  1. Reproducibility of MR-based Attenuation Maps in PET/MRI and the Impact on PET Quantification in Lung Cancer

    DEFF Research Database (Denmark)

    Olin, Anders; Ladefoged, Claes N; Langer, Natasha H

    2018-01-01

    AIM: Quantitative positron emission tomography/magnetic resonance imaging (PET/MRI) is dependent upon reliable and reproducible MR-based attenuation correction (MR-AC). In this study we evaluated the quality of current vendor-provided thoracic MR-AC maps, and further investigated...... affecting the reproducibility of PET/MRI. This, in combination with other well-known sources of error associated with PET/MRI examinations, leads to inconsistent SUV measurements in serial studies and follow-up scenarios, which may affect the reliability of therapy response assessment. A thorough visual...

  2. Reproducibility of 5-HT2A receptor measurements and sample size estimations with [18F]altanserin PET using a bolus/infusion approach

    DEFF Research Database (Denmark)

    Haugbøl, Steven; Pinborg, Lars H; Arfan, Haroon M

    2006-01-01

    PURPOSE: To determine the reproducibility of measurements of brain 5-HT2A receptors with an [18F]altanserin PET bolus/infusion approach. Further, to estimate the sample size needed to detect regional differences between two groups and, finally, to evaluate how partial volume correction affects...... reproducibility and the required sample size. METHODS: For assessment of the variability, six subjects were investigated with [18F]altanserin PET twice, at an interval of less than 2 weeks. The sample size required to detect a 20% difference was estimated from [18F]altanserin PET studies in 84 healthy subjects....... Regions of interest were automatically delineated on co-registered MR and PET images. RESULTS: In cortical brain regions with a high density of 5-HT2A receptors, the outcome parameter (binding potential, BP1) showed high reproducibility, with a median difference between the two group measurements of 6...

  3. Reproducibility of 5-HT2A receptor measurements and sample size estimations with [18F]altanserin PET using a bolus/infusion approach

    International Nuclear Information System (INIS)

    Haugboel, Steven; Pinborg, Lars H.; Arfan, Haroon M.; Froekjaer, Vibe M.; Svarer, Claus; Knudsen, Gitte M.; Madsen, Jacob; Dyrby, Tim B.

    2007-01-01

    To determine the reproducibility of measurements of brain 5-HT 2A receptors with an [ 18 F]altanserin PET bolus/infusion approach. Further, to estimate the sample size needed to detect regional differences between two groups and, finally, to evaluate how partial volume correction affects reproducibility and the required sample size. For assessment of the variability, six subjects were investigated with [ 18 F]altanserin PET twice, at an interval of less than 2 weeks. The sample size required to detect a 20% difference was estimated from [ 18 F]altanserin PET studies in 84 healthy subjects. Regions of interest were automatically delineated on co-registered MR and PET images. In cortical brain regions with a high density of 5-HT 2A receptors, the outcome parameter (binding potential, BP 1 ) showed high reproducibility, with a median difference between the two group measurements of 6% (range 5-12%), whereas in regions with a low receptor density, BP 1 reproducibility was lower, with a median difference of 17% (range 11-39%). Partial volume correction reduced the variability in the sample considerably. The sample size required to detect a 20% difference in brain regions with high receptor density is approximately 27, whereas for low receptor binding regions the required sample size is substantially higher. This study demonstrates that [ 18 F]altanserin PET with a bolus/infusion design has very low variability, particularly in larger brain regions with high 5-HT 2A receptor density. Moreover, partial volume correction considerably reduces the sample size required to detect regional changes between groups. (orig.)

  4. On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners.

    Science.gov (United States)

    Chen, Kevin T; Izquierdo-Garcia, David; Poynton, Clare B; Chonde, Daniel B; Catana, Ciprian

    2017-03-01

    To propose an MR-based method for generating continuous-valued head attenuation maps and to assess its accuracy and reproducibility. Demonstrating that novel MR-based photon attenuation correction methods are both accurate and reproducible is essential prior to using them routinely in research and clinical studies on integrated PET/MR scanners. Continuous-valued linear attenuation coefficient maps ("μ-maps") were generated by combining atlases that provided the prior probability of voxel positions belonging to a certain tissue class (air, soft tissue, or bone) and an MR intensity-based likelihood classifier to produce posterior probability maps of tissue classes. These probabilities were used as weights to generate the μ-maps. The accuracy of this probabilistic atlas-based continuous-valued μ-map ("PAC-map") generation method was assessed by calculating the voxel-wise absolute relative change (RC) between the MR-based and scaled CT-based attenuation-corrected PET images. To assess reproducibility, we performed pair-wise comparisons of the RC values obtained from the PET images reconstructed using the μ-maps generated from the data acquired at three time points. The proposed method produced continuous-valued μ-maps that qualitatively reflected the variable anatomy in patients with brain tumor and agreed well with the scaled CT-based μ-maps. The absolute RC comparing the resulting PET volumes was 1.76 ± 2.33 %, quantitatively demonstrating that the method is accurate. Additionally, we also showed that the method is highly reproducible, the mean RC value for the PET images reconstructed using the μ-maps obtained at the three visits being 0.65 ± 0.95 %. Accurate and highly reproducible continuous-valued head μ-maps can be generated from MR data using a probabilistic atlas-based approach.

  5. On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Kevin T. [Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, MA (United States); Massachusetts Institute of Technology, Division of Health Sciences and Technology, Cambridge, MA (United States); Izquierdo-Garcia, David; Catana, Ciprian [Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, MA (United States); Poynton, Clare B. [Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, MA (United States); Massachusetts General Hospital, Department of Psychiatry, Boston, MA (United States); University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Chonde, Daniel B. [Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, MA (United States); Harvard University, Program in Biophysics, Cambridge, MA (United States)

    2017-03-15

    To propose an MR-based method for generating continuous-valued head attenuation maps and to assess its accuracy and reproducibility. Demonstrating that novel MR-based photon attenuation correction methods are both accurate and reproducible is essential prior to using them routinely in research and clinical studies on integrated PET/MR scanners. Continuous-valued linear attenuation coefficient maps (''μ-maps'') were generated by combining atlases that provided the prior probability of voxel positions belonging to a certain tissue class (air, soft tissue, or bone) and an MR intensity-based likelihood classifier to produce posterior probability maps of tissue classes. These probabilities were used as weights to generate the μ-maps. The accuracy of this probabilistic atlas-based continuous-valued μ-map (''PAC-map'') generation method was assessed by calculating the voxel-wise absolute relative change (RC) between the MR-based and scaled CT-based attenuation-corrected PET images. To assess reproducibility, we performed pair-wise comparisons of the RC values obtained from the PET images reconstructed using the μ-maps generated from the data acquired at three time points. The proposed method produced continuous-valued μ-maps that qualitatively reflected the variable anatomy in patients with brain tumor and agreed well with the scaled CT-based μ-maps. The absolute RC comparing the resulting PET volumes was 1.76 ± 2.33 %, quantitatively demonstrating that the method is accurate. Additionally, we also showed that the method is highly reproducible, the mean RC value for the PET images reconstructed using the μ-maps obtained at the three visits being 0.65 ± 0.95 %. Accurate and highly reproducible continuous-valued head μ-maps can be generated from MR data using a probabilistic atlas-based approach. (orig.)

  6. Reproducibility of tumor uptake heterogeneity characterization through textural feature analysis in 18F-FDG PET.

    Science.gov (United States)

    Tixier, Florent; Hatt, Mathieu; Le Rest, Catherine Cheze; Le Pogam, Adrien; Corcos, Laurent; Visvikis, Dimitris

    2012-05-01

    (18)F-FDG PET measurement of standardized uptake value (SUV) is increasingly used for monitoring therapy response and predicting outcome. Alternative parameters computed through textural analysis were recently proposed to quantify the heterogeneity of tracer uptake by tumors as a significant predictor of response. The primary objective of this study was to evaluate the reproducibility of these heterogeneity measurements. Double baseline (18)F-FDG PET scans were acquired within 4 d of each other for 16 patients before any treatment was considered. A Bland-Altman analysis was performed on 8 parameters based on histogram measurements and 17 parameters based on textural heterogeneity features after discretization with values between 8 and 128. The reproducibility of maximum and mean SUV was similar to that in previously reported studies, with a mean percentage difference of 4.7% ± 19.5% and 5.5% ± 21.2%, respectively. By comparison, better reproducibility was measured for some textural features describing local heterogeneity of tracer uptake, such as entropy and homogeneity, with a mean percentage difference of -2% ± 5.4% and 1.8% ± 11.5%, respectively. Several regional heterogeneity parameters such as variability in the intensity and size of regions of homogeneous activity distribution had reproducibility similar to that of SUV measurements, with 95% confidence intervals of -22.5% to 3.1% and -1.1% to 23.5%, respectively. These parameters were largely insensitive to the discretization range. Several parameters derived from textural analysis describing heterogeneity of tracer uptake by tumors on local and regional scales had reproducibility similar to or better than that of simple SUV measurements. These reproducibility results suggest that these (18)F-FDG PET-derived parameters, which have already been shown to have predictive and prognostic value in certain cancer models, may be used to monitor therapy response and predict patient outcome.

  7. The Kinetics and Reproducibility of 18F-Sodium Fluoride for Oncology Using Current PET Camera Technology

    Science.gov (United States)

    Kurdziel, Karen A.; Shih, Joanna H.; Apolo, Andrea B.; Lindenberg, Liza; Mena, Esther; McKinney, Yolanda; Adler, Stephen S.; Turkbey, Baris; Dahut, William; Gulley, James L.; Madan, Ravi A.; Landgren, Ola; Choyke, Peter L.

    2012-01-01

    We evaluated the kinetics of 18F-sodium fluoride (NaF) and reassessed the recommended dose, optimal uptake period, and reproducibility using a current-generation PET/CT scanner. Methods In this prospective study, 73 patients (31 patients with multiple myeloma or myeloma precursor disease and 42 with prostate cancer) were injected with a mean administered dose of 141 MBq of 18F-NaF. Sixty patients underwent 3 sequential sessions of 3-dimensional PET/CT of the torso beginning ~15 min after 18F-NaF injection, followed by a whole-body 3-dimensional PET/CT at 2 h. The remaining 13 prostate cancer patients were imaged only at 2 and 3 h after injection. Twenty-one prostate cancer patients underwent repeat baseline studies (mean interval, 5.9 d) to evaluate reproducibility. Results The measured effective dose was 0.017 mSv/MBq, with the urinary bladder, osteogenic cells, and red marrow receiving the highest doses at 0.080, 0.077, and 0.028 mGy/MBq, respectively. Visual analysis showed that uptake in both normal and abnormal bone increased with time; however, the rate of increase decreased with time. A semiautomated workflow provided objective uptake parameters, including the mean standardized uptake value of all pixels within bone with SUVs greater than 10 and the average of the mean SUV of all malignant lesions identified by the algorithm. The values of these parameters for the images beginning at ~15 min and ~35 min were significantly different (0.3% change/minute). Differences between the later imaging time points were not significant (P 0.9) and relatively low critical percent change (the value above which a change can be considered real) for these parameters. The tumor-to-normal bone ratio, based on the SUVmax of identified malignant lesions, decreased with time; however, this difference was small, estimated at ~0.16%/min in the first hour. Conclusion 18F-NaF PET/CT images obtained with modest radiation exposures can result in highly reproducible imaging parameters

  8. Reproducibility of F18-FDG PET radiomic features for different cervical tumor segmentation methods, gray-level discretization, and reconstruction algorithms.

    Science.gov (United States)

    Altazi, Baderaldeen A; Zhang, Geoffrey G; Fernandez, Daniel C; Montejo, Michael E; Hunt, Dylan; Werner, Joan; Biagioli, Matthew C; Moros, Eduardo G

    2017-11-01

    Site-specific investigations of the role of radiomics in cancer diagnosis and therapy are emerging. We evaluated the reproducibility of radiomic features extracted from 18 Flourine-fluorodeoxyglucose ( 18 F-FDG) PET images for three parameters: manual versus computer-aided segmentation methods, gray-level discretization, and PET image reconstruction algorithms. Our cohort consisted of pretreatment PET/CT scans from 88 cervical cancer patients. Two board-certified radiation oncologists manually segmented the metabolic tumor volume (MTV 1 and MTV 2 ) for each patient. For comparison, we used a graphical-based method to generate semiautomated segmented volumes (GBSV). To address any perturbations in radiomic feature values, we down-sampled the tumor volumes into three gray-levels: 32, 64, and 128 from the original gray-level of 256. Finally, we analyzed the effect on radiomic features on PET images of eight patients due to four PET 3D-reconstruction algorithms: maximum likelihood-ordered subset expectation maximization (OSEM) iterative reconstruction (IR) method, fourier rebinning-ML-OSEM (FOREIR), FORE-filtered back projection (FOREFBP), and 3D-Reprojection (3DRP) analytical method. We extracted 79 features from all segmentation method, gray-levels of down-sampled volumes, and PET reconstruction algorithms. The features were extracted using gray-level co-occurrence matrices (GLCM), gray-level size zone matrices (GLSZM), gray-level run-length matrices (GLRLM), neighborhood gray-tone difference matrices (NGTDM), shape-based features (SF), and intensity histogram features (IHF). We computed the Dice coefficient between each MTV and GBSV to measure segmentation accuracy. Coefficient values close to one indicate high agreement, and values close to zero indicate low agreement. We evaluated the effect on radiomic features by calculating the mean percentage differences (d¯) between feature values measured from each pair of parameter elements (i.e. segmentation methods: MTV

  9. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  10. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  11. Interpretation criteria for FDG PET/CT in multiple myeloma (IMPeTUs): final results. IMPeTUs (Italian myeloma criteria for PET USe).

    Science.gov (United States)

    Nanni, Cristina; Versari, Annibale; Chauvie, Stephane; Bertone, Elisa; Bianchi, Andrea; Rensi, Marco; Bellò, Marilena; Gallamini, Andrea; Patriarca, Francesca; Gay, Francesca; Gamberi, Barbara; Ghedini, Pietro; Cavo, Michele; Fanti, Stefano; Zamagni, Elena

    2018-05-01

    ᅟ: FDG PET/CT ( 18 F-fluoro-deoxy-glucose positron emission tomography/computed tomography) is a useful tool to image multiple myeloma (MM). However, simple and reproducible reporting criteria are still lacking and there is the need for harmonization. Recently, a group of Italian nuclear medicine experts defined new visual descriptive criteria (Italian Myeloma criteria for Pet Use: IMPeTUs) to standardize FDG PET/CT evaluation in MM patients. The aim of this study was to assess IMPeTUs reproducibility on a large prospective cohort of MM patients. Patients affected by symptomatic MM who had performed an FDG PET/CT at baseline (PET0), after induction (PET-AI), and the end of treatment (PET-EoT) were prospectively enrolled in a multicenter trial (EMN02)(NCT01910987; MMY3033). After anonymization, PET images were uploaded in the web platform WIDEN® and hence distributed to five expert nuclear medicine reviewers for a blinded independent central review according to the IMPeTUs criteria. Consensus among reviewers was measured by the percentage of agreement and the Krippendorff's alpha. Furthermore, on a patient-based analysis, the concordance among all the reviewers in terms of positivity or negativity of the FDG PET/CT scan was tested for different thresholds of positivity (Deauville score (DS 2, 3, 4, 5) for the main parameters (bone marrow, focal score, extra-medullary disease). Eighty-six patients (211 FDG PET/CT scans) were included in this analysis. Median patient age was 58 years (range, 35-66 years), 45% were male, 15% of them were in stage ISS (International Staging System) III, and 42% had high-risk cytogenetics. The percentage agreement was superior to 75% for all the time points, reaching 100% of agreement in assessing the presence skull lesions after therapy. Comparable results were obtained when the agreement analysis was performed using the Krippendorff's alpha coefficient, either in every single time point of scanning (PET0, PET-AI or PET-EoT) or

  12. Myocardial blood flow quantification by Rb-82 cardiac PET/CT: A detailed reproducibility study between two semi-automatic analysis programs.

    OpenAIRE

    Dunet, V.; Klein, R.; Allenbach, G.; Renaud, J.; deKemp, R.A.; Prior, J.O.

    2016-01-01

    Background Several analysis software packages for myocardial blood flow (MBF) quantification from cardiac PET studies exist, but they have not been compared using concordance analysis, which can characterize precision and bias separately. Reproducible measurements are needed for quantification to fully develop its clinical potential. Methods Fifty-one patients underwent dynamic Rb-82 PET at rest and during adenosine stress. Data were processed with PMOD and FlowQuant (Lortie model). MBF and m...

  13. Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System

    Directory of Open Access Journals (Sweden)

    Martin L. Lassen

    2017-07-01

    Full Text Available The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic parameters as a function of PET system choice have been investigated. Five healthy volunteers underwent dynamic (R-[11C]verapamil imaging on the same day using a GE-Advance (PET-only and a Siemens Biograph mMR system (PET/MR. PET-emission data were reconstructed using a transmission-based attenuation correction (AC map (PET-only, whereas a standard MR-DIXON as well as a low-dose CT AC map was applied to PET/MR emission data. Kinetic modeling based on arterial blood sampling was performed using a 1-tissue-2-rate constant compartment model, yielding kinetic parameters (K1 and k2 and distribution volume (VT. Differences for parametric values obtained in the PET-only and the PET/MR systems were analyzed using a 2-way Analysis of Variance (ANOVA. Comparison of DIXON-based AC (PET/MR with emission data derived from the PET-only system revealed average inter-system differences of −33 ± 14% (p < 0.05 for the K1 parameter and −19 ± 9% (p < 0.05 for k2. Using a CT-based AC for PET/MR resulted in slightly lower systematic differences of −16 ± 18% for K1 and −9 ± 10% for k2. The average differences in VT were −18 ± 10% (p < 0.05 for DIXON- and −8 ± 13% for CT-based AC. Significant systematic differences were observed for kinetic parameters derived from emission data obtained from PET/MR and PET-only imaging due to different standard AC methods employed. Therefore, a transfer of imaging protocols from PET-only to PET/MR systems is not straightforward without application of proper correction methods.Clinical Trial Registration:www.clinicaltrialsregister.eu, identifier 2013-001724-19

  14. Comparison of 18F-FDG PET/CT and PET/MRI in patients with multiple myeloma

    OpenAIRE

    Sachpekidis, Christos; Hillengass, Jens; Goldschmidt, Hartmut; Mosebach, Jennifer; Pan, Leyun; Schlemmer, Heinz-Peter; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2015-01-01

    PET/MRI represents a promising hybrid imaging modality with several potential clinical applications. Although PET/MRI seems highly attractive in the diagnostic approach of multiple myeloma (MM), its role has not yet been evaluated. The aims of this prospective study are to evaluate the feasibility of 18F-FDG PET/MRI in detection of MM lesions, and to investigate the reproducibility of bone marrow lesions detection and quantitative data of 18F-FDG uptake between the functional (PET) component ...

  15. Reproducibility of automated simplified voxel-based analysis of PET amyloid ligand [11C]PIB uptake using 30-min scanning data

    International Nuclear Information System (INIS)

    Aalto, Sargo; Scheinin, Noora M.; Naagren, Kjell; Rinne, Juha O.; Kemppainen, Nina M.; Kailajaervi, Marita; Leinonen, Mika; Scheinin, Mika

    2009-01-01

    Positron emission tomography (PET) with 11 C-labelled Pittsburgh compound B ([ 11 C]PIB) enables the quantitation of β-amyloid accumulation in the brain of patients with Alzheimer's disease (AD). Voxel-based image analysis techniques conducted in a standard brain space provide an objective, rapid and fully automated method to analyze [ 11 C]PIB PET data. The purpose of this study was to evaluate both region- and voxel-level reproducibility of automated and simplified [ 11 C]PIB quantitation when using only 30 min of imaging data. Six AD patients and four healthy controls were scanned twice with an average interval of 6 weeks. To evaluate the feasibility of short scanning (convenient for AD patients), [ 11 C]PIB uptake was quantitated using 30 min of imaging data (60 to 90 min after tracer injection) for region-to-cerebellum ratio calculations. To evaluate the reproducibility, a test-retest design was used to derive absolute variability (VAR) estimates and intraclass correlation coefficients at both region-of-interest (ROI) and voxel level. The reproducibility both at the region level (VAR 0.9-5.5%) and at the voxel level (VAR 4.2-6.4%) was good to excellent. Based on the variability estimates obtained, power calculations indicated that 90% power to obtain statistically significant difference can be achieved using a sample size of five subjects per group when a 15% change from baseline (increase or decrease) in [ 11 C]PIB accumulation in the frontal cortex is anticipated in one group compared to no change in another group. Our results showed that an automated analysis method based on an efficient scanning protocol provides reproducible results for [ 11 C]PIB uptake and appears suitable for PET studies aiming at the quantitation of amyloid accumulation in the brain of AD patients for the evaluation of progression and treatment effects. (orig.)

  16. Machine learning-based kinetic modeling: a robust and reproducible solution for quantitative analysis of dynamic PET data.

    Science.gov (United States)

    Pan, Leyun; Cheng, Caixia; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2017-05-07

    A variety of compartment models are used for the quantitative analysis of dynamic positron emission tomography (PET) data. Traditionally, these models use an iterative fitting (IF) method to find the least squares between the measured and calculated values over time, which may encounter some problems such as the overfitting of model parameters and a lack of reproducibility, especially when handling noisy data or error data. In this paper, a machine learning (ML) based kinetic modeling method is introduced, which can fully utilize a historical reference database to build a moderate kinetic model directly dealing with noisy data but not trying to smooth the noise in the image. Also, due to the database, the presented method is capable of automatically adjusting the models using a multi-thread grid parameter searching technique. Furthermore, a candidate competition concept is proposed to combine the advantages of the ML and IF modeling methods, which could find a balance between fitting to historical data and to the unseen target curve. The machine learning based method provides a robust and reproducible solution that is user-independent for VOI-based and pixel-wise quantitative analysis of dynamic PET data.

  17. Machine learning-based kinetic modeling: a robust and reproducible solution for quantitative analysis of dynamic PET data

    Science.gov (United States)

    Pan, Leyun; Cheng, Caixia; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2017-05-01

    A variety of compartment models are used for the quantitative analysis of dynamic positron emission tomography (PET) data. Traditionally, these models use an iterative fitting (IF) method to find the least squares between the measured and calculated values over time, which may encounter some problems such as the overfitting of model parameters and a lack of reproducibility, especially when handling noisy data or error data. In this paper, a machine learning (ML) based kinetic modeling method is introduced, which can fully utilize a historical reference database to build a moderate kinetic model directly dealing with noisy data but not trying to smooth the noise in the image. Also, due to the database, the presented method is capable of automatically adjusting the models using a multi-thread grid parameter searching technique. Furthermore, a candidate competition concept is proposed to combine the advantages of the ML and IF modeling methods, which could find a balance between fitting to historical data and to the unseen target curve. The machine learning based method provides a robust and reproducible solution that is user-independent for VOI-based and pixel-wise quantitative analysis of dynamic PET data.

  18. MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner.

    Science.gov (United States)

    Catana, Ciprian; Benner, Thomas; van der Kouwe, Andre; Byars, Larry; Hamm, Michael; Chonde, Daniel B; Michel, Christian J; El Fakhri, Georges; Schmand, Matthias; Sorensen, A Gregory

    2011-01-01

    Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MRI data can be used for motion tracking. In this work, a novel algorithm for data processing and rigid-body motion correction (MC) for the MRI-compatible BrainPET prototype scanner is described, and proof-of-principle phantom and human studies are presented. To account for motion, the PET prompt and random coincidences and sensitivity data for postnormalization were processed in the line-of-response (LOR) space according to the MRI-derived motion estimates. The processing time on the standard BrainPET workstation is approximately 16 s for each motion estimate. After rebinning in the sinogram space, the motion corrected data were summed, and the PET volume was reconstructed using the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed, and motion estimates were obtained using 2 high-temporal-resolution MRI-based motion-tracking techniques. After accounting for the misalignment between the 2 scanners, perfectly coregistered MRI and PET volumes were reproducibly obtained. The MRI output gates inserted into the PET list-mode allow the temporal correlation of the 2 datasets within 0.2 ms. The Hoffman phantom volume reconstructed by processing the PET data in the LOR space was similar to the one obtained by processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the procedure. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 s and 20 ms, respectively. Motion-deblurred PET images, with excellent delineation of specific brain structures, were obtained using these 2 MRI

  19. SU-F-I-31: Reproducibility of An Automatic Exposure Control Technique in the Low-Dose CT Scan of Cardiac PET/CT Exams

    Energy Technology Data Exchange (ETDEWEB)

    Park, M; Rosica, D; Agarwal, V; Di Carli, M; Dorbala, S [Brigham and Women’s Hospital and Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: Two separate low-dose CT scans are usually performed for attenuation correction of rest and stress N-13 ammonia PET/CT myocardial perfusion imaging (PET/CT). We utilize an automatic exposure control (AEC) technique to reduce CT radiation dose while maintaining perfusion image quality. Our goal is to assess the reproducibility of displayed CT dose index (CTDI) on same-day repeat CT scans (CT1 and CT2). Methods: Retrospectively, we reviewed CT images of PET/CT studies performed on the same day. Low-dose CT utilized AEC technique based on tube current modulation called Smart-mA. The scan parameters were 64 × 0.625mm collimation, 5mm slice thickness, 0.984 pitch, 1-sec rotation time, 120 kVp, and noise index 50 with a range of 10–200 mA. The scan length matched with PET field of view (FOV) with the heart near the middle of axial FOV. We identified the reference slice number (RS) for an anatomical landmark (carina) and used it to estimate axial shift between two CTs. For patient size, we measured an effective diameter on the reference slice. The effect of patient positioning to CTDI was evaluated using the table height. We calculated the absolute percent difference of the CTDI (%diff) for estimation of the reproducibility. Results: The study included 168 adults with an average body-mass index of 31.72 ± 9.10 (kg/m{sup 2}) and effective diameter was 32.72 ± 4.60 cm. The average CTDI was 1.95 ± 1.40 mGy for CT1 and 1.97 ± 1.42mGy for CT2. The mean %diff was 7.8 ± 6.8%. Linear regression analysis showed a significant correlation between the table height and %diff CTDI. (r=0.82, p<0.001) Conclusion: We have shown for the first time in human subjects, using two same-day CT images, that the AEC technique in low-dose CT is reproducible within 10% and significantly depends on the patient centering.

  20. MR-assisted PET Motion Correction for eurological Studies in an Integrated MR-PET Scanner

    Science.gov (United States)

    Catana, Ciprian; Benner, Thomas; van der Kouwe, Andre; Byars, Larry; Hamm, Michael; Chonde, Daniel B.; Michel, Christian J.; El Fakhri, Georges; Schmand, Matthias; Sorensen, A. Gregory

    2011-01-01

    Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MR data can be used for motion tracking. In this work, a novel data processing and rigid-body motion correction (MC) algorithm for the MR-compatible BrainPET prototype scanner is described and proof-of-principle phantom and human studies are presented. Methods To account for motion, the PET prompts and randoms coincidences as well as the sensitivity data are processed in the line or response (LOR) space according to the MR-derived motion estimates. After sinogram space rebinning, the corrected data are summed and the motion corrected PET volume is reconstructed from these sinograms and the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed and motion estimates were obtained using two high temporal resolution MR-based motion tracking techniques. Results After accounting for the physical mismatch between the two scanners, perfectly co-registered MR and PET volumes are reproducibly obtained. The MR output gates inserted in to the PET list-mode allow the temporal correlation of the two data sets within 0.2 s. The Hoffman phantom volume reconstructed processing the PET data in the LOR space was similar to the one obtained processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the novel MC algorithm. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 seconds and 20 ms, respectively. Substantially improved PET images with excellent delineation of specific brain structures were obtained after applying the MC using these MR-based estimates. Conclusion A novel MR-based MC

  1. Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System

    DEFF Research Database (Denmark)

    Lassen, Martin L; Muzik, Otto; Beyer, Thomas

    2017-01-01

    The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET)-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic paramet...

  2. Quantitative and Visual Assessments toward Potential Sub-mSv or Ultrafast FDG PET Using High-Sensitivity TOF PET in PET/MRI.

    Science.gov (United States)

    Behr, Spencer C; Bahroos, Emma; Hawkins, Randall A; Nardo, Lorenzo; Ravanfar, Vahid; Capbarat, Emily V; Seo, Youngho

    2018-06-01

    Newer high-performance time-of-flight (TOF) positron emission tomography (PET) systems have the capability to preserve diagnostic image quality with low count density, while maintaining a high raw photon detection sensitivity that would allow for a reduction in injected dose or rapid data acquisition. To assess this, we performed quantitative and visual assessments of the PET images acquired using a highly sensitive (23.3 cps/kBq) large field of view (25-cm axial) silicon photomultiplier (SiPM)-based TOF PET (400-ps timing resolution) integrated with 3 T-MRI in comparison to PET images acquired on non-TOF PET/x-ray computed tomography (CT) systems. Whole-body 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) PET/CT was acquired for 15 patients followed by whole body PET/magnetic resonance imaging (MRI) with an average injected dose of 325 ± 84 MBq. The PET list mode data from PET/MRI were reconstructed using full datasets (4 min/bed) and reduced datasets (2, 1, 0.5, and 0.25 min/bed). Qualitative assessment between PET/CT and PET/MR images were made. A Likert-type scale between 1 and 5, 1 for non-diagnostic, 3 equivalent to PET/CT, and 5 superior quality, was used. Maximum and mean standardized uptake values (SUV max and SUV mean ) of normal tissues and lesions detected were measured and compared. Mean visual assessment scores were 3.54 ± 0.32, 3.62 ± 0.38, and 3.69 ± 0.35 for the brain and 3.05 ± 0.49, 3.71 ± 0.45, and 4.14 ± 0.44 for the whole-body maximum intensity projections (MIPs) for 1, 2, and 4 min/bed PET/MR images, respectively. The SUV mean values for normal tissues were lower and statistically significant for images acquired at 4, 2, 1, 0.5, and 0.25 min/bed on the PET/MR, with values of - 18 ± 28 % (p PET/MR datasets. High-sensitivity TOF PET showed comparable but still better visual image quality even at a much reduced activity in comparison to lower-sensitivity non-TOF PET. Our data translates to a seven times

  3. Test-retest reproducibility of dopamine D{sub 2/3} receptor binding in human brain measured by PET with [{sup 11}C]MNPA and [{sup 11}C]raclopride

    Energy Technology Data Exchange (ETDEWEB)

    Kodaka, Fumitoshi [National Institute of Radiological Sciences, Molecular Neuroimaging Program, Molecular Imaging Center, Chiba (Japan); Jikei University School of Medicine, Department of Psychiatry, Tokyo (Japan); Ito, Hiroshi [National Institute of Radiological Sciences, Molecular Neuroimaging Program, Molecular Imaging Center, Chiba (Japan); National Institute of Radiological Sciences, Biophysics Program, Molecular Imaging Center, Chiba (Japan); Kimura, Yasuyuki; Fujie, Saori; Takano, Harumasa; Fujiwara, Hironobu; Sasaki, Takeshi; Suhara, Tetsuya [National Institute of Radiological Sciences, Molecular Neuroimaging Program, Molecular Imaging Center, Chiba (Japan); Nakayama, Kazuhiko [Jikei University School of Medicine, Department of Psychiatry, Tokyo (Japan); Halldin, Christer; Farde, Lars [Karolinska Institutet, Department of Clinical Neuroscience, Stockholm (Sweden)

    2013-04-15

    Dopamine D{sub 2/3} receptors (D{sub 2/3}Rs) have two affinity states for endogenous dopamine, referred to as high-affinity state (D{sub 2/3} {sup HIGH}), which has a high affinity for endogenous dopamine, and low-affinity state (D{sub 2/3} {sup LOW}). The density of D{sub 2/3} {sup HIGH} can be measured with (R)-2-{sup 11}CH{sub 3}O-N-n-propylnorapomorphine ([{sup 11}C]MNPA), while total density of D{sub 2/3} {sup HIGH} and D{sub 2/3} {sup LOW} (D{sub 2/3}Rs) can be measured with [{sup 11}C]raclopride using positron emission tomography (PET). Thus, the ratio of the binding potential (BP) of [{sup 11}C]MNPA to that of [{sup 11}C]raclopride ([{sup 11}C]MNPA/[{sup 11}C]raclopride) may reflect the proportion of the density of D{sub 2/3} {sup HIGH} to that of D{sub 2/3}Rs. In the caudate and putamen, [{sup 11}C]MNPA/[{sup 11}C]raclopride reflects the proportion of the density of D{sub 2} {sup HIGH} to that of D{sub 2}Rs. To evaluate the reliability of the PET paradigm with [{sup 11}C]MNPA and [{sup 11}C]raclopride, we investigated the test-retest reproducibility of non-displaceable BP (BP{sub ND}) measured with [{sup 11}C]MNPA and of [{sup 11}C]MNPA/[{sup 11}C]raclopride in healthy humans. Eleven healthy male volunteers underwent two sets of PET studies on separate days that each included [{sup 11}C]MNPA and [{sup 11}C]raclopride scans. BP{sub ND} values in the caudate and putamen were calculated. Test-retest reproducibility of BP{sub ND} of [{sup 11}C]MNPA and [{sup 11}C]MNPA/[{sup 11}C]raclopride was assessed by intra-subject variability (absolute variability) and test-retest reliability (intraclass correlation coefficient: ICC). The absolute variability of [{sup 11}C]MNPA BP{sub ND} was 5.30 {+-} 3.96 % and 12.3 {+-} 7.95 % and the ICC values of [{sup 11}C]MNPA BP{sub ND} were 0.72 and 0.82 in the caudate and putamen, respectively. The absolute variability of [{sup 11}C]MNPA/[{sup 11}C]raclopride was 6.11 {+-} 3.68 % and 11.60 {+-} 5.70 % and the ICC values of [{sup

  4. Tumor volume in subcutaneous mouse xenografts measured by microCT is more accurate and reproducible than determined by 18F-FDG-microPET or external caliper

    DEFF Research Database (Denmark)

    Jensen, Mette Munk; Jørgensen, Jesper Tranekjaer; Binderup, Tina

    2008-01-01

    BACKGROUND: In animal studies tumor size is used to assess responses to anticancer therapy. Current standard for volumetric measurement of xenografted tumors is by external caliper, a method often affected by error. The aim of the present study was to evaluate if microCT gives more accurate...... (n = 20) was determined in vivo by external caliper, microCT and 18F-FDG-PET and subsequently reference volume was determined ex vivo. Intra-observer reproducibility of the microCT and caliper methods were determined by acquiring 10 repeated volume measurements. Volumes of a group of tumors (n = 10......) were determined independently by two observers to assess inter-observer variation. RESULTS: Tumor volume measured by microCT, PET and caliper all correlated with reference volume. No significant bias of microCT measurements compared with the reference was found, whereas both PET and caliper had...

  5. Comparison of lesion detection and quantitation of tracer uptake between PET from a simultaneously acquiring whole-body PET/MR hybrid scanner and PET from PET/CT

    International Nuclear Information System (INIS)

    Wiesmueller, Marco; Schmidt, Daniela; Beck, Michael; Kuwert, Torsten; Gall, Carl C. von; Quick, Harald H.; Navalpakkam, Bharath; Lell, Michael M.; Uder, Michael; Ritt, Philipp

    2013-01-01

    PET/MR hybrid scanners have recently been introduced, but not yet validated. The aim of this study was to compare the PET components of a PET/CT hybrid system and of a simultaneous whole-body PET/MR hybrid system with regard to reproducibility of lesion detection and quantitation of tracer uptake. A total of 46 patients underwent a whole-body PET/CT scan 1 h after injection and an average of 88 min later a second scan using a hybrid PET/MR system. The radioactive tracers used were 18 F-deoxyglucose (FDG), 18 F-ethylcholine (FEC) and 68 Ga-DOTATATE (Ga-DOTATATE). The PET images from PET/CT (PET CT ) and from PET/MR (PET MR ) were analysed for tracer-positive lesions. Regional tracer uptake in these foci was quantified using volumes of interest, and maximal and average standardized uptake values (SUV max and SUV avg , respectively) were calculated. Of the 46 patients, 43 were eligible for comparison and statistical analysis. All lesions except one identified by PET CT were identified by PET MR (99.2 %). In 38 patients (88.4 %), the same number of foci were identified by PET CT and by PET MR . In four patients, more lesions were identified by PET MR than by PET CT , in one patient PET CT revealed an additional focus compared to PET MR . The mean SUV max and SUV avg of all lesions determined by PET MR were by 21 % and 11 % lower, respectively, than the values determined by PET CT (p CT and PET MR were minor, but statistically significant. Nevertheless, a more detailed study of the quantitative accuracy of PET MR and the factors governing it is needed to ultimately assess its accuracy in measuring tissue tracer concentrations. (orig.)

  6. Assessment of endothelial function and myocardial flow reserve using 15O-water PET without attenuation correction

    International Nuclear Information System (INIS)

    Tuffier, Stephane; Joubert, Michael; Bailliez, Alban; Legallois, Damien; Belin, Annette; Redonnet, Michel; Agostini, Denis; Manrique, Alain

    2016-01-01

    Myocardial blood flow (MBF) measurement using positron emission tomography (PET) from the washout rate of 15 O-water is theoretically independent of tissue attenuation. The aim of this study was to evaluate the impact of not using attenuation correction in the assessment of coronary endothelial function and myocardial flow reserve (MFR) using 15 O-water PET. We retrospectively processed 70 consecutive 15 O-water PET examinations obtained at rest and during cold pressor testing (CPT) in patients with dilated cardiomyopathy (n = 58), or at rest and during adenosine infusion in heart transplant recipients (n = 12). Data were reconstructed with attenuation correction (AC) and without attenuation correction (NAC) using filtered backprojection, and MBF was quantified using a single compartmental model. The agreement between AC and NAC data was assessed using Lin's concordance correlation coefficient followed by Bland-Altman plot analysis. Regarding endothelial function, NAC PET showed poor reproducibility and poor agreement with AC PET data. Conversely, NAC PET demonstrated high reproducibility and a strong agreement with AC PET for the assessment of MFR. Non-attenuation-corrected 15 O-water PET provided an accurate measurement of MFR compared to attenuation-corrected PET. However, non-attenuation-corrected PET data were less effective for the assessment of endothelial function using CPT in this population. (orig.)

  7. Reproducibility of 'Intelligent' Contouring of Gross Tumor Volume in Non-Small-Cell Lung Cancer on PET/CT Images Using a Standardized Visual Method

    International Nuclear Information System (INIS)

    Bayne, Michael; Hicks, Rodney J.; Everitt, Sarah; Fimmell, Natalie

    2010-01-01

    Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly used for delineating gross tumor volume (GTV) in non-small-cell lung cancer (NSCLC). The methodology for contouring tumor margins remains controversial. We developed a rigorous visual protocol for contouring GTV that uses all available clinical information and studied its reproducibility in patients from a prospective PET/CT planning trial. Methods and Materials: Planning PET/CT scans from 6 consecutive patients were selected. Six 'observers' (two radiation oncologists, two nuclear medicine physicians, and two radiologists) contoured GTVs for each patient using a predefined protocol and subsequently recontoured 2 patients. For the estimated GTVs and axial distances, least-squares means for each observer and for each case were calculated and compared, using the F test and pairwise t-tests. In five cases, tumor margins were also autocontoured using standardized uptake value (SUV) cutoffs of 2.5 and 3.5 and 40% SUV max . Results: The magnitude of variation between observers was small relative to the mean (coefficient of variation [CV] = 3%), and the total variation (intraclass correlation coefficient [ICC] = 3%). For estimation of superior/inferior (SI), left/right (LR), and anterior/posterior (AP) borders of the GTV, differences between observers were also small (AP, CV = 2%, ICC = 0.4%; LR, CV = 6%, ICC = 2%; SI, CV 4%, ICC = 2%). GTVs autocontoured generated using SUV 2.5, 3.5, and 40% SUV max differed widely in each case. An SUV contour of 2.5 was most closely correlated with the mean GTV defined by the human observers. Conclusions: Observer variation contributed little to total variation in the GTV and axial distances. A visual contouring protocol gave reproducible results for contouring GTV in NSCLC.

  8. High value carbon materials from PET recycling

    International Nuclear Information System (INIS)

    Parra, J.B.; Ania, C.O.; Arenillas, A.; Rubiera, F.; Pis, J.J.

    2004-01-01

    Poly(ethylene) terephthalate (PET), has become one of the major post-consumer plastic waste. In this work special attention was paid to minimising PET residues and to obtain a high value carbon material. Pyrolysis and subsequent activation of PET from post-consumer soft-drink bottles was performed. Activation was carried out at 925 deg. C under CO 2 atmosphere to different burn-off degrees. Textural characterisation of the samples was carried out by performing N 2 adsorption isotherms at -196 deg. C. The obtained carbons materials were mainly microporous, presenting low meso and macroporosity, and apparent BET surface areas of upto 2500 m 2 g -1 . The capacity of these materials for phenol adsorption and PAHs removal from aqueous solutions was measured and compared with that attained with commercial active carbons. Preliminary tests also showed high hydrogen uptake values, as good as the results obtained with high-tech carbon materials

  9. Myocardial blood flow quantification by Rb-82 cardiac PET/CT: A detailed reproducibility study between two semi-automatic analysis programs.

    Science.gov (United States)

    Dunet, Vincent; Klein, Ran; Allenbach, Gilles; Renaud, Jennifer; deKemp, Robert A; Prior, John O

    2016-06-01

    Several analysis software packages for myocardial blood flow (MBF) quantification from cardiac PET studies exist, but they have not been compared using concordance analysis, which can characterize precision and bias separately. Reproducible measurements are needed for quantification to fully develop its clinical potential. Fifty-one patients underwent dynamic Rb-82 PET at rest and during adenosine stress. Data were processed with PMOD and FlowQuant (Lortie model). MBF and myocardial flow reserve (MFR) polar maps were quantified and analyzed using a 17-segment model. Comparisons used Pearson's correlation ρ (measuring precision), Bland and Altman limit-of-agreement and Lin's concordance correlation ρc = ρ·C b (C b measuring systematic bias). Lin's concordance and Pearson's correlation values were very similar, suggesting no systematic bias between software packages with an excellent precision ρ for MBF (ρ = 0.97, ρc = 0.96, C b = 0.99) and good precision for MFR (ρ = 0.83, ρc = 0.76, C b = 0.92). On a per-segment basis, no mean bias was observed on Bland-Altman plots, although PMOD provided slightly higher values than FlowQuant at higher MBF and MFR values (P < .0001). Concordance between software packages was excellent for MBF and MFR, despite higher values by PMOD at higher MBF values. Both software packages can be used interchangeably for quantification in daily practice of Rb-82 cardiac PET.

  10. High value carbon materials from PET recycling

    Energy Technology Data Exchange (ETDEWEB)

    Parra, J.B.; Ania, C.O.; Arenillas, A.; Rubiera, F.; Pis, J.J

    2004-11-15

    Poly(ethylene) terephthalate (PET), has become one of the major post-consumer plastic waste. In this work special attention was paid to minimising PET residues and to obtain a high value carbon material. Pyrolysis and subsequent activation of PET from post-consumer soft-drink bottles was performed. Activation was carried out at 925 deg. C under CO{sub 2} atmosphere to different burn-off degrees. Textural characterisation of the samples was carried out by performing N{sub 2} adsorption isotherms at -196 deg. C. The obtained carbons materials were mainly microporous, presenting low meso and macroporosity, and apparent BET surface areas of upto 2500 m{sup 2} g{sup -1}. The capacity of these materials for phenol adsorption and PAHs removal from aqueous solutions was measured and compared with that attained with commercial active carbons. Preliminary tests also showed high hydrogen uptake values, as good as the results obtained with high-tech carbon materials.

  11. [¹⁸F]-fluorodeoxyglucose PET imaging of atherosclerosis

    DEFF Research Database (Denmark)

    Blomberg, Björn Alexander; Høilund-Carlsen, Poul Flemming

    2015-01-01

    [(18)F]-fluorodeoxyglucose PET ((18)FDG PET) imaging has emerged as a promising tool for assessment of atherosclerosis. By targeting atherosclerotic plaque glycolysis, a marker for plaque inflammation and hypoxia, (18)FDG PET can assess plaque vulnerability and potentially predict risk...... of atherosclerosis-related disease, such as stroke and myocardial infarction. With excellent reproducibility, (18)FDG PET can be a surrogate end point in clinical drug trials, improving trial efficiency. This article summarizes key findings in the literature, discusses limitations of (18)FDG PET imaging...

  12. Transparent, flexible surface enhanced Raman scattering substrates based on Ag-coated structured PET (polyethylene terephthalate) for in-situ detection

    International Nuclear Information System (INIS)

    Zuo, Zewen; Zhu, Kai; Gu, Chuan; Wen, Yibing; Cui, Guanglei; Qu, Jun

    2016-01-01

    Highlights: • Transparent, flexible SERS substrates were prepared using techniques compatible with well-established silicon device technologies. • The SERS substrates exhibit high sensitivity and good reproducibility. • The high performance is related with the quasi-three-dimensional structure of the PET. • In-situ detection of analyte on irregular objects was achieved by this SERS substrate. - Abstract: Transparent, flexible surface-enhanced Raman scattering (SERS) substrates were fabricated by metalization of structured polyethylene terephthalate (PET) sheets. The resultant Ag-coated structured PET SERS substrates were revealed to be highly sensitive with good reproducibility and stability, an enhancement factor of 3 × 10 6 was acquired, which can be attributed mainly to the presence of plentiful multiple-type hot spots within the quasi-three-dimensional surface of the structured PET obtained by oxygen plasma etching. In addition, detections of model molecules on fruit skin were also carried out, demonstrating the great potential of the Ag-coated structured PET in in-situ detection of analyte on irregular objects. Importantly, the technique used for the preparation of such substrate is completely compatible with well-established silicon device technologies, and large-area fabrication with low cost can be readily realized.

  13. Transparent, flexible surface enhanced Raman scattering substrates based on Ag-coated structured PET (polyethylene terephthalate) for in-situ detection

    Energy Technology Data Exchange (ETDEWEB)

    Zuo, Zewen, E-mail: zuozewen@mail.ahnu.edu.cn; Zhu, Kai; Gu, Chuan; Wen, Yibing; Cui, Guanglei; Qu, Jun

    2016-08-30

    Highlights: • Transparent, flexible SERS substrates were prepared using techniques compatible with well-established silicon device technologies. • The SERS substrates exhibit high sensitivity and good reproducibility. • The high performance is related with the quasi-three-dimensional structure of the PET. • In-situ detection of analyte on irregular objects was achieved by this SERS substrate. - Abstract: Transparent, flexible surface-enhanced Raman scattering (SERS) substrates were fabricated by metalization of structured polyethylene terephthalate (PET) sheets. The resultant Ag-coated structured PET SERS substrates were revealed to be highly sensitive with good reproducibility and stability, an enhancement factor of 3 × 10{sup 6} was acquired, which can be attributed mainly to the presence of plentiful multiple-type hot spots within the quasi-three-dimensional surface of the structured PET obtained by oxygen plasma etching. In addition, detections of model molecules on fruit skin were also carried out, demonstrating the great potential of the Ag-coated structured PET in in-situ detection of analyte on irregular objects. Importantly, the technique used for the preparation of such substrate is completely compatible with well-established silicon device technologies, and large-area fabrication with low cost can be readily realized.

  14. Breast cancer detection using high-resolution breast PET compared to whole-body PET or PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Kalinyak, Judith E. [Naviscan Inc., San Diego, CA (United States); Berg, Wendie A. [University of Pittsburgh School of Medicine, Magee-Womens Hospital, Pittsburgh, PA (United States); Schilling, Kathy [Boca Raton Regional Hospital, Boca Raton, FL (United States); Madsen, Kathleen S. [Certus International, Inc., St. Louis, MO (United States); Narayanan, Deepa [Naviscan Inc., San Diego, CA (United States); National Cancer Institute, Bethesda, MD (United States); Tartar, Marie [Scripps Clinic, Scripps Green Hospital, La Jolla, CA (United States)

    2014-02-15

    To compare the performance characteristics of positron emission mammography (PEM) with those of whole-body PET (WBPET) and PET/CT in women with newly diagnosed breast cancer. A total of 178 women consented to PEM for presurgical planning in an IRB-approved protocol and also underwent either WBPET (n = 69) or PET/CT (n = 109) imaging, as per usual care at three centers. Tumor detection sensitivity, positive predictive values, and {sup 18}F-fluorodeoxyglucose (FDG) uptake were compared between the modalities. The effects of tumor size, type, and grade on detection were examined. The chi-squared or Fisher's exact tests were used to compare distributions between groups, and McNemar's test was used to compare distributions for paired data within subject groups, i.e. PEM versus WBPET or PEM versus PET/CT. The mean age of the women was 59 ± 12 years (median 60 years, range 26-89 years), with a mean invasive index tumor size of 1.6 ± 0.8 cm (median 1.5 cm, range 0.5-4.0 cm). PEM detected more index tumors (61/66, 92 %) than WBPET (37/66, 56 %; p < 0.001) or PET/CT (95/109, 87 % vs. 104/109, 95 % for PEM; p < 0.029). Sensitivity for the detection of additional ipsilateral malignancies was also greater with PEM (7/15, 47 %) than with WBPET (1/15, 6.7 %; p = 0.014) or PET/CT (3/23, 13 % vs. 13/23, 57 % for PEM; p = 0.003). Index tumor detection decreased with decreasing invasive tumor size for both WBPET (p = 0.002) and PET/CT (p < 0.001); PEM was not significantly affected (p = 0.20). FDG uptake, quantified in terms of maximum PEM uptake value, was lowest in ductal carcinoma in situ (median 1.5, range 0.7-3.0) and invasive lobular carcinoma (median 1.5, range 0.7-3.4), and highest in grade III invasive ductal carcinoma (median 3.1, range 1.4-12.9). PEM was more sensitive than either WBPET or PET/CT in showing index and additional ipsilateral breast tumors and remained highly sensitive for tumors smaller than 1 cm. (orig.)

  15. Assessment of endothelial function and myocardial flow reserve using {sup 15}O-water PET without attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Tuffier, Stephane; Joubert, Michael; Bailliez, Alban [EA 4650, Normandie Universite, Caen (France); Legallois, Damien [EA 4650, Normandie Universite, Caen (France); Caen University Hospital, Department of Cardiology, Caen (France); Belin, Annette [Caen University Hospital, Department of Cardiac Surgery, Caen (France); Redonnet, Michel [Rouen University Hospital, Department of Cardiac Surgery, Rouen (France); Agostini, Denis [EA 4650, Normandie Universite, Caen (France); Caen University Hospital, Department of Nuclear Medicine, Caen (France); Manrique, Alain [EA 4650, Normandie Universite, Caen (France); Caen University Hospital, Department of Nuclear Medicine, Caen (France); Cyceron PET Centre, Caen (France)

    2016-02-15

    Myocardial blood flow (MBF) measurement using positron emission tomography (PET) from the washout rate of {sup 15}O-water is theoretically independent of tissue attenuation. The aim of this study was to evaluate the impact of not using attenuation correction in the assessment of coronary endothelial function and myocardial flow reserve (MFR) using {sup 15}O-water PET. We retrospectively processed 70 consecutive {sup 15}O-water PET examinations obtained at rest and during cold pressor testing (CPT) in patients with dilated cardiomyopathy (n = 58), or at rest and during adenosine infusion in heart transplant recipients (n = 12). Data were reconstructed with attenuation correction (AC) and without attenuation correction (NAC) using filtered backprojection, and MBF was quantified using a single compartmental model. The agreement between AC and NAC data was assessed using Lin's concordance correlation coefficient followed by Bland-Altman plot analysis. Regarding endothelial function, NAC PET showed poor reproducibility and poor agreement with AC PET data. Conversely, NAC PET demonstrated high reproducibility and a strong agreement with AC PET for the assessment of MFR. Non-attenuation-corrected {sup 15}O-water PET provided an accurate measurement of MFR compared to attenuation-corrected PET. However, non-attenuation-corrected PET data were less effective for the assessment of endothelial function using CPT in this population. (orig.)

  16. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  17. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    Science.gov (United States)

    Wu, T.-H.; Liang, C.-H.; Wu, J.-K.; Lien, C.-Y.; Yang, B.-H.; Huang, Y.-H.; Lee, J. J. S.

    2009-07-01

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of 18F-fluorodeoxyglucose (18F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT may have a

  18. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    International Nuclear Information System (INIS)

    Wu, T-H; Liang, C-H; Wu, J-K; Lien, C-Y; Yang, B-H; Lee, J J S; Huang, Y-H

    2009-01-01

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of 18 F-fluorodeoxyglucose ( 18 F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT may have a

  19. Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging

    International Nuclear Information System (INIS)

    Aschoff, Philip; Plathow, Christian; Lichy, Matthias P.; Claussen, Claus D.; Pfannenberg, Christina; Beyer, Thomas; Erb, Gunter; Oeksuez, Mehmet Oe.

    2012-01-01

    State-of-the-art positron emission tomography/computed tomography (PET/CT) systems incorporate multislice CT technology, thus facilitating the acquisition of multiphase, contrast-enhanced CT data as part of integrated PET/CT imaging protocols. We assess the influence of a highly concentrated iodinated contrast medium (CM) on quantification and image quality following CT-based attenuation correction (CT-AC) in PET/CT. Twenty-eight patients with suspected malignant liver lesions were enrolled prospectively. PET/CT was performed 60 min after injection of 400 MBq of 18 F-fluorodeoxyglucose (FDG) and following the biphasic administration of an intravenous CM (400 mg iodine/ml, Iomeron 400). PET images were reconstructed with CT-AC using any of four acquired CT image sets: non-enhanced, pre-contrast (n-PET), arterial phase (art-PET), portal venous phase (pv-PET) and late phase (late-PET). Normal tissue activity and liver lesions were assessed visually and quantitatively on each PET/CT image set. Visual assessment of PET following CT-AC revealed no noticeable difference in image appearance or quality when using any of the four CT data sets for CT-AC. A total of 44 PET-positive liver lesions was identified in 21 of 28 patients. There were no false-negative or false-positive lesions on PET. Mean standardized uptake values (SUV) in 36 evaluable lesions were: 5.5 (n-PET), 5.8 (art-PET), 5.8 (pv-PET) and 5.8 (late-PET), with the highest mean increase in mean SUV of 6%. Mean SUV changes in liver background increased by up to 10% from n-PET to pv-PET. Multiphase CT data acquired with the use of highly concentrated CM can be used for qualitative assessment of liver lesions in torso FDG PET/CT. The influence on quantification of FDG uptake is small and negligible for most clinical applications. (orig.)

  20. High-Resolution PET Detector. Final report

    International Nuclear Information System (INIS)

    Karp, Joel

    2014-01-01

    The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface

  1. High Efficiency, Low Cost Scintillators for PET

    International Nuclear Information System (INIS)

    Kanai Shah

    2007-01-01

    Inorganic scintillation detectors coupled to PMTs are an important element of medical imaging applications such as positron emission tomography (PET). Performance as well as cost of these systems is limited by the properties of the scintillation detectors available at present. The Phase I project was aimed at demonstrating the feasibility of producing high performance scintillators using a low cost fabrication approach. Samples of these scintillators were produced and their performance was evaluated. Overall, the Phase I effort was very successful. The Phase II project will be aimed at advancing the new scintillation technology for PET. Large samples of the new scintillators will be produced and their performance will be evaluated. PET modules based on the new scintillators will also be built and characterized

  2. Highly reproducible polyol synthesis for silver nanocubes

    Science.gov (United States)

    Han, Hye Ji; Yu, Taekyung; Kim, Woo-Sik; Im, Sang Hyuk

    2017-07-01

    We could synthesize the Ag nanocubes highly reproducibly by conducting the polyol synthesis using HCl etchant in dark condition because the photodecomposition/photoreduction of AgCl nanoparticles formed at initial reaction stage were greatly depressed and consequently the selective self-nucleation of Ag single crystals and their selective growth reaction could be promoted. Whereas the reproducibility of the formation of Ag nanocubes were very poor when we synthesize the Ag nanocubes in light condition due to the photoreduction of AgCl to Ag.

  3. Simultaneous whole-body {sup 18}F-PSMA-1007-PET/MRI with integrated high-resolution multiparametric imaging of the prostatic fossa for comprehensive oncological staging of patients with prostate cancer. A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, Martin T.; Bonekamp, David; Schlemmer, Heinz-Peter [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Kesch, Claudia; Radtke, Jan P.; Hohenfellner, Markus [University Hospital Heidelberg, Department of Urology, Heidelberg (Germany); Cardinale, Jens; Kopka, Klaus [German Cancer Research Center, Division of Radiopharmaceutical Chemistry, Heidelberg (Germany); Flechsig, Paul; Kratochwil, Clemens; Giesel, Frederik [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Floca, Ralf [German Cancer Research Center, Medical Image Computing Group, Heidelberg (Germany); Eiber, Matthias [Technical University Hospital Munich, Department of Nuclear Medicine, Munich (Germany); Stenzinger, Albrecht [University Hospital Heidelberg, Institute of Pathology, Heidelberg (Germany); Haberkorn, Uwe [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); German Cancer Research Center, Clinical Cooperation Unit Nuclear Medicine, Heidelberg (Germany)

    2018-03-15

    The aim of the present study was to explore the clinical feasibility and reproducibility of a comprehensive whole-body {sup 18}F-PSMA-1007-PET/MRI protocol for imaging prostate cancer (PC) patients. Eight patients with high-risk biopsy-proven PC underwent a whole-body PET/MRI (3 h p.i.) including a multi-parametric prostate MRI after {sup 18}F-PSMA-1007-PET/CT (1 h p.i.) which served as reference. Seven patients presented with non-treated PC, whereas one patient presented with biochemical recurrence. SUV{sub mean}-quantification was performed using a 3D-isocontour volume-of-interest. Imaging data was consulted for TNM-staging and compared with histopathology. PC was confirmed in 4/7 patients additionally by histopathology after surgery. PET-artifacts, co-registration of pelvic PET/MRI and MRI-data were assessed (PI-RADS 2.0). The examinations were well accepted by patients and comprised 1 h. SUV{sub mean}-values between PET/CT (1 h p.i.) and PET/MRI (3 h p.i.) were significantly correlated (p < 0.0001, respectively) and similar to literature of {sup 18}F-PSMA-1007-PET/CT 1 h vs 3 h p.i. The dominant intraprostatic lesion could be detected in all seven patients in both PET and MRI. T2c, T3a, T3b and T4 features were detected complimentarily by PET and MRI in five patients. PET/MRI demonstrated moderate photopenic PET-artifacts surrounding liver and kidneys representing high-contrast areas, no PET-artifacts were observed for PET/CT. Simultaneous PET-readout during prostate MRI achieved optimal co-registration results. The presented {sup 18}F-PSMA-1007-PET/MRI protocol combines efficient whole-body assessment with high-resolution co-registered PET/MRI of the prostatic fossa for comprehensive oncological staging of patients with PC. (orig.)

  4. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters.

    Science.gov (United States)

    Mhlanga, Joyce C; Carrino, John A; Lodge, Martin; Wang, Hao; Wahl, Richard L

    2014-12-01

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with (18)F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological (18)F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p = 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted.

  5. PetIGA: A framework for high-performance isogeometric analysis

    KAUST Repository

    Dalcin, Lisandro; Collier, N.; Vignal, Philippe; Cortes, Adriano Mauricio; Calo, Victor M.

    2016-01-01

    We present PetIGA, a code framework to approximate the solution of partial differential equations using isogeometric analysis. PetIGA can be used to assemble matrices and vectors which come from a Galerkin weak form, discretized with Non-Uniform Rational B-spline basis functions. We base our framework on PETSc, a high-performance library for the scalable solution of partial differential equations, which simplifies the development of large-scale scientific codes, provides a rich environment for prototyping, and separates parallelism from algorithm choice. We describe the implementation of PetIGA, and exemplify its use by solving a model nonlinear problem. To illustrate the robustness and flexibility of PetIGA, we solve some challenging nonlinear partial differential equations that include problems in both solid and fluid mechanics. We show strong scaling results on up to 40964096 cores, which confirm the suitability of PetIGA for large scale simulations.

  6. PetIGA: A framework for high-performance isogeometric analysis

    KAUST Repository

    Dalcin, L.

    2016-05-25

    We present PetIGA, a code framework to approximate the solution of partial differential equations using isogeometric analysis. PetIGA can be used to assemble matrices and vectors which come from a Galerkin weak form, discretized with Non-Uniform Rational B-spline basis functions. We base our framework on PETSc, a high-performance library for the scalable solution of partial differential equations, which simplifies the development of large-scale scientific codes, provides a rich environment for prototyping, and separates parallelism from algorithm choice. We describe the implementation of PetIGA, and exemplify its use by solving a model nonlinear problem. To illustrate the robustness and flexibility of PetIGA, we solve some challenging nonlinear partial differential equations that include problems in both solid and fluid mechanics. We show strong scaling results on up to 40964096 cores, which confirm the suitability of PetIGA for large scale simulations.

  7. NiftyPET: a High-throughput Software Platform for High Quantitative Accuracy and Precision PET Imaging and Analysis.

    Science.gov (United States)

    Markiewicz, Pawel J; Ehrhardt, Matthias J; Erlandsson, Kjell; Noonan, Philip J; Barnes, Anna; Schott, Jonathan M; Atkinson, David; Arridge, Simon R; Hutton, Brian F; Ourselin, Sebastien

    2018-01-01

    We present a standalone, scalable and high-throughput software platform for PET image reconstruction and analysis. We focus on high fidelity modelling of the acquisition processes to provide high accuracy and precision quantitative imaging, especially for large axial field of view scanners. All the core routines are implemented using parallel computing available from within the Python package NiftyPET, enabling easy access, manipulation and visualisation of data at any processing stage. The pipeline of the platform starts from MR and raw PET input data and is divided into the following processing stages: (1) list-mode data processing; (2) accurate attenuation coefficient map generation; (3) detector normalisation; (4) exact forward and back projection between sinogram and image space; (5) estimation of reduced-variance random events; (6) high accuracy fully 3D estimation of scatter events; (7) voxel-based partial volume correction; (8) region- and voxel-level image analysis. We demonstrate the advantages of this platform using an amyloid brain scan where all the processing is executed from a single and uniform computational environment in Python. The high accuracy acquisition modelling is achieved through span-1 (no axial compression) ray tracing for true, random and scatter events. Furthermore, the platform offers uncertainty estimation of any image derived statistic to facilitate robust tracking of subtle physiological changes in longitudinal studies. The platform also supports the development of new reconstruction and analysis algorithms through restricting the axial field of view to any set of rings covering a region of interest and thus performing fully 3D reconstruction and corrections using real data significantly faster. All the software is available as open source with the accompanying wiki-page and test data.

  8. New perspective in high tech radiotherapy planning using PET/CT images (Radiation oncologist's view on PET/CT usage)

    International Nuclear Information System (INIS)

    Hadjieva, T.; Bildirev, N.; Koleva, I.; Zahariev, Z.; Vasileva, V.; Encheva, E.; Sultanov, B.

    2010-01-01

    Biological images provided by 18F-FDG PET in combination with structural X ray picture currently offer the most accurate available information on tumour staging, curative antitumour effect for prognosis, impairment of organ function after treatment, as well as primary tumour detection in unknown primary metastatic disease. The authors as radiation oncologists critically have analyzed numerous clinical trials and two guidelines to prove PET/ CT benefit in radiotherapy practice. At present they found lack of scientific evidence to confirm that patient outcomes are superior as a result of the use of PET in RT planning. PET/CT offers a best image for tumour delineation only in some cases of lung cancer, mediastinal lymph nodes and malignant lymphomas. 11C methionin PET adds additional information on postoperative MRI image for brain tumours. Inflammation as postradiation phenomenon, as well as physiological organ movements leads to false-positive PET signal. High tech radiotherapy methods require delineation on precise images given after multidisciplinary team expertise - a practice that is possible only in clinical trials, These unsolved problems have raised many ethical challenges in medical, scientific and social aspect, if wide and routine use of FDG-PET u PET/CT is advocated. (authors)

  9. Poster - 01: LabPET II Pixelated APD-Based PET Scanner for High-Resolution Preclinical Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lecomte, Roger; Arpin, Louis; Beaudoin, Jean-François; Bergeron, Mélanie; Bouchard, Jonathan; Bouziri, Haithem; Cadorette, Jules; Gaudin, Émilie; Jürgensen, Nadia; Koua, Konin Calliste; Trépanier, Pierre-Yves Lauzier; Leroux, Jean-Daniel; Loignon-Houle, Francis; Njejimana, Larissa; Paillé, Maxime; Paulin, Caroline; Pepin, Catherine; Pratte, Jean-François; Samson, Arnaud; Thibaudeau, Christian [Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke, Novalgo Inc., Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, 3IT, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke (Canada); and others

    2016-08-15

    Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time and energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.

  10. Tumor imaging with PET and C-11 thymidine

    International Nuclear Information System (INIS)

    Conti, P.S.; Hilton, J.; Magee, C.A.; Anderson, J.H.

    1989-01-01

    Accurate interpretation of kinetic positron-emission tomographic (PET) data obtained following administration of C-11 thymidine requires identification of radiolabeled metabolites. The authors goal is to quantitate rapidly formed metabolites of C-11 thymidine by using reproducible high-pressure liquid chromatography (HPLC). Following coinjection of methyl-C-11 and methyl-C-14 thymidine, dogs bearing implanted glioblastoma were imaged with PET. Plasma samples were collected, and dogs were sacrificed at 60 minutes. Tissues were prepared for quantitative autoradiography and analysis of radioactivity associated with DNA, RNA protein, and acid soluble extracts. Plasma and tissue extracts were analyzed by HPLC by using C-18 reverse phase and dilute buffer mobile phase systems for the separation of catabolites and phosphorylated nucleotides

  11. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters

    International Nuclear Information System (INIS)

    Mhlanga, Joyce C.; Lodge, Martin; Carrino, John A.; Wang, Hao; Wahl, Richard L.

    2014-01-01

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with 18 F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological 18 F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p= 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted. (orig.)

  12. PET and Recycling

    Directory of Open Access Journals (Sweden)

    Funda Sevencan

    2007-08-01

    Full Text Available This review aims to clarify the need of decreasing the environmental effects caused by human and draw attention to the increasing environmental effects of plastics wastes. Plastics consist of organic molecules with high density molecules or polymers. Main resources of plastics are the residue of oil rafineries. Several advantages of plastics, have increased the usage continuously. Polyethylene Terephthalate (PET is the most commonly used plastics. PET is used to protect food, drinking water, fruit juice, alcoholic beverage, and food packing films. By the increasing interest on the environmental effects of plastic wastes, concerns on the recyclable packing materials also grew up. Also the daily use of recyclable containers consisting PET have increased. There are five steps for recycling of plastics. These steps are; using large amounts of plastics, collecting them in a big center, classifying and sorting the plastics, reproducing the polymers and obtaining new products with melted plastics. Providing a healthy recycling of plastics, the consumers should have knowledge and responsibility. The consumer should know what he/she has to do before putting the plastics in the recycling containers. Recycling containers and bags should be placed near the sources of plastic wastes. Consequently, the plastic wastes and environmental problems they cause will be on the agenda in future. [TAF Prev Med Bull. 2007; 6(4: 307-312

  13. PET and Recycling

    Directory of Open Access Journals (Sweden)

    Funda Sevencan

    2007-08-01

    Full Text Available This review aims to clarify the need of decreasing the environmental effects caused by human and draw attention to the increasing environmental effects of plastics wastes. Plastics consist of organic molecules with high density molecules or polymers. Main resources of plastics are the residue of oil rafineries. Several advantages of plastics, have increased the usage continuously. Polyethylene Terephthalate (PET is the most commonly used plastics. PET is used to protect food, drinking water, fruit juice, alcoholic beverage, and food packing films. By the increasing interest on the environmental effects of plastic wastes, concerns on the recyclable packing materials also grew up. Also the daily use of recyclable containers consisting PET have increased. There are five steps for recycling of plastics. These steps are; using large amounts of plastics, collecting them in a big center, classifying and sorting the plastics, reproducing the polymers and obtaining new products with melted plastics. Providing a healthy recycling of plastics, the consumers should have knowledge and responsibility. The consumer should know what he/she has to do before putting the plastics in the recycling containers. Recycling containers and bags should be placed near the sources of plastic wastes. Consequently, the plastic wastes and environmental problems they cause will be on the agenda in future. [TAF Prev Med Bull 2007; 6(4.000: 307-312

  14. Measurement of central μ-opioid receptor binding in vivo with PET and [11C]carfentanil: a test-retest study in healthy subjects

    International Nuclear Information System (INIS)

    Hirvonen, Jussi; Aalto, Sargo; Maksimow, Anu; Oikonen, Vesa; Naagren, Kjell; Hagelberg, Nora; Scheinin, Harry; Ingman, Kimmo; Virkkala, Jussi

    2009-01-01

    [ 11 C]Carfentanil has been widely used in positron emission tomography (PET) studies for measuring μ-opioid receptor binding in humans, but the reproducibility of the binding parameter estimates is unknown. Eight healthy volunteers were scanned twice during the same day with [ 11 C]carfentanil PET, and binding to receptors was assessed with both reference tissue and arterial plasma input-based models using region of interest (ROI) and voxel-based quantification. The two-tissue compartmental model distribution volume (V T ) was highly reproducible as indicated by low variability (VAR 0.93). BP ND (BP relative to the nondisplaceable tissue compartment) was also highly reproducible (VAR 0.90) both at ROI- and voxel-level, and reference tissue-based models provided stable estimates after 40 min. The reproducibility of [ 11 C]carfentanil binding parameter estimates is excellent with outcome measures based on both arterial plasma and reference tissue input, and a scanning time of 40 min appears sufficient. (orig.)

  15. Evaluation of PeneloPET Simulations of Biograph PET/CT Scanners

    Science.gov (United States)

    Abushab, K. M.; Herraiz, J. L.; Vicente, E.; Cal-González, J.; España, S.; Vaquero, J. J.; Jakoby, B. W.; Udías, J. M.

    2016-06-01

    Monte Carlo (MC) simulations are widely used in positron emission tomography (PET) for optimizing detector design, acquisition protocols, and evaluating corrections and reconstruction methods. PeneloPET is a MC code based on PENELOPE, for PET simulations which considers detector geometry, acquisition electronics and materials, and source definitions. While PeneloPET has been successfully employed and validated with small animal PET scanners, it required a proper validation with clinical PET scanners including time-of-flight (TOF) information. For this purpose, we chose the family of Biograph PET/CT scanners: the Biograph True-Point (B-TP), Biograph True-Point with TrueV (B-TPTV) and the Biograph mCT. They have similar block detectors and electronics, but a different number of rings and configuration. Some effective parameters of the simulations, such as the dead-time and the size of the reflectors in the detectors, were adjusted to reproduce the sensitivity and noise equivalent count (NEC) rate of the B-TPTV scanner. These parameters were then used to make predictions of experimental results such as sensitivity, NEC rate, spatial resolution, and scatter fraction (SF), from all the Biograph scanners and some variations of them (energy windows and additional rings of detectors). Predictions agree with the measured values for the three scanners, within 7% (sensitivity and NEC rate) and 5% (SF). The resolution obtained for the B-TPTV is slightly better (10%) than the experimental values. In conclusion, we have shown that PeneloPET is suitable for simulating and investigating clinical systems with good accuracy and short computational time, though some effort tuning of a few parameters of the scanners modeled may be needed in case that the full details of the scanners studied are not available.

  16. High Resolution PET with 250 micrometer LSO Detectors and Adaptive Zoom

    International Nuclear Information System (INIS)

    Cherry, Simon R.; Qi, Jinyi

    2012-01-01

    There have been impressive improvements in the performance of small-animal positron emission tomography (PET) systems since their first development in the mid 1990s, both in terms of spatial resolution and sensitivity, which have directly contributed to the increasing adoption of this technology for a wide range of biomedical applications. Nonetheless, current systems still are largely dominated by the size of the scintillator elements used in the detector. Our research predicts that developing scintillator arrays with an element size of 250 (micro)m or smaller will lead to an image resolution of 500 (micro)m when using 18F- or 64Cu-labeled radiotracers, giving a factor of 4-8 improvement in volumetric resolution over the highest resolution research systems currently in existence. This proposal had two main objectives: (i) To develop and evaluate much higher resolution and efficiency scintillator arrays that can be used in the future as the basis for detectors in a small-animal PET scanner where the spatial resolution is dominated by decay and interaction physics rather than detector size. (ii) To optimize one such high resolution, high sensitivity detector and adaptively integrate it into the existing microPET II small animal PET scanner as a 'zoom-in' detector that provides higher spatial resolution and sensitivity in a limited region close to the detector face. The knowledge gained from this project will provide valuable information for building future PET systems with a complete ring of very high-resolution detector arrays and also lay the foundations for utilizing high-resolution detectors in combination with existing PET systems for localized high-resolution imaging.

  17. {sup 18}F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters

    Energy Technology Data Exchange (ETDEWEB)

    Mhlanga, Joyce C.; Lodge, Martin [Johns Hopkins University School of Medicine, Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Carrino, John A. [Johns Hopkins University School of Medicine, Division of Musculoskeletal Radiology, The Russell H. Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Wang, Hao [Johns Hopkins University School of Medicine, Department of Oncology Biostatistics Division, Baltimore, MD (United States); Wahl, Richard L. [Johns Hopkins University School of Medicine, Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Johns Hopkins University Hospitals, Division of Nuclear Medicine, Baltimore, MD (United States)

    2014-12-15

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with {sup 18}F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological {sup 18}F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p= 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted. (orig.)

  18. Performance evaluation of a high resolution dedicated breast PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    García Hernández, Trinitat, E-mail: mtrinitat@eresa.com; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del [Department of Nuclear Medicine, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Roselló Ferrando, Joan [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Department of Physiology, University of Valencia, Valencia 46010 (Spain)

    2016-05-15

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ({sup 18}F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good

  19. Performance evaluation of a high resolution dedicated breast PET scanner

    International Nuclear Information System (INIS)

    García Hernández, Trinitat; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo; Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del; Roselló Ferrando, Joan

    2016-01-01

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ("1"8F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good performance

  20. New horizons with PET/CT in high-tech radiotherapy planning

    International Nuclear Information System (INIS)

    Hadjieva, T.

    2009-01-01

    Full text:The precise delineation of exposed volumes in the high-tech radiotherapy is a major problem. The malignoma imaging was revolutionized by PET. PET became one of the routine imaging methods in developed countries in Europe and USA. PET with 18-FDG, combined with structural and topographic representation of images by CT, currently provides the most reliable information about the location and spread of tumor. Three dimensional radiotherapy planning is a challenge in today's practice and requires the most accurate visualization of the tumor, with its functional characteristics (proliferation activity, hypoxic cells, apoptosis, neoangiogenesis) and surrounding radiosensitive normal tissue and organs. The collected information about the main indications for radiotherapy planning using PET / CT in head and neck cancers , small cell lung carcinoma and some malignant lymphomas has been discussed. The problem of false positive and false negative findings has been also considered. The protocol for 18-FDG PET / CT conducting according to the agreed consensus of the IAEA expert meeting held in 2006 is presented

  1. Improving the singles rate method for modeling accidental coincidences in high-resolution PET

    International Nuclear Information System (INIS)

    Oliver, Josep F; Rafecas, Magdalena

    2010-01-01

    Random coincidences ('randoms') are one of the main sources of image degradation in PET imaging. In order to correct for this effect, an accurate method to estimate the contribution of random events is necessary. This aspect becomes especially relevant for high-resolution PET scanners where the highest image quality is sought and accurate quantitative analysis is undertaken. One common approach to estimate randoms is the so-called singles rate method (SR) widely used because of its good statistical properties. SR is based on the measurement of the singles rate in each detector element. However, recent studies suggest that SR systematically overestimates the correct random rate. This overestimation can be particularly marked for low energy thresholds, below 250 keV used in some applications and could entail a significant image degradation. In this work, we investigate the performance of SR as a function of the activity, geometry of the source and energy acceptance window used. We also investigate the performance of an alternative method, which we call 'singles trues' (ST) that improves SR by properly modeling the presence of true coincidences in the sample. Nevertheless, in any real data acquisition the knowledge of which singles are members of a true coincidence is lost. Therefore, we propose an iterative method, STi, that provides an estimation based on ST but which only requires the knowledge of measurable quantities: prompts and singles. Due to inter-crystal scatter, for wide energy windows ST only partially corrects SR overestimations. While SR deviations are in the range 86-300% (depending on the source geometry), the ST deviations are systematically smaller and contained in the range 4-60%. STi fails to reproduce the ST results, although for not too high activities the deviation with respect to ST is only a few percent. For conventional energy windows, i.e. those without inter-crystal scatter, the ST method corrects the SR overestimations, and deviations from

  2. Quantitative assessment of the physical potential of proton beam range verification with PET/CT

    Science.gov (United States)

    Knopf, A.; Parodi, K.; Paganetti, H.; Cascio, E.; Bonab, A.; Bortfeld, T.

    2008-08-01

    A recent clinical pilot study demonstrated the feasibility of offline PET/CT range verification for proton therapy treatments. In vivo PET measurements are challenged by blood perfusion, variations of tissue compositions, patient motion and image co-registration uncertainties. Besides these biological and treatment specific factors, the accuracy of the method is constrained by the underlying physical processes. This phantom study distinguishes physical factors from other factors, assessing the reproducibility, consistency and sensitivity of the PET/CT range verification method. A spread-out Bragg-peak (SOBP) proton field was delivered to a phantom consisting of poly-methyl methacrylate (PMMA), lung and bone equivalent material slabs. PET data were acquired in listmode at a commercial PET/CT scanner available within 10 min walking distance from the proton therapy unit. The measured PET activity distributions were compared to simulations of the PET signal based on Geant4 and FLUKA Monte Carlo (MC) codes. To test the reproducibility of the measured PET signal, data from two independent measurements at the same geometrical position in the phantom were compared. Furthermore, activation depth profiles within identical material arrangements but at different positions within the irradiation field were compared to test the consistency of the measured PET signal. Finally, activation depth profiles through air/lung, air/bone and lung/bone interfaces parallel as well as at 6° to the beam direction were studied to investigate the sensitivity of the PET/CT range verification method. The reproducibility and the consistency of the measured PET signal were found to be of the same order of magnitude. They determine the physical accuracy of the PET measurement to be about 1 mm. However, range discrepancies up to 2.6 mm between two measurements and range variations up to 2.6 mm within one measurement were found at the beam edge and at the edge of the field of view (FOV) of the PET

  3. Quantitative assessment of the physical potential of proton beam range verification with PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Knopf, A; Paganetti, H; Cascio, E; Bortfeld, T [Department of Radiation Oncology, MGH and Harvard Medical School, Boston, MA 02114 (United States); Parodi, K [Heidelberg Ion Therapy Center, Heidelberg (Germany); Bonab, A [Department of Radiology, MGH and Harvard Medical School, Boston, MA 02114 (United States)

    2008-08-07

    A recent clinical pilot study demonstrated the feasibility of offline PET/CT range verification for proton therapy treatments. In vivo PET measurements are challenged by blood perfusion, variations of tissue compositions, patient motion and image co-registration uncertainties. Besides these biological and treatment specific factors, the accuracy of the method is constrained by the underlying physical processes. This phantom study distinguishes physical factors from other factors, assessing the reproducibility, consistency and sensitivity of the PET/CT range verification method. A spread-out Bragg-peak (SOBP) proton field was delivered to a phantom consisting of poly-methyl methacrylate (PMMA), lung and bone equivalent material slabs. PET data were acquired in listmode at a commercial PET/CT scanner available within 10 min walking distance from the proton therapy unit. The measured PET activity distributions were compared to simulations of the PET signal based on Geant4 and FLUKA Monte Carlo (MC) codes. To test the reproducibility of the measured PET signal, data from two independent measurements at the same geometrical position in the phantom were compared. Furthermore, activation depth profiles within identical material arrangements but at different positions within the irradiation field were compared to test the consistency of the measured PET signal. Finally, activation depth profiles through air/lung, air/bone and lung/bone interfaces parallel as well as at 6{sup 0} to the beam direction were studied to investigate the sensitivity of the PET/CT range verification method. The reproducibility and the consistency of the measured PET signal were found to be of the same order of magnitude. They determine the physical accuracy of the PET measurement to be about 1 mm. However, range discrepancies up to 2.6 mm between two measurements and range variations up to 2.6 mm within one measurement were found at the beam edge and at the edge of the field of view (FOV) of the

  4. Quantitative assessment of the physical potential of proton beam range verification with PET/CT.

    Science.gov (United States)

    Knopf, A; Parodi, K; Paganetti, H; Cascio, E; Bonab, A; Bortfeld, T

    2008-08-07

    A recent clinical pilot study demonstrated the feasibility of offline PET/CT range verification for proton therapy treatments. In vivo PET measurements are challenged by blood perfusion, variations of tissue compositions, patient motion and image co-registration uncertainties. Besides these biological and treatment specific factors, the accuracy of the method is constrained by the underlying physical processes. This phantom study distinguishes physical factors from other factors, assessing the reproducibility, consistency and sensitivity of the PET/CT range verification method. A spread-out Bragg-peak (SOBP) proton field was delivered to a phantom consisting of poly-methyl methacrylate (PMMA), lung and bone equivalent material slabs. PET data were acquired in listmode at a commercial PET/CT scanner available within 10 min walking distance from the proton therapy unit. The measured PET activity distributions were compared to simulations of the PET signal based on Geant4 and FLUKA Monte Carlo (MC) codes. To test the reproducibility of the measured PET signal, data from two independent measurements at the same geometrical position in the phantom were compared. Furthermore, activation depth profiles within identical material arrangements but at different positions within the irradiation field were compared to test the consistency of the measured PET signal. Finally, activation depth profiles through air/lung, air/bone and lung/bone interfaces parallel as well as at 6 degrees to the beam direction were studied to investigate the sensitivity of the PET/CT range verification method. The reproducibility and the consistency of the measured PET signal were found to be of the same order of magnitude. They determine the physical accuracy of the PET measurement to be about 1 mm. However, range discrepancies up to 2.6 mm between two measurements and range variations up to 2.6 mm within one measurement were found at the beam edge and at the edge of the field of view (FOV) of the

  5. PET/CT in therapy evaluation of patients with lung cancer

    DEFF Research Database (Denmark)

    Langer, Natasha Hemicke; Christensen, Tine Nøhr; Langer, Seppo W

    2014-01-01

    FDG-PET/CT is a well documented and widespread used imaging modality for the diagnosis and staging of patient with lung cancer. FDG-PET/CT is increasingly used for the assessment of treatment effects during and after chemotherapy. However, PET is not an accepted surrogate end-point for assessment...... of response rate in clinical trials. The aim of this review is to present current evidence on the use of PET in response evaluation of patients with lung cancer and to introduce the pearls and pitfalls of the PET-technology relating to response assessment. Based on this and relating to validation criteria......, including stable technology, standardization, reproducibility and broad availability, the review discusses why, despite numerous studies on response assessment indicating a possible role for FDG-PET/CT, PET still has no place in guidelines relating to response evaluation in lung cancer....

  6. Small animal simultaneous PET/MRI: initial experiences in a 9.4 T microMRI

    Energy Technology Data Exchange (ETDEWEB)

    Maramraju, Sri Harsha; Ravindranath, Bosky; Vaska, Paul; Schlyer, David J [Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY (United States); Smith, S David; Schulz, Daniela [Medical Department, Brookhaven National Laboratory, Upton, NY (United States); Junnarkar, Sachin S; Rescia, Sergio [Instrumentation Division, Brookhaven National Laboratory, Upton, NY (United States); Stoll, Sean; Purschke, Martin L; Woody, Craig L [Physics Department, Brookhaven National Laboratory, Upton, NY (United States); Southekal, Sudeepti [Brigham and Women' s Hospital, Boston, MA (United States); Pratte, Jean-Francois, E-mail: schlyer@bnl.gov [Universite de Sherbrooke, Sherbrooke, Quebec (Canada)

    2011-04-21

    We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 x 8 array of lutetium oxyorthosilicate crystals (2.22 x 2.22 x 5 mm{sup 3}) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [{sup 11}C]raclopride and 2-deoxy-2-[{sup 18}F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.

  7. Reproducibility of functional volume and activity concentration in 18F-FDG PET/CT of liver metastases in colorectal cancer.

    Science.gov (United States)

    Heijmen, Linda; de Geus-Oei, Lioe-Fee; de Wilt, Johannes H W; Visvikis, Dimitris; Hatt, Mathieu; Visser, Eric P; Bussink, Johan; Punt, Cornelis J A; Oyen, Wim J G; van Laarhoven, Hanneke W M

    2012-12-01

    Several studies showed potential for monitoring response to systemic therapy in metastatic colorectal cancer patients with (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET). Before (18)F-FDG PET can be implemented for response evaluation the repeatability should be known. This study was performed to assess the magnitude of the changes in standardized uptake value (SUV), volume and total lesion glycolysis (TLG) in colorectal liver metastases and validate the biological basis of (18)F-FDG PET in colorectal liver metastases. Twenty patients scheduled for liver metastasectomy underwent two (18)F-FDG PET scans within 1 week. Bland-Altman analysis was performed to assess repeatability of SUV(max), SUV(mean), volume and TLG. Tumours were delineated using an adaptive threshold method (PET(SBR)) and a semiautomatic fuzzy locally adaptive Bayesian (FLAB) delineation method. Coefficient of repeatability of SUV(max) and SUV(mean) were ∼39 and ∼31 %, respectively, independent of the delineation method used and image reconstruction parameters. However, repeatability was worse in recently treated patients. The FLAB delineation method improved the repeatability of the volume and TLG measurements compared to PET(SBR), from coefficients of repeatability of over 85 % to 45 % and 57 % for volume and TLG, respectively. Glucose transporter 1 (GLUT1) expression correlated to the SUV(mean). Vascularity (CD34 expression) and tumour hypoxia (carbonic anhydrase IX expression) did not correlate with (18)F-FDG PET parameters. In conclusion, repeatability of SUV(mean) and SUV(max) was mainly affected by preceding systemic therapy. The repeatability of tumour volume and TLG could be improved using more advanced and robust delineation approaches such as FLAB, which is recommended when (18)F-FDG PET is utilized for volume or TLG measurements. Improvement of repeatability of PET measurements, for instance by dynamic PET scanning protocols, is probably necessary to effectively

  8. Reproducibility of functional volume and activity concentration in 18F-FDG PET/CT of liver metastases in colorectal cancer

    International Nuclear Information System (INIS)

    Heijmen, Linda; Geus-Oei, Lioe-Fee de; Visser, Eric P.; Oyen, Wim J.G.; Wilt, Johannes H.W. de; Visvikis, Dimitris; Hatt, Mathieu; Bussink, Johan; Punt, Cornelis J.A.; Laarhoven, Hanneke W.M. van

    2012-01-01

    Several studies showed potential for monitoring response to systemic therapy in metastatic colorectal cancer patients with 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET). Before 18 F-FDG PET can be implemented for response evaluation the repeatability should be known. This study was performed to assess the magnitude of the changes in standardized uptake value (SUV), volume and total lesion glycolysis (TLG) in colorectal liver metastases and validate the biological basis of 18 F-FDG PET in colorectal liver metastases. Twenty patients scheduled for liver metastasectomy underwent two 18 F-FDG PET scans within 1 week. Bland-Altman analysis was performed to assess repeatability of SUV max , SUV mean , volume and TLG. Tumours were delineated using an adaptive threshold method (PET SBR ) and a semiautomatic fuzzy locally adaptive Bayesian (FLAB) delineation method. Coefficient of repeatability of SUV max and SUV mean were ∝39 and ∝31 %, respectively, independent of the delineation method used and image reconstruction parameters. However, repeatability was worse in recently treated patients. The FLAB delineation method improved the repeatability of the volume and TLG measurements compared to PET SBR , from coefficients of repeatability of over 85 % to 45 % and 57 % for volume and TLG, respectively. Glucose transporter 1 (GLUT1) expression correlated to the SUV mean . Vascularity (CD34 expression) and tumour hypoxia (carbonic anhydrase IX expression) did not correlate with 18 F-FDG PET parameters. In conclusion, repeatability of SUV mean and SUV max was mainly affected by preceding systemic therapy. The repeatability of tumour volume and TLG could be improved using more advanced and robust delineation approaches such as FLAB, which is recommended when 18 F-FDG PET is utilized for volume or TLG measurements. Improvement of repeatability of PET measurements, for instance by dynamic PET scanning protocols, is probably necessary to effectively use PET for

  9. PET/CT in staging of the high risk prostate cancer

    International Nuclear Information System (INIS)

    Bergero, M.A.; David, C.; Dipatto, F.; Popeneciu, V.; Ríos, L.; Faccio, F.

