program - NBQ, West Parana State University, Rua da Faculdade, 645, Jardim Santa Maria, 85903-000 Toledo, Parana (Brazil)

    2009-04-15

    The uptake of hexavalent chromium in free living floating aquatic macrophytes Eicchornia crassipes cultivated in non-toxic chromium-doped hydroponic solutions is presented. A Cr-uptake bioaccumulation experiment was carried out using healthy macrophytes grown in a temperature controlled greenhouse. Six samples of nutrient media and plants were collected during the 23 day experiment. Roots and leaves were acid digested with the addition of an internal Gallium standard, for thin film sample preparation and quantitative Cr analysis by PIXE method. The Cr{sup 6+} mass uptake by the macrophytes reached up to 70% of the initial concentration, comparable to former results and literature data. The Cr-uptake data were described using a non-structural first order kinetic model. Due to low cost and high removal efficiency, living aquatic macrophytes E. crassipes are a viable biosorbent in an artificial wetland of a water effluent treatment plant.

  14. Analysis of elemental composition of porcelains unearthed from Waguantan kiln site by PIXE-RBS

    Science.gov (United States)

    Zhou, Z.; Zhang, K.; Xia, C. D.; Liu, M. T.; Zhu, J. J.; An, Z.; Bai, B.

    2015-03-01

    A method combining proton-induced X-ray emission spectrometry (PIXE) and Rutherford backscattering spectrometry (RBS) was used to determine the composition of 61 porcelain shards from the Yuan Dynasty (1271-1368 A.D.) unearthed from the Waguantan kiln site at Tianzhu County in Guizhou Province, China. Based on our previous experimental setup, an electron gun device with a LaB6 crystal cathode was installed to solve the problem created when the incident proton beams generated electric charge accumulations on the surfaces of the insulating porcelain samples, which induced a large bremsstrahlung background. The use of the electron gun has largely eliminated the large bremsstrahlung background and has therefore improved the detection limits for elements, especially for trace elements, and made it possible to determine the origin of the porcelains based on the trace elements. Major and trace elemental compositions of the porcelain bodies and glazes measured by PIXE and RBS were analyzed by the factor analysis method. The factor analysis showed that a few pieces of porcelain with a style similar to the porcelain of the Longquan kiln among the unearthed porcelains from the Waguantan kiln site did not have obvious differences in elemental compositions from other remaining porcelains unearthed from the Waguantan kiln site, indicating that the pieces of unearthed porcelain with the Longquan kiln style did in fact belong to the product fired locally by imitating the model of the Longquan celadon with local raw materials. This result therefore indicated that the Longquan kiln technology that originated from the Five Dynasties (907-960 A.D.) had been propagated to the Waguantan kiln site of Guizhou Province in the Yuan Dynasty.

  15. Evaluation of pressed powders and thin section standards for multi-elemental analysis by conventional and micro-PIXE analysis

    International Nuclear Information System (INIS)

    Homma-Takeda, Shino; Iso, Hiroyuki; Ito, Masaki

    2010-01-01

    For multi-elemental analysis, various standards are used to quantify the elements consists of environmental and biological samples. In this paper two different configuration standards, pressed powders and thin section standards, were assessed for their purpose as standards by conventional and micro-PIXE analysis. Homogeneity of manganese, iron, zinc (Zn), copper and yttrium added to pressed powder standard materials were validated and the relative standard deviation (RSD) of the X-ray intensity of the standards was 2 area and the metal concentration was acceptable. (author)

  16. Analysis of an Electrostatic MEMS Squeeze-film Drop Ejector

    Directory of Open Access Journals (Sweden)

    Edward P. Furlani

    2009-10-01

    Full Text Available We present an analysis of an electrostatic drop-on-demand MEMS fluid ejector. The ejector consists of a microfluidic chamber with a piston that is suspended a few microns beneath a nozzle plate. A drop is ejected when a voltage is applied between the orifice plate and the piston. This produces an electrostatic force that moves the piston towards the nozzle. The moving piston generates a squeeze-film pressure distribution that causes drop ejection. We discuss the operating physics of the ejector and present a lumped-element model for predicting its performance. We calibrate the model using coupled structural-fluidic CFD analysis.

  17. Artificial neural networks applied to quantitative elemental analysis of organic material using PIXE

    International Nuclear Information System (INIS)

    Correa, R.; Chesta, M.A.; Morales, J.R.; Dinator, M.I.; Requena, I.; Vila, I.

    2006-01-01

    An artificial neural network (ANN) has been trained with real-sample PIXE (particle X-ray induced emission) spectra of organic substances. Following the training stage ANN was applied to a subset of similar samples thus obtaining the elemental concentrations in muscle, liver and gills of Cyprinus carpio. Concentrations obtained with the ANN method are in full agreement with results from one standard analytical procedure, showing the high potentiality of ANN in PIXE quantitative analyses

  18. Artificial neural networks applied to quantitative elemental analysis of organic material using PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Correa, R. [Universidad Tecnologica Metropolitana, Departamento de Fisica, Av. Jose Pedro Alessandri 1242, Nunoa, Santiago (Chile)]. E-mail: rcorrea@utem.cl; Chesta, M.A. [Universidad Nacional de Cordoba, Facultad de Matematica, Astronomia y Fisica, Medina Allende s/n Ciudad Universitaria, 5000 Cordoba (Argentina)]. E-mail: chesta@famaf.unc.edu.ar; Morales, J.R. [Universidad de Chile, Facultad de Ciencias, Departamento de Fisica, Las Palmeras 3425, Nunoa, Santiago (Chile)]. E-mail: rmorales@uchile.cl; Dinator, M.I. [Universidad de Chile, Facultad de Ciencias, Departamento de Fisica, Las Palmeras 3425, Nunoa, Santiago (Chile)]. E-mail: mdinator@uchile.cl; Requena, I. [Universidad de Granada, Departamento de Ciencias de la Computacion e Inteligencia Artificial, Daniel Saucedo Aranda s/n, 18071 Granada (Spain)]. E-mail: requena@decsai.ugr.es; Vila, I. [Universidad de Chile, Facultad de Ciencias, Departamento de Ecologia, Las Palmeras 3425, Nunoa, Santiago (Chile)]. E-mail: limnolog@uchile.cl

    2006-08-15

    An artificial neural network (ANN) has been trained with real-sample PIXE (particle X-ray induced emission) spectra of organic substances. Following the training stage ANN was applied to a subset of similar samples thus obtaining the elemental concentrations in muscle, liver and gills of Cyprinus carpio. Concentrations obtained with the ANN method are in full agreement with results from one standard analytical procedure, showing the high potentiality of ANN in PIXE quantitative analyses.

  19. Aerosol composition and source apportionment in the Mexico City Metropolitan Area with PIXE/PESA/STIM and multivariate analysis

    Directory of Open Access Journals (Sweden)

    K. S. Johnson

    2006-01-01

    Full Text Available Aerosols play an important role in the atmosphere but are poorly characterized, particularly in urban areas like the Mexico City Metropolitan Area (MCMA. The chemical composition of urban particles must be known to assess their effects on the environment, and specific particulate emissions sources should be identified to establish effective pollution control standards. For these reasons, samples of particulate matter ≤2.5 μm (PM2.5 were collected during the MCMA-2003 Field Campaign for elemental and multivariate analyses. Proton-Induced X-ray Emission (PIXE, Proton-Elastic Scattering Analysis (PESA and Scanning Transmission Ion Microscopy (STIM measurements were done to determine concentrations of 19 elements from Na to Pb, hydrogen, and total mass, respectively. The most abundant elements from PIXE analysis were S, Si, K, Fe, Ca, and Al, while the major emissions sources associated with these elements were industry, wind-blown soil, and biomass burning. Wind trajectories suggest that metals associated with industrial emissions came from northern areas of the city whereas soil aerosols came from the southwest and increased in concentration during dry conditions. Elemental markers for fuel oil combustion, V and Ni, correlated with a large SO2 plume to suggest an anthropogenic, rather than volcanic, emissions source. By subtracting major components of soil and sulfates determined by PIXE analysis from STIM total mass measurements, we estimate that approximately 50% of non-volatile PM2.5 consisted of carbonaceous material.

  20. High Resolution and Differential PIXE combined with RBS, EBS and AFM analysis of magnesium titanate (MgTiO3) multilayer structures

    International Nuclear Information System (INIS)

    Reis, M.A.; Alves, L.C.; Barradas, N.P.; Chaves, P.C.; Nunes, B.; Taborda, A.; Surendran, K.P.; Wu, A.; Vilarinho, P.M.; Alves, E.

    2010-01-01

    Thorough structural characterization of deep laying thin film, including the inference of interdiffusion profiles is frequently a complex problem. The use of RBS/PIXE holistic approaches, already shown to represent a powerful method, sometimes faces difficulties if standard experimental procedures are used. In this work, following a series of 4 He Rutherford backscattering and 1 H elastic backscattering experiments, carried out to study the influence of SrTiO 3 as a possible cladding layer between Pt/TiO 2 /SiO 2 /(1 0 0)Si substrates and MgTiO 3 films, a simple holistic RBS-PIXE is shown to be not enough for the solution of such a problem. Establishing of the Sr depth profile, was only possible after AFM, High-Resolution EDS PIXE and differential PIXE analysis were carried out. Results, problems faced and conclusions obtained are presented.

  1. Comparative trace elemental analysis of cancerous and non-cancerous tissues of rectal cancer patients using PIXE

    Science.gov (United States)

    Naga Raju, G. J.; Sarita, P.; Murthy, K. S. R.

    2017-08-01

    Particle Induced X-ray Emission (PIXE), an accelerator based analytical technique has been employed in this work for the analysis of trace elements in the cancerous and non-cancerous tissues of rectal cancer patients. A beam of 3 MeV protons generated from 3 MV Pelletron accelerator at the Ion Beam Laboratory of Institute of Physics, Bhubaneswar, India was used as projectile to excite the atoms present in the tissues samples. PIXE technique, with its capability to detect simultaneously several elements present at very low concentrations, offers an excellent tool for trace element analysis. The characteristic X-rays emitted by the samples were recorded by a high resolution Si (Li) detector. On the basis of the PIXE spectrum obtained for each sample, the elements Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, and Br were identified and their relative concentrations were estimated in the cancerous and non-cancerous tissues of rectum. The levels of Mn, Fe, Co, Cu, Zn, and As were higher (p < 0.005) while the levels of Ca, Cr and Ni were lower (p < 0.005) in the cancer tissues relative to the normal tissues. The alterations in the levels of the trace elements observed in the present work are discussed in this paper with respect to their potential role in the initiation, promotion and inhibition of cancer of the rectum.

  2. Comparison of PIXE and XRF analysis of airborne particulate matter samples collected on Teflon and quartz fibre filters

    Science.gov (United States)

    Chiari, M.; Yubero, E.; Calzolai, G.; Lucarelli, F.; Crespo, J.; Galindo, N.; Nicolás, J. F.; Giannoni, M.; Nava, S.

    2018-02-01

    Within the framework of research projects focusing on the sampling and analysis of airborne particulate matter, Particle Induced X-ray Emission (PIXE) and Energy Dispersive X-ray Fluorescence (ED-XRF) techniques are routinely used in many laboratories throughout the world to determine the elemental concentration of the particulate matter samples. In this work an inter-laboratory comparison of the results obtained from analysing several samples (collected on both Teflon and quartz fibre filters) using both techniques is presented. The samples were analysed by PIXE (in Florence, at the 3 MV Tandetron accelerator of INFN-LABEC laboratory) and by XRF (in Elche, using the ARL Quant'X EDXRF spectrometer with specific conditions optimized for specific groups of elements). The results from the two sets of measurements are in good agreement for all the analysed samples, thus validating the use of the ARL Quant'X EDXRF spectrometer and the selected measurement protocol for the analysis of aerosol samples. Moreover, thanks to the comparison of PIXE and XRF results on Teflon and quartz fibre filters, possible self-absorption effects due to the penetration of the aerosol particles inside the quartz fibre-filters were quantified.

  3. PIXE analysis of pre-colonial pottery from Sambaqui do Panaquatira

    International Nuclear Information System (INIS)

    Ikeoka, R.A.; Appoloni, C.R.; Rizzutto, M.A.; Silva, T.F.; Bandeira, A.M.

    2013-01-01

    Full text: The study of cultural heritage of ancient people through fossils, monuments and engines has fundamental importance in the construction of the memory of any society. Such knowledge can be acquired by researches in archaeological sites and the detailed study of the different kind of objects which can be found in these places. This work deals with objects from the Sambaqui of Panaquatira located in Sao Luis do Maranhao (Brazil). Ancient civilizations that inhabited that territory were characterized as fishing populations - catchers - hunters and ceramists. From a selection of 95 pottery fragments of surface; 5 to 10 cm; 20 to 30 cm; 40 to 50 cm; 65 to 70 cm; 80 to 90 cm; 90 to 100 cm; 130 to 140 cm and 160 to 170 cm stratigraphic levels, a representative set was analyzed using Particle Induced X-ray Emission (PIXE) methodology. PIXE measurements were performed with an external beam setup with ~2.4 MeV proton beam in the LAMFI laboratory using three X-ray detectors, two Si-PIN detectors and one HPGe with standard spectrometry electronics; each spectrum was taken for 600s. The spectra analyses were performed with the Quantitative X-Ray Analysis Software (WinQXAS), distributed by International Atomic Energy Agency (IAEA). The elements Si, P, S, CI, K, Ca, Ti, Cr, Mn, Fe and Zn were identified in the different fragments. It was analysed the kind of applied treatment on the concave and convex sides in relation to the ceramic paste of the fragments. From the determination of the elemental composition of the fragments, it was possible to identify that the elements Ti, Mn, Fe and Zn are present in the fragments with larger amounts at concave and convex sides, compared to the ceramic paste, indicating a different surface treatment that leads to an enrichment of these elements. One fragment from the 20-25cm stratigraphy has a lighter colour region which is characterized by containing the highest concentration of the elements Ti, Ca, Ti, Cr and Mn. (author)

  4. PIXE analysis of pre-colonial pottery from Sambaqui do Panaquatira

    Energy Technology Data Exchange (ETDEWEB)

    Ikeoka, R.A.; Appoloni, C.R., E-mail: renatoikeoka@yahoo.com.br [Universidade Estadual de Londrina (CCE/UEL), PR (Brazil). Departamento de Fisica; Rizzutto, M.A.; Silva, T.F. [Universidade de Sao Paulo (LAMFI/USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Laboratorio de Analise de Materiais por Feixes Ionicos; Bandeira, A.M. [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Museu de Arqueologia e Etnologia

    2013-07-01

    Full text: The study of cultural heritage of ancient people through fossils, monuments and engines has fundamental importance in the construction of the memory of any society. Such knowledge can be acquired by researches in archaeological sites and the detailed study of the different kind of objects which can be found in these places. This work deals with objects from the Sambaqui of Panaquatira located in Sao Luis do Maranhao (Brazil). Ancient civilizations that inhabited that territory were characterized as fishing populations - catchers - hunters and ceramists. From a selection of 95 pottery fragments of surface; 5 to 10 cm; 20 to 30 cm; 40 to 50 cm; 65 to 70 cm; 80 to 90 cm; 90 to 100 cm; 130 to 140 cm and 160 to 170 cm stratigraphic levels, a representative set was analyzed using Particle Induced X-ray Emission (PIXE) methodology. PIXE measurements were performed with an external beam setup with ~2.4 MeV proton beam in the LAMFI laboratory using three X-ray detectors, two Si-PIN detectors and one HPGe with standard spectrometry electronics; each spectrum was taken for 600s. The spectra analyses were performed with the Quantitative X-Ray Analysis Software (WinQXAS), distributed by International Atomic Energy Agency (IAEA). The elements Si, P, S, CI, K, Ca, Ti, Cr, Mn, Fe and Zn were identified in the different fragments. It was analysed the kind of applied treatment on the concave and convex sides in relation to the ceramic paste of the fragments. From the determination of the elemental composition of the fragments, it was possible to identify that the elements Ti, Mn, Fe and Zn are present in the fragments with larger amounts at concave and convex sides, compared to the ceramic paste, indicating a different surface treatment that leads to an enrichment of these elements. One fragment from the 20-25cm stratigraphy has a lighter colour region which is characterized by containing the highest concentration of the elements Ti, Ca, Ti, Cr and Mn. (author)

  5. Elemental analysis of edible grains by micro-PIXE: Common buckwheat case study

    Energy Technology Data Exchange (ETDEWEB)

    Vogel-Mikus, K. [Biotechnical Faculty, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Pelicon, P.; Vavpetic, P. [Jozef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Kreft, I. [Biotechnical Faculty, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia)], E-mail: ivan.kreft@guest.arnes.si; Regvar, M. [Biotechnical Faculty, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia)

    2009-09-01

    The aim of this study was the adaptation of the micro-PIXE method for analysis of nutritionally relevant heavy elements in different tissues of the grain of common buckwheat (Fagopyrum esculentum), as a representative nutritionally interesting grain food source. At 57% of the buckwheat grain biomass, the endosperm was a modest nutrient source when compared to the cotyledons, at 17% of the biomass. These latter contained high concentrations of trace elements, representing 91% of the total grain Zn, 87% for P, 70% for S, 62% for Mg, 60% for K, 54% for Cu, 53% for Mn and 35% for Fe. The husk provided storage for 85% of the total Ca, 84% for Al, 83% for Si, 76% for Cl, 69% for Ti and 46% for Fe. Knowledge on these preferential elemental constitutions of the different grain tissues makes the possibility of designing target products with nutritionally optimal constitution more feasible. These data represent a basis for a more targeted approach to nutritional improvement of grains intended for human consumption.

  6. Elemental analysis of edible grains by micro-PIXE: Common buckwheat case study

    International Nuclear Information System (INIS)

    Vogel-Mikus, K.; Pelicon, P.; Vavpetic, P.; Kreft, I.; Regvar, M.

    2009-01-01

    The aim of this study was the adaptation of the micro-PIXE method for analysis of nutritionally relevant heavy elements in different tissues of the grain of common buckwheat (Fagopyrum esculentum), as a representative nutritionally interesting grain food source. At 57% of the buckwheat grain biomass, the endosperm was a modest nutrient source when compared to the cotyledons, at 17% of the biomass. These latter contained high concentrations of trace elements, representing 91% of the total grain Zn, 87% for P, 70% for S, 62% for Mg, 60% for K, 54% for Cu, 53% for Mn and 35% for Fe. The husk provided storage for 85% of the total Ca, 84% for Al, 83% for Si, 76% for Cl, 69% for Ti and 46% for Fe. Knowledge on these preferential elemental constitutions of the different grain tissues makes the possibility of designing target products with nutritionally optimal constitution more feasible. These data represent a basis for a more targeted approach to nutritional improvement of grains intended for human consumption.

  7. Optimisation of Pt sensitivity in PIXE analysis of thin biological samples

    International Nuclear Information System (INIS)

    Tiourina, T.B.; Mutsaers, P.H.A.; Voigt, M.J.A. de

    1998-01-01

    To obtain Pt concentration distributions in tumor biopsies, micro-PIXE is used. The limit of detection (LOD) for Pt is determined by the background production cross section together with the production cross section for the Pt-L lines. Both are functions of the type and energy of the projectile. In order to optimise the experimental conditions, the proton energy is varied from 2.5 to 5 MeV and the corresponding X-ray spectra are analysed. The optimum LOD is about 1 μg/g for a sample thickness of 1 mg/cm 2 and a total charge of 100 μC. A study is performed to investigate the possibility of elemental analysis by means of α excitation. The corresponding LOD is 6 μg/g with 200 μC charge (He ++ was used). For α excitation, sample damage limits the beam current and, thus, causes a tremendous increase in the measurement time. (orig.)

  8. PIXE and ICP analysis of chemical elements in the downer cow syndrome

    International Nuclear Information System (INIS)

    Dima, G.; Stihi, C.; Popescu, I. V.; Badica, T.; Olariu, A.; Petre, M.; Jianu, E. D.

    2001-01-01

    The aim of this study was the microelemental analysis of blood serum samples collected from healthy and ill cows (downer cow syndrome DCS). The origin of this syndrome is uncertain but the clinical experience denotes that the DCS is advanced by the hypocalcaemic paresis of parturition. The diminution of some nutritive elements from food can be a cause of DCS. The cows are more sensitive to the diminution of P in food in comparison with the diminution of Ca. Another interesting aspect about the origin of DCS is the ratio Ca/P in food. The samples were collected from cows at some animal farms: 20 healthy cows and 12 DCS cows breeds on the same conditions. Concentrations of P, Cl, K, Ca and Fe elements were obtained by using particle induced X - ray emission (PIXE) and inductively coupled plasma (ICP). The mineral concentrations in the serum have values in normal limits for healthy cows even during the winter, when the mineral content of dry food is very poor. On the other hand, we can observe important decreases under the normal limits of the amount of Ca, P and Mg in the blood serum of DCS cows. It is easy to see the tendency of the DCS animals to have hypocalcemia and hypophosphataemia. Those perturbations can be the causes of the installations of the ill cows in the lypostatic and decubital attitudes. (authors)

  9. PIXE and ICP-AES analysis of early glass unearthed from Xinjiang (China)

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, B. [Department of Technical Physics, School of Physics, Peking University, Beijing 100871 (China); Cheng, H.S. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China)]. E-mail: hscheng@fudan.edu.cn; Ma, B. [School of Information Science and Engineering, Fudan University, Shanghai 200433 (China); Li, Q.H. [Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Zhang, P. [Xinjiang Institute of Archaeology, Urumchi 830011 (China); Gan, F.X. [School of Information Science and Engineering, Fudan University, Shanghai 200433 (China); Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Yang, F.J. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China)

    2005-10-15

    Early glasses (about 1066 BC-220 AD) unearthed from Xinjiang of China were chemically characterized by using PIXE and ICP-AES. It was found that these glasses were basically attributed to PbO-BaO-SiO{sub 2} system, K{sub 2}O-SiO{sub 2} system, Na{sub 2}O-CaO-SiO{sub 2} system and Na{sub 2}O-CaO-PbO-SiO{sub 2} system. The results from the cluster analysis showed that some glasses had basically similar recipe and technology. The PbO-BaO-SiO{sub 2} glass and the K{sub 2}O-SiO{sub 2} glass were thought to come from the central area and the south of ancient China, respectively. The part of the Na{sub 2}O-CaO-SiO{sub 2} glass (including the Na{sub 2}O-CaO-PbO-SiO{sub 2} glass) might be imported from Mesopotamia, while the other part might be locally produced.

  10. A Milliprobe for PIXE and PIGE Analysis used for the Study of Colour-Zoned Tourmaline

    Science.gov (United States)

    Mateus, R.; Alves, L. C.; Jesus, A. P.; Faria, A. F.; Ribeiro, J. P.

    2005-01-01

    A "milliprobe" system was implemented by using the focusing properties of a Van de Graaff accelerator, together with a collimator system including 1 mm diameter apertures, to impose the appropriate dimension to the beam spot. The scanning of the sample surface was achieved by X-Y movements of the sample holder (the Z axis being coincident with the beam direction). These movements were accomplished by a motorised X-Y table, with a travel of 25 mm × 25 mm, connected to the sample holder. This system was used to study specimens of the mineral tourmaline. Two samples, of the "watermelon" zoned tourmaline variety, originating from the Alto Ligonha pegmatite district in northern Mozambique, were analysed by the simultaneous use of PIXE (Proton-Induced X-Ray Emission) and PIGE (Proton-Induced Gamma-Ray Emission) techniques, in order to quantify their composition and try to establish a correlation between the elements (major and trace elements) and colour zoning. In order to validate the "milliprobe" analysis and study in more detail the frontier between zones of different colours, a microprobe analysis of the samples was also done. In this work, the mineralogical classification of the samples was accomplished. A correlation was established between the presence of Fe and green colour. It was also concluded that the presence of Mn by itself is not enough to lead to pink colour, which gives support to previous studies that claim that only Mn3+ and not the more common form Mn2+ is responsible for the pink colour.

  11. A Milliprobe for PIXE and PIGE Analysis used for the Study of Colour-Zoned Tourmaline

    Energy Technology Data Exchange (ETDEWEB)

    Mateus, R.; Alves, L.C.; Jesus, A.P.; Faria, A.F.; Ribeiro, J.P. [Univ. de Lisboa (Portugal). Centro de Fisica Nuclear

    2005-07-01

    A 'milliprobe' system was implemented by using the focusing properties of a Van de Graaff accelerator, together with a collimator system including 1mm diameter apertures, to impose the appropriate dimension to the beam spot. The scanning of the sample surface was achieved by X-Y movements of the sample holder (the Z axis being coincident with the beam direction). These movements were accomplished by a motorised X-Y table, with a travel of 25mmx25mm, connected to the sample holder. This system was used to study specimens of the mineral tourmaline. Two samples, of the 'watermelon' zoned tourmaline variety, originating from the Alto Ligonha pegmatite district in northern Mozambique, were analysed by the simultaneous use of PIXE (Proton-Induced X-Ray Emission) and PIGE (Proton-Induced Gamma-Ray Emission) techniques, in order to quantify their composition and try to establish a correlation between the elements (major and trace elements) and colour zoning. In order to validate the 'milliprobe' analysis and study in more detail the frontier between zones of different colours, a microprobe analysis of the samples was also done. In this work, the mineralogical classification of the samples was accomplished. A correlation was established between the presence of Fe and green colour. It was also concluded that the presence of Mn by itself is not enough to lead to pink colour, which gives support to previous studies that claim that only Mn{sup 3+} and not the more common form Mn{sup 2+} is responsible for the pink colour.

  12. Multivariate statistical treatment of PIXE analysis of some traditional Chinese medicines

    International Nuclear Information System (INIS)

    Xiaofeng Zhang; Jianguo Ma; Junfa Qin; Lun Xiao

    1991-01-01

    Elements in two kinds of 30 traditional Chinese medicines were analyzed by PIXE method, and the data were treated by multivariate statistical methods. The results show that these two kinds of traditional Chinese medicines are almost separable according to their elemental contents. The results are congruous with the traditional Chinese medicine practice. (author) 7 refs.; 2 figs.; 2 tabs

  13. Trace elemental analysis of Indian natural moonstone gems by PIXE and XRD techniques.

    Science.gov (United States)

    Venkateswara Rao, R; Venkateswarulu, P; Kasipathi, C; Sivajyothi, S

    2013-12-01

    A selected number of Indian Eastern Ghats natural moonstone gems were studied with a powerful nuclear analytical and non-destructive Proton Induced X-ray Emission (PIXE) technique. Thirteen elements, including V, Co, Ni, Zn, Ga, Ba and Pb, were identified in these moonstones and may be useful in interpreting the various geochemical conditions and the probable cause of their inceptions in the moonstone gemstone matrix. Furthermore, preliminary XRD studies of different moonstone patterns were performed. The PIXE technique is a powerful method for quickly determining the elemental concentration of a substance. A 3MeV proton beam was employed to excite the samples. The chemical constituents of moonstones from parts of the Eastern Ghats geological formations of Andhra Pradesh, India were determined, and gemological studies were performed on those gems. The crystal structure and the lattice parameters of the moonstones were estimated using X-Ray Diffraction studies, trace and minor elements were determined using the PIXE technique, and major compositional elements were confirmed by XRD. In the present work, the usefulness and versatility of the PIXE technique for research in geo-scientific methodology is established. © 2013 Elsevier Ltd. All rights reserved.

  14. The quantitative analysis of Bowen's kale by PIXE using the internal standard

    International Nuclear Information System (INIS)

    Navarrete, V.R.; Izawa, G.; Shiokawa, T.; Kamiya, M.; Morita, S.

    1978-01-01

    The internal standard method was used for non-destructive quantitative determination of trace elements by PIXE. The uniform distribution of the internal standard element in the Bowen's kale powder sample was obtained by using homogenization technique. Eleven elements are determined quantitatively for the sample prepared into self-supporting targets having lower relative standard deviations than non-self-supporting targets. (author)

  15. The identification of Chenghua white and blue porcelain by using PIXE and multivariate statistical analysis

    International Nuclear Information System (INIS)

    Cheng Huansheng; Zhang Zhengquan; Yao Hua

    2001-01-01

    The major and minor chemical compositions of ancient white and blue porcelain made in Chenghua empire, Ming Dynasty and in Kangxi empire, Qing Dynasty have been determined by PIXE. Experimental results show that a real precious Chenghua white and blue porcelain made in Ming Dynasty at Kuan Kiln can be distinguished from the fakes made in Kangxi empire, Qing Dynasty

  16. PIXE and ICP-AES comparison in evaluating the efficiency of metal extraction and analysis in aerosol samples

    Energy Technology Data Exchange (ETDEWEB)

    Rugi, F.; Becagli, S.; Ghedini, C.; Marconi, M.; Severi, M.; Traversi, R.; Udisti, R. [Dep. of Chemistry, University of Florence, Sesto F.no (Fl) (Italy); Calzolai, G.; Chiari, M.; Lucarelli, F.; Nava, S. [Dep. of Physics and Astronomy , University of Florence and INFN, Sesto F. no (Fl) (Italy)

    2013-07-01

    Full text: A recent EU regulation (EN 149022005) requests the quantification of selected metals in the atmospheric particulate by mineralization with H{sub 2}0{sub 2} and HN0{sub 3} in microwave oven.This method might possibly conflict with the determination of the total metal content. In fact, the more the aerosol is enriched in crustal elements the more the difference in the two methods are expected, since the H{sub 2}0{sub 2}+ HN0{sub 3}, extraction is not reliable for metals in silicate form. In order to evaluate the extracted fraction, PIXE and ICP-AES measurements were carried out on the two halves of a series of PM10 and PM2.5 samples collected on Teflon filters in an urban site in the surrounding of Florence (Italy). An ICP-AES (Inductively Coupled Plasma -Atomic Emission Spectroscopy) method was optimized by an ultrasound nebuliser (CETAC 5000 AT+), in order to improve reproducibility and detection limit. In these conditions, it was possible quantifying AI, As, Cr, Cu, Fe, Mn, Ni, Pb and Vatsub-ppb levels. PIXE analysis using the external beam set-up at LABEC and a 3 MeV proton beam was carried out in order to measure the total elemental content of the metals. By comparing the ICP-AES and the PIXE results, a preliminary evaluation of the efficiency of the H{sub 2}0{sub 2} and HN0{sub 3} extraction method was performed. The obtained results (the mean values for the ICP-AES/PIXE ratio are reported in Table 1) show that the extraction procedure following the EN 14902 directive allows quantitative recoveries (80-120%, including the analytical uncertainties)for the majority of the analysed metals, especially for those mainly emitted by anthropic sources. This result points out that anthropic metals are present in the atmosphere as relatively available species (free metals, labile complexes, carbonates, oxides). On the contrary, lower recoveries were obtained for AI (mean value around 75%), a metal that has a relevant crustal fraction. Percentage of recovery of

  17. Trace element analysis of wild rodent tissues using the PIXE method

    International Nuclear Information System (INIS)

    Hill, M.W.; Mangelson, N.F.; Ryder, J.F.; Atwood, N.D.; Wood, B.W.

    1980-01-01

    Five species of rodents have been collected in an area near Lake Powell Utah. Common names of the five species are: Long-tailed Mouse, Small Pocket Mouse, Deer Mouse, Antelope Ground Squirrel and Kangaroo Rat. Liver, lung, kidney and hair tissues from each animal were analyzed for trace element content by proton particle-induced x-ray emission (proton PIXE) analysis. Mean concentrations for the following elements were established for the tissues of each animal type: K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Se, Br, Rb and Pb. Analyses of variance were performed on the set of elements common to all tissues. Some significant differences in element concentrations were found between animal species and between tissue types. These differences lead to the following orders based on element concentration: Long-tailed Mouse greater than or equal to Antelope Ground Squirrel greater than or equal to Kangaroo Rat greater than or equal to Small Pocket Mouse and liver greater than or equal to kidney greater than or equal to lung greater than or equal to hair. Linear regression analyses were also performed on mean elemental concentrations in tissues. These analyses lead to several conclusions. First, the pattern of trace element concentrations in each of the four tissues is the same in all five species. Second, the pattern of trace element concentrations is the same in all four tissues of one species with the exception of Ti and Fe in hair. Third, the variation of an element in the hair cannot predict the variation of that same element in the other three tissues. Only K, Ca, Ti, Mn, Fe, Cu, and Zn were included in the third study

  18. PIXE in cultural heritage studies: present role and new challenges

    International Nuclear Information System (INIS)

    Calligaro, T.; Dran, J.-C.

    2013-01-01

    concentration is, for instance, fundamental for the determination of many ancient materials like glasses, ceramics or rocks. Seamless quantization. In general, the accurate determination of the composition of complex samples containing a 'dark matrix' - i.e. elements not appearing in the X-ray spectrum like hydrogen, carbon, oxygen - is more easily and accurately obtained using PIXE than XRF that suffers from pronounced matrix effects (critical dependency of X-ray yields with regard to the concentration of unknown elements). Better control of excitation volume. The fact that the PIXE emission probing depth is limited by the particle range allows to better control of the depth of analysis (analysis of surface layers on top of substrates like glazes on ceramics). Furthermore, some depth information, not available using XRF, can be gained with PIXE by varying the incident particle energy. Probe focusing and scanning. Unlike X-ray beams, particle beams are easily focused and deviated using magnetic and electrostatic fields. This provides interesting imaging capabilities in particular a fast scanning of the beam at the surface of the object to acquire compositional maps in a short time. Simultaneous combination with other IBA techniques. During the same irradiation RBS can deliver the layer thickness in the same area, PIGE the concentration of very light elements like lithium, beryllium, boron or fluorine, and non-Rutherford BS that of carbon and oxygen. A serious challenge is however posed by cultural heritage materials prone to damage by particle beams. It is the case of organic compounds - binder and varnish - or white lead pigments composing paint works. Since damage appears as linked to the beam fluence, a way to overcome this serious drawback is to perform PIXE using a low intensely beam spread over a large surface using fast scanning compensated by an improved detection efficiency. (author)

  19. PIXE in cultural heritage studies: present role and new challenges

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T.; Dran, J.-C. [Centre de Recherche et de Restauration des Musées de France, Palais du Louvre, Paris (France)

    2013-07-01

    concentration is, for instance, fundamental for the determination of many ancient materials like glasses, ceramics or rocks. Seamless quantization. In general, the accurate determination of the composition of complex samples containing a 'dark matrix' - i.e. elements not appearing in the X-ray spectrum like hydrogen, carbon, oxygen - is more easily and accurately obtained using PIXE than XRF that suffers from pronounced matrix effects (critical dependency of X-ray yields with regard to the concentration of unknown elements). Better control of excitation volume. The fact that the PIXE emission probing depth is limited by the particle range allows to better control of the depth of analysis (analysis of surface layers on top of substrates like glazes on ceramics). Furthermore, some depth information, not available using XRF, can be gained with PIXE by varying the incident particle energy. Probe focusing and scanning. Unlike X-ray beams, particle beams are easily focused and deviated using magnetic and electrostatic fields. This provides interesting imaging capabilities in particular a fast scanning of the beam at the surface of the object to acquire compositional maps in a short time. Simultaneous combination with other IBA techniques. During the same irradiation RBS can deliver the layer thickness in the same area, PIGE the concentration of very light elements like lithium, beryllium, boron or fluorine, and non-Rutherford BS that of carbon and oxygen. A serious challenge is however posed by cultural heritage materials prone to damage by particle beams. It is the case of organic compounds - binder and varnish - or white lead pigments composing paint works. Since damage appears as linked to the beam fluence, a way to overcome this serious drawback is to perform PIXE using a low intensely beam spread over a large surface using fast scanning compensated by an improved detection efficiency. (author)

  20. PIXE analysis of mineral composition of alfalfa root-tip exposed to low pH or aluminum stress condition

    International Nuclear Information System (INIS)

    Yokota, Satoshi; Mae, Tadahiko; Ojima, Kunihiko; Ishii, Keizo.

    1994-01-01

    PIXE analysis was applied to study alteration of mineral composition (Al, P, K, and Cl) of alfalfa root-tip exposed to low pH or aluminum stress. These minerals were detectable using one or two pieces of root-tips. Short-term (within 4 h) decreases in K/P and Cl/P ratios were observed under low pH and aluminum stress conditions. However, degree of the decrease was not same. Differences in toxic effects of low pH and Al on the root-tip of alfalfa are discussed. (author)

  1. The application of XRF and PIXE in the analysis of rice shoot and compositional screening of genotypes

    Energy Technology Data Exchange (ETDEWEB)

    Bado, S., E-mail: s.bado@iaea.org [Plant Breeding and Genetics Laboratory (PGBL), International Atomic Energy (IAEA), Vienna (Austria); Padilla-Alvarez, R., E-mail: rpa2000up@hotmail.com [Nuclear Science and Instrumentation Laboratory (NSIL), International Atomic Energy Agency (IAEA), Vienna International Centre, PO Box 100, 1400 Vienna (Austria); Migliori, A. [Nuclear Science and Instrumentation Laboratory (NSIL), International Atomic Energy Agency (IAEA), Vienna International Centre, PO Box 100, 1400 Vienna (Austria); Forster, B.P., E-mail: brianforster@biohybrids.com [Plant Breeding and Genetics Laboratory (PGBL), International Atomic Energy (IAEA), Vienna (Austria); Jaksic, M., E-mail: jaksic@irb.hr [Institut Ruđer Bošković, Bijenička cesta 54, 10000 Zagreb (Croatia); Diawara, Y.; Kaiser, R. [Nuclear Science and Instrumentation Laboratory (NSIL), International Atomic Energy Agency (IAEA), Vienna International Centre, PO Box 100, 1400 Vienna (Austria); Laimer, M., E-mail: margit.laimer@boku.ac.at [Plant Biotechnology Unit, Department of Biotechnology, University of Natural Resources and Life Sciences, Muthgasse 18, A 1190 Vienna (Austria)

    2016-03-15

    The analytical performance of Particle Induced X-ray Emission (PIXE) and X-ray Fluorescence (XRF) techniques was assessed in the determination of fourteen elements (Na, Mg, P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Br, Rb and Sr) in plant samples. The quality of the results – in terms of accuracy, associated uncertainty and correlation between the two methods – was evaluated with regard to their usability for compositional classification of different rice genotypes with known tolerance levels to salinity stress. Plant uptake of essential elements was explored by Principal Component Analysis, which illuminated patterns between treatments (salt and control treatments) and across the rice genotypes tested.

  2. Direct Trace Element Analysis of Liquid Blood Samples by In-Air Ion Beam Analytical Techniques (PIXE-PIGE).

    Science.gov (United States)

    Huszank, Robert; Csedreki, László; Török, Zsófia

    2017-02-07

    There are various liquid materials whose elemental composition is of interest in various fields of science and technology. In many cases, sample preparation or the extraction can be complicated, or it would destroy the original environment before the analysis (for example, in the case of biological samples). However, multielement direct analysis of liquid samples can be realized by an external PIXE-PIGE measurement system. Particle-induced X-ray and gamma-ray emission spectroscopy (PIXE, PIGE) techniques were applied in external (in-air) microbeam configuration for the trace and main element determination of liquid samples. The direct analysis of standard solutions of several metal salts and human blood samples (whole blood, blood serum, blood plasma, and formed elements) was realized. From the blood samples, Na, P, S, Cl, K, Ca, Fe, Cu, Zn, and Br elemental concentrations were determined. The focused and scanned ion beam creates an opportunity to analyze very small volume samples (∼10 μL). As the sample matrix consists of light elements, the analysis is possible at ppm level. Using this external beam setup, it was found that it is possible to determine elemental composition of small-volume liquid samples routinely, while the liquid samples do not require any preparation processes, and thus, they can be analyzed directly. In the case of lower concentrations, the method is also suitable for the analysis (down to even ∼1 ppm level) but with less accuracy and longer measurement times.

