  1. Contrast-enhanced breast MRI: factors affecting sensitivity and specificity

    Energy Technology Data Exchange (ETDEWEB)

    Piccoli, C.W. [Department of Radiology, Jefferson Medical College, Thomas Jefferson University Hospital, 132 South 10th Street, 7th floor, Philadelphia, PA 19107-5244 (United States)

    1997-12-31

    Contrast-enhanced MRI (CE-MRI) of the breast has been investigated for over 10 years. The reports of sensitivity for cancer detection have generally been greater than 90 %. However, estimates of specificity have varied greatly. Differing results are due to differences in study populations, technical methods and criteria for interpretation. Early and marked signal rise, detected using dynamic imaging technique following contrast administration, is the MRI hallmark of cancer. However, some malignant lesions may enhance slowly or minimally, and a variety of benign lesions may enhance rapidly with marked signal intensity. High resolution techniques generally requiring longer acquisition times are more likely to depict the slowly enhancing malignancies at the cost of a decrease in specificity due to lack of temporal resolution. This disadvantage may be offset by the improved visualization of lesion morphology with high resolution images. This report reviews the methods and results of the leading investigators of breast MRI. (orig.) With 3 figs., 70 refs.

  2. Contrast-enhanced breast MRI: factors affecting sensitivity and specificity

    International Nuclear Information System (INIS)

    Piccoli, C.W.

    1997-01-01

    Contrast-enhanced MRI (CE-MRI) of the breast has been investigated for over 10 years. The reports of sensitivity for cancer detection have generally been greater than 90 %. However, estimates of specificity have varied greatly. Differing results are due to differences in study populations, technical methods and criteria for interpretation. Early and marked signal rise, detected using dynamic imaging technique following contrast administration, is the MRI hallmark of cancer. However, some malignant lesions may enhance slowly or minimally, and a variety of benign lesions may enhance rapidly with marked signal intensity. High resolution techniques generally requiring longer acquisition times are more likely to depict the slowly enhancing malignancies at the cost of a decrease in specificity due to lack of temporal resolution. This disadvantage may be offset by the improved visualization of lesion morphology with high resolution images. This report reviews the methods and results of the leading investigators of breast MRI. (orig.)

  3. Low-field MRI can be more sensitive than high-field MRI

    Science.gov (United States)

    Coffey, Aaron M.; Truong, Milton L.; Chekmenev, Eduard Y.

    2013-12-01

    MRI signal-to-noise ratio (SNR) is the key factor for image quality. Conventionally, SNR is proportional to nuclear spin polarization, which scales linearly with magnetic field strength. Yet ever-stronger magnets present numerous technical and financial limitations. Low-field MRI can mitigate these constraints with equivalent SNR from non-equilibrium ‘hyperpolarization' schemes, which increase polarization by orders of magnitude independently of the magnetic field. Here, theory and experimental validation demonstrate that combination of field independent polarization (e.g. hyperpolarization) with frequency optimized MRI detection coils (i.e. multi-turn coils using the maximum allowed conductor length) results in low-field MRI sensitivity approaching and even rivaling that of high-field MRI. Four read-out frequencies were tested using samples with identical numbers of 1H and 13C spins. Experimental SNRs at 0.0475 T were ∼40% of those obtained at 4.7 T. Conservatively, theoretical SNRs at 0.0475 T 1.13-fold higher than those at 4.7 T were possible despite an ∼100-fold lower detection frequency, indicating feasibility of high-sensitivity MRI without technically challenging, expensive high-field magnets. The data at 4.7 T and 0.0475 T was obtained from different spectrometers with different RF probes. The SNR comparison between the two field strengths accounted for many differences in parameters such as system noise figures and variations in the probe detection coils including Q factors and coil diameters.

  4. Sensitivity of MRI in detecting alveolar infiltrates. Experimental studies

    International Nuclear Information System (INIS)

    Biederer, J.; Busse, I.; Grimm, J.; Reuter, M.; Heller, M.; Muhle, C.; Freitag, S.

    2002-01-01

    Purpose: An experimental study using porcine lung explants and a dedicated chest phantom to evaluate the signal intensity of artificial alveolar infiltrates with T 1 - and T 2 -weighted MRI sequences. Material and Methods: 10 porcine lung explants were intubated, transferred into the cavity of a MRI-compatible chest phantom and inflated by continuous evacuation of the artificial pleural space. All lungs were examined with MRI at 1.5 T before and after intra-tracheal instillation of either 100 or 200 ml gelatine-stabilised liquid to simulate alveolar infiltrates. MR-examination comprised gradient echo (2D- and 3D-GRE) and fast spin echo sequences (T 2 -TSE and T 2 -HASTE). The signal intensity of lung parenchyma was evaluated at representative cross sections using a standardised scheme. Control studies were acquired with helical CT. Results: The instilled liquid caused patchy confluent alveolar infiltrates resembling the findings in patients with pneumonia or ARDS. CT revealed typical ground-glass opacities. Before the application of the liquid, only T 2 -HASTE and T 2 -TSE displayed lung parenchyma signals with a signal/noise ratio of 3.62 and 1.39, respectively. After application of the liquid, both T 2 -weighted sequences showed clearly visible infiltrates with an increase in signal intensity of approx. 30% at 100 ml (p 2 -weighted sequences detects artificial alveolar infiltrates with high signal intensity and may be a highly sensitive tool to detect pneumonia in patients. (orig.) [de

  5. MRI

    DEFF Research Database (Denmark)

    Schroeter, Aileen; Rudin, Markus; Gianolio, Eliana

    2017-01-01

    This chapter discusses principles of nuclear magnetic resonance (NMR) and MRI followed by a survey on the major classes of MRI contrast agents (CA), their modes of action, and some of the most significative applications. The two more established classes of MRI-CA are represented by paramagnetic...... been attained that markedly increase the number and typology of systems with CEST properties. Currently much attention is also devoted to hyperpolarized molecules that display a sensitivity enhancement sufficient for their direct exploitation for the formation of the MR image. A real breakthrough...

  6. Pico-CSIA: Picomolar Scale Compound-Specific Isotope Analyses

    Science.gov (United States)

    Baczynski, A. A.; Polissar, P. J.; Juchelka, D.; Schwieters, J. B.; Hilkert, A.; Freeman, K. H.

    2016-12-01

    The basic approach to analyzing molecular isotopes has remained largely unchanged since the late 1990s. Conventional compound-specific isotope analyses (CSIA) are conducted using capillary gas chromatography (GC), a combustion interface, and an isotope-ratio mass spectrometer (IRMS). Commercially available GC-IRMS systems are comprised of components with inner diameters ≥0.25 mm and employ helium flow rates of 1-4 mL/min. These flow rates are an order of magnitude larger than what the IRMS can accept. Consequently, ≥90% of the sample is lost through the open split, and 1-10s of nanomoles of carbon are required for analysis. These sample requirements are prohibitive for many biomarkers, which are often present in picomolar concentrations. We utilize the resolving power and low flows of narrow-bore capillary GC to improve the sensitivity of CSIA. Narrow bore capillary columns (<0.25 mm ID) allow low helium flow rates of ≤0.5mL/min for more efficient sample transfer to the ion source of the IRMS while maintaining the high linear flow rates necessary to preserve narrow peak widths ( 250 ms). The IRMS has been fitted with collector amplifiers configured to 25 ms response times for rapid data acquisition across narrow peaks. Previous authors (e.g., Sacks et al., 2007) successfully demonstrated improved sensitivity afforded by narrow-bore GC columns. They reported an accuracy and precision of 1.4‰ for peaks with an average width at half maximum of 720 ms for 100 picomoles of carbon on column. Our method builds on their advances and further reduces peak widths ( 600 ms) and the amount of sample lost prior to isotopic analysis. Preliminary experiments with 100 picomoles of carbon on column show an accuracy and standard deviation <1‰. With further improvement, we hope to demonstrate robust isotopic analysis of 10s of picomoles of carbon, more than 2 orders of magnitude lower than commercial systems. The pico-CSIA method affords high-precision isotopic analyses for

  7. A sensitive zinc-activated 129Xe MRI probe

    International Nuclear Information System (INIS)

    Kotera, N.; Delacour, L.; Traore, T.; Buisson, D.A.; Taran, F.; Coudert, S.; Rousseau, B.; Tassali, N.; Leonce, E.; Boutin, C.; Berthault, P.; Brotin, T.; Dutasta, J.P.

    2012-01-01

    Herein we propose the use of hyper-polarized 129 Xe nuclear magnetic resonance (NMR) spectroscopy for the sensitive detection of Zn 2+ ions. To achieve this goal, the noble gas is encapsulated in dedicated host systems bearing a ligand that chelates the Zn 2+ ions. Cryptophanes, aromatic cage molecules made of cyclotriveratrylene groups, are perfectly suited to this purpose as 1) they can easily be rendered water-soluble, 2) the noble gas has a high affinity for their cavity, 3) when xenon is encapsulated, it takes a specific NMR frequency, and 4) xenon exchange in and out of the cavity insures a continuous refreshment of the Xe-cryptophane environment in hyper-polarization. We constructed a powerful 129 Xe NMR-based sensor of Zn 2+ ions, which enables for the first time measurement of Zn 2+ concentrations as low as 100 nm. This high sensitivity was achieved thanks to a smart 129 Xe MRI sensor, where the binding of the ion to the target is accompanied by a change in NMR parameters. We have also demonstrated the importance of working with enantiopure cryptophane derivatives. (O.M.)

  8. A Sensitivity Analysis of fMRI Balloon Model

    KAUST Repository

    Zayane, Chadia

    2015-04-22

    Functional magnetic resonance imaging (fMRI) allows the mapping of the brain activation through measurements of the Blood Oxygenation Level Dependent (BOLD) contrast. The characterization of the pathway from the input stimulus to the output BOLD signal requires the selection of an adequate hemodynamic model and the satisfaction of some specific conditions while conducting the experiment and calibrating the model. This paper, focuses on the identifiability of the Balloon hemodynamic model. By identifiability, we mean the ability to estimate accurately the model parameters given the input and the output measurement. Previous studies of the Balloon model have somehow added knowledge either by choosing prior distributions for the parameters, freezing some of them, or looking for the solution as a projection on a natural basis of some vector space. In these studies, the identification was generally assessed using event-related paradigms. This paper justifies the reasons behind the need of adding knowledge, choosing certain paradigms, and completing the few existing identifiability studies through a global sensitivity analysis of the Balloon model in the case of blocked design experiment.

  9. A Sensitivity Analysis of fMRI Balloon Model

    KAUST Repository

    Zayane, Chadia; Laleg-Kirati, Taous-Meriem

    2015-01-01

    Functional magnetic resonance imaging (fMRI) allows the mapping of the brain activation through measurements of the Blood Oxygenation Level Dependent (BOLD) contrast. The characterization of the pathway from the input stimulus to the output BOLD signal requires the selection of an adequate hemodynamic model and the satisfaction of some specific conditions while conducting the experiment and calibrating the model. This paper, focuses on the identifiability of the Balloon hemodynamic model. By identifiability, we mean the ability to estimate accurately the model parameters given the input and the output measurement. Previous studies of the Balloon model have somehow added knowledge either by choosing prior distributions for the parameters, freezing some of them, or looking for the solution as a projection on a natural basis of some vector space. In these studies, the identification was generally assessed using event-related paradigms. This paper justifies the reasons behind the need of adding knowledge, choosing certain paradigms, and completing the few existing identifiability studies through a global sensitivity analysis of the Balloon model in the case of blocked design experiment.

  10. Picomolar dichotomous activity of gnidimacrin against HIV-1.

    Directory of Open Access Journals (Sweden)

    Li Huang

    Full Text Available Highly active antiretroviral therapy (HAART has offered a promising approach for controlling HIV-1 replication in infected individuals. However, with HARRT, HIV-1 is suppressed rather than eradicated due to persistence of HIV-1 in latent viral reservoirs. Thus, purging the virus from latent reservoirs is an important strategy toward eradicating HIV-1 infection. In this study, we discovered that the daphnane diterpene gnidimacrin, which was previously reported to have potent anti-cancer cell activity, activated HIV-1 replication and killed persistently-infected cells at picomolar concentrations. In addition to its potential to purge HIV-1 from latently infected cells, gnidimacrin potently inhibited a panel of HIV-1 R5 virus infection of peripheral blood mononuclear cells (PBMCs at an average concentration lower than 10 pM. In contrast, gnidimacrin only partially inhibited HIV-1 ×4 virus infection of PBMCs. The strong anti-HIV-1 R5 virus activity of gnidimacrin was correlated with its effect on down-regulation of the HIV-1 coreceptor CCR5. The anti-R5 virus activity of gnidimacrin was completely abrogated by a selective protein kinase C beta inhibitor enzastaurin, which suggests that protein kinase C beta plays a key role in the potent anti-HIV-1 activity of gnidimacrin in PBMCs. In summary, these results suggest that gnidimacrin could activate latent HIV-1, specifically kill HIV-1 persistently infected cells, and inhibit R5 viruses at picomolar concentrations.

  11. Sensitivity of enhanced MRI for the detection of breast cancer: new, multicentric, residual, and recurrent

    International Nuclear Information System (INIS)

    Davis, P.L.; McCarty, K.S. Jr.

    1997-01-01

    Magnetic resonance imaging (MRI) of the breast brings the advantages of high resolution cross-sectional imaging to breast cancer diagnosis, treatment and research: improved cancer detection, staging, selection of therapy, evaluation of therapeutic response in vivo, detection of recurrence, and even the development of new therapies. Until now breast cancer treatment and research has been impeded by the limited means of evaluating the breast cancer in vivo: primarily clinical palpation and mammography of the breast tumor. A review of the initial studies shows that with the use of paramagnetic contrast agents, MRI has a sensitivity of 96 % for detecting breast cancers. MRI detects multicentric disease with a sensitivity of 98 %, superior to any other modality. The ability of MRI to detect recurrent local breast cancer in the conservatively treated breast is nearly 100 %. MRI is capable of monitoring tumor response to chemotherapy and actually guiding therapeutic interventions such as interstitial laser photocoagulation. (orig.)

  12. Femoroacetabular cam-type impingement: Diagnostic sensitivity and specificity of radiographic views compared to radial MRI

    International Nuclear Information System (INIS)

    Domayer, S.E.; Ziebarth, K.; Chan, J.; Bixby, S.; Mamisch, T.C.; Kim, Y.J.

    2011-01-01

    Purpose: To retrospectively assess the diagnostic sensitivity of 45° Dunn view and cross-table lateral radiographs for the assessment of cam deformity by comparison with radial MRI. Materials and methods: 60 cases with radiographs (38 a–p and 45° Dunn views, 22 a–p and cross-table lateral views) and radial MRI were assessed. Alpha angle measurements were obtained both for radiographs and radial MRI. Statistics included frequency analysis, bivariate linear correlation analyses of MRI and radiograph measurements and cross-table analyses testing for the sensitivity and specificity of radiographs for the detection of an alpha angle larger than 55°. Results: 53.3% had the maximum alpha angle in the superior–anterior aspect of the femoral head–neck junction. Cam deformity was found in 45/60 cases (75%) in radial MRI. Pearson correlation demonstrated the Dunn view was most accurate for the superior–anterior aspect (.772, P < .001). The cross-table lateral views were best suited for the anterior–superior aspect (.511, P < .05). The sensitivity for cam deformity in the Dunn view was 96.4% vs. 70.6% in the cross-table lateral view. Conclusion: The 45° Dunn view can improve the first line of impingement diagnostics. Radial MRI however remains indispensable for pre-operative planning and the evaluation of symptomatic cases without obvious deformity.

  13. Oxygen-sensitive 3He-MRI in bronchiolitis obliterans after lung transplantation

    International Nuclear Information System (INIS)

    Gast, Klaus K.; Biedermann, Alexander; Herweling, Annette; Schreiber, Wolfgang G.; Schmiedeskamp, Joerg; Mayer, Eckhard; Heussel, Claus P.; Markstaller, Klaus; Eberle, Balthasar; Kauczor, Hans-Ulrich

    2008-01-01

    Oxygen-sensitive 3 He-MRI was studied for the detection of differences in intrapulmonary oxygen partial pressure (pO 2 ) between patients with normal lung transplants and those with bronchiolitis obliterans syndrome (BOS). Using software developed in-house, oxygen-sensitive 3 He-MRI datasets from patients with normal lung grafts (n = 8) and with BOS (n = 6) were evaluated quantitatively. Datasets were acquired on a 1.5-T system using a spoiled gradient echo pulse sequence. Underlying diseases were pulmonary emphysema (n 10 datasets) and fibrosis (n = 4). BOS status was verified by pulmonary function tests. Additionally, 3 He-MRI was assessed blindedly for ventilation defects. Median intrapulmonary pO 2 in patients with normal lung grafts was 146 mbar compared with 108 mbar in patients with BOS. Homogeneity of pO2 distribution was greater in normal grafts (standard deviation pO2 34 versus 43 mbar). Median oxygen decrease rate during breath hold was higher in unaffected patients (-1.75 mbar/s versus -0.38 mbar/s). Normal grafts showed fewer ventilation defects (5% versus 28%, medians). Oxygen-sensitive 3 He-MRI appears capable of demonstrating differences of intrapulmonary pO2 between normal lung grafts and grafts affected by BOS. Oxygen-sensitive 3 He-MRI may add helpful regional information to other diagnostic techniques for the assessment and follow-up of lung transplant recipients. (orig.)

  14. Sensitivity quantification of remote detection NMR and MRI

    Science.gov (United States)

    Granwehr, J.; Seeley, J. A.

    2006-04-01

    A sensitivity analysis is presented of the remote detection NMR technique, which facilitates the spatial separation of encoding and detection of spin magnetization. Three different cases are considered: remote detection of a transient signal that must be encoded point-by-point like a free induction decay, remote detection of an experiment where the transient dimension is reduced to one data point like phase encoding in an imaging experiment, and time-of-flight (TOF) flow visualization. For all cases, the sensitivity enhancement is proportional to the relative sensitivity between the remote detector and the circuit that is used for encoding. It is shown for the case of an encoded transient signal that the sensitivity does not scale unfavorably with the number of encoded points compared to direct detection. Remote enhancement scales as the square root of the ratio of corresponding relaxation times in the two detection environments. Thus, remote detection especially increases the sensitivity of imaging experiments of porous materials with large susceptibility gradients, which cause a rapid dephasing of transverse spin magnetization. Finally, TOF remote detection, in which the detection volume is smaller than the encoded fluid volume, allows partial images corresponding to different time intervals between encoding and detection to be recorded. These partial images, which contain information about the fluid displacement, can be recorded, in an ideal case, with the same sensitivity as the full image detected in a single step with a larger coil.

  15. Modic Type 1 Changes: Detection Performance of Fat-Suppressed Fluid-Sensitive MRI Sequences.

    Science.gov (United States)

    Finkenstaedt, Tim; Del Grande, Filippo; Bolog, Nicolae; Ulrich, Nils; Tok, Sina; Kolokythas, Orpheus; Steurer, Johann; Andreisek, Gustav; Winklhofer, Sebastian

    2018-02-01

     To assess the performance of fat-suppressed fluid-sensitive MRI sequences compared to T1-weighted (T1w) / T2w sequences for the detection of Modic 1 end-plate changes on lumbar spine MRI.  Sagittal T1w, T2w, and fat-suppressed fluid-sensitive MRI images of 100 consecutive patients (consequently 500 vertebral segments; 52 female, mean age 74 ± 7.4 years; 48 male, mean age 71 ± 6.3 years) were retrospectively evaluated. We recorded the presence (yes/no) and extension (i. e., Likert-scale of height, volume, and end-plate extension) of Modic I changes in T1w/T2w sequences and compared the results to fat-suppressed fluid-sensitive sequences (McNemar/Wilcoxon-signed-rank test).  Fat-suppressed fluid-sensitive sequences revealed significantly more Modic I changes compared to T1w/T2w sequences (156 vs. 93 segments, respectively; p definition of Modic I changes is not fully applicable anymore.. · Fat-suppressed fluid-sensitive MRI sequences revealed more/greater extent of Modic I changes.. · Finkenstaedt T, Del Grande F, Bolog N et al. Modic Type 1 Changes: Detection Performance of Fat-Suppressed Fluid-Sensitive MRI Sequences. Fortschr Röntgenstr 2018; 190: 152 - 160. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Diffusion properties of conventional and calcium-sensitive MRI contrast agents in the rat cerebral cortex.

    Science.gov (United States)

    Hagberg, Gisela E; Mamedov, Ilgar; Power, Anthony; Beyerlein, Michael; Merkle, Hellmut; Kiselev, Valerij G; Dhingra, Kirti; Kubìček, Vojtĕch; Angelovski, Goran; Logothetis, Nikos K

    2014-01-01

    Calcium-sensitive MRI contrast agents can only yield quantitative results if the agent concentration in the tissue is known. The agent concentration could be determined by diffusion modeling, if relevant parameters were available. We have established an MRI-based method capable of determining diffusion properties of conventional and calcium-sensitive agents. Simulations and experiments demonstrate that the method is applicable both for conventional contrast agents with a fixed relaxivity value and for calcium-sensitive contrast agents. The full pharmacokinetic time-course of gadolinium concentration estimates was observed by MRI before, during and after intracerebral administration of the agent, and the effective diffusion coefficient D* was determined by voxel-wise fitting of the solution to the diffusion equation. The method yielded whole brain coverage with a high spatial and temporal sampling. The use of two types of MRI sequences for sampling of the diffusion time courses was investigated: Look-Locker-based quantitative T(1) mapping, and T(1) -weighted MRI. The observation times of the proposed MRI method is long (up to 20 h) and consequently the diffusion distances covered are also long (2-4 mm). Despite this difference, the D* values in vivo were in agreement with previous findings using optical measurement techniques, based on observation times of a few minutes. The effective diffusion coefficient determined for the calcium-sensitive contrast agents may be used to determine local tissue concentrations and to design infusion protocols that maintain the agent concentration at a steady state, thereby enabling quantitative sensing of the local calcium concentration. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Bucket-handle meniscal tears of the knee: sensitivity and specificity of MRI signs

    International Nuclear Information System (INIS)

    Dorsay, Theodore A.; Helms, Clyde A.

    2003-01-01

    To determine the sensitivity and specificity of reported MRI signs in the evaluation of bucket-handle tears of the knee.Design and patients A retrospective analysis of 71 knee MR examinations that were read as displaying evidence of a bucket-handle or ''bucket-handle type'' tear was performed. We evaluated for the presence or absence of the absent bow tie sign, the coronal truncation sign, the double posterior cruciate ligament (PCL) sign, the anterior flipped fragment sign, and a fragment displaced into the intercondylar notch. Sensitivity and specificity were calculated relative to the gold standard of arthroscopy. Forty-three of 71 cases were surgically proven as bucket-handle tears. The absent bow tie sign demonstrated a sensitivity of 88.4%. The presence of at least one of the displaced fragment signs had a sensitivity of 90.7%. A finding of both the absent bow tie sign and one of the displaced fragment signs demonstrated a specificity of 85.7%. The double PCL sign demonstrated a specificity of 100%. The anterior flipped meniscus sign had a specificity of 89.7%. Bucket-handle tears of the menisci, reported in about 10% of most large series, have been described by several signs with MRI. This report gives the sensitivity and specificity of MRI for bucket-handle tears using each of these signs independently and in combination. MRI is shown to be very accurate for diagnosing bucket-handle tears when two or more of these signs coexist. (orig.)

  18. Sensitivity of different MRI sequences in the early detection of melanoma brain metastases

    Science.gov (United States)

    Breckwoldt, Michael O.; Schwarz, Daniel; Radbruch, Alexander; Enk, Alexander; Bendszus, Martin; Hassel, Jessica; Schlemmer, Heinz-Peter

    2018-01-01

    Background After the emergence of new MRI techniques such as susceptibility- and diffusion-weighted imaging (SWI and DWI) and because of specific imaging characteristics of melanoma brain metastases (MBM), it is unclear which MRI sequences are most beneficial for detection of MBM. This study was performed to investigate the sensitivity of six clinical MRI sequences in the early detection of MBM. Methods Medical records of all melanoma patients referred to our center between November 2005 and December 2016 were reviewed for presence of MBM. Analysis encompassed six MRI sequences at the time of initial diagnosis of first or new MBM, including non-enhanced T1-weighted (T1w), contrast-enhanced T1w (ceT1w), T2-weighted (T2w), T2w-FLAIR, susceptibility-weighted (SWI) and diffusion-weighted (DWI) MRI. Each lesion was rated with respect to its conspicuity (score from 0—not detectable to 3—clearly visible). Results Of 1210 patients, 217 with MBM were included in the analysis and up to 5 lesions per patient were evaluated. A total of 720 metastases were assessed and all six sequences were available for 425 MBM. Sensitivity (conspicuity ≥2) was 99.7% for ceT1w, 77.0% for FLAIR, 64.7% for SWI, 61.0% for T2w, 56.7% for T1w, and 48.4% for DWI. Thirty-one (7.3%) of 425 lesions were only detectable by ceT1w but no other sequence. Conclusions Contrast-enhanced T1-weighting is more sensitive than all other sequences for detection of MBM. Disruption of the blood-brain-barrier is consistently an earlier sign in MBM than perifocal edema, signal loss on SWI or diffusion restriction. PMID:29596475

  19. Modic type 1 changes. Detection performance of fat-suppressed fluid-sensitive MRI sequences

    Energy Technology Data Exchange (ETDEWEB)

    Finkenstaedt, Tim; Andreisek, Gustav [University Hospital Zurich (Switzerland). Inst. of Diagnostic and Interventional Radiology; Del Grande, Filippo [Ospedale Regionale di Lugano (Switzerland). Inst. of Diagnostic and Interventional Radiology; Bolog, Nicolae [Phoenix Diagnostic Clinic, Bucharest (Romania); Ulrich, Nils; Tok, Sina [Schulthess Clinic, Zurich (Switzerland). Dept. of Neurosurgery; Kolokythas, Orpheus [Kantonsspital Winterthur (Switzerland). Inst. for Radiology and Nuclear Medicine; Steurer, Johann [University Hospital Zurich (Switzerland). Horten Center for Patient Oriented Research and Knowledge Transfer; Winklhofer, Sebastian [University Hospital Zurich (Switzerland). Inst. of Diagnostic and Interventional Radiology; University Hospital Zurich (Switzerland). Dept. of Neuroradiology; Collaboration: LSOS Study Group

    2018-02-15

    To assess the performance of fat-suppressed fluid-sensitive MRI sequences compared to T1-weighted (T1w) / T2w sequences for the detection of Modic 1 end-plate changes on lumbar spine MRI. Sagittal T1w, T2w, and fat-suppressed fluid-sensitive MRI images of 100 consecutive patients (consequently 500 vertebral segments; 52 female, mean age 74 ± 7.4 years; 48 male, mean age 71 ± 6.3 years) were retrospectively evaluated. We recorded the presence (yes/no) and extension (i.e., Likert-scale of height, volume, and end-plate extension) of Modic I changes in T1w/T2w sequences and compared the results to fat-suppressed fluid-sensitive sequences (McNemar/Wilcoxon-signed-rank test). Fat-suppressed fluid-sensitive sequences revealed significantly more Modic I changes compared to T1w/T2w sequences (156 vs. 93 segments, respectively; p < 0.001). The extension of Modic I changes in fat-suppressed fluid-sensitive sequences was significantly larger compared to T1w/T2w sequences (height: 2.53 ± 0.82 vs. 2.27 ± 0.79, volume: 2.35 ± 0.76 vs. 2.1 ± 0.65, end-plate: 2.46 ± 0.76 vs. 2.19 ± 0.81), (p < 0.05). Modic I changes that were only visible in fat-suppressed fluid-sensitive sequences but not in T1w/T2w sequences were significantly smaller compared to Modic I changes that were also visible in T1w/T2w sequences (p < 0.05). In conclusion, fat-suppressed fluid-sensitive MRI sequences revealed significantly more Modic I end-plate changes and demonstrated a greater extent compared to standard T1w/T2w imaging.

  20. MRI

    Science.gov (United States)

    ... the room. Pins, hairpins, metal zippers, and similar metallic items can distort the images. Removable dental work ... an MRI can cause heart pacemakers and other implants not to work as well. The magnets can ...

  1. Correlation of oxygenation and perfusion sensitive MRI with invasive micro probe measurements in healthy mice brain.

    Science.gov (United States)

    Sedlacik, Jan; Reitz, Matthias; Bolar, Divya S; Adalsteinsson, Elfar; Schmidt, Nils O; Fiehler, Jens

    2015-03-01

    The non-invasive assessment of (patho-)physiological parameters such as, perfusion and oxygenation, is of great importance for the characterization of pathologies e.g., tumors, which may be helpful to better predict treatment response and potential outcome. To better understand the influence of physiological parameters on the investigated oxygenation and perfusion sensitive MRI methods, MRI measurements were correlated with subsequent invasive micro probe measurements during free breathing conditions of air, air+10% CO2 and 100% O2 in healthy mice brain. MRI parameters were the irreversible (R2), reversible (R2') and effective (R2*) transverse relaxation rates, venous blood oxygenation level assessed by quantitative blood oxygenation level dependent (qBOLD) method and cerebral blood flow (CBF) assessed by arterial spin labeling (ASL) using a 7 T small animal MRI scanner. One to two days after MRI, tissue perfusion and pO2 were measured by Laser-Doppler flowmetry and fluorescence quenching micro probes, respectively. The tissue pO2 values were converted to blood oxygen saturation by using the Hill equation. The animals were anesthetized by intra peritoneal injection of ketamine-xylazine-acepromazine (10-2-0.3 mg/ml · kg). Results for normal/hypercapnia/hyperoxia conditions were: R2[s(∧)-1] = 20.7/20.4/20.1, R2*[s(∧)-1] = 31.6/29.6/25.9, R2'[s-(∧)1] = 10.9/9.2/5.7, qBOLD venous blood oxygenation level = 0.43/0.51/0.56, CBF[ml · min(∧)-1 · 100 g(∧)-1] = 70.6/105.5/81.8, Laser-Doppler flowmetry[a.u.] = 89.2/120.2/90.6 and pO2[mmHg] = 6.3/32.3/46.7. All parameters were statistically significantly different with P effects of anesthesia and trauma due to micro probe insertion are strong confounding factors and need close attention for study planning and conduction of experiments. Investigation of the correlation of perfusion and oxygenation sensitive MRI methods with micro probe measurements in pathologic tissue such as tumors is now of compelling interest

  2. Residual fMRI sensitivity for identity changes in acquired prosopagnosia.

    Science.gov (United States)

    Fox, Christopher J; Iaria, Giuseppe; Duchaine, Bradley C; Barton, Jason J S

    2013-01-01

    While a network of cortical regions contribute to face processing, the lesions in acquired prosopagnosia are highly variable, and likely result in different combinations of spared and affected regions of this network. To assess the residual functional sensitivities of spared regions in prosopagnosia, we designed a rapid event-related functional magnetic resonance imaging (fMRI) experiment that included pairs of faces with same or different identities and same or different expressions. By measuring the release from adaptation to these facial changes we determined the residual sensitivity of face-selective regions-of-interest. We tested three patients with acquired prosopagnosia, and all three of these patients demonstrated residual sensitivity for facial identity changes in surviving fusiform and occipital face areas of either the right or left hemisphere, but not in the right posterior superior temporal sulcus. The patients also showed some residual capabilities for facial discrimination with normal performance on the Benton Facial Recognition Test, but impaired performance on more complex tasks of facial discrimination. We conclude that fMRI can demonstrate residual processing of facial identity in acquired prosopagnosia, that this adaptation can occur in the same structures that show similar processing in healthy subjects, and further, that this adaptation may be related to behavioral indices of face perception.

  3. Quantitation of MRI sensitivity to quasi-monodisperse microbubble contrast agents for spatially resolved manometry.

    Science.gov (United States)

    Bencsik, Martin; Al-Rwaili, Amgad; Morris, Robert; Fairhurst, David J; Mundell, Victoria; Cave, Gareth; McKendry, Jonathan; Evans, Stephen

    2013-11-01

    The direct in-vivo measurement of fluid pressure cannot be achieved with MRI unless it is done with the contribution of a contrast agent. No such contrast agents are currently available commercially, whilst those demonstrated previously only produced qualitative results due to their broad size distribution. Our aim is to quantitate then model the MR sensitivity to the presence of quasi-monodisperse microbubble populations. Lipid stabilised microbubble populations with mean radius 1.2 ± 0.8 μm have been produced by mechanical agitation. Contrast agents with increasing volume fraction of bubbles up to 4% were formed and the contribution the bubbles bring to the relaxation rate was quantitated. A periodic pressure change was also continuously applied to the same contrast agent, until MR signal changes were only due to bubble radius change and not due to a change in bubble density. The MR data compared favourably with the prediction of an improved numerical simulation. An excellent MR sensitivity of 23 % bar(-1) has been demonstrated. This work opens up the possibility of generating microbubble preparations tailored to specific applications with optimised MR sensitivity, in particular MRI based in-vivo manometry. Copyright © 2012 Wiley Periodicals, Inc.

  4. Residual fMRI sensitivity for identity changes in acquired prosopagnosia

    Directory of Open Access Journals (Sweden)

    Christopher J Fox

    2013-10-01

    Full Text Available While a network of cortical regions contribute to face processing, the lesions in acquired prosopagnosia are highly variable, and likely result in different combinations of spared and affected regions of this network. To assess the residual functional sensitivities of spared regions in prosopagnosia, we designed a rapid event-related functional magnetic resonance imaging (fMRI experiment that included pairs of faces with same or different identities and same or different expressions. By measuring the release from adaptation to these facial changes we determined the residual sensitivity of face-selective regions-of-interest. We tested three patients with acquired prosopagnosia, and all three of these patients demonstrated residual sensitivity for facial identity changes in surviving fusiform and occipital face areas of either the right or left hemisphere, but not in the right posterior superior temporal sulcus. The patients also showed some residual capabilities for facial discrimination with normal performance on the Benton Facial Recognition Test, but impaired performance on more complex tasks of facial discrimination. We conclude that fMRI can demonstrate residual processing of facial identity in acquired prosopagnosia, that this adaptation can occur in the same structures that show similar processing in healthy subjects, and further, that this adaptation may be related to behavioral indices of face perception.

  5. Correlation of oxygenation and perfusion sensitive MRI with invasive micro probe measurements in healthy mice brain

    International Nuclear Information System (INIS)

    Sedlacik, Jan; Fiehler, Jens; Reitz, Matthias; Schmidt, Nils O.; Bolar, Divya S.; Adalsteinsson, Elfar

    2015-01-01

    The non-invasive assessment of (patho-)physiological parameters such as, perfusion and oxygenation, is of great importance for the characterization of pathologies e.g., tumors, which may be helpful to better predict treatment response and potential outcome. To better understand the influence of physiological parameters on the investigated oxygenation and perfusion sensitive MRI methods, MRI measurements were correlated with subsequent invasive micro probe measurements during free breathing conditions of air, air+10% CO2 and 100% O2 in healthy mice brain. MRI parameters were the irreversible (R2), reversible (R2') and effective (R2*) transverse relaxation rates, venous blood oxygenation level assessed by quantitative blood oxygenation level dependent (qBOLD) method and cerebral blood flow (CBF) assessed by arterial spin labeling (ASL) using a 7T small animal MRI scanner. One to two days after MRI, tissue perfusion and pO2 were measured by Laser-Doppler flowmetry and fluorescence quenching micro probes, respectively. The tissue pO2 values were converted to blood oxygen saturation by using the Hill equation. The animals were anesthetized by intra peritoneal injection of ketamine-xylazine-acepromazine (10-2-0.3 mg/ml.kg). Results for normal/hypercapnia/hyperoxia conditions were: R2[s and -1] = 20.7/20.4/20.1, R2*[s and -1] = 31.6/29.6/25.9, R2'[s and 1] = 10.9/9.2/5.7, qBOLD venous blood oxygenation level = 0.43/0.51/0.56, CBF[ml.min and -1.100g and -1] = 70.6/105.5/81.8, Laser-Doppler flowmetry[a.u.] = 89.2/120.2/90.6 and pO2[mmHg] = 6.3/32.3/46.7. All parameters were statistically significantly different with P < 0.001 between all breathing conditions. All MRI and the corresponding micro probe measurements were also statistically significantly (P ≤ 0.03) correlated with each other. However, converting the tissue pO2 to blood oxygen saturation = 0.02/0.34/0.63, showed only very limited agreement with the qBOLD venous blood oxygenation level. We found good

  6. Correlation of oxygenation and perfusion sensitive MRI with invasive micro probe measurements in healthy mice brain

    Energy Technology Data Exchange (ETDEWEB)

    Sedlacik, Jan; Fiehler, Jens [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Neuroradiology; Reitz, Matthias; Schmidt, Nils O. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Neurosurgery; Bolar, Divya S. [Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States). Radiology; Adalsteinsson, Elfar [Massachusetts Institute of Technology, Cambridge, MA (United States). Electrical Engineering and Computer Science

    2015-05-01

    The non-invasive assessment of (patho-)physiological parameters such as, perfusion and oxygenation, is of great importance for the characterization of pathologies e.g., tumors, which may be helpful to better predict treatment response and potential outcome. To better understand the influence of physiological parameters on the investigated oxygenation and perfusion sensitive MRI methods, MRI measurements were correlated with subsequent invasive micro probe measurements during free breathing conditions of air, air+10% CO2 and 100% O2 in healthy mice brain. MRI parameters were the irreversible (R2), reversible (R2') and effective (R2*) transverse relaxation rates, venous blood oxygenation level assessed by quantitative blood oxygenation level dependent (qBOLD) method and cerebral blood flow (CBF) assessed by arterial spin labeling (ASL) using a 7T small animal MRI scanner. One to two days after MRI, tissue perfusion and pO2 were measured by Laser-Doppler flowmetry and fluorescence quenching micro probes, respectively. The tissue pO2 values were converted to blood oxygen saturation by using the Hill equation. The animals were anesthetized by intra peritoneal injection of ketamine-xylazine-acepromazine (10-2-0.3 mg/ml.kg). Results for normal/hypercapnia/hyperoxia conditions were: R2[s {sup and} -1] = 20.7/20.4/20.1, R2*[s {sup and} -1] = 31.6/29.6/25.9, R2'[s {sup and} 1] = 10.9/9.2/5.7, qBOLD venous blood oxygenation level = 0.43/0.51/0.56, CBF[ml.min {sup and} -1.100g {sup and} -1] = 70.6/105.5/81.8, Laser-Doppler flowmetry[a.u.] = 89.2/120.2/90.6 and pO2[mmHg] = 6.3/32.3/46.7. All parameters were statistically significantly different with P < 0.001 between all breathing conditions. All MRI and the corresponding micro probe measurements were also statistically significantly (P ≤ 0.03) correlated with each other. However, converting the tissue pO2 to blood oxygen saturation = 0.02/0.34/0.63, showed only very limited agreement with the qBOLD venous blood

  7. Labeling of mesenchymal stem cells for MRI with single-cell sensitivity

    Directory of Open Access Journals (Sweden)

    Ariza de Schellenberger A

    2016-04-01

    Full Text Available Angela Ariza de Schellenberger,1 Harald Kratz,1 Tracy D Farr,2,3 Norbert Löwa,4 Ralf Hauptmann,1 Susanne Wagner,1 Matthias Taupitz,1 Jörg Schnorr,1 Eyk A Schellenberger1 1Department of Radiology, 2Department of Experimental Neurology, Center for Stroke Research Berlin, Charité – Universitätsmedizin Berlin, Berlin, Germany; 3School of Life Sciences, University of Nottingham, Medical School, Nottingham, UK; 4Department of Biomagnetic Signals, Physikalisch-Technische Bundesanstalt Berlin, Berlin, Germany Abstract: Sensitive cell detection by magnetic resonance imaging (MRI is an important tool for the development of cell therapies. However, clinically approved contrast agents that allow single-cell detection are currently not available. Therefore, we compared very small iron oxide nanoparticles (VSOP and new multicore carboxymethyl dextran-coated iron oxide nanoparticles (multicore particles, MCP designed by our department for magnetic particle imaging (MPI with discontinued Resovist® regarding their suitability for detection of single mesenchymal stem cells (MSC by MRI. We achieved an average intracellular nanoparticle (NP load of >10 pg Fe per cell without the use of transfection agents. NP loading did not lead to significantly different results in proliferation, colony formation, and multilineage in vitro differentiation assays in comparison to controls. MRI allowed single-cell detection using VSOP, MCP, and Resovist® in conjunction with high-resolution T2*-weighted imaging at 7 T with postprocessing of phase images in agarose cell phantoms and in vivo after delivery of 2,000 NP-labeled MSC into mouse brains via the left carotid artery. With optimized labeling conditions, a detection rate of ~45% was achieved; however, the experiments were limited by nonhomogeneous NP loading of the MSC population. Attempts should be made to achieve better cell separation for homogeneous NP loading and to thus improve NP

  8. Integrated imaging using MRI and 123I metaiodobenzylguanidine scintigraphy to improve sensitivity and specificity in the diagnosis of pediatric neuroblastoma.

    Science.gov (United States)

    Pfluger, Thomas; Schmied, Christoph; Porn, Ute; Leinsinger, Gerda; Vollmar, Christian; Dresel, Stefan; Schmid, Irene; Hahn, Klaus

    2003-10-01

    The objectives of this study were to compare MRI and iodine-123 ((123)I) metaiodobenzylguanidine (MIBG) scintigraphy in the detection of neuroblastoma lesions in pediatric patients and to assess the additional value of combined imaging. Fifty MRI and 50 (123)I MIBG examinations (mean interval, 6.4 days) were analyzed retrospectively with regard to suspected or proven neuroblastoma lesions (n = 193) in 28 patients. MRI and MIBG scans were reviewed by two independent observers each. Separate and combined analyses of MRI and MIBG scintigraphy were compared with clinical and histologic findings. With regard to the diagnosis of neuroblastoma lesion, MIBG scintigraphy, MRI, and combined analysis showed a sensitivity of 69%, 86%, and 99% and a specificity of 85%, 77%, and 95%, respectively. On MRI, 15 false-positive findings were recorded: posttherapeutic reactive changes (n = 10), benign adrenal tumors (n = 3), and enlarged lymph nodes (n = 2). On MIBG scintigraphy, 10 false-positive findings occurred: ganglioneuromas (n = 2), benign liver tumors (n = 2), and physiologic uptake (n = 6). Thirteen neuroblastoma metastases and two residual masses under treatment with chemotherapy were judged to be false-negative findings on MRI. Two primary or residual neuroblastomas and one orbital metastasis were misinterpreted as Wilms' tumor, reactive changes after surgery, and rhabdomyosarcoma on MRI. Thirty-two bone metastases, six other neuroblastoma metastases, and one adrenal neuroblastoma showed no MIBG uptake. On combined imaging, one false-negative (bone metastasis) and three false-positive (two ganglioneuromas and one pheochromocytoma) findings remained. In the assessment of neuroblastoma lesions in pediatric patients, MRI showed a higher sensitivity and MIBG scintigraphy a higher specificity. However, integrated imaging showed an increase in both sensitivity and specificity.

  9. Picomolar-affinity binding and inhibition of adenylate cyclase activity by melatonin in Syrian hamster hypothalamus

    International Nuclear Information System (INIS)

    Niles, L.P.; Hashemi, F.

    1990-01-01

    1. The effect of melatonin on forskolin-stimulated adenylate cyclase activity was measured in homogenates of Syrian hamster hypothalamus. In addition, the saturation binding characteristics of the melatonin receptor ligand, [ 125 I]iodomelatonin, was examined using an incubation temperature (30 degree C) similar to that used in enzyme assays. 2. At concentrations ranging from 10 pM to 1 nM, melatonin caused a significant decrease in stimulated adenylate cyclase activity with a maximum inhibition of approximately 22%. 3. Binding experiments utilizing [ 125 I]iodomelatonin in a range of approximately 5-80 pM indicated a single class of high-affinity sites: Kd = 55 +/- 9 pM, Bmax = 1.1 +/- 0.3 fmol/mg protein. 4. The ability of picomolar concentrations of melatonin to inhibit forskolin-stimulated adenylate cyclase activity suggests that this affect is mediated by picomolar-affinity receptor binding sites for this hormone in the hypothalamus

  10. Sensitivity and specificity of CT- and MRI-scanning in evaluation of occult fracture of the proximal femur

    DEFF Research Database (Denmark)

    Haubro, M; Stougaard, C; Torfing, T

    2015-01-01

    AND METHODS: 67 patients (27 males, 40 females, mean age 80.5) seen in the emergency room with hip pain after fall, inability to stand and a primary X-ray without fracture were evaluated with both CT and MRI. The images were analysed by a senior consulting musculoskeletal radiologist, a resident in radiology...... and a resident in orthopaedic surgery. Sensitivity and specificity were estimated with MRI as the golden standard. Kappa value was used to assess level of agreement in both MRI and CT finding. RESULTS: 15 fractures of the proximal femur were found (7 intertrochanteric-, 3 femoral neck and 5 fractures...

  11. Relative sensitivities of DCE-MRI pharmacokinetic parameters to arterial input function (AIF) scaling.

    Science.gov (United States)

    Li, Xin; Cai, Yu; Moloney, Brendan; Chen, Yiyi; Huang, Wei; Woods, Mark; Coakley, Fergus V; Rooney, William D; Garzotto, Mark G; Springer, Charles S

    2016-08-01

    Dynamic-Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) has been used widely for clinical applications. Pharmacokinetic modeling of DCE-MRI data that extracts quantitative contrast reagent/tissue-specific model parameters is the most investigated method. One of the primary challenges in pharmacokinetic analysis of DCE-MRI data is accurate and reliable measurement of the arterial input function (AIF), which is the driving force behind all pharmacokinetics. Because of effects such as inflow and partial volume averaging, AIF measured from individual arteries sometimes require amplitude scaling for better representation of the blood contrast reagent (CR) concentration time-courses. Empirical approaches like blinded AIF estimation or reference tissue AIF derivation can be useful and practical, especially when there is no clearly visible blood vessel within the imaging field-of-view (FOV). Similarly, these approaches generally also require magnitude scaling of the derived AIF time-courses. Since the AIF varies among individuals even with the same CR injection protocol and the perfect scaling factor for reconstructing the ground truth AIF often remains unknown, variations in estimated pharmacokinetic parameters due to varying AIF scaling factors are of special interest. In this work, using simulated and real prostate cancer DCE-MRI data, we examined parameter variations associated with AIF scaling. Our results show that, for both the fast-exchange-limit (FXL) Tofts model and the water exchange sensitized fast-exchange-regime (FXR) model, the commonly fitted CR transfer constant (K(trans)) and the extravascular, extracellular volume fraction (ve) scale nearly proportionally with the AIF, whereas the FXR-specific unidirectional cellular water efflux rate constant, kio, and the CR intravasation rate constant, kep, are both AIF scaling insensitive. This indicates that, for DCE-MRI of prostate cancer and possibly other cancers, kio and kep may be more suitable imaging

  12. Picomolar selective detection of mercuric ion (Hg{sup 2+}) using a functionalized single plasmonic gold nanoparticle

    Energy Technology Data Exchange (ETDEWEB)

    Song, Hyeon Don; Choi, Inhee; Yang, Young In; Hong, Surin; Lee, Suseung; Yi, Jongheop [School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul 151-742 (Korea, Republic of); Kang, Taewook, E-mail: xinly601@snu.ac.kr, E-mail: iniini79@snu.ac.kr, E-mail: netmo00@snu.ac.kr, E-mail: pell2004@snu.ac.kr, E-mail: jazz1863@snu.ac.kr, E-mail: twkang@sogang.ac.kr, E-mail: jyi@snu.ac.kr [Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 121-742 (Korea, Republic of)

    2010-04-09

    A highly sensitive method for the selective detection and quantification of mercuric ions (Hg{sup 2+}) using single plasmonic gold nanoparticle (GNP)-based dark-field microspectroscopy (DFMS) is demonstrated. The method is based on the scattering property of a single GNP that is functionalized with thiolated molecules, which is altered when analytes bind to the functionalized GNP. The spectral resolution of the system is 0.26 nm and a linear response to Hg{sup 2+} was found in the dynamic range of 100 pM-10 {mu}M. The method permits Hg{sup 2+} to be detected at the picomolar level, which is a remarkable reduction in the detection limit, considering the currently proscribed Environmental Protection Agency regulation level (10 nM, or 2 ppb) and the detection limits of other optical methods for detecting Hg{sup 2+} (recently approx. 1-10 nM). In addition, Hg{sup 2+} can be sensitively detected in the presence of Cd{sup 2+}, Pb{sup 2+}, Cu{sup 2+}, Zn{sup 2+} and Ni{sup 2+}, which do not interfere with the analysis. Based on the findings reported herein, it is likely that single-nanoparticle-based metal ion sensing can be extended to the development of other chemo- and biosensors for the direct detection of specific targets in an intracellular environment as well as in environmental monitoring.

  13. MUSIC. a fast T2* - sensitive MRI technique with enhanced volume coverage

    International Nuclear Information System (INIS)

    Loenneker, Thomas; Hennig, Juergen

    1994-01-01

    A fast imaging method based on gradient-recalled echoes and echo time inter-leaved multi-slice excitation is presented. This method maintains the sensitivity of T 2 * by using a long echo time of at least 35 milliseconds. Bipolar gradients are used to shift the gradient echoes in order to ensure constant TE for each slab and prevent ghost-artefacts within the images caused by spin- or stimulated echoes. This method enhances the total imaging time of a conventional multi-slice gradient echo technique, while maintaining the high volume coverage. Thus, stimulated human cortical activation maps can be detected on standard clinical MR instruments at several planes within measuring times of a few seconds. The efficiency of the technique is demonstrated in the detection of temporary changes in T 2 * in functional MRI experiments of the human visual cortex at a magnetic field strength of 2 tesla. (author). 18 refs., 6 figs

  14. Adaptive smoothing based on Gaussian processes regression increases the sensitivity and specificity of fMRI data.

    Science.gov (United States)

    Strappini, Francesca; Gilboa, Elad; Pitzalis, Sabrina; Kay, Kendrick; McAvoy, Mark; Nehorai, Arye; Snyder, Abraham Z

    2017-03-01

    Temporal and spatial filtering of fMRI data is often used to improve statistical power. However, conventional methods, such as smoothing with fixed-width Gaussian filters, remove fine-scale structure in the data, necessitating a tradeoff between sensitivity and specificity. Specifically, smoothing may increase sensitivity (reduce noise and increase statistical power) but at the cost loss of specificity in that fine-scale structure in neural activity patterns is lost. Here, we propose an alternative smoothing method based on Gaussian processes (GP) regression for single subjects fMRI experiments. This method adapts the level of smoothing on a voxel by voxel basis according to the characteristics of the local neural activity patterns. GP-based fMRI analysis has been heretofore impractical owing to computational demands. Here, we demonstrate a new implementation of GP that makes it possible to handle the massive data dimensionality of the typical fMRI experiment. We demonstrate how GP can be used as a drop-in replacement to conventional preprocessing steps for temporal and spatial smoothing in a standard fMRI pipeline. We present simulated and experimental results that show the increased sensitivity and specificity compared to conventional smoothing strategies. Hum Brain Mapp 38:1438-1459, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Emotional sensitivity, emotion regulation and impulsivity in borderline personality disorder : a critical review of fMRI studies

    NARCIS (Netherlands)

    van Zutphen, Linda; Siep, Nicolette; Jacob, Gitta A; Goebel, R.; Arntz, Arnoud

    Emotional sensitivity, emotion regulation and impulsivity are fundamental topics in research of borderline personality disorder (BPD). Studies using fMRI examining the neural correlates concerning these topics is growing and has just begun understanding the underlying neural correlates in BPD.

  16. Sensitivity of MRI tumor biomarkers to VEGFR inhibitor therapy in an orthotopic mouse glioma model.

    Directory of Open Access Journals (Sweden)

    Christian T Farrar

    Full Text Available MRI biomarkers of tumor edema, vascular permeability, blood volume, and average vessel caliber are increasingly being employed to assess the efficacy of tumor therapies. However, the dependence of these biomarkers on a number of physiological factors can compromise their sensitivity and complicate the assessment of therapeutic efficacy. Here we examine the response of these MRI tumor biomarkers to cediranib, a potent vascular endothelial growth factor receptor (VEGFR inhibitor, in an orthotopic mouse glioma model. A significant increase in the tumor volume and relative vessel caliber index (rVCI and a slight decrease in the water apparent diffusion coefficient (ADC were observed for both control and cediranib treated animals. This contrasts with a clinical study that observed a significant decrease in tumor rVCI, ADC and volume with cediranib therapy. While the lack of a difference between control and cediranib treated animals in these biomarker responses might suggest that cediranib has no therapeutic benefit, cediranib treated mice had a significantly increased survival. The increased survival benefit of cediranib treated animals is consistent with the significant decrease observed for cediranib treated animals in the relative cerebral blood volume (rCBV, relative microvascular blood volume (rMBV, transverse relaxation time (T2, blood vessel permeability (K(trans, and extravascular-extracellular space (ν(e. The differential response of pre-clinical and clinical tumors to cediranib therapy, along with the lack of a positive response for some biomarkers, indicates the importance of evaluating the whole spectrum of different tumor biomarkers to properly assess the therapeutic response and identify and interpret the therapy-induced changes in the tumor physiology.

  17. Ex-vivo diffusion MRI reveals microstructural alterations in stress-sensitive brain regions: A chronic mild stress recovery study

    DEFF Research Database (Denmark)

    Khan, Ahmad Raza; Hansen, Brian; Wiborg, Ove

    Depression is a leading cause of disability worldwide and causes significant microstructural alterations in stress-sensitive brain regions. However, the potential recovery of these microstructural alterations has not previously been investigated, which we, therefore, set out to do using diffusion...... MRI (d-MRI) in the chronic mild stress (CMS) rat model of depression. This study reveals significant microstructural alterations after 8 weeks of recovery, in the opposite direction to change induced by stress in the acute phase of the experiment. Such findings may be useful in the prognosis...... of depression or for monitoring treatment response....

  18. Sensitivity of quantitative UTE MRI to the biomechanical property of the temporomandibular joint disc

    International Nuclear Information System (INIS)

    Bae, Won C.; Biswas, Reni; Statum, Sheronda; Sah, Robert L.; Chung, Christine B.

    2014-01-01

    To quantify MR properties of discs from cadaveric human temporomandibular joints (TMJ) using quantitative conventional and ultrashort time-to-echo magnetic resonance imaging (UTE MRI) techniques and to corroborate regional variation in the MR properties with that of biomechanical indentation stiffness. This study was exempt from the institutional review board approval. Cadaveric (four donors, two females, 74 ± 10.7 years) TMJs were sliced (n = 14 slices total) sagittally and imaged using quantitative techniques of conventional spin echo T2 (SE T2), UTE T2*, and UTE T1rho. The discs were then subjected to biomechanical indentation testing, which is performed by compressing the tissue with the blunt end of a small solid cylinder. Regional variations in MR and indentation stiffness were correlated. TMJ of a healthy volunteer was also imaged to show in vivo feasibility. Using the ME SE T2 and the UTE T1rho techniques, a significant (each p 2 = 0.42) than SE T2 (R 2 = 0.19) or UTE T2* (R 2 = 0.02, p = 0.1) techniques. The UTE T1rho technique, applicable in vivo, facilitated quantitative evaluation of TMJ discs and showed a high sensitivity to biomechanical softening of the TMJ discs. With additional work, the technique may become a useful surrogate measure for loss of biomechanical integrity of TMJ discs reflecting degeneration. (orig.)

  19. Sensitivity and specificity considerations for fMRI encoding, decoding, and mapping of auditory cortex at ultra-high field.