    2016-01-01

    Objectives: In the last decade multimodal management of the high risk prostate cancer (HRPC) is a therapeutic option in selected patients and the staging of these patients depends on the current diagnostic methods (DM) which have low diagnostic accuracy for detecting metastasis (MTS). The positron emission tomography/computed tomography (PET/CT) would have a greater diagnostic accuracy and it is presented as a better DM for staging prostate cancer (PC). The aim of this article is present 2 patients in whom PET/CT modified the therapeutic decision and conduct a literature review. Materials and methods: 2 patients with HRPC who performed PET/CT and it modified the therapeutic behavior were described and a systematic review of the literature was conducted using PubMed, Embase, SciELO and Cochrane answering the question: has PET/CT a place in HRPC staging? Results: TPET/CT has a sensitivity and specificity between 19% to 100% and 67% to 98,5 %, respectively, in assessing nodal involvement by PC and between 84% to 96% and 92.3% to 100%, respectively, in assessing bone involvement by PC. Besides PET/CT allowed to modify the therapeutic behavior between 20% to 40% of the patients with PC. Conclusions: PET/CT has good specificity and moderate sensitivity for detecting lymph node MTS and good sensitivity and specificity for detecting bone MTS. Besides PET/CT modified the therapeutic behavior in 1/3 of cases and it allowed us to modify the therapeutic behavior in our series. (authors) [es

  10. Reproducibility study of [{sup 18}F]FPP(RGD){sub 2} uptake in murine models of human tumor xenografts

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Edwin; Liu, Shuangdong; Chin, Frederick; Cheng, Zhen [Stanford University, Molecular Imaging Program at Stanford, Department of Radiology, School of Medicine, Stanford, CA (United States); Gowrishankar, Gayatri; Yaghoubi, Shahriar [Stanford University, Molecular Imaging Program at Stanford, Department of Radiology, School of Medicine, Stanford, CA (United States); Stanford University, Molecular Imaging Program at Stanford, Department of Bioengineering, School of Medicine, Stanford, CA (United States); Wedgeworth, James Patrick [Stanford University, Molecular Imaging Program at Stanford, Department of Bioengineering, School of Medicine, Stanford, CA (United States); Berndorff, Dietmar; Gekeler, Volker [Bayer Schering Pharma AG, Global Drug Discovery, Berlin (Germany); Gambhir, Sanjiv S. [Stanford University, Molecular Imaging Program at Stanford, Department of Radiology, School of Medicine, Stanford, CA (United States); Stanford University, Molecular Imaging Program at Stanford, Department of Bioengineering, School of Medicine, Stanford, CA (United States); Canary Center at Stanford for Cancer Early Detection, Nuclear Medicine, Departments of Radiology and Bioengineering, Molecular Imaging Program at Stanford, Stanford, CA (United States)

    2011-04-15

    An {sup 18}F-labeled PEGylated arginine-glycine-aspartic acid (RGD) dimer [{sup 18}F]FPP(RGD){sub 2} has been used to image tumor {alpha}{sub v}{beta}{sub 3} integrin levels in preclinical and clinical studies. Serial positron emission tomography (PET) studies may be useful for monitoring antiangiogenic therapy response or for drug screening; however, the reproducibility of serial scans has not been determined for this PET probe. The purpose of this study was to determine the reproducibility of the integrin {alpha}{sub v}{beta}{sub 3}-targeted PET probe, [{sup 18}F ]FPP(RGD){sub 2} using small animal PET. Human HCT116 colon cancer xenografts were implanted into nude mice (n = 12) in the breast and scapular region and grown to mean diameters of 5-15 mm for approximately 2.5 weeks. A 3-min acquisition was performed on a small animal PET scanner approximately 1 h after administration of [{sup 18}F]FPP(RGD){sub 2} (1.9-3.8 MBq, 50-100 {mu}Ci) via the tail vein. A second small animal PET scan was performed approximately 6 h later after reinjection of the probe to assess for reproducibility. Images were analyzed by drawing an ellipsoidal region of interest (ROI) around the tumor xenograft activity. Percentage injected dose per gram (%ID/g) values were calculated from the mean or maximum activity in the ROIs. Coefficients of variation and differences in %ID/g values between studies from the same day were calculated to determine the reproducibility. The coefficient of variation (mean {+-}SD) for %ID{sub mean}/g and %ID{sub max}/g values between [{sup 18}F]FPP(RGD){sub 2} small animal PET scans performed 6 h apart on the same day were 11.1 {+-} 7.6% and 10.4 {+-} 9.3%, respectively. The corresponding differences in %ID{sub mean}/g and %ID{sub max}/g values between scans were -0.025 {+-} 0.067 and -0.039 {+-} 0.426. Immunofluorescence studies revealed a direct relationship between extent of {alpha}{sub {nu}}{beta}{sub 3} integrin expression in tumors and tumor vasculature

  11. FDG-PET/CT based response-adapted treatment

    DEFF Research Database (Denmark)

    de Geus-Oei, Lioe-Fee; Vriens, Dennis; Arens, Anne I J

    2012-01-01

    It has been shown that [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET) provides robust and reproducible data for early metabolic response assessment in various malignancies. This led to the initiation of several prospective multicenter trials in malignant lymphoma and adenocarc...

  12. easyPET: a novel concept for an affordable tomographic system

    International Nuclear Information System (INIS)

    Arosio, V.; Caccia, M.; Castro, I.F.; Correia, P.M.M.; Mattone, C.; Moutinho, L.M.; Santoro, R.; Silva, A.L.M.; Veloso, J.F.C.A.

    2017-01-01

    The easyPET concept described here aims to reduce complexity and cost of preclinical Positron Emission Tomography (PET) scanners. The system, original in its principle and realisation, is based on a single pair of detectors and a rotating mechanism with two degrees of freedom reproducing the functionalities of an entire PET ring. The characterisation of a 2D imaging prototype, realised to assess the easyPET concept, is presented in this paper. In particular, a spatial resolution of 1±0.1 mm and a sensitivity of 0.1% with an energy threshold of 80 keV have been measured. These encouraging results, compared to the performances of commercial preclinical PET, motivate the feasibility study of a 3D system.

  13. easyPET: a novel concept for an affordable tomographic system

    Energy Technology Data Exchange (ETDEWEB)

    Arosio, V., E-mail: varosio@studenti.uninsubria.it [Dipartimento di Scienza e Alta Tecnologia, Università degli Studi dell' Insubria, Via Valleggio 11, 22100 Como (Italy); Caccia, M. [Dipartimento di Scienza e Alta Tecnologia, Università degli Studi dell' Insubria, Via Valleggio 11, 22100 Como (Italy); Castro, I.F.; Correia, P.M.M. [i3n, Departamento de Fisica, Univerdisade de Aveiro, Campus Universitario de Santiago, 3810-193 Aveiro (Portugal); Mattone, C. [Dipartimento di Scienza e Alta Tecnologia, Università degli Studi dell' Insubria, Via Valleggio 11, 22100 Como (Italy); Moutinho, L.M. [i3n, Departamento de Fisica, Univerdisade de Aveiro, Campus Universitario de Santiago, 3810-193 Aveiro (Portugal); Santoro, R. [Dipartimento di Scienza e Alta Tecnologia, Università degli Studi dell' Insubria, Via Valleggio 11, 22100 Como (Italy); Silva, A.L.M.; Veloso, J.F.C.A. [i3n, Departamento de Fisica, Univerdisade de Aveiro, Campus Universitario de Santiago, 3810-193 Aveiro (Portugal)

    2017-02-11

    The easyPET concept described here aims to reduce complexity and cost of preclinical Positron Emission Tomography (PET) scanners. The system, original in its principle and realisation, is based on a single pair of detectors and a rotating mechanism with two degrees of freedom reproducing the functionalities of an entire PET ring. The characterisation of a 2D imaging prototype, realised to assess the easyPET concept, is presented in this paper. In particular, a spatial resolution of 1±0.1 mm and a sensitivity of 0.1% with an energy threshold of 80 keV have been measured. These encouraging results, compared to the performances of commercial preclinical PET, motivate the feasibility study of a 3D system.

  14. In-beam PET at high-energy photon beams: a feasibility study

    Science.gov (United States)

    Müller, H.; Enghardt, W.

    2006-04-01

    For radiation therapy with carbon ion beams, either for the stable isotope 12C or for the radioactive one 11C, it has been demonstrated that the β+-activity distribution created or deposited, respectively, within the irradiated volume can be visualized by means of positron emission tomography (PET). The PET images provide valuable information for quality assurance and precision improvement of ion therapy. Dedicated PET scanners have been integrated into treatment sites at the Heavy Ion Medical Accelerator at Chiba (HIMAC), Japan, and the Gesellschaft für Schwerionenforschung (GSI), Germany, to make PET imaging feasible during therapeutic irradiation (in-beam PET). A similar technique may be worthwhile for radiotherapy with high-energy bremsstrahlung. In addition to monitoring the dose delivery process which in-beam PET has been primarily developed for, it may be expected that radiation response of tissue can be detected by means of in-beam PET. We investigate the applicability of PET for treatment control in the case of using bremsstrahlung spectra produced by 15-50 MeV electrons. Target volume activation due to (γ, n) reactions at energies above 20 MeV yields moderate β+-activity levels, which can be employed for imaging. The radiation from positrons produced by pair production is not presently usable because the detectors are overloaded due to the low duty factor of medical electron linear accelerators. However, the degradation of images caused by positron motion between creation and annihilation seems to be tolerable.

  15. High-performance electronics for time-of-flight PET systems

    International Nuclear Information System (INIS)

    Choong, W-S; Peng, Q; Vu, C Q; Turko, B T; Moses, W W

    2013-01-01

    We have designed and built a high-performance readout electronics system for time-of-flight positron emission tomography (TOF PET) cameras. The electronics architecture is based on the electronics for a commercial whole-body PET camera (Siemens/CPS Cardinal electronics), modified to improve the timing performance. The fundamental contributions in the electronics that can limit the timing resolution include the constant fraction discriminator (CFD), which converts the analog electrical signal from the photo-detector to a digital signal whose leading edge is time-correlated with the input signal, and the time-to-digital converter (TDC), which provides a time stamp for the CFD output. Coincident events are identified by digitally comparing the values of the time stamps. In the Cardinal electronics, the front-end processing electronics are performed by an Analog subsection board, which has two application-specific integrated circuits (ASICs), each servicing a PET block detector module. The ASIC has a built-in CFD and TDC. We found that a significant degradation in the timing resolution comes from the ASIC's CFD and TDC. Therefore, we have designed and built an improved Analog subsection board that replaces the ASIC's CFD and TDC with a high-performance CFD (made with discrete components) and TDC (using the CERN high-performance TDC ASIC). The improved Analog subsection board is used in a custom single-ring LSO-based TOF PET camera. The electronics system achieves a timing resolution of 60 ps FWHM. Prototype TOF detector modules are read out with the electronics system and give coincidence timing resolutions of 259 ps FWHM and 156 ps FWHM for detector modules coupled to LSO and LaBr 3 crystals respectively.

  16. Shear wave elastography for breast masses is highly reproducible.

    Science.gov (United States)

    Cosgrove, David O; Berg, Wendie A; Doré, Caroline J; Skyba, Danny M; Henry, Jean-Pierre; Gay, Joel; Cohen-Bacrie, Claude

    2012-05-01

    To evaluate intra- and interobserver reproducibility of shear wave elastography (SWE) for breast masses. For intraobserver reproducibility, each observer obtained three consecutive SWE images of 758 masses that were visible on ultrasound. 144 (19%) were malignant. Weighted kappa was used to assess the agreement of qualitative elastographic features; the reliability of quantitative measurements was assessed by intraclass correlation coefficients (ICC). For the interobserver reproducibility, a blinded observer reviewed images and agreement on features was determined. Mean age was 50 years; mean mass size was 13 mm. Qualitatively, SWE images were at least reasonably similar for 666/758 (87.9%). Intraclass correlation for SWE diameter, area and perimeter was almost perfect (ICC ≥ 0.94). Intraobserver reliability for maximum and mean elasticity was almost perfect (ICC = 0.84 and 0.87) and was substantial for the ratio of mass-to-fat elasticity (ICC = 0.77). Interobserver agreement was moderate for SWE homogeneity (κ = 0.57), substantial for qualitative colour assessment of maximum elasticity (κ = 0.66), fair for SWE shape (κ = 0.40), fair for B-mode mass margins (κ = 0.38), and moderate for B-mode mass shape (κ = 0.58), orientation (κ = 0.53) and BI-RADS assessment (κ = 0.59). SWE is highly reproducible for assessing elastographic features of breast masses within and across observers. SWE interpretation is at least as consistent as that of BI-RADS ultrasound B-mode features. • Shear wave ultrasound elastography can measure the stiffness of breast tissue • It provides a qualitatively and quantitatively interpretable colour-coded map of tissue stiffness • Intraobserver reproducibility of SWE is almost perfect while intraobserver reproducibility of SWE proved to be moderate to substantial • The most reproducible SWE features between observers were SWE image homogeneity and maximum elasticity.

  17. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0

    International Nuclear Information System (INIS)

    Boellaard, Ronald; Hoekstra, Otto S.; Delgado-Bolton, Roberto; Oyen, Wim J.G.; Visser, Eric; Giammarile, Francesco; Tatsch, Klaus; Eschner, Wolfgang; Verzijlbergen, Fred J.; Barrington, Sally F.; Pike, Lucy C.; Weber, Wolfgang A.; Stroobants, Sigrid; Delbeke, Dominique; Donohoe, Kevin J.; Holbrook, Scott; Graham, Michael M.; Testanera, Giorgio; Chiti, Arturo; Zijlstra, Josee; Hoekstra, Corneline J.; Pruim, Jan; Willemsen, Antoon; Arends, Bertjan; Kotzerke, Joerg; Bockisch, Andreas; Beyer, Thomas; Krause, Bernd J.

    2015-01-01

    The purpose of these guidelines is to assist physicians in recommending, performing, interpreting and reporting the results of FDG PET/CT for oncological imaging of adult patients. PET is a quantitative imaging technique and therefore requires a common quality control (QC)/quality assurance (QA) procedure to maintain the accuracy and precision of quantitation. Repeatability and reproducibility are two essential requirements for any quantitative measurement and/or imaging biomarker. Repeatability relates to the uncertainty in obtaining the same result in the same patient when he or she is examined more than once on the same system. However, imaging biomarkers should also have adequate reproducibility, i.e. the ability to yield the same result in the same patient when that patient is examined on different systems and at different imaging sites. Adequate repeatability and reproducibility are essential for the clinical management of patients and the use of FDG PET/CT within multicentre trials. A common standardised imaging procedure will help promote the appropriate use of FDG PET/CT imaging and increase the value of publications and, therefore, their contribution to evidence-based medicine. Moreover, consistency in numerical values between platforms and institutes that acquire the data will potentially enhance the role of semiquantitative and quantitative image interpretation. Precision and accuracy are additionally important as FDG PET/CT is used to evaluate tumour response as well as for diagnosis, prognosis and staging. Therefore both the previous and these new guidelines specifically aim to achieve standardised uptake value harmonisation in multicentre settings. (orig.)

  18. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0

    Energy Technology Data Exchange (ETDEWEB)

    Boellaard, Ronald; Hoekstra, Otto S. [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Delgado-Bolton, Roberto [University of La Rioja, Department of Diagnostic Imaging (Radiology) and Nuclear Medicine, San Pedro Hospital and Centre for Biomedical Research of La Rioja (CIBIR), Logrono, La Rioja (Spain); Oyen, Wim J.G.; Visser, Eric [Radboud University Nijmegen Medical Centre, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Giammarile, Francesco [Centre Hospitalier Universitaire de Lyon, Department of Nuclear Medicine, Lyon (France); Tatsch, Klaus [Municipal Hospital Karlsruhe Inc., Department of Nuclear Medicine, Karlsruhe (Germany); Eschner, Wolfgang [University of Cologne, Department of Nuclear Medicine, Cologne (Germany); Verzijlbergen, Fred J. [Erasmus Medical Center, Department of Nuclear Medicine, Rotterdam (Netherlands); Barrington, Sally F.; Pike, Lucy C. [King' s College London, King' s Health Partners, PET Imaging Centre, St Thomas' Hospital, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Weber, Wolfgang A. [Memorial Sloan Kettering Center, Department of Radiology, New York, NY (United States); Stroobants, Sigrid [Antwerp University Hospital, Department of Nuclear Medicine, Antwerp (Belgium); Delbeke, Dominique [Vanderbilt University Medical Center, Department of Radiology and Radiological Sciences, Nashville, TN (United States); Donohoe, Kevin J. [Beth Israel Deaconess Medical Center, Boston, MA (United States); Holbrook, Scott [Invivo Molecular Imaging LLC, Gray, TN (United States); Graham, Michael M. [University of Iowa, Department of Radiology, Iowa City, IA (United States); Testanera, Giorgio; Chiti, Arturo [Humanitas Clinical and Research Center, Department of Nuclear Medicine, Rozzano, MI (Italy); Zijlstra, Josee [VU University Medical Centre, Department of Hematology, Amsterdam (Netherlands); Hoekstra, Corneline J. [Jeroen Bosch Hospital, Department of Nuclear Medicine, Den Bosch (Netherlands); Pruim, Jan; Willemsen, Antoon [University Medical Centre Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Arends, Bertjan [Catharina Hospital, Department of Clinical Physics, Eindhoven (Netherlands); Kotzerke, Joerg [University Hospital Dresden, Clinic and Outpatient Clinic for Nuclear Medicine, Dresden (Germany); Bockisch, Andreas [University Hospital Essen, Clinic for Nuclear Medicine, Essen (Germany); Beyer, Thomas [Medical University of Vienna, Centre for Medical Physics and Biomedical Engineering, Vienna (Austria); Krause, Bernd J. [University Hospital Rostock, Department of Nuclear Medicine, Rostock (Germany)

    2014-12-02

    The purpose of these guidelines is to assist physicians in recommending, performing, interpreting and reporting the results of FDG PET/CT for oncological imaging of adult patients. PET is a quantitative imaging technique and therefore requires a common quality control (QC)/quality assurance (QA) procedure to maintain the accuracy and precision of quantitation. Repeatability and reproducibility are two essential requirements for any quantitative measurement and/or imaging biomarker. Repeatability relates to the uncertainty in obtaining the same result in the same patient when he or she is examined more than once on the same system. However, imaging biomarkers should also have adequate reproducibility, i.e. the ability to yield the same result in the same patient when that patient is examined on different systems and at different imaging sites. Adequate repeatability and reproducibility are essential for the clinical management of patients and the use of FDG PET/CT within multicentre trials. A common standardised imaging procedure will help promote the appropriate use of FDG PET/CT imaging and increase the value of publications and, therefore, their contribution to evidence-based medicine. Moreover, consistency in numerical values between platforms and institutes that acquire the data will potentially enhance the role of semiquantitative and quantitative image interpretation. Precision and accuracy are additionally important as FDG PET/CT is used to evaluate tumour response as well as for diagnosis, prognosis and staging. Therefore both the previous and these new guidelines specifically aim to achieve standardised uptake value harmonisation in multicentre settings. (orig.)

  19. A fully automated and reproducible level-set segmentation approach for generation of MR-based attenuation correction map of PET images in the brain employing single STE-MR imaging modality

    Energy Technology Data Exchange (ETDEWEB)

    Kazerooni, Anahita Fathi; Aarabi, Mohammad Hadi [Quantitative MR Imaging and Spectroscopy Group, Research Center for Cellular and Molecular Imaging, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Ay, Mohammadreza [Quantitative MR Imaging and Spectroscopy Group, Research Center for Cellular and Molecular Imaging, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Medical Imaging Systems Group, Research Center for Cellular and Molecular Imaging, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Rad, Hamidreza Saligheh [Quantitative MR Imaging and Spectroscopy Group, Research Center for Cellular and Molecular Imaging, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2014-07-29

    Generating MR-based attenuation correction map (μ-map) for quantitative reconstruction of PET images still remains a challenge in hybrid PET/MRI systems, mainly because cortical bone structures are indistinguishable from proximal air cavities in conventional MR images. Recently, development of short echo-time (STE) MR imaging sequences, has shown promise in differentiating cortical bone from air. However, on STE-MR images, the bone appears with discontinuous boundaries. Therefore, segmentation techniques based on intensity classification, such as thresholding or fuzzy C-means, fail to homogeneously delineate bone boundaries, especially in the presence of intrinsic noise and intensity inhomogeneity. Consequently, they cannot be fully automatized, must be fine-tuned on the case-by-case basis, and require additional morphological operations for segmentation refinement. To overcome the mentioned problems, in this study, we introduce a new fully automatic and reproducible STE-MR segmentation approach exploiting level-set in a clustering-based intensity inhomogeneity correction framework to reliably delineate bone from soft tissue and air.

  20. A fully automated and reproducible level-set segmentation approach for generation of MR-based attenuation correction map of PET images in the brain employing single STE-MR imaging modality

    International Nuclear Information System (INIS)

    Kazerooni, Anahita Fathi; Aarabi, Mohammad Hadi; Ay, Mohammadreza; Rad, Hamidreza Saligheh

    2014-01-01

    Generating MR-based attenuation correction map (μ-map) for quantitative reconstruction of PET images still remains a challenge in hybrid PET/MRI systems, mainly because cortical bone structures are indistinguishable from proximal air cavities in conventional MR images. Recently, development of short echo-time (STE) MR imaging sequences, has shown promise in differentiating cortical bone from air. However, on STE-MR images, the bone appears with discontinuous boundaries. Therefore, segmentation techniques based on intensity classification, such as thresholding or fuzzy C-means, fail to homogeneously delineate bone boundaries, especially in the presence of intrinsic noise and intensity inhomogeneity. Consequently, they cannot be fully automatized, must be fine-tuned on the case-by-case basis, and require additional morphological operations for segmentation refinement. To overcome the mentioned problems, in this study, we introduce a new fully automatic and reproducible STE-MR segmentation approach exploiting level-set in a clustering-based intensity inhomogeneity correction framework to reliably delineate bone from soft tissue and air.

  1. PETSTEP: Generation of synthetic PET lesions for fast evaluation of segmentation methods

    Science.gov (United States)

    Berthon, Beatrice; Häggström, Ida; Apte, Aditya; Beattie, Bradley J.; Kirov, Assen S.; Humm, John L.; Marshall, Christopher; Spezi, Emiliano; Larsson, Anne; Schmidtlein, C. Ross

    2016-01-01

    Purpose This work describes PETSTEP (PET Simulator of Tracers via Emission Projection): a faster and more accessible alternative to Monte Carlo (MC) simulation generating realistic PET images, for studies assessing image features and segmentation techniques. Methods PETSTEP was implemented within Matlab as open source software. It allows generating three-dimensional PET images from PET/CT data or synthetic CT and PET maps, with user-drawn lesions and user-set acquisition and reconstruction parameters. PETSTEP was used to reproduce images of the NEMA body phantom acquired on a GE Discovery 690 PET/CT scanner, and simulated with MC for the GE Discovery LS scanner, and to generate realistic Head and Neck scans. Finally the sensitivity (S) and Positive Predictive Value (PPV) of three automatic segmentation methods were compared when applied to the scanner-acquired and PETSTEP-simulated NEMA images. Results PETSTEP produced 3D phantom and clinical images within 4 and 6 min respectively on a single core 2.7 GHz computer. PETSTEP images of the NEMA phantom had mean intensities within 2% of the scanner-acquired image for both background and largest insert, and 16% larger background Full Width at Half Maximum. Similar results were obtained when comparing PETSTEP images to MC simulated data. The S and PPV obtained with simulated phantom images were statistically significantly lower than for the original images, but led to the same conclusions with respect to the evaluated segmentation methods. Conclusions PETSTEP allows fast simulation of synthetic images reproducing scanner-acquired PET data and shows great promise for the evaluation of PET segmentation methods. PMID:26321409

  2. A custom-built PET phantom design for quantitative imaging of printed distributions

    International Nuclear Information System (INIS)

    Markiewicz, P J; Angelis, G I; Kotasidis, F; Green, M; Matthews, J C; Lionheart, W R; Reader, A J

    2011-01-01

    This note presents a practical approach to a custom-made design of PET phantoms enabling the use of digital radioactive distributions with high quantitative accuracy and spatial resolution. The phantom design allows planar sources of any radioactivity distribution to be imaged in transaxial and axial (sagittal or coronal) planes. Although the design presented here is specially adapted to the high-resolution research tomograph (HRRT), the presented methods can be adapted to almost any PET scanner. Although the presented phantom design has many advantages, a number of practical issues had to be overcome such as positioning of the printed source, calibration, uniformity and reproducibility of printing. A well counter (WC) was used in the calibration procedure to find the nonlinear relationship between digital voxel intensities and the actual measured radioactive concentrations. Repeated printing together with WC measurements and computed radiography (CR) using phosphor imaging plates (IP) were used to evaluate the reproducibility and uniformity of such printing. Results show satisfactory printing uniformity and reproducibility; however, calibration is dependent on the printing mode and the physical state of the cartridge. As a demonstration of the utility of using printed phantoms, the image resolution and quantitative accuracy of reconstructed HRRT images are assessed. There is very good quantitative agreement in the calibration procedure between HRRT, CR and WC measurements. However, the high resolution of CR and its quantitative accuracy supported by WC measurements made it possible to show the degraded resolution of HRRT brain images caused by the partial-volume effect and the limits of iterative image reconstruction. (note)

  3. Automatic delineation of brain regions on MRI and PET images from the pig.

    Science.gov (United States)

    Villadsen, Jonas; Hansen, Hanne D; Jørgensen, Louise M; Keller, Sune H; Andersen, Flemming L; Petersen, Ida N; Knudsen, Gitte M; Svarer, Claus

    2018-01-15

    The increasing use of the pig as a research model in neuroimaging requires standardized processing tools. For example, extraction of regional dynamic time series from brain PET images requires parcellation procedures that benefit from being automated. Manual inter-modality spatial normalization to a MRI atlas is operator-dependent, time-consuming, and can be inaccurate with lack of cortical radiotracer binding or skull uptake. A parcellated PET template that allows for automatic spatial normalization to PET images of any radiotracer. MRI and [ 11 C]Cimbi-36 PET scans obtained in sixteen pigs made the basis for the atlas. The high resolution MRI scans allowed for creation of an accurately averaged MRI template. By aligning the within-subject PET scans to their MRI counterparts, an averaged PET template was created in the same space. We developed an automatic procedure for spatial normalization of the averaged PET template to new PET images and hereby facilitated transfer of the atlas regional parcellation. Evaluation of the automatic spatial normalization procedure found the median voxel displacement to be 0.22±0.08mm using the MRI template with individual MRI images and 0.92±0.26mm using the PET template with individual [ 11 C]Cimbi-36 PET images. We tested the automatic procedure by assessing eleven PET radiotracers with different kinetics and spatial distributions by using perfusion-weighted images of early PET time frames. We here present an automatic procedure for accurate and reproducible spatial normalization and parcellation of pig PET images of any radiotracer with reasonable blood-brain barrier penetration. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Quantification, Variability, and Reproducibility of Basal Skeletal Muscle Glucose Uptake in Healthy Humans Using 18F-FDG PET/CT.

    Science.gov (United States)

    Gheysens, Olivier; Postnov, Andrey; Deroose, Christophe M; Vandermeulen, Corinne; de Hoon, Jan; Declercq, Ruben; Dennie, Justin; Mixson, Lori; De Lepeleire, Inge; Van Laere, Koen; Klimas, Michael; Chakravarthy, Manu V

    2015-10-01

    The quantification and variability of skeletal muscle glucose utilization (SMGU) in healthy subjects under basal (low insulin) conditions are poorly known. This information is essential early in clinical drug development to effectively interrogate novel pharmacologic interventions that modulate glucose uptake. The aim of this study was to determine test-retest characteristics and variability of SMGU within and between healthy subjects under basal conditions. Furthermore, different kinetic modeling strategies were evaluated to find the best-fitting model to assess SMGU studied by 18F-FDG. Six healthy male volunteers underwent 2 dynamic 18F-FDG PET/CT scans with an interval of 24 h. Subjects were admitted to the clinical unit to minimize variability in daily activities and food intake and restrict physical activity. 18F-FDG PET/CT scans of gluteal and quadriceps muscle area were obtained with arterial input. Regions of interest were drawn over the muscle area to obtain time-activity curves and standardized uptake values (SUVs) between 60 and 90 min. Spectral analysis of the data and kinetic modeling was performed using 2-tissue-irreversible (2T3K), 2-tissue-reversible, and 3-tissue-sequential-irreversible (3T5KS) models. Reproducibility was assessed by intraclass correlation coefficients (ICCs) and within-subject coefficient of variation (WSCV). SUVs in gluteal and quadriceps areas were 0.56±0.09 and 0.64±0.07. ICCs (with 90% confidence intervals in parentheses) were 0.88 (0.64-0.96) and 0.96 (0.82-0.99), respectively, for gluteal and quadriceps muscles, and WSCV for gluteal and quadriceps muscles was 2.2% and 3.6%, respectively. The rate of glucose uptake into muscle was 0.0016±0.0004 mL/mL⋅min, with an ICC of 0.94 (0.93-0.95) and WSCV of 6.6% for the 3T5KS model, whereas an ICC of 0.98 (0.92-1.00) and WSCV of 2.8% was obtained for the 2T3K model. 3T5KS demonstrated the best fit to the measured experimental points. Minimal variability in skeletal muscle glucose

  5. Dynamic 18F-fluoride small animal PET to noninvasively assess renal function in rats

    International Nuclear Information System (INIS)

    Schnoeckel, Uta; Stegger, Lars; Schaefers, Klaus P.; Hermann, Sven; Schober, Otmar; Schaefers, Michael; Reuter, Stefan; Schlatter, Eberhard; Gabriels, Gert

    2008-01-01

    Renal function can be quantified by both laboratory and scintigraphic methods. In the case of small animal diagnostics, scintigraphic image-based methods are ideal since they can assess split renal function, work noninvasively, and can be repeated. The aim of this study is to validate a 18 F-PET-based method to quantify renal function in rats. Fluoride clearance was calculated from a dynamic whole body listmode acquisition of 60 min length in a small animal PET scanner following an i.v. injection of 15 MBq 18 F-fluoride. Volumes of interest (VOIs) were placed in the left ventricle and the bladder as well as traced around the kidney contours. The respective time-activity curves (TAC) were calculated. The renal 18 F-clearance was calculated by the ratio of the total renal excreted activity (bladder VOI) and the integral of the blood TAC. PET-derived renal function was validated by intraindividual measurements of creatinine clearance (n=23), urea clearance (n=23), and tubular excretion rate (TER-MAG3). The split renal function was derived from the injection of the clinically available radionuclide 99m Tc-mercaptotriglycine by blood sampling and planar renography (n=8). In all animals studied, PET revealed high-quality TACs. PET-derived renal fluoride clearance was linearly correlated with intraindividual laboratory measures (PET vs. creatinine: r=0.78; PET vs. urea: r=0.73; PET vs. TER-MAG3: r=0.73). Split function was comparable ( 18 F-PET vs. MAG3-renography: r=0.98). PET-derived measures were highly reproducible. 18 F-PET is able to noninvasively assess renal function in rats and provides a significant potential for serial studies in different experimental scenarios. (orig.)

  6. Potential Applications of PET/MR Imaging in Cardiology.

    Science.gov (United States)

    Ratib, Osman; Nkoulou, René

    2014-06-01

    Recent advances in hybrid PET/MR imaging have opened new perspectives for cardiovascular applications. Although cardiac MR imaging has gained wider adoption for routine clinical applications, PET images remain the reference in many applications for which objective analysis of metabolic and physiologic parameters is needed. In particular, in cardiovascular diseases-more specifically, coronary artery disease-the use of quantitative and measurable parameters in a reproducible way is essential for the management of therapeutic decisions and patient follow-up. Functional MR images and dynamic assessment of myocardial perfusion from transit of intravascular contrast medium can provide useful criteria for identifying areas of decreased myocardial perfusion or for assessing tissue viability from late contrast enhancement of scar tissue. PET images, however, will provide more quantitative data on true tissue perfusion and metabolism. Quantitative myocardial flow can also lead to accurate assessment of coronary flow reserve. The combination of both modalities will therefore provide complementary data that can be expected to improve the accuracy and reproducibility of diagnostic procedures. But the true potential of hybrid PET/MR imaging may reside in applications beyond the domain of coronary artery disease. The combination of both modalities in assessment of other cardiac diseases such as inflammation and of other systemic diseases can also be envisioned. It is also predicted that the 2 modalities combined could help characterize atherosclerotic plaques and differentiate plaques with a high risk of rupture from stable plaques. In the future, the development of new tracers will also open new perspectives in evaluating myocardial remodeling and in assessing the kinetics of stem cell therapy in myocardial infarction. New tracers will also provide new means for evaluating alterations in cardiac innervation, angiogenesis, and even the assessment of reporter gene technologies

  7. A useful PET probe [11C]BU99008 with ultra-high specific radioactivity for small animal PET imaging of I2-imidazoline receptors in the hypothalamus

    International Nuclear Information System (INIS)

    Kawamura, Kazunori; Shimoda, Yoko; Yui, Joji; Zhang, Yiding; Yamasaki, Tomoteru; Wakizaka, Hidekatsu; Hatori, Akiko; Xie, Lin; Kumata, Katsushi; Fujinaga, Masayuki; Ogawa, Masanao; Kurihara, Yusuke; Nengaki, Nobuki; Zhang, Ming-Rong

    2017-01-01

    Introduction: A positron emission tomography (PET) probe with ultra-high specific radioactivity (SA) enables measuring high receptor specific binding in brain regions by avoiding mass effect of the PET probe itself. It has been reported that PET probe with ultra-high SA can detect small change caused by endogenous or exogenous ligand. Recently, Kealey et al. developed [ 11 C]BU99008, a more potent PET probe for I 2 -imidazoline receptors (I 2 Rs) imaging, with a conventional SA (mean 76 GBq/μmol) showed higher specific binding in the brain. Here, to detect small change of specific binding for I 2 Rs caused by endogenous or exogenous ligand in an extremely small region, such as hypothalamus in the brain, we synthesized and evaluated [ 11 C]BU99008 with ultra-high SA as a useful PET probe for small-animal PET imaging of I 2 Rs. Methods: [ 11 C]BU99008 was prepared by [ 11 C]methylation of N-desmethyl precursor with [ 11 C]methyl iodide. Biodistribution, metabolite analysis, and brain PET studies were conducted in rats. Results: [ 11 C]BU99008 with ultra-high SA in the range of 5400–16,600 GBq/μmol were successfully synthesized (n = 7), and had appropriate radioactivity for in vivo study. In the biodistribution study, the mean radioactivity levels in all investigated tissues except for the kidney did not show significant difference between [ 11 C]BU99008 with ultra-high SA and that with conventional SA. In the metabolite analysis, the percentage of unchanged [ 11 C]BU99008 at 30 min after the injection of probes with ultra-high and conventional SA was similar in rat brain and plasma. In the PET study of rats' brain, radioactivity level (AUC 30–60 min ) in the hypothalamus of rats injected with [ 11 C]BU99008 with ultra-high SA (64 [SUV ∙ min]) was significantly higher than that observed for that with conventional SA (50 [SUV ∙ min]). The specific binding of [ 11 C]BU99008 with ultra-high SA (86% of total binding) for I 2 R was higher than that of

  8. PetIGA-MF: a multi-field high-performance toolbox for structure-preserving B-splines spaces

    KAUST Repository

    Sarmiento, Adel; Cô rtes, A.M.A.; Garcia, D.A.; Dalcin, Lisandro; Collier, N.; Calo, V.M.

    2016-01-01

    We describe a high-performance solution framework for isogeometric discrete differential forms based on B-splines: PetIGA-MF. Built on top of PetIGA, an open-source library we have built and developed over the last decade, PetIGA-MF is a general

  9. Reproducibility of functional volume and activity concentration in {sup 18}F-FDG PET/CT of liver metastases in colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Heijmen, Linda [Radboud University Medical Centre, Department of Medical Oncology 452, PO Box 9101, Nijmegen (Netherlands); Geus-Oei, Lioe-Fee de; Visser, Eric P.; Oyen, Wim J.G. [Radboud University Medical Centre, Department of Nuclear Medicine, Nijmegen (Netherlands); Wilt, Johannes H.W. de [Radboud University Medical Centre, Department of Surgery, Nijmegen (Netherlands); Visvikis, Dimitris; Hatt, Mathieu [LaTIM, INSERM U1101, Brest (France); Bussink, Johan [Radboud University Medical Centre, Department of Radiation Oncology, Nijmegen (Netherlands); Punt, Cornelis J.A. [University of Amsterdam, Department of Medical Oncology, Academic Medical Centre, Amsterdam (Netherlands); Laarhoven, Hanneke W.M. van [Radboud University Medical Centre, Department of Medical Oncology 452, PO Box 9101, Nijmegen (Netherlands); University of Amsterdam, Department of Medical Oncology, Academic Medical Centre, Amsterdam (Netherlands)

    2012-12-15

    Several studies showed potential for monitoring response to systemic therapy in metastatic colorectal cancer patients with {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET). Before {sup 18}F-FDG PET can be implemented for response evaluation the repeatability should be known. This study was performed to assess the magnitude of the changes in standardized uptake value (SUV), volume and total lesion glycolysis (TLG) in colorectal liver metastases and validate the biological basis of {sup 18}F-FDG PET in colorectal liver metastases. Twenty patients scheduled for liver metastasectomy underwent two {sup 18}F-FDG PET scans within 1 week. Bland-Altman analysis was performed to assess repeatability of SUV{sub max}, SUV{sub mean}, volume and TLG. Tumours were delineated using an adaptive threshold method (PET{sub SBR}) and a semiautomatic fuzzy locally adaptive Bayesian (FLAB) delineation method. Coefficient of repeatability of SUV{sub max} and SUV{sub mean} were {proportional_to}39 and {proportional_to}31 %, respectively, independent of the delineation method used and image reconstruction parameters. However, repeatability was worse in recently treated patients. The FLAB delineation method improved the repeatability of the volume and TLG measurements compared to PET{sub SBR}, from coefficients of repeatability of over 85 % to 45 % and 57 % for volume and TLG, respectively. Glucose transporter 1 (GLUT1) expression correlated to the SUV{sub mean}. Vascularity (CD34 expression) and tumour hypoxia (carbonic anhydrase IX expression) did not correlate with {sup 18}F-FDG PET parameters. In conclusion, repeatability of SUV{sub mean} and SUV{sub max} was mainly affected by preceding systemic therapy. The repeatability of tumour volume and TLG could be improved using more advanced and robust delineation approaches such as FLAB, which is recommended when {sup 18}F-FDG PET is utilized for volume or TLG measurements. Improvement of repeatability of PET measurements

  10. Variability and reproducibility of rubidium-82 kinetic parameters in the myocardium of the anesthetized canine

    International Nuclear Information System (INIS)

    Coxson, P.G.; Brennan, K.M.; Huesman, R.H.

    1995-01-01

    Kinetic analysis of 82 Rb (I) dynamic PET data produces quantitative measures which could be used to evaluate ischemic heart disease. These measures have the potential to generate objective comparisons of different patients or the same patient at different times. To achieve this potential, it is essential to determine the variability and reproducibility of the kinetic parameters. A total of 48 I dynamic PET datasets were acquired from two pure bred beagles. Each animal underwent eight I PET studies with essentially the same protocol for three successive weeks. Data were acquired with the Donner 600-Crystal Positron Tomograph (PET600). In each week, single-slice dynamic I PET datasets were collected with the animal at rest at three different gantry positions separated by 5 mm. Additional dataset were collected after dipyridamole infusion and after administration of aminophylline to induce a return to rest. A two-compartment kinetic model with correction for myocardial vasculature and spillover from the left ventricular blood pool was used to analyze the dynamic datasets. Model parameters for uptake (k 1 ), washout (k 2 ) and vascular fraction (f v ) were estimated in 11-14 myocardial regions of interest (ROIs) using a weighted least-squares criterion. Statistical fluctuation due to the PET acquisition process was minimized by using a relatively high I dose (about 30 mCi) to take advantage of the high count rate capacity of the PET600. The variation in mean k 1 , where the mean is taken over the myocardial ROIs was 10%-20% (Dog 1) and 15%-50% (Dog 2) among the rest studies conducted on the same data. Similar variation was evident in comparing studies in the same animal for different weeks. Spatial and temporal variation in estimates of the uptake rate (k 1 ) of I in the resting myocardium of the anesthetized canine are small in relation to the functional increase in k 1 , following dipyridamole stress. 17 refs., 14 figs

  11. Accuracy and reproducibility of tumor positioning during prolonged and multi-modality animal imaging studies

    International Nuclear Information System (INIS)

    Zhang Mutian; Huang Minming; Le, Carl; Zanzonico, Pat B; Ling, C Clifton; Koutcher, Jason A; Humm, John L; Claus, Filip; Kolbert, Katherine S; Martin, Kyle

    2008-01-01

    Dedicated small-animal imaging devices, e.g. positron emission tomography (PET), computed tomography (CT) and magnetic resonance imaging (MRI) scanners, are being increasingly used for translational molecular imaging studies. The objective of this work was to determine the positional accuracy and precision with which tumors in situ can be reliably and reproducibly imaged on dedicated small-animal imaging equipment. We designed, fabricated and tested a custom rodent cradle with a stereotactic template to facilitate registration among image sets. To quantify tumor motion during our small-animal imaging protocols, 'gold standard' multi-modality point markers were inserted into tumor masses on the hind limbs of rats. Three types of imaging examination were then performed with the animals continuously anesthetized and immobilized: (i) consecutive microPET and MR images of tumor xenografts in which the animals remained in the same scanner for 2 h duration, (ii) multi-modality imaging studies in which the animals were transported between distant imaging devices and (iii) serial microPET scans in which the animals were repositioned in the same scanner for subsequent images. Our results showed that the animal tumor moved by less than 0.2-0.3 mm over a continuous 2 h microPET or MR imaging session. The process of transporting the animal between instruments introduced additional errors of ∼0.2 mm. In serial animal imaging studies, the positioning reproducibility within ∼0.8 mm could be obtained.

  12. A new PET detector concept for compact preclinical high-resolution hybrid MR-PET

    Science.gov (United States)

    Berneking, Arne; Gola, Alberto; Ferri, Alessandro; Finster, Felix; Rucatti, Daniele; Paternoster, Giovanni; Jon Shah, N.; Piemonte, Claudio; Lerche, Christoph

    2018-04-01

    This work presents a new PET detector concept for compact preclinical hybrid MR-PET. The detector concept is based on Linearly-Graded SiPM produced with current FBK RGB-HD technology. One 7.75 mm x 7.75 mm large sensor chip is coupled with optical grease to a black coated 8 mm x 8 mm large and 3 mm thick monolithic LYSO crystal. The readout is obtained from four readout channels with the linear encoding based on integrated resistors and the Center of Gravity approach. To characterize the new detector concept, the spatial and energy resolutions were measured. Therefore, the measurement setup was prepared to radiate a collimated beam to 25 different points perpendicular to the monolithic scintillator crystal. Starting in the center point of the crystal at 0 mm / 0 mm and sampling a grid with a pitch of 1.75 mm, all significant points of the detector were covered by the collimator beam. The measured intrinsic spatial resolution (FWHM) was 0.74 +/- 0.01 mm in x- and 0.69 +/- 0.01 mm in the y-direction at the center of the detector. At the same point, the measured energy resolution (FWHM) was 13.01 +/- 0.05 %. The mean intrinsic spatial resolution (FWHM) over the whole detector was 0.80 +/- 0.28 mm in x- and 0.72 +/- 0.19 mm in y-direction. The energy resolution (FWHM) of the detector was between 13 and 17.3 % with an average energy resolution of 15.7 +/- 1.0 %. Due to the reduced thickness, the sensitivity of this gamma detector is low but still higher than pixelated designs with the same thickness due to the monolithic crystals. Combining compact design, high spatial resolution, and high sensitivity, the detector concept is particularly suitable for applications where the scanner bore size is limited and high resolution is required - as is the case in small animal hybrid MR-PET.

  13. Dynamic {sup 18}F-fluoride small animal PET to noninvasively assess renal function in rats

    Energy Technology Data Exchange (ETDEWEB)

    Schnoeckel, Uta; Stegger, Lars; Schaefers, Klaus P.; Hermann, Sven; Schober, Otmar; Schaefers, Michael [Klinik und Poliklinik fuer Nuklearmedizin, Muenster (Germany); Reuter, Stefan; Schlatter, Eberhard; Gabriels, Gert [Universitaetsklinikum Muenster, Medizinische Klinik und Poliklinik D, Experimentelle Nephrologie, Muenster (Germany)

    2008-12-15

    Renal function can be quantified by both laboratory and scintigraphic methods. In the case of small animal diagnostics, scintigraphic image-based methods are ideal since they can assess split renal function, work noninvasively, and can be repeated. The aim of this study is to validate a {sup 18}F-PET-based method to quantify renal function in rats. Fluoride clearance was calculated from a dynamic whole body listmode acquisition of 60 min length in a small animal PET scanner following an i.v. injection of 15 MBq {sup 18}F-fluoride. Volumes of interest (VOIs) were placed in the left ventricle and the bladder as well as traced around the kidney contours. The respective time-activity curves (TAC) were calculated. The renal {sup 18}F-clearance was calculated by the ratio of the total renal excreted activity (bladder VOI) and the integral of the blood TAC. PET-derived renal function was validated by intraindividual measurements of creatinine clearance (n=23), urea clearance (n=23), and tubular excretion rate (TER-MAG3). The split renal function was derived from the injection of the clinically available radionuclide {sup 99m}Tc-mercaptotriglycine by blood sampling and planar renography (n=8). In all animals studied, PET revealed high-quality TACs. PET-derived renal fluoride clearance was linearly correlated with intraindividual laboratory measures (PET vs. creatinine: r=0.78; PET vs. urea: r=0.73; PET vs. TER-MAG3: r=0.73). Split function was comparable ({sup 18}F-PET vs. MAG3-renography: r=0.98). PET-derived measures were highly reproducible. {sup 18}F-PET is able to noninvasively assess renal function in rats and provides a significant potential for serial studies in different experimental scenarios. (orig.)

  14. Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

    OpenAIRE

    Dang, J; Lecoq, P; Tavernier, S; Lasaygues, P; Mensah, S; Zhang, D C; Auffray, E; Frisch, B; Varela, J; Wan, M X; Felix, N

    2011-01-01

    International audience; Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allo...

  15. A multi-atlas based method for automated anatomical rat brain MRI segmentation and extraction of PET activity.

    Science.gov (United States)

    Lancelot, Sophie; Roche, Roxane; Slimen, Afifa; Bouillot, Caroline; Levigoureux, Elise; Langlois, Jean-Baptiste; Zimmer, Luc; Costes, Nicolas

    2014-01-01

    Preclinical in vivo imaging requires precise and reproducible delineation of brain structures. Manual segmentation is time consuming and operator dependent. Automated segmentation as usually performed via single atlas registration fails to account for anatomo-physiological variability. We present, evaluate, and make available a multi-atlas approach for automatically segmenting rat brain MRI and extracting PET activies. High-resolution 7T 2DT2 MR images of 12 Sprague-Dawley rat brains were manually segmented into 27-VOI label volumes using detailed protocols. Automated methods were developed with 7/12 atlas datasets, i.e. the MRIs and their associated label volumes. MRIs were registered to a common space, where an MRI template and a maximum probability atlas were created. Three automated methods were tested: 1/registering individual MRIs to the template, and using a single atlas (SA), 2/using the maximum probability atlas (MP), and 3/registering the MRIs from the multi-atlas dataset to an individual MRI, propagating the label volumes and fusing them in individual MRI space (propagation & fusion, PF). Evaluation was performed on the five remaining rats which additionally underwent [18F]FDG PET. Automated and manual segmentations were compared for morphometric performance (assessed by comparing volume bias and Dice overlap index) and functional performance (evaluated by comparing extracted PET measures). Only the SA method showed volume bias. Dice indices were significantly different between methods (PF>MP>SA). PET regional measures were more accurate with multi-atlas methods than with SA method. Multi-atlas methods outperform SA for automated anatomical brain segmentation and PET measure's extraction. They perform comparably to manual segmentation for FDG-PET quantification. Multi-atlas methods are suitable for rapid reproducible VOI analyses.

  16. New DOI identification approach for high-resolution PET detectors

    International Nuclear Information System (INIS)

    Choghadi, Amin; Takahashi, Hiroyuki; Shimazoe, Kenji

    2016-01-01

    Depth-of-interaction (DOI) Identification in positron emission tomography (PET) detectors is getting importance as it improves spatial resolution in both conventional and time-of-flight (TOF) PET, and coincidence time resolution (CTR) in TOF-PET. In both prototypes, spatial resolution is affected by parallax error caused by length of scintillator crystals. This long length also contributes substantial timing uncertainty to the time resolution of TOF-PET. Through DOI identification, both parallax error and the timing uncertainty caused by the length of crystal can be resolved. In this work, a novel approach to estimate DOI was investigated, enjoying the interference of absorbance spectrum of scintillator crystals with their emission spectrum. Because the absorption length is close to zero for shorter wavelengths of crystal emission spectrum, the counts in this range of spectrum highly depend on DOI; that is, higher counts corresponds to deeper interactions. The ratio of counts in this range to the total counts is a good measure to estimate DOI. In order to extract such ratio, two photodetectors for each crystal are used and an optical filter is mounted only on top of one of them. The ratio of filtered output to non-filtered output can be utilized as DOI estimator. For a 2×2×20 mm 3 GAGG:Ce scintillator, 8-mm DOI resolution achieved in our simulations. (author)

  17. A Case of Esophageal Leiomyoma Showing High FDG Uptake on F-18 FDG PET

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jai Hyuen [College of Medicine, Cheonan (Korea, Republic of); Ryu, Jin Sook [Asan Medical Center, University of Ulsan College of Medicine (Korea, Republic of)

    2008-08-15

    An esophageal leiomyoma is the most common benign tumor of the esophagus mainly occurred in intramural portion. Occasionally, it is difficult to discriminate esophageal malignancy from large leiomyoma. Although F-18 FDG PET has been used for differentiating malignant from benign disease, false-positive cases have been reported. Recently, uterine leiomyoma has been reported to have relatively high F-18 FDG uptake in some patients but little is known about how an esophageal leiomyoma might be showed on F-18 FDG PET. We report a case of esophageal leiomyoma that showed high FDG uptake on PET images.

  18. A Case of Esophageal Leiomyoma Showing High FDG Uptake on F-18 FDG PET

    International Nuclear Information System (INIS)

    Lee, Jai Hyuen; Ryu, Jin Sook

    2008-01-01

    An esophageal leiomyoma is the most common benign tumor of the esophagus mainly occurred in intramural portion. Occasionally, it is difficult to discriminate esophageal malignancy from large leiomyoma. Although F-18 FDG PET has been used for differentiating malignant from benign disease, false-positive cases have been reported. Recently, uterine leiomyoma has been reported to have relatively high F-18 FDG uptake in some patients but little is known about how an esophageal leiomyoma might be showed on F-18 FDG PET. We report a case of esophageal leiomyoma that showed high FDG uptake on PET images

  19. Layer-by-Layer Assembly of Polyelectrolyte Multilayer onto PET Fabric for Highly Tunable Dyeing with Water Soluble Dyestuffs

    Directory of Open Access Journals (Sweden)

    Shili Xiao

    2017-12-01

    Full Text Available Poly(ethyleneterephthalate (PET is a multi-purpose and widely used synthetic polymer in many industrial fields because of its remarkable advantages such as low cost, light weight, high toughness and resistance to chemicals, and high abrasion resistance. However, PET suffers from poor dyeability due to its non-polar nature, benzene ring structure as well as high crystallinity. In this study, PET fabrics were firstly treated with an alkaline solution to produce carboxylic acid functional groups on the surface of the PET fabric, and then was modified by polyelectrolyte polymer through the electrostatic layer-by-layer self-assembly technology. The polyelectrolyte multilayer-deposited PET fabric was characterized using scanning electron microscopy SEM, contact angle, Fourier transform infrared (FTIR and X-ray photoelectron spectroscopy (XPS. The dyeability of PET fabrics before and after surface modification was systematically investigated. It showed that the dye-uptake of the polyelectrolyte multilayer-deposited PET fabric has been enhanced compared to that of the pristine PET fabric. In addition, its dyeability is strongly dependent on the surface property of the polyelectrolyte multilayer-deposited PET fabric and the properties of dyestuffs.

  20. Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis

    International Nuclear Information System (INIS)

    Chow, Tiffany W; Verhoeff, Nicolaas PLG; Takeshita, Shinichiro; Honjo, Kie; Pataky, Christina E; St Jacques, Peggy L; Kusano, Maggie L; Caldwell, Curtis B; Ramirez, Joel; Black, Sandra

    2007-01-01

    As imaging centers produce higher resolution research scans, the number of man-hours required to process regional data has become a major concern. Comparison of automated vs. manual methodology has not been reported for functional imaging. We explored validation of using automation to delineate regions of interest on positron emission tomography (PET) scans. The purpose of this study was to ascertain improvements in image processing time and reproducibility of a semi-automated brain region extraction (SABRE) method over manual delineation of regions of interest (ROIs). We compared 2 sets of partial volume corrected serotonin 1a receptor binding potentials (BPs) resulting from manual vs. semi-automated methods. BPs were obtained from subjects meeting consensus criteria for frontotemporal degeneration and from age- and gender-matched healthy controls. Two trained raters provided each set of data to conduct comparisons of inter-rater mean image processing time, rank order of BPs for 9 PET scans, intra- and inter-rater intraclass correlation coefficients (ICC), repeatability coefficients (RC), percentages of the average parameter value (RM%), and effect sizes of either method. SABRE saved approximately 3 hours of processing time per PET subject over manual delineation (p < .001). Quality of the SABRE BP results was preserved relative to the rank order of subjects by manual methods. Intra- and inter-rater ICC were high (>0.8) for both methods. RC and RM% were lower for the manual method across all ROIs, indicating less intra-rater variance across PET subjects' BPs. SABRE demonstrated significant time savings and no significant difference in reproducibility over manual methods, justifying the use of SABRE in serotonin 1a receptor radioligand PET imaging analysis. This implies that semi-automated ROI delineation is a valid methodology for future PET imaging analysis

  1. Combined 18F-Fluciclovine PET/MRI Shows Potential for Detection and Characterization of High-Risk Prostate Cancer.

    Science.gov (United States)

    Elschot, Mattijs; Selnæs, Kirsten M; Sandsmark, Elise; Krüger-Stokke, Brage; Størkersen, Øystein; Giskeødegård, Guro F; Tessem, May-Britt; Moestue, Siver A; Bertilsson, Helena; Bathen, Tone F

    2018-05-01

    The objective of this study was to investigate whether quantitative imaging features derived from combined 18 F-fluciclovine PET/multiparametric MRI show potential for detection and characterization of primary prostate cancer. Methods: Twenty-eight patients diagnosed with high-risk prostate cancer underwent simultaneous 18 F-fluciclovine PET/MRI before radical prostatectomy. Volumes of interest (VOIs) for prostate tumors, benign prostatic hyperplasia (BPH) nodules, prostatitis, and healthy tissue were delineated on T2-weighted images, using histology as a reference. Tumor VOIs were marked as high-grade (≥Gleason grade group 3) or not. MRI and PET features were extracted on the voxel and VOI levels. Partial least-squared discriminant analysis (PLS-DA) with double leave-one-patient-out cross-validation was performed to distinguish tumors from benign tissue (BPH, prostatitis, or healthy tissue) and high-grade tumors from other tissue (low-grade tumors or benign tissue). The performance levels of PET, MRI, and combined PET/MRI features were compared using the area under the receiver-operating-characteristic curve (AUC). Results: Voxel and VOI features were extracted from 40 tumor VOIs (26 high-grade), 36 BPH VOIs, 6 prostatitis VOIs, and 37 healthy-tissue VOIs. PET/MRI performed better than MRI and PET alone for distinguishing tumors from benign tissue (AUCs of 87%, 81%, and 83%, respectively, at the voxel level and 96%, 93%, and 93%, respectively, at the VOI level) and high-grade tumors from other tissue (AUCs of 85%, 79%, and 81%, respectively, at the voxel level and 93%, 93%, and 91%, respectively, at the VOI level). T2-weighted MRI, diffusion-weighted MRI, and PET features were the most important for classification. Conclusion: Combined 18 F-fluciclovine PET/multiparametric MRI shows potential for improving detection and characterization of high-risk prostate cancer, in comparison to MRI and PET alone. © 2018 by the Society of Nuclear Medicine and Molecular

  2. 18F-Fluorodeoxyglucose positron emission tomography pulmonary imaging in idiopathic pulmonary fibrosis is reproducible: implications for future clinical trials

    International Nuclear Information System (INIS)

    Win, Thida; Lambrou, Tryphon; Hutton, Brian F.; Kayani, Irfan; Endozo, Raymondo; Shortman, Robert I.; Groves, Ashley M.; Screaton, Nicholas J.; Porter, Joanna C.; Maher, Toby M.; Lukey, Pauline

    2012-01-01

    Noninvasive markers of disease activity in patients with idiopathic pulmonary fibrosis (IPF) are lacking. We performed this study to investigate the reproducibility of pulmonary 18 F-FDG PET/CT in patients with IPF. The study group comprised 13 patients (11 men, 2 women; mean age 71.1 ± 9.9 years) with IPF recruited for two thoracic 18 F-FDG PET/CT studies performed within 2 weeks of each other. All patients were diagnosed with IPF in consensus at multidisciplinary meetings as a result of typical clinical, high-resolution CT and pulmonary function test features. Three methods for evaluating pulmonary 18 F-FDG uptake were used. The maximal 18 F-FDG pulmonary uptake (SUVmax) in the lungs was determined using manual region-of-interest placement. An 18 F-FDG uptake intensity histogram was automatically constructed from segmented lungs to evaluate the distribution of SUVs. Finally, mean SUV was determined for volumes-of-interest in pulmonary regions with interstitial lung changes identified on CT scans. Processing included correction for tissue fraction effects. Bland-Altman analysis was performed and interclass correlation coefficients (ICC) were determined to assess the reproducibility between the first and second PET scans, as well as the level of intraobserver and interobserver agreement. The mean time between the two scans was 6.3 ± 4.3 days. The interscan ICCs for pulmonary SUVmax analysis and mean SUV corrected for tissue fraction effects were 0.90 and 0.91, respectively. Intensity histograms were different in only 1 of the 13 paired studies. Intraobserver agreement was also excellent (0.80 and 0.85, respectively). Some bias was observed between observers, suggesting that serial studies would benefit from analysis by the same observer. This study demonstrated that there is excellent short-term reproducibility in pulmonary 18 F-FDG uptake in patients with IPF. (orig.)

  3. Clinical Application of F-18 FDG PET (PET/CT) in Malignancy of Unknown Origin

    International Nuclear Information System (INIS)

    Kim, Byung Il

    2008-01-01

    Diagnosis of primary origin site in the management of malignancy of unknown origin (MUO) is the most important issue. According to the histopathologic subtype of primary lesion, specialized treatment can be given and survival gain is expected. F-18 FDG PET (PET/CT) has been estimated as useful in detection of primary lesion with high sensitivity and moderate specificity. F-18 FDG PET (PET/CT) study before conventional studies is also recommended because it has high diagnostic performance compared to conventional studies. Although there has few data, F-18 FDG PET (PET/CT) is expected to be useful in diagnosis of recurrence, restaging, evaluation of treatment effect, considering that PET (PET/CT) has been reported as useful in other malignancies

  4. Clinical Application of F-18 FDG PET (PET/CT) in Colo-rectal and Anal Cancer

    International Nuclear Information System (INIS)

    Kim, Byung Il

    2008-01-01

    In the management of colo-retal and anal cancer, accurate staging, treatment evaluation, early detection of recurrence are main clinical problems. F-18 FDG PET (PET/CT) has been reported as useful in the management of colo-rectal and anal cancer because that PET has high diagnostic performance comparing to conventional studies. In case of liver metastases, for confirmation of no extrahepatic metastases, in case of high risk of metastasis, for avoiding unnecessary operation, PET (PET/CT) is expected more useful. In anal cancer, PET is expected useful in lymph node staging. For the early prediction of chemotherapy or radiation therapy effect PET has been reported as useful, also. In early detection of recurrence by PET, cost-benefit advantages has been suggested, also. PET/CT is expected to have higher diagnostic performance than PET alone

  5. F-FDG PET/CT (PET/CT) influences management in patients with known or suspected pancreatic cancer

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Kalff, Victor; Cherk, Martin H.; Yap, Kenneth SK.; Evans, Peter; Kelly, Michael J.

    2009-01-01

    Full text: Objective: To assess the impact on clinical management of PET/CT in patients with known or suspected pancreatic cancer. Methods: Between April 2006 and September 2008,25 PET/CT scans were performed using a dedicated PET/CT (22 scans) or a coincidence hybrid PET/CT camera (3 scans) in 23 patients with known or suspected pancreatic cancer. 17 scans were performed for initial evaluation and 8 for restaging of disease. The pre-PET/CT management plan and for intent were prospectively recorded in all cases. The post-PET/CT management plan was determined from the medical record and for discussions with treating clinicians. The impact of PET/CT on management was classified as High, Medium, Low or None, defined using ANZAPNM PET data collection project criteria. Follow-up was used to reconcile any discordance between PET/CT and conventional imaging. Results: Overall, PET/CT management impact was classified as high (n equal 7), medium (n equal 4), low (n equal 10) or none (n equal 4). Impact was either high or medium in l l/25 patients (44%) (95% confidence interval; 24 - 64%). Impact was high in 4/17 patients imaged for initial evaluation, predominantly by clarifying equivocal lesions on conventional imaging. In restaged patients, PET/CT impact was high in 3/8, and it correctly modified disease extent in 5/8. In the 16 discordant studies, PET/CT assessment was correct in 10, conventional imaging in 4 and there was insufficient information in 2. Conclusion: PET/CT has high or medium management impact in 44% of patients imaged for known or suspected pancreatic cancer, more commonly during restaging. Discordant PET/CT results were usually correct.

  6. Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Paulus, Daniel H.; Thorwath, Daniela; Schmidt, Holger; Quick, Harald H.

    2014-01-01

    Purpose: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. Methods: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. Results: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. Conclusions: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the

  7. Highly Efficient Reproducible Perovskite Solar Cells Prepared by Low-Temperature Processing

    Directory of Open Access Journals (Sweden)

    Hao Hu

    2016-04-01

    Full Text Available In this work, we describe the role of the different layers in perovskite solar cells to achieve reproducible, ~16% efficient perovskite solar cells. We used a planar device architecture with PEDOT:PSS on the bottom, followed by the perovskite layer and an evaporated C60 layer before deposition of the top electrode. No high temperature annealing step is needed, which also allows processing on flexible plastic substrates. Only the optimization of all of these layers leads to highly efficient and reproducible results. In this work, we describe the effects of different processing conditions, especially the influence of the C60 top layer on the device performance.

  8. International validation study for interim PET in ABVD-treated, advanced-stage hodgkin lymphoma

    DEFF Research Database (Denmark)

    Biggi, Alberto; Gallamini, Andrea; Chauvie, Stephane

    2013-01-01

    At present, there are no standard criteria that have been validated for interim PET reporting in lymphoma. In 2009, an international workshop attended by hematologists and nuclear medicine experts in Deauville, France, proposed to develop simple and reproducible rules for interim PET reporting...... in lymphoma. Accordingly, an international validation study was undertaken with the primary aim of validating the prognostic role of interim PET using the Deauville 5-point score to evaluate images and with the secondary aim of measuring concordance rates among reviewers using the same 5-point score...

  9. Imaging results and TOF studies with axial PET detectors

    Science.gov (United States)

    Joram, Christian

    2013-12-01

    We have developed a fully operational PET demonstrator setup which allows true 3D reconstruction of the 511 keV photons and therefore leads to practically parallax free images. The AX-PET concept is based on thin 100 mm long scintillation crystals (LYSO), axially oriented and arranged in layers around the field of view. Layers of wavelength shifting plastic strips mounted in between the crystal layers give the axial coordinate. Both crystals and WLS strips are individually read out by G-APD (SiPM) photodetectors. The fully scalable concept overcomes the dilemma of sensitivity versus spatial resolution which is inherent to classical PET designs. A demonstrator set-up based on two axial modules was exhaustively characterized using point-like sources, phantoms filled with radiotracer and finally rats and a mouse. The results entirely meet the performance expectations (PET concept making use of the novel digital SiPM detectors by Philips. After reproducing comparable energy and spatial resolution on a small digital AX-PET set-up with 100 mm long crystals, we demonstrated a coincidence resolving time of about 210 ps FWHM.

  10. {sup 18}F-Fluorodeoxyglucose positron emission tomography pulmonary imaging in idiopathic pulmonary fibrosis is reproducible: implications for future clinical trials

    Energy Technology Data Exchange (ETDEWEB)

    Win, Thida [Lister Hospital, Respiratory Medicine, Stevenage (United Kingdom); Lambrou, Tryphon; Hutton, Brian F.; Kayani, Irfan; Endozo, Raymondo; Shortman, Robert I.; Groves, Ashley M. [UCL/UCH, Institute of Nuclear Medicine, London (United Kingdom); Screaton, Nicholas J. [Papworth Hospital, Radiology Department, Cambridge (United Kingdom); Porter, Joanna C. [UCL/UCH, Centre for Respiratory Diseases, London (United Kingdom); Maher, Toby M. [Royal Brompton Hospital, Interstitial Lung Disease Unit, London (United Kingdom); Lukey, Pauline [GSK, Fibrosis DPU, Research and Development, Stevenage (United Kingdom)

    2012-03-15

    Noninvasive markers of disease activity in patients with idiopathic pulmonary fibrosis (IPF) are lacking. We performed this study to investigate the reproducibility of pulmonary {sup 18}F-FDG PET/CT in patients with IPF. The study group comprised 13 patients (11 men, 2 women; mean age 71.1 {+-} 9.9 years) with IPF recruited for two thoracic {sup 18}F-FDG PET/CT studies performed within 2 weeks of each other. All patients were diagnosed with IPF in consensus at multidisciplinary meetings as a result of typical clinical, high-resolution CT and pulmonary function test features. Three methods for evaluating pulmonary {sup 18}F-FDG uptake were used. The maximal {sup 18}F-FDG pulmonary uptake (SUVmax) in the lungs was determined using manual region-of-interest placement. An {sup 18}F-FDG uptake intensity histogram was automatically constructed from segmented lungs to evaluate the distribution of SUVs. Finally, mean SUV was determined for volumes-of-interest in pulmonary regions with interstitial lung changes identified on CT scans. Processing included correction for tissue fraction effects. Bland-Altman analysis was performed and interclass correlation coefficients (ICC) were determined to assess the reproducibility between the first and second PET scans, as well as the level of intraobserver and interobserver agreement. The mean time between the two scans was 6.3 {+-} 4.3 days. The interscan ICCs for pulmonary SUVmax analysis and mean SUV corrected for tissue fraction effects were 0.90 and 0.91, respectively. Intensity histograms were different in only 1 of the 13 paired studies. Intraobserver agreement was also excellent (0.80 and 0.85, respectively). Some bias was observed between observers, suggesting that serial studies would benefit from analysis by the same observer. This study demonstrated that there is excellent short-term reproducibility in pulmonary {sup 18}F-FDG uptake in patients with IPF. (orig.)

  11. 3D conditional generative adversarial networks for high-quality PET image estimation at low dose.

    Science.gov (United States)

    Wang, Yan; Yu, Biting; Wang, Lei; Zu, Chen; Lalush, David S; Lin, Weili; Wu, Xi; Zhou, Jiliu; Shen, Dinggang; Zhou, Luping

    2018-07-01

    Positron emission tomography (PET) is a widely used imaging modality, providing insight into both the biochemical and physiological processes of human body. Usually, a full dose radioactive tracer is required to obtain high-quality PET images for clinical needs. This inevitably raises concerns about potential health hazards. On the other hand, dose reduction may cause the increased noise in the reconstructed PET images, which impacts the image quality to a certain extent. In this paper, in order to reduce the radiation exposure while maintaining the high quality of PET images, we propose a novel method based on 3D conditional generative adversarial networks (3D c-GANs) to estimate the high-quality full-dose PET images from low-dose ones. Generative adversarial networks (GANs) include a generator network and a discriminator network which are trained simultaneously with the goal of one beating the other. Similar to GANs, in the proposed 3D c-GANs, we condition the model on an input low-dose PET image and generate a corresponding output full-dose PET image. Specifically, to render the same underlying information between the low-dose and full-dose PET images, a 3D U-net-like deep architecture which can combine hierarchical features by using skip connection is designed as the generator network to synthesize the full-dose image. In order to guarantee the synthesized PET image to be close to the real one, we take into account of the estimation error loss in addition to the discriminator feedback to train the generator network. Furthermore, a concatenated 3D c-GANs based progressive refinement scheme is also proposed to further improve the quality of estimated images. Validation was done on a real human brain dataset including both the normal subjects and the subjects diagnosed as mild cognitive impairment (MCI). Experimental results show that our proposed 3D c-GANs method outperforms the benchmark methods and achieves much better performance than the state

  12. Evaluation of static physics performance of the jPET-D4 by Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Tomoyuki [Allied Health Sciences, Kitasato University, Kitasato 1-15-1, Sagamihara, Kanagawa, 228-8555 (Japan); Yoshida, Eiji [Molecular Imaging Centre, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage, Chiba, 263-8555 (Japan); Kobayashi, Ayako [Graduate School of Human Health Sciences, Tokyo Metropolitan University, Arakawa, Tokyo, 116-8551 (Japan); Shibuya, Kengo [Molecular Imaging Centre, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage, Chiba, 263-8555 (Japan); Nishikido, Fumihiko [Molecular Imaging Centre, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage, Chiba, 263-8555 (Japan); Kobayashi, Tetsuya [Graduate School of Science and Technology, Chiba University, 1-33 Yayoi, Inage, Chiba, 263-8522 (Japan); Suga, Mikio [Graduate School of Science and Technology, Chiba University, 1-33 Yayoi, Inage, Chiba, 263-8522 (Japan); Yamaya, Taiga [Molecular Imaging Centre, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage, Chiba, 263-8555 (Japan); Kitamura, Keishi [Shimadzu Corporation, 1 Nishinokyo-kuwabara-cho, Nakagyo-ku, Kyoto, 604-8511 (Japan); Maruyama, Koichi [Allied Health Sciences, Kitasato University, Kitasato 1-15-1, Sagamihara, Kanagawa, 228-8555 (Japan); Murayama, Hideo [Molecular Imaging Centre, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage, Chiba, 263-8555 (Japan)

    2007-01-07

    The jPET-D4 is the first PET scanner to introduce a unique four-layer depth-of-interaction (DOI) detector scheme in order to achieve high sensitivity and uniform high spatial resolution. This paper compares measurement and Monte Carlo simulation results of the static physics performance of this prototype research PET scanner. Measurement results include single and coincidence energy spectra, point and line source sensitivities, axial sensitivity profile (slice profile) and scatter fraction. We use GATE (Geant4 application for tomographic emission) as a Monte Carlo radiation transport model. Experimental results are reproduced well by the simulation model with reasonable assumptions on characteristic responses of the DOI detectors. In a previous study, the jPET-D4 was shown to provide a uniform spatial resolution as good as 3 mm (FHWM). In the present study, we demonstrate that a high sensitivity, 11.3 {+-} 0.5%, is provided at the FOV centre. However, about three-fourths of this sensitivity is related to multiple-crystal events, for which some misidentification of the crystal cannot be avoided. Therefore, it is crucial to develop a more efficient way to identify the crystal of interaction and to reduce misidentification in order to make use of these high performance values simultaneously. We expect that effective sensitivity can be improved by replacing the GSO crystals with more absorptive crystals such as BGO and LSO. The results we describe here are essential to take full advantage of the next generation PET systems that have DOI recognition capability.

  13. Prototype of high resolution PET using resistive electrode position sensitive CdTe detectors

    International Nuclear Information System (INIS)

    Kikuchi, Yohei; Ishii, Keizo; Matsuyama, Shigeo; Yamazaki, Hiromichi

    2008-01-01

    Downsizing detector elements makes it possible that spatial resolutions of positron emission tomography (PET) cameras are improved very much. From this point of view, semiconductor detectors are preferable. To obtain high resolution, the pixel type or the multi strip type of semiconductor detectors can be used. However, in this case, there is a low packing ratio problem, because a dead area between detector arrays cannot be neglected. Here, we propose the use of position sensitive semiconductor detectors with resistive electrode. The CdTe detector is promising as a detector for PET camera because of its high sensitivity. In this paper, we report development of prototype of high resolution PET using resistive electrode position sensitive CdTe detectors. We made 1-dimensional position sensitive CdTe detectors experimentally by changing the electrode thickness. We obtained 750 A as an appropriate thickness of position sensitive detectors, and evaluated the performance of the detector using a collimated 241 Am source. A good position resolution of 1.2 mm full width half maximum (FWHM) was obtained. On the basis of the fundamental development of resistive electrode position sensitive detectors, we constructed a prototype of high resolution PET which was a dual head type and was consisted of thirty-two 1-dimensional position sensitive detectors. In conclusion, we obtained high resolutions which are 0.75 mm (FWHM) in transaxial, and 1.5 mm (FWHM) in axial. (author)

  14. Development of a Si-PM-based high-resolution PET system for small animals

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Imaizumi, Masao; Watabe, Tadashi; Shimosegawa, Eku; Hatazawa, Jun; Watabe, Hiroshi; Kanai, Yasukazu

    2010-01-01

    A Geiger-mode avalanche photodiode (Si-PM) is a promising photodetector for PET, especially for use in a magnetic resonance imaging (MRI) system, because it has high gain and is less sensitive to a static magnetic field. We developed a Si-PM-based depth-of-interaction (DOI) PET system for small animals. Hamamatsu 4 x 4 Si-PM arrays (S11065-025P) were used for its detector blocks. Two types of LGSO scintillator of 0.75 mol% Ce (decay time: ∼45 ns; 1.1 mm x 1.2 mm x 5 mm) and 0.025 mol% Ce (decay time: ∼31 ns; 1.1 mm x 1.2 mm x 6 mm) were optically coupled in the DOI direction to form a DOI detector, arranged in a 11 x 9 matrix, and optically coupled to the Si-PM array. Pulse shape analysis was used for the DOI detection of these two types of LGSOs. Sixteen detector blocks were arranged in a 68 mm diameter ring to form the PET system. Spatial resolution was 1.6 mm FWHM and sensitivity was 0.6% at the center of the field of view. High-resolution mouse and rat images were successfully obtained using the PET system. We confirmed that the developed Si-PM-based PET system is promising for molecular imaging research.

  15. Cross calibration of the Siemens mMR: easily acquired accurate PET phantom measurements, long term stability and reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Sune H [Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Jakoby, Bjorn [University of Surrey, Guildford (United Kingdom); Hansen, Adam Espe; Svalling, Susanne; Klausen, Thomas L [Rigshospitalet, University of Copenhagen, Copenhagen (Denmark)

    2015-05-18

    We present a quick and easy method to perform quantitatively accurate PET scans of typical water-filled PET plastic shell phantoms on the Siemens mMR PET/MR scanner. We perform regular cross calibrations (Xcals) of our PET scanners, including the Siemens mMR PET/MR, with a Siemens mCT water phantom. We evaluate the mMR cross calibration stability over a 3-year period. Recently, the mMR software (VB20P) offered the option of using predefined μ-maps. We evaluated this option by using either the predefined μ-map of the long mMR water phantom or a system-integrated user defined CT-based μ-map of the mCT water phantom used for Xcal. On 54 cross calibrations that were acquired over 3 years, the mMR on average underestimated the concentration by 16% due to the use of MR-based μ-maps. The mMR produced the narrowest range and lowest standard deviation of the Xcal ratios, implying it and is the most stable of the 6 scanners included in this study over a 3 year period. With correctly segmented μ-maps, the mMR produced Xcal ratios of 1.00-1.02, well within the acceptance range [0.95-1.05]. Measuring the concentration in a centrally placed cylindrical VOI allows for some robustness against misregistration of the μ-maps but it should be no more than a few millimeters in the x-y plane, while the tolerance is larger on the z-axis (when, as always with PET, keeping clear of the axial edges of the FOV). The mMR is the most stable scanner in this study and the mean underestimation is no longer an issue with the easily accessible μ-map, which in all 7 tests resulted in correct Xcal ratios. We will share the user defined μ-map of the mCT phantom and the protocol with interested mMR users.

  16. Cross calibration of the Siemens mMR: easily acquired accurate PET phantom measurements, long term stability and reproducibility

    International Nuclear Information System (INIS)

    Keller, Sune H; Jakoby, Bjorn; Hansen, Adam Espe; Svalling, Susanne; Klausen, Thomas L

    2015-01-01

    We present a quick and easy method to perform quantitatively accurate PET scans of typical water-filled PET plastic shell phantoms on the Siemens mMR PET/MR scanner. We perform regular cross calibrations (Xcals) of our PET scanners, including the Siemens mMR PET/MR, with a Siemens mCT water phantom. We evaluate the mMR cross calibration stability over a 3-year period. Recently, the mMR software (VB20P) offered the option of using predefined μ-maps. We evaluated this option by using either the predefined μ-map of the long mMR water phantom or a system-integrated user defined CT-based μ-map of the mCT water phantom used for Xcal. On 54 cross calibrations that were acquired over 3 years, the mMR on average underestimated the concentration by 16% due to the use of MR-based μ-maps. The mMR produced the narrowest range and lowest standard deviation of the Xcal ratios, implying it and is the most stable of the 6 scanners included in this study over a 3 year period. With correctly segmented μ-maps, the mMR produced Xcal ratios of 1.00-1.02, well within the acceptance range [0.95-1.05]. Measuring the concentration in a centrally placed cylindrical VOI allows for some robustness against misregistration of the μ-maps but it should be no more than a few millimeters in the x-y plane, while the tolerance is larger on the z-axis (when, as always with PET, keeping clear of the axial edges of the FOV). The mMR is the most stable scanner in this study and the mean underestimation is no longer an issue with the easily accessible μ-map, which in all 7 tests resulted in correct Xcal ratios. We will share the user defined μ-map of the mCT phantom and the protocol with interested mMR users.

  17. High performance detector head for PET and PET/MR with continuous crystals and SiPMs

    International Nuclear Information System (INIS)

    Llosá, G.; Barrillon, P.; Barrio, J.; Bisogni, M.G.; Cabello, J.; Del Guerra, A.; Etxebeste, A.; Gillam, J.E.; Lacasta, C.; Oliver, J.F.; Rafecas, M.; Solaz, C.; Stankova, V.; La Taille, C. de

    2013-01-01

    A high resolution PET detector head for small animal PET applications has been developed. The detector is composed of a 12mm×12mm continuous LYSO crystal coupled to a 64-channel monolithic SiPM matrix from FBK-irst. Crystal thicknesses of 5 mm and 10 mm have been tested, both yielding an intrinsic spatial resolution around 0.7 mm FWHM with a position determination algorithm that can also provide depth-of-interaction information. The detectors have been tested in a rotating system that makes it possible to acquire tomographic data and reconstruct images of 22 Na sources. An image reconstruction method specifically adapted for continuous crystals has been employed. The Full Width at Half Maximum measured from a point source reconstructed with ML–EM was 0.7 mm with the 5 mm crystal and 0.8 mm with the 10 mm crystal

  18. High-resolution PET [Positron Emission Tomography] for Medical Science Studies

    Science.gov (United States)

    Budinger, T. F.; Derenzo, S. E.; Huesman, R. H.; Jagust, W. J.; Valk, P. E.

    1989-09-01

    One of the unexpected fruits of basic physics research and the computer revolution is the noninvasive imaging power available to today's physician. Technologies that were strictly the province of research scientists only a decade or two ago now serve as the foundations for such standard diagnostic tools as x-ray computer tomography (CT), magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), ultrasound, single photon emission computed tomography (SPECT), and positron emission tomography (PET). Furthermore, prompted by the needs of both the practicing physician and the clinical researcher, efforts to improve these technologies continue. This booklet endeavors to describe the advantages of achieving high resolution in PET imaging.

  19. Au coated PS nanopillars as a highly ordered and reproducible SERS substrate

    Science.gov (United States)

    Kim, Yong-Tae; Schilling, Joerg; Schweizer, Stefan L.; Sauer, Guido; Wehrspohn, Ralf B.

    2017-07-01

    Noble metal nanostructures with nanometer gap size provide strong surface-enhanced Raman scattering (SERS) which can be used to detect trace amounts of chemical and biological molecules. Although several approaches were reported to obtain active SERS substrates, it still remains a challenge to fabricate SERS substrates with high sensitivity and reproducibility using low-cost techniques. In this article, we report on the fabrication of Au sputtered PS nanopillars based on a template synthetic method as highly ordered and reproducible SERS substrates. The SERS substrates are fabricated by anodic aluminum oxide (AAO) template-assisted infiltration of polystyrene (PS) resulting in hemispherical structures, and a following Au sputtering process. The optimum gap size between adjacent PS nanopillars and thickness of the Au layers for high SERS sensitivity are investigated. Using the Au sputtered PS nanopillars as an active SERS substrate, the Raman signal of 4-methylbenzenethiol (4-MBT) with a concentration down to 10-9 M is identified with good signal reproducibility, showing great potential as promising tool for SERS-based detection.

  20. Development of PET insert for simultaneous PET/MR imaging of human brain

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jiwoong; Choi, Yong; Jung, Jin Ho; Kim, Sangsu; Im, Ki Chun; Lim, Hyun Keong [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul (Korea, Republic of); Oh, Changheun; Park, HyunWook; Cho, Gyuseong [Departments of Electrical Engineering and Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon (Korea, Republic of)

    2014-07-29

    Recently, there has been great interest on the development of combined PET/MR, which is a useful tool for both functional and anatomic imaging. The purpose of this study was to develop a MR compatible PET insert for simultaneous PET and MR imaging of human brain and to evaluate the performance of the hybrid PET-MRI. The PET insert consisted of 18 detector blocks arranged in a ring of 390 mm diameter with 60 mm axial FOV. Each detector block was composed of 4 × 4 matrix of detector modules, each of which consisted of a 4 × 4 array LYSO coupled to a 4 × 4 GAPD array. The PET gantry was shielded with gold-plated conductive fabric tapes. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuits (PDCs) and then transferred to FPGA-embedded DAQ modules. The PDCs and DAQ modules were enclosed in an aluminum box and located at the rear of the MR bore inside MRI room. 3-T human MRIs of two different vendors were used to evaluate the MR compatibility of developed PET insert. No significant changes of the PET performance and the homogeneity of MR images caused by the non-compatibility of PET-MRI were observed with the 2 different MRIs. The signal intensities of MR images were slightly degraded (<3.6%) with the both MRI systems. The difference between independently and simultaneously acquired PET images of brain phantom was negligibly small (<4.3%). High quality simultaneous brain PET and MRI of 3 normal volunteers were successfully acquired. Experimental results indicate that the high performance compact and lightweight PET insert for hybrid PET/MRI, which could be utilized with the MRI from various manufactures, can be developed using GAPD arrays and charge signal transmission method proposed in this study.

  1. Application of PET and PET/CT imaging for cancer screening

    International Nuclear Information System (INIS)

    Chen Yenkung; Hu Fenglan; Shen Yehyou; Liao, A.C.; Hung, T.Z.; Su, Chentau; Chen Liangkuang

    2004-01-01

    The aim of this study was to evaluate the potential application of 18F-fluorodeoxyglucose (FDG) Positron Emission Tomography (PET) and PET/CT for cancer screening in asymptomatic individuals. Methods: The subjects consisted of 3631 physical check up examinees (1947 men, 1684 women; mean age ±SD, 52.1±8.2 y) with non-specific medical histories. Whole-body FDG PET (or PET/CT), ultrasound and tumor markers were performed on all patients. Focal hypermetabolic areas with intensities equal to or exceeding the level of FDG uptake in the brain and bladder were considered abnormal and interpreted as neoplasia. Follow-up periods were longer than one year. Results: Among the 3631 FDG PET (including 1687 PET/CT), ultrasound and tumor markers examinations, malignant tumors were discovered in 47 examinees (1.29%). PET findings were true-positive in 38 of the 47 cancers (80.9%). In addition, 32 of the 47 cancers were performed with the PET-CT scan. PET detected cancer lesions in 28 of the 32 examinees. However, the CT detected cancer lesions in only 15 of 32 examinees. Conclusion: The sensitivity of FDG PET in the detection of a wide variety of cancers is high. Most cancer can be detected with FDG PET in a resectable stage. CT of the PET/CT for localization and characteristics of the lesion shows an increased specificity of the PET scan. Using ultrasound and tumor markers may complement the PET scan in cancer screening for hepatic and urologic neoplasms. (authors)

  2. Indeterminate findings on oncologic PET/CT: What difference dose PET/MRI make?

    Energy Technology Data Exchange (ETDEWEB)

    Fraum, Tyler J.; Fowler, Kathryn J.; McConathy, Jonathan; Dehdashti, Farokh [Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis (United States)

    2016-12-15

    Positron emission tomography/computed tomography (PET/CT) with 2-deoxy-2-[{sup 18}F]fluoro-D-glucose (FDG) has become the standard of care for the initial staging and subsequent treatment response assessment of many different malignancies. Despite this success, PET/CT is often supplemented by MRI to improve assessment of local tumor invasion and to facilitate detection of lesions in organs with high background FDG uptake. Consequently, PET/MRI has the potential to expand the clinical value of PET examinations by increasing reader certainty and reducing the need for subsequent imaging. This study evaluates the ability of FDG-PET/MRI to clarify findings initially deemed indeterminate on clinical FDG-PET/CT studies. A total of 190 oncology patients underwent whole-body PET/CT, immediately followed by PET/MRI utilizing the same FDG administration. Each PET/CT was interpreted by our institution's nuclear medicine service as a standard-of-care clinical examination. Review of these PET/CT reports identified 31 patients (16 %) with indeterminate findings. Two readers evaluated all 31 PET/CT studies, followed by the corresponding PET/MRI studies. A consensus was reached for each case, and changes in interpretation directly resulting from PET/MRI review were recorded. Interpretations were then correlated with follow-up imaging, pathology results, and other diagnostic studies. In 18 of 31 cases with indeterminate findings on PET/CT, PET/MRI resulted in a more definitive interpretation by facilitating the differentiation of infection/inflammation from malignancy (15/18), the accurate localization of FDG-avid lesions (2/18), and the characterization of incidental non-FDG-avid solid organ lesions (1/18). Explanations for improved reader certainty with PET/MRI included the superior soft tissue contrast of MRI and the ability to assess cellular density with diffusion-weighted imaging. The majority (12/18) of such cases had an appropriate standard of reference; in all 12 cases

  3. Indeterminate findings on oncologic PET/CT: What difference dose PET/MRI make?

    International Nuclear Information System (INIS)

    Fraum, Tyler J.; Fowler, Kathryn J.; McConathy, Jonathan; Dehdashti, Farokh

    2016-01-01

    Positron emission tomography/computed tomography (PET/CT) with 2-deoxy-2-["1"8F]fluoro-D-glucose (FDG) has become the standard of care for the initial staging and subsequent treatment response assessment of many different malignancies. Despite this success, PET/CT is often supplemented by MRI to improve assessment of local tumor invasion and to facilitate detection of lesions in organs with high background FDG uptake. Consequently, PET/MRI has the potential to expand the clinical value of PET examinations by increasing reader certainty and reducing the need for subsequent imaging. This study evaluates the ability of FDG-PET/MRI to clarify findings initially deemed indeterminate on clinical FDG-PET/CT studies. A total of 190 oncology patients underwent whole-body PET/CT, immediately followed by PET/MRI utilizing the same FDG administration. Each PET/CT was interpreted by our institution's nuclear medicine service as a standard-of-care clinical examination. Review of these PET/CT reports identified 31 patients (16 %) with indeterminate findings. Two readers evaluated all 31 PET/CT studies, followed by the corresponding PET/MRI studies. A consensus was reached for each case, and changes in interpretation directly resulting from PET/MRI review were recorded. Interpretations were then correlated with follow-up imaging, pathology results, and other diagnostic studies. In 18 of 31 cases with indeterminate findings on PET/CT, PET/MRI resulted in a more definitive interpretation by facilitating the differentiation of infection/inflammation from malignancy (15/18), the accurate localization of FDG-avid lesions (2/18), and the characterization of incidental non-FDG-avid solid organ lesions (1/18). Explanations for improved reader certainty with PET/MRI included the superior soft tissue contrast of MRI and the ability to assess cellular density with diffusion-weighted imaging. The majority (12/18) of such cases had an appropriate standard of reference; in all 12 cases, the

  4. Preliminary report on the development of a high resolution PET camera using semiconductor detectors

    International Nuclear Information System (INIS)

    Kikuchi, Yohei; Ishii, Keizo; Yamazaki, Hiromichi; Matsuyama, Shigeo; Yamaguchi, Takashi; Yamamoto, Yusuke; Sato, Takemi; Aoki, Yasushi; Aoki, Kenichi

    2005-01-01

    We are developing a PET camera using small semiconductor detectors, whose resolution is equivalent to the physical limit of spatial resolution. First, a coincidence system of 16 Schottky CdTe detectors of 0.5 mm width obtained a resolution of <1 mm and it was confirmed that the Schottky CdTe detector is suitable for high resolution PET. Next, the performance of a pair of 32 channel CdTe arrays (1.2 mm width per channel) was investigated for the development of the prototype of high resolution PET. The time resolution between opposing detector pair was 13 ns (FWHM) when high voltage (700 V) was applied. The image of a 0.6 mm diameter point source was obtained in an experiment with opposing detector arrays using four channels, indicating that, a higher resolution can be achieved with the 32 channel CdTe array

  5. 18F-FDG PET and PET/CT in Burkitt's lymphoma

    International Nuclear Information System (INIS)

    Karantanis, Dimitrios; Durski, Jolanta M.; Lowe, Val J.; Nathan, Mark A.; Mullan, Brian P.; Georgiou, Evangelos; Johnston, Patrick B.; Wiseman, Gregory A.