  3. Results from the nuclear microprobe PIXE analysis of selected rare earth fluor compounds

    International Nuclear Information System (INIS)

    Hollerman, William A.; Gates, Earl; Boudreaux, Philip; Glass, Gary A.

    2002-01-01

    Most previous research measures fluorescence properties over the macroscopic regime. Properties of individual microscopic grains could be significantly different than those measured over the macroscopic scale. Until recently, it was difficult to measure properties of individual fluor grains. Existing characterization techniques like scanning electron microscopy are not practical, since the resulting fluorescence masks the electron surface profile. Starting in September 2000, a research program was initiated at the Acadiana Research Laboratory to determine microscopic fluorescence properties for selected inorganic rare earth compounds. The initial phase of this program utilized microscopic proton induced X-ray emission (μPIXE) to characterize the elemental composition of individual fluor grains. Results show that both individual grains and small clusters of grains could be seen using μPIXE. Maps of this type can be used to estimate grain dimensions for the selected rare earth fluor. This technique is a new and innovative method to characterize a fluor material

  4. Silver surface enrichment controlled by simultaneous RBS for reliable PIXE analysis of ancient coins

    International Nuclear Information System (INIS)

    Beck, L.; Alloin, E.; Berthier, C.; Reveillon, S.; Costa, V.

    2008-01-01

    Evidence of silver surface enrichment of ancient silver-copper coins has been pointed out in the past years. Surface enrichment can be fortuitous or intentional. In this paper, we have investigated the cleaning procedures usually performed after excavation or in museums. We have shown that chemicals or commercial products routinely used dissolve preferentially the copper phase and consequently contribute to the silver surface enrichment. As a result, surface analyses such as PIXE or XRF can be strongly affected by this effect. By using simultaneously RBS and PIXE, it is possible to check through the silver surface enrichment and then select the reliable measurements, characteristic of the bulk composition. Results on coins recently discovered and mechanically or chemically cleaned are presented

  5. Micro-PIXE analysis of fish otoliths. Methodology and evaluation of first results for stock discrimination

    International Nuclear Information System (INIS)

    Sie, S.H.; Thresher, R.E.

    1992-01-01

    Micro-PIXE has been used to measure the trace element distribution in otoliths from several species of ocean fish, in order to investigate its possible use in stock discrimination. Trace elements detected include Sr, Fe, Mn, Ni, Zn, Cu, Se, Cd, Br, Hg and Pb. Trace elements Na, K, Cl, S and Cl were detected with the electron microprobe. The high sensitivity of PIXE demands a meticulous sample preparation procedure to avoid contamination problems. Practical problems associated with the application of the technique were investigated in detail. Preliminary results indicate that most trace elements except Sr, are present at close to the limits of detection at few ppm, but biologically significant data can be obtained for stock discrimination applications. (author)

  6. Identification of elements in polutants of Mexico City's atmosphere, using the pixe analysis

    International Nuclear Information System (INIS)

    Diaz-Godoy, R.V.

    1990-01-01

    A review of the fundamentals and actual state in Mexico of the pixe (particle induced X- ray emission) technique are done. Elemental identification in samples of Mexico City's atmosphere taken in two sites is performed using this technique. A 3 MeV proton beam is used to irradiate the samples. Factors (Bremsstrahlung and interference) that difficult the use of the technique are discussed. The sensitivity of the method is enhanced as a main characteristic. It is shown that tje pixe technique together with an appropriate sampling system can be used to study environmental aerosols. Identified elements are bromine, lead, copper, iron, zinc, titanium, vanadium, calcium, potassium, chlorine, sulfur and silicon. Temporal variations of these elements are discussed. (Author)

  7. Analysis of HgI2 and PbI2 crystals and detectors by particle-induced x-ray emission (PIXE) and ion backscattering spectroscopy (IBS)

    International Nuclear Information System (INIS)

    Bench, G.S.; Heikkinen, D.W.; Antolak, A.J.; Morse, D.H.; Pontau, A.E.; James, R.B.; David, D.C.; Burger, A.; Van Den Berg, L.

    1993-03-01

    The Ion Micro-Analysis Group (IMAG) in Livermore conducts quantitative trace elemental analysis with PIXE and depth profiling with IBS using an MeV ion microbeam. The system has the capability to produce two-dimensional trace element and IBS images. PIXE analyses have been conducted on HgI 2 and PbI 2 crystals and detector materials in order to identify and quantify near surface trace contaminants. IBS measurements have been conducted to investigate elemental depth distributions in various materials. The results of measurements on several different samples are reported and a discussion of factors affecting quantitative in vacuo microanalysis of these materials is presented

  8. PIXE analysis of trace elements in relation to chlorophyll concentration in Plantago ovata Forsk

    International Nuclear Information System (INIS)

    Saha, Priyanka; Sen Raychaudhuri, Sarmistha; Chakraborty, Anindita; Sudarshan, Mathummal

    2010-01-01

    Plantago ovata Forsk - an economically important medicinal plant - was analyzed for trace elements and chlorophyll in a study of the effects of gamma radiation on physiological responses of the seedlings. Proton-induced X-ray emission (PIXE) technique was used to quantify trace elements in unirradiated and gamma-irradiated plants at the seedling stage. The experiments revealed radiation-induced changes in the trace element and chlorophyll concentrations.

  9. Nuclear techniques for trace element analysis. PIXE and its applications to biomedical samples

    International Nuclear Information System (INIS)

    Cata-Danil, I.; Moro, R.; Gialanella, G.

    1996-01-01

    Problems in understanding the role of trace elements in the functioning of life processes are discussed. A brief review of the state of the PIXE technique is given. Principles and recent advances in beam systems, instrumentation and sample handling are covered. A rather comprehensive list of references regarding varies methodological aspects and biomedical applications is given. Some applications are discussed. In particular, preliminary results of an investigation regarding pediatric obesity are presented. (author) 5 tabs., 21 refs

  10. Analysis of tree samples from an acidic and a limed environment by means of PIXE

    International Nuclear Information System (INIS)

    Pernestaal, K.; Li, Hong-Ko; Jonsson, B.; Haellgren, J.-E.

    1991-01-01

    Three tree core samples of Norway spruce (Picea Abies) have been analysed by PIXE. The concentration profiles for 17 elements heavier than sodium have been determined by means of one PIXE measurement every 2 mm along the samples. The samples were collected at Faexboda, an experimental area north of Uppsala where artificially acidified and limed environmental experiments are made. One sample from each of an acidified, a limed and a reference area has been collected. The main interest is focused on potassium, calcium, manganese, iron, copper and zinc. All three samples have about the same concentration profile in the heartwood. Large differences are observed in the sapwood. In the sample from the limed area the calcium content is much higher and the iron and chromium contents are lower than in the sample from the reference area. In the sample from the acidified area the calcium and potassium contents are lower and the manganese, iron and chromium contents are much higher than in the sample from the reference area. The observed concentration profiles of trace elements in trees indicate that changes in the environment due to acidification can be quantified at an early stage by means of PIXE. (author)

  11. The trace element analysis of ancient Indian coins using proton induced x-ray emission (PIXE) technique

    International Nuclear Information System (INIS)

    PURI, N.K.; HAJIVALIEI, M.; BEDI, S.C.; SINGH, N.; GOVIL, I.M.; GARG, M.L.; HANDA, D.K.; GOVIL, K.L.; ROUT, B.; VIJAYAN, V.

    2004-01-01

    Elemental analysis of ancient Indian coins viz. thirty-three punched marked coins (6 th century B.C.), fifty-nine coins belonging to Kusanas (78-250 A.D) and twenty-five coins belonging to medieval period (11 th -14 th century A.D), from India have been analysed using Proton Induced X-ray Emission (PIXE) technique. The elements namely S, Ca, Fe, Ag, Cu, Ni and Pb were detected in most of the punch-marked coins while elements namely S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, As and Zn were detected in most of the Kusanas coins and the S, Ca, Fe, Cu, Ag, Sn, Pb were detected in 11 th -14 th century A.D. coins. Based on the elemental analysis different hypotheses put forward in the earlier literature were examined. This is the first attempt where reasonable number of ancient coins belonging to different periods were analysed by modern non destructive multi-elemental technique such as PIXE and has put the importance of the elemental analysis of ancient Indian coins in the proper perspective

  12. Instrumentation for PIXE and RBS

    International Nuclear Information System (INIS)

    2000-12-01

    The purpose of this document is to give an overview of instrumentation for PIXE and Rutherford backscattering analysis, including hardware and software needed to perform the analysis, including detectors, analyzers, data acquisition systems and data analysis software. It also provides some information on accelerators needed for these applications

  13. PIXE and light element analysis (C,N) in glass inclusions trapped in meteorites with the nuclear microprobe

    International Nuclear Information System (INIS)

    Varela, M.E.; Mosbah, M.; Metrich, N.; Duraud, J.P.; Kurat, G.

    1999-01-01

    Proton-induced X-ray emission (PIXE) and light element analysis have been performed with the nuclear microprobe at the Laboratoire Pierre Suee (Saclay-France) in glass inclusions of the carbonaceous chondrites: Allende, Kaba and Renazzo, and in the achondrite meteorite: Chassigny. Carbon contents in olivine of chondrules are below the nuclear reactions analysis (NRA) detection limit, however, glasses from glass inclusions hosted by these grains, contain an appreciable and highly variable quantities of carbon (200-1600 ppm). This could indicate variable amounts of C trapped during glass inclusion formation. On the other hand, nitrogen is present in highly variable amounts in glasses of both, chondrites and achondrites minerals. Its abundance, correlated with depth from the section surface which suggests loss of N during analyses and therefore the possible existence of a very mobile (volatile?) species. A chondritic Rb/Sr and K/Rb ratio obtained by PIXE analyses in the glass-bearing inclusions of the Chassigny meteorite points towards a primitive source for the glass precursor of Chassigny inclusions

  14. Micro-PIXE analysis of varied sulfide populations from the Ventersdorp Contact Reef, Witwatersrand Basin, South Africa

    Science.gov (United States)

    Reimold, W. U.; Przybylowicz, W.; Koeberl, C.

    1999-10-01

    Micro-PIXE spot analysis and true elemental imaging of pyrrhotite and pyrite crystals from the Ventersdorp Contact Reef (VCR) of the Witwatersrand basin, the world's most important gold resource, are reported. The objective was to evaluate the use of this technique with regard to its analytical resolution concerning the detection limits for the elements encountered in these samples and their spatial distribution. Furthermore, this project was designed to identify chemical signatures characteristic for particular textural types of VCR sulfides. Micro-PIXE is indeed a highly useful technique for the analysis of such materials and provided results that could not be obtained by optical and SEM microscopy and electron probe microanalysis (EPMA). Micro-inclusions could be made visible through elemental area scanning. Chemical zonation in the interior of apparently homogeneous grains was detected, which has obvious implications for the interpretation of the multi-stage evolution of Witwatersrand mineralization. The available data do not yet allow unambiguous chemical classification of different sulfide types (generations), but a distinct late growth of As-enriched sulfide was detected. These late overgrowths may be enriched in Ni or not. No unambiguous relation between As and Au could be observed in these samples.

  15. Trace metal analysis in sea grasses from Mexican Caribbean Coast by particle induced X-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Solis, C.; Issac O, K.; Martinez, A.; Lavoisier, E.; Martinez, M. A.

    2008-01-01

    The growing urban and tourist activity in the Mexican Caribbean coasts has resulted in an increase of chemical substances, metals in particular, discharged to the coastal waters. In order to reach an adequate management and conservation of these marine ecosystems it is necessary to perform an inventory of the actual conditions that reflect the vulnerability and the level of damage. Sea-grasses are considered good biological indicators of heavy metal contamination in marine systems. The goal of this preliminary work is to evaluate the concentrations of trace metals such as Cr, Mn, Fe, Co, Cu, Zn, and Pb in Thalassia testudinum, a very common sea-grass in the Mexican Caribbean Sea. Samples were collected from several locations in the coasts of the Yucatan Peninsula: Holbox, Blanquizal and Punta Allen, areas virtually uninfluenced by anthropogenic activities. Trace elements in different part plants were determined by particle induced X-ray emission (PIXE). This is a very suitable technique since it offers a fast, accurate and multi-element analysis. Also, the analysis by PIXE can be performed directly on powdered leaves without a laborious sample preparation. The trace metal concentration determined in sea-grasses growing in Caribbean generally fall in the range of the lowest valuables reported for sea grasses from the Gulf of Mexico. The results indicate that the studied areas do not present contamination by heavy metals. (Author)

  16. Internal/external mixing of aerosol particles elemental composition retrieved from microPIXE and PIXE

    International Nuclear Information System (INIS)

    Ghermandi, G.; Cecchi, R.; Lusvarghi, L.; Laj, P.; Zappoli, S.; Ceccato, D.

    2005-01-01

    A statistical evaluation of the association between different elements contained in atmospheric aerosol particles has been made using the microPIXE technique. We derived elemental maps of Al, Si, S, Ca, Cl, K, Fe, Mg spatial distribution on the surface of a Nuclepore filter sample. The microPIXE measurements are validated by comparison to conventional PIXE and SEM-EDAX. Then, the spatial coherence of the different elements is analysed using statistical methods. The elements are not homogeneously distributed and the association among specific elements can be identified. MicroPIXE and factorial analysis can be coupled to understand the state of mixing of the different elements on the filter surface

  17. PIXE analysis of sand and soil from Ulaanbaatar and Karakurum, Mongolia

    Science.gov (United States)

    Markwitz, A.; Barry, B.; Shagjjamba, D.

    2008-09-01

    Twenty-one sand and soil samples were collected at the surface from 22 to 25 June 2007 at sampling sites from Ulaanbaatar to Karakurum, Mongolia. The sand samples were collected from constantly changing sand dunes which may still contain salt from prehistoric oceans. The dry sand and soil samples were processed for PIXE and PIGE analyses. A clear division between soils and sand become apparent in the silicon results. Concentrations of all bulk elements in human habitation samples and of Si, Al, K and Fe in dry lake/flood plain samples are similar to those in the soils and sands. Among elements which could be regarded as being at trace concentrations the average S concentration in the soils is 0.9 g kg-1 whereas it is not detected in the sand samples. Zinc and Cu concentrations are both higher in the soils than the sands and are strongly correlated. A surprising presence of uranium at a concentration of 350 mg kg-1 was detected in the PIXE measurement on one of the dry lake samples. Gamma spectrometry confirmed the presence of U in this sample and also at a lower level in a sample from the lake shore, but in none of the other samples. Further, the gamma spectrometry showed that 238U decay products were present only at a level corresponding to about 3 mg kg-1 U for a system in radioactive equilibrium, a figure which is typical for U in the earth's crust. Disequilibria between 238U and its decay products occur naturally but such a high degree of separation at high concentration would be unique if confirmed. PIXE and PIGE measurements of these samples highlight the difficulty in correlating trace element measurements with occurrence of indicators of sea salt in air particulate samples.

  18. PIXE studies on teeth

    International Nuclear Information System (INIS)

    Chaudhri, M.A.; Ainsworth, T.

    1980-01-01

    The elemental composition of healthy and diseased teeth from 25 children has been determined using thick-target proton induced x-ray emission, (PIXE), analysis. Various dental hard tissues: enamel, dentine and cementum, and their junctions, as well as different parts of the same tissue, have been examined individually. A number of elements: Na, Mg, Al, P, S, Cl, Ca, V, Cr, Mn, Fe, Ni, Cu, Zn, Sr and Pb, has been determined in these dental tissues. The concentrations of some of the elements tend to vary considerably from tooth to tooth and tissue to tissue. Attempts have been made to correlate the concentrations of various elements in teeth with their health

  19. Elemental analysis of ancient Chinese bronze artifacts with external-beam PIXE

    International Nuclear Information System (INIS)

    Lin, E.K.; Yu, Y.C.; Wang, C.W.; Shen, C.T.; Huang, Y.M.; Wu, S.C.; Hsieh, C.H.

    1992-01-01

    External-beam PIXE has been applied for the determination of the elemental composition of ancient Chinese bronze artifacts. Characteristic x-ray spectra from the samples bombarded with protons of 3 MeV have been measured with a HPGe detector. At each sample three spots were irradiated per run. Results of measurements on three fragments of bronze drinking vessels and helmet of Chinese ancient Chou and Shang dynasties (17th-8th century B.C.) are presented. To check the analytical method, we have also made measurements on the elemental composition of some modern coins. The results are discussed. (author)

  20. PIXE analysis of remaining bromine in fumigated old manuscripts and books

    International Nuclear Information System (INIS)

    Kohno, M.; Yoshida, K.; Moritani, K.; Naito, M.; Enami, K.; Kasajima, H.; Takada, J.; Matsushita, R.

    1999-01-01

    Buddhist scriptures in Reeky University Library have been fumigated regularly for protecting them from vermin. Methyl bromide (CH 3 Br) had been used there till 1985. In order to examine whether the chemical remains on the fumigated objects or not, paper fragments of old manuscripts and books, modern paper placed together with them, and non-fumigated ones were analyzed by PIXE. The bromine concentration of fumigated paper was more than from several tens to several hundreds times higher than non-fumigated ones. (author)

  1. Trace element analysis of mineral water samples by PIXE and ICP-MS

    International Nuclear Information System (INIS)

    Kennedy, V.John; Augusthy, A.; Varier, K. M.; Magudapathy, P.; Panchapakesan, S.; Nair, K.G.M.

    1998-01-01

    Trace elements present in bottled mineral water have been studied by PIXE and ICP-MS. Samples from ten different brands of brands of bottled mineral water were prepared by preconcentration techniques. Measurements were carried out using the 2 MeV proton beam obtained from 3 MV Tandem pelletron accelerator at the Institute of Physics, Bhubaneswar. Our results are compared with Indian standard packaged natural mineral water specifications, World Health Organisation (WHO) and European guidelines for drinking water standards. Concentration of aluminum was found to be more in one of the brands. In general, our results are comparable to the above standards. (author)

  2. The validation of a pixe system for trace element analysis of biological samples

    Science.gov (United States)

    Saied, S. O.; Crumpton, D.; Francois, P. E.

    1981-03-01

    A PIXE system has been developed for measuring trace element levels in biological samples and a study made of the precision and accuracy achievable. The calibration of the system has been established using thin targets of known elemental composition and the reproducibility studied using protons of energy 2.5 MeV. Both thick and thin samples prepared from NBS bovine liver have been analysed and the elemental ratios present established for a set of replicate samples. These are compared with the results of other workers. Problems relating to sample preparation are discussed.

  3. Elemental analysis of ancient Chinese bronze artifacts with external-beam PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Lin, E.K.; Yu, Y.C.; Wang, C.W.; Shen, C.T.; Huang, Y.M.; Wu, S.C.; Hsieh, C.H. [Academia Sinica, Taipei, TW (China). Inst. of Physics

    1992-12-31

    External-beam PIXE has been applied for the determination of the elemental composition of ancient Chinese bronze artifacts. Characteristic x-ray spectra from the samples bombarded with protons of 3 MeV have been measured with a HPGe detector. At each sample three spots were irradiated per run. Results of measurements on three fragments of bronze drinking vessels and helmet of Chinese ancient Chou and Shang dynasties (17th-8th century B.C.) are presented. To check the analytical method, we have also made measurements on the elemental composition of some modern coins. The results are discussed. (author).

  4. Enhanced X-ray yields in PIXE analysis of some binary metal fluorides

    International Nuclear Information System (INIS)

    Peisach, M.; Pineda, C.A.; Pillay, A.E.

    1993-01-01

    Enhanced X-ray yields from the metal components of homogeneous thick targets of binary metal fluorides were observed during PIXE irradiations with protons, deuterons and 3 He ions. The absence of these effects in the pure metals and in the corresponding metal oxides, nitrides and borides suggests that the fluoride component in such compounds plays a key role in producing the enhancement. Coulomb excitation of the extremely low-lying levels of the fluorine nucleus is discussed as a possible mechanism for the improved yields via secondary excitation. (orig.)

  5. A comparison of fossilized dinosaur bone and the surrounding rock using PIXE analysis

    International Nuclear Information System (INIS)

    Neilsen, D.W.; Rees, L.B.; Mangelson, N.F.; Hill, M.W.

    1992-01-01

    Six samples of fossilized dinosaur bone and surrounding rock were analyzed by PIXE to investigate general relations between the bone and rock. The powdered samples were brought into an acid solution by a lithium metaborate fusion process. The data were analyzed with chemometric methods to successfully differentiate the bone samples from the complementary rock samples. The Sr/Ca ratio is consistently higher in fossilized bone than the surrounding rock. Ba, Y and U, when found in the rock, appear in significantly higher concentrations in the bone. S and Ti, elements commonly found in rock samples, are not found in the bone samples. (author)

  6. PIXE analysis of U and Pu from hot particles: K-lines vs L-lines

    DEFF Research Database (Denmark)

    Jiménez-Ramos, M.C.; García López, J.; Eriksson, M.

    2012-01-01

    . (2007) [1] and Jiménez-Ramos et al. (2010) [2], radioactive particles from aircraft accidents in Palomares and Thule have been characterized. Using micro-Proton Induced X-ray Emission (μ-PIXE) and confocal X-ray fluorescence microprobe (μ-XRF), the L-lines of the main components in these particles, U......-lines present not overlapping between the main peaks in the spectra and the X-ray absorption in the sample is much lower than for L-lines....

  7. PIXE analysis of atmospheric aerosols in the city of Buenos Aires

    International Nuclear Information System (INIS)

    Ozafran, M.J.; Vazquez, M.E.; Burlon, A.

    1999-01-01

    Lead pollution present in atmospheric aerosols in the city Buenos Aires was measured in 1989, using Heavy Ion PIXE. Since then, environmental conditions have changed significantly. The usage of unleaded gasoline was introduced, and the utilisation of compressed natural gas as car fuel has increased. Recently, a new sampling campaign of atmospheric aerosols has started, partly in collaboration with the Greenpeace Foundation. The present studies reveal that lead pollution in Buenos Aires has significantly decreased since 1989. The concentrations of other elements are determined as well. (author)

  8. Application of PIXE analysis to environmental samples stable element distribution in sea algae by scanning microprobe analysis

    International Nuclear Information System (INIS)

    Ishikawa, M.; Kitao, K.; Imaseki, H.; Ishii, T.; Uchida, S.

    1984-01-01

    The resolution of a 33+-3 μm microprobe focussed with quadrupole doublet installed at the 3 MV Van de Graaff of the National Institute of Radiological Sciences, Japan, was used for the present analysis. Brown algae, Hizikia fusiforme was the sample target bombarded with a 2 MeV proton beam collimated mechanically into a rectangular image of 100 μm x 700 μm. Scanning across the sample target prepared into a longitudinal section from the caulis of the algae provided the following observations. More than 12 elements such as Al, Si, P, Cl, Ca, Mn, Fe, Cu, Zn, As, Br and Sr were determined simultaneously, together with their distributional information across the diameter. In the medullary layer, Mn and Zn were specific in their accumulation, while the deposition of Fe, Cu, As and Br were observed to be high in the epithelial layer, especially Fe and Cu which were found on the surface, where they contacted ambient sea water, but no significant change in pattern was indicated for such elements as Al, P and Cl. The PIXE microprobe analysis was, therefore, effective in its detectability for elements below a few ppm level, resultantly providing further possibilities for collecting information from bio-medical and environmental samples on trace characterization of elements. (author)

  9. Analysis and simulation of an electrostatic FN Tandem accelerator

    International Nuclear Information System (INIS)

    Ugarte, Ricardo

    2007-01-01

    An analysis, modeling, and simulation of a positive ion FN Tandem electrostatic accelerator has been done. That has induced a detailed study over all physics components inside the accelerators tank, the terminal control stabilizer (TPS), the corona point, the capacitor pick off (CPO) and over the generating voltmeter (GVM) signals. The parameter of the model has been developed using the Prediction Error estimation Methods (PEM), and within classical techniques of analysis of circuits. The result obtained was used to check and increase the stability of the terminal voltage using Matlab software tools. The result of the simulation was contrasted with the reality and it was possible to improve the stability of the terminal voltage, successfully. The facility belongs to ARN (Argentina) and, in principle, it was installed to development an AMS system. (author)

  10. Fluorine analysis of human dentin surrounding resin composite after fluoride application by μ-PIGE/PIXE analysis

    International Nuclear Information System (INIS)

    Okuyama, Katsushi; Komatsu, Hisanori; Yamamoto, Hiroko; Pereira, Patricia N.R.; Bedran-Russo, Ana K.; Nomachi, Masaharu; Sato, Takahiro; Sano, Hidehiko

    2011-01-01

    The use of fluoride for the prevention of caries is based on the transformation of hydroxylapatite to fluoroapatite in the presence of fluoride ions, thereby strengthening tooth structure. Adhesion of dentin and resin composite (tooth-colored restoration material) requires a dentin bonding system, since resin composite is not able to adhere to dentin directly. Demineralization of dentin by acid etching is an important step in the dentin bonding system, however, demineralization also introduces weaknesses in tooth structure. If the demineralized dentin could be strengthened by the application of fluoride, then the dentin-resin composite bond strength might also improve. To test this hypothesis, the present study evaluated the influence of fluoride applications on the strength of the dentin-resin composite bond by (1) tensile strength testing analyses, (2) SEM analyses of tooth structure, and (3) detection of calcium (Ca) and fluorine (F) distribution patterns by micro proton-induced X-ray emission (μ-PIXE) and micro proton-induced gamma-ray emission (μ-PIGE) analyses conducted at the Takasaki Ion Accelerators for Advanced Radiation Application (TIARA) at the Takasaki Advanced Radiation Research Institute (TARRI). In this study, the dentin in extracted human molars was exposed by grinding and the dentin was etched with 35% phosphoric acid. Fluoride was applied at two concentrations, 0.022% (100 ppm F) and 2.21% (10,000 ppm F) NaF solution, for two time periods, 30 and 60 s, prior to bonding the resin composite with the treated dentin. Controls were prepared in the same manner, but without the fluoride application. Bond strength was measured with a micro-tensile testing unit, and the fluorine and calcium distributions at the interface between dentin and resin composite were detected by μ-PIGE and μ-PIXE analysis, respectively. Results indicate that the 10,000 ppm F applications resulted in higher bond strengths than observed in either the 100 ppm F applications or

  11. Fluorine analysis of human dentin surrounding resin composite after fluoride application by μ-PIGE/PIXE analysis

    Science.gov (United States)

    Okuyama, Katsushi; Komatsu, Hisanori; Yamamoto, Hiroko; Pereira, Patricia N. R.; Bedran-Russo, Ana K.; Nomachi, Masaharu; Sato, Takahiro; Sano, Hidehiko

    2011-10-01

    The use of fluoride for the prevention of caries is based on the transformation of hydroxylapatite to fluoroapatite in the presence of fluoride ions, thereby strengthening tooth structure. Adhesion of dentin and resin composite (tooth-colored restoration material) requires a dentin bonding system, since resin composite is not able to adhere to dentin directly. Demineralization of dentin by acid etching is an important step in the dentin bonding system, however, demineralization also introduces weaknesses in tooth structure. If the demineralized dentin could be strengthened by the application of fluoride, then the dentin-resin composite bond strength might also improve. To test this hypothesis, the present study evaluated the influence of fluoride applications on the strength of the dentin-resin composite bond by (1) tensile strength testing analyses, (2) SEM analyses of tooth structure, and (3) detection of calcium (Ca) and fluorine (F) distribution patterns by micro proton-induced X-ray emission (μ-PIXE) and micro proton-induced gamma-ray emission (μ-PIGE) analyses conducted at the Takasaki Ion Accelerators for Advanced Radiation Application (TIARA) at the Takasaki Advanced Radiation Research Institute (TARRI). In this study, the dentin in extracted human molars was exposed by grinding and the dentin was etched with 35% phosphoric acid. Fluoride was applied at two concentrations, 0.022% (100 ppm F) and 2.21% (10,000 ppm F) NaF solution, for two time periods, 30 and 60 s, prior to bonding the resin composite with the treated dentin. Controls were prepared in the same manner, but without the fluoride application. Bond strength was measured with a micro-tensile testing unit, and the fluorine and calcium distributions at the interface between dentin and resin composite were detected by μ-PIGE and μ-PIXE analysis, respectively. Results indicate that the 10,000 ppm F applications resulted in higher bond strengths than observed in either the 100 ppm F applications or

  12. Fluorine analysis of human dentin surrounding resin composite after fluoride application by {mu}-PIGE/PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, Katsushi, E-mail: katsu@den.hokudai.ac.jp [Graduate School of Dental Medicine, Hokkaido University, Department of Restorative Dentistry, Kita-13, Nishi-7, Kita-ku, Hokkaido, Sapporo 060-8586 (Japan) and School of Dentistry, University of North Carolina, Department of Operative Dentistry, 302 Brauer, CB 7450, Chapel Hill, NC 27599-7450 (United States); Komatsu, Hisanori [Graduate School of Dental Medicine, Hokkaido University, Department of Restorative Dentistry, Kita-13, Nishi-7, Kita-ku, Hokkaido, Sapporo 060-8586 (Japan); Yamamoto, Hiroko [Graduate School of Dentistry, Osaka University, 1-8 Yamada-Oka, Osaka, Suita 565-0871 (Japan); Pereira, Patricia N.R. [School of Dentistry, University of North Carolina, Department of Operative Dentistry, 302 Brauer, CB 7450, Chapel Hill, NC 27599-7450 (United States); Bedran-Russo, Ana K. [University of Illinois at Chicago, College of Dentistry, Department of Restorative Dentistry, 801 S. Paulina St., Chicago, IL 60612 (United States); Nomachi, Masaharu [Graduate School of Science, Osaka University, 1-1 Machikaneyama, Osaka, Toyonaka 560-0043 (Japan); Sato, Takahiro [TARRI, JAEA, Advanced Radiation Technology, 1233 Watanuki-machi, Gunma, Takasaki 370-1292 (Japan); Sano, Hidehiko [Graduate School of Dental Medicine, Hokkaido University, Department of Restorative Dentistry, Kita-13, Nishi-7, Kita-ku, Hokkaido, Sapporo 060-8586 (Japan)

    2011-10-15

    The use of fluoride for the prevention of caries is based on the transformation of hydroxylapatite to fluoroapatite in the presence of fluoride ions, thereby strengthening tooth structure. Adhesion of dentin and resin composite (tooth-colored restoration material) requires a dentin bonding system, since resin composite is not able to adhere to dentin directly. Demineralization of dentin by acid etching is an important step in the dentin bonding system, however, demineralization also introduces weaknesses in tooth structure. If the demineralized dentin could be strengthened by the application of fluoride, then the dentin-resin composite bond strength might also improve. To test this hypothesis, the present study evaluated the influence of fluoride applications on the strength of the dentin-resin composite bond by (1) tensile strength testing analyses, (2) SEM analyses of tooth structure, and (3) detection of calcium (Ca) and fluorine (F) distribution patterns by micro proton-induced X-ray emission ({mu}-PIXE) and micro proton-induced gamma-ray emission ({mu}-PIGE) analyses conducted at the Takasaki Ion Accelerators for Advanced Radiation Application (TIARA) at the Takasaki Advanced Radiation Research Institute (TARRI). In this study, the dentin in extracted human molars was exposed by grinding and the dentin was etched with 35% phosphoric acid. Fluoride was applied at two concentrations, 0.022% (100 ppm F) and 2.21% (10,000 ppm F) NaF solution, for two time periods, 30 and 60 s, prior to bonding the resin composite with the treated dentin. Controls were prepared in the same manner, but without the fluoride application. Bond strength was measured with a micro-tensile testing unit, and the fluorine and calcium distributions at the interface between dentin and resin composite were detected by {mu}-PIGE and {mu}-PIXE analysis, respectively. Results indicate that the 10,000 ppm F applications resulted in higher bond strengths than observed in either the 100 ppm F

  13. PIXE analysis of museum soapstone sculptures from Esie, south west Nigeria

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Olarewaju, V.O.; Onabajo, O.

    1989-05-01

    The PIXE technique was employed for the study of Esie museum stone sculptures using 2.55 MeV protons from the 3 MeV tandem accelerator (NEC 3 UDH) in Lund, coupled with the geological and archaeological findings. The aim is to elucidate and decipher the prodigious but rather enigmatic and bewildering stone sculptures. PIXE results show that the composition of the stone sculptures are 40.69% talc-tremolite schist, 30.88% talc-chlorite schist, 15.20% talc-tremolite-anthophyllite schist and 13.24% talc-amphibolite schist. Thus the composition of Esie sculptures are found to be the same with the locally available talc-schists present around Esie. The geological evidence (mineralogical results) corroborated this as there was no textural or mineralogical difference between the talc-bearing country rock (outcrop) in Esie and the museum soapstone samples studied. Consequently, there is a very high probability that the sculptures were carved using the locally available talc-schists. (author). 7 refs, 4 figs, 2 tabs

  14. Characterization of regional atmospheric aerosols over Hungary by PIXE elemental analysis

    International Nuclear Information System (INIS)

    Koltay, E.; Szabo, G.; Borbely Kiss, I.; Somorjai, E.; Kiss, A.Z.

    1994-01-01

    Studying the characteristic features of atmospheric aerosols emitted by natural and anthropogenic sources is of basic importance for a detailed understanding of the physics and chemistry of the atmosphere. Environmental pollution by atmospheric aerosols and their impact can be tested in the same way, too. The separation of natural and anthropogenic components of the aerosol can be done through enrichment factors and size distribution curves deduced from analytical information. The Particle Induced X-ray Emission (PIXE) technique has been applied in aerosol studies by the authors. Results obtained on atmospheric aerosols collected over Hungary and presented in terms of concentrations, enrichment factors, regional signatures, deposition velocities, transport properties and apportionment of sources illustrate the scope and proportions of the potential contribution of PIXE to the methodology of atmospheric aerosol studies. Continued activity planned in the framework of the present CRP may widen the scope of the investigations mainly in the field of size-fractioned sampling and - possibly - in the direction of individual characterization of aerosol particles. (author). 14 refs

  15. Trace element analysis of the Otani Collection's Dunhuang and Turfan manuscripts by PIXE

    International Nuclear Information System (INIS)

    Kohno, M.; Yoshida, K.; Moritani, K.; Norizawa, K.; Enami, K.; Kasajima, H.; Ueyama, D.; Takada, J.; Matsushita, R.

    1999-01-01

    In order to classify the Otani Collection's Dunhuang and Turfan manuscripts, their trace elements were analyzed by PIXE. The paper samples of these manuscripts were fallen off when they were photographed for a CD-ROM catalog. These samples were very small and their size was less than several millimeters. In addition, some paper fragments dating from the late Edo-era of Japan and the late Qing Dynasty of China, and modern Japanese handmade paper were analyzed using PIXE and NAA. Quite interesting results were obtained when analyzing the trace elements - Na, Mg, Al, Si, S, Cl, K, Ca, Sc, Mn, Fe, Cu, Zn, As, Br, Sr, Ba, Pb, La, Sm. It was found that Dunhuang and Turfan papers of the Otani Collection were characterized by its highest iron and bromine content. The reason of the highest iron content probably originates in their making process and/or depends on their preservative environment. On the other hand, it became clear as for the highest bromine content that the origin is from fumigation of methyl bromide. (author)

  16. Study of new sheep bone and Zn/Ca ratio around TiAlV screw: PIXE RBS analysis

    Science.gov (United States)

    Guibert, G.; Munnik, F.; Langhoff, J. D.; Von Rechenberg, B.; Buffat, Ph. A.; Laub, D.; Faber, L.; Ducret, F.; Gerber, I.; Mikhailov, S.

    2008-03-01

    This study reports on in vivo particle induced X-ray emission (PIXE) measurements combined with Rutherford backscattering spectroscopy (RBS) analyses of new remodeled sheep bone formed around TiAlV screws. The implants (screws) were anodized by a modified TiMax™ process. The interface between the implant and the bone was carefully investigated. [Zn]/[Ca] in-depth composition profiles as well as Ca, Fe elemental maps were recorded. The thickness of new bone formed around the screw reached 300-400 μm. Osteon and Osteoid phases were identified in the new bone. A higher [Zn]/[Ca] ratio was observed in the new bone as compared to the mature bone. Blood vessels were observed in the bone in close contact with the screw. This study shows the potential of ion beam analysis for biological and biomedical characterization.

  17. Study of new sheep bone and Zn/Ca ratio around TiAlV screw: PIXE-RBS analysis

    International Nuclear Information System (INIS)

    Guibert, G.; Munnik, F.; Langhoff, J.D.; Von Rechenberg, B.; Buffat, Ph.A.; Laub, D.; Faber, L.; Ducret, F.; Gerber, I.; Mikhailov, S.

    2008-01-01

    This study reports on in vivo particle induced X-ray emission (PIXE) measurements combined with Rutherford backscattering spectroscopy (RBS) analyses of new remodeled sheep bone formed around TiAlV screws. The implants (screws) were anodized by a modified TiMax TM process. The interface between the implant and the bone was carefully investigated. [Zn]/[Ca] in-depth composition profiles as well as Ca, Fe elemental maps were recorded. The thickness of new bone formed around the screw reached 300-400 μm. Osteon and Osteoid phases were identified in the new bone. A higher [Zn]/[Ca] ratio was observed in the new bone as compared to the mature bone. Blood vessels were observed in the bone in close contact with the screw. This study shows the potential of ion beam analysis for biological and biomedical characterization

  18. Trace element analysis with PIXE using Trombay 5.5 MeV Van de Graaff accelerator

    International Nuclear Information System (INIS)

    Govil, Rekha; Kataria, S.K.; Kapoor, S.S.; Madan Lal; Nadkarni, D.M.; Rama Rao, P.N.; Viswanathan, K.V.

    1980-01-01

    The work on trace element analysis using proton induced X-ray emission technique (PIXE) with the proton beam from 5.5 MeV Van de Graaff accelerator at Trombay, is described. The experimental set up consisted of an indigeneously built 220 eV resolution Si(Li) x-ray spectrometer and target chamber having arrangements to mount upto twelve targets. In the present work, a variety of samples of biological nature, monazite mineral and some other samples were analyzed along with a standard multi-element sample. The sample preparation technique for different samples is also given in the report. For quantitative estimation of trace elements, a computer code developed earlier was used. The proton induced x-ray spectra of various samples and their computer fits are presented and quantitative results for some selected samples are also given. The minimum detection limits which were achieved with the present set up are also given. (auth.)