    Science.gov (United States)

    Moerel, Michelle; De Martino, Federico; Kemper, Valentin G; Schmitter, Sebastian; Vu, An T; Uğurbil, Kâmil; Formisano, Elia; Yacoub, Essa

    2018-01-01

    Following rapid technological advances, ultra-high field functional MRI (fMRI) enables exploring correlates of neuronal population activity at an increasing spatial resolution. However, as the fMRI blood-oxygenation-level-dependent (BOLD) contrast is a vascular signal, the spatial specificity of fMRI data is ultimately determined by the characteristics of the underlying vasculature. At 7T, fMRI measurement parameters determine the relative contribution of the macro- and microvasculature to the acquired signal. Here we investigate how these parameters affect relevant high-end fMRI analyses such as encoding, decoding, and submillimeter mapping of voxel preferences in the human auditory cortex. Specifically, we compare a T 2 * weighted fMRI dataset, obtained with 2D gradient echo (GE) EPI, to a predominantly T 2 weighted dataset obtained with 3D GRASE. We first investigated the decoding accuracy based on two encoding models that represented different hypotheses about auditory cortical processing. This encoding/decoding analysis profited from the large spatial coverage and sensitivity of the T 2 * weighted acquisitions, as evidenced by a significantly higher prediction accuracy in the GE-EPI dataset compared to the 3D GRASE dataset for both encoding models. The main disadvantage of the T 2 * weighted GE-EPI dataset for encoding/decoding analyses was that the prediction accuracy exhibited cortical depth dependent vascular biases. However, we propose that the comparison of prediction accuracy across the different encoding models may be used as a post processing technique to salvage the spatial interpretability of the GE-EPI cortical depth-dependent prediction accuracy. Second, we explored the mapping of voxel preferences. Large-scale maps of frequency preference (i.e., tonotopy) were similar across datasets, yet the GE-EPI dataset was preferable due to its larger spatial coverage and sensitivity. However, submillimeter tonotopy maps revealed biases in assigned frequency

  20. Stress-sensitive arterial hypertension, haemodynamic changes and brain metabolites in hypertensive ISIAH rats: MRI investigation.

    Science.gov (United States)

    Seryapina, A A; Shevelev, O B; Moshkin, M P; Markel, A L; Akulov, A E

    2017-05-01

    What is the central question of this study? Stress-sensitive arterial hypertension is considered to be controlled by changes in central and peripheral sympathetic regulating mechanisms, which eventually result in haemodynamic alterations and blood pressure elevation. Therefore, study of the early stages of development of hypertension is of particular interest, because it helps in understanding the aetiology of the disease. What is the main finding and its importance? Non-invasive in vivo investigation in ISIAH rats demonstrated that establishment of sustainable stress-sensitive hypertension is accompanied by a decrease in prefrontal cortex activity and mobilization of hypothalamic processes, with considerable correlations between haemodynamic parameters and individual metabolite ratios. The study of early development of arterial hypertension in association with emotional stress is of great importance for better understanding of the aetiology and pathogenesis of the hypertensive disease. Magnetic resonance imaging (MRI) was applied to evaluate the changes in haemodynamics and brain metabolites in 1- and 3-month-old inherited stress-induced arterial hypertension (ISIAH) rats (10 male rats) with stress-sensitive arterial hypertension and in control normotensive Wistar Albino Glaxo (WAG) rats (eight male rats). In the 3-month-old ISIAH rats, the age-dependent increase in blood pressure was associated with increased blood flow through the renal arteries and decreased blood flow in the lower part of the abdominal aorta. The renal vascular resistance in the ISIAH rats decreased during ageing, although at both ages it remained higher than the renal vascular resistance in WAG rats. An integral metabolome portrait demonstrated that development of hypertension in the ISIAH rats was associated with an attenuation of the excitatory and energetic activity in the prefrontal cortex, whereas in the WAG rats the opposite age-dependent changes were observed. In contrast, in the

  1. Computational discovery of picomolar Q(o) site inhibitors of cytochrome bc1 complex.

    Science.gov (United States)

    Hao, Ge-Fei; Wang, Fu; Li, Hui; Zhu, Xiao-Lei; Yang, Wen-Chao; Huang, Li-Shar; Wu, Jia-Wei; Berry, Edward A; Yang, Guang-Fu

    2012-07-11

    A critical challenge to the fragment-based drug discovery (FBDD) is its low-throughput nature due to the necessity of biophysical method-based fragment screening. Herein, a method of pharmacophore-linked fragment virtual screening (PFVS) was successfully developed. Its application yielded the first picomolar-range Q(o) site inhibitors of the cytochrome bc(1) complex, an important membrane protein for drug and fungicide discovery. Compared with the original hit compound 4 (K(i) = 881.80 nM, porcine bc(1)), the most potent compound 4f displayed 20 507-fold improved binding affinity (K(i) = 43.00 pM). Compound 4f was proved to be a noncompetitive inhibitor with respect to the substrate cytochrome c, but a competitive inhibitor with respect to the substrate ubiquinol. Additionally, we determined the crystal structure of compound 4e (K(i) = 83.00 pM) bound to the chicken bc(1) at 2.70 Å resolution, providing a molecular basis for understanding its ultrapotency. To our knowledge, this study is the first application of the FBDD method in the discovery of picomolar inhibitors of a membrane protein. This work demonstrates that the novel PFVS approach is a high-throughput drug discovery method, independent of biophysical screening techniques.

  2. Ultra-sensitive molecular MRI of cerebrovascular cell activation enables early detection of chronic central nervous system disorders

    International Nuclear Information System (INIS)

    Montagne, Axel; Gauberti, Maxime; Jullienne, Amandine; Briens, Aurelien; Docagne, Fabian; Vivien, Denis; Maubert, Eric; Macrez, Richard; Defer, Gilles; Raynaud, Jean-Sebastien; Louin, Gaelle; Buisson, Alain; Haelewyn, Benoit

    2012-01-01

    Since endothelial cells can be targeted by large contrast-carrying particles, molecular imaging of cerebrovascular cell activation is highly promising to evaluate the underlying inflammation of the central nervous system (CNS). In this study, we aimed to demonstrate that molecular magnetic resonance imaging (MRI) of cerebrovascular cell activation can reveal CNS disorders in the absence of visible lesions and symptoms. To this aim, we optimized contrast carrying particles targeting vascular cell adhesion molecule-1 and MRI protocols through both in vitro and in vivo experiments. Although, pre-contrast MRI images failed to reveal the ongoing pathology, contrast-enhanced MRI revealed hypoperfusion-triggered CNS injury in vascular dementia, unmasked amyloid-induced cerebrovascular activation in Alzheimer's disease and allowed monitoring of disease activity during experimental autoimmune encephalomyelitis. Moreover, contrast-enhanced MRI revealed the cerebrovascular cell activation associated with known risk factors of CNS disorders such as peripheral inflammation, ethanol consumption, hyperglycemia and aging. By providing a dramatically higher sensitivity than previously reported methods and molecular contrast agents, the technology described in the present study opens new avenues of investigation in the field of neuro-inflammation. (authors)

  3. Sensitivity of quantitative UTE MRI to the biomechanical property of the temporomandibular joint disc

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Won C.; Biswas, Reni; Statum, Sheronda [University of California-San Diego, Department of Radiology, San Diego, CA (United States); Sah, Robert L. [University of California-San Diego, Department of Bioengineering, La Jolla, CA (United States); Chung, Christine B. [University of California-San Diego, Department of Radiology, San Diego, CA (United States); VA San Diego Healthcare System, Department of Radiology, San Diego, CA (United States)

    2014-09-15

    To quantify MR properties of discs from cadaveric human temporomandibular joints (TMJ) using quantitative conventional and ultrashort time-to-echo magnetic resonance imaging (UTE MRI) techniques and to corroborate regional variation in the MR properties with that of biomechanical indentation stiffness. This study was exempt from the institutional review board approval. Cadaveric (four donors, two females, 74 ± 10.7 years) TMJs were sliced (n = 14 slices total) sagittally and imaged using quantitative techniques of conventional spin echo T2 (SE T2), UTE T2*, and UTE T1rho. The discs were then subjected to biomechanical indentation testing, which is performed by compressing the tissue with the blunt end of a small solid cylinder. Regional variations in MR and indentation stiffness were correlated. TMJ of a healthy volunteer was also imaged to show in vivo feasibility. Using the ME SE T2 and the UTE T1rho techniques, a significant (each p < 0.0001) inverse relation between MR and indentation stiffness properties was observed for the data in the lower range of stiffness. However, the strength of correlation was significantly higher (p < 0.05) for UTE T1rho (R{sup 2} = 0.42) than SE T2 (R{sup 2} = 0.19) or UTE T2* (R{sup 2} = 0.02, p = 0.1) techniques. The UTE T1rho technique, applicable in vivo, facilitated quantitative evaluation of TMJ discs and showed a high sensitivity to biomechanical softening of the TMJ discs. With additional work, the technique may become a useful surrogate measure for loss of biomechanical integrity of TMJ discs reflecting degeneration. (orig.)

  4. Rice Seed Priming with Picomolar Rutin Enhances Rhizospheric Bacillus subtilis CIM Colonization and Plant Growth.

    Directory of Open Access Journals (Sweden)

    Akanksha Singh

    Full Text Available The effect of rutin, a bioflavonoid on the growth and biofilm formation of Bacillus subtilis strain CIM was investigated. In addition to swimming, swarming, and twitching potentials of B. subtilis CIM (BS, one picomolar (1 pM of rutin was also observed to boost the biofilm forming ability of the bacterium. Bio-priming of rice seeds with BS and rutin not only augmented root and shoot lengths but also the photosynthetic pigments like chlorophyll and carotenoid. Similarly, high accumulation of phenolic and flavonoid contents was observed in the leaves. Fluorescent microscopic images revealed that BS plus rutin enhanced callose deposition in the leaves. It was also established that the least formation of reactive oxygen species in BS plus rutin treated rice plants was due to higher free radicals scavenging activity and total antioxidant potential. The results highlight chemo attractant nature of BS towards rutin, which by enhancing biofilm formation and root colonization indirectly strengthened the plants' defensive state.

  5. Glucose metabolism-weighted imaging with chemical exchange-sensitive MRI of 2-deoxyglucose (2DG) in brain: Sensitivity and biological sources.

    Science.gov (United States)

    Jin, Tao; Mehrens, Hunter; Wang, Ping; Kim, Seong-Gi

    2016-12-01

    Recent proof-of-principle studies have demonstrated the feasibility of measuring the uptake and metabolism of non-labeled 2-deoxy-D-glucose (2DG) by a chemical exchange-sensitive spin-lock (CESL) MRI approach. In order to gain better understanding of this new approach, we performed dynamic in vivo CESL MRI on healthy rat brains with an intravenous injection of 2DG under various conditions at 9.4T. For three 2DG doses of 0.25, 0.5 and 1g/kg, we found that 2DG-CESL signals increased linearly with injection dose at the initial (40min) suggesting time-dependent differential weightings of 2DG transport and metabolism. Remaining 2DG-CESL studies were performed with 0.25g/kg 2DG. Since a higher isoflurane level reduces glucose metabolism and increases blood flow, 2DG-CESL was measured under 0.5%, 1.5% and 2.2% isoflurane. The 2DG-CESL signal was reduced at higher isoflurane levels correlating well with the 2DG phosphorylation in the intracellular space. To detect regional heterogeneities of glucose metabolism, 2DG-CESL with 0.33×0.33×1.50mm 3 resolution was obtained, which indeed showed a higher response in the cortex compared to the corpus callosum. Lastly, unlike CESL MRI with the injection of non-transportable mannitol, the 2DG-CESL response decreased with an increased spin-lock pulse power confirming that 2DG-CESL is dominated by chemical exchange processes in the extravascular space. Taken together, our results showed that 2DG-CESL MRI signals mainly indicate glucose transport and metabolism and may be a useful biomarker for metabolic studies of normal and diseased brains. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. 3Tesla MRI surface coil: Is it sensitive for prostatic imaging??

    African Journals Online (AJOL)

    Mahmoud Agha

    2014-01-30

    Jan 30, 2014 ... MRI, in pre-sampling diagnosis of prostate cancer, in an attempt to use it ... approved by the ethics committee in Al-Mana General Hospital. ... scopy; NPV, negative predictive value; PACS, Picture archiving and ... Some inherited genes had been found to raise the risk for more ..... ciplinary perspective.

  7. Calcium-sensitive MRI contrast agents based on superparamagnetic iron oxide nanoparticles and calmodulin.

    Science.gov (United States)

    Atanasijevic, Tatjana; Shusteff, Maxim; Fam, Peter; Jasanoff, Alan

    2006-10-03

    We describe a family of calcium indicators for magnetic resonance imaging (MRI), formed by combining a powerful iron oxide nanoparticle-based contrast mechanism with the versatile calcium-sensing protein calmodulin and its targets. Calcium-dependent protein-protein interactions drive particle clustering and produce up to 5-fold changes in T2 relaxivity, an indication of the sensors' potency. A variant based on conjugates of wild-type calmodulin and the peptide M13 reports concentration changes near 1 microM Ca(2+), suitable for detection of elevated intracellular calcium levels. The midpoint and cooperativity of the response can be tuned by mutating the protein domains that actuate the sensor. Robust MRI signal changes are achieved even at nanomolar particle concentrations (calcium levels. When combined with technologies for cellular delivery of nanoparticulate agents, these sensors and their derivatives may be useful for functional molecular imaging of biological signaling networks in live, opaque specimens.

  8. Improved sensitivity and specificity for resting state and task fMRI with multiband multi-echo EPI compared to multi-echo EPI at 7T.

    NARCIS (Netherlands)

    Boyacioglu, R.; Schulz, J.; Koopmans, P.J.; Barth, M.; Norris, David Gordon

    2015-01-01

    A multiband multi-echo (MBME) sequence is implemented and compared to a matched standard multi-echo (ME) protocol to investigate the potential improvement in sensitivity and spatial specificity at 7 T for resting state and task fMRI. ME acquisition is attractive because BOLD sensitivity is less

  9. Sensitivity and reliability of language laterality assessment with a free reversed association task - a fMRI study

    International Nuclear Information System (INIS)

    Fesl, Gunther; Brueckmann, Hartmut; Bruhns, Philipp; Rau, Sabine; Ilmberger, Josef; Wiesmann, Martin; Kegel, Gerd

    2010-01-01

    The aim of the study was to evaluate the sensitivity and reliability of assessing hemispheric language dominance with functional magnetic resonance imaging (fMRI) using a 'free reversed association task.' Thirty-nine healthy subjects (13 dextrals, 13 sinistrals and 13 bimanuals) underwent two repeated fMRI sessions. In the active phases sets of words were presented via headphones, and an associated target item was named. During the baseline phases a standard answer was given after listening to unintelligible stimuli. Data were preprocessed with SPM, and then laterality indices (LI) and reliability coefficients (RC) were calculated. Extensive frontal, temporal and parietal activations were found. Seventy-eight percent of the subjects showed left-hemispheric dominance, 5% showed right-hemispheric dominance, and 17% had bilateral language representations. The incidence of right-hemispheric language dominance was 4.3 times higher in a left-hander with a handedness quotient (HQ) of -90 than in a right-hander with a HQ of +90. The RC was 0.61 for combined ROIs (global network). Strong correlations were found between the two session LIs (r = 0.95 for the global network). 'Free reversed association' is a sensitive and reliable task for the determination of individual language lateralization. This suggests that the task may be used in a clinical setting. (orig.)

  10. Sensitivity and reliability of language laterality assessment with a free reversed association task - a fMRI study

    Energy Technology Data Exchange (ETDEWEB)

    Fesl, Gunther; Brueckmann, Hartmut [University of Munich, Department of Neuroradiology, Campus Grosshadern, Marchioninistr. 15, 81377, Munich (Germany); Bruhns, Philipp [University of Munich, Department of Neuroradiology, Campus Grosshadern, Marchioninistr. 15, 81377, Munich (Germany); University of Munich, Department of Psycholinguistics, Munich (Germany); Rau, Sabine; Ilmberger, Josef [University of Munich, Department of Physical Medicine and Rehabilitation, Munich (Germany); Wiesmann, Martin [Helios Hospitals Schwerin, Department of Radiology and Neuroradiology, Schwerin (Germany); Kegel, Gerd [University of Munich, Department of Psycholinguistics, Munich (Germany)

    2010-03-15

    The aim of the study was to evaluate the sensitivity and reliability of assessing hemispheric language dominance with functional magnetic resonance imaging (fMRI) using a 'free reversed association task.' Thirty-nine healthy subjects (13 dextrals, 13 sinistrals and 13 bimanuals) underwent two repeated fMRI sessions. In the active phases sets of words were presented via headphones, and an associated target item was named. During the baseline phases a standard answer was given after listening to unintelligible stimuli. Data were preprocessed with SPM, and then laterality indices (LI) and reliability coefficients (RC) were calculated. Extensive frontal, temporal and parietal activations were found. Seventy-eight percent of the subjects showed left-hemispheric dominance, 5% showed right-hemispheric dominance, and 17% had bilateral language representations. The incidence of right-hemispheric language dominance was 4.3 times higher in a left-hander with a handedness quotient (HQ) of -90 than in a right-hander with a HQ of +90. The RC was 0.61 for combined ROIs (global network). Strong correlations were found between the two session LIs (r = 0.95 for the global network). 'Free reversed association' is a sensitive and reliable task for the determination of individual language lateralization. This suggests that the task may be used in a clinical setting. (orig.)

  11. Emotional sensitivity, emotion regulation and impulsivity in borderline personality disorder: a critical review of fMRI studies.

    Science.gov (United States)

    van Zutphen, Linda; Siep, Nicolette; Jacob, Gitta A; Goebel, Rainer; Arntz, Arnoud

    2015-04-01

    Emotional sensitivity, emotion regulation and impulsivity are fundamental topics in research of borderline personality disorder (BPD). Studies using fMRI examining the neural correlates concerning these topics is growing and has just begun understanding the underlying neural correlates in BPD. However, there are strong similarities but also important differences in results of different studies. It is therefore important to know in more detail what these differences are and how we should interpret these. In present review a critical light is shed on the fMRI studies examining emotional sensitivity, emotion regulation and impulsivity in BPD patients. First an outline of the methodology and the results of the studies will be given. Thereafter important issues that remained unanswered and topics to improve future research are discussed. Future research should take into account the limited power of previous studies and focus more on BPD specificity with regard to time course responses, different regulation strategies, manipulation of self-regulation, medication use, a wider range of stimuli, gender effects and the inclusion of a clinical control group. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Comparative sensitivities of functional MRI sequences in detection of local recurrence of prostate carcinoma after radical prostatectomy or external-beam radiotherapy.

    Science.gov (United States)

    Roy, Catherine; Foudi, Fatah; Charton, Jeanne; Jung, Michel; Lang, Hervé; Saussine, Christian; Jacqmin, Didier

    2013-04-01

    The aim of this retrospective study was to determine the respective accuracies of three types of functional MRI sequences-diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE) MRI, and 3D (1)H-MR spectroscopy (MRS)-in the depiction of local prostate cancer recurrence after two different initial therapy options. From a cohort of 83 patients with suspicion of local recurrence based on prostate-specific antigen (PSA) kinetics who were imaged on a 3-T MRI unit using an identical protocol including the three functional sequences with an endorectal coil, we selected 60 patients (group A, 28 patients who underwent radical prostatectomy; group B, 32 patients who underwent external-beam radiation) who had local recurrence ascertained on the basis of a transrectal ultrasound-guided biopsy results and a reduction in PSA level after salvage therapy. All patients presented with a local relapse. Sensitivity with T2-weighted MRI and 3D (1)H-MRS sequences was 57% and 53%, respectively, for group A and 71% and 78%, respectively, for group B. DCE-MRI alone showed a sensitivity of 100% and 96%, respectively, for groups A and B. DWI alone had a higher sensitivity for group B (96%) than for group A (71%). The combination of T2-weighted imaging plus DWI plus DCE-MRI provided a sensitivity as high as 100% in group B. The performance of functional imaging sequences for detecting recurrence is different after radical prostatectomy and external-beam radiotherapy. DCE-MRI is a valid and efficient tool to detect prostate cancer recurrence in radical prostatectomy as well as in external-beam radiotherapy. The combination of DCE-MRI and DWI is highly efficient after radiation therapy. Three-dimensional (1)H-MRS needs to be improved. Even though it is not accurate enough, T2-weighted imaging remains essential for the morphologic analysis of the area.

  13. Sensitivity analysis of brain morphometry based on MRI-derived surface models

    Science.gov (United States)

    Klein, Gregory J.; Teng, Xia; Schoenemann, P. T.; Budinger, Thomas F.

    1998-07-01

    Quantification of brain structure is important for evaluating changes in brain size with growth and aging and for characterizing neurodegeneration disorders. Previous quantification efforts using ex vivo techniques suffered considerable error due to shrinkage of the cerebrum after extraction from the skull, deformation of slices during sectioning, and numerous other factors. In vivo imaging studies of brain anatomy avoid these problems and allow repetitive studies following progression of brain structure changes due to disease or natural processes. We have developed a methodology for obtaining triangular mesh models of the cortical surface from MRI brain datasets. The cortex is segmented from nonbrain tissue using a 2D region-growing technique combined with occasional manual edits. Once segmented, thresholding and image morphological operations (erosions and openings) are used to expose the regions between adjacent surfaces in deep cortical folds. A 2D region- following procedure is then used to find a set of contours outlining the cortical boundary on each slice. The contours on all slices are tiled together to form a closed triangular mesh model approximating the cortical surface. This model can be used for calculation of cortical surface area and volume, as well as other parameters of interest. Except for the initial segmentation of the cortex from the skull, the technique is automatic and requires only modest computation time on modern workstations. Though the use of image data avoids many of the pitfalls of ex vivo and sectioning techniques, our MRI-based technique is still vulnerable to errors that may impact the accuracy of estimated brain structure parameters. Potential inaccuracies include segmentation errors due to incorrect thresholding, missed deep sulcal surfaces, falsely segmented holes due to image noise and surface tiling artifacts. The focus of this paper is the characterization of these errors and how they affect measurements of cortical surface

  14. fMRI study of neural sensitization to hedonic stimuli in long-term, daily cannabis users.

    Science.gov (United States)

    Filbey, Francesca M; Dunlop, Joseph; Ketcherside, Ariel; Baine, Jessica; Rhinehardt, Tyler; Kuhn, Brittany; DeWitt, Sam; Alvi, Talha

    2016-10-01

    Although there is emergent evidence illustrating neural sensitivity to cannabis cues in cannabis users, the specificity of this effect to cannabis cues as opposed to a generalized hyper-sensitivity to hedonic stimuli has not yet been directly tested. Using fMRI, we presented 53 daily, long-term cannabis users and 68 non-using controls visual and tactile cues for cannabis, a natural reward, and, a sensory-perceptual control object to evaluate brain response to hedonic stimuli in cannabis users. The results showed an interaction between group and reward type such that the users had greater response during cannabis cues relative to natural reward cues (i.e., fruit) in the orbitofrontal cortex, striatum, anterior cingulate gyrus, and ventral tegmental area compared to non-users (cluster-threshold z = 2.3, P brain-behavior correlations between neural response to cannabis cues in fronto-striatal-temporal regions and subjective craving, marijuana-related problems, withdrawal symptoms, and levels of THC metabolites (cluster-threshold z = 2.3, P brain response to cannabis cues in long-term cannabis users that are above that of response to natural reward cues. These observations are concordant with incentive sensitization models suggesting sensitization of mesocorticolimbic regions and disruption of natural reward processes following drug use. Although the cross-sectional nature of this study does not provide information on causality, the positive correlations between neural response and indicators of cannabis use (i.e., THC levels) suggest that alterations in the reward system are, in part, related to cannabis use. Hum Brain Mapp 37:3431-3443, 2016. © 2016 The Authors Human Brain Mapping Published by Wiley Periodicals, Inc. © 2016 The Authors Human Brain Mapping Published by Wiley Periodicals, Inc.

  15. fMRI study of neural sensitization to hedonic stimuli in long‐term, daily cannabis users

    Science.gov (United States)

    Dunlop, Joseph; Ketcherside, Ariel; Baine, Jessica; Rhinehardt, Tyler; Kuhn, Brittany; DeWitt, Sam; Alvi, Talha

    2016-01-01

    Abstract Although there is emergent evidence illustrating neural sensitivity to cannabis cues in cannabis users, the specificity of this effect to cannabis cues as opposed to a generalized hyper‐sensitivity to hedonic stimuli has not yet been directly tested. Using fMRI, we presented 53 daily, long‐term cannabis users and 68 non‐using controls visual and tactile cues for cannabis, a natural reward, and, a sensory‐perceptual control object to evaluate brain response to hedonic stimuli in cannabis users. The results showed an interaction between group and reward type such that the users had greater response during cannabis cues relative to natural reward cues (i.e., fruit) in the orbitofrontal cortex, striatum, anterior cingulate gyrus, and ventral tegmental area compared to non‐users (cluster‐threshold z = 2.3, P cannabis cues in fronto‐striatal‐temporal regions and subjective craving, marijuana‐related problems, withdrawal symptoms, and levels of THC metabolites (cluster‐threshold z = 2.3, P cannabis cues in long‐term cannabis users that are above that of response to natural reward cues. These observations are concordant with incentive sensitization models suggesting sensitization of mesocorticolimbic regions and disruption of natural reward processes following drug use. Although the cross‐sectional nature of this study does not provide information on causality, the positive correlations between neural response and indicators of cannabis use (i.e., THC levels) suggest that alterations in the reward system are, in part, related to cannabis use. Hum Brain Mapp 37:3431–3443, 2016. © 2016 The Authors Human Brain Mapping Published by Wiley Periodicals, Inc. PMID:27168331

  16. Diagnostic evaluation of a nanobody with picomolar affinity toward the protease RgpB from Porphyromonas gingivalis

    OpenAIRE

    Skottrup, Peter Durand; Leonard, Paul; Kaczmarek, Jakub Zbigniew; Veillard, Florian; Enghild, Jan Johannes; O'Kennedy, Richard; Sroka, Aneta; Clausen, Rasmus Praetorius; Potempa, Jan; Riise, Erik

    2011-01-01

    Porphyromonas gingivalis is one of the major periodontitis-causing pathogens. P. gingivalis secretes a group of proteases, termed gingipains, and in this study we have utilized the RgpB gingipain as a biomarker for P. gingivalis. We constructed a naïve camel nanobody library and used phage display to select one nanobody towards RgpB with picomolar affinity. The nanobody was used in an inhibition assay for detection of RgpB in buffer as well as in saliva. The nanobody was highly specific for R...

  17. Technique for measuring picomolar amounts of bound and unbound amino acids obtained from myogenic cell cultures of skeletal muscle

    International Nuclear Information System (INIS)

    Bullaro, J.C.

    1981-01-01

    A procedure is described that compares the isotope dilution method of measuring picomolar amounts of amino acids obtained from cellular extracts with a direct method of analysis. Evidence is provided that shows that the direct method is at least as accurate as the isotope dilution method. In addition the direct method is as expedient an requires but a single isotope and fewer chromatograms for analysis. A procedure also is described for selecting the appropriate conditions for dansylation and for measuring the loss of dansyl amino acid due to decomposition

  18. Bi-Directional Tuning of Amygdala Sensitivity in Combat Veterans Investigated with fMRI

    Science.gov (United States)

    Brashers-Krug, Tom; Jorge, Ricardo

    2015-01-01

    Objectives Combat stress can be followed by persistent emotional consequences. It is thought that these emotional consequences are caused in part by increased amygdala reactivity. It is also thought that amygdala hyper-reactivity results from decreased inhibition from portions of the anterior cingulate cortex (ACC) in which activity is negatively correlated with activity in the amygdala. However, experimental support for these proposals has been inconsistent. Methods We showed movies of combat and civilian scenes during a functional magnetic resonance imaging (fMRI) session to 50 veterans of recent combat. We collected skin conductance responses (SCRs) as measures of emotional arousal. We examined the relation of blood oxygenation-level dependent (BOLD) signal in the amygdala and ACC to symptom measures and to SCRs. Results Emotional arousal, as measured with SCR, was greater during the combat movie than during the civilian movie and did not depend on symptom severity. As expected, amygdala signal during the less-arousing movie increased with increasing symptom severity. Surprisingly, during the more-arousing movie amygdala signal decreased with increasing symptom severity. These differences led to the unexpected result that amygdala signal in highly symptomatic subjects was lower during the more-arousing movie than during the less-arousing movie. Also unexpectedly, we found no significant inverse correlation between any portions of the amygdala and ACC. Rather, signal throughout more than 80% of the ACC showed a strong positive correlation with signal throughout more than 90% of the amygdala. Conclusions Amygdala reactivity can be tuned bi-directionally, either up or down, in the same person depending on the stimulus and the degree of post-traumatic symptoms. The exclusively positive correlations in BOLD activity between the amygdala and ACC contrast with findings that have been cited as evidence for inhibitory control of the amygdala by the ACC. The

  19. Ultra-high field NMR and MRI - the role of magnet technology to increase sensitivity and specificity

    Science.gov (United States)

    Moser, Ewald; Laistler, Elmar; Schmitt, Franz; Kontaxis, Georg

    2017-08-01

    "History, of course, is difficult to write, if for no other reason, than that it has so many players and so many authors." - P. J. Keating (former Australian Prime Minister) Starting with post-war developments in nuclear magnetic resonance (NMR) a race for stronger and stronger magnetic fields has begun in the 1950s to overcome the inherently low sensitivity of this promising method. Further challenges were larger magnet bores to accommodate small animals and eventually humans. Initially, resistive electromagnets with small pole distances, or sample volumes, and field strengths up to 2.35 T (or 100 MHz 1H frequency) were used in applications in physics, chemistry, and material science. This was followed by stronger and more stable (NbTi based) superconducting magnet technology typically implemented first for small-bore systems in analytical chemistry, biochemistry and structural biology, and eventually allowing larger horizontal-bore magnets with diameters large enough to fit small laboratory animals. By the end of the 1970s, first low-field resistive magnets big enough to accommodate humans were developed and superconducting whole-body systems followed. Currently, cutting-edge analytical NMR systems are available at proton frequencies up to 1 GHz (23.5 T) based on Nb3Sn at 1.9 K. A new 1.2 GHz system (28 T) at 1.9 K, operating in persistent mode but using a combination of low and high temperature multi-filament superconductors is to be released. Preclinical instruments range from small-bore animal systems with typically 600 - 800 MHz (14.1 - 18.8 T) up to 900 MHz (21 T) at 1.9 K. Human whole-body MRI systems currently operate up to 10.5 T. Hybrid combined superconducting and resistive electromagnets with even higher field strength of 45 T dc and 100 T pulsed, are available for material research, of course with smaller free bore diameters. This rather costly development towards higher and higher field strength is a consequence of the inherently low and, thus

  20. Sensitivity encoded silicon photomultiplier—a new sensor for high-resolution PET-MRI

    International Nuclear Information System (INIS)

    Schulz, Volkmar; Berker, Yannick; Berneking, Arne; Omidvari, Negar; Kiessling, Fabian; Gola, Alberto; Piemonte, Claudio

    2013-01-01

    Detectors for simultaneous positron emission tomography and magnetic resonance imaging in particular with sub-mm spatial resolution are commonly composed of scintillator crystal arrays, readout via arrays of solid state sensors, such as avalanche photo diodes (APDs) or silicon photomultipliers (SiPMs). Usually a light guide between the crystals and the sensor is used to enable the identification of crystals which are smaller than the sensor elements. However, this complicates crystal identification at the gaps and edges of the sensor arrays. A solution is to use as many sensors as crystals with a direct coupling, which unfortunately increases the complexity and power consumption of the readout electronics. Since 1997, position-sensitive APDs have been successfully used to identify sub-mm crystals. Unfortunately, these devices show a limitation in their time resolution and a degradation of spatial resolution when placed in higher magnetic fields. To overcome these limitations, this paper presents a new sensor concept that extends conventional SiPMs by adding position information via the spatial encoding of the channel sensitivity. The concept allows a direct coupling of high-resolution crystal arrays to the sensor with a reduced amount of readout channels. The theory of sensitivity encoding is detailed and linked to compressed sensing to compute unique sparse solutions. Two devices have been designed using one- and two-dimensional linear sensitivity encoding with eight and four readout channels, respectively. Flood histograms of both devices show the capability to precisely identify all 4 × 4 LYSO crystals with dimensions of 0.93 × 0.93 × 10 mm 3 . For these crystals, the energy and time resolution (MV ± SD) of the devices with one (two)-dimensional encoding have been measured to be 12.3 · (1 ± 0.047)% (13.7 · (1 ± 0.047)%) around 511 keV with a paired coincidence time resolution (full width at half maximum) of 462 · (1 ± 0.054) ps (452 · (1 ± 0

  1. Sensitivity encoded silicon photomultiplier—a new sensor for high-resolution PET-MRI

    Science.gov (United States)

    Schulz, Volkmar; Berker, Yannick; Berneking, Arne; Omidvari, Negar; Kiessling, Fabian; Gola, Alberto; Piemonte, Claudio

    2013-07-01

    Detectors for simultaneous positron emission tomography and magnetic resonance imaging in particular with sub-mm spatial resolution are commonly composed of scintillator crystal arrays, readout via arrays of solid state sensors, such as avalanche photo diodes (APDs) or silicon photomultipliers (SiPMs). Usually a light guide between the crystals and the sensor is used to enable the identification of crystals which are smaller than the sensor elements. However, this complicates crystal identification at the gaps and edges of the sensor arrays. A solution is to use as many sensors as crystals with a direct coupling, which unfortunately increases the complexity and power consumption of the readout electronics. Since 1997, position-sensitive APDs have been successfully used to identify sub-mm crystals. Unfortunately, these devices show a limitation in their time resolution and a degradation of spatial resolution when placed in higher magnetic fields. To overcome these limitations, this paper presents a new sensor concept that extends conventional SiPMs by adding position information via the spatial encoding of the channel sensitivity. The concept allows a direct coupling of high-resolution crystal arrays to the sensor with a reduced amount of readout channels. The theory of sensitivity encoding is detailed and linked to compressed sensing to compute unique sparse solutions. Two devices have been designed using one- and two-dimensional linear sensitivity encoding with eight and four readout channels, respectively. Flood histograms of both devices show the capability to precisely identify all 4 × 4 LYSO crystals with dimensions of 0.93 × 0.93 × 10 mm3. For these crystals, the energy and time resolution (MV ± SD) of the devices with one (two)-dimensional encoding have been measured to be 12.3 · (1 ± 0.047)% (13.7 · (1 ± 0.047)%) around 511 keV with a paired coincidence time resolution (full width at half maximum) of 462 · (1 ± 0.054) ps (452 · (1 ± 0

  2. Sensitivity encoded silicon photomultiplier--a new sensor for high-resolution PET-MRI.

    Science.gov (United States)

    Schulz, Volkmar; Berker, Yannick; Berneking, Arne; Omidvari, Negar; Kiessling, Fabian; Gola, Alberto; Piemonte, Claudio

    2013-07-21

    Detectors for simultaneous positron emission tomography and magnetic resonance imaging in particular with sub-mm spatial resolution are commonly composed of scintillator crystal arrays, readout via arrays of solid state sensors, such as avalanche photo diodes (APDs) or silicon photomultipliers (SiPMs). Usually a light guide between the crystals and the sensor is used to enable the identification of crystals which are smaller than the sensor elements. However, this complicates crystal identification at the gaps and edges of the sensor arrays. A solution is to use as many sensors as crystals with a direct coupling, which unfortunately increases the complexity and power consumption of the readout electronics. Since 1997, position-sensitive APDs have been successfully used to identify sub-mm crystals. Unfortunately, these devices show a limitation in their time resolution and a degradation of spatial resolution when placed in higher magnetic fields. To overcome these limitations, this paper presents a new sensor concept that extends conventional SiPMs by adding position information via the spatial encoding of the channel sensitivity. The concept allows a direct coupling of high-resolution crystal arrays to the sensor with a reduced amount of readout channels. The theory of sensitivity encoding is detailed and linked to compressed sensing to compute unique sparse solutions. Two devices have been designed using one- and two-dimensional linear sensitivity encoding with eight and four readout channels, respectively. Flood histograms of both devices show the capability to precisely identify all 4 × 4 LYSO crystals with dimensions of 0.93 × 0.93 × 10 mm(3). For these crystals, the energy and time resolution (MV ± SD) of the devices with one (two)-dimensional encoding have been measured to be 12.3 · (1 ± 0.047)% (13.7 · (1 ± 0.047)%) around 511 keV with a paired coincidence time resolution (full width at half maximum) of 462 · (1 ± 0.054) ps (452 · (1 ± 0

  3. Relationships between reward sensitivity, risk-taking and family history of alcoholism during an interactive competitive fMRI task.

    Directory of Open Access Journals (Sweden)

    Haley L Yarosh

    Full Text Available Individuals with a positive family history for alcoholism (FHP have shown differences from family-history-negative (FHN individuals in the neural correlates of reward processing. FHP, compared to FHN individuals, demonstrate relatively diminished ventral striatal activation during anticipation of monetary rewards, and the degree of ventral striatal activation shows an inverse correlation with specific impulsivity measures in alcohol-dependent individuals. Rewards in socially interactive contexts relate importantly to addictive propensities, yet have not been examined with respect to how their neural underpinnings relate to impulsivity-related measures. Here we describe impulsivity measures in FHN and FHP individuals as they relate to a socially interactive functional magnetic resonance imaging (fMRI task.Forty FHP and 29 FHN subjects without histories of Axis-I disorders completed a socially interactive Domino task during functional magnetic resonance imaging and completed self-report and behavioral impulsivity-related assessments.FHP compared to FHN individuals showed higher scores (p = .004 on one impulsivity-related factor relating to both compulsivity (Padua Inventory and reward/punishment sensitivity (Sensitivity to Punishment/Sensitivity to Reward Questionnaire. Multiple regression analysis within a reward-related network revealed a correlation between risk-taking (involving another impulsivity-related factor, the Balloon Analog Risk Task (BART and right ventral striatum activation under reward >punishment contrast (p<0.05 FWE corrected in the social task.Behavioral risk-taking scores may be more closely associated with neural correlates of reward responsiveness in socially interactive contexts than are FH status or impulsivity-related self-report measures. These findings suggest that risk-taking assessments be examined further in socially interactive settings relevant to addictive behaviors.

  4. The resolution sensitivity of the Asian summer monsoon and its inter-model comparison between MRI-AGCM and MetUM

    Science.gov (United States)

    Ogata, Tomomichi; Johnson, Stephanie J.; Schiemann, Reinhard; Demory, Marie-Estelle; Mizuta, Ryo; Yoshida, Kohei; Osamu Arakawa

    2017-11-01

    In this study, we compare the resolution sensitivity of the Asian Summer Monsoon (ASM) in two Atmospheric General Circulation Models (AGCMs): the MRI-AGCM and the MetUM. We analyze the MetUM at three different resolutions, N96 (approximately 200-km mesh on the equator), N216 (90-km mesh) and N512 (40-km mesh), and the MRI-AGCM at TL95 (approximately 180-km mesh on the equator), TL319 (60-km mesh), and TL959 (20-km mesh). The MRI-AGCM and the MetUM both show decreasing precipitation over the western Pacific with increasing resolution, but their precipitation responses differ over the Indian Ocean. In MRI-AGCM, a large precipitation increase appears off the equator (5-20°N). In MetUM, this off-equatorial precipitation increase is less significant and precipitation decreases over the equator. Moisture budget analysis demonstrates that a changing in moisture flux convergence at higher resolution is related to the precipitation response. Orographic effects, intra-seasonal variability and the representation of the meridional thermal gradient are explored as possible causes of the resolution sensitivity. Both high-resolution AGCMs (TL959 and N512) can represent steep topography, which anchors the rainfall pattern over south Asia and the Maritime Continent. In MRI-AGCM, representation of low pressure systems in TL959 also contributes to the rainfall pattern. Furthermore, the seasonal evolution of the meridional thermal gradient appears to be more accurate at higher resolution, particularly in the MRI-AGCM. These findings emphasize that the impact of resolution is only robust across the two AGCMs for some features of the ASM, and highlights the importance of multi-model studies of GCM resolution sensitivity.

  5. Sensitivity and specificity of a new MRI method evaluating temporo-mandibular joint disc-condyle relationships: an in vivo study.

    Science.gov (United States)

    Benbelaïd, R; Fleiter, B

    2006-03-01

    The aim of this study was to evaluate sensitivity and specificity of a new method to locate temporo-mandibular joint (TMJ) disc using magnetic resonance imaging (MRI) and analyze disc-condyle relationships, in asymptomatic subjects and patients with disc displacement. Twenty-nine sagittal MRI of 16 subjects, 8 asymptomatic volunteers and 8 subjects with anterior disc displacement, were carried out during controlled opening from intercuspal position up to a 25 mm opening. Selected sections were analyzed with a graphic computerized system of coordinates. The total surface area (TS) of disc section was separated into anterior surface area (AS) and posterior surface area. Areas were determined by computer. Two trained examiners drew images at random. The reliability of AS/TS ratio index was evaluated in a previous study. AS/TS ratio sensitivity (Se) and specificity (Sp) were calculated closed mouth, 5 mm open and 25 mm open mouth. Best sensitivity (Se=0.63) and specificity (Sp=0.81) were obtained when MRI was realized with closed mouth and 25 mm open mouth. Lower sensitivity was observed when MRI was performed either with closed mouth (Se=0.54) or 25 mm open mouth (Se=0.18). Lower specificity was observed with 5 mm open mouth (Sp=0.68). In conclusion, it was confirmed as well that MRI of anterior disc displacement should be performed with closed mouth and opened mouth. Thus, further studies are required to assess disc displacement and mechanical alterations and to evaluate the risk of direct damage on TMJ tissues.

  6. Robust water fat separated dual-echo MRI by phase-sensitive reconstruction.

    Science.gov (United States)

    Romu, Thobias; Dahlström, Nils; Leinhard, Olof Dahlqvist; Borga, Magnus

    2017-09-01

    The purpose of this work was to develop and evaluate a robust water-fat separation method for T1-weighted symmetric two-point Dixon data. A method for water-fat separation by phase unwrapping of the opposite-phase images by phase-sensitive reconstruction (PSR) is introduced. PSR consists of three steps; (1), identification of clusters of tissue voxels; (2), unwrapping of the phase in each cluster by solving Poisson's equation; and (3), finding the correct sign of each unwrapped opposite-phase cluster, so that the water-fat images are assigned the correct identities. Robustness was evaluated by counting the number of water-fat swap artifacts in a total of 733 image volumes. The method was also compared to commercial software. In the water-fat separated image volumes, the PSR method failed to unwrap the phase of one cluster and misclassified 10. One swap was observed in areas affected by motion and was constricted to the affected area. Twenty swaps were observed surrounding susceptibility artifacts, none of which spread outside the artifact affected regions. The PSR method had fewer swaps when compared to commercial software. The PSR method can robustly produce water-fat separated whole-body images based on symmetric two-echo spoiled gradient echo images, under both ideal conditions and in the presence of common artifacts. Magn Reson Med 78:1208-1216, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  7. Sensitivity of whole-body CT and MRI versus projection radiography in the detection of osteolyses in patients with monoclonal plasma cell disease

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Maya B., E-mail: m.mueller-wolf@dkfz.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg Germany (Germany); Department of Radiology, German Cancer Research Center (Dkfz), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Murray, Fritz, E-mail: fritz.murray@hotmail.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg Germany (Germany); Kilk, Kerstin, E-mail: k_fechtner@hotmail.com [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg Germany (Germany); Hillengass, Jens, E-mail: jens.hillengass@med.uni-heidelberg.de [Department of Haematology, Oncology, Rheumatology, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120 Heidelberg (Germany); Delorme, Stefan, E-mail: s.delorme@dkfz-heidelberg.de [Department of Radiology, German Cancer Research Center (Dkfz), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Heiss, Christiane, E-mail: c.heiss@dkfz-heidelberg.de [Department of Biostatistics, German Cancer Research Center (Dkfz), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Neben, Kai, E-mail: k.neben@klinikum-mittelbaden.de [Department of Haematology, Oncology, Rheumatology, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120 Heidelberg (Germany); Goldschmidt, Hartmut, E-mail: hartmut.goldschmidt@med.uni-heidelberg.de [Department of Haematology, Oncology, Rheumatology, University Hospital Heidelberg and National Center for Tumour Diseases, Im Neuenheimer Feld 410, 69120 Heidelberg (Germany); Kauczor, Hans-Ulrich, E-mail: hu.kauczor@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg Germany (Germany); and others

    2014-07-15

    Purpose: To compare sensitivity of whole-body Computed Tomography (wb-CT) and whole-body Magnetic Resonance Imaging (wb-MRI) with Projection Radiography (PR) regarding each method's ability to detect osteolyses in patients with monoclonal plasma cell disease. Patients and methods: The bone status of 171 patients was evaluated. All patients presented with multiple myeloma (MM) of all stages, monoclonal gammopathy of unknown significance (MGUS) or solitary plasmacytoma. Two groups were formed. Group A consisted of 52 patients (26 females, 26 males) with an average age of 62 years (range, 45–89 years) who received, both, PR and wb-CT as part of their diagnostic work-up. Group B comprised 119 patients (58 females, 61 males) averaging 57 years of age (range, 20–80 years) who received, both, PR and wb-MRI. Two experienced radiologists were blinded regarding the disease status and assessed the number and location of osteolyses in consensus. A distinction was made between axial and extra-axial lesions. Results: In group A, wb-CT revealed osteolyses in 12 patients (23%) that were not detected in PR. CT was superior in detecting lesions in patients with osteopenia and osteoporosis. Compared with PR, wb-CT was significantly more sensitive in detecting osteolyses than PR (p < 0.001). This was particularly true for axial lesions. Additionally, CT revealed clinically relevant incidental findings in 33 patients (63%). In group B, wb-MRI revealed lesions in 19 patients (16%) that were not detected in PR. All lesions detected by PR were also detected by wb-MRI and wb-CT. Wb-MRI and wb-CT are each superior to PR in detecting axial lesions. Conclusion: Wb-CT can detect 23% more focal lesions than PR, especially in the axial skeleton. Therefore, this imaging method should be preferred over PR in the diagnostic work-up and staging of patients with monoclonal plasma cell disease.

  8. Engineering an antibody with picomolar affinity to DOTA chelates of multiple radionuclides for pretargeted radioimmunotherapy and imaging

    Energy Technology Data Exchange (ETDEWEB)

    Orcutt, Kelly Davis; Slusarczyk, Adrian L. [Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Cieslewicz, Maryelise [Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Ruiz-Yi, Benjamin [Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Bhushan, Kumar R. [Division of Hematology/Oncology, Beth Israel Deaconess Medical Center, Boston, MA 02215 (United States); Frangioni, John V. [Division of Hematology/Oncology, Beth Israel Deaconess Medical Center, Boston, MA 02215 (United States); Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA 02215 (United States); Wittrup, K. Dane, E-mail: wittrup@mit.ed [Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)

    2011-02-15

    Introduction: In pretargeted radioimmunotherapy (PRIT), a bifunctional antibody is administered and allowed to pre-localize to tumor cells. Subsequently, a chelated radionuclide is administered and captured by cell-bound antibody while unbound hapten clears rapidly from the body. We aim to engineer high-affinity binders to 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) chelates for use in PRIT applications. Methods: We mathematically modeled antibody and hapten pharmacokinetics to analyze hapten tumor retention as a function of hapten binding affinity. Motivated by model predictions, we used directed evolution and yeast surface display to affinity mature the 2D12.5 antibody to DOTA, reformatted as a single chain variable fragment (scFv). Results: Modeling predicts that for high antigen density and saturating bsAb dose, a hapten-binding affinity of 100 pM is needed for near-maximal hapten retention. We affinity matured 2D12.5 with an initial binding constant of about 10 nM to DOTA-yttrium chelates. Affinity maturation resulted in a 1000-fold affinity improvement to biotinylated DOTA-yttrium, yielding an 8.2{+-}1.9 picomolar binder. The high-affinity scFv binds DOTA complexes of lutetium and gadolinium with similar picomolar affinity and indium chelates with low nanomolar affinity. When engineered into a bispecific antibody construct targeting carcinoembryonic antigen, pretargeted high-affinity scFv results in significantly higher tumor retention of a {sup 111}In-DOTA hapten compared to pretargeted wild-type scFv in a xenograft mouse model. Conclusions: We have engineered a versatile, high-affinity, DOTA-chelate-binding scFv. We anticipate it will prove useful in developing pretargeted imaging and therapy protocols to exploit the potential of a variety of radiometals.

  9. Sensitivity of MRI in detecting alveolar infiltrates. Experimental studies; Sensitivitaet der MRT fuer alveolaere Infiltrate. Experimentelle Untersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Biederer, J.; Busse, I.; Grimm, J.; Reuter, M.; Heller, M. [Kiel Univ. (Germany). Klinikum fuer Diagnostische Radiologie; Muhle, C. [Kiel Univ. (Germany). Klinik fuer Nuklearmedizin; Freitag, S. [Kiel Univ. (Germany). Inst. fuer Medizinische Informatik und Statistik

    2002-08-01

    Purpose: An experimental study using porcine lung explants and a dedicated chest phantom to evaluate the signal intensity of artificial alveolar infiltrates with T{sub 1}- and T{sub 2}-weighted MRI sequences. Material and Methods: 10 porcine lung explants were intubated, transferred into the cavity of a MRI-compatible chest phantom and inflated by continuous evacuation of the artificial pleural space. All lungs were examined with MRI at 1.5 T before and after intra-tracheal instillation of either 100 or 200 ml gelatine-stabilised liquid to simulate alveolar infiltrates. MR-examination comprised gradient echo (2D- and 3D-GRE) and fast spin echo sequences (T{sub 2}-TSE and T{sub 2}-HASTE). The signal intensity of lung parenchyma was evaluated at representative cross sections using a standardised scheme. Control studies were acquired with helical CT. Results: The instilled liquid caused patchy confluent alveolar infiltrates resembling the findings in patients with pneumonia or ARDS. CT revealed typical ground-glass opacities. Before the application of the liquid, only T{sub 2}-HASTE and T{sub 2}-TSE displayed lung parenchyma signals with a signal/noise ratio of 3.62 and 1.39, respectively. After application of the liquid, both T{sub 2}-weighted sequences showed clearly visible infiltrates with an increase in signal intensity of approx. 30% at 100 ml (p<0.01) and 60% at 200 ml (p<0.01). With 2D- and 3D-GRE the infiltrates were not visible, although the lung parenchyma signal increase was statistically significant. On 2D-GRE the increase in signal intensity reached 0.74% (p=0.32) after 100 ml and 5.6% (p<0.01) after 200 ml for 3D-GRE: 2.2% [p=0.02] at 100 ml and 4.4% at 200 ml [p<0.001]. The CT controls revealed a significant increase of lung density of 17. H.E. at 100 ml (p=0.02) and 75 H.E. at 200 ml (p<0.01). Conclusions: MRI with T{sub 2}-weighted sequences detects artificial alveolar infiltrates with high signal intensity and may be a highly sensitive tool to

  10. Heart MRI

    Science.gov (United States)

    Magnetic resonance imaging - cardiac; Magnetic resonance imaging - heart; Nuclear magnetic resonance - cardiac; NMR - cardiac; MRI of the heart; Cardiomyopathy - MRI; Heart failure - MRI; Congenital heart disease - MRI

  11. Functional MRI of Handwriting Tasks: A Study of Healthy Young Adults Interacting with a Novel Touch-Sensitive Tablet.

    Science.gov (United States)

    Karimpoor, Mahta; Churchill, Nathan W; Tam, Fred; Fischer, Corinne E; Schweizer, Tom A; Graham, Simon J

    2018-01-01

    Handwriting is a complex human activity that engages a blend of cognitive and visual motor skills. Current understanding of the neural correlates of handwriting has largely come from lesion studies of patients with impaired handwriting. Task-based fMRI studies would be useful to supplement this work. To address concerns over ecological validity, previously we developed a fMRI-compatible, computerized tablet system for writing and drawing including visual feedback of hand position and an augmented reality display. The purpose of the present work is to use the tablet system in proof-of-concept to characterize brain activity associated with clinically relevant handwriting tasks, originally developed to characterize handwriting impairments in Alzheimer's disease patients. As a prelude to undertaking fMRI studies of patients, imaging was performed of twelve young healthy subjects who copied sentences, phone numbers, and grocery lists using the fMRI-compatible tablet. Activation maps for all handwriting tasks consisted of a distributed network of regions in reasonable agreement with previous studies of handwriting performance. In addition, differences in brain activity were observed between the test subcomponents consistent with different demands of neural processing for successful task performance, as identified by investigating three quantitative behavioral metrics (writing speed, stylus contact force and stylus in air time). This study provides baseline behavioral and brain activity results for fMRI studies that adopt this handwriting test to characterize patients with brain impairments.

  12. Functional MRI of Handwriting Tasks: A Study of Healthy Young Adults Interacting with a Novel Touch-Sensitive Tablet

    Directory of Open Access Journals (Sweden)

    Mahta Karimpoor

    2018-02-01

    Full Text Available Handwriting is a complex human activity that engages a blend of cognitive and visual motor skills. Current understanding of the neural correlates of handwriting has largely come from lesion studies of patients with impaired handwriting. Task-based fMRI studies would be useful to supplement this work. To address concerns over ecological validity, previously we developed a fMRI-compatible, computerized tablet system for writing and drawing including visual feedback of hand position and an augmented reality display. The purpose of the present work is to use the tablet system in proof-of-concept to characterize brain activity associated with clinically relevant handwriting tasks, originally developed to characterize handwriting impairments in Alzheimer’s disease patients. As a prelude to undertaking fMRI studies of patients, imaging was performed of twelve young healthy subjects who copied sentences, phone numbers, and grocery lists using the fMRI-compatible tablet. Activation maps for all handwriting tasks consisted of a distributed network of regions in reasonable agreement with previous studies of handwriting performance. In addition, differences in brain activity were observed between the test subcomponents consistent with different demands of neural processing for successful task performance, as identified by investigating three quantitative behavioral metrics (writing speed, stylus contact force and stylus in air time. This study provides baseline behavioral and brain activity results for fMRI studies that adopt this handwriting test to characterize patients with brain impairments.

  13. Functional MRI of Handwriting Tasks: A Study of Healthy Young Adults Interacting with a Novel Touch-Sensitive Tablet

    Science.gov (United States)

    Karimpoor, Mahta; Churchill, Nathan W.; Tam, Fred; Fischer, Corinne E.; Schweizer, Tom A.; Graham, Simon J.