    2010-01-01

    Objective: To explore the value of 18 F fluorodeoxy-glucose (FDG) positron emission tomography (PET) in Burkitt's lymphoma. Methods: All Burkitt's lymphoma patients referred for FDG PET or FDG PET/computed tomography (CT) exams at our institution from June 2003 to June 2006 were included. Selected patients were followed and clinical information was reviewed retrospectively. Results from FDG PET-PET/CT, as blindly reviewed by a consensus of two experienced readers, were compared with the status of the disease as determined by other laboratory, clinical and imaging exams and clinical follow-up. FDG PET-PET/CT results were classified as true positive or negative and false positive or negative. The degree of FDG uptake in the positive lesions was semiquantified as maximum standard uptake value (SUVmax). Results: Fifty-seven FDG PET-PET/CT exams were done in 15 patients. Seven exams were done for initial staging, 8 during and 14 after the completion of therapy, and 28 for disease surveillance. For nodal disease FDG PET-PET/CT was true positive in 8, true negative in 47 and false positive in 2 exams (sensitivity 100%, specificity 96%). For extranodal disease FDG PET-PET/CT was true positive in 6, true negative in 48 and false positive in 3 exams (sensitivity 100%, specificity 94%). The mean SUVmax for the positive nodal lesions was 15.7 (range 6.9-21.7, median 18.5) and for extranodal lesions was 14.2 (range 6.2-24.3, median 12.4). Conclusions: FDG PET-PET/CT is sensitive for the detection of viable disease in Burkitt's lymphoma. Affected areas demonstrated high degree of uptake that was reversible upon successful implementation of treatment.

  6. Head-to-head comparison between {sup 18}F-FDOPA PET/CT and MR/CT angiography in clinically recurrent head and neck paragangliomas

    Energy Technology Data Exchange (ETDEWEB)

    Heimburger, Celine; Hubele, Fabrice; Namer, Izzie Jacques [University Hospitals of Strasbourg, Department of Biophysics and Nuclear Medicine, Strasbourg (France); CNRS/University of Strasbourg, ICube, UMR 7357, Strasbourg (France); University of Strasbourg, FMTS, Faculty of Medicine, Strasbourg (France); Veillon, Francis; Riehm, Sophie; Cavalcanti, Marcela [University Hospitals of Strasbourg, Department of Radiology, Strasbourg (France); Taieb, David [Aix-Marseille University, Department of Nuclear Medicine, La Timone University Hospital, Marseille (France); Aix-Marseille University, European Center for Research in Medical Imaging, Marseille (France); Institut Paoli-Calmettes, Inserm UMR1068 Marseille Cancerology Research Center, Marseille (France); Goichot, Bernard; Chabrier, Gerard [University Hospitals of Strasbourg, Department of Internal Medicine, Strasbourg (France); Petit-Thomas, Julie; Charpiot, Anne [University Hospitals of Strasbourg, Department of Otolaryngology and Maxillofacial Surgery, Strasbourg (France); Averous, Gerlinde [University Hospitals of Strasbourg, Department of Pathology, Strasbourg (France); Imperiale, Alessio [University Hospitals of Strasbourg, Department of Biophysics and Nuclear Medicine, Strasbourg (France); CNRS/University of Strasbourg, ICube, UMR 7357, Strasbourg (France); University of Strasbourg, FMTS, Faculty of Medicine, Strasbourg (France); Hautepierre University Hospital, Biophysics and Nuclear Medicine, Strasbourg Cedex (France)

    2017-06-15

    Head and neck paragangliomas (HNPGLs) can relapse after primary treatment. Optimal imaging protocols have not yet been established for posttreatment evaluation. The aim of the present study was to assess the diagnostic value of {sup 18}F-FDOPA PET/CT and MR/CT angiography (MRA/CTA) in HNPGL patients with clinical relapse during their follow-up. Sixteen consecutive patients presenting with local pain, tinnitus, dysphagia, hoarse voice, cranial nerve involvement, deafness, or retrotympanic mass appearing during follow-up after the initial treatment of HNPGLs were retrospectively evaluated. Patients underwent both {sup 18}F-FDOPA PET/CT and MRA (15 patents) or CTA (1 patent). Both methods were first assessed under blinded conditions and afterwards correlated. Head and neck imaging abnormalities without histological confirmation were considered true-positive results based on a consensus between radiologists and nuclear physicians and on further {sup 18}F-FDOPA PET/CT and/or MRA. {sup 18}F-FDOPA PET/CT and MRA/CTA were concordant in 14 patients and in disagreement in 2 patients. {sup 18}F-FDOPA PET/CT and MRA/CTA identified, respectively, 12 and 10 presumed recurrent HNPGLs in 12 patients. The two lesions diagnosed by PET/CT only were confirmed during follow-up by otoscopic examination and MRA performed 29 and 17 months later. {sup 18}F-FDOPA PET/CT images were only slightly influenced by the posttreatment sequelae, showing a better interobserver reproducibility than MRA/CTA. Finally, in 2 of the 16 studied patients, {sup 18}F-FDOPA PET/CT detected two additional synchronous primary HNPGLs. {sup 18}F-FDOPA PET/CT is highly sensitive in posttreatment evaluation of patients with HNPGLs, and also offers better interobserver reproducibility than MRA/CTA and whole-body examination. We therefore suggest that {sup 18}F-FDOPA PET/CT is performed as the first diagnostic imaging modality in symptomatic patients with suspicion of HNPGL relapse after primary treatment when {sup 68

  7. Head-to-head comparison between "1"8F-FDOPA PET/CT and MR/CT angiography in clinically recurrent head and neck paragangliomas

    International Nuclear Information System (INIS)

    Heimburger, Celine; Hubele, Fabrice; Namer, Izzie Jacques; Veillon, Francis; Riehm, Sophie; Cavalcanti, Marcela; Taieb, David; Goichot, Bernard; Chabrier, Gerard; Petit-Thomas, Julie; Charpiot, Anne; Averous, Gerlinde; Imperiale, Alessio

    2017-01-01

    Head and neck paragangliomas (HNPGLs) can relapse after primary treatment. Optimal imaging protocols have not yet been established for posttreatment evaluation. The aim of the present study was to assess the diagnostic value of "1"8F-FDOPA PET/CT and MR/CT angiography (MRA/CTA) in HNPGL patients with clinical relapse during their follow-up. Sixteen consecutive patients presenting with local pain, tinnitus, dysphagia, hoarse voice, cranial nerve involvement, deafness, or retrotympanic mass appearing during follow-up after the initial treatment of HNPGLs were retrospectively evaluated. Patients underwent both "1"8F-FDOPA PET/CT and MRA (15 patents) or CTA (1 patent). Both methods were first assessed under blinded conditions and afterwards correlated. Head and neck imaging abnormalities without histological confirmation were considered true-positive results based on a consensus between radiologists and nuclear physicians and on further "1"8F-FDOPA PET/CT and/or MRA. "1"8F-FDOPA PET/CT and MRA/CTA were concordant in 14 patients and in disagreement in 2 patients. "1"8F-FDOPA PET/CT and MRA/CTA identified, respectively, 12 and 10 presumed recurrent HNPGLs in 12 patients. The two lesions diagnosed by PET/CT only were confirmed during follow-up by otoscopic examination and MRA performed 29 and 17 months later. "1"8F-FDOPA PET/CT images were only slightly influenced by the posttreatment sequelae, showing a better interobserver reproducibility than MRA/CTA. Finally, in 2 of the 16 studied patients, "1"8F-FDOPA PET/CT detected two additional synchronous primary HNPGLs. "1"8F-FDOPA PET/CT is highly sensitive in posttreatment evaluation of patients with HNPGLs, and also offers better interobserver reproducibility than MRA/CTA and whole-body examination. We therefore suggest that "1"8F-FDOPA PET/CT is performed as the first diagnostic imaging modality in symptomatic patients with suspicion of HNPGL relapse after primary treatment when "6"8Ga-labeled somatostatin analogues are

  8. Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

    Energy Technology Data Exchange (ETDEWEB)

    Kolb, A., E-mail: armin.kolb@med.uni-tuebingen.de; Parl, C.; Liu, C. C.; Pichler, B. J. [Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University, 72076 Tübingen (Germany); Mantlik, F. [Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University, 72076 Tübingen, Germany and Department of Empirical Inference, Max Planck Institute for Intelligent Systems, 72076 Tübingen (Germany); Lorenz, E. [Max Planck Institute for Physics, Föhringer Ring 6, 80805 München (Germany); Renker, D. [Department of Physics, Technische Universität München, 85748 Garching (Germany)

    2014-08-15

    Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90

  9. Direct comparison of [18F]MH.MZ and [18F]altanserin for 5-HT2A receptor imaging with PET

    DEFF Research Database (Denmark)

    Hansen, Hanne Demant; Ettrup, Anders; Herth, Matthias Manfred

    2013-01-01

    ]altanserin was blocked by ketanserin supporting that both radioligands bind to 5-HT(2A) receptors in the pig brain. In the HPLC analysis of pig plasma, [(18) F]MH.MZ displayed a fast and reproducible metabolism resulting in hydrophilic radiometabolites only whereas the metabolic profile of [(18) F]altanserin as expected......]altanserin were investigated in Danish Landrace pigs by brain PET scanning at baseline and after i.v. administration of blocking doses of ketanserin. Full arterial input function and HPLC analysis allowed for tissue-compartment kinetic modelling of PET data. In vitro autoradiography showed high binding...

  10. Compliance with PET acquisition protocols for therapeutic monitoring of erlotinib therapy in an international trial for patients with non-small cell lung cancer

    International Nuclear Information System (INIS)

    Binns, David S.; Callahan, Jason; Mileshkin, Linda; Pirzkall, Andrea; Yu, Wei; Fine, Bernard M.; Conti, Peter; Scott, Andrew M.; Macfarlane, David; Hicks, Rodney J.

    2011-01-01

    The Response Evaluation Criteria in Solid Tumors (RECIST) are widely used but have recognized limitations. Molecular imaging assessments, including changes in 18 F-deoxyglucose (FDG) or 18 F-deoxythymidine (FLT) uptake by positron emission tomography (PET), may provide earlier, more robust evaluation of treatment efficacy. A prospective trial evaluated on-treatment changes in FDG and FLT PET imaging among patients with relapsed or recurrent non-small cell lung cancer treated with erlotinib to assess the relationship between PET-evaluated response and clinical outcomes. We describe an audit of compliance with the study imaging charter, to establish the feasibility of achieving methodological consistency in a multicentre setting. Patients underwent PET scans at baseline and approximately day 14 and day 56 of treatment (n = 73, 66 and 51 studies, and n = 73, 63 and 50 studies for FDG PET and FLT PET, respectively). Blood glucose levels were within the target range for all FDG PET scans. Charter-specified uptake times were achieved in 86% (63/73) and 89% (65/73) of baseline FDG and FLT scans, respectively. On-treatment scans were less consistent: 72% (84/117) and 68% (77/113), respectively, achieved the target of ±5 min of baseline uptake time. However, 96% (112/117) and 94% (106/113) of FDG and FLT PET studies, respectively, were within ±15 min. Bland-Altman analysis of intra-individual hepatic average standardized uptake value (SUV ave ), to assess reproducibility, showed only a small difference in physiological uptake (-0.006 ± 0.224 in 118 follow-up FDG scans and 0.09 ± 0.81 in 111 follow-up FLT scans). It is possible to achieve high reproducibility of scan acquisition methodology, provided that strict imaging compliance guidelines are mandated in the study protocol. (orig.)

  11. Compliance with PET acquisition protocols for therapeutic monitoring of erlotinib therapy in an international trial for patients with non-small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Binns, David S.; Callahan, Jason; Mileshkin, Linda [The Peter MacCallum Cancer Centre, Melbourne (Australia); Pirzkall, Andrea; Yu, Wei; Fine, Bernard M. [Genentech, Inc., South San Francisco, CA (United States); Conti, Peter [University of Southern California Kenneth Norris Medical Center, Los Angeles, CA (United States); Scott, Andrew M. [The University of Melbourne and The Austin Hospital, Centre for PET, and Ludwig Institute for Cancer Research, Victoria (Australia); Macfarlane, David [Queensland PET Service, Royal Brisbane and Women' s Hospital, Brisbane (Australia); Hicks, Rodney J. [The University of Melbourne and The Peter MacCallum Cancer Centre, Departments of Medicine and Radiology, East Melbourne, VIC (Australia); The Peter MacCallum Cancer Centre, Melbourne (Australia)

    2011-04-15

    The Response Evaluation Criteria in Solid Tumors (RECIST) are widely used but have recognized limitations. Molecular imaging assessments, including changes in {sup 18}F-deoxyglucose (FDG) or {sup 18}F-deoxythymidine (FLT) uptake by positron emission tomography (PET), may provide earlier, more robust evaluation of treatment efficacy. A prospective trial evaluated on-treatment changes in FDG and FLT PET imaging among patients with relapsed or recurrent non-small cell lung cancer treated with erlotinib to assess the relationship between PET-evaluated response and clinical outcomes. We describe an audit of compliance with the study imaging charter, to establish the feasibility of achieving methodological consistency in a multicentre setting. Patients underwent PET scans at baseline and approximately day 14 and day 56 of treatment (n = 73, 66 and 51 studies, and n = 73, 63 and 50 studies for FDG PET and FLT PET, respectively). Blood glucose levels were within the target range for all FDG PET scans. Charter-specified uptake times were achieved in 86% (63/73) and 89% (65/73) of baseline FDG and FLT scans, respectively. On-treatment scans were less consistent: 72% (84/117) and 68% (77/113), respectively, achieved the target of {+-}5 min of baseline uptake time. However, 96% (112/117) and 94% (106/113) of FDG and FLT PET studies, respectively, were within {+-}15 min. Bland-Altman analysis of intra-individual hepatic average standardized uptake value (SUV{sub ave}), to assess reproducibility, showed only a small difference in physiological uptake (-0.006 {+-} 0.224 in 118 follow-up FDG scans and 0.09 {+-} 0.81 in 111 follow-up FLT scans). It is possible to achieve high reproducibility of scan acquisition methodology, provided that strict imaging compliance guidelines are mandated in the study protocol. (orig.)

  12. Highly conductive and low cost Ni-PET flexible substrate for efficient dye-sensitized solar cells.

    Science.gov (United States)

    Su, Haijun; Zhang, Mingyang; Chang, Ya-Huei; Zhai, Peng; Hau, Nga Yu; Huang, Yu-Ting; Liu, Chang; Soh, Ai Kah; Feng, Shien-Ping

    2014-04-23

    The highly conductive and flexible nickel-polyethylene terephthalate (Ni-PET) substrate was prepared by a facile way including electrodeposition and hot-press transferring. The effectiveness was demonstrated in the counter electrode of dye-sensitized solar cells (DSSCs). The Ni film electrodeposition mechanism, microstructure, and DSSC performance for the Ni-PET flexible substrate were investigated. The uniform and continuous Ni film was first fabricated by electroplating metallic Ni on fluorine-doped tin oxide (FTO) and then intactly transferred onto PET via hot-pressing using Surlyn as the joint adhesive. The obtained flexible Ni-PET substrate shows low sheet resistance of 0.18Ω/□ and good chemical stability for the I(-)/I(3-) electrolyte. A high light-to-electric energy conversion efficiency of 7.89% was demonstrated in DSSCs system based on this flexible electrode substrate due to its high conductivity, which presents an improvement of 10.4% as compared with the general ITO-PEN flexible substrate. This method paves a facile and cost-effective way to manufacture various metals on a plastic nonconducive substrate beneficial for the devices toward flexible and rollable.

  13. FDG-PET status following chemoradiotherapy provides high management impact and powerful prognostic stratification in oesophageal cancer

    International Nuclear Information System (INIS)

    Duong, Cuong P.; Thomas, Robert J.S.; Hicks, Rodney J.; Drummond, Elizabeth; Weih, LeAnn; Leong, Trevor; Michael, Michael

    2006-01-01

    The purpose of this study was to evaluate the impact of FDG-PET following chemoradiotherapy (CRT) on treatment planning and survival in patients with oesophageal cancer (OC). Fifty-three consecutive OC patients had a post-treatment PET scan to evaluate tumour response to CRT prior to possible surgery. Baseline pre-CRT PET was performed in 33 patients. Prospectively recorded post-CRT management plans were compared with post-PET treatment. High impact was defined as a change in treatment intent or modality. Survival was analysed using the Kaplan-Meier product limit method and Cox proportional hazards regression model. After completion of CRT, 23/53 patients (43%) achieved complete metabolic response (CMR), as compared with only four (8%) with complete response on computed tomography. High PET impact was observed in 19 patients (36%). CMR was strongly predictive of survival (p<0.008) on multivariate analysis. CMR patients in whom resection was not performed had comparable survival to those (CMR and non-CMR) who underwent resection. The use of post-treatment FDG-PET for assessment of tumour response after CRT changed the clinical management of more than one-third of OC patients. CMR status as assessed by PET powerfully stratified prognosis. Even in the absence of a baseline study, normalisation of uptake at all sites of known tumoral involvement carries a good medium-term prognosis. (orig.)

  14. Dedicated brain PET system of PET/MR for brain research

    International Nuclear Information System (INIS)

    Cheng, Li; Liu, Yaqiang; Ma, Tianyu; Wang, Shi; Wei, Qingyang; Xu, Tianpeng

    2015-01-01

    This work is to replace PET ring in human brain PET/MR system with a dedicated wearable PET insert, aimed at improving both patient feasibility and system performance for brain imaging. The designed PET/MR system includes two parts: the inside parts, including a radio frequency (RF) coil and PET ring, are mounted on patient’s head, and the outside part, a MR imager, is dependent of patient. The RF coil is the innermost layer, surrounded by an outer PET-ring layer. They are supported by a MRcompatible structure. And both RF coil and PET detectors are placed inside a standard clinical 3-T MR imager. From the design of the system we can infer that some advantages can be achieved. First, high sensitivity will be achieved with the same amount crystals as the PET ring is more close to region-of-interest area, at a reduced cost. Second, by using a 2-layer depth of interaction (DOI) detector, the parallax effect can be minimized. The resolution will benefit from short positron range caused by magnetic field and smaller ring diameter will also reduce the effect of non-collinearity. Thirdly, as the PET ring is mounted on head, impact of patient motion will be reduced.

  15. Dedicated brain PET system of PET/MR for brain research

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Li; Liu, Yaqiang; Ma, Tianyu; Wang, Shi; Wei, Qingyang; Xu, Tianpeng [Institute of Medical Physics, Department of Engineering Physics, Tsinghua University, Beijing (China)

    2015-05-18

    This work is to replace PET ring in human brain PET/MR system with a dedicated wearable PET insert, aimed at improving both patient feasibility and system performance for brain imaging. The designed PET/MR system includes two parts: the inside parts, including a radio frequency (RF) coil and PET ring, are mounted on patient’s head, and the outside part, a MR imager, is dependent of patient. The RF coil is the innermost layer, surrounded by an outer PET-ring layer. They are supported by a MRcompatible structure. And both RF coil and PET detectors are placed inside a standard clinical 3-T MR imager. From the design of the system we can infer that some advantages can be achieved. First, high sensitivity will be achieved with the same amount crystals as the PET ring is more close to region-of-interest area, at a reduced cost. Second, by using a 2-layer depth of interaction (DOI) detector, the parallax effect can be minimized. The resolution will benefit from short positron range caused by magnetic field and smaller ring diameter will also reduce the effect of non-collinearity. Thirdly, as the PET ring is mounted on head, impact of patient motion will be reduced.

  16. Evaluation of the PET component of simultaneous [18F]choline PET/MRI in prostate cancer: comparison with [18F]choline PET/CT

    International Nuclear Information System (INIS)

    Wetter, Axel; Lipponer, Christine; Nensa, Felix; Altenbernd, Jens-Christian; Schlosser, Thomas; Lauenstein, Thomas; Heusch, Philipp; Ruebben, Herbert; Bockisch, Andreas; Poeppel, Thorsten; Nagarajah, James

    2014-01-01

    The aim of this study was to evaluate the positron emission tomography (PET) component of [ 18 F]choline PET/MRI and compare it with the PET component of [ 18 F]choline PET/CT in patients with histologically proven prostate cancer and suspected recurrent prostate cancer. Thirty-six patients were examined with simultaneous [ 18 F]choline PET/MRI following combined [ 18 F]choline PET/CT. Fifty-eight PET-positive lesions in PET/CT and PET/MRI were evaluated by measuring the maximum and mean standardized uptake values (SUV max and SUV mean ) using volume of interest (VOI) analysis. A scoring system was applied to determine the quality of the PET images of both PET/CT and PET/MRI. Agreement between PET/CT and PET/MRI regarding SUV max and SUV mean was tested using Pearson's product-moment correlation and Bland-Altman analysis. All PET-positive lesions that were visible on PET/CT were also detectable on PET/MRI. The quality of the PET images was comparable in both groups. Median SUV max and SUV mean of all lesions were significantly lower in PET/MRI than in PET/CT (5.2 vs 6.1, p max of PET/CT and PET/MRI (R = 0.86, p mean of PET/CT and PET/MRI (R = 0.81, p max of PET/CT vs PET/MRI and -1.12 to +2.23 between SUV mean of PET/CT vs PET/MRI. PET image quality of PET/MRI was comparable to that of PET/CT. A highly significant correlation between SUV max and SUV mean was found. Both SUV max and SUV mean were significantly lower in [ 18 F]choline PET/MRI than in [ 18 F]choline PET/CT. Differences of SUV max and SUV mean might be caused by different techniques of attenuation correction. Furthermore, differences in biodistribution and biokinetics of [ 18 F]choline between the subsequent examinations and in the respective organ systems have to be taken into account. (orig.)

  17. A multi-atlas based method for automated anatomical Macaca fascicularis brain MRI segmentation and PET kinetic extraction.

    Science.gov (United States)

    Ballanger, Bénédicte; Tremblay, Léon; Sgambato-Faure, Véronique; Beaudoin-Gobert, Maude; Lavenne, Franck; Le Bars, Didier; Costes, Nicolas

    2013-08-15

    MRI templates and digital atlases are needed for automated and reproducible quantitative analysis of non-human primate PET studies. Segmenting brain images via multiple atlases outperforms single-atlas labelling in humans. We present a set of atlases manually delineated on brain MRI scans of the monkey Macaca fascicularis. We use this multi-atlas dataset to evaluate two automated methods in terms of accuracy, robustness and reliability in segmenting brain structures on MRI and extracting regional PET measures. Twelve individual Macaca fascicularis high-resolution 3DT1 MR images were acquired. Four individual atlases were created by manually drawing 42 anatomical structures, including cortical and sub-cortical structures, white matter regions, and ventricles. To create the MRI template, we first chose one MRI to define a reference space, and then performed a two-step iterative procedure: affine registration of individual MRIs to the reference MRI, followed by averaging of the twelve resampled MRIs. Automated segmentation in native space was obtained in two ways: 1) Maximum probability atlases were created by decision fusion of two to four individual atlases in the reference space, and transformation back into the individual native space (MAXPROB)(.) 2) One to four individual atlases were registered directly to the individual native space, and combined by decision fusion (PROPAG). Accuracy was evaluated by computing the Dice similarity index and the volume difference. The robustness and reproducibility of PET regional measurements obtained via automated segmentation was evaluated on four co-registered MRI/PET datasets, which included test-retest data. Dice indices were always over 0.7 and reached maximal values of 0.9 for PROPAG with all four individual atlases. There was no significant mean volume bias. The standard deviation of the bias decreased significantly when increasing the number of individual atlases. MAXPROB performed better when increasing the number of

  18. Guidance for reading FDG PET scans in dementia patients

    International Nuclear Information System (INIS)

    Herholz, K.

    2014-01-01

    18F-2-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) is a powerful method for detection of disease-related impairment of cerebral glucose metabolism in neuro degenerative diseases. It is of particular interest for early and differential diagnosis of dementia. Reading FDG PET scans requires training to recognise deviations from normal functional brain anatomy and its variations. This paper provides guidance for displaying FDG PET brain scans in a reproducible manner that allows reliable recognition of characteristic disease-related metabolic changes. It also describes typical findings in Alzheimer’s disease, Frontotemporal Dementia and Dementia with Lewy Bodies and possible confounding factors, such as vascular changes and brain atrophy. It provides a brief overview on findings in other neuro degenerative diseases and addresses the potential and limitations of software packages for comparison of individual scans with reference data.

  19. Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe

    Science.gov (United States)

    Majewski, Stanislaw; Proffitt, James

    2010-12-28

    A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.

  20. Feasibility of a semi-automated contrast-oriented algorithm for tumor segmentation in retrospectively gated PET images: phantom and clinical validation

    Science.gov (United States)

    Carles, Montserrat; Fechter, Tobias; Nemer, Ursula; Nanko, Norbert; Mix, Michael; Nestle, Ursula; Schaefer, Andrea

    2015-12-01

    PET/CT plays an important role in radiotherapy planning for lung tumors. Several segmentation algorithms have been proposed for PET tumor segmentation. However, most of them do not take into account respiratory motion and are not well validated. The aim of this work was to evaluate a semi-automated contrast-oriented algorithm (COA) for PET tumor segmentation adapted to retrospectively gated (4D) images. The evaluation involved a wide set of 4D-PET/CT acquisitions of dynamic experimental phantoms and lung cancer patients. In addition, segmentation accuracy of 4D-COA was compared with four other state-of-the-art algorithms. In phantom evaluation, the physical properties of the objects defined the gold standard. In clinical evaluation, the ground truth was estimated by the STAPLE (Simultaneous Truth and Performance Level Estimation) consensus of three manual PET contours by experts. Algorithm evaluation with phantoms resulted in: (i) no statistically significant diameter differences for different targets and movements (Δ φ =0.3+/- 1.6 mm); (ii) reproducibility for heterogeneous and irregular targets independent of user initial interaction and (iii) good segmentation agreement for irregular targets compared to manual CT delineation in terms of Dice Similarity Coefficient (DSC  =  0.66+/- 0.04 ), Positive Predictive Value (PPV  =  0.81+/- 0.06 ) and Sensitivity (Sen.  =  0.49+/- 0.05 ). In clinical evaluation, the segmented volume was in reasonable agreement with the consensus volume (difference in volume (%Vol)  =  40+/- 30 , DSC  =  0.71+/- 0.07 and PPV  =  0.90+/- 0.13 ). High accuracy in target tracking position (Δ ME) was obtained for experimental and clinical data (Δ ME{{}\\text{exp}}=0+/- 3 mm; Δ ME{{}\\text{clin}}=0.3+/- 1.4 mm). In the comparison with other lung segmentation methods, 4D-COA has shown the highest volume accuracy in both experimental and clinical data. In conclusion, the accuracy in volume

  1. Markerless 3D Head Tracking for Motion Correction in High Resolution PET Brain Imaging

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter

    relying on markers. Data-driven motion correction is problematic due to the physiological dynamics. Marker-based tracking is potentially unreliable, and it is extremely hard to validate when the tracking information is correct. The motion estimation is essential for proper motion correction of the PET......This thesis concerns application specific 3D head tracking. The purpose is to improve motion correction in position emission tomography (PET) brain imaging through development of markerless tracking. Currently, motion correction strategies are based on either the PET data itself or tracking devices...... images. Incorrect motion correction can in the worst cases result in wrong diagnosis or treatment. The evolution of a markerless custom-made structured light 3D surface tracking system is presented. The system is targeted at state-of-the-art high resolution dedicated brain PET scanners with a resolution...

  2. The motivations and methodology for high-throughput PET imaging of small animals in cancer research

    Energy Technology Data Exchange (ETDEWEB)

    Aide, Nicolas [Francois Baclesse Cancer Centre, Nuclear Medicine Department, Caen Cedex (France); Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Visser, Eric P. [Radboud University Nijmegen Medical Center, Nuclear Medicine Department, Nijmegen (Netherlands); Lheureux, Stephanie [Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Heutte, Natacha [Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Szanda, Istvan [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Hicks, Rodney J. [Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne (Australia)

    2012-09-15

    Over the last decade, small-animal PET imaging has become a vital platform technology in cancer research. With the development of molecularly targeted therapies and drug combinations requiring evaluation of different schedules, the number of animals to be imaged within a PET experiment has increased. This paper describes experimental design requirements to reach statistical significance, based on the expected change in tracer uptake in treated animals as compared to the control group, the number of groups that will be imaged, and the expected intra-animal variability for a given tracer. We also review how high-throughput studies can be performed in dedicated small-animal PET, high-resolution clinical PET systems and planar positron imaging systems by imaging more than one animal simultaneously. Customized beds designed to image more than one animal in large-bore small-animal PET scanners are described. Physics issues related to the presence of several rodents within the field of view (i.e. deterioration of spatial resolution and sensitivity as the radial and the axial offsets increase, respectively, as well as a larger effect of attenuation and the number of scatter events), which can be assessed by using the NEMA NU 4 image quality phantom, are detailed. (orig.)

  3. PetIGA-MF: a multi-field high-performance toolbox for structure-preserving B-splines spaces

    KAUST Repository

    Sarmiento, Adel

    2016-10-01

    We describe a high-performance solution framework for isogeometric discrete differential forms based on B-splines: PetIGA-MF. Built on top of PetIGA, an open-source library we have built and developed over the last decade, PetIGA-MF is a general multi-field discretization tool. To test the capabilities of our implementation, we solve different viscous flow problems such as Darcy, Stokes, Brinkman, and Navier-Stokes equations. Several convergence benchmarks based on manufactured solutions are presented assuring optimal convergence rates of the approximations, showing the accuracy and robustness of our solver.

  4. Development of dose delivery verification by PET imaging of photonuclear reactions following high energy photon therapy

    International Nuclear Information System (INIS)

    Janek, S; Svensson, R; Jonsson, C; Brahme, A

    2006-01-01

    A method for dose delivery monitoring after high energy photon therapy has been investigated based on positron emission tomography (PET). The technique is based on the activation of body tissues by high energy bremsstrahlung beams, preferably with energies well above 20 MeV, resulting primarily in 11 C and 15 O but also 13 N, all positron-emitting radionuclides produced by photoneutron reactions in the nuclei of 12 C, 16 O and 14 N. A PMMA phantom and animal tissue, a frozen hind leg of a pig, were irradiated to 10 Gy and the induced positron activity distributions were measured off-line in a PET camera a couple of minutes after irradiation. The accelerator used was a Racetrack Microtron at the Karolinska University Hospital using 50 MV scanned photon beams. From photonuclear cross-section data integrated over the 50 MV photon fluence spectrum the predicted PET signal was calculated and compared with experimental measurements. Since measured PET images change with time post irradiation, as a result of the different decay times of the radionuclides, the signals from activated 12 C, 16 O and 14 N within the irradiated volume could be separated from each other. Most information is obtained from the carbon and oxygen radionuclides which are the most abundant elements in soft tissue. The predicted and measured overall positron activities are almost equal (-3%) while the predicted activity originating from nitrogen is overestimated by almost a factor of two, possibly due to experimental noise. Based on the results obtained in this first feasibility study the great value of a combined radiotherapy-PET-CT unit is indicated in order to fully exploit the high activity signal from oxygen immediately after treatment and to avoid patient repositioning. With an RT-PET-CT unit a high signal could be collected even at a dose level of 2 Gy and the acquisition time for the PET could be reduced considerably. Real patient dose delivery verification by means of PET imaging seems to be

  5. [18F]FDG PET/CT outperforms [18F]FDG PET/MRI in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Vrachimis, Alexis; Wenning, Christian; Weckesser, Matthias; Stegger, Lars; Burg, Matthias Christian; Allkemper, Thomas; Schaefers, Michael

    2016-01-01

    To evaluate the diagnostic potential of PET/MRI with [ 18 F]FDG in comparison to PET/CT in patients with differentiated thyroid cancer suspected or known to have dedifferentiated. The study included 31 thyroidectomized and remnant-ablated patients who underwent a scheduled [ 18 F]FDG PET/CT scan and were then enrolled for a PET/MRI scan of the neck and thorax. The datasets (PET/CT, PET/MRI) were rated regarding lesion count, conspicuity, diameter and characterization. Standardized uptake values were determined for all [ 18 F]FDG-positive lesions. Histology, cytology, and examinations before and after treatment served as the standards of reference. Of 26 patients with a dedifferentiated tumour burden, 25 were correctly identified by both [ 18 F]FDG PET/CT and PET/MRI. Detection rates by PET/CT and PET/MRI were 97 % (113 of 116 lesions) and 85 % (99 of 113 lesions) for malignant lesions, and 100 % (48 of 48 lesions) and 77 % (37 of 48 lesions) for benign lesions, respectively. Lesion conspicuity was higher on PET/CT for both malignant and benign pulmonary lesions and in the overall rating for malignant lesions (p < 0.001). There was a difference between PET/CT and PET/MRI in overall evaluation of malignant lesions (p < 0.01) and detection of pulmonary metastases (p < 0.001). Surgical evaluation revealed three malignant lesions missed by both modalities. PET/MRI additionally failed to detect 14 pulmonary metastases and 11 benign lesions. In patients with thyroid cancer and suspected or known dedifferentiation, [ 18 F]FDG PET/MRI was inferior to low-dose [ 18 F]FDG PET/CT for the assessment of pulmonary status. However, for the assessment of cervical status, [ 18 F]FDG PET/MRI was equal to contrast-enhanced neck [ 18 F]FDG PET/CT. Therefore, [ 18 F]FDG PET/MRI combined with a low-dose CT scan of the thorax may provide an imaging solution when high-quality imaging is needed and high-energy CT is undesirable or the use of a contrast agent is contraindicated. (orig.)

  6. Impact of consensus contours from multiple PET segmentation methods on the accuracy of functional volume delineation

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, A. [Saarland University Medical Centre, Department of Nuclear Medicine, Homburg (Germany); Vermandel, M. [U1189 - ONCO-THAI - Image Assisted Laser Therapy for Oncology, University of Lille, Inserm, CHU Lille, Lille (France); CHU Lille, Nuclear Medicine Department, Lille (France); Baillet, C. [CHU Lille, Nuclear Medicine Department, Lille (France); Dewalle-Vignion, A.S. [U1189 - ONCO-THAI - Image Assisted Laser Therapy for Oncology, University of Lille, Inserm, CHU Lille, Lille (France); Modzelewski, R.; Vera, P.; Gardin, I. [Centre Henri-Becquerel and LITIS EA4108, Rouen (France); Massoptier, L.; Parcq, C.; Gibon, D. [AQUILAB, Research and Innovation Department, Loos Les Lille (France); Fechter, T.; Nestle, U. [University Medical Center Freiburg, Department for Radiation Oncology, Freiburg (Germany); German Cancer Consortium (DKTK) Freiburg and German Cancer Research Center (DKFZ), Heidelberg (Germany); Nemer, U. [University Medical Center Freiburg, Department of Nuclear Medicine, Freiburg (Germany)

    2016-05-15

    The aim of this study was to evaluate the impact of consensus algorithms on segmentation results when applied to clinical PET images. In particular, whether the use of the majority vote or STAPLE algorithm could improve the accuracy and reproducibility of the segmentation provided by the combination of three semiautomatic segmentation algorithms was investigated. Three published segmentation methods (contrast-oriented, possibility theory and adaptive thresholding) and two consensus algorithms (majority vote and STAPLE) were implemented in a single software platform (Artiview registered). Four clinical datasets including different locations (thorax, breast, abdomen) or pathologies (primary NSCLC tumours, metastasis, lymphoma) were used to evaluate accuracy and reproducibility of the consensus approach in comparison with pathology as the ground truth or CT as a ground truth surrogate. Variability in the performance of the individual segmentation algorithms for lesions of different tumour entities reflected the variability in PET images in terms of resolution, contrast and noise. Independent of location and pathology of the lesion, however, the consensus method resulted in improved accuracy in volume segmentation compared with the worst-performing individual method in the majority of cases and was close to the best-performing method in many cases. In addition, the implementation revealed high reproducibility in the segmentation results with small changes in the respective starting conditions. There were no significant differences in the results with the STAPLE algorithm and the majority vote algorithm. This study showed that combining different PET segmentation methods by the use of a consensus algorithm offers robustness against the variable performance of individual segmentation methods and this approach would therefore be useful in radiation oncology. It might also be relevant for other scenarios such as the merging of expert recommendations in clinical routine and

  7. Highly improved operation of monolithic BGO-PET blocks

    Science.gov (United States)

    Gonzalez-Montoro, A.; Sanchez, F.; Majewski, S.; Zanettini, S.; Benlloch, J. M.; Gonzalez, A. J.

    2017-11-01

    In PET scanners both scintillation crystals and photosensors are key components defining the system's performance and cost. Original PET systems used BGO or NaI(Tl) scintillators but achieved limited performance due to its slow decay and relatively low light output. Moreover, NaI(Tl) has low stopping power for 511 keV annihilation photons. In this study we report the possibility to reintroduce BGO crystals, and in particular in the form of monolithic blocks, especially suitable for low-dose large-size PET scanners, offering significantly improved sensitivity at a highly reduced cost compared to LYSO type fast scintillators. We have studied the performance of a monolithic BGO block as large as 50 × 50 × 15 mm3 with black-painted lateral walls to reduce lights spread, enabling accurate photon depth of interaction (DOI) measurements. A directional optical layer, called retro-reflector, was coupled to the entrance face bouncing back the scintillation light in the direction of the emission source and, therefore, adding to the light signal while preserving the narrow light cone distribution. Four configurations namely 12 × 12 and 16 × 16 SiPM arrays (3 mm × 3 mm each) as photosensors, with or without a nanopattern treatment at the crystal exit face, have been studied. This structure consisted of a thin layer of a specific high refractive index material shaped with a periodic nanopattern, increasing the scintillation light extraction. The readout returned information for each SiPM row and column, characterizing the X-Y light distribution projections. We have studied the detector spatial resolution using collimated 22Na sources at normal incidence. The DOI resolution was evaluated using collimated gamma beams with lateral incidence. The overall best detector performance was obtained for the 16× 16 SiPM array offering higher readout granularity. We have determined the spatial resolution for 3 separated DOI layers, obtaining the best results for the DOI region near to

  8. Repeatability of regional myocardial blood flow calculation in 82Rb PET imaging

    International Nuclear Information System (INIS)

    Knešaurek, Karin; Machac, Josef; Zhang, Zhuangyu

    2009-01-01

    We evaluated the repeatability of the calculation of myocardial blood flow (MBF) at rest and pharmacological stress, and calculated the coronary flow reserve (CFR) utilizing 82 Rb PET imaging. The aim of the research was to prove high repeatability for global MBF and CFR values and good repeatability for regional MBF and CFR values. The results will have significant impact on cardiac PET imaging in terms of making it more affordable and increasing its use. 12 normal volunteers were imaged at rest and during pharmacological stress, with 2220 MBq of 82 Rb each. A GE Advance PET system was used to acquire dynamic 50-frame studies. MBF was calculated with a 2-compartmental model using a modified PMOD program (PMOD; University Hospital Zurich, Zurich, Switzerland). Two differential equations, describing a 2-compartmental model, were solved by numerical integration and using Levenberg-Marquardt's method for fitting data. The PMOD program defines 16 standard segments and calculates myocardial flow for each segment, as well as average septal, anterior, lateral, inferior and global flow. Repeatability was evaluated according to the method of Bland and Altman. Global rest and stress MBF, as well as global CFR, showed very good repeatability. No significant differences were found between the paired resting global MBF (0.63 ± 0.13 vs. 0.64 ± 0.13 mL/min/g; mean difference, -1.0% ± 2.6%) and the stress global MBF (1.37 ± 0.23 vs. 1.37 ± 0.24; mean difference, 0.1% ± 2.3%). Global CFR was highly reproducible (2.25 ± 0.56 vs. 2.22 ± 0.54, P = not statistically significant; mean difference, 1.3% ± 14.3%). Repeatability coefficients for global rest MBF were 0.033 (5.2%) and stress MBF 0.062 (4.5%) mL/min/g. Regional rest and stress MBF and CFR have shown good reproducibility. The average per sector repeatability coefficients for rest MBF were 0.056 (8.5%) and stress MBF 0.089 (6.3%) mL/min/g, and average repeatability coefficient for CFR was 0.25 (10.6%). The results

  9. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    International Nuclear Information System (INIS)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah

    2014-01-01

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after 18 F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced PET

  10. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah [Yeungnam Univ. Hospital, Daegu (Korea, Republic of)

    2014-03-15

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after {sup 18}F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast

  11. Development of a nomogram combining clinical staging with 18F-FDG PET/CT image features in non-small-cell lung cancer stage I-III

    International Nuclear Information System (INIS)

    Desseroit, Marie-Charlotte; Visvikis, Dimitris; Majdoub, Mohamed; Hatt, Mathieu; Tixier, Florent; Perdrisot, Remy; Cheze Le Rest, Catherine; Guillevin, Remy

    2016-01-01

    Our goal was to develop a nomogram by exploiting intratumour heterogeneity on CT and PET images from routine 18 F-FDG PET/CT acquisitions to identify patients with the poorest prognosis. This retrospective study included 116 patients with NSCLC stage I, II or III and with staging 18 F-FDG PET/CT imaging. Primary tumour volumes were delineated using the FLAB algorithm and 3D Slicer trademark on PET and CT images, respectively. PET and CT heterogeneities were quantified using texture analysis. The reproducibility of the CT features was assessed on a separate test-retest dataset. The stratification power of the PET/CT features was evaluated using the Kaplan-Meier method and the log-rank test. The best standard metric (functional volume) was combined with the least redundant and most prognostic PET/CT heterogeneity features to build the nomogram. PET entropy and CT zone percentage had the highest complementary values with clinical stage and functional volume. The nomogram improved stratification amongst patients with stage II and III disease, allowing identification of patients with the poorest prognosis (clinical stage III, large tumour volume, high PET heterogeneity and low CT heterogeneity). Intratumour heterogeneity quantified using textural features on both CT and PET images from routine staging 18 F-FDG PET/CT acquisitions can be used to create a nomogram with higher stratification power than staging alone. (orig.)

  12. The upcycling of post-industrial PP/PET waste streams through in-situ microfibrillar preparation

    International Nuclear Information System (INIS)

    Delva, Laurens; Ragaert, Kim; Cardon, Ludwig

    2015-01-01

    Post-industrial plastic waste streams can be re-used as secondary material streams for polymer processing by extrusion or injection moulding. One of the major commercially available waste stream contains polypropylene (PP) contaminated with polyesters (mostly polyethylene tereftalate - PET). An important practical hurdle for the direct implementation of this waste stream is the immiscibility of PP and PET in the melt, which leads to segregation within the polymer structure and adversely affects the reproducibility and mechanical properties of the manufactured parts. It has been indicated in literature that the creation of PET microfibrils in the PP matrix could undo these drawbacks and upcycle the PP/PET combination. Within the current research, a commercially available virgin PP/PET was evaluated for the microfibrillar preparation. The mechanical (tensile and impact) properties, thermal properties and morphology of the composites were characterized at different stages of the microfibrillar preparation

  13. The upcycling of post-industrial PP/PET waste streams through in-situ microfibrillar preparation

    Energy Technology Data Exchange (ETDEWEB)

    Delva, Laurens, E-mail: Laurens.Delva@ugent.be; Ragaert, Kim, E-mail: Kim.Ragaert@ugent.be; Cardon, Ludwig, E-mail: Ludwig.Cardon@ugent.be [Centre for Polymer and Materials Technologies (CPMT), Department of Materials Science and Engineering, Ghent University, Technologiepark 915, 9052 Zwijnaarde (Belgium)

    2015-12-17

    Post-industrial plastic waste streams can be re-used as secondary material streams for polymer processing by extrusion or injection moulding. One of the major commercially available waste stream contains polypropylene (PP) contaminated with polyesters (mostly polyethylene tereftalate - PET). An important practical hurdle for the direct implementation of this waste stream is the immiscibility of PP and PET in the melt, which leads to segregation within the polymer structure and adversely affects the reproducibility and mechanical properties of the manufactured parts. It has been indicated in literature that the creation of PET microfibrils in the PP matrix could undo these drawbacks and upcycle the PP/PET combination. Within the current research, a commercially available virgin PP/PET was evaluated for the microfibrillar preparation. The mechanical (tensile and impact) properties, thermal properties and morphology of the composites were characterized at different stages of the microfibrillar preparation.

  14. The upcycling of post-industrial PP/PET waste streams through in-situ microfibrillar preparation

    Science.gov (United States)

    Delva, Laurens; Ragaert, Kim; Cardon, Ludwig

    2015-12-01

    Post-industrial plastic waste streams can be re-used as secondary material streams for polymer processing by extrusion or injection moulding. One of the major commercially available waste stream contains polypropylene (PP) contaminated with polyesters (mostly polyethylene tereftalate - PET). An important practical hurdle for the direct implementation of this waste stream is the immiscibility of PP and PET in the melt, which leads to segregation within the polymer structure and adversely affects the reproducibility and mechanical properties of the manufactured parts. It has been indicated in literature that the creation of PET microfibrils in the PP matrix could undo these drawbacks and upcycle the PP/PET combination. Within the current research, a commercially available virgin PP/PET was evaluated for the microfibrillar preparation. The mechanical (tensile and impact) properties, thermal properties and morphology of the composites were characterized at different stages of the microfibrillar preparation.

  15. A Study on the Basic Criteria for Selecting Heterogeneity Parameters of F18-FDG PET Images.

    Directory of Open Access Journals (Sweden)

    Attila Forgacs

    Full Text Available Textural analysis might give new insights into the quantitative characterization of metabolically active tumors. More than thirty textural parameters have been investigated in former F18-FDG studies already. The purpose of the paper is to declare basic requirements as a selection strategy to identify the most appropriate heterogeneity parameters to measure textural features. Our predefined requirements were: a reliable heterogeneity parameter has to be volume independent, reproducible, and suitable for expressing quantitatively the degree of heterogeneity. Based on this criteria, we compared various suggested measures of homogeneity. A homogeneous cylindrical phantom was measured on three different PET/CT scanners using the commonly used protocol. In addition, a custom-made inhomogeneous tumor insert placed into the NEMA image quality phantom was imaged with a set of acquisition times and several different reconstruction protocols. PET data of 65 patients with proven lung lesions were retrospectively analyzed as well. Four heterogeneity parameters out of 27 were found as the most attractive ones to characterize the textural properties of metabolically active tumors in FDG PET images. These four parameters included Entropy, Contrast, Correlation, and Coefficient of Variation. These parameters were independent of delineated tumor volume (bigger than 25-30 ml, provided reproducible values (relative standard deviation< 10%, and showed high sensitivity to changes in heterogeneity. Phantom measurements are a viable way to test the reliability of heterogeneity parameters that would be of interest to nuclear imaging clinicians.

  16. A Study on the Basic Criteria for Selecting Heterogeneity Parameters of F18-FDG PET Images

    Science.gov (United States)

    Forgacs, Attila; Pall Jonsson, Hermann; Dahlbom, Magnus; Daver, Freddie; D. DiFranco, Matthew; Opposits, Gabor; K. Krizsan, Aron; Garai, Ildiko; Czernin, Johannes; Varga, Jozsef; Tron, Lajos; Balkay, Laszlo

    2016-01-01

    Textural analysis might give new insights into the quantitative characterization of metabolically active tumors. More than thirty textural parameters have been investigated in former F18-FDG studies already. The purpose of the paper is to declare basic requirements as a selection strategy to identify the most appropriate heterogeneity parameters to measure textural features. Our predefined requirements were: a reliable heterogeneity parameter has to be volume independent, reproducible, and suitable for expressing quantitatively the degree of heterogeneity. Based on this criteria, we compared various suggested measures of homogeneity. A homogeneous cylindrical phantom was measured on three different PET/CT scanners using the commonly used protocol. In addition, a custom-made inhomogeneous tumor insert placed into the NEMA image quality phantom was imaged with a set of acquisition times and several different reconstruction protocols. PET data of 65 patients with proven lung lesions were retrospectively analyzed as well. Four heterogeneity parameters out of 27 were found as the most attractive ones to characterize the textural properties of metabolically active tumors in FDG PET images. These four parameters included Entropy, Contrast, Correlation, and Coefficient of Variation. These parameters were independent of delineated tumor volume (bigger than 25–30 ml), provided reproducible values (relative standard deviation< 10%), and showed high sensitivity to changes in heterogeneity. Phantom measurements are a viable way to test the reliability of heterogeneity parameters that would be of interest to nuclear imaging clinicians. PMID:27736888

  17. Validating PET segmentation of thoracic lesions-is 4D PET necessary?

    DEFF Research Database (Denmark)

    Nielsen, M. S.; Carl, J.

    2017-01-01

    Respiratory-induced motions are prone to degrade the positron emission tomography (PET) signal with the consequent loss of image information and unreliable segmentations. This phantom study aims to assess the discrepancies relative to stationary PET segmentations, of widely used semiautomatic PET...... segmentation methods on heterogeneous target lesions influenced by motion during image acquisition. Three target lesions included dual F-18 Fluoro-deoxy-glucose (FDG) tracer concentrations as high-and low tracer activities relative to the background. Four different tracer concentration arrangements were...... segmented using three SUV threshold methods (Max40%, SUV40% and 2.5SUV) and a gradient based method (GradientSeg). Segmentations in static 3D-PET scans (PETsta) specified the reference conditions for the individual segmentation methods, target lesions and tracer concentrations. The motion included PET...

  18. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  19. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    Science.gov (United States)

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  20. A high resolution TOF-PET concept with axial geometry and digital SiPM readout

    CERN Document Server

    Casella, C; Joram, C; Schneider, T

    2014-01-01

    The axial arrangement of long scintillation crystals is a promising concept in PET instrumentation to address the need for optimized resolution and sensitivity. Individual crystal readout and arrays of wavelength shifter strips placed orthogonally to the crystals lead to a 3D-detection of the annihilations photons. A fully operational demonstrator scanner, developed by the AX-PET collaboration, proved the potential of this concept in terms of energy and spatial resolution as well as sensitivity. This paper describes a feasibility study, performed on axial prototype detector modules with 100 mm long LYSO crystals, read out by the novel digital Silicon Photomultipliers (dSiPM) from Philips. With their highly integrated readout electronics and excellent intrinsic time resolution, dSiPMs allow for compact, axial detector modules which may extend the potential of the axial PET concept by time of fl ight capabilities (TOF-PET). A coincidence time resolution of 211 ps (FWHM) was achieved in the coincidence of two ax...

  1. The effect of intravenous contrast on SUV value in 18F-FDG PET/CT using diagnostic high energy CT

    International Nuclear Information System (INIS)

    Jeong, Young Jin; Kang, Do Young

    2006-01-01

    According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT - 120 kVp, 130 mAs) scan. Than contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET emission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in all patients. Also pathologic lesions were investigated. There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p < 0.001). The maxSUV was 1.1 ± 0.5 in PET images with CECT-corrected attenuation and 1.0 ± 0.5 in PET images with NCCT-corrected attenuation. The limit of agreement was 0.1 ± 0.3 in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 and segment 8 of the liver and spleen (p <0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p < 0.001). The maxSUV was 4.7 ± 2.0 in PET images with CECT-corrected attenuation and 4.4 ± 2.0 in PET images with NCCT- corrected attenuation. The limit of agreement was 0.4 ± 0.8 in Bland-Altman analysis. Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of

  2. Dynamic neurotransmitter interactions measured with PET

    International Nuclear Information System (INIS)

    Schiffer, W.K.; Dewey, S.L.

    2001-01-01

    biologically distinct neurochemical systems that interact to produce a variety of behaviors and disorders. Neurotransmitters are neither static nor isolated in their distribution. In fact, it is through interactions with other neurochemically distinct systems that the central nervous system (CNS) performs its vital role in sustaining life. Exclusive quantitative capabilities intrinsic to PET make this technology a suitable experimental tool to measure not only the regional distribution of specific receptors and their subtypes, but also the dynamic properties of neuroreceptors and their inherent influence on related neurotransmitter pathways. The ability to investigate dynamic properties in a non-invasive and reproducible manner provides a powerful tool that can extend our current knowledge of these interactions. Coupled with innovative paradigms including pharmacologic manipulations, physiologic models and reconstruction theories, knowledge derived from PET studies can greatly advance our understanding of normal and abnormal brain function

  3. Dynamic neurotransmitter interactions measured with PET

    Energy Technology Data Exchange (ETDEWEB)

    Schiffer, W.K.; Dewey, S.L.

    2001-04-02

    biologically distinct neurochemical systems that interact to produce a variety of behaviors and disorders. Neurotransmitters are neither static nor isolated in their distribution. In fact, it is through interactions with other neurochemically distinct systems that the central nervous system (CNS) performs its vital role in sustaining life. Exclusive quantitative capabilities intrinsic to PET make this technology a suitable experimental tool to measure not only the regional distribution of specific receptors and their subtypes, but also the dynamic properties of neuroreceptors and their inherent influence on related neurotransmitter pathways. The ability to investigate dynamic properties in a non-invasive and reproducible manner provides a powerful tool that can extend our current knowledge of these interactions. Coupled with innovative paradigms including pharmacologic manipulations, physiologic models and reconstruction theories, knowledge derived from PET studies can greatly advance our understanding of normal and abnormal brain function.

  4. Imaging performance of LabPET APD-based digital PET scanners for pre-clinical research

    International Nuclear Information System (INIS)

    Bergeron, Mélanie; Cadorette, Jules; Beaudoin, Jean-François; Lecomte, Roger; Tétrault, Marc-André; Leroux, Jean-Daniel; Fontaine, Réjean

    2014-01-01

    The LabPET is an avalanche photodiode (APD) based digital PET scanner with quasi-individual detector read-out and highly parallel electronic architecture for high-performance in vivo molecular imaging of small animals. The scanner is based on LYSO and LGSO scintillation crystals (2×2×12/14 mm 3 ), assembled side-by-side in phoswich pairs read out by an APD. High spatial resolution is achieved through the individual and independent read-out of an individual APD detector for recording impinging annihilation photons. The LabPET exists in three versions, LabPET4 (3.75 cm axial length), LabPET8 (7.5 cm axial length) and LabPET12 (11.4 cm axial length). This paper focuses on the systematic characterization of the three LabPET versions using two different energy window settings to implement a high-efficiency mode (250–650 keV) and a high-resolution mode (350–650 keV) in the most suitable operating conditions. Prior to measurements, a global timing alignment of the scanners and optimization of the APD operating bias have been carried out. Characteristics such as spatial resolution, absolute sensitivity, count rate performance and image quality have been thoroughly investigated following the NEMA NU 4-2008 protocol. Phantom and small animal images were acquired to assess the scanners' suitability for the most demanding imaging tasks in preclinical biomedical research. The three systems achieve the same radial FBP spatial resolution at 5 mm from the field-of-view center: 1.65/3.40 mm (FWHM/FWTM) for an energy threshold of 250 keV and 1.51/2.97 mm for an energy threshold of 350 keV. The absolute sensitivity for an energy window of 250–650 keV is 1.4%/2.6%/4.3% for LabPET4/8/12, respectively. The best count rate performance peaking at 362 kcps is achieved by the LabPET12 with an energy window of 250–650 keV and a mouse phantom (2.5 cm diameter) at an activity of 2.4 MBq ml −1 . With the same phantom, the scatter fraction for all scanners is about

  5. Use of FDG PET/CT for investigation of febrile neutropenia: evaluation in high-risk cancer patients

    International Nuclear Information System (INIS)

    Guy, Stephen D.; Tramontana, Adrian R.; Worth, Leon J.; Thursky, Karin A.; Slavin, Monica A.; Lau, Eddie; Hicks, Rodney J.; Seymour, John F.

    2012-01-01

    Febrile neutropenia (FNP) is a frequent complication of cancer care and evaluation often fails to identify a cause. [ 18 F]FDG PET/CT has the potential to identify inflammatory and infectious foci, but its potential role as an investigation for persistent FNP has not previously been explored. The aim of this study was to prospectively evaluate the clinical utility of FDG PET/CT in patients with cancer and severe neutropenia and five or more days of persistent fever despite antibiotic therapy. Adult patients with a diagnosis of an underlying malignancy and persistent FNP (temperature ≥38 C and neutrophil count <500 cells/μl for 5 days) underwent FDG PET/CT as an adjunct to conventional evaluation and management. The study group comprised 20 patients with FNP who fulfilled the eligibility criteria and underwent FDG PET/CT in addition to conventional evaluation. The median neutrophil count on the day of the FDG PET/CT scan was 30 cells/μl (range 0-730 cells/μl). Conventional evaluation identified 14 distinct sites of infection, 13 (93 %) of which were also identified by FDG PET/CT, including all deep tissue infections. FDG PET/CT identified 9 additional likely infection sites, 8 of which were subsequently confirmed as ''true positives'' by further investigations. FDG PET/CT was deemed to be of 'high' clinical impact in 15 of the 20 patients (75 %). This study supports the utility of FDG PET/CT scanning in severely neutropenic patients with five or more days of fever. Further evaluation of the contribution of FDG PET/CT in the management of FNP across a range of underlying malignancies is required. (orig.)

  6. Use of FDG PET/CT for investigation of febrile neutropenia: evaluation in high-risk cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Guy, Stephen D.; Tramontana, Adrian R. [Western Health, Department of Infectious Diseases, Private Bag, Footscray, Victoria (Australia); University of Melbourne, Parkville, Victoria (Australia); Worth, Leon J.; Thursky, Karin A.; Slavin, Monica A. [University of Melbourne, Parkville, Victoria (Australia); Peter MacCallum Cancer Centre, Department of Infectious Diseases, Melbourne, Victoria (Australia); Lau, Eddie; Hicks, Rodney J. [University of Melbourne, Parkville, Victoria (Australia); Peter MacCallum Cancer Centre, Centre for Cancer Imaging, Melbourne, Victoria (Australia); Seymour, John F. [University of Melbourne, Parkville, Victoria (Australia); Peter MacCallum Cancer Centre, Department of Haematology, Melbourne, Victoria (Australia)

    2012-08-15

    Febrile neutropenia (FNP) is a frequent complication of cancer care and evaluation often fails to identify a cause. [{sup 18} F]FDG PET/CT has the potential to identify inflammatory and infectious foci, but its potential role as an investigation for persistent FNP has not previously been explored. The aim of this study was to prospectively evaluate the clinical utility of FDG PET/CT in patients with cancer and severe neutropenia and five or more days of persistent fever despite antibiotic therapy. Adult patients with a diagnosis of an underlying malignancy and persistent FNP (temperature {>=}38 C and neutrophil count <500 cells/{mu}l for 5 days) underwent FDG PET/CT as an adjunct to conventional evaluation and management. The study group comprised 20 patients with FNP who fulfilled the eligibility criteria and underwent FDG PET/CT in addition to conventional evaluation. The median neutrophil count on the day of the FDG PET/CT scan was 30 cells/{mu}l (range 0-730 cells/{mu}l). Conventional evaluation identified 14 distinct sites of infection, 13 (93 %) of which were also identified by FDG PET/CT, including all deep tissue infections. FDG PET/CT identified 9 additional likely infection sites, 8 of which were subsequently confirmed as ''true positives'' by further investigations. FDG PET/CT was deemed to be of 'high' clinical impact in 15 of the 20 patients (75 %). This study supports the utility of FDG PET/CT scanning in severely neutropenic patients with five or more days of fever. Further evaluation of the contribution of FDG PET/CT in the management of FNP across a range of underlying malignancies is required. (orig.)

  7. The accuracy of {sup 68}Ga-PSMA PET/CT in primary lymph node staging in high-risk prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oebek, Can; Doganca, Tuenkut [Acibadem Taksim Hospital, Department of Urology, Istanbul (Turkey); Demirci, Emre [Sisli Etfal Training and Research Hospital, Department of Nuclear Medicine, Istanbul (Turkey); Ocak, Meltem [Istanbul University, Faculty of Pharmacy, Department of Pharmaceutical Technology, Istanbul (Turkey); Kural, Ali Riza [Acibadem University, Department of Urology, Istanbul (Turkey); Yildirim, Asif [Istanbul Medeniyet University, Department of Urology, Istanbul (Turkey); Yuecetas, Ugur [Istanbul Training and Research Hospital, Department of Urology, Istanbul (Turkey); Demirdag, Cetin [Istanbul University, Cerrahpasa School of Medicine, Department of Urology, Istanbul (Turkey); Erdogan, Sarper M. [Istanbul University, Cerrahpasa School of Medicine, Department of Public Health, Istanbul (Turkey); Kabasakal, Levent [Istanbul University, Cerrahpasa School of Medicine, Department of Nuclear Medicine, Istanbul (Turkey); Collaboration: Members of Urooncology Association, Turkey

    2017-10-15

    To assess the diagnostic accuracy of {sup 68}Ga-PSMA PET in predicting lymph node (LN) metastases in primary N staging in high-risk and very high-risk nonmetastatic prostate cancer in comparison with morphological imaging. This was a multicentre trial of the Society of Urologic Oncology in Turkey in conjunction with the Nuclear Medicine Department of Cerrahpasa School of Medicine, Istanbul University. Patients were accrued from eight centres. Patients with high-risk and very high-risk disease scheduled to undergo surgical treatment with extended LN dissection between July 2014 and October 2015 were included. Either MRI or CT was used for morphological imaging. PSMA PET/CT was performed and evaluated at a single centre. Sensitivity, specificity and accuracy were calculated for the detection of lymphatic metastases by PSMA PET/CT and morphological imaging. Kappa values were calculated to evaluate the correlation between the numbers of LN metastases detected by PSMA PET/CT and by histopathology. Data on 51 eligible patients are presented. The sensitivity, specificity and accuracy of PSMA PET in detecting LN metastases in the primary setting were 53%, 86% and 76%, and increased to 67%, 88% and 81% in the subgroup with of patients with ≥15 LN removed. Kappa values for the correlation between imaging and pathology were 0.41 for PSMA PET and 0.18 for morphological imaging. PSMA PET/CT is superior to morphological imaging for the detection of metastatic LNs in patients with primary prostate cancer. Surgical dissection remains the gold standard for precise lymphatic staging. (orig.)

  8. Evaluation of a high resolution silicon PET insert module

    Energy Technology Data Exchange (ETDEWEB)

    Grkovski, Milan, E-mail: milan.grkovski@ijs.si [Jožef Stefan Institute, Ljubljana (Slovenia); Memorial Sloan Kettering Cancer Center, New York, NY (United States); Brzezinski, Karol [IFIC/CSIC, Valencia (Spain); Cindro, Vladimir [Jožef Stefan Institute, Ljubljana (Slovenia); Clinthorne, Neal H. [University of Michigan, Ann Arbor, MI (United States); Kagan, Harris [Ohio State University, Columbus, OH (United States); Lacasta, Carlos [IFIC/CSIC, Valencia (Spain); Mikuž, Marko [Jožef Stefan Institute, Ljubljana (Slovenia); Solaz, Carles [IFIC/CSIC, Valencia (Spain); Studen, Andrej [Jožef Stefan Institute, Ljubljana (Slovenia); Weilhammer, Peter [Ohio State University, Columbus, OH (United States); Žontar, Dejan [Jožef Stefan Institute, Ljubljana (Slovenia)

    2015-07-11

    Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm{sup 2} pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (2D) geometry with a Jaszczak phantom (rod diameters of 1.2–4.8 mm) filled with {sup 18}F-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm)

  9. Impact of high (131)I-activities on quantitative (124)I-PET

    DEFF Research Database (Denmark)

    Braad, P E N; Hansen, Søren B.; Høilund-Carlsen, P F

    2015-01-01

    relevant [Formula: see text]I/[Formula: see text]I-activities were performed on a clinical PET/CT-system. Noise equivalent count rate (NECR) curves and quantitation accuracy were determined from repeated scans performed over several weeks on a decaying NEMA NU-2 1994 cylinder phantom initially filled...... [Formula: see text]I-activities was good and image quantification unaffected except at very high count rates. Quantitation accuracy and contrast recovery were uninfluenced at [Formula: see text]I-activities below 1000 MBq, whereas image noise was slightly increased. The NECR peaked at 550 MBq of [Formula......: see text]I, where it was 2.8 times lower than without [Formula: see text]I in the phantom. Quantitative peri-therapeutic [Formula: see text]I-PET is feasible....

  10. Application of PET in breast cancer

    International Nuclear Information System (INIS)

    Noh, Dong Young

    2002-01-01

    Positron emission tomography (PET) is an imaging method that employs radionuclide and tomography techniques. Since 1995, we applied PET not only to the diagnosis of breast cancer but also to the detection of abnormalities in the augmented breast and to the detection of metastasis. Until 2001, we evaluated 242 breast cases by PET at PET center of Seoul National University Hospital. Our group has reported serially at the international journals. In the firtst report, PET showed high sensitivity for detecting breast cancer, both the primary and axillary node metastasis. A total of 27 patients underwent breast operations based on PET results at Seoul National University Hospital from 1995 to 1996. The diagnostic accuracy of PET were 97% for the primary tumor mass and 96% for axillary lymph node metastasis. In case of the breast augmented, PET also showed excellent diagnostic results for primary breast cancer and axillary lymph node metastasis where mammography and ultrasound could not diagnose properly. PET also had outstanding results in the detection of recurrent or metastatic breast cancer(sensitivity 94%, specificity 80%, accuracy 89%). In addition, our study gave some evidence that PET could be applied further to evaluate the growth rate of tumors by measuring SUV, and finally to prognosticated the disease. PET could also be applied to evaluate the response after chemotherapy to measure its metabolic rate and size. In conclsion, PET is a highly sensitive, accurate diagnostic tool for breast cancer of primary lesion in various conditions including metastasis

  11. Recommendations for the use of PET and PET-CT for radiotherapy planning in research projects.

    Science.gov (United States)

    Somer, E J; Pike, L C; Marsden, P K

    2012-08-01

    With the increasing use of positron emission tomography (PET) for disease staging, follow-up and therapy monitoring in a number of oncological indications there is growing interest in the use of PET and PET-CT for radiation treatment planning. In order to create a strong clinical evidence base for this, it is important to ensure that research data are clinically relevant and of a high quality. Therefore the National Cancer Research Institute PET Research Network make these recommendations to assist investigators in the development of radiotherapy clinical trials involving the use of PET and PET-CT. These recommendations provide an overview of the current literature in this rapidly evolving field, including standards for PET in clinical trials, disease staging, volume delineation, intensity modulated radiotherapy and PET-augmented planning techniques, and are targeted at a general audience. We conclude with specific recommendations for the use of PET in radiotherapy planning in research projects.

  12. PET Imaging Stability Measurements During Simultaneous Pulsing of Aggressive MR Sequences on the SIGNA PET/MR System.

    Science.gov (United States)

    Deller, Timothy W; Khalighi, Mohammad Mehdi; Jansen, Floris P; Glover, Gary H

    2018-01-01

    The recent introduction of simultaneous whole-body PET/MR scanners has enabled new research taking advantage of the complementary information obtainable with PET and MRI. One such application is kinetic modeling, which requires high levels of PET quantitative stability. To accomplish the required PET stability levels, the PET subsystem must be sufficiently isolated from the effects of MR activity. Performance measurements have previously been published, demonstrating sufficient PET stability in the presence of MR pulsing for typical clinical use; however, PET stability during radiofrequency (RF)-intensive and gradient-intensive sequences has not previously been evaluated for a clinical whole-body scanner. In this work, PET stability of the GE SIGNA PET/MR was examined during simultaneous scanning of aggressive MR pulse sequences. Methods: PET performance tests were acquired with MR idle and during simultaneous MR pulsing. Recent system improvements mitigating RF interference and gain variation were used. A fast recovery fast spin echo MR sequence was selected for high RF power, and an echo planar imaging sequence was selected for its high heat-inducing gradients. Measurements were performed to determine PET stability under varying MR conditions using the following metrics: sensitivity, scatter fraction, contrast recovery, uniformity, count rate performance, and image quantitation. A final PET quantitative stability assessment for simultaneous PET scanning during functional MRI studies was performed with a spiral in-and-out gradient echo sequence. Results: Quantitation stability of a 68 Ge flood phantom was demonstrated within 0.34%. Normalized sensitivity was stable during simultaneous scanning within 0.3%. Scatter fraction measured with a 68 Ge line source in the scatter phantom was stable within the range of 40.4%-40.6%. Contrast recovery and uniformity were comparable for PET images acquired simultaneously with multiple MR conditions. Peak noise equivalent count

  13. Transconvolution and the virtual positron emission tomograph—A new method for cross calibration in quantitative PET/CT imaging

    International Nuclear Information System (INIS)

    Prenosil, George A.; Weitzel, Thilo; Hentschel, Michael; Klaeser, Bernd; Krause, Thomas

    2013-01-01

    Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET/CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. Results: The proposed Transconvolution method matched different PET/CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. Conclusions: By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.

  14. {sup 18}F-FDG PET and PET/CT in Burkitt's lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Karantanis, Dimitrios, E-mail: dkarantanis@nuclmed.ne [Division of Nuclear Medicine, Department of Radiology, Mayo Clinic, Rochester, MN (United States); Durski, Jolanta M.; Lowe, Val J.; Nathan, Mark A.; Mullan, Brian P. [Division of Nuclear Medicine, Department of Radiology, Mayo Clinic, Rochester, MN (United States); Georgiou, Evangelos [Medical Physics Department, Medical School, University of Athens (Greece); Johnston, Patrick B. [Division of Hematology, Department of Medicine, Mayo Clinic, Rochester, MN (United States); Wiseman, Gregory A. [Division of Nuclear Medicine, Department of Radiology, Mayo Clinic, Rochester, MN (United States)

    2010-07-15

    Objective: To explore the value of {sup 18}F fluorodeoxy-glucose (FDG) positron emission tomography (PET) in Burkitt's lymphoma. Methods: All Burkitt's lymphoma patients referred for FDG PET or FDG PET/computed tomography (CT) exams at our institution from June 2003 to June 2006 were included. Selected patients were followed and clinical information was reviewed retrospectively. Results from FDG PET-PET/CT, as blindly reviewed by a consensus of two experienced readers, were compared with the status of the disease as determined by other laboratory, clinical and imaging exams and clinical follow-up. FDG PET-PET/CT results were classified as true positive or negative and false positive or negative. The degree of FDG uptake in the positive lesions was semiquantified as maximum standard uptake value (SUVmax). Results: Fifty-seven FDG PET-PET/CT exams were done in 15 patients. Seven exams were done for initial staging, 8 during and 14 after the completion of therapy, and 28 for disease surveillance. For nodal disease FDG PET-PET/CT was true positive in 8, true negative in 47 and false positive in 2 exams (sensitivity 100%, specificity 96%). For extranodal disease FDG PET-PET/CT was true positive in 6, true negative in 48 and false positive in 3 exams (sensitivity 100%, specificity 94%). The mean SUVmax for the positive nodal lesions was 15.7 (range 6.9-21.7, median 18.5) and for extranodal lesions was 14.2 (range 6.2-24.3, median 12.4). Conclusions: FDG PET-PET/CT is sensitive for the detection of viable disease in Burkitt's lymphoma. Affected areas demonstrated high degree of uptake that was reversible upon successful implementation of treatment.

  15. Development of high shrinkage polyethylene terephthalate (PET) shape memory polymer tendons for concrete crack closure

    Science.gov (United States)

    Teall, Oliver; Pilegis, Martins; Sweeney, John; Gough, Tim; Thompson, Glen; Jefferson, Anthony; Lark, Robert; Gardner, Diane

    2017-04-01

    The shrinkage force exerted by restrained shape memory polymers (SMPs) can potentially be used to close cracks in structural concrete. This paper describes the physical processing and experimental work undertaken to develop high shrinkage die-drawn polyethylene terephthalate (PET) SMP tendons for use within a crack closure system. The extrusion and die-drawing procedure used to manufacture a series of PET tendon samples is described. The results from a set of restrained shrinkage tests, undertaken at differing activation temperatures, are also presented along with the mechanical properties of the most promising samples. The stress developed within the tendons is found to be related to the activation temperature, the cross-sectional area and to the draw rate used during manufacture. Comparisons with commercially-available PET strip samples used in previous research are made, demonstrating an increase in restrained shrinkage stress by a factor of two for manufactured PET filament samples.

  16. PET-Probe: Evaluation of Technical Performance and Clinical Utility of a Handheld High-Energy Gamma Probe in Oncologic Surgery.

    Science.gov (United States)

    Gulec, Seza A; Daghighian, Farhad; Essner, Richard

    2016-12-01

    Positron emission tomography (PET) has become an invaluable part of patient evaluation in surgical oncology. PET is less than optimal for detecting lesions PET-positive lesions can be challenging as a result of difficulties in surgical exposure. We undertook this investigation to assess the utility of a handheld high-energy gamma probe (PET-Probe) for intraoperative identification of 18 F-deoxyglucose (FDG)-avid tumors. Forty patients underwent a diagnostic whole-body FDG-PET scan for consideration for surgical exploration and resection. Before surgery, all patients received an intravenous injection of 7 to 10 mCi of FDG. At surgery, the PET-Probe was used to determine absolute counts per second at the known tumor site(s) demonstrated by whole-body PET and at adjacent normal tissue (at least 4 cm away from tumor-bearing sites). Tumor-to-background ratios were calculated. Thirty-two patients (80%) underwent PET-Probe-guided surgery with therapeutic intent in a recurrent or metastatic disease setting. Eight patients underwent surgery for diagnostic exploration. Anatomical locations of the PET-identified lesions were neck and supraclavicular (n = 8), axilla (n = 5), groin and deep iliac (n = 4), trunk and extremity soft tissue (n = 3), abdominal and retroperitoneal (n = 19), and lung (n = 2). PET-Probe detected all PET-positive lesions. The PET-Probe was instrumental in localization of lesions in 15 patients that were not immediately apparent by surgical exploration. The PET-Probe identified all lesions demonstrated by PET scanning and, in selected cases, was useful in localizing FDG-avid disease not seen with conventional PET scanning.

  17. Assessment of Physiological Equivalent Temperature (PET in Transitional Spaces of a High-Rise Building

    Directory of Open Access Journals (Sweden)

    Nooriati Taib

    2016-01-01

    Full Text Available One passive approach that can significantly reduce energy usage in high-rise buildings is through the creation of non-air conditioned spaces such as transitional spaces. Optimizing passive design would reduce wastage associated with the building’s energy consumption. The study measures the thermal comfort of three types of transitional spaces (sky court, balcony, and rooftop in a high-rise office building. Based on the assessment of Physiological Equivalent Temperature (PET, the outcome showed significant differences in PET in all locations in both wet and dry season. The effectiveness of such area can be improved with the contributions of landscape, maximizing natural ventilation and day lighting where possible.

  18. Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants

    International Nuclear Information System (INIS)

    Goerres, Gerhard W.; Hany, Thomas F.; Kamel, Ehab; Schulthess von, Gustav K.; Buck, Alfred

    2002-01-01

    Germanium-68 based attenuation correction (PET Ge68 ) is performed in positron emission tomography (PET) imaging for quantitative measurements. With the recent introduction of combined in-line PET/CT scanners, CT data can be used for attenuation correction. Since dental implants can cause artefacts in CT images, CT-based attenuation correction (PET CT ) may induce artefacts in PET images. The purpose of this study was to evaluate the influence of dental metallic artwork on the quality of PET images by comparing non-corrected images and images attenuation corrected by PET Ge68 and PET CT . Imaging was performed on a novel in-line PET/CT system using a 40-mAs scan for PET CT in 41 consecutive patients with high suspicion of malignant or inflammatory disease. In 17 patients, additional PET Ge68 images were acquired in the same imaging session. Visual analysis of fluorine-18 fluorodeoxyglucose (FDG) distribution in several regions of the head and neck was scored on a 4-point scale in comparison with normal grey matter of the brain in the corresponding PET images. In addition, artefacts adjacent to dental metallic artwork were evaluated. A significant difference in image quality scoring was found only for the lips and the tip of the nose, which appeared darker on non-corrected than on corrected PET images. In 33 patients, artefacts were seen on CT, and in 28 of these patients, artefacts were also seen on PET imaging. In eight patients without implants, artefacts were seen neither on CT nor on PET images. Direct comparison of PET Ge68 and PET CT images showed a different appearance of artefacts in 3 of 17 patients. Malignant lesions were equally well visible using both transmission correction methods. Dental implants, non-removable bridgework etc. can cause artefacts in attenuation-corrected images using either a conventional 68 Ge transmission source or the CT scan obtained with a combined PET/CT camera. We recommend that the non-attenuation-corrected PET images also be

  19. Highly Efficient and Reproducible Nonfullerene Solar Cells from Hydrocarbon Solvents

    KAUST Repository

    Wadsworth, Andrew; Ashraf, Raja; Abdelsamie, Maged; Pont, Sebastian; Little, Mark; Moser, Maximilian; Hamid, Zeinab; Neophytou, Marios; Zhang, Weimin; Amassian, Aram; Durrant, James R.; Baran, Derya; McCulloch, Iain

    2017-01-01

    With chlorinated solvents unlikely to be permitted for use in solution-processed organic solar cells in industry, there must be a focus on developing nonchlorinated solvent systems. Here we report high-efficiency devices utilizing a low-bandgap donor polymer (PffBT4T-2DT) and a nonfullerene acceptor (EH-IDTBR) from hydrocarbon solvents and without using additives. When mesitylene was used as the solvent, rather than chlorobenzene, an improved power conversion efficiency (11.1%) was achieved without the need for pre- or post-treatments. Despite altering the processing conditions to environmentally friendly solvents and room-temperature coating, grazing incident X-ray measurements confirmed that active layers processed from hydrocarbon solvents retained the robust nanomorphology obtained with hot-processed chlorinated solvents. The main advantages of hydrocarbon solvent-processed devices, besides the improved efficiencies, were the reproducibility and storage lifetime of devices. Mesitylene devices showed better reproducibility and shelf life up to 4000 h with PCE dropping by only 8% of its initial value.

  20. Highly Efficient and Reproducible Nonfullerene Solar Cells from Hydrocarbon Solvents

    KAUST Repository

    Wadsworth, Andrew

    2017-06-01

    With chlorinated solvents unlikely to be permitted for use in solution-processed organic solar cells in industry, there must be a focus on developing nonchlorinated solvent systems. Here we report high-efficiency devices utilizing a low-bandgap donor polymer (PffBT4T-2DT) and a nonfullerene acceptor (EH-IDTBR) from hydrocarbon solvents and without using additives. When mesitylene was used as the solvent, rather than chlorobenzene, an improved power conversion efficiency (11.1%) was achieved without the need for pre- or post-treatments. Despite altering the processing conditions to environmentally friendly solvents and room-temperature coating, grazing incident X-ray measurements confirmed that active layers processed from hydrocarbon solvents retained the robust nanomorphology obtained with hot-processed chlorinated solvents. The main advantages of hydrocarbon solvent-processed devices, besides the improved efficiencies, were the reproducibility and storage lifetime of devices. Mesitylene devices showed better reproducibility and shelf life up to 4000 h with PCE dropping by only 8% of its initial value.

  1. High resolution reconstruction of PET images using the iterative OSEM algorithm

    International Nuclear Information System (INIS)

    Doll, J.; Bublitz, O.; Werling, A.; Haberkorn, U.; Semmler, W.; Adam, L.E.; Pennsylvania Univ., Philadelphia, PA; Brix, G.

    2004-01-01

    Aim: Improvement of the spatial resolution in positron emission tomography (PET) by incorporation of the image-forming characteristics of the scanner into the process of iterative image reconstruction. Methods: All measurements were performed at the whole-body PET system ECAT EXACT HR + in 3D mode. The acquired 3D sinograms were sorted into 2D sinograms by means of the Fourier rebinning (FORE) algorithm, which allows the usage of 2D algorithms for image reconstruction. The scanner characteristics were described by a spatially variant line-spread function (LSF), which was determined from activated copper-64 line sources. This information was used to model the physical degradation processes in PET measurements during the course of 2D image reconstruction with the iterative OSEM algorithm. To assess the performance of the high-resolution OSEM algorithm, phantom measurements performed at a cylinder phantom, the hotspot Jaszczack phantom, and the 3D Hoffmann brain phantom as well as different patient examinations were analyzed. Results: Scanner characteristics could be described by a Gaussian-shaped LSF with a full-width at half-maximum increasing from 4.8 mm at the center to 5.5 mm at a radial distance of 10.5 cm. Incorporation of the LSF into the iteration formula resulted in a markedly improved resolution of 3.0 and 3.5 mm, respectively. The evaluation of phantom and patient studies showed that the high-resolution OSEM algorithm not only lead to a better contrast resolution in the reconstructed activity distributions but also to an improved accuracy in the quantification of activity concentrations in small structures without leading to an amplification of image noise or even the occurrence of image artifacts. Conclusion: The spatial and contrast resolution of PET scans can markedly be improved by the presented image restauration algorithm, which is of special interest for the examination of both patients with brain disorders and small animals. (orig.)

  2. Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System.

    Science.gov (United States)

    Nakamoto, Ryusuke; Nakamoto, Yuji; Ishimori, Takayoshi; Fushimi, Yasutaka; Kido, Aki; Togashi, Kaori

    2018-05-01

    The current study tested a newly developed flexible PET (fxPET) scanner prototype. This fxPET system involves dual arc-shaped detectors based on silicon photomultipliers that are designed to fit existing MRI devices, allowing us to obtain fused PET and MR images by sequential PET and MR scanning. This prospective study sought to evaluate the image quality, lesion detection rate, and quantitative values of fxPET in comparison with conventional whole-body (WB) PET and to assess the accuracy of registration. Methods: Seventeen patients with suspected or known malignant tumors were analyzed. Approximately 1 h after intravenous injection of 18 F-FDG, WB PET/CT was performed, followed by fxPET and MRI. For reconstruction of fxPET images, MRI-based attenuation correction was applied. The quality of fxPET images was visually assessed, and the number of detected lesions was compared between the 2 imaging methods. SUV max and maximum average SUV within a 1 cm 3 spheric volume (SUV peak ) of lesions were also compared. In addition, the magnitude of misregistration between fxPET and MR images was evaluated. Results: The image quality of fxPET was acceptable for diagnosis of malignant tumors. There was no significant difference in detectability of malignant lesions between fxPET and WB PET ( P > 0.05). However, the fxPET system did not exhibit superior performance to the WB PET system. There were strong positive correlations between the 2 imaging modalities in SUV max (ρ = 0.88) and SUV peak (ρ = 0.81). SUV max and SUV peak measured with fxPET were approximately 1.1-fold greater than measured with WB PET. The average misregistration between fxPET and MR images was 5.5 ± 3.4 mm. Conclusion: Our preliminary data indicate that running an fxPET scanner near an existing MRI system provides visually and quantitatively acceptable fused PET/MR images for diagnosis of malignant lesions. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  3. PET/CT: underlying physics, instrumentation, and advances.

    Science.gov (United States)

    Torres Espallardo, I

    Since it was first introduced, the main goal of PET/CT has been to provide both PET and CT images with high clinical quality and to present them to radiologists and specialists in nuclear medicine as a fused, perfectly aligned image. The use of fused PET and CT images quickly became routine in clinical practice, showing the great potential of these hybrid scanners. Thanks to this success, manufacturers have gone beyond considering CT as a mere attenuation corrector for PET, concentrating instead on design high performance PET and CT scanners with more interesting features. Since the first commercial PET/CT scanner became available in 2001, both the PET component and the CT component have improved immensely. In the case of PET, faster scintillation crystals with high stopping power such as LYSO crystals have enabled more sensitive devices to be built, making it possible to reduce the number of undesired coincidence events and to use time of flight (TOF) techniques. All these advances have improved lesion detection, especially in situations with very noisy backgrounds. Iterative reconstruction methods, together with the corrections carried out during the reconstruction and the use of the point-spread function, have improved image quality. In parallel, CT instrumentation has also improved significantly, and 64- and 128-row detectors have been incorporated into the most modern PET/CT scanners. This makes it possible to obtain high quality diagnostic anatomic images in a few seconds that both enable the correction of PET attenuation and provide information for diagnosis. Furthermore, nowadays nearly all PET/CT scanners have a system that modulates the dose of radiation that the patient is exposed to in the CT study in function of the region scanned. This article reviews the underlying physics of PET and CT imaging separately, describes the changes in the instrumentation and standard protocols in a combined PET/CT system, and finally points out the most important

  4. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis

    International Nuclear Information System (INIS)

    Jin, H.; Yuan, L.; Li, C.; Kan, Y.; Yang, J.; Hao, R.

    2014-01-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  5. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis.

    Science.gov (United States)

    Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J

    2014-03-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  6. A comparison of high dose Ga-67 SPECT and FDG PET imaging in malignant melanoma

    International Nuclear Information System (INIS)

    Kaliff, V.; Hicks, R.J.; Binns, D.S.; Henderson, M.A.; Ainslie, J.; Jenner, D.A.

