WorldWideScience

Sample records for photocathode lifetime studies

  1. DC photogun vacuum characterization through photocathode lifetime studies

    International Nuclear Information System (INIS)

    Marcy Stutzman; Joseph Grames; Matt Poelker; Kenneth Surles-Law; Philip Adderley

    2007-01-01

    Excellent vacuum is essential for long photocathode lifetimes in DC high voltage photoelectron guns. Vacuum Research at Thomas Jefferson National Accelerator Facility has focused on characterizing the existing vacuum systems at the CEBAF polarized photoinjector and on quantifying improvements for new systems. Vacuum chamber preprocessing, full activation of NEG pumps and NEG coating the chamber walls should improve the vacuum within the electron gun, however, pressure measurement is difficult at pressures approaching the extreme-high-vacuum (XHV) region and extractor gauge readings are not significantly different between the improved and original systems. The ultimate test of vacuum in a DC high voltage photogun is the photocathode lifetime, which is limited by the ionization and back-bombardment of residual gasses. Discussion will include our new load-locked gun design as well as lifetime measurements in both our operational and new photo-guns, and the correlations between measured vacuum and lifetimes will be investigated

  2. Correlation of CsK2Sb photocathode lifetime with antimony thickness

    Energy Technology Data Exchange (ETDEWEB)

    Mamun, M. A. [Department of Mechanical and Aerospace Engineering, Old Dominion University, Norfolk, Virginia 23529, USA; The Applied Research Center, Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606, USA; Hernandez-Garcia, C. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606, USA; Poelker, M. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606, USA; Elmustafa, A. A. [Department of Mechanical and Aerospace Engineering, Old Dominion University, Norfolk, Virginia 23529, USA; The Applied Research Center, Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606, USA

    2015-06-01

    CsK2Sb photocathodes with quantum efficiency on the order of 10% at 532 nm, and lifetime greater than 90 days at low voltage, were successfully manufactured via co-deposition of alkali species emanating from an effusion source. Photocathodes were characterized as a function of antimony layer thickness and alkali consumption, inside a vacuum chamber that was initially baked, but frequently vented without re-baking. Photocathode lifetime measured at low voltage is correlated with the antimony layer thickness. Photocathodes manufactured with comparatively thick antimony layers exhibited the best lifetime. We speculate that the antimony layer serves as a reservoir, or sponge, for the alkali.

  3. Correlation of CsK2Sb photocathode lifetime with antimony thickness

    Directory of Open Access Journals (Sweden)

    M. A. Mamun

    2015-06-01

    Full Text Available CsK2Sb photocathodes with quantum efficiency on the order of 10% at 532 nm, and lifetime greater than 90 days at low voltage, were successfully manufactured via co-deposition of alkali species emanating from an effusion source. Photocathodes were characterized as a function of antimony layer thickness and alkali consumption, inside a vacuum chamber that was initially baked, but frequently vented without re-baking. Photocathode lifetime measured at low voltage is correlated with the antimony layer thickness. Photocathodes manufactured with comparatively thick antimony layers exhibited the best lifetime. We speculate that the antimony layer serves as a reservoir, or sponge, for the alkali.

  4. Correlation of CsK{sub 2}Sb photocathode lifetime with antimony thickness

    Energy Technology Data Exchange (ETDEWEB)

    Mamun, M. A., E-mail: mmamu001@odu.edu; Elmustafa, A. A. [Department of Mechanical and Aerospace Engineering, Old Dominion University, Norfolk, Virginia 23529 (United States); The Applied Research Center, Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Hernandez-Garcia, C.; Poelker, M. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States)

    2015-06-01

    CsK{sub 2}Sb photocathodes with quantum efficiency on the order of 10% at 532 nm, and lifetime greater than 90 days at low voltage, were successfully manufactured via co-deposition of alkali species emanating from an effusion source. Photocathodes were characterized as a function of antimony layer thickness and alkali consumption, inside a vacuum chamber that was initially baked, but frequently vented without re-baking. Photocathode lifetime measured at low voltage is correlated with the antimony layer thickness. Photocathodes manufactured with comparatively thick antimony layers exhibited the best lifetime. We speculate that the antimony layer serves as a reservoir, or sponge, for the alkali.

  5. Measurements of Photocathode Operational Lifetime at Beam Currents up to 10 mA using an Improved DC High Voltage GaAs Photogun

    International Nuclear Information System (INIS)

    Grames, J.; Poelker, M.; Adderley, P.; Brittian, J.; Clark, J.; Hansknecht, J.; Machie, D.; Stutzman, M. L.; Surles-Law, K.

    2007-01-01

    This work extends past research at Jefferson Lab aimed at better appreciating the mechanisms that limit photocathode operational lifetime at high current (> 1 mA). Specifically, the performance of an improved 100 kV DC high voltage load locked photogun will be described. Although difficult to measure directly, we believe the new gun has better vacuum conditions compared to the original gun, as indicated by enhanced photocathode lifetimes exceeding 2000 C using a 1.55 mm diameter drive laser spot at the photocathode. In addition, the dependence of the lifetime on the laser spot size at the photocathode was measured and a charge density lifetime exceeding 106 C/cm2 was measured with a 0.32 mm laser spot diameter

  6. Measurements of photocathode operational lifetime at beam currents up to 10-mA using an improved DC high voltage GaAs photogun

    International Nuclear Information System (INIS)

    J. Grames; M. Poelker; P. Adderley; J. Brittian; J. Clark; J. Hansknecht; D. Machie; M.L. Stutzman; K. Surles-Law

    2007-01-01

    This work extends past research at Jefferson Lab aimed at better appreciating the mechanisms that limit photocathode operational lifetime at high current (> 1 mA). Specifically, the performance of an improved 100 kV DC high voltage load locked photogun will be described. Although difficult to measure directly, we believe the new gun has better vacuum conditions compared to the original gun, as indicated by enhanced photocathode lifetimes exceeding 2000 C using a 1.55 mm diameter drive laser spot at the photocathode. In addition, the dependence of the lifetime on the laser spot size at the photocathode was measured and a charge density lifetime exceeding 10 6 C/cm 2 was measured with a 0.32 mm laser spot diameter

  7. Kelvin probe studies of cesium telluride photocathode for AWA photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Wisniewski, Eric E., E-mail: ewisniew@anl.gov [High Energy Physics Division, Argonne National Laboratory, 9700 S. Cass, Lemont, IL 60439 (United States); Physics Department, Illinois Institute of Technology, 3300 South Federal Street, Chicago, IL 60616 (United States); Velazquez, Daniel [High Energy Physics Division, Argonne National Laboratory, 9700 S. Cass, Lemont, IL 60439 (United States); Physics Department, Illinois Institute of Technology, 3300 South Federal Street, Chicago, IL 60616 (United States); Yusof, Zikri, E-mail: zyusof@hawk.iit.edu [High Energy Physics Division, Argonne National Laboratory, 9700 S. Cass, Lemont, IL 60439 (United States); Physics Department, Illinois Institute of Technology, 3300 South Federal Street, Chicago, IL 60616 (United States); Spentzouris, Linda; Terry, Jeff [Physics Department, Illinois Institute of Technology, 3300 South Federal Street, Chicago, IL 60616 (United States); Sarkar, Tapash J. [Rice University, 6100 Main, Houston, TX 77005 (United States); Harkay, Katherine [Accelerator Science Division, Argonne National Laboratory, 9700 S. Cass, Lemont, IL 60439 (United States)

    2013-05-21

    Cesium telluride is an important photocathode as an electron source for particle accelerators. It has a relatively high quantum efficiency (>1%), is sufficiently robust in a photoinjector, and has a long lifetime. This photocathode is grown in-house for a new Argonne Wakefield Accelerator (AWA) beamline to produce high charge per bunch (≈50nC) in a long bunch train. Here, we present a study of the work function of cesium telluride photocathode using the Kelvin probe technique. The study includes an investigation of the correlation between the quantum efficiency and the work function, the effect of photocathode aging, the effect of UV exposure on the work function, and the evolution of the work function during and after photocathode rejuvenation via heating. -- Highlights: ► The correlation between Quantum Efficiency (QE) and work function. ► How QE and work function evolve together. ► Rejuvenation of the photocathode via heating and the effect on work function. ► The effects on the work function due to exposure to UV light.

  8. Masked Photocathode for Photoinjector

    International Nuclear Information System (INIS)

    Qiang, Ji

    2010-01-01

    In this research note, we propose a scheme to insert a photocathode inside a photoinjector for generating high brightness electron beam. Instead of mounting the photocathode onto the electrode, a masked electrode with small hole is used to shield the photocathode from the accelerating vacuum chamber. Using such a masked photocathode will make the replacement of photocathode material very simple by rotating the photocathode behind the mask into the hole. This will significantly increase the usage lifetime of a photocathode. Furthermore, this also helps reduce the dark current or secondary electron emission from the photocathode. The hole on the mask also provides a transverse cut-off to the Gaussian laser profile which can be beneficial from the beam dynamics point of view.

  9. Graphene shield enhanced photocathodes and methods for making the same

    Science.gov (United States)

    Moody, Nathan Andrew

    2014-09-02

    Disclosed are graphene shield enhanced photocathodes, such as high QE photocathodes. In certain embodiments, a monolayer graphene shield membrane ruggedizes a high quantum efficiency photoemission electron source by protecting a photosensitive film of the photocathode, extending operational lifetime and simplifying its integration in practical electron sources. In certain embodiments of the disclosed graphene shield enhanced photocathodes, the graphene serves as a transparent shield that does not inhibit photon or electron transmission but isolates the photosensitive film of the photocathode from reactive gas species, preventing contamination and yielding longer lifetime.

  10. Fabrication and Measurement of Low Work Function Cesiated Dispenser Photocathodes

    CERN Document Server

    Moody, Nathan A; Jensen, Kevin

    2005-01-01

    Photoinjector performance is a limiting factor in the continued development of high powered FELs and electron beam-based accelerators. Presently available photocathodes are plagued with limited efficiency and short lifetime in an RF-gun environment, due to contamination or evaporation of a photosensitive surface layer. An ideal photocathode should have high efficiency at long wavelengths, long lifetime in practical vacuum environments, and prompt emission. Cathodes with high efficiency typically have limited lifetime, and vice versa, and the needs of the photocathode are generally at odds with those of the drive laser. A potential solution is the low work function dispenser cathode, where lifetime issues are overcome by periodic in situ regeneration that restores the photosensitive surface layer, analogous to those used in the microwave power tube industry. This work reports on the fabrication techniques and performance of cesiated metal photocathodes and cesiated dispenser cathodes, with a focus on understan...

  11. S1 photocathode image converter tubes

    International Nuclear Information System (INIS)

    Gex, F.; Bauduin, P.; Hammes, C.; Horville, P.; Fleurot, N.; Nail, M.

    1984-08-01

    The S1 photocathode was the first cathode available for practical applications; in spite of this its mechanism of photoemission has remained enigmatic. S1 semi-transparent photocathode is the only one that can be used to study the 1.06 μm neodynium laser pulses of less than 10 ps duration. This recent application and the difficulties to manufacture stable and sensitive S1 photocathode at this wavelength gave rise to new researches which aim is to have a better knowledge of this structure. We first review the recent results obtained at the Paris Observatory (research sponsored by the CEA) and report on the lifetime in the 1-μm range of the photocathodes processed four years ago. In a second part we will try to analyse the researches which have been investigated during these last ten years in different laboratories to determine the role of the main constituants (silver particles, Co oxydes) and their contributions to photoemission in order to improve the sensitivity and the stability of S1 photocathode

  12. JAERI 200 kV electron gun with an NEA-GaAs photocathode

    International Nuclear Information System (INIS)

    Nishitani, Tomohiro; Minehara, Eisuke J.; Hajima, Ryoichi; Nagai, Ryoji; Sawamura, Masaru; Nishimori, Nobuyuki; Kikuzawa, Nobuhiro; Yamauchi, Toshihiko

    2004-01-01

    The photocathode DC-gun with high average current, low beam emittance and long operational lifetime is considered to be indispensable for ERL-FEL. We have started the development program of a 200 keV electron gun with the NEA-GaAs photocathode for the first time in JAERI. In order to long an NEA surface lifetime, the JAERI 200 kV electron gun system consists of a 200 kV DC-gun chamber on extreme high vacuum condition and an NEA activation chamber with load-lock system. We report the goal of photocathode DC-gun R and D and the schedule of a developmental program. (author)

  13. First operation of cesium telluride photocathodes in the TTF injector RF gun

    CERN Document Server

    Sertore, D; Flöttmann, K; Stephan, F; Zapfe, K; Michelato, P

    2000-01-01

    During the run 1998/1999 a new injector based on a laser-driven RF gun was brought in operation at the TESLA Test Facility (TTF) linac at DESY, in order to produce the beam structure and quality required either by TeV collider and SASE FEL experiments. High quantum efficiency cesium telluride photocathodes, prepared at Milano and transferred to DESY, have been successfully operated in the RF gun. A bunch charge of 50 nC, only limited by space charge effects, was achieved. The photocathodes have shown an operative lifetime of several months. A new cathode surface finishing has showed a promising decrease of the photocathode dark current. Measurements of dark current, quantum efficiency and lifetime are reported.

  14. Lifetime measurements using the Jefferson Lad Load-Lock Electron Gun

    International Nuclear Information System (INIS)

    J. Grames; P. Adderley; M. Baylac; J. Brittian; D. Charles; J. Clark; J. Hansknecht; M. Poelker; M. Stutzman; K. Surles-Law

    2000-01-01

    Lifetime measurements of bulk GaAs using a 100 kV load-lock electron gun and beam line were made. Initial tests used anodized samples to study lifetime under various conditions (gun vacuum, laser spot location, activated area). Subsequent tests used a mechanical mask to limit the active area and included improved monitoring of the gun chamber and beam line vacuum pressure. Results of these measurements support claims made at past workshops, namely photocathode lifetime improves when gun vacuum is enhanced and when electron emission from the edge of the photocathode is eliminated. The dependence upon laser spot location is less certain. Tests studying lifetime at higher beam intensity (I ∼ 8 mA) have begun

  15. Production and Studies of Photocathodes for High Intensity Electron Beams

    CERN Document Server

    Chevallay, E; Legros, P; Suberlucq, Guy; Trautner, H

    2000-01-01

    For short, high-intensity electron bunches, alkali-tellurides have proved to be a reliable photo-cathode material. Measurements of lifetimes in an rf gun of the CLIC Test Facility II at field strengths greater than 100 MV/m are presented. Before and after using them in this gun, the spectral response of the CS-Te and Rb-Te cathodes were determined with the help of an optical parametric oscillator. The behaviour of both materials can be described by Spicer's 3-step model. Whereas during the use the threshold for photo-emission in Cs-Te was shifted to higher proton energies, that of Rb-Te did not change. Our latest investigations on the stoichiometric ratio of the components are shown. The preparation of the photo-cathodes was monitored with 320 nm wavelength light , with the aim of improving the measurement sensitivity. The latest results on the protection of Cs-Te cathode surfaces with CsBr against pollution are summarized. New investigations on high mean current production are presented.,

  16. Polarization and charge limit studies of strained GaAs photocathodes

    International Nuclear Information System (INIS)

    Saez, P.J.

    1997-03-01

    This thesis presents studies on the polarization and charge limit behavior of electron beams produced by strained GaAs photocathodes. These photocathodes are the source of high-intensity, high-polarization electron beams used for a variety of high-energy physics experiments at the Stanford Linear Accelerator Center. Recent developments on P-type, biaxially-strained GaAs photocathodes have produced longitudinal polarization in excess of 80% while yielding beam intensities of ∼ 2.5 A/cm 2 at an operating voltage of 120 kV. The SLAC Gun Test Laboratory, which has a replica of the SLAC injector, was upgraded with a Mott polarimeter to study the polarization properties of photocathodes operating in a high-voltage DC gun. Both the maximum beam polarization and the maximum charge obtainable from these photocathodes have shown a strong dependence on the wavelength of illumination, on the doping concentration, and on the negative electron affinity levels. The experiments performed for this thesis included studying the effects of temperature, cesiation, quantum efficiency, and laser intensity on the polarization of high-intensity beams. It was found that, although low temperatures have been shown to reduce the spin relaxation rate in bulk semiconductors, they don't have a large impact on the polarization of thin photocathodes. It seems that the short active region in thin photocathodes does not allow spin relaxation mechanisms enough time to cause depolarization. Previous observations that lower QE areas on the photocathode yield higher polarization beams were confirmed. In addition, high-intensity, small-area laser pulses were shown to produce lower polarization beams. Based on these results, together with some findings in the existing literature, a new proposal for a high-intensity, high-polarization photocathode is given. It is hoped that the results of this thesis will promote further investigation on the properties of GaAs photocathodes

  17. Study of residual gas adsorption on GaN nanowire arrays photocathode

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Sihao; Liu, Lei, E-mail: liu1133_cn@sina.com.cn; Diao, Yu; Kong, Yike

    2017-05-01

    Highlights: • H{sub 2}O is more easily to absorb on the nanowire surface. • The work function increase after residual gas adsorption. • Bandgaps of the nanowire increase slightly. • Absorption coefficient is reduced and moves to higher energy side. - Abstract: In order to find out the influences of residual gas on GaN nanowire arrays photocathode, the optoelectronic properties of adsorption system are calculated on the basis of first principles. Results suggest that the residual gas adsorption will increase the work function and introduce a dipole moment with a direction from the nanowire to the adsorbates. The surface structures are changed and electrons transfer from nanowire to gas molecule. The bandgaps are enhanced after adsorption. Besides, the peak of absorption coefficients is reduced and moves to higher energy side. It is discovered that residual gas will drastically degrade the characteristics and lifetime of GaN nanowire arrays photocathode.

  18. Performance of the Brookhaven photocathode rf gun

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Fernow, R.C.; Fischer, J.; Fisher, A.S.; Gallardo, J.; Ingold, G.; Kirk, H.G.; Leung, K.P.; Malone, R.; Pogorelsky, I.; Srinivasan-Rao, T.; Rogers, J.; Tsang, T.; Sheehan, J.; Ulc, S.; Woodle, M.; Xie, J.; Zhang, R.S.; Lin, L.Y.; McDonald, K.T.; Russell, D.P.; Hung, C.M.; Wang, X.J.

    1991-01-01

    The Brookhaven Accelerator Test Facility (ATF) uses a photocathode rf gun to provide a high-brightness electron beam intended for FEL and laser-acceleration experiments. The rf gun consists of 1 1/2 cells driven at 2856 MHz in π-mode with a maximum cathode field of 100 MV/m. To achieve long lifetimes, the photocathode development concentrates on robust metals such as copper, yttrium and samarium. We illuminate these cathodes with a 10-ps, frequency-quadrupled Nd:YAG laser. We describe the initial operation of the gun, including measurements of transverse and longitudinal emittance, quantum efficiencies, and peak current. The results are compared to models

  19. Photocathode development

    International Nuclear Information System (INIS)

    Hinrichs, C.K.; Estrella, R.M.

    1979-01-01

    A research program for the development of photocathodes for use in streak image tubes is described. This is one task in the development of a high-resolution, high-speed x-ray streak camera system whose primary application is for diagnostics in underground nuclear testing. There are three objectives in the photocathode development program: (1) the development of new x-ray photocathodes compatible with the requirements of streak tubes; (2) the development of the capability to process high-quality visible light photocathodes as well as x-ray photocathodes; and (3) the design and construction of a transfer photocathode system. Design and construction of all the major components of the transfer photocathode system were completed. Assembly should be completed in early FY 80

  20. Cs2Te normal conducting photocathodes in the superconducting rf gun

    CERN Document Server

    Xiang, R; Buettig, H; Janssen, D; Justus, M; Lehnert, U; Michel, P; Murcek, P; Schamlott, A; Schneider, Ch; Schurig, R; Staufenbiel, F; Teichert, J

    2010-01-01

    The superconducting radio frequency photoinjector (SRF gun) is one of the latest applications of superconducting rf technology in the accelerator field. Since superconducting photocathodes with high quantum efficiency are yet unavailable, normal conducting cathode material is the main choice for SRF photoinjectors. However, the compatibility between the photocathode and the cavity is one of the challenges for this concept. Recently, a SRF gun with Cs2Te cathode has been successfully operated in Forschungszentrum Dresden-Rossendorf. In this paper, we will present the physical properties of Cs2Te photocathodes in the SC cavity, such as the quantum efficiency, the lifetime, the rejuvenation, the charge saturation, and the dark current.

  1. Cs_{2}Te normal conducting photocathodes in the superconducting rf gun

    Directory of Open Access Journals (Sweden)

    R. Xiang

    2010-04-01

    Full Text Available The superconducting radio frequency photoinjector (SRF gun is one of the latest applications of superconducting rf technology in the accelerator field. Since superconducting photocathodes with high quantum efficiency are yet unavailable, normal conducting cathode material is the main choice for SRF photoinjectors. However, the compatibility between the photocathode and the cavity is one of the challenges for this concept. Recently, a SRF gun with Cs_{2}Te cathode has been successfully operated in Forschungszentrum Dresden-Rossendorf. In this paper, we will present the physical properties of Cs_{2}Te photocathodes in the SC cavity, such as the quantum efficiency, the lifetime, the rejuvenation, the charge saturation, and the dark current.

  2. Advances in DC photocathode electron guns

    International Nuclear Information System (INIS)

    Dunham M, Bruce; Heartmann, P.; Reza Kazimi; Hongxiu Liu; Poelker, B.M.; Price, J.S.; Rutt, P.M.; Schneider, W.J.; Sinclair K, Charles

    1998-01-01

    At Jefferson Lab, a DC photoemission gun using GaAs and GaAs-like cathodes provides a source of polarized electrons for the main accelerator. The gun is required to produce high average current with long operational lifetimes and high system throughout. Recent work has shown that careful control of the parameters affecting cathode lifetime lead to dramatic improvements in source operation. These conditions include vacuum and the related effect of ion back-bombardment, and precise control of all of the electrons emitted from the cathode. In this paper, the authors will review recent results and discuss implications for future photocathode guns

  3. Advances in DC photocathode electron guns

    International Nuclear Information System (INIS)

    Dunham, B. M.; Hartmann, P.; Kazimi, R.; Liu, H.; Poelker, B. M.; Price, J. S.; Rutt, P. M.; Schneider, W. J.; Sinclair, C. K.

    1999-01-01

    At Jefferson Lab, a DC photoemission gun using GaAs and GaAs-like cathodes provides a source of polarized electrons for the main accelerator. The gun is required to produce high average current with long operational lifetimes and high system throughput. Recent work has shown that careful control of the parameters affecting cathode lifetime lead to dramatic improvements in source operation. These conditions include vacuum and the related effect of ion backbombardment, and precise control of all of the electrons emitted from the cathode. In this paper, we will review recent results and discuss implications for future photocathode guns

  4. Observation of Significant Quantum Efficiency Enhancement from a Polarized Photocathode with Distributed Bragg Reflector

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Shukui [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Poelker, Matthew [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Stutzman, Marcy L. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Chen, Yiqiao [SVT Associates, Inc., Eden Prairie, MN (United States); Moy, Aaron [SVT Associates, Inc., Eden Prairie, MN (United States)

    2015-09-01

    Polarized photocathodes with higher Quantum efficiency (QE) would help to reduce the technological challenge associated with producing polarized beams at milliampere levels, because less laser light would be required, which simplifies photocathode cooling requirements. And for a given amount of available laser power, higher QE would extend the photogun operating lifetime. The distributed Bragg reflector (DBR) concept was proposed to enhance the QE of strained-superlattice photocathodes by increasing the absorption of the incident photons using a Fabry-Perot cavity formed between the front surface of the photocathode and the substrate that includes a DBR, without compromising electron polarization. Here we present recent results showing QE enhancement of a GaAs/GaAsP strained-superlattice photocathode made with a DBR structure. Typically, a GaAs/GaAsP strained-superlattice photocathode without DBR provides a QE of 1%, at a laser wavelength corresponding to peak polarization. In comparison, the GaAs/GaAsP strained-superlattice photocathodes with DBR exhibited an enhancement of over 2 when the incident laser wavelength was tuned to meet the resonant condition for the Fabry-Perot resonator.

  5. Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

    CERN Document Server

    Siggins, T; Bohn, C L; Bullard, D; Douglas, D; Grippo, A; Gubeli, J; Krafft, G A; Yunn, B

    2001-01-01

    The performance of the 320 kV DC photocathode gun has met the design specifications for the 1 kW IR Demo FEL at Jefferson Lab. This gun has shown the ability to deliver high average current beam with outstanding lifetimes. The GaAs photocathode has delivered 135 pC per bunch, at a bunch repetition rate of 37.425 MHz, corresponding to 5 mA average CW current. In a recent cathode lifetime measurement, 20 h of CW beam was delivered with an average current of 3.1 mA and 211 C of total charge from a 0.283 cm sup 2 illuminated spot. The cathode showed a 1/e lifetime of 58 h and a 1/e extracted charge lifetime of 618 C. We have achieved quantum efficiencies of 5% from a GaAs wafer that has been in service for 13 months delivering in excess 2400 C with only three activation cycles.

  6. Photocathode

    Energy Technology Data Exchange (ETDEWEB)

    Opachich, Yekaterina; MacPhee, Andrew

    2017-12-05

    A photocathode designs that leverage the grazing incidence geometry yield improvements through the introduction of recessed structures, such as cones, pyramids, pillars or cavities to the photocathode substrate surface. Improvements in yield of up to 20 times have been shown to occur in grazing incidence geometry disclosed herein due to a larger path length of the X-ray photons which better matches the secondary electron escape depth within the photocathode material. A photocathode includes a substrate having a first side and a second side, the first side configured to receive x-ray energy and the second side opposing the first side. A structured surface is associated with the second side of the substrate such that the structured surface includes a plurality of recesses from the second side of the substrate into the substrate.

  7. Advances in DC photocathode electron guns

    International Nuclear Information System (INIS)

    Dunham, B.M.; Hartmann, P.; Kazimi, R.; Liu, H.; Poelker, B.M.; Price, J.S.; Rutt, P.M.; Schneider, W.J.; Sinclair, C.K.

    1999-01-01

    At Jefferson Lab, a DC photoemission gun using GaAs and GaAs-like cathodes provides a source of polarized electrons for the main accelerator. The gun is required to produce high average current with long operational lifetimes and high system throughput. Recent work has shown that careful control of the parameters affecting cathode lifetime lead to dramatic improvements in source operation. These conditions include vacuum and the related effect of ion backbombardment, and precise control of all of the electrons emitted from the cathode. In this paper, we will review recent results and discuss implications for future photocathode guns. copyright 1999 American Institute of Physics

  8. Effect of Sb thickness on the performance of bialkali-antimonide photocathodes

    Energy Technology Data Exchange (ETDEWEB)

    Mamun, Md Abdullah A., E-mail: mmamu001@odu.edu; Elmustafa, Abdelmageed A. [Department of Mechanical and Aerospace Engineering, Old Dominion University, Norfolk, Virginia 23529 and The Applied Research Center, Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Hernandez-Garcia, Carlos; Mammei, Russell; Poelker, Matthew [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States)

    2016-03-15

    The alkali species Cs and K were codeposited using an effusion source, onto relatively thick layers of Sb (50 nm to ∼7 μm) grown on GaAs and Ta substrates inside a vacuum chamber that was baked and not-vented, and also baked and vented with clean dry nitrogen but not rebaked. The characteristics of the Sb films, including sticking probability, surface roughness, grain size, and crystal properties were very different for these conditions, yet comparable values of photocathode yield [or quantum efficiency (QE)] at 284 V were obtained following codeposition of the alkali materials. Photocathodes manufactured with comparatively thick Sb layers exhibited the highest QE and the best 1/e lifetime. The authors speculate that the alkali codeposition enabled optimized stoichiometry for photocathodes manufactured using thick Sb layers, which could serve as a reservoir for the alkali materials.

  9. Experimental study on the production of high density electron bunches from a GaAs photocathode

    International Nuclear Information System (INIS)

    Calabrese, R.; Masoli, F.; Gong, J.M.; Guidi, V.; Tecchio, L.

    1991-01-01

    In order to obtain a high charge, low emittance electron source, useful for FEL electron injector and for e + e - collider experiments, we performed a test experiment on a gallium arsenide photocathode, activated by negative electron affinity technique and illuminated with a 10 ns long laser pulse of 532 nm wavelength. We measured a maximum charge delivered, at relatively low potentials, of about 18 nC/bunch. The mean lifetime is greater than 60 h. (orig.)

  10. Development status of a test stand for semiconductor photocathodes with 60 keV spin-polarized beamline

    Energy Technology Data Exchange (ETDEWEB)

    Kurichijanil, Neeraj; Enders, Joachim; Espig, Martin; Fritzsche, Yuliya; Heichelt, Dominic; Kaiser, Andreas; Roesch, Heidi; Wagner, Markus [Institut fuer Kernphysik, TU Darmstadt (Germany)

    2016-07-01

    A test facility for Photo-Cathode Activation, Test and Cleaning using atomic-Hydrogen (Photo-CATCH) is being constructed at TU Darmstadt's Institute for Nuclear Physics (IKP) which houses the Superconducting Darmstadt Linear Accelerator (S-DALINAC). In order to improve the performance of the SDALINAC's photoelectron source based on GaAs, systematic studies in terms of quantum efficiency (QE), cathode rejuvenation, lifetimes and polarization (P) have to be conducted on different photocathode types. These factors strongly depend on handling of the cathode, the vacuum condition in the chambers, cathode surface cleaning as well as preservation of stoichiometry, negative electron affinity (NEA) activation of the cathode and the type and structure of the semiconductor material. With Photo-CATCH, experiments such as atomic-hydrogen cleaning, multi-alkali and oxidant NEA activation of the cathode and tests of QE, P and lifetimes can be performed in an improved vacuum. Additionally, experiments with polarized-electron beams of up to 60 keV are foreseen.

  11. A Masked Photocathode in a Photoinjector

    OpenAIRE

    Qiang, Ji

    2011-01-01

    In this paper, we propose a masked photocathode inside a photoinjector for generating high brightness electron beam. Instead of mounting the photocathode onto an electrode, an electrode with small hole is used as a mask to shield the photocathode from the accelerating vacuum chamber. Using such a masked photocathode will make the replacement of photocathode material easy by rotating the photocathode behind the electrode into the hole. Furthermore, this helps reduce the dark current or seconda...

  12. Carbon nanotube based photocathodes

    International Nuclear Information System (INIS)

    Hudanski, Ludovic; Minoux, Eric; Schnell, Jean-Philippe; Xavier, Stephane; Pribat, Didier; Legagneux, Pierre; Gangloff, Laurent; Teo, Kenneth B K; Robertson, John; Milne, William I

    2008-01-01

    This paper describes a novel photocathode which is an array of vertically aligned multi-walled carbon nanotubes (MWCNTs), each MWCNT being associated with one p-i-n photodiode. Unlike conventional photocathodes, the functions of photon-electron conversion and subsequent electron emission are physically separated. Photon-electron conversion is achieved with p-i-n photodiodes and the electron emission occurs from the MWCNTs. The current modulation is highly efficient as it uses an optically controlled reconfiguration of the electric field at the MWCNT locations. Such devices are compatible with high frequency and very large bandwidth operation and could lead to their application in compact, light and efficient microwave amplifiers for satellite telecommunication. To demonstrate this new photocathode concept, we have fabricated the first carbon nanotube based photocathode using silicon p-i-n photodiodes and MWCNT bunches. Using a green laser, this photocathode delivers 0.5 mA with an internal quantum efficiency of 10% and an I ON /I OFF ratio of 30

  13. Development of a high average current polarized electron source with long cathode operational lifetime

    Energy Technology Data Exchange (ETDEWEB)

    C. K. Sinclair; P. A. Adderley; B. M. Dunham; J. C. Hansknecht; P. Hartmann; M. Poelker; J. S. Price; P. M. Rutt; W. J. Schneider; M. Steigerwald

    2007-02-01

    Substantially more than half of the electromagnetic nuclear physics experiments conducted at the Continuous Electron Beam Accelerator Facility of the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory) require highly polarized electron beams, often at high average current. Spin-polarized electrons are produced by photoemission from various GaAs-based semiconductor photocathodes, using circularly polarized laser light with photon energy slightly larger than the semiconductor band gap. The photocathodes are prepared by activation of the clean semiconductor surface to negative electron affinity using cesium and oxidation. Historically, in many laboratories worldwide, these photocathodes have had short operational lifetimes at high average current, and have often deteriorated fairly quickly in ultrahigh vacuum even without electron beam delivery. At Jefferson Lab, we have developed a polarized electron source in which the photocathodes degrade exceptionally slowly without electron emission, and in which ion back bombardment is the predominant mechanism limiting the operational lifetime of the cathodes during electron emission. We have reproducibly obtained cathode 1/e dark lifetimes over two years, and 1/e charge density and charge lifetimes during electron beam delivery of over 2?105???C/cm2 and 200 C, respectively. This source is able to support uninterrupted high average current polarized beam delivery to three experimental halls simultaneously for many months at a time. Many of the techniques we report here are directly applicable to the development of GaAs photoemission electron guns to deliver high average current, high brightness unpolarized beams.

  14. Protection of cesium-antimony photocathodes

    International Nuclear Information System (INIS)

    Buzulutskov, A.; Breskin, A.; Chechik, R.; Prager, M.; Shefer, E.

    1996-06-01

    In order to operate gaseous photomultipliers in the visible range it was suggested to protect sensitive photocathodes against contact to air and counting gases by their coating with a thin solid dielectric film. We present data on coating of cesium- antimony photocathodes with alkali-halide (NaI, CsI, CsF, NaF), oxide (SiO) and organic (hexatriacontane, calcium stearate) films. The photoelectron transmission through these films and their protection capability have been studied in detail. Cesium-antimony photocathodes are shown to withstand exposure to considerable doses of oxygen and dry air when coated with Nal films. This opens ways to their operation in gas media. (authors), 11 refs., 6 figs

  15. Development of a high average current polarized electron source with long cathode operational lifetime

    Directory of Open Access Journals (Sweden)

    C. K. Sinclair

    2007-02-01

    Full Text Available Substantially more than half of the electromagnetic nuclear physics experiments conducted at the Continuous Electron Beam Accelerator Facility of the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory require highly polarized electron beams, often at high average current. Spin-polarized electrons are produced by photoemission from various GaAs-based semiconductor photocathodes, using circularly polarized laser light with photon energy slightly larger than the semiconductor band gap. The photocathodes are prepared by activation of the clean semiconductor surface to negative electron affinity using cesium and oxidation. Historically, in many laboratories worldwide, these photocathodes have had short operational lifetimes at high average current, and have often deteriorated fairly quickly in ultrahigh vacuum even without electron beam delivery. At Jefferson Lab, we have developed a polarized electron source in which the photocathodes degrade exceptionally slowly without electron emission, and in which ion back bombardment is the predominant mechanism limiting the operational lifetime of the cathodes during electron emission. We have reproducibly obtained cathode 1/e dark lifetimes over two years, and 1/e charge density and charge lifetimes during electron beam delivery of over 2×10^{5}   C/cm^{2} and 200 C, respectively. This source is able to support uninterrupted high average current polarized beam delivery to three experimental halls simultaneously for many months at a time. Many of the techniques we report here are directly applicable to the development of GaAs photoemission electron guns to deliver high average current, high brightness unpolarized beams.

  16. CsI and some new photocathodes

    International Nuclear Information System (INIS)

    Anderson, D.F.; Kwan, S.; Peskov, V.

    1993-06-01

    A discussion of the possible sources of discrepancies in the measurements of the quantum efficiency of CsI photocathodes is presented. We propose that the major causes for disagreements in QE are due to the QE dependence on the current density extracted from the photocathode, on the electric field, and on the temperature of the photocathode. Preliminary results on TMAE enhanced GaAs and Si, plus TMAE protected CsTe and SbCs photocathodes, operated in gas, are also presented

  17. Proceedings of the workshop on photocathodes for polarized electron sources for accelerators

    International Nuclear Information System (INIS)

    Chatwell, M.; Clendenin, J.; Maruyama, T.; Schultz, D.

    1994-04-01

    Application of the GaAs polarized electron source to studies of surface magnetism; thermal stability of Cs on NES III-V-Photocathodes and its effect on quantum efficiency; AFEL accelerator; production and detection of SPIN polarized electrons; emittance measurements on a 100-keV beam from a GaAs photocathode electron gun; modern theory of photoemission and its applications to practical photocathodes; experimental studies of the charge limit phenomenon in GaAs photocathodes; new material for photoemission electron source; semiconductor alloy InGaAsP grown on GaAs substrate; NEA photocathode surface preparation; technology and physics; metalorganic chemical vapor deposition of GaAs-GaAsP spin-polarized photocathodes; development of photocathodes injectors for JLC-ATF; effect of radiation trapping on polarization of photoelectrons from semiconductors; and energy analysis of electrons emitted by a semiconductor photocathode

  18. RF gun using laser-triggered photocathode

    International Nuclear Information System (INIS)

    Akiyama, H.; Otake, Y.; Naito, T.; Takeuchi, Y.; Yoshioka, M.

    1992-01-01

    An RF gun using laser-triggered photocathode has many advantages as an injector of the linear colliders since it can generate a low emittance and high current pulsed beam. The experimental facility for the RF gun, such as an RF system, a laser system and a photocathode have been fabricated to study the fundamental characteristics. The dynamics of the RF gun has also studied by the 1D sheet beam model. (author)

  19. Proceedings of the workshop on photocathodes for polarized electron sources for accelerators. Revision

    Energy Technology Data Exchange (ETDEWEB)

    Chatwell, M.; Clendenin, J.; Maruyama, T.; Schultz, D. [eds.

    1994-04-01

    Application of the GaAs polarized electron source to studies of surface magnetism; thermal stability of Cs on NES III-V-Photocathodes and its effect on quantum efficiency; AFEL accelerator; production and detection of SPIN polarized electrons; emittance measurements on a 100-keV beam from a GaAs photocathode electron gun; modern theory of photoemission and its applications to practical photocathodes; experimental studies of the charge limit phenomenon in GaAs photocathodes; new material for photoemission electron source; semiconductor alloy InGaAsP grown on GaAs substrate; NEA photocathode surface preparation; technology and physics; metalorganic chemical vapor deposition of GaAs-GaAsP spin-polarized photocathodes; development of photocathodes injectors for JLC-ATF; effect of radiation trapping on polarization of photoelectrons from semiconductors; and energy analysis of electrons emitted by a semiconductor photocathode.

  20. A DFT study on NEA GaN photocathode with an ultrathin n-type Si-doped GaN cap layer

    Science.gov (United States)

    Xia, Sihao; Liu, Lei; Kong, Yike; Diao, Yu

    2016-10-01

    Due to the drawbacks of conventional negative electron affinity (NEA) GaN photocathodes activated by Cs or Cs/O, a new-type NEA GaN photocathodes with heterojunction surface dispense with Cs activation are proposed. This structure can be obtained through the coverage of an ultrathin n-type Si-doped GaN cap layer on the p-type Mg-doped GaN emission layer. The influences of the cap layer on the photocathode are calculated using DFT. This study indicates that the n-type cap layer can promote the photoemission characteristics of GaN photocathode and demonstrates the probability of the preparation of a NEA GaN photocathode with an n-type cap layer.

  1. Absorption of optical power in an S-20 photocathode

    CERN Document Server

    Harmer, S W

    2003-01-01

    By considering a monochromatic plane wave obliquely incident upon a planar layer of S-20 photocathode material, deposited upon a non-absorbing glass substrate, the distribution of optical power absorbed within the layer can be resolved. This is important to the question of photocathode efficiency, as the absorbed light excites photoelectrons within the photocathode which then may pass from the photocathode into the vacuum of the photomultiplier tube and be collected and multiplied. The calculation uses the measured complex permittivity of an extended red S-20 photocathode in the wavelength range, 375-900 nm. The results show that thin film effects are important within the photocathode, as they give rise to interesting power absorption profiles. This information is invaluable in predicting optimum photocathode thickness for wavelength selective applications. Electromagnetic waves that are obliquely incident upon the photocathode are also considered in both transverse electric and transverse magnetic polarizati...

  2. Study of the Quantum Efficiency of CsI Photocathodes Exposed to Oxygen and Water Vapour

    CERN Document Server

    Di Mauro, A; Piuz, François; Schyns, E M; Van Beelen, J B; Williams, T D

    2000-01-01

    The operation of CsI photocathodes in gaseous detectors requires special attention to the purity of the applied gas mixtures.We have studied the influence of oxygen and water vapour contaminations on the performance of CsI photocathodes for theALICE HMPID RICH prototype. Measurements were done through comparison of Cherenkov rings obtained from beamtests. Increased levels of oxygen and water vapour did not show any effect on the performance. The results of this studyfound a direct application in the way of storing CsI photocathodes over long periods nad in particular in the shipment of theHMPID prototype from CERN to the STAR experiment at BNL. (Abstract only available,full text to follow)

  3. Studies on a laser driven photoemissive high-brightness electron source and novel photocathodes

    International Nuclear Information System (INIS)

    Geng Rongli; Song Jinhu; Yu Jin

    1997-01-01

    A laser driven photoemissive high-brightness electron source at Beijing University is reported. Through a DC accelerating gap of 100 kV voltage, the device is capable of delivering high-brightness electron beam of 35-100 ps pulse duration when irradiated with a mode-locked YAG laser. The geometry of the gun is optimized with the aid of simulation codes EGUN and POISSON. The results of experimental studies on ion implanted photocathode and cesium telluride photocathode are given. The proposed laser driven superconducting RF gun is also discussed

  4. SSRL photocathode RF gun test stand

    International Nuclear Information System (INIS)

    Hernandez, M.; Baltay, M.; Boyce, A.

    1995-01-01

    A photocathode RF gun test stand designed for the production and study of high brightness electron beams will be constructed at SSRL. The beam will be generated from a laser driven third generation photocathode RF gun being developed in collaboration with BNL, LBL, and UCLA. The 3-5 [MeV] beam from the gun will be accelerated using a SLAC three meter S-band accelerator section, in order to achieve the desired low emittance beam, emittance compensation with solenoidal focusing will be employed

  5. Photoemission spectroscopy study of a multi-alkali photocathode

    CERN Document Server

    Ettema, A R H

    2000-01-01

    In this paper a photoemission study of the highest core levels of the elements and the electron escape barrier (work function) in a multi-alkali photocathode are presented. The core levels indicate that the alkali atoms are in an oxidized state and therefore the compound Na sub 2 KSb can be regarded as an ionic semiconductor. The measured escape barrier of the Cs sub 2 O surface layer is determined as 2.3 eV.

  6. Progress in ultrafast CsI-photocathode gaseous imaging photomultipliers

    International Nuclear Information System (INIS)

    Dagendorf, V.; Breskin, A.; Chechick, R.; Schmidt-Boecking, H.

    1991-04-01

    A large area low-pressure gas-filled UV-imaging photomultiplier with CsI photocathode is presented. The double step electron photomultiplier with a 10 torr CH 4 gas-filling enables stable high gain operation. The detection efficiency of photon in the wavelength range λ ∼ 170 nm (Xe scintilation light) is about 10% for 200 to 2000 nm thick photocathodes. We investigate the influence of various substrate materials, the thickness of the CsI-layer, the gas pressure and the gas composition on the performance of the photocathode. Furthermore we studied the stability of the photocathode under different operating conditions and its sensitivity to air. Measurements of the timing characteristic of the device yielded an ultimate time resolution of 350 ps (fwhm). (author)

  7. Intense electron beams from GaAs photocathodes as a tool for molecular and atomic physics

    International Nuclear Information System (INIS)

    Krantz, Claude

    2009-01-01

    We present cesium-coated GaAs photocathodes as reliable sources of intense, quasi-monoenergetic electron beams in atomic and molecular physics experiments. In long-time operation of the Electron Target of the ion storage ring TSR in Heidelberg, cold electron beams could be realised at steadily improving intensity and reliability. Minimisation of processes degrading the quantum efficiency allowed to increase the extractable current to more than 1mA at usable cathode lifetimes of 24 h or more. The benefits of the cold electron beam with respect to its application to electron cooling and electron-ion recombination experiments are discussed. Benchmark experiments demonstrate the superior cooling force and energy resolution of the photoelectron beam compared to its thermionic counterparts. The long period of operation allowed to study the long-time behaviour of the GaAs samples during multiple usage cycles at the Electron Target and repeated in-vacuum surface cleaning by atomic hydrogen exposure. An electron emission spectroscopy setup has been implemented at the photocathode preparation chamber of the Electron Target. Among others, this new facility opened the way to a novel application of GaAs (Cs) photocathodes as robust, ultraviolet-driven electron emitters. Based on this principle, a prototype of an electron gun, designed for implementation at the HITRAP setup at GSI, has been built and taken into operation successfully. (orig.)

  8. Intense electron beams from GaAs photocathodes as a tool for molecular and atomic physics

    Energy Technology Data Exchange (ETDEWEB)

    Krantz, Claude

    2009-10-28

    We present cesium-coated GaAs photocathodes as reliable sources of intense, quasi-monoenergetic electron beams in atomic and molecular physics experiments. In long-time operation of the Electron Target of the ion storage ring TSR in Heidelberg, cold electron beams could be realised at steadily improving intensity and reliability. Minimisation of processes degrading the quantum efficiency allowed to increase the extractable current to more than 1mA at usable cathode lifetimes of 24 h or more. The benefits of the cold electron beam with respect to its application to electron cooling and electron-ion recombination experiments are discussed. Benchmark experiments demonstrate the superior cooling force and energy resolution of the photoelectron beam compared to its thermionic counterparts. The long period of operation allowed to study the long-time behaviour of the GaAs samples during multiple usage cycles at the Electron Target and repeated in-vacuum surface cleaning by atomic hydrogen exposure. An electron emission spectroscopy setup has been implemented at the photocathode preparation chamber of the Electron Target. Among others, this new facility opened the way to a novel application of GaAs (Cs) photocathodes as robust, ultraviolet-driven electron emitters. Based on this principle, a prototype of an electron gun, designed for implementation at the HITRAP setup at GSI, has been built and taken into operation successfully. (orig.)

  9. Study of silicon tip photocathodes in DC and RF photo-injectors

    International Nuclear Information System (INIS)

    Jaber, Zakaria

    1999-01-01

    Nowadays the electron beams with a high intensity are particularly interesting in research and the applied physics. Producing such beams for which high intensity and low emittance are synonyms with efficiency, means developing new high luminosity electron sources, i.e. the photocathodes. This thesis, essentially experimental, is oriented in this way. After an introduction of Clermont-Ferrand and the LAL of Orsay experimental apparatus where the experiments took place, the chapter one presents the field emission and the photo-field emission. Then, we prove that the quantum efficiency of the photocathodes with silicon tips is higher for wavelengths near 800 nm. This fact is essential because it allows the use of lasers in the fundamental wavelength - Titan-Saphir for instance. In the chapter 2, we remind how the silicon tips are realized and how to improve surface conditions. Procedures and the surface analysis with the SEM and XPS are described. With a Nd-Yag laser, pumped with laser diode setting up with the participation of IRCOM Opticians of Limoges, the photocathode supplied 1 Ampere per pulse at a quantum efficiency of 0.25%. The description of this experiment and the results are the object of the chapter 3. The space charge outside the photocathode space prevents the electrons to go through. The Child-Langmuir formula limits the current with the DC gun at about 30 Ampere. To improve this result we have to use a photo-injector. In chapter 4 we prove that the silicon tip photocathode are compatible with RF gun requirements by PRIAM modeling and low level measure in a cold model of CANDELA RF gun. Technical department of CERN helped us to prepare this very sensitive experiment. (author)

  10. SWCNT photocathodes sensitised with InP/ZnS core–shell nanocrystals

    OpenAIRE

    Macdonald, Thomas J.; Tune, Daniel D.; Dewi, Melissa R.; Bear, Joseph C.; McNaughter, Paul D.; Mayes, Andrew G.; Skinner, William M.; Parkin, Ivan P.; Shapter, Joseph G.; Nann, Thomas

    2016-01-01

    Increasing the light harvesting efficiency of photocathodes is an integral part of optimising the future efficiencies of solar technologies. In contrast to the more extensively studied photoanode systems, current state-of-the-art photocathodes are less efficient and are commonly replaced with rare and expensive materials such as platinum group metals. The significance of photocathodes is in the development of tandem electrodes, enhancing the performance of existing devices. Carbon nanotubes a...

  11. SWCNT photocathodes sensitised with InP/ZnS core-shell nanocrystals

    OpenAIRE

    Macdonald, T. J.; Tune, D. D.; Dewi, M. R.; Bear, J. C.; McNaughter, P. D.; Mayes, A. G.; Skinner, W. M.; Parkin, I. P.; Shapter, J. G.; Nann, T.

    2016-01-01

    Increasing the light harvesting efficiency of photocathodes is an integral part of optimising the future efficiencies of solar technologies. In contrast to the more extensively studied photoanode systems, current state-of-the-art photocathodes are less efficient and are commonly replaced with rare and expensive materials such as platinum group metals. The significance of photocathodes is in the development of tandem electrodes, enhancing the performance of existing devices. Carbon nanotubes a...

  12. Atomic hydrogen cleaning of GaAs photocathodes

    International Nuclear Information System (INIS)

    Poelker, M.; Price, J.; Sinclair, C.

    1997-01-01

    It is well known that surface contaminants on semiconductors can be removed when samples are exposed to atomic hydrogen. Atomic H reacts with oxides and carbides on the surface, forming compounds that are liberated and subsequently pumped away. Experiments at Jefferson lab with bulk GaAs in a low-voltage ultra-high vacuum H cleaning chamber have resulted in the production of photocathodes with high photoelectron yield (i.e., quantum efficiency) and long lifetime. A small, portable H cleaning apparatus also has been constructed to successfully clean GaAs samples that are later removed from the vacuum apparatus, transported through air and installed in a high-voltage laser-driven spin-polarized electron source. These results indicate that this method is a versatile and robust alternative to conventional wet chemical etching procedures usually employed to clean bulk GaAs

  13. Photocathode non-uniformity contribution to the energy resolution of scintillators

    International Nuclear Information System (INIS)

    Mottaghian, M.; Koohi-Fayegh, R.; Ghal-Eh, N.; Etaati, G. R.

    2010-01-01

    This paper introduces the basics of the light transport simulation in scintillators and the wavelength-dependencies in the process. The non-uniformity measurement of the photocathode surface is undertaken, showing that for the photocathode used in this study the quantum efficiency falls to about 4% of its maximum value, especially in areas far from the centre. The wavelength-and position-dependent quantum efficiency is implemented in the Monte Carlo light transport code, showing that, the contribution of the photocathode non-uniformity to the energy resolution is estimated to be around 18%, when all position-and wavelength-dependencies are included. (authors)

  14. Stable Solar-Blind Ultraviolet III-Nitride Photocathode for Astronomy Applications

    Science.gov (United States)

    Bell, Lloyd

    In this effort, we propose to develop a new type of cesium-free photocathode using III- nitride materials (GaN, AlN, and their alloys) to achieve highly efficient, solar blind, and stable ultraviolet (UV) response. Currently, detectors used in UV instruments utilize a photocathode to convert UV photons into electrons that are subsequently detected by microchannel plate or CCD. The performance of these detectors critically depends on the efficiency and stability of their photocathodes. In particular, photocathode instability is responsible for many of the fabrication difficulties commonly experienced with this class of detectors. In recent years, III-nitride (in particular GaN) photocathodes have been demonstrated with very high quantum efficiency (>50%) in parts of UV spectral range; however, these photocathodes still rely on cesiation for activation. The proposed photocathode structure will achieve activation through methods for band structure engineering such as delta- doping and polarization field engineering. Compared to the current state-of-the-art in flight-ready microchannel plate/Cs2Te sealed tubes, photocathodes based on III-nitride materials will increase the quantum efficiency by nearly an order of magnitude and significantly enhance both fabrication yield and reliability, since they will not require cesium or other highly reactive materials for activation. This performance will enable a next-generation UV spectroscopic and imaging mission that is of high scientific priority for NASA. This photocathode uses near-surface band-structure engineering to create a permanently activated surface, with high efficiency and air-stable UV response. We will combine this III-nitride structure with our unique III-nitride processing technology to optimize the efficiency and uniformity of the photocathode. In addition, through our design, growth, and processing techniques, we will extend the application of these photocathodes into far UV for both semitransparent and

  15. Experimental studies of the charge limit phenomenon in NEA GaAs photocathodes

    International Nuclear Information System (INIS)

    Tang, H.; Alley, R.K.; Aoyagi, H.; Clendenin, J.E.; Frisch, J.C.; Mulhollan, G.A.; Saez, P.J.; Schultz, D.C.; Turner, J.L.

    1994-06-01

    Negative electron affinity GaAs photocathodes have been in continuous use at SLAC for generating polarized electron beams since early 1992. If the quantum efficiency of a GaAs cathode is below a critical value, the maximum photoemitted charge with photons of energies close to the band gap in a 2-ns pulse is found to be limited by the intrinsic properties of the cathode instead of by the space charge limit. We have studied this novel charge limit phenomenon in a variety of GaAs photocathodes of different structures and doping densities. We find that the charge limit is strongly dependent on the cathode's quantum efficiency and the extraction electric field, and to a lesser degree on the excitation laser wavelength. In addition, we show that the temporal behavior of the charge limit depends critically on the doping density

  16. A polarized photoluminescence study of strained layer GaAs photocathodes

    International Nuclear Information System (INIS)

    Mair, R.A.

    1996-07-01

    Photoluminescence measurements have been made on a set of epitaxially grown strained GaAs photocathode structures. The photocathodes are designed to exhibit a strain-induced enhancement of the electron spin polarization obtainable by optical pumping with circularly polarized radiation of near band gap energy. For the case of non-strained GaAs, the degree of spin polarization is limited to 50% by crystal symmetry. Under an appropriate uniaxial compression or tension, however, the valence band structure near the gap minimum is modified such that a spin polarization of 100% is theoretically possible. A total of nine samples with biaxial compressive strains ranging from zero to ∼0.8% are studied. X-ray diffraction analysis, utilizing Bragg reflections, is used to determine the crystal lattice structure of the samples. Luminescence spectra and luminescence circular polarization data are obtained at room temperature, ∼78 K and ∼12 K. The degree of luminescence circular polarization is used as a relative measure of the photo-excited electron spin polarization. The room temperature luminescence circular polarization data is compared with the measured electron spin polarization when the samples are used as electron photo-emitters with a negative electron affinity surface preparation. The luminescence data is also analyzed in conjunction with the crystal structure data with the goal of understanding the strain dependent valence band structure, optical pumping characteristics and spin depolarization mechanisms of the photocathode structures. A simple model is used to describe the luminescence data, obtained for the set of samples. Within the assumptions of the model, the deformation potentials a, b and d for GaAs are determined. The measured values are a = -10.16±.21 eV, b = -2.00±.05 eV and d = -4.87±.29 eV. Good agreement with published values of the deformation potentials provides support for the model used to describe the data

  17. Imaging Hybrid Photon Detectors with a Reflective Photocathode

    CERN Document Server

    Ferenc, D

    2000-01-01

    Modern epitaxially grown photocathodes, like GaAsP, bring a very high inherent quantum efficiency, but are rather expensive due to the complicated manufacturing and mounting process. We argue that such photocathodes could be used in reflective mode, in order to avoid the risky and expensive removal of the epitaxial growth substrate. Besides that the quantum efficiency should increase considerably. In this paper we present results of the development of large imaging Hybrid Photon Detectors (HPDs), particularly designed for such reflective photocathodes.

  18. A Stable, Non-Cesiated III-Nitride Photocathode for Ultraviolet Astronomy Application

    Science.gov (United States)

    Bell, Lloyd

    In this effort, we propose to develop a new type of cesium-free photocathode using III-nitride (III-N) materials (GaN, AlN, and their alloys) and to achieve highly efficient, solar blind, and stable UV response. Currently, detectors used in UV instruments utilize a photocathode to convert UV photons into electrons that are subsequently detected by microchannel plate or CCD. The performance of these detectors critically depends on the efficiency and stability of their photocathodes. In particular, photocathode instability is responsible for many of the fabrication difficulties commonly experienced with this class of detectors. In recent years, III-N (in particular GaN) photocathodes have been demonstrated with very high QE (>50%) in parts of UV spectral range. Moreover, due to the wide bandgaps of III-nitride materials, photocathode response can be tailored to be intrinsically solar-blind. However, these photocathodes still rely on cesiation for activation, necessitating all-vacuum fabrication and sealed-tube operation. The proposed photocathode structure will achieve activation through methods for band structure engineering such as delta-doping and polarization field engineering. Compared to the current state-of-the-art in flight-ready microchannel plate sealed tubes, photocathodes based on III-N materials will yield high QE and significantly enhance both fabrication yield and reliability, since they do not require cesium or other highly reactive materials for activation. This performance will enable a ~4 meter medium class UV spectroscopic and imaging mission that is of high scientific priority for NASA. This work will build on the success of our previous APRA-funded effort. In that work, we demonstrated III-nitride photocathode operation without the use of cesium and stable response with respect to time. These accomplishments represent major improvements to the state-of-the-art for photocathode technologies. In the proposed effort, we will implement III

  19. Jefferson Lab IR demo FEL photocathode quantum efficiency scanner

    CERN Document Server

    Gubeli, J; Grippo, A; Jordan, K; Shinn, M; Siggins, T

    2001-01-01

    Jefferson Laboratory's Free Electron Laser (FEL) incorporates a cesiated gallium arsenide (GaAs) DC photocathode gun as its electron source. By using a set of scanning mirrors, the surface of the GaAs wafer is illuminated with a 543.5nm helium-neon laser. Measuring the current flow across the biased photocathode generates a quantum efficiency (QE) map of the 1-in. diameter wafer surface. The resulting QE map provides a very detailed picture of the efficiency of the wafer surface. By generating a QE map in a matter of minutes, the photocathode scanner has proven to be an exceptional tool in quickly determining sensitivity and availability of the photocathode for operation.

  20. Synchrotron x-ray study of a low roughness and high efficiency K2CsSb photocathode during film growth

    International Nuclear Information System (INIS)

    Xie, Junqi; Demarteau, Marcel; Wagner, Robert; Schubert, Susanne; Gaowei, Mengjia; Attenkofer, Klaus; Walsh, John; Smedley, John; Ben-Zvi, Ilan; Wong, Jared; Feng, Jun; Padmore, Howard; Ruiz-Oses, Miguel; Ding, Zihao; Liang, Xue; Muller, Erik

    2017-01-01

    Reduction of roughness to the nm level is critical of achieving the ultimate performance from photocathodes used in high gradient fields. The thrust of this paper is to explore the evolution of roughness during sequential growth, and to show that deposition of multilayer structures consisting of very thin reacted layers results in an nm level smooth photocathode. Synchrotron x-ray methods were applied to study the multi-step growth process of a high efficiency K 2 CsSb photocathode. A transition point of the Sb film grown on Si was observed at the film thickness of ∼40 Å with the substrate temperature at 100 °C and the growth rate at 0.1 Å s −1 . The final K 2 CsSb photocathode exhibits a thickness of around five times that of the total deposited Sb film regardless of how the Sb film was grown. The film surface roughening process occurs first at the step when K diffuses into the crystalline Sb. The photocathode obtained from the multi-step growth exhibits roughness in an order of magnitude lower than the normal sequential process. X-ray diffraction measurements show that the material goes through two structural changes of the crystalline phase during formation, from crystalline Sb to K 3 Sb and finally to K 2 CsSb. (paper)

  1. Development of a high current 250 kV photocathode dc gun

    International Nuclear Information System (INIS)

    Nishimori, Nobuyuki; Nagai, Ryoji; Sawamura, Masaru; Hajima, Ryoichi

    2016-01-01

    We have developed a high current photocathode dc gun at JAEA for the next generation light sources such as an energy recovery linac and high-repetition rate X-ray free electron laser. The gun is equipped with a multialkali photocathode preparation system. Quantum efficiency of 0.37% at 532 nm was obtained for a Cs_3Sb photocathode. The gun was high voltage conditioned up to 230 kV with a cathode electrode. Beam generation test from the multialkali photocathode will be performed by the end of FY2015. (author)

  2. Surface science analysis of GaAs photocathodes following sustained electron beam delivery

    Directory of Open Access Journals (Sweden)

    V. Shutthanandan

    2012-06-01

    Full Text Available Degradation of the photocathode materials employed in photoinjectors represents a challenge for sustained operation of nuclear physics accelerators and high power free electron lasers (FEL. Photocathode quantum efficiency degradation is due to residual gases in the electron source vacuum system being ionized and accelerated back to the photocathode. These investigations are a first attempt to characterize the nature of the photocathode degradation, and employ multiple surface and bulk analysis techniques to investigate damage mechanisms including sputtering of the Cs-oxidant surface monolayer, other surface chemistry effects, and ion implantation. Surface and bulk analysis studies were conducted on two GaAs photocathodes, which were removed from the JLab FEL DC photoemission gun after delivering electron beam, and two control samples. The analysis techniques include helium ion microscopy, Rutherford backscattering spectrometry (RBS, atomic force microscopy, and secondary ion mass spectrometry (SIMS. In addition, two high-polarization strained superlattice GaAs photocathode samples, one removed from the continuous electron beam accelerator facility (CEBAF photoinjector and one unused, were also analyzed using transmission electron microscopy (TEM and SIMS. It was found that heat cleaning the FEL GaAs wafer introduces surface roughness, which seems to be reduced by prolonged use. The bulk GaAs samples retained a fairly well organized crystalline structure after delivering beam but show evidence of Cs depletion on the surface. Within the precision of the SIMS and RBS measurements, the data showed no indication of hydrogen implantation or lattice damage from ion back bombardment in the bulk GaAs wafers. In contrast, SIMS and TEM measurements of the strained superlattice photocathode show clear crystal damage in the wafer from ion back bombardment.

  3. Field assisted photoemission by silicon photocathodes

    International Nuclear Information System (INIS)

    Aboubacar, A.; Dupont, M.; El Manouni, A.; Querrou, M.; Says, L.P.

    1991-01-01

    Silicon photocathodes with arrays of tips have been prepared using microlithographic techniques. Current emission due to field effect has been measured in the case of heavy and weakly doped boron Silicon. An Argon continuous laser has been used to produce photocurrent. An instantaneous current (600 μA) with a moderate laser power (83 mW), has been produced on weakly doped photocathodes. This current corresponds to an average quantum yield (purely photoelectric) of about 1.7%, and a local current density in the range of a few 10 6 A m -2

  4. Properties of CsI and CsI-TMAE photocathodes

    International Nuclear Information System (INIS)

    Anderson, D.F.; Kwan, S.; Peskov, V.; Hoeneisen, B.

    1992-06-01

    The importance of heating the CsI or CsI-TMAE photocathodes during preparation, as well as the importance of the gas environment on the quantum efficiency is presented. The dependence of the aging characteristics of these photocathodes on the operating temperature, on the presence of gas, and on the charge amplification of the chamber is also discussed. For CsI photocathodes charges in excess of 2x10 14 e - /mm 2 can be collected with little degradation of performance. A timing resolution of 0.55 ns is also achieved for single photoelectrons suggesting a possible time-of-flight detector

  5. Cold electron beams from cryocooled, alkali antimonide photocathodes

    Directory of Open Access Journals (Sweden)

    L. Cultrera

    2015-11-01

    Full Text Available In this paper we report on the generation of cold electron beams using a Cs_{3}Sb photocathode grown by codeposition of Sb and Cs. By cooling the photocathode to 90 K we demonstrate a significant reduction in the mean transverse energy validating the long-standing speculation that the lattice temperature contributes to limiting the mean transverse energy or intrinsic emittance near the photoemission threshold, opening new frontiers in generating ultrabright beams. At 90 K, we achieve a record low intrinsic emittance of 0.2  μm (rms per mm of laser spot diameter from an ultrafast (subpicosecond photocathode with quantum efficiency greater than 7×10^{−5} using a visible laser wavelength of 690 nm.

  6. High-brightness electron beam evolution following laser-based cleaning of a photocathode

    Directory of Open Access Journals (Sweden)

    F. Zhou

    2012-09-01

    Full Text Available Laser-based techniques have been widely used for cleaning metal photocathodes to increase quantum efficiency (QE. However, the impact of laser cleaning on cathode uniformity and thereby on electron beam quality are less understood. We are evaluating whether this technique can be applied to revive photocathodes used for high-brightness electron sources in advanced x-ray free-electron laser (FEL facilities, such as the Linac Coherent Light Source (LCLS at the SLAC National Accelerator Laboratory. The laser-based cleaning was applied to two separate areas of the current LCLS photocathode on July 4 and July 26, 2011, respectively. The QE was increased by 8–10 times upon the laser cleaning. Since the cleaning, routine operation has exhibited a slow evolution of the QE improvement and comparatively rapid improvement of transverse emittance, with a factor of 3 QE enhancement over five months, and a significant emittance improvement over the initial 2–3 weeks following the cleaning. Currently, the QE of the LCLS photocathode is holding constant at about 1.2×10^{-4}, with a normalized injector emittance of about 0.3  μm for a 150-pC bunch charge. With the proper procedures, the laser-cleaning technique appears to be a viable tool to revive the LCLS photocathode. We present observations and analyses for the QE and emittance evolution in time following the laser-based cleaning of the LCLS photocathode, and comparison to the previous studies, the measured thermal emittance versus the QE and comparison to the theoretical model.