  19. Determination of several trace metals in biological materials by PIXE analysis after solvent extraction and polystyrene-film collection

    International Nuclear Information System (INIS)

    Iwata, Yoshihiro; Korenaga, Tatsumi; Suzuki, Nobuo

    1991-01-01

    Traces of vanadium, manganese, iron, cobalt, nickel, copper, and zinc were quantitatively extracted with diethyldithiocarbamate (DDTC) in benzene from a digested solution of biological materials and the metal-DDTC complexes were collected into a small amount of polystyrene foam produced by lyophilization of the benzene extract after addition of polystyrene. The polystyrene foam was dissolved in benzene and spread on Mylar film. After drying, a polystyrene film containing metal-DDTC complexes was produced on Mylar film, and then the polystyrene film was peeled from the Mylar film. This film was subjected to PIXE analysis. This method was applied to NBS SRM 1572 citrus leaves and a marine macroalgal sample, and 6 trace metals were simultaneously and accurately determined. (author)

  20. Development of a PIXE (Particle Induced X-ray Emission) analysis device using an extracted proton beam

    International Nuclear Information System (INIS)

    Saidi, A.

    1989-01-01

    The experimental device described allows the extention of the PIXE (Particle Induced X-ray Emission) method to the analysis, by means of proton beams, of solid or liquid samples, which can not be analyzed under vacuum conditions. The homogeneity of the surfaces to be analysed and elements (in the atmosphere) which absorb X-rays must be taken into account. Liquid samples do not need special care. The results show that: at high energies, the extracted beam sensibility is of the same order of magnitude as those obtained under vacuum; at low energies, the performance under vacuum conditions is better. The particles energy losses, at the exit membrane and in the outer atmosphere, decrease the X-rays production efficiency [fr

  1. PIXE analysis of proto-porcelain excavated from the Huoshaoshan kiln site in Deqing County, Zhejiang Province

    International Nuclear Information System (INIS)

    Zhang Bin; Cheng Huansheng; Zheng Jianming

    2014-01-01

    Background: Zhejiang Province is an important producing area of proto-porcelain. Huoshaoshan kiln site in Deqing County is the only kiln known currently for firing proto-porcelain from the late Western Zhou Dynasty to the late Spring and Autumn Period. Also it is the earliest kiln site unearthed for only firing proto-porcelain so far. It is of great significance for the exploration of Chinese early celadon firing technology. Purpose: The aim is to disclose the elemental characteristics of these proto-porcelains and study the sources of the raw materials and relationship between these proto-porcelains. Methods: We selected 18 samples made at the early period (from the late Western Zhou Dynasty to the early Spring and Autumn Period), 15 samples made at the middle and last period (the last period of the middle Spring and Autumn Period), and 17 samples made at the last period (the last period of the late Spring and Autumn Period). Proton Induced X-ray Emission (PIXE) was used to analyze these samples and measure the chemical compositions of these proto-porcelains. The factor analysis is used to study the sources of the raw materials and relationship between these proto-porcelains made in the different periods. Results: The results show that for the raw materials of body and glaze, the proto-porcelains at the last period are different from those at the early period, while the same as those at the middle and last period. Conclusion: PIXE combining with factor analysis can be used to study effectively the sources of the raw materials and relationship between these proto-porcelains. (authors)

  2. PIXE analysis of hilar gland for the evaluation of personal history of exposure to environmental contaminants

    International Nuclear Information System (INIS)

    Adachi, Shuichi; Takemoto, Kazuo; Sasa, Yoshihiko; Maeda, Kunihiko.

    1992-01-01

    Seven autopsied cases were studied for the evaluation of individual history of exposure to environmental contaminants based on the elemental profile of hilar gland by PIXE and lung tissue by AAS. The results well characterized their occupational history, especially from Cr, Al, Si and As detection. Moreover, it might be possible that these analyses would provide data to suspect the chemical form of each element in deposited particles of lung parenchyma, since the solubility could reflect the different profile of element between hilar gland and lung parenchyma. In addition to these retrospective analyses using the materials obtained from autopsies, it is possible to assess the individual risk using small quantity of hilar gland or lung tissue obtained by biopsy or surgical resection. (author)

  3. Compositional studies on Transylvanian gold nuggets: Advantages and limitations of PIXE-PIGE analysis

    International Nuclear Information System (INIS)

    Bugoi, Roxana; Cojocaru, Viorel; Constantinescu, Bogdan; Calligaro, Thomas; Pichon, Laurent; Roehrs, Stefan; Salomon, Joseph

    2008-01-01

    Minute fragments from nine gold nuggets from Transylvania - two belonging to placer deposits and seven to primary deposits - were analyzed by PIXE and PIGE at the AGLAE tandem accelerator of the Centre de Recherche et de Restauration des Musees de France (C2RMF) with a 3 MeV proton beam extracted into air. This study was triggered by some archaeological provenance issues for which the elemental characterization of the Transylvanian gold source, exploited from the Antiquity, was required. All analyzed Transylvanian gold nuggets are characterized by a consistently high amount of Ag (18% on average). Au and Ag add up to roughly 99%, the other elements - Cu, Fe, Te, Pb - being detected only at a trace level. The obtained results are in good agreement with the previous analyses of Transylvanian gold

  4. PIXE and ICP-MS Analysis of Andrographis Paniculata Medicinal Plant

    Science.gov (United States)

    Chandrasekhar Rao, J.; Naidu, B. G.; Sarita, P.; Srikanth, S.; Naga Raju, G. J.

    2017-08-01

    The concentrations of elements Li, Be, Al, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Br, Rb, Sr, Ag, Cd, Ba, Pb and U in Andrographis Paniculata medicinal plant used in the treatment of Diabetes Mellitus were determined by using Particle Induced X-ray Emission (PIXE) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) techniques. This plant was collected from four different geographical locations in Andhra Pradesh, India in order to assess the regional variation of elemental concentrations. Appreciable levels of K, Ca, Cr, Mn, Cu and Zn determined in this plant can be correlated to the antidiabetic property of Andrographis Paniculata since these elements are known to regulate and potentiate insulin action. Presence of toxic elements As, Cd and Pb necessitates the adoption of precautionary measures while prescribing dosage of the herbal medicine prepared from this plant for the treatment diabetes mellitus.

  5. PIXE analysis of tumors and localization behavior of a lanthanide in nude mice

    Science.gov (United States)

    Chang, Pei-Jiun; Yang, Czau-Siung; Chou, Ming-Ji; Wei, Chau-Chin; Hsu, Chu-Chung; Wang, Chia-Yu

    1984-04-01

    We have used particle induced X-ray emission (PIXE) to analyze the elemental compositions and uptakes of a lanthanide, yttrium in this report, in tumors and normal tissues of nude mice. A small amount of yttrium nitrate was injected into nude mice with tumors. Samples of normal and malignant tissues taken from these mice were bombarded by the 2 MeV proton beam from a 3 MeV Van de Graaff accelerator with a Ge detector system to determine the relative elemental compositions of tissues and the relative concentrations of yttrium taken up by these tissues. We found that the uptakes of yttrium by tumors were at least five times more than those by normal tissues. Substantial differences were often observed between the trace element weight (or concentration) pattern of the cancerous and normal tissues. The present result is compared with human tissues.

  6. Heavy metal distribution in Suillus luteus mycorrhizas - as revealed by micro-PIXE analysis

    Science.gov (United States)

    Turnau, K.; Przybyłowicz, W. J.; Mesjasz-Przybyłowicz, J.

    2001-07-01

    Suillus luteus/Pinus sylvestris mycorrhizas, collected from zinc wastes in Southern Poland, were selected as potential biofilters on the basis of earlier studies carried out with energy dispersive spectrometry (EDS) microanalytical system coupled to scanning electron microscope (SEM) and transmission electron microscope (TEM). Using the National Accelerator Centre (NAC) nuclear microprobe, elemental concentrations in the ectomycorrhiza parts were for the first time estimated quantitatively. Micro-proton-induced X-ray emission (PIXE) true elemental maps from freeze-dried and chemically fixed mycorrhizas revealed strong accumulation of Ca, Fe, Zn and Pb within the fungal mantle and in the rhizomorph. Vascular tissue was enriched with P, S and K, while high concentrations of Si and Cl were present in the endodermis. Cu was the only element showing elevated concentrations in the cortex region. Elemental losses and redistributions were found in mycorrhizas prepared by chemical fixation. Some problems related to elemental imaging are discussed.

  7. Heavy metal distribution in Suillus luteus mycorrhizas - as revealed by micro-PIXE analysis

    International Nuclear Information System (INIS)

    Turnau, K.; Przybylowicz, W.J.; Mesjasz-Przybylowicz, J.

    2001-01-01

    Suillus luteus/Pinus sylvestris mycorrhizas, collected from zinc wastes in Southern Poland, were selected as potential biofilters on the basis of earlier studies carried out with energy dispersive spectrometry (EDS) microanalytical system coupled to scanning electron microscope (SEM) and transmission electron microscope (TEM). Using the National Accelerator Centre (NAC) nuclear microprobe, elemental concentrations in the ectomycorrhiza parts were for the first time estimated quantitatively. Micro-proton-induced X-ray emission (PIXE) true elemental maps from freeze-dried and chemically fixed mycorrhizas revealed strong accumulation of Ca, Fe, Zn and Pb within the fungal mantle and in the rhizomorph. Vascular tissue was enriched with P, S and K, while high concentrations of Si and Cl were present in the endodermis. Cu was the only element showing elevated concentrations in the cortex region. Elemental losses and redistributions were found in mycorrhizas prepared by chemical fixation. Some problems related to elemental imaging are discussed

  8. PIXE and PIGE analysis of pre-colonial pottery from Patanal - MS, Brazil

    International Nuclear Information System (INIS)

    Felicissimo, M.P.; Rodrigues-Filho, U.P.; Peixoto, J.L.; Barbosa, M.S.; Demortier, G.; Pireaux, J.J.

    2006-01-01

    PIXE and PIGE were applied to investigate the pottery from two archaeological sites located near the Brazil-Bolivia border in Pantanal, an area of natural preservation. The region was inhabited by ancient Amerindian tribes long before the Latin America colonization period and a deep understanding of their environment, cultural attributes and interconnections can only be achieved based on the study of archaeological findings. Multivariate statistical procedures were used to determine similarities and correlations between the analyzed samples and to indicate possible sources of raw material provenience. The results showed that traces of Cr, Cu and Ti and Na/Si and Mg/Si counting ratios were important to distinguish sherds from the archaeological sites MS-CP-71 and MS-CP-61. (author)

  9. Trace element analysis in an optimized set-up for total reflection PIXE (TPIXE)

    International Nuclear Information System (INIS)

    Van Kan, J.A.; Vis, R.D.

    1996-01-01

    A newly constructed chamber for measuring with MeV proton beams at small incidence angles (0 to 35 mrad) is used to analyse trace elements on flat surfaces such as Si wafers, quartz substrates and perspex. This set-up is constructed in such a way that the X-ray detector can reach very large solid angles, larger than 1 sr. Using these large solid angles in combination with the reduction of bremsstrahlungs background, lower limits of detection (LOD) using TPIXE can be obtained as compared with PIXE in the conventional geometry. Standard solutions are used to determine the LODs obtainable with TPIXE in the optimized set-up. These solutions contain traces of As and Sr with concentrations down to 20 ppb in an insulin solution. The limits of detection found are compared with earlier ones obtained with TPIXE in a non optimized set-up and with TXRF results. (author)

  10. Characterization of regional atmospheric aerosols over Hungary by PIXE elemental analysis. Appendix 9

    International Nuclear Information System (INIS)

    Koltay, E.; Borbely-Kiss, I.; Szabo, Gy.; Kiss, A.Z.; Rajta, I.; Somorjai, E.; Meszaros, E.; Molnar, A.; Bozo, L.

    1995-01-01

    Earlier PIXE analytical data obtained on rural aerosol samples from Hungary have been extended by the results of further analyses in the frame of the present international Co-ordinated Research Programme. Samples have been collected in three more rural, one suburban and two urban stations. A comparison of the data revealed the distribution of aerosol loading by several trace elements over the country, supported the determination of aerosol budget indicating long-range transport from industrial sources and Saharan dust intrusion. The data show that Hungarian air is moderately polluted by aerosols from regional and faraway sources. Methodological results have been obtained in setting up a new microbeam channel for individual characterization of aerosol particles. (author)

  11. Trace element analysis of the scalp hair from pregnant women by PIXE

    International Nuclear Information System (INIS)

    Zeng Xianzhou; Yao Huiying; Yuan Aina; Zhao Huiyang

    1986-01-01

    On the basis of a self-comparison method for each individual, a study on the changes of the elemental concentrations in the scalp hair from pregnant women before and after childbirth was made by PIXE. The hair samples were collected from 10 young mothers about 3 months after the delivery of their first child. In the control group, the hair samples from 11 normal girls were collected and analyzed in the same manner. Experimental results show that no significant changes of the trace element Cu and Zn concentrations in the hair correlated with pregnancy were observed while remarkable changes in the Ca, Fe and Mn concentrations in the hair before and after delivery were found. These results were compared with previously published data on the changes of the corresponding elements during pregnancy in serum

  12. An attempt to determine positions of aerosol source by the PIXE analysis

    International Nuclear Information System (INIS)

    Matsuyama, S.; Tokai, Y.; Ishii, K.

    1999-01-01

    Aerosols were continuously collected for 2 or 3 hours during the periods of 4-27 August 1997 and of 23 March-2 April 1998 at a suburb of Sendai City (east 10 km from Sendai), and meteorological data such as wind directions, wind velocities, etc were measured at the same time. The collected aerosol samples were analyzed by the particle-induced X-ray emission (PIXE) method. Fourteen elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Hg and Pb) were contained in these samples. The elemental concentrations increased in the daytime and decreased at night. It coincided with the time variation of people movement. The concentrations of Mn, Fe, Zn and Pb elements depended strongly on the direction of wind and their distributions for wind directions reflected to the position of aerosol sources. This result suggests that the position of aerosol source can be determined by measuring aerosols and wind directions at the many positions. (author)

  13. Micro-PIXE analysis in invasive ductal carcinoma tissues after treatment of astaxanthin

    International Nuclear Information System (INIS)

    Safaverdi, S.; Roshani, F.; Lamehi Rashti, M.; Golkhoo, Sh.; Hassan, Z. M.; Langroudi, L.

    2009-01-01

    Trace elements play an important role in a number of biological processes. Astaxanthin, a carotoid pigment found in certain marine plant and animals, has shown anti cancer and anti free radical properties. This work intended to understand the effect of Astaxanthin in breast cancer (invasive ductal carcinoma) by using micro-PIXE method. For this aim the concentration of trace elements were compared in healthy, cancerous and cancer treated with astaxanthin in the breast and liver tissues of breast cancer bearing mice, using proton induced X-ray emission. Materials and Methods: Proton induced X-ray emission was used In a study intending to compare the concentration of trace elements in breast and liver tissues of mice bearing tumor, three groups of mice: healthy, cancerous, and cancerous treated by astaxanthin, were considered. Astaxanthin was supplied from Research Institute of women, Alzahra University. Results: Comparing the untreated tumor tissue, treatment with Astaxanthm significantly decreased the amount Fe, P, S, and Ca elements level in tumor tissue of the breast cancer. It is also found that the concentrations of those elements in liver of the untreated mice and the liver of treated mice with astaxanthin were fairly equal. Astaxanthln significantly decrease the accumulation of elements in the site of tumor, and caused the breast cancer cell membrane to lose their desire to collect the elements from healthy tissues. Conclusion: The micro -PIXE technique could calculate elemental concentrations in tissues. Changes in metallic elements may affect microenvironment and cell functions, which might led lead to cell degeneration or death, the results shows that astaxanthin reduces vital element concentration in tumor site, thus it could be used as an anti tumor agent.

  14. Pix proteins and the evolution of centrioles.

    Directory of Open Access Journals (Sweden)

    Hugh R Woodland

    Full Text Available We have made a wide phylogenetic survey of Pix proteins, which are constituents of vertebrate centrioles in most eukaryotes. We have also surveyed the presence and structure of flagella or cilia and centrioles in these organisms, as far as is possible from published information. We find that Pix proteins are present in a vast range of eukaryotes, but not all. Where centrioles are absent so are Pix proteins. If one considers the maintenance of Pix proteins over evolutionary time scales, our analysis would suggest that their key function is to make cilia and flagella, and the same is true of centrioles. Moreover, this survey raises the possibility that Pix proteins are only maintained to make cilia and flagella that undulate, and even then only when they are constructed by transporting ciliary constituents up the cilium using the intraflagellar transport (IFT system. We also find that Pix proteins have become generally divergent within Ecdysozoa and between this group and other taxa. This correlates with a simplification of centrioles within Ecdysozoa and a loss or divergence of cilia/flagella. Thus Pix proteins act as a weathervane to indicate changes in centriole function, whose core activity is to make cilia and flagella.

  15. Pix proteins and the evolution of centrioles.

    Science.gov (United States)

    Woodland, Hugh R; Fry, Andrew M

    2008-01-01

    We have made a wide phylogenetic survey of Pix proteins, which are constituents of vertebrate centrioles in most eukaryotes. We have also surveyed the presence and structure of flagella or cilia and centrioles in these organisms, as far as is possible from published information. We find that Pix proteins are present in a vast range of eukaryotes, but not all. Where centrioles are absent so are Pix proteins. If one considers the maintenance of Pix proteins over evolutionary time scales, our analysis would suggest that their key function is to make cilia and flagella, and the same is true of centrioles. Moreover, this survey raises the possibility that Pix proteins are only maintained to make cilia and flagella that undulate, and even then only when they are constructed by transporting ciliary constituents up the cilium using the intraflagellar transport (IFT) system. We also find that Pix proteins have become generally divergent within Ecdysozoa and between this group and other taxa. This correlates with a simplification of centrioles within Ecdysozoa and a loss or divergence of cilia/flagella. Thus Pix proteins act as a weathervane to indicate changes in centriole function, whose core activity is to make cilia and flagella.

  16. Element analysis of the eutardigrades Richtersius coronifer and Milnesium cf. asiaticum using Particle Induced X-ray Emission (PIXE

    Directory of Open Access Journals (Sweden)

    Charlotta Nilsson

    2013-05-01

    Full Text Available Semi-terrestrial tardigrades are well-known for their tolerance to a variety of environmental extremes, including desiccation, freezing and radiation. Despite several attempts to reveal the genetic and molecular mechanisms behind the resilience of tardigrades, it is still unknown how these animals are able to maintain the integrity of their cellular components under severe stress. Quantitative or qualitative changes in molecular compounds (e.g., carbohydrates, proteins are expected, and have been the main line of research towards understanding the tolerance of tardigrades. In radiation tolerant bacteria, a tolerance mechanism based on manganese has been proposed. We evaluate this hypothesis in tardigrades and provide the first data on element composition in desiccated and non-desiccated specimens of two eutardigrade species, Richtersius coronifer and Milnesium cf. asiaticum. A focused 2 MeV proton microbeam was utilised to determine the elemental content, distributions and concentrations, using the ion beam analytical technique particle induced X-ray emission (PIXE. The presence of six elements – phosphorus, sulphur, chlorine, potassium, calcium and iron – were confirmed in all tardigrade specimens, at levels up to a few mg g–1. However, manganese was found in less than 10% of the analysed specimens, and in low amounts, thus our study provides no evidence for the manganese hypothesis. We also show that the distributions and/or concentrations of some elements differ between the two species as well as between the dehydrated and hydrated state. In particular, very low levels of iron were found in dehydrated M. cf. asiaticum. Our analysis shows that the PIXE technique is a useful tool for investigating questions on the distribution of elements both in dehydrated and hydrated tardigrades.

  17. Freeze-substitution methods for Ni localization and quantitative analysis in Berkheya coddii leaves by means of PIXE

    International Nuclear Information System (INIS)

    Budka, D.; Mesjasz-PrzybyIowicz, J.; Tylko, G.; PrzybyIowicz, W.J.

    2005-01-01

    Leaves of Ni hyperaccumulator Berkheya coddii were chosen as a model to investigate the influence of eight freeze-substitution protocols on the Ni content and distribution. Freeze-substitution of leaf samples cryofixed by high-pressure freezing was carried out in dry acetone, methanol, diethyl ether and tetrahydrofuran. The same substitution media were also used with dimethylglyoxime added as a precipitation reagent. The samples were infiltrated and embedded in Spurr's resin. Micro-PIXE analysis of Ni concentration and localization, complemented by proton backscattering for matrix assessment, was performed using the nuclear microprobe at Materials Research Group, iThemba LABS, South Africa. True elemental maps and concentrations were obtained using GeoPIXE-II software. The results were compared with the control results obtained for the parallel air-dried samples, corrected for the water content. The highest Ni content was found in the leaf samples substituted in diethyl ether. This concentration was statistically different from the results obtained for other media. In case of diethyl ether medium Ni was mainly localized in the mesophyll tissue, and the distribution map of this element was in accordance with previous results obtained for freeze-dried and frozen-hydrated leaves of this species. The same distribution pattern was observed for specimens embedded in dry acetone, but Ni concentration was significantly lower. Tetrahydrofuran medium preserved Ni preferentially in the epidermis and vascular tissue, and the elemental map for samples embedded in this medium was distorted. Ni was almost completely washed out from samples substituted in methanol and it was thus impossible to obtain a picture of its distribution. Dimethylglyoxime did not improve the preservation of this element. These results show that diethyl ether is a suitable substitution medium for assessment of Ni concentration and distribution in leaves of B. coddii

  18. PIXE macro and microprobe techniques in archaeometry

    International Nuclear Information System (INIS)

    Brissaud, I.; Lagarde, G.; Houdayer, A.

    1987-01-01

    PIXE analysis method is applied to archaeometry problems. Advantages and disadvantages are emphasized. Some examples are presented which show the difficulties: especially important heterogeneities of ceramics, old coins and metals restrain from the use of this technique. Other analysis systems, less expensive, like electron microbrobe or x-ray fluorescence spectrometry, are compared with conventional PIXE method. The importance of proton microprobe is explained. (author) 40 refs.; 7 figs.; 5 tabs

  19. Electrostatic analysis of 750 keV DC accelerator

    International Nuclear Information System (INIS)

    Kumar, Abhay; Dwivedi, Jishnu; Jana, Arup Ratan

    2011-01-01

    The indigenously developed 750 keV DC accelerator working at RRCAT for the last 5 years uses SF 6 at 6 bar pressure as the insulating gas. The green house potential of this gas is about 22,000 times more than that of CO 2 gas. An electrostatic analysis of this accelerator was performed in order to probe the necessity of using this gas with a very elaborate gas handling system. The DC accelerator is approximated by a 2-D axisymmetric model in ANSYS and voltages were defined at the individual stages of the accelerating tube. The result of the study shows that the present design needs SF 6 gas and the pressure vessel dimensions need to be modified to operate the DC accelerator with environmentally friendly N 2 -CO 2 mixture. This paper presents the methodology of the analysis, discusses the DC accelerator finite element model and presents the results of the analysis. The paper also proposes changes in the DC accelerator design to run the accelerator with N 2 -CO 2 mixture. (author)

  20. Molecular electrostatic potential analysis of non-covalent complexes

    Indian Academy of Sciences (India)

    Chemical Sciences and Technology Division and Academy of Scientific & Innovative Research (AcSIR), ... workers proposed the electrostatic-covalent model of hydrogen bonding. ..... tain degree of electron donation and acceptance occurs.

  1. Two dimensional kinetic analysis of electrostatic harmonic plasma waves

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca-Pongutá, E. C.; Ziebell, L. F.; Gaelzer, R. [Instituto de Física, UFRGS, 91501-970 Porto Alegre, RS (Brazil); Yoon, P. H. [IPST, University of Maryland, College Park, Maryland 20742 (United States); SSR, Kyung Hee University, Yongin, Gyeonggi 446-701 (Korea, Republic of)

    2016-06-15

    Electrostatic harmonic Langmuir waves are virtual modes excited in weakly turbulent plasmas, first observed in early laboratory beam-plasma experiments as well as in rocket-borne active experiments in space. However, their unequivocal presence was confirmed through computer simulated experiments and subsequently theoretically explained. The peculiarity of harmonic Langmuir waves is that while their existence requires nonlinear response, their excitation mechanism and subsequent early time evolution are governed by essentially linear process. One of the unresolved theoretical issues regards the role of nonlinear wave-particle interaction process over longer evolution time period. Another outstanding issue is that existing theories for these modes are limited to one-dimensional space. The present paper carries out two dimensional theoretical analysis of fundamental and (first) harmonic Langmuir waves for the first time. The result shows that harmonic Langmuir wave is essentially governed by (quasi)linear process and that nonlinear wave-particle interaction plays no significant role in the time evolution of the wave spectrum. The numerical solutions of the two-dimensional wave spectra for fundamental and harmonic Langmuir waves are also found to be consistent with those obtained by direct particle-in-cell simulation method reported in the literature.

  2. Element analysis of teeth from children with and without cystic fibrosis by PIXE-PIGE

    International Nuclear Information System (INIS)

    Cua, F.T.

    1990-01-01

    The objective of this research is to determine whether there is a difference in the Ca, P, Fe, F, Mg, and Sr concentrations in teeth from children with and without cystic fibrosis (CF) as a function of age, sex of the child, maternal smoking habit, maternal drinking habit, and fluoridation of water supply. The nuclear analytical methods used were Proton-Induced X-Ray Emission (PIXE) and Proton-Induced Gamma Emission (PIGE). The findings are: (1) the concentration of Mg is higher in the teeth of children with cystic fibrosis who took antibiotics other than tetracycline (CF+NT) than in non-cystic fibrosis (NCF) teeth for the 'female' category; (2) P concentration is less in (CF+NT) teeth for the 'age greater than ten' group; (3) Fe concentration is greater for females in the NCF group; (4) Ca and Fe concentrations are lower for CF than for NCF in the 'mother smokes' group; (5) F and Sr concentrations for CF+NT are higher for the 'mother drinks' group than for the 'mother does not drink' group; (6) 'mother smokes' shows a depletion of Ca and Fe compared to 'mother does not smoke' for CF+NT. (7) 'fluoridation of water supply' shows an increase in F, except for NCF teeth. (author)

  3. Trace elemental analysis in cancer-afflicted tissues of penis and testis by PIXE technique

    Energy Technology Data Exchange (ETDEWEB)

    Naga Raju, G.J. [Swami Jnanananda Laboratories for Nuclear Research, Andhra University, Visakhapatnam 530 003 (India); John Charles, M. [Swami Jnanananda Laboratories for Nuclear Research, Andhra University, Visakhapatnam 530 003 (India); Bhuloka Reddy, S. [Swami Jnanananda Laboratories for Nuclear Research, Andhra University, Visakhapatnam 530 003 (India)]. E-mail: sbr_r@yahoo.com; Sarita, P. [Swami Jnanananda Laboratories for Nuclear Research, Andhra University, Visakhapatnam 530 003 (India); Seetharami Reddy, B. [Swami Jnanananda Laboratories for Nuclear Research, Andhra University, Visakhapatnam 530 003 (India); Rama Lakshmi, P.V.B. [Pathology Department, Andhra Medical College, Visakhapatnam 530 002 (India); Vijayan, V. [Institute of Physics, Sachivalaya Marg, Bhubaneswar 751 001 (India)

    2005-04-01

    PIXE technique was employed to estimate the trace elemental concentrations in the biological samples of cancerous penis and testis. A 3 MeV proton beam was employed to excite the samples. From the present results it can be seen that the concentrations of Cl, Fe and Co are lower in the cancerous tissue of the penis when compared with those in normal tissue while the concentrations of Cu, Zn and As are relatively higher. The concentrations of K, Ca, Ti, Cr, Mn, Br, Sr and Pb are in agreement within standard deviations in both cancerous and normal tissues. In the cancerous tissue of testis, the concentrations of K, Cr and Cu are higher while the concentrations of Fe, Co and Zn are lower when compared to those in normal tissue of testis. The concentrations of Cl, Ca, Ti and Mn are in agreement in both cancerous and normal tissues of testis. The higher levels of Cu lead to the development of tumor. Our results also support the underlying hypothesis of an anticopper, antiangiogenic approach to cancer therapy. The Cu/Zn ratios of both penis and testis were higher in cancer tissues compared to that of normal.

  4. PIXE analysis of airborne particulate matter from Monterrey, Mexico. A first survey

    International Nuclear Information System (INIS)

    Aldape, F.; Flores M, J.; Diaz, R.V.; Hernandez-Mendez, B.; Montoya Z, J.M.; Blanco, E.E.; Fuentes, A.F.; Torres-Martinez, L.M.

    1999-01-01

    A first survey of elemental contents in airborne particulate matter from Monterrey, Nuevo Leon, Mexico, was performed using PIXE. This second largest industrial city is located 715 km north of Mexico City, and counts with a population of nearly three million inhabitants in its conurbation. Air pollution in the place comes from a great variety of industries ranging from iron smelters to furniture manufacturing, as well as from fuel combustion in vehicles and industries. This study presents results of elemental contents in airborne particulate matter in two particle size fractions: PM 2.5 and PM 15 . The samples were collected during five weeks on working days, Monday-Friday, from 9 December 1996 to 14 January 1997. Two samples a day were collected, 12 h each, night-time and day-time. These first results show local pollution as typical from a large urban area in conjunction with an active industry. Thirteen elements were consistently detected in most of the samples and some episodes due to both industrial and human activities were identified. A general discussion about the results obtained is presented

  5. PIXE analysis of trace elements in human hair of patients with liver disorders

    International Nuclear Information System (INIS)

    Bolormaa, O.; Tsuji, M.; Kawasaki, K.; Narantsetseg, S.; Hattori, T.

    2006-01-01

    Human hairs of cirrhosis, acute viral hepatitis patients and healthy people in Ulaanbaatar, capital city of Mongolia, were analyzed for the presence of heavy elements by PIXE spectrometry using 2.5 MeV proton beam at the Tokyo Institute of Technology Van de Graaff Laboratory. The samples were dissolved in a mixture of nitric acid and hydrogen peroxide. Then a 20μl aliquot was dropped on a Nuclepore Track-etch Membrane. The IAEA Reference Hair IAEA-086 certified reference material was used in order to verify accuracy of the method and the results were in good agreement with the certified values. To determine the interaction among nine elements in hair, correlation coefficients were evaluated for several pairs of elements. in the group of healthy control, no correlation between elements was identified. Opposite to this, the strong positive correlations were observed for Zn and Ca or Fe; Mn and Ca or Ti; Sr and Zn or Fe in the patients hair. In the present study, the mean concentrations of Ca, Ti, As and Sr in Mongolian patients were higher than those in the hair of normal people in Japan, Mongolia, Iran and Indonesia. The levels of Cu, Zn and Mn concentration in hair of normal people were almost the same for all the cohorts. (Author)

  6. Pollution assessment in the Trancao river basin (Portugal) by PIXE, EDXRF and isotopic analysis

    International Nuclear Information System (INIS)

    Pinheiro, T.; Araujo, M.F.; Carreira, P.M.; Valerio, P.; Nunes, D.; Alves, L.C.

    1999-01-01

    This paper reports on the inorganic contamination assessment of a river basin and local water resources in order to establish quality standards. PIXE was applied to the elemental determination of the freeze-dried water dry residue and EDXRF was used for the evaluation of elemental content of sediments. To infer the water provenance the electrical conductivity was measured as well as the isotopic composition of surface waters using the 18 O/ 16 O ratio. The combined isotopic and elemental composition information enables to establish dominant contamination contributions from the several tributaries. Moreover, the variability observed for certain parameters, associates them with specific basin regions as for instance, dry residue mass, conductivity and Br, or S, Cl and As or Cr, Ni, Zn and Pb which permit to establish both pollution characterisation and their origin (agriculture, industrial, etc.). At certain locations, enhanced concentrations of elements as Cr, Cu, Zn and Pb are observed both in sediments and in the surface water. The elemental particular associations also permit to characterise pollution sources

  7. PIXE analysis of some anti-diabetic medicinal plants in Nigeria

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Omobuwajo, O.R.; Adebajo, A.C.; Ceccato, D.; Buoso, M.C.; Moschini, G.

    2013-01-01

    Full text: Diabetes mellitus, a metabolic disease characterized by high blood glucose levels (hyperglycemia) due to defects in insulin secretion, or action, or both. It is a dangerous disease leading to death of many people in the world. Some of the medicinal plants implicated in the herbal recipes for the treatment of diabetes in Nigeria have been reported 1 . Additional medicinal plants used for the treatment of diabetes in Nigeria are presented in this work. These medicinal plants are becoming increasingly important and relevant as herbal drugs due to their use as antioxidants, neutraceuticals, food additives and supplements in combating diabetes. Elemental compositions of these anti-diabetic medicinal plants were determined using PIXE technique. The 1.8 MV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator at Instituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL) Legnaro (Padova) Italy was employed for the work. The results show the presence of twenty two elements at various concentrations in the medicinal plants. The leaves of Murraya, P amarus, O. gratissimum, O.subscopodica, P pellucida and the whole plant of B. diffusa, B. pinnalum and C. occidenlalis could be taken as vegetables, food additives, neutraceuticals and supplements in the management of diabetes. [1] S.O. Olabanji, OR Omobuwajo, D. Ceccato, A.C. Adebajo, M.C. Buoso, G. Moschini. Nucl. Instrum. Methods Phys. Res. Sect. B 266 (2008) 2387 - 2390. (author)

  8. PIXE analysis of some anti-diabetic medicinal plants in Nigeria

    Energy Technology Data Exchange (ETDEWEB)

    Olabanji, S.O. [ICTP Fellow on sabbatical leave from Centre for Energy Research and Development, Obafemi Awolowo University, lIe-lfe (Nigeria); Omobuwajo, O.R.; Adebajo, A.C. [Department of Pharmacognosy, Faculty of Pharmacy, Obafemi Awolowo University, lIe-lfe (Nigeria); Ceccato, D. [Dipartmento di Fisica, Universita di Padova, Padova (Italy); Buoso, M.C.; Moschini, G., E-mail: skayode2002@yahoo.co.uk [lstituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), Padova (Italy)

    2013-07-01

    Full text: Diabetes mellitus, a metabolic disease characterized by high blood glucose levels (hyperglycemia) due to defects in insulin secretion, or action, or both. It is a dangerous disease leading to death of many people in the world. Some of the medicinal plants implicated in the herbal recipes for the treatment of diabetes in Nigeria have been reported{sup 1}. Additional medicinal plants used for the treatment of diabetes in Nigeria are presented in this work. These medicinal plants are becoming increasingly important and relevant as herbal drugs due to their use as antioxidants, neutraceuticals, food additives and supplements in combating diabetes. Elemental compositions of these anti-diabetic medicinal plants were determined using PIXE technique. The 1.8 MV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator at Instituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL) Legnaro (Padova) Italy was employed for the work. The results show the presence of twenty two elements at various concentrations in the medicinal plants. The leaves of Murraya, P amarus, O. gratissimum, O.subscopodica, P pellucida and the whole plant of B. diffusa, B. pinnalum and C. occidenlalis could be taken as vegetables, food additives, neutraceuticals and supplements in the management of diabetes. [1] S.O. Olabanji, OR Omobuwajo, D. Ceccato, A.C. Adebajo, M.C. Buoso, G. Moschini. Nucl. Instrum. Methods Phys. Res. Sect. B 266 (2008) 2387 - 2390. (author)

  9. PIXE Analysis of Metal Hull Bolts From HMB DeBraak

    International Nuclear Information System (INIS)

    Correll, Francis D.; Cole, Lord K.; Slater, Charles J.; Vanhoy, Jeffrey R.; Fithian, Charles H.

    2009-01-01

    HMB DeBraak was a 16-gun British brig-sloop that sank in a squall on May 25, 1798 off Cape Henlopen, Delaware. Silt covered the wooden hull shortly after it sank, preserving it until DeBraak was raised in 1986. The items recovered from the ship include metal bolts that held the hull together. We used PIXE to measure the compositions of 45 of the bolts and found that they are nearly pure copper (98.3% on average), with most also containing small amounts of iron (0.87%), nickel (0.039%), arsenic (0.43%), silver (0.089%), lead (0.18%), and bismuth (0.12%). A few contain a little indium, tin, or antimony, but none contain zinc above the quantization level. The compositions are similar to those reported for 18th-century English copper, but different from several copper alloys also used to make hull bolts. We conclude that, when DeBraak was last fitted out in 1795-1797, the Royal Navy was still using bolts similar to William Forbes's mechanically hardened pure copper bolts. Forbes's process represents the successful innovation and application of new technology in Royal Navy ships during the wars of the late 18th century.

  10. PIXE Analysis of Metal Hull Bolts From HMB DeBraak

    Science.gov (United States)

    Correll, Francis D.; Cole, Lord K.; Slater, Charles J.; Vanhoy, Jeffrey R.; Fithian, Charles H.

    2009-03-01

    HMB DeBraak was a 16-gun British brig-sloop that sank in a squall on May 25, 1798 off Cape Henlopen, Delaware. Silt covered the wooden hull shortly after it sank, preserving it until DeBraak was raised in 1986. The items recovered from the ship include metal bolts that held the hull together. We used PIXE to measure the compositions of 45 of the bolts and found that they are nearly pure copper (98.3% on average), with most also containing small amounts of iron (0.87%), nickel (0.039%), arsenic (0.43%), silver (0.089%), lead (0.18%), and bismuth (0.12%). A few contain a little indium, tin, or antimony, but none contain zinc above the quantization level. The compositions are similar to those reported for 18th-century English copper, but different from several copper alloys also used to make hull bolts. We conclude that, when DeBraak was last fitted out in 1795-1797, the Royal Navy was still using bolts similar to William Forbes's mechanically hardened pure copper bolts. Forbes's process represents the successful innovation and application of new technology in Royal Navy ships during the wars of the late 18th century.

  11. PIXE analysis of airborne particulate matter from Xalostoc, Mexico: winter to summer comparison

    International Nuclear Information System (INIS)

    Flores M, J.; Aldape, F.; Diaz, R.V.; Hernandez-Mendez, B.; Garcia G, R.