    1998-01-01

    Full text: Ga-67 imaging for tumour localisation lost favour in the 1970's. With improvement in technology and use of higher doses, it has now found an important role in lymphoma. A similar phenomenon may be possible in the staging of melanoma. This study therefore compares high dose (370 MBq) Ga-67 imaging using a day 5 and 7 whole-body and comprehensive SPECT protocol, with (100 MBq) F-18 fluorodeoxyglucose (FDG) imaging using positron emission tomography (PET): a technique recently shown to be highly accurate in this condition. 85 patients; 46 males, mean age 52+17 yrs: range 22-83 yrs, underwent both studies within 9±16 days (max-91 days). Scans were judged as positive (+ve), negative (-ve) or equivocal (EQ) for local, regional and distant disease. Clinical follow-up resolved discordant scan findings. PET and Ga-67 results were concordant in 61 (70%) patients (19 with +ve, 37 -ve and 5 EQ scans). None of the 9 ps with one EQ and one eye scan had disease on follow-up. Follow-up was available in 4/5 patients with discordantly +ve (3 patients) or more extensive Ga-67 abnormality: 3 patients had disease confirmed, 1 patient false +ve (asymmetric lung hilum). Follow-up was available in 9/10 patients with discordantly +ve (3 patients) or more extensive PET abnormality: 4 patients had confirmed disease, l pt false +ve (bladder diverticulum). A further 4 patients had second primaries (2 rectal carcinomas, 1 plasmacytoma, 1 basal cell carcinoma). High dose Ga-67 scanning incorporating SPECT appears to be a reasonable alternative to FDG PET for screening patients with melanoma. In this series PET's main advantages were in the detection of other occult tumours, greater patient convenience and lower radiation dosimetry

  7. Evaluation of 19 cases of benign lesions with high accumulation of tracer on 18F-FDG PET imaging

    International Nuclear Information System (INIS)

    Wang Quanshi; Wu Hubing; Wang Mingfang; Huang Zuhan

    2003-01-01

    Objective: To review PET images of benign lesions with high accumulation of 18 F-FDG and to analyse the possibility of FDG PET imaging for differentiating the benign from the malignant. Methods: 18 F-FDG PET imaging was performed on 19 patients with benign diseases including 13 cases of active tuberculosis and 6 cases of other benign diseases. Positive pathologic or bacteriological results were obtained for all the patients. PET images were evaluated with standardized uptake value (SUV), lesion shapes , and radioactivity distribution. CT or MRI and histopathologic findings also were reviewed. Results: 1) Thirteen patients with active tuberculosis showed high uptake of 18 F-FDG. The SUV was 3.1±1.8. But radioactivity distribution in some lesions was not uniform and there were defect areas in the lesions. Histopathologic findings proved that the defect areas were induced by caseous necrosis. Seven cases of pulmonary tuberculosis showed two or multiple stripe and funicular high accumulation and other lesions displayed high uptake in sheet or irregular shape; 1 case of scrofula and 1 case of splenetic tuberculosis showed defect areas in the lesions; the other scrofula case showed focal intense uptake. Two of lumbar tuberculosis showed intense uptake in the lumbar vertebra, and one of the two cases complicated with the cold abscess showed bilateral high accumulation in the shape of sheet along musculus psoas major. In the peritoneal tuberculosis case, PET images showed diffuse incrassation and intense uptake in peritoneum and mesentery. CT findings revealed that the peritoneum and mesentery thickened. 2) Pulmonary abscess, pulmonary cryptococcus granuloma, cerebral cryptococcus granuloma, pulmonary inflammatory pseudotumor, leiomyoma, and breast adenoma all showed high accumulation in the shapes of nodule or mass. Mean SUV was 4.5±3.1. CT or MRI findings were the same as on PET images shape. Histopathologic work-up did not find necrosis in the lesions. Conclusions

  8. Comparison between PET/MR and PET/CT in evaluation of oncological patients%PET/MR与PET/CT的对比研究

    Institute of Scientific and Technical Information of China (English)

    徐白萱; 富丽萍; 关志伟; 尹大一; 刘家金; 杨晖; 张锦明; 陈英茂; 安宁豫

    2014-01-01

    Objective To verify the feasibility of the integrated PET/MR for oncological applications by comparing PET/MR with PET/CT in terms of lesion detection and quantitative measurement.Methods A total of 277 patients (165 males,112 females,average age (52.9± 12.6) years) voluntarily participated in this same-day PET/CT and PET/MR comparative study.The time interval between the two studies was 15-35 min.PET/CT images were acquired and reconstructed following standard protocols.PET/MR covered the body trunk with a sequence combination of transverse T1 weighted imaging (WI) 3D-volumetric interpolated breath-hold,T2WI turbo spin echo with fat saturation,diffusion-weighted imaging,and simultaneous PET acquisition.PET images were reconstructed by vender-provided attenuation correction methods.The results of PET/CT and PET/MR were regarded as positive if any modality (CT,PET or MRI) was positive.SUVmax was obtained by the manually drawn ROI.Detection rates were compared with x2 test and SUVmax from the two modalities was analyzed with Spearman correlation analysis.Results A total of 353 lesions were detected in 220 patients.Compared to PET/CT,PET/MR revealed 30 additional true-positive lesions,while missed 6.The detection rates between PET/CT and PET/MR were significantly different (P<0.05).The lesion-based and patient-based consistency was 89.8% (317/353) and 85.9% (189/220),respectively.There were significant correlations of SUVmax between PET/MR and PET/CT for lesions(rs =0.91,P<0.01) and for normal tissues(rs =0.62-0.76,all P<0.01).Conclusions With reference to PET/CT,integrated PET/MR may provide comparable semi-quantitative measurements of pathological lesions as well as normal tissues.Integrated PET/MR may be more effective to detect lesions in abdomen and pelvis.%目的 通过与PET/CT在病灶检测及定量分析方面的比较,论证PET/MR一体机应用于临床的可行性.方法 2012年5月至2013年2月共300例患者同天间隔15 ~ 35 min行PET/CT和PET

  9. 'Serial review on clinical PET tracers'. Application of health insurance of [15O]oxygen PET and [18F]FDG-PET

    International Nuclear Information System (INIS)

    Torizuka, Kanji

    2009-01-01

    As regards the application required for health insurance of PET, the Ministry of Health, Labour and Welfare indicates the following procedures: first, request a permission to the Ministry of Health, Labour and Welfare for the clinical use of the automatic synthetic instrument for PET drug, approved according to the Pharmaceutical Affairs Law. Second, put into practice the use of PET test, under the highly advanced medicine premises. Then, in case of gathered positive results, the health insurance is approved for this PET test. Thus, following the above mentioned procedures, first, the use of [ 15 O] oxygen PET was approved in April 1996. Second, the use of [ 18 F]FDG-PET was approved in 12 different diseases: epilepsy, ischemic heart disease and 10 different types of cancer, in April 2002. Third, in April 2006, a additional 3 types of cancer were approved. Now, we are in the process to get the health insurance of all kinds of malignant tumors (cancer and sarcoma) except for the early gastric cancer. (author)

  10. [{sup 18}F]FDG PET/CT outperforms [{sup 18}F]FDG PET/MRI in differentiated thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vrachimis, Alexis; Wenning, Christian; Weckesser, Matthias; Stegger, Lars [University Hospital Muenster, Department of Nuclear Medicine, Muenster (Germany); Burg, Matthias Christian; Allkemper, Thomas [University Hospital Muenster, Department of Clinical Radiology, Muenster (Germany); Schaefers, Michael [University Hospital Muenster, Department of Nuclear Medicine, Muenster (Germany); Westfaelische Wilhelms University Muenster, European Institute for Molecular Imaging, Muenster (Germany)

    2016-02-15

    To evaluate the diagnostic potential of PET/MRI with [{sup 18}F]FDG in comparison to PET/CT in patients with differentiated thyroid cancer suspected or known to have dedifferentiated. The study included 31 thyroidectomized and remnant-ablated patients who underwent a scheduled [{sup 18}F]FDG PET/CT scan and were then enrolled for a PET/MRI scan of the neck and thorax. The datasets (PET/CT, PET/MRI) were rated regarding lesion count, conspicuity, diameter and characterization. Standardized uptake values were determined for all [{sup 18}F]FDG-positive lesions. Histology, cytology, and examinations before and after treatment served as the standards of reference. Of 26 patients with a dedifferentiated tumour burden, 25 were correctly identified by both [{sup 18}F]FDG PET/CT and PET/MRI. Detection rates by PET/CT and PET/MRI were 97 % (113 of 116 lesions) and 85 % (99 of 113 lesions) for malignant lesions, and 100 % (48 of 48 lesions) and 77 % (37 of 48 lesions) for benign lesions, respectively. Lesion conspicuity was higher on PET/CT for both malignant and benign pulmonary lesions and in the overall rating for malignant lesions (p < 0.001). There was a difference between PET/CT and PET/MRI in overall evaluation of malignant lesions (p < 0.01) and detection of pulmonary metastases (p < 0.001). Surgical evaluation revealed three malignant lesions missed by both modalities. PET/MRI additionally failed to detect 14 pulmonary metastases and 11 benign lesions. In patients with thyroid cancer and suspected or known dedifferentiation, [{sup 18}F]FDG PET/MRI was inferior to low-dose [{sup 18}F]FDG PET/CT for the assessment of pulmonary status. However, for the assessment of cervical status, [{sup 18}F]FDG PET/MRI was equal to contrast-enhanced neck [{sup 18}F]FDG PET/CT. Therefore, [{sup 18}F]FDG PET/MRI combined with a low-dose CT scan of the thorax may provide an imaging solution when high-quality imaging is needed and high-energy CT is undesirable or the use of a contrast

  11. MRPC-PET: A new technique for high precision time and position measurements

    International Nuclear Information System (INIS)

    Doroud, K.; Hatzifotiadou, D.; Li, S.; Williams, M.C.S.; Zichichi, A.; Zuyeuski, R.

    2011-01-01

    The purpose of this paper is to consider a new technology for medical diagnosis: the MRPC-PET. This technology allows excellent time resolution together with 2-D position information thus providing a fundamental step in this field. The principle of this method is based on the Multigap Resistive Plate Chamber (MRPC) capable of high precision time measurements. We have previously found that the route to precise timing is differential readout (this requires matching anode and cathode strips); thus crossed strip readout schemes traditionally used for 2-D readout cannot be exploited. In this paper we consider the time difference from the two ends of the strip to provide a high precision measurement along the strip; the average time gives precise timing. The MRPC-PET thus provides a basic step in the field of medical technology: excellent time resolution together with 2-D position measurement.

  12. Hybrid imaging for detection of carcinoma of unknown primary: A preliminary comparison trial of whole-body PET/MRI versus PET/CT

    International Nuclear Information System (INIS)

    Ruhlmann, Verena; Ruhlmann, Marcus; Bellendorf, Alexander; Grueneisen, Johannes; Sawicki, Lino M.; Grafe, Hong; Forsting, Michael; Bockisch, Andreas; Umutlu, Lale

    2016-01-01

    Highlights: • Both 18F-FDG PET/CT and 18F-FDG PET/MRI provide a comparable diagnostic ability for detection of primary cancer and metastases in CUP-syndrome. • Both imaging methods showed comparably high lesion conspicuity and diagnostic confidence (superior assessment of cervical lesions in PET/MRI). • PET/MRI may serve as a powerful alternative, particularly for therapy monitoring or surveillance considering the long-term cumulative dose. - Abstract: Purpose: The aim of this study is to evaluate and compare the diagnostic potential of integrated whole-body [18F]FDG-PET/MRI to [18F]FDG-PET/CT for detection of a potential primary cancer and metastases in patients suspected for cancer of unknown primary (CUP). Methods: A total of 20 patients (15 male, 5 female, age 53 ± 13 years) suspect for CUP underwent a dedicated head and neck & whole-body [18F]FDG-PET/CT (Biograph mCT 128, Siemens Healthcare) and a subsequent simultaneous [18F]FDG-PET/MRI examination (Biograph mMR, Siemens Healthcare). Two readers rated the datasets (PET/CT; PET/MRI) regarding the detection of the primary cancer and metastases, lesion conspicuity (4-point ordinal scale) and diagnostic confidence (3-point ordinal scale). PET analysis comprised the assessment of maximum standardized uptake values (SUVmax) of all PET-positive lesions using volume of interest (VOI) analysis derived from the PET/CT and PET/MR datasets. All available data considering histology and imaging including prior and clinical follow-up examinations served as reference standard. Statistical analysis included comparison of mean values using Mann-Whitney U test and correlation of SUVmax using Pearson‘s correlation. Results: In 14 out of 20 patients 49 malignant lesions were present. The primary cancer could be correctly identified in 11/20 patients with both PET/CT and PET/MRI. PET/CT enabled the detection of a total 38 metastases, PET/MR respectively of 37 metastases (one lung metastasis <5mm was missed). PET/CT and

  13. Hybrid imaging for detection of carcinoma of unknown primary: A preliminary comparison trial of whole-body PET/MRI versus PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ruhlmann, Verena; Ruhlmann, Marcus; Bellendorf, Alexander [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Grueneisen, Johannes [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Sawicki, Lino M. [Department of Diagnostic and Interventional Radiology, University of Dusseldorf, Moorenstraße 5, 40225 Dusseldorf (Germany); Grafe, Hong [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Forsting, Michael [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Bockisch, Andreas [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Umutlu, Lale, E-mail: verena.ruhlmann@uk-essen.de [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany)

    2016-11-15

    Highlights: • Both 18F-FDG PET/CT and 18F-FDG PET/MRI provide a comparable diagnostic ability for detection of primary cancer and metastases in CUP-syndrome. • Both imaging methods showed comparably high lesion conspicuity and diagnostic confidence (superior assessment of cervical lesions in PET/MRI). • PET/MRI may serve as a powerful alternative, particularly for therapy monitoring or surveillance considering the long-term cumulative dose. - Abstract: Purpose: The aim of this study is to evaluate and compare the diagnostic potential of integrated whole-body [18F]FDG-PET/MRI to [18F]FDG-PET/CT for detection of a potential primary cancer and metastases in patients suspected for cancer of unknown primary (CUP). Methods: A total of 20 patients (15 male, 5 female, age 53 ± 13 years) suspect for CUP underwent a dedicated head and neck & whole-body [18F]FDG-PET/CT (Biograph mCT 128, Siemens Healthcare) and a subsequent simultaneous [18F]FDG-PET/MRI examination (Biograph mMR, Siemens Healthcare). Two readers rated the datasets (PET/CT; PET/MRI) regarding the detection of the primary cancer and metastases, lesion conspicuity (4-point ordinal scale) and diagnostic confidence (3-point ordinal scale). PET analysis comprised the assessment of maximum standardized uptake values (SUVmax) of all PET-positive lesions using volume of interest (VOI) analysis derived from the PET/CT and PET/MR datasets. All available data considering histology and imaging including prior and clinical follow-up examinations served as reference standard. Statistical analysis included comparison of mean values using Mann-Whitney U test and correlation of SUVmax using Pearson‘s correlation. Results: In 14 out of 20 patients 49 malignant lesions were present. The primary cancer could be correctly identified in 11/20 patients with both PET/CT and PET/MRI. PET/CT enabled the detection of a total 38 metastases, PET/MR respectively of 37 metastases (one lung metastasis <5mm was missed). PET/CT and

  14. Imaging with 124I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    International Nuclear Information System (INIS)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J.; Umutlu, L.

    2016-01-01

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using 124 I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT 2 ) followed by PET/MRI of the neck 24 h after 124 I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT 2 acquisition time (2 min, PET/MRI 2 ) and the other covering the whole MRI scan time (30 min, PET/MRI 30 ). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI 2 detected significantly more iodine-positive metastases and thyroid remnants than PET/CT 2 (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI 30 tended to detect more PET-positive metastases than PET/MRI 2 (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine-positive lesions as either metastasis or thyroid remnant

  15. Pet Problems at Home: Pet Problems in the Community.

    Science.gov (United States)

    Soltow, Willow

    1984-01-01

    Discusses problems of pets in the community, examining the community's role related to disruptive pets and pet overpopulation. Also discusses pet problems at home, offering advice on selecting a pet, meeting a pet's needs, and disciplining pets. Includes a list of books, films/filmstrips, teaching materials, and various instructional strategies.…

  16. Evacuating People and Their Pets: Older Floridians' Need for and Proximity to Pet-Friendly Shelters.

    Science.gov (United States)

    Douglas, Rachel; Kocatepe, Ayberk; Barrett, Anne E; Ozguven, Eren Erman; Gumber, Clayton

    2017-10-04

    Pets influence evacuation decisions, but little is known about pet-friendly emergency shelters' availability or older adults' need for them. Our study addresses this issue, focusing on the most densely populated area of Florida (Miami-Dade)-the state with the oldest population and greatest hurricane susceptibility. We use Geographic Information Systems (GIS)-based methodology to identify the shortest paths to pet-friendly shelters, based on distance and congested and uncongested travel times-taking into account the older population's spatial distribution. Logistic regression models using the 2013 American Housing Survey's Disaster Planning Module examine anticipated shelter use as a function of pet ownership and requiring pet evacuation assistance. Thirty-four percent of older adults in the Miami-Dade area have pets-35% of whom report needing pet evacuation assistance. However, GIS accessibility measures show that travel time factors are likely to impede older adults' use of the area's few pet-friendly shelters. Logistic regression results reveal that pet owners are less likely to report anticipating shelter use; however, the opposite holds for pet owners reporting they would need help evacuating their pets-they anticipate using shelters. High pet shelter need coupled with low availability exacerbates older adults' heightened vulnerability during Florida's hurricane season. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. MO-DE-207B-07: Assessment of Reproducibility Of FDG-PET-Based Radiomics Features Across Scanners Using Phantom Imaging

    International Nuclear Information System (INIS)

    Fried, D; Meier, J; Mawlawi, O; Zhou, S; Ibbott, G; Liao, Z; Court, L

    2016-01-01

    Purpose: Use a NEMA-IEC PET phantom to assess the robustness of FDG-PET-based radiomics features to changes in reconstruction parameters across different scanners. Methods: We scanned a NEMA-IEC PET phantom on 3 different scanners (GE Discovery VCT, GE Discovery 710, and Siemens mCT) using a FDG source-to-background ratio of 10:1. Images were retrospectively reconstructed using different iterations (2–3), subsets (21–24), Gaussian filter widths (2, 4, 6mm), and matrix sizes (128,192,256). The 710 and mCT used time-of-flight and point-spread-functions in reconstruction. The axial-image through the center of the 6 active spheres was used for analysis. A region-of-interest containing all spheres was able to simulate a heterogeneous lesion due to partial volume effects. Maximum voxel deviations from all retrospectively reconstructed images (18 per scanner) was compared to our standard clinical protocol. PET Images from 195 non-small cell lung cancer patients were used to compare feature variation. The ratio of a feature’s standard deviation from the patient cohort versus the phantom images was calculated to assess for feature robustness. Results: Across all images, the percentage of voxels differing by 3) were observed for routinely used SUV metrics (e.g. SUVmean and SUVmax) as well as some radiomics features (e.g. co-occurrence contrast, co-occurrence energy, standard deviation, and uniformity). Similar standard deviation ratios were observed across scanners. Conclusions: Our method enabled a comparison of feature variability across scanners and was able to identify features that were not robust to changes in reconstruction parameters.

  18. Interference between PET and MRI sub-systems in a silicon-photomultiplier-based PET/MRI system

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Hatazawa, Jun; Aoki, Masaaki; Sugiyama, Eiji; Watabe, Tadashi; Imaizumi, Masao; Shimosegawa, Eku

    2011-01-01

    The silicon-photomultiplier (Si-PM) is a promising photodetector, especially for integrated PET/MRI systems, due to its small size, high gain, and low sensitivity to static magnetic fields. The major problem using a Si-PM-based PET system within the MRI system is the interference between the PET and MRI units. We measured the interference by combining a Si-PM-based PET system with a permanent-magnet MRI system. When the RF signal-induced pulse height exceeded the lower energy threshold level of the PET system, interference between the Si-PM-based PET system and MRI system was detected. The prompt as well as the delayed coincidence count rates of the Si-PM-based PET system increased significantly. These noise counts produced severe artifacts on the reconstructed images of the Si-PM-based PET system. In terms of the effect of the Si-PM-based PET system on the MRI system, although no susceptibility artifact was observed on the MR images, electronic noise from the PET detector ring was detected by the RF coil and reduced the signal-to-noise ratio (S/N) of the MR images. The S/N degradation of the MR images was reduced when the distance between the RF coil and the Si-PM-based PET system was increased. We conclude that reducing the interference between the PET and MRI systems is essential for achieving the optimum performance of integrated Si-PM PET/MRI systems.

  19. High impact of FDG-PET/CT in diagnostic strategies for ovarian cancer

    International Nuclear Information System (INIS)

    Zytoon, Ashraf Anas; Murakami, Koji; Eid, Hazem; El-Gammal, Mahmoud

    2013-01-01

    Background: Ovarian cancer has the highest mortality of all gynecologic malignancies. FDG-PET/CT was proven to be accurate for identification of primary ovarian tumors, regional lymph nodes, and distant metastases. Purpose: To evaluate ovarian masses at FDG-PET/CT in correlation with histopathologic findings. Material and Methods: Ninety-eight patients underwent whole body FDG-PET/CT examination. Eighty-six patients with primary ovarian cancer and 12 patients with metastatic disease to the ovaries were included. Results: PET/CT imaging was true-positive in 87/94 patients with malignant tumors. In 4/4 patients with benign tumors, PET/CT results were true-negative, with sensitivity of 92.6%, specificity 100%, total test accuracy 92.9%. Fifty-seven patients were diagnosed as stage IV ovarian cancer with distant metastasis. Conclusion: The anatomical/functional examination by FDG-PET/CT was proven to be valuable in increasing the diagnostic accuracy that can help improve patient management

  20. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    OpenAIRE

    Mustafa Demir; Türkay Toklu; Mohammad Abuqbeitah; Hüseyin Çetin; H. Sezer Sezgin; Nami Yeyin; Kerim Sönmezoğlu

    2018-01-01

    Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated...

  1. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    OpenAIRE

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H. Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-01-01

    Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated asp...

  2. Simulation study comparing the helmet-chin PET with a cylindrical PET of the same number of detectors

    Science.gov (United States)

    Ahmed, Abdella M.; Tashima, Hideaki; Yoshida, Eiji; Nishikido, Fumihiko; Yamaya, Taiga

    2017-06-01

    There is a growing interest in developing brain PET scanners with high sensitivity and high spatial resolution for early diagnosis of neurodegenerative diseases and studies of brain functions. Sensitivity of the PET scanner can be improved by increasing the solid angle. However, conventional PET scanners are designed based on a cylindrical geometry, which may not be the most efficient design for brain imaging in terms of the balance between sensitivity and cost. We proposed a dedicated brain PET scanner based on a hemispheric shape detector and a chin detector (referred to as the helmet-chin PET), which is designed to maximize the solid angle by increasing the number of lines-of-response in the hemisphere. The parallax error, which PET scanners with a large solid angle tend to have, can be suppressed by the use of depth-of-interaction detectors. In this study, we carry out a realistic evaluation of the helmet-chin PET using Monte Carlo simulation based on the 4-layer GSO detector which consists of a 16  ×  16  ×  4 array of crystals with dimensions of 2.8  ×  2.8  ×  7.5 mm3. The purpose of this simulation is to show the gain in imaging performance of the helmet-chin PET compared with the cylindrical PET using the same number of detectors in each configuration. The sensitivity of the helmet-chin PET evaluated with a cylindrical phantom has a significant increase, especially at the top of the (field-of-view) FOV. The peak-NECR of the helmet-chin PET is 1.4 times higher compared to the cylindrical PET. The helmet-chin PET provides relatively low noise images throughout the FOV compared to the cylindrical PET which exhibits enhanced noise at the peripheral regions. The results show the helmet-chin PET can significantly improve the sensitivity and reduce the noise in the reconstructed images.

  3. Treatment response evaluation with 18F-FDG PET/CT and 18F-NaF PET/CT in multiple myeloma patients undergoing high-dose chemotherapy and autologous stem cell transplantation.

    Science.gov (United States)

    Sachpekidis, Christos; Hillengass, J; Goldschmidt, H; Wagner, B; Haberkorn, U; Kopka, K; Dimitrakopoulou-Strauss, A

    2017-01-01

    The aim of this study was to assess the combined use of the radiotracers 18 F-FDG and 18 F-NaF in treatment response evaluation of a group of multiple myeloma (MM) patients undergoing high-dose chemotherapy (HDT) followed by autologous stem cell transplantation (ASCT) by means of static (whole-body) and dynamic PET/CT (dPET/CT). Thirty-four patients with primary, previously untreated MM scheduled for treatment with HDT followed by ASCT were enrolled in the study. All patients underwent PET/CT scanning with 18 F-FDG and 18 F-NaF before and after therapy. Treatment response by means of PET/CT was assessed according to the European Organization for Research and Treatment of Cancer (EORTC) 1999 criteria. The evaluation of dPET/CT studies was based on qualitative evaluation, semi-quantitative (SUV) calculation, and quantitative analysis based on two-tissue compartment modelling and a non-compartmental approach leading to the extraction of fractal dimension (FD). An analysis was possible in 29 patients: three with clinical complete response (CR) and 26 with non-CR (13 patients near complete response-nCR, four patients very good partial response-VGPR, nine patients partial response-PR). After treatment, 18 F-FDG PET/CT was negative in 14/29 patients and positive in 15/29 patients, showing a sensitivity of 57.5 % and a specificity of 100 %. According to the EORTC 1999 criteria, 18 F-FDG PET/CT-based treatment response revealed CR in 14 patients ( 18 F-FDG PET/CT CR), PR in 11 patients ( 18 F-FDG PET/CT PR) and progressive disease in four patients ( 18 F-FDG PET/CT PD). In terms of 18 F-NaF PET/CT, 4/29 patients (13.8 %) had a negative baseline scan, thus failed to depict MM. Regarding the patients for which a direct lesion-to-lesion comparison was feasible, 18 F-NaF PET/CT depicted 56 of the 129 18 F-FDG positive lesions (43 %). Follow-up 18 F-NaF PET/CT showed persistence of 81.5 % of the baseline 18 F-NaF positive MM lesions after treatment, despite the fact that 64

  4. The simulation of a data acquisition system for a proposed high resolution PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    Rotolo, C.; Larwill, M.; Chappa, S. [Fermi National Accelerator Lab., Batavia, IL (United States); Ordonez, C. [Chicago Univ., IL (United States)

    1993-10-01

    The simulation of a specific data acquisition (DAQ) system architecture for a proposed high resolution Positron Emission Tomography (PET) scanner is discussed. Stochastic processes are used extensively to model PET scanner signal timing and probable DAQ circuit limitations. Certain architectural parameters, along with stochastic parameters, are varied to quantatively study the resulting output under various conditions. The inclusion of the DAQ in the model represents a novel method of more complete simulations of tomograph designs, and could prove to be of pivotal importance in the optimization of such designs.

  5. The simulation of a data acquisition system for a proposed high resolution PET scanner

    International Nuclear Information System (INIS)

    Rotolo, C.; Larwill, M.; Chappa, S.; Ordonez, C.

    1993-10-01

    The simulation of a specific data acquisition (DAQ) system architecture for a proposed high resolution Positron Emission Tomography (PET) scanner is discussed. Stochastic processes are used extensively to model PET scanner signal timing and probable DAQ circuit limitations. Certain architectural parameters, along with stochastic parameters, are varied to quantatively study the resulting output under various conditions. The inclusion of the DAQ in the model represents a novel method of more complete simulations of tomograph designs, and could prove to be of pivotal importance in the optimization of such designs

  6. Choline-PET/CT for imaging prostate cancer; Cholin-PET/CT zur Bildgebung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Bernd Joachim [Klinik- und Poliklinik fuer Nuklearmedizin, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany); Treiber, U.; Schwarzenboeck, S.; Souvatzoglou, M. [Klinik fuer Urologie, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany)

    2010-09-15

    PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives are increasingly being used for imaging of prostate cancer. The value of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in biochemical recurrence of prostate cancer has been examined in many studies and demonstrates an increasing importance. Primary prostate cancer can be detected with moderate sensitivity using PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives - the differentiation between benign prostatic hyperplasia, prostatitis or high-grade intraepithelial neoplasia (HGPIN) is not always possible. At the present time [{sup 11}C]choline PET/CT is not recommended in the primary setting but may be utilized in clinically suspected prostate cancer with repeatedly negative prostate biopsies, in preparation of a focused re-biopsy. Promising results have been obtained for the use of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in patients with biochemical recurrence. The detection rate of choline PET and PET/CT for local, regional, and distant recurrence in patients with a biochemical recurrence shows a linear correlation with PSA values at the time of imaging and reaches about 75% in patients with PSA > 3 ng/mL. At PSA values below 1 ng/mL, the recurrence can be diagnosed with choline PET/CT in approximately 1/3 of the patients. PET and PET/CT with [{sup 11}C]- and [{sup 18}F]choline derivates can be helpful for choosing a therapeutic strategy in the sense of an individualized treatment: since an early diagnosis of recurrence is crucial to the choice of optimal treatment. The localization of the site of recurrence - local recurrence, lymph node metastasis or systemic dissemination - has important influence on the therapy regimen. (orig.)

  7. Reproducibility of O-(2-{sup 18}F-fluoroethyl)-L-tyrosine uptake kinetics in brain tumors and influence of corticoid therapy: an experimental study in rat gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Stegmayr, Carina; Schoeneck, Michael; Oliveira, Dennis; Willuweit, Antje [Institute of Neuroscience and Medicine, Research Center Juelich, Juelich (Germany); Filss, Christian; Coenen, Heinz H.; Langen, Karl-Josef [Institute of Neuroscience and Medicine, Research Center Juelich, Juelich (Germany); University of Aachen, Department of Nuclear Medicine and Neurology, Aachen (Germany); Galldiks, Norbert [Institute of Neuroscience and Medicine, Research Center Juelich, Juelich (Germany); University of Cologne, Department of Neurology, Cologne (Germany); Shah, N. Jon [Institute of Neuroscience and Medicine, Research Center Juelich, Juelich (Germany); University of Aachen, Department of Nuclear Medicine and Neurology, Aachen (Germany); Juelich-Aachen Research Alliance (JARA) - Section JARA-Brain, Juelich (Germany)

    2016-06-15

    Positron emission tomography (PET) using O-(2-{sup 18}F-fluoroethyl)-L-tyrosine ({sup 18}F-FET) is a well-established method for the diagnostics of brain tumors. This study investigates reproducibility of {sup 18}F-FET uptake kinetics in rat gliomas and the influence of the frequently used dexamethasone (Dex) therapy. F98 glioma or 9L gliosarcoma cells were implanted into the striatum of 31 Fischer rats. After 10-11 days of tumor growth, the animals underwent dynamic PET after injection of {sup 18}F-FET (baseline). Thereafter, animals were divided into a control group and a group receiving Dex injections, and all animals were reinvestigated 2 days later. Tumor-to-brain ratios (TBR) of {sup 18}F-FET uptake (18-61 min p.i.) and the slope of the time-activity-curves (TAC) (18-61 min p.i.) were evaluated using a Volume-of-Interest (VOI) analysis. Data were analyzed by two-way repeated measures ANOVA and reproducibility by the intraclass correlation coefficient (ICC). The slope of the tumor TACs showed high reproducibility with an ICC of 0.93. A systematic increase of the TBR in the repeated scans was noted (3.7 ± 2.8 %; p < 0.01), and appeared to be related to tumor growth as indicated by a significant correlation of TBR and tumor volume (r = 0.77; p < 0.0001). After correction for tumor growth TBR showed high longitudinal stability with an ICC of 0.84. Dex treatment induced a significant decrease of the TBR (-8.2 ± 6.1 %; p < 0.03), but did not influence the slope of the tumor TAC. TBR of {sup 18}F-FET uptake and tracer kinetics in brain tumors showed high longitudinal stability. Dex therapy may induce a minor decrease of the TBR; this needs further investigation. (orig.)

  8. Initial evaluation of a practical PET respiratory motion correction method in clinical simultaneous PET/MRI

    International Nuclear Information System (INIS)

    Manber, Richard; Thielemans, Kris; Hutton, Brian; Barnes, Anna; Ourselin, Sebastien; Arridge, Simon; O’Meara, Celia; Atkinson, David

    2014-01-01

    Respiratory motion during PET acquisitions can cause image artefacts, with sharpness and tracer quantification adversely affected due to count ‘smearing’. Motion correction by registration of PET gates becomes increasingly difficult with shorter scan times and less counts. The advent of simultaneous PET/MRI scanners allows the use of high spatial resolution MRI to capture motion states during respiration [1, 2]. In this work, we use a respiratory signal derived from the PET list-mode data [3, ], with no requirement for an external device or MR sequence modifications.

  9. FDG-PET, PET/CT and conventional nuclear medicine procedures in the evaluation of lung cancer. A systematic review

    International Nuclear Information System (INIS)

    Hellwig, Dirk; Kirsch, C.M.; Baum, R.P.

    2009-01-01

    Aim: Currently, the German and Austrian S3 guidelines on the evaluation and treatment of lung cancer are about to be published whereas the American Colleague of Chest Physicians (ACCP) guidelines were already presented in 2007. An important part of the diagnostic workup of lung cancer will be the evaluation of indeterminate lung lesions and the mediastinal and extrathoracic staging using FDG-PET or PET/CT. The results from the literature on FDG-PET and PET/CT as well as on conventional nuclear medicine staging procedures and the clinical implications are presented. Methods: The literature data was amassed in analogy to the metaanalyses drawn for the current ACCP guidelines. In addition, relevant more recent publications were also considered. To answer the important question for the extent of pathological confirmation needed, the residual risk of mediastinal metastases was calculated for certain constellations of FDG-PET and CT findings. Suggested recommendations were characterized with the level of evidence. Results: FDG-PET (PET/CT) allows the differentiation of indeterminate lung lesions with high accuracy. FDG-PET (PET/CT) is the most accurate non-invasive procedure to assess the mediastinal nodal stage, for non-small cell as well as for small cell lung cancer. It is justified to omit invasive evaluation of enlarged but FDG-PET negative lymph nodes under certain circumstances. Unexpected extrathoracic metastases detected by FDG-PET imply important changes in therapeutic management. Conclusion: The upcoming S3 guideline on lung cancer will recommend FDG-PET in several indications due to its clinical efficacy well proven by data from literature (high level of evidence). The selected use of conventional nuclear medicine procedures remains beyond doubt. FDG-PET (PET/CT) belongs to the standard of care in lung cancer

  10. FDG-PET, PET/CT and conventional nuclear medicine procedures in the evaluation of lung cancer. A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Hellwig, Dirk; Kirsch, C.M. [Saarland Univ. Medical Center, Homburg (Germany). Dept. of Nuclear Medicine; Baum, R.P. [Zentralklinik Bad Berka (Germany). Dept. of Nuclear Medicine / PET Center

    2009-07-01

    Aim: Currently, the German and Austrian S3 guidelines on the evaluation and treatment of lung cancer are about to be published whereas the American Colleague of Chest Physicians (ACCP) guidelines were already presented in 2007. An important part of the diagnostic workup of lung cancer will be the evaluation of indeterminate lung lesions and the mediastinal and extrathoracic staging using FDG-PET or PET/CT. The results from the literature on FDG-PET and PET/CT as well as on conventional nuclear medicine staging procedures and the clinical implications are presented. Methods: The literature data was amassed in analogy to the metaanalyses drawn for the current ACCP guidelines. In addition, relevant more recent publications were also considered. To answer the important question for the extent of pathological confirmation needed, the residual risk of mediastinal metastases was calculated for certain constellations of FDG-PET and CT findings. Suggested recommendations were characterized with the level of evidence. Results: FDG-PET (PET/CT) allows the differentiation of indeterminate lung lesions with high accuracy. FDG-PET (PET/CT) is the most accurate non-invasive procedure to assess the mediastinal nodal stage, for non-small cell as well as for small cell lung cancer. It is justified to omit invasive evaluation of enlarged but FDG-PET negative lymph nodes under certain circumstances. Unexpected extrathoracic metastases detected by FDG-PET imply important changes in therapeutic management. Conclusion: The upcoming S3 guideline on lung cancer will recommend FDG-PET in several indications due to its clinical efficacy well proven by data from literature (high level of evidence). The selected use of conventional nuclear medicine procedures remains beyond doubt. FDG-PET (PET/CT) belongs to the standard of care in lung cancer.

  11. The MiniPET: a didactic PET system

    International Nuclear Information System (INIS)

    Pedro, R; Silva, J; Maio, A; Gurriana, L; Silva, J M; Augusto, J Soares

    2013-01-01

    The MiniPET project aims to design and build a small PET system. It consists of two 4 × 4 matrices of 16 LYSO scintillator crystals and two PMTs with 16 channels resulting in a low cost system with the essential functionality of a clinical PET instrument. It is designed to illustrate the physics of the PET technique and to provide a didactic platform for the training of students and nuclear imaging professionals as well as for scientific outreach. The PET modules can be configured to test for the coincidence of 511 keV gamma rays. The model has a flexible mechanical setup [1] and can simulate 14 diferent ring geometries, from a configuration with as few as 18 detectors per ring (ring radius φ=51 mm), up to a geometry with 70 detectors per ring (φ=200 mm). A second version of the electronic system [2] allowed measurement and recording of the energy deposited in 4 detector channels by photons from a 137 Cs radioactive source and by photons resulting of the annihilation of positrons from a 22 Na radioactive source. These energy spectra are used for detector performance studies, as well as angular dependency studies. In this paper, the mechanical setup, the front-end high-speed analog electronics, the digital acquisition and control electronics implemented in a FPGA, as well as the data-transfer interface between the FPGA board and a host PC are described. Recent preliminary results obtained with the 4 active channels in the prototype are also presented.

  12. AX-PET: A novel PET concept with G-APD readout

    CERN Document Server

    Heller, M; Casella, C; Chesi, E; De Leo, R; Dissertori, G; Fanti, V; Gillam, J E; Joram, C; Lustermann, W; Nappi, E; Oliver, J F; Pauss, F; Rafecas, M; Rudge, A; Ruotsalainen, U; Schinzel, D; Schneider, T; Seguinot, J; Solevi, P; Stapnes, S; Tuna, U; Weilhammer, P

    2012-01-01

    The AX-PET collaboration has developed a novel concept for high resolution PET imaging to overcome some of the performance limitations of classical PET cameras, in particular the compromise between spatial resolution and sensitivity introduced by the parallax error. The detector consists of an arrangement of long LYSO scintillating crystals axially oriented around the field of view together with arrays of wave length shifter strips orthogonal to the crystals. This matrix allows a precise 3D measurement of the photon interaction point. This is valid both for photoelectric absorption at 511 key and for Compton scattering down to deposited energies of about 100 keV. Crystals and WLS strips are individually read out using Geiger-mode Avalanche Photo Diodes (G-APDs). The sensitivity of such a detector can be adjusted by changing the number of layers and the resolution is defined by the crystal and strip dimensions. Two AX-PET modules were built and fully characterized in dedicated test set-ups at CERN, with point-...

  13. Deep-inspiration breath-hold PET/CT versus free breathing PET/CT and respiratory gating PET for reference. Evaluation in 95 patients with lung cancer

    International Nuclear Information System (INIS)

    Kawano, Tsuyoshi; Ohtake, Eiji; Inoue, Tomio

    2011-01-01

    The objective of this study was to define the factors that correlate with differences in maximum standardized uptake value (SUV max ) in deep-inspiration breath-hold (DIBH) and free breathing (FB) positron emission tomography (PET)/CT admixed with respiratory gating (RG) PET for reference. Patients (n=95) with pulmonary lesions were evaluated at one facility over 33 months. After undergoing whole-body PET/CT, a RG PET and FB PET/CT scans were obtained, followed by a DIBH PET/CT scan. All scans were recorded using a list-mode dynamic collection method with respiratory gating. The RG PET was reconstructed using phase gating without attenuation correction; the FB PET was reconstructed from the RG PET sinogram datasets with attenuation correction. Respiratory motion distance, breathing cycle speed, and waveform of RG PET were recorded. The SUV max of FB PET/CT and DIBH PET/CT were recorded: the percent difference in SUV max between the FB and DIBH scans was defined as the %BH-index. The %BH-index was significantly higher for lesions in the lower lung area than in the upper lung area. Respiratory motion distance was significantly higher in the lower lung area than in the upper lung area. A significant relationship was observed between the %BH-index and respiratory motion distance. Waveforms without steady end-expiration tended to show a high %BH-index. Significant inverse relationships were observed between %BH-index and cycle speed, and between respiratory motion distance and cycle speed. Decrease in SUV max of FB PET/CT was due to tumor size, distribution of lower lung, long respiratory movement at slow breathing cycle speeds, and respiratory waveforms without steady end-expiration. (author)

  14. Imaging with {sup 124}I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    Energy Technology Data Exchange (ETDEWEB)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J. [University of Duisburg-Essen, Medical Faculty, Department of Nuclear Medicine, Essen (Germany); Umutlu, L. [University of Duisburg-Essen, Medical Faculty, Department of Radiology, Essen (Germany)

    2016-06-15

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using {sup 124}I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT{sub 2}) followed by PET/MRI of the neck 24 h after {sup 124}I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT{sub 2} acquisition time (2 min, PET/MRI{sub 2}) and the other covering the whole MRI scan time (30 min, PET/MRI{sub 30}). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI{sub 2} detected significantly more iodine-positive metastases and thyroid remnants than PET/CT{sub 2} (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI{sub 30} tended to detect more PET-positive metastases than PET/MRI{sub 2} (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine

  15. {sup 18}F-FDG PET/contrast enhanced CT in the standard surveillance of high risk colorectal cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Jiménez Londoño, Germán Andrés, E-mail: gjimenez91@yahoo.com [Department of Nuclear Medicine, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); García Vicente, Ana María [Department of Nuclear Medicine, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Sánchez Pérez, Victoria [Department of Oncology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Jiménez Aragón, Fátima [Department of Radiology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); León Martin, Alberto [Investigation Unit, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Cano Cano, Juana María [Department of Oncology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Domínguez Ferreras, Esther [Department of Radiology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Gómez López, Ober Van [Department of Nuclear Medicine, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Espinosa Arranz, Javier [Department of Oncology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Soriano Castrejón, Ángel María [Department of Nuclear Medicine, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain)

    2014-12-15

    Highlights: • We assessed the accuracy of FDG-PET/contrast enhanced CT (FDG-PET/ceCT) in the detection of unsuspected recurrence of colorectal cancer. In regard to our knowledge, no previous experience has been reported about the combined acquisition and interpretation of a FDG-PET/ceCT in the surveillance of colorectal cancer. • We designed a prospective study and performed an individual and combined assessment of both techniques (PET and ceCT), in a patient-based analysis and a lesion-based analysis. • The value of PET and ceCT was found to be similar in the detection of unsuspected recurrence of CRC in a patient-based analysis. The most interesting of our result, is that the combined assessment of PET/ceCT improves the accuracy in the lesion-based analysis. - Abstract: Objective: To assess the accuracy of FDG-PET/contrast enhanced CT (FDG-PET/ceCT) in the detection of unsuspected recurrence of colorectal cancer (CRC) in patients with high risk of relapse. Methods: Thirty-three patients (14 females and 19 males, mean age: 62, range: 41–78), with CRC in complete remission, were prospectively included. All patients underwent FDG-PET/ceCT (58 studies). FDG-PET/ceCT was requested in the surveillance setting, and performed following a standardized protocol. A portal venous phase CT scan was performed after the injection of iodinated contrast agent. An individual and combined assessment of both techniques (PET and ceCT) was performed. Concordant and discordant findings of PET, ceCT and FDG-PET/ceCT were compared in a patient-based and a lesion-based analysis. The final diagnosis, recurrence or disease free status (DFS), were established by histopathology or clinical/radiological follow-up of at least 6 months. Results: Seven out of 33 patients had a confirmed recurrence and the rest of patients had a DFS. In a patient-based analysis the sensitivity and specificity of PET, ceCT and PET/ceCT was of 86% and 88%, 86% and 92%, 86% and 85%, respectively. Attending to

  16. Quality control in PET systems employing 2-D modular detectors

    International Nuclear Information System (INIS)

    Daghighian, F.; Hoffman, E.J.; Huang, S.C.

    1989-01-01

    Many new PET scanner designs employ 2-D detector modules to cost effectively achieve higher image and axial resolution. These systems are potentially less stable than older designs and the loss of a single photomultiplier can disable a large section of a multislice PET system. Because of these factors, it is now necessary to develop more sophisticated quality control procedures that are designed to detect problems as early as possible. The authors have developed and put into operation three automated quality control procedure that are designed to detect problems quickly with a minimum effort on the part of the user. These tests check: (1) stability of the detector modules in terms of efficiency, (2) resolution and its uniformity, (3) the reproducibility of the data

  17. Simple and Reproducible Sample Preparation for Single-Shot Phosphoproteomics with High Sensitivity

    DEFF Research Database (Denmark)

    Jersie-Christensen, Rosa R.; Sultan, Abida; Olsen, Jesper V

    2016-01-01

    The traditional sample preparation workflow for mass spectrometry (MS)-based phosphoproteomics is time consuming and usually requires multiple steps, e.g., lysis, protein precipitation, reduction, alkylation, digestion, fractionation, and phosphopeptide enrichment. Each step can introduce chemical...... artifacts, in vitro protein and peptide modifications, and contaminations. Those often result in sample loss and affect the sensitivity, dynamic range and accuracy of the mass spectrometric analysis. Here we describe a simple and reproducible phosphoproteomics protocol, where lysis, denaturation, reduction......, and alkylation are performed in a single step, thus reducing sample loss and increasing reproducibility. Moreover, unlike standard cell lysis procedures the cell harvesting is performed at high temperatures (99 °C) and without detergents and subsequent need for protein precipitation. Phosphopeptides are enriched...

  18. Click synthesis of PET radiopharmaceuticals

    International Nuclear Information System (INIS)

    Xu Mei; Kuang Chunxiang

    2009-01-01

    Increasing attention has been focused on synthesis radiopharmaceuticals for positron emission tomography (PET). The recent years witnessed applications of click chemistry to PET radiopharmaceutical synthesis,because of its distinctive advantages including high speed,yield and stereospecificity under mild conditions. Synthesis of 18 F-labeled and 11 C-labeled radiopharmaceuticals and intermediates via click chemistry are reviewed. The future trend of click chemistry for the synthesis of PET radiopharmaceutical is prospected. (authors)

  19. qPET - a quantitative extension of the Deauville scale to assess response in interim FDG-PET scans in lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Hasenclever, Dirk [University of Leipzig, Institute for Medical Informatics, Statistics and Epidemiology (IMISE), Leipzig (Germany); Kurch, Lars; Georgi, Thomas; Sabri, Osama; Kluge, Regine [University Hospital Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Mauz-Koerholz, Christine; Koerholz, Dieter [University Hospital Halle, Department of Pediatrics, Halle (Germany); Elsner, Andreas [Hermes Medical Solutions AB, Stockholm (Sweden); Wallace, Hamish [Royal Hospital for Sick Children, Edinburgh, Scotland (United Kingdom); Landman-Parker, Judith [Hopital d' Enfants Armand Trousseau, Paris (France); Moryl-Bujakowska, Angelina [Jagiellonian University Medical College, Department of Pediatric Oncology and Hematology, Polish-American Institute of Pediatrics, Krakow (Poland); Cepelova, Michaela [Department of Pediatric Hematology and Oncology, Faculty Hospital Motol, Prague (Czech Republic); Karlen, Jonas [Karolinska University Hospital, Pediatric Cancer Unit, Astrid Lindgrens Childrens Hospital, Stockholm (Sweden); Alvarez Fernandez-Teijeiro, Ana [University Hospital Virgen Macarena Avda, Department of Pediatric Oncology and Hematology, Sevilla (Spain); Attarbaschi, Andishe [Medical University of Vienna, Department of Pediatric Hematology and Oncology, St. Anna Children' s Hospital, Vienna (Austria); Fossaa, Alexander [Department of Medical Oncology and Radiotherapy, Rikshospitalet - Radiumhospitalet HF, Oslo (Norway); Pears, Jane [Our Lady' s Children' s Hospital, Crumlin, Dublin (Ireland); Hraskova, Andrea [University Children' s Hospital, Clinic of Pediatric Oncology, Bratislava (Slovakia); Bergstraesser, Eva [University Children' s Hospital, Department Oncology, Zurich (Switzerland); Beishuizen, Auke [MC - Sophia Children' s Hospital, Department of Pediatric Oncology/Hematology, Rotterdam (Netherlands); Uyttebroeck, Anne [University Hospitals of Leuven, Department of Pediatric Hemato-Oncology, Leuven (Belgium); Schomerus, Eckhard [University of Odense (OUH), Department of Pediatric Oncology and Hematology, H. C. Andersen Children' s Hospital, Odense (Denmark)

    2014-07-15

    Interim FDG-PET is used for treatment tailoring in lymphoma. Deauville response criteria consist of five ordinal categories based on visual comparison of residual tumor uptake to physiological reference uptakes. However, PET-response is a continuum and visual assessments can be distorted by optical illusions. With a novel semi-automatic quantification tool we eliminate optical illusions and extend the Deauville score to a continuous scale. SUV{sub peak} of residual tumors and average uptake of the liver is measured with standardized volumes of interest. The qPET value is the quotient of these measurements. Deauville scores and qPET-values were determined in 898 pediatric Hodgkin's lymphoma patients after two OEPA chemotherapy cycles. Deauville categories translate to thresholds on the qPET scale: Categories 3, 4, 5 correspond to qPET values of 0.95, 1.3 and 2.0, respectively. The distribution of qPET values is unimodal with a peak representing metabolically normal responses and a tail of clearly abnormal outliers. In our patients, the peak is at qPET = 0.95 coinciding with the border between Deauville 2 and 3. qPET cut values of 1.3 or 2 (determined by fitting mixture models) select abnormal metabolic responses with high sensitivity, respectively, specificity. qPET methodology provides semi-automatic quantification for interim FDG-PET response in lymphoma extending ordinal Deauville scoring to a continuous scale. Deauville categories correspond to certain qPET cut values. Thresholds between normal and abnormal response can be derived from the qPET-distribution without need for follow-up data. In our patients, qPET < 1.3 excludes abnormal response with high sensitivity. (orig.)

  20. qPET - a quantitative extension of the Deauville scale to assess response in interim FDG-PET scans in lymphoma

    International Nuclear Information System (INIS)

    Hasenclever, Dirk; Kurch, Lars; Georgi, Thomas; Sabri, Osama; Kluge, Regine; Mauz-Koerholz, Christine; Koerholz, Dieter; Elsner, Andreas; Wallace, Hamish; Landman-Parker, Judith; Moryl-Bujakowska, Angelina; Cepelova, Michaela; Karlen, Jonas; Alvarez Fernandez-Teijeiro, Ana; Attarbaschi, Andishe; Fossaa, Alexander; Pears, Jane; Hraskova, Andrea; Bergstraesser, Eva; Beishuizen, Auke; Uyttebroeck, Anne; Schomerus, Eckhard

    2014-01-01

    Interim FDG-PET is used for treatment tailoring in lymphoma. Deauville response criteria consist of five ordinal categories based on visual comparison of residual tumor uptake to physiological reference uptakes. However, PET-response is a continuum and visual assessments can be distorted by optical illusions. With a novel semi-automatic quantification tool we eliminate optical illusions and extend the Deauville score to a continuous scale. SUV peak of residual tumors and average uptake of the liver is measured with standardized volumes of interest. The qPET value is the quotient of these measurements. Deauville scores and qPET-values were determined in 898 pediatric Hodgkin's lymphoma patients after two OEPA chemotherapy cycles. Deauville categories translate to thresholds on the qPET scale: Categories 3, 4, 5 correspond to qPET values of 0.95, 1.3 and 2.0, respectively. The distribution of qPET values is unimodal with a peak representing metabolically normal responses and a tail of clearly abnormal outliers. In our patients, the peak is at qPET = 0.95 coinciding with the border between Deauville 2 and 3. qPET cut values of 1.3 or 2 (determined by fitting mixture models) select abnormal metabolic responses with high sensitivity, respectively, specificity. qPET methodology provides semi-automatic quantification for interim FDG-PET response in lymphoma extending ordinal Deauville scoring to a continuous scale. Deauville categories correspond to certain qPET cut values. Thresholds between normal and abnormal response can be derived from the qPET-distribution without need for follow-up data. In our patients, qPET < 1.3 excludes abnormal response with high sensitivity. (orig.)

  1. Feasibility study of a highly sensitive LaBr{sub 3} PET scanner based on the DOI-dependent extended-energy window

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Eiji [Naitonal Institute of Radiological Sciences, Chiba (Japan)], E-mail: rush@nirs.go.jp; Kitamura, Keishi [Shimadzu Corporation, Kyoto (Japan); Nishikido, Fumihiko; Shibuya, Kengo [Naitonal Institute of Radiological Sciences, Chiba (Japan); Hasegawa, Tomoyuki [Kitasato University, Kanagawa (Japan); Yamaya, Taiga; Inadama, Naoko; Murayama, Hideo [Naitonal Institute of Radiological Sciences, Chiba (Japan)

    2009-06-01

    Conventionally, positron emission tomograph (PET) scanners use scintillators which have a high effective atomic number. Recently, novel scintillators like LaBr{sub 3} have been developed which have excellent timing and energy resolutions. LaBr{sub 3} has a high performance for PET scanner use, but its effective atomic number is lower than that of lutetium oxyorthosilicate (LSO). As an alternative, we have developed a scatter reduction method using depth-of-interaction (DOI) information and energy information to increase the sensitivity. The sensitivity of the PET scanner with LaBr{sub 3} can be improved using the DOI-dependent extended-energy window (DEEW) method. In this work, our method is applied to the whole-body LSO/LaBr{sub 3} PET scanner using the GATE simulation toolkit. Simulation results show the number of true coincidences can be increased while minimizing the scatter and random coincidences by using the DEEW method. Noise equivalent count rate (NECR) can be improved by 20-70% for the whole-body DOI-PET scanner. Sensitivity of the PET scanner with a scintillator of low-effective atomic number can be improved by the DEEW method.

  2. Prospective evaluation of 18F-FACBC PET/CT and PET/MRI versus multiparametric MRI in intermediate- to high-risk prostate cancer patients (FLUCIPRO trial).

    Science.gov (United States)

    Jambor, Ivan; Kuisma, Anna; Kähkönen, Esa; Kemppainen, Jukka; Merisaari, Harri; Eskola, Olli; Teuho, Jarmo; Perez, Ileana Montoya; Pesola, Marko; Aronen, Hannu J; Boström, Peter J; Taimen, Pekka; Minn, Heikki

    2018-03-01

    The purpose of this study was to evaluate 18 F-FACBC PET/CT, PET/MRI, and multiparametric MRI (mpMRI) in detection of primary prostate cancer (PCa). Twenty-six men with histologically confirmed PCa underwent PET/CT immediately after injection of 369 ± 10 MBq 18 F-FACBC (fluciclovine) followed by PET/MRI started 55 ± 7 min from injection. Maximum standardized uptake values (SUV max ) were measured for both hybrid PET acquisitions. A separate mpMRI was acquired within a week of the PET scans. Logan plots were used to calculate volume of distribution (V T ). The presence of PCa was estimated in 12 regions with radical prostatectomy findings as ground truth. For each imaging modality, area under the curve (AUC) for detection of PCa was determined to predict diagnostic performance. The clinical trial registration number is NCT02002455. In the visual analysis, 164/312 (53%) regions contained PCa, and 41 tumor foci were identified. PET/CT demonstrated the highest sensitivity at 87% while its specificity was low at 56%. The AUC of both PET/MRI and mpMRI significantly (p PET/CT while no differences were detected between PET/MRI and mpMRI. SUV max and V T of Gleason score (GS) >3 + 4 tumors were significantly (p PET/CT and PET/MRI demonstrated true-positive findings in only 1/7 patients with metastatic lymph nodes. Quantitative 18 F-FACBC imaging significantly correlated with GS but failed to outperform MRI in lesion detection. 18 F-FACBC may assist in targeted biopsies in the setting of hybrid imaging with MRI.

  3. Development of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Yiping; Sun, Xishan [University of Texas MD Anderson Cancer Center (United States); Lou, Kai [Rice University (United States)

    2015-05-18

    It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-scintillator readout, we developed several compact PET detectors suited for PET/MR imaging. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together along all sides to form a large detector panel. Detectors with 1.5x1.5 and 2.0x2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or capacitor-based signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables to dedicated ASIC frontend electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition positioned outside the MRI scanner for coincidence event selection. Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ~18% and 2.8 ns energy and timing resolutions, and around 2-3 mm DOI resolution. A large size detector panel can be scaled up with these modular detectors and different PET systems can be flexibly configured with the scalable readout electronics and data acquisition, providing an important design advantage for different system and application requirements. It is expected that standard shielding of detectors, electronics and signal transfer lines can be applied for simultaneous PET/MR imaging applications, with desired DOI measurement capability to enhance the PET performance and image quality.

  4. Development of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging

    International Nuclear Information System (INIS)

    Shao, Yiping; Sun, Xishan; Lou, Kai

    2015-01-01

    It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-scintillator readout, we developed several compact PET detectors suited for PET/MR imaging. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together along all sides to form a large detector panel. Detectors with 1.5x1.5 and 2.0x2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or capacitor-based signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables to dedicated ASIC frontend electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition positioned outside the MRI scanner for coincidence event selection. Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ~18% and 2.8 ns energy and timing resolutions, and around 2-3 mm DOI resolution. A large size detector panel can be scaled up with these modular detectors and different PET systems can be flexibly configured with the scalable readout electronics and data acquisition, providing an important design advantage for different system and application requirements. It is expected that standard shielding of detectors, electronics and signal transfer lines can be applied for simultaneous PET/MR imaging applications, with desired DOI measurement capability to enhance the PET performance and image quality.

  5. PET/MRI. Challenges, solutions and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Herzog, Hans [Forschungszentrum Juelich (Germany). Inst. of Neuroscience and Medicine - 4

    2012-07-01

    Already from the start of PET/CT integrating positron emission tomography (PET) and computed tomography (CT) in one instrument, there have been considerations how to combine PET and magnetic resonance imaging (MRI) so that their complementary abilities can be utilized in a single investigation. Since classical PET electronics fail in an even weak magnetic field and PET signal processing might disturb high-frequency signals of MRI, it soon became clear that new solutions had to be found to avoid mutual interferences. During the last fifteen years a number of different approaches towards PET/MRI for small animal imaging have been developed by research groups which together with their specific features are summarized in this review. Recently, PET/MRI for human imaging became available as well - this time by industrial initiatives. First some prototypes of BrainPET/MRI were developed followed by commercial products for simultaneous and non-simultaneous whole-body PET/MRI. Although only PET/MRI integrated in one scanner offers the full diversity of complementary multiparametric imaging, there are also promising applications of non-simultaneous sequential PET/MRI. While describing the present instrumentation for human PET/MRI, this review discusses the challenges and promises related to this new imaging technology. (orig.)

  6. Comparison of hybrid {sup 68}Ga-PSMA PET/MRI and {sup 68}Ga-PSMA PET/CT in the evaluation of lymph node and bone metastases of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, Martin T.; Roethke, Matthias; Schlemmer, Heinz-Peter [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Radtke, Jan P. [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); University Hospital Heidelberg, Department of Urology, Heidelberg (Germany); Hadaschik, Boris A. [University Hospital Heidelberg, Department of Urology, Heidelberg (Germany); Kopp-Schneider, A. [German Cancer Research Center, Department of Bioinformatics and Statistics, Heidelberg (Germany); Eder, Matthias; Kopka, Klaus [German Cancer Research Center, Division of Radiopharmaceutical Chemistry, Heidelberg (Germany); Haberkorn, Uwe [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); German Cancer Research Center, Clinical Cooperation Unit Nuclear Medicine, Heidelberg (Germany); Afshar-Oromieh, Ali [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany)

    2016-01-15

    To evaluate the reproducibility of the combination of hybrid PET/MRI and the {sup 68}Ga-PSMA-11 tracer in depicting lymph node (LN) and bone metastases of prostate cancer (PC) in comparison with that of PET/CT. A retrospective analysis of 26 patients who were subjected to {sup 68}Ga-PSMA PET/CT{sub low-dose} (1 h after injection) followed by PET/MRI (3 h after injection) was performed. MRI sequences included T1-w native, T1-w contrast-enhanced, T2-w fat-saturated and diffusion-weighted sequences (DWI{sub b800}). Discordant PET-positive and morphological findings were evaluated. Standardized uptake values (SUV) of PET-positive LNs and bone lesions were quantified and their morphological size and conspicuity determined. Comparing the PET components, the proportion of discordant PSMA-positive suspicious findings was very low (98.5 % of 64 LNs concordant, 100 % of 28 bone lesions concordant). Two PET-positive bone metastases could not be confirmed morphologically using CT{sub low-dose}, but could be confirmed using MRI. In 12 of 20 patients, 47 PET-positive LNs (71.9 %) were smaller than 1 cm in short axis diameter. There were significant linear correlations between PET/MRI SUVs and PET/CT SUVs in the 64 LN metastases (p < 0.0001) and in the 28 osseous metastases (p < 0.0001) for SUV{sub mean} and SUV{sub max}, respectively. The LN SUVs were significantly higher on PET/MRI than on PET/CT (p{sub SUVmax} < 0.0001; p{sub SUVmean} < 0.0001) but there was no significant difference between the bone lesion SUVs (p{sub SUVmax} = 0.495; p{sub SUVmean} = 0.381). Visibility of LNs was significantly higher on MRI using the T1-w contrast-enhanced fat-saturated sequence (p = 0.013), the T2-w fat-saturated sequence (p < 0.0001) and the DWI sequence (p < 0.0001) compared with CT{sub low-dose}. For bone lesions, only the overall conspicuity was higher on MRI compared with CT{sub low-dose} (p < 0.006). Nodal and osseous metastases of PC are accurately and reliably depicted by hybrid PET

  7. Accuracy of a clinical PET/CT vs. a preclinical μPET system for monitoring treatment effects in tumour xenografts

    Energy Technology Data Exchange (ETDEWEB)

    Palmowski, Karin [Department of Experimental Molecular Imaging, RWTH-Aachen University, Aachen (Germany); Department of Pneumology and Critical Care Medicine, Thoraxklinik Heidelberg, University of Heidelberg, Heidelberg (Germany); Winz, Oliver [Department of Nuclear Medicine, RWTH-Aachen University, Aachen (Germany); Rix, Anne; Bzyl, Jessica [Department of Experimental Molecular Imaging, RWTH-Aachen University, Aachen (Germany); Behrendt, Florian F.; Verburg, Frederic A.; Mottaghy, Felix M. [Department of Nuclear Medicine, RWTH-Aachen University, Aachen (Germany); Palmowski, Moritz, E-mail: mpalmowski@ukaachen.de [Department of Experimental Molecular Imaging, RWTH-Aachen University, Aachen (Germany); Department of Nuclear Medicine, RWTH-Aachen University, Aachen (Germany); Academic Radiology Baden Baden, Diagnostic and Interventional Radiology, University Medical Center Heidelberg, Heidelberg (Germany)

    2013-08-15

    Purpose: Small animal imaging is of growing importance for preclinical research and drug development. Tumour xenografts implanted in mice can be visualized with a clinical PET/CT (cPET); however, it is unclear whether early treatment effects can be monitored. Thus, we investigated the accuracy of a cPET versus a preclinical μPET using {sup 18}F-FDG for assessing early treatment effects. Materials and methods: The spatial resolution and the quantitative accuracy of a clinical and preclinical PET were evaluated in phantom experiments. To investigate the sensitivity for assessing treatment response, A431 tumour xenografts were implanted in nude mice. Glucose metabolism was measured in untreated controls and in two therapy groups (either one or four days of antiangiogenic treatment). Data was validated by γ-counting of explanted tissues. Results: In phantom experiments, cPET enabled reliable separation of boreholes ≥ 5 mm whereas μPET visualized boreholes ≥ 2 mm. In animal studies, μPET provided significantly higher tumour-to-muscle ratios for untreated control tumours than cPET (3.41 ± 0.87 vs. 1.60 ± .0.28, respectively; p < 0.01). During treatment, cPET detected significant therapy effects at day 4 (p < 0.05) whereas μPET revealed highly significant therapy effects even at day one (p < 0.01). Correspondingly, γ-counting of explanted tumours indicated significant therapy effects at day one and highly significant treatment response at day 4. Correlation with γ-counting was good for cPET (r = 0.74; p < 0.01) and excellent for μPET (r = 0.85; p < 0.01). Conclusion: Clinical PET is suited to investigate tumour xenografts ≥ 5 mm at an advanced time-point of treatment. For imaging smaller tumours or for the sensitive assessment of very early therapy effects, μPET should be preferred.

  8. WE-G-209-03: PET

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, B. [Mayo Clinic (United States)

    2016-06-15

    Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

  9. WE-G-209-03: PET

    International Nuclear Information System (INIS)

    Kemp, B.

    2016-01-01

    Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

  10. Qualification test of a MPPC-based PET module for future MRI-PET scanners

    Science.gov (United States)

    Kurei, Y.; Kataoka, J.; Kato, T.; Fujita, T.; Funamoto, H.; Tsujikawa, T.; Yamamoto, S.

    2014-11-01

    We have developed a high-resolution, compact Positron Emission Tomography (PET) module for future use in MRI-PET scanners. The module consists of large-area, 4×4 ch MPPC arrays (Hamamatsu S11827-3344MG) optically coupled with Ce:LYSO scintillators fabricated into 12×12 matrices of 1×1 mm2 pixels. At this stage, a pair of module and coincidence circuits was assembled into an experimental prototype gantry arranged in a ring of 90 mm in diameter to form the MPPC-based PET system. The PET detector ring was then positioned around the RF coil of the 4.7 T MRI system. We took an image of a point 22Na source under fast spin echo (FSE) and gradient echo (GE), in order to measure interference between the MPPC-based PET and the MRI. We only found a slight degradation in the spatial resolution of the PET image from 1.63 to 1.70 mm (FWHM; x-direction), or 1.48-1.55 mm (FWHM; y-direction) when operating with the MRI, while the signal-to-noise ratio (SNR) of the MRI image was only degraded by 5%. These results encouraged us to develop a more advanced version of the MRI-PET gantry with eight MPPC-based PET modules, whose detailed design and first qualification test are also presented in this paper.

  11. The effect of 18F-FDG-PET image reconstruction algorithms on the expression of characteristic metabolic brain network in Parkinson's disease.

    Science.gov (United States)

    Tomše, Petra; Jensterle, Luka; Rep, Sebastijan; Grmek, Marko; Zaletel, Katja; Eidelberg, David; Dhawan, Vijay; Ma, Yilong; Trošt, Maja

    2017-09-01

    To evaluate the reproducibility of the expression of Parkinson's Disease Related Pattern (PDRP) across multiple sets of 18F-FDG-PET brain images reconstructed with different reconstruction algorithms. 18F-FDG-PET brain imaging was performed in two independent cohorts of Parkinson's disease (PD) patients and normal controls (NC). Slovenian cohort (20 PD patients, 20 NC) was scanned with Siemens Biograph mCT camera and reconstructed using FBP, FBP+TOF, OSEM, OSEM+TOF, OSEM+PSF and OSEM+PSF+TOF. American Cohort (20 PD patients, 7 NC) was scanned with GE Advance camera and reconstructed using 3DRP, FORE-FBP and FORE-Iterative. Expressions of two previously-validated PDRP patterns (PDRP-Slovenia and PDRP-USA) were calculated. We compared the ability of PDRP to discriminate PD patients from NC, differences and correlation between the corresponding subject scores and ROC analysis results across the different reconstruction algorithms. The expression of PDRP-Slovenia and PDRP-USA networks was significantly elevated in PD patients compared to NC (palgorithms. PDRP expression strongly correlated between all studied algorithms and the reference algorithm (r⩾0.993, palgorithms varied within 0.73 and 0.08 of the reference value for PDRP-Slovenia and PDRP-USA, respectively. ROC analysis confirmed high similarity in sensitivity, specificity and AUC among all studied reconstruction algorithms. These results show that the expression of PDRP is reproducible across a variety of reconstruction algorithms of 18F-FDG-PET brain images. PDRP is capable of providing a robust metabolic biomarker of PD for multicenter 18F-FDG-PET images acquired in the context of differential diagnosis or clinical trials. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  12. The value of FDG-PET/CT in assessing single pulmonary nodules in patients at high risk of lung cancer

    International Nuclear Information System (INIS)

    Kagna, Olga; Solomonov, Anna; Fruchter, Oren; Keidar, Zohar; Bar-Shalom, Rachel; Israel, Ora; Yigla, Mordechai; Guralnik, Luda

    2009-01-01

    To evaluate whether PET/low-dose CT (ldCT) using 18 F-fluorodeoxyglucose (FDG) improves characterization of indeterminate single pulmonary nodules (SPNs) in patients at high risk of lung cancer. Retrospective analysis of 307 patients who underwent FDG-PET/CT for indeterminate SPNs identified 93 (70 men, age range 46-90 years) at high risk of lung cancer (age >40 years, minimum 10 pack-year smokers). SPNs were evaluated for the presence and intensity of FDG avidity and ldCT patterns. The performance of visual and semiquantitative FDG-PET/ldCT algorithms for characterization of SPNs was compared to that of ldCT. Incongruent FDG-PET and ldCT patterns were analyzed for significance in further patient management. Malignancy was diagnosed in 38% patients. FDG avidity defined 33 SPNs as true-positive (TP) and 2 as false-negative (FN) (malignant), and 41 as true-negative (TN) and 17 as false-positive (FP) (benign). For SUVmax of 2.2 (by ROC analysis) there were 27 TP, 8 FN, 48 TN and 10 FP SPNs. LdCT defined 34 TP, 1 FN, 28 TN and 30 FP lesions. Of the FP lesions on ldCT, 60% were FDG-negative. Visual PET/ldCT analysis had a sensitivity of 94%, a specificity of 70%, an accuracy of 80%, a positive predictive value (PPV) of 66%, and a negative predictive value (NPV) of 95% as compared to 77%, 83%, 81%, 73%, 86% for semiquantitative PET/ldCT and 97%, 48%, 66%, 53%, 96% for ldCT, respectively. Both PET/ldCT algorithms had statistically significantly higher specificity and accuracy than ldCT. Semiquantitative analysis showed significantly higher PPV and lower sensitivity and NPV than found with ldCT. A single screening procedure encompassing FDG-PET and ldCT may improve screening for lung cancer in high-risk patients. The significantly improved specificity may potentially reduce FP ldCT results and further unnecessary invasive procedures. (orig.)

  13. Tiny Turtles Purchased at Pet Stores are a Potential High Risk for Salmonella Human Infection in the Valencian Region, Eastern Spain.

    Science.gov (United States)

    Marin, Clara; Vega, Santiago; Marco-Jiménez, Francisco

    2016-07-01

    Turtles may be considered unsafe pets, particularly in households with children. This study aimed to assess Salmonella carriage by turtles in pet stores and in private ownership to inform the public of the potential health risk, enabling informed choices around pet selection. During the period between September and October 2013, 24 pet stores and 96 private owners were sampled in the Valencian Region (Eastern Spain). Salmonella identification procedure was based on ISO 6579: 2002 recommendations (Annex D). Salmonella strains were serotyped in accordance with Kauffman-White-Le-Minor technique. The rate of isolation of Salmonella was very high from pet store samples (75.0% ± 8.8%) and moderate for private owners (29.0% ± 4.6%). Serotyping revealed 18 different serotypes among two Salmonella enterica subspecies: S. enterica subsp. enterica and S. enterica subsp. diarizonae. Most frequently isolated serotypes were Salmonella Typhimurium (39.5%, 17/43) and Salmonella Pomona (9.3%, 4/43). Serotypes identified have previously been reported in turtles, and child Salmonella infections associate with pet turtle exposure. The present study clearly demonstrates that turtles in pet stores, as well as in private owners, could be a direct or indirect source of a high risk of human Salmonella infections. In addition, pet stores should advise their customers of the potential risks associated with reptile ownership.

  14. Quantification of 18F-florbetapir PET: comparison of two analysis methods

    International Nuclear Information System (INIS)

    Hutton, Chloe; Declerck, Jerome; Mintun, Mark A.; Pontecorvo, Michael J.; Devous, Michael D.; Joshi, Abhinay D.

    2015-01-01

    18 F-Florbetapir positron emission tomography (PET) can be used to image amyloid burden in the human brain. A previously developed research method has been shown to have a high test-retest reliability and good correlation between standardized uptake value ratio (SUVR) and amyloid burden at autopsy. The goal of this study was to determine how well SUVRs computed using the research method could be reproduced using an automatic quantification method, developed for clinical use. Two methods for the quantitative analysis of 18 F-florbetapir PET were compared in a diverse clinical population of 604 subjects from the Alzheimer's Disease Neuroimaging Initiative (ADNI) and in a group of 74 younger healthy controls (YHC). Cortex to cerebellum SUVRs were calculated using the research method, which is based on SPM, yielding 'research SUVRs', and using syngo.PET Amyloid Plaque, yielding 'sPAP SUVRs'. Mean cortical SUVRs calculated using the two methods for the 678 subjects were correlated (r = 0.99). Linear regression of sPAP SUVRs on research SUVRs was used to convert the research method SUVR threshold for florbetapir positivity of 1.10 to a corresponding threshold of 1.12 for sPAP. Using the corresponding thresholds, categorization of SUVR values were in agreement between research and sPAP SUVRs for 96.3 % of the ADNI images. SUVRs for all YHC were below the corresponding thresholds. Automatic florbetapir PET quantification using sPAP yielded cortex to cerebellum SUVRs which were correlated and in good agreement with the well-established research method. The research SUVR threshold for florbetapir positivity was reliably converted to a corresponding threshold for sPAP SUVRs. (orig.)

  15. Arterial spin labeling-based Z-maps have high specificity and positive predictive value for neurodegenerative dementia compared to FDG-PET

    Energy Technology Data Exchange (ETDEWEB)

    Faellmar, David; Larsson, Elna-Marie [Uppsala University, Department of Surgical Sciences, Radiology, Uppsala (Sweden); Haller, Sven [Uppsala University, Department of Surgical Sciences, Radiology, Uppsala (Sweden); University Medical Center Freiburg, Department of Neuroradiology, Freiburg (Germany); University of Geneva, Faculty of Medicine, Geneva (Switzerland); Affidea CDRC - Centre Diagnostique Radiologique de Carouge, Carouge (Switzerland); Lilja, Johan [Uppsala University, Department of Surgical Sciences, Nuclear Medicine and PET, Uppsala (Sweden); Hermes Medical Solutions, Stockholm (Sweden); Danfors, Torsten [Uppsala University, Department of Surgical Sciences, Nuclear Medicine and PET, Uppsala (Sweden); Kilander, Lena [Uppsala University, Department of Public Health and Caring Sciences, Geriatrics, Uppsala (Sweden); Tolboom, Nelleke; Croon, Philip M.; Berckel, Bart N.M. van [VU University Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Egger, Karl [University Medical Center Freiburg, Department of Neuroradiology, Freiburg (Germany); Kellner, Elias [Medical Center University of Freiburg, Department of Radiology, Medical Physics, Faculty of Medicine, Freiburg (Germany); Verfaillie, Sander C.J.; Ossenkoppele, Rik [VU University Medical Center, Department of Neurology, Alzheimer Center Amsterdam, Amsterdam (Netherlands); Barkhof, Frederik [VU University Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); UCL, Institutes of Neurology and Healthcare Engineering, London (United Kingdom)

    2017-10-15

    Cerebral perfusion analysis based on arterial spin labeling (ASL) MRI has been proposed as an alternative to FDG-PET in patients with neurodegenerative disease. Z-maps show normal distribution values relating an image to a database of controls. They are routinely used for FDG-PET to demonstrate disease-specific patterns of hypometabolism at the individual level. This study aimed to compare the performance of Z-maps based on ASL to FDG-PET. Data were combined from two separate sites, each cohort consisting of patients with Alzheimer's disease (n = 18 + 7), frontotemporal dementia (n = 12 + 8) and controls (n = 9 + 29). Subjects underwent pseudocontinuous ASL and FDG-PET. Z-maps were created for each subject and modality. Four experienced physicians visually assessed the 166 Z-maps in random order, blinded to modality and diagnosis. Discrimination of patients versus controls using ASL-based Z-maps yielded high specificity (84%) and positive predictive value (80%), but significantly lower sensitivity compared to FDG-PET-based Z-maps (53% vs. 96%, p < 0.001). Among true-positive cases, correct diagnoses were made in 76% (ASL) and 84% (FDG-PET) (p = 0.168). ASL-based Z-maps can be used for visual assessment of neurodegenerative dementia with high specificity and positive predictive value, but with inferior sensitivity compared to FDG-PET. (orig.)

  16. Development of ''Eminence STARGATE'' PET/CT system

    International Nuclear Information System (INIS)

    Okazaki, Masato; Inoue, Yoshihiro; Amano, Masaharu

    2009-01-01

    A PET/CT system, the combination of a PET (Positron Emission Tomography) system with an X-ray CT system, has been widely used in recent years. Our newly developed ''Eminence STARGATE'' PET/CT system allows the PET gantry and the X-ray CT gantry to move independently. This advantage provides high flexibility for PET examination and X-ray CT examination and also eases a patient's psychological anxiety about closed spaces. The system has a 16-slice X-ray CT scanner. (author)

  17. An update on the role of PET/CT and PET/MRI in ovarian cancer

    International Nuclear Information System (INIS)

    Khiewvan, Benjapa; Torigian, Drew A.; Emamzadehfard, Sahra; Paydary, Koosha; Salavati, Ali; Houshmand, Sina; Werner, Thomas J.; Alavi, Abass

    2017-01-01

    This review article summarizes the role of PET/CT and PET/MRI in ovarian cancer. With regard to the diagnosis of ovarian cancer, the presence of FDG uptake within the ovary of a postmenopausal woman raises the concern for ovarian cancer. Multiple studies show that FDG PET/CT can detect lymph node and distant metastasis in ovarian cancer with high accuracy and may, therefore, alter the management to obtain better clinical outcomes. Although PET/CT staging is superior for N and M staging of ovarian cancer, its role is limited for T staging. Additionally, FDG PET/CT is of great benefit in evaluating treatment response and has prognostic value in patients with ovarian cancer. FDG PET/CT also has value to detect recurrent disease, particularly in patients with elevated serum CA-125 levels and negative or inconclusive conventional imaging test results. PET/MRI may beneficial for tumor staging because MRI has higher soft tissue contrast and no ionizing radiation exposure compared to CT. Some non-FDG PET radiotracers such as 18 F-fluorothymidine (FLT) or 11 C-methionine (MET) have been studied in preclinical and clinical studies as well and may play a role in the evaluation of patients with ovarian cancer. (orig.)

  18. An update on the role of PET/CT and PET/MRI in ovarian cancer

    Energy Technology Data Exchange (ETDEWEB)

    Khiewvan, Benjapa [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Mahidol University, Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine Siriraj Hospital, Bangkok (Thailand); Torigian, Drew A.; Emamzadehfard, Sahra; Paydary, Koosha; Salavati, Ali; Houshmand, Sina; Werner, Thomas J.; Alavi, Abass [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States)

    2017-06-15

    This review article summarizes the role of PET/CT and PET/MRI in ovarian cancer. With regard to the diagnosis of ovarian cancer, the presence of FDG uptake within the ovary of a postmenopausal woman raises the concern for ovarian cancer. Multiple studies show that FDG PET/CT can detect lymph node and distant metastasis in ovarian cancer with high accuracy and may, therefore, alter the management to obtain better clinical outcomes. Although PET/CT staging is superior for N and M staging of ovarian cancer, its role is limited for T staging. Additionally, FDG PET/CT is of great benefit in evaluating treatment response and has prognostic value in patients with ovarian cancer. FDG PET/CT also has value to detect recurrent disease, particularly in patients with elevated serum CA-125 levels and negative or inconclusive conventional imaging test results. PET/MRI may beneficial for tumor staging because MRI has higher soft tissue contrast and no ionizing radiation exposure compared to CT. Some non-FDG PET radiotracers such as {sup 18}F-fluorothymidine (FLT) or {sup 11}C-methionine (MET) have been studied in preclinical and clinical studies as well and may play a role in the evaluation of patients with ovarian cancer. (orig.)

  19. MR-based automatic delineation of volumes of interest in human brain PET images using probability maps

    DEFF Research Database (Denmark)

    Svarer, Claus; Madsen, Karina; Hasselbalch, Steen G.

    2005-01-01

    subjects' MR-images, where VOI sets have been defined manually. High-resolution structural MR-images and 5-HT(2A) receptor binding PET-images (in terms of (18)F-altanserin binding) from 10 healthy volunteers and 10 patients with mild cognitive impairment were included for the analysis. A template including...... 35 VOIs was manually delineated on the subjects' MR images. Through a warping algorithm template VOI sets defined from each individual were transferred to the other subjects MR-images and the voxel overlap was compared to the VOI set specifically drawn for that particular individual. Comparisons were...... delineation of the VOI set. The approach was also shown to work equally well in individuals with pronounced cerebral atrophy. Probability-map-based automatic delineation of VOIs is a fast, objective, reproducible, and safe way to assess regional brain values from PET or SPECT scans. In addition, the method...

  20. Dynamic 18F-FET PET in newly diagnosed astrocytic low-grade glioma identifies high-risk patients.

    Science.gov (United States)

    Jansen, Nathalie L; Suchorska, Bogdana; Wenter, Vera; Eigenbrod, Sabina; Schmid-Tannwald, Christine; Zwergal, Andreas; Niyazi, Maximilian; Drexler, Mark; Bartenstein, Peter; Schnell, Oliver; Tonn, Jörg-Christian; Thon, Niklas; Kreth, Friedrich-Wilhelm; la Fougère, Christian

    2014-02-01

    Because the clinical course of low-grade gliomas in the individual adult patient varies considerably and is unpredictable, we investigated the prognostic value of dynamic (18)F-fluorethyltyrosine ((18)F-FET) PET in the early diagnosis of astrocytic low-grade glioma (World Health Organization grade II). Fifty-nine patients with newly diagnosed low-grade glioma and dynamic (18)F-FET PET before histopathologic assessment were retrospectively investigated. (18)F-FET PET analysis comprised a qualitative visual classification of lesions; assessment of the semiquantitative parameters maximal, mean, and total standardized uptake value as ratio to background and biologic tumor volume; and dynamic analysis of intratumoral (18)F-FET uptake over time (increasing vs. decreasing time-activity curves). The correlation between PET parameters and progression-free survival, overall survival, and time to malignant transformation was investigated. (18)F-FET uptake greater than the background level was found in 34 of 59 tumors. Dynamic (18)F-FET uptake analysis was available for 30 of these 34 patients. Increasing and decreasing time-activity curves were found in 18 and 12 patients, respectively. Neither the qualitative factor presence or absence of (18)F-FET uptake nor any of the semiquantitative uptake parameters significantly influenced clinical outcome. In contrast, decreasing time-activity curves in the kinetic analysis were highly prognostic for shorter progression-free survival and time to malignant transformation (P dynamic (18)F-FET PET constitute an unfavorable prognostic factor in astrocytic low-grade glioma and, by identifying high-risk patients, may ease treatment decisions.

  1. Prospective evaluation of solitary thyroid nodule on 18F-FDG PET/CT and high-resolution ultrasonography

    International Nuclear Information System (INIS)

    D'Souza, M.M.; Marwaha, R.K.; Sharma, R.

    2010-01-01

    The utility of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT in the assessment of thyroid nodules is unclear as there are several conflicting reports on the usefulness of standardized uptake value (SUV) as an indicator to distinguish benign from malignant thyroid lesions. This study incorporated an additional parameter, namely dual time point imaging, to determine the diagnostic accuracy of PET/CT imaging. The performance of 18F-FDG PET/CT was compared to that of high-resolution ultrasound which is routinely used for the evaluation of thyroid nodules. Two hundred patients with incidentally detected solitary thyroid nodules were included in the study. Each patient underwent ultrasound and PET/CT evaluation within 7 days of each other, reported by an experienced radiologist and nuclear medicine specialist, respectively, in a blinded manner. The PET/CT criteria employed were maximum SUV (SUV max ) at 60 min and change in SUV max at delayed (120 min) imaging. Final diagnosis was based on pathological evaluation and follow-up. Of the 200 patients, 26 had malignant and 174 had benign nodules. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of ultrasound were 80.8, 81.6, 39.6, 96.6 and 81.5%, respectively. Using SUV max at 60 min as the diagnostic criterion, the above indices were 80.8, 84.5, 43.8, 96.7 and 84%, respectively, for PET/CT. The SUV max of malignant thyroid lesions was significantly higher than benign lesions (16.2±10.6 vs. 4.5±3.1, respectively; p=0.0001). Incorporation of percentage change in SUV max at delayed imaging as the diagnostic criterion yielded a slightly improved sensitivity, specificity, PPV, NPV and accuracy of 84.6, 85.6, 46.8, 97.4 and 85.5%, respectively. There was a significant difference in percentage change in SUV max between malignant and benign thyroid lesions (14.9±11.4 vs. -1.6±13.7, respectively; p=0.0001). However, there was no statistically

  2. PET/CT alignment calibration with a non-radioactive phantom and the intrinsic 176Lu radiation of PET detector

    International Nuclear Information System (INIS)

    Wei, Qingyang; Ma, Tianyu; Wang, Shi; Liu, Yaqiang; Gu, Yu; Dai, Tiantian

    2016-01-01

    Positron emission tomography/computed tomography (PET/CT) is an important tool for clinical studies and pre-clinical researches which provides both functional and anatomical images. To achieve high quality co-registered PET/CT images, alignment calibration of PET and CT scanner is a critical procedure. The existing methods reported use positron source phantoms imaged both by PET and CT scanner and then derive the transformation matrix from the reconstructed images of the two modalities. In this paper, a novel PET/CT alignment calibration method with a non-radioactive phantom and the intrinsic 176 Lu radiation of the PET detector was developed. Firstly, a multi-tungsten-alloy-sphere phantom without positron source was designed and imaged by CT and the PET scanner using intrinsic 176 Lu radiation included in LYSO. Secondly, the centroids of the spheres were derived and matched by an automatic program. Lastly, the rotation matrix and the translation vector were calculated by least-square fitting of the centroid data. The proposed method was employed in an animal PET/CT system (InliView-3000) developed in our lab. Experimental results showed that the proposed method achieves high accuracy and is feasible to replace the conventional positron source based methods.

  3. PET/CT alignment calibration with a non-radioactive phantom and the intrinsic 176Lu radiation of PET detector

    Science.gov (United States)

    Wei, Qingyang; Ma, Tianyu; Wang, Shi; Liu, Yaqiang; Gu, Yu; Dai, Tiantian

    2016-11-01

    Positron emission tomography/computed tomography (PET/CT) is an important tool for clinical studies and pre-clinical researches which provides both functional and anatomical images. To achieve high quality co-registered PET/CT images, alignment calibration of PET and CT scanner is a critical procedure. The existing methods reported use positron source phantoms imaged both by PET and CT scanner and then derive the transformation matrix from the reconstructed images of the two modalities. In this paper, a novel PET/CT alignment calibration method with a non-radioactive phantom and the intrinsic 176Lu radiation of the PET detector was developed. Firstly, a multi-tungsten-alloy-sphere phantom without positron source was designed and imaged by CT and the PET scanner using intrinsic 176Lu radiation included in LYSO. Secondly, the centroids of the spheres were derived and matched by an automatic program. Lastly, the rotation matrix and the translation vector were calculated by least-square fitting of the centroid data. The proposed method was employed in an animal PET/CT system (InliView-3000) developed in our lab. Experimental results showed that the proposed method achieves high accuracy and is feasible to replace the conventional positron source based methods.

  4. Simultaneous PET/MR imaging in a human brain PET/MR system in 50 patients—Current state of image quality

    International Nuclear Information System (INIS)

    Schwenzer, N.F.; Stegger, L.; Bisdas, S.; Schraml, C.; Kolb, A.; Boss, A.; Müller, M.