  7. Comparative research on the transmission-mode GaAs photocathodes of exponential-doping structures

    International Nuclear Information System (INIS)

    Chen Liang; Qian Yun-Sheng; Zhang Yi-Jun; Chang Ben-Kang

    2012-01-01

    Early research has shown that the varied doping structures of the active layer of GaAs photocathodes have been proven to have a higher quantum efficiency than uniform doping structures. On the basis of our early research on the surface photovoltage of GaAs photocathodes, and comparative research before and after activation of reflection-mode GaAs photocathodes, we further the comparative research on transmission-mode GaAs photocathodes. An exponential doping structure is the typical varied doping structure that can form a uniform electric field in the active layer. By solving the one-dimensional diffusion equation for no equilibrium minority carriers of transmission-mode GaAs photocathodes of the exponential doping structure, we can obtain the equations for the surface photovoltage (SPV) curve before activation and the spectral response curve (SRC) after activation. Through experiments and fitting calculations for the designed material, the body-material parameters can be well fitted by the SPV before activation, and proven by the fitting calculation for SRC after activation. Through the comparative research before and after activation, the average surface escape probability (SEP) can also be well fitted. This comparative research method can measure the body parameters and the value of SEP for the transmission-mode GaAs photocathode more exactly than the early method, which only measures the body parameters by SRC after activation. It can also help us to deeply study and exactly measure the parameters of the varied doping structures for transmission-mode GaAs photocathodes, and optimize the Cs-O activation technique in the future. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  8. A pulsed electron injector using a metal photocathode irradiated by an excimer laser

    International Nuclear Information System (INIS)

    Kauppila, T.J.; Builta, L.A.; Crutcher, J.K.; Elliott, J.C.; Moir, D.C.

    1987-01-01

    The hot cathode of an electron gun is replaced by a metallic photocathode driven by an excimer laser. The current, current density, and emittance of the 500-kV electron beam produced by the photoelectron source are presented. In addition, the temperature of the photocathode is varied to study the possibility of a hybrid source

  9. Polarized Photocathode R&D for Future Linear Collliders

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, F; Brachmann, A.; Maruyama, T.; Sheppard, J.C.; /SLAC

    2009-01-23

    It is a challenge to generate full charge electrons from the electron sources without compromising polarization for the proposed ILC and CLIC. It is essential to advance polarized photocathodes to meet the requirements. SLAC has worldwide unique dedicated test facilities, Cathode Test System and dc-Gun Test Laboratory, to fully characterize polarized photocathodes. Recent systematic measurements on a strained-well InAlGaAs/AlGaAs cathode at the facilities show that 87% polarization and 0.3% QE are achieved. The QE can be increased to {approx}1.0% with atomic hydrogen cleaning. The surface charge limit at a very low current intensity and the clear dependence of the polarization on the surface charge limit are observed for the first time. On-going programs to develop photocathodes for the ILC and CLIC are briefly introduced.

  10. A comparison of surface properties of metallic thin film photocathodes

    CERN Document Server

    Mistry, Sonal; Valizadeh, Reza; Jones, L.B; Middleman, Keith; Hannah, Adrian; Militsyn, B.L; Noakes, Tim

    2017-01-01

    In this work the preparation of metal photocathodes by physical vapour deposition magnetron sputtering has been employed to deposit metallic thin films onto Cu, Mo and Si substrates. The use of metallic cathodes offers several advantages: (i) metal photocathodes present a fast response time and a relative insensitivity to the vacuum environment (ii) metallic thin films when prepared and transferred in vacuum can offer smoother and cleaner emitting surfaces. The photocathodes developed here will ultimately be used in S-band Normal Conducting RF (NCRF) guns such as that used in VELA (Versatile Electron Linear Accelerator) and the proposed CLARA (Compact Linear Accelerator for Research and Applications) Free Electron Laser test facility. The samples grown on Si substrates were used to investigate the morphology and thickness of the film. The samples grown onto Cu and Mo substrates were analysed and tested as photocathodes in a surface characterisation chamber, where X-Ray Photoelectron spectroscopy (XPS) was emp...

  11. Advanced 3D Photocathode Modeling and Simulations Final Report

    International Nuclear Information System (INIS)

    Dimitre A Dimitrov; David L Bruhwiler

    2005-01-01

    High brightness electron beams required by the proposed Next Linear Collider demand strong advances in photocathode electron gun performance. Significant improvement in the production of such beams with rf photocathode electron guns is hampered by the lack high-fidelity simulations. The critical missing piece in existing gun codes is a physics-based, detailed treatment of the very complex and highly nonlinear photoemission process

  12. The effects of electromagnetic space-charge fields in RF photocathode guns

    International Nuclear Information System (INIS)

    Park, C.S.; Hess, M.

    2010-01-01

    In high-brightness rf photocathode guns, the effects of space-charge are important for electron bunches with high bunch charge. In an effort to accurately simulate the effects of these space-charge fields without the presence of numerical grid dispersion, a Green's function based code called IRPSS (Indiana Rf Photocathode Source Simulator) was developed. In this paper, we show the results of numerical simulations of the Argonne Wakefield Accelerator photocathode gun using IRPSS, and compare them with the results of an electrostatic Green's function version of IRPSS.

  13. Characterization of a superconducting Pb photocathode in a superconducting rf photoinjector cavity

    CERN Document Server

    Barday, R; Jankowiak, A; Kamps, T; Knobloch, J; Kugeler, O; Matveenko, A; Neumann, A; Schmeißer, M; Volker, J; Kneisel, P; Nietubyc, R; Schubert S; Smedley J; Sekutowicz, J; Will, I

    2014-01-01

    Photocathodes are a limiting factor for the next generation of ultrahigh brightness photoinjectors. We studied the behavior of a superconducting Pb cathode in the cryogenic environment of a superconducting rf gun cavity to measure the quantum efficiency, its spatial distribution, and the work function. We will also discuss how the cathode surface contaminants modify the performance of the photocathode as well as the gun cavity and we discuss the possibilities to remove these contaminants.

  14. Photocathodes in accelerator applications

    International Nuclear Information System (INIS)

    Fraser, J.S.; Sheffield, R.L.; Gray, E.R.; Giles, P.M.; Springer, R.W.; Loebs, V.A.

    1987-01-01

    Some electron accelerator applications require bursts of short pulses at high microscopic repetition rates and high peak brightness. A photocathode, illuminated by a mode-locked laser, is well suited to filling this need. The intrinsic brightness of a photoemitter beam is high; experiments are under way at Los Alamos to study the brightness of short bunches with high space charge after acceleration. A laser-illuminated Cs 3 Sb photoemitter is located in the first rf cavity of an injector linac. Diagnostics include a pepper-pot emittance analyzer, a magnetic spectrometer, and a streak camera

  15. Dark Current and Multipacting in the Photocathode RF Guns at PITZ

    CERN Document Server

    Hui-Han, Jang; Flöttmann, Klaus; Grabosch, H J; Hartrott, Michael; Krasilnikov, Mikhail; Michelato, Paolo; Miltchev, Velizar; Monaco, Laura; Oppelt, Anne; Petrosyan, Bagrat; Riemann, S; Roensch, Juliane; Schreiber, Siegfried; Sertore, Daniele; Staykov, Lazar; Stephan, Frank

    2005-01-01

    For photocathode rf guns, the amount of dark current depends on the cavity surface and the photocathodes. Smooth conditioning reduces the amount of dark current. Mechanical damages of the cathodes induce high dark current and chemical pollution changes emission properties of the cathode. Multipacting in the gun cavity changes the surface status of the cathodes and sometimes makes the gun operation impossible due to vacuum interlocks. In this paper, dark current and multipacting features of the rf gun are presented including experimental and simulation studies.

  16. Photoemission characteristics of thin GaAs-based heterojunction photocathodes

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Cheng; Zhang, Yijun, E-mail: zhangyijun423@126.com; Qian, Yunsheng [Institute of Electronic Engineering and Optoelectronic Technology, Nanjing University of Science and Technology, Nanjing 210094 (China); Shi, Feng [Science and Technology on Low-Light-Level Night Vision Laboratory, Xi' an 710065 (China); Zou, Jijun [Engineering Research Center of Nuclear Technology Application (East China Institute of Technology), Ministry of Education, Nanchang 330013 (China); Zeng, Yugang [Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033 (China)

    2015-01-14

    To better understand the different photoemission mechanism of thin heterojunction photocathodes, the quantum efficiency models of reflection-mode and transmission-mode GaAs-based heterojunction photocathodes are revised based on one-dimensional continuity equations, wherein photoelectrons generated from both the emission layer and buffer layer are taken into account. By comparison of simulated results between the revised and conventional models, it is found that the electron contribution from the buffer layer to shortwave quantum efficiency is closely related to some factors, such as the thicknesses of emission layer and buffer layer and the interface recombination velocity. Besides, the experimental quantum efficiency data of reflection-mode and transmission-mode AlGaAs/GaAs photocathodes are well fitted to the revised models, which confirm the applicability of the revised quantum efficiency models.

  17. Engineering MoSx/Ti/InP Hybrid Photocathode for Improved Solar Hydrogen Production.

    Science.gov (United States)

    Li, Qiang; Zheng, Maojun; Zhong, Miao; Ma, Liguo; Wang, Faze; Ma, Li; Shen, Wenzhong

    2016-07-19

    Due to its direct band gap of ~1.35 eV, appropriate energy band-edge positions, and low surface-recombination velocity, p-type InP has attracted considerable attention as a promising photocathode material for solar hydrogen generation. However, challenges remain with p-type InP for achieving high and stable photoelectrochemical (PEC) performances. Here, we demonstrate that surface modifications of InP photocathodes with Ti thin layers and amorphous MoSx nanoparticles can remarkably improve their PEC performances. A high photocurrent density with an improved PEC onset potential is obtained. Electrochemical impedance analyses reveal that the largely improved PEC performance of MoSx/Ti/InP is attributed to the reduced charge-transfer resistance and the increased band bending at the MoSx/Ti/InP/electrolyte interface. In addition, the MoSx/Ti/InP photocathodes function stably for PEC water reduction under continuous light illumination over 2 h. Our study demonstrates an effective approach to develop high-PEC-performance InP photocathodes towards stable solar hydrogen production.

  18. Evaluation of the photocathode laser transverse distribution

    Energy Technology Data Exchange (ETDEWEB)

    Saisa-ard, Chaipattana [DESY, Zeuthen (Germany); Chiang Mai Univ., Chiang Mai (Thailand); Krasilnikov, Mikhail; Vashchenko, Grygorii [DESY, Zeuthen (Germany)

    2016-07-01

    Many years experience of electron source developments at the photo injector test facility at DESY in Zeuthen (PITZ) show that the photocathode laser is the one of major tools to produce high brightness electron beams. The transverse distribution of the laser on the photocathode plays a significant role in the high brightness photo injector optimization. However, the imperfections in the laser beam profile according to the deviation from a radially homogeneous profile directly result in transversely distorted charged particle distributions. This includes inhomogeneous core as well as transverse halo which is due to not sharp edges around the core. The laser transverse distribution is measured at PITZ using a virtual cathode:this is a CCD camera located at the position which is optically equivalent to the photocathode position (so called virtual cathode). An algorithm is developed for the evaluation of the experimentally obtained transverse profiles. It fits a flat-top or an inhomogeneous rotational symmetric core with exponentially decaying tails to an experimental distribution. The MATLAB script with implemented algorithm is applied to a set of measured transverse laser distributions. Results of the analysis will be presented.

  19. Photocathode Optimization for a Dynamic Transmission Electron Microscope: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, P; Flom, Z; Heinselman, K; Nguyen, T; Tung, S; Haskell, R; Reed, B W; LaGrange, T

    2011-08-04

    The Dynamic Transmission Electron Microscope (DTEM) team at Harvey Mudd College has been sponsored by LLNL to design and build a test setup for optimizing the performance of the DTEM's electron source. Unlike a traditional TEM, the DTEM achieves much faster exposure times by using photoemission from a photocathode to produce electrons for imaging. The DTEM team's work is motivated by the need to improve the coherence and current density of the electron cloud produced by the electron gun in order to increase the image resolution and contrast achievable by DTEM. The photoemission test setup is nearly complete and the team will soon complete baseline tests of electron gun performance. The photoemission laser and high voltage power supply have been repaired; the optics path for relaying the laser to the photocathode has been finalized, assembled, and aligned; the internal setup of the vacuum chamber has been finalized and mostly implemented; and system control, synchronization, and data acquisition has been implemented in LabVIEW. Immediate future work includes determining a consistent alignment procedure to place the laser waist on the photocathode, and taking baseline performance measurements of the tantalum photocathode. Future research will examine the performance of the electron gun as a function of the photoemission laser profile, the photocathode material, and the geometry and voltages of the accelerating and focusing components in the electron gun. This report presents the team's progress and outlines the work that remains.

  20. Ion Back-Bombardment of GaAs Photocathodes Inside DC High Voltage Electron Guns

    CERN Document Server

    Grames, Joseph M; Brittian, Joshua; Charles, Daniel; Clark, Jim; Hansknecht, John; Lynn Stutzman, Marcy; Poelker, Matthew; Surles-Law, Kenneth E

    2005-01-01

    The primary limitation for sustained high quantum efficiency operation of GaAs photocathodes inside DC high voltage electron guns is ion back-bombardment of the photocathode. This process results from ionization of residual gas within the cathode/anode gap by the extracted electron beam, which is subsequently accelerated backwards to the photocathode. The damage mechanism is believed to be either destruction of the negative electron affinity condition at the surface of the photocathode or damage to the crystal structure by implantation of the bombarding ions. This work characterizes ion formation within the anode/cathode gap for gas species typical of UHV vacuum chambers (i.e., hydrogen, carbon monoxide and methane). Calculations and simulations are performed to determine the ion trajectories and stopping distance within the photocathode material. The results of the simulations are compared with test results obtained using a 100 keV DC high voltage GaAs photoemission gun and beamline at currents up to 10 mA D...

  1. Structured photocathodes for improved high-energy x-ray efficiency in streak cameras

    Energy Technology Data Exchange (ETDEWEB)

    Opachich, Y. P., E-mail: opachiyp@nv.doe.gov; Huffman, E.; Koch, J. A. [National Security Technologies, LLC, Livermore, California 94551 (United States); Bell, P. M.; Bradley, D. K.; Hatch, B.; Landen, O. L.; MacPhee, A. G.; Nagel, S. R. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Chen, N.; Gopal, A.; Udin, S. [Nanoshift LLC, Emeryville, California 94608 (United States); Feng, J. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Hilsabeck, T. J. [General Atomics, San Diego, California 92121 (United States)

    2016-11-15

    We have designed and fabricated a structured streak camera photocathode to provide enhanced efficiency for high energy X-rays (1–12 keV). This gold coated photocathode was tested in a streak camera and compared side by side against a conventional flat thin film photocathode. Results show that the measured electron yield enhancement at energies ranging from 1 to 10 keV scales well with predictions, and that the total enhancement can be more than 3×. The spatial resolution of the streak camera does not show degradation in the structured region. We predict that the temporal resolution of the detector will also not be affected as it is currently dominated by the slit width. This demonstration with Au motivates exploration of comparable enhancements with CsI and may revolutionize X-ray streak camera photocathode design.

  2. Highly stable copper oxide composite as an effective photocathode for water splitting via a facile electrochemical synthesis strategy

    KAUST Repository

    Zhang, Zhonghai; Wang, Peng

    2012-01-01

    focused on n-type metal oxide semiconductors as photoanodes, whereas studies of p-type metal oxide semiconductors as photocathodes where hydrogen is generated are scarce. In this paper, highly efficient and stable copper oxide composite photocathode

  3. Photocathode operation of a thermionic RF gun

    International Nuclear Information System (INIS)

    Thorin, S.; Cutic, N.; Lindau, F.; Werin, S.; Curbis, F.

    2009-01-01

    The thermionic RF gun using a BaO cathode at the MAX-lab linac injector has been successfully commissioned for additional operation as a photocathode gun. By retaining the BaO cathode, lowering the temperature below thermal emission and illuminating it with a UV (263 nm) 9 ps laser pulse a reduced emittance and enhanced emission control has been achieved. Measurements show a normalised emittance of 5.5 mm mrad at 200 pC charge and a maximum quantum efficiency of 1.1x10 -4 . The gun is now routinely switched between storage ring injections in thermionic mode and providing a beam for the MAX-lab test FEL in photocathode mode.

  4. Advanced laser technologies for high-brightness photocathode electron gun

    International Nuclear Information System (INIS)

    Tomizawa, Hiromitsu

    2012-01-01

    A laser-excited photocathode RF gun is one of the most reliable high-brightness electron beam sources for XFELs. Several 3D laser shaping methods have been developed as ideal photocathode illumination sources at SPring-8 since 2001. To suppress the emittance growth caused by nonlinear space-charge forces, the 3D cylindrical UV-pulse was optimized spatially as a flattop and temporally as squarely stacked chirped pulses. This shaping system is a serial combination of a deformable mirror that adaptively shapes the spatial profile with a genetic algorithm and a UV-pulse stacker that consists of four birefringent α-BBO crystal rods for temporal shaping. Using this 3D-shaped pulse, a normalized emittance of 1.4 πmm mrad was obtained in 2006. Utilizing laser's Z-polarization, Schottky-effect-gated photocathode gun was proposed in 2006. The cathode work functions are reduced by a laser-induced Schottky effect. As a result of focusing a radially polarized laser pulse with a hollow lens in vacuum, the Z-field (Z-polarization) is generated at the cathode. (author)

  5. Advanced Laser Technologies for High-brightness Photocathode Electron Gun

    Science.gov (United States)

    Tomizawa, Hiromitsu

    A laser-excited photocathode RF gun is one of the most reliable high-brightness electron beam sources for XFELs. Several 3D laser shaping methods have been developed as ideal photocathode illumination sources at SPring-8 since 2001. To suppress the emittance growth caused by nonlinear space-charge forces, the 3D cylindrical UV-pulse was optimized spatially as a flattop and temporally as squarely stacked chirped pulses. This shaping system is a serial combination of a deformable mirror that adaptively shapes the spatial profile with a genetic algorithm and a UV-pulse stacker that consists of four birefringent α-BBO crystal rods for temporal shaping. Using this 3D-shaped pulse, a normalized emittance of 1.4 π mm mrad was obtained in 2006. Utilizing laser's Z-polarization, Schottky-effect-gated photocathode gun was proposed in 2006. The cathode work functions are reduced by a laser-induced Schottky effect. As a result of focusing a radially polarized laser pulse with a hollow lens in vacuum, the Z-field (Z-polarization) is generated at the cathode.

  6. Experimental studies on the photoemission of gallium arsenide crystals

    International Nuclear Information System (INIS)

    Westermann, M.

    2003-04-01

    In this thesis the study influence of residual gases on the lifetime, the temperature dependence of the quantum yield, and the influence of activation with potassium on both effects for GaAs-photocathodes is described. (HSI)

  7. Amorphous NEA Silicon Photocathodes - A Robust RF Gun Electron Source. Final Report

    International Nuclear Information System (INIS)

    Mulhollan, Gregory A.

    2009-01-01

    Amorphous silicon (a-Si) has been shown to have great promise as a negative electron affinity visible wavelength photocathode suitable for radio frequency (RF) gun systems. The specific operating wavelength can be shifted by growing it as a germanium alloy (a-Si(1-x)Ge(x)) rather than as pure silicon. This class of photoemitters has been shown to possess a high degree of immunity to charged particle flux. Such particle flux can be a significant problem in the operation of other photocathodes in RF gun systems. Its emission characteristics in the form of current per unit area, or current density, and emission angle, or beam spread are well matched for use in RF guns. Photocathodes made of a-Si can be fabricated on a variety of substrates including those most commonly employed in RF gun systems. Such photocathodes can be made for operation in either transmission or reflection mode. By growing them utilizing radio frequency plasma enhanced chemical vapor deposition, the unit cost is quite low, the quality is high and it is straightforward to grow custom size substrates and full or limited regions to confine the electron emission to the desired area. Quality emitters have been fabricated on tantalum, molybdenum, tungsten, titanium, copper, stainless steel, float glass, borosilicate glass and gallium arsenide. In addition to performing well in dedicated test chambers, a-Si photocathodes have been shown to function well in self-contained vacuum tubes. In this employment, they are subjected to a strenuous environment. Successful operation in this configuration provides additional confidence in their application to high energy linac photoinjectors and potentially as part of reliable, low cost photocathode driven RF gun systems that could become ready replacements for the diode and triode guns used on medical accelerators. Their applications in stand-alone vacuum tubes is just beginning to be explored.

  8. High quantum efficiency photocathode simulation for the investigation of novel structured designs

    Energy Technology Data Exchange (ETDEWEB)

    Opachich, Y. P., E-mail: opachiyp@nv.doe.gov; Ross, P. W.; Huffman, E.; Koch, J. A. [National Security Technologies LLC, Livermore, California 94550 (United States); MacPhee, A. G.; Nagel, S. R.; Bell, P. M.; Bradley, D. K.; Landen, O. L. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Hilsabeck, T. J. [General Atomics, San Diego, California 92121 (United States)

    2014-11-15

    A computer model in CST Studio Suite has been developed to evaluate several novel geometrically enhanced photocathode designs. This work was aimed at identifying a structure that would increase the total electron yield by a factor of two or greater in the 1–30 keV range. The modeling software was used to simulate the electric field and generate particle tracking for several potential structures. The final photocathode structure has been tailored to meet a set of detector performance requirements, namely, a spatial resolution of <40 μm and a temporal spread of 1–10 ps. We present the details of the geometrically enhanced photocathode model and resulting static field and electron emission characteristics.

  9. Pulsed laser deposition of yttrium photocathode suitable for use in radio-frequency guns

    Science.gov (United States)

    Lorusso, A.; Trovò, M.; Demidovich, A.; Cinquegrana, P.; Gontad, F.; Broitman, E.; Chiadroni, E.; Perrone, A.

    2017-12-01

    Yttrium (Y) thin film was grown by pulsed laser deposition (PLD) on a copper (Cu) polycrystalline substrate. Ex situ morphological and structural characterisations of the circular Y film of 1.2 µm thickness and 3 mm diameter have shown a very low droplet density on the film surface and a crystalline feature with a preferred orientation along the Y (100) plane. Moreover, Y thin film resulted in being very adherent to the Cu substrate and more scratch resistant than Cu bulk. A twin thin film was deposited also on a Cu backflange of a radio-frequency (RF) gun to test the suitability of the metallic thin film as photocathode. It was observed that the Y-coated photocathode was characterised by a quantum efficiency ( QE) higher than that of the Cu bulk photocathode even if the presence of space charge effects didn't allow deriving the absolute maximum value of QE of Y photocathode.

  10. High Brightness Injectors Based On Photocathode DC Gun

    International Nuclear Information System (INIS)

    B. Yunn

    2001-01-01

    Sample results of new injector design method based on a photocathode dc gun are presented, based on other work analytically proving the validity of the emittance compensation scheme for the case even when beam bunching is involved. We have designed several new injectors appropriate for different bunch charge ranges accordingly. Excellent beam quality produced by these injectors clearly shows that a photocathode dc gun can compete with a rf gun on an equal footing as the source of an electron beam for the bunch charge ranging up to 2 nano Coulomb (nC). This work therefore elevates a dc gun based injector to the preferred choice for many ongoing high brightness accelerator projects considering the proven operational stability and high average power capability of the dc gun

  11. Preliminary Results from a Superconducting Photocathode Sample Cavity

    CERN Document Server

    Kneisel, Peter; Lipski, Andrzej; Sekutowicz, Jacek

    2005-01-01

    Pure niobium has been proposed as a photocathode material and recently a successful test has been conducted with a niobium single cell cavity to extract photo-currents from the surface of this cavity. However, the quantum efficiency of niobium is ~2·10-4, whereas electrodeposited lead has a ~15 times higher quantum efficiency. We have designed and tested a photo-injector niobium cavity, which can be used to insert photo-cathodes made of different materials in the high electric field region of the cavity. Experiments have been conducted with niobium and lead, which show that neither the Q- values of the cavity nor the obtainable surface fields are significantly lowered. This paper reports about the results from these tests.

  12. Characterization of diamond film and bare metal photocathodes as a function of temperature and surface preparation

    Energy Technology Data Exchange (ETDEWEB)

    Shurter, R P; Moir, D C; Devlin, D J [Los Alamos National Laboratory, Los Alamos, NM (United States)

    1997-12-31

    High current photocathodes using bare metal and polycrystalline diamond films illuminated by ultraviolet lasers are being developed at Los Alamos for use in a new generation of linear induction accelerators. These photocathodes must be able to produce multiple 60 ns pulses separated by several to tens of nanoseconds. The vacuum environment in which the photocathodes must operate is {sup 1}0-5 torr. (author). 9 figs., 10 refs.

  13. Theoretical study for heterojunction surface of NEA GaN photocathode dispensed with Cs activation

    Science.gov (United States)

    Xia, Sihao; Liu, Lei; Wang, Honggang; Wang, Meishan; Kong, Yike

    2016-09-01

    For the disadvantages of conventional negative electron affinity (NEA) GaN photocathodes activated by Cs or Cs/O, new-type NEA GaN photocathodes with heterojunction surface dispensed with Cs activation are investigated based on first-principle study with density functional theory. Through the growth of an ultrathin n-type GaN cap layer on p-type GaN emission layer, a p-n heterojunction is formed on the surface. According to the calculation results, it is found that Si atoms tend to replace Ga atoms to result in an n-type doped cap layer which contributes to the decreasing of work function. After the growth of n-type GaN cap layer, the atom structure near the p-type emission layer is changed while that away from the surface has no obvious variations. By analyzing the E-Mulliken charge distribution of emission surface with and without cap layer, it is found that the positive charge of Ga and Mg atoms in the emission layer decrease caused by the cap layer, while the negative charge of N atom increases. The conduction band moves downwards after the growth of cap layer. Si atom produces donor levels around the valence band maximum. The absorption coefficient of GaN emission layer decreases and the reflectivity increases caused by n-type GaN cap layer.

  14. Degradation of Alkali-Based Photocathodes from Exposure to Residual Gases: A First-Principles Study

    International Nuclear Information System (INIS)

    Wang, Gaoxue; Batista, Enrique R.

    2017-01-01

    Photocathodes are a key component in the production of electron beams in systems such as X-ray free-electron lasers and X-ray energy-recovery linacs. Alkali-based materials display high quantum efficiency (QE), however, their QE undergoes degradation faster than metal photocathodes even in the high vacuum conditions where they operate. The high reactivity of alkali-based surfaces points to surface reactions with residual gases as one of the most important factors for the degradation of QE. In order to advance the understanding on the degradation of the QE, we investigated the surface reactivity of common residual gas molecules (e.g., O 2 , CO 2 , CO, H 2 O, N 2 , and H 2 ) on one of the best-known alkali-based photocathode materials, cesium antimonide (Cs 3 Sb), using first-principles calculations based on density functional theory. Furthermore, the reaction sites, adsorption energy, and effect in the local electronic structure upon reaction of these molecules on (001), (110), and (111) surfaces of Cs 3 Sb were computed and analyzed. The adsorption energy of these molecules on Cs3Sb follows the trend of O 2 (-4.5 eV) > CO 2 (-1.9 eV) > H 2 O (-1.0 eV) > CO (-0.8 eV) > N 2 (-0.3 eV) ≈ H 2 (-0.2 eV), which agrees with experimental data on the effect of these gases on the degradation of QE. The interaction strength is determined by the charge transfer from the surfaces to the molecules. The adsorption and dissociation of O containing molecules modify the surface chemistry such as the composition, structure, charge distribution, surface dipole, and work function of Cs 3 Sb, resulting in the degradation of QE with exposure to O 2 , CO 2 , H 2 O, and CO.

  15. Methanol sensor for integration with GaP nanowire photocathode

    Science.gov (United States)

    Novák, J.; Laurenčíková, A.; Hasenohrl, S.; Eliáš, P.; Kováč, J.

    2017-05-01

    We proposed a new type of the methanol concentration sensor that may be integrated directly to the GaP nanostructured photocathode. Necessary attribute for this design is the possibility to make it compatible with p-type of semiconductor. This condition follows from the fact that photocathodes for the CO2 splitting are exclusively prepared from p-type of semiconductors. Design of methanol sensor emanates from this principle. On the GaP substrate is deposited thin Pt supporting layer (100-200 nm thick).This layer is covered by 500 nm thick Nafion membrane that serves as proton filter. On the top of Nafion layer is deposited top Pt contact layer covered by thin nanostructured Pt layer layer with various thickness (0.5 -5 nm). This nanostructured Pt is formed into small islands. It serves as an absorption layer for methanol. Sensor detection properties were estimated from monitoring of I-V characteristics. They were measured in dark and under various methanol concentrations. Dark current values are in order 10-9 A, and this current increases up to order of microamps for methanol of concentration more than 95%.These measurements proved high sensitivity of the GaP compatible sensor structure. Methanol sensors were realized in form of narrow stripe on the side of the photocathode.

  16. Spectral response variation of a negative-electron-affinity photocathode in the preparation process

    International Nuclear Information System (INIS)

    Liu Lei; Du Yujie; Chang Benkang; Yunsheng Qian

    2006-01-01

    In order to research the spectral response variation of a negative electron affinity (NEA) photocathode in the preparation process, we have done two experiments on a transmission-type GaAs photocathode.First, an automatic spectral response recording system is described, which is used to take spectral response curves during the activation procedure of the photocathode. By this system, the spectral response curves of a GaAs:Cs-Ophotocathode measured in situ are presented. Then, after the cathode is sealed with a microchannel plate and a fluorescence screen into the image tube, we measure the spectral response of the tube by another measurement instrument. By way of comparing and analyzing these curves, we can find the typical variation in spectral-responses.The reasons for the variation are discussed. Based on these curves, spectral matching factors of a GaAs cathode for green vegetation and rough concrete are calculated. The visual ranges of night-vision goggles under specific circumstances are estimated. The results show that the spectral response of the NEA photocathode degraded in the sealing process, especially at long wavelengths. The variation has also influenced the whole performance of the intensifier tube

  17. Effects of Surface Nonuniformities on the Mean Transverse Energy from Photocathodes

    Science.gov (United States)

    Karkare, Siddharth; Bazarov, Ivan

    2015-08-01

    The performance of photoinjectors is limited by the lowest value of the mean transverse energy of the electrons obtained from photocathodes. The factors that influence the mean transverse energy are poorly understood. In this paper, we develop models to calculate the effect of spatial work-function variations and subnanometer-scale roughness and surface defects on the mean transverse energy. We show that these can limit the lowest value of mean transverse energy achieved and that atomically perfect surfaces will be required to further reduce the mean transverse energy obtained from photocathodes.

  18. Nonepitaxial Thin-Film InP for Scalable and Efficient Photocathodes.

    Science.gov (United States)

    Hettick, Mark; Zheng, Maxwell; Lin, Yongjing; Sutter-Fella, Carolin M; Ager, Joel W; Javey, Ali

    2015-06-18

    To date, some of the highest performance photocathodes of a photoelectrochemical (PEC) cell have been shown with single-crystalline p-type InP wafers, exhibiting half-cell solar-to-hydrogen conversion efficiencies of over 14%. However, the high cost of single-crystalline InP wafers may present a challenge for future large-scale industrial deployment. Analogous to solar cells, a thin-film approach could address the cost challenges by utilizing the benefits of the InP material while decreasing the use of expensive materials and processes. Here, we demonstrate this approach, using the newly developed thin-film vapor-liquid-solid (TF-VLS) nonepitaxial growth method combined with an atomic-layer deposition protection process to create thin-film InP photocathodes with large grain size and high performance, in the first reported solar device configuration generated by materials grown with this technique. Current-voltage measurements show a photocurrent (29.4 mA/cm(2)) and onset potential (630 mV) approaching single-crystalline wafers and an overall power conversion efficiency of 11.6%, making TF-VLS InP a promising photocathode for scalable and efficient solar hydrogen generation.

  19. Electrostatic X-ray image recording device with mesh-base photocathode photoelectron discriminator means

    International Nuclear Information System (INIS)

    1977-01-01

    An electrostatic X-ray image recording device having a pair of spaced electrodes with a gas-filled gap therebetween, and including discrimination means, having a conductive mesh supporting a photocathodic material, positioned in the gas-filled gap between a first electrode having a layer of ultraviolet-emitting fluorescent material and a second electrode having a plastic sheet adjacent thereto for receiving photoelectrons emitted by the photocathodic material and accelerated to the second electrode by an applied field. The photoconductor-mesh element discriminates against fast electrons, produced by direct impingement of X-rays upon the photocathode to substantially reduce secondary electron production and amplification, thereby increasing both the signal-to-noise and contrast ratios. The electrostatic image formed on the plastic sheet is developed by zerographic techniques after exposure. (Auth.)

  20. Integrated MoSe2 with n+p-Si photocathodes for solar water splitting with high efficiency and stability

    Science.gov (United States)

    Huang, Guanping; Mao, Jie; Fan, Ronglei; Yin, Zhihao; Wu, Xi; Jie, Jiansheng; Kang, Zhenhui; Shen, Mingrong

    2018-01-01

    Many earth-abundant transition metal dichalcogenides (TMDs) have been employed as catalysts for H2 evolution reaction (HER); however, their impactful integration onto photocathodes for photoelectrochemical (PEC) HER is less developed. In this study, we directly sputtered a MoSe2 catalyst onto an n+p-Si photocathode for efficient and stable PEC-HER. An onset potential of 0.4 V vs. RHE, a saturated photocurrent of 29.3 mA/cm2, a fill factor of 0.32, and an energy conversion efficiency of 3.8% were obtained under 100 mA/cm2 Xe lamp illumination. Such superior PEC properties were ascribed to the nearly vertically standing two dimensional MoSe2 rough surface layer and the sharp interface between Si and MoSe2 with small charge transfer resistance. The balance between the reflectivity of the electrode surface and the absorptivity of MoSe2 was also discussed. In addition, the MoSe2 layer can protect the n+p-Si photocathode with a 120 h stability due to its initial growth on Si with high flatness and compactness. This study provides a path to the effective and scalable growth of TMDs onto the Si photocathode aiming for high efficiency and stability.

  1. Quantum efficiency and thermal emittance of metal photocathodes

    Directory of Open Access Journals (Sweden)

    David H. Dowell

    2009-07-01

    Full Text Available Modern electron beams have demonstrated the brilliance needed to drive free electron lasers at x-ray wavelengths with major advances occurring since the invention of the photocathode gun and the realization of emittance compensation. These state-of-the-art electron beams are now becoming limited by the intrinsic thermal emittance of the cathode. In both dc and rf photocathode guns details of the cathode emission physics strongly influence the quantum efficiency and the thermal emittance. Therefore improving cathode performance is essential to increasing the brightness of beams. It is especially important to understand the fundamentals of cathode quantum efficiency and thermal emittance. This paper investigates the relationship between the quantum efficiency and the thermal emittance for metal cathodes using the Fermi-Dirac model for the electron distribution. We use a consistent theory to derive the quantum efficiency and thermal emittance, and compare our results to those of others.

  2. Structural transformation of CsI thin film photocathodes under exposure to air and UV irradiation

    CERN Document Server

    Tremsin, A S; Siegmund, O H W

    2000-01-01

    Transmission electron microscopy has been employed to study the structure of polycrystalline CsI thin films and its transformation under exposure to humid air and UV irradiation. The catastrophic degradation of CsI thin film photocathode performance is shown to be associated with the film dissolving followed by its re-crystallization. This results in the formation of large lumps of CsI crystal on the substrate surface, so that the film becomes discontinuous and its performance as a photocathode is permanently degraded. No change in the surface morphology and the film crystalline structure was observed after the samples were UV irradiated.

  3. High current polarized electron source

    Science.gov (United States)

    Suleiman, R.; Adderley, P.; Grames, J.; Hansknecht, J.; Poelker, M.; Stutzman, M.

    2018-05-01

    Jefferson Lab operates two DC high voltage GaAs photoguns with compact inverted insulators. One photogun provides the polarized electron beam at the Continuous Electron Beam Accelerator Facility (CEBAF) up to 200 µA. The other gun is used for high average current photocathode lifetime studies at a dedicated test facility up to 4 mA of polarized beam and 10 mA of un-polarized beam. GaAs-based photoguns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed facilities that must operate in excess of tens of mA of polarized average current. This contribution describes techniques to maintain good vacuum while delivering high beam currents, and techniques that minimize damage due to ion bombardment, the dominant mechanism that reduces photocathode yield. Advantages of higher DC voltage include reduced space-charge emittance growth and the potential for better photocathode lifetime. Highlights of R&D to improve the performance of polarized electron sources and prolong the lifetime of strained-superlattice GaAs are presented.

  4. Temporal resolution limit estimation of x-ray streak cameras using a CsI photocathode

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiang; Gu, Li; Zong, Fangke; Zhang, Jingjin; Yang, Qinlao, E-mail: qlyang@szu.edu.cn [Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Institute of Optoelectronics, Shenzhen University, Shenzhen 518060 (China)

    2015-08-28

    A Monte Carlo model is developed and implemented to calculate the characteristics of x-ray induced secondary electron (SE) emission from a CsI photocathode used in an x-ray streak camera. Time distributions of emitted SEs are investigated with an incident x-ray energy range from 1 to 30 keV and a CsI thickness range from 100 to 1000 nm. Simulation results indicate that SE time distribution curves have little dependence on the incident x-ray energy and CsI thickness. The calculated time dispersion within the CsI photocathode is about 70 fs, which should be the temporal resolution limit of x-ray streak cameras that use CsI as the photocathode material.

  5. Sources of Emittance in RF Photocathode Injectors

    Energy Technology Data Exchange (ETDEWEB)

    Dowell, David [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-12-11

    Advances in electron beam technology have been central to creating the current generation of x-ray free electron lasers and ultra-fast electron microscopes. These once exotic devices have become essential tools for basic research and applied science. One important beam technology for both is the electron source which, for many of these instruments, is the photocathode RF gun. The invention of the photocathode gun and the concepts of emittance compensation and beam matching in the presence of space charge and RF forces have made these high-quality beams possible. Achieving even brighter beams requires a taking a finer resolution view of the electron dynamics near the cathode during photoemission and the initial acceleration of the beam. In addition, the high brightness beam is more sensitive to degradation by the optical aberrations of the gun’s RF and magnetic lenses. This paper discusses these topics including the beam properties due to fundamental photoemission physics, space charge effects close to the cathode, and optical distortions introduced by the RF and solenoid fields. Analytic relations for these phenomena are derived and compared with numerical simulations.

  6. Performance of photocathode rf gun electron accelerators

    International Nuclear Information System (INIS)

    Ben-Zvi, I.

    1993-01-01

    In Photo-Injectors (PI) electron guns, electrons are emitted from a photocathode by a short laser pulse and then accelerated by intense rf fields in a resonant cavity. The best known advantage of this technique is the high peak current with a good emittance (high brightness). This is important for short wavelength Free-Electron Lasers and linear colliders. PIs are in operation in many electron accelerator facilities and a large number of new guns are under construction. Some applications have emerged, providing, for example, very high pulse charges. PIs have been operated over a wide range of frequencies, from 144 to 3000 MHz (a 17 GHz gun is being developed). An exciting new possibility is the development of superconducting PIs. A significant body of experimental and theoretical work exists by now, indicating the criticality of the accelerator elements that follow the gun for the preservation of the PI's performance as well as possible avenues of improvements in brightness. Considerable research is being done on the laser and photocathode material of the PI, and improvement is expected in this area

  7. Photocathodes for High Repetition Rate Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi, Ilan [Stony Brook Univ., NY (United States). Dept. of Physics and Astronomy. Center for Accelerator Science and Education

    2014-04-20

    This proposal brought together teams at Brookhaven National Laboratory (BNL), Lawrence Berkeley National Laboratory (LBNL) and Stony Brook University (SBU) to study photocathodes for high repetition rate light sources such as Free Electron Lasers (FEL) and Energy Recovery Linacs (ERL). Below details the Principal Investigators and contact information. Each PI submits separately for a budget through his corresponding institute. The work done under this grant comprises a comprehensive program on critical aspects of the production of the electron beams needed for future user facilities. Our program pioneered in situ and in operando diagnostics for alkali antimonide growth. The focus is on development of photocathodes for high repetition rate Free Electron Lasers (FELs) and Energy Recovery Linacs (ERLs), including testing SRF photoguns, both normal-­conducting and superconducting. Teams from BNL, LBNL and Stony Brook University (SBU) led this research, and coordinated their work over a range of topics. The work leveraged a robust infrastructure of existing facilities and the support was used for carrying out the research at these facilities. The program concentrated in three areas: a) Physics and chemistry of alkali-­antimonide cathodes (BNL – LBNL) b) Development and testing of a diamond amplifier for photocathodes (SBU -­ BNL) c) Tests of both cathodes in superconducting RF photoguns (SBU) and copper RF photoguns (LBNL) Our work made extensive use of synchrotron radiation materials science techniques, such as powder-­ and single-­crystal diffraction, x-­ray fluorescence, EXAFS and variable energy XPS. BNL and LBNL have many complementary facilities at the two light sources associated with these laboratories (NSLS and ALS, respectively); use of these will be a major thrust of our program and bring our understanding of these complex materials to a new level. In addition, CHESS at Cornell will be used to continue seamlessly throughout the NSLS dark period and

  8. Tight comparison of Mg and Y thin film photocathodes obtained by the pulsed laser deposition technique

    Energy Technology Data Exchange (ETDEWEB)

    Lorusso, A. [Dipartimento di Matematica e Fisica “E. De Giorgi”, Università del Salento and Istituto Nazionale di Fisica Nucleare, 73100 Lecce (Italy); Gontad, F., E-mail: francisco.gontad@le.infn.it [Dipartimento di Matematica e Fisica “E. De Giorgi”, Università del Salento and Istituto Nazionale di Fisica Nucleare, 73100 Lecce (Italy); Solombrino, L. [Dipartimento di Matematica e Fisica “E. De Giorgi”, Università del Salento and Istituto Nazionale di Fisica Nucleare, 73100 Lecce (Italy); Chiadroni, E. [Laboratori Nazionali di Frascati, Istituto Nazionale di Fisica Nucleare, 00044 Frascati (Italy); Broitman, E. [Department of Physics, Chemistry and Biology (IFM), Linköping University, SE-58183 Linköping (Sweden); Perrone, A. [Dipartimento di Matematica e Fisica “E. De Giorgi”, Università del Salento and Istituto Nazionale di Fisica Nucleare, 73100 Lecce (Italy)

    2016-11-11

    In this work Magnesium (Mg) and Yttrium (Y) thin films have been deposited on Copper (Cu) polycrystalline substrates by the pulsed laser ablation technique for photocathode application. Such metallic materials are studied for their interesting photoemission properties and are proposed as a good alternative to the Cu photocathode, which is generally used in radio-frequency guns. Mg and Y films were uniform with no substantial differences in morphology; a polycrystalline structure was found for both of them. Photoemission measurements of such cathodes based on thin films were performed, revealing a quantum efficiency higher than Cu bulk. Photoemission theory according to the three-step model of Spicer is invoked to explain the superior photoemission performance of Mg with respect to Y. - Highlights: • Mg and Y thin film photocathodes were successfully prepared by pulsed laser deposition. • Mg quantum efficiency is higher than Y, despite its higher work function. • The three-step model of Spicer justify the difference in quantum efficiency.

  9. S-11 and S-20 photocathode research activity. Rev. 1

    International Nuclear Information System (INIS)

    Gex, F.; Huen, T.; Kalibjian, R.

    1984-01-01

    The S-1 semi-transparent photocathode is the only one that can be used to study the 1.06 μm neodynium laser pulses of less than 10 ps duration. We first reviewed the recent results obtained at the Paris Observatory (research sponsored by the CEA), and then we tried to determine the role of the main constituents and their contributions in photoemission

  10. Femtosecond response time measurements of a Cs2Te photocathode

    Science.gov (United States)

    Aryshev, A.; Shevelev, M.; Honda, Y.; Terunuma, N.; Urakawa, J.

    2017-07-01

    Success in design and construction of a compact, high-brightness accelerator system is strongly related to the production of ultra-short electron beams. Recently, the approach to generate short electron bunches or pre-bunched beams in RF guns directly illuminating a high quantum efficiency semiconductor photocathode with femtosecond laser pulses has become attractive. The measurements of the photocathode response time in this case are essential. With an approach of the interferometer-type pulse splitter deep integration into a commercial Ti:Sa laser system used for RF guns, it has become possible to generate pre-bunched electron beams and obtain continuously variable electron bunch separation. In combination with a well-known zero-phasing technique, it allows us to estimate the response time of the most commonly used Cs2Te photocathode. It was demonstrated that the peak-to-peak rms time response of Cs2Te is of the order of 370 fs, and thereby, it is possible to generate and control a THz sequence of relativistic electron bunches by a conventional S-band RF gun. This result can also be applied for investigation of other cathode materials and electron beam temporal shaping and further opens a possibility to construct wide-range tunable, table-top THz free electron laser.

  11. Double-layered NiO photocathodes for p-type DSSCs with record IPCE

    Energy Technology Data Exchange (ETDEWEB)

    Li, Lin; Qin, Peng; Gorlov, Mikhail [Center of Molecular Devices School of Chemical Science and Engineering, Royal Institute of Technology (KTH), Stockholm (Sweden); Gibson, Elizabeth A.; Boschloo, Gerrit [Department of Physical and Analytical Chemistry, Uppsala University (Sweden); Hagfeldt, Anders [Center of Molecular Devices School of Chemical Science and Engineering, Royal Institute of Technology (KTH), Stockholm (Sweden); Department of Physical and Analytical Chemistry, Uppsala University (Sweden); DUT-KTH Joint Education and Research Center of Molecular Devices, State Key Laboratory of Fine Chemicals, Dalian University of Technology (DUT), Dalian (China); Sun, Licheng [Center of Molecular Devices School of Chemical Science and Engineering, Royal Institute of Technology (KTH), Stockholm (Sweden); DUT-KTH Joint Education and Research Center of Molecular Devices, State Key Laboratory of Fine Chemicals, Dalian University of Technology (DUT), Dalian (China)

    2010-04-18

    A way to achieve a high-efficiency dye-sensitized solar cell is to combine an n-type TiO{sub 2}-based photoanode with a p-type photocathode in a tandem configuration. The development of an efficient photocathode is, at present, the key target. We have optimized the NiO, I{sub 3}{sup -}/I{sup -} p-DSSC system to obtain record photocurrent, giving 64% incident photon-to-current conversion efficiency (IPCE) and 5.48 mAcm{sup -2} J{sub SC}. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  12. Automated installation for several photomultiplier photocathode activation by means of one vacuum facility

    International Nuclear Information System (INIS)

    Beschastnov, P.M.; Peryshkin, A.I.; Pyata, E.Eh.; Usov, Yu.V.

    1989-01-01

    An automated installation for simultaneous activation of up to four photocathodes of several photomultipliers by means of one vacuum station with the common furnace is described. Production technology of producing multialkaline photocathode makes up the basis for creating automated technology. The installation is produced on the base of the R110B industrial station and the Electronica-60 microcomputer. Software written in FORTRAN providing for control over all process stages is developed. 6 refs.; 2 figs

  13. Photocathodes inside superconducting cavities. Studies on the feasibility of a superconducting photoelectron source of high brightness. External report

    International Nuclear Information System (INIS)

    Michalke, A.

    1992-01-01

    We have done studies and experiments to explore the feasibility of a photoemission RF gun with a superconducting accelerator cavity. This concept promises to provide an electron beam of high brightness in continuous operation. It is thus of strong interest for a free-electron-laser or a linear collider based on a superconducting accelerator. In a first step we studied possible technical solutions for its components, especially the material of the photocathode and the geometrical shape of the cavity. Based on these considerations, we developed the complete design for a prototype electron source. The cathode material was chosen to be alkali antimonide. In spite of its sensitivity, it seems to be the best choice for a gun with high average current due to its high quantum efficiency. The cavity shape was at first a reentrant-type single cell of 500 MHz. It is now replaced by a more regular two-and-half cell shape, an independent half cell added for emittance correction. Its beam dynamics properties are investigated by numerical simulations; we estimated a beam brightness of about 5x10 11 A/(m.rad) 2 . But the mutual interactions between alkali antimonide photocathode and superconducting cavity must be investigated experimentally, because they are completely unkown. (orig.)

  14. The Quantum Efficiency and Thermal Emittance of Metal Photocathodes

    International Nuclear Information System (INIS)

    Dowell, D.

    2009-01-01

    Modern electron beams have demonstrated the brilliance needed to drive free electron lasers at x-ray wavelengths, with the principle improvements occurring since the invention of the photocathode gun. The state-of-the-art normalized emittance electron beams are now becoming limited by the thermal emittance of the cathode. In both DC and RF photocathode guns, details of the cathode emission physics strongly influence the quantum efficiency and the thermal emittance. Therefore improving cathode performance is essential to increasing the brightness of beams. It is especially important to understand the fundamentals of cathode quantum efficiency and thermal emittance. This paper investigates the relationship between the quantum efficiency and the thermal emittance of metal cathodes using the Fermi-Dirac model for the electron distribution. We derive the thermal emittance and its relationship to the quantum efficiency, and compare our results to those of others

  15. Technology to Establish a Factory for High QE Alkali Antimonide Photocathodes

    Energy Technology Data Exchange (ETDEWEB)

    Schultheiss, Thomas [Advanced Energy Systems, Inc., Medford, NY (United States)

    2015-11-16

    Intense electron beams are key to a large number of scientific endeavors, including electron cooling of hadron beams, electron-positron colliders, secondary-particle beams such as photons and positrons, sub-picosecond ultrafast electron diffraction (UED), and new high gradient accelerators that use electron-driven plasmas. The last decade has seen a considerable interest in pursuit and realization of novel light sources such as Free Electron Lasers [1] and Energy Recovery Linacs [2] that promise to deliver unprecedented quality x-ray beams. Many applications for high-intensity electron beams have arisen in recent years in high-energy physics, nuclear physics and energy sciences, such as recent designs for an electron-hadron collider at CERN (LHeC) [3], and beam coolers for hadron beams at LHC and eRHIC [4,5]. Photoinjectors are used at the majority of high-brightness electron linacs today, due to their efficiency, timing structure flexibility and ability to produce high power, high brightness beams. The performance of light source machines is strongly related to the brightness of the electron beam used for generating the x-rays. The brightness of the electron beam itself is mainly limited by the physical processes by which electrons are generated. For laser based photoemission sources this limit is ultimately related to the properties of photocathodes [6]. Most facilities are required to expend significant manpower and money to achieve a workable, albeit often non-ideal, compromise photocathode solution. If entirely fabricated in-house, the photocathode growth process itself is laborious and not always reproducible: it involves the human element while requiring close adherence to recipes and extremely strict control of deposition parameters. Lack of growth reliability and as a consequence, slow adoption of viable photoemitter types, can be partly attributed to the absence of any centralized facility or commercial entity to routinely provide high peak current

  16. An in-situ photocathode loading system for the SLC Polarized Electron Gun

    International Nuclear Information System (INIS)

    Kirby, R.E.; Collet, G.J.; Skarpaas, K.

    1992-12-01

    An ultra-high vacuum loadlock system capable of operating at high voltage has been added to the SLC Polarized Electron Gun. The unit incorporates facilities for heat cleaning, activating and measuring the quantum efficiency of photocathodes. A tray of up to four photocathodes can be exchanged without bringing the activation unit or gun up to atmosphere. Low voltage quantum efficiencies of 20% have been obtained for bulk GaAs at 633 nm and 6% for a 0.3 micron GaAs layer at 755 nm. Results for other cathodes as well as operational characteristics are discussed

  17. Polarized Light Sources for photocathode electron guns at SLAC

    International Nuclear Information System (INIS)

    Woods, M.; Frisch, J.; Witte, K.; Zolotorev, M.

    1992-12-01

    We describe current and future Polarized Light Sources at SLAC for use with photocathode electron guns to produce polarized electron beams. The SLAC experiments SLD and E142 are considered, and are used to define the required parameters for the Polarized Light Sources

  18. Progress on Lead Photocathodes for Superconducting Injectors

    CERN Document Server

    Smedley, John; Langner, Jerzy; Lefferts, Richard; Lipski, Andrzej; Rao, Triveni; Sekutowicz, Jacek; Strzyzewski, P

    2005-01-01

    We present the results of our investigation of bulk, electroplated and vacuum deposited lead as suitable photocathode materials for superconducting RF injectors. The quantum efficiency of each sample is presented as a function of the wavelength of the incident light, from 310 nm to 190 nm. Quantum efficiencies of 0.3% have been obtained. Production of a niobium cavity with a lead-plated cathode is underway.

  19. {Ni4O4} Cluster Complex to Enhance the Reductive Photocurrent Response on Silicon Nanowire Photocathodes

    Directory of Open Access Journals (Sweden)

    Yatin J. Mange

    2017-02-01

    Full Text Available Metal organic {Ni4O4} clusters, known oxidation catalysts, have been shown to provide a valuable route in increasing the photocurrent response on silicon nanowire (SiNW photocathodes. {Ni4O4} clusters have been paired with SiNWs to form a new photocathode composite for water splitting. Under AM1.5 conditions, the combination of {Ni4O4} clusters with SiNWs gave a current density of −16 mA/cm2, which corresponds to an increase in current density of 60% when compared to bare SiNWs. The composite electrode was fully characterised and shown to be an efficient and stable photocathode for water splitting.

  20. Beam Dynamics Simulation of Photocathode RF Electron Gun at the PBP-CMU Linac Laboratory

    Science.gov (United States)

    Buakor, K.; Rimjaem, S.

    2017-09-01

    Photocathode radio-frequency (RF) electron guns are widely used at many particle accelerator laboratories due to high quality of produced electron beams. By using a short-pulse laser to induce the photoemission process, the electrons are emitted with low energy spread. Moreover, the photocathode RF guns are not suffered from the electron back bombardment effect, which can cause the limited electron current and accelerated energy. In this research, we aim to develop the photocathode RF gun for the linac-based THz radiation source. Its design is based on the existing gun at the PBP-CMU Linac Laboratory. The gun consists of a one and a half cell S-band standing-wave RF cavities with a maximum electric field of about 60 MV/m at the centre of the full cell. We study the beam dynamics of electrons traveling through the electromagnetic field inside the RF gun by using the particle tracking program ASTRA. The laser properties i.e. transverse size and injecting phase are optimized to obtain low transverse emittance. In addition, the solenoid magnet is applied for beam focusing and emittance compensation. The proper solenoid magnetic field is then investigated to find the optimum value for proper emittance conservation condition.

  1. Integration of Transients in Axisymmetrical Cavities for Accelerators: Formulation and applications to BNL Photocathode Gun

    International Nuclear Information System (INIS)

    Parsa, Z.; Serafini, L.

    1992-04-01

    This note provides a sketch of the formalism used for the Integration of Transients in Axisymmetrical Cavities for Accelerators, (ITACA). Application to study the BNL Photocathode Gun via the code ITACA is also included

  2. Thermal Emittance Measurement of the Cs2Te Photocathode in FZD Superconducting RF

    CERN Document Server

    Xiang, R; Michel, P; Murcek, P; Teichert, J

    2010-01-01

    The thermal emittance of the photocathode is an interesting physical property for the photoinjector, because it decides the minimum emittance the photoinjector can finally achieve. In this paper we will report the latest results of the thermal emittance of the Cs2Te photocathode in FZD Superconducting RF gun. The measurement is performed with solenoid scan method with very low bunch charge and relative large laser spot on cathode, in order to reduce the space charge effect as much as possible, and meanwhile to eliminate the wake fields and the effect from beam halos.

  3. High polarization photocathode R ampersand D at SLAC

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Garwin, E.L.; Prepost, R.; Zaplac, G.H.

    1993-01-01

    This paper describes recent progress on the development of high polarization photocathodes for polarized electron sources. A strained InGaAs cathode has achieved a maximum electron-spin polarization of 71% and has demonstrated the strain enhancement of polarization for the first time. Strained GaAs cathodes have yielded polarizations as high as 90% with much higher quantum efficiency

  4. Single-side electron multipacting at the photocathode in rf guns

    Directory of Open Access Journals (Sweden)

    Jang-Hui Han

    2008-01-01

    Full Text Available Multiple electron impacting (multipacting can take place in rf fields when the rf components are composed of materials with a secondary electron yield greater than one. In rf gun cavities, multipacting may change the properties of the vacuum components or even damage them. First systematic measurements of the multipacting occurring in a photocathode rf gun were made at the Fermilab/NICADD Photoinjector Laboratory in 2000. The multipacting properties were found to depend on the cathode material and the solenoid field configuration. In this study, we measure the multipacting properties in more detail and model the secondary electron generation for numerical simulation. Measurements and simulations for the photoinjectors at Fermilab and DESY are compared. The multipacting takes place at the photocathode in rf guns and is categorized as single-side multipacting. In a low rf field, the electrons emitted from the cathode area do not leave the gun cavity within one rf cycle and have an opportunity to travel back and hit the cathode. The solenoid field distribution in the vicinity of the cathode changes the probability of electron bombardment of the cathode and makes a major contribution to the multipacting behavior.

  5. Lasertron, a pulsed RF-source using laser triggered photocathode

    International Nuclear Information System (INIS)

    Yoshioka, Masakazu.

    1988-12-01

    A new pulsed RF-source, 'Lasertron', are being developed as a possible RF-power source for future electron-positron linear colliders. In a series of systematic study, a prototype lasertron has been fabricated and tested. A peak power of 80 kW is attained at 2.856 GHz RF-frequency in 1-μs time duration. This paper describes the experimental results of the lasertron including the developments of the photocathode and the laser system. Test results are compared with the analysis of beam dynamics in the lasertron. (author)

  6. Equivalent Method of Solving Quantum Efficiency of Reflection-Mode Exponential Doping GaAs Photocathode

    International Nuclear Information System (INIS)

    Jun, Niu; Zhi, Yang; Ben-Kang, Chang

    2009-01-01

    The mathematical expression of the electron diffusion and drift length L DE of exponential doping photocathode is deduced. In the quantum efficiency equation of the reffection-mode uniform doping cathode, substituting L DE for L D , the equivalent quantum efficiency equation of the reffection-mode exponential doping cathode is obtained. By using the equivalent equation, theoretical simulation and experimental analysis shows that the equivalent index formula and formula-doped cathode quantum efficiency results in line. The equivalent equation avoids complicated calculation, thereby simplifies the process of solving the quantum efficiency of exponential doping photocathode

  7. Graphene-based copper oxide thin film nanostructures as high-efficiency photocathode for p-type dye-sensitized solar cells

    Science.gov (United States)

    Kilic, Bayram; Turkdogan, Sunay; Astam, Aykut; Baran, Sümeyra Seniha; Asgin, Mansur; Cebeci, Hulya; Urk, Deniz

    2017-10-01

    Graphene-based p-type dye-sensitized solar cells (p-DSSCs) have been proposed and fabricated using copper oxide urchin-like nanostructures (COUN) as photocathode with an FeS2 counter electrode (CE). COUN composed of Cu2O core sphere and CuO shell nanorods with overall diameters of 2 to 4 μm were grown by a simple hydrothermal method with self-assemble nucleation. It was figured out that the formation of copper oxide core/shell structures could be adjusted by an ammonia additive leading to pH change of the precursor solution. In addition to a photocathode, we also demonstrated FeS2 thin films as an efficient CE material alternative to the conventional Pt CEs in DSSCs. FeS2 nanostructures, with diameters of 50 to 80 nm, were synthesized by a similar hydrothermal approach. FeS2 nanostructures are demonstrated to be an outstanding CE material in p-DSSCs. We report graphene/COUN as photocathode and Pt/FeS2 as CE in p-DSSCs, and results show that the synergetic combination of electrodes in each side (increased interconnectivity between COUN and graphene layer, high surface area, and high catalytic activity of FeS2) increased the power conversion efficiency from 1.56% to 3.14%. The excellent performances of COUN and FeS2 thin film in working and CEs, respectively, make them unique choices among the various photocathode and CE materials studied.

  8. Hierarchical Cu2O foam/g-C3N4 photocathode for photoelectrochemical hydrogen production

    Science.gov (United States)

    Ma, Xinzhou; Zhang, Jingtao; Wang, Biao; Li, Qiuguo; Chu, Sheng

    2018-01-01

    Solar photoelectrochemical (PEC) hydrogen production is a promising way for solving energy and environment problems. Earth-abundant Cu2O is a potential light absorber for PEC hydrogen production. In this article, hierarchical porous Cu2O foams are prepared by thermal oxidation of the electrochemically deposited Cu foams. PEC performances of the Cu2O foams are systematically studied and discussed. Benefiting from their higher light harvesting and more efficient charge separation, the Cu2O foams demonstrate significantly enhanced photocurrents and photostability compared to their film counterparts. Moreover, by integrating g-C3N4, hierarchical Cu2O foam/g-C3N4 composites are prepared with further improved photocurrent and photostability, appearing to be potential photocathodes for solar PEC hydrogen production. This study may provide a new and useful insight for the development of Cu2O-based photocathodes for PEC hydrogen production.

  9. Picosecond electron bunches from GaAs/GaAsP strained superlattice photocathode

    International Nuclear Information System (INIS)

    Jin, Xiuguang; Matsuba, Shunya; Honda, Yosuke; Miyajima, Tsukasa; Yamamoto, Masahiro; Utiyama, Takashi; Takeda, Yoshikazu

    2013-01-01

    GaAs/GaAsP strained superlattices are excellent candidates for use as spin-polarized electron sources. In the present study, picosecond electron bunches were successfully generated from such a superlattice photocathode. However, electron transport in the superlattice was much slower than in bulk GaAs. Transmission electron microscopy observations revealed that a small amount of variations in the uniformity of the layers was present in the superlattice. These variations lead to fluctuations in the superlattice mini-band structure and can affect electron transport. Thus, it is expected that if the periodicity of the superlattice can be improved, much faster electron bunches can be produced. - Highlights: • GaAs/GaAsP strained superlattices are excellent candidates for spin-polarized electron beam. • Pulse spin-polarized electron beam is required for investigating the magnetic domain change. • Picosecond electron bunches were achieved from GaAs/GaAsP superlattice photocathode. • TEM observation revealed a small disorder of superlattice layers. • Improvement of superlattice periodicity can achieve much faster electron bunches

  10. A novel scaling law relating the geometrical dimensions of a photocathode radio frequency gun to its radio frequency properties

    Science.gov (United States)

    Lal, Shankar; Pant, K. K.; Krishnagopal, S.

    2011-12-01

    Developing a photocathode RF gun with the desired RF properties of the π-mode, such as field balance (eb) ˜1, resonant frequency fπ = 2856 MHz, and waveguide-to-cavity coupling coefficient βπ ˜1, requires precise tuning of the resonant frequencies of the independent full- and half-cells (ff and fh), and of the waveguide-to-full-cell coupling coefficient (βf). While contemporary electromagnetic codes and precision machining capability have made it possible to design and tune independent cells of a photocathode RF gun for desired RF properties, thereby eliminating the need for tuning, access to such computational resources and quality of machining is not very widespread. Therefore, many such structures require tuning after machining by employing conventional tuning techniques that are iterative in nature. Any procedure that improves understanding of the tuning process and consequently reduces the number of iterations and the associated risks in tuning a photocathode gun would, therefore, be useful. In this paper, we discuss a method devised by us to tune a photocathode RF gun for desired RF properties under operating conditions. We develop and employ a simple scaling law that accounts for inter-dependence between frequency of independent cells and waveguide-to-cavity coupling coefficient, and the effect of brazing clearance for joining of the two cells. The method has been employed to successfully develop multiple 1.6 cell BNL/SLAC/UCLA type S-band photocathode RF guns with the desired RF properties, without the need to tune them by a tiresome cut-and-measure process. Our analysis also provides a physical insight into how the geometrical dimensions affect the RF properties of the photo-cathode RF gun.

  11. Enhanced photoelectrochemical water splitting by oxides heterojunction photocathode coupled with Ag.

    Science.gov (United States)

    Lu, Xue; Liu, Zhifeng

    2017-08-14

    A novel one-dimensional Co 3 O 4 /CuO/Ag composite structure film was directly grown on indium tin oxide glass substrate by a simple hydrothermal method and electrodeposition method. The film was employed for the first time as a photocathode for photoelectrochemical (PEC) water splitting to generate hydrogen. The photocurrent density of the Co 3 O 4 /CuO/Ag composite structure achieved -5.13 mA cm -2 at -0.2 V vs. RHE, which is roughly 12.8 times that of 1D Co 3 O 4 nanowires and 3.31 times Co 3 O 4 /CuO heterojunction photocathodes. The enhanced PEC performance of this Co 3 O 4 /CuO/Ag composite structure ascribes increased light-harvesting and light-absorption, distensible photoresponse range, decreased interface charge transfer resistance, and improved photogenerated electron-hole pairs transfer and separation.