    2018-01-01

    Handwriting is a complex human activity that engages a blend of cognitive and visual motor skills. Current understanding of the neural correlates of handwriting has largely come from lesion studies of patients with impaired handwriting. Task-based fMRI studies would be useful to supplement this work. To address concerns over ecological validity, previously we developed a fMRI-compatible, computerized tablet system for writing and drawing including visual feedback of hand position and an augmented reality display. The purpose of the present work is to use the tablet system in proof-of-concept to characterize brain activity associated with clinically relevant handwriting tasks, originally developed to characterize handwriting impairments in Alzheimer’s disease patients. As a prelude to undertaking fMRI studies of patients, imaging was performed of twelve young healthy subjects who copied sentences, phone numbers, and grocery lists using the fMRI-compatible tablet. Activation maps for all handwriting tasks consisted of a distributed network of regions in reasonable agreement with previous studies of handwriting performance. In addition, differences in brain activity were observed between the test subcomponents consistent with different demands of neural processing for successful task performance, as identified by investigating three quantitative behavioral metrics (writing speed, stylus contact force and stylus in air time). This study provides baseline behavioral and brain activity results for fMRI studies that adopt this handwriting test to characterize patients with brain impairments. PMID:29487511

  14. Clinical evaluation of pulmonary perfusion MRI using FAIR (flow-sensitive alternating inversion recovery)-HASTE (Half-Fourier Single-Shot TurboSE) method

    International Nuclear Information System (INIS)

    Togami, Izumi; Sasai, Nobuya; Tsunoda, Masatoshi; Sei, Tetsurou; Sato, Shuhei; Yabuki, Takayuki; Hiraki, Yoshio

    2002-01-01

    The FAIR-HASTE method is a kind of noninvasive perfusion MR imaging obtained without the use of contrast media. By subtracting a flow-insensitive image from a flow-sensitive image, contrast enhancement of inflowing blood achieved. In the present study, we applied pulmonary perfusion FAIR-HASTE sequence for 23 patients with various pulmonary diseases, and compared the findings with those by pulmonary perfusion scintigraphy and Gadolinium perfusion MRI. Pulmonary perfusion imaging with the FAIR-HASTE method was possible in all clinical cases, and the findings corresponded well to those obtained by perfusion MRI using contrast media or pulmonary scintigraphy. The FAIR-HASTE method is a promising method for the evaluation of pulmonary perfusion. (author)

  15. Chemical exchange-sensitive spin-lock MRI of glucose analog 3-O-methyl-d-glucose in normal and ischemic brain.

    Science.gov (United States)

    Jin, Tao; Mehrens, Hunter; Wang, Ping; Kim, Seong-Gi

    2018-05-01

    Glucose transport is important for understanding brain glucose metabolism. We studied glucose transport with a presumably non-toxic and non-metabolizable glucose analog, 3-O-methyl-d-glucose, using a chemical exchange-sensitive spin-lock MRI technique at 9.4 Tesla. 3-O-methyl-d-glucose showed comparable chemical exchange properties with d-glucose and 2-deoxy-d-glucose in phantoms, and higher and lower chemical exchange-sensitive spin-lock sensitivity than Glc and 2-deoxy-d-glucose in in vivo experiments, respectively. The changes of the spin-lattice relaxation rate in the rotating frame (Δ R 1 ρ) in normal rat brain peaked at ∼15 min after the intravenous injection of 1 g/kg 3-O-methyl-d-glucose and almost maintained a plateau for >1 h. Doses up to 4 g/kg 3-O-methyl-d-glucose were linearly correlated with Δ R 1 ρ. In rats with focal ischemic stroke, chemical exchange-sensitive spin-lock with 3-O-methyl-d-glucose injection at 1 h after stroke onset showed reduced Δ R 1 ρ in the ischemic core but higher Δ R 1 ρ in the peri-core region compared to normal tissue, which progressed into the ischemic core at 3 h after stroke onset. This suggests that the hyper-chemical exchange-sensitive spin-lock region observed at 1 h is the ischemic penumbra at-risk of infarct. In summary, 3-O-methyl-d-glucose-chemical exchange-sensitive spin-lock can be a sensitive MRI technique to probe the glucose transport in normal and ischemic brains.

  16. Chemical-exchange-sensitive MRI of amide, amine and NOE at 9.4 T versus 15.2 T.

    Science.gov (United States)

    Chung, Julius Juhyun; Choi, Wonmin; Jin, Tao; Lee, Jung Hee; Kim, Seong-Gi

    2017-09-01

    Chemical exchange (CE)-sensitive MRI benefits greatly from stronger magnetic fields; however, field effects on CE-sensitive imaging have not yet been studied well in vivo. We have compared CE-sensitive Z-spectra and maps obtained at the fields of 9.4 T and 15.2 T in phantoms and rats with off-resonance chemical-exchange-sensitive spin lock (CESL), which is similar to conventional chemical exchange saturation transfer. At higher fields, the background peak at water resonance has less spread and the exchange rate relative to chemical shift decreases, thus CESL intensity is dependent on B 0 . For the in vivo amide and nuclear Overhauser enhancement (NOE) composite resonances of rat brains, intensities were similar for both magnetic fields, but effective amide proton transfer and NOE values obtained with three-point quantification or a curve fitting method were larger at 15.2 T due to the reduced spread of attenuation at the direct water resonance. When using intermediate exchange-sensitive irradiation parameters, the amine proton signal was 65% higher at 15.2 T than at 9.4 T due to a reduced ratio of exchange rate to chemical shift. In summary, increasing magnetic field provides enhancements to CE-sensitive signals in the intermediate exchange regime and reduces contamination from background signals in the slow exchange regime. Consequently, ultrahigh magnetic field is advantageous for CE-sensitive MRI, especially for amine and hydroxyl protons. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Prospective trial evaluating the sensitivity and specificity of 3,4-dihydroxy-6-[18F]-fluoro-L-phenylalanine (18F-DOPA) PET and MRI in patients with recurrent gliomas.

    Science.gov (United States)

    Youland, Ryan S; Pafundi, Deanna H; Brinkmann, Debra H; Lowe, Val J; Morris, Jonathan M; Kemp, Bradley J; Hunt, Christopher H; Giannini, Caterina; Parney, Ian F; Laack, Nadia N

    2018-05-01

    Treatment-related changes can be difficult to differentiate from progressive glioma using MRI with contrast (CE). The purpose of this study is to compare the sensitivity and specificity of 18F-DOPA-PET and MRI in patients with recurrent glioma. Thirteen patients with MRI findings suspicious for recurrent glioma were prospectively enrolled and underwent 18F-DOPA-PET and MRI for neurosurgical planning. Stereotactic biopsies were obtained from regions of concordant and discordant PET and MRI CE, all within regions of T2/FLAIR signal hyperintensity. The sensitivity and specificity of 18F-DOPA-PET and CE were calculated based on histopathologic analysis. Receiver operating characteristic curve analysis revealed optimal tumor to normal (T/N) and SUVmax thresholds. In the 37 specimens obtained, 51% exhibited MRI contrast enhancement (M+) and 78% demonstrated 18F-DOPA-PET avidity (P+). Imaging characteristics included M-P- in 16%, M-P+ in 32%, M+P+ in 46% and M+P- in 5%. Histopathologic review of biopsies revealed grade II components in 16%, grade III in 43%, grade IV in 30% and no tumor in 11%. MRI CE sensitivity for recurrent tumor was 52% and specificity was 50%. PET sensitivity for tumor was 82% and specificity was 50%. A T/N threshold > 2.0 altered sensitivity to 76% and specificity to 100% and SUVmax > 1.36 improved sensitivity and specificity to 94 and 75%, respectively. 18F-DOPA-PET can provide increased sensitivity and specificity compared with MRI CE for visualizing the spatial distribution of recurrent gliomas. Future studies will incorporate 18F-DOPA-PET into re-irradiation target volume delineation for RT planning.

  18. Diagnostic evaluation of a nanobody with picomolar affinity toward the protease RgpB from Porphyromonas gingivalis.

    Science.gov (United States)

    Skottrup, Peter Durand; Leonard, Paul; Kaczmarek, Jakub Zbigniew; Veillard, Florian; Enghild, Jan Johannes; O'Kennedy, Richard; Sroka, Aneta; Clausen, Rasmus Prætorius; Potempa, Jan; Riise, Erik

    2011-08-15

    Porphyromonas gingivalis is one of the major periodontitis-causing pathogens. P. gingivalis secretes a group of proteases termed gingipains, and in this study we have used the RgpB gingipain as a biomarker for P. gingivalis. We constructed a naive camel nanobody library and used phage display to select one nanobody toward RgpB with picomolar affinity. The nanobody was used in an inhibition assay for detection of RgpB in buffer as well as in saliva. The nanobody was highly specific for RgpB given that it did not bind to the homologous gingipain HRgpA. This indicated the presence of a binding epitope within the immunoglobulin-like domain of RgpB. A subtractive inhibition assay was used to demonstrate that the nanobody could bind native RgpB in the context of intact cells. The nanobody bound exclusively to the P. gingivalis membrane-bound RgpB isoform (mt-RgpB) and to secreted soluble RgpB. Further cross-reactivity studies with P. gingivalis gingipain deletion mutants showed that the nanobody could discriminate between native RgpB and native Kgp and RgpA in complex bacterial samples. This study demonstrates that RgpB can be used as a specific biomarker for P. gingivalis detection and that the presented nanobody-based assay could supplement existing methods for P. gingivalis detection. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Bivalent Llama Single-Domain Antibody Fragments against Tumor Necrosis Factor Have Picomolar Potencies due to Intramolecular Interactions

    Directory of Open Access Journals (Sweden)

    Els Beirnaert

    2017-07-01

    Full Text Available The activity of tumor necrosis factor (TNF, a cytokine involved in inflammatory pathologies, can be inhibited by antibodies or trap molecules. Herein, llama-derived variable heavy-chain domains of heavy-chain antibody (VHH, also called Nanobodies™ were generated for the engineering of bivalent constructs, which antagonize the binding of TNF to its receptors with picomolar potencies. Three monomeric VHHs (VHH#1, VHH#2, and VHH#3 were characterized in detail and found to bind TNF with sub-nanomolar affinities. The crystal structures of the TNF–VHH complexes demonstrate that VHH#1 and VHH#2 share the same epitope, at the center of the interaction area of TNF with its TNFRs, while VHH#3 binds to a different, but partially overlapping epitope. These structures rationalize our results obtained with bivalent constructs in which two VHHs were coupled via linkers of different lengths. Contrary to conventional antibodies, these bivalent Nanobody™ constructs can bind to a single trimeric TNF, thus binding with avidity and blocking two of the three receptor binding sites in the cytokine. The different mode of binding to antigen and the engineering into bivalent constructs supports the design of highly potent VHH-based therapeutic entities.

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging ... over time. top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging ...

  1. Water and fat separation in real-time MRI of joint movement with phase-sensitive bSSFP.

    Science.gov (United States)

    Mazzoli, Valentina; Nederveen, Aart J; Oudeman, Jos; Sprengers, Andre; Nicolay, Klaas; Strijkers, Gustav J; Verdonschot, Nico

    2017-07-01

    To introduce a method for obtaining fat-suppressed images in real-time MRI of moving joints at 3 Tesla (T) using a bSSFP sequence with phase detection to enhance visualization of soft tissue structures during motion. The wrist and knee of nine volunteers were imaged with a real-time bSSFP sequence while performing dynamic tasks. For appropriate choice of sequence timing parameters, water and fat pixels showed an out-of-phase behavior, which was exploited to reconstruct water and fat images. Additionally, a 2-point Dixon sequence was used for dynamic imaging of the joints, and resulting water and fat images were compared with our proposed method. The joints could be visualized with good water-fat separation and signal-to-noise ratio (SNR), while maintaining a relatively high temporal resolution (5 fps in knee imaging and 10 fps in wrist imaging). The proposed method produced images of moving joints with higher SNR and higher image quality when compared with the Dixon method. Water-fat separation is feasible in real-time MRI of moving knee and wrist at 3 T. PS-bSSFP offers movies with higher SNR and higher diagnostic quality when compared with Dixon scans. Magn Reson Med 78:58-68, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  2. Determination of picomolar beryllium levels in seawater with inductively coupled plasma mass spectrometry following silica-gel preconcentration

    Energy Technology Data Exchange (ETDEWEB)

    Tazoe, Hirofumi, E-mail: tazoe@cc.hirosaki-u.ac.jp [Department of Radiation Chemistry, Institute of Radiation Emergency Mediation, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori 036-8564 (Japan); College of Humanities and Sciences, Nihon University, 3-25-40, Sakurajosui, Setagaya-ku, Tokyo 156-8550 (Japan); Yamagata, Takeyasu [College of Humanities and Sciences, Nihon University, 3-25-40, Sakurajosui, Setagaya-ku, Tokyo 156-8550 (Japan); Obata, Hajime [Atmosphere and Ocean Research Institute, The Tokyo University, 5-1-5 Kashiwanoha, Kashiwa-shi, Chiba 277-8564 (Japan); Nagai, Hisao [College of Humanities and Sciences, Nihon University, 3-25-40, Sakurajosui, Setagaya-ku, Tokyo 156-8550 (Japan)

    2014-12-10

    Highlights: • We developesd the simplest and robust SPE method for ultra low picomolar level beryllium in seawater. • Just silica gel column can quantitatively adsorb beryllium in neutral pH condition containing natural seawater. • EDTA solution can eliminate seawater matrixes retaining Be in the column, which optimize to ICP-MS detemination. • Accurate and precise Be data have been obtained for natural seawater from North Pacific Ocean. - Abstract: A robust and rapid method for the determination of natural levels of beryllium (Be) in seawater was developed to facilitate mapping Be concentrations in the ocean. A solid-phase extraction method using a silica gel column was applied for preconcentration and purification of Be in seawater prior to determination of Be concentrations with inductively coupled plasma mass spectrometry (ICP-MS). Be was quantitatively adsorbed onto silica gel from solutions with pH values ranging from 6.3 to 9, including natural seawater. The chelating agent ethylenediamine tetraacetic acid was used to remove other ions in the seawater matrix (Na, Mg, and Ca) that interfere with the ICP-MS analysis. The reproducibility of the method was 3% based on triplicate analyses of natural seawater samples, and the detection limit was 0.4 pmol kg{sup −1} for 250 mL of seawater, which is sufficient for the analysis of seawater in the open ocean. The method was then used to determine the vertical profile of Be in the eastern North Pacific Ocean, which was found to be a recycled-type profile in which the Be concentration increased with depth from the surface (7.2 pmol kg{sup −1} at <200 m) to deep water (29.2 pmol kg{sup −1} from 3500 m to the bottom)

  3. Determination of picomolar beryllium levels in seawater with inductively coupled plasma mass spectrometry following silica-gel preconcentration

    International Nuclear Information System (INIS)

    Tazoe, Hirofumi; Yamagata, Takeyasu; Obata, Hajime; Nagai, Hisao

    2014-01-01

    Highlights: • We developesd the simplest and robust SPE method for ultra low picomolar level beryllium in seawater. • Just silica gel column can quantitatively adsorb beryllium in neutral pH condition containing natural seawater. • EDTA solution can eliminate seawater matrixes retaining Be in the column, which optimize to ICP-MS detemination. • Accurate and precise Be data have been obtained for natural seawater from North Pacific Ocean. - Abstract: A robust and rapid method for the determination of natural levels of beryllium (Be) in seawater was developed to facilitate mapping Be concentrations in the ocean. A solid-phase extraction method using a silica gel column was applied for preconcentration and purification of Be in seawater prior to determination of Be concentrations with inductively coupled plasma mass spectrometry (ICP-MS). Be was quantitatively adsorbed onto silica gel from solutions with pH values ranging from 6.3 to 9, including natural seawater. The chelating agent ethylenediamine tetraacetic acid was used to remove other ions in the seawater matrix (Na, Mg, and Ca) that interfere with the ICP-MS analysis. The reproducibility of the method was 3% based on triplicate analyses of natural seawater samples, and the detection limit was 0.4 pmol kg −1 for 250 mL of seawater, which is sufficient for the analysis of seawater in the open ocean. The method was then used to determine the vertical profile of Be in the eastern North Pacific Ocean, which was found to be a recycled-type profile in which the Be concentration increased with depth from the surface (7.2 pmol kg −1 at <200 m) to deep water (29.2 pmol kg −1 from 3500 m to the bottom)

  4. Quantifying the microvascular origin of BOLD-fMRI from first principles with two-photon microscopy and an oxygen-sensitive nanoprobe.

    Science.gov (United States)

    Gagnon, Louis; Sakadžić, Sava; Lesage, Frédéric; Musacchia, Joseph J; Lefebvre, Joël; Fang, Qianqian; Yücel, Meryem A; Evans, Karleyton C; Mandeville, Emiri T; Cohen-Adad, Jülien; Polimeni, Jonathan R; Yaseen, Mohammad A; Lo, Eng H; Greve, Douglas N; Buxton, Richard B; Dale, Anders M; Devor, Anna; Boas, David A

    2015-02-25

    The blood oxygenation level-dependent (BOLD) contrast is widely used in functional magnetic resonance imaging (fMRI) studies aimed at investigating neuronal activity. However, the BOLD signal reflects changes in blood volume and oxygenation rather than neuronal activity per se. Therefore, understanding the transformation of microscopic vascular behavior into macroscopic BOLD signals is at the foundation of physiologically informed noninvasive neuroimaging. Here, we use oxygen-sensitive two-photon microscopy to measure the BOLD-relevant microvascular physiology occurring within a typical rodent fMRI voxel and predict the BOLD signal from first principles using those measurements. The predictive power of the approach is illustrated by quantifying variations in the BOLD signal induced by the morphological folding of the human cortex. This framework is then used to quantify the contribution of individual vascular compartments and other factors to the BOLD signal for different magnet strengths and pulse sequences. Copyright © 2015 the authors 0270-6474/15/353663-13$15.00/0.

  5. Zinc-sensitive MRI contrast agent detects differential release of Zn(II) ions from the healthy vs. malignant mouse prostate.

    Science.gov (United States)

    Clavijo Jordan, M Veronica; Lo, Su-Tang; Chen, Shiuhwei; Preihs, Christian; Chirayil, Sara; Zhang, Shanrong; Kapur, Payal; Li, Wen-Hong; De Leon-Rodriguez, Luis M; Lubag, Angelo J M; Rofsky, Neil M; Sherry, A Dean

    2016-09-13

    Many secretory tissues release Zn(II) ions along with other molecules in response to external stimuli. Here we demonstrate that secretion of Zn(II) ions from normal, healthy prostate tissue is stimulated by glucose in fasted mice and that release of Zn(II) can be monitored by MRI. An ∼50% increase in water proton signal enhancement is observed in T1-weighted images of the healthy mouse prostate after infusion of a Gd-based Zn(II) sensor and an i.p. bolus of glucose. Release of Zn(II) from intracellular stores was validated in human epithelial prostate cells in vitro and in surgically exposed prostate tissue in vivo using a Zn(II)-sensitive fluorescent probe known to bind to the extracellular surface of cells. Given the known differences in intracellular Zn(II) stores in healthy versus malignant prostate tissues, the Zn(II) sensor was then evaluated in a transgenic adenocarcinoma of the mouse prostate (TRAMP) model in vivo. The agent proved successful in detecting small malignant lesions as early as 11 wk of age, making this noninvasive MR imaging method potentially useful for identifying prostate cancer in situations where it may be difficult to detect using current multiparametric MRI protocols.

  6. A neutral polydisulfide containing Gd(III) DOTA monoamide as a redox-sensitive biodegradable macromolecular MRI contrast agent.

    Science.gov (United States)

    Ye, Zhen; Zhou, Zhuxian; Ayat, Nadia; Wu, Xueming; Jin, Erlei; Shi, Xiaoyue; Lu, Zheng-Rong

    2016-01-01

    This work aims to develop safe and effective gadolinium (III)-based biodegradable macromolecular MRI contrast agents for blood pool and cancer imaging. A neutral polydisulfide containing macrocyclic Gd-DOTA monoamide (GOLS) was synthesized and characterized. In addition to studying the in vitro degradation of GOLS, its kinetic stability was also investigated in an in vivo model. The efficacy of GOLS for contrast-enhanced MRI was examined with female BALB/c mice bearing 4T1 breast cancer xenografts. The pharmacokinetics, biodistribution, and metabolism of GOLS were also determined in mice. GOLS has an apparent molecular weight of 23.0 kDa with T1 relaxivities of 7.20 mM(-1) s(-1) per Gd at 1.5 T, and 6.62 mM(-1) s(-1) at 7.0 T. GOLS had high kinetic inertness against transmetallation with Zn(2+) ions, and its polymer backbone was readily cleaved by L-cysteine. The agent showed improved efficacy for blood pool and tumor MR imaging. The structural effect on biodistribution and in vivo chelation stability was assessed by comparing GOLS with Gd(HP-DO3A), a negatively charged polydisulfide containing Gd-DOTA monoamide GODC, and a polydisulfide containing Gd-DTPA-bisamide (GDCC). GOLS showed high in vivo chelation stability and minimal tissue deposition of gadolinium. The biodegradable macromolecular contrast agent GOLS is a promising polymeric contrast agent for clinical MR cardiovascular imaging and cancer imaging. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Versatile action of picomolar gradients of progesterone on different sperm subpopulations.

    Directory of Open Access Journals (Sweden)

    Diego Rafael Uñates

    Full Text Available High step concentrations of progesterone may stimulate various sperm physiological processes, such as priming and the acrosome reaction. However, approaching the egg, spermatozoa face increasing concentrations of the hormone, as it is secreted by the cumulus cells and then passively diffuses along the cumulus matrix and beyond. In this context, several questions arise: are spermatozoa sensitive to the steroid gradients as they undergo priming and the acrosome reaction? If so, what are the functional gradual concentrations of progesterone? Do spermatozoa in different physiological states respond differentially to steroid gradients? To answer these questions, spermatozoa were confronted with progesterone gradients generated by different hormone concentrations (1 pM to 100 µM. Brief exposure to a 10 pM progesterone gradient stimulated priming for the acrosome reaction in one sperm subpopulation, and simultaneously induced the acrosome reaction in a different sperm subpopulation. This effect was not observed in non-capacitated cells or when progesterone was homogeneously distributed. The results suggest a versatile role of the gradual distribution of very low doses of progesterone, which selectively stimulate the priming and the acrosome reaction in different sperm subpopulations.

  8. Quantitative and Visual Assessments toward Potential Sub-mSv or Ultrafast FDG PET Using High-Sensitivity TOF PET in PET/MRI.

    Science.gov (United States)

    Behr, Spencer C; Bahroos, Emma; Hawkins, Randall A; Nardo, Lorenzo; Ravanfar, Vahid; Capbarat, Emily V; Seo, Youngho

    2018-06-01

    Newer high-performance time-of-flight (TOF) positron emission tomography (PET) systems have the capability to preserve diagnostic image quality with low count density, while maintaining a high raw photon detection sensitivity that would allow for a reduction in injected dose or rapid data acquisition. To assess this, we performed quantitative and visual assessments of the PET images acquired using a highly sensitive (23.3 cps/kBq) large field of view (25-cm axial) silicon photomultiplier (SiPM)-based TOF PET (400-ps timing resolution) integrated with 3 T-MRI in comparison to PET images acquired on non-TOF PET/x-ray computed tomography (CT) systems. Whole-body 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) PET/CT was acquired for 15 patients followed by whole body PET/magnetic resonance imaging (MRI) with an average injected dose of 325 ± 84 MBq. The PET list mode data from PET/MRI were reconstructed using full datasets (4 min/bed) and reduced datasets (2, 1, 0.5, and 0.25 min/bed). Qualitative assessment between PET/CT and PET/MR images were made. A Likert-type scale between 1 and 5, 1 for non-diagnostic, 3 equivalent to PET/CT, and 5 superior quality, was used. Maximum and mean standardized uptake values (SUV max and SUV mean ) of normal tissues and lesions detected were measured and compared. Mean visual assessment scores were 3.54 ± 0.32, 3.62 ± 0.38, and 3.69 ± 0.35 for the brain and 3.05 ± 0.49, 3.71 ± 0.45, and 4.14 ± 0.44 for the whole-body maximum intensity projections (MIPs) for 1, 2, and 4 min/bed PET/MR images, respectively. The SUV mean values for normal tissues were lower and statistically significant for images acquired at 4, 2, 1, 0.5, and 0.25 min/bed on the PET/MR, with values of - 18 ± 28 % (p PET/MR datasets. High-sensitivity TOF PET showed comparable but still better visual image quality even at a much reduced activity in comparison to lower-sensitivity non-TOF PET. Our data translates to a seven times

  9. Improving the use of principal component analysis to reduce physiological noise and motion artifacts to increase the sensitivity of task-based fMRI.

    Science.gov (United States)

    Soltysik, David A; Thomasson, David; Rajan, Sunder; Biassou, Nadia

    2015-02-15

    Functional magnetic resonance imaging (fMRI) time series are subject to corruption by many noise sources, especially physiological noise and motion. Researchers have developed many methods to reduce physiological noise, including RETROICOR, which retroactively removes cardiac and respiratory waveforms collected during the scan, and CompCor, which applies principal components analysis (PCA) to remove physiological noise components without any physiological monitoring during the scan. We developed four variants of the CompCor method. The optimized CompCor method applies PCA to time series in a noise mask, but orthogonalizes each component to the BOLD response waveform and uses an algorithm to determine a favorable number of components to use as "nuisance regressors." Whole brain component correction (WCompCor) is similar, except that it applies PCA to time-series throughout the whole brain. Low-pass component correction (LCompCor) identifies low-pass filtered components throughout the brain, while high-pass component correction (HCompCor) identifies high-pass filtered components. We compared the new methods with the original CompCor method by examining the resulting functional contrast-to-noise ratio (CNR), sensitivity, and specificity. (1) The optimized CompCor method increased the CNR and sensitivity compared to the original CompCor method and (2) the application of WCompCor yielded the best improvement in the CNR and sensitivity. The sensitivity of the optimized CompCor, WCompCor, and LCompCor methods exceeded that of the original CompCor method. However, regressing noise signals showed a paradoxical consequence of reducing specificity for all noise reduction methods attempted. Published by Elsevier B.V.

  10. Characterization of image heterogeneity using 2D Minkowski functionals increases the sensitivity of detection of a targeted MRI contrast agent.

    Science.gov (United States)

    Canuto, Holly C; McLachlan, Charles; Kettunen, Mikko I; Velic, Marko; Krishnan, Anant S; Neves, Andre' A; de Backer, Maaike; Hu, D-E; Hobson, Michael P; Brindle, Kevin M

    2009-05-01

    A targeted Gd(3+)-based contrast agent has been developed that detects tumor cell death by binding to the phosphatidylserine (PS) exposed on the plasma membrane of dying cells. Although this agent has been used to detect tumor cell death in vivo, the differences in signal intensity between treated and untreated tumors was relatively small. As cell death is often spatially heterogeneous within tumors, we investigated whether an image analysis technique that parameterizes heterogeneity could be used to increase the sensitivity of detection of this targeted contrast agent. Two-dimensional (2D) Minkowski functionals (MFs) provided an automated and reliable method for parameterization of image heterogeneity, which does not require prior assumptions about the number of regions or features in the image, and were shown to increase the sensitivity of detection of the contrast agent as compared to simple signal intensity analysis. (c) 2009 Wiley-Liss, Inc.

  11. Enhancement pattern of small hepatocellular carcinoma (HCC) at contrast-enhanced US (CEUS), MDCT, and MRI: Intermodality agreement and comparison of diagnostic sensitivity between 2005 and 2010 American Association for the Study of Liver Diseases (AASLD) guidelines

    International Nuclear Information System (INIS)

    Furlan, Alessandro; Marin, Daniele; Cabassa, Paolo; Taibbi, Adele; Brunelli, Elena; Agnello, Francesco; Lagalla, Roberto; Brancatelli, Giuseppe

    2012-01-01

    Objective: To evaluate agreement between contrast-enhanced ultrasound (CEUS), multi-detector row computed tomography (MDCT) and magnetic resonance imaging (MRI) for the assessment of typical and atypical enhancement patterns of small hepatocellular carcinoma (HCC); and to compare diagnostic sensitivity of 2005 and 2010 American Association for the Study of Liver Diseases (AASLD) guidelines. Materials and methods: Between January 2008 and December 2009, we included cirrhotic patients with newly diagnosed 10–20 mm HCC imaged at two contrast-enhanced imaging techniques among CEUS, MDCT, and MRI. Dynamic studies were reviewed by two radiologists to assess enhancement pattern. Percentage of cases with concordant findings and Cohen coefficient (k) were calculated. McNemar's test was used to compare sensitivity between 2005 and 2010 AASLD guidelines. Results: There were 91 patients (69 M; 22 F; mean age, 68 years) with 96 HCCs, studied with a combination of CEUS and MDCT (n = 59), CEUS and MRI (n = 26), or MDCT and MRI (n = 11). Intermodality agreement for assessment of tumor enhancement pattern was 67% (k = 0.294, P = 0.001). Typical enhancement pattern was detected coincidentally at two imaging modalities in 50 (52%) HCCs. Sensitivity for the diagnosis of HCC increased significantly using the 2010 AASLD (81/96 (84%) vs. 50/96 (52%), P < 0.001). Conclusions: Agreement between two imaging modalities for the detection of typical tumor enhancement pattern was reached in 52% of cases. The 2010 AASLD guidelines significantly increased the sensitivity for the diagnosis of HCC

  12. Simultaneous pH-sensitive and oxygen-sensitive MRI of human gliomas at 3 T using multi-echo amine proton chemical exchange saturation transfer spin-and-gradient echo echo-planar imaging (CEST-SAGE-EPI).

    Science.gov (United States)

    Harris, Robert J; Yao, Jingwen; Chakhoyan, Ararat; Raymond, Catalina; Leu, Kevin; Liau, Linda M; Nghiemphu, Phioanh L; Lai, Albert; Salamon, Noriko; Pope, Whitney B; Cloughesy, Timothy F; Ellingson, Benjamin M

    2018-04-06

    To introduce a new pH-sensitive and oxygen-sensitive MRI technique using amine proton CEST echo spin-and-gradient echo (SAGE) EPI (CEST-SAGE-EPI). pH-weighting was obtained using CEST estimations of magnetization transfer ratio asymmetry (MTR asym ) at 3 ppm, and oxygen-weighting was obtained using R2' measurements. Glutamine concentration, pH, and relaxation rates were varied in phantoms to validate simulations and estimate relaxation rates. The values of MTR asym and R2' in normal-appearing white matter, T 2 hyperintensity, contrast enhancement, and macroscopic necrosis were measured in 47 gliomas. Simulation and phantom results confirmed an increase in MTR asym with decreasing pH. The CEST-SAGE-EPI estimates of R 2 , R2*, and R2' varied linearly with gadolinium diethylenetriamine penta-acetic acid concentration (R 2  = 6.2 mM -1 ·sec -1 and R2* = 6.9 mM -1 ·sec -1 ). The CEST-SAGE-EPI and Carr-Purcell-Meiboom-Gill estimates of R 2 (R 2  = 0.9943) and multi-echo gradient-echo estimates of R2* (R 2  = 0.9727) were highly correlated. T 2 lesions had lower R2' and higher MTR asym compared with normal-appearing white matter, suggesting lower hypoxia and high acidity, whereas contrast-enhancement tumor regions had elevated R2' and MTR asym , indicating high hypoxia and acidity. The CEST-SAGE-EPI technique provides simultaneous pH-sensitive and oxygen-sensitive image contrasts for evaluation of the brain tumor microenvironment. Advantages include fast whole-brain acquisition, in-line B 0 correction, and simultaneous estimation of CEST effects, R 2 , R2*, and R2' at 3 T. © 2018 International Society for Magnetic Resonance in Medicine.

  13. Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRI.

    Science.gov (United States)

    Hirtler, Daniel; Garcia, Julio; Barker, Alex J; Geiger, Julia

    2016-10-01

    To comprehensively and quantitatively analyse flow and vorticity in the right heart of patients after repair of tetralogy of Fallot (rTOF) compared with healthy volunteers. Time-resolved flow-sensitive 4D MRI was acquired in 24 rTOF patients and 12 volunteers. Qualitative flow evaluation was based on consensus reading of two observers. Quantitative analysis included segmentation of the right atrium (RA) and ventricle (RV) in a four-chamber view to extract volumes and regional haemodynamic information for computation of regional mean and peak vorticity. Right heart intra-atrial, intraventricular and outflow tract flow patterns differed considerably between rTOF patients and volunteers. Peak RA and mean RV vorticity was significantly higher in patients (p = 0.02/0.05). Significant negative correlations were found between patients' maximum and mean RV and RA vorticity and ventricular volumes (p tetralogy of Fallot. • Regurgitant flow in the main pulmonary artery is associated with higher right heart vorticity.

  14. Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hirtler, Daniel [University Hospital Freiburg, Department of Congenital Heart Defects and Pediatric Cardiology (Heart Center, University of Freiburg), Freiburg (Germany); Garcia, Julio; Barker, Alex J. [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Geiger, Julia [University Childrens' Hospital Zurich, Department of Radiology, Zurich (Switzerland)

    2016-10-15

    To comprehensively and quantitatively analyse flow and vorticity in the right heart of patients after repair of tetralogy of Fallot (rTOF) compared with healthy volunteers. Time-resolved flow-sensitive 4D MRI was acquired in 24 rTOF patients and 12 volunteers. Qualitative flow evaluation was based on consensus reading of two observers. Quantitative analysis included segmentation of the right atrium (RA) and ventricle (RV) in a four-chamber view to extract volumes and regional haemodynamic information for computation of regional mean and peak vorticity. Right heart intra-atrial, intraventricular and outflow tract flow patterns differed considerably between rTOF patients and volunteers. Peak RA and mean RV vorticity was significantly higher in patients (p = 0.02/0.05). Significant negative correlations were found between patients' maximum and mean RV and RA vorticity and ventricular volumes (p < 0.05). The main pulmonary artery (MPA) regurgitant flow was associated with higher RA and RV vorticity, which was significant for RA maximum and RV mean vorticity (p = 0.01/0.03). The calculation of vorticity based on 4D flow data is an alternative approach to assess intracardiac flow changes in rTOF patients compared with qualitative flow visualization. Alterations in intracardiac vorticity could be relevant with regard to the development of RV dilation and impaired function. (orig.)

  15. Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRI

    International Nuclear Information System (INIS)

    Hirtler, Daniel; Garcia, Julio; Barker, Alex J.; Geiger, Julia

    2016-01-01

    To comprehensively and quantitatively analyse flow and vorticity in the right heart of patients after repair of tetralogy of Fallot (rTOF) compared with healthy volunteers. Time-resolved flow-sensitive 4D MRI was acquired in 24 rTOF patients and 12 volunteers. Qualitative flow evaluation was based on consensus reading of two observers. Quantitative analysis included segmentation of the right atrium (RA) and ventricle (RV) in a four-chamber view to extract volumes and regional haemodynamic information for computation of regional mean and peak vorticity. Right heart intra-atrial, intraventricular and outflow tract flow patterns differed considerably between rTOF patients and volunteers. Peak RA and mean RV vorticity was significantly higher in patients (p = 0.02/0.05). Significant negative correlations were found between patients' maximum and mean RV and RA vorticity and ventricular volumes (p < 0.05). The main pulmonary artery (MPA) regurgitant flow was associated with higher RA and RV vorticity, which was significant for RA maximum and RV mean vorticity (p = 0.01/0.03). The calculation of vorticity based on 4D flow data is an alternative approach to assess intracardiac flow changes in rTOF patients compared with qualitative flow visualization. Alterations in intracardiac vorticity could be relevant with regard to the development of RV dilation and impaired function. (orig.)

  16. Dynamic contrast enhanced-magnetic resonance imaging (DCE-MRI) for the assessment of Pc 4-sensitized photodynamic therapy of a U87-derived glioma model in the athymic nude rat

    Science.gov (United States)

    Anka, Ali; Thompson, Paul; Mott, Eric; Sharma, Rahul; Zhang, Ruozhen; Cross, Nathan; Sun, Jiayang; Flask, Chris A.; Oleinick, Nancy L.; Dean, David

    2010-02-01

    Introduction: Dynamic Contrast-Enhanced-Magnetic Resonance Imaging (DCE-MRI) may provide a means of tracking the outcome of Pc 4-sensitized photodynamic therapy (PDT) in deeply placed lesions (e.g., brain tumors). We previously determined that 150 μL of gadolinium (Gd-DTPA) produces optimal enhancement of U87-derived intracerebral tumors in an athymic nude rat glioma model. We wish to determine how consistently DCE-MRI enhancement will detect an increase in Gd-enhancement of these tumors following Pc 4-PDT. Methods: We injected 2.5 x 105 U87 cells into the brains of 6 athymic nude rats. After 7-8 days pre-Pc 4 PDT peri-tumor DCE-MRI images were acquired on a 7.0T microMRI scanner before and after administration of 150 μL Gd. DCE-MRI scans were repeated on Days 11, 12, and 13 following Pc 4-PDT (Day 8 or 9). Results: Useful DCE-MRI data were obtained for these animals before and after Pc 4- PDT. In the pre-Pc 4-PDT DCE-MRI scans an average normalized peak Gd enhancement was observed in tumor tissue that was 1.297 times greater than baseline (0.035 Standard Error [SE]). The average normalized peak Gd enhancement in the tumor tissue in the scan following PDT (Day 11) was 1.537 times greater than baseline (0.036 SE), a statistically significant increase in enhancement (p = 0.00584) over the pre-PDT level. Discussion: A 150 μL Gd dose appears to provide an unambiguous increase in signal indicating Pc 4-PDT-induced necrosis of the U87-derived tumor. Our DCEMRI protocol may allow the development of a clinically robust, unambiguous, non-invasive technique for the assessment of PDT outcome.

  17. MRI in head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Kyo [Shin Wha Hospital, Seoul (Korea, Republic of)

    1986-02-15

    In the diagnosis of head injury, Magnetic Resonance Imaging (MRI), like CT, is an effective method of distinguishing between intracerebral and extracerebral lesions. In our experience of MRI, early hematomas are almost isointense by Saturation Recovery (SR) method, so these must be performed with Spin Echo (SE) method for better visualization of hematomas. Isodense subdural hematomas, which is a diagnostic dilemma on CT images, are clearly seen on MRI. Delayed hematomas or residual parenchymal lesions are better demonstrated on MRI than on CT. Direct cornal, sagittal images and multiplanar facility of MRI provides excellent visualization of the the location and shape of extracerebral collection of hematoma. For the screening of head traumas, SE method is a technique of choice because of its excellent sensitivity within limited time.

  18. MRI in head trauma

    International Nuclear Information System (INIS)

    Hong, Jin Kyo

    1986-01-01

    In the diagnosis of head injury, Magnetic Resonance Imaging (MRI), like CT, is an effective method of distinguishing between intracerebral and extracerebral lesions. In our experience of MRI, early hematomas are almost isointense by Saturation Recovery (SR) method, so these must be performed with Spin Echo (SE) method for better visualization of hematomas. Isodense subdural hematomas, which is a diagnostic dilemma on CT images, are clearly seen on MRI. Delayed hematomas or residual parenchymal lesions are better demonstrated on MRI than on CT. Direct cornal, sagittal images and multiplanar facility of MRI provides excellent visualization of the the location and shape of extracerebral collection of hematoma. For the screening of head traumas, SE method is a technique of choice because of its excellent sensitivity within limited time.

  19. Diffusion, confusion and functional MRI

    International Nuclear Information System (INIS)

    Le Bihan, Denis

    2012-01-01

    Diffusion MRI has been introduced in 1985 and has had a very successful life on its own. While it has become a standard for imaging stroke and white matter disorders, the borders between diffusion MRI and the general field of fMRI have always remained fuzzy. First, diffusion MRI has been used to obtain images of brain function, based on the idea that diffusion MRI could also be made sensitive to blood flow, through the intra-voxel incoherent motion (IVIM) concept. Second, the IVIM concept helped better understand the contribution from different vasculature components to the BOLD fMRI signal. Third, it has been shown recently that a genuine fMRI signal can be obtained with diffusion MRI. This 'DfMRI' signal is notably different from the BOLD fMRI signal, especially for its much faster response to brain activation both at onset and offset, which points out to structural changes in the neural tissues, perhaps such as cell swelling, occurring in activated neural tissue. This short article reviews the major steps which have paved the way for this exciting development, underlying how technical progress with MRI equipment has each time been instrumental to expand the horizon of diffusion MRI toward the field of fMRI. (authors)

  20. Chest MRI

    Science.gov (United States)

    ... resonance imaging - chest; NMR - chest; MRI of the thorax; Thoracic MRI Patient Instructions ... Gotway MB, Panse PM, Gruden JF, Elicker BM. Thoracic radiology. In: Broaddus VC, Mason RJ, Ernst JD, et ...

  1. Longitudinal sensitivity to change of MRI-based muscle cross-sectional area versus isometric strength analysis in osteoarthritic knees with and without structural progression: pilot data from the Osteoarthritis Initiative.

    Science.gov (United States)

    Dannhauer, Torben; Sattler, Martina; Wirth, Wolfgang; Hunter, David J; Kwoh, C Kent; Eckstein, Felix

    2014-08-01

    Biomechanical measurement of muscle strength represents established technology in evaluating limb function. Yet, analysis of longitudinal change suffers from relatively large between-measurement variability. Here, we determine the sensitivity to change of magnetic resonance imaging (MRI)-based measurement of thigh muscle anatomical cross sectional areas (ACSAs) versus isometric strength in limbs with and without structural progressive knee osteoarthritis (KOA), with focus on the quadriceps. Of 625 "Osteoarthritis Initiative" participants with radiographic KOA, 20 had MRI cartilage and radiographic joint space width loss in the right knee isometric muscle strength measurement and axial T1-weighted spin-echo acquisitions of the thigh. Muscle ACSAs were determined from manual segmentation at 33% femoral length (distal to proximal). In progressor knees, the reduction in quadriceps ACSA between baseline and 2-year follow-up was -2.8 ± 7.9 % (standardized response mean [SRM] = -0.35), and it was -1.8 ± 6.8% (SRM = -0.26) in matched, non-progressive KOA controls. The decline in extensor strength was more variable than that in ACSAs, both in progressors (-3.9 ± 20%; SRM = -0.20) and in non-progressive controls (-4.5 ± 28%; SRM = -0.16). MRI-based analysis of quadriceps muscles ACSAs appears to be more sensitive to longitudinal change than isometric extensor strength and is suggestive of greater loss in limbs with structurally progressive KOA than in non-progressive controls.

  2. MRI for myocarditis

    International Nuclear Information System (INIS)

    Gutberlet, M.; Luecke, C.; Krieghoff, C.; Hildebrand, L.; Steiner, J.; Adam, J.; Grotthoff, M.; Lehmkuhl, L.; Lurz, P.; Eitel, I.; Thiele, H.

    2013-01-01

    Cardiovascular magnetic resonance imaging (CMRI) has become the primary tool for the non-invasive assessment in patients with suspected myocarditis, especially after exclusion of acute coronary syndrome (ACS) for the differential diagnosis. Various MRI parameters are available which have different accuracies. Volumetric and functional ventricular assessment and the occurrence of pericardial effusion alone demonstrate only a poor sensitivity and specificity. The calculation of the T2-ratio (edema assessment), the early or global relative myocardial enhancement (gRE) and the late gadolinium enhancement (LGE), which represents irreversibly injured myocardium, are more specific parameters. All MRI parameters demonstrate the best accuracy in infarct-like acute myocarditis, whereas in chronic myocarditis sensitivity and specificity are less accurate. Therefore, a multisequential (at least two out of three parameters are positive) approach is recommended. The assessment of the value of newer, more quantitative MRI sequences, such as T1 and T2-mapping is still under investigation. (orig.) [de

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... it may cause some medical devices to malfunction. Most orthopedic implants pose no risk, but you should ... a digital cloud server. Currently, MRI is the most sensitive imaging test of the head (particularly the ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging test ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  6. Cerebral malaria: susceptibility weighted MRI

    Directory of Open Access Journals (Sweden)

    Vinit Baliyan

    2015-03-01

    Full Text Available Cerebral malaria is one of the fatal complications of Plasmodium falciparum infection. Pathogenesis involves cerebral microangiopathy related to microvascular plugging by infected red blood cells. Conventional imaging with MRI and CT do not reveal anything specific in case of cerebral malaria. Susceptibility weighted imaging, a recent advance in the MRI, is very sensitive to microbleeds related to microangiopathy. Histopathological studies in cerebral malaria have revealed microbleeds in brain parenchyma secondary to microangiopathy. Susceptibility weighted imaging, being exquisitely sensitive to microbleeds may provide additional information and improve the diagnostic accuracy of MRI in cerebral malaria.

  7. Quantification of protein thiols and dithiols in the picomolar range using sodium borohydride and 4,4'-dithiodipyridine

    DEFF Research Database (Denmark)

    Hansen, Rosa E; Østergaard, Henrik; Nørgaard, Per

    2007-01-01

    Experimental determination of the number of thiols in a protein requires methodology that combines high sensitivity and reproducibility with low intrinsic thiol oxidation disposition. In detection of disulfide bonds, it is also necessary to efficiently reduce disulfides and to quantify...... the liberated thiols. Ellman's reagent (5,5'-dithiobis-[2-nitrobenzoic acid], DTNB) is the most widely used reagent for quantification of protein thiols, whereas dithiothreitol (DTT) is commonly used for disulfide reduction. DTNB suffers from a relatively low sensitivity, whereas DTT reduction is inconvenient...... sodium borohydride and the thiol reagent 4,4'-dithiodipyridine (4-DPS). Because borohydride is efficiently destroyed by the addition of acid, the complete reduction and quantification can be performed conveniently in one tube without desalting steps. Furthermore, the use of reverse-phase high...

  8. Paper-based microfluidic approach for surface-enhanced raman spectroscopy and highly reproducible detection of proteins beyond picomolar concentration.

    Science.gov (United States)

    Saha, Arindam; Jana, Nikhil R

    2015-01-14

    Although microfluidic approach is widely used in various point of care diagnostics, its implementation in surface enhanced Raman spectroscopy (SERS)-based detection is challenging. This is because SERS signal depends on plasmonic nanoparticle aggregation induced generation of stable electromagnetic hot spots and in currently available microfluidic platform this condition is difficult to adapt. Here we show that SERS can be adapted using simple paper based microfluidic system where both the plasmonic nanomaterials and analyte are used in mobile phase. This approach allows analyte induced controlled particle aggregation and electromagnetic hot spot generation inside the microfluidic channel with the resultant SERS signal, which is highly reproducible and sensitive. This approach has been used for reproducible detection of protein in the pico to femtomolar concentration. Presented approach is simple, rapid, and cost-effective, and requires low sample volume. Method can be extended for SERS-based detection of other biomolecules.

  9. MRI Primer

    International Nuclear Information System (INIS)

    Oldendorf, W.; Oldendorf, W. Jr.

    1991-01-01

    Designed for studies, radiologists, and clinicians at all levels of training, this book provides a basic introduction to the principles, physics, and instrumentation of magnetic resonance imaging. The fundamental concepts that are essential for the optimal clinical use of MRI are thoroughly explained in easily accessible terms. To facilitate the reader's comprehension, the material is presented nonmathematically, using no equations and a minimum of symbols and abbreviations. MRI Primer presents a clear account of the phenomenon of nuclear magnetic resonance and the use of gradient magnetic fields to create clinically useful images of cross-sectional slices. Close attention is given to the magnetization vector as a means of expressing nuclear behavior, the role of T 1 and T 2 weighing in imaging, the use of contrast agents, and the pulse sequences most often used in clinical practice, as well as to the relative capabilities and limitations of MRI and CT. The basic hardware components of an MRI scanner are described in detail. Sample MRI scans illustrate how MRI characterizes tissue. An appendix provides a brief introduction to quantum processes in MRI

  10. A Simple Assay for Ultrasensitive Colorimetric Detection of Ag⁺ at Picomolar Levels Using Platinum Nanoparticles.

    Science.gov (United States)

    Wang, Yi-Wei; Wang, Meili; Wang, Lixing; Xu, Hui; Tang, Shurong; Yang, Huang-Hao; Zhang, Lan; Song, Hongbo

    2017-11-02

    In this work, uniformly-dispersed platinum nanoparticles (PtNPs) were synthesized by a simple chemical reduction method, in which citric acid and sodium borohydride acted as a stabilizer and reducer, respectively. An ultrasensitive colorimetric sensor for the facile and rapid detection of Ag⁺ ions was constructed based on the peroxidase mimetic activities of the obtained PtNPs, which can catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by H₂O₂ to produce colored products. The introduced Ag⁺ would be reduced to Ag⁰ by the capped citric acid, and the deposition of Ag⁰ on the PtNPs surface, can effectively inhibit the peroxidase-mimetic activity of PtNPs. Through measuring the maximum absorption signal of oxidized TMB at 652 nm, ultra-low detection limits (7.8 pM) of Ag⁺ can be reached. In addition to such high sensitivity, the colorimetric assay also displays excellent selectivity for other ions of interest and shows great potential for the detection of Ag⁺ in real water samples.

  11. Picomolar concentrations of morphine in human urine determined by dansyl derivatization and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Lamshöft, Marc; Grobe, Nadja; Spiteller, Michael

    2011-04-15

    Morphine is present in varying amounts as an endogenous product in human urine. Derivatization of morphine contained in urine with dansyl chloride yields a known product, which can be quantified by liquid chromatography mass spectrometry with high selectivity and sensitivity. Urine samples of 51 healthy individuals were spiked with stable-isotope labeled morphine, hydrolyzed and subjected to solid phase extraction followed by derivatization of morphine with dansyl chloride. The dansyl derivatives of naturally occurring morphine and deuterated internal standard were then detected by liquid chromatography-triple quadrupole mass spectrometry. Using the [N-CD(3)]-labeled internal standard and solid-phase extraction, a limit of detection of 35 fmol/ml (10 pg/ml) and a limit of quantification of 87.5 fmol/ml (25 pg/ml) was determined for morphine in human urine. This new LC-MS/MS method allowed the detection of endogenous morphine in human urine of 51 volunteers with an average value of 156.4 fmol/ml (44.7 ng/ml). Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Head MRI

    Science.gov (United States)

    ... hearing aids Pins, hairpins, metal zippers, and similar metallic items Removable dental work How the Test will ... an MRI can make heart pacemakers and other implants not work as well. It can also cause ...

  13. Pediatric MRI

    Data.gov (United States)

    U.S. Department of Health & Human Services — The NIH Study of Normal Brain Development is a longitudinal study using anatomical MRI, diffusion tensor imaging (DTI), and MR spectroscopy (MRS) to map pediatric...

  14. Real-time, single-step bioassay using nanoplasmonic resonator with ultra-high sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiang; Ellman, Jonathan A; Chen, Fanqing Frank; Su, Kai-Hang; Wei, Qi-Huo; Sun, Cheng

    2014-04-01

    A nanoplasmonic resonator (NPR) comprising a metallic nanodisk with alternating shielding layer(s), having a tagged biomolecule conjugated or tethered to the surface of the nanoplasmonic resonator for highly sensitive measurement of enzymatic activity. NPRs enhance Raman signals in a highly reproducible manner, enabling fast detection of protease and enzyme activity, such as Prostate Specific Antigen (paPSA), in real-time, at picomolar sensitivity levels. Experiments on extracellular fluid (ECF) from paPSA-positive cells demonstrate specific detection in a complex bio-fluid background in real-time single-step detection in very small sample volumes.

  15. Formal MRI criteria for the diagnosis of multiple sclerosis

    International Nuclear Information System (INIS)

    Harting, I.; Haehnel, S.; Meyding-Lamade, U.

    2004-01-01

    Multiple scloris (MS) is the most common demyelinating inflammatory disease of the central nervous system, presenting with multifocal, disseminated white matter lesions called plaques. Magnetic resonance imaging (MRI) is very sensitive in detecting white matter abnormalities. By demonstrating the spatial and temporal dissemination in patients presenting with isolated clinical findings suggestive of MS, MRI contributes to estimating the likelihood of the disease. Since MRI is highly sensitive but not specific, it is important to apply formal MRI criteria. This article describes the characteristic MRI changes of MS and the so-called McDonald criteria for an MRI-supported diagnosis of MS. (orig.) [de

  16. Portable MRI

    Energy Technology Data Exchange (ETDEWEB)

    Espy, Michelle A. [Los Alamos National Laboratory

    2012-06-29

    This project proposes to: (1) provide the power of MRI to situations where it presently isn't available; (2) perform the engineering required to move from lab to a functional prototype; and (3) leverage significant existing infrastructure and capability in ultra-low field MRI. The reasons for doing this: (1) MRI is the most powerful tool for imaging soft-tissue (e.g. brain); (2) Billions don't have access due to cost or safety issues; (3) metal will heat/move in high magnetic fields; (4) Millions of cases of traumatic brain injury in US alone; (5) even more of non-traumatic brain injury; (6) (e.g. stroke, infection, chemical exposure); (7) Need for early diagnostic; (8) 'Signature' wound of recent conflicts; (9) 22% of injuries; (10) Implications for post-traumatic stress disorder; and (11) chronic traumatic encephalopathy.

  17. Portable MRI

    International Nuclear Information System (INIS)

    Espy, Michelle A.

    2012-01-01

    This project proposes to: (1) provide the power of MRI to situations where it presently isn't available; (2) perform the engineering required to move from lab to a functional prototype; and (3) leverage significant existing infrastructure and capability in ultra-low field MRI. The reasons for doing this: (1) MRI is the most powerful tool for imaging soft-tissue (e.g. brain); (2) Billions don't have access due to cost or safety issues; (3) metal will heat/move in high magnetic fields; (4) Millions of cases of traumatic brain injury in US alone; (5) even more of non-traumatic brain injury; (6) (e.g. stroke, infection, chemical exposure); (7) Need for early diagnostic; (8) 'Signature' wound of recent conflicts; (9) 22% of injuries; (10) Implications for post-traumatic stress disorder; and (11) chronic traumatic encephalopathy.

  18. Implied motion because of instability in Hokusai Manga activates the human motion-sensitive extrastriate visual cortex: an fMRI study of the impact of visual art.

    Science.gov (United States)

    Osaka, Naoyuki; Matsuyoshi, Daisuke; Ikeda, Takashi; Osaka, Mariko

    2010-03-10

    The recent development of cognitive neuroscience has invited inference about the neurosensory events underlying the experience of visual arts involving implied motion. We report functional magnetic resonance imaging study demonstrating activation of the human extrastriate motion-sensitive cortex by static images showing implied motion because of instability. We used static line-drawing cartoons of humans by Hokusai Katsushika (called 'Hokusai Manga'), an outstanding Japanese cartoonist as well as famous Ukiyoe artist. We found 'Hokusai Manga' with implied motion by depicting human bodies that are engaged in challenging tonic posture significantly activated the motion-sensitive visual cortex including MT+ in the human extrastriate cortex, while an illustration that does not imply motion, for either humans or objects, did not activate these areas under the same tasks. We conclude that motion-sensitive extrastriate cortex would be a critical region for perception of implied motion in instability.

  19. Fetal MRI

    International Nuclear Information System (INIS)

    Prayer, D.; Brugger, P.C.

    2004-01-01

    New, ultrafast sequences have made it possible to obtain MR images of the fetus without maternal sedation or immobilization of the fetus itself. While fetal MRI began as an adjunct to ultrasound, it has now been shown that MRI can provide additional information that may change prognosis, the management of pregnancy, or the treatment of the newborn child. It is of particular value in the assessment of malformations of the central nervous system. The steady development and adaptation of MR-sequences to the needs of fetal imaging has led to new indications that can support prognostic and therapeutic decisions. (orig.)

  20. Interventional MRI

    Energy Technology Data Exchange (ETDEWEB)

    Harada, Junta; Dohi, Michiko; Yoshihiro, Akiko; Mogami, Takuji; Kuwada, Tomoko; Nakata, Norio [Jikei Univ., Chiba (Japan). Kashiwa Hospital

    2000-06-01

    Open type MR system and fast sequence is now available and MRI becomes a new modality for interventional Radiology, including biopsy, drainage operation, and monitoring for minimally invasive therapy. Experimental studies of temperature monitoring were performed under hot and cold status. Signal changes of porcine disc and meat under microwave and laser ablation were observed as low signal area by signal intensity method. Using proton chemical shift method, signal change by laser ablation was displaced color imaging and correlated with thermometric temperature measurement. The very T2 relaxation time of ice affords excellent contrast between ice and surrounding gelatin tissue allowing acute depiction of the extent of the iceball under MRI. (author)

  1. Fetal MRI

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, D.; Brugger, P.C. [University Hospital of Vienna (Austria). Division of Neuroradiology

    2004-07-01

    New, ultrafast sequences have made it possible to obtain MR images of the fetus without maternal sedation or immobilization of the fetus itself. While fetal MRI began as an adjunct to ultrasound, it has now been shown that MRI can provide additional information that may change prognosis, the management of pregnancy, or the treatment of the newborn child. It is of particular value in the assessment of malformations of the central nervous system. The steady development and adaptation of MR-sequences to the needs of fetal imaging has led to new indications that can support prognostic and therapeutic decisions. (orig.)