    2012-01-01

    Objectives: The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. Materials and methods: 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [ 18 F]-FDG, [ 11 C]-methionine or [ 68 Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [ 11 C]-methionine and [ 68 Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. Results: In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27 ± 0.54; FLAIR: 1.38 ± 0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32 ± 0.69; ASL: 1.10 ± 0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [ 11 C]-methionine; additional lesions were found in 2/8 [ 68 Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5 ± 2.2% vs. 0.9 ± 3.6%; mean ratio (frontal/parieto-occipital) 0.93 ± 0.08 vs. 0.96 ± 0.05), respectively. Conclusions: The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance of PET results between PET/MR and PET

  5. Simultaneous PET/MR imaging in a human brain PET/MR system in 50 patients-Current state of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Schwenzer, N.F., E-mail: nina.schwenzer@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Stegger, L., E-mail: stegger@gmx.net [Department of Nuclear Medicine and European Institute for Molecular Imaging, University of Muenster, Muenster (Germany); Bisdas, S., E-mail: sbisdas@gmail.com [Department of Diagnostic and Interventional Neuroradiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Schraml, C., E-mail: christina.schraml@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Kolb, A., E-mail: armin.kolb@med.uni-tuebingen.de [Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Department of Preclinical Imaging and Radiopharmacy, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Boss, A., E-mail: Andreas.Boss@usz.ch [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Institute of Diagnostic and Interventional Radiology, University Hospital Zuerich, Zuerich (Switzerland); Mueller, M., E-mail: mark.mueller@med.uni-tuebingen.de [Department of Nuclear Medicine, Eberhard-Karls University Tuebingen, Tuebingen (Germany); and others

    2012-11-15

    Objectives: The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. Materials and methods: 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [{sup 18}F]-FDG, [{sup 11}C]-methionine or [{sup 68}Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [{sup 11}C]-methionine and [{sup 68}Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. Results: In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27 {+-} 0.54; FLAIR: 1.38 {+-} 0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32 {+-} 0.69; ASL: 1.10 {+-} 0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [{sup 11}C]-methionine; additional lesions were found in 2/8 [{sup 68}Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5 {+-} 2.2% vs. 0.9 {+-} 3.6%; mean ratio (frontal/parieto-occipital) 0.93 {+-} 0.08 vs. 0.96 {+-} 0.05), respectively. Conclusions: The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance

  6. Detection of relevant colonic neoplasms with PET/CT: promising accuracy with minimal CT dose and a standardised PET cut-off

    Energy Technology Data Exchange (ETDEWEB)

    Luboldt, Wolfgang [Multiorgan Screening Foundation, Frankfurt (Germany); University Hospital Frankfurt, Department of Radiology, Frankfurt am Main (Germany); University Hospital Dresden, Clinic and Policlinic of Nuclear Medicine, Dresden (Germany); Volker, Teresa; Zoephel, Klaus; Kotzerke, Joerg [University Hospital Dresden, Clinic and Policlinic of Nuclear Medicine, Dresden (Germany); Wiedemann, Baerbel [University Hospital Dresden, Institute of Medical Informatics and Biometrics, Dresden (Germany); Wehrmann, Ursula [University Hospital Dresden, Clinic and Policlinic of Surgery, Dresden (Germany); Koch, Arne; Abolmaali, Nasreddin [University Hospital Dresden, Oncoray, Dresden (Germany); Toussaint, Todd; Luboldt, Hans-Joachim [Multiorgan Screening Foundation, Frankfurt (Germany); Middendorp, Markus; Gruenwald, Frank [University Hospital Frankfurt, Department of Nuclear Medicine, Frankfurt (Germany); Aust, Daniela [University Hospital Dresden, Department of Pathology, Dresden (Germany); Vogl, Thomas J. [University Hospital Frankfurt, Department of Radiology, Frankfurt am Main (Germany)

    2010-09-15

    To determine the performance of FDG-PET/CT in the detection of relevant colorectal neoplasms (adenomas {>=}10 mm, with high-grade dysplasia, cancer) in relation to CT dose and contrast administration and to find a PET cut-off. 84 patients, who underwent PET/CT and colonoscopy (n=79)/sigmoidoscopy (n=5) for (79 x 6+5 x 2)=484 colonic segments, were included in a retrospective study. The accuracy of low-dose PET/CT in detecting mass-positive segments was evaluated by ROC analysis by two blinded independent reviewers relative to contrast-enhanced PET/CT. On a per-lesion basis characteristic PET values were tested as cut-offs. Low-dose PET/CT and contrast-enhanced PET/CT provide similar accuracies (area under the curve for the average ROC ratings 0.925 vs. 0.929, respectively). PET demonstrated all carcinomas (n=23) and 83% (30/36) of relevant adenomas. In all carcinomas and adenomas with high-grade dysplasia (n=10) the SUV{sub max} was {>=}5. This cut-off resulted in a better per-segment sensitivity and negative predictive value (NPV) than the average PET/CT reviews (sensitivity: 89% vs. 82%; NPV: 99% vs. 98%). All other tested cut-offs were inferior to the SUV{sub max}. FDG-PET/CT provides promising accuracy for colorectal mass detection. Low dose and lack of iodine contrast in the CT component do not impact the accuracy. The PET cut-off SUV{sub max}{>=} 5 improves the accuracy. (orig.)

  7. Detection of relevant colonic neoplasms with PET/CT: promising accuracy with minimal CT dose and a standardised PET cut-off

    International Nuclear Information System (INIS)

    Luboldt, Wolfgang; Volker, Teresa; Zoephel, Klaus; Kotzerke, Joerg; Wiedemann, Baerbel; Wehrmann, Ursula; Koch, Arne; Abolmaali, Nasreddin; Toussaint, Todd; Luboldt, Hans-Joachim; Middendorp, Markus; Gruenwald, Frank; Aust, Daniela; Vogl, Thomas J.

    2010-01-01

    To determine the performance of FDG-PET/CT in the detection of relevant colorectal neoplasms (adenomas ≥10 mm, with high-grade dysplasia, cancer) in relation to CT dose and contrast administration and to find a PET cut-off. 84 patients, who underwent PET/CT and colonoscopy (n=79)/sigmoidoscopy (n=5) for (79 x 6+5 x 2)=484 colonic segments, were included in a retrospective study. The accuracy of low-dose PET/CT in detecting mass-positive segments was evaluated by ROC analysis by two blinded independent reviewers relative to contrast-enhanced PET/CT. On a per-lesion basis characteristic PET values were tested as cut-offs. Low-dose PET/CT and contrast-enhanced PET/CT provide similar accuracies (area under the curve for the average ROC ratings 0.925 vs. 0.929, respectively). PET demonstrated all carcinomas (n=23) and 83% (30/36) of relevant adenomas. In all carcinomas and adenomas with high-grade dysplasia (n=10) the SUV max was ≥5. This cut-off resulted in a better per-segment sensitivity and negative predictive value (NPV) than the average PET/CT reviews (sensitivity: 89% vs. 82%; NPV: 99% vs. 98%). All other tested cut-offs were inferior to the SUV max . FDG-PET/CT provides promising accuracy for colorectal mass detection. Low dose and lack of iodine contrast in the CT component do not impact the accuracy. The PET cut-off SUV max ≥ 5 improves the accuracy. (orig.)

  8. FDG PET and PET-CT for the detection of bone metastases in patients with head and neck cancer. A meta-analysis

    International Nuclear Information System (INIS)

    Yi, Xuelin; Zhang, Hongting; Liu, Shixi; Fan, Min; Liu, Yilin

    2013-01-01

    We performed a meta-analysis to evaluate 18FDG PET/PET-CT for the detection of bone metastases in patients with head and neck cancer. We calculated sensitivities, specificities, likelihood ratios, and constructed summary receiver operating characteristic curves for PET and PET-CT, respectively. We also compared the performance of PET/PET-CT with that of bone scintigraphy by analysing studies that had also used bone scintigraphy on the same patients. Across 9 PET studies (1621 patients) and 10 PET-CT studies (1291 patients), sensitivity and specificity of PET were 0.81 and 0.99, and of PET-CT were 0.89 and 0.99, respectively. In 5 comparative studies (1184 patients), sensitivity and specificity of PET/PET-CT were 0.85 and 0.98, and of bone scintigraphy were 0.55 and 0.98, respectively. 18FDG PET and PET-CT have high sensitivity and accuracy for the detection of bone metastasis in patients with head and neck cancer.

  9. PET motion correction using PRESTO with ITK motion estimation

    Energy Technology Data Exchange (ETDEWEB)

    Botelho, Melissa [Institute of Biophysics and Biomedical Engineering, Science Faculty of University of Lisbon (Portugal); Caldeira, Liliana; Scheins, Juergen [Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich (Germany); Matela, Nuno [Institute of Biophysics and Biomedical Engineering, Science Faculty of University of Lisbon (Portugal); Kops, Elena Rota; Shah, N Jon [Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich (Germany)

    2014-07-29

    The Siemens BrainPET scanner is a hybrid MRI/PET system. PET images are prone to motion artefacts which degrade the image quality. Therefore, motion correction is essential. The library PRESTO converts motion-corrected LORs into highly accurate generic projection data [1], providing high-resolution PET images. ITK is an open-source software used for registering multidimensional data []. ITK provides motion estimation necessary to PRESTO.

  10. PET motion correction using PRESTO with ITK motion estimation

    International Nuclear Information System (INIS)

    Botelho, Melissa; Caldeira, Liliana; Scheins, Juergen; Matela, Nuno; Kops, Elena Rota; Shah, N Jon

    2014-01-01

    The Siemens BrainPET scanner is a hybrid MRI/PET system. PET images are prone to motion artefacts which degrade the image quality. Therefore, motion correction is essential. The library PRESTO converts motion-corrected LORs into highly accurate generic projection data [1], providing high-resolution PET images. ITK is an open-source software used for registering multidimensional data []. ITK provides motion estimation necessary to PRESTO.

  11. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation

    Energy Technology Data Exchange (ETDEWEB)

    Espana, S; Herraiz, J L; Vicente, E; Udias, J M [Grupo de Fisica Nuclear, Departmento de Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid, Madrid (Spain); Vaquero, J J; Desco, M [Unidad de Medicina y CirugIa Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain)], E-mail: jose@nuc2.fis.ucm.es

    2009-03-21

    Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.

  12. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation

    International Nuclear Information System (INIS)

    Espana, S; Herraiz, J L; Vicente, E; Udias, J M; Vaquero, J J; Desco, M

    2009-01-01

    Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.

  13. FDG-PET and FDG-PET/CT for therapy monitoring and restaging in malignant lymphoma

    International Nuclear Information System (INIS)

    Mottaghy, F.M.; Krause, B.J.

    2003-01-01

    F-18-fluorodeoxyglucose (FDG) PET allows to assess residual masses in patients with malignant lymphoma differentiating vital tumor from scar tissue. This approach is not applicable with conventional imaging methods (CDM) such as CT or MRI. On the other hand circumscribed results often cannot be definitely allocated in PET, therefore the combined morphological-biochemical approach using the now available PET/CT systems promises to be a pathbreaking technical progress. There is no doubt that stand alone PET is superior to CDM differentiating residual scar tissue from vital tumor as has been shown in 15 recently published studies. The median sensitivity for detecting active disease with FDG PET across the studies was 91%; the corresponding specificity was 89%. As a result FDG PET had a high negative predictive value of 94%. In contrast, specificity and positive predictive value (PPV) of CDM in the 9 studies were a direct comparison was available were low (31% and 46%, one study 82%). PET positive residual masses were associated with a progression-free survival of 0 - 55%. Only a few studies have included FDG-PET in therapy response monitoring studies, however also these results are promising. At the moment FDG-PET seems to be the best possibility to characterize and qualitatively visualize vitality of tumor masses and also hold promises for efficient therapy response monitoring in patients with malignant lymphoma. Therefore it should be included in standard diagnostic protocols in lymphoma patients. The combined PET/CT has to be ranked superior to conventional PET studies as in many cases the combined structural and functional imaging brings a clearer diagnostic statement. (orig.) [de

  14. Interobserver and Intraobserver Variability among Measurements of FDG PET/CT Parameters in Pulmonary Tumors

    Directory of Open Access Journals (Sweden)

    Gülgün Büyükdereli

    2016-06-01

    Full Text Available Background: 18F-fluorodeoxyglucose (FDG positron emission tomography computed tomography (PET/CT provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV measurements are crucial for cancer treatment monitoring.: 18F-fluorodeoxyglucose (FDG positron emission tomography computed tomography (PET/CT provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV measurements are crucial for cancer treatment monitoring. Aims: The purpose of our study was to assess the variability of these measurements performed by observers evaluating lung tumors. Study Design: Retrospective cross-sectional study. Methods: FDG PET/CT images of 97 patients with pulmonary tumors were independently evaluated by two experienced nuclear medicine physicians. Primary tumor size (UDCT, maximum SUV (SUVmax, mean SUV (SUVmean and maximum SUV normalized to liver mean SUV (SUVnliv max were measured by each observer at two different times with an interval of at least 2 weeks. Interobserver and intraobserver variabilities of measurements were evaluated through statistical methods. Results: Size of the lesions varied from 0.81 to 13.6 cm (mean 4.29±2.24 cm. Very good agreement was shown with correlation, Bland-Altman and regression analysis for all measured PET/CT parameters. In the interobserver and intraobserver variability analysis, the Pearson correlation coefficients were greater than 0.96 and 0.98, respectively. Conclusion: Semi-quantitative measurements of pulmonary tumors were highly reproducible when determined by experienced physicians with clinically available software for routine FDG PET/CT evaluation. Consistency may be improved if the same observer performs serial measurements for any one patient.

  15. Usefulness of {sup 18}F-FDG PET, combined FDG-PET/CT and EUS in diagnosing primary pancreatic carcinoma: A meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Tang Shuang [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127 (China); Huang Gang, E-mail: huang2802@163.com [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127 (China); Liu Jianjun [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127 (China); Liu Tao [Department of Orthopedics, Soochow University, Suzhou (China); Treven, Lyndal [Faculty of Public Health, University of Sydney, Sydney (Australia); Song Saoli; Zhang Chenpeng; Pan Lingling [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127 (China); Zhang Ting [Department of Anesthesiology, Renji Hospital, Shanghai (China)

    2011-04-15

    The aim was to evaluate the diagnostic value of {sup 18}F-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG PET), combined {sup 18}F-fluorodeoxyglucose-positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) and endoscopic ultrasonography (EUS) in diagnosing patients with pancreatic carcinoma. MEDLINE, EMBASE, Cochrane library and some other databases, from January 1966 to April 2009, were searched for initial studies. All the studies published in English or Chinese relating to the diagnostic value of {sup 18}F-FDG PET, PET/CT and EUS for patients with pancreatic cancer were collected. Methodological quality was assessed. The statistic software called 'Meta-Disc 1.4' was used for data analysis. Results: 51 studies were included in this meta-analysis. The pooled sensitivity estimate for combined PET/CT (90.1%) was significantly higher than PET (88.4%) and EUS (81.2%). The pooled specificity estimate for EUS (93.2%) was significantly higher than PET (83.1%) and PET/CT (80.1%). The pooled DOR estimate for EUS (49.774) was significantly higher than PET (32.778) and PET/CT (27.105). SROC curves for PET/CT and EUS showed a little better diagnostic accuracy than PET alone. For PET alone, when interpreted the results with knowledge of other imaging tests, its sensitivity (89.4%) and specificity (80.1%) were closer to PET/CT. For EUS, its diagnostic value decreased in differentiating pancreatic cancer for patients with chronic pancreatitis. In conclusion, PET/CT was a high sensitive and EUS was a high specific modality in diagnosing patients with pancreatic cancer. PET/CT and EUS could play different roles during different conditions in diagnosing pancreatic carcinoma.

  16. Comparison of first pass bolus AIFs extracted from sequential 18F-FDG PET and DSC-MRI of mice

    International Nuclear Information System (INIS)

    Evans, Eleanor; Sawiak, Stephen J.; Ward, Alexander O.; Buonincontri, Guido; Hawkes, Robert C.; Adrian Carpenter, T.

    2014-01-01

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time–activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration–time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and 18 F-FDG respectively to ascertain the technique′s validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies

  17. SmartPET: Applying HPGe and pulse shape analysis to small-animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J. [Department of Physics, University of Liverpool (United Kingdom)], E-mail: rjc@ns.ph.liv.ac.uk; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Grint, A.N.; Mather, A.R.; Nolan, P.J.; Scraggs, D.P.; Turk, G. [Department of Physics, University of Liverpool (United Kingdom); Hall, C.J.; Lazarus, I. [CCLRC Daresbury Laboratory, Warrington, Cheshire (United Kingdom); Berry, A.; Beveridge, T.; Gillam, J.; Lewis, R.A. [School of Physics and Materials Engineering, Monash University, Melbourne (Australia)

    2007-08-21

    The SmartPET project is the development of a prototype small-animal imaging system based on the use of Hyperpure Germanium (HPGe) detectors. The use of digital electronics and application of Pulse Shape Analysis (PSA) techniques provide fine spatial resolution, while the excellent intrinsic energy resolution of HPGe detectors makes the system ideal for multi-nuclide imaging. As a result, the SmartPET system has the potential to function as a dual modality imager, operating as a dual-head Positron Emission Tomography (PET) camera or in a Compton Camera configuration for Single Photon Emission Computed Tomography (SPECT) imaging. In this paper, we discuss how the use of simple PSA techniques greatly improves the position sensitivity of the detector yielding improved spatial resolution in reconstructed images. The PSA methods presented have been validated by comparison to data from high-precision scanning of the detectors. Results from this analysis are presented along with initial images from the SmartPET system, which demonstrates the impact of these techniques on PET images.

  18. Diagnosis and dosimetry in differentiated thyroid carcinoma using 124I PET: comparison of PET/MRI vs PET/CT of the neck

    International Nuclear Information System (INIS)

    Nagarajah, James; Jentzen, Walter; Hartung, Verena; Rosenbaum-Krumme, Sandra; Bockisch, Andreas; Stahl, Alexander; Mikat, Christian; Heusner, Till Alexander; Antoch, Gerald

    2011-01-01

    This study compares intrinsically coregistered 124 I positron emission tomography (PET) and CT (PET/CT) and software coregistered 124 I PET and MRI (PET/MRI) images for the diagnosis and dosimetry of thyroid remnant tissues and lymph node metastases in patients with differentiated thyroid carcinoma (DTC). After thyroidectomy, 33 high-risk DTC patients (stage III or higher) received 124 I PET/CT dosimetry prior to radioiodine therapy to estimate the absorbed dose to lesions and subsequently underwent a contrast-enhanced MRI examination of the neck. Images were evaluated by two experienced nuclear medicine physicians and two radiologists to identify the lesions and to categorize their presumable provenience, i.e. thyroid remnant tissue (TT), lymph node metastasis (LN) and inconclusive tissue. The categorization and dosimetry of lesions was initially performed with PET images alone (PET only). Subsequently lesions were reassessed including the CT and MRI data. The analyses were performed on a patient and on a lesion basis. Patient-based analyses showed that 26 of 33 (79%) patients had at least one lesion categorized as TT on PET only. Of these patients, 11 (42%) and 16 (62%) had a morphological correlate on CT and MRI, respectively, in at least one TT PET lesion. Twelve patients (36%) had at least one lesion classified as LN on PET only. Nine (75%) of these patients had a morphological correlate on both CT and MRI in at least one LN PET lesion. Ten patients (30%) showed at least one lesion on PET only classified as inconclusive. The classification was changed to a clear classification in two patients (two LN) by CT and in four (two TT, two LN) patients by MRI. Lesion-based analyses (n = 105 PET positive lesions) resulted in categorization as TT in 61 cases (58%), 16 (26%) of which had a morphological correlate on CT and 33 (54%) on MRI. A total of 29 lesions (27%) were classified as LN on PET, 18 (62%) of which had a morphological correlate on CT and 24 (83%) on MRI

  19. Separation and recycling of cotton from cotton/PET blends by depolymerization of PET catalyzed by bases and ionic liquids

    NARCIS (Netherlands)

    Bouwhuis, G.H. (Gerrit); Brinks, G.J. (Ger); Groeneveld, R.A.J. (Richard); Oelerich, J. (Jens)

    2014-01-01

    The recycling of post consumer cotton textile waste is highly requested, due to the high environmental impact of cotton production. Often cotton is mixed in blends with polyethylene terephthalate (PET). For the generation of high value products from recycled cotton, it essential that PET is

  20. PET and Recycling

    OpenAIRE

    Funda Sevencan; Songul A. Vaizoglu

    2007-01-01

    This review aims to clarify the need of decreasing the environmental effects caused by human and draw attention to the increasing environmental effects of plastics wastes. Plastics consist of organic molecules with high density molecules or polymers. Main resources of plastics are the residue of oil rafineries. Several advantages of plastics, have increased the usage continuously. Polyethylene Terephthalate (PET) is the most commonly used plastics. PET is used to protect food, drinking water,...

  1. Towards truly integrated hardware fusion with PET/CT

    International Nuclear Information System (INIS)

    Beyer, T.

    2005-01-01

    Combined PET/CT imaging is a non-invasive means of acquiring and reviewing both, the anatomy and the molecular pathways of a patient during a quasi-simultaneous examination. Since the introduction of the prototype PET/CT in 1998 this imaging technology has evolved rapidly. State-of-the-art PET/CT tomographs combine the latest technology in spiral, multi-slice CT and PET using novel scintillator materials and image reconstruction techniques. Together with novel patient positioning systems PET/CT tomographs allow to acquire complementary PET and CT data in a single exam with the best intrinsic co-registration. In addition to the hardware integration efforts have been made to integrate the acquisition and viewing software in PET/CT, thus making the diagnostic review and reporting more efficient. Based on the first clinical experiences and the technical evolution of combined imaging technology PET/CT has become a standard in diagnostic oncology. With high-performance imaging technology at hand today, standardized, high-quality PET/CT imaging protocols are needed to provide best oncology patient care. These protocols mandate the joint efforts of a multi-disciplinary team of physicians, physicists and radiochemists. (orig.)

  2. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Rollo, F.D.; Hines, H.

    2001-01-01

    ADAC Laboratories has two main imaging strengths: PET and Gamma Cameras. PET's three-dimensional imaging of metabolic function is used in oncology, with emerging opportunties in cardiology, genetic mapping and pharmaceuticals research. In oncology, PET imaging can provide comprehensive and accurate staging information which is not available from CT or MRI. In some cases, this information can lead to modification of treatment, for example from an aggressive approach to one of palliation. The SKYLight is the world's first and only gantry-free camera. It is a dual-detector variable angle camera designed for high throughput, with unsurpassed openness and patient access. (orig.)

  3. Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

    CERN Document Server

    Dang, J; Tavernier, S; Lasaygues, P; Mensah, S; Zhang, D C; Auffray, E; Frisch, B; Varela, J; Wan, M X; Felix, N

    2011-01-01

    Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allows labeling the different tissues in the phantom with different concentrations of FDG. The phantom was imaged with a whole-body PET/CT and with the Supersonic Imagine Aixplorer system. This system allows both B-mode US and shear wave elastographic imaging. US elastography is a new imaging method for displaying the tissue elasticity distribution. It was shown to be useful in breast imaging. We also tested the phantom with static elastography. A 6D magnetic positioning system allows fusing the images obtained with the two modalities. ClearPEM-Soni...

  4. Novel geometrical concept of a high-performance brain PET scanner. Principle, design and performance estimates

    International Nuclear Information System (INIS)

    Seguinot, J.; Braem, A.; Chesi, E.

    2006-01-01

    We present the principle, a possible implementation and performance estimates of a novel geometrical concept for a high-resolution positron emission tomograph. The concept, which can be for example implemented in a brain PET device, promises to lead to an essentially parallax-free 3D image reconstruction with excellent spatial resolution and contrast, uniform over the complete field of view. The key components are matrices of long axially oriented scintillator crystals which are read out at both extremities by segmented Hybrid Photon Detectors. We discuss the relevant design considerations for a 3D axial PET camera module, motivate parameter and material choices, and estimate its performance in terms of spatial and energy resolution. We support these estimates by Monte Carlo simulations and in some cases by first experimental results. From the performance of a camera module, we extrapolate to the reconstruction resolution of a 3D axial PET scanner in a semi-analytical way and compare it to an existing state-of-the art brain PET device. We finally describe a dedicated data acquisition system, capable to fully exploit the advantages of the proposed concept

  5. MO-DE-207B-07: Assessment of Reproducibility Of FDG-PET-Based Radiomics Features Across Scanners Using Phantom Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fried, D [University of North Carolina at Chapel Hill, Chapel Hill, NC (United States); Meier, J; Mawlawi, O; Zhou, S; Ibbott, G; Liao, Z; Court, L [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: Use a NEMA-IEC PET phantom to assess the robustness of FDG-PET-based radiomics features to changes in reconstruction parameters across different scanners. Methods: We scanned a NEMA-IEC PET phantom on 3 different scanners (GE Discovery VCT, GE Discovery 710, and Siemens mCT) using a FDG source-to-background ratio of 10:1. Images were retrospectively reconstructed using different iterations (2–3), subsets (21–24), Gaussian filter widths (2, 4, 6mm), and matrix sizes (128,192,256). The 710 and mCT used time-of-flight and point-spread-functions in reconstruction. The axial-image through the center of the 6 active spheres was used for analysis. A region-of-interest containing all spheres was able to simulate a heterogeneous lesion due to partial volume effects. Maximum voxel deviations from all retrospectively reconstructed images (18 per scanner) was compared to our standard clinical protocol. PET Images from 195 non-small cell lung cancer patients were used to compare feature variation. The ratio of a feature’s standard deviation from the patient cohort versus the phantom images was calculated to assess for feature robustness. Results: Across all images, the percentage of voxels differing by <1SUV and <2SUV ranged from 61–92% and 88–99%, respectively. Voxel-voxel similarity decreased when using higher resolution image matrices (192/256 versus 128) and was comparable across scanners. Taking the ratio of patient and phantom feature standard deviation was able to identify features that were not robust to changes in reconstruction parameters (e.g. co-occurrence correlation). Metrics found to be reasonably robust (standard deviation ratios > 3) were observed for routinely used SUV metrics (e.g. SUVmean and SUVmax) as well as some radiomics features (e.g. co-occurrence contrast, co-occurrence energy, standard deviation, and uniformity). Similar standard deviation ratios were observed across scanners. Conclusions: Our method enabled a comparison of

  6. Treatment response evaluation with {sup 18}F-FDG PET/CT and {sup 18}F-NaF PET/CT in multiple myeloma patients undergoing high-dose chemotherapy and autologous stem cell transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Sachpekidis, Christos [German Cancer Research Center (DKFZ), Medical PET Group-Biological Imaging, Clinical Cooperation Unit Nuclear Medicine, Heidelberg (Germany); University of Bern, Department of Nuclear Medicine, Inselspital, Bern University Hospital, Bern (Switzerland); Hillengass, J.; Wagner, B. [University Hospital Heidelberg, Department of Internal Medicine V, Heidelberg (Germany); Goldschmidt, H. [University Hospital Heidelberg, Department of Internal Medicine V, Heidelberg (Germany); National Center for Tumor Diseases (NCT) Heidelberg, Heidelberg (Germany); Haberkorn, U. [German Cancer Research Center (DKFZ), Medical PET Group-Biological Imaging, Clinical Cooperation Unit Nuclear Medicine, Heidelberg (Germany); University of Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Kopka, K. [German Cancer Research Center (DKFZ), Department of Radiopharmaceutical Chemistry, Heidelberg (Germany); Dimitrakopoulou-Strauss, A. [German Cancer Research Center (DKFZ), Medical PET Group-Biological Imaging, Clinical Cooperation Unit Nuclear Medicine, Heidelberg (Germany)

    2017-01-15

    The aim of this study was to assess the combined use of the radiotracers {sup 18}F-FDG and {sup 18}F-NaF in treatment response evaluation of a group of multiple myeloma (MM) patients undergoing high-dose chemotherapy (HDT) followed by autologous stem cell transplantation (ASCT) by means of static (whole-body) and dynamic PET/CT (dPET/CT). Thirty-four patients with primary, previously untreated MM scheduled for treatment with HDT followed by ASCT were enrolled in the study. All patients underwent PET/CT scanning with {sup 18}F-FDG and {sup 18}F-NaF before and after therapy. Treatment response by means of PET/CT was assessed according to the European Organization for Research and Treatment of Cancer (EORTC) 1999 criteria. The evaluation of dPET/CT studies was based on qualitative evaluation, semi-quantitative (SUV) calculation, and quantitative analysis based on two-tissue compartment modelling and a non-compartmental approach leading to the extraction of fractal dimension (FD). An analysis was possible in 29 patients: three with clinical complete response (CR) and 26 with non-CR (13 patients near complete response-nCR, four patients very good partial response-VGPR, nine patients partial response-PR). After treatment, {sup 18}F-FDG PET/CT was negative in 14/29 patients and positive in 15/29 patients, showing a sensitivity of 57.5 % and a specificity of 100 %. According to the EORTC 1999 criteria, {sup 18}F-FDG PET/CT-based treatment response revealed CR in 14 patients ({sup 18}F-FDG PET/CT CR), PR in 11 patients ({sup 18}F-FDG PET/CT PR) and progressive disease in four patients ({sup 18}F-FDG PET/CT PD). In terms of {sup 18}F-NaF PET/CT, 4/29 patients (13.8 %) had a negative baseline scan, thus failed to depict MM. Regarding the patients for which a direct lesion-to-lesion comparison was feasible, {sup 18}F-NaF PET/CT depicted 56 of the 129 {sup 18}F-FDG positive lesions (43 %). Follow-up {sup 18}F-NaF PET/CT showed persistence of 81.5 % of the baseline {sup 18}F

  7. Detection of Cancer with PET and PET/CT in Asymptomatic Volunteers

    International Nuclear Information System (INIS)

    Chung, Ji In; Choi, Joon Young; Lee, Kyung Han; Kim, Byung Tae; Choi, Yoon Ho; Cho, Han Byoul; Shim, Jae Yong

    2009-01-01

    We retrospectively investigated the diagnostic performance of 18 F-fluorodeoxyglucose positron emission tomography (PET) and PET/CT for cancer detection in asymptomatic health-check examinees. This study consisted of 5091 PET or PET/CT conducted as part of annual health examination at one hospital from March 1998 to February 2008. To find the incidence of cancers, medical records of the subjects were thoroughly reviewed for a follow-up period of one year. The patterns of formal readings of PET and PET/CT were analyzed to assess the sensitivity and specificity for cancer detection. The histopathology and stage of the cancers were evaluated in relation to the results of PET. Eighty-six cancers (1.7%) were diagnosed within one year after PET or PET/CT. When PET and PET/CT results were combined, the sensitivity was 48.8% and specificity was 81.1% for cancer detection. PET only had a sensitivity of 46.2% and a specificity of 81.4%, and PET/CT only had a sensitivity of 75.0% and a specificity of 78.5% respectively. There were no significant differences in cancer site, stage and histopathology between PET positive and PET negative cancers. In 19.3% of formal readings of PET and PET/CT, further evaluation to exclude malignancy or significant disease was recommended. Head and neck area and upper gastrointestinal tract were commonly recommended sites for further evaluation. PET and PET/CT showed moderate performance for detecting cancers in asymptomatic adults in this study. More experience and further investigation are needed to overcome limitations of PET and PET/CT for cancer screening

  8. Comparison of 18F-FET PET and perfusion-weighted MRI for glioma grading. A hybrid PET/MR study

    International Nuclear Information System (INIS)

    Verger, Antoine; Filss, Christian P.; Lohmann, Philipp; Stoffels, Gabriele; Rota Kops, Elena; Sabel, Michael; Wittsack, Hans J.; Galldiks, Norbert; Fink, Gereon R.; Shah, Nadim J.; Langen, Karl-Josef

    2017-01-01

    Both perfusion-weighted MR imaging (PWI) and O-(2- 18 F-fluoroethyl)-L-tyrosine PET ( 18 F-FET) provide grading information in cerebral gliomas. The aim of this study was to compare the diagnostic value of 18 F-FET PET and PWI for tumor grading in a series of patients with newly diagnosed, untreated gliomas using an integrated PET/MR scanner. Seventy-two patients with untreated gliomas [22 low-grade gliomas (LGG), and 50 high-grade gliomas (HGG)] were investigated with 18 F-FET PET and PWI using a hybrid PET/MR scanner. After visual inspection of PET and PWI maps (rCBV, rCBF, MTT), volumes of interest (VOIs) with a diameter of 16 mm were centered upon the maximum of abnormality in the tumor area in each modality and the contralateral unaffected hemisphere. Mean and maximum tumor-to-brain ratios (TBR mean , TBR max ) were calculated. In addition, Time-to-Peak (TTP) and slopes of time-activity curves were calculated for 18 F-FET PET. Diagnostic accuracies of 18 F-FET PET and PWI for differentiating low-grade glioma (LGG) from high-grade glioma (HGG) were evaluated by receiver operating characteristic analyses (area under the curve; AUC). The diagnostic accuracy of 18 F-FET PET and PWI to discriminate LGG from HGG was similar with highest AUC values for TBR mean and TBR max of 18 F-FET PET uptake (0.80, 0.83) and for TBR mean and TBR max of rCBV (0.80, 0.81). In case of increased signal in the tumor area with both methods (n = 32), local hot-spots were incongruent in 25 patients (78%) with a mean distance of 10.6 ± 9.5 mm. Dynamic FET PET and combination of different parameters did not further improve diagnostic accuracy. Both 18 F-FET PET and PWI discriminate LGG from HGG with similar diagnostic performance. Regional abnormalities in the tumor area are usually not congruent indicating that tumor grading by 18 F-FET PET and PWI is based on different pathophysiological phenomena. (orig.)

  9. Gamma-camera 18F-FDG PET in diagnosis and staging of patients presenting with suspected lung cancer and comparison with dedicated PET

    DEFF Research Database (Denmark)

    Oturai, Peter S; Mortensen, Jann; Enevoldsen, Henriette

    2004-01-01

    It is not clear whether high-quality coincidence gamma-PET (gPET) cameras can provide clinical data comparable with data obtained with dedicated PET (dPET) cameras in the primary diagnostic work-up of patients with suspected lung cancer. This study focuses on 2 main issues: direct comparison...

  10. Reconstruction of an input function from a dynamic PET water image using multiple tissue curves

    Science.gov (United States)

    Kudomi, Nobuyuki; Maeda, Yukito; Yamamoto, Yuka; Nishiyama, Yoshihiro

    2016-08-01

    Quantification of cerebral blood flow (CBF) is important for the understanding of normal and pathologic brain physiology. When CBF is assessed using PET with {{\\text{H}}2} 15O or C15O2, its calculation requires an arterial input function, which generally requires invasive arterial blood sampling. The aim of the present study was to develop a new technique to reconstruct an image derived input function (IDIF) from a dynamic {{\\text{H}}2} 15O PET image as a completely non-invasive approach. Our technique consisted of using a formula to express the input using tissue curve with rate constant parameter. For multiple tissue curves extracted from the dynamic image, the rate constants were estimated so as to minimize the sum of the differences of the reproduced inputs expressed by the extracted tissue curves. The estimated rates were used to express the inputs and the mean of the estimated inputs was used as an IDIF. The method was tested in human subjects (n  =  29) and was compared to the blood sampling method. Simulation studies were performed to examine the magnitude of potential biases in CBF and to optimize the number of multiple tissue curves used for the input reconstruction. In the PET study, the estimated IDIFs were well reproduced against the measured ones. The difference between the calculated CBF values obtained using the two methods was small as around  PET imaging. This suggests the possibility of using a completely non-invasive technique to assess CBF in patho-physiological studies.

  11. Prospective evaluation of {sup 18}F-FACBC PET/CT and PET/MRI versus multiparametric MRI in intermediate- to high-risk prostate cancer patients (FLUCIPRO trial)

    Energy Technology Data Exchange (ETDEWEB)

    Jambor, Ivan [University of Turku, Department of Diagnostic Radiology, Turku (Finland); University of Massachusetts Medical School - Baystate, Department of Radiology, Springfield, MA (United States); Turku PET Centre, Turku (Finland); Kuisma, Anna [Turku University Hospital, Department of Oncology and Radiotherapy, Turku (Finland); Kaehkoenen, Esa; Bostroem, Peter J. [Turku University Hospital, Department of Urology, Turku (Finland); Kemppainen, Jukka [Turku PET Centre, Turku (Finland); Turku University Hospital, Department of Clinical Physiology and Nuclear Medicine, Turku (Finland); Merisaari, Harri [University of Turku, Department of Diagnostic Radiology, Turku (Finland); Turku PET Centre, Turku (Finland); University of Turku, Department of Information Technology, Turku (Finland); Eskola, Olli; Teuho, Jarmo [Turku PET Centre, Turku (Finland); Montoya Perez, Ileana [University of Turku, Department of Diagnostic Radiology, Turku (Finland); University of Turku, Department of Information Technology, Turku (Finland); Turku University Hospital, Medical Imaging Centre of Southwest Finland, Turku (Finland); Pesola, Marko [University of Turku, Department of Diagnostic Radiology, Turku (Finland); Aronen, Hannu J. [University of Turku, Department of Diagnostic Radiology, Turku (Finland); Turku University Hospital, Medical Imaging Centre of Southwest Finland, Turku (Finland); Taimen, Pekka [University of Turku and Turku University Hospital, Department of Pathology, Turku (Finland); Minn, Heikki [Turku PET Centre, Turku (Finland); Turku University Hospital, Department of Oncology and Radiotherapy, Turku (Finland)

    2018-03-15

    The purpose of this study was to evaluate {sup 18}F-FACBC PET/CT, PET/MRI, and multiparametric MRI (mpMRI) in detection of primary prostate cancer (PCa). Twenty-six men with histologically confirmed PCa underwent PET/CT immediately after injection of 369 ± 10 MBq {sup 18}F-FACBC (fluciclovine) followed by PET/MRI started 55 ± 7 min from injection. Maximum standardized uptake values (SUV{sub max}) were measured for both hybrid PET acquisitions. A separate mpMRI was acquired within a week of the PET scans. Logan plots were used to calculate volume of distribution (V{sub T}). The presence of PCa was estimated in 12 regions with radical prostatectomy findings as ground truth. For each imaging modality, area under the curve (AUC) for detection of PCa was determined to predict diagnostic performance. The clinical trial registration number is NCT02002455. In the visual analysis, 164/312 (53%) regions contained PCa, and 41 tumor foci were identified. PET/CT demonstrated the highest sensitivity at 87% while its specificity was low at 56%. The AUC of both PET/MRI and mpMRI significantly (p < 0.01) outperformed that of PET/CT while no differences were detected between PET/MRI and mpMRI. SUV{sub max} and V{sub T} of Gleason score (GS) >3 + 4 tumors were significantly (p < 0.05) higher than those for GS 3 + 3 and benign hyperplasia. A total of 442 lymph nodes were evaluable for staging, and PET/CT and PET/MRI demonstrated true-positive findings in only 1/7 patients with metastatic lymph nodes. Quantitative {sup 18}F-FACBC imaging significantly correlated with GS but failed to outperform MRI in lesion detection. {sup 18}F-FACBC may assist in targeted biopsies in the setting of hybrid imaging with MRI. (orig.)

  12. PET/CT alignment calibration with a non-radioactive phantom and the intrinsic {sup 176}Lu radiation of PET detector

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Qingyang [School of Automation and Electrical Engineering, University of Science & Technology Beijing, Beijing 100083 (China); Ma, Tianyu; Wang, Shi; Liu, Yaqiang [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Gu, Yu, E-mail: guyu@ustb.edu.cn [School of Automation and Electrical Engineering, University of Science & Technology Beijing, Beijing 100083 (China); Dai, Tiantian, E-mail: maxinedtt@163.com [Department of Radiation Oncology, China-Japan Friendship Hospital, Beijing 100029 (China)

    2016-11-01

    Positron emission tomography/computed tomography (PET/CT) is an important tool for clinical studies and pre-clinical researches which provides both functional and anatomical images. To achieve high quality co-registered PET/CT images, alignment calibration of PET and CT scanner is a critical procedure. The existing methods reported use positron source phantoms imaged both by PET and CT scanner and then derive the transformation matrix from the reconstructed images of the two modalities. In this paper, a novel PET/CT alignment calibration method with a non-radioactive phantom and the intrinsic {sup 176}Lu radiation of the PET detector was developed. Firstly, a multi-tungsten-alloy-sphere phantom without positron source was designed and imaged by CT and the PET scanner using intrinsic {sup 176}Lu radiation included in LYSO. Secondly, the centroids of the spheres were derived and matched by an automatic program. Lastly, the rotation matrix and the translation vector were calculated by least-square fitting of the centroid data. The proposed method was employed in an animal PET/CT system (InliView-3000) developed in our lab. Experimental results showed that the proposed method achieves high accuracy and is feasible to replace the conventional positron source based methods.

  13. Highly reproducible and sensitive silver nanorod array for the rapid detection of Allura Red in candy

    Science.gov (United States)

    Yao, Yue; Wang, Wen; Tian, Kangzhen; Ingram, Whitney Marvella; Cheng, Jie; Qu, Lulu; Li, Haitao; Han, Caiqin

    2018-04-01

    Allura Red (AR) is a highly stable synthetic red azo dye, which is widely used in the food industry to dye food and increase its attraction to consumers. However, the excessive consumption of AR can result in adverse health effects to humans. Therefore, a highly reproducible silver nanorod (AgNR) array was developed for surface enhanced Raman scattering (SERS) detection of AR in candy. The relative standard deviation (RSD) of AgNR substrate obtained from the same batch and different batches were 5.7% and 11.0%, respectively, demonstrating the high reproducibility. Using these highly reproducible AgNR arrays as the SERS substrates, AR was detected successfully, and its characteristic peaks were assigned by the density function theory (DFT) calculation. The limit of detection (LOD) of AR was determined to be 0.05 mg/L with a wide linear range of 0.8-100 mg/L. Furthermore, the AgNR SERS arrays can detect AR directly in different candy samples within 3 min without any complicated pretreatment. These results suggest the AgNR array can be used for rapid and qualitative SERS detection of AR, holding a great promise for expanding SERS application in food safety control field.

  14. PET

    DEFF Research Database (Denmark)

    Mariager, Rasmus Mølgaard; Schmidt, Regin; Heiberg, Morten Rievers

    PET handler om den hemmelige tjenestes arbejde under den kolde krig 1945-1989. Her fortæller Regin Schmidt, Rasmus Mariager og Morten Heiberg om de mest dramatiske og interessante sager fra PET's arkiv. PET er på flere måder en udemokratisk institution, der er sat til at vogte over demokratiet....... Dens virksomhed er skjult for offentligheden, den overvåger borgernes aktiviteter, og den registrerer følsomme personoplysninger. Historien om PET rejser spørgsmålet om, hvad man skal gøre, når befolkningen i et demokrati er kritisk indstillet over for overvågningen af lovlige politiske aktiviteter......, mens myndighederne mener, at det er nødvendigt for at beskytte demokratiet. PET er på en gang en fortælling om konkrete aktioner og begivenheder i PET's arbejde og et stykke Danmarkshistorie. Det handler om overvågning, spioner, politisk ekstremisme og international terrorisme.  ...

  15. High throughput static and dynamic small animal imaging using clinical PET/CT: potential preclinical applications

    International Nuclear Information System (INIS)

    Aide, Nicolas; Desmonts, Cedric; Agostini, Denis; Bardet, Stephane; Bouvard, Gerard; Beauregard, Jean-Mathieu; Roselt, Peter; Neels, Oliver; Beyer, Thomas; Kinross, Kathryn; Hicks, Rodney J.

    2010-01-01

    The objective of the study was to evaluate state-of-the-art clinical PET/CT technology in performing static and dynamic imaging of several mice simultaneously. A mouse-sized phantom was imaged mimicking simultaneous imaging of three mice with computation of recovery coefficients (RCs) and spillover ratios (SORs). Fifteen mice harbouring abdominal or subcutaneous tumours were imaged on clinical PET/CT with point spread function (PSF) reconstruction after injection of [18F]fluorodeoxyglucose or [18F]fluorothymidine. Three of these mice were imaged alone and simultaneously at radial positions -5, 0 and 5 cm. The remaining 12 tumour-bearing mice were imaged in groups of 3 to establish the quantitative accuracy of PET data using ex vivo gamma counting as the reference. Finally, a dynamic scan was performed in three mice simultaneously after the injection of 68 Ga-ethylenediaminetetraacetic acid (EDTA). For typical lesion sizes of 7-8 mm phantom experiments indicated RCs of 0.42 and 0.76 for ordered subsets expectation maximization (OSEM) and PSF reconstruction, respectively. For PSF reconstruction, SOR air and SOR water were 5.3 and 7.5%, respectively. A strong correlation (r 2 = 0.97, p 2 = 0.98; slope = 0.89, p 2 = 0.96; slope = 0.62, p 68 Ga-EDTA dynamic acquisition. New generation clinical PET/CT can be used for simultaneous imaging of multiple small animals in experiments requiring high throughput and where a dedicated small animal PET system is not available. (orig.)

  16. Development of scintillation materials for PET scanners

    CERN Document Server

    Korzhik, Mikhail; Annenkov, Alexander N; Borissevitch, Andrei; Dossovitski, Alexei; Missevitch, Oleg; Lecoq, Paul

    2007-01-01

    The growing demand on PET methodology for a variety of applications ranging from clinical use to fundamental studies triggers research and development of PET scanners providing better spatial resolution and sensitivity. These efforts are primarily focused on the development of advanced PET detector solutions and on the developments of new scintillation materials as well. However Lu containing scintillation materials introduced in the last century such as LSO, LYSO, LuAP, LuYAP crystals still remain the best PET species in spite of the recent developments of bright, fast but relatively low density lanthanum bromide scintillators. At the same time Lu based materials have several drawbacks which are high temperature of crystallization and relatively high cost compared to alkali-halide scintillation materials. Here we describe recent results in the development of new scintillation materials for PET application.

  17. Quantification of {sup 18}F-florbetapir PET: comparison of two analysis methods

    Energy Technology Data Exchange (ETDEWEB)

    Hutton, Chloe; Declerck, Jerome [Siemens Molecular Imaging, Oxford (United Kingdom); Mintun, Mark A.; Pontecorvo, Michael J.; Devous, Michael D.; Joshi, Abhinay D. [Avid Radiopharmaceuticals a wholly owned subsidiary of Eli Lilly and Company, Philadelphia, PA (United States); Collaboration: for the Alzheimer' s Disease Neuroimaging Initiative

    2015-04-01

    {sup 18}F-Florbetapir positron emission tomography (PET) can be used to image amyloid burden in the human brain. A previously developed research method has been shown to have a high test-retest reliability and good correlation between standardized uptake value ratio (SUVR) and amyloid burden at autopsy. The goal of this study was to determine how well SUVRs computed using the research method could be reproduced using an automatic quantification method, developed for clinical use. Two methods for the quantitative analysis of {sup 18}F-florbetapir PET were compared in a diverse clinical population of 604 subjects from the Alzheimer's Disease Neuroimaging Initiative (ADNI) and in a group of 74 younger healthy controls (YHC). Cortex to cerebellum SUVRs were calculated using the research method, which is based on SPM, yielding 'research SUVRs', and using syngo.PET Amyloid Plaque, yielding 'sPAP SUVRs'. Mean cortical SUVRs calculated using the two methods for the 678 subjects were correlated (r = 0.99). Linear regression of sPAP SUVRs on research SUVRs was used to convert the research method SUVR threshold for florbetapir positivity of 1.10 to a corresponding threshold of 1.12 for sPAP. Using the corresponding thresholds, categorization of SUVR values were in agreement between research and sPAP SUVRs for 96.3 % of the ADNI images. SUVRs for all YHC were below the corresponding thresholds. Automatic florbetapir PET quantification using sPAP yielded cortex to cerebellum SUVRs which were correlated and in good agreement with the well-established research method. The research SUVR threshold for florbetapir positivity was reliably converted to a corresponding threshold for sPAP SUVRs. (orig.)

  18. PET in cerebrovascular disease; PET bei zerebrovaskulaeren Erkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Herholz, K. [Neurologische Universitaetsklinik der Univ. Koeln (Germany)]|[Max-Planck-Institut fuer Neurologische Forschung, Koeln (Germany)

    1997-03-01

    Tissue viability is of particular interest in acute cerebral ischemia because it may be preserved if reperfusion can be achieved rapidly, e.g. by acute thrombolysis. Measurements of regional cerebral blood flow (CBF) and oxygen consumption by PET can assess tissue viability, and they have substantially increased our knowledge of th pathophysiology of ischemic stroke and the associated penumbra. Widerspread clinical application in acute stroke, however, is unlikely because of the large logistic and personnel resources required. In chronic cerebrovascular disease, measurement of regional CBF and glucose metabolism, which is usually coupled, provide detailed insights in disturbance of cortical function, e.g. due to deafferentiation, and contribute to differentiation of dementia types. Chronic misery perfusion, i.e. reduced perfusion that does not match the metabolic demand of the tissue, can be demonstrated by PET. It may be found in some patients with high-grade arterial stenoses. Less severe impairment of brain perfusion can be demonstrated by measurement of the cerebrovascular reserve capacity. The most frequent clinical situations can be assessed by less demanding procedures, e.g. by SPECT. In conclusion, PET has its role in cerebrovascular disease primarily within scientific studies, where high resolution and absolute quantitation of physiological variables are essential. (orig.). 65 refs. [Deutsch] Beim akuten ischaemischen Insult ist die Vitalitaet des Gewebes von besonderem Interesse, da sie durch rasche Reperfusion, z.B. durch Thrombolyse, erhalten bleiben kann. Messungen der zerebralen Durchblutung und des Sauerstoffumsatzes mittels PET geben darueber wesentliche Aufschluesse, und sie sind wichtig fuer das Verstaendnis der Pathophysiologie ischaemischer Infarkte und der Penumbra mit kritischer Perfusion beim Menschen. Ihre breitere Anwendung in der klinischen Patientenversorgung kommt allerdings wegen des hohen Aufwandes derzeit kaum in Betracht. Bei

  19. High performance ZnO:Al films deposited on PET substrates using facing target sputtering

    Science.gov (United States)

    Guo, Tingting; Dong, Guobo; Gao, Fangyuan; Xiao, Yu; Chen, Qiang; Diao, Xungang

    2013-10-01

    ZnO:Al (ZAO) thin films have been deposited on flexible PET substrates using a plasma damage-free facing target sputtering system at room temperature. The structure, surface morphology, electrical and optical properties were investigated as a function of working power. All the samples have a highly preferred orientation of the c-axis perpendicular to the PET substrate and have a high quality surface. With increased working power, the carrier concentration changes slightly, the mobility increases at the beginning and decreases after it reaches a maximum value, in line with electrical conductivity. The figure of merit has been significantly improved with increasing of the working power. Under the optimized condition, the lowest resistivity of 1.3 × 10-3 Ω cm with a sheet resistance of 29 Ω/□ and the relative visible transmittance above 93% in the visible region were obtained.

  20. High performance ZnO:Al films deposited on PET substrates using facing target sputtering

    International Nuclear Information System (INIS)

    Guo, Tingting; Dong, Guobo; Gao, Fangyuan; Xiao, Yu; Chen, Qiang; Diao, Xungang

    2013-01-01

    ZnO:Al (ZAO) thin films have been deposited on flexible PET substrates using a plasma damage-free facing target sputtering system at room temperature. The structure, surface morphology, electrical and optical properties were investigated as a function of working power. All the samples have a highly preferred orientation of the c-axis perpendicular to the PET substrate and have a high quality surface. With increased working power, the carrier concentration changes slightly, the mobility increases at the beginning and decreases after it reaches a maximum value, in line with electrical conductivity. The figure of merit has been significantly improved with increasing of the working power. Under the optimized condition, the lowest resistivity of 1.3 × 10 −3 Ω cm with a sheet resistance of 29 Ω/□ and the relative visible transmittance above 93% in the visible region were obtained.

  1. Comparison of first pass bolus AIFs extracted from sequential {sup 18}F-FDG PET and DSC-MRI of mice

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Eleanor, E-mail: ee244@cam.ac.uk [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ (United Kingdom); Sawiak, Stephen J. [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ (United Kingdom); Behavioural and Clinical Neuroscience Institute, Department of Experimental Psychology, University of Cambridge, Cambridge, CB2 3EB (United Kingdom); Ward, Alexander O.; Buonincontri, Guido; Hawkes, Robert C.; Adrian Carpenter, T. [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ (United Kingdom)

    2014-01-11

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time–activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration–time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and {sup 18}F-FDG respectively to ascertain the technique′s validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies.

  2. Clinical usefulness of PET in the management of oral cancer. Comparison between FDG-PET and MET-PET

    International Nuclear Information System (INIS)

    Kitagawa, Yoshimasa; Saitoh, Masaaki; Nakamura, Mikiko

    2007-01-01

    Inductive chemoradiotherapy has played an important role in preserving organs and functions in patients with oral squamous cell carcinoma (SCC). To determine whether a reduced form of surgery should be performed after chemoradiotherapy, accurate evaluation of residual tumor cells is essential. We investigated the clinical value of positron emission tomography with 18 F labeled fluorodeoxyglucose (FDG-PET) in the management of oral SCCs. Forty-five patients underwent two FDG-PET studies, one prior to and one at 6 weeks after the chemoradiotherapy. Pretreatment FDG-PET was useful in predicting the response to treatment. Posttreatment FDG-PET could evaluate residual viable cells and prognosis. Organ preservation may be feasible based on PET evaluation. Hence FDG-PET is a valuable tool in the treatment of oral cancer. 11 C-Methionine (MET) is another promising tracer for PET that can be used to assess metabolic demand for amino acids in cancer cells. A MET-PET and FDG-PET study was performed during the same period to investigate diagnostic accuracy in 40 oral malignancies. Sensitivity and positive predictive value of MET-PET were 95% and 100%, respectively, and were comparable with those of FDG-PET. Further study is required to determine the diagnostic significance of MET-PET in evaluating response to chemoradiotherapy. (author)

  3. Reproducibility of serial peri-ictal single-photon emission tomography difference images in epilepsy patients undergoing surgical resection

    International Nuclear Information System (INIS)

    Avery, R.A.; Studholme, C.; Stokking, R.; Morano, G.; Corsi, M.; Seibyl, J.P.; Zubal, I.G.; Spencer, S.S.; Spencer, D.D.

    2000-01-01

    Peri-ictal single-photon emission tomography (SPET) difference images co-registered to magnetic resonance imaging (MRI) visualize regional cerebral blood flow (rCBF) changes and help localize the epileptogenic area in medically refractory epilepsy. Few reports have examined the reproducibility of SPET difference image results. Epilepsy patients having two peri-ictal and at least one interictal SPET scan who later underwent surgical resection were studied. Localization accuracy of peri-ictal SPET difference images results, interictal electroencephalography (EEG), and ictal EEG from the first (seizure 1) and second (seizure 2) seizure, as well as MRI and positron emission tomography (PET) findings, were compared using surgical resection site as the standard. Thirteen patients underwent surgical resection (11 temporal lobe and 2 extratemporal). SPET results from seizure 1 were localized to the surgical site in 12/13 (92%) patients, while SPET results from seizure 2 were localized in 13/13 (100%) patients. All other modalities were less accurate than the SPET results [interictal EEG - seizure 1 6/13 (46%); ictal EEG - seizure 1 5/13 (38%); interictal intracranial EEG - seizure 2 4/9 (44%); ictal intracranial EEG - seizure 2 results 8/9 (89%); MRI 6/13 (46%); PET 9/13 (69%)]. SPET results were reproducible in 12/13 (92%) patients. SPET difference images calculated from two independent peri-ictal scans appear to be reproducible and accurately localize the epileptogenic area. While SPET difference images visualize many areas of rCBF change, the quantification of these results along with consideration of injection time improves the diagnostic interpretation of the results. (orig.)

  4. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain

    International Nuclear Information System (INIS)

    Jung, Jin Ho; Choi, Yong; Jung, Jiwoong; Kim, Sangsu; Lim, Hyun Keong; Im, Ki Chun; Oh, Chang Hyun; Park, Hyun-wook; Kim, Kyung Min; Kim, Jong Guk

    2015-01-01

    Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was

  5. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jin Ho; Choi, Yong, E-mail: ychoi.image@gmail.com; Jung, Jiwoong; Kim, Sangsu; Lim, Hyun Keong; Im, Ki Chun [Department of Electronic Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul 121-742 (Korea, Republic of); Oh, Chang Hyun; Park, Hyun-wook [Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Kim, Kyung Min; Kim, Jong Guk [Korea Institute of Radiological and Medical Science, 75 Nowon-ro, Nowon-gu, Seoul 139-709 (Korea, Republic of)

    2015-05-15

    Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was

  6. SiliPET: Design of an ultra-high resolution small animal PET scanner based on stacks of semi-conductor detectors

    International Nuclear Information System (INIS)

    Cesca, N.; Auricchio, N.; Di Domenico, G.; Zavattini, G.; Malaguti, R.; Andritschke, R.; Kanbach, G.; Schopper, F.

    2007-01-01

    We studied with Monte Carlo simulations, using the EGSnrc code, a new scanner for small animal positron emission tomography (PET), based on stacks of double-sided semiconductor detectors. Each stack is composed of planar detectors with dimension 70x60x1 mm 3 and orthogonal strips on both sides with 500 μm pitch to read the two interaction coordinates, the third being the detector number in the stack. Multiple interactions in a stack are discarded. In this way, we achieve a precise determination of the first interaction point of the two 511 keV photons. The reduced dimensions of the scanner also improve the solid angle coverage resulting in a high sensitivity. Preliminary results of scanners based on Si planar detectors are presented and the initial tomographic reconstructions demonstrate very good spatial resolution limited only by the positron range. This suggests that, this is a promising new approach for small animal PET imaging. We are testing some double-sided silicon detectors, equipped with 128 orthogonal p and n strips on opposite sides using VATAGP3 ASIC by IDEAS

  7. Evaluation of attenuation correction in cardiac PET using PET/MR.

    Science.gov (United States)

    Lau, Jeffrey M C; Laforest, R; Sotoudeh, H; Nie, X; Sharma, S; McConathy, J; Novak, E; Priatna, A; Gropler, R J; Woodard, P K

    2017-06-01

    Simultaneous acquisition Positron emission tomography/magnetic resonance (PET/MR) is a new technology that has potential as a tool both in research and clinical diagnosis. However, cardiac PET acquisition has not yet been validated using MR imaging for attenuation correction (AC). The goal of this study is to evaluate the feasibility of PET imaging using a standard 2-point Dixon volume interpolated breathhold examination (VIBE) MR sequence for AC. Evaluation was performed in both phantom and patient data. A chest phantom containing heart, lungs, and a lesion insert was scanned by both PET/MR and PET/CT. In addition, 30 patients underwent whole-body 18 F-fluorodeoxyglucose PET/CT followed by simultaneous cardiac PET/MR. Phantom study showed 3% reduction of activity values in the myocardium due to the non-inclusion of the phased array coil in the AC. In patient scans, average standardized uptake values (SUVs) obtained by PET/CT and PET/MR showed no significant difference (n = 30, 4.6 ± 3.5 vs 4.7 ± 2.8, P = 0.47). There was excellent per patient correlation between the values acquired by PET/CT and PET/MR (R 2  = 0.97). Myocardial SUVs PET imaging using MR for AC shows excellent correlation with myocardial SUVs obtained by standard PET/CT imaging. The 2-point Dixon VIBE MR technique can be used for AC in simultaneous PET/MR data acquisition.

  8. PET-CT and PET-MRI of the prostate. From {sup 18}F-FDG to {sup 68}Ga-PSMA; PET-CT/-MRT der Prostata. Von {sup 18}F-FDG zu {sup 68}Ga-PSMA

    Energy Technology Data Exchange (ETDEWEB)

    Knorr, K.; Eiber, M.; Scheidhauer, K. [Technische Universitaet Muenchen, Nuklearmedizinische Klinik und Poliklinik, Klinikum rechts der Isar, Muenchen (Germany); Maurer, T. [Technische Universitaet Muenchen, Urologische Klinik und Poliklinik, Klinikum rechts der Isar, Muenchen (Germany); Wester, H.J. [Technische Universitaet Muenchen, Pharmazeutische Radiochemie, Garching (Germany)

    2017-08-15

    In the last few years nuclear medical diagnostics have experienced a unprecedented renaissance in the diagnostics of prostate cancer, due to the availability of hybrid imaging with positron emission tomography computed tomography (PET/CT), PET magnetic resonance imaging (PET/MRI) and single photon emission computed tomography (SPECT) CT as well as the development of prostate-specific radiopharmaceuticals. The use of fluorodeoxyglucose (FDG), which has been successfully implemented for many years in PET diagnostics, is only helpful in dedifferentiated tumors due to the biological characteristics of prostate cancer. New specific radiopharmaceuticals, such as choline-derivatives, which are incorporated into the prostate cancer cell and built into the cell membrane as well as the recently developed highly specific ligands for prostate-specific membrane antigen (PSMA) are revolutionizing prostate cancer imaging and (re-) staging. The {sup 68} Ga-labeled PSMA ligands for PET-CT and PET-MRI are highly specific tracers for primary diagnostics and detection of metastases of prostate carcinoma. In risk patients, which includes patients with intermediate and high-risk tumors, they have largely replaced choline-based PET-CT, especially in the case of very low PSA values <0.5 ng/ml in the diagnostics of recurrence. The use in the primary diagnostics as PET-MRI, also in combination with multiparametric MRI (mpMRI), is promising with respect to early diagnostics and image fusion-assisted biopsy as well as surgery and irradiation planning. (orig.) [German] Die nuklearmedizinische Diagnostik hat in den letzten Jahren bei der Bildgebung des Prostatakarzinoms eine rasante Entwicklung erlebt, sowohl aufgrund der verfuegbaren Hybridbildgebung mit der Positronenemissionstomographie(PET)-CT, PET-MRT sowie der Single-photon-emission-computed-tomography(SPECT)-CT als auch durch die Entwicklung prostataspezifischer Radiopharmaka. Die in der PET-Diagnostik seit Jahren erfolgreich eingesetzte

  9. High-resolution dynamic imaging and quantitative analysis of lung cancer xenografts in nude mice using clinical PET/CT.

    Science.gov (United States)

    Wang, Ying Yi; Wang, Kai; Xu, Zuo Yu; Song, Yan; Wang, Chu Nan; Zhang, Chong Qing; Sun, Xi Lin; Shen, Bao Zhong

    2017-08-08

    Considering the general application of dedicated small-animal positron emission tomography/computed tomography is limited, an acceptable alternative in many situations might be clinical PET/CT. To estimate the feasibility of using clinical PET/CT with [F-18]-fluoro-2-deoxy-D-glucose for high-resolution dynamic imaging and quantitative analysis of cancer xenografts in nude mice. Dynamic clinical PET/CT scans were performed on xenografts for 60 min after injection with [F-18]-fluoro-2-deoxy-D-glucose. Scans were reconstructed with or without SharpIR method in two phases. And mice were sacrificed to extracting major organs and tumors, using ex vivo γ-counting as a reference. Strikingly, we observed that the image quality and the correlation between the all quantitive data from clinical PET/CT and the ex vivo counting was better with the SharpIR reconstructions than without. Our data demonstrate that clinical PET/CT scanner with SharpIR reconstruction is a valuable tool for imaging small animals in preclinical cancer research, offering dynamic imaging parameters, good image quality and accurate data quatification.

  10. Fusion of PET and MRI for Hybrid Imaging

    Science.gov (United States)

    Cho, Zang-Hee; Son, Young-Don; Kim, Young-Bo; Yoo, Seung-Schik

    Recently, the development of the fusion PET-MRI system has been actively studied to meet the increasing demand for integrated molecular and anatomical imaging. MRI can provide detailed anatomical information on the brain, such as the locations of gray and white matter, blood vessels, axonal tracts with high resolution, while PET can measure molecular and genetic information, such as glucose metabolism, neurotransmitter-neuroreceptor binding and affinity, protein-protein interactions, and gene trafficking among biological tissues. State-of-the-art MRI systems, such as the 7.0 T whole-body MRI, now can visualize super-fine structures including neuronal bundles in the pons, fine blood vessels (such as lenticulostriate arteries) without invasive contrast agents, in vivo hippocampal substructures, and substantia nigra with excellent image contrast. High-resolution PET, known as High-Resolution Research Tomograph (HRRT), is a brain-dedicated system capable of imaging minute changes of chemicals, such as neurotransmitters and -receptors, with high spatial resolution and sensitivity. The synergistic power of the two, i.e., ultra high-resolution anatomical information offered by a 7.0 T MRI system combined with the high-sensitivity molecular information offered by HRRT-PET, will significantly elevate the level of our current understanding of the human brain, one of the most delicate, complex, and mysterious biological organs. This chapter introduces MRI, PET, and PET-MRI fusion system, and its algorithms are discussed in detail.

  11. PET or PET-CT with cancer screening

    International Nuclear Information System (INIS)

    Wang Taisong; Zhao Jinhua; Song Jianhua

    2007-01-01

    At present, cancer screening remains a lot of debate in contemporary medical practice. Many constitutes have done a lot of experiments in cancer screening. The same version is that recommendations and decisions regarding cancer screening should be based on reliable data, not self- approbation. Now, some institutes advocate 18 F-FDG PET or 18 F-FDG PET-CT for cancer screening, here, discussed status quo, potential financial, radiation safety and statistical data in 18 F-FDG PET or 18 F-FDG PET- CT cancer screening. (authors)

  12. PET / MRI vs. PET / CT. Indications Oncology

    International Nuclear Information System (INIS)

    Oliva González, Juan P.

    2016-01-01

    Hybrid techniques in Nuclear Medicine is currently a field in full development for diagnosis and treatment of various medical conditions. With the recent advent of PET / MRI much it speculated about whether or not it is superior to PET / CT especially in oncology. The Conference seeks to clarify this situation by dealing issues such as: State of the art technology PET / MRI; Indications Oncology; Some clinical cases. It concludes by explaining the oncological indications of both the real and current situation of the PET / MRI. (author)

  13. PET/CT. Dose-escalated image fusion?

    International Nuclear Information System (INIS)

    Brix, G.; Beyer, T.

    2005-01-01

    Clinical studies demonstrate a gain in diagnostic accuracy by employing combined PET/CT instead of separate CT and PET imaging. However, whole-body PET/CT examinations result in a comparatively high radiation burden to patients and thus require a proper justification and optimization to avoid repeated exposure or over-exposure of patients. This review article summarizes relevant data concerning radiation exposure of patients resulting from the different components of a combined PET/CT examination and presents different imaging strategies that can help to balance the diagnostic needs and the radiation protection requirements. In addition various dose reduction measures are discussed, some of which can be adopted from CT practice, while others mandate modifications to the existing hard- and software of PET/CT systems. (orig.)

  14. PET-MRI and multimodal cancer imaging

    International Nuclear Information System (INIS)

    Wang Taisong; Zhao Jinhua; Song Jianhua

    2011-01-01

    Multimodality imaging, specifically PET-CT, brought a new perspective into the fields of clinical imaging. Clinical cases have shown that PET-CT has great value in clinical diagnosis and experimental research. But PET-CT still bears some limitations. A major drawback is that CT provides only limited soft tissue contrast and exposes the patient to a significant radiation dose. MRI overcome these limitations, it has excellent soft tissue contrast, high temporal and spatial resolution and no radiation damage. Additionally, since MRI provides also functional information, PET-MRI will show a new direction of multimodality imaging in the future. (authors)

  15. Statistical dynamic image reconstruction in state-of-the-art high-resolution PET

    International Nuclear Information System (INIS)

    Rahmim, Arman; Cheng, J-C; Blinder, Stephan; Camborde, Maurie-Laure; Sossi, Vesna

    2005-01-01

    Modern high-resolution PET is now more than ever in need of scrutiny into the nature and limitations of the imaging modality itself as well as image reconstruction techniques. In this work, we have reviewed, analysed and addressed the following three considerations within the particular context of state-of-the-art dynamic PET imaging: (i) the typical average numbers of events per line-of-response (LOR) are now (much) less than unity (ii) due to the physical and biological decay of the activity distribution, one requires robust and efficient reconstruction algorithms applicable to a wide range of statistics and (iii) the computational considerations in dynamic imaging are much enhanced (i.e., more frames to be stored and reconstructed). Within the framework of statistical image reconstruction, we have argued theoretically and shown experimentally that the sinogram non-negativity constraint (when using the delayed-coincidence and/or scatter-subtraction techniques) is especially expected to result in an overestimation bias. Subsequently, two schemes are considered: (a) subtraction techniques in which an image non-negativity constraint has been imposed and (b) implementation of random and scatter estimates inside the reconstruction algorithms, thus enabling direct processing of Poisson-distributed prompts. Both techniques are able to remove the aforementioned bias, while the latter, being better conditioned theoretically, is able to exhibit superior noise characteristics. We have also elaborated upon and verified the applicability of the accelerated list-mode image reconstruction method as a powerful solution for accurate, robust and efficient dynamic reconstructions of high-resolution data (as well as a number of additional benefits in the context of state-of-the-art PET)

  16. [68Ga]Pentixafor-PET/MRI for the detection of Chemokine receptor 4 expression in atherosclerotic plaques

    International Nuclear Information System (INIS)

    Li, Xiang; Heber, Daniel; Leike, Tatjana; Hacker, Marcus; Haug, Alexander R.; Beitzke, Dietrich; Loewe, Christian; Lu, Xia; Zhang, Xiaoli; Wei, Yongxiang; Mitterhauser, Markus; Wadsak, Wolfgang; Kropf, Saskia; Wester, Hans J.

    2018-01-01

    The expression of chemokine receptor type 4 (CXCR4) was found co-localized with macrophages on the atherosclerotic vessel wall and participated in the initial emigration of leukocytes. Gallium-68 [ 68 Ga]Pentixafor has recently been introduced for the imaging of atherosclerosis by targeting CXCR4. We sought to evaluate human atherosclerotic lesions using [ 68 Ga]Pentixafor PET/MRI. Thirty-eight oncology patients underwent [ 68 Ga]Pentixafor PET/MR imaging at baseline. Maximum standardized uptake values (SUV max ) were derived from hot lesions in seven arterial segments and target-to-blood ratios (TBR) were calculated. ANOVA post-hoc and paired t test were performed for statistical comparison, Spearman's correlation coefficient between uptake ratios and cardiovascular risk factors were assessed. The reproducibility of [ 68 Ga]Pentixafor PET/MRI was assessed in seven patients with a follow-up examination by Pearson's regression and Bland-Altman plots analysis. Thirty-four of 38 patients showed 611 focal [ 68 Ga]Pentixafor uptake that followed the contours of the large arteries. Both prevalence and mean TBR max were highest in the descending aorta. There were significantly higher TBR values found in men (1.9 ± 0.3) as compared to women (1.7 ± 0.2; p < 0.05). Patients with mean TBR max > 1.7 showed a significantly higher incidence of diabetes, hypertension hypercholesterolemia and history of cardiovascular disease than patients with mean TBR max ≤ 1.7. [ 68 Ga]Pentixafor uptake showed a good reproducibility (r = 0.6, p < 0.01), and there was no difference between the mean TBR max values of plaque lesions (TBR baseline 1.8 ± 0.3 vs TBR follow-up 1.8 ± 0.3) (p = 0.9). Patients with high arterial uptake showed increased incidence of cardiovascular risk factors, suggesting a potential role of [ 68 Ga]Pentixafor in characterization of atherosclerosis. (orig.)

  17. Reliability of semiquantitative 18F-FDG PET parameters derived from simultaneous brain PET/MRI: A feasibility study

    International Nuclear Information System (INIS)

    Jena, Amarnath; Taneja, Sangeeta; Goel, Reema; Renjen, Pushpendranath; Negi, Pradeep

    2014-01-01

    Purpose: Simultaneous brain PET/MRI faces an important issue of validation of accurate MRI based attenuation correction (AC) method for precise quantitation of brain PET data unlike in PET/CT systems where the use of standard, validated CT based AC is routinely available. The aim of this study was to investigate the feasibility of evaluation of semiquantitative 18 F-FDG PET parameters derived from simultaneous brain PET/MRI using ultrashort echo time (UTE) sequences for AC and to assess their agreement with those obtained from PET/CT examination. Methods: Sixteen patients (age range 18–73 years; mean age 49.43 (19.3) years; 13 men 3 women) underwent simultaneous brain PET/MRI followed immediately by PET/CT. Quantitative analysis of brain PET images obtained from both studies was undertaken using Scenium v.1 brain analysis software package. Twenty ROIs for various brain regions were system generated and 6 semiquantitative parameters including maximum standardized uptake value (SUV max), SUV mean, minimum SUV (SUV min), minimum standard deviation (SD min), maximum SD (SD max) and SD from mean were calculated for both sets of PET data for each patient. Intra-class correlation coefficients (ICCs) were determined to assess agreement between the various semiquantitative parameters for the two PET data sets. Results: Intra-class co-relation between the two PET data sets for SUV max, SUV mean and SD max was highly significant (p < 0.00) for all the 20 predefined brain regions with ICC > 0.9. SD from mean was also found to be statistically significant for all the predefined brain regions with ICC > 0.8. However, SUV max and SUV mean values obtained from PET/MRI were significantly lower compared to those of PET/CT for all the predefined brain regions. Conclusion: PET quantitation accuracy using the MRI based UTE sequences for AC in simultaneous brain PET/MRI is reliable in a clinical setting, being similar to that obtained using PET/CT

  18. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  19. Variability in {sup 18}F-FDG PET/CT methodology of acquisition, reconstruction and analysis for oncologic imaging: state survey; Variabilidade metodologica na aquisicao, reconstrucao e analise de estudos de PET/CT oncologico com FDG-{sup 18}F: levantamento estadual

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Andreia C.F. da S.; Druzian, Aline C.; Pianta, Diego B.; Bacelar, Alexandre, E-mail: acfischer@hcpa.edu.br [Hospital de Clinicas de Porto Alegre, RS (Brazil); Silva, Ana M. Marques da [Pontificia Universidade Catolica do Rio Grande do Sul (NIMed/PUC-RS), Porto Alegre, RS (Brazil). Faculdade de Fisica. Nucleo de Pesquisas em Imagens Medicas

    2016-07-01

    The SUV in {sup 18}F-FDG PET/CT oncological imaging is useful for cancer diagnosis, staging and treatment assessment. There are, however, several factors that can give rise to bias in SUV measurements. When using SUV as a diagnostic tool, one needs to minimize the variability in this measurement by standardization of patient preparation, acquisition and reconstruction parameters. The aim of this study is to evaluate the methodological variability in PET/CT acquisition in Rio Grande do Sul State. For that, in each department, a questionnaire was applied to survey technical information from PET/CT systems and about the acquisitions and analysis methods utilized. All departments implement quality assurance programs consistent with (inter)national recommendations. However, the acquisition and reconstruction methods of acquired PET data differ. The implementation of a harmonized strategy for quantifying the SUV is suggested, in order to obtain greater reproducibility and repeatability. (author)

  20. Quantitative assessment of human and pet exposure to Salmonella associated with dry pet foods.

    Science.gov (United States)

    Lambertini, Elisabetta; Buchanan, Robert L; Narrod, Clare; Ford, Randall M; Baker, Robert C; Pradhan, Abani K

    2016-01-04

    Recent Salmonella outbreaks associated with dry pet foods and treats highlight the importance of these foods as previously overlooked exposure vehicles for both pets and humans. In the last decade efforts have been made to raise the safety of this class of products, for instance by upgrading production equipment, cleaning protocols, and finished product testing. However, no comprehensive or quantitative risk profile is available for pet foods, thus limiting the ability to establish safety standards and assess the effectiveness of current and proposed Salmonella control measures. This study sought to develop an ingredients-to-consumer quantitative microbial exposure assessment model to: 1) estimate pet and human exposure to Salmonella via dry pet food, and 2) assess the impact of industry and household-level mitigation strategies on exposure. Data on prevalence and concentration of Salmonella in pet food ingredients, production process parameters, bacterial ecology, and contact transfer in the household were obtained through literature review, industry data, and targeted research. A probabilistic Monte Carlo modeling framework was developed to simulate the production process and basic household exposure routes. Under the range of assumptions adopted in this model, human exposure due to handling pet food is null to minimal if contamination occurs exclusively before extrusion. Exposure increases considerably if recontamination occurs post-extrusion during coating with fat, although mean ingested doses remain modest even at high fat contamination levels, due to the low percent of fat in the finished product. Exposure is highly variable, with the distribution of doses ingested by adult pet owners spanning 3Log CFU per exposure event. Child exposure due to ingestion of 1g of pet food leads to significantly higher doses than adult doses associated with handling the food. Recontamination after extrusion and coating, e.g., via dust or equipment surfaces, may also lead to

  1. Image interpretation criteria for FDG PET/CT in multiple myeloma: a new proposal from an Italian expert panel. IMPeTUs (Italian Myeloma criteria for PET USe)

    Energy Technology Data Exchange (ETDEWEB)

    Nanni, Cristina; Rambaldi, Ilaria; Fanti, Stefano [AOU Policlinico S. Orsola-Malpighi, Nuclear Medicine, Bologna (Italy); Zamagni, Elena; Cavo, Michele [AOU Policlinico S. Orsola-Malpighi, Hematology, Bologna (Italy); Versari, Annibale [IRCSS, Nuclear Medicine, S. Maria Nuova Hospital, Reggio Emilia (Italy); Chauvie, Stephane [Santa Croce e Carle Hospital, Medical Physics Unit, Cuneo (Italy); Bianchi, Andrea [Santa Croce e Carle Hospital, Nuclear Medicine, Cuneo (Italy); Rensi, Marco [AOU S.Maria della Misericordia, Nuclear Medicine, Udine (Italy); Bello, Marilena [AO Citta della Salute e della Scienza, Nuclear Medicine, Torino (Italy); Gallamini, Andrea [A Lacassagne Cancer Center, Research and Innovation Department, Nice (France); Patriarca, Francesca [Udine University, Hematologic Clinic, Udine (Italy); Gay, Francesca [University of Torino, Myeloma Unit, Division of Hematology, Torino (Italy); Gamberi, Barbara [IRCCS, Hematology Unit, Azienda Ospedaliera ASMN, Reggio Emilia (Italy)

    2016-03-15

    FDG PET/CT is able to detect active disease in patients with multiple myeloma (MM) and can be helpful for staging and assessing therapy response, but no standard interpretation criteria have been proposed for the evaluation of FDG PET/CT in MM. A group of Italian nuclear medicine physicians and haematologists met to propose new visual interpretation criteria to standardize FDG PET/CT evaluation in MM patients (Italian Myeloma criteria for PET USe; IMPeTUs) and the reproducibility of these criteria was tested. This Italian multicentre protocol was set up as a subprotocol of EMN02, an international prospective multicentre trial of the European Myeloma Network. The criteria were agreed at multidisciplinary consensus meetings. They include a description of the metabolic state of the bone marrow (BM), number and site of focal PET-positive lesions, the number of osteolytic lesions, and the presence and site of extramedullary disease, paramedullary disease and fractures. A visual degree of uptake was defined for the target lesion and extramedullary lesions according to modified Deauville criteria. MM patients who had undergone FDG PET/CT at baseline (PET-0), after induction (PET-AI) and at the end of treatment (PET-EoT) were enrolled. The patients had been prospectively enrolled in EMN02 and their PET scans were a posteriori reinterpreted in a blinded independent central review process managed by WIDEN registered. Five expert nuclear medicine physicians scored the scans according to the new criteria. A case was considered read when four out of the five reviewers completed the report. Concordance among reviewers on different metrics was calculated using Krippendorff's alpha coefficient. A total of 17 consecutive patients were enrolled. On PET-0, the alpha coefficients for the BM score, the score for the hottest focal lesion, the number of focal lesions and the number of lytic lesions were 0.33 and 0.47, 0.40 and 0.32, respectively. On PET-AI, the alpha coefficients

  2. Image interpretation criteria for FDG PET/CT in multiple myeloma: a new proposal from an Italian expert panel. IMPeTUs (Italian Myeloma criteria for PET USe)

    International Nuclear Information System (INIS)

    Nanni, Cristina; Rambaldi, Ilaria; Fanti, Stefano; Zamagni, Elena; Cavo, Michele; Versari, Annibale; Chauvie, Stephane; Bianchi, Andrea; Rensi, Marco; Bello, Marilena; Gallamini, Andrea; Patriarca, Francesca; Gay, Francesca; Gamberi, Barbara

    2016-01-01

    FDG PET/CT is able to detect active disease in patients with multiple myeloma (MM) and can be helpful for staging and assessing therapy response, but no standard interpretation criteria have been proposed for the evaluation of FDG PET/CT in MM. A group of Italian nuclear medicine physicians and haematologists met to propose new visual interpretation criteria to standardize FDG PET/CT evaluation in MM patients (Italian Myeloma criteria for PET USe; IMPeTUs) and the reproducibility of these criteria was tested. This Italian multicentre protocol was set up as a subprotocol of EMN02, an international prospective multicentre trial of the European Myeloma Network. The criteria were agreed at multidisciplinary consensus meetings. They include a description of the metabolic state of the bone marrow (BM), number and site of focal PET-positive lesions, the number of osteolytic lesions, and the presence and site of extramedullary disease, paramedullary disease and fractures. A visual degree of uptake was defined for the target lesion and extramedullary lesions according to modified Deauville criteria. MM patients who had undergone FDG PET/CT at baseline (PET-0), after induction (PET-AI) and at the end of treatment (PET-EoT) were enrolled. The patients had been prospectively enrolled in EMN02 and their PET scans were a posteriori reinterpreted in a blinded independent central review process managed by WIDEN registered. Five expert nuclear medicine physicians scored the scans according to the new criteria. A case was considered read when four out of the five reviewers completed the report. Concordance among reviewers on different metrics was calculated using Krippendorff's alpha coefficient. A total of 17 consecutive patients were enrolled. On PET-0, the alpha coefficients for the BM score, the score for the hottest focal lesion, the number of focal lesions and the number of lytic lesions were 0.33 and 0.47, 0.40 and 0.32, respectively. On PET-AI, the alpha coefficients

  3. Do carotid MR surface coils affect PET quantification in PET/MR imaging?

    International Nuclear Information System (INIS)

    Willemink, Martin J; Eldib, Mootaz; Leiner, Tim; Fayad, Zahi A; Mani, Venkatesh

    2015-01-01

    To evaluate the effect of surface coils for carotid MR imaging on PET quantification in a clinical simultaneous whole-body PET/MR scanner. A cylindrical phantom was filled with a homogeneous 2L water-FDG mixture at a starting dose of 301.2MBq. Clinical PET/MR and PET/CT systems were used to acquire PET-data without a coil (reference standard) and with two carotid MRI coils (Siemens Special Purpose 8-Channel and Machnet 4-Channel Phased Array). PET-signal attenuation was evaluated with Osirix using 51 (PET/MR) and 37 (PET/CT) circular ROIs. Mean and maximum standardized uptake values (SUVs) were quantified for each ROI. Furthermore, SUVs of PET/MR and PET/CT were compared. For validation, a patient was scanned with an injected dose of 407.7MBq on both a PET/CT and a PET/MR system without a coil and with both coils. PET/MR underestimations were -2.2% (Siemens) and -7.8% (Machnet) for SUVmean, and -1.2% (Siemens) and -3.3% (Machnet) for SUVmax, respectively. For PET/CT, underestimations were -1.3% (Siemens) and -1.4% (Machnet) for SUVmean and -0.5% (both Siemens and Machnet) for SUVmax, respectively using no coil data as reference. Except for PET/CT SUVmax values all differences were significant. SUVs differed significantly between PET/MR and PET/CT with SUVmean values of 0.51-0.55 for PET/MR and 0.68-0.69 for PET/CT, respectively. The patient examination showed that median SUVmean values measured in the carotid arteries decreased from 0.97 without a coil to 0.96 (Siemens) and 0.88 (Machnet). Carotid surface coils do affect attenuation correction in both PET/MR and PET/CT imaging. Furthermore, SUVs differed significantly between PET/MR and PET/CT.

  4. Preparation of reflective CsI photocathodes with reproducible high quantum efficiency

    Science.gov (United States)

    Maier-Komor, P.; Bauer, B. B.; Friese, J.; Gernhäuser, R.; Kienle, P.; Körner, H. J.; Montermann, G.; Zeitelhack, K.

    1995-02-01

    CsI as a solid UV-photocathode material has many promising applications in fast gaseous photon detectors. They are proposed in large area Ring Imaging CHerenkov (RICH) devices in forthcoming experiments at various high-energy particle accelerators. A high photon-to-electron conversion efficiency is a basic requirement for the successful operation of these devices. High reproducible quantum efficiencies could be achieved with CsI layers prepared by electron beam evaporation from a water-cooled copper crucible. CsI films were deposited in the thickness range of 30 to 500 μg/cm 2. Absorption coefficients and quantum efficiencies were measured in the wavelength region of 150 nm to 250 nm. The influence of various evaporation parameters on the quantum efficiency were investigated.

  5. Preparation of reflective CsI photocathodes with reproducible high quantum efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Maier-Komor, P. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Bauer, B.B. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Friese, J. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Gernhaeuser, R. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Kienle, P. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Koerner, H.J. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Montermann, G. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Zeitelhack, K. [Technische Univ. Muenchen, Garching (Germany). Physik-Department

    1995-08-01

    CsI as a solid UV-photocathode material has many promising applications in fast gaseous photon detectors. They are proposed in large area Ring Imaging CHerenkov (RICH) devices in forthcoming experiments at various high-energy particle accelerators. A high photon-to-electron conversion efficiency is a basic requirement for the successful operation of these devices. High reproducible quantum efficiencies could be achieved with CsI layers prepared by electron beam evaporation from a water-cooled copper crucible. CsI films were deposited in the thickness range of 30 to 500 {mu}g/cm{sup 2}. Absorption coefficients and quantum efficiencies were measured in the wavelength region of 150 nm to 250 nm. The influence of various evaporation parameters on the quantum efficiency were investigated. (orig.).

  6. Induced radioactivity of a GSO scintillator by secondary fragments in carbon ion therapy and its effects on in-beam OpenPET imaging.

    Science.gov (United States)

    Hirano, Yoshiyuki; Nitta, Munetaka; Nishikido, Fumihiko; Yoshida, Eiji; Inadama, Naoko; Yamaya, Taiga

    2016-07-07

    The accumulation of induced radioactivity within in-beam PET scanner scintillators is of concern for its long-term clinical usage in particle therapy. To estimate the effects on OpenPET which we are developing for in-beam PET based on GSOZ (Zi doped Gd2SiO5), we measured the induced radioactivity of GSO activated by secondary fragments in a water phantom irradiation by a (12)C beam with an energy of 290 MeV u(-1). Radioisotopes of Na, Ce, Eu, Gd, Nd, Pm and Tb including positron emitters were observed in the gamma ray spectra of the activated GSO with a high purity Ge detector and their absolute radioactivities were calculated. We used the Monte Carlo simulation platform, Geant4 in which the observed radioactivity was assigned to the scintillators of a precisely reproduced OpenPET and the single and coincidence rates immediately after one treatment and after one-year usage were estimated for the most severe conditions. Comparing the highest coincidence rate originating from the activated scintillators (background) and the expected coincidence rate from an imaging object (signal), we determined the expected signal-to-noise ratio to be more than 7 within 3 min and more than 10 within 1 min from the scan start time. We concluded the effects of scintillator activation and their accumulation on the OpenPET imaging were small and clinical long-term usage of the OpenPET was feasible.

  7. Advances in prostate-specific membrane antigen PET of prostate cancer.

    Science.gov (United States)

    Bouchelouche, Kirsten; Choyke, Peter L

    2018-05-01

    In recent years, a large number of reports have been published on prostate-specific membrane antigen (PSMA)/PET in prostate cancer (PCa). This review highlights advances in PSMA PET in PCa during the past year. PSMA PET/computed tomography (CT) is useful in detection of biochemical recurrence, especially at low prostate-specific antigen (PSA) values. The detection rate of PSMA PET is influenced by PSA level. For primary PCa, PSMA PET/CT shows promise for tumour localization in the prostate, especially in combination with multiparametric MRI (mpMRI). For primary staging, PSMA PET/CT can be used in intermediate and high-risk PCa. Intraoperative PSMA radioligand guidance seems promising for detection of malignant lymph nodes. While the use of PSMA PET/MRI in primary localized disease is limited to high and intermediate-risk patients and localized staging, in the recurrence setting, PET/MRI can be particularly helpful when the lesions are subtle. PSMA PET/CT is superior to choline PET/CT and other conventional imaging modalities. Molecular imaging with PSMA PET continues to pave the way for personalized medicine in PCa.However, large prospective clinical studies are still needed to fully evaluate the role of PSMA PET/CT and PET/MRI in the clinical workflow of PCa.

  8. Novel Geometrical Concept of a High Performance Brain PET Scanner Principle, Design and Performance Estimates

    CERN Document Server

    Séguinot, Jacques; Chesi, Enrico Guido; Joram, C; Mathot, S; Weilhammer, P; Chamizo-Llatas, M; Correia, J G; Ribeiro da Silva, M; Garibaldi, F; De Leo, R; Nappi, E; Corsi, F; Dragone, A; Schoenahl, F; Zaidi, H

    2006-01-01

    We present the principle, a possible implementation and performance estimates of a novel geometrical concept for a high resolution positron emission tomograph. The concept, which can for example be implemented in a brain PET device, promisses to lead to an essentially parallax free 3D image reconstruction with excellent spatial resolution and constrast, uniform over the complete field of view. The key components are matrices of long axially oriented scintillator crystals which are read out at both extremities by segmented Hybrid Photon Detectors. We discuss the relevant design considerations for a 3D axial PET camera module, motivate parameter and material choices, and estimate its performance in terms of spatial and energy resolution. We support these estimates by Monte Carlo simulations and in some cases by first experimental results. From the performance of a camera module, we extrapolate to the reconstruction resolution of a 3D axial PET scanner in a semi-analytical way and compare it to an existing state...