  12. Design and fabrication of prototype 6×6 cm2 microchannel plate photodetector with bialkali photocathode for fast timing applications

    International Nuclear Information System (INIS)

    Xie, Junqi; Byrum, Karen; Demarteau, Marcel; Gregar, Joseph; May, Edward; Virgo, Mathew; Wagner, Robert; Walters, Dean; Wang, Jingbo; Xia, Lei; Zhao, Huyue

    2015-01-01

    Planar microchannel plate-based photodetectors with a bialkali photocathode are able to achieve photon detection with very good time and position resolution. A 6×6 cm 2 photodetector production facility was designed and built at Argonne National Laboratory. Small form-factor MCP-based photodetectors completely constructed out of glass were designed and prototypes were successfully fabricated. Knudsen effusion cells were incorporated in the photocathode growth chamber to achieve uniform and high quantum efficiency photocathodes. The thin film uniformity was simulated and measured for an antimony film deposition, showing uniformity of better than 10%. Several prototype devices with bialkali photocathodes have been fabricated with the described system and their characteristics were evaluated in the large signal (multi-PE) limit. A typical prototype device exhibits time-of-flight resolution of ~27 psec and differential time resolution of ~9 psec, corresponding to spatial resolution of ~0.65 mm

  13. Heat load of a GaAs photocathode in an SRF electron gun

    International Nuclear Information System (INIS)

    Wang Erdong; Zhao Kui; Jorg Kewisch; Ilan Ben-Zvi; Andrew Burrill; Trivini Rao; Wu Qiong; Animesh Jain; Ramesh Gupta; Doug Holmes

    2011-01-01

    A great deal of effort has been made over the last decades to develop a better polarized electron source for high energy physics. Several laboratories operate DC guns with a gallium arsenide photocathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved by using a superconducting radio frequency (SRF) electron gun, which delivers beams of a higher brightness than that from DC guns because the field gradient at the cathode is higher. SRF guns with metal and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since a bulk gallium arsenide (GaAs) photocathode is normal conducting, a problem arises from the heat load stemming from the cathode. We present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and verification by measuring the quality factor of the gun with and without the cathode at 2 K. We simulate heat generation and flow from the GaAs cathode using the ANSYS program. By following the findings with the heat load model, we designed and fabricated a new cathode holder (plug) to decrease the heat load from GaAs. (authors)

  14. Influence of air exposure on CsI photocathodes

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Yuguang, E-mail: ygxie@mail.ihep.ac.cn [State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, CAS and University of Science and Technology of China, Beijing 100049 (China); Zhang, Aiwu; Liu, Yingbiao [State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, CAS and University of Science and Technology of China, Beijing 100049 (China); Graduate University of Chinese Academy of Sciences, Beijing 100049 (China); Liu, Hongbang [Graduate University of Chinese Academy of Sciences, Beijing 100049 (China); Guangxi University, Naning 530004 (China); Hu, Tao; Zhou, Li; Cai, Xiao; Fang, Jian; Yu, Boxiang [State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, CAS and University of Science and Technology of China, Beijing 100049 (China); Ge, Yongshuai [State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, CAS and University of Science and Technology of China, Beijing 100049 (China); Graduate University of Chinese Academy of Sciences, Beijing 100049 (China); Lue, Qiwen [Shanxi University, Taiyuan 030006 (China); Sun, Xilei; Sun, Lijun; Xue, Zheng [State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, CAS and University of Science and Technology of China, Beijing 100049 (China); Xie, Yigang; Zheng, Yangheng [Graduate University of Chinese Academy of Sciences, Beijing 100049 (China); Lue, Junguang [State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, CAS and University of Science and Technology of China, Beijing 100049 (China)

    2012-10-11

    We investigate the influence of air exposure on the quantum efficiency (QE) and surface morphology of CsI photocathodes (PCs), at relative humidities (RH) higher than 80% down to nearly 3% (both at room temperature) and a 60 Degree-Sign C baking condition. By atomic force microscopy (AFM) surface analysis, it is clearly seen that RH >60% speeds up water film formation and CsI dissolution on the surface of the photocathode at the minute scale, while both grain size and QE change slowly at RH <30% at the hour scale. In the baking environment, the peak QE decreases less than 1.5% (absolute) within one week, and a stainless steel substrate and electron beam evaporation technique tend to effectively weaken the influence of air. With an Au-coated FR-4 substrate, the QE degradation is found to strongly depend on wavelength in the range of 120-210 nm. According to spectra of X-ray photoelectron spectroscopy (XPS), an excess of cesium was observed and the chemical reaction between water and CsI when exposed to humid air is proved. It is found that carbon, and not H{sub 2}O or O{sub 2}, is the main pollutant in the baking condition.

  15. Design and modeling of a 17 GHz photocathode RF gun

    International Nuclear Information System (INIS)

    Lin, C.L.; Chen, S.C.; Wurtele, J.S.; Temkin, R.; Danly, B.

    1991-01-01

    The performance of a high-frequency (17 GHz), high accelerating gradient (250 MV/m) photocathode RF gun is studied with the particle-in-cell code MAGIC. For the parameter regime of interest, i.e. bunch charge smaller than 1 nC and bunch length shorter than 2 ps, space-charge forces and finite bunch length effects are less significant in determining the beam quality than nonlinear RF forces are. The cavity geometry, RF phase for photoemission, cathode size, and current density are being optimized to obtain high quality beams. Preliminary results are presented

  16. Positron lifetime study of neutron-irradiated molybdenum

    International Nuclear Information System (INIS)

    Hinode, Kenji; Tanigawa, Shoichiro; Kumakura, Hiroaki; Doyama, Masao; Shiraishi, Kensuke.

    1978-01-01

    Annealing behavior of fast-neutron-irradiated molybdenum was studied by means of positron lifetime technique. It was found that Stage III annealing can be mainly identified as the vacancy migration process from the detailed analyses of data. The void growth after successive high temperature annealings was clearly detected through the changes of positron lifetime parameters. An attempt to analyse the size distribution of voids from positron lifetime spectra was presented, and discussions on the evaluation of void concentration from positron data are also given. (author)

  17. Novel p-n heterojunction copper phosphide/cuprous oxide photocathode for solar hydrogen production.

    Science.gov (United States)

    Chen, Ying-Chu; Chen, Zhong-Bo; Hsu, Yu-Kuei

    2018-08-01

    A Copper phosphide (Cu 3 P) micro-rod (MR) array, with coverage by an n-Cu 2 O thin layer by electrodeposition as a photocathode, has been directly fabricated on copper foil via simple electro-oxidation and phosphidation for photoelectrochemical (PEC) hydrogen production. The morphology, structure, and composition of the Cu 3 P/Cu 2 O heterostructure are systematically analyzed using a scanning electron microscope (SEM), X-ray diffraction and X-ray photoelectron spectra. The PEC measurements corroborate that the p-Cu 3 P/n-Cu 2 O heterostructural photocathode illustrates efficient charge separation and low charge transfer resistance to achieve the highest photocurrent of 430 μA cm -2 that is greater than other transition metal phosphide materials. In addition, a detailed energy diagram of the p-Cu 3 P/n-Cu 2 O heterostructure was investigated using Mott-Schottky analysis. Our study paves the way to explore phosphide-based materials in a new class for solar energy applications. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. CdTeO3 Deposited Mesoporous NiO Photocathode for a Solar Cell

    Directory of Open Access Journals (Sweden)

    Chuan Zhao

    2014-01-01

    Full Text Available Semiconductor sensitized NiO photocathodes have been fabricated by successive ionic layer adsorption and reaction (SILAR method depositing CdTeO3 quantum dots onto mesoscopic NiO films. A solar cell using CdTeO3 deposited NiO mesoporous photocathode has been fabricated. It yields a photovoltage of 103.7 mV and a short-circuit current density of 0.364 mA/cm2. The incident photon to current conversion efficiency (IPCE value is found to be 12% for the newly designed NiO/CdTeO3 solar cell. It shows that the p-type NiO/CdTeO3 structure could be successfully utilized to fabricate p-type solar cell.

  19. Heat enhancement of radiation resistivity of evaporated CsI, KI and KBr photocathodes

    CERN Document Server

    Tremsin, A S

    2000-01-01

    The photoemissive stability of as-deposited and heat-treated CsI, KI and KBr evaporated thin films under UV radiation is examined in this paper. After the deposition, some photocathodes were annealed for several hours at 90 deg. C in vacuum and their performance was then compared to the performance of non-heated samples. We observed that the post-evaporation thermal treatment not only increases the photoyield of CsI and KI photocathodes in the spectral range of 115-190 nm, but also reduces CsI, KI and KBr photocurrent degradation that occurs after UV irradiation. KBr evaporated layers appeared to be more radiation-resistant than CsI and KI layers. Post-deposition heat treatment did not result in any significant variation of KBr UV sensitivity.

  20. Observation of Cherenkov rings using a low-pressure parallel-plate chamber and a solid cesium-iodide photocathode

    International Nuclear Information System (INIS)

    Lockyer, N.S.; Millan, J.E.; Lu, C.; McDonald, K.T.; Lopez, A.

    1993-01-01

    We have observed Cherenkov rings from minimum-ionizing particles using a low-pressure, parallel-plate pad-chamber with a cesium-iodide solid photocathode. This detector is blind to minimum-ionizing particles, and sensitive to Cherenkov photons of wavelengths 170-210 nm. An average of 5 photoelectrons per Cherenkov ring were detected using a 2-cm-thick radiator of liquid C 6 F 14 . This paper reports on the chamber construction, photocathode preparation and testbeam results. (orig.)

  1. High time resolution beam-based measurement of the rf-to-laser jitter in a photocathode rf gun

    Directory of Open Access Journals (Sweden)

    Zhen Zhang

    2014-03-01

    Full Text Available Characterizing the rf-to-laser jitter in the photocathode rf gun and its possible origins is important for improving the synchronization and beam quality of the linac based on the photocathode rf gun. A new method based on the rf compression effect in the photocathode rf gun is proposed to measure the rf-to-laser jitter in the gun. By taking advantage of the correlation between the rf compression and the laser injection phase, the error caused by the jitter of the accelerating field in the gun is minimized and thus 10 fs time resolution is expected. Experimental demonstration at the Tsinghua Thomson scattering x-ray source with a time resolution better than 35 fs is reported in this paper. The experimental results are successfully used to obtain information on the possible cause of the jitter and the accompanying drifts.

  2. Engineering Design and Fabrication of an Ampere-Class Superconducting Photocathode Electron Gun

    International Nuclear Information System (INIS)

    Ben-Zvi, I.

    2008-01-01

    Over the past three years, Advanced Energy Systems and Brookhaven National Laboratory (BNL) have been collaborating on the design of an Ampere- class superconducting photocathode electron gun. BNL performed the physics design of the overall system and RF cavity under prior programs. Advanced Energy Systems (AES) is currently responsible for the engineering design and fabrication of the electron gun under contract to BNL. We will report on the engineering design and fabrication status of the superconducting photocathode electron gun. The overall configuration of the cryomodule will be reviewed. The layout of the hermitic string, space frame, shielding package, and cold mass will be discussed. The engineering design of the gun cavity and removable cathode will be presented in detail and areas of technical risk will be highlighted. Finally, the fabrication sequence and fabrication status of the gun cavity will be discussed

  3. A Satellite Mortality Study to Support Space Systems Lifetime Prediction

    Science.gov (United States)

    Fox, George; Salazar, Ronald; Habib-Agahi, Hamid; Dubos, Gregory

    2013-01-01

    Estimating the operational lifetime of satellites and spacecraft is a complex process. Operational lifetime can differ from mission design lifetime for a variety of reasons. Unexpected mortality can occur due to human errors in design and fabrication, to human errors in launch and operations, to random anomalies of hardware and software or even satellite function degradation or technology change, leading to unrealized economic or mission return. This study focuses on data collection of public information using, for the first time, a large, publically available dataset, and preliminary analysis of satellite lifetimes, both operational lifetime and design lifetime. The objective of this study is the illustration of the relationship of design life to actual lifetime for some representative classes of satellites and spacecraft. First, a Weibull and Exponential lifetime analysis comparison is performed on the ratio of mission operating lifetime to design life, accounting for terminated and ongoing missions. Next a Kaplan-Meier survivor function, standard practice for clinical trials analysis, is estimated from operating lifetime. Bootstrap resampling is used to provide uncertainty estimates of selected survival probabilities. This study highlights the need for more detailed databases and engineering reliability models of satellite lifetime that include satellite systems and subsystems, operations procedures and environmental characteristics to support the design of complex, multi-generation, long-lived space systems in Earth orbit.

  4. Development of Thin Film Amorphous Silicon Tandem Junction Based Photocathodes Providing High Open-Circuit Voltages for Hydrogen Production

    Directory of Open Access Journals (Sweden)

    F. Urbain

    2014-01-01

    Full Text Available Hydrogenated amorphous silicon thin film tandem solar cells (a-Si:H/a-Si:H have been developed with focus on high open-circuit voltages for the direct application as photocathodes in photoelectrochemical water splitting devices. By temperature variation during deposition of the intrinsic a-Si:H absorber layers the band gap energy of a-Si:H absorber layers, correlating with the hydrogen content of the material, can be adjusted and combined in a way that a-Si:H/a-Si:H tandem solar cells provide open-circuit voltages up to 1.87 V. The applicability of the tandem solar cells as photocathodes was investigated in a photoelectrochemical cell (PEC measurement set-up. With platinum as a catalyst, the a-Si:H/a-Si:H based photocathodes exhibit a high photocurrent onset potential of 1.76 V versus the reversible hydrogen electrode (RHE and a photocurrent of 5.3 mA/cm2 at 0 V versus RHE (under halogen lamp illumination. Our results provide evidence that a direct application of thin film silicon based photocathodes fulfills the main thermodynamic requirements to generate hydrogen. Furthermore, the presented approach may provide an efficient and low-cost route to solar hydrogen production.

  5. Nuclear Power Plant Lifetime Management Study (I)

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung Yull; Jeong, Ill Seok; Jang, Chang Heui; Song, Taek Ho; Song, Woo Young [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Jin, Tae Eun [Korea Power Engineering Company Consulting and Architecture Engineers, (Korea, Republic of); Kim, Woo Chul [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    As the operation-year of nuclear power plant increases and finding sites for new nuclear power plant becomes harder, a comprehensive and systematic nuclear plant lifetime management(PLIM) program including life extension has to be established for stable and safe supply of electricity. A feasibility study was conducted to systematically evaluate technical, economic and regulatory aspect of plant lifetime managements and plant life extension for Kori-1 nuclear power plant. For technical evaluation of nuclear power plant, 13 major components were selected for lifetime evaluation by screening system. structure, and components(SSCs) of the plant. It was found that except reactor pressure vessel, which needs detailed integrity analysis, and low pressure turbine, which is scheduled to be replaced, 11 out of 13 major components have sufficient service life, for more than 40 years. Because domestic rules and regulations related to license renewal has not yet been written, review on the regulatory aspect of life extensions was conducted using US NRC rules and regulations. A cooperative effort with nuclear regulatory body is needed for early completion of license renewal rules and regulations. For economic evaluation of plant lifetime extension, a computer program was developed and used. It was found that 10 to 20 year of extension operation of Kori-1 nuclear power plant was proved. Based on the results, next phase of plant lifetime management program for detailed lifetime evaluation and presenting detailed implementation schedule for plant refurbishment for lifetime extension should be followed. (author). 74 refs., figs.

  6. Nuclear Power Plant Lifetime Management Study (I)

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung Yull; Jeong, Ill Seok; Jang, Chang Heui; Song, Taek Ho; Song, Woo Young [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Jin, Tae Eun [Korea Power Engineering Company Consulting and Architecture Engineers, (Korea, Republic of); Kim, Woo Chul [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-12-31

    As the operation-year of nuclear power plant increases and finding sites for new nuclear power plant becomes harder, a comprehensive and systematic nuclear plant lifetime management(PLIM) program including life extension has to be established for stable and safe supply of electricity. A feasibility study was conducted to systematically evaluate technical, economic and regulatory aspect of plant lifetime managements and plant life extension for Kori-1 nuclear power plant. For technical evaluation of nuclear power plant, 13 major components were selected for lifetime evaluation by screening system. structure, and components(SSCs) of the plant. It was found that except reactor pressure vessel, which needs detailed integrity analysis, and low pressure turbine, which is scheduled to be replaced, 11 out of 13 major components have sufficient service life, for more than 40 years. Because domestic rules and regulations related to license renewal has not yet been written, review on the regulatory aspect of life extensions was conducted using US NRC rules and regulations. A cooperative effort with nuclear regulatory body is needed for early completion of license renewal rules and regulations. For economic evaluation of plant lifetime extension, a computer program was developed and used. It was found that 10 to 20 year of extension operation of Kori-1 nuclear power plant was proved. Based on the results, next phase of plant lifetime management program for detailed lifetime evaluation and presenting detailed implementation schedule for plant refurbishment for lifetime extension should be followed. (author). 74 refs., figs.

  7. Hot Hole Collection and Photoelectrochemical CO2 Reduction with Plasmonic Au/p-GaN Photocathodes.

    Science.gov (United States)

    DuChene, Joseph S; Tagliabue, Giulia; Welch, Alex J; Cheng, Wen-Hui; Atwater, Harry A

    2018-04-11

    Harvesting nonequilibrium hot carriers from plasmonic-metal nanostructures offers unique opportunities for driving photochemical reactions at the nanoscale. Despite numerous examples of hot electron-driven processes, the realization of plasmonic systems capable of harvesting hot holes from metal nanostructures has eluded the nascent field of plasmonic photocatalysis. Here, we fabricate gold/p-type gallium nitride (Au/p-GaN) Schottky junctions tailored for photoelectrochemical studies of plasmon-induced hot-hole capture and conversion. Despite the presence of an interfacial Schottky barrier to hot-hole injection of more than 1 eV across the Au/p-GaN heterojunction, plasmonic Au/p-GaN photocathodes exhibit photoelectrochemical properties consistent with the injection of hot holes from Au nanoparticles into p-GaN upon plasmon excitation. The photocurrent action spectrum of the plasmonic photocathodes faithfully follows the surface plasmon resonance absorption spectrum of the Au nanoparticles and open-circuit voltage studies demonstrate a sustained photovoltage during plasmon excitation. Comparison with Ohmic Au/p-NiO heterojunctions confirms that the vast majority of hot holes generated via interband transitions in Au are sufficiently hot to inject above the 1.1 eV interfacial Schottky barrier at the Au/p-GaN heterojunction. We further investigated plasmon-driven photoelectrochemical CO 2 reduction with the Au/p-GaN photocathodes and observed improved selectivity for CO production over H 2 evolution in aqueous electrolytes. Taken together, our results offer experimental validation of photoexcited hot holes more than 1 eV below the Au Fermi level and demonstrate a photoelectrochemical platform for harvesting hot carriers to drive solar-to-fuel energy conversion.

  8. Transmission photocathodes based on stainless steel mesh and quartz glass coated with N-doped DLC thin films prepared by reactive magnetron sputtering

    Science.gov (United States)

    Balalykin, N. I.; Huran, J.; Nozdrin, M. A.; Feshchenko, A. A.; Kobzev, A. P.; Arbet, J.

    2016-03-01

    The influence was investigated of N-doped diamond-like carbon (DLC) films properties on the quantum efficiency of a prepared transmission photocathode. N-doped DLC thin films were deposited on a silicon substrate, a stainless steel mesh and quartz glass (coated with 5 nm thick Cr adhesion film) by reactive magnetron sputtering using a carbon target and gas mixture Ar, 90%N2+10%H2. The elements' concentration in the films was determined by RBS and ERD. The quantum efficiency was calculated from the measured laser energy and the measured cathode charge. For the study of the vectorial photoelectric effect, the quartz type photocathode was irradiated by intensive laser pulses to form pin-holes in the DLC film. The quantum efficiency (QE), calculated at a laser energy of 0.4 mJ, rose as the nitrogen concentration in the DLC films was increased and rose dramatically after the micron-size perforation in the quartz type photocathodes.

  9. High power testing of a 17 GHz photocathode RF gun

    International Nuclear Information System (INIS)

    Chen, S.C.; Danly, B.G.; Gonichon, J.

    1995-01-01

    The physics and technological issues involved in high gradient particle acceleration at high microwave (RF) frequencies are under study at MIT. The 17 GHz photocathode RF gun has a 1 1/2 cell (π mode) room temperature cooper cavity. High power tests have been conducted at 5-10 MW levels with 100 ns pulses. A maximum surface electric field of 250 MV/m was achieved. This corresponds to an average on-axis gradient of 150 MeV/m. The gradient was also verified by a preliminary electron beam energy measurement. Even high gradients are expected in our next cavity design

  10. Improved Ion Resistance for III-V Photocathodes in High Current Guns

    Energy Technology Data Exchange (ETDEWEB)

    Mulhollan, Gregory, A.

    2012-11-16

    The two photocathode test systems were modified, baked and recommissioned. The first system was dedicated to ion studies and the second to electron stimulated recovery (ESR) work. The demonstration system for the electron beam rejuvenation was set up, tested and demonstrated to one of the SSRL team (Dr. Kirby) during a site visit. The requisite subsystems were transferred to SSRL, installed and photoemission studies conducted on activated surfaces following electron beam exposure. Little surface chemistry change was detected in the photoemission spectra following the ESR process. The yield mapping system for the ion (and later, the electron beam rejuvenation) studies was implemented and use made routine. Ion species and flux measurements were performed for H, He, Ne, Ar, Kr and Xe ions at energies of 0.5, 1.0 and 2.0 kV. Gas induced photoyield measurements followed each ion exposure measurement. These data permit the extraction of photoyield induced change per ion (by species) at the measured energies. Electron beam induced rejuvenation was first demonstrated in the second chamber with primary electron beam energy and dependency investigations following. A Hiden quadrupole mass spectrometer for the electron stimulated desorption (ESD) measurements was procured. The UHV test systems needed for subsequent measurements were configured, baked, commissioned and utilized for their intended purposes. Measurements characterizing the desorption products from the ESD process and secondary electron (SE) yield at the surfaces of negative electron affinity GaAs photocathodes have been performed. One US Utility Patent was granted covering the ESR process.

  11. Effect of gold photocathode contamination on a flat spectral response X-ray diode

    Science.gov (United States)

    Wang, Kun-lun; Zhang, Si-qun; Zhou, Shao-tong; Huang, Xian-bin; Ren, Xiao-dong; Dan, Jia-kun; Xu, Qiang

    2018-03-01

    A detector with an approximately flat spectral response is important for diagnosing intense thermal X-ray flux. A flat-spectral-response X-ray diode (FSR-XRD) utilizes a gold photocathode X-ray diode and a specially configured gold filter to give rise to a nearly flat spectral response in the photon energy range of 100-4000 eV. It has been observed that the spectral responses of several FSR-XRDs changed after a few shots of z-pinch experiments on the Primary Test Stand facility. This paper presents an analysis of the changes by fitting the spectral responses of the gold photocathodes using a model with a free parameter which characterizes the thickness of the contamination. The spectral responses of FSR-XRDs were calibrated with synchrotron radiation, and several cleaning methods were tested with the calibration. Considering the results of model and cleaning, it may be anticipated that contamination was the major reason of the response changing. Contamination worsened the flatness of the spectral response of the FSR-XRD and decreased the averaged response, hence it is important to avoid contamination. Current results indicate a requirement of further study of the contamination.

  12. Photocathodic Protection of 304 Stainless Steel by Bi2S3/TiO2 Nanotube Films Under Visible Light.

    Science.gov (United States)

    Li, Hong; Wang, Xiutong; Wei, Qinyi; Hou, Baorong

    2017-12-01

    We report the preparation of TiO 2 nanotubes coupled with a narrow bandgap semiconductor, i.e., Bi 2 S 3 , to improve the photocathodic protection property of TiO 2 for metals under visible light. Bi 2 S 3 /TiO 2 nanotube films were successfully synthesized using the successive ionic layer adsorption and reaction (SILAR) method. The morphology and structure of the composite films were studied by scanning electron microscopy and X-ray diffraction, respectively. UV-visible diffuse reflectance spectra were recorded to analyze the optical absorption property of the composite films. In addition, the influence of Bi 2 S 3 deposition cycles on the photoelectrochemical and photocathodic protection properties of the composite films was also studied. Results revealed that the heterostructure comprised crystalline anatase TiO 2 and orthorhombic Bi 2 S 3 and exhibited a high visible light response. The photocurrent density of Bi 2 S 3 /TiO 2 was significantly higher than that of pure TiO 2 under visible light. The sensitization of Bi 2 S 3 enhanced the separation efficiency of the photogenerated charges and photocathodic protection properties of TiO 2 . The Bi 2 S 3 /TiO 2 nanotubes prepared by SILAR deposition with 20 cycles exhibited the optimal photogenerated cathodic protection performance on the 304 stainless steel under visible light.

  13. Photocathodic Protection of 304 Stainless Steel by Bi2S3/TiO2 Nanotube Films Under Visible Light

    Science.gov (United States)

    Li, Hong; Wang, Xiutong; Wei, Qinyi; Hou, Baorong

    2017-01-01

    We report the preparation of TiO2 nanotubes coupled with a narrow bandgap semiconductor, i.e., Bi2S3, to improve the photocathodic protection property of TiO2 for metals under visible light. Bi2S3/TiO2 nanotube films were successfully synthesized using the successive ionic layer adsorption and reaction (SILAR) method. The morphology and structure of the composite films were studied by scanning electron microscopy and X-ray diffraction, respectively. UV-visible diffuse reflectance spectra were recorded to analyze the optical absorption property of the composite films. In addition, the influence of Bi2S3 deposition cycles on the photoelectrochemical and photocathodic protection properties of the composite films was also studied. Results revealed that the heterostructure comprised crystalline anatase TiO2 and orthorhombic Bi2S3 and exhibited a high visible light response. The photocurrent density of Bi2S3/TiO2 was significantly higher than that of pure TiO2 under visible light. The sensitization of Bi2S3 enhanced the separation efficiency of the photogenerated charges and photocathodic protection properties of TiO2. The Bi2S3/TiO2 nanotubes prepared by SILAR deposition with 20 cycles exhibited the optimal photogenerated cathodic protection performance on the 304 stainless steel under visible light.

  14. Positron lifetime studies on thorium oxide powders

    International Nuclear Information System (INIS)

    Upadhyaya, D.D.; Muraleedharan, R.V.; Sharma, B.D.

    1982-01-01

    Positron lifetime spectra have been studied for ThO 2 powders, calcined at different temperatures and having different particle sizes. Three lifetime components could be resolved, the longest component being of low intensity. An observed strong dependence on the particle size of the annihilation process and the variation of positronium diffusion constant is explained on the basis of defect density variations in these powders. (author)

  15. Lifetime of MCP-PMTs and other performance features

    Science.gov (United States)

    Lehmann, A.; Böhm, M.; Eyrich, W.; Miehling, D.; Pfaffinger, M.; Stelter, S.; Uhlig, F.; Ali, A.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kreutzfeld, K.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.

    2018-02-01

    The bar PANDA experiment at FAIR will use DIRC detectors for the separation of hadrons. The compactness of the bar PANDA detector requires the image planes of these detectors to be placed inside the magnetic field of the solenoid. Due to this and other boundary conditions MCP-PMTs were identified as the only suitable photon sensors. Until recently the major obstacle for an application of MCP-PMTs in high rate experiments like bar PANDA were serious aging problems which led to damage at the photo-cathode and a fast declining quantum efficiency as the integrated anode charge (IAC) increased. With new countermeasures against the aging, in particular due to the application of an atomic layer deposition (ALD) technique to coat the MCP pores, the lifetime of MCP-PMTs has meanwhile increased by a factor >50 which is fully sufficient for bar PANDA. The recent results of our long-term lifetime measurements are discussed. New 2-inch MCP-PMT prototypes from Hamamatsu show an encouraging behavior. However, the currently best performing MCP-PMT is a 2-inch PHOTONIS tube with two ALD-layers which reaches an IAC of >16 C/cm2 without any visible sign of aging. In the second part of these proceedings a new data acquisition system of the PADIWA/TRB type is presented which allows a quasi-parallel measurement of many MCP-PMT performance parameters. Especially unwanted effects like dark-count rate, crosstalk, ion after-pulsing, and recoil electrons can be studied in more detail than ever before. Exemplary results for these parameters are shown. The discussed DAQ system will be used for the comprehensive data quality checks of the MCP-PMTs being built into the DIRCs.

  16. A review of radio-frequency photocathode electron sources

    International Nuclear Information System (INIS)

    Stovall, J.

    1992-01-01

    A review of this topic at the last conference in this series reported considerable progress in R and D programs aimed at producing high-current low-emittance electron beams using photocathode rf guns. At present at least 20 such projects are under way world wide and at least 6 photoinjectors are presently in operation. This paper reviews some of the choices that must be made in optimizing the design of the accelerating structure for a photoinjector based on the current state of knowledge. (Author) 5 refs., 9 figs., 3 tabs

  17. Generation of a femtosecond electron microbunch train from a photocathode using twofold Michelson interferometer

    Directory of Open Access Journals (Sweden)

    M. Shevelev

    2017-10-01

    Full Text Available The interest in producing ultrashort electron bunches has risen sharply among scientists working on the design of high-gradient wakefield accelerators. One attractive approach generating electron bunches is to illuminate a photocathode with a train of femtosecond laser pulses. In this paper we describe the design and testing of a laser system for an rf gun based on a commercial titanium-sapphire laser technology. The technology allows the production of four femtosecond laser pulses with a continuously variable pulse delay. We also use the designed system to demonstrate the experimental generation of an electron microbunch train obtained by illuminating a cesium-telluride semiconductor photocathode. We use conventional diagnostics to characterize the electron microbunches produced and confirm that it may be possible to control the main parameter of an electron microbunch train.

  18. Generation of a femtosecond electron microbunch train from a photocathode using twofold Michelson interferometer

    Science.gov (United States)

    Shevelev, M.; Aryshev, A.; Terunuma, N.; Urakawa, J.

    2017-10-01

    The interest in producing ultrashort electron bunches has risen sharply among scientists working on the design of high-gradient wakefield accelerators. One attractive approach generating electron bunches is to illuminate a photocathode with a train of femtosecond laser pulses. In this paper we describe the design and testing of a laser system for an rf gun based on a commercial titanium-sapphire laser technology. The technology allows the production of four femtosecond laser pulses with a continuously variable pulse delay. We also use the designed system to demonstrate the experimental generation of an electron microbunch train obtained by illuminating a cesium-telluride semiconductor photocathode. We use conventional diagnostics to characterize the electron microbunches produced and confirm that it may be possible to control the main parameter of an electron microbunch train.

  19. Analysis of emittance compensation and simulation results to photo-cathode RF gun

    CERN Document Server

    LiuShengGuang

    2002-01-01

    The emittance compensation technology will be used on the photo-cathode RF gun for Shanghai SDUV-FEL. The space charge force and its effect on electron beam transverse emittance in RF gun is studied, the principle of emittance compensation in phase-space is discussed. The authors have designed a compensation solenoid and calculated its magnetic field distribution. Its performance has been studied by the code PARMELA. A simulation result indicates that the normalized transverse RMS emittance for electron beam of 1.5 nC is 1.612 pi mm centre dot mrad, electron energy E = 5.71 MeV

  20. Ultrathin MoS2-coated Ag@Si nanosphere arrays as an efficient and stable photocathode for solar-driven hydrogen production.

    Science.gov (United States)

    Zhou, Qingwei; Su, Shaoqiang; Hu, Die; Lin, Lin; Yan, Zhibo; Gao, Xingsen; Zhang, Zhang; Liu, Jun-Ming

    2018-01-30

    Solar-driven photoelectrochemical (PEC) water splitting has attracted a great deal of attention recently. Silicon (Si) is an ideal light absorber for solar energy conversion. However, the poor stability and inefficient surface catalysis of Si photocathodes for the hydrogen evolution reaction (HER) have remained key challenges. Alternatively, MoS 2 has been reported to exhibit excellent catalysis performance if sufficient active sites for the HER are available. Here, ultrathin MoS 2 nanoflakes are directly synthesized to coat arrays of Ag-core Si-shell nanospheres (Ag@Si NSs) by using chemical vapor deposition. Due to the high surface area ratio and large curvature of these NSs, the as-grown MoS 2 nanoflakes can accommodate more active sites. In addition, the high-quality coating of MoS 2 nanoflakes on the Ag@Si NSs protects the photocathode from damage during the PEC reaction. An photocurrent density of 33.3 mA cm -2 at a voltage of -0.4 V is obtained versus the reversible hydrogen electrode. The as-prepared nanostructure as a hydrogen photocathode is evidenced to have high stability over 12 h PEC performance. This work opens up opportunities for composite photocathodes with high activity and stability using cheap and stable co-catalysts.

  1. Ultra-thin MoS2 coated Ag@Si nanosphere arrays as efficient and stable photocathode for solar-driven hydrogen production.

    Science.gov (United States)

    Zhou, Qingwei; Su, Shaoqiang; Hu, Die; Lin, Lin; Yan, Zhibo; Gao, Xingsen; Zhang, Zhang; Liu, Junming

    2018-01-02

    Solar-driven photoelectrochemical (PEC) water splitting has recently attracted much attention. Silicon (Si) is an ideal light absorber for solar energy conversion. However, the poor stability and inefficient surface catalysis of Si photocathode for hydrogen evolution reaction (HER) have been remained as the key challenges. Alternatively, MoS2 has been reported to exhibit the excellent catalysis performance if sufficient active sites for the HER are available. Here, ultra-thin MoS2 nanoflakes are directly synthesized to coat on the arrays of Ag-core Si-shell nanospheres (Ag@Si NSs) using the chemical vapor deposition (CVD). Due to the high surface area ratio and large curvature of these NSs, the as-grown MoS2 nanoflakes can accommodate more active sites. Meanwhile, the high-quality coating of MoS2 nanoflakes on the Ag@Si NSs protects the photocathode from damage during the PEC reaction. A high efficiency with a photocurrent of 33.3 mA cm-2 at a voltage of -0.4 V vs. the reversible hydrogen electrode is obtained. The as-prepared nanostructure as hydrogen photocathode is evidenced to have high stability over 12 hour PEC performance. This work opens opportunities for composite photocathode with high activity and stability using cheap and stable co-catalysts. © 2017 IOP Publishing Ltd.

  2. Positron lifetime studies of electron irradiated copper

    International Nuclear Information System (INIS)

    Hadnagy, T.D.

    1976-01-01

    Single-crystal copper was irradiated with 4.5-MeV electrons producing simple Frenkel defects as well as a significant concentration of divacancies. Mean positron lifetime characteristics, which are sensitive to the presence of vacancies and multivacancies in copper, was monitored after isochronal anneals between 80 and 800 0 K to determine the relative change of characteristic mean lifetimes and their associated intensities. Also a study of the dependence of the mean positron lifetime on the total electron fluence was made and compared with existing theories relating these lifetimes to vacancy or multivacancy concentrations. Numerical data from curve fitting procedures using a conventional trapping model for defect-induced changes in positron lifetimes indicate that upon irradiation with 4.5-MeV electrons at 80 0 K, about 8 percent of the defects produced are divacancy units. Divacancy units appear to be several times more effective in trapping positrons than are monovacancies. Further, the experimental data suggest that the stage III annealing processes in electron-irradiated copper most probably involve the motion and removal of both monovacancies and divacancies. A conglomerate (multivacancy) unit appears to exist as a stable entity even after annealing procedures are carried out at temperatures slightly above the stage III region. Such a stable unit could serve as a nucleation center for the appearance of voids

  3. Heat load of a P-doped GaAs photocathode in SRF electron gun

    International Nuclear Information System (INIS)

    Wang, E.; Ben-Zvi, I.; Kewisch, J.; Burrill, A.; Rao, T.; Wu, Q.; Jain, A.; Gupta, R.; Holmes, D.

    2010-01-01

    Many efforts were made over the last decades to develop a better polarized electron source for the high energy physics. Several laboratories operate DC guns with the Gallium-Arsenide photo-cathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved using a Superconducting RF electron gun, which delivers beams of higher brightness than DC guns does, because the field gradient at the cathode is higher. SRF guns with metal cathodes and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since the cathode will be normal conducting, the problem about the heat load stemming from the cathode arises. We present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and the verification by measuring the quality factor of the gun with and without cathode.

  4. Photocurrent Enhancement by a Rapid Thermal Treatment of Nanodisk-Shaped SnS Photocathodes.

    Science.gov (United States)

    Patel, Malkeshkumar; Kumar, Mohit; Kim, Joondong; Kim, Yu Kwon

    2017-12-21

    Photocathodes made from the earth-abundant, ecofriendly mineral tin monosulfide (SnS) can be promising candidates for p/n-type photoelectrochemical cells because they meet the strict requirements of energy band edges for each individual photoelectrode. Herein we fabricated SnS-based cell that exhibited a prolonged photocurrent for 3 h at -0.3 V vs the reversible hydrogen electrode (RHE) in a 0.1 M HCl electrolyte. An enhancement of the cathodic photocurrent from 2 to 6 mA cm -2 is observed through a rapid thermal treatment. Mott-Schottky analysis of SnS samples revealed an anodic shift of 0.7 V in the flat band potential under light illumination. Incident photon-to-current conversion efficiency (IPCE) analysis indicates that an efficient charge transfer appropriate for solar hydrogen generation occurs at the -0.3 V vs RHE potential. This work shows that SnS is a promising material for photocathode in PEC cells and its performance can be enhanced via simple postannealing.

  5. Improved Electron Yield and Spin-Polarization from III-V Photocathodes via Bias Enhanced Carrier Drift: Final Report

    International Nuclear Information System (INIS)

    Mulhollan, Gregory A.

    2006-01-01

    In this DOE STTR program, Saxet Surface Science, with the Stanford Linear Accelerator Center as partner, designed, built and tested photocathode structures such that optimal drift-enhanced spin-polarization from GaAs based photoemitters was achieved with minimal bias supply requirements. The forward bias surface grid composition was optimized for maximum polarization and yield, together with other construction parameters including doping profile. This program has culminated in a cathode bias structure affording increased electron spin polarization when applied to III-V based photocathodes. The optimized bias structure has been incorporated into a cathode mounting and biasing design for use in a polarized electron gun.

  6. Comparison of blue-green response between transmission-mode GaAsP- and GaAs-based photocathodes grown by molecular beam epitaxy

    Science.gov (United States)

    Gang-Cheng, Jiao; Zheng-Tang, Liu; Hui, Guo; Yi-Jun, Zhang

    2016-04-01

    In order to develop the photodetector for effective blue-green response, the 18-mm-diameter vacuum image tube combined with the transmission-mode Al0.7Ga0.3As0.9 P 0.1/GaAs0.9 P 0.1 photocathode grown by molecular beam epitaxy is tentatively fabricated. A comparison of photoelectric property, spectral characteristic and performance parameter between the transmission-mode GaAsP-based and blue-extended GaAs-based photocathodes shows that the GaAsP-based photocathode possesses better absorption and higher quantum efficiency in the blue-green waveband, combined with a larger surface electron escape probability. Especially, the quantum efficiency at 532 nm for the GaAsP-based photocathode achieves as high as 59%, nearly twice that for the blue-extended GaAs-based one, which would be more conducive to the underwater range-gated imaging based on laser illumination. Moreover, the simulation results show that the favorable blue-green response can be achieved by optimizing the emission-layer thickness in a range of 0.4 μm-0.6 μm. Project supported by the National Natural Science Foundation of China (Grant No. 61301023) and the Science and Technology on Low-Light-Level Night Vision Laboratory Foundation, China (Grant No. BJ2014001).

  7. Emittance studies of the BNL/SLAC/UCLA 1.6 cell photocathode rf gun

    International Nuclear Information System (INIS)

    Palmer, D.T.; Miller, R.H.; Wang, X.J.

    1997-01-01

    The symmetrized 1.6 cell S-band photocathode gun developed by the BNL/SLAC/UCLA collaboration is in operation at the Brookhaven Accelerator Test Facility (ATF). A novel emittance compensation solenoid magnet has also been designed, built and is in operation at the ATF. These two subsystems form an emittance compensated photoinjector used for beam dynamics, advanced acceleration and free electron laser experiments at the ATF. The highest acceleration field achieved on the copper cathode is 150 MV/m, and the guns normal operating field is 130 MV/m. The maximum rf pulse length is 3 micros. The transverse emittance of the photoelectron beam were measured for various injection parameters. The 1 nC emittance results are presented along with electron bunch length measurements that indicated that at above the 400 pC, space charge bunch lengthening is occurring. The thermal emittance, ε o , of the copper cathode has been measured

  8. High voltage switch triggered by a laser-photocathode subsystem

    Science.gov (United States)

    Chen, Ping; Lundquist, Martin L.; Yu, David U. L.

    2013-01-08

    A spark gap switch for controlling the output of a high voltage pulse from a high voltage source, for example, a capacitor bank or a pulse forming network, to an external load such as a high gradient electron gun, laser, pulsed power accelerator or wide band radar. The combination of a UV laser and a high vacuum quartz cell, in which a photocathode and an anode are installed, is utilized as triggering devices to switch the spark gap from a non-conducting state to a conducting state with low delay and low jitter.

  9. Study of variables for accelerating lifetime testing of SOFCs

    DEFF Research Database (Denmark)

    Ploner, Alexandra; Hagen, Anke; Hauch, Anne

    Solid oxide fuel cell (SOFC) applications require lifetimes of several years on the system level. A big challenge is to proof/confirm/demonstrate such exceptionally long lifetimes.Accelerated or compressed testing are possible methods. Activities in this area have been carried out without arriving...... at different current load cycling profiles revealed a strong deviation between predicted and measured lifetime [3].In this study, we present a detailed analysis of durability results for degradation mechanisms of single SOFC components as function of operating conditions. Electrochemical impedance data...

  10. Unbiased, complete solar charging of a neutral flow battery by a single Si photocathode

    DEFF Research Database (Denmark)

    Wedege, Kristina; Bae, Dowon; Dražević, Emil

    2018-01-01

    Solar redox flow batteries have attracted attention as a possible integrated technology for simultaneous conversion and storage of solar energy. In this work, we review current efforts to design aqueous solar flow batteries in terms of battery electrolyte capacity, solar conversion efficiency...... and depth of solar charge. From a materials cost and design perspective, a simple, cost-efficient, aqueous solar redox flow battery will most likely incorporate only one semiconductor, and we demonstrate here a system where a single photocathode is accurately matched to the redox couples to allow...... for a complete solar charge. The single TiO2 protected Si photocathode with a catalytic Pt layer can fully solar charge a neutral TEMPO-sulfate/ferricyanide battery with a cell voltage of 0.35 V. An unbiased solar conversion efficiency of 1.6% is obtained and this system represents a new strategy in solar RFBs...

  11. Highly stable copper oxide composite as an effective photocathode for water splitting via a facile electrochemical synthesis strategy

    KAUST Repository

    Zhang, Zhonghai

    2012-01-01

    Hydrogen generation through photoelectrochemical (PEC) water splitting using solar light as an energy resource is believed to be a clean and efficient way to overcome the global energy and environmental problems. Extensive research effort has been focused on n-type metal oxide semiconductors as photoanodes, whereas studies of p-type metal oxide semiconductors as photocathodes where hydrogen is generated are scarce. In this paper, highly efficient and stable copper oxide composite photocathode materials were successfully fabricated by a facile two-step electrochemical strategy, which consists of electrodeposition of a Cu film on an ITO glass substrate followed by anodization of the Cu film under a suitable current density and then calcination to form a Cu 2O/CuO composite. The synthesized Cu 2O/CuO composite was composed of a thin layer of Cu 2O with a thin film of CuO on its top as a protecting coating. The rational control of chemical composition and crystalline orientation of the composite materials was easily achieved by varying the electrochemical parameters, including electrodeposition potential and anodization current density, to achieve an enhanced PEC performance. The best photocathode material among all materials prepared was the Cu 2O/CuO composite with Cu 2O in (220) orientation, which showed a highly stable photocurrent of -1.54 mA cm -2 at a potential of 0 V vs reversible hydrogen electrode at a mild pH under illumination of AM 1.5G. This photocurrent density was more than 2 times that generated by the bare Cu 2O electrode (-0.65 mAcm -2) and the stability was considerably enhanced to 74.4% from 30.1% on the bare Cu 2O electrode. The results of this study showed that the top layer of CuO in the Cu 2O/CuO composite not only minimized the Cu 2O photocorrosion but also served as a recombination inhibitor for the photogenerated electrons and holes from Cu 2O, which collectively explained much enhanced stability and PEC activity of the Cu 2O/CuO composite

  12. Epitaxial Bi2 FeCrO6 Multiferroic Thin Film as a New Visible Light Absorbing Photocathode Material.

    Science.gov (United States)

    Li, Shun; AlOtaibi, Bandar; Huang, Wei; Mi, Zetian; Serpone, Nick; Nechache, Riad; Rosei, Federico

    2015-08-26

    Ferroelectric materials have been studied increasingly for solar energy conversion technologies due to the efficient charge separation driven by the polarization induced internal electric field. However, their insufficient conversion efficiency is still a major challenge. Here, a photocathode material of epitaxial double perovskite Bi(2) FeCrO(6) multiferroic thin film is reported with a suitable conduction band position and small bandgap (1.9-2.1 eV), for visible-light-driven reduction of water to hydrogen. Photoelectrochemical measurements show that the highest photocurrent density up to -1.02 mA cm(-2) at a potential of -0.97 V versus reversible hydrogen electrode is obtained in p-type Bi(2) FeCrO(6) thin film photocathode grown on SrTiO(3) substrate under AM 1.5G simulated sunlight. In addition, a twofold enhancement of photocurrent density is obtained after negatively poling the Bi(2) FeCrO(6) thin film, as a result of modulation of the band structure by suitable control of the internal electric field gradient originating from the ferroelectric polarization in the Bi(2) FeCrO(6) films. The findings validate the use of multiferroic Bi(2) FeCrO(6) thin films as photocathode materials, and also prove that the manipulation of internal fields through polarization in ferroelectric materials is a promising strategy for the design of improved photoelectrodes and smart devices for solar energy conversion. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Trojan horse underdense plasma photocathode acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Karger, Oliver [Hamburg Univ. (Germany). Inst. fuer Experimentalphysik; DESY, FLA Arbeitsbereich Beschleunigerphysik, Hamburg (Germany); Koenigstein, Thomas; Pretzler, Georg [Duesseldorf Univ. (Germany). Inst. fuer Laser- und Plasmaphysik; Rosenzweig, James B. [California Univ., Los Angeles, CA (United States). Dept. of Physics and Astronomy; Hidding, Bernhard [Hamburg Univ. (Germany). Inst. fuer Experimentalphysik; DESY, FLA Arbeitsbereich Beschleunigerphysik, Hamburg (Germany); California Univ., Los Angeles, CA (United States). Dept. of Physics and Astronomy

    2013-07-01

    Relativistic electron beams with small emittance and size are needed for advanced applications such as free electron lasers (FEL) and other coherent light sources in the X-ray regime. Present laser plasma acceleration schemes are hardly able to provide electron beams of sufficient quality on a stable level. The concept of underdense plasma photocathode acceleration uses a beam-driven plasma wave in a two component gas mixture consisting a low ionisation threshold medium (LIT) and a high ionisation threshold medium (HIT) and a low-energy laser pulse. Shapeable electron bunches with sub-fs-length and unprecedented normalized emittance down to 10{sup -9} m rad can be produced. Based on this method, laboratory-sized-experimental setups may enable performance much better than today's conventional coherent hard X-ray sources. The presentation discusses the basic concept, shows recent numero-analytical results and the R and D towards experimental realization.

  14. Characterization of quantum well structures using a photocathode electron microscope

    Science.gov (United States)

    Spencer, Michael G.; Scott, Craig J.

    1989-01-01

    Present day integrated circuits pose a challenge to conventional electronic and mechanical test methods. Feature sizes in the submicron and nanometric regime require radical approaches in order to facilitate electrical contact to circuits and devices being tested. In addition, microwave operating frequencies require careful attention to distributed effects when considering the electrical signal paths within and external to the device under test. An alternative testing approach which combines the best of electrical and optical time domain testing is presented, namely photocathode electron microscope quantitative voltage contrast (PEMQVC).

  15. Study on the drive laser system of the photocathode-injector used in high gain FEL

    CERN Document Server

    Lu Xiang Yang; Zhao Kui; Wang Li; Quan Sheng Wen; Hao Jian Kui; Zhang Bao Cheng; Chen J

    2002-01-01

    High gain FEL requires high quality electron beam which can be provided only by the RF photocathode gun. The drive laser for electron source plays the key role. In Institute of Heavy Ion Physics of Beijing University, the laser system is required to deliver a 500 mu J, 6-8 ps pulse of UV photons (260 nm) to the cathode. This system mainly consists of a CW, frequency-doubled, diode-pumped Nd:YAG laser, which provides energy to pump a CW mode-locked Ti:sapphire oscillator, Q-switched Nd:YaG pump lasers, a regenerative amplifier and harmonics crystals. To meet the low jitters of pulses (1.0 ps), cavity length of the oscillator should be adjustable to lock the pulse frequency with external RF reference, and a phase stability feedback system is also used

  16. First attempts to combine capillary tubes with photocathodes

    CERN Document Server

    Peskov, Vladimir; Sokolova, T; Radionov, I

    1999-01-01

    We describe our efforts to combine glass capillary plates, operating as a gas amplification structure at approx 1 atm, with photocathodes sensitive to visible light. Such capillary tubes are a by-product of the manufacture of Microchannel Plates and are commercially available. Preliminary tests indicate that gas gains >10 sup 3 could be achieved without photon feedback. With two capillary plates in tandem (double-step multiplication) overall gains up to 10 sup 5 were possible at counting rate <100 Hz/mm sup 2. This approach may open new possibilities for detection of visible photons by gaseous detectors. Potential advantages are: high gains, large sensitive area, high granularity, and insensitivity to magnetic fields.

  17. A study of lifetime within the -12 sec range

    International Nuclear Information System (INIS)

    Dorobantu, V.

    1977-01-01

    Lifetimes of excited nuclear states are studied with a particular emphasis on the determination of nuclear lifetimes by means of the Doppler shift decomposition attenuation method - DSAM - which is based on the mathematical theory of stochastic processes; by its own nature, the emission of recoil nuclei, their motion through an amorphous medium and the detection of gamma rays resulting from these nuclei are all stochastic processes as well. Measurements of lifetimes together with other measurements can supply nuclear structure data, as well as information on the slowing-down process of an energetic ion through a certain material. The experimental tests have been carried out on the Tandem accelerator - IFIN, Bucharest. (author)

  18. Simulations of the BNL/SLAC/UCLA 1.6 cell emittance compensated photocathode RF gun low energy beam line

    International Nuclear Information System (INIS)

    Palmer, D.T.; Miller, R.H.; Winick, H.

    1995-01-01

    A dedicated low energy (2 to 10 MeV) experimental beam line is now under construction at Brookhaven National Laboratories Accelerator Test Facility (BNL/ATF) for photocathode RF gun testing and photoemission experiments. The design of the experimental line, using the 1.6 cell photocathode RF gun developed by the BNL/SLAC/UCLA RF gun collaboration is presented. Detailed beam dynamics simulations were performed for the 1.6 cell RF gun injector using a solenoidal emittance compensation technique. An experimental program for testing the 1.6 cell RF gun is presented. This program includes beam loading caused by dark current, higher order mode field measurements, integrated and slice emittance measurements using a pepper-pot and RF kicker cavity

  19. Cu2O/CuO Bilayered Composite as a High-Efficiency Photocathode for Photoelectrochemical Hydrogen Evolution Reaction

    Science.gov (United States)

    Yang, Yang; Xu, Di; Wu, Qingyong; Diao, Peng

    2016-10-01

    Solar powered hydrogen evolution reaction (HER) is one of the key reactions in solar-to-chemical energy conversion. It is desirable to develop photocathodic materials that exhibit high activity toward photoelectrochemical (PEC) HER at more positive potentials because a higher potential means a lower overpotential for HER. In this work, the Cu2O/CuO bilayered composites were prepared by a facile method that involved an electrodeposition and a subsequent thermal oxidation. The resulting Cu2O/CuO bilayered composites exhibited a surprisingly high activity and good stability toward PEC HER, expecially at high potentials in alkaline solution. The photocurrent density for HER was 3.15 mA·cm-2 at the potential of 0.40 V vs. RHE, which was one of the two highest reported at the same potential on copper-oxide-based photocathode. The high photoactivity of the bilayered composite was ascribed to the following three advantages of the Cu2O/CuO heterojunction: (1) the broadened light absorption band that made more efficient use of solar energy, (2) the large space-charge-region potential that enabled a high efficiency for electron-hole separation, and (3) the high majority carrier density that ensured a faster charge transportation rate. This work reveals the potential of the Cu2O/CuO bilayered composite as a promising photocathodic material for solar water splitting.

  20. Hydrogen Production Using a Molybdenum Sulfide Catalyst on a Titanium-Protected n+p-Silicon Photocathode

    DEFF Research Database (Denmark)

    Seger, Brian; Laursen, Anders Bo; Vesborg, Peter Christian Kjærgaard

    2012-01-01

    A low-cost substitute: A titanium protection layer on silicon made it possible to use silicon under highly oxidizing conditions without oxidation of the silicon. Molybdenum sulfide was electrodeposited on the Ti-protected n+p-silicon electrode. This electrode was applied as a photocathode for wat...

  1. Positron lifetime studies of 100-MeV oxygen irradiated Pb-doped Bi-2223 superconductors

    NARCIS (Netherlands)

    Banerjee, T.; Viswanath, R.N.; Kanjilal, D.; Kumar, R.; Ramasamy, S.

    2000-01-01

    Positron lifetime studies have been carried out for unirradiated and 100-MeV oxygen ion irradiated Pb-doped Bi-2223 superconductors. The analysis of positron lifetime spectra revealed three lifetime components: a short lifetime, τ1 = 153–196 ps; an intermediate lifetime, τ2 = 269–339 ps; and a long

  2. Enhanced photocathodic protection performance of Ag/graphene/TiO2 composite for 304SS under visible light

    Science.gov (United States)

    Li, Hong; Wang, Xiutong; Wei, Qinyi; Liu, Xueqing; Qian, Zhouhai; Hou, Baorong

    2017-06-01

    Ag and graphene co-sensitized TiO2 composites were successfully fabricated and used as photoanodes for photogenerated cathodic protection of 304 stainless steel (304SS) under visible light. Graphene films was firstly deposited onto the TiO2 nanotube (NT) films via cyclic voltammetric electrodeposition. Ag/graphene/TiO2 films were then fabricated via dipping and photoreduction method. The morphology, composition and optical response of the Ag/graphene/TiO2 NT composites were characterized by scanning electron microscopy, x-ray diffraction, x-ray photoelectron spectroscopy, UV-vis diffusion reflectance spectroscopy, respectively. The photocathodic protection performance of the Ag/graphene/TiO2 composites were systematically studied through open-circuit potential and potentiodynamic polarization measurements in 3.5 wt% NaCl solution under visible light (λ > 400 nm). The composites exhibited enhanced photogenerated cathodic protection performance for 304SS under visible light irradiation compared to pure TiO2. Graphene and Ag have a synergistic effect on the enhancement of photocathodic protection performance of TiO2. The composites prepared with 30-cycle graphene film and 15 mM AgNO3 solution showed the optimal corrosion protection performance.

  3. Formation and acceleration of uniformly filled ellipsoidal electron bunches obtained via space-charge-driven expansion from a cesium-telluride photocathode

    Directory of Open Access Journals (Sweden)

    P. Piot

    2013-01-01

    Full Text Available We report the experimental generation, acceleration, and characterization of a uniformly filled electron bunch obtained via space-charge-driven expansion (often referred to as “blow-out regime” in an L-band (1.3-GHz radiofrequency photoinjector. The beam is photoemitted from a cesium-telluride semiconductor photocathode using a short (<200  fs ultraviolet laser pulse. The produced electron bunches are characterized with conventional diagnostics and the signatures of their ellipsoidal character are observed. We especially demonstrate the production of ellipsoidal bunches with charges up to ∼0.5  nC corresponding to a ∼20-fold increase compared to previous experiments with metallic photocathodes.

  4. Study on lifetime of C stripping foils

    International Nuclear Information System (INIS)

    Zhang Hongbin; Lu Ziwei; Zhao Yongtao; Li Zhankui; Xu Hushan; Xiao Guoqing; Wang Yuyu; Zhang Ling; Li Longcai; Fang Yan

    2007-01-01

    The carbon stripping foils can be prepared with the AC and DC arc discharge methods, or even sandwiched with AC-DC alternative layers. The lifetime of the carbon stripping foils of 19 μg/cm 2 prepared with different methods and/or structures was measured. The factors affecting the bombarding lifetime of the carbon stripping foils, especially the method of the foil preparation and the structure of the carbon stripping foils, were discussed. It is observed that the foils prepared with the DC arc discharge method have a longer bombarding lifetime than those prepared with the AC arc discharge method. (authors)

  5. Positron annihilation lifetime study of oxide dispersion strengthened steels

    International Nuclear Information System (INIS)

    Krsjak, V.; Szaraz, Z.; Hähner, P.

    2012-01-01

    A comparative positron annihilation lifetime study has been performed on various commercial ferritic and ferritic/martensitic oxide dispersion strengthened (ODS) steels. Both as-extruded and recrystallized materials were investigated. In the materials with recrystallized coarse-grained microstructures, only the positron trapping at small vacancy clusters and yttria nanofeatures was observed. Materials which had not undergone recrystallization treatment clearly showed additional positron trapping which is associated with dislocations. Dislocation densities were calculated from a two-component decomposition of the positron lifetime spectra by assuming the first component to be a superposition of the bulk controlled annihilation rate and the dislocation controlled trapping rate. The second component (which translates into lifetimes of 240–260 ps) was found to be well separated in all those ODS materials. This paper presents the potentialities and limitations of the positron annihilation lifetime spectroscopy, and discusses the results of the experimental determination of the defect concentrations and sensitivity of this technique to the material degradation due to thermally induced precipitation of chromium-rich α′ phases.

  6. Surface-plasmon enhanced photoemission of a silver nano-patterned photocathode

    Science.gov (United States)

    Zhang, Z.; Li, R.; To, H.; Andonian, G.; Pirez, E.; Meade, D.; Maxson, J.; Musumeci, P.

    2017-09-01

    Nano-patterned photocathodes (NPC) take advantage of plasmonic effects to resonantly increase absorption of light and localize electromagnetic field intensity on metal surfaces leading to surface-plasmon enhanced photoemission. In this paper, we report the status of NPC research at UCLA including in particular the optimization of the dimensions of a nanohole array on a silver wafer to enhance plasmonic response at 800 nm light, the development of a spectrally-resolved reflectivity measurement setup for quick nanopattern validation, and of a novel cathode plug to enable high power tests of NPCs on single crystal substrates in a high gradient radiofrequency gun.

  7. Studies of Lifetimes in an Ion Storage Ring Using Laser Technique

    International Nuclear Information System (INIS)

    Rostohar, Danijela; Derkatch, Anna; Hartman, Henrik; Norlin, Lars-Olov; Royen, Peder; Schef, Peter; Mannervik, Sven

    2003-01-01

    The laser-probing method for lifetime measurements of metastable levels, performed by applying the Fast Ion Beam Laser (FIBLAS) method to ions stored in a storage ring, has been developed by the Stockholm group. Recently, we have applied this method to lifetime measurements of close lying metastable levels. In this paper we discuss experimental studies of ions with complex structure and present the first experimentally obtained lifetimes of selected metastable levels in complex systems as Fe + , Eu + and La + .

  8. A fast position sensitive photodetector based on a CsI reflective photocathode

    International Nuclear Information System (INIS)

    Arnold, R.; Christophel, E.; Guyonnet, J.L.

    1991-01-01

    A fast detector was built for UV photon detection that depends on a CsI sensitized pad cathode. The rapidity of the detector is compared with that of a more classical chamber filled with photosensitive gases such as TEA or TMAE. Estimates of the quantum yield of the photocathode at 160 and 200 nm are given. The performances obtained make it a good photodetector candidate to be operated at high luminosity accelerators. (author) 7 refs., 19 figs

  9. Understanding the prevalence of lifetime abstinence from alcohol: An ecological study.

    Science.gov (United States)

    Probst, Charlotte; Manthey, Jakob; Rehm, Jürgen

    2017-09-01

    The level of alcohol consumption and related burden in a country are strongly impacted by the prevalence of abstinence from alcohol use. The objective of this study was to characterize the association of lifetime abstinence from alcohol use with economic wealth (as measured in the gross domestic product [GDP]) and Muslim religion on a country level. An ecological study was performed using aggregate data of 183 countries for the year 2010. Lifetime abstinence among men and women was predicted using fractional response regression models with the natural logarithm of GDP-PPP (purchasing power parity) and the proportion of Muslim population as predictors. The models were further adjusted by the country's median age and World Health Organization region. Precision of prediction was investigated. Descriptive analyses showed a strong negative association between GDP-PPP and lifetime abstinence in countries without a Muslim majority and a GDP-PPP up to 20,000 international dollars. Regression models confirmed the negative association with GDP-PPP and showed a strong positive association between lifetime abstinence and the proportion of Muslim population. Stratified sensitivity analyses showed that in countries without a Muslim majority only GDP-PPP showed a statistically significant association whereas in Muslim majority countries only the proportion of Muslims was associated with the prevalence of lifetime abstinence. Particularly in countries with a lower GDP and without Muslim majority the prevalence of lifetime abstinence from alcohol use is strongly negatively associated with GDP-PPP. Future research should analyze the accordance in trends of GDP and lifetime abstinence over time. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Minority Carrier Lifetime Studies of Narrow Bandgap Antimonide Superlattices

    Science.gov (United States)

    Hoglund, Linda; Ting, David Z.; Khoshakhlagh, Arezou; Soibel, Alexander; Hill, Cory J.; Fisher, Anita; Keo, Sam; Gunapala, Sarath D.

    2014-01-01

    In this study optical modulation response and photoluminescence spectroscopy were used to study mid-wave Ga-free InAs/InAsSb superlattices. The minority carrier lifetimes in the different samples varied from 480 ns to 4700 ns, partly due to different background doping concentrations. It was shown that the photoluminescence intensity can be used as a fast non-destructive tool to predict the material quality. It was also demonstrated that it is crucial to use a low excitation power in the photoluminescence measurements in order to get a good correlation between the photoluminescence intensity and the minority carrier lifetime.

  11. Positron lifetime study of copper irradiated by energetic protons or energetic neutrons

    International Nuclear Information System (INIS)

    Howell, R.H.

    1979-03-01

    Positron lifetime measurements of pure copper damaged by irradiation with energetic protons and neutrons are presented. Lifetime determinations of the bulk material and various traps were made, and the dependence of the trapping rate on dose and irradiation energy were investigated. The results from the neutron- and proton-irradiated samples point to the existence of traps with similar but distinct lifetime parameters, not varying greatly from values reported in deformation studies. Also, a trap with long lifetime is seen for some proton irradiations, but is never seen for the neutron irradiations. The trapping rate of the short-lifetime trap is a linear function of dose for proton-irradiated samples and nearly so for the neutron irradiation. 1 figure

  12. Effect of annealing process on the heterostructure CuO/Cu2O as a highly efficient photocathode for photoelectrochemical water reduction

    Science.gov (United States)

    Du, Fan; Chen, Qing-Yun; Wang, Yun-Hai

    2017-05-01

    CuO/Cu2O photocathodes were successfully prepared via simply annealing the electrodeposited Cu2O on fluoride doped tin oxide (FTO) substrate. They were characterized by X-ray diffraction, scanning electron microscopy (SEM), transmission electron microscope (TEM), UV-vis absorption spectra and X-ray photoelectron spectroscopy (XPS). The results showed that the heterojunction of CuO/Cu2O was formed during the annealing process and presented the nature of p-type semiconductor. The photocurrent density and photoelectrochemical (PEC) stability of the p-type heterostructure CuO/Cu2O photocathode was improved greatly compared with the pure Cu2O, which was greatly affected by annealing time and temperature. The highest photo current density of -0.451 mA/cm2 and highest stability was obtained via annealing at 650 °C for 15 min (at -0.3 V vs. Ag/AgCl), which gave a remarkable improvement than the as-deposited Cu2O (-0.08 mA/cm2). This suggested that the CuO/Cu2O heterojunction facilitated the electron-hole pair separation and improved the photocathode's current and stability.

  13. Experimental studies of emittance growth and energy spread in a photocathode RF gun

    International Nuclear Information System (INIS)

    Yang, J.; Sakai, F.; Okada, Y.; Yorozu, M.; Yanagida, T.; Endo, A.