  2. Very large fMRI study using the IMAGEN database: Sensitivity-specificity and population effect modeling in relation to the underlying anatomy

    International Nuclear Information System (INIS)

    Thyreau, Benjamin; Schwartz, Yannick; Thirion, Bertrand; Frouin, Vincent; Loth, Eva; Conrod, Patricia J.; Schumann, Gunter; Vollstadt-Klein, Sabine; Paus, Tomas; Artiges, Eric; Whelan, Robert; Poline, Jean-Baptiste

    2012-01-01

    In this paper we investigate the use of classical fMRI Random Effect (RFX) group statistics when analyzing a very large cohort and the possible improvement brought from anatomical information. Using 1326 subjects from the IMAGEN study, we first give a global picture of the evolution of the group effect t-value from a simple face-watching contrast with increasing cohort size. We obtain a wide activated pattern, far from being limited to the reasonably expected brain areas, illustrating the difference between statistical significance and practical significance. This motivates us to inject tissue-probability information into the group estimation, we model the BOLD contrast using a matter-weighted mixture of Gaussians and compare it to the common, single-Gaussian model. In both cases, the model parameters are estimated per-voxel for one subgroup, and the likelihood of both models is computed on a second, separate subgroup to reflect model generalization capacity. Various group sizes are tested, and significance is asserted using a 10-fold cross-validation scheme. We conclude that adding matter information consistently improves the quantitative analysis of BOLD responses in some areas of the brain, particularly those where accurate inter-subject registration remains challenging. (authors)

  3. Reward Anticipation in Ventral Striatum and Individual Sensitivity to Reward: A Pilot Study of a Child-Friendly fMRI Task.

    Science.gov (United States)

    van Hulst, Branko M; de Zeeuw, Patrick; Lupas, Kellina; Bos, Dienke J; Neggers, Sebastiaan F W; Durston, Sarah

    2015-01-01

    Reward processing has been implicated in developmental disorders. However, the classic task to probe reward anticipation, the monetary incentive delay task, has an abstract coding of reward and no storyline and may therefore be less appropriate for use with developmental populations. We modified the task to create a version appropriate for use with children. We investigated whether this child-friendly version could elicit ventral striatal activation during reward anticipation in typically developing children and young adolescents (aged 9.5-14.5). In addition, we tested whether our performance-based measure of reward sensitivity was associated with anticipatory activity in ventral striatum. Reward anticipation was related to activity in bilateral ventral striatum. Moreover, we found an association between individual reward sensitivity and activity in ventral striatum. We conclude that this task assesses ventral striatal activity in a child-friendly paradigm. The combination with a performance-based measure of reward sensitivity potentially makes the task a powerful tool for developmental imaging studies of reward processing.

  4. MRI appearance of muscle denervation

    Energy Technology Data Exchange (ETDEWEB)

    Kamath, S. [University Hospital of Wales, Department of Radiology, Cardiff (United Kingdom); Venkatanarasimha, N.; Walsh, M.A.; Hughes, P.M. [Derriford Hospital, Department of Radiology, Plymouth (United Kingdom)

    2008-05-15

    Muscle denervation results from a variety of causes including trauma, neoplasia, neuropathies, infections, autoimmune processes and vasculitis. Traditionally, the diagnosis of muscle denervation was based on clinical examination and electromyography. Magnetic resonance imaging (MRI) offers a distinct advantage over electromyography, not only in diagnosing muscle denervation, but also in determining its aetiology. MRI demonstrates characteristic signal intensity patterns depending on the stage of muscle denervation. The acute and subacutely denervated muscle shows a high signal intensity pattern on fluid sensitive sequences and normal signal intensity on T1-weighted MRI images. In chronic denervation, muscle atrophy and fatty infiltration demonstrate high signal changes on T1-weighted sequences in association with volume loss. The purpose of this review is to summarise the MRI appearance of denervated muscle, with special emphasis on the signal intensity patterns in acute and subacute muscle denervation. (orig.)

  5. MRI angiography

    International Nuclear Information System (INIS)

    Poncelet, B.; Baleriiaux, D.; struyven, J.; Segebarth, C.

    1989-01-01

    In MRI angiography two basis images are measured which only differ by the signal intensity of the flowing blood in the vessels. Subtraction of these two images produces a high contrast-to-noise representation of the vessels. Contrast between stationary tissues and flowing blood is changed, for one image compared to the second one, using a selective modification of the phase of the signal from the flowing blood, and/or using a selective modification of its longitudinal magnetization: The macroscopic spin motions along the selection and the measurement gradient directions affect the phase of the nuclear signal; assuming constant velocity, the phase is proportional to the velocity and to the first moment of the gradient waveforms applied. This work concentrates on the generarion of MRI angiograms, following a phase-based approach, of the carotid bifurcation and of different intracranical regions including the carotid syphon and the circle of Willis. (author). 21 refs.; 3 figs

  6. Functional MRI experiments : acquisition, analysis and interpretation of data

    NARCIS (Netherlands)

    Ramsey, NF; Hoogduin, H; Jansma, JM

    2002-01-01

    Functional MRI is widely used to address basic and clinical neuroscience questions. In the key domains of fMRI experiments, i.e. acquisition, processing and analysis, and interpretation of data, developments are ongoing. The main issues are sensitivity for changes in fMRI signal that are associated

  7. MRI zoo

    DEFF Research Database (Denmark)

    Laustsen, Christoffer

    The basic idea was to use MRI to produce a sequence of 3D gray scale image slices of various animals, subsequentlyimaged with a clinical CT system. For this purpose, these animals were used: toad, lungfish, python snake and a horseshoe crab. Each animal was sacrificed according to standard...... visually inspected, both in 2D and 3D, and compared with photographs and anatomy atlases found at library and on the internet....

  8. 1,3-Oxazole-based selective picomolar inhibitors of cytosolic human carbonic anhydrase II alleviate ocular hypertension in rabbits: Potency is supported by X-ray crystallography of two leads.

    Science.gov (United States)

    Ferraroni, Marta; Lucarini, Laura; Masini, Emanuela; Korsakov, Mikhail; Scozzafava, Andrea; Supuran, Claudiu T; Krasavin, Mikhail

    2017-09-01

    Two lead 1,3-oxazole-based carbonic anhydrase inhibitors (CAIs) earlier identified as selective, picomolar inhibitors of hCA II (a cytosolic target for treatment of glaucoma) have been investigated further. Firstly, they were found to be conveniently synthesized on multigram scale, which enables further development. These compounds were found to be comparable in efficacy to dorzolamide eye drops when applied in the eye drop form as well. Finally, the reasons for unusually high potency of these compounds became understood from their high-resolution X-ray crystallography structures. These data significantly expand our understanding of heterocycle-based primary sulfonamides, many of which have recently emerged from our labs - particularly, from the corneal permeability standpoint. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Comparison of diffusion-weighted fMRI and BOLD fMRI responses in a verbal working memory task

    International Nuclear Information System (INIS)

    Aso, Toshihiko; Urayama, Shin-ichi; Fukuyama, Hidenao; Le Bihan, Denis

    2013-01-01

    Diffusion-weighted functional MRI (DfMRI) has been reported to have a different response pattern in the visual cortex than that of BOLD-fMRI. Especially, the DfMRI signal shows a constantly faster response at both onset and offset of the stimulus, suggesting that the DfMRI signal might be more directly linked to neuronal events than the hemodynamic response. However, because the DfMRI response also contains a residual sensitivity to BOLD this hypothesis has been challenged. Using a verbal working memory task we show that the DfMRI time-course features are preserved outside visual cortices, but also less liable to between-subject/between-regional variation than the BOLD response. The overall findings not only support the feasibility of DfMRI as an approach for functional brain imaging, but also strengthen the uniqueness of the DfMRI signal origin. (authors)

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... affecting the MRI images, these objects can become projectiles within the MRI scanner room and may cause ... MRI has proven valuable in diagnosing a broad range of conditions, including cancer, heart and vascular disease, ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... or patients with claustrophobia. Other MRI machines are open on the sides (open MRI). Open units are especially helpful for examining larger patients or those with claustrophobia. Newer open MRI units provide very high quality images for ...

  12. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Magnetic Resonance Imaging (MRI) is a medical imaging procedure for ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... does not completely surround you. Some newer MRI machines have a larger diameter bore which can be ... size patients or patients with claustrophobia. Other MRI machines are open on the sides (open MRI). Open ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... in the first three to four months of pregnancy unless the potential benefit from the MRI exam ... the MRI Safety page for more information about pregnancy and MRI. If you have claustrophobia (fear of ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Chest Magnetic resonance imaging (MRI) ... clearer and more detailed than with other imaging methods. This detail makes MRI an invaluable tool in ...

  16. Play the MRI Game

    Science.gov (United States)

    ... Teachers' Questionnaire MRI Play MRI the Magnetic Miracle Game About the game In the MRI imaging technique, strong magnets and ... last will in Paris. Play the Blood Typing Game Try to save some patients and learn about ...

  17. MRI imaging in pediatric appendicitis

    Directory of Open Access Journals (Sweden)

    Robin Riley

    2018-04-01

    Full Text Available An 8-year-old male presents with two days of abdominal pain and emesis. Computed tomography was concerning for obstruction or reactive ileus with an apparent transition point in the right lower quadrant, possibly due to Crohn's. Magnetic resonance imaging was concerning for perforated appendicitis. As demonstrated by this case MRI can be as sensitive as CT in detecting pediatric appendicitis [2]. We recommend using MRI instead of CT to diagnose appendicitis to avoid ionizing radiation and increased cancer risk in the pediatric population. Keywords: Computer tomography, Magnetic resonance imaging, Pediatric appendicitis

  18. Animal MRI Core

    Data.gov (United States)

    Federal Laboratory Consortium — The Animal Magnetic Resonance Imaging (MRI) Core develops and optimizes MRI methods for cardiovascular imaging of mice and rats. The Core provides imaging expertise,...

  19. The potential of multiparametric MRI of the breast

    Science.gov (United States)

    Pinker, Katja; Helbich, Thomas H

    2017-01-01

    MRI is an essential tool in breast imaging, with multiple established indications. Dynamic contrast-enhanced MRI (DCE-MRI) is the backbone of any breast MRI protocol and has an excellent sensitivity and good specificity for breast cancer diagnosis. DCE-MRI provides high-resolution morphological information, as well as some functional information about neoangiogenesis as a tumour-specific feature. To overcome limitations in specificity, several other functional MRI parameters have been investigated and the application of these combined parameters is defined as multiparametric MRI (mpMRI) of the breast. MpMRI of the breast can be performed at different field strengths (1.5–7 T) and includes both established (diffusion-weighted imaging, MR spectroscopic imaging) and novel MRI parameters (sodium imaging, chemical exchange saturation transfer imaging, blood oxygen level-dependent MRI), as well as hybrid imaging with positron emission tomography (PET)/MRI and different radiotracers. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the underlying oncogenic processes of cancer development and progression and can provide additional specificity. This article will review the current and emerging functional parameters for mpMRI of the breast for improved diagnostic accuracy in breast cancer. PMID:27805423

  20. MRI diagnosis of eyeball diseases

    International Nuclear Information System (INIS)

    Tao Xiaofeng; Shi Zengru; Xiao Xiangsheng; Yu Hong; Wei Ruili

    2003-01-01

    Objective: To review the MR imaging of eyeball mass in 75 patients with the intention to enhance the acknowledgement to eyeball diseases. Methods: Seventy-five patients, 45 males and 30 females, were examined with MRI before treatment. Most MRI studies were performed with head coil and a few with orbit surface coil. Sagittal, coronal, and axial images were attained. Enhanced MRI studies were performed in 37 cases. High magnetic field MRI studies were performed with additional fat saturation technique. Results: Retinoblastoma (20 cases) showed isointensity in 11 and low signal intensity in 9 on T 1 WI, and isointensity in 5 and slight high signal in 15 on T 2 WI. Coats' disease (5 cases) involved single eyeball in all cases without calcification or eyeball enlargement, and presented as slight high signal on T 1 WI and high signal on T 2 WI. Choroidal angioma (3 cases) showed slight high signal on T 1 WI and high signal on T 2 WI. Metastasis (20 cases) was located in the posterior wall of the eyeball. Extra-global invasion occurred in 8 cases and intra-global invasion in 20. Marked thickening of the global wall with isointensity (8 cases) or low signal intensity (12 cases) was detected on T 1 WI, and isointensity (6 cases) or slight high signal intensity (14 cases) was demonstrated on T 2 WI. Marked enhancement was revealed in all 15 cases. Melanoma (7 cases) showed high signal intensity (5) and isointensity (2) on T 1 WI, and low signal (7) on T 2 WI. Retinal detachment (19 cases) showed high signal on both T 1 and T 2 WI, etc. In the diagnosis of eyeball diseases with MRI, the total sensitivity was 100% and specificity was 86.7%. Conclusions: MRI imaging is an important examination method to eyeball diseases, and most diagnosis and differential diagnosis of eyeball diseases can be made correctly with MRI

  1. Whole-body MRI screening

    Energy Technology Data Exchange (ETDEWEB)

    Puls, Ralf [HELIOS Klinikum Erfurt (Germany). Inst. of Diagnostic and Interventional Radiology and Neuroradiology; Hosten, Norbert (ed.) [Universitaetsklinikum Greifswald (Germany). Diagnostic Radiology and Neuroradiology

    2014-07-01

    The advent of dedicated whole-body MRI scanners has made it possible to image the human body from head to toe with excellent spatial resolution and with the sensitivity and specificity of conventional MR systems. A comprehensive screening examination by MRI relies on fast image acquisition, and this is now feasible owing to several very recent developments, including multichannel techniques, new surface coil systems, and automatic table movement. The daily analysis of whole-body MRI datasets uncovers many incidental findings, which are discussed by an interdisciplinary advisory board of physicians from all specialties. This book provides a systematic overview of these incidental findings with the aid of approximately 240 high-quality images. The radiologists involved in the project have written chapters on each organ system, presenting a structured compilation of the most common findings, their morphologic appearances on whole-body MRI, and guidance on their clinical management. Chapters on technical and ethical issues are also included. It is hoped that this book will assist other diagnosticians in deciding how to handle the most common incidental findings encountered when performing whole-body MRI.

  2. MRI in ischemic brain diseases

    International Nuclear Information System (INIS)

    Steinbrich, W.; Friedmann, G.; Pawlik, G.; Boecher-Schwarz, H.G.; Heiss, W.D.

    1986-01-01

    The results of MRI and CT in 55 patients with brain infarcts were compared; in 26 of these cases an additional PET examination was obtained in order to study the regional glucose utilisation. MRI was superior to CT, demonstrating 11% more of the infarcts, particularly during the first 24 hours, in small lesions confined to the grey or subcortical white matter and in infratentorial ischemic lesion. On the other hand, only CT was able to show fresh hemorrhage, although MRI was the method of choice to demonstrate old blood collections. To characterise the follow up of an infarct, CT and MRI were similar, except the marginal contrast enhancement sometimes demonstrated by CT studies between the 2nd and 4th week after stroke event. PET was inferior to show details because of its poorer spatial resolution, but anyhow had a high sensitivity and provided additional informations concerning secondary inactivations of brain areas not directly damaged. Additionally PET was able to demonstrate areas of anaerobic glycolysis and lesions of diminished glucose utilisation in TIAs. Small areas of gliosis in the white matter of the cerebral hemispheres were frequently found in patients with cerebro-vascular diseases; they were best shown by MRI, but do not correlate with the extent of vascular stenoses or occlusions, shown by angiography. (orig) [de

  3. Whole-body MRI screening

    International Nuclear Information System (INIS)

    Puls, Ralf; Hosten, Norbert

    2014-01-01

    The advent of dedicated whole-body MRI scanners has made it possible to image the human body from head to toe with excellent spatial resolution and with the sensitivity and specificity of conventional MR systems. A comprehensive screening examination by MRI relies on fast image acquisition, and this is now feasible owing to several very recent developments, including multichannel techniques, new surface coil systems, and automatic table movement. The daily analysis of whole-body MRI datasets uncovers many incidental findings, which are discussed by an interdisciplinary advisory board of physicians from all specialties. This book provides a systematic overview of these incidental findings with the aid of approximately 240 high-quality images. The radiologists involved in the project have written chapters on each organ system, presenting a structured compilation of the most common findings, their morphologic appearances on whole-body MRI, and guidance on their clinical management. Chapters on technical and ethical issues are also included. It is hoped that this book will assist other diagnosticians in deciding how to handle the most common incidental findings encountered when performing whole-body MRI.

  4. MRI diagnosis of meniscal tears

    International Nuclear Information System (INIS)

    Kuga, Naoyuki; Oh, Toshihiro

    1996-01-01

    We studied the accuracy of magnetic resonance imaging (MRI) of the knee in fifty-six patients who were also examined arthroscopically. The accuracy, sensitivity, and specificity were 96%, 100%, and 95% for medial meniscal tears, and 91%, 67%, and 100% for lateral meniscal tears respectively. Two MRIs of the medial meniscus were false-positives. These MRI findings were both meniscocapsular separation of the medial meniscus, but the arthroscopic findings were normal. One case was an ACL injury and the other PCL and MCL injury. Hemorrhage and edema of the medial capsule caused by valgus stress at injury may look like a meniscal pseudo-tear on MRI. Five MRIs of the lateral meniscus were false-negatives. All menisci showed normal signal and shape on MRI but traumatic and stable tears of the lateral meniscus were identified arthroscopically. All were associated with ACL tears and lateral condylar bone bruise. The traumatic and stable tear of the meniscus tended to be overlooked on MRI because a meniscus without degeneration shows a normal signal. (author)

  5. MRI in Optic Neuritis: Structure, Function, Interactions

    DEFF Research Database (Denmark)

    Fuglø, Dan

    2011-01-01

    resonance imaging (MRI), and the visual evoked potential (VEP) continues to show a delayed P100 indicating persistent demyelination. The explanation for this apparent discrepancy between structure and function could be due to either a redundancy in the visual pathways so that some degree of signal loss...... will have very few or no clinical symptoms, or it could be due to compensatory mechanisms in the visual pathway or the visual cortex. In order to understand the pathophysiology and recovery processes in ON it is essential to have sensitive methods to asses both structure and function. These methods...... are low. Functional MRI (fMRI) is a non-invasive technique that can measure brain activity with a high spatial resolution. Recently, technical and methodological advancements have made it feasible to record VEPs and fMRI simultaneously and the relationship between averaged VEPs and averaged fMRI signals...

  6. Standard high-resolution pelvic MRI vs. low-resolution pelvic MRI in the evaluation of deep infiltrating endometriosis

    International Nuclear Information System (INIS)

    Scardapane, Arnaldo; Lorusso, Filomenamila; Ferrante, Annunziata; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe; Scioscia, Marco

    2014-01-01

    To compare the capabilities of standard pelvic MRI with low-resolution pelvic MRI using fast breath-hold sequences to evaluate deep infiltrating endometriosis (DIE). Sixty-eight consecutive women with suspected DIE were studied with pelvic MRI. A double-acquisition protocol was carried out in each case. High-resolution (HR)-MRI consisted of axial, sagittal, and coronal TSE T2W images, axial TSE T1W, and axial THRIVE. Low-resolution (LR)-MRI was acquired using fast single shot (SSH) T2 and T1 images. Two radiologists with 10 and 2 years of experience reviewed HR and LR images in two separate sessions. The presence of endometriotic lesions of the uterosacral ligament (USL), rectovaginal septum (RVS), pouch of Douglas (POD), and rectal wall was noted. The accuracies of LR-MRI and HR-MRI were compared with the laparoscopic and histopathological findings. Average acquisition times were 24 minutes for HR-MRI and 7 minutes for LR-MRI. The more experienced radiologist achieved higher accuracy with both HR-MRI and LR-MRI. The values of sensitivity, specificity, PPV, NPV, and accuracy did not significantly change between HR and LR images or interobserver agreement for all of the considered anatomic sites. LR-MRI performs as well as HR-MRI and is a valuable tool for the detection of deep endometriosis extension. (orig.)

  7. Standard high-resolution pelvic MRI vs. low-resolution pelvic MRI in the evaluation of deep infiltrating endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Scardapane, Arnaldo; Lorusso, Filomenamila; Ferrante, Annunziata; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe [University Hospital ' ' Policlinico' ' of Bari, Interdisciplinary Department of Medicine, Bari (Italy); Scioscia, Marco [Sacro Cuore Don Calabria General Hospital, Department of Obstetrics and Gynecology, Negrar, Verona (Italy)

    2014-10-15

    To compare the capabilities of standard pelvic MRI with low-resolution pelvic MRI using fast breath-hold sequences to evaluate deep infiltrating endometriosis (DIE). Sixty-eight consecutive women with suspected DIE were studied with pelvic MRI. A double-acquisition protocol was carried out in each case. High-resolution (HR)-MRI consisted of axial, sagittal, and coronal TSE T2W images, axial TSE T1W, and axial THRIVE. Low-resolution (LR)-MRI was acquired using fast single shot (SSH) T2 and T1 images. Two radiologists with 10 and 2 years of experience reviewed HR and LR images in two separate sessions. The presence of endometriotic lesions of the uterosacral ligament (USL), rectovaginal septum (RVS), pouch of Douglas (POD), and rectal wall was noted. The accuracies of LR-MRI and HR-MRI were compared with the laparoscopic and histopathological findings. Average acquisition times were 24 minutes for HR-MRI and 7 minutes for LR-MRI. The more experienced radiologist achieved higher accuracy with both HR-MRI and LR-MRI. The values of sensitivity, specificity, PPV, NPV, and accuracy did not significantly change between HR and LR images or interobserver agreement for all of the considered anatomic sites. LR-MRI performs as well as HR-MRI and is a valuable tool for the detection of deep endometriosis extension. (orig.)

  8. Methodological principles for optimising functional MRI experiments

    International Nuclear Information System (INIS)

    Wuestenberg, T.; Giesel, F.L.; Strasburger, H.

    2005-01-01

    Functional magnetic resonance imaging (fMRI) is one of the most common methods for localising neuronal activity in the brain. Even though the sensitivity of fMRI is comparatively low, the optimisation of certain experimental parameters allows obtaining reliable results. In this article, approaches for optimising the experimental design, imaging parameters and analytic strategies will be discussed. Clinical neuroscientists and interested physicians will receive practical rules of thumb for improving the efficiency of brain imaging experiments. (orig.) [de

  9. Gadolinium-DTPA enhanced MRI of the brain

    International Nuclear Information System (INIS)

    Hosten, N.; Felix, R.

    1994-01-01

    The text reviews MRI findings in a variety of cerebral diseases. Advantages of Gadolinium-DTPA (Gd-DTPA) enhanced MRI over plain MRI and enhanced CT are discussed. Enhanced MRI is far superior to enhanced CT in the detection of meningeal tumor spread, meningeal inflammation, inflammatory lesions of the optic nerve, brain lesions in multiple sclerosis and infarction. Enhanced MRI is today the most sensitive diagnostic tool in hypophaseal adenomas. Also enhancement of gliomas is detected by MRI with higher sensitivity than by CT. Use Gd-DTPA allow to separate of vital tumor tissue from necrosis and edema, improve delineation of tumor extension and improve detection of lesions localized in gray matter

  10. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how ... What is MRI and how does it work? Magnetic resonance imaging, or MRI, is a way of obtaining ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... examination poses almost no risk to the average patient when appropriate safety guidelines are followed. If sedation is used, there ... patient story here Images × ... Imaging (MRI) Safety Contrast Materials MRI Safety During Pregnancy Images related ...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. MRI of the chest gives detailed pictures ... over time. top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... images and send a signed report to your primary care or referring physician, who will share the ... This detail makes MRI an invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... interfere with the magnetic field of the MRI unit, metal and electronic items are not allowed in ... does the equipment look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms that ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... women should not have this exam in the first three to four months of pregnancy unless the ... not to have an MRI exam during the first trimester unless medically necessary. MRI may not always ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... important to assess the health and function of these structures (heart, valves, great vessels, etc.). top of ... room. In addition to affecting the MRI images, these objects can become projectiles within the MRI scanner ...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ...

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Chest? What is MRI of the Chest? Magnetic resonance imaging ( ... heart, valves, great vessels, etc.). top of page What are some common uses of the procedure? MR ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... MRI an invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has proven valuable in ...

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... used in MRI exams is less likely to produce an allergic reaction than the iodine-based contrast ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played ... the limitations of MRI of the Chest? High-quality images are assured only if you are able ...

  5. MRI of the Chest

    Science.gov (United States)

    ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... clearer and more detailed than with other imaging methods. This detail makes MRI an invaluable tool in ... might be obscured by bone with other imaging methods. The contrast material used in MRI exams is ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ... risking the side effects of conventional (catheter) angiography . Risks The MRI examination poses almost no risk to ...

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI examination poses almost no risk to the average patient when appropriate safety guidelines are followed. If ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... other internal body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians ... computed tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... This detail makes MRI an invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography ( ...

  12. Canalis basilaris medianus: MRI

    International Nuclear Information System (INIS)

    Jacquemin, C.; Bosley, T.M.; Al Saleh, M.; Mullaney, P.

    2000-01-01

    We report the MRI appearances of an developmental anatomical variant of the basiocciput, with neuroimaging findings (CT and MRI). Such variants are commonly asymptomatic, but may be associated with episodes of meningitis. (orig.)

  13. Whole-body MRI, dynamic contrast-enhanced MRI, and diffusion-weighted imaging for the staging of multiple myeloma

    Energy Technology Data Exchange (ETDEWEB)

    Dutoit, Julie C.; Verstraete, Koenraad L. [Ghent University Hospital, Department of Radiology, Ghent (Belgium)

    2017-06-15

    Magnetic resonance imaging (MRI) is the most sensitive imaging technique for the detection of bone marrow infiltration, and has therefore recently been included in the new diagnostic myeloma criteria, as proposed by the International Myeloma Working Group. Nevertheless, conventional MRI only provides anatomical information and is therefore only of limited use in the response assessment of patients with multiple myeloma. The additional information from functional MRI techniques, such as diffusion-weighted imaging and dynamic contrast-enhanced MRI, can improve the detection rate of bone marrow infiltration and the assessment of response. This can further enhance the sensitivity and specificity of MRI in the staging of multiple myeloma patients. This article provides an overview of the technical aspects of conventional and functional MRI techniques with practical recommendations. It reviews the diagnostic performance, prognostic value, and role in therapy assessment in multiple myeloma and its precursor stages. (orig.)

  14. MRI in acute poliomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Kornreich, L. [Imaging Department, The Schneider Children`s Medical Centre of Israel, Kaplan Street, Petah Tiqva 49202 (Israel)]|[Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Dagan, O. [The Intensive Care Unit, The Schneider Children`s Medical Centre of Israel, Beilinson Medical Campus, Petah Tiqva (Israel)]|[Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Grunebaum, M. [Imaging Department, The Schneider Children`s Medical Centre of Israel, Kaplan Street, Petah Tiqva 49202 (Israel)]|[Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel)

    1996-05-01

    MRI can be used in the diagnosis of anterior horn infection and for assessing the extent of disease. There are no specific MRI signs to differentiate between the various possible pathogens. This is demonstrated in the present case of poliomyelitis, in which MRI of the spine played an important role in establishing the diagnosis. (orig.). With 1 fig.

  15. MRI in acute poliomyelitis

    International Nuclear Information System (INIS)

    Kornreich, L.; Dagan, O.; Grunebaum, M.

    1996-01-01

    MRI can be used in the diagnosis of anterior horn infection and for assessing the extent of disease. There are no specific MRI signs to differentiate between the various possible pathogens. This is demonstrated in the present case of poliomyelitis, in which MRI of the spine played an important role in establishing the diagnosis. (orig.). With 1 fig

  16. MRI Reporter Genes for Noninvasive Molecular Imaging

    Directory of Open Access Journals (Sweden)

    Caixia Yang

    2016-05-01

    Full Text Available Magnetic resonance imaging (MRI is one of the most important imaging technologies used in clinical diagnosis. Reporter genes for MRI can be applied to accurately track the delivery of cell in cell therapy, evaluate the therapy effect of gene delivery, and monitor tissue/cell-specific microenvironments. Commonly used reporter genes for MRI usually include genes encoding the enzyme (e.g., tyrosinase and β-galactosidase, the receptor on the cells (e.g., transferrin receptor, and endogenous reporter genes (e.g., ferritin reporter gene. However, low sensitivity limits the application of MRI and reporter gene-based multimodal imaging strategies are common including optical imaging and radionuclide imaging. These can significantly improve diagnostic efficiency and accelerate the development of new therapies.

  17. Neurodegenerative diseases of the central motor system in MRI

    International Nuclear Information System (INIS)

    Alfke, K.

    2005-01-01

    Neurodegenerative diseases of the central motor system often lead to discrete but functionally important parenchymal abnormalities in various parts of the brain. MRI is the most sensitive imaging method to detect these abnormalities. Various neurodegenerative diseases are presented with their clinical symptoms and MRI findings. Criteria for differential diagnosis are provided as well. (orig.)

  18. Analysis and visualization methods for interpretation of diffusion MRI data

    NARCIS (Netherlands)

    Vos, S.B.

    2013-01-01

    Diffusion MRI is an imaging technique that is very sensitive to microstructural changes in tissue. Diffusion tensor MRI, the most commonly used method, can estimate the magnitude and anisotropy of diffusion. These tensor-based diffusion parameters have been shown to change in many neuropathological

  19. [MRI methods for pulmonary ventilation and perfusion imaging].

    Science.gov (United States)

    Sommer, G; Bauman, G

    2016-02-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O2-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies.

  20. MRI methods for pulmonary ventilation and perfusion imaging

    International Nuclear Information System (INIS)

    Sommer, G.; Bauman, G.

    2016-01-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O 2 -enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies. (orig.) [de

  1. Diagnosis of triangular fibrocartilage complex injury using arthrography and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Kiyonobu; Soejima, Osamu; Naito, Masatoshi [Fukuoka Univ. (Japan). School of Medicine

    2001-09-01

    Twenty patients (twenty-one wrists) with chronic ulnar wrist pain who had undergone radiocarpal arthrography and MRI before arthroscopic examination were evaluated to determine the usefulness of these preoperative diagnostic procedures (arthrogrphy and MRI) for the detection of triangular fibrocartilage complex (TFCC) injury. Based on the arthroscopic findings, the sensitivity and specificity of arthrography were 63% and 100% respectively for detecting TFCC lesions, while they were 68% and 50% respectively for MRI. Although no significant superiority was observed between arthrography and MRI in this study, further improrumchts in the preoperative diagnostic procedures are still needed in order to more accurately detect TFCC injuries. (author)

  2. MRI comes of age in RA clinical trials

    DEFF Research Database (Denmark)

    Peterfy, Charles; Østergaard, Mikkel; Conaghan, Philip G

    2013-01-01

    meant difficulties in differentiating structural progression using traditional radiographic outcome measures. Magnetic resonance imaging (MRI) has been demonstrated to assess damage more sensitively than radiographs, but importantly it can measure the upstream drivers of erosions and cartilage loss...

  3. Comparison between breast MRI and contrast-enhanced spectral mammography.

    Science.gov (United States)

    Łuczyńska, Elżbieta; Heinze-Paluchowska, Sylwia; Hendrick, Edward; Dyczek, Sonia; Ryś, Janusz; Herman, Krzysztof; Blecharz, Paweł; Jakubowicz, Jerzy

    2015-05-12

    The main goal of this study was to compare contrast-enhanced spectral mammography (CESM) and breast magnetic resonance imaging (MRI) with histopathological results and to compare the sensitivity, accuracy, and positive and negative predictive values for both imaging modalities. After ethics approval, CESM and MRI examinations were performed in 102 patients who had suspicious lesions described in conventional mammography. All visible lesions were evaluated independently by 2 experienced radiologists using BI-RADS classifications (scale 1-5). Dimensions of lesions measured with each modality were compared to postoperative histopathology results. There were 102 patients entered into CESM/MRI studies and 118 lesions were identified by the combination of CESM and breast MRI. Histopathology confirmed that 81 of 118 lesions were malignant and 37 were benign. Of the 81 malignant lesions, 72 were invasive cancers and 9 were in situ cancers. Sensitivity was 100% with CESM and 93% with breast MRI. Accuracy was 79% with CESM and 73% with breast MRI. ROC curve areas based on BI-RADS were 0.83 for CESM and 0.84 for breast MRI. Lesion size estimates on CESM and breast MRI were similar, both slightly larger than those from histopathology. Our results indicate that CESM has the potential to be a valuable diagnostic method that enables accurate detection of malignant breast lesions, has high negative predictive value, and a false-positive rate similar to that of breast MRI.

  4. [MRI semiotics features of experimental acute intracerebral hematomas].

    Science.gov (United States)

    Burenchev, D V; Skvortsova, V I; Tvorogova, T V; Guseva, O I; Gubskiĭ, L V; Kupriianov, D A; Pirogov, Iu A

    2009-01-01

    The aim of this study was to assess the possibility of revealing intracerebral hematomas (ICH), using MRI, within the first hours after onset and to determine their MRI semiotics features. Thirty animals with experimental ICH were studied. A method of two-stage introduction of autologous blood was used to develop ICH as human spontaneous intracranial hematomas. Within 3-5h after blood introduction to the rat brain. The control MRI was performed in the 3rd and 7th days after blood injections. ICH were definitely identified in the first MRI scans. The MRI semiotics features of acute ICH and their transformations were assessed. The high sensitivity of MRI to ICH as well as the uniform manifestations in all animals were shown. In conclusion, the method has high specificity for acute ICH detection.

  5. MRI in psychiatry

    International Nuclear Information System (INIS)

    Mulert, Christoph; Shenton, Martha E.

    2014-01-01

    This is the first comprehensive textbook on the use of MRI in psychiatry covering imaging techniques, brain systems and a review of findings in different psychiatric disorders. The book is divided into three sections, the first of which covers in detail all the major MRI-based methodological approaches available today, including fMRI, EEG-fMRI, DTI, and MR spectroscopy. In addition, the role of MRI in imaging genetics and combined brain stimulation and imaging is carefully explained. The second section provides an overview of the different brain systems that are relevant for psychiatric disorders, including the systems for perception, emotion, cognition, and reward. The final part of the book presents the MRI findings that are obtained in all the major psychiatric disorders using the previously discussed techniques. Numerous carefully chosen images support the informative text, making this an ideal reference work for all practitioners and trainees with an interest in this flourishing field.

  6. MRI in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Mulert, Christoph [UKE, Hamburg (Germany). Psychiatry Neuroimaging Branch; Shenton, Martha E. (ed.) [Harvard Medical School, Boston, MA (United States). Dept. of Psychiatry and Radiology

    2014-07-01

    This is the first comprehensive textbook on the use of MRI in psychiatry covering imaging techniques, brain systems and a review of findings in different psychiatric disorders. The book is divided into three sections, the first of which covers in detail all the major MRI-based methodological approaches available today, including fMRI, EEG-fMRI, DTI, and MR spectroscopy. In addition, the role of MRI in imaging genetics and combined brain stimulation and imaging is carefully explained. The second section provides an overview of the different brain systems that are relevant for psychiatric disorders, including the systems for perception, emotion, cognition, and reward. The final part of the book presents the MRI findings that are obtained in all the major psychiatric disorders using the previously discussed techniques. Numerous carefully chosen images support the informative text, making this an ideal reference work for all practitioners and trainees with an interest in this flourishing field.

  7. Superconductive MRI system, FLEXARTTM

    International Nuclear Information System (INIS)

    Suzuki, Hirokazu; Nishikawa, Mineki; Goro, Takehiko

    1994-01-01

    Since the establishment of TAMI (Toshiba America MRI Inc.) in 1989, it has been jointly working with Toshiba on developing a new infrastructure for computer and software technologies to be applied to new MRI (magnetic resonance imaging) systems. As a result of these efforts, the first product of a new series of MRI systems has been introduced on the market. Known as FLEXART TM (a newly created word combining FLEXible and ART), this MRI system incorporates a new 32-bit RISC computer and a new controller for pulse sequences and data acquisition. The product concepts of FLEXART TM are high image quality, high patient throughput, and ease of use, all of which are necessary features for an MRI system in the premium mid-field MRI market segment. (author)

  8. Determination of picomolar silver concentrations by differential pulse anodic stripping voltammetry at a carbon paste electrode modified with phenylthiourea-functionalized high ordered nanoporous silica gel

    International Nuclear Information System (INIS)

    Javanbakht, Mehran; Divsar, Faten; Badiei, Alireza; Fatollahi, Fatemeh; Khaniani, Yeganeh; Ganjali, Mohammad Reza; Norouzi, Parviz; Chaloosi, Marzieh; Ziarani, Ghodsi Mohammadi

    2009-01-01

    This study introduces the design of an anodic stripping voltammetric (ASV) method for the silver ion determination at a carbon paste electrode (CPE), chemically modified with phenylthiourea-nanoporous silica gel (Tu-SBA-15-CPE). The electroanalytical pro includes two steps: preconcentration of metal ions at an electrode surface, followed by quantification of the accumulated species by differential pulse anodic stripping voltammetric methods. Factors affecting the performance of the anodic stripping were investigated, including the modifier quantity in the paste, the electrolyte concentrations, the solution pH and the accumulation potential or time. The most sensitive and reliable electrode contained 10% Tu-SBA-15 and 90% carbon paste. The accumulation potential and time were set at, -200 mV and 300 s, respectively, and the scan rate at 50 mV s -1 in the scan range of -200 to 700 mV. The resulting electrode demonstrated a linear response over range of silver ion concentration of 8.0-80 pmol/L with detection limit (S/N = 3) of 5 pmol/L. The prepared electrodes were used for the silver determination in sea and tap water samples and very good recovery results were obtained. The accuracy was assessed through recovery experiments and independent analysis by graphite furnace atomic absorption spectrometry.

  9. Determination of picomolar silver concentrations by differential pulse anodic stripping voltammetry at a carbon paste electrode modified with phenylthiourea-functionalized high ordered nanoporous silica gel

    Energy Technology Data Exchange (ETDEWEB)

    Javanbakht, Mehran [Department of Chemistry, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Nano Science and Technology Research Center, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of)], E-mail: mehranjavanbakht@gmail.com; Divsar, Faten [Department of Chemistry, University of Tarbiat Moallem, Tehran (Iran, Islamic Republic of); Badiei, Alireza [School of Chemistry, University College of Science, University of Tehran, Tehran (Iran, Islamic Republic of); Fatollahi, Fatemeh [Department of Chemistry, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Khaniani, Yeganeh [School of Chemistry, University College of Science, University of Tehran, Tehran (Iran, Islamic Republic of); Ganjali, Mohammad Reza; Norouzi, Parviz [Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran (Iran, Islamic Republic of); Chaloosi, Marzieh [Department of Chemistry, University of Tarbiat Moallem, Tehran (Iran, Islamic Republic of); Ziarani, Ghodsi Mohammadi [Department of Chemistry, University of Alzahra, Tehran (Iran, Islamic Republic of)

    2009-09-30

    This study introduces the design of an anodic stripping voltammetric (ASV) method for the silver ion determination at a carbon paste electrode (CPE), chemically modified with phenylthiourea-nanoporous silica gel (Tu-SBA-15-CPE). The electroanalytical pro includes two steps: preconcentration of metal ions at an electrode surface, followed by quantification of the accumulated species by differential pulse anodic stripping voltammetric methods. Factors affecting the performance of the anodic stripping were investigated, including the modifier quantity in the paste, the electrolyte concentrations, the solution pH and the accumulation potential or time. The most sensitive and reliable electrode contained 10% Tu-SBA-15 and 90% carbon paste. The accumulation potential and time were set at, -200 mV and 300 s, respectively, and the scan rate at 50 mV s{sup -1} in the scan range of -200 to 700 mV. The resulting electrode demonstrated a linear response over range of silver ion concentration of 8.0-80 pmol/L with detection limit (S/N = 3) of 5 pmol/L. The prepared electrodes were used for the silver determination in sea and tap water samples and very good recovery results were obtained. The accuracy was assessed through recovery experiments and independent analysis by graphite furnace atomic absorption spectrometry.

  10. MRI of meningioma

    International Nuclear Information System (INIS)

    Yamamoto, Yoshio; Hiraki, Yoshio; Kaji, Mitumasa

    1988-01-01

    MRI has gained a prominent position in the diagnosis of brain tumors. We examined 30 cases of meningiomas and distinguished their subtype according to the criteria of Rubinic histology. We discussed the MRI findings and compared then with X-CT findings so to their intensity, delination of tumors, whether accompanied by peripheral edema, and T 1 values. MRI delinated the tumors as well as CE-CT. No remarkable difference was found between the subtypes. (author)

  11. Advanced flow MRI: emerging techniques and applications

    International Nuclear Information System (INIS)

    Markl, M.; Schnell, S.; Wu, C.; Bollache, E.; Jarvis, K.; Barker, A.J.; Robinson, J.D.; Rigsby, C.K.

    2016-01-01

    Magnetic resonance imaging (MRI) techniques provide non-invasive and non-ionising methods for the highly accurate anatomical depiction of the heart and vessels throughout the cardiac cycle. In addition, the intrinsic sensitivity of MRI to motion offers the unique ability to acquire spatially registered blood flow simultaneously with the morphological data, within a single measurement. In clinical routine, flow MRI is typically accomplished using methods that resolve two spatial dimensions in individual planes and encode the time-resolved velocity in one principal direction, typically oriented perpendicular to the two-dimensional (2D) section. This review describes recently developed advanced MRI flow techniques, which allow for more comprehensive evaluation of blood flow characteristics, such as real-time flow imaging, 2D multiple-venc phase contrast MRI, four-dimensional (4D) flow MRI, quantification of complex haemodynamic properties, and highly accelerated flow imaging. Emerging techniques and novel applications are explored. In addition, applications of these new techniques for the improved evaluation of cardiovascular (aorta, pulmonary arteries, congenital heart disease, atrial fibrillation, coronary arteries) as well as cerebrovascular disease (intra-cranial arteries and veins) are presented.

  12. Low-Cost High-Performance MRI

    Science.gov (United States)

    Sarracanie, Mathieu; Lapierre, Cristen D.; Salameh, Najat; Waddington, David E. J.; Witzel, Thomas; Rosen, Matthew S.

    2015-10-01

    Magnetic Resonance Imaging (MRI) is unparalleled in its ability to visualize anatomical structure and function non-invasively with high spatial and temporal resolution. Yet to overcome the low sensitivity inherent in inductive detection of weakly polarized nuclear spins, the vast majority of clinical MRI scanners employ superconducting magnets producing very high magnetic fields. Commonly found at 1.5-3 tesla (T), these powerful magnets are massive and have very strict infrastructure demands that preclude operation in many environments. MRI scanners are costly to purchase, site, and maintain, with the purchase price approaching $1 M per tesla (T) of magnetic field. We present here a remarkably simple, non-cryogenic approach to high-performance human MRI at ultra-low magnetic field, whereby modern under-sampling strategies are combined with fully-refocused dynamic spin control using steady-state free precession techniques. At 6.5 mT (more than 450 times lower than clinical MRI scanners) we demonstrate (2.5 × 3.5 × 8.5) mm3 imaging resolution in the living human brain using a simple, open-geometry electromagnet, with 3D image acquisition over the entire brain in 6 minutes. We contend that these practical ultra-low magnetic field implementations of MRI (standards for affordable (<$50,000) and robust portable devices.

  13. Studies of MRI relaxivities of gadolinium-labeled dendrons

    Science.gov (United States)

    Pan, Hongmu; Daniel, Marie-Christine

    2011-05-01

    In cancer detection, imaging techniques have a great importance in early diagnosis. The more sensitive the imaging technique and the earlier the tumor can be detected. Contrast agents have the capability to increase the sensitivity in imaging techniques such as magnetic resonance imaging (MRI). Until now, gadolinium-based contrast agents are mainly used for MRI, and show good enhancement. But improvement is needed for detection of smaller tumors at the earliest stage possible. The dendrons complexed with Gd(DOTA) were synthesized and evaluated as a new MRI contrast agent. The longitudinal and transverse relaxation effects were tested and compared with commercial drug Magnevist, Gd(DTPA).

  14. MRI assessment program

    International Nuclear Information System (INIS)

    1988-05-01

    Usage, cost and efficacy data from the MRI Assessment Program to 30 March 1988 is presented, as a continuation of an earlier analysis. Analysis has been performed on data from 8565 examinations relating to 7997 patients at 4 hospitals. MRI was used mainly for examination of the head and spine. Some details of the follow up studies being conducted on selected patients and disease categories are given. A consensus statement is included which summaries the view of the Technical Committee on the potential applications of MRI in Australia. The MRI unit quench incident at Royal Adelaide Hospital is described. Refs., 10 figs., tabs

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or patients with claustrophobia. Other MRI machines are open on the sides (open MRI). Open units are especially helpful for examining larger patients or those with claustrophobia. Newer open MRI units provide very high quality images for ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... does not completely surround you. Some newer MRI machines have a larger diameter bore which can be ... size patients or patients with claustrophobia. Other MRI machines are open on the sides (open MRI). Open ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... in the first three to four months of pregnancy unless the potential benefit from the MRI exam ... the MRI Safety page for more information about pregnancy and MRI. If you have claustrophobia (fear of ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... information on the chemicals present in the body's cells, may also be performed during the MRI exam ... medically necessary. MRI may not always distinguish between cancer tissue and fluid, known as edema . MRI typically ...

  19. MRI in sarcoglycanopathies

    DEFF Research Database (Denmark)

    Tasca, Giorgio; Monforte, Mauro; Díaz-Manera, Jordi

    2018-01-01

    OBJECTIVES: To characterise the pattern and spectrum of involvement on muscle MRI in a large cohort of patients with sarcoglycanopathies, which are limb-girdle muscular dystrophies (LGMD2C-2F) caused by mutations in one of the four genes coding for muscle sarcoglycans. METHODS: Lower limb MRI sca...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician ... absolutely necessary for medical treatment. See the MRI Safety page for more information about pregnancy and MRI. ...

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... internal body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to evaluate various ... seen by other imaging modalities, such as chest x-ray or CT. A special form of MRI called ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... fitting and has no metal fasteners. Guidelines about eating and drinking before an MRI exam vary with the specific exam and with the imaging facility. Unless you are told otherwise, you may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. People with the ...

  5. MRI of neonatal encephalopathy

    International Nuclear Information System (INIS)

    Khong, P.L.; Lam, B.C.C.; Tung, H.K.S.; Wong, V.; Chan, F.L.; Ooi, G.C.

    2003-01-01

    We present the magnetic resonance imaging (MRI) findings in neonatal encephalopathy, including hypoxic-ischaemic encephalopathy, perinatal/neonatal stroke, metabolic encephalopathy from inborn errors of metabolism, congenital central nervous system infections and birth trauma. The applications of advanced MRI techniques, such as diffusion-weighted imaging and magnetic resonance spectroscopy are emphasized

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to evaluate various ... seen by other imaging modalities, such as chest x-ray or CT. A special form of MRI called ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... structure of an organ and how it is working. MRI enables the discovery of abnormalities that might be obscured by bone with other imaging methods. The contrast material used in MRI exams is less likely to produce an allergic reaction than the ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... computer to produce detailed pictures of organs, soft tissues, bone and virtually all other internal body structures. MRI ... cancer, heart and vascular disease, heart valve abnormalities, bone and other soft tissue abnormalities of the chest. MRI is also useful ...

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... other internal body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to ... computed tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms that ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... absolutely necessary for medical treatment. See the MRI Safety page for more information about pregnancy and MRI. ...

  11. MRI of meniscal bucket-handle tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, T.H.; Hinson, G.W. [Menorah Medical Center, Overland Park, KS (United States). Dept. of Radiology

    1998-09-01

    A meniscal bucket-handle tear is a tear with an attached fragment displaced from the meniscus of the knee joint. Low sensitivity of MRI for detection of bucket-handle tears (64% as compared with arthroscopy) has been reported previously. We report increased sensitivity for detecting bucket-handle tears with the use of coronal short tau inversion recovery (STIR) images. Results. By using four criteria for diagnosis of meniscal bucket-handle tears, our overall sensitivity compared with arthroscopy was 93% (28 of 30 meniscal bucket-handle tears seen at arthroscopy were detected by MRI). The meniscal fragment was well visualized in all 28 cases on coronal STIR images. The double posterior cruciate ligament sign was seen in 8 of 30 cases, the flipped meniscus was seen in 10 of 30 cases and a fragment in the intercondylar notch was seen in 18 of 30 cases. (orig.)

  12. Mobius syndrome: MRI features

    International Nuclear Information System (INIS)

    Markarian, Maria F.; Villarroel, Gonzalo M.; Nagel, Jorge R.

    2003-01-01

    Purpose: Mobius Syndrome or congenital facial diplegia is associated with paralysis of the lateral gaze movements. This syndrome may include other cranial nerve palsies and be associated to musculoskeletal anomalies. Our objective is to show the MRI findings in Mobius Syndrome. Material and methods: MRI study was performed in 3 patients with clinic diagnosis of Mobius Syndrome. RMI (1.5T); exams included axial FSE (T1 and T2), FLAIR, SE/EPI, GRE/20, sagittal FSE T2 , coronal T1, diffusion, angio MRI and Spectroscopy sequences. Results: The common features of this syndrome found in MRI were: depression or straightening of the floor of the fourth ventricle, brainstem anteroposterior diameter diminution, morphologic alteration of the pons and medulla oblongata and of the hypoglossal nuclei as well as severe micrognathia. Conclusion: The morphologic alterations of Mobius Syndrome can be clearly identified by MRI; this method has proved to be a useful diagnostic examination. (author)

  13. Application of functional MRI in breast diseases

    International Nuclear Information System (INIS)

    Feng Yun; Liu Shiyuan; Wang Chenguang; Tao Xiaofeng; Wang Jinlin; Wang Jian

    2007-01-01

    Objective: To investigate the value of functional MRI in the diagnosis and differential diagnosis of breast diseases. Methods: Sixty-five patients with 68 lesions were enrolled in this study. Conventional T 1 WI and T 2 WI scan, dynamic contrast enhanced MRI, diffusion weighted imaging and 1 H single voxel MR spectroscopy were performed consequently. All lesions were verified by pathology, including 4 cases of breast adenosis, 22 fibroadenomas, 2 chronic inflammations, 3 cysts, 33 infitrating ductal carcinomas, 1 intraductal carcinoma and 3 cystosarcoma phyllodes tumors. Morphological features, maximum enhancement ratio, time-intensity curve, apparent diffusion coefficient and Choline peak were analyzed. Results: The detection rates of T 1 WI and T 2 WI were 14.7% (n=10) and 51.5% (n=35). The sensitivity, specificity, accuracy of dynamic contrast enhanced MRI for the malignant tumor were 94. 6%, 71.4% and 76.5% respectively. Retrospective study showed that diffusion weighted imaging, with the b value from 800 s/mm 2 to 1000 s/mm 2 , could be used to differentiate various types of breast lesions. 1 H signal voxel spectroscopy had a sensitivity of 51.4%, specificity of 82.6%, and accuracy of 67.6% for the malignent. The sensitivity, specificity and accuracy could reach 97.3%, 90.0% and 92.6% respectively by combining conventional scan, dynamic contrast enhanced MRI and MR spectroscopy. Conclusion: Functional MRI, with high sensitivity, specificity and accuracy, can be used widely in the diagnosis of malignant breast lesions. (authors)

  14. Value of functional MRI in evaluation of patients with suspected prostate cancer

    Directory of Open Access Journals (Sweden)

    Mostafa Mohamed Mostafa Elian

    2015-12-01

    Conclusion: Functional MRI provided a highly sensitive method in diagnosing and localizing prostate cancer. Being noninvasive, highly sensitive with wider spectrum in nearby pelvic organs assessment in one imaging session, it may totally replace TRUS-guided biopsy.

  15. Rapid and sensitive detection of synthetic cannabinoids AMB-FUBINACA and α-PVP using surface enhanced Raman scattering (SERS)

    Science.gov (United States)

    Islam, Syed K.; Cheng, Yin Pak; Birke, Ronald L.; Green, Omar; Kubic, Thomas; Lombardi, John R.

    2018-04-01

    The application of surface enhanced Raman scattering (SERS) has been reported as a fast and sensitive analytical method in the trace detection of the two most commonly known synthetic cannabinoids AMB-FUBINACA and alpha-pyrrolidinovalerophenone (α-PVP). FUBINACA and α-PVP are two of the most dangerous synthetic cannabinoids which have been reported to cause numerous deaths in the United States. While instruments such as GC-MS, LC-MS have been traditionally recognized as analytical tools for the detection of these synthetic drugs, SERS has been recently gaining ground in the analysis of these synthetic drugs due to its sensitivity in trace analysis and its effectiveness as a rapid method of detection. This present study shows the limit of detection of a concentration as low as picomolar for AMB-FUBINACA while for α-PVP, the limit of detection is in nanomolar concentration using SERS.

  16. MRI features of tuberculosis of peripheral joints

    Energy Technology Data Exchange (ETDEWEB)

    Sawlani, V.; Chandra, T.; Mishra, R.N.; Aggarwal, A.; Jain, U.K.; Gujral, R.B. E-mail: gujralrb@sgpgi.ac.in

    2003-10-01

    The aim of this article is to present the magnetic resonance imaging (MRI) features of peripheral tubercular arthritis. The clinical presentation of peripheral tubercular arthritis is variable and simulates other chronic inflammatory arthritic disorders. MRI is a highly sensitive technique which demonstrates fine anatomical details and identifies the early changes of arthritis, which are not visible on radiographs. The MRI features of tubercular arthritis include synovitis, effusion, central and peripheral erosions, active and chronic pannus, abscess, bone chips and hypo-intense synovium. These imaging features in an appropriate clinical setting may help in the diagnosis of tubercular arthritis. Early diagnosis and treatment can effectively eliminate the long-term morbidity of joints affected by tuberculosis.

  17. MRI features of tuberculosis of peripheral joints

    International Nuclear Information System (INIS)

    Sawlani, V.; Chandra, T.; Mishra, R.N.; Aggarwal, A.; Jain, U.K.; Gujral, R.B.

    2003-01-01

    The aim of this article is to present the magnetic resonance imaging (MRI) features of peripheral tubercular arthritis. The clinical presentation of peripheral tubercular arthritis is variable and simulates other chronic inflammatory arthritic disorders. MRI is a highly sensitive technique which demonstrates fine anatomical details and identifies the early changes of arthritis, which are not visible on radiographs. The MRI features of tubercular arthritis include synovitis, effusion, central and peripheral erosions, active and chronic pannus, abscess, bone chips and hypo-intense synovium. These imaging features in an appropriate clinical setting may help in the diagnosis of tubercular arthritis. Early diagnosis and treatment can effectively eliminate the long-term morbidity of joints affected by tuberculosis

  18. Cerebral activity mapped by functional MRI

    International Nuclear Information System (INIS)

    Bruening, R.; Danek, A.; Wu, R.H.; Berchtenbreiter, C.; Reiser, M.