  9. Evaluation of PET performance and MR compatibility of a preclinical PET/MR insert with digital silicon photomultiplier technology

    Energy Technology Data Exchange (ETDEWEB)

    Hallen, Patrick; Schug, David; Wehner, Jakob [Department of Physics of Molecular Imaging Systems, RWTH Aachen University (Germany); Weissler, Bjorn [Department of Chemical Application Research, Philips Research (Germany); Gebhardt, Pierre [Division of Imaging Sciences and Biomedical Engineering, King’s College London (United Kingdom); Goldschmidt, Benjamin [Department of Physics of Molecular Imaging Systems, RWTH Aachen University (Germany); Salomon, Andre [Department of Oncology Solutions, Philips Research (Germany); Duppenbecker, Peter [Department of Physics of Molecular Imaging Systems, RWTH Aachen University (Germany); Kiessling, Fabian [Institute for Experimental Molecular Imaging, RWTH Aachen University (Germany); Schultz, Volkmar [Department of Physics of Molecular Imaging Systems, RWTH Aachen University (Germany)

    2015-05-18

    In this work we present detailed characterizations of our preclinical high resolution PET/MR insert based on the Hyperion-IID platform. The PET/MR insert consists of a ring of 10 singles detection modules, each comprising 2x3 scintillation detector stacks. Each detector stack features a 30x30 pixelated LYSO crystal array with a height of 12 mm and a pitch of 1 mm, coupled via a slit 2 mm light guide to a digital SiPM tile. The PET performance is stable under a wide range of operating points. The spatial resolution is below 1Ä,mm and the CRT reaches 260 or 450 ps depending on trigger settings. The energy resolution is 12.6% FWHM. The characterization of the MR compatibility showed no relevant degradation in PET performance during MRI operation. On the MRI side, we observe a degradation in B0 homogeneity from a VRMS of 0.03 ppm to 0.08 ppm with active shimming, while observing only minor degradations in the B0 field. The noise floor is slightly increased by 2-15% without any observable dependence on the activity. The Z gradients induces an observable eddy current inside the PET inserts which can lead to ghosting artifacts for EPI sequences. However, we don't observe any visible image degradation for widely used anatomical imaging sequences such as gradient echo and turbo spin echo sequences. To prove the viability of our PET/MR insert for in vivo small animal studies, we successfully performed a longitudinal mouse study with subcutaneously injected tumor model cells. The simultaneously acquired PET/MR images provide a high level of anatomical information and soft tissue contrast in the MR layer together with a high resolution image of the FDG tracer distribution in the PET layer.

  10. Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors

    International Nuclear Information System (INIS)

    Judenhofer, Martin S; Pichler, Bernd J; Cherry, Simon R

    2005-01-01

    Detectors used for positron emission tomography (PET) provide fast, randomly distributed signals that need to be digitized for further processing. One possibility is to sample the signals at the peak initiated by a trigger from a constant fraction discriminator (CFD). For PET detectors, simultaneous acquisition of many channels is often important. To develop and evaluate novel PET detectors, a flexible, relatively low cost and high performance laboratory data acquisition (DAQ) system is therefore required. The use of dedicated DAQ systems, such as a multi-channel analysers (MCAs) or continuous sampling boards at high rates, is expensive. This work evaluates the suitability of well-priced peripheral component interconnect (PCI)-based 8-channel DAQ boards (PD2-MFS-8 2M/14 and PD2-MFS-8-500k/14, United Electronic Industries Inc., Canton, MA, USA) for signal acquisition from novel PET detectors. A software package was developed to access the board, measure basic board parameters, and to acquire, visualize, and analyse energy spectra and position profiles from block detectors. The performance tests showed that the boards input linearity is >99.2% and the standard deviation is 22 Na source was 14.9% (FWHM) at 511 keV and is slightly better than the result obtained with a high-end single channel MCA (8000A, Amptek, USA) using the same detector (16.8%). The crystals (1.2 x 1.2 x 12 mm 3 ) within a 9 x 9 LSO block detector could be clearly separated in an acquired position profile. Thus, these boards are well suited for data acquisition with novel detectors developed for nuclear imaging

  11. An ASIC implementation of digital front-end electronics for a high resolution PET scanner

    International Nuclear Information System (INIS)

    Newport, D.F.; Young, J.W.

    1993-01-01

    AN Application Specific Integrated Circuit (ASIC) has been designed and fabricated which implements many of the current functions found in the digital front-end electronics for a high resolution Positron Emission Tomography (PET) scanner. The ASIC performs crystal selection, energy qualification, time correction, and event counting functions for block technology high resolution PET scanners. Digitized x and y position, event energy, and time information are used by the ASIC to determine block crystal number, qualify the event based on energy, and correct the event time. In addition, event counting and block dead time calculations are performed for system dead time corrections. A loadable sequencer for controlling the analog front-end electronics is also implemented. The ASIC is implemented in a 37,000 gate, 1.0 micron CMOS gate-array and is capable of handling 4 million events/second while reducing parts count, cost, and power consumption over current board-level designs

  12. [Principles of PET].

    Science.gov (United States)

    Beuthien-Baumann, B

    2018-05-01

    Positron emission tomography (PET) is a procedure in nuclear medicine, which is applied predominantly in oncological diagnostics. In the form of modern hybrid machines, such as PET computed tomography (PET/CT) and PET magnetic resonance imaging (PET/MRI) it has found wide acceptance and availability. The PET procedure is more than just another imaging technique, but a functional method with the capability for quantification in addition to the distribution pattern of the radiopharmaceutical, the results of which are used for therapeutic decisions. A profound knowledge of the principles of PET including the correct indications, patient preparation, and possible artifacts is mandatory for the correct interpretation of PET results.

  13. Additive value of amyloid-PET in routine cases of clinical dementia work-up after FDG-PET

    International Nuclear Information System (INIS)

    Brendel, Matthias; Schnabel, Jonas; Wagner, Leonie; Brendel, Eva; Meyer-Wilmes, Johanna; Unterrainer, Marcus; Schoenecker, Sonja; Prix, Catharina; Ackl, Nibal; Schildan, Andreas; Patt, Marianne; Barthel, Henryk; Sabri, Osama; Catak, Cihan; Pogarell, Oliver; Levin, Johannes; Danek, Adrian; Buerger, Katharina; Bartenstein, Peter; Rominger, Axel

    2017-01-01

    In recent years, several [ 18 F]-labeled amyloid-PET tracers have been developed and have obtained clinical approval. Despite their widespread scientific use, studies in routine clinical settings are limited. We therefore investigated the impact of [ 18 F]-florbetaben (FBB)-PET on the diagnostic management of patients with suspected dementia that was still unclarified after [ 18 F]-fluordeoxyglucose (FDG)-PET. All subjects were referred in-house with a suspected dementia syndrome due to neurodegenerative disease. After undergoing an FDG-PET exam, the cases were discussed by the interdisciplinary dementia board, where the most likely diagnosis as well as potential differential diagnoses were documented. Because of persistent diagnostic uncertainty, the patients received an additional FBB-PET exam. Results were interpreted visually and classified as amyloid-positive or amyloid-negative, and we then compared the individual clinical diagnoses before and after additional FBB-PET. A total of 107 patients (mean age 69.4 ± 9.7y) were included in the study. The FBB-PET was rated as amyloid-positive in 65/107. In 83% of the formerly unclear cases, a final diagnosis was reached through FBB-PET, and the most likely prior diagnosis was changed in 28% of cases. The highest impact was observed for distinguishing Alzheimer's dementia (AD) from fronto-temporal dementia (FTLD), where FBB-PET altered the most likely diagnosis in 41% of cases. FBB-PET has a high additive value in establishing a final diagnosis in suspected dementia cases when prior investigations such as FDG-PET are inconclusive. The differentiation between AD and FTLD was particularly facilitated by amyloid-PET, predicting a considerable impact on patient management, especially in the light of upcoming disease-modifying therapies. (orig.)

  14. Additive value of amyloid-PET in routine cases of clinical dementia work-up after FDG-PET

    Energy Technology Data Exchange (ETDEWEB)

    Brendel, Matthias; Schnabel, Jonas; Wagner, Leonie; Brendel, Eva; Meyer-Wilmes, Johanna; Unterrainer, Marcus [University Hospital, LMU Munich, Department of Nuclear Medicine, Munich (Germany); Schoenecker, Sonja; Prix, Catharina; Ackl, Nibal [University Hospital, LMU Munich, Department of Neurology, Munich (Germany); Schildan, Andreas; Patt, Marianne; Barthel, Henryk; Sabri, Osama [University of Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Catak, Cihan [Klinikum der Universitaet Muenchen, Institute for Stroke and Dementia Research, Munich (Germany); Pogarell, Oliver [University Hospital, LMU Munich, Department of Psychiatry, Munich (Germany); Levin, Johannes; Danek, Adrian [University Hospital, LMU Munich, Department of Neurology, Munich (Germany); DZNE - German Center for Neurodegenerative Diseases, Munich (Germany); Buerger, Katharina [Klinikum der Universitaet Muenchen, Institute for Stroke and Dementia Research, Munich (Germany); DZNE - German Center for Neurodegenerative Diseases, Munich (Germany); Bartenstein, Peter; Rominger, Axel [University Hospital, LMU Munich, Department of Nuclear Medicine, Munich (Germany); Munich Cluster for Systems Neurology (SyNergy), Munich (Germany)

    2017-12-15

    In recent years, several [{sup 18}F]-labeled amyloid-PET tracers have been developed and have obtained clinical approval. Despite their widespread scientific use, studies in routine clinical settings are limited. We therefore investigated the impact of [{sup 18}F]-florbetaben (FBB)-PET on the diagnostic management of patients with suspected dementia that was still unclarified after [{sup 18}F]-fluordeoxyglucose (FDG)-PET. All subjects were referred in-house with a suspected dementia syndrome due to neurodegenerative disease. After undergoing an FDG-PET exam, the cases were discussed by the interdisciplinary dementia board, where the most likely diagnosis as well as potential differential diagnoses were documented. Because of persistent diagnostic uncertainty, the patients received an additional FBB-PET exam. Results were interpreted visually and classified as amyloid-positive or amyloid-negative, and we then compared the individual clinical diagnoses before and after additional FBB-PET. A total of 107 patients (mean age 69.4 ± 9.7y) were included in the study. The FBB-PET was rated as amyloid-positive in 65/107. In 83% of the formerly unclear cases, a final diagnosis was reached through FBB-PET, and the most likely prior diagnosis was changed in 28% of cases. The highest impact was observed for distinguishing Alzheimer's dementia (AD) from fronto-temporal dementia (FTLD), where FBB-PET altered the most likely diagnosis in 41% of cases. FBB-PET has a high additive value in establishing a final diagnosis in suspected dementia cases when prior investigations such as FDG-PET are inconclusive. The differentiation between AD and FTLD was particularly facilitated by amyloid-PET, predicting a considerable impact on patient management, especially in the light of upcoming disease-modifying therapies. (orig.)

  15. Diagnostic accuracy of (18F-FDG PET/CT for the detection of peritoneal carcinomatosis of colorectal origins

    Directory of Open Access Journals (Sweden)

    Bullier E

    2013-03-01

    Full Text Available Purpose: to evaluate the diagnostic accuracy of (18 F-FDG positron emission tomography/ computerized tomography (PET/CT for the detection of peritoneal carcinomatosis (PC of colorectal cancer (CRC. Methods: one hundred and forty six eligible patients referred for a PET/CT to evaluate CRC at a single institution were included consecutively and retrospectively. After joint training on 20 similar patient files, two nuclear physicians reviewed the PET/CT scans blindly and independently using a method specifically designed for PC detection. The gold standard was either histological results from surgical exploration for resected patients (n=65 or clinical follow up defined as the 3-month CT follow up supplemented by one year of clinical information and CT monitoring for non-resected patients (n=81. As secondary objectives we evaluated the interobserver reliability between the two PET/CT readings and the diagnostic accuracy of a contemporary ceCT (n=69 or CT component of the PET/CT (n=77 reviewed by an independent radiologist . The extent of PC according to a simplified Sugarbaker index (PCI was examined for the operated subgroup, when PCI was available from the surgeon and PET/CT (n=12. Results: according to the gold standard, 35/146 patients had PC (including 19 of 65 patients with histological gold standard and 16 of 81 patients with clinical follow up gold standard. Sensitivity and specificity of PET/CT were 88% and 96% respectively and positive and negative predictive values and accuracy, 88%, 96% and 94% respectively. For CT alone, the corresponding values were: 68%, 92%, 72%, 90% and 86%. The interobserver agreement for the detection of peritoneal carcinomatosis in PET/CT showed high agreement at 0.91 (Kappa. Median PCI was 3 [range: 1–13] when assessed by surgeons and 4 [range: 1–10] on PET/CT. Focal uptake was the most frequently observed sign on PET. Conclusions: PET/CT appears to be an accurate and reproducible test for PC diagnosis in

  16. MR-assisted PET motion correction in simultaneous PET/MRI studies of dementia subjects.

    Science.gov (United States)

    Chen, Kevin T; Salcedo, Stephanie; Chonde, Daniel B; Izquierdo-Garcia, David; Levine, Michael A; Price, Julie C; Dickerson, Bradford C; Catana, Ciprian

    2018-03-08

    Subject motion in positron emission tomography (PET) studies leads to image blurring and artifacts; simultaneously acquired magnetic resonance imaging (MRI) data provides a means for motion correction (MC) in integrated PET/MRI scanners. To assess the effect of realistic head motion and MR-based MC on static [ 18 F]-fluorodeoxyglucose (FDG) PET images in dementia patients. Observational study. Thirty dementia subjects were recruited. 3T hybrid PET/MR scanner where EPI-based and T 1 -weighted sequences were acquired simultaneously with the PET data. Head motion parameters estimated from high temporal resolution MR volumes were used for PET MC. The MR-based MC method was compared to PET frame-based MC methods in which motion parameters were estimated by coregistering 5-minute frames before and after accounting for the attenuation-emission mismatch. The relative changes in standardized uptake value ratios (SUVRs) between the PET volumes processed with the various MC methods, without MC, and the PET volumes with simulated motion were compared in relevant brain regions. The absolute value of the regional SUVR relative change was assessed with pairwise paired t-tests testing at the P = 0.05 level, comparing the values obtained through different MR-based MC processing methods as well as across different motion groups. The intraregion voxelwise variability of regional SUVRs obtained through different MR-based MC processing methods was also assessed with pairwise paired t-tests testing at the P = 0.05 level. MC had a greater impact on PET data quantification in subjects with larger amplitude motion (higher than 18% in the medial orbitofrontal cortex) and greater changes were generally observed for the MR-based MC method compared to the frame-based methods. Furthermore, a mean relative change of ∼4% was observed after MC even at the group level, suggesting the importance of routinely applying this correction. The intraregion voxelwise variability of regional SUVRs

  17. The usefulness of integrated PET/CT simulator for non-small cell lung cancer using the F-18 fluoro-2-deoxyglucose (FDG)

    Energy Technology Data Exchange (ETDEWEB)

    Na, Jong Eok; Suh, Jeong Nam; Kim, Jin Soo; Kim, Dae Seob; Hong, Dong Ki; Baek, Geum Mun [Dept. of Radiation Oncology, Asan Medical Center, Seoul (Korea, Republic of)

    2013-03-15

    To evaluate the usefulness of Integrated PET/CT and compare the gloss tumor volume (GTV) identified on CT, PET, PET/CT to that obtained from fluorodeoxyglucose (FDG). This experimental study was obtained using GE Discovery 690 (General Electric Healthcare, Milwaukee, MI, USA) PET/CT simulator with Gammex Laser System for five non-small cell lung cancer (NSCLC) patients. In order to increase the reproducibility of the patient setup, We have to fixed to patients using the Extended Wing Board. GTV delineation was painted using the EclipseTM ver.10 contouring program for CT, PET, PET/CT images. And then, We were to compare the changes in the GTV. These results are drawn from 5 patients who have atelectasis or pneumonitis. Compared to CT defined GTV, PET was decreased by 10.5%, 11.8% and increased by 67.9%, 220%, 19.4%. PET/CT was decreased by 7.7%, 6.7%, 28% and increased by 232%, 24%. We were able to determine the usefulness of PET/CT simulator for NSCLC. PET/CT simulator in radiation therapy is useful to define the target volume and It is possible to delineate Objective and accurate target volume. It seems to be applicable to other areas in the near future.

  18. Textural analysis of pre-therapeutic [18F]-FET-PET and its correlation with tumor grade and patient survival in high-grade gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Pyka, Thomas; Hiob, Daniela; Wester, Hans-Juergen [Klinikum Rechts der Isar der TU Muenchen, Department of Nuclear Medicine, Munich (Germany); Gempt, Jens; Ringel, Florian; Meyer, Bernhard [Klinikum Rechts der Isar der TU Muenchen, Neurosurgic Department, Munich (Germany); Schlegel, Juergen [Klinikum Rechts der Isar der TU Muenchen, Institute of Pathology and Neuropathology, Munich (Germany); Bette, Stefanie [Klinikum Rechts der Isar der TU Muenchen, Neuroradiologic department, Munich (Germany); Foerster, Stefan [Klinikum Rechts der Isar der TU Muenchen, Department of Nuclear Medicine, Munich (Germany); Klinikum Rechts der Isar der TU Muenchen, TUM Neuroimaging Center (TUM-NIC), Munich (Germany)

    2016-01-15

    Amino acid positron emission tomography (PET) with [18F]-fluoroethyl-L-tyrosine (FET) is well established in the diagnostic work-up of malignant brain tumors. Analysis of FET-PET data using tumor-to-background ratios (TBR) has been shown to be highly valuable for the detection of viable hypermetabolic brain tumor tissue; however, it has not proven equally useful for tumor grading. Recently, textural features in 18-fluorodeoxyglucose-PET have been proposed as a method to quantify the heterogeneity of glucose metabolism in a variety of tumor entities. Herein we evaluate whether textural FET-PET features are of utility for grading and prognostication in patients with high-grade gliomas. One hundred thirteen patients (70 men, 43 women) with histologically proven high-grade gliomas were included in this retrospective study. All patients received static FET-PET scans prior to first-line therapy. TBR (max and mean), volumetric parameters and textural parameters based on gray-level neighborhood difference matrices were derived from static FET-PET images. Receiver operating characteristic (ROC) and discriminant function analyses were used to assess the value for tumor grading. Kaplan-Meier curves and univariate and multivariate Cox regression were employed for analysis of progression-free and overall survival. All FET-PET textural parameters showed the ability to differentiate between World Health Organization (WHO) grade III and IV tumors (p < 0.001; AUC 0.775). Further improvement in discriminatory power was possible through a combination of texture and metabolic tumor volume, classifying 85 % of tumors correctly (AUC 0.830). TBR and volumetric parameters alone were correlated with tumor grade, but showed lower AUC values (0.644 and 0.710, respectively). Furthermore, a correlation of FET-PET texture but not TBR was shown with patient PFS and OS, proving significant in multivariate analysis as well. Volumetric parameters were predictive for OS, but this correlation did not

  19. FDG-PET in Follicular Lymphoma Management

    Directory of Open Access Journals (Sweden)

    C. Bodet-Milin

    2012-01-01

    Full Text Available 18-Fluoro-deoxyglucose positron emission tomography/computerised tomography (FDG PET/CT is commonly used in the management of patients with lymphomas and is recommended for both initial staging and response assessment after treatment in patients with diffuse large B-cell lymphoma and Hodgkin lymphoma. Despite the FDG avidity of follicular lymphoma (FL, FDG PET/CT is not yet applied in standard clinical practice for patients with FL. However, FDG PET/CT is more accurate than conventional imaging for initial staging, often prompting significant management change, and allows noninvasive characterization to guide assessment of high-grade transformation. For restaging, FDG PET/CT assists in distinguishing between scar tissue and viable tumors in residual masses and a positive PET after induction treatment would seem to predict a shorter progression-free survival.

  20. International Interlaboratory Digital PCR Study Demonstrating High Reproducibility for the Measurement of a Rare Sequence Variant.

    Science.gov (United States)

    Whale, Alexandra S; Devonshire, Alison S; Karlin-Neumann, George; Regan, Jack; Javier, Leanne; Cowen, Simon; Fernandez-Gonzalez, Ana; Jones, Gerwyn M; Redshaw, Nicholas; Beck, Julia; Berger, Andreas W; Combaret, Valérie; Dahl Kjersgaard, Nina; Davis, Lisa; Fina, Frederic; Forshew, Tim; Fredslund Andersen, Rikke; Galbiati, Silvia; González Hernández, Álvaro; Haynes, Charles A; Janku, Filip; Lacave, Roger; Lee, Justin; Mistry, Vilas; Pender, Alexandra; Pradines, Anne; Proudhon, Charlotte; Saal, Lao H; Stieglitz, Elliot; Ulrich, Bryan; Foy, Carole A; Parkes, Helen; Tzonev, Svilen; Huggett, Jim F

    2017-02-07

    This study tested the claim that digital PCR (dPCR) can offer highly reproducible quantitative measurements in disparate laboratories. Twenty-one laboratories measured four blinded samples containing different quantities of a KRAS fragment encoding G12D, an important genetic marker for guiding therapy of certain cancers. This marker is challenging to quantify reproducibly using quantitative PCR (qPCR) or next generation sequencing (NGS) due to the presence of competing wild type sequences and the need for calibration. Using dPCR, 18 laboratories were able to quantify the G12D marker within 12% of each other in all samples. Three laboratories appeared to measure consistently outlying results; however, proper application of a follow-up analysis recommendation rectified their data. Our findings show that dPCR has demonstrable reproducibility across a large number of laboratories without calibration. This could enable the reproducible application of molecular stratification to guide therapy and, potentially, for molecular diagnostics.

  1. A Movable Phantom Design for Quantitative Evaluation of Motion Correction Studies on High Resolution PET Scanners

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Svarer, C.; Sibomana, M.

    2010-01-01

    maximization algorithm with modeling of the point spread function (3DOSEM-PSF), and they were corrected for motions based on external tracking information using the Polaris Vicra real-time stereo motion-tracking system. The new automatic, movable phantom has a robust design and is a potential quality......Head movements during brain imaging using high resolution positron emission tomography (PET) impair the image quality which, along with the improvement of the spatial resolution of PET scanners, in general, raises the importance of motion correction. Here, we present a new design for an automatic...

  2. Relevance of positron emission tomography (PET) in oncology

    International Nuclear Information System (INIS)

    Weber, W.A.; Avril, N.; Schwaiger, M.

    1999-01-01

    Background: The clinical use of positron emission tomography (PET) for detection and staging of malignant tumors is rapidly increasing. Furthermore, encouraging results for monitoring the effects of radio- and chemotherapy have been reported. Methods: This review describes the technical principles of PET and the biological characteristics of tracers used in oncological research and patient studies. The results of clinical studies published in peer reviewed journals during the last 5 years are summarized and clinical indications for PET scans in various tumor types are discussed. Results and Conclusions: Numerous studies have documented the high diagnostic accuracy of PET studies using the glucose analogue F-18-fluordeoxyglucose (FDG-PET) for detection and staging of malignant tumors. In this field, FDG-PET has been particularly successful in lung cancer, colorectal cancer, malignant lymphoma and melanoma. Furthermore, FDG-PET has often proven to be superior to morphological imaging techniques for differentation of tumor recurrence from scar tissue. Due to the high glucose utilization of normal gray matter radiolabeled amino-acids like C-11-methionine are superior to FDG for detection and delineation of brain tumors by PET. In the future, more specific markers of tumor cell proliferation and gene expression may allow the application of PET not only for dianostic imaging also but for non-invasive biological characterization of malignant tumors and early monitoring of therapeutic interventions. (orig.) [de

  3. Molecular imaging of neuroendocrine tumors using {sup 68}Ga-labeled peptides (Somatostatin receptor PET/CT); Molekulare Bildgebung neuroendokriner Tumoren mit {sup 68}Ga-markierten Peptiden (Somatostatinrezeptor-PET/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Baum, R.P.; Prasad, V. [Zentralklinik Bad Berka GmbH (Germany). Klinik fuer Nuklearmedizin/PET-Zentrum; Hoersch, D. [Zentralklinik Bad Berka GmbH (Germany). Klinik fuer Innere Medizin, Gastroenterologie, Onkologie, Endokrionologie

    2009-06-15

    Receptor PET/CT using {sup 68}Ga-labeled somatostatin analogues (DOTA-NOC, DOTA-TOC or DOTA-TATE) enables the highly sensitive molecular imaging of neuroendocrine tumors (NETs) based on the expression of somatostatin receptors and even the detection of receptor subtypes. Our experience after more than 3000 studies shows that receptor PET/CT has a significantly higher tumor detection rate than conventional scintigraphy (even in SPECT/CT technique), and that tumor lesions can be very accurately localized. By calculating standardized uptake values (SUV) - which are reproducible and investigator-independent - patients can be selected for peptide receptor radiotherapy and also the course after therapy can be controlled. Receptor-PET/CT is the most sensitive imaging modality for the detection of unknown primary tumors (CUP syndrome), which is especially true for the detection of neuroendocrine tumors of the pancreas and small bowel; whole-body staging (''one stop shop'') as well as restaging and selection of patients for peptide receptor radiotherapy can be performed using a patient-friendly procedure (examination finished within one hour) exposing the patient to less radiation than whole-body CT scanning. The {sup 68}Ge/{sup 68}Ga generator has proved very reliable over the years - even in a hospital environment. The effective costs for {sup 68}Ga labeled somatostatin analogues might be less than for scintigraphic agents, provided a certain number of studies per year are performed. The development of new tumor-specific peptides as well as of other DOTA- or NOTA-coupled radiopharmaceuticals opens a new avenue into the future: finally, the {sup 68}Ga generator could play a similar important role for PET/CT as did the {sup 99m}Tc-Generator for conventional gamma camera imaging over the last decades. (orig.)

  4. An experimental phantom study of the effect of gadolinium-based MR contrast agents on PET attenuation coefficients and PET quantification in PET-MR imaging: application to cardiac studies.

    Science.gov (United States)

    O' Doherty, Jim; Schleyer, Paul

    2017-12-01

    Simultaneous cardiac perfusion studies are an increasing trend in PET-MR imaging. During dynamic PET imaging, the introduction of gadolinium-based MR contrast agents (GBCA) at high concentrations during a dual injection of GBCA and PET radiotracer may cause increased attenuation effects of the PET signal, and thus errors in quantification of PET images. We thus aimed to calculate the change in linear attenuation coefficient (LAC) of a mixture of PET radiotracer and increasing concentrations of GBCA in solution and furthermore, to investigate if this change in LAC produced a measurable effect on the image-based PET activity concentration when attenuation corrected by three different AC strategies. We performed simultaneous PET-MR imaging of a phantom in a static scenario using a fixed activity of 40 MBq [18 F]-NaF, water, and an increasing GBCA concentration from 0 to 66 mM (based on an assumed maximum possible concentration of GBCA in the left ventricle in a clinical study). This simulated a range of clinical concentrations of GBCA. We investigated two methods to calculate the LAC of the solution mixture at 511 keV: (1) a mathematical mixture rule and (2) CT imaging of each concentration step and subsequent conversion to LAC at 511 keV. This comparison showed that the ranges of LAC produced by both methods are equivalent with an increase in LAC of the mixed solution of approximately 2% over the range of 0-66 mM. We then employed three different attenuation correction methods to the PET data: (1) each PET scan at a specific millimolar concentration of GBCA corrected by its corresponding CT scan, (2) each PET scan corrected by a CT scan with no GBCA present (i.e., at 0 mM GBCA), and (3) a manually generated attenuation map, whereby all CT voxels in the phantom at 0 mM were replaced by LAC = 0.1 cm -1 . All attenuation correction methods (1-3) were accurate to the true measured activity concentration within 5%, and there were no trends in image

  5. SiliPET: An ultra high resolution design of a small animal PET scanner based on double sided silicon strip detector stacks

    International Nuclear Information System (INIS)

    Zavattini, G.; Cesca, N.; Di Domenico, G.; Moretti, E.; Sabba, N.

    2006-01-01

    We investigated the capabilities of a small animal PET scanner, named SiliPET, based on four stacks of double sided silicon strips detectors. Each stack consists of 40 silicon detectors with dimension 60x60x1mm 3 . These are arranged to form a box 5x5x6cm 3 with minor sides opened; the box represents the maximal FOV of the scanner. The performance parameters of SiliPET scanner have been estimated, giving an intrinsic spatial resolution of 0.52mm and a sensitivity of 5.1% at the center of the system

  6. CNS metabolism in high-risk drug abuse, German version. Insights gained from "1H- and "3"1P MRS and PET

    International Nuclear Information System (INIS)

    Bodea, S.V.

    2017-01-01

    High-risk drug consumption is a considerable problem for public health actors in industrialised countries. The latest trends show a market tendency towards diversification and increasing demand for high-purity synthetic drugs. Whilst most consumers seek medical help after cannabis use, it is high-risk drugs like cocaine, heroin and amphetamines that account for most of the 1000 drug-related deaths that occur in Germany every year. This article presents the most prominent in vivo cerebral metabolic information in cocaine, heroin and methamphetamine users provided by MRI spectroscopy and PET imaging. We reviewed the literature reporting neuroimaging studies of in vivo metabolic data for methamphetamine, cocaine and heroin consumption published up to March 2017. The search was conducted using PubMed with the following key words: methamphetamine, cocaine, heroin, MR spectroscopy, PET. MRI and PET are indispensable tools in gauging brain metabolic response to illegal drug abuse. Future breakthroughs in this field will most likely come from the investigation of novel neurotransmitter systems in PET and imaging phosphorus and carbon metabolites in MRI. (orig.) [de

  7. Prediction of standard-dose brain PET image by using MRI and low-dose brain [{sup 18}F]FDG PET images

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jiayin [School of Electronics Engineering, Huaihai Institute of Technology, Lianyungang, Jiangsu 222005, China and IDEA Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Gao, Yaozong [IDEA Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 and Department of Computer Science, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Shi, Feng [IDEA Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Lalush, David S. [Joint UNC-NCSU Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States); Lin, Weili [MRI Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Shen, Dinggang, E-mail: dgshen@med.unc.edu [IDEA Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 and Department of Brain and Cognitive Engineering, Korea University, Seoul 136-713 (Korea, Republic of)

    2015-09-15

    Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain [{sup 18}F]FDG PET image by using a low-dose brain [{sup 18}F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain [{sup 18}F]FDG PET image by low-dose brain [{sup 18}F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain [{sup 18}F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain [{sup 18}F]FDG PET

  8. Prediction of standard-dose brain PET image by using MRI and low-dose brain ["1"8F]FDG PET images

    International Nuclear Information System (INIS)

    Kang, Jiayin; Gao, Yaozong; Shi, Feng; Lalush, David S.; Lin, Weili; Shen, Dinggang

    2015-01-01

    Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain ["1"8F]FDG PET image by using a low-dose brain ["1"8F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain ["1"8F]FDG PET image by low-dose brain ["1"8F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain ["1"8F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain ["1"8F]FDG PET image and substantially

  9. Lung PET scan

    Science.gov (United States)

    ... Chest PET scan; Lung positron emission tomography; PET - chest; PET - lung; PET - tumor imaging; ... Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging . 6th ed. Philadelphia, ...

  10. Low-count PET image restoration using sparse representation

    Science.gov (United States)

    Li, Tao; Jiang, Changhui; Gao, Juan; Yang, Yongfeng; Liang, Dong; Liu, Xin; Zheng, Hairong; Hu, Zhanli

    2018-04-01

    In the field of positron emission tomography (PET), reconstructed images are often blurry and contain noise. These problems are primarily caused by the low resolution of projection data. Solving this problem by improving hardware is an expensive solution, and therefore, we attempted to develop a solution based on optimizing several related algorithms in both the reconstruction and image post-processing domains. As sparse technology is widely used, sparse prediction is increasingly applied to solve this problem. In this paper, we propose a new sparse method to process low-resolution PET images. Two dictionaries (D1 for low-resolution PET images and D2 for high-resolution PET images) are learned from a group real PET image data sets. Among these two dictionaries, D1 is used to obtain a sparse representation for each patch of the input PET image. Then, a high-resolution PET image is generated from this sparse representation using D2. Experimental results indicate that the proposed method exhibits a stable and superior ability to enhance image resolution and recover image details. Quantitatively, this method achieves better performance than traditional methods. This proposed strategy is a new and efficient approach for improving the quality of PET images.

  11. Silver nanowires for highly reproducible cantilever based AFM-TERS microscopy: towards a universal TERS probe.

    Science.gov (United States)

    Walke, Peter; Fujita, Yasuhiko; Peeters, Wannes; Toyouchi, Shuichi; Frederickx, Wout; De Feyter, Steven; Uji-I, Hiroshi

    2018-04-26

    Tip-enhanced Raman scattering (TERS) microscopy is a unique analytical tool to provide complementary chemical and topographic information of surfaces with nanometric resolution. However, difficulties in reliably producing the necessary metallized scanning probe tips has limited its widespread utilisation, particularly in the case of cantilever-based atomic force microscopy. Attempts to alleviate tip related issues using colloidal or bottom-up engineered tips have so far not reported consistent probes for both Raman and topographic imaging. Here we demonstrate the reproducible fabrication of cantilever-based high-performance TERS probes for both topographic and Raman measurements, based on an approach that utilises noble metal nanowires as the active TERS probe. The tips show 10 times higher TERS contrasts than the most typically used electrochemically-etched tips, and show a reproducibility for TERS greater than 90%, far greater than found with standard methods. We show that TERS can be performed in tapping as well as contact AFM mode, with optical resolutions around or below 15 nm, and with a maximum resolution achieved in tapping-mode of 6 nm. Our work illustrates that superior TERS probes can be produced in a fast and cost-effective manner using simple wet-chemistry methods, leading to reliable and reproducible high-resolution and high-sensitivity TERS, and thus renders the technique applicable for a broad community.

  12. Progress on dedicated animal PET

    International Nuclear Information System (INIS)

    Liu Wei

    2002-01-01

    Positron emission tomography, as the leading technology providing molecular imaging of biological processes, is widely used on living laboratory animals. High-resolution dedicated animal PET scanners have been developed. Although the dedicated animal PET faces obstacles and challenges, this advanced technology would play an important role in molecular biomedicine researches, such as diseases study, medicine development, and gene therapy

  13. Impact of [F-18]-fluoro-ethyl-tyrosine PET imaging on target definition for radiation therapy of high-grade glioma

    DEFF Research Database (Denmark)

    af Rosenschold, Per Munck; Costa, Junia; Engelholm, Svend Aage

    2015-01-01

    BACKGROUND: We sought to assess the impact of amino-acid (18)F-fluoro-ethyl-tyrosine (FET) positron emission tomography (PET) on the volumetric target definition for radiation therapy of high-grade glioma versus the current standard using MRI alone. Specifically, we investigated the influence....... Patients with grade IV glioma were found to be the primary candidates for PET-guided radiation therapy planning....

  14. Simultaneous PET/MRI with 13C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification

    DEFF Research Database (Denmark)

    Hansen, Adam E.; Andersen, Flemming L.; Henriksen, Sarah T.

    2016-01-01

    Background: Integrated PET/MRI with hyperpolarized 13C magnetic resonance spectroscopic imaging (13C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented...... for a clinical whole-body system using simultaneous 1 H-MRI and PET but never for 13C-MRSI and PET. Here, the feasibility of simultaneous PET and 13C-MRSI as well as hyperpolarized 13C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. Methods: Combined PET and 13C......-MRSI phantoms including a NEMA [18F]-FDG phantom, 13C-acetate and 13C-urea sources, and hyperpolarized 13C-pyruvate were imaged repeatedly with PET and/or 13C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET...

  15. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs

  16. Positron Emission Tomography (PET)

    Science.gov (United States)

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  17. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  18. Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

    Science.gov (United States)

    Dang, Jun; Frisch, Benjamin; Lasaygues, Philippe; Zhang, Dachun; Tavernier, Stefaan; Felix, Nicolas; Lecoq, Paul; Auffray, Etiennette; Varela, Joao; Mensah, Serge; Wan, Mingxi

    2011-06-01

    Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allows labeling the different tissues in the phantom with different concentrations of FDG. The phantom was imaged with a whole-body PET/CT and with the Supersonic Imagine Aixplorer system. This system allows both B-mode US and shear wave elastographic imaging. US elastography is a new imaging method for displaying the tissue elasticity distribution. It was shown to be useful in breast imaging. We also tested the phantom with static elastography. A 6D magnetic positioning system allows fusing the images obtained with the two modalities. ClearPEM-Sonic is a project of the Crystal Clear Collaboration and the European Centre for Research on Medical Imaging (CERIMED).

  19. PET in management of breast cancer

    International Nuclear Information System (INIS)

    Lee, Myung-Chul

    2004-01-01

    Full text: PET provides useful information about tumor metabolism enabling accurate visualization of malignant lesions. Approximately 60-80% suspicious lesions on mammography have benign histology and about 10% of breast cancers with palpable mass are not identified in mammography. The key roles of PET technology in breast cancer are in: primary diagnosis, staging, recurrent diseases monitoring and prediction of therapy response. The sensitivity and specificity of FDG-PET for the diagnosis of breast cancer has been reported to be 68-100% and 83-100%, respectively. Considering the increasing number of small breast tumors detected by mammography and false negative results, the clinical relevance of FDG-PET for the primary diagnosis is limited. In selected patients, however, for example with dense breasts, breasts implants, augmented breast or after breast surgery, which can affect the accuracy of mammography, and in cases with equivocal mammography, FDG-PET can provide clinically relevant information. PET accurately determines the extent of disease, including the loco-regional lymph node status. Furthermore, whole-body PET imaging promises a high diagnostic accuracy for detecting recurrent or metastatic breast carcinoma with a high positive predictive value. We studied the usefulness of the FDG-PET in 42 preoperative patients with suspected breast cancer in differentiation of lesions. The diagnostic value of FDG-PET in terms of sensitivity and specificity was 95% and 77% respectively in primary mass while it was 73% and 100% for axillary lymph nodes. PET is much more accurate than other conventional modalities. The sensitivity of FDG-PET for correct staging of axillary nodal status is 84-100%. It has the potential to replace conventional procedures for the staging of distant metastases. We observed the sensitivity and the specificity of FDG-PET to be 96% and 85% to detect distant metastases. FDG-PET may become the method of choice for the early assessment of

  20. Comparison of volumetric and functional parameters in simultaneous cardiac PET/MR: feasibility of volumetric assessment with residual activity from prior PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Luecke, C.; Brenneis, B.; Grothoff, M.; Gutberlet, M. [University Leipzig - Heart Center, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Oppolzer, B.; Werner, P.; Jochimsen, T.; Sattler, B.; Barthel, H.; Sabri, O. [University Hospital Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Foldyna, B. [University Leipzig - Heart Center, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Massachusetts General Hospital - Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); Lurz, P. [University Leipzig - Heart Center, Clinic for Internal Medicine/Cardiology, Leipzig (Germany); Lehmkuhl, L. [Herz- und Gefaess-Klinik GmbH, Radiologische Klinik, Bad Neustadt (Germany)

    2017-12-15

    To compare cardiac left ventricular (LV) parameters in simultaneously acquired hybrid fluorine-18-fluorodeoxyglucose ([18F] FDG) positron emission tomography/magnetic resonance imaging (PET/MRI) in patients with residual tracer activity of upstream PET/CT. Twenty-nine patients (23 men, age 58±17 years) underwent cardiac PET/MRI either directly after a non-cardiac PET/CT with homogenous cardiac [18F] FDG uptake (n=20) or for viability assessment (n=9). Gated cardiac [18F] FDG PET and cine MR sequences were acquired simultaneously and evaluated blinded to the cross-imaging results. Image quality (IQ), end-diastolic (LVEDV), end-systolic volume (LVESV), ejection fraction (LVEF) and myocardial mass (LVMM) were measured. Pearson correlation and intraclass correlation coefficient (ICC), regression and a Bland-Altman analysis were assessed. Except LVMM, volumetric and functional LV parameters demonstrated high correlations (LVESV: r=0.97, LVEDV: r=0.95, LVEF: r=0.91, LVMM: r=0.87, each p<0.05), but wide limits of agreement (LOA) for LVEDV (-25.3-82.5ml); LVESV (-33.1-72.7ml); LVEF (-18.9-14.8%) and LVMM (-78.2-43.2g). Intra- and interobserver reliability were very high (ICC≥0.95) for all parameters, except for MR-LVEF (ICC=0.87). PET-IQ (0-3) was high (mean: 2.2±0.9) with significant influence on LVMM calculations only. In simultaneously acquired cardiac PET/MRI data, LVEDV, LVESV and LVEF show good agreement. However, the agreement seems to be limited if cardiac PET/MRI follows PET/CT and only the residual activity is used. (orig.)

  1. Oral cancer diagnosed using PET/CT: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hee; Yang, Byoung Eun; Cho, Young Min [Hallym Univ. College of Medicine, Anyang (Korea, Republic of); Kim, Seong Gon [Sam Anyang General Hospital, Anyang (Korea, Republic of)

    2006-06-15

    PET/CT is a new imaging technology that combines high-quality Position Emission Tomography (PET) and Computed Tomography (CT). This imaging provides simultaneous anatomical and metabolic information. Therefore PET/CT is useful diagnostic modality for early detection og malignant tumor, accurate at aging, decision on therapeutic plan, monitoring response to therapy and rapid detection of recurrence. We report oral and maxillofacial cancers diagnosed by using PET/CT and the usefulness of PET/CT in the evaluation of postoperative recurrence.

  2. PET and PET/CT in tumour of undetermined origin; PET y PET/CT en tumor de origen indeterminado

    Energy Technology Data Exchange (ETDEWEB)

    Garcia O, J R [Nuclear Medicine and Molecular Imaging, PET/CT, Centro Medico ABC, Mexico D.F. (Mexico)

    2007-07-01

    In this presentation the following conclusions were obtained regarding the use of PET and PET/CT in patient with cancer of unknown primary: 1. Detection of the primary one in 1/3 at 1/2 of patient. 2. It detects metastases in other places in 50%. 3. It changes the initial therapy planned in 1/3 at 1/2 of patient. 4. Useful in initial phases of protocol study to limit the other procedures. After standard evaluation. Before advanced protocol. 5. PET/CT study increases the % of primary detection, although in a non significant way vs. PET. 6. They are required more studies to value their utility to a more objective manner. (Author)

  3. Quantitative myocardial perfusion PET combined with coronary anatomy derived from CT angiography. Validation of a new fusion and visualisation software

    International Nuclear Information System (INIS)

    Fricke, Harald; Weise, Reiner; Burchert, Wolfgang; Fricke, Eva; Elsner, Andreas; Bolte, Matthias; Domik, Gitta; Hoff, Joerg van den

    2009-01-01

    Aim: Dynamic perfusion PET offers a clinical relevant advantage over myocardial perfusion scintigraphy due to its ability to measure myocardial blood flow quantitatively. This leads to an improved detection of multivessel disease and the possibility to assess not only the culprit lesion but lower grade stenoses as well. For appropriate revascularization, perfusion defects must be matched to coronary lesions. It has been shown that image fusion of morphological and functional images is superior to side-by-side analysis. Still, software for quantitative perfusion PET combined with CT angiography is rare. In this paper we present a new software tool for image fusion and visualization of quantitative perfusion PET and coronary morphology derived from CT angiography. Methods: In our software, a PET uptake image is used for manual co-registration. Co-registration results are then applied to the functional data derived from compartment modelling. To evaluate the reproducibility of the manual co-registration, we calculated the deviation between a series of manual co-registrations performed on nine pairs of unregistered PET and CT datasets by five trained participants. Two dimensional transfer functions were used to highlight the coronary arteries from the CT study in the combined data sets. Results: The average Euclidian distances for three references points were between 3.7 and 4.1 mm. The maximum distance was 10.6 mm. By the use of the two dimensional transfer functions, coronary anatomy could be easily visualised either by user-interaction or automatically by use of neuronal networks. Conclusions: With this approach it is possible to combine quantitative perfusion PET with coronary anatomy derived from CT angiography. Our first experiences indicate that manual image fusion with our tool is reproducible and that visualisation of the combined datasets is achieved within short time. (orig.)

  4. Feasibility of a novel design of high resolution parallax-free Compton enhanced PET scanner dedicated to brain research

    CERN Document Server

    Braem, André; Chesi, Enrico Guido; Correia, J G; Garibaldi, F; Joram, C; Mathot, S; Nappi, E; Ribeiro da Silva, M; Schoenahl, F; Séguinot, Jacques; Weilhammer, P; Zaidi, H

    2004-01-01

    A novel concept for a positron emission tomography (PET) camera module is proposed, which provides full 3D reconstruction with high resolution over the total detector volume, free of parallax errors. The key components are a matrix of long scintillator crystals and hybrid photon detectors (HPDs) with matched segmentation and integrated readout electronics. The HPDs read out the two ends of the scintillator package. Both excellent spatial (x, y, z) and energy resolution are obtained. The concept allows enhancing the detection efficiency by reconstructing a significant fraction of events which underwent Compton scattering in the crystals. The proof of concept will first be demonstrated with yttrium orthoaluminate perovskite (YAP):Ce crystals, but the final design will rely on other scintillators more adequate for PET applications (e.g. LSO:Ce or LaBr /sub 3/:Ce). A promising application of the proposed camera module, which is currently under development, is a high resolution 3D brain PET camera with an axial fi...

  5. Evaluation of an unshielded luminescence flow-through radio-HPLC detector for LC quality control and preparation of PET radiopharmaceuticals

    International Nuclear Information System (INIS)

    Thonon, David; Kaisin, Geoffroy; Henrottin, Jean; Aerts, Joël; Van Malderen, Hans; Luxen, André

    2013-01-01

    Radio-HPLC is an essential method to assess the purity of PET radiopharmaceuticals. The usual NaI scintillator radiodetector requires heavy, costly and cumbersome lead shielding. The luminescence LB 500 fLumo detector has been developed to tackle these drawbacks and achieve high sensitivity. The fLumo uses a photon counting detector combined with a flow-through cell modified with a solid melt-on scintillator only sensitive to the positron. This study demonstrates the usefulness of the fLumo for analysis and purification of PET radiopharmaceuticals. - Highlights: ► We evaluate a novel unshielded luminescence flow-through radio-HPLC detector (fLumo) which is only sensitive to the positron and insensitive to gamma rays for applications in PET radiopharmaceuticals analysis and preparation. ► The fLumo detector exhibits a low limit of detection as activities as low as 4 kBq are detected (HPLC and UPLC radiodetectors). ► The fLumo detector demonstrates excellent linearity (0.2 to 2500 MBq/ml, r 2 >0.995) and reproducibility. ► Thanks to its compactness and absence of shielding, the fLumo has been installed in a production shielded “hot” cell to detect radiocompounds during a semi-preparative HPLC purification. ► This work demonstrates the value of the fLumo luminescence flow-through radio-HPLC detector for applications in PET tracers radiochemistry

  6. Assessment of various strategies for 18F-FET PET-guided delineation of target volumes in high-grade glioma patients

    International Nuclear Information System (INIS)

    Vees, Hansjoerg; Senthamizhchelvan, Srinivasan; Ratib, Osman; Miralbell, Raymond; Weber, Damien C.; Zaidi, Habib

    2009-01-01

    The purpose of the study is to assess the contribution of 18 F-fluoro-ethyl-tyrosine ( 18 F-FET) positron emission tomography (PET) in the delineation of gross tumor volume (GTV) in patients with high-grade gliomas compared with magnetic resonance imaging (MRI) alone. The study population consisted of 18 patients with high-grade gliomas. Seven image segmentation techniques were used to delineate 18 F-FET PET GTVs, and the results were compared to the manual MRI-derived GTV (GTV MRI ). PET image segmentation techniques included manual delineation of contours (GTV man ), a 2.5 standardized uptake value (SUV) cutoff (GTV 2.5 ), a fixed threshold of 40% and 50% of the maximum signal intensity (GTV 40% and GTV 50% ), signal-to-background ratio (SBR)-based adaptive thresholding (GTV SBR ), gradient find (GTV GF ), and region growing (GTV RG ). Overlap analysis was also conducted to assess geographic mismatch between the GTVs delineated using the different techniques. Contours defined using GTV 2.5 failed to provide successful delineation technically in three patients (18% of cases) as SUV max MRI (67% of cases). Yet, PET detected frequently tumors that are not visible on MRI and added substantially tumor extension outside the GTV MRI in six patients (33% of cases). The selection of the most appropriate 18 F-FET PET-based segmentation algorithm is crucial, since it impacts both the volume and shape of the resulting GTV. The 2.5 SUV isocontour and GF segmentation techniques performed poorly and should not be used for GTV delineation. With adequate setting, the SBR-based PET technique may add considerably to conventional MRI-guided GTV delineation. (orig.)

  7. Comparison of {sup 18}F-FET PET and perfusion-weighted MRI for glioma grading. A hybrid PET/MR study

    Energy Technology Data Exchange (ETDEWEB)

    Verger, Antoine [Forschungszentrum Juelich, Institute of Neuroscience and Medicine (INM-3, -4), Juelich (Germany); Lorraine University, Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU Nancy, Nancy (France); Lorraine University, IADI, INSERM, UMR 947, Nancy (France); Filss, Christian P. [Forschungszentrum Juelich, Institute of Neuroscience and Medicine (INM-3, -4), Juelich (Germany); RWTH Aachen University Hospital, Department of Nuclear Medicine, Aachen (Germany); Lohmann, Philipp; Stoffels, Gabriele; Rota Kops, Elena [Forschungszentrum Juelich, Institute of Neuroscience and Medicine (INM-3, -4), Juelich (Germany); Sabel, Michael [University of Duesseldorf, Department of Neurosurgery, Duesseldorf (Germany); Wittsack, Hans J. [University Duesseldorf, Department of Diagnostic and Interventional Radiology, Medical Faculty, Duesseldorf (Germany); Galldiks, Norbert; Fink, Gereon R. [Forschungszentrum Juelich, Institute of Neuroscience and Medicine (INM-3, -4), Juelich (Germany); University of Cologne, Department of Neurology, Cologne (Germany); University of Cologne and Bonn, Center of Integrated Oncology (CIO), Bonn (Germany); Shah, Nadim J. [Forschungszentrum Juelich, Institute of Neuroscience and Medicine (INM-3, -4), Juelich (Germany); RWTH Aachen University Hospital, Department of Neurology, Aachen (Germany); Juelich-Aachen Research Alliance (JARA), Section JARA-Brain, Juelich (Germany); Langen, Karl-Josef [Forschungszentrum Juelich, Institute of Neuroscience and Medicine (INM-3, -4), Juelich (Germany); RWTH Aachen University Hospital, Department of Nuclear Medicine, Aachen (Germany); Juelich-Aachen Research Alliance (JARA), Section JARA-Brain, Juelich (Germany)

    2017-12-15

    Both perfusion-weighted MR imaging (PWI) and O-(2-{sup 18}F-fluoroethyl)-L-tyrosine PET ({sup 18}F-FET) provide grading information in cerebral gliomas. The aim of this study was to compare the diagnostic value of {sup 18}F-FET PET and PWI for tumor grading in a series of patients with newly diagnosed, untreated gliomas using an integrated PET/MR scanner. Seventy-two patients with untreated gliomas [22 low-grade gliomas (LGG), and 50 high-grade gliomas (HGG)] were investigated with {sup 18}F-FET PET and PWI using a hybrid PET/MR scanner. After visual inspection of PET and PWI maps (rCBV, rCBF, MTT), volumes of interest (VOIs) with a diameter of 16 mm were centered upon the maximum of abnormality in the tumor area in each modality and the contralateral unaffected hemisphere. Mean and maximum tumor-to-brain ratios (TBR{sub mean}, TBR{sub max}) were calculated. In addition, Time-to-Peak (TTP) and slopes of time-activity curves were calculated for {sup 18}F-FET PET. Diagnostic accuracies of {sup 18}F-FET PET and PWI for differentiating low-grade glioma (LGG) from high-grade glioma (HGG) were evaluated by receiver operating characteristic analyses (area under the curve; AUC). The diagnostic accuracy of {sup 18}F-FET PET and PWI to discriminate LGG from HGG was similar with highest AUC values for TBR{sub mean} and TBR{sub max} of {sup 18}F-FET PET uptake (0.80, 0.83) and for TBR{sub mean} and TBR{sub max} of rCBV (0.80, 0.81). In case of increased signal in the tumor area with both methods (n = 32), local hot-spots were incongruent in 25 patients (78%) with a mean distance of 10.6 ± 9.5 mm. Dynamic FET PET and combination of different parameters did not further improve diagnostic accuracy. Both {sup 18}F-FET PET and PWI discriminate LGG from HGG with similar diagnostic performance. Regional abnormalities in the tumor area are usually not congruent indicating that tumor grading by {sup 18}F-FET PET and PWI is based on different pathophysiological phenomena. (orig.)

  8. Towards enhanced PET quantification in clinical oncology

    DEFF Research Database (Denmark)

    Zaidi, Habib; Karakatsanis, Nicolas

    2018-01-01

    is still a matter of debate. Quantitative PET has advanced elegantly during the last two decades and is now reaching the maturity required for clinical exploitation, particularly in oncology where it has the capability to open many avenues for clinical diagnosis, assessment of response to treatment...... and therapy planning. Therefore, the preservation and further enhancement of the quantitative features of PET imaging is crucial to ensure that the full clinical value of PET imaging modality is utilized in clinical oncology. Recent advancements in PET technology and methodology have paved the way for faster...... PET acquisitions of enhanced sensitivity to support the clinical translation of highly quantitative 4D parametric imaging methods in clinical oncology. In this report, we provide an overview of recent advances and future trends in quantitative PET imaging in the context of clinical oncology. The pros...

  9. Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification.

    Science.gov (United States)

    Hansen, Adam E; Andersen, Flemming L; Henriksen, Sarah T; Vignaud, Alexandre; Ardenkjaer-Larsen, Jan H; Højgaard, Liselotte; Kjaer, Andreas; Klausen, Thomas L

    2016-12-01

    Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented for a clinical whole-body system using simultaneous (1)H-MRI and PET but never for (13)C-MRSI and PET. Here, the feasibility of simultaneous PET and (13)C-MRSI as well as hyperpolarized (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. Combined PET and (13)C-MRSI phantoms including a NEMA [(18)F]-FDG phantom, (13)C-acetate and (13)C-urea sources, and hyperpolarized (13)C-pyruvate were imaged repeatedly with PET and/or (13)C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET trues; and (13)C-MRSI signal-to-noise ratio (SNR) for urea and acetate phantoms. Differences between measurement conditions were evaluated using t tests. PET and (13)C-MRSI data acquisition could be performed simultaneously without any discernible artifacts. The average difference in PET activity between acquisitions with and without simultaneous (13)C-MRSI was 0.83 (largest sphere) and -0.76 % (background). The average difference in net trues was -0.01 %. The average difference in (13)C-MRSI SNR between acquisitions with and without simultaneous PET ranged from -2.28 to 1.21 % for all phantoms and measurement conditions. No differences were significant. The system was capable of (13)C-MRSI of hyperpolarized (13)C-pyruvate. Simultaneous PET and (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is feasible. Phantom experiments showed that possible interference effects introduced by acquiring data from the two modalities simultaneously are small and non-significant. Further experiments can now investigate the benefits of simultaneous PET and

  10. MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Vontobel, Jan; Liga, Riccardo; Possner, Mathias; Clerc, Olivier F.; Mikulicic, Fran; Veit-Haibach, Patrick; Voert, Edwin E.G.W. ter; Fuchs, Tobias A.; Stehli, Julia; Pazhenkottil, Aju P.; Benz, Dominik C.; Graeni, Christoph; Gaemperli, Oliver; Herzog, Bernhard; Buechel, Ronny R.; Kaufmann, Philipp A. [University Hospital Zurich, Department of Nuclear Medicine, Zurich (Switzerland)

    2015-09-15

    The aim of this study was to evaluate the feasibility of attenuation correction (AC) for cardiac {sup 18}F-labelled fluorodeoxyglucose (FDG) positron emission tomography (PET) using MR-based attenuation maps. We included 23 patients with no known cardiac history undergoing whole-body FDG PET/CT imaging for oncological indications on a PET/CT scanner using time-of-flight (TOF) and subsequent whole-body PET/MR imaging on an investigational hybrid PET/MRI scanner. Data sets from PET/MRI (with and without TOF) were reconstructed using MR AC and semi-quantitative segmental (20-segment model) myocardial tracer uptake (per cent of maximum) and compared to PET/CT which was reconstructed using CT AC and served as standard of reference. Excellent correlations were found for regional uptake values between PET/CT and PET/MRI with TOF (n = 460 segments in 23 patients; r = 0.913; p < 0.0001) with narrow Bland-Altman limits of agreement (-8.5 to +12.6 %). Correlation coefficients were slightly lower between PET/CT and PET/MRI without TOF (n = 460 segments in 23 patients; r = 0.851; p < 0.0001) with broader Bland-Altman limits of agreement (-12.5 to +15.0 %). PET/MRI with and without TOF showed minimal underestimation of tracer uptake (-2.08 and -1.29 %, respectively), compared to PET/CT. Relative myocardial FDG uptake obtained from MR-based attenuation corrected FDG PET is highly comparable to standard CT-based attenuation corrected FDG PET, suggesting interchangeability of both AC techniques. (orig.)

  11. Bayesian reconstruction of photon interaction sequences for high-resolution PET detectors

    Energy Technology Data Exchange (ETDEWEB)

    Pratx, Guillem; Levin, Craig S [Molecular Imaging Program at Stanford, Department of Radiology, Stanford, CA (United States)], E-mail: cslevin@stanford.edu

    2009-09-07

    Realizing the full potential of high-resolution positron emission tomography (PET) systems involves accurately positioning events in which the annihilation photon deposits all its energy across multiple detector elements. Reconstructing the complete sequence of interactions of each photon provides a reliable way to select the earliest interaction because it ensures that all the interactions are consistent with one another. Bayesian estimation forms a natural framework to maximize the consistency of the sequence with the measurements while taking into account the physics of {gamma}-ray transport. An inherently statistical method, it accounts for the uncertainty in the measured energy and position of each interaction. An algorithm based on maximum a posteriori (MAP) was evaluated for computer simulations. For a high-resolution PET system based on cadmium zinc telluride detectors, 93.8% of the recorded coincidences involved at least one photon multiple-interactions event (PMIE). The MAP estimate of the first interaction was accurate for 85.2% of the single photons. This represents a two-fold reduction in the number of mispositioned events compared to minimum pair distance, a simpler yet efficient positioning method. The point-spread function of the system presented lower tails and higher peak value when MAP was used. This translated into improved image quality, which we quantified by studying contrast and spatial resolution gains.

  12. Study of CT-based positron range correction in high resolution 3D PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cal-Gonzalez, J., E-mail: jacobo@nuclear.fis.ucm.es [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Herraiz, J.L. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Espana, S. [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Vicente, E. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Instituto de Estructura de la Materia, Consejo Superior de Investigaciones Cientificas (CSIC), Madrid (Spain); Herranz, E. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Desco, M. [Unidad de Medicina y Cirugia Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Vaquero, J.J. [Dpto. de Bioingenieria e Ingenieria Espacial, Universidad Carlos III, Madrid (Spain); Udias, J.M. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain)

    2011-08-21

    Positron range limits the spatial resolution of PET images and has a different effect for different isotopes and positron propagation materials. Therefore it is important to consider it during image reconstruction, in order to obtain optimal image quality. Positron range distributions for most common isotopes used in PET in different materials were computed using the Monte Carlo simulations with PeneloPET. The range profiles were introduced into the 3D OSEM image reconstruction software FIRST and employed to blur the image either in the forward projection or in the forward and backward projection. The blurring introduced takes into account the different materials in which the positron propagates. Information on these materials may be obtained, for instance, from a segmentation of a CT image. The results of introducing positron blurring in both forward and backward projection operations was compared to using it only during forward projection. Further, the effect of different shapes of positron range profile in the quality of the reconstructed images with positron range correction was studied. For high positron energy isotopes, the reconstructed images show significant improvement in spatial resolution when positron range is taken into account during reconstruction, compared to reconstructions without positron range modeling.

  13. Study of CT-based positron range correction in high resolution 3D PET imaging

    International Nuclear Information System (INIS)

    Cal-Gonzalez, J.; Herraiz, J.L.; Espana, S.; Vicente, E.; Herranz, E.; Desco, M.; Vaquero, J.J.; Udias, J.M.

    2011-01-01

    Positron range limits the spatial resolution of PET images and has a different effect for different isotopes and positron propagation materials. Therefore it is important to consider it during image reconstruction, in order to obtain optimal image quality. Positron range distributions for most common isotopes used in PET in different materials were computed using the Monte Carlo simulations with PeneloPET. The range profiles were introduced into the 3D OSEM image reconstruction software FIRST and employed to blur the image either in the forward projection or in the forward and backward projection. The blurring introduced takes into account the different materials in which the positron propagates. Information on these materials may be obtained, for instance, from a segmentation of a CT image. The results of introducing positron blurring in both forward and backward projection operations was compared to using it only during forward projection. Further, the effect of different shapes of positron range profile in the quality of the reconstructed images with positron range correction was studied. For high positron energy isotopes, the reconstructed images show significant improvement in spatial resolution when positron range is taken into account during reconstruction, compared to reconstructions without positron range modeling.

  14. High resolution PET breast imager with improved detection efficiency

    Science.gov (United States)

    Majewski, Stanislaw

    2010-06-08

    A highly efficient PET breast imager for detecting lesions in the entire breast including those located close to the patient's chest wall. The breast imager includes a ring of imaging modules surrounding the imaged breast. Each imaging module includes a slant imaging light guide inserted between a gamma radiation sensor and a photodetector. The slant light guide permits the gamma radiation sensors to be placed in close proximity to the skin of the chest wall thereby extending the sensitive region of the imager to the base of the breast. Several types of photodetectors are proposed for use in the detector modules, with compact silicon photomultipliers as the preferred choice, due to its high compactness. The geometry of the detector heads and the arrangement of the detector ring significantly reduce dead regions thereby improving detection efficiency for lesions located close to the chest wall.

  15. On the relevance of the micromechanics approach for predicting the linear viscoelastic behavior of semi-crystalline poly(ethylene)terephtalates (PET)

    International Nuclear Information System (INIS)

    Diani, J.; Bedoui, F.; Regnier, G.

    2008-01-01

    The relevance of micromechanics modeling to the linear viscoelastic behavior of semi-crystalline polymers is studied. For this purpose, the linear viscoelastic behaviors of amorphous and semi-crystalline PETs are characterized. Then, two micromechanics modeling methods, which have been proven in a previous work to apply to the PET elastic behavior, are used to predict the viscoelastic behavior of three semi-crystalline PETs. The microstructures of the crystalline PETs are clearly defined using WAXS techniques. Since microstructures and mechanical properties of both constitutive phases (the crystalline and the amorphous) are defined, the simulations are run without adjustable parameters. Results show that the models are unable to reproduce the substantial decrease of viscosity induced by the increase of crystallinity. Unlike the real materials, for moderate crystallinity, both models show materials of viscosity nearly identical to the amorphous material

  16. Motion compensation for fully 4D PET reconstruction using PET superset data

    Energy Technology Data Exchange (ETDEWEB)

    Verhaeghe, J; Gravel, P; Mio, R; Fukasawa, R; Rosa-Neto, P; Soucy, J-P; Thompson, C J; Reader, A J, E-mail: jeroen.verhaeghe@mcgill.c [Montreal Neurological Institute, McGill University, Montreal (Canada)

    2010-07-21

    Fully 4D PET image reconstruction is receiving increasing research interest due to its ability to significantly reduce spatiotemporal noise in dynamic PET imaging. However, thus far in the literature, the important issue of correcting for subject head motion has not been considered. Specifically, as a direct consequence of using temporally extensive basis functions, a single instance of movement propagates to impair the reconstruction of multiple time frames, even if no further movement occurs in those frames. Existing 3D motion compensation strategies have not yet been adapted to 4D reconstruction, and as such the benefits of 4D algorithms have not yet been reaped in a clinical setting where head movement undoubtedly occurs. This work addresses this need, developing a motion compensation method suitable for fully 4D reconstruction methods which exploits an optical tracking system to measure the head motion along with PET superset data to store the motion compensated data. List-mode events are histogrammed as PET superset data according to the measured motion, and a specially devised normalization scheme for motion compensated reconstruction from the superset data is required. This work proceeds to propose the corresponding time-dependent normalization modifications which are required for a major class of fully 4D image reconstruction algorithms (those which use linear combinations of temporal basis functions). Using realistically simulated as well as real high-resolution PET data from the HRRT, we demonstrate both the detrimental impact of subject head motion in fully 4D PET reconstruction and the efficacy of our proposed modifications to 4D algorithms. Benefits are shown both for the individual PET image frames as well as for parametric images of tracer uptake and volume of distribution for {sup 18}F-FDG obtained from Patlak analysis.

  17. Pet Allergy Quiz

    Science.gov (United States)

    ... Treatments ▸ Allergies ▸ Pet Allergy ▸ Pet Allergy Quiz Share | Pet Allergy Quiz More than half of U.S. households ... cat family. Yet, millions of people suffer from pet allergies. Take this quiz to test your knowledge ...

  18. Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.

    Science.gov (United States)

    Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra

    2017-04-01

    Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.

  19. A small animal PET based on GAPDs and charge signal transmission approach for hybrid PET-MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jihoon; Choi, Yong; Hong, Key Jo; Hu, Wei; Jung, Jin Ho; Huh, Yoonsuk [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Kim, Byung-Tae, E-mail: ychoi.image@gmail.com [Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of)

    2011-08-15

    Positron emission tomography (PET) employing Geiger-mode avalanche photodiodes (GAPDs) and charge signal transmission approach was developed for small animal imaging. Animal PET contained 16 LYSO and GAPD detector modules that were arranged in a 70 mm diameter ring with an axial field of view of 13 mm. The GAPDs charge output signals were transmitted to a preamplifier located remotely using 300 cm flexible flat cables. The position decoder circuits (PDCs) were used to multiplex the PET signals from 256 to 4 channels. The outputs of the PDCs were digitized and further-processed in the data acquisition unit. The cross-compatibilities of the PET detectors and MRI were assessed outside and inside the MRI. Experimental studies of the developed full ring PET were performed to examine the spatial resolution and sensitivity. Phantom and mouse images were acquired to examine the imaging performance. The mean energy and time resolution of the PET detector were 17.6% and 1.5 ns, respectively. No obvious degradation on PET and MRI was observed during simultaneous PET-MRI data acquisition. The measured spatial resolution and sensitivity at the CFOV were 2.8 mm and 0.7%, respectively. In addition, a 3 mm diameter line source was clearly resolved in the hot-sphere phantom images. The reconstructed transaxial PET images of the mouse brain and tumor displaying the glucose metabolism patterns were imaged well. These results demonstrate GAPD and the charge signal transmission approach can allow the development of high performance small animal PET with improved MR compatibility.

  20. TOF-PET/MR和TOF-PET/CT在体部恶性肿瘤SUVmax值的比较%Comparision of SUVmax of TOF-PET/MR and TOF-PET/CT in body malignant tumor

    Institute of Scientific and Technical Information of China (English)

    宋天彬; 卢洁; 崔碧霄; 马杰; 杨宏伟; 马蕾; 梁志刚

    2017-01-01

    目的 探讨时间飞行(TOF)技术PET/CT和PET/MR检查体部恶性病变SUVmax值的一致性.方法 回顾性分析接受TOF-PET/CT和TOF-PET/MR检查的体部恶性肿瘤患者20例,分为先PET/CT后PET/MR组和先PET/MR后PET/CT组,每组10例.采用Bland-Altma图评价两次检查病灶SUVmax值的一致性,采用多因素方差分析评价扫描顺序和机器类型对病灶的SUVmax测量值的影响.结果 TOF-PET/CT与TOF-PET/MR检查病灶的SUVmax值有较好的一致性[先PET/CT后PET/MR组:均值差为3.06,95%CI(-7.5,13.6),先PET/MR后PET/CT组:均值差3.0,95%CI(-2.4,8.3)].扫描顺序对于恶性病灶的SUVmax有影响(F=46.00,P<0.001),而机器类型对恶性病灶的SUVmax值无影响(F=0.005,P=0.95).结论 TOF-PET/MR和TOF-PET/CT在体部恶性病变SUVmax值测量方面具有相当的诊断价值,且延迟显像SUVmax的增加与采集时间有关,而与检查机器类型无关.%Objective To explore the consistency of time-of-flight (TOF) technology of PET/MRI and PET/CT for max standardized uptake value (SUVmax) of body malignant tumors.Methods A retrospective analysis of TOF-PET/CT and TOF-PET/MR imaging data about twenty patients with body malignant tumors was performed.Patients were divided into two groups (each n=10),including PET/CT first and sequentially PET/MR group and PET/MR first and sequentially PET/CT group.Bland-Altman figure was used to evaluate consistency of SUVmax of malignant lesions between TOF-PET/CT and TOF-PET/MR.Multi-way ANOVA was used to analysis effect of machine type and exam order on SUVmaxof malignant lesions in TOF-PET/CT and TOF-PET/MR.Results SUVmax of malignant lesions in TOF-PET/CT and TOF-PET/MR had good consistency in two groups (PET/CT first and sequentially PET/MR group:Mean difference was 3.06,95%CI was [-7.5,13.6];PET/MR first and sequentially PET/CT group:Mean difference was 3.0,95%CI was [-2.4,8.3]).SUVmax was not influenced by machine type (F=0.005,P=0.95),but exam order (F=46.00,P<0

  1. Variability in "1"8F-FDG PET/CT methodology of acquisition, reconstruction and analysis for oncologic imaging: state survey

    International Nuclear Information System (INIS)

    Fischer, Andreia C.F. da S.; Druzian, Aline C.; Bacelar, Alexandre; Pianta, Diego B.; Silva, Ana M. Marques da

    2016-01-01

    The SUV in "1"8F-FDG PET/CT oncological imaging is useful for cancer diagnosis, staging and treatment assessment. There are, however, several factors that can give rise to bias in SUV measurements. When using SUV as a diagnostic tool, one needs to minimize the variability in this measurement by standardization of patient preparation, acquisition and reconstruction parameters. The aim of this study is to evaluate the methodological variability in PET/CT acquisition in Rio Grande do Sul State. For that, in each department, a questionnaire was applied to survey technical information from PET/CT systems and about the acquisitions and analysis methods utilized. All departments implement quality assurance programs consistent with (inter)national recommendations. However, the acquisition and reconstruction methods of acquired PET data differ. The implementation of a harmonized strategy for quantifying the SUV is suggested, in order to obtain greater reproducibility and repeatability. (author)

  2. High diversity of Staphylococcus aureus and Staphylococcus pseudintermedius lineages and toxigenic traits in healthy pet-owning household members. Underestimating normal household contact?

    Science.gov (United States)

    Gómez-Sanz, Elena; Torres, Carmen; Lozano, Carmen; Zarazaga, Myriam

    2013-01-01

    Forty-three unrelated pet-owning households were screened in Spain to study the Staphylococcus aureus and Staphylococcus pseudintermedius nasal carriage, their genetic lineages and virulence traits. Sixty-seven healthy owners and 66 healthy pets were investigated. Isolates characterization was performed and potential interspecies transmission was assessed. S. aureus was present in 51.2% of households studied while S. pseudintermedius in 30.2%. Twenty-eight owners (41.8%) carried S. aureus: one methicillin-resistant S. aureus (MRSA) [t5173-ST8-SCCmecIVa] and 27 methicillin-susceptible S. aureus (MSSA). Three owners (4.5%) were colonized by methicillin-susceptible S. pseudintermedius (MSSP). Fifteen pets (22.7%) carried S. pseudintermedius: two methicillin-resistant S. pseudintermedius (MRSP) [ST71-SCCmecII/III; ST92-SCCmecV] and 13 MSSP; in addition, 8 pets (12.1%) presented MSSA. High diversity of spa and sequence types (STs) was detected. Typical livestock-associated S. aureus lineages (CC398, CC9) were observed in humans and/or companion animals and hospital and/or community-acquired S. aureus lineages (CC45, CC121, CC5, CC8) were detected among pets. Almost 40% of S. pseudintermedius were multidrug-resistant. S. aureus isolates harboured a remarkable high number of virulence genes. The expA gene was detected in 3 S. pseudintermedius isolates. Identical strains from both owners and their pets were identified in 5 households (11.6%): (a) four MSSA (t073-ST45/CC45, t159-ST121/CC121, t209-ST109/CC9, t021-ST1654([new])/singleton) and (b) one multidrug-resistant MSSP (ST142([new])). Highly clonally diverse and toxigenic S. aureus and S. pseudintermedius are common colonizers of healthy humans and pets. The presence of these bacterial species, virulence genes, and interspecies transmission detected, points out to consider pet ownership as a risk factor to acquire, maintain and spread, potential pathogenic bacteria. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Particle identification with Polyethylene Terephthalate (PET) detector with high detection threshold

    Science.gov (United States)

    Dey, S.; Maulik, A.; Raha, Sibaji; Saha, Swapan K.; Syam, D.

    2014-10-01

    In the present work we describe the results of studies, using accelerator data, to determine the accuracy with which particles can be identified and their energies determined with a commercially available polymer (PET) used as a Nuclear Track Detector (NTD). The achieved charge resolution was ± 1 . The initial energy of stopping particle in PET was determined with an accuracy of 10 % for ion energies above the Bragg peak.

  4. Particle identification with Polyethylene Terephthalate (PET) detector with high detection threshold

    Energy Technology Data Exchange (ETDEWEB)

    Dey, S. [Centre for Astroparticle Physics and Space Science, Bose Institute, Kolkata 700 091 (India); Maulik, A., E-mail: atanu.maulik@gmail.com [Centre for Astroparticle Physics and Space Science, Bose Institute, Kolkata 700 091 (India); Raha, Sibaji; Saha, Swapan K. [Centre for Astroparticle Physics and Space Science, Bose Institute, Kolkata 700 091 (India); Department of Physics, Bose Institute, Kolkata 700 009 (India); Syam, D. [Department of Physics, Barasat Government College, Kolkata 700 124 (India)

    2014-10-01

    In the present work we describe the results of studies, using accelerator data, to determine the accuracy with which particles can be identified and their energies determined with a commercially available polymer (PET) used as a Nuclear Track Detector (NTD). The achieved charge resolution was ±1. The initial energy of stopping particle in PET was determined with an accuracy of 10% for ion energies above the Bragg peak.

  5. Four-layer depth-of-interaction PET detector for high resolution PET using a multi-pixel S8550 avalanche photodiode

    Energy Technology Data Exchange (ETDEWEB)

    Nishikido, Fumihiko, E-mail: funis@nirs.go.j [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Inadama, Naoko [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Oda, Ichiro [Shimadzu Corporation, Nishinokyo Kuwabaracho 1 Nakagyo-ku, Kyoto-shi, Kyoto 604-8511 (Japan); Shibuya, Kengo; Yoshida, Eiji; Yamaya, Taiga [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Kitamura, Keishi [Shimadzu Corporation, Nishinokyo Kuwabaracho 1 Nakagyo-ku, Kyoto-shi, Kyoto 604-8511 (Japan); Murayama, Hideo [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2010-09-21

    Avalanche photodiodes (APDs) are being used as photodetectors in positron emission tomography (PET) because they have many advantages over photomultipliers (PMTs) typically used in PET detectors. We have developed a PET detector that consists of a multi-pixel APD and a 6x6x4 array of 1.46x1.46 mm{sup 2}x4.5 m LYSO crystals for a small animal PET scanner. The detector can identify four-layer depth of interaction (DOI) with a position-sensitive APD coupled to the backside of a crystal array by just an optimized reflector arrangement. Since scintillation lights are shared among many pixels by the method, weaker signals in APD pixels far from the interacting crystals are affected by noise. To evaluate the performance of the four-layer DOI detector with the APD and the influence of electrical noise on our method, we constructed a prototype DOI detector and tested its performance. We found, except for crystal elements on the edge of the crystal array, all crystal elements could be identified from the 2D position histogram. An energy resolution of 16.9% was obtained for the whole crystal array of the APD detector. The results of noise dependence of detector performances indicated that the DOI detector using the APD could achieve sufficient performance even when using application-specific integrated circuits.

  6. Four-layer depth-of-interaction PET detector for high resolution PET using a multi-pixel S8550 avalanche photodiode

    International Nuclear Information System (INIS)

    Nishikido, Fumihiko; Inadama, Naoko; Oda, Ichiro; Shibuya, Kengo; Yoshida, Eiji; Yamaya, Taiga; Kitamura, Keishi; Murayama, Hideo

    2010-01-01

    Avalanche photodiodes (APDs) are being used as photodetectors in positron emission tomography (PET) because they have many advantages over photomultipliers (PMTs) typically used in PET detectors. We have developed a PET detector that consists of a multi-pixel APD and a 6x6x4 array of 1.46x1.46 mm 2 x4.5 m LYSO crystals for a small animal PET scanner. The detector can identify four-layer depth of interaction (DOI) with a position-sensitive APD coupled to the backside of a crystal array by just an optimized reflector arrangement. Since scintillation lights are shared among many pixels by the method, weaker signals in APD pixels far from the interacting crystals are affected by noise. To evaluate the performance of the four-layer DOI detector with the APD and the influence of electrical noise on our method, we constructed a prototype DOI detector and tested its performance. We found, except for crystal elements on the edge of the crystal array, all crystal elements could be identified from the 2D position histogram. An energy resolution of 16.9% was obtained for the whole crystal array of the APD detector. The results of noise dependence of detector performances indicated that the DOI detector using the APD could achieve sufficient performance even when using application-specific integrated circuits.

  7. PET/CT in radiation therapy planning; PET/CT in der Strahlentherapieplanung

    Energy Technology Data Exchange (ETDEWEB)

    Grosu, A.L. [Klinik und Poliklinik fuer Strahlentherapie und Radiologische Onkologie, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany); Krause, B.J. [Klinik fuer Nuklearmedizin, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany); Nestle, U. [Klinik fuer Nuklearmedizin, Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany)

    2006-09-15

    Regarding treatment planning in radiotherapy PET offers advantages in terms of tumor delineation and the description of biological processes. To define the real impact of this investigation in radiation treatment planning, following experimental, clinical and cost/benefit analysis are required. FDG-PET has a significant impact on GTV and PTV delineation in lung cancer and can detect lymph node involvement and differentiation of malignant tissue from atelectasis. In high-grade gliomas and meningiomas, methionine-PET helps to define the GTV and differentiate tumor from normal tissue. In head and neck cancer, cervix cancer and prostate cancer the value of FDG-PET for radiation treatment planning is still under investigation. For example, FDG-PET can be superior to CT and MRI in the detection of lymph node metastases in head and neck, unknown primary cancer and differentiation of viable tumor tissue after treatment. Therefore, it could play an important role in GTV definition and sparing of normal tissue. For other entities like gastro-intestinal cancer, lymphomas, sarcoma etc., the data of the literature are yet insufficient. The imaging of hypoxia, cell proliferation, angiogenesis, apoptosis and gene expression leads to the identification of different areas of a biologically heterogeneous tumor mass that can be individually targeted using IMRT. In addition, a biological dose distribution can be generated, the so-called dose painting. However, systematical experimental and clinical trials are necessary to validate this hypothesis. (orig.)

  8. Semi-Supervised Tripled Dictionary Learning for Standard-dose PET Image Prediction using Low-dose PET and Multimodal MRI

    Science.gov (United States)

    Wang, Yan; Ma, Guangkai; An, Le; Shi, Feng; Zhang, Pei; Lalush, David S.; Wu, Xi; Pu, Yifei; Zhou, Jiliu; Shen, Dinggang

    2017-01-01

    Objective To obtain high-quality positron emission tomography (PET) image with low-dose tracer injection, this study attempts to predict the standard-dose PET (S-PET) image from both its low-dose PET (L-PET) counterpart and corresponding magnetic resonance imaging (MRI). Methods It was achieved by patch-based sparse representation (SR), using the training samples with a complete set of MRI, L-PET and S-PET modalities for dictionary construction. However, the number of training samples with complete modalities is often limited. In practice, many samples generally have incomplete modalities (i.e., with one or two missing modalities) that thus cannot be used in the prediction process. In light of this, we develop a semi-supervised tripled dictionary learning (SSTDL) method for S-PET image prediction, which can utilize not only the samples with complete modalities (called complete samples) but also the samples with incomplete modalities (called incomplete samples), to take advantage of the large number of available training samples and thus further improve the prediction performance. Results Validation was done on a real human brain dataset consisting of 18 subjects, and the results show that our method is superior to the SR and other baseline methods. Conclusion This work proposed a new S-PET prediction method, which can significantly improve the PET image quality with low-dose injection. Significance The proposed method is favorable in clinical application since it can decrease the potential radiation risk for patients. PMID:27187939

  9. 18F-DOPA PET/CT for assessment of response to induction chemotherapy in a child with high-risk neuroblastoma

    International Nuclear Information System (INIS)

    Piccardo, Arnoldo; Lopci, Egesta; Foppiani, Luca; Morana, Giovanni; Conte, Massimo

    2014-01-01

    Functional imaging plays a crucial role in the assessment of neuroblastoma. The evaluation of response to induction chemotherapy is a cornerstone in scheduling proper treatment management in patients affected by high-risk neuroblastoma. 123 I-metaiodobenzylguanidine has been recognized as the radiopharmaceutical of choice in neuroblastoma assessment. To date, the clinical role of PET/CT in pediatric malignancy is not well established. 18 F-DOPA-PET/CT has been recently used in neuroblastoma, and compared with 123 I-MIBG-scan. Scant new data are available about the role of this tool in the evaluation of treatment response after induction chemotherapy. We investigate the role of 18 F-DOPA-PET/CT in characterizing the response to induction chemotherapy in a child affected by high-risk-neuroblastoma, in whom the rare association of 123 I-MIBG-negative primary tumor and MIBG-positive bone marrow metastases was observed. (orig.)

  10. Current opinion on PET for gastrointestinal tumors

    International Nuclear Information System (INIS)

    Diederichs, C.G.; Schirrmeister, H.; Staib, L.

    2000-01-01

    The benefit of FDG-PET for restaging of colorectal carcinoma and for the differentiation of indeterminate hepatic lesions is well-documented. Accuracies of FDG-PET for recurrence, lymph node status and the detection of distant metastases are higher compared with computed tomography, for example. For other epithelial gastrointestinal tumors similar results have also been demonstrated in smaller trials or case presentations. The differentiation of recurrent rectal carcinoma from scar and PET for endocrine tumors are described elsewhere (Der Nuklearmediziner PET II, in preparation). Almost no data exist for rare tumors like anal carcinoma or tumors of the small intestines. For hepatocellular carcinoma, FDG-PET has a high positive predictive value, and the intensity of the uptake correlates well with grading. However, FDG-PET is not suitable for the exclusion of hepatocellular carcinoma due to insufficient sensitivity. The differentiation of benign and malignant pancreatic masses works well for selected patients. FDG-PET for lymph node staging is at least as accurate as conventional staging, and for the detection of distant metastases FDG-PET is superior compared with conventional staging. Few data exist on therapy control of gastrointestinal tumors. (orig.) [de

  11. Who wants cancer screening with PET?

    International Nuclear Information System (INIS)

    Yasunaga, Hideo

    2009-01-01

    Objectives: Cancer screening using whole-body fluorodeoxyglucose-positron emission tomography (FDG-PET) has gradually become popular in Japan. Although some studies have reported high cancer detection rates with PET screening, the justification for such an approach is still unclear, and no evidence has been provided to indicate that PET screening reduces cancer mortality. We measured the general public's willingness to pay (WTP) for this service using a contingent valuation method, after providing them with sufficient information regarding the efficacy and limitations of the service. Methods: A computer-assisted questionnaire survey was conducted on males and females in Japan aged between 40 and 59 years. The study participants (n = 390) were provided with sufficient information about the PET procedure, the high cancer detection rate, false-negatives/false-positives and the fact that the mortality-reducing effect of PET screening has not yet been demonstrated. The participants' WTP was ascertained by a double-bound dichotomous choice approach. Results: The average WTP among all the participants was $68.0 (95% confidence interval: $56.9-79.2). A Weibull regression analysis showed that income, degree of concern about health, and family history of cancer were significant factors affecting WTP. Conclusions: The actual charge for PET screening in Japan is approximately $1000 on average, which is significantly higher than the participants' WTP for the actual benefit obtained from the service. If the Japanese healthcare consumers are well-informed, most of them would avoid purchasing such a costly service.

  12. Implementation and performance of an optical motion tracking system for high resolution brain PET imaging

    Science.gov (United States)

    Lopresti, B. J.; Russo, A.; Jones, W. F.; Fisher, T.; Crouch, D. G.; Altenburger, D. E.; Townsend, D. W.

    1999-12-01

    Head motion during PET scanning is widely regarded as a source of image degradation and resolution loss. Recent improvements in the spatial resolution of state-of-the-art tomographs may be compromised by patient motion during scanning, as these high resolution data will be increasingly susceptible to smaller movements of the head. The authors have developed an opto-electronic motion tracking system based on commercially-available technology that is capable of very accurate real-time measurements of the position and orientation of the patient's head. These positions are transformed to the reference frame of the PET scanner, and could potentially be used to provide motion correction of list-mode emission data on an event-by-event basis.

  13. Diagnostic value of [18F] FDG-PET and PET/CT in urinary bladder cancer: a meta-analysis.

    Science.gov (United States)

    Zhang, Huojun; Xing, Wei; Kang, Qinqin; Chen, Chao; Wang, Linhui; Lu, Jianping

    2015-05-01

    An early diagnosis of urinary bladder cancer is crucial for early treatment and management. The objective of this systematic review was to assess the overall diagnostic accuracy of 18 F FDG-PET and PET/CT in urinary bladder cancer with meta-analysis. The PubMed and CNKI databases were searched for the eligible studies published up to June 01, 2014. The sensitivity, specificity, and other measures of accuracy of 18 F FDG-PET and PET/CT in the diagnosis of urinary bladder cancer were pooled along with 95 % confidence intervals (CI). Summary receiver operating characteristic (ROC) curves were used to summarize overall test performance. Ten studies met our inclusion criteria. The summary estimates for 18 F FDG-PET and PET/CT in the diagnosis of urinary bladder cancer in meta-analysis were as follows: a pooled sensitivity, 0.82 (95 % confidence interval [CI], 0.75 to 0.88); a pooled specificity, 0.92 (95 % CI, 0.87 to 0.95); positive likelihood ratio, 6.80 (95 % CI, 4.31 to 10.74); negative likelihood ratio, 0.27 (95 % CI, 0.19 to 0.36); and diagnostic odds ratio, 25.18 (95 % CI, 17.58 to 70.4). The results indicate that 18 F FDG-PET and PET/CT are relatively high sensitive and specific for the diagnosis of urinary bladder cancer.

  14. Effect of Attenuation Correction on Regional Quantification Between PET/MR and PET/CT

    DEFF Research Database (Denmark)

    Teuho, Jarmo; Johansson, Jarkko; Linden, Jani

    2016-01-01

    UNLABELLED: A spatial bias in brain PET/MR exists compared with PET/CT, because of MR-based attenuation correction. We performed an evaluation among 4 institutions, 3 PET/MR systems, and 4 PET/CT systems using an anthropomorphic brain phantom, hypothesizing that the spatial bias would be minimized....../MR systems, CTAC was applied as the reference method for attenuation correction. RESULTS: With CTAC, visual and quantitative differences between PET/MR and PET/CT systems were minimized. Intersystem variation between institutions was +3.42% to -3.29% in all VOIs for PET/CT and +2.15% to -4.50% in all VOIs...... for PET/MR. PET/MR systems differed by +2.34% to -2.21%, +2.04% to -2.08%, and -1.77% to -5.37% when compared with a PET/CT system at each institution, and these differences were not significant (P ≥ 0.05). CONCLUSION: Visual and quantitative differences between PET/MR and PET/CT systems can be minimized...

  15. Quantitative PET imaging with the 3T MR-BrainPET

    International Nuclear Information System (INIS)

    Weirich, C.; Scheins, J.; Lohmann, P.; Tellmann, L.; Byars, L.; Michel, C.; Rota Kops, E.; Brenner, D.; Herzog, H.; Shah, N.J.