    2002-01-01

    In this paper we report on a low emittance electron source, based on a photocathode RF gun, a solenoid magnet and a subsequent linac. The dependencies of the beam transverse emittance and relative energy spread with respect to the laser injection phase of the radio-frequency (RF) gun, the RF phase of the linac and the bunch charge were investigated experimentally. It was found that a lower beam emittance is observed when the laser injection phase in the RF gun is low. The emittance increases almost linearly with the bunch charge under a constant solenoid magnetic field. The corrected relative energy spread of the beam is not strongly dependent on the bunch charge. Finally, an optimal normalized rms transverse emittance of 1.91±0.28 πmm mrad at a bunch charge of 0.6 nC was obtained when the RF gun was driven by a picosecond Nd:YAG laser. A corrected relative rms energy spread of 0.2-0.25% at a bunch charge of 0.3-2 nC was obtained after the beam was accelerated to 14 MeV by the subsequent linac

  14. Experimental studies of emittance growth and energy spread in a photocathode RF gun

    CERN Document Server

    Yang, J; Okada, Y; Yorozu, M; Yanagida, T; Endo, A

    2002-01-01

    In this paper we report on a low emittance electron source, based on a photocathode RF gun, a solenoid magnet and a subsequent linac. The dependencies of the beam transverse emittance and relative energy spread with respect to the laser injection phase of the radio-frequency (RF) gun, the RF phase of the linac and the bunch charge were investigated experimentally. It was found that a lower beam emittance is observed when the laser injection phase in the RF gun is low. The emittance increases almost linearly with the bunch charge under a constant solenoid magnetic field. The corrected relative energy spread of the beam is not strongly dependent on the bunch charge. Finally, an optimal normalized rms transverse emittance of 1.91+-0.28 pi mm mrad at a bunch charge of 0.6 nC was obtained when the RF gun was driven by a picosecond Nd:YAG laser. A corrected relative rms energy spread of 0.2-0.25% at a bunch charge of 0.3-2 nC was obtained after the beam was accelerated to 14 MeV by the subsequent linac.

  15. High power beam test and measurement of emittance evolution of a 1.6-cell photocathode RF gun at Pohang Accelerator Laboratory

    International Nuclear Information System (INIS)

    Park, Jang-Ho; Park, Sung-Ju; Kim, Changbum; Huang, Jung-Yun; Ko, In Soo; Parc, Yong-Woon; Hong, Ju-Ho; Xiang Dao; Wang, Xijie

    2007-01-01

    A Brookhaven National Laboratory (BNL) GUN-IV type photocathode rf gun has been fabricated to use in femtosecond electron diffraction (FED), femtosecond far infrared radiation (fs-FIR) facility, and X-ray free electron laser (XFEL) facilities at the Pohang Accelerator Laboratory (PAL). The gun consists of a 1.6-cell cavity with a copper cathode, a solenoid magnet, beam diagnostic components and auxiliary systems. We report here the measurement of the basic beam parameters which confirm a successful fabrication of the photocathode RF gun system. The emittance evolution is measured by an emittance meter and compared with the PARMELA simulation, which shows a good agreement. (author)

  16. Photomultiplier characteristics considerations for the deep underwater muon and neutrino detection system

    International Nuclear Information System (INIS)

    Leskovar, B.

    1980-01-01

    The results of an investigation of the characteristics of photomultipliers for the Deep Underwater Muon and Neutrino Detection (DUMAND) System are discussed. The pulse-height resolution, the afterpulsing phenomena and the gain sensitivity to the ambient magnetic field have been determined for large photocathode area photomultipliers. Furthermore, the transient time difference, the single photoelectron time spread, and the collection and photocathode quantum efficiency uniformity as a function of the position of the photocathode sensing area have been reviewed. Finally, an attempt has been made to estimate the photomultiplier reliability and its lifetime

  17. Hydrogen and electricity production in a light-assisted microbial photoelectrochemical cell with CaFe2O4 photocathode

    Science.gov (United States)

    Chen, Qing-Yun; Zhang, Kai; Liu, Jian-Shan; Wang, Yun-Hai

    2017-04-01

    A microbial photoelectrochemical cell (MPEC) was designed with a p-type CaFe2O4 semiconductor as the photoelectrode for simultaneous hydrogen and electricity production under light illumination. The CaFe2O4 photoelectrode was synthesized by the sol-gel method and well characterized by x-ray diffraction, field emission scanning electron microscope, and UV-Vis-NIR spectrophotometer. The linear sweep voltammogram of the CaFe2O4 photoelectrode presented the cathodic photocurrent output. For the MPEC, with an external resistance of 2000 Ω, the maximum power density of 143 mW was obtained. Furthermore, with an external resistance of 100 Ω, the maximum hydrogen production rate of 6.7 μL·cm-2 could be achieved. The MPEC with CaFe2O4 photocathode was compared to MPEC with other photocathodes as well as photocatalytic water splitting technology.

  18. New Antimony Selenide/Nickel Oxide Photocathode Boosts the Efficiency of Graphene Quantum-Dot Co-Sensitized Solar Cells.

    Science.gov (United States)

    Kolay, Ankita; Kokal, Ramesh K; Kalluri, Ankarao; Macwan, Isaac; Patra, Prabir K; Ghosal, Partha; Deepa, Melepurath

    2017-10-11

    A novel assembly of a photocathode and a photoanode is investigated to explore their complementary effects in enhancing the photovoltaic performance of a quantum-dot solar cell (QDSC). While p-type nickel oxide (NiO) has been used previously, antimony selenide (Sb 2 Se 3 ) has not been used in a QDSC, especially as a component of a counter electrode (CE) architecture that doubles as the photocathode. Here, near-infrared (NIR) light-absorbing Sb 2 Se 3 nanoparticles (NPs) coated over electrodeposited NiO nanofibers on a carbon (C) fabric substrate was employed as the highly efficient photocathode. Quasi-spherical Sb 2 Se 3 NPs, with a band gap of 1.13 eV, upon illumination, release photoexcited electrons in addition to other charge carriers at the CE to further enhance the reduction of the oxidized polysulfide. The p-type conducting behavior of Sb 2 Se 3 , coupled with a work function at 4.63 eV, also facilitates electron injection to polysulfide. The effect of graphene quantum dots (GQDs) as co-sensitizers as well as electron conduits is also investigated in which a TiO 2 /CdS/GQDs photoanode structure in combination with a C-fabric CE delivered a power-conversion efficiency (PCE) of 5.28%, which is a vast improvement over the 4.23% that is obtained by using a TiO 2 /CdS photoanode (without GQDs) with the same CE. GQDs, due to a superior conductance, impact efficiency more than Sb 2 Se 3 NPs do. The best PCE of a TiO 2 /CdS/GQDs-nS 2- /S n 2- -Sb 2 Se 3 /NiO/C-fabric cell is 5.96% (0.11 cm 2 area), which, when replicated on a smaller area of 0.06 cm 2 , is seen to increase dramatically to 7.19%. The cell is also tested for 6 h of continuous irradiance. The rationalization for the channelized photogenerated electron movement, which augments the cell performance, is furnished in detail in these studies.

  19. Experimental measurements and theoretical model of the cryogenic performance of bialkali photocathode and characterization with Monte Carlo simulation

    Directory of Open Access Journals (Sweden)

    Huamu Xie

    2016-10-01

    Full Text Available High-average-current, high-brightness electron sources have important applications, such as in high-repetition-rate free-electron lasers, or in the electron cooling of hadrons. Bialkali photocathodes are promising high-quantum-efficiency (QE cathode materials, while superconducting rf (SRF electron guns offer continuous-mode operation at high acceleration, as is needed for high-brightness electron sources. Thus, we must have a comprehensive understanding of the performance of bialkali photocathode at cryogenic temperatures when they are to be used in SRF guns. To remove the heat produced by the radio-frequency field in these guns, the cathode should be cooled to cryogenic temperatures. We recorded an 80% reduction of the QE upon cooling the K_{2}CsSb cathode from room temperature down to the temperature of liquid nitrogen in Brookhaven National Laboratory (BNL’s 704 MHz SRF gun. We conducted several experiments to identify the underlying mechanism in this reduction. The change in the spectral response of the bialkali photocathode, when cooled from room temperature (300 K to 166 K, suggests that a change in the ionization energy (defined as the energy gap from the top of the valence band to vacuum level is the main reason for this reduction. We developed an analytical model of the process, based on Spicer’s three-step model. The change in ionization energy, with falling temperature, gives a simplified description of the QE’s temperature dependence. We also developed a 2D Monte Carlo code to simulate photoemission that accounts for the wavelength-dependent photon absorption in the first step, the scattering and diffusion in the second step, and the momentum conservation in the emission step. From this simulation, we established a correlation between ionization energy and reduction in the QE. The simulation yielded results comparable to those from the analytical model. The simulation offers us additional capabilities such as calculation

  20. High-power fiber lasers for photocathode electron injectors

    Directory of Open Access Journals (Sweden)

    Zhi Zhao

    2014-05-01

    Full Text Available Many new applications for electron accelerators require high-brightness, high-average power beams, and most rely on photocathode-based electron injectors as a source of electrons. To achieve such a photoinjector, one requires both a high-power laser system to produce the high average current beam, and also a system at reduced repetition rate for electron beam diagnostics to verify high beam brightness. Here we report on two fiber laser systems designed to meet these specific needs, at 50 MHz and 1.3 GHz repetition rate, together with pulse pickers, second harmonic generation, spatiotemporal beam shaping, intensity feedback, and laser beam transport. The performance and flexibility of these laser systems have allowed us to demonstrate electron beam with both low emittance and high average current for the Cornell energy recovery linac.

  1. Positron annihilation lifetime study of radiation-damaged natural zircons

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, J. [Centre for Antimatter-Matter Studies, Research School of Physics and Engineering, The Australian National University, Canberra (Australia); Gaugliardo, P. [Centre for Antimatter-Matter Studies, School of Physics, University of Western Australia (Australia); Farnan, I.; Zhang, M. [Department of Earth Sciences, University of Cambridge (United Kingdom); Vance, E.R.; Davis, J.; Karatchevtseva, I.; Knott, R.B. [Australian Nuclear Science and Technology Organisation (Australia); Mudie, S. [The Australian Synchrotron, Victoria (Australia); Buckman, S.J. [Centre for Antimatter-Matter Studies, Research School of Physics and Engineering, The Australian National University, Canberra (Australia); Institute for Mathematical Sciences, University of Malaya, Kuala Lumpur (Malaysia); Sullivan, J.P., E-mail: james.sullivan@anu.edu.au [Centre for Antimatter-Matter Studies, Research School of Physics and Engineering, The Australian National University, Canberra (Australia)

    2016-04-01

    Zircons are a well-known candidate waste form for actinides and their radiation damage behaviour has been widely studied by a range of techniques. In this study, well-characterised natural single crystal zircons have been studied using Positron Annihilation Lifetime Spectroscopy (PALS). In some, but not all, of the crystals that had incurred at least half of the alpha-event damage of ∼10{sup 19} α/g required to render them structurally amorphous, PALS spectra displayed long lifetimes corresponding to voids of ∼0.5 nm in diameter. The long lifetimes corresponded to expectations from published Small-Angle X-ray Scattering data on similar samples. However, the non-observation by PALS of such voids in some of the heavily damaged samples may reflect large size variations among the voids such that no singular size can be distinguished or. Characterisation of a range of samples was also performed using scanning electron microscopy, optical absorption spectroscopy, Raman scattering and X-ray scattering/diffraction, with the degree of alpha damage being inferred mainly from the Raman technique and X-ray diffraction. The observed void diameters and intensities of the long lifetime components were changed somewhat by annealing at 700 °C; annealing at 1200 °C removed the voids entirely. The voids themselves may derive from He gas bubbles or voids created by the inclusion of small quantities of organic and hydrous matter, notwithstanding the observation that no voidage was evidenced by PALS in two samples containing hydrous and organic matter. - Highlights: • Study of a range of naturally occurring zircons damaged by alpha radiation. • Characterised using a range of techniques, including PALS spectroscopy. • Effects on hydrous material appear important, rather than direct radiation damage. • Annealing is shown to remove the observed voids.

  2. Comparison of the performance of cop-coated and pt-coated radial junction n+p-silicon microwire-array photocathodes for the sunlight-driven reduction of water to H2(g)

    DEFF Research Database (Denmark)

    Roske, Christopher W.; Popczun, Eric J.; Seger, Brian

    2015-01-01

    -array photocathodes produced Voc = 0.44 V, Jph = 14 mA cm-2, ff = 0.46, and η = 2.9% under identical conditions. Thus, the MW geometry allows the fabrication of photocathodes entirely comprised of earth-abundant materials that exhibit performance comparable to that of devices that contain Pt....

  3. Positron annihilation lifetime and photoluminescence studies on single crystalline ZnO

    Energy Technology Data Exchange (ETDEWEB)

    Sarkar, A [Department of Physics, Bangabasi Morning College, 19 Rajkumar Chakraborty Sarani, Kolkata 700 009 (India); Chakrabarti, Mahuya [Department of Physics, University of Calcutta, 92 Acharya Prafulla Chandra Road, Kolkata 700009 (India); Ray, S K [Department of Physics and Meteorology, Indian Institute of Technology, Kharagpur (India); Bhowmick, D; Sanyal, D, E-mail: dirtha@vecc.gov.in [Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064 (India)

    2011-04-20

    The room temperature positron annihilation lifetime for single crystalline ZnO has been measured as 164 {+-} 1 ps. The single component lifetime value is very close to but higher than the theoretically predicted value of {approx} 154 ps. Photoluminescence study (at 10 K) indicates the presence of hydrogen and other defects, mainly acceptor related, in the crystal. Defects related to a lower open volume than zinc vacancies, presumably a complex with two hydrogen atoms, are the major trapping sites in the sample. The bulk positron lifetime in ZnO is expected to be a little less than 164 ps.

  4. Positron annihilation lifetime and photoluminescence studies on single crystalline ZnO

    Science.gov (United States)

    Sarkar, A.; Chakrabarti, Mahuya; Ray, S. K.; Bhowmick, D.; Sanyal, D.

    2011-04-01

    The room temperature positron annihilation lifetime for single crystalline ZnO has been measured as 164 ± 1 ps. The single component lifetime value is very close to but higher than the theoretically predicted value of ~ 154 ps. Photoluminescence study (at 10 K) indicates the presence of hydrogen and other defects, mainly acceptor related, in the crystal. Defects related to a lower open volume than zinc vacancies, presumably a complex with two hydrogen atoms, are the major trapping sites in the sample. The bulk positron lifetime in ZnO is expected to be a little less than 164 ps.

  5. Positron annihilation lifetime and photoluminescence studies on single crystalline ZnO

    International Nuclear Information System (INIS)

    Sarkar, A; Chakrabarti, Mahuya; Ray, S K; Bhowmick, D; Sanyal, D

    2011-01-01

    The room temperature positron annihilation lifetime for single crystalline ZnO has been measured as 164 ± 1 ps. The single component lifetime value is very close to but higher than the theoretically predicted value of ∼ 154 ps. Photoluminescence study (at 10 K) indicates the presence of hydrogen and other defects, mainly acceptor related, in the crystal. Defects related to a lower open volume than zinc vacancies, presumably a complex with two hydrogen atoms, are the major trapping sites in the sample. The bulk positron lifetime in ZnO is expected to be a little less than 164 ps.

  6. Lifetime costs of cerebral palsy

    DEFF Research Database (Denmark)

    Kruse, Marie; Michelsen, Susan Ishøy; Flachs, Esben Meulengracht

    2009-01-01

    This study quantified the lifetime costs of cerebral palsy (CP) in a register-based setting. It was the first study outside the US to assess the lifetime costs of CP. The lifetime costs attributable to CP were divided into three categories: health care costs, productivity costs, and social costs....... social care costs and productivity costs associated with CP point to a potential gain from labour market interventions that benefit individuals with CP.......This study quantified the lifetime costs of cerebral palsy (CP) in a register-based setting. It was the first study outside the US to assess the lifetime costs of CP. The lifetime costs attributable to CP were divided into three categories: health care costs, productivity costs, and social costs...... in 2000. The prevalence of CP in eastern Denmark was approximately 1.7 per 1000. Information on productivity and the use of health care was retrieved from registers. The lifetime cost of CP was about euro860 000 for men and about euro800 000 for women. The largest component was social care costs...

  7. A photocathode rf gun design for a mm-wave linac-based FEL

    Energy Technology Data Exchange (ETDEWEB)

    Nassiri, A.; Berenc, T,; Foster, J.; Waldschmidt, G.; Zhou, J.

    1995-07-01

    In recent years, advances in the rf gun technology have made it possible to produce small beam emittances suitable for short period microundulators which take advantage of the low emittance beam to reduce the wavelength of FELs. At the Advanced Photon Source, we are studying the design of a compact 50-MeV superconducting mm-wave linac-based FEL for the production of short wavelengths ({approximately}300 nm) to carry out FEL demonstration experiments. The electron source considered for the linac is a 30- GHz, 3 1/2-cell {pi}-mode photocathode rf gun. For cold model rf measurements a 15-GHz prototype structure was fabricated. Here we report on the design, numerical modelling and the initial cold-model rf measurement results on the 15-GHz prototype structure.

  8. A photocathode rf gun design for a mm-wave linac-based FEL

    International Nuclear Information System (INIS)

    Nassiri, A.; Berenc, T.; Foster, J.; Waldschmidt, G.; Zhou, J.

    1995-01-01

    In recent years, advances in the rf gun technology have made it possible to produce small beam emittances suitable for short period microundulators which take advantage of the low emittance beam to reduce the wavelength of FELs. At the Advanced Photon Source, we are studying the design of a compact 50-MeV superconducting mm-wave linac-based FEL for the production of short wavelengths (∼300 nm) to carry out FEL demonstration experiments. The electron source considered for the linac is a 30- GHz, 3 1/2-cell π-mode photocathode rf gun. For cold model rf measurements a 15-GHz prototype structure was fabricated. Here we report on the design, numerical modelling and the initial cold-model rf measurement results on the 15-GHz prototype structure

  9. Reactive magnetron sputtering of N-doped carbon thin films on quartz glass for transmission photocathode applications

    Science.gov (United States)

    Balalykin, N. I.; Huran, J.; Nozdrin, M. A.; Feshchenko, A. A.; Kobzev, A. P.; Sasinková, V.; Boháček, P.; Arbet, J.

    2018-03-01

    N-doped carbon thin films were deposited on a silicon substrate and quartz glass by RF reactive magnetron sputtering using a carbon target and an Ar+N2 gas mixture. During the magnetron sputtering, the substrate holder temperatures was kept at 800 °C. The carbon film thickness on the silicon substrate was about 70 nm, while on the quartz glass it was in the range 15 nm – 60 nm. The elemental concentration in the films was determined by RBS and ERD. Raman spectroscopy was used to evaluate the intensity ratios I D/I G of the D and G peaks of the carbon films. The transmission photocathodes prepared were placed in the hollow-cathode assembly of a Pierce-structure DC gun to produce photoelectrons. The quantum efficiency (QE) was calculated from the laser energy and cathode charge measured. The properties of the transmission photocathodes based on semitransparent N-doped carbon thin films on quartz glass and their potential for application in DC gun technology are discussed.

  10. High-charge s-band photocathode RF-gun and linac system for radiation research

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Tetsuya; Uesaka, Mitsuru; Katsumura, Yousuke [Univ. of Tokyo, Graduate School of Engineering, Nuclear Engineering Research Laboratory, Tokai, Ibaraki (JP)] (and others)

    2002-01-01

    For sub-picosecond pump-and-prove-type radiation chemistry work, a new synchronized electron linac and laser system was installed in the Nuclear Engineering Research Laboratory (NERL) of University of Tokyo. The new laser system, with a Ti:Sapphire oscillator (795 nm) and amplifiers, generates 300 ps pulses at 10 Hz. The laser is transported through the vacuum chamber and then split into two beams. The first is compressed and converted to the third harmonics (265 nm, <250 {mu}J, 4-11 ps) so as to drive the photocathode RF-gun and generate a pump-electron beam. The second is compressed to 100 fs and used for the probe light. The high-power RF, which is provided by a new 15 MW klystron, is divided into the gun and the accelerating section. Finally, a time jitter of 330 fs (rms) was achieved between the pump-electron beam and the probe laser, which is equivalent to the design value of 320 fs. A charge of 7 nC/bunch was observed at the exit of the gun from this new laser system. Improvement of the vacuum in the gun (<10{sup -9} Torr) is the most effective way to obtain such a high-charge beam. After about three years of operation, the Cu photocathode has shown no degradation of quantum efficiency. (author)

  11. Study of straw chamber lifetime with argon ethane

    International Nuclear Information System (INIS)

    Adler, J.; Bolton, T.; Bunnell, K.; Cheu, E.; Grab, C.; Mazaheri, G.; Odian, A.; Pitman, D.; Stockhausen, W.; Toki, W.; Wadley, W.; Wood, C.; Mir, R.

    1989-01-01

    We present detailed laboratory measurements of the lifetime of a small test chamber, simulating the Mark III straw vertex chamber conditions. The tests were carried out with an argon-ethane 50/50 gas mixture at 3 atm absolute pressure and 3.9 kV applied to the wires. After the accumulation of ≅ 0.02 C/cm on a single straw, continuous discharges began. The addition of alcohol or water vapor to the gas mixture was found to extend the lifetime of the straws. Continuous flow of the gas mixture with water vapor through the straws prolonged the lifetime significantly. We present results on the effects of changing the gas mixture inside the straws at regular time intervals. Adding a small percentage of water vapor to the argon-ethane gas and flowing the gas mixture in the straws can improve the lifetime by more than an order of magnitude. An accumulated charge of 1.0 C/cm on a single straw has been obtained. (orig.)

  12. Lifetime-management and lifetime-extension at PAKS nuclear power plant

    International Nuclear Information System (INIS)

    Katona, Tamas; Ratkai, Sandor; Janosi, Agnes Biro

    2002-01-01

    Paks Nuclear Power Plant provides 38-40% of domestic generation at lowest price. It has an important energy-policy role in Hungary. NPP Paks shall be a decisive and perspectively permanent element of the domestic electricity generation during the next two decades, which shall be ensured by plant safe operation, the lifetime extension and power uprating. Paks Nuclear Power Plant investigated the nuclear power plant's lifetime extension possibilities and alternatives, as well as technical and business feasibility of such alternatives. The feasibility study is based on the evaluation of a representative set of systems, structures and components, operational, test, in-service inspection and maintenance practice, experience and findings of the Periodic Safety Review. The most important results of this study showing the feasibility of 20 years lifetime extension is summarised in the paper. It was found that there are no technical or safety issues or limits, which may inhibit the operation of the Nuclear Power Plant Paks up to 50 years. In case of most systems and equipment the recent monitoring, maintenance and regular reconstruction practice of the NPP Paks allows the lifetime extension without outstanding cost. Replacement or reconstruction of a few equipment and systems requires significant investment costs. Material of reactor vessels of VVER/213 incorporated at Paks, compared to vessels of the similar units, is less sensitive to the embrittlement. At units 3-4 reactor vessels do not require any measure, consequently, any additional cost, even in case of a lifetime of 50 years. At unit 2 to extend the lifetime of the reactor vessel, only heating-up of emergency core cooling tanks is needed in order to decrease thermal stress levels caused by pressure thermal shock (PST) transients. For this purpose cost-effective technical solutions are available. At unit 1, beside the heating-up of the emergency core cooling tanks annealing of the welded joint No. 5/6 close to the

  13. Study on Effect of Junction Temperature Swing Duration on Lifetime of Transfer Molded Power IGBT Modules

    DEFF Research Database (Denmark)

    Choi, Uimin; Blaabjerg, Frede; Jørgensen, Søren

    2017-01-01

    levels are presented. This study enables to include the tΔTj effect on lifetime model of IGBT modules for its lifetime estimation and it may result in improved lifetime prediction of IGBT modules under given mission profiles of converters. A postfailure analysis of the tested IGBT modules is also......In this paper, the effect of junction temperature swing duration on lifetime of transfer molded power insulated gate bipolar transistor (IGBT) modules is studied and a relevant lifetime factor is modeled. This study is based on 39 accelerated power cycling test results under six different...

  14. Generation of quasiequally spaced ultrashort microbunches in a photocathode rf gun

    International Nuclear Information System (INIS)

    He, Zhigang; Xu, Yuanfang; Li, Weiwei; Jia, Qika

    2015-01-01

    A photocathode rf gun can generate trains of THz subpicosecond electron bunches by illuminating the cathode with trains of laser pulses, but it suffers from the increasing charge in the beam. The THz structure blurs and tends to disappear when the longitudinal space charge forces begin to play a significant role in the beam evolution. In this paper, we propose a scheme to restrain the space charge forces by expanding the transverse size of the laser pulses to reduce the charge density and adopting a multicell gun to increase the beam energy. Thus, quasiequally spaced ultrashort microbunches with relatively high charges can be generated according to our studies. Postacceleration can be used to freeze the longitudinal phase space dynamics. The proposed scheme is in principle able to generate intense multi-color narrow-band THz radiation and offers a promising way towards the tunable intense narrow-band THz sources

  15. Design of a high charge (10 - 100 nC) and short pulse (2 - 5 ps) rf photocathode gun for wakefield acceleration

    International Nuclear Information System (INIS)

    Gai, W.

    1998-01-01

    In this paper we present a design report on a 1-1/2 cell, L Band RF photocathode gun that is capable of generating and accelerating electron beams with peak currents >10 kA. We have performed simulation for bunch intensities in the range of 10-100 nC with peak axial electrical field at the photocathode of 30-100 MV/m. Unlike conventional short electron pulse generation, this design does not require magnetic pulse compression. Based on numerical simulations using SUPERFISH and PARMELA, this design will produce 20-100 nC beam at 18 MeV with rms bunch length 0.6-1.25 mm and normalized transverse emittance 30-108 mm mrad. Applications of this beam for wakefield acceleration is also discussed

  16. Positron annihilation lifetime study of low temperature irradiated metals

    Energy Technology Data Exchange (ETDEWEB)

    Kuramoto, Eiichi [Kyushu Univ., Kasuga, Fukuoka (Japan). Research Inst. for Applied Mechanics

    1997-11-01

    Positron annihilation lifetime measurements have been made for electron and neutron irradiated Fe, Fe-Cr, Fe-Cu, Fe-Si, Fe-16Cr-17Ni specimens, and isochronal annealing behaviors were obtained for these metals and alloys. It was found that vacancies start to migrate at about 200 K in Fe and form microvoids, but by the addition of small amount of alloying elements this behavior was changed depending on the alloying elements. Positron lifetime calculations were made to explain the experimental results using EAM (embedded atom method) type potential for the lattice relaxation and the atomic superposition method for the lifetime calculation. Fairly good agreements were obtained for the positron lifetime in a vacancy in Fe and other alloys. (author)

  17. Positron annihilation lifetime spectroscopy study of Kapton thin foils

    Science.gov (United States)

    Kanda, G. S.; Ravelli, L.; Löwe, B.; Egger, W.; Keeble, D. J.

    2016-01-01

    Variable energy positron annihilation lifetime spectroscopy (VE-PALS) experiments on polyimide material Kapton are reported. Thin Kapton foils are widely used in a variety of mechanical, electronic applications. PALS provides a sensitive probe of vacancy-related defects in a wide range of materials, including open volume in polymers. Varying the positron implantation energy enables direct measurement of thin foils. Thin Kapton foils are also commonly used to enclose the positron source material in conventional PALS measurements performed with unmoderated radionuclide sources. The results of depth-profiled positron lifetime measurements on 7.6 μm and 25 μm Kapton foils are reported and determine a dominant 385(1) ps lifetime component. The absence of significant nanosecond lifetime component due to positronium formation is confirmed.

  18. A high-gradient high-duty-factor Rf photo-cathode electron gun

    International Nuclear Information System (INIS)

    Rimmer, Robert A.; Hartman, Neal; Lidia, Steven M.; Wang, Shaoheng

    2002-01-01

    We describe the analysis and preliminary design of a high-gradient, high-duty factor RF photocathode gun. The gun is designed to operate at high repetition rate or CW, with high gradient on the cathode surface to minimize emittance growth due to space charge forces at high bunch charge. The gun may also be operated in a solenoidal magnetic field for emittance compensation. The design is intended for use in short-pulse, high-charge, and high-repetition rate applications such as linac based X-ray sources. We present and compare the results of gun simulations using different codes, as well as RF and thermal analysis of the structure

  19. A high-gradient high-duty-factor RF photo-cathode electron gun

    International Nuclear Information System (INIS)

    Rimmer, Robert; Hartman, N.; Lidia, S.; Wang, S.H.

    2002-01-01

    We describe the analysis and preliminary design of a high-gradient, high-duty factor RF photocathode gun. The gun is designed to operate at high repetition rate or CW, with high gradient on the cathode surface to minimize emittance growth due to space charge forces at high bunch charge. The gun may also be operated in a solenoidal magnetic field for emittance compensation. The design is intended for use in short-pulse, high-charge, and high-repetition rate applications such as linac based X-ray sources. We present and compare the results of gun simulations using different codes, as well as RF and thermal analysis of the structure

  20. Dynamic lifetimes of cagelike water clusters immersed in liquid water and their implications for hydrate nucleation studies

    Energy Technology Data Exchange (ETDEWEB)

    Guo, G.J.; Zhang, Y.G.; Li, M.; Wu, C.H. [Chinese Academy of Sciences, Inst. of Geology and Geophysics, Beijing (China). Key Laboratory of the Study of Earth' s Deep Interior

    2008-07-01

    In hydrate research fields, the hydrate nucleation mechanism still remains as an unsolved question. The static lifetimes of cagelike water clusters (CLWC) immersed in bulk liquid water have recently been measured by performing molecular dynamics simulations in the methane-water system, during which the member-water molecules of CLWCs are not allowed to exchange with their surrounding water molecules. This paper presented a study that measured the dynamic lifetimes of CLWCs permitting such water exchanges. The study involved re-analysis of previous simulation data that were used to study the effect of methane adsorption on the static lifetimes of a dodecahedral water cluster (DWC). The dynamic lifetimes of the DWC were calculated. The results of lifetime measurements of DWC in different systems were provided. The implications of this study for hydrate nucleation were also discussed. It was found that the dynamic lifetimes of CLWCs were not less than the static lifetimes previously obtained, and their ratio increased with the lifetime values. The results strengthened that CLWCs are metastable structures in liquid water and the occurrence probability of long-lived CLWCs will increase if one uses the dynamic lifetimes instead of the static lifetimes. 13 refs., 1 tab., 3 figs.

  1. Thin film studies toward improving the performance of accelerator electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Mamun, Md Abdullah [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Old Dominion Univ., Norfolk, VA (United States)

    2016-05-31

    the task of implementing photocathode cooling, which is required for future high current electron beam applications. The best performing TiN-coated aluminum electrode demonstrated less than 15 pA of field emission current at -- 175 kV for a 10 mm cathode/anode gap, which corresponds to a field strength of 22.5 MV/m. Third, the effect of antimony thickness on the performance of bialkali-antimonide photocathodes was studied. The high-capacity effusion source enabled us to successfully manufacture photocathodes having a maximum QE around 10% and extended low voltage 1/e lifetime (> 90 days) at 532 nm via the co-deposition method, with relatively thick layers of antimony (≥ 300 nm). We speculate that alkali co-deposition provides optimized stoichiometry for photocathodes manufactured using thick Sb layers, which could serve as a reservoir for the alkali. In summary, this research examined the effectiveness of thin films applied on photogun chamber components to achieve an extremely high vacuum, to eliminate high voltage induced field emission from electrodes, and to generate photocurrent with high quantum yield with an extended operational lifetime. Simultaneous implementation of these findings can meet the challenges of future ultra-bright photoguns.

  2. Lifetimes of heavy flavour particles

    International Nuclear Information System (INIS)

    Forty, R.

    1994-01-01

    The lifetimes of heavy-flavour hadrons are reviewed. After a brief discussion of the theoretical predictions, the problem of averaging lifetime measurements is discussed. The various experimental measurements are then presented and suitable averages performed. Charmed meson lifetimes are now measured to the few percent level, better that theory can predict, whilst for charmed baryons the lifetime hierarchy has been established for the first time. For beauty hadrons the lifetimes are measured at the 6-10 % level, and are in reasonable agreement with theoretical expectations. Beauty baryon studies ar just beginning. (author)

  3. Photoelectron extraction efficiency from a CsI photocathode and THGEM operation in He−CF4 and He−CH4 mixtures

    International Nuclear Information System (INIS)

    Coimbra, A.E.C.; Santos, J.M.F. dos; Israelashvili, I.

    2016-01-01

    This work presents the experimental measurements obtained for UV-induced photo-electron extraction efficiency from a CsI photocathode into He with CF 4 and CH 4 gas mixtures. A 1000Å CsI photocathode was deposited on a gold plated THGEM for photo-electron conversion. Charge-gain measurements were obtained with a Single-THGEM detector operating in these gas mixtures using a continuous UV lamp for the extraction of photo-electrons. Charge-gains in excess of 10 5 were obtained for gas mixtures containing percentages of quencher higher than 20% while photo-electron extraction efficiency achieved ∼ 50% for He/CF 4 and ∼ 30% for He/CH 4 . Single photon electron measurements were also performed to assess the maximal gains reached in this regime. A discussion for future GPM cryogenic applications is presented

  4. 3D ZnIn2S4 nanosheet/TiO2 nanowire arrays and their efficient photocathodic protection for 304 stainless steel

    Science.gov (United States)

    Sun, Wenxia; Wei, Na; Cui, Hongzhi; Lin, Yuan; Wang, Xinzhen; Tian, Jian; Li, Jian; Wen, Jing

    2018-03-01

    A well-designed heterostructure engineered ZnIn2S4 nanosheet/TiO2 nanowire arrays photoanode is investigated for photocathodic protection. The ZnIn2S4 nanosheets are distributed uniformly on the surface of the TiO2 nanowire by a hydrothermal method. The stem-and-leaf-like ZnIn2S4 nanosheet/TiO2 nanowire arrays exhibit excellent photoelectrochemical properties, owing to the energy band structure and large surface area. A maximum photocurrent density of 2 mA cm-2 is achieved for the ZnIn2S4 nanosheet/TiO2 nanowire composite film for a 6 h reaction time under white illumination. Moreover, the potential of the 304 stainless steel coupled with the composite film immediately shifts negatively to -1.17 V (vs. SCE), which is significantly lower than the corrosion potential (-0.201 V vs. SCE). Thus, the composite film offers a superior photocathodic protection for stainless steel against corrosion by a NaCl solution. This study provides a promising approach for the design and synthesis of composite films with enhanced photoelectrochemical performance.

  5. The development of gaseous detectors with solid photocathodes for low temperature applications

    CERN Document Server

    Periale, L.; Iacobaeus, C.; Francke, T.; Lund-Jensen, B.; Pavlopoulos, N.; Picchi, P.; Pietropaolo, F.

    2004-01-01

    There are several applications and fundamental research areas which require the detection of VUV light at cryogenic temperatures. For these applications we have developed and successfully tested special designs of gaseous detectors with solid photocathodes able to operate at low temperatures: sealed gaseous detectors with MgF2 windows and windowless detectors. We have experimentally demonstrated, that both primary and secondary (due to the avalanche multiplication inside liquids) scintillation lights could be recorded by photosensitive gaseous detectors. The results of this work may allow one to significantly improve the operation of some noble liquid gas TPCs.

  6. Lifetime total and beverage specific - alcohol intake and prostate cancer risk: a case-control study

    Directory of Open Access Journals (Sweden)

    Carruba Giuseppe

    2004-12-01

    Full Text Available Abstract Background We investigated lifetime alcohol consumption and prostate cancer risk in a case-control study conducted in Buffalo, NY (1998–2001. Methods The study included 88 men, aged 45 to 85 years with incident, histologically-confirmed prostate cancer and 272 controls. We conducted extensive in-person interviews regarding lifetime alcohol consumption and other epidemiologic data. Results Prostate cancer risk was not associated with lifetime intake of total and beverage specific ethanol. In addition we found no association with number of drinks per day (average drinks per day over the lifetime or drinks per drinking day (average drinks per day on drinking days only over the lifetime. However, we observed an inverse association with the total number of drinking years. Men in the lowest tertile of total drinking years had a two-fold prostate cancer risk than men in the highest tertile (OR 2.16, 95% CI 0.98–4.78, p for trend Conclusion Our results suggest that alcohol intake distribution across lifetime may play a more important role in prostate cancer etiology than total lifetime consumption.

  7. Measurements of Transverse Emittance for RF Photocathode Gun at the PAL

    CERN Document Server

    Park Jang Ho; Park, Sung-Ju; Soo Ko In; Wang, Xijie; Woon Parc, Yong; Xiang, Dao

    2005-01-01

    A BNL GUN-IV type RF photo-cathode gun is under fabrication for use in the FIR (Far Infra-Red) facility being built at the Pohang Accelerator Laboratory (PAL). Performance test of the gun will include the measurement of transverse emittance profile along the longitudinal direction. Successful measurement of the emittance profile will provide powerful tool for the commissioning of the 4GLS (4th generation light source) injectors based on the emittance compensation principle. We are going to achieve this withthe use of pepper-pot based emittance meters that can be moved along the longitudinal direction. In this article, we present design considerations on the emittance meter with the resolution of 1 mm mrad.

  8. Minority Carrier Lifetime and Photoluminescence Studies of Antimony-Based Superlattices

    Science.gov (United States)

    Hoglund, Linda; Soibel, Alexander; Ting, David Z.; Khoshakhlagh, Arezou; Hill, Cory J.; Gunapala, Sarath D.

    2012-01-01

    In this paper, we have used the OMR technique to study the minority carrier lifetimes in three InAs/GaSb-photoluminescence (PL) structures with different number of periods in the absorber: 300, 400 and 600 periods respectively. The feasibility of using a visible 643 nm laser source with short penetration depth for lifetime measurements was studied by comparing the achieved results to measurements performed on the same samples with a 1550 nm IR laser source, which penetrates much deeper into the sample. Despite the differences in excitation wavelengths and penetration depths, the results from both measurements were very similar. This indicates that the diffusion length is long enough to facilitate a homogeneous distribution of excess carriers in the material.

  9. Mining the bulk positron lifetime

    International Nuclear Information System (INIS)

    Aourag, H.; Guittom, A.

    2009-01-01

    We introduce a new approach to investigate the bulk positron lifetimes of new systems based on data-mining techniques. Through data mining of bulk positron lifetimes, we demonstrate the ability to predict the positron lifetimes of new semiconductors on the basis of available semiconductor data already studied. Informatics techniques have been applied to bulk positron lifetimes for different tetrahedrally bounded semiconductors in order to discover computational design rules. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. Spatial decoupling of light absorption and catalytic activity of Ni-Mo-loaded high-aspect-ratio silicon microwire photocathodes

    Science.gov (United States)

    Vijselaar, Wouter; Westerik, Pieter; Veerbeek, Janneke; Tiggelaar, Roald M.; Berenschot, Erwin; Tas, Niels R.; Gardeniers, Han; Huskens, Jurriaan

    2018-03-01

    A solar-driven photoelectrochemical cell provides a promising approach to enable the large-scale conversion and storage of solar energy, but requires the use of Earth-abundant materials. Earth-abundant catalysts for the hydrogen evolution reaction, for example nickel-molybdenum (Ni-Mo), are generally opaque and require high mass loading to obtain high catalytic activity, which in turn leads to parasitic light absorption for the underlying photoabsorber (for example silicon), thus limiting production of hydrogen. Here, we show the fabrication of a highly efficient photocathode by spatially and functionally decoupling light absorption and catalytic activity. Varying the fraction of catalyst coverage over the microwires, and the pitch between the microwires, makes it possible to deconvolute the contributions of catalytic activity and light absorption to the overall device performance. This approach provided a silicon microwire photocathode that exhibited a near-ideal short-circuit photocurrent density of 35.5 mA cm-2, a photovoltage of 495 mV and a fill factor of 62% under AM 1.5G illumination, resulting in an ideal regenerative cell efficiency of 10.8%.

  11. Positron lifetime study of electron-irradiated epoxy resins

    International Nuclear Information System (INIS)

    Suevegh, K.; Vertes, A.; Wojnarovits, L.; Foeldiak, G.; Liszkai, L.; Kajcsos, Zs.

    1990-01-01

    Two bisphenol-A type epoxy resins were irradiated by electron beam and studied afterwards by positron lifetime spectroscopy. An interesting result is that despite of the considerable amount of free-radicals, no inhibition of positronium formation was observed in the two epoxies. Nevertheless, several serious differences were detected between the studied polymers. The results suggest that the radiation-resistant properties of epoxies depend strongly on the amount of the curing agent. (author) 8 refs.; 2 figs

  12. Nuclear lifetimes

    International Nuclear Information System (INIS)

    Caraca, J.M.G.

    1976-01-01

    The importance of the results obtained in experiments of measurement of lifetimes for a detailed knowledge of nuclear structure is referred. Direct methods of measurement of nuclear lifetimes are described, namely, electronic methods, recoil-distance method, doppler shift atenuation method and blocking-method. A brief reference is made to indirect methods for measurement of life-times

  13. Preparation of reflective CsI photocathodes with reproducible high quantum efficiency

    Science.gov (United States)

    Maier-Komor, P.; Bauer, B. B.; Friese, J.; Gernhäuser, R.; Kienle, P.; Körner, H. J.; Montermann, G.; Zeitelhack, K.

    1995-02-01

    CsI as a solid UV-photocathode material has many promising applications in fast gaseous photon detectors. They are proposed in large area Ring Imaging CHerenkov (RICH) devices in forthcoming experiments at various high-energy particle accelerators. A high photon-to-electron conversion efficiency is a basic requirement for the successful operation of these devices. High reproducible quantum efficiencies could be achieved with CsI layers prepared by electron beam evaporation from a water-cooled copper crucible. CsI films were deposited in the thickness range of 30 to 500 μg/cm 2. Absorption coefficients and quantum efficiencies were measured in the wavelength region of 150 nm to 250 nm. The influence of various evaporation parameters on the quantum efficiency were investigated.

  14. Preparation of reflective CsI photocathodes with reproducible high quantum efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Maier-Komor, P. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Bauer, B.B. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Friese, J. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Gernhaeuser, R. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Kienle, P. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Koerner, H.J. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Montermann, G. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Zeitelhack, K. [Technische Univ. Muenchen, Garching (Germany). Physik-Department

    1995-08-01

    CsI as a solid UV-photocathode material has many promising applications in fast gaseous photon detectors. They are proposed in large area Ring Imaging CHerenkov (RICH) devices in forthcoming experiments at various high-energy particle accelerators. A high photon-to-electron conversion efficiency is a basic requirement for the successful operation of these devices. High reproducible quantum efficiencies could be achieved with CsI layers prepared by electron beam evaporation from a water-cooled copper crucible. CsI films were deposited in the thickness range of 30 to 500 {mu}g/cm{sup 2}. Absorption coefficients and quantum efficiencies were measured in the wavelength region of 150 nm to 250 nm. The influence of various evaporation parameters on the quantum efficiency were investigated. (orig.).

  15. Characterization of a pulsed x-ray source for fluorescent lifetime measurements

    International Nuclear Information System (INIS)

    Blankespoor, S.C.; Derenzo, S.E.; Moses, W.W.; Rossington, C.S.; Ito, M.; Oba, K.

    1994-01-01

    To search for new, fast, inorganic scintillators, the authors have developed a bench-top pulsed x-ray source for determining fluorescent lifetimes and wavelengths of compounds in crystal or powdered form. This source uses a light-excited x-ray tube which produces x-rays when light from a laser diode strikes its photocathode. The x-ray tube has a tungsten anode, a beryllium exit window, a 30 kV maximum tube bias, and a 50 μA maximum average cathode current. The laser produces 3 x 10 7 photons at 650 nm per ∼100 ps pulse, with up to 10 7 pulses/sec. The time spread for the laser diode, x-ray tube, and a microchannel plate photomultiplier tube is less than 120 ps fwhm. The mean x-ray energy at tube biases of 20, 25, and 30 kV is 9.4, 10.3, and 11.1 keV, respectively. The authors measured 140, 230, and 330 x-ray photons per laser diode pulse per steradian, at tube biases of 20, 25, and 30 kV, respectively. Background x-rays due to dark current occur at a rate of 1 x 10 6 and 3 x 10 6 photons/sec/steradian at biases of 25 and 30 kV, respectively. Data characterizing the x-ray output with an aluminum filter in the x-ray beam are also presented

  16. Temperature and time dependence of free volume in bisphenol A polycarbonate studied by positron lifetime spectroscopy

    NARCIS (Netherlands)

    Kluin, J.E.; Yu, Z.; Vleeshouwers, S.M.; McGervey, J.D.; Jamieson, A.M.; Simha, R.

    1992-01-01

    New positron lifetime expts. were carried out for Bisphenol-A polycarbonate. The influence of unavoidable pos. charged positron irradn. on the lifetime and intensity of o-positronium (o-Ps) annihilation was studied. Results obtained using a state-of-the-art lifetime spectrometer (count rate 670 cps

  17. Research on DC-RF superconducting photocathode injector for high average power FELs

    International Nuclear Information System (INIS)

    Zhao Kui; Hao Jiankui; Hu Yanle; Zhang Baocheng; Quan Shengwen; Chen Jiaer; Zhuang Jiejia

    2001-01-01

    To obtain high average current electron beams for a high average power Free Electron Laser (FEL), a DC-RF superconducting injector is designed. It consists of a DC extraction gap, a 1+((1)/(2)) superconducting cavity and a coaxial input system. The DC gap, which takes the form of a Pierce configuration, is connected to the 1+((1)/(2)) superconducting cavity. The photocathode is attached to the negative electrode of the DC gap. The anode forms the bottom of the ((1)/(2)) cavity. Simulations are made to model the beam dynamics of the electron beams extracted by the DC gap and accelerated by the superconducting cavity. High quality electron beams with emittance lower than 3 π-mm-mrad can be obtained. The optimization of experiments with the DC gap, as well as the design of experiments with the coaxial coupler have all been completed. An optimized 1+((1)/(2)) superconducting cavity is in the process of being studied and manufactured

  18. Three-dimensional fluorescence lifetime tomography

    International Nuclear Information System (INIS)

    Godavarty, Anuradha; Sevick-Muraca, Eva M.; Eppstein, Margaret J.

    2005-01-01

    Near-infrared fluorescence tomography using molecularly targeted lifetime-sensitive, fluorescent contrast agents have applications for early-stage cancer diagnostics. Yet, although the measurement of fluorescent lifetime imaging microscopy (FLIM) is extensively used in microscopy and spectroscopy applications, demonstration of fluorescence lifetime tomography for medical imaging is limited to two-dimensional studies. Herein, the feasibility of three-dimensional fluorescence-lifetime tomography on clinically relevant phantom volumes is established, using (i) a gain-modulated intensified charge coupled device (CCD) and modulated laser diode imaging system, (ii) two fluorescent contrast agents, e.g., Indocyanine green and 3-3'-Diethylthiatricarbocyanine iodide differing in their fluorescence lifetime by 0.62 ns, and (iii) a two stage approximate extended Kalman filter reconstruction algorithm. Fluorescence measurements of phase and amplitude were acquired on the phantom surface under different target to background fluorescence absorption (70:1, 100:1) and fluorescence lifetime (1:1, 2.1:1) contrasts at target depths of 1.4-2 cm. The Bayesian tomography algorithm was employed to obtain three-dimensional images of lifetime and absorption owing to the fluorophores

  19. Design of a high-brightness, high-duty factor photocathode electron gun

    International Nuclear Information System (INIS)

    Lehrman, I.S.; Birnbaum, I.A.; Fixler, S.Z.; Heuer, R.L.; Siddiqi, S.; Sheedy, E.; Ben-Zvi, I.; Batchelor, K.; Gallardo, J.C.; Kirk, H.G.; Srinivasan-Rao, T.; Warren, G.D.

    1991-09-01

    The proposed UV-FEL user's facility at Brookhaven National Laboratory will require a photocathode gun capable of producing short (< 6 psec) bunches of electrons in high repetition rates (5 kHz), low energy spread (< 1.5.%), a peak current of 300 A (after compression) and a total bunch charge of up to 2 nC. At the highest charge the normalized transverse emittance should be less than 7 π mm-mrad. We are presently designing a gun that is expected to exceed these requirements. This gun will consist of 3 1/2 cells, constructed of GlidCop-15, an aluminum oxide dispersion strengthened copper alloy. The gun will be capable of operating at duty factors in excess of 1%. Extensive beam dynamics studies of the gun were used to determine the effect of varying the length of the first cell, shaping the apertures between cells, and increasing the number of cells. In addition, a detailed thermal and mechanical study of the gun was performed to ensure that the thermal stresses were well within the allowable limits and that copper erosion of the water channels would not occur

  20. Status of SPring-8 Photocathode Rf Gun for Future Light Sources

    CERN Document Server

    Tomizawa, H; Dewa, H; Hanaki, H; Kobayashi, T; Mizuno, A; Suzuki, S; Taniuchi, T; Yanagida, K

    2005-01-01

    We have been studying photocathode single-cell pillbox rf gun for future light sources since 1996. We achieved a rmaximum field gradient of 187 MV/m with chemical-etching processed cavity. We have been developed stable and highly qualified UV-laser source for the rf gun intensively last 3 years. The UV-laser pulse (10 Hz) energy is up to 850 uJ/pulse. The energy stability (rms) of laser has been improved down to 0.2~0.3 % at the fundamental and 0.7~1.3% at the third harmonic generation. This stability is held for two months continuously. In this improvement, we just passively stabilized the system in a humidity-controlled clean room. On the other hand, the ideal spatial and temporal profiles of a shot-by-shot single laser pulse are essential to suppress the emittance growth of the electron beam from the rf gun. We prepared a deformable mirror for spatial shaping, and a spatial light modulator based on fused-silica plates for temporal shaping. With a deformable mirror, we obtained an emittance of1.6

  1. Validity of LIDAS (LIfetime Depression Assessment Self-report): a self-report online assessment of lifetime major depressive disorder.

    Science.gov (United States)

    Bot, M; Middeldorp, C M; de Geus, E J C; Lau, H M; Sinke, M; van Nieuwenhuizen, B; Smit, J H; Boomsma, D I; Penninx, B W J H

    2017-01-01

    There is a paucity of valid, brief instruments for the assessment of lifetime major depressive disorder (MDD) that can be used in, for example, large-scale genomics, imaging or biomarker studies on depression. We developed the LIfetime Depression Assessment Self-report (LIDAS), which assesses lifetime MDD diagnosis according to DSM criteria, and is largely based on the widely used Composite International Diagnostic Interview (CIDI). Here, we tested the feasibility and determined the sensitivity and specificity for measuring lifetime MDD with this new questionnaire, with a regular CIDI as reference. Sensitivity and specificity analyses of the online lifetime MDD questionnaire were performed in adults with (n = 177) and without (n = 87) lifetime MDD according to regular index CIDIs, selected from the Netherlands Study of Depression and Anxiety (NESDA) and Netherlands Twin Register (NTR). Feasibility was tested in an additional non-selective, population-based sample of NTR participants (n = 245). Of the 753 invited persons, 509 (68%) completed the LIDAS, of which 419 (82%) did this online. User-friendliness of the instrument was rated high. Median completion time was 6.2 min. Sensitivity and specificity for lifetime MDD were 85% [95% confidence interval (CI) 80-91%] and 80% (95% CI 72-89%), respectively. This LIDAS instrument gave a lifetime MDD prevalence of 20.8% in the population-based sample. Measuring lifetime MDD with an online instrument was feasible. Sensitivity and specificity were adequate. The instrument gave a prevalence of lifetime MDD in line with reported population prevalences. LIDAS is a promising tool for rapid determination of lifetime MDD status in large samples, such as needed for genomics studies.

  2. Positron annihilation lifetime spectroscopy source correction determination: A simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Kanda, Gurmeet S.; Keeble, David J., E-mail: d.j.keeble@dundee.ac.uk

    2016-02-01

    Positron annihilation lifetime spectroscopy (PALS) can provide sensitive detection and identification of vacancy-related point defects in materials. These measurements are normally performed using a positron source supported, and enclosed by, a thin foil. Annihilation events from this source arrangement must be quantified and are normally subtracted from the spectrum before analysis of the material lifetime components proceeds. Here simulated PALS spectra reproducing source correction evaluation experiments have been systematically fitted and analysed using the packages PALSfit and MELT. Simulations were performed assuming a single lifetime material, and for a material with two lifetime components. Source correction terms representing a directly deposited source and various foil supported sources were added. It is shown that in principle these source terms can be extracted from suitably designed experiments, but that fitting a number of independent, nominally identical, spectra is recommended.

  3. Positron lifetime study of the devitrification process in a cordierite glass

    International Nuclear Information System (INIS)

    Pedrosa, M.A.; Pareja, R.

    1985-01-01

    The devitrification of the 13.3% MgO-32.0% Al 2 O 3 -52.7% SiO 2 -2.0% BaO ceramic-glass via isochronal heating up to a stable crystalline structure has been studied by the positron annihilation technique. The lifetime spectra showed two components. This devitrification results as a two-stage process. The long-lifetime tau 2 , attributed to the pick-off annihilation of ortho-Ps states, decreased on crystallization, but it was insensitive to the hexagonal-orthorhombic transformation of the crystalline cordierite. On the contrary, the effective lifetime of positrons annihilating in states that are not Ps, increased. This increase has been attributed to the Al/Si order process inherent to the hexagonal-orthorhombic transformation. Moreover, the Ps fraction in the crystalline phases was higher than in the glassy phase. However the free volume model might qualitatively explain the relationship observed between I 2 and tau 2 . (author)

  4. Ceramic pot filters lifetime study in coastal Guatemala.

    Science.gov (United States)

    Salvinelli, C; Elmore, A C; García Hernandez, B R; Drake, K D

    2017-02-01

    Ceramic pot filters (CPFs) are an effective means of household water treatment, but the characterization of CPF lifetimes is ongoing. This paper describes a lifetime field study in Guatemala which was made possible by a collaboration between researchers, CPF-using households, and local non-governmental organizations (NGOs). Disinfection data were collected periodically for two years using field coliform enumeration kits as were flow rate data with the assistance of NGO staff. Consumer acceptance was characterized by surveying householders in the four subject villages at the beginning and end of the study. Flow rate data showed that average CPF flow rates decreased below the recommended minimum of 1 L h -1 after 10 months of use; however, the survey results indicated that the consumers were tolerant of the lower flow rates, and it is reasonable to assume that the daily volume of treated water can be readily increased by refilling the CPFs more frequently. Of greater concern was the finding that disinfection efficacy decreased below the recommended bacterial reduction after 14 months of use because it would not be obvious to users that effectiveness had declined. Finally, the follow-up visits by the researchers and the NGO staff appeared to increase consumer acceptance of the CPFs.

  5. A positron annihilation lifetime spectroscopy study of porous silicon using a continuous lifetime fitting algorithm

    International Nuclear Information System (INIS)

    Derlet, P.M.; Choy, T.C.

    1996-01-01

    In the present work we report on a positron annihilation lifetime spectroscopy (PALS) investigation of porous silicon using a continuous lifetime fitting algorithm. Our motivation lies in the underlying disadvantage in discrete lifetime fitting algorithms where the number of components must initially be assumed since in general a realistic spectrum does not uniquely determine this number. This becomes particularly apparent when looking at highly disordered systems where the notion of a discrete spectrum may be invalid and indeed crucial to an understanding of the optical absorption and photo-luminescence properties. Using the PALS data collected from different porous silicon samples in conjunction with other methods of characterisation, we have extended the findings of previous work. In particular we resolve three rather than two ortho-positronium components, suggesting that there may be an additional intermediary scale of porosity in which ortho-positronium annihilates. We also establish the existence of a very weak ortho-positronium component in the pre-anodised wafers at a time scale approximately equal to the longest time ortho-positronium component seen in porous silicon, suggesting that irregularities of a particular magnitude exist before anodisation and that these may, in part, be the catalyst for the initial pore formation process

  6. Lifetime measurements

    International Nuclear Information System (INIS)

    Fossan, D.B.; Warburton, E.K.

    1974-01-01

    Lifetime measurements are discussed, concentrating on the electronic technique, the recoil distance method (RDM), and the Doppler shift attenuation method (DSAM). A brief review of several indirect timing techniques is given, and their specific advantages and applicability are considered. The relationship between lifetimes of nuclear states and the nuclear structure information obtained from them is examined. A short discussion of channeling and microwave methods of lifetime measurement is presented. (23 figures, 171 references) (U.S.)

  7. Quantitative analysis of fluorescence lifetime measurements of the macula using the fluorescence lifetime imaging ophthalmoscope in healthy subjects.

    Science.gov (United States)

    Dysli, Chantal; Quellec, Gwénolé; Abegg, Mathias; Menke, Marcel N; Wolf-Schnurrbusch, Ute; Kowal, Jens; Blatz, Johannes; La Schiazza, Olivier; Leichtle, Alexander B; Wolf, Sebastian; Zinkernagel, Martin S

    2014-04-03

    Fundus autofluorescence (FAF) cannot only be characterized by the intensity or the emission spectrum, but also by its lifetime. As the lifetime of a fluorescent molecule is sensitive to its local microenvironment, this technique may provide more information than fundus autofluorescence imaging. We report here the characteristics and repeatability of FAF lifetime measurements of the human macula using a new fluorescence lifetime imaging ophthalmoscope (FLIO). A total of 31 healthy phakic subjects were included in this study with an age range from 22 to 61 years. For image acquisition, a fluorescence lifetime ophthalmoscope based on a Heidelberg Engineering Spectralis system was used. Fluorescence lifetime maps of the retina were recorded in a short- (498-560 nm) and a long- (560-720 nm) spectral channel. For quantification of fluorescence lifetimes a standard ETDRS grid was used. Mean fluorescence lifetimes were shortest in the fovea, with 208 picoseconds for the short-spectral channel and 239 picoseconds for the long-spectral channel, respectively. Fluorescence lifetimes increased from the central area to the outer ring of the ETDRS grid. The test-retest reliability of FLIO was very high for all ETDRS areas (Spearman's ρ = 0.80 for the short- and 0.97 for the long-spectral channel, P macula in healthy subjects. By using a custom-built software, we were able to quantify fluorescence lifetimes within the ETDRS grid. Establishing a clinically accessible standard against which to measure FAF lifetimes within the retina is a prerequisite for future studies in retinal disease.

  8. A new two-step tuning procedure for a photocathode gun

    International Nuclear Information System (INIS)

    Lal, Shankar; Pant, K.K.; Krishnagopal, S.

    2008-01-01

    An important aspect of the development of multi-cell RF accelerating structures is tuning the resonant frequency f of the operating mode, field balance e b , and waveguide to cavity coupling coefficient β to the desired values. Earlier theoretical analyses have not been able to predict all three parameters simultaneously for a coupled-cavity system. We have developed a generalized circuit analysis to predict f, e b , and β of a coupled structure, based on the RF properties of the individual, uncoupled, cells. This has been used to develop a simplified two-step tuning procedure to tune a BNL/SLAC/UCLA type 1.6 cell S-band photocathode gun by varying RF properties of individual half and full cells, which are easily measurable. This procedure has been validated by tuning two true-to-scale prototypes made of aluminum and ETP copper to the desired values of the RF parameters

  9. Beam dynamics simulations in the photo-cathode RF gun for the CLIC test facility

    International Nuclear Information System (INIS)

    Marchand, P.; Rinolfi, L.

    1992-01-01

    The CERN CLIC Test Facility (CTF) uses an RF gun with a laser driven photo-cathode in order to generate electron pulses of high charge (≥10 nC) and short duration (≤20 ps). The RF gun consists of a 3 GHz 1 + 1/2 cell cavity based on the design originally proposed at BNL which minimizes the non-linearities in the transverse field. The beam dynamics in the cavity is simulated by means of the multiparticle tracking code PARMELA. The results are compared to previous simulations as well as to the first experimental data. (author). 4 refs., 4 tabs., 4 figs

  10. Study, realisation and experimental test of an hyper frequency gun triggered by a subpicosecond laser (CANDELA)

    International Nuclear Information System (INIS)

    Travier, C.

    1995-12-01

    The photo-injector technique is the only one capable of generating very short ( picosecond range) electron pulses. A photocathode illuminated by short pulses of laser radiation (sapphire laser) is placed in a high frequency cavity resonator. The generated electrons can reach relativistic speeds in a few centimeters length, if an accelerating field of several MV / m (here 600 MV / m) is applied to extract them. CANDELA, designed thanks to Parmela code, is the only photo-injector triggered by a sub-picosecond laser. The first experimental results are in agreement with the design and prove that the gun is working properly. A maximum photo-emitted charge of two nano coulombs was obtained from a dispenser photocathode, with a quantum efficiency of one per mil, and a lifetime of a dozen hours. More detailed measurements have to check it works in complete agreement with computerized simulations. (D.L.). 657 refs., 123 figs., 20 tabs

  11. Lifetime risk of developing coronary heart disease in Aboriginal Australians: a cohort study.

    Science.gov (United States)

    Wang, Zhiqiang; Hoy, Wendy E

    2013-01-30

    Lifetime risk of coronary heart disease (CHD) is an important yardstick by which policy makers, clinicians and the general public can assess and promote the awareness and prevention of CHD. The lifetime risk in Aboriginal people is not known. Using a cohort with up to 20 years of follow-up, we estimated the lifetime risk of CHD in Aboriginal people. A cohort study. A remote Aboriginal region. 1115 Aboriginal people from one remote tribal group who were free from CHD at baseline were followed for up to 20 years. During the follow-up period, new CHD incident cases were identified through hospital and death records. We estimated the lifetime risks of CHD with and without adjusting for the presence of competing risk of death from non-CHD causes. Participants were followed up for 17 126 person-years, during which 185 developed CHD and 144 died from non-CHD causes. The average age at which the first CHD event occurred was 48 years for men and 49 years for women. The risk of developing CHD increased with age until 60 years and then decreased with age. Lifetime cumulative risk without adjusting for competing risk was 70.7% for men and 63.8% for women. Adjusting for the presence of competing risk of death from non-CHD causes, the lifetime risk of CHD was 52.6% for men and 49.2% for women. Lifetime risk of CHD is as high as one in two in both Aboriginal men and women. The average age of having first CHD events was under 50 years, much younger than that reported in non-Aboriginal populations. Our data provide useful knowledge for health education, screening and prevention of CHD in Aboriginal people.

  12. Progress on Using NEA Cathodes in an RF Gun

    CERN Document Server

    Fliller, Raymond P; Blüm, Hans; Edwards, Helen; Hüning, Markus; Schultheiss, Tom; Sinclair, Charles K

    2005-01-01

    RF guns have proven useful in multiple accelerator applications, and are an attractive electron source for the ILC. Using a NEA GaAs photocathode in such a gun allows for the production of polarized electron beams. However the lifetime of a NEA cathode in this environment is reduced by ion and electron bombardment and residual gas oxidation. We report progress made with studies to produce a RF gun using a NEA GaAs photocathode to produce polarized electron beams. Attempts to reduce the residual gas pressure in the gun are discussed. Initial measurements of ion flux through the cathode port are compared with simulations of ion bombardment. Future directions are also discussed.

  13. Continuous amorphization of Cu-Zr studied by positron lifetime

    International Nuclear Information System (INIS)

    Wilde, G.; Wuerschum, R.; Rabitsch, H.; Puff, W.

    2006-01-01

    Full text: Solid state amorphization by cold-rolling represents an attractive alternative to commonly used ball-milling. The present work aimed at a free volume study of the process of amorphization. To study the amorphization process binary Cu-Zr alloys were mechanically intermixed by cold rolling. Foils of pure Cu and Zr were stacked to form arrays of composition Cu 60 Zr 40 and folded four times. The folded samples were rolled at a strain rate of approximately 0.1 s -1 to a thickness of about 80 μm and then folded to double the thickness and rolled again to a minimum thickness of 80 μm. This procedure was repeated until the final material was cold-rolled for up to 80 passes. The microstructural changes during cold-rolling were investigated at different stages of the mechanical intermixing process by positron lifetime and 2-dimensional Doppler broadening measurements. The obtained Doppler results are discussed analysing the S-W-plot as well as a two-component fit and the shape of the ratio curves. Finally the results are compared to the lifetime results. (author)

  14. Defect study of Zn-doped p-type gallium antimonide using positron lifetime spectroscopy

    International Nuclear Information System (INIS)

    Ling, C. C.; Fung, S.; Beling, C. D.; Huimin, Weng

    2001-01-01

    Defects in p-type Zn-doped liquid-encapsulated Czochralski--grown GaSb were studied by the positron lifetime technique. The lifetime measurements were performed on the as-grown sample at temperature varying from 15 K to 297 K. A positron trapping center having a characteristic lifetime of 317 ps was identified as the neutral V Ga -related defect. Its concentration in the as-grown sample was found to be in the range of 10 17 --10 18 cm -3 . At an annealing temperature of 300 o C, the V Ga -related defect began annealing out and a new defect capable of trapping positrons was formed. This newly formed defect, having a lifetime value of 379 ps, is attributed to a vacancy--Zn-defect complex. This defect started annealing out at a temperature of 580 o C. A positron shallow trap having binding energy and concentration of 75 meV and 10 18 cm -3 , respectively, was also observed in the as-grown sample. This shallow trap is attributed to positrons forming hydrogenlike Rydberg states with the ionized dopant acceptor Zn

  15. High Performance of Manganese Porphyrin Sensitized p-Type CuFe2O4 Photocathode for Solar Water Splitting to Produce Hydrogen in a Tandem Photoelectrochemical Cell

    Directory of Open Access Journals (Sweden)

    Xia Li

    2018-03-01

    Full Text Available A novel composite composed of (5, 10, 15, 20-tetraphenyl porphinato manganese sensitized p-type CuFe2O4 was developed for constructing the photocathode of a tandem photoelectrochemical (PEC cell. The prepared material was characterized by X-ray diffraction (XRD, transmission electron microscopy (TEM, X-ray photoelectron spectroscopy (XPS and UV-vis diffuse reflectance spectroscopy (DRS. Light-driven water splitting to produce hydrogen can be achieved through the PEC cell, and the results show that H2 and O2 can be collected separately at low applied bias. This work demonstrates that manganese porphyrin sensitized CuFe2O4 is an effective hybrid material for building the photocathode of a PEC cell for solar water splitting to produce H2.