    1997-01-01

    Functional magnetic resonance imaging (fMRI) is a method to noninvasively measure the changes in cerebral activation during sensitive, cognitive or motor activity. fMRI detects activity by subtraction of states of activity and rest. During activity the signal is increased presumably due to a decrease of deoxyhemoglobin in the capillary and venous structures. Using a full field visual stimulation by flashlight goggles, a signal increase of 3% was detected in the primary visual cortex (V1). Different sequences and postprocessing algorythms will be discussed. Data from the primary cortical areas suggest a high reproducability of the experiments. Successfull experiments highly depend on cooperation of subjects. Despite success in experiments fMRI still has to be established for clinical purposes. (orig.) [de

  19. Dynamic MRI study for breast tumors

    International Nuclear Information System (INIS)

    Seki, Tsuneaki

    1990-01-01

    Application of MRI for diagnosis of breast tumors was retrospectively examined in 103 consecutive cases. Contrast enhancement, mostly by dynamic study, was performed in 83 cases using Gd-DTPA and 0.5 T superconductive apparatus. Results were compared to those of mammography and sonography. On dynamic study, carcinoma showed abrupt rise of signal intensity with clear-cut peak formation in early phase, while benign fibroadenoma showed slow rise of signal intensity and prolonged enhancement without peak formation. In 12 of 33 carcinomas (33%), peripheral ring enhancement was noted reflecting vascular stroma of histologic sections. All fibroadenomas showed homogenous enhancement without peripheral ring. In MRI, sensitivity, specificity, and accuracy were 86%, 96%, 91%. In mammography 82%, 95%, 87% and in ultrasonography 91%, 95%, 93%. Although MRI should not be regarded as routine diagnostic procedure because of expense and limited availability, it may afford useful additional information when standard mammographic findings are not conclusive. (author)

  20. Indications for body MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dujardin, M. [Department of Radiology, Vrije Universiteit Brussel, BEFY, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: martine.dujardin@gmail.com; Vandenbroucke, F. [Department of Radiology, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: frederik.vandenbroucke@az.vub.ac.be; Boulet, C. [Department of Radiology, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: cedric.boulet@az.vub.ac.be; Op de Beeck, B. [Department of Radiology, UZA and Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: bart.op.de.beeck@uza.be; Mey, J. de [Department of Radiology, Vrije Universiteit Brussel, BEFY, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: johan.demey@az.vub.ac.be

    2008-02-15

    The lack of ionizing radiation use in MRI makes the high spatial resolution technique very appealing. Also, the easy access to multiplanar imaging and the fact that gadolinium-DTPA is well tolerated and not nephrotoxic makes MRI a robust alternative in the healthy as well as the renal compromised patient. Furthermore, MRI adds advanced possibility for tissue characterization and pathology detection and dynamic imaging can be performed. Specific contrast agents specific to the hepatobiliary or the reticuloendothelial system can help with additional information in problem cases. The role of MRI for different organs is discussed and a review of the literature is given. We concluded that MRI is considered a useful and non-invasive diagnostic tool for the detection of hepatic iron concentration, to correct misdiagnosis (pseudolesions) from US and CT in focal steatosis and to help with focal lesion detection and characterization, in the healthy and especially in the cirrhotic liver, where MRI is superior to CT. Moreover, MRCP is excellent for identifying the presence and the level of biliary obstruction in malignant invasion and is considered in the literature as a non-invasive screening tool for common bile duct stones, appropriately selecting candidates for preoperative ERCP and sparing others the need for an endoscopic procedure with its associated complications. MRI is the first choice modality for adrenal evaluation in contemporary medical imaging. It is a useful examination in renal as well as splenic pathology and best assesses loco-regional staging, i.e. arterial involvement in pancreatic cancer.

  1. Diagnosis and heterogeneity of MS in MRI

    International Nuclear Information System (INIS)

    Holst, B.; Fiehler, J.; Schippling, S.

    2008-01-01

    An efficient therapy of MS requires a quick and reliable diagnosis of the disease. MRI is the most leading paraclinical examination for MS diagnosis. Even though there is no pathognomic finding in MRI, there are MS characteristics with respect to morphology and localization. To exclude other neurological disorders and distinguish between different characteristics within MS, the use of contrast agent is advantageous. Postulated MRI criteria have been increasingly adjusted to the clinical routine and have become clearer, more sensitive, and more specific. Different imaging criteria will be introduced. In addition to the McDonald criteria of 2001 and 2005, new criteria will be presented in which the use of contrast agent is replaced by a second MRI and the dissemination in time and space is simplified. Different pathomechanisms which help to separate MS patients into subgroups are postulated. The diverse pathomechanisms also enable the development of new pharmaceuticals to manipulate the immunologic course in different stages. For varying therapy approaches, it is increasingly important to differentiate the heterogeneous appearance forms into subtypes. The two visible main components of the disorder in MRI are inflammation and neurodegeneration and are responsible for different clinical courses. Both are interdependent and independent of each other. We introduce a stratification which uses both components as a function of their different outcomes to compose subgroups. The previous challenge with respect to MRI was to support the diagnosis of MS via MRI criteria. A future problem will be the heterogeneity and classification of subgroups. This article gives an overview of both problems. (orig.)

  2. Diagnostic accuracy and patient acceptance of MRI in children with suspected appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Mai E.; Valdehueza, Zaldy D.; Wiarda, Bart M. [Medical Centre Alkmaar, Department of Radiology, Alkmaar (Netherlands); Leeuwenburgh, Marjolein M.N. [Academic Medical Centre Amsterdam, Department of Radiology, Amsterdam (Netherlands); Academic Medical Centre Amsterdam, Department of Surgery, Amsterdam (Netherlands); Bouman, Donald E. [Medical Spectrum Twente, Department of Radiology, Enschede (Netherlands); Bruin, Ivar G.J.M. de; Schreurs, W.H.; Houdijk, Alexander P.J. [Medical Centre Alkmaar, Department of Surgery, Alkmaar (Netherlands); Stoker, Jaap [Academic Medical Centre Amsterdam, Department of Radiology, Amsterdam (Netherlands)

    2014-03-15

    To compare magnetic resonance imaging (MRI) and ultrasound in children with suspected appendicitis. In a single-centre diagnostic accuracy study, children with suspected appendicitis were prospectively identified at the emergency department. All underwent abdominal ultrasound and MRI within 2 h, with the reader blinded to other imaging findings. An expert panel established the final diagnosis after 3 months. We evaluated the diagnostic accuracy of three imaging strategies: ultrasound only, conditional MRI after negative or inconclusive ultrasound, and MRI only. Significance between sensitivity and specificity was calculated using McNemar's test statistic. Between April and December 2009 we included 104 consecutive children (47 male, mean age 12). According to the expert panel, 58 patients had appendicitis. The sensitivity of MRI only and conditional MRI was 100 % (95 % confidence interval 92-100), that of ultrasound was significantly lower (76 %; 63-85, P < 0.001). Specificity was comparable among the three investigated strategies; ultrasound only 89 % (77-95), conditional MRI 80 % (67-89), MRI only 89 % (77-95) (P values 0.13, 0.13 and 1.00). In children with suspected appendicitis, strategies with MRI (MRI only, conditional MRI) had a higher sensitivity for appendicitis compared with a strategy with ultrasound only, while specificity was comparable. (orig.)

  3. Explaining MRI examinations DVD

    International Nuclear Information System (INIS)

    Takatsu, Yasuo; Komeda, Takuya

    2010-01-01

    When conducting MRI examinations, there are various things to be careful of. There is often stress related to the MRI examinations, so in order to perform an examination safely and smoothly, sufficient explanation must be given. An explanation of what to do and what not to do during an examination should be outlined in a brochure given to patients before the examination. There may be many patients who have misgivings about their MRI examinations, so to reduce their anxiousness and deepen their understanding of MRI examinations and to improve the safety and effiency of MRI examinations,; we created a DVD about MRI examinations. We gathered MRI-related safety information and instructions, and assessed the effect that the information might have on patients. We started a workgroup for a project to plan and record a video according to the Storyboard. When editing, we reviewed the length of each segment, the amount of information on screen, and the overall length of the DVD. We discussed the issue within the workgroup and had hospital approval. It was possible for us to complete it without depending on the supplier and the cost was kept to a minimum. Finally, we decided on a viewing location. We asked a hospital volunteers to see a complete DVD and we evaluated their responses by questionnaires. As the result, their understanding and anxieties related to MRI examinations were alleviated, as expected. Their anxiety seemed to be eased. Patients also seemed to have a deeper understanding of MRI examinations having seen an examination being conducted. (author)

  4. MRI of 'brain death'

    International Nuclear Information System (INIS)

    Nishino, Shigeki; Itoh, Takahiko; Tuchida, Shohei; Kinugasa, Kazushi; Asari, Shoji; Nishimoto, Akira; Sanou, Kazuo.

    1990-01-01

    Magnetic resonance imaging (MRI) was undertaken for two patients who suffered from severe cerebrovascular diseases and were clinically brain dead. The MRI system we used was Resona (Yokogawa Medical Systems, superconductive system 0.5 T) and the CT apparatus was Toshiba TCT-300. Initial CT and MRI were undertaken as soon as possible after admission, and repeated sequentially. After diagnosis of brain death, we performed angiography to determine cerebral circulatory arrest, and MRI obtained at the same time was compared with the angiogram and CT. Case 1 was a 77-year-old man who was admitted in an unconscious state. CT and MRI on the second day after hospitalization revealed cerebellar infarction. He was diagnosed as brain dead on day 4. Case 2 was a 35-year-old man. When he was transferred to our hospital, he was in cardiorespiratory arrested. Cardiac resuscitation was successful but no spontaneous respiration appeared. CT and MRI on admission revealed right intracerebral hemorrhage. Angiography revealed cessation of contrast medium in intracranial vessels in both of the patients. We found no 'flow signal void sign' in the bilateral internal carotid and basilar arteries on MRI images in both cases after brain death. MRI, showing us the anatomical changes of the brain, clearly revealed brain herniations, even though only nuclear findings of 'brain tamponade' were seen on CT. But in Case 1, we could not see the infarct lesions in the cerebellum on MR images obtained after brain death. This phenomenon was caused by the whole brain ischemia masking the initial ischemic lesions. We concluded that MRI was useful not only the anatomical display of lesions and brain herniation with high contrast resolution but for obtaining information on cerebral circulation of brain death. (author)

  5. [Determination of joint contact area using MRI].

    Science.gov (United States)

    Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji

    2009-10-20

    Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo.

  6. Determination of joint contact area using MRI

    International Nuclear Information System (INIS)

    Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji

    2009-01-01

    Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo. (author)

  7. Prenatal MRI in correlation with ultrasound

    International Nuclear Information System (INIS)

    Balev, B.; Baleva, D.; Ivanova, D.; Popova, R.

    2012-01-01

    Full text: Fetal MRI is an already established method in prenatal imaging, with complementary to US role. Most common considerations for fetal MRI are CNS anomalies and urogenital anomalies. Practically, the most frequent indication is ultrasonographically established ventriculomegaly. We introduce our experience in fetal MRI, presenting the distribution of pathological findings and our protocols. We have examined 33 fetuses for a 3-year period. Among these 13 cases were affected by CNS anomalies (neural tube defects, Dandy-Walker, cerebellar hypoplasia, agenesis of corpus callosum, aqueductal atresia, etc.), 11 fetuses are affected by urogenital anomalies (pieloureteral stenosis, VUR, renal agenesis, etc.), 5 with other pathology (congenital tumor, ovarian cysts, etc.) and 4 are normal fetuses. The findings in most interesting cases are reviewed; in some of them we present imaging-pathological correlation and/or follow up imaging. Main advantages of fetal MRI over US consist of acquiring objective and reproducible images, giving the opportunity of multiple expert-leveled reviews; exceptionally high detail concerning CNS-anatomy; additional confidence in excluding presence of concomitant anomalies; independence from calavarial ossification and maternal obesity. Ultrasound remains the main tool for prenatal imaging. MRI has similar sensitivity and higher specificity, thus serving as an arbitrage method and improving accuracy about outcome prognosis

  8. Quantitative rotating frame relaxometry methods in MRI.

    Science.gov (United States)

    Gilani, Irtiza Ali; Sepponen, Raimo

    2016-06-01

    Macromolecular degeneration and biochemical changes in tissue can be quantified using rotating frame relaxometry in MRI. It has been shown in several studies that the rotating frame longitudinal relaxation rate constant (R1ρ ) and the rotating frame transverse relaxation rate constant (R2ρ ) are sensitive biomarkers of phenomena at the cellular level. In this comprehensive review, existing MRI methods for probing the biophysical mechanisms that affect the rotating frame relaxation rates of the tissue (i.e. R1ρ and R2ρ ) are presented. Long acquisition times and high radiofrequency (RF) energy deposition into tissue during the process of spin-locking in rotating frame relaxometry are the major barriers to the establishment of these relaxation contrasts at high magnetic fields. Therefore, clinical applications of R1ρ and R2ρ MRI using on- or off-resonance RF excitation methods remain challenging. Accordingly, this review describes the theoretical and experimental approaches to the design of hard RF pulse cluster- and adiabatic RF pulse-based excitation schemes for accurate and precise measurements of R1ρ and R2ρ . The merits and drawbacks of different MRI acquisition strategies for quantitative relaxation rate measurement in the rotating frame regime are reviewed. In addition, this review summarizes current clinical applications of rotating frame MRI sequences. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  11. Strategies for sensing neurotransmitters with responsive MRI contrast agents.

    Science.gov (United States)

    Angelovski, Goran; Tóth, Éva

    2017-01-23

    A great deal of research involving multidisciplinary approaches is currently dedicated to the understanding of brain function. The complexity of physiological processes that underlie neural activity is the greatest hurdle to faster advances. Among imaging techniques, MRI has great potential to enable mapping of neural events with excellent specificity, spatiotemporal resolution and unlimited tissue penetration depth. To this end, molecular imaging approaches using neurotransmitter-sensitive MRI agents have appeared recently to study neuronal activity, along with the first successful in vivo MRI studies. Here, we review the pioneering steps in the development of molecular MRI methods that could allow functional imaging of the brain by sensing the neurotransmitter activity directly. We provide a brief overview of other imaging and analytical methods to detect neurotransmitter activity, and describe the approaches to sense neurotransmitters by means of molecular MRI agents. Based on these initial steps, further progress in probe chemistry and the emergence of innovative imaging methods to directly monitor neurotransmitters can be envisaged.

  12. Management of breast lesions detectable only on MRI

    International Nuclear Information System (INIS)

    Siegmann-Luz, K.C.; Bahrs, S.D.; Preibsch, H.; Hattermann, V.; Claussen, C.D.

    2014-01-01

    Breast MR imaging has become established as the most sensitive imaging method for diagnosing breast cancer. As a result of the increasing examination volume and improved image quality, the number of breast lesions detected only on MRI and requiring further clarification has risen in recent years. According to the S3-guideline 'Diagnosis, Therapy, and Follow-Up of Breast Cancer' as revised in July 2012, institutions performing breast MRI should provide the option of an MRI-guided intervention for clarification. This review describes the indications, methods and results of MRI-guided interventions for the clarification of breast lesions only visible on MRI. Recent guidelines and study results are also addressed and alternative methods and pitfalls are presented. (orig.)

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... has any questions. Some implanted devices require a short period of time after placement (usually six weeks) ... center of the magnet. Some MRI units, called short-bore systems , are designed so that the magnet ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... any recent surgeries. Some conditions, such as severe kidney disease, may prevent you from being given gadolinium contrast ... an MRI. If you have a history of kidney disease or liver transplant, it will be necessary to ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... told otherwise, take your regular medications as usual. Leave jewelry at home and wear loose, comfortable clothing. ... contrast material except when absolutely necessary for medical treatment. See the MRI Safety page for more information ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... told otherwise, take your regular medications as usual. Leave jewelry at home and wear loose, comfortable clothing. ... contrast material except when absolutely necessary for medical treatment. See the MRI ... pocket knives and eyeglasses body piercings ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... imaging modalities (typically CT) or which are particularly well-suited to MR imaging. determine tumor size, extent, ... the exam. MRI scanners are air-conditioned and well-lit. Music may be played through the headphones ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... and send a signed report to your primary care or referring physician, who will share the results ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ... abnormalities where Chest CT is a preferred imaging test. MR imaging can assess blood flow without risking ...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms that naturally exist ... thumping sounds when the coils that generate the radiofrequency pulses are activated. Some centers provide earplugs, while ...

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has proven valuable in diagnosing a broad range of conditions, including cancer, heart and vascular disease, heart valve abnormalities, bone and other soft tissue ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... Infants and young children usually require sedation or anesthesia to complete an MRI exam without moving. Whether ... A physician or nurse specializing in sedation or anesthesia for children should be available during the exam ...

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... it may cause some medical devices to malfunction. Most orthopedic implants pose no risk, but you should ... or if you have asthma. The contrast material most commonly used for an MRI exam contains a ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... six weeks) before being safe for MRI examinations. Examples include but are not limited to: artificial heart ... usually completed within one hour but may occasionally take longer. top of page What will I experience ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... devices or metal in your body. Guidelines about eating and drinking before your exam vary between facilities. ... fitting and has no metal fasteners. Guidelines about eating and drinking before an MRI exam vary with ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. MRI of the chest gives detailed pictures ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... three to four months of pregnancy unless the potential benefit from the MRI exam is assumed to outweigh the potential risks. Pregnant women should not receive injections of ...

  9. MRI features of chondroblastoma

    International Nuclear Information System (INIS)

    Cheng Xiaoguang; Liu Xia; Cheng Kebin; Liu Wei

    2009-01-01

    Objective: To evaluate the MR imaging features of chondroblastoma. Methods: MRI examinations of 20 patients with histological proven chondmblastoma were reviewed retrospectively. The MRI findings of chondroblastoma including the signal intensity, the shape, the growth patterns, and the surrounding bone marrow edema and the adjacent soft tissue edema, the periosteal reaction, the adjacent joint effusion were analyzed. Results: All 20 cases demonstrated heterogeneous MR signal intensity on T 1 WI and T 2 WI images and showed lobular margins. Sixteen cases demonstrated expansive growth patterns. Surrounding bone marrow edema was found in 18 cases and adjacent soft tissue edema in 14 cases. Periosteal reaction was identified in 6 cases. In 7 cases the tumor extended to adjacent soft tissue. Adjacent joint effusion was visible on MRI in 6 cases. Conclusion: Heterogeneous signal intensity, lobular margins and expansive growth pattern, adjacent bone marrow and soft tissue edema were the common features of chondroblastoma on MRI. (authors)

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... also provides movie-like sequential imaging of the cardiovascular system that is important to assess the health ... invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has proven valuable in diagnosing a ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... prior obstruction of blood flow). determine blood flow dynamics in the vessels and heart chambers. display lymph ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... an MRI scan, but this is rare. Tooth fillings and braces usually are not affected by the magnetic field, but they may distort images of the facial area or brain, so you should let the ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Chest? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... a CD or uploaded to a digital cloud server. MRI of the chest gives detailed pictures of ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... traditional MRI unit is a large cylinder-shaped tube surrounded by a circular magnet. You will lie ... your skin at the site of the IV tube insertion. Some patients may sense a temporary metallic ...

  16. MRI of the Breast

    Science.gov (United States)

    ... in evaluating women at high risk for breast cancer. MRI can successfully image the dense breast tissue common in younger women, and it can successfully image breast implants. Both of these are difficult to image using ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... metal in your body. Guidelines about eating and drinking before your exam vary between facilities. Unless you ... has no metal fasteners. Guidelines about eating and drinking before an MRI exam vary with the specific ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI examinations may require you to receive an injection of contrast material into the bloodstream. The radiologist , ... the potential risks. Pregnant women should not receive injections of gadolinium contrast material except when absolutely necessary ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... will be removed. MRI exams generally include multiple runs (sequences), some of which may last several minutes. ... top of page Who interprets the results and how do I get them? A radiologist, a physician ...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... others nearby harm. These items include: jewelry, watches, credit cards and hearing aids, all of which can ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ...

  1. Arm MRI scan

    Science.gov (United States)

    ... MRI and ultrasound. In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. Grainger & Allison's Diagnostic ... Magnetic resonance imaging: In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. Grainger & Allison's Diagnostic ...

  2. Sinus MRI scan

    Science.gov (United States)

    ... CT, and MRI. In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. Grainger & Allison's Diagnostic ... Magnetic resonance imaging. In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. Grainger & Allison's Diagnostic ...

  3. Leg MRI scan

    Science.gov (United States)

    ... MRI and ultrasound. In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. Grainger & Allison's Diagnostic ... Magnetic resonance imaging: In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. Grainger & Allison's Diagnostic ...

  4. Knee MRI scan

    Science.gov (United States)

    ... MRI and ultrasound. In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. Grainger & Allison's Diagnostic ... Magnetic resonance imaging. In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. Grainger & Allison's Diagnostic ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... provides movie-like sequential imaging of the cardiovascular system that is important to assess the health and ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... you should let the radiologist know about them. Parents or family members who accompany patients into the ... intercom. Many MRI centers allow a friend or parent to stay in the room as long as ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... to produce detailed pictures of organs, soft tissues, bone and virtually all other internal body structures. MRI ... of the chest. assess disorders of the chest bones (vertebrae, ribs and sternum) and chest wall soft ...

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... Thus, the child remains motionless allowing for good quality images. Jewelry and other accessories should be left ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... will hear and feel loud tapping or thumping sounds when the coils that generate the radiofrequency pulses ... use headphones to reduce the intensity of the sounds made by the MRI machine. You may be ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... food, or the environment, or if you have asthma. The contrast material most commonly used for an ... Infants and young children usually require sedation or anesthesia to complete an MRI exam without moving. Whether ...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... are not limited to: artificial heart valves implanted drug infusion ports artificial limbs or metallic joint prostheses ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... take food and medications as usual. Some MRI examinations may require you to receive an injection of ... for a mild sedative prior to your scheduled examination. Infants and young children usually require sedation or ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. ... signals that are detected by the coils. The electric current does not come in contact with the ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... have any devices or metal in your body. Guidelines about eating and drinking before your exam vary ... is loose-fitting and has no metal fasteners. Guidelines about eating and drinking before an MRI exam ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... Most MRI exams are painless. However, some patients find it uncomfortable to remain still during MR imaging. ... anxious, confused or in severe pain, you may find it difficult to lie still during imaging. A ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging ( ... patient to have an allergy to a gadolinium-based contrast agent used for MRI than the iodine- ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... procedure performed? MRI examinations may be performed on outpatients or inpatients. You will be positioned on the ... and send a signed report to your primary care or referring physician, who will share the results ...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... used in tattoos may contain iron and could heat up during an MRI scan, but this is ... injection. If you do not require sedation, no recovery period is necessary. You may resume your usual ...

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... prior to your scheduled examination. Infants and young children usually require sedation or anesthesia to complete an MRI exam without moving. Whether a child requires sedation depends on the child's age, intellectual ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI exam, a physician, nurse or technologist will insert an intravenous (IV) catheter, also known as an ... physicians with expertise in several radiologic areas. Outside links: For the convenience of our users, RadiologyInfo .org ...

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... used in tattoos may contain iron and could heat up during an MRI scan, but this is ... a preferred imaging test. MR imaging can assess blood flow without risking the side effects of conventional ( ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance Imaging (MRI) Safety ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... you have any devices or metal in your body. Guidelines about eating and drinking before your exam ... soft tissues, bone and virtually all other internal body structures. MRI does not use ionizing radiation (x- ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... usual. Some MRI examinations may require you to receive an injection of contrast material into the bloodstream. ... outweigh the potential risks. Pregnant women should not receive injections of gadolinium contrast material except when absolutely ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI) of the chest uses a powerful magnetic field, radio waves and a computer to produce detailed ... there’s a possibility you are pregnant. The magnetic field is not harmful, but it may cause some ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table ...

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... allergies and whether there’s a possibility you are pregnant. The magnetic field is not harmful, but it ... if there is any possibility that they are pregnant. MRI has been used for scanning patients since ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... vessels, from almost any angle. MRI also provides movie-like sequential imaging of the cardiovascular system that ... headsets so that the child can watch a movie while the scan is being performed. Thus, the ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... to assess the anatomy and function of the heart and its blood flow. Tell your doctor about ... chest cavity, including the mediastinum , chest wall, pleura, heart and vessels, from almost any angle. MRI also ...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... and how it is working. MRI enables the discovery of abnormalities that might be obscured by bone ... Radiology (ACR) and the Radiological Society of North America (RSNA), comprising physicians with expertise in several radiologic ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the scheduler before the exam and bring ... patient for magnetic resonance imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help you pass the time. In some cases, intravenous injection of contrast material ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI) exam. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... and send a signed report to your primary care or referring physician, who will share the results ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... may have. top of page What does the equipment look like? The traditional MRI unit is a ... traction devices and many types of life support equipment may distort the MR images and as a ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... food, or the environment, or if you have asthma. The contrast material most commonly used for an ... complete an MRI exam without moving. Whether a child requires sedation depends on the child's age, intellectual ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... copied to a CD or uploaded to a digital cloud server. MRI of the chest gives detailed ... sedative prior to your scheduled examination. Infants and young children usually require sedation or anesthesia to complete ...

  1. VISARTTM superconducting MRI system

    International Nuclear Information System (INIS)

    Usui, Yoshiyuki; Goro, Takehiko; Yamagata, Hitoshi.

    1995-01-01

    We have developed VISART TM , a 1.5 T high-field magnetic resonance imaging (MRI) system based on technology developed for both the FLEXART TM (0.5T) and MRT-200/GP (1.5T) systems as the first and second products, respectively, of a new series of MRI systems. VISART TM is a newly coined word combining VISion and state-of-the-ART. A higher power gradient system and new high-speed imaging techniques have been developed to meet the market demand for higher resolution images and shorter scan times. The product concepts of VISART TM are high image quality, high patient throughput, flexible clinical application, and ease of use, all of which are essential features for an MRI system in the high-field MRI market segment. (author)

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ... to iodine or x-ray contrast material, drugs, food, or the environment, or if you have asthma. ...

  3. Studying neuroanatomy using MRI.

    Science.gov (United States)

    Lerch, Jason P; van der Kouwe, André J W; Raznahan, Armin; Paus, Tomáš; Johansen-Berg, Heidi; Miller, Karla L; Smith, Stephen M; Fischl, Bruce; Sotiropoulos, Stamatios N

    2017-02-23

    The study of neuroanatomy using imaging enables key insights into how our brains function, are shaped by genes and environment, and change with development, aging and disease. Developments in MRI acquisition, image processing and data modeling have been key to these advances. However, MRI provides an indirect measurement of the biological signals we aim to investigate. Thus, artifacts and key questions of correct interpretation can confound the readouts provided by anatomical MRI. In this review we provide an overview of the methods for measuring macro- and mesoscopic structure and for inferring microstructural properties; we also describe key artifacts and confounds that can lead to incorrect conclusions. Ultimately, we believe that, although methods need to improve and caution is required in interpretation, structural MRI continues to have great promise in furthering our understanding of how the brain works.

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... any recent surgeries. Some conditions, such as severe kidney disease, may prevent you from being given gadolinium ... an MRI. If you have a history of kidney disease or liver transplant, it will be necessary ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... your regular medications as usual. Leave jewelry at home and wear loose, comfortable clothing. You may be ... Jewelry and other accessories should be left at home, if possible, or removed prior to the MRI ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want to ask your ... there is any question of their presence, an x-ray may be taken to detect and identify ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  8. Towards MRI microarrays.

    Science.gov (United States)

    Hall, Andrew; Mundell, Victoria J; Blanco-Andujar, Cristina; Bencsik, Martin; McHale, Glen; Newton, Michael I; Cave, Gareth W V

    2010-04-14

    Superparamagnetic iron oxide nanometre scale particles have been utilised as contrast agents to image staked target binding oligonucleotide arrays using MRI to correlate the signal intensity and T(2)* relaxation times in different NMR fluids.

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... Thus, the child remains motionless allowing for good quality images. Jewelry and other accessories should be left ... claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older open ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with ... exam and bring it to your exam in case the radiologist or technologist has any questions. Some ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... data suggest that it is safe to continue breastfeeding after receiving intravenous contrast. For further information please ...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... used in tattoos may contain iron and could heat up during an MRI scan, but this is ... from the contrast material, including nausea, headache and pain at the site of injection. Similarly, patients are ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... contrast material in patients with very poor kidney function. Careful assessment of kidney function before considering a ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... used in tattoos may contain iron and could heat up during an MRI scan, but this is ... preferred imaging test. MR imaging can assess blood flow without risking the side effects of conventional (catheter) ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... as severe kidney disease, may prevent you from being given gadolinium contrast for an MRI. If you ... can watch a movie while the scan is being performed. Thus, the child remains motionless allowing for ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the scheduler before the exam and bring ... bore which can be more comfortable for larger size patients or patients with claustrophobia. Other MRI machines ...

  17. Imaging children suffering from lymphoma: an evaluation of different 18F-FDG PET/MRI protocols compared to whole-body DW-MRI.

    Science.gov (United States)

    Kirchner, Julian; Deuschl, Cornelius; Schweiger, Bernd; Herrmann, Ken; Forsting, Michael; Buchbender, Christian; Antoch, Gerald; Umutlu, Lale

    2017-09-01

    The objectives of this study were to evaluate and compare the diagnostic potential of different PET/MRI reading protocols, entailing non-enhanced / contrast-enhanced and diffusion-weighted 18 F-FDG PET/MR imaging and whole-body diffusion-weighted MRI for lesion detection and determination of the tumor stage in pediatric lymphoma patients. A total of 28 18 F-FDG PET/MRI datasets were included for analysis of four different reading protocols: (1) PET/MRI utilizing sole unenhanced T2w and T1w imaging, (2) PET/MRI utilizing additional contrast enhanced sequences, (3) PET/MR imaging utilizing unenhanced, contrast enhanced and DW imaging or (4) WB-DW-MRI. Statistical analyses were performed on a per-patient and a per-lesion basis. Follow-up and prior examinations as well as histopathology served as reference standards. PET/MRI correctly identified all 17 examinations with active lymphoma disease, while WB-DW-MRI correctly identified 15/17 examinations. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy were 96%, 96.5%, 97%, 95%, and 96% for PET/MRI 1 ; 97%, 96.5%, 97%, 96.5%, and 97% for PET/MRI 2 ; 97%, 96.5%, 97%, 96.5%, and 97% for PET/MRI 3 and 77%, 96%, 96%, 78.5% and 86% for MRI-DWI. 18 F-FDG PET/MRI is superior to WB-DW-MRI in staging pediatric lymphoma patients. Neither application of contrast media nor DWI leads to a noticeable improvement of the diagnostic accuracy of PET/MRI. Thus, unenhanced PET/MRI may play a crucial role for the diagnostic work-up of pediatric lymphoma patients in the future.

  18. Imaging children suffering from lymphoma: an evaluation of different {sup 18}F-FDG PET/MRI protocols compared to whole-body DW-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kirchner, Julian; Buchbender, Christian; Antoch, Gerald [University Dusseldorf, Department of Diagnostic and Interventional Radiology, Medical Faculty, Dusseldorf (Germany); Deuschl, Cornelius; Schweiger, Bernd; Forsting, Michael; Umutlu, Lale [University Hospital Essen, University of Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Herrmann, Ken [University Hospital Essen, University of Duisburg-Essen, Department of Nuclear Medicine, Essen (Germany)

    2017-09-15

    The objectives of this study were to evaluate and compare the diagnostic potential of different PET/MRI reading protocols, entailing non-enhanced / contrast-enhanced and diffusion-weighted {sup 18}F-FDG PET/MR imaging and whole-body diffusion-weighted MRI for lesion detection and determination of the tumor stage in pediatric lymphoma patients. A total of 28 {sup 18}F-FDG PET/MRI datasets were included for analysis of four different reading protocols: (1) PET/MRI utilizing sole unenhanced T2w and T1w imaging, (2) PET/MRI utilizing additional contrast enhanced sequences, (3) PET/MR imaging utilizing unenhanced, contrast enhanced and DW imaging or (4) WB-DW-MRI. Statistical analyses were performed on a per-patient and a per-lesion basis. Follow-up and prior examinations as well as histopathology served as reference standards. PET/MRI correctly identified all 17 examinations with active lymphoma disease, while WB-DW-MRI correctly identified 15/17 examinations. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy were 96%, 96.5%, 97%, 95%, and 96% for PET/MRI{sub 1}; 97%, 96.5%, 97%, 96.5%, and 97% for PET/MRI{sub 2}; 97%, 96.5%, 97%, 96.5%, and 97% for PET/MRI{sub 3} and 77%, 96%, 96%, 78.5% and 86% for MRI-DWI. {sup 18}F-FDG PET/MRI is superior to WB-DW-MRI in staging pediatric lymphoma patients. Neither application of contrast media nor DWI leads to a noticeable improvement of the diagnostic accuracy of PET/MRI. Thus, unenhanced PET/MRI may play a crucial role for the diagnostic work-up of pediatric lymphoma patients in the future. (orig.)

  19. MRI in osteochondrosis dissecans

    Energy Technology Data Exchange (ETDEWEB)

    Lehner, K.; Heuck, A.; Rodammer, G.; Raff, W.; Haller, W.

    1987-08-01

    The osseous manifestations of osteochondrosis dissecans are well demonstrated by conventional and computerised tomography. Beyond that, magnetic resonance imaging (MRI) is effective in evaluating the vitality and loosening of an osseous dissecate. Subchondral cavities and cartilaginous defects are detected with high acccuracy. Further, MRI seems to be a useful method in childhood to differentiate a variant irregularity of the osseous articular surface from definite osteochondrosis dissecans.

  20. MRI assessment program

    International Nuclear Information System (INIS)

    1987-09-01

    The MRI Assessment Program involves installation and operation of five MRI units in Australian public hospitals and the evaluation at each unit of the cost and efficacy of the technology over a period of two years. This first report in a series presents preliminary usage and cost data for the year to 30 June 1987 as well as describing the background and the data set. 6 figs., tabs

  1. High resolution anatomical and quantitative MRI of the entire human occipital lobe ex vivo at 9.4 T

    NARCIS (Netherlands)

    Sengupta, S.; Lagos Fritz, F.J.; Harms, R.L.; Hildebrand, S.; Tse, D.H.Y.; Poser, B.A.; Goebel, R.; Roebroeck, A.

    Several magnetic resonance imaging (MRI) contrasts are sensitive to myelin content in gray matter in vivo which has ignited ambitions of MRI-based in vivo cortical histology. Ultra-high field (UHF) MRI, at fields of 7 T and beyond, is crucial to provide the resolution and contrast needed to sample

  2. Functional MRI of the patellofemoral joint: comparison of ultrafast MRI, motion-triggered cine MRI and static MRI

    Energy Technology Data Exchange (ETDEWEB)

    Muhle, C. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Brossmann, J. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Melchert, U.H. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Schroeder, C. [Radiologische Abt., Universitaets-Kinderklinik, Christian-Albrechts-Universitaet, Kiel (Germany); Boer, R. de [Philips Medical Systems, Best (Netherlands); Spielmann, R.P. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Heller, M. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany)

    1995-12-31

    To evaluate the feasibility and usefulness of ultrafast MRI (u), patellar tracking from 30 of flexion to knee extension (0 ) was analysed and compared with motion-triggered cine MRI (m) and a static MRI technique (s). The different imaging methods were compared in respect of the patellofemoral relationship, the examination time and image quality. Eight healthy subjects and four patients (in total 18 joints) with patellar subluxation or luxation were examined. Significant differences between the static MRI series without quadriceps contraction and the functional MRI studies (motion-triggered cine MRI and ultrafast MRI) were found for the patellar tilt angle. In the dynamic joint studies there was no statistical difference of the regression coefficients between the motion-triggered cine MRI studies and the ultrafast MRI studies. The findings of the functional MRI studies compared with the static MRI images were significantly different for the lateralisation of the patella, expressed by the lateral patellar displacement and bisect offset. No significant differences in patellar lateralisation were found between motion-triggered cine MRI and ultrafast MRI. Ultrafast MRI was superior to motion-triggered cine MRI in terms of the reduction in imaging time and improvement of the image quality. (orig.)

  3. Functional MRI of the patellofemoral joint: comparison of ultrafast MRI, motion-triggered cine MRI and static MRI

    International Nuclear Information System (INIS)

    Muhle, C.; Brossmann, J.; Melchert, U.H.; Schroeder, C.; Boer, R. de; Spielmann, R.P.; Heller, M.

    1995-01-01

    To evaluate the feasibility and usefulness of ultrafast MRI (u), patellar tracking from 30 of flexion to knee extension (0 ) was analysed and compared with motion-triggered cine MRI (m) and a static MRI technique (s). The different imaging methods were compared in respect of the patellofemoral relationship, the examination time and image quality. Eight healthy subjects and four patients (in total 18 joints) with patellar subluxation or luxation were examined. Significant differences between the static MRI series without quadriceps contraction and the functional MRI studies (motion-triggered cine MRI and ultrafast MRI) were found for the patellar tilt angle. In the dynamic joint studies there was no statistical difference of the regression coefficients between the motion-triggered cine MRI studies and the ultrafast MRI studies. The findings of the functional MRI studies compared with the static MRI images were significantly different for the lateralisation of the patella, expressed by the lateral patellar displacement and bisect offset. No significant differences in patellar lateralisation were found between motion-triggered cine MRI and ultrafast MRI. Ultrafast MRI was superior to motion-triggered cine MRI in terms of the reduction in imaging time and improvement of the image quality. (orig.)

  4. MRI of head trauma. Serial changes and comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Osamu; Sato, Shuji; Suzuki, Takashi; Endo, Shunro; Takaku, Akira.

    1988-08-01

    Sequential changes in magnetic resonance imaging (MRI) were investigated in comparison with computed tomography (CT) in 31 cases of head trauma. Twenty-one of them were of acute head trauma; the first MRI study was performed within 48 hours after the accident. Forty-two intracranial lesions were observed in these cases on MRI. The other 10 cases were of chronic subdural hematoma, two cases of which had bilateral lesions. Fourteen lesions of acute head trauma and two lesions of chronic subdural hematoma were detected only by MRI. MRI was superior to CT for the detection of small contusions and thin extra-axial collections, especially those which were located near the bony structures. The abnormal lesions were visualized in MRI during a longer period than in CT. Because the signal intensity of a hematoma changed sequentially, the detection of brain edema was easier than that of a subarachnoid and parenchimal hemorrhage. Judging from this experience, it seems that careful attention should be taken in the diagnosis of hemorrhagic lesions. However, MRI was poor in tissue characterization because of the too-high tissue sensitivity. T/sub 2/-weight SE imaging was essentially sensitive and useful in the early stage.

  5. MRI evaluation of the posterior meniscus root tear

    International Nuclear Information System (INIS)

    Zhang Jianjun; Zheng Zhuozhao; Li Xuan

    2010-01-01

    Objective: To determine the value of MRI for diagnosing the posterior meniscus root tear. Methods: MR examinations of 30 patients with tear of the posterior meniscus root confirmed by knee arthroscopies were retrospectively reviewed. Of the 30 patients, 17 with posterior medial meniscus root tear (MMRT) and 13 with posterior lateral meniscus root tear (LMRT). The diagnostic sensitivity of' MRI for the posterior meniscus root tear was analyzed. Fisher's exact test was used to compare the detection rate of MRI for MMRT with that for LMRT. Results: All 17 cases with MMRT and 9 cases out of 13 with LMRT were correctly diagnosed by MRI and the diagnostic sensitivity of MRI for the posterior meniscus root tear was 86.7% (26/30). The main MR appearance of the posterior meniscus root tear was distortion of the meniscal root, with its low signal replaced by abnormal high signal. The detection rate of MRI for MMRT (17/17) was significantly greater than that for LMRT (9/13) (P=0.026). The prevalence of MMRT associated with meniscus extrusion (15/17) was significantly greater than that of LMRT (6/13) (P=0.020), but the prevalence of MMRT associated with anterior cruciate ligament (ACL) injury (5/17) was significantly lower than that of LMRT (11/13) (P=0.004). Conclusion: MRI is a relatively good method for detection of posterior meniscus root tears and associated injuries. (authors)

  6. Fusion of PET and MRI for Hybrid Imaging

    Science.gov (United States)

    Cho, Zang-Hee; Son, Young-Don; Kim, Young-Bo; Yoo, Seung-Schik

    Recently, the development of the fusion PET-MRI system has been actively studied to meet the increasing demand for integrated molecular and anatomical imaging. MRI can provide detailed anatomical information on the brain, such as the locations of gray and white matter, blood vessels, axonal tracts with high resolution, while PET can measure molecular and genetic information, such as glucose metabolism, neurotransmitter-neuroreceptor binding and affinity, protein-protein interactions, and gene trafficking among biological tissues. State-of-the-art MRI systems, such as the 7.0 T whole-body MRI, now can visualize super-fine structures including neuronal bundles in the pons, fine blood vessels (such as lenticulostriate arteries) without invasive contrast agents, in vivo hippocampal substructures, and substantia nigra with excellent image contrast. High-resolution PET, known as High-Resolution Research Tomograph (HRRT), is a brain-dedicated system capable of imaging minute changes of chemicals, such as neurotransmitters and -receptors, with high spatial resolution and sensitivity. The synergistic power of the two, i.e., ultra high-resolution anatomical information offered by a 7.0 T MRI system combined with the high-sensitivity molecular information offered by HRRT-PET, will significantly elevate the level of our current understanding of the human brain, one of the most delicate, complex, and mysterious biological organs. This chapter introduces MRI, PET, and PET-MRI fusion system, and its algorithms are discussed in detail.

  7. MRI of persistent cloaca: Can it substitute conventional imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Mohammad, Shaimaa Abdelsattar, E-mail: shaimaa96@hotmail.com [Department of Radiodiagnosis, Faculty of Medicine, Ain-Shams University (Egypt); AbouZeid, Amr Abdelhamid, E-mail: amrabdelhamid@hotmail.com [Department of Pediatric Surgery, Faculty of Medicine, Ain-Shams University (Egypt)

    2013-02-15

    Purpose: To define the role of MRI in the preoperative assessment of patients with persistent cloaca and whether it can substitute other imaging modalities. Methods: We prospectively examined eleven patients with persistent cloaca between July 2007 and March 2012. Non contrast MRI examinations were performed on 1.5 T magnet using head coil. Multiple pulse sequences (T1WI, T2WI, fat suppression) were obtained in axial, sagittal and coronal planes of the pelvis, abdomen, and spine. The scans were reviewed for the following: the level and type of rectal termination, the developmental state of striated muscle complex (SMC), associated genitourinary and spinal anomalies. MRI findings were compared to conventional fluoroscopic imaging, operative and endoscopic findings. We applied novel MRI parameters (urethral length, relative hiatal distance and vaginal volume). The relation between different parameters was tested statistically using Pearson correlation test. Results: MRI could accurately demonstrate the level of bowel termination in patients with persistent cloaca, in addition to its high sensitivity for detection of mullerian anomalies which were present in 73% of patients. Furthermore, MRI could disclose associating renal and spinal anomalies, and assess the developmental state of SMC. The shorter the urethra (higher urogenital confluence), the narrower the pelvic hiatus, and the more was the obstruction (vaginal distension). Conclusion: MRI is a valuable tool in exploring the different internal anatomical features of the cloacal anomaly; and when combined with endoscopy, MRI can make other preoperative conventional imaging unnecessary.

  8. Breast MRI: EUSOBI recommendations for women's information

    International Nuclear Information System (INIS)

    Mann, Ritse M.; Balleyguier, Corinne; Baltzer, Pascal A.; Helbich, Thomas H.; Pinker-Domenig, Katja; Bick, Ulrich; Fallenberg, Eva; Colin, Catherine; Cornford, Eleanor; Evans, Andrew; Forrai, Gabor; Fuchsjaeger, Michael H.; Gilbert, Fiona J.; Heywang-Koebrunner, Sylvia H.; Camps-Herrero, Julia; Kuhl, Christiane K.; Martincich, Laura; Pediconi, Federica; Panizza, Pietro; Pina, Luis J.; Pijnappel, Ruud M.; Skaane, Per; Sardanelli, Francesco

    2015-01-01

    This paper summarizes information about breast MRI to be provided to women and referring physicians. After listing contraindications, procedure details are described, stressing the need for correct scheduling and not moving during the examination. The structured report including BI-RADS registered categories and further actions after a breast MRI examination are discussed. Breast MRI is a very sensitive modality, significantly improving screening in high-risk women. It also has a role in clinical diagnosis, problem solving, and staging, impacting on patient management. However, it is not a perfect test, and occasionally breast cancers can be missed. Therefore, clinical and other imaging findings (from mammography/ultrasound) should also be considered. Conversely, MRI may detect lesions not visible on other imaging modalities turning out to be benign (false positives). These risks should be discussed with women before a breast MRI is requested/performed. Because breast MRI drawbacks depend upon the indication for the examination, basic information for the most important breast MRI indications is presented. Seventeen notes and five frequently asked questions formulated for use as direct communication to women are provided. The text was reviewed by Europa Donna-The European Breast Cancer Coalition to ensure that it can be easily understood by women undergoing MRI. (orig.)

  9. MRI findings of fetal cleft lip and palate

    International Nuclear Information System (INIS)

    Wang Guangbin; Chen Liguang; Zhu Xiangyu; Wang Cuiyan; Zhang Yinghua; Wang Liajuan; Li Huihua; Qiu Xiuling; Qu Lei; Wei Yulong; Ding Rui; Sun Xueqin

    2010-01-01

    Objective: To investigate the MR findings of fetal cleft lip (CL) and evaluate the advantages and limitations of MRI in the diagnosis. Methods: Twelve pregnant women suspicious of fetal CL/cleft palate (CP) on ultrasonography were enrolled in the study. The findings of ultrasonography, MRI and following-up were compared. Results: MRI and ultrasonography detected 12 fetuses with CL/CP. The following-up results showed 1 case with incomplete cleft lip and the other 11 cases with complete cleft lips and cleft palates. MRI and unltrasonography were consistent with the follow-up in CL detection, showing completed or uncompleted soft tissue interruption of the fetal lips with amniotic fluid filling which is high signal on T 2 WI. On MRI, CP showed discontinuous of the soft tissue which were interrupted by long T 2 signal and communicating with oral cavity ad nasal cavity. MRI missed 1 case and excluded 1 case of CP. Ultrasonography predicted 5 case of CL, excluded 1 CP but missed 6 cases. The accuracy, sensitivity and specificity in detection CL/CP was 91.7% (11/12), 90.9% (10/11), 100% (1/1) for MRI and 50.0% (6/12), 45.5% (5/11), 100% (1/1) for ultrasonography, respectively. Conclusion: MR imaging had advantage over ultrasonography in detecting CP, MRI is an essential when CP is suspicious on ultrasonography. (authors)

  10. Breast MRI: EUSOBI recommendations for women's information

    Energy Technology Data Exchange (ETDEWEB)

    Mann, Ritse M. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); Balleyguier, Corinne [Gustave-Roussy Institute, Department of Radiology, Villejuif (France); Baltzer, Pascal A.; Helbich, Thomas H.; Pinker-Domenig, Katja [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Vienna (Austria); Bick, Ulrich; Fallenberg, Eva [Universitaetsmedizin Berlin, Clinic of Radiology, Charite, Berlin (Germany); Colin, Catherine [Centre Hospitalo-Universitaire Lyon Sud, Radiology Unit, Hospices Civils de Lyon, Pierre Benite Cedex (France); Cornford, Eleanor [Nottingham University Hospitals, Nottingham Breast Institute, Nottingham (United Kingdom); Evans, Andrew [Ninewells Hospital and Medical School, Dundee Cancer Centre, Clinical Research Centre, Dundee (United Kingdom); Forrai, Gabor [MHEK Teaching Hospital University Semmelweis, Budapest (Hungary); Fuchsjaeger, Michael H. [Medical University of Graz, Department of Radiology, Graz (Austria); Gilbert, Fiona J. [University of Cambridge, School of Clinical Medicine, Department of Radiology, Cambridge (United Kingdom); Heywang-Koebrunner, Sylvia H. [National Reference Centre Mammography, Munich, Munich (Germany); Camps-Herrero, Julia [Hospital de la Ribera, Department of Radiology, Alzira, Valencia (Spain); Kuhl, Christiane K. [University Hospital of Aachen, Rheinisch-Westfaelische Technische Hochschule, Aachen (Germany); Martincich, Laura [IRCCS-FPO, Radiology Unit, Candiolo, Turin (Italy); Pediconi, Federica [Sapienza University, Department of Radiological, Oncological and Pathological Sciences, Rome (Italy); Panizza, Pietro [Fondazione IRCCS Istituto Nazionale dei Tumori, Department of Radiology 1, Milan (Italy); Pina, Luis J. [Clinica Universidad de Navarra, Department of Radiology, Pamplona, Navarra (Spain); Pijnappel, Ruud M. [University Medical Centre Utrecht, Department of Imaging, Utrecht (Netherlands); Skaane, Per [Oslo University Hospital Ullevaal, University of Oslo, Department of Radiology, Oslo (Norway); Sardanelli, Francesco [Universita degli Studi di Milano, Radiology Unit, IRCCS Policlinico San Donato, Department of Biomedical Sciences for Health, San Donato Milanese, Milan (Italy); Collaboration: for the European Society of Breast Imaging (EUSOBI), with language review by Europa Donna-The European Breast Cancer Coalition

    2015-12-15

    This paper summarizes information about breast MRI to be provided to women and referring physicians. After listing contraindications, procedure details are described, stressing the need for correct scheduling and not moving during the examination. The structured report including BI-RADS registered categories and further actions after a breast MRI examination are discussed. Breast MRI is a very sensitive modality, significantly improving screening in high-risk women. It also has a role in clinical diagnosis, problem solving, and staging, impacting on patient management. However, it is not a perfect test, and occasionally breast cancers can be missed. Therefore, clinical and other imaging findings (from mammography/ultrasound) should also be considered. Conversely, MRI may detect lesions not visible on other imaging modalities turning out to be benign (false positives). These risks should be discussed with women before a breast MRI is requested/performed. Because breast MRI drawbacks depend upon the indication for the examination, basic information for the most important breast MRI indications is presented. Seventeen notes and five frequently asked questions formulated for use as direct communication to women are provided. The text was reviewed by Europa Donna-The European Breast Cancer Coalition to ensure that it can be easily understood by women undergoing MRI. (orig.)

  11. Cine MRI: a new approach to the diagnosis of scapholunate dissociation.

    Science.gov (United States)

    Langner, I; Fischer, S; Eisenschenk, A; Langner, S

    2015-08-01

    To evaluate the feasibility of cine MRI for the detection of scapholunate dissociation (SLD) and to compare the sensitivity and specificity of cine MRI with those of cineradiography and arthroscopy. To evaluate feasibility, healthy subjects underwent cine MRI of the wrist. To evaluate sensitivity and specificity, patients with clinically suspected scapholunate ligament (SLL) injury after trauma to the wrist were prospectively included and underwent radiographic examination, cineradiography, and cine MRI. In 25 out of 38 patients, subsequent arthroscopy was performed. Results of cineradiography and cine MRI correlated with those of arthroscopy. Cine MRI was of diagnostic quality in all healthy subjects and patients with good interrater agreement. There was excellent correlation between cineradiography and cine MRI. Scapholunate distance differed significantly between healthy subjects and patients with scapholunate dissociation (p Cine MRI had 85% sensitivity and 90% specificity for the detection of SLD. Cine MRI of the wrist is a fast and reliable technique for the detection of SLD with diagnostic accuracy comparable to cineradiography. It can be easily implemented as a routine clinical MRI examination, facilitating diagnostic workup of patients with suspected SLD while avoiding radiation exposure.

  12. Comparative diagnostic performance of multidetector computed tomography and MRI for characterization of pancreatic cystic lesions

    International Nuclear Information System (INIS)

    Moon, Sung Min; Shin, Sang Soo; Park, Jin Gyoon; Jeong, Yong Yeon

    2015-01-01

    To compare the diagnostic performance of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in characterization of pancreatic cystic lesions. We conducted a retrospective study on 34 patients with histopathologically proven cystic pancreatic lesions who underwent both preoperative MDCT and MRI. CT and MRI were independently evaluated for differentiating mucinous vs. non-mucinous lesions, differentiating aggressive vs. non-aggressive lesion, analyzing morphological features, and evaluating specific leading diagnoses. Sensitivity, specificity, and accuracy were determined. Competency assessment of lesional morphology analysis was performed using the kappa values of the 2 tests. The sensitivity, specificity, and accuracy of MRI for differentiating mucinous vs. non-mucinous lesions were higher than CT (p = 0.03). For differentiating aggressiveness, the sensitivity of MRI was better than CT, but the specificity of CT was better than MRI. In evaluation of morphologic features, MRI showed better performance in characterization of septa and wall. Otherwise, the 2 modalities showed similarly good performance. MRI was better than CT in determining a specific diagnosis (58.8% vs. 47.2%, respectively). CT and MRI are reasonable diagnostic methods for characterization of pancreatic cystic lesions. However, MRI enables more confident assessment than CT in differentiating mucinous vs. non-mucinous lesions and characterization of the septa and wall

  13. Cine MRI: a new approach to the diagnosis of scapholunate dissociation

    Energy Technology Data Exchange (ETDEWEB)

    Langner, I.; Eisenschenk, A. [University Medicine Greifswald, Division of Hand Surgery and Functional Microsurgery, Department of Trauma and Reconstructive Surgery, Greifswald (Germany); Fischer, S.; Langner, S. [University Medicine Greifswald, Institute for Diagnostic Radiology and Neuroradiology, Greifswald (Germany)

    2015-08-15

    To evaluate the feasibility of cine MRI for the detection of scapholunate dissociation (SLD) and to compare the sensitivity and specificity of cine MRI with those of cineradiography and arthroscopy. To evaluate feasibility, healthy subjects underwent cine MRI of the wrist. To evaluate sensitivity and specificity, patients with clinically suspected scapholunate ligament (SLL) injury after trauma to the wrist were prospectively included and underwent radiographic examination, cineradiography, and cine MRI. In 25 out of 38 patients, subsequent arthroscopy was performed. Results of cineradiography and cine MRI correlated with those of arthroscopy. Cine MRI was of diagnostic quality in all healthy subjects and patients with good interrater agreement. There was excellent correlation between cineradiography and cine MRI. Scapholunate distance differed significantly between healthy subjects and patients with scapholunate dissociation (p < 0.001), but not between imaging modalities in the patient group. Cine MRI had 85 % sensitivity and 90 % specificity for the detection of SLD. Cine MRI of the wrist is a fast and reliable technique for the detection of SLD with diagnostic accuracy comparable to cineradiography. It can be easily implemented as a routine clinical MRI examination, facilitating diagnostic workup of patients with suspected SLD while avoiding radiation exposure. (orig.)

  14. Assessment of CF lung disease using motion corrected PROPELLER MRI: a comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Ciet, Pierluigi [General Hospital Ca' Foncello, Radiology Department, Treviso (Italy); Sophia Children' s Hospital, Pediatric Pulmonology Erasmus MC, Rotterdam (Netherlands); Erasmus MC, Radiology, Rotterdam (Netherlands); Serra, Goffredo; Catalano, Carlo [University of Rome ' ' Sapienza' ' , Radiology, Rome (Italy); Bertolo, Silvia; Morana, Giovanni [General Hospital Ca' Foncello, Radiology Department, Treviso (Italy); Spronk, Sandra [Erasmus MC, Radiology, Rotterdam (Netherlands); Erasmus MC, Epidemiology, Rotterdam (Netherlands); Ros, Mirco [Ca' Foncello Hospital, Pediatrics, Treviso (Italy); Fraioli, Francesco [University College London (UCL), Institute of Nuclear Medicine, London (United Kingdom); Quattrucci, Serena [University of Rome Sapienza, Pediatrics, Rome (Italy); Assael, M.B. [Azienda Ospedaliera di Verona, Verona CF Center, Verona (Italy); Pomerri, Fabio [University of Padova, Department of Medicine-DIMED, Padova (Italy); Tiddens, Harm A.W.M. [Sophia Children' s Hospital, Pediatric Pulmonology Erasmus MC, Rotterdam (Netherlands); Erasmus MC, Radiology, Rotterdam (Netherlands)

    2016-03-15

    To date, PROPELLER MRI, a breathing-motion-insensitive technique, has not been assessed for cystic fibrosis (CF) lung disease. We compared this technique to CT for assessing CF lung disease in children and adults. Thirty-eight stable CF patients (median 21 years, range 6-51 years, 22 female) underwent MRI and CT on the same day. Study protocol included respiratory-triggered PROPELLER MRI and volumetric CT end-inspiratory and -expiratory acquisitions. Two observers scored the images using the CF-MRI and CF-CT systems. Scores were compared with intra-class correlation coefficient (ICC) and Bland-Altman plots. The sensitivity and specificity of MRI versus CT were calculated. MRI sensitivity for detecting severe CF bronchiectasis was 0.33 (CI 0.09-0.57), while specificity was 100 % (CI 0.88-1). ICCs for bronchiectasis and trapped air were as follows: MRI-bronchiectasis (0.79); CT-bronchiectasis (0.85); MRI-trapped air (0.51); CT-trapped air (0.87). Bland-Altman plots showed an MRI tendency to overestimate the severity of bronchiectasis in mild CF disease and underestimate bronchiectasis in severe disease. Motion correction in PROPELLER MRI does not improve assessment of CF lung disease compared to CT. However, the good inter- and intra-observer agreement and the high specificity suggest that MRI might play a role in the short-term follow-up of CF lung disease (i.e. pulmonary exacerbations). (orig.)