    2013-01-01

    The new hybrid imaging technology of MR-PET allows for simultaneous acquisition of versatile MRI contrasts and the quantitative metabolic imaging with PET. In order to achieve the quantification of PET images with minimal residual error the application of several corrections is crucial. In this work we present our results on quantification with the 3T MR BrainPET scanner

  16. Brain PET scan

    Science.gov (United States)

    ... results on a PET scan. Blood sugar or insulin levels may affect the test results in people with diabetes . PET scans may be done along with a CT scan. This combination scan is called a PET/CT. Alternative Names Brain positron emission tomography; PET scan - brain References Chernecky ...

  17. Thoracic staging in lung cancer: prospective comparison of 18F-FDG PET/MR imaging and 18F-FDG PET/CT.

    Science.gov (United States)

    Heusch, Philipp; Buchbender, Christian; Köhler, Jens; Nensa, Felix; Gauler, Thomas; Gomez, Benedikt; Reis, Henning; Stamatis, Georgios; Kühl, Hilmar; Hartung, Verena; Heusner, Till A

    2014-03-01

    /MR imaging exhibited a high correlation (R = 0.74 and 0.86, respectively; P dedicated pulmonary MR imaging protocol, compared with (18)F-FDG PET/CT, does not provide advantages in thoracic staging in NSCLC patients.

  18. FDG PET/CT in cancer

    DEFF Research Database (Denmark)

    Petersen, Henrik; Holdgaard, Paw Christian; Madsen, Poul Henning

    2016-01-01

    PURPOSE: The Region of Southern Denmark (RSD), covering 1.2 of Denmark's 5.6 million inhabitants, established a task force to (1) retrieve literature evidence for the clinical use of positron emission tomography (PET)/CT and provide consequent recommendations and further to (2) compare the actual...... use of PET/CT in the RSD with these recommendations. This article summarizes the results. METHODS: A Work Group appointed a professional Subgroup which made Clinician Groups conduct literature reviews on six selected cancers responsible for 5,768 (62.6 %) of 9,213 PET/CT scans in the RSD in 2012...... use of PET/CT and literature-based recommendations was high in the first five mentioned cancers in that 96.2 % of scans were made for grade A or B indications versus only 22.2 % in gynaecological cancers. CONCLUSION: Evidence-based usefulness was reported in five of six selected cancers; evidence...

  19. Clinical PET application

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Moo; Hong, Song W.; Choi, Chang W.; Yang, Seong Dae [Korea Cancer Center Hospital, Seoul (Korea)

    1997-12-01

    PET gives various methabolic images, and is very important, new diagnostic modality in clinical oncology. In Korea Cancer Center Hospital, PET is installed as a research tool of long-mid-term atomic research project. For the efficient use of PET for clinical and research projects, income from the patients should be managed to get the raw material, equipment, manpower, and also for the clinical PET research. 1. Support the clinical application of PET in oncology. 2. Budgetary management of income, costs for raw material, equipment, manpower, and the clinical PET research project. In this year, 250 cases of PET images were obtained, which resulted total income of 180,000,000 won. 50,000,000 won was deposited for the 1998 PET clinical research. Second year PET clinical research should be managed under unified project. Increased demand for {sup 18}FDG in and outside KCCH need more than 2 times production of {sup 18}FDG in a day purchase of HPLC pump and {sup 68}Ga pin source which was delayed due to economic crisis, should be done early in 1998. (author). 2 figs., 3 tabs.

  20. Predicting standard-dose PET image from low-dose PET and multimodal MR images using mapping-based sparse representation

    International Nuclear Information System (INIS)

    Wang, Yan; Zhou, Jiliu; Zhang, Pei; An, Le; Ma, Guangkai; Kang, Jiayin; Shi, Feng; Shen, Dinggang; Wu, Xi; Lalush, David S; Lin, Weili

    2016-01-01

    Positron emission tomography (PET) has been widely used in clinical diagnosis for diseases and disorders. To obtain high-quality PET images requires a standard-dose radionuclide (tracer) injection into the human body, which inevitably increases risk of radiation exposure. One possible solution to this problem is to predict the standard-dose PET image from its low-dose counterpart and its corresponding multimodal magnetic resonance (MR) images. Inspired by the success of patch-based sparse representation (SR) in super-resolution image reconstruction, we propose a mapping-based SR (m-SR) framework for standard-dose PET image prediction. Compared with the conventional patch-based SR, our method uses a mapping strategy to ensure that the sparse coefficients, estimated from the multimodal MR images and low-dose PET image, can be applied directly to the prediction of standard-dose PET image. As the mapping between multimodal MR images (or low-dose PET image) and standard-dose PET images can be particularly complex, one step of mapping is often insufficient. To this end, an incremental refinement framework is therefore proposed. Specifically, the predicted standard-dose PET image is further mapped to the target standard-dose PET image, and then the SR is performed again to predict a new standard-dose PET image. This procedure can be repeated for prediction refinement of the iterations. Also, a patch selection based dictionary construction method is further used to speed up the prediction process. The proposed method is validated on a human brain dataset. The experimental results show that our method can outperform benchmark methods in both qualitative and quantitative measures. (paper)

  1. Properties of PET/PLA Electrospun Blends

    Science.gov (United States)

    Li, Kevin; Cebe, Peggy

    2012-02-01

    Electrospun membranes were fabricated from poly(ethylene terephthalate), PET, co-spun with poly(lactic acid), PLA. The PLA contained 2% of the D-isomer, which served to limit the overall degree of crystallinity. Membranes were deposited from blended solutions of PET/PLA in hexafluoroisopropanol. The PET/PLA composition ranged from 0/100, 75/25, 50/50, 25/75, and 100/0. Electrospun membranes were made using either a static flat plate or a rotating wheel as the counter electrode, yielding unoriented mats or highly oriented tapes, respectively. We report on our investigation of the crystallinity, crystal perfection, and mechanical properties of these materials using differential scanning calorimetry, wide and small angle X-ray scattering, and dynamic mechanical analysis. In particular, we study the ability of one blend component (PET) to crystallize in the presence of existing crystals of the second blend component (PLA) which crystallizes first and at a lower temperature than PET.

  2. PET and PET/CT in oncology: the key of diagnostic challenge

    International Nuclear Information System (INIS)

    Mortelmans, L.; Stroobants, S.; Spaepen, K.

    2004-01-01

    In this presentation authors present use of positron emission tomography (PET) in oncology. This lecture is divided to the following parts: (1) Assessment of treatment response; (2) Treatment monitoring by PET: clinical examples; (3) PET for early response assessment; (4) Use of PET in Radiotherapy planning

  3. High-resolution imaging of pulmonary ventilation and perfusion with {sup 68}Ga-VQ respiratory gated (4-D) PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Callahan, Jason [Centre for Molecular Imaging, Peter MacCallum Cancer Centre, East Melbourne, VIC (Australia); Hofman, Michael S. [The University of Melbourne, Department of Medicine, Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne, VIC (Australia); Siva, Shankar [The University of Melbourne, Peter MacCallum Cancer Centre, Department of Radiation Oncology, East Melbourne, VIC (Australia); The University of Melbourne, Sir Peter MacCallum Department of Oncology, East Melbourne, VIC (Australia); Kron, Tomas [The University of Melbourne, Sir Peter MacCallum Department of Oncology, East Melbourne, VIC (Australia); The University of Melbourne, Peter MacCallum Cancer Centre, Department of Physical Sciences, East Melbourne, VIC (Australia); Schneider, Michal E. [Monash University, Department of Medical Imaging and Radiation Science, Clayton, VIC (Australia); Binns, David; Eu, Peter [Peter MacCallum Cancer Centre, Centre for Cancer Imaging, East Melbourne, VIC (Australia); Hicks, Rodney J. [The University of Melbourne, Sir Peter MacCallum Department of Oncology, Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne, VIC (Australia)

    2014-02-15

    Our group has previously reported on the use of {sup 68}Ga-ventilation/perfusion (VQ) PET/CT scanning for the diagnosis of pulmonary embolism. We describe here the acquisition methodology for {sup 68}Ga-VQ respiratory gated (4-D) PET/CT and the effects of respiratory motion on image coregistration in VQ scanning. A prospective study was performed in 15 patients with non-small-cell lung cancer. 4-D PET and 4-D CT images were acquired using an infrared marker on the patient's abdomen as a surrogate for breathing motion following inhalation of Galligas and intravenous administration of {sup 68}Ga-macroaggregated albumin. Images were reconstructed with phase-matched attenuation correction. The lungs were contoured on CT and PET VQ images during free-breathing (FB) and at maximum inspiration (Insp) and expiration (Exp). The similarity between PET and CT volumes was measured using the Dice coefficient (DC) comparing the following groups; (1) FB-PET/CT, (2) InspPET/InspCT, (3) ExpPET/Exp CT, and (4) FB-PET/AveCT. A repeated measures one-way ANOVA with multiple comparison Tukey tests were performed to evaluate any difference between the groups. Diaphragmatic motion in the superior-inferior direction on the 4-D CT scan was also measured. 4-D VQ scanning was successful in all patients without additional acquisition time compared to the nongated technique. The highest volume overlap was between ExpPET and ExpCT and between FB-PET and AveCT with a DC of 0.82 and 0.80 for ventilation and perfusion, respectively. This was significantly better than the DC comparing the other groups (0.78-0.79, p < 0.05). These values agreed with a visual inspection of the images with improved image coregistration around the lung bases. The diaphragmatic motion during the 4-D CT scan was highly variable with a range of 0.4-3.4 cm (SD 0.81 cm) in the right lung and 0-2.8 cm (SD 0.83 cm) in the left lung. Right-sided diaphragmatic nerve palsy was observed in 3 of 15 patients. {sup 68}Ga-VQ 4-D

  4. Temperature dependence of APD-based PET scanners

    International Nuclear Information System (INIS)

    Keereman, Vincent; Van Holen, Roel; Vandenberghe, Stefaan; Vanhove, Christian

    2013-01-01

    C , R = −0.96) temperature changes. Count rate evaluation showed that although the total count rate is consistently higher at 21 °C than at 24 °C for different source activity concentrations, this is mainly due to an increase in scattered and random coincidences. The peak total count rate is 400 kcps at both temperatures but is reached at lower activity at 21 °C. The peak true count rate is 138 kcps (at 100 MBq) at 21 °C and 180 kcps (at 125 MBq) at 24 °C. The peak noise equivalent count rate is also lower at 21 °C (70 kcps at 70 MBq) than at 24 °C (100 kcps at 100 MBq). At realistic activity levels, the scatter fraction is lower at higher temperatures, but at the cost of a strong decrease in true count rate.Conclusions: A model was proposed for the temperature dependence of APD-based PET scanners and evaluated using the LabPET small animal PET scanner. System sensitivity and count rate performance are strongly dependent on ambient temperature while system resolution is not. The authors’ results indicate that it is important to assure stable ambient temperature to obtain reproducible results in imaging studies with APD-based PET scanners

  5. 'PET -Compton' system. Comparative evaluation with PET system using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Diaz Garcia, Angelina; Arista Romeu, Eduardo; Abreu Alfonso, Yamiel; Leyva Fabelo, Antonio; Pinnera Hernandez, Ibrahin; Bolannos Perez, Lourdes; Rubio Rodriguez, Juan A; Perez Morales, Jose M.; Arce Dubois, Pedro; Vela Morales, Oscar; Willmott Zappacosta, Carlos

    2011-01-01

    Positron Emission Tomography (PET) in small animals has actually achieved spatial resolution round about 1 mm and currently there are under study different approaches to improve this spatial resolution. One of them combines PET technology with Compton Cameras. This paper presents the idea of the so called 'PET-Compton' systems and includes comparative evaluation of spatial resolution and global efficiency in both PET and PET-Compton system by means of Monte Carlo simulations using Geant4 code. Simulation is done on a PET-Compton system consisting of LYSO-LuYAP scintillating detectors of particular small animal PET scanner named 'Clear-PET' and for Compton detectors based on CdZnTe semiconductor. A group of radionuclides that emits a positron (e + ) and γ quantum almost simultaneously and fulfills some selection criteria for their possible use in PET-Compton systems for medical and biological applications were studied under simulation conditions. (Author)

  6. PET-COMPTON System. Comparative evaluation with PET System using Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Diaz Garcia, Angelina; Arista Romeu, Eduardo; Abreu Alfonso, Yamiel; Leyva Fabelo, Antonio; Pinnera HernAndez, Ibrahin; Bolannos Perez, Lourdes; Rubio Rodriguez, Juan A.; Perez Morales, Jose M.; Arce Dubois, Pedro; Vela Morales, Oscar; Willmott Zappacosta, Carlos

    2012-01-01

    Positron Emission Tomography (PET) in small animals has actually achieved spatial resolution round about 1 mm and currently there are under study different approaches to improve this spatial resolution. One of them combines PET technology with Compton Cameras. This paper presents the idea of the so called PET-Compton systems and has included comparative evaluation of spatial resolution and global efficiency in both PET and PET-Compton system by means of Monte Carlo simulations using Geant4 code. Simulation was done on a PET-Compton system made-up of LYSO-LuYAP scintillating detectors of particular small animal PET scanner named Clear-PET and for Compton detectors based on CdZnTe semiconductor. A group of radionuclides that emits a positron (e+) and quantum almost simultaneously and fulfills some selection criteria for their possible use in PET-Compton systems for medical and biological applications were studied under simulation conditions. By means of analytical reconstruction using SSRB (Single Slide Rebinning) method were obtained superior spatial resolution in PET-Compton system for all tested radionuclides (reaching sub-millimeter values of for 22Na source). However this analysis done by simulation have shown limited global efficiency values in PET-Compton system (in the order of 10 -5 -10 -6 %) instead of values around 5*10 -1 % that have been achieved in PET system. (author)

  7. Pathology-based validation of FDG PET segmentation tools for volume assessment of lymph node metastases from head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schinagl, Dominic A.X. [Radboud University Nijmegen Medical Centre, Department of Radiation Oncology, Nijmegen (Netherlands); Radboud University Nijmegen Medical Centre, Department of Radiation Oncology (874), P.O. Box 9101, Nijmegen (Netherlands); Span, Paul N.; Kaanders, Johannes H.A.M. [Radboud University Nijmegen Medical Centre, Department of Radiation Oncology, Nijmegen (Netherlands); Hoogen, Frank J.A. van den [Radboud University Nijmegen Medical Centre, Department of Otorhinolaryngology, Head and Neck Surgery, Nijmegen (Netherlands); Merkx, Matthias A.W. [Radboud University Nijmegen Medical Centre, Department of Oral and Maxillofacial Surgery, Nijmegen (Netherlands); Slootweg, Piet J. [Radboud University Nijmegen Medical Centre, Department of Pathology, Nijmegen (Netherlands); Oyen, Wim J.G. [Radboud University Nijmegen Medical Centre, Department of Nuclear Medicine, Nijmegen (Netherlands)

    2013-12-15

    FDG PET is increasingly incorporated into radiation treatment planning of head and neck cancer. However, there are only limited data on the accuracy of radiotherapy target volume delineation by FDG PET. The purpose of this study was to validate FDG PET segmentation tools for volume assessment of lymph node metastases from head and neck cancer against the pathological method as the standard. Twelve patients with head and neck cancer and 28 metastatic lymph nodes eligible for therapeutic neck dissection underwent preoperative FDG PET/CT. The metastatic lymph nodes were delineated on CT (Node{sub CT}) and ten PET segmentation tools were used to assess FDG PET-based nodal volumes: interpreting FDG PET visually (PET{sub VIS}), applying an isocontour at a standardized uptake value (SUV) of 2.5 (PET{sub SUV}), two segmentation tools with a fixed threshold of 40 % and 50 %, and two adaptive threshold based methods. The latter four tools were applied with the primary tumour as reference and also with the lymph node itself as reference. Nodal volumes were compared with the true volume as determined by pathological examination. Both Node{sub CT} and PET{sub VIS} showed good correlations with the pathological volume. PET segmentation tools using the metastatic node as reference all performed well but not better than PET{sub VIS}. The tools using the primary tumour as reference correlated poorly with pathology. PET{sub SUV} was unsatisfactory in 35 % of the patients due to merging of the contours of adjacent nodes. FDG PET accurately estimates metastatic lymph node volume, but beyond the detection of lymph node metastases (staging), it has no added value over CT alone for the delineation of routine radiotherapy target volumes. If FDG PET is used in radiotherapy planning, treatment adaptation or response assessment, we recommend an automated segmentation method for purposes of reproducibility and interinstitutional comparison. (orig.)

  8. (90)Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction.

    Science.gov (United States)

    Carlier, Thomas; Willowson, Kathy P; Fourkal, Eugene; Bailey, Dale L; Doss, Mohan; Conti, Maurizio

    2015-07-01

    (90)Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with (90)Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging (90)Y and to compare experimental results with clinical data from two types of commercially available (90)Y microspheres. Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of (90)Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a (90)Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere(®) and 24 with SIR-Spheres(®)) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms

  9. 90Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

    International Nuclear Information System (INIS)

    Carlier, Thomas; Willowson, Kathy P.; Fourkal, Eugene; Bailey, Dale L.; Doss, Mohan; Conti, Maurizio

    2015-01-01

    Purpose: 90 Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with 90 Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging 90 Y and to compare experimental results with clinical data from two types of commercially available 90 Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of 90 Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a 90 Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere ® and 24 with SIR-Spheres ® ) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for

  10. Comparison of dosimetry between PET/CT and PET alone using 11C-ITMM

    International Nuclear Information System (INIS)

    Ito, Kimiteru; Sakata, Muneyuki; Wagarsuma, Kei; Toyohara, Jun; Ishibashi, Kenji; Ishii, Kenji; Ishiwata, Kiichi; Oda, Keiichi

    2016-01-01

    We used a new tracer, N-[4-[6-(isopropylamino) pyrimidin-4-yl]-1,3-thiazol-2-yl]-4- 11 C-methoxy-N-methylbenzamide ( 11 C-ITMM), to compare radiation doses from positron emission tomography (PET)/computed tomography (CT) with previously published doses from PET alone. Twelve healthy volunteers [six males (mean age ± SD, 27.7 ± 6.7 years) and six females (31.8 ± 14.5 years)] in 12 examinations were recruited. Dose estimations from PET/CT were compared with those from PET alone. Regions of interest (ROIs) in PET/CT were delineated on the basis of low-dose CT (LD-CT) images acquired during PET/CT. Internal and external radiation doses were estimated using OLINDA/EXM 1.0 and CT-Expo software. The effective dose (ED) for 11 C-ITMM calculated from PET/CT was estimated to be 4.7 ± 0.5 μSv/MBq for the male subjects and 4.1 ± 0.7 μSv/MBq for the female subjects. The mean ED for 11 C-ITMM calculated from PET alone in a previous report was estimated to be 4.6 ± 0.3 μSv/MBq (males, n = 3). The ED values for 11 C-ITMM calculated from PET/CT in the male subjects were almost identical to those from PET alone. The absorbed doses (ADs) of the gallbladder, stomach, red bone marrow, and spleen calculated from PET/CT were significantly different from those calculated from PET alone. The EDs of 11 C-ITMM calculated from PET/CT were almost identical to those calculated from PET alone. The ADs in several organs calculated from PET/CT differed from those from PET alone. LD-CT images acquired during PET/CT may facilitate organ identification.

  11. Detection and quantification of focal uptake in head and neck tumours: {sup 18}F-FDG PET/MR versus PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Varoquaux, Arthur; Rager, Olivier; Ratib, Osman; Becker, Christoph D.; Zaidi, Habib; Becker, Minerva [Geneva University Hospital, Department of Imaging, Divisions of Radiology and Nuclear Medicine, Geneva 14 (Switzerland); Poncet, Antoine [Geneva University Hospital, Center for Clinical Research, Geneva (Switzerland); Delattre, Benedicte M.A. [Geneva University Hospital, Department of Imaging, Divisions of Radiology and Nuclear Medicine, Geneva 14 (Switzerland); Philips Healthcare AG, Nuclear Medicine Division, Gland (Switzerland); Dulguerov, Pavel; Dulguerov, Nicolas [Geneva University Hospital, Clinic of Otorhinolaryngology Head and Neck Surgery, Geneva (Switzerland)

    2014-03-15

    Our objectives were to assess the quality of PET images and coregistered anatomic images obtained with PET/MR, to evaluate the detection of focal uptake and SUV, and to compare these findings with those of PET/CT in patients with head and neck tumours. The study group comprised 32 consecutive patients with malignant head and neck tumours who underwent whole-body {sup 18}F-FDG PET/MR and PET/CT. PET images were reconstructed using the attenuation correction sequence for PET/MR and CT for PET/CT. Two experienced observers evaluated the anonymized data. They evaluated image and fusion quality, lesion conspicuity, anatomic location, number and size of categorized (benign versus assumed malignant) lesions with focal uptake. Region of interest (ROI) analysis was performed to determine SUVs of lesions and organs for both modalities. Statistical analysis considered data clustering due to multiple lesions per patient. PET/MR coregistration and image fusion was feasible in all patients. The analysis included 66 malignant lesions (tumours, metastatic lymph nodes and distant metastases), 136 benign lesions and 470 organ ROIs. There was no statistically significant difference between PET/MR and PET/CT regarding rating scores for image quality, fusion quality, lesion conspicuity or anatomic location, number of detected lesions and number of patients with and without malignant lesions. A high correlation was observed for SUV{sub mean} and SUV{sub max} measured on PET/MR and PET/CT for malignant lesions, benign lesions and organs (ρ = 0.787 to 0.877, p < 0.001). SUV{sub mean} and SUV{sub max} measured on PET/MR were significantly lower than on PET/CT for malignant tumours, metastatic neck nodes, benign lesions, bone marrow, and liver (p < 0.05). The main factor affecting the difference between SUVs in malignant lesions was tumour size (p < 0.01). In patients with head and neck tumours, PET/MR showed equivalent performance to PET/CT in terms of qualitative results. Comparison of

  12. Participant Nonnaiveté and the reproducibility of cognitive psychology.

    Science.gov (United States)

    Zwaan, Rolf A; Pecher, Diane; Paolacci, Gabriele; Bouwmeester, Samantha; Verkoeijen, Peter; Dijkstra, Katinka; Zeelenberg, René

    2017-07-25

    Many argue that there is a reproducibility crisis in psychology. We investigated nine well-known effects from the cognitive psychology literature-three each from the domains of perception/action, memory, and language, respectively-and found that they are highly reproducible. Not only can they be reproduced in online environments, but they also can be reproduced with nonnaïve participants with no reduction of effect size. Apparently, some cognitive tasks are so constraining that they encapsulate behavior from external influences, such as testing situation and prior recent experience with the experiment to yield highly robust effects.

  13. PET diagnosis. The decisive factor for early detection of the cancer

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Kusakabe, Kiyoko; Fukuda, Hiroshi; Inoue, Kentaro; Tanaka, Koichi; Murayama, Hideo; Amano, Masaharu; Oikawa, Koichi; Yamashita, Takashi

    2007-01-01

    The feature contains 8 articles concerned with the subject matter in the title. The first is a document of the interview with Dr. Yoshiharu Yonekura, the National Institute of Radiological Sciences (NIRS) President, by the editor in chief of the journal, entitled ''Twenty to Thirty years are Necessary for Development of Basic Technology''- discussed are progress of molecular imaging, present and future of positron emission tomography (PET) diagnosis. Lasting are the articles of: ''Recommendation for PET diagnosis'' by K. Kusakabe, Tokyo Women's Medical Univ.- the role of PET diagnosis in a mass examination; ''The present state and future development of PET diagnosis of cancer'' by H. Fukuda and K. Inoue, Tohoku Univ. Hospital- labeled compounds and others; ''Promotion of popularization of the diagnosis as a part of CSR (corporate social responsibility) in the local medicare- A participation of the Hospital of Chugoku Electric Power Co., Ltd. in the project'' by K. Tanaka; ''Trend of development of next generation PET equipment'' by H. Murayama, NIRS- equipments like PET/CT or PET/MRI, and with high system sensitivity (detector- and photo-elements, DOI detection, high performance circuit, etc.); ''Achievement and developing trend of the equipments in the manufacturer- Shimadzu Corp.'' by M. Amano- PET/CT; ''(the same title)- Sumitomo Heavy Industries, Ltd.'' by K. Oikawa- cyclotron and therapeutic heavy ion beam generator; and ''Research and development in Hamamatsu Photonics K.K.'' by T. Yamashita- high throughput PET and animal PET. (R.T.)

  14. FDG-PET identification of intraperitoneal metastases

    International Nuclear Information System (INIS)

    Gamez, C.; Jimenez-Hoyuelam, J.M.; Rebollo, A.C.; Gonzalez, P.; Rico, J.M.; Alba, E.; Sacchetti, A.; Lopez-Rueda, B.

    2002-01-01

    Aim: Peritoneal metastases (PM) are usually from intra-abdominal primary neoplasms, such as carcinoma of the stomach, colon, ovary, and pancreas, or from intra-abdominal lymphoma. Metastases disseminate throughout the peritoneum in four ways: 1) direct spread along peritoneal ligaments, mesenteries and omenta; 2) via the flow of ascitis fluid. 3) lymphatic extension, and 4) embolic hematogenous spread. Although CT is quite specific in identifying PM it is not very sensitive, and peritoneal lavage or biopsy can be very useful but have sampling errors. This study assessed the clinical value of FDG-PET for the detection of PM of malignant diseases. Materials and Methods: 15 FDG-PET scans of patients referred for recurrence (mean age = 54 y/o, sex = 6M, 9F), with metabolic abnormalities suspicious findings of PM from carcinoma of the colon (7), ovary (3), lymphoma (2), pancreas (1), gastrointestinal stromal tumor (1) and melanoma (1) were reviewed. The whole-body studies were performed 50 min following the intravenous administration of 370 MBq of 18F-FDG, in a high resolution dedicated PET scanner (Advance, GEMS), with images reconstructed using a iterative algorithm with segmented attenuation correction. Visual interpretation and SUV values were correlated with CT/MRI findings and biopsy/follow-up. Results: Of the 15 patients, 7 showed <3 sites of focal uptake and 8 presented multiple foci or a diffuse hypermetabolism in the abdomen (SUVmax3.04-18.83 g/ml). 6 patients had biopsy confirmation by PET-directed surgery (6 proven PM, 0 negative biopsies). 11 FDG-PET scans had correspondence with the CT/MRI findings and 4 showed discrepancies (PET positive-CT/MRI negative in patients with isolated raising tumor markers levels or unsuspected PM). FDG-PET influenced the therapeutic management in 2 patients as presented multiple metastases leading them from surgery to chemotherapy. Conclusion: When used as a complementary imaging tool to the conventional work up, FDG-PET is

  15. The effects of segmentation algorithms on the measurement of 18F-FDG PET texture parameters in non-small cell lung cancer.

    Science.gov (United States)

    Bashir, Usman; Azad, Gurdip; Siddique, Muhammad Musib; Dhillon, Saana; Patel, Nikheel; Bassett, Paul; Landau, David; Goh, Vicky; Cook, Gary

    2017-12-01

    Measures of tumour heterogeneity derived from 18-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) scans are increasingly reported as potential biomarkers of non-small cell lung cancer (NSCLC) for classification and prognostication. Several segmentation algorithms have been used to delineate tumours, but their effects on the reproducibility and predictive and prognostic capability of derived parameters have not been evaluated. The purpose of our study was to retrospectively compare various segmentation algorithms in terms of inter-observer reproducibility and prognostic capability of texture parameters derived from non-small cell lung cancer (NSCLC) 18 F-FDG PET/CT images. Fifty three NSCLC patients (mean age 65.8 years; 31 males) underwent pre-chemoradiotherapy 18 F-FDG PET/CT scans. Three readers segmented tumours using freehand (FH), 40% of maximum intensity threshold (40P), and fuzzy locally adaptive Bayesian (FLAB) algorithms. Intraclass correlation coefficient (ICC) was used to measure the inter-observer variability of the texture features derived by the three segmentation algorithms. Univariate cox regression was used on 12 commonly reported texture features to predict overall survival (OS) for each segmentation algorithm. Model quality was compared across segmentation algorithms using Akaike information criterion (AIC). 40P was the most reproducible algorithm (median ICC 0.9; interquartile range [IQR] 0.85-0.92) compared with FLAB (median ICC 0.83; IQR 0.77-0.86) and FH (median ICC 0.77; IQR 0.7-0.85). On univariate cox regression analysis, 40P found 2 out of 12 variables, i.e. first-order entropy and grey-level co-occurence matrix (GLCM) entropy, to be significantly associated with OS; FH and FLAB found 1, i.e., first-order entropy. For each tested variable, survival models for all three segmentation algorithms were of similar quality, exhibiting comparable AIC values with overlapping 95% CIs. Compared with both

  16. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  17. Pet-Related Infections.

    Science.gov (United States)

    Day, Michael J

    2016-11-15

    Physicians and veterinarians have many opportunities to partner in promoting the well-being of people and their pets, especially by addressing zoonotic diseases that may be transmitted between a pet and a human family member. Common cutaneous pet-acquired zoonoses are dermatophytosis (ringworm) and sarcoptic mange (scabies), which are both readily treated. Toxoplasmosis can be acquired from exposure to cat feces, but appropriate hygienic measures can minimize the risk to pregnant women. Persons who work with animals are at increased risk of acquiring bartonellosis (e.g., cat-scratch disease); control of cat fleas is essential to minimize the risk of these infections. People and their pets share a range of tick-borne diseases, and exposure risk can be minimized with use of tick repellent, prompt tick removal, and appropriate tick control measures for pets. Pets such as reptiles, amphibians, and backyard poultry pose a risk of transmitting Salmonella species and are becoming more popular. Personal hygiene after interacting with these pets is crucial to prevent Salmonella infections. Leptospirosis is more often acquired from wildlife than infected dogs, but at-risk dogs can be protected with vaccination. The clinical history in the primary care office should routinely include questions about pets and occupational or other exposure to pet animals. Control and prevention of zoonoses are best achieved by enhancing communication between physicians and veterinarians to ensure patients know the risks of and how to prevent zoonoses in themselves, their pets, and other people.

  18. A small animal holding fixture system with positional reproducibility for longitudinal multimodal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kokuryo, Daisuke; Kimura, Yuichi; Obata, Takayuki; Yamaya, Taiga; Kawamura, Kazunori; Zhang, Ming-Rong; Kanno, Iwao; Aoki, Ichio, E-mail: ukimura@ieee.or [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan)

    2010-07-21

    This study presents a combined small animal holding fixture system, termed a 'bridge capsule', which provides for small animal re-fixation with positional reproducibility. This system comprises separate holding fixtures for the head and lower body and a connecting part to a gas anesthesia system. A mouse is fixed in place by the combination of a head fixture with a movable part made from polyacetal resin, a lower body fixture made from vinyl-silicone and a holder for the legs and tail. For re-fixation, a similar posture could be maintained by the same holding fixtures and a constant distance between the head and lower body fixtures is maintained. Artifacts caused by the bridge capsule system were not observed on magnetic resonance (MRI) and positron emission tomography (PET) images. The average position differences of the spinal column and the iliac body before and after re-fixation for the same modality were approximately 1.1 mm. The difference between the MRI and PET images was approximately 1.8 mm for the lower body fixture after image registration using fiducial markers. This system would be useful for longitudinal, repeated and multimodal imaging experiments requiring similar animal postures.

  19. PET and PET-CT. State of the art and future prospects

    International Nuclear Information System (INIS)

    Fanti, Stefano; Franchi, Roberto; Battista, Giuseppe; Monetti, Nino; Canini, Romeo

    2005-01-01

    Fluoro-deoxyglucose positron emission tomography (FDG PET) enables the in vivo study of tissue metabolism, and thus is able to identify malignant tumours as hypermetabolic lesions by an increase in tracer uptake. Many papers have demonstrated both the relevant impact of FDG PET on staging of many cancers and the superior accuracy of the technique compared with conventional diagnostic methods for pre-treatment evaluation, therapy response evaluation and relapse identification. In particular PET was found useful in identifying lymph nodal and metastatic spread. thus altering patient management in more than 30% of cases. PET images, however, provide limited anatomical data, which in regions such as the head and neck, mediastinum and pelvic cavity is a significant drawback. The exact localization of lesions may also be difficult in some cases, on the basis of PET images alone. The introduction of combined PET-computed tomography (PET-CT) scanners enables the almost simultaneous acquisition of transmission and emission images, thus obtaining optimal fusion images in a very short time. PET-CT fusion images enable lesions to be located, reducing false positive studies and increasing accuracy; the overall duration of examination may also be reduced. On the basis of both literature data and our experience we established the clinical indications when PET-CT may be particularly useful, in comparison with PET alone. It should also be underlined that the use of PET-CT is almost mandatory for new traces such as C-choline and C-methionine; these new tracers may be applied for studying tumours not assessable with FDG, such as prostate cancer. In conclusion PET-CT is at present the most advanced method for metabolic imaging, and is capable of precisely localizing and assessing tumours; fusion images reduce false positive and inconclusive studies, thus increasing diagnostic accuracy [it

  20. Ultimate waveform reproducibility of extreme-ultraviolet pulses by high-harmonic generation in quartz

    Science.gov (United States)

    Garg, M.; Kim, H. Y.; Goulielmakis, E.

    2018-05-01

    Optical waveforms of light reproducible with subcycle precision underlie applications of lasers in ultrafast spectroscopies, quantum control of matter and light-based signal processing. Nonlinear upconversion of optical pulses via high-harmonic generation in gas media extends these capabilities to the extreme ultraviolet (EUV). However, the waveform reproducibility of the generated EUV pulses in gases is inherently sensitive to intensity and phase fluctuations of the driving field. We used photoelectron interferometry to study the effects of intensity and carrier-envelope phase of an intense single-cycle optical pulse on the field waveform of EUV pulses generated in quartz nanofilms, and contrasted the results with those obtained in gas argon. The EUV waveforms generated in quartz were found to be virtually immune to the intensity and phase of the driving field, implying a non-recollisional character of the underlying emission mechanism. Waveform-sensitive photonic applications and precision measurements of fundamental processes in optics will benefit from these findings.

  1. {sup 18}F-DOPA PET/CT for assessment of response to induction chemotherapy in a child with high-risk neuroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Piccardo, Arnoldo [Galliera Hospital, Nuclear Medicine Unit, Genoa (Italy); E.O. Ospedali Galliera, Department of Nuclear Medicine, Genoa (Italy); Lopci, Egesta [Humanitas Clinical and Research Center, Nuclear Medicine Department, Rozzano, MI (Italy); Foppiani, Luca [Galliera Hospital, Internal Medicine and Endocrinology, Genoa (Italy); Morana, Giovanni [G. Gaslini Children' s Hospital, Department of Pathology and Radiology, Genoa (Italy); Conte, Massimo [G. Gaslini Children' s Hospital, Department of Hematology-Oncology, Genoa (Italy)

    2014-03-15

    Functional imaging plays a crucial role in the assessment of neuroblastoma. The evaluation of response to induction chemotherapy is a cornerstone in scheduling proper treatment management in patients affected by high-risk neuroblastoma. {sup 123}I-metaiodobenzylguanidine has been recognized as the radiopharmaceutical of choice in neuroblastoma assessment. To date, the clinical role of PET/CT in pediatric malignancy is not well established.{sup 18}F-DOPA-PET/CT has been recently used in neuroblastoma, and compared with {sup 123}I-MIBG-scan. Scant new data are available about the role of this tool in the evaluation of treatment response after induction chemotherapy. We investigate the role of {sup 18}F-DOPA-PET/CT in characterizing the response to induction chemotherapy in a child affected by high-risk-neuroblastoma, in whom the rare association of {sup 123}I-MIBG-negative primary tumor and MIBG-positive bone marrow metastases was observed. (orig.)

  2. Pet in Clinical oncology

    International Nuclear Information System (INIS)

    Hunsche, A.; Grossman, G.; Santana, M.; Santana, C.; Halkar, R.; Garcia, E.

    2003-01-01

    The utility of the PET (positron emission tomography in clinical oncology has been recognized for more than two decades, locating it as a sensible technique for the diagnosis and the prognosis stratification of the oncology patients. The sensitivity and specificity of the PET in comparation to other image studies have demonstrated to be greater. For some years, there was a restriction of PET because of the high cost of the equipment and the cyclotrons. Nevertheless, the relation of cost/benefits is considered as a priority as this technique offers important clinical information. In this article the results observed when using it in diverse types of cancer, as well as the effectiveness shown in the pre-operating evaluation, the evaluation of residual disease, diagnosis of recurrences, pursuit and prognosis stratification of the patients with cancer. (The author)

  3. Three dimensional positron-CT: 3D-PET

    International Nuclear Information System (INIS)

    Ishii, K.

    2000-01-01

    Positron-CT, namely the positron emission tomograph (PET) provides us the metabolism images obtained by the administration of the drug labeled by the positron emission nuclide in the human body. For example, the carbohydrate metabolism image is obtained by the administration of glucose labelled by 18 F-radioisotopes, and it can be applied to early detection of the cancer and research of high-order function of the brain. As well as X-ray CT, the examine receives the exposure in the positron CT. 3D-PET is based on the solid measurement of γ-rays, therefore, the detection sensitivity of 3D-PET becomes very high and it is possible to drastically reduce the dose of the positron emission nuclide. Because the exposure is reduced to the utmost, the positron CT diagnosis would be possible for the child and the exposure of positron CT doctor in charge can be also reduced. This ideal functional diagnostic imaging equipment, namely, 3D-PET is introduced here. (author)

  4. Reproducibility of ultrasonography for assessing abdominal fat distribution in a population at high risk of diabetes

    DEFF Research Database (Denmark)

    Philipsen, A; Carstensen, Bendix; Sandbæk, Annelli

    2013-01-01

    the reproducibility of this method have been published.Objective:The aim of this study was to investigate the reproducibility of ultrasonography in the assessment of abdominal fat distribution in a population at high risk of type 2 diabetes.Design and Methods:Ultrasonography was used to estimate visceral......- and interobserver variation, and Bland-Altman plots were drawn for all three substudies.Results:Coefficients of variation for intra- and interobserver variation were in the range 3.4-6.1%, except for interobserver variation for subcutaneous fat (9.5%). Short-term variation over a median of 35 days had a coefficient...

  5. Value of a dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions

    International Nuclear Information System (INIS)

    Eiber, Matthias; Holzapfel, Konstantin; Rummeny, Ernst J.; Martinez-Moeller, Axel; Souvatzoglou, Michael; Ziegler, Sibylle; Schwaiger, Markus; Nekolla, Stephan G.; Beer, Ambros J.; Pickhard, Anja; Loeffelbein, Dennys; Santi, Ivan

    2011-01-01

    In this study, the potential contribution of Dixon-based MR imaging with a rapid low-resolution breath-hold sequence, which is a technique used for MR-based attenuation correction (AC) for MR/positron emission tomography (PET), was evaluated for anatomical correlation of PET-positive lesions on a 3T clinical scanner compared to low-dose CT. This technique is also used in a recently installed fully integrated whole-body MR/PET system. Thirty-five patients routinely scheduled for oncological staging underwent 18 F-fluorodeoxyglucose (FDG) PET/CT and a 2-point Dixon 3-D volumetric interpolated breath-hold examination (VIBE) T1-weighted MR sequence on the same day. Two PET data sets reconstructed using attenuation maps from low-dose CT (PET AC C T ) or simulated MR-based segmentation (PET AC M R ) were evaluated for focal PET-positive lesions. The certainty for the correlation with anatomical structures was judged in the low-dose CT and Dixon-based MRI on a 4-point scale (0-3). In addition, the standardized uptake values (SUVs) for PET AC C T and PET AC M R were compared. Statistically, no significant difference could be found concerning anatomical localization for all 81 PET-positive lesions in low-dose CT compared to Dixon-based MR (mean 2.51 ± 0.85 and 2.37 ± 0.87, respectively; p = 0.1909). CT tended to be superior for small lymph nodes, bone metastases and pulmonary nodules, while Dixon-based MR proved advantageous for soft tissue pathologies like head/neck tumours and liver metastases. For the PET AC C T - and PET AC M R -based SUVs (mean 6.36 ± 4.47 and 6.31 ± 4.52, respectively) a nearly complete concordance with a highly significant correlation was found (r = 0.9975, p < 0.0001). Dixon-based MR imaging for MR AC allows for anatomical allocation of PET-positive lesions similar to low-dose CT in conventional PET/CT. Thus, this approach appears to be useful for future MR/PET for body regions not fully covered by diagnostic MRI due to potential time

  6. Quantification of atherosclerotic plaque activity and vascular inflammation using [18-F] fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT).

    Science.gov (United States)

    Mehta, Nehal N; Torigian, Drew A; Gelfand, Joel M; Saboury, Babak; Alavi, Abass

    2012-05-02

    Conventional non-invasive imaging modalities of atherosclerosis such as coronary artery calcium (CAC) and carotid intimal medial thickness (C-IMT) provide information about the burden of disease. However, despite multiple validation studies of CAC, and C-IMT, these modalities do not accurately assess plaque characteristics, and the composition and inflammatory state of the plaque determine its stability and, therefore, the risk of clinical events. [(18)F]-2-fluoro-2-deoxy-D-glucose (FDG) imaging using positron-emission tomography (PET)/computed tomography (CT) has been extensively studied in oncologic metabolism. Studies using animal models and immunohistochemistry in humans show that FDG-PET/CT is exquisitely sensitive for detecting macrophage activity, an important source of cellular inflammation in vessel walls. More recently, we and others have shown that FDG-PET/CT enables highly precise, novel measurements of inflammatory activity of activity of atherosclerotic plaques in large and medium-sized arteries. FDG-PET/CT studies have many advantages over other imaging modalities: 1) high contrast resolution; 2) quantification of plaque volume and metabolic activity allowing for multi-modal atherosclerotic plaque quantification; 3) dynamic, real-time, in vivo imaging; 4) minimal operator dependence. Finally, vascular inflammation detected by FDG-PET/CT has been shown to predict cardiovascular (CV) events independent of traditional risk factors and is also highly associated with overall burden of atherosclerosis. Plaque activity by FDG-PET/CT is modulated by known beneficial CV interventions such as short term (12 week) statin therapy as well as longer term therapeutic lifestyle changes (16 months). The current methodology for quantification of FDG uptake in atherosclerotic plaque involves measurement of the standardized uptake value (SUV) of an artery of interest and of the venous blood pool in order to calculate a target to background ratio (TBR), which is

  7. PET/MRI and PET/CT in advanced gynaecological tumours: initial experience and comparison

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Marcelo A.; Schulthess, Gustav von; Veit-Haibach, Patrick [University Hospital Zurich, Department Medical Radiology, Nuclear Medicine, Zurich (Switzerland); University Hospital Zurich, Department Medical Radiology, Diagnostic and Interventional Radiology, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); Kubik-Huch, Rahel A.; Freiwald-Chilla, Bianka [Kantonsspital Baden AG, Department of Radiology, Baden (Switzerland); Hauser, Nik [Kantonsspital Baden AG, Department of Gynaecology, Baden (Switzerland); Froehlich, Johannes M. [Guerbet AG, Zurich (Switzerland)

    2015-08-15

    To compare the diagnostic accuracy of PET/MRI and PET/CT for staging and re-staging advanced gynaecological cancer patients as well as identify the potential benefits of each method in such a population. Twenty-six patients with suspicious or proven advanced gynaecological cancer (12 ovarian, seven cervical, one vulvar and four endometrial tumours, one uterine metastasis, and one primary peritoneal cancer) underwent whole-body imaging with a sequential trimodality PET/CT/MR system. Images were analysed regarding primary tumour detection and delineation, loco-regional lymph node staging, and abdominal/extra-abdominal distant metastasis detection (last only by PET/CT). Eighteen (69.2 %) patients underwent PET/MRI for primary staging and eight patients (30.8 %) for re-staging their gynaecological malignancies. For primary tumour delineation, PET/MRI accuracy was statistically superior to PET/CT (p < 0.001). Among the different types of cancer, PET/MRI presented better tumour delineation mainly for cervical (6/7) and endometrial (2/3) cancers. PET/MRI for local evaluation as well as PET/CT for extra-abdominal metastases had therapeutic consequences in three and one patients, respectively. PET/CT detected 12 extra-abdominal distant metastases in 26 patients. PET/MRI is superior to PET/CT for primary tumour delineation. No differences were found in detection of regional lymph node involvement and abdominal metastases detection. (orig.)

  8. Comparative analysis of PET/CT and PET/MR image characteristics of head and neck squamous cell carcinoma%对比分析头颈部鳞状细胞癌PET/CT与PET/MR特征

    Institute of Scientific and Technical Information of China (English)

    白乐; 程勇; 唐勇进; 凌雪英

    2017-01-01

    Objective To investigate PET/CT and PET/MR characteristics of head and neck squamous cell carcinoma (HNSCC).Methods Totally 40 patients with HNSCC underwent whole body 18F-FDG PET/CT and MR scans of head and neck before anti-tumor treatment.PET positive lesions of HNSCC,including primary lesions and lymph nodes were evaluated by 2 radiologists independently.Then the imaging quality,fusion quality,lesion conspicuity and lesion characteristics were assessed based on PET/CT,PET/MR T1WI and PET/MR T2WI.Results Ninety PET positive lesions in all 40patients were evaluated,including 40 primary lesions and 50 lymph nodes.Similar imaging quality and fusion quality of PET/CT,PET/MR T1WI and PET/MR T2WI were obtained without statistical difference (both P>0.05).For the lesion conspicuity,PET/MR T1WI and PET/MR T2WI demonstrated significantly better than PET/CT in positive primary lesions and lymph nodes (all P<0.05).For the characteristics of positive primary lesions,PET/MR T2WI provided more information than PET/CT in 29 lesions,equal to PET/CT in 4 lesions,and less than PET/CT in 7 lesions.Conclusion The application of PET/MR in HNSCC is feasible,being superior to PET/CT in indication of lesions in head and neck area.%目的 探讨头颈部鳞状细胞癌(HNSCC)的PET/CT及PET/MR特征.方法 纳入未经抗肿瘤治疗的头颈部鳞状细胞癌患者40例,所有患者均接受PET/CT及头颈部MR检查.由2名观察者独立观察PET阳性病灶,包括阳性原发灶及阳性淋巴结;并对PET/CT、PET/MR T1WI及PET/MR T2WI的图像质量、融合准确度、病灶清晰度、病灶特征等进行评分.分析2名观察者间的一致性.结果 40例患者共90个PET阳性病灶,包括阳性原发灶40个、阳性淋巴结50个.PET/CT、PET/MR T1WI及PET/MR T2WI在图像质量及融合准确度方面差异均无统计学意义(P均>0.05);在显示阳性原发灶及阳性淋巴结的清晰度方面,PET/MR T1WI及PET/MR T2WI均优于PET/CT(P均<0.05).40个阳性原发灶中,PET

  9. 4-D PET-MR with Volumetric Navigators and Compressed Sensing

    DEFF Research Database (Denmark)

    Pedemonte, Stefano; Catana, Ciprian; Van Leemput, Koen

    2015-01-01

    Hybrid PET-MR scanners acquire multi-modal signals simultaneously, eliminating the requirement of software alignment between the MR and PET imaging data. However, the acquisition of high-resolution MR and PET images requires long scanning times, therefore movement of the subject during the acquis...

  10. Present and future of PET and PET/CT in gynaecologic malignancies

    International Nuclear Information System (INIS)

    Musto, Alessandra; Rampin, Lucia; Nanni, Cristina; Marzola, Maria Cristina; Fanti, Stefano; Rubello, Domenico

    2011-01-01

    Objectives: To review the published data in literature on patients affected by gynaecological malignancies to establish the role of 18 F-FDG positron emission tomography (PET) and PET/CT in comparison to conventional imaging (CI). Materials and methods: All papers specifically addressed to the role of 18 F-FDG PET and PET/CT in gynaecological malignancies published on PubMed/Medline, in abstracts from the principal international congresses, in the guidelines from national Societies that had appeared in literature until November 2009 were considered for the purpose of the present study. Results and conclusions: The use of 18 F-FDG PET, and even more of 18 F-FDG PET/CT, is increasing in the follow up of patients with gynaecologic malignancies and suspected recurrent disease: there is evidence in the literature that 18 F-FDG PET/CT has a higher sensitivity than CI in depicting occult metastatic spread. An interesting issue is represented by patients with ovarian cancer with an increase of the specific biomarker, CA-125, and negative/inconclusive findings at CI. The use of 18 F-FDG PET in differential diagnosis and staging is more controversial, but there is some evidence that a baseline PET examination performed before commencing therapy, for staging purpose, is also useful to evaluate the response to chemoradiation treatment. In several papers it has been suggested a relevant role of 18 F-FDG PET/CT in evaluating the entity of response to treatment and therefore to plan the subsequent therapeutic strategy.

  11. PET imaging in pediatric oncology

    International Nuclear Information System (INIS)

    Shulkin, B.L.

    2004-01-01

    High-quality PET imaging of pediatric patients is challenging and requires attention to issues commonly encountered in the practice of pediatric nuclear medicine, but uncommon to the imaging of adult patients. These include intravenous access, fasting, sedation, consent, and clearance of activity from the urinary tract. This paper discusses some technical differences involved in pediatric PET to enhance the quality of scans and assure the safety and comfort of pediatric patients. (orig.)

  12. [68Ga]Pentixafor-PET/MRI for the detection of Chemokine receptor 4 expression in atherosclerotic plaques

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiang; Heber, Daniel; Leike, Tatjana; Hacker, Marcus; Haug, Alexander R. [Medical University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Beitzke, Dietrich; Loewe, Christian [Medical University of Vienna, Division of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Lu, Xia; Zhang, Xiaoli; Wei, Yongxiang [Capital Medical University, Department of Nuclear Medicine, Beijing Anzhen Hospital, Beijing (China); Mitterhauser, Markus [Medical University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ludwig Boltzmann Institute Applied Diagnostics, Vienna (Austria); Wadsak, Wolfgang [Medical University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); CBmed, Center for Biomarker Research in Medicine, Graz (Austria); Kropf, Saskia [Scintomics GmbH, Fuerstenfeldbruck (Germany); Wester, Hans J. [Technische Universitaet Muenchen, Department of Radiopharmaceutical Chemistry, Garching (Germany)

    2018-04-15

    The expression of chemokine receptor type 4 (CXCR4) was found co-localized with macrophages on the atherosclerotic vessel wall and participated in the initial emigration of leukocytes. Gallium-68 [{sup 68}Ga]Pentixafor has recently been introduced for the imaging of atherosclerosis by targeting CXCR4. We sought to evaluate human atherosclerotic lesions using [{sup 68}Ga]Pentixafor PET/MRI. Thirty-eight oncology patients underwent [{sup 68}Ga]Pentixafor PET/MR imaging at baseline. Maximum standardized uptake values (SUV{sub max}) were derived from hot lesions in seven arterial segments and target-to-blood ratios (TBR) were calculated. ANOVA post-hoc and paired t test were performed for statistical comparison, Spearman's correlation coefficient between uptake ratios and cardiovascular risk factors were assessed. The reproducibility of [{sup 68}Ga]Pentixafor PET/MRI was assessed in seven patients with a follow-up examination by Pearson's regression and Bland-Altman plots analysis. Thirty-four of 38 patients showed 611 focal [{sup 68}Ga]Pentixafor uptake that followed the contours of the large arteries. Both prevalence and mean TBR{sub max} were highest in the descending aorta. There were significantly higher TBR values found in men (1.9 ± 0.3) as compared to women (1.7 ± 0.2; p < 0.05). Patients with mean TBR{sub max} > 1.7 showed a significantly higher incidence of diabetes, hypertension hypercholesterolemia and history of cardiovascular disease than patients with mean TBR{sub max} ≤ 1.7. [{sup 68}Ga]Pentixafor uptake showed a good reproducibility (r = 0.6, p < 0.01), and there was no difference between the mean TBR{sub max} values of plaque lesions (TBR{sub baseline}1.8 ± 0.3 vs TBR{sub follow-up}1.8 ± 0.3) (p = 0.9). Patients with high arterial uptake showed increased incidence of cardiovascular risk factors, suggesting a potential role of [{sup 68}Ga]Pentixafor in characterization of atherosclerosis. (orig.)

  13. High FDG uptake areas on pre-radiotherapy PET/CT identify preferential sites of local relapse after chemoradiotherapy for locally advanced oesophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Calais, Jeremie; Lemarignier, Charles; Vera, Pierre [Henri Becquerel Cancer Center and Rouen University Hospital, Nuclear Medicine Department, Rouen (France); University of Rouen, QuantIF-LITIS (Equipe d' Accueil 4108-FR CNRS 3638), Faculty of Medicine, Rouen (France); Dubray, Bernard [University of Rouen, QuantIF-LITIS (Equipe d' Accueil 4108-FR CNRS 3638), Faculty of Medicine, Rouen (France); Centre Henri Becquerel and Rouen University Hospital, Department of Radiotherapy and Medical Physics, Rouen (France); Nkhali, Lamyaa; Thureau, Sebastien; Modzelewski, Romain; Gardin, Isabelle [Henri Becquerel Cancer Center and Rouen University Hospital, Nuclear Medicine Department, Rouen (France); University of Rouen, QuantIF-LITIS (Equipe d' Accueil 4108-FR CNRS 3638), Faculty of Medicine, Rouen (France); Centre Henri Becquerel and Rouen University Hospital, Department of Radiotherapy and Medical Physics, Rouen (France); Di Fiore, Frederic [Rouen University Hospital, Department of Gastroenterology, Rouen (France); Rouen University Hospital, Department of Oncology, Henri Becquerel Cancer Center, IRON, Rouen (France); Michel, Pierre [Rouen University Hospital, Department of Gastroenterology, Rouen (France)

    2015-05-01

    The high failure rates in the radiotherapy (RT) target volume suggest that patients with locally advanced oesophageal cancer (LAOC) would benefit from increased total RT doses. High 2-deoxy-2-[{sup 18}F]fluoro-D-glucose (FDG) uptake (hotspot) on pre-RT FDG positron emission tomography (PET)/CT has been reported to identify intra-tumour sites at increased risk of relapse after RT in non-small cell lung cancer and in rectal cancer. Our aim was to confirm these observations in patients with LAOC and to determine the optimal maximum standardized uptake value (SUV{sub max}) threshold to delineate smaller RT target volumes that would facilitate RT dose escalation without impaired tolerance. The study included 98 consecutive patients with LAOC treated by chemoradiotherapy (CRT). All patients underwent FDG PET/CT at initial staging and during systematic follow-up in a single institution. FDG PET/CT acquisitions were coregistered on the initial CT scan. Various subvolumes within the initial tumour (30, 40, 50, 60, 70, 80 and 90 % SUV{sub max} thresholds) and in the subsequent local recurrence (LR, 40 and 90 % SUV{sub max} thresholds) were pasted on the initial CT scan and compared[Dice, Jaccard, overlap fraction (OF), common volume/baseline volume, common volume/recurrent volume]. Thirty-five patients had LR. The initial metabolic tumour volume was significantly higher in LR tumours than in the locally controlled tumours (mean 25.4 vs 14.2 cc; p = 0.002). The subvolumes delineated on initial PET/CT with a 30-60 % SUV{sub max} threshold were in good agreement with the recurrent volume at 40 % SUV{sub max} (OF = 0.60-0.80). The subvolumes delineated on initial PET/CT with a 30-60 % SUV{sub max} threshold were in good to excellent agreement with the core volume (90 % SUV{sub max}) of the relapse (common volume/recurrent volume and OF indices 0.61-0.89). High FDG uptake on pretreatment PET/CT identifies tumour subvolumes that are at greater risk of recurrence after CRT in

  14. Molecular imaging of neuroendocrine tumors using 68Ga-labeled peptides (Somatostatin receptor PET/CT)

    International Nuclear Information System (INIS)

    Baum, R.P.; Prasad, V.; Hoersch, D.

    2009-01-01

    Receptor PET/CT using 68 Ga-labeled somatostatin analogues (DOTA-NOC, DOTA-TOC or DOTA-TATE) enables the highly sensitive molecular imaging of neuroendocrine tumors (NETs) based on the expression of somatostatin receptors and even the detection of receptor subtypes. Our experience after more than 3000 studies shows that receptor PET/CT has a significantly higher tumor detection rate than conventional scintigraphy (even in SPECT/CT technique), and that tumor lesions can be very accurately localized. By calculating standardized uptake values (SUV) - which are reproducible and investigator-independent - patients can be selected for peptide receptor radiotherapy and also the course after therapy can be controlled. Receptor-PET/CT is the most sensitive imaging modality for the detection of unknown primary tumors (CUP syndrome), which is especially true for the detection of neuroendocrine tumors of the pancreas and small bowel; whole-body staging (''one stop shop'') as well as restaging and selection of patients for peptide receptor radiotherapy can be performed using a patient-friendly procedure (examination finished within one hour) exposing the patient to less radiation than whole-body CT scanning. The 68 Ge/ 68 Ga generator has proved very reliable over the years - even in a hospital environment. The effective costs for 68 Ga labeled somatostatin analogues might be less than for scintigraphic agents, provided a certain number of studies per year are performed. The development of new tumor-specific peptides as well as of other DOTA- or NOTA-coupled radiopharmaceuticals opens a new avenue into the future: finally, the 68 Ga generator could play a similar important role for PET/CT as did the 99m Tc-Generator for conventional gamma camera imaging over the last decades. (orig.)

  15. The journey: from X-rays to PET-MRI

    International Nuclear Information System (INIS)

    Sheikh, Tariq Hussain

    2010-01-01

    Full text: Medical imaging has undergone remarkable evolution over the past century. Since the discovery of the X-rays by (Wilhelm Conrad Roentgen), static emission tomography (Hal Anger) computed tomography (Godfrey Hounsfield and Alan Cormack), and magnetic resonance imaging (Paul Lauterbur and Peter Mansfield) there have been many other important discoveries and technical developments that have culminated in our current sophisticated multi-modality imaging systems. Nobel Prizes have been given for the discoveries of radioactivity (Marie Curie, Pierre Curie, and Henri Becquerel in 1903) and the positron (Carl Anderson in 1936) and for technical developments such as the radiotracer concept (George De Hevesy in 1943). Positron emission detection systems have developed since their first use in the 1950s to the high-resolution, high-sensitivity tomographic devices that we have today. In keeping pace with these milestones in the evolution of medical imaging, positron emission tomography (PET), and more recently integrated positron emission tomography-computed tomography (PET-CT), have now emerged not only as important research tools but also as significant diagnostic imaging systems in clinical medicine. The use of multi-modality imaging systems and 'smart' specific imaging agents will achieve the key task of accurate diagnosis, treatment evaluation, surveillance, and prognosis in individual patients. PET-CT instrumentation has continued to evolve rapidly, especially over the last decade A PET scanner is combined with a CT scanner into a single machine. The PET and CT components are mounted on the same aluminium support with the CT on the front and PET at the back. Metabolic information is obtained from the PET scanner (emission of annihilation photons) and anatomic information is obtained from the CT scan (transmission of X-Rays). In addition, the CT scan can be used to provide information needed for attenuation correction. The current generation of PET-CT scanners

  16. Survey to investigate pet ownership and attitudes to pet care in metropolitan Chicago dog and/or cat owners.

    Science.gov (United States)

    Freiwald, Amber; Litster, Annette; Weng, Hsin-Yi

    2014-08-01

    The aims of this descriptive cross-sectional study were to investigate dog and cat acquisition and attitudes toward pet care among residents of the Chicago area (zip codes 60600-60660); to compare data obtained from owners of shelter-acquired pets with those of residents who acquired their pets from other sources; to compare data from dog owners with cat owners; and to compare pet health practices among the respondents of different zip code income groups. In-person surveys administered at five pet store locations collected data from 529 respondents, representing 582 dogs and 402 cats owned or continuously cared for in the past 3 years. Median household income data for represented zip codes was also obtained. Shelters were the most common source of cats (ppet stores, breeders or rescue organizations and to be kept as outdoor-only pets (pPet owners were most commonly 'very likely' (5 on a 1-5/5 Likert scale) to administer all hypothetical treatments discussed, although cat owners were less likely to spend time training their pet (p=0.05). Cat owners were less likely to have taken their pet to a veterinarian for vaccinations or annual physical exams (ppets were at least as willing as other respondents to administer hypothetical treatments and pay ≥$1000 for veterinary treatment. Respondents from site #3 lived in zip codes that had relatively lower median household incomes (ppets than those at the four other sites (ppet owners from all acquisition categories expressed very high levels of attachment (≥8-10/10 on a Likert scale), except for owners of cats acquired as strays (84.9%) or from the 'other' category (75.0%). Survey respondents commonly acquired their pets from shelters and those who did were at least as willing to pay for and provide veterinary care as respondents who owned pets acquired from other sources. The data collected provides a snapshot of the attitudes of survey respondents in the Chicago area toward pet acquisition and care. Copyright © 2014

  17. High Reproducibility of ELISPOT Counts from Nine Different Laboratories

    DEFF Research Database (Denmark)

    Sundararaman, Srividya; Karulin, Alexey Y; Ansari, Tameem

    2015-01-01

    The primary goal of immune monitoring with ELISPOT is to measure the number of T cells, specific for any antigen, accurately and reproducibly between different laboratories. In ELISPOT assays, antigen-specific T cells secrete cytokines, forming spots of different sizes on a membrane with variable...

  18. Clinical Application of 18F-FDG PET in Alzheimer's Disease

    International Nuclear Information System (INIS)

    Ryu, Young Hoon

    2008-01-01

    PET of the cerebral metabolic rate of glucose is increasingly used to support the clinical diagnosis in the examination of patients with suspected major neurodegenerative disorders, such as Alzheimer's disease. 18 F-FDG PET has been reported to have high diagnostic performance, especially, very high sensitivity in the diagnosis and clinical assessment of therapeutic efficacy. According to clinical research data hitherto, 18 F-FDG PET is expected to be an effective diagnostic tool in early and differential diagnosis of Alzheimer's disease. Since 2004, Medicare covers 18 F-FDG PET scans for the differential diagnosis of fronto-temporal dementia (FTD) and Alzheimer's disease (AD) under specific requirements; or, its use in a CMS approved practical clinical trial focused on the utility of 18 F-FDG PET in the diagnosis or treatment of dementing neurodegenerative diseases

  19. Assessment of various strategies for 18F-FET PET-guided delineation of target volumes in high-grade glioma patients.

    Science.gov (United States)

    Vees, Hansjörg; Senthamizhchelvan, Srinivasan; Miralbell, Raymond; Weber, Damien C; Ratib, Osman; Zaidi, Habib

    2009-02-01

    The purpose of the study is to assess the contribution of (18)F-fluoro-ethyl-tyrosine ((18)F-FET) positron emission tomography (PET) in the delineation of gross tumor volume (GTV) in patients with high-grade gliomas compared with magnetic resonance imaging (MRI) alone. The study population consisted of 18 patients with high-grade gliomas. Seven image segmentation techniques were used to delineate (18)F-FET PET GTVs, and the results were compared to the manual MRI-derived GTV (GTV(MRI)). PET image segmentation techniques included manual delineation of contours (GTV(man)), a 2.5 standardized uptake value (SUV) cutoff (GTV(2.5)), a fixed threshold of 40% and 50% of the maximum signal intensity (GTV(40%) and GTV(50%)), signal-to-background ratio (SBR)-based adaptive thresholding (GTV(SBR)), gradient find (GTV(GF)), and region growing (GTV(RG)). Overlap analysis was also conducted to assess geographic mismatch between the GTVs delineated using the different techniques. Contours defined using GTV(2.5) failed to provide successful delineation technically in three patients (18% of cases) as SUV(max) segmentation algorithm is crucial, since it impacts both the volume and shape of the resulting GTV. The 2.5 SUV isocontour and GF segmentation techniques performed poorly and should not be used for GTV delineation. With adequate setting, the SBR-based PET technique may add considerably to conventional MRI-guided GTV delineation.

  20. Imaging performance of a full-ring prototype PET-MRI system based on four-layer DOI-PET detectors integrated with a RF coil

    Energy Technology Data Exchange (ETDEWEB)

    Nishikido, Fumihiko; Tashima, Hideaki [National Institute of Radiological Sciences, Chiba (Japan); Suga, Mikio [Chiba University, Chiba (Japan); Inadama, Naoko; Eiji, Yoshida; Obata, Takayuki; Yamaya, Taiga [National Institute of Radiological Sciences, Chiba (Japan)

    2015-05-18

    We are developing a PET system integrated with a birdcage RF-coil for PET-MRI in order to realize both high sensitivity and high spatial resolution of the PET image by using the 4-layered depth-of-interaction (DOI) PET detector. We constructed a full-ring prototype system and evaluated performances, especially imaging performance, of the prototype system in simultaneous measurement. The prototype system consists of eight four-layer DOI-PET detectors and a prototype birdcage RF-coil developed for the proposed system. The PET detectors consist of six monolithic multi-pixel photon counter array (S11064-050P), a readout circuit, fourlayer DOI scintillator arrays and a shielding box made of 35 μm thick copper foil. The crystal array consists of 2.0 mm x 2.0 mm x 5.0 mm LYSO crystals arranged in 38 x 6 x 4 layer. The RF-coil has eight coil elements and the eight PET detectors are positioned at each element gap. The diameter of the RF-coil elements is 261 mm. We conducted performance tests of the prototype system with a 3.0 T MRI (MAGNETOM Verio). Only the PET detectors, the RF-coil and the cables were in an MRI room during measurements. A data acquisition system and power supplies for the MPPCs and preamplifiers were outside the MRI room and connected to all the detectors through a penetration panel. As a result, the spatial resolutions of a Na-22 point source in the PET image were lower than 1.6 mm in whole the FOV due to the DOI capability. In addition, the influence of the simultaneous measurements on the PET performance is negligible. On the other hand, the SNR of the phantom image in the magnitude images was degraded from 259.7 to 209.4 due to noise contamination from the power supplies.

  1. Imaging performance of a full-ring prototype PET-MRI system based on four-layer DOI-PET detectors integrated with a RF coil

    International Nuclear Information System (INIS)

    Nishikido, Fumihiko; Tashima, Hideaki; Suga, Mikio; Inadama, Naoko; Eiji, Yoshida; Obata, Takayuki; Yamaya, Taiga

    2015-01-01

    We are developing a PET system integrated with a birdcage RF-coil for PET-MRI in order to realize both high sensitivity and high spatial resolution of the PET image by using the 4-layered depth-of-interaction (DOI) PET detector. We constructed a full-ring prototype system and evaluated performances, especially imaging performance, of the prototype system in simultaneous measurement. The prototype system consists of eight four-layer DOI-PET detectors and a prototype birdcage RF-coil developed for the proposed system. The PET detectors consist of six monolithic multi-pixel photon counter array (S11064-050P), a readout circuit, fourlayer DOI scintillator arrays and a shielding box made of 35 μm thick copper foil. The crystal array consists of 2.0 mm x 2.0 mm x 5.0 mm LYSO crystals arranged in 38 x 6 x 4 layer. The RF-coil has eight coil elements and the eight PET detectors are positioned at each element gap. The diameter of the RF-coil elements is 261 mm. We conducted performance tests of the prototype system with a 3.0 T MRI (MAGNETOM Verio). Only the PET detectors, the RF-coil and the cables were in an MRI room during measurements. A data acquisition system and power supplies for the MPPCs and preamplifiers were outside the MRI room and connected to all the detectors through a penetration panel. As a result, the spatial resolutions of a Na-22 point source in the PET image were lower than 1.6 mm in whole the FOV due to the DOI capability. In addition, the influence of the simultaneous measurements on the PET performance is negligible. On the other hand, the SNR of the phantom image in the magnitude images was degraded from 259.7 to 209.4 due to noise contamination from the power supplies.

  2. The impact of PET-CT in suspected recurrent ovarian cancer: A prospective multi-centre study as part of the Australian PET Data Collection Project.

    Science.gov (United States)

    Fulham, M J; Carter, J; Baldey, A; Hicks, R J; Ramshaw, J E; Gibson, M

    2009-03-01

    To assess the impact of FDG PET-CT on the management of patients with suspected recurrent ovarian cancer and to determine the incremental information provided by PET-CT. This was a prospective, multi-centre, cohort study. Ninety women (mean age 59.9 years; age range 35-85 years) with a previous history of treated epithelial ovarian carcinoma and suspected recurrence based on elevated CA-125, anatomical imaging or clinical symptoms were studied with FDG PET-CT across two States. Referring doctors were asked to specify a management plan pre-PET, if management was altered after PET-CT and, the impact (rated - none, low, medium, high) of PET-CT on patient management. The pre-PET management plan could include radiotherapy, chemotherapy, surgery, and 'other' including observation. Patients were followed at 6 and 12 months and clinical status, evidence of recurrence and progression were recorded. Patients were referred by 34 individual specialists. At least 168 additional sites of disease in 61 patients (68%), not identified by conventional imaging were identified by PET-CT. In 77% the additional lesions were located below the diaphragm and most were nodal or peritoneal. PET-CT affected management in 60% (49% high, 11% medium impact). Patients where more disease was detected with PET-CT were more likely to progress in the following 12 months. For women with previously treated ovarian carcinoma with recurrent disease, PET-CT can: a) alter management in close to 60% of patients, b) detect more sites of disease than abdominal and pelvic CT, c) is superior in the detection of nodal, peritoneal and subcapsular liver disease and d) offers the opportunity for technology replacement in this setting.

  3. Evaluation of suspected local recurrence in head and neck cancer: A comparison between PET and PET/CT for biopsy proven lesions

    International Nuclear Information System (INIS)

    Halpern, Benjamin S.; Yeom, Kristen; Fueger, Barbara J.; Lufkin, Robert B.; Czernin, Johannes; Allen-Auerbach, Martin

    2007-01-01

    Background: 18 F-FDG PET has a high accuracy for re-staging of head and neck cancer. The purpose of this study was to determine whether the diagnostic accuracy can be further improved with integrated PET/CT. Materials and methods: Forty-nine patients with a mean age of 59 ± 18 years were studied retrospectively. Histo-pathological verification was available either from complete tumor resection with or without lymph node dissection (n = 27) or direct endoscopic biopsy (n = 16) or ultrasound guided biopsy (n = 6). Two reviewers blinded to the pathological findings read all PET images in consensus. An experienced radiologist was added for the interpretation of the PET/CT images. Results: Tissue verification was available for 110 lesions in 49 patients. Sixty-seven lesions (61%) were biopsy positive and 43 (39%) were negative for malignant disease. PET and PET/CT showed an overall accuracy for cancer detection of 84 and 88% (p = 0.06), respectively. Sensitivity and specificity for PET were 78 and 93% versus 84 (p = NS) and 95% (p = NS) with PET/CT. A patient-by-patient analysis yielded a sensitivity, specificity and accuracy for PET of 80, 56 and 76%, compared to 88% (p = NS), 78% (p = NS) and 86% (p = 0.06) for PET/CT. Conclusion: The results of this study indicate that PET/CT does not significantly improve the detection of recurrence of head and neck cancer. However, a trend towards improved accuracy was observed (p = 0.06)

  4. Highly stable acyclic bifunctional chelator for {sup 64}Cu PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Abada, S.; Lecointre, A.; Christine, C.; Charbonniere, L. [CNRS/UDS, EPCM, Strasbourg (France). Lab. d' Ingenierie Appliquee a l' Analyse; Dechamps-Olivier, I. [Univ. de Reims Champagne Ardenne, Reims (France). Group Chimie de Coordination; Platas-Iglesias, C. [Univ. da Coruna (Spain). Dept. de Quimica Fundamental; Elhabiri, M. [CNRS/UDS, EPCM, Strasbourg (France). Lab. de Physico-Chimie Bioinorganique

    2011-07-01

    Ligand L{sup 1}, based on a pyridine scaffold, functionalized by two bis(methane phosphonate)aminomethyl groups, was shown to display a very high affinity towards Cu(II) (log K{sub CuL}=22.7) and selectivity over Ni(II), Co(II), Zn(II) and Ga(III) ({delta} log K{sub ML}>4) as shown by the values of the stability constants obtained from potentiometric measurements. Insights into the coordination mode of the ligand around Cu(II) cation were obtained by UV-Vis absorption and EPR spectroscopies as well as density functional theory (DFT) calculations (B3LYP model) performed in aqueous solution. The results point to a pentacoordination pattern of the metal ion in the fully deprotonated [CuL{sup 1}]{sup 6-} species. Considering the beneficial thermodynamic parameters of this ligand, kinetic experiments were run to follow the formation of the copper(II) complexes, indicating a very rapid formation of the complex, appropriate for {sup 64}Cu complexation. As L{sup 1} represents a particularly interesting target within the frame of {sup 64}Cu PET imaging, a synthetic protocol was developed to introduce a labeling function on the pyridyl moiety of L{sup 1}, thereby affording L{sup 2}, a potential bifunctional chelator (BFC) for PET imaging.

  5. Standardised uptake values from PET/CT images: comparison with conventional attenuation-corrected PET

    International Nuclear Information System (INIS)

    Souvatzoglou, M.; Ziegler, S.I.; Martinez, M.J.; Dzewas, G.; Schwaiger, M.; Bengel, F.; Busch, R.

    2007-01-01

    In PET/CT, CT-derived attenuation factors may influence standardised uptake values (SUVs) in tumour lesions and organs when compared with stand-alone PET. Therefore, we compared PET/CT-derived SUVs intra-individually in various organs and tumour lesions with stand-alone PET-derived SUVs. Thirty-five patients with known or suspected cancer were prospectively included. Sixteen patients underwent FDG PET using an ECAT HR+scanner, and subsequently a second scan using a Biograph Sensation 16PET/CT scanner. Nineteen patients were scanned in the reverse order. All images were reconstructed with an iterative algorithm (OSEM). Suspected lesions were grouped as paradiaphragmatic versus distant from the diaphragm. Mean and maximum SUVs were also calculated for brain, lung, liver, spleen and vertebral bone. The attenuation coefficients (μ values) used for correction of emission data (bone, soft tissue, lung) in the two data sets were determined. A body phantom containing six hot spheres and one cold cylinder was measured using the same protocol as in patients. Forty-six lesions were identified. There was a significant correlation of maximum and mean SUVs derived from PET and PET/CT for 14 paradiaphragmatic lesions (r=0.97 respectively; p<0.001 respectively) and for 32 lesions located distant from the diaphragm (r=0.87 and r=0.89 respectively; p<0.001 respectively). No significant differences were observed in the SUVs calculated with PET and PET/CT in the lesions or in the organs. In the phantom, radioactivity concentration in spheres calculated from PET and from PET/CT correlated significantly (r=0.99; p<0.001). SUVs of cancer lesions and normal organs were comparable between PET and PET/CT, supporting the usefulness of PET/CT-derived SUVs for quantification of tumour metabolism. (orig.)

  6. Present and future of PET and PET/CT in gynaecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Musto, Alessandra [Department of Nuclear Medicine, PET Center, Policlinico Sant' Orsola Malpighi, Bologna University, Bologna (Italy); Rampin, Lucia [Department of Nuclear Medicine, PET Center, Radiology, Medical Physics, Santa Maria della Misericordia Hospital, viale tre martiri 140, 45100 Rovigo (Italy); Nanni, Cristina [Department of Nuclear Medicine, PET Center, Policlinico Sant' Orsola Malpighi, Bologna University, Bologna (Italy); Marzola, Maria Cristina [Department of Nuclear Medicine, PET Center, Radiology, Medical Physics, Santa Maria della Misericordia Hospital, viale tre martiri 140, 45100 Rovigo (Italy); Fanti, Stefano [Department of Nuclear Medicine, PET Center, Policlinico Sant' Orsola Malpighi, Bologna University, Bologna (Italy); Rubello, Domenico, E-mail: domenico.rubello@libero.it [Department of Nuclear Medicine, PET Center, Radiology, Medical Physics, Santa Maria della Misericordia Hospital, viale tre martiri 140, 45100 Rovigo (Italy)

    2011-04-15

    Objectives: To review the published data in literature on patients affected by gynaecological malignancies to establish the role of {sup 18}F-FDG positron emission tomography (PET) and PET/CT in comparison to conventional imaging (CI). Materials and methods: All papers specifically addressed to the role of {sup 18}F-FDG PET and PET/CT in gynaecological malignancies published on PubMed/Medline, in abstracts from the principal international congresses, in the guidelines from national Societies that had appeared in literature until November 2009 were considered for the purpose of the present study. Results and conclusions: The use of {sup 18}F-FDG PET, and even more of {sup 18}F-FDG PET/CT, is increasing in the follow up of patients with gynaecologic malignancies and suspected recurrent disease: there is evidence in the literature that {sup 18}F-FDG PET/CT has a higher sensitivity than CI in depicting occult metastatic spread. An interesting issue is represented by patients with ovarian cancer with an increase of the specific biomarker, CA-125, and negative/inconclusive findings at CI. The use of {sup 18}F-FDG PET in differential diagnosis and staging is more controversial, but there is some evidence that a baseline PET examination performed before commencing therapy, for staging purpose, is also useful to evaluate the response to chemoradiation treatment. In several papers it has been suggested a relevant role of {sup 18}F-FDG PET/CT in evaluating the entity of response to treatment and therefore to plan the subsequent therapeutic strategy.

  7. PET/CT与PET/MR在诊断宫颈癌原发灶及评价盆腔淋巴结转移的比较研究%Value of PET/CT and PET/MR in diagnosing primary cervical cancer and evaluating pelvic lymph node metastasis: Comparative study

    Institute of Scientific and Technical Information of China (English)

    尚靳; 孙洪赞; 辛军; 郭启勇

    2018-01-01

    had no significant difference (Z=0.83,P>0.05).No significant differences in lesion visibility between PET/CT and PET/MR images were detected in the evaluation of metastatic lymph nodes (P=0.157),while PET/MR revealed higher values regarding diagnostic confidence (P=0.014).Conclusion Both PET/CT and PET/MR provide high diagnostic value in detecting primary cervical cancer,but PET/MR has greater diagnostic superiority in the correct identification of cervical cancer stage and pelvic lymph node metastasis.PET/MR is expected to be a new technique for replacement of PET/CT in evaluation of cervical lesions.

  8. Fully automated synthesis of ¹¹C-acetate as tumor PET tracer by simple modified solid-phase extraction purification.

    Science.gov (United States)

    Tang, Xiaolan; Tang, Ganghua; Nie, Dahong

    2013-12-01

    Automated synthesis of (11)C-acetate ((11)C-AC) as the most commonly used radioactive fatty acid tracer is performed by a simple, rapid, and modified solid-phase extraction (SPE) purification. Automated synthesis of (11)C-AC was implemented by carboxylation reaction of MeMgBr on a polyethylene Teflon loop ring with (11)C-CO2, followed by acidic hydrolysis with acid and SCX cartridge, and purification on SCX, AG11A8 and C18 SPE cartridges using a commercially available (11)C-tracer synthesizer. Quality control test and animals positron emission tomography (PET) imaging were also carried out. A high and reproducible decay-uncorrected radiochemical yield of (41.0 ± 4.6)% (n=10) was obtained from (11)C-CO2 within the whole synthesis time about 8 min. The radiochemical purity of (11)C-AC was over 95% by high-performance liquid chromatography (HPLC) analysis. Quality control test and PET imaging showed that (11)C-AC injection produced by the simple SPE procedure was safe and efficient, and was in agreement with the current Chinese radiopharmaceutical quality control guidelines. The novel, simple, and rapid method is readily adapted to the fully automated synthesis of (11)C-AC on several existing commercial synthesis module. The method can be used routinely to produce (11)C-AC for preclinical and clinical studies with PET imaging. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Clinical Application of 18F-FDG PET in Ovarian Cancer

    International Nuclear Information System (INIS)

    Oh, So Won; Kim, Seok Ki

    2008-01-01

    Ovarian cancer is often fatal since it is difficult to diagnose early and recurrence is quite frequent despite successful implementation of cytoreductive surgery and chemotherapy, thus exact diagnosis and early detection of recurrence are crucial to patient management. For pre-treatment staging, FDG PET could be helpful in a limited patient group possessing high risks of ovarian cancer. Besides, FDG PET could be recommended to patients with a high suspicion of recurrence i.e. rise of CA-125, especially in cases of conventional diagnostic imaging modalities presenting no evidence of disease because FDG PET provides critical information for treatment planning such as recurrence site or pattern. In order to expand the use of FDG PET to general population at staging or routine surveillance of ovarian cancer, more investigation is needed. The usefulness of FDG PET in evaluating treatment response and prognosis of ovarian cancer has not yet been determined, but it has been reported that FDG PET could evaluate treatment response early and show a close relationship with overall survival. PET/CT has been actively adopted in management of ovarian cancer. Not only in detecting tumor recurrence and evaluating treatment response but also in pre-treatment staging, FDG PET/CT is expected to play a role due to available anatomical information

  10. Magnetic Resonance-based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging.

    Science.gov (United States)

    Rakvongthai, Yothin; El Fakhri, Georges

    2017-07-01

    Motion degrades image quality and quantitation of PET images, and is an obstacle to quantitative PET imaging. Simultaneous PET-MR offers a tool that can be used for correcting the motion in PET images by using anatomic information from MR imaging acquired concurrently. Motion correction can be performed by transforming a set of reconstructed PET images into the same frame or by incorporating the transformation into the system model and reconstructing the motion-corrected image. Several phantom and patient studies have validated that MR-based motion correction strategies have great promise for quantitative PET imaging in simultaneous PET-MR. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Repeatability of quantitative parameters of 18F-fluoride PET/CT and biochemical tumour and specific bone remodelling markers in prostate cancer bone metastases.

    Science.gov (United States)

    Wassberg, Cecilia; Lubberink, Mark; Sörensen, Jens; Johansson, Silvia

    2017-12-01

    18F-fluoride PET/CT exhibits high sensitivity to delineate and measure the extent of bone metastatic disease in patients with prostate cancer. 18F-fluoride PET/CT could potentially replace traditional bone scintigraphy in clinical routine and trials. However, more studies are needed to assess repeatability and biological uptake variation. The aim of this study was to perform test-retest analysis of quantitative PET-derived parameters and blood/serum bone turnover markers at the same time point. Ten patients with prostate cancer and verified bone metastases were prospectively included. All underwent two serial 18F-fluoride PET/CT at 1 h post-injection. Up to five dominant index lesions and whole-body 18F-fluoride skeletal tumour burden were recorded per patient. Lesion-based PET parameters were SUVmax, SUVmean and functional tumour volume applying a VOI with 50% threshold (FTV 50% ). The total skeletal tumour burden, total lesion 18F-fluoride (TLF), was calculated using a threshold of SUV of ≥15. Blood/serum biochemical bone turnover markers obtained at the time of each PET were PSA, ALP, S-osteocalcin, S-beta-CTx, 1CTP and BAP. A total of 47 index lesions and a range of 2-122 bone metastases per patient were evaluated. Median time between 18F-fluoride PET/CT was 7 days (range 6-8 days). Repeatability coefficients were for SUVmax 26%, SUVmean 24%, FTV 50% for index lesions 23% and total skeletal tumour burden (TLF) 35%. Biochemical bone marker repeatability coefficients were for PSA 19%, ALP 23%, S-osteocalcin 18%, S-beta-CTx 22%, 1CTP 18% and BAP 23%. Quantitative 18F-fluoride uptake and simultaneous biochemical bone markers measurements are reproducible for prostate cancer metastases and show similar magnitude in test-retest variation.

  12. Specification and estimation of sources of bias affecting neurological studies in PET/MR with an anatomical brain phantom

    Energy Technology Data Exchange (ETDEWEB)

    Teuho, J., E-mail: jarmo.teuho@tyks.fi [Turku PET Centre, Turku (Finland); Johansson, J. [Turku PET Centre, Turku (Finland); Linden, J. [Turku PET Centre, Turku (Finland); Department of Mathematics and Statistics, University of Turku, Turku (Finland); Saunavaara, V.; Tolvanen, T.; Teräs, M. [Turku PET Centre, Turku (Finland)

    2014-01-11

    Selection of reconstruction parameters has an effect on the image quantification in PET, with an additional contribution from a scanner-specific attenuation correction method. For achieving comparable results in inter- and intra-center comparisons, any existing quantitative differences should be identified and compensated for. In this study, a comparison between PET, PET/CT and PET/MR is performed by using an anatomical brain phantom, to identify and measure the amount of bias caused due to differences in reconstruction and attenuation correction methods especially in PET/MR. Differences were estimated by using visual, qualitative and quantitative analysis. The qualitative analysis consisted of a line profile analysis for measuring the reproduction of anatomical structures and the contribution of the amount of iterations to image contrast. The quantitative analysis consisted of measurement and comparison of 10 anatomical VOIs, where the HRRT was considered as the reference. All scanners reproduced the main anatomical structures of the phantom adequately, although the image contrast on the PET/MR was inferior when using a default clinical brain protocol. Image contrast was improved by increasing the amount of iterations from 2 to 5 while using 33 subsets. Furthermore, a PET/MR-specific bias was detected, which resulted in underestimation of the activity values in anatomical structures closest to the skull, due to the MR-derived attenuation map that ignores the bone. Thus, further improvements for the PET/MR reconstruction and attenuation correction could be achieved by optimization of RAMLA-specific reconstruction parameters and implementation of bone to the attenuation template. -- Highlights: • Comparison between PET, PET/CT and PET/MR was performed with a novel brain phantom. • The performance of reconstruction and attenuation correction in PET/MR was studied. • A recently developed brain phantom was found feasible for PET/MR imaging. • Contrast reduction

  13. Specification and estimation of sources of bias affecting neurological studies in PET/MR with an anatomical brain phantom

    Science.gov (United States)

    Teuho, J.; Johansson, J.; Linden, J.; Saunavaara, V.; Tolvanen, T.; Teräs, M.

    2014-01-01

    Selection of reconstruction parameters has an effect on the image quantification in PET, with an additional contribution from a scanner-specific attenuation correction method. For achieving comparable results in inter- and intra-center comparisons, any existing quantitative differences should be identified and compensated for. In this study, a comparison between PET, PET/CT and PET/MR is performed by using an anatomical brain phantom, to identify and measure the amount of bias caused due to differences in reconstruction and attenuation correction methods especially in PET/MR. Differences were estimated by using visual, qualitative and quantitative analysis. The qualitative analysis consisted of a line profile analysis for measuring the reproduction of anatomical structures and the contribution of the amount of iterations to image contrast. The quantitative analysis consisted of measurement and comparison of 10 anatomical VOIs, where the HRRT was considered as the reference. All scanners reproduced the main anatomical structures of the phantom adequately, although the image contrast on the PET/MR was inferior when using a default clinical brain protocol. Image contrast was improved by increasing the amount of iterations from 2 to 5 while using 33 subsets. Furthermore, a PET/MR-specific bias was detected, which resulted in underestimation of the activity values in anatomical structures closest to the skull, due to the MR-derived attenuation map that ignores the bone. Thus, further improvements for the PET/MR reconstruction and attenuation correction could be achieved by optimization of RAMLA-specific reconstruction parameters and implementation of bone to the attenuation template.

  14. Sensory analysis of pet foods.

    Science.gov (United States)

    Koppel, Kadri

    2014-08-01

    Pet food palatability depends first and foremost on the pet and is related to the pet food sensory properties such as aroma, texture and flavor. Sensory analysis of pet foods may be conducted by humans via descriptive or hedonic analysis, pets via acceptance or preference tests, and through a number of instrumental analysis methods. Sensory analysis of pet foods provides additional information on reasons behind palatable and unpalatable foods as pets lack linguistic capabilities. Furthermore, sensory analysis may be combined with other types of information such as personality and environment factors to increase understanding of acceptable pet foods. Most pet food flavor research is proprietary and, thus, there are a limited number of publications available. Funding opportunities for pet food studies would increase research and publications and this would help raise public awareness of pet food related issues. This mini-review addresses current pet food sensory analysis literature and discusses future challenges and possibilities. © 2014 Society of Chemical Industry.

  15. Centrifugally Spun Recycled PET: Processing and Characterization

    Directory of Open Access Journals (Sweden)

    Phu Phong Vo

    2018-06-01

    Full Text Available Centrifugal spinning, which is a high-productivity fiber fabrication technique, was used to produce a value-added product from recycled poly(ethylene terephthalate (rPET. In the present study, rPET fibers, with fiber diameters ranging from submicron to micrometer in scale, were fabricated by spinning a solution of rPET in a mixture of dichloromethane and trifluoroacetic acid. The influence of the polymer solution concentration (the viscosity, the rotational speed of the spinneret, and the inner diameter of the needles on the formation and morphology and mechanical properties of the fibers were examined through scanning electron microscopy and using a tensile testing machine. The thermal behaviors of fibrous mats with various average diameters were also investigated through differential scanning calorimetry. The smoothest and smallest fibers, with an average diameter of 619 nm, were generated using an rPET solution of 10 wt % under a rotation speed of 15,000 rpm using needles having an inner diameter of 160 μm. The fibrous mats have an average tensile strength and modulus of 4.3 MPa and 34.4 MPa, respectively. The productivity and the mechanical properties indicate that centrifugal spinning is an effective technique to fabricate high-value product from rPET.