  16. Solution-deposited F:SnO₂/TiO₂ as a base-stable protective layer and antireflective coating for microtextured buried-junction H₂-evolving Si photocathodes.

    Science.gov (United States)

    Kast, Matthew G; Enman, Lisa J; Gurnon, Nicholas J; Nadarajah, Athavan; Boettcher, Shannon W

    2014-12-24

    Protecting Si photocathodes from corrosion is important for developing tandem water-splitting devices operating in basic media. We show that textured commercial Si-pn(+) photovoltaics protected by solution-processed semiconducting/conducting oxides (plausibly suitable for scalable manufacturing) and coupled to thin layers of Ir yield high-performance H2-evolving photocathodes in base. They also serve as excellent test structures to understand corrosion mechanisms and optimize interfacial electrical contacts between various functional layers. Solution-deposited TiO2 protects Si-pn(+) junctions from corrosion for ∼24 h in base, whereas junctions protected by F:SnO2 fail after only 1 h of electrochemical cycling. Interface layers consisting of Ti metal and/or the highly doped F:SnO2 between the Si and TiO2 reduce Si-emitter/oxide/catalyst contact resistance and thus increase fill factor and efficiency. Controlling the oxide thickness led to record photocurrents near 35 mA cm(-2) at 0 V vs RHE and photocathode efficiencies up to 10.9% in the best cells. Degradation, however, was not completely suppressed. We demonstrate that performance degrades by two mechanisms, (1) deposition of impurities onto the thin catalyst layers, even from high-purity base, and (2) catastrophic failure via pinholes in the oxide layers after several days of operation. These results provide insight into the design of hydrogen-evolving photoelectrodes in basic conditions, and highlight challenges.

  17. Flat-beam Rf photocathode sources for linear collider applications

    International Nuclear Information System (INIS)

    Rosenzweig, J.B.

    1991-01-01

    Laser driven rf photocathodes represent a recent advance in high-brightness electron beam sources. The authors investigate here a variation on these devices, that obtained by using a ribbon laser pulse to illuminate the cathode, yielding a flat beam (σ x much-gt σ y ) which has asymmetric emittances at the cathode proportional to the beam size each transverse dimension. The flat-beam geometry mitigates space charge forces which lead to intensity dependent transverse and longitudinal emittance growth, thus limiting the beam brightness. The fundamental limit on achievable emittance and brightness is set by the transverse momentum distribution and peak current density of the photoelectrons (photon energy and cathode material dependent effects) and appears to allow, taking into account space charge and rf effects, normalized emittances ε x -5 m-rad and ε -6 m-rad, with Q = 5 nC and σ z = 1 mm. These source emittances are adequate for superconducting linear collider applications, and could preclude the use of a damping ring for the electrons in these schemes

  18. Study on application of positron lifetime spectroscopy in investigation of radiation influences on nuclear track detector polymer

    International Nuclear Information System (INIS)

    Khuong Thanh Tuan; Tran Dai Nghiep; Nguyen Manh Hung; Nguyen Duc Thanh; Le Anh Tuyen

    2007-01-01

    Study on determination of micro porosity of materials using positron lifetime technique is an advanced and promoted tendency in physics and material science presently. In Vietnam, studies in this field have been carried out by some projects funded by VAEC in recent few years, with their object is determination of porosity of oil-contained rock and polymers. This project is established to study the relationship between characteristic of positron lifetime spectra and micro porosity of polymer material, which a type of nuclear track detector made from, after irradiation. The experimental result shows a linear relation of a particular characteristic of lifetime spectra - intensity of lifetime components above 1 ns - and the density of track in polymer created by irradiation. (author)

  19. Modeling of Diamond Field-Emitter-Arrays for high brightness photocathode applications

    Science.gov (United States)

    Kwan, Thomas; Huang, Chengkun; Piryatinski, Andrei; Lewellen, John; Nichols, Kimberly; Choi, Bo; Pavlenko, Vitaly; Shchegolkov, Dmitry; Nguyen, Dinh; Andrews, Heather; Simakov, Evgenya

    2017-10-01

    We propose to employ Diamond Field-Emitter-Arrays (DFEAs) as high-current-density ultra-low-emittance photocathodes for compact laser-driven dielectric accelerators capable of generating ultra-high brightness electron beams for advanced applications. We develop a semi-classical Monte-Carlo photoemission model for DFEAs that includes carriers' transport to the emitter surface and tunneling through the surface under external fields. The model accounts for the electronic structure size quantization affecting the transport and tunneling process within the sharp diamond tips. We compare this first principle model with other field emission models, such as the Child-Langmuir and Murphy-Good models. By further including effects of carrier photoexcitation, we perform simulations of the DFEAs' photoemission quantum yield and the emitted electron beam. Details of the theoretical model and validation against preliminary experimental data will be presented. Work ssupported by LDRD program at LANL.

  20. Fluorescence lifetime imaging of skin cancer

    Science.gov (United States)

    Patalay, Rakesh; Talbot, Clifford; Munro, Ian; Breunig, Hans Georg; König, Karsten; Alexandrov, Yuri; Warren, Sean; Neil, Mark A. A.; French, Paul M. W.; Chu, Anthony; Stamp, Gordon W.; Dunsby, Chris

    2011-03-01

    Fluorescence intensity imaging and fluorescence lifetime imaging microscopy (FLIM) using two photon microscopy (TPM) have been used to study tissue autofluorescence in ex vivo skin cancer samples. A commercially available system (DermaInspect®) was modified to collect fluorescence intensity and lifetimes in two spectral channels using time correlated single photon counting and depth-resolved steady state measurements of the fluorescence emission spectrum. Uniquely, image segmentation has been used to allow fluorescence lifetimes to be calculated for each cell. An analysis of lifetime values obtained from a range of pigmented and non-pigmented lesions will be presented.

  1. Formation of a p-n heterojunction on GaP photocathodes for H-2 production providing an open-circuit voltage of 710 mV

    DEFF Research Database (Denmark)

    Malizia, Mauro; Seger, Brian; Chorkendorff, Ib

    2014-01-01

    Photocatalytic water splitting for the sustainable production of hydrogen using a two-photon tandem device requires careful optimization of the semiconductors used as photon absorbers. In this work we show how the open-circuit voltage of photocathodes for the hydrogen evolution reaction based on ...

  2. Conceptual design of a bright electron injector based on a laser-driven photocathode rf electron gun

    International Nuclear Information System (INIS)

    Chattopadhyay, S.; Chen, Y.J.; Hopkins, D.; Kim, K.J.; Kung, A.; Miller, R.; Sessler, A.; Young, T.

    1988-09-01

    Conceptual design of a bright electron injector for the 1 GeV high gradient test experiment, envisaged by the LLNL-SLAC-LBL collaboration on the Relativistic Klystron is presented. The design utilizes a high-brightness laser-driven rf photocathode electron gun, similar to the pioneering LANL early studies in concept (different parametrically however), together with achromatic magnetic bunching and transport systems and diagnostics. The design is performed with attention to possible use in an FEL as well. A simple but realistic analytic model including longitudinal and transverse space-charge and rf effects and extensive computer simulation form the basis of the parametric choice for the source. These parameters are used as guides for the design of the picosecond laser system and magnetic bunching section. 4 refs., 5 figs., 2 tabs

  3. Influence of wet chemical cleaning on quantum efficiency of GaN photocathode

    International Nuclear Information System (INIS)

    Wang Xiao-Hui; Gao Pin; Wang Hong-Gang; Li Biao; Chang Ben-Kang

    2013-01-01

    GaN samples 1–3 are cleaned by a 2:2:1 solution of sulfuric acid (98%) to hydrogen peroxide (30%) to de-ionized water; hydrochloric acid (37%); or a 4:1 solution of sulfuric acid (98%) to hydrogen peroxide (30%). The samples are activated by Cs/O after the same annealing process. X-ray photoelectron spectroscopy after the different ways of wet chemical cleaning shows: sample 1 has the largest proportion of Ga, N, and O among the three samples, while its C content is the lowest. After activation the quantum efficiency curves show sample 1 has the best photocathode performance. We think the wet chemical cleaning method is a process which will mainly remove C contamination. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  4. Nuclear lifetime measurement

    International Nuclear Information System (INIS)

    Guillaume, Georges

    Three direct techniques of lifetime measurement are emphasized: electronic methods and two methods based on the Doppler effect (the recoil distance methods or RDM, the Doppler shift attenuation methods or DSAM). Said direct methods are concerned with the direct measurement of the radioactive decay constants of nuclear excited states. They allow lifetimes of nucleus bound states whose deexcitations occur by electromagnetic transitions, to be determined. Other methods for measuring lifetimes are also examined: microwave techniques and those involving the blocking effect in crystals (direct methods) and also various indirect methods of obtaining lifetimes (γ resonance scattering, capture reactions, inelastic electron and nucleus scattering, and Coulomb deexcitation) [fr

  5. FUNDUS AUTOFLUORESCENCE LIFETIMES AND CENTRAL SEROUS CHORIORETINOPATHY.

    Science.gov (United States)

    Dysli, Chantal; Berger, Lieselotte; Wolf, Sebastian; Zinkernagel, Martin S

    2017-11-01

    To quantify retinal fluorescence lifetimes in patients with central serous chorioretinopathy (CSC) and to identify disease specific lifetime characteristics over the course of disease. Forty-seven participants were included in this study. Patients with central serous chorioretinopathy were imaged with fundus photography, fundus autofluorescence, optical coherence tomography, and fluorescence lifetime imaging ophthalmoscopy (FLIO) and compared with age-matched controls. Retinal autofluorescence was excited using a 473-nm blue laser light and emitted fluorescence light was detected in 2 distinct wavelengths channels (498-560 nm and 560-720 nm). Clinical features, mean retinal autofluorescence lifetimes, autofluorescence intensity, and corresponding optical coherence tomography (OCT) images were further analyzed. Thirty-five central serous chorioretinopathy patients with a mean visual acuity of 78 ETDRS letters (range, 50-90; mean Snellen equivalent: 20/32) and 12 age-matched controls were included. In the acute stage of central serous chorioretinopathy, retinal fluorescence lifetimes were shortened by 15% and 17% in the respective wavelength channels. Multiple linear regression analysis showed that fluorescence lifetimes were significantly influenced by the disease duration (P autofluorescence lifetimes, particularly in eyes with retinal pigment epithelial atrophy, were associated with poor visual acuity. This study establishes that autofluorescence lifetime changes occurring in central serous chorioretinopathy exhibit explicit patterns which can be used to estimate perturbations of the outer retinal layers with a high degree of statistical significance.

  6. Product lifetime, energy efficiency and climate change: A case study of air conditioners in Japan.

    Science.gov (United States)

    Nishijima, Daisuke

    2016-10-01

    This study proposed a modelling technique for estimating life-cycle CO2 emissions of durable goods by considering changes in product lifetime and energy efficiency. The stock and flow of durable goods was modelled by Weibull lifetime distributions and the trend in annual energy efficiency (i.e., annual electricity consumption) of an "average" durable good was formulated as a reverse logistic curve including a technologically critical value (i.e., limit energy efficiency) with respect to time. I found that when the average product lifetime is reduced, there is a trade-off between the reduction in emissions during product use (use phase), due to the additional purchases of new, more energy-efficient air conditioners, and the increase in emissions arising from the additional production of new air conditioners stimulated by the reduction of the average product lifetime. A scenario analysis focused on residential air conditioners in Japan during 1972-2013 showed that for a reduction of average lifetime of 1 year, if the air conditioner energy efficiency limit can be improved by 1.4% from the estimated current efficiency level, then CO2 emissions can be reduced by approximately the same amount as for an extension of average product lifetime of 1 year. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Enhanced Photocatalytic Hydrogen Production By Surface Modification of p-Gap Photocathodes

    DEFF Research Database (Denmark)

    Malizia, Mauro; Seger, Brian; Chorkendorff, Ib

    2014-01-01

    of forming a p-n heterojunction on GaP. We deposit different n-type metal oxides (TiO2, Nb2O5, ...) thus forming an heterojunction which significantly enhances charge separation upon light irradiation by forming a built-in potential at the junction interface. This built-in potential effectively drives...... 300 mV compared to the pristine p-GaP semiconductor and marking an unprecedented value of open-circuit voltage for GaP-based photocathodes for hydrogen production. It is found that the high carrier density of the n-type oxides shifts the distribution of the built-in potential almost entirely towards...... the lightly doped p-type substrate and forms an asymmetric charge depletion region at the junction, as depicted in Figure 1. Moreover, TiO2shows excellent stability over long-time operation, unveiling its double role of brilliant material for both heterojunction formation and protection against corrosion...

  8. Multiple Myeloma and lifetime occupation: results from the EPILYMPH study

    Directory of Open Access Journals (Sweden)

    Perrotta Carla

    2012-12-01

    Full Text Available Abstract Background The EPILYMPH study applied a detailed occupational exposure assessment approach to a large multi-centre case–control study conducted in six European countries. This paper analysed multiple myeloma (MM risk associated with level of education, and lifetime occupational history and occupational exposures, based on the EPILYMPH data set. Methods 277 MM cases and four matched controls per each case were included. Controls were randomly selected, matching for age (+/− 5 years, centre and gender. Lifetime occupations and lifetime exposure to specific workplace agents was obtained through a detailed questionnaire. Local industrial hygienists assessed likelihood and intensity for specific exposures. The odds ratio and 95% confidence intervals (OR, 95% CI were calculated for level of education, individual occupations and specific exposures. Unconditional logistic regression models were run for individual occupations and exposures. Results A low level of education was associated with MM OR=1.68 (95% CI 1.02-2.76. An increased risk was observed for general farmers (OR=1.77; 95% CI 1.05-2.99 and cleaning workers (OR=1.69; 95% CI 1.04-2.72 adjusting for level of education. Risk was also elevated, although not significant, for printers (OR=2.06; 95% CI 0.97-4.34. Pesticide exposure over a period of ten years or more increased MM risk (OR=1.62; 95% CI 1.01-2.58. Conclusion These results confirm an association of MM with farm work, and indicate its association with printing and cleaning. While prolonged exposure to pesticides seems to be a risk factor for MM, an excess risk associated with exposure to organic solvents could not be confirmed.

  9. Designing Efficient Solar-Driven Hydrogen Evolution Photocathodes Using Semitransparent MoQxCly(Q = S, Se) Catalysts on Si Micropyramids

    KAUST Repository

    Ding, Qi

    2015-09-21

    © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim. Silicon micropyramids with n+pp+ junctions are demonstrated to be efficient absorbers for integrated solar-driven hydrogen production systems enabling significant improvements in both photocurrent and onset potential. When conformally coated with MoSxCly, a catalyst that has excellent catalytic activity and high optical transparency, the highest photocurrent density for Si-based photocathodes with earth-abundant catalysts is achieved.

  10. Non-conventional photocathodes based on Cu thin films deposited on Y substrate by sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Perrone, A. [Department of Mathematics and Physics “E. De Giorgi”, University of Salento, 73100 Lecce (Italy); National Institute of Nuclear Physics and University of Salento, 73100 Lecce (Italy); D’Elia, M. [Department of Mathematics and Physics “E. De Giorgi”, University of Salento, 73100 Lecce (Italy); Gontad, F., E-mail: francisco.gontad@le.infn.it [Department of Mathematics and Physics “E. De Giorgi”, University of Salento, 73100 Lecce (Italy); National Institute of Nuclear Physics and University of Salento, 73100 Lecce (Italy); Di Giulio, M.; Maruccio, G. [Department of Mathematics and Physics “E. De Giorgi”, University of Salento, 73100 Lecce (Italy); Cola, A. [National Council Research, Institute for Microelectronics and Microsystems, 73100 Lecce (Italy); Stankova, N.E. [Institute of Electronics, Bulgarian Academy of Sciences, 1784 Sofia (Bulgaria); Kovacheva, D.G. [Institute of General and Inorganic Chemistry, Bulgarian Academy of Sciences, 1113 Sofia (Bulgaria); Broitman, E. [Department of Physics, Chemistry and Biology (IFM), Linköping University, SE-581 83 Linköping (Sweden)

    2014-07-01

    Copper (Cu) thin films were deposited on yttrium (Y) substrate by sputtering. During the deposition, a small central area of the Y substrate was shielded to avoid the film deposition and was successively used to study its photoemissive properties. This configuration has two advantages: the cathode presents (i) the quantum efficiency and the work function of Y and (ii) high electrical compatibility when inserted into the conventional radio-frequency gun built with Cu bulk. The photocathode was investigated by scanning electron microscopy to determine surface morphology. X-ray diffraction and atomic force microscopy studies were performed to compare the structure and surface properties of the deposited film. The measured electrical resistivity value of the Cu film was similar to that of high purity Cu bulk. Film to substrate adhesion was also evaluated using the Daimler–Benz Rockwell-C adhesion test method. Finally, the photoelectron performance in terms of quantum efficiency was obtained in a high vacuum photodiode cell before and after laser cleaning procedures. A comparison with the results obtained with a twin sample prepared by pulsed laser deposition is presented and discussed.

  11. Femtosecond precision measurement of laser–rf phase jitter in a photocathode rf gun

    International Nuclear Information System (INIS)

    Shi, Libing; Zhao, Lingrong; Lu, Chao; Jiang, Tao; Liu, Shengguang; Wang, Rui; Zhu, Pengfei; Xiang, Dao

    2017-01-01

    We report on the measurement of the laser–rf phase jitter in a photocathode rf gun with femtosecond precision. In this experiment four laser pulses with equal separation are used to produce electron bunch trains; then the laser–rf phase jitter is obtained by measuring the variations of the electron bunch spacing with an rf deflector. Furthermore, we show that when the gun and the deflector are powered by the same rf source, it is possible to obtain the laser–rf phase jitter in the gun through measurement of the beam–rf phase jitter in the deflector. Based on these measurements, we propose an effective time-stamping method that may be applied in MeV ultrafast electron diffraction facilities to enhance the temporal resolution.

  12. Femtosecond precision measurement of laser–rf phase jitter in a photocathode rf gun

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Libing; Zhao, Lingrong; Lu, Chao; Jiang, Tao; Liu, Shengguang; Wang, Rui; Zhu, Pengfei; Xiang, Dao, E-mail: dxiang@sjtu.edu.cn

    2017-03-21

    We report on the measurement of the laser–rf phase jitter in a photocathode rf gun with femtosecond precision. In this experiment four laser pulses with equal separation are used to produce electron bunch trains; then the laser–rf phase jitter is obtained by measuring the variations of the electron bunch spacing with an rf deflector. Furthermore, we show that when the gun and the deflector are powered by the same rf source, it is possible to obtain the laser–rf phase jitter in the gun through measurement of the beam–rf phase jitter in the deflector. Based on these measurements, we propose an effective time-stamping method that may be applied in MeV ultrafast electron diffraction facilities to enhance the temporal resolution.

  13. Hadronization, spin and lifetimes

    International Nuclear Information System (INIS)

    Grossman, Yuval; Nachshon, Itay

    2008-01-01

    Measurements of lifetimes can be done in two ways. For very short lived particles, the width can be measured. For long lived ones, the lifetime can be directly measured, for example, using a displaced vertex. Practically, the lifetime cannot be extracted for particles with intermediate lifetimes. We show that for such cases information about the lifetime can be extracted for heavy colored particles that can be produced with known polarization. For example, a t-like particle with intermediate lifetime hadronizes into a superposition of the lowest two hadronic states, T* and T (the equivalent of B* and B). Depolarization effects are governed by time scales that are much longer than the hadronization time scale, Λ QCD -1 . After a time of order 1/Δm, with Δm≡m(T*)-m(T), half of the initial polarization is lost. The polarization is totally lost after a time of order 1/Γ γ , with Γ γ = Γ(T* → Tγ). Thus, by comparing the initial and final polarization, we get information on the particle's lifetime.

  14. The Lifetime of a beautiful and charming meson: Bc lifetime measured using the D0 detector

    International Nuclear Information System (INIS)

    Welty-Rieger, Leah Christine

    2008-01-01

    Using approximately 1.3 fb -1 of data collected by the D0 detector between 2002 and 2006, the lifetime of the B c ± meson is studied in the B c ± → J/ψμ ± + X final state. Using an unbinned likelihood simultaneous fit to J/ψ + μ invariant mass and lifetime distributions, a signal of 810 ± 80(stat.) candidates is estimated and a lifetime measurement made of: τ(B c ± ) = 0.448 -0.036 +0.038 (stat) ± 0.032(sys) ps

  15. Thermal stability of grain boundaries in nanocrystalline Zn studied by positron lifetime spectroscopy

    International Nuclear Information System (INIS)

    Zhou Kai; Li Hui; Pang Jinbiao; Wang Zhu

    2012-01-01

    Nanocrystalline Zn prepared by compacting nanoparticles with mean grain size about 55 nm at 15 MPa has been studied by positron lifetime spectroscopy. For the bulk Zn sample, the vacancy defect is annealed out at about 350 °C, but for the nanocrystalline Zn sample, the vacancy cluster in grain boundaries is quite difficult to be annealed out even at very high temperature (410 °C). In the grain boundaries of nanocrystalline Zn, the small free volume defect (not larger than divacancy) is dominant according to the high relative intensity for the short positron lifetime (τ 1 ). The oxide (ZnO) inside the grain boundaries has been found having an effect to hinder the decrease of average positron lifetime (τ av ), which probably indicates that the oxide stabilizes the microstructure of the grain boundaries. This stabilization is very important for the nanocrystalline materials using as radiation resistant materials.

  16. Lifetime Studies of Cs2Te Cathodes at the Phin RF Photoinjector at CERN

    CERN Document Server

    Hessler, C; Divall Csatari, M; Doebert, S; Fedosseev, V

    2012-01-01

    The PHIN photoinjector has been developed to study the feasibility of a photoinjector option for the CLIC (Compact LInear Collider) drive beam as an alternative to the baseline design, using a thermionic gun. The CLIC drive beam requires a high charge of 8.4 nC per bunch in 0.14 ms long trains, with 2 ns bunch spacing and 50 Hz macro pulse repetition rate, which corresponds to a total charge per macro pulse of 0.59 mC. This means unusually high peak and average currents for photoinjectors and is challenging concerning the cathode lifetime. In this paper detailed studies of the lifetime of Cs2Te cathodes, produced by the co-evaporation technique, are presented with respect to bunch charge, train length and vacuum level. Furthermore, the impact of the train length and bunch charge on the vacuum level will be discussed and steps to extend the lifetime will be outlined.

  17. Beyond injection: Trojan horse underdense photocathode plasma wakefield acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Hidding, B.; Rosenzweig, J. B.; Xi, Y.; O' Shea, B.; Andonian, G.; Schiller, D.; Barber, S.; Williams, O.; Pretzler, G.; Koenigstein, T.; Kleeschulte, F.; Hogan, M. J.; Litos, M.; Corde, S.; White, W. W.; Muggli, P.; Bruhwiler, D. L.; Lotov, K. [Institut fuer Laser- und Plasmaphysik, Heinrich-Heine-Universitaet Duesseldorf 40225 Duesseldorf (Germany) and Particle Beam Physics Laboratory, Department for Physics and Astronomy, UCLA (United States); Particle Beam Physics Laboratory, Department for Physics and Astronomy, UCLA (United States); Institut fuer Laser- und Plasmaphysik, Heinrich-Heine-Universitaet Duesseldorf 40225 Duesseldorf (Germany); Stanford Linear Accelerator Center (United States); Max-Planck-Institut fuer Physik, Muenchen (Germany); Tech-X Corporation, Boulder, Colorado (United States) and 1348 Redwood Ave., Boulder, Colorado 80304 (United States); Budker Institute of Nuclear Physics SB RAS, 630090, Novosibirsk (Russian Federation) and Novosibirsk State University, 630090, Novosibirsk (Russian Federation)

    2012-12-21

    An overview on the underlying principles of the hybrid plasma wakefield acceleration scheme dubbed 'Trojan Horse' acceleration is given. The concept is based on laser-controlled release of electrons directly into a particle-beam-driven plasma blowout, paving the way for controlled, shapeable electron bunches with ultralow emittance and ultrahigh brightness. Combining the virtues of a low-ionization-threshold underdense photocathode with the GV/m-scale electric fields of a practically dephasing-free beam-driven plasma blowout, this constitutes a 4th generation electron acceleration scheme. It is applicable as a beam brightness transformer for electron bunches from LWFA and PWFA systems alike. At FACET, the proof-of-concept experiment 'E-210: Trojan Horse Plasma Wakefield Acceleration' has recently been approved and is in preparation. At the same time, various LWFA facilities are currently considered to host experiments aiming at stabilizing and boosting the electron bunch output quality via a trojan horse afterburner stage. Since normalized emittance and brightness can be improved by many orders of magnitude, the scheme is an ideal candidate for light sources such as free-electron-lasers and those based on Thomson scattering and betatron radiation alike.

  18. Lifetime of Bentonites study: hydrothermal stability of saponites; Estudio de longevidad en bentonitas: estabilidad hidrotermal de saponitas

    Energy Technology Data Exchange (ETDEWEB)

    Leguey, S; Cuevas, J; Garralon, A [Universidad Autonoma de Madrid, Facultad de Ciencias, Departamento de Quimica Agricola, Geologia y Geoquimica, Madrid (Spain)

    1996-10-01

    The report studies the lifetime of bentonite and the hydrothermal stability of saponites. The testing comprised determination of physical and chemical properties of clays, the stability of the mineral porosity, lifetime and the wall of clay.

  19. Development of Large Area CsI Photocathodes for the ALICE/HMPID RICH Detector

    CERN Document Server

    Hoedlmoser, H; Schyns, E

    2005-01-01

    The work carried out within the framework of this PhD deals with the measurement of the photoelectric properties of large area thin film Cesium Iodide (CsI) photocathodes (PCs) which are to be used as a photon converter in a proximity focusing RICH detector for High Momentum Particle Identification (HMPID) in the ALICE experiment at the LHC. The objective was to commission a VUV-scanner setup for in-situ measurements of the photoelectric response of the CsI PCs immediately after the thin film coating process and the use of this system to investigate the properties of these photon detectors. Prior to this work and prior to the finalization of the ALICE/HMPID detector design, R&D work investigating the properties of CsI PCs had been performed at CERN and at other laboratories in order to determine possible substrates and optimized thin film coating procedures. These R&D studies were usually carried out with small samples on different substrates and with various procedures with sometimes ambiguous result...

  20. Experimental results from a DC photocathode electron gun for an IR FEL

    International Nuclear Information System (INIS)

    Kehne, D.; Engwall, D.; Legg, R.; Shinn, M.

    1997-01-01

    A 350 keV DC photocathode gun capable of delivering the high-brightness CW electron beam necessary for Jefferson Lab's infrared free-electron laser is described. The gun is to be used with a superconducting radiofrequency linac operating at 1.497 GHz and is mode-locked to the 40th subharmonic of the fundamental using a Nd:YLF drive laser. The gun provides 20--25 ps bunches at up to 135 pC/bunch. Experimental measurements of transverse and longitudinal beam properties are presented. Transverse emittance is measured using a slit-wire scanner emittance meter, and energy spread is measured using the slit and a spectrometer magnet. Longitudinal emittance is measured using a combination of sampling aperture, kicker cavity, slit and spectrometer. Measurements for bunch charges of 135 pC are described and compared with simulations

  1. Synchronizaiton Between Laser and Electron Beam at Photocathode RF Gun

    CERN Document Server

    Sakumi, Akira; Fukasawa, Atsushi; Kumagai, Noritaka; Muroya, Yusa; Tomizawa, Hiromitsu; Ueda, T; Uesaka, Mitsuru; Urakawa, Junji; Yoshii, K

    2005-01-01

    The chemical reactions of hot, room temperature and critical water in a time-range of picosecond and sub-picosecond have been carried out by the 18 MeV S-band linac and a Mg photocathode RF gun with the irradiation of third harmonic Ti: Sapphire laser, at Nuclear Engineering Research Laboratory (NERL), the University of Tokyo. Although this short bunch and 100 fs laser light are enough to perform the experiment of radiation chemistry in the time-range of sub-picosecond, the total time-resolution become worse by the instability of synchronization between laser and radio frequency of linac. We found that the fluctuation of room temperature causes the instability, particularly the cycle of turning on/off of the air-conditioner. It is shown that 0.3 °C (peak-to-peak) fluctuation of the laser-room temperature have approximately corresponded to the instability of 6 ps. We are trying to decrease the fluctuation of the room temperature, together with the local temperature stability of the Ti: Sapphire crysta...

  2. Positron lifetime studies in undoped and Sr doped La2CuO4

    International Nuclear Information System (INIS)

    Sundar, C.S.; Bharathi, A.; Hariharan, Y.; Vasumathi, D.

    1992-01-01

    The results of positron lifetime measurements as a function of temperature, in undoped and Sr doped La 2 CuO 4 are presented. A second component of lifetime with a value of 225 ps is seen to develop after 100degC, whose intensity grows sharply in the range of 100degC to 250degC. The mean lifetime increases from 170 ps to 207 ps as the temperature is increased from room temperature to 300degC. Using the results of the theoretical calculations of positron lifetimes at vacancies in La 2 CuO 4 , it is argued that the increase in lifetime with temperature is due to positron trapping at the thermally generated La vacancies. From a two state trapping model analysis, the formation energy is estimated to be 0.39±0.04 eV

  3. Generation of femtosecond electron single pulse using laser photocathode RF gun

    Energy Technology Data Exchange (ETDEWEB)

    Uesaka, M.; Kinoshita, K.; Watanabe, T. [Nuclear Engineering Research Laboratory, University of Tokyo, Tokai, Ibaraki (JP)] [and others

    1998-11-01

    A new laser photocathode RF electron gun was installed in the second linac of the S-band twin linac system of Nuclear Engineering Research Laboratory(NERL) of University of Tokyo in August in 1997. Since then, the behavior of the new gun has been tested and the characteristic parameters have been evaluated. At the exit of the gun, the energy is 4.7 MeV, the charge per bunch 1 nC, the pulse width is 10 ps(FWHM), respectively, for 6 MW RF power supply from a klystron. The electron bunch is accelerated up to 17 MeV. The horizontal normalized emittance is 1 {pi} mm.mrad. Then, the bunch is compressed to be 440 fs(FWHM) with 0.35 nC by the chicane-type magnetic pulse compressor. The gun is planned to be used for femtosecond X-ray generation via the head-on Thomson scattering and laser wakefield acceleration in 1998. (author)

  4. Studies of unicellular microorganisms Saccharomyces cerevisiae by means of positron annihilation lifetime spectroscopy

    Directory of Open Access Journals (Sweden)

    Kubicz Ewelina

    2015-12-01

    Full Text Available Results of positron annihilation lifetime spectroscopy (PALS and microscopic studies on simple microorganisms, brewing yeasts, are presented. Lifetime of ortho-positronium (o-Ps were found to change from 2.4 to 2.9 ns (longer-lived component for lyophilized and aqueous yeasts, respectively. Also hygroscopicity of yeasts in time was examined, allowing to check how water – the main component of the cell – affects PALS parameters, thus lifetime of o-Ps were found to change from 1.2 to 1.4 ns (shorter-lived component for the dried yeasts. The time sufficient to hydrate the cells was found below 10 hours. In the presence of liquid water, an indication of reorganization of yeast in the molecular scale was observed. Microscopic images of the lyophilized, dried, and wet yeasts with best possible resolution were obtained using inverted microscopy (IM and environmental scanning electron microscopy (ESEM methods. As a result, visible changes to the surface of the cell me mbrane were observed in ESEM images.

  5. Fluorescence lifetime studies of MeV erbium implanted silica glass

    International Nuclear Information System (INIS)

    Lidgard, A.; Polman, A.; Jacobsen, D.C.; Blonder, G.E.; Kistler, R.; Poate, J.M.; Becker, P.C.

    1991-01-01

    MeV erbium ion implantation into various SiO 2 glasses has been studied with the aim of incorporating the rare-earth dopant as an optically active ion in the silica network. The lifetime of the excited state ranges from 1.6 to 12.8 ms, depending on base material and implantation fluence. These results have positive implications for silica-based integrated optical technology. (Author)

  6. Fluorescence lifetime studies of MeV erbium implanted silica glass

    Energy Technology Data Exchange (ETDEWEB)

    Lidgard, A.; Polman, A.; Jacobsen, D.C.; Blonder, G.E.; Kistler, R.; Poate, J.M.; Becker, P.C. (AT and T Bell Labs., Murray Hill, NJ (USA))

    1991-05-23

    MeV erbium ion implantation into various SiO{sub 2} glasses has been studied with the aim of incorporating the rare-earth dopant as an optically active ion in the silica network. The lifetime of the excited state ranges from 1.6 to 12.8 ms, depending on base material and implantation fluence. These results have positive implications for silica-based integrated optical technology. (Author).

  7. Positron lifetime in vacancy clusters. Application to the study of vacancy-impurity interactions

    International Nuclear Information System (INIS)

    Corbel, C.

    1986-02-01

    Positron lifetime measurements are used to study the vacancy recovery (77-650 K) in 20 K electron irradiated dilute gold or iron alloys in stainless steels. Positron lifetimes in clusters of various shapes and structures are calculated to precise the information obtained by measuring the positron lifetime in a vacancy cluster of unknown size and configuration. From the calculations, we have drawn the following conclusions: - the minimal size of an unknown cluster can be deduced from the measurement of the positron lifetime in the cluster; - a decrease of the positron lifetime when the structure of the cluster evolves, means either a decrease of the size of the cluster, or, the appearance of a relaxed configuration. - The positron lifetime is very useful to discriminate between a spatial planar or relaxed configuration and a tri-dimensional one. In AuGe, AuSb, AuTn alloys, vacancy clusters decorated by solute atoms appear at 250 K. Their configurations are different from those in pure Au. Mobile vacancy-solutes complexes are involved in the clustering process in AuGe, AuSb. The clusters are probably decorated by several solute atoms in AuGe and AuSb where the resistivity evidences a clustering of solute atoms. In AuFe, vacancy-single or multi-complexes stable up to 670 K prevent cluster formation. In FeTi, FeSb, FeAu, vacancy migration is hindered by the formation of vacancy-solute complexes up to 315 K (Ti), up to 670 K (Sb), up to 700 K (Au). In FeSi, FeCu, FeAg, tri-dimensional clusters grow less easily than Fe. This is likely due to the formation of several kinds of small decorated clusters with relaxed or planar configurations. They are peculiarly stable, surviving up to 700 K at least. In Si (resp. Ti) doped 59Fe25Ni16Cr, solute atoms retain the vacancies up to 300 K (resp. 320 K) [fr

  8. Lifetime measurements

    International Nuclear Information System (INIS)

    Poletti, A.R.

    1976-01-01

    Recent developments in experimental methods of measuring the lifetimes of excited nuclear states is reviewed in three main areas. (a) Doppler Shift Attenuation Measurements (DSAM) Times: 10 -14 - 10 -11 sec.; (b) Recoil Distance Measurements (RDM) Times: 10 -9 - 10 -12 sec.; (c) Direct Electronic Timing Times: down to 10 -10 sec.; A measurement of an excited state lifetime can answer a large number of different questions. Two examples are discussed: (a) The determination of the lifetime of an isomeric transition in 93 Tc and its use in determining an upper limit for the magnitude of the parity non-conserving matrix element - /Hsub(PN)/17/2 + >. (b) The dependence of the strength of M2 transitions on isospin in nuclei in the 1dsub(3/2) -1fsub(7/2) region. (author)

  9. Dynamic aperture study and lifetime improvement at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Sajaev, V.; Emery, L.

    2006-01-01

    Over the past few years, the optics of the Advanced Photon Source storage ring has been optimized to provide lower natural emittance. Presently, the APS operates at 2.5 nm-rad emittance. The optimization was done at the expense of stronger sextupoles and shorter lifetime. Here we present our work on measurement and understanding of the dynamic aperture of the APS in low-emittance mode. We found good agreement between the dynamic aperture measurements and that of the model derived from the response matrix analysis. Based on the model, we were able to increase the lifetime significantly by optimizing sextupoles, correcting optics, moving a working point, and adjusting rf voltage. The higher lifetime allowed us to decrease operating coupling from 2.5% to 1%.

  10. Use of three-dimensional lognormal dose-response surfaces in lifetime studies of radiation-induced cancer

    International Nuclear Information System (INIS)

    Raabe, O.G.

    1986-01-01

    The three-dimensional lognormal cumulative probability power function was used to provide a unifying dose-response description of the lifetime cancer risk for chronic exposure of experimental animals and people, for risk evaluation, and for scaling between species. Bone tumor fatilities, primarily from alpha irradiation of the skeleton in lifetime studies of beagles injected with 226 Ra, were shown to be well described by this function. This function described cancer risk in lifetime studies as a curved smooth surface depending on radiation exposure rate and elapsed time, such that the principal risk at low dose rates occurred near the end of the normal life span without significant life shortening. Essentially identical functions with the median value of the power function displaced with respect to appropriate RBE values were shown to describe bone-cancer induction primarily from alpha irradiation of the skeleton in lifetime beagle studies with injected 226 Ra, 228 Th, 239 Pu and 241 Am, and with inhaled 238 Pu. Application of this model to human exposures to 226 Ra yielded a response ratio of 3.6; that is, the time required for development of bone cancer in people was 3.6 times longer than for beagles at the same average skeletal dose rate. It was suggested that similar techniques were appropriate to other carcinogens and other critical organs. 20 refs., 8 figs., 3 tabs

  11. Enhanced photocathodic behaviors of Pb(Zr{sub 0.20}Ti{sub 0.80})O{sub 3} films on Si substrates for hydrogen production

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Xiaorong; Dong, Wen; Zheng, Fengang; Fang, Liang; Shen, Mingrong, E-mail: mrshen@suda.edu.cn [College of Physics, Optoelectronics and Energy, Collaborative Innovation Center of Suzhou Nano Science and Technology, Photovoltaic Research Institute of Soochow University & Canadian Solar Inc., and Jiangsu Key Laboratory of Thin Films, Soochow University, 1 Shizi Street, Suzhou 215006 (China)

    2015-06-15

    Wide bandgap ferroelectric Pb(Zr{sub 0.20}Ti{sub 0.80})O{sub 3} films were deposited on indium tin oxide (ITO) coated Si-pn{sup +} substrates with an intention to form efficient Si-pn{sup +}/ITO/Pb(Zr,Ti)O{sub 3} (PZT) photocathode for hydrogen production. Depolarization electric field generated in PZT film due to poling can drive the photogenerated electrons from Si-pn{sup +} junction to PZT film, resulting in enhanced photoelectrochemical activity of the photocathode. Comparing the electrode with as-prepared PZT film, the photocurrent increased from −100 μA cm{sup −2} to −1.2 mA cm{sup −2} at 0 V vs. reversible hydrogen electrode (RHE) and the onset potential from 0.36 V to 0.7 V vs. RHE under 100 mW cm{sup −2} illumination, manifesting the great advantage of depolarization electric field in driving the photogenerated carriers not only in the ferroelectric film but also on the interface of different semiconductors.

  12. Vibrational lifetimes of protein amide modes

    International Nuclear Information System (INIS)

    Peterson, K.A.; Rella, C.A.

    1995-01-01

    Measurement of the lifetimes of vibrational modes in proteins has been achieved with a single frequency infrared pump-probe technique using the Stanford Picosecond Free-electron Laser, These are the first direct measurements of vibrational dynamics in the polyamide structure of proteins. In this study, modes associated with the protein backbone are investigated. Results for the amide I band, which consists mainly of the stretching motion of the carbonyl unit of the amide linkage, show that relaxation from the first vibrational excited level (v=1) to the vibrational ground state (v=0) occurs within 1.5 picoseconds with apparent first order kinetics. Comparison of lifetimes for myoglobin and azurin, which have differing secondary structures, show a small but significant difference. The lifetime for the amide I band of myoglobin is 300 femtoseconds shorter than for azurin. Further measurements are in progress on other backbone vibrational modes and on the temperature dependence of the lifetimes. Comparison of vibrational dynamics for proteins with differing secondary structure and for different vibrational modes within a protein will lead to a greater understanding of energy transfer and dissipation in biological systems. In addition, these results have relevance to tissue ablation studies which have been conducted with pulsed infrared lasers. Vibrational lifetimes are necessary for calculating the rate at which the energy from absorbed infrared photons is converted to equilibrium thermal energy within the irradiated volume. The very fast vibrational lifetimes measured here indicate that mechanisms which involve direct vibrational up-pumping of the amide modes with consecutive laser pulses, leading to bond breakage or weakening, are not valid

  13. Results and Systematic Studies of the UCN Lifetime Experiment at NIST

    Science.gov (United States)

    Huffer, Craig Reeves

    The neutron beta-decay lifetime is important in understanding weak interactions in the framework of the Standard Model, and it is an input to nuclear astrophysics and Big Bang Nucleosynthesis. Current measurements of the neutron beta-decay lifetime disagree, which has motivated additional experiments that are sensitive to different sets of systematic effects. An effort continues at the NIST Center for Neutron Research (NCNR) to improve the statistical and systematic limitations of an experiment to measure the neutron beta-decay lifetime using magnetically trapped UCN. In the experiment, a monoenergetic 0:89 nm cold neutron is incident on a superfluid 4He target within the minimum field region of an Ioffe type magnetic trap. Some of the neutrons are subsequently downscattered by single phonons in the helium to low energies (≈ 200 neV), and those in the appropriate spin state become trapped. The inverse process, upscattering of UCN, is suppressed by the low phonon density in the analysis, data, and systematics will be discussed. After accounting for the systematic effects the measured lifetime disagrees with the current PDG mean neutron beta-decay lifetime by about 9 of our standard deviations, which is a strong indication of unaccounted for systematic effects. Additional 3He contamination will be shown to be the most likely candidate for the additional systematic shift, which motivated the commissioning and initial operation of a heat flush purifier for purifying additional 4He. This work ends with a description of the 4He purifier and its performance.

  14. Real-time monitoring of luminescent lifetime changes of PtOEP oxygen sensing film with LED/photodiode-based time-domain lifetime device.

    Science.gov (United States)

    Ji, Shaomin; Wu, Wanhua; Wu, Yubo; Zhao, Taiyang; Zhou, Fuke; Yang, Yubin; Zhang, Xin; Liang, Xiaofen; Wu, Wenting; Chi, Lina; Wang, Zhonggang; Zhao, Jianzhang

    2009-05-01

    A cost-effective LED/photodiode(PD)-based time-domain luminescent lifetime measuring device with rugged electronics and simplified algorithms was assembled and successfully used to characterize oxygen sensing films, by continuously monitoring phosphorescence lifetime changes of phosphorescent platinum octaethylporphyrin (PtOEP) in cardo poly(aryl ether ketone) polymer (IMPEK-C) vs. variation of the oxygen partial pressure in a gas mixture (O(2)/N(2)). The results determined by both phosphorescence lifetime and intensity monitoring were compared and the lifetime mode gave results which are in good agreement with the intensity mode. The lifetime-based linear Stern-Volmer plot indicates that the PtOEP molecules are nearly homogeneously distributed in the sensing film. The phosphorescent lifetime of the PtOEP film changes from 75 micros in neat N(2) to less than 2 micros in neat O(2). The sensing system (by combination of the PtOEP sensing film with the home-assembled lifetime device) gives a high lifetime-based O(2) sensing resolution, e.g. about 2 micros Torr(-1) for low O(2) concentration (below 3.5% O(2), V/V). This feasible lifetime device configuration is affordable to most sensor laboratories and the device may facilitate the study of O(2) sensing material with the continuous lifetime monitoring method.

  15. Charmed particle lifetimes

    International Nuclear Information System (INIS)

    Rosner, J.L.

    1979-01-01

    Conventional estimates are reviewed for charmed particle lifetimes. Free-quark models give values of (a few) x 10 -13 sec to (a few) x 10 -12 sec. The shorter of these values also follows from an extrapolation based on D → Ke/sup nu/. Possible differences among the lifetimes and production rates of D 0 , D + , F + , C 0 + , the heavy lepton tau, and the fifth quark b are discussed. Extreme values of mixing angles in a six-quark model could extend charmed particle lifetimes by a factor of at most three from the above estimates, while shorter lifetimes than those predicted could occur for some species like D 0 or F + if their nonleptonic decays were enhanced. The predictions are discussed in the light of some current experimental results, and it is estimated that sigma(pp → charm) approx. = 10 μb at 400 GeV/c. 95 references

  16. Influence of bias voltage on the stability of CsI photocathodes exposed to air

    CERN Document Server

    Nitti, M A; Nappi, E; Singh, B K; Valentini, A

    2002-01-01

    We describe a possible correlation between the bias voltage applied to the substrate during the growth of CsI photocathodes and the variation of quantum efficiency (QE) after one day exposure to humid air. It was found that fresh samples are much less sensitive to humid air when a high negative bias voltage was applied during film growth. A model based on surface film interaction with water molecules is presented for the observed effect. X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) measurements have been performed to examine, respectively, the bulk structure and the surface of fresh and exposed CsI samples. Also reported are transmittance measurements for fresh and aged CsI samples in the wavelength range 190-850 nm.

  17. The association of lifetime insight and cognition in psychosis.

    Science.gov (United States)

    Sánchez-Torres, Ana M; Zarzuela, Amalia; Peralta, Victor; Cuesta, Manuel J

    2015-03-01

    Poor insight has been related to poor course in psychosis. However, the role of cognition in insight remains unclear. The aim of this study was to examine the influence of cognition and lifetime psychopathological dimensions on insight in psychosis. We followed up 42 patients with psychotic disorders over 10years. Lifetime psychopathological dimensions and cognitive performance were assessed. Patients were divided into two groups by lifetime patterns of insight and compared with 42 healthy volunteers. Lower IQ and poorer social cognition were associated with higher risks of poorer lifetime insight of feeling ill and global insight respectively. Lifetime negative symptoms were associated with a higher risk of poorer lifetime insight into symptoms. Lifetime lack of insight is independent of cognitive impairment in specific domains, except for social cognition. Higher IQ may contribute to better lifetime awareness of illness, while better ability to manage emotions is involved in lifetime global insight. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. The study of synthetic food dyes by positron annihilation lifetime spectroscopy.

    Science.gov (United States)

    Pivtsaev, A. A.; Razov, V. I.

    2015-06-01

    By method of positron annihilation lifetime spectroscopy (PALS), substances are food dyes were studied: E-102 (Tartrazine), E-124 (Ponso 4R), E 132 (Indigo carmine), E-133 (Brilliant Blue), E-151 (Black Shiny). They are examined for the presence of carcinogenic properties. The difference between dyes having explicit carcinogenic properties and mutagenic properties (non-explicit carcinogens) is established.

  19. Study of positron annihilation lifetime spectroscopy in carbon black-filled HDPE composite

    CERN Document Server

    Zhang Xian Feng; Zhou Xian Yi; Weng Hu Imin; Ye Bang Jiao; Han Rong Dian; Jia Shao Jin; Zhang Zhi Cheng

    2002-01-01

    The variation of the electrical conductivity of high density polyethylene (HDPE) with the carbon black (CB) content was studied using positron annihilation lifetime spectroscopy (PALS) and free-volume model, the crystallinity of HDPE/CB composite and 'percolation' effect were discussed with measurements of conductivity and DSC test

  20. Gut Microbiome Associates With Lifetime Cardiovascular Disease Risk Profile Among Bogalusa Heart Study Participants.

    Science.gov (United States)

    Kelly, Tanika N; Bazzano, Lydia A; Ajami, Nadim J; He, Hua; Zhao, Jinying; Petrosino, Joseph F; Correa, Adolfo; He, Jiang

    2016-09-30

    Few studies have systematically assessed the influence of gut microbiota on cardiovascular disease (CVD) risk. To examine the association between gut microbiota and lifetime CVD risk profile among 55 Bogalusa Heart Study participants with the highest and 57 with the lowest lifetime burdens of CVD risk factors. 16S ribosomal RNA sequencing was conducted on microbial DNA extracted from stool samples of the Bogalusa Heart Study participants. α Diversity, including measures of richness and evenness, and individual genera were tested for associations with lifetime CVD risk profile. Multivariable regression techniques were used to adjust for age, sex, and race (model 1), along with body mass index (model 2) and both body mass index and diet (model 3). In model 1, odds ratios (95% confidence intervals) for each SD increase in richness, measured by the number of observed operational taxonomic units, Chao 1 index, and abundance-based coverage estimator, were 0.62 (0.39-0.99), 0.61 (0.38-0.98), and 0.63 (0.39-0.99), respectively. Associations were consistent in models 2 and 3. Four genera were enriched among those with high versus low CVD risk profile in all models. Model 1 P values were 2.12×10(-3), 7.95×10(-5), 4.39×10(-4), and 1.51×10(-4) for Prevotella 2, Prevotella 7, Tyzzerella, and Tyzzerella 4, respectively. Two genera were depleted among those with high versus low CVD risk profile in all models. Model 1 P values were 2.96×10(-6) and 1.82×10(-4) for Alloprevotella and Catenibacterium, respectively. The current study identified associations of overall microbial richness and 6 microbial genera with lifetime CVD risk. © 2016 American Heart Association, Inc.

  1. Studies of energy levels and lifetimes in neutral and ionized light atoms

    International Nuclear Information System (INIS)

    Huldt, S.

    1980-05-01

    The spectrum of singly ionized Titanium has been analysed by photographic spectral recordings of the light from a hollow- cathod. 1240 classified lines in the region 1200 A - 11000 A and 202 term values are reported. Lifetimes of the 3p 5 5p levels in neutral Argon have been measured by the High-frequency-Deflection technique considering the trapping of radiation from the excited 3p 5 4s level. Energy levels and lifetimes of excited states have been studied with the beam-foil method for selected ions in the atomic number range 7 - 30. Influence of transition probabilities caused by hyper-fine interaction for low members of the Helium iso-electronic sequence i verified. The oscillator strength for the inter-combination transition ls 2 1S 0 -1s3p 3 p 1 is measured in Beryllium-like Nitrogen, Oxygen and Fluorine. Accurate determinations of lifetimes for some of the lowest excited levels in Si I - Si IV and Zn II are reported. A large fraction of circularly polarized light is seen in the 0 VI n=6-7 hydrogenic transition when a 4 MeV beam of oxygen was passed through a tilted carbon foil. (author)

  2. The study of synthetic food dyes by positron annihilation lifetime spectroscopy

    International Nuclear Information System (INIS)

    Pivtsaev, A A; Razov, V I

    2015-01-01

    By method of positron annihilation lifetime spectroscopy (PALS), substances are food dyes were studied: E-102 (Tartrazine), E-124 (Ponso 4R), E 132 (Indigo carmine), E-133 (Brilliant Blue), E-151 (Black Shiny). They are examined for the presence of carcinogenic properties. The difference between dyes having explicit carcinogenic properties and mutagenic properties (non-explicit carcinogens) is established. (paper)

  3. Reliability-based assessment of polyethylene pipe creep lifetime

    International Nuclear Information System (INIS)

    Khelif, Rabia; Chateauneuf, Alaa; Chaoui, Kamel

    2007-01-01

    Lifetime management of underground pipelines is mandatory for safe hydrocarbon transmission and distribution systems. The use of high-density polyethylene tubes subjected to internal pressure, external loading and environmental variations requires a reliability study in order to define the service limits and the optimal operating conditions. In service, the time-dependent phenomena, especially creep, take place during the pipe lifetime, leading to significant strength reduction. In this work, the reliability-based assessment of pipe lifetime models is carried out, in order to propose a probabilistic methodology for lifetime model selection and to determine the pipe safety levels as well as the most important parameters for pipeline reliability. This study is enhanced by parametric analysis on pipe configuration, gas pressure and operating temperature

  4. Reliability-based assessment of polyethylene pipe creep lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Khelif, Rabia [LaMI-UBP and IFMA, Campus de Clermont-Fd, Les Cezeaux, BP 265, 63175 Aubiere Cedex (France); LR3MI, Departement de Genie Mecanique, Universite Badji Mokhtar, BP 12, Annaba 23000 (Algeria)], E-mail: rabia.khelif@ifma.fr; Chateauneuf, Alaa [LGC-University Blaise Pascal, Campus des Cezeaux, BP 206, 63174 Aubiere Cedex (France)], E-mail: alaa.chateauneuf@polytech.univ-bpclermont.fr; Chaoui, Kamel [LR3MI, Departement de Genie Mecanique, Universite Badji Mokhtar, BP 12, Annaba 23000 (Algeria)], E-mail: chaoui@univ-annaba.org

    2007-12-15

    Lifetime management of underground pipelines is mandatory for safe hydrocarbon transmission and distribution systems. The use of high-density polyethylene tubes subjected to internal pressure, external loading and environmental variations requires a reliability study in order to define the service limits and the optimal operating conditions. In service, the time-dependent phenomena, especially creep, take place during the pipe lifetime, leading to significant strength reduction. In this work, the reliability-based assessment of pipe lifetime models is carried out, in order to propose a probabilistic methodology for lifetime model selection and to determine the pipe safety levels as well as the most important parameters for pipeline reliability. This study is enhanced by parametric analysis on pipe configuration, gas pressure and operating temperature.

  5. High-quality electron pulse generation from a laser photocathode RF gun

    International Nuclear Information System (INIS)

    Yang, Jinfeng; Sakai, Fumio; Aoki, Yasushi

    1999-01-01

    A laser photocathode RF gun system was developed for ultra short X-ray pulse generation via the inverse Compton scattering. The gun is a BNL-type S-band RF gun and the performance test of the gun was performed at the Linear Accelerator Facility in the Institute of Scientific and Industries Research, Osaka University. The gun system produced 115 pC electron bunches with the energy of 1.6 MeV under the condition of RF peak power of 1.5 MW and laser pulse energy of 65 μJ. The quantum efficiency and dark current were obtained to be 10 -5 and 0.6 nA at the repetition rate of 10 Hz, respectively. The energy and charge of the electron bunch were measured as a function of laser injection phase. Furthermore, the electron bunches were accelerated up to 117 MeV by three s-band TW linacs and the energy monochromaticity (ΔE/E) of the beam was 1.2%. The transverse emittance was also experimentally investigated at the end of the linacs. (author)

  6. Measurements of heavy quark and lepton lifetimes

    International Nuclear Information System (INIS)

    Jaros, J.A.

    1985-02-01

    The PEP/PETRA energy range has proved to be well-suited for the study of the lifetimes of hadrons containing the b and c quarks and the tau lepton for several reasons. First, these states comprise a large fraction of the total interaction rate in e + e - annihilation and can be cleanly identified. Second, the storage rings have operated at high luminosity and so produced these exotic states copiously. And finally, thanks to the interplay of the Fermi coupling strength, the quark and lepton masses, and the beam energy, the expected decay lengths are in the 1/2 mm range and so are comparatively easy to measure. This pleasant coincidence of cleanly identified and abundant signal with potentially large effects has made possible the first measurements of two fundamental weak couplings, tau → nu/sub tau/W and b → cW. These measurements have provided a sharp test of the standard model and allowed, for the first time, the full determination of the magnitudes of the quark mixing matrix. This paper reviews the lifetime studies made at PEP during the past year. It begins with a brief review of the three detectors, DELCO, MAC and MARK II, which have reported lifetime measurements. Next it discusses two new measurements of the tau lifetime, and briefly reviews a measurement of the D 0 lifetime. Finally, it turns to measurements of the B lifetime, which are discussed in some detail. 18 references, 14 figures, 1 table

  7. Precision lifetime measurements

    International Nuclear Information System (INIS)

    Tanner, C.E.

    1994-01-01

    Precision measurements of atomic lifetimes provide important information necessary for testing atomic theory. The authors employ resonant laser excitation of a fast atomic beam to measure excited state lifetimes by observing the decay-in-flight of the emitted fluorescence. A similar technique was used by Gaupp, et al., who reported measurements with precisions of less than 0.2%. Their program includes lifetime measurements of the low lying p states in alkali and alkali like systems. Motivation for this work comes from a need to test the atomic many-body-perturbation theory (MBPT) that is necessary for interpretation of parity nonconservation experiments in atomic cesium. The authors have measured the cesium 6p 2 P 1/2 and 6p 2 P 3/2 state lifetimes to be 34.934±0.094 ns and 30.499±0.070 ns respectively. With minor changes to the apparatus, they have extended their measurements to include the lithium 2p 2 P 1/2 and 2p 2 P 3/2 states

  8. Improved b lifetime measurement from MAC

    International Nuclear Information System (INIS)

    Ford, W.T.

    1984-03-01

    Two recent publications, from the MAC and Mark II collaborations, have reported the somewhat surprising result that the lifetime of particles made up of b quarks is in the 1 to 2 picosecond range, or somewhat longer than the lifetimes of charm particles. Although the charm decays are favored transitions while those of b particles depend upon off-diagonal elements of the weak flavor mixing matrix, the smallness of the b decay rates in face of the large available phase space indicates that the off-diagonal elements are indeed very small. The possibility for complete determination of the mixing matrix was brought significantly nearer by the availability of the lifetime information; what is needed now is to reduce the uncertainty of the measurements, which was about 33% for both experiments. We describe here an extension of the b lifetime study with the MAC detector, incorporating some new data and improvements in the analysis. 12 references

  9. Low-temperature positron-lifetime studies of proton-irradiated silicon

    DEFF Research Database (Denmark)

    Mäkinen, S.; Rajainmäki, H.; Linderoth, Søren

    1990-01-01

    The positron-lifetime technique has been used to identify defects created in high-purity single-crystal silicon by irradiation with 12-MeV protons at 15 K, and the evolution of the defects has been studied by subsequent annealings between 20 and 650 K. Two clear annealing steps were seen...... in the samples, the first starting at 100 K and the other at 400 K. The first is suggested to be a result of the migration of free, negatively charged monovacancies, and the second is connected to the annealing of some vacancy-impurity complexes, probably negatively charged vacancy-oxygen pairs. The specific...

  10. Electron irradiated liquid encapsulated Czochralski grown undoped gallium antimonide studied by positron lifetime spectroscopy and photoluminescence

    International Nuclear Information System (INIS)

    Ma, S K; Lui, M K; Ling, C C; Fung, S; Beling, C D; Li, K F; Cheah, K W; Gong, M; Hang, H S; Weng, H M

    2004-01-01

    Electron irradiated undoped liquid encapsulated Czochralski (LEC) grown GaSb samples were studied by positron lifetime spectroscopy (PLS) and photoluminescence (PL). In addition to the 315 ps component reported in the previous studies, another defect with a lifetime of 280 ps was also identified in the present electron irradiated samples. The bulk lifetime of the GaSb material was found to be 258 ps. The V Ga,280ps and the V Ga,315ps defects were associated with two independent Ga vacancy related defects having different microstructures. The well known 777 meV PL signal (usually band A) was also observed in the electron irradiated undoped GaSb samples. The band A intensity decreases with increasing electron irradiation dosage and it disappears after the 300 deg. C annealing regardless of the irradiation dosage. The origin of the band A signal is also discussed

  11. Lifetime statistics of quantum chaos studied by a multiscale analysis

    KAUST Repository

    Di Falco, A.

    2012-04-30

    In a series of pump and probe experiments, we study the lifetime statistics of a quantum chaotic resonator when the number of open channels is greater than one. Our design embeds a stadium billiard into a two dimensional photonic crystal realized on a silicon-on-insulator substrate. We calculate resonances through a multiscale procedure that combines energy landscape analysis and wavelet transforms. Experimental data is found to follow the universal predictions arising from random matrix theory with an excellent level of agreement.

  12. A positron lifetime study of properties of light particles in liquids

    International Nuclear Information System (INIS)

    Jacobsen, F.M.

    1981-04-01

    The positron lifetime technique has been used for studying the behaviour of the three light particles: the positron, positronium (Ps) (a bound state of an electron and positron), and excess electron in non-polar liquids. A brief introduction to the subject and a short description of the experimental techniques are given. Further, the principles of the data analyses are discussed in some detail. Positron lifetime measurements have been performed on the liquids: SF 6 , neopentane, hexane, and two viscoelastic organic liquids. The experiments have been performed as function of temperature, e.g., from just above the melting point to above the critical point in the cases of liquid SF 6 and neopentane. In all of the liquids the experimental results show that Ps is formed. The analyses of the lifetime spectra show that the Ps yields as well as the state of Ps in these liquids change with temperature. A detailed discussion of the state of Ps in liquids is given. The present results can be explained fairly well in terms of the Ps bubble model. In liquid SF 6 the experimental results strongly indicate that ortho-Ps can annihilate from two different states. The longest-lived ortho-Ps state seems to be similar to that observed in most liquids while the shortest-lived state seems not to have been observed in any other liquids before. A detailed discussion of the measured Ps yield in liquid neopentane and hexane is given. The Ps yield is interpreted by means of the positron spur model. (author)

  13. Spectroscopy and lifetime of bottom and charm hadrons

    International Nuclear Information System (INIS)

    F. Ukegawa

    2000-01-01

    There are several motivations for studying masses and lifetimes of the hadrons containing a heavy quark, either the bottom or the charm quark. First, the mass and the lifetime are fundamental properties of an elementary particle. Second, the spectroscopy of hadrons gives insights into the QCD potential between quarks. In particular, a symmetry exists for heavy hadrons when the heavy quark mass is taken to be infinite, providing a powerful tool to predict and understand properties of those heavy hadrons. Third, studies of the lifetimes of heavy hadrons probe their decay mechanisms. A measurement of the lifetime, or the total decay width, is necessary when the authors extract magnitudes of elements of the Kobayashi-Maskawa matrix. Again, in the limit of an infinite heavy quark mass things become simple and decay of a heavy hadron should be the decay of the heavy quark Q. This leads to a prediction that all hadrons containing the heavy quark Q should have the same lifetime, that of the quark Q. This is far from reality in the case of charm hadrons, where the D + meson lifetime is about 2.5 times longer than the D 0 meson lifetime. Perhaps the charm quark is not heavy enough. The simple quark decay picture should be a better approximation for the bottom hadrons because of the larger b quark mass. On the experimental side, the measurements and knowledge of the heavy hadrons (in particular bottom hadrons) have significantly improved over the last decade, thanks to high statistics data accumulated by various experiments. The authors shall review recent developments in these studies in the remainder of this manuscript

  14. Image dissector photocathode solar damage test program. [solar radiation shielding using a fast optical lens

    Science.gov (United States)

    Smith, R. A.

    1977-01-01

    Image dissector sensors of the same type which will be used in the NASA shuttle star tracker were used in a series of tests directed towards obtaining solar radiation/time damage criteria. Data were evaluated to determine the predicted level of operability of the star tracker if tube damage became a reality. During the test series a technique for reducing the solar damage effect was conceived and verified. The damage concepts are outlined and the test methods and data obtained which were used for verification of the technique's feasibility are presented. The ability to operate an image dissector sensor with the solar image focussed on the photocathode by a fast optical lens under certain conditions is feasible and the elimination of a mechanical protection device is possible.

  15. Studies on Mathematical Models of Wet Adhesion and Lifetime Prediction of Organic Coating/Steel by Grey System Theory.

    Science.gov (United States)

    Meng, Fandi; Liu, Ying; Liu, Li; Li, Ying; Wang, Fuhui

    2017-06-28

    A rapid degradation of wet adhesion is the key factor controlling coating lifetime, for the organic coatings under marine hydrostatic pressure. The mathematical models of wet adhesion have been studied by Grey System Theory (GST). Grey models (GM) (1, 1) of epoxy varnish (EV) coating/steel and epoxy glass flake (EGF) coating/steel have been established, and a lifetime prediction formula has been proposed on the basis of these models. The precision assessments indicate that the established models are accurate, and the prediction formula is capable of making precise lifetime forecasting of the coatings.

  16. Positron lifetimes in deformed copper

    International Nuclear Information System (INIS)

    Hinode, Kenji; Tanigawa, Shoichiro; Doyama, Masao

    1976-01-01

    Positron lifetime measurements were performed for Cu samples with different densities of lattice defects. The lifetime spectra were successfully resolved into two components with the help of the well established analysis program. Obtained results were quite consistent with those expected from the trapping model. The positron trapping mechanism from free to trapped states and the initial condition of the model were especially checked. Deduced values obtained for tau sub(c) (lifetime of free positrons) and tau sub(t) (lifetime of trapped positrons) were 122+-5 psec and 176+-5 psec, respectively. (auth.)

  17. Accelerated lifetime testing methodology for lifetime estimation of Lithium-ion batteries used in augmented wind power plants

    DEFF Research Database (Denmark)

    Stroe, Daniel Ioan; Swierczynski, Maciej Jozef; Stan, Ana-Irina

    2013-01-01

    The development of lifetime estimation models for Lithium-ion battery cells, which are working under highly variable mission profiles characteristic for wind power plant applications, requires a lot of expenditures and time resources. Therefore, batteries have to be tested under accelerated...... lifetime ageing conditions. This paper presents a three-stage methodology used for accelerated lifetime testing of Lithium-ion batteries. The results obtained at the end of the accelerated ageing process can be used for the parametrization of a performance-degradation lifetime model. In the proposed...... methodology both calendar and cycling lifetime tests are considered since both components are influencing the lifetime of Lithium-ion batteries. The methodology proposes also a lifetime model verification stage, where Lithium-ion battery cells are tested at normal operating conditions using an application...