  15. Assessment of CF lung disease using motion corrected PROPELLER MRI: a comparison with CT

    International Nuclear Information System (INIS)

    Ciet, Pierluigi; Serra, Goffredo; Catalano, Carlo; Bertolo, Silvia; Morana, Giovanni; Spronk, Sandra; Ros, Mirco; Fraioli, Francesco; Quattrucci, Serena; Assael, M.B.; Pomerri, Fabio; Tiddens, Harm A.W.M.

    2016-01-01

    To date, PROPELLER MRI, a breathing-motion-insensitive technique, has not been assessed for cystic fibrosis (CF) lung disease. We compared this technique to CT for assessing CF lung disease in children and adults. Thirty-eight stable CF patients (median 21 years, range 6-51 years, 22 female) underwent MRI and CT on the same day. Study protocol included respiratory-triggered PROPELLER MRI and volumetric CT end-inspiratory and -expiratory acquisitions. Two observers scored the images using the CF-MRI and CF-CT systems. Scores were compared with intra-class correlation coefficient (ICC) and Bland-Altman plots. The sensitivity and specificity of MRI versus CT were calculated. MRI sensitivity for detecting severe CF bronchiectasis was 0.33 (CI 0.09-0.57), while specificity was 100 % (CI 0.88-1). ICCs for bronchiectasis and trapped air were as follows: MRI-bronchiectasis (0.79); CT-bronchiectasis (0.85); MRI-trapped air (0.51); CT-trapped air (0.87). Bland-Altman plots showed an MRI tendency to overestimate the severity of bronchiectasis in mild CF disease and underestimate bronchiectasis in severe disease. Motion correction in PROPELLER MRI does not improve assessment of CF lung disease compared to CT. However, the good inter- and intra-observer agreement and the high specificity suggest that MRI might play a role in the short-term follow-up of CF lung disease (i.e. pulmonary exacerbations). (orig.)

  16. Cine MRI of dissecting aneurysm

    International Nuclear Information System (INIS)

    Takaki, Hajime

    1991-01-01

    Cine MRI was performed in 25 cases of aortic dissection and comparative study among cine MRI, spin-echo static MRI, contrast-enhanced CT and intravenous digital subtraction angiography (IVDSA) was made. Cine MRI accurately detected aortic dissection. It was most accurate among various diagnostic methods in demonstration of entry site of dissection. Take-off of renal artery and its relation to true and false channels was also accurately demonstrated by cine MRI. The above results suggest that cine MRI can be an important diagnostic modality with almost equal diagnostic quality to those of conventional angiography. However, further technical improvement to shorten the imaging time seems necessary to replace angiography. (author)

  17. Combined PET/MRI

    DEFF Research Database (Denmark)

    Bailey, D L; Pichler, B J; Gückel, B

    2018-01-01

    The 6th annual meeting to address key issues in positron emission tomography (PET)/magnetic resonance imaging (MRI) was held again in Tübingen, Germany, from March 27 to 29, 2017. Over three days of invited plenary lectures, round table discussions and dialogue board deliberations, participants c...... of response to pharmacological interventions and therapies. As such, PET/MRI is a key to advancing medicine and patient care.......The 6th annual meeting to address key issues in positron emission tomography (PET)/magnetic resonance imaging (MRI) was held again in Tübingen, Germany, from March 27 to 29, 2017. Over three days of invited plenary lectures, round table discussions and dialogue board deliberations, participants...... critically assessed the current state of PET/MRI, both clinically and as a research tool, and attempted to chart future directions. The meeting addressed the use of PET/MRI and workflows in oncology, neurosciences, infection, inflammation and chronic pain syndromes, as well as deeper discussions about how...

  18. MRI of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Kauczor, Hans-Ulrich (ed.) [University Clinic Heidelberg (Germany). Diagnostic and Interventional Radiology

    2009-07-01

    For a long time, only chest X-ray and CT were used to image lung structure, while nuclear medicine was employed to assess lung function. During the past decade significant developments have been achieved in the field of magnetic resonance imaging (MRI), enabling MRI to enter the clinical arena of chest imaging. Standard protocols can now be implemented on up-to-date scanners, allowing MRI to be used as a first-line imaging modality for various lung diseases, including cystic fibrosis, pulmonary hypertension and even lung cancer. The diagnostic benefits stem from the ability of MRI to visualize changes in lung structure while simultaneously imaging different aspects of lung function, such as perfusion, respiratory motion, ventilation and gas exchange. On this basis, novel quantitative surrogates for lung function can be obtained. This book provides a comprehensive overview of how to use MRI for imaging of lung disease. Special emphasis is placed on benign diseases requiring regular monitoring, given that it is patients with these diseases who derive the greatest benefit from the avoidance of ionizing radiation. (orig.)

  19. Elemental imaging of MRI contrast agents: benchmarking of LA-ICP-MS to MRI

    Energy Technology Data Exchange (ETDEWEB)

    Pugh, J.A.T. [University of Sheffield, Centre for Analytical Sciences, Sheffield (United Kingdom); University of Sheffield, Department of Chemical and Biological Engineering, Sheffield (United Kingdom); Cox, A.G.; McLeod, C.W. [University of Sheffield, Centre for Analytical Sciences, Sheffield (United Kingdom); Bunch, J. [University of Birmingham, School of Chemistry, Birmingham (United Kingdom); Writer, M.J.; Hart, S.L. [UCL Institute of Child Health, Wolfson Centre for Gene Therapy of Childhood Disease, London (United Kingdom); Bienemann, A.; White, E. [University of Bristol, School of Clinical Sciences, Southmead Hospital, Bristol (United Kingdom); Bell, J. [Hammersmith Hospital, Metabolic and Molecular Imaging Group, MRC Clinical Sciences Centre, Imperial College London, London (United Kingdom)

    2012-06-15

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been used to map the spatial distribution of magnetic resonance imaging (MRI) contrast agents (Gd-based) in histological sections in order to explore synergies with in vivo MRI. Images from respective techniques are presented for two separate studies namely (1) convection enhanced delivery of a Gd nanocomplex (developmental therapeutic) into rat brain and (2) convection enhanced delivery, with co-infusion of Magnevist (commercial Gd contrast agent) and Carboplatin (chemotherapy drug), into pig brain. The LA technique was shown to be a powerful compliment to MRI not only in offering improved sensitivity, spatial resolution and signal quantitation but also in giving added value regarding the fate of administered agents (Gd and Pt agents). Furthermore simultaneous measurement of Fe enabled assignment of an anomalous contrast enhancement region in rat brain to haemorrhage at the infusion site. (orig.)

  20. Comparison of a fast 5-min knee MRI protocol with a standard knee MRI protocol. A multi-institutional multi-reader study

    Energy Technology Data Exchange (ETDEWEB)

    FitzGerald Alaia, Erin; Beltran, Luis S.; Garwood, Elisabeth; Burke, Christopher J.; Gyftopoulos, Soterios [NYU Langone Medical Center, Department of Radiology, Musculoskeletal Division, New York, NY (United States); Benedick, Alex [Case Western Reserve University, School of Medicine, Cleveland, OH (United States); Obuchowski, Nancy A. [Cleveland Clinic, Department of Quantitative Health Sciences, Cleveland, OH (United States); Polster, Joshua M.; Schils, Jean; Subhas, Naveen [Cleveland Clinic, Department of Radiology, Musculoskeletal Division, Cleveland, OH (United States); Chang, I. Yuan Joseph [Texas Scottish Rite Hospital for Children, Dallas, TX (United States)

    2018-01-15

    To compare diagnostic performance of a 5-min knee MRI protocol to that of a standard knee MRI. One hundred 3 T (100 patients, mean 38.8 years) and 50 1.5 T (46 patients, mean 46.4 years) MRIs, consisting of 5 fast, 2D multi-planar fast-spin-echo (FSE) sequences and five standard multiplanar FSE sequences, from two academic centers (1/2015-1/2016), were retrospectively reviewed by four musculoskeletal radiologists. Agreement between fast and standard (interprotocol agreement) and between standard (intraprotocol agreement) readings for meniscal, ligamentous, chondral, and bone pathology was compared for interchangeability. Frequency of major findings, sensitivity, and specificity was also tested for each protocol. Interprotocol agreement using fast MRI was similar to intraprotocol agreement with standard MRI (83.0-99.5%), with no excess disagreement (≤ 1.2; 95% CI, -4.2 to 3.8%), across all structures. Frequency of major findings (1.1-22.4% across structures) on fast and standard MRI was not significantly different (p ≥ 0.215), except more ACL tears on fast MRI (p = 0.021) and more cartilage defects on standard MRI (p < 0.001). Sensitivities (59-100%) and specificities (73-99%) of fast and standard MRI were not significantly different for meniscal and ligament tears (95% CI for difference, -0.08-0.08). For cartilage defects, fast MRI was slightly less sensitive (95% CI for difference, -0.125 to -0.01) but slightly more specific (95% CI for difference, 0.01-0.5) than standard MRI. A fast 5-min MRI protocol is interchangeable with and has similar accuracy to a standard knee MRI for evaluating internal derangement of the knee. (orig.)

  1. Comparison of a fast 5-min knee MRI protocol with a standard knee MRI protocol. A multi-institutional multi-reader study

    International Nuclear Information System (INIS)

    FitzGerald Alaia, Erin; Beltran, Luis S.; Garwood, Elisabeth; Burke, Christopher J.; Gyftopoulos, Soterios; Benedick, Alex; Obuchowski, Nancy A.; Polster, Joshua M.; Schils, Jean; Subhas, Naveen; Chang, I. Yuan Joseph

    2018-01-01

    To compare diagnostic performance of a 5-min knee MRI protocol to that of a standard knee MRI. One hundred 3 T (100 patients, mean 38.8 years) and 50 1.5 T (46 patients, mean 46.4 years) MRIs, consisting of 5 fast, 2D multi-planar fast-spin-echo (FSE) sequences and five standard multiplanar FSE sequences, from two academic centers (1/2015-1/2016), were retrospectively reviewed by four musculoskeletal radiologists. Agreement between fast and standard (interprotocol agreement) and between standard (intraprotocol agreement) readings for meniscal, ligamentous, chondral, and bone pathology was compared for interchangeability. Frequency of major findings, sensitivity, and specificity was also tested for each protocol. Interprotocol agreement using fast MRI was similar to intraprotocol agreement with standard MRI (83.0-99.5%), with no excess disagreement (≤ 1.2; 95% CI, -4.2 to 3.8%), across all structures. Frequency of major findings (1.1-22.4% across structures) on fast and standard MRI was not significantly different (p ≥ 0.215), except more ACL tears on fast MRI (p = 0.021) and more cartilage defects on standard MRI (p < 0.001). Sensitivities (59-100%) and specificities (73-99%) of fast and standard MRI were not significantly different for meniscal and ligament tears (95% CI for difference, -0.08-0.08). For cartilage defects, fast MRI was slightly less sensitive (95% CI for difference, -0.125 to -0.01) but slightly more specific (95% CI for difference, 0.01-0.5) than standard MRI. A fast 5-min MRI protocol is interchangeable with and has similar accuracy to a standard knee MRI for evaluating internal derangement of the knee. (orig.)

  2. Controlled Hyperthermia with MRI-guided Focused Ultrasound

    DEFF Research Database (Denmark)

    Hokland, Steffen; Salomir, Rares; Pedersen, Michael

    Introduction: Hyperthermia is an appealing oncological treatment since the significant regions of hypoxia contained in most solid tumours are known to be sensitive to the cytotoxic effect of heat. However, due to the seemingly insurmountable technical difficulties associated with delivering thermal......-sensitive promoters and localized drug delivery using thermo-sensitive micro-carriers. Subjects Here we will present some of the recent advances in MRI-FUS, and their technical background. This will include: 1) Real-time MRI-thermometry. 2) FUS-technology. 3) Temporal and Spatial temperature control using MRI...... and penetration depth are governed by the wavelength. Hence for US it is possible to body non-invasively position sub-millimeter focal points in deep seated regions of the. Temperature Control: Most solid tumours cover volumes larger than that of the focal region. This problem may be reduced somewhat...

  3. MRI in gout

    International Nuclear Information System (INIS)

    Seidl, G.; Ullrich, R.; Trattnig, S.; Dominkus, M.; Morscher, M.; Aringer, M.; Imhof, H.

    1996-01-01

    The appearance of gouty tophus in magnetic resonance imaging (MRI) is characteristic. On T1- and T2-weighted SE images, the signal intensity of tophaceous lesions is similar to that of muscles. According to the histology, T2-weighted SE images demonstrate extremely hyperintense signals, which reflect the high protein content in the amorpheous center of the tophus. The microscopic urate crystals deposited there have no MRI signal and are of no further diagnostic impact. Vascularized granulation tissue surrounding the tophus center enhance after intervenous application of contrast agents (Gadolinium). The inflammed tophus is associated with local edema, causing high signal intensity. MRI is superior to plain radiography for early detection of intraosseous tophi. Involvement of anatomical structures such as ligaments and tendons can be evaluated sufficiently. For peripheral joints, axial slice orientation is most helpful. (orig.) [de

  4. MRI of oriental cholangiohepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Wani, N.A., E-mail: ahmad77chinar@gmail.co [Department of Radiodiagnosis and Imaging, Sher-I-Kashmir Institute of Medical Sciences (SKIMS), Srinagar (India); Robbani, I.; Kosar, T. [Department of Radiodiagnosis and Imaging, Sher-I-Kashmir Institute of Medical Sciences (SKIMS), Srinagar (India)

    2011-02-15

    Oriental cholangiohepatitis (OCH) also called recurrent pyogenic cholangitis is characterized by intrahepatic duct calculi, strictures, and recurrent infections. In turn cholangitis can result in multiple hepatic abscesses, further biliary strictures, and in severe cases, progressive hepatic parenchymal destruction, cirrhosis, and portal hypertension. Magnetic resonance cholangiopancreatography (MRCP) and conventional T1-weighted (T1 W) and T2-weighted (T2 W) magnetic resonance imaging (MRI) findings have been described in patients with OCH. MRCP findings include duct dilation, strictures, and calculi. MRCP can help to localize the diseased ducts and determine the severity of involvement. T1 and T2 W sequences reveal the parenchymal changes of atrophy, abscess formation, and portal hypertension in addition to calculi. Post-treatment changes are also well depicted using MRI. Comprehensive, non-invasive assessment is achieved by using conventional MRI and MRCP in OCH providing a roadmap for endoscopic or surgical management.

  5. Role of FDG-PET/MRI, FDG-PET/CT, and Dynamic Susceptibility Contrast Perfusion MRI in Differentiating Radiation Necrosis from Tumor Recurrence in Glioblastomas.

    Science.gov (United States)

    Hojjati, Mojgan; Badve, Chaitra; Garg, Vasant; Tatsuoka, Curtis; Rogers, Lisa; Sloan, Andrew; Faulhaber, Peter; Ros, Pablo R; Wolansky, Leo J

    2018-01-01

    To compare the utility of quantitative PET/MRI, dynamic susceptibility contrast (DSC) perfusion MRI (pMRI), and PET/CT in differentiating radiation necrosis (RN) from tumor recurrence (TR) in patients with treated glioblastoma multiforme (GBM). The study included 24 patients with GBM treated with surgery, radiotherapy, and temozolomide who presented with progression on imaging follow-up. All patients underwent PET/MRI and pMRI during a single examination. Additionally, 19 of 24 patients underwent PET/CT on the same day. Diagnosis was established by pathology in 17 of 24 and by clinical/radiologic consensus in 7 of 24. For the quantitative PET/MRI and PET/CT analysis, a region of interest (ROI) was drawn around each lesion and within the contralateral white matter. Lesion to contralateral white matter ratios for relative maximum, mean, and median were calculated. For pMRI, lesion ROI was drawn on the cerebral blood volume (CBV) maps and histogram metrics were calculated. Diagnostic performance for each metric was assessed using receiver operating characteristic curve analysis and area under curve (AUC) was calculated. In 24 patients, 28 lesions were identified. For PET/MRI, relative mean ≥ 1.31 resulted in AUC of .94 with both sensitivity and negative predictive values (NPVs) of 100%. For pMRI, CBV max ≥3.32 yielded an AUC of .94 with both sensitivity and NPV measuring 100%. The joint model utilizing r-mean (PET/MRI) and CBV mode (pMRI) resulted in AUC of 1.0. Our study demonstrates that quantitative PET/MRI parameters in combination with DSC pMRI provide the best diagnostic utility in distinguishing RN from TR in treated GBMs. © 2017 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  6. Breast MRI of ductal carcinoma in situ. Is there MRI role?

    International Nuclear Information System (INIS)

    Francescutti, G.E.; Londero, V.; Berra, I.; Del Frate, C.; Zuiani, C.; Bazzocchi, M.

    2002-01-01

    Background. The purpose of this study is to report our personal experience of 22 cases of ductal carcinoma in situ (DCIS) studied with magnetic resonance imaging (MRI). Patients and methods. From September 1995 to December 2001, 22 women diagnosed with DCIS lesions underwent contrast enhanced MRI within 7 days after mammographic examination. Dynamic MRI was performed with a 1 T system, using a three dimensional fast low angle shot (FLASH) pulse sequence before and after contrast media administration. We evaluated the morphologic features of the enhancement, the enhancement rate and the signal time intensity curve. Pathology was obtained in all cases. Results. The results of histopatological examination included: 15 DCIS and 7 DCIS with associated microinvasive component or microfoci of invasive ductal carcinoma (IDC). On MRI, 21 of 22 (95%) DCIS lesions showed contrast enhancement. Fourteen out of 15 pure DCIS lesions demonstrated respectively a low (3), undeterminate (5), and strong (6) enhancement. Morphologically, the enhancing lesion was focal in 7, segmental in 4, and with linear branching in 3 cases. Wash out was found in 4 cases, plateau curve in 8 and Type I curve in 2 cases. Multifocality was present in 5 cases. All DCIS with associated microinvasion demonstrated contrast enhancement: 1/7 cases showed a low enhancement, 2/7 showed an indeterminate enhancement and 4/7 showed a strong enhancement. Morphologically, the enhancing lesion was focal in 3/9, segmental in 5 and with linear branching in 1 case. The wash out was demonstrated in 3/7 cases, plateau curve in 3 and Type 1 curve in 1 case. Multifocality was present in 3 cases. Conclusions. In conclusion, the sensitivity of MRI for DCIS detection is lower than that achieved for invasive breast cancer; however, contrast-enhanced MRI can depict foci of DCIS that are mammographically occult. The MRI technique is of complementary value for a better description of tumor size and detection of additional

  7. Contrast agents for MRI

    International Nuclear Information System (INIS)

    Bonnemain, B.

    1994-01-01

    Contrast agents MRI (Magnetic Resonance Imaging) have been developed to improve the diagnostic information obtained by this technic. They mainly interact on T1 and T2 parameters and increase consequently normal to abnormal tissues contrast. The paramagnetic agents which mainly act on longitudinal relaxation rate (T1) are gadolinium complexes for which stability is the main parameter to avoid any release of free gadolinium. The superparamagnetic agents that decrease signal intensity by an effect on transversal relaxation rate (T2) are developed for liver, digestive and lymph node imaging. Many area of research are now opened for optimal use of present and future contrast agents in MRI. (author). 28 refs., 4 tabs

  8. MRI of vaginal conditions

    International Nuclear Information System (INIS)

    Lopez, C.; Balogun, M.; Ganesan, R.; Olliff, J.F.

    2005-01-01

    Magnetic resonance imaging (MRI) has become an important part of the assessment of suspected vaginal pathology. This pictorial review demonstrates the MRI features and some of the histopathological findings of a variety of vaginal conditions. These may be congenital (total vaginal agenesis, partial vaginal agenesis, longitudinal vaginal septum, transverse vaginal septum), benign (Bartholin's cyst, diffuse vaginal inflammation, invasive endometriosis, ureterovaginal fistula, post-surgical appearances with the formation of a neovagina and adhesions) or malignant, usually due to extension or recurrence from another pelvic malignancy. In this paper, examples of the above are described and illustrated together with examples of the much rarer primary vaginal malignancies

  9. MRI of vaginal conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, C. [Department of Radiology, Birmingham Women' s Hospital, Birmingham (United Kingdom)]. E-mail: carolina.lopez@bwhct.nhs.uk; Balogun, M. [Department of Radiology, Birmingham Women' s Hospital, Birmingham (United Kingdom); Ganesan, R. [Department of Histopathology, Birmingham Women' s Hospital, Birmingham (United Kingdom); Olliff, J.F. [University Hospital Birmingham, Birmingham (United Kingdom)

    2005-06-01

    Magnetic resonance imaging (MRI) has become an important part of the assessment of suspected vaginal pathology. This pictorial review demonstrates the MRI features and some of the histopathological findings of a variety of vaginal conditions. These may be congenital (total vaginal agenesis, partial vaginal agenesis, longitudinal vaginal septum, transverse vaginal septum), benign (Bartholin's cyst, diffuse vaginal inflammation, invasive endometriosis, ureterovaginal fistula, post-surgical appearances with the formation of a neovagina and adhesions) or malignant, usually due to extension or recurrence from another pelvic malignancy. In this paper, examples of the above are described and illustrated together with examples of the much rarer primary vaginal malignancies.

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... interfere with the magnetic field of the MRI unit, metal and electronic items are not allowed in ... does the equipment look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms that ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... women should not have this exam in the first three to four months of pregnancy unless the ... not to have an MRI exam during the first trimester unless medically necessary. MRI may not always ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... room. In addition to affecting the MRI images, these objects can become projectiles within the MRI scanner ... may cause you and/or others nearby harm. These items include: jewelry, watches, credit cards and hearing ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older open ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... MRI an invaluable tool in early diagnosis and evaluation of many conditions, including tumors. MRI enables the ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... used in MRI exams is less likely to produce an allergic reaction than the iodine-based contrast ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... used in tattoos may contain iron and could heat up during an MRI scan, but this is ... imaging based on the electrical activity of the heart, such as electrocardiography (EKG). MRI generally is not ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... medically necessary. MRI may not always distinguish between cancer tissue and fluid, known as edema . MRI typically ... Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association top ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ... than 30 minutes from the onset of symptoms. Risks The MRI examination poses almost no risk to ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older open MRI units may not provide this same image quality. Certain types of exams cannot be performed using ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI examination poses almost no risk to the average patient when appropriate safety guidelines are followed. If ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... as severe kidney disease, may prevent you from being given gadolinium contrast for an MRI. If you ... of time after placement (usually six weeks) before being safe for MRI examinations. Examples include but are ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... This detail makes MRI an invaluable tool in early diagnosis and evaluation of many conditions, including tumors. ... information. MRI can detect stroke at a very early stage by mapping the motion of water molecules ...

  10. Quality assurance in functional MRI

    DEFF Research Database (Denmark)

    Liu, Thomas T; Glover, Gary H; Mueller, Bryon A

    2015-01-01

    Over the past 20 years, functional magnetic resonance imaging (fMRI) has ben- efited greatly from improvements in MRI hardware and software. At the same time, fMRI researchers have pushed the technical limits of MRI systems and greatly in- fluenced the development of state-of-the-art systems...... consistent data throughout the course of a study, and consistent stability across time and sites is needed to allow data from different time periods or acquisition sites to be optimally integrated....

  11. Less Confusion in Diffusion MRI

    NARCIS (Netherlands)

    Tax, CMW

    2016-01-01

    With its unique ability to investigate tissue architecture and microstructure in vivo, diffusion MRI (dMRI) has gained tremendous interest and the society has been continuously triggered to develop novel dMRI image analysis approaches. With the overwhelming amount of strategies currently available

  12. MRI in subacute combined degeneration

    International Nuclear Information System (INIS)

    Murata, S.; Naritomi, H.; Sawada, T.

    1994-01-01

    Neuropathological studies show the main lesions to be in the posterior and lateral columns. Recent progress in MRI has made it possible to clarify the lesions of many neutrological diseases. However, there has only been one report of the lesions of SCD shown definitely on MRI. We report a typical case of the disease, with lesions shown clearly on MRI. (orig./MG)

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... to prepare your child for the sedation or anesthesia. Alternatively, certain pediatric facilities have child life personnel who can work with younger children to help avoid the need for sedation or anesthesia. They prepare the children for MRI by showing ...

  14. Combined PET/MRI

    DEFF Research Database (Denmark)

    Bailey, D. L.; Pichler, B. J.; Gückel, B.

    2015-01-01

    This paper summarises key themes and discussions from the 4th international workshop dedicated to the advancement of the technical, scientific and clinical applications of combined positron emission tomography (PET)/magnetic resonance imaging (MRI) systems that was held in Tübingen, Germany, from...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... types of clips used for brain aneurysms some types of metal coils placed within blood vessels nearly all cardiac defibrillators and pacemakers You ... a preferred imaging test. MR imaging can assess blood flow without ... the opening of certain types of MRI machines. The presence of an implant ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of MRI ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... or anesthesia. Alternatively, certain pediatric facilities have child life personnel who can work with younger children to help avoid the need ... MRI units may not provide this same image quality. Certain types of exams cannot be ... work? Unlike conventional x-ray examinations and computed tomography ( ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... have allergies of any kind, such as an allergy to iodine or x-ray contrast material, drugs, food, or the environment, or if you have asthma. The contrast material most commonly used for an MRI exam contains a metal ... in patients with iodine contrast allergy. It is far less common for a patient ...

  20. Acute epiglottitis: MRI

    International Nuclear Information System (INIS)

    Ozanne, A.; Marsot-Dupuch, K.; Ducreux, D.; Lasjaunias, P.; Meyer, B.

    2004-01-01

    We report the MRI findings in an adult with epiglottitis. There was thickening of the epiglottis and left aryepiglottic fold. Management of this life-threatening condition requires imaging only when the diagnosis is uncertain or when an abscess or other complication is suspected. (orig.)

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... a mild sedative prior to your scheduled examination. Infants and young children usually require sedation or anesthesia to complete an MRI exam without moving. Whether a child requires sedation depends on the child's age, intellectual development and the type of exam. Moderate and conscious ...

  2. Hippocampal malrotation: MRI findings

    International Nuclear Information System (INIS)

    Yanez, Paulina; Martinez, Adriana; Romero, Carlos; Lopez, Miriam; Zaffaroni, Alejandra; Lopez, Adriana

    2001-01-01

    Purpose: To demonstrate the common features of hippocampus malrotation in patients with epilepsy by volumetric and high-resolution MRI. Material and methods: MRI study was performed in 5 patients (2 females and 3 males) ages ranged between 6-41 years (average: 25 years), all of them with epilepsy diagnosis. MRI was performed with a 1.5 T (GE Signa). The epilepsy protocol include sagittal T1, axial T1 and T2, coronal FLAIR, coronal T2 (high-resolution) and volumetric 3D SPGR IR 1.5 mm thick sequences. Results: The common features found in all patients were: a) Incomplete inversion and round configuration of the hippocampus; b) Unilateral affectation; c) Variable affectation of the hippocampus; d) Normal signal intensity; e) Modification of the inner structure of the hippocampus; f) Abnormal angularity of the collateral sulcus; g) Abnormal position and size of the fornix; h) Normal size of the temporal lobe; and i) Enlargement of the temporal horn with particular configuration. Conclusion: Hippocampus malrotation is a malformation that should be included in the differential diagnosis of the epilepsy patients. MRI provides accurate information for the diagnosis. (author)

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... Imaging (MRI) - Chest Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... Whether a child requires sedation depends on the child's age, intellectual development and the type of exam. Moderate and conscious ... intercom. Many MRI centers allow a friend or parent to stay in the room as long as they are also ... will be given appropriately sized earplugs or headphones ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... bear denotes child-specific content. Related Articles and Media MR ... Images related to Magnetic Resonance Imaging (MRI) - Chest Sponsored ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... about pregnancy and MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want to ask your physician for a prescription for a mild sedative prior to your scheduled examination. Infants and young children usually require sedation or anesthesia to complete an ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... to have an allergy to a gadolinium-based contrast agent used for MRI than the iodine-containing contrast ... more information on adverse reactions to gadolinium-based contrast agents, please consult the ACR Manual on Contrast Media . ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... which they come. The MR scanner captures this energy and creates a picture of the tissues scanned based on this information. The magnetic field is produced by passing an electric current through wire coils in most MRI units. ...

  9. Fetal MRI; Fetales MRT

    Energy Technology Data Exchange (ETDEWEB)

    Blondin, D. [Inst. fuer Diagn. Radiologie, Uniklinikum Duesseldorf (Germany); Turowski, B. [Inst. fuer Diagn. Radiologie, Neuroradiologie, Uniklinikum Duesseldorf (Germany); Schaper, J. [Inst. fuer Diagn. Radiologie, Kinderradiologie, Uniklinikum Duesseldorf (Germany)

    2007-02-15

    Ultrasonography is the method of choice for prenatal malformation screening, but it does not always provide sufficient information for correct diagnosis or adequate abnormality evaluation. Fetal MRI is increasingly being used to complete sonographic findings. It was initially used for evaluation of cerebral abnormalities but is increasingly being applied to other fetal areas. In vivo investigation of fetal brain maturation has been enhanced by MRI. An adequate analysis of fetal chest and abdomen can be achieved with fast T2-, T1-weighted and diffusion-weighted imaging (DWI). The advantages include the great field of view and the excellent soft tissue contrast. This allows correct diagnosis of congenital diaphragmatic hernia and evaluation of the consequences on pulmonary growth. Other pulmonary malformations, such as cystic adenomatoid malformation, sequestration and brochogenic cysts, can also be easily identified. Renal position can be quickly determined using DWI sequences and renal agenesia can be easily diagnosed with only one sequence. Prenatal MRI is virtually as effective as postnatal examination, dispenses with transport of a potentially very ill newborn, and provides logistic advantages. Therefore, prenatal MRI is useful for adequate postnatal treatment of newborns with malformations. (orig.)

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will be necessary to perform a blood test to determine whether the kidneys are functioning adequately. Women should always inform their physician or technologist if ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... complete an MRI exam without moving. Whether a child requires sedation depends on the child's age, intellectual development and the type of exam. ... should be available during the exam for your child's safety. You will be given special instructions for ...

  12. MRI in suspected appendicitis

    NARCIS (Netherlands)

    Leeuwenburgh, M.M.N.

    2014-01-01

    Dit proefschrift richt zich op de optimalisatie van beeldvormende diagnostiek bij patiënten met een klinische verdenking op appendicitis, waarbij het gebruik van ‘magnetic resonance imaging’ (MRI) wordt verkend. Het proefschrift omvat de resultaten van de OPTIMAP-studie (OPTimisation of IMaging

  13. Simultaneous MRI and PET imaging of a rat brain

    International Nuclear Information System (INIS)

    Raylman, Raymond R; Majewski, Stan; Lemieux, Susan K; Velan, S Sendhil; Kross, Brian; Popov, Vladimir; Smith, Mark F; Weisenberger, Andrew G; Zorn, Carl; Marano, Gary D

    2006-01-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI will allow the correlation of form with function. Our group is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode. Each MRI-PET detector module consists of an array of LSO detector elements coupled through a long fibre optic light guide to a single Hamamatsu flat panel position-sensitive photomultiplier tube (PSPMT). The use of light guides allows the PSPMTs to be positioned outside the bore of a 3T MRI scanner where the magnetic field is relatively small. To test the device, simultaneous MRI and PET images of the brain of a male Sprague Dawley rat injected with FDG were successfully obtained. The images revealed no noticeable artefacts in either image set. Future work includes the construction of a full ring PET scanner, improved light guides and construction of a specialized MRI coil to permit higher quality MRI imaging

  14. Simultaneous MRI and PET imaging of a rat brain

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States); Majewski, Stan [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Lemieux, Susan K [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States); Velan, S Sendhil [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States); Kross, Brian [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Popov, Vladimir [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Smith, Mark F [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Weisenberger, Andrew G [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Zorn, Carl [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Marano, Gary D [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States)

    2006-12-21

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI will allow the correlation of form with function. Our group is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode. Each MRI-PET detector module consists of an array of LSO detector elements coupled through a long fibre optic light guide to a single Hamamatsu flat panel position-sensitive photomultiplier tube (PSPMT). The use of light guides allows the PSPMTs to be positioned outside the bore of a 3T MRI scanner where the magnetic field is relatively small. To test the device, simultaneous MRI and PET images of the brain of a male Sprague Dawley rat injected with FDG were successfully obtained. The images revealed no noticeable artefacts in either image set. Future work includes the construction of a full ring PET scanner, improved light guides and construction of a specialized MRI coil to permit higher quality MRI imaging.

  15. MRI of interstitial lung diseases. What is possible?

    International Nuclear Information System (INIS)

    Biederer, J.; Wielpuetz, M.O.; Jobst, B.J.; Dinkel, J.

    2014-01-01

    Magnetic resonance imaging (MRI) of the lungs is becoming increasingly appreciated as a third diagnostic imaging modality besides chest x-ray and computed tomography (CT). Its value is well acknowledged for pediatric patients or for scientific use particularly when radiation exposure should be strictly avoided. However, the diagnosis of interstitial lung disease is the biggest challenge of all indications. The objective of this article is a summary of the current state of the art for diagnostic MRI of interstitial lung diseases. This article reflects the results of a current search of the literature and discusses them against the background of the authors own experience with lung MRI. Due to its lower spatial resolution and a higher susceptibility to artefacts MRI does not achieve the sensitivity of CT for the detection of small details for pattern recognition (e.g. fine reticulation and micronodules) but larger details (e.g. coarse fibrosis and honeycombing) can be clearly visualized. Moreover, it could be shown that MRI has the capability to add clinically valuable information on regional lung function (e.g. ventilation, perfusion and mechanical properties) and inflammation with native signal and contrast dynamics. In its present state MRI can be used for comprehensive cardiopulmonary imaging in patients with sarcoidosis or for follow-up of lung fibrosis after initial correlation with CT. Far more indications are expected when the capabilities of MRI for the assessment of regional lung function and activity of inflammation can be transferred into robust protocols for clinical use. (orig.) [de

  16. [Role of MRI for detection and characterization of pulmonary nodules].

    Science.gov (United States)

    Sommer, G; Koenigkam-Santos, M; Biederer, J; Puderbach, M

    2014-05-01

    Due to physical and technical limitations, magnetic resonance imaging (MRI) has hitherto played only a minor role in image-based diagnostics of the lungs. However, as a consequence of important methodological developments during recent years, MRI has developed into a technically mature and clinically well-proven method for specific pulmonary questions. The purpose of this article is to provide an overview on the currently available sequences and techniques for assessment of pulmonary nodules and analyzes the clinical significance according to the current literature. The main focus is on the detection of lung metastases, the detection of primary pulmonary malignancies in high-risk individuals and the differentiation between pulmonary nodules of benign and malignant character. The MRI technique has a sensitivity of approximately 80 % for detection of malignant pulmonary nodules compared to the reference standard low-dose computed tomography (CT) and is thus somewhat inferior to CT. Advantages of MRI on the other hand are a higher specificity in differentiating malignant and benign pulmonary nodules and the absence of ionizing radiation exposure. A systematic use of MRI as a primary tool for detection and characterization of pulmonary nodules is currently not recommended due to insufficient data. The diagnostic potential of MRI for early detection and staging of malignant pulmonary diseases, however, seems promising. Therefore, further evaluation of MRI as a secondary imaging modality in clinical trials is highly warranted.

  17. MRI of the cardiomyopathies

    International Nuclear Information System (INIS)

    Di Cesare, Ernesto

    2001-01-01

    We examined the potentialities of Magnetic resonance imaging (MRI) in the evaluation of the main cardiomyopathies: hypertrophic, dilated, restrictive and arrhythmogenic right ventricular. The hypertrophic cardiomyopathy is generally adequately investigated by echocardiography, that well defines the myocardial thickening and the obstruction of the left ventricular output. However, by echocardiography we still have difficulties in the evaluation of the apex of the left ventricle and the right ventricle involvement. MRI provides a complete evaluation of the heart with a clear evidence also of the echocardiographic dark zones by means of a clear evidence of the apex of the right ventricle. The dilated form is also well investigated by MRI that provides a clear evaluation of the volumes, mass and ejection fraction by means of the 3D analysis including conditions of the ventricular remodelling. Moreover, this technique helps in the differential diagnosis of acute myocarditis. In the acute phase of myocarditis (first 2 weeks), in fact, the myocardium produces high signal intensity on the T2 weighted sequences due to the presence of oedema. The third form of cardiomyopathy is the restrictive one, characterised by reduced diastolic filling and diastolic volume, normality of the systolic function and parietal thickness, interstitial fibrosis and enlargement of both atria. The mean potentiality of MRI is related to the differential diagnosis with constrictive pericarditis. Only in the former, the pericardium appears irregularly thickened with areas exceeding 4 mm of pericardial thickness. Finally, the right ventricular arrhythmogenic cardiomyopathy represents the main indication to MRI evaluation. With this imaging modality we are can obtain a clear morpho-functional evaluation of the right ventricle and distinguish the intramyocardial adipose substitution characterised by areas of high signal in the myocardium

  18. MRI in diagnostic evaluation of osteomyelitis in children

    International Nuclear Information System (INIS)

    Stoever, B.; Sigmund, G.; Langer, M.; Brandis, M.

    1994-01-01

    Several MRI investigations for detecting or excluding acute and non-post-traumatic chronic osteomyelitis were performed in 31 children, osteomyelitis was evident in 21 patients. The sensitivity of MRI for osteomyelitis was 90%, and specificity was 100%. In children with confirmed osteomyelitis 23 follow-up investigations were carried out in order to evaluate duration of the medullary edema. In uncomplicated cases only treated by antibiotics edema regression was evident after 4 weeks and completed after 12-16 weeks. In cases in whom extended concomitant soft-tissue infection was depicted regression of edema was prolonged independent of surgical intervention. The study reveals that at onset of acute osteomyelitis in children MRI can replace technetium 99m-labeled scintigraphy and reduce plain-film investigations. The results support the usefulness of MRI in discrimination of isolated soft-tissue infection and noninfectious diseases of bone. (orig.)

  19. MRI diagnosis of intracranial tuberculosis (73 cases report)

    International Nuclear Information System (INIS)

    Zeng Qingyong; Li Xin; He Zhihui; Cheng Chuanhu; Deng Kaijun; Deng Ming

    2008-01-01

    Objective: To assess the MRI features, classification and diagnostic value for intracranial tuberculosis. Methods MRI findings of 73 patients suffering from intracranial tuberculosis proved by pathology or clinic were analyzed respectively. Among the total 73 patients, 39 cases were tuberculosis meningitis, 12 cases simple intracranial tuberculoma, while 22 cases were tuberculoma combining with meningitis. Results: The MRI features of tuberculous meningitis are cerebral infarction, hydrocephalus, abnormal meningeal and cerebral cistern enhancement. 12 cases mature tuberculoma demon- strated typical features with high or low density on T 2 WI images and ring contrast enhancement; 22 cases non-mature tuberculoma showed focal nodular contrast enhancement with evident cerebral edema. FLAIR is more sensitive to find out focus than T 2 WI. Small lesions could be showed definitively by contrast-enhanced scan. Conclusion: MRI possess typical features in the diagnosis of intracranial tuberculosis. It plays an important role in evaluating location, range, classification of intracranial tuberculosis, and is helpful to clinical treatment. (authors)

  20. Combined PET/MRI in cerebral and paediatric diagnostics

    International Nuclear Information System (INIS)

    Pfluger, T.; Vollmar, C.; Porn, U.; Schmid, R.; Dresel, S.; Leinsinger, G.; Schmid, I.; Winkler, P.; Fischer, S.; Hahn, K.

    2002-01-01

    The aim of this overview is presentation of MRI and PET as synergistic modalities for combined analysis of morphology and function. For operative planning in epilepsy surgery, definition of the epileptogenic focus based on functional PET diagnostics and morphological MRI is decisive. For staging and follow-up examinations in oncology, MRI should be complemented by PET for the assessment of tumor vitality. In paediatric oncology patients we could demonstrate a therapy relevant increase of sensitivity/specificity with combined PET/MRI in contrast to single modalities. In the brain, full spectrum of digital image registration and three-dimensional reconstruction should be used. In extracranial cases, image fusion is disturbing due to a partial loss of image information of single modalities by the fusion process. (orig.) [de

  1. SPECT and MRI in the diagnosis of epilepsy

    International Nuclear Information System (INIS)

    Gruenwald, F.; Biersack, H.J.; Bockisch, A.; Elger, C.E.; Durwen, H.F.; Penin, H.

    1989-01-01

    This study presents the results obtained using SPECT and MRI in epilepsy - mainly based on presurgical investigation in therapy-resistant cases of temporal lobe epilepsy. MRI was positive in 61% of 102 examined patients, SPECT was positive in 84%. In 46 patients with temporal lobe epilepsy subjected to partial temporal lobectomy was performed later on there was agreement of the results obtained with regard to the lateralisation in 74%. Although MRI, due to its sensitivity is superior to CT in diagnosis of epilepsy, CT should be performed in any case because some morphological changes - especially small arteriovenous malformations - are only seen in CT. MRI and SPECT should be considered as two complementary methods in epilepsy diagnosis, serving to evaluate morphology and function. A definite statement as to the predictive value of both methods remains to be made depending on a comparison of the results with the postoperative outcome referring to seizure frequency and cognitive function. (orig.) [de

  2. Multiparametric MRI in detection and staging of prostate cancer

    DEFF Research Database (Denmark)

    Boesen, Lars

    2017-01-01

    progression, the diagnosis and subsequent treatment planning can be challenging. The current diagnostic approach with PSA testing and digital rectal examination followed by transrectal ultrasound biopsies (TRUS-bx) lack in both sensitivity and specificity in PCa detection and offers limited information about......-MRI-targeted biopsies (mp-MRI-bx) under TRUS-guidance of any mp-MRI-suspicious lesion not hit on systematic TRUS-bx. Study II included patients with clinically localised PCa (cT1-T2) determined by digital rectal examination and/or TRUS and scheduled for radical prostatectomy (RP). Mp-MRI was performed prior to RP...... divided by ADCbenign). The ADC measurements (ADCtumour and ADCratio values) were correlated with the Gleason score (GS) from each tumour foci. RESULTS: Eighty-three patients were included in study I. PCa was found in 39/83 (47%) and both the PIRADS summation score and the over-all Likert classification...

  3. Integrated 18F-FDG PET/MRI compared to MRI alone for identification of local recurrences of soft tissue sarcomas: a comparison trial

    Energy Technology Data Exchange (ETDEWEB)

    Erfanian, Youssef; Grueneisen, Johannes; Wetter, Axel; Forsting, Michael; Umutlu, Lale [University Hospital Essen, University of Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Kirchner, Julian [University Hospital Dusseldorf, University of Dusseldorf, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Podleska, Lars Erik [University Hospital Essen, University of Duisburg-Essen, Sarcoma Surgery Division, Department of General-, Visceral- and Transplantation Surgery, Essen (Germany); Bauer, Sebastian [University Hospital Essen, University of Duisburg-Essen, Division of Solid Tumor Translational Oncology, Department of Medical Oncology, West German Cancer Center, Essen (Germany); Poeppel, Thorsten; Herrmann, Ken [University Hospital Essen, University of Duisburg-Essen, Clinic for Nuclear Medicine, Essen (Germany)

    2017-10-15

    To assess and compare the diagnostic accuracy of PET/MRI and MRI alone for the detection of local recurrences of soft tissue sarcomas (STS) after initial surgical resection of the primary tumors. A total of 41 patients with clinically suspected tumor relapse of STS underwent an {sup 18}F-FDG-PET/MRI examination for assessment of local recurrence. Two experienced physicians interpreted the MRI data and subsequently the PET/MRI datasets in two separate reading sessions and were instructed to identify potential local tumor recurrences. Additionally, the diagnostic confidence in each reading for the identification of malignant lesions was determined. A McNemar test was applied to test for differences of both ratings and a Wilcoxon signed-rank test was used to identify differences of the confidence levels. Histopathological verification and follow-up imaging were applied for standard of reference. Tumor relapse was present in 27/41 patients. Calculated sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for the detection of local tumor recurrence was 82%, 86%, 92%, 71% and 83% for MRI, and 96%, 79%, 90%, 92% and 90% for PET/MRI (p > 0.05). Furthermore, PET/MRI showed significantly higher confidence levels (p < 0.05) for the determination of malignant lesions. Our results endorse {sup 18}F-FDG PET/MRI to be an excellent imaging method in the evaluation of recurrent STS after surgical excision, yielding superior tumor detection when compared to MRI alone. (orig.)

  4. Effect of patient age on accuracy of primary MRI signs of long head of biceps tearing and instability in the shoulder. An MRI-arthroscopy correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Borrero, Camilo G.; Costello, Joanna; Vyas, Dharmesh [University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Bertolet, Marnie [University of Pittsburgh School of Medicine, Pittsburgh, PA (United States)

    2018-02-15

    To determine the effect of patient age on the accuracy of primary MRI signs of long head of biceps (LHB) tendon tearing and instability in the shoulder using arthroscopy as a reference standard. Subjects with MRI studies and subsequent arthroscopy documenting LHB tendon pathology were identified and organized into three age groups (18-40, 41-60, 61-87). Normal and tendinopathic tendons were labeled grade 0, partial tears grade 1 and full tears grade 2. Two radiologists blinded to arthroscopic data graded MRI studies independently. Prevalence of disease, MRI accuracy for outcomes of interest, and inter-reader agreement were calculated. Eighty-nine subjects fulfilled inclusion criteria with 36 grade 0, 36 grade 1 and 17 grade 2 tendons found at arthroscopy. MRI sensitivity, regardless of age, ranged between 67-86% for grade 0, 72-94% for grade 1 and 82-94% for grade 2 tendons. Specificity ranged between 83-96% for grade 0, 75-85% for grade 1 and 99-100% for grade 2 tendons. MRI accuracy for detection of each LHB category was calculated for each age group. MRI was found to be least sensitive for grade 0 and 1 LHB tendons in the middle-aged group with sensitivity between 55-85% for grade 0 and 53-88% for grade 1 tendons. Agreement between MRI readers was moderate with an unweighted kappa statistic of 62%. MRI accuracy was moderate to excellent and agreement between MRI readers was moderate. MRI appears to be less accurate in characterizing lower grades of LHB tendon disease in middle-aged subjects. (orig.)

  5. MRI of chemical reactions and processes.

    Science.gov (United States)

    Britton, Melanie M

    2017-08-01

    As magnetic resonance imaging (MRI) can spatially resolve a wealth of molecular information available from nuclear magnetic resonance (NMR), it is able to non-invasively visualise the composition, properties and reactions of a broad range of spatially-heterogeneous molecular systems. Hence, MRI is increasingly finding applications in the study of chemical reactions and processes in a diverse range of environments and technologies. This article will explain the basic principles of MRI and how it can be used to visualise chemical composition and molecular properties, providing an overview of the variety of information available. Examples are drawn from the disciplines of chemistry, chemical engineering, environmental science, physics, electrochemistry and materials science. The review introduces a range of techniques used to produce image contrast, along with the chemical and molecular insight accessible through them. Methods for mapping the distribution of chemical species, using chemical shift imaging or spatially-resolved spectroscopy, are reviewed, as well as methods for visualising physical state, temperature, current density, flow velocities and molecular diffusion. Strategies for imaging materials with low signal intensity, such as those containing gases or low sensitivity nuclei, using compressed sensing, para-hydrogen or polarisation transfer, are discussed. Systems are presented which encapsulate the diversity of chemical and physical parameters observable by MRI, including one- and two-phase flow in porous media, chemical pattern formation, phase transformations and hydrodynamic (fingering) instabilities. Lastly, the emerging area of electrochemical MRI is discussed, with studies presented on the visualisation of electrochemical deposition and dissolution processes during corrosion and the operation of batteries, supercapacitors and fuel cells. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  6. Short-Term changes on MRI predict long-Term changes on radiography in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Peterfy, Charles; Strand, Vibeke; Tian, Lu

    2017-01-01

    Objective In rheumatoid arthritis (RA), MRI provides earlier detection of structural damage than radiography (X-ray) and more sensitive detection of intra-Articular inflammation than clinical examination. This analysis was designed to evaluate the ability of early MRI findings to predict subsequent...

  7. Infantile hypopituitarism: etiological variability evidenced by MRI

    International Nuclear Information System (INIS)

    Smet, M.H.; Zegher, F. de; Vanderschueren-Lodeweyckx, M.; Marchal, G.

    1992-01-01

    In this study, magnetic resonance imaging (MRI) was performed to document potentially present morphostructural abnormalities of the hypothalamopituitary region in seven infants (age 0-21 months) who presented very early in life with clinical and biochemical evidence of hypopituitarism. Four infants had associated congenital cerebro-facial malformations. The following anatomical abnormalities were identified in variable combinations: ectopic neurohypophysis, absence of the pituitary stalk, extreme elongation of the pituitary stalk, aplasia of the anterior pituitary lobe and no identification of the hypothalamopituitary complex. MRI proved to be very sensitive in the identification of structural malformations of the hypothalamopituitary region in infants with or without cerebro-facial malformations. Although the magnetic resonance image does not appear to be a good predictor of endocrine dysfunction, it provides us more insight into the precise aetiology of this disorder and may be therefore of diagnostic, prognostic and therapeutic importance. (orig.)

  8. MRI and HMPAO-SPECT in the diagnosis of epilepsy

    International Nuclear Information System (INIS)

    Bokisch, A.; Gruenwald, F.; Elger, C.E.; Kaiser, W.A.; Biersack, H.J.

    1992-01-01

    Eighty-three patients suffering from intractable epilepsy were investigated by magnetic resonance imaging (MRI) and by HMPAO-SPECT during presurgical evaluation. MRI was proven to be most sensitive concerning the detection of focal lesions. Acquisition of thin slices and high signal/noise ratios are prerequisites for optimal sensitivity, the use of Gd-DTPA, in addition, increases the reliability slightly. Histological findings were available in 21 patients and in all cases of focal lesions without prior surgery, malignancy was detected or excluded correctly. The sensitivity was reduced, however, in the 4 patients with recurrency of astrocytoma. 2 cases were missed. Quantitative evaluation of signal intensities in the amygdala/hippocampal region or of the signal dynamics after contrast media application were not helpful in patients without focal lesion. In these patients no reliable criterium to determine the side of the focus with MRI investigations could be established. HMPAO-SPECT investigations were found to be complementary to MRI. In 19 of 36 patients without focal lesions the lateralisation was feasible by scintigraphy. In addition a correlation between the volume asymmetry of the temporal horns detected by MRI and the scintigraphic finding was established. The statistical proven correlation between the unilateral dilatation of the temporal horn and relative hypoperfusion is too weak, however, to imply individual consequences. (orig.) [de

  9. Bladder cancer: Evaluation of staging accuracy using dynamic MRI

    International Nuclear Information System (INIS)

    Rajesh, A.; Sokhi, H.K.; Fung, R.; Mulcahy, K.A.; Bankart, M.J.G.

    2011-01-01

    Aim: To assess the accuracy of magnetic resonance imaging (MRI) in staging bladder cancer and to assess whether dynamic gadolinium-enhanced sequences have any added benefit in staging. Materials and methods: Over a 22 month period, the MRI findings of 100 consecutive patients with histologically proven transitional cell carcinoma (TCC) of the bladder were reviewed. The T stage was assessed independently on T2-weighted imaging alone and in combination with gadolinium-enhanced MRI. The final histological diagnosis was considered the reference standard. Statistical analysis was performed to ascertain stage-by-stage accuracy. Accuracy of MRI in differentiating superficial (≤T1) from invasive (≥T2) and in differentiating organ-confined (≤T2) from non-organ-confined (≥T3) disease was assessed. Results: On a stage-by-stage basis, tumours were correctly staged using MRI in 63% of patients (observed agreement = 0.63, weighted kappa = 0.57). The sensitivity and specificity of MRI to differentiate between superficial (≤T1) from invasive (≥T2) disease was 78.2 and 93.3%. The observed agreement for this group was 85% (kappa = 70%; p < 0.0001). The sensitivity and specificity of MRI to differentiate between organ-confined (≤T2) from non-organ confined (≥T3) disease was 90.5 and 60%. The observed agreement for this group was 89% (kappa = 30%; p < 0.01). Gadolinium-enhanced images improved staging in only three patients. Conclusion: In the present study MRI was found to be a moderately accurate tool in assessing the T stage. Agreement on a stage-by-stage basis was good. Agreement for differentiating between non-invasive versus muscle-invasive disease was good and that for organ-confined versus non-organ-confined disease was fair. Routine use of gadolinium-enhanced images is not routinely required.

  10. Bladder cancer: Evaluation of staging accuracy using dynamic MRI

    Energy Technology Data Exchange (ETDEWEB)

    Rajesh, A., E-mail: arajesh27@hotmail.com [Department of Radiology, University Hospitals of Leicester NHS Trust, Leicester General Hospital (United Kingdom); Sokhi, H.K.; Fung, R.; Mulcahy, K.A. [Department of Radiology, University Hospitals of Leicester NHS Trust, Leicester General Hospital (United Kingdom); Bankart, M.J.G. [Department of Health Sciences, University of Leicester, Leicester (United Kingdom)

    2011-12-15

    Aim: To assess the accuracy of magnetic resonance imaging (MRI) in staging bladder cancer and to assess whether dynamic gadolinium-enhanced sequences have any added benefit in staging. Materials and methods: Over a 22 month period, the MRI findings of 100 consecutive patients with histologically proven transitional cell carcinoma (TCC) of the bladder were reviewed. The T stage was assessed independently on T2-weighted imaging alone and in combination with gadolinium-enhanced MRI. The final histological diagnosis was considered the reference standard. Statistical analysis was performed to ascertain stage-by-stage accuracy. Accuracy of MRI in differentiating superficial ({<=}T1) from invasive ({>=}T2) and in differentiating organ-confined ({<=}T2) from non-organ-confined ({>=}T3) disease was assessed. Results: On a stage-by-stage basis, tumours were correctly staged using MRI in 63% of patients (observed agreement = 0.63, weighted kappa = 0.57). The sensitivity and specificity of MRI to differentiate between superficial ({<=}T1) from invasive ({>=}T2) disease was 78.2 and 93.3%. The observed agreement for this group was 85% (kappa = 70%; p < 0.0001). The sensitivity and specificity of MRI to differentiate between organ-confined ({<=}T2) from non-organ confined ({>=}T3) disease was 90.5 and 60%. The observed agreement for this group was 89% (kappa = 30%; p < 0.01). Gadolinium-enhanced images improved staging in only three patients. Conclusion: In the present study MRI was found to be a moderately accurate tool in assessing the T stage. Agreement on a stage-by-stage basis was good. Agreement for differentiating between non-invasive versus muscle-invasive disease was good and that for organ-confined versus non-organ-confined disease was fair. Routine use of gadolinium-enhanced images is not routinely required.