    1999-01-01

    A study of elemental contents in airborne particulate matter from the industrial city of Xalostoc, Estado de Mexico, was performed using PIXE. The place has a great variety of industries, it is a heavily populated, and it is a part of Mexico City's conurbation, thus contributing significantly to its atmospheric pollution. At present, there is few information available about elemental contents in airborne particulate matter from that region. In this study, two sets of samples of airborne particulate matter were collected daily during periods of four weeks in summer 1996 and winter 1997; two samples a day, 12 h each, night-time and day-time. Results revealed important information about elemental contents in airborne particulate matter from that area, especially in the respirable fraction PM 2.5 . Comparison of night and day figures showed the presence of some elements such as Cu, Zn, and Pb, attributed, as it was expected, to uninterrupted industrial processes. Appearance of some other elements was more consistent only in either day-time or night-time due to diurnal or nocturnal industrial activities, or produced by human activities such as fuel combustion of automotive vehicles. Comparison of winter to summer results showed some other important features such as higher concentrations of pollutants in winter, because of the dry and cold weather, while summer samples exhibited lower concentrations mainly due to the presence of rain showers

  12. TXRF, PIXE and EDXRF: a first step towards normalization of x-ray spectrometry for chemical analysis

    International Nuclear Information System (INIS)

    Barreiros, M.A.; Costa, M.M.; Palha, M.; Pinheiro, T.; Araujo, M.F.; Silva, R.C. da

    2000-01-01

    Nowadays, many research studies rely on analytical measurements to which x-ray spectrometry techniques are particularly adequate. Because they are multi-elemental, versatile, fast and can reach low detection limits they are often applied to environmental and biomedical studies. Besides, they are able to provide reliable and accurate results. As also occurs with other analytical procedures, the quality assurance for non-routine analysis in R and D laboratories, is much less well established. when compared with routine analytical work. Thus, it is of foremost importance, to set the major quality parameters that significantly affect the quality of results. In addition, there is a need to apply the new concepts of trace ability and uncertainty to these techniques. This work reports on the reliability of TXRF, PIXE and EDXRF measurements by evaluating the uncertainty and trace ability for elemental analysis. The set of experimental and statistical procedures used to ensure the quality of results relative to the proposed objectives, as well as the methods applied to estimate the uncertainties will be presented and discussed. The sample preparation procedures, analytical calibration and spectral evaluation will be the parameters examined in this inter-laboratory study. The sample preparation procedures comprise pressure acid digestion and pelletizing for solid samples. The internal quality control for analytical calibration and spectral analysis is performed using certified reference materials and standard solutions. The goal of this work is to present a first step towards normalization of x-ray spectrometry techniques for chemical analysis. (author)

  13. PIXE analysis of some Nigerian anti-diabetic medicinal plants (II)

    Energy Technology Data Exchange (ETDEWEB)

    Olabanji, S.O., E-mail: skayode2002@yahoo.co.uk [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), I-35020 Padova (Italy); ICTP Fellow on Sabbatical Leave from Centre for Energy Research and Development, Obafemi Awolowo University, Ile-Ife (Nigeria); Adebajo, A. C. [Department of Pharmacognosy, Faculty of Pharmacy, Obafemi Awolowo University, Ile-Ife (Nigeria); Omobuwajo, O. R. [Department of Pharmacognosy and Herbal Medicine, Faculty of Pharmacy, Niger Delta University, Wilberforce Island (Nigeria); Ceccato, D. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), I-35020 Padova (Italy); Dipartmento di Fisica, Universita di Padova, Padova (Italy); Buoso, M. C. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), I-35020 Padova (Italy); Moschini, G. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), I-35020 Padova (Italy); Dipartmento di Fisica, Universita di Padova, Padova (Italy)

    2014-01-01

    Diabetes mellitus, a metabolic disease characterized by high blood glucose levels (hyperglycemia) due to defects in insulin secretion, or action, or both, is a debilitating disease leading to other complications and death of many people in the world. Some of the medicinal plants implicated in the herbal recipes for the treatment of diabetes in Nigeria have been reported. Additional medicinal plants used for the treatment of diabetes in Nigeria are presented in this work. These medicinal plants are becoming increasingly important and relevant as herbal drugs due to their use as antioxidants, nutraceuticals, food additives and supplements in combating diabetes. Elemental compositions of these anti-diabetic medicinal plants were determined using PIXE technique. The 1.8 MV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator at Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL) Legnaro (Padova) Italy was employed for the work. The results show the detection of twenty-one elements which include Mg, P, Ca, K, Mn, Cu, Zn, S, Cr, Co, Ni and V that are implicated in the regulation of insulin and the control of the blood-sugar levels in the human body. The entire plant of Boerhavia diffusa, Securidaca longipedunculata stem, leaves of Peperomia pellucida, Macrosphyra longistyla, Olax subscorpioidea, Phyllanthus muerillanus, Jatropha gossypifolia, Cassia occidentalis, Phyllanthus amarus, and leaf and stem of Murraya koenigii, which have high concentrations of these elements could be recommended as vegetables, nutraceuticals, food additives, supplements and drugs in the control and management of diabetes, if toxicity profiles indicate that they are safe. However, significantly high contents of Al and Si in the entire plant of Bryophyllum pinnatum, and As, Cr, and Cu in Ocimum gratissimum leaf suggest that these plants should be avoided by diabetic patients to prevent complications.

  14. PIXE analysis of some Nigerian anti-diabetic medicinal plants (II)

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Adebajo, A.C.; Omobuwajo, O.R.; Ceccato, D.; Buoso, M.C.; Moschini, G.

    2014-01-01

    Diabetes mellitus, a metabolic disease characterized by high blood glucose levels (hyperglycemia) due to defects in insulin secretion, or action, or both, is a debilitating disease leading to other complications and death of many people in the world. Some of the medicinal plants implicated in the herbal recipes for the treatment of diabetes in Nigeria have been reported. Additional medicinal plants used for the treatment of diabetes in Nigeria are presented in this work. These medicinal plants are becoming increasingly important and relevant as herbal drugs due to their use as antioxidants, nutraceuticals, food additives and supplements in combating diabetes. Elemental compositions of these anti-diabetic medicinal plants were determined using PIXE technique. The 1.8 MV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator at Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL) Legnaro (Padova) Italy was employed for the work. The results show the detection of twenty-one elements which include Mg, P, Ca, K, Mn, Cu, Zn, S, Cr, Co, Ni and V that are implicated in the regulation of insulin and the control of the blood-sugar levels in the human body. The entire plant of Boerhavia diffusa, Securidaca longipedunculata stem, leaves of Peperomia pellucida, Macrosphyra longistyla, Olax subscorpioidea, Phyllanthus muerillanus, Jatropha gossypifolia, Cassia occidentalis, Phyllanthus amarus, and leaf and stem of Murraya koenigii, which have high concentrations of these elements could be recommended as vegetables, nutraceuticals, food additives, supplements and drugs in the control and management of diabetes, if toxicity profiles indicate that they are safe. However, significantly high contents of Al and Si in the entire plant of Bryophyllum pinnatum, and As, Cr, and Cu in Ocimum gratissimum leaf suggest that these plants should be avoided by diabetic patients to prevent complications

  15. VIBA-Lab 3.0: Computer program for simulation and semi-quantitative analysis of PIXE and RBS spectra and 2D elemental maps

    Energy Technology Data Exchange (ETDEWEB)

    Orlić, Ivica; Mekterović, Darko [Department of Physics, University of Rijeka, Radmile Matejčić 2, 51000 Rijeka (Croatia); Mekterović, Igor [Faculty of Electrical Engineering and Computing, University of Zagreb (Croatia); Ivošević, Tatjana [Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka (Croatia)

    2015-11-15

    VIBA-Lab is a computer program originally developed by the author and co-workers at the National University of Singapore (NUS) as an interactive software package for simulation of Particle Induced X-ray Emission and Rutherford Backscattering Spectra. The original program is redeveloped to a VIBA-Lab 3.0 in which the user can perform semi-quantitative analysis by comparing simulated and measured spectra as well as simulate 2D elemental maps for a given 3D sample composition. The latest version has a new and more versatile user interface. It also has the latest data set of fundamental parameters such as Coster–Kronig transition rates, fluorescence yields, mass absorption coefficients and ionization cross sections for K and L lines in a wider energy range than the original program. Our short-term plan is to introduce routine for quantitative analysis for multiple PIXE and XRF excitations. VIBA-Lab is an excellent teaching tool for students and researchers in using PIXE and RBS techniques. At the same time the program helps when planning an experiment and when optimizing experimental parameters such as incident ions, their energy, detector specifications, filters, geometry, etc. By “running” a virtual experiment the user can test various scenarios until the optimal PIXE and BS spectra are obtained and in this way save a lot of expensive machine time.

  16. VIBA-Lab 3.0: Computer program for simulation and semi-quantitative analysis of PIXE and RBS spectra and 2D elemental maps

    International Nuclear Information System (INIS)

    Orlić, Ivica; Mekterović, Darko; Mekterović, Igor; Ivošević, Tatjana

    2015-01-01

    VIBA-Lab is a computer program originally developed by the author and co-workers at the National University of Singapore (NUS) as an interactive software package for simulation of Particle Induced X-ray Emission and Rutherford Backscattering Spectra. The original program is redeveloped to a VIBA-Lab 3.0 in which the user can perform semi-quantitative analysis by comparing simulated and measured spectra as well as simulate 2D elemental maps for a given 3D sample composition. The latest version has a new and more versatile user interface. It also has the latest data set of fundamental parameters such as Coster–Kronig transition rates, fluorescence yields, mass absorption coefficients and ionization cross sections for K and L lines in a wider energy range than the original program. Our short-term plan is to introduce routine for quantitative analysis for multiple PIXE and XRF excitations. VIBA-Lab is an excellent teaching tool for students and researchers in using PIXE and RBS techniques. At the same time the program helps when planning an experiment and when optimizing experimental parameters such as incident ions, their energy, detector specifications, filters, geometry, etc. By “running” a virtual experiment the user can test various scenarios until the optimal PIXE and BS spectra are obtained and in this way save a lot of expensive machine time.

  17. VIBA-Lab 3.0: Computer program for simulation and semi-quantitative analysis of PIXE and RBS spectra and 2D elemental maps

    Science.gov (United States)

    Orlić, Ivica; Mekterović, Darko; Mekterović, Igor; Ivošević, Tatjana

    2015-11-01

    VIBA-Lab is a computer program originally developed by the author and co-workers at the National University of Singapore (NUS) as an interactive software package for simulation of Particle Induced X-ray Emission and Rutherford Backscattering Spectra. The original program is redeveloped to a VIBA-Lab 3.0 in which the user can perform semi-quantitative analysis by comparing simulated and measured spectra as well as simulate 2D elemental maps for a given 3D sample composition. The latest version has a new and more versatile user interface. It also has the latest data set of fundamental parameters such as Coster-Kronig transition rates, fluorescence yields, mass absorption coefficients and ionization cross sections for K and L lines in a wider energy range than the original program. Our short-term plan is to introduce routine for quantitative analysis for multiple PIXE and XRF excitations. VIBA-Lab is an excellent teaching tool for students and researchers in using PIXE and RBS techniques. At the same time the program helps when planning an experiment and when optimizing experimental parameters such as incident ions, their energy, detector specifications, filters, geometry, etc. By "running" a virtual experiment the user can test various scenarios until the optimal PIXE and BS spectra are obtained and in this way save a lot of expensive machine time.

  18. Characterization and application of automated in-vacuum PIXE/EBS system for direct analysis of chloride and sulfate ions attack in cementitious materials

    Science.gov (United States)

    Rihawy, M. S.; Alwazzeh, M.; Abbas, K.

    2018-01-01

    Ion beam analysis (IBA) techniques (Particle Induced X-ray Emission, PIXE and Elastic Backscattering Spectrometry, EBS), were applied to investigate chloride and sulfate ions diffusion into laboratory prepared mortar samples. Development and characterization of an automated in-vacuum macro PIXE/EBS system is thoroughly discussed. Depth profile information of both chloride and sulfate ions in laboratory prepared mortar samples, after immersion in sea water for nine months, was rapidly and easily obtained at fairly low cost and with standardless analysis, demonstrating the value of the application of IBA to elemental depth profiling in cementitious materials. Chloride and sulfate depth profiles were obtained for two sets of mortar samples, one prepared with different water/cement (W/C) ratios and the other with different sand/cement (S/C) ratios. Results showed higher diffusion rates of both chloride and sulfate ions when both ratios are increased. Additionally, the W/C ratio has a stronger influence in both sulfate and chloride penetration than the S/C ratio, and chloride ions penetrate faster than sulfates. Advantages and limitations of applying IBA techniques in this investigation are discussed. The comparison between PIXE and other X-ray based analytical techniques, namely X-ray fluorescence (XRF) and energy and wavelength dispersive X-rays (EDX/WDX), as well as other traditional wet chemical methods is reviewed, and industrial applications are discussed.

  19. Dating and classification of Syrian excavated pottery from Tell Saka Site, by means of thermoluminescence analysis, and multivariate statistical methods, based on PIXE analysis

    International Nuclear Information System (INIS)

    Bakraji, E.H.; Ahmad, M.; Salman, N.; Haloum, D.; Boutros, N.; Abboud, R.

    2011-01-01

    Thermoluminescence (TL) dating and Proton Induced X-ray Emission (PIXE) techniques have been utilized for the study of archaeological pottery fragment samples from Tell Saka Site, which is located at 25 km south east of Damascus city, Syria. Four samples were chosen randomly from the site, two from third level and two from fourth level for dating using TL technique and the results were in good agreement with the date assigned by archaeologists. Twenty-eight sherds were analyzed using PIXE technique in order to identify and characterize the elemental composition of pottery excavated from third and fourth levels, using 3 MV tandem accelerator in Damascus. The analysis provided almost 20 elements (Na, Mg, Al, Si, P, S, K, Ca, Ti, Mn, Fe, Co, Ni, Cu, Zn, Rb, Sr, Y, Zr, Nb). However, only 14 elements as follows: K, Ca, Ti, Mn, Fe, Co, Ni, Cu, Zn, Rb, Sr, Y, Zr, Nb were chosen for statistical analysis and have been processed using two multivariate statistical methods, Cluster and Factor analysis. The studied pottery were classify into two well defined groups. (author)

  20. Study of talcum charging status in parallel plate electrostatic separator based on particle trajectory analysis

    Science.gov (United States)

    Yunxiao, CAO; Zhiqiang, WANG; Jinjun, WANG; Guofeng, LI

    2018-05-01

    Electrostatic separation has been extensively used in mineral processing, and has the potential to separate gangue minerals from raw talcum ore. As for electrostatic separation, the particle charging status is one of important influence factors. To describe the talcum particle charging status in a parallel plate electrostatic separator accurately, this paper proposes a modern images processing method. Based on the actual trajectories obtained from sequence images of particle movement and the analysis of physical forces applied on a charged particle, a numerical model is built, which could calculate the charge-to-mass ratios represented as the charging status of particle and simulate the particle trajectories. The simulated trajectories agree well with the experimental results obtained by images processing. In addition, chemical composition analysis is employed to reveal the relationship between ferrum gangue mineral content and charge-to-mass ratios. Research results show that the proposed method is effective for describing the particle charging status in electrostatic separation.

  1. Applications of PIXE in dendrochronology

    International Nuclear Information System (INIS)

    Revesz, P.; Mayer, J.W.; Vizkelethy, G.; Kuniholm, P.I.; Griggs, C.B.; Kuniholm, H.E.; Newton, M.W.; Tarter, S.L.

    1991-01-01

    The Bard Hall Ion Beam Facility has developed external proton beams at 1-3 MeV for ion-induced x-ray emission studies of artists' pigments and metallic printers inks. The authors have extended these PIXE measurements to analysis of Athenian Tetradrachms (5th and 6th centuries BC). In both pigment and coin studies they have compared PIXE analyses with those from XRF and electron micro probe for calibration purposes. The Aegean Dendrochronology Project has developed over 5500 years of tree-ring chronologies for the Aegean, Balkans, and Eastern Mediterranean. Included are forest sites adjacent to mining and smelting operations, also sites at the upper timberline where the annual growth-rings might be expected to have picked up fallout from volcanic activity around the world. A preliminary examination of selected rings by PIXE has shown remarkable differences from year to year in the deposition of various elements, notable Zn, Fe, and Cu. The authors propose to look at a number of selected annual ring sequences to see (1) whether one can chart the progress of known metallurgical activity; (2) whether one can find evidence for volcanic effects, both for absolutely-dated volcanoes such as Krakatoa, Tambora, and Sumbawa, and for problematic volcanoes such as Santorini/Thera

  2. Direct Analysis of Large Living Organism by Megavolt Electrostatic Ionization Mass Spectrometry

    Science.gov (United States)

    Ng, Kwan-Ming; Tang, Ho-Wai; Man, Sin-Heng; Mak, Pui-Yuk; Choi, Yi-Ching; Wong, Melody Yee-Man

    2014-09-01

    A new ambient ionization method allowing the direct chemical analysis of living human body by mass spectrometry (MS) was developed. This MS method, namely Megavolt Electrostatic Ionization Mass Spectrometry, is based on electrostatic charging of a living individual to megavolt (MV) potential, illicit drugs, and explosives on skin/glove, flammable solvent on cloth/tissue paper, and volatile food substances in breath were readily ionized and detected by a mass spectrometer.

  3. Intercomparison of PIXE spectrometry software packages

    International Nuclear Information System (INIS)

    2003-02-01

    During the year 2000, an exercise was organized to make a intercomparison of widely available software packages for analysis of particle induced X ray emission (PIXE) spectra. This TECDOC describes the method used in this intercomparison exercise and presents the results obtained. It also gives a general overview of the participating software packages. This includes basic information on their user interface, graphical presentation capabilities, physical phenomena taken in account, way of presenting results, etc. No recommendation for a particular software package or method for spectrum analysis is given. It is intended that the readers reach their own conclusions and make their own choices, according to their specific needs. This TECDOC will be useful to anyone involved in PIXE spectrum analysis. This TECDOC includes a companion CD with the complete set of test spectra used for intercomparison. The test spectra on this CD can be used to test any PIXE spectral analysis software package

  4. The LLNL Multi-User Tandem Laboratory PIXE microprobe

    International Nuclear Information System (INIS)

    Heikkinen, D.W.; Bench, G.S.; Antolak, A.J.; Morse, D.H.; Pontau, A.E.

    1992-01-01

    We have recently completed the construction of a new ion beamline primarily for particle-induced x-ray emission (PIXE) analysis. This will supplement our current ion microtomography (IMT) material characterization capabilities using accelerator microanalysis. In this paper we describe the PIXE beamline and give some results that characterize the system. We also report the results of some initial experiments

  5. A study on characteristics and sources of winter time atmospheric aerosols in Kyoto and Seoul using PIXE and supplementary analysis

    International Nuclear Information System (INIS)

    Ma, C.-J.; Kasahara, M.; Tohno, S.; Yeo, H.-G.

    1999-01-01

    Atmospheric aerosols were collected using a two stages filter sampler to classify into the fine and coarse fraction in Kyoto and Seoul in winter season. Elemental concentrations of aerosols were analyzed by PIXE and EAS as well as ion concentrations by IC. Analyzed data were used to source of aerosol particles. (author)

  6. Mathematical analysis of partial differential equations modeling electrostatic MEMS

    CERN Document Server

    Esposito, Pierpaolo; Guo, Yujin

    2010-01-01

    Micro- and nanoelectromechanical systems (MEMS and NEMS), which combine electronics with miniature-size mechanical devices, are essential components of modern technology. It is the mathematical model describing "electrostatically actuated" MEMS that is addressed in this monograph. Even the simplified models that the authors deal with still lead to very interesting second- and fourth-order nonlinear elliptic equations (in the stationary case) and to nonlinear parabolic equations (in the dynamic case). While nonlinear eigenvalue problems-where the stationary MEMS models fit-are a well-developed

  7. PIXE and Moseley's law

    International Nuclear Information System (INIS)

    Huddle, James R.

    2001-01-01

    In an undergraduate atomic physics experiment, 2.8 MeV protons are used to bombard thick elemental targets. X rays emitted from the targets are detected with a Si(Li) detector, and their energies are measured with a multichannel analyzer. The Kα and Kβ x-ray energies are each plotted as functions of (Z-1) 2 , and the Rydberg energy, Rch, is extracted from the slopes of the resulting lines. The Kα plot gives Rch=14.099±0.025 eV, while the Kβ plot gives 13.557±0.027 eV. The experiment extends the Bohr Theory as discussed in class, serves to introduce PIXE as a quantitative technique for elemental analysis, gives the students experience in using modern instruments which may be used in later experiments, and experience in using uncertainty analysis to decide whether their measurements agree or disagree with other measurements or theoretical calculations. Although the experimental values differ from each other and from the accurately-known value of 13.606 eV by less than 4%, they do not agree to within the experimental uncertainties, forcing students to consider a systematic error arising from their use of the Bohr Theory to derive Moseley's Law

  8. Electrostatic Analysis of Annular Holes Penetrated by Shorted-Cable

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Jae Yul; Kim, Hyung Tae; Park, Hyun Shin; Cho, Young Sik [KINS, Daejeon (Korea, Republic of)

    2016-05-15

    The cabinet has an important role to protect the contained cables and digital modules for the safety function from the external electromagnetic (EM) source. Thus the immunity of an open cabinet against electromagnetic interference (EMI) numerically has been investigated using mode-matching method in. Another path for the external EM source to impinge on inner cables and digital modules is the bottom hole of the cabinet that is penetrated by various cables. Especially the EMI can detrimentally influence on the digital modules through annular space caused by sealing the bottom hole of the cabinet incompletely. Thus it is recently required that the electromagnetic interpretation in the annular hole is performed to remedy electromagnetic problems. Based on the mode-matching method, we solved the electrostatic boundary-value problem for holes penetrating shorted-cable at the bottom of a digital I and C cabinet. The Weber transform and the Hankel transform were applied to formulate the electrostatic potential. The capacitance and potential distribution generated near the penetrating shorted-cable were computed and compared with the result from the previous study.

  9. An open experiment of a submilli-PIXE camera

    International Nuclear Information System (INIS)

    Matsuyama, S.; Ishii, K.; Yamazaki, H.; Iwasaki, S.; Tokai, Y.; Sugimoto, A.; Endo, H.; Ozawa, T.

    1999-01-01

    We have annually held an open experiment of PIXE analysis since 1996 to get people's understanding on nuclear technology and radiation science. Up to the present, more than 270 participants joined and enjoyed the open experiments. This year, we demonstrated performance of a submilli-PIXE camera and had sixty-nine participants in the open experiment of PIXE. Elemental spatial distribution images gave deep impression to the participants. Half of the participants were high school students since the open experiment of PIXE was held during the period of open campus of Tohoku University. About ten percents of the participants were junior high school students. Our open experiment of PIXE was very effective to arouse public interest in radiation science and nuclear technology. (author)

  10. Comparison of laser microprobe mass spectrometry (LMMS) and micro particle induced x-ray emission (micro-PIXE) for the analysis of senile plaques in Alzheimer`s disease. A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Lovell, M A; Robertson, J D; Ehmann, W D [Kentucky Univ., Lexington, KY (United States). Dept. of Chemistry; Markesbery, W R [Kentucky Univ., Lexington, KY (United States); Teesdale, W J; Campbell, J L [Guelph Univ., ON (Canada). Dept. of Physics

    1995-08-01

    Results of micro-PIXE analysis of senile plaques (SP) in Alzheimer`s disease (AD) brain have been utilized to independently confirm levels of iron (Fe) as measured by LMMS in adjacent brain sections. LMMS concentrations were calculated based on the preparation and analysis of an iron calibration curve prepared in our laboratory. The LMMS standards consist of iron cis-dicylclohexano-18-crown-6 ether coordination complexes dissolved in Spurr`s low viscosity embedding medium. To our knowledge, this is the first report of the use of micro-PIXE, with its spatial resolution and detection limits comparable to that of LMMS, in the validation of LMMS results. The agreement observed between results obtained for Fe by micro-PIXE and LMMS indicates that the use of our LMMS standards, at least in the case of Fe, yields accurate results. (author). 6 refs., 1 fig., 1 tab.

  11. (d, p) reactions and the combination of PIXE-PIGME techniques for the analysis of biomass samples

    International Nuclear Information System (INIS)

    Fakhouri, H.G.; Dyson, N.A.

    1989-01-01

    To control environmental pollution, a biodegradation technique involving a biomass is used to degrade the liquid wastes from certain industrial processes before disposal. (d, p) reactions were used to study the degradation process and the extent of removal of carbon and nitrogen. The PIXE-PIGME technique was used for the simultaneous study of the compositions of the biomass, the feed and the treated material. Measurements were obtained using protons of 2.5 MeV (for the the PIXE-PIGME measurements) and deuterons of 2.0 MeV using currents of the order of 25nA. The X-ray and γ-ray data were recorded simultaneously. Absolute concentrations were obtained by comparison with measurements of calibration standards. Results show that 54-58% of the carbon and 45-50% of the nitrogen is removed from the wastes and that the biomass is concentrating Cl, Ti, Ni and Fe. (author) 4 refs.; 8 figs

  12. Application of PIXE in pollution control of the Matola River in Mozambique-analysis of fish scales

    Energy Technology Data Exchange (ETDEWEB)

    Guambe, J.F. [Freshwater Research Unit, Department of Zoology, University of Cape Town, Private Bag, Rondebosch 7701 (South Africa); Departamento de Fisica, Universidade Edouardo Mondlane, C.P. 257, Maputo (Mozambique); Materials Research Department, iThemba LABS, P.O. Box 722, Somerset West 7129 (South Africa); Mars, J.A., E-mail: marsja@cput.ac.za [Faculty of Health and Wellness Sciences, Cape Peninsula University of Technology, P.O. Box 1906, Bellville 7535 (South Africa); Day, J. [Freshwater Research Unit, Department of Zoology, University of Cape Town, Private Bag, Rondebosch 7701 (South Africa)

    2012-02-15

    Since PIXE is able to distinguish concentrations of elements at very small spatial scales, it can be used for estimating levels of metal pollution in biological material. This paper provides a preliminary report of a pilot study on the use of PIXE for the identification and quantification of elements (Al (3 wt%), Si 0.5 wt%), S (1.5 wt%), Cl (15 ppm), Mn (5 ppm), Fe (50 ppm), Ni (3 ppm), Zn (2 ppm), Rb (2 ppm), Sr (800 ppm) and Se (3 ppm)) in scales of the estuarine fish Pomadasys kaakan caught in the Matola River upstream from the Maputo estuary and, downstream of an aluminium smelter. Concentrations of both aluminium and sulphur were high (3 wt% and 1.5 wt%, respectively).

  13. Proton Induced X-Rays Emission (PIXE) and Atomic Absorption Spectrometry (AAS) applied in the environmental sample analysis

    International Nuclear Information System (INIS)

    Popescu, Ion V.; Iordan, M.; Stihi, C.; Bancuta, A.; Dima, G.; Busuioc, G.; Ciupina, V.; Belc, M.; Badica, T.

    2003-01-01

    The aim of this work is to determine the elemental composition of tree leaves using Proton-Induced X-Rays Emission (PIXE) and Atomic Absorption Spectrophotometry (AAS) methods. By PIXE Spectrometry we identified and determined the concentration of S, Cl, K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu Zn, As, Br, Sr and by AAS method the concentration of elements: Cr, Mn, Fe, Co, Cu, Zn, Se, Cd. Pb was identified in only 2 samples from 29. For tree leave samples collected at a large distance to the polluting source the Sr concentration decreased and the Mg, Ca, Se, Zn and Fe concentrations increased. Also, we can observe a small affinity of these leaves for the environmental Pb which was detected for two samples at a small distance to polluting source. (authors)

  14. Identification of urushi coated films taken from ancient Buddha images by using PIXE, FT-IR, and organic elemental analysis

    International Nuclear Information System (INIS)

    Kagemori, N.; Umemura, K.; Yoshimura, T.; Inoue, M.; Kawai, S.; Yano, K.; Sera, K.; Futatsugawa, S.; Nakamura, Y.

    1999-01-01

    Six types of samples including urushi, urushi tree and black coating films taken from ancient Buddha images were examined by analyses of PIXE, organic element and FT-IR to identify with urushi or another material. Based on the results of three analytical experiments above mentioned, the coating materials aging over hundreds of years were identified with weathered urushi films mixed with other material. Further investigation may reveal the urushi coating techniques used in the past. (author)

  15. Proton Induced X-Ray Emission (PIXE) Analysis to Measure Trace Metals in Soil Along the East River in Queens, New York

    Science.gov (United States)

    Chalise, Sajju; Conlan, Skye; Porat, Zachary; Labrake, Scott; Vineyard, Michael

    2017-09-01

    The Union College Ion-Beam Analysis Lab's 1.1 MV tandem Pelletron accelerator is used to determine the presence of heavy trace metals in Queens, NY between Astoria Park and 3.5 miles south to Gantry State Park. A PIXE analysis was performed on 0.5 g pelletized soil samples with a 2.2 MeV proton beam. The results show the presence of elements ranging from Ti to Pb with the concentration of Pb in Astoria Park (2200 +/-200 ppm) approximately ten times that of the Gantry State Park. We hypothesize that the high lead concentration at Astoria Park is due to the nearby Hell Gate Bridge, painted in 1916 with lead based paint, then sandblasted and repainted in the '90s. If the lead is from the repair of the bridge, then we should see the concentration decrease as we go further from the bridge. To test this, soil samples were collected and analyzed from seven different locations north and south of the bridge. The concentrations of lead decreased drastically within a 500 m radius and were approximately constant at greater distances. More soil samples need to be collected within the 500 m radius from bridge to identify the potential source of Pb. We will describe the experimental procedure, the PIXE analysis of soil samples, and present preliminary results on the distribution of heavy trace metals.

  16. Analysis of Atmospheric Aerosols Collected in an Urban Area in Upstate NY Using Proton Induced X-ray Emission (PIXE) Spectroscopy

    Science.gov (United States)

    Smith, Jeremy; Ali, Salina; Nadareski, Benjamin; Safiq, Alexandrea; Yoskowitz, Joshua; Labrake, Scott; Vineyard, Michael

    2013-10-01

    We examined atmospheric aerosol samples collected in Schenectady NY for evidence of pollution. We collected aerosol samples using a nine stage cascade impactor which distributes the particulate matter by aerodynamic size onto 7.5 μm Kapton foils. We then used a 1MV electrostatic Pelletron accelerator to produce a 2.2 MeV proton beam to hit the impacted foils. X-ray intensity versus energy spectra were collected using an Amptek x-ray detector where the x-rays are produced from the proton beam interacting with the sample. This is called PIXE. The elemental composition and concentrations of the elements present in the aerosol samples were determined using a software package called GUPIX. We have found elements ranging from Al to Pb and in particular have found significant amounts of Pb and Br on some of our impacted foils, with a Br/Pb ratio of 0.6 +/- 0.2 which agrees with previous studies. This result suggests the presence of leaded aviation fuel perhaps due to the proximity of the collection site to a small airport with a significant amount of general aviation traffic. Union College.

  17. Cluster cosmological analysis with X ray instrumental observables: introduction and testing of AsPIX method

    International Nuclear Information System (INIS)

    Valotti, Andrea

    2016-01-01

    Cosmology is one of the fundamental pillars of astrophysics, as such it contains many unsolved puzzles. To investigate some of those puzzles, we analyze X-ray surveys of galaxy clusters. These surveys are possible thanks to the bremsstrahlung emission of the intra-cluster medium. The simultaneous fit of cluster counts as a function of mass and distance provides an independent measure of cosmological parameters such as Ω m , σ s , and the dark energy equation of state w0. A novel approach to cosmological analysis using galaxy cluster data, called top-down, was developed in N. Clerc et al. (2012). This top-down approach is based purely on instrumental observables that are considered in a two-dimensional X-ray color-magnitude diagram. The method self-consistently includes selection effects and scaling relationships. It also provides a means of bypassing the computation of individual cluster masses. My work presents an extension of the top-down method by introducing the apparent size of the cluster, creating a three-dimensional X-ray cluster diagram. The size of a cluster is sensitive to both the cluster mass and its angular diameter, so it must also be included in the assessment of selection effects. The performance of this new method is investigated using a Fisher analysis. In parallel, I have studied the effects of the intrinsic scatter in the cluster size scaling relation on the sample selection as well as on the obtained cosmological parameters. To validate the method, I estimate uncertainties of cosmological parameters with MCMC method Amoeba minimization routine and using two simulated XMM surveys that have an increasing level of complexity. The first simulated survey is a set of toy catalogues of 100 and 10000 deg 2 , whereas the second is a 1000 deg 2 catalogue that was generated using an Aardvark semi-analytical N-body simulation. This comparison corroborates the conclusions of the Fisher analysis. In conclusion, I find that a cluster diagram that accounts

  18. Trace elemental analysis of carcinoma kidney and stomach by PIXE method

    International Nuclear Information System (INIS)

    Reddy, S. Bhuloka; John Charles, M.; Naga Raju, G.J.; Vijayan, V.; Seetharami Reddy, B.; Ravi Kumar, M.; Sundareswar, B.

    2003-01-01

    Trace elemental analysis was carried out in the biological samples of carcinoma kidney and stomach using particle induced X-ray emission technique. A 2 MeV proton beam was employed to excite the samples. From the present results, the levels of elements K, Ca, Fe, Ni and Se are lower and those of the elements Ti, Co, Zn, As and Cd are higher in the cancer tissue of kidney than those observed in the normal tissue. In the case of stomach, the concentrations of elements Cl, K, Ca, Ti, Mn, Fe, Co, Cu and Zn are lower while concentrations of elements Cr, Ni, As and Br are higher in the cancer tissue of stomach than those observed in the normal tissue. The observed deficiency or excess of certain elements is correlated to carcinogenesis of that organ. The present results of carcinoma stomach support the previous observations that nickel and chromium are carcinogenic agents. The low levels of selenium observed in the carcinoma tissue of kidney and the low levels of manganese observed in the carcinoma tissue of stomach support the view that selenium and manganese inhibit the growth of cancer in kidney and stomach respectively. The observed high levels of zinc in the cancer tissue of kidney suggest that zinc is involved in the tumor growth and development of neoplastic transformation in kidney while the observed low levels of zinc in the carcinoma tissue of stomach suggest that zinc inhibits the growth of cancer in this organ. For correctly assessing the role played by the trace elements in initiating, promoting or inhibiting cancer in various organs, there is a need for acquisition of more data by trace elemental analysis from several investigations of this type undertaken in different regions

  19. Timepix and FitPix detection system for RBS/C materials analysis

    CERN Document Server

    David-Bosne, Eric; Wahl, Ulrich

    This thesis reports the implementation of a Timepix position sensitive detector in a ion beam facility with a 0.5 mm collimated beam of 2MeV 1H$^{+}$ and 4He$^{+}$ for use in Rutherford Back-scattering Spectrometry channeling (RBS/C). A complete description is given of the methodology used for energy calibration, RBS data analysis and simulation with the FLUX Monte Carlo simulation program. Energy calibration was performed with internal test pulses and resulting resolution and accuracy were verified in two ways. The first time using a triple alpha source with the isotopes $^{239}$Pu, $^{241}$Am and $^{244}$Cm and secondly using a RBS spectrum of a thin film sample of Au/SiO$_{2}$/C. Setup characterization for channeling measurements was performed using single crystals of Si, 6H$^{-}$SiC and SrTiO$_{3}$. An energy resolution of 47.2 keV at 1862 keV for He$^{+}$ and an angular resolution of 0.11 (standard deviation) was achieved. Count rates as high as 2kHz were achieved with a frame rate of 15 frames/s. Higher...

  20. A PIXE analysis for measuring the trace elements concentration in breast tissue of Iranian women

    International Nuclear Information System (INIS)

    Vatankhah, S.; Moosavi, K.; Salimi, J.; Geranpayeh, L.; Perovani, H.

    2003-01-01

    A powerful and improved technique, proton induced x-ray emission has been performed-yielding the elemental composition of 17 samples of surgically excised malignant and normal tumors of breast tissue. The samples without any further process as thick targets were put on cap ton foil backing. There are no homogenizing processes. The proton induced x-ray emission spectra analysis was performed using he non-linear least square fitting code AXIL and GUPIX. The samples are taken form patients in the wide range of age and are bombarded by 2.0 MeV energy proton beams produced by van de Graaff accelerator in vacuum. The quantitative comparison between two of tissue was evaluated by assessing the presence of calcium. Potassium, Iron, Copper and Zinc, as minor and trace elements. results in this study indicate that relative values of Cu/Zn, P/K and also Ca and S in being type were higher than those in those in malignant type, but the concentration of Fe and Zn in cancerous tissues was significantly higher than those for being type. Results suggest significant elevation of zinc in the pathological tissues. Cu/Zn ratio for both type of tissues are evaluated. The results show that this ratio in patients with breast cancer is significantly lower than the normal group. Selenium and arsenic was not obtained in any of 17 samples. Most of the tissues of benign kind (fibrocystic and fib ro adenoma)contain cadmium. Calcium concentration in normal tissues is significantly higher than tumorous tissues

  1. miniPixD : a compact sample analysis system which combines X-ray imaging and diffraction

    International Nuclear Information System (INIS)

    Moss, Robert; Crews, Chiaki; Speller, Robert; Wilson, Matthew

    2017-01-01

    This paper introduces miniPixD : a new, compact system that utilises transmission X-ray imaging and X-ray diffraction (XRD) to locate and identify materials of interest within an otherwise opaque volume. The system and the embodied techniques have utility in security screening, medical diagnostics, non-destructive testing (NDT) and quality assurance (QA). This paper outlines the design of the system including discussion on the choice of components and presents some data from relevant samples which are compared to other energy dispersive and angular dispersive XRD techniques.

  2. Nuclear techniques (PIXE and RBS) applied to analysis of pre hispanic metals of the Templo Mayor at Tenochtitlan

    International Nuclear Information System (INIS)

    Mendez U, I.; Tenorio, D.; Galvan, J.L.

    2000-01-01

    This work has the objective of determining by means of the utilization of nuclear techniques (PIXE and RBS) the composition and the alloy type of diverse aztec ornaments corresponding to Post classic period, they were manufactured principally with copper and gold such as bells, beads and disks; all they belonging at 9 oblations of Templo Mayor of Tenochtitlan. It is presented here briefly the historical and archaeological antecedents of the devices as well as the analytical methods for conclude with the results obtained. (Author)

  3. PIXE study on the provenance of Chinese ancient porcelain

    International Nuclear Information System (INIS)

    Zhu, D.; Cheng, H.S.; Lin, J.W.; Yang, F.J.

    2006-01-01

    This paper reports the PIXE study on the provenance of Chinese ancient porcelain made in 7-10th century. The chemical compositions of Jun celadon samples made at Juntai, Linru and Hunyuan kilns, the white-glazed porcelain samples made at Ding, Huangye and Dangyangyu kilns, and the Ru celadon samples made at Qiangliang Temple were measured by external-beam PIXE, and the factor analysis was applied for identifying their provenances. Experimental results show that the porcelain products made at different kilns can be distinguished according to the compositional differences measured by PIXE

  4. PIXE study on the provenance of Chinese ancient porcelain

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, D. [Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433 (China); Cheng, H.S. [Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433 (China)]. E-mail: hscheng@fudan.edu.cn; Lin, J.W. [Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433 (China); Yang, F.J. [Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433 (China)

    2006-08-15

    This paper reports the PIXE study on the provenance of Chinese ancient porcelain made in 7-10th century. The chemical compositions of Jun celadon samples made at Juntai, Linru and Hunyuan kilns, the white-glazed porcelain samples made at Ding, Huangye and Dangyangyu kilns, and the Ru celadon samples made at Qiangliang Temple were measured by external-beam PIXE, and the factor analysis was applied for identifying their provenances. Experimental results show that the porcelain products made at different kilns can be distinguished according to the compositional differences measured by PIXE.

  5. PIXE study on the provenance of Chinese ancient porcelain

    Science.gov (United States)

    Zhu, D.; Cheng, H. S.; Lin, J. W.; Yang, F. J.

    2006-08-01

    This paper reports the PIXE study on the provenance of Chinese ancient porcelain made in 7-10th century. The chemical compositions of Jun celadon samples made at Juntai, Linru and Hunyuan kilns, the white-glazed porcelain samples made at Ding, Huangye and Dangyangyu kilns, and the Ru celadon samples made at Qiangliang Temple were measured by external-beam PIXE, and the factor analysis was applied for identifying their provenances. Experimental results show that the porcelain products made at different kilns can be distinguished according to the compositional differences measured by PIXE.