  18. Heritability of lifetime ecstasy use.

    Science.gov (United States)

    Verweij, Karin J H; Treur, Jorien L; Vreeker, Annabel; Brunt, Tibor M; Willemsen, Gonneke; Boomsma, Dorret I; Vink, Jacqueline M

    2017-09-01

    Ecstasy is a widely used psychoactive drug that users often take because they experience positive effects such as increased euphoria, sociability, elevated mood, and heightened sensations. Ecstasy use is not harmless and several immediate and long term side effects have been identified. Lifetime ecstasy use is likely to be partly influenced by genetic factors, but no twin study has determined the heritability. Here, we apply a classical twin design to a large sample of twins and siblings to estimate the heritability of lifetime ecstasy use. The sample comprised 8500 twins and siblings aged between 18 and 45 years from 5402 families registered at the Netherlands Twin Registry. In 2013-2014 participants filled out a questionnaire including a question whether they had ever used ecstasy. We used the classical twin design to partition the individual differences in liability to ecstasy use into that due to genetic, shared environmental, and residual components. Overall, 10.4% of the sample had used ecstasy during their lifetime, with a somewhat higher prevalence in males than females. Twin modelling indicated that individual differences in liability to lifetime ecstasy use are for 74% due to genetic differences between individuals, whereas shared environmental and residual factors explain a small proportion of its liability (5% and 21%, respectively). Although heritability estimates appeared to be higher for females than males, this difference was not significant. Lifetime ecstasy use is a highly heritable trait, which indicates that some people are genetically more vulnerable to start using ecstasy than others. Copyright © 2017. Published by Elsevier B.V.

  19. RF Design and Operating Performance of the BNL/AES 1.3 GHz Single Cell Superconducting RF Photocathode Electron Gun

    International Nuclear Information System (INIS)

    Cole, Michael; Kneisel, Peter; Ben-Zvi, Ilan; Burrill, Andrew; Hahn, H.; Rao, Triveni; Zhao, Y.

    2005-01-01

    Over the past several years Advanced Energy Systems and BNL have been collaborating on the development and testing of a fully superconducting photocathode electron gun. Over the past year we have begun to realize significant results which have been published elsewhere (1). This paper will review the RF design of the gun under test and present results of its performance under various operating conditions. Results for cavity quality factor will be presented for various operating temperatures and cavity field gradients. We will also discuss future plans for testing using this gun.

  20. Lifetime results from heavy quark systems

    International Nuclear Information System (INIS)

    Papadimitriou, V.

    1997-11-01

    We present the latest measurements of weakly decaying b-hadrons from experiments at e + e - and p anti p colliders. These measurements include the average lifetime of b-hadrons, lifetimes of the B - , B 0 and B 0 s mesons, the average lifetime of b-baryons and lifetimes of the Λ b and Ξ b baryons

  1. Exits in order: How crowding affects particle lifetimes

    Energy Technology Data Exchange (ETDEWEB)

    Penington, Catherine J.; Simpson, Matthew J. [School of Mathematical Sciences, Queensland University of Technology, Brisbane (Australia); Baker, Ruth E. [Mathematical Institute, University of Oxford, Radcliffe Observatory Quarter, Woodstock Road, Oxford (United Kingdom)

    2016-06-28

    Diffusive processes are often represented using stochastic random walk frameworks. The amount of time taken for an individual in a random walk to intersect with an absorbing boundary is a fundamental property that is often referred to as the particle lifetime, or the first passage time. The mean lifetime of particles in a random walk model of diffusion is related to the amount of time required for the diffusive process to reach a steady state. Mathematical analysis describing the mean lifetime of particles in a standard model of diffusion without crowding is well known. However, the lifetime of agents in a random walk with crowding has received much less attention. Since many applications of diffusion in biology and biophysics include crowding effects, here we study a discrete model of diffusion that incorporates crowding. Using simulations, we show that crowding has a dramatic effect on agent lifetimes, and we derive an approximate expression for the mean agent lifetime that includes crowding effects. Our expression matches simulation results very well, and highlights the importance of crowding effects that are sometimes overlooked.

  2. Lifetime Extension Report: Progress on the SAVY-4000 Lifetime Extension Program

    International Nuclear Information System (INIS)

    Welch, Cynthia F.; Smith, Paul Herrick; Weis, Eric M.; Blair, Michael W.; Stone, Timothy Amos; Veirs, Douglas Kirk; Reeves, Kirk Patrick; Karns, Tristan; Oka, Jude M.; Keller, Jennie; Meincke, Linda Jeanne; Torres, Joseph Angelo; Herman, Matthew Joseph; Weaver, Brian Phillip; Adams, Jillian Cathleen; Trautschold, Olivia Carol

    2016-01-01

    The 3-year accelerated aging study of the SAVY-4000 O-ring shows very little evidence of significant degradation to samples subjected to aggressive elevated temperature and radiation conditions. Whole container thermal aging studies followed by helium leakage testing and compression set measurements were used to establish an estimate for a failure criterion for O-ring compression set of ?65 %. The whole container aging studies further show that the air flow and efficiency functions of the filter do not degrade significantly after thermal aging. However, the degradation of the water-resistant function leads to water penetration failure after four months at 210°C, but does not cause failure after 10 months at 120°C (130°C is the maximum operating temperature for the PTFE membrane). The thermal aging data for O-ring compression set do not meet the assumptions of standard time-temperature superposition analysis for accelerated aging studies. Instead, the data suggest that multiple degradation mechanisms are operative, with a reversible mechanism operative at low aging temperatures and an irreversible mechanism dominating at high aging temperatures. To distinguish between these mechanisms, we have measured compression set after allowing the sample to physically relax, thereby minimizing the effect of the reversible mechanism. The resulting data were analyzed using two distinct mathematical methods to obtain a lifetime estimate based on chemical degradation alone. Both methods support a lifetime estimate of greater than 150 years at 80°C. Although the role of the reversible mechanism is not fully understood, it is clear that the contribution to the total compression set is small in comparison to that due to the chemical degradation mechanism. To better understand the chemical degradation mechanism, thermally aged O-ring samples have been characterized by Fourier Transform Infrared (FTIR), Electron Paramagnetic Resonance (EPR), Gel Permeation Chromatography (GPC), and

  3. Lifetime Extension Report: Progress on the SAVY-4000 Lifetime Extension Program

    Energy Technology Data Exchange (ETDEWEB)

    Welch, Cynthia F. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Smith, Paul Herrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Nuclear Process Infrastructure; Weis, Eric M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Blair, Michael W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Stone, Timothy Amos [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Nuclear Process Infrastructure; Veirs, Douglas Kirk [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Manufacturing Engineering and Technology; Reeves, Kirk Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Nuclear Process Infrastructure; Karns, Tristan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Nuclear Process Infrastructure; Oka, Jude M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Nuclear Process Infrastructure; Keller, Jennie [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Meincke, Linda Jeanne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Torres, Joseph Angelo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Herman, Matthew Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Weaver, Brian Phillip [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Computer, Computational, and Statistical Sciences. Statistical Sciences; Adams, Jillian Cathleen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Trautschold, Olivia Carol [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials

    2016-09-20

    The 3-year accelerated aging study of the SAVY-4000 O-ring shows very little evidence of significant degradation to samples subjected to aggressive elevated temperature and radiation conditions. Whole container thermal aging studies followed by helium leakage testing and compression set measurements were used to establish an estimate for a failure criterion for O-ring compression set of ≥65 %. The whole container aging studies further show that the air flow and efficiency functions of the filter do not degrade significantly after thermal aging. However, the degradation of the water-resistant function leads to water penetration failure after four months at 210°C, but does not cause failure after 10 months at 120°C (130°C is the maximum operating temperature for the PTFE membrane). The thermal aging data for O-ring compression set do not meet the assumptions of standard time-temperature superposition analysis for accelerated aging studies. Instead, the data suggest that multiple degradation mechanisms are operative, with a reversible mechanism operative at low aging temperatures and an irreversible mechanism dominating at high aging temperatures. To distinguish between these mechanisms, we have measured compression set after allowing the sample to physically relax, thereby minimizing the effect of the reversible mechanism. The resulting data were analyzed using two distinct mathematical methods to obtain a lifetime estimate based on chemical degradation alone. Both methods support a lifetime estimate of greater than 150 years at 80°C. Although the role of the reversible mechanism is not fully understood, it is clear that the contribution to the total compression set is small in comparison to that due to the chemical degradation mechanism. To better understand the chemical degradation mechanism, thermally aged O-ring samples have been characterized by Fourier Transform Infrared (FTIR), Electron Paramagnetic Resonance (EPR), Gel Permeation Chromatography (GPC

  4. Genotypic-specific variance in Caenorhabditis elegans lifetime fecundity.

    Science.gov (United States)

    Diaz, S Anaid; Viney, Mark

    2014-06-01

    Organisms live in heterogeneous environments, so strategies that maximze fitness in such environments will evolve. Variation in traits is important because it is the raw material on which natural selection acts during evolution. Phenotypic variation is usually thought to be due to genetic variation and/or environmentally induced effects. Therefore, genetically identical individuals in a constant environment should have invariant traits. Clearly, genetically identical individuals do differ phenotypically, usually thought to be due to stochastic processes. It is now becoming clear, especially from studies of unicellular species, that phenotypic variance among genetically identical individuals in a constant environment can be genetically controlled and that therefore, in principle, this can be subject to selection. However, there has been little investigation of these phenomena in multicellular species. Here, we have studied the mean lifetime fecundity (thus a trait likely to be relevant to reproductive success), and variance in lifetime fecundity, in recently-wild isolates of the model nematode Caenorhabditis elegans. We found that these genotypes differed in their variance in lifetime fecundity: some had high variance in fecundity, others very low variance. We find that this variance in lifetime fecundity was negatively related to the mean lifetime fecundity of the lines, and that the variance of the lines was positively correlated between environments. We suggest that the variance in lifetime fecundity may be a bet-hedging strategy used by this species.

  5. Positron Annihilation Lifetime Study of Pure and Doped Polyvinyl Chloride with Al2O3

    International Nuclear Information System (INIS)

    Abdel-Hady, E.E.; Hamdy, F. M. M.; Alaa, H.B.

    2005-01-01

    Positron annihilation lifetime of pure and doped polyvinyl chloride (PVC) with Al 2 O 3 reflect the effect of concentration as well as temperature on free volume. Therefore, variations of the ortho-positronium (o-Ps) lifetime and its intensity have been correlated with changes in the dielectric properties of the pure and doped PVC. The o-Ps lifetime and its intensity show a linear dependence with a discontinuity at 20 % concentration of Al 2 O 3 . The size and the fractional of the o-Ps hole volume were estimated from the positron annihilation parameters. Therefore, the temperature dependence of the electrical conductivity and the positron annihilation parameters on pure and doped PVC with 20 % Al 2 O 3 were studied in the range from 20 to 140 degree C. The shift of the glass transition temperature to lower temperature for the 20 % Al 2 O 3 doped PVC might explain the increase in the electrical conductivity with the concentration of the additive

  6. Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence Ives; Eric Montgomery; Zhigang Pan; Blake Riddick; Donald Feldman; Lou Falce

    2012-09-25

    This program applied reservoir cathode technology to increase the lifetime of cesiated tungsten photocathodes. Cesiated tungsten photocathodes provide a quantum efficiency of approximately 0.08% when cesium is initially applied to the surface. During operation, however, the cesium evaporates from the surface, resulting in a gradual decrease in quantum efficiency. After 4-6 hours of operation, the efficiency drop to below useful levels, requiring recoating on the emission surface. This program developed a cathode geometry where cesium could be continuously diffused to the surface at a rate matching the evaporation rate. This results in constant current emission until the cesium in the reservoir is depleted. Measurements of the evaporation rate indicated that the reservoir should provide cesium for more than 30,000 hours of continuous operation. This is orders of magnitude longer operation then previously available. Experiments also demonstrated that the photocathode could be rejuvenated following contamination from a vacuum leak. Recoating of the emission surface demonstrated that the initial quantum efficiency could be recovered.

  7. Lifetime of organic photovoltaics

    DEFF Research Database (Denmark)

    Corazza, Michael; Krebs, Frederik C; Gevorgyan, Suren A.

    2015-01-01

    tests. Comparison of the indoor and outdoor lifetimes was performed by means of the o-diagram, which constitutes the initial steps towards establishing a method for predicting the lifetime of an organic photovoltaic device under real operational conditions based on a selection of accelerated indoor...

  8. Moisture dependence of positron lifetime in Kevlar-49

    Science.gov (United States)

    Singh, Jag J.; Holt, William H.; Mock, Willis, Jr.

    1984-01-01

    Because of filamentary character of Kevlar-49 aramid fibers, there is some concern about the moisture uptake and its effect on plastic composites reinforced with Kevlar-49 fibers. As part of continuing studies of positron lifetime in polymers, we have measured positron lifetime spectra in Kevlar-49 fibers as a function of their moisture content. The long lifetime component intensities are rather low, being only of the order of 2-3 percent. The measured values of long component lifetimes at various moisture levels in the specimens are as follows: 2072 +/- 173 ps (dry); 2013 +/- 193 ps (20.7 percent saturation); 1665 +/- 85 ps (25.7 percent saturation); 1745 +/- 257 ps (32.1 percent saturation); and 1772 +/- 217 ps (100 percent saturation). It is apparent that the long component lifetime at first decreases and then increases as the specimen moisture content increases. These results have been compared with those inferred from Epon-815 and Epon-815/K-49 composite data.

  9. The Lifetime Prediction of LED Drivers and Lamps

    NARCIS (Netherlands)

    Sun, B.

    2017-01-01

    Light-Emitting Diodes (LEDs) have become a very promising alternative lighting source with the main advantages of a longer lifetime and a higher efficiency than traditional ones. However, the LED lamp’s lifetime is compromised by its driver’s reliability. Although extensive studies have been made on

  10. Accelerated Lifetime Testing Methodology for Lifetime Estimation of Lithium-ion Batteries used in Augmented Wind Power Plants

    DEFF Research Database (Denmark)

    Stroe, Daniel Ioan; Swierczynski, Maciej Jozef; Stan, Ana-Irina

    2014-01-01

    The development of lifetime estimation models for Lithium-ion battery cells, which are working under highly variable mission profiles characteristic for wind power plant applications, requires a lot of expenditures and time resources. Therefore, batteries have to be tested under accelerated...... lifetime ageing conditions. This paper presents a three-stage methodology used for accelerated lifetime testing of Lithium ion batteries. The results obtained at the end of the accelerated ageing process were used for the parametrization of a performance-degradation lifetime model, which is able to predict...... both the capacity fade and the power capability decrease of the selected Lithium-ion battery cells. In the proposed methodology both calendar and cycling lifetime tests were considered since both components are influencing the lifetime of Lithium-ion batteries. Furthermore, the proposed methodology...

  11. The Lifetime of a beautiful and charming meson: Bc lifetime measured using the D0 detector

    Energy Technology Data Exchange (ETDEWEB)

    Welty-Rieger, Leah Christine [Indiana Univ., Bloomington, IN (United States)

    2008-09-01

    Using approximately 1.3 fb-1 of data collected by the D0 detector between 2002 and 2006, the lifetime of the Bc± meson is studied in the Bc± → J/Ψμ± + X final state. Using an unbinned likelihood simultaneous fit to J/Ψ + μ invariant mass and lifetime distributions, a signal of 810 ± 80(stat.) candidates is estimated and a lifetime measurement made of: τ(Bc±) = 0.448-0.036+0.038(stat) ± 0.032(sys) ps.

  12. 1 ms pulse beam generation and acceleration by photo-cathode RF gun

    International Nuclear Information System (INIS)

    Watanabe, Ken; Hayano, Hitoshi; Urakawa, Jyunji

    2012-01-01

    We report successful generation of 1 ms long pulse and multi-bunch electron beam by a normal conducting photo-cathode RF gun at KEK-STF (Superconducting accelerator Test Facility). The 1 ms long Pulse beam generated by the RF gun is delivered to the injection line to examine stable acceleration and precise RF control. The 1 ms pulse beam is also used to demonstrate high brightness X-ray generation by inverse laser Compton scattering which will be also carried out at STF, supported by MEXT Quantum Beam project. The RF gun cavity has been fabricated by DESY-FNAL-KEK collaboration. Performing high power RF process and ethanol rinse to the cavity, a stable operation of the cavity up to 4.0 MW RF input power with ∼1 ms pulse length was achieved by keeping even low dark current. The beam generation test has been started since February 2012, 1 ms pulse was generated in March 2012. We explain about the STF injector and report the basic property of this 1 ms beam generation. (author)

  13. Energy Savings Lifetimes and Persistence

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, Ian M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schiller, Steven R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Billingsley, Megan A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Goldman, Charles A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schwartz, Lisa C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-02-01

    This technical brief explains the concepts of energy savings lifetimes and savings persistence and discusses how program administrators use these factors to calculate savings for efficiency measures, programs and portfolios. Savings lifetime is the length of time that one or more energy efficiency measures or activities save energy, and savings persistence is the change in savings throughout the functional life of a given efficiency measure or activity. Savings lifetimes are essential for assessing the lifecycle benefits and cost effectiveness of efficiency activities and for forecasting loads in resource planning. The brief also provides estimates of savings lifetimes derived from a national collection of costs and savings for electric efficiency programs and portfolios.

  14. Positron Lifetime Study of the Transition from Glassy to Normal Liquid State for Two Phenyl Ethers

    DEFF Research Database (Denmark)

    Pethrick, R. A.; Jacobsen, F. M.; Mogensen, O. E.

    1980-01-01

    Positron lifetime measurements are reported as a function of temperature for bis[m-(m-phenoxyphenoxy)phenyl] ether and m-phenoxyphenyl-m-(m-phenoxyphenoxy)phenyl ether. The decay curves were analysed in terms of three lifetime components; two short lifetimes of typically 200 and 500 ps associated...

  15. SIRTF thermal design modifications to increase lifetime

    Science.gov (United States)

    Petrick, S. W.

    1993-01-01

    An effort was made to increase the predicted lifetime of the SIRTF dewar by lowering the exterior shell temperature, increasing the radiated energy from the vapor cooled shields and reconfiguring the vapor cooled shields. The lifetime increases can be used to increase the scientific return from the mission and as a trade-off against mass and cost. This paper describes the configurations studied, the steady state thermal model used, the analytical methods and the results of the analysis. Much of the heat input to the outside dewar shell is radiative heat transfer from the solar panel. To lower the shell temperature, radiative cooled shields were placed between the solar panel and the dewar shell and between the bus and the dewar shell. Analysis showed that placing a radiator on the outer vapor cooled shield had a significant effect on lifetime. Lengthening the distance between the outer shell and the point where the vapor cooled shields are attached to the support straps also improved lifetime.

  16. Study of lifetimes of low-lying levels in {sup 53}Mn

    Energy Technology Data Exchange (ETDEWEB)

    Singh, K.P.; Oswal, Mumtaz; Behera, B.R.; Kumar, Ashok; Singh, Gulzar [Panjab University, Cyclotron Laboratory, Department of Physics, Centre of Advance Study in Physics, Chandigarh (India)

    2015-05-15

    The properties of low-lying states of {sup 53}Mn were investigated via the {sup 53}Cr(p, n γ){sup 53}Mn reaction using 4.3 MeV proton beam energy. The lifetimes of the levels at 1289.5, 1440.8, 1620.0 and 2273.8 keV excitation energies were measured using the Doppler Shift Attenuation Method (DSAM). The reduced transition probabilities B(M1) and B(E2) were extracted using the measured values of lifetimes for these levels and the mixing ratios from the literature. These values are compared with already known experimental values as well as the shell model calculations using an effective interaction. (orig.)

  17. Design of a high repetition rate S-band photocathode gun

    International Nuclear Information System (INIS)

    Han Janghui; Cox, Matthew; Huang, Houcheng; Pande, Shivaji

    2011-01-01

    Photocathode RF guns have been developed in many laboratories for generating high quality electron beams for free-electron lasers based on linear accelerators. Such guns can generate electron beams with an exceptionally high peak current as well as a small transverse emittance. Their applications have been recently expanded for ultrafast electron diffraction, coherent terahertz radiation, and X-ray or γ-ray radiation by Compton scattering. In this paper, we design an S-band normal-conducting gun with capabilities of high quality beam generation and high repetition rate operation. The RF design and thermal analysis of the gun cavity and coupler are introduced. Optimal position of the gun focusing solenoid for low emittance beam generation is found by performing particle tracking simulations. Then, the gun system is designed to be able to afford the optimal solenoid position. The cooling-water channel surrounding the gun cavity and coupler is designed and analyzed numerically. The pressure in the gun is simulated with a vacuum model containing the detailed inner structure of the gun. An injector for a free-electron laser application is designed by using this gun and the beam dynamics simulation is shown. A cold test with a prototype gun for confirmation of the RF design is reported. - Highlights: → We design an S-band gun for low emittance beam generation and high repetition rate operation. → The RF design and thermal analysis of the gun cavity and coupler are studied. → An FEL injector is designed by using this gun and the beam dynamics simulation is shown. → A cold test with a prototype gun for confirmation of the RF design is reported.

  18. Electrically induced metastability in SI-GaAs studied by positron lifetime spectroscopy

    International Nuclear Information System (INIS)

    Luo, Y.L.; Beling, C.D.; Fung, S.; Ling, C.C.; Lui, M.K.; Mui, W.K.

    2001-01-01

    Recently, a room temperature electrically induced metastability in semi-insulating (SI)-GaAs has been reported in which the normally high resistance state of SI-GaAs converts into a low resistance state when breakdown electric fields are applied to the metal/Si-GaAs/metal system. The low resistance state persists when the electric field is lowered below the breakdown bias and as such may thus be considered as metastable state of the material. To clarify whether the high field breakdown has its origins in some atomic configurational change induced through high energy electron collisions we have employed positron lifetime spectroscopy. Lifetime spectra that have been taken at the same bias in both the high current and low current phases show that the positron lifetime in the metastable state has no change within the experimental error from that of the normal state, thus suggesting that the metastability is most likely of purely electronic origin. (orig.)

  19. The 50 kV inverted source of polarized electrons at ELSA

    International Nuclear Information System (INIS)

    Hillert, Wolfgang; Gowin, Michael; Neff, Berhold

    2001-01-01

    The future medium energy physics program at the electron stretcher accelerator ELSA of Bonn University mainly relies on experiments requiring a beam of polarized electrons and a polarized target. To provide a polarized beam with high polarization and sufficient intensity a pulsed 50 kV inverted gun of polarized electrons has been set into operation. The gun is operated in space charge limitation, producing a peak current of 100 mA in rectangular 1μs long electron pulses. Photocathode lifetime during operation is higher than 3000 hours. Using a Be-InGaAs/Be-AlGaAs superlattice photocathode a polarization of 80% and a corresponding quantum efficiency of 0.4% could be obtained

  20. Review of charm and beauty lifetimes

    International Nuclear Information System (INIS)

    Cheung, Harry W. K.

    1999-01-01

    A review of the latest experimental results on charm and beauty particle lifetimes is presented together with a brief summary of measurement methods used for beauty particle lifetime measurements. There have been significant updates to the D s + /D 0 , B + /B d 0 and Λ b 0 /B d 0 lifetime ratios which have some theoretical implications. However more precise measurements are still needed before one can make conclusive statements about the theory used to calculate the particle lifetimes

  1. The TRIple PLunger for EXotic beams TRIPLEX for excited-state lifetime measurement studies on rare isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Iwasaki, H., E-mail: iwasaki@nscl.msu.edu [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824 (United States); Dewald, A.; Braunroth, T.; Fransen, C. [Institut für Kernphysik der Universität zu Köln, D-50937 Cologne (Germany); Smalley, D. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States); Lemasson, A. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States); GANIL, CEA/DSM-CNRS/IN2P3, Bd Henri Becquerel, BP 55027, F-14076 Caen Cedex 5 (France); Morse, C.; Whitmore, K.; Loelius, C. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824 (United States)

    2016-01-11

    A new device, the TRIple PLunger for EXotic beams (TRIPLEX), has been developed for lifetime measurement studies with rare isotope beams. This plunger device holds up to three metal foils in the beam path and facilitates the recoil distance Doppler-shift technique to measure lifetimes of nuclear excited states in the range of 1 ps to 1 ns. The unique design allows independent movement of the target and the second degrader with respect to a fixed first degrader in between, enabling advanced experimental approaches, such as the differential recoil distance method and the double recoil distance method. The design and control of the device are presented in this paper, together with simulated performances of the new applications. As an example of actual experiments, results from the lifetime measurement of the neutron-rich {sup 17}C isotope performed at the National Superconducting Cyclotron Laboratory are shown.

  2. Temperature dependence study of positronium formation in high density polyethylene by positron annihilation lifetime spectroscopy

    International Nuclear Information System (INIS)

    Nahid, F.; Beling, C.D.; Fung, S.

    2007-01-01

    Positron annihilation lifetime spectroscopy has been used to study the formation of positronium in high density polyethylene as a function of temperature over the range 30 K-350 K. It is observed that the thermal history of the sample, while having no influence on the positronium lifetime, has a strong effect on the formation of positronium. A hysteresis is seen in the positronium formation probability in cooling and heating cycles. This is explained on a two channel formation model, the first channel being through ''blob'' formation and the second through the pick-up of shallow trapped electrons. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  3. Experimental study of the lifetime and phase transition in neutron-rich Zr 98 ,100 ,102

    Science.gov (United States)

    Ansari, S.; Régis, J.-M.; Jolie, J.; Saed-Samii, N.; Warr, N.; Korten, W.; Zielińska, M.; Salsac, M.-D.; Blanc, A.; Jentschel, M.; Köster, U.; Mutti, P.; Soldner, T.; Simpson, G. S.; Drouet, F.; Vancraeyenest, A.; de France, G.; Clément, E.; Stezowski, O.; Ur, C. A.; Urban, W.; Regan, P. H.; Podolyák, Zs.; Larijani, C.; Townsley, C.; Carroll, R.; Wilson, E.; Mach, H.; Fraile, L. M.; Paziy, V.; Olaizola, B.; Vedia, V.; Bruce, A. M.; Roberts, O. J.; Smith, J. F.; Scheck, M.; Kröll, T.; Hartig, A.-L.; Ignatov, A.; Ilieva, S.; Lalkovski, S.; Mǎrginean, N.; Otsuka, T.; Shimizu, N.; Togashi, T.; Tsunoda, Y.

    2017-11-01

    Rapid shape changes are observed for neutron-rich nuclei with A around 100. In particular, a sudden onset of ground-state deformation is observed in the Zr and Sr isotopic chains at N = 60: Low-lying states in N ≤58 nuclei are nearly spherical, while those with N ≥60 have a rotational character. Nuclear lifetimes as short as a few picoseconds can be measured using fast-timing techniques with LaBr3(Ce) scintillators, yielding a key ingredient in the systematic study of the shape evolution in this region. We used neutron-induced fission of 241Pu and 235U to study lifetimes of excited states in fission fragments in the A ˜100 region with the EXILL-FATIMA array located at the PF1B cold neutron beam line at the Institut Laue-Langevin. In particular, we applied the generalized centroid difference method to deduce lifetimes of low-lying states for the nuclei 98Zr (N = 58), 100Zr, and 102Zr (N ≥60 ). The results are discussed in the context of the presumed phase transition in the Zr chain by comparing the experimental transition strengths with the theoretical calculations using the interacting boson model and the Monte Carlo shell model.

  4. Actin cytoskeleton-dependent Rab GTPase-regulated angiotensin type I receptor lysosomal degradation studied by fluorescence lifetime imaging microscopy

    Science.gov (United States)

    Li, Hewang; Yu, Peiying; Sun, Yuansheng; Felder, Robin A.; Periasamy, Ammasi; Jose, Pedro A.

    2010-09-01

    The dynamic regulation of the cellular trafficking of human angiotensin (Ang) type 1 receptor (AT1R) is not well understood. Therefore, we investigated the cellular trafficking of AT1R-enhanced green fluorescent protein (EGFP) (AT1R-EGFP) heterologously expressed in HEK293 cells by determining the change in donor lifetime (AT1R-EGFP) in the presence or absence of acceptor(s) using fluorescence lifetime imaging-fluorescence resonance energy transfer (FRET) microscopy. The average lifetime of AT1R-EGFP in our donor-alone samples was ~2.33 ns. The basal state lifetime was shortened slightly in the presence of Rab5 (2.01+/-0.10 ns) or Rab7 (2.11+/-0.11 ns) labeled with Alexa 555, as the acceptor fluorophore. A 5-min Ang II treatment markedly shortened the lifetime of AT1R-EGFP in the presence of Rab5-Alexa 555 (1.78+/-0.31 ns) but was affected minimally in the presence of Rab7-Alexa 555 (2.09+/-0.37 ns). A 30-min Ang II treatment further decreased the AT1R-EGFP lifetime in the presence of both Rab5- and Rab7-Alexa 555. Latrunculin A but not nocodazole pretreatment blocked the ability of Ang II to shorten the AT1R-EGFP lifetime. The occurrence of FRET between AT1R-EGFP (donor) and LAMP1-Alexa 555 (acceptor) with Ang II stimulation was impaired by photobleaching the acceptor. These studies demonstrate that Ang II-induced AT1R lysosomal degradation through its association with LAMP1 is regulated by Rab5/7 via mechanisms that are dependent on intact actin cytoskeletons.

  5. Time variation of fluorescence lifetime in enhanced cyan fluorescence protein

    International Nuclear Information System (INIS)

    Lee, Soonhyouk; Kim, Soo Yong; Park, Kyoungsook; Jeong, Jinyoung; Chung, Bong Hyun; Kim, Sok Won

    2010-01-01

    The lifetime variations of enhanced cyan fluorescence protein (ECFP) in relatively short integration time bins were studied via time-correlated single photon counting (TCSPC) measurement. We observed that minimum photon counts are necessary for the lifetime estimation to achieve a certain range of variance. The conditions to decrease the variance of lifetime were investigated and the channel width of the measurement of TCSPC data was found to be another important factor for the variance of lifetime. Though the lifetime of ECFP is best fit by a double exponential, a mono exponential fit for the same integration time is more stable. The results may be useful in the analysis of photophysical dynamics for ensemble molecules in short measurement time windows.

  6. Fluorescence Lifetime Imaging in Stargardt Disease: Potential Marker for Disease Progression

    OpenAIRE

    Dysli Chantal; Wolf Sebastian; Hatz Katja; Zinkernagel Martin

    2016-01-01

    PURPOSE The purpose of this study was to describe autofluorescence lifetime characteristics in Stargardt disease (STGD) using fluorescence lifetime imaging ophthalmoscopy (FLIO) and to investigate potential prognostic markers for disease activity and progression. METHODS Fluorescence lifetime data of 16 patients with STGD (mean age, 40 years; range, 22-56 years) and 15 age-matched controls were acquired using a fluorescence lifetime imaging ophthalmoscope based on a Heidelberg Eng...

  7. Insight into carrier lifetime impact on band-modulation devices

    Science.gov (United States)

    Parihar, Mukta Singh; Lee, Kyung Hwa; Park, Hyung Jin; Lacord, Joris; Martinie, Sébastien; Barbé, Jean-Charles; Xu, Yue; El Dirani, Hassan; Taur, Yuan; Cristoloveanu, Sorin; Bawedin, Maryline

    2018-05-01

    A systematic study to model and characterize the band-modulation Z2-FET device is developed bringing light to the relevance of the carrier lifetime influence. This work provides guidelines to optimize the Z2-FETs for sharp switching, ESD protection, and 1T-DRAM applications. Lower carrier lifetime in the Z2-FET helps in attaining the sharp switch. We provide new insights into the correlation between generation/recombination, diffusion, electrostatic barriers and carrier lifetime.

  8. Modulated electron-multiplied fluorescence lifetime imaging microscope: all-solid-state camera for fluorescence lifetime imaging.

    Science.gov (United States)

    Zhao, Qiaole; Schelen, Ben; Schouten, Raymond; van den Oever, Rein; Leenen, René; van Kuijk, Harry; Peters, Inge; Polderdijk, Frank; Bosiers, Jan; Raspe, Marcel; Jalink, Kees; Geert Sander de Jong, Jan; van Geest, Bert; Stoop, Karel; Young, Ian Ted

    2012-12-01

    We have built an all-solid-state camera that is directly modulated at the pixel level for frequency-domain fluorescence lifetime imaging microscopy (FLIM) measurements. This novel camera eliminates the need for an image intensifier through the use of an application-specific charge coupled device design in a frequency-domain FLIM system. The first stage of evaluation for the camera has been carried out. Camera characteristics such as noise distribution, dark current influence, camera gain, sampling density, sensitivity, linearity of photometric response, and optical transfer function have been studied through experiments. We are able to do lifetime measurement using our modulated, electron-multiplied fluorescence lifetime imaging microscope (MEM-FLIM) camera for various objects, e.g., fluorescein solution, fixed green fluorescent protein (GFP) cells, and GFP-actin stained live cells. A detailed comparison of a conventional microchannel plate (MCP)-based FLIM system and the MEM-FLIM system is presented. The MEM-FLIM camera shows higher resolution and a better image quality. The MEM-FLIM camera provides a new opportunity for performing frequency-domain FLIM.

  9. Lifetime measurement in neutron-rich A ∝ 100 nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Ansari, Saba; Jolie, Jan; Regis, Jean-Marc; Saed-Samii, Nima; Warr, Nigel [Institute for Nuclear Physics, University of Cologne, Cologne (Germany); Collaboration: EXILL-FATIMA-Collaboration

    2016-07-01

    Rapid shape changes are observed in the region of neutron rich nuclei with a mass around A=100. Precise lifetime measurements are a key ingredient in the systematic study of the evolution of nuclear deformation and the degree of collectivity in this region. Nuclear lifetimes of excited states can be obtained using the fast-timing technique with LaBr{sub 3}(Ce)-scintillators. We used neutron induced fission of {sup 241}Pu in order to study lifetimes of excited states of fission fragments in the A∝100 region. The EXILL-FATIMA array located at the PF1B cold neutron beam line at the Institut Laue-Langevin comprises of 8 BGO-shielded EXOGAM clover detectors and 16 very fast LaBr{sub 3}(Ce)-scintillator detectors, which were installed around the fission target. We have studied the lifetimes of low lying states for the nuclei {sup 98}Zr, {sup 100}Zr and {sup 102}Zr by applying the generalized centroid difference method. In this contribution we report on the used fast-timing setup and present preliminary results for the studied isotopes.

  10. Lifetimes of some b-flavored hadrons

    International Nuclear Information System (INIS)

    Stone, S.

    2014-06-01

    Recent measurements of lifetimes of some b-flavored hadrons are presented and interpreted in the context of theoretical models, especially the Heavy Quark Expansion. Decay widths and decay width differences in the B s 0 - B-bar s 0 system are discussed from the studies of decays into the final states J/ψK + K - , J/ψπ + π - , D s + D s - , K + K - and D s ± π ± . Lifetime measurements of the baryons Λ b 0 , Ξ b - , Ξ b 0 , and Ω b - are also shown. (author)

  11. Positron lifetime in vanadium oxide bronzes

    International Nuclear Information System (INIS)

    Dryzek, J.; Dryzek, E.

    2003-01-01

    The positron lifetime (PL) and Doppler broadening (DB) of annihilation line measurements have been performed in vanadium oxide bronzes M x V 2 O 5 . The dependence of these annihilation characteristics on the kind and concentration of the metal M donor has been observed. In the PL spectrum only one lifetime component has been detected in all studied bronzes. The results indicate the positron localization in the structural tunnels present in the crystalline lattice of the vanadium oxide bronzes. (copyright 2003 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  12. Accelerated lifetime test of vibration isolator made of Metal Rubber material

    Science.gov (United States)

    Ao, Hongrui; Ma, Yong; Wang, Xianbiao; Chen, Jianye; Jiang, Hongyuan

    2017-01-01

    The Metal Rubber material (MR) is a kind of material with nonlinear damping characteristics for its application in the field of aerospace, petrochemical industry and so on. The study on the lifetime of MR material is impendent to its application in engineering. Based on the dynamic characteristic of MR, the accelerated lifetime experiments of vibration isolators made of MR working under random vibration load were conducted. The effects of structural parameters of MR components on the lifetime of isolators were studied and modelled with the fitting curves of degradation data. The lifetime prediction methods were proposed based on the models.

  13. The Susquehanna plant lifetime excellence program

    International Nuclear Information System (INIS)

    McNamara, R.W.

    1988-01-01

    This paper discusses how the Susquehanna plant lifetime excellence program (SPLEX) blends many of the objectives of a new managing for excellence program with plant life extension objectives to achieve excellence in the lifetime operation and availability of the two-unit Susquehanna steam electric station. Investments in lifetime excellence improvements will provide near-term, as well as plant life extension, benefits. A high-quality lifetime experience record, together with extensive, periodic technical assessments and cost-benefit analyses, will provide conclusive justification for future extensions of the unit operating licenses

  14. Measurement of Charm Meson Lifetimes

    International Nuclear Information System (INIS)

    Bonvicini, G.; Cinabro, D.; Greene, R.; Perera, L.P.; Zhou, G.J.; Chan, S.; Eigen, G.; Lipeles, E.; Schmidtler, M.; Shapiro, A.; Sun, W.M.; Urheim, J.; Weinstein, A.J.; Wuerthwein, F.; Jaffe, D.E.; Masek, G.; Paar, H.P.; Potter, E.M.; Prell, S.; Sharma, V.; Asner, D.M.; Eppich, A.; Gronberg, J.; Hill, T.S.; Korte, C.M.; Lange, D.J.; Morrison, R.J.; Nelson, H.N.; Nelson, T.K.; Roberts, D.; Tajima, H.; Behrens, B.H.; Ford, W.T.; Gritsan, A.; Krieg, H.; Roy, J.; Smith, J.G.; Alexander, J.P.; Baker, R.; Bebek, C.; Berger, B.E.; Berkelman, K.; Boisvert, V.; Cassel, D.G.; Crowcroft, D.S.; Dickson, M.; Dombrowski, S. von; Drell, P.S.; Dumas, D.J.; Ecklund, K.M.; Ehrlich, R.; Foland, A.D.; Gaidarev, P.; Gibbons, L.; Gittelman, B.; Gray, S.W.; Hartill, D.L.; Heltsley, B.K.; Henderson, S.; Hopman, P.I.; Katayama, N.; Kreinick, D.L.; Lee, T.; Liu, Y.; Meyer, T.O.; Mistry, N.B.; Ng, C.R.; Nordberg, E.; Ogg, M.; Patterson, J.R.; Peterson, D.; Riley, D.; Soffer, A.; Thayer, J.G.; Thies, P.G.; Valant-Spaight, B.; Warburton, A.; Ward, C.; Athanas, M.; Avery, P.; Jones, C.D.; Lohner, M.; Prescott, C.; Rubiera, A.I.; Yelton, J.; Zheng, J.; Brandenburg, G.; Briere, R.A.; Ershov, A.; Gao, Y.S.; Kim, D.Y.; Wilson, R.; Browder, T.E.; Li, Y.; Rodriguez, J.L.; Yamamoto, H.; Bergfeld, T.; Eisenstein, B.I.; Ernst, J.; Gladding, G.E.; Gollin, G.D

    1999-01-01

    We report measurements of the D 0 , D + , and D + s meson lifetimes using 3.7 fb -1 of e + e - annihilation data collected near the Υ(4S) resonance with the CLEO detector. The measured lifetimes of the D 0 , D + , and D + s mesons are 408.5±4.1 +3.5 -3.4 fs , 1033.6±22.1 +9.9 -12.7 fs , and 486.3±15.0 +4.9 -5.1 fs . The precision of these lifetimes are comparable to those of the best previous measurements, and the systematic errors are very different. In a single experiment we find that the ratio of the D + s and D 0 lifetimes is 1.19±0.04 . copyright 1999 The American Physical Society

  15. Predicting sample lifetimes in creep fracture of heterogeneous materials

    Science.gov (United States)

    Koivisto, Juha; Ovaska, Markus; Miksic, Amandine; Laurson, Lasse; Alava, Mikko J.

    2016-08-01

    Materials flow—under creep or constant loads—and, finally, fail. The prediction of sample lifetimes is an important and highly challenging problem because of the inherently heterogeneous nature of most materials that results in large sample-to-sample lifetime fluctuations, even under the same conditions. We study creep deformation of paper sheets as one heterogeneous material and thus show how to predict lifetimes of individual samples by exploiting the "universal" features in the sample-inherent creep curves, particularly the passage to an accelerating creep rate. Using simulations of a viscoelastic fiber bundle model, we illustrate how deformation localization controls the shape of the creep curve and thus the degree of lifetime predictability.

  16. CO2 absorption of perovskites as seen by positron lifetime spectroscopy

    International Nuclear Information System (INIS)

    Suevegh, K.; Nomura, K.; Juhasz, G.; Homonnay, Z.; Vertes, A.

    2000-01-01

    The CO 2 absorption of several ABO 3 type perovskites was studied by positron lifetime spectroscopy. The longer positron lifetime was associated with positrons trapped by A site vacancies. The evaluated positron lifetime data indicated the relative stability of the crystal structure of Sr(Co 0.5 Fe 0.5 )O 3-δ against Ca doping at low Ca concentrations. Oxygen desorption and CO 2 absorption/desorption could also be followed by positron lifetime spectroscopy. It was shown that the concentration of oxygen vacancies has a large effect on positron lifetime data through the electron density of A site vacancies.

  17. Angular distributions as lifetime probes

    Energy Technology Data Exchange (ETDEWEB)

    Dror, Jeff Asaf; Grossman, Yuval [Department of Physics, LEPP, Cornell University,Ithaca, NY 14853 (United States)

    2014-06-27

    If new TeV scale particles are discovered, it will be important to determine their width. There is, however, a problematic region, where the width is too small to be determined directly, and too large to generate a secondary vertex. For a collection of colored, spin polarized particles, hadronization depolarizes the particles prior to their decay. The amount of depolarization can be used to probe the lifetime in the problematic region. In this paper we apply this method to a realistic scenario of a top-like particle that can be produced at the LHC. We study how depolarization affects the angular distributions of the decay products and derive an equation for the distributions that is sensitive to the lifetime.

  18. Autofluorescence Lifetimes in Geographic Atrophy in Patients With Age-Related Macular Degeneration.

    Science.gov (United States)

    Dysli, Chantal; Wolf, Sebastian; Zinkernagel, Martin S

    2016-05-01

    To investigate fluorescence lifetime characteristics in patients with geographic atrophy (GA) in eyes with age-related macular degeneration and to correlate the measurements with clinical data and optical coherence tomography (OCT) findings. Patients with GA were imaged with a fluorescence lifetime imaging ophthalmoscope. Retinal autofluorescence lifetimes were measured in a short and a long spectral channel (498-560 nm and 560-720 nm). Mean retinal fluorescence lifetimes were analyzed within GA and the surrounding retina, and data were correlated with best corrected visual acuity and OCT measurements. Fluorescence lifetime maps of 41 eyes of 41 patients (80 ± 7 years) with GA were analyzed. Mean lifetimes within areas of atrophy were prolonged by 624 ± 276 ps (+152%) in the short spectral channel and 418 ± 186 ps (+83%) in the long spectral channel compared to the surrounding tissue. Autofluorescence lifetime abnormalities in GA occurred with particular patterns, similar to those seen in fundus autofluorescence intensity images. Within the fovea short mean autofluorescence lifetimes were observed, presumably representing macular pigment. Short lifetimes were preserved even in the absence of foveal sparing but were decreased in patients with advanced retinal atrophy in OCT. Short lifetimes in the fovea correlated with better best corrected visual acuity in both spectral channels. This study established that autofluorescence lifetime changes in GA present with explicit patterns. We hypothesize that the short lifetimes seen within the atrophy may be used to estimate damage induced by atrophy and to monitor disease progression in the context of natural history or interventional therapeutic studies.

  19. Singlet Exciton Lifetimes in Conjugated Polymer Films for Organic Solar Cells

    KAUST Repository

    Dimitrov, Stoichko

    2016-01-13

    The lifetime of singlet excitons in conjugated polymer films is a key factor taken into account during organic solar cell device optimization. It determines the singlet exciton diffusion lengths in polymer films and has a direct impact on the photocurrent generation by organic solar cell devices. However, very little is known about the material properties controlling the lifetimes of singlet excitons, with most of our knowledge originating from studies of small organic molecules. Herein, we provide a brief summary of the nature of the excited states in conjugated polymer films and then present an analysis of the singlet exciton lifetimes of 16 semiconducting polymers. The exciton lifetimes of seven of the studied polymers were measured using ultrafast transient absorption spectroscopy and compared to the lifetimes of seven of the most common photoactive polymers found in the literature. A plot of the logarithm of the rate of exciton decay vs. the polymer optical bandgap reveals a medium correlation between lifetime and bandgap, thus suggesting that the Energy Gap Law may be valid for these systems. This therefore suggests that small bandgap polymers can suffer from short exciton lifetimes, which may limit their performance in organic solar cell devices. In addition, the impact of film crystallinity on the exciton lifetime was assessed for a small bandgap diketopyrrolopyrrole co-polymer. It is observed that the increase of polymer film crystallinity leads to reduction in exciton lifetime and optical bandgap again in agreement with the Energy Gap Law.

  20. The role of technology, product lifetime, and energy efficiency in climate mitigation: A case study of air conditioners in Japan

    International Nuclear Information System (INIS)

    Nishijima, Daisuke

    2017-01-01

    This study analyzed the impact on the life-cycle CO_2 emissions derived from a specific durable good (i.e., household air conditioners in this study) of industrial technology changes, product lifetime changes, and energy efficiency improvements. I proposed a comprehensive structural decomposition analysis including two factors of average lifetime and energy efficiency trend of household air conditioners and applied the decomposition method to the Japanese environmental input-output tables of 1990, 1995, 2000, and 2005. The empirical results show that “Household air-conditioner sector” itself contributed to reducing life-cycle CO_2 emissions derived from household air conditioners, while other sectors such as “On-site power generation sector” and “Retail trade sector” contributed to increasing life-cycle CO_2 emissions derived from household air conditioners. I also conducted combined scenario analysis about reduction potential of product lifetime and energy efficiency of air conditioners and the results showed the reduction rate of energy efficiency necessary for maintain CO_2 emissions in 2005 at 1990 level on each average lifetime scenario. (e.g. if average lifetime of air conditioners is shortened by 1 year, energy efficiency of air conditioners have to be further improved by 20.6% from current level. - Highlights: • This study provides a decomposition framework for air conditioner’s CO_2 emissions. • Technology, product lifetime and energy efficiency are considered in the framework. • “Household air conditioner” sector contributed to reducing CO_2 emissions largely. • “On-site power generation” indirectly contributed to increasing CO_2 emissions. • I showed the improvement rates of energy efficiency to achieve a reduction target.

  1. Lifetime physical activity and female stress urinary incontinence.

    Science.gov (United States)

    Nygaard, Ingrid E; Shaw, Janet M; Bardsley, Tyler; Egger, Marlene J

    2015-07-01

    We sought to estimate whether moderate/severe stress urinary incontinence (SUI) in middle-aged women is associated with overall lifetime physical activity (including leisure, household, outdoor, and occupational), as well as lifetime leisure (recreational), lifetime strenuous, and strenuous activity during the teen years. Recruitment for this case-control study was conducted in primary-care-level family medicine and gynecology clinics. A total of 1538 enrolled women ages 39-65 years underwent a Pelvic Organ Prolapse Quantification examination to assess vaginal support. Based on Incontinence Severity Index scores, cases had moderate/severe and controls had no/mild SUI. We excluded 349 with vaginal descent at/below the hymen (pelvic organ prolapse), 194 who did not return questionnaires, and 110 with insufficient activity data for analysis. In all, 213 cases were frequency matched 1:1 by age group to controls. Physical activity was measured using the Lifetime Physical Activity Questionnaire, in which women recall activity from menarche to present. We created separate multivariable logistic regression models for activity measures. SUI odds increased slightly with overall lifetime activity (odds ratio [OR], 1.20 per 70 additional metabolic equivalent of task-h/wk; 95% confidence interval [CI], 1.02-1.41), and were not associated with lifetime strenuous activity (OR, 1.11; 95% CI, 0.99-1.25). In quintile analysis of lifetime leisure activity, which demonstrated a nonlinear pattern, all quintiles incurred about half the odds of SUI compared to reference (second quintile; P = .009). Greater strenuous activity in teen years modestly increased SUI odds (OR, 1.37 per 7 additional h/wk; 95% CI, 1.09-1.71); OR, 1.75; 95% CI, 1.15-2.66 in sensitivity analysis adjusting for measurement error. The predicted probability of SUI rose linearly in women exceeding 7.5 hours of strenuous activity/wk during teen years. Teen strenuous activity had a similar effect on SUI odds when

  2. CVD grown 2D MoS{sub 2} layers: A photoluminescence and fluorescence lifetime imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Oezden, Ayberk; Madenoglu, Buesra [Department of Materials Science and Engineering, Faculty of Engineering, Anadolu University, Eskisehir (Turkey); Sar, Hueseyin; Ay, Feridun; Perkgoez, Nihan Kosku [Department of Electrical and Electronics Engineering, Faculty of Engineering, Anadolu University, Eskisehir (Turkey); Yeltik, Aydan [Department of Physics, UNAM Institute of Materials Science and Nanotechnology, Bilkent University, Ankara (Turkey); Sevik, Cem [Department of Mechanical Engineering, Faculty of Engineering, Anadolu University, Eskisehir (Turkey)

    2016-11-15

    In this letter, we report on the fluorescence lifetime imaging and accompanying photoluminescence properties of a chemical vapour deposition (CVD) grown atomically thin material, MoS{sub 2}. μ-Raman, μ-photoluminescence (PL) and fluorescence lifetime imaging microscopy (FLIM) are utilized to probe the fluorescence lifetime and photoluminescence properties of individual flakes of MoS{sub 2} films. Usage of these three techniques allows identification of the grown layers, grain boundaries, structural defects and their relative effects on the PL and fluorescence lifetime spectra. Our investigation on individual monolayer flakes reveals a clear increase of the fluorescence lifetime from 0.3 ns to 0.45 ns at the edges with respect to interior region. On the other hand, investigation of the film layer reveals quenching of PL intensity and lifetime at the grain boundaries. These results could be important for applications where the activity of edges is important such as in photocatalytic water splitting. Finally, it has been demonstrated that PL mapping and FLIM are viable techniques for the investigation of the grain-boundaries. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. Lifetime and past-year prevalence of children's exposure to violence in 9 Balkan countries: the BECAN study.

    Science.gov (United States)

    Nikolaidis, George; Petroulaki, Kiki; Zarokosta, Foteini; Tsirigoti, Antonia; Hazizaj, Altin; Cenko, Enila; Brkic-Smigoc, Jelena; Vajzovic, Emir; Stancheva, Vaska; Chincheva, Stefka; Ajdukovic, Marina; Rajter, Miro; Raleva, Marija; Trpcevska, Liljana; Roth, Maria; Antal, Imola; Ispanovic, Veronika; Hanak, Natasha; Olmezoglu-Sofuoglu, Zeynep; Umit-Bal, Ismail; Bianchi, Donata; Meinck, Franziska; Browne, Kevin

    2018-01-01

    Children's exposure to violence is a major public health issue. The Balkan epidemiological study on Child Abuse and Neglect project aimed to collect internationally comparable data on violence exposures in childhood. A three stage stratified random sample of 42,194 school-attending children (response rate: 66.7%) in three grades (aged 11, 13 and 16 years) was drawn from schools in Albania, Bosnia and Herzegovina, Bulgaria, Croatia, Former Yugoslavian Republic of Macedonia (FYROM), Greece, Romania, Serbia and Turkey. Children completed the ICAST-C questionnaire, which measures children's exposure to violence by any perpetrator. Exposure rates for psychological violence were between 64.6% (FYROM) and 83.2% (Greece) for lifetime and 59.62% (Serbia) and 70.0% (Greece) for past-year prevalence. Physical violence exposure varied between 50.6% (FYROM) and 76.3% (Greece) for lifetime and 42.5% (FYROM) and 51.0% (Bosnia) for past-year prevalence. Sexual violence figures were highest for lifetime prevalence in Bosnia (18.6%) and lowest in FYROM (7.6%). Lifetime contact sexual violence was highest in Bosnia (9.8%) and lowest in Romania (3.6%). Past-year sexual violence and contact sexual violence prevalence was lowest in Romania (5.0 and 2.1%) and highest in Bosnia (13.6 and 7.7% respectively). Self-reported neglect was highest for both past-year and lifetime prevalence in Bosnia (48.0 and 20.3%) and lowest in Romania (22.6 and 16.7%). Experiences of positive parental practices were reported by most participating children in all countries. Where significant differences in violence exposure by sex were observed, males reported higher exposure to past-year and lifetime sexual violence and females higher exposure to neglect. Children in Balkan countries experience a high burden of violence victimization and national-level programming and child protection policy making is urgently needed to address this.

  4. Femtosecond timing-jitter between photo-cathode laser and ultra-short electron bunches by means of hybrid compression

    CERN Document Server

    Pompili, Riccardo; Bellaveglia, M; Biagioni, A; Castorina, G; Chiadroni, E; Cianchi, A; Croia, M; Di Giovenale, D; Ferrario, M; Filippi, F; Gallo, A; Gatti, G; Giorgianni, F; Giribono, A; Li, W; Lupi, S; Mostacci, A; Petrarca, M; Piersanti, L; Di Pirro, G; Romeo, S; Scifo, J; Shpakov, V; Vaccarezza, C; Villa, F

    2017-01-01

    The generation of ultra-short electron bunches with ultra-low timing-jitter relative to the photo-cathode (PC) laser has been experimentally proved for the first time at the SPARC_LAB test-facility (INFN-LNF, Frascati) exploiting a two-stage hybrid compression scheme. The first stage employs RF-based compression (velocity-bunching), which shortens the bunch and imprints an energy chirp on it. The second stage is performed in a non-isochronous dogleg line, where the compression is completed resulting in a final bunch duration below 90 fs (rms). At the same time, the beam arrival timing-jitter with respect to the PC laser has been measured to be lower than 20 fs (rms). The reported results have been validated with numerical simulations.

  5. Femtosecond timing-jitter between photo-cathode laser and ultra-short electron bunches by means of hybrid compression

    International Nuclear Information System (INIS)

    Pompili, R; Anania, M P; Bellaveglia, M; Biagioni, A; Castorina, G; Chiadroni, E; Croia, M; Giovenale, D Di; Ferrario, M; Gallo, A; Gatti, G; Cianchi, A; Filippi, F; Giorgianni, F; Giribono, A; Lupi, S; Mostacci, A; Petrarca, M; Piersanti, L; Li, W

    2016-01-01

    The generation of ultra-short electron bunches with ultra-low timing-jitter relative to the photo-cathode (PC) laser has been experimentally proved for the first time at the SPARC-LAB test-facility (INFN-LNF, Frascati) exploiting a two-stage hybrid compression scheme. The first stage employs RF-based compression (velocity-bunching), which shortens the bunch and imprints an energy chirp on it. The second stage is performed in a non-isochronous dogleg line, where the compression is completed resulting in a final bunch duration below 90 fs (rms). At the same time, the beam arrival timing-jitter with respect to the PC laser has been measured to be lower than 20 fs (rms). The reported results have been validated with numerical simulations. (paper)

  6. Lifetime-Aware Cloud Data Centers: Models and Performance Evaluation

    Directory of Open Access Journals (Sweden)

    Luca Chiaraviglio

    2016-06-01

    Full Text Available We present a model to evaluate the server lifetime in cloud data centers (DCs. In particular, when the server power level is decreased, the failure rate tends to be reduced as a consequence of the limited number of components powered on. However, the variation between the different power states triggers a failure rate increase. We therefore consider these two effects in a server lifetime model, subject to an energy-aware management policy. We then evaluate our model in a realistic case study. Our results show that the impact on the server lifetime is far from negligible. As a consequence, we argue that a lifetime-aware approach should be pursued to decide how and when to apply a power state change to a server.

  7. Development of a pico-second life-time spectrometer for positron annihilation studies

    International Nuclear Information System (INIS)

    Pujari, P.K.; Datta, T.; Tomar, B.S.; Das, S.K.

    1992-01-01

    Positron annihilation technique is a sensitive probe to investigate various physico-chemical phenomena due to the ability to provide information about the electron momentum and density in any medium. While measurements on the Doppler broadening and angular correlation of annihilation photons provide information about the electron momentum, the electron density at the annihilation site is obtained, by the positron life-time measurement. This report describes the development, optimization and calibration of a high resolution life-time spectrometer (FWHM=230 ps), based on fast-fast coincidence technique, a relatively new concept in nuclear timing spectroscopy. (author). 4 refs., 9 figs., 1 tab

  8. Lifetime of piezoceramic multilayer actuators : interplay of material properties and actuator design

    NARCIS (Netherlands)

    Ende, D.A. van den; Bos, B.; Groen, W.A.; Dortmans, L.M.J.G.

    2009-01-01

    We report an investigation into factors limiting the functional lifetime of multilayer piezoceramic actuators. The study consists of a combination of lifetime experiments by means of an accelerated lifetime test, inspection of the actuator microstructure at different stages of the accelerated

  9. Emittance measurement and optimization for the photocathode RF gun with laser profile shaping

    International Nuclear Information System (INIS)

    Liu Shengguang; Masafumi Fukuda; Sakae Araki; Nobuhiro Terunuma; Junji Urakawa

    2010-01-01

    The Laser Undulator Compact X-ray source (LUCX) is a test bench for a compact high brightness X-ray generator, based on inverse Compton Scattering at KEK, which requires high intensity multi-bunch trains with low transverse emittance. A photocathode RF gun with emittance compensation solenoid is used as an electron source. Much endeavor has been made to increase the beam intensity in the multi-bunch trains. The cavity of the RF gun is tuned into an unbalanced field in order to reduce space charge effects, so that the field gradient on the cathode surface is relatively higher when the forward RF power into gun cavity is not high enough. A laser profile shaper is employed to convert the driving laser profile from Gaussian into uniform. In this research we seek to find the optimized operational conditions for the decrease of the transverse emittance. With the uniform driving laser and the unbalanced RF gun, the RMS transverse emittance of a 1 nC bunch has been improved effectively from 5.46 πmm.mrad to 3.66 πmm·mrad. (authors)

  10. Study on the effect of deposition rate and concentration of Eu on the fluorescent lifetime of CsI: Tl thin film

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Yijun; Guo, Lina [University of Electronic Science and Technology of China, State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, Chengdu 610054 (China); Liu, Shuang, E-mail: shuangliu@uestc.edu.cn [University of Electronic Science and Technology of China, State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, Chengdu 610054 (China); Wang, Qianfeng; Zhang, Shangjian; Liu, Yong [University of Electronic Science and Technology of China, State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, Chengdu 610054 (China); Zhong, Zhiyong [University of Electronic Science and Technology of China, State Key Laboratory of Electronic Thin Films and Integrated Devices, Chengdu 610054 (China)

    2017-06-21

    Although there are many new scintillators being developed recently, CsI: Tl is still very efficient among them. The fluorescent lifetime is a very important parameter of CsI: Tl thin film and two series of experiments have been conducted to learn about it. Our experiments, however, have demonstrated that the deposition rate and the codoping of Eu{sup 2+} will significantly influence its fluorescent lifetime. In order to increase the efficiency of the imaging system, we intend to obtain a higher fluorescent lifetime for CsI: Tl thin film by controlling these two conditions. - Highlights: • We used vacuum vapor deposition method to grow the high-quality thin films. • The relationship between the deposition rate and the fluorescent lifetime of CsI: Tl thin film was tested. • Concentration of Eu on fluorescent lifetime of the CsI: Tl thin film was studied.

  11. Lifetimes of charm and beauty hadrons

    International Nuclear Information System (INIS)

    Bellini, G.; Dornan, P.J.

    1997-01-01

    Major breakthroughs have been achieved in the determination of the lifetimes of charm and beauty hadrons. Much larger data samples than previously have become available and new experimental devices and techniques have been developed and employed. The lifetimes of all weakly decaying singly charmed hadrons have been measured, some with an accuracy of a few percent. The difference in the shortest lifetime - τ(Ω c ) - and the longest one - τ(D + ) - is given by a factor of close to ten. The experimental status of beauty lifetimes, while less complete, has still reached a new level of quality and is now better than 5% for the commoner states. New theoretical tools, based mainly on heavy quark expansions, have been developed; they incorporate as well as transcend earlier phenomenological descriptions. The observed pattern in the charm lifetime ratios is reproduced in a semi-quantitative manner as well as could be expected; as far as the beauty lifetime ratios are concerned some problems may well be emerging. The maturity level achieved in the measurements bodes quite well for future challenges where reliable and efficient tracking of the decay vertices will be crucial. (orig.)

  12. Theoretical calculations of positron lifetimes for metal oxides

    International Nuclear Information System (INIS)

    Mizuno, Masataka; Araki, Hideki; Shirai, Yasuharu

    2004-01-01

    Our recent positron lifetime measurements for metal oxides suggest that positron lifetimes of bulk state in metal oxides are shorter than previously reported values. We have performed theoretical calculations of positron lifetimes for bulk and vacancy states in MgO and ZnO using first-principles electronic structure calculations and discuss the validity of positron lifetime calculations for insulators. By comparing the calculated positron lifetimes to the experimental values, it wa found that the semiconductor model well reproduces the experimental positron lifetime. The longer positron lifetime previously reported can be considered to arise from not only the bulk but also from the vacancy induced by impurities. In the case of cation vacancy, the calculated positron lifetime based on semiconductor model is shorter than the experimental value, which suggests that the inward relaxation occurs around the cation vacancy trapping the positron. (author)

  13. Fluorescence lifetime evaluation of whole soils from the Amazon rainforest.

    Science.gov (United States)

    Nicolodelli, Gustavo; Tadini, Amanda Maria; Nogueira, Marcelo Saito; Pratavieira, Sebastião; Mounier, Stephane; Huaman, Jose Luis Clabel; Dos Santos, Cléber Hilário; Montes, Célia Regina; Milori, Débora Marcondes Bastos Pereira

    2017-08-20

    Time-resolved fluorescence spectroscopy (TRFS) is a new tool that can be used to investigate processes of interaction between metal ions and organic matter (OM) in soils, providing a specific analysis of the structure and dynamics of macromolecules. To the best of our knowledge, there are no studies in the literature reporting the use of this technique applied to whole/non-fractionated soil samples, making it a potential method for use in future studies. This work describes the use of TRFS to evaluate the fluorescence lifetimes of OM of whole soils from the Amazon region. Analysis was made of pellets of soils from an oxisol-spodosol system, collected in São Gabriel da Cachoeira (Amazonas, Brazil). The fluorescence lifetimes in the oxisol-spodosol system were attributed to two different fluorophores. One was related to complexation of an OM fraction with metals, resulting in a shorter fluorophore lifetime. A short fluorescence lifetime (2-12 ns) could be associated with simpler structures of the OM, while a long lifetime (19-66 ns) was associated with more complex OM structures. This new TRFS technique for analysis of the fluorescence lifetime in whole soil samples complies with the principles of green chemistry.

  14. Optimal Taxation and Social Insurance in a Lifetime Perspective

    DEFF Research Database (Denmark)

    Bovenberg, A. Lans; Sørensen, Peter Birch

    Advances in information technology have improved the administrative feasibility of redistribution based on lifetime earnings recorded at the time of retirement. We study optimal lifetime income taxation and social insurance in an economy in which redistributive taxation and social insurance serve...... to insure (ex ante) against skill heterogeneity as well as disability risk. Optimal disability benefits rise with previous earnings so that public transfers depend not only on current earnings but also on earnings in the past. Hence, lifetime taxation rather than annual taxation is optimal. The optimal tax...

  15. Multiphoton autofluorescence lifetime imaging of induced pluripotent stem cells

    Science.gov (United States)

    Uchugonova, Aisada

    2017-06-01

    The multiphoton fluorescence lifetime imaging tomograph MPTflex with its flexible 360-deg scan head, articulated arm, and tunable femtosecond laser source was employed to study induced pluripotent stem cell (iPS) cultures. Autofluorescence (AF) lifetime imaging was performed with 250-ps temporal resolution and submicron spatial resolution using time-correlated single-photon counting. The two-photon excited AF was based on the metabolic coenzymes NAD(P)H and flavin adenine dinucleotide/flavoproteins. iPS cells generated from mouse embryonic fibroblasts (MEFs) and cocultured with growth-arrested MEFs as feeder cells have been studied. Significant differences on AF lifetime signatures were identified between iPS and feeder cells as well as between their differentiating counterparts.