  16. The application of PET and PET-CT in cervical cancer

    International Nuclear Information System (INIS)

    Huang Jianmin; Pan Liping; Li Dongxue

    2007-01-01

    Cervical cancer is the common malignancies in woman, 18 F-fluorodeoxyglucose ( 18 F-FDG) PET is a well-established method for detecting, staging, cancer recurrence, therapeutic response and prognosis of cervical cancer. PET-CT can accurately locate the anatomical sites of tracer uptake and improve the diagnostic accuraccy of PET. (authors)

  17. Monitoring proton radiation therapy with in-room PET imaging

    International Nuclear Information System (INIS)

    Zhu Xuping; Ouyang Jinsong; El Fakhri, Georges; Espana, Samuel; Daartz, Juliane; Liebsch, Norbert; Paganetti, Harald; Bortfeld, Thomas R

    2011-01-01

    We used a mobile positron emission tomography (PET) scanner positioned within the proton therapy treatment room to study the feasibility of proton range verification with an in-room, stand-alone PET system, and compared with off-line equivalent studies. Two subjects with adenoid cystic carcinoma were enrolled into a pilot study in which in-room PET scans were acquired in list-mode after a routine fractionated treatment session. The list-mode PET data were reconstructed with different time schemes to generate in-room short, in-room long and off-line equivalent (by skipping coincidences from the first 15 min during the list-mode reconstruction) PET images for comparison in activity distribution patterns. A phantom study was followed to evaluate the accuracy of range verification for different reconstruction time schemes quantitatively. The in-room PET has a higher sensitivity compared to the off-line modality so that the PET acquisition time can be greatly reduced from 30 to 15 O component and lower biological washout. For soft tissue-equivalent material, the distal fall-off edge of an in-room short acquisition is deeper compared to an off-line equivalent scan, indicating a better coverage of the high-dose end of the beam. In-room PET is a promising low cost, high sensitivity modality for the in vivo verification of proton therapy. Better accuracy in Monte Carlo predictions, especially for biological decay modeling, is necessary.

  18. The petit rat (pet/pet), a new semilethal mutant dwarf rat with thymic and testicular anomalies.

    Science.gov (United States)

    Chiba, Junko; Suzuki, Katsushi; Suzuki, Hiroetsu

    2008-12-01

    The petit rat (pet/pet) is a recently discovered semilethal mutant dwarf. The neonatal pet/pet rats had a low body weight and small thymus and testis. During the first 3 d after birth, 50% of the male and 80% of the female pet/pet pups were lost or found dead. Surviving pet/pet rats showed marked retardation of postnatal growth, and their body weights were 41% (female rats) and 32% (male rats) of those of normal rats at the adult stage. The pet/pet rats exhibited proportional dwarfism, and their longitudinal bones were shorter than those of controls without skeletal malformations. Most organs of male pet/pet rats, especially the thymus, testis, adipose tissue surrounding the kidney, and accessory sex organs, weighed markedly less at 140 d of age than did those of their normal counterparts. The thymus of pet/pet rats was small with abnormal thymic follicles. Testes from pet/pet rats exhibited 2 patterns of abnormal histology. Spermatogenesis was present in testes that were only slightly anomalous, but the seminiferous tubules were reduced in diameter. In severely affected testes, most of the seminiferous tubules showed degeneration, and interstitial tissue was increased. Plasma growth hormone concentrations did not differ between pet/pet and normal male rats. The dwarf phenotype of pet/pet rats was inherited as an autosomal recessive trait. These results indicate that the pet/pet rat has a semilethal growth-hormone-independent dwarf phenotype that is accompanied by thymic and testicular anomalies and low birth weight.

  19. Metabolic liver function in humans measured by 2-(18)F-fluoro-2-deoxy-D-galactose PET/CT-reproducibility and clinical potential

    DEFF Research Database (Denmark)

    Bak-Fredslund, Kirstine P; Lykke Eriksen, Peter; Munk, Ole L

    2017-01-01

    Background: PET/CT with the radioactively labelled galactose analogue 2-18F-fluoro-2-deoxy-D-galactose (18F-FDGal) can be used to quantify the hepatic metabolic function and visualise regional metabolic heterogeneity. We determined the day-to-day variation in humans with and without liver disease....... Furthermore, we examined whether the standardised uptake value (SUV) of 18F-FDGal from static scans can substitute the hepatic systemic clearance of 18F- FDGal (Kmet, mL blood/min/mL liver tissue/) quantified from dynamic scans as measure of metabolic function. Four patients with cirrhosis and six healthy...... subjects underwent two 18F-FDGal PET/CT scans within a median interval of 15 days for determination of day-to-day variation. The correlation between Kmet and SUV was examined using scan data and measured arterial blood concentrations of 18F-FDGal (blood samples) from 14 subjects from previous studies...

  20. Value of PET and PET-CT for monitoring tumor therapy

    International Nuclear Information System (INIS)

    Chen Xiang; Zhao Jinhua

    2007-01-01

    18 F-fluorodeoxyglucose ( 18 F-FDG) PET or PET-CT is an accurate test for differentiating residual viable tumor tissue from therapy-induced changes in tumor. Furthermore, quantitative assessment of therapy-induced changes in tumor 18 F-FDG uptake may allow the prediction of tumor response. Treatment may be adjusted according to tumor response. So it is increasingly used to monitor tumor response in patients undergoing chemotherapy and chemoradiotherapy. Here we focused on practical aspects of 18 F-FDG PET or PET-CT for treatment monitoring and on the existing advantages and challenges. (authors)

  1. Denoising of high resolution small animal 3D PET data using the non-subsampled Haar wavelet transform

    International Nuclear Information System (INIS)

    Ochoa Domínguez, Humberto de Jesús; Máynez, Leticia O.; Vergara Villegas, Osslan O.; Mederos, Boris; Mejía, José M.; Cruz Sánchez, Vianey G.

    2015-01-01

    PET allows functional imaging of the living tissue. However, one of the most serious technical problems affecting the reconstructed data is the noise, particularly in images of small animals. In this paper, a method for high-resolution small animal 3D PET data is proposed with the aim to reduce the noise and preserve details. The method is based on the estimation of the non-subsampled Haar wavelet coefficients by using a linear estimator. The procedure is applied to the volumetric images, reconstructed without correction factors (plane reconstruction). Results show that the method preserves the structures and drastically reduces the noise that contaminates the image

  2. Denoising of high resolution small animal 3D PET data using the non-subsampled Haar wavelet transform

    Energy Technology Data Exchange (ETDEWEB)

    Ochoa Domínguez, Humberto de Jesús, E-mail: hochoa@uacj.mx [Departamento de Ingeniería Eléctrica y computación, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico); Máynez, Leticia O. [Departamento de Ingeniería Eléctrica y computación, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico); Vergara Villegas, Osslan O. [Departamento de Ingeniería Industrial, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico); Mederos, Boris; Mejía, José M.; Cruz Sánchez, Vianey G. [Departamento de Ingeniería Eléctrica y computación, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico)

    2015-06-01

    PET allows functional imaging of the living tissue. However, one of the most serious technical problems affecting the reconstructed data is the noise, particularly in images of small animals. In this paper, a method for high-resolution small animal 3D PET data is proposed with the aim to reduce the noise and preserve details. The method is based on the estimation of the non-subsampled Haar wavelet coefficients by using a linear estimator. The procedure is applied to the volumetric images, reconstructed without correction factors (plane reconstruction). Results show that the method preserves the structures and drastically reduces the noise that contaminates the image.

  3. An update on technical and methodological aspects for cardiac PET applications

    International Nuclear Information System (INIS)

    PRESOTTO, Luca; BUSNARDO, Elena; GIANOLLI, Luigi; BETTINARDI, Valentino

    2016-01-01

    Positron emission tomography (PET) is indicated for a large number of cardiac diseases: perfusion and viability studies are commonly used to evaluate coronary artery disease; PET can also be used to assess sarcoidosis and endocarditis, as well as to investigate amyloidosis. Furthermore, a hot topic for research is plaque characterization. Most of these studies are technically very challenging. High count rates and short acquisition times characterize perfusion scans while very small targets have to be imaged in inflammation/infection and plaques examinations. Furthermore, cardiac PET suffers from respiratory and cardiac motion blur. Each type of studies has specific requirements from the technical and methodological point of view, thus PET systems with overall high performances are required. Furthermore, in the era of hybrid PET/computed tomography (CT) and PET/Magnetic Resonance Imaging (MRI) systems, the combination of complementary functional and anatomical information can be used to improve diagnosis and prognosis. Moreover, PET images can be qualitatively and quantitatively improved exploiting information from the other modality, using advanced algorithms. In this review we will report the latest technological and methodological innovations for PET cardiac applications, with particular reference to the state of the art of the hybrid PET/CT and PET/MRI. We will also report the most recent advancements in software, from reconstruction algorithms to image processing and analysis programs.

  4. Processing and characterization of extruded PET and its r-PET and ...

    Indian Academy of Sciences (India)

    of r-PET and r-PET+ MWCNT fillers was obtained by the precipitation method using TFA as a solvent and acetone ... crystallinity in r-PET and decrease in chain entanglements. ..... insufficient to supply the complete information of the surface.

  5. Evaluation of various hepatic lesions with PET

    International Nuclear Information System (INIS)

    Han, Chul Ju

    2000-12-01

    When a liver lesion is found in a PET image, differential diagnosis and analysis of the lesion is very important. We tried to analyze hepatic lesions found in PET. 53 patients with focal liver lesions (13 patients with HCC, 8 patients with cholangiocarcinoma (CC), 20 patients with liver metastasis, 5 patients with hemangioma, 7 patients with liver abscess, including 1 patient with liver candidiasis) were examined. Definitely high FDG uptake pattern were observed in 54% (7/13) of HCC, 100% (8/8) of CC, 95% (19/20) of metastatic liver cancer and 100% (7/7) of liver abscess. Therefore, PET was partially useful in the diagnosis of HCC, but it was very useful in the diagnosis of CC or liver metastasis or liver abscess. The contrast between lesions and surrounding liver background was very conspicuous in PET images of CC or liver metastasis or liver abscess, which suggests that PET might be used for the follow up and assessment of treatment response of these diseases

  6. Evaluation of various hepatic lesions with PET

    Energy Technology Data Exchange (ETDEWEB)

    Han, Chul Ju

    2000-12-01

    When a liver lesion is found in a PET image, differential diagnosis and analysis of the lesion is very important. We tried to analyze hepatic lesions found in PET. 53 patients with focal liver lesions (13 patients with HCC, 8 patients with cholangiocarcinoma (CC), 20 patients with liver metastasis, 5 patients with hemangioma, 7 patients with liver abscess, including 1 patient with liver candidiasis) were examined. Definitely high FDG uptake pattern were observed in 54% (7/13) of HCC, 100% (8/8) of CC, 95% (19/20) of metastatic liver cancer and 100% (7/7) of liver abscess. Therefore, PET was partially useful in the diagnosis of HCC, but it was very useful in the diagnosis of CC or liver metastasis or liver abscess. The contrast between lesions and surrounding liver background was very conspicuous in PET images of CC or liver metastasis or liver abscess, which suggests that PET might be used for the follow up and assessment of treatment response of these diseases.

  7. Current status and prospects of cardiac PET

    International Nuclear Information System (INIS)

    Yoshida, Katuya

    1999-01-01

    With positron emission tomography (PET), noninvasive measurements of myocardial blood flow and metabolism have now become possible. 1) Myocardial blood flow: We developed a high-resolution PET system for rabbits and showed that myocardial N-13 ammonnia uptake correlated well with flow measure with microspheres. We also demonstrated that a simplified PET protocol using N-13 ammonia or Rb-82 provide noninvasive measurement of coronary flow reserve in dog experiments. This protocol enables to produce estimates of myocardial blood flow in man and that are well correlated with the complex compartment model. 2) Myocardial glucose metabolism: We validated experimentally a simple method to quantify tissue glucose utilization with the brain reference index (BRI) using C-14 deoxyglucose and assessed its clinical feasibility for myocardial PET. 3) Membrane integrity: Loss of cell membrane integrity for trapping the potassium or it's analog is a market of myocardial necrosis/viability. We recently synthetized potassium-38 as a PET tracer and started an experimental study. (author)

  8. Clinical PET activities in European and Asia-Oceanian Countries

    International Nuclear Information System (INIS)

    Tashiro, Manabu; Ito, Masatoshi; Yamaguchi, Keiichiro; Kubota, Kazuo; Fujimoto, Toshihiko; Sasaki, Hidetada; Moser, E.

    2001-01-01

    Clinical diagnosis using positron emission tomography (PET) requires high costs. Therefore, sociomedical evaluation is very important for spread of clinical PET. In this report, sociomedical situation in European and Asia-Oceanian countries, especially concerning transportation of 18 F-FDG and reimbursement of medical costs for clinical PET indications, is reported. It seems that UK, Germany and Belgium are the most advanced in clinical PET in Europe. In these countries, many PET investigations are reimbursed though systems are different among the countries. In UK, both public and private insurance gives authorization for clinical PET to some extent. In Germany, private health insurance companies give authorization but public insurance has not. In Belgium, private health insurance does not exist and public insurance gives authorization for clinical PET. Other European countries seem to be in transitional stages. Transportation of 18 F-FDG has been already started in almost every country in Europe and Asia-Oceania. In Japan, neither transportation of FDG nor full reimbursement of clinical PET has not started yet and this situation seems to be exceptional. To promote clinical PET in Japan, there is the need of at least establishing a list of clinical indications for PET investigations and establishing commercial-based 18 F-FDG supplying system. They could be regarded as a kind of infrastructure for spread of clinical PET. (author)

  9. Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition. Detectability for pulmonary lesions compared with respiratory-gated PET/CT

    International Nuclear Information System (INIS)

    Yamashita, Shozo; Yamamoto, Haruki; Hiko, Shigeaki; Horita, Akihiro; Yokoyama, Kunihiko; Onoguchi, Masahisa; Nakajima, Kenichi

    2014-01-01

    Deep-inspiration breath-hold (DIBH) positron emission tomography (PET)/CT with short-time acquisition and respiratory-gated (RG) PET/CT are performed for pulmonary lesions to reduce the respiratory motion artifacts, and to obtain more accurate standardized uptake value (SUV). DIBH PET/CT demonstrates significant advantages in terms of rapid examination, good quality of CT images and low radiation exposure. On the other hand, the image quality of DIBH PET is generally inferior to that of RG PET because of short-time acquisition resulting in poor signal-to-noise ratio. In this study, RG PET has been regarded as a gold standard, and its detectability between DIBH and RG PET studies was compared using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were determined. In the clinical study, 19 cases were examined using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were different. Reconstruction parameters of DIBH PET could be obtained by reducing the number of subsets for those of RG PET in the state of fixing the number of iterations. In the clinical study, high correlation in the maximum SUV was observed between DIBH and RG PET studies. The clinical result was consistent with that of the phantom study surrounded by air since most of the lesions were located in the low pulmonary radioactivity. DIBH PET/CT may be the most practical method which can be the first choice to reduce respiratory motion artifacts if the detectability of DIBH PET is equivalent with that of RG PET. Although DIBH PET may have limitations in suboptimal signal-to-noise ratio, most of the lesions surrounded by low background radioactivity could provide nearly equivalent image quality between DIBH and RG PET studies when each of the most optimal reconstruction parameters was used. (author)

  10. Development of a PET/Cerenkov-light hybrid imaging system

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Hamamura, Fuka; Kato, Katsuhiko; Ogata, Yoshimune; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Hatazawa, Jun; Watabe, Hiroshi

    2014-01-01

    Purpose: Cerenkov-light imaging is a new molecular imaging technology that detects visible photons from high-speed electrons using a high sensitivity optical camera. However, the merit of Cerenkov-light imaging remains unclear. If a PET/Cerenkov-light hybrid imaging system were developed, the merit of Cerenkov-light imaging would be clarified by directly comparing these two imaging modalities. Methods: The authors developed and tested a PET/Cerenkov-light hybrid imaging system that consists of a dual-head PET system, a reflection mirror located above the subject, and a high sensitivity charge coupled device (CCD) camera. The authors installed these systems inside a black box for imaging the Cerenkov-light. The dual-head PET system employed a 1.2 × 1.2 × 10 mm 3 GSO arranged in a 33 × 33 matrix that was optically coupled to a position sensitive photomultiplier tube to form a GSO block detector. The authors arranged two GSO block detectors 10 cm apart and positioned the subject between them. The Cerenkov-light above the subject is reflected by the mirror and changes its direction to the side of the PET system and is imaged by the high sensitivity CCD camera. Results: The dual-head PET system had a spatial resolution of ∼1.2 mm FWHM and sensitivity of ∼0.31% at the center of the FOV. The Cerenkov-light imaging system's spatial resolution was ∼275μm for a 22 Na point source. Using the combined PET/Cerenkov-light hybrid imaging system, the authors successfully obtained fused images from simultaneously acquired images. The image distributions are sometimes different due to the light transmission and absorption in the body of the subject in the Cerenkov-light images. In simultaneous imaging of rat, the authors found that 18 F-FDG accumulation was observed mainly in the Harderian gland on the PET image, while the distribution of Cerenkov-light was observed in the eyes. Conclusions: The authors conclude that their developed PET/Cerenkov-light hybrid imaging

  11. Reliability versus reproducibility

    International Nuclear Information System (INIS)

    Lautzenheiser, C.E.

    1976-01-01

    Defect detection and reproducibility of results are two separate but closely related subjects. It is axiomatic that a defect must be detected from examination to examination or reproducibility of results is very poor. On the other hand, a defect can be detected on each of subsequent examinations for higher reliability and still have poor reproducibility of results

  12. PET and PET/CT in tumour of undetermined origin

    International Nuclear Information System (INIS)

    Garcia O, J.R.

    2007-01-01

    In this presentation the following conclusions were obtained regarding the use of PET and PET/CT in patient with cancer of unknown primary: 1. Detection of the primary one in 1/3 at 1/2 of patient. 2. It detects metastases in other places in 50%. 3. It changes the initial therapy planned in 1/3 at 1/2 of patient. 4. Useful in initial phases of protocol study to limit the other procedures. After standard evaluation. Before advanced protocol. 5. PET/CT study increases the % of primary detection, although in a non significant way vs. PET. 6. They are required more studies to value their utility to a more objective manner. (Author)

  13. Clinical applications of PET/CT

    International Nuclear Information System (INIS)

    Le Ngoc Ha

    2011-01-01

    The purpose of this article is to review the evolution of PET, PET/CT focusing on the technical aspects, PET radiopharmaceutical developments and current clinical applications as well. The newest technologic advances have been reviewed, including improved crystal design, acquisition modes, reconstruction algorithms, etc. These advancements will continue to improve contrast, decrease noise, and increase resolution. Combined PET/CT system provides faster attenuation correction and useful anatomic correlation to PET functional information. A number of new radiopharmaceuticals used for PET imaging have been developed, however, FDG have been considered as the principal PET radiotracer. The current clinical applications of PET and PET/CT are widespread and include oncology, cardiology and neurology. (author)

  14. Applying Amide Proton Transfer MR Imaging to Hybrid Brain PET/MR: Concordance with Gadolinium Enhancement and Added Value to [18F]FDG PET.

    Science.gov (United States)

    Sun, Hongzan; Xin, Jun; Zhou, Jinyuan; Lu, Zaiming; Guo, Qiyong

    2018-06-01

    The purpose of this study is to evaluate the diagnostic concordance and metric correlations of amide proton transfer (APT) imaging with gadolinium-enhanced magnetic resonance imaging (MRI) and 2-deoxy-2-[ 18 F-]fluoro-D-glucose ([ 18 F]FDG) positron emission tomography (PET), using hybrid brain PET/MRI. Twenty-one subjects underwent brain gadolinium-enhanced [ 18 F]FDG PET/MRI prospectively. Imaging accuracy was compared between unenhanced MRI, MRI with enhancement, APT-weighted (APTW) images, and PET based on six diagnostic criteria. Among tumors, the McNemar test was further used for concordance assessment between gadolinium-enhanced imaging, APT imaging, and [ 18 F]FDG PET. As well, the relation of metrics between APT imaging and PET was analyzed by the Pearson correlation analysis. APT imaging and gadolinium-enhanced MRI showed superior and similar diagnostic accuracy. APTW signal intensity and gadolinium enhancement were concordant in 19 tumors (100 %), while high [ 18 F]FDG avidity was shown in only 12 (63.2 %). For the metrics from APT imaging and PET, there was significant correlation for 13 hypermetabolic tumors (P PET in the evaluation of tumor metabolic activity during brain PET/MR studies.

  15. Diagnostic accuracy of 18F-FDG-PET and PET/CT in patients with Ewing sarcoma family tumours: a systematic review and a meta-analysis

    International Nuclear Information System (INIS)

    Treglia, Giorgio; Salsano, Marco; Stefanelli, Antonella; Mattoli, Maria Vittoria; Giordano, Alessandro; Bonomo, Lorenzo

    2012-01-01

    To systematically review and meta-analyse literature data on the diagnostic performance of fluorine-18-fluorodeoxyglucose (FDG) positron emission tomography (PET) and positron emission tomography/computed tomography (PET/CT) in patients with Ewing sarcoma family tumours (ESFT). PubMed/MEDLINE, Embase and Scopus databases were searched for articles that evaluated FDG-PET and PET/CT in patients with ESFT from inception to 31 May 2011. Studies that fulfilled the three following criteria were included in the systematic review: FDG-PET or PET/CT performed in patients with ESFT; articles about the diagnostic accuracy of FDG-PET and PET/CT; sample size of at least 10 patients with ESFT were included. Studies in which there were sufficient data to reassess sensitivity and specificity of FDG-PET or PET/CT in ESFT were included in the meta-analysis, excluding duplicate publications. Finally, pooled sensitivity, pooled specificity and area under the receiver operating characteristic (ROC) curve of FDG-PET or PET/CT in ESFT were calculated. We found 13 studies comprising a total of 342 patients with ESFT. The main findings of the studies included are presented. The meta-analysis of five selected studies provided these results about FDG-PET and PET/CT in ESFT: pooled sensitivity: 96% (95% confidence interval [CI] 91-99%); pooled specificity: 92% (95% CI 87-96%); area under the ROC curve: 0.97. With regard to the staging and restaging of patients with ESFT, the sensitivity, specificity and accuracy of FDG-PET and PET/CT are high; the combination of FDG-PET or PET/CT with conventional imaging is a valuable tool for the staging and restaging of ESFT and has a relevant impact on the treatment strategy plan. (orig.)

  16. New cardiac cameras: single-photon emission CT and PET.

    Science.gov (United States)

    Slomka, Piotr J; Berman, Daniel S; Germano, Guido

    2014-07-01

    Nuclear cardiology instrumentation has evolved significantly in the recent years. Concerns about radiation dose and long acquisition times have propelled developments of dedicated high-efficiency cardiac SPECT scanners. Novel collimator designs, such as multipinhole or locally focusing collimators arranged in geometries that are optimized for cardiac imaging, have been implemented to enhance photon-detection sensitivity. Some of these new SPECT scanners use solid-state photon detectors instead of photomultipliers to improve image quality and to reduce the scanner footprint. These new SPECT devices allow dramatic up to 7-fold reduction in acquisition times or similar reduction in radiation dose. In addition, new hardware for photon attenuation correction allowing ultralow radiation doses has been offered by some vendors. To mitigate photon attenuation artifacts for the new SPECT scanners not equipped with attenuation correction hardware, 2-position (upright-supine or prone-supine) imaging has been proposed. PET hardware developments have been primarily driven by the requirements of oncologic imaging, but cardiac imaging can benefit from improved PET image quality and improved sensitivity of 3D systems. The time-of-flight reconstruction combined with resolution recovery techniques is now implemented by all major PET vendors. These new methods improve image contrast and image resolution and reduce image noise. High-sensitivity 3D PET without interplane septa allows reduced radiation dose for cardiac perfusion imaging. Simultaneous PET/MR hybrid system has been developed. Solid-state PET detectors with avalanche photodiodes or digital silicon photomultipliers have been introduced, and they offer improved imaging characteristics and reduced sensitivity to electromagnetic MR fields. Higher maximum count rate of the new PET detectors allows routine first-pass Rb-82 imaging, with 3D PET acquisition enabling clinical utilization of dynamic imaging with myocardial flow

  17. Evaluation of diagnostic performance of whole-body simultaneous PET/MRI in pediatric lymphoma

    International Nuclear Information System (INIS)

    Ponisio, Maria Rosana; Laforest, Richard; Khanna, Geetika; McConathy, Jonathan

    2016-01-01

    Whole-body 18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) is the standard of care for lymphoma. Simultaneous PET/MRI (magnetic resonance imaging) is a promising new modality that combines the metabolic information of PET with superior soft-tissue resolution and functional imaging capabilities of MRI while decreasing radiation dose. There is limited information on the clinical performance of PET/MRI in the pediatric setting. This study evaluated the feasibility, dosimetry, and qualitative and quantitative diagnostic performance of simultaneous whole-body FDG-PET/MRI in children with lymphoma compared to PET/CT. Children with lymphoma undergoing standard of care FDG-PET/CT were prospectively recruited for PET/MRI performed immediately after the PET/CT. Images were evaluated for quality, lesion detection and anatomical localization of FDG uptake. Maximum and mean standardized uptake values (SUV max/mean ) of normal organs and SUV max of the most FDG-avid lesions were measured for PET/MRI and PET/CT. Estimation of radiation exposure was calculated using specific age-related factors. Nine PET/MRI scans were performed in eight patients (mean age: 15.3 years). The mean time interval between PET/CT and PET/MRI was 51 ± 10 min. Both the PET/CT and PET/MRI exams had good image quality and alignment with complete (9/9) concordance in response assessment. The SUVs from PET/MRI and PET/CT were highly correlated for normal organs (SUV mean r 2 : 0.88, P<0.0001) and very highly for FDG-avid lesions (SUV max r 2 : 0.94, P=0.0002). PET/MRI demonstrated an average percent radiation exposure reduction of 39% ± 13% compared with PET/CT. Simultaneous whole-body PET/MRI is clinically feasible in pediatric lymphoma. PET/MRI performance is comparable to PET/CT for lesion detection and SUV measurements. Replacement of PET/CT with PET/MRI can significantly decrease radiation dose from diagnostic imaging in children. (orig.)

  18. Dual-Modality PET/Ultrasound imaging of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean; Hsu, I.C.

    2005-11-11

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems.

  19. Dual-Modality PET/Ultrasound imaging of the Prostate

    International Nuclear Information System (INIS)

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean; Hsu, I.C.

    2005-01-01

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems

  20. Enhancement of CNT/PET film adhesion by nano-scale modification for flexible all-solid-state supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yu Jin [Department of Materials Science and Engineering, Korea University, Seoul 136-713 (Korea, Republic of); Chung, Haegeun [Department of Environmental Engineering, Konkuk University, Seoul 143-701 (Korea, Republic of); Kim, Min-Seop [Department of Materials Science and Engineering, Korea University, Seoul 136-713 (Korea, Republic of); Kim, Woong, E-mail: woongkim@korea.ac.kr [Department of Materials Science and Engineering, Korea University, Seoul 136-713 (Korea, Republic of)

    2015-11-15

    Graphical abstract: - Highlights: • High integrity supercapacitors are achieved by improving adhesion of CNTs on PET. • Nanostructures on PET substrate significantly enhances the adhesion strength. • A simple RIE process generates the nanostructures on PET surface. • RIE induces hydrophilicity on the PET and further enhances the adhesive strength. • The supercapacitors show good cyclability with high specific capacitance retention. - Abstract: We demonstrate the fabrication of high-integrity flexible supercapacitors using carbon nanotubes (CNTs), polyethylene terephthalate (PET) films, and ion gels. Although both CNTs and PET films are attractive materials for flexible electronics, they have poor adhesion properties. In this work, we significantly improve interfacial adhesion by introducing nanostructures at the interface of the CNT and PET layers. Simple reactive ion etching (RIE) of the PET substrates generates nano-scale roughness on the PET surface. RIE also induces hydrophilicity on the PET surface, which further enhances adhesive strength. The improved adhesion enables high integrity and excellent flexibility of the fabricated supercapacitors, demonstrated over hundreds of bending cycles. Furthermore, the supercapacitors show good cyclability with specific capacitance retention of 87.5% after 10,000 galvanostatic charge–discharge (GCD) cycles. Our demonstration may be important for understanding interfacial adhesion properties in nanoscale and for producing flexible, high-integrity, high-performance energy storage systems.

  1. Enhancement of CNT/PET film adhesion by nano-scale modification for flexible all-solid-state supercapacitors

    International Nuclear Information System (INIS)

    Kang, Yu Jin; Chung, Haegeun; Kim, Min-Seop; Kim, Woong

    2015-01-01

    Graphical abstract: - Highlights: • High integrity supercapacitors are achieved by improving adhesion of CNTs on PET. • Nanostructures on PET substrate significantly enhances the adhesion strength. • A simple RIE process generates the nanostructures on PET surface. • RIE induces hydrophilicity on the PET and further enhances the adhesive strength. • The supercapacitors show good cyclability with high specific capacitance retention. - Abstract: We demonstrate the fabrication of high-integrity flexible supercapacitors using carbon nanotubes (CNTs), polyethylene terephthalate (PET) films, and ion gels. Although both CNTs and PET films are attractive materials for flexible electronics, they have poor adhesion properties. In this work, we significantly improve interfacial adhesion by introducing nanostructures at the interface of the CNT and PET layers. Simple reactive ion etching (RIE) of the PET substrates generates nano-scale roughness on the PET surface. RIE also induces hydrophilicity on the PET surface, which further enhances adhesive strength. The improved adhesion enables high integrity and excellent flexibility of the fabricated supercapacitors, demonstrated over hundreds of bending cycles. Furthermore, the supercapacitors show good cyclability with specific capacitance retention of 87.5% after 10,000 galvanostatic charge–discharge (GCD) cycles. Our demonstration may be important for understanding interfacial adhesion properties in nanoscale and for producing flexible, high-integrity, high-performance energy storage systems.

  2. [PET/CT: protocol aspects and legal controversies].

    Science.gov (United States)

    Gorospe Sarasúa, L; Vicente Bártulos, A; González Gordaliza, C; García Poza, J; Lourido García, D; Jover Díaz, R

    2008-01-01

    The combination of positron emission tomography (PET) and computed tomography (CT) in a single scanner (PET/CT) allows anatomic and metabolic images to be fused and correlated with a high degree of accuracy; this represents a very important landmark in the history of medicine and especially in the area of diagnostic imaging. Nevertheless, the implementation, startup, and operation of a PET/CT scanner presents particularly interesting challenges, because it involves the integration of two well-established and consolidated techniques (CT and PET, which provide complementary information) that have traditionally been carried out in the context of two different specialties (radiology and nuclear medicine). The rapid diffusion of this new integrated technology raises a series of questions related to the optimal protocols for image acquisition, the supervision of the examinations, image interpretation, and reporting, as well as questions related to the legal competence and responsibility of the specialists involved in a PET/CT study. The objective of this article is to approach these aspects from a constructive perspective and to stimulate the dialog between the specialties of radiology and nuclear medicine, with the aim of maximizing the diagnostic potential of PET/CT and thus of providing better care for patients.

  3. PET-CT in endocrinology

    International Nuclear Information System (INIS)

    Parysow, O.; Jager, V.; Racioppi, S.; Mollerach, A.M.; Collaud, C.; Arma, I.

    2008-01-01

    PET/CT scans have reached an important place in the evaluation of endocrine tumors. The metabolic marker 18F-FDG is the most widespread over the world, and, for the time being, it is the only one available in our country. The limitations of this technique in Endocrinology include high differentiation and low aggressiveness of most endocrine tumors, and low detection rate for low cellularity and/or small lesions. Indications for PET/CT scan in these tumors should be precise, due to the fact that not all of these lesions are significantly glucose-avid and to extract the maximum diagnostic efficacy of this modality to achieve the optimum diagnostic accuracy. The most important indication is DTC with high Tg levels and negative 131-Iodine scans. It is advisable to indicate a PET/CT scan in patients with Tg > 10 ng/ml and stimulated TSH (endogenous or exogenous). The aim is to locate recurrences and metastases in order to remove them, either surgically or by any other therapy alternative to 131 I. Due to higher uptake in more aggressive lesions, this study has a high prognostic value. In patients with high Tg levels, negative 131 I scan, and abnormal FDG uptake, the practitioner must act more aggressively in order to remove the pathologic foci, while with a negative FDG -PET scan, the conduct can be expectant, with periodic follow-up. The introduction of other positron-emitting tracers like 124-Iodine, is likely to yield superior quality images and provide better diagnoses. FDG has a limited efficiency in neuroendocrine tumors, unless they show a significant level of dedifferentiation. The scan is indicated in MTC, when calcitonin levels are above 1000 pg/ml, in order to locate the tumor sites. With the introduction of more specific positron-emitting radiopharmaceuticals, such as 18F-DOPA, 68Ga DOTA, 11C methomidate, 11C-hydroxytryptophan and others, it will be possible to study the metabolic-molecular behavior of these tumors with a more accurate approach. (author) [es

  4. Concurrent low brain and high liver uptake on FDG PET are associated with cardiovascular risk factors

    International Nuclear Information System (INIS)

    Nam, Hyun Yeol; Jun, Sung Min; Pak, Kyoung June; Kim, In Joo

    2017-01-01

    Concurrent low brain and high liver uptake are sometimes observed on fluorine-18-labeled fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET). We investigated the potential clinical significance of this uptake pattern related to metabolic syndrome (MS). We retrospectively reviewed data from 264 consecutive males who had undergone general health check-ups, including FDG PET/CT scans. After an overnight fast, the men had their peripheral blood drawn and the levels of various laboratory parameters measured; an FDG PET/CT scan was performed on the same day. We measured the maximum standardized uptake values of the brain and liver from regions of interest manually placed over the frontal cortex at the level of the centrum semiovale and the right lobe of the liver parenchyma, respectively. Fasting blood glucose (FBG; odds ratio [OR] = 1.063, p < 0.001) and glycated hemoglobin (HbA1c; OR = 3.634, p = 0.010) were the strongest predictive factors for low brain FDG uptake, whereas waist circumference (OR = 1.200, p < 0.001) and γ-glutamyl transpeptidase (OR = 1.012, p = 0.001) were the strongest predictive factors for high liver uptake. Eleven subjects (4.2%) showed concurrent low brain and high liver FDG uptake, and all but one of these subjects (90.9%) had MS. Systolic blood pressure, waist circumference, FBG, triglyceride, alanine aminotransferase, insulin resistance (measured by homeostasis model assessment), insulin, HbA1c, and body mass index were higher in subjects with this FDG uptake pattern than in those without (all, p < 0.001). Concurrent low brain and high liver FDG uptake were closely associated with MS. Moreover, subjects with this pattern had higher values for various cardiovascular risk factors than did those without

  5. Concurrent low brain and high liver uptake on FDG PET are associated with cardiovascular risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Hyun Yeol [Dept. of Nuclear Medicine, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon (Korea, Republic of); Jun, Sung Min [Dept. of Nuclear Medicine, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan (Korea, Republic of); Pak, Kyoung June; Kim, In Joo [Dept. of Nuclear Medicine and Biomedical Research Institute, Pusan National University Hospital, Busan (Korea, Republic of)

    2017-04-15

    Concurrent low brain and high liver uptake are sometimes observed on fluorine-18-labeled fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET). We investigated the potential clinical significance of this uptake pattern related to metabolic syndrome (MS). We retrospectively reviewed data from 264 consecutive males who had undergone general health check-ups, including FDG PET/CT scans. After an overnight fast, the men had their peripheral blood drawn and the levels of various laboratory parameters measured; an FDG PET/CT scan was performed on the same day. We measured the maximum standardized uptake values of the brain and liver from regions of interest manually placed over the frontal cortex at the level of the centrum semiovale and the right lobe of the liver parenchyma, respectively. Fasting blood glucose (FBG; odds ratio [OR] = 1.063, p < 0.001) and glycated hemoglobin (HbA1c; OR = 3.634, p = 0.010) were the strongest predictive factors for low brain FDG uptake, whereas waist circumference (OR = 1.200, p < 0.001) and γ-glutamyl transpeptidase (OR = 1.012, p = 0.001) were the strongest predictive factors for high liver uptake. Eleven subjects (4.2%) showed concurrent low brain and high liver FDG uptake, and all but one of these subjects (90.9%) had MS. Systolic blood pressure, waist circumference, FBG, triglyceride, alanine aminotransferase, insulin resistance (measured by homeostasis model assessment), insulin, HbA1c, and body mass index were higher in subjects with this FDG uptake pattern than in those without (all, p < 0.001). Concurrent low brain and high liver FDG uptake were closely associated with MS. Moreover, subjects with this pattern had higher values for various cardiovascular risk factors than did those without.

  6. A modular data acquisition system for high resolution clinical PET scanners

    OpenAIRE

    Sportelli, Giancarlo

    2011-01-01

    En las últimas dos décadas, la Tomografía por Emisión de Positrones (PET) ha demostrado ser una modalidad clave para el estudio de la biología del cúncer y trastornos cardíacos, y para la realizaciún imágenes moleculares, una tecnica que permite la terapia individualizada de la enfermedad [Weissleder01]. La mejor característica de la PET es su sensibilidad: es la tecnica que proporciona imúagenes moleculares con la mayor sensibilidad, y las imúagenes de cuerpo entero que produce no pueden ser...

  7. Routes for the production of isotopes for PET with high intensity deuteron accelerators

    Science.gov (United States)

    Arias de Saavedra, F.; Porras, I.; Praena, J.

    2018-04-01

    Recent advances in accelerator science are opening new possibilities in different fields of physics. In particular, the development of compact linear accelerators that can provide charged particles of low-medium energy (few MeV) with high current (above mA) allows for the study of new possibilities in neutron production and for new routes for the production of radioisotopes. Keeping in mind how radioisotopes are actually produced in dedicated facilities, we have performed a study of alternative reactions to produce PET isotopes induced by low-energy deuterons. We have fitted the EXFOR cross sections data, used the fitted values of the stopping power by Andersen and Ziegler and calculated by numerical integration the production rate of isotopes for charged particles up to 20 MeV. The results for deuterons up to 3 MeV are compared with the ones from cyclotrons, which are able to provide higher energies to the charged projectiles but with lower intensities. Our results indicate that using linear accelerators may be a good alternative for producing PET isotopes, reducing the problem of neutron activation.

  8. (11)C-MK-8278 PET as a tool for pharmacodynamic brain occupancy of histamine 3 receptor inverse agonists.

    Science.gov (United States)

    Van Laere, Koenraad J; Sanabria-Bohórquez, Sandra M; Mozley, David P; Burns, Donald H; Hamill, Terence G; Van Hecken, Anne; De Lepeleire, Inge; Koole, Michel; Bormans, Guy; de Hoon, Jan; Depré, Marleen; Cerchio, Kristine; Plalcza, John; Han, Lingling; Renger, John; Hargreaves, Richard J; Iannone, Robert

    2014-01-01

    The histamine 3 (H3) receptor is a presynaptic autoreceptor in the central nervous system that regulates the synthesis and release of histamine and modulates the release of other major neurotransmitters. H3 receptor inverse agonists (IAs) may be efficacious in the treatment of various central nervous system disorders, including excessive daytime sleepiness, attention deficit hyperactivity disorder, Alzheimer disease, ethanol addiction, and obesity. Using PET and a novel high-affinity and selective radioligand (11)C-MK-8278, we studied the tracer biodistribution, quantification, and brain H3 receptor occupancy (RO) of MK-0249 and MK-3134, 2 potential IA drugs targeting cerebral H3 receptors, in 6 healthy male subjects (age, 19-40 y). The relationship among H3 IA dose, time on target, and peripheral pharmacokinetics was further investigated in 15 healthy male volunteers (age, 18-40 y) with up to 3 PET scans and 3 subjects per dose level. The mean effective dose for (11)C-MK-8278 was 5.4 ± 1.1 μSv/MBq. Human brain kinetics showed rapid high uptake and fast washout. Binding potential values can be assessed using the pons as a reference region, with a test-retest repeatability of 7%. Drug RO data showed low interindividual variability per dose (mean RO SD, 2.1%), and a targeted 90% RO can be reached for both IAs at clinically feasible doses. (11)C-MK-8278 is a useful novel PET radioligand for determination of human cerebral H3 receptor binding and allows highly reproducible in vivo brain occupancy of H3-targeting drugs, hereby enabling the evaluation of novel compounds in early development to select doses and schedules.

  9. Basic study of entire whole-body PET scanners based on the OpenPET geometry

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Eiji, E-mail: rush@nirs.go.j [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan); Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan)

    2010-09-21

    A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.

  10. [18F]FDG PET/MRI vs. PET/CT for whole-body staging in patients with recurrent malignancies of the female pelvis: initial results

    International Nuclear Information System (INIS)

    Beiderwellen, Karsten; Grueneisen, Johannes; Forsting, Michael; Lauenstein, Thomas C.; Umutlu, Lale; Ruhlmann, Verena; Buderath, Paul; Aktas, Bahriye; Heusch, Philipp; Kraff, Oliver

    2015-01-01

    To evaluate the diagnostic potential of PET/MRI with [ 18 F]FDG in recurrent ovarian and cervical cancer in comparison to PET/CT. A group of 19 patients with suspected recurrence of pelvic malignancies (ovarian cancer, 11 patients; cervical cancer, 8 patients) scheduled for an [ 18 F]FDG PET/CT were subsequently enrolled for a PET/MRI. The scan protocol comprised: (1) a T1-W axial VIBE after contrast agent adminstration, (2) an axial T2-W HASTE, (3) a coronal TIRM, (4) an axial DWI, and dedicated MR sequences of the female pelvis including (5) a T1-W VIBE before contrast agent adminstration, (6) a sagittal T2-W TSE, and (7) a sagittal T1-W dynamic VIBE. The datasets (PET/CT, PET/MRI) were rated separately by two readers regarding lesion count, lesion localization, lesion conspicuity (four-point scale), lesion characterization (benign/malignant/indeterminate) and diagnostic confidence (three-point scale). All available data (histology, prior examinations, PET/CT, PET/MRI, follow-up examinations) served as standard of reference. Median values were compared using the Wilcoxon rank sum test. Metastatic lesions were present in 16 of the 19 patients. A total of 78 lesions (malignant, 58; benign, 20) were described. Both PET/CT and PET/MRI allowed correct identification of all malignant lesions and provided equivalent conspicuity (3.86 ± 0.35 for PET/CT, 3.91 ± 0.28 for PET/MRI; p > 0.05). Diagnostic confidence was significantly higher for PET/MRI in malignant (p < 0.01) and benign lesions (p < 0.05). Both PET/CT and PET/MRI offer an equivalently high diagnostic value for recurrent pelvic malignancies. PET/MRI offers higher diagnostic confidence in the discrimination of benign and malignant lesions. Considering the reduced radiation dose and superior lesion discrimination, PET/MRI may serve as a powerful alternative to PET/CT in the future. (orig.)

  11. PET application in psychiatry and psychopharmacology

    Energy Technology Data Exchange (ETDEWEB)

    Suhara, Tetsuya [National Inst. of Radiological Sciences, Chiba (Japan)

    1999-07-01

    In the last few decades diagnostic and research tools in the medical field have made great advances, yet psychiatry has lacked sufficiently sensitive tools to measure the aberration of brain functions. Recently however, the development of Positron emission tomography (PET) techniques has made it possible to measure changes in neurochemical components in mental disorders and the effect of psychoactive drugs in living human brain. Most of the advancement in the psychiatric field has came from the development psychoactive drugs. Brain research involving identification of neurotransmission is largely based on compounds developed in psychopharmacology. Some of these compounds have been radiolabelled and used as radioligands for quantitative examination of neuroreceptors and other aspects of neurotransmission. Using PET, radioligand binding can now be examined in the human brain in vivo. PET techniques also allow examination of an unlabelled drug by examination of its interaction with a radioligand. So one potential of PET in psychiatry is to investigate the mechanism of psychoactive drugs. Antidepressants modulate serotonin transmission by inhibiting serotonin reuptake from the synaptic cleft. High affinity [{sup 3}H]imipramine binding sites in mammalian brain have been labelled to investigate serotonin transporters in living human brain by PET. Cyanoimipramine which is described as a potent serotonin reuptake inhibitor, was labelled with {sup 11}C. In a PET experiment with 6 healthy human subjects, a high accumulation of [{sup 11}C]cyanoimipramine was found in the thalamus and striatum and lowest accumulation was observed in the cerebellum, a region relatively void of serotonin transporters. The thalamus to cerebellum ratio was about 2 at 90 min after the injection of the tracer. Recently, [{sup 11}C]McN5652-X has been introduced as a better tracer for serotonin transporter imaging. Employing [{sup 11}C]McN5652-X in a PET study of 7 healthy human subjects, a high

  12. PET application in psychiatry and psychopharmacology

    International Nuclear Information System (INIS)

    Suhara, Tetsuya

    1999-01-01

    In the last few decades diagnostic and research tools in the medical field have made great advances, yet psychiatry has lacked sufficiently sensitive tools to measure the aberration of brain functions. Recently however, the development of Positron emission tomography (PET) techniques has made it possible to measure changes in neurochemical components in mental disorders and the effect of psychoactive drugs in living human brain. Most of the advancement in the psychiatric field has came from the development psychoactive drugs. Brain research involving identification of neurotransmission is largely based on compounds developed in psychopharmacology. Some of these compounds have been radiolabelled and used as radioligands for quantitative examination of neuroreceptors and other aspects of neurotransmission. Using PET, radioligand binding can now be examined in the human brain in vivo. PET techniques also allow examination of an unlabelled drug by examination of its interaction with a radioligand. So one potential of PET in psychiatry is to investigate the mechanism of psychoactive drugs. Antidepressants modulate serotonin transmission by inhibiting serotonin reuptake from the synaptic cleft. High affinity [ 3 H]imipramine binding sites in mammalian brain have been labelled to investigate serotonin transporters in living human brain by PET. Cyanoimipramine which is described as a potent serotonin reuptake inhibitor, was labelled with 11 C. In a PET experiment with 6 healthy human subjects, a high accumulation of [ 11 C]cyanoimipramine was found in the thalamus and striatum and lowest accumulation was observed in the cerebellum, a region relatively void of serotonin transporters. The thalamus to cerebellum ratio was about 2 at 90 min after the injection of the tracer. Recently, [ 11 C]McN5652-X has been introduced as a better tracer for serotonin transporter imaging. Employing [ 11 C]McN5652-X in a PET study of 7 healthy human subjects, a high accumulation was observed

  13. Trends in PET imaging

    International Nuclear Information System (INIS)

    Moses, William W.

    2000-01-01

    Positron Emission Tomography (PET) imaging is a well established method for obtaining information on the status of certain organs within the human body or in animals. This paper presents an overview of recent trends PET instrumentation. Significant effort is being expended to develop new PET detector modules, especially those capable of measuring depth of interaction. This is aided by recent advances in scintillator and pixellated photodetector technology. The other significant area of effort is development of special purpose PET cameras (such as for imaging breast cancer or small animals) or cameras that have the ability to image in more than one modality (such as PET / SPECT or PET / X-Ray CT)

  14. Geo-PET: A novel generic organ-pet for small animal organs and tissues

    Science.gov (United States)

    Sensoy, Levent

    Reconstructed tomographic image resolution of small animal PET imaging systems is improving with advances in radiation detector development. However the trend towards higher resolution systems has come with an increase in price and system complexity. Recent developments in the area of solid-state photomultiplication devices like silicon photomultiplier arrays (SPMA) are creating opportunities for new high performance tools for PET scanner design. Imaging of excised small animal organs and tissues has been used as part of post-mortem studies in order to gain detailed, high-resolution anatomical information on sacrificed animals. However, this kind of ex-vivo specimen imaging has largely been limited to ultra-high resolution muCT. The inherent limitations to PET resolution have, to date, excluded PET imaging from these ex-vivo imaging studies. In this work, we leverage the diminishing physical size of current generation SPMA designs to create a very small, simple, and high-resolution prototype detector system targeting ex-vivo tomographic imaging of small animal organs and tissues. We investigate sensitivity, spatial resolution, and the reconstructed image quality of a prototype small animal PET scanner designed specifically for imaging of excised murine tissue and organs. We aim to demonstrate that a cost-effective silicon photomultiplier (SiPM) array based design with thin crystals (2 mm) to minimize depth of interaction errors might be able to achieve sub-millimeter resolution. We hypothesize that the substantial decrease in sensitivity associated with the thin crystals can be compensated for with increased solid angle detection, longer acquisitions, higher activity and wider acceptance energy windows (due to minimal scatter from excised organs). The constructed system has a functional field of view (FoV) of 40 mm diameter, which is adequate for most small animal specimen studies. We perform both analytical (3D-FBP) and iterative (ML-EM) methods in order to

  15. High-Speed Data Acquisition and Digital Signal Processing System for PET Imaging Techniques Applied to Mammography

    Science.gov (United States)

    Martinez, J. D.; Benlloch, J. M.; Cerda, J.; Lerche, Ch. W.; Pavon, N.; Sebastia, A.

    2004-06-01

    This paper is framed into the Positron Emission Mammography (PEM) project, whose aim is to develop an innovative gamma ray sensor for early breast cancer diagnosis. Currently, breast cancer is detected using low-energy X-ray screening. However, functional imaging techniques such as PET/FDG could be employed to detect breast cancer and track disease changes with greater sensitivity. Furthermore, a small and less expensive PET camera can be utilized minimizing main problems of whole body PET. To accomplish these objectives, we are developing a new gamma ray sensor based on a newly released photodetector. However, a dedicated PEM detector requires an adequate data acquisition (DAQ) and processing system. The characterization of gamma events needs a free-running analog-to-digital converter (ADC) with sampling rates of more than 50 Ms/s and must achieve event count rates up to 10 MHz. Moreover, comprehensive data processing must be carried out to obtain event parameters necessary for performing the image reconstruction. A new generation digital signal processor (DSP) has been used to comply with these requirements. This device enables us to manage the DAQ system at up to 80 Ms/s and to execute intensive calculi over the detector signals. This paper describes our designed DAQ and processing architecture whose main features are: very high-speed data conversion, multichannel synchronized acquisition with zero dead time, a digital triggering scheme, and high throughput of data with an extensive optimization of the signal processing algorithms.

  16. Self-consolidating concretes containing waste PET bottles as sand replacement

    Science.gov (United States)

    Khalid, Faisal Sheikh; Azmi, Nurul Bazilah; Mazenan, Puteri Natasya; Shahidan, Shahiron; Othman, Nor hazurina; Guntor, Nickholas Anting Anak

    2018-02-01

    This study evaluates the effect of self-consolidating concrete (SCC) containing waste polyethylene terephthalate (PET) granules on the fresh, mechanical and water absorption properties. Fine aggregates were replaced from 0% to 8% by PET granules. The fresh properties of SCC containing PET granules were determined using slump flow and V-funnel flow time tests. The compressive and splitting tensile strength were evaluated. The results indicated that utilization of waste PET granules in production of SCC could be an effective way for recycling purpose. The maximum amount of PET replacement should be limited to 5%. Exceeding 5% of PET content may result in an increase of V-funnel flow time to overpass the limiting value, decrease in strength. The production of high performance SCC containing 5% PET granules satisfies all the requirements for SCC with satisfactory outputs.

  17. Imaging corn plants with PhytoPET, a modular PET system for plant biology

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.; Kross, B.; McKisson, J.; McKisson, J. E.; Weisenberger, A. G.; Xi, W.; Zorn, C.; Bonito, G.; Howell, C. R.; Reid, C. D.; Crowell, A.; Cumberbatch, L. C.; Topp, C.; Smith, M. F.

    2013-11-01

    PhytoPET is a modular positron emission tomography (PET) system designed specifically for plant imaging. The PhytoPET design allows flexible arrangements of PET detectors based on individual standalone detector modules built from single Hamamatsu H8500 position sensitive photomultiplier tubes and pixelated LYSO arrays. We have used the PhytoPET system to perform preliminary corn plant imaging studies at the Duke University Biology Department Phytotron. Initial evaluation of the PhytoPET system to image the biodistribution of the positron emitting tracer {sup 11}C in corn plants is presented. {sup 11}CO{sub 2} is loaded into corn seedlings by a leaf-labeling cuvette and translocation of {sup 11}C-sugars is imaged by a flexible arrangement of PhytoPET modules on each side. The PhytoPET system successfully images {sup 11}C within corn plants and allows for the dynamic measurement of {sup 11}C-sugar translocation from the leaf to the roots.

  18. Oncology PET imaging

    International Nuclear Information System (INIS)

    Inubushi, Masayuki

    2014-01-01

    At the beginning of this article, likening medical images to 'Where is Waldo?' I indicate the concept of diagnostic process of PET/CT imaging, so that medical physics specialists could understand the role of each imaging modality and infer our distress for image diagnosis. Then, I state the present situation of PET imaging and the basics (e.g. health insurance coverage, clinical significance, principle, protocol, and pitfall) of oncology FDG-PET imaging which accounts for more than 99% of all clinical PET examinations in Japan. Finally, I would like to give a wishful prospect of oncology PET that will expand to be more cancer-specific in order to assess therapeutic effects of emerging molecular targeted drugs targeting the 'hallmarks of cancer'. (author)

  19. Prediction of cervical cancer recurrence using textural features extracted from 18F-FDG PET images acquired with different scanners.

    Science.gov (United States)

    Reuzé, Sylvain; Orlhac, Fanny; Chargari, Cyrus; Nioche, Christophe; Limkin, Elaine; Riet, François; Escande, Alexandre; Haie-Meder, Christine; Dercle, Laurent; Gouy, Sébastien; Buvat, Irène; Deutsch, Eric; Robert, Charlotte

    2017-06-27

    To identify an imaging signature predicting local recurrence for locally advanced cervical cancer (LACC) treated by chemoradiation and brachytherapy from baseline 18F-FDG PET images, and to evaluate the possibility of gathering images from two different PET scanners in a radiomic study. 118 patients were included retrospectively. Two groups (G1, G2) were defined according to the PET scanner used for image acquisition. Eleven radiomic features were extracted from delineated cervical tumors to evaluate: (i) the predictive value of features for local recurrence of LACC, (ii) their reproducibility as a function of the scanner within a hepatic reference volume, (iii) the impact of voxel size on feature values. Eight features were statistically significant predictors of local recurrence in G1 (p features were significantly different between G1 and G2 in the liver. Spatial resampling was not sufficient to explain the stratification effect. This study showed that radiomic features could predict local recurrence of LACC better than SUVmax. Further investigation is needed before applying a model designed using data from one PET scanner to another.

  20. CyberPET: a PET service distributed over a wide area

    International Nuclear Information System (INIS)

    Pilloy, W.J.; Hellwig, D.; Schaeffer, A.; Hoffmann, P.; Lens, V.

    2002-01-01

    Aim: Demonstration of bi-directional PET data transmission, interactive display and co-registration, for the purpose of correlative imaging, treatment planning and teaching. Material and Method: In the year 2000, the initial problem to attend was to provide an effective PET service to a hospital (in Luxemburg) which lies 150 km away from a PET center (in another country). Once this solved, the procedure was expanded (in 2001) to co-registration with CT/MRI scans performed locally, and with radiotherapy simulation CT performed in another center 25 km away (in 2002). Equipment from various vendors was used (Siemens, Adac, GE, Hermes). With preliminary agreement of the national medical aid, patients are sent from the Nuclear Medicine Dept of the Centre Hospitalier in Luxemburg (CHL) to the Dept NM of the Saarland University Medical Center for PET examination. The digital data are then sent from the Siemens PET camera to a PC connected to the LAN, and then to a FTP server (Healthnet). The data are similarly collected by a PC of the hospital network in Luxemburg, and transferred to a Hermes NM station. The Dicom PET data are converted on the fly to Interfile, displayed interactively as any other tomographic data, printed and available on the NM image server. Since 2001, the PET data are co-registered with whole-body CT data recorded at CHL according to a specific protocol (see other paper of this group). Now in 2002, we are busy implementing the co-registration of PET data and simulation CT data obtained from the Centre Baclesse (CFB, 25 km from CHL) for the treatment planning of brain tumours (input into an ADAC system). Furthermore, we plan to send the data (after deletion of their digital ID) to a (South African) university which does not yet dispose of a PET camera, to allow the training of their registrars. Results: For the end-user clinician at CHL and CFB , the PET data have the quality of 'live data', which can be examined interactively, along with other imaging

  1. Triroc: A Multi-Channel SiPM Read-Out ASIC for PET/PET-ToF Application

    Science.gov (United States)

    Ahmad, Salleh; Fleury, Julien; de la Taille, Christophe; Seguin-Moreau, Nathalie; Dulucq, Frederic; Martin-Chassard, Gisele; Callier, Stephane; Thienpont, Damien; Raux, Ludovic

    2015-06-01

    Triroc is the latest addition to SiPM readout ASICs family developed at Weeroc, a start-up company from the Omega microelectronics group of IN2P3/CNRS. This chip is developed under the framework TRIMAGE European project which is aimed for building a cost effective tri-modal PET/MR/EEG brain scan. To ensure the flexibility and compatibility with any SiPM in the market, the ASIC is designed to be capable of accepting negative and positive polarity input signals. This 64-channel ASIC, is suitable for SiPM readout which requires high accuracy timing and charge measurements. Targeted applications would be PET prototyping with time-of-flight capability. Main features of Triroc includes high dynamic range ADC up to 2500 photoelectrons and TDC fine time binning of 40 ps. Triroc requires very minimal external components which means it is a good contender for compact multichannel PET prototyping. Triroc is designed by using AMS 0.35 μm SiGe technology and it was submitted in March 2014. The detail design of this chip will be presented.

  2. CNS metabolism in high-risk drug abuse, German version. Insights gained from {sup 1}H- and {sup 31}P MRS and PET; ZNS-Stoffwechsel bei Missbrauch von Hochrisikodrogen. Erkenntnisse durch {sup 1}H- und {sup 31}P-MRS sowie PET

    Energy Technology Data Exchange (ETDEWEB)

    Bodea, S.V. [Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany)

    2017-06-15

    High-risk drug consumption is a considerable problem for public health actors in industrialised countries. The latest trends show a market tendency towards diversification and increasing demand for high-purity synthetic drugs. Whilst most consumers seek medical help after cannabis use, it is high-risk drugs like cocaine, heroin and amphetamines that account for most of the 1000 drug-related deaths that occur in Germany every year. This article presents the most prominent in vivo cerebral metabolic information in cocaine, heroin and methamphetamine users provided by MRI spectroscopy and PET imaging. We reviewed the literature reporting neuroimaging studies of in vivo metabolic data for methamphetamine, cocaine and heroin consumption published up to March 2017. The search was conducted using PubMed with the following key words: methamphetamine, cocaine, heroin, MR spectroscopy, PET. MRI and PET are indispensable tools in gauging brain metabolic response to illegal drug abuse. Future breakthroughs in this field will most likely come from the investigation of novel neurotransmitter systems in PET and imaging phosphorus and carbon metabolites in MRI. (orig.) [German] In den Industrielaendern ist der Konsum von Hochrisikodrogen ein erhebliches Problem fuer das gesamte Gesundheitssystem. Neueste Entwicklungen zeigen eine Tendenz zu immer groesserer Diversifikation und eine erhoehte Nachfrage nach synthetischen Drogen von hohem Reinheitsgrad. Waehrend die meisten Konsumenten medizinische Hilfe nach Cannabisverbrauch suchen, sind es die Hochrisikodrogen wie Heroin, Kokain und Amphetamine, an denen die meisten der 1000 Drogentoten pro Jahr in Deutschland sterben. In diesem Artikel werden die auffaelligsten, mithilfe der Magnetresonanzspektroskopie (MRS) und Positronenemissionstomographie (PET) erfassten In-vivo-Daten zum Hirnstoffwechsel bei Konsumenten von Kokain, Heroin und Methamphetaminen vorgestellt. Die Literatur ueber den zerebralen Energiestoffwechsel bei

  3. Comparison of PET/CT and PET/MRI hybrid systems using a 68Ga-labelled PSMA ligand for the diagnosis of recurrent prostate cancer: initial experience

    International Nuclear Information System (INIS)

    Afshar-Oromieh, A.; Haberkorn, U.; Schlemmer, H.P.; Fenchel, M.; Roethke, M.; Eder, M.; Eisenhut, M.; Hadaschik, B.A.; Kopp-Schneider, A.

    2014-01-01

    68 Ga-labelled HBED-CC-PSMA is a highly promising tracer for imaging recurrent prostate cancer (PCa). The intention of this study was to evaluate the feasibility of PET/MRI with this tracer. Twenty patients underwent PET/CT 1 h after injection of the 68 Ga-PSMA ligand followed by PET/MRI 3 h after injection. Data from the two investigations were first analysed separately and then compared with respect to tumour detection rate and radiotracer uptake in various tissues. To evaluate the quantification accuracy of the PET/MRI system, differences in SUVs between PET/CT and corresponding PET/MRI were compared with differences in SUVs between PET/CT 1 h and 3 h after injection in another patient cohort. This cohort was investigated using the same PET/CT system. With PET/MRI, different diagnostic sequences, higher contrast of lesions and higher resolution of MRI enabled a subjectively easier evaluation of the images. In addition, four unclear findings on PET/CT could be clarified as characteristic of PCa metastases by PET/MRI. However, in PET images of the PET/MRI, a reduced signal was observed at the level of the kidneys (in 11 patients) and around the urinary bladder (in 15 patients). This led to reduced SUVs in six lesions. SUV mean values provided by the PET/MRI system were different in muscles, blood pool, liver and spleen. PCa was detected more easily and more accurately with Ga-PSMA PET/MRI than with PET/CT and with lower radiation exposure. Consequently, this new technique could clarify unclear findings on PET/CT. However, scatter correction was challenging when the specific 68 Ga-PSMA ligand was used. Moreover, direct comparison of SUVs from PET/CT and PET/MR needs to be conducted carefully. (orig.)

  4. Non-FDG PET imaging of brain tumors

    Institute of Scientific and Technical Information of China (English)

    HUANG Zemin; GUAN Yihui; ZUO Chuantao; ZHANG Zhengwei; XUE Fangping; LIN Xiangtong

    2007-01-01

    Due to relatively high uptake of glucose in the brain cortex, the use of FDG PET imaging is greatly limited in brain tumor imaging, especially for low-grade gliomas and some metastatic tumours. More and more tracers with higher specificity were developed lately for brain tumor imaging. There are 3 main types of non-FDG PET tracers:amino acid tracers, choline tracers and nucleic acid tracers. These tracers are now widely applied in many aspects of brain tumor imaging. This article summarized the general use of non-FDG PET in different aspects of brain tumor imaging.

  5. Childhood Attachment to Pets: Associations between Pet Attachment, Attitudes to Animals, Compassion, and Humane Behaviour

    Directory of Open Access Journals (Sweden)

    Roxanne D. Hawkins

    2017-05-01

    Full Text Available Attachment to pets has an important role in children’s social, emotional, and cognitive development, mental health, well-being, and quality of life. This study examined associations between childhood attachment to pets and caring and friendship behaviour, compassion, and attitudes towards animals. This study also examined socio-demographic differences, particularly pet ownership and pet type. A self-report survey of over one thousand 7 to 12 year-olds in Scotland, UK, revealed that the majority of children are strongly attached to their pets, but attachment scores differ depending on pet type and child gender. Analysis revealed that attachment to pets is facilitated by compassion and caring and pet-directed friendship behaviours and that attachment to pets significantly predicts positive attitudes towards animals. The findings have implications for the promotion of prosocial and humane behaviour. Encouraging children to participate in pet care behaviour may promote attachment between children and their pet, which in turn may have a range of positive outcomes for both children (such as reduced aggression, better well-being, and quality of life and pets (such as humane treatment. This study enhances our understanding of childhood pet attachment and has implications for humane education and promoting secure emotional attachments in childhood.

  6. Usefulness of PET in non-lesional temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Bertuluchi, M.; Arganaraz, R.; Buznick, J.; Pomata, H.

    2011-01-01

    Objective. To evaluate the usefulness of PET in patients with refractory non-lesional temporal lobe epilepsy. Material and methods. We present three patients with features of temporal lobe epilepsy refractory to medication, where high definition MRI was normal. Results. These patients had PET hypometabolism in the temporal areas related to clinical and neurophysiological findings. Two of these patients were implanted with subdural grids to confirm the diagnosis and the third was operated directly based on the findings of PET. Encourage the presentation of the importance in recent years is acquiring the PET. Conclusion. In those patients in clinical neurophysiology and epilepsy with suspected temporal lobe, but in the MRI images show no structural lesions, PET can play an important role defining the diagnosis. (authors)

  7. Selecting Safe Pets (For Parents)

    Science.gov (United States)

    ... supplies (pet bowls, pet bed, leash, etc.) as gifts, then selecting the pet as a family. That way, everyone has time to really think about whether your family is ready for a pet. Key Questions Before adopting or purchasing any pet, talk to all family members, discuss ...

  8. Impact of a second FDG PET scan before adjuvant therapy for the early detection of residual/relapsing tumours in high-risk patients with oral cavity cancer and pathological extracapsular spread

    Energy Technology Data Exchange (ETDEWEB)

    Liao, Chun-Ta; Huang, Shiang-Fu; Chen, I-How; Kang, Chung-Jan [Chang Gung Memorial Hospital and Chang Gung University, Department of Otorhinolaryngology, Head and Neck Surgery, Taoyuan (China); Chang Gung Memorial Hospital and Chang Gung University, Head and Neck Oncology Group, Taoyuan (China); Fan, Kang-Hsing; Lin, Chien-Yu [Chang Gung Memorial Hospital and Chang Gung University, Head and Neck Oncology Group, Taoyuan (China); Chang Gung Memorial Hospital and Chang Gung University, Department of Radiation Oncology, Taoyuan (China); Wang, Hung-Ming [Chang Gung Memorial Hospital and Chang Gung University, Head and Neck Oncology Group, Taoyuan (China); Chang Gung Memorial Hospital and Chang Gung University, Department of Medical Oncology, Taoyuan (China); Ng, Shu-Hang [Chang Gung Memorial Hospital and Chang Gung University, Head and Neck Oncology Group, Taoyuan (China); Chang Gung Memorial Hospital and Chang Gung University, Department of Diagnostic Radiology, Taoyuan (China); Hsueh, Chuen; Lee, Li-Yu [Chang Gung Memorial Hospital and Chang Gung University, Head and Neck Oncology Group, Taoyuan (China); Chang Gung Memorial Hospital and Chang Gung University, Department of Pathology, Taoyuan (China); Lin, Chih-Hung [Chang Gung Memorial Hospital and Chang Gung University, Head and Neck Oncology Group, Taoyuan (China); Chang Gung Memorial Hospital and Chang Gung University, Department of Plastic and Reconstructive Surgery, Taoyuan (China); Yen, Tzu-Chen [Chang Gung Memorial Hospital and Chang Gung University, Head and Neck Oncology Group, Taoyuan (China); Chang Gung Memorial Hospital and Chang Gung University, Department of Nuclear Medicine and Molecular Imaging Center, Taoyuan (China)

    2012-06-15

    Extracapsular spread (ECS) to the cervical lymph nodes is a major adverse prognostic factor in oral cavity squamous cell carcinoma (OSCC). We prospectively examined the value of FDG PET immediately before postoperative radiotherapy/concurrent chemoradiotherapy (pre-RT/CCRT PET) to detect residual/relapsing disease in the early postsurgical follow-up period in high-risk OSCC patients with ECS. We examined 183 high-risk OSCC patients with ECS who underwent preoperative FDG PET/CT for staging purposes. Of these patients, 29 underwent a second pre-RT/CCRT FDG PET/CT scan. The clinical utility of the second FDG PET/CT was examined using Kaplan-Meier curve analysis. Patients who underwent the second FDG PET/CT scan had baseline clinicopathological characteristics similar to those who did not undergo a second scan. Of the patients who underwent the second scan, seven (24 %) had unexpected, newly discovered lesions. Five eventually died of the disease, and two had no evidence of recurrence after a change in RT field and dose. In an event-based analysis at 2 months, rates of neck control (6/29 vs. 6/154, p = 0.001), distant metastases (3/29 vs. 4/154, p = 0.046), and disease-free survival (7/29 vs. 10/154, p = 0.003) were significantly higher in patients who received a second PET scan than in those who did not. The second pre-RT/CCRT PET scan was of particular benefit for detecting new lesions in OSCC patients with both ECS and lymph node standardized uptake value (SUV) of {>=}5.2 in the first PET scan. The present findings support the clinical value of pre-RT/CCRT FDG PET for defining treatment strategy in OSCC patients with both ECS and high nodal SUV, even when FDG PET had already been performed during the initial staging work-up. (orig.)

  9. Clinical Applications of FDG PET and PET/CT in Head and Neck Cancer

    Directory of Open Access Journals (Sweden)

    Akram Al-Ibraheem

    2009-01-01

    Full Text Available 18F-FDG PET plays an increasing role in diagnosis and management planning of head and neck cancer. Hybrid PET/CT has promoted the field of molecular imaging in head and neck cancer. This modality is particular relevant in the head and neck region, given the complex anatomy and variable physiologic FDG uptake patterns. The vast majority of 18F-FDG PET and PET/CT applications in head and neck cancer related to head and neck squamous cell carcinoma. Clinical applications of 18F-FDG PET and PET/CT in head and neck cancer include diagnosis of distant metastases, identification of synchronous 2nd primaries, detection of carcinoma of unknown primary and detection of residual or recurrent disease. Emerging applications are precise delineation of the tumor volume for radiation treatment planning, monitoring treatment, and providing prognostic information. The clinical role of 18F-FDG PET/CT in N0 disease is limited which is in line with findings of other imaging modalities. MRI is usually used for T staging with an intense discussion concerning the preferable imaging modality for regional lymph node staging as PET/CT, MRI, and multi-slice spiral CT are all improving rapidly. Is this review, we summarize recent literature on 18F-FDG PET and PET/CT imaging of head and neck cancer.

  10. 2D imaging simulations of a small animal PET scanner with DOI measurement. jPET-RD

    International Nuclear Information System (INIS)

    Yamaya, Taiga; Hagiwara, Naoki

    2005-01-01

    We present a preliminary study on the design of a high sensitivity small animal depth of interaction (DOI)-PET scanner: jPET-RD (for Rodents with DOI detectors), which will contribute to molecular imaging. The 4-layer DOI block detector for the jPET-RD that consists of scintillation crystals (1.4 mm x 1.4 mm x 4.5 mm) and a flat panel position-sensitive photomultiplier tube (52 mm x 52 mm) was previously proposed. In this paper, we investigate imaging performance of the jPET-RD through numerical simulations. The scanner has a hexagonal geometry with a small diameter and a large axial aperture. Therefore DOI information is expected to improve resolution uniformity in the whole field of view (FOV). We simulate the scanner for various parameters of the number of DOI channels and the crystal length. Simulated data are reconstructed using the maximum likelihood expectation maximization with accurate system modeling. The trade-off results between background noise and spatial resolution show that only shortening the length of crystal does not improve the trade-off at all, and that 4-layer DOI information improves uniformity of spatial resolution in the whole FOV. Excellent performance of the jPET-RD can be expected based on the numerical simulation results. (author)

  11. A retrospective comparison between 68Ga-DOTA-TOC PET/CT and 18F-DOPA PET/CT in patients with extra-adrenal paraganglioma.

    Science.gov (United States)

    Kroiss, Alexander; Putzer, Daniel; Frech, Andreas; Decristoforo, Clemens; Uprimny, Christian; Gasser, Rudolf Wolfgang; Shulkin, Barry Lynn; Url, Christoph; Widmann, Gerlig; Prommegger, Rupert; Sprinzl, Georg Mathias; Fraedrich, Gustav; Virgolini, Irene Johanna

    2013-12-01

    (18)F-Fluoro-L-dihydroxyphenylalanine ((18)F-DOPA) PET offers high sensitivity and specificity in the imaging of nonmetastatic extra-adrenal paragangliomas (PGL) but lower sensitivity in metastatic or multifocal disease. These tumours are of neuroendocrine origin and can be detected by (68)Ga-DOTA-Tyr(3)-octreotide ((68)Ga-DOTA-TOC) PET. Therefore, we compared (68)Ga-DOTA-TOC and (18)F-DOPA as radiolabels for PET/CT imaging for the diagnosis and staging of extra-adrenal PGL. Combined cross-sectional imaging was the reference standard. A total of 5 men and 15 women (age range 22 to 73 years) with anatomical and/or histologically proven extra-adrenal PGL were included in this study. Of these patients, 5 had metastatic or multifocal lesions and 15 had single sites of disease. Comparative evaluation included morphological imaging with CT and functional imaging with (68)Ga-DOTA-TOC PET and (18)F-DOPA PET. The imaging results were analysed on a per-patient and a per-lesion basis. The maximum standardized uptake value (SUVmax) of each functional imaging modality in concordant tumour lesions was measured. Compared with anatomical imaging, (68)Ga-DOTA-TOC PET and (18)F-DOPA PET each had a per-patient and per-lesion detection rate of 100% in nonmetastatic extra-adrenal PGL. However, in metastatic or multifocal disease, the per-lesion detection rate of (68)Ga-DOTA-TOC was 100% and that of (18)F-DOPA PET was 56.0%. Overall, (68)Ga-DOTA-TOC PET identified 45 lesions; anatomical imaging identified 43 lesions, and (18)F-DOPA PET identified 32 lesions. The overall per-lesion detection rate of (68)Ga-DOTA-TOC PET was 100% (McNemar, P TOC PET and 11.8 ± 7.9 for (18)F-DOPA PET (Mann-Whitney U test, P TOC PET may be superior to (18)F-DOPA PET and diagnostic CT in providing valuable information for pretherapeutic staging of extra-adrenal PGL, particularly in surgically inoperable tumours and metastatic or multifocal disease.

  12. Clinical evaluation of female pelvic tumors. Application fields of integrated PET/MRI; Lokal- und Ganzkoerperdiagnostik weiblicher Beckentumore. Anwendungsfelder der integrierten PET-MRT

    Energy Technology Data Exchange (ETDEWEB)

    Grueneisen, J.; Umutlu, L. [Universitaetsklinikum Essen, Institut fuer diagnostische und interventionelle Radiologie und Neuroradiologie, Essen (Germany)

    2016-07-15

    Integrated positron emission tomography (PET) and magnetic resonance imaging (MRI) scanning has recently become established in clinical imaging. Various studies have demonstrated the great potential of this new hybrid imaging procedure for applications in the field of oncology and the diagnostics of inflammatory processes. With initial studies demonstrating the feasibility and high diagnostic potential of PET/MRI comparable to PET-computed tomography (CT), the focus of future studies should be on the identification of application fields with a potential diagnostic benefit of PET/MRI over other established diagnostic tools. Both MRI and PET/CT are widely used in the diagnostic algorithms for malignancies of the female pelvis. A simultaneous acquisition of PET and MRI data within a single examination provides complementary information which can be used for a more comprehensive evaluation of the primary tumor as well as for whole body staging. Therefore, the aim of this article is to outline potential clinical applications of integrated PET/MRI for the diagnostic work-up of primary or recurrent gynecological neoplasms of the female pelvis. (orig.) [German] Integrierte Positronenemissionstomographie-Magnetresonanztomographen (PET-MRT) stehen seit wenigen Jahren fuer die klinische Diagnostik zur Verfuegung. Diverse Arbeiten konnten bereits das grosse Potenzial dieser neuen hybriden Bildgebungsmodalitaet zur Anwendung in der onkologischen und inflammatorischen Diagnostik aufzeigen. Nachdem initiale Studien die Durchfuehrbarkeit und diagnostische Vergleichbarkeit der PET-MRT zur etablierten PET-Computertomographie (PET-CT) gezeigt haben, sollte fuer eine Implementierung in der Routinediagnostik der Fokus zukuenftiger Studien darin liegen, eindeutige Indikationen zu definieren, in denen die simultane PET-MRT-Bildgebung einen definitiven Vorteil verglichen mit den etablierten diagnostischen Verfahren bietet. Sowohl die MRT als auch die PET-CT finden bereits eine

  13. Intraindividual comparison of F-18-FLT PET and F-18 FET PET in brain tumor patients

    International Nuclear Information System (INIS)

    Kim, Sung Eun; Cheon, G. J.; Cho, Y. S.; Kwak, H. S.; Lee, C. H.; Choi, C. W.; Lim, S. M.

    2003-01-01

    To compare findings on FLT PET with FET PET, we prospectively undertaken FLT, FET and FDG PET in same patient with suspected primary/metastatic and recurrent brain tumors. Seventeen studies in 16 patients (47 8.3 years, M: F 10: 6) with brain tumor (3 for initial diagnosis, 6 for therapeutic response, 6 for detecting recurrence, 1 for diagnosis and recurrence both) were included. Brain tumors were 14 gliomas (6 high- grade 9 low-grade by the WHO classification), 2 metastatic brain tumors and 1 CNS lymphoma. 18F-FDG, FLT and FET PET were performed within two weeks. Attenuation-corrected brain images were acquired 30 minutes after injection of 370-555 MBq FDG, FLT and FET with a dedicated PET scanner (ECAT HR scanner, Siemens-CTI). Maximum SUV (max SUV) and relative uptake defined by FLT and FET accumulation within the tumor in relation to a contralateral control region (max SUV for tumor/ mean SUV for contralateral normal gray matter) were calculated. 26 tumor foci were analyzed. Relative FLT uptake (4.17 2.4, 0.58 to 7.45) was grater than than FET uptake (2.03 1.17, 0.92 to 4.53 (p<0.0006)) and FDG uptake (1.16 0.34, 0.76 to 2.08). Among FLT, FET and FDG uptakes in 20 tumor foci, correlation were poor. the relative FLT uptake of high-grade glioma was higher than low-glioma (6.070.76 vs 3.11 2.15, p=0.002), however, relative FET uptake was not different significantly (2.68 1.51, high-grade vs 1.970.78, low-grade). The correlation between tumor grade (high vs low grade) and relative uptake (FLT and FET) was shown only with relative FLT uptake (r=0.62, p=0.002). The best cut off value of relative FLT uptake between high-grade and low-grade glioma was 4.54 (AUC: 0.89 sensitivity: 100 specificity: 86.7%). Compared with FET uptake, FLT uptake showed much higher contrast and associated with tumor grade. Further study, evaluation of proliferative index of Ki-67 and its relationship with FLT and FET uptake, are ongoing

  14. Imaging with PET system

    International Nuclear Information System (INIS)

    Das, B.K.; Noreen Norfaraheen Lee Abdullah

    2012-01-01

    PET deals with biochemistry and metabolic changes that occur at molecular level. Hence, PET differs fundamentally from other imaging modalities. CT imaging is based on tissue density, whereas MRI conveys anatomic information based on proton density and proton relaxation dynamics. CT and MRI are useful in clinical diagnosis only when disease process has caused significant anatomic alterations. However, in most disease conditions chemical changes precede anatomic changes, that can be detected by PET technology. Thus, PET can provide earliest and unique information about ongoing disease process long before anatomic or structural changes take place. There is no other modality available at present that can replace PET technology. Although PET produces cross-sectional images like that obtained in MRI or CT, they represent circulation, function and metabolism, and not anatomic structure. PET is extremely sensitive measuring quantitatively concentration of tracers in nano to pico-molar range. Thus, PET enables merger of biochemistry and biology in medicine giving birth to molecular medicine that focuses on identifying the molecular errors of disease leading to developing molecular corrections including gene therapy. Molecular imaging with PET has been playing a role in examining the biological nature of a disease condition and its characterization to guide selection and evaluation of treatment. (author)

  15. Diagnostic accuracy of {sup 18}F-FDG-PET and PET/CT in patients with Ewing sarcoma family tumours: a systematic review and a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Treglia, Giorgio [Institute of Nuclear Medicine, Catholic University of the Sacred Heart, Department of Bioimaging and Radiological Sciences, Rome (Italy); Institute of Nuclear Medicine, Positron Emission Tomography Centre, Catholic University of the Sacred Heart, Department of Bioimaging and Radiological Sciences, Rome (Italy); Salsano, Marco; Stefanelli, Antonella; Mattoli, Maria Vittoria; Giordano, Alessandro [Institute of Nuclear Medicine, Catholic University of the Sacred Heart, Department of Bioimaging and Radiological Sciences, Rome (Italy); Bonomo, Lorenzo [Institute of Radiology, Catholic University of the Sacred Heart, Department of Bioimaging and Radiological Sciences, Rome (Italy)

    2012-03-15

    To systematically review and meta-analyse literature data on the diagnostic performance of fluorine-18-fluorodeoxyglucose (FDG) positron emission tomography (PET) and positron emission tomography/computed tomography (PET/CT) in patients with Ewing sarcoma family tumours (ESFT). PubMed/MEDLINE, Embase and Scopus databases were searched for articles that evaluated FDG-PET and PET/CT in patients with ESFT from inception to 31 May 2011. Studies that fulfilled the three following criteria were included in the systematic review: FDG-PET or PET/CT performed in patients with ESFT; articles about the diagnostic accuracy of FDG-PET and PET/CT; sample size of at least 10 patients with ESFT were included. Studies in which there were sufficient data to reassess sensitivity and specificity of FDG-PET or PET/CT in ESFT were included in the meta-analysis, excluding duplicate publications. Finally, pooled sensitivity, pooled specificity and area under the receiver operating characteristic (ROC) curve of FDG-PET or PET/CT in ESFT were calculated. We found 13 studies comprising a total of 342 patients with ESFT. The main findings of the studies included are presented. The meta-analysis of five selected studies provided these results about FDG-PET and PET/CT in ESFT: pooled sensitivity: 96% (95% confidence interval [CI] 91-99%); pooled specificity: 92% (95% CI 87-96%); area under the ROC curve: 0.97. With regard to the staging and restaging of patients with ESFT, the sensitivity, specificity and accuracy of FDG-PET and PET/CT are high; the combination of FDG-PET or PET/CT with conventional imaging is a valuable tool for the staging and restaging of ESFT and has a relevant impact on the treatment strategy plan. (orig.)

  16. Cost-effectiveness of PET and PET/Computed Tomography

    DEFF Research Database (Denmark)

    Gerke, Oke; Hermansson, Ronnie; Hess, Søren

    2015-01-01

    measure by means of incremental cost-effectiveness ratios when considering the replacement of the standard regimen by a new diagnostic procedure. This article discusses economic assessments of PET and PET/computed tomography reported until mid-July 2014. Forty-seven studies on cancer and noncancer...

  17. Performance of a high sensitivity time-of-flight PET ring operating simultaneously within a 3T MR system

    International Nuclear Information System (INIS)

    Levin, Craig S; Jansen, Floris; Deller, Tim; Maramraju, Sri Harsha; Grant, Alex; Iagaru, Andrei

    2014-01-01

    A time-of-flight (TOF)-PET/MR research system installed at Stanford will be used to test the hypotheses that (a) it is possible to acquire simultaneous TOF-PET and 3T MR data while achieving uncompromised performance in both modalities and (b) simultaneous TOF-PET/MR is a tool for multi-parameter characterization of disease. In this paper we will describe the design as well as performance measurements both for the standalone PET ring, and with the two systems integrated. We will also show a selection of clinical images to compare the performance of the integrated TOF-PET/MR system with that of a state-of-the-art PET/CT system.

  18. Comparison of Imaging Characteristics of 124I PET for Determination of Optimal Energy Window on the Siemens Inveon PET

    Directory of Open Access Journals (Sweden)

    A Ram Yu

    2016-01-01

    Full Text Available Purpose.124I has a half-life of 4.2 days, which makes it suitable for imaging over several days over its uptake and washout phases. However, it has a low positron branching ratio (23%, because of prompt gamma coincidence due to high-energy γ-photons (602 to 1,691 keV, which are emitted in cascade with positrons. Methods. In this study, we investigated the optimal PET energy window for 124I PET based on image characteristics of reconstructed PET. Image characteristics such as nonuniformities, recovery coefficients (RCs, and the spillover ratios (SORs of 124I were measured as described in NEMA NU 4-2008 standards. Results. The maximum and minimum prompt gamma coincidence fraction (PGF were 33% and 2% in 350~800 and 400~590 keV, respectively. The difference between best and worst uniformity in the various energy windows was less than 1%. The lowest SORs of 124I were obtained at 350~750 keV in nonradioactive water compartment. Conclusion. Optimal energy window should be determined based on image characteristics. Our developed correction method would be useful for the correction of high-energy prompt gamma photon in 124I PET. In terms of the image quality of 124I PET, our findings indicate that an energy window of 350~750 keV would be optimal.

  19. {sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

    Energy Technology Data Exchange (ETDEWEB)

    Carlier, Thomas, E-mail: thomas.carlier@chu-nantes.fr [Department of Nuclear Medicine, University Hospital of Nantes, Place Alexis Ricordeau, Nantes 44093, France and CRCNA–UMR 892 INSERM 6299 CNRS, 8 quai Moncousu BP 70721, Nantes 44007 (France); Willowson, Kathy P. [Institute of Medical Physics, University of Sydney, Camperdown, New South Wales 2006 (Australia); Fourkal, Eugene [Department of Radiation Oncology, Allegheny General Hospital, Pittsburgh, Pennsylvania 15212 (United States); Bailey, Dale L. [Faculty of Health Sciences, University of Sydney, Lidcombe 2141, Australia and Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, New South Wales 2065 (Australia); Doss, Mohan [Department of Diagnostic Imaging, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States); Conti, Maurizio [Siemens Healthcare Molecular Imaging, 810 Innovation Drive, Knoxville, Tennessee 37932 (United States)

    2015-07-15

    Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely

  20. Hybrid FDG-PET/MR compared to FDG-PET/CT in adult lymphoma patients.

    Science.gov (United States)

    Atkinson, Wendy; Catana, Ciprian; Abramson, Jeremy S; Arabasz, Grae; McDermott, Shanaugh; Catalano, Onofrio; Muse, Victorine; Blake, Michael A; Barnes, Jeffrey; Shelly, Martin; Hochberg, Ephraim; Rosen, Bruce R; Guimaraes, Alexander R

    2016-07-01

    The goal of this study is to evaluate the diagnostic performance of simultaneous FDG-PET/MR including diffusion compared to FDG-PET/CT in patients with lymphoma. Eighteen patients with a confirmed diagnosis of non-Hodgkin's (NHL) or Hodgkin's lymphoma (HL) underwent an IRB-approved, single-injection/dual-imaging protocol consisting of a clinical FDG-PET/CT and subsequent FDG-PET/MR scan. PET images from both modalities were reconstructed iteratively. Attenuation correction was performed using low-dose CT data for PET/CT and Dixon-MR sequences for PET/MR. Diffusion-weighted imaging was performed. SUVmax was measured and compared between modalities and the apparent diffusion coefficient (ADC) using ROI analysis by an experienced radiologist using OsiriX. Strength of correlation between variables was measured using the Pearson correlation coefficient (r p). Of the 18 patients included in this study, 5 had HL and 13 had NHL. The median age was 51 ± 14.8 years. Sixty-five FDG-avid lesions were identified. All FDG-avid lesions were visible with comparable contrast, and therefore initial and follow-up staging was identical between both examinations. SUVmax from FDG-PET/MR [(mean ± sem) (21.3 ± 2.07)] vs. FDG-PET/CT (mean 23.2 ± 2.8) demonstrated a strongly positive correlation [r s = 0.95 (0.94, 0.99); p < 0.0001]. There was no correlation found between ADCmin and SUVmax from FDG-PET/MR [r = 0.17(-0.07, 0.66); p = 0.09]. FDG-PET/MR offers an equivalent whole-body staging examination as compared with PET/CT with an improved radiation safety profile in lymphoma patients. Correlation of ADC to SUVmax was weak, understating their lack of equivalence, but not undermining their potential synergy and differing importance.