  6. PIXE applications to the toxicological field

    Energy Technology Data Exchange (ETDEWEB)

    Santos, C.E.I. dos; Dias, J.F.; Jobim, P.F.C.; Yoneama, M.L. [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Instituto de Fisica. Laboratorio de Implantacao Ionica; Andrade, V.M. [Universidade do Extremo Sul Catarinense, Criciuma, SC (Brazil). Laboratorio de Biologia Celular e Molecular; Amaral, L.; Silva, J. da [Universidade Luterana do Brasil, Canoas, RS (Brazil). Laboratorio de Toxicologia Generica

    2013-07-01

    Full text: Several studies have been carried out in order to investigate the toxicological properties of some chemical elements in different type of biological samples. lon beam techniques, in particular PIXE, have been successfully used to analyze the elemental composition of food, beverage, plants and animal tissues. In this context, the PIXE line of the lon Implantation Laboratory (Porto Alegre, Brazil) have been used in the last few years to study food and beverage processing and biological specimens exposed to contaminated environment. The aim of this study is to present some of our results using PIXE analysis applied to toxicological research field. For instance, a recent published research [1] investigated the genotoxic and mutagenic effects in tobacco farmers exposed to metal-based formulated pesticides. Levels of Mg, AI, CI, Zn, Cr and Br, elements associated with DNA damage, were higher in the blood samples of tobacco farmers exposed to pesticide than in the non-exposed group. The occupational genotoxicity among copper smelters was also investigated [2]. The elemental content of blood samples were analyzed by PIXE. DNA damage in the peripheral blood Iymphocytes of workers exposed to copper smelter was observed. However, no clear correlation was found between the metal content and DNA damage. [1] F. R. da Silva, J. da Silva, M. C. AlIgayer, C. F. Simon, J. F. Dias, C. E. I. dos Santos, M. Salvador, C. Branco, N. B. Schneider, V. Kahl, P. Rohr, K. Kvitko, J. Hazard. Mat., 225-226 (2012) 81-90. (author)

  7. PIXE applications to the toxicological field

    International Nuclear Information System (INIS)

    Santos, C.E.I. dos; Dias, J.F.; Jobim, P.F.C.; Yoneama, M.L.; Andrade, V.M.; Amaral, L.; Silva, J. da

    2013-01-01

    Full text: Several studies have been carried out in order to investigate the toxicological properties of some chemical elements in different type of biological samples. lon beam techniques, in particular PIXE, have been successfully used to analyze the elemental composition of food, beverage, plants and animal tissues. In this context, the PIXE line of the lon Implantation Laboratory (Porto Alegre, Brazil) have been used in the last few years to study food and beverage processing and biological specimens exposed to contaminated environment. The aim of this study is to present some of our results using PIXE analysis applied to toxicological research field. For instance, a recent published research [1] investigated the genotoxic and mutagenic effects in tobacco farmers exposed to metal-based formulated pesticides. Levels of Mg, AI, CI, Zn, Cr and Br, elements associated with DNA damage, were higher in the blood samples of tobacco farmers exposed to pesticide than in the non-exposed group. The occupational genotoxicity among copper smelters was also investigated [2]. The elemental content of blood samples were analyzed by PIXE. DNA damage in the peripheral blood Iymphocytes of workers exposed to copper smelter was observed. However, no clear correlation was found between the metal content and DNA damage. [1] F. R. da Silva, J. da Silva, M. C. AlIgayer, C. F. Simon, J. F. Dias, C. E. I. dos Santos, M. Salvador, C. Branco, N. B. Schneider, V. Kahl, P. Rohr, K. Kvitko, J. Hazard. Mat., 225-226 (2012) 81-90. (author)

  8. Fluorine analysis of human enamel around fluoride-containing materials under different pH-cycling by μ-PIGE/PIXE system

    International Nuclear Information System (INIS)

    Komatsu, H.; Yamamoto, H.; Matsuda, Y.; Kijimura, T.; Kinugawa, M.; Okuyama, K.; Nomachi, M.; Yasuda, K.; Satoh, T.; Oikawa, S.

    2011-01-01

    The caries preventive effect of fluoride-containing materials (FCMs) might depend on the caries risk of the individuals. Two pairs of demineralizing and remineralizing solutions of pH-cycling were prepared for simulating low and high caries risk. The purpose of this study was to determine fluorine (F) uptake into human enamel around FCMs under different pH-cycling using the in-air μ-PIGE/PIXE system. Fluoride-containing glass ionomer cement (Fuji IX GP FAST CAPSULE (FN)), and composite resin (BEAUTIFIL II with FLUORO BOND SHAKE ONE (BS)) were used in this study. The pH-cycling (pH 6.8-4.5) was carried out for 5 weeks. After pH-cycling, the caries progression was analyzed using transverse micro-radiography (TMR). The fluorine and calcium distributions in the carious lesion in each specimen were evaluated using the PIGE/PIXE system. From TMR analysis, there was a difference in caries risk between the two kinds of pH-cycling. Although the caries preventive effect of BS and FN was confirmed at low risk, the effect at high risk was confirmed for FN only. From the analysis of the fluorine uptake in the outer 200 μm of the lesion we concluded that there was no significant difference between the pH-cycling solutions. However, we found different fluorine concentrations in the enamel for the two FCMs. The decreased caries progression under high risk for FN indicated that an adequate amount of fluorine supplied from the material is required at higher caries risk. It was confirmed that the caries preventive effect of FCM depends on the caries risk. The fluorine analysis of teeth under various pH-cycling conditions gives information to evaluate the caries preventive effect of fluoride-containing materials according to the caries risk.

  9. Fluorine analysis of human enamel around fluoride-containing materials under different pH-cycling by {mu}-PIGE/PIXE system

    Energy Technology Data Exchange (ETDEWEB)

    Komatsu, H., E-mail: kom@den.hokudai.ac.jp [Graduate School of Dental Medicine, Hokkaido University, Kita-13, Nishi-7, Kita-ku, Sapporo 060-8586 (Japan); Yamamoto, H. [Graduate School of Dentistry, Osaka University, 1-8 Yamada-Oka, Suita 565-0871 (Japan); Matsuda, Y.; Kijimura, T.; Kinugawa, M.; Okuyama, K. [Graduate School of Dental Medicine, Hokkaido University, Kita-13, Nishi-7, Kita-ku, Sapporo 060-8586 (Japan); Nomachi, M. [Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka 560-0043 (Japan); Yasuda, K. [Wakasa Wan Energy Research Center, 64-52-1 Hase, Tsuruga 914-0192 (Japan); Satoh, T. [Advanced Radiation Technology, TARRI, JAEA, 1233 Watanuki-Machi, Takasaki 370-1292 (Japan); Oikawa, S. [National Institute of Radiological Science, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2011-10-15

    The caries preventive effect of fluoride-containing materials (FCMs) might depend on the caries risk of the individuals. Two pairs of demineralizing and remineralizing solutions of pH-cycling were prepared for simulating low and high caries risk. The purpose of this study was to determine fluorine (F) uptake into human enamel around FCMs under different pH-cycling using the in-air {mu}-PIGE/PIXE system. Fluoride-containing glass ionomer cement (Fuji IX{sub GP} FAST CAPSULE (FN)), and composite resin (BEAUTIFIL II with FLUORO BOND SHAKE ONE (BS)) were used in this study. The pH-cycling (pH 6.8-4.5) was carried out for 5 weeks. After pH-cycling, the caries progression was analyzed using transverse micro-radiography (TMR). The fluorine and calcium distributions in the carious lesion in each specimen were evaluated using the PIGE/PIXE system. From TMR analysis, there was a difference in caries risk between the two kinds of pH-cycling. Although the caries preventive effect of BS and FN was confirmed at low risk, the effect at high risk was confirmed for FN only. From the analysis of the fluorine uptake in the outer 200 {mu}m of the lesion we concluded that there was no significant difference between the pH-cycling solutions. However, we found different fluorine concentrations in the enamel for the two FCMs. The decreased caries progression under high risk for FN indicated that an adequate amount of fluorine supplied from the material is required at higher caries risk. It was confirmed that the caries preventive effect of FCM depends on the caries risk. The fluorine analysis of teeth under various pH-cycling conditions gives information to evaluate the caries preventive effect of fluoride-containing materials according to the caries risk.

  10. Determination of metal balance shift induced in small fresh water fish by X-ray irradiation using PIXE analysis

    International Nuclear Information System (INIS)

    Yukawa, M.; Aoki, K.; Iso, H.; Kodama, K.; Imaseki, H.; Ishikawa, Y.

    2005-01-01

    In the environmental pollution studies, it is very important to detect not only pollutants but also changes induced in organisms in the environment with various environmental stresses such as heavy metal toxicity radiation and agricultural chemicals. In the latter, monitoring is carried out using biological indicators to find out the changes, which have wide spectra from visible like deformity of the body to invisible such as changes in some enzyme activities. Changes of the balance of essential elements could occur in organisms to deal with the stresses. If we detect an elemental balance shift, we may see the environmental pollution in its early stages. Moreover, in the actual environment, combined effects, additive or reductive with coexistent elements or other stresses, is an important subject for investigation. Therefore, measurement of many elements in the biological indicator's simultaneously and determination of the distribution in the organisms are useful in clarifying the action of pollutants at sublethal levels. A small fresh water fish, Medaka can be used as one of the biological-indicators for determination of water quality. In the National Institute of Radiological Sciences (NIRS), an inbred strain of Medaka Orizias laptipes was established and has been maintained for the research purposes. Since the genetic background of inbred animals is almost uniform, the individual deviation among animals is very small. This characteristic is very useful to investigate the physiological effects of environmental stresses. We have continued to investigate the balance shift of essential elements induced in the bodies of Medaka by several stresses. In this paper, elemental content in various organs of the X-ray irradiated fish determined by PIXE method are reported in comparison with that of the control fish to observe the effect of the X-rays. Body size of Medaka is about 3 cm long, and the internal organs are very small (about l mm on average). PIXE is the most

  11. Coherent betatron instability driven by electrostatic separators: Stability analysis of the Tevatron

    International Nuclear Information System (INIS)

    Harfoush, F.A.; Bogacz, S.A.

    1989-03-01

    This paper outlines possible intensity limits due to the coherent betatron motion for the upgraded Tevatron with the electrostatic separators. Numerical simulation shows that this new vacuum chamber structure dominates the high frequency part of the coupling impedance spectrum and more likely will excite a slow head-tail instability. A simple stability analysis yields the characteristic growth-time of the unstable modes. 4 refs., 4 figs., 1 tab

  12. Determination of chromium(VI) in water by PIXE analysis using ion exchange paper. Limit of detection and interference by coexisting anions

    International Nuclear Information System (INIS)

    Thomyasirigul, Sureerat; Fukuda, Hitoshi; Hasegawa, Jun; Oguri, Yoshiyuki

    2009-01-01

    Concerning the PIXE analysis of Cr(VI) in water using ion-exchange filters, the limit of detection (LOD) and the influence of matrix anions were investigated. In order to look for the experimental condition for obtaining the minimum LOD, we measured the Cr-Kα X-ray counts and background counts under the Kα X-ray peak as a function of the incident proton energy and the thickness of the Mylar absorber foil in front of the detector. To investigate the interference by coexisting anions, each of PO 4 3- , SO 4 2- , NO 3 - , Cl - , and F - ions and Cr(VI) ions were mixed in aqueous solutions and adsorbed on DE81-DEAE cellulose paper, a weakly basic anion exchanger with diethylaminoethyl functional groups. Then the filter samples were measured by PIXE using 2.5 MeV proton beams. We obtained a LOD of 0.16 μg or 8 ppb for 20 mL samples at a proton energy of 2.5 MeV and a Mylar film thickness of 50 or 100 μm. The experimental results on the mixed solutions indicated that NO 3 - , Cl - , and F - as coexisting ions didn't interfere significantly with determination of a 50 μg/L Cr(VI) concentration for 40 mL total solution volume, despite the total amount of anions was about 90% of ion exchange capacity of a filter. On the other hand, slight interferences by PO 4 3- ions were observed. However, under the same condition, we found that if the total amount of SO 4 2- ions was higher than 20% of ion exchange capacity, they induced significant interferences in determining Cr(VI). (author)

  13. An electrostatic plunger device and the analysis of recoil-distance spectra

    International Nuclear Information System (INIS)

    Marchie van Voorthuysen, E.H. du; Smith, Ph.B.

    1975-01-01

    In the electrostatic plunger apparatus, a large stopper foil is drawn towards the target electrostatically. The attracting field is controlled in a feedback loop by the capacity, so that the distance is stabilized during the measurement. Formulae for line-shape analysis of γ-ray spectra from recoil-distance lifetime measurements (RDM) are given. A measurement of the life-time of the 1759 keV level in 26 Al is reported yielding (3.4+-0.6)ps, in agreement with results from Doppler-shift attenuation, but in disagreement with other RDM results. In addition, accurate stopping-power measurements are reported for 2-9MeV alpha particles in Al, Ni, Cu, Au and Mylar. (Auth.)

  14. Nuclear techniques (PIXE and RBS) applied to analysis of pre hispanic metals of the Templo Mayor at Tenochtitlan; Tecnicas nucleares (PIXE y RBS) aplicadas al analisis de metales prehispanicos del Templo Mayor de Tenochtitlan

    Energy Technology Data Exchange (ETDEWEB)

    Mendez U, I.; Tenorio, D.; Galvan, J.L. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    This work has the objective of determining by means of the utilization of nuclear techniques (PIXE and RBS) the composition and the alloy type of diverse aztec ornaments corresponding to Post classic period, they were manufactured principally with copper and gold such as bells, beads and disks; all they belonging at 9 oblations of Templo Mayor of Tenochtitlan. It is presented here briefly the historical and archaeological antecedents of the devices as well as the analytical methods for conclude with the results obtained. (Author)

  15. Analysis of fast boundary-integral approximations for modeling electrostatic contributions of molecular binding

    Science.gov (United States)

    Kreienkamp, Amelia B.; Liu, Lucy Y.; Minkara, Mona S.; Knepley, Matthew G.; Bardhan, Jaydeep P.; Radhakrishnan, Mala L.

    2013-01-01

    We analyze and suggest improvements to a recently developed approximate continuum-electrostatic model for proteins. The model, called BIBEE/I (boundary-integral based electrostatics estimation with interpolation), was able to estimate electrostatic solvation free energies to within a mean unsigned error of 4% on a test set of more than 600 proteins—a significant improvement over previous BIBEE models. In this work, we tested the BIBEE/I model for its capability to predict residue-by-residue interactions in protein–protein binding, using the widely studied model system of trypsin and bovine pancreatic trypsin inhibitor (BPTI). Finding that the BIBEE/I model performs surprisingly less well in this task than simpler BIBEE models, we seek to explain this behavior in terms of the models’ differing spectral approximations of the exact boundary-integral operator. Calculations of analytically solvable systems (spheres and tri-axial ellipsoids) suggest two possibilities for improvement. The first is a modified BIBEE/I approach that captures the asymptotic eigenvalue limit correctly, and the second involves the dipole and quadrupole modes for ellipsoidal approximations of protein geometries. Our analysis suggests that fast, rigorous approximate models derived from reduced-basis approximation of boundary-integral equations might reach unprecedented accuracy, if the dipole and quadrupole modes can be captured quickly for general shapes. PMID:24466561

  16. PIXE and XRF analysis of atmospheric aerosols from a site in the West area of Mexico City

    Energy Technology Data Exchange (ETDEWEB)

    Díaz, R.V.; López-Monroy, J. [Instituto Nacional de Investigaciones Nucleares, Centro Nuclear “Nabor Carrillo”, Autopista México-Toluca, Salazar, Edo. Mex. (Mexico); Miranda, J., E-mail: miranda@fisica.unam.mx [Instituto Nacional de Investigaciones Nucleares, Centro Nuclear “Nabor Carrillo”, Autopista México-Toluca, Salazar, Edo. Mex. (Mexico); Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, 01000 México, DF (Mexico); Espinosa, A.A. [Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, 01000 México, DF (Mexico)

    2014-01-01

    Due to geographical factors, most of the Metropolitan Area of Mexico City features, on average, similar heights above the sea level, climate, wind speed and direction, with very uniform pollution degrees in most of the frequently studied sites. A site with different characteristics, Cuajimalpa de Morelos, was studied. It is located to the West of the urban area at 2760 m above sea level, in contrast to other sites (2240 m). Here, the wind is mostly directed towards the center of the city. Then, the site should not be affected by pollutants from the Northern/Northeastern industrial zones, so lower aerosol concentrations are expected. In this work, the elemental composition of coarse (PM{sub 10-2.5}) and fine (PM{sub 2.5}) fractions of atmospheric aerosol samples collected in Cuajimalpa is studied. The sampling period covered the cold-dry season in 2004–2005 (December 1st, 2004 to March 31, 2005), exposing polycarbonate filters with a Stacked Filter Unit of the Gent design along 24 h, every two days. The samples were analyzed with Particle Induced X-ray Emission (PIXE) and X-ray Fluorescence (XRF), to obtain elemental concentrations. The EPA code UNMIX was used to determine the number of possible influencing polluting sources, which were then identified through back-trajectory simulations with the HYSPLIT modeling software. Four sources (mostly related to soil) were found in the coarse fraction, while the fine fraction presented three main sources (fuel oil, industry and biomass burning)

  17. Use of micro-PIXE analysis for the identification of contaminants in the metal deposition on a CMS pitch adapter

    CERN Document Server

    Massi, M; Fedi, M E; Arilli, C; Grassi, N; Mando, P A; Migliori, A; Focardi, E

    2004-01-01

    In the silicon tracker for the Compact Muon Solenoid experiment at the forthcoming Large Hadron Collider of CERN, each silicon sensor is connected to the front-end electronics by a pitch adapter, the structure of which consists of a fan of very thin chromium strips coated with a few microns aluminium deposition, on a glass support. The absence of contaminants in the depositions is of crucial importance for the electrical and mechanical reliability of the micro-bonding connections. The PIXE set-up of the Florence external micro-beam facility appeared to be suitable to analyse the metal deposition of an adapter, on which the micro-bonds had shown mechanical and electrical problems. Our measurements pointed out a significant copper contamination of the metal deposition on the faulty adapter, while no copper was detected in another one, which showed a correct behaviour at bonding. This suggests a possible role of Cu impurities in the encountered problems during micro-bonding.

  18. PIXE and XRF analysis of atmospheric aerosols from a site in the West area of Mexico City

    International Nuclear Information System (INIS)

    Díaz, R.V.; López-Monroy, J.; Miranda, J.; Espinosa, A.A.

    2014-01-01

    Due to geographical factors, most of the Metropolitan Area of Mexico City features, on average, similar heights above the sea level, climate, wind speed and direction, with very uniform pollution degrees in most of the frequently studied sites. A site with different characteristics, Cuajimalpa de Morelos, was studied. It is located to the West of the urban area at 2760 m above sea level, in contrast to other sites (2240 m). Here, the wind is mostly directed towards the center of the city. Then, the site should not be affected by pollutants from the Northern/Northeastern industrial zones, so lower aerosol concentrations are expected. In this work, the elemental composition of coarse (PM 10-2.5 ) and fine (PM 2.5 ) fractions of atmospheric aerosol samples collected in Cuajimalpa is studied. The sampling period covered the cold-dry season in 2004–2005 (December 1st, 2004 to March 31, 2005), exposing polycarbonate filters with a Stacked Filter Unit of the Gent design along 24 h, every two days. The samples were analyzed with Particle Induced X-ray Emission (PIXE) and X-ray Fluorescence (XRF), to obtain elemental concentrations. The EPA code UNMIX was used to determine the number of possible influencing polluting sources, which were then identified through back-trajectory simulations with the HYSPLIT modeling software. Four sources (mostly related to soil) were found in the coarse fraction, while the fine fraction presented three main sources (fuel oil, industry and biomass burning)

  19. Application of photoacoustic infrared spectroscopy and PIXE/PIGME tot he analysis and provenancing of inorganic pigments from an archaeological site

    International Nuclear Information System (INIS)

    Goodall, R.A.; Bartley, J.P.; David, B.

    1997-01-01

    As part of a larger study into the sources of ochre used by indigenous people in south eastern Cape York Peninsula, Australia, the ochres found in excavated deposits and paint samples from the stencils and painted panels in Fern Cave, near Chillagoe, were investigated. Previous work in the analysis of paints has identified the need to used non-destructive techniques and the necessity of taking samples of microgram quantities. When selecting the techniques for use in this study these factors were kept in mind. Fourier transform infrared photoacoustic spectroscopy (FTIR-PAS) was selected because it can be applied to samples of only a few micrograms and because it is completely non-destructive when necessary. To compliment and support the information obtained from the FTIR-PAS, elemental analysis was also carried out on the same samples using scanning electron microscopy with energy dispersive X-ray analysis (SEM-EDXA), proton induced x-ray and gamma ray emission (PIXE/PIGME). The spectra were obtained with little or no sample preparation and provided the structural and compositional information to identify the major and minor mineral present in both excavated and painted samples

  20. Representation of Muharram Rituals in West Media; Semiotic Analysis of TotallyCoolPix Website’s Photos of Muharam and Ashura

    Directory of Open Access Journals (Sweden)

    Majid Movahed Majd

    2015-12-01

    Full Text Available Protecting and upholding the ideology of media authorities, photo can be considered a tool for communication and meaning-making. Also the social-artistic activities of photograpy paly a significant role in communication as any other media does. The representation theory excessively concerned with media analysis. It should be noted that semiotic method gives the ability to examine hidden layers of media contents such as picture. Based on The representation theory and semiotics techniques, this paper involves in analyzing photography which represented in TotallyCoolPix Website with Theme of Muharam and Ashura (the 10th day of Muharram in the Islamic calendar.  The outcomes of this analysis reveal that these photos represent Islam and Muslims as “other”, and also including a kind of deviation from the true Muharram rituals among Muslims. This set of pictures can be characterized by some features such as violence, masculinity, passive role of women in religious customs, cohesiveness and collective strength, which are become prevalent in Muslim communities. What is more, traditional Shiite symbols hinged upon these features and themes in these pictures. Overall, the concepts obtained from these pictures analysis illustrate that they are brimmed with violence which pave the way for more Islam- phobia in countries in the Occident.

  1. Application of photoacoustic infrared spectroscopy and PIXE/PIGME tot he analysis and provenancing of inorganic pigments from an archaeological site.

    Energy Technology Data Exchange (ETDEWEB)

    Goodall, R.A.; Bartley, J.P. [Queensland Univ., St. Lucia, QLD (Australia). Dept. of Chemistry; David, B. [Queensland Univ., St. Lucia, QLD (Australia). Dept. of Anthropology and Sociology

    1997-12-31

    As part of a larger study into the sources of ochre used by indigenous people in south eastern Cape York Peninsula, Australia, the ochres found in excavated deposits and paint samples from the stencils and painted panels in Fern Cave, near Chillagoe, were investigated. Previous work in the analysis of paints has identified the need to used non-destructive techniques and the necessity of taking samples of microgram quantities. When selecting the techniques for use in this study these factors were kept in mind. Fourier transform infrared photoacoustic spectroscopy (FTIR-PAS) was selected because it can be applied to samples of only a few micrograms and because it is completely non-destructive when necessary. To compliment and support the information obtained from the FTIR-PAS, elemental analysis was also carried out on the same samples using scanning electron microscopy with energy dispersive X-ray analysis (SEM-EDXA), proton induced x-ray and gamma ray emission (PIXE/PIGME). The spectra were obtained with little or no sample preparation and provided the structural and compositional information to identify the major and minor mineral present in both excavated and painted samples. Paper no. 65; Extended abstract. 8 refs.

  2. Homotopy Analysis Method for Nonlinear Dynamical System of an Electrostatically Actuated Microcantilever

    Directory of Open Access Journals (Sweden)

    Y. M. Chen

    2011-01-01

    Full Text Available The homotopy analysis method (HAM is employed to propose an approach for solving the nonlinear dynamical system of an electrostatically actuated micro-cantilever in MEMS. There are two relative merits of the presented HAM compared with some usual procedures of the HAM. First, a new auxiliary linear operator is constructed. This operator makes it unnecessary to eliminate any secular terms. Furthermore, all the deformation equations are purely linear. Numerical examples show the excellent agreement of the attained solutions with numerical ones. The respective effects of applied voltage, cubic nonlinear stiffness, gap distance, and squeeze film damping on vibration responses are analyzed detailedly.

  3. Portable XRF and PIXE as complementary techniques for the analysis of old books: study of decorated flyleaves and edges

    International Nuclear Information System (INIS)

    Torner M, L.; Gonzalez T, C.; Ruvalcaba S, J.L.

    2006-01-01

    Traditionally in the study of ancient books, the binding (leather, parchment, cloth) and their decorations have not the same importance than other parts of the book. Most of the times, paper, inks and internal decorations attract entirely the attention for analytical studies. Nevertheless, it must be considered that the binding keep the book safe and it may be exposed D higher deterioration. Moreover, often it is changed and the historical value of this part of the book is lost. his is also the case of binding's decorations. For these reasons, it is clear that he binding of ancient books must be studied as a part of their material essence. In this work, methodology based on t]he combined use of microscopic and elemental analyses was applied in order to study four types of decorations of guards of books (marbled, colored, splashed, dotted). In particular, this study was focused on Colonial and Mexican books from XVIII and XIX centuries from the collection of the Biblioteca Nacional de Antropologia e Historia, lNAH. Twelve books and 62 decoration's colors were analyzed in situ, in the library, using a portable X-ray Fluorescence Spectroscopy system (XRF) for a quick nondestructive pigment identification and to select a reduced number of books for complementary analyses at the laboratory by Particle Induced X-ray Emission Spectroscopy (PIXE). By combining these nondestructive techniques, it was possible to identify most of the pigments used in the decorations and to establish a general pattern of use of colorants and pigments in XVIII and XIX centuries for the guard's decorations. This work represents the first study on this topic. (Author)

  4. PIXE and its applications to biological samples

    International Nuclear Information System (INIS)

    Aldape, F.; Flores, M.J.

    1996-01-01

    Throughout this century, industrialized society has seriously affected the ecology by introducing huge amounts of pollutants into the atmosphere as well as marine and soil environments. On the other hand, it is known that these pollutants, in excess of certain levels of concentration, not only put at risk the life of living beings but may also cause the extinction of some species. It is therefore of basic importance to substantially increase quantitative determinations of trace element concentrations in biological specimens in order to assess the effects of pollutants. It is in this field that PIXE plays a key role in these studies, where its unique analytical properties are decisive. Moreover, since the importance of these research has been recognized in many countries, many scientists have been encouraged to continue or initiate new research programmes aimed to solve the worldwide pollution problem. This document presents an overview of those papers reporting the application of PIXE analysis to biological samples during this last decade of the 20th century and recounts the number of PIXE laboratories dedicating their efforts to find the clues of the biological effects of the presence of pollutants introduced in living beings. Sample preparation methods, different kinds of samples under study and the use of complementary analytical techniques are also illustrated. (author). 108 refs

  5. High energy proton PIXE [HEPP

    International Nuclear Information System (INIS)

    McKee, J.S.C.

    1993-01-01

    Studies of particle induced X-ray emission (PIXE) have been widespread and detailed in recent years and despite the fact that most data obtained are from low energy 1-3 MeV experiments, the value of higher energy proton work with its emphasis on K X-ray emission has become more marked as time has progressed. The purpose of this review paper is to outline the history of analysis using high energy protons and to compare and contrast the results obtained with those from lower energy analysis using more firmly established analytical techniques. The work described will concentrate exclusively on proton induced processes and will attempt to outline the rationale for selecting an energy, greater than 20 and up to 70 MeV protons for initiating particles. The relative ease and accuracy of the measurements obtained will be addressed. Clearly such X-ray studies should be seen as complementing low energy work in many instances rather than competing directly with them. However, it will be demonstrated that above a Z value of approximately 20, K X-ray analysis using high energy protons is the only way to go in this type of analysis. (author)

  6. The Byzantine ceramics from Pergamon excavations. Characterization of local and imported productions by elementary analysis using PIXE and INAA methods and by petrography

    International Nuclear Information System (INIS)

    Waksman, S.Y.

    1995-01-01

    An important ceramics material dated back to the 12th-14th centuries has been excavated in Pergamon (Turkey). Among these findings, wasters, tripod stilts and unfinished ware attest to local production in the Byzantine period. Elemental analysis by the methods PIXE (Particle Induced X-ray Emission) and INAA (Instrumental Neutron Activation Analysis) has been performed on a representative sampling of 160 sherds, including attested local material. Multivariate statistical techniques were used to classify the sherds into groups of similar composition and thus to distinguish ceramics made in Pergamon from imported wares. Several groups of local production have been constituted, which correspond to wares differing in date and fabric. The geochemical characterization of the pastes, complemented with petrographical and mineralogical data, shows that specific raw materials have been used to manufacture each ware. The analytical data related to ceramics made in Pergamon will serve as reference data for future provenance studies. Such reference groups of Byzantine ceramics are very rare, and therefore the ceramics imported into Pergamon cannot be attributed as to their origin. Among the ceramics widely diffused in the Byzantine world, some importations belonging to the ''fine sgraffito'' and ''Zeuxippus ware'' types have been identified. The latter type has been a source of stylistic influence for the workshops of Pergamon, since the analyses show that imitated ''Zeuxippus ware'' has been produced there. These imitations were probably themselves diffused on a regional scale. (author). 238 refs., 48 figs., 53 tabs., 22 photos., 8 appends

  7. Proton-induced X-ray emission (PIXE) spectrometry - state of the art

    International Nuclear Information System (INIS)

    Johansson, S.A.E.

    1986-01-01

    The development of the PIXE method for multielemental analysis is described. A brief account is given of the physical principles and the experimental arrangements. The use of PIXE is illustrated by a number of typical applications in geology, biology, medicine and environmental research. (orig.) [de

  8. PIXE and XRF analysis of atmospheric aerosols from a site in the West area of Mexico City

    International Nuclear Information System (INIS)

    Diaz, R.V.; López-Monroy, J.; Miranda, J.; Espinosa, A.A.

    2013-01-01

    Full text: The pollution by atmospheric aerosols in the Metropolitan Area of Mexico City (MAMC) is still presenting issues that require deeper studies. Because of geographical factors, most of the MAMC features, on average, very similar characteristics. These include height above the sea level, climate, wind speed and direction, resulting in very uniform pollution levels in most of the traditionally studied sites. A site with different characteristics with respect to them, Cuajimalpa de Morelos, was selected for the present work. It is located to the West of the MAMC at 2,760 m above sea level (a.s.l.), in contrast to other sites (2,240 m a.s.I); sub-humid area with lush vegetation, influenced by the forest of the 'Desierto de los Leones' National Park. Here, the wind for most part of the day is directed towards the center of the MAMC, joining flows that run from North to South. This prevents the site from receiving influence of pollutants generated in the Northern industrial zone, Xalostoc or Naucalpan. Thus, it is expected that this area should present lower concentration of pollutants than the rest of the MAMC. Therefore, the present work is aimed to study the elemental composition of coarse (PM 10- 2 .5 ) and fine (PM 2.5 ) fractions of atmospheric aerosol samples collected in Cuajimalpa. The sampling period covered the cold-dry season in 2004-2005 (December 1 st , 2004, to March 31, 2005), exposing polycarbonate filters with a Stacked Filter Unit (SFU) of the Gent design along 24 h, every two days. The samples were then analyzed with PIXE and X-ray Fluorescence (XRF), to obtain elemental concentrations. The EPA code UNMIX was used to determine the number of possible influencing polluting sources, which were then identified through back-trajectory simulations with the HYSPLlT modeling software. Four sources (mostly related to soil) were found for the coarse fraction, while the fine fraction presented three main sources (fuel oil, industry, and biomass

  9. Preliminary application of tapered glass capillary microbeam in MeV-PIXE mapping of longan leaf for elemental concentration distribution analysis

    Science.gov (United States)

    Natyanun, S.; Unai, S.; Yu, L. D.; Tippawan, U.; Pussadee, N.

    2017-09-01

    This study was aimed at understanding elemental concentration distribution in local longan leaf for how the plant was affected by the environment or agricultural operation. The analysis applied the MeV-microbeam particle induced X-ray emission (PIXE) mapping technique using a home-developed tapered glass capillary microbeam system at Chiang Mai University. The microbeam was 2-MeV proton beam in 130 µm in diameter. The studying interest was in the difference in the elemental concentrations distributed between the leaf midrib and lamina areas. The micro proton beam analyzed the leaf sample across the leaf midrib edge to the leaf lamina area for total 9 data requisition spots. The resulting data were colored to form a 1D-map of the elemental concentration distribution. Seven dominant elements, Al, S, Cl, K, Ca, Sc and Fe, were identified, the first six of which were found having higher concentrations in the midrib area than in the lamina area, while the Fe concentration was in an opposite trend to that of the others.

  10. PIXE as an analytical/educational tool

    International Nuclear Information System (INIS)

    Williams, E.T.

    1991-01-01

    The advantages and disadvantages of PIXE as an analytical method will be summarized. The authors will also discuss the advantages of PIXE as a means of providing interesting and feasible research projects for undergraduate science students

  11. PIXE application to the study of atmospheric aerosol

    International Nuclear Information System (INIS)

    Zhu Guanghua

    1998-11-01

    In order to confirm the measurement accuracy of PIXE (Particle Induced X-ray Emission), cross-check test were carried out between three laboratories. Thirty single element samples and one plural elements sample were used in the test. The agreements between three laboratories were evaluated to be better than 10% for the most of tested samples. The reproducibility test showed very good agreement and the dispersion in three times repeated PIXE measurements was within 6% on average. Using an automatic time sequence step sampler in Beijing collected atmospheric aerosol samples. Element concentrations were analyzed by PIXE technique. Then the data were analyzed by the absolute principal factor analysis (APFA) to evaluate the principal components and the percent variance explained by them. As a result, it shows that the PIXE analysis combed with statistical method can effectively resolve the aerosol components in urban area and distinguish between local and remote area aerosol components. The atmospheric aerosol samples were collected at four representative sites with an 8-stage cascade impactor sampler and analyzed for their elemental mass concentrations by PIXE analytic method. Based on some indicator elements, the characteristics of size distributions of particles from different sources were obtained

  12. Temperature sensitivity analysis of polarity controlled electrostatically doped tunnel field-effect transistor

    Science.gov (United States)

    Nigam, Kaushal; Pandey, Sunil; Kondekar, P. N.; Sharma, Dheeraj

    2016-09-01

    The conventional tunnel field-effect transistors (TFETs) have shown potential to scale down in sub-22 nm regime due to its lower sub-threshold slope and robustness against short-channel effects (SCEs), however, sensitivity towards temperature variation is a major concern. Therefore, for the first time, we investigate temperature sensitivity analysis of a polarity controlled electrostatically doped tunnel field-effect transistor (ED-TFET). Different performance metrics and analog/RF figure-of-merits were considered and compared for both devices, and simulations were performed using Silvaco ATLAS device tool. We found that the variation in ON-state current in ED-TFET is almost temperature independent due to electrostatically doped mechanism, while, it increases in conventional TFET at higher temperature. Above room temperature, the variation in ION, IOFF, and SS sensitivity in ED-TFET are only 0.11%/K, 2.21%/K, and 0.63%/K, while, in conventional TFET the variations are 0.43%/K, 2.99%/K, and 0.71%/K, respectively. However, below room temperature, the variation in ED-TFET ION is 0.195%/K compared to 0.27%/K of conventional TFET. Moreover, it is analysed that the incomplete ionization effect in conventional TFET severely affects the drive current and the threshold voltage, while, ED-TFET remains unaffected. Hence, the proposed ED-TFET is less sensitive towards temperature variation and can be used for cryogenics as well as for high temperature applications.

  13. Source apportionment by PMF on elemental concentrations obtained by PIXE analysis of PM10 samples collected at the vicinity of lignite power plants and mines in Megalopolis, Greece

    International Nuclear Information System (INIS)

    Manousakas, M.; Diapouli, E.; Papaefthymiou, H.; Migliori, A.; Karydas, A.G.; Padilla-Alvarez, R.; Bogovac, M.; Kaiser, R.B.; Jaksic, M.; Bogdanovic-Radovic, I.; Eleftheriadis, K.

    2015-01-01

    Particulate matter (PM) is an important constituent of atmospheric pollution especially in areas under the influence of industrial emissions. Megalopolis is a small city of 10,000 inhabitants located in central Peloponnese in close proximity to three coal opencast mines and two lignite fired power plants. 50 PM 10 samples were collected in Megalopolis during the years 2009–11 for elemental and multivariate analysis. For the elemental analysis PIXE was used as one of the most effective techniques in APM analytical characterization. Altogether, the concentrations of 22 elements (Z = 11–33), whereas Black Carbon was also determined for each sample using a reflectometer. Factorization software was used (EPA PMF 3.0) for source apportionment analysis. The analysis revealed that major emission sources were soil dust 33% (7.94 ± 0.27 μg/m 3 ), biomass burning 19% (4.43 ± 0.27 μg/m 3 ), road dust 15% (3.63 ± 0.37 μg/m 3 ), power plant emissions 13% (3.01 ± 0.44 μg/m 3 ), traffic 12% (2.82 ± 0.37 μg/m 3 ), and sea spray 8% (1.99 ± 0.41 μg/m 3 ). Wind trajectories have suggested that metals associated with emission from the power plants came mainly from west and were connected with the locations of the lignite mines located in this area. Soil resuspension, road dust and power plant emissions increased during the warm season of the year, while traffic/secondary, sea spray and biomass burning become dominant during the cold season

  14. Source apportionment by PMF on elemental concentrations obtained by PIXE analysis of PM10 samples collected at the vicinity of lignite power plants and mines in Megalopolis, Greece

    Science.gov (United States)

    Manousakas, M.; Diapouli, E.; Papaefthymiou, H.; Migliori, A.; Karydas, A. G.; Padilla-Alvarez, R.; Bogovac, M.; Kaiser, R. B.; Jaksic, M.; Bogdanovic-Radovic, I.; Eleftheriadis, K.

    2015-04-01

    Particulate matter (PM) is an important constituent of atmospheric pollution especially in areas under the influence of industrial emissions. Megalopolis is a small city of 10,000 inhabitants located in central Peloponnese in close proximity to three coal opencast mines and two lignite fired power plants. 50 PM10 samples were collected in Megalopolis during the years 2009-11 for elemental and multivariate analysis. For the elemental analysis PIXE was used as one of the most effective techniques in APM analytical characterization. Altogether, the concentrations of 22 elements (Z = 11-33), whereas Black Carbon was also determined for each sample using a reflectometer. Factorization software was used (EPA PMF 3.0) for source apportionment analysis. The analysis revealed that major emission sources were soil dust 33% (7.94 ± 0.27 μg/m3), biomass burning 19% (4.43 ± 0.27 μg/m3), road dust 15% (3.63 ± 0.37 μg/m3), power plant emissions 13% (3.01 ± 0.44 μg/m3), traffic 12% (2.82 ± 0.37 μg/m3), and sea spray 8% (1.99 ± 0.41 μg/m3). Wind trajectories have suggested that metals associated with emission from the power plants came mainly from west and were connected with the locations of the lignite mines located in this area. Soil resuspension, road dust and power plant emissions increased during the warm season of the year, while traffic/secondary, sea spray and biomass burning become dominant during the cold season.

  15. Silicon Drift Detector response function for PIXE spectra fitting

    Science.gov (United States)

    Calzolai, G.; Tapinassi, S.; Chiari, M.; Giannoni, M.; Nava, S.; Pazzi, G.; Lucarelli, F.