  16. Lifetime of Organic Photovoltaics: Status and Predictions

    DEFF Research Database (Denmark)

    Gevorgyan, Suren; Madsen, Morten Vesterager; Roth, Bérenger

    2016-01-01

    The results of a meta-analysis conducted on organic photovoltaics (OPV) lifetime data reported in the literature is presented through the compilation of an extensive OPV lifetime database based on a large number of articles, followed by analysis of the large body of data. We fully reveal the prog......The results of a meta-analysis conducted on organic photovoltaics (OPV) lifetime data reported in the literature is presented through the compilation of an extensive OPV lifetime database based on a large number of articles, followed by analysis of the large body of data. We fully reveal...... the progress of reported OPV lifetimes. Furthermore, a generic lifetime marker has been defi ned, which helps with gauging and comparing the performance of different architectures and materials from the perspective of device stability. Based on the analysis, conclusions are drawn on the bottlenecks...

  17. Electricite de France: Lifetime Project

    International Nuclear Information System (INIS)

    Combes, Jean-Pierre

    1991-01-01

    Electricite de France produces almost 80% of its electricity by means of standardized PWR nuclear power stations. Starting in 1986, therefore, a project known as the 'Lifetime Project' was developed, whose aim was initially to ensure that the lifetime defined at design stage (40 years in general) could be attained without major difficulty (follow up of the aging process). It then became apparent that it would be useful to know just how far it would be technically and economically possible to go. As a result, the project is now working towards increasing the lifetime of power stations. (author)

  18. Determination of the D mesons lifetimes

    International Nuclear Information System (INIS)

    Josa Mutuberria, M.I.

    1990-01-01

    The results from the experiment NA27, performed in the North Area of the Super Proton Synchrotron at CERN are presented. The experimental set up was the small, high resolution, rapid cyling bubble chamber LEBC coupled with the European Hybrid Spectrometer (EHS). More than 2 millions pictures were taken, with 1015000 in teractions in hydrogen. The stastistical sensitivity of the experiment was 38.5 events/μb. A clean sample of 700 charm particle decays was obtained. Estimators with minimal systematic and statistical errors are developed for the determination of the lifetimes of short-lived particles whose individual momenta are unknown. These estimators make use of the measured decay lengths and the a priori known production characteristics. In this way, it is possible to include identified but not fully reconstructed charm decays in the sample to determine their lifetime. The properties of these estimators were extensively studied by means of Montecarlo simulation. The detection of the short-lived particles through the impact parameter of their charged decay products leads to additional complications which are taken into account. The biases and statistical errors inherent in using simpler approximate lifetime estimators are also discussed. These estimators are applied to determine the lifetime of the D o and D +- mesons using the charm data sample from NA27. (Author)

  19. Lifetime risk of atrial fibrillation according to optimal, borderline, or elevated levels of risk factors: cohort study based on longitudinal data from the Framingham Heart Study

    Science.gov (United States)

    Staerk, Laila; Wang, Biqi; Preis, Sarah R; Larson, Martin G; Lubitz, Steven A; Ellinor, Patrick T; McManus, David D; Ko, Darae; Weng, Lu-Chen; Lunetta, Kathryn L; Frost, Lars; Benjamin, Emelia J

    2018-01-01

    Abstract Objective To examine the association between risk factor burdens—categorized as optimal, borderline, or elevated—and the lifetime risk of atrial fibrillation. Design Community based cohort study. Setting Longitudinal data from the Framingham Heart Study. Participants Individuals free of atrial fibrillation at index ages 55, 65, and 75 years were assessed. Smoking, alcohol consumption, body mass index, blood pressure, diabetes, and history of heart failure or myocardial infarction were assessed as being optimal (that is, all risk factors were optimal), borderline (presence of borderline risk factors and absence of any elevated risk factor), or elevated (presence of at least one elevated risk factor) at index age. Main outcome measure Lifetime risk of atrial fibrillation at index age up to 95 years, accounting for the competing risk of death. Results At index age 55 years, the study sample comprised 5338 participants (2531 (47.4%) men). In this group, 247 (4.6%) had an optimal risk profile, 1415 (26.5%) had a borderline risk profile, and 3676 (68.9%) an elevated risk profile. The prevalence of elevated risk factors increased gradually when the index ages rose. For index age of 55 years, the lifetime risk of atrial fibrillation was 37.0% (95% confidence interval 34.3% to 39.6%). The lifetime risk of atrial fibrillation was 23.4% (12.8% to 34.5%) with an optimal risk profile, 33.4% (27.9% to 38.9%) with a borderline risk profile, and 38.4% (35.5% to 41.4%) with an elevated risk profile. Overall, participants with at least one elevated risk factor were associated with at least 37.8% lifetime risk of atrial fibrillation. The gradient in lifetime risk across risk factor burden was similar at index ages 65 and 75 years. Conclusions Regardless of index ages at 55, 65, or 75 years, an optimal risk factor profile was associated with a lifetime risk of atrial fibrillation of about one in five; this risk rose to more than one in three in individuals with at least

  20. Study of positron lifetime spectrum for Zn O varistor ceramics fabricated by Sol-gel route

    International Nuclear Information System (INIS)

    Li Xigui; Wei Shutao; Zhang Ruiying; Cheng Guosheng; Dai Xianqi; Zhang Jincang; Xing Huaimin

    2000-01-01

    An investigation of positron lifetime spectrum for ZnO varistor ceramics fabricated by Sol-gel route was carried out. The relationship between lifetime parameters and the densification and nonlinear coefficient α was given. The dependence of electrical properties on sintering temperature and duration was discussed

  1. Lifetime of charge carriers in intrinsic indium antimonide

    International Nuclear Information System (INIS)

    Bruhns, H.; Kruse, H.

    1980-01-01

    The lifetime of additional photoinjected electron-hole pairs in intrinsic InSb at 291 K is investigated by measuring the photoconductive (PC) decay. Apart from studying the usual PC-decay an arangement is used with superimposed magnetic field transverse to the electric field. Depending on the direction of the magnetic field the photoinjected plasma is either driven into the sample's bulk or travels parallel to the illuminated surface. The Auger-lifetime is evaluated from the measurements by a numerical magnetohydrodynamical simulation taking into account surface recombination as well as the Suhl profile of the intrinsic plasma. A lifetime of tau = (57+-3) ns is found which is independent of the magnetic field up to 2.3 T. (author)

  2. Status of PPI (Pohang Photo-Injector) for PAL XFEL

    CERN Document Server

    Park, Sung-Ju; Oh, Jong-Seok; Park, Chong-Do; Park Jang Ho; Soo Ko In; Wang, Xijie; Woon Parc, Yong

    2005-01-01

    A X-Ray Free Electron Laser (XFEL) project based on the Self-Amplified Spontaneous Emission (SASE) is under progress at the Pohang Accelerator Laboratory (PAL). One of the critical R&D for the PAL XFEL* is to develop the Pohang Photo-Injector (PPI) which is required to deliver electron beams with normalized emittance < 1.5 mm-mrad. In order to achieve the required beam quality with high stability and reliability, we will use photocathode with quantum efficiency > 0.1 % and long lifetime. This will greatly lessen the laser energy requirement for producing flat-top UV pulses, and open the possibility of using only regenerative amplifiers (RGAs) to drive the photocathode RF gun. The RGAs can produce mJs output with much better stability than multi-pass amplifiers. Both the Cs2Te and Mg are under consideration for the possible photo-cathode. To demonstrate the suitability of the Mg and Cs2Te for the future 4th generation light source application, an improved BNL-type S-band RF gun with a high-pe...

  3. Measurements and Studies of Secondary Electron Emission of Diamond Amplified Photocathode

    Energy Technology Data Exchange (ETDEWEB)

    Wu,Q.

    2008-10-01

    The Diamond Amplified Photocathode (DAP) is a novel approach to generating electrons. By following the primary electron beam, which is generated by traditional electron sources, with an amplifier, the electron beam available to the eventual application is increased by 1 to 2 orders of magnitude in current. Diamond has a very wide band gap of 5.47eV which allows for a good negative electron affinity with simple hydrogenation, diamond can hold more than 2000MV/m field before breakdown. Diamond also provides the best rigidity among all materials. These two characters offer the capability of applying high voltage across very thin diamond film to achieve high SEY and desired emission phase. The diamond amplifier also is capable of handling a large heat load by conduction and sub-nanosecond pulse input. The preparation of the diamond amplifier includes thinning and polishing, cleaning with acid etching, metallization, and hydrogenation. The best mechanical polishing available can provide high purity single crystal diamond films with no less than 100 {micro}m thickness and <15 nm Ra surface roughness. The ideal thickness for 700MHz beam is {approx}30 {micro}m, which requires further thinning with RIE or laser ablation. RIE can achieve atomic layer removal precision and roughness eventually, but the time consumption for this procedure is very significant. Laser ablation proved that with <266nm ps laser beam, the ablation process on the diamond can easily achieve removing a few microns per hour from the surface and <100nm roughness. For amplifier application, laser ablation is an adequate and efficient process to make ultra thin diamond wafers following mechanical polishing. Hydrogenation will terminate the diamond surface with monolayer of hydrogen, and form NEA so that secondary electrons in the conduction band can escape into the vacuum. The method is using hydrogen cracker to strike hydrogen atoms onto the bare diamond surface to form H-C bonds. Two independent

  4. Time Dependent Quantum Efficiency and Dark Current Measurements in an RF Photocathode Injector with a High Quantum Efficiency Cathode

    CERN Document Server

    Fliller, Raymond P; Hartung, Walter

    2005-01-01

    A system was developed at INFN Milano for preparing cesium telluride photo-cathodes and transferring them into an RF gun under ultra-high vacuum. This system has been in use at the Fermilab NICADD Photo-Injector Laboratory (FNPL) since 1997. A similar load-lock system is used at the TeSLA Test Facility at DESY-Hamburg. Two 1.625-cell high duty cycle RF guns have been fabricated for the project. Studies of the photo-emission and field emission ("dark current") behavior of both RF guns have been carried out. Unexpected phenomena were observed in one of the RF guns. In situ changes in the cathode's quantum efficiency and dark current with time were seen during operation of the photo-injector. These changes were correlated with the magnetostatic field at the cathode.* In addition, multipacting is observed in the RF guns under certain conditions. Recent measurements indicate a correlation between multipacting, anomalous photo-emission behavior, and anomalous field emission behavior. Results will be presented.

  5. Lifetime Improvement by Battery Scheduling

    NARCIS (Netherlands)

    Jongerden, M.R.; Schmitt, Jens B.; Haverkort, Boudewijn R.H.M.

    The use of mobile devices is often limited by the lifetime of their batteries. For devices that have multiple batteries or that have the option to connect an extra battery, battery scheduling, thereby exploiting the recovery properties of the batteries, can help to extend the system lifetime. Due to

  6. Beam dynamics studies of a 30 MeV RF linac for neutron production

    Science.gov (United States)

    Nayak, B.; Krishnagopal, S.; Acharya, S.

    2018-02-01

    Design of a 30 MeV, 10 Amp RF linac as neutron source has been carried out by means of ASTRA simulation code. Here we discuss details of design simulations for three different cases i.e Thermionic , DC and RF photocathode guns and compare them as injectors to a 30 MeV RF linac for n-ToF production. A detailed study on choice of input parameters of the beam from point of view of transmission efficiency and beam quality at the output have been described. We found that thermionic gun isn't suitable for this application. Both DC and RF photocathode gun can be used. RF photocathode gun would be of better performance.

  7. Lifetime measurements in the picosecond range: Achievements and Perspectives

    International Nuclear Information System (INIS)

    Kruecken, Reiner

    1999-01-01

    This contribution will review the recoil distance method (RDM), its current range of applications as well as future perspectives for the measurement of lifetimes in the picosecond range of excited nuclear levels. Recent Doppler-shift lifetime experiments with large gamma-ray spectrometers have achieved a new level of precision and sensitivity, providing new insights into nuclear structure physics. High precision RDM measurements of near-yrast states in various mass regions have revealed dynamic shape effects beyond the framework of collective models and have also allowed to study the interaction between coexisting shapes. The measurement of lifetimes in superdeformed bands has shown that lifetimes can be measured for nuclear excitations, which are only populated with a few percent of the production cross-section of a nucleus. These experiments have also enabled us to study the mechanism of the decay-out of superdeformed bands. Another example for the need of precise lifetime measurements is the recent verifications of the concept of 'magnetic rotation' in nuclei by the experimental observation of the characteristic drop of B(M1) values as a function of angular momentum. These recent breakthroughs have also opened new perspectives for the use of the RDM technique for more exotic regions of nuclei and nuclear excitations. Here the measurement of lifetimes in neutron rich nuclei, which are not accessible with conventional nuclear reactions using stable beams and targets, is of special interest. Possible experimental approaches and simple estimates for the feasibility of such experiments will be presented. (author)

  8. CEBAF 200 kV Inverted Electron Gun

    International Nuclear Information System (INIS)

    Grames, J.M.; Adderley, P.A.; Clark, J.; Hansknecht, J.; Poelker, M.; Stutzman, M.L.; Suleiman, R.; Surles-Law, K.E.L.

    2011-01-01

    Two DC high voltage GaAs photoguns have been built at Jefferson Lab based on a compact inverted insulator design. One photogun provides the polarized electron beam at CEBAF and operates at 130 kV bias voltage. The other gun is used for high average current lifetime studies at a dedicated test facility and has been operated at bias voltage up to 225 kV. The advantages of higher DC voltage for CEBAF include reduced space-charge emittance growth and the potential for prolonged photocathode lifetime. However, a consequence of operating at higher voltages is the increased likelihood of field emission or breakdown, both of which are unacceptable. Highlights of the R and D studies leading toward a production 200keV GaAs photogun for CEBAF will be presented.

  9. Autofluorescence lifetime imaging during transoral robotic surgery: a clinical validation study of tumor detection (Conference Presentation)

    Science.gov (United States)

    Lagarto, João. L.; Phipps, Jennifer E.; Unger, Jakob; Faller, Leta M.; Gorpas, Dimitris; Ma, Dinglong M.; Bec, Julien; Moore, Michael G.; Bewley, Arnaud F.; Yankelevich, Diego R.; Sorger, Jonathan M.; Farwell, Gregory D.; Marcu, Laura

    2017-02-01

    Autofluorescence lifetime spectroscopy is a promising non-invasive label-free tool for characterization of biological tissues and shows potential to report structural and biochemical alterations in tissue owing to pathological transformations. In particular, when combined with fiber-optic based instruments, autofluorescence lifetime measurements can enhance intraoperative diagnosis and provide guidance in surgical procedures. We investigate the potential of a fiber-optic based multi-spectral time-resolved fluorescence spectroscopy instrument to characterize the autofluorescence fingerprint associated with histologic, morphologic and metabolic changes in tissue that can provide real-time contrast between healthy and tumor regions in vivo and guide clinicians during resection of diseased areas during transoral robotic surgery. To provide immediate feedback to the surgeons, we employ tracking of an aiming beam that co-registers our point measurements with the robot camera images and allows visualization of the surgical area augmented with autofluorescence lifetime data in the surgeon's console in real-time. For each patient, autofluorescence lifetime measurements were acquired from normal, diseased and surgically altered tissue, both in vivo (pre- and post-resection) and ex vivo. Initial results indicate tumor and normal regions can be distinguished based on changes in lifetime parameters measured in vivo, when the tumor is located superficially. In particular, results show that autofluorescence lifetime of tumor is shorter than that of normal tissue (p robot assisted cancer removal interventions.

  10. Quantum system lifetimes and measurement perturbations

    International Nuclear Information System (INIS)

    Najakov, E.

    1977-05-01

    The recently proposed description of quantum system decay in terms of repeated measurement perturbations is modified. The possibility of retarded reductions to a unique quantum state, due to ineffective localization of the decay products at initial time measurements, is simply taken into account. The exponential decay law is verified again. A modified equation giving the observed lifetime in terms of unperturbed quantum decay law, measurement frequency and reduction law is derived. It predicts deviations of the observed lifetime from the umperturbed one, together with a dependence on experimental procedures. The influence of different model unperturbed decay laws and reduction laws on this effect is studied

  11. Measurement of the $\\Omega_{c}^{0}$ lifetime

    CERN Document Server

    Adamovich, M.I.; Alexandrov, Yu.A.; Barberis, D.; Beck, M.; Berat, C.; Beusch, W.; Boss, M.; Brons, S.; Bruckner, W.; Buenerd, M.; Buscher, C.; Charignon, F.; Chauvin, J.; Chudakov, E.A.; Dropmann, F.; Engelfried, J.; Faller, F.; Fournier, A.; Gerasimov, S.; Godbersen, M.; Grafstrom, P.; Haller, T.; Heidrich, M.; Hurst, R.B.; Konigsmann, Kay; Konorov, I.; Martens, K.; Martin, P.; Masciocchi, S.; Michaels, R.; Muller, U.; Newsom, C.; Paul, S.; Povh, B.; Ren, Z.; Rey-Campagnolle, M.; Rosner, G.; Rossi, L.; Rudolph, H.; Schmitt, L.; Siebert, H.W.; Simon, A.; Smith, V.J.; Thilmann, O.; Trombini, A.; Vesin, E.; Volkemer, B.; Vorwalter, K.; Walcher, T.; Walder, G.; Werding, R.; Wittmann, E.; Zavertyaev, M.V.

    1995-01-01

    We present the measurement of the lifetime of the Omega_c we have performed using three independent data samples from two different decay modes. Using a Sigma- beam of 340 GeV/c we have obtained clean signals for the Omega_c decaying into Xi- K- pi+ pi+ and Omega- pi+ pi- pi+, avoiding topological cuts normally used in charm analysis. The short but measurable lifetime of the Omega_c is demonstrated by a clear enhancement of the signals at short but finite decay lengths. Using a continuous maximum likelihood method we determined the lifetime to be tau(Omega_c) = 55 +13-11(stat) +18-23(syst) fs. This makes the Omega_c the shortest living weakly decaying particle observed so far. The short value of the lifetime confirms the predicted pattern of the charmed baryon lifetimes and demonstrates that the strong interaction plays a vital role in the lifetimes of charmed hadrons.

  12. Lifetime improvement by battery scheduling

    NARCIS (Netherlands)

    Jongerden, M.R.; Haverkort, Boudewijn R.H.M.

    The use of mobile devices is often limited by the lifetime of its battery. For devices that have multiple batteries or that have the option to connect an extra battery, battery scheduling, thereby exploiting the recovery properties of the batteries, can help to extend the system lifetime. Due to the

  13. Positron lifetime spectroscopy of internally oxidised Ag-In alloys

    International Nuclear Information System (INIS)

    Wegner, D.; Lieb, K.P.

    1989-01-01

    The effects of In 2 O 3 precipitates on positron lifetimes after internal oxidation of α-Ag-In alloys have been investigated. A positron trap associated with the lifetime τ 205(3) ps was detected. On the basis of the experimental results obtained for different oxidation kinetics parameters, a trapping model is proposed according to which positrons thermalised in a dislocation field around oxide precipitates are trapped at the oxide/metal phase boundary. The transition from internal to external oxidation of Ag-In was also studied. The positron lifetime in In 2 O 3 was measured to be τ = 263(8) ps. (author)

  14. Positron annihilation lifetime studies of sol-gel transition of carrageenan gels

    International Nuclear Information System (INIS)

    Wakabayashi, Y.; Ito, K.; Li, H.L.; Ujihara, Y.

    1996-01-01

    Positron annihilation lifetime measurement was applied to study the sol-gel transition of anionic polysaccharide aqueous solutions in terms of free-volume parameters the size, intensity, and size distribution of free volumes of the gelation of K-form κ-carrageenan solutions as a function of temperature. Slight variations of free volume size and intensity against temperature were observed near 295 K. The correlation of free-volume data with other physical properties vibrational spectra (IR and Raman), conductivity, SAXS, elastic measurement, differential scanning calorimetry were investigated to understand the mechanism of sol-gel transition of carrageenan. (author)

  15. Lifetime depression history and sexual function in women at midlife.

    Science.gov (United States)

    Cyranowski, Jill M; Bromberger, Joyce; Youk, Ada; Matthews, Karen; Kravitz, Howard M; Powell, Lynda H

    2004-12-01

    We examined the association between lifetime depression history and sexual function in a community-based sample of midlife women. Specifically, 914 women aged 42-52 who were participants in the Study of Women's Health Across the Nation completed a self-report assessment of their sexual behaviors, sexual desire, sexual arousal, and sexual satisfaction over the past 6 months. On the basis of the Structured Clinical Interview for the DSM-IV , participants were categorized into 1 of 3 lifetime major depressive disorder (MDD) history groups: no MDD history, single episode MDD, and recurrent MDD. In line with previous reports, women with a history of recurrent MDD reported experiencing less frequent sexual arousal, less physical pleasure, and less emotional satisfaction within their current sexual relationships. Although the groups did not differ in their reported frequency of sexual desire or partnered sexual behaviors, lifetime depression history was associated with increased rates of self-stimulation (masturbation). Associations between lifetime depression history and lower levels of physical pleasure within partnered sexual relationships and higher rates of masturbation remained significant following control for current depressive symptoms, study site, marital status, psychotropic medication use, and lifetime history of anxiety or substance abuse/dependence disorder. Future research is needed to characterize the temporal and etiologic relationships among lifetime depressive disorder, current mood state, and sexual function in women across the lifespan.

  16. Positron lifetime calculation for the elements of the periodic table.

    Science.gov (United States)

    Campillo Robles, J M; Ogando, E; Plazaola, F

    2007-04-30

    Theoretical positron lifetime values have been calculated systematically for most of the elements of the periodic table. Self-consistent and non-self-consistent schemes have been used for the calculation of the electronic structure in the solid, as well as different parametrizations for the positron enhancement factor and correlation energy. The results obtained have been studied and compared with experimental data, confirming the theoretical trends. As is known, positron lifetimes in bulk show a periodic behaviour with atomic number. These calculations also confirm that monovacancy lifetimes follow the same behaviour. The effects of enhancement factors used in calculations have been commented upon. Finally, we have analysed the effects that f and d electrons have on positron lifetimes.

  17. Positron lifetime calculation for the elements of the periodic table

    International Nuclear Information System (INIS)

    Robles, J M Campillo; Ogando, E; Plazaola, F

    2007-01-01

    Theoretical positron lifetime values have been calculated systematically for most of the elements of the periodic table. Self-consistent and non-self-consistent schemes have been used for the calculation of the electronic structure in the solid, as well as different parametrizations for the positron enhancement factor and correlation energy. The results obtained have been studied and compared with experimental data, confirming the theoretical trends. As is known, positron lifetimes in bulk show a periodic behaviour with atomic number. These calculations also confirm that monovacancy lifetimes follow the same behaviour. The effects of enhancement factors used in calculations have been commented upon. Finally, we have analysed the effects that f and d electrons have on positron lifetimes

  18. Effect of the final-state interaction on the initial core-hole lifetime: the case of the 4s-hole lifetime of Sn metal

    International Nuclear Information System (INIS)

    Ohno, Masahide

    2003-01-01

    The first theoretical study of the effect of the final-state interaction on the initial core-hole lifetime is presented. The 4s-hole lifetime width of Sn metal is calculated by an ab-initio atomic many-body theory (Green's function method). When the final-state interaction in the 4p4d two-hole state, created by the 4s -1 -4p -1 4d -1 εf super Coster-Kronig (CK) transition of the initial 4s hole, is explicitly taken into account, the ab-initio atomic many-body calculation of the 4s-hole X-ray photoelectron spectroscopy (XPS) spectrum of Sn atom can provide excellent agreement with experiment in both the 4s-hole energy and the 4s-hole lifetime width. Otherwise, the many-body calculation underestimates considerably the 4s-hole lifetime width. The 4p4d two-hole state interacts strongly with the 4d triple-hole state by the 4p -1 4d -1 -4d -3 εf super CK transition. The interaction affects greatly the initial 4s-hole lifetime width

  19. Quantum lifetime in electron storage rings

    International Nuclear Information System (INIS)

    Chao, A.W.

    1977-02-01

    One of the mechanisms which contribute to beam lifetime in electron storage rings is the quantum emission of energetic photons causing particles to be lost from the rf bucket. This quantum lifetime is among other things important in defining the required aperture in a storage ring. An approximate expression of quantum lifetime, predicted by a one-dimensional model which takes into account only the betatron motion, has been used in most storage ring designs. If the beam is aperture-limited at a position with nonzero dispersion, both the betatron and synchrotron motions have to be included and a two-dimensional model must be used. An exact expression of quantum lifetime for the one-dimensional case and an approximate expression for the two-dimensional case are given

  20. Quantum lifetime in electron storage rings

    International Nuclear Information System (INIS)

    Chao, A.W.

    1977-01-01

    One of the mechanisms which contributes to beam lifetime in electron storage rings is the quantum emission of energetic photons causing particles to be lost from the rf bucket. This quantum lifetime is among other things important in defining the required aperture in a storage ring. An approximate expression of quantum lifetime, predicted by a one-dimensional model which takes into account only the betatron motion, has been used in most storage ring designs. If the beam is aperture-limited at a position with nonzero dispersion, both the betatron and synchrotron motions have to be included, and a two-dimensional model must be used. An exact expression of quantum lifetime for the one-dimensional case and an approximate expression for the two-dimensional case are given

  1. Application of positron annihilation lifetime technique for {gamma}-irradiation stresses study in chalcogenide vitreous semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Shpotyuk, O.; Golovchak, R.; Kovalskiy, A. [Scientific Research Company ' ' Carat' ' , Stryjska str. 20279031 Lviv (Ukraine); Filipecki, J.; Hyla, M. [Physics Institute, Pedagogical University, Al. Armii Krajowej 13/1542201 Czestochowa (Poland)

    2002-08-01

    The influence of {gamma}-irradiation on the positron annihilation lifetime spectra in chalcogenide vitreous semiconductors of As-Ge-S system has been analysed. The correlations between lifetime data, structural features and chemical compositions of glasses have been discussed. The observed lifetime components are connected with bulk positron annihilation and positron annihilation on various native and {gamma}-induced open volume defects. It is concluded that after {gamma}-irradiation of investigated materials the {gamma}-induced microvoids based on S{sub 1}{sup -}, As{sub 2}{sup -}, and Ge{sub 3}{sup -} coordination defects play the major role in positron annihilation processes. (Abstract Copyright[2002], Wiley Periodicals, Inc.)

  2. Inequivalence of single-particle and population lifetimes in a cuprate superconductor

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Shuolong [SLAC National Accelerator Lab., Menlo Park, CA (United States); Stanford Univ., Stanford, CA (United States); Sobota, J. A. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Leuenberger, D. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Stanford Univ., Stanford, CA (United States); He, Y. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Stanford Univ., Stanford, CA (United States); Hashimoto, M. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Lu, D. H. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Eisaki, H. [National Institute of Advanced Industrial Science and Technology, Ibaraki (Japan); Kirchmann, P. S. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Shen, Z. -X. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Stanford Univ., Stanford, CA (United States)

    2015-06-15

    We study optimally doped Bi-2212 (Tc=96 K) using femtosecond time- and angle-resolved photoelectron spectroscopy. Energy-resolved population lifetimes are extracted and compared with single-particle lifetimes measured by equilibrium photoemission. The population lifetimes deviate from the single-particle lifetimes in the low excitation limit by 1–2 orders of magnitude. Fundamental considerations of electron scattering unveil that these two lifetimes are in general distinct, yet for systems with only electron-phonon scattering they should converge in the low-temperature, low-fluence limit. As a result, the qualitative disparity in our data, even in this limit, suggests that scattering channels beyond electron-phonon interactions play a significant role in the electron dynamics of cuprate superconductors.

  3. Study of creep-fatigue behavior in a 1000 MW rotor using a phenomenological lifetime model

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Nailong; Wang, Weizhe; Jiang, Jishen; Liu, Yingzheng [School of Mechanical Engineering, Shanghai (China)

    2017-02-15

    In this study, the phenomenological lifetime model was applied to part of an ultra-supercritical steam turbine rotor model to predict its lifetime as a post processing of the finite element method. To validate the accuracy and adaptation of the post processing program, stress strain hysteresis loops of a cylinderal model under service-like load cycle conditions in cycle N = 1 and 300 were constructed, and the comparison of the results with experimental data on the same cylinderal specimen showed them to be satisfactory. The temperature and von Mises stress distributions of the rotor during a startup-running-shutdown-natural cool process were numerically studied using ABAQUS and the damage caused by the interaction of creep and fatigue was subsequently computed and discussed. It was found that the maximum damage appeared at the inlet notch zone, with the blade groove areas and the front notch areas also suffering a large damage amplitude.

  4. Theoretical insights into the minority carrier lifetime of doped Si—A computational study

    Science.gov (United States)

    Iyakutti, K.; Lavanya, R.; Rajeswarapalanichamy, R.; Mathan Kumar, E.; Kawazoe, Y.

    2018-04-01

    Using density functional theory, we have analyzed the ways and means of improving the minority carrier lifetime (MCL) by calculating the band structure dependent quantities contributing to the MCL. We have computationally modeled silicon doped with different elements like B, C, N, O, P, Ti, Fe, Ga, Ge, As, In, Sn, Sb, and Pt and looked at the effect of doping on MCL. In co-doping, the systems Si-B-Ga, Si-B-Ge, Si-B-2Ge, Si-B-Pt, Si-Ga-Ge, Si-Ga-2Ge, and Si-Ga-Pt are investigated. From our calculation, it is found that by doping and co-doping of Si with suitable elements having "s" and "p" electrons, there is a decrease in the recombination activity. The predicted effective minority carrier lifetime indicates the possibility of significant improvements. Based on the above studies, it is now maybe possible, with suitable choice of dopant and co-dopant material, to arrive at part of a standard production process for solar grade Si material.

  5. Quantum efficiency of cesium iodide photocathodes in the 120-220 nm spectral range traceable to a primary detector standard

    CERN Document Server

    Rabus, H; Richter, M; Ulm, G; Friese, J; Gernhäuser, R; Kastenmüller, A; Maier-Komor, P; Zeitelhack, K

    1999-01-01

    Differently prepared CsI samples have been investigated in the 120-220 nm spectral range for their quantum efficiency, spatial uniformity and the effect of radiation aging. The experiments were performed at the PTB radiometry laboratory at the Berlin synchrotron radiation facility BESSY. A calibrated GaAsP Schottky photodiode was used as transfer detector standard to establish traceability to the primary detector standard, because this type of photodiode - unlike silicon p-on-n photodiodes - proved to be of sufficiently stable response when exposed to vacuum ultraviolet radiation. The paper reviews the experimental procedures that were employed to characterize and calibrate the GaAsP photodiode and reports the results that were obtained on the investigated CsI photocathodes.

  6. Lifetime value in business process

    Directory of Open Access Journals (Sweden)

    Martin Souček

    2011-01-01

    Full Text Available The paper focuses on lifetime value assessment and its implementation and application in business processes. The lifetime value is closely connected to customer relationship management. The paper presents results of three consecutive researches devoted to issues of customer relationship management. The first two from 2008 and 2010 were conducted as quantitative ones; the one from 2009 had qualitative nature. The respondents were representatives of particular companies. The means for data collection was provided by ReLa system. We will focus on individual attributes of lifetime value of a customer, and relate them to approaches of authors mentioned in introduction. Based on the qualitative research data, the paper focuses on individual customer lifetime value parameters. These parameters include: the cost to the customer relationship acquisition and maintenance, profit generated from a particular customer, customer awareness value, the level of preparedness to adopt new products, the value of references and customer loyalty level. For each of these parameters, the paper provides specific recommendations. Moreover, it is possible to learn about the nature of these parameter assessments in the Czech environment.

  7. Models for Battery Reliability and Lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Smith, K.; Wood, E.; Santhanagopalan, S.; Kim, G. H.; Neubauer, J.; Pesaran, A.

    2014-03-01

    Models describing battery degradation physics are needed to more accurately understand how battery usage and next-generation battery designs can be optimized for performance and lifetime. Such lifetime models may also reduce the cost of battery aging experiments and shorten the time required to validate battery lifetime. Models for chemical degradation and mechanical stress are reviewed. Experimental analysis of aging data from a commercial iron-phosphate lithium-ion (Li-ion) cell elucidates the relative importance of several mechanical stress-induced degradation mechanisms.

  8. Neutron lifetime and generation time by KENO IV

    International Nuclear Information System (INIS)

    Hayashi, Masatoshi

    1991-01-01

    It is believed that Monte Carlo method is suitable to the calculation of neutron lifetime and generation time with reference to the life cycle viewpoint. This paper illustrates that those times obtained by Monte Carlo method are quite different from the results by perturbation method. The neutron lifetime and the generation time for bare and reflected reactors were investigated by the Monte Carlo program, KENO IV. the Monte Carlo procedure is based on tracking and recording the life history of neutrons in a realistic fashion in a fissionable system with minimum nuclear and geometric approximations. The KENO IV provides the multiplication factor, neutron lifetime and generation time simultaneously. The thermal spherical reactors for both bare and reflected reactors were studied using the KENO IV. The reflected reactor is surrounded with 30 cm thick light water. The atomic densities in the regions and the calculated results of the multiplication factor, neutron lifetime and generation time are given. The different definitions of these times between the Monte Carlo method and perturbation theory caused the difference of the results. (K.I.)

  9. CO sub 2 absorption of perovskites as seen by positron lifetime spectroscopy

    CERN Document Server

    Suevegh, K; Juhasz, G; Homonnay, Z; Vertes, A

    2000-01-01

    The CO sub 2 absorption of several ABO sub 3 type perovskites was studied by positron lifetime spectroscopy. The longer positron lifetime was associated with positrons trapped by A site vacancies. The evaluated positron lifetime data indicated the relative stability of the crystal structure of Sr(Co sub 0 sub . sub 5 Fe sub 0 sub . sub 5)O sub 3 sub - subdelta against Ca doping at low Ca concentrations. Oxygen desorption and CO sub 2 absorption/desorption could also be followed by positron lifetime spectroscopy. It was shown that the concentration of oxygen vacancies has a large effect on positron lifetime data through the electron density of A site vacancies.

  10. Lifetime Economic Burden of Rape Among U.S. Adults.

    Science.gov (United States)

    Peterson, Cora; DeGue, Sarah; Florence, Curtis; Lokey, Colby N

    2017-06-01

    This study estimated the per-victim U.S. lifetime cost of rape. Data from previous studies was combined with current administrative data and 2011 U.S. National Intimate Partner and Sexual Violence Survey data in a mathematical model. Rape was defined as any lifetime completed or attempted forced penetration or alcohol- or drug-facilitated penetration, measured among adults not currently institutionalized. Costs included attributable impaired health, lost productivity, and criminal justice costs from the societal perspective. Average age at first rape was assumed to be 18 years. Future costs were discounted by 3%. The main outcome measures were the average per-victim (female and male) and total population discounted lifetime cost of rape. Secondary outcome measures were marginal outcome probabilities among victims (e.g., suicide attempt) and perpetrators (e.g., incarceration) and associated costs. Analysis was conducted in 2016. The estimated lifetime cost of rape was $122,461 per victim, or a population economic burden of nearly $3.1 trillion (2014 U.S. dollars) over victims' lifetimes, based on data indicating >25 million U.S. adults have been raped. This estimate included $1.2 trillion (39% of total) in medical costs; $1.6 trillion (52%) in lost work productivity among victims and perpetrators; $234 billion (8%) in criminal justice activities; and $36 billion (1%) in other costs, including victim property loss or damage. Government sources pay an estimated $1 trillion (32%) of the lifetime economic burden. Preventing sexual violence could avoid substantial costs for victims, perpetrators, healthcare payers, employers, and government payers. These findings can inform evaluations of interventions to reduce sexual violence. Published by Elsevier Inc.

  11. Masses of charmed particles, decay modes and lifetimes

    International Nuclear Information System (INIS)

    Vajsenberg, A.O.

    1982-01-01

    Basic characteristics of charmed particles obtained up to the middle of 1981 are discussed in the survey. Stated in brief are main predictions of the theory on charmed particles properties. Experimental data on masses, decay modes and lifetimes of D and F mesons as well as charmed baryons are considered. Basic experiments are described. It is pointed out that in the experiments single and pair production events as well as charmed particle decay have been observed. The charmed particles lifetime lies within the limits of 10 -12 - 10 -13 C. The lifetime of D +- mesons is approximately three times longer than the D 0 mesons lifetime. The lifetime of F mesons and Λsub(e) baryons is close to D 0 mesons lifetime [ru

  12. Lifetime abuse and perceived social support among the elderly: a study from seven European countries.

    Science.gov (United States)

    Eslami, Bahareh; Di Rosa, Mirko; Barros, Henrique; Stankunas, Mindaugas; Torres-Gonzalez, Francisco; Ioannidi-Kapolou, Elisabeth; Lindert, Jutta; Melchiorre, Maria Gabriella

    2017-08-01

    Being a victim of abuse during one's life course may affect social relations in later life. The aims of this study were to: (i) examine the association between lifetime abuse and perceived social support and (ii) identify correlates of perceived social support among older persons living in seven European countries. A sample of 4467 women and men aged 60-84 years living in Germany, Greece, Italy, Lithuania, Portugal, Spain and Sweden was collected through a cross-sectional population-based study. Abuse (psychological, physical, sexual, financial and injury) was assessed through interviews or interviews/self-response questionnaire based on the Conflict Tactics Scale-2 and the UK study on elder abuse. Perceived social support was assessed by the Multidimensional Scale of Perceived Social Support. Victims of lifetime abuse perceived poorer social support in later life. Multivariate analyses showed that high levels of perceived social support were associated with being from Greece and Lithuania (compared to Germany), being female, not living alone, consuming alcohol and physical activity. Poorer perceived social support was associated with being from Portugal, being old, having social benefits as the main source of income, experiencing financial strain and being exposed to lifetime psychological abuse and injuries. Our findings showed that exposure to psychological abuse and injuries across the lifespan were associated with low levels of perceived social support, emphasizing the importance of detection and appropriate treatment of victims of abuse during their life course. Future research should focus on coping strategies buffering the negative effects of abuse on social relationships. © The Author 2017. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  13. Reactor pressure vessel embrittlement of NPP borssele: Design lifetime and lifetime extension

    International Nuclear Information System (INIS)

    Blom, F.J.

    2007-01-01

    Embrittlement of the reactor pressure vessel of the Borssele nuclear power plant has been investigated taking account of the design lifetime of 40 years and considering 20 years subsequent lifetime extension. The paper presents the current licensing status based on considerations of material test data and of US nuclear regulatory standards. Embrittlement status is also evaluated against German and French nuclear safety standards. Results from previous fracture toughness and Charpy tests are investigated by means of the Master curve toughness transition approach. Finally, state of the art insights are investigated by means of literature research. Regarding the embrittlement status of the reactor pressure vessel of Borssele nuclear power plant it is concluded that there is a profound basis for the current license up to the original end of the design life in 2013. The embrittlement temperature changes only slightly with respect to the acceptance criterion adopted postulating further operation up to 2033. Continued safe operation and further lifetime extension are therefore not restricted by reactor pressure vessel embrittlement

  14. Luminescence and transient lifetime studies for energy transfer of PbS QD films

    Science.gov (United States)

    Wang, Joanna S.; Ullrich, Bruno; Dass, Chandriker K.; Das, Anirban; Wai, Chien M.; Brown, Gail J.; Hendrickson, Joshua R.

    2017-08-01

    Quantum confined semiconductor materials in colloidal form have drawn great attention in scientific communities due to the size-tunability, which controls their optical properties. PbS quantum dots (QDs) are exciting candidates for quantum optics, particularly due to the control of the QD sizes during the synthetic process enabling the realization of precisely tunable emission properties in the near-infrared region. Differently sized pairs of PbS QDs were deposited onto glass substrates to form thin films using supercritical CO2 (sc-CO2) deposition and solvent deposition methods (SDM). The fluorescence and photoluminescence (PL) spectra obtained from these closely packed films prepared by the sc-CO2 method reveal effective Förster resonance energy transfer (FRET) between two different sized dots, while the films composed of three different QD sizes show an even more effective FRET from the smallest to the largest ones. Energy transfer can be observed more directly by temporally resolved PL decay of mixed dots. By means of transient lifetime measurements, a mixed PbS film with 3.1 and 4.7 nm QDs was studied for FRET by time correlated single photon counting. The PL peak of the 3.1 nm QDs is quenched with respect to the emission of the 4.7 nm QDs and decays faster, and the best fit for the lifetime (decay constant)-1 is a biexponential decay mode. The long wavelength decay (4.7 nm QDs) is best fit by a mono-exponential equation. More theoretical and experimental work is required for a thorough understanding of the radiative lifetimes of PbS QDs in mixed QD systems.

  15. High spin study and lifetime measurements of neutron rich Co isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Regan, P H; Arrison, J W; Huttmeier, U J; Balamuth, D P [Pennsylvania Univ., Philadelphia, PA (United States). Dept. of Physics

    1992-08-01

    The neutron rich nuclei {sup 61,63}Co have been studied using the reactions {sup 16}O({sup 48}Ca,p2n){sup 61}Co at 110 MeV and {sup 18}O({sup 48}Ca,p2n){sup 63}Co at 110 MeV respectively. Discrete lines from the channels of interest were investigated using pre-scaled {gamma} singles, charged-particle-{gamma}, neutron-charged-particle-{gamma} and charged particle-{gamma}-{gamma} data. Decay schemes, with level spins deduced from angular distribution data are presented together with preliminary information on the lifetimes of some higher excitation states. These data represent the first study on the medium to high spin states in these nuclei. (author). 9 refs., 1 tab., 4 figs.

  16. Contactless Spectral-dependent Charge Carrier Lifetime Measurements in Silicon Photovoltaic Materials

    Science.gov (United States)

    Roller, John; Hamadani, Behrang; Dagenais, Mario

    Charge carrier lifetime measurements in bulk or unfinished photovoltaic (PV) materials allow for a more accurate estimate of power conversion efficiency in completed solar cells. In this work, carrier lifetimes in PV-grade silicon wafers are obtained by way of quasi-steady state photoconductance measurements. These measurements use a contactless RF system coupled with varying narrow spectrum input LEDs, ranging in wavelength from 460 nm to 1030 nm. Spectral dependent lifetime measurements allow for determination of bulk and surface properties of the material, including the intrinsic bulk lifetime and the surface recombination velocity. The effective lifetimes are fit to an analytical physics-based model to determine the desired parameters. Passivated and non-passivated samples are both studied and are shown to have good agreement with the theoretical model.

  17. Occupational risk and lifetime exposure

    International Nuclear Information System (INIS)

    Lapp, R.E.

    1991-01-01

    Any lowering of annual radiation limits for occupational exposure should be based on industry experience with lifetime doses and not on a worst case career exposure of 47 years. Two decades of experience show a lifetime accumulation of less than 1.5 rem for workers with measurable exposure. This is 5% of the normal lifetime exposure of Americans to natural and medical radiation. Any epidemiology of the US nuclear power workforce's two decade long exposure would have to focus on excess leukemia. Application of the Hiroshima and Nagasaki cancer mortality shows that too few leukemias would be expressed to permit a feasible epidemiology. Ionizing radiation appears to be a mild carcinogen as compared to physical and chemical agents presented in the occupational environment. A realistic factor in determining any change in occupational exposure limits for ionizing radiation should take into account the past performance of the licensee and potential health effects applicable to the workplace. Specifically, the lifetime exposure data for workers at nuclear power plants and naval shipyards should be considered. The nuclear industry and the US Navy have detailed data on the annual exposure of workers with a combined collective exposure approaching 1 million worker-rem. The lifetime dose for naval personnel and shipyard workers averages 1.1 rem J 1990. Shipyard workers have an annual dose of 0.28 rem per work-year and a mean exposure time of 4.4 years. The data apply to workers with measurable dose

  18. ''LIFETIME'': a computer program for analyzing Doppler-shift recoil-distance nuclear lifetime data

    International Nuclear Information System (INIS)

    Wells, J.C.; Fewell, M.P.; Johnson, N.R.

    1985-10-01

    The program LIFETIME is designed to extract lifetimes of nuclear levels from Doppler-shift recoil-distance experiments by performing a least-square fit to the experimental data (shifted and unshifted photopeak intensities and branching ratios). Initial populations of levels and transition rates between levels are treated as variable parameters. In terms of these parameters the population of each level as a function of time is determined by the Bateman equations, and the shifted and unshifted intensities are calculated. 19 refs., 5 figs

  19. RDM lifetime measurements in 187Tl

    International Nuclear Information System (INIS)

    Chamoli, S.K.; Joshi, P.; Kumar, A.; Govil, I.M.; Mukherjee, G.; Singh, R.P.; Muralithar, S.; Bhowmik, R.K.

    2003-01-01

    The present work is an attempt to study the shape changes in 187 Tl through a measurement of electromagnetic transition probabilities of the high spin states. The Doppler shifted recoil distance technique was used to measure the lifetimes

  20. Deposition of Y thin films by nanosecond UV pulsed laser ablation for photocathode application

    International Nuclear Information System (INIS)

    Lorusso, A.; Anni, M.; Caricato, A.P.; Gontad, F.; Perulli, A.; Taurino, A.; Perrone, A.; Chiadroni, E.

    2016-01-01

    In this work, yttrium (Y) thin films have been deposited on Si (100) substrates by the pulsed laser deposition technique. Ex-situ morphological, structural and optical characterisations of such films have been performed by scanning electron microscopy, X-ray diffractometry, atomic force microscopy and ellipsometry. Polycrystalline films with a thickness of 1.2 μm, homogenous with a root mean square roughness of about 2 nm, were obtained by optimised laser irradiation conditions. Despite the relatively high thickness, the films resulted very adherent to the substrates. The high quality of such thin films is important to the synthesis of metallic photocathodes based on Y thin film, which could be used as electron sources of high photoemission performance in radio-frequency guns. - Highlights: • Pulsed laser deposition of Yttrium thin films is investigated. • 1.2 μm thick films were deposited with very low RMS roughness. • The Y thin films were very adherent to the Si substrate • Optical characterisation showed a very high absorption coefficient for the films.

  1. Deposition of Y thin films by nanosecond UV pulsed laser ablation for photocathode application

    Energy Technology Data Exchange (ETDEWEB)

    Lorusso, A. [Università del Salento, Dipartimento di Matematica e Fisica “E. De Giorgi”, 73100 Lecce (Italy); Istituto Nazionale di Fisica Nucleare-Lecce, 73100 Lecce (Italy); Anni, M. [Università del Salento, Dipartimento di Matematica e Fisica “E. De Giorgi”, 73100 Lecce (Italy); Caricato, A.P. [Università del Salento, Dipartimento di Matematica e Fisica “E. De Giorgi”, 73100 Lecce (Italy); Istituto Nazionale di Fisica Nucleare-Lecce, 73100 Lecce (Italy); Gontad, F., E-mail: francisco.gontad@le.infn.it [Università del Salento, Dipartimento di Matematica e Fisica “E. De Giorgi”, 73100 Lecce (Italy); Istituto Nazionale di Fisica Nucleare-Lecce, 73100 Lecce (Italy); Perulli, A. [Università del Salento, Dipartimento di Matematica e Fisica “E. De Giorgi”, 73100 Lecce (Italy); Taurino, A. [National Research Council, Institute for Microelectronics & Microsystems, 73100 Lecce (Italy); Perrone, A. [Università del Salento, Dipartimento di Matematica e Fisica “E. De Giorgi”, 73100 Lecce (Italy); Istituto Nazionale di Fisica Nucleare-Lecce, 73100 Lecce (Italy); Chiadroni, E. [Laboratori Nazionali di Frascati, Istituto Nazionale di Fisica Nucleare, 00044 Frascati (Italy)

    2016-03-31

    In this work, yttrium (Y) thin films have been deposited on Si (100) substrates by the pulsed laser deposition technique. Ex-situ morphological, structural and optical characterisations of such films have been performed by scanning electron microscopy, X-ray diffractometry, atomic force microscopy and ellipsometry. Polycrystalline films with a thickness of 1.2 μm, homogenous with a root mean square roughness of about 2 nm, were obtained by optimised laser irradiation conditions. Despite the relatively high thickness, the films resulted very adherent to the substrates. The high quality of such thin films is important to the synthesis of metallic photocathodes based on Y thin film, which could be used as electron sources of high photoemission performance in radio-frequency guns. - Highlights: • Pulsed laser deposition of Yttrium thin films is investigated. • 1.2 μm thick films were deposited with very low RMS roughness. • The Y thin films were very adherent to the Si substrate • Optical characterisation showed a very high absorption coefficient for the films.

  2. Calculating excess lifetime risk in relative risk models

    International Nuclear Information System (INIS)

    Vaeth, M.; Pierce, D.A.

    1990-01-01

    When assessing the impact of radiation exposure it is common practice to present the final conclusions in terms of excess lifetime cancer risk in a population exposed to a given dose. The present investigation is mainly a methodological study focusing on some of the major issues and uncertainties involved in calculating such excess lifetime risks and related risk projection methods. The age-constant relative risk model used in the recent analyses of the cancer mortality that was observed in the follow-up of the cohort of A-bomb survivors in Hiroshima and Nagasaki is used to describe the effect of the exposure on the cancer mortality. In this type of model the excess relative risk is constant in age-at-risk, but depends on the age-at-exposure. Calculation of excess lifetime risks usually requires rather complicated life-table computations. In this paper we propose a simple approximation to the excess lifetime risk; the validity of the approximation for low levels of exposure is justified empirically as well as theoretically. This approximation provides important guidance in understanding the influence of the various factors involved in risk projections. Among the further topics considered are the influence of a latent period, the additional problems involved in calculations of site-specific excess lifetime cancer risks, the consequences of a leveling off or a plateau in the excess relative risk, and the uncertainties involved in transferring results from one population to another. The main part of this study relates to the situation with a single, instantaneous exposure, but a brief discussion is also given of the problem with a continuous exposure at a low-dose rate

  3. On random age and remaining lifetime for populations of items

    DEFF Research Database (Denmark)

    Finkelstein, M.; Vaupel, J.

    2015-01-01

    We consider items that are incepted into operation having already a random (initial) age and define the corresponding remaining lifetime. We show that these lifetimes are identically distributed when the age distribution is equal to the equilibrium distribution of the renewal theory. Then we...... develop the population studies approach to the problem and generalize the setting in terms of stationary and stable populations of items. We obtain new stochastic comparisons for the corresponding population ages and remaining lifetimes that can be useful in applications. Copyright (c) 2014 John Wiley...

  4. Lifetime measurements using the recoil distance method—achievements and perspectives

    Science.gov (United States)

    Krücken, R.

    2001-07-01

    The recoil distance method (RDM) for measuring pico-second nuclear level lifetimes and its use in nuclear structure studies is reviewed and perspectives for the future are presented. High precision measurements in the mass-130 region, studies of multi-phonon states in rare earth nuclei, the investigation of shape coexistence and the recently discovered phenomenon of "magnetic rotation" are reviewed. Prospects for lifetime measurements in exotic regions of nuclei such as the measurement of lifetimes in neutron rich nuclei populated via spontaneous and heavy-ion induced fission are discussed. Other prospects include the use of the RDM technique in conjunction with recoil separators. The relevance of these techniques for experiments with radioactive ion beams will be discussed.

  5. Lifetime measurements using the recoil distance method - achievements and perspectives

    International Nuclear Information System (INIS)

    Kruecken, R.

    2001-01-01

    The recoil distance method (RDM) for measuring pico-second nuclear level lifetimes and its use in nuclear structure studies is reviewed and perspectives for the future are presented. High precision measurements in the mass-130 region, studies of multi-phonon states in rare earth nuclei, the investigation of shape coexistence and the recently discovered phenomenon of 'magnetic rotation' are reviewed. Prospects for lifetime measurements in exotic regions of nuclei such as the measurement of lifetimes in neutron rich nuclei populated via spontaneous and heavy-ion induced fission are discussed. Other prospects include the use of the RDM technique in conjunction with recoil separators. The relevance of these techniques for experiments with radioactive ion beams will be discussed

  6. Structural studies of spinel manganite ceramics with positron annihilation lifetime spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Klym, H; Shpotyuk, O; Hadzaman, I [Institute of Materials of SRC ' Carat' , 202 Stryjska str., Lviv, 79031 (Ukraine); Ingram, A [Opole University of Technology, 75 Ozimska str., Opole, 45370 (Poland); Filipecki, J, E-mail: shpotyuk@novas.lviv.ua, E-mail: klymha@yahoo.com [Institute of Physics of Jan Dlugosz University, 13/15 Armii Krajowei, 42201, Czestochowa (Poland)

    2011-04-01

    The new transition-metal manganite Cu{sub 0.1}Ni{sub 0.8}Co{sub 0.2}Mn{sub 1.9}O{sub 4} ceramics for temperature sensors with improved functional reliability are first proposed. It is established that the amount of additional NiO phase in these ceramics extracted during sintering play a decisive role. This effect is well revealed only in ceramics having a character fine-grain microstructure, while the monolithization of ceramics caused by great amount of transferred thermal energy reveals an opposite influence. The process of monolitization from the position of evolution of grain-pore structure was studied in these ceramics using positron annihilation lifetime spectroscopy.

  7. Structural studies of spinel manganite ceramics with positron annihilation lifetime spectroscopy

    International Nuclear Information System (INIS)

    Klym, H; Shpotyuk, O; Hadzaman, I; Ingram, A; Filipecki, J

    2011-01-01

    The new transition-metal manganite Cu 0.1 Ni 0.8 Co 0.2 Mn 1.9 O 4 ceramics for temperature sensors with improved functional reliability are first proposed. It is established that the amount of additional NiO phase in these ceramics extracted during sintering play a decisive role. This effect is well revealed only in ceramics having a character fine-grain microstructure, while the monolithization of ceramics caused by great amount of transferred thermal energy reveals an opposite influence. The process of monolitization from the position of evolution of grain-pore structure was studied in these ceramics using positron annihilation lifetime spectroscopy.

  8. Positron lifetime and Moessbauer study of Fe80-xNixB20 metallic glasses

    International Nuclear Information System (INIS)

    Baluch, S.; Miglierini, M.; Groene, R.; Sitek, J.

    1989-01-01

    In order to investigate the short-range order (SRO) of iron-rich Fe 80-x Ni x B 20 (x = 10, 20, 30, 40) metallic glasses positron lifetime and Moessbauer measurements were carried out. Positron lifetimes of samples and Moessbauer hyperfine structure data of neutron-irradiated samples as functions of nickel content are shown and discussed. Results give evidence that high Ni content stabilizes the structure and can be connected with a higher degree of SRO in metallic glasses

  9. The EPDS-Lifetime: assessment of lifetime prevalence and risk factors for perinatal depression in a large cohort of depressed women

    NARCIS (Netherlands)

    Meltzer-Brody, S.; Boschloo, L.; Jones, I.; Sullivan, P.F.; Penninx, B.W.J.H.

    2013-01-01

    Perinatal depression (PND) is a common complication of pregnancy and postpartum associated with significant morbidity. We had three goals: (1) to explore the performance of a new lifetime version of the Edinburgh Postnatal Depression Scale (EPDS-Lifetime) to assess lifetime prevalence of PND; (2) to

  10. The EPDS-Lifetime : assessment of lifetime prevalence and risk factors for perinatal depression in a large cohort of depressed women

    NARCIS (Netherlands)

    Meltzer-Brody, Samantha; Boschloo, Lynn; Jones, Ian; Sullivan, Patrick F.; Penninx, Brenda W.

    2013-01-01

    Perinatal depression (PND) is a common complication of pregnancy and postpartum associated with significant morbidity. We had three goals: (1) to explore the performance of a new lifetime version of the Edinburgh Postnatal Depression Scale (EPDS-Lifetime) to assess lifetime prevalence of PND; (2) to

  11. A study of relationship between optical basicity and positron lifetime in oxides

    International Nuclear Information System (INIS)

    Xu Zongliang; Liu Shangjin

    1994-01-01

    Positron annihilation lifetime spectra have been measured for the samples of Na 2 O-B 2 O 3 melt, B 2 O 3 , SiO 2 , V 2 O 5 and Na 2 O-TiO 2 melt during sharp cooling with a cooling rate > 180 K · s -1 . The results show a quite well linear relation between optical basicity Λ and the first component τ 1 of the lifetime spectra for non-transition metal oxides: Λ = 0.173 (1/τ 1 )+0.060. With this relationship and τ 1 measured by PA the Λ values for ZnO, TiO 2 and V 2 O 5 are obtained to be 1.00, 0.63 and 0.75 respectively, approaching the literature values

  12. Lifetime of B hadrons from CDF

    International Nuclear Information System (INIS)

    Miao, Ting.

    1996-08-01

    A review of the lifetimes of B hadrons measured by the CDF collaboration at Fermilab is presented. The data corresponds to 110 pb -1 of p anti p collisions at √s = 1.8 TeV. The inclusive B hadron lifetime is measured using a high statistics sample of B → J/ΨΧ decays. Species specific lifetimes of the B + , B 0 , B 0 s , and Λ 0 b are determined using both fully reconstructed decays and partially reconstructed decays consisting of a lepton associated with a charm hadron

  13. Maintenance engineering of lifetime management programs

    International Nuclear Information System (INIS)

    Hervia Ruperez, F.

    1997-01-01

    The complexity of nuclear power plants obliges to stablish the adecuated management of its lifetime. This article describes the methodologies and the improvement the evaluation of lifetime programs and specially in Garona and Vandellos II Nuclear Power Plants. (Author)

  14. Single photon counting fluorescence lifetime detection of pericellular oxygen concentrations.

    Science.gov (United States)

    Hosny, Neveen A; Lee, David A; Knight, Martin M

    2012-01-01

    Fluorescence lifetime imaging microscopy offers a non-invasive method for quantifying local oxygen concentrations. However, existing methods are either invasive, require custom-made systems, or show limited spatial resolution. Therefore, these methods are unsuitable for investigation of pericellular oxygen concentrations. This study describes an adaptation of commercially available equipment which has been optimized for quantitative extracellular oxygen detection with high lifetime accuracy and spatial resolution while avoiding systematic photon pile-up. The oxygen sensitive fluorescent dye, tris(2,2'-bipyridyl)ruthenium(II) chloride hexahydrate [Ru(bipy)(3)](2+), was excited using a two-photon excitation laser. Lifetime was measured using a Becker & Hickl time-correlated single photon counting, which will be referred to as a TCSPC card. [Ru(bipy)(3)](2+) characterization studies quantified the influences of temperature, pH, cellular culture media and oxygen on the fluorescence lifetime measurements. This provided a precisely calibrated and accurate system for quantification of pericellular oxygen concentration based on measured lifetimes. Using this technique, quantification of oxygen concentrations around isolated viable chondrocytes, seeded in three-dimensional agarose gel, revealed a subpopulation of cells that exhibited significant spatial oxygen gradients such that oxygen concentration reduced with increasing proximity to the cell. This technique provides a powerful tool for quantifying spatial oxygen gradients within three-dimensional cellular models.

  15. Temperature dependence of positron lifetime in ordered porous silica (SBA-3)

    International Nuclear Information System (INIS)

    Kunishige, S.; Koshimizu, M.; Asai, K.

    2009-01-01

    The temperature dependence of positron lifetime in uniform mesopores was analyzed. We used SBA-3 as the sample material, which possesses an ordered porous structure with uniform cylindrical mesopores. The positron lifetime corresponding to the annihilation in the mesopores increased gradually with a decrease in temperature down to 100 K, and its relative intensity also increased concomitantly. This result was attributed to the lower probability of the escape of the ortho-positronium (o-Ps) from the mesopores into the intergrain space at lower temperatures. An anomalous and sudden increase in the lifetime was observed at around 100 K; this result was in agreement with an increase in the positron lifetime reported in a previous study. It was revealed that the increase in the lifetime is very steep in cases of uniform mesopores, suggesting that the temperature dependence is influenced by the pore size.

  16. Observation of rotating nuclear molecules and determination of their lifetimes

    Energy Technology Data Exchange (ETDEWEB)

    Comas, V.; Heinz, S.; Ackermann, D.; Heredia, J.; Hessberger, F.P.; Khuyagbaatar, J.; Kindler, B.; Lommel, B.; Mann, R. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Hofmann, S. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Goethe-Universitaet Frankfurt, Institut fuer Physik, Frankfurt (Germany)

    2012-12-15

    Long-living rotating nuclear molecules (or ''dinuclear systems'') have been observed at the velocity filter SHIP at GSI in reactions of {sup 64}Ni + {sup 207}Pb at Coulomb barrier energies. The rotation was directly revealed by the velocity spectra of deep inelastic target-like transfer products which are formed during the lifetime of the nuclear molecule and emitted after its breakup. The corresponding rotation angles were about 180 degree pointing to long nuclear interaction times or lifetimes of the system, respectively. We deduced the lifetimes from the lines in the velocity spectra originating from two different rotation angles. Further, the unambiguous correlation of a certain transfer product with its individual velocity spectrum allowed us to study the lifetimes as a function of the number of transferred protons. (orig.)

  17. Temporal laser pulse shaping for RF photocathode guns: the cheap and easy way using UV birefringent crystals

    International Nuclear Information System (INIS)

    Power, J.G.; Jing, C.

    2009-01-01

    We report experimental investigations into a new technique for achieving temporal laser pulse shaping for RF photocathode gun applications using inexpensive UV birefringent crystals. Exploiting the group velocity mismatch between the two different polarizations of a birefringent crystal, a stack of UV pulses can be assembled into the desired temporal pulse shape. The scheme is capable of generating a variety of temporal pulse shapes including: (i) flat-top pulses with fast rise-time and variable pulse duration. (ii) microbunch trains, and (iii) ramped pulse generation. We will consider two applications for beam generation at the Argonne Wakefield Accelerator (AWA) including a flat-top laser pulse for low emittance production and matched bunch length for enhanced transformer ratio production. Streak camera measurements of the temporal profiles generated with a 2-crystal set and a 4-crystal set are presented.

  18. Electrochemically deposited Cu{sub 2}O cubic particles on boron doped diamond substrate as efficient photocathode for solar hydrogen generation

    Energy Technology Data Exchange (ETDEWEB)

    Mavrokefalos, Christos K. [Department of Chemistry, Chemistry Research Laboratory, University of Oxford, Mansfield Road, Oxford, OX1 3TA, England (United Kingdom); Hasan, Maksudul, E-mail: maksudul.hasan@chem.ox.ac.uk [Department of Chemistry, Chemistry Research Laboratory, University of Oxford, Mansfield Road, Oxford, OX1 3TA, England (United Kingdom); Tyndall National Institute, University College Cork, Lee Maltings, Cork (Ireland); Rohan, James F. [Tyndall National Institute, University College Cork, Lee Maltings, Cork (Ireland); Compton, Richard G. [Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford, OX1 3QZ, England (United Kingdom); Foord, John S., E-mail: john.foord@chem.ox.ac.uk [Department of Chemistry, Chemistry Research Laboratory, University of Oxford, Mansfield Road, Oxford, OX1 3TA, England (United Kingdom)

    2017-06-30

    Highlights: • Fabrication of low-cost photocathode by electrochemical method is described. • Boron-doped diamond is presented as catalyst support. • NiO nanoparticles on Cu{sub 2}O surface enhances photocurrent and electrode stability. • Synergy of metallic interaction between Cu and Ni leads to high efficiency. - Abstract: Herein, we report a novel photocathode for the water splitting reaction. The electrochemical deposition of Cu{sub 2}O particles on boron doped diamond (BDD) electrodes and the subsequent decoration with NiO nanoparticles by a dip coating method to act as co-catalyst for hydrogen evolution reaction is described. The morphology analysis by scanning electron microscope (SEM) revealed that Cu{sub 2}O particles are cubic and decorated sporadically with NiO nanoparticles. X-ray photoelectron spectroscopy (XPS) confirmed the electronic interaction at the interface between Cu{sub 2}O and NiO through a binding energy shift of the main Cu 2p peak. The photoelectrochemical (PEC) performance of NiO-Cu{sub 2}O/BDD showed a much higher current density (−0.33 mA/cm{sup 2}) and photoconversion efficiency (0.28%) compared to the unmodified Cu{sub 2}O/BDD electrode, which are only −0.12 mA/cm{sup 2} and 0.06%, respectively. The enhancement in PEC performance is attributable to the synergy of NiO as an electron conduction mediator leading to the enhanced charge separation and transfer to the reaction interface for hydrogen evolution as evidenced by electrochemical impedance spectroscopy (EIS) and charge carrier density calculation. Stability tests showed that the NiO nanoparticles loading content on Cu{sub 2}O surface is a crucial parameter in this regard.

  19. Cation vacancies in ferroelectric PbTiO3 and Pb(Zr,Ti)O3 : A positron annihilation lifetime spectroscopy study

    Science.gov (United States)

    Keeble, D. J.; Singh, S.; Mackie, R. A.; Morozov, M.; McGuire, S.; Damjanovic, D.

    2007-10-01

    Positron annihilation lifetime spectroscopy measurements identify A - and B -site cation vacancies in ferroelectric perovskite oxides (ABO3) . Crystal PbTiO3 and ceramic lead zirconium titanate (PZT) were studied and gave consistent values for the lifetime resulting from positron localization at lead vacancies VPb . Positron trapping to B -site vacancies was inferred in PZT. Temperature dependent studies showed that the defect specific trapping rate was higher for VB compared to VPb , consistent with the larger negative charge. Doping PZT with Fe increased the fraction positron trapping to VB compared to VPb -type defects.

  20. Study on defect properties of nanocrystalline TiO2 during phase transition by positron annihilation lifetime

    Science.gov (United States)

    Zheng, F.; Liu, Y.; Liu, Z.; Dai, Y.-Q.; Fang, P.-F.; Wang, S.-J.