  11. Comparison of {sup 18}F-FDG PET/MRI and MRI for pre-therapeutic tumor staging of patients with primary cancer of the uterine cervix

    Energy Technology Data Exchange (ETDEWEB)

    Sarabhai, Theresia; Wetter, Axel; Forsting, Michael; Umutlu, Lale; Grueneisen, Johannes [University Hospital Essen, University of Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Schaarschmidt, Benedikt M.; Kirchner, Julian [University Dusseldorf, Department of Diagnostic and Interventional Radiology, Medical Faculty, Dusseldorf (Germany); Aktas, Bahriye [University Hospital Essen, University of Duisburg-Essen, Department of Obstetrics and Gynecology, Essen (Germany); Ruhlmann, Verena; Herrmann, Ken [University Hospital Essen, University of Duisburg-Essen, Department of Nuclear Medicine, Essen (Germany)

    2018-01-15

    The aim of the present study was to assess and compare the diagnostic performance of integrated PET/MRI and MRI alone for local tumor evaluation and whole-body tumor staging of primary cervical cancers. In addition, the corresponding impact on further patient management of the two imaging modalities was assessed. A total of 53 consecutive patients with histopathological verification of a primary cervical cancer were prospectively enrolled for a whole-body 18F-FDG PET/MRI examination. Two experienced physicians analyzed the MRI data, in consensus, followed by a second reading session of the PET/MRI datasets. The readers were asked to perform a dedicated TNM staging in accordance with the 7th edition of the AJCC staging manual. Subsequently, the results of MRI and PET/MRI were discussed in a simulated interdisciplinary tumor board and therapeutic decisions based on both imaging modalities were recorded. Results from histopathology and cross-sectional imaging follow-up served as the reference standard. PET/MRI allowed for a correct determination of the T stage in 45/53 (85%) cases, while MRI alone enabled a correct identification of the tumor stage in 46/53 (87%) cases. In 24 of the 53 patients, lymph node metastases were present. For the detection of nodal-positive patients, sensitivity, specificity and accuracy of PET/MRI were 83%, 90% and 87%, respectively. The respective values for MRI alone were 71%, 83% and 77%. In addition, PET/MRI showed higher values for the detection of distant metastases than MRI alone (sensitivity: 87% vs. 67%, specificity: 92% vs. 90%, diagnostic accuracy: 91% vs. 83%). Among the patients with discrepant staging results in the two imaging modalities, PET/MRI enabled correct treatment recommendations for a higher number (n = 9) of patients than MRI alone (n = 3). The present results demonstrate the successful application of integrated PET/MRI imaging for whole-body tumor staging of cervical cancer patients, enabling improved treatment

  12. Impact of MRI on high grade Ductal Carcinoma Insitu (HG DCIS) management, are we using the full scope of MRI?

    Science.gov (United States)

    Hajaj, Mohamad; Karim, Ahmed; Pascaline, Sana; Noor, Lubna; Patel, Shivali; Dakka, Mahmoud

    2017-10-01

    Preoperative assessment of pure Ductal Carcinoma Insitu (DCIS) is essential in the surgical planning. The role of Magnetic resonance imaging (MRI) has long been debated. The impact of MRI on the management of High Grade (HG) DCIS was assessed, whether it accurately captures the true size of this entity in comparison to conventional imaging, and, if MRI use would reduce the number of re-excision surgery. Ninety-one consecutive patients with HG DCIS, who were identified from a prospectively collected data at Kettering General Hospital between April 2011 and December 2015. All patients had preoperative MRI scan in addition to the standard breast imaging. This was compared to a control group of consecutive patients (n=52) which was obtained from a period just before 2011. Impact on surgical planning and number of surgeries for each patient was compared. The size of HG DCIS estimated by MRI was compared to the final histological size. Secondary outcomes included change of initial surgical plan and detection of occult contralateral breast cancer. MRI group had 91 patients with median age of 63. Seventy percent of which presented through the screening program. The overall sensitivity of MRI to detect HG DCIS was 77% (70/91) with a false negative rate FNR of 23% (21/91). Therefore, 70 patients only were included in the data analysis. The control group included 52 screening patients with comparable baseline characteristics. Re-excision (or completion mastectomy) rates were higher in the control group 26% compared to 8% in the MRI group (P-value 0.012). MRI use correctly converted the initial plan of breast conservation to mastectomy in 9 patients (13%). Five patients had additional ipsilateral malignant features (7%).Occult contra lateral disease, was diagnosed in 2 patients (3%). This study suggests that MRI could be an important tool in reducing the re-excision rates in the surgical management of HG DCIS. Although still controversial, selective MRI imaging can be useful

  13. MRI of cardiovascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Kastler, Bruno [Centre Hospitalier Univ. Jean Minjoz, Besancon (France); Universite de Franche-Comte, Besancon (FR). Lab. I4S (Health, Innovation, Intervention, Imaging, Engineering); Centre Hospitalier Sherbrooke Univ., PQ (Canada). Dept. of Radiology

    2011-07-01

    MRI is a non-invasive and non-ionizing imaging modality that is perfectly suited for the diagnosis and follow-up of both pediatric and adult congenital heart disease. It provides a large field of view and has the unique ability to depict complex cardiac and vascular anatomy and to measure cardiac function and flow within one examination. MRI is the ideal complement to echocardiography whenever the information provided by the latter is limited. This book has been conceived as a self-teaching manual that will assist qualified radiologists, cardiologists, and pediatricians, as well as those in training. It is richly illustrated with numerous images and drawings that cover all usual and most unusual anomalies. The principal author, Professor Bruno Kastler, is head of radiology at Besancon University Hospital, France and is board certified in both radiology and cardiology. (orig.)

  14. MRI of cardiovascular malformations

    International Nuclear Information System (INIS)

    Kastler, Bruno; Universite de Franche-Comte, Besancon; Centre Hospitalier Sherbrooke Univ., PQ

    2011-01-01

    MRI is a non-invasive and non-ionizing imaging modality that is perfectly suited for the diagnosis and follow-up of both pediatric and adult congenital heart disease. It provides a large field of view and has the unique ability to depict complex cardiac and vascular anatomy and to measure cardiac function and flow within one examination. MRI is the ideal complement to echocardiography whenever the information provided by the latter is limited. This book has been conceived as a self-teaching manual that will assist qualified radiologists, cardiologists, and pediatricians, as well as those in training. It is richly illustrated with numerous images and drawings that cover all usual and most unusual anomalies. The principal author, Professor Bruno Kastler, is head of radiology at Besancon University Hospital, France and is board certified in both radiology and cardiology. (orig.)

  15. MRI of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Vahlensieck, M.

    2000-02-01

    Shoulder imaging is one of the major applications in musculoskeletal MRI. In order to analyze the images it is important to keep informed about anatomical and pathological findings and publications. In this article MRI technique, anatomy and pathology is reviewed. Technical considerations about MR sequences and examination strategy are only shortly discussed with emphasis on turbo spin echo and short T1 inversion recovery imaging. Basic anatomy as well as recent findings, including macroscopic aspects of the supraspinatus fat pad, composition of the supraspinatus muscle belly, and variability of the glenohumeral ligaments or coracoid ligament, are presented. Basic pathological conditions are described in detail, e. g. instability particularly problems in differentiating the various subtypes of labral pathology. Rotator cuff diseases are elucidated with emphasis on some rarer entities such as subscapularis calcifying tendinitis, coracoid impingement, chronic bursitis producing the double-line sign, prominent coraco-acromial ligament and the impingement due to an inflamed os acromiale. (orig.)

  16. Boomerang sign on MRI.

    Science.gov (United States)

    Hirsch, Karen G; Hoesch, Robert E

    2012-06-01

    Altered mental status and more subtle cognitive and personality changes after traumatic brain injury (TBI) are pervasive problems in patients who survive initial injury. MRI is not necessarily part of the diagnostic evaluation of these patients. Case report with relevant image and review of the literature. Injury to the corpus callosum is commonly described in traumatic brain injury; however, extensive lesions in the splenium are not well described. This image shows an important pattern of brain injury and demonstrates a common clinical syndrome seen in patients with corpus callosum pathology. Injury to the splenium of the corpus callosum due to trauma may be extensive and can cause significant neurologic deficits. MRI is important in the diagnostic evaluation of patients with cognitive changes after TBI.

  17. MRI of the shoulder

    International Nuclear Information System (INIS)

    Vahlensieck, M.

    2000-01-01

    Shoulder imaging is one of the major applications in musculoskeletal MRI. In order to analyze the images it is important to keep informed about anatomical and pathological findings and publications. In this article MRI technique, anatomy and pathology is reviewed. Technical considerations about MR sequences and examination strategy are only shortly discussed with emphasis on turbo spin echo and short T1 inversion recovery imaging. Basic anatomy as well as recent findings, including macroscopic aspects of the supraspinatus fat pad, composition of the supraspinatus muscle belly, and variability of the glenohumeral ligaments or coracoid ligament, are presented. Basic pathological conditions are described in detail, e. g. instability particularly problems in differentiating the various subtypes of labral pathology. Rotator cuff diseases are elucidated with emphasis on some rarer entities such as subscapularis calcifying tendinitis, coracoid impingement, chronic bursitis producing the double-line sign, prominent coraco-acromial ligament and the impingement due to an inflamed os acromiale. (orig.)

  18. Contrast-enhanced spectral mammography (CESM) versus MRI in the high-risk screening setting: patient preferences and attitudes.

    Science.gov (United States)

    Phillips, Jordana; Miller, Matthew M; Mehta, Tejas S; Fein-Zachary, Valerie; Nathanson, Audrey; Hori, Wendy; Monahan-Earley, Rita; Slanetz, Priscilla J

    Our study evaluates patient preferences toward screening CESM versus MRI. As part of a prospective study, high-risk patients had breast MRI and CESM. Patients completed an anonymous survey to evaluate preferences regarding the two modalities. 88% of participants completed the survey. 79% preferred CESM over MRI if the exams had equal sensitivity. 89% would be comfortable receiving contrast as part of an annual screening test. High-risk populations may accept CESM as a screening exam and may prefer it over screening MRI if ongoing trials demonstrate screening CESM to be clinically non-inferior MRI. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. MRI: Imaging of stomach

    International Nuclear Information System (INIS)

    Lam, W. W. M; Lee, J. S. W.; Ho, G.

    2007-01-01

    Full text: The study is to determine the optimal MRI bowel preparation regime for visualization of the stomach anatomy, Eight healthy volunteers were asked to take water, 75% barium and blueberry juice. The image quality and tolerance of different stomach distension regime were evaluated. Blueberry juice gave the best distension, but the signal intensity was not very homogeneous. Taking into account the image quality, tolerability and adverse effects, it is concluded that water is the most desirable oral contrast for MR stomach imaging

  20. MRI anatomy of schizophrenia.

    Science.gov (United States)

    McCarley, R W; Wible, C G; Frumin, M; Hirayasu, Y; Levitt, J J; Fischer, I A; Shenton, M E

    1999-05-01

    Structural magnetic resonance imaging (MRI) data have provided much evidence in support of our current view that schizophrenia is a brain disorder with altered brain structure, and consequently involving more than a simple disturbance in neurotransmission. This review surveys 118 peer-reviewed studies with control group from 1987 to May 1998. Most studies (81%) do not find abnormalities of whole brain/intracranial contents, while lateral ventricle enlargement is reported in 77%, and third ventricle enlargement in 67%. The temporal lobe was the brain parenchymal region with the most consistently documented abnormalities. Volume decreases were found in 62% of 37 studies of whole temporal lobe, and in 81% of 16 studies of the superior temporal gyrus (and in 100% with gray matter separately evaluated). Fully 77% of the 30 studies of the medial temporal lobe reported volume reduction in one or more of its constituent structures (hippocampus, amygdala, parahippocampal gyrus). Despite evidence for frontal lobe functional abnormalities, structural MRI investigations less consistently found abnormalities, with 55% describing volume reduction. It may be that frontal lobe volume changes are small, and near the threshold for MRI detection. The parietal and occipital lobes were much less studied; about half of the studies showed positive findings. Most studies of cortical gray matter (86%) found volume reductions were not diffuse, but more pronounced in certain areas. About two thirds of the studies of subcortical structures of thalamus, corpus callosum and basal ganglia (which tend to increase volume with typical neuroleptics), show positive findings, as do almost all (91%) studies of cavum septi pellucidi (CSP). Most data were consistent with a developmental model, but growing evidence was compatible also with progressive, neurodegenerative features, suggesting a "two-hit" model of schizophrenia, for which a cellular hypothesis is discussed. The relationship of clinical

  1. MRI anatomy of schizophrenia

    OpenAIRE

    McCarley, Robert William; Wible, Cynthia Gayle; Frumin, Melissa; Hirayasu, Yoshio; Levitt, James Jonathan; Fischer, Iris A.; Shenton, Martha Elizabeth

    1999-01-01

    Structural magnetic resonance imaging (MRI) data have provided much evidence in support of our current view that schizophrenia is a brain disorder with altered brain structure, and consequently involving more than a simple disturbance in neurotransmission. This review surveys 118 peer–reviewed studies with control group from 1987 to May 1998. Most studies (81%) do not find abnormalities of whole brain/intracranial contents, while lateral ventricle enlargement is reported in 77%, and third ven...

  2. MRI in insulinomas

    International Nuclear Information System (INIS)

    Liessi, Guido; Pasquali, Claudio; Alfano D'Andrea, Alfonso; Pedrazzoli, Sergio; Scandellari, Cesare

    1992-01-01

    After establishing the diagnosis of an insulinoma, most surgeons prefer preoperative localization. Selective arteriography is usually considered the gold standard for this purpose. Recently, computed tomography (CT) and preoperative US have contended the role to angiography. MRI has been used in few cases of endocrine pancreatic tumors, and its role in this particular field has to be defined. Between November 1988-September 1990 7 adult patients who had undergone surgery were evaluated. Eight tumors were resected in 6 patients who were cured; in an 18-year-old woman surgical treatment was unsuccessful. Arterio-graphy, CT, preoperative US, MRI and intraoperative US detected 2, 6, 6, 5 and 6 tumors respectively. Two insulinomas (0.2 and 0.7 cm) were found at histologic examination in resected specimen. The ability of intra-operative US and careful surgical exploration to resolve more than 90 percent of cases makes the preoperative use of arteriography and CT questionable value. If further experience confirms these findings, US and MRI may suffice. (author). 13 refs.; 3 figs.; 1 tab

  3. MRI of symptomatic shoulders

    International Nuclear Information System (INIS)

    Kikukawa, Kenshi; Segata, Tateki; Kunitake, Katsuhiko; Morisawa, Keizo; Harada, Masataka; Hirano, Mako

    2004-01-01

    The purpose of this study was to determine the prevalence of cuff tear and acromioclavicular joint (ACJ) osteoarthrosis by magnetic resonance imaging (MRI) evaluation in symptomatic shoulders. MRI was performed on 124 shoulders in 115 patients whose age ranged from 16 to 83 years (average: 58.0 years). There were 74 men (79 shoulders) and 41 women (45 shoulders). The patients were divided into three groups according to age; A group (10 shoulders: 16-29 years), B group (43 shoulders: 30-59 years), and C group (71 shoulders: 60-83 years). Rotator cuff tears and ACJ osteoarthrosis were graded on scales 0 to 3 (normal, increased signal intensity, incomplete, complete), and 1 to 4 (none, mild, moderate, severe), respectively. There was a significant difference in the severity of the cuff tears and the ACJ osteoarthrosis with respect to age. Twenty percent of the shoulders were graded incomplete or complete cuff tears in group A, 88% in group B, and 93% in group C. No shoulders were graded moderate or severe ACJ changes in group A, 63% in group B, and 93% in group C. There was a definite correlation between the cuff tears and ACJ osteoarthrosis. MRI of the symptomatic shoulders indicated well correlation between the rotator cuff tears and ACJ osteoarthrosis. (author)

  4. Muscle magnetic resonance imaging sensitivity does not decrease in chronic, mild, or proximal lower limb neuropathies.

    Science.gov (United States)

    Deroide, Nicolas; Bousson, Valérie; Daguet, Edouard; Dumurgier, Julien; Tin, Sophie Ng Wing; Hannouche, Didier; Richette, Pascal; Beaudreuil, Johann; Lioté, Frédéric; Lévy, Bernard; Vicaut, Eric; Laredo, Jean Denis; Kubis, Nathalie

    2012-05-01

    Muscle magnetic resonance imaging (MRI) is an innovative tool for exploring focal neuropathies. However, its usefulness in mild, proximal, or chronic lesions, when electromyography (EMG), the current "gold standard" sensitivity is inadequate, has yet to be studied. Clinical, MRI, and EMG examinations were performed in 113 muscles of 17 consecutive patients with clinically diagnosed lower limb focal neuropathies. The sensitivity and specificity of MRI and EMG were evaluated in relation to disease duration, severity, and anatomical location. Muscle MRI was highly sensitive for the detection of denervated muscle, and, unlike EMG, its sensitivity did not decrease regardless of the anatomical location, duration, or severity of the neuropathy. Five MRI false positives were noted, including three in the thigh muscles. Muscle MRI is an alternative tool to EMG in proximal, mild, or chronic clinical diagnoses of lower limb focal neuropathies. However, it also seems prone to false-positive results, particularly in proximal muscles. Copyright © 2012 Wiley Periodicals, Inc.

  5. Exploring fMRI Data for Periodic Signal Components

    DEFF Research Database (Denmark)

    Hansen, Lars Kai; Nielsen, Finn Årup; Larsen, Jan

    2002-01-01

    We use a Bayesian framework to detect periodic components in fMRI data. The resulting detector is sensitive to periodic components with a flexible number of harmonics and with arbitrary amplitude and phases of the harmonics. It is possible to detect the correct number of harmonics in periodic sig...

  6. Functional MRI of human hypothalamic responses following glucose ingestion

    NARCIS (Netherlands)

    Smeets, P.A.M.; Graaf, C. de; Stafleu, A.; Osch, M.J.P. van; Grond, J. van der

    2005-01-01

    The hypothalamus is intimately involved in the regulation of food intake, integrating multiple neural and hormonal signals. Several hypothalamic nuclei contain glucose-sensitive neurons, which play a crucial role in energy homeostasis. Although a few functional magnetic resonance imaging (fMRI)

  7. Whole-body MRI in adult inflammatory myopathies: Do we need imaging of the trunk?

    International Nuclear Information System (INIS)

    Filli, Lukas; Manoliu, Andrei; Andreisek, Gustav; Guggenberger, Roman; Maurer, Britta

    2015-01-01

    To evaluate whether imaging of the trunk could be omitted in patients with inflammatory myopathies without losing diagnostic accuracy using a restricted whole-body magnetic resonance imaging (rWB-MRI) protocol. After approval by the institutional review board, this study was performed in 63 patients (male/female, 13/50; median age, 52 years; range, 20-81 years) with new-onset myopathic symptoms (group 1, n = 41) or previously diagnosed inflammatory myopathy (group 2, n = 22). After performing whole-body MRI (WB-MRI) at 3.0 Tesla, myositis and fatty atrophy were evaluated in different muscles by two independent radiologists. The intra-class correlation coefficient (ICC) was calculated to evaluate inter-observer reliability. Acquisition time was 56:01 minutes for WB-MRI and 37:37 minutes (32.8 % shorter) for rWB-MRI. In group 1, 14 patients were diagnosed with inflammatory myopathy based on muscle biopsy. rWB-MRI and WB-MRI showed equal sensitivity (42.9 %) and specificity (100 %) for myositis, and showed equal sensitivity (71.4 %) and similar specificity (63.0 % and 48.1 %, respectively) for fatty atrophy. No myositis was found in the body trunk in any patient. Inter-observer reliability was between substantial and perfect (ICC, 0.77-1.00). rWB-MRI showed diagnostic accuracy similar to WB-MRI for inflammatory myopathy at markedly reduced overall acquisition time. (orig.)

  8. Whole-body MRI in adult inflammatory myopathies: Do we need imaging of the trunk?

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Manoliu, Andrei; Andreisek, Gustav; Guggenberger, Roman [University Hospital Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Maurer, Britta [University Hospital Zurich, University of Zurich, Division of Rheumatology, Zurich (Switzerland)

    2015-12-15

    To evaluate whether imaging of the trunk could be omitted in patients with inflammatory myopathies without losing diagnostic accuracy using a restricted whole-body magnetic resonance imaging (rWB-MRI) protocol. After approval by the institutional review board, this study was performed in 63 patients (male/female, 13/50; median age, 52 years; range, 20-81 years) with new-onset myopathic symptoms (group 1, n = 41) or previously diagnosed inflammatory myopathy (group 2, n = 22). After performing whole-body MRI (WB-MRI) at 3.0 Tesla, myositis and fatty atrophy were evaluated in different muscles by two independent radiologists. The intra-class correlation coefficient (ICC) was calculated to evaluate inter-observer reliability. Acquisition time was 56:01 minutes for WB-MRI and 37:37 minutes (32.8 % shorter) for rWB-MRI. In group 1, 14 patients were diagnosed with inflammatory myopathy based on muscle biopsy. rWB-MRI and WB-MRI showed equal sensitivity (42.9 %) and specificity (100 %) for myositis, and showed equal sensitivity (71.4 %) and similar specificity (63.0 % and 48.1 %, respectively) for fatty atrophy. No myositis was found in the body trunk in any patient. Inter-observer reliability was between substantial and perfect (ICC, 0.77-1.00). rWB-MRI showed diagnostic accuracy similar to WB-MRI for inflammatory myopathy at markedly reduced overall acquisition time. (orig.)

  9. The Application of MRI for Depiction of Subtle Blood Brain Barrier Disruption in Stroke

    OpenAIRE

    David Israeli, David Tanne, Dianne Daniels, David Last, Ran Shneor, David Guez, Efrat Landau, Yiftach Roth, Aharon Ocherashvilli, Mati Bakon, Chen Hoffman, Amit Weinberg, Talila Volk, Yael Mardor

    2011-01-01

    The development of imaging methodologies for detecting blood-brain-barrier (BBB) disruption may help predict stroke patient's propensity to develop hemorrhagic complications following reperfusion. We have developed a delayed contrast extravasation MRI-based methodology enabling real-time depiction of subtle BBB abnormalities in humans with high sensitivity to BBB disruption and high spatial resolution. The increased sensitivity to subtle BBB disruption is obtained by acquiring T1-weighted MRI...

  10. The Application of MRI for Depiction of Subtle Blood Brain Barrier Disruption in Stroke

    OpenAIRE

    Israeli, David; Tanne, David; Daniels, Dianne; Last, David; Shneor, Ran; Guez, David; Landau, Efrat; Roth, Yiftach; Ocherashvilli, Aharon; Bakon, Mati; Hoffman, Chen; Weinberg, Amit; Volk, Talila; Mardor, Yael

    2010-01-01

    The development of imaging methodologies for detecting blood-brain-barrier (BBB) disruption may help predict stroke patient's propensity to develop hemorrhagic complications following reperfusion. We have developed a delayed contrast extravasation MRI-based methodology enabling real-time depiction of subtle BBB abnormalities in humans with high sensitivity to BBB disruption and high spatial resolution. The increased sensitivity to subtle BBB disruption is obtained by acquiring T1-weighted MRI...

  11. Accuracy of MRI findings in chronic lateral ankle ligament injury: Comparison with surgical findings

    Energy Technology Data Exchange (ETDEWEB)

    Park, H.-J. [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Department of Radiology, Kangwon National University, School of Medicine, Chuncheon (Korea, Republic of); Cha, S.-D. [Department of Orthopedic Surgery, Myongji Hospital, Kwandong University, College of Medicine, Koyang (Korea, Republic of); Kim, S.S. [Department of Radiology, Kangwon National University, School of Medicine, Chuncheon (Korea, Republic of); Rho, M.-H., E-mail: parkhiji@kangwon.ac.kr [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kwag, H.-J. [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Park, N.-H. [Department of Radiology, Myongji Hospital, Kwandong University, College of Medicine, Koyang (Korea, Republic of); Lee, S.-Y. [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2012-04-15

    Aim: To evaluate the accuracy of magnetic resonance imaging (MRI) findings in chronic lateral ankle ligament injury in comparison with that of surgical findings. Materials and methods: Forty-eight cases (25 men, 23 women, mean age 36 years) of clinically suspected chronic ankle ligament injury underwent MRI studies and surgery. Sagittal, coronal, and axial, T1-weighted, spin-echo, proton density and T2-weighted, fast spin-echo images with fat saturation were obtained in all patients. MRI examinations were read in consensus by two fellowship-trained academic musculoskeletal radiologists who evaluated the lateral ankle ligaments, including the anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) without clinical information. The results of the MRI studies were then compared with the surgical findings. Results: The MRI findings of ATFL injury showed a sensitivity of detection of complete tears of 75% and specificity of 86%. The sensitivity of detection of partial tears was 75% and the specificity was 78%. The sensitivity of detection of sprains was 44% and the specificity was 88%. Regarding the MRI findings of CFL injury, the sensitivity of detection of complete tears was 50% and the specificity was 98%. The sensitivity of detection of partial tear was 83% and the specificity was 93%. The sensitivity of detection of sprains was 100% and the specificity was 90%. Regarding the ATFL, the accuracies of detection were 88, 58, 77, and 85% for no injury, sprain, partial tear, and complete tear, respectively, and for the CFL the accuracies of detection were 90, 90, 92, and 96% for no injury, sprain, partial tear, and complete tear, respectively. Conclusions: The diagnosis of a complete tear of the ATFL on MRI is more sensitive than the diagnosis of a complete tear of the CFL. MRI findings of CFL injury are diagnostically specific but are not sensitive. However, only normal findings and complete tears were statistically significant between ATFL and CFL (p

  12. Accuracy of MRI findings in chronic lateral ankle ligament injury: Comparison with surgical findings

    International Nuclear Information System (INIS)

    Park, H.-J.; Cha, S.-D.; Kim, S.S.; Rho, M.-H.; Kwag, H.-J.; Park, N.-H.; Lee, S.-Y.

    2012-01-01

    Aim: To evaluate the accuracy of magnetic resonance imaging (MRI) findings in chronic lateral ankle ligament injury in comparison with that of surgical findings. Materials and methods: Forty-eight cases (25 men, 23 women, mean age 36 years) of clinically suspected chronic ankle ligament injury underwent MRI studies and surgery. Sagittal, coronal, and axial, T1-weighted, spin-echo, proton density and T2-weighted, fast spin-echo images with fat saturation were obtained in all patients. MRI examinations were read in consensus by two fellowship-trained academic musculoskeletal radiologists who evaluated the lateral ankle ligaments, including the anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) without clinical information. The results of the MRI studies were then compared with the surgical findings. Results: The MRI findings of ATFL injury showed a sensitivity of detection of complete tears of 75% and specificity of 86%. The sensitivity of detection of partial tears was 75% and the specificity was 78%. The sensitivity of detection of sprains was 44% and the specificity was 88%. Regarding the MRI findings of CFL injury, the sensitivity of detection of complete tears was 50% and the specificity was 98%. The sensitivity of detection of partial tear was 83% and the specificity was 93%. The sensitivity of detection of sprains was 100% and the specificity was 90%. Regarding the ATFL, the accuracies of detection were 88, 58, 77, and 85% for no injury, sprain, partial tear, and complete tear, respectively, and for the CFL the accuracies of detection were 90, 90, 92, and 96% for no injury, sprain, partial tear, and complete tear, respectively. Conclusions: The diagnosis of a complete tear of the ATFL on MRI is more sensitive than the diagnosis of a complete tear of the CFL. MRI findings of CFL injury are diagnostically specific but are not sensitive. However, only normal findings and complete tears were statistically significant between ATFL and CFL (p

  13. Sensitivity analysis

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003741.htm Sensitivity analysis To use the sharing features on this page, please enable JavaScript. Sensitivity analysis determines the effectiveness of antibiotics against microorganisms (germs) ...

  14. Rapid MRI evaluation of acute intracranial hemorrhage in pediatric head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, Maura E.; Jaju, Alok [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Ciolino, Jody D. [Northwestern University, Biostatistics Collaboration Center, Department of Preventive Medicine Feinberg School of Medicine, Chicago, IL (United States); Alden, Tord [Northwestern University Feinberg School of Medicine, Department of Neurological Surgery, Chicago, IL (United States); Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Neurosurgery, Chicago, IL (United States)

    2016-08-15

    Rapid MRI with ultrafast T2 sequences can be performed without sedation and is often used in place of computed tomography (CT) to evaluate pediatric patients for indications such as hydrocephalus. This study investigated the sensitivity of rapid magnetic resonance imaging (MRI) for detection and follow-up of acute intracranial hemorrhage in comparison to CT, which is commonly the first-line imaging. Patients presenting to a pediatric hospital with acute intracranial hemorrhage on CT and follow-up rapid MRI within 48 h were included. Rapid MRI studies consisted of three plane ultrafast T2 sequences either with or without axial gradient echo (GRE) sequences. Identification of hemorrhage on rapid MRI was assessed by readers both blinded and unblinded to prior CT results. One hundred two acute hemorrhages in 61 patients were identified by CT. Rapid MRI detection of subdural and epidural hemorrhages was modest in the absence of prior CT for comparison (sensitivity 61-74 %), but increased with review of the prior CT (sensitivity 80-86 %). Hemorrhage size was a significant predictor of detection (p < 0.0001). Three plane fast T2 images alone without GRE sequences were poor at detecting subarachnoid hemorrhage (sensitivity 10-25 %); rapid MRI with GRE sequences identified the majority of subarachnoid hemorrhage (sensitivity 71-93 %). GRE modestly increased detection of other extra-axial hemorrhages. Rapid MRI with GRE sequences is sensitive for most acute intracranial hemorrhages only when a prior CT is available for review. Rapid MRI is not adequate to replace CT in initial evaluation of intracranial hemorrhages but may be helpful in follow-up of known hemorrhages. (orig.)

  15. Rapid MRI evaluation of acute intracranial hemorrhage in pediatric head trauma

    International Nuclear Information System (INIS)

    Ryan, Maura E.; Jaju, Alok; Ciolino, Jody D.; Alden, Tord

    2016-01-01

    Rapid MRI with ultrafast T2 sequences can be performed without sedation and is often used in place of computed tomography (CT) to evaluate pediatric patients for indications such as hydrocephalus. This study investigated the sensitivity of rapid magnetic resonance imaging (MRI) for detection and follow-up of acute intracranial hemorrhage in comparison to CT, which is commonly the first-line imaging. Patients presenting to a pediatric hospital with acute intracranial hemorrhage on CT and follow-up rapid MRI within 48 h were included. Rapid MRI studies consisted of three plane ultrafast T2 sequences either with or without axial gradient echo (GRE) sequences. Identification of hemorrhage on rapid MRI was assessed by readers both blinded and unblinded to prior CT results. One hundred two acute hemorrhages in 61 patients were identified by CT. Rapid MRI detection of subdural and epidural hemorrhages was modest in the absence of prior CT for comparison (sensitivity 61-74 %), but increased with review of the prior CT (sensitivity 80-86 %). Hemorrhage size was a significant predictor of detection (p < 0.0001). Three plane fast T2 images alone without GRE sequences were poor at detecting subarachnoid hemorrhage (sensitivity 10-25 %); rapid MRI with GRE sequences identified the majority of subarachnoid hemorrhage (sensitivity 71-93 %). GRE modestly increased detection of other extra-axial hemorrhages. Rapid MRI with GRE sequences is sensitive for most acute intracranial hemorrhages only when a prior CT is available for review. Rapid MRI is not adequate to replace CT in initial evaluation of intracranial hemorrhages but may be helpful in follow-up of known hemorrhages. (orig.)

  16. The search for neuroimaging biomarkers of Alzheimer's disease with advanced MRI techniques

    Energy Technology Data Exchange (ETDEWEB)

    Li, Tie-Qiang (Karolinska Huddinge - Medical Physics, Stockholm (Sweden)), email: tieqiang.li@karolinska.se; Wahlund, Lars-Olof (Dept. of Neurobiology, Care Sciences and Society, Karolinska Institute, Stockholm (Sweden))

    2011-02-15

    The aim of this review is to examine the recent literature on using advanced magnetic resonance imaging (MRI) techniques for finding neuroimaging biomarkers that are sensitive to the detection of risks for Alzheimer's disease (AD). Since structural MRI techniques, such as brain structural volumetry and voxel based morphometry (VBM), have been widely used for AD studies and extensively reviewed, we will only briefly touch on the topics of volumetry and morphometry. The focus of the current review is about the more recent developments in the search for AD neuroimaging biomarkers with functional MRI (fMRI), resting-state functional connectivity MRI (fcMRI), diffusion tensor imaging (DTI), arterial spin-labeling (ASL), and magnetic resonance spectroscopy (MRS)

  17. The search for neuroimaging biomarkers of Alzheimer's disease with advanced MRI techniques

    International Nuclear Information System (INIS)

    Li, Tie-Qiang; Wahlund, Lars-Olof

    2011-01-01

    The aim of this review is to examine the recent literature on using advanced magnetic resonance imaging (MRI) techniques for finding neuroimaging biomarkers that are sensitive to the detection of risks for Alzheimer's disease (AD). Since structural MRI techniques, such as brain structural volumetry and voxel based morphometry (VBM), have been widely used for AD studies and extensively reviewed, we will only briefly touch on the topics of volumetry and morphometry. The focus of the current review is about the more recent developments in the search for AD neuroimaging biomarkers with functional MRI (fMRI), resting-state functional connectivity MRI (fcMRI), diffusion tensor imaging (DTI), arterial spin-labeling (ASL), and magnetic resonance spectroscopy (MRS)

  18. MRI diagnosis of meningovascular neurosyphilis

    International Nuclear Information System (INIS)

    Chen Shuang; Qian Jianguo; Feng Xiaoyuan

    2005-01-01

    Objective: To evaluate the value and limitation of MRI in the diagnosis of meningovascular neurosyphilis. Methods: Five cases of neurosyphilis confirmed by clinical history/laboratory were examined with MRI (3 plain MRI, 2 enhanced MRI). The results of blood and CSF TPPA/RPR were positive and HIV was negative. Results: Abnormal signals were demonstrated in the temporal lobe in 3 cases, and infarction was revealed in the basal ganglion and periventricular white matter in another 2 cases. There was no marked contrast enhancement in the 2 cases. Conclusion: Meningovascular neurosyphilis has no characteristic features on MRI, but MRI is an effective method in delineating the size, range, and characters of neurosyphilis, and it is also an useful modality to follow-up after antibiotic therapy. (authors)

  19. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    Science.gov (United States)

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  20. Functional MRI of the kidneys

    OpenAIRE

    Zhang, Jeff L.; Rusinek, Henry; Chandarana, Hersh; Lee, Vivian S.

    2013-01-01

    Renal function is characterized by different physiologic aspects, including perfusion, glomerular filtration, interstitial diffusion and tissue oxygenation. MRI shows great promise in assessing these renal tissue characteristics noninvasively. The last decade has witnessed a dramatic progress in MRI techniques for renal function assessment. This article briefly describes relevant renal anatomy and physiology, reviews the applications of functional MRI techniques for the diagnosis of renal dis...

  1. Prediction of mechanical properties of trabecular bone using quantitative MRI

    International Nuclear Information System (INIS)

    Lammentausta, E; Hakulinen, M A; Jurvelin, J S; Nieminen, M T

    2006-01-01

    Techniques for quantitative magnetic resonance imaging (MRI) have been developed for non-invasive estimation of the mineral density and structure of trabecular bone. The R* 2 relaxation rate (i.e. 1/T* 2 ) is sensitive to bone mineral density (BMD) via susceptibility differences between trabeculae and bone marrow, and by binarizing MRI images, structural variables, such as apparent bone volume fraction, can be assessed. In the present study, trabecular bone samples of human patellae were investigated in vitro at 1.5 T to determine the ability of MRI-derived variables (R* 2 and bone volume fraction) to predict the mechanical properties (Young's modulus, yield stress and ultimate strength). Further, the MRI variables were correlated with reference measurements of volumetric BMD and bone area fraction as determined with a clinical pQCT system. The MRI variables correlated significantly (p 2 and MRI-derived bone volume fraction further improved the prediction of yield stress and ultimate strength. Although pQCT showed a trend towards better prediction of the mechanical properties, current results demonstrate the feasibility of combined MR imaging of marrow susceptibility and bone volume fraction in predicting the mechanical strength of trabecular bone and bone mineral density

  2. Comparison of standard, prone and cine MRI in the evaluation of tethered cord

    International Nuclear Information System (INIS)

    Singh, Sukhjinder; Kline-Fath, Beth; Racadio, Judy M.; Bierbrauer, Karin; Salisbury, Shelia; Macaluso, Maurizio; Jackson, Elizabeth C.; Egelhoff, John C.

    2012-01-01

    Tethered cord syndrome (TCS) is defined by abnormal traction on the spinal cord that confines its movement. Surgical cord release usually stops neurological deterioration; therefore, early and accurate neuroradiological diagnosis is important. Supine MRI is the imaging modality of choice, but prone MRI and cine MRI can demonstrate cord movement. We compared the diagnostic accuracies of standard MRI, prone MRI and cine MRI in patients with clinical suspicion of TCS and evaluated inter-reader reliability for MR imaging. Children who underwent MRI for suspicion of TCS were retrospectively identified. Supine, prone and cine MRI studies were re-read by two pediatric neuroradiologists. Conus level, filum appearance and cord movement were documented. Thirteen of 49 children had tethered cord documented at surgery. Conus level had the highest diagnostic accuracy (sensitivity 69-77%, specificity 94%, positive predictive value 82-83%, negative predictive value 89-92%, correct diagnosis 88-90%) and highest between-reader concordance (98%). Prone and cine MRI did not add to the accuracy of the supine imaging. Conus level provides the highest diagnostic accuracy and inter-reader reliability in TCS. Until a larger series is evaluated, it remains questionable whether prone or cine MRI provides enough additional diagnostic information to warrant routine use. (orig.)

  3. Comparison of standard, prone and cine MRI in the evaluation of tethered cord

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Sukhjinder [Cohen Children' s Medical Center, Department of Radiology, New Hyde Park, NY (United States); Kline-Fath, Beth; Racadio, Judy M. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Bierbrauer, Karin [Cincinnati Children' s Hospital Medical Center, Department of Neurosurgery, Cincinnati, OH (United States); Salisbury, Shelia; Macaluso, Maurizio [Cincinnati Children' s Hospital Medical Center, Division of Biostatistics and Epidemiology, Cincinnati, OH (United States); Jackson, Elizabeth C. [Cincinnati Children' s Hospital Medical Center, Department of Pediatrics, Division of Nephrology, Cincinnati, OH (United States); Egelhoff, John C. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Phoenix Children' s Hospital, Department of Radiology, Phoenix, AZ (United States)

    2012-06-15

    Tethered cord syndrome (TCS) is defined by abnormal traction on the spinal cord that confines its movement. Surgical cord release usually stops neurological deterioration; therefore, early and accurate neuroradiological diagnosis is important. Supine MRI is the imaging modality of choice, but prone MRI and cine MRI can demonstrate cord movement. We compared the diagnostic accuracies of standard MRI, prone MRI and cine MRI in patients with clinical suspicion of TCS and evaluated inter-reader reliability for MR imaging. Children who underwent MRI for suspicion of TCS were retrospectively identified. Supine, prone and cine MRI studies were re-read by two pediatric neuroradiologists. Conus level, filum appearance and cord movement were documented. Thirteen of 49 children had tethered cord documented at surgery. Conus level had the highest diagnostic accuracy (sensitivity 69-77%, specificity 94%, positive predictive value 82-83%, negative predictive value 89-92%, correct diagnosis 88-90%) and highest between-reader concordance (98%). Prone and cine MRI did not add to the accuracy of the supine imaging. Conus level provides the highest diagnostic accuracy and inter-reader reliability in TCS. Until a larger series is evaluated, it remains questionable whether prone or cine MRI provides enough additional diagnostic information to warrant routine use. (orig.)

  4. MRI-based decision tree model for diagnosis of biliary atresia.

    Science.gov (United States)

    Kim, Yong Hee; Kim, Myung-Joon; Shin, Hyun Joo; Yoon, Haesung; Han, Seok Joo; Koh, Hong; Roh, Yun Ho; Lee, Mi-Jung

    2018-02-23

    To evaluate MRI findings and to generate a decision tree model for diagnosis of biliary atresia (BA) in infants with jaundice. We retrospectively reviewed features of MRI and ultrasonography (US) performed in infants with jaundice between January 2009 and June 2016 under approval of the institutional review board, including the maximum diameter of periportal signal change on MRI (MR triangular cord thickness, MR-TCT) or US (US-TCT), visibility of common bile duct (CBD) and abnormality of gallbladder (GB). Hepatic subcapsular flow was reviewed on Doppler US. We performed conditional inference tree analysis using MRI findings to generate a decision tree model. A total of 208 infants were included, 112 in the BA group and 96 in the non-BA group. Mean age at the time of MRI was 58.7 ± 36.6 days. Visibility of CBD, abnormality of GB and MR-TCT were good discriminators for the diagnosis of BA and the MRI-based decision tree using these findings with MR-TCT cut-off 5.1 mm showed 97.3 % sensitivity, 94.8 % specificity and 96.2 % accuracy. MRI-based decision tree model reliably differentiates BA in infants with jaundice. MRI can be an objective imaging modality for the diagnosis of BA. • MRI-based decision tree model reliably differentiates biliary atresia in neonatal cholestasis. • Common bile duct, gallbladder and periportal signal changes are the discriminators. • MRI has comparable performance to ultrasonography for diagnosis of biliary atresia.

  5. 3He-MRI in follow-up of lung transplant recipients

    International Nuclear Information System (INIS)

    Gast, Klaus Kurt; Zaporozhan, Julia; Ley, Sebastian; Biedermann, Alexander; Knitz, Frank; Eberle, Balthasar; Schmiedeskamp, Joerg; Heussel, Claus-Peter; Mayer, Eckhard; Schreiber, Wolfgang Guenter; Thelen, Manfred; Kauczor, Hans-Ulrich

    2004-01-01

    The aim of this study was to evaluate the possible contribution of 3 He-MRI to detect obliterative bronchiolitis (OB) in the follow-up of lung transplant recipients. Nine single- and double-lung transplanted patients were studied by an initial and a follow-up 3 He-MRI study. Images were evaluated subjectively by estimation of ventilation defect area and quantitatively by individually adapted threshold segmentation and subsequent calculation of ventilated lung volume. Bronchiolitis obliterans syndrome (BOS) was diagnosed using pulmonary function tests. At 3 He-MRI, OB was suspected if ventilated lung volume had decreased by 10% or more at the follow-up MRI study compared with the initial study. General accordance between pulmonary function testing and 3 He-MRI was good, although subjective evaluation of 3 He-MRI underestimated improvement in ventilation as obtained by pulmonary function tests. The 3 He-MRI indicated OB in 6 cases. According to pulmonary function tests, BOS was diagnosed in 5 cases. All diagnoses of BOS were also detected by 3 He-MRI. In 2 of these 5 cases, 3 He-MRI indicated OB earlier than pulmonary function tests. The results support the hypothesis that 3 He-MRI may be sensitive for early detection of OB and emphasize the need for larger prospective follow-up studies. (orig.)

  6. Bilateral symmetry analysis of breast MRI

    International Nuclear Information System (INIS)

    Alterson, Robert; Plewes, Donald B

    2003-01-01

    Mammographic interpretation often uses symmetry between left and right breasts to indicate the site of potential tumour masses. This approach has not been applied to breast images obtained from MRI. We present an automatic technique for breast symmetry detection based on feature extraction techniques which does not require any efforts to co-register breast MRI data. The approach applies computer-vision techniques to detect natural biological symmetries in breast MR scans based on three objective measures of similarity: multiresolution non-orthogonal wavelet representation, three-dimensional intensity distributions and co-occurrence matrices. Statistical distributions that are invariant to feature localization are computed for each of the extracted image features. These distributions are later compared against each other to account for perceptual similarity. Studies based on 51 normal MRI scans of randomly selected patients showed that the sensitivity of symmetry detection rate approached 94%. The symmetry analysis procedure presented in this paper can be applied as an aid in detecting breast tissue changes arising from disease

  7. Clinical and MRI findings of brucellar spondylodiscitis

    International Nuclear Information System (INIS)

    Bozgeyik, Zulkif; Ozdemir, Huseyin; Demirdag, Kutbettin; Ozden, Mehmet; Sonmezgoz, Fitnet; Ozgocmen, Salih

    2008-01-01

    Objective: The aim of this retrospective study was to report the clinical features and MR imaging findings of patients with brucellar spondylodiscitis. Materials and methods: Twenty-two patients with spondylodiscitis, recruited among 152 patients with brucellosis referred from the Department of Infectious Diseases. Patients were diagnosed based on positive clinical findings, ≥1/160 titers of brucella agglutination tests and/or positive blood cultures. Magnetic resonance imaging (MRI) was performed to all of the patients with spondylodiscitis. Signal changes and enhancement of vertebral bodies, involvement of paravertebral soft tissues and epidural spaces, nerve root and cord compression and abscess formation were assessed. Results: All of the patients (n = 22; 7 F, 15 M) had ≥1/160 titers of brucella agglutination test and blood culture was positive in 9. A great majority of the patients had involvement at only one vertebrae level (n = 21, 95.5%), whereas one patient (4.5%) had multilevel involvement. In MRI, eight patients had soft tissue involvement and three had abscess formation. All cases had vertebral and discal enhancement. Additionally epidural extension was detected in four cases, posterior longitudinal ligament (PLL) elevation in five cases and root compression in two cases. Conclusion: Brucella is still a public health problem in endemic areas. MRI is a highly sensitive and non-invasive imaging technique which should be first choice of imaging in the early diagnosis of spondylodiscitis

  8. Clinical and MRI findings of brucellar spondylodiscitis

    Energy Technology Data Exchange (ETDEWEB)

    Bozgeyik, Zulkif [Department of Radiology, Faculty of Medicine, Firat University, 23119 Elazig (Turkey)], E-mail: bozgeyik4@hotmail.com; Ozdemir, Huseyin [Department of Radiology, Faculty of Medicine, Firat University, 23119 Elazig (Turkey); Demirdag, Kutbettin; Ozden, Mehmet [Department of Infection Disease, Faculty of Medicine, Firat University, Elazig (Turkey); Sonmezgoz, Fitnet [Department of Radiology, Faculty of Medicine, Firat University, 23119 Elazig (Turkey); Ozgocmen, Salih [Division of Rheumatology, Department of PMR, Faculty of Medicine, Firat University, Elazig (Turkey)

    2008-07-15

    Objective: The aim of this retrospective study was to report the clinical features and MR imaging findings of patients with brucellar spondylodiscitis. Materials and methods: Twenty-two patients with spondylodiscitis, recruited among 152 patients with brucellosis referred from the Department of Infectious Diseases. Patients were diagnosed based on positive clinical findings, {>=}1/160 titers of brucella agglutination tests and/or positive blood cultures. Magnetic resonance imaging (MRI) was performed to all of the patients with spondylodiscitis. Signal changes and enhancement of vertebral bodies, involvement of paravertebral soft tissues and epidural spaces, nerve root and cord compression and abscess formation were assessed. Results: All of the patients (n = 22; 7 F, 15 M) had {>=}1/160 titers of brucella agglutination test and blood culture was positive in 9. A great majority of the patients had involvement at only one vertebrae level (n = 21, 95.5%), whereas one patient (4.5%) had multilevel involvement. In MRI, eight patients had soft tissue involvement and three had abscess formation. All cases had vertebral and discal enhancement. Additionally epidural extension was detected in four cases, posterior longitudinal ligament (PLL) elevation in five cases and root compression in two cases. Conclusion: Brucella is still a public health problem in endemic areas. MRI is a highly sensitive and non-invasive imaging technique which should be first choice of imaging in the early diagnosis of spondylodiscitis.

  9. Muscle MRI findings in facioscapulohumeral muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Gerevini, Simonetta; Caliendo, Giandomenico; Falini, Andrea [IRCCS San Raffaele Scientific Institute, Neuroradiology Unit, Head and Neck Department, Milan (Italy); Scarlato, Marina; Previtali, Stefano Carlo [IRCCS San Raffaele Scientific Institute, Department of Neurology, INSPE and Division of Neuroscience, Milan (Italy); Maggi, Lorenzo; Pasanisi, Barbara; Morandi, Lucia [Fondazione IRCCS Istituto Neurologico ' ' Carlo Besta' ' , Neuromuscular Diseases and Neuroimmunology Unit, Milan (Italy); Cava, Mariangela [IRCCS San Raffaele Scientific Institute, Department of Radiology and Center for Experimental Imaging, Milan (Italy)

    2016-03-15

    Facioscapulohumeral muscular dystrophy (FSHD) is characterized by extremely variable degrees of facial, scapular and lower limb muscle involvement. Clinical and genetic determination can be difficult, as molecular analysis is not always definitive, and other similar muscle disorders may have overlapping clinical manifestations. Whole-body muscle MRI examination for fat infiltration, atrophy and oedema was performed to identify specific patterns of muscle involvement in FSHD patients (30 subjects), and compared to a group of control patients (23) affected by other myopathies (NFSHD). In FSHD patients, we detected a specific pattern of muscle fatty replacement and atrophy, particularly in upper girdle muscles. The most frequently affected muscles, including paucisymptomatic and severely affected FSHD patients, were trapezius, teres major and serratus anterior. Moreover, asymmetric muscle involvement was significantly higher in FSHD as compared to NFSHD patients. In conclusion, muscle MRI is very sensitive for identifying a specific pattern of involvement in FSHD patients and in detecting selective muscle involvement of non-clinically testable muscles. Muscle MRI constitutes a reliable tool for differentiating FSHD from other muscular dystrophies to direct diagnostic molecular analysis, as well as to investigate FSHD natural history and follow-up of the disease. (orig.)

  10. Optimal assessment of paediatric IBD with MRI and barium follow-through.

    Science.gov (United States)

    Giles, Edward; Hanci, Ozan; McLean, Alison; Power, Niall; Cole, Angela; Croft, Nicholas M; McDonald, Kirsteen; Chippington, Sam; Naik, Sandhia

    2012-06-01

    The present UK criterion standard for assessing children with suspected inflammatory bowel disease (IBD) is upper endoscopy, ileocolonoscopy, and barium follow-through (BaFT). Significant doses of radiation, unpalatable contrast, and volume intolerance are involved with BaFT. Practice in investigating Crohn disease (CD) is changing with the increasing use of magnetic resonance imaging (MRI). The aim of the present study was to compare BaFT and a new abdominal MRI protocol in a paediatric IBD population. All consecutive patients with a new diagnosis of IBD or requiring reassessment from September 2008 to December 2010 were investigated with both abdominal MRI and BaFT in accordance with a specific local paediatric IBD protocol. The studies were reported by nonblinded radiologists with an interest in gastrointestinal imaging. The reports were compared in conjunction with case note review. Eighty-seven patients underwent both BaFT and MRI abdomen. Thirty-one percent of patients had additional pathology on MRI, not seen on the BaFT. Sixty-seven percent of patients (n=59) had an MRI finding equivalent to BaFT. Using histology as a criterion standard for detecting terminal ileal disease, BaFT had a sensitivity and specificity of 76% and 67%, and MRI had a sensitivity and specificity of 83% and 95%, respectively. This is the largest series of small bowel MRI in a paediatric population. MRI reports were at least equivalent to BaFT. MRI had higher sensitivity and, particularly, specificity in detecting terminal ileal pathology. These findings suggest that MRI should become the criterion standard investigation in children with IBD in centres with appropriate expertise, with zero radiation exposure being highly advantageous.

  11. Cost-effectiveness of EOB-MRI for Hepatocellular Carcinoma in Japan.

    Science.gov (United States)

    Nishie, Akihiro; Goshima, Satoshi; Haradome, Hiroki; Hatano, Etsuro; Imai, Yasuharu; Kudo, Masatoshi; Matsuda, Masanori; Motosugi, Utaroh; Saitoh, Satoshi; Yoshimitsu, Kengo; Crawford, Bruce; Kruger, Eliza; Ball, Graeme; Honda, Hiroshi

    2017-04-01

    The objective of the study was to evaluate the cost-effectiveness of gadoxetic acid-enhanced magnetic resonance imaging (EOB-MRI) in the diagnosis and treatment of hepatocellular carcinoma (HCC) in Japan compared with extracellular contrast media-enhanced MRI (ECCM-MRI) and contrast media-enhanced computed tomography (CE-CT) scanning. A 6-stage Markov model was developed to estimate lifetime direct costs and clinical outcomes associated with EOB-MRI. Diagnostic sensitivity and specificity, along with clinical data on HCC survival, recurrence, treatment patterns, costs, and health state utility values, were derived from predominantly Japanese publications. Parameters unavailable from publications were estimated in a Delphi panel of Japanese clinical experts who also confirmed the structure and overall approach of the model. Sensitivity analyses, including one-way, probabilistic, and scenario analyses, were conducted to account for uncertainty in the results. Over a lifetime horizon, EOB-MRI was associated with lower direct costs (¥2,174,869) and generated a greater number of quality-adjusted life years (QALYs) (9.502) than either ECCM-MRI (¥2,365,421, 9.303 QALYs) or CE-CT (¥2,482,608, 9.215 QALYs). EOB-MRI was superior to the other diagnostic strategies considered, and this finding was robust over sensitivity and scenario analyses. A majority of the direct costs associated with HCC in Japan were found to be costs of treatment. The model results revealed the superior cost-effectiveness of the EOB-MRI diagnostic strategy compared with ECCM-MRI and CE-CT. EOB-MRI could be the first-choice imaging modality for medical care of HCC among patients with hepatitis or liver cirrhosis in Japan. Widespread implementation of EOB-MRI could reduce health care expenditures, particularly downstream treatment costs, associated with HCC. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.

  12. MRI and ultrasound in children with juvenile chronic arthritis

    International Nuclear Information System (INIS)

    Lamer, S.; Sebag, G.H.

    2000-01-01

    In this era of advancing imaging technology, a knowledge of the relative values of available imaging techniques is necessary to optimize the management of children with juvenile chronic arthritis (JCA). After clinical examination, plain films remain the initial investigation. The need for radiation protection must be a priority in children with JCA. Conventional radiographs allow grouping of the various arthritides (on the base of the distribution and pattern of joint space changes) and staging of disease progression. Ultrasound (US) is very sensitive in the detection of joint effusions, especially in the hip, and guides fluid aspiration. US and Doppler can be used for the evaluation of synovial hypertrophy and activity. Arthrography and to a certain extent nuclear studies have been replaced by magnetic resonance imaging (MRI). MRI can demonstrate articular cartilage, joint effusion, synovial hypertrophy, cortical and medullary bone, cartilage and bone perfusion, and fibrocartilaginous structures (menisci and ligaments). Contrast enhanced MRI is the most sensitive modality to determine whether an arthritic condition is present. However, it does not assist in establishing a specific diagnosis. MRI determines accurately the activity and the extent of the disease and is particularly useful in the early detection of articular damage. Finally, MRI is of major importance in the evaluation of response to local therapy (especially steroids) and the detection of complications

  13. Multi-flux-transformer MRI detection with an atomic magnetometer.

    Science.gov (United States)

    Savukov, Igor; Karaulanov, Todor

    2014-12-01

    Recently, anatomical ultra-low field (ULF) MRI has been demonstrated with an atomic magnetometer (AM). A flux-transformer (FT) has been used for decoupling MRI fields and gradients to avoid their negative effects on AM performance. The field of view (FOV) was limited because of the need to compromise between the size of the FT input coil and MRI sensitivity per voxel. Multi-channel acquisition is a well-known solution to increase FOV without significantly reducing sensitivity. In this paper, we demonstrate twofold FOV increase with the use of three FT input coils. We also show that it is possible to use a single atomic magnetometer and single acquisition channel to acquire three independent MRI signals by applying a frequency-encoding gradient along the direction of the detection array span. The approach can be generalized to more channels and can be critical for imaging applications of non-cryogenic ULF MRI where FOV needs to be large, including head, hand, spine, and whole-body imaging. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. New nontoxic double information magnetic and fluorescent MRI agent

    International Nuclear Information System (INIS)

    Kublickas, Augustinas; Rastenien, Loreta; Bloznelytė-Plėšnienė, Laima; Karalius, Nerijus; Franckevinius, Marius; Loudos, George; Fahmi, Amir; Vaisnoras, Rimas

    2015-01-01

    Today sensitivity of the MRI is not enough compared to the nuclear methods, such as positron emission tomography and single photon emission computed tomography. Challenging its extension to the nanometre scale could provide a powerful new tool for the nanosciences and nanomedicine. To achieve this potential, innovative new detection strategies are required to overcome the severe sensitivity limitations of conventional inductive detection techniques. In this regard, we perform embodiment of nanodiamonds in dendrimer matrix as additional fluorescent optical and magnetic (together with Gd (III)) imaging modalities of the MRI. New hybrid system composed of dendrimer-gadolinium Gd (III) - nanodiamond as a new contrast agent for MRI was studied. Poly(propilene-imine) PPI and poly(amidoamine) PAMAM dendrimers with fixed size of nanocavities will be used as host material to protect organism against the toxicity and also to increase relaxivity of contrast agent (resulting in the increases MRI resolution). Nanodiamond as biocompatible platform to functionalize the contrast agent will be used. This bimodal hybrid system enables to use smaller amount of the contrast agent and could permit the decrease of the lateral toxicity. This bimodal hybrid system as MRI agent is providing double information (magnetic and fluorescent) about the damaged cell.