    2018-02-01

    The correct determination of the X-ray peak areas in PIXE spectra by fitting with a computer program depends crucially on accurate parameterization of the detector peak response function. In the Guelph PIXE software package, GUPIXWin, one of the most used PIXE spectra analysis code, the response of a semiconductor detector to monochromatic X-ray radiation is described by a linear combination of several analytical functions: a Gaussian profile for the X-ray line itself, and additional tail contributions (exponential tails and step functions) on the low-energy side of the X-ray line to describe incomplete charge collection effects. The literature on the spectral response of silicon X-ray detectors for PIXE applications is rather scarce, in particular data for Silicon Drift Detectors (SDD) and for a large range of X-ray energies are missing. Using a set of analytical functions, the SDD response functions were satisfactorily reproduced for the X-ray energy range 1-15 keV. The behaviour of the parameters involved in the SDD tailing functions with X-ray energy is described by simple polynomial functions, which permit an easy implementation in PIXE spectra fitting codes.

  16. Dynamic modeling of geometrically nonlinear electrostatically actuated microbeams (Corotational Finite Element formulation and analysis)

    Energy Technology Data Exchange (ETDEWEB)

    Borhan, H; Ahmadian, M T [Sharif University of Technology, Center of Excellence for Design, Robotics and Automation, School of Mechanical Engineering, PO Box 11365-9567, Tehran (Iran, Islamic Republic of)

    2006-04-01

    In this paper, a complete nonlinear finite element model for coupled-domain MEMS devices with electrostatic actuation and squeeze film effect is developed. For this purpose, a corotational finite element formulation for the dynamic analysis of planer Euler beams is employed. In this method, the internal nodal forces due to deformation and intrinsic residual stresses, the inertial nodal forces, and the damping effect of squeezed air film are systematically derived by consistent linearization of the fully geometrically nonlinear beam theory using d'Alamber and virtual work principles. An incremental-iterative method based on the Newmark direct integration procedure and the Newton-Raphson algorithm is used to solve the nonlinear dynamic equilibrium equations. Numerical examples are presented and compared with experimental findings which indicate properly good agreement.

  17. Determination of Hg concentration in gases by PIXE

    Science.gov (United States)

    Dutkiewicz, E.; van Kuijen, W. J. P.; Munnik, F.; Mutsaers, P. H. A.; Rokita, E.; de Voigt, M. J. A.

    1992-05-01

    A method for determination of the concentration of mercury in the gaseous phase is described. In the first step of the method a stable sulphur-mercury complex is formed. For this purpose sulphur is deposited on a filter and the investigated gas flows through the filter. Millipore filters and the deposition of sulphur from Na2S2O3 * 5H2O solution were found to be most suitable. The amount of Hg absorbed on the filter was determined by PIXE or by NAA in the second step of the method. An optimization of proton energy was performed in the PIXE analysis to obtain the maximal signal-to-background ratio. The detection limit of the method, expressed as the minimal amount of Hg which has to flow through the filter equals to 30 and 2 ng for PIXE and NAA techniques, respectively. Applications of the method are also described.

  18. Portable XRF and PIXE as complementary techniques for the analysis of old books: study of decorated flyleaves and edges; FRX portatil y PIXE como tecnicas complementarias para el analisis de libros antiguos: estudio de guardas y cantos decorados

    Energy Technology Data Exchange (ETDEWEB)

    Torner M, L.; Gonzalez T, C. [Laboratorio de Conservacion, Biblioteca Nacional de Antropologia e Historia, INAH, Paseo dela Reforma y Gandhi s/n Chapultepec Polanco, Mexico DF 11560 (Mexico); Ruvalcaba S, J.L. [Instituto de Fisica, UNAM. A.P. 20-364, Mexico DF 01000 (Mexico)]. e-mail: luciatorner@gmail.com

    2006-07-01

    Traditionally in the study of ancient books, the binding (leather, parchment, cloth) and their decorations have not the same importance than other parts of the book. Most of the times, paper, inks and internal decorations attract entirely the attention for analytical studies. Nevertheless, it must be considered that the binding keep the book safe and it may be exposed D higher deterioration. Moreover, often it is changed and the historical value of this part of the book is lost. his is also the case of binding's decorations. For these reasons, it is clear that the binding of ancient books must be studied as a part of their material essence. In this work, methodology based on t]he combined use of microscopic and elemental analyses was applied in order to study four types of decorations of guards of books (marbled, colored, splashed, dotted). In particular, this study was focused on Colonial and Mexican books from XVIII and XIX centuries from the collection of the Biblioteca Nacional de Antropologia e Historia, lNAH. Twelve books and 62 decoration's colors were analyzed in situ, in the library, using a portable X-ray Fluorescence Spectroscopy system (XRF) for a quick nondestructive pigment identification and to select a reduced number of books for complementary analyses at the laboratory by Particle Induced X-ray Emission Spectroscopy (PIXE). By combining these nondestructive techniques, it was possible to identify most of the pigments used in the decorations and to establish a general pattern of use of colorants and pigments in XVIII and XIX centuries for the guard's decorations. This work represents the first study on this topic. (Author)

  19. Trace element fingerprinting of jewellery rubies by external beam PIXE

    International Nuclear Information System (INIS)

    Calligaro, T.; Poirot, J.-P.; Querre, G.

    1999-01-01

    External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies: one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional geological observations

  20. Trace element fingerprinting of jewellery rubies by external beam PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T. E-mail: calli@culture.nl; Poirot, J.-P.; Querre, G

    1999-04-02

    External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies: one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional geological observations.

  1. Finite Element Analysis of the Vertical Levitation Force in an Electrostatic MEMS Comb Drive Actuator

    International Nuclear Information System (INIS)

    Wooldridge, J; Blackburn, J; Muniz-Piniella, A; Stewart, M; Shean, T A V; Weaver, P M; Cain, M G

    2013-01-01

    A vertical levitation electrostatic comb drive actuator was manufactured for the purpose of measuring piezoelectric coefficients in small-scale materials and devices. Previous modelling work on comb drive levitation has focussed on control of the levitation in standard poly-silicon devices in order to minimize effects on lateral modes of operation required for the accelerometer and gyroscope applications. The actuator developed in this study was manufactured using a 20 μm electroplated Ni process with a 25 μm trench created beneath the released structure through chemical wet etching. A finite element analysis using ZINC was used to model electrostatic potential around a cross section of one static and one movable electrode, from which the net levitation force per unit electrode was calculated. The model was first verified using the electrode geometry from previously studied systems, and then used to study the variation of force as a function of decreasing substrate-electrode distance. With the top electrode surfaces collinear the calculated force density is 0.00651 ε 0 V 2 M μm −1 , equivalent to a total force for the device of 36.4 μN at an applied voltage of V M =100 V, just 16% larger than the observed value. The measured increase in force with distance was smaller than predicted with the FEA, due to the geometry of the device in which the electrodes at the anchored ends of the supporting spring structure displace by a smaller amount than those at the centre

  2. Pixe method as microanalytical instrument

    International Nuclear Information System (INIS)

    Tabacniks, M.H.

    1986-02-01

    The PIXE method (Particle Induced X-Ray Emission) as analytical method presenting the evolution, the theoretical fundaments, the detection limit, the optimization for operational conditions is evaluated. The applications of the method to air pollution control and aerosol studies in regions such as Antartic, Amazon and other regions are analysed. (M.C.K.) [pt

  3. A comb-sampling method for enhanced mass analysis in linear electrostatic ion traps

    Energy Technology Data Exchange (ETDEWEB)

    Greenwood, J. B.; Kelly, O.; Calvert, C. R.; Duffy, M. J.; King, R. B.; Belshaw, L.; Graham, L.; Alexander, J. D.; Williams, I. D. [Centre for Plasma Physics, School of Mathematics and Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Bryan, W. A. [Department of Physics, Swansea University, Swansea SA2 8PP (United Kingdom); Turcu, I. C. E.; Cacho, C. M.; Springate, E. [Central Laser Facility, STFC Rutherford Appleton Laboratory, Didcot, Oxfordshire OX11 0QX (United Kingdom)

    2011-04-15

    In this paper an algorithm for extracting spectral information from signals containing a series of narrow periodic impulses is presented. Such signals can typically be acquired by pickup detectors from the image-charge of ion bunches oscillating in a linear electrostatic ion trap, where frequency analysis provides a scheme for high-resolution mass spectrometry. To provide an improved technique for such frequency analysis, we introduce the CHIMERA algorithm (Comb-sampling for High-resolution IMpulse-train frequency ExtRAaction). This algorithm utilizes a comb function to generate frequency coefficients, rather than using sinusoids via a Fourier transform, since the comb provides a superior match to the data. This new technique is developed theoretically, applied to synthetic data, and then used to perform high resolution mass spectrometry on real data from an ion trap. If the ions are generated at a localized point in time and space, and the data is simultaneously acquired with multiple pickup rings, the method is shown to be a significant improvement on Fourier analysis. The mass spectra generated typically have an order of magnitude higher resolution compared with that obtained from fundamental Fourier frequencies, and are absent of large contributions from harmonic frequency components.

  4. Non linear-least-squares fitting for pixe spectra

    International Nuclear Information System (INIS)

    Benamar, M.A.; Tchantchane, A.; Benouali, N.; Azbouche, A.; Tobbeche, S.

    1992-10-01

    An interactive computer program for the analysis of Pixe spectra is described. The fitting procedure consists of computing a function which approximates the experimental data. A nonlinear least-squares fitting is used to determine the parameters of the fit. The program takes into account the low energy tail and the escape peaks

  5. Diagnosis of spatial resolution for microbeam scanning PIXE using STIM method and CR-39 track detector in PASTA

    International Nuclear Information System (INIS)

    Hamano, T.; Imaseki, H.; Yukawa, M.; Ishikawa, T.; Iso, H.; Matsumoto, K.

    2003-01-01

    In PIXE analysis system and Tandem Accelerator facility (PASTA) of NIRS, we are using Scanning Transmission Ion Microscopy (STIM) method and solid track detector to diagnose the spatial resolution of scanning microbeam PIXE analysis system. These methods are widely used by many microbeam facilities. (author)

  6. Present role of PIXE in atmospheric aerosol research

    Energy Technology Data Exchange (ETDEWEB)

    Maenhaut, Willy, E-mail: Willy.Maenhaut@UGent.be

    2015-11-15

    In the 1980s and 1990s nearly half of the elemental analyses of atmospheric aerosol samples were performed by PIXE. Since then, other techniques for elemental analysis became available and there has been a steady increase in studies on organic aerosol constituents and other aspects of aerosols, especially in the areas of nucleation (new particle formation), optical properties, and the role of aerosol particles in cloud formation and properties. First, a brief overview and discussion is given of the developments and trends in atmospheric aerosol analysis and research of the past three decades. Subsequently, it is indicated that there is still invaluable work to be done by PIXE in atmospheric aerosol research, especially if one teams up with other aerosol researchers and performs complementary measurements, e.g., on small aerosol samples that are taken with high-time resolution. Fine examples of such research are the work done by the Lund group in the CARIBIC aircraft studies and the analysis of circular streaker samples by the Florence PIXE group. These and other examples are presented and other possibilities of PIXE are indicated.

  7. Micro-PIXE for the quantitative imaging of chemical elements in single cells

    International Nuclear Information System (INIS)

    Ortega, R.

    2013-01-01

    Full text: The knowledge of the intracellular distribution of biological relevant metals is important to understand their mechanisms of action in cells, either for physiological, toxicological or pathological processes. However, the direct detection of trace metals in single cells is a challenging task that requires sophisticated analytical developments. The aim of this seminar will be to present the recent achievements in this field using micro-PIXE analysis. The combination of micro-PIXE with RBS (Rutherford Backscattering Spectrometry) and STIM (Scanning Transmission lon Microscopy) allows the quantitative determination of trace metal content within sub-cellular compartments. The application of STlM analysis will be more specifically highlighted as it provides high spatial resolution imaging (<200 nm) and excellent mass sensitivity (<0.1 ng). Application of the STIM-PIXE-RBS methodology is absolutely needed when organic mass loss appears during PIXE-RBS irradiation. This combination of STIM-PIXE-RBS provides fully quantitative determination of trace element content, expressed in μg/g, which is a quite unique capability for micro-PIXE compared to other micro-analytical methods such as the electron and synchrotron X-ray fluorescence or the techniques based on mass spectrometry. Examples of micro-PIXE studies for subcellular imaging of trace elements in the various fields of interest will be presented such as metal-based toxicology, pharmacology, and neuro degeneration [1] R. Ortega, G. Devés, A. Carmona. J. R. Soc. Interface, 6, (2009) S649-S658. (author)

  8. Multi-elemental analysis of atmospheric pollutants and determination of particle size using the PIXE method, a cascade impactor and a filter unit constructed in Mexico

    International Nuclear Information System (INIS)

    Aldape U, F.

    1989-01-01

    This work presents: 1) The methodology and the experimental conditions of the PIXE technique so that it is used as a better option inside the analytical methods in aerosols studies, 2) The development, tests and applications of a cascade impactor of the Batelle type built to determine particle size to use it jointly with the mentioned technique in the determination of the elements concentration according to its size.By this way is fulfilled with the first goal of this extensive project. (Author)

  9. Mathematical analysis of the boundary-integral based electrostatics estimation approximation for molecular solvation: exact results for spherical inclusions.

    Science.gov (United States)

    Bardhan, Jaydeep P; Knepley, Matthew G

    2011-09-28

    We analyze the mathematically rigorous BIBEE (boundary-integral based electrostatics estimation) approximation of the mixed-dielectric continuum model of molecular electrostatics, using the analytically solvable case of a spherical solute containing an arbitrary charge distribution. Our analysis, which builds on Kirkwood's solution using spherical harmonics, clarifies important aspects of the approximation and its relationship to generalized Born models. First, our results suggest a new perspective for analyzing fast electrostatic models: the separation of variables between material properties (the dielectric constants) and geometry (the solute dielectric boundary and charge distribution). Second, we find that the eigenfunctions of the reaction-potential operator are exactly preserved in the BIBEE model for the sphere, which supports the use of this approximation for analyzing charge-charge interactions in molecular binding. Third, a comparison of BIBEE to the recent GBε theory suggests a modified BIBEE model capable of predicting electrostatic solvation free energies to within 4% of a full numerical Poisson calculation. This modified model leads to a projection-framework understanding of BIBEE and suggests opportunities for future improvements. © 2011 American Institute of Physics

  10. The potential of PIXE analytical work in water pollution

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, H.; Takahashi, Y.; Ishii, K. [Dept. of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Sendai, Miyagi (JP)] [and others

    1999-07-01

    A method has been developed and tested for PIXE analysis of soluble and insoluble constituents in a variety of water samples in our surroundings. Insoluble components were filtered on a Nuclepore filter of 0.4-{mu}m pores. For soluble fractions, a target of major components was made from a 0.15-ml filtrate evaporated on a user-made polycarbonate film, and in turn heavy metals in trace amounts were preconcentrated in a PIXE-target through the use of a combination of dibenzyldithiocarbamate-chelation with subsequent condensation into dibenzylidene-D-sorbitol gels. These three kinds of targets were analyzed with a PIXE system of 3-MeV proton beams. The widespread concentrations (several tenths of ppb to a few tens of ppm) of {approx}24 elements from Na to Pb were determined simultaneously in a precision sufficient to reveal the elemental distribution between the soluble and insoluble fractions of various aqueous sample such as river water, rain water and water leaking from disposal sites of industrial wastes. Hence, the methodology for preparing three types of targets promotes the PIXE analysis to a truly effective means for monitoring a water-pollution problem in our surroundings. (author)

  11. The potential of PIXE analytical work in water pollution

    International Nuclear Information System (INIS)

    Yamazaki, H.; Takahashi, Y.; Ishii, K.

    1999-01-01

    A method has been developed and tested for PIXE analysis of soluble and insoluble constituents in a variety of water samples in our surroundings. Insoluble components were filtered on a Nuclepore filter of 0.4-μm pores. For soluble fractions, a target of major components was made from a 0.15-ml filtrate evaporated on a user-made polycarbonate film, and in turn heavy metals in trace amounts were preconcentrated in a PIXE-target through the use of a combination of dibenzyldithiocarbamate-chelation with subsequent condensation into dibenzylidene-D-sorbitol gels. These three kinds of targets were analyzed with a PIXE system of 3-MeV proton beams. The widespread concentrations (several tenths of ppb to a few tens of ppm) of ∼24 elements from Na to Pb were determined simultaneously in a precision sufficient to reveal the elemental distribution between the soluble and insoluble fractions of various aqueous sample such as river water, rain water and water leaking from disposal sites of industrial wastes. Hence, the methodology for preparing three types of targets promotes the PIXE analysis to a truly effective means for monitoring a water-pollution problem in our surroundings. (author)

  12. Automatic classification of singular elements for the electrostatic analysis of microelectromechanical systems

    Science.gov (United States)

    Su, Y.; Ong, E. T.; Lee, K. H.

    2002-05-01

    The past decade has seen an accelerated growth of technology in the field of microelectromechanical systems (MEMS). The development of MEMS products has generated the need for efficient analytical and simulation methods for minimizing the requirement for actual prototyping. The boundary element method is widely used in the electrostatic analysis for MEMS devices. However, singular elements are needed to accurately capture the behavior at singular regions, such as sharp corners and edges, where standard elements fail to give an accurate result. The manual classification of boundary elements based on their singularity conditions is an immensely laborious task, especially when the boundary element model is large. This process can be automated by querying the geometric model of the MEMS device for convex edges based on geometric information of the model. The associated nodes of the boundary elements on these edges can then be retrieved. The whole process is implemented in the MSC/PATRAN platform using the Patran Command Language (the source code is available as supplementary data in the electronic version of this journal issue).

  13. Electrostatic analysis of n-doped SrTiO3 metal-insulator-semiconductor systems

    International Nuclear Information System (INIS)

    Kamerbeek, A. M.; Banerjee, T.; Hueting, R. J. E.

    2015-01-01

    Electron doped SrTiO 3 , a complex-oxide semiconductor, possesses novel electronic properties due to its strong temperature and electric-field dependent permittivity. Due to the high permittivity, metal/n-SrTiO 3 systems show reasonably strong rectification even when SrTiO 3 is degenerately doped. Our experiments show that the insertion of a sub nanometer layer of AlO x in between the metal and n-SrTiO 3 interface leads to a dramatic reduction of the Schottky barrier height (from around 0.90 V to 0.25 V). This reduces the interface resistivity by 4 orders of magnitude. The derived electrostatic analysis of the metal-insulator-semiconductor (n-SrTiO 3 ) system is consistent with this trend. When compared with a Si based MIS system, the change is much larger and mainly governed by the high permittivity of SrTiO 3 . The non-linear permittivity of n-SrTiO 3 leads to unconventional properties such as a temperature dependent surface potential non-existent for semiconductors with linear permittivity such as Si. This allows tuning of the interfacial band alignment, and consequently the Schottky barrier height, in a much more drastic way than in conventional semiconductors

  14. Probing lipid membrane electrostatics

    Science.gov (United States)

    Yang, Yi

    The electrostatic properties of lipid bilayer membranes play a significant role in many biological processes. Atomic force microscopy (AFM) is highly sensitive to membrane surface potential in electrolyte solutions. With fully characterized probe tips, AFM can perform quantitative electrostatic analysis of lipid membranes. Electrostatic interactions between Silicon nitride probes and supported zwitterionic dioleoylphosphatidylcholine (DOPC) bilayer with a variable fraction of anionic dioleoylphosphatidylserine (DOPS) were measured by AFM. Classical Gouy-Chapman theory was used to model the membrane electrostatics. The nonlinear Poisson-Boltzmann equation was numerically solved with finite element method to provide the potential distribution around the AFM tips. Theoretical tip-sample electrostatic interactions were calculated with the surface integral of both Maxwell and osmotic stress tensors on tip surface. The measured forces were interpreted with theoretical forces and the resulting surface charge densities of the membrane surfaces were in quantitative agreement with the Gouy-Chapman-Stern model of membrane charge regulation. It was demonstrated that the AFM can quantitatively detect membrane surface potential at a separation of several screening lengths, and that the AFM probe only perturbs the membrane surface potential by external field created by the internai membrane dipole moment. The analysis yields a dipole moment of 1.5 Debye per lipid with a dipole potential of +275 mV for supported DOPC membranes. This new ability to quantitatively measure the membrane dipole density in a noninvasive manner will be useful in identifying the biological effects of the dipole potential. Finally, heterogeneous model membranes were studied with fluid electric force microscopy (FEFM). Electrostatic mapping was demonstrated with 50 nm resolution. The capabilities of quantitative electrostatic measurement and lateral charge density mapping make AFM a unique and powerful

  15. Resonant frequency analysis on an electrostatically actuated microplate under uniform hydrostatic pressure

    International Nuclear Information System (INIS)

    Li Zhikang; Zhao Libo; Ye Zhiying; Zhao Yulong; Jiang Zhuangde; Wang Hongyan

    2013-01-01

    The resonant frequency of a microplate is influenced by various physical parameters such as mass, surface stress, hydrostatic pressure and electrostatic force. In this paper, the effects of both electrostatic force and uniform hydrostatic pressure on the resonant frequency of a clamped circular microplate are investigated. An approximate solution is derived for the fundamental resonance frequency of the mciroplate under both types of loads using an energy equivalent method. It is found that both electrostatic force and uniform hydrostatic pressure decrease the resonant frequency of the microplate under small deflections. Additionally, the linearized expression of this solution shows that the resonant frequency varies linearly with pressure in the low and ultra-low range, and the corresponding pressure sensitivity depends on the voltage applied to the microplate. The analytical results are well validated by the finite element method. This study may be helpful for the design and optimization of electrostatically actuated resonance devices based on microplates, especially electrostatically actuated low- or ultra-low-pressure sensors. (paper)

  16. Iron site location in Fe-diffused lithium niobate crystals by combined RBS-PIXE-NRA analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zaltron, A. [University of Padova and CNISM, Via Marzolo 8, 35131 Padova (Italy); Argiolas, N., E-mail: nicola.argiolas@unipd.it [University of Padova and CNISM, Via Marzolo 8, 35131 Padova (Italy); Laboratori Nazionali di Legnaro, Istituto Nazionale Fisica Nucleare, Viale dell' Universita 2, 35020 Legnaro (Padova) (Italy); De Salvador, D.; Bazzan, M. [University of Padova and CNISM, Via Marzolo 8, 35131 Padova (Italy); Laboratori Nazionali di Legnaro, Istituto Nazionale Fisica Nucleare, Viale dell' Universita 2, 35020 Legnaro (Padova) (Italy); Ciampolillo, M.V.; Bacci, L.; Sada, C. [University of Padova and CNISM, Via Marzolo 8, 35131 Padova (Italy)

    2012-03-15

    Iron diffused x-cut lithium niobate samples have been studied from a structural point of view by ion beam analysis techniques in channeling conditions. The aim of this work is to determine the most probable position of iron atoms after high temperature diffusion treatment in pure oxygen atmosphere and to verify their location after an additional full reducing annealing at low temperature. The results are compared with the bulk doping case that can be considered the final equilibrium state of the diffusion process. By comparing the iron signal with niobium and lithium counterparts in angular scans along proper crystallographic directions, we demonstrate that iron occupies in any case the lithium site or a very close position regardless of the reduction degree, just as in the case of bulk doped samples.

  17. Fish gelatin thin film standards for biological application of PIXE

    Science.gov (United States)

    Manuel, Jack E.; Rout, Bibhudutta; Szilasi, Szabolcs Z.; Bohara, Gyanendra; Deaton, James; Luyombya, Henry; Briski, Karen P.; Glass, Gary A.

    2014-08-01

    There exists a critical need to understand the flow and accumulation of metallic ions, both naturally occurring and those introduced to biological systems. In this paper the results of fabricating thin film elemental biological standards containing nearly any combination of trace elements in a protein matrix are presented. Because it is capable of high elemental sensitivity, particle induced X-ray emission spectrometry (PIXE) is an excellent candidate for in situ analysis of biological tissues. Additionally, the utilization of microbeam PIXE allows the determination of elemental concentrations in and around biological cells. However, obtaining elemental reference standards with the same matrix constituents as brain tissue is difficult. An excellent choice for simulating brain-like tissue is Norland® photoengraving glue which is derived from fish skin. Fish glue is water soluble, liquid at room temperature, and resistant to dilute acid. It can also be formed into a thin membrane which dries into a durable, self-supporting film. Elements of interest are introduced to the fish glue in precise volumetric additions of well quantified atomic absorption standard solutions. In this study GeoPIXE analysis package is used to quantify elements intrinsic to the fish glue as well as trace amounts of manganese added to the sample. Elastic (non-Rutherford) backscattered spectroscopy (EBS) and the 1.734 MeV proton-on-carbon 12C(p,p)12C resonance is used for a normalization scheme of the PIXE spectra to account for any discrepancies in X-ray production arising from thickness variation of the prepared standards. It is demonstrated that greater additions of the atomic absorption standard cause a viscosity reduction of the liquid fish glue resulting in thinner films but the film thickness can be monitored by using simultaneous PIXE and EBS proton data acquisition.

  18. Fish gelatin thin film standards for biological application of PIXE

    International Nuclear Information System (INIS)

    Manuel, Jack E.; Rout, Bibhudutta; Szilasi, Szabolcs Z.; Bohara, Gyanendra; Deaton, James; Luyombya, Henry; Briski, Karen P.; Glass, Gary A.

    2014-01-01

    There exists a critical need to understand the flow and accumulation of metallic ions, both naturally occurring and those introduced to biological systems. In this paper the results of fabricating thin film elemental biological standards containing nearly any combination of trace elements in a protein matrix are presented. Because it is capable of high elemental sensitivity, particle induced X-ray emission spectrometry (PIXE) is an excellent candidate for in situ analysis of biological tissues. Additionally, the utilization of microbeam PIXE allows the determination of elemental concentrations in and around biological cells. However, obtaining elemental reference standards with the same matrix constituents as brain tissue is difficult. An excellent choice for simulating brain-like tissue is Norland® photoengraving glue which is derived from fish skin. Fish glue is water soluble, liquid at room temperature, and resistant to dilute acid. It can also be formed into a thin membrane which dries into a durable, self-supporting film. Elements of interest are introduced to the fish glue in precise volumetric additions of well quantified atomic absorption standard solutions. In this study GeoPIXE analysis package is used to quantify elements intrinsic to the fish glue as well as trace amounts of manganese added to the sample. Elastic (non-Rutherford) backscattered spectroscopy (EBS) and the 1.734 MeV proton-on-carbon 12 C(p,p) 12 C resonance is used for a normalization scheme of the PIXE spectra to account for any discrepancies in X-ray production arising from thickness variation of the prepared standards. It is demonstrated that greater additions of the atomic absorption standard cause a viscosity reduction of the liquid fish glue resulting in thinner films but the film thickness can be monitored by using simultaneous PIXE and EBS proton data acquisition

  19. Fish gelatin thin film standards for biological application of PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Manuel, Jack E., E-mail: jaelma@gmail.com [Ion Beam Modification and Analysis Laboratory, University of North Texas, Denton, TX 76203 (United States); Rout, Bibhudutta; Szilasi, Szabolcs Z.; Bohara, Gyanendra [Ion Beam Modification and Analysis Laboratory, University of North Texas, Denton, TX 76203 (United States); Deaton, James; Luyombya, Henry [Louisiana Accelerator Center, University of Louisiana at Lafayette, Lafayette, LA 70503 (United States); Briski, Karen P. [Department of Basic Pharmaceutical Sciences, University of Louisiana at Monroe, Monroe, LA 71209 (United States); Glass, Gary A. [Ion Beam Modification and Analysis Laboratory, University of North Texas, Denton, TX 76203 (United States)

    2014-08-01

    There exists a critical need to understand the flow and accumulation of metallic ions, both naturally occurring and those introduced to biological systems. In this paper the results of fabricating thin film elemental biological standards containing nearly any combination of trace elements in a protein matrix are presented. Because it is capable of high elemental sensitivity, particle induced X-ray emission spectrometry (PIXE) is an excellent candidate for in situ analysis of biological tissues. Additionally, the utilization of microbeam PIXE allows the determination of elemental concentrations in and around biological cells. However, obtaining elemental reference standards with the same matrix constituents as brain tissue is difficult. An excellent choice for simulating brain-like tissue is Norland® photoengraving glue which is derived from fish skin. Fish glue is water soluble, liquid at room temperature, and resistant to dilute acid. It can also be formed into a thin membrane which dries into a durable, self-supporting film. Elements of interest are introduced to the fish glue in precise volumetric additions of well quantified atomic absorption standard solutions. In this study GeoPIXE analysis package is used to quantify elements intrinsic to the fish glue as well as trace amounts of manganese added to the sample. Elastic (non-Rutherford) backscattered spectroscopy (EBS) and the 1.734 MeV proton-on-carbon {sup 12}C(p,p){sup 12}C resonance is used for a normalization scheme of the PIXE spectra to account for any discrepancies in X-ray production arising from thickness variation of the prepared standards. It is demonstrated that greater additions of the atomic absorption standard cause a viscosity reduction of the liquid fish glue resulting in thinner films but the film thickness can be monitored by using simultaneous PIXE and EBS proton data acquisition.

  20. Reactivity of etoricoxib based on computational study of molecular orbitals, molecular electrostatic potential surface and Mulliken charge analysis

    Science.gov (United States)

    Sachdeva, Ritika; Soni, Abhinav; Singh, V. P.; Saini, G. S. S.

    2018-05-01

    Etoricoxib is one of the selective cyclooxygenase inhibitor drug which plays a significant role in the pharmacological management of arthritis and pain. The theoretical investigation of its reactivity is done using Density Functional Theory calculations. Molecular Electrostatic Potential Surface of etoricoxib and its Mulliken atomic charge distribution are used for the prediction of its electrophilic and nucleophilic sites. The detailed analysis of its frontier molecular orbitals is also done.

  1. Electrostatic accelerators

    CERN Document Server

    Hinterberger, F

    2006-01-01

    The principle of electrostatic accelerators is presented. We consider Cockcroft– Walton, Van de Graaff and Tandem Van de Graaff accelerators. We resume high voltage generators such as cascade generators, Van de Graaff band generators, Pelletron generators, Laddertron generators and Dynamitron generators. The speci c features of accelerating tubes, ion optics and methods of voltage stabilization are described. We discuss the characteristic beam properties and the variety of possible beams. We sketch possible applications and the progress in the development of electrostatic accelerators.

  2. Greek silver drachmae of the roman civil war period, (first century BC) as reflected in external beam PIXE analysis

    International Nuclear Information System (INIS)

    Constantinescu, B.; Bugoi, R.; Catana, D.; Plostinaru, D.; Sasianu, A.; Kiss, A.; Uzonyi, I.

    1999-01-01

    The great number of Greek silver coins from the first century BC found in the Balkan - Carpathian region have aroused a sharp interest among numismatic researchers. The problem is to classify these coins - tetradrachmae of Thasos and drachmae of Apollonia and Dyrrachium into originals, copies and imitations, in relation to their provenance. Well known are Celtic Thasos tetradrachmae copies (good quality coins), and also Barbarian imitations (absence or misspelling of the legend, disproportionate and simplified figures). Thracians, Dacians and Celts used to produce the same type of coins. The dies used for coining were bought or stolen from the Greeks, while some local engravers manufactured their own dies. Visual examination, the first step of a numismatist's work, is insufficient to classify the coins. This is the reason why elemental analysis is required (X-Ray Fluorescence and Proton Induced X-ray Emission methods). 36 Thasos tetradrachmae and 145 Apollonia and Dyrrachium drachmae, struck between 60 and 48 BC, a very intense period of civil Roman wars, belonging to Tarii Crisurilor Museum in Oradea and to Budapest National Museum were analyzed. The fingerprint of the third group of Thasian tetradrachmae is the bromine. The presence of this element in silver coins is mentioned in the literature, where bromine is linked to marine spray (the hoard was found near the seacoast). In our case, the coins were found in a region far away from the Black Sea coast. Taking into account the presence of bromine in silver ore from the Transylvania mine Rodna and supposing an imperfect procedure of refinement , these coins could be attributed to local workshops. As for the Apollonia and Dyrrachium drachmae, a similar situation can be retraced. Because of the high silver content and refined aspect of the coins belonging to the first group, one can assume that these drachmae are the original ones, minted of Macedonian silver. The percentage of copper in the second group of coins

  3. PIXE facility at Centro Atomico Bariloche

    Energy Technology Data Exchange (ETDEWEB)

    Limandri, S.; Rodriguez, L. [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET) (Argentina); Olivares, C.; Bernardi, G. [Centro Atomico Bariloche, Comision Nacional de Energia Atomica, San Carlos de Bariloche, Rio Negro (Argentina); Suarez, S. [lnstituto Balseiro, Universidad Nacional de Cuyo, San Carlos de Bariloche, Rio Negro (Argentina)

    2013-07-01

    Full text: A Tandem accelerator, NEC Pelletron 5SDH, has been recently installed at Centro Atomico Bariloche, Argentina. This facility provides the local scientific community the opportunity to use nuclear techniques in different fields such as material science, environment (air, soil and food), biology, archaeology, etc.). The ion beam techniques available in our laboratory includes the ones commonly used in material analysis, i. e., PIXE (proton induced X-ray emission), RBS (Rutherford backscattering spectroscopy), PIGE (proton induced gamma ray emission), channeling and ERDA (elastic recall detection analysis). The line used for material analysis consists of a NEC-RC43 Endstation with setups and detectors for all the techniques above mentioned. This communication includes a description of the system facility and the main associated equipment, in particular that for PIXE measurements. In addition, we show some recent applications of PIXE to the study of archaeological ceramics, smokeless gun powders, and the experimental determination of the efficiency or our SDD detector. The detector efficiency was estimated for energies between 0.27 and 25 keV. The method applied is based on the comparison of X-ray characteristic intensities excited by 2-MeV protons in bulk samples with theoretical predictions. The results are compared with efficiency values obtained by the product of the window transmission and the detector quantum efficiency. Element constituents of black, white, brown and ocher pigments from Aguada Culture (600-900 before present) were studied. The results obtained are compared with measurements performed at the Laboratorio de Implantacao Ionica-UFRGS. This study is helpful to interpret the social, political economic and cultural contexts of pre-Inca societies and the interaction among different sites. Traces amounts present in seven smokeless gun powders commonly used in Argentina were determined. The powders were deposited on a carbon tape and the

  4. PIXE facility at Centro Atomico Bariloche

    International Nuclear Information System (INIS)

    Limandri, S.; Rodriguez, L.; Olivares, C.; Bernardi, G.; Suarez, S.

    2013-01-01

    Full text: A Tandem accelerator, NEC Pelletron 5SDH, has been recently installed at Centro Atomico Bariloche, Argentina. This facility provides the local scientific community the opportunity to use nuclear techniques in different fields such as material science, environment (air, soil and food), biology, archaeology, etc.). The ion beam techniques available in our laboratory includes the ones commonly used in material analysis, i. e., PIXE (proton induced X-ray emission), RBS (Rutherford backscattering spectroscopy), PIGE (proton induced gamma ray emission), channeling and ERDA (elastic recall detection analysis). The line used for material analysis consists of a NEC-RC43 Endstation with setups and detectors for all the techniques above mentioned. This communication includes a description of the system facility and the main associated equipment, in particular that for PIXE measurements. In addition, we show some recent applications of PIXE to the study of archaeological ceramics, smokeless gun powders, and the experimental determination of the efficiency or our SDD detector. The detector efficiency was estimated for energies between 0.27 and 25 keV. The method applied is based on the comparison of X-ray characteristic intensities excited by 2-MeV protons in bulk samples with theoretical predictions. The results are compared with efficiency values obtained by the product of the window transmission and the detector quantum efficiency. Element constituents of black, white, brown and ocher pigments from Aguada Culture (600-900 before present) were studied. The results obtained are compared with measurements performed at the Laboratorio de Implantacao Ionica-UFRGS. This study is helpful to interpret the social, political economic and cultural contexts of pre-Inca societies and the interaction among different sites. Traces amounts present in seven smokeless gun powders commonly used in Argentina were determined. The powders were deposited on a carbon tape and the

  5. Multipolar electrostatics.

    Science.gov (United States)

    Cardamone, Salvatore; Hughes, Timothy J; Popelier, Paul L A

    2014-06-14

    Atomistic simulation of chemical systems is currently limited by the elementary description of electrostatics that atomic point-charges offer. Unfortunately, a model of one point-charge for each atom fails to capture the anisotropic nature of electronic features such as lone pairs or π-systems. Higher order electrostatic terms, such as those offered by a multipole moment expansion, naturally recover these important electronic features. The question remains as to why such a description has not yet been widely adopted by popular molecular mechanics force fields. There are two widely-held misconceptions about the more rigorous formalism of multipolar electrostatics: (1) Accuracy: the implementation of multipole moments, compared to point-charges, offers little to no advantage in terms of an accurate representation of a system's energetics, structure and dynamics. (2) Efficiency: atomistic simulation using multipole moments is computationally prohibitive compared to simulation using point-charges. Whilst the second of these may have found some basis when computational power was a limiting factor, the first has no theoretical grounding. In the current work, we disprove the two statements above and systematically demonstrate that multipole moments are not discredited by either. We hope that this perspective will help in catalysing the transition to more realistic electrostatic modelling, to be adopted by popular molecular simulation software.

  6. New results of GridPix TPCs

    International Nuclear Information System (INIS)

    Graaf, Harry van der

    2009-01-01

    The Gossip detector, being a GridPix TPC equipped with a thin layer of gas, is a promising alternative for Si tracking detectors. In addition, GridPix would be an interesting way to read out the gaseous phase volume of bi-phase Liquid Xe cryostats of v-less double beta decay and rare event (i.e. WIMP) search experiments.

  7. New results of GridPix TPCs

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Harry van der, E-mail: vdgraaf@nikhef.n [Science Park 105 1098 XG Amsterdam (Netherlands)

    2009-07-01

    The Gossip detector, being a GridPix TPC equipped with a thin layer of gas, is a promising alternative for Si tracking detectors. In addition, GridPix would be an interesting way to read out the gaseous phase volume of bi-phase Liquid Xe cryostats of v-less double beta decay and rare event (i.e. WIMP) search experiments.

  8. PIXE studies of pollutants in plants

    International Nuclear Information System (INIS)

    Szymczyk, S.; Kajfosz, J.; Hrynkiewicz, A.; Curzydlo, J.

    1980-01-01

    Both industrial and road traffic pollutions were studied by PIXE by means of determination of trace elements accumulated in different plant tissues from affected areas. The method was improved by the application of an intermediate atmosphere in the target chamber. The PIXE method was proved to be adequate and convenient for monitoring many of the pollutants. (author)

  9. Modal analysis and modeling of a frictionless electrostatic rotary stepper micromotor

    NARCIS (Netherlands)

    Stranczl, M.; Sarajlic, Edin; Krijnen, Gijsbertus J.M.; Fujita, H.; Gijs, M.A.M.; Yamahata, C.