    2012-08-01

    The defect properties of nanocrystalline TiO2 were investigated by positron annihilation lifetime spectroscopy (PALS) and X-ray diffraction (XRD) as a function of annealed temperature that ranged from 300 to 850 °C. Below 500 °C, the measured positron lifetimes of τ1 (200-206 ps) and τ2 (378-402 ps) revealed the existence of mono-vacancy and vacancy-clusters at grain surface and in the micro-void of intergranular region. Between 500 and 750 °C, the phase transition from anatase to rutile was probed by the variations of positron lifetime and XRD pattern. With the increasing temperature from 500 to 850 °C, the positron lifetime τ1, τ2 and its intensity I2 sharply decreased from 200 ps, 378 ps, and 60% to 135 ps, 274 ps, and 33%, respectively. The results clearly indicate that the mono-vacancy or vacancy-clusters at grain surface and micro-voids between the grains were annealed out during the phase transition.

  1. Luminosity lifetime in the Tevatron

    International Nuclear Information System (INIS)

    Jackson, G.; Finley, D.; Johnson, R.P.; Kerns, Q.; McCarthy, J.; Siemann, R.; Zhang, P.

    1988-01-01

    Since the inauguration of colliding proton-antiproton operations in 1987, the Tevatron has exhibited luminosity lifetimes shorter than expected. During a typical colliding beam storage period, called a store, luminosity is calculated periodically by measuring the charge and emittances of each bunch. The growth of the transverse bunch emittances is the dominant cause of luminosity deterioration. Throughout, this period, the position spectrum of the bunches exhibited betatron signals larger than expected from Schottky noise. A model assuming externally driven betatron oscillations explains both the betatron signals and the emittance growth. A program is underway to improve the Tevatron luminosity lifetime. The abort kickers have been identified as sources of emittance growth, and some quadrupole power supplies are further candidates. Because the horizontal dispersion through the RF cavities is nonzero, RF phase noise has been investigated. Noise in the main dipole regulation circuit has also been studied. 13 refs., 4 figs

  2. Positron annihilation lifetime study of positive temperature coefficient BaTiO3 samples

    International Nuclear Information System (INIS)

    Ling Chen; Mingkang Teng; Guanghou Wang; Xiaoyun Li; Tianchang Lu

    1989-01-01

    In order to investigate the doped vacancies in BaTiO 3 samples as well as their influence on the positive temperature coefficient (PTC) the positron annihilation lifetime spectroscopy was applied. Two groups of BaTiO 3 samples with BaO excess were prepared by doping different concentrations of La 2 O 3 and Nb 2 O 5 , respectively in the range from 0.1 to 3 at%. A third group of samples of two Sb-doped PTC BaTiO 3 semiconductors with excess BaO or TiO 2 were studied by the aid of positron technique before and after being reduced. It is shown that the positron lifetime parameters are sensitive to changes in the vacancy concentration in BaTiO 3 ceramics near the 0.1 mol% region. But they are almost unchanged during reduction processing; the resistivity of samples changed by one to two orders of magnitude through the reduction. It can be concluded that the PTC effect is due to oxygen on the grain boundary rather than vacancies, and that the Heywang-Jonker model is more reasonable

  3. Two-dimensional fluorescence lifetime correlation spectroscopy. 2. Application.

    Science.gov (United States)

    Ishii, Kunihiko; Tahara, Tahei

    2013-10-03

    In the preceding article, we introduced the theoretical framework of two-dimensional fluorescence lifetime correlation spectroscopy (2D FLCS). In this article, we report the experimental implementation of 2D FLCS. In this method, two-dimensional emission-delay correlation maps are constructed from the photon data obtained with the time-correlated single photon counting (TCSPC), and then they are converted to 2D lifetime correlation maps by the inverse Laplace transform. We develop a numerical method to realize reliable transformation, employing the maximum entropy method (MEM). We apply the developed actual 2D FLCS to two real systems, a dye mixture and a DNA hairpin. For the dye mixture, we show that 2D FLCS is experimentally feasible and that it can identify different species in an inhomogeneous sample without any prior knowledge. The application to the DNA hairpin demonstrates that 2D FLCS can disclose microsecond spontaneous dynamics of biological molecules in a visually comprehensible manner, through identifying species as unique lifetime distributions. A FRET pair is attached to the both ends of the DNA hairpin, and the different structures of the DNA hairpin are distinguished as different fluorescence lifetimes in 2D FLCS. By constructing the 2D correlation maps of the fluorescence lifetime of the FRET donor, the equilibrium dynamics between the open and the closed forms of the DNA hairpin is clearly observed as the appearance of the cross peaks between the corresponding fluorescence lifetimes. This equilibrium dynamics of the DNA hairpin is clearly separated from the acceptor-missing DNA that appears as an isolated diagonal peak in the 2D maps. The present study clearly shows that newly developed 2D FLCS can disclose spontaneous structural dynamics of biological molecules with microsecond time resolution.

  4. Deep level transient spectroscopy and minority carrier lifetime study on Ga-doped continuous Czochralski silicon

    Science.gov (United States)

    Yoon, Yohan; Yan, Yixin; Ostrom, Nels P.; Kim, Jinwoo; Rozgonyi, George

    2012-11-01

    Continuous-Czochralski (c-Cz) crystal growth has been suggested as a viable technique for the fabrication of photovoltaic Si wafers due to its low resistivity variation of any dopant, independent of segregation, compared to conventional Cz. In order to eliminate light induced degradation due to boron-oxygen traps in conventional p-type silicon wafers, gallium doped wafers have been grown by c-Cz method and investigated using four point probe, deep level transient spectroscopy (DLTS), and microwave-photoconductance decay. Iron-gallium related electrically active defects were identified using DLTS as the main lifetime killers responsible for reduced non-uniform lifetimes in radial and axial positions of the c-Cz silicon ingot. A direct correlation between minority carrier lifetime and the concentration of electrically active Fe-Ga pairs was established.

  5. Free volume changes in mechanically milled PS and PC studied by positron annihilation lifetime spectroscopy (PALS)

    NARCIS (Netherlands)

    Günther-Schade, K.; Castricum, H.L.; Ziegler, H.J.; Bakker, H.; Faupel, F.

    2004-01-01

    The effect of mechanical milling on free volume was studied by means of positron annihilation lifetime spectroscopy (PALS) in polystyrene (PS) as a typical brittle polymer and in polycarbonate (PC) as a tough representative. Long-time milling increases the free volume, while a decrease is observed

  6. Measuring and sorting cell populations expressing isospectral fluorescent proteins with different fluorescence lifetimes.

    Directory of Open Access Journals (Sweden)

    Bryan Sands

    Full Text Available Study of signal transduction in live cells benefits from the ability to visualize and quantify light emitted by fluorescent proteins (XFPs fused to different signaling proteins. However, because cell signaling proteins are often present in small numbers, and because the XFPs themselves are poor fluorophores, the amount of emitted light, and the observable signal in these studies, is often small. An XFP's fluorescence lifetime contains additional information about the immediate environment of the fluorophore that can augment the information from its weak light signal. Here, we constructed and expressed in Saccharomyces cerevisiae variants of Teal Fluorescent Protein (TFP and Citrine that were isospectral but had shorter fluorescence lifetimes, ∼ 1.5 ns vs ∼ 3 ns. We modified microscopic and flow cytometric instruments to measure fluorescence lifetimes in live cells. We developed digital hardware and a measure of lifetime called a "pseudophasor" that we could compute quickly enough to permit sorting by lifetime in flow. We used these abilities to sort mixtures of cells expressing TFP and the short-lifetime TFP variant into subpopulations that were respectively 97% and 94% pure. This work demonstrates the feasibility of using information about fluorescence lifetime to help quantify cell signaling in living cells at the high throughput provided by flow cytometry. Moreover, it demonstrates the feasibility of isolating and recovering subpopulations of cells with different XFP lifetimes for subsequent experimentation.

  7. Positron lifetime studies of Bi2Sr2CaCu2Oy-xFx superconductors

    International Nuclear Information System (INIS)

    Shi Zhiqiang; Chao Xixu; Wu Lingyun

    1994-01-01

    The positron lifetime was measured as a function of doped F content for Bi 2 Sr 2 CaCu 2 O y-x F x superconductor. Combined with the measurement of critical temperature T c , the sites where F substituted for O and the change of electronic structures caused by local substitution of F in the samples were studied

  8. Cosmological constraints on the neutron lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Salvati, L.; Pagano, L.; Melchiorri, A. [Physics Department, Università di Roma ' ' La Sapienza' ' , Piazzale Aldo Moro 2, 00185, Rome (Italy); Consiglio, R., E-mail: laura.salvati@roma1.infn.it, E-mail: luca.pagano@roma1.infn.it, E-mail: rconsiglio@na.infn.it, E-mail: alessandro.melchiorri@roma1.infn.it [Physics Department, Università di Napoli ' ' Federico II' ' , Complesso Universitario Monte S. Angelo, Via Cintia, I-80126 Napoli (Italy)

    2016-03-01

    We derive new constraints on the neutron lifetime based on the recent Planck 2015 observations of temperature and polarization anisotropies of the CMB. Under the assumption of standard Big Bang Nucleosynthesis, we show that Planck data constrains the neutron lifetime to τ{sub n} = (907±69) [s] at 68% c.l.. Moreover, by including the direct measurements of primordial Helium abundance of Aver et al. (2015) and Izotov et al. (2014), we show that cosmological data provide the stringent constraints τ{sub n} = (875±19) [s] and τ{sub n} = (921±11) [s] respectively. The latter appears to be in tension with neutron lifetime value quoted by the Particle Data Group (τ{sub n} = (880.3±1.1) [s]). Future CMB surveys as COrE+, in combination with a weak lensing survey as EUCLID, could constrain the neutron lifetime up to a ∼ 6 [s] precision.

  9. Lifetime studies of self-activated photoluminescence in heavily silicon-doped GaAs

    Science.gov (United States)

    Sauncy, T.; Palsule, C. P.; Holtz, M.; Gangopadhyay, S.; Massie, S.

    1996-01-01

    We report results of a detailed temperature dependence study of photoluminescence lifetime and continuous emission properties in silicon-doped GaAs. The primary focus is on a defect-related emission at 1.269 eV (T=20 K). GaAs crystals were grown using molecular-beam epitaxy with most of the experiments conducted on a sample having a carrier concentration of 4.9×1018 cm-3. The intensity is seen to decrease above 100 K, with no corresponding decrease in the measured lifetime of 9.63+/-0.25 ns. The intensity decrease implies an activation energy of 19+/-2 meV, which is approximately one order of magnitude smaller than what was previously obtained for similar defects in Czochralski-grown GaAs with other dopants. We interpret our results in terms of a configuration coordinate model and obtain a more complete picture of the energy-level structure. The experiments indicate that the upper level in the recombination process is about 20 meV below the conduction-band continuum, with the lower state approximately 300 meV above the valence band. Our results are consistent with the identification of the corresponding defect complex microstructure as being a silicon-at-gallium substitution, weakly interacting with a gallium vacancy second-nearest neighbor, known as the Si-Y defect complex.

  10. Reliability and Validity of an Internet-based Questionnaire Measuring Lifetime Physical Activity

    OpenAIRE

    De Vera, Mary A.; Ratzlaff, Charles; Doerfling, Paul; Kopec, Jacek

    2010-01-01

    Lifetime exposure to physical activity is an important construct for evaluating associations between physical activity and disease outcomes, given the long induction periods in many chronic diseases. The authors' objective in this study was to evaluate the measurement properties of the Lifetime Physical Activity Questionnaire (L-PAQ), a novel Internet-based, self-administered instrument measuring lifetime physical activity, among Canadian men and women in 2005–2006. Reliability was examined u...

  11. Lifetime of chaotic attractors in a multidimensional laser system

    International Nuclear Information System (INIS)

    Pando L, C.L.; Cerdeira, H.A.

    1995-01-01

    We study the lifetimes of chaotic attractors at crises in a multidimensional laser system. This system describes the CO 2 laser with modulated losses and is known as the four-level model. The critical exponents which are related to the lifetimes of the attractors are estimated in terms of the corresponding eigenvalues and the measured characteristic lifetime in the model. The critical exponents in this model and those of its center manifold version are in good agreement. We conjecture that generically in the four-level model the critical exponents are close to 1/2 at crises. In addition, we compare predictions of a simpler and popular model known as the two-level model with those of the above mentioned models. (author). 21 refs, 2 figs, 3 tabs

  12. On the potential of positron lifetime spectroscopy for the study of early stages of zeolites formation from their amorphous precursors

    International Nuclear Information System (INIS)

    Bosnar, S.; Kosanovic, C.; Subotic, B.; Bosnar, D.; Kajcsos, Zs.; Liszkay, L.; Lohonyai, L.; Molnar, B.; Lazar, K.

    2007-01-01

    The applicability of positron lifetime (LT) spectroscopy to the study of progress of formation of Secondary Building Units (SBU) in gels yielding in FAU and LTA type zeolites was investigated. Samples were prepared from aluminosilicate gels with various degrees of local structural order. LT measurements were performed at room temperature in air and in vacuum. Coexistence of annihilation modi with long lifetime components was shown; a correlation with precursors of nucleation and type of exchanged ions was also indicated

  13. Lifetime measurement of ATF damping ring

    International Nuclear Information System (INIS)

    Okugi, T.; Hayano, H.; Kubo, K.; Naito, T.; Terunuma, N.; Urakawa, J.; Zimmermann, F.

    1998-06-01

    The purpose of the ATF damping ring is the development of technologies for producing a low emittance beam required in future linear colliders such as JLC. The lifetime of the damping ring is very short (typically a few minutes). It is limited by elastic beam-gas scattering along with a small dynamic aperture, and by single intra-beam scattering (Touschek effect). The Touschek lifetime strongly depends upon the charge density of the beam, especially, the size of the vertical emittance. In this paper, the authors report the results of beam lifetime measurements in the ATF damping ring and the estimation of the vertical emittance from these measurements

  14. Lifetime measurements of hadrons containing heavy quarks

    International Nuclear Information System (INIS)

    Forden, G.E.

    1985-01-01

    Recent lifetime measurements of heavy particles at PETRA and PEP are reviewed. A comparison of the methods used is given. The world averages for the lifetimes of the D 0 and D +- mesons are found to be (tau/dub D/ 0 ) - 3.97 +/- 0.3 x 10 -13 sec and (tau/dub D +-/) = 8.6 +/- 0.7 x 10 -13 sec. This difference in lifetimes is discussed in light of recent information about exclusive decays. The world average for the lifetime of bottom hadrons is determined to be (tau/sub b/) = 11.0 +/- 1.5 x 10 -13 sec and new estimates for the b quark mixing elements, absolute value V/sub bu/ and absolute value V/sub bc/, are given

  15. Maximizing System Lifetime by Battery Scheduling

    NARCIS (Netherlands)

    Jongerden, M.R.; Haverkort, Boudewijn R.H.M.; Bohnenkamp, H.C.; Katoen, Joost P.

    2009-01-01

    The use of mobile devices is limited by the battery lifetime. Some devices have the option to connect an extra battery, or to use smart battery-packs with multiple cells to extend the lifetime. In these cases, scheduling the batteries over the load to exploit recovery properties usually extends the

  16. Positron lifetime measurements on electron irradiated amorphous alloys

    International Nuclear Information System (INIS)

    Moser, P.; Hautojaervi, P.; Chamberod, A.; Yli-Kauppila, J.; Van Zurk, R.

    1981-08-01

    Great advance in understanding the nature of point defects in crystalline metals has been achieved by employing positron annihilation technique. Positrons detect vacancy-type defects and the lifetime value of trapped positrons gives information on the size of submicroscopic vacancy aglomerates and microvoids. In this paper it is shown that low-temperature electron irradiations can result in a considerable increase in the positron lifetimes in various amorphous alloys because of the formation of vacancy-like defects which, in addition of the pre-existing holes, are able to trap positrons. Studied amorphous alloys were Fe 80 B 20 , Pd 80 Si 20 , Cu 50 Ti 50 , and Fe 40 Ni 40 P 14 B 6 . Electron irradiations were performed with 3 MeV electrons at 20 K to doses around 10 19 e - /cm 2 . After annealing positron lifetime spectra were measured at 77 K

  17. Positron lifetime studies of the hcp to fcc transformation induced by mechanical attrition of elemental titanium

    International Nuclear Information System (INIS)

    Manna, I.; Chattopadhyay, P.P.; Nandi, P.; Nambissan, P.M.G.

    2004-01-01

    Nanocrystallisation by planetary ball-milling of high purity elemental titanium (Ti) revealed a polymorphic transformation from its normal hexagonal close packed (hcp) structure to a face-centered cubic (fcc) phase. Positron lifetime measurements were carried out on samples collected after different hours of milling to characterize the defect structures at grain surfaces. With increasing hours of milling, the nanocrystalline grain size decreased and the positron lifetimes--one related to the annihilation at the grain surfaces and the other to that at the intergranular open volume domains--increased significantly due to the increased free volume at the trapping vacancy sites. However, between 5 to 10 hours of milling, the two lifetimes decreased before resuming increasing once again. This marked deviation from an otherwise expected continuous increase of positron lifetime coincided with structural rearrangement within the system bringing in an enhancement in the density of electrons. The repacking of atoms along the [0001] crystallographic direction could be a possibility for this observation. Positron radiation effects on the migration and agglomeration of nanoparticles are also discussed

  18. RDM-lifetime study in 125La

    International Nuclear Information System (INIS)

    Starosta, K.; Droste, C.; Morek, T.

    1995-01-01

    Recoil Distance Method (RDM) lifetime measurements have been carried out at Stony Brook for the 125 La nucleus to examine the collective structure of the decoupled band based on the unique parity πh 11/2 [550]1/2 orbital in comparison to that of the 124 Ba core. The 94 Mo( 35 Cl,2p2n) reaction was used at a beam energy of 155 MeV in conjunction with the Notre Dame plunger. Five BGO-suppressed Ge detectors were employed at ±30 degrees, 90 degrees, 123 degrees, and 150 degrees relative to the beam direction to measure the stopped and shifted γ-ray peaks as a function of target-stopper distance. A 14-element BGO multiplicity filter surrounding the target was recorded along with the γ-ray singles events to allow background reduction from Coulex and radioactivity. Preliminary meanlife slopes observed at 30 degrees for the 15/2 - , 19/2 - , and 23/2 - band members were 140(20), 9(3), and 2(2) ps, respectively. Multiple-level fits and time-dependent alignment corrections have not been made. The resulting B(E2) values will be compared with theoretical calculations

  19. Lifetime of a black hole

    International Nuclear Information System (INIS)

    Carlitz, R.D.; Willey, R.S.

    1987-01-01

    We study the constraints placed by quantum mechanics upon the lifetime of a black hole. In the context of a moving-mirror analog model for the Hawking radiation process, we conclude that the period of Hawking radiation must be followed by a much longer period during which the remnant mass (of order m/sub P/) may be radiated away. We are able to place a lower bound on the time required for this radiation process, which translates into a lower bound for the lifetime of the black hole. Particles which are emitted during the decay of the remnant, like the particles which comprise the Hawking flux, may be uncorrelated with each other. But each particle emitted from the decaying remnant is correlated with one particle emitted as Hawking radiation. The state which results after the remnant has evaporated is one which locally appears to be thermal, but which on a much larger scale is marked by extensive correlations

  20. Improving, characterizing and predicting the lifetime of organic photovoltaics

    DEFF Research Database (Denmark)

    Gevorgyan, Suren A.; Heckler, Ilona Maria; Bundgaard, Eva

    2017-01-01

    This review summarizes the recent progress in the stability and lifetime of organic photovoltaics (OPVs). In particular, recently proposed solutions to failure mechanisms in different layers of the device stack are discussed comprising both structural and chemical modifications. Upscaling...... characterization reported recently. Lifetime testing and determination is another challenge in the field of organic solar cells and the final sections of this review discuss the testing protocols as well as the generic marker for device lifetime and the methodology for comparing all the lifetime landmarks in one...... common diagram. These tools were used to determine the baselines for OPV lifetime tested under different ageing conditions. Finally, the current status of lifetime for organic solar cells is presented and predictions are made for progress in the near future....

  1. Refractive index sensing using Fluorescence Lifetime Imaging (FLIM)

    International Nuclear Information System (INIS)

    Jones, Carolyn; Suhling, Klaus

    2006-01-01

    The fluorescence lifetime is a function of the refractive index of the fluorophore's environment, for example in the case of the biologically important green fluorescent protein (GFP). In order to address the question whether this effect can be exploited to image the local environment of specific proteins in cell biology, we need to determine the distance over which the fluorophore's lifetime is sensitive to the refractive index. To this end, we employ Fluorescence Lifetime Imaging (FLIM) of fluorescein in NaOH buffer at an interface. This approach allows us to map the fluorescence lifetime as a function of distance from a buffer/air and buffer/oil interface. Preliminary data show that the fluorescence lifetime of fluorescein increases near a buffer/air interface and decreases near a buffer/oil interface. The range over which this fluorescence lifetime change occurs is found to be of the order several μm which is consistent with a theoretical model based on the full width at half maximum of the emission spectrum proposed by Toptygin

  2. Organic scintillators with long luminescent lifetimes for radiotherapy dosimetry

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Lindvold, Lars René; Andersen, Claus Erik

    2011-01-01

    of experiments performed using two organic scintillators, one commercially available and one custom made. The luminescent lifetimes of the scintillators have been measured using i) optical excitation by pulsed UV light, and ii) irradiative excitation using high-energy X-rays from a linac. A luminescent lifetime...... component on the order of 20 μs was estimated for the custom-made organic scintillator, while the commercial scintillator exhibited a fast component of approximately 5 ns lifetime (7 ns as stated by the manufacturer) and an approximate 10 μs lifetime slow component. Although these lifetimes are not long...

  3. Measurement of the $\\tau$ lepton lifetime

    CERN Document Server

    Buskulic, Damir; De Bonis, I; Décamp, D; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Minard, M N; Odier, P; Pietrzyk, B; Ariztizabal, F; Chmeissani, M; Crespo, J M; Efthymiopoulos, I; Fernández, E; Fernández-Bosman, M; Gaitan, V; Garrido, L; Martínez, M; Orteu, S; Pacheco, A; Padilla, C; Palla, Fabrizio; Pascual, A; Perlas, J A; Sánchez, F; Teubert, F; Colaleo, A; Creanza, D; De Palma, M; Farilla, A; Gelao, G; Girone, M; Iaselli, Giuseppe; Maggi, G; Maggi, M; Marinelli, N; Natali, S; Nuzzo, S; Ranieri, A; Raso, G; Romano, F; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Bonvicini, G; Cattaneo, M; Comas, P; Coyle, P; Drevermann, H; Engelhardt, A; Forty, Roger W; Frank, M; Hagelberg, R; Harvey, J; Jacobsen, R; Janot, P; Jost, B; Kneringer, E; Knobloch, J; Lehraus, Ivan; Markou, C; Martin, E B; Mato, P; Minten, Adolf G; Miquel, R; Oest, T; Palazzi, P; Pater, J R; Pusztaszeri, J F; Ranjard, F; Rensing, P E; Rolandi, Luigi; Schlatter, W D; Schmelling, M; Schneider, O; Tejessy, W; Tomalin, I R; Venturi, A; Wachsmuth, H W; Wiedenmann, W; Wildish, T; Witzeling, W; Wotschack, J; Ajaltouni, Ziad J; Bardadin-Otwinowska, Maria; Barrès, A; Boyer, C; Falvard, A; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Pallin, D; Perret, P; Podlyski, F; Proriol, J; Rossignol, J M; Saadi, F; Fearnley, Tom; Hansen, J B; Hansen, J D; Hansen, J R; Hansen, P H; Nilsson, B S; Kyriakis, A; Simopoulou, Errietta; Siotis, I; Vayaki, Anna; Zachariadou, K; Blondel, A; Bonneaud, G R; Brient, J C; Bourdon, P; Passalacqua, L; Rougé, A; Rumpf, M; Tanaka, R; Valassi, Andrea; Verderi, M; Videau, H L; Candlin, D J; Parsons, M I; Focardi, E; Parrini, G; Corden, M; Delfino, M C; Georgiopoulos, C H; Jaffe, D E; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Pepé-Altarelli, M; Dorris, S J; Halley, A W; ten Have, I; Knowles, I G; Lynch, J G; Morton, W T; O'Shea, V; Raine, C; Reeves, P; Scarr, J M; Smith, K; Smith, M G; Thompson, A S; Thomson, F; Thorn, S; Turnbull, R M; Becker, U; Braun, O; Geweniger, C; Graefe, G; Hanke, P; Hepp, V; Kluge, E E; Putzer, A; Rensch, B; Schmidt, M; Sommer, J; Stenzel, H; Tittel, K; Werner, S; Wunsch, M; Beuselinck, R; Binnie, David M; Cameron, W; Colling, D J; Dornan, Peter J; Konstantinidis, N P; Moneta, L; Moutoussi, A; Nash, J; San Martin, G; Sedgbeer, J K; Stacey, A M; Dissertori, G; Girtler, P; Kuhn, D; Rudolph, G; Bowdery, C K; Brodbeck, T J; Colrain, P; Crawford, G; Finch, A J; Foster, F; Hughes, G; Sloan, Terence; Whelan, E P; Williams, M I; Galla, A; Greene, A M; Kleinknecht, K; Quast, G; Raab, J; Renk, B; Sander, H G; Wanke, R; Van Gemmeren, P; Zeitnitz, C; Aubert, Jean-Jacques; Bencheikh, A M; Benchouk, C; Bonissent, A; Bujosa, G; Calvet, D; Carr, J; Diaconu, C A; Etienne, F; Thulasidas, M; Nicod, D; Payre, P; Rousseau, D; Talby, M; Abt, I; Assmann, R W; Bauer, C; Blum, Walter; Brown, D; Dietl, H; Dydak, Friedrich; Ganis, G; Gotzhein, C; Jakobs, K; Kroha, H; Lütjens, G; Lutz, Gerhard; Männer, W; Moser, H G; Richter, R H; Rosado-Schlosser, A; Schael, S; Settles, Ronald; Seywerd, H C J; Saint-Denis, R; Wolf, G; Alemany, R; Boucrot, J; Callot, O; Cordier, A; Courault, F; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Jacquet, M; Kim, D W; Le Diberder, F R; Lefrançois, J; Lutz, A M; Musolino, G; Nikolic, I A; Park, H J; Park, I C; Schune, M H; Simion, S; Veillet, J J; Videau, I; Abbaneo, D; Azzurri, P; Bagliesi, G; Batignani, G; Bettarini, S; Bozzi, C; Calderini, G; Carpinelli, M; Ciocci, M A; Ciulli, V; Dell'Orso, R; Fantechi, R; Ferrante, I; Fidecaro, F; Foà, L; Forti, F; Giassi, A; Giorgi, M A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Rizzo, G; Sanguinetti, G; Sciabà, A; Spagnolo, P; Steinberger, Jack; Tenchini, Roberto; Tonelli, G; Triggiani, G; Vannini, C; Verdini, P G; Walsh, J; Betteridge, A P; Blair, G A; Bryant, L M; Cerutti, F; Gao, Y; Green, M G; Johnson, D L; Medcalf, T; Mir, L M; Perrodo, P; Strong, J A; Bertin, V; Botterill, David R; Clifft, R W; Edgecock, T R; Haywood, S; Edwards, M; Maley, P; Norton, P R; Thompson, J C; Bloch-Devaux, B; Colas, P; Emery, S; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Marx, B; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Trabelsi, A; Vallage, B; Johnson, R P; Kim, H Y; Litke, A M; McNeil, M A; Taylor, G; Beddall, A; Booth, C N; Boswell, R; Cartwright, S L; Combley, F; Dawson, I; Köksal, A; Letho, M; Newton, W M; Rankin, C; Thompson, L F; Böhrer, A; Brandt, S; Cowan, G D; Feigl, E; Grupen, Claus; Lutters, G; Minguet-Rodríguez, J A; Rivera, F; Saraiva, P; Smolik, L; Stephan, F; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Ragusa, F; Rothberg, J E; Wasserbaech, S R; Armstrong, S R; Bellantoni, L; Elmer, P; Feng, Z; Ferguson, D P S; Gao, Y S; González, S; Grahl, J; Harton, J L; Hayes, O J; Hu, H; McNamara, P A; Nachtman, J M; Orejudos, W; Pan, Y B; Saadi, Y; Schmitt, M; Scott, I J; Sharma, V; Turk, J; Walsh, A M; Wu Sau Lan; Wu, X; Yamartino, J M; Zheng, M; Zobernig, G

    1996-01-01

    The mean lifetime of the \\tau lepton is measured in a sample of 25700 \\tau pairs collected in 1992 with the ALEPH detector at LEP. A new analysis of the 1-1 topology events is introduced. In this analysis, the dependence of the impact parameter sum distribution on the daughter track momenta is taken into account, yielding improved precision compared to other impact parameter sum methods. Three other analyses of the one- and three-prong \\tau decays are updated with increased statistics. The measured lifetime is 293.5 \\pm 3.1 \\pm 1.7 \\fs. Including previous (1989--1991) ALEPH measurements, the combined \\tau lifetime is 293.7 \\pm 2.7 \\pm 1.6 \\fs.

  4. Study of voltage decrease in organic light emitting diodes during the initial stage of lifetime

    Science.gov (United States)

    Cusumano, P.

    2016-02-01

    We report the results of lifetime DC testing at constant current of not-encapsulated organic light emitting diodes (OLEDs) based on Tris (8 idroxyquinoline) aluminum (Alq3) as emitting material. In particular, a voltage decrease during the initial stage of the lifetime test is observed. The cause of this behavior is also discussed, mainly linked to initial Joule self-heating of the device, rising its temperature above room temperature until thermal equilibrium is reached at steady state.

  5. Optimal Taxation and Social Insurance in a Lifetime Perspective

    DEFF Research Database (Denmark)

    Bovenberg, A. Lans; Sørensen, Peter Birch

    Advances in information technology have improved the administrative feasibility of redistribution based on lifetime earnings recorded at the time of retirement. We study optimal lifetime income taxation and social insurance in an economy in which redistributive taxation and social insurance serve......-transfer system does not provide full disability insurance. By offering imperfect insurance and structuring disability benefits so as to enable workers to insure against disability by working harder, social insurance is designed to offset the distortionary impact of the redistributive labor income tax on labor...... to insure (ex ante) against skill heterogeneity as well as disability risk. Optimal disability benefits rise with previous earnings so that public transfers depend not only on current earnings but also on earnings in the past. Hence, lifetime taxation rather than annual taxation is optimal. The optimal tax...

  6. DC photoemission electron guns as ERL sources

    International Nuclear Information System (INIS)

    Sinclair, Charles K.

    2006-01-01

    Very-high-voltage DC electron guns, delivering moderate duration bunches from photoemission cathodes, and followed by conventional drift bunching and acceleration, offer a practical solution for an ERL injector. In a variant of this scheme, a DC gun is placed in close proximity to a superconducting RF accelerator cavity, with few or no active elements between the gun and cavity. The principal technical challenge with such electron guns arises from field emission from the cathode electrode and its support structure. Field emission may result in voltage breakdown across the cathode-anode gap, or a punch-through failure of the insulator holding off the cathode potential, as well as lesser though still serious problems. Various means to mitigate these problems are described. The operational lifetime of high quantum efficiency photocathodes in these guns is determined by the vacuum conditions, through phenomena such as chemical poisoning and ion back-bombardment. Minimization of the field strength on electrode structures pushes high-voltage DC guns toward large dimensions and, correspondingly, large outgassing loads, but it is also true that these guns offer many opportunities for achieving excellent vacuum conditions. Good solutions to vacuum problems that had previously limited cathode lifetime have been demonstrated in recent years. Designs for DC guns presently in use and planned for the near future will be described. The parameters necessary for a 100 mA average current, very-high-voltage DC gun with a photocathode operational lifetime greater than 100 h appear to be within reach, but have yet to be demonstrated. A 1 A average current source with good cathode operational lifetime will require developments beyond the present state-of-the-art

  7. Statistical Models and Methods for Lifetime Data

    CERN Document Server

    Lawless, Jerald F

    2011-01-01

    Praise for the First Edition"An indispensable addition to any serious collection on lifetime data analysis and . . . a valuable contribution to the statistical literature. Highly recommended . . ."-Choice"This is an important book, which will appeal to statisticians working on survival analysis problems."-Biometrics"A thorough, unified treatment of statistical models and methods used in the analysis of lifetime data . . . this is a highly competent and agreeable statistical textbook."-Statistics in MedicineThe statistical analysis of lifetime or response time data is a key tool in engineering,

  8. Lifetime assessment and lifetime management for key components of nuclear power plants

    International Nuclear Information System (INIS)

    Dou Yikang; Sun Hanhong; Qu Jiadi

    2000-01-01

    On the bases of investigation on recent development of plant lifetime management in the world, the author gives some points of view on how to establish plant lifetime assessment (PLA) and management (PLM) systems for Chinese nuclear power plants. The main points lie in: 1) safety regulatory organizations, utilities and R and D institutes work cooperatively for PLA and PLM; 2) PLA and PLM make a interdependent cycle, which means that a good PLM system ensures authentic input for PLA, while veritable PLA provides valuable feedback for PLM improvement; 3) PLA and PLM should be initiated for some key components. The author also analyzes some important problems to be tackled in PLA and PLM from the view angle of a R and D institute

  9. Characterization of porcine eyes based on autofluorescence lifetime imaging

    Science.gov (United States)

    Batista, Ana; Breunig, Hans Georg; Uchugonova, Aisada; Morgado, António Miguel; König, Karsten

    2015-03-01

    Multiphoton microscopy is a non-invasive imaging technique with ideal characteristics for biological applications. In this study, we propose to characterize three major structures of the porcine eye, the cornea, crystalline lens, and retina using two-photon excitation fluorescence lifetime imaging microscopy (2PE-FLIM). Samples were imaged using a laser-scanning microscope, consisting of a broadband sub-15 femtosecond (fs) near-infrared laser. Signal detection was performed using a 16-channel photomultiplier tube (PMT) detector (PML-16PMT). Therefore, spectral analysis of the fluorescence lifetime data was possible. To ensure a correct spectral analysis of the autofluorescence lifetime data, the spectra of the individual endogenous fluorophores were acquired with the 16-channel PMT and with a spectrometer. All experiments were performed within 12h of the porcine eye enucleation. We were able to image the cornea, crystalline lens, and retina at multiple depths. Discrimination of each structure based on their autofluorescence intensity and lifetimes was possible. Furthermore, discrimination between different layers of the same structure was also possible. To the best of our knowledge, this was the first time that 2PE-FLIM was used for porcine lens imaging and layer discrimination. With this study we further demonstrated the feasibility of 2PE-FLIM to image and differentiate three of the main components of the eye and its potential as an ophthalmologic technique.

  10. Luminescence lifetimes in natural quartz annealed beyond its second phase inversion temperature

    International Nuclear Information System (INIS)

    Chithambo, M.L.

    2015-01-01

    The influence of annealing, irradiation dose, preheating and measurement temperature on luminescence lifetimes has been studied in quartz annealed at 1000 °C. The measurements were supplemented by studies on quartz annealed at 900 and 800 °C. Lifetimes increase with dose as well as with temperature and duration of annealing between 800 and 1000 °C. Preheating produces the same effect. The changes are accounted for in terms of hole-transfer from the non-radiative luminescence centre to and between radiative centres. The influence of measurement temperature on lifetimes depends on whether the stimulation is carried out from ambient to 200 °C or otherwise. This result is unlike that in quartz annealed at or below 500 °C where lifetimes are independent of the direction of heating. In particular, lifetimes decrease monotonically when measurements are made from 20 to 200 °C but not when recorded from 200 to 20 °C. The latter produces a pattern resembling that in quartz annealed up to 500 °C. The results are concluded as evidence of thermal effects on separate luminescence centres. In support of this, different values of the activation energy for thermal quenching were found for each supposed luminescence centre. The change of the corresponding luminescence intensity with temperature is also qualitatively consistent with this notion. - Highlights: • Luminescence lifetimes in natural quartz annealed beyond its second phase inversion temperature is reported. • Lifetimes increase with dose, annealing between 800 and 1000 °C, and preheating. • Lifetimes under stimulation temperature are affected by direction of heating. • Changes are accounted for in terms of hole-transfer luminescence centres.

  11. c, b, and tau lifetime measurements in e+e- interactions

    International Nuclear Information System (INIS)

    Jaros, J.A.

    1983-01-01

    Experiments at e + e - storage rings have successfully measured the tau and D 0 lifetimes and set interesting limits on the B lifetime. So far, the conventional wisdom has prevailed. The tau lifetime is consistent with prediction; there is no sign (but little sensitivity) of a violation of universality. The charmed particle lifetimes are roughly as expected, but richer in their phenomenology than anticipated. The B lifetime is still unknown. The experimental art is developing rapidly. Several experiments have by now installed vertex detectors. Measurements of charmed particle lifetimes from e + e - experiments will complement the work that has been done at fixed target machines. Measurements of tau and B lifetimes may be the exclusive province of e + e - experiments for the next few years

  12. LHCb: Measurement of $b$-hadron lifetimes at LHCb

    CERN Multimedia

    Amhis, Y

    2014-01-01

    Lifetimes are among the most fundamental properties of elementary particles. Precision Measurements of $b$-hadron lifetimes are an important tool to test theoretical models such as HQET. These models allow to predict various observables related to B-mixing. Using data collected during Run 1 at the LHC, LHCb measured the lifetime of B-decays including a $J/\\psi$ in the final state.

  13. Lifetime earnings for physicians across specialties.

    Science.gov (United States)

    Leigh, J Paul; Tancredi, Daniel; Jerant, Anthony; Romano, Patrick S; Kravitz, Richard L

    2012-12-01

    Earlier studies estimated annual income differences across specialties, but lifetime income may be more relevant given physicians' long-term commitments to specialties. Annual income and work hours data were collected from 6381 physicians in the nationally representative 2004-2005 Community Tracking Study. Data regarding years of residency were collected from AMA FREIDA. Present value models were constructed assuming 3% discount rates. Estimates were adjusted for demographic and market covariates. Sensitivity analyses included 4 alternative models involving work hours, retirement, exogenous variables, and 1% discount rate. Estimates were generated for 4 broad specialty categories (Primary Care, Surgery, Internal Medicine and Pediatric Subspecialties, and Other), and for 41 specific specialties. The estimates of lifetime earnings for the broad categories of Surgery, Internal Medicine and Pediatric Subspecialties, and Other specialties were $1,587,722, $1,099,655, and $761,402 more than for Primary Care. For the 41 specific specialties, the top 3 (with family medicine as reference) were neurological surgery ($2,880,601), medical oncology ($2,772,665), and radiation oncology ($2,659,657). The estimates from models with varying rates of retirement and including only exogenous variables were similar to those in the preferred model. The 1% discount model generated estimates that were roughly 150% larger than the 3% model. There was considerable variation in the lifetime earnings across physician specialties. After accounting for varying residency years and discounting future earnings, primary care specialties earned roughly $1-3 million less than other specialties. Earnings' differences across specialties may undermine health reform efforts to control costs and ensure adequate numbers of primary care physicians.

  14. Lifetime Traumatic Experiences and Leisure Physical Inactivity among Adolescent Boys.

    Science.gov (United States)

    Malinauskas, Romualdas; Malinauskiene, Vilija; Malinauskas, Mindaugas

    2018-03-01

    The aim of this study was to examine the associations between lifetime traumatic experiences and leisure physical inactivity among adolescent boys and to determine to what extent those associations are mediated by posttraumatic stress symptoms, unhealthy behaviors (smoking, alcohol use), the daily consumption of fresh fruit, and sense of coherence. A self-administered questionnaire combining 3 instruments measured leisure physical activity level (Godin and Shephard), symptoms of posttraumatic stress (IES-revised), lifetime traumatic experiences, sense of coherence (SOC-13, from Antonovsky), and behavioral and dietary patterns in a representative sample of eighth grade boys from a number of Kaunas, Lithuania, secondary schools (N = 885; response rate 88.6%). Fifty-six point eight percent of boys had experienced at least 1 lifetime traumatic event, with a 20.5% prevalence of PTS symptoms, and 5.4% were inactive during leisure time. In the logistic regression models, leisure physical inactivity was associated with lifetime traumatic experiences (adjusted OR = 2.33; 95% CI: 1.09-4.98). Sense of coherence and posttraumatic stress symptoms did not mediate those associations. Less-than-daily consumption of fresh fruit showed an independent effect, while smoking and weekly consumption of alcohol did not. Consistent associations between lifetime traumatic experiences and leisure physical inactivity among adolescent boys indicate that the presence of lifetime traumatic events should be taken into account when employing intervention and prevention programs on unhealthy lifestyles (physical inactivity, smoking, and alcohol).

  15. Lifetime measurements of excited Co I levels

    CERN Document Server

    Klotz, W D; Gobel, L H

    1977-01-01

    In the region of 3500 AA the lifetimes of eight excited Cobalt I levels have been measured by means of the zero field level crossing method. The measured lifetimes belong to the odd configurations 3d/sup 7/4s4p and 3d/sup 8/4p and are of the accuracy of about 5%. The hyperfine structure of levels with I not=J has to be taken into account in evaluating lifetimes from level crossing data, because the nuclear spin of the natural isotope /sup 59/Co is I=7/2. Therefore the influence of the line profile of the exciting resonance lines on the lifetimes has been investigated. The results are compared with those of other authors. Furthermore absolute oscillator strengths were calculated with known branching ratios and a new absolute scale has been established. (23 refs).

  16. Experimental lifetimes for Mg-like chlorine

    International Nuclear Information System (INIS)

    Engstroem, L.; Bengtsson, P.; Jupen, C.; Livingston, A.E.; Martinson, I.

    1995-01-01

    The results of beam-foil measurements of lifetimes for low-lying singlet levels in Mg-like chlorine, Cl VI, are presented. The decay curves were analyzed by means of the arbitrarily normalized decay curve method, combined with the recently developed CANYL code, which facilitates studies of decay chains. Cascade corrected data are presented for the levels 3s3p 1 P, 3p 2 1 S, 3p 2 1 D, and 3s3d 1 D, whereas less rigorous lifetime values, based on curve fits, were obtained for the 3p3d 1 D, 3p3d 1 F, and 3s4f 1 F levels. The data are in excellent agreement with recent theoretical values, and previous discrepancies between experiment and theory for short-lived states have been removed

  17. Low lifetime stress exposure is associated with reduced stimulus–response memory

    Science.gov (United States)

    Goldfarb, Elizabeth V.; Shields, Grant S.; Daw, Nathaniel D.; Slavich, George M.; Phelps, Elizabeth A.

    2017-01-01

    Exposure to stress throughout life can cumulatively influence later health, even among young adults. The negative effects of high cumulative stress exposure are well-known, and a shift from episodic to stimulus–response memory has been proposed to underlie forms of psychopathology that are related to high lifetime stress. At the other extreme, effects of very low stress exposure are mixed, with some studies reporting that low stress leads to better outcomes, while others demonstrate that low stress is associated with diminished resilience and negative outcomes. However, the influence of very low lifetime stress exposure on episodic and stimulus–response memory is unknown. Here we use a lifetime stress assessment system (STRAIN) to assess cumulative lifetime stress exposure and measure memory performance in young adults reporting very low and moderate levels of lifetime stress exposure. Relative to moderate levels of stress, very low levels of lifetime stress were associated with reduced use and retention (24 h later) of stimulus–response (SR) associations, and a higher likelihood of using context memory. Further, computational modeling revealed that participants with low levels of stress exhibited worse expression of memory for SR associations than those with moderate stress. These results demonstrate that very low levels of stress exposure can have negative effects on cognition. PMID:28298555

  18. Modeling and optimization of membrane lifetime in dead-end ultra filtration

    NARCIS (Netherlands)

    Zondervan, E.; Roffel, B.

    2008-01-01

    In this paper, a membrane lifetime model is developed and experimentally validated. The lifetime model is based on the Weibull probability density function. The lifetime model can be used to determine an unambiguous characteristic membrane lifetime. Experimental results showed that membrane lifetime

  19. Theoretical spectroscopic studies of the atomic transitions and lifetimes of low-lying states in Ti IV

    International Nuclear Information System (INIS)

    Mandal, Subhasish; Dixit, Gopal; Majumder, Sonjoy; Sahoo, B K; Chaudhuri, R K

    2008-01-01

    The astrophysically important electric quadrupole (E2) and magnetic dipole (M1) transitions for the low-lying states of triply ionized titanium (Ti IV) are calculated very accurately using a state-of-the-art all-order many-body theory called coupled cluster (CC) method in the relativistic framework. Different many-body correlations of the CC theory has been estimated by studying the core and valence electron excitations to the unoccupied states. The calculated excitation energies of different states are in excellent agreement with the measurements. Also, we compare our calculated electric dipole (E1) amplitudes of few transitions with recent many-body calculations by others. The lifetimes of the low-lying states of Ti IV have been estimated and long lifetime is found for the first excited 3d 2 D 5/2 state, which suggested that Ti IV may be one of the useful candidates for many fundamental studies of physics. Most of the forbidden transition results reported here are not available in the literature, to the best of our knowledge

  20. Lifetime tests for MAC vertex chamber

    International Nuclear Information System (INIS)

    Nelson, H.N.

    1986-07-01

    A vertex chamber for MAC was proposed to increase precision in the measurement of the B hadron and tau lepton lifetimes. Thin-walled aluminized mylar drift tubes were used for detector elements. A study of radiation hardness was conducted under the conditions of the proposed design using different gases and different operating conditions

  1. Lifetime for the Ti X spectrum

    International Nuclear Information System (INIS)

    Singh, Jagjit; Jha, A K S; Mohan, M

    2010-01-01

    We present configuration interaction calculations for the lifetime of 294 fine-structure levels of the Ti X spectrum in the LSJ coupling scheme. The calculations include all the major correlation effects. The relativistic effects are included by adding the mass correction term, Darwin term and spin-orbit interaction term to the non-relativistic Hamiltonian in the Breit-Pauli approximation. The calculated lifetime values are in very close agreement with other available experimental and theoretical results. We have predicted new lifetime results for levels belonging to 3p 2 3d, 3s 2 4p, 3s3p4s, 3s3p4p and various other configurations of Ti X, where no other theoretical and experimental results are available.

  2. The neutron lifetime experiment PENeLOPE

    Energy Technology Data Exchange (ETDEWEB)

    Schreyer, Wolfgang [Technische Universitaet Muenchen (Germany); Collaboration: PENeLOPE-Collaboration

    2015-07-01

    The neutron lifetime τ{sub n}=880.3±1.1 s is an important parameter in the Standard Model of particle physics and in Big Bang cosmology. Several systematic corrections of previously published results reduced the PDG world average by several σ in the last years and call for a new experiment with complementary systematics. The experiment PENeLOPE, currently under construction at the Physik-Department of Technische Universitaet Muenchen, aims to determine the neutron lifetime with a precision of 0.1 s. It will trap ultra-cold neutrons in a magneto-gravitational trap using a large superconducting magnet and will measure their lifetime by both neutron counting and online proton detection. This presentation gives an overview over the latest developments of the experiment.

  3. Effect of Junction Temperature Swing Durations on a Lifetime of a Transfer Molded IGBT Module

    DEFF Research Database (Denmark)

    Choi, Uimin; Blaabjerg, Frede; Jorgensen, Soren

    2016-01-01

    results under 6 different conditions and it may improve a lifetime model for lifetime prediction of IGBT modules under various mission profiles of converters. The power cycling tests are performed by an advanced power cycling test setup which enables tested modules to be operated under more realistic......In this paper, the effect of junction temperature swing duration on the lifetime of a transfer molded Intelligent Power IGBT Module is studied and a relevant lifetime factor is modeled. A temperature swing duration dependent lifetime factor is defined based on 38 accelerated power cycling test...

  4. Optimizing design of converters using power cycling lifetime models

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Ørndrup; Munk-Nielsen, Stig

    2015-01-01

    Converter power cycling lifetime depends heavily on converter operation point. A lifetime model of a single power module switched mode power supply with wide input voltage range is shown. A lifetime model is created using a power loss model, a thermal model and a model for power cycling capability...... with a given mission profile. A method to improve the expected lifetime of the converter is presented, taking into account switching frequency, input voltage and transformer turns ratio....

  5. Positron annihilation lifetime study of extended defects in semiconductor glasses and polymers

    Energy Technology Data Exchange (ETDEWEB)

    Boyko, Olha [Department of Pediatric Dentistry, Danylo Halytsky Lviv National Medical University, Pekarska str. 69, 79010 Lviv (Ukraine); Shpotyuk, Yaroslav [Department of Optoelectronics and Information Technologies, Ivan Franko National University of Lviv, Dragomanova str. 50, 79005 Lviv (Ukraine); Lviv Scientific Research Institute of Materials, Scientific Research Company ' ' Carat' ' , Stryjska str. 202, 79031 Lviv (Ukraine); Filipecki, Jacek [Institute of Physics, Jan Dlugosz University in Czestochowa, Armii Krajowej al. 13/15, 42200 Czestochowa (Poland)

    2013-01-15

    The processes of atomic shrinkage in network-forming solids initiated by external influences are tested using technique of positron annihilation lifetime spectroscopy at the example of chalcogenide vitreous semiconductors of arsenic sulphide type and acrylic polymers for dental application. Two state positron trapping is shown to be responsible for atomic shrinkage in chalcogenide glasses, while mixed trapping and ortho-positronium decaying is character for volumetric densification and stress propagation in acrylic dental polymers. At the basis of the obtained results it is concluded that correct analysis of externally-induced shrinkage in polymer networks under consideration can be developed by using original positron lifetime data treatment algorithms to compensate defect-free bulk annihilation channel within two-state positron trapping model and account for an interbalance between simultaneously co-existing positron trapping and orth-positronium related decaying channels within mixed three-state positron annihilation model (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  6. Positron annihilation lifetime study of extended defects in semiconductor glasses and polymers

    International Nuclear Information System (INIS)

    Boyko, Olha; Shpotyuk, Yaroslav; Filipecki, Jacek

    2013-01-01

    The processes of atomic shrinkage in network-forming solids initiated by external influences are tested using technique of positron annihilation lifetime spectroscopy at the example of chalcogenide vitreous semiconductors of arsenic sulphide type and acrylic polymers for dental application. Two state positron trapping is shown to be responsible for atomic shrinkage in chalcogenide glasses, while mixed trapping and ortho-positronium decaying is character for volumetric densification and stress propagation in acrylic dental polymers. At the basis of the obtained results it is concluded that correct analysis of externally-induced shrinkage in polymer networks under consideration can be developed by using original positron lifetime data treatment algorithms to compensate defect-free bulk annihilation channel within two-state positron trapping model and account for an interbalance between simultaneously co-existing positron trapping and orth-positronium related decaying channels within mixed three-state positron annihilation model (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  7. Lifetime sedentary living accelerates some aspects of secondary aging

    DEFF Research Database (Denmark)

    Booth, Frank W; Laye, Matthew J; Roberts, Michael D

    2011-01-01

    accelerates secondary aging (e.g., speeding the reduction in bone mineral density, maximal oxygen consumption, and skeletal muscle strength and power), but does not alter the primary aging of these systems. Third, a lifetime of physical activity to the age of ∼60-70 yr old totally prevents decrements in some...... role in the secondary aging of many essential physiological functions, and this aging can be prevented through a lifetime of physical activity.......Lifetime physical inactivity interacts with secondary aging (i.e., aging caused by diseases and environmental factors) in three patterns of response. First, lifetime physical inactivity confers no apparent effects on a given set of physiological functions. Second, lifetime physical inactivity...

  8. Positronium formation in NaY-zeolites studied by lifetime, positron beam Doppler broadening and 3-gamma detection techniques

    CERN Document Server

    Schut, H; Kolar, Z I; Veen, A V; Clet, G

    2000-01-01

    Results of positron annihilation measurements on NaY pressed powders and deposited thin films using slow positron beam and conventional fast positron techniques are presented. In lifetime experiments using an external sup sup 2 sup sup 2 Na source an averaged long lifetime of 1.8 ns with a sum intensity of 27% was observed in pressed powders in the presence of air at room temperature (RT). In literature this lifetime is ascribed to positrons annihilating in water filled alpha or beta cages Habrowska, A.M., Popiel, E.S., 1987. Positron annihilation in zeolite 13X. J. Appl. Phys. 62, 2419. By means of isotopic exchange some of the Na was replaced by sup sup 2 sup sup 2 Na. These powders showed a long lifetime component of 7-8 ns with an intensity increasing from 1 to 12% when heated under normal atmosphere from RT to 200 deg. C. No significant increase of the shorter (1.5 ns) lifetime was observed, while its intensity dropped from 13.4 to 6.6%. Both effects are ascribed to the loss of water from alpha cages onl...

  9. Contribution of lifetime smoking habit in France and Northern Ireland to country and socioeconomic differentials in mortality and cardiovascular incidence: the PRIME Study.

    Science.gov (United States)

    Yarnell, J W G; Patterson, C C; Arveiler, D; Amouyel, P; Ferrières, J; Woodside, J V; Haas, B; Montaye, M; Ruidavets, J B; Kee, F; Evans, A; Bingham, A; Ducimetière, P

    2012-07-01

    This study examines the contribution of lifetime smoking habit to the socioeconomic gradient in all-cause and smoking-related mortality and in cardiovascular incidence in two countries. 10,600 men aged 50-59 years were examined in 1991-4 in centres in Northern Ireland and France and followed annually for 10 years. Deaths and cardiovascular events were documented. Current smoking habit, lifetime smoking (pack-years) and other health behaviours were evaluated at baseline. As socio-occupational coding schemes differ between the countries seven proxy socioeconomic indicators were used. Lifetime smoking habit showed marked associations with most socioeconomic indicators in both countries, but lifetime smoking was more than 10 pack-years greater overall in Northern Ireland and smoking patterns differed. Total mortality was 49% higher in Northern Ireland than in France, and smoking-related mortality and cardiovascular incidence were 93% and 92% higher, respectively. Both lifetime smoking and fibrinogen contributed independently to these differentials, but together explained only 42% of the difference in total mortality between countries, adjusted for both biological and lifestyle confounders. Socioeconomic gradients were steeper for total and smoking-related mortality than for cardiovascular incidence. Residual contributions of lifetime smoking habit ranged from 6% to 34% for the seven proxy indicators of socioeconomic position for total and smoking-related mortality. Socioeconomic gradients in cardiovascular incidence were minimal following adjustment for confounders. In Northern Ireland and France lifetime smoking appeared to explain a significant part of the gradients in total and smoking-related mortality between socioeconomic groups, but the contribution of smoking was generally small for cardiovascular incidence.

  10. Nanoparticle discrimination based on wavelength and lifetime-multiplexed cathodoluminescence microscopy.

    Science.gov (United States)

    Garming, Mathijs W H; Weppelman, I Gerward C; de Boer, Pascal; Martínez, Felipe Perona; Schirhagl, Romana; Hoogenboom, Jacob P; Moerland, Robert J

    2017-08-31

    Nanomaterials can be identified in high-resolution electron microscopy images using spectrally-selective cathodoluminescence. Capabilities for multiplex detection can however be limited, e.g., due to spectral overlap or availability of filters. Also, the available photon flux may be limited due to degradation under electron irradiation. Here, we demonstrate single-pass cathodoluminescence-lifetime based discrimination of different nanoparticles, using a pulsed electron beam. We also show that cathodoluminescence lifetime is a robust parameter even when the nanoparticle cathodoluminescence intensity decays over an order of magnitude. We create lifetime maps, where the lifetime of the cathodoluminescence emission is correlated with the emission intensity and secondary-electron images. The consistency of lifetime-based discrimination is verified by also correlating the emission wavelength and the lifetime of nanoparticles. Our results show how cathodoluminescence lifetime provides an additional channel of information in electron microscopy.

  11. Lifetime income inequality with taxation and public benefits

    OpenAIRE

    Kemptner, Daniel; Haan, Peter; Prowse, Victoria

    2016-01-01

    In this paper, we show how taxation, unemployment insurance, welfare, disability benefits and public pensions affect the inequality of lifetime income. Using results from a dynamic life-cycle model estimated using German panel data, we show that taxation and public benefits combined reduce the inequality of lifetime income, measured by the Gini coefficient, by 22\\%. Pensions only slightly reduce inequality in lifetime income. Welfare benefits, meanwhile, make persistent transfers to individua...

  12. Possible evidence for the quantization of particle lifetimes

    International Nuclear Information System (INIS)

    Ehrlich, R.

    1976-01-01

    An analysis of widths of resonant states supports the hypothesis that particle lifetimes are quantized in units of 1/2 or possibly 1/4 the lifetime of the rho meson: (4.40 +- 0.06) x 10 -24 seconds. The probability that the observed regularity in resonance widths (lifetimes) is simply due to chance is estimated to be less than 2 x 10 -4 . Possible ramifications of this result are considered

  13. Lifetime physical inactivity is associated with increased risk for Hodgkin and non-Hodgkin lymphoma: A case-control study.

    Science.gov (United States)

    Etter, John Lewis; Cannioto, Rikki; Soh, Kah Teong; Alquassim, Emad; Almohanna, Hani; Dunbar, Zachary; Joseph, Janine M; Balderman, Sophia; Hernandez-Ilizaliturri, Francisco; Moysich, Kirsten B

    2018-03-27

    Although physical activity is a well-established risk factor for several cancer types, studies evaluating its association with lymphoma have yielded inconclusive results. In such cases where physical activity is not clearly associated with cancer risk in a dose-dependent manner, investigators have begun examining physical inactivity as an independent exposure of interest. Associations of self-reported, lifetime physical inactivity with risk of developing Hodgkin lymphoma (HL) and non-Hodgkin lymphoma (NHL) were evaluated in a hospital-based case control study using data from the Patient Epidemiology Data System at Roswell Park Comprehensive Cancer Center. Participants included 87 patients with HL and 236 patients with NHL as well as 348 and 952 cancer-free controls, respectively. Multivariable-adjusted logistic regression models were fit to calculate odds ratios (OR) and 95% confidence intervals (CI) estimating the association between physical inactivity and lymphoma risk. We observed significant, positive associations between lifetime recreational physical inactivity and risk of both HL (OR = 1.90, 95% CI: 1.15-3.15) and NHL (OR = 1.35, 95% CI: 1.01-1.82). The current analysis provides evidence for a positive association between physical inactivity and risk of both HL and NHL. These results add to a growing body of research suggesting that lifetime physical inactivity may be an important independent, modifiable behavioral risk factor for cancer. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Λc photoproduction and lifetime measurement

    International Nuclear Information System (INIS)

    Amendolia, S.R.; Bagliesi, G.; Batignani, G.; Bertolucci, E.; Bettoni, D.; Bizetti, A.; Bosisio, L.; Bottigli, U.; Bradaschia, C.; Dell'Orso, M.; Fidecaro, F.; Foa, L.; Focardi, E.; Giannetti, P.; Giorgi, M.A.; Marrocchesi, P.S.; Menzione, A.; Raso, G.; Ristori, L.; Scribano, A.; Stefanini, A.; Tenchini, R.; Tonelli, G.; Triggiani, G.; Beck, G.A.; Bologna, G.; D'Ettorre Piazzoli, B.; Picchi, P.; Budinich, M.; Liello, F.; Milotti, E.; Rolandi, L.; Carter, J.; Green, M.G.; Landon, M.P.J.; March, P.V.; Sacks, L.; Sanjari, A.H.; Strong, J.A.; Ciocci, M.A.; Enorini, M.; Fabbri, F.L.; Laurelli, P.; Mannocchi, G.; Simonelli, L.; Spillantini, P.; Zallo, A.

    1987-01-01

    A measurement of the lifetime of the Λ c baryon photoproduced coherently of a germanium-silicon target is presented. A signal of Λ c → ΔΚ * → pKππ 0 has been observed and the two different decay diagrams for this process are compared. A sample of 9 Λ c decays give a lifetime of 1.1(+0.8-0.4)10 13 s. (orig.)

  15. Baselines for Lifetime of Organic Solar Cells

    DEFF Research Database (Denmark)

    Gevorgyan, Suren; Espinosa Martinez, Nieves; Ciammaruchi, Laura

    2016-01-01

    The process of accurately gauging lifetime improvements in organic photovoltaics (OPVs) or other similar emerging technologies, such as perovskites solar cells is still a major challenge. The presented work is part of a larger effort of developing a worldwide database of lifetimes that can help...

  16. Digital positron lifetime spectroscopy: present status and outlook

    International Nuclear Information System (INIS)

    Becvar, F.

    2007-01-01

    This contribution summarizes achievements in instrumentation for positron lifetime measurements with emphasis on digital spectrometric systems. A significant part of the data presented are based on a long-term exploitation of a conventional positron lifetime spectrometer developed at Charles University in early 90s, on bench-mark testing measurements with this spectrometer working temporarily in conjunction with a pair of 8-bit, 4 GS/s digitizers and on analogous measurements with a recently assembled digital positron lifetime spectrometer. In addition, results from testing experiments with microchannel plate photomultipliers are briefly reported. Further development of positron lifetime technique is discussed. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  17. Temperature dependence of the luminescence lifetime of a europium complex immobilized in different polymer matrices

    Energy Technology Data Exchange (ETDEWEB)

    Basu, Bharathi Bai J. [Surface Engineering Division, National Aerospace Laboratories, Bangalore 560017 (India)], E-mail: bharathi@css.nal.res.in; Vasantharajan, N. [Surface Engineering Division, National Aerospace Laboratories, Bangalore 560017 (India)

    2008-10-15

    The temperature dependence of the luminescence lifetime of temperature sensor films based on europium (III) thenoyltrifluoroacetonate (EuTTA) as sensor dye in various polymer matrices such as polystyrene (PS), polymethylmethacrylate (PMMA), polyurethane (PU) and model airplane dope was studied and compared. The luminescence lifetime of EuTTA was found to depend on the polymer matrix. The temperature sensitivity of lifetime was maximum for EuTTA-PS coating in the temperature range of 10-60 deg. C. The effect of concentration of the sensor dye in the polymer on the lifetime and temperature sensitivity was also studied.

  18. Vacancy defects in electron irradiated RPV steels studied by positron lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Moser, P; Li, X H [CEA Centre d` Etudes de Grenoble, 38 (France). Dept. de Recherche Fondamentale sur la Matiere Condensee; Akamatsu, M; Van Duysen, J C [Electricite de France (EDF), 77 - Ecuelles (France)

    1994-12-31

    Specimens of French RPV (reactor pressure vessels) steels at different rates of segregation have been irradiated at 150 and 288 deg C with 3 MeV electrons (irradiation dose: 4*10{sup 19} e-/cm{sup 2}). Vacancy defects are studied by positron lifetime measurements before and after irradiation and at each step of isochronal annealing. After 150 deg C irradiation, a recovery step is observed in both specimens, for annealing treatments in the range 220-370 deg C and is attributed to the dissociation of vacancy-impurity complexes. The size of vacancy clusters never overcome 10 empty atomic volumes. If ``fresh`` dislocations are created just before irradiation, big vacancy clusters could be formed. After 288 deg C irradiation, small vacancy cluster of 4-10 empty atomic volumes are observed. (authors). 3 figs., 7 refs.

  19. Estimation of average causal effect using the restricted mean residual lifetime as effect measure

    DEFF Research Database (Denmark)

    Mansourvar, Zahra; Martinussen, Torben

    2017-01-01

    with respect to their survival times. In observational studies where the factor of interest is not randomized, covariate adjustment is needed to take into account imbalances in confounding factors. In this article, we develop an estimator for the average causal treatment difference using the restricted mean...... residual lifetime as target parameter. We account for confounding factors using the Aalen additive hazards model. Large sample property of the proposed estimator is established and simulation studies are conducted in order to assess small sample performance of the resulting estimator. The method is also......Although mean residual lifetime is often of interest in biomedical studies, restricted mean residual lifetime must be considered in order to accommodate censoring. Differences in the restricted mean residual lifetime can be used as an appropriate quantity for comparing different treatment groups...

  20. Positron lifetime measurements as a non-destructive technique to monitor fatigue damage

    International Nuclear Information System (INIS)

    Byrne, J.G.

    1975-09-01

    In the fatigue cycling of initially hard copper, self consistent positron lifetime and x-ray particle size measurements followed the softening process and revealed a new feature which may be the final development of microvoids before fracture. In the cyclic fatigue of initially soft 4340 steel closely spaced concurrent measurements of these parameters are now in progress. For initially hard 4340 steel fatigue softening was revealed with a large positron lifetime decrease. In hydrogen embrittlement studies positron lifetime was found to be sensitive to hydrogen in an interesting way, i.e., if a specimen is already at its maximum defect density, hydrogen is trapped at some of the defects, reduce their attraction for positrons and hence cause a decrease in positron lifetime; conversely in a soft specimen, hydrogen generates more dislocation length than it can trap at (thus cancelling) hence a positron lifetime increase occurs. In electron irradiated and annealed single crystal copper 4 annealing peaks were seen at 125, 270, 400, and 650 0 K. A clear correlation between decreasing positron lifetime and increasing percent porosity in α alumina was established. This behavior is quite []he opposite to that in metals. (auth)