  15. New nontoxic double information magnetic and fluorescent MRI agent

    Energy Technology Data Exchange (ETDEWEB)

    Kublickas, Augustinas; Rastenien, Loreta; Bloznelytė-Plėšnienė, Laima; Karalius, Nerijus [Liquid Crystals Laboratory, Institute of Science and Technology, Lithuanian University of Educational Sciences (Lithuania); Franckevinius, Marius [Institute of Physics, Center for Physical Sciences and Technology (Lithuania); Loudos, George [Technological Educational Institute of Athens (Greece); Fahmi, Amir [Materials Science, Rhein-Waal University of Applied Sciences (Germany); Vaisnoras, Rimas [Liquid Crystals Laboratory, Institute of Science and Technology, Lithuanian University of Educational Sciences (Lithuania)

    2015-05-18

    Today sensitivity of the MRI is not enough compared to the nuclear methods, such as positron emission tomography and single photon emission computed tomography. Challenging its extension to the nanometre scale could provide a powerful new tool for the nanosciences and nanomedicine. To achieve this potential, innovative new detection strategies are required to overcome the severe sensitivity limitations of conventional inductive detection techniques. In this regard, we perform embodiment of nanodiamonds in dendrimer matrix as additional fluorescent optical and magnetic (together with Gd (III)) imaging modalities of the MRI. New hybrid system composed of dendrimer-gadolinium Gd (III) - nanodiamond as a new contrast agent for MRI was studied. Poly(propilene-imine) PPI and poly(amidoamine) PAMAM dendrimers with fixed size of nanocavities will be used as host material to protect organism against the toxicity and also to increase relaxivity of contrast agent (resulting in the increases MRI resolution). Nanodiamond as biocompatible platform to functionalize the contrast agent will be used. This bimodal hybrid system enables to use smaller amount of the contrast agent and could permit the decrease of the lateral toxicity. This bimodal hybrid system as MRI agent is providing double information (magnetic and fluorescent) about the damaged cell.

  16. MRI assessment program. Consensus statement on clinical efficacy of MRI

    International Nuclear Information System (INIS)

    1998-05-01

    This consensus statement is largely based on the experience gained at the MRI units at the four hospitals which have operated scanners in the MRI program. It reflects the considered opinion of the radiologists responsible for the MRI services at those hospitals. Account has also been taken of relevant overseas data. This collection of opinion relates particularly to comparison with other imaging modalities. The specific comments will require further consideration as technical developments with MRI become available, additional experience is gained with gadolinium contrast material and additional data are obtained on the influence of MRI on patient management. MRI, at present, is used either to improve diagnostic accuracy when other tests are negative or equivocal, when there is strong clinical suspicion of disease, or to improve surgical or other management planning when the diagnosis known. In some situations (eg syringomyelia, congenital spinal disease, posterior fossa/cerebello-pontine angle tumours) it may entirely replace other tests (eg myelography, air contrast, CT) which are substantially less accurate and/or more invasive. In other situations (eg hemispheric brain tumours, lumbar disc protrusions) when other tests, such as CT, can be as accurate, MRI is not usually or initially indicated because it is currently more expensive and of limited availability. However, balanced against this is the fact that it does not expose the patient to potentially harmful ionising radiation. It is also stressed that MRI images depend on complex, widely variable and, as yet, incompletely understood parameters. There is concern that this may result in false positive diagnoses, especially where MRI is used alone as a screening test, or used as the initial test. For several reasons (availability, cost, medical and diagnostic efficacy), the specific comments on indications for MRI presented are based upon the assumption that MRI is a tertiary and complementary imaging examination

  17. MRI of the fetal abdomen

    International Nuclear Information System (INIS)

    Hoermann, M.; Brugger, P.C.; Witzani, L.; Prayer, D.

    2006-01-01

    Magnetic resonance imaging (MRI) is an important diagnostic component for central nervous system and thoracic diseases during fetal development. Although ultrasound remains the method of choice for observing the fetus during pregnancy, fetal MRI is being increasingly used as an additional technique for the accurate diagnosis of abdominal diseases. Recent publications confirm the value of MRI in the diagnosis of fetal gastrointestinal tract and urogenital system diseases. The following report provides an overview of MRI-examination techniques for the most frequent diseases of the abdomen. (orig.) [de

  18. Cost-effectiveness analysis of a non-contrast screening MRI protocol for vestibular schwannoma in patients with asymmetric sensorineural hearing loss

    International Nuclear Information System (INIS)

    Crowson, Matthew G.; Rocke, Daniel J.; Kaylie, David M.; Hoang, Jenny K.; Weissman, Jane L.

    2017-01-01

    We aimed to determine if a non-contrast screening MRI is cost-effective compared to a full MRI protocol with contrast for the evaluation of vestibular schwannomas. A decision tree was constructed to evaluate full MRI and screening MRI strategies for patients with asymmetric sensorineural hearing loss. If a patient were to have a positive screening MRI, s/he received a full MRI. Vestibular schwannoma prevalence, MRI specificity and sensitivity, and gadolinium anaphylaxis incidence were obtained through literature review. Institutional charge data were obtained using representative patient cohorts. One-way and probabilistic sensitivity analyses were completed to determine CE model threshold points for MRI performance characteristics and charges. The mean charge for a full MRI with contrast was significantly higher than a screening MRI ($4089 ± 1086 versus $2872 ± 741; p < 0.05). The screening MRI protocol was more cost-effective than a full MRI protocol with a willingness-to-pay from $0 to 20,000 USD. Sensitivity analyses determined that the screening protocol dominated when the screening MRI charge was less than $4678, and the imaging specificity exceeded 78.2%. The screening MRI protocol also dominated when vestibular schwannoma prevalence was varied between 0 and 1000 in 10,000 people. A screening MRI protocol is more cost-effective than a full MRI with contrast in the diagnostic evaluation of a vestibular schwannoma. A screening MRI likely also confers benefits of shorter exam time and no contrast use. Further investigation is needed to confirm the relative performance of screening protocols for vestibular schwannomas. (orig.)

  19. Cost-effectiveness analysis of a non-contrast screening MRI protocol for vestibular schwannoma in patients with asymmetric sensorineural hearing loss

    Energy Technology Data Exchange (ETDEWEB)

    Crowson, Matthew G.; Rocke, Daniel J.; Kaylie, David M. [Duke University Medical Center, Division of Otolaryngology-Head and Neck Surgery, Durham, NC (United States); Hoang, Jenny K. [Duke University Medical Center, Department of Radiology, Durham, NC (United States); Weissman, Jane L. [Oregon Health Sciences University, Professor Emerita of Diagnostic Radiology, Portland, OR (United States)

    2017-08-15

    We aimed to determine if a non-contrast screening MRI is cost-effective compared to a full MRI protocol with contrast for the evaluation of vestibular schwannomas. A decision tree was constructed to evaluate full MRI and screening MRI strategies for patients with asymmetric sensorineural hearing loss. If a patient were to have a positive screening MRI, s/he received a full MRI. Vestibular schwannoma prevalence, MRI specificity and sensitivity, and gadolinium anaphylaxis incidence were obtained through literature review. Institutional charge data were obtained using representative patient cohorts. One-way and probabilistic sensitivity analyses were completed to determine CE model threshold points for MRI performance characteristics and charges. The mean charge for a full MRI with contrast was significantly higher than a screening MRI ($4089 ± 1086 versus $2872 ± 741; p < 0.05). The screening MRI protocol was more cost-effective than a full MRI protocol with a willingness-to-pay from $0 to 20,000 USD. Sensitivity analyses determined that the screening protocol dominated when the screening MRI charge was less than $4678, and the imaging specificity exceeded 78.2%. The screening MRI protocol also dominated when vestibular schwannoma prevalence was varied between 0 and 1000 in 10,000 people. A screening MRI protocol is more cost-effective than a full MRI with contrast in the diagnostic evaluation of a vestibular schwannoma. A screening MRI likely also confers benefits of shorter exam time and no contrast use. Further investigation is needed to confirm the relative performance of screening protocols for vestibular schwannomas. (orig.)

  20. Stress cine MRI for detection of coronary artery disease

    International Nuclear Information System (INIS)

    Sommer, T.; Hofer, U.; Schild, H.

    2002-01-01

    Stress testing is the cornerstone in the diagnosis of patients with suspected coronary artery disease (CAD). Stress echocardiography has become a well-established modality for the detection of ischemia-induced wall motion abnormalities. However, display and reliable interpretation of stress echocardiography studies are user-dependent, the test reproducibility is low, and 10 to 15% of patients yield suboptimal or non-diagnostic images. Due to its high spatial and contrast resolution, MRI is known to permit an accurate determination of left ventricular function and wall thickness at rest. Early stress MRI studies provided promising results with respect to the detection of CAD. However, the clinical impact was limited due to long imaging time and problematic patient monitoring in the MRI environment. Recent technical improvements - namely ultrafast MR image acquisition - led to a significant reduction of imaging time and improved patient safety. Stress can be induced by physical exercise or pharmacologically by administration of a beta 1 -agonist (dobutamine) or vasodilatator (dipyridamole and adenosine). The best developed and most promising stress MRI technique is a high-dose dobutamine/atropine stress protocol (10, 20, 30, 40 μg/kg/min; optionally 0.25-mg fractions of atropine up to maximal dose 1 mg). Severe complications (myocardial infarction, ventricular fibrillation and sustained tachycardia, cardiogenic shock) may be expected in 0.25% of patients. Currently, data of three high-dose dobutamine stress MRI studies are available, revealing a good sensitivity (83 - 87%) and specificity (83 - 86%) in the assessment of CAD. The direct comparison between echocardiography and MRI for the detection of stress-induced wall motion abnormalities yielded better results for dobutamine-MRI in terms of sensitivity (86.2% vs. 74.3%; p [de

  1. MRI for clinically suspected pediatric appendicitis: an implemented program

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Michael M.; Gustas, Cristy N.; Choudhary, Arabinda K.; Methratta, Sosamma T.; Hulse, Michael A.; Eggli, Kathleen D.; Boal, Danielle K.B. [Penn State Milton S. Hershey Medical Center, Department of Radiology, Mail Code H066, 500 University Drive, P.O. Box 850, Hershey, PA (United States); Geeting, Glenn [Penn State Milton S. Hershey Medical Center, Department of Emergency Medicine, Hershey, PA (United States)

    2012-09-15

    Emergent MRI is now a viable alternative to CT for evaluating appendicitis while avoiding the detrimental effects of ionizing radiation. However, primary employment of MRI in the setting of clinically suspected pediatric appendicitis has remained significantly underutilized. To describe our institution's development and the results of a fully implemented clinical program using MRI as the primary imaging evaluation for children with suspected appendicitis. A four-sequence MRI protocol consisting of coronal and axial single-shot turbo spin-echo (SS-TSE) T2, coronal spectral adiabatic inversion recovery (SPAIR), and axial SS-TSE T2 with fat saturation was performed on 208 children, ages 3 to 17 years, with clinically suspected appendicitis. No intravenous or oral contrast material was administered. No sedation was administered. Data collection includes two separate areas: time parameter analysis and MRI diagnostic results. Diagnostic accuracy of MRI for pediatric appendicitis indicated a sensitivity of 97.6% (CI: 87.1-99.9%), specificity 97.0% (CI: 93.2-99.0%), positive predictive value 88.9% (CI: 76.0-96.3%), and negative predictive value 99.4% (CI: 96.6-99.9%). Time parameter analysis indicated clinical feasibility, with time requested to first sequence obtained mean of 78.7 +/- 52.5 min, median 65 min; first-to-last sequence time stamp mean 14.2 +/- 8.8 min, median 12 min; last sequence to report mean 57.4 +/- 35.2 min, median 46 min. Mean age was 11.2 +/- 3.6 years old. Girls represented 57% of patients. MRI is an effective and efficient method of imaging children with clinically suspected appendicitis. Using an expedited four-sequence protocol, sensitivity and specificity are comparable to CT while avoiding the detrimental effects of ionizing radiation. (orig.)

  2. Prospective evaluation of 18F-FACBC PET/CT and PET/MRI versus multiparametric MRI in intermediate- to high-risk prostate cancer patients (FLUCIPRO trial).

    Science.gov (United States)

    Jambor, Ivan; Kuisma, Anna; Kähkönen, Esa; Kemppainen, Jukka; Merisaari, Harri; Eskola, Olli; Teuho, Jarmo; Perez, Ileana Montoya; Pesola, Marko; Aronen, Hannu J; Boström, Peter J; Taimen, Pekka; Minn, Heikki

    2018-03-01

    The purpose of this study was to evaluate 18 F-FACBC PET/CT, PET/MRI, and multiparametric MRI (mpMRI) in detection of primary prostate cancer (PCa). Twenty-six men with histologically confirmed PCa underwent PET/CT immediately after injection of 369 ± 10 MBq 18 F-FACBC (fluciclovine) followed by PET/MRI started 55 ± 7 min from injection. Maximum standardized uptake values (SUV max ) were measured for both hybrid PET acquisitions. A separate mpMRI was acquired within a week of the PET scans. Logan plots were used to calculate volume of distribution (V T ). The presence of PCa was estimated in 12 regions with radical prostatectomy findings as ground truth. For each imaging modality, area under the curve (AUC) for detection of PCa was determined to predict diagnostic performance. The clinical trial registration number is NCT02002455. In the visual analysis, 164/312 (53%) regions contained PCa, and 41 tumor foci were identified. PET/CT demonstrated the highest sensitivity at 87% while its specificity was low at 56%. The AUC of both PET/MRI and mpMRI significantly (p PET/CT while no differences were detected between PET/MRI and mpMRI. SUV max and V T of Gleason score (GS) >3 + 4 tumors were significantly (p PET/CT and PET/MRI demonstrated true-positive findings in only 1/7 patients with metastatic lymph nodes. Quantitative 18 F-FACBC imaging significantly correlated with GS but failed to outperform MRI in lesion detection. 18 F-FACBC may assist in targeted biopsies in the setting of hybrid imaging with MRI.

  3. Benign and malignant skull-involved lesions: discriminative value of conventional CT and MRI combined with diffusion-weighted MRI.

    Science.gov (United States)

    Tu, Zhanhai; Xiao, Zebin; Zheng, Yingyan; Huang, Hongjie; Yang, Libin; Cao, Dairong

    2018-01-01

    Background Little is known about the value of computed tomography (CT) and magnetic resonance imaging (MRI) combined with diffusion-weighted imaging (DWI) in distinguishing malignant from benign skull-involved lesions. Purpose To evaluate the discriminative value of DWI combined with conventional CT and MRI for differentiating between benign and malignant skull-involved lesions. Material and Methods CT and MRI findings of 58 patients with pathologically proven skull-involved lesions (43 benign and 15 malignant) were retrospectively reviewed. Conventional CT and MRI characteristics and apparent diffusion coefficient (ADC) value of the two groups were evaluated and compared. Multivariate logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the differential performance of each parameter separately and together. Results The presence of cortical defects or break-through and ill-defined margins were associated with malignant skull-involved lesions (both P benign and malignant skull-involved lesions. Conclusion The combination of CT, MRI, and DWI can help to differentiate malignant from benign skull-involved lesions. CT + MRI + DWI offers optimal sensitivity, while DWI offers optimal specificity.

  4. MRI finding of hemangioblastomas

    International Nuclear Information System (INIS)

    Park, Seung Cheol; Oh, Min Cheol; Chung, Hwan Hoon; Seol, Hye Young; Lee, Nam Joon; Kim, Jung Hyuk

    1994-01-01

    The purpose of this study is to evaluate the findings of magnetic resonance imaging (MRI) of posterior fossa hemanangioblastoma and usefulness of contrast enhancement with Gd-DTPA. Seven patients with posterior fossa hemangioblastoma were studied with both pre- and post-enhanced MRI. The MR images were reviewed regarding the location, size, signal intensities of cysts and mural nodules, and their contrast enhancement pattern. Five tumors were located in cerebellar hemisphere, one in vermis, and one in posterior part of medulla. One patient with von Hippel-Lindau disease had a medullary hemangioblastoma with multiple pancreatic cysts. In 6 cases, the major portion of the tumor was cysts and had small mulkal nodules. The solid portion was relatively lange in one cases, cemprising half of the tumor cysts were oval shaped and their sized were 3-6.7 cm in diameter. In five cases(71%), septations were noted within the cysts. Cysts were isointense or slightly hyperintense on T1-weighted image and hyperintense on T2- weighted image compared with cerebrospinal fluid. Mural nodules were oval or rounded radiotherapy had better prognosis than those treated with radiotherapy alwas 0.5-2.5 cm in diameter. Mural nodules were isointense to gray matter. They were detected in five cases on T1-weighted images and one case on T2-weighted images. In two cases, vascular signal void area was noted in mural nodules. On contrast-enhanced T1-weighted images, all mural nodules were intensely enhanced. MRI provide to be a good diagnostic method to detect and characterize posterior fossa hemangioblastoma. The most common finding is Cystic posterior fossa lesion with enhancing mural nodule. Contrast enhancement is essential for specific diagnosis

  5. MRI case studies

    International Nuclear Information System (INIS)

    Huggett, S.; Barber, J.

    1989-01-01

    Three case studies are presented to show the value of magnetic resonance imaging used in conjunction with other imaging techniques. In each case MRI proved a vital diagnostic tool and superior to CT in showing firstly the haematoma in a patient with aphasia and right-sided weakness, secondly the size of the disc herniation in a patient with severe leg and ankle pains and thirdly the existence of a metastatic lesion in a patient with a previous history of breast cancer. 11 figs

  6. Tarsaltunnel syndrome - MRI diagnosis

    International Nuclear Information System (INIS)

    Trattnig, S.; Helbich, T.; Imhof, H.

    1995-01-01

    Clinical findings and symptoms of tarsal tunnel are commonly vague and diffuse and electrodiagnostic studies do not provide definitive diagnosis. MR imaging with its excellent soft tissue contrast can demonstrate clearly the anatomy of the tarsal tunnel and its contents. MRI is able to demonstrate a space-occypyinglesion and its relationship to the posterior tibial nerve and its branches. This information aids in surgical planning by determining the extent of the decompression required. MR imaging may also be used to follow up non-surgical causes of tarsal tunnel syndrome such as tenosynovitis. (orig.) [de

  7. Rabies, encephalomyelitis: MRI findings

    International Nuclear Information System (INIS)

    Peloso, Raul; Gonzalez, Roberto

    2002-01-01

    The authors present a 14 year old patient who started with walking and swallowing difficulty; followed by fever, abdominal and lower back pain. Mechanical breathing difficulties required a respiratory mechanic assistance. The diagnosis of Guillain-Barre syndrome was thought at first. Since the patient have had previous contact with a bat two months before the symptoms began, this suggested rabies as the main diagnosis, which was later confirmed by hair-bulb, cornea, oral mucosa and salival immunofluorescence. The brain and spinal cord MRI showed focal lesions in T2 and FLAIR sequences, compatible with encephalomyelitis. (author)

  8. Magnetic rubber inspection (MRI)

    International Nuclear Information System (INIS)

    Carro, L.

    1997-01-01

    Magnetic Rubber Inspection (MRI) was developed to inspect for small cracks and flaws encountered in high performance aircraft. A formula of very fine magnetic particles immersed in a room temperature curing rubber is catalysed and poured into dams (retainers) on the surface of the part to be inspected. Inducing a magnetic field then causes the particles to be drawn to discontinuities in the component under test. These indicating particles are held to the discontinuity by magnetic attraction, as the rubber cures. The solid rubber cast (Replica) is then removed and examined under a microscope for indicating lines of particle concentrations. 3 refs., 6 figs

  9. Ovarian cysts on prenatal MRI

    International Nuclear Information System (INIS)

    Nemec, Ursula; Nemec, Stefan F.; Bettelheim, Dieter; Brugger, Peter C.; Horcher, Ernst; Schöpf, Veronika; Graham, John M.; Rimoin, David L.; Weber, Michael; Prayer, Daniela

    2012-01-01

    Objective: Ovarian cysts are the most frequently encountered intra-abdominal masses in females in utero. They may, at times, require perinatal intervention. Using magnetic resonance imaging (MRI) as an adjunct to ultrasonography (US) in prenatal diagnosis, we sought to demonstrate the ability to visualize ovarian cysts on prenatal MRI. Materials and methods: This retrospective study included 17 fetal MRI scans from 16 female fetuses (23–37 gestational weeks) with an MRI diagnosis of ovarian cysts after suspicious US findings. A multiplanar MRI protocol was applied to image and to characterize the cysts. The US and MRI findings were compared, and the prenatal findings were compared with postnatal imaging findings or histopathology. Results: Simple ovarian cysts were found in 10/16 cases and complex cysts in 7/16 cases, including one case with both. In 11/16 (69%) cases, US and MRI diagnoses were in agreement, and, in 5/16 (31%) cases, MRI specified or expanded the US diagnosis. In 6/16 cases, postnatal US showed that the cysts spontaneously resolved or decreased in size, and in 1/16 cases, postnatal imaging confirmed a hemorrhagic cyst. In 4/16 cases, the prenatal diagnoses were confirmed by surgery/histopathology, and for the rest, postnatal correlation was not available. Conclusion: Our results illustrate the MRI visualization of ovarian cysts in utero. In most cases, MRI will confirm the US diagnosis. In certain cases, MRI may provide further diagnostic information, additional to US, which is the standard technique for diagnosis, monitoring, and treatment planning.

  10. Ovarian cysts on prenatal MRI

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Ursula [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Nemec, Stefan F., E-mail: stefan.nemec@meduniwien.ac.at [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Medical Genetics Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, PACT Suite 400, Los Angeles, CA 90048 (United States); Bettelheim, Dieter [Department of Obstetrics and Gynaecology, Division of Prenatal Diagnosis and Therapy, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Brugger, Peter C. [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University Vienna, Waehringerstrasse 13, A-1090 Vienna (Austria); Horcher, Ernst [Department of Pediatric Surgery, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Schoepf, Veronika [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Graham, John M.; Rimoin, David L. [Medical Genetics Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, PACT Suite 400, Los Angeles, CA 90048 (United States); Weber, Michael; Prayer, Daniela [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2012-08-15

    Objective: Ovarian cysts are the most frequently encountered intra-abdominal masses in females in utero. They may, at times, require perinatal intervention. Using magnetic resonance imaging (MRI) as an adjunct to ultrasonography (US) in prenatal diagnosis, we sought to demonstrate the ability to visualize ovarian cysts on prenatal MRI. Materials and methods: This retrospective study included 17 fetal MRI scans from 16 female fetuses (23-37 gestational weeks) with an MRI diagnosis of ovarian cysts after suspicious US findings. A multiplanar MRI protocol was applied to image and to characterize the cysts. The US and MRI findings were compared, and the prenatal findings were compared with postnatal imaging findings or histopathology. Results: Simple ovarian cysts were found in 10/16 cases and complex cysts in 7/16 cases, including one case with both. In 11/16 (69%) cases, US and MRI diagnoses were in agreement, and, in 5/16 (31%) cases, MRI specified or expanded the US diagnosis. In 6/16 cases, postnatal US showed that the cysts spontaneously resolved or decreased in size, and in 1/16 cases, postnatal imaging confirmed a hemorrhagic cyst. In 4/16 cases, the prenatal diagnoses were confirmed by surgery/histopathology, and for the rest, postnatal correlation was not available. Conclusion: Our results illustrate the MRI visualization of ovarian cysts in utero. In most cases, MRI will confirm the US diagnosis. In certain cases, MRI may provide further diagnostic information, additional to US, which is the standard technique for diagnosis, monitoring, and treatment planning.

  11. Interference between PET and MRI sub-systems in a silicon-photomultiplier-based PET/MRI system

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Hatazawa, Jun; Aoki, Masaaki; Sugiyama, Eiji; Watabe, Tadashi; Imaizumi, Masao; Shimosegawa, Eku

    2011-01-01

    The silicon-photomultiplier (Si-PM) is a promising photodetector, especially for integrated PET/MRI systems, due to its small size, high gain, and low sensitivity to static magnetic fields. The major problem using a Si-PM-based PET system within the MRI system is the interference between the PET and MRI units. We measured the interference by combining a Si-PM-based PET system with a permanent-magnet MRI system. When the RF signal-induced pulse height exceeded the lower energy threshold level of the PET system, interference between the Si-PM-based PET system and MRI system was detected. The prompt as well as the delayed coincidence count rates of the Si-PM-based PET system increased significantly. These noise counts produced severe artifacts on the reconstructed images of the Si-PM-based PET system. In terms of the effect of the Si-PM-based PET system on the MRI system, although no susceptibility artifact was observed on the MR images, electronic noise from the PET detector ring was detected by the RF coil and reduced the signal-to-noise ratio (S/N) of the MR images. The S/N degradation of the MR images was reduced when the distance between the RF coil and the Si-PM-based PET system was increased. We conclude that reducing the interference between the PET and MRI systems is essential for achieving the optimum performance of integrated Si-PM PET/MRI systems.

  12. Detection of early subclinical lung disease in children with cystic fibrosis by lung ventilation imaging with hyperpolarised gas MRI.

    Science.gov (United States)

    Marshall, Helen; Horsley, Alex; Taylor, Chris J; Smith, Laurie; Hughes, David; Horn, Felix C; Swift, Andrew J; Parra-Robles, Juan; Hughes, Paul J; Norquay, Graham; Stewart, Neil J; Collier, Guilhem J; Teare, Dawn; Cunningham, Steve; Aldag, Ina; Wild, Jim M

    2017-08-01

    Hyperpolarised 3 He ventilation-MRI, anatomical lung MRI, lung clearance index (LCI), low-dose CT and spirometry were performed on 19 children (6-16 years) with clinically stable mild cystic fibrosis (CF) (FEV 1 >-1.96), and 10 controls. All controls had normal spirometry, MRI and LCI. Ventilation-MRI was the most sensitive method of detecting abnormalities, present in 89% of patients with CF, compared with CT abnormalities in 68%, LCI 47% and conventional MRI 22%. Ventilation defects were present in the absence of CT abnormalities and in patients with normal physiology, including LCI. Ventilation-MRI is thus feasible in young children, highly sensitive and provides additional information about lung structure-function relationships. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. Sacral Ewing's Sarcoma and Challenges in it's Diagnosis on MRI

    Directory of Open Access Journals (Sweden)

    Albert D'Souza

    2009-01-01

    Full Text Available A 15-yr old boy presented with low backache for 4 months associated with weakness of left lower limb. MRI of lumbosacral spine showed a sacral lesion with intraspinal and presacral soft tissue extension with neural compression. A diagnosis of tuberculosis was considered in the view of high prevalence in this part of the world, however biopsy revealed Ewing's sarcoma. Ewing's tumor of sacrum is rare, but should be suspected in low backache in children. Differential diagnosis for a sacral lesion includes tuberculosis, pyogenic osteomyelitis, lymphoma, chordoma, osteosarcoma and Ewing's sarcoma. MRI is sensitive in detecting these lesions but is nonspecific requiring histopathological examination for confirmation.

  14. Screening for lung cancer: Does MRI have a role?

    International Nuclear Information System (INIS)

    Biederer, Juergen; Ohno, Yoshiharu; Hatabu, Hiroto; Schiebler, Mark L.; Beek, Edwin J.R. van; Vogel-Claussen, Jens; Kauczor, Hans-Ulrich

    2017-01-01

    Highlights: • From a technical point of view, the feasibility of using MRI for lung cancer screening is evident. • Experience with the clinical use of lung MRI is growing, standardized protocols are available. • If lung cancer screening becomes effective, there will be an opportunity for MRI as primary screening modality or adjunct to CT. • Validation of better patient outcomes (test effectiveness) for the use of MRI is still missing, therefore. • A simultaneous evaluation of MRI should be embedded into any future prospective lung cancer screening trials. - Abstract: While the inauguration of national low dose computed tomographic (LDCT) lung cancer screening programs has started in the USA, other countries remain undecided, awaiting the results of ongoing trials. The continuous technical development achieved by stronger gradients, parallel imaging and shorter echo time has made lung magnetic resonance imaging (MRI) an interesting alternative to CT. For the detection of solid lesions with lung MRI, experimental and clinical studies have shown a threshold size of 3–4 mm for nodules, with detection rates of 60–90% for lesions of 5–8 mm and close to 100% for lesions of 8 mm or larger. From experimental work, the sensitivity for infiltrative, non-solid lesions would be expected to be similarly high as that for solid lesions, but the published data for the MRI detection of lepidic growth type adenocarcinoma is sparse. Moreover, biological features such as a longer T2 time of lung cancer tissue, tissue compliance and a more rapid uptake of contrast material compared to granulomatous diseases, in principle should allow for the multi-parametric characterization of lung pathology. Experience with the clinical use of lung MRI is growing. There are now standardized protocols which are easy to implement on current scanner hardware configurations. The image quality has become more robust and currently ongoing studies will help to further contribute experience

  15. Screening for lung cancer: Does MRI have a role?

    Energy Technology Data Exchange (ETDEWEB)

    Biederer, Juergen, E-mail: Juergen.biederer@uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital of Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Lung ResearchCenter (DZL), Im Neuenheimer Feld 430, 69120 Heidelberg (Germany); Radiologie Darmstadt, Gross-Gerau County Hospital, 64521 Gross-Gerau (Germany); Ohno, Yoshiharu [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Centre, Kobe University Graduate School of Medicine, Kobe (Japan); Hatabu, Hiroto [Department of Radiology, Brigham and Women’s Hospital and Harvard Medical School, Boston, MA (United States); Schiebler, Mark L. [Department of Radiology, UW-Madison School of Medicine and Public Health, Madison, WI (United States); Beek, Edwin J.R. van [Clinical Research Imaging Centre, University of Edinburgh, Scotland (United Kingdom); Vogel-Claussen, Jens [Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover (Germany); Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover (Germany); Kauczor, Hans-Ulrich [Department of Diagnostic and Interventional Radiology, University Hospital of Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Lung ResearchCenter (DZL), Im Neuenheimer Feld 430, 69120 Heidelberg (Germany)

    2017-01-15

    Highlights: • From a technical point of view, the feasibility of using MRI for lung cancer screening is evident. • Experience with the clinical use of lung MRI is growing, standardized protocols are available. • If lung cancer screening becomes effective, there will be an opportunity for MRI as primary screening modality or adjunct to CT. • Validation of better patient outcomes (test effectiveness) for the use of MRI is still missing, therefore. • A simultaneous evaluation of MRI should be embedded into any future prospective lung cancer screening trials. - Abstract: While the inauguration of national low dose computed tomographic (LDCT) lung cancer screening programs has started in the USA, other countries remain undecided, awaiting the results of ongoing trials. The continuous technical development achieved by stronger gradients, parallel imaging and shorter echo time has made lung magnetic resonance imaging (MRI) an interesting alternative to CT. For the detection of solid lesions with lung MRI, experimental and clinical studies have shown a threshold size of 3–4 mm for nodules, with detection rates of 60–90% for lesions of 5–8 mm and close to 100% for lesions of 8 mm or larger. From experimental work, the sensitivity for infiltrative, non-solid lesions would be expected to be similarly high as that for solid lesions, but the published data for the MRI detection of lepidic growth type adenocarcinoma is sparse. Moreover, biological features such as a longer T2 time of lung cancer tissue, tissue compliance and a more rapid uptake of contrast material compared to granulomatous diseases, in principle should allow for the multi-parametric characterization of lung pathology. Experience with the clinical use of lung MRI is growing. There are now standardized protocols which are easy to implement on current scanner hardware configurations. The image quality has become more robust and currently ongoing studies will help to further contribute experience

  16. Value of breast MRI as supplement to mammography and sonography for high risk breast cancer patients

    International Nuclear Information System (INIS)

    Schlossbauer, T.; Hellerhoff, K.; Reiser, M.

    2008-01-01

    The aim of this study is to give an overview on early detection of breast cancer in patients with an increased risk of breast cancer. Sensitivities and diagnostic accuracies of breast MRI, mammography and ultrasound were compared. A systematic literature search of the past 3 years was performed. Studies which compared breast imaging modalities and used image-guided biopsy results as standard of reference were included. Patients included had to have had an increased lifetime risk for breast cancer (>15%). Regarding sensitivity and diagnostic accuracy, breast MRI performed best in comparison to the other modalities within this collective of patients. Sensitivities ranged from 71-100%, 0-78%, and 13-65%, for MRI, mammography, and ultrasound, respectively Breast MRI is a well established tool for screening in patients at high risk for developing breast cancer and is a valuable supplement to mammography and ultrasound within this selected cohort of patients. (orig.) [de

  17. Optimal use of MRI in clinical trials, clinical care and clinical registries of patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Møller-Bisgaard, Signe

    2014-01-01

    the benefits of including MRI in treat-to-target strategies. The benefits of incorporating MRI into clinical registries are not yet known, but may include improved knowledge about the real-life advantages of MRI, as well as opportunities to develop better clinical and laboratory composite measures to monitor......Magnetic resonance imaging (MRI) clearly is more sensitive than clinical examination and conventional radiography (x-ray) for detection of inflammation (synovitis, bone marrow oedema (osteitis) and tenosynovitis) and damage (bone erosion and cartilage loss/joint space narrowing) in patients...... with rheumatoid arthritis (RA). The question is when and how MRI should be used. The present article reviews our knowledge about, and provides suggestions for, the use of MRI in clinical trials, clinical care and clinical registries. In clinical trials, the OMERACT RA MRI scoring system (RAMRIS) is a thoroughly...

  18. MRI in intraspinal tuberculosis

    International Nuclear Information System (INIS)

    Gupta, R.K.; Gupta, S.; Kumar, S.; Kohli, A.; Misra, U.K.; Gujral, R.B.

    1994-01-01

    We studied 20 patients with intraspinal tuberculosis (TB), to characterise the MRI features of tuberculous meningitis and myelitis. MRI leptomeningitis and intramedullary involvement in 11 patients, intramedullary lesions alone in 5, leptomeningitis alone in 2, and isolated extradural disease in 2. TB leptomeningitis was characterised by loculation of the cerebrospinal fluid (CSF), nerve root thickening and clumping (seen only in the lumbar region) or complete obliteration of the subarachnoid space on unenhanced images. Gd-DTPA-enhanced images proved useful in 6 cases, revealing linear enhancement of the surface of the spinal cord and nerve roots or plaque-like enhancement of the dura-arachnoid mater complex. Intramedullary lesions included tuberculomas (8), cord oedema (5) and cavitation (3). In seven cases of intramedullary tuberculoma multiple lesions with skip areas were seen, without significant cord swelling. One patient had an isolated lesion in the conus medullaris. The lesions were iso- or hypointense on T1-weighted images, iso-, hypo- or hyperintense on T2-weighted images and showed rim or nodular enhancement with contrast medium. (orig.)

  19. Musculoskeletal MRI: dedicated systems

    International Nuclear Information System (INIS)

    Masciocchi, C.; Barile, A.; Satragno, L.

    2000-01-01

    The ''dedicated'' MRI units have characteristics of high diagnostic accuracy and lower installation and management costs as compared with whole-body systems. The dedicated MRI units are easy to install. The low weight allows their installation also under unfavorable circumstances. In a dedicated system cost-effectiveness and ease of installation must be accompanied by the capability of providing high-quality images. In our experience, the high number of examinations performed, the most part of which provided with the surgical controls, allowed an accurate evaluation of the diagnostic potentialities of the dedicated magnet. We were not able to perform the examinations in only 3 % of cases due to the physical shape of the patient and the clinical condition of the patient which may hinder the correct positioning of the limb. The overlapping of the diagnostic accuracy of the E-scan and Artoscan units in the study of the lower limbs, compared with whole-body units and surgery, prompted us to exploit the potentialities of the E-Scan in the study of the shoulder. We had a good correlation between E-Scan, whole-body units, and surgical findings, which confirmed the high diagnostic accuracy of the dedicated system. In conclusion, in our experience carried out in the musculoskeletal system, the dedicated magnets showed promising results. Their diagnostic reliability and utility was comparable to that obtained from conventional units operating at higher magnetic fields. (orig.)

  20. Cardiovascular MRI with ferumoxytol

    International Nuclear Information System (INIS)

    Finn, J.P.; Nguyen, K.-L.; Han, F.; Zhou, Z.; Salusky, I.; Ayad, I.; Hu, P.

    2016-01-01

    The practice of contrast-enhanced magnetic resonance angiography (CEMRA) has changed significantly in the span of a decade. Concerns regarding gadolinium (Gd)-associated nephrogenic systemic fibrosis in those with severely impaired renal function spurred developments in low-dose CEMRA and non-contrast MRA as well as efforts to seek alternative MR contrast agents. Originally developed for MR imaging use, ferumoxytol (an ultra-small superparamagnetic iron oxide nanoparticle), is currently approved by the US Food and Drug Administration for the treatment of iron deficiency anaemia in adults with renal disease. Since its clinical availability in 2009, there has been rising interest in the scientific and clinical use of ferumoxytol as an MR contrast agent. The unique physicochemical and pharmacokinetic properties of ferumoxytol, including its long intravascular half-life and high r 1 relaxivity, support a spectrum of MRI applications beyond the scope of Gd-based contrast agents. Moreover, whereas Gd is not found in biological systems, iron is essential for normal metabolism, and nutritional iron deficiency poses major public health challenges worldwide. Once the carbohydrate shell of ferumoxytol is degraded, the elemental iron at its core is incorporated into the reticuloendothelial system. These considerations position ferumoxytol as a potential game changer in the field of CEMRA and MRI. In this paper, we aim to summarise our experience with the cardiovascular applications of ferumoxytol and provide a brief synopsis of ongoing investigations on ferumoxytol-enhanced MR applications.

  1. MRI of the cartilage

    Energy Technology Data Exchange (ETDEWEB)

    Imhof, H.; Noebauer-Huhmann, I.-M.; Krestan, C.; Gahleitner, A.; Marlovits, S.; Trattnig, S. [Department of Osteology, Universitaetklinik fuer Radiodiagnostik, AKH-Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Sulzbacher, I. [Universitaetsklinik fuer Pathologie Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)

    2002-11-01

    With the introduction of fat-suppressed gradient-echo and fast spin-echo (FSE) sequences in clinical routine MR visualization of the hyaline articular cartilage is routinely possible in the larger joints. While 3D gradient-echo with fat suppression allows exact depiction of the thickness and surface of cartilage, FSE outlines the normal and abnormal internal structures of the hyaline cartilage; therefore, both sequences seem to be necessary in a standard MRI protocol for cartilage visualization. In diagnostically ambiguous cases, in which important therapeutic decisions are required, direct MR arthrography is the established imaging standard as an add-on procedure. Despite the social impact and prevalence, until recent years there was a paucity of knowledge about the pathogenesis of cartilage damage. With the introduction of high-resolution MRI with powerful surface coils and fat-suppression techniques, visualization of the articular cartilage is now routinely possible in many joints. After a short summary of the anatomy and physiology of the hyaline cartilage, the different MR imaging methods are discussed and recommended standards are suggested. (orig.)

  2. Getting an MRI (For Kids)

    Medline Plus

    Full Text Available ... A) Staying Safe Videos for Educators Search English Español Getting an MRI (Video) KidsHealth / For Kids / Getting an MRI (Video) Print en español Obtención de una resonancia magnética, RM (video) An ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician ... absolutely necessary for medical treatment. See the MRI Safety page for more information about pregnancy and MRI. ...

  4. Postmortem MRI of bladder agenesis

    Energy Technology Data Exchange (ETDEWEB)

    Barber, Brendan R. [St George' s Hospital, Radiology Department, London (United Kingdom); Weber, Martin A. [Great Ormond Street Hospital for Children, Department of Histopathology, London (United Kingdom); Bockenhauer, Detlef [Great Ormond Street Hospital for Children, Department of Nephrology, London (United Kingdom); Hiorns, Melanie P.; McHugh, Kieran [Great Ormond Street Hospital for Children, Radiology Department, London (United Kingdom)

    2011-01-15

    We report a 35-week preterm neonate with bladder agenesis and bilateral dysplastic kidneys. A suprapubic catheter was inadvertently inserted into one of the larger inferior cysts of the left dysplastic kidney. A postmortem MRI scan was performed with the findings being confirmed on autopsy. We are unaware of another postmortem MRI study demonstrating bladder agenesis. (orig.)

  5. Postmortem MRI of bladder agenesis

    International Nuclear Information System (INIS)

    Barber, Brendan R.; Weber, Martin A.; Bockenhauer, Detlef; Hiorns, Melanie P.; McHugh, Kieran

    2011-01-01

    We report a 35-week preterm neonate with bladder agenesis and bilateral dysplastic kidneys. A suprapubic catheter was inadvertently inserted into one of the larger inferior cysts of the left dysplastic kidney. A postmortem MRI scan was performed with the findings being confirmed on autopsy. We are unaware of another postmortem MRI study demonstrating bladder agenesis. (orig.)

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... fitting and has no metal fasteners. Guidelines about eating and drinking before an MRI exam vary with the specific exam and with the imaging facility. Unless you are told otherwise, you may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. People with the ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... absolutely necessary for medical treatment. See the MRI Safety page for more information about pregnancy and MRI. ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... can also provide functional information (fMRI) in selected cases. MR images of the brain and other cranial structures are clearer and more detailed than with other imaging methods. This detail makes MRI an invaluable tool in early diagnosis and evaluation of many conditions, ...

  12. Getting an MRI (For Kids)

    Medline Plus

    Full Text Available ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... English Español Getting an MRI (Video) KidsHealth / For Kids / Getting an MRI (Video) Print en español Obtención ...

  13. Musculoskeletal MRI findings of juvenile localized scleroderma

    Energy Technology Data Exchange (ETDEWEB)

    Eutsler, Eric P. [Nemours Children' s Health System/Alfred I. duPont Hospital for Children, Wilmington, DE (United States); Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Horton, Daniel B. [Nemours Children' s Health System/Alfred I. duPont Hospital for Children, Division of Rheumatology, Department of Pediatrics, Wilmington, DE (United States); Rutgers Robert Wood Johnson Medical School, Department of Pediatrics, New Brunswick, NJ (United States); Epelman, Monica [Nemours Children' s Health System/Nemours Children' s Hospital, Department of Medical Imaging, Orlando, FL (United States); Finkel, Terri [Nemours Children' s Health System/Nemours Children' s Hospital, Department of Pediatrics, Orlando, FL (United States); Averill, Lauren W. [Nemours Children' s Health System/Alfred I. duPont Hospital for Children, Wilmington, DE (United States)

    2017-04-15

    Juvenile localized scleroderma comprises a group of autoimmune conditions often characterized clinically by an area of skin hardening. In addition to superficial changes in the skin and subcutaneous tissues, juvenile localized scleroderma may involve the deep soft tissues, bones and joints, possibly resulting in functional impairment and pain in addition to cosmetic changes. There is literature documenting the spectrum of findings for deep involvement of localized scleroderma (fascia, muscles, tendons, bones and joints) in adults, but there is limited literature for the condition in children. We aimed to document the spectrum of musculoskeletal magnetic resonance imaging (MRI) findings of both superficial and deep juvenile localized scleroderma involvement in children and to evaluate the utility of various MRI sequences for detecting those findings. Two radiologists retrospectively evaluated 20 MRI studies of the extremities in 14 children with juvenile localized scleroderma. Each imaging sequence was also given a subjective score of 0 (not useful), 1 (somewhat useful) or 2 (most useful for detecting the findings). Deep tissue involvement was detected in 65% of the imaged extremities. Fascial thickening and enhancement were seen in 50% of imaged extremities. Axial T1, axial T1 fat-suppressed (FS) contrast-enhanced and axial fluid-sensitive sequences were rated most useful. Fascial thickening and enhancement were the most commonly encountered deep tissue findings in extremity MRIs of children with juvenile localized scleroderma. Because abnormalities of the skin, subcutaneous tissues and fascia tend to run longitudinally in an affected limb, axial T1, axial fluid-sensitive and axial T1-FS contrast-enhanced sequences should be included in the imaging protocol. (orig.)

  14. MRI for myocarditis; MRT bei Myokarditis

    Energy Technology Data Exchange (ETDEWEB)

    Gutberlet, M.; Luecke, C.; Krieghoff, C.; Hildebrand, L.; Steiner, J.; Adam, J.; Grotthoff, M.; Lehmkuhl, L. [Herzzentrum, Universitaet Leipzig, Abteilung fuer Diagnostische und Interventionelle Radiologie, Leipzig (Germany); Lurz, P.; Eitel, I.; Thiele, H. [Herzzentrum, Universitaet Leipzig, Abteilung Kardiologie, Leipzig (Germany)

    2013-01-15

    Cardiovascular magnetic resonance imaging (CMRI) has become the primary tool for the non-invasive assessment in patients with suspected myocarditis, especially after exclusion of acute coronary syndrome (ACS) for the differential diagnosis. Various MRI parameters are available which have different accuracies. Volumetric and functional ventricular assessment and the occurrence of pericardial effusion alone demonstrate only a poor sensitivity and specificity. The calculation of the T2-ratio (edema assessment), the early or global relative myocardial enhancement (gRE) and the late gadolinium enhancement (LGE), which represents irreversibly injured myocardium, are more specific parameters. All MRI parameters demonstrate the best accuracy in infarct-like acute myocarditis, whereas in chronic myocarditis sensitivity and specificity are less accurate. Therefore, a multisequential (at least two out of three parameters are positive) approach is recommended. The assessment of the value of newer, more quantitative MRI sequences, such as T1 and T2-mapping is still under investigation. (orig.) [German] Die kardiale MRT stellt die primaere nichtinvasive bildgebende Modalitaet bei Verdacht auf Myokarditis dar, insbesondere auch nach Ausschluss eines akuten Koronarsyndroms (ACS) zur Differenzialdiagnose. Verschiedene MR-Parameter mit unterschiedlicher Wertigkeit stehen zur Verfuegung. Die Beurteilung der Volumetrie und Ventrikelfunktion weisen ebenso wie der Nachweis eines Perikardergusses alleine nur eine geringe Sensitivitaet und Spezifitaet auf. Die spezifischeren MRT-Inflammationsparameter stellen die T2-Ratio (Oedemnachweis), die fruehe Kontrastmittelanreicherung bzw. das globale relative Enhancement (gRE) und die spaete Kontrastmittelanreicherung, das so genannte Late-Gadolinium-Enhancement (LGE) als Zeichen eines irreversiblen Myokardschadens dar. Alle MR-Parameter zeigen die beste diagnostische Genauigkeit bei einer ''infarktaehnlichen'' akuten

  15. Musculoskeletal MRI findings of juvenile localized scleroderma

    International Nuclear Information System (INIS)

    Eutsler, Eric P.; Horton, Daniel B.; Epelman, Monica; Finkel, Terri; Averill, Lauren W.

    2017-01-01

    Juvenile localized scleroderma comprises a group of autoimmune conditions often characterized clinically by an area of skin hardening. In addition to superficial changes in the skin and subcutaneous tissues, juvenile localized scleroderma may involve the deep soft tissues, bones and joints, possibly resulting in functional impairment and pain in addition to cosmetic changes. There is literature documenting the spectrum of findings for deep involvement of localized scleroderma (fascia, muscles, tendons, bones and joints) in adults, but there is limited literature for the condition in children. We aimed to document the spectrum of musculoskeletal magnetic resonance imaging (MRI) findings of both superficial and deep juvenile localized scleroderma involvement in children and to evaluate the utility of various MRI sequences for detecting those findings. Two radiologists retrospectively evaluated 20 MRI studies of the extremities in 14 children with juvenile localized scleroderma. Each imaging sequence was also given a subjective score of 0 (not useful), 1 (somewhat useful) or 2 (most useful for detecting the findings). Deep tissue involvement was detected in 65% of the imaged extremities. Fascial thickening and enhancement were seen in 50% of imaged extremities. Axial T1, axial T1 fat-suppressed (FS) contrast-enhanced and axial fluid-sensitive sequences were rated most useful. Fascial thickening and enhancement were the most commonly encountered deep tissue findings in extremity MRIs of children with juvenile localized scleroderma. Because abnormalities of the skin, subcutaneous tissues and fascia tend to run longitudinally in an affected limb, axial T1, axial fluid-sensitive and axial T1-FS contrast-enhanced sequences should be included in the imaging protocol. (orig.)

  16. Musculoskeletal MRI findings of juvenile localized scleroderma.

    Science.gov (United States)

    Eutsler, Eric P; Horton, Daniel B; Epelman, Monica; Finkel, Terri; Averill, Lauren W

    2017-04-01

    Juvenile localized scleroderma comprises a group of autoimmune conditions often characterized clinically by an area of skin hardening. In addition to superficial changes in the skin and subcutaneous tissues, juvenile localized scleroderma may involve the deep soft tissues, bones and joints, possibly resulting in functional impairment and pain in addition to cosmetic changes. There is literature documenting the spectrum of findings for deep involvement of localized scleroderma (fascia, muscles, tendons, bones and joints) in adults, but there is limited literature for the condition in children. We aimed to document the spectrum of musculoskeletal magnetic resonance imaging (MRI) findings of both superficial and deep juvenile localized scleroderma involvement in children and to evaluate the utility of various MRI sequences for detecting those findings. Two radiologists retrospectively evaluated 20 MRI studies of the extremities in 14 children with juvenile localized scleroderma. Each imaging sequence was also given a subjective score of 0 (not useful), 1 (somewhat useful) or 2 (most useful for detecting the findings). Deep tissue involvement was detected in 65% of the imaged extremities. Fascial thickening and enhancement were seen in 50% of imaged extremities. Axial T1, axial T1 fat-suppressed (FS) contrast-enhanced and axial fluid-sensitive sequences were rated most useful. Fascial thickening and enhancement were the most commonly encountered deep tissue findings in extremity MRIs of children with juvenile localized scleroderma. Because abnormalities of the skin, subcutaneous tissues and fascia tend to run longitudinally in an affected limb, axial T1, axial fluid-sensitive and axial T1-FS contrast-enhanced sequences should be included in the imaging protocol.

  17. Application of low field intensity joint MRI in ankle injury

    International Nuclear Information System (INIS)

    Zhang Zhenyu; Wang Wei

    2011-01-01

    Objective: To observe the diagnostic value of the low field intensity joint magnetic resonance imaging (MRI) in traumatic ankles. Methods: Through a retrospective examination and collection of 50 cases with complete information and checked by arthroscope or/and operated from Jan 2007 to Jun 2010, the diagnostic value ligament of the ankle joint, bone contusion,occult fracture, talus cartilage, and tendon could be evaluated. Cases of fracture for which could be diagnosed by X rays and CT were not included in this research. Results: The special low field intensity joint MRI had a high diagnostic sensitivity of 88.9% to ligamentum talofibulare anterius, but was only 50% sensitive to ligamentum calcaneofibulare. Its sensitivity to injury of ligamentum deltoideum and distal tibiofibular syndesmosis was up to 100%. Tendon injury, bone contusion and occult fracture could be exactly diagnosed. Its total sensitivity on talus cartilage traumatism was 70.6%. Its diagnosis sensitivity to talus cartilage traumatism at the 3rd-5th period by Mintz was 90%, with a lower one of 42.9% at the 1st-2nd period. Talus cartilage traumatism could be exactly predicted by osseous tissue dropsy below cartilage. Conclusion: The special low field intensity joint MRI is highly applicable to the diagnosis on ankle joint traumatism and facilitates clinical treatment. (authors)

  18. Tunable nanogap devices for ultra-sensitive electrochemical impedance biosensing

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yong [Department of Chemistry, Wannan Medical College, Wuhu 241002 (China); Guo, Zheng [Nanomaterials and Environmental Detection Laboratory, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei 230031 (China); Song, Jing-Jing; Huang, Qin-An; Zhu, Si-Wei [Department of Chemistry, Wannan Medical College, Wuhu 241002 (China); Huang, Xing-Jiu [Nanomaterials and Environmental Detection Laboratory, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei 230031 (China); Wei, Yan, E-mail: yanwei_wnmc@hotmail.com [Department of Chemistry, Wannan Medical College, Wuhu 241002 (China)

    2016-01-28

    A wealth of research has been available discussing nanogap devices for detecting very small quantities of biomolecules by observing their electrical behavior generally performed in dry conditions. We report that a gold nanogapped electrode with tunable gap length for ultra-sensitive detection of streptavidin based on electrochemical impedance technique. The gold nanogap is fabricated using simple monolayer film deposition and in-situ growth of gold nanoparticles in a traditional interdigitated array (IDA) microelectrode. The electrochemical impedance biosensor with a 25-nm nanogap is found to be ultra-sensitive to the specific binding of streptavidin to biotin. The binding of the streptavidin hinder the electron transfer between two electrodes, resulting in a large increase in electron-transfer resistance (R{sub et}) for operating the impedance. A linear relation between the relative R{sub et} and the logarithmic value of streptavidin concentration is observed in the concentration range from 1 pM (picomolar) to 100 nM (nanomolar). The lowest detectable concentration actually measured reaches 1 pM. We believe that such an electrochemical impedance nanogap biosensor provides a useful approach towards biomolecular detection that could be extended to a number of other systems. - Highlights: • A tunable gold nanogap device was used as to electrochemical impedance biosensor. • Linear range from 1 pM to 100 nM with LOD of 1 pM for streptavidin detection was obtained. • The nanogap devices exhibit a satisfactory precision, stability, and reproducibility. • The combination of electrochemical impedance technique and nanogap devices was achieved.

  19. Unenhanced breast MRI (STIR, T2-weighted TSE, DWIBS): An accurate and alternative strategy for detecting and differentiating breast lesions.

    Science.gov (United States)

    Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe; Moschetta, Marco

    2015-10-01

    To assess the role of STIR, T2-weighted TSE and DWIBS sequences for detecting and characterizing breast lesions and to compare unenhanced (UE)-MRI results with contrast-enhanced (CE)-MRI and histological findings, having the latter as the reference standard. Two hundred eighty consecutive patients (age range, 27-73 years; mean age±standard deviation (SD), 48.8±9.8years) underwent MR examination with a diagnostic protocol including STIR, T2-weighted TSE, THRIVE and DWIBS sequences. Two radiologists blinded to both dynamic sequences and histological findings evaluated in consensus STIR, T2-weighted TSE and DWIBS sequences and after two weeks CE-MRI images searching for breast lesions. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for UE-MRI and CE-MRI were calculated. UE-MRI results were also compared with CE- MRI. UE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 94%, 79%, 86%, 79% and 94%, respectively. CE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 98%, 83%, 90%, 84% and 98%, respectively. No statistically significant difference between UE-MRI and CE-MRI was found. Breast UE-MRI could represent an accurate diagnostic tool and a valid alternative to CE-MRI for evaluating breast lesions. STIR and DWIBS sequences allow to detect breast lesions while T2-weighted TSE sequences and ADC values could be useful for lesion characterization. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. A Technique for Generating Volumetric Cine MRI (VC-MRI)

    Science.gov (United States)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-01-01

    Purpose To develop a technique to generate on-board volumetric-cine MRI (VC-MRI) using patient prior images, motion modeling and on-board 2D-cine MRI. Methods One phase of a 4D-MRI acquired during patient simulation is used as patient prior images. 3 major respiratory deformation patterns of the patient are extracted from 4D-MRI based on principal-component-analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2D-cine MRI. The method was evaluated using both XCAT simulation of lung cancer patients and MRI data from four real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using Volume-Percent-Difference(VPD), Center-of-Mass-Shift(COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest(ROI) selection, patient breathing pattern change and noise on the estimation accuracy were also evaluated. Results Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was on average 8.43±1.52% and the COMS was on average 0.93±0.58mm across all time-steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR=20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions Preliminary studies demonstrated the