    2011-01-01

    We present the design, modeling and characterization of a 3-phase electrostatic rotary stepper micromotor. The proposed motor is a monolithic device fabricated using silicon-on-insulator (SOI) technology. The rotor is suspended with a frictionless flexural pivot bearing and reaches an unprecedented

  10. In-vivo elemental imaging of plants using in-air submilli-PIXE camera

    International Nuclear Information System (INIS)

    Matsuyama, Shigeo; Ishii, Keizo; Kikuchi, Yohei; Kawamura, Yu; Yamazaki, Hiromichi; Watanabe, Ryohei; Tashiro, Kumiko; Inoue, Chihiro

    2008-01-01

    We developed a PIXE analysis system which provides spatial distribution images of elements in a region of 3x3 cm 2 with a spatial resolution of ∼0.5 mm. We call this system a submilli-PIXE camera. For in-vivo imaging of plants, we combined the submilli-PIXE camera with an in-air analysis. The high-speed beam scanning and the in-air analysis also reduce the risk of damaging the plants, thus in-vivo imaging could be realized. We applied the in-air submilli-PIXE camera to phytoremediation research. Phytoremediation is a technology for cleaning metal-contaminated soils using plant physiology. To study accumulation mechanisms for heavy metals, elemental distribution in plant organ should be known as well as average concentration. Elemental images of fronds were obtained in-vivo without sample preparation. Elemental map of the fronds showed that arsenic was accumulated in the edges of Pteris vittata fronds. The in-air submilli-PIXE camera clearly shows the accumulation of arsenic in fronds. The in-air submilli-PIXE camera is an effective tool for undertaking phytoremediation research. (author)

  11. The Byzantine ceramics from Pergamon excavations. Characterization of local and imported productions by elementary analysis using PIXE and INAA methods and by petrography; Les ceramiques byzantines des fouilles de Pergame. Caracterisation des productions locales et importees par analyse elementaire par les methodes PIXE et INAA et par petrographie

    Energy Technology Data Exchange (ETDEWEB)

    Waksman, S Y

    1995-01-12

    An important ceramics material dated back to the 12th-14th centuries has been excavated in Pergamon (Turkey). Among these findings, wasters, tripod stilts and unfinished ware attest to local production in the Byzantine period. Elemental analysis by the methods PIXE (Particle Induced X-ray Emission) and INAA (Instrumental Neutron Activation Analysis) has been performed on a representative sampling of 160 sherds, including attested local material. Multivariate statistical techniques were used to classify the sherds into groups of similar composition and thus to distinguish ceramics made in Pergamon from imported wares. Several groups of local production have been constituted, which correspond to wares differing in date and fabric. The geochemical characterization of the pastes, complemented with petrographical and mineralogical data, shows that specific raw materials have been used to manufacture each ware. The analytical data related to ceramics made in Pergamon will serve as reference data for future provenance studies. Such reference groups of Byzantine ceramics are very rare, and therefore the ceramics imported into Pergamon cannot be attributed as to their origin. Among the ceramics widely diffused in the Byzantine world, some importations belonging to the ``fine sgraffito`` and ``Zeuxippus ware`` types have been identified. The latter type has been a source of stylistic influence for the workshops of Pergamon, since the analyses show that imitated ``Zeuxippus ware`` has been produced there. These imitations were probably themselves diffused on a regional scale. (author). 238 refs., 48 figs., 53 tabs., 22 photos., 8 appends.

  12. PIXE in 1980: Summary of the second international conference on particle induced x-ray emission and its analytical applications

    International Nuclear Information System (INIS)

    Akselsson, K.R.

    1981-01-01

    The Second International Conference on Particle Induced X-ray Emission (PIXE) and its analytical applications was held in Lund, Sweden, June 9-12, 1980. About a hundred papers were presented, including seven invited talks (PIXE and particle scattering, microbeam analysis, applications to aerosols and biological samples). The main impression left by the conference was that both the PIXE method and its applications are in a phase of fast development. Considerable effort has successfully been devoted to optimizing the basic PIXE technique. Also the great advantage of simultaneously getting information about lighter elements and sample mass was reported to have been successfully employed in routine analyses. PIXE, which was initially considered to be a method mainly for thin samples, has also been shown to be competitive for a variety of thick samples. Data from aerosol studies was presented. With the PIXE-method, it is feasible to perform series of measurements over a long period of time, many samples in parallel and/or samples from sites of poor accessibility. However, the advantages of PIXE may be further exploited in aerosol investigations and some promising lines of sampler development were reported. Sample preparation techniques are crucial for applications to biological samples and several laboratories are engaged in such developmental work. However, it was also evident that PIXE is already giving significant contributions to research in biology and medicine

  13. Late Bronze Age hoard studied by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez Neira, P.C., E-mail: carolina.gutierrez@uam.es [CMAM, Universidad Autonoma de Madrid, c/Farady 3, E-28049 Madrid (Spain); Zucchiatti, A., E-mail: alessandro.zucchiatti@uam.es [CMAM, Universidad Autonoma de Madrid, c/Farady 3, E-28049 Madrid (Spain); Montero-Ruiz, I., E-mail: ignacio.montero@cchs.csic.es [CCHS-CSIC, Albasanz 26-28, E 28037 Madrid (Spain); Vilaca, R., E-mail: rvilaca@fl.uc.pt [University of Coimbra, Largo da Porta Ferrea, 3000-447 Coimbra (Portugal); Bottaini, C., E-mail: keret18@yahoo.it [University of Coimbra, Largo da Porta Ferrea, 3000-447 Coimbra (Portugal); Gener, M., E-mail: marc.gener@cchs.csic.es [CCHS-CSIC, Albasanz 26-28, E 28037 Madrid (Spain); Climent-Font, A., E-mail: acf@uam.es [CMAM, Universidad Autonoma de Madrid, c/Farady 3, E-28049 Madrid (Spain); Department of Applied Physics, Universidad Autonoma de Madrid, Campus Cantobalanco, E-28049 Madrid (Spain)

    2011-12-15

    The hoards of metallic objects belonging to the Late European Bronze Age can be interpreted differently depending on the type, number and composition of the artefacts. PIXE analysis has been performed in nine items from the Hoard of Freixanda in Portugal comprising four socket axes, a palstave axe, a ring, a chisel, a dagger, and a casting debris. Besides the composition of the main matrix elements, that is Cu and Sn, the amount of trace elements of interest like, As, Pb, Ni, and Ag has been determined using this ion beam technique. The high tin content alloy and the high purity of the metals from the Freixanda hoard are characteristic of the Portuguese and Spanish Late Bronze Age metallurgy, supporting the idea of a regional production.

  14. Enhanced identification of trace element fingerprint of prehistoric pigments by PIXE mapping

    Science.gov (United States)

    Lebon, M.; Pichon, L.; Beck, L.

    2018-02-01

    The elemental composition of Fe rich rocks used as pigment during prehistoric periods can provide valuable information about the type of material used and their geological origin. However, these materials present several analytical constraints since their patrimonial value involve using non-invasive techniques maintaining a high sensitivity of the detection and the quantification of trace elements. Micro-beam techniques also require to take into account the heterogeneity of these geomaterials from the macroscopic to microscopic scales. Several previous studies have demonstrated that PIXE analysis satisfies these analytical conditions. However, application of micro-PIXE analysis is still complex when thin and discontinuous layer of pigment is deposed on the surface of other materials such as rocks or bones. In such case, PIXE imaging could improve the ability to take into account the high heterogeneity of such archaeological objects. In study, we used PIXE imaging system developed at the NewAGLAE facility in order to visualize distribution of elements associated with iron-rich pigment phase. The results obtained show that PIXE maps can improve the identification of the main trace elements specific to the iron mineral phase. By grouping pixels of iron-rich areas and performing quantitative treatment, it was possible to reveal additional trace elements associated to pigment. This study highlights the contribution of PIXE imaging to the identification of elements associated with mineral phases of interest and to use them as proxies to discriminate different geological materials used in archaeological context.

  15. A PIXE mini-beam setup at the Bonn cyclotron for archeometric metal analyses

    International Nuclear Information System (INIS)

    Weber, J.; Beier, T.; Diehl, U.; Lambrecht, D.; Mommsen, H.; Pantenburg, F.J.

    1990-01-01

    The exact analysis of the elemental composition at and around a soldering joint of an antique piece of jewelry can elucidate the joining technologies and give hints of the genuineness of the object. As analytical method we use PIXE, which is nondestructive, multielemental and with fundamental parameter calculations gives absolute concentration values. To obtain the necessary spot size of the H 2 + beam at the Bonn cyclotron we use a piezo-controlled diaphragm, whose demagnified image is focussed on the target by two magnetic quadrupole triplets. With an electrostatic deflector the beam spot of 0.1x0.3 mm 2 size can be moved 2 mm in each direction on the target. With a laser beam, which simulates the ion beam, an irregularly shaped archeological object can be positioned. The laser is also used to obtain the alignment of the target surface to the ion beam direction and the small beam size makes it easier to find a flat part on the surface of the object; both of these are important preconditions for using the fundamental parameter method. A scan over a joint of modern gold alloys demonstrates the ability to detect soldering joints. The analysis of four pieces of Roman gold jewelry found in the area of Cologne and Bonn shows examples of brazing with a solder as well as diffusion soldering. (orig.)

  16. Electrostatic hazards

    CERN Document Server

    Luttgens, Günter; Luttgens, Gnter; Luttgens, G Nter

    1997-01-01

    In the US, UK and Europe there is in excess of one notifiable dust or electrostatic explosion every day of the year. This clearly makes the hazards associated with the handling of materials subject to either cause or react to electrostatic discharge of vital importance to anyone associated with their handling or industrial bulk use. This book provides a comprehensive guide to the dangers of static electricity and how to avoid them. It will prove invaluable to safety managers and professionals, as well as all personnel involved in the activities concerned, in the chemical, agricultural, pharmaceutical and petrochemical process industries. The book makes extended use of case studies to illustrate the principles being expounded, thereby making it far more open, accessible and attractive to the practitioner in industry than the highly theoretical texts which are also available. The authors have many years' experience in the area behind them, including the professional teaching of the content provided here. Günte...

  17. Electrostatic accelerators

    OpenAIRE

    Hinterberger, F

    2006-01-01

    The principle of electrostatic accelerators is presented. We consider Cockcroft– Walton, Van de Graaff and Tandem Van de Graaff accelerators. We resume high voltage generators such as cascade generators, Van de Graaff band generators, Pelletron generators, Laddertron generators and Dynamitron generators. The speci c features of accelerating tubes, ion optics and methods of voltage stabilization are described. We discuss the characteristic beam properties and the variety of possible beams. We ...

  18. Coupled electrostatic-elastic analysis for topology optimization using material interpolation

    International Nuclear Information System (INIS)

    Alwan, A; Ananthasuresh, G K

    2006-01-01

    In this paper, we present a novel analytical formulation for the coupled partial differential equations governing electrostatically actuated constrained elastic structures of inhomogeneous material composition. We also present a computationally efficient numerical framework for solving the coupled equations over a reference domain with a fixed finiteelement mesh. This serves two purposes: (i) a series of problems with varying geometries and piece-wise homogeneous and/or inhomogeneous material distribution can be solved with a single pre-processing step (ii) topology optimization methods can be easily implemented by interpolating the material at each point in the reference domain from a void to a dielectric or a conductor. This is attained by considering the steady-state electrical current conduction equation with a 'leaky capacitor' model instead of the usual electrostatic equation. This formulation is amenable for both static and transient problems in the elastic domain coupled with the quasi-electrostatic electric field. The procedure is numerically implemented on the COMSOL Multiphysics (registered) platform using the weak variational form of the governing equations. Examples have been presented to show the accuracy and versatility of the scheme. The accuracy of the scheme is validated for the special case of piece-wise homogeneous material in the limit of the leaky-capacitor model approaching the ideal case

  19. Finite Element Analysis and Lightweight Optimization Design on Main Frame Structure of Large Electrostatic Precipitator

    Directory of Open Access Journals (Sweden)

    Xuewen Wang

    2018-01-01

    Full Text Available The geometric modeling and finite element modeling of the whole structure of an electrostatic precipitator and its main components consisting of top beam, column, bottom beam, and bracket were finished. The strength calculation was completed. As a result, the design of the whole structure of the electrostatic precipitator and the main components were reasonable, the structure was in a balance state, its working condition was safe and reliable, its stress variation was even, and the stress distribution was regular. The maximum von Mises stress of the whole structure is 20.14 MPa. The safety factor was large, resulting in a waste of material. An optimization mathematical model is established. Using the ANSYS first-order method, the dimension parameters of the main frame structure of the electrostatic precipitator were optimized. After optimization, more reasonable structural design parameters were obtained. The model weight is 72,344.11 kg, the optimal weight is 49,239.35 kg, and the revised weight is 53,645.68 kg. Compared with the model weight, the optimal weight decreased by 23,104.76 kg and the objective function decreased by 31.94%, while the revised weight decreased by 18,698.43 kg and the objective function decreased by 25.84%.

  20. Discriminative study of white porcelains by INAA and PIXE

    International Nuclear Information System (INIS)

    Feng, X.Q.; Feng, S.L.; Meng, F.F.; Wang, H.M.; Liu, S.S.

    2005-01-01

    The fine white porcelains of Xing Kiln, Ding Kiln and Jingxing Kiln are very similar or alike in many aspects, such as typology of the vessel, texture of the body, colors of the body and the glaze. It is difficult for the archaeologists to distinguish the provenance using traditional methods. Nuclear analytical techniques (INAA, PIXE, XRF, SRXRF) have been widely employed for the provenance study of cultural relics in recent years due to their unique advantage, i.e. capable of nondestructive analysis. The element contents in the body and glaze of white porcelain shards with known provenance were determined by INAA and PIXE. In the meanwhile blind samples were prepared and analyzed in the same way. The differences of the element abundance patterns were processed by multivariate statistical analysis. On the basis of the analytical data and the statistical results, the discriminating criteria for provenance identification are obtained and verified by the blind samples.

  1. Development of a sample chamber for micro-PIXE

    International Nuclear Information System (INIS)

    Kurosawa, M.; Sueno, S.; Shima, K.; Ohshima, H.; Ishii, H.; Kamiya, H.; Kimoto, S.

    1997-01-01

    A new sample chamber for micro-PIXE analysis of geological thick samples has been successfully developed. A target in the sample chamber is normal to the beam and Si(Li) detectors are located at 135deg to the beam direction. For the sample observation, a normal viewing optics with the optical axis collinear with the beam is achieved by a combination of long working distance microscope and mirror with a central hole for the beam transmission. The normal incidence beam and normal viewing are essential to raise a spatial resolution of the thick target analysis. In addition, the sample chamber has fulfilled ten requirements as for material, driving stage, X-ray absorbers, space for another detector, etc. The information obtained by the development can give a new guide to manufacture the sample chamber for the micro-PIXE. (author)

  2. Environmental control of Tinto and Odiel river basins by PIXE

    International Nuclear Information System (INIS)

    Respaldiza, M.A.; Gomez-Camacho, J.; Lopez-Tarrida, A.J.

    1993-01-01

    A study of the elemental concentrations of sediments of the rivers Tinto and Odiel, in Huelva, Spain, has been performed using PIXE. Thirteen samples have been collected, seven in the Tinto and six in the Odiel. Concentrations of 19 elements have been determined in each of them. The analysis of the data illustrates the environmental impact of the mining and fertilizer plants in the area. (orig.)

  3. Chemical composition of a yellowish rainfall by the application of PIXE and micro-PIXE technique

    International Nuclear Information System (INIS)

    Ma, C.-J.

    2006-01-01

    Information of the chemical properties of rain fallen during the Asian dust (AD) event will help us to better understand the wet scavenging processes of dust particles. In this study, the chemical characteristics of rainwater and individual raindrops fallen during the AD storm have been investigated. The yellowish rainwater and individual raindrops were collected simultaneously in Kyoto, Japan on 7 April 2001. Particle induced X-ray emission (PIXE) was employed in the determination of chemical properties of soluble and insoluble fractions of rainwater. In addition, micro-PIXE was applied to the chemical analysis of residual materials retained in the initial individual raindrops. The pH level of yellowish rainwater was measured around 6.7. In compliance with the general expectation, major components in rainwater were of soil-origin such as Si, K, Ca, Ti and Fe. These soil-related components contributed to as much as 92% of total elemental composition in both soluble and insoluble fractions. By scanning a micro-beam, the residual particle cluster in individual raindrops was reconstructed in terms of an elemental map. This visualized elemental map in fact enabled us not only to estimate the chemical mixing state of raindrop residual particles but also to presume the wet scavenging of dust particles by rainfall

  4. Bio material resorption kinetics determination by global physical methods and gradient punctual analysis by P.I.X.E. nuclear method

    International Nuclear Information System (INIS)

    Braye, F.

    1994-07-01

    Substitution of tissue or human organ by biomaterials represents a problem, really hard, but which importance and interest justify all the efforts devoted which must also require a range of skills. In this work, we studied two produces of osseous substitution. One, the Coral, is a natural produce which interest, for such use, has been demonstrated in previous work executed in the bosom of our team. The other, the Hydroxyapatite, is a synthetic produce. Its presence in the form of micro crystal in human skeleton justifies its use for such purpose. Just after sterilization, natural Coral and synthetic Hydroxyapatite have been implanted in the femurs of sheep. Regularly, we used to extract the implants from the femurs to study the kinetics of elementary mineral transformation of both the osseous substitutes. For the first time and thanks to the PIXE Method (Particles Induced X-ray Emission), we had measured after implantation at different intervals all alone a cross section, the concentrations of mineral produces. The breakdown according to mineral elements (Ca, P, Sr, Zn, Fe) in the implant, in the receiver site and also at the interface, permitted to show that Kinetics of Coral resorption was faster than the one of Hydroxylapatite; in the same way, the osseous attack was not global but, on the contrary, centripetal. Concurrently, in accordance with time of implantation by spectrometry with atomic emission and inductive coupling, measurements of total concentrations proved the results of analyse through PIXE Method about kinetics of implant's resorption. Moreover, measurements by diffraction of X-rays and by neutronic radioactivation with thermal neutrons permitted respectively to make a satisfactory crystallographic verification of the specimens before and after sterilization. Finally, thanks to those measurements, it was possible to check if no potential contamination, caused by treatment or even by making of implants, was detected. (author). 49 refs., 35 tabs., 85

  5. Applications of PIXE to studies in dental and mental healths

    International Nuclear Information System (INIS)

    Chaudhri, M.A.; Melbourne Univ., Austin; Ainsworth, T.

    1981-01-01

    The elemental composition of healthy and diseased teeth from 25 South Australian children have been determined using thick target PIXE analysis. Different dental hard tissues, namely enamel, dentine, cementum and the amelodentinal junction, were analysed independently. A number of elements, Na, Mg, Al, P, S, Cl, Ca, V, Cr, Mn, Fe, Ni, Cu, Zn, Sr and Pb have been detected, and their concentrations measured. The concentrations of some of the elements were found to very considerable between: (a) healthy and diseases teeth, (b) teeth of the same type, and (c) different parts of the same tooth. Attemps have been made to correlate the concentrations of the various elements with the health of the teeth. In a pilot study, PIXE has also been applied for Pb analysis in the teeth of a few mentally retarded children. The teeth of all the children, with the exception of one who was suffering from Downe's syndrome, were found to contain appreciable amounts of lead. It is suggested that PIXE would provide a more convenient and accurate form of analysis than destructive chemical methods, for correlation Pb in children's teeth with their mental abilities. (orig.)

  6. A study with microbeam PIXE technique needed for the interpretation of data on pollutants in hair obtained with NAA and other bulk concentration analysis. Part of a coordinated programme on nuclear-based methods for analysis of pollutants in human hair

    International Nuclear Information System (INIS)

    Houtman, J.P.W.

    1981-01-01

    Hair metals the analysis of which has been proposed as a practical method for assaying human contamination with metal pollutants, reflect both internal and external contamination. This study is an attempt to distinguish these two components of hair metals, using the scanning microbeam PIXE technique. Individual hair strands were embedded in a resin combined with a hardener. Each embedded hair strand was cut perpendicular to its axis, into the root, 1-cm and 2-cm segments from the root. The 3 segments were analysed for few elements including As and Pb, using the scanning microbeam PIXE technique. For each segment, a proton microbeam of 15μ diameter and 500Hz frequency was used to scan the segment cross-section along the long axis. X-ray spectrometry was used to determine the concentrations of the elements studied. The results, although preliminary, showed that the scanning microbeam PIXE technique may provide important information about elemental concentrations and distribution patterns along hair length and hair cross-section. This may lead to a better understanding of mechanisms responsible for the deposition of elements into hair and thereby to a more rational use of hair analysis as a method for assaying human exposure to element pollutants

  7. Micro-PIXE studies of char populations in northern Canada

    International Nuclear Information System (INIS)

    Campbell, J.L.; Babaluk, J.A.; Halden, N.M.; Kristofferson, A.H.; Maxwell, J.A.; Mejia, S.R.; Reist, J.D.; Teesdale, W.J.

    1999-01-01

    Micro-PIXE analysis of trace elements in otoliths has been used as the basis for several projects on char, a fish that is important for aboriginal subsistence fisheries in Arctic Canada. Life-history patterns were originally inferred from micro-PIXE line scans of Sr distribution. These were confirmed by superposition of Sr distribution patterns on optical images of otoliths of tag-recaptured fish. Char from various populations showed differentiation in otolith primordial Sr concentration; this enables us to differentiate biological stocks and, it is hoped, eventually to assign individuals from mixed-stock fisheries to their stock of origin. Zn oscillations also correlate with annular structure and provide additional temporally constrained information on fish habitat and behaviour

  8. PIXE study on arsenic accumulation by a fern. Pteris vittata

    International Nuclear Information System (INIS)

    Yamazaki, H.; Ishii, K.; Matsuyama, S.

    2010-01-01

    Pteris vittata is a fern reported to be an arsenic hyper-accumulator. To develop the practical application of the fern to a phytoremediation technique, it is necessary to explicate the effective accumulation mechanism. In this study, the arsenic distribution and the elemental correlation in the cellular level were examined in the fronds supplied with arsenate and arsenite separately via xylem vessel using an in-air micro-PIXE system at Tohoku University. The difference in transportation rate between arsenate and arsenite as well as the translocation of elements necessary for plant metabolism was revealed in different tissues of the fronds accumulating arsenic in high concentration. Hence, the in-air micro-PIXE analysis is an effective measure for undertaking phytoremediation research of hyper-accumulator plants. (author)

  9. Air pollution studies using PIXE and ICP methods

    International Nuclear Information System (INIS)

    Stihi, Claudia; Bancuta, Anca; Popescu, I V; Virgolici, M; Cimpoca, V; Gugiu, M; Vlaicu, Gh

    2006-01-01

    In the present work the moss biomonitoring technique and the combination of two analytical techniques - Particle Induced X-ray Emission (PIXE) and Inductively Coupled Plasma (ICP) - were applied for assessing environmental situation from the point of view of air polluting along the transect from north to south of the Dambovita County. PIXE analysis at the Tandem Accelerator FN-8 of the National Institute of Nuclear Physics - Horia Hulubei of Magurele, Bucharest, allowed determination of P, S, Cl, K, Ca, Mn, Fe, Ni, Cu, Zn, As, Sr, Cd and Pb in samples. ICP analyses were made using a Baird ICP2070 - Sequential Plasma Spectrometer in Targoviste and we determined in samples the concentration of Li, B, Na, and Mg together with Cd and Pb. The obtained results will permit to determine the regional extent of heavy metals and toxic elements atmospheric pollution and to identify specially affected areas and local sources of

  10. Standard addition strip for quantitative electrostatic spray ionization mass spectrometry analysis: determination of caffeine in drinks.

    Science.gov (United States)

    Tobolkina, Elena; Qiao, Liang; Roussel, Christophe; Girault, Hubert H

    2014-12-01

    Standard addition strips were prepared for the quantitative determination of caffeine in different beverages by electrostatic spray ionization mass spectrometry (ESTASI-MS). The gist of this approach is to dry spots of caffeine solutions with different concentrations on a polymer strip, then to deposit a drop of sample mixed with an internal standard, here theobromine on each spot and to measure the mass spectrometry signals of caffeine and theobromine by ESTASI-MS. This strip approach is very convenient and provides quantitative analyses as accurate as the classical standard addition method by MS or liquid chromatography. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Trajectory Analysis of Copper and Glass Particles in Electrostatic Separation for the Recycling of ASR

    Directory of Open Access Journals (Sweden)

    Beom-uk Kim

    2017-10-01

    Full Text Available Automobile-shredder-residue (ASR recycling techniques have been widely applied for improving the total recycling rate of end-of-life vehicles. In this study, to obtain useful information for predicting or improving ASR-separation efficiency, trajectory analyses of conductors (copper and non-conductors (glass were performed using a lab-scale induction electrostatic separator. The copper-wire trajectories obtained showed a good agreement depending significantly on the electric field strength and particle size. The observed copper-wire trajectories showed consistent congruity with the coarse-particles simulation (0.5 and 0.25 mm. The observed fine-particles (0.06 mm trajectory was deflected toward the (− attractive electrode, owing to the charge density effects due to the particle characteristics and relative humidity. This results in superior separation performance because more copper enters the conductor products bin. The actual dielectric-glass trajectory was deflected toward the (− attractive electrode, thus showing characteristics similar to conductive-particle characteristics. Through analyses conducted using a stereoscopic microscope, scanning electron microscope, and energy dispersive spectroscope, we found heterogeneous materials (fine ferrous particles and conductive organics on the glass surface. This demonstrates the separation-efficiency decrease for non-ferrous metals during electrostatic separation in the recycling of ASR. Future work should include a pretreatment process for eliminating impurities from the glass and advanced trajectory-simulation processes.

  12. Validation and analysis of the coupled multiple response Colorado upper-division electrostatics diagnostic

    Directory of Open Access Journals (Sweden)

    Bethany R. Wilcox

    2015-11-01

    Full Text Available Standardized conceptual assessment represents a widely used tool for educational researchers interested in student learning within the standard undergraduate physics curriculum. For example, these assessments are often used to measure student learning across educational contexts and instructional strategies. However, to support the large-scale implementation often required for cross-institutional testing, it is necessary for these instruments to have question formats that facilitate easy grading. Previously, we created a multiple-response version of an existing, validated, upper-division electrostatics diagnostic with the goal of increasing the instrument’s potential for large-scale implementation. Here, we report on the validity and reliability of this new version as an independent instrument. These findings establish the validity of the multiple-response version as measured by multiple test statistics including item difficulty, item discrimination, and internal consistency. Moreover, we demonstrate that the majority of student responses to the new version are internally consistent even when they are incorrect and provide an example of how the new format can be used to gain insight into student difficulties with specific content in electrostatics.

  13. Analytical Methods INAA and PIXE Applied to Characterization of Airborne Particulate Matter in Bandung, Indonesia

    Directory of Open Access Journals (Sweden)

    D.D. Lestiani

    2011-08-01

    Full Text Available Urbanization and industrial growth have deteriorated air quality and are major cause to air pollution. Air pollution through fine and ultra-fine particles is a serious threat to human health. The source of air pollution must be known quantitatively by elemental characterization, in order to design the appropriate air quality management. The suitable methods for analysis the airborne particulate matter such as nuclear analytical techniques are hardly needed to solve the air pollution problem. The objectives of this study are to apply the nuclear analytical techniques to airborne particulate samples collected in Bandung, to assess the accuracy and to ensure the reliable of analytical results through the comparison of instrumental neutron activation analysis (INAA and particles induced X-ray emission (PIXE. Particle samples in the PM2.5 and PM2.5-10 ranges have been collected in Bandung twice a week for 24 hours using a Gent stacked filter unit. The result showed that generally there was a systematic difference between INAA and PIXE results, which the values obtained by PIXE were lower than values determined by INAA. INAA is generally more sensitive and reliable than PIXE for Na, Al, Cl, V, Mn, Fe, Br and I, therefore INAA data are preffered, while PIXE usually gives better precision than INAA for Mg, K, Ca, Ti and Zn. Nevertheless, both techniques provide reliable results and complement to each other. INAA is still a prospective method, while PIXE with the special capabilities is a promising tool that could contribute and complement the lack of NAA in determination of lead, sulphur and silicon. The combination of INAA and PIXE can advantageously be used in air pollution studies to extend the number of important elements measured as key elements in source apportionment.

  14. Analytical Methods INAA and PIXE Applied to Characterization of Airborne Particulate Matter in Bandung, Indonesia

    International Nuclear Information System (INIS)

    Lestiani, D.D.; Santoso, M.

    2011-01-01

    Urbanization and industrial growth have deteriorated air quality and are major cause to air pollution. Air pollution through fine and ultra-fine particles is a serious threat to human health. The source of air pollution must be known quantitatively by elemental characterization, in order to design the appropriate air quality management. The suitable methods for analysis the airborne particulate matter such as nuclear analytical techniques are hardly needed to solve the air pollution problem. The objectives of this study are to apply the nuclear analytical techniques to airborne particulate samples collected in Bandung, to assess the accuracy and to ensure the reliable of analytical results through the comparison of instrumental neutron activation analysis (INAA) and particles induced X-ray emission (PIXE). Particle samples in the PM 2.5 and PM 2.5-10 ranges have been collected in Bandung twice a week for 24 hours using a Gent stacked filter unit. The result showed that generally there was a systematic difference between INAA and PIXE results, which the values obtained by PIXE were lower than values determined by INAA. INAA is generally more sensitive and reliable than PIXE for Na, Al, Cl, V, Mn, Fe, Br and I, therefore INAA data are preferred, while PIXE usually gives better precision than INAA for Mg, K, Ca, Ti and Zn. Nevertheless, both techniques provide reliable results and complement to each other. INAA is still a prospective method, while PIXE with the special capabilities is a promising tool that could contribute and complement the lack of NAA in determination of lead, sulphur and silicon. The combination of INAA and PIXE can advantageously be used in air pollution studies to extend the number of important elements measured as key elements in source apportionment. (author)

  15. Fatigue Durability Analysis of Collecting Rapping System in Electrostatic Precipitators under Impact Loading

    Directory of Open Access Journals (Sweden)

    Ali Akbar Lotfi Neyestanak

    2014-01-01

    Full Text Available Due to the importance of collecting rapping system in electrostatic precipitators (ESP and controlling the relevant damage under impact loading, fatigue durability of this system is analyzed in the present study based on the numerical and experimental results considering fatigue damage growth and vibration acceleration in the collecting system because of the successive impact of rapping hammers. By microscopic examination of the fracture surface of rapping hammer, beach marks obviously show typical fatigue failure in the rapping hammer arm. In addition, the microscopic examination of the cross section of the collecting plates indicates the corrosion voids which cause crack and eventually fatigue failure. The finite element method is applied to determine both the stress and concentration positions of dynamic stress on the rapping system under impact loading. The paper results can be utilized in system optimization and new material selection for the system by evaluating rapping system durability.

  16. Finite element analysis on factors influencing the clamping force in an electrostatic chuck

    International Nuclear Information System (INIS)

    Wang Xingkuo; Yang Yiyong; Cheng Jia; Wang Kesheng; Sun Yuchun; Cao Minglu; Ji Linhong

    2014-01-01

    As one of the core components of IC manufacturing equipment, the electrostatic chuck (ESC) has been widely applied in semiconductor processing such as etching, PVD and CVD. The clamping force of the ESC is one of the most important technical indicators. A multi-physics simulation software COMSOL is used to analyze the factors influencing the clamping force. The curves between the clamping force and the main parameters such as DC voltage, electrode thickness, electrode radius, dielectric thickness and helium gap are obtained. Moreover, the effects of these factors on the clamping force are investigated by means of orthogonal experiments. The results show that the factors can be ranked in order of voltage, electrode radius, helium gap and dielectric thickness according to their importance, which may offer certain reference for the design of ESCs. (semiconductor devices)

  17. PIXE analysis showed that the preirradiation enhanced recovery of bone marrow elements after challenging irradiation in C57BL/6N Mice

    International Nuclear Information System (INIS)

    Matsuda, Y.; Yonezawa, M.; Nishiyama, F.

    2000-01-01

    Priming X-irradiation with 0.3-0.5 Gy induces radio-resistance in C57BL/6 strain of mice 2 weeks afterward. Elements in the bone marrow, sampled 11 days after challenging exposure to 5.0 Gy, were determined by PIXE. The challenging irradiation decreased Mg, P, S, K, Ca and Zn as well as dried bone marrow weight. The pre-irradiation enhanced recovery of these levels, indicating stimulated recovery of the metabolism int he tissue. Fe in both control (without pre-irradiation) and experimental groups increased to about twice the original value, showing elevated hemoglobin synthesis after challenging exposure. In previous studies we have reported that recovery of peripheral blood cell counts after sub-lethal irradiation was enhanced by the pre-irradiation. Further, study on accumulation of p53 and Bax proteins, which lead to apoptotic cell death, revealed that the pre-irradiation significantly suppressed accumulation of these proteins in the spleen after challenging irradiation with 3 Gy. These results and our present study suggest that the pre-irradiation decreased the spleen cell death, and favored re-growth of the spleen cells, resulting in stimulated recovery of metabolism for hematopoiesis in the bone marrow as well as in the spleen after challenging high dose irradiation. Stimulated recovery of Mg, P, S, K, Ca and Zn levels might indicate the importance of these elements in hematopoiesis. (author)

  18. Applications of external PIXE to ancient Egyptian artefacts

    International Nuclear Information System (INIS)

    Moser, M.; Bubb, I.F.; Johnston, N.; El Bouanani, M.; Stannard, W.B.; Short, R.C.

    1998-01-01

    The external Proton Induced X-Ray Emission (PIXE) facility at Royal Melbourne Institute of Technology has been used to analyse ancient Egyptian glass samples, an Egyptian wall paint fragment and soil pigments. A 0.35 mm diameter beam of 1.6 MeV protons, extracted from the vacuum through an 8 μm gold coated Kapton foil was used. Analysis of the spectra was carried out with the analysis package PIXAN. The analysis of two Egyptian glass samples enabled the partial determination of the colouring transition metals and the manufacturing technique, indicating them to be consistent with 'New Kingdom' glasses

  19. 3D Micro-PIXE at atmospheric pressure: A new tool for the investigation of art and archaeological objects

    International Nuclear Information System (INIS)

    Kanngiesser, Birgit; Karydas, Andreas-Germanos; Schuetz, Roman; Sokaras, Dimosthenis; Reiche, Ina; Roehrs, Stefan; Pichon, Laurent; Salomon, Joseph

    2007-01-01

    The paper describes a novel experiment characterized by the development of a confocal geometry in an external Micro-PIXE set-up. The position of X-ray optics in front of the X-ray detector and its proper alignment with respect to the proton micro-beam focus provided the possibility of carrying out 3D Micro-PIXE analysis. As a first application, depth intensity profiles of the major elements that compose the patina layer of a quaternary bronze alloy were measured. A simulation approach of the 3D Micro-PIXE data deduced elemental concentration profiles in rather good agreement with corresponding results obtained by electron probe micro-analysis from a cross-sectioned patina sample. With its non-destructive and depth-resolving properties, as well as its feasibility in atmospheric pressure, 3D Micro-PIXE seems especially suited for investigations in the field of cultural heritage

  20. Dispersive FDTD analysis of induced electric field in human models due to electrostatic discharge.

    Science.gov (United States)

    Hirata, Akimasa; Nagai, Toshihiro; Koyama, Teruyoshi; Hattori, Junya; Chan, Kwok Hung; Kavet, Robert

    2012-07-07

    Contact currents flow from/into a charged human body when touching a grounded conductive object. An electrostatic discharge (ESD) or spark may occur just before contact or upon release. The current may stimulate muscles and peripheral nerves. In order to clarify the difference in the induced electric field between different sized human models, the in-situ electric fields were computed in anatomically based models of adults and a child for a contact current in a human body following ESD. A dispersive finite-difference time-domain method was used, in which biological tissue is assumed to obey a four-pole Debye model. From our computational results, the first peak of the discharge current was almost identical across adult and child models. The decay of the induced current in the child was also faster due mainly to its smaller body capacitance compared to the adult models. The induced electric fields in the forefingers were comparable across different models. However, the electric field induced in the arm of the child model was found to be greater than that in the adult models primarily because of its smaller cross-sectional area. The tendency for greater doses in the child has also been reported for power frequency sinusoidal contact current exposures as reported by other investigators.

  1. Dispersive FDTD analysis of induced electric field in human models due to electrostatic discharge

    International Nuclear Information System (INIS)

    Hirata, Akimasa; Nagai, Toshihiro; Koyama, Teruyoshi; Hattori, Junya; Chan, Kwok Hung; Kavet, Robert

    2012-01-01

    Contact currents flow from/into a charged human body when touching a grounded conductive object. An electrostatic discharge (ESD) or spark may occur just before contact or upon release. The current may stimulate muscles and peripheral nerves. In order to clarify the difference in the induced electric field between different sized human models, the in-situ electric fields were computed in anatomically based models of adults and a child for a contact current in a human body following ESD. A dispersive finite-difference time-domain method was used, in which biological tissue is assumed to obey a four-pole Debye model. From our computational results, the first peak of the discharge current was almost identical across adult and child models. The decay of the induced current in the child was also faster due mainly to its smaller body capacitance compared to the adult models. The induced electric fields in the forefingers were comparable across different models. However, the electric field induced in the arm of the child model was found to be greater than that in the adult models primarily because of its smaller cross-sectional area. The tendency for greater doses in the child has also been reported for power frequency sinusoidal contact current exposures as reported by other investigators. (paper)

  2. Multi-elemental analysis of atmospheric pollutants and determination of particle size using the PIXE method, a cascade impactor and a filter unit constructed in Mexico; Analisis multielemental de contaminantes atmosfericos y determinacion de tamano de particula utilizando el metodo PIXE, un impactor de cascada y una unidad de filtro construidos en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Aldape U, F [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1989-01-15

    This work presents: 1) The methodology and the experimental conditions of the PIXE technique so that it is used as a better option inside the analytical methods in aerosols studies, 2) The development, tests and applications of a cascade impactor of the Batelle type built to determine particle size to use it jointly with the mentioned technique in the determination of the elements concentration according to its size.By this way is fulfilled with the first goal of this extensive project. (Author)

  3. Detection and quantitative determination by PIXE of the mutagen Sn2+ in yeast cells

    International Nuclear Information System (INIS)

    Viau, C.M.; Yoneama, M.-L.; Dias, J.F.; Pungartnik, C.; Brendel, M.; Henriques, J.A.P.

    2006-01-01

    The main goal of this work was to determine the concentration of Sn 2+ ions in cells of the yeast Saccharomyces cerevisiae and to correlate their quantity with the genotoxicity of intracellularly accumulated metal ions. The intracellular metal content of yeast cells was determined by PIXE (particle-induced X-ray emission) after cell exposure to SnCl 2 . To that end, a thick target protocol was developed for PIXE analysis. The samples were irradiated with a 2 MeV proton beam, while the induced X-rays were detected with a high-purity germanium detector. The results of the toxicity of SnCl 2 and the PIXE analysis performed with two different yeast strains (haploid and diploid) suggest that the exposure of haploid and diploid yeast to Sn 2+ induces DNA lesions and that the absorption depends on the genetic background of each strain

  4. LibCPIXE: A PIXE simulation open-source library for multilayered samples

    International Nuclear Information System (INIS)

    Pascual-Izarra, C.; Barradas, N.P.; Reis, M.A.

    2006-01-01

    Most particle induced X-ray emission (PIXE) data analysis codes are not focused on handling multilayered samples. We have developed an open-source library called 'LibCPIXE', for PIXE data analysis. It is written in standard C and implements functions for simulating X-ray yields of PIXE spectra taken from arbitrary samples, including multilayered targets. The library is designed to be fast, portable, modular and scalable, as well as to facilitate its incorporation into any existing program. In order to demonstrate the capabilities of the library, a program called CPIXE was developed and used to analyze various real samples involving both bulk and layered samples. Just as the library, the CPIXE source code is freely available under the General Public License. We demonstrate that it runs both under GNU/Linux systems as well as under MS Windows. There is in principle no limitation to port it to other platforms

  5. Electrostatic curtain studies

    International Nuclear Information System (INIS)

    Meyer, L.C.

    1992-05-01

    This report presents the results of experiments using electrostatic curtains (ESCS) as a transuranic (TRU) contamination control technique. The TRU contaminants included small (micrometer to sub micrometer) particles of plutonium and americium compounds associated with defense-related waste. Three series of experiments were conducted. The first was with uncontaminated Idaho National Engineering Laboratory (INEL) soil, the second used contaminated soil containing plutonium-239 (from a mixture of Rocky Flats Plant contaminated soil and INEL uncontaminated soil), and the third was uncontaminated INEL soil spiked with plutonium-239. All experiments with contaminated soil were conducted inside a glove box containing a dust generator, low volume cascade impactor (LVCI), electrostatic separator, and electrostatic materials. The data for these experiments consisted of the mass of dust collected on the various material coupons, plates, and filters; radiochemical analysis of selected samples; and photographs, as well as computer printouts giving particle size distributions and dimensions from the scanning electron microscope (SEM). The following results were found: (a) plutonium content (pCi/g) was found to increase with smaller soil particle sizes and (b) the electrostatic field had a stronger influence on smaller particle sizes compared to larger particle sizes. The SEM analysis indicated that the particle size of the tracer Pu239 used in the spiked soil experiments was below the detectable size limit (0.5 μm) of the SEM and, thus, may not be representative of plutonium particles found in defense-related waste. The use of radiochemical analysis indicated that plutonium could be found on separator plates of both polarities, as well as passing through the electric field and collecting on LVCI filters

  6. PIXE determination of Pb in wine

    Energy Technology Data Exchange (ETDEWEB)

    Kocsonya, A.; Guguianu, O.; Demeter, I.; Hollos-Nagy, Katalin; Kovacs, I.; Szokefalvi-Nagy, Z. E-mail: sznagy@rmki.kfki.hu

    2002-04-01

    The permissible level of the Pb content in wine varies in the range of 200-300 {mu}g/l in different countries. These values are below the detection limit for standard PIXE spectrometry. Initiated by an intercomparison action of The International Measurement Evaluation Programme (IMEP, Geel, Belgium), an attempt was made to lower the detection limit of PIXE without introducing any additional chemical steps. Wine samples of 5 ml were gradually condensed below an infrared lamp and 8 {mu}l aliquots were taken from time to time and pipetted onto filter paper. The samples were analysed by standard PIXE technique, with the analyte addition method used for calibration. A detection limit of about 50 ppb was finally achieved. Comparing this value to the permissible levels, this simple and fast technique can be used for screening purposes. As an application, the lead content of three Hungarian market wines was also measured.

  7. PIXE determination of Pb in wine

    International Nuclear Information System (INIS)

    Kocsonya, A.; Guguianu, O.; Demeter, I.; Hollos-Nagy, Katalin; Kovacs, I.; Szokefalvi-Nagy, Z.

    2002-01-01

    The permissible level of the Pb content in wine varies in the range of 200-300 μg/l in different countries. These values are below the detection limit for standard PIXE spectrometry. Initiated by an intercomparison action of The International Measurement Evaluation Programme (IMEP, Geel, Belgium), an attempt was made to lower the detection limit of PIXE without introducing any additional chemical steps. Wine samples of 5 ml were gradually condensed below an infrared lamp and 8 μl aliquots were taken from time to time and pipetted onto filter paper. The samples were analysed by standard PIXE technique, with the analyte addition method used for calibration. A detection limit of about 50 ppb was finally achieved. Comparing this value to the permissible levels, this simple and fast technique can be used for screening purposes. As an application, the lead content of three Hungarian market wines was also measured

  8. Studies of prehistoric flint tools by PIXE

    International Nuclear Information System (INIS)

    Smit, Z.

    2002-01-01

    The trace elements preserved on sharp edges of stone tools may provide some information about the worked material, which in turn may serve for the reconstruction of users way of life. Since the amount of the deposited worked material is minute, it can only be detected by sensitive fluorescence techniques, induced by electrons in the electron microscopes, or by light ions from the particle accelerators (PIXE). The trace element deposition was studied by PIXE for a set of experimental tools used for working bone and wood, and for a set of archaeological artefacts dating from the late paleolithic till neolithic period. (author)

  9. PIXE technique use for urban aerosol characterization

    International Nuclear Information System (INIS)

    Dias da Cunha, K.; Lazarra, M.; Nazare, R.A.; D'Oliveira, D.; Barros Leite, C.V.

    1996-01-01

    A cascade impactor and PIXE technique were used to estimate the air pollution in a urban area. PIXE is a multielementar method and for all elements the detection limit is about nanograms. The particle size distribution was determined using a cascade impactor with six stage. It collects the particles in the respirable and invaluable of aerosol. The samples were collected close to Planetary in Rio de Janeiro City. The results indicate that particles containing Cu, Zn, Ni, Fe, Mn, Cr, V, Ti, Ca and K. The particle was in the respirable fraction of with MMAD,2 μm. (author)

  10. Particle induced x-ray emission (PIXE) measurement of the Cd content in animal tissues

    International Nuclear Information System (INIS)

    Le Huong Quynh; Demeter, I.; Hollos-Nagy, K.; Szoekefalvi-Nagy, Z.

    1989-12-01

    Particle induced x-ray emission (PIXE) measurements were performed on thin samples prepared from different rabbit tissues, using 3 MeV proton beam for inducing x-rays from the animal tissues. This method is very sensitive and very small amounts of trace elements can be detected. Cadmium, one of the most toxic elements which can be concentrated in animal and human tissues due to environmental pollution, was detected with a limit of 0.7 ppm. The trace element concentrations obtained by PIXE were compared to those measured by atomic absorption spectrometry. PIXE method is proposed for routine analysis at the Veterinary and Food Investigating Service, Budapest, Hungary. (D.Gy.) 6 refs.; 3 figs

  11. Trace elements in lake sediments measured by the PIXE technique

    International Nuclear Information System (INIS)

    Gatti, Luciana V.; Mozeto, Antonio A.; Artaxo, Paulo

    1999-01-01

    Lakes are ecosystems where there is a great potential of metal accumulation in sediments due to their depositional characteristics. Total concentration of trace elements was measured on a 50 cm long sediment core from the Infernao Lake, that is an oxbow lake of the Moji-Guacu River basin, in the state of Sao Paulo, Brazil. Dating of the core shows up to 180 yrs old sediment layers. The use of the PIXE technique for elemental analysis avoids the traditional acid digestion procedure common in other techniques. The multielemental characteristic of PIXE allows a simultaneous determination of about 20 elements in the sediment samples, such as, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Rb, Sr, Zr, Ba, and Pb. Average values for the elemental composition were found to be similar to the bulk crustal composition. The lake flooding pattern strongly influences the time series of the elemental profiles. Factor analysis of the elemental variability shows five factors. Two of the factors represent the mineralogical matrix, and others represent the organic component, a factor with lead, and another loaded with chromium. The mineralogical component consists of elements such as, Fe, Al, V, Ti, Mn, Ni, K, Zr, Sr, Cu and Zn. The variability of Si is explained by two distinct factors, because it is influenced by two different sources, aluminum-silicates and quartz, and the effect of inundation are different for each other. The organic matter is strongly associated with calcium, and also bounded with S, Zn, Cu and P. Lead and chromium appears as separated factors, although it is not clear the evidences for their anthropogenic origin. The techniques developed for sample preparation and PIXE analysis was proven as advantageous and provided very good reproducibility and accuracy

  12. Trace metal content in aspirin and women's cosmetics via proton induced x-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Hichwa, B.P.; Pun, D.D.; Wang, D.

    1981-01-01

    A multielemental analysis to determine the trace metal content of generic and name-brand aspirins and name-brand lipsticks was done via proton induced x-ray (PIXE) measurements. The Hope College PIXE system is described as well as the target preparation methods. The trace metal content of twelve brands of aspirin and aspirin substitutes and fourteen brands of lipstick are reported. Detection limits for most elements are in the range of 100 parts per billion (ppb) to 10 parts per million

  13. Mapping of heavy metals accumulated in plants using submilli-pixe camera

    International Nuclear Information System (INIS)

    Watanabe, R.; Hara, J.; Inoue, C.; Chida, T.; Amartaivan, TS.; Matsuyama, S.; Yamazaki, H.; Ishii, K.

    2004-01-01

    Phytoremediation is a technology for remediation of contaminated soils. In this study, we used a submilli-PIXE camera to analyze plants and soils from a shooting range. Some heavy metals were rapidly and easily detected in these samples. Element dot-maps of the plant show Cu and Pb accumulated in the epidermis of subterranean stems and the venation of leaves. From these findings, it is possible to map the distribution of heavy metals and to detail their location in the plant, using the submilli-PIXE analysis is an effective tool for undertaking phytoremediation research. (author)

  14. Trace element finger printing of emeralds by PIXE and PIGE

    International Nuclear Information System (INIS)

    Ma Xinpei; Palmer, G.R.; MacArthur, J.D.

    1990-01-01

    The concentrations of 18 major- and minor-elements in 12 Emeralds from different mines and two synthetic ones are measured with proton induced X-ray emission (PIXE) and γ-ray emission (PIGE). The concentration and distribution of 18 elements are used to establish the characteristic finger print pattern of each Emerald. With the help of cluster analysis of SYSTAT statistical package for IBMPC, these finger prints are analysed, from which a quantitative description of the dissimilarities between Emeralds can be given

  15. Micro-PIXE in plant sciences

    International Nuclear Information System (INIS)

    Mesjasz-Przybylowicz, J.; Przybylowicz, W.J.

    2013-01-01

    Full text: Studies of the role played by elements in fundamental processes in physiology, nutrition, elemental deficiency and toxicity as well as environmental pollution require accurate, quantitative methods with good spatial resolution. the problem of proper measurements of elemental balances and elemental transfers between various levels of biological organisation (from abiotic to biotic systems; along the food chains; within organs and cells) becomes essential for understanding the mechanisms influencing the selection, interaction, distribution and transport of elements. Highly sensitive techniques for bulk elemental analysis are mostly used in these investigations. These techniques usually offer adequate sensitivity, but without spatial resolution. On the other hand, advanced studies of elemental distribution at a cellular level are mostly conducted using techniques with high spatial resolution, but low sensitivity. Ideally, these studies should be conducted on organs and tissues of sizes as far down as the cellular and sub-cellular level. This applies to e.g. future directions in ionomics and metallomics and opens up new, exciting possibilities of studies of trace metal role. The micro-PIXE has been applied in plant sciences for more than thirty years and has reached a high level of maturity. This is one of the few microanalytical, multielemental techniques capable of quantitative studies of elemental distribution at ppm level with with ability to perform quantitative elemental mapping and easy quantification of data extracted from selected micro-areas. Preparation of biological specimens is undoubtedly the crucial and most difficult part of analysis, and only cryotechniques are recommended presently for ali types of microanalytical studies. Established sample preparation protocols will be presented. Most of results are obtained for cryofixed and freeze-dried material but analysis of samples in frozen-hydrated state brings important advantage. Recent

  16. Particle induced X-ray emission (PIXE) present and future. Ryushisen reiki X sen bunsekiho (PIXE) no genjo to shorai

    Energy Technology Data Exchange (ETDEWEB)

    Uda, M. (Waseda Univ., Tokyo (Japan). Science and Engineering)

    1992-07-10

    The principle of measurement of PIXE are explained. It has in comparison with SEM and EPM, the following characteristics such as; very short measurement and analysis time, developed detection sensitivity for more than 100 elements, no need of pretreatment, undestructive analysis method in the air, possibility of trace element analysis by using micro specimen and information input of chemical bonding condition. Bio-medical applications have been, the microanalysis of multi elements in light element matrix forming living body and the diagnosis of kidney cancer and other diseases. Environmental applications have been, detection of the composition of sea water and the detection of the pollutants of the rivers by elements concentration distribution. It is also applied for managing the amount of impurities in electronic materials and monitoring the emitted elements from fusion reactor. It is used for archaeological analysis such as, analysis of gold fixing in ancient Rome and earthernware analysis of ancient China. As for the chemical bonding condition, the small difference of chemical bonding has been able to be observed clearly as a difference of strength over the multiple spectra, and PIXE has prospects in multiple fields. 24 refs., 21 figs.

  17. TXRF, PIXE, SYXRF; principles, critical comparison and applications

    International Nuclear Information System (INIS)

    Knoechel, A.

    1990-01-01

    At first glance X-Ray fluorescence analysis seems to be a very sensitive and effectful method to detect element traces in the multielement mode. But in praxi the application range is restricted, if X-Ray tubes are used as excitation sources. To overcome this situation, it is necessary to improve the conditions of excitation and to reduce the background, produced by different scattering effects. TXRF, PIXE and SYXRF, which allow multielement analysis in the trace- and ultratrace region are using this strategy. In the case of TXRF a remarkable background reduction is achieved if the sample is prepared as a thin amorphous film on a planar sample holder and the excitation beam of a X-Ray tube is totally reflected on its surface. In the case of PIXE a particle beam of high intensity is used as excitation source, improving the conditions of excitation and giving the opportunity of spatial resolved analyses. In the case of SYXRF the X-Ray fraction of synchrotron radiation is used as excitation source, giving the opportunity, to improve the conditions of excitation as well as to reduce the background by using the high polarisation of the beam. In this case, too, spatial resolved analysis are possible. The principles of the three methods are described, their advantages and disadvantages are critically compared and advanced applications from different analytical fields are presented. (orig.)

  18. Micro-PIXE in plant sciences: Present status and perspectives

    International Nuclear Information System (INIS)

    Mesjasz-Przybylowicz, Jolanta; Przybylowicz, Wojciech J.

    2002-01-01

    Fundamental processes of plant physiology are affected or regulated by mineral nutrients. Hence understanding the mechanisms of nutrient uptake and their functions in plant metabolism is of fundamental importance in both basic and applied plant studies. The present knowledge of ion uptake mechanisms is based mostly on techniques for bulk analysis, including analysis of small (mg-sized) samples but without spatially resolved results. On the other hand, advanced studies of elemental transport at a cellular level are conducted using techniques with high and very high spatial resolution, but with low sensitivity for elemental analysis. Thus the results obtained are usually restricted to macronutrients or elements present in high quantities. There is a high demand for studies of the functions of trace elements. In addition, it is known that, depending on their concentrations, elements can play different roles in plant life. Studies related to elemental deficiency and toxicity, as well as environmental pollution, require accurate, fully quantitative methods with good spatial resolution. Ideally, these studies should be conducted on organs and tissues as far down as the cellular level. This is where micro-PIXE has been applied until present and can in the near future play a much more important role. Progress is subject to closer collaboration between plant biologists and the PIXE community in terms of addressing problems of specimen preparation, refinement of analytical protocols such as quantitative elemental mapping and the interpretation of results

  19. Electrostatic accelerator dielectrics

    International Nuclear Information System (INIS)

    Cooke, C.M.

    1989-05-01

    High voltage insulation problems in electrostatic accelerators are discussed. The aim of the analysis is to broaden the knowledge, highlight the characteristics of insulation technology and design strategies to improve use. The basic geometry of the insulation in accelerators is considered. A detailed description of each of the insulation regions is provided. The gas gap insulation of the terminal voltage is found to be sensitive to regions of high electric stress. In order to obtain satisfactory performance from solid support insulation, the attention is focused on the electric stress value and distribution. Potential subjects for discussion and further investigations are given

  20. Electrostatically Driven Nanoballoon Actuator.

    Science.gov (United States)

    Barzegar, Hamid Reza; Yan, Aiming; Coh, Sinisa; Gracia-Espino, Eduardo; Dunn, Gabriel; Wågberg, Thomas; Louie, Steven G; Cohen, Marvin L; Zettl, Alex

    2016-11-09

    We demonstrate an inflatable nanoballoon actuator based on geometrical transitions between the inflated (cylindrical) and collapsed (flattened) forms of a carbon nanotube. In situ transmission electron microscopy experiments employing a nanoelectromechanical manipulator show that a collapsed carbon nanotube can be reinflated by electrically charging the nanotube, thus realizing an electrostatically driven nanoballoon actuator. We find that the tube actuator can be reliably cycled with only modest control voltages (few volts) with no apparent wear or fatigue. A complementary theoretical analysis identifies critical parameters for nanotube nanoballoon actuation.

  1. Electrostatics in Chemistry

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 4; Issue 7. Electrostatics in Chemistry - Molecular Electrostatic Potential: Visualization and Topography. Shridhar R Gadre Pravin K Bhadane. Series Article Volume 4 Issue 7 July 1999 pp 14-23 ...

  2. Sensitivity analysis of the electrostatic force distance curve using Sobol’s method and design of experiments

    International Nuclear Information System (INIS)

    Alhossen, I; Bugarin, F; Segonds, S; Villeneuve-Faure, C; Baudoin, F

    2017-01-01

    Previous studies have demonstrated that the electrostatic force distance curve (EFDC) is a relevant way of probing injected charge in 3D. However, the EFDC needs a thorough investigation to be accurately analyzed and to provide information about charge localization. Interpreting the EFDC in terms of charge distribution is not straightforward from an experimental point of view. In this paper, a sensitivity analysis of the EFDC is studied using buried electrodes as a first approximation. In particular, the influence of input factors such as the electrode width, depth and applied potential are investigated. To reach this goal, the EFDC is fitted to a law described by four parameters, called logistic law, and the influence of the electrode parameters on the law parameters has been investigated. Then, two methods are applied—Sobol’s method and the factorial design of experiment—to quantify the effect of each factor on each parameter of the logistic law. Complementary results are obtained from both methods, demonstrating that the EFDC is not the result of the superposition of the contribution of each electrode parameter, but that it exhibits a strong contribution from electrode parameter interaction. Furthermore, thanks to these results, a matricial model has been developed to predict EFDCs for any combination of electrode characteristics. A good correlation is observed with the experiments, and this is promising for charge investigation using an EFDC. (paper)

  3. Sensitivity analysis of the electrostatic force distance curve using Sobol’s method and design of experiments

    Science.gov (United States)

    Alhossen, I.; Villeneuve-Faure, C.; Baudoin, F.; Bugarin, F.; Segonds, S.

    2017-01-01

    Previous studies have demonstrated that the electrostatic force distance curve (EFDC) is a relevant way of probing injected charge in 3D. However, the EFDC needs a thorough investigation to be accurately analyzed and to provide information about charge localization. Interpreting the EFDC in terms of charge distribution is not straightforward from an experimental point of view. In this paper, a sensitivity analysis of the EFDC is studied using buried electrodes as a first approximation. In particular, the influence of input factors such as the electrode width, depth and applied potential are investigated. To reach this goal, the EFDC is fitted to a law described by four parameters, called logistic law, and the influence of the electrode parameters on the law parameters has been investigated. Then, two methods are applied—Sobol’s method and the factorial design of experiment—to quantify the effect of each factor on each parameter of the logistic law. Complementary results are obtained from both methods, demonstrating that the EFDC is not the result of the superposition of the contribution of each electrode parameter, but that it exhibits a strong contribution from electrode parameter interaction. Furthermore, thanks to these results, a matricial model has been developed to predict EFDCs for any combination of electrode characteristics. A good correlation is observed with the experiments, and this is promising for charge investigation using an EFDC.

  4. Large electrostatic accelerators

    International Nuclear Information System (INIS)

    Jones, C.M.

    1984-01-01

    The paper is divided into four parts: a discussion of the motivation for the construction of large electrostatic accelerators, a description and discussion of several large electrostatic accelerators which have been recently completed or are under construction, a description of several recent innovations which may be expected to improve the performance of large electrostatic accelerators in the future, and a description of an innovative new large electrostatic accelerator whose construction is scheduled to begin next year

  5. Determination of some heavy metals in wetlands by PIXE

    International Nuclear Information System (INIS)

    Ramirez O, J.; Rios M, C.

    2008-01-01

    In this work the results of the analysis are presented, using the PIXE technique (Proton Induced X-ray Emission), in soil samples of the El Bordo, Vetagrande, Zacatecas, before and after subjecting them to a lixiviation process for the recovering of gold, silver and mercury. This community is part of the mining region nearer to the Zacatecas city municipality, region in which the mining exploitation dates from the colonial time. During almost 350 years the 'yard benefit' method was used or amalgamation with mercury, process that besides having used big quantities of mercury, generated a great quantity of mineral waste calls 'mine wetlands', those that were accumulating, crawled by the rains, toward the streams that end in the prey 'The Pedernalillo'. The dispersion of wetlands them it has extended from the prey until the communities of Tacoaleche, Zoquite, Lampotal and El Bordo, embracing an approximate area of 16 x 2 Km 2 and forming with the course of the time an accumulated of several millions of tons. In order to determining if the process of recovery of gold, silver and mercury make soluble to other contained metals in these wastes, samples were gathered in an area of 600 m 2 in the community of The Border, Vetagrande, Zacatecas. Half of the samples were subjected to the lixiviation process in a local metal recovery plant and the other part was analyzed without processing. The analysis of both types of samples by means of the PIXE was carried out in the University of Arizona in Tucson. (Author)

  6. Electrostatics in Chemistry

    Indian Academy of Sciences (India)

    Electrostatics in Chemistry. 3. Molecular Electrostatic Potential: Visualization and Topography. Shridhar R Gadre and Pravin K Bhadane. 1 1. Basic Principles, Resona- nce, Vol.4, No.2, 11-19, 1999. 2. Electrostatic Potentials of. Atoms, Ions and Molecules,. Resonance, Vol.4, No.5, 40-51,. 1999. Topographical features of the ...

  7. Bicoherence Analysis of Electrostatic Interchange Mode Coupling in a Turbulent Laboratory Magnetosphere

    Science.gov (United States)

    Abler, M. C.; Mauel, M. E.; Saperstein, A.

    2017-12-01

    Plasmas confined by a strong dipole field exhibit interchange and entropy mode turbulence, which previous experiments have shown respond locally to active feedback [1]. On the Collisionless Terrella Experiment (CTX), this turbulence is characterized by low frequency, low order, quasi-coherent modes with complex spectral dynamics. We apply bicoherence analysis [2] to study nonlinear phase coupling in a variety of scenarios. First, we study the self-interaction of the naturally occurring interchange turbulence; this analysis is then expanded to include the effects of single or multiple driven modes in the frequency range of the background turbulent oscillations. Initial measurements of coupling coefficients are presented in both cases. Driven low frequency interchange modes are observed to generate multiple harmonics which persist throughout the plasma, becoming weaker as they propagate away from the actuator in the direction of the electron magnetic drift. Future work is also discussed, including application of wavelet bicoherence analysis and applications to planetary magnetospheres. [1] Roberts, Mauel, and Worstell, Phys Plasmas (2015). [2] Grierson, Worstell, and Mauel, Phys Plasmas (2009). Supported by NSF-DOE Partnership for Plasma Science Grants DOE-DE-FG02-00ER54585 and NSF-PHY-1201896.

  8. The new dedicated PIXE set-up at the National Environmental Research Institute, Denmark

    International Nuclear Information System (INIS)

    Kemp, Ka ring re; Waahlin, Peter

    1999-01-01

    The Niels Bohr Institute in Copenhagen was in the beginning of the 70'es one of the early places for PIXE. Contributions were made to the theoretical interpretation of the PIXE spectra as well as the practical application. The home-made 4 MV van de Graaff accelerator at the Niels Bohr Institute was an excellent tool for PIXE. The accelerator, which was used for many years, has now found its place on a museum after more than 40 years of active service. A dedicated PIXE set-up has now been established at the National Environmental Research Institute using a new 1.7 MV Tandem Pelletron (5SDH) from NEC. The main application is elemental analysis of outdoor aerosols. The main work is unsophisticated macro analyses, which do not push the equipment to its limits. This enables automated analysis of about 10,000 samples per year using very limited manpower resources. The research focuses on the contribution from various source types to the atmosphere over Europe, the North Atlantic and Greenland. Source compositions and their temporal variations are studied

  9. Improvement in the determination of elemental concentrations in PIXE analyses using artificial neural system

    International Nuclear Information System (INIS)

    Correa, R.; Dinator, M.I.; Morales, J.R.; Miranda, P.A.; Cancino, S.A.; Vila, I.; Requena, I.

    2008-01-01

    An Artificial Neural System, ANS, has been designed to operate in the analysis of spectra obtained from a PIXE (Proton Induced X-ray Emissions) application. The special designed ANS was used in the calculation of the concentrations of the major elements in the samples. Neural systems using several feed-forward ANN of similar topology working in parallel were trained with error back propagation algorithm using sets of spectra of known elemental concentrations. Following the training phase of the neural networks, other PIXE spectra were analyzed with this methodology providing unknown elemental concentrations. ANS results were compared with results obtained by traditional computer codes like AXIL and GUPIX, obtaining correlations factors close to one. The rather short time required to process each spectrum, of the order of microseconds, allows fast analysis of a large number of samples. Here we present applications of ANS in the PIXE analyses of samples of organic nature like liver, gills and muscle from fishes. ANS results were compared with elemental concentrations obtained in a previous application where a single ANN was used for each analyzed element. PIXE analyses were performed at the Nuclear Physics Laboratory of the University of Chile, using 2.2 MeV proton beams provided by a Van de Graaff accelerator. (author)

  10. Application of micro-PIXE, MRI and light microscopy for research in wood science and dendroecology

    International Nuclear Information System (INIS)

    Merela, M.; Pelicon, P.; Vavpetic, P.; Regvar, M.; Vogel-Mikus, K.; Sersa, I.; Policnik, H.; Pokorny, B.; Levanic, T.; Oven, P.

    2009-01-01

    Beech (Fagus sylvatica L.) branches were topped and after five months the wound response was analyzed by PIXE, 3D-MRI and light microscopy. From freshly cut and deeply frozen sample 30 μm thick longitudinal-radial tissue sections were prepared for anatomical investigations and micro-PIXE analysis. Light microscopy revealed the structural response to wounding, i.e. occurrence of the reaction zone between the exposed and dehydrated dead tissue and healthy sound wood. The reaction zone was characterized by tylosis in vessels and accumulation of colored deposits in parenchyma cells, fibres and vessels. 3D MRI of a parallel sample showed that the moisture content in the reaction zone was three times higher than in normal healthy wood. Micro-PIXE mapping at margins of compromised wood in beech revealed an increased concentration of potassium in the reaction zone. The increase in the calcium concentration was associated with the dehydrated tissue adjacent to reaction zones. In addition, micro-PIXE was used to determine the elemental distribution in annual tree rings. This may be relevant for retrospective assessment of environmental pollution in wood by measuring yearly increments as a biomonitoring tool. The analysis of European larch (Larix decidua Mill.) wood revealed a high similarity between optical characteristics (i.e. late versus earlywood) and elemental (e.g. Cl, K, Ca, Mn, Zn) distribution.

  11. Deep PIXE: finding diamonds with the proton microprobe

    International Nuclear Information System (INIS)

    Griffin, W.L.; Ryan, C.G.

    1991-01-01

    Since 1987 the CSIRO Div. of Exploration Geoscience has carried out a program of proton-microprobe (PIXE) analysis aimed at using trace-element data on indicator minerals to discriminate between those from diamondiferous and barren source rocks. The results have provided both important new tools for the exploration industry, and significant new information on the conditions and processes of diamond growth. Cr-pyrope garnet has been used as Ni thermometer while chromites, in partcular their Zn content, has allowed correlation of chromite composition with temperature. The two techniques described provide a significant increase in exploration efficiency, through early recognition and rejection of barren targets and concentration of resources on more promising targets. They also provide direct cost savings in evaluation of ore bodies once they are found. It is estimated that evaluation of a prospect by conventional bulk testing is expensive ($100-500K) and time-consuming; an evaluation by PIXE methods is done quickly for a tiny fraction of that cost. 1 refs., 4 figs

  12. Elemental composition of skin tissue by PIXE and INAA analyses

    International Nuclear Information System (INIS)

    Hollands, R.; Spyrou, N.M.

    1997-01-01

    Hypertrophic scars are a particular type of scar that can form after any type of dermal injury. They are unsightly, red, elevated above normal skin level, itchy and painful. At present no-one knows why these scars form. Due to the differences between scar tissue and normal skin it was decided to analyse skin tissue which at a later date would be compared to scar tissue. Spit skin graft (epidermis) samples as well as full thickness skin (epidermis to dermis) tissue were analysed using PIXE and RBS with a 2 MeV proton beam. The epidermis was compared to the dermis to see if there were any variations between the two. In all the samples P, S, Cl, K, Ca, Fe, and Cd were detected and in a majority of the samples Zn and Ba were found, using PIXE. It was found that, between the epidermis and dermis, there was an significant increase in P in the epidermis in both full thickness and split skin graft samples. Complementary elemental analysis was also performed using neutron activation, and Br, Na and Zn were detected. (author)

  13. PIXE measurements of Renaissance silverpoint drawings at VERA

    Energy Technology Data Exchange (ETDEWEB)

    Milota, Petra [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Reiche, Ina; Duval, Alain [Centre de recherche et de restauration des musees de France (C2RMF), CNRS UMR 171, Palais du Louvre, F-75001 Paris (France); Forstner, Oliver [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Guicharnaud, Helene [Centre de recherche et de restauration des musees de France (C2RMF), CNRS UMR 171, Palais du Louvre, F-75001 Paris (France); Kutschera, Walter [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Merchel, Silke [Centre Europeen de Recherche et d' Enseignement des Geosciences de l' Environnement (CEREGE), CNRS UMR 6635, F-13545 Aix en Provence (France); Priller, Alfred [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Schreiner, Manfred [Institute of Science and Technology in Art, Academy of Fine Arts Vienna, A-1010 Vienna (Austria); Steier, Peter [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Thobois, Elisabeth [Albertina, Albertinaplatz 1, A-1010 Vienna (Austria); Wallner, Anton; Wuenschek, Barbara [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Golser, Robin [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria)], E-mail: robin.golser@univie.ac.at

    2008-05-15

    Silverpoint drawings from the Renaissance are among the most precious and rarest treasures of graphical art. Our research group is particularly interested in the analysis of silverpoint drawings by Albrecht Duerer (1471-1528). A very sensitive and non-destructive analytical method, either spatially resolved synchrotron-radiation induced X-ray fluorescence (SY-XRF) or proton-induced X-ray emission (PIXE), is needed to determine the chemical composition of the very faint silver marks on such drawings. Duerer drawings from the collection of the Albertina, Vienna, were analyzed to amend existing data on Duerer drawings. For this purpose an external-beam PIXE setup was installed at the Vienna Environmental Research Accelerator (VERA). It allows to analyze a spot of {approx}0.15 mm on the object in air with 3 MeV protons, and to detect the emitted X-rays that are characteristic for the chemical composition with very good sensitivity and without harming the precious objects. After successful measurements on artificial test samples, four original silverpoint drawings were investigated: two portraits from Albrecht Duerer's very early period (self-portrait and portrait of his father) and two drawings from Duerer's sketch book of his travel to the Netherlands 1520/21.

  14. Electro-quasistatic analysis of an electrostatic induction micromotor using the cell method.

    Science.gov (United States)

    Monzón-Verona, José Miguel; Santana-Martín, Francisco Jorge; García-Alonso, Santiago; Montiel-Nelson, Juan Antonio

    2010-01-01

    An electro-quasistatic analysis of an induction micromotor has been realized by using the Cell Method. We employed the direct Finite Formulation (FF) of the electromagnetic laws, hence, avoiding a further discretization. The Cell Method (CM) is used for solving the field equations at the entire domain (2D space) of the micromotor. We have reformulated the field laws in a direct FF and analyzed physical quantities to make explicit the relationship between magnitudes and laws. We applied a primal-dual barycentric discretization of the 2D space. The electric potential has been calculated on each node of the primal mesh using CM. For verification purpose, an analytical electric potential equation is introduced as reference. In frequency domain, results demonstrate the error in calculating potential quantity is neglected (<3‰). In time domain, the potential value in transient state tends to the steady state value.

  15. Electro‐Quasistatic Analysis of an Electrostatic Induction Micromotor Using the Cell Method

    Directory of Open Access Journals (Sweden)

    José Miguel Monzón-Verona

    2010-10-01

    Full Text Available An electro-quasistatic analysis of an induction micromotor has been realized by using the Cell Method. We employed the direct Finite Formulation (FF of the electromagnetic laws, hence, avoiding a further discretization. The Cell Method (CM is used for solving the field equations at the entire domain (2D space of the micromotor. We have reformulated the field laws in a direct FF and analyzed physical quantities to make explicit the relationship between magnitudes and laws. We applied a primal-dual barycentric discretization of the 2D space. The electric potential has been calculated on each node of the primal mesh using CM. For verification purpose, an analytical electric potential equation is introduced as reference. In frequency domain, results demonstrate the error in calculating potential quantity is neglected (

  16. Compact electrostatic comb actuator

    Science.gov (United States)

    Rodgers, M. Steven; Burg, Michael S.; Jensen, Brian D.; Miller, Samuel L.; Barnes, Stephen M.

    2000-01-01

    A compact electrostatic comb actuator is disclosed for microelectromechanical (MEM) applications. The actuator is based upon a plurality of meshed electrostatic combs, some of which are stationary and others of which are moveable. One or more restoring springs are fabricated within an outline of the electrostatic combs (i.e. superposed with the moveable electrostatic combs) to considerably reduce the space required for the actuator. Additionally, a truss structure is provided to support the moveable electrostatic combs and prevent bending or distortion of these combs due to unbalanced electrostatic forces or external loading. The truss structure formed about the moveable electrostatic combs allows the spacing between the interdigitated fingers of the combs to be reduced to about one micron or less, thereby substantially increasing the number of active fingers which can be provided in a given area. Finally, electrostatic shields can be used in the actuator to substantially reduce unwanted electrostatic fields to further improve performance of the device. As a result, the compact electrostatic comb actuator of the present invention occupies only a fraction of the space required for conventional electrostatic comb actuators, while providing a substantial increase in the available drive force (up to one-hundred times).

  17. PIXE and the mysteries of Legionnaires' disease

    International Nuclear Information System (INIS)

    Chen, J.R.

    1981-01-01

    The authors describe the use of proton-induced X-ray emission (PIXE) to analyse the nickel concentrations of the autopsy specimens from victims of Legionnaires' disease. They show that the high nickel concentrations in the lung specimens from the first recognized Legionnaires' cases in Philadelphia in 1976 were due to contamination during the autopsies. Recently the authors have used PIXE to show that the selenium concentrations in the sera of the acutely ill Legionnaires' patients are significantly lower than in their matching convalescent-phase sera. This finding may be related to the patient's response to the disease or to the specific characteristics of the Legionella pneumophila itself. Studies show that the disease is not a rare illness but a worldwide one. General criteria concerning specimen collection are described

  18. The impact on materials science of ion beam analysis with electrostatic accelerators

    International Nuclear Information System (INIS)

    Amsel, G.; Battistig, G.

    2005-01-01

    The specific aspects of IBA for near surface and thin film analysis are discussed. In a number of cases IBA is the only analytical tool that may provide the information sought, in other cases it provides the most accessible or practical technique to be applied. While IBA is insensitive to the chemical state of the atoms analysed, it is unique in particular for determining with high accuracy and sensitivity absolute atomic quantities or concentrations, for studying with channeling techniques the atomic structure of crystalline thin films or materials near the surface, for isotopic tracing experiments with stable isotopes using nuclear reactions or resonances. Its advantages and drawbacks with respect to SIMS will be especially outlined. Due to these unique characteristics IBA has a long history of application, in combination with other characterisation methods, to a number of problems encountered in materials science, solid state and surface physics, solid state electrochemistry, thin film deposition or growth studies, trace and contamination determinations, etc. Representative applications will be presented that could not be obtained without IBA

  19. Programs for visualization, handling and quantification of PIXE maps at the AGLAE facility

    International Nuclear Information System (INIS)

    Pichon, L.; Calligaro, T.; Lemasson, Q.; Moignard, B.; Pacheco, C.

    2015-01-01

    The external beam setup of the AGLAE facility has been developed in order to combine PIXE with PIGE, EBS and recently IBIL for the analysis of cultural heritage artefacts. The upgraded external beam end-station integrates five large solid angle X-ray detectors either to reduce the risk of damage on sensitive artworks by decreasing the beam intensity or to routinely acquire elemental maps at various scales. While many programs are available to process PIXE maps acquired with nuclear microprobes, a software to process the major and trace elements PIXE maps point by point using GUPIX is not available. The present paper describes three programs developed for the AGLAE facility to process numerous maps obtained with multiple detectors. AGLAEMAP allows to handle maps and pixel groups within maps, TRAUPIXE to process quantitatively PIXE spectra of all pixels and DATAIMAGING to display the resulting quantitative elemental maps. The benefits of this software suite are demonstrated by processing a dataset acquired on a pellet of geostandard reference material and on a terre mêlée pottery shard sample created by the famous ceramist Bernard Palissy (1510–1589), highlighting chemical elements present in this polychrome ceramic.

  20. Programs for visualization, handling and quantification of PIXE maps at the AGLAE facility

    Energy Technology Data Exchange (ETDEWEB)

    Pichon, L., E-mail: laurent.pichon@culture.fr [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS, Ministère de la Culture et de la Communication, Chimie ParisTech, Palais du Louvre, 75001 Paris (France); Calligaro, T. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS, Ministère de la Culture et de la Communication, Chimie ParisTech, Palais du Louvre, 75001 Paris (France); PSL Research University, Chimie ParisTech-CNRS, Institut de Recherche Chimie Paris, UMR8247, 75005 Paris (France); Lemasson, Q.; Moignard, B.; Pacheco, C. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS, Ministère de la Culture et de la Communication, Chimie ParisTech, Palais du Louvre, 75001 Paris (France)

    2015-11-15

    The external beam setup of the AGLAE facility has been developed in order to combine PIXE with PIGE, EBS and recently IBIL for the analysis of cultural heritage artefacts. The upgraded external beam end-station integrates five large solid angle X-ray detectors either to reduce the risk of damage on sensitive artworks by decreasing the beam intensity or to routinely acquire elemental maps at various scales. While many programs are available to process PIXE maps acquired with nuclear microprobes, a software to process the major and trace elements PIXE maps point by point using GUPIX is not available. The present paper describes three programs developed for the AGLAE facility to process numerous maps obtained with multiple detectors. AGLAEMAP allows to handle maps and pixel groups within maps, TRAUPIXE to process quantitatively PIXE spectra of all pixels and DATAIMAGING to display the resulting quantitative elemental maps. The benefits of this software suite are demonstrated by processing a dataset acquired on a pellet of geostandard reference material and on a terre mêlée pottery shard sample created by the famous ceramist Bernard Palissy (1510–1589), highlighting chemical elements present in this polychrome ceramic.